WorldWideScience

Sample records for rapid method based

  1. Rapid culture-based methods for drug-resistance detection in Mycobacterium tuberculosis.

    Science.gov (United States)

    Palomino, Juan Carlos; Martin, Anandi; Von Groll, Andrea; Portaels, Francoise

    2008-10-01

    Tuberculosis still represents a major public health problem, especially in low-resource countries where the burden of the disease is more important. Multidrug-resistant and extensively drug drug-resistant tuberculosis constitute serious problems for the efficient control of the disease stressing the need to investigate resistance to first- and second-line drugs. Conventional methods for detecting drug-resistance in Mycobacterium tuberculosis are slow and cumbersome. The most commonly used proportion method on Löwenstein-Jensen medium or Middlebrook agar requires a minimum of 3-4 weeks to produce results. Several new approaches have been proposed in the last years for the rapid and timely detection of drug-resistance in tuberculosis. This review will address phenotypic culture-based methods for rapid drug susceptibility testing in M. tuberculosis.

  2. 3D virtual human rapid modeling method based on top-down modeling mechanism

    Directory of Open Access Journals (Sweden)

    LI Taotao

    2017-01-01

    Full Text Available Aiming to satisfy the vast custom-made character demand of 3D virtual human and the rapid modeling in the field of 3D virtual reality, a new virtual human top-down rapid modeling method is put for-ward in this paper based on the systematic analysis of the current situation and shortage of the virtual hu-man modeling technology. After the top-level realization of virtual human hierarchical structure frame de-sign, modular expression of the virtual human and parameter design for each module is achieved gradu-al-level downwards. While the relationship of connectors and mapping restraints among different modules is established, the definition of the size and texture parameter is also completed. Standardized process is meanwhile produced to support and adapt the virtual human top-down rapid modeling practice operation. Finally, the modeling application, which takes a Chinese captain character as an example, is carried out to validate the virtual human rapid modeling method based on top-down modeling mechanism. The result demonstrates high modelling efficiency and provides one new concept for 3D virtual human geometric mod-eling and texture modeling.

  3. A new alginate-based rapid method for determining coliforms in milk.

    Science.gov (United States)

    Chang, Su-sen; Gray, Peter M; Woo, Gun-Jo; Kang, Dong-Hyun

    2003-11-01

    A new rapid method for monitoring coliforms was developed on the basis of the instant gelling effects of alginate and calcium. The effectiveness of this new method in the detection of coliforms was evaluated. Tests involving Escherichia coli, Enterobacter cloacae, Klebsiella pneumoniae, total coliforms in milk, cold-injured coliforms, and total coliforms in raw milk were carried out. The bacterial samples were diluted in 0.2% peptone water containing 90 mM CaCl2 and added into test tubes containing modified purple broth base medium. Coliform concentrations were determined on the basis of the time of color change and gas production in the alginate tubes. All results obtained by the alginate method correlated strongly with those obtained by the conventional violet red bile agar (VRBA) plating method. The alginate method reduced detection time by 12 to 14 h compared with the conventional VRBA plating method. The alginate method can be applied in field studies more easily than melted-agar systems can. The results of this study indicate that the alginate method is an accurate, rapid, simple, and economical way to monitor and estimate concentrations of total coliforms in food.

  4. A rapid and direct real time PCR-based method for identification of Salmonella spp

    DEFF Research Database (Denmark)

    Rodriguez-Lazaro, D.; Hernández, Marta; Esteve, T.

    2003-01-01

    The aim of this work was the validation of a rapid, real-time PCR assay based on TaqMan((R)) technology for the unequivocal identification of Salmonella spp. to be used directly on an agar-grown colony. A real-time PCR system targeting at the Salmonella spp. invA gene was optimized and validated...... to be especially convenient because the pre-mix containing all PCR reagents except for the bacterial cells could be kept at -20 degreesC for at least I month before its use. The optimized TaqMan((R)) real-time PCR assay is a useful, simple and rapid method for routine identification of Salmonella spp...

  5. A tree-based method for the rapid screening of chemical fingerprints

    Directory of Open Access Journals (Sweden)

    Pedersen Christian NS

    2010-01-01

    Full Text Available Abstract Background The fingerprint of a molecule is a bitstring based on its structure, constructed such that structurally similar molecules will have similar fingerprints. Molecular fingerprints can be used in an initial phase of drug development for identifying novel drug candidates by screening large databases for molecules with fingerprints similar to a query fingerprint. Results In this paper, we present a method which efficiently finds all fingerprints in a database with Tanimoto coefficient to the query fingerprint above a user defined threshold. The method is based on two novel data structures for rapid screening of large databases: the kD grid and the Multibit tree. The kD grid is based on splitting the fingerprints into k shorter bitstrings and utilising these to compute bounds on the similarity of the complete bitstrings. The Multibit tree uses hierarchical clustering and similarity within each cluster to compute similar bounds. We have implemented our method and tested it on a large real-world data set. Our experiments show that our method yields approximately a three-fold speed-up over previous methods. Conclusions Using the novel kD grid and Multibit tree significantly reduce the time needed for searching databases of fingerprints. This will allow researchers to (1 perform more searches than previously possible and (2 to easily search large databases.

  6. FLASH: A rapid method for prototyping paper-based microfluidic devices‡

    Science.gov (United States)

    Martinez, Andres W.; Phillips, Scott T.; Wiley, Benjamin J.; Gupta, Malancha

    2011-01-01

    This article describes FLASH (Fast Lithographic Activation of Sheets), a rapid method for laboratory prototyping of microfluidic devices in paper. Paper-based microfluidic devices are emerging as a new technology for applications in diagnostics for the developing world, where low cost and simplicity are essential. FLASH is based on photolithography, but requires only a UV lamp and a hotplate; no clean-room or special facilities are required (FLASH patterning can even be performed in sunlight if a UV lamp and hotplate are unavailable). The method provides channels in paper with dimensions as small as 200 μm in width and 70 μm in height; the height is defined by the thickness of the paper. Photomasks for patterning paper-based microfluidic devices can be printed using an ink-jet printer or photocopier, or drawn by hand using a waterproof black pen. FLASH provides a straightforward method for prototyping paper-based microfluidic devices in regions where the technological support for conventional photolithography is not available. PMID:19023478

  7. Rapid and Sensitive Lateral Flow Immunoassay Method for Procalcitonin (PCT Based on Time-Resolved Immunochromatography

    Directory of Open Access Journals (Sweden)

    Xiang-Yang Shao

    2017-02-01

    Full Text Available Procalcitonin (PCT is a current, frequently-used marker for severe bacterial infection. The aim of this study was to develop a cost-effective detection kit for rapid quantitative and on-site detection of PCT. To develop the new PCT quantitative detecting kit, a double-antibody sandwich immunofluorescent assay was employed based on time-resolved immunofluorescent assay (TRFIA combined with lateral flow immunoassay (LFIA. The performance of the new developed kit was evaluated in the aspects of linearity, precision, accuracy, and specificity. Two-hundred thirty-four serum samples were enrolled to carry out the comparison test. The new PCT quantitative detecting kit exhibited a higher sensitivity (0.08 ng/mL. The inter-assay coefficient of variation (CV and the intra-assay CV were 5.4%–7.7% and 5.7%–13.4%, respectively. The recovery rates ranged from 93% to 105%. Furthermore, a high correlation (n = 234, r = 0.977, p < 0.0001 and consistency (Kappa = 0.875 were obtained when compared with the PCT kit from Roche Elecsys BRAHMS. Thus, the new quantitative method for detecting PCT has been successfully established. The results indicated that the newly-developed system based on TRFIA combined with LFIA was suitable for rapid and on-site detection for PCT, which might be a useful platform for other biomarkers in point-of-care tests.

  8. Validity and feasibility of a satellite imagery-based method for rapid estimation of displaced populations

    Directory of Open Access Journals (Sweden)

    Checchi Francesco

    2013-01-01

    Full Text Available Abstract Background Estimating the size of forcibly displaced populations is key to documenting their plight and allocating sufficient resources to their assistance, but is often not done, particularly during the acute phase of displacement, due to methodological challenges and inaccessibility. In this study, we explored the potential use of very high resolution satellite imagery to remotely estimate forcibly displaced populations. Methods Our method consisted of multiplying (i manual counts of assumed residential structures on a satellite image and (ii estimates of the mean number of people per structure (structure occupancy obtained from publicly available reports. We computed population estimates for 11 sites in Bangladesh, Chad, Democratic Republic of Congo, Ethiopia, Haiti, Kenya and Mozambique (six refugee camps, three internally displaced persons’ camps and two urban neighbourhoods with a mixture of residents and displaced ranging in population from 1,969 to 90,547, and compared these to “gold standard” reference population figures from census or other robust methods. Results Structure counts by independent analysts were reasonably consistent. Between one and 11 occupancy reports were available per site and most of these reported people per household rather than per structure. The imagery-based method had a precision relative to reference population figures of Conclusions In settings with clearly distinguishable individual structures, the remote, imagery-based method had reasonable accuracy for the purposes of rapid estimation, was simple and quick to implement, and would likely perform better in more current application. However, it may have insurmountable limitations in settings featuring connected buildings or shelters, a complex pattern of roofs and multi-level buildings. Based on these results, we discuss possible ways forward for the method’s development.

  9. A novel method for ATLAS FSI alignment based on rapid, direct phase monitoring

    CERN Document Server

    Gibson, S M; The ATLAS collaboration; Horton, K; Lewis, A; Liang, Z; Livermore, S; Mattravers, C; Nickerson, R B

    2010-01-01

    Frequency Scanning Interferometry is a precise, multiple distance measurement technique, originally developed for ATLAS, which is suited to a variety of applications in the survey and alignment of future accelerators and particle detectors. The ATLAS inner detector is instrumented with an automated FSI alignment system, capable of simultaneously measuring hundreds of interferometers within the operational particle tracker. The alignment system began data taking in 2008 and we present the latest results from the on-detector system during LHC running. A new method has been developed based on rapid, direct monitoring of the interferometer phase, which allows the measurement of short term motions with improved precision, at a fraction of the wavelength of light (typically sensitive to < 50 nm). We outline the theory behind this novel technique and demonstrate precise measurements from ATLAS, which reveal interesting micron-level movements of the inner detector, correlated with thermal cycles and magnetic f...

  10. Improved Savitzky-Golay-method-based fluorescence subtraction algorithm for rapid recovery of Raman spectra.

    Science.gov (United States)

    Chen, Kun; Zhang, Hongyuan; Wei, Haoyun; Li, Yan

    2014-08-20

    In this paper, we propose an improved subtraction algorithm for rapid recovery of Raman spectra that can substantially reduce the computation time. This algorithm is based on an improved Savitzky-Golay (SG) iterative smoothing method, which involves two key novel approaches: (a) the use of the Gauss-Seidel method and (b) the introduction of a relaxation factor into the iterative procedure. By applying a novel successive relaxation (SG-SR) iterative method to the relaxation factor, additional improvement in the convergence speed over the standard Savitzky-Golay procedure is realized. The proposed improved algorithm (the RIA-SG-SR algorithm), which uses SG-SR-based iteration instead of Savitzky-Golay iteration, has been optimized and validated with a mathematically simulated Raman spectrum, as well as experimentally measured Raman spectra from non-biological and biological samples. The method results in a significant reduction in computing cost while yielding consistent rejection of fluorescence and noise for spectra with low signal-to-fluorescence ratios and varied baselines. In the simulation, RIA-SG-SR achieved 1 order of magnitude improvement in iteration number and 2 orders of magnitude improvement in computation time compared with the range-independent background-subtraction algorithm (RIA). Furthermore the computation time of the experimentally measured raw Raman spectrum processing from skin tissue decreased from 6.72 to 0.094 s. In general, the processing of the SG-SR method can be conducted within dozens of milliseconds, which can provide a real-time procedure in practical situations.

  11. Novel methods for improving rapid paper-based protein assays with gold nanoparticle detection

    OpenAIRE

    Lama, Lara

    2017-01-01

    This thesis describes methods for improving sensitivity in rapid singleplex and multiplex microarray assays. The assays utilize the optical characteristics of colloidal gold nanoparticles for the colorimetric detection of proteins. Multiplexed detection in sandwich immunoassays is limited by cross-reactivity between different detection antibodies. The cross-reactivity between antibodies can contribute to increased background noise - decreasing the Limit-of-Detection of the assay - or generate...

  12. Rapid method for simulating gas spectra using reversed PCR temperature calibration models based on Hitran data

    DEFF Research Database (Denmark)

    Bak, J.

    1999-01-01

    A computer program was produced to make rapid simulations of CO gas spectra at a spectral resolution of 1 cm(-1) and at temperatures ranging from 295 to 845 K and concentrations from 5 to 400 mg/m(3). The program is based on loadings and scores from three principal component regression (PCR) temp...... a uniform slab of gas at various temperatures, concentrations, and pathlengths. The gain in speed of the calculations of the spectra is based on the fact that the PCR models include mathematical pretreatments and compress the data effectively.......A computer program was produced to make rapid simulations of CO gas spectra at a spectral resolution of 1 cm(-1) and at temperatures ranging from 295 to 845 K and concentrations from 5 to 400 mg/m(3). The program is based on loadings and scores from three principal component regression (PCR......) temperature calibration models. Three sets of 12 Hitran-simulated high-density spectra, each set spanning the entire temperature range at constant concentrations (50, 150, and 300 mg/m(3)), were used as calibration spectra in the PCR temperature models. All the spectra were convoluted with a sine...

  13. A rapid sonication based method for preparation of stromal vascular fraction and mesenchymal stem cells from fat tissue

    Directory of Open Access Journals (Sweden)

    Mohammad Amir Amirkhani

    2016-06-01

    Conclusion: The current protocol based on the sonication-mediated cavitation is a rapid, safe and cost-effective method, which is proposed for isolation of SVF and of course ADSCs cultures in a large scale for the clinical trials or therapeutic purposes.

  14. Rapid and Sensitive Lateral Flow Immunoassay Method for Procalcitonin (PCT) Based on Time-Resolved Immunochromatography.

    Science.gov (United States)

    Shao, Xiang-Yang; Wang, Cong-Rong; Xie, Chun-Mei; Wang, Xian-Guo; Liang, Rong-Liang; Xu, Wei-Wen

    2017-02-28

    Procalcitonin (PCT) is a current, frequently-used marker for severe bacterial infection. The aim of this study was to develop a cost-effective detection kit for rapid quantitative and on-site detection of PCT. To develop the new PCT quantitative detecting kit, a double-antibody sandwich immunofluorescent assay was employed based on time-resolved immunofluorescent assay (TRFIA) combined with lateral flow immunoassay (LFIA). The performance of the new developed kit was evaluated in the aspects of linearity, precision, accuracy, and specificity. Two-hundred thirty-four serum samples were enrolled to carry out the comparison test. The new PCT quantitative detecting kit exhibited a higher sensitivity (0.08 ng/mL). The inter-assay coefficient of variation (CV) and the intra-assay CV were 5.4%-7.7% and 5.7%-13.4%, respectively. The recovery rates ranged from 93% to 105%. Furthermore, a high correlation ( n = 234, r = 0.977, p LFIA was suitable for rapid and on-site detection for PCT, which might be a useful platform for other biomarkers in point-of-care tests.

  15. A Rapid Coordinate Transformation Method Applied in Industrial Robot Calibration Based on Characteristic Line Coincidence

    Directory of Open Access Journals (Sweden)

    Bailing Liu

    2016-02-01

    Full Text Available Coordinate transformation plays an indispensable role in industrial measurements, including photogrammetry, geodesy, laser 3-D measurement and robotics. The widely applied methods of coordinate transformation are generally based on solving the equations of point clouds. Despite the high accuracy, this might result in no solution due to the use of ill conditioned matrices. In this paper, a novel coordinate transformation method is proposed, not based on the equation solution but based on the geometric transformation. We construct characteristic lines to represent the coordinate systems. According to the space geometry relation, the characteristic line scan is made to coincide by a series of rotations and translations. The transformation matrix can be obtained using matrix transformation theory. Experiments are designed to compare the proposed method with other methods. The results show that the proposed method has the same high accuracy, but the operation is more convenient and flexible. A multi-sensor combined measurement system is also presented to improve the position accuracy of a robot with the calibration of the robot kinematic parameters. Experimental verification shows that the position accuracy of robot manipulator is improved by 45.8% with the proposed method and robot calibration.

  16. Rapid Retrieval of Lung Nodule CT Images Based on Hashing and Pruning Methods

    Directory of Open Access Journals (Sweden)

    Ling Pan

    2016-01-01

    Full Text Available The similarity-based retrieval of lung nodule computed tomography (CT images is an important task in the computer-aided diagnosis of lung lesions. It can provide similar clinical cases for physicians and help them make reliable clinical diagnostic decisions. However, when handling large-scale lung images with a general-purpose computer, traditional image retrieval methods may not be efficient. In this paper, a new retrieval framework based on a hashing method for lung nodule CT images is proposed. This method can translate high-dimensional image features into a compact hash code, so the retrieval time and required memory space can be reduced greatly. Moreover, a pruning algorithm is presented to further improve the retrieval speed, and a pruning-based decision rule is presented to improve the retrieval precision. Finally, the proposed retrieval method is validated on 2,450 lung nodule CT images selected from the public Lung Image Database Consortium (LIDC database. The experimental results show that the proposed pruning algorithm effectively reduces the retrieval time of lung nodule CT images and improves the retrieval precision. In addition, the retrieval framework is evaluated by differentiating benign and malignant nodules, and the classification accuracy can reach 86.62%, outperforming other commonly used classification methods.

  17. Rapid Retrieval of Lung Nodule CT Images Based on Hashing and Pruning Methods.

    Science.gov (United States)

    Pan, Ling; Qiang, Yan; Yuan, Jie; Wu, Lidong

    2016-01-01

    The similarity-based retrieval of lung nodule computed tomography (CT) images is an important task in the computer-aided diagnosis of lung lesions. It can provide similar clinical cases for physicians and help them make reliable clinical diagnostic decisions. However, when handling large-scale lung images with a general-purpose computer, traditional image retrieval methods may not be efficient. In this paper, a new retrieval framework based on a hashing method for lung nodule CT images is proposed. This method can translate high-dimensional image features into a compact hash code, so the retrieval time and required memory space can be reduced greatly. Moreover, a pruning algorithm is presented to further improve the retrieval speed, and a pruning-based decision rule is presented to improve the retrieval precision. Finally, the proposed retrieval method is validated on 2,450 lung nodule CT images selected from the public Lung Image Database Consortium (LIDC) database. The experimental results show that the proposed pruning algorithm effectively reduces the retrieval time of lung nodule CT images and improves the retrieval precision. In addition, the retrieval framework is evaluated by differentiating benign and malignant nodules, and the classification accuracy can reach 86.62%, outperforming other commonly used classification methods.

  18. Rapid assessment of insect fauna based on local knowledge: comparing ecological and ethnobiological methods.

    Science.gov (United States)

    Lima, Daniele Cristina de Oliveira; Ramos, Marcelo Alves; da Silva, Henrique Costa Hermenegildo; Alves, Angelo Giuseppe Chaves

    2016-03-01

    The rapid assessment of biodiversity making use of surveys of local knowledge has been successful for different biological taxa. However, there are no reports on the testing of such tools for sampling insect fauna. The present study aimed to evaluate the efficiency of different ethnobiological techniques for rapid sampling of insect fauna. Field research for the conventional survey of insect fauna was conducted on a private farm (9 ° 43'38.95 "S, 37 ° 45'11.97" W) , where there was intensive cultivation of okra (Abelmoschus esculentus L. (Moench)). The survey of local entomological knowledge was conducted among all the producers of okra living in the rural villages Pereira, Santa Luzia, and Nassau de Souza, within the Jacaré Curituba irrigated settlement scheme. The combined use of the techniques "free list" and projective interviews was analyzed, using two types of visual stimuli: stock photos and an entomological box. During the conventional survey of insect fauna, the species Bemisia tabaci biotype B, Aphis gossypii, Phenacoccus sp., Icerya purchasi and Lagria villosa were the primary pests found in the okra crop. Regarding the survey of insect pests, the results were convergent  in both techniques (conventional sampling and free list). Comparing the interview with visual stimuli (pictures) and specimen witnesses (entomological box) revealed that the latter was more effective. Techniques based on the recording and analysis of local knowledge about insects are effective for quick sampling of pest insects, but ineffective in sampling predator insects. The utilization of collected insects, infested branches, or photos of the symptoms of damage caused by pests in projective interviews is recommended.

  19. Exploration and practice of methods and processes of evidence-based rapid review on peer review of WHO EML application.

    Science.gov (United States)

    Li, Youping; Yu, Jiajie; Du, Liang; Sun, Xin; Kwong, Joey S W; Wu, Bin; Hu, Zhiqiang; Lu, Jing; Xu, Ting; Zhang, Lingli

    2015-11-01

    After 38 years of development, the procedure of selection and evaluation of the World Health Organization Essential Medicine List (WHO EML) is increasingly scientific and formal. However, peer review for the applications of World Health Organization Essential Medicine List is always required in a short period. It is necessary to build up a set of methods and processes for rapid review. We identified the process of evidenced-based rapid review on WHO EML application for peer reviews according to 11 items which were required during reporting of the peer review results of the proposals. The most important items for the rapid review of World Health Organization Essential Medicine List peer reviewers are (1) to confirm the requirements and identify the purposes; (2) to establish the research questions and translate the questions into the 'Participants, Interventions, Comparators, Outcomes, Study design' (PICOS) format; (3) to search and screen available evidence, for which high-level evidence is preferred, such as systematic reviews or meta-analyses, health technology assessment, clinical guidelines; (4) to extract data, where we extract primary information based on the purposes; (5) to synthesize data by qualitative methods, assess the quality of evidence, and compare the results; (6) to provide the answers to the applications, quality of evidences and strength of recommendations. Our study established a set of methods and processes for the rapid review of World Health Organization Essential Medicine List peer review, and our findings were used to guide the reviewers to fulfill the 19(th) World Health Organization Essential Medicine List peer review. The methods and processes were feasible and met the necessary requirements in terms of time and quality. Continuous improvement and evaluation in practice are warranted. © 2015 Chinese Cochrane Center, West China Hospital of Sichuan University and Wiley Publishing Asia Pty Ltd.

  20. Rapid and tunable method to temporally control gene editing based on conditional Cas9 stabilization.

    Science.gov (United States)

    Senturk, Serif; Shirole, Nitin H; Nowak, Dawid G; Corbo, Vincenzo; Pal, Debjani; Vaughan, Alexander; Tuveson, David A; Trotman, Lloyd C; Kinney, Justin B; Sordella, Raffaella

    2017-02-22

    The CRISPR/Cas9 system is a powerful tool for studying gene function. Here, we describe a method that allows temporal control of CRISPR/Cas9 activity based on conditional Cas9 destabilization. We demonstrate that fusing an FKBP12-derived destabilizing domain to Cas9 (DD-Cas9) enables conditional Cas9 expression and temporal control of gene editing in the presence of an FKBP12 synthetic ligand. This system can be easily adapted to co-express, from the same promoter, DD-Cas9 with any other gene of interest without co-modulation of the latter. In particular, when co-expressed with inducible Cre-ER T2 , our system enables parallel, independent manipulation of alleles targeted by Cas9 and traditional recombinase with single-cell specificity. We anticipate this platform will be used for the systematic characterization and identification of essential genes, as well as the investigation of the interactions between functional genes.

  1. Rapid detection of Salmonella in pet food: design and evaluation of integrated methods based on real-time PCR detection.

    Science.gov (United States)

    Balachandran, Priya; Friberg, Maria; Vanlandingham, V; Kozak, K; Manolis, Amanda; Brevnov, Maxim; Crowley, Erin; Bird, Patrick; Goins, David; Furtado, Manohar R; Petrauskene, Olga V; Tebbs, Robert S; Charbonneau, Duane

    2012-02-01

    Reducing the risk of Salmonella contamination in pet food is critical for both companion animals and humans, and its importance is reflected by the substantial increase in the demand for pathogen testing. Accurate and rapid detection of foodborne pathogens improves food safety, protects the public health, and benefits food producers by assuring product quality while facilitating product release in a timely manner. Traditional culture-based methods for Salmonella screening are laborious and can take 5 to 7 days to obtain definitive results. In this study, we developed two methods for the detection of low levels of Salmonella in pet food using real-time PCR: (i) detection of Salmonella in 25 g of dried pet food in less than 14 h with an automated magnetic bead-based nucleic acid extraction method and (ii) detection of Salmonella in 375 g of composite dry pet food matrix in less than 24 h with a manual centrifugation-based nucleic acid preparation method. Both methods included a preclarification step using a novel protocol that removes food matrix-associated debris and PCR inhibitors and improves the sensitivity of detection. Validation studies revealed no significant differences between the two real-time PCR methods and the standard U.S. Food and Drug Administration Bacteriological Analytical Manual (chapter 5) culture confirmation method.

  2. Rapid deletion plasmid construction methods for protoplast and Agrobacterium based fungal transformation systems

    Science.gov (United States)

    Increasing availability of genomic data and sophistication of analytical methodology in fungi has elevated the need for functional genomics tools in these organisms. Gene deletion is a critical tool for functional analysis. The targeted deletion of genes requires both a suitable method for the trans...

  3. Loop-mediated isothermal amplification (LAMP)-based method for rapid mushroom species identification.

    Science.gov (United States)

    Vaagt, Franziska; Haase, Ilka; Fischer, Markus

    2013-02-27

    Toxic mushroom species, such as the death cap ( Amanita phalloides ), are responsible for most mushroom poisonings. In the present work, novel loop-mediated isothermal amplification (LAMP) assays were used for the differentiation of even closely related edible and toxic mushroom species. The applicability of these methods was tested by cross-reaction studies and analysis of spiked mushroom samples (raw and fried material). Contaminations at the level of 2% (w/w) could be detected in different mushroom blends. Three detection methods were used: agarose gel analysis, fluorimetric real-time detection, and visual detection by lateral flow dipsticks (LFD). The LAMP assay combined with LFD detection allows the identification of A. phalloides in about 2 h (including DNA extraction) at a very low level of technical equipment (micropestle, water bath, and mobile centrifuge), which makes this technique perfectly suited for on-site applications.

  4. Accurate and rapid optical characterization of an anisotropic guided structure based on a neural method.

    Science.gov (United States)

    Robert, Stéphane; Battie, Yann; Jamon, Damien; Royer, Francois

    2007-04-10

    Optimal performances of integrated optical devices are obtained by the use of an accurate and reliable characterization method. The parameters of interest, i.e., optical indices and thickness of the waveguide structure, are calculated from effective indices by means of an inversion procedure. We demonstrate how an artificial neural network can achieve such a process. The artificial neural network used is a multilayer perceptron. The first result concerns a simulated anisotropic waveguide. The accuracy in the determination of optical indices and waveguide thickness is 5 x 10(-5) and 4 nm, respectively. Then an experimental application on a silica-titania thin film is performed. In addition, effective indices are measured by m-lines spectroscopy. Finally, a comparison with a classical optimization algorithm demonstrates the robustness of the neural method.

  5. A tree based method for the rapid screening of chemical fingerprints

    DEFF Research Database (Denmark)

    Kristensen, Thomas Greve; Nielsen, Jesper; Pedersen, Christian Nørgaard Storm

    2009-01-01

    The fingerprint of a molecule is a bitstring based on its structure, constructed such that structurally similar molecules will have similar fingerprints. Molecular fingerprints can be used in an initial phase for identifying novel drug candidates by screening large databases for molecules...

  6. Rapid identification of Mycobacterium tuberculosis infection by a new array format-based surface plasmon resonance method

    Science.gov (United States)

    Hsieh, Shang-Chen; Chang, Chia-Chen; Lu, Chia-Chen; Wei, Chia-Fong; Lin, Chuan-Sheng; Lai, Hsin-Chih; Lin, Chii-Wann

    2012-03-01

    Tubercle bacillus [TB] is one of the most important chronic infectious diseases that cause millions of deaths annually. While conventional smear microscopy and culture methods are widely used for diagnosis of TB, the former is insensitive, and the latter takes up to 6 to 8 weeks to provide a result, limiting the value of these methods in aiding diagnosis and intermediate decisions on treatment. Therefore, a rapid detection method is essential for the diagnosis, prognosis assessment, and recurrence monitoring. A new surface plasmon resonance [SPR] biosensor based on an array format, which allowed immobilizing nine TB antigens onto the sensor chip, was constructed. Simultaneous determination of multiple TB antibodies in serum had been accomplished with this array-based SPR system. The results were compared with enzyme-linked immunosorbent assay, a conventional immunological method. Array-based SPR showed more advantages in providing label-free and real-time detection. Additionally, the high sensitivity and specificity for the detection of TB infection showed its potential for future development of biosensor arrays for TB diagnosis.

  7. A Rapid Identification Method for Calamine Using Near-Infrared Spectroscopy Based on Multi-Reference Correlation Coefficient Method and Back Propagation Artificial Neural Network.

    Science.gov (United States)

    Sun, Yangbo; Chen, Long; Huang, Bisheng; Chen, Keli

    2017-07-01

    As a mineral, the traditional Chinese medicine calamine has a similar shape to many other minerals. Investigations of commercially available calamine samples have shown that there are many fake and inferior calamine goods sold on the market. The conventional identification method for calamine is complicated, therefore as a result of the large scale of calamine samples, a rapid identification method is needed. To establish a qualitative model using near-infrared (NIR) spectroscopy for rapid identification of various calamine samples, large quantities of calamine samples including crude products, counterfeits and processed products were collected and correctly identified using the physicochemical and powder X-ray diffraction method. The NIR spectroscopy method was used to analyze these samples by combining the multi-reference correlation coefficient (MRCC) method and the error back propagation artificial neural network algorithm (BP-ANN), so as to realize the qualitative identification of calamine samples. The accuracy rate of the model based on NIR and MRCC methods was 85%; in addition, the model, which took comprehensive multiple factors into consideration, can be used to identify crude calamine products, its counterfeits and processed products. Furthermore, by in-putting the correlation coefficients of multiple references as the spectral feature data of samples into BP-ANN, a BP-ANN model of qualitative identification was established, of which the accuracy rate was increased to 95%. The MRCC method can be used as a NIR-based method in the process of BP-ANN modeling.

  8. Oral fluid-based biosensors: A novel method for rapid and noninvasive diagnosis

    Directory of Open Access Journals (Sweden)

    K Roja Lakshmi

    2017-01-01

    Full Text Available In the recent times, chair-side/bed-side monitoring tests have gained importance over the routine laboratory tests as they are easier and faster to perform without requiring skilled personnel. Biosensors refer to such type of point-of-care devices that are developed to help in the early diagnosis, periodic monitoring, and treatment of disease. These devices utilize biological reactions for detecting and measuring a particular substance (analyte of interest. Till date, blood has been the gold standard diagnostic fluid for various diseases. However, oral fluids such as saliva and gingival crevicular fluid offer advantages such as noninvasive collection of sample, smaller sample aliquots, easy storage and transportation, repeated sampling for monitoring over time, and greater sensitivity, making them an alternative clinical tool over serum and tissues for many biomedical diagnostic assays. This review highlights the use of oral fluid-based biosensors for diagnosis of caries, periodontitis, oral cancer, and various systemic diseases.

  9. Testing survey-based methods for rapid monitoring of child mortality, with implications for summary birth history data.

    Science.gov (United States)

    Brady, Eoghan; Hill, Kenneth

    2017-01-01

    Under-five mortality estimates are increasingly used in low and middle income countries to target interventions and measure performance against global development goals. Two new methods to rapidly estimate under-5 mortality based on Summary Birth Histories (SBH) were described in a previous paper and tested with data available. This analysis tests the methods using data appropriate to each method from 5 countries that lack vital registration systems. SBH data are collected across many countries through censuses and surveys, and indirect methods often rely upon their quality to estimate mortality rates. The Birth History Imputation method imputes data from a recent Full Birth History (FBH) onto the birth, death and age distribution of the SBH to produce estimates based on the resulting distribution of child mortality. DHS FBHs and MICS SBHs are used for all five countries. In the implementation, 43 of 70 estimates are within 20% of validation estimates (61%). Mean Absolute Relative Error is 17.7.%. 1 of 7 countries produces acceptable estimates. The Cohort Change method considers the differences in births and deaths between repeated Summary Birth Histories at 1 or 2-year intervals to estimate the mortality rate in that period. SBHs are taken from Brazil's PNAD Surveys 2004-2011 and validated against IGME estimates. 2 of 10 estimates are within 10% of validation estimates. Mean absolute relative error is greater than 100%. Appropriate testing of these new methods demonstrates that they do not produce sufficiently good estimates based on the data available. We conclude this is due to the poor quality of most SBH data included in the study. This has wider implications for the next round of censuses and future household surveys across many low- and middle- income countries.

  10. Rapid Classification of Hairtail Fish and Pork Freshness Using an Electronic Nose Based on the PCA Method

    Directory of Open Access Journals (Sweden)

    Yong-Ming Zhang

    2011-12-01

    Full Text Available We report a method for building a simple and reproducible electronic nose based on commercially available metal oxide sensors (MOS to monitor the freshness of hairtail fish and pork stored at 15, 10, and 5 °C. After assembly in the laboratory, the proposed product was tested by a manufacturer. Sample delivery was based on the dynamic headspace method, and two features were extracted from the transient response of each sensor using an unsupervised principal component analysis (PCA method. The compensation method and pattern recognition based on PCA are discussed in the current paper. PCA compensation can be used for all storage temperatures, however, pattern recognition differs according to storage conditions. Total volatile basic nitrogen (TVBN and aerobic bacterial counts of the samples were measured simultaneously with the standard indicators of hairtail fish and pork freshness. The PCA models based on TVBN and aerobic bacterial counts were used to classify hairtail fish samples as “fresh” (TVBN ≤ 25 g and microbial counts ≤ 106 cfu/g or “spoiled” (TVBN ≥ 25 g and microbial counts ≥ 106 cfu/g and pork samples also as “fresh” (TVBN ≤ 15 g and microbial counts ≤ 106 cfu/g or “spoiled” (TVBN ≥ 15 g and microbial counts ≥ 106 cfu/g. Good correlation coefficients between the responses of the electronic nose and the TVBN and aerobic bacterial counts of the samples were obtained. For hairtail fish, correlation coefficients were 0.97 and 0.91, and for pork, correlation coefficients were 0.81 and 0.88, respectively. Through laboratory simulation and field application, we were able to determine that the electronic nose could help ensure the shelf life of hairtail fish and pork, especially when an instrument is needed to take measurements rapidly. The results also showed that the electronic nose could analyze the process and level of spoilage for hairtail fish and pork.

  11. BRaf signaling principles unveiled by large-scale human mutation analysis with a rapid lentivirus-based gene replacement method.

    Science.gov (United States)

    Lim, Chae-Seok; Kang, Xi; Mirabella, Vincent; Zhang, Huaye; Bu, Qian; Araki, Yoichi; Hoang, Elizabeth T; Wang, Shiqiang; Shen, Ying; Choi, Sukwoo; Kaang, Bong-Kiun; Chang, Qiang; Pang, Zhiping P; Huganir, Richard L; Zhu, J Julius

    2017-03-15

    Rapid advances in genetics are linking mutations on genes to diseases at an exponential rate, yet characterizing the gene mutation-cell behavior relationships essential for precision medicine remains a daunting task. More than 350 mutations on small GTPase BRaf are associated with various tumors, and ∼40 mutations are associated with the neurodevelopmental disorder cardio-facio-cutaneous syndrome (CFC). We developed a fast cost-effective lentivirus-based rapid gene replacement method to interrogate the physiopathology of BRaf and ∼50 disease-linked BRaf mutants, including all CFC-linked mutants. Analysis of simultaneous multiple patch-clamp recordings from 6068 pairs of rat neurons with validation in additional mouse and human neurons and multiple learning tests from 1486 rats identified BRaf as the key missing signaling effector in the common synaptic NMDA-R-CaMKII-SynGap-Ras-BRaf-MEK-ERK transduction cascade. Moreover, the analysis creates the original big data unveiling three general features of BRaf signaling. This study establishes the first efficient procedure that permits large-scale functional analysis of human disease-linked mutations essential for precision medicine. © 2017 Lim et al.; Published by Cold Spring Harbor Laboratory Press.

  12. A Rapid Transfer Alignment Method for SINS Based on the Added Backward-Forward SINS Resolution and Data Fusion

    Directory of Open Access Journals (Sweden)

    Xixiang Liu

    2013-01-01

    Full Text Available Two viewpoints are given: (1 initial alignment of strapdown inertial navigation system (SINS can be fulfilled with a set of inertial sensor data; (2 estimation time for sensor errors can be shortened by repeated data fusion on the added backward-forward SINS resolution results and the external reference data. Based on the above viewpoints, aiming to estimate gyro bias in a shortened time, a rapid transfer alignment method, without any changes for Kalman filter, is introduced. In this method, inertial sensor data and reference data in one reference data update cycle are stored, and one backward and one forward SINS resolutions are executed. Meanwhile, data fusion is executed when the corresponding resolution ends. With the added backward-forward SINS resolution, in the above mentioned update cycle, the estimating operations for gyro bias are added twice, and the estimation time for it is shortened. In the ship swinging condition, with the “velocity plus yaw” matching, the effectiveness of this method is proved by the simulation.

  13. A simple PCR-based method for the rapid genotyping of inherited fifth complement component (C5)-deficient mice.

    Science.gov (United States)

    Wang, Qingkai; Wang, Na; Zhang, Xin; Hu, Weiguo

    2015-01-01

    The fifth component of complement (C5) is considered to be the center of complement activation and function. However, there are no genetically engineered knockout mice for this gene, and the only commercially available inherited C5-deficient mice, in which a "TA" nucleotide deletion in the coding frame was previously identified, are in theC57BL/10Sn genetic background rather than the commonly used backgrounds C57BL/6 and BALB/c. Therefore, these mice must be backcrossed into the desired genetic background. Here, we developed an ARMS (amplification refractory mutation system) PCR method using a specific primer pair that was able to discriminate between the genotypes when the resulting product was analyzed by agarose gel electrophoresis. These results were supported by quantitative RT-PCR and semi-quantitative PCR and were consistent with the results from sequencing each backcrossed generation. Using ARMS-PCR method, we generated C5-deficient mice in the C57BL/6 background over 9 backcrossed generations and further verified the phenotype using complement-mediated hemolytic assays. In this study, we describe a simple, rapid and reliable PCR-based method for genotyping inherited C5-deficient mice that may be used to backcross C57BL/10Sn mice into other genetic backgrounds.

  14. Comparison of immunomagnetic separation/adenosine triphosphate rapid method to traditional culture-based method for E. coli and enterococci enumeration in wastewater

    Science.gov (United States)

    Bushon, R.N.; Likirdopulos, C.A.; Brady, A.M.G.

    2009-01-01

    Untreated wastewater samples from California, North Carolina, and Ohio were analyzed by the immunomagnetic separation/adenosine triphosphate (IMS/ATP) method and the traditional culture-based method for E. coli and enterococci concentrations. The IMS/ATP method concentrates target bacteria by immunomagnetic separation and then quantifies captured bacteria by measuring bioluminescence induced by release of ATP from the bacterial cells. Results from this method are available within 1 h from the start of sample processing. Significant linear correlations were found between the IMS/ATP results and results from traditional culture-based methods for E. coli and enterococci enumeration for one location in California, two locations in North Carolina, and one location in Ohio (r??values ranged from 0.87 to 0.97). No significant linear relation was found for a second location in California that treats a complex mixture of residential and industrial wastewater. With the exception of one location, IMS/ATP showed promise as a rapid method for the quantification of faecal-indicator organisms in wastewater.

  15. A rapid and reliable method for discriminating rice products from different regions using MCX-based solid-phase extraction and DI-MS/MS-based metabolomics approach.

    Science.gov (United States)

    Lim, Dong Kyu; Mo, Changyeun; Long, Nguyen Phuoc; Lim, Jongguk; Kwon, Sung Won

    2017-09-01

    The expansion of the global rice marketplace ultimately raises concerns about authenticity control. Several analytical methods for differentiating the geographical origin of rice have been developed, yet a high-throughput method is still in demand. In this study, we developed a rapid approach using direct infusion-mass spectrometry (DI-MS) to distinguish rice products from different countries. Specifically, the elimination of the matrix effect by a polytetrafluoroethylene (PTFE) filter, a mixed-mode cation exchange (MCX) solid-phase extraction (SPE) with 20% methanol, and an MCX SPE with 100% methanol were measured. Afterward, partial least squares discriminant analysis and random forests were applied to seek the optimal discrimination method. The results revealed that the combination of MCX SPE with 100% methanol and DI-MS in positive ion mode (accuracy=1.000, R2=0.916, Q2=0.720, B/W-based p-value=0.015) or the combination of MCX SPE with 20% methanol and targeted DI-MS/MS in positive ion mode (accuracy=1.000, R2=0.931, Q2=0.849, B/W-based p-value=0.002) showed the excellent discriminatory ability. Furthermore, differentially expressed metabolites including sodiated lysophosphatidylcholine, lysophosphatidylcholine, lysophosphatidylethanolamines and lysophosphatidylglycerol classes were found. In conclusion, our study provides a rapid and reliable platform for geographical discrimination of white rice and will contribute to the authenticity control of rice products. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Rapid methods for detection of bacteria

    DEFF Research Database (Denmark)

    Corfitzen, Charlotte B.; Andersen, B.Ø.; Miller, M.

    2006-01-01

    Traditional methods for detection of bacteria in drinking water e.g. Heterotrophic Plate Counts (HPC) or Most Probable Number (MNP) take 48-72 hours to give the result. New rapid methods for detection of bacteria are needed to protect the consumers against contaminations. Two rapid methods...

  17. Innovative rapid construction/reconstruction methods.

    Science.gov (United States)

    2005-07-01

    Innovative construction and reconstruction methods provide the opportunity to significantly reduce the time of roadway projects while maintaining the necessary quality of workmanship. The need for these rapid methods stems from the increase in ...

  18. Genomewide rapid association using mixed model and regression: a fast and simple method for genomewide pedigree-based quantitative trait loci association analysis.

    Science.gov (United States)

    Aulchenko, Yurii S; de Koning, Dirk-Jan; Haley, Chris

    2007-09-01

    For pedigree-based quantitative trait loci (QTL) association analysis, a range of methods utilizing within-family variation such as transmission-disequilibrium test (TDT)-based methods have been developed. In scenarios where stratification is not a concern, methods exploiting between-family variation in addition to within-family variation, such as the measured genotype (MG) approach, have greater power. Application of MG methods can be computationally demanding (especially for large pedigrees), making genomewide scans practically infeasible. Here we suggest a novel approach for genomewide pedigree-based quantitative trait loci (QTL) association analysis: genomewide rapid association using mixed model and regression (GRAMMAR). The method first obtains residuals adjusted for family effects and subsequently analyzes the association between these residuals and genetic polymorphisms using rapid least-squares methods. At the final step, the selected polymorphisms may be followed up with the full measured genotype (MG) analysis. In a simulation study, we compared type 1 error, power, and operational characteristics of the proposed method with those of MG and TDT-based approaches. For moderately heritable (30%) traits in human pedigrees the power of the GRAMMAR and the MG approaches is similar and is much higher than that of TDT-based approaches. When using tabulated thresholds, the proposed method is less powerful than MG for very high heritabilities and pedigrees including large sibships like those observed in livestock pedigrees. However, there is little or no difference in empirical power of MG and the proposed method. In any scenario, GRAMMAR is much faster than MG and enables rapid analysis of hundreds of thousands of markers.

  19. Bioluminescence-based identification of nisin producers - a rapid and simple screening method for nisinogenic bacteria in food samples.

    Science.gov (United States)

    Virolainen, Nina; Guglielmetti, Simone; Arioli, Stefania; Karp, Matti

    2012-08-17

    We present a simple and rapid method for screening nisin producers that directly identifies nisinogenic bacteria by induction of bioluminescence within the Lactococcus lactis NZ9800lux biosensor strain (Immonen and Karp, 2007, Biosensors and Bioelectronics 22, 1982-7). An overlay of putative nisinogenic colonies with the biosensor strain gives identification results within 1h. Functionality and specificity of the method were verified by screening nisin producers among 144 raw milk colonies and a panel of 91 lactococcal strains. Studies performed on strains and colonies that did not induce bioluminescence but inhibited growth of the biosensor demonstrated that only nisinogenic bacteria can cause induction. Bacteria known to produce bacteriocins other than nisin failed to induce bioluminescence, further verifying the specificity of the assay. We discovered a non-inducing but inhibitory lactococcal strain harboring a modified nisin Z gene, and demonstrated that the source of the inhibitory action is not a non-inducing variant of nisin, but a bacteriocin of lower molecular weight. The concentration of nisin producers in a raw milk sample was 1.3 × 10(2)CFU/ml. We identified from raw milk a total of seven nisin Z producing L. lactis subsp. lactis colonies, which were shown by genetic fingerprinting to belong to three different groups. Among the panel of 91 lactococci, four strains were nisin A producers, and one strain harbored the modified nisin Z gene. The method presented here is robust, cost-effective and simple to perform, and avoids the pitfalls of traditional screening methods by directly specifying the identity of the inhibitory substance. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. Rapid and direct spectrophotometric method for kinetics studies and routine assay of peroxidase based on aniline diazo substrates.

    Science.gov (United States)

    Mirazizi, Fatemeh; Bahrami, Azita; Haghbeen, Kamahldin; Shahbani Zahiri, Hossein; Bakavoli, Mehdi; Legge, Raymond L

    2016-12-01

    Peroxidases are ubiquitous enzymes that play an important role in living organisms. Current spectrophotometrically based peroxidase assay methods are based on the production of chromophoric substances at the end of the enzymatic reaction. The ambiguity regarding the formation and identity of the final chromophoric product and its possible reactions with other molecules have raised concerns about the accuracy of these methods. This can be of serious concern in inhibition studies. A novel spectrophotometric assay for peroxidase, based on direct measurement of a soluble aniline diazo substrate, is introduced. In addition to the routine assays, this method can be used in comprehensive kinetics studies. 4-[(4-Sulfophenyl)azo]aniline (λmax = 390 nm, ɛ = 32 880 M(-1) cm(-1) at pH 4.5 to 9) was introduced for routine assay of peroxidase. This compound is commercially available and is indexed as a food dye. Using this method, a detection limit of 0.05 nmol mL(-1) was achieved for peroxidase.

  1. FREQ-Seq: a rapid, cost-effective, sequencing-based method to determine allele frequencies directly from mixed populations.

    Directory of Open Access Journals (Sweden)

    Lon M Chubiz

    Full Text Available Understanding evolutionary dynamics within microbial populations requires the ability to accurately follow allele frequencies through time. Here we present a rapid, cost-effective method (FREQ-Seq that leverages Illumina next-generation sequencing for localized, quantitative allele frequency detection. Analogous to RNA-Seq, FREQ-Seq relies upon counts from the >10(5 reads generated per locus per time-point to determine allele frequencies. Loci of interest are directly amplified from a mixed population via two rounds of PCR using inexpensive, user-designed oligonucleotides and a bar-coded bridging primer system that can be regenerated in-house. The resulting bar-coded PCR products contain the adapters needed for Illumina sequencing, eliminating further library preparation. We demonstrate the utility of FREQ-Seq by determining the order and dynamics of beneficial alleles that arose as a microbial population, founded with an engineered strain of Methylobacterium, evolved to grow on methanol. Quantifying allele frequencies with minimal bias down to 1% abundance allowed effective analysis of SNPs, small in-dels and insertions of transposable elements. Our data reveal large-scale clonal interference during the early stages of adaptation and illustrate the utility of FREQ-Seq as a cost-effective tool for tracking allele frequencies in populations.

  2. A novel high-throughput multi-parameter flow cytometry based method for monitoring and rapid characterization of microbiome dynamics in anaerobic systems.

    Science.gov (United States)

    Dhoble, Abhishek S; Bekal, Sadia; Dolatowski, William; Yanz, Connor; Lambert, Kris N; Bhalerao, Kaustubh D

    2016-11-01

    A novel multidimensional flow cytometry based method has been demonstrated to monitor and rapidly characterize the dynamics of the complex anaerobic microbiome associated with perturbations in external environmental factors. While community fingerprinting provides an estimate of the meta genomic structure, flow cytometry provides a fingerprint of the community morphology including its autofluorescence spectrum in a high-throughput manner. Using anaerobic microbial consortia perturbed with the controlled addition of various carbon sources, it is possible to quantitatively discriminate between divergent microbiome analogous to community fingerprinting techniques using automated ribosomal intergenic spacer analysis (ARISA). The utility of flow cytometry based method has also been demonstrated in a fully functional industry scale anaerobic digester to distinguish between microbiome composition caused by varying hydraulic retention time (HRT). This approach exploits the rich multidimensional information from flow cytometry for rapid characterization of the dynamics of microbial communities. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. A new method for rapid Canine retraction

    Directory of Open Access Journals (Sweden)

    "Khavari A

    2001-06-01

    Full Text Available Distraction osteogenesis method (Do in bone lengthening and rapid midpalatal expansion have shown the great ability of osteognic tissues for rapid bone formation under distraction force and special protocol with optimum rate of one millimeter per day. Periodontal membrane of teeth (PDM is the extension of periostium in the alveolar socked. Orthodontic force distracts PDM fibers in the tension side and then bone formation will begin.Objects: Rapid retraction of canine tooth into extraction space of first premolar by DO protocol in order to show the ability of the PDM in rapid bone formation. The other objective was reducing total orthodontic treatment time of extraction cases.Patients and Methods: Tweleve maxillary canines in six patients were retracted rapidly in three weeks by a custom-made tooth-born appliance. Radiographic records were taken to evaluate the effects of heavy applied force on canine and anchorage teeth.Results: Average retraction was 7.05 mm in three weeks (2.35 mm/week. Canines rotated distal- in by mean 3.5 degrees.Anchorage loss was from 0 to 0.8 mm with average of 0.3 mm.Root resorption of canines was negligible, and was not significant clinically. Periodontium was normal after rapid retraction. No hazard for pulp vitality was observed.Discussion: PDM responded well to heavy distraction force by Do protocol. Rapid canine retraction seems to be a safe method and can considerabely reduce orthodontic time.

  4. Controlled multicenter evaluation of a bacteriophage-based method for rapid detection of Staphylococcus aureus in positive blood cultures.

    Science.gov (United States)

    Bhowmick, T; Mirrett, S; Reller, L B; Price, C; Qi, C; Weinstein, M P; Kirn, T J

    2013-04-01

    Staphylococci are a frequent cause of bloodstream infections (BSIs). Appropriate antibiotic treatment for BSIs may be delayed because conventional laboratory testing methods take 48 to 72 h to identify and characterize isolates from positive blood cultures. We evaluated a novel assay based on bacteriophage amplification that identifies Staphylococcus aureus and differentiates between methicillin-susceptible and methicillin-resistant S. aureus (MSSA and MRSA, respectively) in samples taken directly from signal-positive Bactec blood culture bottles within 24 h of positive signal, with results available within 5 h. The performance of the MicroPhage KeyPath MRSA/MSSA blood culture test was compared to conventional identification and susceptibility testing methods. At four sites, we collectively tested a total of 1,165 specimens, of which 1,116 were included in our analysis. Compared to standard methods, the KeyPath MRSA/MSSA blood culture test demonstrated a sensitivity, specificity, positive predictive value, and negative predictive value of 91.8%, 98.3%, 96.3%, and 96.1%, respectively, for correctly identifying S. aureus. Of those correctly identified as S. aureus (n = 334), 99.1% were correctly categorized as either MSSA or MRSA. Analysis of a subset of the data revealed that the KeyPath MRSA/MSSA blood culture test delivered results a median of 30 h sooner than conventional methods (a median of 46.9 h versus a median of 16.9 h). Although the sensitivity of the test in detecting S. aureus-positive samples is not high, its accuracy in determining methicillin resistance and susceptibility among positives is very high. These characteristics may enable earlier implementation of appropriate antibiotic treatment for many S. aureus BSI patients.

  5. A scoping review of rapid review methods.

    Science.gov (United States)

    Tricco, Andrea C; Antony, Jesmin; Zarin, Wasifa; Strifler, Lisa; Ghassemi, Marco; Ivory, John; Perrier, Laure; Hutton, Brian; Moher, David; Straus, Sharon E

    2015-09-16

    Rapid reviews are a form of knowledge synthesis in which components of the systematic review process are simplified or omitted to produce information in a timely manner. Although numerous centers are conducting rapid reviews internationally, few studies have examined the methodological characteristics of rapid reviews. We aimed to examine articles, books, and reports that evaluated, compared, used or described rapid reviews or methods through a scoping review. MEDLINE, EMBASE, the Cochrane Library, internet websites of rapid review producers, and reference lists were searched to identify articles for inclusion. Two reviewers independently screened literature search results and abstracted data from included studies. Descriptive analysis was conducted. We included 100 articles plus one companion report that were published between 1997 and 2013. The studies were categorized as 84 application papers, seven development papers, six impact papers, and four comparison papers (one was included in two categories). The rapid reviews were conducted between 1 and 12 months, predominantly in Europe (58 %) and North America (20 %). The included studies failed to report 6 % to 73 % of the specific systematic review steps examined. Fifty unique rapid review methods were identified; 16 methods occurred more than once. Streamlined methods that were used in the 82 rapid reviews included limiting the literature search to published literature (24 %) or one database (2 %), limiting inclusion criteria by date (68 %) or language (49 %), having one person screen and another verify or screen excluded studies (6 %), having one person abstract data and another verify (23 %), not conducting risk of bias/quality appraisal (7 %) or having only one reviewer conduct the quality appraisal (7 %), and presenting results as a narrative summary (78 %). Four case studies were identified that compared the results of rapid reviews to systematic reviews. Three studies found that the conclusions between

  6. A rapid and efficient polyethylenimine-based transfection method to prepare lentiviral or retroviral vectors: useful for making iPS cells and transduction of primary cells.

    Science.gov (United States)

    Yang, Shaozhe; Shi, Haijun; Chu, Xinran; Zhou, Xiaoling; Sun, Pingnan

    2016-09-01

    To improve the efficiency, reproducibility and consistency of the PEI-based transfection method that is often used in preparation of recombinant lentiviral or retroviral vectors. The contributions to transfection efficiency of multi-factors including concentration of PEI or DNA, dilution buffer for PEI/DNA, manner to prepare PEI/DNA complexes, influence of serum, incubation time for PEI/DNA complexes, and transfection time were studied. Gentle mixing during the preparation of PEI/DNA transfection complexes is critical for a high transfection efficiency. PEI could be stored at room temperature or 4 °C, and most importantly, multigelation should be avoided. The transfection efficiency of the PEI-based new method in different types of cells, such as 293T, Cos-7, HeLa, HepG2, Hep3B, Huh7 and L02, was also higher than that of the previous method. After optimization, the titer of our lentiviral system or retroviral system produced by PEI-based new method was about 10- or 3-times greater than that produced by PEI-based previous method, respectively. We provide a rapid and efficient PEI-based method for preparation of recombinant lentiviral or retroviral vectors which is useful for making iPS cells as well as transduction of primary cell cultures.

  7. Grid-based mapping: A method for rapidly determining the spatial distributions of small features over very large areas

    Science.gov (United States)

    Ramsdale, Jason D.; Balme, Matthew R.; Conway, Susan J.; Gallagher, Colman; van Gasselt, Stephan A.; Hauber, Ernst; Orgel, Csilla; Séjourné, Antoine; Skinner, James A.; Costard, Francois; Johnsson, Andreas; Losiak, Anna; Reiss, Dennis; Swirad, Zuzanna M.; Kereszturi, Akos; Smith, Isaac B.; Platz, Thomas

    2017-06-01

    The increased volume, spatial resolution, and areal coverage of high-resolution images of Mars over the past 15 years have led to an increased quantity and variety of small-scale landform identifications. Though many such landforms are too small to represent individually on regional-scale maps, determining their presence or absence across large areas helps form the observational basis for developing hypotheses on the geological nature and environmental history of a study area. The combination of improved spatial resolution and near-continuous coverage significantly increases the time required to analyse the data. This becomes problematic when attempting regional or global-scale studies of metre and decametre-scale landforms. Here, we describe an approach for mapping small features (from decimetre to kilometre scale) across large areas, formulated for a project to study the northern plains of Mars, and provide context on how this method was developed and how it can be implemented. Rather than ;mapping; with points and polygons, grid-based mapping uses a ;tick box; approach to efficiently record the locations of specific landforms (we use an example suite of glacial landforms; including viscous flow features, the latitude dependant mantle and polygonised ground). A grid of squares (e.g. 20 km by 20 km) is created over the mapping area. Then the basemap data are systematically examined, grid-square by grid-square at full resolution, in order to identify the landforms while recording the presence or absence of selected landforms in each grid-square to determine spatial distributions. The result is a series of grids recording the distribution of all the mapped landforms across the study area. In some ways, these are equivalent to raster images, as they show a continuous distribution-field of the various landforms across a defined (rectangular, in most cases) area. When overlain on context maps, these form a coarse, digital landform map. We find that grid-based mapping

  8. Rapid and sensitive lateral flow immunoassay method for determining alpha fetoprotein in serum using europium (III) chelate microparticles-based lateral flow test strips

    Energy Technology Data Exchange (ETDEWEB)

    Liang, Rong-Liang; Xu, Xu-Ping; Liu, Tian-Cai; Zhou, Jian-Wei; Wang, Xian-Guo; Ren, Zhi-Qi [Institute of Antibody Engineering, School of Biotechnology, Southern Medical University, Guangzhou 510515, Guangdong (China); Hao, Fen [DaAn Gene Co. Ltd. of Sun Yat-sen University, 19 Xiangshan Road, Guangzhou 510515 (China); Wu, Ying-Song, E-mail: wg@smu.edu.cn [Institute of Antibody Engineering, School of Biotechnology, Southern Medical University, Guangzhou 510515, Guangdong (China)

    2015-09-03

    Alpha-fetoprotein (AFP), a primary marker for many diseases including various cancers, is important in clinical tumor diagnosis and antenatal screening. Most immunoassays provide high sensitivity and accuracy for determining AFP, but they are expensive, often complex, time-consuming procedures. A simple and rapid point-of-care system that integrates Eu (III) chelate microparticles with lateral flow immunoassay (LFIA) has been developed to determine AFP in serum with an assay time of 15 min. The approach is based on a sandwich immunoassay performed on lateral flow test strips. A fluorescence strip reader was used to measure the fluorescence peak heights of the test line (H{sub T}) and the control line (H{sub C}); the H{sub T}/H{sub C} ratio was used for quantitation. The Eu (III) chelate microparticles-based LFIA assay exhibited a wide linear range (1.0–1000 IU mL{sup −1}) for AFP with a low limit of detection (0.1 IU mL{sup −1}) based on 5ul of serum. Satisfactory specificity and accuracy were demonstrated and the intra- and inter-assay coefficients of variation (CV) for AFP were both <10%. Furthermore, in the analysis of human serum samples, excellent correlation (n = 284, r = 0.9860, p < 0.0001) was obtained between the proposed method and a commercially available CLIA kit. Results indicated that the Eu (III) chelate microparticles-based LFIA system provided a rapid, sensitive and reliable method for determining AFP in serum, indicating that it would be suitable for development in point-of-care testing. - Highlights: • Europium (III) chelate microparticles was used as a label for LIFA. • Quantitative detection by using H{sub T}/H{sub C} ratio was achieved. • LIFA for simple and rapid AFP detection in human serum. • The sensitivity and linearity was more excellent compared with QD-based ICTS. • This method could be developed for rapid point-of-care screening.

  9. Rapid and sensitive lateral flow immunoassay method for determining alpha fetoprotein in serum using europium (III) chelate microparticles-based lateral flow test strips.

    Science.gov (United States)

    Liang, Rong-Liang; Xu, Xu-Ping; Liu, Tian-Cai; Zhou, Jian-Wei; Wang, Xian-Guo; Ren, Zhi-Qi; Hao, Fen; Wu, Ying-Song

    2015-09-03

    Alpha-fetoprotein (AFP), a primary marker for many diseases including various cancers, is important in clinical tumor diagnosis and antenatal screening. Most immunoassays provide high sensitivity and accuracy for determining AFP, but they are expensive, often complex, time-consuming procedures. A simple and rapid point-of-care system that integrates Eu (III) chelate microparticles with lateral flow immunoassay (LFIA) has been developed to determine AFP in serum with an assay time of 15 min. The approach is based on a sandwich immunoassay performed on lateral flow test strips. A fluorescence strip reader was used to measure the fluorescence peak heights of the test line (HT) and the control line (HC); the HT/HC ratio was used for quantitation. The Eu (III) chelate microparticles-based LFIA assay exhibited a wide linear range (1.0-1000 IU mL(-1)) for AFP with a low limit of detection (0.1 IU mL(-1)) based on 5ul of serum. Satisfactory specificity and accuracy were demonstrated and the intra- and inter-assay coefficients of variation (CV) for AFP were both <10%. Furthermore, in the analysis of human serum samples, excellent correlation (n = 284, r = 0.9860, p < 0.0001) was obtained between the proposed method and a commercially available CLIA kit. Results indicated that the Eu (III) chelate microparticles-based LFIA system provided a rapid, sensitive and reliable method for determining AFP in serum, indicating that it would be suitable for development in point-of-care testing. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. The Verification of the Usefulness of Electronic Nose Based on Ultra-Fast Gas Chromatography and Four Different Chemometric Methods for Rapid Analysis of Spirit Beverages

    Directory of Open Access Journals (Sweden)

    Paulina Wiśniewska

    2016-01-01

    Full Text Available Spirit beverages are a diverse group of foodstuffs. They are very often counterfeited which cause the appearance of low quality products or wrongly labelled products on the market. It is important to find a proper quality control and botanical origin method enabling the same time preliminary check of the composition of investigated samples, which was the main goal of this work. For this purpose, the usefulness of electronic nose based on ultra-fast gas chromatography (fast GC e-nose was verified. A set of 24 samples of raw spirits, 33 samples of vodkas, and 8 samples of whisky were analysed by fast GC e-nose. Four data analysis methods were used. The PCA was applied for the visualization of dataset, observation of the variation inside groups of samples, and selection of variables for the other three statistical methods. The SQC method was utilized to compare the quality of the samples. Both the DFA and SIMCA data analysis methods were used for discrimination of vodka, whisky, and spirits samples. The fast GC e-nose combined with four statistical methods can be used for rapid discrimination of raw spirits, vodkas, and whisky and in the same for preliminary determination of the composition of investigated samples.

  11. Rapid determination of capsaicinoids by colorimetric method

    OpenAIRE

    Ryu, Wang-Kyun; Kim, Hee-Woong; Kim, Geun-Dong; Rhee, Hae-Ik

    2016-01-01

    Capsaicinoids, the pungent component of chili peppers, are generally analyzed by precise analytical techniques, such as gas chromatography and high-performance liquid chromatography (HPLC), but these are not practical for the mass analyses of samples. To analyze mass samples rapidly, a colorimetric method was suggested. In this work, pigments and capsaicinoids were efficiently separated from chili pepper extract by sequential solid–liquid extraction and liquid–liquid extraction in test tubes ...

  12. A rapid liquid chromatography tandem mass spectrometry-based method for measuring propranolol on dried blood spots.

    Science.gov (United States)

    Della Bona, Maria Luisa; Malvagia, Sabrina; Villanelli, Fabio; Giocaliere, Elisa; Ombrone, Daniela; Funghini, Silvia; Filippi, Luca; Cavallaro, Giacomo; Bagnoli, Paola; Guerrini, Renzo; la Marca, Giancarlo

    2013-05-05

    Propranolol, a non-selective beta blocker drug, is used in young infants and newborns for treating several heart diseases; its pharmacokinetics has been extensively evaluated in adult patients using extrapolation to treat pediatric population. The purpose of the present study was to develop and validate a method to measure propranolol levels in dried blood spots. The analysis was performed by using liquid chromatography/tandem mass spectrometry operating in multiple reaction monitoring mode. The calibration curve in matrix was linear in the concentration range of 2.5-200 μg/L with correlation coefficient r=0.9996. Intra-day and inter-day precisions and biases were less than 8.0% (n=10) and 11.5% (n=10) respectively. The recoveries ranged from 94 to 100% and the matrix effect did not result in a severe signal suppression. Propranolol on dried blood spot showed a good stability at three different temperatures for one month. This paper describes a micromethod for measuring propranolol levels on dried blood spot, which determines a great advantage in neonates or young infants during pharmacokinetic studies because of less invasive sampling and small blood volume required. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. Rapid and Accurate Determination of Lipopolysaccharide O-Antigen Types in Klebsiella pneumoniae with a Novel PCR-Based O-Genotyping Method

    Science.gov (United States)

    Shih, Yun-Jui; Cheong, Cheng-Man; Yi, Wen-Ching

    2015-01-01

    Klebsiella pneumoniae, a Gram-negative bacillus that causes life-threatening infections in both hospitalized patients and ambulatory persons, can be classified into nine lipopolysaccharide (LPS) O-antigen serotypes. The O-antigen type has important clinical and epidemiological significance. However, K. pneumoniae O serotyping is cumbersome, and the reagents are not commercially available. To overcome the limitations of conventional serotyping methods, we aimed to create a rapid and accurate PCR method for K. pneumoniae O genotyping. We sequenced the genetic determinants of LPS O antigen from serotypes O1, O2a, O2ac, O3, O4, O5, O8, O9, and O12. We established a two-step genotyping scheme, based on the two genomic regions associated with O-antigen biosynthesis. The first set of PCR primers, which detects alleles at the wzm-wzt loci of the wb gene cluster, distinguishes between O1/O2, O3, O4, O5, O8, O9, and O12. The second set of PCR primers, which detects alleles at the wbbY region, further differentiates between O1, O2a, and O2ac. We verified the specificity of O genotyping against the O-serotype reference strains. We then tested the sensitivity and specificity of O genotyping in K. pneumoniae, using the 56 K-serotype reference strains with known O serotypes determined by an inhibition enzyme-linked immunosorbent assay (iELISA). There is a very good correlation between the O genotypes and classical O serotypes. Three discrepancies were observed and resolved by nucleotide sequencing—all in favor of O genotyping. The PCR-based O genotyping, which can be easily performed in clinical and research microbiology laboratories, is a rapid and accurate method for determining the LPS O-antigen types of K. pneumoniae isolates. PMID:26719438

  14. Motion Analysis Based on Invertible Rapid Transform

    Directory of Open Access Journals (Sweden)

    J. Turan

    1999-06-01

    Full Text Available This paper presents the results of a study on the use of invertible rapid transform (IRT for the motion estimation in a sequence of images. Motion estimation algorithms based on the analysis of the matrix of states (produced in the IRT calculation are described. The new method was used experimentally to estimate crowd and traffic motion from the image data sequences captured at railway stations and at high ways in large cities. The motion vectors may be used to devise a polar plot (showing velocity magnitude and direction for moving objects where the dominant motion tendency can be seen. The experimental results of comparison of the new motion estimation methods with other well known block matching methods (full search, 2D-log, method based on conventional (cross correlation (CC function or phase correlation (PC function for application of crowd motion estimation are also presented.

  15. Rapid shotgun proteomic liquid chromatography-electrospray ionization-tandem mass spectrometry-based method for the lupin ( Lupinus albus L.) multi-allergen determination in foods.

    Science.gov (United States)

    Mattarozzi, Monica; Bignardi, Chiara; Elviri, Lisa; Careri, Maria

    2012-06-13

    Allergy to lupin is a growing food safety problem because this legume, increasingly exploited in the food industry, is one of the allergens that, according to law, must be declared on the labels of food products in the European Union. In this context, a rapid targeted proteomic approach based on liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) analysis was proposed and aimed to unequivocal confirmation and reliable determination of the major lupin allergens, i.e., conglutins, in pasta and biscuits. Detected concentrations were around 1 mg of lupin/kg of pasta and biscuits, proving the capabilities of the MS-based method in terms of the sensitive allergen screening method. Good precision was observed in terms of both intra- and interday repeatability, with relative standard deviation (RSD) lower than 23%. Recoveries from 95 ± 10 to 118 ± 12% and from 103 ± 1 to 110 ± 12% ranges were calculated for biscuits and pasta, respectively. Finally, the applicability of the devised method was investigated by analyzing market samples containing lupin and samples that may possibly contain traces of lupin deriving from cross-contamination between products and production lines.

  16. PCR method for the rapid detection and discrimination of Legionella spp. based on the amplification of pcs, pmtA, and 16S rRNA genes.

    Science.gov (United States)

    Janczarek, Monika; Palusińska-Szysz, Marta

    2016-05-01

    Legionella bacteria are organisms of public health interest due to their ability to cause pneumonia (Legionnaires' disease) in susceptible humans and their ubiquitous presence in water supply systems. Rapid diagnosis of Legionnaires' disease allows the use of therapy specific for the disease. L. pneumophila serogroup 1 is the most common cause of infection acquired in community and hospital environments. The non-L. pneumophila infections are likely under-detected because of a lack of effective diagnosis. In this work, simplex and duplex PCR assays with the use of new molecular markers pcs and pmtA involved in phosphatidylcholine synthesis were specified for rapid and cost-efficient identification and distinguishing Legionella species. The sets of primers developed were found to be sensitive and specific for reliable detection of Legionella belonging to the eight most clinically relevant species. Among these, four primer sets I, II, VI, and VII used for duplex-PCRs proved to have the highest identification power and reliability in the detection of the bacteria. Application of this PCR-based method should improve detection of Legionella spp. in both clinical and environmental settings and facilitate molecular typing of these organisms.

  17. Rapid and reliable QuEChERS-based LC-MS/MS method for determination of acrylamide in potato chips and roasted coffee

    Science.gov (United States)

    Stefanović, S.; Đorđevic, V.; Jelušić, V.

    2017-09-01

    The aim of this paper is to verify the performance characteristics and fitness for purpose of rapid and simple QuEChERS-based LC-MS/MS method for determination of acrylamide in potato chips and coffee. LC-MS/MS is by far the most suitable analytical technique for acrylamide measurements given its inherent sensitivity and selectivity, as well as capability of analyzing underivatized molecule. Acrylamide in roasted coffee and potato chips wasextracted with water:acetonitrile mixture using NaCl and MgSO4. Cleanup was carried out with MgSO4 and PSA. Obtained results were satisfactory. Recoveries were in the range of 85-112%, interlaboratory reproducibility (Cv) was 5.8-7.6% and linearity (R2) was in the range of 0.995-0.999. LoQ was 35 μg kg-1 for coffee and 20 μg kg-1 for potato chips. Performance characteristic of the method are compliant with criteria for analytical methods validation. Presented method for quantitative determination of acrylamide in roasted coffee and potato chips is fit for purposes of self-control in food industry as well as regulatory controls carried out by the governmental agencies.

  18. Rapid Column Extraction method for SoilRapid Column Extraction method for Soil

    Energy Technology Data Exchange (ETDEWEB)

    Maxwell, Sherrod, L. III; Culligan, Brian K.

    2005-11-07

    The analysis of actinides in environmental soil and sediment samples is very important for environmental monitoring as well as for emergency preparedness. A new, rapid actinide separation method has been developed and implemented that provides total dissolution of large soil samples, high chemical recoveries and effective removal of matrix interferences. This method uses stacked TEVA Resin{reg_sign}, TRU Resin{reg_sign} and DGA-Resin{reg_sign} cartridges from Eichrom Technologies (Darien, IL, USA) that allows the rapid separation of plutonium (Pu) neptunium (Np), uranium (U), americium (Am), and curium (Cm) using a single multi-stage column combined with alpha spectrometry. The method combines a rapid fusion step for total dissolution to dissolve refractory analytes and matrix removal using cerium fluoride precipitation to remove the difficult soil matrix. By using vacuum box cartridge technology with rapid flow rates, sample preparation time is minimized.

  19. Development of a flow cytometry based method for rapid and sensitive detection of a novel marine fish iridovirus in cell culture.

    Science.gov (United States)

    Qin, Qi Wei; Gin, Karina Yew-Hoong; Lee, Li Yen; Gedaria, Alice Ilaya; Zhang, Sheng

    2005-04-01

    A sensitive and accurate flow cytometry (FCM) based method has been developed to detect and quantitate a novel marine fish iridovirus (Singapore grouper iridovirus, SGIV) after amplification in cell cultures. Confluent grouper cell (GP) monolayers were infected with SGIV. When advanced cytopathic effect (CPE) appeared, the cell cultures were fixed and permeabilized, and then reacted with monoclonal antibodies specific against SGIV, followed by a second antibody conjugated with FITC (anti-mouse IgG-FITC). A Coulter EPICS Elite ESP flow cytometer was used to directly detect and analyze the percentage of virus-infected cells. Three fixation and permeabilization methods were evaluated. The kinetics of the virus infection process was determined. The FCM procedure enables large amounts of cells to be screened rapidly for infectivity, and it can also detect low levels of virus infection. As early as 8 h after inoculation with the virus, 0.34% of infected cells were detected in cell culture. The maximum level of infection was obtained at 72 h. The efficiency and reliability of the FCM procedure were compared with those of the standard methods of immunofluorescence microscopy and PCR.

  20. [A method for rapid extracting three-dimensional root model of vivo tooth from cone beam computed tomography data based on the anatomical characteristics of periodontal ligament].

    Science.gov (United States)

    Zhao, Y J; Wang, S W; Liu, Y; Wang, Y

    2017-02-18

    To explore a new method for rapid extracting and rebuilding three-dimensional (3D) digital root model of vivo tooth from cone beam computed tomography (CBCT) data based on the anatomical characteristics of periodontal ligament, and to evaluate the extraction accuracy of the method. In the study, 15 extracted teeth (11 with single root, 4 with double roots) were collected from oral clinic and 3D digital root models of each tooth were obtained by 3D dental scanner with a high accuracy 0.02 mm in STL format. CBCT data for each patient were acquired before tooth extraction, DICOM data with a voxel size 0.3 mm were input to Mimics 18.0 software. Segmentation, Morphology operations, Boolean operations and Smart expanded function in Mimics software were used to edit teeth, bone and periodontal ligament threshold mask, and root threshold mask were automatically acquired after a series of mask operations. 3D digital root models were extracted in STL format finally. 3D morphology deviation between the extracted root models and corresponding vivo root models were compared in Geomagic Studio 2012 software. The 3D size errors in long axis, bucco-lingual direction and mesio-distal direction were also calculated. The average value of the 3D morphology deviation for 15 roots by calculating Root Mean Square (RMS) value was 0.22 mm, the average size errors in the mesio-distal direction, the bucco-lingual direction and the long axis were 0.46 mm, 0.36 mm and -0.68 mm separately. The average time of this new method for extracting single root was about 2-3 min. It could meet the accuracy requirement of the root 3D reconstruction fororal clinical use. This study established a new method for rapid extracting 3D root model of vivo tooth from CBCT data. It could simplify the traditional manual operation and improve the efficiency and automation of single root extraction. The strategy of this method for complete dentition extraction needs further research.

  1. A rapid and accurate method for determining protein content in dairy products based on asynchronous-injection alternating merging zone flow-injection spectrophotometry.

    Science.gov (United States)

    Liang, Qin-Qin; Li, Yong-Sheng

    2013-12-01

    An accurate and rapid method and a system to determine protein content using asynchronous-injection alternating merging zone flow-injection spectrophotometry based on reaction between coomassie brilliant blue G250 (CBBG) and protein was established. Main merit of our approach is that it can avoid interferences of other nitric-compounds in samples, such as melamine and urea. Optimized conditions are as follows: Concentrations of CBBG, polyvinyl alcohol (PVA), NaCl and HCl are 150 mg/l, 30 mg/l, 0.1 mol/l and 1.0% (v/v), respectively; volumes of the sample and reagent are 150 μl and 30 μl, respectively; length of a reaction coil is 200 cm; total flow rate is 2.65 ml/min. The linear range of the method is 0.5-15 mg/l (BSA), its detection limit is 0.05 mg/l, relative standard deviation is less than 1.87% (n=11), and analytical speed is 60 samples per hour. Copyright © 2013 Elsevier Ltd. All rights reserved.

  2. Development of a high-performance liquid chromatography method based on a core-shell column approach for the rapid determination of multiclass polyphenols in grape pomaces.

    Science.gov (United States)

    Fontana, Ariel R; Antoniolli, Andrea; Bottini, Rubén

    2016-02-01

    A rapid and economically affordable reverse-phase chromatographic approach based on a core-shell column with high-performance liquid chromatography multi-wavelength detector (HPLC-MWD) is proposed for the quantification and quality control of multiclass polyphenols (PPs). The separation of 20 relevant polyphenols from grape pomace extracts (GPEs) was achieved in less than 12 min by using a Kinetex C18 column (3.0 mm × 100 mm, 2.6 μm) with a gradient system of ultrapure water (0.1% formic acid) and acetonitrile, a temperature of 35 °C and a flow rate of 0.8 mL min(-1). The maximum backpressure reached was 327 bar, meaning the developed method is adequate for standard HPLC instruments. The applicability of the method was demonstrated by the determination of PPs in GPEs of different red grape varieties. Cabernet Sauvignon GPE showed the highest content of studied PPs (9804.2 μg g(-1)GPE) followed by Bonarda GPE (7302.0 μg g(-1)GPE). Besides the methodological development for a high throughput routine quality control of GPEs, this is the first report of PPs content for Bonarda and Aspirant Bouchet GPE, so the results add knowledge for these grape varieties cultivated in Argentina. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. A new pH indicator dye-based method for rapid and efficient screening of l-asparaginase producing microorganisms.

    Science.gov (United States)

    Mihooliya, Kanti N; Nandal, Jitender; Swami, Laxmi; Verma, Himanshu; Chopra, Lipsy; Sahoo, Debendra K

    2017-12-01

    l-asparaginase is a pharmaceutically and industrially important enzyme as it has potential to treat different cancers and inhibit acrylamide formation in fried and baked food products. In the present study, an attempt was made to screen for new and novel l-asparaginase producers using a widely applied phenol red and bromothymol blue (BTB)1 dye-based plate assay. Screening of four different soil samples for l-asparaginase producers resulted in the isolation of three new potential l-asparaginase producing bacteria. These three strains identified (by 16S rRNA sequencing) as a Pseudomonas resinovorans strain IGS-131, a Bacillus safensis strain IGS-81, and a Glutamicibacter arilaitensis strain ICS-13 with enzyme activities of 10.91 IU/ml, 6.65 IU/ml, and 1.47 IU/ml, respectively. These three strains of bacteria have not been reported as l-asparaginase producers previously. Also, we developed a new pH indicator dye-based plate assay for the screening of l-asparaginase producers after testing eight different pH indicator dyes. This cresol red dye-based method gave a better differentiable zone of hydrolysis and consistent results as compared to previously reported phenol red and BTB-based plate assay. It was also found to be efficient in comparison to all other dyes studied. It produced a bright yellow color at acidic pH (5.5) and turned into a dark red or maroon color when pH was increased (above 7.5). This finding is expected to make screening of all kinds of l-asparaginases more comfortable, rapid, and efficient. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Rapid determination of capsaicinoids by colorimetric method.

    Science.gov (United States)

    Ryu, Wang-Kyun; Kim, Hee-Woong; Kim, Geun-Dong; Rhee, Hae-Ik

    2017-10-01

    Capsaicinoids, the pungent component of chili peppers, are generally analyzed by precise analytical techniques, such as gas chromatography and high-performance liquid chromatography (HPLC), but these are not practical for the mass analyses of samples. To analyze mass samples rapidly, a colorimetric method was suggested. In this work, pigments and capsaicinoids were efficiently separated from chili pepper extract by sequential solid-liquid extraction and liquid-liquid extraction in test tubes followed by a colorimetric analysis on the capsaicinoids by a selective chromogenic reaction with Gibbs reagent (2,6-dichloroquinone-4-chloroimide). In the comparison of the capsaicinoid content by the colorimetric method and HPLC using acetone extracts of fresh pepper and dry red pepper as samples, R2 was 0.9973 and 0.9816, respectively, which shows a high linear correlation. In addition, a minimum of 1 μg/mL capsaicinoids can be detected and it was therefore determined that the method can efficiently analyze a great quantity of samples in a short time. Copyright © 2016. Published by Elsevier B.V.

  5. Rapid determination of capsaicinoids by colorimetric method

    Directory of Open Access Journals (Sweden)

    Wang-Kyun Ryu

    2017-10-01

    Full Text Available Capsaicinoids, the pungent component of chili peppers, are generally analyzed by precise analytical techniques, such as gas chromatography and high-performance liquid chromatography (HPLC, but these are not practical for the mass analyses of samples. To analyze mass samples rapidly, a colorimetric method was suggested. In this work, pigments and capsaicinoids were efficiently separated from chili pepper extract by sequential solid–liquid extraction and liquid–liquid extraction in test tubes followed by a colorimetric analysis on the capsaicinoids by a selective chromogenic reaction with Gibbs reagent (2,6-dichloroquinone-4-chloroimide. In the comparison of the capsaicinoid content by the colorimetric method and HPLC using acetone extracts of fresh pepper and dry red pepper as samples, R2 was 0.9973 and 0.9816, respectively, which shows a high linear correlation. In addition, a minimum of 1 μg/mL capsaicinoids can be detected and it was therefore determined that the method can efficiently analyze a great quantity of samples in a short time.

  6. Methods and compositions for rapid thermal cycling

    Science.gov (United States)

    Beer, Neil Reginald; Benett, William J.; Frank, James M.; Deotte, Joshua R.; Spadaccini, Christopher

    2015-10-27

    The rapid thermal cycling of a material is targeted. A microfluidic heat exchanger with an internal porous medium is coupled to tanks containing cold fluid and hot fluid. Fluid flows alternately from the cold tank and the hot tank into the porous medium, cooling and heating samples contained in the microfluidic heat exchanger's sample wells. A valve may be coupled to the tanks and a pump, and switching the position of the valve may switch the source and direction of fluid flowing through the porous medium. A controller may control the switching of valve positions based on the temperature of the samples and determined temperature thresholds. A sample tray for containing samples to be thermally cycled may be used in conjunction with the thermal cycling system. A surface or internal electrical heater may aid in heating the samples, or may replace the necessity for the hot tank.

  7. Automated Sample Preparation (ASP): Development of a Rapid Method to Sequentially Isolate Nucleic Acids and Protein from Any Sample Type by a Cartridge-Based System

    Science.gov (United States)

    2013-11-27

    by the buffer solution. For instance, the DNAPro appears to perform better when the diluent was Joint Portal Shield Buffer. This relationship did...spores and comparison of DNA yields from spores and spiked environmental samples. Journal of Microbiological Methods, 2009. 76(1): p. 30-37. 3...time PCR. European Journal of Clinical Microbiology & Infectious Diseases, 2008. 27(2): p. 109-114. 4. Boom, R., et al., Rapid and simple method

  8. A new turn-on fluorimetric method for the rapid speciation of Cr(III)/Cr(VI) species in tea samples with rhodamine-based fluorescent reagent

    Science.gov (United States)

    Özyol, Esra; Saçmacı, Şerife; Saçmacı, Mustafa; Ülgen, Ahmet

    2018-02-01

    A new fluorimetric method with rhodamine-based fluorescent agent was developed for the rapid speciation of Cr(III)/Cr(VI) in tea, soil and water samples. The system, which utilizes a fluorescent reagent, was used for the first time after synthesis/characterization of 3‧,6‧-bis(diethylamino)-2-{[(1E)-(2,4-dimethoxyphenyl)methylene] amino}spiro[isoindole-1,9‧-xanthen]-3(2H)-one (BDAS). The reagent responds instantaneously at room temperature in a 1:1 stoichiometric manner to the amount of Cr(III). The selectivity of this system for Cr(III) over other metal ions is remarkably high, and its sensitivity is below 0.01 mg L- 1 in aqueous solutions which enables a simplification without any pretreatment of the real sample. The method has a wide linear range of 0.1-10 mg L- 1 and a detection limit of 0.15 μg L- 1 for Cr(III) while the relative standard deviation was 0.1% for 0.1 mg L- 1 Cr(III) concentration. The results of detection and recovery experiments for Cr(III) in tea, soil and water were satisfactory, indicating that the method has better feasibility and application potential in the routine determination and speciation of Cr(III)/Cr(VI). The results of analysis of the certified reference material (INCT-TL-1 tea sample and CWW-TM-D waste water) are in good agreement with the certified value.

  9. An Object-Based Image Analysis Method for Monitoring Land Conversion by Artificial Sprawl Use of RapidEye and IRS Data

    Directory of Open Access Journals (Sweden)

    Maud Balestrat

    2012-02-01

    Full Text Available In France, in the peri-urban context, urban sprawl dynamics are particularly strong with huge population growth as well as a land crisis. The increase and spreading of built-up areas from the city centre towards the periphery takes place to the detriment of natural and agricultural spaces. The conversion of land with agricultural potential is all the more worrying as it is usually irreversible. The French Ministry of Agriculture therefore needs reliable and repeatable spatial-temporal methods to locate and quantify loss of land at both local and national scales. The main objective of this study was to design a repeatable method to monitor land conversion characterized by artificial sprawl: (i We used an object-based image analysis to extract artificial areas from satellite images; (ii We built an artificial patch that consists of aggregating all the peripheral areas that characterize artificial areas. The “artificialized” patch concept is an innovative extension of the urban patch concept, but differs in the nature of its components and in the continuity distance applied; (iii The diachronic analysis of artificial patch maps enables characterization of artificial sprawl. The method was applied at the scale of four departments (similar to provinces along the coast of Languedoc-Roussillon, in the South of France, based on two satellite datasets, one acquired in 1996–1997 (Indian Remote Sensing and the other in 2009 (RapidEye. In the four departments, we measured an increase in artificial areas of from 113,000 ha in 1997 to 133,000 ha in 2009, i.e., an 18% increase in 12 years. The package comes in the form of a 1/15,000 valid cartography, usable at the scale of a commune (the smallest territorial division used for administrative purposes in France that can be adapted to departmental and regional scales. The method is reproducible in homogenous spatial-temporal terms, so that it could be used periodically to assess changes in land conversion

  10. Rapid methods for detection of bacterial resistance to antibiotics.

    Science.gov (United States)

    March-Rosselló, Gabriel Alberto

    2017-03-01

    The most widely used antibiotic susceptibility testing methods in Clinical Microbiology are based on the phenotypic detection of antibiotic resistance by measuring bacterial growth in the presence of the antibiotic being tested. These conventional methods take typically 24hours to obtain results. Here we review the main techniques for rapid determination of antibiotic susceptibility. Data obtained with different methods such as molecular techniques, microarrays, commercial methods used in work routine, immunochromatographic methods, colorimetric methods, image methods, nephelometry, MALDI-TOF mass spectrometry, flow cytometry, chemiluminescence and bioluminescence, microfluids and methods based on cell disruption are analysed in detail. Copyright © 2016 Elsevier España, S.L.U. and Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.

  11. A rapid ultrasound particle agglutination method for HIV antibody detection: Comparison with conventional rapid HIV tests.

    Science.gov (United States)

    Bystryak, Simon; Ossina, Natalya

    2017-11-01

    We present the results of the feasibility and preliminary studies on analytical performance of a rapid test for detection of human immunodeficiency virus (HIV) antibodies in human serum or plasma that is an important advance in detecting HIV infection. Current methods for rapid testing of antibodies against HIV are qualitative and exhibit poor sensitivity (limit of detection). In this paper, we describe an ultrasound particle agglutination (UPA) method that leads to a significant increase of the sensitivity of conventional latex agglutination tests for HIV antibody detection in human serum or plasma. The UPA method is based on the use of: 1) a dual mode ultrasound, wherein a first single-frequency mode is used to accelerate the latex agglutination process, and then a second swept-frequency mode of sonication is used to disintegrate non-specifically bound aggregates; and 2) a numerical assessment of results of the agglutination process. The numerical assessment is carried out by optical detection and analysis of moving patterns in the resonator cell during the swept-frequency mode. The single-step UPA method is rapid and more sensitive than the three commercial rapid HIV test kits analyzed in the study: analytical sensitivity of the new UPA method was found to be 510-, 115-, and 80-fold higher than that for Capillus™, Multispot™ and Uni-Gold™ Recombigen HIV antibody rapid test kits, respectively. The newly developed UPA method opens up additional possibilities for detection of a number of clinically significant markers in point-of-care settings. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Genomewide rapid association using mixed model and regression: A fast and simple method for genomewide pedigree-based quantitative trait loci association analysis

    NARCIS (Netherlands)

    Y.S. Aulchenko (Yurii); D.-J. de Koning; C. Haley (Chris)

    2007-01-01

    textabstractFor pedigree-based quantitative trait loci (QTL) association analysis, a range of methods utilizing within-family variation such as transmission- disequilibrium test (TDT)-based methods have been developed. In scenarios where stratification is not a concern, methods exploiting

  13. Real-time PCR-based method for the rapid detection of extended RAS mutations using bridged nucleic acids in colorectal cancer.

    Science.gov (United States)

    Iida, Takao; Mizuno, Yukie; Kaizaki, Yasuharu

    2017-10-27

    Mutations in RAS and BRAF are predictors of the efficacy of anti-epidermal growth factor receptor (EGFR) therapy in patients with metastatic colorectal cancer (mCRC). Therefore, simple, rapid, cost-effective methods to detect these mutations in the clinical setting are greatly needed. In the present study, we evaluated BNA Real-time PCR Mutation Detection Kit Extended RAS (BNA Real-time PCR), a real-time PCR method that uses bridged nucleic acid clamping technology to rapidly detect mutations in RAS exons 2-4 and BRAF exon 15. Genomic DNA was extracted from 54 formalin-fixed paraffin-embedded (FFPE) tissue samples obtained from mCRC patients. Among the 54 FFPE samples, BNA Real-time PCR detected 21 RAS mutations (38.9%) and 5 BRAF mutations (9.3%), and the reference assay (KRAS Mutation Detection Kit and MEBGEN™ RASKET KIT) detected 22 RAS mutations (40.7%). The concordance rate of detected RAS mutations between the BNA Real-time PCR assay and the reference assays was 98.2% (53/54). The BNA Real-time PCR assay proved to be a more simple, rapid, and cost-effective method for detecting KRAS and RAS mutations compared with existing assays. These findings suggest that BNA Real-time PCR is a valuable tool for predicting the efficacy of early anti-EGFR therapy in mCRC patients. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Rapid flow-based peptide synthesis.

    Science.gov (United States)

    Simon, Mark D; Heider, Patrick L; Adamo, Andrea; Vinogradov, Alexander A; Mong, Surin K; Li, Xiyuan; Berger, Tatiana; Policarpo, Rocco L; Zhang, Chi; Zou, Yekui; Liao, Xiaoli; Spokoyny, Alexander M; Jensen, Klavs F; Pentelute, Bradley L

    2014-03-21

    A flow-based solid-phase peptide synthesis methodology that enables the incorporation of an amino acid residue every 1.8 min under automatic control or every 3 min under manual control is described. This is accomplished by passing a stream of reagent through a heat exchanger into a low volume, low backpressure reaction vessel, and through a UV detector. These features enable continuous delivery of heated solvents and reagents to the solid support at high flow rate, thereby maintaining maximal concentration of reagents in the reaction vessel, quickly exchanging reagents, and eliminating the need to rapidly heat reagents after they have been added to the vessel. The UV detector enables continuous monitoring of the process. To demonstrate the broad applicability and reliability of this method, it was employed in the total synthesis of a small protein, as well as dozens of peptides. The quality of the material obtained with this method is comparable to that for traditional batch methods, and, in all cases, the desired material was readily purifiable by RP-HPLC. The application of this method to the synthesis of the 113-residue Bacillus amyloliquefaciens RNase and the 130-residue DARPin pE59 is described in the accompanying manuscript. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Rapid and selective method for quantitation of metronidazole in pharmaceuticals.

    Science.gov (United States)

    Sanyal, A K

    1988-01-01

    A selective and highly sensitive assay for N-1-substituted nitroimidazoles has been modified and adapted for rapid estimation of metronidazole in pharmaceuticals. The color reaction is based on diazotization of sulfanilamide with the nitrite ions liberated by alkaline hydrolysis of metronidazole and subsequent coupling of the diazonium salt with N-1-(naphthyl)-ethylenediamine dihydrochloride. This method is applicable for the assay of benzoyl metronidazole in oral suspension. Officially recommended excipients and preservatives do not interfere.

  16. Evaluation of a Rapid Method of Determination of Plasma Fibrinogen

    Science.gov (United States)

    Thomson, G. W.; McSherry, B. J.; Valli, V. E. O.

    1974-01-01

    An evaluation was made of a rapid semiautomated method of determining fibrinogen levels in bovine plasma. This method, the fibrometer method of Morse, Panek and Menga (8), is based on the principle that when thrombin is added to suitably diluted plasma the time of clotting is linearly related to the fibrinogen concentration. A standard curve prepared using bovine plasma had an r value of .9987 and analysis of variance showed there was no significant deviation from regression. A comparison of the fibrometer method and the biuret method of Ware, Guest and Seegers done on 158 bovine plasma samples showed good correlation between the two methods. It was concluded that the fibrometer method does measure bovine fibrinogen and has considerable merit for use in clinical diseases of cattle. PMID:4277474

  17. A simple and rapid method for determining transgenic cotton plants.

    Science.gov (United States)

    Zhang, Baohong; Wang, Hongmei; Liu, Fang; Wang, Qinglian

    2013-01-01

    Determining transgenic events is a critical step for obtaining transgenic plants as well as the later stage of application. Traditional methods, such as Northern blotting and qRT-PCR, for determining transgenic events either require radioactively labeled substrates, expensive instruments, or long-time commitments, which result in lab and time-consuming as well as expensive costs. These methods also require destroying the transgenic events. In this chapter, we present a simple and rapid method for determining transgenic cotton plants in both laboratory and field conditions. This method is based on the sensitivity of transgenic and non-transgenic plants to a specific chemical, such as antibiotics or herbicides. This method will facilitate the screening of transgenic events, save time, reduce cost, and speed up the application of transgenic technology on cotton breeding and production. More important, this is a nondestructive bioassay method; the transgenic plants can be transferred into greenhouse or field for the later study after the detection process.

  18. A rapid method for the detection of foodborne pathogens by extraction of a trace amount of DNA from raw milk based on label-free amino-modified silica-coated magnetic nanoparticles and polymerase chain reaction

    Science.gov (United States)

    A method based on amino-modified silica-coated magnetic nanoparticles (ASMNPs) and polymerase chain reaction (PCR) was developed to rapidly and sensitively detect foodborne pathogens in raw milk. After optimizing parameters such as pH, temperature, and time, a trace amount of genomic DNA of pathogen...

  19. Rapid solidification of Nb-base alloys

    Science.gov (United States)

    Gokhale, A. B.; Javed, K. R.; Abbaschian, G. J.; Lewis, R. E.

    1988-01-01

    New Nb-base alloys are of interest for aerospace structural applications at high temperatures, viz, 800 to 1650 C. Fundamental information regarding the effects of rapid solidification in achieving greatly refined microstructures, extended solid solubility, suppression of embrittling equilibrium phases, and formation of new phases is desired in a number of Nb-X alloys. The microstructures and selected properties of Nb-Si and other Nb-base alloys are presented for materials both rapidly quenched from the equilibrium liquidus and rapidly solidified following deep supercooling. Electromagnetic levitation was used to achieve melting and supercooling in a containerless inert gas environment. A variety of solidification conditions were employed including splatting or drop casting of supercooled samples. The morphology and composition of phases formed are discussed in terms of both solidification history and bulk composition.

  20. Evaluation of a PfHRP-2 based rapid diagnostic test versus microscopy method among HIV-positive and unknown serology patients in Ouagadougou, Burkina Faso.

    Science.gov (United States)

    Andreoli, Arianna; Giorgetti, Pier Francesco; Pietra, Virginio; Melzani, Alessia; Seni, Wetien; Castelli, Francesco; Simpore, Jaques

    2015-04-01

    We evaluated the performance of a malaria rapid diagnostic test (RDT; Malaria Quick Test(®); Cypress Diagnostic) compared with the standard thick-smear microscopy method using blood samples from human immunodeficiency virus (HIV)-infected individuals and individuals of unknown HIV status collected in Ouagadougou, Burkina Faso. Our results show that 42.1% of 114 HIV-infected patients were concordantly RDT- and thick smear-positive, and 55.3% were concordantly negative. Sensitivity and specificity of the RDT test were 100.0% and 95.4%, respectively, with 5.9% false-positive results and a total agreement of 97.4%; 127 patients with unknown HIV serology were analyzed; of them, 40.9% were RDT- and thick smear-positive, and 46.4% concordantly negative. Sensitivity and specificity were 100.0% and 78.6%, respectively, with 23.5% false-positive results and a total agreement of 87.4%. Malaria Quick Test(®) is rapid and effective for the diagnosis of malaria and has a high sensitivity, confirming its use in general and HIV patients in particular. © The American Society of Tropical Medicine and Hygiene.

  1. Rapid method for detection of salmonella in meat

    DEFF Research Database (Denmark)

    2016-01-01

    The present invention relates to a rapid method for the detection of Salmonella in meat as well as to a kit for performing said method. The method provides a time-to-result of less than 8 hours.......The present invention relates to a rapid method for the detection of Salmonella in meat as well as to a kit for performing said method. The method provides a time-to-result of less than 8 hours....

  2. Preparing Silica Aerogel Monoliths via a Rapid Supercritical Extraction Method

    Science.gov (United States)

    Gorka, Caroline A.

    2014-01-01

    A procedure for the fabrication of monolithic silica aerogels in eight hours or less via a rapid supercritical extraction process is described. The procedure requires 15-20 min of preparation time, during which a liquid precursor mixture is prepared and poured into wells of a metal mold that is placed between the platens of a hydraulic hot press, followed by several hours of processing within the hot press. The precursor solution consists of a 1.0:12.0:3.6:3.5 x 10-3 molar ratio of tetramethylorthosilicate (TMOS):methanol:water:ammonia. In each well of the mold, a porous silica sol-gel matrix forms. As the temperature of the mold and its contents is increased, the pressure within the mold rises. After the temperature/pressure conditions surpass the supercritical point for the solvent within the pores of the matrix (in this case, a methanol/water mixture), the supercritical fluid is released, and monolithic aerogel remains within the wells of the mold. With the mold used in this procedure, cylindrical monoliths of 2.2 cm diameter and 1.9 cm height are produced. Aerogels formed by this rapid method have comparable properties (low bulk and skeletal density, high surface area, mesoporous morphology) to those prepared by other methods that involve either additional reaction steps or solvent extractions (lengthier processes that generate more chemical waste).The rapid supercritical extraction method can also be applied to the fabrication of aerogels based on other precursor recipes. PMID:24637334

  3. Rapid Enzymatic Method for Pectin Methyl Esters Determination

    Directory of Open Access Journals (Sweden)

    Lucyna Łękawska-Andrinopoulou

    2013-01-01

    Full Text Available Pectin is a natural polysaccharide used in food and pharma industries. Pectin degree of methylation is an important parameter having significant influence on pectin applications. A rapid, fully automated, kinetic flow method for determination of pectin methyl esters has been developed. The method is based on a lab-made analyzer using the reverse flow-injection/stopped flow principle. Methanol is released from pectin by pectin methylesterase in the first mixing coil. Enzyme working solution is injected further downstream and it is mixed with pectin/pectin methylesterase stream in the second mixing coil. Methanol is oxidized by alcohol oxidase releasing formaldehyde and hydrogen peroxide. This reaction is coupled to horse radish peroxidase catalyzed reaction, which gives the colored product 4-N-(p-benzoquinoneimine-antipyrine. Reaction rate is proportional to methanol concentration and it is followed using Ocean Optics USB 2000+ spectrophotometer. The analyzer is fully regulated by a lab written LabVIEW program. The detection limit was 1.47 mM with an analysis rate of 7 samples h−1. A paired t-test with results from manual method showed that the automated method results are equivalent to the manual method at the 95% confidence interval. The developed method is rapid and sustainable and it is the first application of flow analysis in pectin analysis.

  4. Capillary electrophoresis coupled with inductively coupled mass spectrometry as an alternative to cloud point extraction based methods for rapid quantification of silver ions and surface coated silver nanoparticles.

    Science.gov (United States)

    Qu, Haiou; Mudalige, Thilak K; Linder, Sean W

    2016-01-15

    Speciation and accurate quantification of ionic silver and metallic silver nanoparticles are critical to investigate silver toxicity and to determine the shelf-life of products that contain nano silver under various storage conditions. We developed a rapid method for quantification of silver ions and silver nanoparticles using capillary electrophoresis (CE) interfaced with inductively-coupled plasma mass spectrometry (ICPMS). The addition of 2-mercaptopropionylglycine (tiopronin) to the background electrolyte was used to facilitate the chromatographic separation of ionic silver and maintain the oxidation state of silver. The obtained limits of detection were 0.05 μg kg(-1) of silver nanoparticles and 0.03 μg kg(-1) of ionic silver. Nanoparticles of varied sizes (10-110 nm) with different surface coating, including citrate acid, lipoic acid, polyvinylpyrrolidone and bovine serum albumin (BSA) were successfully analyzed. Particularly good recoveries (>93%) were obtained for both ionic silver and silver nanoparticle in the presence of excess amount of BSA. The method was further tested with six commercially available dietary supplements which varied in concentration and matrix components. The summed values of silver ions and silver nanoparticles correlated well with the total silver concentration determined by ICPMS after acid digestion. This method can serve as an alternative to cloud point extraction technique when the extraction efficiency for protein coated nanoparticles is low. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Rapid and accurate assessment of GPCR-ligand interactions Using the fragment molecular orbital-based density-functional tight-binding method.

    Science.gov (United States)

    Morao, Inaki; Fedorov, Dmitri G; Robinson, Roger; Southey, Michelle; Townsend-Nicholson, Andrea; Bodkin, Mike J; Heifetz, Alexander

    2017-09-05

    The reliable and precise evaluation of receptor-ligand interactions and pair-interaction energy is an essential element of rational drug design. While quantum mechanical (QM) methods have been a promising means by which to achieve this, traditional QM is not applicable for large biological systems due to its high computational cost. Here, the fragment molecular orbital (FMO) method has been used to accelerate QM calculations, and by combining FMO with the density-functional tight-binding (DFTB) method we are able to decrease computational cost 1000 times, achieving results in seconds, instead of hours. We have applied FMO-DFTB to three different GPCR-ligand systems. Our results correlate well with site directed mutagenesis data and findings presented in the published literature, demonstrating that FMO-DFTB is a rapid and accurate means of GPCR-ligand interactions. © 2017 Authors. Journal of Computational Chemistry Published by Wiley Periodicals, Inc. © 2017 Authors. Journal of Computational Chemistry Published by Wiley Periodicals, Inc.

  6. A rapid DNA extraction method suitable for human papillomavirus detection.

    Science.gov (United States)

    Brestovac, Brian; Wong, Michelle E; Costantino, Paul S; Groth, David

    2014-04-01

    Infection with oncogenic human papillomavirus (HPV) genotypes is necessary for the development of cervical cancer. Testing for HPV DNA from liquid based cervical samples can be used as an adjunct to traditional cytological screening. In addition there are ongoing viral load, genotyping, and prevalence studies. Therefore, a sensitive DNA extraction method is needed to maximize the efficiency of HPV DNA detection. The XytXtract Tissue kit is a DNA extraction kit that is rapid and so could be useful for HPV testing, particularly in screening protocols. This study was undertaken to determine the suitability of this method for HPV detection. DNA extraction from HeLa and Caski cell lines containing HPV 18 and 16 respectively together with DNA from five liquid based cervical samples were used in a HPV PCR assay. DNA was also extracted using the QIAamp DNA mini kit (Qiagen, Hilden, Germany) as a comparison. DNA extracts were serially diluted and assayed. HPV DNA was successfully detected in cell lines and cervical samples using the XytXtract Tissue kit. In addition, the XytXtract method was found to be more sensitive than the QIAmp method as determined by a dilution series of the extracted DNA. While the XytXtract method is a closed, the QIAamp method uses a spin column with possible loss of DNA through DNA binding competition of the matrix, which could impact on the final extraction efficiency. The XytXtract is a cheap, rapid and efficient method for extracting HPV DNA from both cell lines and liquid based cervical samples. © 2014 Wiley Periodicals, Inc.

  7. Field trial of the RTM dipstick method for the rapid diagnosis of malaria based on the detection of Plasmodium falciparum HRP-2 antigen in whole blood.

    Science.gov (United States)

    Wolday, D; Balcha, F; Fessehaye, G; Birku, Y; Shepherd, A

    2001-01-01

    The performance of the Quorum RapidTest Malaria (RTM) dipstick method that detects Plasmodium falciparum histidine-rich protein-2 (PfHRP-2) antigen in whole blood was evaluated in a malaria endemic area. Results were compared with conventional Giemsa-stained blood films. Of 306 people tested 37.9% (116/306) were found to be parasitaemic; of these 66.4% (77/116) were P. vivax and 32.8% (38/116) were P. falciparum infections. There was only one (0.9%) mixed P. falciparum plus P. vivax infection. The RTM test was positive in 35/36 patients with P. falciparum identified on blood smear examination, resulting in a sensitivity of 97.2% [95% confidence interval (CI): 91.6-102.8%]. Specificity was 96.3% (95% CI: 93.9-98.6%). The RTM test had a positive predictive value of 77.8% (95% CI: 65.7-89.9%) and a negative predictive value of 99.6% (95% CI: 98.4-100.8%). Of the 10 false positives, seven reported recent malaria episode and treatment, indicating persistence of antigenaemia. If these were assumed truly infected, the positive predictive value is increased to 93.3% (95% CI: 85.8-100.8%). The RTM test was positive in all seven P. falciparum infections with gametocytes and one mixed infection, but was negative in all falciparum gametocytes and relapsing fever cases. All but one P. vivax infection gave negative result on the RTM test. The RTM test missed one patient with parasitaemia. The test is highly sensitive and specific requiring no instrument or trained personnel. It appears to be a very useful tool for rapid diagnosis of malaria, especially in the rural health institutions with limited diagnostic facilities.

  8. ClearColi BL21(DE3)-based expression of Zika virus antigens illustrates a rapid method of antibody production against emerging pathogens.

    Science.gov (United States)

    Viranaicken, Wildriss; Nativel, Brice; Krejbich-Trotot, Pascale; Harrabi, Wissal; Bos, Sandra; El Kalamouni, Chaker; Roche, Marjolaine; Gadea, Gilles; Desprès, Philippe

    2017-11-01

    Available rapid, simple and accurate methods for detection and diagnosis of emerging viral diseases are required. Recently, there was an urgent need for specific antibodies against mosquito-borne Zika virus (ZIKV), which is an emerging zoonotic disease of medical concern in different regions of the world. Here, we showed that overexpression of ZIKV antigens in ClearColi BL21(DE3), a bacteria strain expressing a non-endotoxic form of LPS, is suitable for the production of specific ZIKV antisera. Two major ZIKV antigenic domains, the domain III from envelope E glycoprotein, which brings the virus-specific epitopes, and the N-terminal region of nonstructural NS1 glycoprotein, which is responsible for pathophysiological conditions, were overexpressed in ClearColi BL21(DE3). Immunization of adult rat with insoluble recombinant ZIKV antigens in inclusion bodies resulted in the production of specific antibodies in a few weeks. Anti-E and anti-NS1 antibodies are efficient as biological tools for ZIKV detection by indirect ELISA and immunoblot assay. This method could successfully be applied to any emerging viruses. Copyright © 2017 Elsevier B.V. and Société Française de Biochimie et Biologie Moléculaire (SFBBM). All rights reserved.

  9. SIMS: a hybrid method for rapid conformational analysis.

    Directory of Open Access Journals (Sweden)

    Bryant Gipson

    Full Text Available Proteins are at the root of many biological functions, often performing complex tasks as the result of large changes in their structure. Describing the exact details of these conformational changes, however, remains a central challenge for computational biology due the enormous computational requirements of the problem. This has engendered the development of a rich variety of useful methods designed to answer specific questions at different levels of spatial, temporal, and energetic resolution. These methods fall largely into two classes: physically accurate, but computationally demanding methods and fast, approximate methods. We introduce here a new hybrid modeling tool, the Structured Intuitive Move Selector (sims, designed to bridge the divide between these two classes, while allowing the benefits of both to be seamlessly integrated into a single framework. This is achieved by applying a modern motion planning algorithm, borrowed from the field of robotics, in tandem with a well-established protein modeling library. sims can combine precise energy calculations with approximate or specialized conformational sampling routines to produce rapid, yet accurate, analysis of the large-scale conformational variability of protein systems. Several key advancements are shown, including the abstract use of generically defined moves (conformational sampling methods and an expansive probabilistic conformational exploration. We present three example problems that sims is applied to and demonstrate a rapid solution for each. These include the automatic determination of "active" residues for the hinge-based system Cyanovirin-N, exploring conformational changes involving long-range coordinated motion between non-sequential residues in Ribose-Binding Protein, and the rapid discovery of a transient conformational state of Maltose-Binding Protein, previously only determined by Molecular Dynamics. For all cases we provide energetic validations using well

  10. Rapid assessment methods in eye care: An overview

    Directory of Open Access Journals (Sweden)

    Srinivas Marmamula

    2012-01-01

    Full Text Available Reliable information is required for the planning and management of eye care services. While classical research methods provide reliable estimates, they are prohibitively expensive and resource intensive. Rapid assessment (RA methods are indispensable tools in situations where data are needed quickly and where time- or cost-related factors prohibit the use of classical epidemiological surveys. These methods have been developed and field tested, and can be applied across almost the entire gamut of health care. The 1990s witnessed the emergence of RA methods in eye care for cataract, onchocerciasis, and trachoma and, more recently, the main causes of avoidable blindness and visual impairment. The important features of RA methods include the use of local resources, simplified sampling methodology, and a simple examination protocol/data collection method that can be performed by locally available personnel. The analysis is quick and easy to interpret. The entire process is inexpensive, so the survey may be repeated once every 5-10 years to assess the changing trends in disease burden. RA survey methods are typically linked with an intervention. This article provides an overview of the RA methods commonly used in eye care, and emphasizes the selection of appropriate methods based on the local need and context.

  11. More rapid edgewise crush test methods

    Science.gov (United States)

    Thomas J. Urbanik; Arthur H. Catlin; Davide R. Friedman; Richard C. Lund

    1993-01-01

    The use of paraffin wax to reinforce the loading edges of corrugated fiberboard edge-crush specimens requires that the specimens be reconditioned after waxing. The traditional practice employing a 24-h reconditioning period is a conservative approach based on the moisture response rate of corrugated containers. An interlaboratory study was conducted to determine the...

  12. Verification of rapid method for estimation of added food colorant type in boiled sausages based on measurement of cross section color

    Science.gov (United States)

    Jovanović, J.; Petronijević, R. B.; Lukić, M.; Karan, D.; Parunović, N.; Branković-Lazić, I.

    2017-09-01

    During the previous development of a chemometric method for estimating the amount of added colorant in meat products, it was noticed that the natural colorant most commonly added to boiled sausages, E 120, has different CIE-LAB behavior compared to artificial colors that are used for the same purpose. This has opened the possibility of transforming the developed method into a method for identifying the addition of natural or synthetic colorants in boiled sausages based on the measurement of the color of the cross-section. After recalibration of the CIE-LAB method using linear discriminant analysis, verification was performed on 76 boiled sausages, of either frankfurters or Parisian sausage types. The accuracy and reliability of the classification was confirmed by comparison with the standard HPLC method. Results showed that the LDA + CIE-LAB method can be applied with high accuracy, 93.42 %, to estimate food color type in boiled sausages. Natural orange colors can give false positive results. Pigments from spice mixtures had no significant effect on CIE-LAB results.

  13. An automated image-based method of 3D subject-specific body segment parameter estimation for kinetic analyses of rapid movements.

    Science.gov (United States)

    Sheets, Alison L; Corazza, Stefano; Andriacchi, Thomas P

    2010-01-01

    Accurate subject-specific body segment parameters (BSPs) are necessary to perform kinetic analyses of human movements with large accelerations, or no external contact forces or moments. A new automated topographical image-based method of estimating segment mass, center of mass (CM) position, and moments of inertia is presented. Body geometry and volume were measured using a laser scanner, then an automated pose and shape registration algorithm segmented the scanned body surface, and identified joint center (JC) positions. Assuming the constant segment densities of Dempster, thigh and shank masses, CM locations, and moments of inertia were estimated for four male subjects with body mass indexes (BMIs) of 19.7-38.2. The subject-specific BSP were compared with those determined using Dempster and Clauser regression equations. The influence of BSP and BMI differences on knee and hip net forces and moments during a running swing phase were quantified for the subjects with the smallest and largest BMIs. Subject-specific BSP for 15 body segments were quickly calculated using the image-based method, and total subject masses were overestimated by 1.7-2.9%.When compared with the Dempster and Clauser methods, image-based and regression estimated thigh BSP varied more than the shank parameters. Thigh masses and hip JC to thigh CM distances were consistently larger, and each transverse moment of inertia was smaller using the image-based method. Because the shank had larger linear and angular accelerations than the thigh during the running swing phase, shank BSP differences had a larger effect on calculated intersegmental forces and moments at the knee joint than thigh BSP differences did at the hip. It was the net knee kinetic differences caused by the shank BSP differences that were the largest contributors to the hip variations. Finally, BSP differences produced larger kinetic differences for the subject with larger segment masses, suggesting that parameter accuracy is more

  14. Development of an extraction method based on new porous organogel materials coupled with liquid chromatography-mass spectrometry for the rapid quantification of bisphenol A in urine.

    Science.gov (United States)

    ter Halle, Alexandra; Claparols, Catherine; Garrigues, Jean Christophe; Franceschi-Messant, Sophie; Perez, Emile

    2015-10-02

    A new method based on the use of porous organogel materials in combination with liquid chromatography-tandem mass spectrometry (LC-MS-MS) was assessed for the quantification of trace contaminants in complex matrices. As a demonstration of the use of these new materials, the contaminant chosen as a model was bisphenol A (BPA) and its extraction was investigated in urine. Organogel materials consist of an organic solvent immobilized by an organogelator. The composition of the organogel materials was optimized in terms of extraction efficiency and compatibility with LC-MS-MS. Porosity was introduced into the organogel by means of the particulate leaching method using sugar crystals. This new absorbing material is simple to use; the extraction method is reduced to a few steps. The originality of the method lies in the complete dissolution of the material for analysis by LC-MS-MS. The matrix effect of the organogel components was studied and was found to be minimal in atmospheric-pressure chemical ionization (APCI) compared to electrospray ionization (ESI) in negative mode. The influence of matrix components on the extraction was investigated by working with different media (acidified water, synthetic urine, horse urine and human urine). The partition coefficient was not affected within the margin of error (±0.1). After optimization, bisphenol A recoveries from urine samples reached 80%. The actual concentration factor was 10. The relative standard deviation (RSD, n=6) for the extraction and determination of BPA in horse urine spiked at 10ngmL(-1) was 9%. Tests with spiked human urine showed that the extraction performances were the same as with the solutions tested previously. The use of porous organogel allowed a fast, simple, sensitive, robust, green method to be developed for the determination of trace contaminants in complex matrices. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. A method for rapid similarity analysis of RNA secondary structures

    Directory of Open Access Journals (Sweden)

    Liu Na

    2006-11-01

    Full Text Available Abstract Background Owing to the rapid expansion of RNA structure databases in recent years, efficient methods for structure comparison are in demand for function prediction and evolutionary analysis. Usually, the similarity of RNA secondary structures is evaluated based on tree models and dynamic programming algorithms. We present here a new method for the similarity analysis of RNA secondary structures. Results Three sets of real data have been used as input for the example applications. Set I includes the structures from 5S rRNAs. Set II includes the secondary structures from RNase P and RNase MRP. Set III includes the structures from 16S rRNAs. Reasonable phylogenetic trees are derived for these three sets of data by using our method. Moreover, our program runs faster as compared to some existing ones. Conclusion The famous Lempel-Ziv algorithm can efficiently extract the information on repeated patterns encoded in RNA secondary structures and makes our method an alternative to analyze the similarity of RNA secondary structures. This method will also be useful to researchers who are interested in evolutionary analysis.

  16. Rapid methods for the detection of foodborne bacterial pathogens: principles, applications, advantages and limitations

    Science.gov (United States)

    Law, Jodi Woan-Fei; Ab Mutalib, Nurul-Syakima; Chan, Kok-Gan; Lee, Learn-Han

    2015-01-01

    The incidence of foodborne diseases has increased over the years and resulted in major public health problem globally. Foodborne pathogens can be found in various foods and it is important to detect foodborne pathogens to provide safe food supply and to prevent foodborne diseases. The conventional methods used to detect foodborne pathogen are time consuming and laborious. Hence, a variety of methods have been developed for rapid detection of foodborne pathogens as it is required in many food analyses. Rapid detection methods can be categorized into nucleic acid-based, biosensor-based and immunological-based methods. This review emphasizes on the principles and application of recent rapid methods for the detection of foodborne bacterial pathogens. Detection methods included are simple polymerase chain reaction (PCR), multiplex PCR, real-time PCR, nucleic acid sequence-based amplification (NASBA), loop-mediated isothermal amplification (LAMP) and oligonucleotide DNA microarray which classified as nucleic acid-based methods; optical, electrochemical and mass-based biosensors which classified as biosensor-based methods; enzyme-linked immunosorbent assay (ELISA) and lateral flow immunoassay which classified as immunological-based methods. In general, rapid detection methods are generally time-efficient, sensitive, specific and labor-saving. The developments of rapid detection methods are vital in prevention and treatment of foodborne diseases. PMID:25628612

  17. Rapid Methods for the Detection of Foodborne Bacterial Pathogens: Principles, Applications, Advantages and Limitations

    Directory of Open Access Journals (Sweden)

    Law eJodi Woan-Fei

    2015-01-01

    Full Text Available The incidence of foodborne diseases has increased over the years and resulted in major public health problem globally. Foodborne pathogens can be found in various foods and it is important to detect foodborne pathogens to provide safe food supply and to prevent foodborne diseases. The conventional methods used to detect foodborne pathogen are time consuming and laborious. Hence, a variety of methods have been developed for rapid detection of foodborne pathogens as it is required in many food analyses. Rapid detection methods can be categorized into nucleic acid-based, biosensor-based and immunological-based methods. This review emphasizes on the principles and application of recent rapid methods for the detection of foodborne bacterial pathogens. Detection methods included are simple polymerase chain reaction (PCR, multiplex PCR, real-time PCR, nucleic acid sequence-based amplification (NASBA, loop-mediated isothermal amplification (LAMP and oligonucleotide DNA microarray which classified as nucleic acid-based methods; optical, electrochemical and mass-based biosensors which classified as biosensor-based methods; enzyme-linked immunosorbent assay (ELISA and lateral flow immunoassay which classified as immunological-based methods. In general, rapid detection methods are generally time-efficient, sensitive, specific and labor-saving. The developments of rapid detection methods are vital in prevention and treatment of foodborne diseases.

  18. RAPID SEPARATION METHOD FOR EMERGENCY WATER AND URINE SAMPLES

    Energy Technology Data Exchange (ETDEWEB)

    Maxwell, S.; Culligan, B.

    2008-08-27

    The Savannah River Site Environmental Bioassay Lab participated in the 2008 NRIP Emergency Response program administered by the National Institute for Standards and Technology (NIST) in May, 2008. A new rapid column separation method was used for analysis of actinides and {sup 90}Sr the NRIP 2008 emergency water and urine samples. Significant method improvements were applied to reduce analytical times. As a result, much faster analysis times were achieved, less than 3 hours for determination of {sup 90}Sr and 3-4 hours for actinides. This represents a 25%-33% improvement in analysis times from NRIP 2007 and a {approx}100% improvement compared to NRIP 2006 report times. Column flow rates were increased by a factor of two, with no significant adverse impact on the method performance. Larger sample aliquots, shorter count times, faster cerium fluoride microprecipitation and streamlined calcium phosphate precipitation were also employed. Based on initial feedback from NIST, the SRS Environmental Bioassay Lab had the most rapid analysis times for actinides and {sup 90}Sr analyses for NRIP 2008 emergency urine samples. High levels of potential matrix interferences may be present in emergency samples and rugged methods are essential. Extremely high levels of {sup 210}Po were found to have an adverse effect on the uranium results for the NRIP-08 urine samples, while uranium results for NRIP-08 water samples were not affected. This problem, which was not observed for NRIP-06 or NRIP-07 urine samples, was resolved by using an enhanced {sup 210}Po removal step, which will be described.

  19. RAPID METHOD FOR DETERMINATION OF RADIOSTRONTIUM IN EMERGENCY MILK SAMPLES

    Energy Technology Data Exchange (ETDEWEB)

    Maxwell, S.; Culligan, B.

    2008-07-17

    A new rapid separation method for radiostrontium in emergency milk samples was developed at the Savannah River Site (SRS) Environmental Bioassay Laboratory (Aiken, SC, USA) that will allow rapid separation and measurement of Sr-90 within 8 hours. The new method uses calcium phosphate precipitation, nitric acid dissolution of the precipitate to coagulate residual fat/proteins and a rapid strontium separation using Sr Resin (Eichrom Technologies, Darien, IL, USA) with vacuum-assisted flow rates. The method is much faster than previous method that use calcination or cation exchange pretreatment, has excellent chemical recovery, and effectively removes beta interferences. When a 100 ml sample aliquot is used, the method has a detection limit of 0.5 Bq/L, well below generic emergency action levels.

  20. A rapid and specific colorimetric method for free tryptophan quantification.

    Science.gov (United States)

    Wu, Yinan; Wang, Tianmin; Zhang, Chong; Xing, Xin-Hui

    2018-01-01

    Tryptophan is one of the eight essential amino acids and plays an important role in many biological processes. For its interaction with human health, environment and relevant commercial interest in biotechnology-based production, rapid and specific quantification method for this molecule accessible to common laboratories is badly needed. We herein reported a simple colorimetric method for free tryptophan quantification with 96-well-plate-level throughput. Our protocol firstly converted tryptophan to indole enzymatically by purified tryptophanases and then used reactivity of indole with hydroxylamine to form pink product with absorption peak at 530nm, enabling the quantification of tryptophan with simple spectrometry in just two hours. We presented that this method exhibited a linear detection range from 100μM to 600μM (R(2) = 0.9969) with no detection towards other naturally occurring tryptophan analogs or tryptophan residues in proteins. It was very robust in complicated biological samples, as demonstrated by quantifying the titer of 36 mutated tryptophan-producing strains with Pearson correlation coefficient of 0.93 in contrast to that measured by high performance liquid chromatography (HPLC). Our method should be potent for routine free tryptophan quantification in a high-throughput manner, facilitating studies in medicine, microbiology, food chemistry, metabolic engineering, etc. Copyright © 2017. Published by Elsevier B.V.

  1. Evaluation of Different PCR-Based Assays and LAMP Method for Rapid Detection of Phytophthora infestans by Targeting the Ypt1 Gene

    Directory of Open Access Journals (Sweden)

    Mehran Khan

    2017-10-01

    Full Text Available Late blight, caused by the oomycete Phytophthora infestans, is one of the most devastating diseases affecting potato and tomato worldwide. Early diagnosis of the P. infestans pathogen causing late blight should be the top priority for addressing disease epidemics and management. In this study, we performed a loop-mediated isothermal amplification (LAMP assay, conventional polymerase chain reaction (PCR, nested PCR, and real-time PCR to verify and compare the sensitivity and specificity of the reaction based on the Ypt1 (Ras-related protein gene of P. infestans. In comparison with the PCR-based assays, the LAMP technique led to higher specificity and sensitivity, using uncomplicated equipment with an equivalent time frame. All 43 P. infestans isolates, yielded positive detection results using LAMP assay showing no cross reaction with other Phytophthora spp., oomycetes or fungal pathogens. The LAMP assay yielded the lowest detectable DNA concentration (1.28 × 10-4 ng μL-1, being 10 times more sensitive than nested PCR (1.28 × 10-3 ng μL-1, 100 times more sensitive than real-time PCR (1.28 × 10-2 ng μL-1 and 103 times more sensitive than the conventional PCR assay (1.28 × 10-1 ng μL-1. In the field experiment, the LAMP assay outperformed the other tests by amplifying only diseased tissues (leaf and stem, and showing no positive reaction in healthy tissues. Overall, the LAMP assay developed in this study provides a specific, sensitive, simple, and effective visual method for detection of the P. infestans pathogen, and is therefore suitable for application in early prediction of the disease to reduce the risk of epidemics.

  2. Evaluation of Different PCR-Based Assays and LAMP Method for Rapid Detection of Phytophthora infestans by Targeting the Ypt1 Gene.

    Science.gov (United States)

    Khan, Mehran; Li, Benjin; Jiang, Yue; Weng, Qiyong; Chen, Qinghe

    2017-01-01

    Late blight, caused by the oomycete Phytophthora infestans, is one of the most devastating diseases affecting potato and tomato worldwide. Early diagnosis of the P. infestans pathogen causing late blight should be the top priority for addressing disease epidemics and management. In this study, we performed a loop-mediated isothermal amplification (LAMP) assay, conventional polymerase chain reaction (PCR), nested PCR, and real-time PCR to verify and compare the sensitivity and specificity of the reaction based on the Ypt1 (Ras-related protein) gene of P. infestans. In comparison with the PCR-based assays, the LAMP technique led to higher specificity and sensitivity, using uncomplicated equipment with an equivalent time frame. All 43 P. infestans isolates, yielded positive detection results using LAMP assay showing no cross reaction with other Phytophthora spp., oomycetes or fungal pathogens. The LAMP assay yielded the lowest detectable DNA concentration (1.28 × 10-4 ng μL-1), being 10 times more sensitive than nested PCR (1.28 × 10-3 ng μL-1), 100 times more sensitive than real-time PCR (1.28 × 10-2 ng μL-1) and 103 times more sensitive than the conventional PCR assay (1.28 × 10-1 ng μL-1). In the field experiment, the LAMP assay outperformed the other tests by amplifying only diseased tissues (leaf and stem), and showing no positive reaction in healthy tissues. Overall, the LAMP assay developed in this study provides a specific, sensitive, simple, and effective visual method for detection of the P. infestans pathogen, and is therefore suitable for application in early prediction of the disease to reduce the risk of epidemics.

  3. A multiplex polymerase chain reaction based method for rapid identification of two species of the genus Scolytus Geoffroy (Col: Curculionidae: Scolytinae in Iran

    Directory of Open Access Journals (Sweden)

    S. Amini

    2016-04-01

    Full Text Available Molecular identification is going to be more widespread in taxonomic studies of insects when traditional tools are problematic and time consuming. Identification of bark beetles, as one of the most important pests of forests, based on morphological characteristics is difficult because of their small size and morphological similarities. In the current study, species-specific primers were desi gned to identify two most abundant and morphologically similar bark beetle species Scolytus ensifer Eichhoff 1881 and S. ecksteini Butovitsch 1929, both found on Ulmus minor Miller in north of Iran. These species-specific primers successfully produced a fragment size with 318 bp and 465 bp of mitochondrial cytochrome oxidase 1 (CO1 gene in S. ensifer and S. ecksteini respectively. The results revealed tha t the multiplex polymerase chain reaction using the species-specific primers could amplify a unique band to distinguish these two species so confirmed this method as a convenient and quick tool to identify those two bark beetle species.

  4. A universal, rapid, and inexpensive method for genomic DNA ...

    Indian Academy of Sciences (India)

    MOHAMMED BAQUR SAHIB A. AL-SHUHAIB

    Abstract. There is no 'one' procedure for extracting DNA from the whole blood of both mammals and birds, since each species has a unique property that require different methods to release its own DNA. Therefore, to obtain genomic DNA, a universal, rapid, and noncostly method was developed. A very simple biological ...

  5. Rapid, cost-effective liquid chromatograghic method for the ...

    African Journals Online (AJOL)

    GRACE

    2006-07-03

    Jul 3, 2006 ... 1Department of Medicinal Chemistry and Quality Control, National Institute for Pharmaceutical Research and Development, Abuja,. Nigeria. ... A rapid and cost effective method for the analysis of metronidazole in biological samples was ... effective HPLC method of assaying metronidazole both in.

  6. A universal, rapid, and inexpensive method for genomic DNA ...

    Indian Academy of Sciences (India)

    ... of both mammals and birds, since each species has a unique property that require different methods to release its own DNA. Therefore, to obtain genomic DNA, a universal, rapid, and noncostly method was developed. A very simple biological basis is followed in this procedure, in which, when the bloodis placed in water, ...

  7. School-based surveys of malaria in Oromia Regional State, Ethiopia: a rapid survey method for malaria in low transmission settings

    Directory of Open Access Journals (Sweden)

    Pullan Rachel L

    2011-02-01

    Full Text Available Abstract Background In Ethiopia, malaria transmission is seasonal and unstable, with both Plasmodium falciparum and Plasmodium vivax endemic. Such spatial and temporal clustering of malaria only serves to underscore the importance of regularly collecting up-to-date malaria surveillance data to inform decision-making in malaria control. Cross-sectional school-based malaria surveys were conducted across Oromia Regional State to generate up-to-date data for planning malaria control interventions, as well as monitoring and evaluation of operational programme implementation. Methods Two hundred primary schools were randomly selected using a stratified and weighted sampling frame; 100 children aged five to 18 years were then randomly chosen within each school. Surveys were carried out in May 2009 and from October to December 2009, to coincide with the peak of malaria transmission in different parts of Oromia. Each child was tested for malaria by expert microscopy, their haemoglobin measured and a simple questionnaire completed. Satellite-derived environmental data were used to assess ecological correlates of Plasmodium infection; Bayesian geostatistical methods and Kulldorff's spatial scan statistic were employed to investigate spatial heterogeneity. Results A total 20,899 children from 197 schools provided blood samples, two selected schools were inaccessible and one school refused to participate. The overall prevalence of Plasmodium infection was found to be 0.56% (95% CI: 0.46-0.67%, with 53% of infections due to P. falciparum and 47% due to P. vivax. Of children surveyed, 17.6% (95% CI: 17.0-18.1% were anaemic, while 46% reported sleeping under a mosquito net the previous night. Malaria was found at 30 (15% schools to a maximum elevation of 2,187 metres, with school-level Plasmodium prevalence ranging between 0% and 14.5%. Although environmental variables were only weakly associated with P. falciparum and P. vivax infection, clusters of infection

  8. Multiscale study of the boron and carbon behavior in the fracture zone of the rapidly quenched nickel-based superalloy by the nuclear physics methods of the track and activation autoradiography

    Science.gov (United States)

    Shulga, A. V.

    2016-04-01

    The results of the study of the fracture zone of the rapidly quenched nickel-based superalloy after tensile tests are presented. The main attention was attended to the multiscale investigation of boron and carbon distribution in the area of the cracks propagation by the direct nuclear physics methods of the track and activation autoradiography. Tensile tests were performed at the temperatures up to 1150 °C. The nuclear reactor MEPhI IRT-2000 and cyclotron were applied for the autoradiography studies. Significant depleting of boron in the fracture zone which was revealed can be explained due to the intensive moving of the dislocation.

  9. Methods for Rapid Screening in Woody Plant Herbicide Development

    Directory of Open Access Journals (Sweden)

    William Stanley

    2014-07-01

    Full Text Available Methods for woody plant herbicide screening were assayed with the goal of reducing resources and time required to conduct preliminary screenings for new products. Rapid screening methods tested included greenhouse seedling screening, germinal screening, and seed screening. Triclopyr and eight experimental herbicides from Dow AgroSciences (DAS 313, 402, 534, 548, 602, 729, 779, and 896 were tested on black locust, loblolly pine, red maple, sweetgum, and water oak. Screening results detected differences in herbicide and species in all experiments in much less time (days to weeks than traditional field screenings and consumed significantly less resources (<500 mg acid equivalent per herbicide per screening. Using regression analysis, various rapid screening methods were linked into a system capable of rapidly and inexpensively assessing herbicide efficacy and spectrum of activity. Implementation of such a system could streamline early-stage herbicide development leading to field trials, potentially freeing resources for use in development of beneficial new herbicide products.

  10. Methods and systems for rapid prototyping of high density circuits

    Science.gov (United States)

    Palmer, Jeremy A [Albuquerque, NM; Davis, Donald W [Albuquerque, NM; Chavez, Bart D [Albuquerque, NM; Gallegos, Phillip L [Albuquerque, NM; Wicker, Ryan B [El Paso, TX; Medina, Francisco R [El Paso, TX

    2008-09-02

    A preferred embodiment provides, for example, a system and method of integrating fluid media dispensing technology such as direct-write (DW) technologies with rapid prototyping (RP) technologies such as stereolithography (SL) to provide increased micro-fabrication and micro-stereolithography. A preferred embodiment of the present invention also provides, for example, a system and method for Rapid Prototyping High Density Circuit (RPHDC) manufacturing of solderless connectors and pilot devices with terminal geometries that are compatible with DW mechanisms and reduce contact resistance where the electrical system is encapsulated within structural members and manual electrical connections are eliminated in favor of automated DW traces. A preferred embodiment further provides, for example, a method of rapid prototyping comprising: fabricating a part layer using stereolithography and depositing thermally curable media onto the part layer using a fluid dispensing apparatus.

  11. A taxonomy of rapid reviews links report types and methods to specific decision-making contexts.

    Science.gov (United States)

    Hartling, Lisa; Guise, Jeanne-Marie; Kato, Elisabeth; Anderson, Johanna; Belinson, Suzanne; Berliner, Elise; Dryden, Donna M; Featherstone, Robin; Mitchell, Matthew D; Motu'apuaka, Makalapua; Noorani, Hussein; Paynter, Robin; Robinson, Karen A; Schoelles, Karen; Umscheid, Craig A; Whitlock, Evelyn

    2015-12-01

    Describe characteristics of rapid reviews and examine the impact of methodological variations on their reliability and validity. We conducted a literature review and interviews with organizations that produce rapid reviews or related products to identify methods, guidance, empiric evidence, and current practices. We identified 36 rapid products from 20 organizations (production time, 5 minutes to 8 months). Methods differed from systematic reviews at all stages. As time frames increased, methods became more rigorous; however, restrictions on database searching, inclusion criteria, data extracted, and independent dual review remained. We categorized rapid products based on extent of synthesis. "Inventories" list what evidence is available. "Rapid responses" present best available evidence with no formal synthesis. "Rapid reviews" synthesize the quality of and findings from the evidence. "Automated approaches" generate meta-analyses in response to user-defined queries. Rapid products rely on a close relationship with end users and support specific decisions in an identified time frame. Limited empiric evidence exists comparing rapid and systematic reviews. Rapid products have tremendous methodological variation; categorization based on time frame or type of synthesis reveals patterns. The similarity across rapid products lies in the close relationship with the end user to meet time-sensitive decision-making needs. Copyright © 2015 Elsevier Inc. All rights reserved.

  12. A new rapid method for rockfall energies and distances estimation

    Science.gov (United States)

    Giacomini, Anna; Ferrari, Federica; Thoeni, Klaus; Lambert, Cedric

    2016-04-01

    and distances at the base to block and slope features. The validation of the proposed approach was conducted by comparing predictions to experimental data collected in the field and gathered from the scientific literature. The method can be used for both natural and constructed slopes and easily extended to more complicated and articulated slope geometries. The study shows its great potential for a quick qualitative hazard assessment providing indication about impact energy and horizontal distance of the first impact at the base of a rock cliff. Nevertheless, its application cannot substitute a more detailed quantitative analysis required for site-specific design of mitigation measures. Acknowledgements The authors gratefully acknowledge the financial support of the Australian Coal Association Research Program (ACARP). References Dorren, L.K.A. (2003) A review of rockfall mechanics and modelling approaches, Progress in Physical Geography 27(1), 69-87. Agliardi, F., Crosta, G.B., Frattini, P. (2009) Integrating rockfall risk assessment and countermeasure design by 3D modelling techniques. Natural Hazards and Earth System Sciences 9(4), 1059-1073. Ferrari, F., Thoeni, K., Giacomini, A., Lambert, C. (2016) A rapid approach to estimate the rockfall energies and distances at the base of rock cliffs. Georisk, DOI: 10.1080/17499518.2016.1139729.

  13. A rapid ATR-FTIR spectroscopic method for detection of sibutramine adulteration in tea and coffee based on hierarchical cluster and principal component analyses.

    Science.gov (United States)

    Cebi, Nur; Yilmaz, Mustafa Tahsin; Sagdic, Osman

    2017-08-15

    Sibutramine may be illicitly included in herbal slimming foods and supplements marketed as "100% natural" to enhance weight loss. Considering public health and legal regulations, there is an urgent need for effective, rapid and reliable techniques to detect sibutramine in dietetic herbal foods, teas and dietary supplements. This research comprehensively explored, for the first time, detection of sibutramine in green tea, green coffee and mixed herbal tea using ATR-FTIR spectroscopic technique combined with chemometrics. Hierarchical cluster analysis and PCA principle component analysis techniques were employed in spectral range (2746-2656cm -1 ) for classification and discrimination through Euclidian distance and Ward's algorithm. Unadulterated and adulterated samples were classified and discriminated with respect to their sibutramine contents with perfect accuracy without any false prediction. The results suggest that existence of the active substance could be successfully determined at the levels in the range of 0.375-12mg in totally 1.75g of green tea, green coffee and mixed herbal tea by using FTIR-ATR technique combined with chemometrics. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Triacylglycerol "hand-shape profile" of Argan oil. Rapid and simple UHPLC-PDA-ESI-TOF/MS and HPTLC methods to detect counterfeit Argan oil and Argan-oil-based products.

    Science.gov (United States)

    Pagliuca, Giordana; Bozzi, Carlotta; Gallo, Francesca Romana; Multari, Giuseppina; Palazzino, Giovanna; Porrà, Rita; Panusa, Alessia

    2017-12-02

    The marketing of new argan-based products is greatly increased in the last few years and consequently, it has enhanced the number of control analysis aimed at detecting counterfeit products claiming argan oil as a major ingredient. Argan oil is produced in Morocco and it is quite expensive. Two simple methods for the rapid screening of pure oil and argan-oil based products, focused on the analysis of the triacylglycerol profile, have been developed. A three-minute-run by UHPLC-PDA allows the identification of a pure argan oil, while the same run with the MS detector allows also the analysis of products containing the oil down to 0.03%. On the other hand, by HPTLC the simultaneous analysis of twenty samples, containing argan oil down to 0.5%, can be carried out in a forty-five-minute run. The triglyceride profile of the most common vegetable fats such as almond, coconut, linseed, wheat germ, sunflower, peanut, olive, soybean, rapeseed, hemp oils as well as shea butter used either in cosmetics or commonly added for the counterfeiting of argan oil, has been also investigated. Over sixty products with different formulations and use have been successfully analyzed and argan oil in the 2.4-0.06% concentration range has been quantified. The methods are suitable either for a rapid screening or for quantifying argan oil in different formulations. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Intra-operative rapid diagnostic method based on CK19 mRNA expression for the detection of lymph node metastases in breast cancer

    NARCIS (Netherlands)

    Visser, Mike; Jiwa, Mehdi; Horstman, Anja; Brink, Antoinette A. T. P.; Pol, Rene P.; van Diest, Paul; Snijders, Peter J. F.; Meijer, Chris J. L. M.

    2008-01-01

    Staging by sentinel node (SN) biopsy is the standard procedure for clinically node-negative breast cancer patients. Intra-operative analysis of the SN allows immediate axillary lymph node (ALN) dissection in SN positive patients, but a quick, reliable and reproducible method is lacking. We tested

  16. A rapid screening LC-MS/MS method based on conventional HPLC pumps for the analysis of low molecular weight xenobiotics: application to doping control analysis.

    Science.gov (United States)

    Mazzarino, Monica; de la Torre, Xavier; Botrè, Francesco; Gray, Nicola; Cowan, David

    2010-07-01

    This study presents a fast multi-analyte screening method specifically developed for the detection of xenobiotics in urine. The proposed method allows the screening of several classes of substance in a single chromatographic method with a run-time of 11 min, inclusive of post-run and reconditioning times. Chromatographic separation is achieved in 7.2 min using a reversed-phase 2.7 µm fused-core particle column, generating a back-pressure not exceeding 400 bar and therefore enabling the use of traditional high performance liquid chromatography (HPLC) instruments. The effectiveness of this approach was evaluated, by liquid-chromatography tandem mass spectrometry (LC-MS/MS) in positive electrospray ionization, using 20 blank urine samples spiked with 45 compounds prohibited in sport: 11 diuretics, 16 glucocorticoids, 9 stimulants, 5 anti-oestrogens, as well as formoterol, carboxy-finasteride (previously prohibited by the World Anti-Doping Agency (WADA) in 2008), gestrinone and tetrahydrogestrinone. Qualitative validation shows the proposed method to be specific with no significant interference. All of the analytes considered in this study were clearly distinguishable in urine, with limits of detection ranging from 5 ng/mL to 350 ng/mL, significantly below the Minimum Required Performance Levels (MRPL) set by WADA for the accredited sports anti-doping laboratories. All compounds of interest were separated, including synthetic and endogenous glucocorticoids with similar retention times and fragmentation patterns. Copyright 2010 John Wiley & Sons, Ltd.

  17. Improving Student Understanding of Qualitative and Quantitative Analysis via GC/MS Using a Rapid SPME-Based Method for Determination of Trihalomethanes in Drinking Water

    Science.gov (United States)

    Huang, Shu Rong; Palmer, Peter T.

    2017-01-01

    This paper describes a method for determination of trihalomethanes (THMs) in drinking water via solid-phase microextraction (SPME) GC/MS as a means to develop and improve student understanding of the use of GC/MS for qualitative and quantitative analysis. In the classroom, students are introduced to SPME, GC/MS instrumentation, and the use of MS…

  18. Improving Student Understanding of Qualitative and Quantitative Analysis via GC/MS Using a Rapid SPME-Based Method for Determination of Trihalomethanes in Drinking Water

    Science.gov (United States)

    Huang, Shu Rong; Palmer, Peter T.

    This paper describes a method for determination of trihalomethanes (THMs) in drinking water via solid-phase microextraction (SPME) GC/MS as a means to develop and improve student understanding of the use of GC/MS for qualitative and quantitative analysis. In the classroom, students are introduced to SPME, GC/MS instrumentation, and the use of MS…

  19. RAPID SEPARATION METHOD FOR ACTINIDES IN EMERGENCY SOIL SAMPLES

    Energy Technology Data Exchange (ETDEWEB)

    Maxwell, S.; Culligan, B.; Noyes, G.

    2009-11-09

    A new rapid method for the determination of actinides in soil and sediment samples has been developed at the Savannah River Site Environmental Lab (Aiken, SC, USA) that can be used for samples up to 2 grams in emergency response situations. The actinides in soil method utilizes a rapid sodium hydroxide fusion method, a lanthanum fluoride soil matrix removal step, and a streamlined column separation process with stacked TEVA, TRU and DGA Resin cartridges. Lanthanum was separated rapidly and effectively from Am and Cm on DGA Resin. Vacuum box technology and rapid flow rates are used to reduce analytical time. Alpha sources are prepared using cerium fluoride microprecipitation for counting by alpha spectrometry. The method showed high chemical recoveries and effective removal of interferences. This new procedure was applied to emergency soil samples received in the NRIP Emergency Response exercise administered by the National Institute for Standards and Technology (NIST) in April, 2009. The actinides in soil results were reported within 4-5 hours with excellent quality.

  20. Susceptibility testing of filamentous fungi to amphotericin B by a rapid radiometric method

    Energy Technology Data Exchange (ETDEWEB)

    Merz, W.G.; Fay, D.; Thumar, B.; Dixon, D.

    1984-01-01

    A rapid, radiometric method was developed to determine the susceptibility of filamentous fungi to amphotericin B. The rapid, radiometric method depended on measurement of the inhibition of /sup 24/CO/sub 2/ production in the presence of amphotericin B. Thirty isolates of filamentous fungi were tested by the rapid, radiometric method and a reference agar dilution method. There was 93% agreement between the two methods when an 80% or greater decrease in CO/sub 2/ production was used to calculate the minimal inhibitory concentration with the rapid, radiometric method. Minimal inhibitory concentrations, based on 80% decrease of CO/sub 2/ production, were achieved within 24 h of incubation with all of the fungi tested.

  1. Rapid and robust traffic accident detection based on orientation map

    Science.gov (United States)

    Zhou, Jinglei; Ye, Mao; Ding, Jian; Mao, Songan; Zhang, Huixiong John

    2012-11-01

    Video-based rapid traffic accident detection is very important for intelligent transport systems. Traditional methods are either not fast enough or not stable with working environments. A rapid and environment-adaptive method is proposed. The inspiration of the method is originated from the key observation that the traffic accident brings abundant information on motion directions. This method includes three steps. First, the orientation map for each video frame is constructed based on the optical flows. Then, for each orientation map, the connected regions are formed. An entropy-like energy function is used to measure the orientation information of the connected region. The higher the energy value, the more moving directions exist. The highest measure of these connected regions in each orientation map is considered as its energy measure. Finally, based on the energy sequence of orientation maps, a Gaussian model is established to learn the normal energy fluctuation range for some environment. In the detection process, if the energy of one orientation map burst out of the normal range, it means there exists a traffic accident. The advantages of our method include the fast processing speed, a compact parameter set, and the robustness to the different environments and illuminations. Experimental results confirm the above advantages of the proposed approach.

  2. Rapid method to estimate temperature changes in electronics elements

    Directory of Open Access Journals (Sweden)

    Oborskii G. A., Savel’eva O. S., Shikhireva Yu. V.

    2014-06-01

    Full Text Available Thermal behavior of electronic equipment is the determining factor for performing rapid assessment of the effectiveness of design and operation of the equipment. The assessment method proposed in this article consists in fixation of an infrared video stream from the surface of the device and converting it into a visible flow by means of a thermal imager, splitting it into component colors and their further processing using parabolic transformation. The result of the transformation is the number used as a rapid criterion for estimation of distribution stability of heat in the equipment.

  3. A rapid genotyping method for an obligate fungal pathogen, Puccinia striiformis f.sp. tritici, based on DNA extraction from infected leaf and Multiplex PCR genotyping

    Directory of Open Access Journals (Sweden)

    Enjalbert Jérôme

    2011-07-01

    Full Text Available Abstract Background Puccinia striiformis f.sp. tritici (PST, an obligate fungal pathogen causing wheat yellow/stripe rust, a serious disease, has been used to understand the evolution of crop pathogen using molecular markers. However, numerous questions regarding its evolutionary history and recent migration routes still remains to be addressed, which need the genotyping of a large number of isolates, a process that is limited by both DNA extraction and genotyping methods. To address the two issues, we developed here a method for direct DNA extraction from infected leaves combined with optimized SSR multiplexing. Findings We report here an efficient protocol for direct fungal DNA extraction from infected leaves, avoiding the costly and time consuming step of spore multiplication. The genotyping strategy we propose, amplified a total of 20 SSRs in three Multiplex PCR reactions, which were highly polymorphic and were able to differentiate different PST populations with high efficiency and accuracy. Conclusion These two developments enabled a genotyping strategy that could contribute to the development of molecular epidemiology of yellow rust disease, both at a regional or worldwide scale.

  4. A rapid space-resolved solid-phase microextraction method as a powerful tool to determine contaminants in wine based on their volatility.

    Science.gov (United States)

    Liu, Min; Peng, Qing-Qing; Chen, Yu-Feng; Tang, Qian; Feng, Qing

    2015-06-01

    A novel space-resolved solid phase microextraction (SR-SPME) technique was developed to facilitate simultaneously analyte monitoring within heterogeneous samples. Graphene (G) and graphene oxide (GO) were coated separately to the segmented fibers which were successfully used for the solid-phase microextraction of two contaminants with dramatically different volatility: 2,4,6-trichloroanisole (TCA) and dibutyl phthalate (DBP). The space-resolved fiber showed good precision (5.4%, 6.8%), low detection limits (0.3ng/L, 0.3ng/L), and wide linearity (1.0-250.0ng/L, 1.0-250.0ng/L) under the optimized conditions for TCA and DBP, respectively. The method was applied to simultaneous analysis of the two contaminates with satisfactory recoveries, which were 96.96% and 98.20% for wine samples. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Rapid methods for determination of fluoxetine in pharmaceutical formulations.

    Science.gov (United States)

    Mandrioli, R; Pucci, V; Visini, D; Varani, G; Raggi, M A

    2002-08-01

    Two different analytical methods for the quality control of fluoxetine in commercial formulations have been developed and compared: a spectrofluorimetric method and a capillary zone electrophoretic (CZE) method. The fluorescence emission values were measured at lambda=293 nm when exciting at lambda=230 nm. The CZE method used an uncoated fused-silica capillary and pH 2.5 phosphate buffer as the background electrolyte. The extraction of fluoxetine from the capsules consisted of a simple one-step dissolution with methanol/water, filtration and dilution. Both methods gave satisfactory results in terms of precision; the best results were obtained for the electrophoretic method, with RSD% values always lower than 2.0%. The accuracy was assessed by means of recovery studies, which gave very good results, between 97.5 and 102.6%. Furthermore, both methods also have the advantage of being very rapid.

  6. A physicochemical descriptor based method for effective and rapid screening of dual inhibitors against BACE-1 and GSK-3β as targets for Alzheimer's disease.

    Science.gov (United States)

    Kumar, Akhil; Srivastava, Gaurava; Sharma, Ashok

    2017-12-01

    Due to multifactorial nature of Alzheimer's disease one target-one ligand hypothesis often looks insufficient. BACE-1 and GSK-3β are well established therapeutic drug targets and interaction between BACE-1 and GSK-3β pathways has also been established. Thus, designing of dual inhibitor for these two targets seems rational and may provide effective therapeutic strategies against AD. Recent studies revealed that only two scaffolds i.e. triazinone and curcumin act as a dual inhibitor against BACE-1 and GSK-3β. Thus, this discovery set the path to screen new chemical entities from a vast chemical space (∼1060 compounds) that inhibit both the targets. However, small part of the large chemical space will only show biological activity for specific targets. Virtual screening of large libraries is impractical and computational expensive especially in case of dual inhibitor design. In the case of dual or multi target inhibitor designing, we screened the database for each target that further increases time and resources. In this study we have done physicochemical descriptor based profiling to know the biological relevant chemical space for BACE-1 and GSK-3β inhibitors and proposed the suitable range of important physicochemical properties, occurrence of functional groups. We generated scaffolds tree of known inhibitors of BACE-1 and GSK-3β suggesting the common structure/fragment that can be used to design dual inhibitors. This approach can filter the potential dual inhibitor candidates of BACE-1 and GSK-3β from non inhibitors. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. RAPID TEST METHOD FOR EVALUATION OF ANTIFREEZE ADDITIVE EFFICIENCY

    Directory of Open Access Journals (Sweden)

    S. V. Gushchin

    2015-01-01

    Full Text Available Usage of chemical additives while executing concrete works at negative temperatures is considered as a convenient and economical method. Range of the used antifreeze additives is rather wide. A great number of new additives are advertised but their characteristics have not been practically studied. Evaluation of the antifreeze additive efficiency is unfortunately rather long process and it does not provide comprehensive data on concrete structure formation processes. Due to this development of rapid and comprehensive methodology for construction companies is urgently required.Freezing processes of antifreeze additive aqueous solutions and hardening of cement paste with them have been investigated in the paper. The paper proposes a methodology for determination of freezing point for aqueous solutions of chemical additives of various applications. Identity of  freezing point for a chemical additive aqueous solution and cement paste with an equal concentration of the additive in the paste pore fluid has been determined while taking  calcium nitrate and sodium formate additives as an example. The paper demonstrates the possibility to evaluate efficiency of antifreeze additive action on the basis of kinetics in temperature changes of the cement paste with additives by its consecutive freezing and defrosting.  A methodology for operational evaluation in the field of chemical additive application for concreting items at negative temperatures has been offered in the paper.  The methodology does not require  deficient and expensive test-equipment. It can be applied at ordinary construction companies and it is comprehensible for personnel of low-qualification.  The paper shows the possibility to develop an original methodology for designing concrete structure which is based on operating efficiency determinations  for single and integrated antifreeze additives.

  8. A novel method for rapid in vitro radiobioassay

    Science.gov (United States)

    Crawford, Evan Bogert

    Rapid and accurate analysis of internal human exposure to radionuclides is essential to the effective triage and treatment of citizens who have possibly been exposed to radioactive materials in the environment. The two most likely scenarios in which a large number of citizens would be exposed are the detonation of a radiation dispersal device (RDD, "dirty bomb") or the accidental release of an isotope from an industrial source such as a radioisotopic thermal generator (RTG). In the event of the release and dispersion of radioactive materials into the environment in a large city, the entire population of the city -- including all commuting workers and tourists -- would have to be rapidly tested, both to satisfy the psychological needs of the citizens who were exposed to the mental trauma of a possible radiation dose, and to satisfy the immediate medical needs of those who received the highest doses and greatest levels of internal contamination -- those who would best benefit from rapid, intensive medical care. In this research a prototype rapid screening method to screen urine samples for the presence of up to five isotopes, both individually and in a mixture, has been developed. The isotopes used to develop this method are Co-60, Sr-90, Cs-137, Pu-238, and Am-241. This method avoids time-intensive chemical separations via the preparation and counting of a single sample on multiple detectors, and analyzing the spectra for isotope-specific markers. A rapid liquid-liquid separation using an organic extractive scintillator can be used to help quantify the activity of the alpha-emitting isotopes. The method provides quantifiable results in less than five minutes for the activity of beta/gamma-emitting isotopes when present in the sample at the intervention level as defined by the Centers for Disease Control and Prevention (CDC), and quantifiable results for the activity levels of alpha-emitting isotopes present at their respective intervention levels in approximately 30

  9. Radiometric method for the rapid detection of Leptospira organisms

    Energy Technology Data Exchange (ETDEWEB)

    Manca, N.; Verardi, R.; Colombrita, D.; Ravizzola, G.; Savoldi, E.; Turano, A.

    1986-02-01

    A rapid and sensitive radiometric method for detection of Leptospira interrogans serovar pomona and Leptospira interrogans serovar copenhageni is described. Stuart's medium and Middlebrook TB (12A) medium supplemented with bovine serum albumin, catalase, and casein hydrolysate and labeled with /sup 14/C-fatty acids were used. The radioactivity was measured in a BACTEC 460. With this system, Leptospira organisms were detected in human blood in 2 to 5 days, a notably shorter time period than that required for the majority of detection techniques.

  10. Method for rapidly determining a pulp kappa number using spectrophotometry

    Science.gov (United States)

    Chai, Xin-Sheng; Zhu, Jun Yong

    2002-01-01

    A system and method for rapidly determining the pulp kappa number through direct measurement of the potassium permanganate concentration in a pulp-permanganate solution using spectrophotometry. Specifically, the present invention uses strong acidification to carry out the pulp-permanganate oxidation reaction in the pulp-permanganate solution to prevent the precipitation of manganese dioxide (MnO.sub.2). Consequently, spectral interference from the precipitated MnO.sub.2 is eliminated and the oxidation reaction becomes dominant. The spectral intensity of the oxidation reaction is then analyzed to determine the pulp kappa number.

  11. Rapid coulometric method for the Kjeldahl determination of nitrogen.

    Science.gov (United States)

    Boström, C A; Cedergren, A; Johansson, G; Pettersson, I

    1974-11-01

    A rapid coulometric method for the Kjeldahl determination of nitrogen is described. The samples are digested by means of the Tecator AB digestion system which permits forty samples to be digested at the same time. The digestion products are diluted to 75 ml and 1 ml is coulometrically titrated in 1-2 min: 20-30 determinations can be performed per hour. For substances containing nitrogen in the per cent range the relative standard deviations for eight different substances were 0.1-1%.

  12. A Novel Rapid Method to Determine Cannabis Seed Germination Ability

    OpenAIRE

    吉澤, 政夫; 荒金, 眞佐子; 鈴木, 幸子; 北川, 重美; 中嶋, 順一; 森, 謙一郎; 荻野, 周三; Masao, Yoshizawa; Masako, Aragane; Yukiko, Suzuki; Shigemi, Kitagawa; Jun'ichi, Nakajima; Ken'ichiro, Mori; Shuzo, Ogino; 東京都健康安全研究センター薬用植物園

    2011-01-01

    A novel rapid method to determine cannabis seed germination ability was developed. Cannabis seeds were soaked in water for 15 minutes at 40℃, and germs were removed from the seeds by cracking the shell with tweezers. The germs were soaked in water for 15 minutes at 40℃, and the swollen skin was peeled off. The peeled germs were again soaked in water for 10 minutes at 40℃, and the angles between the seed leaves were measured. Cannabis seeds with angles of the seed leaves exceeding 30 degrees w...

  13. Commercially Available Rapid Methods for Detection of Selected Food-borne Pathogens.

    Science.gov (United States)

    Valderrama, Wladir B; Dudley, Edward G; Doores, Stephanie; Cutter, Catherine N

    2016-07-03

    Generally, the enumeration and isolation of food-borne pathogens is performed using culture-dependent methods. These methods are sensitive, inexpensive, and provide both qualitative and quantitative assessment of the microorganisms present in a sample, but these are time-consuming. For this reason, researchers are developing new techniques that allow detection of food pathogens in shorter period of time. This review identifies commercially available methods for rapid detection and quantification of Listeria monocytogenes, Salmonella spp., Staphylococcus aureus, and Shiga toxin-producing Escherichia coli in food samples. Three categories are discussed: immunologically based methods, nucleic acid-based assays, and biosensors. This review describes the basic mechanism and capabilities of each method, discusses the difficulties of choosing the most convenient method, and provides an overview of the future challenges for the technology for rapid detection of microorganisms.

  14. A simple and rapid analytical method based on solid-phase extraction and liquid chromatography-tandem mass spectrometry for the simultaneous determination of free catecholamines and metanephrines in urine and its application to routine clinical analysis.

    Science.gov (United States)

    Woo, Hye In; Yang, Jeong Soo; Oh, Hyeon Ju; Cho, Yoon Young; Kim, Jae Hyeon; Park, Hyung-Doo; Lee, Soo-Youn

    2016-05-01

    Urinary catecholamines and metanephrines are biochemical indicators of pheochromocytoma. We developed and validated a rapid and precise analytical method based on solid-phase extraction (SPE) and liquid chromatography separation coupled to tandem mass spectrometry (LC-MS/MS) for measuring urinary free catecholamines and metanephrines in a clinical setting. Following SPE purification of catecholamines and metanephrines from urine specimens, chromatographic separation and quantitative detection were performed using LC-MS/MS. The developed method for simultaneous measurement of urinary free catecholamines and metanephrines was validated with clinical urine specimens and was compared with other clinical and biochemical results, including urinary total metanephrines, vanillylmandelic acid (VMA), and plasma free metanephrines. The performance of our newly developed method for measuring urinary free epinephrine (EPI), norepinephrine (NE), dopamine (DA), metanephrine (MN), and normetanephrine (NMN), was acceptable. The recoveries and matrix effects of analytes were 61-107% and 84.5-130.7%. The linear ranges of each analyte were 3.8-2163μg/L, 7.4-2,359μg/L, 5.4-2,825μg/L, 3.5-2,466μg/L, and 3.7-2,569μg/L, and the coefficients of variation (CV) were less than 10% with respect to imprecision. Carryover and sample stability were also validated. Validation using clinical urine specimens by comparison with various biochemical results showed that urinary free metanephrines had comparable sensitivity (100%) and superior specificity (97.1%) to urinary total and plasma free metanephrines. The facile and reliable simultaneous measurement method for urinary free catecholamines and metanephrines using LC-MS/MS developed in this study is helpful in obtaining information about multiple metabolites and is applicable to routine clinical settings for the screening of pheochromocytoma. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights

  15. A simple and rapid molecular method for Leptospira species identification

    NARCIS (Netherlands)

    Ahmed, Ahmed; Anthony, Richard M.; Hartskeerl, Rudy A.

    2010-01-01

    Serological and DNA-based classification systems only have little correlation. Currently serological and molecular methods for characterizing Leptospira are complex and costly restricting their world-wide distribution and use. Ligation mediated amplification combined with microarray analysis

  16. Rapid and simultaneous detection of human hepatitis B virus and hepatitis C virus antibodies based on a protein chip assay using nano-gold immunological amplification and silver staining method

    Directory of Open Access Journals (Sweden)

    Wan Zhixiang

    2005-07-01

    Full Text Available Abstract Background Viral hepatitis due to hepatitis B virus and hepatitis C virus are major public health problems all over the world. Traditional detection methods including polymerase chain reaction (PCR-based assays and enzyme-linked immunosorbent assays (ELISA are expensive and time-consuming. In our assay, a protein chip assay using Nano-gold Immunological Amplification and Silver Staining (NIASS method was applied to detect HBV and HCV antibodies rapidly and simultaneously. Methods Chemically modified glass slides were used as solid supports (named chip, on which several antigens, including HBsAg, HBeAg, HBcAg and HCVAg (a mixture of NS3, NS5 and core antigens were immobilized respectively. Colloidal nano-gold labelled staphylococcal protein A (SPA was used as an indicator and immunogold silver staining enhancement technique was applied to amplify the detection signals, producing black image on array spots, which were visible with naked eyes. To determine the detection limit of the protein chip assay, a set of model arrays in which human IgG was spotted were structured and the model arrays were incubated with different concentrations of anti-IgG. A total of 305 serum samples previously characterized with commercial ELISA were divided into 4 groups and tested in this assay. Results We prepared mono-dispersed, spherical nano-gold particles with an average diameter of 15 ± 2 nm. Colloidal nano-gold-SPA particles observed by TEM were well-distributed, maintaining uniform and stable. The optimum silver enhancement time ranged from 8 to 12 minutes. In our assay, the protein chips could detect serum antibodies against HBsAg, HBeAg, HBcAg and HCVAg with the absence of the cross reaction. In the model arrays, the anti-IgG as low as 3 ng/ml could be detected. The data for comparing the protein chip assay with ELISA indicated that no distinct difference (P > 0.05 existed between the results determined by our assay and ELISA respectively. Conclusion

  17. A rapid method to determine sterol, erythrodiol, and uvaol concentrations in olive oil.

    Science.gov (United States)

    Mathison, Brian; Holstege, Dirk

    2013-05-15

    A rapid, accurate, and efficient method for determining the sterol, uvaol, and erythrodiol concentrations was developed to meet International Olive Council (IOC) certification criteria for extra virgin olive oil (EVOO). The unsaponifiable fraction of the sample (0.2 g) was separated with a diatomaceous earth column, and the sterol and triterpenic dialcohols were isolated with a novel base-activated silica solid-phase extraction (SPE) cartridge cleanup protocol. The improved method and the IOC method provided identical pass/fail results (n = 34) for each of the six sterol and erythrodiol/uvaol IOC criteria used to assess olive oil. This method was validated, and recoveries of stigmasterol (88%) and β-sitosterol (84%) were greater than previously published values obtained using the IOC method. This method requires approximately one-third the time required to complete the IOC method and has great utility for the rapid screening of EVOO to detect adulteration, false labeling, and an inferior product.

  18. Rapid identification of cytokinins by an immunological method

    Energy Technology Data Exchange (ETDEWEB)

    Morris, R.O.; Jameson, P.E.; Morris, J.W. (Univ. of Missouri-Columbia (USA)); Laloue, M. (Centre Nationale de la Recherche Scientifique, Gif-sur-Yvette (France))

    1991-04-01

    A method for rapid identification of bacterial cytokinins has been developed in which cultures are fed ({sup 3}H)adenine, the cytokinins (including, {sup 3}H-labeled cytokinins) are isolated by immunoaffinity chromatography, and analyzed by HPLC with on-line scintillation counting. Analysis of Agrobacterium tumefaciens strains showed that some produced primarily trans-zeatin, whereas others produced primarily trans-zeatin riboside. Pseudomonas syringae pv savastanoi produced mixtures of transzeatin, dihydrozeatin, 1{double prime}-methyl-trans-zeatin riboside, and other unknown cytokinin-like substances. Corynebacterium fascians, produced cis-zeatin, isopentenyladenine and isopentenyladenosine. The technique is designed for qualitative rather than quantitative studies and allows ready identification of bacterial cytokinins. It may also have utility in the study of plant cytokinins if adequate incorporation of label into cytokinin precursor pools can be achieved.

  19. A rapid protection switching method in carrier ethernet ring networks

    Science.gov (United States)

    Yuan, Liang; Ji, Meng

    2008-11-01

    Abstract: Ethernet is the most important Local Area Network (LAN) technology since more than 90% data traffic in access layer is carried on Ethernet. From 10M to 10G, the improving Ethernet technology can be not only used in LAN, but also a good choice for MAN even WAN. MAN are always constructed in ring topology because the ring network could provide resilient path protection by using less resource (fibre or cable) than other network topologies. In layer 2 data networks, spanning tree protocol (STP) is always used to protect transmit link and preventing the formation of logic loop in networks. However, STP cannot guarantee the efficiency of service convergence when link fault happened. In fact, convergent time of networks with STP is about several minutes. Though Rapid Spanning Tree Protocol (RSTP) and Multi-Spanning Tree Protocol (MSTP) improve the STP technology, they still need a couple of seconds to achieve convergence, and can not provide sub-50ms protection switching. This paper presents a novel rapid ring protection method (RRPM) for carrier Ethernet. Unlike other link-fault detection method, it adopts distributed algorithm to detect link fault rapidly (sub-50ms). When networks restore from link fault, it can revert to the original working state. RRPM can provide single ring protection and interconnected ring protection without the formation of super loop. In normal operation, the master node blocks the secondary port for all non-RRPM Ethernet frames belonging to the given RRPM Ring, thereby avoiding a loop in the ring. When link fault happens, the node on which the failure happens moves from the "ring normal" state to the "ring fault" state. It also sends "link down" frame immediately to other nodes and blocks broken port and flushes its forwarding database. Those who receive "link down" frame will flush forwarding database and master node should unblock its secondary port. When the failure restores, the whole ring will revert to the normal state. That is

  20. A method of rapid testing of radioactivity of different materials

    Directory of Open Access Journals (Sweden)

    Yu. Zabulonov

    2016-10-01

    Full Text Available A new method for the detection of low-level ionising radiation in solid, liquid or loose materials, which is based on the use of the Bayesian approach for the estimation of probabilistic parameters and a special statistical criterion, is offered in the present paper. We describe the algorithm and show the advantages of the method. The approach can be effective even in the case of extremely low signals whose intensity is much less than the background radiation.

  1. Method for Rapid Protein Identification in a Large Database

    Directory of Open Access Journals (Sweden)

    Wenli Zhang

    2013-01-01

    Full Text Available Protein identification is an integral part of proteomics research. The available tools to identify proteins in tandem mass spectrometry experiments are not optimized to face current challenges in terms of identification scale and speed owing to the exponential growth of the protein database and the accelerated generation of mass spectrometry data, as well as the demand for nonspecific digestion and post-modifications in complex-sample identification. As a result, a rapid method is required to mitigate such complexity and computation challenges. This paper thus aims to present an open method to prevent enzyme and modification specificity on a large database. This paper designed and developed a distributed program to facilitate application to computer resources. With this optimization, nearly linear speedup and real-time support are achieved on a large database with nonspecific digestion, thus enabling testing with two classical large protein databases in a 20-blade cluster. This work aids in the discovery of more significant biological results, such as modification sites, and enables the identification of more complex samples, such as metaproteomics samples.

  2. Rapid simulation of electromagnetic telemetry using an axisymmetric semianalytical finite element method

    Science.gov (United States)

    Chen, Jiefu; Zeng, Shubin; Dong, Qiuzhao; Huang, Yueqin

    2017-02-01

    An axisymmetric semianalytical finite element method is proposed and employed for rapid simulations of electromagnetic telemetry in layered underground formation. In this method, the layered media is decomposed into several subdomains and the interfaces between subdomains are discretized by conventional finite elements. Then a Riccati equation based high precision integration scheme is applied to exploit the homogeneity along the vertical direction in each layer. This semianalytical finite element scheme is very efficient in modeling electromagnetic telemetry in layered formation. Numerical examples as well as a field case with water based mud as drilling fluid are given to demonstrate the validity and effectiveness of this method.

  3. Rapid magnetic hardening by rapid thermal annealing in NdFeB-based nanocomposites

    Energy Technology Data Exchange (ETDEWEB)

    Chu, K.-T.; Jin, Z Q; Chakka, Vamsi M; Liu, J P [Department of Physics, University of Texas at Arlington, Arlington, TX 76019 (United States)

    2005-11-21

    A systematic study of heat treatments and magnetic hardening of NdFeB-based melt-spun nanocomposite ribbons have been carried out. Comparison was made between samples treated by rapid thermal annealing and by conventional furnace annealing. Heating rates up to 200 K s{sup -1} were adopted in the rapid thermal processing. It was observed that magnetic hardening can be realized in an annealing time as short as 1 s. Coercivity of 10.2 kOe in the nanocomposites has been obtained by rapid thermal annealing for 1 s, and prolonged annealing did not give any increase in coercivity. Detailed results on the effects of annealing time, temperature and heating rate have been obtained. The dependence of magnetic properties on the annealing parameters has been investigated. Structural characterization revealed that there is a close correlation between magnetic hardening and nanostructured morphology. The coercivity mechanism was also studied by analysing the magnetization minor loops.

  4. An economical and combined method for rapid and efficient isolation of fungal DNA.

    Science.gov (United States)

    Lech, T; Syguła-Cholewinska, J; Szostak-Kot, J

    2014-12-18

    DNA isolation is a crucial step of conducting genetic studies in any organism. However, this process is quite difficult when studying fungi because of the need to damage the fungal cell walls of specific structures. In this study, we developed a method for the rapid and efficient isolation of fungal DNA based on simultaneous mechanical and enzymatic cell wall degradation. There are several typical modifications of the standard phenol-chloroform DNA extraction method. This method can be modified to degrade the fungal cell wall. The first step of the presented DNA extraction included manual homogenization in modified lysis buffer. Next, enzymatic digestion using 2 enzymes was conducted, including lyticase and proteinase K. To carefully select the most favorable conditions, we developed an economical, rapid, and reliable method for fungal DNA extraction that ensures both high efficiency and proper purity, which are essential for further analyses.

  5. Rapid new methods for paint collection and lead extraction.

    Science.gov (United States)

    Gutknecht, William F; Harper, Sharon L; Winstead, Wayne; Sorrell, Kristen; Binstock, David A; Salmons, Cynthia A; Haas, Curtis; McCombs, Michelle; Studabaker, William; Wall, Constance V; Moore, Curtis

    2009-01-01

    Chronic exposure of children to lead can result in permanent physiological impairment. In adults, it can cause irritability, poor muscle coordination, and nerve damage to the sense organs and nerves controlling the body. Surfaces coated with lead-containing paints are potential sources of exposure to lead. In April 2008, the U.S. Environmental Protection Agency (EPA) finalized new requirements that would reduce exposure to lead hazards created by renovation, repair, and painting activities, which disturb lead-based paint. On-site, inexpensive identification of lead-based paint is required. Two steps have been taken to meet this challenge. First, this paper presents a new, highly efficient method for paint collection that is based on the use of a modified wood drill bit. Second, this paper presents a novel, one-step approach for quantitatively grinding and extracting lead from paint samples for subsequent lead determination. This latter method is based on the use of a high-revolutions per minute rotor with stator to break up the paint into approximately 50 micron-size particles. Nitric acid (25%, v/v) is used to extract the lead in 95% for real-world paints, National Institute of Standards and Technology's standard reference materials, and audit samples from the American Industrial Hygiene Association's Environmental Lead Proficiency Analytical Testing Program. This quantitative extraction procedure, when paired with quantitative paint sample collection and lead determination, may enable the development of a lead paint test kit that will meet the specifications of the final EPA rule.

  6. Considerations for Task Analysis Methods and Rapid E-Learning Development Techniques

    Directory of Open Access Journals (Sweden)

    Dr. Ismail Ipek

    2014-02-01

    Full Text Available The purpose of this paper is to provide basic dimensions for rapid training development in e-learning courses in education and business. Principally, it starts with defining task analysis and how to select tasks for analysis and task analysis methods for instructional design. To do this, first, learning and instructional technologies as visions of the future were discussed. Second, the importance of task analysis methods in rapid e-learning was considered, with learning technologies as asynchronous and synchronous e-learning development. Finally, rapid instructional design concepts and e-learning design strategies were defined and clarified with examples, that is, all steps for effective task analysis and rapid training development techniques based on learning and instructional design approaches were discussed, such as m-learning and other delivery systems. As a result, the concept of task analysis, rapid e-learning development strategies and the essentials of online course design were discussed, alongside learner interface design features for learners and designers.

  7. A simple and rapid PCR-based method to isolate complete small macronuclear minichromosomes from hypotrich ciliates: 5S rDNA and S26 ribosomal protein gene of Oxytricha (Sterkiella) nova.

    Science.gov (United States)

    Callejas, Sergio; Gutiérrez, Juan Carlos

    2002-06-01

    Hypotrich ciliates present a macronuclear genome consisting of gene-sized instead of chromosome-sized DNA molecules. Exploiting this unique eukaryotic genome feature, we introduce, for the first time in ciliates, a rapid and easy PCR method using telomeric primers to isolate small complete macronuclear DNA molecules or minichromosomes. Two presumably abundant macronuclear DNA molecules, containing ribosomal genes, were amplified from the Oxytricha (Sterkiella) nova complete genome after using this method, and then were cloned and sequenced. The 5S rDNA sequence of O. (S.) nova is the third one reported among hypotrich ciliates; its primary and secondary structure is compared with other eukaryotic 5S rRNAs. The ribosomal protein S26 gene is the first one reported among ciliates. This "End-End-PCR" method might be useful to obtain similar gene-sized macronuclear molecules from other hypotrich ciliates, and, therefore, to increase our knowledge on ribosomal genes in these eukaryotic microorganisms.

  8. The use of rapid review methods in health technology assessments: 3 case studies.

    Science.gov (United States)

    Kaltenthaler, Eva; Cooper, Katy; Pandor, Abdullah; Martyn-St James, Marrissa; Chatters, Robin; Wong, Ruth

    2016-08-26

    Rapid reviews are of increasing importance within health technology assessment due to time and resource constraints. There are many rapid review methods available although there is little guidance as to the most suitable methods. We present three case studies employing differing methods to suit the evidence base for each review and outline some issues to consider when selecting an appropriate method. Three recently completed systematic review short reports produced for the UK National Institute for Health Research were examined. Different approaches to rapid review methods were used in the three reports which were undertaken to inform the commissioning of services within the NHS and to inform future trial design. We describe the methods used, the reasoning behind the choice of methods and explore the strengths and weaknesses of each method. Rapid review methods were chosen to meet the needs of the review and each review had distinctly different challenges such as heterogeneity in terms of populations, interventions, comparators and outcome measures (PICO) and/or large numbers of relevant trials. All reviews included at least 10 randomised controlled trials (RCTs), each with numerous included outcomes. For the first case study (sexual health interventions), very diverse studies in terms of PICO were included. P-values and summary information only were presented due to substantial heterogeneity between studies and outcomes measured. For the second case study (premature ejaculation treatments), there were over 100 RCTs but also several existing systematic reviews. Data for meta-analyses were extracted directly from existing systematic reviews with new RCT data added where available. For the final case study (cannabis cessation therapies), studies included a wide range of interventions and considerable variation in study populations and outcomes. A brief summary of the key findings for each study was presented and narrative synthesis used to summarise results for each

  9. Bioluminescence-based system for rapid detection of natural transformation.

    Science.gov (United States)

    Santala, Ville; Karp, Matti; Santala, Suvi

    2016-07-01

    Horizontal gene transfer plays a significant role in bacterial evolution and has major clinical importance. Thus, it is vital to understand the mechanisms and kinetics of genetic transformations. Natural transformation is the driving mechanism for horizontal gene transfer in diverse genera of bacteria. Our study introduces a simple and rapid method for the investigation of natural transformation. This highly sensitive system allows the detection of a transformation event directly from a bacterial population without any separation step or selection of cells. The system is based on the bacterial luciferase operon from Photorhabdus luminescens The studied molecular tools consist of the functional modules luxCDE and luxAB, which involve a replicative plasmid and an integrative gene cassette. A well-established host for bacterial genetic investigations, Acinetobacter baylyi ADP1, is used as the model bacterium. We show that natural transformation followed by homologous recombination or plasmid recircularization can be readily detected in both actively growing and static biofilm-like cultures, including very rare transformation events. The system allows the detection of natural transformation within 1 h of introducing sample DNA into the culture. The introduced method provides a convenient means to study the kinetics of natural transformation under variable conditions and perturbations. © FEMS 2016. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  10. Rapid Methods for detection of Veterinary Drug residues in Meat

    Directory of Open Access Journals (Sweden)

    Chandan

    2010-10-01

    methodologies, the variety of residues to search per sample and the need to invest on powerful new instruments for identification and confirmatory purposes. Rapid and versatile screening methodologies make its control easier and reduce the number of non-compliant samples to be confirmed through tedious and costly confirmatory analytical methodologies. For instance, the multiresidue analysis can be performed better by using fast LC methods. Thus, the availability of new screening methodologies and the improvement of the existing ones will contribute to a better safety assurance of meat and other foods of animal origin. [Vet. World 2010; 3(5.000: 241-246

  11. Time evolution of the wave equation using rapid expansion method

    KAUST Repository

    Pestana, Reynam C.

    2010-07-01

    Forward modeling of seismic data and reverse time migration are based on the time evolution of wavefields. For the case of spatially varying velocity, we have worked on two approaches to evaluate the time evolution of seismic wavefields. An exact solution for the constant-velocity acoustic wave equation can be used to simulate the pressure response at any time. For a spatially varying velocity, a one-step method can be developed where no intermediate time responses are required. Using this approach, we have solved for the pressure response at intermediate times and have developed a recursive solution. The solution has a very high degree of accuracy and can be reduced to various finite-difference time-derivative methods, depending on the approximations used. Although the two approaches are closely related, each has advantages, depending on the problem being solved. © 2010 Society of Exploration Geophysicists.

  12. An evaluation of rapid methods for monitoring vegetation characteristics of wetland bird habitat

    Science.gov (United States)

    Tavernia, Brian G.; Lyons, James E.; Loges, Brian W.; Wilson, Andrew; Collazo, Jaime A.; Runge, Michael C.

    2016-01-01

    Wetland managers benefit from monitoring data of sufficient precision and accuracy to assess wildlife habitat conditions and to evaluate and learn from past management decisions. For large-scale monitoring programs focused on waterbirds (waterfowl, wading birds, secretive marsh birds, and shorebirds), precision and accuracy of habitat measurements must be balanced with fiscal and logistic constraints. We evaluated a set of protocols for rapid, visual estimates of key waterbird habitat characteristics made from the wetland perimeter against estimates from (1) plots sampled within wetlands, and (2) cover maps made from aerial photographs. Estimated percent cover of annuals and perennials using a perimeter-based protocol fell within 10 percent of plot-based estimates, and percent cover estimates for seven vegetation height classes were within 20 % of plot-based estimates. Perimeter-based estimates of total emergent vegetation cover did not differ significantly from cover map estimates. Post-hoc analyses revealed evidence for observer effects in estimates of annual and perennial covers and vegetation height. Median time required to complete perimeter-based methods was less than 7 percent of the time needed for intensive plot-based methods. Our results show that rapid, perimeter-based assessments, which increase sample size and efficiency, provide vegetation estimates comparable to more intensive methods.

  13. Melting Temperature Mapping Method: A Novel Method for Rapid Identification of Unknown Pathogenic Microorganisms within Three Hours of Sample Collection.

    Science.gov (United States)

    Niimi, Hideki; Ueno, Tomohiro; Hayashi, Shirou; Abe, Akihito; Tsurue, Takahiro; Mori, Masashi; Tabata, Homare; Minami, Hiroshi; Goto, Michihiko; Akiyama, Makoto; Yamamoto, Yoshihiro; Saito, Shigeru; Kitajima, Isao

    2015-07-28

    Acquiring the earliest possible identification of pathogenic microorganisms is critical for selecting the appropriate antimicrobial therapy in infected patients. We herein report the novel "melting temperature (Tm) mapping method" for rapidly identifying the dominant bacteria in a clinical sample from sterile sites. Employing only seven primer sets, more than 100 bacterial species can be identified. In particular, using the Difference Value, it is possible to identify samples suitable for Tm mapping identification. Moreover, this method can be used to rapidly diagnose the absence of bacteria in clinical samples. We tested the Tm mapping method using 200 whole blood samples obtained from patients with suspected sepsis, 85% (171/200) of which matched the culture results based on the detection level. A total of 130 samples were negative according to the Tm mapping method, 98% (128/130) of which were also negative based on the culture method. Meanwhile, 70 samples were positive according to the Tm mapping method, and of the 59 suitable for identification, 100% (59/59) exhibited a "match" or "broad match" with the culture or sequencing results. These findings were obtained within three hours of whole blood collection. The Tm mapping method is therefore useful for identifying infectious diseases requiring prompt treatment.

  14. Rapid method for identification of transgenic fish zygosity

    Directory of Open Access Journals (Sweden)

    . Alimuddin

    2007-07-01

    Full Text Available Identification of zygosity in transgenik fish is normally achieved by PCR analysis with genomic DNA template extracted from the tissue of progenies which are derived by mating the transgenic fish and wild-type counterpart.  This method needs relatively large amounts of fish material and is time- and labor-intensive. New approaches addressing this problem could be of great help for fish biotechnologists.  In this experiment, we applied a quantitative real-time PCR (qr-PCR method to analyze zygosity in a stable line of transgenic zebrafish (Danio rerio carrying masu salmon, Oncorhynchus masou D6-desaturase-like gene. The qr-PCR was performed using iQ SYBR Green Supermix in the iCycler iQ Real-time PCR Detection System (Bio-Rad Laboratories, USA.  Data were analyzed using the comparative cycle threshold method.  The results demonstrated a clear-cut identification of all transgenic fish (n=20 classified as a homozygous or heterozygous.  Mating of those fish with wild-type had revealed transgene transmission to the offspring following expected Mendelian laws. Thus, we found that the qTR-PCR to be effective for a rapid and precise determination of zygosity in transgenic fish. This technique could be useful in the establishment of breeding programs for mass transgenic fish production and in experiments in which zygosity effect could have a functional impact. Keywords: quantitative real-time PCR; zygosity; transgenic fish; mass production   ABSTRAK Identifikasi sigositas ikan transgenik biasanya dilakukan menggunakan analisa PCR dengan cetakan DNA genomik yang diekstraksi dari jaringan ikan hasil persilangan antara ikan transgenik dan ikan normal.   Metode ini memerlukan ikan dalam jumlah yang banyak, dan juga waktu serta tenaga.  Pendekatan baru untuk mengatasi masalah tersebut akan memberikan manfaat besar kepada peneliti bioteknologi perikanan.  Pada penelitian ini, kami menggunakan metode PCR real-time kuantitatif (krt-PCR untuk

  15. A rapid cloning method employing orthogonal end protection

    NARCIS (Netherlands)

    Jakobi, A.J.|info:eu-repo/dai/nl/311489621; Huizinga, E.G.|info:eu-repo/dai/nl/12314969X

    2012-01-01

    We describe a novel in vitro cloning strategy that combines standard tools in molecular biology with a basic protecting group concept to create a versatile framework for the rapid and seamless assembly of modular DNA building blocks into functional open reading frames. Analogous to chemical

  16. Mycobacteria mobility shift assay: a method for the rapid identification of Mycobacterium tuberculosis and nontuberculous mycobacteria

    Directory of Open Access Journals (Sweden)

    Letícia Muraro Wildner

    2014-06-01

    Full Text Available The identification of mycobacteria is essential because tuberculosis (TB and mycobacteriosis are clinically indistinguishable and require different therapeutic regimens. The traditional phenotypic method is time consuming and may last up to 60 days. Indeed, rapid, affordable, specific and easy-to-perform identification methods are needed. We have previously described a polymerase chain reaction-based method called a mycobacteria mobility shift assay (MMSA that was designed for Mycobacterium tuberculosis complex (MTC and nontuberculous mycobacteria (NTM species identification. The aim of this study was to assess the MMSA for the identification of MTC and NTM clinical isolates and to compare its performance with that of the PRA-hsp65 method. A total of 204 clinical isolates (102 NTM and 102 MTC were identified by the MMSA and PRA-hsp65. For isolates for which these methods gave discordant results, definitive species identification was obtained by sequencing fragments of the 16S rRNA and hsp65 genes. Both methods correctly identified all MTC isolates. Among the NTM isolates, the MMSA alone assigned 94 (92.2% to a complex or species, whereas the PRA-hsp65 method assigned 100% to a species. A 91.5% agreement was observed for the 94 NTM isolates identified by both methods. The MMSA provided correct identification for 96.8% of the NTM isolates compared with 94.7% for PRA-hsp65. The MMSA is a suitable auxiliary method for routine use for the rapid identification of mycobacteria.

  17. Mycobacteria mobility shift assay: a method for the rapid identification of Mycobacterium tuberculosis and nontuberculous mycobacteria.

    Science.gov (United States)

    Wildner, Letícia Muraro; Bazzo, Maria Luiza; Liedke, Susie Coutinho; Nogueira, Christiane Lourenço; Segat, Gabriela; Senna, Simone Gonçalves; Schlindwein, Aline Daiane; Oliveira, Jaquelline Germano de; Rovaris, Darcita B; Bonjardim, Claudio A; Kroon, Erna G; Ferreira, Paulo C P

    2014-06-01

    The identification of mycobacteria is essential because tuberculosis (TB) and mycobacteriosis are clinically indistinguishable and require different therapeutic regimens. The traditional phenotypic method is time consuming and may last up to 60 days. Indeed, rapid, affordable, specific and easy-to-perform identification methods are needed. We have previously described a polymerase chain reaction-based method called a mycobacteria mobility shift assay (MMSA) that was designed for Mycobacterium tuberculosis complex (MTC) and nontuberculous mycobacteria (NTM) species identification. The aim of this study was to assess the MMSA for the identification of MTC and NTM clinical isolates and to compare its performance with that of the PRA-hsp65 method. A total of 204 clinical isolates (102 NTM and 102 MTC) were identified by the MMSA and PRA-hsp65. For isolates for which these methods gave discordant results, definitive species identification was obtained by sequencing fragments of the 16S rRNA and hsp65 genes. Both methods correctly identified all MTC isolates. Among the NTM isolates, the MMSA alone assigned 94 (92.2%) to a complex or species, whereas the PRA-hsp65 method assigned 100% to a species. A 91.5% agreement was observed for the 94 NTM isolates identified by both methods. The MMSA provided correct identification for 96.8% of the NTM isolates compared with 94.7% for PRA-hsp65. The MMSA is a suitable auxiliary method for routine use for the rapid identification of mycobacteria.

  18. A rapid method for soil cement design : Louisiana slope value method.

    Science.gov (United States)

    1964-03-01

    The current procedure used by the Louisiana Department of Highways for laboratory design of cement stabilized soil base and subbase courses is taken from standard AASHO test methods, patterned after Portland Cement Association criteria. These methods...

  19. Rapid Radiochemical Method for Americium-241 in Building ...

    Science.gov (United States)

    Technical Fact Sheet Analysis Purpose: Qualitative analysis Technique: Alpha spectrometry Method Developed for: Americium-241 in building materials Method Selected for: SAM lists this method for qualitative analysis of americium-241 in concrete or brick building materials. Summary of subject analytical method which will be posted to the SAM website to allow access to the method.

  20. Rapid Radiochemical Method for Radium-226 in Building ...

    Science.gov (United States)

    Technical Fact Sheet Analysis Purpose: Qualitative analysis Technique: Alpha spectrometry Method Developed for: Radium-226 in building materials Method Selected for: SAM lists this method for qualitative analysis of radium-226 in concrete or brick building materials Summary of subject analytical method which will be posted to the SAM website to allow access to the method.

  1. Visual and colorimetric methods for rapid determination of total tannins in vegetable raw materials

    Directory of Open Access Journals (Sweden)

    S. P. Kalinkina

    2016-01-01

    Full Text Available The article is dedicated to the development of rapid colorimetric method for determining the amount of tannins in aqueous extracts of vegetable raw materials. The sorption-based colorimetric test is determining sorption tannins polyurethane foam, impregnated of FeCl3, receiving on its surface painted in black and green color of the reaction products and the determination of their in sorbent matrix. Selectivity is achieved by determining the tannins specific interaction of polyphenols with iron ions (III. The conditions of sorption-colorimetric method: the concentration of ferric chloride (III, impregnated in the polyurethane foam; sorbent mass in the analytical cartridge; degree of loading his agent; the contact time of the phases. color scales have been developed for the visual determination of the amount of tannins in terms of gallic acid. Spend a digitized image obtained scales using computer program “Sorbfil TLC”, excluding a subjective assessment of the intensity of the color scale of the test. The results obtained determine the amount of tannins in aqueous extracts of vegetable raw rapid method using tablets and analytical cartridges. The results of the test determination of tannins with visual and densitometric analytical signal registration are compared to known methods. Spend a metrological evaluation of the results of determining the amount of tannins sorption rapid colorimetric methods. Time visual and densitometric rapid determination of tannins, taking into account the sample preparation is 25–30 minutes, the relative error does not exceed 28 %. The developed test methods for quantifying the content of tannins allow to exclude the use of sophisticated analytical equipment, carry out the analysis in non-laboratory conditions do not require highly skilled personnel.

  2. Development of a loop-mediated isothermal amplification method for rapid detection of pigeon circovirus.

    Science.gov (United States)

    Tsai, Shinn Shyong; Chang, Yeng Ling; Huang, Yen Li; Liu, Hung Jen; Ke, Guan Ming; Chiou, Chwei Jang; Hsieh, Yao Ching; Chang, Tsung Chou; Cheng, Li Ting; Chuang, Kuo Pin

    2014-05-01

    There are no effective antiviral treatments for pigeon circovirus (PiCV); thus, rapid diagnosis is critical for effective control of the disease caused by this virus. The recent development of a novel LAMP technique that amplifies nucleic acids rapidly with high specificity and sensitivity under isothermal conditions has overcome some of the deficiencies of nucleic-acid-based diagnostic tests. We established a LAMP method for rapid detection of PiCV using two pairs of primers that were designed from PiCV and compared its sensitivity and specificity with that of PCR. Amplification by LAMP was optimal at 63 °C for 60 min. The detection limit was nearly 0.5 pg of PiCV DNA, making it ten times more sensitive than PCR. There was no cross-reaction with porcine circovirus type 2 (PCV2), pigeon Trichomonas gallinae, or pigeon herpesvirus (PHV) under the same conditions. The assay also successfully detected the pathogen DNA in the tissues of infected pigeons. This is the first report indicating that LAMP is a valuable, rapid method of detecting PiCV with high sensitivity and specificity.

  3. Rapid method for plutonium-241 determination in soil samples

    OpenAIRE

    Piekarz, M.; Komosa, A.

    2014-01-01

    A simple and rapid procedure for the determination of plutonium isotopes in the environment is presented. The procedure combines alpha spectrometry, solvent extraction and liquid scintillation measurements to ensure that both alpha- and beta-emitting isotopes are determined. Of five tested extractants, bis-(2-ethylhexyl) phosphoric acid was found to be the best choice. The procedure was applied to soil samples contaminated with Chernobyl fallout.

  4. A low complexity rapid molecular method for detection of Clostridium difficile in stool.

    Directory of Open Access Journals (Sweden)

    Cathal J McElgunn

    Full Text Available Here we describe a method for the detection of Clostridium difficile from stool using a novel low-complexity and rapid extraction process called Heat Elution (HE. The HE method is two-step and takes just 10 minutes, no specialist instruments are required and there is minimal hands-on time. A test method using HE was developed in conjunction with Loop-mediated Isothermal Amplification (LAMP combined with the real-time bioluminescent reporter system known as BART targeting the toxin B gene (tcdB. The HE-LAMP-BART method was evaluated in a pilot study on clinical fecal samples (tcdB(+, n = 111; tcdB(-, n= 107. The HE-LAMP-BART method showed 95.5% sensitivity and 100% specificity against a gold standard reference method using cytotoxigenic culture and also a silica-based robotic extraction followed by tcdB PCR to control for storage. From sample to result, the HE-LAMP-BART method typically took 50 minutes, whereas the PCR method took >2.5 hours. In a further study (tcdB(+, n = 47; tcdB(-, n= 28 HE-LAMP-BART was compared to an alternative commercially available LAMP-based method, Illumigene (Meridian Bioscience, OH, and yielded 87.2% sensitivity and 100% specificity for the HE-LAMP-BART method compared to 76.6% and 100%, respectively, for Illumigene against the reference method. A subset of 27 samples (tcdB(+, n = 25; tcdB(-, n= 2 were further compared between HE-LAMP-BART, Illumigene, GeneXpert (Cepheid, Sunnyvale, CA and RIDA®QUICK C. difficile Toxin A/B lateral flow rapid test (R-Biopharm, Darmstadt, Germany resulting in sensitivities of HE-LAMP-BART 92%, Illumigene 72% GeneXpert 96% and RIDAQuick 76% against the reference method. The HE-LAMP-BART method offers the advantages of molecular based approaches without the cost and complexity usually associated with molecular tests. Further, the rapid time-to-result and simple protocol means the method can be applied away from the centralized laboratory settings.

  5. Rapid and Green Analytical Method for the Determination of Quinoline Alkaloids from Cinchona succirubra Based on Microwave-Integrated Extraction and Leaching (MIEL) Prior to High Performance Liquid Chromatography

    Science.gov (United States)

    Fabiano-Tixier, Anne-Sylvie; Elomri, Abdelhakim; Blanckaert, Axelle; Seguin, Elisabeth; Petitcolas, Emmanuel; Chemat, Farid

    2011-01-01

    Quinas contains several compounds, such as quinoline alkaloids, principally quinine, quinidine, cinchonine and cichonidine. Identified from barks of Cinchona, quinine is still commonly used to treat human malaria. Microwave-Integrated Extraction and Leaching (MIEL) is proposed for the extraction of quinoline alkaloids from bark of Cinchona succirubra. The process is performed in four steps, which ensures complete, rapid and accurate extraction of the samples. Optimal conditions for extraction were obtained using a response surface methodology reached from a central composite design. The MIEL extraction has been compared with a conventional technique soxhlet extraction. The extracts of quinoline alkaloids from C. succirubra obtained by these two different methods were compared by HPLC. The extracts obtained by MIEL in 32 min were quantitatively (yield) and qualitatively (quinine, quinidine, cinchonine, cinchonidine) similar to those obtained by conventional Soxhlet extraction in 3 hours. MIEL is a green technology that serves as a good alternative for the extraction of Cinchona alkaloids. PMID:22174637

  6. Interactive Rapid Dose Assessment Model (IRDAM): reactor-accident assessment methods. Vol. 2

    Energy Technology Data Exchange (ETDEWEB)

    Poeton, R.W.; Moeller, M.P.; Laughlin, G.J.; Desrosiers, A.E.

    1983-05-01

    As part of the continuing emphasis on emergency preparedness, the US Nuclear Regulatory Commission (NRC) sponsored the development of a rapid dose assessment system by Pacific Northwest Laboratory (PNL). This system, the Interactive Rapid Dose Assessment Model (IRDAM) is a micro-computer based program for rapidly assessing the radiological impact of accidents at nuclear power plants. This document describes the technical bases for IRDAM including methods, models and assumptions used in calculations. IRDAM calculates whole body (5-cm depth) and infant thyroid doses at six fixed downwind distances between 500 and 20,000 meters. Radionuclides considered primarily consist of noble gases and radioiodines. In order to provide a rapid assessment capability consistent with the capacity of the Osborne-1 computer, certain simplifying approximations and assumptions are made. These are described, along with default values (assumptions used in the absence of specific input) in the text of this document. Two companion volumes to this one provide additional information on IRDAM. The user's Guide (NUREG/CR-3012, Volume 1) describes the setup and operation of equipment necessary to run IRDAM. Scenarios for Comparing Dose Assessment Models (NUREG/CR-3012, Volume 3) provides the results of calculations made by IRDAM and other models for specific accident scenarios.

  7. A Rapid and Economical Method for Efficient DNA Extraction from Diverse Soils Suitable for Metagenomic Applications.

    Directory of Open Access Journals (Sweden)

    Selvaraju Gayathri Devi

    Full Text Available A rapid, cost effective method of metagenomic DNA extraction from soil is a useful tool for environmental microbiology. The present work describes an improved method of DNA extraction namely "powdered glass method" from diverse soils. The method involves the use of sterile glass powder for cell lysis followed by addition of 1% powdered activated charcoal (PAC as purifying agent to remove humic substances. The method yielded substantial DNA (5.87 ± 0.04 μg/g of soil with high purity (A260/280: 1.76 ± 0.05 and reduced humic substances (A340: 0.047 ± 0.03. The quality of the extracted DNA was compared against five different methods based on 16S rDNA PCR amplification, BamHI digestion and validated using quantitative PCR. The digested DNA was used for a metagenomic library construction with the transformation efficiency of 4 X 106 CFU mL-1. Besides providing rapid, efficient and economical extraction of metgenomic DNA from diverse soils, this method's applicability is also demonstrated for cultivated organisms (Gram positive B. subtilis NRRL-B-201, Gram negative E. coli MTCC40, and a microalgae C. sorokiniana UTEX#1666.

  8. A Rapid and Economical Method for Efficient DNA Extraction from Diverse Soils Suitable for Metagenomic Applications.

    Science.gov (United States)

    Devi, Selvaraju Gayathri; Fathima, Anwar Aliya; Radha, Sudhakar; Arunraj, Rex; Curtis, Wayne R; Ramya, Mohandass

    2015-01-01

    A rapid, cost effective method of metagenomic DNA extraction from soil is a useful tool for environmental microbiology. The present work describes an improved method of DNA extraction namely "powdered glass method" from diverse soils. The method involves the use of sterile glass powder for cell lysis followed by addition of 1% powdered activated charcoal (PAC) as purifying agent to remove humic substances. The method yielded substantial DNA (5.87 ± 0.04 μg/g of soil) with high purity (A260/280: 1.76 ± 0.05) and reduced humic substances (A340: 0.047 ± 0.03). The quality of the extracted DNA was compared against five different methods based on 16S rDNA PCR amplification, BamHI digestion and validated using quantitative PCR. The digested DNA was used for a metagenomic library construction with the transformation efficiency of 4 X 106 CFU mL-1. Besides providing rapid, efficient and economical extraction of metgenomic DNA from diverse soils, this method's applicability is also demonstrated for cultivated organisms (Gram positive B. subtilis NRRL-B-201, Gram negative E. coli MTCC40, and a microalgae C. sorokiniana UTEX#1666).

  9. Rapid Prototyping of Field Programmable Gate Array-Based Discrete Cosine Transform Approximations

    Directory of Open Access Journals (Sweden)

    Trevor W. Fox

    2003-05-01

    Full Text Available A method for the rapid design of field programmable gate array (FPGA-based discrete cosine transform (DCT approximations is presented that can be used to control the coding gain, mean square error (MSE, quantization noise, hardware cost, and power consumption by optimizing the coefficient values and datapath wordlengths. Previous DCT design methods can only control the quality of the DCT approximation and estimates of the hardware cost by optimizing the coefficient values. It is shown that it is possible to rapidly prototype FPGA-based DCT approximations with near optimal coding gains that satisfy the MSE, hardware cost, quantization noise, and power consumption specifications.

  10. Multifrequency excitation method for rapid and accurate dynamic test of micromachined gyroscope chips.

    Science.gov (United States)

    Deng, Yan; Zhou, Bin; Xing, Chao; Zhang, Rong

    2014-10-17

    A novel multifrequency excitation (MFE) method is proposed to realize rapid and accurate dynamic testing of micromachined gyroscope chips. Compared with the traditional sweep-frequency excitation (SFE) method, the computational time for testing one chip under four modes at a 1-Hz frequency resolution and 600-Hz bandwidth was dramatically reduced from 10 min to 6 s. A multifrequency signal with an equal amplitude and initial linear-phase-difference distribution was generated to ensure test repeatability and accuracy. The current test system based on LabVIEW using the SFE method was modified to use the MFE method without any hardware changes. The experimental results verified that the MFE method can be an ideal solution for large-scale dynamic testing of gyroscope chips and gyroscopes.

  11. Multifrequency Excitation Method for Rapid and Accurate Dynamic Test of Micromachined Gyroscope Chips

    Directory of Open Access Journals (Sweden)

    Yan Deng

    2014-10-01

    Full Text Available A novel multifrequency excitation (MFE method is proposed to realize rapid and accurate dynamic testing of micromachined gyroscope chips. Compared with the traditional sweep-frequency excitation (SFE method, the computational time for testing one chip under four modes at a 1-Hz frequency resolution and 600-Hz bandwidth was dramatically reduced from 10 min to 6 s. A multifrequency signal with an equal amplitude and initial linear-phase-difference distribution was generated to ensure test repeatability and accuracy. The current test system based on LabVIEW using the SFE method was modified to use the MFE method without any hardware changes. The experimental results verified that the MFE method can be an ideal solution for large-scale dynamic testing of gyroscope chips and gyroscopes.

  12. A rapid, small-scale sedimentation method to predict breadmaking quality of hard winter wheat

    Science.gov (United States)

    Breeders and processors are always looking for rapid and accurate methods to evaluate wheat quality. A rapid small-scale hybrid sedimentation method was developed for predicting breadmaking quality of breeders samples by combining the sodium dodecyl-sulfate (SDS) sedimentation method (AACC 56-70) an...

  13. A rapid method to estimate Westergren sedimentation rates

    Science.gov (United States)

    Alexy, Tamas; Pais, Eszter; Meiselman, Herbert J.

    2009-01-01

    The erythrocyte sedimentation rate (ESR) is a nonspecific but simple and inexpensive test that was introduced into medical practice in 1897. Although it is commonly utilized in the diagnosis and follow-up of various clinical conditions, ESR has several limitations including the required 60 min settling time for the test. Herein we introduce a novel use for a commercially available computerized tube viscometer that allows the accurate prediction of human Westergren ESR rates in as little as 4 min. Owing to an initial pressure gradient, blood moves between two vertical tubes through a horizontal small-bore tube and the top of the red blood cell (RBC) column in each vertical tube is monitored continuously with an accuracy of 0.083 mm. Using data from the final minute of a blood viscosity measurement, a sedimentation index (SI) was calculated and correlated with results from the conventional Westergren ESR test. To date, samples from 119 human subjects have been studied and our results indicate a strong correlation between SI and ESR values (R2=0.92). In addition, we found a close association between SI and RBC aggregation indices as determined by an automated RBC aggregometer (R2=0.71). Determining SI on human blood is rapid, requires no special training and has minimal biohazard risk, thus allowing physicians to rapidly screen for individuals with elevated ESR and to monitor therapeutic responses. PMID:19791973

  14. A direct and rapid method to determine cyanide in urine by capillary electrophoresis.

    Science.gov (United States)

    Zhang, Qiyang; Maddukuri, Naveen; Gong, Maojun

    2015-10-02

    Cyanides are poisonous chemicals that widely exist in nature and industrial processes as well as accidental fires. Rapid and accurate determination of cyanide exposure would facilitate forensic investigation, medical diagnosis, and chronic cyanide monitoring. Here, a rapid and direct method was developed for the determination of cyanide ions in urinary samples. This technique was based on an integrated capillary electrophoresis system coupled with laser-induced fluorescence (LIF) detection. Cyanide ions were derivatized with naphthalene-2,3-dicarboxaldehyde (NDA) and a primary amine (glycine) for LIF detection. Three separate reagents, NDA, glycine, and cyanide sample, were mixed online, which secured uniform conditions between samples for cyanide derivatization and reduced the risk of precipitation formation of mixtures. Conditions were optimized; the derivatization was completed in 2-4min, and the separation was observed in 25s. The limit of detection (LOD) was 4.0nM at 3-fold signal-to-noise ratio for standard cyanide in buffer. The cyanide levels in urine samples from smokers and non-smokers were determined by using the method of standard addition, which demonstrated significant difference of cyanide levels in urinary samples from the two groups of people. The developed method was rapid and accurate, and is anticipated to be applicable to cyanide detection in waste water with appropriate modification. Published by Elsevier B.V.

  15. A rapid, accurate and sensitive method with the new stable isotopic tags based on microwave-assisted dispersive liquid-liquid microextraction and its application to the determination of hydroxyl UV filters in environmental water samples.

    Science.gov (United States)

    Li, Xiu; Chen, Guang; Liu, Jianjun; Liu, Yuxia; Zhao, Xianen; Cao, Ziping; Xia, Lian; Li, Guoliang; Sun, Zhiwei; Zhang, Shijuan; Wang, Hua; You, Jinmao

    2017-05-15

    A rapid, accurate and sensitive method, using the stable isotope labeling (SIL), microwave-assisted dispersive liquid-liquid micro extraction (MADLLME) and the ultra-high performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS), was developed and validated for the determination of hydroxyl UV Filters in environmental water samples. A pair of new isotopic tags D0-/D3-1-methylindole-3-acetic acid (D0-/D3-MIAA) is synthesized, with which a simple yet efficient pretreatment MADLLME-SIL is developed. Under the optimized conditions (80℃, 240W, 180s), the sample pretreatment including analyte extraction, pre-concentration and isotope labeling can be finished conveniently in only 9min. D0-/D3-MIAA labeling improves the chromatographic retention by strengthening the hydrophobicity and enhances the MS response for 3-4 orders of magnitude. Excellent linearity is established by the H/D ratios of 1/10-10/1 with the correlation coefficients >0.9990. The quite low detection limits (0.54-1.79ng/L) are achieved, ensuring the trace detection. This method is successfully applied to a series of environmental water samples. The recoveries (93.2%~103.5%) are significantly improved and the analysis time is largely reduced (filters in water samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Comparison of rapid colorimetric method with conventional method in the isolation of mycobacterium tuberculosis

    Directory of Open Access Journals (Sweden)

    Oberoi A

    2004-01-01

    Full Text Available The aim of the study was to evaluate two methods (colorimetric and conventional for isolation of Mycobacterium tuberculosis. A total of 500 clinical specimens were processed by modified Petroff′s method and then inoculated into MB/BacT-240 system bottles and on LJ medium slopes. The specimens included 242 sputum, 95 gastric aspirates, 47 pleural fluids, 45 CSF, 32 urine, 18 pus, 11 bronchoalveolar lavage, 3 tissue, 2 stool, 2 lymphnode specimens, 2 synovial fluid and 1 bronchial wash specimens. The isolation rate was 16.4% by the colorimetric method and 2.2% by the conventional method. The mean detection time was 16 days and 26 days respectively. Among 36 direct smear positive samples, 63.9%(23/36 and 30%(11/36 were positive by colorimetric and conventional methods respectively. Out of 464 direct smear negative samples 12.9%(60/464 and 0.6%(3/464 were positive by colorimetric and conventional methods respectively. Therefore, colorimetric method enables rapid detection leading to early diagnosis and drug susceptibility testing.

  17. Rapid and Reliable HPLC Method for the Determination of Vitamin ...

    African Journals Online (AJOL)

    Purpose: To develop and validate an accurate, sensitive and reproducible high performance liquid chromatographic (HPLC) method for the quantitation of vitamin C in pharmaceutical samples. Method: The drug and the standard were eluted from Superspher RP-18 (250 mm x 4.6 mm, 10ìm particle size) at 20 0C.

  18. Rapid, cost-effective liquid chromatograghic method for the ...

    African Journals Online (AJOL)

    The method is highly sensitive, with limit of detection of 1 ng/ml. The coefficient of variation for within-day run was less than 4% while that of day-to-day run was less than 6%. There were no interfering peaks from endogenous materials in the serum. The method was validated and used for pharmacokinetic studies ...

  19. A rapid method for counting nucleated erythrocytes on stained blood smears by digital image analysis

    Science.gov (United States)

    Gering, E.; Atkinson, C.T.

    2004-01-01

    Measures of parasitemia by intraerythrocytic hematozoan parasites are normally expressed as the number of infected erythrocytes per n erythrocytes and are notoriously tedious and time consuming to measure. We describe a protocol for generating rapid counts of nucleated erythrocytes from digital micrographs of thin blood smears that can be used to estimate intensity of hematozoan infections in nonmammalian vertebrate hosts. This method takes advantage of the bold contrast and relatively uniform size and morphology of erythrocyte nuclei on Giemsa-stained blood smears and uses ImageJ, a java-based image analysis program developed at the U.S. National Institutes of Health and available on the internet, to recognize and count these nuclei. This technique makes feasible rapid and accurate counts of total erythrocytes in large numbers of microscope fields, which can be used in the calculation of peripheral parasitemias in low-intensity infections.

  20. Logic Foundry: Rapid Prototyping for FPGA-Based DSP Systems

    Directory of Open Access Journals (Sweden)

    Bhattacharyya Shuvra S

    2003-01-01

    Full Text Available We introduce the Logic Foundry, a system for the rapid creation and integration of FPGA-based digital signal processing systems. Recognizing that some of the greatest challenges in creating FPGA-based systems occur in the integration of the various components, we have proposed a system that targets the following four areas of integration: design flow integration, component integration, platform integration, and software integration. Using the Logic Foundry, a system can be easily specified, and then automatically constructed and integrated with system level software.

  1. Comparison of concentration methods for rapid detection of hookworm ova in wastewater matrices using quantitative PCR.

    Science.gov (United States)

    Gyawali, P; Ahmed, W; Jagals, P; Sidhu, J P S; Toze, S

    2015-12-01

    Hookworm infection contributes around 700 million infections worldwide especially in developing nations due to increased use of wastewater for crop production. The effective recovery of hookworm ova from wastewater matrices is difficult due to their low concentrations and heterogeneous distribution. In this study, we compared the recovery rates of (i) four rapid hookworm ova concentration methods from municipal wastewater, and (ii) two concentration methods from sludge samples. Ancylostoma caninum ova were used as surrogate for human hookworm (Ancylostoma duodenale and Necator americanus). Known concentration of A. caninum hookworm ova were seeded into wastewater (treated and raw) and sludge samples collected from two wastewater treatment plants (WWTPs) in Brisbane and Perth, Australia. The A. caninum ova were concentrated from treated and raw wastewater samples using centrifugation (Method A), hollow fiber ultrafiltration (HFUF) (Method B), filtration (Method C) and flotation (Method D) methods. For sludge samples, flotation (Method E) and direct DNA extraction (Method F) methods were used. Among the four methods tested, filtration (Method C) method was able to recover higher concentrations of A. caninum ova consistently from treated wastewater (39-50%) and raw wastewater (7.1-12%) samples collected from both WWTPs. The remaining methods (Methods A, B and D) yielded variable recovery rate ranging from 0.2 to 40% for treated and raw wastewater samples. The recovery rates for sludge samples were poor (0.02-4.7), although, Method F (direct DNA extraction) provided 1-2 orders of magnitude higher recovery rate than Method E (flotation). Based on our results it can be concluded that the recovery rates of hookworm ova from wastewater matrices, especially sludge samples, can be poor and highly variable. Therefore, choice of concentration method is vital for the sensitive detection of hookworm ova in wastewater matrices. Crown Copyright © 2015. Published by Elsevier

  2. Novel water-based antiseptic lotion demonstrates rapid, broad-spectrum kill compared with alcohol antiseptic.

    Science.gov (United States)

    Czerwinski, Steven E; Cozean, Jesse; Cozean, Colette

    2014-01-01

    A novel alcohol-based antiseptic and a novel water-based antiseptic lotion, both with a synergistic combination of antimicrobial ingredients containing 0.2% benzethonium chloride, were evaluated using the standard time-kill method against 25 FDA-specified challenge microorganisms. The purpose of the testing was to determine whether a non-alcohol product could have equivalent rapid and broad-spectrum kill to a traditional alcohol sanitizer. Both the alcohol- and water-based products showed rapid and broad-spectrum antimicrobial activity. The average 15-s kill was 99.999% of the challenge organism for the alcohol-based antiseptic and 99.971% for the water-based antiseptic. The alcohol-based product demonstrated 100% of peak efficacy (60s) within the first 15s, whereas the water-based product showed 99.97%. The novel alcohol-based antiseptic reduced concentrations of 100% of organisms by 99.999%, whereas the water-based antiseptic lotion showed the same reduction for 96% of organisms. A novel water-based antiseptic product demonstrated equivalent rapid, broad-spectrum antimicrobial activity to an alcohol-based sanitizer and provided additional benefits of reduced irritation, persistent effect, and greater efficacy against common viruses. The combination of rapid, broad-spectrum immediate kill and persistent efficacy against pathogens may have significant clinical benefit in limiting the spread of disease. Copyright © 2014 King Saud Bin Abdulaziz University for Health Sciences. Published by Elsevier Ltd. All rights reserved.

  3. A rapid method for soil cement design : Louisiana slope value method : part II : evaluation.

    Science.gov (United States)

    1966-05-01

    This report is an evaluation of the recently developed "Louisiana Slope Value Method". : The conclusion drawn are based on data from 637 separate samples representing nearly all major soil groups in Louisiana that are suitable for cement stabilizatio...

  4. A novel rapid and reproducible flow cytometric method for optimization of transfection efficiency in cells

    Science.gov (United States)

    Homann, Stefanie; Hofmann, Christian; Gorin, Aleksandr M.; Nguyen, Huy Cong Xuan; Huynh, Diana; Hamid, Phillip; Maithel, Neil; Yacoubian, Vahe; Mu, Wenli; Kossyvakis, Athanasios; Sen Roy, Shubhendu; Yang, Otto Orlean

    2017-01-01

    Transfection is one of the most frequently used techniques in molecular biology that is also applicable for gene therapy studies in humans. One of the biggest challenges to investigate the protein function and interaction in gene therapy studies is to have reliable monospecific detection reagents, particularly antibodies, for all human gene products. Thus, a reliable method that can optimize transfection efficiency based on not only expression of the target protein of interest but also the uptake of the nucleic acid plasmid, can be an important tool in molecular biology. Here, we present a simple, rapid and robust flow cytometric method that can be used as a tool to optimize transfection efficiency at the single cell level while overcoming limitations of prior established methods that quantify transfection efficiency. By using optimized ratios of transfection reagent and a nucleic acid (DNA or RNA) vector directly labeled with a fluorochrome, this method can be used as a tool to simultaneously quantify cellular toxicity of different transfection reagents, the amount of nucleic acid plasmid that cells have taken up during transfection as well as the amount of the encoded expressed protein. Finally, we demonstrate that this method is reproducible, can be standardized and can reliably and rapidly quantify transfection efficiency, reducing assay costs and increasing throughput while increasing data robustness. PMID:28863132

  5. A Rapid and Economical Method for Efficient DNA Extraction from Diverse Soils Suitable for Metagenomic Applications

    Science.gov (United States)

    Devi, Selvaraju Gayathri; Fathima, Anwar Aliya; Radha, Sudhakar; Arunraj, Rex; Curtis, Wayne R.; Ramya, Mohandass

    2015-01-01

    A rapid, cost effective method of metagenomic DNA extraction from soil is a useful tool for environmental microbiology. The present work describes an improved method of DNA extraction namely “powdered glass method” from diverse soils. The method involves the use of sterile glass powder for cell lysis followed by addition of 1% powdered activated charcoal (PAC) as purifying agent to remove humic substances. The method yielded substantial DNA (5.87 ± 0.04 μg/g of soil) with high purity (A260/280: 1.76 ± 0.05) and reduced humic substances (A340: 0.047 ± 0.03). The quality of the extracted DNA was compared against five different methods based on 16S rDNA PCR amplification, BamHI digestion and validated using quantitative PCR. The digested DNA was used for a metagenomic library construction with the transformation efficiency of 4 X 106 CFU mL-1. Besides providing rapid, efficient and economical extraction of metgenomic DNA from diverse soils, this method’s applicability is also demonstrated for cultivated organisms (Gram positive B. subtilis NRRL-B-201, Gram negative E. coli MTCC40, and a microalgae C. sorokiniana UTEX#1666). PMID:26167854

  6. A rapid cloning method employing orthogonal end protection.

    Directory of Open Access Journals (Sweden)

    Arjen J Jakobi

    Full Text Available We describe a novel in vitro cloning strategy that combines standard tools in molecular biology with a basic protecting group concept to create a versatile framework for the rapid and seamless assembly of modular DNA building blocks into functional open reading frames. Analogous to chemical synthesis strategies, our assembly design yields idempotent composite synthons amenable to iterative and recursive split-and-pool reaction cycles. As an example, we illustrate the simplicity, versatility and efficiency of the approach by constructing an open reading frame composed of tandem arrays of a human fibronectin type III (FNIII domain and the von Willebrand Factor A2 domain (VWFA2, as well as chimeric (FNIII(n-VWFA2-(FNIII(n constructs. Although we primarily designed this strategy to accelerate assembly of repetitive constructs for single-molecule force spectroscopy, we anticipate that this approach is equally applicable to the reconstitution and modification of complex modular sequences including structural and functional analysis of multi-domain proteins, synthetic biology or the modular construction of episomal vectors.

  7. Rapid, specific and sensitive method for isoniazid determination in serum.

    Science.gov (United States)

    Sadeg, N; Pertat, N; Dutertre, H; Dumontet, M

    1996-01-12

    An original simple, specific and rapid high-performance liquid chromatographic assay for the determination of isoniazid (INH) in human serum is presented. The drug was extracted from the serum by protein precipitation with 30% (w/v) trichloroacetic acid, then the drug was reacted with the coupling reagent, trans-cinnamaldehyde, to form a derivative absorbing at 340 nm. A 20-microliters aliquot was injected into the chromatograph after neutralization with 1 M KOH solution. A liquid chromatograph equipped with a reversed-phase 30-microns C18 precolumn linked to a 4-microns C18 analytical column was used. The drug was eluted with a mixture of acetonitrile-water-triethylamine-acetic acid (400:600:2:1, v/v), pH value was 5 +/- 1. Flow-rate and wavelength were set at 1 ml/min and 340 nm, respectively. The extraction recoveries from human serum averaged 100% for INH at concentrations of 1, 2 and 4 mg/l. The coefficients of variation for three different concentrations for INH in serum in the within-day study varied between 1.2 and 3.5%, whereas those in the day-to-day study varied between 2.8 and 4.3%.

  8. Asymptotic and Numerical Methods for Rapidly Rotating Buoyant Flow

    Science.gov (United States)

    Grooms, Ian G.

    This thesis documents three investigations carried out in pursuance of a doctoral degree in applied mathematics at the University of Colorado (Boulder). The first investigation concerns the properties of rotating Rayleigh-Benard convection -- thermal convection in a rotating infinite plane layer between two constant-temperature boundaries. It is noted that in certain parameter regimes convective Taylor columns appear which dominate the dynamics, and a semi-analytical model of these is presented. Investigation of the columns and of various other properties of the flow is ongoing. The second investigation concerns the interactions between planetary-scale and mesoscale dynamics in the oceans. Using multiple-scale asymptotics the possible connections between planetary geostrophic and quasigeostrophic dynamics are investigated, and three different systems of coupled equations are derived. Possible use of these equations in conjunction with the method of superparameterization, and extension of the asymptotic methods to the interactions between mesoscale and submesoscale dynamics is ongoing. The third investigation concerns the linear stability properties of semi-implicit methods for the numerical integration of ordinary differential equations, focusing in particular on the linear stability of IMEX (Implicit-Explicit) methods and exponential integrators applied to systems of ordinary differential equations arising in the numerical solution of spatially discretized nonlinear partial differential equations containing both dispersive and dissipative linear terms. While these investigations may seem unrelated at first glance, some reflection shows that they are in fact closely linked. The investigation of rotating convection makes use of single-space, multiple-time-scale asymptotics to deal with dynamics strongly constrained by rotation. Although the context of thermal convection in an infinite layer seems somewhat removed from large-scale ocean dynamics, the asymptotic

  9. A rapid Salmonella detection method involving thermophilic helicase-dependent amplification and a lateral flow assay.

    Science.gov (United States)

    Du, Xin-Jun; Zhou, Tian-Jiao; Li, Ping; Wang, Shuo

    2017-08-01

    Salmonella is a major foodborne pathogen that is widespread in the environment and can cause serious human and animal disease. Since conventional culture methods to detect Salmonella are time-consuming and laborious, rapid and accurate techniques to detect this pathogen are critically important for food safety and diagnosing foodborne illness. In this study, we developed a rapid, simple and portable Salmonella detection strategy that combines thermophilic helicase-dependent amplification (tHDA) with a lateral flow assay to provide a detection result based on visual signals within 90 min. Performance analyses indicated that the method had detection limits for DNA and pure cultured bacteria of 73.4-80.7 fg and 35-40 CFU, respectively. Specificity analyses showed no cross reactions with Escherichia coli, Staphylococcus aureus, Listeria monocytogenes, Enterobacter aerogenes, Shigella and Campylobacter jejuni. The results for detection in real food samples showed that 1.3-1.9 CFU/g or 1.3-1.9 CFU/mL of Salmonella in contaminated chicken products and infant nutritional cereal could be detected after 2 h of enrichment. The same amount of Salmonella in contaminated milk could be detected after 4 h of enrichment. This tHDA-strip can be used for the rapid detection of Salmonella in food samples and is particularly suitable for use in areas with limited equipment. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. A comparison of test statistics for the recovery of rapid growth-based enumeration tests

    NARCIS (Netherlands)

    van den Heuvel, Edwin R.; IJzerman-Boon, Pieta C.

    This paper considers five test statistics for comparing the recovery of a rapid growth-based enumeration test with respect to the compendial microbiological method using a specific nonserial dilution experiment. The finite sample distributions of these test statistics are unknown, because they are

  11. Fundamentals of rapid injection molding for microfluidic cell-based assays.

    Science.gov (United States)

    Lee, Ulri N; Su, Xiaojing; Guckenberger, David J; Dostie, Ashley M; Zhang, Tianzi; Berthier, Erwin; Theberge, Ashleigh B

    2018-01-30

    Microscale cell-based assays have demonstrated unique capabilities in reproducing important cellular behaviors for diagnostics and basic biological research. As these assays move beyond the prototyping stage and into biological and clinical research environments, there is a need to produce microscale culture platforms more rapidly, cost-effectively, and reproducibly. 'Rapid' injection molding is poised to meet this need as it enables some of the benefits of traditional high volume injection molding at a fraction of the cost. However, rapid injection molding has limitations due to the material and methods used for mold fabrication. Here, we characterize advantages and limitations of rapid injection molding for microfluidic device fabrication through measurement of key features for cell culture applications including channel geometry, feature consistency, floor thickness, and surface polishing. We demonstrate phase contrast and fluorescence imaging of cells grown in rapid injection molded devices and provide design recommendations to successfully utilize rapid injection molding methods for microscale cell-based assay development in academic laboratory settings.

  12. Bacteriophage-based nanoprobes for rapid bacteria separation

    Science.gov (United States)

    Chen, Juhong; Duncan, Bradley; Wang, Ziyuan; Wang, Li-Sheng; Rotello, Vincent M.; Nugen, Sam R.

    2015-10-01

    The lack of practical methods for bacterial separation remains a hindrance for the low-cost and successful development of rapid detection methods from complex samples. Antibody-tagged magnetic particles are commonly used to pull analytes from a liquid sample. While this method is well-established, improvements in capture efficiencies would result in an increase of the overall detection assay performance. Bacteriophages represent a low-cost and more consistent biorecognition element as compared to antibodies. We have developed nanoscale bacteriophage-tagged magnetic probes, where T7 bacteriophages were bound to magnetic nanoparticles. The nanoprobe allowed the specific recognition and attachment to E. coli cells. The phage magnetic nanprobes were directly compared to antibody-conjugated magnetic nanoprobes. The capture efficiencies of bacteriophages and antibodies on nanoparticles for the separation of E. coli K12 at varying concentrations were determined. The results indicated a similar bacteria capture efficiency between the two nanoprobes.The lack of practical methods for bacterial separation remains a hindrance for the low-cost and successful development of rapid detection methods from complex samples. Antibody-tagged magnetic particles are commonly used to pull analytes from a liquid sample. While this method is well-established, improvements in capture efficiencies would result in an increase of the overall detection assay performance. Bacteriophages represent a low-cost and more consistent biorecognition element as compared to antibodies. We have developed nanoscale bacteriophage-tagged magnetic probes, where T7 bacteriophages were bound to magnetic nanoparticles. The nanoprobe allowed the specific recognition and attachment to E. coli cells. The phage magnetic nanprobes were directly compared to antibody-conjugated magnetic nanoprobes. The capture efficiencies of bacteriophages and antibodies on nanoparticles for the separation of E. coli K12 at varying

  13. Rapid, cost-effective liquid chromatograghic method for the ...

    African Journals Online (AJOL)

    GRACE

    2006-07-03

    Jul 3, 2006 ... Akay C, Ozkan SA, Senturk Z, Cevheroglu S (2002). Simultaneous determination of metronidazole and miconazole in pharmaceutical dosage form by HPLC. Farmaco. Nov.57(11): 953-7. Galmier MJ, Frasey AM, Bastide M, Beyssac E, Petit J, Aiache JM,. Lartigue-Mattei (1998). Simple and sensitive method ...

  14. RESEARCH NOTE A Universal, rapid, and inexpensive method for ...

    Indian Academy of Sciences (India)

    Navya

    very satisfactory for many researchers to prepare reagents for “all in one” ready to use method to extract gDNA from very wide range sources of blood samples. To meet these criteria, a universal and versatile DNA extraction procedure should be developedwith a minimal chemicals and equipment.On the other hand, the ...

  15. Rapid prototyping methods for the manufacture of fuel cells

    Directory of Open Access Journals (Sweden)

    Dudek Piotr

    2016-01-01

    The potential for the application of this method for the manufacture of metallic bipolar plates (BPP for use in proton exchange membrane fuel cells (PEMFCs is presented and discussed. Special attention is paid to the fabrication of light elements for the construction of PEMFC stacks designed for mobile applications such as aviation technology and unmanned aerial vehicles (UAVs.

  16. [Methods for the rapid preparation of paraffin blocks].

    Science.gov (United States)

    Shmurun, R I

    1992-01-01

    Two accelerated chloroform-paraffin processings of materials with the use of ultrasound (US) and microwave (MW) irradiation in the stove "Electronica" as well as a combined method with US- and MW-irradiation are proposed to shorten drastically the duration of the prehistologic processing.

  17. Rapid multi-residue method for the determination of pesticide ...

    African Journals Online (AJOL)

    Exposure to pesticides can represent a potential risk to humans. Agricultural workers are at risk of chronic toxicity. Hence, the evaluation of pesticide residues in their blood gives an indication about the extent of exposure and help in assessing adverse health effects. The aim of our study was to develop analytical method for ...

  18. The method of parallel-hierarchical transformation for rapid recognition of dynamic images using GPGPU technology

    Science.gov (United States)

    Timchenko, Leonid; Yarovyi, Andrii; Kokriatskaya, Nataliya; Nakonechna, Svitlana; Abramenko, Ludmila; Ławicki, Tomasz; Popiel, Piotr; Yesmakhanova, Laura

    2016-09-01

    The paper presents a method of parallel-hierarchical transformations for rapid recognition of dynamic images using GPU technology. Direct parallel-hierarchical transformations based on cluster CPU-and GPU-oriented hardware platform. Mathematic models of training of the parallel hierarchical (PH) network for the transformation are developed, as well as a training method of the PH network for recognition of dynamic images. This research is most topical for problems on organizing high-performance computations of super large arrays of information designed to implement multi-stage sensing and processing as well as compaction and recognition of data in the informational structures and computer devices. This method has such advantages as high performance through the use of recent advances in parallelization, possibility to work with images of ultra dimension, ease of scaling in case of changing the number of nodes in the cluster, auto scan of local network to detect compute nodes.

  19. Systems and methods for rapid processing and storage of data

    Science.gov (United States)

    Stalzer, Mark A.

    2017-01-24

    Systems and methods of building massively parallel computing systems using low power computing complexes in accordance with embodiments of the invention are disclosed. A massively parallel computing system in accordance with one embodiment of the invention includes at least one Solid State Blade configured to communicate via a high performance network fabric. In addition, each Solid State Blade includes a processor configured to communicate with a plurality of low power computing complexes interconnected by a router, and each low power computing complex includes at least one general processing core, an accelerator, an I/O interface, and cache memory and is configured to communicate with non-volatile solid state memory.

  20. Non-supervised method for early forest fire detection and rapid mapping

    Science.gov (United States)

    Artés, Tomás; Boca, Roberto; Liberta, Giorgio; San-Miguel, Jesús

    2017-09-01

    Natural hazards are a challenge for the society. Scientific community efforts have been severely increased assessing tasks about prevention and damage mitigation. The most important points to minimize natural hazard damages are monitoring and prevention. This work focuses particularly on forest fires. This phenomenon depends on small-scale factors and fire behavior is strongly related to the local weather. Forest fire spread forecast is a complex task because of the scale of the phenomena, the input data uncertainty and time constraints in forest fire monitoring. Forest fire simulators have been improved, including some calibration techniques avoiding data uncertainty and taking into account complex factors as the atmosphere. Such techniques increase dramatically the computational cost in a context where the available time to provide a forecast is a hard constraint. Furthermore, an early mapping of the fire becomes crucial to assess it. In this work, a non-supervised method for forest fire early detection and mapping is proposed. As main sources, the method uses daily thermal anomalies from MODIS and VIIRS combined with land cover map to identify and monitor forest fires with very few resources. This method relies on a clustering technique (DBSCAN algorithm) and on filtering thermal anomalies to detect the forest fires. In addition, a concave hull (alpha shape algorithm) is applied to obtain rapid mapping of the fire area (very coarse accuracy mapping). Therefore, the method leads to a potential use for high-resolution forest fire rapid mapping based on satellite imagery using the extent of each early fire detection. It shows the way to an automatic rapid mapping of the fire at high resolution processing as few data as possible.

  1. SCAR makers and multiplex PCR-based rapid molecular typing of Lentinula edodes strains.

    Science.gov (United States)

    Wu, Xueqian; Li, Haibo; Zhao, Weiwei; Fu, Lizhong; Peng, Huazheng; He, Liang; Cheng, Junwen; Wei, Hailong; Wu, Qingqi

    2010-11-01

    Lentinula edodes is the second most important cultivated mushroom worldwide, the most commercial strains have been identified only through traditional phenotypic analysis. In this study, a simple rapid PCR-based molecular method was developed for distinguishing commercial strains of L. edodes by developing specific sequence characterized amplified region (SCAR) markers and establishing multiplex PCR assays with the SCAR primers. Derived from the randomly amplified polymorphic DNA (RAPD) and sequence-related amplified polymorphism (SRAP) techniques, 10 informative SCAR markers were generated from 10 polymorphic RAPD and SRAP bands. The differences in SCAR phenotypes among different strains made these SCAR markers potentially useful to characterize 6 strains and identify them from other studied strains. Moreover, different SCAR phenotypes also made the other 17 studied strains to be divided into four distinguishable groups. The multiplex PCR assays were further established for the joint use of some SCAR markers efficiently. Compared with some identification methods reported previously, the special feature of this new molecular method is technically rapid and convenient in the practical use and suitable for analyzing large numbers of samples. Thus, the simple rapid PCR-based molecular method can be used as a helpful assistant tool for the lentinula industry. To our knowledge, this study is the first to describe a development of a new SCAR maker-based multiplex PCR assay for rapid molecular typing of edible mushroom.

  2. A Simple and Rapid Data Extraction Method for the Precision Aspheric Optical Surface Height

    Science.gov (United States)

    Xing, Guohua; Peng, Yunfeng; Su, Xing

    2017-10-01

    Nowadays, the application of aspheric optics is becoming more and more popular in the precision optical engineering field. Therefore, it urges the rapid development of the precision machining and measuring technology. Generally, the aspheric optical component is measured by the interferometer. The underlying question is that the figure output by interferometer can’t be always recognized by other analysis software or program though the interferometer has its own unique data processing system. In this paper, a robust, rapid and simple method is presented to interpret the surface height data of the precision machined aspheric optical surface. The optical surface is measured by interferometer. The result figure is split into two parts, one of which is the interferogram picture of the whole aspheric optical surface and the other is the colour reference column indicating the height value. The ratios of the red (R), green (G) and blue (B) are analysed based on the middle of the colour reference column, and the corresponding relationship between the colours and surface height is established and looked as a reference data base. Then the interferogram picture of the whole aspheric optical surface is also analysed and divided according to the red (R), green (G) and blue (B) colours. By comparing the ratios and values of RGB colour, the aspheric optical surface height can be extracted approximately. The feasibility of this method was approved by the extraction processing experiment of a polished aspheric optical surface.

  3. Miniaturized fluorescent RNA dot blot method for rapid quantitation of gene expression

    Directory of Open Access Journals (Sweden)

    Yadetie Fekadu

    2004-06-01

    Full Text Available Abstract Background RNA dot blot hybridization is a commonly used technique for gene expression assays. However, membrane based RNA dot/slot blot hybridization is time consuming, requires large amounts of RNA, and is less suited for parallel assays of more than one gene at a time. Here, we describe a glass-slide based miniaturized RNA dot blot (RNA array procedure for rapid and parallel gene expression analysis using fluorescently labeled probes. Results RNA arrays were prepared by simple manual spotting of RNA onto amino-silane coated microarray glass slides, and used for two-color fluorescent hybridization with specific probes labeled with Cy3 and 18S ribosomal RNA house-keeping gene probe labeled with Cy5 fluorescent dyes. After hybridization, arrays were scanned on a fluorescent microarray scanner and images analyzed using microarray image analysis software. We demonstrate that this method gives comparable results to Northern blot analysis, and enables high throughput quantification of transcripts from nanogram quantities of total RNA in hundreds of samples. Conclusion RNA array on glass slide and detection by fluorescently labeled probes can be used for rapid and parallel gene expression analysis. The method is particularly well suited for gene expression assays that involve quantitation of many transcripts in large numbers of samples.

  4. Interaction between Rivers and Aquifers: a method for rapid Identification of Transience in Streambed Conductance

    Science.gov (United States)

    Gianni, Guillaume; Perrochet, Pierre; Vogel, Alexandre; Brunner, Philip

    2016-04-01

    Streambed hydraulic conductance controls the interactions between surface water and groundwater. In order to quantify river-aquifer dynamics, quantifying conductance is indispensable. However, the streambed conductance is often subject to transience, as a result of the erosion and deposition processes in rivers. This transience has to be quantified and considered for any approach (i.e. numerical or analytical models) aimed at quantifying exchange fluxes. Directly measuring hydraulic properties in a river yields only point values, is time-consuming and therefore not suited to detect transience of the physical properties. We present a method to continuously and rapidly monitor transience of streambed conductance. Input data are time series of stream stage and hydraulic head variations in the aquifer. The method is based on the inversion of a floodwave response. The analytical model consists of only 3 parameters: x, the distance between streambank and an observation well, α, the aquifer diffusivity and a, the retardation coefficient that is inversely proportional to the streambed conductance. Estimation of a is carried out over successive time steps in order to identify transience in streambed conductance. The method is tested on synthetic data and is applied to field data from the Rhône River and its alluvial aquifer (Switzerland). The synthetic method demonstrated the robustness of the proposed methodology. Application of the method to the field site allowed identifying transience in streambed properties, following flood events in the Rhône. This method requires transience in the surface water, and the river should not change its width significantly with a rising water level. If these conditions are fulfilled, this method allows for a rapid and effective identification of transience of streambed conductance.

  5. Dimensional Precision Research of Wax Molding Rapid Prototyping based on Droplet Injection

    Science.gov (United States)

    Mingji, Huang; Geng, Wu; yan, Shan

    2017-11-01

    The traditional casting process is complex, the mold is essential products, mold quality directly affect the quality of the product. With the method of rapid prototyping 3D printing to produce mold prototype. The utility wax model has the advantages of high speed, low cost and complex structure. Using the orthogonal experiment as the main method, analysis each factors of size precision. The purpose is to obtain the optimal process parameters, to improve the dimensional accuracy of production based on droplet injection molding.

  6. Microwave as a rapid cooking method for beef tenderness evaluation.

    Science.gov (United States)

    Silva, Douglas R G; Fernandez, Ludimila C; Torres Filho, Robledo A; Fontes, Paulo R; Ramos, Alcinéia L S; Ramos, Eduardo M

    2017-11-20

    Semitendinosus (ST) muscle steaks were grouped according to three locations (proximal, middle, and distal end), grilled to endpoint temperature of 71C or cooked for 20, 30, 40, 50, or 60 s in a microwave oven (Mw). The location did not affect (p > .05) the cooking loss (CL) or shear force (SF) values. The CL increased (p  .05) from the grill samples. None of the microwaves' SF values were different (p > .05) from the grill values, with treatments Mw30 to Mw50 showing moderate repeatability (R = 0.51-0.60) and Mw30 and Mw60 showing higher correlations (r > .71) with grill values. Cooking beef strips with a microwave is a potential method for tenderness evaluation, but requires additional study to evaluate and optimize this application in different muscles and for comparison to sensorial data. The work was intended to evaluate the possibility of using a microwave oven for cooking meat to be used in objective measurement protocols for meat tenderness and to optimize the conditions for this purpose. The use of a standardized microwave procedure allows a dramatic reduction in analysis time and may reduce error variance due to nonuniform cooking procedures. © 2017 Wiley Periodicals, Inc.

  7. A method for rapid abundance estimation of semiplanktonic meiofauna

    Science.gov (United States)

    Armonies, Werner

    2000-12-01

    Many meiofaunal copepods and plathelminths enter the tidal waters at night thus exhibiting a life-style intermediate between benthic and planktonic. At the same time, ostracods may leave their interstitial dwelling and move across the sediment surface. In laboratory experiments, the percentage of plathelminth populations emerging from the sediment varied with the species, temperature, light conditions, and the dimensions of the sediment cores studied, but not with tidal level, season, ambient density of conspecifics, or the sediment composition. Therefore, the swimming activity may be utilised for extraction of semiplanktonic meiofauna provided that the extraction procedure is standardised with respect to temperature, light and core size. For free-living plathelminths from the Wadden Sea intertidal a robust standard procedure is as follows: sediment cores 1.6 cm in diameter (2 cm2 surface area) and 3 cm deep are fitted into cylindrical containers and submerged into aquaria containing filtered seawater (ambient salinity, room temperature, darkness) for 24 h. The sediment containers are then removed and the aquarian water filtered through appropriate meshes; the residue contains the emergent faunal component. For plathelminths, this procedure reduces sorting time by some 90% compared with the standard shaking-decantation method and thus makes it possible to process a high number of samples in a short time. Similar procedures may be developed for copepods and epibenthic ostracods.

  8. Development of rapid methods for relaxation time mapping and motion estimation using magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Gilani, Syed Irtiza Ali

    2008-09-15

    Recent technological developments in the field of magnetic resonance imaging have resulted in advanced techniques that can reduce the total time to acquire images. For applications such as relaxation time mapping, which enables improved visualisation of in vivo structures, rapid imaging techniques are highly desirable. TAPIR is a Look- Locker-based sequence for high-resolution, multislice T{sub 1} relaxation time mapping. Despite the high accuracy and precision of TAPIR, an improvement in the k-space sampling trajectory is desired to acquire data in clinically acceptable times. In this thesis, a new trajectory, termed line-sharing, is introduced for TAPIR that can potentially reduce the acquisition time by 40 %. Additionally, the line-sharing method was compared with the GRAPPA parallel imaging method. These methods were employed to reconstruct time-point images from the data acquired on a 4T high-field MR research scanner. Multislice, multipoint in vivo results obtained using these methods are presented. Despite improvement in acquisition speed, through line-sharing, for example, motion remains a problem and artefact-free data cannot always be obtained. Therefore, in this thesis, a rapid technique is introduced to estimate in-plane motion. The presented technique is based on calculating the in-plane motion parameters, i.e., translation and rotation, by registering the low-resolution MR images. The rotation estimation method is based on the pseudo-polar FFT, where the Fourier domain is composed of frequencies that reside in an oversampled set of non-angularly, equispaced points. The essence of the method is that unlike other Fourier-based registration schemes, the employed approach does not require any interpolation to calculate the pseudo-polar FFT grid coordinates. Translation parameters are estimated by the phase correlation method. However, instead of two-dimensional analysis of the phase correlation matrix, a low complexity subspace identification of the phase

  9. Appropriate targeting of artemisinin-based combination therapy by community health workers using malaria rapid diagnostic tests

    DEFF Research Database (Denmark)

    Ndyomugyenyi, Richard; Magnussen, Pascal; Lal, Sham

    2016-01-01

    OBJECTIVE: To compare the impact of malaria rapid diagnostic tests (mRDTs), used by community health workers (CHWs), on the proportion of children artemisinin-based combination therapy (ACT), vs. presumptive treatment. METHODS: Cluster...

  10. Evidence-based medicine in rapidly changing technologies

    DEFF Research Database (Denmark)

    Schroeder, Torben Veith

    2008-01-01

    Evidence-based medicine (EBM) is not a randomised controlled trial (RCT), but EBM seeks to apply evidence gained from scientific methods - which could be RCT - to daily medical practice. Any surgical treatment reflects a certain development technically as well as skills based. The procedure may...

  11. A rapid and sensitive method for measuring N-acetylglucosaminidase activity in cultured cells.

    Directory of Open Access Journals (Sweden)

    Victor Mauri

    Full Text Available A rapid and sensitive method to quantitatively assess N-acetylglucosaminidase (NAG activity in cultured cells is highly desirable for both basic research and clinical studies. NAG activity is deficient in cells from patients with Mucopolysaccharidosis type IIIB (MPS IIIB due to mutations in NAGLU, the gene that encodes NAG. Currently available techniques for measuring NAG activity in patient-derived cell lines include chromogenic and fluorogenic assays and provide a biochemical method for the diagnosis of MPS IIIB. However, standard protocols require large amounts of cells, cell disruption by sonication or freeze-thawing, and normalization to the cellular protein content, resulting in an error-prone procedure that is material- and time-consuming and that produces highly variable results. Here we report a new procedure for measuring NAG activity in cultured cells. This procedure is based on the use of the fluorogenic NAG substrate, 4-Methylumbelliferyl-2-acetamido-2-deoxy-alpha-D-glucopyranoside (MUG, in a one-step cell assay that does not require cell disruption or post-assay normalization and that employs a low number of cells in 96-well plate format. We show that the NAG one-step cell assay greatly discriminates between wild-type and MPS IIIB patient-derived fibroblasts, thus providing a rapid method for the detection of deficiencies in NAG activity. We also show that the assay is sensitive to changes in NAG activity due to increases in NAGLU expression achieved by either overexpressing the transcription factor EB (TFEB, a master regulator of lysosomal function, or by inducing TFEB activation chemically. Because of its small format, rapidity, sensitivity and reproducibility, the NAG one-step cell assay is suitable for multiple procedures, including the high-throughput screening of chemical libraries to identify modulators of NAG expression, folding and activity, and the investigation of candidate molecules and constructs for applications in

  12. VIP Barcoding: composition vector-based software for rapid species identification based on DNA barcoding.

    Science.gov (United States)

    Fan, Long; Hui, Jerome H L; Yu, Zu Guo; Chu, Ka Hou

    2014-07-01

    Species identification based on short sequences of DNA markers, that is, DNA barcoding, has emerged as an integral part of modern taxonomy. However, software for the analysis of large and multilocus barcoding data sets is scarce. The Basic Local Alignment Search Tool (BLAST) is currently the fastest tool capable of handling large databases (e.g. >5000 sequences), but its accuracy is a concern and has been criticized for its local optimization. However, current more accurate software requires sequence alignment or complex calculations, which are time-consuming when dealing with large data sets during data preprocessing or during the search stage. Therefore, it is imperative to develop a practical program for both accurate and scalable species identification for DNA barcoding. In this context, we present VIP Barcoding: a user-friendly software in graphical user interface for rapid DNA barcoding. It adopts a hybrid, two-stage algorithm. First, an alignment-free composition vector (CV) method is utilized to reduce searching space by screening a reference database. The alignment-based K2P distance nearest-neighbour method is then employed to analyse the smaller data set generated in the first stage. In comparison with other software, we demonstrate that VIP Barcoding has (i) higher accuracy than Blastn and several alignment-free methods and (ii) higher scalability than alignment-based distance methods and character-based methods. These results suggest that this platform is able to deal with both large-scale and multilocus barcoding data with accuracy and can contribute to DNA barcoding for modern taxonomy. VIP Barcoding is free and available at http://msl.sls.cuhk.edu.hk/vipbarcoding/. © 2014 John Wiley & Sons Ltd.

  13. An FPGA-based rapid wheezing detection system.

    Science.gov (United States)

    Lin, Bor-Shing; Yen, Tian-Shiue

    2014-01-29

    Wheezing is often treated as a crucial indicator in the diagnosis of obstructive pulmonary diseases. A rapid wheezing detection system may help physicians to monitor patients over the long-term. In this study, a portable wheezing detection system based on a field-programmable gate array (FPGA) is proposed. This system accelerates wheezing detection, and can be used as either a single-process system, or as an integrated part of another biomedical signal detection system. The system segments sound signals into 2-second units. A short-time Fourier transform was used to determine the relationship between the time and frequency components of wheezing sound data. A spectrogram was processed using 2D bilateral filtering, edge detection, multithreshold image segmentation, morphological image processing, and image labeling, to extract wheezing features according to computerized respiratory sound analysis (CORSA) standards. These features were then used to train the support vector machine (SVM) and build the classification models. The trained model was used to analyze sound data to detect wheezing. The system runs on a Xilinx Virtex-6 FPGA ML605 platform. The experimental results revealed that the system offered excellent wheezing recognition performance (0.912). The detection process can be used with a clock frequency of 51.97 MHz, and is able to perform rapid wheezing classification.

  14. Colloidal gold probe based rapid immunochromatographic strip assay for cortisol

    Energy Technology Data Exchange (ETDEWEB)

    Nara, Seema, E-mail: seemanara@mnnit.ac.in [Department of Applied Mechanics (Biotechnology), Motilal Nehru National Institute of Technology, Allahabad 211004 (India); Department of Reproductive Biomedicine, National Institute of Health and Family Welfare, Munirka, New Delhi 110067 (India); Center for BioMedical Engineering, Indian Institute of Technology, New Delhi 110016 (India); Tripathi, Vinay [Department of Reproductive Biomedicine, National Institute of Health and Family Welfare, Munirka, New Delhi 110067 (India); Center for BioMedical Engineering, Indian Institute of Technology, New Delhi 110016 (India); Singh, Harpal [Center for BioMedical Engineering, Indian Institute of Technology, New Delhi 110016 (India); Shrivastav, Tulsidas G. [Department of Reproductive Biomedicine, National Institute of Health and Family Welfare, Munirka, New Delhi 110067 (India)

    2010-12-03

    A rapid and semi-quantitative immunochromatographic strip (ICS) test for cortisol analysis in serum was developed. The test strip was based on a competitive assay format. Colloidal gold nanoparticles were synthesized and coupled with cortisol-3-carboxymethyloxime-adipic acid dihydrazide-bovine serum albumin (F-3-CMO-ADH-BSA) antigen to directly compete with cortisol in human serum samples. F-3-CMO-ADH-BSA-gold label and uncoupled colloidal gold nanoparticles were appropriately characterized using UV-vis spectroscopy, transmission electron microscopy and atomic force microscopy. Anticortisol antibody raised against F-3-CMO-BSA immunogen in New Zealand white rabbits was coated on the NC membrane as test line. Anti-BSA antibody was used as control line. The lower detection limit of the ICS test was 30 ng mL{sup -1} with visual detection and was completed in 10 min. About 30 human serum samples were also analyzed by the developed strip test and their range of cortisol concentration was established. The developed ICS test is rapid, economic and user friendly.

  15. A rapid and simple pretreatment method for benzoylurea insecticides in honey samples using in-syringe dispersive liquid-liquid microextraction based on the direct solidification of ionic liquids.

    Science.gov (United States)

    Wang, Huazi; Hu, Lu; Li, Wanzhen; Lu, Runhua; Zhang, Sanbing; Zhou, Wenfeng; Gao, Haixiang

    2016-11-04

    A pretreatment method using in-syringe dispersive liquid-liquid microextraction based on the direct solidification of ionic liquids before high performance liquid chromatography analysis was developed for the determination of benzoylurea insecticides (BUs) in honey samples. The hydrophobic ionic liquid [N4444][PF6], formed in situ by the hydrophilic ionic liquid [N4444]Cl and the ion exchange reagent KPF6, was used to extract the target analytes. The entire extraction procedure was performed in a syringe. The extractant was solidified at room temperature and collected using a nylon membrane filter. This technique did not require a dispersive solvent, vortex mixer, ultrasound bath, or centrifugation. The parameters affecting the extraction efficiency were investigated through an experimental design. Under the optimal conditions, the limits of detection for the four BUs varied from 0.21 to 0.42μgL-1 in solution (2.1-4.2μgkg-1 in honey). Good linearities were obtained in the range of 2-300μgL-1, with coefficients of determination greater than 0.999. The recoveries of the four BUs ranged from 80.94% to 84.59%. The intra-day (n=3) and inter-day (n=3) relative standard deviations were less than 5.08%. Finally, the proposed method was applied to the determination of BUs in commercial honey samples with satisfactory results. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. A new method for rapid determination of carbohydrate and total carbon concentrations using UV spectrophotometry.

    Science.gov (United States)

    Albalasmeh, Ammar A; Berhe, Asmeret Asefaw; Ghezzehei, Teamrat A

    2013-09-12

    A new UV spectrophotometry based method for determining the concentration and carbon content of carbohydrate solution was developed. This method depends on the inherent UV absorption potential of hydrolysis byproducts of carbohydrates formed by reaction with concentrated sulfuric acid (furfural derivatives). The proposed method is a major improvement over the widely used Phenol-Sulfuric Acid method developed by DuBois, Gilles, Hamilton, Rebers, and Smith (1956). In the old method, furfural is allowed to develop color by reaction with phenol and its concentration is detected by visible light absorption. Here we present a method that eliminates the coloration step and avoids the health and environmental hazards associated with phenol use. In addition, avoidance of this step was shown to improve measurement accuracy while significantly reducing waiting time prior to light absorption reading. The carbohydrates for which concentrations and carbon content can be reliably estimated with this new rapid Sulfuric Acid-UV technique include: monosaccharides, disaccharides and polysaccharides with very high molecular weight. Copyright © 2013 Elsevier Ltd. All rights reserved.

  17. Methods in Logic Based Control

    DEFF Research Database (Denmark)

    Christensen, Georg Kronborg

    1999-01-01

    Desing and theory of Logic Based Control systems.Boolean Algebra, Karnaugh Map, Quine McClusky's algorithm. Sequential control design. Logic Based Control Method, Cascade Control Method. Implementation techniques: relay, pneumatic, TTL/CMOS,PAL and PLC- and Soft_PLC implementation. PLC...

  18. Rapid and label-free bioanalytical method of alpha fetoprotein detection using LSPR chip

    Science.gov (United States)

    Kim, Dongjoo; Kim, Jinwoon; Kwak, Cheol Hwan; Heo, Nam Su; Oh, Seo Yeong; Lee, Hoomin; Lee, Go-Woon; Vilian, A. T. Ezhil; Han, Young-Kyu; Kim, Woo-Sik; Kim, Gi-bum; Kwon, Soonjo; Huh, Yun Suk

    2017-07-01

    Alpha fetoprotein (AFP) is a cancer marker, particularly for hepatocellular carcinoma. Normal levels of AFP are less than 20 ng/mL; however, its levels can reach more than 400 ng/mL in patients with HCC. Enzyme linked immunosorbent assay (ELISA) and radioimmunoassay (RIA) have been employed for clinical diagnosis of AFP; however, these methods are time consuming and labor intensive. In this study, we developed a localized surface plasmon resonance (LSPR) based biosensor for simple and rapid detection of AFP. This biosensor consists of a UV-Vis spectrometer, a cuvette cell, and a biosensor chip nanopatterned with gold nanoparticles (AuNPs). In our LSPR biosensor, binding of AFP to the surface of the sensor chip led to an increasing magnitude of the LSPR signals, which was measured by an ultraviolet-visible (UV-Vis) spectrometer. Our LSPR biosensor showed sufficient detectability of AFP at concentrations of 1 ng/mL to 1 μg/mL. Moreover, the overall procedure for detection of AFP was completed within 20 min. This biosensor could also be utilized for a point of care test (POCT) by employing a portable UV-Vis spectrometer. Owing to the simplicity and rapidity of the detection process, our LSPR biosensor is expected to replace traditional diagnostic methods for the early detection of diseases.

  19. Methods and Magnitudes of Rapid Weight Loss in Judo Athletes Over Pre-Competition Periods

    Directory of Open Access Journals (Sweden)

    Kons Rafael Lima

    2017-06-01

    Full Text Available Purpose. The study aimed to analyse the methods and magnitudes of rapid weight loss (RWL in judo team members in distinct periods before the biggest state competition in Southern Brazil.

  20. A rapid and efficient electroporation method for transformation of Halomonas sp. O-1.

    Science.gov (United States)

    Harris, Joshua R; Lundgren, Benjamin R; Grzeskowiak, Brian R; Mizuno, Kouhei; Nomura, Christopher T

    2016-10-01

    Halomonas sp. O-1 is a halophilic bacterium with a high potential for industrial application due to its natural ability to produce polyhydroxyalkanoates (PHAs) using seawater-based media. However, a major barrier preventing industrial scale implementation of this organism is a lack of molecular methodologies capable of readily transforming members of the Halomonas genus. Currently, the only reliable method used for introducing DNA into Halomonas spp. is bacterial conjugation, a somewhat tedious and time-consuming technique compared to electroporation-based methodologies. Here we describe a rapid and reproducible method for the electroporation of Halomonas sp. O-1 with plasmid DNA. Electrocompetent cells were generated by growing Halomonas sp. O-1 in a yeast extract-tryptone medium with a final salinity of 3.5%, pH of 7.5, followed by several washes using 300mM sucrose. Results show that plasmids containing chloramphenicol (Cm(R)) and gentamicin (Gm(R)) resistance cassettes are suitable antibiotic selection markers for transformation and yields of 10(4) transformants per μg of DNA were obtained. This method is simple to perform and the materials used are readily available in most research labs. Additionally, this plasmid-based transformation procedure has the potential to be adapted for a number of applications including the creation of recombinant stains and the generation of deletion mutants of Halomonas spp. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Bacterial Cytological Profiling (BCP as a Rapid and Accurate Antimicrobial Susceptibility Testing Method for Staphylococcus aureus

    Directory of Open Access Journals (Sweden)

    D.T. Quach

    2016-02-01

    Full Text Available Successful treatment of bacterial infections requires the timely administration of appropriate antimicrobial therapy. The failure to initiate the correct therapy in a timely fashion results in poor clinical outcomes, longer hospital stays, and higher medical costs. Current approaches to antibiotic susceptibility testing of cultured pathogens have key limitations ranging from long run times to dependence on prior knowledge of genetic mechanisms of resistance. We have developed a rapid antimicrobial susceptibility assay for Staphylococcus aureus based on bacterial cytological profiling (BCP, which uses quantitative fluorescence microscopy to measure antibiotic induced changes in cellular architecture. BCP discriminated between methicillin-susceptible (MSSA and -resistant (MRSA clinical isolates of S. aureus (n = 71 within 1–2 h with 100% accuracy. Similarly, BCP correctly distinguished daptomycin susceptible (DS from daptomycin non-susceptible (DNS S. aureus strains (n = 20 within 30 min. Among MRSA isolates, BCP further identified two classes of strains that differ in their susceptibility to specific combinations of beta-lactam antibiotics. BCP provides a rapid and flexible alternative to gene-based susceptibility testing methods for S. aureus, and should be readily adaptable to different antibiotics and bacterial species as new mechanisms of resistance or multidrug-resistant pathogens evolve and appear in mainstream clinical practice.

  2. Use of a modified cluster sampling method to perform rapid needs assessment after Hurricane Andrew.

    Science.gov (United States)

    Hlady, W G; Quenemoen, L E; Armenia-Cope, R R; Hurt, K J; Malilay, J; Noji, E K; Wurm, G

    1994-04-01

    To rapidly obtain population-based estimates of needs in the early aftermath of Hurricane Andrew in South Florida. We used a modified cluster-sampling method (the Expanded Programme on Immunization [EPI] method) for three surveys. We selected a systematic sample of 30 quarter-mile square clusters for each survey and, beginning from a random start, interviewed members of seven consecutive occupied households in each cluster. Two surveys were of the most affected area (1990 population, 32,672) at three and ten days after the hurricane struck; one survey was of a less affected area (1990 population, 15,576) seven days after the hurricane struck. Results were available within 24 hours of beginning each survey. Initial findings emphasized the need for restoring utilities and sanitation and helped to focus medical relief on primary care and preventive services. The second survey of the most affected area showed improvement in the availability of food, water, electricity, and sanitation (P < or = .05). There was no evidence of disease outbreaks. For the first time, the EPI method provided population-based information to guide and evaluate relief operations after a sudden-impact natural disaster. An improvement over previous approaches, the EPI method warrants further evaluation as a needs assessment tool in acute disasters.

  3. Activity based costing (ABC Method

    Directory of Open Access Journals (Sweden)

    Prof. Ph.D. Saveta Tudorache

    2008-05-01

    Full Text Available In the present paper the need and advantages are presented of using the Activity BasedCosting method, need arising from the need of solving the information pertinence issue. This issue has occurreddue to the limitation of classic methods in this field, limitation also reflected by the disadvantages ofsuch classic methods in establishing complete costs.

  4. Activity based costing (ABC Method)

    OpenAIRE

    Prof. Ph.D. Saveta Tudorache; University Lecturer Anca Bratu

    2008-01-01

    In the present paper the need and advantages are presented of using the Activity Based Costing method, need arising from the need of solving the information pertinence issue. This issue has occurred due to the limitation of classic methods in this field, limitation also reflected by the disadvantages of such classic methods in establishing complete costs.

  5. Development of Nylon Based FDM Filament for Rapid Tooling Application

    Science.gov (United States)

    Singh, R.; Singh, S.

    2014-04-01

    There has been critical need for development of cost effective nylon based wire to be used as feed stock filament for fused deposition modelling (FDM) machine. But hitherto, very less work has been reported for development of alternate solution of acrylonitrile butadiene styrene (ABS) based wire which is presently used in most of FDM machines. The present research work is focused on development of nylon based wire as an alternative of ABS wire (which is to be used as feedstock filament on FDM) without changing any hardware or software of machine. For the present study aluminium oxide (Al2O3) as additive in different proportion has been used with nylon fibre. Single screw extruder was used for wire preparation and wire thus produced was tested on FDM. Mechanical properties i.e. tensile strength and percentage elongation of finally developed wire have been optimized by Taguchi L9 technique. The work represented major development in reducing cost and time in rapid tooling applications.

  6. Rapid identification of salmonella serotypes with stereo and hyperspectral microscope imaging Methods

    Science.gov (United States)

    The hyperspectral microscope imaging (HMI) method can reduce detection time within 8 hours including incubation process. The early and rapid detection with this method in conjunction with the high throughput capabilities makes HMI method a prime candidate for implementation for the food industry. Th...

  7. A rapid minor groove binder PCR method for distinguishing the vaccine strain Brucella abortus 104M.

    Science.gov (United States)

    Nan, Wenlong; Qin, Lide; Wang, Yong; Zhang, Yueyong; Tan, Pengfei; Chen, Yuqi; Mao, Kairong; Chen, Yiping

    2018-01-24

    Brucellosis is a widespread zoonotic disease caused by Gram-negative Brucella bacteria. Immunisation with attenuated vaccine is an effective method of prevention, but it can interfere with diagnosis. Live, attenuated Brucella abortus strain 104M has been used for the prevention of human brucellosis in China since 1965. However, at present, no fast and reliable method exists that can distinguish this strain from field strains. Single nucleotide polymorphism (SNP)-based assays offer a new approach for such discrimination. SNP-based minor groove binder (MGB) and Cycleave assays have been used for rapid identification of four Brucella vaccine strains (B. abortus strains S19, A19 and RB51, and B. melitensis Rev1). The main objective of this study was to develop a PCR assay for rapid and specific detection of strain 104M. We developed a SNP-based MGB PCR assay that could successfully distinguish strain 104M from 18 representative strains of Brucella (B. abortus biovars 1, 2, 3, 4, 5, 6, 7 and 9, B. melitensis biovars 1, 2 and 3, B. suis biovars 1, 2, 3 and 4, B. canis, B. neotomae, and B. ovis), four Brucella vaccine strains (A19, S19, S2, M5), and 55 Brucella clinical field strains. The assay gave a negative reaction with four non-Brucella species (Escherichia coli, Pasteurella multocida, Streptococcus suis and Pseudomonas aeruginosa). The minimum sensitivity of the assay, evaluated using 10-fold dilutions of chromosomal DNA, was 220 fg for the 104M strain and 76 fg for the single non-104M Brucella strain tested (B. abortus A19). The assay was also reproducible (intra- and inter-assay coefficients of variation = 0.006-0.022 and 0.012-0.044, respectively). A SNP-based MGB PCR assay was developed that could straightforwardly and unambiguously distinguish B. abortus vaccine strain 104M from non-104M Brucella strains. Compared to the classical isolation and identification approaches of bacteriology, this real-time PCR assay has substantial advantages in terms of

  8. Assessment of three rapid methods for the detection of methicillin-resistant Staphylococcus aureus.

    Science.gov (United States)

    Soares, Maria João; Soares, Carlos; Mendes, Ana Constança; Guimarães, Maria Luís; Cabeda, José Manuel; Amorim, José Manuel

    2004-01-01

    We evaluated three rapid methods to detect methicillin-resistant Staphylococcus aureus (MRSA) and compared them with PCR amplification of mecA. A total of 103 S. aureus strains were studied by MRSA-Screen, BBL Crystal, Velogene Genomic and mecA PCR. All the methods detected the 61 MRSA strains having the mecA gene, showing 100% sensitivity and specificity. Despite the correlation between all the rapid methods and PCR, the ease of use and shorter turnaround time of MRSA-Screen were important factors leading to the selection of this method as the routine screening technique for MRSA.

  9. A simple electrochemical method for the rapid estimation of antioxidant potentials of some selected medicinal plants.

    Science.gov (United States)

    Amidi, Salimeh; Mojab, Faraz; Bayandori Moghaddam, Abdolmajid; Tabib, Kimia; Kobarfard, Farzad

    2012-01-01

    Clinical and Epidemiological studies have shown that a diet rich in fruits and vegetables is associated with a decreased risk of cardiovascular diseases, cancers and other related disorders. These beneficial health effects have been attributed in part to the presence of antioxidants in dietary plants. Therefore screening for antioxidant properties of plant extracts has been one of the interests of scientists in this field. Different screening methods have been reported for the evaluation of antioxidant properties of plant extracts in the literature. In the present research a rapid screening method has been introduced based on cyclic voltammetry for antioxidant screening of some selected medicinal plant extracts. CYCLIC VOLTAMMETRY OF METHANOLIC EXTRACTS OF SEVEN MEDICINAL PLANTS: Buxus hyrcana, Rumex crispus, Achillea millefolium, Zataria multiflora, Ginkgo biloba, Lippia citriodora and Heptaptera anisoptera was carried out at different scan rates. Based on the interpretation of voltammograms, Rumex crispus, Achillea millefolium and Ginkgo biloba showed higher antioxidant capability than the others while Lippia citriodora contained the highest amount of antioxidants. Cyclic voltammetry is expected to be a simple method for screening antioxidants and estimating the antioxidant activity of foods and medicinal plants.

  10. Rapid, convenient method for screening imidazole-containing compounds for heme oxygenase inhibition.

    Science.gov (United States)

    Vlahakis, Jason Z; Rahman, Mona N; Roman, Gheorghe; Jia, Zongchao; Nakatsu, Kanji; Szarek, Walter A

    2011-01-01

    Sensitive assays for measuring heme oxygenase activity have been based on the gas-chromatographic detection of carbon monoxide using elaborate, expensive equipment. The present study describes a rapid and convenient method for screening imidazole-containing candidates for inhibitory activity against heme oxygenase using a plate reader, based on the spectroscopic evaluation of heme degradation. A PowerWave XS plate reader was used to monitor the absorbance (as a function of time) of heme bound to purified truncated human heme oxygenase-1 (hHO-1) in the individual wells of a standard 96-well plate (with or without the addition of a test compound). The degradation of heme by heme oxygenase-1 was initiated using l-ascorbic acid, and the collected relevant absorbance data were analyzed by three different methods to calculate the percent control activity occurring in wells containing test compounds relative to that occurring in control wells with no test compound present. In the cases of wells containing inhibitory compounds, significant shifts in λ(max) from 404 to near 412 nm were observed as well as a decrease in the rate of heme degradation relative to that of the control. Each of the three methods of data processing (overall percent drop in absorbance over 1.5h, initial rate of reaction determined over the first 5 min, and estimated pseudo first-order reaction rate constant determined over 1.5h) gave similar and reproducible results for percent control activity. The fastest and easiest method of data analysis was determined to be that using initial rates, involving data acquisition for only 5 min once reactions have been initiated using l-ascorbic acid. The results of the study demonstrate that this simple assay based on the spectroscopic detection of heme represents a rapid, convenient method to determine the relative inhibitory activity of candidate compounds, and is useful in quickly screening a series or library of compounds for heme oxygenase inhibition

  11. A rapid method of detecting autoantibody against FcεRIα for chronic spontaneous urticaria.

    Directory of Open Access Journals (Sweden)

    Mey-Fann Lee

    Full Text Available BACKGROUND: Chronic spontaneous urticaria (CU is a common skin disorder, with an estimated prevalence of 0.5-1.8% in most populations. Around 30-50% of CU patients have an autoimmune etiology, with autoantibodies (autoAbs against IgE, FcεRIα, and FcεRII/CD23. Although the in vivo autologous serum skin test (ASST and in vitro histamine release/activation assay are the most frequently used screening methods, these two have many limitations and do not directly measure susceptible autoAbs. This study aimed to establish an in vitro rapid screening test using recombinant autoantigen FcεRIα(rFcεRIα to improve the diagnosis of autoimmune urticaria. METHODS: Forty patients with CU and 20 healthy individuals were enrolled. After PCR-based cloning and the production of extracellular fragments of the FcεRIα protein using the E. coli expression system, serum autoAb to rFcεRIα was evaluated using in-house ELISA and rapid immunodot test. RESULTS: In ELISA-based detection, 14 out of 20 CU-ASST(+ patients exhibited anti- FcεRIα responses, whereas five of the 20 CU-ASST(- and two of the 20 non-CU patients showed autoantibody background in the assay. For the immunodot test, 55% (11/20 of the CU-ASST(+ sera exhibited anti-FcεRIα reactivity. There was no false positive among the CU-ASST(- and non-CU groups. Using clinical urticaria plus ASST(+ as the gold standard, in-house ELISA had 70% sensitivity, 82.5% specificity, and positive likelihood ratio of 4, while immunodot had 55% sensitivity, 100% specificity, and positive likelihood ratio >55. CONCLUSIONS: This study has developed a rapid immunodot method with high specificity for detecting autoAb to FcεRIαin patients with CU. Preliminary data indicates that this immunodot technique has the potential to be a routine diagnostic assay for autoimmune CU.

  12. Rapid bacterial antibiotic susceptibility test based on simple surface-enhanced Raman spectroscopic biomarkers

    Science.gov (United States)

    Liu, Chia-Ying; Han, Yin-Yi; Shih, Po-Han; Lian, Wei-Nan; Wang, Huai-Hsien; Lin, Chi-Hung; Hsueh, Po-Ren; Wang, Juen-Kai; Wang, Yuh-Lin

    2016-03-01

    Rapid bacterial antibiotic susceptibility test (AST) and minimum inhibitory concentration (MIC) measurement are important to help reduce the widespread misuse of antibiotics and alleviate the growing drug-resistance problem. We discovered that, when a susceptible strain of Staphylococcus aureus or Escherichia coli is exposed to an antibiotic, the intensity of specific biomarkers in its surface-enhanced Raman scattering (SERS) spectra drops evidently in two hours. The discovery has been exploited for rapid AST and MIC determination of methicillin-susceptible S. aureus and wild-type E. coli as well as clinical isolates. The results obtained by this SERS-AST method were consistent with that by the standard incubation-based method, indicating its high potential to supplement or replace existing time-consuming methods and help mitigate the challenge of drug resistance in clinical microbiology.

  13. Leveraging rapid community-based hiv testing campaigns for non-communicable diseases in rural uganda

    OpenAIRE

    Gabriel Chamie; Dalsone Kwarisiima; Clark, Tamara D; Jane Kabami; Vivek Jain; Elvin Geng; Petersen, Maya L; Harsha Thirumurthy; Moses R Kamya; Havlir, Diane V.; Charlebois, Edwin D.

    2012-01-01

    Background The high burden of undiagnosed HIV in sub-Saharan Africa limits treatment and prevention efforts. Community-based HIV testing campaigns can address this challenge and provide an untapped opportunity to identify non-communicable diseases (NCDs). We tested the feasibility and diagnostic yield of integrating NCD and communicable diseases into a rapid HIV testing and referral campaign for all residents of a rural Ugandan parish. Methods A five-day, multi-disease campaign, offering diag...

  14. OSO paradigm--A rapid behavioral screening method for acute psychosocial stress reactivity in mice.

    Science.gov (United States)

    Brzózka, M M; Unterbarnscheidt, T; Schwab, M H; Rossner, M J

    2016-02-09

    Chronic psychosocial stress is an important environmental risk factor for the development of psychiatric diseases. However, studying the impact of chronic psychosocial stress in mice is time consuming and thus not optimally suited to 'screen' increasing numbers of genetically manipulated mouse models for psychiatric endophenotypes. Moreover, many studies focus on restraint stress, a strong physical stressor with limited relevance for psychiatric disorders. Here, we describe a simple and a rapid method based on the resident-intruder paradigm to examine acute effects of mild psychosocial stress in mice. The OSO paradigm (open field--social defeat--open field) compares behavioral consequences on locomotor activity, anxiety and curiosity before and after exposure to acute social defeat stress. We first evaluated OSO in male C57Bl/6 wildtype mice where a single episode of social defeat reduced locomotor activity, increased anxiety and diminished exploratory behavior. Subsequently, we applied the OSO paradigm to mouse models of two schizophrenia (SZ) risk genes. Transgenic mice with neuronal overexpression of Neuregulin-1 (Nrg1) type III showed increased risk-taking behavior after acute stress exposure suggesting that NRG1 dysfunction is associated with altered affective behavior. In contrast, Tcf4 transgenic mice displayed a normal stress response which is in line with the postulated predominant contribution of TCF4 to cognitive deficits of SZ. In conclusion, the OSO paradigm allows for rapid screening of selected psychosocial stress-induced behavioral endophenotypes in mouse models of psychiatric diseases. Copyright © 2015 IBRO. Published by Elsevier Ltd. All rights reserved.

  15. ATP bioluminescence method: tool for rapid screening of organic and microbial contaminants on deteriorated mural paintings.

    Science.gov (United States)

    Unković, Nikola; Ljaljević Grbić, Milica; Stupar, Miloš; Vukojević, Jelena; Subakov-Simić, Gordana; Jelikić, Aleksa; Stanojević, Dragan

    2015-11-24

    The extent of the microbial contamination of the seventeenth-century wall paintings in the nave of the old Church of the Holy Ascension (Veliki Krčimir, Serbia) was evaluated via newly implemented ATP bioluminescence method, and traditional cultivation-based method, utilising commercially available dip slides. To assess the validity of ATP, as a biomarker for rapid detection of mural surface contamination, obtained zones of cleanliness values, in range from 1.0 to 5.3, were compared to documented total microbial counts, ranging between seven and 247 CFU/cm 2 . Small coefficients of determination, 0.0106-0.0385, suggest poor correlation between microbial counts and surface ATP levels; however, zones of cleanliness values are of great help in determining the high points of contamination, aka 'hotspots', which should be given special attention during sampling and investigation using other methods. In addition, various aspects of the possible implementation of the ATP bioluminescence method in an integrated system of wall painting conservation are discussed.

  16. Computationally rapid method of estimating signal-to-noise ratio for phased array image reconstructions.

    Science.gov (United States)

    Wiens, Curtis N; Kisch, Shawn J; Willig-Onwuachi, Jacob D; McKenzie, Charles A

    2011-10-01

    Measuring signal-to-noise ratio (SNR) for parallel MRI reconstructions is difficult due to spatially dependent noise amplification. Existing approaches for measuring parallel MRI SNR are limited because they are not applicable to all reconstructions, require significant computation time, or rely on repeated image acquisitions. A new SNR estimation approach is proposed, a hybrid of the repeated image acquisitions method detailed in the National Electrical Manufacturers Association (NEMA) standard and the Monte Carlo based pseudo-multiple replica method, in which the difference between images reconstructed from the unaltered acquired data and that same data reconstructed after the addition of calibrated pseudo-noise is used to estimate the noise in the parallel MRI image reconstruction. This new noise estimation method can be used to rapidly compute the pixel-wise SNR of the image generated from any parallel MRI reconstruction of a single acquisition. SNR maps calculated with the new method are validated against existing SNR calculation techniques. Copyright © 2011 Wiley-Liss, Inc.

  17. A rapid and sensitive method for the detection of aromatic amines in cosmetics.

    Science.gov (United States)

    Hailong, Xiao; Fen, Qian; Ying, Xu; Jianhong, Pan; Haiyun, Tu; Hongqing, Wang; Saijun, Lin; Jichun, Han

    2014-02-01

    Aromatic amines (AAs) are common chemical pollutants and banned ingredients in cosmetics. In this study, a rapid, simple and stable method for the detection of nine AAs in cosmetics was established based on the optimization of cation exchange solid-phase extraction and liquid chromatography tandem mass spectrometry. The method displayed good linearity within a range of 2-1,000 µg/kg, with limits of quantitation at the level of µg/kg for cosmetic samples. The recoveries obtained for all analyzed amines ranged between 83.6 and 97.8%, and the repeatability (r) and reproducibility (R) values indicated that all nine AAs showed good precision (r ≤ 4.5% and R ≤ 7.7%). The method was applied for the detection of 36 cosmetic samples. It was found that the primary pollutants of AAs were 3, 3'-dichlorobenzidine and 4-aminoazobenzene. The total amine concentration in cosmetic samples ranged from 880 to 5,200 µg/kg. The proposed method is applicable for the analysis of most cosmetic samples.

  18. The Simulation-Based Assessment of Pediatric Rapid Response Teams.

    Science.gov (United States)

    Fehr, James J; McBride, Mary E; Boulet, John R; Murray, David J

    2017-09-01

    To create scenarios of simulated decompensating pediatric patients to train pediatric rapid response teams (RRTs) and to determine whether the scenario scores provide a valid assessment of RRT performance with the hypothesis that RRTs led by intensivists-in-training would be better prepared to manage the scenarios than teams led by nurse practitioners. A set of 10 simulated scenarios was designed for the training and assessment of pediatric RRTs. Pediatric RRTs, comprising a pediatric intensive care unit (PICU) registered nurse and respiratory therapist, led by a PICU intensivist-in-training or a pediatric nurse practitioner, managed 7 simulated acutely decompensating patients. Two raters evaluated the scenario performances and psychometric analyses of the scenarios were performed. The teams readily managed scenarios such as supraventricular tachycardia and opioid overdose but had difficulty with more complicated scenarios such as aortic coarctation or head injury. The management of any particular scenario was reasonably predictive of overall team performance. The teams led by the PICU intensivists-in-training outperformed the teams led by the pediatric nurse practitioners. Simulation provides a method for RRTs to develop decision-making skills in managing decompensating pediatric patients. The multiple scenario assessment provided a moderately reliable team score. The greater scores achieved by PICU intensivist-in-training-led teams provides some evidence to support the validity of the assessment. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Rapid detection of biothreat agents based on cellular machinery.

    Energy Technology Data Exchange (ETDEWEB)

    Lane, Todd W.; Gantt, Richard W.

    2004-12-01

    This research addresses rapid and sensitive identification of biological agents in a complex background. We attempted to devise a method by which the specificity of the cellular transcriptional machinery could be used to detect and identify bacterial bio-terror agents in a background of other organisms. Bacterial cells contain RNA polymerases and transcription factors that transcribe genes into mRNA for translation into proteins. RNA polymerases in conjunction with transcription factors recognize regulatory elements (promoters) upstream of the gene. These promoters are, in many cases, recognized by the polymerase and transcription factor combinations of one species only. We have engineered a plasmid, for Escherichia coli, containing the virA promoter from the target species Shigella flexneri. This promoter was fused to a reporter gene Green Fluorescent Protein (GFP). In theory the indicator strain (carrying the plasmid) is mixed with the target strain and the two are lysed. The cellular machinery from both cells mixes and the GFP is produced. This report details the results of testing this system.

  20. The scope of application of incremental rapid prototyping methods in foundry engineering

    Directory of Open Access Journals (Sweden)

    M. Stankiewicz

    2010-01-01

    Full Text Available The article presents the scope of application of selected incremental Rapid Prototyping methods in the process of manufacturing casting models, casting moulds and casts. The Rapid Prototyping methods (SL, SLA, FDM, 3DP, JS are predominantly used for the production of models and model sets for casting moulds. The Rapid Tooling methods, such as: ZCast-3DP, ProMetalRCT and VoxelJet, enable the fabrication of casting moulds in the incremental process. The application of the RP methods in cast production makes it possible to speed up the prototype preparation process. This is particularly vital to elements of complex shapes. The time required for the manufacture of the model, the mould and the cast proper may vary from a few to several dozen hours.

  1. Population Set based Optimization Method

    Science.gov (United States)

    Manekar, Y.; Verma, H. K.

    2013-09-01

    In this paper an population set based optimization method is proposed for solving some benchmark functions and also to solve optimal power flow problem like `combined economic and emission dispatch problem (CEED)' with multiple objective functions. This algorithm has taken into consideration all the equality and inequality constraints. The improvement in system performance is based on reduction in cost of power generation and active power loss. The proposed algorithms have been compared with the other methods like GA, PSO etc reported in the literature. The results are impressive and encouraging. The study results show that the proposed method holds better solutions in CEED problems.

  2. Evaluation of two methods of rapid blood-glucose monitoring by unskilled personnel during surgery

    DEFF Research Database (Denmark)

    Madsbad, S; Adelhøj, B; Bigler, Dennis Richard

    1984-01-01

    The accuracy of two rapid methods of blood-glucose monitoring without (Haemo-glucotest 1-44) and with a reflectance meter (Hypocount B) was compared using a laboratory method. The assessment was carried out by personnel with no previous experience in measuring blood glucose. Eighty-five percent o...

  3. A rapid and convenient method for preparing salt-free (. gamma. -/sup 32/P)ATP

    Energy Technology Data Exchange (ETDEWEB)

    Palmer, J.L.; Avruch, J.

    1981-09-15

    (..gamma..-/sup 32/P)ATP is prepared by an existing enzymatic method that yields approximately 95% incorporation of /sup 32/P into ATP. A rapid and convenient method for purifying the (..gamma..-/sup 32/P)ATP which results in a product free of both salt and buffer is reported.

  4. High performance liquid chromatography method for rapid and accurate determination of homocysteine in plasma and serum

    DEFF Research Database (Denmark)

    Vester, Birte; Rasmussen, K

    1991-01-01

    Determination of homocysteine in plasma or serum for evaluation of cobalamin and folate deficiency is becoming an important diagnostic procedure. Accurate, rapid and low cost methods for measuring homocysteine are therefore required. We have improved an HPLC method and made it suitable for clinical...

  5. Evaluation of culture methods for rapid screening of swine faecal samples for Yersinia enterocolitica O : 3 biotype 4

    DEFF Research Database (Denmark)

    Hoorfar, Jeffrey; Holmvig, C.B.F.

    1999-01-01

    In two studies, seven different culture protocols were compared to test naturally contaminated faecal samples from pigs for isolation of Y. enterocolitica serotype O; 3/biotype 4( n = 70 and n = 79). Four of the protocols were based on the Nordic Committee on Food Analysis (NMKL protocols), while...... three protocols were based on a rapid and selective method (here called ITC protocols). The protocols differed mainly in time of pre-enrichment (1, 10 and 24 d) and enrichment (2, 10, 24 d) and the type of selective enrichment media (ITC vs. MRB). The sensitivity of the rapid ITC protocol (24% and 9...... indicate possibilities of shortening the culture methods by replacing most of the biochemical tests with an agglutination test based on a monoclonal antibody....

  6. Modified agar dilution method for rapid antibiotic susceptibility testing of anaerobic bacteria.

    Science.gov (United States)

    Hanson, C W; Martin, W J

    1978-01-01

    A simplified method has been developed for agar dilution antimicrobial susceptibility testing of anaerobic bacteria, designed to economize on time and money when only a few isolates need to be tested. The procedure is based on the principle of using filter paper disks as carriers of the antibiotic and 35- by 10-mm petri dishes which, when inoculated with the Steers replicator, can test up to four organisms per plate. The procedure was run in parallel with conventional agar dilution techniques and showed 95% agreement to within one dilution for all minimal inhibitory concentrations recorded on fresh anaerobic isolates from clinical specimens. The technique was further simplified by using commercially available antibiotic-containing disks, thereby alleviating the tedious and time-consuming procedure of preparing the disks. The data indicated that 48- to 72-h diffusion periods were sufficient to achieve a uniform concentration of the antibiotic in the petri plate and that the antibiotics were stable at room temperature for that period of time. In terms of applicability and relevance to the needs of the clinical microbiology laboratory, the modified agar dilution method for rapid antimicrobial susceptibility testing of individual anaerobic isolates was found to be superior to the broth dilution method since it was easier to read and required considerably less set up time. PMID:400819

  7. A simple and rapid cultural method for detection of Enterobacter sakazakii in environmental samples.

    Science.gov (United States)

    Guillaume-Gentil, O; Sonnard, V; Kandhai, M C; Marugg, J D; Joosten, H

    2005-01-01

    A method was developed to detect and identify Enterobacter sakazakii in environmental samples. The method is based on selective enrichment at 45+/-0.5 degrees C in lauryl sulfate tryptose broth supplemented with 0.5 M NaCl and 10 mg/liter vancomycin (mLST) for 22 to 24 h followed by streaking on tryptone soy agar with bile salts. When exposed to light during incubation at 37 degrees C, E. sakazakii produces yellow colonies within 24 h; identification was confirmed by testing for alpha-glucosidase activity and by using API 20E strips. All of the E. sakazakii strains tested (n = 99) were able to grow in mLST at 45+/-0.5 degrees C, whereas 35 of 39 strains of potential competitors, all belonging to the Enterobacteriaceae, were suppressed. A survey was carried out with 192 environmental samples from four different milk powder factories. Using this new protocol, E. sakazakii was isolated from almost 40% of the samples, whereas the reference procedure (enrichment in buffered peptone water, isolation on violet red bile glucose agar, and biochemical identification of randomly chosen colonies) only yielded 26% positive results. This selective method can be very useful for the rapid and reliable detection of E. sakazakii in environmental samples.

  8. Rapid, Simple, and Sensitive Spectrofluorimetric Method for the Estimation of Ganciclovir in Bulk and Pharmaceutical Formulations

    Directory of Open Access Journals (Sweden)

    Garima Balwani

    2013-01-01

    Full Text Available A new, simple, rapid, sensitive, accurate, and affordable spectrofluorimetric method was developed and validated for the estimation of ganciclovir in bulk as well as in marketed formulations. The method was based on measuring the native fluorescence of ganciclovir in 0.2 M hydrochloric acid buffer of pH 1.2 at 374 nm after excitation at 257 nm. The calibration graph was found to be rectilinear in the concentration range of 0.25–2.00 μg mL−1. The limit of quantification and limit of detection were found to be 0.029 μg mL−1 and 0.010 μg mL−1, respectively. The method was fully validated for various parameters according to ICH guidelines. The results demonstrated that the procedure is accurate, precise, and reproducible (relative standard deviation <2% and can be successfully applied for the determination of ganciclovir in its commercial capsules with average percentage recovery of 101.31 ± 0.90.

  9. A Rapid and Sensitive Method to Measure the Functional Activity of Shiga Toxins in Human Serum

    Directory of Open Access Journals (Sweden)

    Valentina Arfilli

    2015-11-01

    Full Text Available Shiga toxins (Stx have a definite role in the development of hemolytic uremic syndrome in children with hemorrhagic colitis caused by pathogenic Stx-producing Escherichia coli (STEC strains. The dramatic effects of these toxins on the microvasculature of different organs, particularly of the kidney, are well known, whereas there is no consensus on the mechanism by which Stx reach the endothelia of target organs and/or indirectly injure these body sites. We hereby describe a quick (4 h, radioactive, Raji cell-based method designed for the detection of Stx in human sera. The assay monitors the translation impairment induced by these powerful inhibitors of protein synthesis, which are identified properly by neutralizing their activity with specific monoclonal antibodies. By this method, we detected for the first time the functional activity of Stx in sera of STEC-infected patients during hemorrhagic colitis. Recent research has pointed to a dynamic process of Stx-induced renal intoxication in which concurrent and interactive steps are involved. Our rapid and specific method could be useful for studying the kinetics of Stx during the natural course of STEC infection and the interplay between Stx activity in serum and Stx presence in different blood fractions (neutrophils, monocytes, platelets, leukocyte-platelet aggregates, microvesicles, lipoproteins.

  10. AO–MW–PLS method applied to rapid quantification of teicoplanin with near-infrared spectroscopy

    Directory of Open Access Journals (Sweden)

    Jiemei Chen

    2017-01-01

    Full Text Available Teicoplanin (TCP is an important lipoglycopeptide antibiotic produced by fermenting Actinoplanes teichomyceticus. The change in TCP concentration is important to measure in the fermentation process. In this study, a reagent-free and rapid quantification method for TCP in the TCP–Tris–HCl mixture samples was developed using near-infrared (NIR spectroscopy by focusing our attention on the fermentation process for TCP. The absorbance optimization (AO partial least squares (PLS was proposed and integrated with the moving window (MW PLS, which is called AO–MW–PLS method, to select appropriate wavebands. A model set that includes various wavebands that were equivalent to the optimal AO–MW–PLS waveband was proposed based on statistical considerations. The public region of all equivalent wavebands was just one of the equivalent wavebands. The obtained public regions were 1540–1868nm for TCP and 1114–1310nm for Tris. The root-mean-square error and correlation coefficient for leave-one-out cross validation were 0.046mg mL−1 and 0.9998mg mL−1 for TCP, and 0.235mg mL−1 and 0.9986mg mL−1 for Tris, respectively. All the models achieved highly accurate prediction effects, and the selected wavebands provided valuable references for designing specialized spectrometers. This study provided a valuable reference for further application of the proposed methods to TCP fermentation broth and to other spectroscopic analysis fields.

  11. A Rapid and Sensitive Method to Measure the Functional Activity of Shiga Toxins in Human Serum

    Science.gov (United States)

    Arfilli, Valentina; Carnicelli, Domenica; Ardissino, Gianluigi; Torresani, Erminio; Scavia, Gaia; Brigotti, Maurizio

    2015-01-01

    Shiga toxins (Stx) have a definite role in the development of hemolytic uremic syndrome in children with hemorrhagic colitis caused by pathogenic Stx-producing Escherichia coli (STEC) strains. The dramatic effects of these toxins on the microvasculature of different organs, particularly of the kidney, are well known, whereas there is no consensus on the mechanism by which Stx reach the endothelia of target organs and/or indirectly injure these body sites. We hereby describe a quick (4 h), radioactive, Raji cell-based method designed for the detection of Stx in human sera. The assay monitors the translation impairment induced by these powerful inhibitors of protein synthesis, which are identified properly by neutralizing their activity with specific monoclonal antibodies. By this method, we detected for the first time the functional activity of Stx in sera of STEC-infected patients during hemorrhagic colitis. Recent research has pointed to a dynamic process of Stx-induced renal intoxication in which concurrent and interactive steps are involved. Our rapid and specific method could be useful for studying the kinetics of Stx during the natural course of STEC infection and the interplay between Stx activity in serum and Stx presence in different blood fractions (neutrophils, monocytes, platelets, leukocyte-platelet aggregates, microvesicles, lipoproteins). PMID:26556372

  12. Rapid and sensitive method for determination of withaferin-A in human plasma by HPLC.

    Science.gov (United States)

    Patial, Pankaj; Gota, Vikram

    2011-02-01

    To develop and validate a rapid and sensitive high-performance liquid chromatographic method for determination of withaferin-A in human plasma. Withaferin-A, the active molecule of a traditional Indian herb, has demonstrated several biological activities in preclinical models. A validated bioassay is not available for its pharmacokinetic evaluation. The chromatographic system used a reverse-phase C18 column with UV-visible detection at 225 nm. The mobile phase consisted of water and acetonitrile applied in a gradient flow. Withaferin-A was extracted by simple protein-precipitation technique. The calibration curve was linear in the concentration range of 0.05-1.6 µg/ml. The method has the desired sensitivity to detect the plasma concentration range of withaferin-A that is likely to show biological activity based on in vitro data. This is the first HPLC method ever described for the estimation of withaferin-A in human plasma which could be applied for pharmacokinetic studies.

  13. Comparing different methods for fast screening of microbiological quality of beach sand aimed at rapid-response remediation.

    Science.gov (United States)

    Testolin, Renan C; Almeida, Tito C M; Polette, Marcus; Branco, Joaquim O; Fischer, Larissa L; Niero, Guilherme; Poyer-Radetski, Gabriel; Silva, Valéria C; Somensi, Cleder A; Corrêa, Albertina X R; Corrêa, Rogério; Rörig, Leonardo R; Itokazu, Ana Gabriela; Férard, Jean-François; Cotelle, Sylvie; Radetski, Claudemir M

    2017-05-15

    There is scientific evidence that beach sands are a significant contributor to the pathogen load to which visitors are exposed. To develop beach quality guidelines all beach zones must be included in microbiological evaluations, but monitoring methods for beach sand quality are relatively longstanding, expensive, laborious and require moderate laboratory infrastructure. This paper aimed to evaluate the microorganism activity in different beach zones applying and comparing a classical method of membrane filtration (MF) with two colorimetric screening methods based on fluorescein (FDA) and tetrazolium (TTC) salt biotransformation to evaluate a new rapid and low-cost method for beach sand microbiological contamination assessments. The colorimetric results can help beach managers to evaluate rapidly and at low cost the microbiological quality of different beach zones in order to decide whether remedial actions need to be adopted to prevent exposure of the public to microbes due to beach sand and/or water contamination. Copyright © 2017. Published by Elsevier Ltd.

  14. Use of predictive models and rapid methods to nowcast bacteria levels at coastal beaches

    Science.gov (United States)

    Francy, Donna S.

    2009-01-01

    The need for rapid assessments of recreational water quality to better protect public health is well accepted throughout the research and regulatory communities. Rapid analytical methods, such as quantitative polymerase chain reaction (qPCR) and immunomagnetic separation/adenosine triphosphate (ATP) analysis, are being tested but are not yet ready for widespread use.Another solution is the use of predictive models, wherein variable(s) that are easily and quickly measured are surrogates for concentrations of fecal-indicator bacteria. Rainfall-based alerts, the simplest type of model, have been used by several communities for a number of years. Deterministic models use mathematical representations of the processes that affect bacteria concentrations; this type of model is being used for beach-closure decisions at one location in the USA. Multivariable statistical models are being developed and tested in many areas of the USA; however, they are only used in three areas of the Great Lakes to aid in notifications of beach advisories or closings. These “operational” statistical models can result in more accurate assessments of recreational water quality than use of the previous day's Escherichia coli (E. coli)concentration as determined by traditional culture methods. The Ohio Nowcast, at Huntington Beach, Bay Village, Ohio, is described in this paper as an example of an operational statistical model. Because predictive modeling is a dynamic process, water-resource managers continue to collect additional data to improve the predictive ability of the nowcast and expand the nowcast to other Ohio beaches and a recreational river. Although predictive models have been shown to work well at some beaches and are becoming more widely accepted, implementation in many areas is limited by funding, lack of coordinated technical leadership, and lack of supporting epidemiological data.

  15. Rapid radiometric methods to detect and differentiate Mycobacterium tuberculosis/M. bovis from other mycobacterial species

    Energy Technology Data Exchange (ETDEWEB)

    Siddiqi, S.H.; Hwangbo, C.C.; Silcox, V.; Good, R.C.; Snider, D.E. Jr.; Middlebrook, G.

    1984-10-01

    Rapid methods for the differentiation of Mycobacterium tuberculosis/M. bovis (TB complex) from other mycobacteria (MOTT bacilli) were developed and evaluated in a three-phase study. In the first phase, techniques for identification of Mycobacterium species were developed by using radiometric technology and BACTEC Middlebrook 7H12 liquid medium. Based on /sup 14/CO/sub 2/ evolution, characteristic growth patterns were established for 13 commonly encountered mycobacterial species. Mycobacteria belonging to the TB complex were differentiated from other mycobacteria by cellular morphology and rate of /sup 14/CO/sub 2/ evolution. For further differentiation, radiometric tests for niacin production and inhibition by Q-nitro-alpha-acetyl amino-beta-hydroxy-propiophenone (NAP) were developed. In the second phase, 100 coded specimens on Lowenstein-Jensen medium were identified as members of the TB complex, MOTT bacilli, bacteria other than mycobacteria, or ''no viable organisms'' within 3 to 12 (average 6.4) days of receipt from the Centers for Disease Control. Isolation and identification of mycobacteria from 20 simulated sputum specimens were carried out in phase III. Out of 20 sputum specimens, 16 contained culturable mycobacteria, and all of the positives were detected by the BACTEC method in an average of 7.3 days. The positive mycobacterial cultures were isolated and identified as TB complex or MOTT bacilli in an average of 12.8 days. The radiometric NAP test was found to be highly sensitive and specific for a rapid identification of TB complex, whereas the radiometric niacin test was found to have some inherent problems. Radiometric BACTEC and conventional methodologies were in complete agreement in Phase II as well as in Phase III.

  16. A Rapid Method for Quantifying Viable Mycobacterium avium subsp. paratuberculosis in Cellular Infection Assays

    Science.gov (United States)

    Pooley, Hannah B.; de Silva, Kumudika; Purdie, Auriol C.; Begg, Douglas J.; Whittington, Richard J.

    2016-01-01

    ABSTRACT Determining the viability of bacteria is a key outcome of in vitro cellular infection assays. Currently, this is done by culture, which is problematic for fastidious slow-growing bacteria such as Mycobacterium avium subsp. paratuberculosis, where it can take up to 4 months to confirm growth. This study aimed to identify an assay that can rapidly quantify the number of viable M. avium subsp. paratuberculosis cells in a cellular sample. Three commercially available bacterial viability assays along with a modified liquid culture method coupled with high-throughput quantitative PCR growth detection were assessed. Criteria for assessment included the ability of each assay to differentiate live and dead M. avium subsp. paratuberculosis organisms and their accuracy at low bacterial concentrations. Using the culture-based method, M. avium subsp. paratuberculosis growth was reliably detected and quantified within 2 weeks. There was a strong linear association between the 2-week growth rate and the initial inoculum concentration. The number of viable M. avium subsp. paratuberculosis cells in an unknown sample was quantified based on the growth rate, by using growth standards. In contrast, none of the commercially available viability assays were suitable for use with samples from in vitro cellular infection assays. IMPORTANCE Rapid quantification of the viability of Mycobacterium avium subsp. paratuberculosis in samples from in vitro cellular infection assays is important, as it allows these assays to be carried out on a large scale. In vitro cellular infection assays can function as a preliminary screening tool, for vaccine development or antimicrobial screening, and also to extend findings derived from experimental animal trials. Currently, by using culture, it takes up to 4 months to obtain quantifiable results regarding M. avium subsp. paratuberculosis viability after an in vitro infection assay; however, with the quantitative PCR and liquid culture method

  17. Microfluidic Immunoassays as Rapid Saliva-Based Clinical Diagnostics

    National Research Council Canada - National Science Library

    Amy E. Herr; Anson V. Hatch; Daniel J. Throckmorton; Huu M. Tran; James S. Brennan; William V. Giannobile; Anup K. Singh

    2007-01-01

    .... Here we report on a clinical POC diagnostic that enables rapid quantitation of an oral disease biomarker in human saliva by using a monolithic disposable cartridge designed to operate in a compact analytical instrument...

  18. Development of a fluorescence in situ hybridization (FISH) method for rapid detection of Ulva prolifera

    Science.gov (United States)

    Zhang, Qing-Chun; Liu, Qing; Kang, Zhen-Jun; Yu, Ren-Cheng; Yan, Tian; Zhou, Ming-Jiang

    2015-09-01

    Large-scale green tides have occurred consecutively since 2007 in the Yellow Sea (YS), China. The dominant causative species of the green tides has been identified as Ulva prolifera. The origin of green tides in the YS has been traced back to the Subei Shoal based on the results of remote-sensing, numerical simulations and field investigations. However, it is difficult to study the early development of green tides in the Subei Shoal because of the mixture of multiple green algae and the morphological diversity of U. prolifera when under variable environmental conditions. In this study, a rapid and accurate fluorescence in situ hybridization (FISH) method was developed to detect U. prolifera from the community of green algae targeting the 5S rDNA spacer region of U. prolifera. Two specific probes, 5S-1 and 5S-2, were designed based on the sequences of the 5S rDNA spacer regions of U. prolifera, Ulva linza and Ulva flexuosa. Specificity of the FISH method was tested using the six species of green algae commonly occurring in the Subei Shoal, including U. prolifera, U. linza, U. flexuosa, Ulva compressa, Ulva pertusa and Blidingia sp. The results showed that only U. prolifera could be labeled with both probes. Probe 5S-1, which showed a much higher labeling efficiency on U. prolifera, was ultimately selected as the probe for the FISH detection. The sample preparation method was optimized, particularly for the mature green algae, by the addition of cellulase and proteinase K in the pre-hybridization solution. Labeling efficiency with the probe 5S-1 reached 96% on average under the optimized conditions. The successful development of the FISH method has been applied to qualitative and quantitative analysis of field samples collected from the YS, and the results indicate a potential use in future green algae studies.

  19. A method for rapid measurement of laser ablation rate of hard dental tissue

    Science.gov (United States)

    Perhavec, T.; Gorkič, A.; Bračun, D.; Diaci, J.

    2009-06-01

    The aim of the study reported here is the development of a new method which allows rapid and accurate in-vitro measurements of three-dimensional (3D) shape of laser ablated craters in hard dental tissues and the determination of crater volume, ablation rate and speed. The method is based on the optical triangulation principle. A laser sheet projector illuminates the surface of a tooth, mounted on a linear translation stage. As the tooth is moved by the translation stage a fast digital video camera captures series of images of the illuminated surface. The images are analyzed to determine a 3D model of the surface. Custom software is employed to analyze the 3D model and to determine the volume of the ablated craters. Key characteristics of the method are discussed as well as some practical aspects pertinent to its use. The method has been employed in an in-vitro study to examine the ablation rates and speeds of the two main laser types currently employed in dentistry, Er:YAG and Er,Cr:YSGG. Ten samples of extracted human molar teeth were irradiated with laser pulse energies from 80 mJ to the maximum available energy (970 mJ with the Er:YAG, and 260 mJ with the Er,Cr:YSGG). About 2000 images of each ablated tooth surface have been acquired along a translation range of 10 mm, taking about 10 s and providing close to 1 million surface measurement points. Volumes of 170 ablated craters (half of them in dentine and the other half in enamel) were determined from this data and used to examine the ablated volume per pulse energy and ablation speed. The results show that, under the same conditions, the ablated volume per pulse energy achieved by the Er:YAG laser exceeds that of the Er,Cr:YSGG laser in almost all regimes for dentine and enamel. The maximum Er:YAG laser ablation speeds (1.2 mm 3/s in dentine and 0.7 mm 3/s in enamel) exceed those obtained by the Er,Cr:YSGG laser (0.39 mm 3/s in dentine and 0.12 mm 3/s in enamel). Since the presented method proves to be easy to

  20. Rapid high temperature field test method for evaluation of geothermal calcite scale inhibitors

    Energy Technology Data Exchange (ETDEWEB)

    Asperger, R.G.

    1982-08-01

    A test method is described which allows the rapid field testing of calcite scale inhibitors in high- temperature geothermal brines. Five commercial formulations, chosen on the basis of laboratory screening tests, were tested in brines with low total dissolved solids at ca 500 F. Four were found to be effective; of these, 2 were found to be capable of removing recently deposited scale. One chemical was tested in the full-flow brine line for 6 wks. It was shown to stop a severe surface scaling problem at the well's control valve, thus proving the viability of the rapid test method. (12 refs.)

  1. Evidence-based medicine in rapidly changing technologies

    DEFF Research Database (Denmark)

    Schroeder, T V

    2008-01-01

    Evidence-based medicine (EBM) is not a randomised controlled trial (RCT), but EBM seeks to apply evidence gained from scientific methods - which could be RCT - to daily medical practice. Any surgical treatment reflects a certain development technically as well as skills based. The procedure may....... On the other hand, if started too late there is a chance that data may be lost because the technology has already been introduced into the daily clinics and physicians may be unwilling to recruit patients. Or the opposite, that the technique may have been rejected without a proper trial. In this situation...... it has been suggested to perform a so called tracker trial. In such trials protocols are more flexible without prefixed sample size and will require repeated interim analyses. Often, it will be relevant to supplement the clinical trials with data from large clinical databases - in particular when long...

  2. Method for gesture based modeling

    DEFF Research Database (Denmark)

    2006-01-01

    A computer program based method is described for creating models using gestures. On an input device, such as an electronic whiteboard, a user draws a gesture which is recognized by a computer program and interpreted relative to a predetermined meta-model. Based on the interpretation, an algorithm...... is assigned to the gesture drawn by the user. The executed algorithm may, for example, consist in creating a new model element, modifying an existing model element, or deleting an existing model element....

  3. A simple and rapid visual method for the determination of ammonia nitrogen in environmental waters using thymol

    Energy Technology Data Exchange (ETDEWEB)

    Okumura, M.; Fujinaga, K.; Seike, Y.; Honda, S. [Dept. of Material Science, Interdisciplinary Faculty of Science and Engineering, Shimane University, Matsue (Japan)

    1999-11-01

    Simple visual and spectrophotometric methods for the determination of ammonia nitrogen in water are proposed, based on the color development of indothymol blue formed between ammonia and thymol. The color development was accelerated by nitroprusside to complete in 3 min. This color development is remarkably rapid compared with that of the other conventional methods with indothymol blue and indophenol blue. The concentration range of ammonia nitrogen spectrophotometrically determined was 0.04-1.2 mg/L NH{sub 4}-N. The absorbance per 1 {mu}g NH{sub 4}-N was 0.0215 (molar absorptivity = 1.51 x 10{sup 4}) at 690 nm. The visual method not using any instrument as an in situ method in field works was developed based on the optimum conditions for the established spectrophotometric method. This visual method was successfully applied to the determination of ammonia nitrogen in environmental waters. (orig.)

  4. MacroEvoLution: A New Method for the Rapid Generation of Novel Scaffold-Diverse Macrocyclic Libraries.

    Science.gov (United States)

    Saupe, Jörn; Kunz, Oliver; Haustedt, Lars Ole; Jakupovic, Sven; Mang, Christian

    2017-09-04

    Macrocycles are a structural class bearing great promise for future challenges in medicinal chemistry. Nevertheless, there are few flexible approaches for the rapid generation of structurally diverse macrocyclic compound collections. Here, an efficient method for the generation of novel macrocyclic peptide-based scaffolds is reported. The process, named here as "MacroEvoLution", is based on a cyclization screening approach that gives reliable access to novel macrocyclic architectures. Classification of building blocks into specific pools ensures that scaffolds with orthogonally addressable functionalities are generated, which can easily be used for the generation of structurally diverse compound libraries. The method grants rapid access to novel scaffolds with scalable synthesis (multi gram scale) and the introduction of further diversity at a late stage. Despite being developed for peptidic systems, the approach can easily be extended for the synthesis of systems with a decreased peptidic character. © 2017 The Authors. Published by Wiley-VCH Verlag GmbH & Co. KGaA.

  5. MacroEvoLution: A New Method for the Rapid Generation of Novel Scaffold‐Diverse Macrocyclic Libraries

    Science.gov (United States)

    Saupe, Jörn; Kunz, Oliver; Haustedt, Lars Ole; Jakupovic, Sven

    2017-01-01

    Abstract Macrocycles are a structural class bearing great promise for future challenges in medicinal chemistry. Nevertheless, there are few flexible approaches for the rapid generation of structurally diverse macrocyclic compound collections. Here, an efficient method for the generation of novel macrocyclic peptide‐based scaffolds is reported. The process, named here as “MacroEvoLution”, is based on a cyclization screening approach that gives reliable access to novel macrocyclic architectures. Classification of building blocks into specific pools ensures that scaffolds with orthogonally addressable functionalities are generated, which can easily be used for the generation of structurally diverse compound libraries. The method grants rapid access to novel scaffolds with scalable synthesis (multi gram scale) and the introduction of further diversity at a late stage. Despite being developed for peptidic systems, the approach can easily be extended for the synthesis of systems with a decreased peptidic character. PMID:28715083

  6. TranScreen-N: Method for rapid screening of trans-ungual drug delivery enhancers.

    Science.gov (United States)

    Murthy, S Narasimha; Vaka, Siva Ram Kiran; Sammeta, Srinivasa Murthy; Nair, Anroop B

    2009-11-01

    Topical monotherapy of nail diseases such as onychomycosis and nail psoriasis has been less successful due to poor permeability of the human nail plate to topically administered drugs. Chemical enhancers are utilized to improve the drug delivery across the nail plate. Choosing the most effective chemical enhancers for the given drug and formulation is highly critical in determining the efficacy of topical therapy of nail diseases. Screening the large pool of enhancers using currently followed diffusion cell experiments would be tedious and expensive. The main objective of this study is to develop TranScreen-N, a high throughput method of screening trans-ungual drug permeation enhancers. It is a rapid microwell plate based method which involves two different treatment procedures; the simultaneous exposure treatment and the sequential exposure treatment. In the present study, several chemicals were evaluated by TranScreen-N and by diffusion studies in the Franz diffusion cell (FDC). Good agreement of in vitro drug delivery data with TranScreen-N data provided validity to the screening technique. In TranScreen-N technique, the enhancers can be grouped according to whether they need to be applied before or simultaneously with drugs (or by either procedures) to enhance the drug delivery across the nail plate. TranScreen-N technique can significantly reduce the cost and duration required to screen trans-ungual drug delivery enhancers. (c) 2009 Wiley-Liss, Inc. and the American Pharmacists Association

  7. The rapid interphase chromosome assay (RICA implementation: comparison with other PCC methods

    Directory of Open Access Journals (Sweden)

    Sommer Sylwester

    2015-12-01

    Full Text Available A report is presented on the advantages of the rapid interphase chromosome assay (RICA and the difficulties that may be met while implementing this method for application in biological dosimetry. The RICA test can be applied on unstimulated human lymphocytes; this is an advantage in comparison with the dicentric chromosomes or micronucleus tests. In the former two tests, stimulated lymphocytes are examined and hence, 48 h more are needed to obtain cells traversing the cell cycle. Due to the use of unstimulated nondividing cells, higher numbers of cells are available for RICA analysis than for dicentric chromosomes or micronuclei tests. Moreover, the method can be applied after exposure to ionizing radiation doses in excess of 5 Gy. Such doses cause a significant cell cycle delay or result in the loss of G2 phase and mitotic cells because of apoptosis. Therefore, the traditional biodosimetry based on the evaluation of the incidence of damage to chromosomes is very difficult to carry out. This is due to the lack of an adequate number of mitotic cells for analysis. RICA is free of this disadvantage. An automatic microscope can be used to retrieve cell images; automatic image analysis can also be used.

  8. A rapid and sensitive spectrophotometric method for the determination of benzoyl peroxide in wheat flour samples

    Directory of Open Access Journals (Sweden)

    Kraingkrai Ponhong

    2015-12-01

    Full Text Available A simple, rapid, and sensitive spectrophotometric method for the determination of benzoyl peroxide (BPO in wheat flour samples was developed. The detection principle is based on BPO reacted with 2,2′-azino-bis(3-ethylbenzothiazoline-6-sulfonic acid (ABTS to obtain a blue-green colored product that was detected at 415 nm by spectrophotometry. The effect of factors influencing the color reaction was investigated. Under the selected conditions, the linear range for quantification of BPO was observed between 0.2–1.0 mg L−1 with r2 = 0.998. The limit of detection (LOD was 0.025 mg L−1. The developed method obtained superior precision (relative standard deviation < 2% using 11 repeatability at 0.2 mg L−1, 0.6 mg L−1, and 0.8 mg L−1. The proposed methodology was successfully applied to determine BPO in wheat flour samples.

  9. Entropy-based benchmarking methods

    NARCIS (Netherlands)

    Temurshoev, Umed

    2012-01-01

    We argue that benchmarking sign-volatile series should be based on the principle of movement and sign preservation, which states that a bench-marked series should reproduce the movement and signs in the original series. We show that the widely used variants of Denton (1971) method and the growth

  10. Novel, rapid optical immunoassay technique for detection of group A streptococci from pharyngeal specimens: comparison with standard culture methods.

    OpenAIRE

    Harbeck, R. J.; Teague, J; Crossen, G R; Maul, D M; Childers, P L

    1993-01-01

    A novel immunoassay system based on the changes in the reflection of light, termed an optical immunoassay (OIA), was utilized to directly detect group A streptococcal (GAS) carbohydrate antigen from clinical specimens. In two studies, a total of 1,275 throat swabs were tested for the presence of this antigen with the Strep A OIA rapid detection system and the results were compared with those of standard culture methods. In both studies, the Strep A OIA yielded more positive results than plati...

  11. Hydrodynamic Voltammetry as a Rapid and Simple Method for Evaluating Soil Enzyme Activities

    Directory of Open Access Journals (Sweden)

    Kazuto Sazawa

    2015-03-01

    Full Text Available Soil enzymes play essential roles in catalyzing reactions necessary for nutrient cycling in the biosphere. They are also sensitive indicators of ecosystem stress, therefore their evaluation is very important in assessing soil health and quality. The standard soil enzyme assay method based on spectroscopic detection is a complicated operation that requires the removal of soil particles. The purpose of this study was to develop a new soil enzyme assay based on hydrodynamic electrochemical detection using a rotating disk electrode in a microliter droplet. The activities of enzymes were determined by measuring the electrochemical oxidation of p-aminophenol (PAP, following the enzymatic conversion of substrate-conjugated PAP. The calibration curves of β-galactosidase (β-gal, β-glucosidase (β-glu and acid phosphatase (AcP showed good linear correlation after being spiked in soils using chronoamperometry. We also performed electrochemical detection using real soils. Hydrodynamic chronoamperometry can be used to assess the AcP in soils, with a detection time of only 90 s. Linear sweep voltammetry was used to measure the amount of PAP released from β-gal and β-glu by enzymatic reaction after 60 min. For the assessment of soil enzymes, the results of hydrodynamic voltammetry assay compared favorably to those using a standard assay procedure, but this new procedure is more user-friendly, rapid and simple.

  12. Furuncular myiasis: a simple and rapid method for extraction of intact Dermatobia hominis larvae.

    Science.gov (United States)

    Boggild, Andrea K; Keystone, Jay S; Kain, Kevin C

    2002-08-01

    We report a case of furuncular myiasis complicated by Staphylococcus aureus infection and beta-hemolytic streptococcal cellulitis. The Dermatobia hominis larva that caused this lesion could not be extracted using standard methods, including suffocation and application of lateral pressure, and surgery was contraindicated because of cellulitis. The botfly maggot was completely and rapidly extracted with an inexpensive, disposable, commercial venom extractor.

  13. Collision-induced fragmentation accurate mass spectrometric analysis methods to rapidly characterize phytochemicals in plant extracts

    Science.gov (United States)

    The rapid advances in analytical chromatography equipment have made the reliable and reproducible measurement of a wide range of plant chemical components possible. Full chemical characterization of a given plant material is possible with the new mass spectrometers currently available. New methods a...

  14. Collaborative validation of a rapid method for efficient virus concentration in bottled water

    DEFF Research Database (Denmark)

    Schultz, Anna Charlotte; Perelle, Sylvie; Di Pasquale, Simona

    2011-01-01

    Enteric viruses, including norovirus (NoV) and hepatitis A virus (HAV), have emerged as a major cause of waterborne outbreaks worldwide. Due to their low infectious doses and low concentrations in water samples, an efficient and rapid virus concentration method is required for routine control. Th...

  15. A Rapid Method for Measuring Strontium-90 Activity in Crops in China

    Directory of Open Access Journals (Sweden)

    Pan Lingjing Pan

    2017-01-01

    Full Text Available A rapid method for measuring Sr-90 activity in crop ashes is presented. Liquid scintillation counting, combined with ion exchange columns 4‘, 4“(5“-di-t-butylcyclohexane-18-crown-6, is used to determine the activity of Sr-90 in crops. The yields of chemical procedure are quantified using gravimetric analysis. The conventional method that uses ion-exchange resin with HDEHP could not completely remove all the bismuth when comparatively large lead and bismuth exist in the samples. This is overcome by the rapid method. The chemical yield of this method is about 60% and the MDA for Sr-90 is found to be 2:32 Bq/kg. The whole procedure together with using spectrum analysis to determine the activity only takes about one day, which is really a large improvement compared with the conventional method. A modified conventional method is also described here to verify the value of the rapid one. These two methods can meet di_erent needs of daily monitoring and emergency situation.

  16. A Rapid Method for Measuring Strontium-90 Activity in Crops in China

    Science.gov (United States)

    Pan, Lingjing Pan; Yu, Guobing; Wen, Deyun; Chen, Zhi; Sheng, Liusi; Liu, Chung-King; Xu, X. George

    2017-09-01

    A rapid method for measuring Sr-90 activity in crop ashes is presented. Liquid scintillation counting, combined with ion exchange columns 4`, 4"(5")-di-t-butylcyclohexane-18-crown-6, is used to determine the activity of Sr-90 in crops. The yields of chemical procedure are quantified using gravimetric analysis. The conventional method that uses ion-exchange resin with HDEHP could not completely remove all the bismuth when comparatively large lead and bismuth exist in the samples. This is overcome by the rapid method. The chemical yield of this method is about 60% and the MDA for Sr-90 is found to be 2:32 Bq/kg. The whole procedure together with using spectrum analysis to determine the activity only takes about one day, which is really a large improvement compared with the conventional method. A modified conventional method is also described here to verify the value of the rapid one. These two methods can meet di_erent needs of daily monitoring and emergency situation.

  17. A Simple and Rapid Identification Method for Mycobacterium bovis BCG with Loop-Mediated Isothermal Amplification.

    Directory of Open Access Journals (Sweden)

    Yuji Kouzaki

    Full Text Available Bacillus Calmette-Guérin (BCG is widely used as a live attenuated vaccine against Mycobacterium tuberculosis and is an agent for standard prophylaxis against the recurrence of bladder cancer. Unfortunately, it can cause severe infectious diseases, especially in immunocompromised patients, and the ability to immediately distinguish BCG from other M. tuberculosis complexes is therefore important. In this study, we developed a simple and easy-to-perform identification procedure using loop-mediated amplification (LAMP to detect deletions within the region of difference, which is deleted specifically in all M. bovis BCG strains. Reactions were performed at 64 °C for 30 min and successful targeted gene amplifications were detected by real-time turbidity using a turbidimeter and visual inspection of color change. The assay had an equivalent detection limit of 1.0 pg of genomic DNA using a turbidimeter whereas it was 10 pg with visual inspection, and it showed specificity against 49 strains of 44 pathogens, including M. tuberculosis complex. The expected LAMP products were confirmed through identical melting curves in real-time LAMP procedures. We employed the Procedure for Ultra Rapid Extraction (PURE kit to isolate mycobacterial DNA and found that the highest sensitivity limit with a minimum total cell count of mycobacterium (including DNA purification with PURE was up to 1 × 10(3 cells/reaction, based on color changes under natural light with FDA reagents. The detection limit of this procedure when applied to artificial serum, urine, cerebrospinal fluid, and bronchoalveolar lavage fluid samples was also about 1 × 10(3 cells/reaction. Therefore, this substitute method using conventional culture or clinical specimens followed by LAMP combined with PURE could be a powerful tool to enable the rapid identification of M. bovis BCG as point-of-care testing. It is suitable for practical use not only in resource-limited situations, but also in any

  18. Rapid thyroid dysfunction screening based on serum surface-enhanced Raman scattering and multivariate statistical analysis

    Science.gov (United States)

    Tian, Dayong; Lü, Guodong; Zhai, Zhengang; Du, Guoli; Mo, Jiaqing; Lü, Xiaoyi

    2018-01-01

    In this paper, serum surface-enhanced Raman scattering and multivariate statistical analysis are used to investigate a rapid screening technique for thyroid function diseases. At present, the detection of thyroid function has become increasingly important, and it is urgently necessary to develop a rapid and portable method for the detection of thyroid function. Our experimental results show that, by using the Silmeco-based enhanced Raman signal, the signal strength greatly increases and the characteristic peak appears obviously. It is also observed that the Raman spectra of normal and anomalous thyroid function human serum are significantly different. Principal component analysis (PCA) combined with linear discriminant analysis (LDA) was used to diagnose thyroid dysfunction, and the diagnostic accuracy was 87.4%. The use of serum surface-enhanced Raman scattering technology combined with PCA–LDA shows good diagnostic performance for the rapid detection of thyroid function. By means of Raman technology, it is expected that a portable device for the rapid detection of thyroid function will be developed.

  19. Rapid method for determination of carbonyl groups in lignin compounds by headspace gas chromatography.

    Science.gov (United States)

    Li, Jing; Hu, Hui-Chao; Chai, Xin-Sheng

    2015-07-24

    The paper reports on a novel method for rapid determination of carbonyl in lignins by headspace gas chromatography (HS-GC). The method involves the quantitative carbonyl reduction for aldehydes in 2min at room temperature or for acetones in 30min at 80°C by sodium borohydride solution in a closed headspace sample vial. After the reaction, the solution was acidified by injecting sulfuric acid solution and the hydrogen released to the headspace was determined by GC using thermal-conductivity detector. The results showed that with the addition of SiO2 powder, the reduction reaction of carbonyl groups can be greatly facilitated. The method has a good measurement precision (RSD<7.74%) and accuracy (relative error <10% compared with a reference method) in the carbonyl quantification. It is suitable to be used for rapid determination of carbonyl content in lignin and related materials. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Apparatus and method for rapid separation and detection of hydrocarbon fractions in a fluid stream

    Science.gov (United States)

    Sluder, Charles S.; Storey, John M.; Lewis, Sr., Samuel A.

    2013-01-22

    An apparatus and method for rapid fractionation of hydrocarbon phases in a sample fluid stream are disclosed. Examples of the disclosed apparatus and method include an assembly of elements in fluid communication with one another including one or more valves and at least one sorbent chamber for removing certain classifications of hydrocarbons and detecting the remaining fractions using a detector. The respective ratios of hydrocarbons are determined by comparison with a non separated fluid stream.

  1. A convenient and rapid method for genetic transformation of E. coli with plasmids.

    Science.gov (United States)

    Chen, X; Guo, P; Xie, Z; Shen, P

    2001-12-01

    A convenient and rapid method for the genetic transformation of Escherichia coli with plasmids is proposed. By mixing the recipient cells and plasmid DNA and spreading them directly on selective medium plates containing Ca2+, the so-called 'plate transformation' could achieve almost the same transformation efficiency as the classical transformation method with calcium. The whole protocol takes only about 2 min, its simplicity compared favorably, not only to the usual protocol, but also to all other documented modifications.

  2. Rapid qualitative research methods during complex health emergencies: A systematic review of the literature.

    Science.gov (United States)

    Johnson, Ginger A; Vindrola-Padros, Cecilia

    2017-09-01

    The 2013-2016 Ebola outbreak in West Africa highlighted both the successes and limitations of social science contributions to emergency response operations. An important limitation was the rapid and effective communication of study findings. A systematic review was carried out to explore how rapid qualitative methods have been used during global heath emergencies to understand which methods are commonly used, how they are applied, and the difficulties faced by social science researchers in the field. We also asses their value and benefit for health emergencies. The review findings are used to propose recommendations for qualitative research in this context. Peer-reviewed articles and grey literature were identified through six online databases. An initial search was carried out in July 2016 and updated in February 2017. The PRISMA checklist was used to guide the reporting of methods and findings. The articles were assessed for quality using the MMAT and AACODS checklist. From an initial search yielding 1444 articles, 22 articles met the criteria for inclusion. Thirteen of the articles were qualitative studies and nine used a mixed-methods design. The purpose of the rapid studies included: the identification of causes of the outbreak, and assessment of infrastructure, control strategies, health needs and health facility use. The studies varied in duration (from 4 days to 1 month). The main limitations identified by the authors were: the low quality of the collected data, small sample sizes, and little time for cross-checking facts with other data sources to reduce bias. Rapid qualitative methods were seen as beneficial in highlighting context-specific issues that need to be addressed locally, population-level behaviors influencing health service use, and organizational challenges in response planning and implementation. Recommendations for carrying out rapid qualitative research in this context included the early designation of community leaders as a point of

  3. Rapid Transfer Alignment of MEMS SINS Based on Adaptive Incremental Kalman Filter.

    Science.gov (United States)

    Chu, Hairong; Sun, Tingting; Zhang, Baiqiang; Zhang, Hongwei; Chen, Yang

    2017-01-14

    In airborne MEMS SINS transfer alignment, the error of MEMS IMU is highly environment-dependent and the parameters of the system model are also uncertain, which may lead to large error and bad convergence of the Kalman filter. In order to solve this problem, an improved adaptive incremental Kalman filter (AIKF) algorithm is proposed. First, the model of SINS transfer alignment is defined based on the "Velocity and Attitude" matching method. Then the detailed algorithm progress of AIKF and its recurrence formulas are presented. The performance and calculation amount of AKF and AIKF are also compared. Finally, a simulation test is designed to verify the accuracy and the rapidity of the AIKF algorithm by comparing it with KF and AKF. The results show that the AIKF algorithm has better estimation accuracy and shorter convergence time, especially for the bias of the gyroscope and the accelerometer, which can meet the accuracy and rapidity requirement of transfer alignment.

  4. Low-cost rapid prototyping of flexible plastic paper based microfluidic devices

    KAUST Repository

    Fan, Yiqiang

    2013-04-01

    This research presents a novel rapid prototyping method for paper-based flexible microfluidic devices. The microchannels were fabricated using laser ablation on a piece of plastic paper (permanent paper), the dimensions of the microchannels was carefully studied for various laser powers and scanning speeds. After laser ablation of the microchannels on the plastic paper, a transparent poly (methyl methacrylate)(PMMA) film was thermally bonded to the plastic paper to enclose the channels. After connection of tubing, the device was ready to use. An example microfluidic device (droplet generator) was also fabricated using this technique. Due to the flexibility of the fabricated device, this technique can be used to fabricate 3D microfluidic devices. The fabrication process was simple and rapid without any requirement of cleanroom facilities. © 2013 IEEE.

  5. Rapid and Highly Sensitive Detection of Lead Ions in Drinking Water Based on a Strip Immunosensor

    Directory of Open Access Journals (Sweden)

    Chuanlai Xu

    2013-03-01

    Full Text Available In this study, we have first developed a rapid and sensitive strip immunosensor based on two heterogeneously-sized gold nanoparticles (Au NPs probes for the detection of trace lead ions in drinking water. The sensitivity was 4-fold higher than that of the conventional LFA under the optimized conditions. The visual limit of detection (LOD of the amplified method for qualitative detection lead ions was 2 ng/mL and the LOD for semi-quantitative detection could go down to 0.19 ng/mL using a scanning reader. The method suffered from no interference from other metal ions and could be used to detect trace lead ions in drinking water without sample enrichment. The recovery of the test samples ranged from 96% to 103%. As the detection method could be accomplished within 15 min, this method could be used as a potential tool for preliminary monitoring of lead contamination in drinking water.

  6. Rapid and Economic Access to Some NSAIDS-Based Bioactive Heterocycles

    Directory of Open Access Journals (Sweden)

    A. V. Chavan

    2013-01-01

    Full Text Available The use of microwave energy for the synthesis is considered as one of the alternate strategies. The present work includes the synthesis of some newer 2,5-disubstituted-1,3,4-oxadiazole analogues using both conventional and alternate rapid methods.The conventional method involves the synthesis of the target molecules by using cyclodehydrating agent like POCl3, while the other method consists of using some catalytic reagents like PbO2. Also, the short reaction time provided by microwave synthesis makes it ideal for the reaction. Hence, this project describes an efficient and operationally simple method for the microwave-assisted synthesis of some bioactive heterocycles based on NSAIDs.

  7. Rapid and highly sensitive detection of lead ions in drinking water based on a strip immunosensor.

    Science.gov (United States)

    Kuang, Hua; Xing, Changrui; Hao, Changlong; Liu, Liqiang; Wang, Libing; Xu, Chuanlai

    2013-03-28

    In this study, we have first developed a rapid and sensitive strip immunosensor based on two heterogeneously-sized gold nanoparticles (Au NPs) probes for the detection of trace lead ions in drinking water. The sensitivity was 4-fold higher than that of the conventional LFA under the optimized conditions. The visual limit of detection (LOD) of the amplified method for qualitative detection lead ions was 2 ng/mL and the LOD for semi-quantitative detection could go down to 0.19 ng/mL using a scanning reader. The method suffered from no interference from other metal ions and could be used to detect trace lead ions in drinking water without sample enrichment. The recovery of the test samples ranged from 96% to 103%. As the detection method could be accomplished within 15 min, this method could be used as a potential tool for preliminary monitoring of lead contamination in drinking water.

  8. Seed oil polyphenols: rapid and sensitive extraction method and high resolution-mass spectrometry identification.

    Science.gov (United States)

    Koubaa, Mohamed; Mhemdi, Houcine; Vorobiev, Eugène

    2015-05-01

    Phenolic content is a primary parameter for vegetables oil quality evaluation, and directly involved in the prevention of oxidation and oil preservation. Several methods have been reported in the literature for polyphenols extraction from seed oil but the approaches commonly used remain manually handled. In this work, we propose a rapid and sensitive method for seed oil polyphenols extraction and identification. For this purpose, polyphenols were extracted from Opuntia stricta Haw seed oil, using high frequency agitation, separated, and then identified using a liquid chromatography-high resolution mass spectrometry method. Our results showed good sensitivity and reproducibility of the developed methods. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. RAPID AND EFFICIENT METHOD FOR ENVIRONMENTAL DNA EXTRACTION AND PURIFICATION FROM SOIL

    Directory of Open Access Journals (Sweden)

    J. Hamedi

    2016-06-01

    Full Text Available Large proportion of microbial population in the world is unculturable. Extraction of total DNA from soil is usually a crucial step considering to the difficulties of study the uncultivable microorganisms. Humic acid is considered as the main inhibitory agent in the environmental DNA studies. Here, we introduced a rapid and efficient method for DNA extraction and purification from soil. Yield of DNA extraction by the presented method was 130 ng/µl. Three conventional methods of DNA extraction including liquid nitrogen incursion, bead beating and sonication were performed as control methods. Yield of DNA extraction by these methods were 110, 90 and 50 ng/µl, respectively. A rapid and efficient one step DNA purification method was introduced instead of hazardous conventional phenol-chloroform methods. Humic acid removal percentage by the introduced method was 95.8 % that is comparable with 97 % gained by the conventional gel extraction method and yield of DNA after purification was 84 % and 73 %, respectively. This study could be useful in molecular ecology and metagenomics study as a fast and reliable method.

  10. Improvements in fast-neutron spectroscopy methods (1961); Amelioration des methodes de spectrometrie des neutrons rapides (1961)

    Energy Technology Data Exchange (ETDEWEB)

    Cambou, F. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1961-02-15

    This research aimed at improving fast-neutron electronic detectors based on n-p elastic scattering. The first part concerns proportional counters; careful constructional methods have made it possible to plot mono-energetic neutron spectra in the range 700 keV - 3 MeV with a resolution of 7 per cent. The second part concerns scintillation counters: an organic scintillator and an inorganic scintillator covered with a thin layer of a scattering agent. An exact study of the types of scintillation has made it possible to develop efficient discriminator circuits. Different neutron spectra plotted in the presence of a strong gamma background are presented. The last part deals with the development of form discrimination methods for the study, in the actual beam, of the elastic scattering of 14.58 MeV electrons. With hydrogen, the distribution f ({phi}) of the recoil protons is f({phi}) = 1 + 0.034 cos {phi} + 0.042 cos{sup 2} {phi}. With tritium the scattering is strongly anisotropic; the curve representing the variation of the differential cross-section for the elastic scattering in the centre of mass system is obtained with a target containing 1 cm{sup 3} of tritium. (author) [French] Le travail a porte sur l'amelioration des detecteurs electroniques de neutrons rapides bases sur la diffusion elastique n-p. La premiere partie est relative aux compteurs proportionnels; des methodes soignees de fabrication ont permis des traces de spectres de neutrons monoenergetiques dans le domaine 700 keV - 3 MeV avec une resolution de 7 pour cent. La deuxieme partie est relative au compteur a scintillations; scintillateur organique et scintillateur mineral recouvert d'un diffuseur mince. Une etude precise des formes de scintillations a permis la mise au point de circuits discriminateurs efficaces. Differents spectres de neutrons traces en presence d'un fond gamma intense sont presentes. La derniere partie est relative a la mise en oeuvre des methodes de discrimination de

  11. A Novel Path Planning for Robots Based on Rapidly-Exploring Random Tree and Particle Swarm Optimizer Algorithm

    Directory of Open Access Journals (Sweden)

    Zhou Feng

    2013-09-01

    Full Text Available A based on Rapidly-exploring Random Tree(RRT and Particle Swarm Optimizer (PSO for path planning of the robot is proposed.First the grid method is built to describe the working space of the mobile robot,then the Rapidly-exploring Random Tree algorithm is used to obtain the global navigation path,and the Particle Swarm Optimizer algorithm is adopted to get the better path.Computer experiment results demonstrate that this novel algorithm can plan an optimal path rapidly in a cluttered environment.The successful obstacle avoidance is achieved,and the model is robust and performs reliably.

  12. Rapid determination method for 2-DCB in irradiated pork by ASE-Al2O3-GC-MS

    Science.gov (United States)

    Li, An; Pan, Li-Gang; Zhang, Xiu-Tong; Jin, Xin-Xin; Ma, Hong-Zao

    2017-01-01

    2-Dodecylcyclobutanone (2-DCB) is validated as a marker for irradiated foodstuffs. However, the preparation methods for the marker compound involve time-consuming and tedious procedures prior to analysis. This paper describes a rapid method for the extraction and cleanup of 2-DCB in irradiated pork. The highly automated extraction procedure is based on accelerated solvent extraction combined with a purification step by Al2O3, which is added to the extraction cell. The overall extraction time is less than 20 min, and the volume of the solvent is 1.5 times that of the extraction cell (34 mL). The recovery of 2-DCB from pork samples for this method is higher than 75%. The method allows detecting pork irradiated at low doses (0.5 kGy). The proposed method is considered an alternative to the Soxhlet extraction and Florisil chromatography method currently in use.

  13. [Development of a rapid test kit for antibody to HIV by nano immunomagnetic lateral flow method].

    Science.gov (United States)

    Yang, Fa-qing; Lee, Tony; Wang, Chao-nan; Sun, Shu-ye; Li, Shan-shan; Tian, Hui

    2010-06-01

    To develop a rapid test kit for antibody to HIV by nano immunomagnetic lateral flow method. A rapid test kit was developed by conjugation of the HIV antigen gp41 and gp36 to 200nm super paramagnetic particles by carbodiimide (EDC) and coating of the HIV antigen gp41 and gp36 to nitrocellulose membrane. Then the kit was evaluated with serials of experiments. The kit was qualified with examination of national reference panel of anti-HIV antibody for colloidal gold diagnostic kit. The sensitivity was 100% by tested with 20 HIV antibody positive sera, the specificity was 98.5% by tested with 600 HIV antibody negative sera, respectively. The stability of the kit was over 12 month by storage at room temperature. A diagnostic kit for antibody to HIV was developed with the advantages of convenience, rapid test, good stability and point of care.

  14. A Boussinesq-type method for fully nonlinear waves interacting with a rapidly varying bathymetry

    DEFF Research Database (Denmark)

    Madsen, Per A.; Fuhrman, David R.; Wang, Benlong

    2006-01-01

    New equations are derived for fully nonlinear and highly dispersive water waves interacting with a rapidly varying bathymetry. The derivation is an extension of a recent high order Boussinesq type formulation valid on a mildly sloping bottom. It is based on a series expansion from a rapidly...... locally deteriorate, and we provide a guideline for using this technique within acceptable accuracy bounds. Numerical results are given for the linear reflection from a plane shelf, a Gaussian shaped trench, and a symmetric trench with sloped transitions. Furthermore, we simulate the linear class I...

  15. A Simple and Rapid Method for Preparing a Cell-Free Bacterial Lysate for Protein Synthesis.

    Directory of Open Access Journals (Sweden)

    Nitzan Krinsky

    Full Text Available Cell-free protein synthesis (CFPS systems are important laboratory tools that are used for various synthetic biology applications. Here, we present a simple and inexpensive laboratory-scale method for preparing a CFPS system from E. coli. The procedure uses basic lab equipment, a minimal set of reagents, and requires less than one hour to process the bacterial cell mass into a functional S30-T7 extract. BL21(DE3 and MRE600 E. coli strains were used to prepare the S30-T7 extract. The CFPS system was used to produce a set of fluorescent and therapeutic proteins of different molecular weights (up to 66 kDa. This system was able to produce 40-150 μg-protein/ml, with variations depending on the plasmid type, expressed protein and E. coli strain. Interestingly, the BL21-based CFPS exhibited stability and increased activity at 40 and 45°C. To the best of our knowledge, this is the most rapid and affordable lab-scale protocol for preparing a cell-free protein synthesis system, with high thermal stability and efficacy in producing therapeutic proteins.

  16. A method for the rapid detection and identification of halo blight pathogen on common bean

    Directory of Open Access Journals (Sweden)

    Popović Tatjana

    2014-01-01

    Full Text Available A diagnostic method based on nested-PCR, followed by ELISA and conventional bacteriology tests, for the rapid and reliable detection of halo blight pathogen Pseudomonas savastanoi pv. phaseolicola (Psp collected from infected bean leaves and seeds is described. Psp formed white, small and flat colonies on nutrient agar medium, creamy white, flat and circular on Milk-Tween agar medium and light yellow, convex and shiny on modified sucrose peptone agar medium. Eighteen Gram-negative, catalase-positive and oxidase-negative strains were subjected to nested PCR with primers P 5.1/P 3.1 and P 5.2/P 3.2, which directed the amplification of the 450 bp target DNA fragment in all tested strains. According to the results of DAS- and PTA-ELISA with respect to reactivity to specific antibodies, all analyzed strains belonged to Psp bacterium. Pathogenicity was tested on bean pods and cotyledon leaves, on which greasy spots were formed. Psp did not cause hypersensitive reaction on the leaves of tobacco and geranium. Strains produced levan, fluorescent pigment, oxidative metabolism of glucose, did not reduce nitrate, did not produce indole and H2S, did not hydrolyze starch, gelatin and esculin; they produced acid from glucose, mannose, sucrose and glycerol, and did not produce acid from maltose, starch, esculin, dulcite, sorbitol, inositol and erythritol.

  17. Determination of rapid chlorination rate constants by a stopped-flow spectrophotometric competition kinetics method.

    Science.gov (United States)

    Song, Dean; Liu, Huijuan; Qiang, Zhimin; Qu, Jiuhui

    2014-05-15

    Free chlorine is extensively used for water and wastewater disinfection nowadays. However, it still remains a big challenge to determine the rate constants of rapid chlorination reactions although competition kinetics and stopped-flow spectrophotometric (SFS) methods have been employed individually to investigate fast reaction kinetics. In this work, we proposed an SFS competition kinetics method to determine the rapid chlorination rate constants by using a common colorimetric reagent, N,N-diethyl-p-phenylenediamine (DPD), as a reference probe. A kinetic equation was first derived to estimate the reaction rate constant of DPD towards chlorine under a given pH and temperature condition. Then, on that basis, an SFS competition kinetics method was proposed to determine directly the chlorination rate constants of several representative compounds including tetracycline, ammonia, and four α-amino acids. Although Cl2O is more reactive than HOCl, its contribution to the overall chlorination kinetics of the test compounds could be neglected in this study. Finally, the developed method was validated through comparing the experimentally measured chlorination rate constants of the selected compounds with those obtained or calculated from literature and analyzing with Taft's correlation as well. This study demonstrates that the SFS competition kinetics method can measure the chlorination rate constants of a test compound rapidly and accurately. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. Rapid Column Extraction Method for Actinides and Sr-89/90 in Water Samples

    Energy Technology Data Exchange (ETDEWEB)

    MAXWELL III, SHERROD L.

    2005-06-15

    The SRS Environmental Laboratory analyzes water samples for environmental monitoring, including river water and ground water samples. A new, faster actinide and strontium 89/90 separation method has been developed and implemented to improve productivity, reduce labor costs and add capacity to this laboratory. This method uses stacked TEVA Resin{reg_sign}, TRU Resin{reg_sign} and Sr-Resin{reg_sign} cartridges from Eichrom Technologies (Darien, IL, USA) that allows the rapid separation of plutonium (Pu), neptunium (Np), uranium (U), americium (Am), curium (Cm) and thorium (Th) using a single multi-stage column combined with alpha spectrometry. By using vacuum box cartridge technology with rapid flow rates, sample preparation time is minimized. The method can be used for routine analysis or as a rapid method for emergency preparedness. Thorium and curium are often analyzed separately due to the interference of the daughter of Th-229 tracer, actinium (Ac)-225, on curium isotopes when measured by alpha spectrometry. This new method also adds a separation step using DGA Resin{reg_sign}, (Diglycolamide Resin, Eichrom Technologies) to remove Ac-225 and allow the separation and analysis of thorium isotopes and curium isotopes at the same time.

  19. Adapting and Evaluating a Rapid, Low-Cost Method to Enumerate Flies in the Household Setting.

    Science.gov (United States)

    Wolfe, Marlene K; Dentz, Holly N; Achando, Beryl; Mureithi, MaryAnne; Wolfe, Tim; Null, Clair; Pickering, Amy J

    2017-02-08

    Diarrhea is a leading cause of death among children under 5 years of age worldwide. Flies are important vectors of diarrheal pathogens in settings lacking networked sanitation services. There is no standardized method for measuring fly density in households; many methods are cumbersome and unvalidated. We adapted a rapid, low-cost fly enumeration technique previously developed for industrial settings, the Scudder fly grill, for field use in household settings. We evaluated its performance in comparison to a sticky tape fly trapping method at latrine and food preparation areas among households in rural Kenya. The grill method was more sensitive; it detected the presence of any flies at 80% (433/543) of sampling locations versus 64% (348/543) of locations by the sticky tape. We found poor concordance between the two methods, suggesting that standardizing protocols is important for comparison of fly densities between studies. Fly species identification was feasible with both methods; however, the sticky tape trap allowed for more nuanced identification. Both methods detected a greater presence of bottle flies near latrines compared with food preparation areas (P < 0.01). The grill method detected more flies at the food preparation area compared with near the latrine (P = 0.014) while the sticky tape method detected no difference. We recommend the Scudder grill as a sensitive fly enumeration tool that is rapid and low cost to implement. © The American Society of Tropical Medicine and Hygiene.

  20. Rapid and effective DNA extraction method with bead grinding for a large amount of fungal DNA.

    Science.gov (United States)

    Watanabe, M; Lee, K; Goto, K; Kumagai, S; Sugita-Konishi, Y; Hara-Kudo, Y

    2010-06-01

    To identify a rapid method for extracting a large amount of DNA from fungi associated with food hygiene, extraction methods were compared using fungal pellets formed rapidly in liquid media. Combinations of physical and chemical methods or commercial kits were evaluated with 3 species of yeast, 10 species of ascomycetous molds, and 4 species of zygomycetous molds. Bead grinding was the physical method, followed by chemical methods involving sodium dodecyl sulfate (SDS), cetyl trimethyl ammonium bromide (CTAB), and benzyl chloride and two commercial kits. Quantity was calculated by UV absorbance at 260 nm, quality was determined by the ratio of UV absorbance at 260 and 280 nm, and gene amplifications and electrophoresis profiles of whole genomes were analyzed. Bead grinding with the SDS method was the most effective for DNA extraction for yeasts and ascomycetous molds, and bead grinding with the CTAB method was most effective with zygomycetous molds. For both groups of molds, bead grinding with the CTAB method was the best approach for DNA extraction. Because this combination also is relatively effective for yeasts, it can be used to extract a large amount of DNA from a wide range of fungi. The DNA extraction methods are useful for developing gene indexes to identify fungi with molecular techniques, such as DNA fingerprinting.

  1. A rapid chromatographic method for quality control of technetium-99m-bicisate.

    Science.gov (United States)

    Amin, K C; Saha, G B; Go, R T

    1997-03-01

    The purpose of this work was to develop a simple and rapid method to determine the radiochemical purity of 99mTc-bicisate. A rapid paper chromatographic (PC) method was developed to determine the radiochemical purity of 99mTc-bicisate and compare the results with those of the manufacturer's recommended method. The present PC method included Whatman 3MM paper as the solid phase and ethyl acetate as the solvent. The time for chromatography by this technique was 4-5 min compared to about 23 min by the manufacturer's method. The Rf value of 99mTc-bicisate (Rf = 0.9-1.0) was widely different from those of 99mTcO4- and reduced 99mTc (Rf = 0.0 for both) so the chromatographic strip after development could be readily cut into two segments, in order to determine the labeling yield. No significant difference in labeling yields was found between the present method and the manufacturer's method. The PC method using Whatman 3MM paper and ethyl acetate is a simple and fast technique to determine the radiochemical purity of 99mTc-bicisate and may be substituted for the manufacturer's recommended method to save time.

  2. ADVANTAGES OF RAPID METHOD FOR DETERMINING SCALE MASS AND DECARBURIZED LAYER OF ROLLED COIL STEEL

    Directory of Open Access Journals (Sweden)

    E. V. Parusov

    2016-08-01

    Full Text Available Purpose. To determine the universal empirical relationships that allow for operational calculation of scale mass and decarbonized layer depth based on the parameters of the technological process for rolled coil steel production. Methodology. The research is carried out on the industrial batches of the rolled steel of SAE 1006 and SAE 1065 grades. Scale removability was determined in accordance with the procedure of «Bekaert» company by the specifi-cations: GA-03-16, GA-03-18, GS-03-02, GS-06-01. The depth of decarbonized layer was identified in accordance with GOST 1763-68 (M method. Findings. Analysis of experimental data allowed us to determine the rational temperature of coil formation of the investigated steel grades, which provide the best possible removal of scale from the metal surface, a minimal amount of scale, as well as compliance of the metal surface color with the require-ments of European consumers. Originality. The work allowed establishing correlation of the basic quality indicators of the rolled coil high carbon steel (scale mass, depth of decarbonized layer and inter-laminar distance in pearlite with one of the main parameters (coil formation temperature of the deformation and heat treatment mode. The re-sulting regression equations, without metallographic analysis, can be used to determine, with a minimum error, the quantitative values of the total scale mass, depth of decarbonized layer and the average inter-lamellar distance in pearlite of the rolled coil high carbon steel. Practical value. Based on the specifications of «Bekaert» company (GA-03-16, GA-03-18, GS-03-02 and GS-06-01 the method of testing descaling by mechanical means from the surface of the rolled coil steel of low- and high-carbon steel grades was developed and approved in the environment of PJSC «ArcelorMittal Kryvyi Rih». The work resulted in development of the rapid method for determination of total and remaining scale mass on the rolled coil steel

  3. A nationwide web-based automated system for early outbreak detection and rapid response in China

    Directory of Open Access Journals (Sweden)

    Yilan Liao

    2011-03-01

    Full Text Available Timely reporting, effective analyses and rapid distribution of surveillance data can assist in detecting the aberration of disease occurrence and further facilitate a timely response. In China, a new nationwide web-based automated system for outbreak detection and rapid response was developed in 2008. The China Infectious Disease Automated-alert and Response System (CIDARS was developed by the Chinese Center for Disease Control and Prevention based on the surveillance data from the existing electronic National Notifiable Infectious Diseases Reporting Information System (NIDRIS started in 2004. NIDRIS greatly improved the timeliness and completeness of data reporting with real time reporting information via the Internet. CIDARS further facilitates the data analysis, aberration detection, signal dissemination, signal response and information communication needed by public health departments across the country. In CIDARS, three aberration detection methods are used to detect the unusual occurrence of 28 notifiable infectious diseases at the county level and to transmit that information either in real-time or on a daily basis. The Internet, computers and mobile phones are used to accomplish rapid signal generation and dissemination, timely reporting and reviewing of the signal response results. CIDARS has been used nationwide since 2008; all Centers for Disease Control and Prevention (CDC in China at the county, prefecture, provincial and national levels are involved in the system. It assists with early outbreak detection at the local level and prompts reporting of unusual disease occurrences or potential outbreaks to CDCs throughout the country.

  4. A rapid PCR based method to distinguish between Enterococcus ...

    African Journals Online (AJOL)

    ... by using Efm1/Efm2, Efs1/Efs2 and Eh1/Eh2 primers, ten different genotypes were recognised. Enterococcus faecium was the dominant biotype followed by E. faecalis. The results suggest that wild bacterial populations should be preserved in order to protect the traditional lactic fermentation and for product innovation.

  5. Rapid Analytical Methods for On-Site Triage for Traumatic Brain Injury

    Science.gov (United States)

    North, Stella H.; Shriver-Lake, Lisa C.; Taitt, Chris R.; Ligler, Frances S.

    2012-07-01

    Traumatic brain injury (TBI) results from an event that causes rapid acceleration and deceleration of the brain or penetration of the skull with an object. Responses to stimuli and questions, loss of consciousness, and altered behavior are symptoms currently used to justify brain imaging for diagnosis and therapeutic guidance. Tests based on such symptoms are susceptible to false-positive and false-negative results due to stress, fatigue, and medications. Biochemical markers of neuronal damage and the physiological response to that damage are being identified. Biosensors capable of rapid measurement of such markers in the circulation offer a solution for on-site triage, as long as three criteria are met: (a) Recognition reagents can be identified that are sufficiently sensitive and specific, (b) the biosensor can provide quantitative assessment of multiple markers rapidly and simultaneously, and (c) both the sensor and reagents are designed for use outside the laboratory.

  6. A simple and rapid spectrophotometric method for determination of thiophanate-methyl in commercial formulations and its residues in foodstuffs.

    Science.gov (United States)

    Verma, Balbir C; Sood, Sumita; Chauhan, Chetan; Sharma, Devender K

    2004-01-01

    A new, simple, rapid, and sensitive spectrophotometric method for the determination of thiophanate-methyl, based on its reaction with cobalt(II) in the presence of triethylamine, has been developed. The yellowish green color that develops instantaneously on mixing the fungicide with the reagents in dimethylformamide is stable for at least 2 h and has maximum absorbance at 360 nm. The method has been successfully applied to the determination of thiophanate-methyl in its commercial formulations and residues on grains and apples. A photometric titration procedure for formulation analysis of the fungicide has also been developed.

  7. Cochrane Rapid Reviews Methods Group to play a leading role in guiding the production of informed high-quality, timely research evidence syntheses

    Directory of Open Access Journals (Sweden)

    Chantelle Garritty

    2016-10-01

    Full Text Available Abstract Background Policymakers and healthcare stakeholders are increasingly seeking evidence to inform the policymaking process, and often use existing or commissioned systematic reviews to inform decisions. However, the methodologies that make systematic reviews authoritative take time, typically 1 to 2 years to complete. Outside the traditional SR timeline, “rapid reviews” have emerged as an efficient tool to get evidence to decision-makers more quickly. However, the use of rapid reviews does present challenges. To date, there has been limited published empirical information about this approach to compiling evidence. Thus, it remains a poorly understood and ill-defined set of diverse methodologies with various labels. In recent years, the need to further explore rapid review methods, characteristics, and their use has been recognized by a growing network of healthcare researchers, policymakers, and organizations, several with ties to Cochrane, which is recognized as representing an international gold standard for high-quality, systematic reviews. Purpose In this commentary, we introduce the newly established Cochrane Rapid Reviews Methods Group developed to play a leading role in guiding the production of rapid reviews given they are increasingly employed as a research synthesis tool to support timely evidence-informed decision-making. We discuss how the group was formed and outline the group’s structure and remit. We also discuss the need to establish a more robust evidence base for rapid reviews in the published literature, and the importance of promoting registration of rapid review protocols in an effort to promote efficiency and transparency in research. Conclusion As with standard systematic reviews, the core principles of evidence-based synthesis should apply to rapid reviews in order to minimize bias to the extent possible. The Cochrane Rapid Reviews Methods Group will serve to establish a network of rapid review stakeholders

  8. Activity – based costing method

    Directory of Open Access Journals (Sweden)

    Èuchranová Katarína

    2001-06-01

    Full Text Available Activity based costing is a method of identifying and tracking the operating costs directly associated with processing items. It is the practice of focusing on some unit of output, such as a purchase order or an assembled automobile and attempting to determine its total as precisely as poccible based on the fixed and variable costs of the inputs.You use ABC to identify, quantify and analyze the various cost drivers (such as labor, materials, administrative overhead, rework. and to determine which ones are candidates for reduction.A processes any activity that accepts inputs, adds value to these inputs for customers and produces outputs for these customers. The customer may be either internal or external to the organization. Every activity within an organization comprimes one or more processes. Inputs, controls and resources are all supplied to the process.A process owner is the person responsible for performing and or controlling the activity.The direction of cost through their contact to partial activity and processes is a new modern theme today. Beginning of this method is connected with very important changes in the firm processes.ABC method is a instrument , that bring a competitive advantages for the firm.

  9. High-throughput rapid-prototyping of low-cost paper-based microfluidics.

    Science.gov (United States)

    Ghaderinezhad, Fariba; Amin, Reza; Temirel, Mikail; Yenilmez, Bekir; Wentworth, Adam; Tasoglu, Savas

    2017-06-15

    Paper-based micro analytical devices offer significant advantages compared to the conventional microfluidic chips including cost-effectiveness, ease of fabrication, and ease of use while preserving critical features including strong capillary action and biological compatibility. In this work, we demonstrate an inexpensive, rapid method for high-throughput fabrication of paper-based microfluidics by patterning hydrophobic barriers using a desktop pen plotter integrated with a custom-made, low-cost paper feeder. We tested various types of commercial permanent markers and compared their water-resistant capabilities for creating hydrophobic barriers. Additionally, we studied the performance of markers with different types of paper, plotting speeds, and pattern dimensions. To verify the effectiveness of the presented fabrication method, colorimetric analysis was performed on the results of a glucose assay.

  10. Development of a rapid method for the quantitative determination of deoxynivalenol using Quenchbody

    Energy Technology Data Exchange (ETDEWEB)

    Yoshinari, Tomoya [Division of Microbiology, National Institute of Health Sciences, 1-18-1, Kamiyoga, Setagaya-ku, Tokyo 158-8501 (Japan); Ohashi, Hiroyuki; Abe, Ryoji; Kaigome, Rena [Biomedical Division, Ushio Inc., 1-12 Minamiwatarida-cho, Kawasaki-ku, Kawasaki 210-0855 (Japan); Ohkawa, Hideo [Research Center for Environmental Genomics, Kobe University, 1-1 Rokkodai, Nada, Kobe 657-8501 (Japan); Sugita-Konishi, Yoshiko, E-mail: y-konishi@azabu-u.ac.jp [Department of Food and Life Science, Azabu University, 1-17-71 Fuchinobe, Chuo-ku, Sagamihara, Kanagawa 252-5201 (Japan)

    2015-08-12

    Quenchbody (Q-body) is a novel fluorescent biosensor based on the antigen-dependent removal of a quenching effect on a fluorophore attached to antibody domains. In order to develop a method using Q-body for the quantitative determination of deoxynivalenol (DON), a trichothecene mycotoxin produced by some Fusarium species, anti-DON Q-body was synthesized from the sequence information of a monoclonal antibody specific to DON. When the purified anti-DON Q-body was mixed with DON, a dose-dependent increase in the fluorescence intensity was observed and the detection range was between 0.0003 and 3 mg L{sup −1}. The coefficients of variation were 7.9% at 0.003 mg L{sup −1}, 5.0% at 0.03 mg L{sup −1} and 13.7% at 0.3 mg L{sup −1}, respectively. The limit of detection was 0.006 mg L{sup −1} for DON in wheat. The Q-body showed an antigen-dependent fluorescence enhancement even in the presence of wheat extracts. To validate the analytical method using Q-body, a spike-and-recovery experiment was performed using four spiked wheat samples. The recoveries were in the range of 94.9–100.2%. The concentrations of DON in twenty-one naturally contaminated wheat samples were quantitated by the Q-body method, LC-MS/MS and an immunochromatographic assay kit. The LC-MS/MS analysis showed that the levels of DON contamination in the samples were between 0.001 and 2.68 mg kg{sup −1}. The concentrations of DON quantitated by LC-MS/MS were more strongly correlated with those using the Q-body method (R{sup 2} = 0.9760) than the immunochromatographic assay kit (R{sup 2} = 0.8824). These data indicate that the Q-body system for the determination of DON in wheat samples was successfully developed and Q-body is expected to have a range of applications in the field of food safety. - Highlights: • A rapid method for quantitation of DON using Q-body has been developed. • A recovery test using the anti-DON Q-body was performed. • The concentrations of DON in wheat

  11. New method for vitrifying water and other liquids by rapid cooling of their aerosols

    Science.gov (United States)

    Mayer, Erwin

    1985-07-01

    A method for the vitrification of pure liquid water and dilute aqueous solutions is described which is the only one without a liquid cryomedium for heat transfer: rapid cooling of aqueous aerosol droplets on a solid cryoplate. This method is not limited to water and aqueous solutions, but can be used for the vitrification of any liquid aerosol, the only impurity being some codeposited vapor. The method can be applied in diverse fields such as cryobiology, cryomicroscopy, and low-temperature spectroscopy of water and dilute aqueous solutions to avoid the formation of crystalline ice.

  12. RAPID METHOD FOR PLUTONIUM, AMERICIUM AND CURIUM IN VERY LARGE SOIL SAMPLES

    Energy Technology Data Exchange (ETDEWEB)

    Maxwell, S

    2007-01-08

    The analysis of actinides in environmental soil and sediment samples is very important for environmental monitoring. There is a need to measure actinide isotopes with very low detection limits. A new, rapid actinide separation method has been developed and implemented that allows the measurement of plutonium, americium and curium isotopes in very large soil samples (100-200 g) with high chemical recoveries and effective removal of matrix interferences. This method uses stacked TEVA Resin{reg_sign}, TRU Resin{reg_sign} and DGA-Resin{reg_sign} cartridges from Eichrom Technologies (Darien, IL, USA) that allows the rapid separation of plutonium (Pu), americium (Am), and curium (Cm) using a single multistage column combined with alpha spectrometry. The method combines an acid leach step and innovative matrix removal using cerium fluoride precipitation to remove the difficult soil matrix. This method is unique in that it provides high tracer recoveries and effective removal of interferences with small extraction chromatography columns instead of large ion exchange resin columns that generate large amounts of acid waste. By using vacuum box cartridge technology with rapid flow rates, sample preparation time is minimized.

  13. A rapid method for assessing the environmental performance of commercial farms in the Pampas of Argentina.

    Science.gov (United States)

    Viglizzo, E F; Frank, F; Bernardos, J; Buschiazzo, D E; Cabo, S

    2006-06-01

    The generation of reliable updated information is critical to support the harmonization of socio-economic and environmental issues in a context of sustainable development. The agro-environmental assessment and management of agricultural systems often relies on indicators that are necessary to make sound decisions. This work aims to provide an approach to (a) assess the environmental performance of commercial farms in the Pampas of Argentina, and (b) propose a methodological framework to calculate environmental indicators that can rapidly be applied to practical farming. 120 commercial farms scattered across the Pampas were analyzed in this study during 2002 and 2003. Eleven basic indicators were identified and calculation methods described. Such indicators were fossil energy (FE) use, FE use efficiency, nitrogen (N) balance, phosphorus (P) balance, N contamination risk, P contamination risk, pesticide contamination risk, soil erosion risk, habitat intervention, changes in soil carbon stock, and balance of greenhouse gases. A model named Agro-Eco-Index was developed on a Microsoft-Excel support to incorporate on-farm collected data and facilitate the calculation of indicators by users. Different procedures were applied to validate the model and present the results to the users. Regression models (based on linear and non-linear models) were used to validate the comparative performance of the study farms across the Pampas. An environmental dashboard was provided to represent in a graphical way the behavior of farms. The method provides a tool to discriminate environmentally friendly farms from those that do not pay enough attention to environmental issues. Our procedure might be useful for implementing an ecological certification system to reward a good environmental behavior in society (e.g., through tax benefits) and generate a commercial advantage (e.g., through the allocation of green labels) for committed farmers.

  14. Rapid diagnosis of sepsis with TaqMan-Based multiplex real-time PCR.

    Science.gov (United States)

    Liu, Chang-Feng; Shi, Xin-Ping; Chen, Yun; Jin, Ye; Zhang, Bing

    2018-02-01

    The survival rate of septic patients mainly depends on a rapid and reliable diagnosis. A rapid, broad range, specific and sensitive quantitative diagnostic test is the urgent need. Thus, we developed a TaqMan-Based Multiplex real-time PCR assays to identify bloodstream pathogens within a few hours. Primers and TaqMan probes were designed to be complementary to conserved regions in the 16S rDNA gene of different kinds of bacteria. To evaluate accurately, sensitively, and specifically, the known bacteria samples (Standard strains, whole blood samples) are determined by TaqMan-Based Multiplex real-time PCR. In addition, 30 blood samples taken from patients with clinical symptoms of sepsis were tested by TaqMan-Based Multiplex real-time PCR and blood culture. The mean frequency of positive for Multiplex real-time PCR was 96% at a concentration of 100 CFU/mL, and it was 100% at a concentration greater than 1000 CFU/mL. All the known blood samples and Standard strains were detected positively by TaqMan-Based Multiplex PCR, no PCR products were detected when DNAs from other bacterium were used in the multiplex assay. Among the 30 patients with clinical symptoms of sepsis, 18 patients were confirmed positive by Multiplex real-time PCR and seven patients were confirmed positive by blood culture. TaqMan-Based Multiplex real-time PCR assay with highly sensitivity, specificity and broad detection range, is a rapid and accurate method in the detection of bacterial pathogens of sepsis and should have a promising usage in the diagnosis of sepsis. © 2017 Wiley Periodicals, Inc.

  15. A novel sample preparation method using rapid nonheated saponification method for the determination of cholesterol in emulsified foods.

    Science.gov (United States)

    Jeong, In-Seek; Kwak, Byung-Man; Ahn, Jang-Hyuk; Leem, Donggil; Yoon, Taehyung; Yoon, Changyong; Jeong, Jayoung; Park, Jung-Min; Kim, Jin-Man

    2012-10-01

    In this study, nonheated saponification was employed as a novel, rapid, and easy sample preparation method for the determination of cholesterol in emulsified foods. Cholesterol content was analyzed using gas chromatography with a flame ionization detector (GC-FID). The cholesterol extraction method was optimized for maximum recovery from baby food and infant formula. Under these conditions, the optimum extraction solvent was 10 mL ethyl ether per 1 to 2 g sample, and the saponification solution was 0.2 mL KOH in methanol. The cholesterol content in the products was determined to be within the certified range of certified reference materials (CRMs), NIST SRM 1544 and SRM 1849. The results of the recovery test performed using spiked materials were in the range of 98.24% to 99.45% with an relative standard devitation (RSD) between 0.83% and 1.61%. This method could be used to reduce sample pretreatment time and is expected to provide an accurate determination of cholesterol in emulsified food matrices such as infant formula and baby food. A novel, rapid, and easy sample preparation method using nonheated saponification was developed for cholesterol detection in emulsified foods. Recovery tests of CRMs were satisfactory, and the recoveries of spiked materials were accurate and precise. This method was effective and decreased the time required for analysis by 5-fold compared to the official method. © 2012 Institute of Food Technologists®

  16. Simple and rapid method for the isolation of forskolin from Coleus forskohlii by charcoal column chromatography.

    Science.gov (United States)

    Saleem, A M; Dhasan, P B; Rafiullah, M R M

    2006-01-06

    A simple, safe, rapid and economical method was developed for the isolation of high-purity forskolin from Coleus forskohlii roots using activated charcoal as an adsorbent in a column. The elution was carried out under reduced pressure to make the process rapid. Activated charcoal acted as a reversed phase adsorbent and allowed elution of forskolin without much impurities. The residue, obtained from the eluate was purified and crystallized using different solvent mixtures to obtain pure forskolin. The forskolin isolated was analyzed and characterized by UV, IR, RP-HPLC, electrospray ionization MS, 1H NMR and 13C NMR. The yield was 0.097% w/w (RSD 5.6%). The purity was 96.9% w/w (RSD 0.3%) as determined by RP-HPLC. The present method enables researchers to produce high-purity forskolin in their labs by using common chemicals.

  17. Evaluation of methods for rapid determination of freezing point of aviation fuels

    Science.gov (United States)

    Mathiprakasam, B.

    1982-01-01

    Methods for identification of the more promising concepts for the development of a portable instrument to rapidly determine the freezing point of aviation fuels are described. The evaluation process consisted of: (1) collection of information on techniques previously used for the determination of the freezing point, (2) screening and selection of these techniques for further evaluation of their suitability in a portable unit for rapid measurement, and (3) an extensive experimental evaluation of the selected techniques and a final selection of the most promising technique. Test apparatuses employing differential thermal analysis and the change in optical transparency during phase change were evaluated and tested. A technique similar to differential thermal analysis using no reference fuel was investigated. In this method, the freezing point was obtained by digitizing the data and locating the point of inflection. Results obtained using this technique compare well with those obtained elsewhere using different techniques. A conceptual design of a portable instrument incorporating this technique is presented.

  18. Rapid and Sensitive Determination of Lipid Oxidation Using the Reagent Kit Based on Spectrophotometry (FOODLABfat System

    Directory of Open Access Journals (Sweden)

    Chang Woo Kwon

    2016-01-01

    Full Text Available The reliability and availability of FOODLABfat system for determining acid value (AV and peroxide value (POV were assessed during the hydrolytic rancidification and lipid oxidation of edible oils. This reagent kit based on spectrophotometry was compared to the official methods (ISO 660 and 3960 protocols based on manual titration employing the standard mixture for the simulated oxidation models and edible oils during the thermally induced oxidation at 180°C. The linear regression line of standard mixture and the significant difference of thermally oxidized time course study determined between them showed high correlations (R2=0.998 and p<0.05 in both AVs and POVs. Considering ISO protocols with a probability of human error in manual titration, the rapidness and simplicity of the reagent kit based on spectrophotometry make it a promising alternative to monitor the lipid oxidation of edible oils and lipid-containing foods.

  19. Flow-Based Systems for Rapid and High-Precision Enzyme Kinetics Studies

    Directory of Open Access Journals (Sweden)

    Supaporn Kradtap Hartwell

    2012-01-01

    Full Text Available Enzyme kinetics studies normally focus on the initial rate of enzymatic reaction. However, the manual operation of steps of the conventional enzyme kinetics method has some drawbacks. Errors can result from the imprecise time control and time necessary for manual changing the reaction cuvettes into and out of the detector. By using the automatic flow-based analytical systems, enzyme kinetics studies can be carried out at real-time initial rate avoiding the potential errors inherent in manual operation. Flow-based systems have been developed to provide rapid, low-volume, and high-precision analyses that effectively replace the many tedious and high volume requirements of conventional wet chemistry analyses. This article presents various arrangements of flow-based techniques and their potential use in future enzyme kinetics applications.

  20. Rapid direct methods for enumeration of specific, active bacteria in water and biofilms

    Science.gov (United States)

    McFeters, G. A.; Pyle, B. H.; Lisle, J. T.; Broadaway, S. C.

    1999-01-01

    Conventional methods for detecting indicator and pathogenic bacteria in water may underestimate the actual population due to sublethal environmental injury, inability of the target bacteria to take up nutrients and other physiological factors which reduce bacterial culturability. Rapid and direct methods are needed to more accurately detect and enumerate active bacteria. Such a methodological advance would provide greater sensitivity in assessing the microbiological safety of water and food. The principle goal of this presentation is to describe novel approaches we have formulated for the rapid and simultaneous detection of bacteria plus the determination of their physiological activity in water and other environmental samples. The present version of our method involves the concentration of organisms by membrane filtration or immunomagnetic separation and combines an intracellular fluorochrome (CTC) for assessment of respiratory activity plus fluorescent-labelled antibody detection of specific bacteria. This approach has also been successfully used to demonstrate spatial and temporal heterogeneities of physiological activities in biofilms when coupled with cryosectioning. Candidate physiological stains include those capable of determining respiratory activity, membrane potential, membrane integrity, growth rate and cellular enzymatic activities. Results obtained thus far indicate that immunomagnetic separation can provide a high degree of sensitivity in the recovery of seeded target bacteria (Escherichia coli O157:H7) in water and hamburger. The captured and stained target bacteria are then enumerated by either conventional fluorescence microscopy or ChemScan(R), a new instrument that is very sensitive and rapid. The ChemScan(R) laser scanning instrument (Chemunex, Paris, France) provides the detection of individual fluorescently labelled bacterial cells using three emission channels in less than 5 min. A high degree of correlation has been demonstrated between

  1. New multiplex PCR methods for rapid screening of genetically modified organisms in foods

    OpenAIRE

    Nelly eDatukishvili; Tamara eKutateladze; Inga eGabriadze; Kakha eBitskinashvili; Boris eVishnepolsky

    2015-01-01

    We present novel multiplex PCR methods for rapid and reliable screening of genetically modified organisms (GMOs). New designed PCR primers targeting four frequently used GMO specific sequences permitted identification of new DNA markers, in particular 141 bp fragment of cauliflower mosaic virus (CaMV) 35S promoter, 224 bp fragment of Agrobacterium tumefaciens nopaline synthase (NOS) terminator, 256 bp fragment of 5-enolppyruvylshikimate-phosphate synthase (epsps) gene and 258 bp fragment of C...

  2. A rapid and low-cost DNA extraction method for isolating ...

    African Journals Online (AJOL)

    The price of commercial DNA extraction methods makes the routine use of polymerase chain reaction amplification (PCR) based methods rather costly for scientists in developing countries. A guanidium thiocayante-based DNA extraction method was investigated in this study for the isolation of Escherichia coli (E. coli) DNA ...

  3. Femur Model Reconstruction Based on Reverse Engineering and Rapid Prototyping

    Science.gov (United States)

    Tang, Tongming; Zhang, Zheng; Ni, Hongjun; Deng, Jiawen; Huang, Mingyu

    Precise reconstruction of 3D models is fundamental and crucial to the researches of human femur. In this paper we present our approach towards tackling this problem. The surface of a human femur was scanned using a hand-held 3D laser scanner. The data obtained, in the form of point cloud, was then processed using the reverse engineering software Geomagic and the CAD/CAM software CimatronE to reconstruct a digital 3D model. The digital model was then used by the rapid prototyping machine to build a physical model of human femur using 3D printing. The geometric characteristics of the obtained physical model matched that of the original femur. The process of "physical object - 3D data - digital 3D model - physical model" presented in this paper provides a foundation of precise modeling for the digital manufacturing, virtual assembly, stress analysis, and simulated surgery of artificial bionic femurs.

  4. Conventional rapid latex agglutination in estimation of von Willebrand factor: method revisited and potential clinical applications.

    Science.gov (United States)

    Mahat, Marianor; Abdullah, Wan Zaidah; Hussin, Che Maraina Che

    2014-01-01

    Measurement of von Willebrand factor antigen (VWF : Ag) levels is usually performed in a specialised laboratory which limits its application in routine clinical practice. So far, no commercial rapid test kit is available for VWF : Ag estimation. This paper discusses the technical aspect of latex agglutination method which was established to suit the purpose of estimating von Willebrand factor (VWF) levels in the plasma sample. The latex agglutination test can be performed qualitatively and semiquantitatively. Reproducibility, stability, linearity, limit of detection, interference, and method comparison studies were conducted to evaluate the performance of this test. Semiquantitative latex agglutination test was strongly correlated with the reference immunoturbidimetric assay (Spearman's rho = 0.946, P agglutination test and the reference assay. Using the scoring system for the rapid latex test, no agglutination is with 0% VWF : Ag (control negative), 1+ reaction is equivalent to 150% VWF : Ag (when comparing with immunoturbidimetric assay). The findings from evaluation studies suggest that latex agglutination method is suitable to be used as a rapid test kit for the estimation of VWF : Ag levels in various clinical conditions associated with high levels and low levels of VWF : Ag.

  5. GSMA: Gene Set Matrix Analysis, An Automated Method for Rapid Hypothesis Testing of Gene Expression Data

    Directory of Open Access Journals (Sweden)

    Chris Cheadle

    2007-01-01

    Full Text Available Background: Microarray technology has become highly valuable for identifying complex global changes in gene expression patterns. The assignment of functional information to these complex patterns remains a challenging task in effectively interpreting data and correlating results from across experiments, projects and laboratories. Methods which allow the rapid and robust evaluation of multiple functional hypotheses increase the power of individual researchers to data mine gene expression data more efficiently.Results: We have developed (gene set matrix analysis GSMA as a useful method for the rapid testing of group-wise up- or downregulation of gene expression simultaneously for multiple lists of genes (gene sets against entire distributions of gene expression changes (datasets for single or multiple experiments. The utility of GSMA lies in its flexibility to rapidly poll gene sets related by known biological function or as designated solely by the end-user against large numbers of datasets simultaneously.Conclusions: GSMA provides a simple and straightforward method for hypothesis testing in which genes are tested by groups across multiple datasets for patterns of expression enrichment.

  6. Monte Carlo based, patient-specific RapidArc QA using Linac log files

    Energy Technology Data Exchange (ETDEWEB)

    Teke, Tony; Bergman, Alanah M.; Kwa, William; Gill, Bradford; Duzenli, Cheryl; Popescu, I. Antoniu [Physics and Astronomy, University of British Columbia, Vancouver, British Columbia V6T 1Z1 (Canada); Medical Physics, BC Cancer Agency-Vancouver Centre, Vancouver, British Columbia V5Z 4E6 (Canada)

    2010-01-15

    Purpose: A Monte Carlo (MC) based QA process to validate the dynamic beam delivery accuracy for Varian RapidArc (Varian Medical Systems, Palo Alto, CA) using Linac delivery log files (DynaLog) is presented. Using DynaLog file analysis and MC simulations, the goal of this article is to (a) confirm that adequate sampling is used in the RapidArc optimization algorithm (177 static gantry angles) and (b) to assess the physical machine performance [gantry angle and monitor unit (MU) delivery accuracy]. Methods: Ten clinically acceptable RapidArc treatment plans were generated for various tumor sites and delivered to a water-equivalent cylindrical phantom on the treatment unit. Three Monte Carlo simulations were performed to calculate dose to the CT phantom image set: (a) One using a series of static gantry angles defined by 177 control points with treatment planning system (TPS) MLC control files (planning files), (b) one using continuous gantry rotation with TPS generated MLC control files, and (c) one using continuous gantry rotation with actual Linac delivery log files. Monte Carlo simulated dose distributions are compared to both ionization chamber point measurements and with RapidArc TPS calculated doses. The 3D dose distributions were compared using a 3D gamma-factor analysis, employing a 3%/3 mm distance-to-agreement criterion. Results: The dose difference between MC simulations, TPS, and ionization chamber point measurements was less than 2.1%. For all plans, the MC calculated 3D dose distributions agreed well with the TPS calculated doses (gamma-factor values were less than 1 for more than 95% of the points considered). Machine performance QA was supplemented with an extensive DynaLog file analysis. A DynaLog file analysis showed that leaf position errors were less than 1 mm for 94% of the time and there were no leaf errors greater than 2.5 mm. The mean standard deviation in MU and gantry angle were 0.052 MU and 0.355 deg., respectively, for the ten cases

  7. Notch stress intensity factors under mixed mode loadings: an overview of recent advanced methods for rapid calculation

    Directory of Open Access Journals (Sweden)

    M. Peron

    2017-10-01

    Full Text Available Recently some methods for the rapid calculation of notch stress intensity factors (NSIFs have been developed and three of them are compared in this work. First, the criteria proposed by Lazzarin et al. and Treifi et al. have been reviewed. The former is based on the calculation of the mean value of SED on two different control volume (characterized by two different radius values centred at the stress singularity point, whereas the latter takes advantage of the strain energy density averaged within two control volumes (semi-circular sector centred at the notch tip. Then, a new method based on the evaluation of the total and deviatoric SED averaged in a single control volume has been proposed. Finally, plate specimens weakened by different notch geometries have been subjected to the application of the above mentioned methods and the obtained values of the NSIFs have been compared with those derived according to Gross and Mendelson

  8. Rapid deletion-based subtyping system for the Manila family of Mycobacterium tuberculosis.

    Science.gov (United States)

    Frink, Stephen; Qian, Lishi; Yu, Steven; Cruz, Laura; Desmond, Ed; Douglas, James T

    2011-05-01

    The Manila family of Mycobacterium tuberculosis is a group of clonal isolates seen throughout the Pacific Basin. Commonly used rapid molecular typing methods often leave large groups of Manila family isolates clustered together. Here we describe a simple deletion-based PCR method that improves the discrimination for Manila family isolates, with or without the use of mycobacterial interspersed repetitive-unit-variable-number tandem-repeat (MIRU-VNTR) classification, and that is both rapid and affordable. Twenty-eight Manila family isolates, classified by spoligotyping, were collected from around the Pacific Basin from 1995 to 2003 and were tested for known genomic deletions. Nine of 15 regions of difference tested were identified as potentially discriminatory, with 18 distinct patterns; of these 9, 5 were selected for optimal discrimination using 61 Manila family isolates collected from California in 2009. For this geographically limited sample, the single large cluster was reduced to 14 distinct patterns. When the isolates were tested by spoligotyping and MIRU-VNTR, the addition of deletion analysis increased the number of distinct patterns from 43 to 56. In summary, the two study groups, which together form a single group of 89 isolates by spoligotyping, were segregated into 17 subgroups by our deletion-based subtyping system.

  9. Rapid Detection Technology for Pesticides Residues Based on Microelectrodes Impedance Immunosensor

    Directory of Open Access Journals (Sweden)

    Wen Ping Zhao

    2014-09-01

    Full Text Available Compared with conventional methods, electrochemical immunosensors have many advantages, such as low cost, high sensitivity, and rapid detection, and has certain prospects for realizing real-time-monitoring. In this paper, a design of portable pesticide residues detection instrument was presented based on an electrochemical impedance immunosensor. Firstly, we studied on an impedance immunosensor based on interdigitated array microelectrode (IDAM coupled with magnetic nanobeads-antibody conjugates (MNAC for the pesticide detection. Magnetic nanobeads (diameter 150 nm coated with anti-carbofuran antibodies were used for further amplification of the binding reaction between antibody and hapten (carbofuran. Secondly, in order to develop a portable pesticide residue apparatus, we designed the impedance detection electric circuit. Main work included designing and constructing of the system circuit, designing and debugging of the system software and so on. Thirdly, the apparatus was used for the standard pesticides solutions testing combined with immunosensor to test the reliability and stability. The pesticide added standard recovery was more than 70 % and the impedance test error was less than 5 %. The results showed that the proposed instrument had a good consistence compared with the traditional analytical methods. Thus, it would be a promising rapid detection instrument for pesticide residues in agricultural products.

  10. Rapid Determination of Isomeric Benzoylpaeoniflorin and Benzoylalbiflorin in Rat Plasma by LC-MS/MS Method

    Directory of Open Access Journals (Sweden)

    Chuanqi Zhou

    2017-01-01

    Full Text Available Benzoylpaeoniflorin (BP is a potential therapeutic agent against oxidative stress related Alzheimer’s disease. In this study, a more rapid, selective, and sensitive liquid chromatography-tandem mass spectrometric (LC-MS/MS method was developed to determine BP in rat plasma distinguishing with a monoterpene isomer, benzoylalbiflorin (BA. The method showed a linear response from 1 to 1000 ng/mL (r>0.9950. The precision of the interday and intraday ranged from 2.03 to 12.48% and the accuracy values ranged from −8.00 to 10.33%. Each running of the method could be finished in 4 minutes. The LC-MS/MS method was validated for specificity, linearity, precision, accuracy, recovery, and stability and was found to be acceptable for bioanalytical application. Finally, this fully validated method was successfully applied to a pharmacokinetic study in rats following oral administration.

  11. A Microfluidic Channel Method for Rapid Drug-Susceptibility Testing of Pseudomonas aeruginosa

    Science.gov (United States)

    Matsumoto, Yoshimi; Grushnikov, Andrey; Kikuchi, Kazuma; Noji, Hiroyuki; Yamaguchi, Akihito; Yagi, Yasushi

    2016-01-01

    The recent global increase in the prevalence of antibiotic-resistant bacteria and lack of development of new therapeutic agents emphasize the importance of selecting appropriate antimicrobials for the treatment of infections. However, to date, the development of completely accelerated drug susceptibility testing methods has not been achieved despite the availability of a rapid identification method. We proposed an innovative rapid method for drug susceptibility testing for Pseudomonas aeruginosa that provides results within 3 h. The drug susceptibility testing microfluidic (DSTM) device was prepared using soft lithography. It consisted of five sets of four microfluidic channels sharing one inlet slot, and the four channels are gathered in a small area, permitting simultaneous microscopic observation. Antimicrobials were pre-introduced into each channel and dried before use. Bacterial suspensions in cation-adjusted Mueller–Hinton broth were introduced from the inlet slot and incubated for 3 h. Susceptibilities were microscopically evaluated on the basis of differences in cell numbers and shapes between drug-treated and control cells, using dedicated software. The results of 101 clinically isolated strains of P. aeruginosa obtained using the DSTM method strongly correlated with results obtained using the ordinary microbroth dilution method. Ciprofloxacin, meropenem, ceftazidime, and piperacillin caused elongation in susceptible cells, while meropenem also induced spheroplast and bulge formation. Morphological observation could alternatively be used to determine the susceptibility of P. aeruginosa to these drugs, although amikacin had little effect on cell shape. The rapid determination of bacterial drug susceptibility using the DSTM method could also be applicable to other pathogenic species, and it could easily be introduced into clinical laboratories without the need for expensive instrumentation. PMID:26872134

  12. A Microfluidic Channel Method for Rapid Drug-Susceptibility Testing of Pseudomonas aeruginosa.

    Directory of Open Access Journals (Sweden)

    Yoshimi Matsumoto

    Full Text Available The recent global increase in the prevalence of antibiotic-resistant bacteria and lack of development of new therapeutic agents emphasize the importance of selecting appropriate antimicrobials for the treatment of infections. However, to date, the development of completely accelerated drug susceptibility testing methods has not been achieved despite the availability of a rapid identification method. We proposed an innovative rapid method for drug susceptibility testing for Pseudomonas aeruginosa that provides results within 3 h. The drug susceptibility testing microfluidic (DSTM device was prepared using soft lithography. It consisted of five sets of four microfluidic channels sharing one inlet slot, and the four channels are gathered in a small area, permitting simultaneous microscopic observation. Antimicrobials were pre-introduced into each channel and dried before use. Bacterial suspensions in cation-adjusted Mueller-Hinton broth were introduced from the inlet slot and incubated for 3 h. Susceptibilities were microscopically evaluated on the basis of differences in cell numbers and shapes between drug-treated and control cells, using dedicated software. The results of 101 clinically isolated strains of P. aeruginosa obtained using the DSTM method strongly correlated with results obtained using the ordinary microbroth dilution method. Ciprofloxacin, meropenem, ceftazidime, and piperacillin caused elongation in susceptible cells, while meropenem also induced spheroplast and bulge formation. Morphological observation could alternatively be used to determine the susceptibility of P. aeruginosa to these drugs, although amikacin had little effect on cell shape. The rapid determination of bacterial drug susceptibility using the DSTM method could also be applicable to other pathogenic species, and it could easily be introduced into clinical laboratories without the need for expensive instrumentation.

  13. Development of rapid methods for relaxation time mapping and motion estimation using magnetic resonance imaging

    OpenAIRE

    Gilani, Syed Irtiza Ali

    2008-01-01

    Recent technological developments in the field of magnetic resonance imaging have resulted in advanced techniques that can reduce the total time to acquire images. For applications such as relaxation time mapping, which enables improved visualisation of in vivo structures, rapid imaging techniques are highly desirable. TAPIR is a Look- Locker-based sequence for high-resolution, multislice T1 relaxation time mapping. Despite the high accuracy and precision of TAPIR, an improveme...

  14. A computer-based matrix for rapid calculation of pulmonary hemodynamic parameters in congenital heart disease

    Directory of Open Access Journals (Sweden)

    Lopes Antonio

    2009-01-01

    Full Text Available Background : In patients with congenital heart disease undergoing cardiac catheterization for hemodynamic purposes, parameter estimation by the indirect Fick method using a single predicted value of oxygen consumption has been a matter of criticism. Objective : We developed a computer-based routine for rapid estimation of replicate hemodynamic parameters using multiple predicted values of oxygen consumption. Materials and Methods : Using Microsoft ® Excel facilities, we constructed a matrix containing 5 models (equations for prediction of oxygen consumption, and all additional formulas needed to obtain replicate estimates of hemodynamic parameters. Results : By entering data from 65 patients with ventricular septal defects, aged 1 month to 8 years, it was possible to obtain multiple predictions for oxygen consumption, with clear between-age groups ( P < .001 and between-methods ( P < .001 differences. Using these predictions in the individual patient, it was possible to obtain the upper and lower limits of a likely range for any given parameter, which made estimation more realistic. Conclusion : The organized matrix allows for rapid obtainment of replicate parameter estimates, without error due to exhaustive calculations.

  15. Adjustment of a rapid method for quantification of Fusarium spp. spore suspensions in plant pathology.

    Science.gov (United States)

    Caligiore-Gei, Pablo F; Valdez, Jorge G

    2015-01-01

    The use of a Neubauer chamber is a broadly employed method when cell suspensions need to be quantified. However, this technique may take a long time and needs trained personnel. Spectrophotometry has proved to be a rapid, simple and accurate method to estimate the concentration of spore suspensions of isolates of the genus Fusarium. In this work we present a linear formula to relate absorbance measurements at 530nm with the number of microconidia/ml in a suspension. Copyright © 2014 Asociación Argentina de Microbiología. Publicado por Elsevier España, S.L.U. All rights reserved.

  16. Rapid method for protein quantitation by Bradford assay after elimination of the interference of polysorbate 80.

    Science.gov (United States)

    Cheng, Yongfeng; Wei, Haiming; Sun, Rui; Tian, Zhigang; Zheng, Xiaodong

    2016-02-01

    Bradford assay is one of the most common methods for measuring protein concentrations. However, some pharmaceutical excipients, such as detergents, interfere with Bradford assay even at low concentrations. Protein precipitation can be used to overcome sample incompatibility with protein quantitation. But the rate of protein recovery caused by acetone precipitation is only about 70%. In this study, we found that sucrose not only could increase the rate of protein recovery after 1 h acetone precipitation, but also did not interfere with Bradford assay. So we developed a method for rapid protein quantitation in protein drugs even if they contained interfering substances. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Comparison of the NIDS® rapid assay with ELISA methods in immunogenicity testing of two biotherapeutics.

    Science.gov (United States)

    Pan, Jing; Small, Thomas; Qin, Dujie; Li, Shawn; Wang, Li; Chen, Dave; Pauley, Cindy; Verch, Thorsten; Kaplanski, Catherine; Bakhtiar, Ray; Vallejo, Yli Remo; Yin, Ray

    2011-01-01

    Rapid lateral flow immunogenicity assays for the detection of anti-drug antibodies (ADAs) to two biotherapeutic antibodies, an anti-HER2 antibody and an anti-TNF-α antibody, were developed using ANP Technologies, Inc.'s proprietary Nano-Intelligent Detection System (NIDS®) and compared to their ELISA counterparts. Biotin and hapten-labeled drugs are incubated with the patient serum sample to allow ADA to form a bridge complex with each drug conjugate. The reaction mixture is then added to a test strip with an anti-hapten capture zone which captures the mixed bridge complex. The bridge-complexed biotinylated drug then reacts with streptavidin-labeled gold particles in situ. The signal developed at the capture zone, which is directly proportional to ADA in the sample, is then quantitatively measured with a handheld reader. The counterpart ELISAs were run using the same reagents. Dose-response, specificity/free drug depletion, and screening cut-point assays were performed using both methods. The rapid assays' performance compare very closely to their ELISA counterparts'. Both types of assays identified the same positive samples in screening a limited population of 50 normal serum samples for the anti-HER2 antibody. In the case of anti-TNF-α, both assays identified the same positive samples out of 50 normal and 20 rheumatoid arthritis patient serum samples but differed in the assessment of two others. The rapid assay correctly identified as negative an ELISA false positive sample, and correctly tested as positive an ELISA false negative sample. Positive results were verified with a specificity/free drug depletion assay. The NIDS® rapid immunogenicity assay offers distinct advantages over current methods in simplicity, low cost, and short time to result. More importantly, the method requires no sample dilution and no washing steps which can perturb fragile complexes formed by low-affinity ADAs. Thus, the assay can potentially detect ADAs with various affinities

  18. Adaptive Channel-Tracking Method and Equalization for MC-CDMA Systems over Rapidly Fading Channel under Colored Noise

    Directory of Open Access Journals (Sweden)

    Chen Bor-Sen

    2010-01-01

    Full Text Available A recursive maximum-likelihood (RML algorithm for channel estimation under rapidly fading channel and colored noise in a multicarrier code-division multiple-access (MC-CDMA system is proposed in this paper. A moving-average model with exogenous input (MAX is given to describe the transmission channel and colored noise. Based on the pseudoregression method, the proposed RML algorithm can simultaneously estimate the parameters of channel and colored noise. Following the estimation results, these parameters can be used to enhance the minimum mean-square error (MMSE equalizer. Considering high-speed mobile stations, a one-step linear trend predictor is added to improve symbol detection. Simulation results indicate that the proposed RML estimator can track the channel more precisely than the conventional estimator. Meanwhile, the performance of the proposed enhanced MMSE equalizer is robust to the rapidly Rayleigh fading channel under colored noise in the MC-CDMA systems.

  19. Adaptive Channel-Tracking Method and Equalization for MC-CDMA Systems over Rapidly Fading Channel under Colored Noise

    Science.gov (United States)

    Yang, Chang-Yi; Chen, Bor-Sen

    2010-12-01

    A recursive maximum-likelihood (RML) algorithm for channel estimation under rapidly fading channel and colored noise in a multicarrier code-division multiple-access (MC-CDMA) system is proposed in this paper. A moving-average model with exogenous input (MAX) is given to describe the transmission channel and colored noise. Based on the pseudoregression method, the proposed RML algorithm can simultaneously estimate the parameters of channel and colored noise. Following the estimation results, these parameters can be used to enhance the minimum mean-square error (MMSE) equalizer. Considering high-speed mobile stations, a one-step linear trend predictor is added to improve symbol detection. Simulation results indicate that the proposed RML estimator can track the channel more precisely than the conventional estimator. Meanwhile, the performance of the proposed enhanced MMSE equalizer is robust to the rapidly Rayleigh fading channel under colored noise in the MC-CDMA systems.

  20. Development of a Rapid Cell-free Method for Cytotoxicity Assessment of Vapor Phase of Cigarette Smoke

    Directory of Open Access Journals (Sweden)

    Cahours X

    2014-12-01

    Full Text Available Currently, several in vitro tests are widely used to measure toxicological properties of mainstream smoke (Neutral Red Uptake Assay, Micronucleus assay, Ames Test. These tests are necessary to assess cytotoxicity, genotoxicity, and mutagenicity, but are time consuming. This is essentially due to the preparation and the handling of cells. It is difficult to use these in vitro tests as screening method for product testing and development. For a better assessment of the cytotoxicity of the vapor phase, a rapid cell-free method has been developed. This paper describes a capillary electrophoresis cell-free method, based on the depletion of an anti-oxidant L-gamma-glutamyl-L-cysteinylglycine (GSH, applied to an aliquot of vapor phase phosphate buffered saline (PBS-trapped cigarette smoke (as recommended for in vitro testing. The correlation between this method and the survival/viability test (Neutral Red cytotoxicity is excellent (coefficient of correlation (r = 0.99.

  1. [Computer-aided method and rapid prototyping for the personalized fabrication of a silicone bandage digital prosthesis].

    Science.gov (United States)

    Ventura Ferreira, Nuno; Leal, Nuno; Correia Sá, Inês; Reis, Ana; Marques, Marisa

    2014-01-01

    The fabrication of digital prostheses has acquired growing importance not only for the possibility for the patient to overcome psychosocial trauma but also to promote grip functionality. An application method of three dimensional-computer-aided design technologies for the production of passive prostheses is presented by means of a fifth finger amputee clinical case following bilateral hand replantation.Three-dimensional-computerized tomography was used for the collection of anthropometric images of the hands. Computer-aided design techniques were used to develop the digital file-based prosthesis from the reconstruction images by inversion and superimposing the contra-lateral finger images. The rapid prototyping manufacturing method was used for the production of a silicone bandage prosthesis prototype. This approach replaces the traditional manual method by a virtual method that is basis for the optimization of a high speed, accurate and innovative process.

  2. Development of a rapid diagnostic method for identification of Staphylococcus aureus and antimicrobial resistance in positive blood culture bottles using a PCR-DNA-chromatography method.

    Science.gov (United States)

    Ohshiro, Takeya; Miyagi, Chihiro; Tamaki, Yoshikazu; Mizuno, Takuya; Ezaki, Takayuki

    2016-06-01

    Blood culturing and the rapid reporting of results are essential for infectious disease clinics to obtain bacterial information that can affect patient prognosis. When gram-positive coccoid cells are observed in blood culture bottles, it is important to determine whether the strain is Staphylococcus aureus and whether the strain has resistance genes, such as mecA and blaZ, for proper antibiotic selection. Previous work led to the development of a PCR method that is useful for rapid identification of bacterial species and antimicrobial susceptibility. However, that method has not yet been adopted in community hospitals due to the high cost and methodological complexity. We report here the development of a quick PCR and DNA-chromatography test, based on single-tag hybridization chromatography, that permits detection of S. aureus and the mecA and blaZ genes; results can be obtained within 1 h for positive blood culture bottles. We evaluated this method using 42 clinical isolates. Detection of S. aureus and the resistance genes by the PCR-DNA-chromatography method was compared with that obtained via the conventional identification method and actual antimicrobial susceptibility testing. Our method had a sensitivity of 97.0% and a specificity of 100% for the identification of the bacterial species. For the detection of the mecA gene of S. aureus, the sensitivity was 100% and the specificity was 95.2%. For the detection of the blaZ gene of S. aureus, the sensitivity was 100% and the specificity was 88.9%. The speed and simplicity of this PCR-DNA-chromatography method suggest that our method will facilitate rapid diagnoses. Copyright © 2016 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  3. Flow cytometry based rapid duplexed immunoassay for fusarium mycotoxins.

    Science.gov (United States)

    Czéh, Árpád; Mézes, Miklós; Mandy, Francis; Szőke, Zsuzsanna; Nagyéri, György; Laufer, Noémi; Kőszegi, Balázs; Koczka, Tamás; Kunsági-Máté, Sándor; Lustyik, György

    2017-02-01

    At small food processing facilities, the most frequently used test to determine if grain-derived mycotoxin concentrations are compliant with legal limits is the enzyme-linked immunosorbent assay (ELISA). Each kit is designed to detect one of the six dangerous mycotoxins. With the increasing occurrence of coinfection of grain with multiple-mycotoxins in the field and/or during storage, ELISA is no longer a cost effective best assay option. With ELISA, each species of mycotoxin requires different sample preparation/extraction and a 45 min incubation. The alternative multiplexed assay presented here, the competitive fluorescent microsphere immunoassay (CFIA), follows current food safety standards. It handles several toxins simultaneously with a single universal extraction protocol. The authors' objective was to modify an existing commercial CFIA kit developed for bench top flow cytometry and extend its utility for point-of-need (PON) applications. The accelerated protocol offers over 60% reduction in total processing time and it detects dual mycotoxin contamination simultaneously. The observed enhanced binding kinetics equations reported here utilizing suspended solid phase particles in liquid phase, are also supported by published theoretical calculations. In the near future portable cytometry may bring rapid multiplexed PON testing to assure the safety of small food processing installations. © 2016 International Society for Advancement of Cytometry. © 2016 International Society for Advancement of Cytometry.

  4. Pheromones-based sexual selection in a rapidly changing world.

    Science.gov (United States)

    Henneken, Jessica; Jones, Therésa M

    2017-12-01

    Insects utilise chemical cues for a range of different purposes and the complexity and degree of specificity of these signals is arguably unparalleled in the animal kingdom. Chemical signals are particularly important for insect reproduction and the selective pressures driving their evolution and maintenance have been the subject of previous reviews. However, the world in which chemical cues evolved and are maintained is changing at an unprecedented rate. How (or indeed whether) chemical signals used in sexual selection will respond is largely unknown. Here, we explore how recent increases in urbanisation and associated anthropogenic impacts may affect how chemical signals are produced and perceived. We focus on four anthropomorphic influences which have the potential to interact with pheromone-mediated sexual selection processes; climatic temperature shifts, exposure to chemical pollutants, the presence of artificial light at night and nutrient availability. Our aim is to provide a broad overview of key areas where the rapidly changing environment of the future might specifically affect pheromones utilised in sexual selection. Copyright © 2017. Published by Elsevier Inc.

  5. An asymmetric PCR-based, reliable and rapid single-tube native DNA engineering strategy

    Directory of Open Access Journals (Sweden)

    Bi Yanzhen

    2012-07-01

    Full Text Available Abstract Background Widely used restriction-dependent cloning methods are labour-intensive and time-consuming, while several types of ligase-independent cloning approaches have inherent limitations. A rapid and reliable method of cloning native DNA sequences into desired plasmids are highly desired. Results This paper introduces ABI-REC, a novel strategy combining asymmetric bridge PCR with intramolecular homologous recombination in bacteria for native DNA cloning. ABI-REC was developed to precisely clone inserts into defined location in a directional manner within recipient plasmids. It featured an asymmetric 3-primer PCR performed in a single tube that could robustly amplify a chimeric insert-plasmid DNA sequence with homologous arms at both ends. Intramolecular homologous recombination occurred to the chimera when it was transformed into E.coli and produced the desired recombinant plasmids with high efficiency and fidelity. It is rapid, and does not involve any operational nucleotides. We proved the reliability of ABI-REC using a double-resistance reporter assay, and investigated the effects of homology and insert length upon its efficiency. We found that 15 bp homology was sufficient to initiate recombination, while 25 bp homology had the highest cloning efficiency. Inserts up to 4 kb in size could be cloned by this method. The utility and advantages of ABI-REC were demonstrated through a series of pig myostatin (MSTN promoter and terminator reporter plasmids, whose transcriptional activity was assessed in mammalian cells. We finally used ABI-REC to construct a pig MSTN promoter-terminator cassette reporter and showed that it could work coordinately to express EGFP. Conclusions ABI-REC has the following advantages: (i rapid and highly efficient; (ii native DNA cloning without introduction of extra bases; (iii restriction-free; (iv easy positioning of directional and site-specific recombination owing to formulated primer design. ABI

  6. An asymmetric PCR-based, reliable and rapid single-tube native DNA engineering strategy.

    Science.gov (United States)

    Bi, Yanzhen; Qiao, Xianfeng; Hua, Zaidong; Zhang, Liping; Liu, Ximei; Li, Li; Hua, Wenjun; Xiao, Hongwei; Zhou, Jingrong; Wei, Qingxin; Zheng, Xinmin

    2012-07-06

    Widely used restriction-dependent cloning methods are labour-intensive and time-consuming, while several types of ligase-independent cloning approaches have inherent limitations. A rapid and reliable method of cloning native DNA sequences into desired plasmids are highly desired. This paper introduces ABI-REC, a novel strategy combining asymmetric bridge PCR with intramolecular homologous recombination in bacteria for native DNA cloning. ABI-REC was developed to precisely clone inserts into defined location in a directional manner within recipient plasmids. It featured an asymmetric 3-primer PCR performed in a single tube that could robustly amplify a chimeric insert-plasmid DNA sequence with homologous arms at both ends. Intramolecular homologous recombination occurred to the chimera when it was transformed into E.coli and produced the desired recombinant plasmids with high efficiency and fidelity. It is rapid, and does not involve any operational nucleotides. We proved the reliability of ABI-REC using a double-resistance reporter assay, and investigated the effects of homology and insert length upon its efficiency. We found that 15 bp homology was sufficient to initiate recombination, while 25 bp homology had the highest cloning efficiency. Inserts up to 4 kb in size could be cloned by this method. The utility and advantages of ABI-REC were demonstrated through a series of pig myostatin (MSTN) promoter and terminator reporter plasmids, whose transcriptional activity was assessed in mammalian cells. We finally used ABI-REC to construct a pig MSTN promoter-terminator cassette reporter and showed that it could work coordinately to express EGFP. ABI-REC has the following advantages: (i) rapid and highly efficient; (ii) native DNA cloning without introduction of extra bases; (iii) restriction-free; (iv) easy positioning of directional and site-specific recombination owing to formulated primer design. ABI-REC is a novel approach to DNA engineering and gene functional

  7. A Rapid and Reliable Method for Total Protein Extraction from Succulent Plants for Proteomic Analysis.

    Science.gov (United States)

    Lledías, Fernando; Hernández, Felipe; Rivas, Viridiana; García-Mendoza, Abisaí; Cassab, Gladys I; Nieto-Sotelo, Jorge

    2017-08-01

    Crassulacean acid metabolism plants have some morphological features, such as succulent and reduced leaves, thick cuticles, and sunken stomata that help them prevent excessive water loss and irradiation. As molecular constituents of these morphological adaptations to xeric environments, succulent plants produce a set of specific compounds such as complex polysaccharides, pigments, waxes, and terpenoids, to name a few, in addition to uncharacterized proteases. Since all these compounds interfere with the analysis of proteins by electrophoretic techniques, preparation of high quality samples from these sources represents a real challenge. The absence of adequate protocols for protein extraction has restrained the study of this class of plants at the molecular level. Here, we present a rapid and reliable protocol that could be accomplished in 1 h and applied to a broad range of plants with reproducible results. We were able to obtain well-resolved SDS/PAGE protein patterns in extracts from different members of the subfamilies Agavoideae (Agave, Yucca, Manfreda, and Furcraea), Nolinoideae (Dasylirion and Beucarnea), and the Cactaceae family. This method is based on the differential solubility of contaminants and proteins in the presence of acetone and pH-altered solutions. We speculate about the role of saponins and high molecular weight carbohydrates to produce electrophoretic-compatible samples. A modification of the basic protocol allowed the analysis of samples by bidimensional electrophoresis (2DE) for proteomic analysis. Furostanol glycoside 26-O-β-glucosidase (an enzyme involved in steroid saponin synthesis) was successfully identified by mass spectrometry analysis and de novo sequencing of a 2DE spot from an Agave attenuata sample.

  8. Amniotic fluid volume: Rapid MR-based assessment at 28-32 weeks gestation

    Energy Technology Data Exchange (ETDEWEB)

    Hilliard, N.J.; Hawkes, R.; Patterson, A.J.; Graves, M.J.; Priest, A.N.; Hunter, S.; Set, P.A.; Lomas, D.J. [Cambridge University Hospitals NHS Foundation Trust, Department of Radiology, Cambridge (United Kingdom); Lees, C. [Imperial College Healthcare NHS Trust, Department of Obstetrics and Fetal Medicine, London (United Kingdom)

    2016-10-15

    This work evaluates rapid magnetic resonance projection hydrography (PH) based amniotic fluid volume (AFV) estimates against established routine ultrasound single deepest vertical pocket (SDVP) and amniotic fluid index (AFI) measurements, in utero at 28-32 weeks gestation. Manual multi-section planimetry (MSP) based measurement of AFV is used as a proxy reference standard. Thirty-five women with a healthy singleton pregnancy (20-41 years) attending routine antenatal ultrasound were recruited. SDVP and AFI were measured using ultrasound, with same day MRI assessing AFV with PH and MSP. The relationships between the respective techniques were assessed using linear regression analysis and Bland-Altman method comparison statistics. When comparing estimated AFV, a highly significant relationship was observed between PH and the reference standard MSP (R{sup 2} = 0.802, p < 0.001). For the US measurements, SDVP measurement related most closely to amniotic fluid volume, (R{sup 2} = 0.470, p < 0.001), with AFI demonstrating a weaker relationship (R{sup 2} = 0.208, p = 0.007). This study shows that rapid MRI based PH measurement is a better predictor of AFV, relating more closely to our proxy standard than established US techniques. Although larger validation studies across a range of gestational ages are required this approach could form part of MR fetal assessment, particularly where poly- or oligohydramnios is suspected. (orig.)

  9. Bioactive Paper Sensor Based on the Acetylcholinesterase for the Rapid Detection of Organophosphate and Carbamate Pesticides

    Directory of Open Access Journals (Sweden)

    Mohamed E. I. Badawy

    2014-01-01

    Full Text Available In many countries, people are becoming more concerned about pesticide residues which are present in or on food and feed products. For this reason, several methods have been developed to monitor the pesticide residue levels in food samples. In this study, a bioactive paper-based sensor was developed for detection of acetylcholinesterase (AChE inhibitors including organophosphate and carbamate pesticides. Based on the Ellman colorimetric assay, the assay strip is composed of a paper support (1×10 cm, onto which a biopolymer chitosan gel immobilized in crosslinking by glutaraldehyde with AChE and 5,5′-dithiobis(2-nitrobenzoic acid (DTNB and uses acetylthiocholine iodide (ATChI as an outside reagent. The assay protocol involves introducing the sample to sensing zone via dipping of a pesticide-containing solution. Following an incubation period, the paper is placed into ATChI solution to initiate enzyme catalyzed hydrolysis of the substrate, causing a yellow color change. The absence or decrease of the yellow color indicates the levels of the AChE inhibitors. The biosensor is able to detect organophosphate and carbamate pesticides with good detection limits (methomyl=6.16×10-4 mM and profenofos=0.27 mM and rapid response times (~5 min. The results show that the paper-based biosensor is rapid, sensitive, inexpensive, portable, disposable, and easy-to-use.

  10. New modelling method for fast reactor neutronic behaviours analysis; Nouvelles methodes de modelisation neutronique des reacteurs rapides de quatrieme Generation

    Energy Technology Data Exchange (ETDEWEB)

    Jacquet, P.

    2011-05-23

    Due to safety rules running on fourth generation reactors' core development, neutronics simulation tools have to be as accurate as never before. First part of this report enumerates every step of fast reactor's neutronics simulation implemented in current reference code: ECCO. Considering the field of fast reactors that meet criteria of fourth generation, ability of models to describe self-shielding phenomenon, to simulate neutrons leakage in a lattice of fuel assemblies and to produce representative macroscopic sections is evaluated. The second part of this thesis is dedicated to the simulation of fast reactors' core with steel reflector. These require the development of advanced methods of condensation and homogenization. Several methods are proposed and compared on a typical case: the ZONA2B core of MASURCA reactor. (author) [French] Les criteres de surete qui regissent le developpement de coeurs de reacteurs de quatrieme generation implique l'usage d'outils de calcul neutronique performants. Une premiere partie de la these reprend toutes les etapes de modelisation neutronique des reacteurs rapides actuellement d'usage dans le code de reference ECCO. La capacite des modeles a decrire le phenomene d'autoprotection, a representer les fuites neutroniques au niveau d'un reseau d'assemblages combustibles et a generer des sections macroscopiques representatives est appreciee sur le domaine des reacteurs rapides innovants respectant les criteres de quatrieme generation. La deuxieme partie de ce memoire se consacre a la modelisation des coeurs rapides avec reflecteur acier. Ces derniers necessitent le developpement de methodes avancees de condensation et d'homogenisation. Plusieurs methodes sont proposees et confrontees sur un probleme de modelisation typique: le coeur ZONA2B du reacteur maquette MASURCA

  11. Rapid methods to detect organic mercury and total selenium in biological samples

    Directory of Open Access Journals (Sweden)

    Basu Niladri

    2011-01-01

    Full Text Available Abstract Background Organic mercury (Hg is a global pollutant of concern and selenium is believed to afford protection against mercury risk though few approaches exist to rapidly assess both chemicals in biological samples. Here, micro-scale and rapid methods to detect organic mercury ( Results For organic Hg, samples are digested using Tris-HCl buffer (with sequential additions of protease, NaOH, cysteine, CuSO4, acidic NaBr followed by extraction with toluene and Na2S2O3. The final product is analyzed via commercially available direct/total mercury analyzers. For Se, a fluorometric assay has been developed for microplate readers that involves digestion (HNO3-HClO4 and HCl, conjugation (2,3-diaminonaphthalene, and cyclohexane extraction. Recovery of organic Hg (86-107% and Se (85-121% were determined through use of Standard Reference Materials and lemon shark kidney tissues. Conclusions The approaches outlined provide an easy, rapid, reproducible, and cost-effective platform for monitoring organic Hg and total Se in biological samples. Owing to the importance of organic Hg and Se in the pathophysiology of Hg, integration of such methods into established research monitoring efforts (that largely focus on screening total Hg only will help increase understanding of Hg's true risks.

  12. Chapter 11. Community analysis-based methods

    Energy Technology Data Exchange (ETDEWEB)

    Cao, Y.; Wu, C.H.; Andersen, G.L.; Holden, P.A.

    2010-05-01

    Microbial communities are each a composite of populations whose presence and relative abundance in water or other environmental samples are a direct manifestation of environmental conditions, including the introduction of microbe-rich fecal material and factors promoting persistence of the microbes therein. As shown by culture-independent methods, different animal-host fecal microbial communities appear distinctive, suggesting that their community profiles can be used to differentiate fecal samples and to potentially reveal the presence of host fecal material in environmental waters. Cross-comparisons of microbial communities from different hosts also reveal relative abundances of genetic groups that can be used to distinguish sources. In increasing order of their information richness, several community analysis methods hold promise for MST applications: phospholipid fatty acid (PLFA) analysis, denaturing gradient gel electrophoresis (DGGE), terminal restriction fragment length polymorphism (TRFLP), cloning/sequencing, and PhyloChip. Specific case studies involving TRFLP and PhyloChip approaches demonstrate the ability of community-based analyses of contaminated waters to confirm a diagnosis of water quality based on host-specific marker(s). The success of community-based MST for comprehensively confirming fecal sources relies extensively upon using appropriate multivariate statistical approaches. While community-based MST is still under evaluation and development as a primary diagnostic tool, results presented herein demonstrate its promise. Coupled with its inherently comprehensive ability to capture an unprecedented amount of microbiological data that is relevant to water quality, the tools for microbial community analysis are increasingly accessible, and community-based approaches have unparalleled potential for translation into rapid, perhaps real-time, monitoring platforms.

  13. Application of rapid cloud point extraction method for trace cobalt analysis coupled with spectrophotometric determination

    Science.gov (United States)

    Wen, Xiaodong; He, Lei; Shi, Chunsheng; Deng, Qingwen; Wang, Jiwei; Zhao, Xia

    2013-11-01

    In this work, the analytical performance of conventional spectrophotometer was improved through the coupling of effective preconcentration method with spectrophotometric determination. Rapidly synergistic cloud point extraction (RS-CPE) was used to pre-concentrate ultra trace cobalt and firstly coupled with spectrophotometric determination. The developed coupling was simple, rapid and efficient. The factors influencing RS-CPE and spectrophotometer were optimized. Under the optimal conditions, the limit of detection (LOD) was 0.6 μg L-1, with sensitivity enhancement factor of 23. The relative standard deviation (RSD) for seven replicate measurements of 50 μg L-1 of cobalt was 4.3%. The recoveries for the spiked samples were in the acceptable range of 93.8-105%.

  14. [Three-Iindex-Value Method for Rapid Screening Unqualified Vegetable Oil].

    Science.gov (United States)

    He, Wen-xuan; Hong, Gui-shui; Fang, Run; Cai, Xian-chun; Huang, Sheng

    2015-04-01

    In the present study, by measuring the A3 005 (representing unsaturation), A985 (representing conjugated fatty acids), A960 + A985 (representing trans-fatty acid ) of southern common vegetable oils (peanut oil, corn oil, canola oil, soybean oil, sunflower oil, tea seed oil and olive oil), "waste oil" and overdue vegetable oils, the pass-setting-range of these three index values for the vegetable oils was obtained. On this basis, a method for rapid screening unqualified vegetable oil (expired, adding low-cost oil, adding "waste oil") was established. The method effectively improved the monitoring efficiency of vegetable oil. With this method of screening a number of suspected substandard oils were proved unqualified by determination of fatty acid composition and 11, 12, 13, 17 fatty acid content. Through the combination of several detection methods, the causes for disqualification of vegetable oils can be further inferred.

  15. New rapid DNA extraction method with Chelex from Venturia inaequalis spores.

    Science.gov (United States)

    Turan, Ceren; Nanni, Irene Maja; Brunelli, Agostino; Collina, Marina

    2015-08-01

    The objective of this study was to develop a rapid method to isolate DNA from Venturia inaequalis spores for use in diagnostic DNA mutation analysis. Chelex-100 resin was evaluated and compared with a well established DNA exctraction method, utilizing CTAB in order to have a robust comparison. In this research we demonstrated that Chelex-100 efficiently makes extraction of the DNA from V. inaequalis spores available for direct use in molecular analyses. Also, the quantity and quality of extracted DNA were shown to be adequate for PCR analysis. Comparatively, the quality of DNA samples isolated using Chelex method was better than those extracted using CTAB. In conclusion, the Chelex method is recommended for PCR experiments considering its simplicity and cost-effectiveness. Copyright © 2015. Published by Elsevier B.V.

  16. Rapid and sensitive liquid chromatography-mass spectrometry method for determination of ropinirole in human plasma.

    Science.gov (United States)

    Bhatt, Jignesh; Jangid, Arvind; Shetty, Raghavendra; Shah, Bhavin; Kambli, Sandeep; Subbaiah, Gunta; Singh, Sadhana

    2006-03-18

    A rapid and robust liquid chromatography-mass spectrometry (LC-MS/MS) method was developed for non-ergoline dopamine D(2)-receptor agonist, ropinirole in human plasma using Es-citalopram oxalate as an internal standard. The method involves solid phase extraction from plasma, reversed-phase simple isocratic chromatographic conditions and mass spectrometric detection that enables a detection limit at picogram levels. The proposed method was validated with linear range of 20-1,200 pg/ml. The extraction recoveries for ropinirole and internal standard were 90.45 and 65.42%, respectively. The R.S.D.% of intra-day and inter-day assay was lower than 15%. For its sensitivity and reliability, the proposed method is particularly suitable for pharmacokinetic studies.

  17. Optimized static and video EEG rapid serial visual presentation (RSVP) paradigm based on motion surprise computation

    Science.gov (United States)

    Khosla, Deepak; Huber, David J.; Bhattacharyya, Rajan

    2017-05-01

    In this paper, we describe an algorithm and system for optimizing search and detection performance for "items of interest" (IOI) in large-sized images and videos that employ the Rapid Serial Visual Presentation (RSVP) based EEG paradigm and surprise algorithms that incorporate motion processing to determine whether static or video RSVP is used. The system works by first computing a motion surprise map on image sub-regions (chips) of incoming sensor video data and then uses those surprise maps to label the chips as either "static" or "moving". This information tells the system whether to use a static or video RSVP presentation and decoding algorithm in order to optimize EEG based detection of IOI in each chip. Using this method, we are able to demonstrate classification of a series of image regions from video with an azimuth value of 1, indicating perfect classification, over a range of display frequencies and video speeds.

  18. Improved method for rapid and accurate isolation and identification of Streptococcus mutans and Streptococcus sobrinus from human plaque samples.

    Science.gov (United States)

    Villhauer, Alissa L; Lynch, David J; Drake, David R

    2017-08-01

    Mutans streptococci (MS), specifically Streptococcus mutans (SM) and Streptococcus sobrinus (SS), are bacterial species frequently targeted for investigation due to their role in the etiology of dental caries. Differentiation of S. mutans and S. sobrinus is an essential part of exploring the role of these organisms in disease progression and the impact of the presence of either/both on a subject's caries experience. Of vital importance to the study of these organisms is an identification protocol that allows us to distinguish between the two species in an easy, accurate, and timely manner. While conducting a 5-year birth cohort study in a Northern Plains American Indian tribe, the need for a more rapid procedure for isolating and identifying high volumes of MS was recognized. We report here on the development of an accurate and rapid method for MS identification. Accuracy, ease of use, and material and time requirements for morphological differentiation on selective agar, biochemical tests, and various combinations of PCR primers were compared. The final protocol included preliminary identification based on colony morphology followed by PCR confirmation of species identification using primers targeting regions of the glucosyltransferase (gtf) genes of SM and SS. This method of isolation and identification was found to be highly accurate, more rapid than the previous methodology used, and easily learned. It resulted in more efficient use of both time and material resources. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Simple and rapid methods for detecting Salmonella enteritidis in raw eggs.

    Science.gov (United States)

    Seo, Kun-Ho; Holt, Peter S; Stone, Henry D; Gast, Richard K

    2003-10-15

    The Centers for Disease Control and Prevention estimates there were 300,000 cases of Salmonella enteritidis (SE) in 1997. Egg products were associated with many of the cases. To address this problem, many producers implemented flock surveillance of the SE situation at their facilities. A rapid and simple method for detecting SE from poultry samples is critical for the effective implementation of such testing strategies. A lateral flow device for the detection of SE utilized in this study was manufactured by Neogen, Lansing, MI. The test panel is a presumptive qualitative test system that detects only members of Group D1 Salmonella species. A series of studies were conducted to optimize the test procedure for raw eggs with different sample preparations. A novel antigen extraction method was developed for use with the test panel kit. The detection limit of the test panel kit was increased approximately tenfold when the extraction method was used. Detection of SE was 100% in raw egg pools inoculated with 10 SE cells per ml of egg and incubated at a 1:10 ratio in buffered peptone water (BPW) or tetrathionate brilliant green broth (TBG) for 24 h at 37 degrees C. The developed lateral flow test kit could provide a simple, rapid, and inexpensive method for egg producers and processors to test specifically for Salmonella group D1 serovars, such as SE, in egg samples.

  20. Note: Non-invasive optical method for rapid determination of alignment degree of oriented nanofibrous layers

    Energy Technology Data Exchange (ETDEWEB)

    Pokorny, M.; Rebicek, J. [R& D Department, Contipro Biotech s.r.o., 561 02 Dolni Dobrouc (Czech Republic); Klemes, J. [R& D Department, Contipro Pharma a.s., 561 02 Dolni Dobrouc (Czech Republic); Kotzianova, A. [R& D Department, Contipro Pharma a.s., 561 02 Dolni Dobrouc (Czech Republic); Department of Chemistry, Faculty of Science, Masaryk University, Kamenice 5, CZ-62500 Brno (Czech Republic); Velebny, V. [R& D Department, Contipro Biotech s.r.o., 561 02 Dolni Dobrouc (Czech Republic); R& D Department, Contipro Pharma a.s., 561 02 Dolni Dobrouc (Czech Republic)

    2015-10-15

    This paper presents a rapid non-destructive method that provides information on the anisotropic internal structure of nanofibrous layers. A laser beam of a wavelength of 632.8 nm is directed at and passes through a nanofibrous layer prepared by electrostatic spinning. Information about the structural arrangement of nanofibers in the layer is directly visible in the form of a diffraction image formed on a projection screen or obtained from measured intensities of the laser beam passing through the sample which are determined by the dependency of the angle of the main direction of polarization of the laser beam on the axis of alignment of nanofibers in the sample. Both optical methods were verified on Polyvinyl alcohol (PVA) nanofibrous layers (fiber diameter of 470 nm) with random, single-axis aligned and crossed structures. The obtained results match the results of commonly used methods which apply the analysis of electron microscope images. The presented simple method not only allows samples to be analysed much more rapidly and without damaging them but it also makes possible the analysis of much larger areas, up to several square millimetres, at the same time.

  1. Rapid intrinsic fluorescence method for direct identification of pathogens in blood cultures.

    Science.gov (United States)

    Walsh, John D; Hyman, Jay M; Borzhemskaya, Larisa; Bowen, Ann; McKellar, Caroline; Ullery, Michael; Mathias, Erin; Ronsick, Christopher; Link, John; Wilson, Mark; Clay, Bradford; Robinson, Ron; Thorpe, Thurman; van Belkum, Alex; Dunne, W Michael

    2013-11-19

    A positive blood culture is a critical result that requires prompt identification of the causative agent. This article describes a simple method to identify microorganisms from positive blood culture broth within the time taken to perform a Gram stain (identification of the etiologic agent may benefit the clinical management of sepsis. Further evaluation is now warranted to determine the performance of the method using clinical blood culture specimens. Physicians often require the identity of the infective agent in order to make life-saving adjustments to empirical therapy or to switch to less expensive and/or more targeted antimicrobials. However, standard identification procedures take up to 2 days after a blood culture is signaled positive, and even most rapid molecular techniques take several hours to provide a result. Other techniques are faster (e.g., matrix-assisted laser desorption ionization-time of flight [MALDI-TOF] mass spectrometry) but require time-consuming manual processing steps and expensive equipment. There remains a clear need for a simple, inexpensive method to rapidly identify microorganisms directly from positive blood cultures. The promising new method described in this research article can identify microorganisms in minutes by optical spectroscopy, thus permitting the lab to simultaneously report the presence of a positive blood culture and the organism's identity.

  2. Use of refractometry and colorimetry as field methods to rapidly assess antimalarial drug quality.

    Science.gov (United States)

    Green, Michael D; Nettey, Henry; Villalva Rojas, Ofelia; Pamanivong, Chansapha; Khounsaknalath, Lamphet; Grande Ortiz, Miguel; Newton, Paul N; Fernández, Facundo M; Vongsack, Latsamy; Manolin, Ot

    2007-01-04

    The proliferation of counterfeit and poor-quality drugs is a major public health problem; especially in developing countries lacking adequate resources to effectively monitor their prevalence. Simple and affordable field methods provide a practical means of rapidly monitoring drug quality in circumstances where more advanced techniques are not available. Therefore, we have evaluated refractometry, colorimetry and a technique combining both processes as simple and accurate field assays to rapidly test the quality of the commonly available antimalarial drugs; artesunate, chloroquine, quinine, and sulfadoxine. Method bias, sensitivity, specificity and accuracy relative to high-performance liquid chromatographic (HPLC) analysis of drugs collected in the Lao PDR were assessed for each technique. The HPLC method for each drug was evaluated in terms of assay variability and accuracy. The accuracy of the combined method ranged from 0.96 to 1.00 for artesunate tablets, chloroquine injectables, quinine capsules, and sulfadoxine tablets while the accuracy was 0.78 for enterically coated chloroquine tablets. These techniques provide a generally accurate, yet simple and affordable means to assess drug quality in resource-poor settings.

  3. A two-step method for rapid characterization of electroosmotic flows in capillary electrophoresis.

    Science.gov (United States)

    Zhang, Wenjing; He, Muyi; Yuan, Tao; Xu, Wei

    2017-12-01

    The measurement of electroosmotic flow (EOF) is important in a capillary electrophoresis (CE) experiment in terms of performance optimization and stability improvement. Although several methods exist, there are demanding needs to accurately characterize ultra-low electroosmotic flow rates (EOF rates), such as in coated capillaries used in protein separations. In this work, a new method, called the two-step method, was developed to accurately and rapidly measure EOF rates in a capillary, especially for measuring the ultra-low EOF rates in coated capillaries. In this two-step method, the EOF rates were calculated by measuring the migration time difference of a neutral marker in two consecutive experiments, in which a pressure driven was introduced to accelerate the migration and the DC voltage was reversed to switch the EOF direction. Uncoated capillaries were first characterized by both this two-step method and a conventional method to confirm the validity of this new method. Then this new method was applied in the study of coated capillaries. Results show that this new method is not only fast in speed, but also better in accuracy. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Development of Novel Method for Rapid Extract of Radionuclides from Solution Using Polymer Ligand Film

    Science.gov (United States)

    Rim, Jung H.

    Accurate and fast determination of the activity of radionuclides in a sample is critical for nuclear forensics and emergency response. Radioanalytical techniques are well established for radionuclides measurement, however, they are slow and labor intensive, requiring extensive radiochemical separations and purification prior to analysis. With these limitations of current methods, there is great interest for a new technique to rapidly process samples. This dissertation describes a new analyte extraction medium called Polymer Ligand Film (PLF) developed to rapidly extract radionuclides. Polymer Ligand Film is a polymer medium with ligands incorporated in its matrix that selectively and rapidly extract analytes from a solution. The main focus of the new technique is to shorten and simplify the procedure necessary to chemically isolate radionuclides for determination by alpha spectrometry or beta counting. Five different ligands were tested for plutonium extraction: bis(2-ethylhexyl) methanediphosphonic acid (H2DEH[MDP]), di(2-ethyl hexyl) phosphoric acid (HDEHP), trialkyl methylammonium chloride (Aliquat-336), 4,4'(5')-di-t-butylcyclohexano 18-crown-6 (DtBuCH18C6), and 2-ethylhexyl 2-ethylhexylphosphonic acid (HEH[EHP]). The ligands that were effective for plutonium extraction further studied for uranium extraction. The plutonium recovery by PLFs has shown dependency on nitric acid concentration and ligand to total mass ratio. H2DEH[MDP] PLFs performed best with 1:10 and 1:20 ratio PLFs. 50.44% and 47.61% of plutonium were extracted on the surface of PLFs with 1M nitric acid for 1:10 and 1:20 PLF, respectively. HDEHP PLF provided the best combination of alpha spectroscopy resolution and plutonium recovery with 1:5 PLF when used with 0.1M nitric acid. The overall analyte recovery was lower than electrodeposited samples, which typically has recovery above 80%. However, PLF is designed to be a rapid field deployable screening technique and consistency is more important

  5. Rapid development of paper-based fluidic diagnostic devices

    CSIR Research Space (South Africa)

    Smith, S

    2014-11-01

    Full Text Available DEVELOPMENT OF PAPER-BASED FLUIDIC DIAGNOSTIC DEVICES S. Smith1*, H. Chen2, K. Moodley3, T. Joubert4 & K. Land5 1-5Department of Materials Science and Manufacturing Council for Scientific and Industrial Research, South Africa 1ssmith@csir.co.za,2jchen...

  6. A rapid and quantitative method to detect human circulating tumor cells in a preclinical animal model.

    Science.gov (United States)

    Tu, Shih-Hsin; Hsieh, Yi-Chen; Huang, Li-Chi; Lin, Chun-Yu; Hsu, Kai-Wen; Hsieh, Wen-Shyang; Chi, Wei-Ming; Lee, Chia-Hwa

    2017-06-23

    As cancer metastasis is the deadliest aspect of cancer, causing 90% of human deaths, evaluating the molecular mechanisms underlying this process is the major interest to those in the drug development field. Both therapeutic target identification and proof-of-concept experimentation in anti-cancer drug development require appropriate animal models, such as xenograft tumor transplantation in transgenic and knockout mice. In the progression of cancer metastasis, circulating tumor cells (CTCs) are the most critical factor in determining the prognosis of cancer patients. Several studies have demonstrated that measuring CTC-specific markers in a clinical setting (e.g., flow cytometry) can provide a current status of cancer development in patients. However, this useful technique has rarely been applied in the real-time monitoring of CTCs in preclinical animal models. In this study, we designed a rapid and reliable detection method by combining a bioluminescent in vivo imaging system (IVIS) and quantitative polymerase chain reaction (QPCR)-based analysis to measure CTCs in animal blood. Using the IVIS Spectrum CT System with 3D-imaging on orthotropic-developed breast-tumor-bearing mice. In this manuscript, we established a quick and reliable method for measuring CTCs in a preclinical animal mode. The key to this technique is the use of specific human and mouse GUS primers on DNA/RNA of mouse peripheral blood under an absolute qPCR system. First, the high sensitivity of cancer cell detection on IVIS was presented by measuring the luciferase carried MDA-MB-231 cells from 5 to 5x10(11) cell numbers with great correlation (R(2) = 0.999). Next, the MDA-MB-231 cell numbers injected by tail vein and their IVIS radiance signals were strongly corrected with qPCR-calculated copy numbers (R(2) > 0.99). Furthermore, by applying an orthotropic implantation animal model, we successfully distinguished xenograft tumor-bearing mice and control mice with a significant difference (p < 0

  7. A computer-based matrix for rapid calculation of pulmonary hemodynamic parameters in congenital heart disease.

    Science.gov (United States)

    Lopes, Antonio Augusto; Dos Anjos Miranda, Rogério; Gonçalves, Rilvani Cavalcante; Thomaz, Ana Maria

    2009-07-01

    In patients with congenital heart disease undergoing cardiac catheterization for hemodynamic purposes, parameter estimation by the indirect Fick method using a single predicted value of oxygen consumption has been a matter of criticism. We developed a computer-based routine for rapid estimation of replicate hemodynamic parameters using multiple predicted values of oxygen consumption. Using Microsoft® Excel facilities, we constructed a matrix containing 5 models (equations) for prediction of oxygen consumption, and all additional formulas needed to obtain replicate estimates of hemodynamic parameters. By entering data from 65 patients with ventricular septal defects, aged 1 month to 8 years, it was possible to obtain multiple predictions for oxygen consumption, with clear between-age groups (P <.001) and between-methods (P <.001) differences. Using these predictions in the individual patient, it was possible to obtain the upper and lower limits of a likely range for any given parameter, which made estimation more realistic. The organized matrix allows for rapid obtainment of replicate parameter estimates, without error due to exhaustive calculations.

  8. Rapid and accurate identification of microorganisms contaminating cosmetic products based on DNA sequence homology.

    Science.gov (United States)

    Fujita, Y; Shibayama, H; Suzuki, Y; Karita, S; Takamatsu, S

    2005-12-01

    The aim of this study was to develop rapid and accurate procedures to identify microorganisms contaminating cosmetic products, based on the identity of the nucleotide sequences of the internal transcribed spacer (ITS) region of the ribosomal RNA coding DNA (rDNA). Five types of microorganisms were isolated from the inner portion of lotion bottle caps, skin care lotions, and cleansing gels. The rDNA ITS region of microorganisms was amplified through the use of colony-direct PCR or ordinal PCR using DNA extracts as templates. The nucleotide sequences of the amplified DNA were determined and subjected to homology search of a publicly available DNA database. Thereby, we obtained DNA sequences possessing high similarity with the query sequences from the databases of all the five organisms analyzed. The traditional identification procedure requires expert skills, and a time period of approximately 1 month to identify the microorganisms. On the contrary, 3-7 days were sufficient to complete all the procedures employed in the current method, including isolation and cultivation of organisms, DNA sequencing, and the database homology search. Moreover, it was possible to develop the skills necessary to perform the molecular techniques required for the identification procedures within 1 week. Consequently, the current method is useful for rapid and accurate identification of microorganisms, contaminating cosmetics.

  9. The BUME method: a new rapid and simple chloroform-free method for total lipid extraction of animal tissue

    Science.gov (United States)

    Löfgren, Lars; Forsberg, Gun-Britt; Ståhlman, Marcus

    2016-06-01

    In this study we present a simple and rapid method for tissue lipid extraction. Snap-frozen tissue (15-150 mg) is collected in 2 ml homogenization tubes. 500 μl BUME mixture (butanol:methanol [3:1]) is added and automated homogenization of up to 24 frozen samples at a time in less than 60 seconds is performed, followed by a 5-minute single-phase extraction. After the addition of 500 μl heptane:ethyl acetate (3:1) and 500 μl 1% acetic acid a 5-minute two-phase extraction is performed. Lipids are recovered from the upper phase by automated liquid handling using a standard 96-tip robot. A second two-phase extraction is performed using 500 μl heptane:ethyl acetate (3:1). Validation of the method showed that the extraction recoveries for the investigated lipids, which included sterols, glycerolipids, glycerophospholipids and sphingolipids were similar or better than for the Folch method. We also applied the method for lipid extraction of liver and heart and compared the lipid species profiles with profiles generated after Folch and MTBE extraction. We conclude that the BUME method is superior to the Folch method in terms of simplicity, through-put, automation, solvent consumption, economy, health and environment yet delivering lipid recoveries fully comparable to or better than the Folch method.

  10. Rapid detection of carbapenemase production in Enterobacteriaceae using a modified paper strip Carba NP method.

    Science.gov (United States)

    Ho, Pak-Leung; Wang, Ya; Tse, Cindy Wing-Sze; Fung, Kitty Sau-Chun; Cheng, Vincent Ch-Chung; Lee, Rodney; To, Wing-Kin; Lai, Raymond Wai-Man; Luk, Wei-Kwang; Que, Tak-Lun; Tsang, Dominic Ngai-Chong

    2017-10-25

    Rapid and accurate detection of carbapenemase-producing Enterobacteriaceae (CPE) is important for preventing their spread in healthcare settings. We compared the performance of the Carba NP test using the CLSI tube method with that using a modified paper strip method for detection of carbapenemase in 390 Enterobacteriaceae isolates. The isolates were identified by Hong Kong's carbapenem-resistant Enterobacteriaceae surveillance program in 2016 and comprised 213 CPE and 177 carbapenemase-negative Enterobacteriaceae Molecular genotype was used as the reference. Test results were read at different time points for the CLSI method (1 min, 5 min, 1 h and 2 h) and strip method (1 min, 5 min). The strip CNP and CLSI CNP tests correctly detect carbapenemase production in 93% and 93% KPC producers, 100% and 38% IMI producers, 94% and 85% IMP producers, 98% and 90% NDM producers, and, 29% and 12% OXA producers, respectively. Overall, the strip method has superior sensitivity than the CLSI method (86% vs. 75%, respectively, P NP test using the modified strip method has a higher sensitivity and a shorter assay time than using the CLSI tube method. Copyright © 2017 American Society for Microbiology.

  11. rapid mini-prep DNA extraction method in rice (Oryza sativa ...

    African Journals Online (AJOL)

    method, optimized for rice, which was achieved via some modifications in present DNA extraction methods, especially in first step of cell wall lyses and the use of cheap and frequent chemicals found in every laboratory is presented. Normal quality and quantity was obtained by the method. The PCR based assays also ...

  12. [A rapid method for the quantitative determination of protein in urine].

    Science.gov (United States)

    Kariagina, I Iu; Slepysheva, V V; Kozlov, A V

    1996-01-01

    A simple, economic, and available method for measuring protein in the urine is proposed. It is based on the capacity of bromophenol blue stain to form a complex with proteins in acid medium, which is characterized by absorption maximum at a wave-length of 597 nm. The proposed method is compared with the sulfosalicylic acid test and the Biuret method.

  13. Rapid earthquake detection through GPU-Based template matching

    Science.gov (United States)

    Mu, Dawei; Lee, En-Jui; Chen, Po

    2017-12-01

    The template-matching algorithm (TMA) has been widely adopted for improving the reliability of earthquake detection. The TMA is based on calculating the normalized cross-correlation coefficient (NCC) between a collection of selected template waveforms and the continuous waveform recordings of seismic instruments. In realistic applications, the computational cost of the TMA is much higher than that of traditional techniques. In this study, we provide an analysis of the TMA and show how the GPU architecture provides an almost ideal environment for accelerating the TMA and NCC-based pattern recognition algorithms in general. So far, our best-performing GPU code has achieved a speedup factor of more than 800 with respect to a common sequential CPU code. We demonstrate the performance of our GPU code using seismic waveform recordings from the ML 6.6 Meinong earthquake sequence in Taiwan.

  14. Rapid Detection and Identification of Infectious Pathogens Based on High-throughput Sequencing

    Directory of Open Access Journals (Sweden)

    Pei-Xiang Ni

    2015-01-01

    Full Text Available Background: The dilemma of pathogens identification in patients with unidentified clinical symptoms such as fever of unknown origin exists, which not only poses a challenge to both the diagnostic and therapeutic process by itself, but also to expert physicians. Methods: In this report, we have attempted to increase the awareness of unidentified pathogens by developing a method to investigate hitherto unidentified infectious pathogens based on unbiased high-throughput sequencing. Results: Our observations show that this method supplements current diagnostic technology that predominantly relies on information derived five cases from the intensive care unit. This methodological approach detects viruses and corrects the incidence of false positive detection rates of pathogens in a much shorter period. Through our method is followed by polymerase chain reaction validation, we could identify infection with Epstein-Barr virus, and in another case, we could identify infection with Streptococcus viridians based on the culture, which was false positive. Conclusions: This technology is a promising approach to revolutionize rapid diagnosis of infectious pathogens and to guide therapy that might result in the improvement of personalized medicine.

  15. Vegan diet-based lifestyle program rapidly lowers homocysteine levels.

    Science.gov (United States)

    DeRose, D J; Charles-Marcel, Z L; Jamison, J M; Muscat, J E; Braman, M A; McLane, G D; Keith Mullen, J

    2000-03-01

    Plasma homocysteine levels have been directly associated with cardiac disease risk. Current research raises concerns as to whether comprehensive lifestyle approaches including a plant-based diet may interact with other known modulators of homocysteine levels. We report our observations of homocysteine levels in 40 self-selected subjects who participated in a vegan diet-based lifestyle program. Each subject attended a residential lifestyle change program at the Lifestyle Center of America in Sulphur, Oklahoma and had fasting plasma total homocysteine measured on enrollment and then after 1 week of lifestyle intervention. The intervention included a vegan diet, moderate physical exercise, stress management and spirituality enhancement sessions, group support, and exclusion of tobacco, alcohol, and caffeine. B vitamin supplements known to reduce blood homocysteine levels were not provided. Subjects' mean homocysteine levels fell 13%: from 8.66 micromol/L (SD 2.7 micromol/L) to 7.53 micromol/L (SD 2.12 micromol/L; P < 0.0001). Subgroup analysis showed that homocysteine decreased across a range of demographic and diagnostic categories. Conclusions. Our results suggest that broad-based lifestyle interventions favorably impact homocysteine levels. Furthermore, analysis of Lifestyle Center of America program components suggests that other factors in addition to B vitamin intake may be involved in the observed homocysteine lowering.

  16. Rapid Staining Method to Detect and Identify Downy Mildew (Peronospora belbahrii in Basil

    Directory of Open Access Journals (Sweden)

    Adolfina R. Koroch

    2013-07-01

    Full Text Available Premise of the study: Demand for fresh-market sweet basil continues to increase, but in 2009 a new pathogen emerged, threatening commercial field/greenhouse production and leading to high crop losses. This study describes a simple and effective staining method for rapid microscopic detection of basil downy mildew (Peronospora belbahrii from leaves of basil (Ocimum basilicum. Methods and Results: Fresh leaf sections infected with P. belbahrii were placed on a microscope slide, cleared with Visikol™, and stained with iodine solution followed by one drop of 70% sulfuric acid. Cell walls of the pathogen were stained with a distinct coloration, providing a high-contrast image between the pathogen and plant. Conclusions: This new staining method can be used successfully to identify downy mildew in basil, which then can significantly reduce its spread if identified early, coupled with mitigation strategies. This technique can facilitate the control of the disease, without expensive and specialized equipment.

  17. Large Rapidity Gap Method to Select Soft Diffraction Dissociation at the LHC

    Directory of Open Access Journals (Sweden)

    Emily Nurse

    2016-01-01

    Full Text Available In proton-proton (pp collisions, any process involves exchanging the vacuum quantum numbers is known as diffractive process. A diffractive process with no large Q2 is called soft diffractive process. The diffractive processes are important for understanding nonperturbative QCD effects and they also constitute a significant fraction of the total pp cross section. The diffractive events are typically characterized by a region of the detector without particles, known as a rapidity gap. In order to observe diffractive events in this way, we consider the pseudorapidity acceptance in the forward region of the ATLAS and CMS detectors at the Large Hadron Collider (LHC and discuss the methods to select soft diffractive dissociation for pp collisions at s=7 TeV. It is shown that, in the limited detector rapidity acceptance, it is possible to select diffractive dissociation events by requiring a rapidity gap in the event; however, without using forward detectors, it seems not possible to fully separate single and double diffractive dissociation events. The Zero Degree Calorimeters can be used to distinguish the type of the diffractive processes up to a certain extent.

  18. Hierarchically rough, mechanically durable and superhydrophobic epoxy coatings through rapid evaporation spray method

    Energy Technology Data Exchange (ETDEWEB)

    Simovich, Tomer; Wu, Alex H.; Lamb, Robert N., E-mail: rnlamb@unimelb.edu.au

    2015-08-31

    A mechanically durable and scalable superhydrophobic coating was fabricated by combining the advantages of both bottom-up and top-down approaches into a one-pot, one-step application method. This is achieved by spray coating a solution consisting of silica nanoparticles, which are embedded within epoxy resin, onto a heated substrate to rapidly drive both solvent evaporation and curing simultaneously. By maintaining a high substrate temperature, the arrival of spray-delivered micrometer-sized droplets are rapidly cured onto the substrate to form surface microroughness, while simultaneously, rapid solvent evaporation within each droplet results in the formation of a nanoporous structure. SEM, dual-beam FIB, and cross-sectional TEM/EDAX elemental mapping were used to confirm both the chemistry and the requisite micro- and nano-porosity within the coating structure requisite for superhydrophobicity. The resultant coatings exhibit contact angles greater than 150° (153.8° ± 0.8°) and roll-off angles of 8° ± 2°, with a coating hardness of 6H on the pencil hardness scale, and a rating of 5 on an ASTM crosshatch test. - Highlights: • A highly superhydrophobic coating was fabricated utilizing epoxy and nanoparticles. • The coating was demonstrated to be very durable and abrasion resistant. • The fabrication involves a novel, scalable one-pot synthesis technique.

  19. Rapid Method for Ra-226 and Ra-228 in Water Samples

    Energy Technology Data Exchange (ETDEWEB)

    Maxwell, Sherrod, L. III

    2006-02-10

    The measurement of radium isotopes in natural waters is important for oceanographic studies and for public health reasons. Ra-226 (1620 year half-life) is one of the most toxic of the long-lived alpha emitters present in the environment due to its long life and its tendency to concentrate in bones, which increases the internal radiation dose of individuals. The analysis of radium-226 and radium-228 in natural waters can be tedious and time-consuming. Different sample preparation methods are often required to prepare Ra-226 and Ra-228 for separate analyses. A rapid method has been developed at the Savannah River Environmental Laboratory that effectively separates both Ra-226 and Ra-228 (via Ac-228) for assay. This method uses MnO{sub 2} Resin from Eichrom Technologies (Darien, IL, USA) to preconcentrate Ra-226 and Ra-228 rapidly from water samples, along with Ba-133 tracer. DGA Resin{reg_sign} (Eichrom) and Ln-Resin{reg_sign} (Eichrom) are employed in tandem to prepare Ra-226 for assay by alpha spectrometry and to determine Ra-228 via the measurement of Ac-228 by gas proportional counting. After preconcentration, the manganese dioxide is dissolved from the resin and passed through stacked Ln-Resin-DGA Resin cartridges that remove uranium and thorium interferences and retain Ac-228 on DGA Resin. The eluate that passed through this column is evaporated, redissolved in a lower acidity and passed through Ln-Resin again to further remove interferences before performing a barium sulfate microprecipitation. The Ac-228 is stripped from the resin, collected using cerium fluoride microprecipitation and counted by gas proportional counting. By using vacuum box cartridge technology with rapid flow rates, sample preparation time is minimized.

  20. Rapid expansion method (REM) for time‐stepping in reverse time migration (RTM)

    KAUST Repository

    Pestana, Reynam C.

    2009-01-01

    We show that the wave equation solution using a conventional finite‐difference scheme, derived commonly by the Taylor series approach, can be derived directly from the rapid expansion method (REM). After some mathematical manipulation we consider an analytical approximation for the Bessel function where we assume that the time step is sufficiently small. From this derivation we find that if we consider only the first two Chebyshev polynomials terms in the rapid expansion method we can obtain the second order time finite‐difference scheme that is frequently used in more conventional finite‐difference implementations. We then show that if we use more terms from the REM we can obtain a more accurate time integration of the wave field. Consequently, we have demonstrated that the REM is more accurate than the usual finite‐difference schemes and it provides a wave equation solution which allows us to march in large time steps without numerical dispersion and is numerically stable. We illustrate the method with post and pre stack migration results.

  1. wzi Gene Sequencing, a Rapid Method for Determination of Capsular Type for Klebsiella Strains

    Science.gov (United States)

    Passet, Virginie; Haugaard, Anita Björk; Babosan, Anamaria; Kassis-Chikhani, Najiby; Struve, Carsten; Decré, Dominique

    2013-01-01

    Pathogens of the genus Klebsiella have been classified into distinct capsular (K) types for nearly a century. K typing of Klebsiella species still has important applications in epidemiology and clinical microbiology, but the serological method has strong practical limitations. Our objective was to evaluate the sequencing of wzi, a gene conserved in all capsular types of Klebsiella pneumoniae that codes for an outer membrane protein involved in capsule attachment to the cell surface, as a simple and rapid method for the prediction of K type. The sequencing of a 447-nucleotide region of wzi distinguished the K-type reference strains with only nine exceptions. A reference wzi sequence database was created by the inclusion of multiple strains representing K types associated with high virulence and multidrug resistance. A collection of 119 prospective clinical isolates of K. pneumoniae were then analyzed in parallel by wzi sequencing and classical K typing. Whereas K typing achieved typeability for 81% and discrimination for 94.4% of the isolates, these figures were 98.1% and 98.3%, respectively, for wzi sequencing. The prediction of K type once the wzi allele was known was 94%. wzi sequencing is a rapid and simple method for the determination of the K types of most K. pneumoniae clinical isolates. PMID:24088853

  2. A rapid method for measuring soil water content in the field with a areometer

    Directory of Open Access Journals (Sweden)

    Calbo Adonai Gimenez

    2002-01-01

    Full Text Available The availability of a rapid method to evaluate the soil water content (U can be an important tool to determine the moment to irrigate. The soil areometer consists of an elongated hydrostatic balance with a weighing pan, a graduated neck, a float and a pynometric flask. In this work an areometer was adapted to rapidly measure soil water content without the need of drying the soil. The expression U = (M A - M AD/(M M -M A was used to calculate the soil water content. In this equation M M is the mass to level the areometer with the pycnometric flask filled with water, M A the mass to level the areometer with a mass M M of soil in the pycnometer, the volume being completed with water, and similarly M AD the mass added to the pan to level the areometer with a mass M M of dried soil in the pycnometric flask. The convenience of this method is that the values M M and M AD are known. Consequently, the decision on irrigation can be made after a measurement that takes, about, ten minutes. The procedure involves only stirring the soil with water for at least 2 minutes to remove the adhered air. The soil water content data obtained with the areometric method were similar to those obtained weighing the soil before and after drying to constant weight, in an oven at 105º C.

  3. Single-step blood direct PCR: A robust and rapid method to diagnose triplet repeat disorders.

    Science.gov (United States)

    Singh, Inder; Swarup, Vishnu; Shakya, Sunil; Goyal, Vinay; Faruq, Mohammed; Srivastava, Achal Kumar

    2017-08-15

    DNA extraction prior to polymerase chain reaction (PCR) amplification in genetic diagnoses of triplet repeat disorders (TRDs) is tedious and labour-intensive and has the limitations of sample contamination with foreign DNA, including that from preceding samples. Therefore, we aimed to develop a rapid, robust, and cost-effective method for expeditious genetic investigation of TRDs from whole blood as a DNA template. Peripheral blood samples were collected from 70 clinically suspected patients of progressive ataxia. The conventional method using genomic DNA and single-step Blood-Direct PCR (BD-PCR) method with just 2μl of whole blood sample were tested to amplify triplet repeat expansion in genes related to spinocerebellar ataxia (SCA) types 1, 2, 3, 12 and Friedreich's ataxia (FRDA). Post-PCR, the allele sizes were mapped and repeat numbers were calculated using GeneMapper and macros run in Microsoft Excel programmes. Successful amplification of target regions was achieved in all samples by both methods. The frequency of the normal and mutated allele was concordant between both methods, diagnosing 37% positive for a mutation in either of the candidate genes. The BD-PCR resulted in higher intensities of product peaks of normal and pathogenic alleles. The nearly-accurate sizing of the normal and expanded allele was achieved in a shorter time (4-5h), without DNA extraction and any risk of cross contamination, which suggests the BD-PCR to be a reliable, inexpensive, and rapid method to confirm TRDs. This technique can be introduced in routine diagnostic procedures of other tandem repeat disorders. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. A Rapid Python-Based Methodology for Target-Focused Combinatorial Library Design.

    Science.gov (United States)

    Li, Shiliang; Song, Yuwei; Liu, Xiaofeng; Li, Honglin

    2016-01-01

    The chemical space is so vast that only a small portion of it has been examined. As a complementary approach to systematically probe the chemical space, virtual combinatorial library design has extended enormous impacts on generating novel and diverse structures for drug discovery. Despite the favorable contributions, high attrition rates in drug development that mainly resulted from lack of efficacy and side effects make it increasingly challenging to discover good chemical starting points. In most cases, focused libraries, which are restricted to particular regions of the chemical space, are deftly exploited to maximize hit rate and improve efficiency at the beginning of the drug discovery and drug development pipeline. This paper presented a valid methodology for fast target-focused combinatorial library design in both reaction-based and production-based ways with the library creating rates of approximately 70,000 molecules per second. Simple, quick and convenient operating procedures are the specific features of the method. SHAFTS, a hybrid 3D similarity calculation software, was embedded to help refine the size of the libraries and improve hit rates. Two target-focused (p38-focused and COX2-focused) libraries were constructed efficiently in this study. This rapid library enumeration method is portable and applicable to any other targets for good chemical starting points identification collaborated with either structure-based or ligand-based virtual screening.

  5. Rapid Texture Optimization of Three-Dimensional Urban Model Based on Oblique Images.

    Science.gov (United States)

    Zhang, Weilong; Li, Ming; Guo, Bingxuan; Li, Deren; Guo, Ge

    2017-04-20

    Seamless texture mapping is one of the key technologies for photorealistic 3D texture reconstruction. In this paper, a method of rapid texture optimization of 3D urban reconstruction based on oblique images is proposed aiming at the existence of texture fragments, seams, and inconsistency of color in urban 3D texture mapping based on low-altitude oblique images. First, we explore implementing radiation correction on the experimental images with a radiation procession algorithm. Then, an efficient occlusion detection algorithm based on OpenGL is proposed according to the mapping relation between the terrain triangular mesh surface and the images to implement the occlusion detection of the visible texture on the triangular facets as well as create a list of visible images. Finally, a texture clustering algorithm is put forward based on Markov Random Field utilizing the inherent attributes of the images and solve the energy function minimization by Graph-Cuts. The experimental results display that the method is capable of decreasing the existence of texture fragments, seams, and inconsistency of color in the 3D texture model reconstruction.

  6. Rapid Assemblers for Voxel-Based VLSI Robotics

    Science.gov (United States)

    2014-02-12

    and actuators based on small DC motors. We call these parts Bitblox, and intend to use them as the " ink " in a system that automatically designs and...0 ∗ ≅ −0.010 ∗ 2 − 0.1|0 ∗| + 2) [6]. The permeability (which is assumed to be isotropic) can be estimated analytically for a bed of packed...spheres by relating it to the permeability of a series of parallel straight cylinders [7]. Since permeability of spherical packed bed of spheres can

  7. A Rapid Method for Determining the Concentration of Recombinant Protein Secreted from Pichia pastoris

    Science.gov (United States)

    Sun, L. W.; Zhao, Y.; Niu, L. P.; Jiang, R.; Song, Y.; Feng, H.; feng, K.; Qi, C.

    2011-02-01

    Pichia secretive expression system is one of powerful eukaryotic expression systems in genetic engineering, which is especially suitable for industrial utilization. Because of the low concentration of the target protein in initial experiment, the methods and conditions for expression of the target protein should be optimized according to the protein yield repetitively. It is necessary to set up a rapid, simple and convenient analysis method for protein expression levels instead of the generally used method such as ultrafiltration, purification, dialysis, lyophilization and so on. In this paper, acetone precipitation method was chosen to concentrate the recombinant protein firstly after comparing with four different protein precipitation methods systematically, and then the protein was analyzed by SDS-Polyacrylamide Gel Electrophoresis. The recombinant protein was determined with the feature of protein band by the Automated Image Capture and 1-D Analysis Software directly. With this method, the optimized expression conditions of basic fibroblast growth factor secreted from pichia were obtained, which is as the same as using traditional methods. Hence, a convenient tool to determine the optimized conditions for the expression of recombinant proteins in Pichia was established.

  8. Comparison of the Immunomagnetic Separation/Adenosine Triphosphate Rapid Method and the Modified mTEC Membrane-Filtration Method for Enumeration of Escherichia coli

    Science.gov (United States)

    Brady, Amie M.G.; Bushon, Rebecca N.; Bertke, Erin E.

    2009-01-01

    Water quality at beaches is monitored for fecal indicator bacteria by traditional, culture-based methods that can take 18 to 24 hours to obtain results. A rapid detection method that provides estimated concentrations of fecal indicator bacteria within 1 hour from the start of sample processing would allow beach managers to post advisories or close the beach when the conditions are actually considered unsafe instead of a day later, when conditions may have changed. A rapid method that couples immunomagnetic separation with adenosine triphosphate detection (IMS/ATP rapid method) was evaluated through monitoring of Escherichia coli (E. coli) at three Lake Erie beaches in Ohio (Edgewater and Villa Angela in Cleveland and Huntington in Bay Village). Beach water samples were collected between 4 and 5 days per week during the recreational seasons (May through September) of 2006 and 2007. Composite samples were created in the lab from two point samples collected at each beach and were shown to be comparable substitutes for analysis of two individual samples. E. coli concentrations in composite samples, as determined by the culture-based method, ranged from 4 to 24,000 colony-forming units per 100 milliliters during this study across all beaches. Turbidity also was measured for each sample and ranged from 0.8 to 260 neophelometric turbidity ratio units. Environmental variables were noted at the time of sampling, including number of birds at the beach and wave height. Rainfall amounts were measured at National Weather Service stations at local airports. Turbidity, rainfall, and wave height were significantly related to the culture-based method results each year and for both years combined at each beach. The number of birds at the beach was significantly related to the culture-based method results only at Edgewater during 2006 and during both years combined. Results of the IMS/ATP method were compared to results of the culture-based method for samples by year for each beach

  9. PCR-based rapid genotyping of Stenotrophomonas maltophilia isolates

    Directory of Open Access Journals (Sweden)

    Zarrilli Raffaele

    2008-11-01

    Full Text Available Abstract Background All bacterial genomes contain repetitive sequences which are members of specific DNA families. Such repeats may occur as single units, or found clustered in multiple copies in a head-to-tail configuration at specific loci. The number of clustered units per locus is a strain-defining parameter. Assessing the length variability of clusters of repeats is a versatile typing methodology known as multilocus variable number of tandem repeat analysis (MLVA. Results Stenotrophomonas maltophilia is an environmental bacterium increasingly involved in nosocomial infections and resistant to most antibiotics. The availability of the whole DNA sequence of the S. maltophilia strain K279a allowed us to set up fast and accurate PCR-based diagnostic protocols based on the measurement of length variations of loci carrying a variable number of short palindromic repeats marking the S. maltophilia genome. On the basis of the amplimers size, it was possible to deduce the number of repeats present at 12 different loci in a collection of S. maltophilia isolates, and therefore label each of them with a digit. PCR-negative regions were labelled 0. Co-amplification of two pairs of loci provided a 4-digit code sufficient for immediate subtyping. By increasing the number of loci analyzed, it should be possible to assign a more specific digit profile to isolates. In general, MLVA data match genotyping data obtained by PFGE (pulsed-field gel electrophoresis. However, some isolates exhibiting the same PCR profiles at all loci display distinct PFGE patterns. Conclusion The utilization of the present protocol allows to type several S. maltophilia isolates in hours. The results are immediately interpretable without the need for sophisticated softwares. The data can be easily reproducible, and compared among different laboratories.

  10. Rapid Reticulin Fiber Staining Method is Helpful for the Diagnosis of Pituitary Adenoma in Frozen Section.

    Science.gov (United States)

    Noh, Songmi; Kim, Sun Ho; Cho, Nam Hoon; Kim, Se Hoon

    2015-05-01

    Approximately 90% of neoplasms found in the sellar region are adenoma of the pituitary gland. The use of frozen sections for the diagnosis of pituitary adenomas has an accuracy of 90% and is useful in evaluating complete tumor removal. However, it is sometimes difficult to diagnose pituitary adenomas using frozen sections because of the small sample size and marked artifact, and the contiguity of the pituitary adenoma with normal pituitary gland tissue. In this study, we evaluated the use of our modified reticulin stain to make correct decision in frozen section with reduced stain time and investigated the objective diagnostic criteria of pituitary adenoma with reticulin stain. We used Gomori's silver impregnation methods to stain reticulin fibers in frozen pituitary gland sections of 36 samples from 24 patients. We modified the conventional staining method by reducing the overall staining time. We diagnosed pituitary lesion according to our interpretation criteria and compared the results to those of the conventional method and findings of hematoxylin and eosin-stained slides. Reticulin fiber staining of normal adenohypophysis outlines the supporting stroma around the blood vessels and shows regular of the gland meshwork interconnecting the capillaries. In contrast, reticulin fiber staining of the adenomatous tissue shows loss of meshwork or frequent fragmentation. Our modified reticulin stain is more rapid than the established method and shows similar levels of accuracy. Independent evaluation by two pathologists showed discrepancies in diagnosis in four out of 36 cases with modified reticulin stain. Our rapid modified reticulin staining method for frozen sections may be useful as a diagnostic tool for pituitary adenomas and can complement routine hematoxylin and eosin staining.

  11. Clinical usefulness of multiplex PCR lateral flow in MRSA detection: a novel, rapid genetic testing method.

    Science.gov (United States)

    Nihonyanagi, Shin; Kanoh, Yuhsaku; Okada, Kiyomi; Uozumi, Toshiki; Kazuyama, Yukumasa; Yamaguchi, Tokiko; Nakazaki, Nobuhiko; Sakurai, Keizou; Hirata, Yasuyoshi; Munekata, Shinichi; Ohtani, Shinichi; Takemoto, Tsuyoshi; Bandoh, Yuki; Akahoshi, Tohru

    2012-06-01

    Methicillin-resistant Staphylococcus aureus (MRSA) with exogenous cassette DNA containing the methicillin-resistant gene mecA (SCCmec) poses a problem as a drug-resistant bacterium responsible for hospital- and community-acquired infections. The frequency of MRSA detection has recently been increasing rapidly in Japan, and SCCmec has also been classified more diversely into types I-V. A rapid test is essential for early diagnosis and treatment of MRSA infections, but detection by conventional methods requires at least two days. The newly developed multiplex PCR lateral flow method allows specific amplification of femA to detect S. aureus, mecA to detect SCCmec, and kdpC to detect SCCmec type II; moreover, PCR products can be evaluated visually in about 3 h. In the present study, we developed a PCR lateral flow method for MRSA using this method and investigated its clinical usefulness in the detection of MRSA. The results showed a diagnostic concordance rate of 91.7% for MRSA and methicillin-susceptible S. aureus between bacteriological examination and PCR lateral flow, and a high level of specificity in PCR lateral flow. In addition, a higher detection rate for S. aureus using the same sample was observed for PCR lateral flow (70.2%) than for bacteriological tests (48.6%). The above results show that PCR lateral flow for MRSA detection has high sensitivity, specificity, and speed, and its clinical application as a method for early diagnosis of MRSA infections appears to be feasible.

  12. Optimal estimation and scheduling in aquifer management using the rapid feedback control method

    Science.gov (United States)

    Ghorbanidehno, Hojat; Kokkinaki, Amalia; Kitanidis, Peter K.; Darve, Eric

    2017-12-01

    Management of water resources systems often involves a large number of parameters, as in the case of large, spatially heterogeneous aquifers, and a large number of "noisy" observations, as in the case of pressure observation in wells. Optimizing the operation of such systems requires both searching among many possible solutions and utilizing new information as it becomes available. However, the computational cost of this task increases rapidly with the size of the problem to the extent that textbook optimization methods are practically impossible to apply. In this paper, we present a new computationally efficient technique as a practical alternative for optimally operating large-scale dynamical systems. The proposed method, which we term Rapid Feedback Controller (RFC), provides a practical approach for combined monitoring, parameter estimation, uncertainty quantification, and optimal control for linear and nonlinear systems with a quadratic cost function. For illustration, we consider the case of a weakly nonlinear uncertain dynamical system with a quadratic objective function, specifically a two-dimensional heterogeneous aquifer management problem. To validate our method, we compare our results with the linear quadratic Gaussian (LQG) method, which is the basic approach for feedback control. We show that the computational cost of the RFC scales only linearly with the number of unknowns, a great improvement compared to the basic LQG control with a computational cost that scales quadratically. We demonstrate that the RFC method can obtain the optimal control values at a greatly reduced computational cost compared to the conventional LQG algorithm with small and controllable losses in the accuracy of the state and parameter estimation.

  13. Efficient 3D frequency response modeling with spectral accuracy by the rapid expansion method

    KAUST Repository

    Chu, Chunlei

    2012-07-01

    Frequency responses of seismic wave propagation can be obtained either by directly solving the frequency domain wave equations or by transforming the time domain wavefields using the Fourier transform. The former approach requires solving systems of linear equations, which becomes progressively difficult to tackle for larger scale models and for higher frequency components. On the contrary, the latter approach can be efficiently implemented using explicit time integration methods in conjunction with running summations as the computation progresses. Commonly used explicit time integration methods correspond to the truncated Taylor series approximations that can cause significant errors for large time steps. The rapid expansion method (REM) uses the Chebyshev expansion and offers an optimal solution to the second-order-in-time wave equations. When applying the Fourier transform to the time domain wavefield solution computed by the REM, we can derive a frequency response modeling formula that has the same form as the original time domain REM equation but with different summation coefficients. In particular, the summation coefficients for the frequency response modeling formula corresponds to the Fourier transform of those for the time domain modeling equation. As a result, we can directly compute frequency responses from the Chebyshev expansion polynomials rather than the time domain wavefield snapshots as do other time domain frequency response modeling methods. When combined with the pseudospectral method in space, this new frequency response modeling method can produce spectrally accurate results with high efficiency. © 2012 Society of Exploration Geophysicists.

  14. A microcontroller platform for the rapid prototyping of functional electrical stimulation-based gait neuroprostheses.

    Science.gov (United States)

    Luzio de Melo, Paulo; da Silva, Miguel Tavares; Martins, Jorge; Newman, Dava

    2015-05-01

    Functional electrical stimulation (FES) has been used over the last decades as a method to rehabilitate lost motor functions of individuals with spinal cord injury, multiple sclerosis, and post-stroke hemiparesis. Within this field, researchers in need of developing FES-based control solutions for specific disabilities often have to choose between either the acquisition and integration of high-performance industry-level systems, which are rather expensive and hardly portable, or develop custom-made portable solutions, which despite their lower cost, usually require expert-level electronic skills. Here, a flexible low-cost microcontroller-based platform for rapid prototyping of FES neuroprostheses is presented, designed for reduced execution complexity, development time, and production cost. For this reason, the Arduino open-source microcontroller platform was used, together with off-the-shelf components whenever possible. The developed system enables the rapid deployment of portable FES-based gait neuroprostheses, being flexible enough to allow simple open-loop strategies but also more complex closed-loop solutions. The system is based on a modular architecture that allows the development of optimized solutions depending on the desired FES applications, even though the design and testing of the platform were focused toward drop foot correction. The flexibility of the system was demonstrated using two algorithms targeting drop foot condition within different experimental setups. Successful bench testing of the device in healthy subjects demonstrated these neuroprosthesis platform capabilities to correct drop foot. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  15. A rapid, highly accurate method for quantifying CALR mutant allele burden in persons with myeloproliferative neoplasms.

    Science.gov (United States)

    Yao, Qiu-Mei; Zhou, Jiao; Gale, Robert Peter; Li, Jin-Lan; Li, Ling-Di; Li, Ning; Chen, Shan-Shan; Ruan, Guo-Rui

    2015-10-01

    Calreticulin (CALR) mutations were recently identified in a substantial proportion of persons with essential thrombocythemia (ET) and with primary myelofibrosis (PMF) without JAK2(V617F). Consequently rapid, sensitive, and specific methods to detect and quantify these mutations are needed. We studied samples from 1088 persons with myeloproliferative neoplasms (MPNs) including 421 JAK2(V617F) negative subjects with ET, PMF, polycythemia vera (PV), chronic myeloid leukemia (CML) and hyper-eosinophilic syndrome (HES). Detection of CALR exon 9 mutations was done by PCR amplification followed by fragment length analysis and direct sequencing. Dilution assays were used to determine CALR mutant allele burden. We detected CALR mutations in blood and bone marrow samples from 152 subjects with ET and with PMF but not in samples from normal or persons with PV, CML, or HES. CALR mutant peaks were distinct from wild-type peaks and dilution experiments indicated a sensitivity level of 0.5-5% for a CALR mutant allele in a wild-type background. Diverse types of mutations were detected including deletions, insertions, and complex indels. All mutations were confirmed by direct sequencing. We also used dilution experiments to quantify mutant allele burden. We were able to reproducibly detect mutant allele levels as low 5% (0.5-5%) in a wild-type background. PCR amplification followed by fragment length analysis is a rapid, sensitive, and specific method for screening persons with MPNs for CALR mutations, especially those with ET and PMF and for estimating mutant allele burden.

  16. Rapid fabrication method of a microneedle mold with controllable needle height and width.

    Science.gov (United States)

    Lin, Yen-Heng; Lee, I-Chi; Hsu, Wei-Chieh; Hsu, Ching-Hong; Chang, Kai-Ping; Gao, Shao-Syuan

    2016-10-01

    The main issue of transdermal drug delivery is that macromolecular drugs cannot diffuse through the stratum corneum of skin. Many studies have pursued micro-sized needles encapsulated with drugs to overcome this problem, as these needles can pierce the stratum corneum and allow drugs to enter the circulatory system of the human body. However, most microneedle fabrication processes are time-consuming and require expensive equipment. In this study, we demonstrate a rapid method for fabricating a microneedle mold using drawing lithography and a UV-cured resin. The mold was filled with a water-soluble material, polyvinylpyrrolidone (PVP), which was then demolded to produce a water-soluble microneedle array. The results of an in vitro skin insertion test using PVP microneedles and pig ear skin demonstrated the feasibility of the microneedle mold. In addition, by controlling the viscosity of the UV-cured resin through various heat treatments, microneedles with different heights and aspect ratios were produced. Compared with other methods, this technology significantly simplifies and accelerates the mold fabrication process. In addition, the required equipment is relatively simple and inexpensive. Through this technology, we can rapidly fabricate microneedle molds with controllable dimensions for various applications.

  17. Passive acoustic methods for fine-scale tracking of harbour porpoises in tidal rapids.

    Science.gov (United States)

    Macaulay, Jamie; Gordon, Jonathan; Gillespie, Douglas; Malinka, Chloë; Northridge, Simon

    2017-02-01

    The growing interest in generating electrical power from tidal currents using tidal turbine generators raises a number of environmental concerns, including the risk that marine mammals might be injured or killed through collision with rotating turbine blades. To understand this risk, information on how marine mammals use tidal rapid habitats and in particular, their underwater movements and dive behaviour is required. Porpoises, which are the most abundant small cetacean at most European tidal sites, are difficult animals to tag, and the limited size of tidal habitats means that any telemetered animal would be likely to spend only a small proportion of time within them. Here, an alternative approach is explored, whereby passive acoustic monitoring (PAM) is used to obtain fine scale geo-referenced tracks of harbour porpoises in tidal rapid areas. Large aperture hydrophone arrays are required to obtain accurate locations of animals from PAM data and automated algorithms are necessary to process the large quantities of acoustic data collected on such systems during a typical survey. Methods to automate localisation, including a method to match porpoise detections on different hydrophones and separate different vocalising animals, and an assessment of the localisation accuracy of the large aperture hydrophone array are presented.

  18. Hyperspectral Imaging as a Rapid Quality Control Method for Herbal Tea Blends

    Directory of Open Access Journals (Sweden)

    Majolie Djokam

    2017-03-01

    Full Text Available In South Africa, indigenous herbal teas are enjoyed due to their distinct taste and aroma. The acclaimed health benefits of herbal teas include the management of chronic diseases such as hypertension and diabetes. Quality control of herbal teas has become important due to the availability of different brands of varying quality and the production of tea blends. The potential of hyperspectral imaging as a rapid quality control method for herbal tea blends from rooibos (Aspalathus linearis, honeybush (Cyclopia intermedia, buchu (Agathosma Betulina and cancerbush (Sutherlandia frutescens was investigated. Hyperspectral images of raw materials and intact tea bags were acquired using a sisuChema shortwave infrared (SWIR hyperspectral pushbroom imaging system (920–2514 nm. Principal component analysis (PCA plots showed clear discrimination between raw materials. Partial least squares discriminant analysis (PLS-DA models correctly predicted the raw material constituents of each blend and accurately determined the relative proportions. The results were corroborated independently using ultra-high performance liquid chromatography coupled to mass spectrometry (UHPLC-MS. This study demonstrated the application of hyperspectral imaging coupled with chemometric modelling as a reliable, rapid and non-destructive quality control method for authenticating herbal tea blends and to determine relative proportions in a tea bag.

  19. Simulation of Microstructure during Laser Rapid Forming Solidification Based on Cellular Automaton

    Directory of Open Access Journals (Sweden)

    Zhi-jian Wang

    2014-01-01

    Full Text Available The grain microstructure of molten pool during the solidification of TC4 titanium alloy in the single point laser cladding was investigated based on the CAFE model which is the cellular automaton (CA coupled with the finite element (FE method. The correct temperature field is the prerequisite for simulating the grain microstructure during the solidification of the molten pool. The model solves the energy equation by the FE method to simulate the temperature distribution in the molten pool of the single point laser cladding. Based on the temperature field, the solidification microstructure of the molten pool is also simulated with the CAFE method. The results show that the maximum temperature in the molten pool increases with the laser power and the scanning rate. The laser power has a larger influence on the temperature distribution of the molten pool than the scanning rate. During the solidification of the molten pool, the heat at the bottom of the molten pool transfers faster than that at the top of the molten pool. The grains rapidly grow into the molten pool, and then the columnar crystals are formed. This study has a very important significance for improving the quality of the structure parts manufactured through the laser cladding forming.

  20. Photograph-based ergonomic evaluations using the Rapid Office Strain Assessment (ROSA).

    Science.gov (United States)

    Liebregts, J; Sonne, M; Potvin, J R

    2016-01-01

    The Rapid Office Strain Assessment (ROSA) was developed to assess musculoskeletal disorder (MSD) risk factors for computer workstations. This study examined the validity and reliability of remotely conducted, photo-based assessments using ROSA. Twenty-three office workstations were assessed on-site by an ergonomist, and 5 photos were obtained. Photo-based assessments were conducted by three ergonomists. The sensitivity and specificity of the photo-based assessors' ability to correctly classify workstations was 79% and 55%, respectively. The moderate specificity associated with false positive errors committed by the assessors could lead to unnecessary costs to the employer. Error between on-site and photo-based final scores was a considerable ∼2 points on the 10-point ROSA scale (RMSE = 2.3), with a moderate relationship (ρ = 0.33). Interrater reliability ranged from fairly good to excellent (ICC = 0.667-0.856) and was comparable to previous results. Sources of error include the parallax effect, poor estimations of small joint (e.g. hand/wrist) angles, and boundary errors in postural binning. While this method demonstrated potential validity, further improvements should be made with respect to photo-collection and other protocols for remotely-based ROSA assessments. Copyright © 2015 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  1. Development of an isothermal amplification-based assay for the rapid visual detection of Salmonella bacteria.

    Science.gov (United States)

    Liu, Hai-Bin; Zang, Yu-Xuan; Du, Xin-Jun; Li, Ping; Wang, Shuo

    2017-09-01

    The efficient and timely detection of pathogens is a major concern worldwide. The aim of this study was to establish a rapid detection method for Salmonella bacteria in food samples to facilitate timely treatment. Widely used detection methods currently include culture-based methods and PCR-based methods. The former are time consuming, requiring 2 to 3 d, whereas the latter have higher accuracy but are typically complicated, requiring expertise and expensive instruments. In this study, a sensitive and rapid approach for the visual and point-of-use detection of Salmonella bacteria based on recombinase polymerase amplification (RPA) and a lateral-flow (LF) nucleic acid strip was established. We designed a pair of primers according to the invA gene of Salmonella bacteria: one was modified with digoxin, and the other was modified with biotin. In the presence of the biotin- and digoxin-modified primers and target DNA, the RPA produced a substantial amount of duplex DNA attached to biotin and digoxin. The products were detected using LF strips through immunoreaction: anti-digoxin antibodies on the gold nanoparticles, digoxin on the duplex, streptavidin on the LF test line, and biotin on the duplex. The developed RPA-LF assay allowed detection of Salmonella genomic DNA in less than 20 min with simple water bath equipment or portable thermal equipment. In addition, the RPA-LF assay was highly sensitive, with a detection limit as low as 20 fg of target DNA or 1.05 × 101 cfu of bacteria in pure culture, and highly specific, exhibiting no cross-reaction with Staphylococcus aureus, Escherichia coli, Listeria monocytogenes, Shigella, Enterobacter aerogenes, or Campylobacter jejuni. Importantly, Salmonella could be detected in milk and chicken breast at concentrations as low as 1.05 × 100 cfu/mL or 1.05 × 100 cfu/g after enrichment for 2 h and in eggs at 1.05 × 100 cfu/g after enrichment for 4 h. Furthermore, RPA was more sensitive than PCR, which requires a thermal cycling

  2. Rapid HPLC method for the simultaneous monitoring of duloxetine, venlaflaxine, fluoxetine and paroxetine in biofluids.

    Science.gov (United States)

    Samanidou, Victoria F; Kourti, Paraskevi V

    2009-08-01

    A simple and rapid HPLC method is developed for the determination of two serotonin-norepinephrine-reuptake inhibitors (duloxetine and venlaflaxine) and two selective serotonin-reuptake inhibitors (fluoxetine and paroxetine) in human biofluids. Separation was performed on an Inertsil ODS-3 column (250 x 4.0 mm, 5 µm) with acetonitrile-ammonium acetate (0.05 M, 41:59 v/v) at 235 nm, within 7 min. SPE on Oasis(®) HLB cartridges was applied for the isolation of analytes from biofluids. The developed methodology was validated in terms of sensitivity, linearity, accuracy, precision, stability and selectivity. Relative standard deviation was less than 10.4%. Limit of detection was 0.2-0.6 ng/µl in blood plasma and 0.1-0.8 ng/µl in urine. The method was successfully applied to biofluids from a patient under duloxetine treatment.

  3. A rapid and scalable method for selecting recombinant mouse monoclonal antibodies

    Directory of Open Access Journals (Sweden)

    Wright Gavin J

    2010-06-01

    Full Text Available Abstract Background Monoclonal antibodies with high affinity and selectivity that work on wholemount fixed tissues are valuable reagents to the cell and developmental biologist, and yet isolating them remains a long and unpredictable process. Here we report a rapid and scalable method to select and express recombinant mouse monoclonal antibodies that are essentially equivalent to those secreted by parental IgG-isotype hybridomas. Results Increased throughput was achieved by immunizing mice with pools of antigens and cloning - from small numbers of hybridoma cells - the functionally rearranged light and heavy chains into a single expression plasmid. By immunizing with the ectodomains of zebrafish cell surface receptor proteins expressed in mammalian cells and screening for formalin-resistant epitopes, we selected antibodies that gave expected staining patterns on wholemount fixed zebrafish embryos. Conclusions This method can be used to quickly select several high quality monoclonal antibodies from a single immunized mouse and facilitates their distribution using plasmids.

  4. A method for rapidly screening functionality of actin mutants and tagged actins

    Directory of Open Access Journals (Sweden)

    Rommelaere Heidi

    2004-01-01

    Full Text Available Recombinant production and biochemical analysis of actin mutants has been hampered by the fact that actin has an absolute requirement for the eukaryotic chaperone CCT to reach its native state. We therefore have developed a method to rapidly screen the folding capacity and functionality of actin variants, by combining in vitro expression of labelled actin with analysis on native gels, band shift assays or copolymerization tests. Additionally, we monitor, using immuno-fluorescence, incorporation of actin variants in cytoskeletal structures in transfected cells. We illustrate the method by two examples. In one we show that tagged versions of actin do not always behave native-like and in the other we study some of the molecular defects of three &bgr;-actin mutants that have been associated with diseases.

  5. A rapid and efficient DNA extraction method suitable for marine macroalgae.

    Science.gov (United States)

    Ramakrishnan, Gautham Subramaniam; Fathima, Anwar Aliya; Ramya, Mohandass

    2017-12-01

    Macroalgae are a diverse group of organisms. Marine macroalgae, in particular, have numerous medicinal and industrial applications. Molecular studies of macroalgae require suitable concentrations of DNA free of contaminants. At present, numerous protocols exist for DNA extraction from macroalgae. However, they are either time consuming, expensive or work only with few species. The method described in this study is rapid and efficient and applicable to different types of marine macroalgae. This method yields an average of 3.85 µg of DNA per 50 mg of algal tissue, with an average purity of 1.88. The isolated DNA was suitable for PCR amplification of universal plastid region of macroalgae.

  6. A Rapid Colorimetric Method Reveals Fraudulent Substitutions in Sea Urchin Roe Marketed in Sardinia (Italy).

    Science.gov (United States)

    Meloni, Domenico; Spina, Antonio; Satta, Gianluca; Chessa, Vittorio

    2016-06-25

    In recent years, besides the consumption of fresh sea urchin specimens, the demand of minimally-processed roe has grown considerably. This product has made frequent consumption in restaurants possible and frauds are becoming widespread with the partial replacement of sea urchin roe with surrogates that are similar in colour. One of the main factors that determines the quality of the roe is its colour and small differences in colour scale cannot be easily discerned by the consumers. In this study we have applied a rapid colorimetric method for reveal the fraudulent partial substitution of semi-solid sea urchin roe with liquid egg yolk. Objective assessment of whiteness (L*), redness (a*), yellowness (b*), hue (h*), and chroma (C*) was carried out with a digital spectrophotometer using the CIE L*a*b* colour measurement system. The colorimetric method highlighted statistically significant differences among sea urchin roe and liquid egg yolk that could be easily discerned quantitatively.

  7. A Rapid Detection Method of Brucella with Quantum Dots and Magnetic Beads Conjugated with Different Polyclonal Antibodies

    Science.gov (United States)

    Song, Dandan; Qu, Xiaofeng; Liu, Yushen; Li, Li; Yin, Dehui; Li, Juan; Xu, Kun; Xie, Renguo; Zhai, Yue; Zhang, Huiwen; Bao, Hao; Zhao, Chao; Wang, Juan; Song, Xiuling; Song, Wenzhi

    2017-03-01

    Brucella spp. are facultative intracellular bacteria that cause zoonotic disease of brucellosis worldwide. Traditional methods for detection of Brucella spp. take 48-72 h that does not meet the need of rapid detection. Herein, a new rapid detection method of Brucella was developed based on polyclonal antibody-conjugating quantum dots and antibody-modified magnetic beads. First, polyclonal antibodies IgG and IgY were prepared and then the antibody conjugated with quantum dots (QDs) and immunomagnetic beads (IMB), respectively, which were activated by N-(3-dimethylaminopropyl)- N'-ethylcar-bodiimide hydrochloride (EDC) and N-hydroxysuccinimide (NHS) to form probes. We used the IMB probe to separate the Brucella and labeled by the QD probe, and then detected the fluorescence intensity with a fluorescence spectrometer. The detection method takes 105 min with a limit of detection of 103 CFU/mL and ranges from 10 to 105 CFU/mL ( R 2 = 0.9983), and it can be well used in real samples.

  8. Rapid resolution of chronic shoulder pain classified as derangement using the McKenzie method: a case series.

    Science.gov (United States)

    Aytona, Maria Corazon; Dudley, Karlene

    2013-11-01

    The McKenzie method, also known as Mechanical Diagnosis and Therapy (MDT), is primarily recognized as an evaluation and treatment method for the spine. However, McKenzie suggested that this method could also be applied to the extremities. Derangement is an MDT classification defined as an anatomical disturbance in the normal resting position of the joint, and McKenzie proposed that repeated movements could be applied to reduce internal joint displacement and rapidly reduce derangement symptoms. However, the current literature on MDT application to shoulder disorders is limited. Here, we present a case series involving four patients with chronic shoulder pain from a duration of 2-18 months classified as derangement and treated using MDT principles. Each patient underwent mechanical assessment and was treated with repeated movements based on their directional preference. All patients demonstrated rapid and clinically significant improvement in baseline measures and the disabilities of the arm, shoulder, and hand (QuickDASH) scores from an average of 38% at initial evaluation to 5% at discharge within 3-5 visits. Our findings suggest that MDT may be an effective treatment approach for shoulder pain.

  9. Rapid Method for the Determination of 5-Hydroxymethylfurfural and Levulinic Acid Using a Double-Wavelength UV Spectroscopy

    Directory of Open Access Journals (Sweden)

    Junhua Zhang

    2013-01-01

    Full Text Available This study reports on a rapid method for the determination of levulinic acid (LA and 5-hydroxymethylfurfural (HMF in acid hydrolyze system of glucose based on UV spectroscopy. It was found that HMF and LA have a maximum absorption at the wavelengths of 284 nm and 266 nm, respectively, in a water medium, and the absorptions of HMF and LA at 284 nm and 266 nm follow Beer’s law very well. However, it was found that a major spectral interference species will arise in the quantification of HMF and LA; nonetheless, this interference can be eliminated through the absorption treatment of charcoal. Therefore, both HMF and LA can be quantified with a double-wavelength technique. The repeatability of the method had a relative standard deviation of less than 4.47% for HMF and 2.25% for LA; the limit of quantification (LOQ was 0.017 mmol/L for HMF and 4.68 mmol/L for LA, and the recovery ranged from 88% to 116% for HMF and from 94% to 105% for LA. The present method is simple, rapid, and accurate. It is suitable to use in the research of the preparation of HMF and LA in biorefinery area.

  10. Meselect – A rapid and effective method for the separation of the main leaf tissue types

    Directory of Open Access Journals (Sweden)

    Julia Svozil

    2016-11-01

    Full Text Available Individual tissues of complex eukaryotic organisms have specific gene expression programs that control their functions. Therefore, tissue-specific molecular information is required to increase our understanding of tissue-specific processes. Established methods in plants to obtain specific tissues or cell types from their organ or tissue context typically require the enzymatic degradation of cell walls followed by fluorescence-activated cell sorting (FACS using plants engineered for localized expression of green fluorescent protein (GFP. This has facilitated the acquisition of valuable data, mainly on root cell type-specific transcript and protein expression. However, FACS of different leaf cell types is difficult because of chlorophyll autofluorescence that interferes with the sorting process. Furthermore, the cell wall composition is different in each cell type. This results in long incubation times for refractory cell types, and cell sorting itself can take several hours. To overcome these limitations, we developed Meselect (mechanical separation of leaf compound tissues, a rapid and effective method for the separation of leaf epidermal, vascular and mesophyll tissues. Meselect is a novel combination of mechanical separation and rapid protoplasting, which benefits from the unique cell wall composition of the different tissue types. Meselect has several advantages over cell sorting: it does not require expensive equipment such as a cell sorter and does not depend on specific fluorescent reporter lines, the use of blenders as well as the inherent mixing of different cell types and of intact and damaged cells can be avoided, and the time between wounding of the leaf and freezing of the sample is short. The efficacy and specificity of the method to enrich the different leaf tissue types has been confirmed using Arabidopsis leaves, but it has also been successfully used for leaves of other plants such as tomato or cassava. The method is therefore

  11. A C. elegans-based foam for rapid on-site detection of residual live virus.

    Energy Technology Data Exchange (ETDEWEB)

    Negrete, Oscar A.; Branda, Catherine; Hardesty, Jasper O. E. (Sandia National Laboratories, Albuquerque, NM); Tucker, Mark David (Sandia National Laboratories, Albuquerque, NM); Kaiser, Julia N. (Global Product Management, Hilden, Germany); Kozina, Carol L.; Chirica, Gabriela S.

    2012-02-01

    In the response to and recovery from a critical homeland security event involving deliberate or accidental release of biological agents, initial decontamination efforts are necessarily followed by tests for the presence of residual live virus or bacteria. Such 'clearance sampling' should be rapid and accurate, to inform decision makers as they take appropriate action to ensure the safety of the public and of operational personnel. However, the current protocol for clearance sampling is extremely time-intensive and costly, and requires significant amounts of laboratory space and capacity. Detection of residual live virus is particularly problematic and time-consuming, as it requires evaluation of replication potential within a eukaryotic host such as chicken embryos. The intention of this project was to develop a new method for clearance sampling, by leveraging Sandia's expertise in the biological and material sciences in order to create a C. elegans-based foam that could be applied directly to the entire contaminated area for quick and accurate detection of any and all residual live virus by means of a fluorescent signal. Such a novel technology for rapid, on-site detection of live virus would greatly interest the DHS, DoD, and EPA, and hold broad commercial potential, especially with regard to the transportation industry.

  12. Rapid assessment of large scale vegetation change based on multi-temporal phenological analysis

    Science.gov (United States)

    Cai, Danlu; Guan, Yanning; Guo, Shan; Yan, Baoping; Xing, Zhi; Zhang, Chunyan; Piao, Yingchao; An, Xudong; Kang, Lihua

    2011-11-01

    Detecting vegetation change is critical for earth system and sustainability science. The existing methods, however, show several limitations, including inevitable selection of imagery acquisition dates, affection from vegetation related noise on temporal trajectory analysis, and assumptions due to vegetation classification model. This paper presents a multitemporal phenological frequency analysis over a relatively short period (MTPFA-SP) methodology to detect vegetation changes. This MTPFA-SP methodology bases on the amplitude components of fast Fourier transforming (FFT) and is implemented with two steps. First, NDVI time series over two periods are transformed with FFT into frequency domain, separately. Second, amplitude components with phenological information from Step 1 are selected for further change comparison. In this methodology, component selection shows physical meanings of natural vegetation process in frequency domain. Comparisons among those selected components help enhance the ability to rapidly detect vegetation changes. To validate this MTPFA-SP methodology, we detect changes between two periods (2001-2005 and 2006-2010) in the eastern Tibet Plateau area and make two kinds of assessments. The first is for a larger scale, including statistic analysis of altitudinal zonality and latitudinal zonality. The second assessment is for rapid detection of vegetation change location. Landsat TM image were employed to validate the result.

  13. Gold Nanorod-based Photo-PCR System for One-Step, Rapid Detection of Bacteria.

    Science.gov (United States)

    Kim, Jinjoo; Kim, Hansol; Park, Ji Ho; Jon, Sangyong

    2017-01-01

    The polymerase chain reaction (PCR) has been an essential tool for diagnosis of infectious diseases, but conventional PCR still has some limitations with respect to applications to point-of-care (POC) diagnostic systems that require rapid detection and miniaturization. Here we report a light-based PCR method, termed as photo-PCR, which enables rapid detection of bacteria in a single step. In the photo-PCR system, poly(enthylene glycol)-modified gold nanorods (PEG-GNRs), used as a heat generator, are added into the PCR mixture, which is subsequently periodically irradiated with a 808-nm laser to create thermal cycling. Photo-PCR was able to significantly reduce overall thermal cycling time by integrating bacterial cell lysis and DNA amplification into a single step. Furthermore, when combined with KAPA2G fast polymerase and cooling system, the entire process of bacterial genomic DNA extraction and amplification was further shortened, highlighting the potential of photo-PCR for use in a portable, POC diagnostic system.

  14. Development of a fluorescence-based sensor for rapid diagnosis of cyanide exposure.

    Science.gov (United States)

    Jackson, Randy; Oda, Robert P; Bhandari, Raj K; Mahon, Sari B; Brenner, Matthew; Rockwood, Gary A; Logue, Brian A

    2014-02-04

    Although commonly known as a highly toxic chemical, cyanide is also an essential reagent for many industrial processes in areas such as mining, electroplating, and synthetic fiber production. The "heavy" use of cyanide in these industries, along with its necessary transportation, increases the possibility of human exposure. Because the onset of cyanide toxicity is fast, a rapid, sensitive, and accurate method for the diagnosis of cyanide exposure is necessary. Therefore, a field sensor for the diagnosis of cyanide exposure was developed based on the reaction of naphthalene dialdehyde, taurine, and cyanide, yielding a fluorescent β-isoindole. An integrated cyanide capture "apparatus", consisting of sample and cyanide capture chambers, allowed rapid separation of cyanide from blood samples. Rabbit whole blood was added to the sample chamber, acidified, and the HCN gas evolved was actively transferred through a stainless steel channel to the capture chamber containing a basic solution of naphthalene dialdehyde (NDA) and taurine. The overall analysis time (including the addition of the sample) was cyanide exposure. Most importantly, the sensor was 100% accurate in diagnosing cyanide poisoning for acutely exposed rabbits.

  15. Applications of stereolithography for rapid prototyping of biologically compatible chip-based physiometers

    Science.gov (United States)

    Fuad, Nurul Mohd; Zhu, Feng; Kaslin, Jan; Wlodkowic, Donald

    2016-12-01

    Despite the growing demand and numerous applications for the biomedical community, the developments in millifluidic devices for small model organisms are limited compared to other fields of biomicrofluidics. The main reasons for this stagnanation are difficulties in prototyping of millimeter scale and high aspect ratio devices needed for large metazoan organisms. Standard photolithography is in this context a time consuming procedure not easily adapted for fabrication of molds with vertical dimensions above 1 mm. Moreover, photolithography is still largely unattainable to a gross majority of biomedical laboratories willing to pursue custom development of their own chip-based platforms due to costs and need for dedicated clean room facilities. In this work, we present application of high-definition additive manufacturing systems for fabrication of 3D printed moulds used in soft lithography. Combination of 3D printing with PDMS replica molding appears to be an alternative for millifluidic systems that yields rapid and cost effective prototyping pipeline. We investigated the important aspects on both 3D printed moulds and PDMS replicas such as geometric accuracies and surface topology. Our results demonstrated that SLA technologies could be applied for rapid and accurate fabrication of millifluidic devices for trapping of millimetre-sized specimens such as living zebrafish larvae. We applied the new manufacturing method in a proof-of-concept prototype device capable of trapping and immobilizing living zebrafish larvae for recording heart rate variation in cardio-toxicity experiments.

  16. Autoclave method for rapid preparation of bacterial PCR-template DNA.

    Science.gov (United States)

    Simmon, Keith E; Steadman, Dewey D; Durkin, Sarah; Baldwin, Amy; Jeffrey, Wade H; Sheridan, Peter; Horton, Rene; Shields, Malcolm S

    2004-02-01

    An autoclave method for preparing bacterial DNA for PCR template is presented, it eliminates the use of detergents, organic solvents, and mechanical cellular disruption approaches, thereby significantly reducing processing time and costs while increasing reproducibility. Bacteria are lysed by rapid heating and depressurization in an autoclave. The lysate, cleared by microcentrifugation, was either used directly in the PCR reaction, or concentrated by ultrafiltration. This approach was compared with seven established methods of DNA template preparation from four bacterial sources which included boiling Triton X-100 and SDS, bead beating, lysozyme/proteinase K, and CTAB lysis method components. Bacteria examined were Enterococcus and Escherichia coli, a natural marine bacterial community and an Antarctic cyanobacterial-mat. DNAs were tested for their suitability as PCR templates by repetitive element random amplified polymorphic DNA (RAPD) and denaturing gradient gel electrophoresis (DGGE) analysis. The autoclave method produced PCR amplifiable template comparable or superior to the other methods, with greater reproducibility, much shorter processing time, and at a significantly lower cost.

  17. Development of a micropulverized extraction method for rapid toxicological analysis of methamphetamine in hair.

    Science.gov (United States)

    Miyaguchi, Hajime; Kakuta, Masaya; Iwata, Yuko T; Matsuda, Hideaki; Tazawa, Hidekatsu; Kimura, Hiroko; Inoue, Hiroyuki

    2007-09-07

    We developed a rapid sample preparation method for the toxicological analysis of methamphetamine and amphetamine (the major metabolite of methamphetamine) in human hair by high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS), to facilitate fast screening and quantitation. Two milligrams of hair were mechanically micropulverized for 5 min in a 2-ml plastic tube together with 100 microl of an aqueous solvent containing 10% acetonitrile, 100 mM trifluoroacetic acid and the corresponding deuterium analogues as internal standards. The pulverizing highly disintegrated the hair components, simultaneously allowing the extraction of any drugs present in the hair. After filtering the suspension with a membrane-filter unit, the clear filtrate was directly analyzed by HPLC-MS/MS. No evaporation processes were required for sample preparation. Method optimization and validation study were carried out using real-case specimens and fortified samples in which the drugs had been artificially absorbed, respectively. Concentration ranges for quantitation were 0.040-125 and 0.040-25 ng/mg for methamphetamine and amphetamine, respectively. Real-case specimens were analyzed by the method presented here and by conventional ones to verify the applicability of our method to real-world analysis. Our method took less than 30 min for a set of chromatograms to be obtained from a washed hair sample.

  18. Kernel based eigenvalue-decomposition methods for analysing ham

    DEFF Research Database (Denmark)

    Christiansen, Asger Nyman; Nielsen, Allan Aasbjerg; Møller, Flemming

    2010-01-01

    methods, such as PCA, MAF or MNF. We therefore investigated the applicability of kernel based versions of these transformation. This meant implementing the kernel based methods and developing new theory, since kernel based MAF and MNF is not described in the literature yet. The traditional methods only...... have two factors that are useful for segmentation and none of them can be used to segment the two types of meat. The kernel based methods have a lot of useful factors and they are able to capture the subtle differences in the images. This is illustrated in Figure 1. You can see a comparison of the most...... conditions and finding useful additives to hinder the color to change rapidly. To be able to prove which methods of storing and additives work, Danisco wants to monitor the development of the color of meat in a slice of ham as a function of time, environment and ingredients. We have chosen to use multi...

  19. A Rapid Review of the Factors Affecting Healthcare Students' Satisfaction with Small-Group, Active Learning Methods.

    Science.gov (United States)

    Kilgour, James M; Grundy, Lisa; Monrouxe, Lynn V

    2016-01-01

    PHENOMENON: Problem-based learning (PBL) and other small-group, active learning methodologies have been widely adopted into undergraduate and postgraduate healthcare curricula across the world. Although much research has examined student perceptions of these innovative teaching pedagogies, there are still questions over which factors influence these views. This article aims to identify these key elements that affect healthcare student satisfaction with PBL and other small-group learning methods, including case-based and team-based learning. A systematic rapid review method was used to identify high-quality original research papers from the healthcare education literature from between 2009 and 2014. All papers were critically appraised before inclusion in line with published guidelines. Narrative synthesis was achieved using an inductively developed, thematic framework approach. Fifty-four papers were included in the narrative synthesis. The evidence suggests that, despite an initial period of negative emotion and anxiety, the perspectives of healthcare students toward small-group, active learning methods are generally positive. The key factors influencing this satisfaction level include (a) the facilitator role, (b) tutorial structure, (c) individual student factors, (d) case authenticity, (e) increased feedback, (f) group harmony, and (g) resource availability. Insights: Student satisfaction is an important determinant of healthcare education quality, and the findings of this review may be of value in future curriculum design. The evidence described here suggests that an ideal curriculum may be based on an expert-led, hybrid PBL model.

  20. A simple and rapid cultural method for detection of Enterobacter sakazakii in environmental samples

    NARCIS (Netherlands)

    Guillaume-Gentil, O.; Sonnard, V.; Kandhai, M.C.; Marugg, J.; Joosten, H.

    2005-01-01

    A method was developed to detect and identify Enterobacter sakazakii in environmental samples. The method is based on selective enrichment at 45 ± 0.5°C in lauryl sulfate tryptose broth supplemented with 0.5 M NaCl and 10 mg/liter vancomycin (mLST) for 22 to 24 h followed by streaking on tryptone

  1. [Rapid analysis on phenolic compounds in Rheum palmatum based on UPLC-Q-TOF/MSE combined with diagnostic ions filter].

    Science.gov (United States)

    Wang, Qing; Lu, Zhi-Wei; Liu, Yue-Hong; Wang, Ming-Ling; Fu, Shuang; Zhang, Qing-Qing; Zhao, Hui-Zhen; Zhang, Zhi-Xin; Xie, Zi-Ye; Huang, Zheng-Hai; Yu, Hong-Hong; Zhou, Wen-Juan; Gao, Xiao-Yan

    2017-05-01

    Diagnostic ions filter method was used to rapidly detect and identify the phenolic compounds in Rheum palmatum based on ultra performance liquid chromatography coupled with quadrupole time-of-flight mass spectrometry (UPLC-Q-TOF/MSE). The representative authentic standards of phenolic compounds, including gallic acid, (+)-catechin, (-)-epicatechin, (-)-epicatechin-3-O-gallate and procyanidin B2, were subjected to analysis by UPLC-Q-TOF/MSE system with negative ion mode. Fragmentation patterns of each standard were summarized based on assigned fragment ions. The prominent product ions were selected as diagnostic ions. Subsequently, diagnostic ions filter was employed to rapidly recognize analogous skeletons. Combined with retention time, accurate mass, characteristic fragments and previous literature data, the structures of the filtered compounds were identified or tentatively characterized. A total 63 phenolic compounds (36 phenolic acid derivatives, 8 flavonoid derivatives and 19 tennis derivatives) in R. palmatum were identified, including 6 potential new compounds. The method of diagnostic ions filter could rapidly detect and identify phenolic compounds in R. palmatum This study provides a method for rapid detection of phenolic compounds in R. palmatum and is expected to complete the material basis of rhubarb. Copyright© by the Chinese Pharmaceutical Association.

  2. Methodical bases of geodemographic forecasting

    Directory of Open Access Journals (Sweden)

    Катерина Сегіда

    2016-10-01

    Full Text Available The article deals with methodological features of the forecast of population size and composition. The essence and features of probabilistic demographic forecasting, methods, a component and dynamic ranks are considered; requirements to initial indicators for each type of the forecast are provided. It is noted that geo-demographic forecast is an important component of regional geo-demographic characteristic. Features of the demographic forecast development by component method (recursors of age are given, basic formulae of calculation, including the equation of demographic balance, a formula recursors taking into account gender and age indicators, survival coefficient are presented. The basic methodical principles of the demographic forecast are given by an extrapolation method (dynamic ranks, calculation features by means of the generalized indicators, such as extrapolation on the basis of indicators of an average pure gain, average growth rate and average rate of a gain are presented. To develop population forecast, the method of retrospective extrapolation (for the short-term forecast and a component method (for the mid-term forecast are mostly used. The example of such development by component method for gender and age structure of the population of Kharkiv region with step-by-step explanation of calculation is provided. The example of Kharkiv region’s population forecast development is provided by the method of dynamic ranks. Having carried out calculations of the main forecast indicators by administrative units, it is possible to determine features of further regional demographic development, to reveal internal territorial distinctions in demographic development. Application of separate forecasting methods allows to develop the forecast for certain indicators, however essential a variety, nonlinearity and not stationarity of the processes constituting demographic development forces to look +for new approaches and

  3. NATO Advanced Research Workshop, 19-22 May 1997: Rapid Method for Monitoring the Environment for Biological Hazards.

    Science.gov (United States)

    1997-05-22

    The NATO Advanced Research Workshop met for the purpose of bringing to light rapid methods for monitoring the environment for biological hazards such as biological warfare agents, naturally occurring diseases, detection and identification of different biological threats in the environment , dormancy in non-sporulating bacteria and bioluminescence techniques with respect to the rapid detection of microbes in air, water and food.

  4. A frame-based domain-specific language for rapid prototyping of FPGA-based software-defined radios

    Science.gov (United States)

    Ouedraogo, Ganda Stephane; Gautier, Matthieu; Sentieys, Olivier

    2014-12-01

    The field-programmable gate array (FPGA) technology is expected to play a key role in the development of software-defined radio (SDR) platforms. As this technology evolves, low-level designing methods for prototyping FPGA-based applications did not change throughout the decades. In the outstanding context of SDR, it is important to rapidly implement new waveforms to fulfill such a stringent flexibility paradigm. At the current time, different proposals have defined, through software-based approaches, some efficient methods to prototype SDR waveforms in a processor-based running environment. This paper describes a novel design flow for FPGA-based SDR applications. This flow relies upon high-level synthesis (HLS) principles and leverages the nascent HLS tools. Its entry point is a domain-specific language (DSL) which handles the complexity of programming an FPGA and integrates some SDR features so as to enable automatic waveform control generation from a data frame model. Two waveforms (IEEE 802.15.4 and IEEE 802.11a) have been designed and explored via this new methodology, and the results are highlighted in this paper.

  5. Rapid Assessment of Health Services in Punjab using a Mixed Method Approach

    Directory of Open Access Journals (Sweden)

    Rajesh Kumar

    2015-06-01

    Full Text Available Introduction: The out-of-pocket expenditure is quite high in Punjab. Hence, a rapid review of health facilities was undertaken to suggest remedial measures. Methods: Mixed method research approach was used to identify strengths and weaknesses of the health services in Punjab. All health institutions were included in the assessment from the three purposively sampled districts – one from each of the three regions of Punjab. Tools were developed to collect data from record review, observations, and in-depth interviews. Six building blocks framework proposed by the World Health Organization was used for data collection and analyses. Results: In general physical infrastructure, especially the buildings were found to be reasonably constructed at most of the healthcare facilities. However, the maintenance was not regular. The vacancies for general doctors, specialist doctors, nurses, and paramedics were 26%, 38%, 31% and 12% respectively. Supply of drugs was irregular and inadequate. A large proportion (45% of ‘user charges’ were spent on purchase of drugs and other consumables. Most registers were found to be updated, and reports were transmitted to higher levels usually on time. However, institutionalized system of monitoring and supervision was lacking. Govt. hospitals were providing in-patient care to about 35.5% of those who were estimated to need hospitalization. State had allocated about Rs. 1200 crores to health (0.46% of GDP, thus, spending only Rs. 433 per capita per year. Conclusions: Despite constraints, the government health service is catering to the needs of a large section of the population. Rapid health system assessment at periodic intervals using a mixed method approach can supplement routine monitoring of the health system.

  6. A Toolbox of Genetically Encoded FRET-Based Biosensors for Rapid l-Lysine Analysis

    Science.gov (United States)

    Steffen, Victoria; Otten, Julia; Engelmann, Susann; Radek, Andreas; Limberg, Michael; Koenig, Bernd W.; Noack, Stephan; Wiechert, Wolfgang; Pohl, Martina

    2016-01-01

    Background: The fast development of microbial production strains for basic and fine chemicals is increasingly carried out in small scale cultivation systems to allow for higher throughput. Such parallelized systems create a need for new rapid online detection systems to quantify the respective target compound. In this regard, biosensors, especially genetically encoded Förster resonance energy transfer (FRET)-based biosensors, offer tremendous opportunities. As a proof-of-concept, we have created a toolbox of FRET-based biosensors for the ratiometric determination of l-lysine in fermentation broth. Methods: The sensor toolbox was constructed based on a sensor that consists of an optimized central lysine-/arginine-/ornithine-binding protein (LAO-BP) flanked by two fluorescent proteins (enhanced cyan fluorescent protein (ECFP), Citrine). Further sensor variants with altered affinity and sensitivity were obtained by circular permutation of the binding protein as well as the introduction of flexible and rigid linkers between the fluorescent proteins and the LAO-BP, respectively. Results: The sensor prototype was applied to monitor the extracellular l-lysine concentration of the l-lysine producing Corynebacterium glutamicum (C. glutamicum) strain DM1933 in a BioLector® microscale cultivation device. The results matched well with data obtained by HPLC analysis and the Ninhydrin assay, demonstrating the high potential of FRET-based biosensors for high-throughput microbial bioprocess optimization. PMID:27690044

  7. A Toolbox of Genetically Encoded FRET-Based Biosensors for Rapid l-Lysine Analysis

    Directory of Open Access Journals (Sweden)

    Victoria Steffen

    2016-09-01

    Full Text Available Background: The fast development of microbial production strains for basic and fine chemicals is increasingly carried out in small scale cultivation systems to allow for higher throughput. Such parallelized systems create a need for new rapid online detection systems to quantify the respective target compound. In this regard, biosensors, especially genetically encoded Förster resonance energy transfer (FRET-based biosensors, offer tremendous opportunities. As a proof-of-concept, we have created a toolbox of FRET-based biosensors for the ratiometric determination of l-lysine in fermentation broth. Methods: The sensor toolbox was constructed based on a sensor that consists of an optimized central lysine-/arginine-/ornithine-binding protein (LAO-BP flanked by two fluorescent proteins (enhanced cyan fluorescent protein (ECFP, Citrine. Further sensor variants with altered affinity and sensitivity were obtained by circular permutation of the binding protein as well as the introduction of flexible and rigid linkers between the fluorescent proteins and the LAO-BP, respectively. Results: The sensor prototype was applied to monitor the extracellular l-lysine concentration of the l-lysine producing Corynebacterium glutamicum (C. glutamicum strain DM1933 in a BioLector® microscale cultivation device. The results matched well with data obtained by HPLC analysis and the Ninhydrin assay, demonstrating the high potential of FRET-based biosensors for high-throughput microbial bioprocess optimization.

  8. A Toolbox of Genetically Encoded FRET-Based Biosensors for Rapid l-Lysine Analysis.

    Science.gov (United States)

    Steffen, Victoria; Otten, Julia; Engelmann, Susann; Radek, Andreas; Limberg, Michael; Koenig, Bernd W; Noack, Stephan; Wiechert, Wolfgang; Pohl, Martina

    2016-09-28

    Background: The fast development of microbial production strains for basic and fine chemicals is increasingly carried out in small scale cultivation systems to allow for higher throughput. Such parallelized systems create a need for new rapid online detection systems to quantify the respective target compound. In this regard, biosensors, especially genetically encoded Förster resonance energy transfer (FRET)-based biosensors, offer tremendous opportunities. As a proof-of-concept, we have created a toolbox of FRET-based biosensors for the ratiometric determination of l-lysine in fermentation broth. Methods: The sensor toolbox was constructed based on a sensor that consists of an optimized central lysine-/arginine-/ornithine-binding protein (LAO-BP) flanked by two fluorescent proteins (enhanced cyan fluorescent protein (ECFP), Citrine). Further sensor variants with altered affinity and sensitivity were obtained by circular permutation of the binding protein as well as the introduction of flexible and rigid linkers between the fluorescent proteins and the LAO-BP, respectively. Results: The sensor prototype was applied to monitor the extracellular l-lysine concentration of the l-lysine producing Corynebacterium glutamicum (C. glutamicum) strain DM1933 in a BioLector(®) microscale cultivation device. The results matched well with data obtained by HPLC analysis and the Ninhydrin assay, demonstrating the high potential of FRET-based biosensors for high-throughput microbial bioprocess optimization.

  9. A simple and rapid chromatographic method to determine unauthorized basic colorants (rhodamine B, auramine O, and pararosaniline) in processed foods

    Science.gov (United States)

    Tatebe, Chiye; Zhong, Xining; Ohtsuki, Takashi; Kubota, Hiroki; Sato, Kyoko; Akiyama, Hiroshi

    2014-01-01

    A simple and rapid high-performance liquid chromatography (HPLC) method to determine basic colorants such as pararosaniline (PA), auramine O (AO), and rhodamine B (RB) in various processed foods was developed. Linearity of the calibration curves ranged from 0.05 to 50 μg/mL for PA and 0.05–100 μg/mL for AO and RB. The detection and quantification limits (LOD and LOQ) of the basic colorants, which were evaluated as signal-to-noise ratios of 3 for LOD and 10 for LOQ, ranged from 0.0125 to 0.05 and 0.025 to 0.125 μg/g, respectively. The recoveries and relative standard deviations of three basic colorants in six processed foods, namely, chili sauce, curry paste, gochujang (hot pepper paste), tandoori chicken (roasted chicken prepared with yogurt and spices), powder soup, and shrimp powder ranged from 70.2% to 102.8% and 0.8% to 8.0%, respectively. The intraday precision of the recovery test ranged from 1.7% to 4.5%, whereas the interday precision ranged from 3.7% to 7.7%. The reported method has been successfully applied to basic colorant determination in various processed foods such as fat-based food matrices (curry paste and tandoori chicken), chili products (gochujang and chili sauce), and protein-based products (shrimp powder and powder soup). Thin layer chromatography and liquid chromatography/mass spectrometry methods for the determination of basic colorants in processed foods were also developed for rapid analysis and identification, respectively. These methods are very useful for monitoring unauthorized basic colorants in inspection centers or quarantine laboratories in many countries. PMID:25473512

  10. Towards a method of rapid extraction of strontium-90 from urine: urine pretreatment and alkali metal removal

    Energy Technology Data Exchange (ETDEWEB)

    Hawkins, C. [Argonne National Lab. (ANL), Argonne, IL (United States); Dietz, M. [Argonne National Lab. (ANL), Argonne, IL (United States); Kaminski, M. [Argonne National Lab. (ANL), Argonne, IL (United States); Mertz, C. [Argonne National Lab. (ANL), Argonne, IL (United States); Shkrob, I. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2016-03-01

    A technical program to support the Centers of Disease Control and Prevention is being developed to provide an analytical method for rapid extraction of Sr-90 from urine, with the intent of assessing the general population’s exposure during an emergency response to a radiological terrorist event. Results are presented on the progress in urine sample preparation and chemical separation steps that provide an accurate and quantitative detection of Sr-90 based upon an automated column separation sequence and a liquid scintillation assay. Batch extractions were used to evaluate the urine pretreatment and the column separation efficiency and loading capacity based upon commercial, extractant-loaded resins. An efficient pretreatment process for decolorizing and removing organics from urine without measurable loss of radiostrontium from the sample was demonstrated. In addition, the Diphonix® resin shows promise for the removal of high concentrations of common strontium interferents in urine as a first separation step for Sr-90 analysis.

  11. Rapid Hydrothermal Synthesis of Zinc Oxide Nanowires by Annealing Methods on Seed Layers

    Directory of Open Access Journals (Sweden)

    Jang Bo Shim

    2011-01-01

    Full Text Available Well-aligned zinc oxide (ZnO nanowire arrays were successfully synthesized on a glass substrate using the rapid microwave heating process. The ZnO seed layers were produced by spinning the precursor solutions onto the substrate. Among coatings, the ZnO seed layers were annealed at 100°C for 5 minutes to ensure particle adhesion to the glass surface in air, nitrogen, and vacuum atmospheres. The annealing treatment of the ZnO seed layer was most important for achieving the high quality of ZnO nanowire arrays as ZnO seed nanoparticles of larger than 30 nm in diameter evolve into ZnO nanowire arrays. Transmission electron microscopy analysis revealed a single-crystalline lattice of the ZnO nanowires. Because of their low power (140 W, low operating temperatures (90°C, easy fabrication (variable microwave sintering system, and low cost (90% cost reduction compared with gas condensation methods, high quality ZnO nanowires created with the rapid microwave heating process show great promise for use in flexible solar cells and flexible display devices.

  12. A Rapid and Efficient Method for Evaluation of Suspect Testimony: Palynological Scanning.

    Science.gov (United States)

    Wiltshire, Patricia E J; Hawksworth, David L; Edwards, Kevin J

    2015-11-01

    A rapid method for evaluating suspect testimony is valuable at any stage in an inquiry and can result in a change of direction in an investigation. Rape cases, in particular, can present problems where a defendant renders DNA analysis redundant by claiming that the claimant consented to have sexual relations. Forensic palynology is valuable in confirming or eliminating locations as being crime scenes, thus checking the testimony of both parties. In contrast to some forensic disciplines, forensic palynology can provide critical information without time-consuming full analysis. Two cases are described where the palynological assemblages from comparator samples of pertinent places were compared with those obtained from clothing of claimants and defendants. The results of rapid microscopical scanning of relevant preparations led to early confessions, thus obviating the need for costly analyses and protracted court proceedings. A third case demonstrates the unbiased nature of this technique where a man, although innocent of any offense, lied about having visited the crime scene for fear of prosecution. This highlights the need for sensitive policing in claims of rape. © 2015 American Academy of Forensic Sciences.

  13. Performance of a Micro-UAV lifting system built with the usage of rapid prototyping methods

    Science.gov (United States)

    Dalewski, R. T.; Gumowski, K.; Barczak, T.; Godek, J.

    2014-08-01

    This article presents results of the aerodynamic testing of a micro unmanned aerial vehicle rotor efficiency. The rotors were prepared as a set of two rotors in a counter-rotating ducted drive. Prototypes of the drives were made using two rapid prototyping techniques - FDM - fused deposition modelling method and SLS - selective laser sintering. Rotors were made then treated by introducing additional finishing cyanoacrylate coating and abrasive processing. Main differences between those models were observed in fan shape, porosity, surface roughness and mechanical properties - stiffness. An influence of these factors was observed on an aerodynamic efficiency. For the obtained prototypes both simulations and experimental testing were conducted with thrust, power, torque measurements, as well as the measurement of velocity and pressure distribution at the outlet of the duct. The results show the possibility of using rapid prototyping techniques to produce prototypes of drives operating in the low and medium Reynolds numbers (6000-60000), and the aerodynamic shape relevant factors affecting the preparation and performance of such drives. In addition, simulation studies were performed using the Fluent environment where experimental results were confronted with the results of simulation studies.

  14. A Rapid Dialysis Method for Analysis of Artificial Sweeteners in Foods (2nd Report).

    Science.gov (United States)

    Tahara, Shoichi; Yamamoto, Sumiyo; Yamajima, Yukiko; Miyakawa, Hiroyuki; Uematsu, Yoko; Monma, Kimio

    2017-01-01

    Following the previous report, a rapid dialysis method was developed for the extraction and purification of four artificial sweeteners, namely, sodium saccharide (Sa), acesulfame potassium (AK), aspartame (APM), and dulcin (Du), which are present in various foods. The method was evaluated by the addition of 0.02 g/kg of these sweeteners to a cookie sample, in the same manner as in the previous report. Revisions from the previous method were: reduction of the total dialysis volume from 200 to 100 mL, change of tube length from 55 to 50 cm, change of dialysate from 0.01 mol/L hydrochloric aqueous solution containing 10% sodium chloride to 30% methanol solution, and change of dialysis conditions from ambient temperature with occasional shaking to 50℃ with shaking at 160 rpm. As a result of these revisions, the recovery reached 99.3-103.8% with one hour dialysis. The obtained recovery yields were comparable to the recovery yields in the previous method with four hour dialysis.

  15. ReagentTF: a rapid and versatile optical clearing method for biological imaging(Conference Presentation)

    Science.gov (United States)

    Yu, Tingting; Zhu, Jingtan; Li, Yusha; Qi, Yisong; Xu, Jianyi; Gong, Hui; Luo, Qingming; Zhu, Dan

    2017-02-01

    The emergence of various optical clearing methods provides a great potential for imaging deep inside tissues by combining with multiple-labelling and microscopic imaging techniques. They were generally developed for specific imaging demand thus presented some non-negligible limitations such as long incubation time, tissue deformation, fluorescence quenching, incompatibility with immunostaining or lipophilic tracers. In this study, we developed a rapid and versatile clearing method, termed ReagentTF, for deep imaging of various fluorescent samples. This method can not only efficiently clear embryos, neonatal whole-brains and adult thick brain sections by simple immersion in aqueous mixtures with minimal volume change, but also can preserve fluorescence of various fluorescent proteins and simultaneously be compatible with immunostaining and lipophilic neuronal dyes. We demonstrate the effectiveness of this method in reconstructing the cell distributions of mouse hippocampus, visualizing the neural projection from CA1 (Cornu Ammonis 1) to HDB (nucleus of the horizontal limb of the diagonal band), and observing the growth of forelimb plexus in whole-mount embryos. These results suggest that ReagentTF is useful for large-volume imaging and will be an option for the deep imaging of biological tissues.

  16. A simple and rapid method to characterize lipid fate in skeletal muscle.

    Science.gov (United States)

    Massart, Julie; Zierath, Juleen R; Chibalin, Alexander V

    2014-06-24

    Elevated fatty acids contribute to the development of type 2 diabetes and affect skeletal muscle insulin sensitivity. Since elevated intramuscular lipids and insulin resistance is strongly correlated, aberrant lipid storage or lipid intermediates may be involved in diabetes pathogenesis. The aim of this study was to develop a method to determine the dynamic metabolic fate of lipids in primary human skeletal muscle cells and in intact mouse skeletal muscle. We report a simple and fast method to characterize lipid profiles in skeletal muscle using thin layer chromatography. The described method was specifically developed to assess lipid utilization in cultured and intact skeletal muscle. We determined the effect of a pan-diacylglycerol kinase (DGK) class I inhibitor (R59949) on lipid metabolism to validate the method. In human skeletal muscle cells, DGK inhibition impaired diacylglycerol (DAG) conversion to phosphatidic acid and increased triglyceride synthesis. In intact glycolytic mouse skeletal muscle, DGK inhibition triggered the accumulation of DAG species. Conversely, the DGK inhibitor did not affect DAG content in oxidative muscle. This simple assay detects rapid changes in the lipid species composition of skeletal muscle with high sensitivity and specificity. Determination of lipid metabolism in skeletal muscle may further elucidate the mechanisms contributing to the pathogenesis of insulin resistance in type 2 diabetes or obesity.

  17. Statistical Methods for Base Inflation Calculation

    Directory of Open Access Journals (Sweden)

    Ion Partachi

    2007-02-01

    Full Text Available The purposes of the given research are the analysis of four alternative methods of measurement of base inflation and a choice of the parameter most precisely reflecting an actual inflationary trend in the Republic of Moldova. The estimation of the fact sheet on inflation in the Republic of Moldova is made with application of the approach based on methods of the statistical analysis, in particular: exclusion method, trimmed means method, standard deviation trimmed means method, percentile method.

  18. Clinical application of a rapid microbiological test based on capillary zone electrophoresis to assess local skin infection

    Directory of Open Access Journals (Sweden)

    Szeliga Jacek

    2011-10-01

    Full Text Available Abstract Background The basic clinical problem associated with infection treatment is the fact that classic, commonly and routinely used isolation and identification methods are based on long-term processes of a phenotypic analysis of microorganisms. Consequently sometimes, especially in small centres, rapid implementation of antibacterial treatment becomes delayed. The work presents the initial results of rapid microbiological identification based on an original method of capillary zone electrophoresis (CZE. The study involved the analysis of 78 biological samples from post-operative wounds and trophic ulcers. Results The attempt was made to identify individual bacterial species based on characteristic features of electropherograms achieved. Finally, G(+ cocci type bacteria and different G(- rods were identified with sensitivity of 88.1% and specificity of 100%. Conclusions Based on the clinical trials using an electrophoretic technique in the field of microbiological diagnostics of infected exudate from a post-operative wound it can be concluded that it is a rapid and relatively sensitive method for initial identification of infectious pathogens.

  19. Rapid and simple methods for quantitative analysis of some antidepressant in pharmaceutical formulations by using first derivative spectrophotometry and HPLC.

    Science.gov (United States)

    Erk, Nevin

    2003-12-01

    Two rapid, simple and accurate first derivative spectrophotometry and HPLC method for the determination of nefazodone hydrochloride and sertraline hydrochloride in pharmaceutical formulations are discussed. The first one is a derivative spectrophotometric procedure and the second one is based on a HPLC method with a UV detector. In the first method, first derivative spectrophotometry, nefazodone hydrochloride or sertraline hydrochloride by measurement of their first derivative signals at 241.8-256.7 nm (peak-to-peak amplitude), or 271.6-275.5 nm (peak-to-peak amplitude), respectively. Calibration graphs were established for 10.0-42.0 microg ml(-1) nefazodone hydrochloride, or 8.0-46.0 microg ml(-1) sertraline hydrochloride. In the other method, HPLC, the UV detection was carried out at 265.0 nm (nefazodone hydrochloride) and 270.0 nm (sertraline hydrochloride). The samples were chromatographed on a Supercosil RP-18 column. The mobile phases were methanol:acetonitrile:phosphate buffer at pH 5.5 (10:50:40 v/v/v) (nefazodone hydrochloride) and methanol:phosphate buffer at pH 4.5 (20:80 v/v) (sertraline hydrochloride). The results obtained from first derivative spectrophotometric method were comparable with those obtained by using HPLC. It was concluded that both the developed methods are equally accurate, sensitive, and precision could be applied directly and easily to the pharmaceutical formulations of nefazodone hydrochloride and sertraline hydrochloride, respectively.

  20. Rapid and efficient filtration-based procedure for separation and safe analysis of CBRN mixed samples.

    Directory of Open Access Journals (Sweden)

    Mostafa Bentahir

    Full Text Available Separating CBRN mixed samples that contain both chemical and biological warfare agents (CB mixed sample in liquid and solid matrices remains a very challenging issue. Parameters were set up to assess the performance of a simple filtration-based method first optimized on separate C- and B-agents, and then assessed on a model of CB mixed sample. In this model, MS2 bacteriophage, Autographa californica nuclear polyhedrosis baculovirus (AcNPV, Bacillus atrophaeus and Bacillus subtilis spores were used as biological agent simulants whereas ethyl methylphosphonic acid (EMPA and pinacolyl methylphophonic acid (PMPA were used as VX and soman (GD nerve agent surrogates, respectively. Nanoseparation centrifugal devices with various pore size cut-off (30 kD up to 0.45 µm and three RNA extraction methods (Invisorb, EZ1 and Nuclisens were compared. RNA (MS2 and DNA (AcNPV quantification was carried out by means of specific and sensitive quantitative real-time PCRs (qPCR. Liquid chromatography coupled to time-of-flight mass spectrometry (LC/TOFMS methods was used for quantifying EMPA and PMPA. Culture methods and qPCR demonstrated that membranes with a 30 kD cut-off retain more than 99.99% of biological agents (MS2, AcNPV, Bacillus Atrophaeus and Bacillus subtilis spores tested separately. A rapid and reliable separation of CB mixed sample models (MS2/PEG-400 and MS2/EMPA/PMPA contained in simple liquid or complex matrices such as sand and soil was also successfully achieved on a 30 kD filter with more than 99.99% retention of MS2 on the filter membrane, and up to 99% of PEG-400, EMPA and PMPA recovery in the filtrate. The whole separation process turnaround-time (TAT was less than 10 minutes. The filtration method appears to be rapid, versatile and extremely efficient. The separation method developed in this work constitutes therefore a useful model for further evaluating and comparing additional separation alternative procedures for a safe handling and

  1. Rapid and Efficient Filtration-Based Procedure for Separation and Safe Analysis of CBRN Mixed Samples

    Science.gov (United States)

    Bentahir, Mostafa; Laduron, Frederic; Irenge, Leonid; Ambroise, Jérôme; Gala, Jean-Luc

    2014-01-01

    Separating CBRN mixed samples that contain both chemical and biological warfare agents (CB mixed sample) in liquid and solid matrices remains a very challenging issue. Parameters were set up to assess the performance of a simple filtration-based method first optimized on separate C- and B-agents, and then assessed on a model of CB mixed sample. In this model, MS2 bacteriophage, Autographa californica nuclear polyhedrosis baculovirus (AcNPV), Bacillus atrophaeus and Bacillus subtilis spores were used as biological agent simulants whereas ethyl methylphosphonic acid (EMPA) and pinacolyl methylphophonic acid (PMPA) were used as VX and soman (GD) nerve agent surrogates, respectively. Nanoseparation centrifugal devices with various pore size cut-off (30 kD up to 0.45 µm) and three RNA extraction methods (Invisorb, EZ1 and Nuclisens) were compared. RNA (MS2) and DNA (AcNPV) quantification was carried out by means of specific and sensitive quantitative real-time PCRs (qPCR). Liquid chromatography coupled to time-of-flight mass spectrometry (LC/TOFMS) methods was used for quantifying EMPA and PMPA. Culture methods and qPCR demonstrated that membranes with a 30 kD cut-off retain more than 99.99% of biological agents (MS2, AcNPV, Bacillus Atrophaeus and Bacillus subtilis spores) tested separately. A rapid and reliable separation of CB mixed sample models (MS2/PEG-400 and MS2/EMPA/PMPA) contained in simple liquid or complex matrices such as sand and soil was also successfully achieved on a 30 kD filter with more than 99.99% retention of MS2 on the filter membrane, and up to 99% of PEG-400, EMPA and PMPA recovery in the filtrate. The whole separation process turnaround-time (TAT) was less than 10 minutes. The filtration method appears to be rapid, versatile and extremely efficient. The separation method developed in this work constitutes therefore a useful model for further evaluating and comparing additional separation alternative procedures for a safe handling and

  2. Longitudinal analysis of the temporal evolution of Acinetobacter baumannii strains in Ohio, USA, by using rapid automated typing methods.

    Directory of Open Access Journals (Sweden)

    Brooke K Decker

    Full Text Available Genotyping methods are essential to understand the transmission dynamics of Acinetobacter baumannii. We examined the representative genotypes of A. baumannii at different time periods in select locations in Ohio, using two rapid automated typing methods: PCR coupled with electrospray ionization mass spectrometry (PCR/ESI-MS, a form of multi-locus sequence typing (MLST, and repetitive-sequence-based-PCR (rep-PCR. Our analysis included 122 isolates from 4 referral hospital systems, in 2 urban areas of Ohio. These isolates were associated with outbreaks at 3 different time periods (1996, 2000 and 2005-2007. Type assignments of PCR/ESI-MS and rep-PCR were compared to each other and to worldwide (WW clone types. The discriminatory power of each method was determined using the Simpson's index of diversity (DI. We observed that PCR/ESI-MS sequence type (ST 14, corresponding to WW clone 3, predominated in 1996, whereas ST 12 and 14 co-existed in the intermediate period (2000 and ST 10 and 12, belonging to WW clone 2, predominated more recently in 2007. The shift from WW clone 3 to WW clone 2 was accompanied by an increase in carbapenem resistance. The DI was approximately 0.74 for PCR/ESI-MS, 0.88 for rep-PCR and 0.90 for the combination of both typing methods. We conclude that combining rapid automated typing methods such as PCR/ESI-MS and rep-PCR serves to optimally characterize the regional molecular epidemiology of A. baumannii. Our data also sheds light on the changing sequence types in an 11 year period in Northeast Ohio.

  3. A new rapid method for Clostridium difficile DNA extraction and detection in stool: toward point-of-care diagnostic testing

    National Research Council Canada - National Science Library

    Freifeld, Alison G; Simonsen, Kari A; Booth, Christine S; Zhao, Xing; Whitney, Scott E; Karre, Teresa; Iwen, Peter C; Viljoen, Hendrik J

    2012-01-01

    We describe a new method for the rapid diagnosis of Clostridium difficile infection, with stool sample preparation and DNA extraction by heat and physical disruption in a single-use lysis microreactor (LMR...

  4. Apparatus and method for rapid cooling of large area substrates in vacuum

    Science.gov (United States)

    Barth, Kurt L.; Enzenroth, Robert A.; Sampath, Walajabad S.

    2010-09-28

    The present invention is directed to an apparatus and method for rapid cooling of a large substrate in a vacuum environment. A first cooled plate is brought into close proximity with one surface of a flat substrate. The spatial volume between the first cooling plate and the substrate is sealed and brought to a higher pressure than the surrounding vacuum level to increase the cooling efficiency. A second cooled plate is brought into close proximity with the opposite surface of the flat substrate. A second spatial volume between the second cooling plate and the substrate is sealed and the gas pressure is equalized to the gas pressure in the first spatial volume. The equalization of the gas pressure on both sides of the flat substrate eliminates deflection of the substrate and bending stress in the substrate.

  5. A rapid and economic in-house DNA purification method using glass syringe filters.

    Directory of Open Access Journals (Sweden)

    Yun-Cheol Kim

    Full Text Available BACKGROUND: Purity, yield, speed and cost are important considerations in plasmid purification, but it is difficult to achieve all of these at the same time. Currently, there are many protocols and kits for DNA purification, however none maximize all four considerations. METHODOLOGY/PRINCIPAL FINDINGS: We now describe a fast, efficient and economic in-house protocol for plasmid preparation using glass syringe filters. Plasmid yield and quality as determined by enzyme digestion and transfection efficiency were equivalent to the expensive commercial kits. Importantly, the time required for purification was much less than that required using a commercial kit. CONCLUSIONS/SIGNIFICANCE: This method provides DNA yield and quality similar to that obtained with commercial kits, but is more rapid and less costly.

  6. A robust and rapid method of producing soluble, stable, and functional G-protein coupled receptors.

    Directory of Open Access Journals (Sweden)

    Karolina Corin

    Full Text Available Membrane proteins, particularly G-protein coupled receptors (GPCRs, are notoriously difficult to express. Using commercial E. coli cell-free systems with the detergent Brij-35, we could rapidly produce milligram quantities of 13 unique GPCRs. Immunoaffinity purification yielded receptors at >90% purity. Secondary structure analysis using circular dichroism indicated that the purified receptors were properly folded. Microscale thermophoresis, a novel label-free and surface-free detection technique that uses thermal gradients, showed that these receptors bound their ligands. The secondary structure and ligand-binding results from cell-free produced proteins were comparable to those expressed and purified from HEK293 cells. Our study demonstrates that cell-free protein production using commercially available kits and optimal detergents is a robust technology that can be used to produce sufficient GPCRs for biochemical, structural, and functional analyses. This robust and simple method may further stimulate others to study the structure and function of membrane proteins.

  7. Rapid method for surveying CO concentrations in high-rise buildings

    Energy Technology Data Exchange (ETDEWEB)

    Flachsbart, P.G.; Ott, W.R.

    1986-01-01

    A rapid method for employing personal exposure monitors (PEMs) to measure carbon monoxide (CO) concentrations in high-rise buildings is described. The purpose is to determine whether or not a CO problem exists in a building, and, if so, what corrective actions should be taken. The methodology was applied to a 15-story building in Palo Alto, CA, where elevated CO concentrations were discovered on the first 11 floors. The source appeared to be an underground parking garage. A follow-up survey four years later revealed that mitigative measures designed to reduce these concentrations had been successful. The survey methodology is inexpensive and can be applied to a number of buildings in a city.

  8. Method to Rapidly Collect Thousands of Velocity Observations to Validate Million-Element 2D Hydrodynamic Models

    Science.gov (United States)

    Barker, J. R.; Pasternack, G. B.; Bratovich, P.; Massa, D.; Reedy, G.; Johnson, T.

    2010-12-01

    Two-dimensional (depth-averaged) hydrodynamic models have existed for decades and are used to study a variety of hydrogeomorphic processes as well as to design river rehabilitation projects. Rapid computer and coding advances are revolutionizing the size and detail of 2D models. Meanwhile, advances in topo mapping and environmental informatics are providing the data inputs to drive large, detailed simulations. Million-element computational meshes are in hand. With simulations of this size and detail, the primary challenge has shifted to finding rapid and inexpensive means for testing model predictions against observations. Standard methods for collecting velocity data include boat-mounted ADCP and point-based sensors on boats or wading rods. These methods are labor intensive and often limited to a narrow flow range. Also, they generate small datasets at a few cross-sections, which is inadequate to characterize the statistical structure of the relation between predictions and observations. Drawing on the long-standing oceanographic method of using drogues to track water currents, previous studies have demonstrated the potential of small dGPS units to obtain surface velocity in rivers. However, dGPS is too inaccurate to test 2D models. Also, there is financial risk in losing drogues in rough currents. In this study, an RTK GPS unit was mounted onto a manned whitewater kayak. The boater positioned himself into the current and used floating debris to maintain a speed and heading consistent with the ambient surface flow field. RTK GPS measurements were taken ever 5 sec. From these positions, a 2D velocity vector was obtained. The method was tested over ~20 km of the lower Yuba River in California in flows ranging from 500-5000 cfs, yielding 5816 observations. To compare velocity magnitude against the 2D model-predicted depth-averaged value, kayak-based surface values were scaled down by an optimized constant (0.72), which had no negative effect on regression analysis

  9. Evaluation of rapid alternative methods for drug susceptibility testing in clinical isolates of Mycobacterium tuberculosis

    Directory of Open Access Journals (Sweden)

    Luciano Mengatto

    2006-08-01

    Full Text Available A study was carried out to compare the performance of a commercial method (MGIT and four inexpensive drug susceptibility methods: nitrate reductase assay (NRA, microscopic observation drug susceptibility (MODS assay, MTT test, and broth microdilution method (BMM. A total of 64 clinical isolates of Mycobacterium tuberculosis were studied. The Lowenstein-Jensen proportion method (PM was used as gold standard. MGIT, NRA, MODS, and MTT results were available on an average of less than 10 days, whereas BMM results could be reported in about 20 days. Most of the evaluated tests showed excellent performance for isoniazid and rifampicin, with sensitivity and specificity values > 90%. With most of the assays, sensitivity for ethambutol was low (62-87% whereas for streptomycin, sensitivity values ranged from 84 to 100%; NRA-discrepancies were associated with cultures with a low proportion of EMB-resistant organisms while most discrepancies with quantitative tests (MMT and BMM were seen with isolates whose minimal inhibitory concentrations fell close the cutoff. MGIT is reliable but still expensive. NRA is the most inexpensive and easiest method to perform without changing the organization of the routine PM laboratory performance. While MODS, MTT, and BMM, have the disadvantage from the point of view of biosafety, they offer the possibility of detecting partial resistant strains. This study shows a very good level of agreement of the four low-cost methods compared to the PM for rapid detection of isoniazid, rifampicin and streptomycin resistance (Kappa values > 0.8; more standardization is needed for ethambutol.

  10. A rapid and efficient method for assessing pathogenicity of ustilago maydis on maize and teosinte lines.

    Science.gov (United States)

    Chavan, Suchitra; Smith, Shavannor M

    2014-01-03

    Maize is a major cereal crop worldwide. However, susceptibility to biotrophic pathogens is the primary constraint to increasing productivity. U. maydis is a biotrophic fungal pathogen and the causal agent of corn smut on maize. This disease is responsible for significant yield losses of approximately $1.0 billion annually in the U.S.(1) Several methods including crop rotation, fungicide application and seed treatments are currently used to control corn smut(2). However, host resistance is the only practical method for managing corn smut. Identification of crop plants including maize, wheat, and rice that are resistant to various biotrophic pathogens has significantly decreased yield losses annually(3-5). Therefore, the use of a pathogen inoculation method that efficiently and reproducibly delivers the pathogen in between the plant leaves, would facilitate the rapid identification of maize lines that are resistant to U. maydis. As, a first step toward indentifying maize lines that are resistant to U. maydis, a needle injection inoculation method and a resistance reaction screening method was utilized to inoculate maize, teosinte, and maize x teosinte introgression lines with a U. maydis strain and to select resistant plants. Maize, teosinte and maize x teosinte introgression lines, consisting of about 700 plants, were planted, inoculated with a strain of U. maydis, and screened for resistance. The inoculation and screening methods successfully identified three teosinte lines resistant to U. maydis. Here a detailed needle injection inoculation and resistance reaction screening protocol for maize, teosinte, and maize x teosinte introgression lines is presented. This study demonstrates that needle injection inoculation is an invaluable tool in agriculture that can efficiently deliver U. maydis in between the plant leaves and has provided plant lines that are resistant to U. maydis that can now be combined and tested in breeding programs for improved disease resistance.

  11. [Application status of rapid prototyping technology in artificial bone based on reverse engineering].

    Science.gov (United States)

    Fang, Ao; Zheng, Min; Fan, Ding

    2015-02-01

    Artificial bone replacement has made an important contribution to safeguard human health and improve the quality of life. The application requirements of rapid prototyping technology based on reverse engineering in individualized artificial bone with individual differences are particularly urgent. This paper reviewed the current research and applications of rapid prototyping and reverse engineering in artificial bone. The research developments and the outlook of bone kinematics and dynamics simulation are also introduced.

  12. A rapid method of fruit cell isolation for cell size and shape measurements

    Directory of Open Access Journals (Sweden)

    Johnston Jason W

    2009-04-01

    Full Text Available Abstract Background Cell size is a structural component of fleshy fruit, contributing to important traits such as fruit size and texture. There are currently a number of methods for measuring cell size; most rely either on tissue sectioning or digestion of the tissue with cell wall degrading enzymes or chemicals to release single cells. Neither of these approaches is ideal for assaying large fruit numbers as both require a considerable time to prepare the tissue, with current methods of cell wall digestions taking 24 to 48 hours. Additionally, sectioning can lead to a measurement of a plane that does not represent the widest point of the cell. Results To develop a more rapid way of measuring fruit cell size we have developed a protocol that solubilises pectin in the middle lamella of the plant cell wall releasing single cells into a buffered solution. Gently boiling small fruit samples in a 0.05 M Na2CO3 solution, osmotically balanced with 0.3 M mannitol, produced good cell separation with little cellular damage in less than 30 minutes. The advantage of combining a chemical treatment with boiling is that the cells are rapidly killed. This stopped cell shape changes that could potentially occur during separation. With this method both the rounded and angular cells of the apple cultivars SciRos 'Pacific Rose' and SciFresh 'Jazz'™ were observed in the separated cells. Using this technique, an in-depth analysis was performed measuring cell size from 5 different apple cultivars. Cell size was measured using the public domain ImageJ software. For each cultivar a minimum of 1000 cells were measured and it was found that each cultivar displayed a different distribution of cell size. Cell size within cultivars was similar and there was no correlation between flesh firmness and cell size. This protocol was tested on tissue from other fleshy fruit including tomato, rock melon and kiwifruit. It was found that good cell separation was achieved with flesh

  13. Effects of Hydrocarbon-Based Grease on Rapid Prototype Material Used for Grease Retention Shrouds

    Science.gov (United States)

    Zakrajsek, Andrew J.; Valco, Daniel J.; Street, Kenneth W., Jr.

    2010-01-01

    Effects of hydrocarbon-based greases on specific rapid prototype (RP) materials used to fabricate grease retention shrouds (GRS) were explored in this study. Grease retention shrouds are being considered as a way to maintain adequate grease lubrication at the gear mesh in a prototype research transmission system. Due to their design and manufacturing flexibility, rapid prototype materials were chosen for the grease retention shrouds. In order to gain a better understanding of the short and long term effects grease pose on RP materials, research was conducted on the interaction of hydrocarbon-based grease with RP materials. The materials used in this study were durable polyamide (nylon), acrylonitrile butadiene styrene (ABS), and WaterClear 10120. Testing was conducted using Mobilgrease 28 and Syn-Tech 3913G grease (gear coupling grease). These greases were selected due to their regular use with mechanical components. To investigate the effect that grease has on RP materials, the following methods were used to obtain qualitative and quantitative data: Fourier transform infrared spectroscopy (FT-IR), interference profilometer measurements, digital camera imaging, physical shape measurement, and visual observations. To record the changes in the RP materials due to contact with the grease, data was taken before and after the grease application. Results showed that the WaterClear 10120 RP material provided the best resistance to grease penetration as compared to nylon and ABS RP materials. The manufacturing process, and thus resulting surface conditions of the RP material, played a key role in the grease penetration properties and resilience of these materials.

  14. Rapid Cost Assessment of Space Mission Concepts Through Application of Complexity-Based Cost Indices

    Science.gov (United States)

    Peterson, Craig E.; Cutts, James; Balint, Tibor; Hall, James B.

    2008-01-01

    This slide presentation reviews the development of a rapid cost assessment models for evaluation of exploration missions through the application of complexity based cost indices. In Fall of 2004, NASA began developing 13 documents, known as "strategic roadmaps," intended to outline a strategy for space exploration over the next 30 years. The Third Strategic Roadmap, The Strategic Roadmap for Solar System Exploration, focused on strategy for robotic exploration of the Solar System. Development of the Strategic Roadmap for Solar System Exploration led to the investigation of a large variety of missions. However, the necessity of planning around scientific inquiry and budgetary constraints made it necessary for the roadmap development team to evaluate potential missions not only for scientific return but also cost. Performing detailed cost studies for each of the large number of missions was impractical given the time constraints involved and lack of detailed mission studies; so a method of rapid cost assessment was developed by us to allow preliminary analysis. It has been noted that there is a strong correlation between complexity and cost and schedule of planetary missions. While these correlations were made after missions had been built and flown (successfully or otherwise), it seemed likely that a similar approach could provide at least some relative cost ranking. Cost estimation relationships (CERs) have been developed based on subsystem design choices. These CERs required more detailed information than available, forcing the team to adopt a more high level approach. Costing by analogy has been developed for small satellites, however, planetary exploration missions provide such varying spacecraft requirements that there is a lack of adequately comparable missions that can be used for analogy.

  15. COMPANY VALUATION METHODS BASED ON PATRIMONY

    Directory of Open Access Journals (Sweden)

    SUCIU GHEORGHE

    2013-02-01

    Full Text Available The methods used for the company valuation can be divided into 3 main groups: methods based on patrimony,methods based on financial performance, methods based both on patrimony and on performance. The companyvaluation methods based on patrimony are implemented taking into account the balance sheet or the financialstatement. The financial statement refers to that type of balance in which the assets are arranged according to liquidity,and the liabilities according to their financial maturity date. The patrimonial methods are based on the principle thatthe value of the company equals that of the patrimony it owns. From a legal point of view, the patrimony refers to allthe rights and obligations of a company. The valuation of companies based on their financial performance can be donein 3 ways: the return value, the yield value, the present value of the cash flows. The mixed methods depend both onpatrimony and on financial performance or can make use of other methods.

  16. A Method for Rapid Measurement of Contrast Sensitivity on Mobile Touch-Screens

    Science.gov (United States)

    Mulligan, Jeffrey B.

    2016-01-01

    Touch-screen displays in cell phones and tablet computers are now pervasive, making them an attractive option for vision testing outside of the laboratory or clinic. Here we de- scribe a novel method in which subjects use a finger swipe to indicate the transition from visible to invisible on a grating which is swept in both contrast and frequency. Because a single image can be swiped in about a second, it is practical to use a series of images to zoom in on particular ranges of contrast or frequency, both to increase the accuracy of the measurements and to obtain an estimate of the reliability of the subject. Sensitivities to chromatic and spatio-temporal modulations are easily measured using the same method. A proto- type has been developed for Apple Computer's iPad/iPod/iPhone family of devices, implemented using an open-source scripting environment known as QuIP (QUick Image Processing, http://hsi.arc.nasa.gov/groups/scanpath/research.php). Preliminary data show good agreement with estimates obtained from traditional psychophysical methods as well as newer rapid estimation techniques. Issues relating to device calibration are also discussed.

  17. Development of a rapid HRM genotyping method for detection of dog-derived Giardia lamblia.

    Science.gov (United States)

    Tan, Liping; Yu, Xingang; Abdullahi, Auwalu Yusuf; Wu, Sheng; Zheng, Guochao; Hu, Wei; Song, Meiran; Wang, Zhen; Jiang, Biao; Li, Guoqing

    2015-11-01

    Giardia lamblia is a zoonotic flagellate protozoan in the intestine of human and many mammals including dogs. To assess a threat of dog-derived G. lamblia to humans, the common dog-derived G. lamblia assemblages A, C, and D were genotyped by high-resolution melting (HRM) technology. According to β-giardin gene sequence, the qPCR-HRM primers BG5 and BG7 were designed. A series of experiments on the stability, sensitivity, and accuracy of the HRM method were also tested. Results showed that the primers BG5 and BG7 could distinguish among three assemblages A, C, and D, which Tm value differences were about 1 °C to each other. The melting curves of intra-assay reproducibility were almost coincided, and those of inter-assay reproducibility were much the same shape. The lowest detection concentration was about 5 × 10(-6)-ng/μL sample. The genotyping results from 21 G. lamblia samples by the HRM method were in complete accordance with sequencing results. It is concluded that the HRM genotyping method is rapid, stable, specific, highly sensitive, and suitable for clinical detection and molecular epidemiological survey of dog-derived G. lamblia.

  18. Rapid, high-temperature, field test method for evaluation of geothermal calcium carbonate scale inhibitors

    Energy Technology Data Exchange (ETDEWEB)

    Asperger, R.G.

    1986-09-01

    A new test method is described that allows the rapid field testing of calcium carbonate scale inhibitors at 500/sup 0/F (260/sup 0/C). The method evolved from use of a full-flow test loop on a well with a mass flow rate of about 1 x 10/sup 6/ lbm/hr (126 kg/s). It is a simple, effective way to evaluate the effectiveness of inhibitors under field conditions. Five commercial formulations were chosen for field evaluation on the basis of nonflowing, laboratory screening tests at 500/sup 0/F (260/sup 0/C). Four of these formulations from different suppliers controlled calcium carbonate scale deposition as measured by the test method. Two of these could dislodge recently deposited scale that had not age-hardened. Performance-profile diagrams, which were measured for these four effective inhibitors, show the concentration interrelationship between brine calcium and inhibitor concentrations at which the formulations will and will not stop scale formation in the test apparatus. With these diagrams, one formulation was chosen for testing on the full-flow brine line. The composition was tested for 6 weeks and showed a dramatic decrease in the scaling occurring at the flow-control valve. This scaling was about to force a shutdown of a major, long-term flow test being done for reservoir economic evaluations. The inhibitor stopped the scaling, and the test was performed without interruption.

  19. Rapid Method for the Determination of the Stable Oxygen Isotope Ratio of Water in Alcoholic Beverages.

    Science.gov (United States)

    Wang, Daobing; Zhong, Qiding; Li, Guohui; Huang, Zhanbin

    2015-10-28

    This paper demonstrates the first successful application of an online pyrolysis technique for the direct determination of oxygen isotope ratios (δ(18)O) of water in alcoholic beverages. Similar water concentrations in each sample were achieved by adjustment with absolute ethyl alcohol, and then a fixed GC split ratio can be used. All of the organic ingredients were successfully separated from the analyte on a CP-PoraBond Q column and subsequently vented out, whereas water molecules were transferred into the reaction furnace and converted to CO. With the system presented, 15-30 μL of raw sample was diluted and can be analyzed repeatedly; the analytical precision was better than 0.4‰ (n = 5) in all cases, and more than 50 injections can be made per day. No apparent memory effect was observed even if water samples were injected using the same syringe; a strong correlation (R(2) = 0.9998) was found between the water δ(18)O of measured sample and that of working standards. There was no significant difference (p > 0.05) between the mean δ(18)O value and that obtained by the traditional method (CO2-water equilibration/isotope ratio mass spectrometry) and the newly developed method in this study. The advantages of this new method are its rapidity and straightforwardness, and less test portion is required.

  20. Upconversion nanoparticles based FRET aptasensor for rapid and ultrasenstive bacteria detection.

    Science.gov (United States)

    Jin, Birui; Wang, Shurui; Lin, Min; Jin, Ying; Zhang, Shujing; Cui, Xingye; Gong, Yan; Li, Ang; Xu, Feng; Lu, Tian Jian

    2017-04-15

    Pathogenic bacteria cause serious harm to human health, which calls for the development of advanced detection methods. Herein, we developed a novel detection platform based on fluorescence resonance energy transfer (FRET) for rapid, ultrasensitive and specific bacteria detection, where gold nanoparticles (AuNPs, acceptor) were conjugated with aptamers while upconversion nanoparticles (UCNPs, donor) were functionalized with corresponding complementary DNA (cDNA). The spectral overlap between UCNPs fluorescence emission and AuNPs absorption enables the occurrence of FRET when hybridizing the targeted aptamer and cDNA, causing upconversion fluorescence quenching. In the presence of target bacteria, the aptamers preferentially bind to bacteria forming a three-dimensional structure and thereby dissociate UCNPs-cDNA from AuNPs-aptamers, resulting in the recovery of upconversion fluorescence. Using the UCNPs based FRET aptasensor, we successfully detected Escherichia coli ATCC 8739 (as a model analyte) with a detection range of 5-106cfu/mL and detection limit of 3cfu/mL. The aptasensor was further used to detect E. coli in real food and water samples (e.g., tap/pond water, milk) within 20min. The novel UCNPs based FRET aptasensor could be used to detect a broad range of targets from whole cells to metal ions by using different aptamer sequences, holding great potential in environmental monitoring, medical diagnostics and food safety analysis. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Based on Penalty Function Method

    Directory of Open Access Journals (Sweden)

    Ishaq Baba

    2015-01-01

    Full Text Available The dual response surface for simultaneously optimizing the mean and variance models as separate functions suffers some deficiencies in handling the tradeoffs between bias and variance components of mean squared error (MSE. In this paper, the accuracy of the predicted response is given a serious attention in the determination of the optimum setting conditions. We consider four different objective functions for the dual response surface optimization approach. The essence of the proposed method is to reduce the influence of variance of the predicted response by minimizing the variability relative to the quality characteristics of interest and at the same time achieving the specific target output. The basic idea is to convert the constraint optimization function into an unconstraint problem by adding the constraint to the original objective function. Numerical examples and simulations study are carried out to compare performance of the proposed method with some existing procedures. Numerical results show that the performance of the proposed method is encouraging and has exhibited clear improvement over the existing approaches.

  2. Evaluation of X-ray fluorescence spectroscopy as a method for the rapid and direct determination of sodium in cheese.

    Science.gov (United States)

    Stankey, J A; Akbulut, C; Romero, J E; Govindasamy-Lucey, S

    2015-08-01

    Cheese manufacturers indirectly determine Na in cheese by analysis of Cl using the Volhard method, assuming that all Cl came from NaCl. This method overestimates the actual Na content in cheeses when Na replacers (e.g., KCl) are used. A direct and rapid method for Na detection is needed. X-ray fluorescence spectroscopy (XRF), a mineral analysis technique used in the mining industry, was investigated as an alternative method of Na detection in cheese. An XRF method for the detection of Na in cheese was developed and compared with inductively coupled plasma optical emission spectroscopy (ICP-OES; the reference method for Na in cheese) and Cl analyzer. Sodium quantification was performed by multi-point calibration with cheese standards spiked with NaCl ranging from 0 to 4% Na (wt/wt). The Na concentration of each of the cheese standards (discs: 30mm×7mm) was quantified by the 3 methods. A single laboratory method validation was performed; linearity, precision, limit of detection, and limit of quantification were determined. An additional calibration graph was created using cheese standards made from natural or process cheeses manufactured with different ratios of Na:K. Both Na and K calibration curves were linear for the cheese standards. Sodium was quantified in a variety of commercial cheese samples. The Na data obtained by XRF were in agreement with those from ICP-OES and Cl analyzer for most commercial natural cheeses. The XRF method did not accurately determine Na concentration for several process cheese samples, compared with ICP-OES, likely due to the use of unknown types of Na-based emulsifying salts (ES). When a calibration curve was created for process cheese with the specific types of ES used for this cheese, Na content was successfully predicted in the samples. For natural cheeses, the limit of detection and limit of quantification for Na that can be determined with an acceptable level of repeatability, precision, and trueness was 82 and 246mg/100g of

  3. Validation of a user-friendly and rapid method for quantifying iodine content of salt.

    Science.gov (United States)

    Rohner, Fabian; Garrett, Greg S; Laillou, Arnaud; Frey, Simone K; Mothes, Ralf; Schweigert, Florian J; Locatelli-Rossi, Lorenzo

    2012-12-01

    Despite considerable progress made in the past decade through salt iodization programs, over 2 billion people worldwide still have inadequate iodine intake, with devastating consequences for brain development and intellectual capacity. To optimize these programs with regard to salt iodine content, careful monitoring of salt iodine content is essential, but few methods are available to quantitatively measure iodine concentration in a simple, fast, and safe way. We have validated a newly developed device that quantitatively measures the content of potassium iodate in salt in a simple, safe, and rapid way. The linearity, determination and detection limit, and inter- and intra-assay variability of this colorimetric method were assessed and the method was compared with iodometric titration, using salt samples from several countries. Linearity of analysis ranged from 5 to 75 mg/kg iodine, with 1 mg/kg being the determination limit; the intra- and interassay imprecision was 0.9%, 0.5%, and 0.7% and 1.5%, 1.7%, and 2.5% for salt samples with iodine contents of 17, 30, and 55 mg/kg, respectively; the interoperator imprecision for the same samples was 1.2%, 4.9%, and 4.7%, respectively. Comparison with the iodometric method showed high agreement between the methods (R2 = 0.978; limits of agreement, -10.5 to 10.0 mg/kg). The device offers a field- and user-friendly solution to quantifying potassium iodate salt content reliably. For countries that use potassium iodide in salt iodization programs, further validation is required.

  4. A method for rapid measurement of intrarenal and other tissue pressures.

    Science.gov (United States)

    SWANN, H G; MONTGOMERY, A V; DAVIS, J C; MICKLE, E R

    1950-12-01

    A rapid method for measuring tissue pressures has been designed. A pressure of 250 mm. Hg is imposed on a manometer. Then the system is allowed to discharge into a needle cannula inserted in the tissue. The manometer forces out fluid (about 10 c.mm.) until the pressure within it is the same as that within the tissue. Records of the pressure changes are made. Each observation takes about a minute. The method gives results that are closely comparable with other reports of tissue pressures. With this method, the pressure in the following organs of dogs was found to be: kidney, 26 mm. Hg, cerebral cortex, 0 to 5 mm., muscle, 1 to 10 mm., spleen, S to 16 mm., subcutaneous tissue, 0 to 3 mm., and liver -2 to 14 mm. The reliability of the method was tested on the kidneys of decerebrate dogs. Measurements were found to be the same within narrow limits over a period of an hour; they were the same when taken simultaneously in different regions of the same kidney or in opposite kidneys. They were independent of the volume of fluid forced into the tissue. Similar pressures were observed with 1 or 5 or 10 holes bored in the shaft of the cannulating needle. The intrarenal pressure was also measured by inserting a needle cannula into the tissue and then allowing the pressure to reach equilibrium passively with a manometer. This method gave similar results. The intrarenal pressure has now found to be the same when measured by three different technics.

  5. Rapid, sensitive and cost effective method for isolation of viral DNA from feacal samples of dogs

    Directory of Open Access Journals (Sweden)

    Savi.

    2010-06-01

    Full Text Available A simple method for viral DNA extraction using chelex resin was developed. The method used was eco-friendly and cost effective compared to other methods such as phenol chloroform method which use health hazardous organic reagents. Further, a polymerase chain reaction (PCR based detection of canine parvovirus (CPV using primers from conserved region of VP2 gene was developed. To increase the sensitivity and specificity of reaction, nested PCR was designed. PCR reaction was optimized to amplify 747bp product of VP2 gene. The assay can be completed in few hours and doesn’t need hazardous chemicals. Thus, the sample preparation using chelating resin along with nested PCR seems to be a sensitive, specific and practical method for the detection of CPV in diarrhoeal feacal samples. [Vet. World 2010; 3(3.000: 105-106

  6. An interactive segmentation method based on superpixel

    DEFF Research Database (Denmark)

    Yang, Shu; Zhu, Yaping; Wu, Xiaoyu

    2015-01-01

    This paper proposes an interactive image-segmentation method which is based on superpixel. To achieve fast segmentation, the method is used to establish a Graphcut model using superpixels as nodes, and a new energy function is proposed. Experimental results demonstrate that the authors' method has...... excellent performance in terms of segmentation accuracy and computation efficiency compared with other segmentation algorithm based on pixels....

  7. A rapid method for the sequential separation of polonium, plutonium, americium and uranium in drinking water.

    Science.gov (United States)

    Lemons, B; Khaing, H; Ward, A; Thakur, P

    2018-02-06

    A new sequential separation method for the determination of polonium and actinides (Pu, Am and U) in drinking water samples has been developed that can be used for emergency response or routine water analyses. For the first time, the application of TEVA chromatography column in the sequential separation of polonium and plutonium has been studied. This method utilizes a rapid Fe +3 co-precipitation step to remove matrix interferences, followed by plutonium oxidation state adjustment to Pu 4+ and an incubation period of ~ 1 h at 50-60 °C to allow Po 2+ to oxidize to Po 4+ . The polonium and plutonium were then separated on a TEVA column, while separation of americium from uranium was performed on a TRU column. After separation, polonium was micro-precipitated with copper sulfide (CuS), while actinides were micro co-precipitated using neodymium fluoride (NdF 3 ) for counting by the alpha spectrometry. The method is simple, robust and can be performed quickly with excellent removal of interferences, high chemical recovery and very good alpha peak resolution. The efficiency and reliability of the procedures were tested by using spiked samples. The effect of several transition metals (Cu 2+ , Pb 2+ , Fe 3+ , Fe 2+ , and Ni 2+ ) on the performance of this method were also assessed to evaluate the potential matrix effects. Studies indicate that presence of up to 25 mg of these cations in the samples had no adverse effect on the recovery or the resolution of polonium alpha peaks. Copyright © 2018 Elsevier Ltd. All rights reserved.

  8. Veterinary drug residues in meat: Concerns and rapid methods for detection.

    Science.gov (United States)

    Reig, Milagro; Toldrá, Fidel

    2008-01-01

    The use of substances having hormonal or thyreostatic action as well as β-agonists is banned in the European Union. However, sometimes forbidden drugs may be added to feeds for illegal administration to farm animals for promoting increased muscle development or increased water retention and thus obtain an economical benefit. The result is a fraudulent overweight of meat but, what is worse, residues of these substances may remain in meat and may pose a real threat to the consumer either through exposure to the residues, transfer of antibiotic resistance or allergy risk. This has exerted a great concern among European consumers. The control of the absence of these forbidden substances in animal foods and feeds is regulated in the European Union by Directive96/23/EC on measures to monitor certain substances and residues in live animals and animal products. Analytical methodology, including criteria for identification and confirmation, for the monitoring of compliance was also given in Decisions 93/256/EEC and 93/257/EEC. More recently, Decision 2002/657/EC provided rules for the analytical methods to be used in testing of official samples. A crucial step is the screening of veterinary drug residues in live animals, feeds and animal products in view of the remarkable number of samples and large variety of residues to be analysed. In recent years, different rapid methods having easy performance, high sensitivity and high throughput have been proposed and are being extensively used. These methods as well as other new methods are reviewed in this manuscript.

  9. Rapid restriction enzyme-free cloning of PCR products: a high-throughput method applicable for library construction.

    Directory of Open Access Journals (Sweden)

    Vijay K Chaudhary

    Full Text Available Herein, we describe a novel cloning strategy for PCR-amplified DNA which employs the type IIs restriction endonuclease BsaI to create a linearized vector with four base-long 5'-overhangs, and T4 DNA polymerase treatment of the insert in presence of a single dNTP to create vector-compatible four base-long overhangs. Notably, the insert preparation does not require any restriction enzyme treatment. The BsaI sites in the vector are oriented in such a manner that upon digestion with BsaI, a stuffer sequence along with both BsaI recognition sequences is removed. The sequence of the four base-long overhangs produced by BsaI cleavage were designed to be non-palindromic, non-compatible to each other. Therefore, only ligation of an insert carrying compatible ends allows directional cloning of the insert to the vector to generate a recombinant without recreating the BsaI sites. We also developed rapid protocols for insert preparation and cloning, by which the entire process from PCR to transformation can be completed in 6-8 h and DNA fragments ranging in size from 200 to 2200 bp can be cloned with equal efficiencies. One protocol uses a single tube for insert preparation if amplification is performed using polymerases with low 3'-exonuclease activity. The other protocol is compatible with any thermostable polymerase, including those with high 3'-exonuclease activity, and does not significantly increase the time required for cloning. The suitability of this method for high-throughput cloning was demonstrated by cloning batches of 24 PCR products with nearly 100% efficiency. The cloning strategy is also suitable for high efficiency cloning and was used to construct large libraries comprising more than 108 clones/µg vector. Additionally, based on this strategy, a variety of vectors were constructed for the expression of proteins in E. coli, enabling large number of different clones to be rapidly generated.

  10. A rapid method to authenticate vegetable oils through surface-enhanced Raman scattering

    Science.gov (United States)

    Lv, Ming Yang; Zhang, Xin; Ren, Hai Rui; Liu, Luo; Zhao, Yong Mei; Wang, Zheng; Wu, Zheng Long; Liu, Li Min; Xu, Hai Jun

    2016-03-01

    Vegetable oils are essential in our daily diet. Among various vegetable oils, the major difference lies in the composition of fatty acids, including unsaturated fatty acids (USFA) and saturated fatty acids (SFA). USFA include oleic acid (OA), linoleic acid (LA), and α-linolenic acid (ALA), while SFA are mainly palmitic acid (PA). In this study, the most typical and abundant USFA present with PA in vegetable oils were quantified. More importantly, certain proportional relationships between the integrated intensities of peaks centered at 1656 cm-1 (S1656) in the surface-enhanced Raman scattering spectra of different USFA were confirmed. Therefore, the LA or ALA content could be converted into an equivalent virtual OA content enabling the characterization of the USFA content in vegetable oils using the equivalent total OA content. In combination with the S1656 of pure OA and using peanut, sesame, and soybean oils as examples, the ranges of S1656 corresponding to the National Standards of China were established to allow the rapid authentication of vegetable oils. Gas chromatograph-mass spectrometer analyses verified the accuracy of the method, with relative errors of less than 5%. Moreover, this method can be extended to other detection fields, such as diseases.

  11. New multiplex PCR methods for rapid screening of genetically modified organisms in foods.

    Science.gov (United States)

    Datukishvili, Nelly; Kutateladze, Tamara; Gabriadze, Inga; Bitskinashvili, Kakha; Vishnepolsky, Boris

    2015-01-01

    We present novel multiplex PCR methods for rapid and reliable screening of genetically modified organisms (GMOs). New designed PCR primers targeting four frequently used GMO specific sequences permitted identification of new DNA markers, in particular 141 bp fragment of cauliflower mosaic virus (CaMV) 35S promoter, 224 bp fragment of Agrobacterium tumefaciens nopaline synthase (NOS) terminator, 256 bp fragment of 5-enolppyruvylshikimate-phosphate synthase (epsps) gene and 258 bp fragment of Cry1Ab delta-endotoxin (cry1Ab) gene for GMO screening. The certified reference materials containing Roundup Ready soybean (RRS) and maize MON 810 were applied for the development and optimization of uniplex and multiplex PCR systems. Evaluation of amplification products by agarose gel electrophoresis using negative and positive controls confirmed high specificity and sensitivity at 0.1% GMO for both RRS and MON 810. The fourplex PCR was developed and optimized that allows simultaneous detection of three common transgenic elements, such as: CaMV 35S promoter, NOS terminator, epsps gene together with soybean-specific lectin gene. The triplex PCR developed enables simultaneous identification of transgenic elements, such as: 35S promoter and cry1Ab gene together with maize zein gene. The analysis of different processed foods demonstrated that multiplex PCR methods developed in this study are useful for accurate and fast screening of GM food products.

  12. A simple and rapid method for optical visualization and quantification of bacteria on textiles

    Science.gov (United States)

    Stiefel, Philipp; Schneider, Jana; Amberg, Caroline; Maniura-Weber, Katharina; Ren, Qun

    2016-01-01

    To prevent bacterial contamination on textiles and the associated undesired effects different biocidal coatings have been investigated and applied. However, due to health and environmental concerns anti-adhesive coatings preventing the binding of bacteria would be favored. To develop such anti-adhesive coatings simple assays for reliable and fast screening are beneficial. Here an easy-to-handle, robust and rapid assay to assess bacteria on textiles utilizing a tetrazolium salt was reported. The assay allowed direct eye visualization of the color change of the textiles containing bacteria, facilitating fast screening. Quantification of the adhered bacteria could be done by generating standard curves which correlate the staining intensity to cell numbers. An additional advantage of the described assay is that with the same detection method anti-adhesive and biocidal effects can be investigated. The method was applied to different coatings, using Pseudomonas aeruginosa and Staphylococcus aureus as model organisms. The detection limit was found to be between 2.5 * 106 and 9.4 * 108 for P. aeruginosa and between 1 * 106 and 3.3 * 108 for S. aureus. The anti-adhesive coating PLUMA was demonstrated to reduce bacterial adhesion without killing them, whereas the biocidal coating TH22-27 caused a clear reduction in the number of viable cells. PMID:28004762

  13. Development of a Rapid and Simple Method to Remove Polyphenols from Plant Extracts

    Directory of Open Access Journals (Sweden)

    Imali Ranatunge

    2017-01-01

    Full Text Available Polyphenols are secondary metabolites of plants, which are responsible for prevention of many diseases. Polyvinylpolypyrrolidone (PVPP has a high affinity towards polyphenols. This method involves the use of PVPP column to remove polyphenols under centrifugal force. Standards of gallic acid, epigallocatechin gallate, vanillin, and tea extracts (Camellia sinensis were used in this study. PVPP powder was packed in a syringe with different quantities. The test samples were layered over the PVPP column and subjected to centrifugation. Supernatant was tested for the total phenol content. The presence of phenolic compounds and caffeine was screened by HPLC and measuring the absorbance at 280. The antioxidant capacity of standards and tea extracts was compared with the polyphenol removed fractions using DPPH scavenging assay. No polyphenols were found in polyphenolic standards or tea extracts after PVPP treatment. The method described in the present study to remove polyphenols is simple, inexpensive, rapid, and efficient and can be employed to investigate the contribution of polyphenols present in natural products to their biological activity.

  14. A Rapid and Low-Cost Nonlithographic Method to Fabricate Biomedical Microdevices for Blood Flow Analysis

    Directory of Open Access Journals (Sweden)

    Elmano Pinto

    2014-12-01

    Full Text Available Microfluidic devices are electrical/mechanical systems that offer the ability to work with minimal sample volumes, short reactions times, and have the possibility to perform massive parallel operations. An important application of microfluidics is blood rheology in microdevices, which has played a key role in recent developments of lab-on-chip devices for blood sampling and analysis. The most popular and traditional method to fabricate these types of devices is the polydimethylsiloxane (PDMS soft lithography technique, which requires molds, usually produced by photolithography. Although the research results are extremely encouraging, the high costs and time involved in the production of molds by photolithography is currently slowing down the development cycle of these types of devices. Here we present a simple, rapid, and low-cost nonlithographic technique to create microfluidic systems for biomedical applications. The results demonstrate the ability of the proposed method to perform cell free layer (CFL measurements and the formation of microbubbles in continuous blood flow.

  15. New multiplex PCR methods for rapid screening of genetically modified organisms in foods

    Directory of Open Access Journals (Sweden)

    Nelly eDatukishvili

    2015-07-01

    Full Text Available We present novel multiplex PCR methods for rapid and reliable screening of genetically modified organisms (GMOs. New designed PCR primers targeting four frequently used GMO specific sequences permitted identification of new DNA markers, in particular 141 bp fragment of cauliflower mosaic virus (CaMV 35S promoter, 224 bp fragment of Agrobacterium tumefaciens nopaline synthase (NOS terminator, 256 bp fragment of 5-enolppyruvylshikimate-phosphate synthase (epsps gene and 258 bp fragment of Cry1Ab delta-endotoxin (cry1Ab gene for GMO screening. The certified reference materials containing Roundup Ready soybean (RRS and maize MON 810 were applied for the development and optimization of uniplex and multiplex PCR systems. Evaluation of amplification products by agarose gel electrophoresis using negative and positive controls confirmed high specificity and sensitivity at 0.1% GMO for both RRS and MON 810. The fourplex PCR was developed and optimized that allows simultaneous detection of three common transgenic elements, such as: CaMV 35S promoter, NOS terminator, epsps gene together with soybean-specific lectin gene. The triplex PCR developed enables simultaneous identification of transgenic elements, such as: 35S promoter and cry1Ab gene together with maize zein gene. The analysis of different processed foods demonstrated that multiplex PCR methods developed in this study are useful for accurate and fast screening of GM food products.

  16. Regional distribution of methionine adenosyltransferase in rat brain as measured by a rapid radiochemical method

    Energy Technology Data Exchange (ETDEWEB)

    Hiemke, C.; Ghraf, R.

    1981-09-01

    The distribution of methionine adenosyltransferase (MAT) in the CNS of the rat was studied by use of a rapid, sensitive and specific radiochemical method. The S-adenosyl-(methyl-/sup 14/C)L-methionine ((/sup 14/C)SAM) generated by adenosyl transfer from ATP to (methyl-/sup 14/C)L-methionine is quantitated by use of a SAM-consuming transmethylation reaction. Catechol O-methyltransferase (COMT), prepared from rat liver, transfers the methyl-/sup 14/C group of SAM to 3,4-dihydroxybenzoic acid. The /sup 14/C-labelled methylation products, vanillic acid and isovanillic acid, are separated from unreacted methionine by solvent extraction and quantitated by liquid scintillation counting. Compared to other methods of MAT determination, which include separation of generated SAM from methionine by ion-exchange chromatography, the assay described exhibited the same high degree of specificity and sensitivity but proved to be less time consuming. MAT activity was found to be uniformly distributed between various brain regions and the pituitary gland of adult male rats. In the pineal gland the enzyme activity is about tenfold higher.

  17. Nano and Microparticulate Chitosan Based System for Formulation of Carvedilol Rapid Melt Tablet

    Directory of Open Access Journals (Sweden)

    Ravindra Patil

    2015-06-01

    Full Text Available Purpose: In the present study rapid melt tablets (RMT’s of carvedilol were prepared by using ionotropic-gelated chitosan nanoparticles using a spray-drying method. Carvedilol is beta-adrenergic antagonist and its oral bioavailability is about 25-35% because of first pass metabolism. Methods: The spray-dried microparticles were formulated into RMT’s using a wet granulation process. The Formulation and optimization of carvedilol loaded RMTs using nano and microparticulate chitosan based system (NMCS was done by using 32 factorial designs. Results: Drug entrapment efficiency of about 64.9 % (w/w and loading capacity of 14.44% (w/w were achieved for the microparticles, which were ranged from 1 μm to 4 μm in diameter. Results of disintegration tests showed that the formulated RMTs could be completely dissolved within 40 seconds. Dissolution studies suggested that Carvedilol is released more slowly from tablets made using the microencapsulation process compared with tablets containing Carvedilol that is free or in the form of nanoparticles. Conclusion: Results shown that the development of new RMTs designed with crosslinked microparticle might be a rational way to overcome the unwanted taste of conventional RMTs and the side effects related to Carvedilol intrinsic characteristics. The development of Carvedilol NMCS using ludiflash as RMTs could be used as a promising approach for improving the solubility and oral bioavailability of water insoluble drug.

  18. Rapid classification of heavy metal-exposed freshwater bacteria by infrared spectroscopy coupled with chemometrics using supervised method

    Science.gov (United States)

    Gurbanov, Rafig; Gozen, Ayse Gul; Severcan, Feride

    2018-01-01

    Rapid, cost-effective, sensitive and accurate methodologies to classify bacteria are still in the process of development. The major drawbacks of standard microbiological, molecular and immunological techniques call for the possible usage of infrared (IR) spectroscopy based supervised chemometric techniques. Previous applications of IR based chemometric methods have demonstrated outstanding findings in the classification of bacteria. Therefore, we have exploited an IR spectroscopy based chemometrics using supervised method namely Soft Independent Modeling of Class Analogy (SIMCA) technique for the first time to classify heavy metal-exposed bacteria to be used in the selection of suitable bacteria to evaluate their potential for environmental cleanup applications. Herein, we present the powerful differentiation and classification of laboratory strains (Escherichia coli and Staphylococcus aureus) and environmental isolates (Gordonia sp. and Microbacterium oxydans) of bacteria exposed to growth inhibitory concentrations of silver (Ag), cadmium (Cd) and lead (Pb). Our results demonstrated that SIMCA was able to differentiate all heavy metal-exposed and control groups from each other with 95% confidence level. Correct identification of randomly chosen test samples in their corresponding groups and high model distances between the classes were also achieved. We report, for the first time, the success of IR spectroscopy coupled with supervised chemometric technique SIMCA in classification of different bacteria under a given treatment.

  19. Profiling method for a rapid and efficient screening of transgenic plants

    African Journals Online (AJOL)

    user

    2012-06-28

    Jun 28, 2012 ... Metabolomics-based approaches are methods of choice for studying changes in fruit composition induced by environmental or genetic modulation of biochemical pathways in the fruit. Owing to enzyme redundancy and high plasticity of the metabolic network, transgenic alteration of the activity of the.

  20. A Rapid Empirical Method for Estimating the Gross Takeoff Weight of a High Speed Civil Transport

    Science.gov (United States)

    Mack, Robert J.

    1999-01-01

    During the cruise segment of the flight mission, aircraft flying at supersonic speeds generate sonic booms that are usually maximum at the beginning of cruise. The pressure signature with the shocks causing these perceived booms can be predicted if the aircraft's geometry, Mach number, altitude, angle of attack, and cruise weight are known. Most methods for estimating aircraft weight, especially beginning-cruise weight, are empirical and based on least- square-fit equations that best represent a body of component weight data. The empirical method discussed in this report used simplified weight equations based on a study of performance and weight data from conceptual and real transport aircraft. Like other weight-estimation methods, weights were determined at several points in the mission. While these additional weights were found to be useful, it is the determination of beginning-cruise weight that is most important for the prediction of the aircraft's sonic-boom characteristics.

  1. Rapid PCR-based assay for Sclerotinia sclerotiorum detection on soybean seeds

    Directory of Open Access Journals (Sweden)

    Edilaine Mauricia Gelinski Grabicoski

    2015-02-01

    Full Text Available Caused by Sclerotinia sclerotiorum, white mold is an important seed-transmitted disease of soybean (Glycine max. Incubation-based methods available for the detection and quantification of seed-borne inoculum such as the blotter test, paper roll and Neon-S assay are time-consuming, laborious, and not always sensitive. In this study, we developed and evaluated a molecular assay for the detection of S. sclerotiorum in soybean seeds using a species-specific PCR (polymerase chain reaction primer set and seed soaking (without DNA extraction for up to 72 h. The PCR products were amplified in all the samples infected with the pathogen, but not in the other samples of plant material or the other seed-borne fungi DNA. The minimum amount of DNA detected was 10 pg, or one artificially infested seed in a 400-seed sample (0.25 % fungal incidence and one naturally infected seed in a 300-seed sample (0.33 % incidence. The PCR-based assay was rapid (< 9 h, did not require DNA extraction and was very sensitive.

  2. A rapid automatic analyzer and its methodology for effective bentonite content based on image recognition technology

    Directory of Open Access Journals (Sweden)

    Wei Long

    2016-09-01

    Full Text Available Fast and accurate determination of effective bentonite content in used clay bonded sand is very important for selecting the correct mixing ratio and mixing process to obtain high-performance molding sand. Currently, the effective bentonite content is determined by testing the ethylene blue absorbed in used clay bonded sand, which is usually a manual operation with some disadvantages including complicated process, long testing time and low accuracy. A rapid automatic analyzer of the effective bentonite content in used clay bonded sand was developed based on image recognition technology. The instrument consists of auto stirring, auto liquid removal, auto titration, step-rotation and image acquisition components, and processor. The principle of the image recognition method is first to decompose the color images into three-channel gray images based on the photosensitive degree difference of the light blue and dark blue in the three channels of red, green and blue, then to make the gray values subtraction calculation and gray level transformation of the gray images, and finally, to extract the outer circle light blue halo and the inner circle blue spot and calculate their area ratio. The titration process can be judged to reach the end-point while the area ratio is higher than the setting value.

  3. Validation of a rapid lateral flow method for the detection of cows' milk in water buffalo, sheep or goat milk.

    Science.gov (United States)

    Galan-Malo, Patricia; Mendiara, Isabel; Razquin, Pedro; Mata, Luis

    2018-01-22

    For many years, the adulteration of milk from sheep, goats or water buffalos with cows' milk has been a widespread practice due to the higher cost of milk from those other species. Because of this, great concern has been shown by many Protected Designation of Origin councils that have to assure the quality and genuineness of the cheese produced by their associates. Therefore, the whole production chain needs analytical tools that allow the control of potential adulteration. Rapid methods to be used in the field are scarce and have not been validated according to international guidelines. The aim of this work has been to validate a rapid test based on lateral flow immunochromatography to detect cows' milk in milk from other species, including buffalo's milk, according to AOAC guidelines. No false-positive result was found after analysing 146 known negative samples from individual animals. The lowest level of adulteration with a Probability of Detection (POD) of 1.00 (confidence interval between 0.94 and 1.00) was found at 0.5% of cows' milk. This level is below the current EU allowed level of cows' milk, set at 1%. Variations in the time of assay, volume of the analysis buffer and different batches of the test were evaluated to detect any effect on the false-positive rate or on the limit of detection of the test. The effects of compositional factors (such as high level of fat, protein and somatic cell counts) were also evaluated. The new rapid test to detect cows' milk in milk from other species is shown to be an adequate tool to control milk quality in routine analysis. This kind of test is very easy to use and it can be performed by untrained staff during milk collection at the farm or upon arrival at dairies.

  4. High resolution melting curve analysis, a rapid and affordable method for mutation analysis in childhood acute myeloid leukemia

    Directory of Open Access Journals (Sweden)

    Yin eLiu

    2014-09-01

    Full Text Available Background: Molecular genetic alterations with prognostic significance have been described in childhood acute myeloid leukemia (AML. The aim of this study was to establish cost-effective techniques to detect mutations of FMS-like tyrosine kinase 3 (FLT3, Nucleophosmin 1 (NPM1, and a partial tandem duplication within the mixed lineage leukemia (MLL-PTD genes in childhood AML. Procedure: Ninety-nine children with newly diagnosed AML were included in this study. We developed a fluoresent dye SYTO-82 based high resolution melting curve (HRM anaylsis to detect FLT3 internal tandem duplication (FLT3-ITD, FLT3 tyrosine kinase domain (FLT3-TKD and NPM1 mutations. MLL-PTD was screened by real-time quantitative PCR. Results: The HRM methodology correlated well with gold standard Sanger sequencing with less cost. Among the 99 patients studied, the FLT3-ITD mutation was associated with significantly worse event free survival (EFS. Patients with the NPM1 mutation had significantly better EFS and overall survival. However, HRM was not sensitive enough for minimal residual disease monitoring. Conclusions: HRM was a rapid and efficient method for screening of FLT3 and NPM1 gene mutations. It was both affordable and accurate, especially in resource underprivileged regions. Our results indicated that HRM could be a useful clinical tool for rapid and cost effective screening of the FLT3 and NPM1 mutations in AML patients.

  5. A rapid method for selecting suitable animal species for studying pathogen interactions with plasma protein ligands in vivo.

    Science.gov (United States)

    Naudin, Clément; Schumski, Ariane; Salo-Ahen, Outi M H; Herwald, Heiko; Smeds, Emanuel

    2017-05-01

    Species tropism constitutes a serious problem for developing relevant animal models of infection. Human pathogens can express virulence factors that show specific selectivity to human proteins, while their affinity for orthologs from other species can vary significantly. Suitable animal species must be used to analyse whether virulence factors are potential targets for drug development. We developed an assay that rapidly predicts applicable animal species for studying virulence factors binding plasma proteins. We used two well-characterized Staphylococcus aureus proteins, SSL7 and Efb, to develop an ELISA-based inhibition assay using plasma from different animal species. The interaction between SSL7 and human C5 and the binding of Efb to human fibrinogen and human C3 was studied. Affinity experiments and Western blot analyses were used to validate the assay. Human, monkey and cat plasma interfered with binding of SSL7 to human C5. Binding of Efb to human fibrinogen was blocked in human, monkey, gerbil and pig plasma, while human, monkey, gerbil, rabbit, cat and guinea pig plasma inhibited the binding of Efb to human C3. These results emphasize the importance of choosing correct animal models, and thus, our approach is a rapid and cost-effective method that can be used to prevent unnecessary animal experiments. © 2017 The Authors. Microbial Biotechnology published by John Wiley & Sons Ltd and Society for Applied Microbiology.

  6. LC-ESI/MS/MS method for rapid screening and confirmation of 44 exogenous anabolic steroids in human urine.

    Science.gov (United States)

    Jeon, Byoung Wook; Yoo, Hye Hyun; Jeong, Eun Sook; Kim, Ho Jun; Jin, Changbae; Kim, Dong Hyun; Lee, Jaeick

    2011-09-01

    A sensitive and rapid method based on liquid chromatography-triple-quadrupole tandem mass spectrometry (LC-MS/MS) with electrospray ionization (ESI) has been developed and validated for the screening and confirmation of 44 exogenous anabolic steroids (29 parent steroids and 15 metabolites) in human urine. The method involves an enzymatic hydrolysis, liquid-liquid extraction, and detection by LC-MS/MS. A triple-quadrupole mass spectrometer was operated in positive ESI mode with selected reaction monitoring (SRM) mode for the screening and product ion scan mode for the confirmation. The protonated molecular ions were used as precursor ions for the SRM analysis and product ion scan. The intraday and interday precisions of the target analytes at concentrations of the minimum required performance levels for the screening were 2-14% and 2-15%, respectively. The limits of detection for the screening and confirmation method were 0.1-10 ng/mL and 0.2-10 ng/mL, respectively, for 44 steroids. This method was successfully applied to analysis of urine samples from suspected anabolic steroid abusers.

  7. Presenting a rapid method for detection of Bacillus cereus, Listeria monocytogenes and Campylobacter jejuni in food samples

    Directory of Open Access Journals (Sweden)

    Ali Razei

    2017-08-01

    Full Text Available Objective(s: Listeria monocytogens, Bacillus cereus and Campylobacter jejuni are three toxin producing bacteria over the world, especially in Iran, and it is essential to find a certain, rapid procedure to identify these microorganisms. In this research, these bacteria were simultaneously detected by multiplex PCR technique in foods. Materials and Methods: The primary approval of bacterial strains was performed by biochemical tests. PCR primers were designed based on the nucleotide sequences of the NHEB/NHEC gene of B. cereus, the hly gene of L. monocytogenes and the C gene of C. jejuni. The specificity of Multiplex PCR method was determined using seven food poisoning bacteria including Salmonella typhi, Shigella dysentery, Yersinia pestis, Staphylococcus aureus, Clostridium perfringens, Clostridium botulinum and Vibrio cholerae. To confirm the reaction, DNA extraction was performed from 30 food samples (milk, and gene amplification was performed by PCR. The length of amplified fragments was 300 bp, 210 bp and 160 bpfor NHEB/NHEC, hly and C genes, respectively. Results: The detection limits of the PCR method were 5, 4 and 3 pg for L. monocytogenes, B. cereus and C. jejuni, respectively. Specifisity test showed that this reaction is spesific to these 3 bacteria. Conclusion: In this study, we  introduced a new multiplex PCR method for simultsnus detection of L. monocytogens, B. cereus and C. jejuni. These results can be used  for detection of other toxin producing bacteria in food.

  8. Method and apparatus using selected superparamagnetic labels for rapid quantification of immunochromatographic tests

    Directory of Open Access Journals (Sweden)

    Mika PA Laitinen

    2009-04-01

    Full Text Available Mika PA Laitinen1, Jari Salmela2, Leona Gilbert1, Risto Kaivola1, Topi Tikkala2, Christian Oker-Blom1, Jukka Pekola3, Matti Vuento11Department of Biological and Environmental Science; 2Department of Physics, University of Jyväskylä, Jyväskylä, Finland; 3Low Temperature Laboratory, Helsinki University of Technology, Helsinki, FinlandAbstract: A rapid method and instrumentation for quantification of immunochromatographic tests (ICT are described. The principle and performance of the method was demonstrated by measuring the levels of human chorionic gonadotropin (hCG present in urine. The test format was a sandwich assay using two distinct monoclonal antibodies directed against hCG. The first anti-hCG antibody was labeled with superparamagnetic particles whereas the second was immobilized as a narrow detection zone on a porous membrane. The human urine sample was mixed with superparamagnetic particles coated with the first anti-hCG antibody, and the mixture was allowed to migrate past the detection zone containing the second anti-hCG antibody. Capillary forces facilitated migration of the immune complexes along the porous membrane. The amount of superparamagnetic particle-labelled monoclonal anti-hCG bound to the detection zone was directly proportional to the amount of hCG present in the sample as detected by measuring magnetization in the detector coil. The method had a practical detection limit of 20 U/l (54 nM of hCG per 5 μl of human urine and a linear range of three decades from 20 U/l to 10 000 U/l. In addition, the analysis was completed within less than 10 minutes. Thus, the test format should be suitable for fast detection and monitoring of a large variety of clinically important parameters and analytes.Keywords: affinity, biosensor, hCG, immunochromatography, magnetization, superparamagnetic

  9. Rapid methods to assess sanitizing efficacy of benzalkonium chloride to Listeria monocytogenes biofilms