  1. Rapid and Convenient Separation of Chitooligosaccharides by Ion-Exchange Chromatography

    Science.gov (United States)

    Wu, Yuxiao; Lu, Wei-Peng; Wang, Jianing; Gao, Yunhua; Guo, Yanchuan

    2017-12-01

    Pervious methods for separation of highly purified chitooligosaccharides was time-consuming and labor-intensive, which limited the large-scale production. This study developed a convenient ion-exchange chromatography using the ÄKTA™ avant 150 chromatographic system. Five fractions were automatically collected under detecting the absorption at 210 nm. The fractions were analyzed by high-performance liquid chromatography. It proved that they primarily comprised chitobiose, chitotriose, chitotetraose, chitopentaose, and chitohexaose, respectively, with chromatographic purities over 90%. The separation process was rapid, convenient and could be monitored on-line, which would be benefit for the mass production of chitooligosaccharides.

  2. Rapid determination of bisphosphonates by ion chromatography with indirect UV detection.

    Science.gov (United States)

    Fernandes, Christian; Leite, Rodrigo S; Lanças, Fernando M

    2007-01-01

    Rapid methods for etidronate, clodronate, pamidronate, and alendronate assays are presented. The methods are based on ion chromatography with indirect UV detection, which avoids the need for chemical derivatization procedures. Each compound is analyzed on an individual basis. There is no need for having separation among these analytes because the aim of the proposed methods is to analyze each compound separately either in bulk material or pharmaceuticals. Phenosphere (150 x 2.0-mm, 5 microm) and Sphereclone (250 x 2.0-mm, 5 microm) anion exchange columns were employed with sodium citrate (20mM) as the mobile phase. The methods are simple, rapid (analysis time of 5 min for etidronate and clodronate and 7 min for alendronate and pamidronate), and demonstrate precision (relative standard deviation was lower than 2.0% in all concentrations), accuracy, and specificity. Calibration curves are linear with r(2) > 0.99 over the concentration range of 50 to 400 microg/mL for etidronate and clodronate, and of 100 to 500 microg/mL for pamidronate and alendronate. Furthermore, they employed silica-based columns, which are cheaper than polymeric columns frequently used in previous reported methods.

  3. [Rapid determination of alkaloids in tobacco using gas chromatography-mass spectrometry with full scan-selected ion monitoring mode].

    Science.gov (United States)

    Wang, Baoxing; Yang, Shihua; Hou, Ying; Zeng, Xiaoying; Wu, Yi; Xu, Guowang

    2008-05-01

    Simultaneous full scan-selected ion monitoring mode (Scan-SIM) is a new improvement method of data acquisition of gas chromatography-mass spectrometry (GC-MS). A method of determing alkaloids in tobacco was established by GC-MS with Scan-SIM. Nicotine, nornicotine, anabasine and anatabine were determined with scan mode, and myosmine, nicotyrine, 2,3'-bipyridyl and cotinine were determined with SIM mode. The average recoveries of alkaloids ranged from 94.8% to 98.8%, and the relative standard deviations were less than 6.0% (n = 5). Therefore, it is a simple, rapid, accurate method. Tobacco samples picked in different years were determined using this method, and the results were satisfactory.

  4. [Rapid screening and identification of 22 allergenic disperse dyes in ecological textiles by high performance liquid chromatography-linear ion trap/orbitrap mass spectrometry].

    Science.gov (United States)

    Niu, Zengyuan; Luo, Xin; Ye, Xiwen; Xiu, Xiaoli; Zhang, Li; Wang, Xin; Chen, Jing

    2015-10-01

    A rapid screening method based on high performance liquid chromatography-linear ion trap/orbitrap high-resolution mass spectrometry (HPLC-LTQ/Orbitrap MS) for 22 disperse dyes in ecological textiles has been established. The target compounds were extracted by pyridine/water (1:1, v/v) by shaking extraction in 90 degrees C water bath. The extracts were then separated by a CAPCELL PAK C18 column (100 mm x 2.0 mm, 5 μm) using gradient elution with acetonitrile-5 mmol/L ammonium acetate containing 0.01% (v/v) formic acid as mobile phases, and finally analyzed by HPLC-LTQ/Orbitrap in positive and negative ESI modes. The retention time and accurate mass of parent ion were used for fast screening of 22 disperse dyes, while the confirmatory analysis was obtained by fragments generated by collision-induced dissociation (CID) MS/MS. Target analysis exhibited high mass accuracy (textiles, and Disperse Orange 37/76 was detected in one of them. With high selectivity and strong anti-jamming ability, this method is simple, rapid, accurate, and it can be used for the inspection of disperse dyes in textiles.

  5. [Rapid screening and confirming carcinogenic banned azo colorants in textiles by high performance liquid chromatography-linear ion trap/orbitrap high-resolution mass spectrometry].

    Science.gov (United States)

    Yun, Huan; Liu, Xin; Wang, Jing; Yan, Hua; Cui, Fengyun; Zhang, Zhaohui

    2013-09-01

    A method of high performance liquid chromatography-linear ion trap/orbitrap highresolution mass spectrometry (HPLC-LTP/Orbitrap MS) was ued to screen and confirm-banned azo colorants in textiles rapidly. The analytes were reduced to carcinogenic aromatic amines with sodium dithionite in citrate buffer solution. The reduced solution was extracted bydiatomite, and loadd onto an Acquity UPLC BEH C18 column (50 mm x 2.1 MM. 1.7 microm) with a gradient elution of methanol and 0.1% (v/v) methane acid aqueous solution, and finally detected by linear ion trap/orbitrap high-resolution mass spectrometry in positive ESI mode. In mass spectrometry method, the MS spectrum of high-resolution and the collision induced dissociation (CID) spectrum of data-dependent scan mode were used for screening analysis and conformation, respectively. The calibration curves showed a good linearity in the range of 0.05 -2.00 mg/b, and the correlation coefficients (r) were higher than 0.99. By detecting spiked samples, the limits of quantification were 0.08 mg/kg for all the residues and the recoveries were in the range of 65.5% - 111.5% with the relative standard deviations (RSDs) between 0.87% and 2.49%. The results indicate that the method is simple, rapid, sensitive and suitable for the qualitative and quantitative analysis of carcinogenic aromatic amines in textiles.

  6. Superheated Water Ion-exchange Chromatography

    National Research Council Canada - National Science Library

    SHIBUKAWA, Masami; MORINAGA, Ryota; SAITO, Shingo

    2016-01-01

    ... superheated water chromatography. The selectivity coefficient for a pair of identically charged inorganic ions, such as alkali metal ions and halide ions, approaches unity as the temperature increases, provided that the ions...

  7. Ion Exchange and Liquid Column Chromatography.

    Science.gov (United States)

    Walton, Harold F.

    1980-01-01

    Emphasizes recent advances in principles and methodology in ion exchange and chromatography. Two tables list representative examples for inorganic ions and organic compounds. Cites 544 references. (CS)

  8. Simultaneous detection of perchlorate and bromate using rapid high-performance ion exchange chromatography-tandem mass spectrometry and perchlorate removal in drinking water.

    Science.gov (United States)

    West, Danielle M; Mu, Ruipu; Gamagedara, Sanjeewa; Ma, Yinfa; Adams, Craig; Eichholz, Todd; Burken, Joel G; Shi, Honglan

    2015-06-01

    Perchlorate and bromate occurrence in drinking water causes health concerns due to their effects on thyroid function and carcinogenicity, respectively. The purpose of this study was threefold: (1) to advance a sensitive method for simultaneous rapid detection of perchlorate and bromate in drinking water system, (2) to systematically study the occurrence of these two contaminants in Missouri drinking water treatment systems, and (3) to examine effective sorbents for minimizing perchlorate in drinking water. A rapid high-performance ion exchange chromatography-tandem mass spectrometry (HPIC-MS/MS) method was advanced for simultaneous detection of perchlorate and bromate in drinking water. The HPIC-MS/MS method was rapid, required no preconcentration of the water samples, and had detection limits for perchlorate and bromate of 0.04 and 0.01 μg/L, respectively. The method was applied to determine perchlorate and bromate concentrations in total of 23 selected Missouri drinking water treatment systems during differing seasons. The water systems selected include different source waters: groundwater, lake water, river water, and groundwater influenced by surface water. The concentrations of perchlorate and bromate were lower than or near to method detection limits in most of the drinking water samples monitored. The removal of perchlorate by various adsorbents was studied. A cationic organoclay (TC-99) exhibited effective removal of perchlorate from drinking water matrices.

  9. Ultra-high performance liquid chromatography with linear ion trap-Orbitrap hybrid mass spectrometry combined with a systematic strategy based on fragment ions for the rapid separation and characterization of components in Stellera chamaejasme extracts.

    Science.gov (United States)

    Wang, Zhixin; Qu, Yang; Wang, Li; Zhang, Xiaozhe; Xiao, Hongbin

    2016-04-01

    Stellera chamaejasme, a famous toxic herb, has been used in traditional Chinese medicine to treat various diseases. For decades, increasing attention in modern pharmacological studies has been drawn to S. chamaejasme because of its potential anti-tumor, anti-virus, and anti-fungus activities. However, due to the intrinsic complexity of chemical constitutes, hardly any investigations formed an overall recognition for the chemical profiles of this herb. In this study, a rapid and sensitive ultra-high performance liquid chromatography coupled with linear ion trap-Orbitrap mass spectrometry method was developed to characterize the chemical components of S. chamaejasme extracts. Based on optimized ultra-high performance liquid chromatography and mass spectrometry conditions and systematic fragment ions-based strategy, a total of 47 components including flavones, diterpenes, coumarins, and lignans were simultaneously detected and identified or tentatively identified for the first time. The MS(n) fragmentation patterns of all the characterized compounds in positive or negative electrospray ionization modes were also explored and summarized. These results provided essential data for further pharmacological research on S. chamaejasme. Moreover, the method was demonstrated to be an efficient tool for rapid qualitative analysis of secondary metabolites from natural resources. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Using Ion Exchange Chromatography to Separate and Quantify Complex Ions

    Science.gov (United States)

    Johnson, Brian J.

    2014-01-01

    Ion exchange chromatography is an important technique in the separation of charged species, particularly in biological, inorganic, and environmental samples. In this experiment, students are supplied with a mixture of two substitution-inert complex ions. They separate the complexes by ion exchange chromatography using a "flash"…

  11. Chromium Speciation Analysis by Ion Chromatography Coupled ...

    African Journals Online (AJOL)

    Two methods coupling ion chromatography with inductively coupled plasma - optical emission spectroscopy (ICP-OES) were developed for the simultaneous separation and determination of Cr(III) and Cr(VI) species. In the first method, anion chromatography with sodium bicarbonate/carbonate solution as the eluent was ...

  12. Rapid screening and identification of multi-class substances of very high concern in textiles using liquid chromatography-hybrid linear ion trap orbitrap mass spectrometry.

    Science.gov (United States)

    Zhang, Li; Luo, Xin; Niu, Zengyuan; Ye, Xiwen; Tang, Zhixu; Yao, Peng

    2015-03-20

    A new analytical method was established and validated for the analysis of 19 substances of very high concern (SVHCs) in textiles, including phthalic acid esters (PAEs), organotins (OTs), perfluorochemicals (PFCs) and flame retardants (FRs). After ultrasonic extraction in methanol, the textile samples were analyzed by high performance liquid chromatography-hybrid linear ion trap Orbitrap high resolution mass spectrometry (HPLC-LTQ/Orbitrap). The values of LOQ were in the range of 2-200mg/kg. Recoveries at two levels (at the LOQ and at half the limit of regulation) ranged from 68% to 120%, and the repeatability was lower than 13%. This method was successfully applied to the screening of SVHCs in commercial textile samples and is useful for the fast screening of various SVHCs. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Rapid and sensitive gas chromatography ion-trap mass spectrometry method for the determination of tobacco specific N-nitrosamines in secondhand smoke

    Energy Technology Data Exchange (ETDEWEB)

    SLEIMAN, Mohamad; MADDALENA, Randy L.; GUNDEL, Lara A.; DESTAILLATS, Hugo

    2009-07-01

    Tobacco-specific nitrosamines (TSNAs) are some of the most potent carcinogens in tobacco and cigarette smoke. Accurate quantification of these chemicals is needed to help assess public health risks. We developed and validated a specific and sensitive method to measure four TSNAs in both the gas- and particle-phase of secondhand smoke (SHS) using gas chromatography and ion-trap tandem mass spectrometry,. A smoking machine in an 18-m3 room-sized chamber generated relevant concentrations of SHS that were actively sampled on Teflon coated fiber glass (TCFG) filters, and passively sampled on cellulose substrates. A simple solid-liquid extraction protocol using methanol as solvent was successfully applied to both filters with high recoveries ranging from 85 to 115percent. Tandem MS parameters were optimized to obtain the best sensitivity in terms of signal to-noise ratio (S/N) for the target compounds. For each TSNA, the major fragmentation pathways as well as ion structures were elucidated and compared with previously published data. The method showed excellent performances with a linear dynamic range between 2 and 1000 ng mL-1, low detection limits (S/N> 3) of 30-300 pg.ml-1 and precision with experimental errors below 10percent for all compounds. Moreover, no interfering peaks were observed indicating a high selectivity of MS/MS without the need for a sample clean up step. The sampling and analysis method provides a sensitive and accurate tool to detect and quantify traces of TSNA in SHS polluted indoor environments.

  14. Rapid screening and confirmation of drugs and toxic compounds in biological specimens using liquid chromatography/ion trap tandem mass spectrometry and automated library search.

    Science.gov (United States)

    Liu, Hsiu-Chuan; Liu, Ray H; Lin, Dong-Liang; Ho, Hsiu-O

    2010-01-01

    Recent advances in liquid chromatography/tandem mass spectrometry (LC/MS/MS) technology have provided an opportunity for the development of more specific approaches to achieve the 'screen' and 'confirmation' goals in a single analytical step. For this purpose, this study adapts the electrospray ionization ion trap LC/MS/MS instrumentation (LC/ESI-MS/MS) for the screening and confirmation of over 800 drugs and toxic compounds in biological specimens. Liquid-liquid and solid-phase extraction protocols were coupled to LC/ESI-MS/MS using a 1.8-microm particle size analytical column operated at 50 degrees C. Gradient elution of the analytes was conducted using a solvent system composed of methanol and water containing 0.1% formic acid. Positive-ion ESI-MS/MS spectra and retention times for each of the 800 drugs and toxic compounds were first established using 1-10 microg/mL standard solutions. This spectra and retention time information was then transferred to the library and searched by the identification algorithm for the confirmation of compounds found in test specimens - based on retention time matches and scores of fit, reverse fit, and purity resulting from the searching process. The established method was found highly effective when applied to the analyses of postmortem specimens (blood, urine, and hair) and external proficiency test samples provided by the College of American Pathology (CAP). The development of this approach has significantly improved the efficiency of our routine laboratory operation that was based on a two-step (immunoassay and GC/MS) approach in the past. Copyright 2009 John Wiley & Sons, Ltd.

  15. Neutral fragment filtering for rapid identification of new diester-diterpenoid alkaloids in roots of Aconitum carmichaeli by ultra-high-pressure liquid chromatography coupled with linear ion trap-orbitrap mass spectrometry.

    Directory of Open Access Journals (Sweden)

    Jing Zhang

    Full Text Available A rapid and effective method was developed for separation and identification of diester-diterpenoid alkaloids (DDA in the roots of Aconitum carmichaeli by ultra-high-pressure liquid chromatography coupled with high resolution LTQ-Orbitrap tandem mass spectrometry (UHPLC-LTQ-Orbitrap-MS(n. According to accurate mass measurement and the characteristic neutral loss filtering strategy, a total of 42 diester-diterpenoid alkaloids (DDA were rapidly detected and characterized or tentatively identified. Meanwhile, the proposed fragmentation pathways and the major diagnostic fragment ions of aconitine, mesaconitine and hypaconitine were investigated to trace DDA derivatives in crude plant extracts. 23 potential new compounds were successfully screened and characterized in Aconitum carmichaeli, including 16 short chain fatty acyls DDA, 4 N-dealkyl DDA and several isomers of aconitine, mesaconitine and hypaconitine.

  16. Peak distortion effects in analytical ion chromatography.

    Science.gov (United States)

    Wahab, M Farooq; Anderson, Jordan K; Abdelrady, Mohamed; Lucy, Charles A

    2014-01-07

    The elution profile of chromatographic peaks provides fundamental understanding of the processes that occur in the mobile phase and the stationary phase. Major advances have been made in the column chemistry and suppressor technology in ion chromatography (IC) to handle a variety of sample matrices and ions. However, if the samples contain high concentrations of matrix ions, the overloaded peak elution profile is distorted. Consequently, the trace peaks shift their positions in the chromatogram in a manner that depends on the peak shape of the overloading analyte. In this work, the peak shapes in IC are examined from a fundamental perspective. Three commercial IC columns AS16, AS18, and AS23 were studied with borate, hydroxide and carbonate as suppressible eluents. Monovalent ions (chloride, bromide, and nitrate) are used as model analytes under analytical (0.1 mM) to overload conditions (10-500 mM). Both peak fronting and tailing are observed. On the basis of competitive Langmuir isotherms, if the eluent anion is more strongly retained than the analyte ion on an ion exchanger, the analyte peak is fronting. If the eluent is more weakly retained on the stationary phase, the analyte peak always tails under overload conditions regardless of the stationary phase capacity. If the charge of the analyte and eluent anions are different (e.g., Br(-) vs CO3(2-)), the analyte peak shapes depend on the eluent concentration in a more complex pattern. It was shown that there are interesting similarities with peak distortions due to strongly retained mobile phase components in other modes of liquid chromatography.

  17. Characterization of synthetic dyes by comprehensive two-dimensional liquid chromatography combining ion-exchange chromatography and fast ion-pair reversed-phase chromatography.

    Science.gov (United States)

    Pirok, Bob W J; Knip, Jitske; van Bommel, Maarten R; Schoenmakers, Peter J

    2016-03-04

    In the late 19th century, newly invented synthetic dyes rapidly replaced the natural dyes on the market. The characterization of mixtures of these so-called early synthetic dyes is complicated through the occurrence of many impurities and degradation products. Conventional one-dimensional liquid chromatography does not suffice to obtain fingerprints with sufficient resolution and baseline integrity. Comprehensive two-dimensional liquid chromatography (LC×LC) is employed in this study, with ion-exchange chromatography in the first dimension and fast ion-pair liquid chromatography in the second. Retention in the first dimension is largely determined by the number of charges, while the selection of a small ion-pair reagent (tetramethylammonium hydroxide) in the second dimension causes retention to be largely determined by the molecular structure of the dye. As a result, there is a high degree of orthogonality of the two dimensions, similar to the values typically encountered in GC×GC. The proposed LC×LC method shows a theroretical peak capacity of about 2000 in an analysis time of about three hours. Clear, informative fingerprints are obtained that open a way to a more efficient characterization of dyes used in objects of cultural heritage. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. An Empirical Formula From Ion Exchange Chromatography and Colorimetry.

    Science.gov (United States)

    Johnson, Steven D.

    1996-01-01

    Presents a detailed procedure for finding an empirical formula from ion exchange chromatography and colorimetry. Introduces students to more varied techniques including volumetric manipulation, titration, ion-exchange, preparation of a calibration curve, and the use of colorimetry. (JRH)

  19. Ion Exchange Chromatography and Spectrophotometry: An Introductory Undergraduate Laboratory Experiment.

    Science.gov (United States)

    Foster, N.; And Others

    1985-01-01

    Describes an experiment in which students use ion exchange chromatography to separate a mixture of chloro complexes of transition metal ions and then use spectrophotometry to define qualitatively the efficiency of the ion exchange columns. Background information, materials needed, and procedures used are included. (JN)

  20. Measuring the Epoxy Content of Aerosols Using Ion Chromatography

    National Research Council Canada - National Science Library

    Vietas, Jay

    2000-01-01

    ...), were analyzed using ion chromatography to determine recovery rates of the model compound. Recovery rates for five different loading levels were compared to guidelines set forth by the National Institute for Occupational Health and Safety (NIOSH...

  1. Chromatography Of Metal Ions On Wood Cellulose Impregnated ...

    African Journals Online (AJOL)

    Adsorption chromatography of some heavy metal ions on wood cellulose of saw dust (wood waste dust) modified with hydrochloric acid, urea and thiourea was studied. Atomic absorption spectrophotometry (AAS) was used to determine the initial concentration of solutions of Zn2+, Cu2+, Ni2+, Pb2+, and Fe3+ metal ions.

  2. Recent advances in polymer monoliths for ion-exchange chromatography.

    Science.gov (United States)

    Nordborg, Anna; Hilder, Emily F

    2009-05-01

    The use of polymeric materials in ion-exchange chromatography applications is advantageous because of their typically high mechanical stability and tolerance of a wide range of pH conditions. The possibility of using polymeric monoliths in ion-exchange chromatography is therefore obvious and many of the same strategies developed for polymeric particles have been adapted for use with polymeric monoliths. In this review different strategies for the synthesis of polymeric monoliths with ion-exchange functionality are discussed. The incorporation of ion-exchange functionality by co-polymerization is included, as also are different post-polymerization alterations to the monolith surface such as grafting. The formulations and strategies presented include materials intended for use in analytical separations in ion-exchange chromatography, sample pre-treatment or enrichment applications, and materials for capillary electrochromatography. Finally, examples of the use of polymeric monoliths in ion-exchange chromatography applications are included with examples published in the years 2003 to 2008.

  3. Chromium Speciation Analysis by Ion Chromatography Coupled ...

    African Journals Online (AJOL)

    2003-09-21

    Sep 21, 2003 ... Inductively Coupled Plasma – Optical Emission Spectroscopy. The chromatographic columns were coupled with a Varian. Liberty 110 ICP Emission Spectrometer via a V-groove nebulizer. Data capturing and peak analyses were performed with the use of Star Chromatography Software.31 The optimized ...

  4. Ion exchange chromatography – basic principles and application

    OpenAIRE

    Cummins, Phil; Dowling, Oonagh; O'Connor, Brendan

    2011-01-01

    Ion-Exchange Chromatography (IEC) allows for the separation of ionizable molecules on the basis of differences in charge properties. Its large sample-handling capacity, broad applicability (particularly to proteins and enzymes), moderate cost, powerful resolving ability, and ease of scale-up and automation have led to it becoming one of the most versatile and widely used of all liquid chromatography (LC) techniques. In this chapter, we review the basic principles of IEC, as well as the broade...

  5. Rapid miniaturized chromatography for Tc-99m IDA agents: comparison with gel chromatography.

    Science.gov (United States)

    Zimmer, A M; Majewski, W; Spies, S M

    1982-01-01

    Miniaturized chromatography systems for determining free pertechnetate and hydrolyzed reduced 99mTc levels in commercial 99mTc-labeled iminodiacetate (IDA) hepatobiliary radiopharmaceuticals were evaluated and the results compared with gel chromatography column scanning (GCS). Commercial IDA agents were evaluated including 2,6-dimethyl IDA, p-isopropyl IDA, p-butyl IDA, and 2,6-diisopropyl IDA. Of all the chromatography systems evaluated, only Gelman ITLC-SA with 20% NaCl and Gelman ITLC-SG with distilled water correlated with GCS in evaluating free pertechnetate and hydrolyzed reduced 99mTc levels for all IDA radiopharmaceuticals. The miniaturized chromatography procedure, as outlined, is rapid, taking less than 4 min, and can easily be incorporated into the daily quality control program in any nuclear medicine facility.

  6. Using ion exchange chromatography to purify a recombinantly expressed protein.

    Science.gov (United States)

    Duong-Ly, Krisna C; Gabelli, Sandra B

    2014-01-01

    Ion exchange chromatography (IEX) separates molecules by their surface charge, a property that can vary vastly between different proteins. There are two types of IEX, cation exhange and anion exchange chromatography. The protocol that follows was designed by the authors for anion exchange chromatography of a recombinantly expressed protein having a pI of 4.9 and containing two cysteine residues and one tryptophan residue, using an FPLC system. Prior to anion exchange, the protein had been salted out using ammonium sulfate precipitation and partially purified via hydrophobic interaction chromatography (see Salting out of proteins using ammonium sulfate precipitation and Use and Application of Hydrophobic Interaction Chromatography for Protein Purification). Slight modifications to this protocol may be made to accommodate both the protein of interest and the availability of equipment. © 2014 Elsevier Inc. All rights reserved.

  7. ANALYSIS OF FERRIC AND FERROUS IONS IN SOIL EXTRACTS BY ION CHROMATOGRAPHY

    Science.gov (United States)

    A method using ion chromatography (IC) for the analysis of ferrous (Fe 2+) and ferric (Fe 3+) ions in soil extracts has been developed. This method uses an ion exchange column with detection at 520 nm after post-column derivatization. Selectivity is achieved by using an anionic...

  8. ISCO Grab Sample Ion Chromatography Analytical Data

    Data.gov (United States)

    U.S. Environmental Protection Agency — ISCO grab samples were collected from river, wastewater treatment plant discharge, and public drinking water intakes. Samples were analyzed for major ions (ppb)...

  9. Mineral Separation in a CELSS by Ion-exchange Chromatography

    Science.gov (United States)

    Ballou, E. V.; Spitze, L. A.; Wong, F. W.; Wydeven, T.; Johnson, C. C.

    1982-01-01

    Operational parameters pertinent to ion exchange chromatography separation were identified. The experiments were performed with 9 mm diameter ion exchange columns and conventional column accessories. The cation separation beds were packed with AG 50W-X2 strong acid cation exchange resin in H(+) form and 200-400 dry mesh particle size. The stripper beds used in some experiments were packed with AG 1-XB strong base cation exchange resin in OH(-) form and 200-400 dry mesh particle size.

  10. Determination of Nicotine in Smoke Condensate by Ion Chromatography Coupled to Ultraviolet Detection

    Directory of Open Access Journals (Sweden)

    Geiss O

    2014-12-01

    Full Text Available A new method for the determination of the nicotine content of tobacco smoke condensate is described. The smoke condensate of the mainstream smoke was collected in a glass fibre filter trap and dissolved in isopropanol. The nicotine content of an aliquot of this solution was determined by ion chromatography (IC coupled with ultraviolet (UV detection against external calibration and the nicotine content of the whole smoke condensate was calculated. The nicotine content determined in each run by IC was compared with the results obtained by gas chromatography (GC according to the International Standard (ISO method 10315. The present method represents a potential alternative to the GC method. A sensitive and rapid method for the determination of nicotine in smoke condensate using IC with a standard ion chromatography column was developed.

  11. Simultaneous Determination of Chelating Agents by Ion-Suppression and Ion-Pair Chromatography in Wastewater

    Energy Technology Data Exchange (ETDEWEB)

    Dodi, Alain; Bouscarel, Maelle [Commissariat a l' energie atomique - C.E.A, Centre d' Etude de Cadarache, Laboratoire d' Analyses Radiochimiques et Chimiques, St Paul lez Durance (France)

    2008-07-01

    This article describes two methods for analysing chelating agents found in nuclear waste. First, ion-suppression chromatography using an anion exchange stationary phase and mobile phase consisting of a nitric acid solution and pure water gradient. UV detection was performed at 330 nm after the reaction with a post-column reagent composed of iron nitrate in perchloric acid. Secondly, ion-pair chromatography with a mobile phase consisting of a mixture of nitric acid, tetra-butyl-ammonium hydrogeno-sulphate, tetra-butyl-ammonium hydroxide and iron chloride. A reversed-phase material was used as a stationary phase and detection was performed by direct measurement of the UV absorption at 260 nm. The quantification limits were lower for ion-pair chromatography than for ion-suppression chromatography. Both methods were easy to implement and allow a multi-element separation in less than 30 min with low detection limits. (authors)

  12. A novel silica based click lysine anion exchanger for ion exchange chromatography.

    Science.gov (United States)

    Guo, Hongyue; Chu, Changhu; Li, Yan; Yang, Bingcheng; Liang, Xinmiao

    2011-12-21

    Ion chromatography (IC) is one of the most powerful analysis technologies for the determination of charged compounds. A novel click lysine stationary phase was prepared via Cu(I) catalyzed alkyne-azide 1,3-dipolar cycloaddition (CuAAC) and applied to the analysis of inorganic ions. The chromatographic evaluation demonstrated good performance (e.g. the plate number of thiocyanate is ∼50,000 plates m(-1)) and effective separation ability for the common inorganic anions with aqueous Na(2)SO(4) eluent. The separation mechanism was observed to be mainly dominated by ion exchange interaction. The retention of these analytes is highly dependent on the pH value of eluent. Compared with the lysine stationary phase prepared via the conventional manner, the click lysine exchanger demonstrated shorter retention time and better ion separation characteristics under the same chromatographic conditions, which is a great advantage for rapid separation and analysis of inorganic ions.

  13. Chromatography

    Science.gov (United States)

    ... that are bonded together. For example, water is a chemical bond of oxygen and hydrogen. Proteins are another type of chemical compound. There are different kinds of chromatography. These include gas, high pressure liquid, or ion ...

  14. Ion-Exchange Chromatography: Basic Principles and Application.

    Science.gov (United States)

    Cummins, Philip M; Rochfort, Keith D; O'Connor, Brendan F

    2017-01-01

    Ion-Exchange Chromatography (IEC) allows for the separation of ionizable molecules on the basis of differences in charge properties. Its large sample-handling capacity, broad applicability (particularly to proteins and enzymes), moderate cost, powerful resolving ability, and ease of scale-up and automation have led to it becoming one of the most versatile and widely used of all liquid chromatography (LC) techniques. In this chapter, we review the basic principles of IEC, as well as the broader criteria for selecting IEC conditions. By way of further illustration, we outline basic laboratory protocols to partially purify a soluble serine peptidase from bovine whole brain tissue, covering crude tissue extract preparation through to partial purification of the target enzyme using anion-exchange chromatography. Protocols for assaying total protein and enzyme activity in both pre- and post-IEC fractions are also described.

  15. Simultaneous determination of inorganic and organic anions by ion chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Park, Yang Soon; Joe, Ki Soo; Han, Sun Ho; Park, Soon Dal; Choi, Kwang Soon

    1999-06-01

    Four methods were investigated for the simultaneous determination of several inorganic and organic anions in aqueous solution by ion chromatography. The first is two columns coupled system. The second is the gradient elution system with an anion exchange column. The third is the system with a mixed-mode stationary phase. The fourth is the system with an anion exchange column and the eluant of low conductivity without ion suppressor. The advantages and disadvantages of individual systems were discussed. The suitable methods were proposed for the application to the samples of the nuclear power industry and the environment. (author)

  16. Comprehensive two-dimensional liquid chromatography: Ion chromatography × reversed-phase liquid chromatography for separation of low-molar-mass organic acids

    NARCIS (Netherlands)

    Brudin, S.S.; Shellie, R.A.; Haddad, P.R.; Schoenmakers, P.J.

    2010-01-01

    In the work presented here a novel approach to comprehensive two-dimensional liquid chromatography is evaluated. Ion chromatography is chosen for the first-dimension separation and reversed-phase liquid chromatography is chosen for the second-dimension separation mode. The coupling of these modes is

  17. Models for prediction of retention in nonsuppressed ion chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Jenke, D.R.; Pagenkopf, G.K.

    1984-01-01

    The retention behavior of Br/sup -/, NO/sub 3//sup -/, Cl/sup -/, SO/sub 4//sup 2 -/, and S/sub 2/O/sub 3//sup 2 -/ in nonsuppressed ion chromatography is studied as a function of changing eluent composition. Three models, multiple species eluent, single species eluent, and single interaction sites, are utilized to predict chromatographic behavior. While all three are based on a thermodynamic equilibrium consideration of the ion exchange process, they differ in their characterization of the analyte/eluent competition or the ion/resin interaction. Despite this difference in approach, all three models effectively characterize the behavior of the analytes under elution conditions which are of practical importance. The relative utility of each model is discussed. 17 references, 4 tables.

  18. Low-temperature Conductivity Detection for Ultrasensitive Ion Chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Eom, Jiwon; Lee, Dong Soo [Yonsei University, Seoul (Korea, Republic of)

    2016-03-15

    The effects of conductivity detection temperature on calibration sensitivity and linearity in suppressed ion chromatography using hydronium or hydroxide eluent were investigated. Theoretical calibration curves for lithium and nitrate ions at 0-35 .deg. C were calculated and compared with experimental data. As the detection temperature was lowered, both sensitivity and linearity of calibration at low concentrations were improved due to the reduced interference by water autoionization equilibrium; 4.3- and 1.3-fold increases in linear regression slopes were observed in the 0-1 μmol/L range when the temperature was lowered from 35 to 5 .deg. C for lithium and nitrate,respectively, along with significant increases in the correlation coefficient. Any remaining water autoionization effect was near completely removed by using eluents contaminated with rubidium or bromide ion at 0.1 μmol/L.

  19. A rapid liquid chromatography determination of free formaldehyde in cod.

    Science.gov (United States)

    Storey, Joseph M; Andersen, Wendy C; Heise, Andrea; Turnipseed, Sherri B; Lohne, Jack; Thomas, Terri; Madson, Mark

    2015-01-01

    A rapid method for the determination of free formaldehyde in cod is described. It uses a simple water extraction of formaldehyde which is then derivatised with 2,4-dinitrophenylhydrazine (DNPH) to form a sensitive and specific chromophore for high-performance liquid chromatography (HPLC) detection. Although this formaldehyde derivative has been widely used in past tissue analysis, this paper describes an improved derivatisation procedure. The formation of the DNPH formaldehyde derivative has been shortened to 2 min and a stabilising buffer has been added to the derivative to increase its stability. The average recovery of free formaldehyde in spiked cod was 63% with an RSD of 15% over the range of 25-200 mg kg(-1) (n = 48). The HPLC procedure described here was also compared to a commercial qualitative procedure - a swab test for the determination of free formaldehyde in fish. Several positive samples were compared by both methods.

  20. Manipulating adenoviral vector ion-exchange chromatography: Hexon versus fiber.

    Science.gov (United States)

    Ruščić, Jelena; Ambriović-Ristov, Andreja; Majhen, Dragomira; Kolundžija, Sandra; Barut, Miloš; Benihoud, Karim; Krajačić, Mladen

    2016-11-01

    The serotype specificity of adenovirus ion-exchange chromatography has previously been studied using standard particle-based columns, and the hexon protein has been reported to determine retention time. In this study, we have submitted Adenovirus type 5 recombinants to anion-exchange chromatography using methacrylate monolithic supports. Our experiments with hexon-modified adenoviral vectors show more precisely that the retention time is affected by the substitution of amino acids in hypervariable region 5, which lies within the hexon DE1 loop. By exploring the recombinants modified in the fiber protein, we have proven the previously predicted chromatographic potential of this surface constituent. Modifications that preserve the net charge of the hexon protein, or those that cause only a small charge difference in the fiber protein, in addition to shortening the fiber shaft, did not change the chromatographic behavior of the adenovirus particles. However, modifications that include the deletion of just two negatively charged amino acids in the hexon protein, or the introduction of a heterologous fiber protein, derived from another serotype, revealed recognizable changes in anion-exchange chromatography. This could be useful in facilitating chromatography-approach purification by creating targeted capsid modifications, thereby shifting adenovirus particles away from particular interfering substances present in the crude lysate. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Ion-exchange chromatography purification of extracellular vesicles.

    Science.gov (United States)

    Kosanović, Maja; Milutinović, Bojana; Goč, Sanja; Mitić, Ninoslav; Janković, Miroslava

    2017-08-01

    Despite numerous studies, isolating pure preparations of extracellular vesicles (EVs) has proven challenging. Here, we compared ion-exchange chromatography (IEC) to the widely used sucrose density gradient (SDG) centrifugation method for the purification of EVs. EVs in bulk were isolated from pooled normal human amniotic fluid (AF) by differential centrifugation followed by IEC or sucrose density gradient separation. The purity of the isolated EVs was evaluated by electrophoresis and lectin blotting/immuno blotting to monitor the distribution of total proteins, different EVs markers, and selected N-glycans. Our data showed efficient separation of negatively charged EVs from other differently charged molecules, while comparative profiling of EVs using SDG centrifugation confirmed anion-exchange chromatography is advantageous for EV purification. Finally, although this IEC-based method was validated using AF, the approach should be readily applicable to isolation of EVs from other sources as well.

  2. Ion chromatography in the manufacture of multilayer circuit boards

    Science.gov (United States)

    Smith, R. E.

    1987-10-01

    Ion chromatography (IC) has proven useful in analyzing chemical solutions used in the manufacture of multilayer circuit boards. IC provides results on ions not expected in the production solutions. Thus, solution contamination and breakdown products can be monitored in every phase of the circuit board manufacturing. During the first phase, epoxy laminates experience an etchback, first in chromic acid, which can be analyzed for trace chloride and sulfate, then in ammonium bifluoride/HCl, which can be analyzed for fluoride and chloride. Following a wet blasting to roughen up the surface, 20 mu in. of copper are deposited using an electroless bath. Again, IC is applicable for monitoring formate, tartarate, and sulfate levels. Next, an acid copper bath is used to electroplate the through holes with 0.001 in. of ductile copper. This bath is analyzed for trace chloride. Photoimaging is then performed, and the organic solvents used can be assayed for trace ionic chloride. Finally, a fluoroboric acid-based tin-lead bath is used to deposit a solderable alloy. This bath is analyzed for total fluoroborate, tin, and lead. In addition, mobile phase ion chromatography (MPIC) is used to monitor the nonionic organic brighteners in the baths.

  3. Determination of trimethylselenonium ion in urine by ion chromatography and inductively coupled plasma mass spectrometry detection

    DEFF Research Database (Denmark)

    Gammelgaard, Bente; Jessen, K.D.; Kristensen, F.H.

    2000-01-01

    The selenium species selenite, selenate, selenomethionine (SeMet), and trimethylselenonium iodide (TMSe+) were separated in aqueous solution by ion chromatography. The separation was performed on an Ionpac CS5 cation exchange column by elution with 10 mM oxalic acid and 20 mM potassium sulphate, p...

  4. What can in situ ion chromatography offer for Mars exploration?

    Science.gov (United States)

    Shelor, C Phillip; Dasgupta, Purnendu K; Aubrey, Andrew; Davila, Alfonso F; Lee, Michael C; McKay, Christopher P; Liu, Yan; Noell, Aaron C

    2014-07-01

    The successes of the Mars exploration program have led to our unprecedented knowledge of the geological, mineralogical, and elemental composition of the martian surface. To date, however, only one mission, the Phoenix lander, has specifically set out to determine the soluble chemistry of the martian surface. The surprising results, including the detection of perchlorate, demonstrated both the importance of performing soluble ion measurements and the need for improved instrumentation to unambiguously identify all the species present. Ion chromatography (IC) is the state-of-the-art technique for soluble ion analysis on Earth and would therefore be the ideal instrument to send to Mars. A flight IC system must necessarily be small, lightweight, low-power, and have low eluent consumption. We demonstrate here a breadboard system that addresses these issues by using capillary IC at low flow rates with an optimized eluent generator and suppressor. A mix of 12 ions known or plausible for the martian soil, including 4 (oxy)chlorine species, has been separated at flow rates ranging from 1 to 10 μL/min, requiring as little as 200 psi at 1.0 μL/min. This allowed the use of pneumatic displacement pumping from a pressurized aluminum eluent reservoir and the elimination of the high-pressure pump entirely (the single heaviest and most energy-intensive component). All ions could be separated and detected effectively from 0.5 to 100 μM, even when millimolar concentrations of perchlorate were present in the same mixtures.

  5. Determination of sulphite in wines using suppressed ion chromatography.

    Science.gov (United States)

    Yoshikawa, Kenji; Uekusa, Yuki; Sakuragawa, Akio

    2015-05-01

    Suppressed ion chromatography with the use of a conductivity detector was developed for the determination of sulphite ions in wine samples. When a mixed solution of sodium carbonate, sodium bicarbonate, and acetone was used as the mobile phase, simultaneous determination of eight inorganic anions (i.e., fluoride, chloride, nitrite, nitrate, sulphite, phosphate, sulphate, and thiosulphate) was completed in approximately 25 min. Linearity, reproducibility, and detection limits were determined for the proposed method. In the case of sulphite detection, a linear calibration curve with a good correlation coefficient of 0.9992 was obtained from the peak height of sulphite with a relative standard deviation (n = 6) 1.48%. In addition, the detection limit of sulphite was 0.27 mg/L at a signal-to-noise ratio of 3. Further, the developed method was applied for the determination of sulphite contained in several wine samples. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Recent progress and applications of ion-exclusion/ion-exchange chromatography for simultaneous determination of inorganic anions and cations.

    Science.gov (United States)

    Nakatani, Nobutake; Kozaki, Daisuke; Mori, Masanobu; Tanaka, Kazuhiko

    2012-01-01

    One of the ultimate goals of ion chromatography is to determine both anions and cations found in samples with a single chromatographic run. In the present article, recent progress in ion-exclusion/ion-exchange chromatography for the simultaneous determinations of inorganic anions and cations are reviewed. Firstly, the principle and the control for the simultaneous separation and detection of analyte ions using ion-exclusion/cation-exchange chromatography with a weakly acidic cation-exchange column are outlined. Then, advanced chromatographic techniques in terms of analytical time, selectively and sensitivity are summarized. As a related method, ion-exclusion/anion-exchange chromatography with an anion-exchange column could be used for the simultaneous determination of inorganic nitrogen species, such as ammonium, nitrite and nitrate ions. Their usefulness and applications to water-quality monitoring and related techniques are also described.

  7. Determination of γ-hydroxybutyrate in human urine samples by ion exclusion and ion exchange two-dimensional chromatography system.

    Science.gov (United States)

    Liu, Junwei; Deng, Zhifen; Zhu, Zuoyi; Wang, Yong; Wang, Guoqing; Sun, Yu-An; Zhu, Yan

    2017-12-15

    A two-dimensional ion chromatography system was developed for the determination of γ-hydroxybutyrate (GHB) in human urine samples. Ion exclusion chromatography was used in the first dimensional separation for elimination of urine matrices and detection of GHB above 10mgL-1, ion exchange chromatography was used in the second dimensional separation via column-switching technique for detection of GHB above 0.08mgL-1. Under the optimized chromatographic conditions, the ion exclusion and ion exchange chromatography separation system exhibited satisfactory repeatability (RSDion chromatography system was convenient and practical for the determination of GHB in human urine samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Ion Chromatography-on-a-chip for Water Quality Analysis

    Science.gov (United States)

    Kidd, R. D.; Noell, A.; Kazarians, G.; Aubrey, A. D.; Scianmarello, N.; Tai, Y.-C.

    2015-01-01

    We report progress towards developing a Micro-Electro-Mechanical Systems (MEMS)- based ion chromatograph (IC) for crewed spacecraft water analysis. This IC-chip is an offshoot of a NASA-funded effort to produce a high performance liquid chromatograph (HPLC)-chip. This HPLC-chip system would require a desalting (i.e. ion chromatography) step. The complete HPLC instrument consists of the Jet Propulsion Labortory's (JPL's) quadrupole ion trap mass spectrometer integrated with a state-of-the-art MEMS liquid chromatograph (LC) system developed by the California Institute of Technology's (Caltech's) Micromachining Laboratory. The IC version of the chip consist of an electrolysis-based injector, a separation column, two electrolysis pumps for gradient generation, mixer, and a built-in conductivity detector. The HPLC version of the chip also includes a nanospray tip. The low instrument mass, coupled with its high analytical capabilities, makes the LC chip ideally suitable for wide range of applications such as trace contaminant, inorganic analytical science and, when coupled to a mass spectrometer, a macromolecular detection system for either crewed space exploration vehicles or robotic planetary missions.

  9. Rapid confirmatory analysis of avermectin residues in milk by liquid chromatography tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    Nurullah Ozdemir

    2016-01-01

    Full Text Available Our study developed a quick method for confirmatory analysis of avermectins (abamectin B1a, doramectin, ivermectin B1a, eprinomectin B1a, and moxidectin in bovine milk according to the European Commission Decision 2002/657/EC requirements. Avermectins were liquid–liquid extracted with acetonitrile, followed by an evaporation step, and then analyzed by liquid chromatography/electrospray ionization tandem mass spectrometry in the negative ion mode. An in-house method validation was performed and the data reported on specificity, linearity, recovery, limit of detection, limit of quantitation, decision limit, and detection capability. The advantage of this method is that low levels of avermectins are detectable and quantitatively confirmed at a rapid rate in milk.

  10. Analysis of N-nitrosodiethylamine by ion chromatography coupled with UV photolysis pretreatment

    Directory of Open Access Journals (Sweden)

    Xueli Li

    2016-04-01

    Full Text Available Nitrosamines such as N-nitrosodiethylamine (NDEA are commonly detected by spectrophotometry after photolysis and Griess reaction (PG in food industries for lower cost. Results of this research indicate that NDEA decays rapidly under UV irradiation, and concentrations of the generated NO2− and NO3− ions vary with photolysis conditions. Thus, the measurement of the PG method may be inconsistent because it is based on the amount of photoproduced NO2−. In addition, more errors may be present in the PG method since NO3− cannot be measured colorimetrically using Griess reagent. In this work, the sum of the concentrations of photoproduced NO2− and NO3− was found to be equivalent to the initial NDEA before photolysis, and a photolysis–ion chromatography method was validated, which may serve as a feasible and accurate method to determine nitrosamines.

  11. Kinetic studies of clavulanic acid recovery by ion exchange chromatography.

    Science.gov (United States)

    Barboza, M; Almeida, R M; Hokka, C O

    2001-01-01

    Clavulanic acid (CA) is a beta-lactamase inhibitor produced by strains of Streptomyces clavuligerus. Nowadays, the combination of CA with amoxycillin is the most successful example of the use of a beta-lactam antibiotic sensitive to beta-lactamases together with an inhibitor of these enzymes. Clavulanic acid is purified from fermentation broth by a series of steps consisting mainly of two-phase separation processes such as liquid-liquid extraction, adsorption or ion-exchange chromatography, among others. Amberlite IRA 400, a strong anion-exchange resin, has a very high adsorption capacity for CA (Mayer et al. 1997). This resin can be pre-treated with NaCl (chloride cycle), to remove selectively only those anions, which are able to displace chloride from the resin or with NaOH (hydroxyl cycle), to remove all species of anions. In order to decide the best operating conditions for CA recovery by ion-exchange resins and then to construct a model of this separation process, batch experiments were conducted using Amberlite IRA 400 in the chloride cycle. These runs were carried out in a 200 ml stirred tank, at two different initial solution pH, 6.2 and 4.0; the temperature was maintained at 10 degrees C and 20 degrees C during adsorption and 30 degrees C during the desorption step. It was possible, on the basis of these batch results, to model the separation process, including the adsorption kinetics, equilibrium data and mass transfer limitations.

  12. Chromatography of metal ions with a triazine chelating resin

    Energy Technology Data Exchange (ETDEWEB)

    Wang, W.N.

    1979-05-01

    The synthesis, characterization, and some analytical applications of a new triazine resin are described. Separation of group IB, IIB, VIB, and VIIB metal ions from group VIII metal ions is achieved by this PDT-4 resin. Calcium(II) and magnesium(II) are taken up at pH = 6, 0.1 M acetate and are eluted at pH = 6, 0.1 M sodium nitrate. Copper(II) is retained at pH = 6, 0.1 M acetate and pH = 1 hydrochloric acid and is eluted subsequently by 5 M perchloric acid. Molybdenum(VI) is sorbed selectively from 0.1 N sulfuric acid or hydrochloric acid and is eluted in a tight band by 0.1 N sodium hydroxide. Numerous rapid column chromatographic separations are reported using this new resin, including analysis of NBS standard samples.

  13. Three dimensional liquid chromatography coupling ion exchange chromatography/hydrophobic interaction chromatography/reverse phase chromatography for effective protein separation in top-down proteomics.

    Science.gov (United States)

    Valeja, Santosh G; Xiu, Lichen; Gregorich, Zachery R; Guner, Huseyin; Jin, Song; Ge, Ying

    2015-01-01

    To address the complexity of the proteome in mass spectrometry (MS)-based top-down proteomics, multidimensional liquid chromatography (MDLC) strategies that can effectively separate proteins with high resolution and automation are highly desirable. Although various MDLC methods that can effectively separate peptides from protein digests exist, very few MDLC strategies, primarily consisting of 2DLC, are available for intact protein separation, which is insufficient to address the complexity of the proteome. We recently demonstrated that hydrophobic interaction chromatography (HIC) utilizing a MS-compatible salt can provide high resolution separation of intact proteins for top-down proteomics. Herein, we have developed a novel 3DLC strategy by coupling HIC with ion exchange chromatography (IEC) and reverse phase chromatography (RPC) for intact protein separation. We demonstrated that a 3D (IEC-HIC-RPC) approach greatly outperformed the conventional 2D IEC-RPC approach. For the same IEC fraction (out of 35 fractions) from a crude HEK 293 cell lysate, a total of 640 proteins were identified in the 3D approach (corresponding to 201 nonredundant proteins) as compared to 47 in the 2D approach, whereas simply prolonging the gradients in RPC in the 2D approach only led to minimal improvement in protein separation and identifications. Therefore, this novel 3DLC method has great potential for effective separation of intact proteins to achieve deep proteome coverage in top-down proteomics.

  14. Rapid separation of beryllium and lanthanide derivatives by capillary gas chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Harvey, Scott D.; Lucke, Richard B.; Douglas, Matt

    2012-09-04

    Previous studies describe derivatization of metal ions followed by analysis using gas chromatography, usually on packed columns. In many of these studies, stable and volatile derivatives were formed using fluorinated β-diketonate reagents. This paper extends previous work by investigating separations of the derivatives on small-diameter capillary gas chromatography columns and exploring on-fiber, solid-phase microextraction derivatization techniques for beryllium. The β-diketonate used for these studies was 1,1,1,2,2,6,6,7,7,7-decafluoro-3,5-heptanedione. Derivatization of lanthanides also required addition of a neutral donor, dibutyl sulfoxide, in addition to 1,1,1,2,2,6,6,7,7,7-decafluoro-3,5-heptanedione. Unoptimized separations on a 100-μm i.d. capillary column proved capable of rapid separations (within 15 min) of lanthanide derivatives that are adjacent to one another in the periodic table. Full-scan mass spectra were obtained from derivatives containing 5 ng of each lanthanide. Studies also developed a simple on-fiber solid-phase microextraction derivatization of beryllium. Beryllium could be analyzed in the presence of other alkali earth elements (Ba(II) and Sr(II)) without interference. Finally, extension of the general approach was demonstrated for several additional elements (i.e. Cu(II), Cr(III), and Ga(III)).

  15. A rapid analysis of plasma/serum ethylene and propylene glycol by headspace gas chromatography

    National Research Council Canada - National Science Library

    Ehlers, Alexandra; Morris, Cory; Krasowski, Matthew D

    2013-01-01

    A rapid headspace-gas chromatography (HS-GC) method was developed for the analysis of ethylene glycol and propylene glycol in plasma and serum specimens using 1,3-propanediol as the internal standard...

  16. Continuous measurement of macronutrient ions in the transpiration stream of intact plants using the meadow spittlebug coupled with ion chromatography.

    Science.gov (United States)

    Malone, Michael; Herron, Michelle; Morales, M-Angeles

    2002-11-01

    A method is described for continuous, nondestructive analysis of xylem-borne mineral nutrients in intact transpiring plants. The method uses the xylem-feeding insect the meadow spittlebug (Philaenus spumarius L. [Homoptera: Cercopidae]). This insect will feed from a wide range of plant species and organs. Insect excreta can be collected at all times of the day and night, and its mineral ion content can be analyzed rapidly, and without purification, by ion chromatography. The excreta will have a mineral content virtually identical to that of xylem sap. Cages suitable for containing the insects and collecting excreta from any desired location on plants in both laboratory and greenhouse are described. Even in the greenhouse, evaporation had only a minor effect on the sample ion content. Example results are presented which illustrate dynamics, over several days, in the xylem concentrations of sodium (Na(+)), potassium (K(+)), NH(4)(+), magnesium (Mg(2+)), calcium (Ca(2+)), chloride (Cl(-)), NO(3)(-), PO(4)(3-), and SO(4)(2-). These data were collected from young plants growing in pots of compost in the laboratory and from fully mature pepper (Capsicum annuum L. cv Bellboy) plants growing in hydroponics (rockwool) in the greenhouse. This method should facilitate studies of macronutrient uptake and transport in a range of plants and environments.

  17. Rapid, high performance method for the determination of vitamin K(1), menaquinone-4 and vitamin K(1) 2,3-epoxide in human serum and plasma using liquid chromatography-hybrid quadrupole linear ion trap mass spectrometry.

    Science.gov (United States)

    Gentili, Alessandra; Cafolla, Arturo; Gasperi, Tecla; Bellante, Simona; Caretti, Fulvia; Curini, Roberta; Fernández, Virginia Pérez

    2014-04-18

    Unlike the other fat-soluble vitamins, vitamin K circulates in the human bloodstream at very low levels because of a low intake in the diet. Mammals have developed an efficient recycling system, known as vitamin K-epoxide cycle, which involve quinone, hydroquinone and epoxide forms of the vitamin. Phylloquinone (K(1)) is the main homologue, while menaquinone-4 (MK-4) is both a member of the vitamin K(2) family and metabolite of K(1) in extra-hepatic tissues. Notwithstanding the recent advances, many aspects of the complex vitamin K physiology still remain to be investigated. Therefore, there is a critical need to develop more reliable analytical methods for determining the vitamin K and its metabolites in biological fluids and tissues. Nevertheless, relatively low concentrations, unavailability of some authentic standards and occurrence of interfering lipids make this a challenging task. The method proposed in the present paper can directly and accurately estimate K(1), K(1) 2,3-epoxide (K(1)O), and MK-4 in human serum and plasma at concentrations in the ng/L-μg/L range, using labelled internal standards and a quadrupole linear ion trap instrument operated in multiple reaction monitoring (MRM) mode. High sensitivity was achieved by removing signal "endogenous suppressors" and making the composition of the non-aqueous mobile phase suitable to support the positive atmospheric pressure chemical ionization of the analytes. An excellent selectivity resulted from the combination of some factors: the MRM acquisition, the adoption of an identification point system, an extraction optimized to remove most of the lipids and a tandem-C18 column-system necessary to separate isobaric interferences from analytes. The method was validated according to the Food and Drug Administration (FDA) guidelines and its accuracy was assessed by analysing 9 samples from the Vitamin K External Quality Assessment Scheme (KEQAS). Its feasibility in evaluating vitamin K status in human serum was

  18. Thin layer chromatography-ion mobility spectrometry (TLC-IMS).

    Science.gov (United States)

    Ilbeigi, Vahideh; Tabrizchi, Mahmoud

    2015-01-06

    Ion mobility spectrometry (IMS) is a fast and sensitive analytical method which operates at the atmospheric pressure. To enhance the capability of IMS for the analysis of mixtures, it is often used with preseparation techniques, such as GC or HPLC. Here, we report for the first time the coupling of the thin-layer chromatography and IMS. A variety of coupling schemes were tried that included direct electrospray from the TLC strip tip, indirect electrospray from a needle connected to the TLC strip, introducing the moving solvent into the injection port, and, the simplest way, offline introduction of scratched or cut pieces of strips into the IMS injection port. In this study a special solvent tank was designed and the TLC strip was mounted horizontally where the solvent would flow down. A very small funnel right below the TLC tip collected the solvent and transferred it to a needle via a capillary tubing. Using the TLC-ESI-IMS technique, acceptable separations were achieved for two component mixtures of morphine-papaverine and acridine-papaverine. A special injection port was designed to host the pieces cut off the TLC. The method was successfully used to identify each spot on the TLC by IMS in a few seconds.

  19. Ion-exchange chromatography for the characterization of biopharmaceuticals.

    Science.gov (United States)

    Fekete, Szabolcs; Beck, Alain; Veuthey, Jean-Luc; Guillarme, Davy

    2015-09-10

    Ion-exchange chromatography (IEX) is a historical technique widely used for the detailed characterization of therapeutic proteins and can be considered as a reference and powerful technique for the qualitative and quantitative evaluation of charge heterogeneity. The goal of this review is to provide an overview of theoretical and practical aspects of modern IEX applied for the characterization of therapeutic proteins including monoclonal antibodies (Mabs) and antibody drug conjugates (ADCs). The section on method development describes how to select a suitable stationary phase chemistry and dimensions, the mobile phase conditions (pH, nature and concentration of salt), as well as the temperature and flow rate, considering proteins isoelectric point (pI). In addition, both salt-gradient and pH-gradient approaches were critically reviewed and benefits as well as limitations of these two strategies were provided. Finally, several applications, mostly from pharmaceutical industries, illustrate the potential of IEX for the characterization of charge variants of various types of biopharmaceutical products. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Probing the kinetic performance limits for ion chromatography. I. Isocratic conditions for small ions.

    Science.gov (United States)

    Causon, Tim J; Hilder, Emily F; Shellie, Robert A; Haddad, Paul R

    2010-07-30

    The first use of the kinetic plot method to characterise the performance of ion-exchange columns for separations of small inorganic anions is reported. The influence of analyte type (mono- and divalent), particle size (5 and 9microm), temperature (30 and 60 degrees C) and maximum pressure drop upon theoretical extrapolations was investigated using data collected from anion-exchange polymeric particulate columns. The quality of extrapolations was found to depend upon the choice of analyte, but could be verified by coupling a series of columns to demonstrate some practical solutions for ion chromatography separations requiring relatively high efficiency. Separations of small anions yielding 25-40,000 theoretical plates using five serially connected columns (9microm particles) were obtained and yielded deviations of 10min).

  1. [Rapid determination of volatile organic compounds in workplace air by protable gas chromatography-mass spectrometer].

    Science.gov (United States)

    Zhu, H B; Su, C J; Tang, H F; Ruan, Z; Liu, D H; Wang, H; Qian, Y L

    2017-10-20

    Objective: To establish a method for rapid determination of 47 volatile organic compounds in the air of workplace using portable gas chromatography-mass spectrometer(GC-MS). Methods: The mixed standard gas with different concentration levels was made by using the static gas distribution method with the high purity nitrogen as dilution gas. The samples were injected into the GC-MS by a hand-held probe. Retention time and characteristic ion were used for qualitative analysis,and the internal standard method was usd for quantitation. Results: The 47 poisonous substances were separated and determined well. The linear range of this method was 0.2-16.0 mg/m(3),and the relative standard deviation of 45 volatile ovganic compounds was 3.8%-15.8%. The average recovery was 79.3%-119.0%. Conclusion: The method is simple,accurate,sensitive,has good separation effect,short analysis period, can be used for qualitative and quantitative analysis of volatile organic compounds in the workplace, and also supports the rapid identification and detection of occupational hazards.

  2. Identification and quantification of glucosinolates in rapeseed using liquid chromatography-ion trap mass spectrometry.

    Science.gov (United States)

    Millán, Silvia; Sampedro, M Carmen; Gallejones, Patricia; Castellón, Ander; Ibargoitia, Maria L; Goicolea, M Aranzazu; Barrio, Ramón J

    2009-07-01

    A rapid and sensitive method for the speciation and quantification of glucosinolates in rapeseed is described. The method combines liquid chromatography (LC) with ion trap mass spectrometry (ITMS) detection. Electrospray ionization (ESI) has been chosen as the ionization technique for the on-line coupling of LC with ITMS. Glucosinolates are extracted from different rapeseeds with MeOH and the extracts are cleaned-up by solid phase extraction with Florisil cartridges. Aqueous extracts are injected into LC system coupled to an ITMS, leading to accurately quantify eight of the most important glucosinolates in rapeseed, by MS2 mode and confirming their structure by MS3 acquisition. All the glucosinolates found in rapeseeds provide good signals corresponding to the deprotonated precursor ion [M-H]-. The method is reliable and reproducible, and detection limits range from 0.5 nmol g(-1) to 3.7 nmol g(-1) when 200 mg of dried seeds of certified reference material are analyzed. Within-day and between-day RSD percentages range between 2.4-14.1% and 3.9-16.9%, respectively. The LC-ESI-ITMS-MS method described here allows for a rapid assessment of these metabolites in rapeseed without a desulfatation step. The overall process has been successfully applied to identify and quantify glucosinolates in rapeseed samples.

  3. Superheated water ion-exchange chromatography: an experimental approach for interpretation of separation selectivity in ion-exchange processes.

    Science.gov (United States)

    Shibukawa, Masami; Shimasaki, Tomomi; Saito, Shingo; Yarita, Takashi

    2009-10-01

    Cation-exchange selectivity for alkali and alkaline-earth metal ions and tetraalkylammonium ions on a strongly acidic sulfonic acid cation-exchange resin has been investigated in the temperature range of 40-175 degrees C using superheated water chromatography. Dependence of the distribution coefficient (ln KD) on the reciprocal of temperature (1/T) is not linear for most of the ions studied, and the selectivity coefficient for a pair of alkali metal ions or that of alkaline-earth metal ions approaches unity as temperature increases. On the other hand, the retention order of tetraalkylammonium ions is reversed at 160 degrees C or above when eluted with Na2SO4 aqueous solution and the larger ions are eluted faster than the smaller ones contrary to the retention order obtained at ambient temperature. The change in ion-exchange selectivity with temperature observed with superheated water chromatography has been discussed on the basis of the effect of temperature on hydration of the ions and specific adsorption or distribution of ionic species between the external solution and ion-exchange resin. In superheated water, the electrostatic interaction or association of the ions with the fixed ion becomes a predominant mechanism resulting in different separation selectivity from that obtained at ambient temperature.

  4. Chromatography.

    Science.gov (United States)

    Brantley, L. Reed, Sr.; Demanche, Edna L.; Klemm, E. Barbara; Kyselka, Will; Phillips, Edwin A.; Pottenger, Francis M.; Yamamoto, Karen N.; Young, Donald B.

    This booklet presents some activities on chromatography. Directions for preparing leaf pigment extracts using alcohol are given, and paper chromatography and thin-layer chromatography are described as modifications of the basic principles of chromatography. (KHR)

  5. Rapid inorganic ion analysis using quantitative microchip capillary electrophoresis

    NARCIS (Netherlands)

    Vrouwe, E.X.; Lüttge, Regina; Olthuis, Wouter; van den Berg, Albert

    2006-01-01

    Rapid quantitative microchip capillary electrophoresis (CE) for online monitoring of drinking water enabling inorganic ion separation in less than 15s is presented. Comparing cationic and anionic standards at different concentrations the analysis of cationic species resulted in non-linear

  6. Ion Exchange Chromatography-Indirect Ultraviolet Detection for Separation and Determination of Morpholinium Ionic Liquid Cations.

    Science.gov (United States)

    Zhang, Yu; Ma, Yajie; Yu, Hong; Liu, Yongqiang

    2017-01-01

    A rapid analytical method of ion exchange chromatography with indirect ultraviolet detection was developed to determine morpholinium ionic liquid (IL) cations, i.e. N-methyl-N-ethyl morpholinium cation ([MEMo]+) and N-methyl-N-propyl morpholinium cation ([MPMo]+). Chromatographic separation of morpholinium cations was performed on a sulfonic acid base cation exchange column using imidazolium ionic liquid-organic solvent as mobile phase. The effects of chromatographic columns, ultraviolet absorption reagents, imidazolium ILs, detection wavelength, organic solvents, pH values of the mobile phase and column temperature on the retention of morpholinium cations were investigated. The retention times of the cations were clearly decreased by the increase of the alkyl substituent length on imidazolium cation or with the increase of the concentration of 1-ethyl-3-methyl imidazolium tetrafluoroborate. The molecular structure of the anion of imidazolium IL which has UV absorption has influence on determination of the analytes. Under the optimal conditions, the detection limits (signal-to-noise ratio, S/N = 3) were 0.29 and 0.44 mg L-1 The method has been successfully applied to the determination of two ILs synthesized by chemistry laboratory. The method uses the liquid chromatography system, which is widely available in general laboratories, and the simple composition of mobile phase, thus make the quantitative analysis of no UV absorption morpholinium cations possible. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  7. Matrix influences on the determination of common ions by using ion chromatography part 1--determination of inorganic anions.

    Science.gov (United States)

    Michalski, Rajmund; Lyko, Aleksandra; Kurzyca, Iwona

    2012-07-01

    Ion chromatography is the most popular instrumental analytical method used for the determination of anions and cations in water and wastewater. Isocratic ion chromatography with suppressed conductivity detection is frequently used in laboratories carrying out routine analyses of inorganic anions. The paper presents the results of the research into the influence of selected inorganic anions dominant in environmental samples (Cl(-), NO(3)(-), SO(4)(2-)) on the possibility of simultaneous determination of F(-), Cl(-), NO(2)(-), NO(3)(-), PO(4)(3-) and SO(4)(2-) with the application of this most popular ion chromatography type in standard separation conditions. Four Dionex and four Metrohm anion-exchange columns were tested in standard separation conditions recommended by their manufacturers with both standard solutions and environmental samples with complex matrix.

  8. Lanthanide luminescence quenching as a detection method in ion chromatography. Chromate in surface and drinking water

    NARCIS (Netherlands)

    SCHREURS, M; Somsen, G. W.; Gooijer, C.; Velthorst, N. H.; Frei, R W

    1989-01-01

    Dynamic quenching of Eu(IIl) and TB(III) luminescence by inorganic anions as a detection method in ion chromatography was investigated. To obtain a high luminescence intensity lanthanide(III) complexes are formed with ligands which make indirect excitation of the ions possible. Only a few anions

  9. Rapid analysis of perchlorate, chlorate and bromate ions in concentrated sodium hypochlorite solutions.

    Science.gov (United States)

    Pisarenko, Aleksey N; Stanford, Benjamin D; Quiñones, Oscar; Pacey, Gilbert E; Gordon, Gilbert; Snyder, Shane A

    2010-02-05

    A sensitive, rapid, and rugged liquid chromatography with tandem mass spectrometry (LC-MS/MS) method for measuring concentrations of perchlorate, chlorate, and bromate ions in concentrated sodium hypochlorite solutions is presented. The LC-MS/MS method offers a practical quantitation limit (PQL) of 0.05 microg L(-1) for ClO(4)(-), 0.2 microg L(-1) for BrO(3)(-), and 0.7 microg L(-1) for ClO(3)(-) and a sample analysis time of only 10 min. Additionally, an iodometric titration technique was compared with the LC-MS/MS method for measurement of chlorate ion at high concentration. The LC-MS/MS method was the most reproducible for chlorate concentrations below 0.025 M while the iodometric titration method employed was the most reproducible above 0.025 M. By using both methods, concentrations of chlorate can be measured over a wide range, from 0.7 microg L(-1) to 210 g L(-1) in hypochlorite ion solutions. Seven quenching agents were also evaluated for their ability to neutralize hypochlorite ion, thereby stopping formation of perchlorate ion in solution, without adversely impacting the other oxyhalide ions. Malonic acid was chosen as the quenching agent of choice, meeting all evaluation criteria outlined in this manuscript. Copyright 2009 Elsevier B.V. All rights reserved.

  10. Ion-exchange chromatography separation applied to mineral recycle in closed systems

    Science.gov (United States)

    Ballou, E.; Spitze, L. A.; Wong, F. W.; Wydeven, T.; Johnson, C. C.

    1981-01-01

    As part of the controlled ecological life support system (CELSS) program, a study is being made of mineral separation on ion-exchange columns. The purpose of the mineral separation step is to allow minerals to be recycled from the oxidized waste products of plants, man, and animals for hydroponic food production. In the CELSS application, relatively large quantities of minerals in a broad concentration range must be recovered by the desired system, rather than the trace quantities and very low concentrations treated in analytical applications of ion-exchange chromatography. Experiments have been carried out to assess the parameters pertinent to the scale-up of ion-exchange chromatography and to determine feasibility. Preliminary conclusions are that the column scale-up is in a reasonable size range for the CELSS application. The recycling of a suitable eluent, however, remains a major challenge to the suitability of using ion exchange chromatography in closed systems.

  11. Study of chromatographic characteristics of inorganic analytes in biopartitioning micellar chromatography with ion-pair additives.

    Science.gov (United States)

    Rukhadze, Marina; Lominadze, Nino; Akhalkatsi, Levan; Gvaramia, Manuchar

    2010-12-01

    The chromatographic behavior of model ions of biomedical and environmental significance was investigated by using nonionic micellar mobile phases modified with ion-pair additives. The influence of concentrations of polyoxyethylene (23) lauryl ether and ornithine hydrochloride in the mobile phase on the retention factors of chromium (III), chromium (VI), iodide and bromide ions was studied. The possible mechanisms of retention of the mentioned ions in biopartitioning micellar chromatography with zwitter ion-pair additives were proposed. Copyright © 2010 John Wiley & Sons, Ltd.

  12. [Rapid analysis on phenolic compounds in Rheum palmatum based on UPLC-Q-TOF/MSE combined with diagnostic ions filter].

    Science.gov (United States)

    Wang, Qing; Lu, Zhi-Wei; Liu, Yue-Hong; Wang, Ming-Ling; Fu, Shuang; Zhang, Qing-Qing; Zhao, Hui-Zhen; Zhang, Zhi-Xin; Xie, Zi-Ye; Huang, Zheng-Hai; Yu, Hong-Hong; Zhou, Wen-Juan; Gao, Xiao-Yan

    2017-05-01

    Diagnostic ions filter method was used to rapidly detect and identify the phenolic compounds in Rheum palmatum based on ultra performance liquid chromatography coupled with quadrupole time-of-flight mass spectrometry (UPLC-Q-TOF/MSE). The representative authentic standards of phenolic compounds, including gallic acid, (+)-catechin, (-)-epicatechin, (-)-epicatechin-3-O-gallate and procyanidin B2, were subjected to analysis by UPLC-Q-TOF/MSE system with negative ion mode. Fragmentation patterns of each standard were summarized based on assigned fragment ions. The prominent product ions were selected as diagnostic ions. Subsequently, diagnostic ions filter was employed to rapidly recognize analogous skeletons. Combined with retention time, accurate mass, characteristic fragments and previous literature data, the structures of the filtered compounds were identified or tentatively characterized. A total 63 phenolic compounds (36 phenolic acid derivatives, 8 flavonoid derivatives and 19 tennis derivatives) in R. palmatum were identified, including 6 potential new compounds. The method of diagnostic ions filter could rapidly detect and identify phenolic compounds in R. palmatum This study provides a method for rapid detection of phenolic compounds in R. palmatum and is expected to complete the material basis of rhubarb. Copyright© by the Chinese Pharmaceutical Association.

  13. Selective retention of basic compounds by metal aquo-ion affinity chromatography.

    Science.gov (United States)

    Asakawa, Yoshiki; Yamamoto, Eiichi; Asakawa, Naoki

    2014-10-01

    A novel metal aquo-ion affinity chromatography has been developed for the analysis of basic compounds using heat-treated silica gel containing hydrated metal cations (metal aquo-ions) as the packing material. The packing materials of the metal aquo-ion affinity chromatography were prepared by the immobilization of a single metal component such as Fe(III), Al(III), Ag(I), and Ni(II) on silica gel followed by extensive heat treatment. The immobilized metals form aquo-ions to present cation-exchange ability for basic analytes and the cation-exchange ability for basic analytes depends on pKa of the immobilized metal species. In the present study, to evaluate the retention characteristics of metal aquo-ion affinity chromatography, the on-line solid-phase extraction of drugs was investigated. Obtained data clearly evidence the selective retention capability of metal aquo-ion affinity chromatography for basic analytes with sufficient capacity. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Quantitation of sulfate and thiosulfate in clinical samples by ion chromatography.

    Science.gov (United States)

    Cole, D E; Evrovski, J

    1997-11-21

    For assay of serum sulfate, quantitation by ion conductimetry after separation by anion-exchange chromatography is the method of choice. In comparison to classical barium precipitation methods, chromatographic methods demonstrate increased precision, specificity and sensitivity, and they may be superior to spectrophotometric methods that rely on organic cation precipitation of sulfate. The increased sensitivity and specificity, as well as the inherent capacity of chromatographic methods for simultaneous determination of other anions, has led to its increasing use in the determination of excreted sulfate in clinical profiles of urinary anion composition. Ion chromatography can also be used to quantitate free sulfate in other clinical samples, including cerebrospinal fluid, sweat, saliva, breast milk and human tissues. Finally, ion chromatography shows promise as a more precise and sensitive method for measurement of total acid-labile sulfoesters and thiosulfate.

  15. Separation of silver ions and starch modified silver nanoparticles using high performance liquid chromatography with ultraviolet and inductively coupled mass spectrometric detection

    Science.gov (United States)

    Hanley, Traci A.; Saadawi, Ryan; Zhang, Peng; Caruso, Joseph A.; Landero-Figueroa, Julio

    2014-10-01

    The production of commercially available products marketed to contain silver nanoparticles is rapidly increasing. Species-specific toxicity is a phenomenon associated with many elements, including silver, making it imperative to develop a method to identify and quantify the various forms of silver (namely, silver ions vs. silver nanoparticles) possibly present in these products. In this study a method was developed using high performance liquid chromatography (HPLC) with ultraviolet (UV-VIS) and inductively coupled mass spectrometric (ICP-MS) detection to separate starch stabilized silver nanoparticles (AgNPs) and silver ions (Ag+) by cation exchange chromatography with 0.5 M nitric acid mobile phase. The silver nanoparticles and ions were baseline resolved with an ICP-MS response linear over four orders of magnitude, 0.04 mg kg- 1 detection limit, and 90% chromatographic recovery for silver solutions containing ions and starch stabilized silver nanoparticles smaller than 100 nm.

  16. High-Performance Liquid Chromatography of Nucleobases, Nucleosides and Nucleotides : II. Mobile Phase Composition for the Separation of Charged Solutes by Ion-Exchange Chromatography

    NARCIS (Netherlands)

    Haastert, Peter J.M. van

    1981-01-01

    The polarity, pH, ion concentration and polarity of the buffer ions of the mobile phase were modified systematically in order to find optimal conditions for the separation of nucleobases, nucleosides and nucleotides by ion-exchange chromatography. The effects of these mobile phase parameters on the

  17. The synthesis and study of monolithic capillary columns for ion chromatography of anions

    Science.gov (United States)

    Kurganov, A. A.; Korolev, A. A.; Viktorova, E. N.; Kanat'eva, A. Yu.

    2009-02-01

    The physicochemical and chromatographic parameters of ion-exchange monolithic matrices and capillary columns on their basis were measured. A method was suggested for producing high-efficiency ionexchange monolithic capillary columns with the monolith structure optimized for efficient selective separation of anions in ion chromatography. The influence of the conditions of synthesis of monoliths on their porosity, permeability, the structure of the monolith layer, and the impedance of monolithic columns on their basis was investigated.

  18. Focused ion beam lithography for rapid prototyping of metallic films

    Energy Technology Data Exchange (ETDEWEB)

    Osswald, Patrick; Kiermaier, Josef; Becherer, Markus; Schmitt-Landsiedel, Doris [Lehrstuhl fuer Technische Elektronik, TU Muenchen, Munich (Germany)

    2010-07-01

    We present FIB-lithography methods for rapid and cost-effective prototyping of metal structures covering the deep-submicron- to the millimeter-range in a single lithography cycle. Focused ion beam (FIB) systems are widely used in semiconductor industry and research facilities for both analytical testing and prototyping. A typical application is to apply electrical contact to micron-sized sensors/particles by FIB induced metal deposition. However, as for E-beam lithography, patterning times for large area bonding pads are unacceptably long, resulting in cost-intensive prototyping. In this work, we optimized FIB lithography processing for negative and positive imaging mode to form metallic structures for large-areas down do the sub-100 nm range. For negative lithography features are defined by implanting Ga{sup +}-ions into a commercial photo resist, without affecting the underlying structures by impinging ions. The structures are highly suitable for following lift-off processing due to the undercut of the resist.Metallic feature size of down to 150 nm are achievable. For positive lithography a PMMA resist is exposed in FIB irradiation. Due to the very low dose (3.10{sup 12} ions/cm{sup 2}) the writing time for an e.g. 100 {mu}m x 100 {mu}m square is approx. 15 seconds. The developed resist is used for subsequent wet chemical etching, obtaining a 100 nm resolution in metal layers.

  19. Off-line coupling of multidimensional immunoaffinity chromatography and ion mobility spectrometry: A promising partnership.

    Science.gov (United States)

    Armenta, Sergio; de la Guardia, Miguel; Abad-Fuentes, Antonio; Abad-Somovilla, Antonio; Esteve-Turrillas, Francesc A

    2015-12-24

    The extreme specificity of immunoaffinity chromatography (IAC) columns coupled to the high sensitivity of ion mobility spectrometry (IMS) measurements makes this combination really useful for rapid, selective, and sensitive determination of a high variety of analytes in different samples. The capabilities of the IAC-IMS coupling have been highlighted under three different scenarios: (i) multiclass residue analysis using a single IAC column, (ii) multiclass residue analysis using stacked IAC columns, and (iii) isomer analysis. In the first case, the determination of three strobilurin fungicides - azoxystrobin, picoxystrobin, and pyraclostrobin - in water and strawberry juice was considered, obtaining limits of quantification (LOQs) from 11 to 63μgL(-1). Recoveries from 96 to 106% for water, and from 67 to 104% for strawberry juice were obtained. In the second case, anilinopyrimidine compounds, including two analytes with similar drift time, were selectively retained in different IAC columns and analyzed after independent elution in commercial wine samples by IMS. LOQ values of 16, 14 and 12μgL(-1) were obtained for pyrimethanil, mepanipyrim, and cyprodinil, respectively. The obtained recoveries for wine samples spiked with 25 and 100μgL(-1) were from 82 to 123%. Additionally, the stacked IAC columns concept was applied to the separation of Z and E isomers of azoxystrobin that were selectively retained in specific IAC columns and quantified by IMS. Recoveries between 91 and 94% were obtained for both isomers in water samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Graphene-coated polymeric anion exchangers for ion chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Kai; Cao, Minyi; Lou, Chaoyan [Department of Chemistry, Xixi Campus, Zhejiang University, Hangzhou 310028 (China); Wu, Shuchao, E-mail: wushch2002@163.com [Zhejiang Institute of Geology and Mineral Resources, Hangzhou 310007 (China); Zhang, Peimin [Department of Chemistry, Xixi Campus, Zhejiang University, Hangzhou 310028 (China); Zhi, Mingyu [Hangzhou Vocational & Technical College, Hangzhou, 310018 (China); Zhu, Yan, E-mail: zhuyan@zju.edu.cn [Department of Chemistry, Xixi Campus, Zhejiang University, Hangzhou 310028 (China)

    2017-06-01

    Carbonaceous stationary phases have gained much attention for their peculiar selectivity and robustness. Herein we report the fabrication and application of a graphene-coated polymeric stationary phase for anion exchange chromatography. The graphene-coated particles were fabricated by a facile evaporation-reduction method. These hydrophilic particles were proven appropriate substrates for grafting of hyperbranched condensation polymers (HBCPs) to make pellicular anion exchangers. The new phase was characterized by zeta potentials, Fourier transform infrared spectroscopy, thermogravimetry and scanning electron microscope. Frontal displacement chromatography showed that the capacities of the anion exchangers were tuned by both graphene amount and HBCPs layer count. The chromatographic performance of graphene-coated anion exchangers was demonstrated with separation of inorganic anions, organic acids, carbohydrates and amino acids. Good reproducibility was obtained by consecutive injections, indicating high chemical stability of the coating. - Highlights: • Graphene-coated polymeric particles were fabricated by a facile method. • Hyperbranched condensation polymers (HBCPs) were grafted from graphene-coated particles to make anion exchangers. • Graphene amount and HBCPs layer count had significant effects on the anion exchange capacities. • Separation of diverse anionic analytes on the anion exchangers was demonstrated. • The prepared anion exchangers exhibited high stability.

  1. Weeping Glass: The Identification of Ionic Species on the Surface of Vessel Glass Using Ion Chromatography

    NARCIS (Netherlands)

    Verhaar, G.; van Bommel, M.R.; Tennent, N.H.; Roemich, H.; Fair, L.

    2016-01-01

    Aqueous films on the surface of unstable vessel glass were analysed. Five cation and eight anion species from eleven glass items in the Rijksmuseum, Amsterdam, the Hamburg Museum and the Corning Museum of Glass have been quantified by ion chromatography. Sodium, potassium, magnesium and calcium

  2. Nitrate and nitrite content in bottled beverages by ion-pair high-performance liquid chromatography.

    Science.gov (United States)

    Song, Yang; Deng, Gui-Fang; Xu, Xiang-Rong; Chen, Yong-Hong; Chen, Feng; Li, Hua-Bin

    2013-01-01

    Nitrate and nitrite levels in six types of beverages--total of 292 individual samples from 73 brands (four bottles each)--from Guangzhou city in China were evaluated by ion-pair high-performance liquid chromatography. All samples contained nitrate. Nitrate and nitrite ranges were 0.43-46.08 and beverages.

  3. Rapid detection of malto-oligosaccharide-forming bacterial amylases by high performance anion-exchange chromatography

    DEFF Research Database (Denmark)

    Duedahl-Olesen, Lene; Larsen, K. L.; Zimmermann, W.

    2000-01-01

    High performance anion-exchange chromatography with pulsed amperometric detection was applied for the rapid analysis of malto-oligosaccharides formed by extracellular enzyme preparations from 49 starch-degrading bacterial strains isolated from soil and compost samples. Malto-oligosaccharide-formi......High performance anion-exchange chromatography with pulsed amperometric detection was applied for the rapid analysis of malto-oligosaccharides formed by extracellular enzyme preparations from 49 starch-degrading bacterial strains isolated from soil and compost samples. Malto......-oligosaccharide-forming amylases, indicated by a predominant formation of maltohexaose from starch, were produced by enzyme preparations from four of the isolates growing at pH 7.0 and 10....

  4. Comparison of different transition metal ions for immobilized metal affinity chromatography of selenoprotein P from human plasma

    DEFF Research Database (Denmark)

    Sidenius, U; Farver, O; Jøns, O

    1999-01-01

    Cu2+, Ni2+, Zn2+, Co2+ and Cd2+ were evaluated in metal ion affinity chromatography for enrichment of selenoprotein P, and immobilized Co2+ affinity chromatography was found to be the most selective chromatographic method. The chromatography was performed by fast protein liquid chromatography and....... The purity of the protein was determined by SDS-PAGE and by sequencing from polyvinylidene difluoride blots of SDS-PAGE gels....

  5. Screening of drugs and toxic compounds with liquid chromatography-linear ion trap tandem mass spectrometry.

    Science.gov (United States)

    Sauvage, François-Ludovic; Saint-Marcoux, Franck; Duretz, Bénédicte; Deporte, Didier; Lachatre, Gérard; Marquet, Pierre

    2006-09-01

    In clinical and forensic toxicology, general unknown screening is used to detect and identify exogenous compounds. In this study, we aimed to develop a comprehensive general unknown screening method based on liquid chromatography coupled with a hybrid triple-quadrupole linear ion trap mass spectrometer. After solid-phase extraction, separation was performed using gradient reversed-phase chromatography. The mass spectrometer was operated in the information-dependent acquisition mode, switching between a survey scan acquired in the Enhanced Mass Spectrometry mode with dynamic subtraction of background noise and a dependent scan obtained in the enhanced product ion scan mode. The complete cycle time was 1.36 s. A library of 1000 enhanced product ion-tandem mass spectrometry spectra in positive mode and 250 in negative mode, generated using 3 alternated collision tensions during each scan, was created by injecting pure solutions of drugs and toxic compounds. Comparison with HPLC-diode array detection and gas chromatography-mass spectrometry for the analysis of 36 clinical samples showed that linear ion trap tandem mass spectrometry could identify most of the compounds (94% of the total). Some compounds were detected only by 1 of the other 2 techniques. Specific clinical cases highlighted the advantages and limitations of the method. A unique combination of new operating modes provided by hybrid triple-quadrupole linear ion trap mass spectrometers and new software features allowed development of a comprehensive and efficient method for the general unknown screening of drugs and toxic compounds in blood or urine.

  6. Fear and loathing at a combined cycle power plant - ion chromatography in a box

    Energy Technology Data Exchange (ETDEWEB)

    Newton, B.; Doyle, M. [Dionex Corporation, Sunnyvale, CA (United States); Carvalho, L.; Scarth, I. [GE Water and Process Technologies, Mississauga, ON (Canada); Lindau, P.

    2005-06-01

    The use of ion chromatography for monitoring corrosive ions in water has been implemented at several new combined cycle gas-fired power plants. Due to stringent requirements for clean water to prevent corrosion and plugging of turbine components, this methodology is predicted to have a significant impact in extending useful operating lifetimes and to measurably increase the availability of components in contact with water. Ion chromatography, due to its ability to identify individual anion and cation species, to achieve parts-per-trillion detection limits, and to operate on-line, has played a central role in the effectiveness of these water chemistry monitoring programs. Combined cycle power plants are faced with tough choices for water monitoring. The lack of trained chemists to run low level analyses results in uncertainty as to the quality of the water used for steam going to the turbine and in some cases to the generator. This paper presents a report on a recent study of a low cost, hands-off ion chromatography solution to provide on-line monitoring at the water panel for chloride and sulfate ions at 1 part per billion or below. (orig.)

  7. Ion-pair, anion-exchange and ligand-exchange high-performance liquid chromatography of tenuazonic acid and 3-acetyl 5-substituted pyrrolidine-2,4-diones.

    Science.gov (United States)

    Lebrun, M H; Gaudemer, F; Boutar, M; Nicolas, L; Gaudemer, A

    1989-03-03

    The ion-pair, ligand-exchange and anion-exchange chromatography of the fungal metabolic tenuazonic acid (TA) and its related 3-acetyl 5-substituted pyrrolidine-2,4-diones were studied. Ion-pair chromatography was performed on a C18 column with a mobile phase composed of cetrimide, phosphate buffer in water-methanol and a metal complexant (ethylenediamine) to improve the peak sharpness. Addition of the same metal complexant to the mobile phase of the anion-exchange chromatographic system also improved its efficiency. TA and its 5-substituted analogues derived from valine and leucine were separated with the ion-pair and anion-exchange chromatographic systems. With ligand-exchange chromatography, TA could only be separated from its valine analogue. These chromatographic systems were used for the detection of TA in the culture filtrates of the fungus Pyricularia oryzae and in infected rice leaves. Deproteinated culture filtrates could be rapidly analysed for their TA content by anion-exchange chromatography. However, this system was not suitable for the detection of TA in the infected rice leaf as interfering compounds were coeluted with TA. Ion-pair and ligand-exchange chromatographic systems allowed the efficient quantification of TA in infected leaves.

  8. Simple coupled ultrahigh performance liquid chromatography and ion chromatography technique for simultaneous determination of folic acid and inorganic anions in folic acid tablets.

    Science.gov (United States)

    Wang, Fenglian; Cao, Minyi; Wang, Nani; Muhammad, Nadeem; Wu, Shuchao; Zhu, Yan

    2018-01-15

    Folic acid plays a significant role during periods of rapid cells division and growth. Pregnant women require folic acid daily, either from dietary supplements or folic acid tablets in order to prevent fetal neural tube defects. In this work, a simple coupled ultrahigh performance liquid chromatography and ion chromatography technique was developed for simultaneous determination of folic acid and inorganic anions in folic acid tablets. A reversed-phase C18 column was used as the pretreatment column for on-line separating inorganic anions from organics. Inorganic anions were concentrated in the concentration column. Under the optimal chromatographic conditions, good sensitivity and linear calibration-curves (r≥0.9992) were obtained. Low detection limits were obtained in the range of 0.0032-0.40mgL-1 for all analytes. Repeatability results were satisfactory with relative standard deviations less than 1.50% (n=5). The developed method was utilized to analyze spiked folic acid tablet samples with good measured recoveries (92.4-107.4%). Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Identification of chemical components in Baidianling Capsule based on gas chromatography-mass spectrometry and high-performance liquid chromatography combined with Fourier transform ion cyclotron resonance mass spectrometry.

    Science.gov (United States)

    Wu, Wenying; Chen, Yu; Wang, Binjie; Sun, Xiaoyang; Guo, Ping; Chen, Xiaohui

    2017-08-01

    Baidianling Capsule, which is made from 16 Chinese herbs, has been widely used for treating vitiligo clinically. In this study, the sensitive and rapid method has been developed for the analysis of chemical components in Baidianling Capsule by gas chromatography-mass spectrometry in combination with retention indices and high-performance liquid chromatography combined with Fourier transform ion cyclotron resonance mass spectrometry. Firstly, a total of 110 potential volatile compounds obtained from different extraction procedures including alkanes, alkenes, alkynes, ketones, ethers, aldehydes, alcohols, phenols, organic acids, esters, furans, pyrrole, acid amides, heterocycles, and oxides were detected from Baidianling Capsule by gas chromatography-mass spectrometry, of which 75 were identified by mass spectrometry in combination with the retention index. Then, a total of 124 components were tentatively identified by high-performance liquid chromatography combined with Fourier transform ion cyclotron resonance mass spectrometry. Fifteen constituents from Baidianling Capsule were accurately identified by comparing the retention times with those of reference compounds, others were identified by comparing the retention times and mass spectrometry data, as well as retrieving the reference literature. This study provides a practical strategy for rapidly screening and identifying the multiple constituents of a complex traditional Chinese medicine. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Urinary thiosulfate determined by suppressed ion chromatography with conductimetric detection.

    Science.gov (United States)

    Cole, D E; Evrovski, J; Pirone, R

    1995-10-06

    Thiosulfate is a naturally occurring product of sulfur metabolism. Assays of urinary thiosulfate have been based on the reaction with cyanide to form thiocyanate. However, matrix interferences and background variation in endogenous thiocyanate excretion place serious constraints on this method for determination of physiological amounts of thiosulfate in urine. We describe a column-switching ion chromatographic separation for urinary thiosulfate that allows for sensitive and accurate detection by ion conductimetry. In 20 adult volunteers, we found a lower urinary thiosulfate (8.50 +/- 7.39 mumol/24 h, mean +/- S.D.) than others have described, although the upward skew of the results (median, 6.90; range, 0.84-32 mumol/24 h) was similar. However, we have not observed any of the interferences and the sensitivity of our technique (< 0.2 mumol/24 h) allows for detection of thiosulfate in all control samples. This sort of methodological improvement will be essential for any study of physiological thiosulfate metabolism.

  11. Optimization of anion separation by nonsuppressed ion chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Jenke, D.R.; Pagenkopf, G.K.

    1984-01-01

    The effect of eluent pH and eluent species concentration on the nonsuppressed ion chromatographic separation of anions has been studied. The retention times of Cl/sup -/, Br/sup -/, NO/sub 3//sup -/, SO/sub 4//sup 2 -/, and S/sub 2/O/sub 3//sup 2 -/ were determined over a large range of eluent compositions and the data were utilized to construct window diagrams. These window diagrams were used to optimize eluent composition for the separation of two or more analytes. In virtually every case resolution is limited by the separation of the NO/sub 3//sup -//Br/sup -/ pair. 10 references, 5 figures, 2 tables.

  12. Rapid Determination of L-carnitine in Infant and Toddler Formulas by Liquid Chromatography Tandem Mass Spectrometry.

    Science.gov (United States)

    Ahn, Jang-Hyuk; Kwak, Byung-Man; Park, Jung-Min; Kim, Na-Kyeoung; Kim, Jin-Man

    2014-01-01

    A rapid and simple analytical method for L-carnitine was developed for infant and toddler formulas by liquid chromatography tandem mass spectrometry (LC-MS/MS). A 0.3 g of infant formula and toddler formula sample was mixed in a 50 mL conical tube with 9 mL water and 1 mL 0.1 M hydrochloric acid (HCl) to chemical extraction. Then, chloroform was used for removing a lipid fraction. After centrifuged, L-carnitine was separated and quantified using LC-MS/MS with electrospray ionization (ESI) mode. The precursor ion for L-carnitine was m/z 162, and product ions were m/z 103 (quantitative) and m/z 85 (qualitative), respectively. The results for spiked recovery test were in the range of 93.18-95.64% and the result for certified reference material (SRM 1849a) was within the range of the certificated values. This method could be implemented in many laboratories that require time and labor saving.

  13. A two level hierarchical model of protein retention in ion exchange chromatography.

    Science.gov (United States)

    Salvalaglio, Matteo; Paloni, Matteo; Guelat, Bertrand; Morbidelli, Massimo; Cavallotti, Carlo

    2015-09-11

    Predicting protein retention in ion exchange chromatography (IEX) from first principles is a fascinating perspective. In this work a two level hierarchical modeling strategy is proposed in order to calculate protein retention factors. Model predictions are tested against experimental data measured for Lysozyme and Chymotrypsinogen A in IEX columns as a function of ionic strength and pH. At the highest level of accuracy Molecular Dynamics (MD) simulations in explicit water are used to determine the interaction free energy between each of the two proteins and the IEX stationary phase for a reference pH and ionic strength. At a lower level of accuracy a linear response model based on an implicit treatment of solvation and adopting a static protein structure is used to calculate interaction free energies for the full range of pHs and ionic strengths considered. A scaling coefficient, determined comparing MD and implicit solvent simulations, is then introduced in order to correct the linear response model for errors induced by the adoption of a static protein structure. The calculated free energies are then used to compute protein retention factors, which can be directly compared with experimental data. The possibility to introduce a third level of accuracy is explored testing the predictions of a semiempirical model. A quantitative agreement between the predicted and measured protein retention factors is obtained using the coupled MD-linear response models, supporting the reliability of the proposed approach. The model allows quantifying the electrostatic, van der Waals, and conformational contributions to the interaction free energies. A good agreement between experiments and model is obtained also using the semiempirical model that, although requiring parameterization over higher level models or experimental data, proves to be useful in order to rapidly determine protein retention factors across wide pH and ionic strength ranges as it is computationally inexpensive

  14. Boosting Sensitivity in Liquid Chromatography-Fourier Transform Ion Cyclotron Resonance-Tandem Mass Spectrometry for Product Ion Analysis of Monoterpene Indole Alkaloids

    National Research Council Canada - National Science Library

    Nakabayashi, Ryo; Tsugawa, Hiroshi; Kitajima, Mariko; Takayama, Hiromitsu; Saito, Kazuki

    2015-01-01

    .... However, the development of relevant analytical methods are less advanced. Here, we developed a method to boost sensitivity in liquid chromatography-Fourier transform ion cyclotron resonance-tandem mass spectrometry analysis...

  15. Rapid quantitative detection of glucose content in glucose injection by reaction headspace gas chromatography.

    Science.gov (United States)

    Xie, Wei-Qi; Gong, Yi-Xian; Yu, Kong-Xian

    2017-10-20

    This work investigates an automated technique for rapid detecting the glucose content in glucose injection by reaction headspace gas chromatography (HS-GC). This method is based on the oxidation reaction of glucose in glucose injection with potassium dichromate. The carbon dioxide (CO 2 ) formed from the oxidation reaction can be quantitatively detected by GC. The results show that the relative standard deviation (RSD) of the present method was within 2.91%, and the measured glucose contents in glucose injection closely match those quantified by the reference method (relative differences glucose content in glucose injection related applications. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Rapid determination of chlorobutanol in milk by glass capillary gas chromatography.

    Science.gov (United States)

    Van Rillaer, W G; Beernaert, H

    1984-06-01

    A rapid method for the determination of chlorobutanol(1,1,1-trichloro-2-methylpropan-2-ol) in milk is described. The method is based on a steam-distillation solvent-extraction technique and a quantitative determination of chlorobutanol by gas chromatography using a glass-capillary column coated with Carbowax 20M and 2,2,2-trichloroethanol as internal standard. The detection limit is 1 pg and recoveries of chlorobutanol are between 93 und 99%. Fifty-two milk samples have been analysed.

  17. A rapid quantitative method for the analysis of synthetic cannabinoids by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Freijo, Tom D; Harris, Steve E; Kala, Subbarao V

    2014-10-01

    Synthetic cannabinoids represent an emerging drug problem in the USA, as these compounds are constantly being modified and rapidly sold as soon as they become available. Laboratories around the world are constantly improving the analytical methods to detect and identify these newly available designer drugs. This study used a simple approach to detect and quantify a variety of synthetic cannabinoids (14 parent compounds and 15 metabolites including series XLR, AM, JWH, UR, RCS, PB, HU and AB-FUBINACA) using LC-MS-MS. Drug-free urine samples spiked with various synthetic cannabinoids and their metabolites were separated on a C18-Hypersil Gold column using an Agilent 1290 ultra-high performance liquid chromatography and detected by an AB Sciex API 4000 tandem mass spectrometer. Studies were carried out to determine limit of detection, limit of quantitation, upper limit of linearity, ion suppression, interference, precision and accuracy to validate the method. Urine samples from patients and known users were hydrolyzed with β-glucuronidase prior to the analysis by LC-MS-MS, and the data are presented. The method described here is rapid, highly sensitive and specific for the identification of a variety of synthetic cannabinoids. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  18. Development of a Rapid Microbore Metabolic Profiling Ultraperformance Liquid Chromatography-Mass Spectrometry Approach for High-Throughput Phenotyping Studies.

    Science.gov (United States)

    Gray, Nicola; Adesina-Georgiadis, Kyrillos; Chekmeneva, Elena; Plumb, Robert S; Wilson, Ian D; Nicholson, Jeremy K

    2016-06-07

    A rapid gradient microbore ultraperformance liquid chromatography-mass spectrometry (UPLC-MS) method has been developed to provide a high-throughput analytical platform for the metabolic phenotyping of urine from large sample cohorts. The rapid microbore metabolic profiling (RAMMP) approach was based on scaling a conventional reversed-phase UPLC-MS method for urinary profiling from 2.1 mm × 100 mm columns to 1 mm × 50 mm columns, increasing the linear velocity of the solvent, and decreasing the gradient time to provide an analysis time of 2.5 min/sample. Comparison showed that conventional UPLC-MS and rapid gradient approaches provided peak capacities of 150 and 50, respectively, with the conventional method detecting approximately 19 000 features compared to the ∼6 000 found using the rapid gradient method. Similar levels of repeatability were seen for both methods. Despite the reduced peak capacity and the reduction in ions detected, the RAMMP method was able to achieve similar levels of group discrimination as conventional UPLC-MS when applied to rat urine samples obtained from investigative studies on the effects of acute 2-bromophenol and chronic acetaminophen administration. When compared to a direct infusion MS method of similar analysis time the RAMMP method provided superior selectivity. The RAMMP approach provides a robust and sensitive method that is well suited to high-throughput metabonomic analysis of complex mixtures such as urine combined with a 5-fold reduction in analysis time compared with the conventional UPLC-MS method.

  19. Continuous Measurement of Macronutrient Ions in the Transpiration Stream of Intact Plants Using the Meadow Spittlebug Coupled with Ion Chromatography1

    Science.gov (United States)

    Malone, Michael; Herron, Michelle; Morales, M.-Angeles

    2002-01-01

    A method is described for continuous, nondestructive analysis of xylem-borne mineral nutrients in intact transpiring plants. The method uses the xylem-feeding insect the meadow spittlebug (Philaenus spumarius L. [Homoptera: Cercopidae]). This insect will feed from a wide range of plant species and organs. Insect excreta can be collected at all times of the day and night, and its mineral ion content can be analyzed rapidly, and without purification, by ion chromatography. The excreta will have a mineral content virtually identical to that of xylem sap. Cages suitable for containing the insects and collecting excreta from any desired location on plants in both laboratory and greenhouse are described. Even in the greenhouse, evaporation had only a minor effect on the sample ion content. Example results are presented which illustrate dynamics, over several days, in the xylem concentrations of sodium (Na+), potassium (K+), NH4+, magnesium (Mg2+), calcium (Ca2+), chloride (Cl−), NO3−, PO43−, and SO42−. These data were collected from young plants growing in pots of compost in the laboratory and from fully mature pepper (Capsicum annuum L. cv Bellboy) plants growing in hydroponics (rockwool) in the greenhouse. This method should facilitate studies of macronutrient uptake and transport in a range of plants and environments. PMID:12428008

  20. Rapid method for determination of carbonyl groups in lignin compounds by headspace gas chromatography.

    Science.gov (United States)

    Li, Jing; Hu, Hui-Chao; Chai, Xin-Sheng

    2015-07-24

    The paper reports on a novel method for rapid determination of carbonyl in lignins by headspace gas chromatography (HS-GC). The method involves the quantitative carbonyl reduction for aldehydes in 2min at room temperature or for acetones in 30min at 80°C by sodium borohydride solution in a closed headspace sample vial. After the reaction, the solution was acidified by injecting sulfuric acid solution and the hydrogen released to the headspace was determined by GC using thermal-conductivity detector. The results showed that with the addition of SiO2 powder, the reduction reaction of carbonyl groups can be greatly facilitated. The method has a good measurement precision (RSD<7.74%) and accuracy (relative error <10% compared with a reference method) in the carbonyl quantification. It is suitable to be used for rapid determination of carbonyl content in lignin and related materials. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Ion chromatography for the precise analysis of chloride and sodium in sweat for the diagnosis of cystic fibrosis

    NARCIS (Netherlands)

    Doorn, J.; Storteboom, T. T. R.; Mulder, A. M.; de Jong, W. H. A.; Rottier, B. L.; Kema, I. P.

    BACKGROUND: Measurement of chloride in sweat is an essential part of the diagnostic algorithm for cystic fibrosis. The lack in sensitivity and reproducibility of current methods led us to develop an ion chromatography/high-performance liquid chromatography (IC/HPLC) method, suitable for the analysis

  2. pH-gradient ion-exchange chromatography: An analytical tool for design and optimization of protein separations

    NARCIS (Netherlands)

    Ahamed, T.; Nfor, B.; Verhaert, P.; Deden, van G.; Wielen, van der L.

    2007-01-01

    This work demonstrates that a highly linear, controllable and wide-ranged pH-gradient can be generated through an ion-exchange chromatography (IEC) column. Such a pH-gradient anion-exchange chromatography was evaluated with 17 model proteins and found that acidic (pI <6) and basic (pI > 8)

  3. Characterization of poly(allylamine) as a polymeric ligand for ion-exchange protein chromatography.

    Science.gov (United States)

    Li, Ming; Li, Yanying; Yu, Linling; Sun, Yan

    2017-02-24

    This work reports poly(allylamine) (PAA), as a polymeric ion-exchange ligand for protein chromatography. Sepharose FF was modified with PAA, and six anion exchangers with ionic capacities (ICs) from 165 to 618mmol/L were prepared. Inverse size exclusion chromatography, adsorption equilibrium, uptake kinetics and column elution were performed. It was found that both the adsorption capacity and effective diffusivity maintained low values in the IC range of 165-373mmol/L, but they started to increase beyond 373mmol/L, and increased by 80% and 23 times, respectively, when the IC reached 618mmol/L. Interestingly, a drastic decrease of pore size was observed around the IC of 373mmol/L. The results suggest that the PAA chains played an important role in protein adsorption by altering the inner pore structure of the gels. It is considered that, PAA chains turn from inextensible states with multipoint-grafting on the pore surface at low coupling densities (IC373mmol/L). These characters of the grafted chains at higher IC values benefit in protein adsorption by three-dimensional binding and encouraged the happening of "chain delivery" of bound proteins on the chains. Besides, the ion exchangers showed favorable adsorption and uptake properties in a wide ionic strength range, 0-500mmol/L NaCl, indicating much better salt tolerance feature than the so-far reported ion exchangers. Moreover, a mild condition of pH 5.0 offered effective recovery of bound proteins in elution chromatography. The results indicate that the PAA-based anion exchanger of a high IC value is promising for high-capacity protein chromatography dealing with feedstock of a wide range of ionic strengths. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Isocratic Solid Phase Extraction-Liquid Chromatography (SPE-LC) Interfaced to High-Performance Tandem Mass Spectrometry for Rapid Protein Identification

    DEFF Research Database (Denmark)

    Hørning, Ole B; Kjeldsen, Frank; Theodorsen, Søren

    2008-01-01

    Reversed-phase liquid chromatography interfaced to electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) allows analysis of very complex peptide mixtures at great sensitivity, but it can be very time-consuming, typically using 60 min, or more, per sample analysis. We recently introduced...... the isocratic solid phase extraction-liquid chromatography (SPE-LC) technology for rapid separation ( approximately 8 min) of simple peptide samples. We now extend these studies to demonstrate the potential of SPE-LC separation in combination with a hybrid linear ion trap-Orbitrap tandem mass spectrometer...... for efficient analysis of peptide samples in proteomics research. The system performance of SPE-LC-MS/MS was evaluated in terms of sensitivity and efficiency for the analysis of tryptic peptide digests obtained from samples consisting of up to 12 standard proteins. The practical utility of the analytical setup...

  5. Anion content of snow by suppressed and non-suppressed ion chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Jenke, D.R.; Mitchell, P.K.; Pagenkopf, G.K.

    1983-11-01

    Both suppressed and non-suppressed ion chromatographic methods were employed in the analysis of snow sampled from the Rocky Mountains for Cl/sup -/, NO/sub 3//sup -/, and SO/sub 4//sup 2 -/. By suppressed ion chromatography the concentration of these anions was found to be less than 1 mg/liter. These concentrations are lower than what can be determined using commercially available non-suppressed systems. To overcome this problem, the samples may be preconcentrated or a larger sample used. Due to complications arising on using a larger sample, in the absence of preconcentration, each sample must be analyzed twice by the non-suppressed ion chromatographic procedure. By comparison, the suppressed procedure is a factor of 10 more sensitive than this non-suppressed procedure. Even so, the results obtained by each of these procedures are not significantly different one from the other. 14 references, 2 figures, 1 table.

  6. Mathematical modeling of salt-gradient ion-exchange simulated moving bed chromatography for protein separations.

    Science.gov (United States)

    Lu, Jian-Gang

    2004-12-01

    The salt-gradient operation mode used in ion-exchange simulated moving bed chromatography (SMBC) can improve the efficiency of protein separations. A detailed model that takes into account any kind of adsorption/ion-exchange equilibrium, salt gradient, size exclusion, mass transfer resistance, and port periodic switching mechanism, was developed to simulate the complex dynamics. The model predictions were verified by the experimental data on upward and downward gradients for protein separations reported in the literature. All design and operating parameters (number, configuration, length and diameter of columns, particle size, switching period, flow rates of feed, raffinate, desorbent and extract, protein concentrations in feed, different salt concentrations in desorbent and feed) can be chosen correctly by numerical simulation. This model can facilitate the design, operation, optimization, control and scale-up of salt-gradient ion-exchange SMBC for protein separations.

  7. [Determination of succinic acid in desvenlafaxine succinate by high performance ion-exclusion chromatography and high performance ion-exchange chromatography].

    Science.gov (United States)

    Zong, Yanping; Li, Jinghua; Sun, Wei; Liu, Guixia; Lu, Jinghua; Shan, Guangzhi

    2016-02-01

    New methods were developed for the determination of succinic acid in desvenlafaxine succinate (DVS) by high performance ion-exclusion chromatography (HPIEC) and high performance ion-exchange chromatography (HPIC). HPIEC and HPIC methods were used separately to determinate the succinic acid in DVS. With HPIEC, the sample was diluted with 2. 50 x 10(-3) mol/L sulfuric acid solution and filtrated by 0. 22 µm polyether sulfone filter membrane, and then analyzed by HPIEC directly without any further pretreatment. The analytical column was Phenomenex Rezex ROA-organic Acid H+(8%) (300 mmx7. 8 mm). The mobile phase was 2. 50x10(-3) mol/L sulfuric acid solution at the flow rate of 0. 5 mL/min. The column temperature was set at 40 °C, and the detection wavelength was 210 nm. The injection volume was 10 KL. The assay was quantified by external standard method. With HPIC, the sample was diluted with ultrapure water and filtrated by 0. 22 µm polyether sulfone filter membrane, and then analyzed by HPIC directly without any further pretreatment. The analytical column was Dionex IonPac AS11-HC (250 mm x 4 mm) with a guard column IonPacAG11-HC (50 mm x 4 mm). Isocratic KOH elute generator was used at the flow rate of 1. 0 mL/min. The detection was performed by a Dionex suppressed (DIONEX AERS 500 4-mm) conductivity detector. The injection volume was 10 µL. The content computation was performed with peak area external reference method. The results of HPIEC method for succinic acid were 28. 8%, 28. 9% and 28. 9%, while the results of HPIEC method were 28. 2%, 28. 6% and 28. 6%. The results of HPIEC and HPIC methods were not significantly different. The two methods can both be used to determine the contents of succinic acid in DVS. The surveillance analytical method should be chosen according to the situation.

  8. Indirect UV detection-ion-exclusion/cation-exchange chromatography of common inorganic ions with sulfosalicylic acid eluent.

    Science.gov (United States)

    Kozaki, Daisuke; Mori, Masanobu; Nakatani, Nobutake; Arai, Kaori; Masuno, Tomoe; Koseki, Masakazu; Itabashi, Hideyuki; Tanaka, Kazuhiko

    2013-01-01

    Herein, we describe indirect UV detection-ion-exclusion/cation-exchange chromatography (IEC/CEC) on a weakly acidic cation-exchange resin in the H(+)-form (TSKgel Super IC-A/C) using sulfosalicylic acid as the eluent. The goal of the study was to characterize the peaks detected by UV detector. The peak directions of analyte ions in UV at 315 nm were negative because the molar absorbance coefficients of analyte anions and cations were lower than that of the sulfosalicylic acid eluent. Good chromatographic resolution and high signal-to-noise ratios of analyte ions were obtained for the separations performed using 1.1 mM sulfosalicylic acid and 1.5 mM 18-crown-6 as the eluent. The relative standard deviations (RSDs) of the peak areas ranged from 0.6 to 4.9%. Lower detection limits of the analytes were achieved using indirect UV detection at 315 nm (0.23 - 0.98 μM) than those obtained with conductometric detection (CD) (0.61 - 2.1 μM) under the optimized elution conditions. The calibration curves were linear in the range from 0.01 to 1.0 mM except for Cl(-), which was from 0.02 to 2.0 mM. The present method was successfully applied to determine common inorganic ions in a pond water sample.

  9. Characterization of synthetic dyes by comprehensive two-dimensional liquid chromatography combining ion-exchange chromatography and fast ion-pair reversed-phase chromatography

    NARCIS (Netherlands)

    Pirok, B.W.J.; Knip, J.; van Bommel, M.R.; Schoenmakers, P.J.

    2016-01-01

    In the late 19th century, newly invented synthetic dyes rapidly replaced the natural dyes on the market. The characterization of mixtures of these so-called early synthetic dyes is complicated through the occurrence of many impurities and degradation products. Conventional one-dimensional liquid

  10. Ion exchange liquid chromatography method for the direct determination of small ribonucleic acids.

    Science.gov (United States)

    McGinnis, A Cary; Cummings, Brian S; Bartlett, Michael G

    2013-10-17

    Bioanalysis of siRNAs is challenging due to their size (5-14 kDa) and negative charge across the backbone, which complicates both sample preparation and chromatography. We present here a one step sample preparation combined with non-denaturing anion exchange chromatography with UV detection for the quantitation of siRNA and its chain shortened metabolites. The sample preparation uses a novel lysis buffer with proteinase K to effectively isolate siRNA from cells and formulated media with greater than 95% recovery. The ion exchange chromatography allows for a lower limit of quantitation of 6 ng mL(-1) in cells and media equivalent to 6 ng/200,000 cells. This method is applied to study the uptake of siRNA in prostate cancer cells and the disappearance in the media and siRNA metabolism. siRNA metabolites are identified by matching the retention time of standards to metabolite peaks. Identification is further confirmed by mass spectrometry. To our knowledge this is the first ion exchange method reported for the quantitation of siRNA from a biological matrix. It is also the first non-denaturing chromatographic method reported for siRNA quantitation. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. Improvements in ion reflux: An electrodialytic eluent generation and suppression device for ion chromatography.

    Science.gov (United States)

    Elkin, Kyle; Riviello, John; Small, Hamish

    2015-07-17

    This work describes a membrane based electrodialytic ion reflux device (IRD), which uses water as the pumped phase and integrates isocratic and gradient eluent generation and suppression. The current design incorporates several ion exchange membranes to create discrete chambers for suppression and eluent generation, while isolating the electrodes from the analytical stream. A small volume of recycled water can be used as the pumped phase while continuously refluxing the eluent ions. This current design permits electronically controlled eluent generation of at least 16.4μeq KOHmin(-1), while maintaining low suppressed background conductivity (<0.5μS/cm). The device was operated in gradient or isocratic mode continuously for up to 6 weeks. During this period, over 500 gradient and isocratic injections were performed, showing peak retention time precision below 1.5% RSD. Published by Elsevier B.V.

  12. Separation and characterisation of beta2-microglobulin folding conformers by ion-exchange liquid chromatography and ion-exchange liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Bertoletti, Laura; Regazzoni, Luca; Aldini, Giancarlo; Colombo, Raffaella; Abballe, Franco; Caccialanza, Gabriele; De Lorenzi, Ersilia

    2013-04-10

    In this work we present for the first time the use of ion-exchange liquid chromatography to separate the native form and a partially structured intermediate of the folding of the amyloidogenic protein beta2-microglobulin. Using a strong anion-exchange column that accounts for the differences in charge exposure of the two conformers, a LC-UV method is initially optimised in terms of mobile phase pH, composition and temperature. The preferred mobile phase conditions that afford useful information were found to be 35 mM ammonium formate, pH 7.4 at 25°C. The dynamic equilibrium of the two species is demonstrated upon increasing the concentration of acetonitrile in the protein sample. Then, the chromatographic method is transferred to MS detection and the respective charge state distributions of the separated conformers are identified. The LC-MS results demonstrate that one of the conformers is partially unfolded, compared with the native and more compact species. The correspondence with previous results obtained in free solution by capillary electrophoresis suggest that strong ion exchange LC-MS does not alter beta2-microglobulin conformation and maintains the dynamic equilibrium already observed between the native protein and its folding intermediate. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. Online ion-exchange chromatography for small-angle X-ray scattering.

    Science.gov (United States)

    Hutin, Stephanie; Brennich, Martha; Maillot, Benoit; Round, Adam

    2016-10-01

    Biological small-angle X-ray scattering (BioSAXS) is a powerful technique to determine the solution structure, particle size, shape and surface-to-volume ratio of macromolecules. However, a drawback is that the sample needs to be monodisperse. To ensure this, size-exclusion chromatography (SEC) has been implemented on many BioSAXS beamlines. Here, the integration of ion-exchange chromatography (IEC) using both continuous linear and step gradients on a beamline is described. Background subtraction for continuous gradients by shifting a reference measurement and two different approaches for step gradients, which are based on interpolating between two background measurements, are discussed. The results presented here serve as a proof of principle for online IEC and subsequent data treatment.

  14. Measurement of radionuclides using ion chromatography and flow-cell scintillation counting with pulse shape discrimination

    Energy Technology Data Exchange (ETDEWEB)

    DeVol, T.A.; Fjeld, R.A. [Clemson Univ., Clemson, SC (United States)

    1995-10-01

    The use of ion chromatography (IC) for radiochemical separations is a well established technique. IC is commonly used in routine environmental monitoring applications as well as in specialized research applications. Typical usage involves the separation of a single radionuclide from the non-radioactive constituents. During the past decade, a limited amount of research has been conducted using automated IC systems in actinide separation applications (e.g.). More recently, separation procedures for common non-gamma emitting activation and fission products were developed utilizing a high performance liquid chromatography (HPLC) system. In addition, a separation procedure for six common actinides has been developed using a HPLC system. These latter systems used on-line flow-cell detectors for quantification of the radioactive constituents of the effluent stream.

  15. Simulation model for overloaded monoclonal antibody variants separations in ion-exchange chromatography.

    Science.gov (United States)

    Guélat, Bertrand; Ströhlein, Guido; Lattuada, Marco; Delegrange, Lydia; Valax, Pascal; Morbidelli, Massimo

    2012-08-31

    A model was developed for the design of a monoclonal antibody charge variants separation process based on ion-exchange chromatography. In order to account for a broad range of operating conditions in the simulations, an explicit pH and salt concentration dependence has been included in the Langmuir adsorption isotherm. The reliability of this model was tested using experimental chromatographic retention times as well as information about the structural characteristics of the different charge variants, e.g. C-terminal lysine groups and deamidated groups. Next, overloaded isocratic elutions at various pH and salt concentrations have been performed to determine the saturation capacity of the ion-exchanger. Furthermore, the column simulation model was applied for the prediction of monoclonal antibody variants separations with both pH and salt gradient elutions. A good prediction of the elution times and peak shapes was observed, even though none of the model parameters was adjusted to fit the experimental data. The trends in the separation performance obtained through the simulations were generally sufficient to identify the most promising operating conditions. The predictive column simulation model thus developed in this work, including a set of parameters determined through specific independent experiments, was experimentally validated and offers a useful basis for a rational optimization of monoclonal antibody variants separation processes on ion-exchange chromatography. Copyright © 2012 Elsevier B.V. All rights reserved.

  16. Capillary ion-exchange chromatography with nanogram sensitivity for the analysis of monoclonal antibodies.

    Science.gov (United States)

    Rea, Jennifer C; Freistadt, Benny S; McDonald, Daniel; Farnan, Dell; Wang, Yajun Jennifer

    2015-12-11

    Ion-exchange chromatography (IEC) is widely used for profiling the charge heterogeneity of proteins, including monoclonal antibodies (mAbs). Despite good resolving power and robustness, ionic strength-based ion-exchange separations are generally product specific and can be time consuming to develop. In addition, conventional analytical scale ion-exchange separations require tens of micrograms of mAbs for each injection, amounts that are often unavailable in sample-limited applications. We report the development of a capillary IEC (c-IEC) methodology for the analysis of nanogram amounts of mAb charge variants. Several key modifications were made to a commercially available liquid chromatography system to perform c-IEC for charge variant analysis of mAbs with nanogram sensitivity. We demonstrate the method for multiple monoclonal antibodies, including antibody fragments, on different columns from different manufacturers. Relative standard deviations of <10% were achieved for relative peak areas of main peak, acidic and basic regions, which are common regions of interest for quantifying monoclonal antibody charge variants using IEC. The results herein demonstrate the excellent sensitivity of this c-IEC characterization method, which can be used for analyzing charge variants in sample-limited applications, such as early-stage candidate screening and in vivo studies. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Rapid isolation and purification of phorbol esters from Jatropha curcas by high-speed countercurrent chromatography.

    Science.gov (United States)

    Hua, Wan; Hu, Huiling; Chen, Fang; Tang, Lin; Peng, Tong; Wang, Zhanguo

    2015-03-18

    In this work, a high-speed countercurrent chromatography (HSCCC) method was established for the preparation of phorbol esters (PEs) from Jatropha curcas. n-Hexane-ethyl acetate-methanol-water (1.5:1.5:1.2:0.5, v/v) was selected as the optimum two-phase solvent system to separate and purify jatropha factor C1 (JC1) with a purity of 85.2%, as determined by HPLC, and to obtain a mixture containing four or five PEs. Subsequently, continuous semipreparative HPLC was applied to further purify JC1 (99.8% as determined by HPLC). In addition, UPLC-PDA and UPLC-MS were established and successfully used to evaluate the isolated JC1 and PE-rich crude extract. The purity of JC1 was only 87.8% by UPLC-UV. A peak (a compound highly similar to JC1) was indentified as the isomer of JC1 by comparing the characteristic UV absorption and MS spectra. Meanwhile, this strategy was also applied to analyze the PE-rich crude extract from J. curcas. It is interesting that there may be more than 15 PEs according to the same quasi-molecular ion peaks, highly similar sequence-specific fragment ions, and similar UV absorption spectrum.

  18. Rapid and sensitive liquid chromatography tandem mass spectrometry method for the quantification of ambroxol in human plasma.

    Science.gov (United States)

    Hu, Wanqun; Xu, Yu; Liu, Fei; Liu, Aixiang; Guo, Qingxiang

    2008-10-01

    A sensitive, specific and rapid high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was described and validated for the quantification of ambroxol in human plasma using enalaprilat as the internal standard (IS). Chromatographic separation was performed on a Lichrospher CN column with a mobile phase of methanol and water (containing 0.1% formic acid) (70:30, v/v). The total run time was 5.0 min for each sample. The analytes was detected by mass spectrometry with electrospray ionization source in positive selected reaction monitoring mode. The precursor-fragment ion reaction for ambroxol was m/z 378.9 --> 263.8, and for IS was m/z 349.0 --> 205.9. The linearity was established over the concentration range of 1.56-400.00 ng/mL. The inter-day and the intra-day precisions were all within 10%. A simple protein precipitation with methanol was adopted for sample preparation. The extraction recoveries of ambroxol and IS were higher than 90.80%. The validated method was successfully applied in pharmacokinetic study after oral administration of 90 mg ambroxol to 24 healthy volunteers.

  19. Characterization of phosphoantigens by high-performance anion-exchange chromatography-electrospray ionization ion trap mass spectrometry and nanoelectrospray ionization ion trap mass spectrometry.

    Science.gov (United States)

    Pont, F; Luciani, B; Belmant, C; Fournié, J J

    2001-08-01

    New phosphorylated microbial metabolites referred to as phosphoantigens activate immune responses in humans. Although these molecules have leading applications in medical research, no direct method allows their rapid and unambiguous structural identification. Here, we interfaced online HPAEC (high performance anion-exchange chromatography) with ESI-ITMS (electrospray ionization ion trap mass spectrometry) to identify such pyrophosphorylated molecules. A self-regenerating anion suppressor located upstream of electrospray ionization enabled the simultaneous detection of pyrophosphoester by conductimetry, UV and MS. By HPAEC-ITMS and HPAEC-ITMS2, a single run permitted characterization of reference phosphoantigens and of related structures. Although all compounds were resolved by HPAEC, MS enabled their detection and identification by [M-H]- and fragment ions. Isobaric phosphoantigen analogues were also separated by HPAEC and distinguished by MS2. The relevance of this device was demonstrated for phosphoantigens analysis in human urine and plasma. Furthermore, identification of natural phosphoantigens by automatically generated 2D mass spectra from nano-ESI-ITMS is presented. This last technique permits the simultaneous performance of molecular screening of natural phosphoantigen extracts and their identification.

  20. Determination of Monochloroacetic Acid in Swimming Pool Water by Ion Chromatography-Conductivity Detection

    Directory of Open Access Journals (Sweden)

    Maria Pythias B. Espino

    2013-02-01

    Full Text Available In this study, an analytical method involving ion chromatography with conductivity detection was developed and optimized for the determination of monochloroacetic acid in swimming pool water. The ion chromatographic method has a detection limit of 0.02 mg L-1 and linear range of 0.05 to 1.0 mg L-1 with correlation coeff icient of 0.9992. The method is reproducible with percent RSD of 0.052% (n=10. The recovery of monochloroacetic acid spiked in different water types (bottled, tap and swimming pool water ranged from 28 to 122%. In dilute solutions, chloride and bromide were simultaneously analyzed along with monochloroacetic acid using the optimized method. Chloride and bromide have detection limits of 0.01 to 0.05 mg L-1, respectively. The usefulness of the ion chromatographic method was demonstrated in the analysis of monochloroacetic acid in swimming pool water samples. In such highly-chlorinated samples, an Ag/H cartridge was used prior to the ion chromatographic determination so as to minimize the signal due to chloride ion. Monochloroacetic acid was detected in concentrations between 0.020 and 0.093 mg L-1 in three of the six swimming pool water samples studied. The presence of monochloroacetic acid in the swimming pool water samples suggests the possible occurrence of other disinfection by-products in these waters.

  1. Rapid crystallization of externally produced ions in a Penning trap

    CERN Document Server

    Murboeck, T; Birkl, G; Noertershaeuser, W; Thompson, R C; Vogel, M

    2016-01-01

    We have studied the cooling dynamics, formation process and geometric structure of mesoscopic crystals of externally produced magnesium ions in a Penning trap. We present a cooling model and measurements for a combination of buffer gas cooling and laser cooling which has been found to reduce the ion kinetic energy by eight orders of magnitude from several hundreds of eV to micro-eV and below within seconds. With ion numbers of the order of 1000 to 100000, such cooling leads to the formation of ion Coulomb crystals which display a characteristic shell structure in agreement with theory of non-neutral plasmas. We show the production and characterization of two-species ion crystals as a means of sympathetic cooling of ions lacking a suitable laser-cooling transition.

  2. Rapid measurement of phytosterols in fortified food using gas chromatography with flame ionization detection.

    Science.gov (United States)

    Duong, Samantha; Strobel, Norbert; Buddhadasa, Saman; Stockham, Katherine; Auldist, Martin; Wales, Bill; Orbell, John; Cran, Marlene

    2016-11-15

    A novel method for the measurement of total phytosterols in fortified food was developed and tested using gas chromatography with flame ionization detection. Unlike existing methods, this technique is capable of simultaneously extracting sterols during saponification thus significantly reducing extraction time and cost. The rapid method is suitable for sterol determination in a range of complex fortified foods including milk, cheese, fat spreads, oils and meat. The main enhancements of this new method include accuracy and precision, robustness, cost effectiveness and labour/time efficiencies. To achieve these advantages, quantification and the critical aspects of saponification were investigated and optimised. The final method demonstrated spiked recoveries in multiple matrices at 85-110% with a relative standard deviation of 1.9% and measurement uncertainty value of 10%. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Rapid analysis of starch, amylose and amylopectin by high-performance size-exclusion chromatography.

    Science.gov (United States)

    Kobayashi, S; Schwartz, S J; Lineback, D R

    1985-02-01

    Starch components, amylose and amylopectin, were analyzed by high-performance size-exclusion chromatography. These two-components were separated using a two-column system (E-Linear and E-1000) and dimethyl sulphoxide as the mobile phase. The void volume (V0 = 2.22 ml) was measured using tobacco mosaic virus. Column calibration was accomplished with dextrans of known average molecular weight (Mw range = 10,100-2,000,000). The elution volume of amylopectin (Ve = 2.5 ml) indicated that this starch component was fractionated on the column system despite its very large molecular size. Standard curves were prepared from various mixtures of purified corn and wheat amylose and amylopectin. From the linear relationships obtained, the percentages of both components in corn and wheat starches were determined. The method developed proved useful to monitor the purity of amylose and amylopectin preparations, and to estimate rapidly the amylose:amylopectin ratio of starch samples.

  4. Rapid and sensitive liquid chromatography-mass spectrometry method for determination of ropinirole in human plasma.

    Science.gov (United States)

    Bhatt, Jignesh; Jangid, Arvind; Shetty, Raghavendra; Shah, Bhavin; Kambli, Sandeep; Subbaiah, Gunta; Singh, Sadhana

    2006-03-18

    A rapid and robust liquid chromatography-mass spectrometry (LC-MS/MS) method was developed for non-ergoline dopamine D(2)-receptor agonist, ropinirole in human plasma using Es-citalopram oxalate as an internal standard. The method involves solid phase extraction from plasma, reversed-phase simple isocratic chromatographic conditions and mass spectrometric detection that enables a detection limit at picogram levels. The proposed method was validated with linear range of 20-1,200 pg/ml. The extraction recoveries for ropinirole and internal standard were 90.45 and 65.42%, respectively. The R.S.D.% of intra-day and inter-day assay was lower than 15%. For its sensitivity and reliability, the proposed method is particularly suitable for pharmacokinetic studies.

  5. Comparison of different transition metal ions for immobilized metal affinity chromatography of selenoprotein P from human plasma

    DEFF Research Database (Denmark)

    Sidenius, U; Farver, O; Jøns, O

    1999-01-01

    Cu2+, Ni2+, Zn2+, Co2+ and Cd2+ were evaluated in metal ion affinity chromatography for enrichment of selenoprotein P, and immobilized Co2+ affinity chromatography was found to be the most selective chromatographic method. The chromatography was performed by fast protein liquid chromatography...... and the fractionation was followed by analysis of the collected fractions for selenium by inductively coupled plasma mass spectrometry. By the combination of immobilized Co2+ affinity chromatography and heparin affinity chromatography a simple method was developed yielding a 14,800-fold enrichment of selenoprotein P....... The purity of the protein was determined by SDS-PAGE and by sequencing from polyvinylidene difluoride blots of SDS-PAGE gels....

  6. Characterization of polysorbate 85, a nonionic surfactant, by liquid chromatography vs. ion mobility separation coupled with tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Solak Erdem, Nilüfer; Alawani, Nadrah; Wesdemiotis, Chrys, E-mail: wesdemiotis@uakron.edu

    2014-01-15

    Graphical abstract: -- Highlights: •Liquid chromatography (LC) separates amphiphilic blends according to hydrophobicity. •Ion mobility (IM) spectrometry separates these blends based on molecular size/shape. •LC–MS provides the separation resolution needed for quantifying fatty acid content. •IM–MS enables rapid, solvent-free separation and the detection of trace components. •With either method, tandem MS allows to count the hydrophobic substituents. -- Abstract: Liquid chromatography (LC) and ion mobility (IM) separation have been coupled with mass spectrometry (MS) and tandem mass spectrometry (MS{sup 2}) to characterize a commercially important nonionic surfactant, polysorbate 85. The constituents of this amphiphilic blend contained a sorbitan or isosorbide core that was chain extended with poly(ethylene oxide) (PEO) and partially esterified at the PEO termini with oleic acid or, to a lesser extent, other fatty acids. Using interactive LC in reverse-phase mode, the oligomers of the surfactant were separated according to their hydrophobicity/hydrophilicity balance. On the other hand, IM spectrometry dispersed the surfactant oligomers by their charge and collision cross section (i.e. size/shape). With either separation method, an increased number of fatty ester groups and/or lack of the polar sorbitan (or isosorbide) core led to higher retention/drift times, enabling the separation of isobaric species or species with superimposed isotope patterns, so that their ester content could be conclusively identified by MS{sup 2}. LC–MS and IM–MS permitted the detection of several byproducts besides the major PEO-sorbitan oleate oligomers. LC–MS provides the separation resolution needed for quantitative determination of the degree of esterification. IM–MS, which minimizes analysis time and solvent use, is ideally suitable for a fast, qualitative survey of samples differing in their minor constituents or impurities.

  7. Histamine Levels in 3 Types of Iranian Cheese by Ion-Exchange Chromatography

    OpenAIRE

    Ali EHSANI; Razzagh MAHMOUDI; Mina KHODAYARII; Payman ZARE

    2012-01-01

    Three types of Iranian cheese including Feta, Lighvan and Kope were investigated on the basis of histamine content as a biogenic amine. The separation and determination of this compound were performed by ion-exchange chromatography. Results indicated significant differences in histamine contents among the three types of cheeses, with the highest mean content of 42.6 mg/100g for Kope cheese, and the lowest mean level of 4.99 mg/100g in Feta cheese. In microbiological studies, Kope cheese sampl...

  8. Determination of nitrate in lettuce by ion chromatography after microwave water extraction

    Directory of Open Access Journals (Sweden)

    Humberto Brevilato Novaes

    2009-01-01

    Full Text Available Lettuce is worldwide known as the most important vegetable. In this context, most farmers are searching new techniques for best quality products including hydropony. However, nitrate is of great concern, since it has a negative impact on human metabolism. The main objective of the present work was to evaluate the nitrate content of lettuce produced by conventional and hydroponic systems. The determination was conducted by ion chromatography and a new method of extraction was tested using microwave oven digestion. The results indicated that nitrate level produced in the conventional system was lower than in the hydroponic system.

  9. Preparative frontal size-exclusion chromatography of mineral ions on neutral hypercrosslinked polystyrene.

    Science.gov (United States)

    Davankov, Vadim; Tsyurupa, Maria

    2005-09-16

    Hypercrosslinked polystyrene, being the first and the only one accessible for water microporous hydrophobic polymeric sorbent, was found to provide efficient separation of inorganic electrolytes under conditions of a frontal size-exclusion chromatography (SEC). The process, based on the difference in size of hydrated competing ions, permits separations of many pairs of salts, acids, and bases. The productivity of separation increases with the concentration of the feed solution rising. Remarkably, concentrations of the separated components in corresponding fractions may substantially exceed those in the initial mixture, which can be explained in terms of a conception of an ideal separation process.

  10. Anion exchangers with branched functional ion exchange layers of different hydrophilicity for ion chromatography.

    Science.gov (United States)

    Shchukina, O I; Zatirakha, A V; Smolenkov, A D; Nesterenko, P N; Shpigun, O A

    2015-08-21

    Novel polystyrene-divinylbenzene (PS-DVB) based anion exchangers differing from each other in the structure of the branched functional ion exchange layer are prepared to investigate the role of linker and functional site on ion exchange selectivity. The proposed method of synthesis includes the obtaining of aminated PS-DVB particles by means of their acylation with following reductive amination with methylamine. Further modification of the obtained secondary aminogroups is provided by the alkylation with either 1,4-butanediol diglycidyl ether (1,4-BDDGE) or resorcinol diglycidyl ether (RDGE), which form the linkers of different hydrophobicity, and amination of terminal epoxide rings with trimethylamine (TMA), dimethylethanolamine (DMEA), methyldiethanolamine (MDEA) or triethanolamine (TEA). The variation of the structure and hydrophobicity of the linker and terminal quaternary ammonium sites in the functional layer allows the alteration of selectivity and separation efficiency of the obtained adsorbents. The ion exchange selectivity and separation efficiency of the anion exchangers are evaluated using the model mixtures of anions (F(-), HCOO(-), Cl(-), NO2(-), Br(-), NO3(-), HPO4(2-) and SO4(2-)) in potassium hydroxide eluents. The adsorbents show the decrease of selectivity with increasing the hydrophilicity of the terminal functional site. The anion exchangers having more flexible and hydrophilic 1,4-BDDGE linker provide smaller separation factors for most of the analytes as compared with RDGE-containing adsorbents with the same terminal ion exchange sites, but are characterized with higher column efficiencies and better peak symmetry for polarizable anions. In case of 1,4-BDDGE-modified anion exchangers of the particle size of 3.3μm functionalized with DMEA and MDEA the calculated values of column efficiencies for polarizable NO3(-) and Br(-) are up to 49,000 and 53,000N/m, respectively, which is almost twice higher than the values obtained for the RDGE

  11. Purification of dirucotide, a synthetic 17-aminoacid peptide, by ion exchange centrifugal partition chromatography.

    Science.gov (United States)

    Boudesocque, Leslie; Forni, Luciano; Martinez, Agathe; Nuzillard, Jean-Marc; Giraud, Matthieu; Renault, Jean-Hugues

    2017-09-01

    Dirucotide is a synthetic drug candidate for the treatment of multiple sclerosis. This 17-aminoacid peptide was successfully purified by ion exchange centrifugal partition chromatography. The optimized conditions involved the biphasic methyl tert-butyl ether/acetonitrile/n-butanol/water (2:1:2:5, v/v) solvent system in the descending mode, the di(2-ethylhexyl)phosphoric acid cation-exchanger with an exchanger (di(2-ethylhexyl)phosphoric acid)/dirucotide mole ratio of 100 and Ca2+ ions in aqueous solution as displacer. Critical impurities were efficiently eliminated and dirucotide was recovered in high yield and purity (69% and 98%, respectively) and with a productivity of 2.29g per liter of stationary phase per hour. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Analysis of perchlorate, thiocyanate, nitrate and iodide in human amniotic fluid using ion chromatography and electrospray tandem mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Blount, Benjamin C. [Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention, Atlanta, GA 30341 (United States)]. E-mail: bblount@cdc.gov; Valentin-Blasini, Liza [Division of Laboratory Sciences, National Center for Environmental Health, Centers for Disease Control and Prevention, Atlanta, GA 30341 (United States)

    2006-05-10

    Because of health concerns surrounding in utero exposure to perchlorate, we developed a sensitive and selective method for quantifying iodide, as well as perchlorate and other sodium-iodide symporter (NIS) inhibitors in human amniotic fluid using ion chromatography coupled with electrospray ionization tandem mass spectrometry. Iodide and NIS inhibitors were quantified using a stable isotope-labeled internal standards (Cl{sup 18}O{sub 4} {sup -}, S{sup 13}CN{sup -} and {sup 15}NO{sub 3} {sup -} with excellent assay accuracy of 100%, 98%, 99%, 95% for perchlorate, thiocyanate, nitrate and iodide, respectively, in triplicate analysis of spiked amniotic fluid sample). Excellent analytical precision (<5.2% RSD for all analytes) was found when amniotic fluid quality control pools were repetitively analyzed for iodide and NIS-inhibitors. Selective chromatography and tandem mass spectrometry reduced the need for sample cleanup, resulting in a rugged and rapid method capable of routinely analyzing 75 samples/day. Analytical response was linear across the physiologically relevant concentration range for the analytes. Analysis of a set of 48 amniotic fluid samples identified the range and median levels for perchlorate (0.057-0.71, 0.18 {mu}g/L), thiocyanate (<10-5860, 89 {mu}g/L), nitrate (650-8900, 1620 {mu}g/L) and iodide (1.7-170, 8.1 {mu}g/L). This selective, sensitive, and rapid method will help assess exposure of the developing fetus to low levels of NIS-inhibitors and their potential to inhibit thyroid function.

  13. Using contemporary liquid chromatography theory and technology to improve capillary gradient ion-exchange separations.

    Science.gov (United States)

    Wouters, Bert; Broeckhoven, Ken; Wouters, Sam; Bruggink, Cees; Agroskin, Yury; Pohl, Christopher A; Eeltink, Sebastiaan

    2014-11-28

    The gradient-performance limits of capillary ion chromatography have been assessed at maximum system pressure (34.5 MPa) using capillary columns packed with 4.1 μm macroporous anion-exchange particles coated with 65 nm positively-charged nanobeads. In analogy to the van-Deemter curve, the gradient performance was assessed applying different flow rates, while decreasing the gradient time inversely proportional to the increase in flow rate in order to maintain the same retention properties. The gradient kinetic-performance limits were determined at maximum system pressure, applying tG/t0=5, 10, and 20. In addition, the effect of retention on peak width was assessed in gradient mode for mono-, di-, and trivalent inorganic anions. The peak width of late-eluting ions can be significantly reduced by using concave gradient, resulting in better detection sensitivity. A signal enhancement factor of 8 was measured for a late-eluting ion when applying a concave instead of a linear gradient. For the analysis of a complex anion mixture, a coupled column with a total length of 1.05 m was operated at the kinetic-performance limit applying a linear 250 min gradient (tG/t0=10). The peak capacity varied between 200 and 380 depending on analyte retention, and hence on charge and size of the ion. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Determination of Bromate at Trace Level in Sudanese Bottled Drinking Water Using Ion Chromatography

    Directory of Open Access Journals (Sweden)

    Mei Musa

    2010-01-01

    Full Text Available Bromate ion was determined by ion chromatography with spectro-photometric detection after post column reaction with o-dianisidine reagent in acidic medium. IonPac AS19 anion-exchange column was used with 20 mM sodium hydroxide eluent. The eluent from the column was then allowed to react with o-dianisidine at 60 °C. The developed colour of the final product was measured spectrophotometrically at 450 nm. Linearity of the method was checked up to 200 μg/L by using 200 μL sample injection volume and the linear correlation coefficient was 0.9998. The method detection limit was 0.56 μg/L and the precision was 6.2% at 100 μg/L. The spiked recovery for bromate in water samples was 93%. Interferences from some anions eg. nitrate, chloride and nitrite were studied. The method was applied for the determination of bromate ion in ten sudanese bottled drinking water. Bromate was detected in 60% of the samples at concentrations ranged between 5-169 μg/L.

  15. The principle of pooled calibrations and outlier retainment elucidates optimum performance of ion chromatography.

    Science.gov (United States)

    Andersen, Jens E T; Mikolajczak, Maria; Wojtachnio-Zawada, Katarzyna Olga; Nicolajsen, Henrik Vigan

    2012-11-01

    A principle with quality assurance of ion chromatography (IC) is presented. Since the majority of scientists and costumers are interested in the determination of the true amount of analyte in real samples, the focus of attention should be directed towards the concept of accuracy rather than focussing on precision. By exploiting the principle of pooled calibrations and retainment of all outliers it was possible to obtain full correspondence between calibration uncertainty and repetition uncertainty, which for the first time evidences statistical control in experiments with ion chromatography. Anions of bromide were analysed and the results were subjected to quality assurance (QA). It was found that the limit of quantification (LOQ) was significantly underestimated by up to a factor of 30 with respect to the determination of concentration of unknowns. The concept of lower-limit of analysis (LLA) and upper-limit of analysis (ULA) were found to provide more acceptable limits with respect to reliable analysis with a limited number of repetitions. An excellent correspondence was found between calibration uncertainty and repetition uncertainty. These findings comply with earlier investigations of method validations where it was found that the principle of pooled calibrations provides a more realistic picture of the analytical performance with the drawback, however, that generally higher levels of uncertainties should be accepted, as compared to contemporary literature values. The implications to the science analytical chemistry in general and to method validations in particular are discussed. Copyright © 2012 Elsevier B.V. All rights reserved.

  16. Separation of Aliphatic and Aromatic Carboxylic Acids by Conventional and Ultra High Performance Ion Exclusion Chromatography.

    Science.gov (United States)

    Mansour, Fotouh R; Kirkpatrick, Christine L; Danielson, Neil D

    2013-06-01

    An ion exclusion chromatography (IELC) comparison between a conventional ion exchange column and an ultra-high performance liquid chromatography (UHPLC) dynamically surfactant modified C18 column for the separation of an aliphatic carboxylic acid and two aromatic carboxylic acids is presented. Professional software is used to optimize the conventional IELC separation conditions for acetylsalicylic acid and the hydrolysis products: salicylic acid and acetic acid. Four different variables are simultaneously optimized including H 2 SO 4 concentration, pH, flow rate, and sample injection volume. Thirty different runs are suggested by the software. The resolutions and the time of each run are calculated and feed back to the software to predict the optimum conditions. Derringer's desirability functions are used to evaluate the test conditions and those with the highest desirability value are utilized to separate acetylsalicylic acid, salicylic acid, and acetic acid. These conditions include using a 0.35 m M H 2 SO 4 (pH 3.93) eluent at a flow rate of 1 mL min -1 and an injection volume of 72 μL. To decrease the run time and improve the performance, a UHPLC C18 column is used after dynamic modification with sodium dodecyl sulfate. Using pure water as a mobile phase, a shorter analysis time and better resolution are achieved. In addition, the elution order is different from the IELC method which indicates the contribution of the reversed-phase mode to the separation mechanism.

  17. Relationship of Ambient Atmosphere and Biological Aerosol Responses from a Fielded Pyrolysis-Gas Chromatography-Ion Mobility Spectrometry Bioanalytical Detector

    National Research Council Canada - National Science Library

    Snyder, A

    2003-01-01

    .... A pyrolysis-gas chromatography-ion mobility spectrometry stand-alone bioaerosol system was interfaced to an aerosol concentrator to collect ambient background aerosols and produce bioanalytical...

  18. Two novel haemoglobin variants that affect haemoglobin A1c measurement by ion-exchange chromatography.

    Science.gov (United States)

    Bots, Michael; Stroobants, An K; Delzenne, Barend; Soeters, Maarten R; de Vries, Johan E; Weykamp, Cas W; Norg, Roelf J C; Veldthuis, Martijn; Zwieten, Rob van

    2015-08-01

    Haemoglobin (Hb) variants are well-known factors interfering with accurate HbA1c testing. This report describes two novel Hb variants leading to inappropriate quantification of HbA1c by ion-exchange chromatography. Glycated forms of novel Hb variants were recognised in the blood of two patients with diabetes mellitus screened by HbA1c ion-exchange chromatography. Dedicated high-resolution cation-exchange chromatography and subsequent DNA sequencing revealed the exact nature of the variants. Other common techniques for quantifying HbA1c were applied on both samples and haematological parameters were determined to judge possible pathology associated with the novel Hb variants. A fraction of 15% of abnormal Hb was observed in a 37-year-old female. DNA sequencing revealed a heterozygous mutation in the α1-globin gene, resulting in a leucine-to-phenylalanine amino-acid substitution (HBA1: c.301C>T, p.Leu101Phe). We named this variant Hb Weesp. The other novel variant, Hb Haelen, presented as a 40% fraction in a 63-year-old male and resulted from a heterozygous amino acid substitution in the β-globin gene (HBB: c.335T>C, p.Val112Gly). The presence of both Hb variants resulted in aberrant separation of the Hb components, leading to an inadequate quantification of HbA1c. Close examination of HbA1c chromatograms revealed two novel, clinically silent Hb variants that interfere with HbA1c quantification. Healthcare providers need to be aware of the potential of such Hb variants when interpreting HbA1c results.

  19. Protein C production: metal ion/protein interfacial interaction in immobilized metal affinity chromatography.

    Science.gov (United States)

    Lee, James J; Thiessen, Eileen; Bruley, Duane F

    2005-01-01

    Protein C (PC) is an essential blood factor in the human blood coagulation cascade. PC can help achieve blood hemostasis in many deadly disease conditions such as sepsis, cancer, HIV, etc.; reduced oxygen transport due to blood agglutination within the body can cause tissue death and organ failure as a result of low oxygen transport. Our goal is to produce large quantities of low cost zymogen PC for the treatment and prevention of blood clotting resulting from many disease states, as well as provide an effective therapy for PC deficiency. Current studies show that Immobilized Metal Affinity Chromatography (IMAC) has high specificity and can be used for difficult separations among homologous proteins at relatively low cost compared to current methods, such as Immunoaffinity Chromatography. Thus, we are investigating the optimization of IMAC for the separation and purification of PC from Cohn fraction IV-I. Molecular interactions within the chromatography column involve many parameters that include: the use and type of chromatographic gel and buffer solution, the pH, temperature, metal ion, chelator, and the sequence and structure of the protein itself. These parameters all influence the protein's interaction with the column. Experimental equilibrium isotherms show that PC has primary and secondary binding characteristics, demonstrating that the interaction is not just a simple process of one protein binding to one metal ion. Understanding the thermodynamics of interfacial interaction between proteins and surface-bound Cu2+ is essential to optimizing IMAC for PC purification, as well as for separation of other proteins in general. Hence we are undertaking theoretical and experimental studies of IDA-Cu/PC adsorption. The differences in structures of PC and other critical homologous blood factors are examined using the protein visualization program Cn3D. A better understanding of the interfacial phenomena will help determine the most effective conditions to achieve our

  20. Evaluation of the thermal effect on separation selectivity in anion-exchange processes using superheated water ion-exchange chromatography.

    Science.gov (United States)

    Shibukawa, Masami; Taguchi, Akihiko; Suzuki, Yusuke; Saitoh, Kazunori; Hiaki, Toshihiko; Yarita, Takashi

    2012-07-07

    The thermal effect on retention and separation selectivity of inorganic anions and aromatic sulfonate ions in anion-exchange chromatography is studied on a quaternized styrene-divinylbenzene copolymer anion-exchange column in the temperature range of 40-120 °C using superheated water chromatography. The selectivity coefficient for a pair of identically charged anions approaches unity as temperature increases provided the ions have the same effective size, such that the retention of an analyte ion decreases with an increase in temperature when the analyte ion has stronger affinity for the ion-exchanger than that of the eluent counterion, whereas it increases when it has weaker affinity. The change in anion-exchange selectivity with temperature observed with superheated water chromatography has been discussed on the basis of the effect of temperature on hydration of the ions. At elevated temperatures, especially in superheated water, the electrostatic interaction or association of the ions with the fixed ion in the resin phase becomes a predominant factor resulting in a different separation selectivity from that obtained at ambient temperature.

  1. Validation data for the determination of perchlorate in water using ion chromatography with suppressed conductivity detection.

    Science.gov (United States)

    Seiler, Maike A; Jensen, Detlef; Neist, Udo; Deister, Ursula K; Schmitz, Franz

    2016-01-01

    Perchlorate salts are relatively stable, soluble in water, and migrate into groundwater sources. Groundwater is an essential source for drinking water suppliers. Perchlorate bears health risks as it is identified to impair normal thyroid function by interfering with iodine uptake by the thyroid gland. The development of a sensitive analytical method for the determination of perchlorate is therefore of the highest interest or public health. Ion chromatography is a sensitive method suitable for perchlorate determinations. This manuscript describes the validation of an ion chromatographic method. Perchlorate is determined by ion chromatography (IC) with conductivity detection after suppression (CD) applying isocratic elution. In this study, the suitability of IC-CD was tested for synthetic samples, selected environmental water, drinking water, and swimming pool water in order to evaluate potential matrix effects on the perchlorate signal even after sample preparation. A sample injection volume of 750 μL was applied to the selected 2-mm-IC column. In untreated samples, the perchlorate peak can be interfered by neighbouring signals from matrix ions like chloride, nitrate, carbonate, and sulphate. Depending on the concentration of the matrix ions, the perchlorate peak can show asymmetric shape in particular when the perchlorate concentration is low. Recovery is reduced with increasing matrix ion concentrations. Dedicated matrix elimination was applied to minimize such effects. A reporting limit of 1.5 μg/L perchlorate and an expanded measurement uncertainty of 13.2 % were achieved. The extended method validation proves the applicability of IC based on the EPA 314.0 method for the determination of trace amounts of perchlorate in water samples of different origin. The results support the development of a respective international standard pursued by ISO. The approach evidenced its working robustness and ease of use in terms of eluent preparation, chromatographic

  2. Rapid comprehensive amino acid analysis by liquid chromatography/tandem mass spectrometry: comparison to cation exchange with post-column ninhydrin detection.

    Science.gov (United States)

    Dietzen, Dennis J; Weindel, Annette L; Carayannopoulos, Mary O; Landt, Michael; Normansell, Ellen T; Reimschisel, Tyler E; Smith, Carl H

    2008-11-01

    Ion-exchange chromatography with ninhydrin detection remains the gold standard for detecting inborn errors of amino acid catabolism and transport. Disadvantages of such analysis include long chromatography times and interference from other ninhydrin-positive compounds. The aim of this project was to develop a more rapid and specific technique using liquid chromatography/tandem mass spectrometry (LC/MS/MS). Optimal fragmentation patterns for 32 amino acids were determined on a triple quadrupole mass spectrometer following butylation. Chromatographic characteristics of each of the amino acids were determined using C8 reversed-phase chromatography with 20% acetonitrile/0.1% formic acid as isocratic mobile phase. Quantitation using eleven deuterated internal standards was compared to cation exchange and ninhydrin detection on a Beckman 7300 system. Following methanol extraction and butylation, determination of 32 amino acids required 20 min. The dynamic range of each amino acid was generally 1-1000 micromol/L. Imprecision ranged from 7 to 23% (CV) over 6 months and recovery ranged from 88-125%. Deming regression with the Beckman 7300 yielded slopes from 0.4-1.2, intercepts from -21 to 65 micromol/L, correlation coefficients from 0.84-0.99 and Syx from 2-125 micromol/L. Isobaric amino acids were separated by chromatography (e.g. leucine, isoleucine) or by unique fragmentation (e.g., alanine, beta-alanine). LC/MS/MS is comparable to traditional LC-ninhydrin detection. Mass spectral detection shortens analysis times and reduces potential for interference in detecting inborn metabolic errors.

  3. Modelling gradient elution of bioactive multicomponent systems in non-linear ion-exchange chromatography.

    Science.gov (United States)

    Wiesel, A; Schmidt-Traub, H; Lenz, J; Strube, J

    2003-07-18

    A theoretical framework for the ion-exchange behaviour of bioactive substances in non-linear ion-exchange chromatogaphy is described. The aim of the study was the creation of a model basis to support a process design for production-scale ion-exchange chromatography. The theory can be applied to a whole variety of biological substances, such as amino acids, polysaccharides, peptides and proteins and either isocratic or gradient elution can be carried out. The influence of the eluent concentration on the ion-exchange as well as on the characteristic charge was considered. Experimental measurements showed a strong non-linear ion-exchange equilibrium with a transition from a Langmuir-type to a sigmoidal isotherm at higher eluent concentrations. Hereby, the compound binds to the surface though it is not ionic. Therefore, the model considered the possibility of ion-exchange as well as adsorption. A simplified distribution of the counter-ions based on the Gouy-Chapman theory with a discrete distribution of the counter-ions was used. The theory was extended by a selectivity in the double layer to allow specific adsorption. Calculations of adsorption-elution cycles showed, in agreement with the experimental observations, the development of non-linear elution profiles with a desorption fronting. As a result, the column loading and the eluent concentration were varied. The effect of contaminants, in this case sodium ions, was investigated and included in the model. Finally, the model was extended to multicomponent systems to investigate the effect of side components on the retention behaviour. The development of the characteristic elution profiles and the effect of the column loading on the separation are discussed. Calculated concentration profiles along the column at discrete time steps were used to reveal the influence of side components and the underlying separation mechanism. The simulations provided a new insight into the phenomena involved in biochromatography and make

  4. Functionalized SBA-15 mesoporous silica in ion chromatography of alkali, alkaline earths, ammonium and transition metal ions.

    Science.gov (United States)

    Bruzzoniti, Maria Concetta; De Carlo, Rosa Maria; Fiorilli, Sonia; Onida, Barbara; Sarzanini, Corrado

    2009-07-17

    The retention properties of a SBA-15 mesoporous silica functionalized with -(CH(2))(3)COOH groups, synthesized by a co-condensation route, were investigated for the ion chromatography of different cationic species. A systematic study on the effect of different eluent compositions containing non-complexing (methanesulfonic acid) or complexing (oxalic or pyridine-2,6-dicarboxylic acids) eluents, in the presence of organic modifiers (CH(3)CN, CH(3)OH, CH(3)NH(2)) on the retention of cations (Li(+), Na(+), K(+), Ca(2+), Mg(2+), Sr(2+), Ba(2+), NH(4)(+), Cu(2+), Ni(2+), Zn(2+), Cd(2+), Co(2+), Pb(2+), Fe(3+)) chosen as model analytes and for their environmental importance, allowed us to elucidate the mechanisms (cation-exchange or complexation) involved in the retention on the SBA-15 phase. For the first time separations of cations on SBA-15 based stationary phases are investigated, providing the basis for further development of mesoporous silica chemistry for in-flow ion-exchange applications.

  5. Rapid analysis of organic microcontaminants in environmental water samples by trace enrichment and liquid chromatography on a single short column.

    NARCIS (Netherlands)

    Hogenboom, A.C.; Malmqvist, U.K.; Nolkrantz, K.; Vreuls, J.J.; Brinkman, U.A.T.

    1997-01-01

    On-column trace enrichment and liquid chromatography using a single short (20 mm length) high-pressure packed column was optimized for the rapid simultaneous identification and quantification of a wide range of organic microcontaminants in environmental water samples. The quality of different C,,

  6. Optimization of artificial neural networks used for retention modelling in ion chromatography.

    Science.gov (United States)

    Srecnik, Goran; Debeljak, Zeljko; Cerjan-Stefanović, Stefica; Novic, Milko; Bolancab, Tomislav

    2002-10-11

    The aim of this work is the development of an artificial neural network model, which can be generalized and used in a variety of applications for retention modelling in ion chromatography. Influences of eluent flow-rate and concentration of eluent anion (OH-) on separation of seven inorganic anions (fluoride, chloride, nitrite, sulfate, bromide, nitrate, and phosphate) were investigated. Parallel prediction of retention times of seven inorganic anions by using one artificial neural network was applied. MATLAB Neural Networks ToolBox was not adequate for application to retention modelling in this particular case. Therefore the authors adopted it for retention modelling by programming in MATLAB metalanguage. The following routines were written; the division of experimental data set on training and test set; selection of data for training and test set; Dixon's outlier test; retraining procedure routine; calculations of relative error. A three-layer feed forward neural network trained with a Levenberg-Marquardt batch error back propagation algorithm has been used to model ion chromatographic retention mechanisms. The advantage of applied batch training methodology is the significant increase in speed of calculation of algorithms in comparison with delta rule training methodology. The technique of experimental data selection for training set was used allowing improvement of artificial neural network prediction power. Experimental design space was divided into 8-32 subspaces depending on number of experimental data points used for training set. The number of hidden layer nodes, the number of iteration steps and the number of experimental data points used for training set were optimized. This study presents the very fast (300 iteration steps) and very accurate (relative error of 0.88%) retention model, obtained by using a small amount of experimental data (16 experimental data points in training set). This indicates that the method of choice for retention modelling in ion

  7. Determination of bromate in sea water using multi-dimensional matrix-elimination ion chromatography.

    Science.gov (United States)

    Zakaria, Philip; Bloomfield, Carrie; Shellie, Robert A; Haddad, Paul R; Dicinoski, Greg W

    2011-12-16

    A multi-dimensional matrix-elimination ion chromatography approach has been applied to the determination of bromate in seawater samples. Two-dimensional and three-dimensional configurations were evaluated for their efficacy to eliminate the interference caused by the high concentration of ubiquitous ions present in seawater, such as chloride and sulfate. A two-dimensional approach utilising a high capacity second dimension separation comprising two Dionex AS24 columns connected in series was applied successfully and permitted the determination of bromate in undiluted seawater samples injected directly onto the ion chromatography system. Using this approach the limit of detection (LOD) for bromate based on a signal to noise ratio of 3 was 1050 μg/L using a 500 μL injection loop. Good linearity was obtained for bromate with correlation coefficients for the calibration curves of 0.9981 and 0.9996 based on peak height and area, respectively. A three-dimensional method utilising two 10-port switching valves to allow sharing of the second suppressor and detector between the second and third dimension separations showed better resolution and detection for bromate and reduced the LOD to 60 μg/L for spiked seawater samples. Good linearity was maintained with correlation coefficients of 0.9991 for both peak height and area. Ozonated seawater samples were also analysed and exhibited a non-linear increase in bromate level on increasing ozonation time. A bromate concentration in excess of 1770 μg/L was observed following ozonation of the seawater sample for 120 min. Recoveries for the three-dimensional system were 92% and 89% based on peak height and area, respectively, taken over 5 ozonated samples with 3 replicates per sample. Copyright © 2011 Elsevier B.V. All rights reserved.

  8. Utilization of Ion-Exclusion Chromatography for Water Quality Monitoring in a Suburban River in Jakarta, Indonesia

    Directory of Open Access Journals (Sweden)

    Daisuke Kozaki

    2014-07-01

    Full Text Available We evaluated the use of ion-exclusion chromatographic systems for analyzing the behavior of inorganic ions (e.g., bicarbonate, sulfate, chloride, nitrate, phosphate, dissolved silicate, sodium, ammonium, potassium, magnesium, and calcium ions in a suburban river located in Jakarta, Indonesia. Carbonate, phosphate, and silicate ion concentrations were determined using ion-exclusion chromatography (IEC on a weakly acidic cation-exchange resin column (WCX in the H+-form with water eluent. Other ions were identified by ion-exclusion/cation-exchange chromatography (IEC/CEC on a WCX column with tartaric acid eluent. The use of IEC systems for water quality monitoring was advantageous for the following reasons: (1 the concentrations of analyte ions, except NO3− and silicate ions, increased from upstream to downstream; and (2 the speciation of inorganic nitrogen ions could be analyzed by single injection into the IEC/CEC. The IEC approach provided beneficial information for the construction of sewage treatment facilities in our study area. Results showed that (1 the analyte concentrations for samples obtained in the downstream area were higher than those in the upstream area owing to contamination by domestic sewage; (2 the concentrations of NO3− and NH4+ correlated with the concentration of dissolved oxygen; and (3 bicarbonate concentrations increased downstream, likely due to respiration of bacteria and dissolution of concrete under low-oxygen conditions.

  9. Anion exchangers with negatively charged functionalities in hyperbranched ion-exchange layers for ion chromatography.

    Science.gov (United States)

    Uzhel, Anna S; Zatirakha, Alexandra V; Smirnov, Konstantin N; Smolenkov, Alexandr D; Shpigun, Oleg A

    2017-01-27

    Novel pellicular poly(styrene-divinylbenzene)-based (PS-DVB) anion exchangers with covalently-bonded hyperbranched functional ion-exchange layers containing negatively charged functionalities are obtained and examined. The hyperbranched coating is created on the surface of aminated PS-DVB substrate by repeating the modification cycles including alkylation with 1,4-butanediol diglycidyl ether (1,4-BDDGE), and amination of the terminal epoxide rings with methylamine (MA) or glycine (Gly). The influence of the position and the number of the layers with glycine, as well as of the total number of the layers of amine in the coating on the chromatographic properties of the obtained stationary phases is investigated. Chromatographic performance of the obtained stationary phases is evaluated using the model mixtures of inorganic and organic anions with hydroxide eluent. It is shown that the best selectivity toward weakly retained organic acids and oxyhalides is possessed by the anion exchanger obtained after 5 modification cycles, with glycine being used in the first one. Such anion exchanger packed in 25-cm long column is capable of separating 22 anions in 58min including 7 standard anions, mono-, di- and trivalent organic acids, oxyhalides, and some other double- and triple-charged anions. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. On line pre-concentration for simultaneous determination of low molecular weight organic acids and inorganic anions in Amazonian river water samples employing ion chromatography with conductivity detection

    National Research Council Canada - National Science Library

    Cristiane Azevedo Tumang; Alex Vladimir Krusche; Reynaldo Luis Victoria; Jeffrey Edward Richey

    2009-01-01

    An ion chromatography procedure, employing an IonPac AC15 concentrator column was used to investigate on line preconcentration for the simultaneous determination of inorganic anions and organic acids in river water...

  11. Determination of sulfur anions in spent oil shale leachates by ion chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Niss, N.D.

    1989-07-01

    The leaching and transport of chemical constituents from spent oil shale disposal areas is an area of environmental concern at the present time. Sulfur-containing compounds are prevalent in spent oil shales and have the potential to leach into aqueous systems surrounding disposal sites. Computer modeling has been used in recent years to predict the transport of species in an aqueous environment. The quality of model predictions, however, depends on the validation steps taken in comparing model predictions with laboratory data on ion speciation. Further, the quality of the validation step depends on the reliability of laboratory methods in generating ion speciation data. The purpose of this study was to develop methods to separate and quantify sulfur-containing anions in spent oil shale leachates by suppressed ion chromatography. The anions studied were S{sup 2{minus}} (sulfide), SO{sup 2{minus}}{sub 3} (sulfite), SO{sup 2{minus}}{sub 4} (sulfate), SCN{sup {minus}} (thiocyanate), S{sub 2}O{sup 2{minus}}{sub 3} (thiosulfate), and S{sub 4}O{sup 2{minus}}{sub 6} (tetrathionate). After the separations were developed, a series of method-challenging experiments were performed to test the reliability of the methods and assure the development of an analytically sound product. 24 refs., 7 figs., 5 tabs.

  12. [Simultaneous determination of bromate and perchlorate in vegetable by ion chromatography tandem mass spectrometry].

    Science.gov (United States)

    Yang, Jiajia; Yang, Yi; Zhang, Jing; Shao, Bing; Wu, Yongning

    2012-03-01

    To develop a method for simultaneous determination of bromate and perchiorate in vegetable using ion chromatography tandem mass spectrometry. Target ions in vegetable matrix were extracted by water and purified using a GCB cartridge. With the hydrophilic Ion Pac AS19 column and linear gradient potassium hydroxide used as eluent, bromate and perchlorate were analyzed by a triple quadrupole mass spectrometer under negative electronspray ionization mode and multiple reaction monitoring (MRM). Internal standard calibration was used for quantification. Good linearity was achieved for bromate and perchlorate over the range of 0.1- 50 microg/L and 0.05-50 microg/L, respectively, with correlation coefficients R2 > 0.998. The quantification limits of the method were 2.5 microg/kg and 0.7 microg/kg for bromate and perchlorate, respectively. Mean recoveries of two target analytes (spiked at three concentration levels in 5 kinds of vegetables) ranged from 80.3% to 124%, with within-day precisions no more than 21.4% and intraday precisions no more than 12.2%. This method could be applied in the simultaneous detection of bromate and perchlorate in vegetable.

  13. A rapid analysis of plasma/serum ethylene and propylene glycol by headspace gas chromatography.

    Science.gov (United States)

    Ehlers, Alexandra; Morris, Cory; Krasowski, Matthew D

    2013-12-01

    A rapid headspace-gas chromatography (HS-GC) method was developed for the analysis of ethylene glycol and propylene glycol in plasma and serum specimens using 1,3-propanediol as the internal standard. The method employed a single-step derivitization using phenylboronic acid, was linear to 200 mg/dL and had a lower limit of quantitation of 1 mg/dL suitable for clinical analyses. The analytical method described allows for laboratories with HS-GC instrumentation to analyze ethanol, methanol, isopropanol, ethylene glycol, and propylene glycol on a single instrument with rapid switch-over from alcohols to glycols analysis. In addition to the novel HS-GC method, a retrospective analysis of patient specimens containing ethylene glycol and propylene glycol was also described. A total of 36 patients ingested ethylene glycol, including 3 patients who presented with two separate admissions for ethylene glycol toxicity. Laboratory studies on presentation to hospital for these patients showed both osmolal and anion gap in 13 patients, osmolal but not anion gap in 13 patients, anion but not osmolal gap in 8 patients, and 1 patient with neither an osmolal nor anion gap. Acidosis on arterial blood gas was present in 13 cases. Only one fatality was seen; this was a patient with initial serum ethylene glycol concentration of 1282 mg/dL who died on third day of hospitalization. Propylene glycol was common in patients being managed for toxic ingestions, and was often attributed to iatrogenic administration of propylene glycol-containing medications such as activated charcoal and intravenous lorazepam. In six patients, propylene glycol contributed to an abnormally high osmolal gap. The common presence of propylene glycol in hospitalized patients emphasizes the importance of being able to identify both ethylene glycol and propylene glycol by chromatographic methods.

  14. Rapid detection of economic adulterants in fresh milk by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Abernethy, Grant; Higgs, Kerianne

    2013-05-03

    A method to aid in the detection of the economically driven adulteration of fresh milk with a range of small, nitrogen containing compounds, including melamine, ammeline, ammelide, cyanuric acid, allantoin, thiourea, urea, biuret, triuret, semicarbazide, aminotriazine, 3- and 4-aminotriazole, cyanamide, dicyandiamide, guanidine, choline, hydroxyproline, nitrate, and a range of amino acids, has been developed. (15)N2-Urea is used as an internal standard. The adulteration of milk with exogenous urea has previously been difficult to detect because of the variation in the naturally occurring levels of urea in milk. However, by monitoring the contaminants biuret and triuret, which comprise up to 1% of synthetic urea, the adulteration of milk with urea-based fertilizer can be detected. We estimate that to be economically viable, adulteration of the order of 90-4000ppm of the above adulterants would need to be added to fresh milk. For most of the compounds, an arbitrary detection threshold of 2ppm is therefore more than sufficient. For biuret, a lower detection threshold, better than 0.5ppm, is desirable and the sensitivity for biuret and triuret can be improved by the post-column addition of lithium to create lithium adducts under electrospray ionisation. Sample handling involves a two-step solvent precipitation method that is deployed in a 96-well plate format, and the hydrophilic interaction liquid chromatography uses a rapid gradient (1.2min). Three separate injections, to detect the positively charged compounds, the negatively charged compounds and amino acids and finally the lithium adducts, are used. This rapid and qualitative survey method may be deployed as a second tier screening method to quickly reduce sample numbers indicated as irregular by an FTIR based screening system, and to direct analysis to appropriate quantification methods. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. Indirect ultraviolet detection of alkaline earth metal ions using an imidazolium ionic liquid as an ultraviolet absorption reagent in ion chromatography.

    Science.gov (United States)

    Liu, Yong-Qiang; Yu, Hong

    2017-04-01

    A convenient and versatile method was developed for the separation and detection of alkaline earth metal ions by ion chromatography with indirect UV detection. The chromatographic separation of Mg2+ , Ca2+ , and Sr2+ was performed on a carboxylic acid base cation exchange column using imidazolium ionic liquid/acid as the mobile phase, in which the imidazolium ionic liquid acted as an UV-absorption reagent. The effects of imidazolium ionic liquids, detection wavelength, acids in the mobile phase, and column temperature on the retention of Mg2+ , Ca2+ , and Sr2+ were investigated. The main factors influencing the separation and detection were the background UV absorption reagent and the concentration of hydrogen ion in ion chromatography with indirect UV detection. The successful separation and detection of Mg2+ , Ca2+ , and Sr2+ within 14 min were achieved using the selected chromatographic conditions, and the detection limits (S/N = 3) were 0.06, 0.12, and 0.23 mg/L, respectively. A new separation and detection method of alkaline earth metal ions by ion chromatography with indirect UV detection was developed, and the application range of ionic liquids was expanded. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Rapid determination of water- and fat-soluble vitamins with microemulsion electrokinetic chromatography.

    Science.gov (United States)

    Yin, Changna; Cao, Yuhua; Ding, Shaodong; Wang, Yun

    2008-06-06

    A rapid, reliable and reproducible method based on microemulsion electrokinetic chromatography (MEEKC) for simultaneous determination of 13 kinds of water- and fat-soluble vitamins has been developed in this work. A novel microemulsion system consisting of 1.2% (w/w) sodium lauryl sulphate (SDS), 21% (v/v) 1-butanol, 18% (v/v) acetonitrile, 0.8% (w/w) n-hexane, 20mM borax buffer (pH 8.7) was applied to improve selectivity and efficiency, as well as shorten analysis time. The composition of microemulsion used as the MEEKC running buffer was investigated thoroughly to obtain stable separation medium, as well as the optimum determination conditions. Acetonitrile as the organic solvent modifier, pH of the running buffer and 1-butanol as the co-surfactant played the most important roles for the separation of the fat-soluble vitamins, water-soluble vitamins and stabilization of system, respectively. The 13 water- and fat-soluble vitamins were baseline separated within 30 min. The system was applied to determine water- and fat-soluble vitamins in commercial multivitamin pharmaceutical formulation, good accuracy and precision were obtained with recoveries between 97% and 105%, relative standard derivations (RSDs) less than 1.8% except vitamin C, and acceptable quantitative results corresponding to label claim.

  17. On-Line Ion Exchange Liquid Chromatography as a Process Analytical Technology for Monoclonal Antibody Characterization in Continuous Bioprocessing.

    Science.gov (United States)

    Patel, Bhumit A; Pinto, Nuno D S; Gospodarek, Adrian; Kilgore, Bruce; Goswami, Kudrat; Napoli, William N; Desai, Jayesh; Heo, Jun H; Panzera, Dominick; Pollard, David; Richardson, Daisy; Brower, Mark; Richardson, Douglas D

    2017-11-07

    Combining process analytical technology (PAT) with continuous production provides a powerful tool to observe and control monoclonal antibody (mAb) fermentation and purification processes. This work demonstrates on-line liquid chromatography (on-line LC) as a PAT tool for monitoring a continuous biologics process and forced degradation studies. Specifically, this work focused on ion exchange chromatography (IEX), which is a critical separation technique to detect charge variants. Product-related impurities, including charge variants, that impact function are classified as critical quality attributes (CQAs). First, we confirmed no significant differences were observed in the charge heterogeneity profile of a mAb through both at-line and on-line sampling and that the on-line method has the ability to rapidly detect changes in protein quality over time. The robustness and versatility of the PAT methods were tested by sampling from two purification locations in a continuous mAb process. The PAT IEX methods used with on-line LC were a weak cation exchange (WCX) separation and a newly developed shorter strong cation exchange (SCX) assay. Both methods provided similar results with the distribution of percent acidic, main, and basic species remaining unchanged over a 2 week period. Second, a forced degradation study showed an increase in acidic species and a decrease in basic species when sampled on-line over 7 days. These applications further strengthen the use of on-line LC to monitor CQAs of a mAb continuously with various PAT IEX analytical methods. Implementation of on-line IEX will enable faster decision making during process development and could potentially be applied to control in biomanufacturing.

  18. IDENTIFICATION OF MICROCYSTIN TOXINS FROM A STRAIN OF MICROCYSTIS AERUGINOSA BY LIQUID CHROMATOGRAPHY INTRODUCTION INTO A HYBRID LINEAR ION TRAP-FOURIER TRANSFORM ION CYCLOTRON RESONANCE MASS SPECTROMETER

    Science.gov (United States)

    The cyclic heptapeptide microcystin toxins produced by a strain of Microcystis aeruginosa that has not been investigated previously were separated by liquid chromatography and identified by high-accuracy m/z measurements of their [M + H]+ ions and the fragment i...

  19. Selenium speciation in pretreated human urine by ion-exchange chromatography and ICP-MS detection

    DEFF Research Database (Denmark)

    Gammelgaard, Bente; Jons, O.; Bendahl, L.

    2001-01-01

    Urine samples were extracted by benzo-15-crown-5-ether to remove sodium and potassium. More than 90% of the sodium and potassium content of the urine was removed with this extraction. In a cation-exchange system based on oxalic acid at pH 3, chromatography of an untreated urine pool resulted...... in a large peak in the front together with three small peaks. In the crown ether treated pool at least five signals were obtained. When the eluent was ammonium formate at pH 3, two small signals together with a large signal in the front were obtained in untreated urine, while three more distinct peaks...... and a peak in front were obtained in the crown ether extracted urine. In both systems, two of the peaks co-eluted with selenomethionine (SeMet) and the trimethylselenonium ion (TMSe). None of the signals co-eluted with either selenocystine or selenoethionine. Urine samples from different individuals showed...

  20. Analysis of sulfonated compounds by ion-exchange high-performance liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Socher, G; Nussbaum, R; Rissler, K; Lankmayr, E

    2001-03-30

    Ion-exchange high-performance liquid chromatography (HPIEC)-mass spectrometry (MS) was used for the analysis of different sulfonated compounds. HPIEC was performed on an aminopropyl column applying a gradient with increasing concentration of a buffer consisting of ammonium acetate-acetic acid and acetonitrile as the organic modifier. HPIEC is well suited to highly efficient separation of sulfonated compounds and furthermore, due to the volatility of ammonium acetate, the method is also appropriate for LC-MS coupling by the means of either atmospheric pressure chemical ionization or electrospray ionization. The applicability range of HPIEC-MS is demonstrated on the basis of a complex mixture of model substances consisting of sulfonated aromatics and textile dyes largely differing from each other in their structural properties.

  1. Dimethylamine and ammonia measurements with ion chromatography during the CLOUD4 campaign

    CERN Document Server

    Praplan, A P; Dommen, J; Baltensperger, U

    2012-01-01

    The CLOUD project investigates the influence of galactic cosmic rays on the nucleation of new particles in an environmental chamber at CERN. Dimethylamine (DMA) was injected intentionally into the CLOUD chamber to reach atmospherically relevant levels away from sources (up to 100 pptv) in order to study its effect on nucleation with sulphuric acid and water at 278 K. Quantification of DMA and also background ammonia (NH 3 ) was performed with ion chromatography (IC). The IC method used together with the sampling line developed for CLOUD in order to measure NH 3 and DMA at low pptv levels is described; the overall sampling efficiency of the method is discussed; and, finally, mixing ratios of NH 3 and DMA measured during CLOUD4 are reported.

  2. Coxsackievirus B3 VLPs purified by ion exchange chromatography elicit strong immune responses in mice.

    Science.gov (United States)

    Koho, Tiia; Koivunen, Minni R L; Oikarinen, Sami; Kummola, Laura; Mäkinen, Selina; Mähönen, Anssi J; Sioofy-Khojine, Amirbabak; Marjomäki, Varpu; Kazmertsuk, Artur; Junttila, Ilkka; Kulomaa, Markku S; Hyöty, Heikki; Hytönen, Vesa P; Laitinen, Olli H

    2014-04-01

    Coxsackievirus B3 (CVB3) is an important cause of acute and chronic viral myocarditis, and dilated cardiomyopathy (DCM). Although vaccination against CVB3 could significantly reduce the incidence of serious or fatal viral myocarditis and various other diseases associated with CVB3 infection, there is currently no vaccine or therapeutic reagent in clinical use. In this study, we contributed towards the development of a CVB3 vaccine by establishing an efficient and scalable ion exchange chromatography-based purification method for CVB3 virus and baculovirus-insect cell-expressed CVB3 virus-like particles (VLPs). This purification system is especially relevant for vaccine development and production on an industrial scale. The produced VLPs were characterized using a number of biophysical methods and exhibited excellent quality and high purity. Immunization of mice with VLPs elicited a strong immune response, demonstrating the excellent vaccine potential of these VLPs. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Effect of modulator sorption on gradient shape in ion-exchange chromatography

    Science.gov (United States)

    Velayudhan, A.; Ladisch, M. R.; Mitchell, C. A. (Principal Investigator)

    1995-01-01

    Mobile phase additives, or modulators, are used in gradient elution chromatography to facilitate separation and reduce separation time. The modulators are usually assumed to be linearly adsorbed or unadsorbed. Here, the consequences of nonlinear modulator adsorption are examined for ion-exchange gradient elution through a series of simulations. Even when the buffer salt is identical to the modulator salt, gradient deformation is observed; the extent of deformation increases as the volume of the feed is increased. When the modulator salt is different from the buffer salt, unusual effects are observed, and the chromatograms are quite different from those predicted by classical gradient elution theory. In particular, local increases in the buffer concentration are found between feed bands, and serve to improve the separation. These effects become more pronounced as the feed volume increases, and could therefore prove valuable in preparative applications.

  4. The principle of pooled calibrations and outlier retainment elucidates optimum performance of ion chromatography

    DEFF Research Database (Denmark)

    Andersen, Jens; Mikolajczak, Maria; Wojtachnio-Zawada, Katarzyna Olga

    2012-01-01

    A principle with quality assurance of ion chromatography (IC) is presented. Since the majority of scientists and costumers are interested in the determination of the true amount of analyte in real samples, the focus of attention should be directed towards the concept of accuracy rather than...... (LLA) and upper-limit of analysis (ULA) were found to provide more acceptable limits with respect to reliable analysis with a limited number of repetitions. An excellent correspondence was found between calibration uncertainty and repetition uncertainty. These findings comply with earlier...... investigations of method validations where it was found that the principle of pooled calibrations provides a more realistic picture of the analytical performance with the drawback, however, that generally higher levels of uncertainties should be accepted, as compared to contemporary literature values...

  5. Modeling of ion exchange expanded-bed chromatography for the purification of C-phycocyanin.

    Science.gov (United States)

    Moraes, Caroline Costa; Mazutti, Marcio A; Maugeri, Francisco; Kalil, Susana Juliano

    2013-03-15

    This work is focused on the experimental evaluation and mathematical modeling of ion exchange expanded-bed chromatography for the purification of C-phycocyanin from crude fermentative broth containing Spirulina platensis cells. Experiments were carried out in different expansion degree to evaluate the process performance. The experimental breakthrough curves were used to estimate the mass transfer and kinetics parameters of the proposed model, using the Particle Swarm Optimization algorithm (PSO). The proposed model satisfactorily fitted the experimental data. The results from the model application pointed out that the increase in the initial bed height does not influence the process efficiency, however enables the operation of expanded-bed column at high volumetric flow rates, improving the productivity. It was also shown that the use of mathematical modeling was a good and promising tool for the optimization of chromatographic processes. Copyright © 2013 Elsevier B.V. All rights reserved.

  6. Uncovering biologically significant lipid isomers with liquid chromatography, ion mobility spectrometry and mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Kyle, Jennifer E.; Zhang, Xing; Weitz, Karl K.; Monroe, Matthew E.; Ibrahim, Yehia M.; Moore, Ronald J.; Cha, Jeeyeon; Sun, Xiaofei; Lovelace, Erica S.; Wagoner, Jessica; Polyak, Steve; Metz, Thomas O.; Dey, Sudhansu K.; Smith, Richard D.; Burnum-Johnson, Kristin E.; Baker, Erin Shammel

    2016-01-01

    Understanding how biological molecules are generated, metabolized and eliminated in living systems is important for interpreting processes such as immune response and disease pathology. While genomic and proteomic studies have provided vast amounts of information over the last several decades, interest in lipidomics has also grown due to improved analytical technologies revealing altered lipid metabolism in type 2 diabetes, cancer, and lipid storage disease. Liquid chromatography and mass spectrometry (LC-MS) measurements are currently the dominant approach for characterizing the lipidome by providing detailed information on the spatial and temporal composition of lipids. However, interpreting lipids’ biological roles is challenging due to the existence of numerous structural and stereoisomers (i.e. distinct acyl chain and double-bond positions), which are unresolvable using present LC-MS approaches. Here we show that combining structurally-based ion mobility spectrometry (IMS) with LC-MS measurements distinguishes lipid isomers and allows insight into biological and disease processes.

  7. Liquid chromatography/coordination ion spray-mass spectrometry for the analysis of rubber vulcanization products.

    Science.gov (United States)

    Hayen, Heiko; Alvarez-Grima, M Montserrat; Debnath, Subhas C; Noordermeer, Jacques W M; Karst, Uwe

    2004-02-15

    Liquid chromatography/coordination ion spray-mass spectrometry has been used for the identification of reaction products in a model rubber vulcanization process. After LC separation using reversed-phase conditions, AgBF(4) in acetonitrile was added, and strong signals were observed for silica-rubber coupling agents and products of the reaction between these and alkenes. The method performs best for substances containing sulfur chains with chain lengths between two and eight sulfur atoms, but sulfur-free compounds containing triethoxysilyl groups were detected as well. For the latter, the postcolumn addition of NaBF(4) proved to be a suitable alternative. Besides the coupling agents, various reaction products, including sulfur-chain bridged alkenes were identified.

  8. Modelling of cations retention in ion chromatography with methanesulfonic acid as eluent

    Directory of Open Access Journals (Sweden)

    Todorović Žaklina N.

    2017-01-01

    Full Text Available The two retention models, the linear solvent strength model (LSS and the quadratic relationship, in addition to artificial neural network (ANN approach, were compared in their ability to predict the retention behaviour of common cations (Li, Na, NH4, K, Mg, and Ca in isocratic ion chromatography using the methanesulfonic acid (MSA eluent. Over wide variations in the MSA concentration, the quadratic model shows a quite good prediction power. LSS can be used only for monovalent cations and in the proximity of the experimental design point. ANN fails to predict the retention for the data not included in the training set. To find the optimal conditions in the experimental design, the normalized resolution product as a chromatographic objective function was employed. The optimum MSA concentration in the eluent on a Dionex CS12 column was found to be 18 mM, with the total analysis time of less than 10 min. [Projekat Ministarstva nauke Republike Srbije, br. III43009

  9. Determination of chloroacetic acids in drinking water using suppressed ion chromatography with solid-phase extraction.

    Science.gov (United States)

    Yoshikawa, Kenji; Soda, Yuko; Sakuragawa, Akio

    2009-12-01

    Suppressed ion chromatography with a conductivity detector was developed for the determination of trace amounts of underivatized chloroacetic acids (CAAs). When sodium carbonate and methanol were used as a mobile phase, the simultaneous determination of each CAA took approximately 25 min. The linearity, reproducibility and detection limits were determined for the proposed method. For the solid-phase extraction step, the effects of the pH of the sample solution, sample volume and the eluting agent were tested. Under the optimized extracting conditions, the average recoveries for CAAs spiked in tap water were 83-107%, with an optimal preconcentration factor of 20. The reproducibility of recovery rate for CAAs was 1.2-3.8%, based upon 6 repetitions of the recovery experiments.

  10. Uncovering Biologically Significant Lipid Isomers with Liquid Chromatography, Ion Mobility Spectrometry and Mass Spectrometry

    Science.gov (United States)

    Kyle, Jennifer E.; Zhang, Xing; Weitz, Karl K.; Monroe, Matthew E.; Ibrahim, Yehia M.; Moore, Ronald J.; Cha, Jeeyeon; Sun, Xiaofei; Lovelace, Erica S.; Wagoner, Jessica; Polyak, Stephen J.; Metz, Thomas O.; Dey, Sudhansu K.; Smith, Richard D.; Burnum-Johnson, Kristin E.; Baker, Erin S.

    2016-01-01

    Understanding how biological molecules are generated, metabolized and eliminated in living systems is important for interpreting processes such as immune response and disease pathology. While genomic and proteomic studies have provided vast amounts of information over the last several decades, interest in lipidomics has also grown due to improved analytical technologies revealing altered lipid metabolism in type 2 diabetes, cancer, and lipid storage disease. Mass spectrometry (MS) measurements are currently the dominant approach for characterizing the lipidome by providing detailed information on the spatial and temporal composition of lipids. However, interpreting lipids’ biological roles is challenging due to the existence of numerous structural and stereoisomers (i.e. distinct acyl chain and double-bond positions), which are often unresolvable using present approaches. Here we show that combining liquid chromatography (LC) and structurally-based ion mobility spectrometry (IMS) measurement with MS analyses distinguishes lipid isomers and allows insight into biological and disease processes. PMID:26734689

  11. Size Exclusion Chromatography-Ion Mobility-Mass Spectrometry Coupling: a Step Toward Structural Biology

    Science.gov (United States)

    Van der Rest, Guillaume; Halgand, Frédéric

    2017-09-01

    Noncovalent interactions are essential for the structural organization of biomacromolecules in cells. For this reason, the study of the biophysical, dynamic, and architectural interactions among biomacromolecules is essential. Since mass spectrometry requires compatible solutions while preserving the noncovalent bonding network, we envisioned that size exclusion chromatography coupled with ion mobility and mass spectrometry would be a valuable technique to desalt the initial sample and provide solution and gas-phase structural information in a single stage experiment. Such coupling allowed obtaining information on solution protein complex composition with SEC separation and on authenticity and purity with IMS-MS. Our study demonstrated that such coupling is compatible, useful, as well as suitable for a routine analysis, in pharmaceutical industry, for example. Mobility data were reliable and injected standards allowed calibrating the collision cross-section scale. [Figure not available: see fulltext.

  12. Dimethylamine and ammonia measurements with ion chromatography during the CLOUD4 campaign

    Directory of Open Access Journals (Sweden)

    A. P. Praplan

    2012-09-01

    Full Text Available The CLOUD project investigates the influence of galactic cosmic rays on the nucleation of new particles in an environmental chamber at CERN. Dimethylamine (DMA was injected intentionally into the CLOUD chamber to reach atmospherically relevant levels away from sources (up to 100 pptv in order to study its effect on nucleation with sulphuric acid and water at 278 K. Quantification of DMA and also background ammonia (NH3 was performed with ion chromatography (IC. The IC method used together with the sampling line developed for CLOUD in order to measure NH3 and DMA at low pptv levels is described; the overall sampling efficiency of the method is discussed; and, finally, mixing ratios of NH3 and DMA measured during CLOUD4 are reported.

  13. Unfolding of a model protein on ion exchange and mixed mode chromatography surfaces.

    Science.gov (United States)

    Gospodarek, Adrian M; Hiser, Diana E; O'Connell, John P; Fernandez, Erik J

    2014-08-15

    Recent studies with proteins indicate that conformational changes and aggregation can occur during ion exchange chromatography (IEC). Such behavior is not usually expected, but could lead to decreased yield and product degradation from both IEC and multi mode chromatography (MMC) that has ligands of both hydrophobic and charged functionalities. In this study, we used hydrogen exchange mass spectrometry to investigate unfolding of the model protein BSA on IEC and MMC surfaces under different solution conditions at 25°C. Increased solvent exposure, indicating greater unfolding relative to that in solution, was found for protein adsorbed on cationic IEC and MMC surfaces in the pH range of 3.0 to 4.5, where BSA has decreased stability in solution. There was no effect of anionic surfaces at pH values in the range from 6.0 to 9.0. Differences of solvent exposure of whole molecules when adsorbed and in solution suggest that adsorbed BSA unfolds at lower pH values and may show aggregation, depending upon pH and the surface type. Measurements on digested peptides showed that classifications of stability can be made for various regions; these are generally retained as pH is changed. When salt was added to MMC systems, where electrostatic interactions would be minimized, less solvent exposure was seen, implying that it is the cationic moieties, rather than the hydrophobic ligands, which cause greater surface unfolding at low salt concentrations. These results suggest that proteins of lower stability may exhibit unfolding and aggregation during IEC and MMC separations, as they can with hydrophobic interaction chromatography. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Derivatization patterns among starch chain populations assessed by ion-exchange chromatography: a model system approach.

    Science.gov (United States)

    Hong, Jung Sun; Huber, Kerry C

    2015-05-20

    Reaction patterns of wheat starch derivatized with a fluorescent probe (model reaction system) were investigated over the course of a reaction period (0.5, 4, 12, or 24h). Debranched derivatives were fractionated into three populations (Unbound, Bound-1, Bound-2) based on charge density via anion-exchange chromatography, with each ion-exchanged fraction further analyzed by size-exclusion chromatography (refractive index [RI] and fluorescence [FL] detection) to assess proportions and patterns of reaction on amylose (AM) and amylopectin (AP) long (LC), medium (MC), and short (SC) branch chains. Approximately 11-12% of the total chains accounted for 63-75% of the FL recovered in the two bound fractions. FL peaks representing AM, AP-LC, AP-MC, AP-SC, and intermediate material (eluted with AM based on molecular size, but reacted more akin to AP-LC) were monitored over the reaction period. Fractionation behaviors varied amongst starch chains, attributable to the impact of the granule structure on molecular reaction patterns. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Fabrication of electrolytic cell for online post-column electrochemical derivatization in ion chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Wu Shuchao [Department of Chemistry, Xixi Campus, Zhejiang University, Hangzhou 310028, Zhejiang (China); Xu Wei [State Key Laboratory for Diagnosis and Treatment of Infectious Diseases, The First Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou 310028, Zhejiang (China); Yang Bingcheng [School of Pharmacy, East China University of Science and Technology, Shanghai 200237 (China); Ye Mingli [Thermofisher scientific (China), Shanghai 201203 (China); Zhang Peimin [Department of Chemistry, Xixi Campus, Zhejiang University, Hangzhou 310028, Zhejiang (China); Shentu Chao [College of Biology and Environmental Engineering, Zhejiang Shuren University, Hangzhou 310015 (China); Zhu Yan, E-mail: zhuyan@zju.edu.cn [Department of Chemistry, Xixi Campus, Zhejiang University, Hangzhou 310028, Zhejiang (China)

    2012-07-20

    Highlight: Black-Right-Pointing-Pointer An electrolytic cell including ruthenium modified titanium electrode was fabricated. Black-Right-Pointing-Pointer Ion chromatography/electrochemical derivatization/fluorescence detection was developed. Black-Right-Pointing-Pointer Strong oxidation capacity of this EC was obtained by using the Ru/Ti electrode with large surface area. - Abstract: An electrolytic cell (EC), composed of two ruthenium-plated titanium electrodes separated by cation-exchange membranes, was fabricated and evaluated for online postcolumn derivatization in ion chromatography (IC). Folic acid (FA) and methotrexate (MTX) were preliminarily used as prototype analytes to test the performance of EC. After separation by an anion exchange column, FA and MTX, which emit very weak fluorescence when excited, were electrochemically oxidized online in the anode chamber of the EC. The compounds with strong fluorescence, which are oxidation products, were detected by the fluorescence detector. The phosphate buffer solution (100 mM KH{sub 2}PO{sub 4}) served as an optimal eluent for anion exchange chromatographic separation and a suitable supporting electrolyte for electro-oxidation, leading to ideal compatibility between IC separation and the postcolumn electrochemical derivatization. For the presently proposed method, the linear ranges were from 0.01 mg L{sup -1} to 5 mg L{sup -1} for both FA and MTX. The detection limits of FA and MTX were 1.8 and 2.1 {mu}g L{sup -1}, and the relative standard deviations (RSD, n = 7) were 2.9% and 3.6%, respectively. The method was applied for the simultaneous determination of FA and MTX in the plasma of patients being treated for rheumatoid arthritis. The determination of MTX in the urine of the patients of diffuse large B cell lymphoma was also demonstrated.

  16. Modeling of dual gradient elution in ion exchange and mixed-mode chromatography.

    Science.gov (United States)

    Lee, Yi Feng; Schmidt, Michael; Graalfs, Heiner; Hafner, Mathias; Frech, Christian

    2015-10-23

    Protein retention using dual gradient elution in ion exchange- and mixed-mode chromatography can be modeled using the combination of a modified Yamamoto's LGE model and a conversion term to correlate the elution salt concentration and pH at any given gradient slope. Incorporation of the pH dependence of the binding charges into the model also provides some insights on the dual effects of salt and pH in protein-ligand interaction. The fitted thermodynamic parameters (ΔGP(0)/RT, ΔGS(0)/RT, number of charged amino acids involved in binding) of the dual gradient elution data using lysozyme and mAbs on SP Sepharose(®) FF, Eshmuno(®) HCX, and Capto(®) MMC ImpRes were consistent to the results of mono gradient data. This gives rise to an approach to perform thermodynamic modeling of protein retention in ion exchange- and mixed-mode chromatography by combining both salt and pH gradient into a single run of dual gradient elution which will increase time and cost efficiency. The dual gradients used in this study encompassed a wide range of pH (4-8) and NaCl concentrations (0-1M). Curve fits showed that ΔGP(0)/RT is protein type and ligand dependent. ΔGS(0)/RT is strongly dependent on the stationary phase but not the protein. For mAb04 on mixed-mode resin Capto(®) MMC, ΔGS(0)/RT is 5-6 times higher than the result reported for the same protein on cation exchanger Fractogel(®) EMD SO3(-) (S). Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Rapid degradation of zinc oxide nanoparticles by phosphate ions

    Directory of Open Access Journals (Sweden)

    Rudolf Herrmann

    2014-11-01

    Full Text Available Zinc oxide nanoparticles are highly sensitive towards phosphate ions even at pH 7. Buffer solutions and cell culture media containing phosphate ions are able to destroy ZnO nanoparticles within a time span from less than one hour to one day. The driving force of the reaction is the formation of zinc phosphate of very low solubility. The morphology of the zinc oxide particles has only a minor influence on the kinetics of this reaction. Surface properties related to different production methods and the presence and absence of labelling with a perylene fluorescent dye are more important. Particles prepared under acidic conditions are more resistant than those obtained in basic or neutral reaction medium. Surprisingly, the presence of a SiO2 coating does not impede the degradation of the ZnO core. In contrast to phosphate ions, β-glycerophosphate does not damage the ZnO nanoparticles. These findings should be taken into account when assessing the biological effects or the toxicology of zinc oxide nanoparticles.

  18. Analytical characterization of complex, biotechnological feedstocks by pH gradient ion exchange chromatography for purification process development.

    Science.gov (United States)

    Kröner, Frieder; Hanke, Alexander T; Nfor, Beckley K; Pinkse, Martijn W H; Verhaert, Peter D E M; Ottens, Marcel; Hubbuch, Jürgen

    2013-10-11

    The accelerating growth of the market for proteins and the growing interest in new, more complex molecules are bringing new challenges to the downstream process development of these proteins. This results in a demand for faster, more cost efficient, and highly understood downstream processes. Screening procedures based on high-throughput methods are widely applied nowadays to develop purification processes for proteins. However, screening highly complex biotechnological feedstocks, such as complete cell lysates containing target proteins often expressed with a low titre, is still very challenging. In this work we demonstrate a multidimensional, analytical screening approach based on pH gradient ion exchange chromatography (IEC), gel electrophoresis and protein identification via mass spectrometry to rationally characterize a biotechnological feedstock for the purpose of purification process development. With this very simple characterization strategy a two-step purification based on consecutive IEC operations was rapidly laid out for the purification of a diagnostic protein from a cell lysate reaching a purity of ∼80%. The target protein was recombinantly produced using an insect cell expression system. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. Derivatization Ion Chromatography for the Determination of Monoethanolamine in Presence of Hydrazine in PHWR Steam-Water Circuits

    Directory of Open Access Journals (Sweden)

    Ayushi D.

    2011-01-01

    Full Text Available A simple, rapid and accurate method for the determination of monoethanolamine (MEA in PHWR steam-water circuits has been developed. MEA is added in the feed water to provide protection against corrosion while hydrazine is added to scavenge dissolved oxygen. The quantitative determination of MEA in presence of hydrazine was accomplished using derivatization ion chromatography with conductometric detection in nonsuppressed mode. A Metrosep cation 1-2 analytical column and a Metrosep cartridge were used for cation separation. A mixture of 4 mM tartaric acid, 20% acetone and 0.05 mM HNO3 was used as eluent. Acetone in the mobile phase leads to the formation of different derivatives with MEA and hydrazine. The interferences due Na+ and NH4 + were eliminated by adopting a simple pretreatment procedure employing OnGuard-H cartridge. The limit of detection limit of MEA was 0.1 μg mL−1 and the relative standard deviation was 2% for the overall method. The recovery of MEA added was in the range 95%–102%. The method was applied to the determination of MEA in steam generator water samples.

  20. Multi-channel purge and trap system coupled with ion chromatography for the determination of alkylamines in cosmetics.

    Science.gov (United States)

    Zhong, Zhixiong; Li, Gongke; Luo, Zhibin; Zhu, Binghui

    2012-02-17

    A new multi-channel purge and trap system coupled with ion chromatography for the determination of six alkylamines in cosmetics was developed. The proposed method, based on purge and trap of the volatile alkylamines, involved in a miniaturization and multi-channel integration of classical steam distillation and a simple approach for routine labs. The procedure was rapidly achieved within 10 min and the matrix interferences could be effectively eliminated. Sample pretreatment frequency was higher than 40 h(-1). The linear ranges were 0.1-15 mg L(-1) and the detection limits varied from 0.023 to 0.038 mg L(-1). This method was successfully utilized to determine the amounts of alkylamines in cosmetics with recoveries ranging from 80.3 to 105.5% and the relative standard deviations (RSDs) ranging from 0.78 to 7.5%. It was proved to be accurate, time-saving, and suitable for the determination of large numbers of cosmetics in a short time. Copyright © 2011 Elsevier B.V. All rights reserved.

  1. Chemical Speciation Analysis of Sports Drinks by Acid-Base Titrimetry and Ion Chromatography: A Challenging Beverage Formulation Project

    Science.gov (United States)

    Drossman, Howard

    2007-01-01

    Students have standardized a sodium hydroxide solution and analyzed commercially available sports drinks by titrimetric analysis of the triprotic citric acid, dihydrogen phosphate, and dihydrogen citrate and by ion chromatography for chloride, total phosphate and citrate. These experiments are interesting examples of analyzing real-world food and…

  2. The influence of salt type on the retention of bovine serum albumin in ion-exchange chromatography

    DEFF Research Database (Denmark)

    Al-Jibbouri, Sattar

    2007-01-01

    that the mechanism of protein retention in ion-exchange chromatography (IEC) involves interactions between the protein solute, the mobile phase constituents and the stationary phase. The effect of protein activity coefficient in the mobile phase on the protein retention volumes is verified....

  3. Rapid analysis of pharmaceuticals and personal care products in fish plasma micro-aliquots using liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Chen, Fangfang; Gong, Zhiyuan; Kelly, Barry C

    2015-02-27

    A sensitive analytical method based on liquid-liquid extraction (LLE) and liquid chromatography tandem mass spectrometry (LC-MS/MS) was developed for rapid analysis of 11 pharmaceuticals and personal care products (PPCPs) in fish plasma micro-aliquots (∼20μL). Target PPCPs included, bisphenol A, carbamazepine, diclofenac, fluoxetine, gemfibrozil, ibuprofen, naproxen, risperidone, sertraline, simvastatin and triclosan. A relatively quicker and cheaper LLE procedure exhibited comparable analyte recoveries with solid-phase extraction. Rapid separation and analysis of target compounds in fish plasma extracts was achieved by employing a high efficiency C-18 HPLC column (Agilent Poroshell 120 SB-C18, 2.1mm×50mm, 2.7μm) and fast polarity switching, enabling effective monitoring of positive and negative ions in a single 9min run. With the exception of bisphenol A, which exhibited relatively high background contamination, method detection limits of individual PPCPs ranged between 0.15 and 0.69pg/μL, while method quantification limits were between 0.05 and 2.3pg/μL. Mean matrix effect (ME) values ranged between 65 and 156% for the various target analytes. Isotope dilution quantification using isotopically labelled internal surrogates was utilized to correct for signal suppression or enhancement and analyte losses during sample preparation. The method was evaluated by analysis of 20μL plasma micro-aliquots collected from zebrafish (Danio rerio) from a laboratory bioaccumulation study, which included control group fish (no exposure), as well as fish exposed to environmentally relevant concentrations of PPCPs. Using the developed LC-MS/MS based method, concentrations of the studied PPCPs were consistently detected in the low pg/μL (ppb) range. The method may be useful for investigations requiring fast, reliable concentration measurements of PPCPs in fish plasma. In particular, the method may be applicable for in situ contaminant biomonitoring, as well as

  4. Comprehensive analysis of umami compounds by ion-pair liquid chromatography coupled to mass spectrometry.

    Science.gov (United States)

    Coulier, Leon; Bas, Richard; Hekman, Maarten; van der Werff, Bianca J C; Burgering, Maurits; Thissen, Uwe

    2011-09-01

    An ion-pair LC-ESI-MS method was developed capable of analyzing various reported umami or umami-enhancing compounds, including glutamic acid and 5'-ribonucleotides. The method was validated using tomato and potato samples and showed overall good analytical performance with respect to selectivity, detection limit, linearity, and repeatability. The method was applied to various tomato samples resulting in concentrations of glutamic acid and 5'-ribonucleotides that were in good comparison with literature. The methodology might also be used for the discovery of new umami (enhancing) compounds in an untargeted mode. This was to a certain extent demonstrated for tomato samples by correlating all peaks observed with the ion-pair liquid chromatography-mass spectrometry (LC-MS) method to sensory properties using multivariate statistics. This study describes the development and application of a LC-MS method, which can be used to quantify several known umami (enhancing) compounds in various foods. Furthermore, the method might be useful for the discovery of new umami (enhancing) compounds. © 2011 Institute of Food Technologists®

  5. Device to generate high purity hydroxide solution in-line for ion chromatography.

    Science.gov (United States)

    Masunaga, Hiroto; Higo, Yuji; Ishii, Mizuo; Maruyama, Noboru; Yamazaki, Shigeo

    2016-05-06

    Herein, we report a new device that generates a high-purity hydroxide solution in line. The device's container has three compartments that are isolated from each other by two cation exchange (CE) membranes. In each end of the container, an electrode is installed. The three compartments are filled with ion exchange resins. A bipolar boundary is a composite boundary comprising anion- and cation-exchangers. This device has two bipolar boundaries, which are used to separate the location of hydroxide solution generation from the location where water is electrolyzed. Therefore, it can produce high-purity hydroxide solutions that are free from gases and anionic impurities. The hydroxide solution is generated on the basis of an electrokinetic phenomenon at the surfaces of ion-exchange resins and membranes in an electric field; NaOH concentration can be controlled at rates from 0.01 to 100mM per 1mL/min by adjusting the electrical current (0-200mA) applied to the device. As the generated solution is used as an eluent for a suppressed anion chromatography, the electrical conductivity of the effluent from the suppressor is as low as that of ultra-pure water. Thus, the noise of the base-line electrical conductivity is improved, and so the detection limit of anions on the sub-ng/mL order can be achieved. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Continuous desalting of refolded protein solution improves capturing in ion exchange chromatography: A seamless process.

    Science.gov (United States)

    Walch, Nicole; Jungbauer, Alois

    2017-06-01

    Truly continuous biomanufacturing processes enable an uninterrupted feed stream throughout the whole production without the need for holding tanks. We have utilized microporous anion and cation exchangers into which only salts, but not proteins, can penetrate into the pores for desalting of protein solutions, while diafiltration or dilution is usually employed for feed adjustments. Anion exchange and cation exchange chromatography columns were connected in series to remove both anions and cations. To increase operation performance, a continuous process was developed comprised of four columns. Continuous mode was achieved by staggered cycle operation, where one set of columns, consisting of one anion exchange and one cation exchange column, was loaded during the regeneration of the second set. Refolding, desalting and subsequent ion exchange capturing with a scFv as the model protein was demonstrated. The refolding solution was successfully desalted resulting in a consistent conductivity below 0.5 mS/cm from initial values of 10 to 11 mS/cm. With continuous operation process time could be reduced by 39% while productivity was increased to 163% compared to batch operation. Desalting of the protein solution resulted in up to 7-fold higher binding capacities in the subsequent ion exchange capture step with conventional protein binding resins. © 2017 The Authors. Biotechnology Journal published by WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Simultaneous Proteomic Discovery and Targeted Monitoring using Liquid Chromatography, Ion Mobility Spectrometry, and Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Burnum-Johnson, Kristin E.; Nie, Song; Casey, Cameron P.; Monroe, Matthew E.; Orton, Daniel J.; Ibrahim, Yehia M.; Gritsenko, Marina A.; Clauss, Therese R. W.; Shukla, Anil K.; Moore, Ronald J.; Purvine, Samuel O.; Shi, Tujin; Qian, Weijun; Liu, Tao; Baker, Erin S.; Smith, Richard D.

    2016-09-25

    Current proteomics approaches are comprised of both broad discovery measurements as well as more quantitative targeted measurements. These two different measurement types are used to initially identify potentially important proteins (e.g., candidate biomarkers) and then enable improved quantification for a limited number of selected proteins. However, both approaches suffer from limitations, particularly the lower sensitivity, accuracy, and quantitation precision for discovery approaches compared to targeted approaches, and the limited proteome coverage provided by targeted approaches. Herein, we describe a new proteomics approach that allows both discovery and targeted monitoring (DTM) in a single analysis using liquid chromatography, ion mobility spectrometry and mass spectrometry (LC-IMS-MS). In DTM, heavy labeled peptides for target ions are spiked into tryptic digests and both the labeled and unlabeled peptides are broadly detected using LC-IMS-MS instrumentation, allowing the benefits of discovery and targeted approaches. To understand the possible improvement of the DTM approach, it was compared to LC-MS broad measurements using an accurate mass and time tag database and selected reaction monitoring (SRM) targeted measurements. The DTM results yielded greater peptide/protein coverage and a significant improvement in the detection of lower abundance species compared to LC-MS discovery measurements. DTM was also observed to have similar detection limits as SRM for the targeted measurements indicating its potential for combining the discovery and targeted approaches.

  8. Rapid evaluation of ion thruster lifetime using optical emission spectroscopy

    Science.gov (United States)

    Rock, B. A.; Parsons, M. L.; Mantenieks, M. A.

    1985-01-01

    A major life-limiting phenomenon of electric thrusters is the sputter erosion of discharge chamber components. Thrusters for space propulsion are required to operate for extended periods of time, usually in excess of 10,000 hr. Lengthy and very costly life-tests in high-vacuum facilities have been required in the past to determine the erosion rates of thruster components. Alternative methods for determining erosion rates which can be performed in relatively short periods of time at considerably lower costs are studied. An attempt to relate optical emission intensity from an ion bombarded surface (screen grid) to the sputtering rate of that surface is made. The model used a kinetic steady-state (KSS) approach, balancing the rates of population and depopulation of ten low-lying excited states of the sputtered molybdenum atom (MoI) with those of the ground state to relate the spectral intensities of the various transitions of the MoI to the population densities. Once this is accomplished, the population density can be related to the sputting rate of the target. Radiative and collisional modes of excitation and decay are considered. Since actual data has not been published for MoI excitation rate and decay constants, semiempirical equations are used. The calculated sputtering rate and intensity is compared to the measured intensity and sputtering rates of the 8 and 30 cm ion thrusters.

  9. Rapid quantification of ionophores in feeds by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Huang, Min; Rumbeiha, Wilson K; Braselton, W Emmett; Johnson, Margaret

    2011-09-01

    Ionophores are widely used in veterinary medicine as coccidiostats and for improving nutrient utilization in livestock production. Because of widespread use, ionophores sometimes cause poisoning in livestock. Quantifying concentration of these compounds in feeds for diagnostic purposes is needed. A method with a single step of solvent extraction was developed for rapid simultaneous quantification of monensin, lasalocid, salinomycin, and narasin in feeds by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The ionophores were extracted using methanol:water (90:10). With the high specificity and high sensitivity of tandem mass spectrometry, the extract was introduced for measurement without further processing. The effect of particle size of feeds on extraction efficiency was also investigated. It was found that feeds passing through a 1-mm filter or sieve show better quantitative extraction. Nigericin was used as internal standard for the measurement. The method was validated by fortification of the selected ionophore compounds in horse feed at different concentrations. The typical recovery rate was 69-122%. Meanwhile, various interlaboratory proficiency test samples of different matrices were also quantified as part of the procedure for method validation. A good agreement was found between results and the suggested values. The method is very sensitive, with detection limits between 0.018 µg/g and 0.056 µg/g for the compounds tested. Results showed that the lower limit of quantification was 0.2 µg/g for the ionophore compounds, which is much lower than the contents of the ionophores in medicated feeds, which is generally approximately 10-100 µg/g feed.

  10. Sequential determination of fat- and water-soluble vitamins in Rhodiola imbricata root from trans-Himalaya with rapid resolution liquid chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Tayade, Amol B; Dhar, Priyanka; Kumar, Jatinder; Sharma, Manu; Chaurasia, Om P; Srivastava, Ravi B

    2013-07-30

    A rapid method was developed to determine both types of vitamins in Rhodiola imbricata root for the accurate quantification of free vitamin forms. Rapid resolution liquid chromatography/tandem mass spectrometry (RRLC-MS/MS) with electrospray ionization (ESI) source operating in multiple reactions monitoring (MRM) mode was optimized for the sequential analysis of nine water-soluble vitamins (B1, B2, two B3 vitamins, B5, B6, B7, B9, and B12) and six fat-soluble vitamins (A, E, D2, D3, K1, and K2). Both types of vitamins were separated by ion-suppression reversed-phase liquid chromatography with gradient elution within 30 min and detected in positive ion mode. Deviations in the intra- and inter-day precision were always below 0.6% and 0.3% for recoveries and retention time. Intra- and inter-day relative standard deviation (RSD) values of retention time for water- and fat-soluble vitamin were ranged between 0.02-0.20% and 0.01-0.15%, respectively. The mean recoveries were ranged between 88.95 and 107.07%. Sensitivity and specificity of this method allowed the limits of detection (LOD) and limits of quantitation (LOQ) of the analytes at ppb levels. The linear range was achieved for fat- and water-soluble vitamins at 100-1000 ppb and 10-100 ppb. Vitamin B-complex and vitamin E were detected as the principle vitamins in the root of this adaptogen which would be of great interest to develop novel foods from the Indian trans-Himalaya. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. Determination of dissolved bromate in drinking water by ion chromatography and post column reaction: interlaboratory study.

    Science.gov (United States)

    Cordeiro, Fernando; Robouch, Piotr; de la Calle, Maria Beatriz; Emteborg, Håkan; Charoud-Got, Jean; Schmitz, Franz

    2011-01-01

    A collaborative study, International Evaluation Measurement Programme-25a, was conducted in accordance with international protocols to determine the performance characteristics of an analytical method for the determination of dissolved bromate in drinking water. The method should fulfill the analytical requirements of Council Directive 98/83/EC (referred to in this work as the Drinking Water Directive; DWD). The new draft standard method under investigation is based on ion chromatography followed by post-column reaction and UV detection. The collaborating laboratories used the Draft International Organization for Standardization (ISO)/Draft International Standard (DIS) 11206 document. The existing standard method (ISO 15061:2001) is based on ion chromatography using suppressed conductivity detection, in which a preconcentration step may be required for the determination of bromate concentrations as low as 3 to 5 microg/L. The new method includes a dilution step that reduces the matrix effects, thus allowing the determination of bromate concentrations down to 0.5 microg/L. Furthermore, the method aims to minimize any potential interference of chlorite ions. The collaborative study investigated different types of drinking water, such as soft, hard, and mineral water. Other types of water, such as raw water (untreated), swimming pool water, a blank (named river water), and a bromate standard solution, were included as test samples. All test matrixes except the swimming pool water were spiked with high-purity potassium bromate to obtain bromate concentrations ranging from 1.67 to 10.0 microg/L. Swimming pool water was not spiked, as this water was incurred with bromate. Test samples were dispatched to 17 laboratories from nine different countries. Sixteen participants reported results. The repeatability RSD (RSD(r)) ranged from 1.2 to 4.1%, while the reproducibility RSD (RSDR) ranged from 2.3 to 5.9%. These precision characteristics compare favorably with those of ISO

  12. Rapid analysis of the interactions between drugs and human serum albumin (HSA) using high-performance affinity chromatography (HPAC).

    Science.gov (United States)

    Kim, Hee Seung; Wainer, Irving W

    2008-07-01

    This study used a combination of zonal elution and frontal affinity chromatography on immobilized human serum albumin (HSA) high-performance affinity chromatography (HPAC) column to examine the association constants of various compounds that have been studied by equilibrium dialysis or ultra filtration. A standard plot was generated from retention factors of reference compounds using zonal elution chromatography against association constants of reference compounds using frontal affinity chromatography. The linear relationship was established (r2=0.9993) between retention factors and association constants of reference compounds. This standard plot was later used for rapid determination of association constants of various drugs which show low to medium binding affinity to HSA. Association constants of those drugs from this study were compared to that of more generally used methods (i.e., equilibrium dialysis or ultra filtration) from literature and resulted in a relatively high correlation (r2=0.945) value. This combination of zonal elution and frontal affinity chromatography method for determining association constants showed several advantages against traditional methods. Depending on drugs of interest, an association constant of drug to HSA can be measured as fast as 1.5 min. Other notable advantages include an ease of automation and its ability to distinguish association constants of chiral compounds at the same time. The same approach could be used for studying interaction of other drugs and proteins and should further improve overall drug screening process.

  13. Chloride analysis in magnesium metal using ion chromatography with conductometric detection.

    Science.gov (United States)

    Kumar, Sangita D; Tripathi, V S; Shenoy, Niyoti; Maiti, B

    2004-08-13

    A simple, rapid and accurate method for the determination of chloride in magnesium metal has been developed. The quantitative determination of chloride was accomplished by anion exchange chromatography with conductometric determination. A Metrosep Anion Dual 2 analytical column connected in series with a Metrosep RP guard column was used for chloride separation. A solution containing a mixture of 1.3 mM Na2CO3 and 2 mM NaHCO3 was used as eluent. The method requires a sample dissolution using nitric acid. The limit of detection for the determination of chloride is 50 mg kg(-1) and the relative standard deviation was 5% for the overall method. The recovery of chloride added was 99-102%. No interference was observed from either the closely eluting "system peak" or the nitrate peak in the determination of chloride.

  14. [High speed separation and quantitation of Ralstonia solanacearum of different virulence using high performance ion exchange chromatography].

    Science.gov (United States)

    Lin, Juan; Ma, Cheng; Liu, Shutao; Wu, Lingling; Rao, Pingfan

    2007-01-01

    High performance ion exchange chromatography coupled with laser light scattering instrument was employed for the rapid separation and quantitation of Ralstonia solanacearum of different virulence. The pure culture of Ralstonia solanacearum was successfully separated into three characteristic fractions. Each fraction was collected and inoculated onto 2,3,5-triphenyltetrazolium chloride (TTC) plates to identify its virulence. The shapes and colors of the colonies were imaged, and the average attenuation index (attenuation index = red spot diameter of colony/total colony diameter) of ten colonies of each fraction was carefully determined. Furthermore, each fraction was inoculated into SPA liquid media at 30 degrees C with shaking (200 r/min) for 48 h, the cells were harvested, suspended at a density of 1.2 x 10(9) cfu/mL, and applied to infect tomato tissue culture plantlets using leaf-cutting method. The infection mortality of the tomato tissue culture plantlets was recorded from 1 to 9 days after inoculation. The results showed that the virulences of each fraction were different on the basis of attenuation index and infection mortality. The virulence of peak 3 fraction was the strongest. On the contrary, the virulence of peak 1 fraction was the weakest. In addition, the linear relationships between different injection volumes (1 - 180 microL) and their peak areas were investigated. The linearity was good within the range of the bacterial number of 9 x 10(6) - 9 x 10(8) (r = 0.99). This method can be potentially used as a novel tool for the rapid separation and quantitation of Ralstonia solanacearum of different virulences.

  15. Determination of Inorganic Cations and Anions in Chitooligosaccharides by Ion Chromatography with Conductivity Detection.

    Science.gov (United States)

    Cao, Lidong; Li, Xiuhuan; Fan, Li; Zheng, Li; Wu, Miaomiao; Zhang, Shanxue; Huang, Qiliang

    2017-02-22

    Chitooligosaccharides (COSs) are a promising drug candidate and food ingredient because they are innately biocompatible, non-toxic, and non-allergenic to living tissues. Therefore, the impurities in COSs must be clearly elucidated and precisely determined. As for COSs, most analytical methods focus on the determination of the average degrees of polymerization (DPs) and deacetylation (DD), as well as separation and analysis of the single COSs with different DPs. However, little is known about the concentrations of inorganic cations and anions in COSs. In the present study, an efficient and sensitive ion chromatography coupled with conductivity detection (IC-CD) for the determination of inorganic cations Na⁺, NH₄⁺, K⁺, Mg2+, Ca2+, and chloride, acetate and lactate anions was developed. Detection limits were 0.01-0.05 μM for cations and 0.5-0.6 μM for anions. The linear range was 0.001-0.8 mM. The optimized analysis was carried out on IonPac CS12A and IonPac AS12A analytical column for cations and anions, respectively, using isocratic elution with 20 mM methanesulfonic acid and 4 mM sodium hydroxide aqueous solution as the mobile phase at a 1.0 mL/min flow rate. Quality parameters, including precision and accuracy, were fully validated and found to be satisfactory. The fully validated IC-CD method was readily applied for the quantification of various cations and anions in commercial COS technical concentrate.

  16. An integrated strategy for rapid discovery and identification of the sequential piperine metabolites in rats using ultra high-performance liquid chromatography/high resolution mass spectrometery.

    Science.gov (United States)

    Shang, Zhanpeng; Cai, Wei; Cao, Yanfeng; Wang, Fei; Wang, Zhibin; Lu, Jianqiu; Zhang, Jiayu

    2017-11-30

    Piperine, one of the major bioactive constituents isolated from natural flavorings and medicinal-culinary herbs, possesses various biological activities. In the present study, an integrated strategy based on ultra high-performance liquid chromatography/high resolution mass spectrometry was established to reveal piperine metabolism in rats. First of all, post-acquisition data-mining methods, including high resolution extracted ion chromatograms (HREICs) and multiple mass defect filtering (MMDF), were used to screen piperine metabolite candidates in a full-scan HRMS(1) level. Then, parent ion list-dynamic exclusion coupled with data-dependent data-acquisition method was utilized to acquire MS(n) datasets. In addition, the established reverse molecular assembly (RMA) approach based on paired diagnostic product ions (pDPIs) coupled with neutral loss fragments (NLFs) was used to ascertain and identify the major-to-trace piperine metabolites efficiently. And then, the calculated ClogP values were utilized to distinguish the positional isomers. As a result, a total of 148 piperine metabolites were detected and characterized tentatively. The results demonstrated that piperine mainly underwent hydrogenation, dehydrogenation, hydroxylation, glucuronide conjugation, sulfate conjugation, ring-cleavage, and their composite reactions. Our results not only provided novel and useful data to better understand the safety, toxicity and efficacy of this potential therapeutic agent, but also indicated that the proposed strategy was reliable for a rapid discovery and identification drug-related constituents in vivo. Copyright © 2017. Published by Elsevier B.V.

  17. Probing gunshot residue, sweat and latent human fingerprints with capillary-scale ion chromatography and suppressed conductivity detection.

    Science.gov (United States)

    Gilchrist, Elizabeth; Smith, Norman; Barron, Leon

    2012-04-07

    An investigation into capillary-scale ion chromatography with suppressed conductivity detection is presented for the identification of low molecular weight anions in samples of limited size. Both particle-packed and polymer monolith capillary ion exchange resins were compared with respect to their chromatographic efficiencies, operating back-pressures and thermal selectivities. Using a multistep hydroxide gradient, it was possible to separate a large selection of inorganic and organic anions in gunshot residue into fingerprints of a firer. Similarly, identification of direct contact with a black powder substitute is presented via analysis of latent fingermarks. To the best of our knowledge, this represents the first study of sweat and fingerprints using capillary-scale suppressed ion chromatography.

  18. Use of ion-exchange chromatography and hydrophobic interaction chromatography in the preparation and recovery of polyethylene glycol-linked proteins.

    Science.gov (United States)

    Seely, J E; Richey, C W

    2001-01-26

    Cation- and anion-exchange chromatography can be used to purify a polyethylene glycol-linked protein dimer (PEG dimer) made with M, 20 000 PEG bis-vinylsulfone, even when there are no net charge differences between the components that are being separated. The retention time on ion-exchange generally is inversely proportional to the PEG:protein ratio (on a mass basis). One of the biggest challenges in developing the process for making this PEG dimer was the quality of the PEG linker. Reversed-phase HPLC can be used to determine both size heterogeneity and the degree of end-group activation of Mr 20 000 PEG bis-vinylsulfone. In addition, we have found that hydrophobic interaction chromatography can be used make more size homogeneous preparations of Mr 20000 PEG bis-vinylsulfone, which significantly increased the recovery of the PEG dimer.

  19. Comprehensive analysis of pharmaceutical products using simultaneous mixed-mode (ion-exchange/reversed-phase) and hydrophilic interaction liquid chromatography.

    Science.gov (United States)

    Kazarian, Artaches A; Nesterenko, Pavel N; Soisungnoen, Phimpha; Burakham, Rodjana; Srijaranai, Supalax; Paull, Brett

    2014-08-01

    Liquid chromatographic assays were developed using a mixed-mode column coupled in sequence with a hydrophilic interaction liquid chromatography column to allow the simultaneous comprehensive analysis of inorganic/organic anions and cations, active pharmaceutical ingredients, and excipients (carbohydrates). The approach utilized dual sample injection and valve-mediated column switching and was based upon a single high-performance liquid chromatography gradient pump. The separation consisted of three distinct sequential separation mechanisms, namely, (i) ion-exchange, (ii) mixed-mode interactions under an applied dual gradient (reversed-phase/ion-exchange), and (iii) hydrophilic interaction chromatography. Upon first injection, the Scherzo SS C18 column (Imtakt) provided resolution of inorganic anions and cations under isocratic conditions, followed by a dual organic/salt gradient to elute active pharmaceutical ingredients and their respective organic counterions and potential degradants. At the top of the mixed-mode gradient (high acetonitrile content), the mobile phase flow was switched to a preconditioned hydrophilic interaction liquid chromatography column, and the standard/sample was reinjected for the separation of hydrophilic carbohydrates, some of which are commonly known excipients in drug formulations. The approach afforded reproducible separation and resolution of up to 23 chemically diverse solutes in a single run. The method was applied to investigate the composition of commercial cough syrups (Robitussin®), allowing resolution and determination of inorganic ions, active pharmaceutical ingredients, excipients, and numerous well-resolved unknown peaks. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Adsorption of endotoxins on Ca2+ -iminodiacetic acid by metal ion affinity chromatography.

    Science.gov (United States)

    Lopes, André Moreni; Romeu, Jorge Sánchez; Meireles, Rolando Páez; Perera, Gabriel Marquez; Morales, Rolando Perdomo; Pessoa, Adalberto; Cárdenas, Lourdes Zumalacárregui

    2012-11-01

    Endotoxins (also known as lipopolysaccharides (LPS)) are undesirable by-products of recombinant proteins, purified from Escherichia coli. LPS can be considered stable under a wide range of temperature and pH, making their removal one of the most difficult tasks in downstream processes during protein purification. The inherent toxicity of LPS makes their removal an important step for the application of these proteins in several biological assays and for a safe parenteral administration. Immobilized metal affinity chromatography (IMAC) enables the affinity interactions between the metal ions (immobilized on the support through the chelating compound) and the target molecules, thus enabling high-efficiency separation of the target molecules from other components present in a mixture. Affinity chromatography is applied with Ca2+ -iminodiacetic acid (IDA) to remove most of the LPS contaminants from the end product (more than 90%). In this study, the adsorption of LPS on an IDA-Ca2+ was investigated. The adsorption Freundlich isotherm of LPS-IDA-Ca2+ provides a theoretical basis for LPS removal. It was found that LPS is bound mainly by interactions between the phosphate group in LPS and Ca2+ ligands on the beads. The factors such as pH (4.0 or 5.5) and ionic strength (1.0 mol/L) are essential to obtain effective removal of LPS for contaminant levels between endotoxin' concentration values less than 100 EU/mL and 100 000 EU/mL. This new protocol represents a substantial advantage in time, effort, and production costs.

  1. [Screening and confirmation of 24 hormones in cosmetics by ultra high performance liquid chromatography-linear ion trap/orbitrap high resolution mass spectrometry].

    Science.gov (United States)

    Li, Zhaoyong; Wang, Fengmei; Niu, Zengyuan; Luo, Xin; Zhang, Gang; Chen, Junhui

    2014-05-01

    A method of ultra high performance liquid chromatography-linear ion trap/orbitrap high resolution mass spectrometry (UPLC-LTQ/Orbitrap MS) was established to screen and confirm 24 hormones in cosmetics. Various cosmetic samples were extracted with methanol. The extract was loaded onto a Waters ACQUITY UPLC BEH C18 column (50 mm x 2.1 mm, 1.7 microm) using a gradient elution of acetonitrile/water containing 0.1% (v/v) formic acid for the separation. The accurate mass of quasi-molecular ion was acquired by full scanning of electrostatic field orbitrap. The rapid screening was carried out by the accurate mass of quasi-molecular ion. The confirmation analysis for targeted compounds was performed with the retention time and qualitative fragments obtained by data dependent scan mode. Under the optimal conditions, the 24 hormones were routinely detected with mass accuracy error below 3 x 10(-6) (3 ppm), and good linearities were obtained in their respective linear ranges with correlation coefficients higher than 0.99. The LODs (S/N = 3) of the 24 compounds were hormones in 50 cosmetic samples. The results demonstrate that the method is a useful tool for the rapid screening and identification of the hormones in cosmetics.

  2. Rapid discrimination of slimming capsules based on illegal additives by electronic nose and flash gas chromatography.

    Science.gov (United States)

    Xia, Zhenzhen; Cai, Wensheng; Shao, Xueguang

    2015-02-01

    The discrimination of counterfeit and/or illegally manufactured medicines is an important task in the pharmaceutical industry for pharmaceutical safety. In this study, 22 slimming capsule samples with illegally added sibutramine and phenolphthalein were analyzed by electronic nose and flash gas chromatography. To reveal the difference among the different classes of samples, principal component analysis and linear discriminant analysis were employed to analyze the data acquired from electronic nose and flash gas chromatography, respectively. The samples without illegal additives can be discriminated from the ones with illegal additives by using electronic nose or flash gas chromatography data individually. To improve the performance of classification, a data fusion strategy was applied to integrate the data from electronic nose and flash gas chromatography data into a single model. The results show that the samples with phenolphthalein, sibutramine and both can be classified well by using fused data. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Rapid Buffer and Ligand Screening for Affinity Chromatography by Multiplexed Surface Plasmon Resonance Imaging

    NARCIS (Netherlands)

    Geuijen, K.P.M.; Wijk-Basten, van Danielle E.J.W.; Egging, Davis F.; Schasfoort, Richard B.M.; Eppink, M.H.M.

    2017-01-01

    Protein purifications are often based on the principle of affinity chromatography, where the protein of interest selectively binds to an immobilized ligand. The development of affinity purification requires selecting proper wash and elution conditions. In recent years, miniaturization of the

  4. Separation of seven arsenic species by ion-pair and ion-exchange high performance liquid chromatography

    DEFF Research Database (Denmark)

    Larsen, Erik Huusfeldt; Hansen, Sven Hedegaard

    1992-01-01

    Arsenite, arsenate, monomethylarsonate, dimethylarsinate, arsenobetaine, arsenocholine and the tetramethylarsonium ion were subjected to ion-exchange and ion-pair reversed phase HPLC. The ion exchange method was superior in selectivity and time of analysis for the arsenic anions. The ammonium ions...... used for the ion-pair method only resulted in separation of some of the anionic arsenic compounds. Flame atomic absorption spectrometry was used for on-line arsenic-specific detection....

  5. Affinity chromatography of polyhistidine tagged enzymes. New dextran-coated immobilized metal ion affinity chromatography matrices for prevention of undesired multipoint adsorptions.

    Science.gov (United States)

    Mateo, C; Fernandez-Lorente, G; Pessela, B C; Vian, A; Carrascosa, A V; Garcia, J L; Fernandez-Lafuente, R; Guisan, J M

    2001-04-27

    New immobilized metal ion affinity chromatography (IMAC) matrices containing a high concentration of metal-chelate moieties and completely coated with inert flexible and hydrophilic dextrans are here proposed to improve the purification of polyhistidine (poly-His) tagged proteins. The purification of an interesting recombinant multimeric enzyme (a thermoresistant beta-galactosidase from Thermus sp. strain T2) has been used to check the performance of these new chromatographic media. IMAC supports with a high concentration (and surface density) of metal chelate groups promote a rapid adsorption of poly-His tagged proteins during IMAC. However, these supports also favor the promotion of undesirable multi-punctual adsorptions and problems may arise for the simple and effective purification of poly-His tagged proteins: (a) more than 30% of the natural proteins contained in crude extracts from E. coli become adsorbed, in addition to our target recombinant protein, on these IMAC supports via multipoint weak adsorptions; (b) the multimeric poly-His tagged enzyme may become adsorbed via several poly-His tags belonging to different subunits. In this way, desorption of the pure enzyme from the support may become quite difficult (e.g., it is not fully desorbed from the support even using 200 mM of imidazole). The coating of these IMAC supports with dextrans greatly reduces these undesired multi-point adsorptions: (i) less than 2% of natural proteins contained in crude extracts are now adsorbed on these novel supports; and (ii) the target multimeric enzyme may be fully desorbed from the support using 60 mM imidazole. In spite of this dramatic reduction of multi-point interactions, this dextran coating hardly affects the rate of the one-point adsorption of poly-His tagged proteins (80% of the rate of adsorption compared to uncoated supports). Therefore, this dextran coating of chromatographic matrices seems to allow the formation of strong one-point adsorptions that involve

  6. Factors influencing the separation of oligonucleotides using reversed-phase/ion-exchange mixed-mode high performance liquid chromatography columns.

    Science.gov (United States)

    Biba, Mirlinda; Jiang, Eileen; Mao, Bing; Zewge, Daniel; Foley, Joe P; Welch, Christopher J

    2013-08-23

    New mixed-mode columns consisting of reversed-phase and ion-exchange separation modes were evaluated for the analysis of short RNA oligonucleotides (∼20mers). Conventional analysis for these samples typically involves using two complementary methods: strong anion-exchange liquid chromatography (SAX-LC) for separation based on charge, and ion-pair reversed-phase liquid chromatography (IP-RPLC) for separation based on hydrophobicity. Recently introduced mixed-mode high performance liquid chromatography (HPLC) columns combine both reversed-phase and ion-exchange modes, potentially offering a simpler analysis by combining the benefits of both separation modes into a single method. Analysis of a variety of RNA oligonucleotide samples using three different mixed-mode stationary phases showed some distinct benefits for oligonucleotide separation and analysis. When using these mixed-mode columns with typical IP-RPLC mobile phase conditions, such as ammonium acetate or triethylammonium acetate as the primary ion-pair reagent, the separation was mainly based on the IP-RPLC mode. However, when changing the mobile phase conditions to those more typical for SAX-LC, such as salt gradients with NaCl or NaBr, very different separation patterns were observed due to mixed-mode interactions. In addition, the Scherzo SW-C18 and SM-C18 columns with sodium chloride or sodium bromide salt gradients also showed significant improvements in peak shape. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. Direct analysis of pharmaceutical formulations from non-bonded reversed-phase thin-layer chromatography plates by desorption electrospray ionisation ion mobility mass spectrometry.

    Science.gov (United States)

    Harry, Emma L; Reynolds, James C; Bristow, Anthony W T; Wilson, Ian D; Creaser, Colin S

    2009-09-01

    The direct analysis of pharmaceutical formulations and active ingredients from non-bonded reversed-phase thin layer chromatography (RP-TLC) plates by desorption electrospray ionisation (DESI) combined with ion mobility mass spectrometry (IM-MS) is reported. The analysis of formulations containing analgesic (paracetamol), decongestant (ephedrine), opiate (codeine) and stimulant (caffeine) active pharmaceutical ingredients is described, with and without chromatographic development to separate the active ingredients from the excipient formulation. Selectivity was enhanced by combining ion mobility and mass spectrometry to characterise the desorbed gas-phase analyte ions on the basis of mass-to-charge ratio (m/z) and gas-phase ion mobility (drift time). The solvent composition of the DESI spray using a step gradient was varied to optimise the desorption of active pharmaceutical ingredients from the RP-TLC plates. The combined RP-TLC/DESI-IM-MS approach has potential as a rapid and selective technique for pharmaceutical analysis by orthogonal gas-phase electrophoretic and mass-to-charge separation. Copyright (c) 2009 John Wiley & Sons, Ltd.

  8. Comparison of Gas Chromatography-Mass Spectrometry and Gas Chromatography-Tandem Mass Spectrometry with Electron Ionization and Negative-Ion Chemical Ionization for Analyses of Pesticides at Trace Levels in Atmospheric Samples

    OpenAIRE

    Renata Raina; Patricia Hall

    2008-01-01

    A comparison of detection limits of gas chromatography-mass spectrometry (GC-MS) in selected ion monitoring (SIM) with gas chromatography-tandem mass spectrometry (GC-MS/MS) in selected reaction monitoring (SRM) mode with both electron ionization (EI) and negative-ion chemical ionization (NCI) are presented for over 50 pesticides ranging from organochlorines (OCs), organophosphorus pesticides (OPs) and pre-emergent herbicides used in the Canadian prairies (triallate, trifluralin, ethalflurali...

  9. Separation of 1,3-Propanediol from Aqueous Solutions by Ion Exchange Chromatography

    Directory of Open Access Journals (Sweden)

    Rukowicz Beata

    2014-06-01

    Full Text Available 1,3-propanediol is a promising monomer with many applications and can be produced by bioconversion of renewable resources. The separation of this product from fermentation broth is a difficult task. In this work, the application of cation exchange resin for the separation of 1,3-propanediol from model aqueous solution was examined. The best effect of separation of 1,3-propanediol from glycerol using sorption method was obtained for H+ resin form, although the observed partition coefficient of 1,3-propanediol was low. On the basis of the results of the sorption of 1,3-propanediol, the ionic forms of the resin were selected and used in the next experiments (H+, Ca2+, Ag+, Na+, Pb2+, Zn2+. The best results in ion exchange chromatography were obtained for cation exchange resin in H+ and Ca2+ form. The use of smaller particle size of resin and a longer length of the column allows to obtain better separation of mixtures.

  10. Electrostatic contributions to protein retention in ion-exchange chromatography. 1. Cytochrome C variants.

    Science.gov (United States)

    Yao, Yan; Lenhoff, Abraham M

    2004-11-15

    Among the factors that modulate protein interactions, several protein structural properties, such as size, shape, and charge distribution, may play significant roles. In this work, we investigate the influence of protein structure on binding in ion-exchange chromatography, in which electrostatic interactions are dominant. Chromatographic experiments show separation of cytochrome c variants with a limited number of sequence differences to be feasible. To probe the molecular basis for this behavior, protein-adsorbent electrostatic interactions were modeled in the context of continuum electrostatics accounting for the full 3D protein structure. Protein retention was modeled by averaging over all protein-adsorbent configurations using the full accessible surface of the protein. The electrostatic interaction free energy distribution shows that configurations in which numerous positive protein charges are close to the cation exchanger functional groups produce the most favorable binding. The calculated binding equilibrium constant, found by averaging over the full 3D configurational space, captures the chromatographic differentiation of closely related cytochrome c variants. To obviate the need for full sampling of protein configurations, calculations of interaction free energies at short protein-adsorbent separation distances or of protein surface potentials were found to yield reasonable semiquantitative descriptions of the retention trends.

  11. Chromatography of proteins on charge-variant ion exchangers and implications for optimizing protein uptake rates.

    Science.gov (United States)

    Langford, John F; Xu, Xuankuo; Yao, Yan; Maloney, Sean F; Lenhoff, Abraham M

    2007-09-07

    Intraparticle transport of proteins usually represents the principal resistance controlling their uptake in preparative separations. In ion-exchange chromatography two limiting models are commonly used to describe such uptake: pore diffusion, in which only free protein in the pore lumen contributes to transport, and homogeneous diffusion, in which the transport flux is determined by the gradient in the total protein concentration, free or adsorbed. Several studies have noted a transition from pore to homogeneous diffusion with increasing ionic strength in some systems, and here we investigate the mechanistic basis for this transition. The studies were performed on a set of custom-synthesized methacrylate-based strong cation exchangers differing in ligand density into which uptake of two proteins was examined using confocal microscopy and frontal loading experiments. We find that the transition in uptake mechanism occurs in all cases studied, and generally coincides with an optimum in the dynamic binding capacity at moderately high flow rates. The transition appears to occur when protein-surface attraction is weakened sufficiently, and this is correlated with the isocratic retention factor k' for the system of interest: the transition occurs in the vicinity of k' approximately 3000. This result, which may indicate that adsorption is sufficiently weak to allow the protein to diffuse along or near the surface, provides a predictive basis for optimizing preparative separations using only isocratic retention data.

  12. Anionic forensic signatures for sample matching of potassium cyanide using high performance ion chromatography and chemometrics.

    Science.gov (United States)

    Fraga, Carlos G; Farmer, Orville T; Carman, April J

    2011-01-30

    Potassium cyanide was used as a model toxicant to determine the feasibility of using anionic impurities as a forensic signature for matching cyanide salts back to their source. In this study, portions of eight KCN stocks originating from four countries were separately dissolved in water and analyzed by high performance ion chromatography (HPIC) using an anion exchange column and conductivity detection. Sixty KCN aqueous samples were produced from the eight stocks and analyzed for 11 anionic impurities. Hierarchal cluster analysis and principal component analysis were used to demonstrate that KCN samples cluster according to source based on the concentrations of their anionic impurities. The Fisher-ratio method and degree-of-class separation (DCS) were used for feature selection on a training set of KCN samples in order to optimize sample clustering. The optimal subset of anions needed for sample classification was determined to be sulfate, oxalate, phosphate, and an unknown anion named unk5. Using K-nearest neighbors (KNN) and the optimal subset of anions, KCN test samples from different KCN stocks were correctly determined to be manufactured in the United States. In addition, KCN samples from stocks manufactured in Belgium, Germany, and the Czech Republic were all correctly matched back to their original stocks because each stock had a unique anionic impurity profile. The application of the Fisher-ratio method and DCS for feature selection improved the accuracy and confidence of sample classification by KNN. Copyright © 2010 Elsevier B.V. All rights reserved.

  13. A process for separating acid-sugar mixtures using ion exclusion chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Hester, R.D.; Hartfield, S.W. [University of Southern Mississippi, Hattiesburg, MS (United States); Farina, G.E. [Tennessee Valley Authority, Muscle Shoals, AL (United States)

    1994-10-01

    Work using a low-temperature concentrated sulfuric acid hydrolysis process to convert the cellulosic fraction of corn stover to monomeric sugars demonstrated the high conversion efficiencies possible with that process. The TVA work also confirmed the need for a cost-effective acid-sugar separation process. A preparative-scale ion-exclusion chromatography (IEC) system was designed, constructed, and tested with a variety of synthetic solutions and actual hydrolyzates. Although significant dispersion was observed initially, design changes were effective in minimizing this phenomenon. Data collected during the operation of the preparative-scale system were used in the design and construction of an IEC miniplant capable of processing larger volumes of synthetic solutions or hydrolyzates and in the design of an extraction-assisted IEC system. The data were also used to assess the viability of a continuous feed IEC system. This paper includes a discussion of the IEC process, provides overall material balances for various IEC process scenarios, and presents a discussion on process economics.

  14. Improvement on simultaneous determination of chromium species in aqueous solution by ion chromatography and chemiluminescence detection

    DEFF Research Database (Denmark)

    Gammelgaard, Bente; Liao, Y.P.; Jons, O.

    1997-01-01

    A sensitive method for the simultaneous determination of chromium(III) and chromium(VI) was chromatography and chemiluminescence detection. Two Dionex ion-exchange guard columns in series, CG5 and AG7, were used to separate chromium(III) from chromium(VI). Chromium(VI) was reduced by potassium...... sulphite, whereupon both species were detected by use of the luminol-hydrogen peroxide chemiluminescence system. Parameters affecting retention times and resolution of the separator columns, such as eluent pH, eluent composition, reductant pH and concentration, and flow rates were optimized. Furthermore...... was 1.4% for chromium(III) and 2.5% for chromium(VI), respectively. The accuracy of the chromium(III) determination was determined by analysis of the NIST standard reference material 1643c, Trace elements in water with the result 19.1 +/- 1.0 mu g Cr(III) l(-1) (certified value 19.0 +/- 0.6 mu g Cr...

  15. A simple ion chromatography method for inorganic anion analysis in edible seaweeds.

    Science.gov (United States)

    Gómez-Ordóñez, Eva; Alonso, Esther; Rupérez, Pilar

    2010-09-15

    A new, simple, fast and sensitive ion chromatography (IC) method, for the simultaneous analysis of fluoride, chloride, nitrite, bromide, nitrate, phosphate and sulphate in edible seaweeds was developed and reported for the first time. The validation of the analytical method was studied in terms of linearity, sensitivity, precision and accuracy. All standard calibration curves showed very good correlation between anion peak area and concentration (r>0.999). Limits of detection and quantitation ranged between 0.002-0.05 mg/L and 0.01-0.1mg/L, respectively and indicated the high sensitivity of the method. Relative standard deviation values of repeatability and inter-day precision for standard anions with the same sample were less than 2%. Anion recoveries ranged from 97 to 113% for chloride and from 87 to 105% for sulphate, respectively and showed the fairly good accuracy of the method. The method was applied to the analysis of inorganic anions in brown and red edible seaweeds. Brown seaweeds were characterized by higher chloride content up to 33.7-36.9%, while red seaweeds were characterized by higher sulphate content (45-57%). Sulphate content in seaweeds is related to the presence of sulphated polysaccharides of biological importance. The method developed was well applicable to mineral anion analysis in edible seaweeds and shows suitability and reliability of use in other food samples of nutritional importance. Copyright (c) 2010. Published by Elsevier B.V.

  16. Determination of common inorganic anions and cations by non-suppressed ion chromatography with column switching.

    Science.gov (United States)

    Amin, Muhammad; Lim, Lee Wah; Takeuchi, Toyohide

    2008-02-29

    An ion chromatography (IC) method has been proposed for the determination of seven common inorganic anions (F(-), H(2)PO(4)(-), NO(2)(-), Cl(-), Br(-), NO(3)(-), and SO(4)(2-)) and/or five common inorganic cations (Na(+), NH(4)(+), K(+), Mg(2+), and Ca(2+)) using a single pump, a single eluent and a single detector. The present system used cation-exchange and anion-exchange columns connected in series via a single 10-port switching valve. The 10-port valve was switched for the separation of either cations or anions in a single chromatographic run. When 1.0mM trimellitic acid (pH 2.94) was used as the eluent, the seven anions and the five cations could be separated on the anion-exchange column and the cation-exchange column, respectively. The elution order was found to be F(-)anions and Na(+)cations. Complete separation of the above anions or cations was demonstrated within 35min each. Detection limits calculated at S/N=3 were 0.05-0.58ppm (mg/l) for the anions and 0.05-0.38ppm for the cations, whereas repeatability values were below 2.26, 2.76, and 2.90% for peak height, peak area and retention time, respectively. The method was successfully applied to the determination of inorganic anions and cations in river water samples.

  17. Large-scale analysis of in Vivo phosphorylated membrane proteins by immobilized metal ion affinity chromatography and mass spectrometry

    DEFF Research Database (Denmark)

    Nühse, Thomas S; Stensballe, Allan; Jensen, Ole N

    2003-01-01

    Global analyses of protein phosphorylation require specific enrichment methods because of the typically low abundance of phosphoproteins. To date, immobilized metal ion affinity chromatography (IMAC) for phosphopeptides has shown great promise for large-scale studies, but has a reputation for poor...... specificity. We investigated the potential of IMAC in combination with capillary liquid chromatography coupled to tandem mass spectrometry for the identification of plasma membrane phosphoproteins of Arabidopsis. Without chemical modification of peptides, over 75% pure phosphopeptides were isolated from...... plasma membrane digests and detected and sequenced by mass spectrometry. We present a scheme for two-dimensional peptide separation using strong anion exchange chromatography prior to IMAC that both decreases the complexity of IMAC-purified phosphopeptides and yields a far greater coverage...

  18. Rapid, simple and stability-indicating determination of polyhexamethylene biguanide in liquid and gel-like dosage forms by liquid chromatography with diode-array detection

    National Research Council Canada - National Science Library

    Küsters, Markus; Beyer, Sören; Kutscher, Stephan; Schlesinger, Harald; Gerhartz, Michael

    2013-01-01

    A rapid and simple method for the determination of potyhexamethylene biguanide (polyhexanide, PHMB) in liquid and gel-like pharmaceutical formulations by means of high performance liquid chromatography coupled to diode-array detection...

  19. Rapid direct analysis to discriminate geographic origin of extra virgin olive oils by flash gas chromatography electronic nose and chemometrics.

    Science.gov (United States)

    Melucci, Dora; Bendini, Alessandra; Tesini, Federica; Barbieri, Sara; Zappi, Alessandro; Vichi, Stefania; Conte, Lanfranco; Gallina Toschi, Tullia

    2016-08-01

    At present, the geographical origin of extra virgin olive oils can be ensured by documented traceability, although chemical analysis may add information that is useful for possible confirmation. This preliminary study investigated the effectiveness of flash gas chromatography electronic nose and multivariate data analysis to perform rapid screening of commercial extra virgin olive oils characterized by a different geographical origin declared in the label. A comparison with solid phase micro extraction coupled to gas chromatography mass spectrometry was also performed. The new method is suitable to verify the geographic origin of extra virgin olive oils based on principal components analysis and discriminant analysis applied to the volatile profile of the headspace as a fingerprint. The selected variables were suitable in discriminating between "100% Italian" and "non-100% Italian" oils. Partial least squares discriminant analysis also allowed prediction of the degree of membership of unknown samples to the classes examined. Copyright © 2016. Published by Elsevier Ltd.

  20. Rapid and Accurate Identification of Animal Species in Natural Leather Goods by Liquid Chromatography/Mass Spectrometry.

    Science.gov (United States)

    Izuchi, Yukari; Takashima, Tsuneo; Hatano, Naoya

    2016-01-01

    The demand for leather goods has grown globally in recent years. Industry revenue is forecast to reach $91.2 billion by 2018. There is an ongoing labelling problem in the leather items market, in that it is currently impossible to identify the species that a given piece of leather is derived from. To address this issue, we developed a rapid and simple method for the specific identification of leather derived from cattle, horses, pigs, sheep, goats, and deer by analysing peptides produced by the trypsin-digestion of proteins contained in leather goods using liquid chromatography/mass spectrometry. We determined species-specific amino acid sequences by liquid chromatography/tandem mass spectrometry analysis using the Mascot software program and demonstrated that collagen α-1(I), collagen α-2(I), and collagen α-1(III) from the dermal layer of the skin are particularly useful in species identification.

  1. Determination of alkanolamines in cattails (Typha latifolia) utilizing electrospray ionization with selected reaction monitoring and ion-exchange chromatography.

    Science.gov (United States)

    Peru, Kerry M; Headley, John V; Doucette, William J

    2004-01-01

    Selected reaction monitoring (SRM) with electrospray ionization was used as a specific detection technique for the analysis of alkanolamines in plant tissue extracts. Ion-exchange chromatography was used as the method of separation. Quantification was based on monitoring the loss of either H2O or 2(H2O) from the protonated molecule [M+H]+. The method provided increased selectivity for all analytes and better detection limits for three of the six analytes investigated compared with an earlier method using selected ion monitoring with liquid chromatography. Instrumental detection limits ranged from 6-300 pg injected for monoethanolamine (MEA), monoisopropanolamine (MIPA), diethanolamine (DEA), methyldiethanolamine (MDEA), diisopropanolamine (DIPA), and triethanolamine (TEA). Method robustness and selectivity were demonstrated by the determination of DIPA and a known transformation product MIPA in over 35 plant extract samples derived from a laboratory study of plant uptake mechanisms. Copyright 2004 John Wiley and Sons, Ltd.

  2. A Comparison between Ion chromatography and Inductively Coupled Plasma for the Determination of Bromate in Certain Samples of Foodstuffs

    OpenAIRE

    Alanowd O. Mehder

    2015-01-01

    Ion chromatography (IC) and inductively coupled plasma (ICP-MS) both were applied for the determination of bromate in some food samples. Attempts were made to establish calibration curves, however in case of IC, an additional abnormal peak was found to overlap with the bromate peak. This renders IC to be unsuccessful in the determination of bromate compared to ICP-MS technique. ICP-MS was found to give accurate results; therefore, it was applied for the determination of bromate in different ...

  3. Rapid development of bromodomain probes using flow synthesis methods and frontal affinity chromatography

    OpenAIRE

    Ingham, Richard; Guetzoyan, Lucie; Nikbin, Nikzad; Ley, Steven V.

    2014-01-01

    This poster illustrates aspects of a project involving the development of new probes for bromodomain 9 protein. Flow chemistry technologies and remote monitoring techniques were used for the synthesis, and Frontal Affinity Chromatography assays were used for analysis of the products.

  4. Boosting Sensitivity in Liquid Chromatography-Fourier Transform Ion Cyclotron Resonance-Tandem Mass Spectrometry for Product Ion Analysis of Monoterpene Indole Alkaloids.

    Science.gov (United States)

    Nakabayashi, Ryo; Tsugawa, Hiroshi; Kitajima, Mariko; Takayama, Hiromitsu; Saito, Kazuki

    2015-01-01

    In metabolomics, the analysis of product ions in tandem mass spectrometry (MS/MS) is noteworthy to chemically assign structural information. However, the development of relevant analytical methods are less advanced. Here, we developed a method to boost sensitivity in liquid chromatography-Fourier transform ion cyclotron resonance-tandem mass spectrometry analysis (MS/MS boost analysis). To verify the MS/MS boost analysis, both quercetin and uniformly labeled (13)C quercetin were analyzed, revealing that the origin of the product ions is not the instrument, but the analyzed compounds resulting in sensitive product ions. Next, we applied this method to the analysis of monoterpene indole alkaloids (MIAs). The comparative analyses of MIAs having indole basic skeleton (ajmalicine, catharanthine, hirsuteine, and hirsutine) and oxindole skeleton (formosanine, isoformosanine, pteropodine, isopteropodine, rhynchophylline, isorhynchophylline, and mitraphylline) identified 86 and 73 common monoisotopic ions, respectively. The comparative analyses of the three pairs of stereoisomers showed more than 170 common monoisotopic ions in each pair. This method was also applied to the targeted analysis of MIAs in Catharanthus roseus and Uncaria rhynchophylla to profile indole and oxindole compounds using the product ions. This analysis is suitable for chemically assigning features of the metabolite groups, which contributes to targeted metabolome analysis.

  5. [Simultaneous determination of twenty-one organic acids in food by ion chromatography with eluent autogeneration].

    Science.gov (United States)

    Lin, Huaying; Lin, Fenghua; Sheng, Lina; Li, Yidan; Zhang, Qiong

    2007-01-01

    A novel ion chromatographic method was developed for the simultaneous determination of organic acids in food samples including quinic acid, acetic acid, pyruvic acid, ketosuccinic acid, mannitic acid, lactic acid, succinic acid, malic acid, tartaric acid, oxalic acid, fumaric acid, ascorbic acid, alpha-ketoglutaric acid, cinnamic acid, salicylic acid, citric acid, isocitric acid, ferulic acid, cis-aconitic acid, trans-aconitic acid, beta-coumaric acid. 5 - 34 mmol/L KOH produced by an EG40 eluent autogenerator could achieve a flat baseline and lower background conductance when performing gradient elution. The flow rate was 0.6 - 2.5 mL/min and the injection volume was 25 microL. The separation was performed on an IonPac AS11 column and detected by suppressed conductivity with self-regenerating suppressor mode. The samples were prepared through extraction, decoloration and filtration before analysis. Twenty-one organic acids showed good linear relationship between the mass concentration and the peak area in the measurement ranges. The correlation coefficients were above 0.999 and the detection limits were 0.011 - 0.188 mg/L, and the average recoveries were 91.5% - 101.8%. The method is simple and rapid with good accuracy and reproducibility, and has been applied to determine twenty-one organic acids in diversiform samples with satisfactory results.

  6. Mechanistic modeling of ion-exchange process chromatography of charge variants of monoclonal antibody products.

    Science.gov (United States)

    Kumar, Vijesh; Leweke, Samuel; von Lieres, Eric; Rathore, Anurag S

    2015-12-24

    Ion-exchange chromatography (IEX) is universally accepted as the optimal method for achieving process scale separation of charge variants of a monoclonal antibody (mAb) therapeutic. These variants are closely related to the product and a baseline separation is rarely achieved. The general practice is to fractionate the eluate from the IEX column, analyze the fractions and then pool the desired fractions to obtain the targeted composition of variants. This is, however, a very cumbersome and time consuming exercise. A mechanistic model that is capable of simulating the peak profile will be a much more elegant and effective way to make a decision on the pooling strategy. This paper proposes a mechanistic model, based on the general rate model, to predict elution peak profile for separation of the main product from its variants. The proposed approach uses inverse fit of process scale chromatogram for estimation of model parameters using the initial values that are obtained from theoretical correlations. The packed bed column has been modeled along with the chromatographic system consisting of the mixer, tubing and detectors as a series of dispersed plug flow and continuous stirred tank reactors. The model uses loading ranges starting at 25% to a maximum of 70% of the loading capacity and hence is applicable to process scale separations. Langmuir model has been extended to include the effects of salt concentration and temperature on the model parameters. The extended Langmuir model that has been proposed uses one less parameter than the SMA model and this results in a significant ease of estimating the model parameters from inverse fitting. The proposed model has been validated with experimental data and has been shown to successfully predict peak profile for a range of load capacities (15-28mg/mL), gradient lengths (10-30CV), bed heights (6-20cm), and for three different resins with good accuracy (as measured by estimation of residuals). The model has been also

  7. Simultaneous and sensitive analysis of aliphatic carboxylic acids by ion-chromatography using on-line complexation with copper(II) ion.

    Science.gov (United States)

    Kemmei, Tomoko; Kodama, Shuji; Yamamoto, Atsushi; Inoue, Yoshinori; Hayakawa, Kazuichi

    2015-01-02

    A new approach to ion chromatography is proposed to improve the UV detection of aliphatic carboxylic acids separated by anion-exchange chromatography. When copper(II) ion added to the mobile phase, it forms complexes with carboxylic acids that can be detected at 240 nm. The absorbance was found to increase with increasing copper(II) ion concentration. The retention times of α-hydroxy acids were also found to depend on the copper(II) ion concentration. Addition of acetonitrile to the mobile phase improved the separation of aliphatic carboxylic acids. The detection limits of the examined carboxylic acids (formate, glycolate, acetate, lactate, propionate, 3-hydroxypropionate, n-butyrate, isobutyrate, n-valerate, isovalerate, n-caproate) calculated at S/N=3 ranged from 0.06 to 3 μM. The detector signal was linear over three orders of magnitude of carboxylic acid concentration. The proposed method was successfully applied to analyze aliphatic carboxylic acids in rainwater and bread. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Rapid and Highly Sensitive Detection of Lead Ions in Drinking Water Based on a Strip Immunosensor

    Directory of Open Access Journals (Sweden)

    Chuanlai Xu

    2013-03-01

    Full Text Available In this study, we have first developed a rapid and sensitive strip immunosensor based on two heterogeneously-sized gold nanoparticles (Au NPs probes for the detection of trace lead ions in drinking water. The sensitivity was 4-fold higher than that of the conventional LFA under the optimized conditions. The visual limit of detection (LOD of the amplified method for qualitative detection lead ions was 2 ng/mL and the LOD for semi-quantitative detection could go down to 0.19 ng/mL using a scanning reader. The method suffered from no interference from other metal ions and could be used to detect trace lead ions in drinking water without sample enrichment. The recovery of the test samples ranged from 96% to 103%. As the detection method could be accomplished within 15 min, this method could be used as a potential tool for preliminary monitoring of lead contamination in drinking water.

  9. Rapid and highly sensitive detection of lead ions in drinking water based on a strip immunosensor.

    Science.gov (United States)

    Kuang, Hua; Xing, Changrui; Hao, Changlong; Liu, Liqiang; Wang, Libing; Xu, Chuanlai

    2013-03-28

    In this study, we have first developed a rapid and sensitive strip immunosensor based on two heterogeneously-sized gold nanoparticles (Au NPs) probes for the detection of trace lead ions in drinking water. The sensitivity was 4-fold higher than that of the conventional LFA under the optimized conditions. The visual limit of detection (LOD) of the amplified method for qualitative detection lead ions was 2 ng/mL and the LOD for semi-quantitative detection could go down to 0.19 ng/mL using a scanning reader. The method suffered from no interference from other metal ions and could be used to detect trace lead ions in drinking water without sample enrichment. The recovery of the test samples ranged from 96% to 103%. As the detection method could be accomplished within 15 min, this method could be used as a potential tool for preliminary monitoring of lead contamination in drinking water.

  10. Development of an anti-analyte ion remover used for ion chromatography: Part 1. Examination of a device for anion analysis.

    Science.gov (United States)

    Masunaga, Hiroto; Higo, Yuji; Ishii, Mizuo; Maruyama, Noboru; Yamazaki, Shigeo

    2012-01-01

    Herein, we report on the fabrication of a device for removing cations of an anti-analyte ion contained in a sample and an eluent under an electric field. The space in which the electrode is set on both sides of the device is separated into three cells using anion and cation exchange membranes. Each of the cells is packed with either an anion or cation exchange resin. Cation removal is performed by electrical regeneration, based on the electrokinetic phenomenon on both the surface of the ion exchange resins and the membranes. It was verified that the developed device has a very low dead volume, and sufficient capacity for the continuous removal of cations from the sample and the eluent. In addition, the detection sensitivity of ion chromatography (IC) was improved using this device as a suppressor, and a detection limit of anions on the sub-ppb order was achieved.

  11. Speciation analysis of arsenic compounds in seafood by ion chromatography-atomic fluorescence spectrometry

    Science.gov (United States)

    Han, Tingting; Ji, Hongwei; Li, Huixin; Cui, He; Song, Tian; Duan, Xiaojuan; Zhu, Qianlin; Cai, Feng; Zhang, Li

    2017-06-01

    Ion chromatography-ultra violet-hydride generation-Atomic Florescence Spectrometry was applied to detect 5 arsenic species in seafoods. The arsenic species studied include arsenobetaine (AsB), arsenite (As(III)), dimethylarsinic acid (DMA), monomethylarsonic acid (MMA), and arsenate (As(V)), which were extracted from samples using 2% formic acid. Gradient elution using 33 mmol L-1 CH3COONH4 and 15 mmol L-1 Na2CO3 with 10 mL CH3CH2OH at pH 8.4 allowed the chromatographic separation of all the species on a Hamilton PRP-X100 anion-exchange column in less than 8 min. In this study, an ultrasound extraction method was used to extract arsenic species from seafood. The extraction efficiency was good and the recoveries from spiked samples were in the range of 72.6%-109%; the precision between sample replicates was higher than 3.6% for all determinations. The detection limits were 3.543 μg L-1 for AsB, 0.426 μg L-1 for As(III), 0.216 μg L-1 for DMA, 0.211 μg L-1 for MMA, and 0.709 μg L-1 for As(V), and the linear coefficients were greater than 0.999. We also developed an application of this method for the determination of arsenic species in bonito, Euphausia superba, and Enteromorpha with satisfactory results. Therefore, it was confirmed that this method was appropriate for the detection of arsenic species in seafood.

  12. Simultaneous determination of three chloroacetic acids, three herbicides, and 12 anions in water by ion chromatography.

    Science.gov (United States)

    Luo, Ximing; Chen, Liang; Zhao, Yanqing

    2015-09-01

    An ion chromatography method was developed for the simultaneous detection of three soluble herbicides (glyphosate, bentazone and picloram), three chlorine disinfection byproducts (monochloroacetic acid, dichloroacetic acid and trichloroacetic acid) and 12 anions in water (Cl(-), Br(-), SO4(2-), CO3(2-), ClO3(-), ClO4(-), BrO3(-), PO4(3-), NO2(-), NO3(-), CH3COO(-) and COO(-)). High linearity (r(2) > 0.996) was observed for all target analytes for each respective concentration range. The limit of detection and limit of quantitation were between 0.21-0.85 and 0.06-25.46 μg/L, respectively. However, the interference effect of Cl(-), NO3(-) , SO4 (2-) and CO3(2-) on some target analytes must be considered during the analysis. Sample pre-treatment by a hydrogen column (H-column) required to reduce the negative effect of CO3(2-). Additionally, sample pre-treatment by a sliver-hydrogen column (Ag-H-column) is required when Cl(-) > 100 mg/L and SO4(2-) 100 mg/L and SO4(2-) > 50 mg/L. When Cl(-) > 100 mg/L, SO4(2-) > 50 mg/L and CO3(2-) > 20 mg/L, the sample pre-treatment by either an Ag-H-Ba-column or an Ag-H-column and Ba-column is required to minimize interference. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Use of Ionic liquids as additives in ion exchange chromatography for the analysis of cations.

    Science.gov (United States)

    Di, Huawei; Zhu, Xiashi

    2017-11-01

    The behavior of acids (citric acid, nitric acid, oxalic acid, tartaric acid) as a mobile phase and imidazolium ionic liquids (the bromides, tetrafluoroborates and hexafluorophosphates of 1-ethyl, 1-butyl, and 1-hexyl-3-methylimidazolium) as additives in ion exchange chromatography for cations (Na+ , K+ , Mg2+ , Ca2+ ) separation were studied. The results showed that nitric acid and 1-hexyl-3-methyl-imidazolium hexafluorophosphate offered the most interesting features in the separation of cations, such as lower retention time and better resolution. The selected optimal conditions were achieved by adding 0.10 mM 1-hexyl-3-methyl-imidazolium hexafluorophosphate in 4.0 mM HNO3 mobile phase for the separation of four cations with the flow rate of 0.9 mL/min at room temperature (25°C). The linear regression equations of Na+ , K+ , Mg2+ , Ca2+ were S = 4.4763c + 0.0209, S = 3.8903c - 0.0087, S = 6.3974c - 0.0173, and S = 7.601c - 0.0339 and the limits of detection of Na+ , K+ , Mg2+ , Ca2+ were 0.296, 4.98, 0.0970, and 1.22 μg/L, respectively. In this work, four cations in samples were successfully detected. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. LC-IMS-MS Feature Finder: detecting multidimensional liquid chromatography, ion mobility and mass spectrometry features in complex datasets.

    Science.gov (United States)

    Crowell, Kevin L; Slysz, Gordon W; Baker, Erin S; LaMarche, Brian L; Monroe, Matthew E; Ibrahim, Yehia M; Payne, Samuel H; Anderson, Gordon A; Smith, Richard D

    2013-11-01

    The addition of ion mobility spectrometry to liquid chromatography-mass spectrometry experiments requires new, or updated, software tools to facilitate data processing. We introduce a command line software application LC-IMS-MS Feature Finder that searches for molecular ion signatures in multidimensional liquid chromatography-ion mobility spectrometry-mass spectrometry (LC-IMS-MS) data by clustering deisotoped peaks with similar monoisotopic mass, charge state, LC elution time and ion mobility drift time values. The software application includes an algorithm for detecting and quantifying co-eluting chemical species, including species that exist in multiple conformations that may have been separated in the IMS dimension. LC-IMS-MS Feature Finder is available as a command-line tool for download at http://omics.pnl.gov/software/LC-IMS-MS_Feature_Finder.php. The Microsoft.NET Framework 4.0 is required to run the software. All other dependencies are included with the software package. Usage of this software is limited to non-profit research to use (see README). rds@pnnl.gov. Supplementary data are available at Bioinformatics online.

  15. A Liquid Chromatography Detector for Transition and Rare-Earth Metal Ions Based on a Cupric Ion-Selective Electrode

    Science.gov (United States)

    1981-05-01

    selective Electrode A Transition Metal CuI) Rare Earth Potentiometry Lanthanide Flow-through Electrode 20. ABSTRACT (Continue on reverse side if necessary...Flow Potentiometry with Ion-selective Electrodes ..... . 19 i. Introduction - Ideal Ion-selective Electrodes . ... 19 2. Interferences...detector is less than I pL, creating much less peak broadening than the earlier polarographic detectors (9,10). C. Flow Potentiometry with Ion-Selective

  16. Identification of terpenes and essential oils by means of static headspace gas chromatography-ion mobility spectrometry.

    Science.gov (United States)

    Rodríguez-Maecker, Roman; Vyhmeister, Eduardo; Meisen, Stefan; Rosales Martinez, Antonio; Kuklya, Andriy; Telgheder, Ursula

    2017-11-01

    Static headspace gas chromatography-ion mobility spectrometry (SHS GC-IMS) is a relatively new analytical technique that has considerable potential for analysis of volatile organic compounds (VOCs). In this study, SHS GC-IMS was used for the identification of the major terpene components of various essential oils (EOs). Based on the data obtained from 25 terpene standards and 50 EOs, a database for fingerprint identification of characteristic terpenes and EOs was generated utilizing SHS GC-IMS for authenticity testing of fragrances in foods, cosmetics, and personal care products. This database contains specific normalized IMS drift times and GC retention indices for 50 terpene components of EOs. Initially, the SHS GC-IMS parameters, e.g., drift gas and carrier gas flow rates, drift tube, and column temperatures, were evaluated to determine suitable operating conditions for terpene separation and identification. Gas chromatography-mass spectrometry (GC-MS) was used as a reference method for the identification of terpenes in EOs. The fingerprint pattern based on the normalized IMS drift times and retention indices of 50 terpenes is presented for 50 EOs. The applicability of the method was proven on examples of ten commercially available food, cosmetic, and personal care product samples. The results confirm the suitability of SHS GC-IMS as a powerful analytical technique for direct identification of terpene components in solid and liquid samples without any pretreatment. Graphical abstract Fingerprint pattern identification of terpenes and essential oils using static headspace gas chromatography-ion mobility spectrometry.

  17. Liquid chromatography with mass spectrometry method based two-step precursor ion scanning for the structural elucidation of flavonoids.

    Science.gov (United States)

    Li, Yong; Pang, Tao; Shi, Junli; Lu, Xiuping; Deng, Jianhua; Lin, Qian

    2014-11-01

    Plant flavonoids are very important secondary metabolites for insect and virus control of their host plant and are potent nutrients for humans. To be able to understand the bioavailability and functions of plant flavonoids, it is necessary to reveal their exact chemical structures. Liquid chromatography with tandem mass spectrometry is a powerful approach for structural elucidation of metabolites. In this report, a two-step precursor ion scanning based liquid chromatography with tandem mass spectrometry method was developed for the structural elucidation of plant flavonoids. The established method consists of the two-step precursor ions scanning for possible flavonoids extraction, MS(2) fragment spectra acquisition and comparison with an online database, liquid chromatography retention rules correction, and commercial standards verification. The developed method was used for the structure elucidation of flavonoids in flowers and leaves of tobacco (Nicotiana tabacum), and 17 flavonoids were identified in the tobacco variety Yunyan 97. Nine of the 17 identified flavonoids were considered to be found in tobacco flowers or/and leaves for the first time based on the available references. This method was proved to be very effective and can be used for the identification of flavonoids in other plants. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Investigation of Symphytum cordatum alkaloids by liquid-liquid partitioning, thin-layer chromatography and liquid chromatography-ion-trap mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Mroczek, Tomasz [Department of Pharmacognosy with Medicinal Plants Laboratory, Medical University, 1 Chodzki St., 20-093 Lublin (Poland)]. E-mail: tmroczek@pharmacognosy.org; Ndjoko-Ioset, Karine [Laboratoire de Pharmacognosie et Phytochimie, Ecole de Pharmacie Geneve-Lausanne, Universite de Geneve, Quai Ernest-Ansermet 30, CH-1211 Geneva 4 (Switzerland); Glowniak, Kazimierz [Department of Pharmacognosy with Medicinal Plants Laboratory, Medical University, 1 Chodzki St., 20-093 Lublin (Poland); Mietkiewicz-Capala, Agnieszka [Department of Pharmacognosy with Medicinal Plants Laboratory, Medical University, 1 Chodzki St., 20-093 Lublin (Poland); Hostettmann, Kurt [Laboratoire de Pharmacognosie et Phytochimie, Ecole de Pharmacie Geneve-Lausanne, Universite de Geneve, Quai Ernest-Ansermet 30, CH-1211 Geneva 4 (Switzerland)

    2006-05-04

    From the alkalised crude extract of Symphytum cordatum (L.) W.K. roots, pyrrolizidine alkaloids (PAs) were extracted as free tertiary bases and polar N-oxides in a merely one-step liquid-liquid partitioning (LLP) in separation funnel and subsequently pre-fractionated by preparative multiple-development (MD) thin-layer chromatography (TLC) on silica gel plates. In this way three alkaloid fractions of different polarities and retention on silica gel plates were obtained as: the most polar N-oxides of the highest retention, the tertiary bases of medium retention, and diesterified N-oxides of the lowest retention. The former fraction was reduced into free bases by sodium hydrosulfite and purified by LLP on Extrelut-NT3 cartridge. It was further analysed together with the two other fractions by high-performance liquid chromatography (HPLC)-ion-trap mass spectrometry with atmospheric pressure chemical ionization (APCI) interface on XTerra C{sub 18} column using a gradient elution. Based on MS {sup n} spectra, 18 various alkaloids have been tentatively determined for the first time in this plant as the following types of structure: echimidine-N-oxide (three diasteroisomers), 7-sarracinyl-9-viridiflorylretronecine (two diasteroisomers), echimidine (two diasteroisomers), lycopsamine (two diasteroisomers), dihydroechinatine-N-oxide, dihydroheliospathuline-N-oxide, lycopsamine-N-oxide (three diasteroisomers), 7-acetyllycopsamine-N-oxide, symphytine-N-oxide (two diasteroisomers) and 2'',3''-epoxyechiumine-N-oxide.

  19. The quantitation of 2-oxo-3-hydroxy lysergic acid diethylamide (O-H-LSD) in human urine specimens, a metabolite of LSD: comparative analysis using liquid chromatography-selected ion monitoring mass spectrometry and liquid chromatography-ion trap mass spectrometry.

    Science.gov (United States)

    Poch, G K; Klette, K L; Anderson, C

    2000-04-01

    This paper compares the potential forensic application of two sensitive and rapid procedures (liquid chromatography-mass spectrometry and liquid chromatography-ion trap mass spectrometry) for the detection and quantitation of 2-oxo-3-hydroxy lysergic acid diethylamide (O-H-LSD) a major LSD metabolite. O-H-LSD calibration curves for both procedures were linear over the concentration range 0-8,000 pg/mL with correlation coefficients (r2) greater than 0.99. The observed limit of detection (LOD) and limit of quantitation (LOQ) for O-H-LSD in both procedures was 400 pg/mL. Sixty-eight human urine specimens that had previously been found to contain LSD by gas chromatography-mass spectrometry were reanalyzed by both procedures for LSD and O-H-LSD. These specimens contained a mean concentration of O-H-LSD approximately 16 times higher than the LSD concentration. Because both LC methods produce similar results, either procedure can be readily adapted to O-H-LSD analysis for use in high-volume drug-testing laboratories. In addition, the possibility of significantly increasing the LSD detection time window by targeting this major LSD metabolite for analysis may influence other drug-free workplace programs to test for LSD.

  20. Determination of total sulfite in wine by ion chromatography after in-sample oxidation.

    Science.gov (United States)

    Koch, Matthias; Köppen, Robert; Siegel, David; Witt, Angelika; Nehls, Irene

    2010-09-08

    Sulfur dioxide (SO2) or sulfites are the most common preservatives used in winemaking. The level of total SO2 is subject to regulation. Currently, the regulatory determination of total SO2 (including sulfites) is done by the optimized Monier-Williams (OMW) method, which includes time-consuming distillation and titration steps. This paper describes the development and application of an alternative, rapid, straightforward, and reliable method for the determination of total sulfite in wine. In this method, a simple oxidation step using alkaline hydrogen peroxide (H2O2) solution is followed by ion chromatographic (IC) analysis of sulfate coupled with conductometric detection. Thirteen wines were analyzed in order to compare the in-sample oxidation method with the OMW-procedure. A t-test revealed satisfying compliance regarding sample preparation, i.e., alkaline H2O2 treatment and acidic distillation (OMW method). Comparable results were also obtained between IC analysis and acid/base titration. Our results indicate that the novel method (limit of quantification: 4 mg SO2 L(-1)) is well suited for the cost-efficient monitoring of regulatory limits.

  1. Applications of Frontal Affinity Chromatography to the Study of Interactions between Metal Ions and a Complex Biomaterial.

    Science.gov (United States)

    Lin, S; Drake, L R; Rayson, G D

    1996-12-01

    The use of frontal affinity chromatography for the study of metal-biomaterial interactions is described. Both normal frontal affinity chromatography and a modification of this methodology were used to generate metal binding isotherms to a biomaterial. This modification enabled the acquisition of binding isotherms with extended concentration ranges at the expense of time-dependent binding information. Comparison between normal and modified mode was made by using a well-defined commercial resin. Similar performance of these two modes was obtained. The biomaterial investigated was composed of cell fragments from the plant Datura innoxia which were immobilized within a polysilicate matrix. The application of a regularized least-squares method indicated the existence of two classes of sites on this biosorbent involved in the binding of Ag(+). A total metal-ion binding affinity order at solution pH 3-5 was determined to be Cu(2+) > Cd(2+) ≈ Ag(+) > Ca(2+).

  2. Microwave-assisted chemical insertion: a rapid technique for screening cathodes for Mg-ion batteries

    Energy Technology Data Exchange (ETDEWEB)

    Kaveevivitchai, Watchareeya; Huq, Ashfia; Manthiram, Arumugam

    2016-12-19

    We report an ultrafast microwave-assisted solvothermal method for chemical insertion of Mg2+ ions into host materials using magnesium acetate [Mg(CH3COO)2] as a metal-ion source and diethylene glycol (DEG) as a reducing agent. For instance, up to 3 Mg ions per formula unit of a microporous host framework Mo2.5+yVO9+z could be inserted in as little as 30 min at 170–195 °C in air. This process is superior to the traditional method which involves the use of organometallic reagents, such as di-n-butylmagnesium [(C4H9)2Mg] and magnesium bis(2,6-di-tert-butylphenoxide) [Mg-(O-2,6-But2C6H3)2], and requires an inert atmosphere with extremely long reaction times. Considering the lack of robust electrolytes for Mg-ion batteries, this facile approach can be readily used as a rapid screening technique to identify potential Mg-ion electrode hosts without the necessity of fabricating electrodes and assembling electrochemical cells. Due to the mild reaction conditions, the overall structure and morphology of the Mg-ion inserted products are maintained and the compounds can be used successfully as a cathode in Mg-ion batteries. The combined synchrotron X-ray and neutron diffraction Rietveld analysis reveals the structure of the Mg-inserted compounds and gives an insight into the interactions between the Mg ions and the open-tunnel host framework.

  3. Rapid determination of trace level copper in tea infusion samples by solid contact ion selective electrode

    Directory of Open Access Journals (Sweden)

    Aysenur Birinci

    2016-07-01

    Full Text Available A new solid contact copper selective electrode with a poly (vinyl chloride (PVC membrane consisting of o-xylylenebis(N,N-diisobutyldithiocarbamate as ionophore has been prepared. The main novelties of constructed ion selective electrode concept are the enhanced robustness, cheapness, and fastness due to the use of solid contacts. The electrode exhibits a rapid (< 10 seconds and near-Nernstian response to Cu2+ activity from 10−1 to 10−6 mol/L at the pH range of 4.0–6.0. No serious interference from common ions was found. The electrode characterizes by high potential stability, reproducibility, and full repeatability. The electrode was used as an indicator electrode in potentiometric titration of Cu(II ions with EDTA and for the direct assay of tea infusion samples by means of the calibration graph technique. The results compared favorably with those obtained by the atomic absorption spectroscopy (AAS.

  4. Ion Chromatography Based Urine Amino Acid Profiling Applied for Diagnosis of Gastric Cancer

    Directory of Open Access Journals (Sweden)

    Jing Fan

    2012-01-01

    Full Text Available Aim. Amino acid metabolism in cancer patients differs from that in healthy people. In the study, we performed urine-free amino acid profile of gastric cancer at different stages and health subjects to explore potential biomarkers for diagnosing or screening gastric cancer. Methods. Forty three urine samples were collected from inpatients and healthy adults who were divided into 4 groups. Healthy adults were in group A (n=15, early gastric cancer inpatients in group B (n=7, and advanced gastric cancer inpatients in group C (n=16; in addition, two healthy adults and three advanced gastric cancer inpatients were in group D (n=5 to test models. We performed urine amino acids profile of each group by applying ion chromatography (IC technique and analyzed urine amino acids according to chromatogram of amino acids standard solution. The data we obtained were processed with statistical analysis. A diagnostic model was constructed to discriminate gastric cancer from healthy individuals and another diagnostic model for clinical staging by principal component analysis. Differentiation performance was validated by the area under the curve (AUC of receiver-operating characteristic (ROC curves. Results. The urine-free amino acid profile of gastric cancer patients changed to a certain degree compared with that of healthy adults. Compared with healthy adult group, the levels of valine, isoleucine, and leucine increased (P<0.05, but the levels of histidine and methionine decreased (P<0.05, and aspartate decreased significantly (P<0.01. The urine amino acid profile was also different between early and advanced gastric cancer groups. Compared with early gastric cancer, the levels of isoleucine and valine decreased in advanced gastric cancer (P<0.05. A diagnosis model constructed for gastric cancer with AUC value of 0.936 tested by group D showed that 4 samples could coincide with it. Another diagnosis model for clinical staging with an AUC value of 0.902 tested by

  5. Coupling frontal elution paper chromatography with desorption corona beam ionization mass spectrometry for rapid analysis of chlorphenamine in herbal medicines and dietary supplements.

    Science.gov (United States)

    Huang, Yun-Qing; You, Jing-Qing; Zhang, Junsheng; Sun, Wenjian; Ding, Li; Feng, Yu-Qi

    2011-10-14

    We developed a convenient method by coupling frontal elution paper chromatography with desorption corona beam ionization mass spectrometry (DCBI-MS) for rapid determination of chlorphenamine added in herbal medicines or dietary supplements. In this method, the ethanol extract of the herbal products was spotted directly onto an isosceles triangular filter paper sheet, and then the paper sheet was developed under strong elution condition with the sample zone migrating at the solvent front. The analyte was finally condensed at the V-shaped tip which could then be placed under the visible plasma beam of DCBI for ionization. The overall procedure took less than 5 min. The frontal elution paper chromatography on a triangular plate used in this work improved the signal intensity of chlorphenamine by 30-fold due to the analyte condensing at the tip and the reduction of the background suppression. Furthermore, the paper sheet also functioned as a filter in the analysis of solid or powder samples, which can increase the analytical throughput by omitting the step of centrifugation. The proposed method in current study was successfully applied in the determination of chlorphenamine in herbal medicines. Chlorphenamine was detected in four of the twelve types of herbal medicines examined in this study. The limit of detection was 200 ng/mL (2.0 ng absolute) in full-scan positive-ion mode and the linear range was from 5.0 μg/mL to 50 μg/mL with satisfactory linear coefficient (R(2) (the square of the correlation coefficient)=0.895). Good reproducibility was achieved with relative standard deviations (RSDs) less than 15.0% and the recoveries of chlorphenamine ranged from 84.3 to 90.6%. Copyright © 2011 Elsevier B.V. All rights reserved.

  6. Utilizing ion-pairing hydrophilic interaction chromatography solid phase extraction for efficient glycopeptide enrichment in glycoproteomics

    DEFF Research Database (Denmark)

    Mysling, Simon; Palmisano, Giuseppe; Højrup, Peter

    2010-01-01

    Glycopeptide enrichment is a prerequisite to enable structural characterization of protein glycosylation in glycoproteomics. Here we present an improved method for glycopeptide enrichment based on zwitter-ionic hydrophilic interaction chromatography solid phase extraction (ZIC-HILIC SPE...

  7. Rapid purification of diastereoisomers from Piper kadsura using supercritical fluid chromatography with chiral stationary phases.

    Science.gov (United States)

    Xin, Huaxia; Dai, Zhuoshun; Cai, Jianfeng; Ke, Yanxiong; Shi, Hui; Fu, Qing; Jin, Yu; Liang, Xinmiao

    2017-08-04

    Supercritical fluid chromatography (SFC) with chiral stationary phases (CSPs) is an advanced solution for the separation of achiral compounds in Piper kadsura. Analogues and stereoisomers are abundant in natural products, but there are obstacles in separation using conventional method. In this paper, four lignan diastereoisomers, (-)-Galbelgin, (-)-Ganschisandrin, Galgravin and (-)-Veraguensin, from Piper kadsura were separated and purified by chiral SFC. Purification strategy was designed, considering of the compound enrichment, sample purity and purification throughput. Two-step achiral purification method on chiral preparative columns with stacked automated injections was developed. Unconventional mobile phase modifier dichloromethane (DCM) was applied to improve the sample solubility. Four diastereoisomers was prepared at the respective weight of 103.1mg, 10.0mg, 152.3mg and 178.6mg from 710mg extract with the purity of greater than 98%. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Rapid in vitro test to predict ocular tissue permeability based on biopartitioning micellar chromatography.

    Science.gov (United States)

    Martín-Biosca, Y; Molero-Monfort, M; Sagrado, S; Villanueva-Camañas, R M; Medina-Hernández, M J

    2003-10-01

    The drug permeability prediction across the ocular tissues is important in the development of new drugs and drug delivery strategies. Physicochemical characteristics of drugs, mainly acid-base character, hydrophobicity and the molecular size determine both their transport across the eye tissue barriers and their retention in biopartitioning micellar chromatography (BMC). An in vitro model able to describe and predict the whole cornea drug permeability is proposed. The model uses the retention of drugs in BMC and molecular weight (MW) as predictive variables. The relationships between drug retention data in BMC and their bibliographic permeability values in stroma, epithelium-plus-stroma and endothelium-plus-stroma are also studied. The results show that BMC can be a useful tool to select drug candidates according to their whole cornea permeability at the early stage of the drug discovery process.

  9. An improved thin-layer chromatography/mass spectrometry coupling using a surface sampling probe electrospray ion trap system

    Energy Technology Data Exchange (ETDEWEB)

    Ford, Michael J [ORNL; Van Berkel, Gary J [ORNL

    2004-01-01

    A combined surface sampling probe/electrospray emitter coupled with an ion trap mass spectrometer was used for the direct read out of unmodified reversed-phase C18 thin-layer chromatography (TLC) plates. The operation of the surface sampling electrospray ionization interface in positive and negative ionization modes was demonstrated through the direct analysis of TLC plates on which a commercial test mix comprised of four dye compounds viz., rhodamine B, fluorescein, naphthol blue black, and fast green FCF, and an extract of the caffeine-containing plant Ilex vomitoria, were spotted and developed. Acquisition of full-scan mass spectra and automated collection of MS/MS product ion spectra while scanning a development lane along the surface of a TLC plate demonstrated the advantages of using an ion trap in this combination. Details of the sampling system, benefits of analyzing a developed lane in both positive ion and negative ion modes, levels of detection while surface scanning, surface scan speed effects, and the utility of three-dimensional data display, are also discussed.

  10. IonLab. A remote-controlled experiment for academic and vocational education and training on extraction chromatography and ion exchange

    Energy Technology Data Exchange (ETDEWEB)

    Schulz, Wolfgang; Fournier, Claudia; Vahlbruch, Jan-Willem; Walther, Clemens [Leibniz Univ., Hannover (Germany). Inst. for Radioecology and Radiation Protection (IRS)

    2016-07-01

    As a major contribution to modern web-based education and training in nuclear chemistry we have built and operated a remote-controlled experiment - IonLab - as part of the integrated EUFP7 project CINCHII. The setup is suitable for teaching basics on extraction chromatography and ion exchange using radionuclides. We describe separation of the beta emitting nuclides Sr-90 and Y-90 followed by radiometric detection, but the experiment is easily adapted to other separation schemes. This approach is aimed at institutions in academic or vocational education who need to convey the skills of handling radioactive (or otherwise dangerous, e.g. biotoxic) substances without appropriately licensed laboratory space for teaching. This camera-monitored remote controlled lab experiment has proved to be much closer to a real hands-on training and superior to a mere computer simulation.

  11. Total iodine quantification in fluids and tissues from iodine- or iodide-supplemented rats by ion chromatography following microwave-assisted digestion.

    Science.gov (United States)

    Delgado, Guadalupe; Muñoz-Torres, Carolina; Orozco-Esquivel, Teresa; Anguiano, Brenda; Aceves, Carmen

    2015-03-01

    Iodine is a crucial component of thyroid hormones, and several reports have shown that iodine per se is implicated in the physiopathology of other organs. Innovative ion chromatography detection following a four-step temperature ramp microwave digestion in 25-50 mM nitric acid was developed to measure total iodine in biological fluids and tissue samples from female Sprague-Dawley rats supplemented with 0.05% molecular iodine (I2) or 0.05% potassium iodide (I(-)) in drinking water. The reported method allows the measurement of total iodine with a limit of quantification of 13.7 μg L(-1), recoveries of 96.3-100.3%, and intra- and inter-assay variations, of 3.5% and 7.4% respectively. Analysis of biological fluids showed that after 48 hours, iodine-supplemented animals exhibited significantly higher levels of total iodine in both serum and urine compared with those supplemented with iodide. The half-life of iodine in serum and urine measured over the first 48 h showed similar patterns for both the I2 (7.89 and 7.76 hours) and I(-) (8.27 and 8.90 hours) supplements. Differential uptake patterns were observed in tissues after 6 days of supplements, with I(-) preferentially retained by thyroid, lactating mammary gland, and milk, and a slightly but significantly higher capture of I2 in pituitary, ovary, and virgin mammary gland. We developed a rapid, selective, and accurate digestion method to process fluid and tissue samples that permits reproducible measurements of total iodine by ion chromatography; iodine or iodide supplement show a similar serum and urine half-life, but organ-specific uptake depends on the chemical form of the iodine supplement.

  12. High performance liquid chromatography method for rapid and accurate determination of homocysteine in plasma and serum

    DEFF Research Database (Denmark)

    Vester, Birte; Rasmussen, K

    1991-01-01

    Determination of homocysteine in plasma or serum for evaluation of cobalamin and folate deficiency is becoming an important diagnostic procedure. Accurate, rapid and low cost methods for measuring homocysteine are therefore required. We have improved an HPLC method and made it suitable for clinical...

  13. A simple and rapid ultra-high-performance liquid chromatography-tandem mass spectrometry method to determine plasma biotin in hemodialysis patients.

    Science.gov (United States)

    Yagi, Shigeaki; Nishizawa, Manabu; Ando, Itiro; Oguma, Shiro; Sato, Emiko; Imai, Yutaka; Fujiwara, Masako

    2016-08-01

    A simple, rapid, and selective method for determination of plasma biotin was developed using ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). After single-step protein precipitation with methanol, biotin and stable isotope-labeled biotin as an internal standard (IS) were chromatographed on a pentafluorophenyl stationary-phase column (2.1 × 100 mm, 2.7 μm) under isocratic conditions using 10 mm ammonium formate-acetonitrile (93:7, v/v) at a flow rate of 0.6 mL/min. The total chromatographic runtime was 5 min for each injection. Detection was performed in a positive electrospray ionization mode by monitoring selected ion transitions at m/z 245.1/227.0 and 249.1/231.0 for biotin and the IS, respectively. The calibration curve was linear in the range of 0.05-2 ng/mL using 300 μL of plasma. The intra- and inter-day precisions were all biotin concentrations in hemodialysis patients. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  14. Rapid Separation of Elemental Species by Fast Multicapillary Gas Chromatography with Multichannel Optical Spectrometry Detection following Headspace Solid Phase Microextraction

    Directory of Open Access Journals (Sweden)

    Jacek Giersz

    2015-05-01

    Full Text Available A method for conducting fast and efficient gas chromatography based on short multicapillaries in straight alignment combined with atomic emission detection was developed for field analysis. The strategy enables for speciation analysis of organometallic compounds. The analytes are simultaneously ethylated and preconcentrated on a solid phase microextraction (SPME fiber placed in the headspace over the sample for 25 min. The ethylated species are then completely separated and selectively quantified within 25 s under isothermal conditions. A new miniaturized speciation analyzer has been constructed and evaluated. The system consists of a GC injection port and a lab-made miniaturized GC unit directly coupled with miniaturized plasma excitation source. The emitted light is transferred via optical fiber and registered with a miniaturized charged coupled device (CCD based spectrometer. Working parameters for multicapillary column gas chromatography with atomic emission detector, including carrier gas flow rate, desorption temperature, and GC column temperature, were optimized to achieve good separation of analytes. Basic investigations of the fundamental properties of 5 cm-long multicapillary column, to evaluate its potential and limitations as a rapid separation unit, are presented. The adaptation of the technique for use with a SPME system and with a multichannel element-selective plasma-emission detector is highlighted.

  15. The simultaneous determination of active ingredients in cough-cold mixtures by isocratic reversed-phase ion-pair high-performance liquid chromatography.

    Science.gov (United States)

    Lau, O W; Chan, K; Lau, Y K; Wong, W C

    1989-01-01

    A simple, rapid and accurate method for the simultaneous determination of active ingredients in cough-cold mixtures using isocratic reversed-phase ion-pair high-performance liquid chromatography has been developed. It involves the use of an octadecylsilane column as the stationary phase with methanol, water, tetrahydrofuran, phosphoric acid mixtures as mobile phase including sodium dioctylsulphosuccinate as the ion-pair agent. The pH of the mobile phase was adjusted to 4.6 by means of phosphoric acid and ammonium hydroxide solutions. The proposed method involves the simple dilution of the samples with the mobile phase and the addition of metoclopramide hydrochloride as the internal standard. The active ingredients under investigation were chlorpheniramine, codeine, diphenhydramine, ephedrine, ethylmorphine, phenylephrine, phenylpropanolamine and pholcodine, which exist as various combinations in cough-cold mixtures. The optimum composition of the mobile phase and the optimum flow rate were determined and are reported. The method was applied to the determination of active ingredients in seven commercially available cough-cold mixtures.

  16. Monitoring of selected skin- and breath-borne volatile organic compounds emitted from the human body using gas chromatography ion mobility spectrometry (GC-IMS).

    Science.gov (United States)

    Mochalski, Paweł; Wiesenhofer, Helmut; Allers, Maria; Zimmermann, Stefan; Güntner, Andreas T; Pineau, Nicolay J; Lederer, Wolfgang; Agapiou, Agapios; Mayhew, Christopher A; Ruzsanyi, Veronika

    2018-02-15

    Human smuggling and associated cross-border crimes have evolved as a major challenge for the European Union in recent years. Of particular concern is the increasing trend of smuggling migrants hidden inside shipping containers or trucks. Therefore, there is a growing demand for portable security devices for the non-intrusive and rapid monitoring of containers to detect people hiding inside. In this context, chemical analysis of volatiles organic compounds (VOCs) emitted from the human body is proposed as a locating tool. In the present study, an in-house made ion mobility spectrometer coupled with gas chromatography (GC-IMS) was used to monitor the volatile moieties released from the human body under conditions that mimic entrapment. A total of 17 omnipresent volatile compounds were identified and quantified from 35 ion mobility peaks corresponding to human presence. These are 7 aldehydes (acrolein, 2-methylpropanal, 3-methylbutanal, 2-ethacrolein, n-hexanal, n-heptanal, benzaldehyde), 3 ketones (acetone, 2-pentanone, 4-methyl-2-pentanone), 5 esters (ethyl formate, ethyl propionate, vinyl butyrate, butyl acetate, ethyl isovalerate), one alcohol (2-methyl-1-propanol) and one organic acid (acetic acid). The limits of detection (0.05-7.2 ppb) and relative standard deviations (0.6-11%) should be sufficient for detecting these markers of human presence in field conditions. This study shows that GC-IMS can be used as a portable field detector of hidden or entrapped people. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Rapid determination of Papaver somniferum alkaloids in process streams using monolithic column high-performance liquid chromatography with chemiluminescence detection

    Energy Technology Data Exchange (ETDEWEB)

    Costin, Jason W. [School of Life and Environmental Sciences, Deakin University, Geelong, Victoria 3217 (Australia); Lewis, Simon W. [Department of Applied Chemistry, Curtin University of Technology, Perth, WA 6845 (Australia); Purcell, Stuart D. [GlaxoSmithKline, Port Fairy, Victoria 3284 (Australia); Waddell, Lucy R. [GlaxoSmithKline, Port Fairy, Victoria 3284 (Australia); Francis, Paul S. [School of Life and Environmental Sciences, Deakin University, Geelong, Victoria 3217 (Australia); Barnett, Neil W. [School of Life and Environmental Sciences, Deakin University, Geelong, Victoria 3217 (Australia)]. E-mail: barnie@deakin.edu.au

    2007-07-30

    We have combined high-performance liquid chromatography (HPLC) separations using a monolithic column with acidic potassium permanganate and tris(2,2'-bipyridyl)ruthenium(II) chemiluminescence detection in a rapid and highly sensitive method to monitor the process of extracting opiate alkaloids from Papaver somniferum. Due to the high flow rates allowed with the monolithic column and the inherent selectivity of the chemiluminescence reactions, the four predominant alkaloids - morphine, codeine, oripavine and thebaine - were determined in less than 2 min. The results obtained with numerous process samples compared favourable with those of the standard HPLC methodology. Limits of detection were 1 x 10{sup -10} M, 5 x 10{sup -10} M, 5 x 10{sup -10} M and 1 x 10{sup -9} M, for morphine, codeine, oripavine and thebaine, respectively.

  18. Rapid resolution liquid chromatography (RRLC) analysis for quality control of Rhodiola rosea roots and commercial standardized products.

    Science.gov (United States)

    Ma, Yuan-Chun; Wang, Xiao-Qiang; Hou, Fei Fei; Ma, Jie; Luo, Mai; Lu, Shane; Jin, Peter; Terevsky, Nelly; Chen, Alice; Xu, Iris; Patel, Asmita V; Gorecki, Dariusz

    2011-05-01

    A simple, sensitive and reliable reversed phase Rapid Resolution Liquid Chromatography (RRLC) method was developed and validated for six biologically active compounds (salidroside, tyrosol, rosarin, rosavin, rosin and rosiridin) in Rhodiola rosea L. roots and powder extracts. The method uses a Phenomenex C18 (2)-HST column at 40 degrees C with a neutral gradient system mobile phase (H20 and acetonitrile), a flow rate of 1.0 mL/min, and UV detection wavelengths set at 205 and 254 nm, simultaneously. Baseline separation of the six active compounds was achieved within 8 minutes. The average percentages of rosavins (rosarin, rosavin, and rosin) in authentic R. rosea roots and root powder extracts were quantitatively determined and a characteristic R. rosea roots RRLC profile was established. The RRLC method is accurate and sensitive; in addition, it effectively increases the sample analysis throughput compared with conventional HPLC.

  19. Fully validated method for rapid and simultaneous measurement of six antiepileptic drugs in serum and plasma using ultra-performance liquid chromatography-electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Kuhn, Joachim; Knabbe, Cornelius

    2013-06-15

    Therapeutic drug monitoring (TDM) may be very useful in the clinical management of antiepileptic drug therapy for multiple reasons, such as individual variability, metabolism, genetic factors or drug-drug or drug-food interactions. In addition, TDM is helpful to study the variation in pharmacokinetics that occurs between individuals. Here, we describe a rapid assay using ultra-performance liquid chromatography-electrospray ionization tandem mass spectrometry to measure the antiepileptic drugs lacosamide, lamotrigine, levetiracetam, primidone, topiramate, and zonisamide. After the addition of internal standards (ISs) and protein precipitation of serum or plasma, 1 μl of sample was separated on a 2.1×50 mm reverse phase column (Waters, Acquity UPLC BEH Phenyl, 1.7 μm). Analytes were then ionized and detected by electrospray ionization mass spectrometry with multiple reaction monitoring. Runtime was 2.5 min per injection. Matrix effects were investigated by systematical ion suppression and in-source fragmentation experiments. The calibration curves of the 6 antiepileptic drugs were linear over the working range between 0.05 and 50 mg/L (r>0.99). The limit of detection (LOD) was measured in the assay. The intraassay and interassay coefficients of variation for all compounds were 1.0 mg/L). Mean recoveries were between 87.8 and 98.6% for all drugs. There were no significant ion suppressions detected at the elution times of the analytes. The mean differences between serum and heparinized plasma values were less than 6% for the 6 antiepileptic drugs. All drugs were stable in serum at -20°C, 4°C, and even at RT for at least 1 month. In summary, a specific and sensitive stable isotope dilution UPLC-MS/MS method was developed and validated for routine clinical monitoring of lacosamide, lamotrigine, levetiracetam, primidone, topiramate, and zonisamide. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. Rapid simultaneous determination of paracetamol, amantadine hydrochloride, caffeine and chlorpheniramine maleate in human plasma by liquid chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Feng, Shudan; Tian, Yuan; Zhang, Zunjian; Zhang, Jingjing; Huang, Meihua; Chen, Yun

    2009-01-01

    A rapid, simple and sensitive high performance liquid chromatography with positive ion electrospray ionization tandem mass spectrometry (HPLC-ESI-MS/MS) was first developed and validated to simultaneously determine paracetamol (PAR, CAS 103-90-2), amantadine hydrochloride (ATH, CAS 665-66-7), caffeine (CAF, CAS 58-08-2) and chlorpheniramine maleate (CPM, CAS 113-92-8) in human plasma using tramadol hydrochloride (TMH, CAS 22204-88-2) as internal standard (IS). Following methanol-induced protein precipitation, the analytes were separated using a mobile phase comprised of methanol:water (0.5% formic acid) = 20:80 (v/v) on a commercially available column (150 mm x 2.1 mm I.D., 5 microm) and analyzed by electrospray ionization tandem mass spectrometry in the selected reaction monitoring (SRM) mode with the precursor to product ion transitions m/z 152.3-->110.2 for PAR, 152.3-->135.3 for ATH, 195.1-->138.3 for CAF, 275.2-->230.3 for CPM and 264.2-->58.2 for TMH. The standard curves were linear (r2 > 0.99) over the concentration range of 0.2-20 microg/mL for PAR, 20-2000 ng/mL for ATH and CAF, 0.1-10 ng/mL for CPM and had good accuracy and precision, respectively. The within- and between-batch precisions were less than 15% in terms of relative standard deviation (RSD). The lower limit of quantitation (LLOQ) were 0.2 microg/mL, 20 ng/mL, 20 ng/mL and 0.1 ng/mL for PAR, ATH, CAF and CPM, respectively. The described method has been successfully applied to study the pharmacokinetics of paracetamol-amantadine hydrochloride tablets in Chinese healthy male volunteers with great precision and sensitivity.

  1. Simple and rapid method for the isolation of forskolin from Coleus forskohlii by charcoal column chromatography.

    Science.gov (United States)

    Saleem, A M; Dhasan, P B; Rafiullah, M R M

    2006-01-06

    A simple, safe, rapid and economical method was developed for the isolation of high-purity forskolin from Coleus forskohlii roots using activated charcoal as an adsorbent in a column. The elution was carried out under reduced pressure to make the process rapid. Activated charcoal acted as a reversed phase adsorbent and allowed elution of forskolin without much impurities. The residue, obtained from the eluate was purified and crystallized using different solvent mixtures to obtain pure forskolin. The forskolin isolated was analyzed and characterized by UV, IR, RP-HPLC, electrospray ionization MS, 1H NMR and 13C NMR. The yield was 0.097% w/w (RSD 5.6%). The purity was 96.9% w/w (RSD 0.3%) as determined by RP-HPLC. The present method enables researchers to produce high-purity forskolin in their labs by using common chemicals.

  2. Rapid confirmatory analysis of non-steroidal anti-inflammatory drugs in bovine milk by rapid resolution liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Dowling, Geraldine; Gallo, Pasquale; Malone, Edward; Regan, Liam

    2009-11-13

    A rapid method has been developed to analyse carprofen (CPF), diclofenac (DCF), mefenamic acid (MFN), niflumic acid (NIFLU), naproxen (NAP), oxyphenylbutazone (OXYPHEN), phenylbutazone (PBZ) and suxibuzone (SUXI) residues in bovine milk. Milk samples are extracted with acetonitrile and sample extracts were purified on Evolute ABN solid phase extraction cartridges. Aliquots were analysed by rapid resolution liquid chromatography tandem mass spectrometry (RRLC-MS/MS) with a runtime of 6.5 min. The method was validated in bovine milk, according to the criteria defined in Commission Decision 2002/657/EC. CCalpha values of 0.46, 1.08, 0.92, 1.26, 1.29, 2.12, 0.55 and 2.86 ng mL(-1) were determined for CPF, DCF, MFN, NIFLU, NAP, OXYPHEN, PBZ and SUXI, respectively. CCbeta values of 0.79, 1.85, 1.56, 2.15, 2.19, 3.62, 0.94 and 4.87 ng mL(-1) were determined for CPF, DCF, MFN, NIFLU, NAP, OXYPHEN, PBZ and SUXI, respectively. The measurement uncertainty of the method was estimated at 9, 28, 28, 45, 46, 45, 10 and 39% for CPF, DCF, MFN, NIFLU, NAP, OXYPHEN, PBZ and SUXI. Fortifying bovine milk samples (n=18) in three separate assays, show the accuracy of the method to be between 82 and 108%. The precision of the method, expressed as RSD values for the within-lab reproducibility at the three levels of fortification (5, 7.5 and 10 ng mL(-1)) was less than 16%, respectively. The advantage of the method is that low ng mL(-1) levels can be detected and quantitatively confirmed rapidly in milk and that 3 batches of samples can be analysed within a single day using RRLC-MS/MS with a runtime of 6.5 min.

  3. Rapid Preconcentration for Liquid Chromatography-Mass Spectrometry Assay of Trace Level Neuropeptides

    Science.gov (United States)

    Zhou, Ying; Mabrouk, Omar S.; Kennedy, Robert T.

    2013-11-01

    Measurement of neuropeptides in the brain through in vivo microdialysis sampling provides direct correlation between neuropeptide concentration and brain function. Capillary liquid chromatography-multistage mass spectrometry (CLC-MSn) has proven to be effective at measuring endogenous neuropeptides in microdialysis samples. In the method, microliter samples are concentrated onto nanoliter volume packed beds before ionization and mass spectrometry analysis. The long times required for extensive preconcentration present a barrier to routine use because of the many samples that must be analyzed and instability of neuropeptides. In this study, we evaluated the capacity of 75 μm inner diameter (i.d.) capillary column packed with 10 μm reversed phase particles for increasing the throughput in CLC-MSn based neuropeptide measurement. Coupling a high injection flow rate for fast sample loading/desalting with a low elution flow rate to maintain detection sensitivity, this column has reduced analysis time from ˜30 min to 3.8 min for 5 μL sample, with 3 pM limit of detection (LOD) for enkephalins and 10 pM LOD for dynorphin A1-8 in 5 μL sample. The use of isotope-labeled internal standard lowered peptide signal variation to less than 5 %. This method was validated for in vivo detection of Leu and Met enkephalin with microdialysate collected from rat globus pallidus. The improvement in speed and stability makes CLC-MSn measurement of neuropeptides in vivo more practical.

  4. Rapid screening and characterisation of antioxidants of Cosmos caudatus using liquid chromatography coupled with mass spectrometry.

    Science.gov (United States)

    Shui, Guanghou; Leong, Lai Peng; Wong, Shih Peng

    2005-11-15

    Ulam raja (Cosmos caudatus) is used traditionally for improving blood circulation. In this study, it was found that ulam raja had extremely high antioxidant capacity of about 2,400 mg l-ascorbic acid equivalent antioxidant capacity (AEAC) per 100 g of fresh sample. Antioxidant peaks in extract of ulam raja were firstly characterized using free radical spiking test through high performance liquid chromatography coupled with mass spectrometry (MS). Upon reaction with 2,2'-azino-bis-(3-ethylbenzothiazoline-6-sulfonic acid) (ABTS) free radicals, intensities of antioxidant peaks will be significantly reduced. HPLC/MS(n) was further applied to elucidate the chemical structures of antioxidant peaks characterized in the spiking test. More than twenty antioxidants were identified in ulam raja, and their chemical structures were proposed. The major antioxidants in ulam raja were attributed to a number of proanthocyanidins that existed as dimers through hexamers, quercetin glycosides, chlorogenic, neo-chlorogenic, crypto-chlorogenic acid and (+)-catching. High content of antioxidants antioxidants contained in ulam raja could be partly responsible for its ability to reduce oxidative stress.

  5. Rapid characterization of biotherapeutic proteins by size-exclusion chromatography coupled to native mass spectrometry.

    Science.gov (United States)

    Haberger, Markus; Leiss, Michael; Heidenreich, Anna-Katharina; Pester, Oxana; Hafenmair, Georg; Hook, Michaela; Bonnington, Lea; Wegele, Harald; Haindl, Markus; Reusch, Dietmar; Bulau, Patrick

    2016-01-01

    High-molecular weight aggregates such as antibody dimers and other side products derived from incorrect light or heavy chain association typically represent critical product-related impurities for bispecific antibody formats. In this study, an approach employing ultra-pressure liquid chromatography size-exclusion separation combined with native electrospray ionization mass spectrometry for the simultaneous formation, identification and quantification of size variants in recombinant antibodies was developed. Samples exposed to storage and elevated temperature(s) enabled the identification of various bispecific antibody size variants. This test system hence allowed us to study the variants formed during formulation and bio-process development, and can thus be transferred to quality control units for routine in-process control and release analytics. In addition, native SEC-UV/MS not only facilitates the detailed analysis of low-abundant and non-covalent size variants during process characterization/validation studies, but is also essential for the SEC-UV method validation prior to admission to the market.

  6. Rapid Analysis of Cefazolin in Serum by High-Pressure Liquid Chromatography

    Science.gov (United States)

    Wold, John S.

    1977-01-01

    A high-pressure liquid chromatography (HPLC) method has been developed for the analysis of cefazolin in serum. Serum was deproteinized by the addition of 6% trichloroacetic acid and injected onto a reverse-phase column with a mobile phase of 10 to 15% methanol in 1% aqueous acetic acid. Cefazolin chromatographed without interference from ultraviolet-absorbing components of serum, with a retention time of 3.1 min. Standard curves comparing peak area with concentration prepared from dog or human sera were linear over a range of 1.6 to 200 μg/ml. Results from the HPLC assay were compared with microbiological assays (cylinder plate method) on both standard serum samples and sera from dogs and human subjects receiving intramuscular cefazolin. The HPLC method was somewhat more accurate in comparison with the microbiological assay performed on serum samples of known concentration. The comparison of results from an analysis of serum levels of dogs or human subjects receiving cefazolin indicated that the two methods would lead to identical conclusions concerning pharmacokinetics or the achievement of therapeutic serum levels. The HPLC assay method presents an alternative to conventional microbiological assays, with marked improvement in speed (30 min) and considerable potential for future development. PMID:836007

  7. Ion-exchange chromatography: basic principles and application to the partial purification of soluble mammalian prolyl oligopeptidase.

    Science.gov (United States)

    Cummins, Philip M; Dowling, Oonagh; O'Connor, Brendan F

    2011-01-01

    Ion-exchange chromatography (IEC) allows for the separation of ionizable molecules on the basis of differences in charge properties. Its large sample-handling capacity, broad applicability (particularly to proteins and enzymes), moderate cost, powerful resolving ability, and ease of scale-up and automation have led to it becoming one of the most versatile and widely used of all liquid chromatography (LC) techniques. In this chapter, we review the basic principles of IEC, as well as the broader criteria for selecting IEC conditions. By way of further illustration, we outline protocols necessary to partially purify a serine peptidase from bovine whole brain cytosolic fraction, covering crude tissue extract preparation through to partial purification of the target enzyme using anion-exchange chromatography. Protocols for assaying total protein and enzyme activity in both pre- and post-IEC fractions are also described. The target serine peptidase, prolyl oligopeptidase (POP, EC3.4.21.26), is an 80-kDa enzyme with endopeptidase activity towards peptide substrates of ≤30 amino acids. POP is a ubiquitous post-proline cleaving enzyme with particularly high expression levels in the mammalian brain, where it participates in the metabolism of neuroactive peptides and peptide-like hormones (e.g. thyroliberin, gonadotropin-releasing hormone).

  8. Purification of recombinant virus-like particles of porcine circovirus type 2 capsid protein using ion-exchange monolith chromatography.

    Science.gov (United States)

    Zaveckas, Mindaugas; Snipaitis, Simas; Pesliakas, Henrikas; Nainys, Juozas; Gedvilaite, Alma

    2015-06-01

    Diseases associated with porcine circovirus type 2 (PCV2) infection are having a severe economic impact on swine-producing countries. The PCV2 capsid (Cap) protein expressed in eukaryotic systems self-assemble into virus-like particles (VLPs) which can serve as antigens for diagnostics or/and as vaccine candidates. In this work, conventional adsorbents as well as a monolithic support with large pore sizes were examined for the chromatographic purification of PCV2 Cap VLPs from clarified yeast lysate. Q Sepharose XL was used for the initial separation of VLPs from residual host nucleic acids and some host cell proteins. For the further purification of PCV2 Cap VLPs, SP Sepharose XL, Heparin Sepharose CL-6B and CIMmultus SO3 monolith were tested. VLPs were not retained on SP Sepharose XL. The purity of VLPs after chromatography on Heparin Sepharose CL-6B was only 4-7% and the recovery of VLPs was 5-7%. Using ion-exchange chromatography on the CIMmultus SO3 monolith, PCV2 Cap VLPs with the purity of about 40% were obtained. The recovery of VLPs after chromatography on the CIMmultus SO3 monolith was 15-18%. The self-assembly of purified PCV2 Cap protein into VLPs was confirmed by electron microscopy. Two-step chromatographic purification procedure of PCV2 Cap VLPs from yeast lysate was developed using Q Sepharose XL and cation-exchange CIMmultus SO3 monolith. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Organic analysis by ion chromatography. 1. Determination of aromatic amines and aromatic diisocyanates by cation-exchange chromatography with amperometric detection.

    Science.gov (United States)

    Zhu, Yan; Wang, Muhua; Du, Huangyong; Wang, Fang; Mou, Shifen; Haddad, Paul R

    2002-05-17

    A method has been developed for the simultaneous determination of a range of aromatic amines using cation-exchange chromatography performed on a standard ion chromatography column using d.c. amperometric detection. The analytes separated were 2,4- and 2,6-toluenediamine (2,4- and 2,6-TDA), aniline, o-toluidine, benzidine, p-chloroaniline, 4,4'-diaminodiphenyl (4,4'-DDP), m-nitroaniline and 1-naphthylamine. A Dionex CS12 column was used with gradient elution from an initial eluent of 5% CH3CN+35 mM H2SO4 to 27% CH3CN+35 mM H2SO4 (at 35 min). Detection limits in the range 2.6-22.6 microg/l were observed for all analytes except m-nitroaniline, for which the detection limit was 201 microg/l. Linear calibrations and good precision were observed and the method was applied to the determination of benzidine, p-chloroaniline and 1-naphthylamine in wastewater samples. Further, the separation was also used (after some modification of the eluent conditions) for the determination of 2,4- and 2,6-toluene diisocyanate (2,4- and 2,6-TDI) and 4,4'-methylenediphenyl diisocyanate (4,4'-MDI) after their hydrolysis to 2,4-TDA, 2,6-TDA and 4,4'-DDP. Detection limits for 2,6- and 2,4-TDI and 4,4'-MDI were 3.8, 8.2, and 11.2 microg/l, respectively. The method was applied to the determination of diisocyanates in air.

  10. Characterization of phenolic compounds in coal tar by gas chromatography/negative-ion atmospheric pressure chemical ionization mass spectrometry.

    Science.gov (United States)

    Ma, Sutian; Ma, Chao; Qian, Kejun; Zhou, Yasong; Shi, Quan

    2016-08-15

    Phenolic compounds are commonly found in fossel fuels and bio-oils, and have a detrimental effect on the chemical stability of the fuels. A selective analytical method is needed to characterize the phenolic compounds in complex hydrocarbon mixtures. Gas chromatography/atmospheric pressure chemical ionization mass spectrometry (GC/APCI-MS) was used to characterize the phenolic compounds in a low-temperature coal tar and its narrow distillate fractions. Negative-ion APCI selectively ionized phenolic compounds in the coal tar. The [M-H](-) and [M-H + O](-) ions were derived from monohydric phenols, while [M-H](-) , [M-2H](-) , and [M-2H + O](-) were from benzenediols. Monohydric phenolic compounds with 1-4 aromatic rings and some dihydric phenolic compounds were identified. The results from GC/APCI-MS were validated by those from negative electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (ESI FTICRMS). Negative-ion GC/APCI-MS was proposed and successfully used to characterize phenolic compounds in coal tar samples. This technique can potentially be used for the characterization of phenolic compounds in other complex hydrocarbon systems. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  11. Confirmation of clorsulon residues in cattle kidney by capillary gas chromatography-negative-ion chemical-ionization mass spectrometry.

    Science.gov (United States)

    Wehner, T A; Wood, J S; Walker, R; Downing, G V; Vandenheuvel, W J

    1987-07-24

    A confirmatory assay for residues of the anthelmintic agent clorsulon [4-amino-6-(trichloroethenyl)-1,3-benzenedisulfonamide] in cattle kidney tissue has been developed. The assay involves isolation of a drug-containing fraction by solvent extraction, methylation of the analyte, and fused-silica capillary column gas chromatography-negative-ion chemical-ionization mass spectrometry of the pentamethyl derivative of clorsulon. The intensities of four negative ions [m/z 406 and 408 (trichloro species) and m/z 413 and 415 (dichloro species)] are monitored. Confirmation of the presence of drug in an analyte requires that all four ions appear at the appropriate retention time with their intensity ratios within 10-15% of those arising from analysis of the reference standard, methylated clorsulon; the lower limit of detection is 3 ppb. Quantification of the drug is based on the intensity of the m/z 406 ion. Identification and quantification of residues by the gas chromatographic-mass spectrometric assay gave results in good agreement with those obtained with an electron-capture gas chromatographic assay.

  12. [Rapid screening of fipronil and its metabolites in egg and egg products by solid phase extraction-liquid chromatography-quadrupole time-of-flight mass spectrometry].

    Science.gov (United States)

    Guo, Dehua; Shi, Yiyin; Li, You; Yi, Xionghai; Deng, Xiaojun; Xiao, Wenqing; Wang, Jian; Li, Xiao; Liu, Han; Shen, Weijian

    2017-12-08

    A method for rapid screening of fipronil and its metabolites in egg and egg products was developed by liquid chromatography coupled with quadrupole time-of-flight mass spectrometry (LC-QTOF MS). The samples were extracted by acid-acetonitrile, cleaned up by PRiME HLB SPE. The separation was performed on a Poroshell 120 EC C18 column (150 mm×3 mm, 2.7 μm) with gradient elution using water and acetonitrile as mobile phases. The target compounds were monitored under negative ionization mode with electrospray ionization (ESI) source and two databases of accurate mass and fragment ions were created. The matrix effects in four kinds of egg and egg products were considered and the quantification was carried out by internal standard method. The results demonstrated that the linear ranges were from 0.1 to 5 μg/L with good correlation coefficients (r2>0.99). The limits of detection (LODs, S/N>3) and limits of quantitation (LOQs, S/N>10) were 0.2 μg/kg and 1 μg/kg, respectively. The recoveries of fipronil and its metabolites in different matrixes spiked with 1, 2 and 5 μg/kg varied from 82.6%-98.1%, and the relative standard deviations (RSDs) were between 3.8%-9.9% (n=6). The method can effectively correct the ionization suppression. It is sensitive, accurate and suitable for the rapid screening of fipronil, fipronil sulfide, fipronil sulfone and fipronil desulfinyl in egg, egg noodle, cake and mayonnaise.

  13. Simultaneous determination of artificial sweeteners, preservatives, caffeine, theobromine and theophylline in food and pharmaceutical preparations by ion chromatography.

    Science.gov (United States)

    Chen, Q C; Wang, J

    2001-12-07

    A novel ion chromatographic method was proposed for the simultaneous determination of artificial sweeteners (sodium saccharin, aspartame, acesulfame-K), preservatives (benzoic acid, sorbic acid), caffeine, theobromine and theophylline. The separation was performed on an anion-exchange analytical column operated at 40 degrees C within 45 min by an isocratic elution with 5 mM aqueous NaH2PO4 (pH 8.20) solution containing 4% (v/v) acetonitrile as eluent, and the determination by wavelength-switching ultraviolet absorbance detection. The detection limits (signal-to-noise ratio 3:1) for all analytes were below the sub-microg/ml level. Under the experimental conditions, several organic acids, including citric acid, malic acid, tartaric acid and ascorbic acid, did not interfere with the determination. The method has been successfully applied to the analysis of various food and pharmaceutical preparations, and the average recoveries for real samples ranged from 85 to 104%. The levels of all analytes determined by this method were in good agreement with those obtained by the high-performance liquid chromatographic procedure. The results also indicated that ion chromatography would be possibly a beneficial alternative to conventional high-performance liquid chromatography for the separation and determination of these compounds.

  14. Rapid chiral separation and impurity determination of levofloxacin by ligand-exchange chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Yan, Hongyuan [Center for Advanced Bioseparation Technology, Department of Chemical Engineering, Inha University, Incheon 402-751 (Korea, Republic of); Row, Kyung Ho [Center for Advanced Bioseparation Technology, Department of Chemical Engineering, Inha University, Incheon 402-751 (Korea, Republic of)]. E-mail: rowkho@inha.ac.kr

    2007-02-12

    A sensitive, simple, and accurate method for determination of levofloxacin and its (R)-enantiomer was developed to determine the chiral impurity of levofloxacin in Cravit Tablets material by ligand-exchange high performance liquid chromatography. The effects of different kinds of ligands, concentration of ligands in mobile phase, organic modifier, pH of mobile phase, and temperature on enantioseparation were investigated and evaluated. Chiral separation was performed on a conventional C{sub 18} column, where the mobile phase consisted of a methanol-water solution (containing10 mmol L{sup -1} L-leucine and 5 mmol L{sup -1} copper sulfate) (88:12, v/v) and its flow-rate was set at 1.0 mL min{sup -1}. The conventional C{sub 18} column offers baseline separation of two enantiomers with a resolution of 2.4 in less than 20 min. Thermodynamic data ({delta}{delta}H and {delta}{delta}S) obtained by Van't Hoff plots revealed the chiral separation is an enthalpy-controlled process. The standard curves showed excellent linearity over the concentration range from 0.5 to 400 mg L{sup -1} for levofloxacin and its (R)-enantiomer. The linear correlation equations are: y = 1.33 x 10{sup 5} x + 6297 (r = 0.9991) and y = 1.34 x 10{sup 5} x + 3565 (r = 0.9997), respectively. The relative standard deviation (RSD) of the method was below 2.3% (n = 3)

  15. Determination of major sodium iodide symporter (NIS) inhibitors in drinking waters using ion chromatography with conductivity detector.

    Science.gov (United States)

    Cengiz, Mehmet Fatih; Bilgin, Ayse Kevser

    2016-02-20

    Goiter is an important health problem all over the world and iodine deficiency is its most common cause. Perchlorate, thiocyanate and nitrate (called as major NIS inhibitors) are known to competitively inhibit iodide uptake by the thyroid gland and thus, human exposure to major NIS inhibitors is a public health concern. In this study, an ion chromatographic method for the determination of most common NIS inhibitor ions in drinking waters was developed and validated. This is the first study where an analytical method is used for the determination of major NIS inhibitors in drinking water by an ion chromatography system in a single run. Chromatographic separations were achieved with an anion-exchange column and separated ions were identified by a conductivity detector. The method was found to be selective, linear, precise accurate and true for all of interested ions. The limits of the detections (LOD) were estimated at 0.003, 0.004 and 0.025mgL(-1) for perchlorate, thiocyanate and nitrate, respectively. Possible interference ions in drinking waters were examined for the best separation of NIS inhibitors. The excellent method validation data and proficiency test result (Z-score for nitrate: -0.1) of the FAPAS(®) suggested that the developed method could be applied for determination of NIS inhibitor residues in drinking waters. To evaluate the usefulness of the method, 75 drinking water samples from Antalya/Turkey were analyzed for NIS inhibitors. Perchlorate concentrations in the samples ranged from not detected (less than LOD) to 0.07±0.02mgL(-1) and the range of nitrate concentrations were found to be 3.60±0.01mgL(-1) and 47.42±0.40mgL(-1). No thiocyanate residues were detected in tested drinking water samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. [Rapid determination of ethanol in blood by capillary-gas chromatography].

    Science.gov (United States)

    Ren, Lin; Sun, Cheng-jun; Zou, Xiao-li; Zeng, Hong-yan; Jiang, Bo

    2010-11-01

    To develop a method for the rapid determination of ethanol in blood with capillary-GC. 0.50 mL of whole blood sample was taken and added with 1.00 mL of dimethyl sulfoxide (DMSO), and 2 g of anhydrous sodium sulfate. The supernatant of the sample solution was directly injected into GC for analysis. Ethanol was separated from other substances in the sample. The liner range of ethanol detected by the capillary-GC was 0.0-300.0 mg/100 mL, and the detection limit was 0.2 mg/100 mL. The RSD for standard solution determination was 1.36%. Satisfactory results were obtained for the determination of ethanol in whole blood samples, with recoveries ranging from 90.9% to 107.3% and a RSD of 1.98%. The combined uncertainty was 2.2%. This is a rapid, sensitive and simple method for determination of ethanol in large quantities of samples. The method has shortened the duration of analysis cycle in comparison with the traditional headspace-GC, with a reduction from 20-30 min to less than 10 min.

  17. Ion Torren Semiconductor Sequencing Allows Rapid, Low Cost Sequencing of the Human Exome ( 7th Annual SFAF Meeting, 2012)

    Energy Technology Data Exchange (ETDEWEB)

    Jenkins, David [EdgeBio

    2012-06-01

    David Jenkins on "Ion Torrent semiconductor sequencing allows rapid, low-cost sequencing of the human exome" at the 2012 Sequencing, Finishing, Analysis in the Future Meeting held June 5-7, 2012 in Santa Fe, New Mexico.

  18. Combined Yamamoto approach for simultaneous estimation of adsorption isotherm and kinetic parameters in ion-exchange chromatography.

    Science.gov (United States)

    Rüdt, Matthias; Gillet, Florian; Heege, Stefanie; Hitzler, Julian; Kalbfuss, Bernd; Guélat, Bertrand

    2015-09-25

    Application of model-based design is appealing to support the development of protein chromatography in the biopharmaceutical industry. However, the required efforts for parameter estimation are frequently perceived as time-consuming and expensive. In order to speed-up this work, a new parameter estimation approach for modelling ion-exchange chromatography in linear conditions was developed. It aims at reducing the time and protein demand for the model calibration. The method combines the estimation of kinetic and thermodynamic parameters based on the simultaneous variation of the gradient slope and the residence time in a set of five linear gradient elutions. The parameters are estimated from a Yamamoto plot and a gradient-adjusted Van Deemter plot. The combined approach increases the information extracted per experiment compared to the individual methods. As a proof of concept, the combined approach was successfully applied for a monoclonal antibody on a cation-exchanger and for a Fc-fusion protein on an anion-exchange resin. The individual parameter estimations for the mAb confirmed that the new approach maintained the accuracy of the usual Yamamoto and Van Deemter plots. In the second case, offline size-exclusion chromatography was performed in order to estimate the thermodynamic parameters of an impurity (high molecular weight species) simultaneously with the main product. Finally, the parameters obtained from the combined approach were used in a lumped kinetic model to simulate the chromatography runs. The simulated chromatograms obtained for a wide range of gradient lengths and residence times showed only small deviations compared to the experimental data. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Rapid Melt and Resolidification of Surface Layers Using Intense, Pulsed Ion Beams Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Renk, Timothy J.

    1998-10-02

    The emerging technology of pulsed intense ion beams has been shown to lead to improvements in surface characteristics such as hardness and wear resistance, as well as mechanical smoothing. We report hereon the use of this technology to systematically study improvements to three types of metal alloys - aluminum, iron, and titanium. Ion beam tieatment produces a rapid melt and resolidification (RMR) of the surface layer. In the case of a predeposited thin-fihn layer, the beam mixes this layer into the substrate, Ieading to improvements that can exceed those produced by treatment of the alloy alone, In either case, RMR results in both crystal refinement and metastable state formation in the treated surface layer not accessible by conventional alloy production. Although more characterization is needed, we have begun the process of relating these microstructural changes to the surface improvements we discuss in this report.

  20. Rapid analysis of water- and fat-soluble vitamins by electrokinetic chromatography with polymeric micelle as pseudostationary phase.

    Science.gov (United States)

    Ni, Xinjiong; Xing, Xiaoping; Cao, Yuhua; Cao, Guangqun

    2014-11-28

    A novel polymeric micelle, formed by random copolymer poly (stearyl methacrylate-co-methacrylic acid) (P(SMA-co-MAA)) has been used as pseudostationary phase (PSP) in electrokinetic chromatography (EKC) for simultaneous and rapid determination of 11 kinds of water- and fat-soluble vitamins in this work. The running buffer consisting of 1% (w/v) P(SMA-co-MAA), 10% (v/v) 1-butanol, 20% (v/v) acetonitrile, and 30 mM Palitzsch buffer solution (pH 9.2) was applied to improve the selectivity and efficiency, as well as to shorten analysis time. 1-Butanol and acetonitrile as the organic solvent modifiers played the most important roles for rapid separation of these vitamins. The effects of organic solvents on microstructure of the polymeric micelle were investigated. The organic solvents swell the polymeric micelle by three folds, lower down the surface charge density and enhance the microenviromental polarity of the polymeric micelle. The 11 kinds of water- and fat-soluble vitamins could be baseline separated within 13 min. The method was applied to determine water- and fat-soluble vitamins in commercial vitamin sample; the recoveries were between 93% and 111% with the relative standard derivations (RSDs) less than 5%. The determination results matched the label claim. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Optimization of Analytical Conditions for a Rapid Determination of Aniline in Environmental Water by Liquid Chromatography/Tandem Mass Spectrometry.

    Science.gov (United States)

    Furukawa, Koji; Hashimoto, Makoto; Kaneco, Satoshi

    2017-01-01

    A rapid determination of aniline in environmental water was examined based on liquid chromatography/tandem mass spectrometry (LC/MS/MS). Environmental water samples were diluted 20-fold with Mill-Q water and measured by LC/MS/MS after adding a surrogate substance (aniline-d5). In the results of the present study, the calibration curve of aniline showed good linearity in the range of 0.05 - 2.0 μg/L. Since the RSD (repeatability) by measuring repeatedly an aniline standard solution (0.05 μg/L, n = 7) was 3.2%, the repeatability of this work was very excellent. In addition, the recovery rate of aniline in environmental water was in the range of 99.0 - 102% with RSD 3.4 - 7.7%, and very good recovery test results were obtained. From these results, this analytical method was confirmed to be effective for aniline measurements of environmental water samples. Also, it is possible to conduct rapid analyses of aniline in environmental water without any solid-phase extraction process, compared to the solid-phase extraction-GC/MS method.

  2. A novel ion-exclusion chromatography-mass spectrometry method to measure concentrations and cycling rates of carbohydrates and amino sugars in freshwaters.

    Science.gov (United States)

    Horňák, Karel; Pernthaler, Jakob

    2014-10-24

    The concentrations of free neutral carbohydrates and amino sugars were determined in freshwater samples of distinct matrix complexity, including meso-, eu- and dystrophic lakes and ponds, using high-performance ion-exclusion chromatography (HPIEC) coupled to mass spectrometry (MS). In contrast to other methods, our approach allowed the quantification of free neutral carbohydrates and amino sugars at low nM concentrations without derivatization, de-salting or pre-concentration. New sample preparation procedures were applied prior to injection employing syringe and hollow fiber filtration. Analytes were separated on a strong cation exchange resin under 100% aqueous conditions using 0.1% formic acid as a mobile phase. To minimize background noise in MS, analytes were detected in a multiple reaction monitoring scan mode with double ion filtering. Detection limits of carbohydrates and amino sugars ranged between 0.2 and 2nM at a signal-to-noise ratio >5. Error ranged between 1 and 12% at 0.5-500nM levels. Using a stable isotope dilution approach, both the utilization and recycling of glucose in Lake Zurich was observed. In contrast, N-acetyl-glucosamine was equally rapidly consumed but there was no visible de novo production. The simple and rapid sample preparation makes our protocol suitable for routine analyses of organic compounds in freshwater samples. Application of stable isotope tracers along with accurate measures of carbohydrate and amino sugar concentrations enables novel insights into the compound in situ dynamics. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Validating a High Performance Liquid Chromatography-Ion Chromatography (HPLC-IC) Method with Conductivity Detection After Chemical Suppression for Water Fluoride Estimation.

    Science.gov (United States)

    Bondu, Joseph Dian; Selvakumar, R; Fleming, Jude Joseph

    2018-01-01

    A variety of methods, including the Ion Selective Electrode (ISE), have been used for estimation of fluoride levels in drinking water. But as these methods suffer many drawbacks, the newer method of IC has replaced many of these methods. The study aimed at (1) validating IC for estimation of fluoride levels in drinking water and (2) to assess drinking water fluoride levels of villages in and around Vellore district using IC. Forty nine paired drinking water samples were measured using ISE and IC method (Metrohm). Water samples from 165 randomly selected villages in and around Vellore district were collected for fluoride estimation over 1 year. Standardization of IC method showed good within run precision, linearity and coefficient of variance with correlation coefficient R2 = 0.998. The limit of detection was 0.027 ppm and limit of quantification was 0.083 ppm. Among 165 villages, 46.1% of the villages recorded water fluoride levels >1.00 ppm from which 19.4% had levels ranging from 1 to 1.5 ppm, 10.9% had recorded levels 1.5-2 ppm and about 12.7% had levels of 2.0-3.0 ppm. Three percent of villages had more than 3.0 ppm fluoride in the water tested. Most (44.42%) of these villages belonged to Jolarpet taluk with moderate to high (0.86-3.56 ppm) water fluoride levels. Ion Chromatography method has been validated and is therefore a reliable method in assessment of fluoride levels in the drinking water. While the residents of Jolarpet taluk (Vellore distict) are found to be at a high risk of developing dental and skeletal fluorosis.

  4. Suspect screening of halogenated carboxylic acids in drinking water using ion exchange chromatography - high resolution (Orbitrap) mass spectrometry (IC-HRMS).

    Science.gov (United States)

    Gallidabino, Matteo D; Hamdan, Laurence; Murphy, Bronagh; Barron, Leon P

    2018-02-01

    Retrospective in silico screening of analytical data for the identification of new or emerging disinfection by-products in drinking waters could be useful to assess quality and potential hazards, as well as help implement mitigation procedures more rapidly. Herein, the first study coupling ion exchange chromatography (IC) with high resolution mass spectrometry (HRMS) for the determination of halogenated carboxylic acid disinfectant by-products is reported. Separation was achieved using a Metrohm A Supp 5 column and a Na2CO3/NaHCO3 gradient eluent from 1/0.31 to 10/3.1mM. A variety of solid phase extraction (SPE) sorbents were tested for added selectivity to organic ions and Isolute ENV+ cartridges were selected because of their best overall extraction performance. Method LODs were in the μgL-1 concentration range, with R2 ≥ 0.99 for all the analytes, and isobaric ions could be easily discriminated using HRMS. The method was applied to municipal drinking water. Targeted quantitative analysis revealed the presence of 10 haloacetic acids at levels not exceeding the limits set by WHO and USEPA. Furthermore, suspect screening for additional halogenated carboxylic acids via retrospective HRMS data analysis also indicated the presence of other iodinated HAAs and chlorinated propionic acids, of which one (i.e. monochloropropionic acid) is discussed here for the first time. Most importantly, several potential suspects could be eliminated from further consideration through HRMS data analysis alone. To our knowledge, this represents the first time that a retrospective IC-HRMS screen of halogenated carboxylic acids in drinking water has been reported. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Comprehensive lipidomic analysis of human plasma using multidimensional liquid- and gas-phase separations: Two-dimensional liquid chromatography-mass spectrometry vs. liquid chromatography-trapped-ion-mobility-mass spectrometry.

    Science.gov (United States)

    Baglai, Anna; Gargano, Andrea F G; Jordens, Jan; Mengerink, Ynze; Honing, Maarten; van der Wal, Sjoerd; Schoenmakers, Peter J

    2017-12-29

    Recent advancements in separation science have resulted in the commercialization of multidimensional separation systems that provide higher peak capacities and, hence, enable a more-detailed characterization of complex mixtures. In particular, two powerful analytical tools are increasingly used by analytical scientists, namely online comprehensive two-dimensional liquid chromatography (LC×LC, having a second-dimension separation in the liquid phase) and liquid chromatography-ion mobility-spectrometry (LC-IMS, second dimension separation in the gas phase). The goal of the current study was a general assessment of the liquid-chromatography-trapped-ion-mobility-mass spectrometry (LC-TIMS-MS) and comprehensive two-dimensional liquid chromatography-mass spectrometry (LC×LC-MS) platforms for untargeted lipid mapping in human plasma. For the first time trapped-ion-mobility spectrometry (TIMS) was employed for the separation of the major lipid classes and ion-mobility-derived collision-cross-section values were determined for a number of lipid standards. The general effects of a number of influencing parameters have been inspected and possible directions for improvements are discussed. We aimed to provide a general indication and practical guidelines for the analyst to choose an efficient multidimensional separation platform according to the particular requirements of the application. Analysis time, orthogonality, peak capacity, and an indicative measure for the resolving power are discussed as main characteristics for multidimensional separation systems. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Rapid Determination of Plutonium Isotopes in Environmental Samples Using Sequential Injection Extraction Chromatography and Detection by Inductively Coupled Plasma Mass Spectrometry

    DEFF Research Database (Denmark)

    Qiao, Jixin; Hou, Xiaolin; Roos, Per

    2009-01-01

    This article presents an automated method for the rapid determination of 239Pu and 240Pu in various environmental samples. The analytical method involves the in-line separation of Pu isotopes using extraction chromatography (TEVA) implemented in a sequential injection (SI) network followed by det...

  7. An on-line normal-phase high performance liquid chromatography method for the rapid detection of radical scavengers in non-polar food matrixes

    NARCIS (Netherlands)

    Zhang, Q.; van der Klift, E.J.C.; Janssen, H.-G.; van Beek, T.A.

    2009-01-01

    An on-line method for the rapid pinpointing of radical scavengers in non-polar mixtures like vegetable oils was developed. To avoid problems with dissolving the sample, normal-phase chromatography on bare silica gel was used with mixtures of hexane and methyl tert-butyl ether as the eluent. The high

  8. Quantitative analysis of cytokinins in plants by high performance liquid chromatography: electronspray ionization ion trap mass spectrometry.

    Science.gov (United States)

    Chen, Weiqi; Gai, Ying; Liu, Shichang; Wang, Renxiao; Jiang, Xiangning

    2010-10-01

    The present paper introduces a highly sensitive and selective method for simultaneous quantification of 12 cytokinins (free form and their conjugates). The method includes a protocol of extraction with methanol/water/formic acid (15/4/1, v/v/v) to the micro-scale samples, pre-purification with solid phase extraction (SPE) cartridges of the extracts, separation with a high performance liquid chromatography (HPLC) and detection by an electrospray ionization ion trap mass spectrometry (ESI-Ion trap-MS) system in a consecutive ion monitoring (CRM) mode at the three stage fragmentation of mass spectrometry (MS(3) ). The lowest detection level of the cytokinins of the method reaches 0.1-2.0 pg with a very wide range of linear regression from 1-512 pg, at the coefficient factors of 0.98-0.99. The feasibility of this method has been proven in the application of the method to the analysis of the trace-amount contents of cytokinins in the micro-scale samples of various types of plant materials, such as aerial parts of rice and poplar leaves etc. 12 endogenous cytokinins had been identified and quantified in the plant tissues, with an acceptable relatively higher recovery rate from 40% to 70%. © 2010 Institute of Botany, Chinese Academy of Sciences.

  9. Determination of trace inorganic anions in weak acids by single-pump column-switching ion chromatography.

    Science.gov (United States)

    Zhu, Haibao; Chen, Huadong; Zhong, Yingying; Ren, Dandan; Qian, Yaling; Tang, Hongfang; Zhu, Yan

    2010-08-01

    Ion chromatography has been proposed for the determination of three common inorganic anions (chloride, nitrate, and sulfate) in nine weak acids (tartaric acid, citric acid, formic acid, acetic acid, metacetonic acid, butyric acid, butanedioic acid, hexafluorophosphoric acid, and salicylic acid) using a single pump, two valves, a single eluent, and a single conductivity detector. The present system uses ion exclusion, concentrator, and anion-exchange columns connected in series via 6-port and 10-port valves in a Dionex ICS-2100 ion chromatograph. The valves were switched for the determination of three inorganic anions from weak acids in a single chromatographic run. Sample matrices of weak acids with a series of concentrations can be investigated. Complete separations of the previously mentioned anions are demonstrated within 40 min. Under the optimum conditions, the relative standard deviation values ranged from 1.3 to 3.8%. The detection limits of the three inorganic anions (S/N = 3) were in the range of 0.3-1.7 microg/L. The recoveries were in the range of 75.2-117.6%. With this system, automation for routine analysis, short analysis time, and low cost can be achieved.

  10. Nanofiber Ion-Exchange Membranes for the Rapid Uptake and Recovery of Heavy Metals from Water

    Directory of Open Access Journals (Sweden)

    Nithinart Chitpong

    2016-12-01

    Full Text Available An evaluation of the performance of polyelectrolyte-modified nanofiber membranes was undertaken to determine their efficacy in the rapid uptake and recovery of heavy metals from impaired waters. The membranes were prepared by grafting poly(acrylic acid (PAA and poly(itaconic acid (PIA to cellulose nanofiber mats. Performance measurements quantified the dynamic ion-exchange capacity for cadmium (Cd, productivity, and recovery of Cd(II from the membranes by regeneration. The dynamic binding capacities of Cd(II on both types of nanofiber membrane were independent of the linear flow velocity, with a residence time of as low as 2 s. Analysis of breakthrough curves indicated that the mass flow rate increased rapidly at constant applied pressure after membranes approached equilibrium load capacity for Cd(II, apparently due to a collapse of the polymer chains on the membrane surface, leading to an increased porosity. This mechanism is supported by hydrodynamic radius (Rh measurements for PAA and PIA obtained from dynamic light scattering, which show that Rh values decrease upon Cd(II binding. Volumetric productivity was high for the nanofiber membranes, and reached 0.55 mg Cd/g/min. The use of ethylenediaminetetraacetic acid as regeneration reagent was effective in fully recovering Cd(II from the membranes. Ion-exchange capacities were constant over five cycles of binding-regeneration.

  11. Nanofiber Ion-Exchange Membranes for the Rapid Uptake and Recovery of Heavy Metals from Water

    Science.gov (United States)

    Chitpong, Nithinart; Husson, Scott M.

    2016-01-01

    An evaluation of the performance of polyelectrolyte-modified nanofiber membranes was undertaken to determine their efficacy in the rapid uptake and recovery of heavy metals from impaired waters. The membranes were prepared by grafting poly(acrylic acid) (PAA) and poly(itaconic acid) (PIA) to cellulose nanofiber mats. Performance measurements quantified the dynamic ion-exchange capacity for cadmium (Cd), productivity, and recovery of Cd(II) from the membranes by regeneration. The dynamic binding capacities of Cd(II) on both types of nanofiber membrane were independent of the linear flow velocity, with a residence time of as low as 2 s. Analysis of breakthrough curves indicated that the mass flow rate increased rapidly at constant applied pressure after membranes approached equilibrium load capacity for Cd(II), apparently due to a collapse of the polymer chains on the membrane surface, leading to an increased porosity. This mechanism is supported by hydrodynamic radius (Rh) measurements for PAA and PIA obtained from dynamic light scattering, which show that Rh values decrease upon Cd(II) binding. Volumetric productivity was high for the nanofiber membranes, and reached 0.55 mg Cd/g/min. The use of ethylenediaminetetraacetic acid as regeneration reagent was effective in fully recovering Cd(II) from the membranes. Ion-exchange capacities were constant over five cycles of binding-regeneration. PMID:27999394

  12. Chromatography and the hundred year mystery of inorganic ions at aqueous interfaces: adsorption of inorganic ions at the Porous Graphitic Carbon Aqueous Interface follows the Hofmeister series.

    Science.gov (United States)

    Cecchi, Teresa; Marcotulli, Federica

    2013-11-01

    Many physical phenomena are affected by the structure of water interfaces, yet it remains an active and controversial subject. A great deal of recent theoretical endeavour and computer simulations question the validity of the Onsager Samaras theory of the ion-free interface between an electrolyte solution and an hydrophobic surface. Experimental results play a crucial role in assessing the legitimacy of the theories. Experimental data are scarce, while simulation results suggest an increasing surface affinity of ions with increasing chaotropic character, in dramatic contradiction to the classical view. Chromatography is a powerful separative technique, but we originally used it as a tool to detect the adsorption of chloride electrolytes and sodium electrolytes, strongly expected to shun any dielectric boundary, onto an hydrophobic surface, and to rank ions according to their adsorbophilicities. Frontal analysis gave unequivocal experimental evidence to this unexpected phenomenon and it was used to quantify it. The infinite dilution equilibrium constants for adsorption of kosmotropes and chaotropes onto the interface were obtained and contrasted to the Jones-Dole B viscosity coefficients, that is a common quantifier of the Hofmeister effect. It is clear that (i) the more chaotropic the ion is, the more it contributes to the global adsorbophilicity of the electrolyte; (ii) the influence of the variable anion is more than twofold that of the variable cation, thereby confirming a robust observation in many other physical systems. Standard free energy of adsorption for each electrolyte was calculated and its reliability was commented upon. The central issue in this paper is the effective and ascertained adsorption of electrolytes onto an hydrophobic surface and the fact that the adsorbophilicity of an electrolyte may be inferred from its position in the Hofmeister series. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. Diisopropylethylamine/hexafluoroisopropanol-mediated ion-pairing ultra-high-performance liquid chromatography/mass spectrometry for phosphate and carboxylate metabolite analysis: utility for studying cellular metabolism.

    Science.gov (United States)

    Guo, Lili; Worth, Andrew J; Mesaros, Clementina; Snyder, Nathaniel W; Glickson, Jerry D; Blair, Ian A

    2016-08-30

    Mass spectrometric (MS) analysis of low molecular weight polar metabolites can be challenging because of poor chromatographic resolution of isomers and insufficient ionization efficiency. These metabolites include intermediates in key metabolic pathways, such as glycolysis, the pentose phosphate pathway, and the Krebs cycle. Therefore, sensitive, specific, and comprehensive quantitative analysis of these metabolites in biological fluids or cell culture models can provide insight into multiple disease states where perturbed metabolism plays a role. An ion-pairing reversed-phase ultra-high-performance liquid chromatography (IP-RP-UHPLC)/MS approach to separate and analyze biochemically relevant phosphate- and carboxylic acid-containing metabolites was developed. Diisopropylethylamine (DIPEA) was used as an IP reagent in combination with reversed-phase liquid chromatography (RP-LC) and a triple quadrupole mass spectrometer using selected reaction monitoring (SRM) and negative electrospray ionization (NESI). An additional reagent, hexafluoroisopropanol (HFIP), which has been previously used to improve sensitivity of nucleotide analysis by UHPLC/MS, was used to enhance sensitivity. HFIP versus acetic acid, when added with the IP base, increased the sensitivity of IP-RP-UHPLC/NESI-MS up to 10-fold for certain analytes including fructose-1,6-bisphosphate, phosphoenolpyruvate, and 6-phosphogluconate. It also improved the retention of the metabolites on a C18 reversed-phase column, and allowed the chromatographic separation of important isomeric metabolites. This methodology was amenable to quantification of key metabolites in cell culture experiments. The applicability of the method was demonstrated by monitoring the metabolic adaptations resulting from rapamycin treatment of DB-1 human melanoma cells. A rapid, sensitive, and specific IP-RP-UHPLC/NESI-MS method was used to quantify metabolites from several biochemical pathways. IP with DIPEA and HFIP increased the

  14. Integrated rapid resolution liquid chromatography-tandem mass spectrometric approach for screening and identification of metabolites of the potential anticancer agent 3,6,7-trimethoxyphenanthroindolizidine in rat urine.

    Science.gov (United States)

    Tian, Yaping; He, Jiuming; Zhang, Ruiping; Lv, Haining; Ma, Shuanggang; Chen, Yanhua; Yu, Shishan; Chen, Xiaoguang; Wu, Yan; He, Wenyi; Abliz, Zeper

    2012-06-20

    An integrated approach combining data acquisition using MS(E) and multi-period product ion scan (mpMS/MS), with high-resolution characteristic extracted ion chromatograms (hcXIC) as a data mining method, was developed for in vivo drug metabolites screening and identification. This approach is illustrated by analyzing metabolites of a potential anticancer agent, 3,6,7-trimethoxyphenanthroindolizidine (CAT) in rat urine based on rapid resolution liquid chromatography combined with tandem mass spectrometry (RRLC-MS/MS). Untargeted full-scan MS(E) enabled the high-throughput acquisition of potential metabolites, and targeted mpMS/MS contributed to the sensitivity and specificity of the acquisition of molecules of interest. The data processing method hcXIC, based on the structure of CAT, was shown to be highly effective for the metabolite discovery. Through the double-filtering effect of the characteristic ion and accurate mass, conventional extracted ion chromatograms that contained a substantial number of false-positive peaks were simplified into chromatograms essentially free of endogenous interferences. As a result, 21 metabolites were detected in rat urine after oral administration of CAT. Based on the characteristic fragmentation patterns of the phenanthroindolizidine alkaloid, the structures of 9 metabolites were identified. Furthermore, the interpretation of the MS/MS spectra of these metabolites enabled the determination of demethylation position as well as the differentiation between N-oxidized and hydroxylated metabolites. Copyright © 2012 Elsevier B.V. All rights reserved.

  15. Applying characteristic fragment filtering for rapid detection and identification of ingredients in rhubarb by HPLC coupled with linear ion trap-Orbitrap mass spectrometry.

    Science.gov (United States)

    Wang, Qing; Lu, Zhiwei; Zhang, Li; Zhang, Qingqing; Wang, Meiling; Zhao, Huizhen; Liu, Yuehong; Fu, Shuang; Huang, Zhenghai; Xie, Ziye; Yu, Honghong; Zhang, Zhixin; Gao, Xiaoyan

    2017-07-01

    Chemical characteristic fragment filtering in MSn chromatograms was proposed to detect and identify the components in rhubarb rapidly using high-performance liquid chromatography coupled with linear ion trap-Orbitrap mass spectrometry. Characteristic fragments consist of diagnostic ions and neutral loss fragments. Characteristic fragment filtering is a postacquisition data mining method for the targeted screening of groups with specific structures, including three steps: first, in order to comprehensively summarize characteristic fragments for global identification of the ingredients in rhubarb, representative authentic standards of dominant chemical categories contained in rhubarb were chosen, from which fragmentation rules and a characteristic fragments schedule were proposed; second, characteristic fragment filtering was used to rapidly recognize analogous skeletons; finally, combined with retention time, accurate mass, characteristic fragments, and previous literature, the structures of the filtered compounds were identified or tentatively characterized. As a result, a total of 271 compounds were detected and identified in rhubarb, including 34 anthraquinones, 83 anthrones, 46 tannins, 17 stilbenes, 24 phenylbutanones, 26 acylglucosides, 26 chromones, and 15 other compounds, 69 of which are potentially new compounds. The proposed characteristic fragment filtering strategy would be a reference for the large-scale detection and identification of the ingredients of herbal medicines. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Hyphenation of gas-diffusion separation and ion chromatography. Part 1: determination of free sulfite in wines.

    Science.gov (United States)

    Fäldt, S; Karlberg, B; Frenzel, W

    2001-10-01

    The hyphenation of gas-diffusion separation and ion chromatography (IC) is described as a convenient, reliable, robust, and economic method for in-line sample pre-treatment. The high selectivity associated with this method permits direct analysis of samples containing microparticulates, colloidal matter, and/or high molecular weight compounds. The determination of sulfite serves as a first example of its application. The method is based on the diffusional separation of SO2 following in-line oxidation with hydrogen peroxide to sulfate and final determination of the sulfate formed using IC. The influence of operational parameters has been thoroughly investigated and gas-diffusion cells of different geometries compared with respect to the gas-transfer rates obtained. Application to the analysis of wines demonstrates the utility of the method.

  17. Simultaneous determination of amino acids and carbohydrates in culture media of Clostridium thermocellum by valve-switching ion chromatography.

    Science.gov (United States)

    Fa, Yun; Yang, Haiyan; Ji, Chengshuai; Cui, He; Zhu, Xinshu; Du, Juan; Gao, Jun

    2013-10-10

    An improved method for the simultaneous determination of 20 amino acids and 7 carbohydrates using one-valve switching after injection, ion chromatography, and integrated pulsed amperometric detection is proposed. The resolution of the amino acids and carbohydrates in the cation trap column was investigated. In addition, parameters including flow liquid type, flow rate, concentration, and valve-switch timing were optimized. The method is time-saving, effective, and accurate for the simultaneous separation of amino acids and carbohydrates, with a mean correlation coefficient of >0.99 and repeatability of 0.5-4.6% for eight replicates. The method was successfully applied in the analysis of amino acids and carbohydrates in aseptic media and in extracellular culture media of three phenotypes of Clostridium thermocellum. Copyright © 2013 Elsevier B.V. All rights reserved.

  18. Detection of lysergic acid diethylamide (LSD) in urine by gas chromatography-ion trap tandem mass spectrometry.

    Science.gov (United States)

    Sklerov, J H; Kalasinsky, K S; Ehorn, C A

    1999-10-01

    A confirmatory method for the detection and quantitation of lysergic acid diethylamide (LSD) is presented. The method employs gas chromatography-tandem mass spectrometry (GC-MS-MS) using an internal ionization ion trap detector for sensitive MS-MS-in-time measurements of LSD extracted from urine. Following a single-step solid-phase extraction of 5 mL of urine, underivatized LSD can be measured with limits of quantitation and detection of 80 and 20 pg/mL, respectively. Temperature-programmed on-column injections of urine extracts were linear over the concentration range 20-2000 pg/mL (r2 = 0.999). Intraday and interday coefficients of variation were LSD-positive samples in this laboratory. Comparisons with alternate GC-MS methods and extraction procedures are discussed.

  19. Determination of gas phase triacetone triperoxide with aspiration ion mobility spectrometry and gas chromatography-mass spectrometry.

    Science.gov (United States)

    Räsänen, Riikka-Marjaana; Nousiainen, Marjaana; Peräkorpi, Kaleva; Sillanpää, Mika; Polari, Lauri; Anttalainen, Osmo; Utriainen, Mikko

    2008-08-08

    Aspiration ion mobility spectrometry (IMS) has been used for the first time to screen 3,3,6,6,9,9-hexamethyl-1,2,4,5,7,8-hexaoxacyclononane explosive, the most commonly known as triacetone triperoxide (TATP). Gaseous TATP was generated from synthesized solid compound, sublimed and directed to a portable chemical detection system comprised of an aspiration-type IMS detector and six semiconductor sensors. Different unknown TATP gas phase concentrations were produced and corresponding IMS and semiconductor responses were measured. The experimental concentrations were determined by gas chromatography-mass spectrometry (GC-MS). The results evidenced that the monitored compound in the gas phase was TATP. In addition, the determined TATP concentrations and corresponding IMS intensities showed that the IMS response values were proportional to the measured TATP concentrations.

  20. Rapid and sensitive hormonal profiling of complex plant samples by liquid chromatography coupled to electrospray ionization tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    Müller Maren

    2011-11-01

    Full Text Available Abstract Background Plant hormones play a pivotal role in several physiological processes during a plant's life cycle, from germination to senescence, and the determination of endogenous concentrations of hormones is essential to elucidate the role of a particular hormone in any physiological process. Availability of a sensitive and rapid method to quantify multiple classes of hormones simultaneously will greatly facilitate the investigation of signaling networks in controlling specific developmental pathways and physiological responses. Due to the presence of hormones at very low concentrations in plant tissues (10-9 M to 10-6 M and their different chemistries, the development of a high-throughput and comprehensive method for the determination of hormones is challenging. Results The present work reports a rapid, specific and sensitive method using ultrahigh-performance liquid chromatography coupled to electrospray ionization tandem spectrometry (UPLC/ESI-MS/MS to analyze quantitatively the major hormones found in plant tissues within six minutes, including auxins, cytokinins, gibberellins, abscisic acid, 1-amino-cyclopropane-1-carboxyic acid (the ethylene precursor, jasmonic acid and salicylic acid. Sample preparation, extraction procedures and UPLC-MS/MS conditions were optimized for the determination of all plant hormones and are summarized in a schematic extraction diagram for the analysis of small amounts of plant material without time-consuming additional steps such as purification, sample drying or re-suspension. Conclusions This new method is applicable to the analysis of dynamic changes in endogenous concentrations of hormones to study plant developmental processes or plant responses to biotic and abiotic stresses in complex tissues. An example is shown in which a hormone profiling is obtained from leaves of plants exposed to salt stress in the aromatic plant, Rosmarinus officinalis.

  1. Determination of the Alternaria mycotoxin tenuazonic acid in cereals by high-performance liquid chromatography-electrospray ionization ion-trap multistage mass spectrometry after derivatization with 2,4-dinitrophenylhydrazine.

    Science.gov (United States)

    Siegel, David; Rasenko, Tatjana; Koch, Matthias; Nehls, Irene

    2009-05-22

    Tenuazonic acid (TA) is a major Alternaria mycotoxin. In the present work a novel approach for the detection of TA in cereals by liquid chromatography-ion-trap multistage mass spectrometry after derivatization with 2,4-dinitrophenylhydrazine is described. The product of the derivatization reaction and its major MS(2) fragments were characterised by Fourier transform-ion cyclotron resonance tandem mass spectrometry. Without preconcentration, the established method features a limit of detection of 10 microg/kg using 2g of sample in a rapid workup procedure. Accuracy, precision and linearity were evaluated in the working range of 50-5000 microg/kg. TA was detected in 13 and quantified in 3 out of 27 cereal samples obtained from a local supermarket, the average content being 49 microg/kg (highest incidence: 851+/-41 microg/kg).

  2. Determination of antimony compounds in waters and juices using ion chromatography-inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Lin, Ya-An; Jiang, Shiuh-Jen; Sahayam, A C

    2017-09-01

    A method was developed by coupling ion chromatography (IC) and inductively coupled plasma mass spectrometry (ICP-MS) for the speciation of antimony. In this study, antimony species such as antimonite [Sb(III)], antimonate [Sb(V)] and trimethyl antimony(V) (TMeSb) were separated in less than 8min using anion exchange chromatography with a Hamilton PRP-X100 column as the stationary phase. Mobile phase A was 20mmolL(-1) ethylenediaminetetraacetic acid (EDTA), 2mmolL(-1) potassium hydrogen phthalate (KHP) in 1% v/v methanol (pH 5.5) and 20mmolL(-1) EDTA, 2mmolL(-1) KHP, 40mmolL(-1) (NH4)2CO3 in 1% v/v methanol (pH 9.0) formed mobile phase B. Detection limits and relative standard deviations (RSD) were 0.012-0.032ngmL(-1) and 2.2-2.8% respectively. This method was applied to bottled waters and fruit juices purchased in Kaohsiung, Taiwan. In water samples, Sb(V) was the major species where as in juices organometallic Sb species were also present. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Determination of short chain carboxylic acids in vegetable oils and fats using ion exclusion chromatography electrospray ionization mass spectrometry.

    Science.gov (United States)

    Viidanoja, Jyrki

    2015-02-27

    A new method for quantification of short chain C1-C6 carboxylic acids in vegetable oils and fats by employing Liquid Chromatography Mass Spectrometry (LC-MS) has been developed. The method requires minor sample preparation and applies non-conventional Electrospray Ionization (ESI) liquid phase chemistry. Samples are first dissolved in chloroform and then extracted using water that has been spiked with stable isotope labeled internal standards that are used for signal normalization and absolute quantification of selected acids. The analytes are separated using Ion Exclusion Chromatography (IEC) and detected with Electrospray Ionization Mass Spectrometry (ESI-MS) as deprotonated molecules. Prior to ionization the eluent that contains hydrochloric acid is modified post-column to ensure good ionization efficiency of the analytes. The averaged within run precision and between run precision were generally lower than 8%. The accuracy was between 85 and 115% for most of the analytes. The Lower Limit of Quantification (LLOQ) ranged from 0.006 to 7mg/kg. It is shown that this method offers good selectivity in cases where UV detection fails to produce reliable results. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. A solid phase extraction-ion chromatography with conductivity detection procedure for determining cationic surfactants in surface water samples.

    Science.gov (United States)

    Olkowska, Ewa; Polkowska, Żaneta; Namieśnik, Jacek

    2013-11-15

    A new analytical procedure for the simultaneous determination of individual cationic surfactants (alkyl benzyl dimethyl ammonium chlorides) in surface water samples has been developed. We describe this methodology for the first time: it involves the application of solid phase extraction (SPE-for sample preparation) coupled with ion chromatography-conductivity detection (IC-CD-for the final determination). Mean recoveries of analytes between 79% and 93%, and overall method quantification limits in the range from 0.0018 to 0.038 μg/mL for surface water and CRM samples were achieved. The methodology was applied to the determination of individual alkyl benzyl quaternary ammonium compounds in environmental samples (reservoir water) and enables their presence in such types of waters to be confirmed. In addition, it is a simpler, less time-consuming, labour-intensive, avoiding use of toxic chloroform and significantly less expensive methodology than previously described approaches (liquid-liquid extraction coupled with liquid chromatography-mass spectrometry). Copyright © 2013 Elsevier B.V. All rights reserved.

  5. Ligand-exchange chromatography of aromatic amines on resin-bound cobalt ion

    Energy Technology Data Exchange (ETDEWEB)

    Pehlivan, E.; Vural, U.S.; Ayar, A.; Yildiz, S. [Selcuk Univ., Konya (Turkey)

    1996-06-01

    The use of cobalt metal for the selective separation of aromatic amines is completed with a chemically bonded diamine and glyoxime functional groups onto Lycopodium clavatum. Oximes and amines are excellent complexing agents for transition metal ions. Cobalt(II) metal ions can easily be immobilized on bis-diaminoethyl-glyoximated sporopollenin (bDAEG-sporopollenin). The ligand-exchange behavior of modified Lycopodium clavatum with respect to aromatic amines was investigated. This will permit the evaluation of bDAEG-sporopollenin ligand exchangers for their utilization as sorbents in the recovery, pollution control, and elimination of amines from wastewater.

  6. Comparative study of glycated hemoglobin by ion exchange chromatography and affinity binding nycocard reader in type 2 diabetes mellitus.

    Science.gov (United States)

    Gautam, N; Dubey, R K; Jayan, A; Nepaune, Y; Padmavathi, P; Chaudhary, S; Jha, S K; Sinha, A K

    2014-12-01

    The aim of this study was to compare the level of glycated hemoglobin (HbA1c) in type 2 Diabetes Mellitus (DM) patients by two different methods namely Ion Exchange Chromatography and Affinity Binding Nycocard Reader. This is a cross-sectional study conducted on confirmed type 2 diabetes mellitus patients (n = 100) who visited Out Patients Department of the Universal College of Medical Sciences Teaching hospital, Bhairahawa, Nepal from November 2012 to March 2013. The diagnosis of diabetes mellitus was done on the basis of their fasting (164.46 ± 45.33 mg/dl) and random (187.93 ± 78.02 mg/dl) serum glucose level along with clinical history highly suggestive of type 2 DM. The HbA1c values of (7.8 ± 1.9%) and (8.0 ± 2.2%) were found in DM patients as estimated by those two different methods respectively. The highest frequency was observed in HbA1c > 8.0% indicating maximum cases were under very poor glycemic control. However, there were no significant differences observed in HbA1c value showing both methods are comparable in nature and can be used in lab for ease of estimation. The significant raised in HbA1c indicates complications associated with DM and monitoring of therapy become hard for those patients. Despite having standard reference method for HbA1c determination, the availability of report at the time of the patient visit can be made easy by using Nycocard Reader and Ion Exchange Chromatography techniques without any delay in communicating glycemic control, clinical decision-making and changes in treatment regimen.

  7. Alternative purification method for recombinant measles viral nucleoprotein expressed in insect cells by ion-exchange chromatography.

    Science.gov (United States)

    Lee, Han Saem; Kim, You-Jin; Yang, Jeongsun; Yoon, Hee Sook; Kim, Seung Tae; Kim, Kisoon

    2014-03-01

    Recombinant measles virus nucleoproteins (rMeV N) and fusion (F) proteins were characterized as major antigenic proteins expressed in insect cells mediated by recombinant baculoviruses (rBVs). Band intensities were analyzed by Western blotting to recognize IgG and IgM antibodies against the rMeV N and F proteins in human sera and cerebrospinal fluids (CSFs) from patients with measles infections. Positive results from the blots using the rMeV N were consistent with the results of enzyme-linked immunosorbent assays (ELISAs) in which whole viral proteins were used as antigens. Human sera and CSFs reacted more strongly with the rMeV N than with the rMeV F proteins prepared in an identical expression system. For efficient and reliable purification, ion-exchange chromatography using Source Q anion resin was applied, and high-purity rMeV N protein was harvested. To characterize the similarity with the native viral protein to purified N protein, structural mimicry of purified recombinant proteins with intact rMeV N was shown through transmission electron microscopy, and the truncation and the phosphorylation status of the expressed protein were analyzed. These results suggest that the rMeV N purified by ion-exchange chromatography has features similar to those of naïve N including a self-assembled structure, phosphorylation and antigenic function. Thus, these expression and purification methods can be applied to the large-scale production of the rMeV N, which is essential for the development of new diagnostic tools and vaccines for acute and chronic MeV infections. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Rapid comparison of a candidate biosimilar to an innovator monoclonal antibody with advanced liquid chromatography and mass spectrometry technologies.

    Science.gov (United States)

    Xie, Hongwei; Chakraborty, Asish; Ahn, Joomi; Yu, Ying Qing; Dakshinamoorthy, Deepalakshmi P; Gilar, Martin; Chen, Weibin; Skilton, St John; Mazzeo, Jeffery R

    2010-01-01

    This study shows that state-of-the-art liquid chromatography (LC) and mass spectrometry (MS) can be used for rapid verification of identity and characterization of sequence variants and posttranslational modifications (PTMs) for antibody products. A candidate biosimilar IgG1 monoclonal antibody (mAb) was compared in detail to a commercially available innovator product. Intact protein mass, primary sequence, PTMs, and the micro-differences between the two mAbs were identified and quantified simultaneously. Although very similar in terms of sequences and modifications, a mass difference observed by LC-MS intact mass measurements indicated that they were not identical. Peptide mapping, performed with data independent acquisition LC-MS using an alternating low and elevated collision energy scan mode (LC-MS(E)), located the mass difference between the biosimilar and the innovator to a two amino acid residue variance in the heavy chain sequences. The peptide mapping technique was also used to comprehensively catalogue and compare the differences in PTMs of the biosimilar and innovator mAbs. Comprehensive glycosylation profiling confirmed that the proportion of individual glycans was different between the biosimilar and the innovator, although the number and identity of glycans were the same. These results demonstrate that the combination of accurate intact mass measurement, released glycan profiling, and LC-MS(E) peptide mapping provides a set of routine tools that can be used to comprehensively compare a candidate biosimilar and an innovator mAb.

  9. Rapid Isolation and Determination of Flavones in Biological Samples Using Zinc Complexation Coupled with High-Performance Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    Chenghe Sun

    2016-08-01

    Full Text Available Chlorophyll-type contaminants are commonly encountered in the isolation and determination of flavones of plant aerial plant parts. Heme is also a difficult background substance in whole blood analysis. Both chlorophyll and heme are porphyrin type compounds. In this study, a rapid method for isolating flavones with 5-hydroxyl or ortho-hydroxyl groups from biological samples was developed based on the different solubilities of porphyrin-metal and flavone-metal complexes. It is important that other background substances, e.g., proteins and lipids, are also removed from flavones without an additional processing. The recoveries of scutellarin, baicalin, baicalein, wogonoside and wogonin, which are the primary constituents of Scutellaria baicalensis (skullcaps were 99.65% ± 1.02%, 98.98% ± 0.73%, 99.65% ± 0.03%, 97.59% ± 0.09% and 95.19% ± 0.47%, respectively. As a sample pretreatment procedure, this method was coupled to high-performance liquid chromatography (HPLC with good separation, sensitivity and linearity and was applied to determine the flavone content in different aerial parts of S. baicalensis and in dried blood spot samples.

  10. Magnetic covalent triazine framework for rapid extraction of phthalate esters in plastic packaging materials followed by gas chromatography-flame ionization detection.

    Science.gov (United States)

    Yan, Zijun; He, Man; Chen, Beibei; Gui, Bo; Wang, Cheng; Hu, Bin

    2017-11-24

    Covalent triazine frameworks (CTFs), featuring with high surface area, good thermal, chemical and mechanical stability, are good adsorbents in sample pretreatment. Herein, magnetic CTFs/Ni composite was prepared by in situ reduction of nickel ions on CTFs matrix with a solvothermal method. The prepared CTFs/Ni composite exhibited good preparation reproducibility, high chemical stability, and high extraction efficiency for targeted phthalate esters (PAEs) due to π-π interaction and hydrophobic effect. The porous structure of CTFs/Ni composite benefited the fast transfer of target PAEs from aqueous solution to the adsorbents, and the integrated magnetism contributed to the rapid separation of adsorbents from sample and elution solution. Based on it, a novel method of magnetic solid phase extraction (MSPE) combined with gas chromatography-flame ionization detector (GC-FID) was developed for the analysis of PAEs including dimethyl phthalate (DMP), diethyl phthalate (DEP), di-n-butyl phthalate (DBP), benzyl butyl phthalate (BBP), di-2-ethylhexl phthalate (DEHP), and di-n-octyl phthalate (DNOP) in plastic packaging materials. Under the optimal experimental conditions, the limits of detection (LODs, S/N=3) for six PAEs were found to be in the range of 0.024-0.085mg/kg. The linear range was 0.32-16mg/kg for DMP, DEP, 0.08-80mg/kg for DBP, 0.16-32mg/kg for BBP, DEHP, and 0.32-32mg/kg for DNOP, respectively. The enrichment factors ranged from 59 to 88-fold (theoretical enrichment factor was 133-fold). The proposed method was successfully applied to the analysis of PAEs in various plastic packaging materials with recoveries in the range of 70.6-119% for the spiked samples. This method is characterized with short operation time, high sensitivity, low consumption of harmful organic solvents and can be extended to the analysis of other trace aromatic compounds. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Speciation of aluminum in rainwater using a fluoride ion-selective electrode and ion-exchange chromatography with fluorometric detection of the aluminum-lumogallion complex.

    Science.gov (United States)

    Hara, H; Kobayashi, H; Maeda, M; Ueno, A; Kobayashi, Y

    2001-11-15

    Soluble aluminum in rainwater was separated into three categories: free aluminum (Al3+), fluoride complexes (sum of AlF2+ and AlF2+), and other forms of aluminum. The free form of the aluminum ion (Al3+) was directly obtained from the separation data of aluminum species according to their charge using gradient elution cation-exchange chromatography. The aluminum fluoride complexes were estimated by combining the data of the free and total fluoride determined using a fluoride ion-selective electrode, with the assumption that 2+ charged aluminum species consisted only of AlF2+. The rest of the aluminum species had a 1+, neutral, or negative charge and mainly consisted of organic complexes. The origin of the organically bound aluminum is discussed. The concentration range of the total dissolved fluoride and aluminum in the rainwater samples was usually in the micromolar to submicromolar range, and the ratio of [T-F]/[T-Al] was found to be between 1 and 4. The speciation of dissolved aluminum into three categories was carried out on the basis of data of 15 rainwater samples collected in the city of Otsu.

  12. Comprehensive Analysis of Umami Compounds by Ion-Pair Liquid Chromatography Coupled to Mass Spectrometry

    NARCIS (Netherlands)

    Coulier, L.; Bas, R.; Hekman, M.; Werff, B.J.C. van der; Burgering, M.; Thissen, U.

    2011-01-01

    An ion-pair LC-ESI-MS method was developed capable of analyzing various reported umami or umami-enhancing compounds, including glutamic acid and 5'-ribonucleotides. The method was validated using tomato and potato samples and showed overall good analytical performance with respect to selectivity,

  13. Determination of aminophenols and phenol in hair colorants by ultrasound-assisted solid-phase dispersion extraction coupled with ion chromatography.

    Science.gov (United States)

    Zhong, Zhixiong; Li, Gongke; Wu, Rong; Zhu, Binghui; Luo, Zhibin

    2014-08-01

    A simple and reliable ultrasound-assisted solid-phase dispersion extraction coupled with ion chromatography was developed for the determination of aminophenols and phenol. The highly viscous hair colorant was dispersed in solvents using anhydrous sodium sulfite having dual functions of dispersant and antioxidant. The use of anhydrous sodium sulfite did not change the sample volume because it could completely dissolve in solution after matrix dispersion. The extraction and cleanup were combined in one single step for simplifying operation. The extraction process could be rapidly accomplished within 9 min with high sample throughput under the synergistic effects of vibration, ultrasound, and heating. Satisfactory linearity was observed with correlation coefficients higher than 0.9992, and the limits of detection varied from 0.02 to 0.09 mg/L. The applicability of the proposed method was demonstrated by measuring the concentrations of aminophenols and phenol in 32 different commercial hair color products. The recoveries ranged from 86.4-101.2% with the relative standard deviations in the range of 0.52-4.3%. The method offers an attractive alternative for the analysis of trace phenols in complex matrices. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Ultrasound-assisted low-density solvent dispersive liquid-liquid extraction for the determination of alkanolamines and alkylamines in cosmetics with ion chromatography.

    Science.gov (United States)

    Zhong, Zhixiong; Li, Gongke; Zhong, Xiuhua; Luo, Zhibin; Zhu, Binghui

    2013-10-15

    A new one-step sample preparation technique termed ultrasound-assisted low-density solvent dispersive liquid-liquid extraction (UA-LDS-DLLE) coupled with ion chromatography (IC) was developed for the determination of three alkanolamines and two alkylamines in complex samples. Sample matrices were rapidly dissolved and dispersed to form cloudy solutions by using two solvents, where target analytes were transferred into acid solutions, while liposoluble substances were dissolved in cyclohexane. The obtained extracts could be used directly for injection analysis without any additional purification because the potential matrix interferences had been effectively eliminated in extraction process. The extraction efficiency could be markedly enhanced and the extraction could be quickly accomplished within 13 min under the synergistic effects of ultrasound radiation, vibration and heating. Various parameters influencing extraction efficiency were evaluated using orthogonal array experimental design. The extraction performance of the approach was demonstrated for the determination of target analytes in 15 commercial cosmetics covering very different matrices. Linearity ranges of 0.3-50 mg L(-1) and limits of detection varying from 0.072 to 0.12 mg L(-1) were achieved. The recoveries ranged from 86.9-108.5% with the relative standard deviations (RSDs) of 1.2-6.2%. The method was proved to be a simple and effective extraction technique that provided an attractive alternative to the analysis of trace amounts of target analytes in large numbers of cosmetics. Copyright © 2013. Published by Elsevier B.V.

  15. Multiresidue Screening of Veterinary Drugs in Meat, Milk, Egg, and Fish Using Liquid Chromatography Coupled with Ion Trap Time-of-Flight Mass Spectrometry.

    Science.gov (United States)

    Kang, JeongWoo; Park, Su-Jeong; Park, Hae-Chul; Hossain, Md Akil; Kim, Myeong-Ae; Son, Seong-Wan; Lim, Chae-Mi; Kim, Tae-Wan; Cho, Byung-Hoon

    2017-06-01

    New approaches to veterinary drug screening based on liquid chromatography-mass spectrometry (LC-MS/MS) and time-of-flight mass spectrometry (ToF/MS) are rapid and have high selectivity and sensitivity. In this study, we developed a multiresidue method for screening over 100 veterinary drug residues using ion trap (IT)-ToF/MS. The screened compounds comprised major drug classes used in veterinary practice, representing the following: amphenicols, anthelmintics, benzimidazoles, β-lactams, coccidiostats, ionophores, macrolides, non-steroidal anti-inflammatory drugs, quinolones, sulfonamides, tetracyclines, and tranquilizers. The method was developed based on chromatographic retention time, specific accurate mass, isotope distribution, and fragment data. Each compound was validated at three levels, and the mass accuracy, accuracy, and repeatability were calculated. All parameters showed acceptable values and conformed to the Commission Decision 2002/657/EC criteria. This screening method can simultaneously analyze over 100 veterinary drugs in meat, milk, eggs, and fish in a single analytical run.

  16. Application of linear pH gradients for the modeling of ion exchange chromatography: Separation of monoclonal antibody monomer from aggregates.

    Science.gov (United States)

    Kluters, Simon; Wittkopp, Felix; Jöhnck, Matthias; Frech, Christian

    2016-02-01

    The mobile phase pH is a key parameter of every ion exchange chromatography process. However, mechanistic insights into the pH influence on the ion exchange chromatography equilibrium are rare. This work describes a mechanistic model capturing salt and pH influence in ion exchange chromatography. The pH dependence of the characteristic protein charge and the equilibrium constant is introduced to the steric mass action model based on a protein net charge model considering the number of amino acids interacting with the stationary phase. This allows the description of the adsorption equilibrium of the chromatographed proteins as a function of pH. The model parameters were determined for a monoclonal antibody monomer, dimer, and a higher aggregated species based on a manageable set of pH gradient experiments. Without further modification of the model parameters the transfer to salt gradient elution at fixed pH is demonstrated. A lumped rate model was used to predict the separation of the monoclonal antibody monomer/aggregate mixture in pH gradient elution and for a pH step elution procedure-also at increased protein loadings up to 48 g/L packed resin. The presented model combines both salt and pH influence and may be useful for the development and deeper understanding of an ion exchange chromatography separation. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Speciation of arsenic(III)/arsenic(V) and selenium(IV)/ selenium(VI) using coupled ion chromatography - hydride generation atomic absorption spectrometry

    Science.gov (United States)

    Simple analytical methods have been developed to speciate inorganic arsenic and selenium in the ppb range using coupled ion chromatography-hydride generation atomic absorption spectrometry. Because of the differences in toxicity and adsorption behavior, determinations of the redox states arsenite A...

  18. Screening and confirmation criteria for hormone residue analysis using liquid chromatography accurate mass time-of-flight, Fourier transform ion cyclotron resonance and orbitrap mass spectrometry techniques

    NARCIS (Netherlands)

    Nielen, M.W.F.; Engelen, M.C. van; Zuiderent, R.; Ramaker, R.

    2007-01-01

    An emerging trend is recognised in hormone and veterinary drug residue analysis from liquid chromatography tandem mass spectrometry (LC/MS/MS) based screening and confirmation towards accurate mass alternatives such as LC coupled with time-of-flight (TOF), Fourier transform ion cyclotron resonance

  19. Sequence-dependent separation of trinucleotides by ion-interaction reversed-phase liquid chromatography A structure-retention study assisted by soft-modelling and molecular dynamics

    Czech Academy of Sciences Publication Activity Database

    Mikulášek, K.; Jaroň, Kamil S.; Kulhánek, P.; Bittová, M.; Havliš, J.

    2016-01-01

    Roč. 1469, October (2016), s. 88-95 ISSN 0021-9673 Institutional support: RVO:68081766 Keywords : Sequence-dependent separation * Ion-interaction reversed-phase liquid chromatography * Trinucleotides * Oligonucleotide sequence isomers * QSRR * Molecular dynamics Subject RIV: CE - Biochemistry Impact factor: 3.981, year: 2016

  20. Rapid analysis of the interactions between drugs and human serum albumin (HSA) using high-performance affinity chromatography (HPAC)

    OpenAIRE

    Kim, Hee Seung; Wainer, Irving W.

    2008-01-01

    This study used a combination of zonal elution and frontal affinity chromatography on immobilized human serum albumin (HSA) high-performance affinity chromatography (HPAC) column to examine the association constants of various compounds that have been studied by equilibrium dialysis or ultra filtration. A standard plot was generated from retention factors of reference compounds using zonal elution chromatography against association constants of reference compounds using frontal affinity chrom...

  1. Rapid simultaneous determination of organophosphorus pesticides in human serum and urine by liquid chromatography-mass spectrometry

    Directory of Open Access Journals (Sweden)

    Zlatković Milica

    2010-01-01

    Full Text Available Background/Aim. Analysis of organophosphosphorus compounds and their metabolites in a biological material includes the use of numerous methods, covering both preparation of samples for analysis and their identification that is considered to be very complex. Low concentrations monitoring requires implementation of highly sensitive analytical techniques. The aim of this study was to develop and validate an original and sensitive method for the detection and quantitation of organophosphorus pesticides (dimethoate, diazinon, malathion and malaoxon in human biological matrices (serum, urine. Methods. This method was based on a solid-phase extraction procedure, a chromatographic separation using an ACQUITY UPLC ® HSST3 column and mass spectrometric detection in the positve ion mode. Mobile phase: was consited of Solvent A (5 mM ammonium formate pH 3.0 and Solvent B (0.1% acetic formate in methanol, in a linear gradient (constant flow-rate 0.3 mL/min. Results. The standard curve was linear in the range of 0.05-5.00 mg/L for malathion and malaoxon, 0.10-5.00 mg/L for dimethoate and 0.05-2.50 mg/L for diazinon. The correlation coefficient was r ≥ 0.99. Extraction recoveries were satisfactory and ranged between 90-99%. The limits of detection (LOD was between 0.007- 0.07 mg/L and the limits of quantitation (LOQ ranged between 0.022-0.085 mg/L. Intra- and interassay precision and accuracy were satisfactory for all of the pesticides analyzed. Conclusion. The method of liquid chromatography - mass spectrometry is simple, accurate, and useful for the determination of organophosphorus pesticides in both clinical and forensic toxicology.

  2. Rapid identification of siderophores by combined thin-layer chromatography/matrix-assisted laser desorption/ionization mass spectrometry.

    Science.gov (United States)

    Hayen, Heiko; Volmer, Dietrich A

    2005-01-01

    The investigation of a combined thin-layer chromatography/matrix-assisted laser desorption/ionization mass spectrometry (TLC/MALDI-MS) method for the analysis of siderophores from microbial samples is described. The investigated siderophores were enterobactin, ferrioxamine B, ferrichrome, ferrirhodin, rhodotorulic acid and coprogen. Solid-phase extraction was employed to recover the siderophores from the microbial samples. After visualization of the spots via spraying with ferric chloride or chrome azurol sulfonate assay solution, the MALDI matrix was applied to the gel surface. Several TLC/MALDI experimental parameters were optimized, such as type and concentration of MALDI matrix, as well as the type and composition of solvent to facilitate analyte transport from the inside of the TLC gel to the surface. The impact of these parameters on sensitivity, precision and ion formation of the various siderophores was studied. The detection limits for the investigated siderophores were in the range 1-4 pmol. These values were about 4-24 times higher than the detection limits obtained directly from stainless steel MALDI targets. The differences were most likely due to incomplete transport of the 'trapped' analyte molecules from the deeper layers of the TLC gel to the surface and into the matrix layer. In addition, chromatographic band broadening spread the analyte further in TLC as compared with the steel plates, resulting in less analyte per surface area. The identification of the siderophores was aided by concurrently applying a Ga(III) nitrate solution to the TLC plate during the visualization step. The resulting formation of Ga(III) complexes lead to distinctive (69)Ga/(71)Ga isotope patterns in the mass spectra. The versatility of the TLC/MALDI-MS assay was demonstrated by using it to analyze siderophores in a Pseudomonas aeruginosa sample. An iron-binding compound was identified in the sample, namely pyochelin (2-(2-o-hydroxyphenyl-2-thiazolin-4-yl)-3

  3. Detection of trace fluoride in serum and urine by online membrane-based distillation coupled with ion chromatography.

    Science.gov (United States)

    Lou, Chaoyan; Guo, Dandan; Wang, Nani; Wu, Shuchao; Zhang, Peimin; Zhu, Yan

    2017-06-02

    An online membrane-based distillation (MBD) coupled with ion chromatography (IC) method was proposed for automatic detection of trace fluoride (F - ) in serum and urine samples. The system consisted of a sample vessel, a lab-made membrane module and an ion chromatograph. Hydrophobic polytetrafluoroethylene (PTFE) hollow fiber membrane was used in MBD which was directly performed in serum and urine samples to eliminate the matrix interferences and enrich fluoride, while enabling automation. The determination of fluoride in biological samples was carried out by IC with suppressed conductometric detection. The proposed method feasibly determined trace fluoride in serum and urine matrices with the optimized parameters, such as acid concentration, distillation temperature, and distillation time, etc. Fluoride exhibited satisfactory linearity in the range of 0.01-5.0mg/L with a correlation coefficient of 0.9992. The limit of detection (LOD, S/N=3) and limit of quantification (LOQ, S/N=10) were 0.78μg/L and 2.61μg/L, respectively. The relative standard deviations of peak area and peak height were all less than 5.15%. The developed method was validated for the determination of fluoride in serum and urine with good spiked recoveries ranging between 97.1-101.9%. This method also can be proposed as a suitable alternative for the analysis of fluoride in other complex biological samples. Copyright © 2017. Published by Elsevier B.V.

  4. Separation of polythionates and the gold thiosulfate complex in gold thiosulfate leach solutions by ion-interaction chromatography.

    Science.gov (United States)

    O'Reilly, John W; Shaw, Matthew J; Dicinoski, Greg W; Grosse, Andrew C; Miura, Yasuyuki; Haddad, Paul R

    2002-07-01

    A method for the separation of the polythionates (SxO6(2-), x = 3-5) in gold thiosulfate leach solutions using ion-interaction chromatography with conductivity and ultraviolet (UV) detection is described. Polythionates were eluted within 18 min using an eluent comprising an acetonitrile step gradient at 0.0 min from 15% v/v to 28% v/v, 3 mM TBAOH, and 2.5 mM sodium carbonate, operated using a Dionex NS1-5 micron column with guard. The developed method was capable of separating the gold thiosulfate complex ion in standard solutions, but quantification of this species in realistic leach solutions proved impractical due to a self-elution effect that caused the gold peak to be eluted as a broad band. Detection limits for polythionates using a 10 microL injection volume ranged between 1-6 mg L(-1) (5-23 microM) for conductivity and 0.8-13 mg L(-1) (4-68 microM) for UV detection, based on a signal-to-noise ratio of 2. Calibration was linear over the ranges 5-2000, 10-2000 and 25-2500 mg L(-1) for trithionate, tetrathionate and pentathionate, respectively. The technique was applied successfully to leach liquors containing 0.5 M ammonium thiosulfate, 2 M ammonia, 0.05 M copper sulfate and 20 % m/v gold ore.

  5. Determination of selenite and selenate in human urine by ion chromatography and inductively coupled plasma mass spectrometry

    DEFF Research Database (Denmark)

    Gammelgaard, Bente; Jons, O.

    2000-01-01

    The selenium species selenite, selenate and selenomethionine were separated in aqueous solution by ion chromatography. The separation was performed on an IonPac AG11 in series with an AS11 anion exchange column by elution with 25 mM sodium hydroxide in 2% methanol. The Se-78 and Se-82 isotopes were...... monitored in the inductively coupled plasma mass spectrometry (ICP-MS) detector. When the chromatographic system was applied to analysis of urine samples diluted 1 + 1, the selenomethionine signal appeared in the front together with other unresolved selenium species, while the selenite and selenate signals...... were well separated. Calibration curves obtained after spiking a urine pool with standards in the range 2-50 mu g Se l(-1) were linear for selenite as well as selenate. The precision at the 10 mu g l(-1) level was better than 1%. The limits of detection were 0.4 and 0.8 mu g l(-1) for selenite...

  6. A comprehensive method for lipid profiling by liquid chromatography-ion cyclotron resonance mass spectrometry[S

    Science.gov (United States)

    Fauland, Alexander; Köfeler, Harald; Trötzmüller, Martin; Knopf, Astrid; Hartler, Jürgen; Eberl, Anita; Chitraju, Chandramohan; Lankmayr, Ernst; Spener, Friedrich

    2011-01-01

    This work aims to combine chromatographic retention, high mass resolution and accuracy, MS/MS spectra, and a package for automated identification and quantitation of lipid species in one platform for lipidomic analysis. The instrumental setup elaborated comprises reversed-phase HPLC coupled to a Fourier transform ion cyclotron resonance mass spectrometer (LTQ-FT), and Lipid Data Analyzer (LDA) software. Data analysis for lipid species quantification in this platform is based on retention time, mass resolution of 200,000, and mass accuracy below 2 ppm. In addition, automatically generated MS/MS spectra provide structural information at molecular level. This LC/MS technology allows analyzing complex biological samples in a quantitative manner as shown here paradigmatically for murine lipid droplets having a huge surplus of triacylglycerol species. Chromatographic preseparation of the bulk lipid class alleviates the problem of ion suppression of lipid species from other classes. Extension of 1D to 2D chromatography is possible, yet time consuming. The platform affords unambiguous detection of lipid species as low as 0.1‰ within major lipid classes. Taken together, a novel lipidomic LC/MS platform based on chromatographic retention, high mass resolution and accuracy, MS/MS analysis, and quantitation software enables analysis of complex samples as demonstrated for lipid droplets. PMID:21960706

  7. Simultaneous characterization of pyrrolizidine alkaloids and N-oxides in Gynura segetum by liquid chromatography/ion trap mass spectrometry.

    Science.gov (United States)

    Qi, Xueyong; Wu, Bin; Cheng, Yiyu; Qu, Haibin

    2009-01-01

    Gynura segetum (Lour.) Merr. (Jusanqi) is a traditional herbal product used for hemostasis and detumescence in Chinese folk medicine. However, its hepatic toxicity should not be ignored. In this study, pyrrolizidine alkaloids (PAs) and their corresponding N-oxides (PANOs) were extracted from the whole plant of G. segetum and analyzed by high-performance liquid chromatography coupled to ion trap mass spectrometry (ITMS). Identification of eluted peaks as PANOs was indicated by virtue of their MS and MS(n) analysis, in addition to the [M+H](+) adduct ion, characteristically showed a significant (usually 100% abundance) dimer adduct [2M+H](+) that is not observed in the MS of the parent PAs. A total of 20 compounds were identified or tentatively characterized based on their mass spectra and possible biosynthetic pathways, of which three PAs and one PANO, namely seneciphylline, senecionine, seneciphylline and seneciphyllinine N-oxide, were unequivocally characterized, while other PAs and PANOs were tentatively assigned. Sixteen constituents were reported for the first time from G. segetum and tetrahydrosenecionine has not been previously reported as a natural product. Our results are the first comprehensive analysis of PAs and PANOs in G. segetum constituents and will be helpful for the quality control of the herb of G. segetum and its related preparations. Copyright (c) 2008 John Wiley & Sons, Ltd.

  8. Application of ion mobility spectrometry to the rapid screening of methamphetamine incorporated in hair.

    Science.gov (United States)

    Miki, A; Keller, T; Regenscheit, P; Dirnhofer, R; Tatsuno, M; Katagi, M; Nishikawa, M; Tsuchihashi, H

    1997-05-09

    Using ion mobility spectrometry (IMS), a simple, sensitive and rapid screening for methamphetamine (MA) incorporated in user's hair has been developed. To completely unbind MA from hair matrix and to achieve its effective vaporization for the IMS detection, the hair sample was digested in 5 M NaOH (methanol-water, 4:1, v/v) solution prior to IMS measurement. MA in hair was semi-quantitatively detected by monitoring the digested hair sample employing dibenzylamine (DBA) as internal standard. The minimum amount of hair sample required was 2 mg and its digested sample was ample for four IMS measurements. The detection limit of MA in hair was 0.5 ng mg(-1). This proposed method was applicable to the semi-quantitative detection of MA in users' hair samples, and to the sectional analysis for MA in a limited amount of user's hair. The IMS results obtained were in good agreement with their GC-MS determination.

  9. Design and performance evaluation of a microfluidic ion-suppression module for anion-exchange chromatography.

    Science.gov (United States)

    Wouters, Sam; Wouters, Bert; Jespers, Sander; Desmet, Gert; Eghbali, Hamed; Bruggink, Cees; Eeltink, Sebastiaan

    2014-08-15

    A microfluidic membrane suppressor has been constructed to suppress ions of alkaline mobile-phases via an acid-base reaction across a sulfonated poly(tetrafluoroethylene)-based membrane and was evaluated for anion-exchange separations using conductivity detection. The membrane was clamped between two chip substrates, accommodating rectangular microchannels for the eluent and regenerant flow, respectively. Additionally, a clamp-on chip holder has been constructed which allows the alignment and stacking of different chip modules. The response and efficacy of the microfluidic chip suppressor was assessed for a wide range of eluent (KOH) concentrations, using 127 and 183μm thick membranes, while optimizing the flow rate and concentration of the regenerant solution (H2SO4). The optimal operating eluent flow rate was determined at 5μL/min, corresponding to the optimal van-Deemter flow velocity of commercially-available column technology, i.e. a 0.4mm i.d.×250mm long column packed with 7.5μm anion-exchange particles. When equilibrated at 10mM KOH, a 99% decrease in conductivity signal could be obtained within 5min when applying 10mM H2SO4 regenerant at 75μL/min. A background signal as low as 1.2μS/cm was obtained, which equals the performance of a commercially-available electrolytic hollow-fiber suppressor. When increasing the temperature of the membrane suppressor from 15 to 20°C, ion suppression was significantly improved allowing the application of 75mM KOH. The applicability of the chip suppressor has been demonstrated with an isocratic baseline separation of a mixture of seven inorganic ions, yielding plate numbers between 5300 and 10,600 and with a gradient separation of a complex ion mixture. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Bromate peak distortion in ion chromatography in samples containing high chloride concentrations.

    Science.gov (United States)

    Pappoe, Michael K; Naeeni, Mohammad Hosein; Lucy, Charles A

    2016-04-29

    In this study, the effect of column overload of the matrix ion, chloride, on the elution peak profiles of trace bromate is investigated. The resultant peak profiles of chloride and bromate are explained on the basis of competitive Langmuir isotherms. The Thermo IonPac AS9-HC, AS19 and AS23 columns are recommended by the manufacturer for bromate (a carcinogen) analysis. Under trace conditions, these columns provide baseline resolution of bromate from matrix ions such as chloride (Rs=2.9, 3.3 and 3.2, respectively for the three columns). Injection of 10-300 mM chloride with both hydroxide and carbonate eluents resulted in overload on these columns. On the basis of competitive Langmuir isotherms, a deficiency in the local concentration of the more retained eluent in addition to analyte overload leads to fronting of the overloaded analyte peak. The peak asymmetries (B/A10%) for chloride changed from 1.0 (Gaussian) under trace conditions to 0.7 (fronting) at 300 mM Cl(-) for IonPac AS9-HC, 0.9-0.6 for AS19 and 0.8-0.5, for AS23, respectively. The 10mM bromate peak is initially near Gaussian (B/A10%=0.9) but becomes increasingly distorted and pulled back into the chloride peak as the concentration of chloride increased. Increasing the eluent strength reduced the pull-back effect on bromate and fronting in chloride in all cases. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. New block-grafted anion exchanger for environmental water analysis by ion chromatography.

    Science.gov (United States)

    Jackson, P E; Thomas, D H; Donovan, B; Pohl, C A; Kiser, R E

    2001-06-22

    The IonPac AS14A is a recently developed stationary phase that was produced using a new block-grafting technique, which enables the preparation of high-water-content anion exchangers with excellent peak shape and good chromatographic efficiency. The performance of this column for the analysis of inorganic anions was compared to that obtained using an IonPac AS4A column, which is specified in US Environmental Protection Agency Method 300.0, in addition to another commonly used alternative: the AS14 column. The AS14A column is available in two different formats: 250x4 mm I.D. (7.0 microm diameter particle) and 150x3 mm I.D. (5.5 microm diameter particle). The IonPac AS14A (in 4 mm I.D. format) was found to provide similar performance to the AS14 column with increased peak efficiency and better pH stability and is a suitable alternative for the analysis of anions in moderate- to high-ionic-strength samples. The IonPac AS14A (in 3 mm I.D. format) provides comparable run times to the AS4A column with better overall peak selectivity and improved fluoride resolution, hence this column would be a suitable column to substitute in place of either the AS4A or AS14 columns for the analysis of inorganic anions in low- to moderate-ionic-strength environmental waters. The AS14A column used with an Atlas electrolytic suppressor provides equivalent method detection limits to those obtained when using a micromembrane suppressor but with the operational convenience of a self-regenerating suppressor.

  12. Predicting protein retention time in ion-exchange chromatography based on three-dimensional protein characterization.

    Science.gov (United States)

    Xu, Li; Glatz, Charles E

    2009-01-09

    The isoelectric point (pI), molecular weight (M(W)) and aqueous two-phase partitioning coefficients of a set of model proteins were related to retention time in cation-exchange chromatography using partial least squares regression. A three-dimensional method which combined hydrophobic partitioning and two-dimensional electrophoresis was used to determine those three properties for a mixture of proteins. The regression models fit well (R(2)=0.913 and 0.873 for two resin types) considering the limited property basis, and were able to predict results for a small test set of proteins. The models showed that greater size and charge increased retention time, while the net influence of hydrophobicity depended on the base matrix type. This establishes the potential for the intended application to complex mixtures of host cell proteins.

  13. Alternative extraction of alkaloid anticarcinogens from Brazilian "vinca rosea" using Ion exchange chromatography

    Directory of Open Access Journals (Sweden)

    Sérgio Freire de Carvalhaes

    Full Text Available Extracts in ethanol and ethanol-ammonia of dried leaves from Catharanthus roseus, gathered at Rio de Janeiro state, were adsorbed in a strongly acidic cation exchange resin with sulfonic acid group, using the finite bath method, resulting in an alkaloid retained fraction and an acidic and neutral unretained fraction. High Performance Liquid Chromatography showed the isolation of the alkaloid fraction to be highly selective and with good performance, with an absence of alkaloids in the unretained fraction, while the retained fraction presented 1,54-6,35 mg/g of vindoline and 0,12-0,91 mg/g of vinblastine, common for an alkaloid-rich concentrate, usually obtained by classic extraction with several steps using solvents.

  14. Ion-Exchange Membrane Chromatography as an Alternative Method of Separation of Potato y Virus

    Directory of Open Access Journals (Sweden)

    Treder Krzysztof

    2015-12-01

    Full Text Available Procedures of separation of virus particles from a plant material are multistage. Furthermore often they are difficult in terms of methodology and require use of expensive, highly specialist equipment and yield of separation is often low. The antigen obtained is often degraded and contains admixtures of other proteins. Therefore, generation of high quality and specificity antibodies based on such antigen is very difficult and quality of the antibodies has impact on reliability, sensitivity and unambiguity of results of immunodiagnostic tests (e.g. ELISA that are currently conventionally used to detect vegetable viruses. In this study three conventionally-performed methods of separation of potato virus Y (PVY were compared and a method of separation based on membrane chromatography, as an alternative separation technique, has been presented. It has been demonstrated that in proper process conditions good quality virus preparation can be obtained.

  15. Rapid quantification of metabolic intermediates in blood by liquid chromatography-tandem mass spectrometry to investigate congenital lactic acidosis.

    Science.gov (United States)

    Peng, Minzhi; Cai, Yanna; Fang, Xiefan; Liu, Li

    2016-10-26

    A novel liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been established to quantify metabolic intermediates, including lactate (Lac), pyruvate (Pyr), acetoacetate (ACAC) and 3-hydroxybutyrate (3-HB) in blood. Samples were deproteinized with methanol-acetonitrile solution, and analytes were separated on an adamantyl group-bonded reverse phase column and detected in multiple reaction monitoring mode. Total analysis time was 4 min per sample. Method validation results displayed that limits of quantification were 10.0 μmol L(-1) for Lac and Pyr, and 5.0 μmol L(-1)for ACAC and 3-HB. The within- and between-run coefficients of variation were in the range of 1.2-6.4% for all analytes. The recoveries were ranged from 95.6 to 111.5%. The reference values of analytes were determined for the pediatric population. Duo to instability of Lac, Pyr and ACAC in vitro, a comprehensive stability assay was performed to determine optimal conditions for sample collection, pretreatment and storage. Results showed that precipitation of protein in blood at bedside combined with low storage temperature could effectively preserve the integrity of Lac, Pyr and 3-HB, but the precipitated protein accelerated degradation of ACAC. Isolation of supernatant fluid slowed degradation of ACAC. Supernatant samples could store at -20 °C for 10 days. The use of plasma or serum to determine these intermediates was not recommended. In this study, 450 samples from patients were analyzed, and 7 patients were diagnosed as congenital lactic acidosis. With the advantages of rapid, accurate and reliable, this method is very suitable for congenital lactic acidosis screening and researches related to energy metabolism. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Smart multi-channel two-dimensional micro-gas chromatography for rapid workplace hazardous volatile organic compounds measurement.

    Science.gov (United States)

    Liu, Jing; Seo, Jung Hwan; Li, Yubo; Chen, Di; Kurabayashi, Katsuo; Fan, Xudong

    2013-03-07

    We developed a novel smart multi-channel two-dimensional (2-D) micro-gas chromatography (μGC) architecture that shows promise to significantly improve 2-D μGC performance. In the smart μGC design, a non-destructive on-column gas detector and a flow routing system are installed between the first dimensional separation column and multiple second dimensional separation columns. The effluent from the first dimensional column is monitored in real-time and decision is then made to route the effluent to one of the second dimensional columns for further separation. As compared to the conventional 2-D μGC, the greatest benefit of the smart multi-channel 2-D μGC architecture is the enhanced separation capability of the second dimensional column and hence the overall 2-D GC performance. All the second dimensional columns are independent of each other, and their coating, length, flow rate and temperature can be customized for best separation results. In particular, there is no more constraint on the upper limit of the second dimensional column length and separation time in our architecture. Such flexibility is critical when long second dimensional separation is needed for optimal gas analysis. In addition, the smart μGC is advantageous in terms of elimination of the power intensive thermal modulator, higher peak amplitude enhancement, simplified 2-D chromatogram re-construction and potential scalability to higher dimensional separation. In this paper, we first constructed a complete smart 1 × 2 channel 2-D μGC system, along with an algorithm for automated control/operation of the system. We then characterized and optimized this μGC system, and finally employed it in two important applications that highlight its uniqueness and advantages, i.e., analysis of 31 workplace hazardous volatile organic compounds, and rapid detection and identification of target gas analytes from interference background.

  17. [Rapid determination of theophylline, theobromine and caffeine in dietary supplements containing guarana by ultra-performance liquid chromatography].

    Science.gov (United States)

    Hasegawa, Takashi; Takahashi, Kazunaga; Saijo, Masaaki; Ishii, Toshiyasu; Nagata, Tomoko

    2009-12-01

    A rapid and simple method for determination of theophylline, theobromine and caffeine in dietary supplements containing guarana by ultra-performance liquid chromatography (UPLC) has been developed. Theophylline, theobromine and caffeine were extracted from finely powdered samples with water in a boiling water bath for 20 min, then the extracts were filtered and the filtrates were subjected to UPLC. Liquid samples were diluted with water and filteres, and the filtrates were subjected to UPLC. UPLC separation was performed on an AQUITY UPLC BEH C18 column (2.1 mm i.d.x50 mm, 1.7 microm, Waters) with 10 mmol/L ammonium acetate buffer (pH 4.0)-acetonitrile gradient and eluates were monitored at 275 nm. The recoveries of theophylline (spiked at 200 microg/g [tablet] and 50 microg/mL [liquid]), theobromine (spiked at 200 microg/g [tablet] and 50 microg/mL [liquid]) and caffeine (spiked at 1,000 microg/g [tablet] and 250 microg/mL [liquid]) were 97.6-98.7%, 97.3-99.7%, 97.1-105.4%, respectively. The quantitation limits of theophylline, theobromine and caffeine were 10 microg/g (seed, seed powder, tablet and capsule) and 2.0 microg/mL (liquid) each. When this analytical method was applied to commercial dietary supplements, theophylline, theobromine and caffeine were found at concentrations of 4.45 mg/tablet, 5.48 mg/tablet, 139 mg/tablet, respectively. Taking 4 tablets of this product according to the directions on the package could be dangerous to consumers because of possible overdosing of these ingredients.

  18. Rapid methods to determine procyanidins, anthocyanins, theobromine and caffeine in rat tissues by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Serra, Aida; Macià, Alba; Romero, Maria-Paz; Piñol, Carme; Motilva, Maria-José

    2011-06-01

    Rapid, selective and sensitive methods were developed and validated to determine procyanidins, anthocyanins and alkaloids in different biological tissues, such as liver, brain, the aorta vein and adipose tissue. For this purpose, standards of procyanidins (catechin, epicatechin, and dimer B(2)), anthocyanins (cyanidin-3-glucoside and malvidin-3-glucoside) and alkaloids (theobromine, caffeine and theophylline) were used. The methods included the extraction of homogenized tissues by off-line liquid-solid extraction, and then solid-phase extraction to analyze alkaloids, or microelution solid-phase extraction plate for the analysis of procyanidins and anthocyanins. The eluted extracts were then analyzed by ultra-performance liquid chromatography-electrospray ionization-tandem mass spectrometry, using a triple quadrupole as the analyzer. The optimum extraction solution was water/methanol/phosphoric acid 4% (94/4.5/1.5, v/v/v). The extraction recoveries were higher than 81% for all the studied compounds in all the tissues, except the anthocyanins, which were between 50 and 65% in the liver and brain. In order to show the applicability of the developed methods, different rat tissues were analyzed to determine the procyanidins, anthocyanins and alkaloids and their generated metabolites. The rats had previously consumed 1g of a grape pomace extract (to analyze procyanidins and anthocyanins) or a cocoa extract (to analyze alkaloids) per kilogram of body weight. Different tissues were extracted 4h after administration of the respective extracts. The analysis of the metabolites revealed a hepatic metabolism of procyanidins. The liver was the tissue which produced a greater accumulation of these metabolites. Copyright © 2011 Elsevier B.V. All rights reserved.

  19. Potential of fermentation profiling via rapid measurement of amino acid metabolism by liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Dalluge, Joseph J; Smith, Sean; Sanchez-Riera, Fernando; McGuire, Chris; Hobson, Russell

    2004-07-16

    Monitoring amino acid metabolism during fermentation has significant potential from the standpoint of strain selection, optimizing growth and production in host strains, and profiling microbial metabolism and growth state. A method has been developed based on rapid quantification of underivatized amino acids using liquid chromatography-electrospray tandem mass spectrometry (LC-MS-MS) to monitor the metabolism of 20 amino acids during microbial fermentation. The use of a teicoplanin-based chiral stationary phase coupled with electrospray tandem mass spectrometry allows complete amino acid analyses in less than 4 min. Quantification is accomplished using five isotopically labeled amino acids as internal standards. Because comprehensive chromatographic separation and derivatization are not required, analysis time is significantly less than traditional reversed- or normal-phase LC-based amino acid assays. Intra-sample precisions for amino acid measurements in fermentation supernatants using this method average 4.9% (R.S.D.). Inter-day (inter-fermentation) precisions for individual amino acid measurements range from 4.2 to 129% (R.S.D.). Calibration curves are linear over the range 0-300 microg/ml, and detection limits are estimated at 50-450 ng/ml. Data visualization techniques for constructing semi-quantitative fermentation profiles of nitrogen source utilization have also been developed and implemented, and demonstrate that amino acid profiles generally correlate with observed growth profiles. Further, cellular growth events, such as lag-time and cell lysis can be detected using this methodology. Correlation coefficients for the time profiles of each amino acid measured illustrate that while several amino acids are differentially metabolized in similar fermentations, a select group of amino acids display strong correlations in these samples, indicating a sub-population of analytes that may be most useful for fermentation profiling.

  20. Lithium-Ion Battery Online Rapid State-of-Power Estimation under Multiple Constraints

    Directory of Open Access Journals (Sweden)

    Shun Xiang

    2018-01-01

    Full Text Available The paper aims to realize a rapid online estimation of the state-of-power (SOP with multiple constraints of a lithium-ion battery. Firstly, based on the improved first-order resistance-capacitance (RC model with one-state hysteresis, a linear state-space battery model is built; then, using the dual extended Kalman filtering (DEKF method, the battery parameters and states, including open-circuit voltage (OCV, are estimated. Secondly, by employing the estimated OCV as the observed value to build the second dual Kalman filters, the battery SOC is estimated. Thirdly, a novel rapid-calculating peak power/SOP method with multiple constraints is proposed in which, according to the bisection judgment method, the battery’s peak state is determined; then, one or two instantaneous peak powers are used to determine the peak power during T seconds. In addition, in the battery operating process, the actual constraint that the battery is under is analyzed specifically. Finally, three simplified versions of the Federal Urban Driving Schedule (SFUDS with inserted pulse experiments are conducted to verify the effectiveness and accuracy of the proposed online SOP estimation method.

  1. Comparison of Gas Chromatography-Mass Spectrometry and Gas Chromatography-Tandem Mass Spectrometry with Electron Ionization and Negative-Ion Chemical Ionization for Analyses of Pesticides at Trace Levels in Atmospheric Samples

    Science.gov (United States)

    Raina, Renata; Hall, Patricia

    2008-01-01

    A comparison of detection limits of gas chromatography-mass spectrometry (GC-MS) in selected ion monitoring (SIM) with gas chromatography-tandem mass spectrometry (GC-MS/MS) in selected reaction monitoring (SRM) mode with both electron ionization (EI) and negative-ion chemical ionization (NCI) are presented for over 50 pesticides ranging from organochlorines (OCs), organophosphorus pesticides (OPs) and pre-emergent herbicides used in the Canadian prairies (triallate, trifluralin, ethalfluralin). The developed GC-EI/SIM, GC-NCI/SIM, and GC-NCI/SRM are suitable for the determination of pesticides in air sample extracts at concentrations ethion, and OCs: alachlor, aldrin, perthane, and DDE, DDD, DDT). PMID:19609395

  2. Metabolite Profile of Salidroside in Rats by Ultraperformance Liquid Chromatography Coupled with Quadrupole Time-of-Flight Mass Spectrometry and High-Performance Liquid Chromatography Coupled with Quadrupole-Linear Ion Trap Mass Spectrometry.

    Science.gov (United States)

    Hu, Zhiwei; Wang, Ziming; Liu, Yong; Wu, Yan; Han, Xuejiao; Zheng, Jian; Yan, Xiufeng; Wang, Yang

    2015-10-21

    In the present work, the salidroside metabolite profile in rat urine was investigated, and subsequently the metabolic pathways of salidroside were proposed. After administrations of salidroside at an oral dose of 100 or 500 mg/kg, rat urine samples were collected and pretreated with methanol to precipitate the proteins. The pretreated samples were analyzed by an Acquity ultraperformance liquid chromatography (UPLC) coupled with an HSS T3 column and detected by quadrupole time-of-flight mass spectrometry (Q-TOF-MS) or high-performance liquid chromatography coupled with hybrid triple-quadrupole linear ion trap mass spectrometry (HPLC/Q-trap-MS). A total of eight metabolites were detected and identified on the basis of the characteristics of their protonated ions in the urine samples. The results elucidated that salidroside was metabolized via glucuronidation, sulfation, deglycosylation, hydroxylation, methylation, and dehydroxylation pathways in vivo.

  3. High performance ion chromatography of transition metal chelate complexes and aminopolycarboxylate ligands.

    Science.gov (United States)

    Tófalvi, Renáta; Horváth, Krisztián; Hajós, Péter

    2013-01-11

    A simple ion chromatographic method was developed for the separation of transition metal chelates (CuEDTA, CuDCTA, ZnEDTA, ZnDCTA) and free anionic complexing ligands (EDTA, DCTA) using alkaline carbonate eluents and conductivity detection. The complex equilibria and kinetic process of separations were studied in order to understand major factors in the control of selectivity and retention order of complex anions. A systematic study was applied to identify the additional peaks of the system as NaEDTA(3-), NaHEDTA(2-), Na(2)EDTA(2-), EDTA(4-)/HEDTA(3-), DCTA(4-)/HDCTA(-3). On the basis of microequilibrium considerations of chelating ligand, it was shown that one should expect the peaks of sodium chelates when the ligand is in excess in the sample solution. The probability density function was introduced for calculation of complex chromatograms, because complexing ligands can exist in at least two different interconvertible forms in the presence of metal ion. The chromatogram of interconverting chelate species can be given as the sum of probability density functions (P) weighed by the molar fractions of complexed (Φ(ML)) and dissociated (Φ(L)) forms. The influences of kinetic rate of complex formation and dissociation on the distribution of components between eluents and ion exchange stationary phases were quantitatively described and demonstrated by elution profiles. The applicability of the developed method is represented by the simultaneous analysis of transition metal chelates and inorganic anions. ICP-AES analysis and FTIR-ATR technique were used for confirmation of IC results for metals and ligands, respectively. Collection protocols for the heart-cutting procedure of chromatograms were applied in the analysis of target components. The limit of detection and linearity of the method in the range of 0.01-0.25 mM sample concentration were also presented. Copyright © 2012 Elsevier B.V. All rights reserved.

  4. Determination of haloacetic acids in water by ion chromatography--method development.

    Science.gov (United States)

    Lopez-Avila, V; Liu, Y; Charan, C

    1999-01-01

    The microextraction/ion chromatographic (IC) method developed in this study involves extraction of 9 haloacetic acids (HAAs) from aqueous samples (acidified with sulfuric acid to a pH of copper sulfate pentahydrate and sodium sulfate) with methyl tert-butyl ether (MTBE), back extraction into reagent water, and analysis by IC with conductivity detection. The separation column consists of an Ion Pac AG-11 (2 mm id x 50 mm length) guard column and an Ion Pac AS-11 (2 mm id x 250 mm length) analytical column, and the concentration column is a 4 mm id x 35 mm length Dionex TAC-LP column. Use of the 2 mm id Dionex AS-11 column improved detection limits especially for trichloracetic acid (TCAA), bromodichloroacetic acid (BDCAA), dibromochloroacetic acid (DBCAA), and tribromoacetic acid (TBAA). The peak interfering with BCAA elutes at the same retention time as nitrate; however, we have not confirmed the presence of nitrate. Stability studies indicate that HAAs are stable in water for at least 8 days when preserved with ammonium chloride at 100 mg/L and stored at 4 degrees C in the dark. At day 30, recoveries were still high (e.g., 92.1-106%) for dichloroacetic acid (DCAA), BCAA, dibromoacetic acid (DBAA), trichloroacetic acid (TCAA), BDCAA, and DBCAA. However, recoveries of monochloroacetic acid (MCAA), monobromoacetic acid (MBAA), and TBAA were only 54.6, 56.8, and 66.8%, respectively. Stability studies of HAAs in H2SO4-saturated MTBE indicate that all compounds except TBAA are stable for 48 h when stored at 4 degrees C in the dark. TBAA recoveries dropped to 47.1% after 6 h of storage and no TBAA was detected after 48 h of storage. The method described here is only preliminary and was tested in only one laboratory. Additional research is needed to improve method performance.

  5. [Determination of trace bromate in drinking water by ion chromatography with suppressed conductivity detection].

    Science.gov (United States)

    Ying, Bo; Li, Shumin; Yue, Yinling; Xueli, E

    2006-05-01

    Bromate is a common disinfection by-product produced from the ozonation of source water containing bromide. An ion exchange chromatographic method with suppressed conductivity detection for the determination of trace bromate in drinking water was developed. The separation of the bromate in drinking water was achieved on a Metrosep A Supp 5 anion exchange column and a Metrosep A Supp 4/5 Guard column with a carbonate eluent. A new dual suppressed system, an MSM II chemical suppressor combined with a CO2 suppressor, was used to suppress the background conductivity, and to improve the detection limit of bromate. Ion chromatographic experiments were carried out by using a Metrosep A Supp 5 anion exchange column with a suppressed conductivity detector and an eluent of 3.2 mmoL/L Na2CO3-1.0 mmol/L NaHCO3 at a flow rate of 0.65 mL/min. This method had good linearity (r = 0.9999) in the range of 5-100 microg/L and high precision (relative standard deviation (RSD) water, pure water and mineral water were 96.1%-107%, and the detection limit for bromate was 0.50 microg/L. This method has a simple operation procedure, good separation results, high sensitivity and good repeatability. It can be used as a standard method for the determination of bromate in drinking water.

  6. Simultaneous determination of inorganic anions and cations in explosive residues by ion chromatography.

    Science.gov (United States)

    Meng, Hong-Bo; Wang, Tian-Ran; Guo, Bao-Yuan; Hashi, Yuki; Guo, Can-Xiong; Lin, Jin-Ming

    2008-07-15

    A non-suppressed ion chromatographic method by connecting anion-exchange and cation-exchange columns directly was developed for the separation and determination of five inorganic anions (sulfate, nitrate, chloride, nitrite, and chlorate) and three cations (sodium, ammonium, and potassium) simultaneously in explosive residues. The mobile phase was composed of 3.5mM phthalic acid with 2% acetonitrile and water at flow rate of 0.2 mL/min. Under the optimal conditions, the eight inorganic ions were completely separated and detected simultaneously within 16 min. The limits of detection (S/N=3) of the anions and cations were in the range of 50-100 microg/L and 150-320 microg/L, respectively, the linear correlation coefficients were 0.9941-0.9996, and the R.S.D. of retention time and peak area were 0.10-0.29% and 5.65-8.12%, respectively. The method was applied successfully to the analysis of the explosive samples with satisfactory results.

  7. Two-step ion-exchange chromatographic purification combined with reversed-phase chromatography to isolate C-peptide for mass spectrometric analysis.

    Science.gov (United States)

    Kabytaev, Kuanysh; Durairaj, Anita; Shin, Dmitriy; Rohlfing, Curt L; Connolly, Shawn; Little, Randie R; Stoyanov, Alexander V

    2016-02-01

    A liquid chromatography with mass spectrometry on-line platform that includes the orthogonal techniques of ion exchange and reversed phase chromatography is applied for C-peptide analysis. Additional improvement is achieved by the subsequent application of cation- and anion-exchange purification steps that allow for isolating components that have their isoelectric points in a narrow pH range before final reversed-phase mass spectrometry analysis. The utility of this approach for isolating fractions in the desired "pI window" for profiling complex mixtures is discussed. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Miniaturized GC/MS instrumentation for in situ measurements: micro gas chromatography coupled with miniature quadrupole array and paul ion trap mass spectrometers

    Science.gov (United States)

    Holland, P.; Chutjian, A.; Darrach, M.; Orient, O.

    2002-01-01

    Miniaturized chemical instrumentation is needed for in situ measurements in planetary exploration and other spaceflight applications where factors such as reduction in payload requirements and enhanced robustness are important. In response to this need, we are 'continuing to develop miniaturized GC/MS instrumentation which combines chemical separations by gas chromatography (GC) with mass spectrometry (MS) to provide positive identification of chemical compounds in complex mixtures of gases, such as those found in the International Space Station's cabin atmosphere. Our design approach utilizes micro gas chromatography components coupled with either a miniature quadrupole mass spectrometer array (QMSA) or compact, high-resolution Paul ion trap.

  9. Separation of polar betalain pigments from cacti fruits of Hylocereus polyrhizus by ion-pair high-speed countercurrent chromatography.

    Science.gov (United States)

    Wybraniec, Sławomir; Stalica, Paweł; Jerz, Gerold; Klose, Bettina; Gebers, Nadine; Winterhalter, Peter; Spórna, Aneta; Szaleniec, Maciej; Mizrahi, Yosef

    2009-10-09

    Polar betacyanin pigments together with betaxanthins from ripe cactus fruits of Hylocereus polyrhizus (Cactaceae) were fractionated by means of preparative ion-pair high-speed countercurrent chromatography (IP-HSCCC) also using the elution-extrusion (EE) approach for a complete pigment recovery. HSCCC separations were operated in the classical 'head-to-tail' mode with an aqueous mobile phase. Different CCC solvent systems were evaluated in respect of influence and effectiveness of fractionation capabilities to separate the occurring pigment profile of H. polyrhizus. For that reason, the additions of two different volatile ion-pair forming perfluorinated carboxylic acids (PFCA) were investigated. For a direct comparison, five samples of Hylocereus pigment extract were run on preparative scale (900 mg) in 1-butanol-acetonitrile-aqueous TFA 0.7% (5:1:6, v/v/v) and the modified systems tert.-butyl methyl ether-1-butanol-acetonitrile-aqueous PFCA (2:2:1:5, v/v/v/v) using 0.7% and 1.0% trifluoroacetic acid (TFA) or heptafluorobutyric acid (HFBA) in the aqueous phase, respectively. The chemical affinity to the organic stationary CCC solvent phases and in consequence the retention of these highly polar betalain pigments was significantly increased by the use of the more lipophilic fluorinated ion-pair reagent HFBA instead of TFA. The HFBA additions separated more effectively the typical cacti pigments phyllocactin and hylocerenin from betanin as well as their iso-forms. Unfortunately, similar K(D) ratios and selectivity factors alpha around 1.0-1.1 in all tested solvent systems proved that the corresponding diastereomers, 15S-type pigments cannot be resolved from the 15R-epimers (iso-forms). Surprisingly, additions of the stronger ion-pair reagent (HFBA) resulted in a partial separation of hylocerenin from phyllocactin which were not resolved in the other solvent systems. The pigments were detected by means of HPLC-DAD and HPLC-electrospray ionization-MS using also

  10. A mechanistic model of ion-exchange chromatography on polymer fiber stationary phases.

    Science.gov (United States)

    Winderl, Johannes; Hahn, Tobias; Hubbuch, Jürgen

    2016-12-02

    Fibers are prominent among novel stationary phase supports for preparative chromatography. Several recent studies have highlighted the potential of fiber-based adsorbents for high productivity downstream processing in both batch and continuous mode, but so far the development of these materials and of processes employing these materials has solely been based on experimental data. In this study we assessed whether mechanistic modeling can be performed on fiber-based adsorbents. With a column randomly filled with short cut hydrogel grafted anion exchange fibers, we tested whether tracer, linear gradient elution, and breakthrough data could be reproduced by mechanistic models. Successful modeling was achieved for all of the considered experiments, for both non-retained and retained molecules. For the fibers used in this study the best results were obtained with a transport-dispersive model in combination with a steric mass action isotherm. This approach accurately accounted for the convection and dispersion of non-retained tracers, and the breakthrough and elution behaviors of three different proteins with sizes ranging from 6 to 160kDa were accurately modeled, with simulation results closely resembling the experimental data. The estimated model parameters were plausible both from their physical meaning, and from an analysis of the underlying model assumptions. Parameters were determined within good confidence levels; the average confidence estimate was below 7% for confidence levels of 95%. This shows that fiber-based adsorbents can be modeled mechanistically, which will be valuable for the future design and evaluation of these novel materials and for the development of processes employing such materials. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Measurement of gas-phase ammonia and amines in air by collection onto an ion exchange resin and analysis by ion chromatography

    Science.gov (United States)

    Dawson, M. L.; Perraud, V.; Gomez, A.; Arquero, K. D.; Ezell, M. J.; Finlayson-Pitts, B. J.

    2014-08-01

    Ammonia and amines are common trace gases in the atmosphere and have a variety of both biogenic and anthropogenic sources, with a major contribution coming from agricultural sites. In addition to their malodorous nature, both ammonia and amines have been shown to enhance particle formation from acids such as nitric, sulfuric and methanesulfonic acids, which has implications for visibility, human health and climate. A key component of quantifying the effects of these species on particle formation is accurate gas-phase measurements in both laboratory and field studies. However, these species are notoriously difficult to measure as they are readily taken up on surfaces, including onto glass surfaces from aqueous solution as established in the present studies. We describe here a novel technique for measuring gas-phase ammonia and amines that involves uptake onto a weak cation exchange resin followed by extraction and analysis using ion chromatography. Two variants - one for parts per billion concentrations in air and the second with lower (parts per trillion) detection limits - are described. The latter involves the use of a custom-designed high-pressure cartridge to hold the resin for in-line extraction. These methods avoid the use of sampling lines, which can lead to significant inlet losses of these compounds. They also have the advantages of being relatively simple and inexpensive. The applicability of this technique to ambient air is demonstrated in measurements made near a cattle farm in Chino, CA.

  12. A Facile, Nonreactive Hydrogen Peroxide (H2O2) Detection Method Enabled by Ion Chromatography with UV Detector.

    Science.gov (United States)

    Song, Mingrui; Wang, Junli; Chen, Baiyang; Wang, Lei

    2017-11-07

    Hydrogen peroxide (H2O2) is ubiquitous in the natural environment, and it is now widely used for pollutant control in water and wastewater treatment processes. However, current analytical methods for H2O2 inevitably require reactions between H2O2 and other reactants to yield signals and are thus likely subjective to the interferences of coexisting colored, oxidative, and reductive compounds. In order to overcome these barriers, we herein for the first time propose to analyze H2O2 by ion chromatography (IC) using an ultraviolet (UV) detector. The proposal is based on two principles: first, that H2O2 can deprotonate to hydroperoxyl ion (HO2-) when eluent pH is higher than the acid-dissociation coefficient of H2O2 (pKa = 11.6); and second, that after separation from other compounds via IC column, H2O2 can be quantified by a UV detector. Under favorable operating conditions, this method has successfully achieved acceptable recoveries (>91%) of H2O2 dosed to ultrapure and natural waters, a calibration curve with R2 > 0.99 for a wide range of H2O2 concentrations from 0.1 to 50 mg/L and a method detection limit of 0.027 mg/L. In addition, this approach was shown to be capable of distinguishing H2O2 from anions (e.g., fluoride and chloride) and organics (e.g., glycolate) and monochloramine, suggesting that it is insensitive to many neighboring compounds as long as they do not react quickly with H2O2. Hence, this study proves the combination of IC and UV detector a facile and reliable method for H2O2 measurement.

  13. [Determination of total cyanides and sulfides in wastewater using ion chromatography coupled with ultraviolet photo-dissociation/gas-membrane diffusion].

    Science.gov (United States)

    Lu, Keping

    2015-03-01

    An automated system for the determination of total cyanides and sulfides in wastewater has been developed using flow injection, ultraviolet (UV) photo-dissociation, gas-membrane diffusion, column trapping, ion chromatography separation and pulsed amperometric detection. When the sample was mixed with sulfuric acid and hypophosphorous acid medium containing the appropriate amount of sulfamic acid, ascorbic acid, EDTA and citric acid, metal-cyanide complexes such as Fe (CN)3-(6) can be photo-dissociated by 312 nm UV light, which results in hydrogen cyanide ( HCN) and similarly, sulfides release hydrogen sulfide (H2S). These products were diffused through a 0.45 µm hydrophobic porous polypropylene membrane and were then absorbed in the dilute NaOH solution, concentrated with a Metrosep A PCC 1 HC/4.0 column, separated on an IonPac AS7 column, and finally detected by the pulsed amperometric detector with Ag electrode. The total cyanides and sulfides were good linear in the range of 0.5-1,000 µg/L with correlation coefficients of 0.998 9 and 0.999 7 respectively. The recoveries were 93%-102% and the limits of detection were 0.5 µg/L for total cyanides and 1.0 µg/L for sulfides under the conditions of the sample volume of 100 µL and the signal to noise ratio of 5. The sample throughput of the system was six samples per hour. The results from this new method have been compared with the ones obtained with the standard method, which shows a good agreement.

  14. Separation of betalains from berries of Phytolacca americana by ion-pair high-speed counter-current chromatography.

    Science.gov (United States)

    Jerz, Gerold; Skotzki, Tanja; Fiege, Kathrin; Winterhalter, Peter; Wybraniec, Sławomir

    2008-05-09

    The first preparative fractionation of betalain pigments by means of ion-pair high-speed counter-current chromatography (IP-HSCCC) from berry extracts of Phytolacca americana (Phytolaccaceae) is presented. A novel HSCCC solvent system consisting of 1-butanol-acetonitrile-water (5:1:6, v/v/v) was applied using ion-pair forming trifluoroacetic acid at low concentration (0.7%, v/v). Affinity of polar betacyanins and betaxanthins to the organic stationary phase of the biphasic HSCCC solvent mixture was considerably improved. Partitioning coefficient values and influence of increasing trifluoroacetic acid additions to the biphasic solvent mixture were measured for all identified betacyanins and betaxanthins. Gentle separation by IP-HSCCC of the injected pigment extract (900 mg) yielded sufficient amounts of the principal pigments 15S-betanin/15R-isobetanin. The pure epimers separated by C18-HPLC were immediately studied by one- and two-dimensional NMR. In the recovered fractions, minor concentrated betacyanins and betaxanthins were significantly enriched by IP-HSCCC and were detected for the first time in the extracts of P. americana. IP-HSCCC and C18-HPLC were shown to be complementary techniques in the isolation procedure of recovering minor concentrated, highly polar and chemically instable betacyanins and betaxanthin from complex plant matrices. Altogether, identification of 17 betalains was achieved by HPLC-diode array detection-electrospray ionization MS/MS in the HSCCC fractions with their respective isomers, also resulting in the tentative elucidation of betacyanins with novel salicylic acid substitution pattern in the berry extracts of P. americana.

  15. Rapid analysis of pesticide residues in drinking water samples by dispersive solid-phase extraction based on multiwalled carbon nanotubes and pulse glow discharge ion source ion mobility spectrometry.

    Science.gov (United States)

    Zou, Nan; Gu, Kejia; Liu, Shaowen; Hou, Yanbing; Zhang, Jialei; Xu, Xiang; Li, Xuesheng; Pan, Canping

    2016-03-01

    An analytical method based on dispersive solid-phase extraction with a multiwalled carbon nanotubes sorbent coupled with positive pulse glow discharge ion mobility spectrometry was developed for analysis of 30 pesticide residues in drinking water samples. Reduced ion mobilities and the mass-mobility correlation of 30 pesticides were measured. The pesticides were divided into five groups to verify the separation capability of pulse glow discharge in mobility spectrometry. The extraction conditions such as desorption solvent, ionic strength, conditions of adsorption and desorption, the amounts of multiwalled carbon nanotubes, and solution pH were optimized. The enrichment factors of pesticides were 5.4- to 48.7-fold (theoretical enrichment factor was 50-fold). The detection limits of pesticides were 0.01∼0.77 μg/kg. The linear range was 0.005-0.2 mg/L for pesticide standard solutions, with determination coefficients from 0.9616 to 0.9999. The method was applied for the analysis of practical and spiked drinking water samples. All results were confirmed by high-performance liquid chromatography with tandem mass spectrometry. The proposed method was proven to be a commendably rapid screening qualitative and semiquantitative technique for the analysis of pesticide residues in drinking water samples on site. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Modeling of salt and pH gradient elution in ion-exchange chromatography.

    Science.gov (United States)

    Schmidt, Michael; Hafner, Mathias; Frech, Christian

    2014-01-01

    The separation of proteins by internally and externally generated pH gradients in chromatofocusing on ion-exchange columns is a well-established analytical method with a large number of applications. In this work, a stoichiometric displacement model was used to describe the retention behavior of lysozyme on SP Sepharose FF and a monoclonal antibody on Fractogel SO3 (S) in linear salt and pH gradient elution. The pH dependence of the binding charge B in the linear gradient elution model is introduced using a protein net charge model, while the pH dependence of the equilibrium constant is based on a thermodynamic approach. The model parameter and pH dependences are calculated from linear salt gradient elutions at different pH values as well as from linear pH gradient elutions at different fixed salt concentrations. The application of the model for the well-characterized protein lysozyme resulted in almost identical model parameters based on either linear salt or pH gradient elution data. For the antibody, only the approach based on linear pH gradients is feasible because of the limited pH range useful for salt gradient elution. The application of the model for the separation of an acid variant of the antibody from the major monomeric form is discussed. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Custom-tailored adsorbers: A molecular dynamics study on optimal design of ion exchange chromatography material.

    Science.gov (United States)

    Lang, Katharina M H; Kittelmann, Jörg; Pilgram, Florian; Osberghaus, Anna; Hubbuch, Jürgen

    2015-09-25

    The performance of functionalized materials, e.g., ion exchange resins, depends on multiple resin characteristics, such as type of ligand, ligand density, the pore accessibility for a molecule, and backbone characteristics. Therefore, the screening and identification process for optimal resin characteristics for separation is very time and material consuming. Previous studies on the influence of resin characteristics have focused on an experimental approach and to a lesser extent on the mechanistic understanding of the adsorption mechanism. In this in silico study, a previously developed molecular dynamics (MD) tool is used, which simulates any given biomolecule on resins with varying ligand densities. We describe a set of simulations and experiments with four proteins and six resins varying in ligand density, and show that simulations and experiments correlate well in a wide range of ligand density. With this new approach simulations can be used as pre-experimental screening for optimal adsorber characteristics, reducing the actual number of screening experiments, which results in a faster and more knowledge-based development of custom-tailored adsorbers. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Development of a rapid diagnostic method for identification of Staphylococcus aureus and antimicrobial resistance in positive blood culture bottles using a PCR-DNA-chromatography method.

    Science.gov (United States)

    Ohshiro, Takeya; Miyagi, Chihiro; Tamaki, Yoshikazu; Mizuno, Takuya; Ezaki, Takayuki

    2016-06-01

    Blood culturing and the rapid reporting of results are essential for infectious disease clinics to obtain bacterial information that can affect patient prognosis. When gram-positive coccoid cells are observed in blood culture bottles, it is important to determine whether the strain is Staphylococcus aureus and whether the strain has resistance genes, such as mecA and blaZ, for proper antibiotic selection. Previous work led to the development of a PCR method that is useful for rapid identification of bacterial species and antimicrobial susceptibility. However, that method has not yet been adopted in community hospitals due to the high cost and methodological complexity. We report here the development of a quick PCR and DNA-chromatography test, based on single-tag hybridization chromatography, that permits detection of S. aureus and the mecA and blaZ genes; results can be obtained within 1 h for positive blood culture bottles. We evaluated this method using 42 clinical isolates. Detection of S. aureus and the resistance genes by the PCR-DNA-chromatography method was compared with that obtained via the conventional identification method and actual antimicrobial susceptibility testing. Our method had a sensitivity of 97.0% and a specificity of 100% for the identification of the bacterial species. For the detection of the mecA gene of S. aureus, the sensitivity was 100% and the specificity was 95.2%. For the detection of the blaZ gene of S. aureus, the sensitivity was 100% and the specificity was 88.9%. The speed and simplicity of this PCR-DNA-chromatography method suggest that our method will facilitate rapid diagnoses. Copyright © 2016 Japanese Society of Chemotherapy and The Japanese Association for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  19. Rapid determination of benzodiazepines, zolpidem and their metabolites in urine using direct injection liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Jeong, Yu-Dong; Kim, Min Kyung; Suh, Sung Ill; In, Moon Kyo; Kim, Jin Young; Paeng, Ki-Jung

    2015-12-01

    Benzodiazepines and zolpidem are generally prescribed as sedative, hypnotics, anxiolytics or anticonvulsants. These drugs, however, are frequently misused in drug-facilitated crime. Therefore, a rapid and simple liquid chromatography-tandem mass spectrometric (LC-MS/MS) method was developed for identification and quantification of benzodiazepines, zolpidem and their metabolites in urine using deuterium labeled internal standards (IS). Urine samples (120 μL) mixed with 80 μL of the IS solution were centrifuged. An aliquot (5 μL) of the sample solution was directly injected into the LC-MS/MS system for analysis. The mobile phases consisted of water and acetonitrile containing 2mM ammonium trifluoroacetate and 0.2% acetic acid. The analytical column was a Zorbax SB-C18 (100 mm × 2.1 mm i.d., 3.5 μm, Agilent). The separation and detection of 18 analytes were achieved within 10 min. Calibration curves were linear over the concentration ranges of 0.5-20 ng/mL (zolpidem), 1.0-40 ng/mL (flurazepam and temazepam), 2.5-100 ng/mL (7-aminoclonazepam, 1-hydroxymidazolam, midazolam, flunitrazepam and alprazolam), 5.0-200 ng/mL (zolpidem phenyl-4-carboxylic acid, α-hydroxyalprazolam, oxazepam, nordiazepam, triazolam, diazepam and α-hydroxytriazolam), 10-400 ng/mL (lorazepam and desalkylflurazepam) and 10-100 ng/mL (N-desmethylflunitrazepam) with the coefficients of determination (r(2)) above 0.9971. The dilution integrity of the analytes was examined for supplementation of short linear range. Dilution precision and accuracy were tested using two, four and ten-folds dilutions and they ranged from 3.7 to 14.4% and -12.8 to 12.5%, respectively. The process efficiency for this method was 63.0-104.6%. Intra- and inter-day precisions were less than 11.8% and 9.1%, while intra- and inter-day accuracies were less than -10.0 to 8.2%, respectively. The lower limits of quantification were lower than 10 ng/mL for each analyte. The applicability of the developed method was successfully

  20. Application of Liquid Chromatography/Ion Trap Mass Spectrometry Technique to Determine Ergot Alkaloids in Grain Products

    Directory of Open Access Journals (Sweden)

    Krystyna Szymczyk

    2015-01-01

    Full Text Available A liquid chromatography/ion trap mass spectrometry-based method to determine six ergot alkaloids and their isomers is presented. The samples were cleaned on neutral alumina-based solid-phase extraction cartridges. The following method parameters were obtained (depending on the analyte and spiking level: method recovery from 63.0 to 104.6 %, relative standard deviation below 18 %, linear range from 1 to 325 μg/kg, linear correlation coefficient not less than 0.98. The developed analytical procedure was applied to determine the levels of ergot alkaloids in 65 samples of selected rye-based food products (flour– 34 samples, bran – 12 samples, rye – 18 samples, flakes – 1 sample. Measurable levels of alkaloids were found in majority of the analysed samples, particularly in rye flour. Additionally, alkaloids were determined in ergot sclerotia isolated from rye grains. Total content was nearly 0.01 % (97.9 mg/kg. However, the alkaloid profi le was dominated by ergocristine at 45.6 % (44.7 mg/kg, an alkaloid not commonly found in the tested food products. Ergocorninine at 0.2 % (0.2 mg/kg was the least abundant alkaloid.

  1. Purification of recombinant aprotinin produced in transgenic corn seed: separation from CTI utilizing ion-exchange chromatography

    Directory of Open Access Journals (Sweden)

    A. R. Azzoni

    2005-09-01

    Full Text Available Protein expression in transgenic plants is considered one of the most promising approaches for producing pharmaceutical proteins. As has happened with other recombinant protein production schemes, the downstream processing (dsp of these proteins produced in plants is key to the technical and economic success of large-scale applications. Since dsp of proteins produced transgenically in plants has not been extensively studied, it is necessary to broaden the investigation in this field in order to more precisely evaluate the commercial feasibility of this route of expression. In this work, we studied the substitution of an IMAC chromatographic step, described in previous work (Azzoni et al., 2002, with ion-exchange chromatography on SP Sepharose Fast Flow resin as the second step in the purification of recombinant aprotinin from transgenic maize seed. The main goal of this second purification step is to separate the recombinant aprotinin from the native corn trypsin inhibitor. Analysis of the adsorption isotherms determined at 25°C under different conditions allowed selection of 0.020 M Tris pH 8.5 as the adsorption buffer. The cation-exchange chromatographic process produced a high-purity aprotinin that was more than ten times more concentrated than that generated using an IMAC step.

  2. Characterization of Leucaena (Leucaena leucephala oil by direct analysis in real time (DART ion source and gas chromatography

    Directory of Open Access Journals (Sweden)

    M. Alam

    2017-06-01

    Full Text Available For the first time, we report the characterization of triacylglycerols and fatty acids in Leucaena (Leucaena leucephala oil [LUCO], an unexplored nontraditional non-medicinal plant belonging to the family Fabaceae. LUCO was converted to fatty acid methyl esters (FAMEs. We analyzed the triacylglycerols (TAGs of pure LUCO and their FAMEs by time-of-flight mass spectrometry (TOF-MS followed by multivariate analysis for discrimination among the FAMEs. Our investigations for the analysis of LUCO samples represent noble features of glycerides. A new type of ion source, coupled with high-resolution TOF-MS was applied for the comprehensive analysis of triacylglycerols. The composition of fatty acid based LUCO oil was studied using Gas Chromatography (GC-FID. The major fatty acid components of LUCO oil are linoleic acid (52.08% oleic acid (21.26%, palmitic acid (7.91% and stearic acid (6.01%. A metal analysis in LUCO was done by Inductively Coupled Plasma Mass Spectrometry (ICP-MS. The structural elucidation and thermal stability of LUCO were studied by FT-IR, 1H NMR, 13C NMR spectroscopic techniques and TGA-DSC, respectively. We also measured the cytotoxicity of LUCO.

  3. Simplified purification approach of urinary neutrophil gelatinase-associated lipocalin by tangential flow filtration and ion exchange chromatography.

    Science.gov (United States)

    Shukla, Kunal K; Badgujar, Shamkant B; Bhanushali, Paresh B; Sabharwal, Sushma G

    2017-04-15

    This investigation reports a simplified approach for the purification of urinary siderocalin known as neutrophil gelatinase-associated lipocalin (NGAL). Urinary NGAL was purified by tangential flow filtration and ion exchange chromatography. Isolated NGAL was analyzed by SDS-PAGE, immunoblotting and mass spectrometry (MS). The relative molecular mass of NGAL is 23674Da. Peptide mass fingerprinting of the purified NGAL yielded peptides that partially matched with known sequence of P80188 (NGAL_HUMAN). The tryptic digestion profile of isolated NGAL infers that it may be unique and additive molecule in the dictionary of urinary proteins. This is the first report of purification and validation of urinary NGAL from large volume sample by using tangential flow filtration and peptide sequencing respectively. This cost-effective and simplified approach to purification of NGAL, together with the easy availability of urine sample makes the large-scale production of NGAL possible, allowing exploration of various bioclinical as well as biodiagnostic applications. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. +Facile extraction of azide in sartan drugs using magnetized anion-exchange metal-organic frameworks prior to ion chromatography.

    Science.gov (United States)

    Zhang, Sainan; Han, Peipei; Xia, Yan

    2017-09-08

    Quaternary amine functionalized metal-organic framework MIL-101(Cr) (MIL-101(Cr)-NMe3) was prepared as the sorbent for the magnetic solid-phase extraction (MSPE) of azide from sartan drugs before ion chromatography determination. Magnetization of MIL-101-NMe3 were achieved concurrently by adding MIL-101-NMe3 and Fe3O4@SiO2 to the sample solution under ultrasonication. The prepared Fe3O4@SiO2/MIL-101-NMe3 gave the adsorption capacity of 37.5mgg-1. The developed method had a detection limit of 0.24μgL-1 and quantitation limit of 0.79μgL-1 for azide. The relative standard deviations for the intra-day retention time and peak area were 0.52% and 0.36% (n=5), respectively. The developed method was successfully applied for the determination of azide in sartan drugs with the recoveries from 96.5% to 100.5%. Copyright © 2017. Published by Elsevier B.V.

  5. Separation of boron from borated paraffin wax by pyrohydrolysis and alkali extraction methods and its determination using ion chromatography.

    Science.gov (United States)

    Raut, Vaibhavi Vishwajeet; Jeyakumar, Subbiah; Shah, Dipti Jayesh; Thakur, Uday Kumar; Tomar, Bhupendra Singh; Ramakumar, Karanam Lakshminarayana

    2015-01-01

    A method based on the pyrohydrolysis extraction of boron and its quantification with ion chromatography was proposed for paraffin waxes borated with H3BO3 and B4C. The optimum pyrohydrolysis conditions were identified. Wax samples were mixed with U3O8, which prevents the sample from flare up, and also accelerates the extraction of boron. Pyrohydrolysis was carried out with moist O2 at 950°C for 60 and 90 min for wax with H3BO3 and wax with B4C, respectively. Two simple methods of separation based on alkali extraction and melting wax in alkali were also developed exclusively for wax with H3BO3. In all the separations, the recovery of B was above 98%. During IC separation, B was separated as boron-mannitol anion complex. Linear calibration was obtained it between 0.1 and 50 ppm of B, and LOD was calculated as 5 ppb (S/N = 3). The reproducibility was better than 5% (RSD).

  6. Development of a dose assay for a Clostridium difficile vaccine using a tandem ion exchange high performance liquid chromatography method.

    Science.gov (United States)

    Wang, Feng; Ha, Sha; Rustandi, Richard R

    2017-05-19

    Clostridium difficile is a gram-positive intestine bacterium that causes a severe diarrhea and could eventually be lethal. The main virulence factor is related to the release of two major exotoxins, toxin A (TcdA) and toxin B (TcdB). Recent C. difficile-associated disease (CDAD) outbreaks have been caused by hypervirulent strains which secrete an additional binary toxin (CDTa/CDTb). Vaccination against these toxins is considered the best way to combat the CDAD. Recently, a novel tetravalent C. difficile vaccine candidate containing all four toxins produced from a baculovirus expression system has been developed. A dose assay to release this tetravalent C. difficile vaccine was developed using tandem ion-exchange HPLC chromatography. A sequential weak cation exchange (carboxyl group) and weak anion exchange (tertiary amine group) columns were employed. The four C. difficile vaccine antigen pIs range from 4.4 to 8.6. The final optimized separation employs salt gradient elution at two different pHs. The standard analytical parameters such as LOD, LOQ, linearity, accuracy, precision and repeatability were evaluated for this method and it was deemed acceptable as a quantitative assay for vaccine release. Furthermore, the developed method was utilized for monitoring the stability of the tetravalent C. difficile vaccine in final container. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Target identification of volatile metabolites to allow the differentiation of lactic acid bacteria by gas chromatography-ion mobility spectrometry.

    Science.gov (United States)

    Gallegos, Janneth; Arce, Cristina; Jordano, Rafael; Arce, Lourdes; Medina, Luis M

    2017-04-01

    The purpose of this work was to study the potential of gas chromatography-ion mobility spectrometry (GC-IMS) to differentiate lactic acid bacteria (LAB) through target identification and fingerprints of volatile metabolites. The LAB selected were used as reference strains for their influence in the flavour of cheese. The four strains of LAB can be distinguished by the fingerprints generated by the volatile organic compounds (VOCs) emitted. 2-butanone, 2-pentanone, 2-heptanone and 3-methyl-1-butanol were identified as relevant VOCs for Lactobacillus casei and Lactobacillus paracasei subsp. paracasei. 2-Butanone and 3-methyl-1-butanol were identified in Lactococcus lactis subsp. lactis and Lactococcus cremoris subsp. cremoris. The IMS signals monitoring during a 24-30h period showed the growth of the LAB in vitro. The results demonstrated that GC-IMS is a useful technology for bacteria recognition and also for screening the aromatic potential of new isolates of LAB. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Evaluation of liquid chromatography-ion trap-time of flight hybrid mass spectrometry on the quantitative analysis for ginsenosides.

    Science.gov (United States)

    Xing, Lu; Xie, Lin; Liang, Yan; Xing, Rong; Rao, Tai; Zhou, Lijun; Wang, Qian; Fu, Hanxu; Ye, Wei; Wang, Guangji

    2014-07-01

    It is ideal and desirable for a single instrument to meet the requirement of both qualitative and quantitative analysis of complicated components in pharmacokinetic research for herbal medicine. Liquid chromatography combined with hybrid ion trap and time-of-flight mass spectrometry (LCMS-IT-TOF) was recently confirmed as a very powerful tool for the qualitative analysis of both target and nontarget components in herbal medicines. The present study was designed to investigate the feasibility of LCMS-IT-TOF on quantitative analysis of ginsenosides in biological matrices. A simple liquid-liquid extraction procedure was followed by injection of the extracts onto a C₁₈ column with gradient elution and detection based on LCMS-IT-TOF system in negative scan mode. The developed method was validated with respect to the limit of quantification, linear dynamic range, precision, accuracy, matrix effects and stabilities. All the results suggested that the presently developed method was sufficiently sensitive and robust enough to simultaneously monitor 15 ginsenosides with diverse properties and a large range of concentration differences. Therefore, this method would be expected to be highly useful for comprehensive studies of ginsenosides in complicated matrix. Copyright © 2014 John Wiley & Sons, Ltd.

  9. [Determination of iodine and its species in plant samples using ion chromatography-inductively coupled plasma mass spectrometry].

    Science.gov (United States)

    Lin, Li; Chen, Guang; Chen, Yuhong

    2011-07-01

    A method was established for the determination of iodine and its species in plant samples using ion chromatography-inductively coupled plasma mass spectrometry (IC-ICP/ MS). Alkaline extraction and IC-ICP/MS were applied as the sample pre-treatment method and the detection technique respectively, for iodate and iodide determination. Moreover, high-temperature pyrolysis absorption was adopted as the pre-treatment method for total iodine analysis, which finally converted all the iodine species into iodide and measured the iodide by IC-ICP/MS. The recoveries of iodine for alkaline extraction and high-temperature pyrolysis absorption were 89.6%-97.5% and 95.2%-111.2%, respectively. The results were satisfactory. The detection limit of iodine was 0.010 mg/kg. The iodine and its speciation contents in several kinds of plant samples such as seaweeds, kelp, cabbage, tea leaf and spinach were investigated. It was shown that the iodine in seaweeds mainly existed as organic iodine; while the ones in kelp, cabbage, tea leaf and spinach mainly existed as inorganic iodine.

  10. Microscopic insight into role of protein flexibility during ion exchange chromatography by nuclear magnetic resonance and quartz crystal microbalance approaches.

    Science.gov (United States)

    Hao, Dongxia; Ge, Jia; Huang, Yongdong; Zhao, Lan; Ma, Guanghui; Su, Zhiguo

    2016-03-18

    Driven by the prevalent use of ion exchange chromatography (IEC) for polishing therapeutic proteins, many rules have been formulated to summarize the different dependencies between chromatographic data and various operational parameters of interest based on statically determined interactions. However, the effects of the unfolding of protein structures and conformational stability are not as well understood. This study focuses on how the flexibility of proteins perturbs retention behavior at the molecular scale using microscopic characterization approaches, including hydrogen-deuterium (H/D) exchange detected by NMR and a quartz crystal microbalance (QCM). The results showed that a series of chromatographic retention parameters depended significantly on the adiabatic compressibility and structural flexibility of the protein. That is, softer proteins with higher flexibility tended to have longer retention times and stronger affinities on SP Sepharose adsorbents. Tracing the underlying molecular mechanism using NMR and QCM indicated that an easily unfolded flexible protein with a more compact adsorption layer might contribute to the longer retention time on adsorbents. The use of NMR and QCM provided a previously unreported approach for elucidating the effect of protein structural flexibility on binding in IEC systems. Copyright © 2016. Published by Elsevier B.V.

  11. DETERMINATION OF FREE CATECHOLAMINES IN URINE BY TANDEM AFFINITY/ION-PAIR CHROMATOGRAPHY AND FLOW INJECTION ANALYSIS

    Science.gov (United States)

    Thomas, David H.; Taylor, Jay D.; Barnaby, Omar S.; Hage, David S.

    2008-01-01

    Background A system was developed for the simultaneous measurement in urine of free catecholamines (i.e., dopamine, norepinephrine, epinephrine) and creatinine (i.e., an indicator of urine output and volume). This method was based on the use of tandem affinity/ion-pair HPLC and flow injection analysis. Methods The free catecholamines were extracted directly from urine by using an on-line phenylboronic acid affinity column. The extracted solutes were then separated and measured by ion-pair chromatography followed by amperometric detection. Creatinine was measured by an on-line flow injection analysis system based on the Jaffe reaction, which analyzed creatinine as it eluted non-retained from the phenylboronic acid column. Results Various factors were considered in the design and optimization of the phenylboronic acid column, the tandem affinity/ion-pair HPLC columns and the flow injection analysis system. The total analysis time for the final combined system was approximately 16 min per injection at 1 ml/min. This method was found to have good agreement with the expected results for control urine samples. The limits of detection for 20 μl samples (S/N = 3.0) were 1.8, 1.0 and 4.3 μg/l for norepinephrine, epinephrine and dopamine, respectively, while the limit of detection of creatinine was 5.0 mg/l. The linear response of this method extended over a 450 to 930-fold range in concentration for the catecholamines and covered the range of clinical interest. The within-day precision of this method was ±2.0−2.7%. Conclusions The ability of this method to simultaneously monitor both creatinine and other analytes makes this HPLC/FIA system an attractive method for use in monitoring urinary compounds. With this approach it was possible to provide fast results for small volumes of random urine samples that were collected as part of a psychological study. The same method could also be utilized with 12 or 24 h urine specimens. PMID:18773884

  12. MWCNTs based high sensitive lateral flow strip biosensor for rapid determination of aqueous mercury ions.

    Science.gov (United States)

    Yao, Li; Teng, Jun; Zhu, Mengya; Zheng, Lei; Zhong, Youhao; Liu, Guodong; Xue, Feng; Chen, Wei

    2016-11-15

    Here, we describe a disposable multi-walled carbon nanotubes (MWCNTs) labeled nucleic acid lateral flow strip biosensor for rapid and sensitive detection of aqueous mercury ions (Hg(2+)). Unlike the conventional colloidal gold nanoparticle based strip biosensors, the carboxylated MWCNTs were selected as the labeling substrate because of its high specific surface area for immobilization of recognition probes, improved stability and enhanced detection sensitivity of the strip biosensor. Combining the sandwich-type of T-Hg(2+)-T recognition mechanism with the optical properties of MWCNTs on lateral flow strip, optical black bands were observed on the lateral flow strips. Parameters (such as membrane category, the MWCNTs concentration, the amount of MWCNT-DNA probe, and the volume of the test probe) that govern the sensitivity and reproducibility of the sensor were optimized. The response of the optimized biosensor was highly linear over the range of 0.05-1ppb target Hg(2+), and the detection threshold was estimated at 0.05 ppb within a 15-min assay time. The sensitivity was 10-fold higher than the conventional colloidal gold based strip biosensor. More importantly, the stability of the sensor was also greatly improved with the usage of MWCNTs as the labeling. Crown Copyright © 2016. Published by Elsevier B.V. All rights reserved.

  13. An improved method for direct estimation of free cyanide in drinking water by Ion Chromatography-Pulsed Amperometry Detection (IC-PAD) on gold working electrode.

    Science.gov (United States)

    Kumar Meher, Alok; Labhsetwar, Nitin; Bansiwal, Amit

    2018-02-01

    In the present work a fast, reliable and safe Ion Exchange Chromatography-Pulsed Amperometry Detection (IC-PAD) method for direct determination of free cyanide in drinking water has been reported. To the best of our knowledge for the first time we are reporting the application of Gold working electrode for detection of free cyanide in a chromatography system. The system shows a wide linear range up to 8000µg/L. The electrode was found to have improved sensitivity and selectivity in the presence of interfering ions. The detection limit of the system was calculated to be 2µg/L. Long term evaluation of the electrode was found to be stable. Reproducible results were obtained from analysis of drinking water samples with recoveries of 98.3-101.2% and Relative Standard Deviations (RSD) of analysis of free cyanide in drinking water. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Method for the Determination of Ammonia in Mainstream Cigarette Smoke Using Ion Chromatography.

    Directory of Open Access Journals (Sweden)

    Christina Vaughan Watson

    Full Text Available Ammonia in mainstream smoke is present in both the particulate and vapor phases. The presence of ammonia in the cigarette filler material and smoke is of significance because of the potential role ammonia could have in raising the "smoke pH." An increased smoke pH could shift a fraction of total nicotine to free-base nicotine, which is reportedly more rapidly absorbed by the smoker. Methods measuring ammonia in smoke typically employ acid filled impingers to trap the smoke. We developed a fast, reliable method to measure ammonia in mainstream smoke without the use of costly and time consuming impingers to examine differences in ammonia delivery. The method uses both a Cambridge filter pad and a Tedlar bag to capture particulate and vapor phases of the smoke. We quantified ammonia levels in the mainstream smoke of 50 cigarette brands from 5 manufacturers. Ammonia levels ranged from approximately 1μg to 23μg per cigarette for ISO smoking conditions and 38μg to 67μg per cigarette for Canadian intense smoking conditions and statistically significance differences were observed between brands and manufacturers. Our findings suggest that ammonia levels vary by brand and are higher under Canadian intense smoking conditions.

  15. Mixed-bed ion exchange chromatography employing a salt-free pH gradient for improved sensitivity and compatibility in MudPIT.

    Science.gov (United States)

    Mommen, Geert P M; Meiring, Hugo D; Heck, Albert J R; de Jong, Ad P J M

    2013-07-16

    In proteomics, comprehensive analysis of peptides mixtures necessitates multiple dimensions of separation prior to mass spectrometry analysis to reduce sample complexity and increase the dynamic range of analysis. The main goal of this work was to improve the performance of (online) multidimensional protein identification technology (MudPIT) in terms of sensitivity, compatibility and recovery. The method employs weak anion and strong cation mixed-bed ion exchange chromatography (ACE) in the first separation dimension and reversed phase chromatography (RP) in the second separation dimension (Motoyama et.al. Anal. Chem 2007, 79, 3623-34.). We demonstrated that the chromatographic behavior of peptides in ACE chromatography depends on both the WAX/SCX mixing ratio as the ionic strength of the mobile phase system. This property allowed us to replace the conventional salt gradient by a (discontinuous) salt-free, pH gradient. First dimensional separation of peptides was accomplished with mixtures of aqueous formic acid and dimethylsulfoxide with increasing concentrations. The overall performance of this mobile phase system was found comparable to ammonium acetate buffers in application to ACE chromatography, but clearly outperformed strong cation exchange for use in first dimensional peptide separation. The dramatically improved compatibility between (salt-free) ion exchange chromatography and reversed phase chromatography-mass spectrometry allowed us to downscale the dimensions of the RP analytical column down to 25 μm i.d. for an additional 2- to 3-fold improvement in performance compared to current technology. The achieved levels of sensitivity, orthogonality, and compatibility demonstrates the potential of salt-free ACE MudPIT for the ultrasensitive, multidimensional analysis of very modest amounts of sample material.

  16. Determination of Co(II) in plant tissue by microwave digestion and ion chromatography coupled with luminol/perborate or luminol/percarbonate chemiluminescence detection.

    Science.gov (United States)

    Murillo Pulgarín, José A; García Bermejo, Luisa F; Carrasquero Durán, Armando

    2011-01-01

    The cobalt is an essential element for leguminous plants but may be harmful for other species; for that reason determination of Co(II) is very important for the management of polluted areas and for discover plants with capacity for the hyperaccumulation of heavy metals, which has produced a growing necessity of fast, sensitive and selective analytical techniques. To develop an analytical procedure for the determination of cobalt in plant tissue by coupling the ionic chromatography to the luminol-based chemiluminescence detection. The sample was digested in a mixture of concentrated nitric acid and hydrogen peroxide, using an microwave oven to dissolve the Co(II). The solution containing Co(II) ions was injected to an ionic chromatograph using oxalic acid as the eluent. The detection was based on the catalytic effect of Co(II) on the luminol chemiluminescence using perborate or percarbonate as oxidants. Experimental variables, such as concentrations, pH, flow rates and acid digestion conditions were optimised. Well-resolved chromatographic peaks were obtained. The height and area showed linear dependences with the Co(II) concentration, which were used to quantify the heavy metal, with recoveries up to 95%. The microwave irradiation (60  s) was sufficient for the complete mineralisation of 200  mg of sample, employing 2  mL of the acid mixture. The method was free from the interferences, requiring less than 12 minutes to complete the analysis. The method was simple and rapid for the determination of cobalt in plant tissue with detection limits comparable to those obtained with more sophisticated and expensive analytical equipment. Copyright © 2010 John Wiley & Sons, Ltd.

  17. Naturally occurring glucosinolates in plant extracts of rocket salad (Eruca sativa L.) identified by liquid chromatography coupled with negative ion electrospray ionization and quadrupole ion-trap mass spectrometry.

    Science.gov (United States)

    Cataldi, Tommaso R I; Rubino, Alessandra; Lelario, Filomena; Bufo, Sabino A

    2007-01-01

    A method for the comprehensive profiling of intact glucosinolates (GLSs), major and minor, occurring in leaves and seeds of rocket salad (Eruca sativa L.) is presented using optimized reversed-phase liquid chromatography (RP-LC) with electrospray ionization (ESI) ion trap mass spectrometry (ITMS). ESI-ITMS in the negative mode was confirmed to be very suitable to analyze these compounds in crude extracts. After extraction from the plant material with methanol/water (70:30 v/v) at 70 degrees C, the analytes of interest were separated on a C18 column using an eluent acidified with formic acid (0.1%) and modified with acetonitrile. All the GLSs found in leaves of rocket salad gave good signals corresponding to the deprotonated precursor ion, [M-H]-. Although the mass spectra also exhibited an analytically important non-covalent adduct ion at [2M-H]-, the structures of glucosinolates were confirmed by extensive sequential MS analysis, thereby substantially improving the identification of unknown compounds. The results obtained not only revealed in leaves of E. sativa at least twelve species of GLSs including seven aliphatic compounds (glucoraphanin with [M-H]- at m/z ratio of 436, glucoerucin at m/z 420, 4-mercaptobutyl-GLS at m/z 406, progoitrin/epiprogoitrin at m/z 388, sinigrin at m/z 358, 4-methylpentyl- and n-hexyl-GLS at m/z 402) and three indole glucosinolates (i.e., three N-heterocyclic compounds: 4-hydroxyglucobrassicin and 5-hydroxyglucobrassicin at m/z 463, and 4-methoxy-glucobrassicin at m/z 477), but also two structurally related compounds containing one intermolecular disulfide linkage (4-(beta-D-glucopyranosyldisulfanyl)butyl-GLS at m/z 600 and a dimeric 4-mercaptobutyl-GLS at m/z 811). This latter symmetric disulfide was previously considered as an artefact formed during extraction of GLSs from vegetative tissues. Glucosinolates were detected in the leaves with a wide range of contents (10-200 micromol/g) and a great variation in the composition. Only

  18. Towards Liquid Chromatography Time-Scale Peptide Sequencing and Characterization of Post-Translational Modifications in the Negative-Ion Mode Using Electron Detachment Dissociation Tandem Mass Spectrometry

    DEFF Research Database (Denmark)

    Kjeldsen, Frank; Hørning, Ole B; Jensen, Søren S

    2008-01-01

    Electron detachment dissociation (EDD) of peptide poly-anions is gentle towards post-translational modifications (PTMs) and produces predictable and interpretable fragment ion types (a., x ions). However, EDD is considered an inefficient fragmentation technique and has not yet been implemented...... in large-scale peptide characterization strategies. We successfully increased the EDD fragmentation efficiency (up to 9%), and demonstrate for the first time the utility of EDD-MS/MS in liquid chromatography time-scale experiments. Peptides and phosphopeptides were analyzed in both positive- and negative...

  19. Technical note: removal of metal ion inhibition encountered during DNA extraction and amplification of copper-preserved archaeological bone using size exclusion chromatography.

    Science.gov (United States)

    Matheson, Carney D; Marion, Travis E; Hayter, Shana; Esau, Neal; Fratpietro, Renee; Vernon, Kim K

    2009-10-01

    A novel technique for the removal of metal ions inhibiting DNA extraction and PCR of archaeological bone extracts is presented using size exclusion chromatography. Two case studies, involving copper inhibition, demonstrate the effective removal of metal ion inhibition. Light microscopy, SEM, elemental analysis, and genetic analysis were used to demonstrate the effective removal of metal ions from samples that previously exhibited molecular inhibition. This research identifies that copper can cause inhibition of DNA polymerase during DNA amplification. The use of size exclusion chromatography as an additional purification step before DNA amplification from degraded bone samples successfully removes metal ions and other inhibitors, for the analysis of archaeological bone. The biochemistry of inhibition is explored through chemical and enzymatic extraction methodology on archaeological material. We demonstrate a simple purification technique that provides a high yield of purified DNA (>95%) that can be used to address most types of inhibition commonly associated with the analysis of degraded archaeological and forensic samples. We present a new opportunity for the molecular analysis of archaeological samples preserved in the presence of metal ions, such as copper, which have previously yielded no DNA results.

  20. Nano-Engineered Materials for Rapid Rechargeable Space Rated Advanced Li-Ion Batteries Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Lithium-ion (Li-ion) batteries are attractive candidates for use as power sources in aerospace applications because they have high specific energy, energy density...

  1. Quantitation of 11 alkylamines in atmospheric samples: separating structural isomers by ion chromatography

    Science.gov (United States)

    Place, Bryan K.; Quilty, Aleya T.; Di Lorenzo, Robert A.; Ziegler, Susan E.; VandenBoer, Trevor C.

    2017-03-01

    Amines are important drivers in particle formation and growth, which have implications for Earth's climate. In this work, we developed an ion chromatographic (IC) method using sample cation-exchange preconcentration for separating and quantifying the nine most abundant atmospheric alkylamines (monomethylamine (MMAH+), dimethylamine (DMAH+), trimethylamine (TMAH+), monoethylamine (MEAH+), diethylamine (DEAH+), triethylamine (TEAH+), monopropylamine (MPAH+), isomonopropylamine (iMPAH+), and monobutylamine (MBAH+)) and two alkyl diamines (1, 4-diaminobutane (DABH+) and 1, 5-diaminopentane (DAPH+)). Further, the developed method separates the suite of amines from five common atmospheric inorganic cations (Na+, NH4+, K+, Mg2+, Ca2+). All 16 cations are greater than 95 % baseline resolved and elute in a runtime of 35 min. This paper describes the first successful separation of DEAH+ and TMAH+ by IC and achieves separation between three sets of structural isomers, providing specificity not possible by mass spectrometry. The method detection limits for the alkylamines are in the picogram per injection range and the method precision (±1σ) analyzed over 3 months was within 16 % for all the cations. The performance of the IC method for atmospheric application was tested with biomass-burning (BB) particle extracts collected from two forest fire plumes in Canada. In extracts of a size-resolved BB sample from an aged plume, we detected and quantified MMAH+, DMAH+, TMAH+, MEAH+, DEAH+, and TEAH+ in the presence of Na+, NH4+, and K+ at molar ratios of amine to inorganic cation ranging from 1 : 2 to 1 : 1000. Quantities of DEAH+ and DMAH+ of 0.2-200 and 3-1200 ng m-3, respectively, were present in the extracts and an unprecedented amine-to-ammonium molar ratio greater than 1 was observed in particles with diameters spanning 56-180 nm. Extracts of respirable fine-mode particles (PM2. 5) from a summer forest fire in British Columbia in 2015 were found to contain iMPAH+, TMAH+, DEAH

  2. Determination of soluble bromine in an extra-high-pressure mercury discharge lamp by sodium hydroxide decomposition-suppressed ion chromatography.

    Science.gov (United States)

    Mitsumata, Hiroshi; Mori, Toshio; Maeda, Tatsuo; Kita, Yoshiyuki; Kohatsu, Osamu

    2006-02-01

    We have established a simple method for assaying the quantity of soluble bromine in the discharge tubes of an extra-high-pressure mercury discharge lamp. Each discharge tube is destroyed in 5 ml of 10 mM sodium hydroxide, and the recovered sodium hydroxide solution is analyzed by suppressed-ion chromatography using gradient elution. We have clarified that this method can assay less than 1 microg of soluble bromine in a discharge tube.

  3. Qualitative and quantitative characterization of plasma proteins when incorporating traveling wave ion mobility into a liquid chromatography-mass spectrometry workflow for biomarker discovery: use of product ion quantitation as an alternative data analysis tool for label free quantitation.

    Science.gov (United States)

    Daly, Charlotte E; Ng, Leong L; Hakimi, Amirmansoor; Willingale, Richard; Jones, Donald J L

    2014-02-18

    Discovery of protein biomarkers in clinical samples necessitates significant prefractionation prior to liquid chromatography-mass spectrometry (LC-MS) analysis. Integrating traveling wave ion mobility spectrometry (TWIMS) enables in-line gas phase separation which when coupled with nanoflow liquid chromatography and data independent acquisition tandem mass spectrometry, confers significant advantages to the discovery of protein biomarkers by improving separation and inherent sensitivity. Incorporation of TWIMS leads to a packet of concentrated ions which ultimately provides a significant improvement in sensitivity. As a consequence of ion packeting, when present at high concentrations, accurate quantitation of proteins can be affected due to detector saturation effects. Human plasma was analyzed in triplicate using liquid-chromatography data independent acquisition mass spectrometry (LC-DIA-MS) and using liquid-chromatography ion-mobility data independent acquisition mass spectrometry (LC-IM-DIA-MS). The inclusion of TWIMS was assessed for the effect on sample throughput, data integrity, confidence of protein and peptide identification, and dynamic range. The number of identified proteins is significantly increased by an average of 84% while both the precursor and product mass accuracies are maintained between the modalities. Sample dynamic range is also maintained while quantitation is achieved for all but the most abundant proteins by incorporating a novel data interpretation method that allows accurate quantitation to occur. This additional separation is all achieved within a workflow with no discernible deleterious effect on throughput. Consequently, TWIMS greatly enhances proteome coverage and can be reliably used for quantification when using an alternative product ion quantification strategy. Using TWIMS in biomarker discovery in human plasma is thus recommended.

  4. Determination of calcium dobesilate in human plasma using ion-pairing extraction and high-performance liquid chromatography.

    Science.gov (United States)

    Róna, K; Ary, K

    2001-05-05

    A rapid, simple reversed-phase high-performance liquid chromatographic method with ultraviolet absorbance detection has been developed for the determination of calcium dobesilate in human plasma. Sample processing is based on an ion-pairing extraction with tetra-n-butylammonium hydroxide as cationic pairing ion and dichloromethane. Separation of the investigated calcium dobesilate and 2,4-dihydroxybenzoic acid as internal standard was achieved on a Discovery RP-Amide C16 analytical column with 50 mM, pH 2.5, potassium dihydrogenphosphate buffer-acetonitrile (75:25, v/v) mobile phase. The wavelength was set at 305 nm. The limit of quantitation is 100 ng/ml and the calibration curve is linear up to 50 microg/ml. Within-day and between-day precision expressed as the relative standard deviation is about 10% and the accuracy of the determination did not deviate from 100% by more than +/-10%. The developed method was found to be suitable for application in human bioequivalence studies.

  5. Evaluation of the Ion Torrent PGM sequencing workflow for the routine rapid detection of BRCA1 and BRCA2 germline mutations.

    Science.gov (United States)

    Zanella, Isabella; Merola, Francesca; Biasiotto, Giorgio; Archetti, Silvana; Spinelli, Elide; Di Lorenzo, Diego

    2017-04-01

    Conventional methods used to identify BRCA1/2 germline mutations in hereditary cancers are time-consuming and expensive, due to the large size of the genes. The recent introduction of next generation sequencing (NGS) benchtop platforms is a great promise, which is rapidly revolutionizing genetic screening in diagnostic and clinical applications. We recently transferred our methodology for routine BRCA1/2 mutation screening (denaturing High Performance Liquid Chromatography plus Sanger sequencing) to the Ion Torrent PGM platform with the Ion Ampliseq BRCA1 and BRCA2 panel and tested the performance of the system. We first validated the NGS approach in a cohort of 33 patients who had previously undergone genetic diagnosis in our laboratory by conventional methods. Then, we tested 29 newly diagnosed and uncharacterized patients by NGS, and Sanger sequencing was used to confirm results from the NGS platform. In the validation cohort, all previously identified single nucleotide variants, insertions and deletions (also composed of multiple bases and within complex homopolymeric stretches) were identified by NGS in their correct zygosity status except for variants in a complex multinucleotide region within intron 7 of BRCA1 gene. NGS approach was further able to identify previously undetected variants. In the prospective cohort, almost all (99.3%) called variants were confirmed by Sanger. In both cohorts, in addition to the false positive (31) and false negative (110) results in the intron 7 of BRCA1 gene, the NGS method detected 10 false positives, that were solved by Sanger. The Ion Torrent PGM NGS approach in BRCA1/2 germline mutation identification is highly sensitive, easy to use, faster and cheaper than traditional approaches. Therefore, according to other recently published works, we highly recommend this system for routine diagnostic testing on BRCA1/2 genes, along with Sanger confirmation of the called variants, and support the usefulness of the approach also in

  6. Two-dimensional ion chromatography for the separation of ionic organophosphates generated in thermally decomposed lithium hexafluorophosphate-based lithium ion battery electrolytes.

    Science.gov (United States)

    Kraft, Vadim; Grützke, Martin; Weber, Waldemar; Menzel, Jennifer; Wiemers-Meyer, Simon; Winter, Martin; Nowak, Sascha

    2015-08-28

    A two-dimensional ion chromatography (IC/IC) technique with heart-cutting mode for the separation of ionic organophosphates was developed. These analytes are generated during thermal degradation of three different commercially available Selectilyte™ lithium ion battery electrolytes. The composition of the investigated electrolytes is based on 1M lithium hexafluorophosphate (LiPF6) dissolved in ethylene carbonate/dimethyl carbonate (50:50wt%, LP30), ethylene carbonate/diethyl carbonate (50:50wt%, LP40) and ethylene carbonate/ethyl methyl carbonate (50:50wt%, LP50). The organophosphates were pre-separated from PF6(-) anion on the low capacity A Supp 4 column, which was eluted with a gradient step containing acetonitrile. The fraction containing analytes was retarded on a pre-concentration column and after that transferred to the high capacity columns, where the separation was performed isocratically. Different stationary phases and eluents were applied on the 2nd dimension for the investigation of retention times, whereas the highly promising results were obtained with a high capacitive A Supp 10 column. The organophosphates generated in LP30 and LP40 electrolytes could be separated by application of an aqueous NaOH eluent providing fast analysis time within 35min. For the separation of the organophosphates of LP50 electrolyte due to its complexity a NaOH eluent containing a mixture of methanol/H2O was necessary. In addition, the developed two dimensional IC method was hyphenated to an inductively coupled plasma mass spectrometer (ICP-MS) using aqueous NaOH without organic modifiers. This proof of principle measurement was carried out for future quantitative investigation regarding the concentration of the ionic organophosphates. Furthermore, the chemical stability of several ionic organophosphates in water and acetonitrile at room temperature over a period of 10h was investigated. In both solvents no decomposition of the investigated analytes was observed and

  7. Comparison of Gas Chromatography-Mass Spectrometry and Gas Chromatography-Tandem Mass Spectrometry with Electron Ionization and Negative-Ion Chemical Ionization for Analyses of Pesticides at Trace Levels in Atmospheric Samples

    Directory of Open Access Journals (Sweden)

    Renata Raina

    2008-01-01

    Full Text Available A comparison of detection limits of gas chromatography-mass spectrometry (GC-MS in selected ion monitoring (SIM with gas chromatography-tandem mass spectrometry (GC-MS/MS in selected reaction monitoring (SRM mode with both electron ionization (EI and negative-ion chemical ionization (NCI are presented for over 50 pesticides ranging from organochlorines (OCs, organophosphorus pesticides (OPs and pre-emergent herbicides used in the Canadian prairies (triallate, trifluralin, ethalfluralin. The developed GC-EI/SIM, GC-NCI/SIM, and GC-NCI/SRM are suitable for the determination of pesticides in air sample extracts at concentrations <100 pg µL−1 (<100 pg m−3 in air. No one method could be used to analyze the range of pre-emergent herbicides, OPs, and OCs investigated. In general GC-NCI/SIM provided the lowest method detection limits (MDLs commonly 2.5–10 pg µL−1 along with best confirmation (<25% RSD of ion ratio, while GC-NCI/SRM is recommended for use where added selectivity or confirmation is required (such as parathion-ethyl, tokuthion, carbofenothion. GC-EI/SRM at concentration <100 pg µL−1 was not suitable for most pesticides. GC-EI/SIM was more prone to interference issues than NCI methods, but gave good sensitivity (MDLs 1–10 pg µL−1 for pesticides with poor NCI response (OPs: sulfotep, phorate, aspon, ethion, and OCs: alachlor, aldrin, perthane, and DDE, DDD, DDT.

  8. Rapid and sensitive analysis of phthalate metabolites, bisphenol A, and endogenous steroid hormones in human urine by mixed-mode solid-phase extraction, dansylation, and ultra-performance liquid chromatography coupled with triple quadrupole mass spectrometry.

    Science.gov (United States)

    Wang, He-xing; Wang, Bin; Zhou, Ying; Jiang, Qing-wu

    2013-05-01

    Steroid hormone levels in human urine are convenient and sensitive indicators for the impact of phthalates and/or bisphenol A (BPA) exposure on the human steroid hormone endocrine system. In this study, a rapid and sensitive method for determination of 14 phthalate metabolites, BPA, and ten endogenous steroid hormones in urine was developed and validated on the basis of ultra-performance liquid chromatography coupled with electrospray ionization triple quadrupole mass spectrometry. The optimized mixed-mode solid phase-extraction separated the weakly acidic or neutral BPA and steroid hormones from acidic phthalate metabolites in urine: the former were determined in positive ion mode with a methanol/water mobile phase containing 10 mM ammonium formate; the latter were determined in negative ion mode with a acetonitrile/water mobile phase containing 0.1 % acetic acid, which significantly alleviated matrix effects for the analysis of BPA and steroid hormones. Dansylation of estrogens and BPA realized simultaneous and sensitive analysis of the endogenous steroid hormones and BPA in a single chromatographic run. The limits of detection were less than 0.84 ng/mL for phthalate metabolites and less than 0.22 ng/mL for endogenous steroid hormones and BPA. This proposed method had satisfactory precision and accuracy, and was successfully applied to the analyses of human urine samples. This method could be valuable when investigating the associations among endocrine-disrupting chemicals, endogenous steroid hormones, and relevant adverse outcomes in epidemiological studies.

  9. Instrumentation pour la spectroscopie laser sur faisceau d'ions rapides

    Science.gov (United States)

    Bazin, Marc

    Devant l'emergence des technologies exploitant l'infiniment petit, la spectroscopie atomique et moleculaire devient de plus en plus incontournable pour comprendre precisement les mecanismes quantiques impliques dans l'interaction des molecules. C'est le cas notamment de la nanotechnologie, de la dynamique reactionnelle des gaz a effet de serre ou simplement de l'identification des molecules constituant certains objets de l'astrophysique. Bien qu'un travail considerable soit deja accompli pour comprendre la dissociation ou la formation des molecules simples, il reste a vaincre la complexite des mecanismes impliques lorsque les molecules possedent plus de trois noyaux. Parmi les rares techniques de spectroscopie a tres haute resolution (jusqu'a la structure hyperfine), la spectroscopie laser sur faisceaux d'ions rapides est une methode experimentale eprouvee depuis trois decennies environ. Cette methode spectroscopique fournit des resultats comptant parmi les meilleurs pour obtenir des constantes moleculaires precises et permettre la reduction du spectre moleculaire. Une particularite remarquable de notre instrument est la possibilite d'enregistrer le signal de fragmentation moleculaire par laser via les etats de predissociation de la molecule etudiee. Notre contribution a ete d'ameliorer et de moderniser l'equipement existant. Nous avons augmente la resolution spectrale de notre instrument. Nous avons atteint notre principal objectif, a savoir, la possibilite d'acquerir des spectres selon deux modes : par detection du signal synchronisee sur le faisceau laser module en frequence ou par detection du signal directement par comptage. Cette derniere methode est une premiere sur ce type d'instrument et son principal interet a ete d'obtenir une meilleure mesure de l'elargissement de raie. Nous sommes parvenus a mettre clairement en evidence l'elargissement de raie avec la puissance laser en utilisant la methode de detection par comptage direct. La fluorescence induite par

  10. A simplified method for rapid quantification of intracellular nucleoside triphosphates by one-dimensional thin-layer chromatography

    DEFF Research Database (Denmark)

    Jendresen, Christian Bille; Kilstrup, Mogens; Martinussen, Jan

    2011-01-01

    -pyrophosphate (PRPP), and inorganic pyrophosphate (PPi) in cell extracts. The method uses one-dimensional thin-layer chromatography (TLC) and radiolabeled biological samples. Nucleotides are resolved at the level of ionic charge in an optimized acidic ammonium formate and chloride solvent, permitting...

  11. Chemical profiling of Re-Du-Ning injection by ultra-performance liquid chromatography coupled with electrospray ionization tandem quadrupole time-of-flight mass spectrometry through the screening of diagnostic Ions in MS(E mode.

    Directory of Open Access Journals (Sweden)

    Haibo Li

    Full Text Available The broad applications and mechanism explorations of traditional Chinese medicine prescriptions (TCMPs require a clear understanding of TCMP chemical constituents. In the present study, we describe an efficient and universally applicable analytical approach based on ultra-performance liquid chromatography coupled to electrospray ionization tandem quadrupole time-of-flight mass spectrometry (UPLC-ESI-Q/TOF-MS with the MS(E ((E denotes collision energy data acquisition mode, which allowed the rapid separation and reliable determination of TCMP chemical constituents. By monitoring diagnostic ions in the high energy function of MS(E, target peaks of analogous compounds in TCMPs could be rapidly screened and identified. "Re-Du-Ning" injection (RDN, a eutherapeutic traditional Chinese medicine injection (TCMI that has been widely used to reduce fever caused by viral infections in clinical practice, was studied as an example. In total, 90 compounds, including five new iridoids and one new sesquiterpene, were identified or tentatively characterized by accurate mass measurements within 5 ppm error. This analysis was accompanied by MS fragmentation and reference standard comparison analyses. Furthermore, the herbal sources of these compounds were unambiguously confirmed by comparing the extracted ion chromatograms (EICs of RDN and ingredient herbal extracts. Our work provides a certain foundation for further studies of RDN. Moreover, the analytical approach developed herein has proven to be generally applicable for profiling the chemical constituents in TCMPs and other complicated mixtures.

  12. Characterization of Mycobacterium paratuberculosis by gas-liquid and thin-layer chromatography and rapid demonstration of mycobactin dependence using radiometric methods

    Energy Technology Data Exchange (ETDEWEB)

    Damato, J.J.; Knisley, C.; Collins, M.T.

    1987-12-01

    Thirty-six Mycobacterium paratuberculosis isolates of bovine, caprine, and ovine origins were evaluated by using gas-liquid chromatography (GLC), thin-layer chromatography (TLC), and BACTEC 7H12 Middlebrook TB medium in an effort to more rapidly differentiate this group of organisms from other mycobacteria. Bacterial suspensions (0.1 ml) were inoculated by syringe into 7H12 broth containing 2 micrograms of mycobactin P per ml and control broth without mycobactin P. Cultures were incubated at 37/sup 0/C and read daily with a BACTEC Model 301. After 8 days of incubation, the growth index readings for the test broths containing mycobactin P were twice those of the control broths without mycobactin P. Sixty-five isolates of mycobacteria other than M. paratuberculosis were also examined. No difference was noted between the growth index readings of control and mycobactin-containing broths. Except for Mycobacterium avium-Mycobacterium intracellulare, TLC studies differentiated M. paratuberculosis from the other mycobacterial species tested. The GLC data reveal that all M. paratuberculosis isolates had a distinctive peak (14A) which was not found among M. avium-M. intracellulare complex organisms. These data indicate that 7H12 radiometric broth was able to rapidly demonstrate the mycobactin dependence of M. paratuberculosis and GLC and TLC procedures were capable of rapidly differentiating this organism from the other mycobacteria studied.

  13. Analysis of perchlorate in foods and beverages by ion chromatography coupled with tandem mass spectrometry (IC-ESI-MS/MS)

    Energy Technology Data Exchange (ETDEWEB)

    El Aribi, Houssain [Applied Biosystems/MDS Sciex, 71 Four Valley Drive, Concord, Ont., L4K 4V8 (Canada)]. E-mail: houssain.aribi@sciex.com; Le Blanc, Yves J.C. [Applied Biosystems/MDS Sciex, 71 Four Valley Drive, Concord, Ont., L4K 4V8 (Canada); Antonsen, Stephen [Dionex Canada Ltd., 1540 Cornwall Road, Oakville, Ont., L6J 7W5 (Canada); Sakuma, Takeo [Applied Biosystems/MDS Sciex, 71 Four Valley Drive, Concord, Ont., L4K 4V8 (Canada)

    2006-05-10

    A new IC-ESI-MS/MS method, with simple sample preparation procedure, has been developed for quantification and confirmation of perchlorate (ClO{sub 4} {sup -}) anions in water, fresh and canned food, wine and beer samples at low part-per-trillion (ng l{sup -1}) levels. To the best of our knowledge, this is the first time an analytical method is used for determination of perchlorate in wine and beer samples. The IC-ESI-MS/MS instrumentation consisted of an ICS-2500 ion chromatography (IC) system coupled to either an API 2000{sup TM} or an API 3200{sup TM} mass spectrometer. The IC-ESI-MS/MS system was optimized to monitor two pairs of precursor and fragment ion transitions, i.e., multiple reaction monitoring (MRM). All samples had oxygen-18 isotope labeled perchlorate internal standard (ISTD) added prior to extraction. Chlorine isotope ratio ({sup 35}Cl/{sup 37}Cl) was used as a confirmation tool. The transition of {sup 35}Cl{sup 16}O{sub 4} {sup -} (m/z 98.9) into {sup 35}Cl{sup 16}O{sub 3} {sup -} (m/z 82.9) was monitored for quantifying the main analyte; the transition of {sup 37}Cl{sup 16}O{sub 4} {sup -} (m/z 100.9) into {sup 37}Cl{sup 16}O{sub 3} {sup -} (m/z 84.9) was monitored for examining a proper isotopic abundance ratio of {sup 35}Cl/{sup 37}Cl; and the transition of {sup 35}Cl{sup 18}O{sub 4} {sup -} (m/z 107.0) into {sup 35}Cl{sup 18}O{sub 3} {sup -} (m/z 89.0) was monitored for quantifying the internal standard. The minimum detection limit (MDL) for this method in de-ionized water is 5 ng l{sup -1} (ppt) using the API 2000{sup TM} mass spectrometer and 0.5 ng l{sup -1} using the API 3200{sup TM} mass spectrometer. Over 350 food and beverage samples were analyzed mostly in triplicate. Except for four, all samples were found to contain measurable amounts of perchlorate. The levels found ranged from 5 ng l{sup -1} to 463.5 {+-} 6.36 {mu}g kg{sup -1} using MRM 98.9 {sup {yields}} 82.9 and 100 {mu}l injection.

  14. Fast filtration sampling protocol for mammalian suspension cells tailored for phosphometabolome profiling by capillary ion chromatography - tandem mass spectrometry.

    Science.gov (United States)

    Kvitvang, Hans F N; Bruheim, Per

    2015-08-15

    Capillary ion chromatography (capIC) is the premium separation technology for low molecular phosphometabolites and nucleotides in biological extracts. Removal of excessive amounts of salt during sample preparation stages is a prerequisite to enable high quality capIC separation in combination with reproducible and sensitive MS detection. Existing sampling protocols for mammalian cells used for GC-MS and LC-MS metabolic profiling can therefore not be directly applied to capIC separations. Here, the development of a fast filtration sampling protocol for mammalian suspension cells tailored for quantitative profiling of the phosphometabolome on capIC-MS/MS is presented. The whole procedure from sampling the culture to transfer of filter to quenching and extraction solution takes less than 10s. To prevent leakage it is critical that a low vacuum pressure is applied, and satisfactorily reproducibility was only obtained by usage of a vacuum pressure controlling device. A vacuum of 60mbar was optimal for filtration of multiple myeloma Jjn-3 cell cultures through 5μm polyvinylidene (PVDF) filters. A quick deionized water (DI-water) rinse step prior to extraction was tested, and significantly higher metabolite yields were obtained during capIC-MS/MS analyses in this extract compared to extracts prepared by saline and reduced saline (25%) washing steps only. In addition, chromatographic performance was dramatically improved. Thus, it was verified that a quick DI-water rinse is tolerated by the cells and can be included as the final stage during filtration. Over 30 metabolites were quantitated in JJN-3 cell extracts by using the optimized sampling protocol with subsequent capIC-MS/MS analysis, and up to 2 million cells can be used in a single filtration step for the chosen filter and vacuum pressure. The technical set-up is also highly advantageous for microbial metabolome filtration protocols after optimization of vacuum pressure and washing solutions, and the reduced salt

  15. pH-gradient ion-exchange microbial cell chromatography as a simple method for microbial separation.

    Science.gov (United States)

    Aoi, Yoshiteru; Kaneko, Yuji; Tsuneda, Satoshi

    2017-04-01

    Selective separation of specific microbial types from a heterogeneous microbial population, such as an environmental microbial community, is an important process for microbial research and biotechnological industries. In the present study, pH-gradient ion-exchange microbial cell chromatography (PIE-MCC) was developed as a new method for microbial separation. The proposed method enables target microorganisms to be separated from a microbial community based on differences in microbial surface characteristics, because these characteristics, such as the ζ (zeta)-potential, vary among microbial cells. PIE-MCC was conducted by controlling the adhesion and detachment of microbial cells to and from the carrier surface by manipulating the pH of the running buffer. As a proof of concept, microbial cell separation via PIE-MCC was demonstrated using pure-cultured strains, model mixtures of two different pure-cultured strains, and an environmental sample targeting uncultivated microorganisms; i.e., each pure-cultured strain showed unique chromatograms; specific single species were separated from the model mixture; and a specific, uncultivated target was separated from the environmental sample. The ζ-potential of several tested strains suggested that not only electrostatic interactions, but also other factors affected microbial adhesion to the carrier surface. The newly developed method has several potential advantages compared with other techniques, not only in terms of its microbial separation capability, but also in terms of its simplicity and ability to be scaled up. Thus, the method has the potential to be widely used for a variety of purposes in the microbiology and biotechnology fields. Copyright © 2016 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  16. Analysis of haloacetic acids, bromate, and dalapon in natural waters by ion chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Wu, Shimin; Anumol, Tarun; Gandhi, Jay; Snyder, Shane A

    2017-03-03

    The addition of oxidants for disinfecting water can lead to the formation of potentially carcinogenic compounds referred to as disinfection byproducts (DBPs). Haloacetic acids (HAAs) are one of the most widely detected DBPs in US water utilities and some of them are regulated by the US Environmental Protection Agency (USEPA). The present study developed a method to analyze all the compounds in the USEPA method 557 (nine HAAs, bromate and dalapon) plus four potentially more toxic iodinated HAAs in water by coupling ion chromatography with tandem mass spectrometry (IC-MS/MS). This aqueous direct injection method has significant advantages over traditional GC methods, which require a derivatization and sample extraction that are laborious, time-consuming, and can negatively impact reproducibility. The method developed in this study requires half the time of the current USEPA method 557 on IC-MS/MS while including more compounds and achieving sub-μg/L level method detection limits (MDLs) for all 15 target analytes. The single laboratory lowest concentration minimum reporting level (LCMRL) has also been determined in reagent water, which ranged from 0.011 to 0.62μg/L for the analytes. The mean recoveries of the analytes during matrix spike recovery tests were 77-125% in finished drinking water and 81-112% in surface water. This method was then applied to untreated, chlorinated, and chloraminated groundwater and surface water samples. Bromate and 9 HAAs were detected at different levels in some of these samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Plasma homocysteine measurement with ion exchange chromatography (Jeol Aminotac 500): a comparison with the Abbott IMx assay.

    Science.gov (United States)

    Pernet, Pascal; Cuzon, Gaëlle; Lim, Soo-Kyung; Labau, Nicole; Laghzal, Aïcha; Vaubourdolle, Michel

    2006-01-01

    We evaluated ion exchange chromatography (IEC) on the Jeol Aminotac 500 analyzer for total homocysteine (tHcy) determination and compared it with an immunoassay method using fluorescence polarization on an Abbott IMx analyzer. IEC method validation (linearity, limit of detection, precision, interference) was made according to the French Biology Society guidelines (Société Française de Biologie Clinique). Moreover, during a 2-month period, 55 plasma samples from patients scheduled for routine tHCy measurement were assayed by both methods for determining correlation. The IEC method was found linear up to at least 190 micromol/l, and the limit of detection was 1.6 micromol/l. Precision was studied with 3 controls at 6, 15 and 30 micromol/l. Intra-assay coefficients of variation (n = 14) were 8.3, 3.1 and 2.3%, respectively, and inter-assay coefficients of variation (n = 15) were 9.6, 5.1 and 4.9%, respectively. No interference was found with other sulfur-containing amino acids (methionine, cysteine). An excellent agreement was found between IEC and fluorescence polarization (Deming regression; y = 0.99x - 1.23; r = 0.97; p < 0.001). The IEC method for tHcy measurement shows adequate precision and correlates highly with the IMx assay. The IEC method is more time-consuming but less expensive in reagent cost and allows simultaneous determination of plasma methionine concentration which may help to explain the underlying mechanism responsible for hyperhomocysteinemia. (c) 2006 S. Karger AG, Basel

  18. Recovery of infective virus particles in ion-exchange and hydrophobic interaction monolith chromatography is influenced by particle charge and total-to-infective particle ratio.

    Science.gov (United States)

    Sviben, Dora; Forcic, Dubravko; Ivancic-Jelecki, Jelena; Halassy, Beata; Brgles, Marija

    2017-06-01

    Viral particles are used in medical applications as vaccines or gene therapy vectors. In order to obtain product of high purity, potency and safety for medical use purification of virus particles is a prerequisite, and chromatography is gaining increased attention to meet this aim. Here, we report on the use of ion-exchange and hydrophobic interaction chromatography on monolithic columns for purification of mumps virus (MuV) and measles virus (MeV). Efficiency of the process was monitored by quantification of infective virus particles (by 50% cell culture infective dose assay) and total virus particles, and monitoring of their size (by Nanoparticle Tracking Analysis). Ion-exchange chromatography was shown to be inefficient for MuV and best results for MeV were obtained on QA column with recovery around 17%. Purification of MuV and MeV by hydrophobic interaction chromatography resulted in recoveries around 60%. Results showed that columns with small channels (d=1.4μm) are not suitable for MuV and MeV, although their size is below 400nm, whereas columns with large channels (6μm) showed to be efficient and recoveries independent on the flow rate up to 10mL/min. Heterogeneity of the virus suspension and its interday variability mostly regarding total-to-infective particle ratio was observed. Interestingly, a trend in recovery depending on the day of the harvest was also observed for both viruses, and it correlated with the total-to-infective particle ratio, indicating influence of the virus sample composition on the chromatography results. Copyright © 2017. Published by Elsevier B.V.

  19. Dynamic solid phase microextraction for sampling of airborne sarin with gas chromatography-mass spectrometry for rapid field detection and quantification.

    Science.gov (United States)

    Hook, Gary L; Jackson Lepage, Carmela; Miller, Stephen I; Smith, Philip A

    2004-08-01

    A portable dynamic air sampler and solid phase microextraction were used to simultaneously detect, identify, and quantify airborne sarin with immediate analysis of samples using a field portable gas chromatography-mass spectrometry system. A mathematical model was used with knowledge of the mass of sarin trapped, linear air velocity past the exposed sampling fiber, and sample duration allowing calculation of concentration estimates. For organizations with suitable field portable instrumentation, these methods are potentially useful for rapid onsite detection and quantification of high concern analytes, either through direct environmental sampling or through sampling of air collected in bags.

  20. Detection of Gelatin Adulteration in Traditional Chinese Medicine: Analysis of Deer-Horn Glue by Rapid-Resolution Liquid Chromatography-Triple Quadrupole Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Jia Chen

    2015-01-01

    Full Text Available Simultaneous identification of donkey-hide gelatin and bovine-hide gelatin in deer-horn glue was established by rapid-resolution liquid chromatography-triple quadrupole mass spectrometry. Water containing 1% NH4HCO3 was used for sample dissolution and trypsin was used for hydrolysis of the gelatins. After separation by a SB-C18 reversed-phase analytical column, collagen marker peptides were detected by mass spectrometry in positive electrospray ionization mode with multiple reaction monitoring. The method was specific, precise and reliable, and suitable for detection of adulterants derived from donkey-hide gelatin and bovine-hide gelatin in deer-horn glue.

  1. Validation of a pH gradient-based ion-exchange chromatography method for high-resolution monoclonal antibody charge variant separations.

    Science.gov (United States)

    Rea, Jennifer C; Moreno, G Tony; Lou, Yun; Farnan, Dell

    2011-01-25

    Ion-exchange chromatography is widely used for profiling the charge heterogeneity of proteins, including monoclonal antibodies. Despite good resolving power and robustness, ionic strength-based ion-exchange separations are product-specific and time-consuming to develop. We have previously reported a novel pH-based separation of proteins by cation exchange chromatography that was multi-product, high-resolution, and robust against variations in sample matrix salt concentration and pH. In this study, a pH gradient-based separation method using cation exchange chromatography was evaluated in a mock validation. This method was shown to be robust for monoclonal antibodies and suitable for its intended purpose of charge heterogeneity analysis. Simple mixtures of defined buffer components were used to generate the pH gradients that separated closely related antibody species. Validation characteristics, such as precision and linearity, were evaluated. Robustness to changes in protein load, buffer pH and column oven temperature was demonstrated. The stability-indicating capability of this method was determined using thermally stressed antibody samples. In addition, intermediate precision was demonstrated using multiple instruments, multiple analysts, multiple column lots, and different column manufacturers. Finally, the precision for this method was compared to conventional ion-exchange chromatography and imaged capillary isoelectric focusing. These results demonstrate the superior precision and robustness of this multi-product method, which can be used for the high-throughput evaluation of in-process and final product samples. Copyright © 2010 Elsevier B.V. All rights reserved.

  2. Rapid and sensitive method for quantification of gestodene in human plasma as the oxime derivative by liquid chromatography-tandem mass spectrometry (LC-MS/MS) and its application to bioequivalence study.

    Science.gov (United States)

    Saxena, Ashish; Gupta, Arun; Kasibhatta, Ravisekhar; Bob, Manoj; Kumar, V Praveen; Purwar, Bipin

    2014-01-15

    A rapid and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the estimation of gestodene in human plasma. Gestodene was extracted from human plasma by using solid-phase extraction technique. Gestodene D6 was used as the internal standard. An Acquity HSS-T3 column provided chromatographic separation of analytes followed by detection with mass spectrometry. The mass transition ion-pair was followed as m/z 326.2→124.1 for gestodene and m/z 332.3→129.1 for gestodene D6. The method involves a solid phase extraction from plasma, rapid derivatization with hydroxylamine to form oxime, simple gradient chromatographic conditions and mass spectrometric detection that enables detection at sub-picogram levels. The proposed method has been validated for a linear range of 50-11957pg/ml with a correlation coefficient≥0.9994. The intra-run and inter-run precision and accuracy were within 10%. The overall recoveries for gestodene and gestodene D6 were 62.02% and 67.57% respectively. The total run time was 4.0min. The developed method was applied for the determination of the pharmacokinetic parameters of gestodene following a single oral administration of a 2×0.06mg gestodene tablets in 10 healthy female volunteers. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. Multiwalled carbon nanotubes as a solid-phase extraction adsorbent for the determination of three barbiturates in pork by ion trap gas chromatography-tandem mass spectrometry (GC/MS/MS) following microwave assisted derivatization

    Energy Technology Data Exchange (ETDEWEB)

    Zhao Haixiang [College of Science, China Agricultural University, Beijing 100094 (China); Inspection Technology and Equipment Institute, Chinese Academy of Inspection and Quarantine, Beijing 100025 (China); Department of Basic Agricultural Science, Hebei North College, Zhangjiakou Hebei 075131 (China); Wang Liping [College of Science, China Agricultural University, Beijing 100094 (China); Qiu Yueming [Inspection Technology and Equipment Institute, Chinese Academy of Inspection and Quarantine, Beijing 100025 (China); Zhou Zhiqiang [College of Science, China Agricultural University, Beijing 100094 (China)]. E-mail: zqzhou@cau.edu.cn; Zhong Weike [Inspection Technology and Equipment Institute, Chinese Academy of Inspection and Quarantine, Beijing 100025 (China); Li Xiang [Inspection Technology and Equipment Institute, Chinese Academy of Inspection and Quarantine, Beijing 100025 (China)

    2007-03-14

    A new method was developed for the rapid screening and confirmation analysis of barbital, amobarbital and phenobarbital residues in pork by gas chromatography-tandem mass spectrometry (GC/MS/MS) with ion trap MSD. The residual barbiturates in pork were extracted by ultrasonic extraction, cleaned up on a multiwalled carbon nanotubes (MWCNTs) packed solid phase extraction (SPE) cartridge and applied acetone-ethyl acetate (3:7, v/v) mixture as eluting solvent and derivatized with CH{sub 3}I under microwave irradiation. The methylated barbiturates were separated on a TR-5MS capillary column and detected with an ion trap mass detector. Electron impact ion source (EI) operating MS/MS mode was adopted for identification and external standard method was employed for quantification. One precursor ion m/z 169 was selected for analysis of barbital and amobarbital and m/z 232 was selected for phenobarbital. The product ions were obtained under 1.0 V excitation voltage. Good linearities (linear coefficient R > 0.99) were obtained at the range of 0.5-50 {mu}g kg{sup -1}. Limit of detection (LOD) of barbital was 0.2 {mu}g kg{sup -1} and that of amobarbital and phenobarbital were both 0.1 {mu}g kg{sup -1} (S/N {>=} 3). Limit of quatification (LOQ) was 0.5 {mu}g kg{sup -1} for three barbiturates (S/N {>=} 10). Satisfying recoveries ranging from 75% to 96% of the three barbiturates spiked in pork were obtained, with relative standard deviations (R.S.D.) in the range of 2.1-7.8%.

  4. Rapid and accurate simultaneous determination of abamectin and ivermectin in bovine milk by high performance liquid chromatography with fluorescence detection

    OpenAIRE

    Kolberg, D. I. S.; Presta, M.A.; Wickert, C.; Adaime,M. B.; R. Zanella

    2009-01-01

    An analytical method using high performance liquid chromatography with fluorescence detection for the simultaneous determination of abamectin and ivermectin in bovine milk was developed and validated. The best recovery results were achieved by using acetonitrile for extraction of the compounds followed by solid phase extraction in cartridges containing C18 for the purification of the extract. Pre-column derivatization was accomplished with N-methylimidazole and trifluoroacetic anhydride. The ...

  5. Rapid determination of alpha tocopherol in olive oil adulterated with sunflower oil by reversed phase high-performance liquid chromatography

    OpenAIRE

    Bakre, S.M.; Gadmale, D. K.; Toche, R. B.; V. B. GAIKWAD

    2014-01-01

    A new method is developed to determine the presence of sunflower oil in olive oil. α-tocopherol is selected as discriminating parameter for detecting sunflower oil adulterant in olive oil. Admixtures of olive oil and sunflower oil (5 %, 10 %, 15 % and 20 % sunflower oil in olive oil) are prepared. These admixtures are analysed by reversed phase high pressure liquid chromatography coupled with fluorescence detector. The sample preparation does not require saponification or addition of antioxid...

  6. Mass accuracy improvement of reversed-phase liquid chromatography/electrospray ionization mass spectrometry based urinary metabolomic analysis by post-run calibration using sodium formate cluster ions.

    Science.gov (United States)

    Juo, Chiun-Gung; Chen, Chien-Lun; Lin, Shiang-Ting; Fu, Shu-Hsuan; Chen, Yi-Ting; Chang, Yu-Sun; Yu, Jau-Song

    2014-08-30

    Typically, a batch metabolomics analysis using liquid chromatography/electrospray ionization time-of-flight mass spectrometry (LC/ESI-TOF MS) takes 2 to 3 days. However, the mass accuracy - which has an important influence on metabolite identification - can drift by as much as about 17 ppm in such a time period. In an untargeted urinary metabolomics analysis by reversed-phase liquid chromatography (RPLC)/ESI-MS, the signals of sodium formate cluster ions were detected at the column-washing step. The cluster ions were used to calibrate the mass spectrometer for more accurate detection. The spectra were calibrated post-run by the sodium formate cluster ions, which were used as the internal standard, in order to improve the mass accuracy. In the analysis of urine samples, we calibrated the spectra acquired by the micrOTOF with the sodium cluster ions. In positive mode ESI, the average errors of these cluster ions were improved to ±0.48 ppm and in negative mode ESI, to ±0.94 ppm after calibration. The mass accuracy remained within ±0.01 ppm over the duration of 6.25 days. An error window of 4 ppm appears to be suitable for metabolite identification when using post-calibration. The results showed that sodium formate cluster ions could be utilized for the calibration of LC/ESI-TOF MS and the average instrumental errors could be maintained at low levels for long-term analyses. This method could be applied not only to urine sample, but also to low sodium samples, such as saliva, by dissolving the sample in 1 μM sodium formate solution. This method provides a good solution for accurate mass detection of metabolomic analysis. Copyright © 2014 John Wiley & Sons, Ltd.

  7. Rapid fabrication of microfluidic polymer electrolyte membrane fuel cell in PDMS by surface patterning of perfluorinated ion-exchange resin

    Energy Technology Data Exchange (ETDEWEB)

    Song, Yong-Ak; Han, Jongyoon [Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, 77 Massachusetts Ave., Cambridge, MA 02139 (United States); Department of Biological Engineering, Massachusetts Institute of Technology, 77 Massachusetts Ave., Cambridge, MA 02139 (United States); Batista, Candy [Roxbury Community College, 1234 Columbus Ave., Roxbury Crossing, MA 02120 (United States); Sarpeshkar, Rahul [Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, 77 Massachusetts Ave., Cambridge, MA 02139 (United States)

    2008-09-01

    In this paper we demonstrate a simple and rapid fabrication method for a microfluidic polymer electrolyte membrane (PEM) fuel cell using polydimethylsiloxane (PDMS), which has become the de facto standard material in BioMEMS. Instead of integrating a Nafion sheet film between two layers of a PDMS device in a traditional ''sandwich format,'' we pattern a perfluorinated ion-exchange resin such as a Nafion resin on a glass substrate using a reversibly bonded PDMS microchannel to generate an ion-selective membrane between the fuel-cell electrodes. After this patterning step, the assembly of the microfluidic fuel cell is accomplished by simple oxygen plasma bonding between the PDMS chip and the glass substrate. In an example implementation, the planar PEM microfluidic fuel cell generates an open circuit voltage of 600-800 mV and delivers a maximum current output of nearly 4 {mu}A. To enhance the power output of the fuel cell we utilize self-assembled colloidal arrays as a support matrix for the Nafion resin. Such arrays allow us to increase the thickness of the ion-selective membrane to 20 {mu}m and increase the current output by 166%. Our novel fabrication method enables rapid prototyping of microfluidic fuel cells to study various ion-exchange resins for the polymer electrolyte membrane. Our work will facilitate the development of miniature, implantable, on-chip power sources for biomedical applications. (author)

  8. A rapid and reliable procedure for extraction of cellular polyamines and inorganic ions from plant tissues

    Science.gov (United States)

    Rakesh Minocha; Walter C. Shortle; Stephanie L. Long; Subhash C. Minocha

    1994-01-01

    A fast and reliable method for the extraction of cellular polyamines and major inorganic ions (Ca, Mg, Mn, K, and P) from several plant tissues is described. The method involves repeated freezing and thawing of samples instead of homogenization. The efficiency of extraction of both the polyamines and inorganic ions by these two methods was compared for 10 different...

  9. Rapid Focused Ion Beam Milling Based Fabrication of Plasmonic Nanoparticles and Assemblies via "Sketch and Peel" Strategy.

    Science.gov (United States)

    Chen, Yiqin; Bi, Kaixi; Wang, Qianjin; Zheng, Mengjie; Liu, Qing; Han, Yunxin; Yang, Junbo; Chang, Shengli; Zhang, Guanhua; Duan, Huigao

    2016-12-27

    Focused ion beam (FIB) milling is a versatile maskless and resistless patterning technique and has been widely used for the fabrication of inverse plasmonic structures such as nanoholes and nanoslits for various applications. However, due to its subtractive milling nature, it is an impractical method to fabricate isolated plasmonic nanoparticles and assemblies which are more commonly adopted in applications. In this work, we propose and demonstrate an approach to reliably and rapidly define plasmonic nanoparticles and their assemblies using FIB milling via a simple "sketch and peel" strategy. Systematic experimental investigations and mechanism studies reveal that the high reliability of this fabrication approach is enabled by a conformally formed sidewall coating due to the ion-milling-induced redeposition. Particularly, we demonstrated that this strategy is also applicable to the state-of-the-art helium ion beam milling technology, with which high-fidelity plasmonic dimers with tiny gaps could be directly and rapidly prototyped. Because the proposed approach enables rapid and reliable patterning of arbitrary plasmonic nanostructures that are not feasible to fabricate via conventional FIB milling process, our work provides the FIB milling technology an additional nanopatterning capability and thus could greatly increase its popularity for utilization in fundamental research and device prototyping.

  10. Simultaneous ionization and analysis of 84 anabolic androgenic steroids in human urine using liquid chromatography-silver ion coordination ionspray/triple-quadrupole mass spectrometry.

    Science.gov (United States)

    Kim, So-Hee; Cha, Eun-Ju; Lee, Kang Mi; Kim, Ho Jun; Kwon, Oh-Seung; Lee, Jaeick

    2014-01-01

    Metal ion coordination ionspray (M(+) CIS) ionization is a powerful technique to enhance ionization efficiency and sensitivity. In this study, we developed and validated an analytical method for simultaneous ionization and analysis of 84 anabolic androgenic steroids (65 exogenous and 19 endogenous) using liquid chromatography-silver ion coordination ionspray/triple-quadrupole mass spectrometry (LC-Ag(+) CIS/MS/MS). The concentrations of silver ions and organic solvents have been optimized to increase the amount of silver ion coordinated complexes. A combination of 25 μM of silver ions and methanol showed the best sensitivity. The validation results showed the intra- (0.8-9.2%) and inter-day (2.5-14.9%) precisions, limits of detection (0.0005-5.0 ng/mL), and matrix effect (71.8-100.3%) for the screening analysis. No significant ion suppression was observed. In addition, this method was successfully applied to analysis of positive samples from suspected abusers and useful for the detection of the trace levels of anabolic steroids in human urine samples. Copyright © 2014 John Wiley & Sons, Ltd.

  11. PEG chain length impacts yield of solid-phase protein PEGylation and efficiency of PEGylated protein separation by ion-exchange chromatography: insights of mechanistic models.

    Science.gov (United States)

    Yoshimoto, Noriko; Isakari, Yu; Itoh, Daisuke; Yamamoto, Shuichi

    2013-07-01

    The mechanisms behind protein PEGylation are complex and dictated by the structure of the protein reactant. Hence, it is difficult to design a reaction process which can produce the desired PEGylated form at high yield. Likewise, efficient purification processes following protein PEGylation must be constructed on an ad hoc basis for each product. The retention and binding mechanisms driving electrostatic interaction-based chromatography (ion-exchange chromatography) of PEGylated proteins (randomly PEGylated lysozyme and mono-PEGylated bovine serum albumin) were investigated, based on our previously developed model Chem. Eng. Technol. 2005, 28, 1387-1393. PEGylation of each protein resulted in a shift to a smaller elution volume compared to the unmodified molecule, but did not affect the number of binding sites appreciably. The shift of the retention volume of PEGylated proteins correlated with the calculated thickness of PEG layer around the protein molecule. Random PEGylation was carried out on a column (solid-phase PEGylation) and the PEGylated proteins were separated on the same column. Solid-phase PEGylation inhibited the production of multi-PEGylated forms and resulted in a relatively low yield of selective mono-PEGylated form. Pore diffusion may play an important role in solid-phase PEGylation. These results suggest the possibility of a reaction and purification process development based on the mechanistic model for PEGylated proteins on ion exchange chromatography. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Rapid Screening of Multiclass Syrup Adulterants in Honey by Ultrahigh-Performance Liquid Chromatography/Quadrupole Time of Flight Mass Spectrometry.

    Science.gov (United States)

    Du, Bing; Wu, Liming; Xue, Xiaofeng; Chen, Lanzhen; Li, Yi; Zhao, Jing; Cao, Wei

    2015-07-29

    Honey adulteration with sugar syrups is a widespread problem. Several types of syrups have been used in honey adulteration, and there is no available method that can simultaneously detect all of these adulterants. In this study, we generated a small-scale database containing the specific chromatographic and mass spectrometry information on sugar syrup markers and developed a simple, rapid, and effective ultrahigh-performance liquid chromatography/quadrupole time-of-flight mass spectrometry (UHPLC/Q-TOF-MS) method for the detection of adulterated honey. Corn syrup, high-fructose corn syrup, inverted syrup, and rice syrup were used as honey adulterants; polysaccharides, difructose anhydrides, and 2-acetylfuran-3-glucopyranoside were used as detection markers. The presence of 10% sugar syrup in honey could be easily detected in <30 min using the developed method. The results revealed that UHPLC/Q-TOF-MS was simple and rapid.

  13. A simple and rapid method for high-resolution visualization of single-ion tracks

    Energy Technology Data Exchange (ETDEWEB)

    Omichi, Masaaki [Department of Applied Chemistry, Graduate School of Engineering, Osaka University, Osaka 565-0871 (Japan); Center for Collaborative Research, Anan National College of Technology, Anan, Tokushima 774-0017 (Japan); Choi, Wookjin; Sakamaki, Daisuke; Seki, Shu, E-mail: seki@chem.eng.osaka-u.ac.jp [Department of Applied Chemistry, Graduate School of Engineering, Osaka University, Osaka 565-0871 (Japan); Tsukuda, Satoshi [Institute of Multidisciplinary Research for Advanced Materials, Tohoku University, Sendai, Miyagi 980-8577 (Japan); Sugimoto, Masaki [Japan Atomic Energy Agency, Takasaki Advanced Radiation Research Institute, Gunma, Gunma 370-1292 (Japan)

    2014-11-15

    Prompt determination of spatial points of single-ion tracks plays a key role in high-energy particle induced-cancer therapy and gene/plant mutations. In this study, a simple method for the high-resolution visualization of single-ion tracks without etching was developed through the use of polyacrylic acid (PAA)-N, N’-methylene bisacrylamide (MBAAm) blend films. One of the steps of the proposed method includes exposure of the irradiated films to water vapor for several minutes. Water vapor was found to promote the cross-linking reaction of PAA and MBAAm to form a bulky cross-linked structure; the ion-track scars were detectable at a nanometer scale by atomic force microscopy. This study demonstrated that each scar is easily distinguishable, and the amount of generated radicals of the ion tracks can be estimated by measuring the height of the scars, even in highly dense ion tracks. This method is suitable for the visualization of the penumbra region in a single-ion track with a high spatial resolution of 50 nm, which is sufficiently small to confirm that a single ion hits a cell nucleus with a size ranging between 5 and 20 μm.

  14. A simple and rapid method for high-resolution visualization of single-ion tracks

    Directory of Open Access Journals (Sweden)

    Masaaki Omichi

    2014-11-01

    Full Text Available Prompt determination of spatial points of single-ion tracks plays a key role in high-energy particle induced-cancer therapy and gene/plant mutations. In this study, a simple method for the high-resolution visualization of single-ion tracks without etching was developed through the use of polyacrylic acid (PAA-N, N’-methylene bisacrylamide (MBAAm blend films. One of the steps of the proposed method includes exposure of the irradiated films to water vapor for several minutes. Water vapor was found to promote the cross-linking reaction of PAA and MBAAm to form a bulky cross-linked structure; the ion-track scars were detectable at a nanometer scale by atomic force microscopy. This study demonstrated that each scar is easily distinguishable, and the amount of generated radicals of the ion tracks can be estimated by measuring the height of the scars, even in highly dense ion tracks. This method is suitable for the visualization of the penumbra region in a single-ion track with a high spatial resolution of 50 nm, which is sufficiently small to confirm that a single ion hits a cell nucleus with a size ranging between 5 and 20 μm.

  15. QUANTITATIVE ION-PAIR EXTRACTION OF 4(5)-METHYLIMIDAZOLE FROM CARAMEL COLOR AND ITS DETERMINATION BY REVERSED-PHASE ION-PAIR LIQUID-CHROMATOGRAPHY

    DEFF Research Database (Denmark)

    Thomsen, Mohens; Willumsen, Dorthe

    1981-01-01

    A procedure for quantitative ion-pair extraction of 4(5)-methylimidazole from caramel colour using bis(2-ethylhexyl)phosphoric acid as ion-pairing agent has been developed. Furthermore, a reversed-phase ion-pair liquid chromatographic separation method has been established to analyse the content ...

  16. Wide-scope screening and quantification of 50 pesticides in wine by liquid chromatography/quadrupole time-of-flight mass spectrometry combined with liquid chromatography/quadrupole linear ion trap mass spectrometry.

    Science.gov (United States)

    He, Zeying; Xu, Yaping; Wang, Lu; Peng, Yi; Luo, Ming; Cheng, Haiyan; Liu, Xiaowei

    2016-04-01

    In this paper, a wide scope screening method of pesticides in wine was established using liquid chromatography/quadrupole time-of-flight mass spectrometry (LC-QTOF MS) and liquid chromatography/quadrupole linear ion trap mass spectrometry (LC-QqLIT MS). Information dependent acquisition (IDA) experiments are used to obtain both MS and MS/MS information for LC-QTOF MS analysis. For LC-QqLIT MS analysis, MS/MS spectra of target pesticides were simultaneously acquired using Enhanced Product Ion (EPI) mode at very low concentrations to increase the confidence in analytical results of multiple reaction monitoring (MRM) by library searching. Method validation was carried out using 50 pesticides commonly used in vineyards. The LOQs, linearity, repeatability were determined and good enough for quantification. The screening and quantification results obtained using LC-QTOF MS and LC-QqLIT MS were compared. Contaminants were screened against libraries containing over 2800 compounds based on accurate mass, isotopic patterns, and MS/MS spectra searching to extend the scope of this methodology to non-target screening. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Application of an online ion-chromatography-based instrument for gradient flux measurements of speciated nitrogen and sulfur

    Science.gov (United States)

    Rumsey, Ian C.; Walker, John T.

    2016-06-01

    The dry component of total nitrogen and sulfur atmospheric deposition remains uncertain. The lack of measurements of sufficient chemical speciation and temporal extent make it difficult to develop accurate mass budgets and sufficient process level detail is not available to improve current air-surface exchange models. Over the past decade, significant advances have been made in the development of continuous air sampling measurement techniques, resulting with instruments of sufficient sensitivity and temporal resolution to directly quantify air-surface exchange of nitrogen and sulfur compounds. However, their applicability is generally restricted to only one or a few of the compounds within the deposition budget. Here, the performance of the Monitor for AeRosols and GAses in ambient air (MARGA 2S), a commercially available online ion-chromatography-based analyzer is characterized for the first time as applied for air-surface exchange measurements of HNO3, NH3, NH4+, NO3-, SO2 and SO42-. Analytical accuracy and precision are assessed under field conditions. Chemical concentrations gradient precision are determined at the same sampling site. Flux uncertainty measured by the aerodynamic gradient method is determined for a representative 3-week period in fall 2012 over a grass field. Analytical precision and chemical concentration gradient precision were found to compare favorably in comparison to previous studies. During the 3-week period, percentages of hourly chemical concentration gradients greater than the corresponding chemical concentration gradient detection limit were 86, 42, 82, 73, 74 and 69 % for NH3, NH4+, HNO3, NO3-, SO2 and SO42-, respectively. As expected, percentages were lowest for aerosol species, owing to their relatively low deposition velocities and correspondingly smaller gradients relative to gas phase species. Relative hourly median flux uncertainties were 31, 121, 42, 43, 67 and 56 % for NH3, NH4+, HNO3, NO3-, SO2 and SO42-, respectively. Flux

  18. Determination of lipid-bound sulfate by ion chromatography and its application to quantification of sulfolipids from kidneys of various mammalian species.

    Science.gov (United States)

    Tadano-Aritomi, K; Hikita, T; Suzuki, A; Toyoda, H; Toida, T; Imanari, T; Ishizuka, I

    2001-10-01

    A variety of procedures have been developed for determining the sulfate ester content of various biomolecules. Ion chromatography (IC), that is, quantitation of ionic substances by ion conductimetry after separation by anion-exchange chromatography, has been increasingly utilized for the determination of inorganic sulfate in clinical and environmental samples. We adopted suppressed-mode IC to the determination of lipid- or glycolipid-bound sulfate released by acid hydrolysis and found that it has the advantage of increased precision for wide concentration ranges (30 pmol to approximately micromol) and lack of interference from other lipids. To minimize deterioration of the separation column, the lipophilic constituents in the acid hydrolysate were removed by a two-phase partition system of chloroform-methanol-water. The inorganic sulfate was quantitatively extracted into the aqueous phase by replacing water with an alkaline buffer. By this method, the concentration of sulfolipids was determined in the kidney of mammals with various body mass. Sulfolipids were more concentrated in the kidney of smaller animals, which have higher maximum urine concentrating activity per gram of body mass, supporting the hypothesis of the function of sulfolipids as an ion barrier on the luminal surface of renal tubules.

  19. [Multiresidue determination of organophosphorus pesticide residues in vegetables and fruit by gas chromatography-negative ion chemical ionization-mass spectrometry].

    Science.gov (United States)

    Lin, Zhuguang; Fan, Yulan; Ma, Yu; Jin, Zhen; Tan, Jun; Chen, Meiyu; Chen, Zhaobin; Tu, Fengzhang; Liu, Yong

    2006-05-01

    An analytical method of gas chromatography coupled with negative ion chemical ionization-mass spectrometry for simultaneous determination of nine organophosphorus pesticide residues in vegetables and fruit has been developed, and the negative ions structure and partition mechanism of the nine organophosphorus pesticides were interpreted. Meanwhile, the matrix effect for sample analysis was discussed, and matrix-matched calibration for quantification was introduced to reduce the matrix effect in this method. Pesticides were extracted from sample with ethyl acetate in an ultrasonic bath, then determined by gas chromatography-mass spectrometry operated in negative chemical ionization mode and quantified in selective ion monitoring mode, and ethion was used as an internal standard. The detection limits of the method were 0.12-1.0 microg/kg for the nine organophosphorus pesticides, and the relative coefficients were higher than 0.9993. A blank sample (tomato) was spiked at 100, 400, 800 microg/kg for each pesticide, and the recoveries were determined to be from 78% to 126% with relative standard deviations from 0.58% to 14.7% for the pesticides.

  20. Novel Anodes for Rapid Recharge High Energy Density Lithium-ion Batteries Project

    Data.gov (United States)

    National Aeronautics and Space Administration — TIAX proposes to develop as a novel negative electrode active material for rechargeable lithium-ion batteries. This material will fill the gap between the...

  1. Rapid liquid chromatography/tandem mass spectrometer (LCMS) method for clozapine and its metabolite N-desmethyl clozapine (norclozapine) in human serum.

    Science.gov (United States)

    Rao, L V; Snyder, M L; Vallaro, G M

    2009-01-01

    Clozapine is indicated for the treatment of schizophrenia and related psychotic disorders. Several methods have been developed for monitoring Clozapine levels; however, they possess limited specificity and are often laborious. This study describes a simple liquid chromatography/tandem mass spectrometer (LCMS) method in human serum. The ion transitions monitored were m/z 327, 270, 296 for Clozapine, m/z 313, 192, 227 for Norclozapine and m/z 328, 271 for Loxapine. The assay is linear (25-1000 ng/ml) and showed a good correlation (r=0.98) within the analytical range of 79-1210 ng/ml in human serum. This assay is highly specific and sensitive for the simultaneous measurements of Clozapine and Norclozapine. The simplification of this assay makes it ideal for high throughput analyses of the patient samples in a routine clinical laboratory staffed with general medical technologists.

  2. (S)-(-)-N-(pentafluorobenzylcarbamoyl)prolyl chloride: a chiral derivatisation reagent designed for gas chromatography/negative ion chemical ionisation mass spectrometry of amino compounds.

    Science.gov (United States)

    Leis, Hans J; Windischhofer, Werner

    2012-03-30

    The synthesis of a novel chiral derivatisation reagent, (S)-(-)-N-(pentafluorobenzylcarbamoyl)prolyl chloride is described which is preferably useful for negative-ion chemical ionisation mass spectrometry. Preparation of the reagent followed a general strategy used to prepare enantioselective reagents based on the N-substitution of L-proline. Pentafluorobenzyl chloroformate smoothly reacted with L-proline to give the desired derivatisation reagent after conversion into the acyl chloride. The product was sufficiently pure to be used in the following steps without any additional purification. The reagent was tested against selected chiral and non-chiral analytical targets. Chromatographic enantioseparation was at least equal to the commonly used (S)-(-)-N-(heptafluorobutyryl)prolyl derivatives. The derivatives exhibit excellent mass spectral properties under negative ion chemical ionisation, i.e. reduced fragmentation and thus high ion current for the targeted m/z during analysis. With electron ionisation, the fragmentation that occurs is mainly directed by the introduced group. Enantioseparation with gas chromatography/negative-ion chemical ionisation mass spectrometry of the derivatives was demonstrated for the enantiomers of amphetamine, α-aminocaprylic acid methyl ester and threo-methylphenidate. The new derivatisation reagent shows highly improved mass spectral properties for negative-ion chemical ionisation mass spectrometry and is thus suitable for sensitive chiral detection of amino compounds. The reagent extends the applicability of dissociative resonance electron capture using pentafluorobenzyl derivatives to chiral analysis. Copyright © 2012 John Wiley & Sons, Ltd.

  3. Determination of Hexavalent Chromium (Cr(VI Concentrations via Ion Chromatography and UV-Vis Spectrophotometry in Samples Collected from Nacogdoches Wastewater Treatment Plant, East Texas (USA

    Directory of Open Access Journals (Sweden)

    Kefa K. Onchoke

    2016-01-01

    Full Text Available The concentration of hexavalent chromium (Cr(VI, a toxic environmental pollutant and carcinogen, was determined in samples collected from Nacogdoches Wastewater Treatment Plant (NWWTP using ion chromatography and UV-visible spectrophotometry (IC, UV-Vis. On reaction with 1,5-diphenylcarbazide (DPC Cr+6 forms a 1,5-diphenylcarbazide-Cr(VI complex, which is then analyzed at 530 nm and 540 nm, respectively. Via ion chromatography Cr(VI concentrations were in the range of 0.00190±0.0020 and 0.0010±0.0006 ppm at the influent and effluent, respectively. With the use of standard addition wastewater samples were spiked with a 0.5 ppm Cr(VI standard of various amounts and subsequently analyzed with UV-Vis spectrophotometry. The spiked concentrations gave Cr(VI concentrations in the range of 0.0090±0.0060 ppm and 0.0040±0.0061 ppm at the influent and influent wastewater, respectively. The determined Cr(VI concentrations through the ion chromatography and UV-Vis spectrophotometry are below the maximum USEPA contaminant concentration of 0.1 ppm. From the analysis, the NWWTP efficiently removes Cr(VI before discharge into the environment through La Nana Creek. The removal efficiency for Cr(VI was determined to be ≥92.8% along the wastewater treatment stages from the influent (aeration stage to the effluent stages prior to discharge into the La Nana Creek.

  4. Development and validation of a rapid liquid chromatography isotope dilution tandem mass spectrometry (LC-IDMS/MS) method for serum creatinine.

    Science.gov (United States)

    Hétu, Pierre-Olivier; Gingras, Marie-Eve; Vinet, Bernard

    2010-09-01

    To develop an isotope dilution liquid chromatography tandem mass spectrometry (LC-IDMS/MS) method for the standardization of serum creatinine. Supernatants obtained by protein precipitation were injected into a LC-MS/MS. Chromatography was performed on a cation exchanger pre-column in normal phase isocratic mode. Creatinine and creatinine-D(3) were quantified using ion transitions of m/z 114-->44 and 117-->47, respectively. The method was calibrated with the NIST Standard Reference Material 914a and was found to be exact in analyzing the certified reference material SRM 967 from NIST (97.1+/-0.9% and 102.1+/-0.9% of target value for levels 1 and 2, respectively) and by calculating recuperation of spiked creatinine in 10 different patient samples (103.6+/-4.1%). Intra-assay imprecision was 0.9% at both 64.6 and 354 micromol/L creatinine, while inter-assay imprecisions were 1.9% and 1.8%. Absence of ion suppression was confirmed by spiking experiments. The method was shown to be free of carryover. A good correlation was obtained between the LC-MS/MS method and a Jaffe method run on an automated analyzer (r=0.999). We have developed a fast and simple method for the quantification of serum creatinine by isotope dilution tandem mass spectrometry (IDMS/MS) and we propose that this method can be used as a reference method by laboratories that wish to validate their serum creatinine automated assay. Published by Elsevier Inc.

  5. Dispersive solid phase extraction combined with ion-pair ultra high-performance liquid chromatography tandem mass spectrometry for quantification of nucleotides in Lactococcus lactis

    DEFF Research Database (Denmark)

    Magdenoska, Olivera; Martinussen, Jan; Thykær, Jette

    2013-01-01

    solid phase extraction with charcoal and subsequent analysis with ion-pair liquid chromatography coupled with electrospray ionization tandem mass spectrometry was established for quantification of intracellular pools of the 28 most important nucleotides. The method can handle extracts where cells leak...... was validated by determination of the recovery, matrix effects, accuracy, linearity, and limit of detection based on spiking of medium blank as well as standard addition to quenched Lactococcus lactis samples. For standard addition experiments, the isotope-labeled standards needed to be added in similar...

  6. Determinação de bromato em melhoradores de farinha por cromatografia de troca iônica com detecção espectrofotométrica Bromate determination in flour improvers by ion exchange chromatography with spectrophotometric detection

    Directory of Open Access Journals (Sweden)

    Rogério Marcos Dallago

    2005-08-01

    Full Text Available KBrO3 is registered by the FAO/OMS as a genotoxic and carcinogenic compound. In spite of this, KBrO3 is still employed by Brazilian bakeries. Nowadays ion exchange chromatography (IEC is the most rapid and trustful method for BrO3- analysis. When at high concentrations, chloride ions can interfere in the BrO3- analysis, if the detection is performed by electrical conductivity. On the other hand, spectrophotometric detection, presented here is based on the absorption of BrO3- in the ultraviolet region (210 - 230 nm where the absortion of chloride ions is very low, thus making possible the qualitative and quantitative analysis of BrO3- in flour improver samples.

  7. A rapid total reflection X-ray fluorescence protocol for micro analyses of ion profiles in Arabidopsis thaliana

    Science.gov (United States)

    Höhner, Ricarda; Tabatabaei, Samaneh; Kunz, Hans-Henning; Fittschen, Ursula

    2016-11-01

    The ion homeostasis of macro and micronutrients in plant cells and tissues is a fundamental requirement for vital biochemical pathways including photosynthesis. In nature, ion homeostasis is affected mainly by three processes: 1. Environmental stress factors, 2. Developmental effects, and 3. Loss or gain-of-function mutations in the plant genome. Here we present a rapid total reflection X-ray fluorescence (TXRF) protocol that allows for simultaneous quantification of several elements such as potassium (K), calcium (Ca), sulfur (S), manganese (Mn) and strontium (Sr) in Arabidopsis thaliana leaf specimens. Our procedure is cost-efficient and enables precise, robust and highly reproducible measurements on tissue samples as small as 0.3 mg dry weight. As shown here, we apply the TXRF procedure to detect accurately the early replacement of K by Na ions in leaves of plants exposed to soil salinity, a globally increasing abiotic stress factor. Furthermore, we were able to prove the existence of a leaf development-dependent ion gradient for K, Ca, and other divalent ions in A. thaliana; i.e. old leaves contain significantly lower K but higher Ca than young leaves. Lastly, we show that our procedure can be readily applied to reveal subtle differences in tissue-specific ion contents of plant mutants. We employed independent A. thaliana kea1kea2 loss-of-function mutants that lack KEA1 and KEA2, two highly active chloroplast K exchange proteins. We found significantly increased K levels specifically in kea1kea2 mutants, i.e. 55 mg ∗ g- 1 dry weight, compared to 40 mg ∗ g- 1 dry weight in wild type plants. The TXRF procedure can be supplemented with Flame atomic absorption (FAAS) and emission spectrometry (FAES) to expand the detection range to sodium (Na) and magnesium (Mg). Because of the small sample amounts required, this method is especially suited to probe individual leaves in single plants or even specific leaf areas. Therefore, TXRF represents a powerful method to

  8. Simultaneous determination of NH4+, NO2(-) and NO3(-) by ion-exclusion/anion-exchange chromatography on a strongly basic anion-exchange resin with basic eluent.

    Science.gov (United States)

    Mori, Masanobu; Hironaga, Takahiro; Itabashi, Hideyuki; Nakatani, Nobutake; Kozaki, Daisuke; Tanaka, Kazuhiko

    2012-04-01

    Ion-exclusion/anion-exchange chromatography (IEC/AEC) on a combination of a strongly basic anion-exchange resin in the OH(-)-form with basic eluent has been developed. The separation mechanism is based on the ion-exclusion/penetration effect for cations and the anion-exchange effect for anions to anion-exchange resin phase. This system is useful for simultaneous separation and determination of ammonium ion (NH4+), nitrite ion (NO2(-)), and nitrate ion (NO3(-)) in water samples. The resolution of analyte ions can be manipulated by changing the concentration of base in eluent on a polystyrene-divinylbenzene based strongly basic anion-exchange resin column. In this study, several separation columns, which consisted of different particle sizes, different functional groups and different anion-exchange capacities, were compared. As the results, the separation column with the smaller anion-exchange capacity (TSKgel Super IC-Anion) showed well-resolved separation of cations and anions. In the optimization of the basic eluent, lithium hydroxide (LiOH) was used as the eluent and the optimal concentration was concluded to be 2 mmol/L, considering the resolution of analyte ions and the whole retention times. In the optimal conditions, the relative standard deviations of the peak areas and the retention times of NH4+, NO2(-), and NO3(-) ranged 1.28% - 3.57% and 0.54% - 1.55%, respectively. The limits of detection at signal-to-noise of 3 were 4.10 micromol/L for NH4+, 1.87 micromol/L for NO2(-) and 2.83 micromol/L for NO3(-).

  9. Analysis and fragmentation mechanisms of hirsutinolide-type sesquiterpene lactones by ultra-high-performance liquid chromatography/electrospray ionization linear ion trap Orbitrap mass spectrometry.

    Science.gov (United States)

    Girardi, Cynthia; Jullian, Valérie; Haddad, Mohamed; Vansteelandt, Marieke; Cabanillas, Billy Joel; Kapanda, Coco N; Herent, Marie-France; Quetin-Leclercq, Joëlle; Fabre, Nicolas

    2016-03-15

    Hirsutinolide-type sesquiterpene lactones (SLs) are natural biologically active compounds mainly found in the genus Vernonia. Very few studies have been published about the fragmentation mechanisms of SLs generally and none about hirsutinolides, although they have drawn attention through their biological and taxonomical interest. This work aims to propose a mass spectrometry fragmentation pattern for hirsutinolides in order to detect and to identify them in a botanical extract. The fragmentation pathways of six pure hirsutinolides isolated from Pseudelephantopus spiralis were established by positive ion electrospray high-resolution linear ion trap Orbitrap tandem mass spectrometry (ESI(+)-HRMS(n) ). A resolutive, hyphenated ultra-high-performance liquid chromatography (UHPLC) coupled to diode array detection (DAD) and ESI(+)-HRMS(n) method was then implemented to separate and analyze them. The ionization behaviour and diagnostic product ions were investigated by both methods. The UHPLC/DAD-ESI-HRMS(n) method was applied for the dereplication of a plant extract. For the six standard compounds, the main fragmentation pattern consists first in the loss of the side chain in the C-8 position followed by the loss of the substituent in the C-13 position. UHPLC/HRMS analyses of hirsutinolides mainly produced sodiated molecules or [M+H-H2 O](+) ions. The high-abundance product ions at m/z 299 and 259 were established to be the characteristic diagnostic ions of the hirsutinolide core. The analysis of a P. spiralis extract further led to the identification of two putative hirsutinolides. The UHPLC/DAD-HRMS(n) method combining characteristic fragmentation patterns and the profiles of the product ions generated in the MS and MS/MS spectra is an effective technique for characterizing hirsutinolide-type SLs. Copyright © 2016 John Wiley & Sons, Ltd.

  10. Rapid determination of alpha tocopherol in olive oil adulterated with sunflower oil by reversed phase high-performance liquid chromatography.

    Science.gov (United States)

    Bakre, S M; Gadmale, D K; Toche, R B; Gaikwad, V B

    2015-05-01

    A new method is developed to determine the presence of sunflower oil in olive oil. α-tocopherol is selected as discriminating parameter for detecting sunflower oil adulterant in olive oil. Admixtures of olive oil and sunflower oil (5 %, 10 %, 15 % and 20 % sunflower oil in olive oil) are prepared. These admixtures are analysed by reversed phase high pressure liquid chromatography coupled with fluorescence detector. The sample preparation does not require saponification or addition of antioxidant. The chromatographic system consists of a C18 column with methanol: acetonitrile (50:50) mobile phase. Fluorescence detector excitation wavelength is set at 290 nm and emission wavelength is set at 330 nm. The α tocopherol concentration increases linearly in olive oil adulterated with sunflower oil. The method is simple, selective, sensitive and is precise (RSD = 2.65 %) for α tocopherol. The present method can precisely detect 5 % sunflower oil in olive oil.

  11. Rapid and reliable steroid hormone profiling in Tursiops truncatus blubber using liquid chromatography tandem mass spectrometry (LC-MS/MS).

    Science.gov (United States)

    Boggs, Ashley S P; Schock, Tracey B; Schwacke, Lori H; Galligan, Thomas M; Morey, Jeanine S; McFee, Wayne E; Kucklick, John R

    2017-08-01

    Monitoring of marine mammal steroid hormone status using matrices alternative to blood is desirable due to the ability to remotely collect samples, which minimizes stress to the animal. However, measurement techniques in alternative matrices such as blubber described to date are limited in the number and types of hormones measured. Therefore, a new method using bead homogenization to QuEChERS (Quick, Easy, Cheap, Effective, Rugged, and Safe) extraction, C18 post extraction cleanup and analysis by liquid chromatography tandem mass spectrometry (LC-MS/MS) was developed and applied to the measurement of hormone suites in bottlenose dolphin blubber. Validations were conducted in blubber from fresh dead stranded bottlenose dolphin. The final method consisting of two LC separations and garnet bead homogenization was tested for extraction efficiencies. Steroids were separated using a biphenyl column for reproductive hormones and C18 column for corticosteroids. Three hormones previously noted in blubber, testosterone, progesterone, and cortisol, were quantified in addition to previously unmeasured androstenedione, 17-hydroxyprogesterone, 11-deoxycortisol, 11-deoxycorticosterone, and cortisone in a single sample (0.4 g blubber). Extraction efficiencies of all hormones from blubber ranged from 84% to 112% and all RSDs were comparable to those reported using immunoassay methods (< 15%). The method was successfully applied to remote biopsied blubber samples to measure baseline hormone concentrations. Through this method, increased coverage of steroid hormone pathways from a single remotely collected sample potentially enhances the ability to interpret biological phenomena such as reproduction and stress in wild dolphin populations. Graphical abstract The steroid hormone profile is quantifiable from a single sample of bottlenose dolphin blubber using liquid chromatography tandem mass spectrometry. This profile can be applied to remotely collected dart biopsies and be used to

  12. Three-Dimensional Ionic Covalent Organic Frameworks for Rapid, Reversible, and Selective Ion Exchange.

    Science.gov (United States)

    Li, Zonglong; Li, Hui; Guan, Xinyu; Tang, Junjie; Yusran, Yusran; Li, Zhan; Xue, Ming; Fang, Qianrong; Yan, Yushan; Valtchev, Valentin; Qiu, Shilun

    2017-12-13

    Covalent organic frameworks (COFs) have emerged as functional materials for various potential applications. However, the availability of three-dimensional (3D) COFs is still limited, and nearly all of them exhibit neutral porous skeletons. Here we report a general strategy to design porous positively charged 3D ionic COFs by incorporation of cationic monomers in the framework. The obtained 3D COFs are built of 3-fold interpenetrated diamond net and show impressive surface area and CO2 uptakes. The ion-exchange ability of 3D ionic COFs has been highlighted by reversible removal of nuclear waste model ions and excellent size-selective capture for anionic pollutants. This research thereby provides a new perspective to explore 3D COFs as a versatile type of ion-exchange materials.

  13. Ion exchange chromatography of aluminum using 3-carboxy-2-naphthylamine-N,N-diacetic acid as a fluorescent post-column chelating reagent.

    Science.gov (United States)

    Miyahara, T; Kitamura, H; Narita, K; Toyo'oka, T

    1999-02-01

    Ion exchange chromatography of aluminum ion using 3-carboxy-2-naphthylamine-N,N-diacetic acid (CNDA) as a fluorescent post-column chelating reagent was studied. The solution containing ammonium chloride and hydrochloric acid was used for the eluent, and acetate buffer solution containing CNDA was used for the post column chelating reagent. The peak of aluminum was separated from that of calcium, magnesium and zinc, and the chromatogram was not affected by copper(II) and iron(III). The calibration curve gave linear plots with a range of 0.0027-0.54 ppm aluminum, the regression coefficient of correlation (r2) was 1.000, and the detection limit (S/N = 3) was 0.3 ppb, indicating that the method could determine aluminum with high sensitivity. It was demonstrated that CNDA is a useful metallofluorescent reagent for aluminum. This method has been successfully applied to the determination of aluminum in some tea drinks.

  14. Gas Chromatography/Atmospheric Pressure Chemical Ionization-Fourier Transform Ion Cyclotron Resonance Mass Spectrometry of Pyrolysis Oil from German Brown Coal

    Science.gov (United States)

    Zuber, Jan; Kroll, Marius M.; Rathsack, Philipp; Otto, Matthias

    2016-01-01

    Pyrolysis oil from the slow pyrolysis of German brown coal from Schöningen, obtained at a temperature of 500°C, was separated and analyzed using hyphenation of gas chromatography with an atmospheric pressure chemical ionization source operated in negative ion mode and Fourier transform ion cyclotron resonance mass spectrometry (GC-APCI-FT-ICR-MS). Development of this ultrahigh-resolving analysis method is described, that is, optimization of specific GC and APCI parameters and performed data processing. The advantages of GC-APCI-FT-ICR-MS hyphenation, for example, soft ionization, ultrahigh-resolving detection, and most important isomer separation, were demonstrated for the sample liquid. For instance, it was possible to separate and identify nine different propylphenol, ethylmethylphenol, and trimethylphenol isomers. Furthermore, homologous series of different acids, for example, alkyl and alkylene carboxylic acids, were verified, as well as homologous series of alkyl phenols, alkyl dihydroxy benzenes, and alkoxy alkyl phenols. PMID:27066076

  15. Peptide sequencing and characterization of post-translational modifications by enhanced ion-charging and liquid chromatography electron-transfer dissociation tandem mass spectrometry

    DEFF Research Database (Denmark)

    Kjeldsen, Frank; Giessing, Anders; Ingrell, Christian R

    2007-01-01

    We have tested the effect of m-nitrobenzyl alcohol (m-NBA) as a method to increase the average charge state of protonated gas-phase molecular ions generated by ESI from tryptic peptides and phosphopeptides. Various concentrations of m-NBA were added to the mobile phases of a liquid chromatography...... system coupled to an ESI tandem mass spectrometer. Addition of just 0.1% m-NBA changed the average charge state for the identified tryptic BSA peptides from 2.2+ to 2.6+. As a result, the predominant charge states for BSA peptides were changed from 2+ to > or =3+. To evaluate the benefits of peptide...... charge enhancement, the ETD fragmentation efficiency and Mascot peptide score were compared for BSA peptides in charge states 2+ and 3+. In all cases but one, triply charged peptides fragmented more efficiently than the analogues 2+ peptide ions. On average, triply charged peptides received a 68% higher...

  16. Ion chromatography electrospray ionization mass spectrometry method development and investigation of lithium hexafluorophosphate-based organic electrolytes and their thermal decomposition products.

    Science.gov (United States)

    Kraft, Vadim; Grützke, Martin; Weber, Waldemar; Winter, Martin; Nowak, Sascha

    2014-08-08

    A method based on the coupling of ion chromatography (IC) and electrospray ionization mass spectrometry (ESI-MS) for the separation and determination of thermal decomposition products of LiPF6-based organic electrolytes is presented. The utilized electrolytes, LP30 and LP50, are commercially available and consist of 1mol/l LiPF6 dissolved in ethylene carbonate/dimethyl carbonate and ethylene carbonate/ethyl methyl carbonate, respectively. For the separation method development three ion chromatographic columns with different capacity and stationary phase were used and compared. Besides the known hydrolysis products of lithium hexafluorophosphate, several new organophosphates were separated and identified with the developed IC-ESI-MS method during aging investigations of the electrolytes. The chemical structures were elucidated with IC-ESI-MS/MS. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Gas Chromatography/Atmospheric Pressure Chemical Ionization-Fourier Transform Ion Cyclotron Resonance Mass Spectrometry of Pyrolysis Oil from German Brown Coal

    Directory of Open Access Journals (Sweden)

    Jan Zuber

    2016-01-01

    Full Text Available Pyrolysis oil from the slow pyrolysis of German brown coal from Schöningen, obtained at a temperature of 500°C, was separated and analyzed using hyphenation of gas chromatography with an atmospheric pressure chemical ionization source operated in negative ion mode and Fourier transform ion cyclotron resonance mass spectrometry (GC-APCI-FT-ICR-MS. Development of this ultrahigh-resolving analysis method is described, that is, optimization of specific GC and APCI parameters and performed data processing. The advantages of GC-APCI-FT-ICR-MS hyphenation, for example, soft ionization, ultrahigh-resolving detection, and most important isomer separation, were demonstrated for the sample liquid. For instance, it was possible to separate and identify nine different propylphenol, ethylmethylphenol, and trimethylphenol isomers. Furthermore, homologous series of different acids, for example, alkyl and alkylene carboxylic acids, were verified, as well as homologous series of alkyl phenols, alkyl dihydroxy benzenes, and alkoxy alkyl phenols.

  18. Gas Chromatography/Atmospheric Pressure Chemical Ionization-Fourier Transform Ion Cyclotron Resonance Mass Spectrometry of Pyrolysis Oil from German Brown Coal.

    Science.gov (United States)

    Zuber, Jan; Kroll, Marius M; Rathsack, Philipp; Otto, Matthias

    2016-01-01

    Pyrolysis oil from the slow pyrolysis of German brown coal from Schöningen, obtained at a temperature of 500°C, was separated and analyzed using hyphenation of gas chromatography with an atmospheric pressure chemical ionization source operated in negative ion mode and Fourier transform ion cyclotron resonance mass spectrometry (GC-APCI-FT-ICR-MS). Development of this ultrahigh-resolving analysis method is described, that is, optimization of specific GC and APCI parameters and performed data processing. The advantages of GC-APCI-FT-ICR-MS hyphenation, for example, soft ionization, ultrahigh-resolving detection, and most important isomer separation, were demonstrated for the sample liquid. For instance, it was possible to separate and identify nine different propylphenol, ethylmethylphenol, and trimethylphenol isomers. Furthermore, homologous series of different acids, for example, alkyl and alkylene carboxylic acids, were verified, as well as homologous series of alkyl phenols, alkyl dihydroxy benzenes, and alkoxy alkyl phenols.

  19. Profiling of phenolic constituents in Polygonum multiflorum Thunb. by combination of ultra-high-pressure liquid chromatography with linear ion trap-Orbitrap mass spectrometry.

    Science.gov (United States)

    Qiu, Xiaohui; Zhang, Jing; Huang, Zhihai; Zhu, Dayuan; Xu, Wen

    2013-05-31

    A simple and effective method was developed for characterization of phenolic constituents in the roots of Polygonum multiflorum by combination of ultra-high-pressure liquid chromatography with linear ion trap-Orbitrap tandem mass spectrometry (UHPLC-LTQ-Orbitrap). Stilbenes, anthraquinones, tannins and naphthalenes were differentiated by diagnostic fragment ions with accurate mass measurements and characteristic fragmentation pathways. Based on the proposed strategy, fifty-nine constituents were characterized or tentatively identified, of which twenty-two constituents were the first to be reported in P. multiflorum and twelve compounds were characterized as potential new compounds. The identification and structure elucidation of these chemicals provided essential data for further phytochemical studies and quality control of P. multiflorum. The results also demonstrated that our novel method can be extended to screen and characterize other phenolic constituents and their metabolites in botanical extracts. Copyright © 2012 Elsevier B.V. All rights reserved.

  20. Determination of human insulin and its analogues in human blood using liquid chromatography coupled to ion mobility mass spectrometry (LC-IM-MS).

    Science.gov (United States)

    Thomas, Andreas; Schänzer, Wilhelm; Thevis, Mario

    2014-01-01

    The qualitative and quantitative determination of insulin from human blood samples is an emerging topic in doping controls as well as in other related disciplines (e.g. forensics). Beside the therapeutic use, insulin represents a prohibited, performance enhancing substance in sports drug testing. In both cases accurate, sensitive, specific, and unambiguous determination of the target peptide is of the utmost importance. The challenges concerning identifying insulins in blood by liquid chromatography coupled to ion mobility mass spectrometry (LC-IM-MS) are detecting the basal concentrations of approximately 0.2 ng/mL and covering the hyperinsulinaemic clamps at > 3 ng/mL simultaneously using up to 200 μL of plasma or serum. This is achieved by immunoaffinity purification of the insulins with magnetic beads and subsequent separation by micro-scale liquid chromatography coupled to ion mobility / high resolution mass spectrometry. The method includes human insulin as well as the synthetic or animal analogues insulin aspart, glulisine, glargine, detemir, lispro, bovine, and porcine insulin. The method validation shows reliable results considering specificity, limit of detection (0.2 ng/mL except for detemir: 0.8 ng/mL), limit of quantification (0.5 ng/mL for human insulin), precision (CV  0.99), recovery, accuracy (>90%), robustness (plasma/serum), and ion suppression. For quantification of human insulin a labelled internal standard ([[(2) H10 ]-Leu(B6,B11,B15,B17) ] - human Insulin) is introduced. By means of the additional ion mobility separation of the different analogues, the chromatographic run time is shortened to 8 min without losing specificity. As proof-of-concept, the procedure was successfully applied to different blood specimens from diabetic patients receiving recombinant synthetic analogues. Copyright © 2014 John Wiley & Sons, Ltd.

  1. Rapid enzymatic hydrolysis of masked deoxynivalenol and zearalenone prior to liquid chromatography mass spectrometry or immuniassay analysis

    NARCIS (Netherlands)

    Nielen, M.W.F.; Weijers, C.A.G.M.; Peters, J.; Weignerová, L.; Zuilhof, H.; Franssen, M.C.R.

    2014-01-01

    Recently it has been shown that conjugates (‘masked mycotoxins’) may contribute to the total daily intake of hazardous mycotoxins. Therefore, there is an urgent need for rapid analysis methods that assess the level of both free and masked mycotoxins in food and feed. However, the analysis of masked

  2. A rapid anion-exchange chromatography for measurement of cholesterol concentrations in five lipoprotein classes and estimation of lipoprotein profiles in male volunteers without overt diseases.

    Science.gov (United States)

    Manita, Daisuke; Hirowatari, Yuji; Yoshida, Hiroshi

    2015-11-01

    Analysis of lipoprotein profile gives important clinical information for lipid-lowering therapy which prevents atherosclerotic diseases. The lipoprotein classes can be isolated from serum with ultracentrifugation, which inevitably consumes a long time and needs large serum volume. We have established a method with anion-exchange chromatography with 1.0 µL of the injected volume in 5.2 min for assay of one sample. One-hundred-forty-one male volunteers without overt diseases were divided three groups (Group 1, non-dyslipidemia with LDL-cholesterol [LDL-C] cholesterol (HDL-C) ≥40 mg/dL; Group 2, borderline dyslipidemia with 120 ≤ LDL-C cholesterol, VLDL-cholesterol, and other fraction (chylomicron + lipoprotein [a])-cholesterol (other-C). The within-day and between-day assay coefficients of variation of lipoprotein cholesterol values were 0.33-4.31% and 2.37-9.19%, respectively. The correlation coefficients between values of HDL-C, LDL-C, IDL-C and VLDL-C by the anion-exchange chromatography and those by ultracentrifugal method were 0.97, 0.92, 0.58 and 0.94, respectively. Group 3 had significantly lower HDL-C and higher concentrations of IDL-C, VLDL-C and other-C than did Group 1. Group 2, borderline dyslipidemia, had significantly higher concentrations of IDL-C and VLDL-C than did Group 1. The rapid anion-exchange chromatography assay may be sufficiently applied to the assessment of borderline dyslipidemia. © The Author(s) 2015.

  3. Towards a chromatographic similarity index to establish localised quantitative structure-retention relationships for retention prediction. II Use of Tanimoto similarity index in ion chromatography.

    Science.gov (United States)

    Park, Soo Hyun; Talebi, Mohammad; Amos, Ruth I J; Tyteca, Eva; Haddad, Paul R; Szucs, Roman; Pohl, Christopher A; Dolan, John W

    2017-11-10

    Quantitative Structure-Retention Relationships (QSRR) are used to predict retention times of compounds based only on their chemical structures encoded by molecular descriptors. The main concern in QSRR modelling is to build models with high predictive power, allowing reliable retention prediction for the unknown compounds across the chromatographic space. With the aim of enhancing the prediction power of the models, in this work, our previously proposed QSRR modelling approach called "federation of local models" is extended in ion chromatography to predict retention times of unknown ions, where a local model for each target ion (unknown) is created using only structurally similar ions from the dataset. A Tanimoto similarity (TS) score was utilised as a measure of structural similarity and training sets were developed by including ions that were similar to the target ion, as defined by a threshold value. The prediction of retention parameters (a- and b-values) in the linear solvent strength (LSS) model in ion chromatography, log k=a - blog[eluent], allows the prediction of retention times under all eluent concentrations. The QSRR models for a- and b-values were developed by a genetic algorithm-partial least squares method using the retention data of inorganic and small organic anions and larger organic cations (molecular mass up to 507) on four Thermo Fisher Scientific columns (AS20, AS19, AS11HC and CS17). The corresponding predicted retention times were calculated by fitting the predicted a- and b-values of the models into the LSS model equation. The predicted retention times were also plotted against the experimental values to evaluate the goodness of fit and the predictive power of the models. The application of a TS threshold of 0.6 was found to successfully produce predictive and reliable QSRR models (Qext(F2)2>0.8 and Mean Absolute Error<0.1), and hence accurate retention time predictions with an average Mean Absolute Error of 0.2min. Crown Copyright © 2017

  4. MoS2-Nanosheet-Assisted Coordination of Metal Ions with Porphyrin for Rapid Detection and Removal of Cadmium Ions in Aqueous Media.

    Science.gov (United States)

    Yin, Wenyan; Dong, Xinghua; Yu, Jie; Pan, Jun; Yao, Zhiyi; Gu, Zhanjun; Zhao, Yuliang

    2017-06-28

    Molybdenum disulfide (MoS2) is a two-dimensional (2D) graphene-like material that is gaining great attention because of its potential application in various fields. Here, we reported a self-assembled nanocomposite consisted of MoS2 nanosheets and 5,10,15,20-tetrakis(1-methyl-4-pyridinio)porphyrintetra(p-toluenesulfonate) (TMPyP), named MoS2@TMPyP. This nanocomposite can be used as a sensing probe for low cost, rapid, selective detection of cadmium (Cd(2+)) ions. It is found that a new Soret band at 442 nm in UV-vis absorption spectra represented the coordination of Cd(2+) ions into TMPyP of the MoS2@TMPyP. The coordination rates between TMPyP and Cd(2+) ions is greatly accelerated from 72 h to 20 min with the assistance of MoS2, which is 200 times faster than in the absence of MoS2. The limit of detection (LOD) of the Cd(2+) is as low as 7.2 × 10(-8) mol/L. The binding behavior between the cationic TMPyP and MoS2 nanosheets was corroborated by molecular dynamics simulation and various control experiments. The results demonstrated that electrostatic interaction was the main force for driving TMPyP enriching around the MoS2 surface, resulting in an accelerated complexation of Cd(2+) and TMPyP. Moreover, MoS2@TMPyP nanocomposite can also be used for removing of Cd(2+) in water. The removal efficiency (RF) of the MoS2@TMPyP can reach to 91% for high concentrations of Cd(2+). This work provides a new insight into detection and removal of Cd(2+) ions in water.

  5. Diagnosis of congenital adrenal hyperplasia by rapid determination of 17alpha-hydroxyprogesterone in dried blood spots by gas chromatography/mass spectrometry following microwave-assisted silylation.

    Science.gov (United States)

    Deng, Chunhui; Ji, Jie; Zhang, Lijuan; Zhang, Xiangmin

    2005-01-01

    17alpha-Hydroxyprogesterone (17OHP) is considered to be the biomarker of congential adrenal hyperplasia (CAH). Screening for CAH in newborns by measuring levels of the biomarker of 17OHP has become routine. In the work, a rapid, simple and sensitive technique was developed for the diagnosis of neonatal CAH by the quantitative analysis of 17OHP in neonatal blood spots. The technique was based on microwave-assisted silylation (MAS) followed by gas chromatography/mass spectrometry (GC/MS). In the method, fast derivatization of 17OHP with N,O-bis(trimethylsilyl)trifluoroacetamide was performed by using microwave irradiation, and the trimethylsilyl derivative thus formed was analyzed by GC/MS. The results of the experiment indicate that MAS followed by GC/MS analysis is a rapid, simple and sensitive method for the determination of 17OHP in blood samples. The proposed technique has been shown to have potential as a powerful tool for the rapid diagnosis of neonatal CAH. (c) 2005 John Wiley & Sons, Ltd.

  6. The Profiling and Identification of the Absorbed Constituents and Metabolites of Guizhi Decoction in Rat Plasma and Urine by Rapid Resolution Liquid Chromatography Combined with Quadrupole-Time-of-Flight Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Hongjun Xiang

    2016-09-01

    Full Text Available Guizhi decoction (GZD, a well-known traditional Chinese medicine (TCM prescription consisting of Ramulus Cinnamomi, Radix Paeoniae Alba, Radix Glycyrrhizae, Fructus Jujubae and Rhizoma Zingiberis Recens, is usually used for the treatment of common colds, influenza, and other pyretic conditions in the clinic. However, the absorbed ingredients and metabolic compounds of GZD have not been reported. In this paper, a method incorporating rapid resolution liquid chromatography (RRLC with quadrupole-time-of-flight mass spectrometry (Q-TOF-MS was used to identify ingredients after oral administration of GZD. Identification of the primary components in GZD, drug-containing serum and urine samples was carried out in order to investigate the assimilation and metabolites of the decoction in vivo. By comparing the total ion chromatograms (TICs of GZD, a total of 71 constituents were detected or characterized. By comparing TICs of blank and dosed rat plasma, a total of 15 constituents were detected and identified as prototypes according to their retention time (tR and MS, MS/MS data. Based on this, neutral loss scans of 80 and 176 Da in samples of rat plasma and urine helped us to identify most of the metabolites. Results showed that the predominant metabolic pathways of (epi catechin and gallic acid were sulfation, methylation, glucuronidation and dehydroxylation; the major metabolic pathways of flavone were hydrolysis, sulfation and glucuronidation. Furthermore, degradation, oxidation and ring fission were found to often occur in the metabolism process of GZD in vivo.

  7. Rapid determination of cocamidopropyl betaine impurities in cosmetic products by core-shell hydrophilic interaction liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Wang, Perry G; Zhou, Wanlong

    2016-08-26

    Cocamidopropyl betaine (CAPB) is a common surfactant widely used in personal care products. Dimethylaminopropylamine (DMAPA) and lauramidopropyldimethylamine (LAPDMA) are two chemicals present as impurities in CAPB and have been reported as skin sensitizers. A rapid and sensitive ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method, using a core shell hydrophilic interaction liquid chromatography (HILIC) column, has been developed to quantify DMAPA and LAPDMA in cosmetic products. Corresponding stable isotopically labeled analogues of the above native compounds were used as internal standards to compensate for matrix effect and for loss of recovery. Each sample was first screened to determine whether the sample needed to be diluted to minimize matrix effects as well as to fit the calibration range. The concept of matrix effect factor (MEF) was introduced to quantitatively evaluate each sample with a unique matrix using the internal standards. Recoveries at three spiking levels of low, medium, and high concentrations ranged from 98.4 to 112% with RSDs less than 5%. This method has been validated and is the first UHPLC-MS/MS method, which uses core shell HILIC column and stable isotopically labeled internal standards to simultaneously determine these two CAPB impurities in cosmetic products. Published by Elsevier B.V.

  8. Rapid determination of amino acids in fruits of Ziziphus jujuba by hydrophilic interaction ultra-high-performance liquid chromatography coupled with triple-quadrupole mass spectrometry.

    Science.gov (United States)

    Guo, Sheng; Duan, Jin-ao; Qian, Dawei; Tang, Yuping; Qian, Yefei; Wu, Dawei; Su, Shulan; Shang, Erxin

    2013-03-20

    In this study, a sensitive and rapid method for the simultaneous determination of free amino acids without derivatization using hydrophilic interaction liquid chromatography coupled with tandem mass spectrometry (HILIC-MS/MS) was developed. The method was performed on an ultra-high-performance liquid chromatography (UHPLC) separation system coupled with a triple-quadrupole mass spectrometry (TQ-MS) instrument. Sufficient separation of 23 underivatized amino acids was achieved on an Acquity BEH Amide column (2.1 mm × 100 mm, 1.7 μm) in a single run of 12 min. Then the method was applied for the analysis of the free amino acids in 46 batches of Ziziphus jujuba fruits which comprised 39 cultivars from 26 cultivation regions. Multivariate statistical analysis was also used to investigate the differences in free amino acid profiles among the samples. This study showed that HILIC-UHPLC-TQ-MS is an effective technique to analyze underivatized amino acids in the food samples.

  9. Rapid simultaneous analysis of oxyhalides and inorganic anions in aqueous media by ion exchange chromatography with indirect UV detection

    Directory of Open Access Journals (Sweden)

    Mohammadine El Haddad

    2015-01-01

    Best separations have also occured between(Cl-/ClO3- and(Br-/BrO3- with good a resolution. Detections limits (S/N = 3 ofBrO3-,ClO3-andNO3- were 2 and 5 ppm for inorganic anions Cl−, Br− andSO42-. The method had a good linearity (r2 > 0.995 and high precision (relative standard deviation <4%. The main reason for the detector choice was that UV detectors are widespread in educational and low level equipment laboratories. Indirect photometric detection is an attractive and inexpensive approach and the system is versatile.

  10. Rapid characterisation and identification of compounds in Saposhnikoviae Radix by high-performance liquid chromatography coupled with electrospray ionisation quadrupole time-of-flight mass spectrometry.

    Science.gov (United States)

    Chen, Luxiao; Chen, Xiangyang; Su, Lei; Jiang, Yanyan; Liu, Bin

    2017-08-18

    Saposhnikoviae Radix (SR), the dried root of Saposhnikovia divaricata (Turcz.) Schischk. (Umbelliferae), is commonly used as a traditional Chinese medicine. In this study, a rapid and accurate method was firstly, developed for the qualitative analysis of SR by high-performance liquid chromatography coupled with electrospray ionisation quadrupole time-of-flight mass spectrometry (HPLC-ESI-Q-TOF-MS/MS). A total of 45 compounds were identified or tentatively characterised, including 13 chromones, 28 coumarins and four others. Among them, 16 compounds were identified from SR for the first time. In addition, six chromones reference standards, including two isolated compounds of 3'-O-angeloylhamaudol and norcimifugin from the extraction of SR, were used to study the fragmentation pathways of chromones. The developed method was effective for characterising the compounds of SR, and the results of the study enriched the understanding of the chemical connotation.

  11. Rapid determination of the binding affinity and specificity of the mushroom Polyporus squamosus lectin using frontal affinity chromatography coupled to electrospray mass spectrometry.

    Science.gov (United States)

    Zhang, B; Palcic, M M; Mo, H; Goldstein, I J; Hindsgaul, O

    2001-02-01

    The binding affinity and specificity of the mushroom Polyporus squamosus lectin has been determined by the recently developed method of frontal affinity chromatography coupled to electrospray mass spectrometry (FAC/MS). A micro-scale affinity column was prepared by immobilizing the lectin ( approximately 25 microg) onto porous glass beads in a tubing column (9.8 microl column volume). The column was then used to screen several oligosaccharide mixtures. The dissociation constants of 22 sialylated or sulfated oligosaccharides were evaluated against the immobilized lectin. The lectin was found to be highly specific for Neu5Acalpha2-6Galbeta1-4Glc/GlcNAc containing oligosaccharides with K(d) values near 10 microM. The FAC/MS assay permits the rapid determination of the dissociation constants of ligands as well as a higher throughput screening of compound mixtures, making it a valuable tool for affinity studies, especially for testing large numbers of compounds.

  12. Determination of tricarboxylic acid cycle acids and other related substances in cultured mammalian cells by gradient ion-exchange chromatography with suppressed conductivity detection.

    Science.gov (United States)

    Lu, Subiao; Sun, Xiangming; Shi, Chaoou; Zhang, Yuanxing

    2003-09-19

    An ion-exchange chromatography method was established for simultaneously analyzing the tricarboxylic acid (TCA) cycle acids and other related substances in cultured mammalian cells, including citrate, cis-aconitate, isocitrate, alpha-ketoglutarate, succinate, malate, fumarate, oxaloacetate, trans-aconitate, phosphate, lactate and pyruvate. A Dionex 600 ion chromatograph with an ion suppressor and a conductivity detector, and an IonPac AS11-HC analytical column were employed. An NaOH gradient elution containing 13.5% methanol contributed to sufficient separation of target substances. The stability of carboxylic acids was investigated and oxaloacetate was found to be extremely unstable especially at pH 3. TCA cycle acids and other related substances in Chinese hamster ovary (CHO) cells were separated completely, and lactate, malate, phosphate, citrate and cis-aconitate were quantified due to their higher concentrations. In the quantification of the five substances, detection limits (S/N=3) ranged from 0.12 to 0.48 microM, the correlation coefficients from 0.9982 to 1.0000 in their linear ranges of concentration, and the recoveries from 87 to 95%. The metabolic status of CHO cells was analyzed on the basis of the intracellular concentrations of TCA cycle acids.

  13. A practical strategy for the characterization of coumarins in Radix Glehniae by liquid chromatography coupled with triple quadrupole-linear ion trap mass spectrometry.

    Science.gov (United States)

    Yang, Wei; Ye, Min; Liu, Man; Kong, Dezhi; Shi, Rui; Shi, Xiaowei; Zhang, Kerong; Wang, Qiao; Lantong, Zhang

    2010-07-02

    The aim of the present study was to develop a practical method for the characterization of coumarins in Radix Glehniae by liquid chromatography-mass spectrometry (LC-MS). First, 10 coumarin standards (including two pairs of isomers) were studied, and mass spectrometry fragmentation patterns and elution time rules for the coumarins were found. Then, an extract of Radix Glehniae was analyzed by the combination of two scan modes, i.e., multiple ion monitoring-information-dependent acquisition-enhanced product ion mode (MIM-IDA-EPI) and precursor scan information-dependent acquisition-enhanced product ion mode (PREC-IDA-EPI) on a hybrid triple quadrupole-linear ion trap mass spectrometer. A total of 41 coumarins were identified on the basis of their mass spectrometry fragmentation patterns. This is the first time that these two scan modes have been combined to characterize chemical constituents in traditional Chinese medicine. This new method allowed the identification of coumarins in Radix Glehniae in trace amounts. The methodology proposed in this study could be valuable for the structural characterization of coumarins from complex natural and synthetic sources. Copyright 2010 Elsevier B.V. All rights reserved.

  14. Enhancing the power of liquid chromatography-mass spectrometry-based urine metabolomics in negative ion mode by optimization of the additive.

    Science.gov (United States)

    Zhang, Xumin; Clausen, Morten Rahr; Zhao, Xiaolu; Zheng, Hong; Bertram, Hanne Christine

    2012-09-18

    Untargeted liquid chromatography-mass spectrometry (LC-MS)-based metabolomics studies are usually carried out in both positive and negative ion modes; however, it is frequently ignored that the optimal conditions in positive ion mode and negative ion mode are often not the same. We carried out a systematic investigation on urine samples to evaluate the additive effects in negative ion mode. It was found that the widely used conditions, 0.1% formic acid (FA) and NH(4)Ac at different pH, are far from the optimum for untargeted urine metabolomics studies. Compared to 0.1% FA, the use of 1 mM acetic acid (HAc) resulted in almost three times as many detected peaks (401 vs 148) and around five times the size of the peak area (33.55 × 10(6) vs 6.47 × 10(6)). The remarkable improvement can be explained by two factors: (i) a significantly enhanced ionization efficiency due to the combination of an appropriate pH at around 4.0-4.5, the reducibility of H(+), and the high gas-phase basicity of Ac(-) and (ii) a reproducible LC separation due to an acceptable buffering capacity. Our study revealed the importance and necessity of additive optimization, which can be of benefit in related metabolomics studies.

  15. Water quality monitoring system for determination of ionic nutrients by ion-exclusion chromatography with spectrophotometric detection on cation- and anion-exchange resin columns using water eluent.

    Science.gov (United States)

    Kozaki, Daisuke; Nakatani, Nobutake; Mori, Masanobu; Nakagoshi, Nobukazu; Tanaka, Kazuhiko

    2012-07-01

    A unified ion-exclusion chromatography (IEC) system for monitoring anionic and cationic nutrients like NH4+, NO2-, NO3-, phosphate ion, silicate ion and HCO3- was developed and applied to several environmental waters. The IEC system consisted of four IEC methodologies, including the IEC with ultraviolet (UV) form connected with detection at 210 nm for determining NH4+ on anion-exchange separation column in OH anion-exchange UV-conversion column in I- form in tandem, the IEC with UV-detection at 210 nm for determining simultaneously NO3- and NO3- on cation-exchange separation column in H+ form, the IEC with UV-detection at 210 nm for determining HCO3- on cation-exchange separation column in H+ form connected with anion-exchange UV-conversion column in I- form in tandem, and the IEC with visible-detection based on molybdenum-blue reaction for determining simultaneously silicate and phosphate ions on cation-exchange separation column in H+ form. These IEC systems were combined through three manually-driven 6-port column selection valves to select each separation column to determine selectively the ionic nutrients. Using this sequential water quality monitoring system, the analytical performances such as calibration linearity, reproducibility, detection limit and recovery were also tested under the optimized chromatographic conditions. This novel water quality monitoring system has been applied successfully for the determination of the ionic eutrophication components in sub-urban river waters.

  16. Reverse Iontophoretic Extraction of Metabolites from Living Plants and their Identification by Ion-chromatography Coupled to High Resolution Mass Spectrometry.

    Science.gov (United States)

    Sánchez, Maria Isabel González; McCullagh, James; Guy, Richard H; Compton, Richard G

    2017-05-01

    The identification and characterisation of cellular metabolites has now become an important strategy to obtain insight into functional plant biology. However, the extraction of metabolites for identification and analysis is challenging and, at the present time, usually requires destruction of the plant. To detect different plant metabolites in living plants with no pre-treatment using the combination of iontophoresis and ion-chromatography with mass spectrometry detection. In this work, the simple and non-destructive method of reverse iontophoresis has been used to extract in situ multiple plant metabolites from intact Ocimum basilicum leaves. Subsequently, the analysis of these metabolites has been performed with ion chromatography coupled directly to high resolution mass spectrometric detection (IC-MS). The application of reverse iontophoresis to living plant samples has avoided the need for complex pre-treatments. With this approach, no less than 24 compounds, including organic acids and sugars as well as adenosine triphosphate (ATP) were successfully detected. The research demonstrates that it is feasible to monitor, therefore, a number of important plant metabolites using a simple, relatively fast and non-destructive approach. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  17. One-step refolding and purification of recombinant human tumor necrosis factor-α (rhTNF-α) using ion-exchange chromatography.

    Science.gov (United States)

    Wang, Yan; Ren, Wenxuan; Gao, Dong; Wang, Lili; Yang, Ying; Bai, Quan

    2015-02-01

    Protein refolding is a key step for the production of recombinant proteins, especially at large scales, and usually their yields are very low. Chromatographic-based protein refolding techniques have proven to be superior to conventional dilution refolding methods. High refolding yield can be achieved using these methods compared with dilution refolding of proteins. In this work, recombinant human tumor necrosis factor-α (rhTNF-α) from inclusion bodies expressed in Escherichia coli was renatured with simultaneous purification by ion exchange chromatography with a DEAE Sepharose FF column. Several chromatographic parameters influencing the refolding yield of the denatured/reduced rhTNF-α, such as the urea concentration, pH value and concentration ratio of glutathione/oxidized glutathione in the mobile phase, were investigated in detail. Under optimal conditions, rhTNF-α can be renatured and purified simultaneously within 30 min by one step. Specific bioactivity of 2.18 × 10(8) IU/mg, purity of 95.2% and mass recovery of 76.8% of refolded rhTNF-α were achieved. Compared with the usual dilution method, the ion exchange chromatography method developed here is simple and more effective for rhTNF-α refolding in terms of specific bioactivity and mass recovery. Copyright © 2014 John Wiley & Sons, Ltd.

  18. Lateral flow microarrays: a novel platform for rapid nucleic acid detection based on miniaturized lateral flow chromatography

    OpenAIRE

    Carter, Darren J.; Cary, R. Bruce

    2007-01-01

    Widely used nucleic acid assays are poorly suited for field deployment where access to laboratory instrumentation is limited or unavailable. The need for field deployable nucleic acid detection demands inexpensive, facile systems without sacrificing information capacity or sensitivity. Here we describe a novel microarray platform capable of rapid, sensitive nucleic acid detection without specialized instrumentation. The approach is based on a miniaturized lateral flow device that makes use of...

  19. Rapid Quantification of Major Volatile Metabolites in Fermented Food and Beverages Using Gas Chromatography-Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Farhana R. Pinu

    2017-07-01

    Full Text Available Here we present a method for the accurate quantification of major volatile metabolites found in different food and beverages, including ethanol, acetic acid and other aroma compounds, using gas chromatography coupled to mass spectrometry (GC-MS. The method is combined with a simple sample preparation procedure using sodium chloride and anhydrous ethyl acetate. The GC-MS analysis was accomplished within 4.75 min, and over 80 features were detected, of which 40 were positively identified using an in-house and a commercialmass spectrometry (MS library. We determined different analytical parameters of these metabolites including the limit of detection (LOD, limit of quantitation (LOQ and range of quantification. In order to validate the method, we also determined detailed analytical characteristics of five major fermentation end products including ethanol, acetic acid, isoamyl alcohol, ethyl-L-lactate and, acetoin. The method showed very low technical variability for the measurements of these metabolites in different matrices (<3% with an excellent accuracy (100% ± 5%, recovery (100% ± 10%, reproducibility and repeatability [Coefficient of variation (CV 1–10%]. To demonstrate the applicability of the method, we analysed different fermented products including balsamic vinegars, sourdough, distilled (whisky and non-distilled beverages (wine and beer.

  20. Rapid and sensitive detection of carbapenemase activity in Acinetobacter baumannii using superficially porous liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Lin, Huei-Ru; Hu, Anren; Lai, Meng-Jiun; Chiang, Chih-Wei; Liao, Chao-Chuan; Chang, Kai-Chih

    2016-12-01

    The emergence and spread of carbapenem-resistant Acinetobacter baumannii poses a challenge for optimizing antibiotic therapies and preventing outbreaks. Traditional phenotypic assays such as the modified Hodge test (MHT) or polymerase chain reaction (PCR)-based detection of the carbapenemase genes are time-consuming and complicated. Therefore, new approaches for the efficient detection of carbapenemase-producing A. baumannii are urgently required. In this study, we used the superficially porous liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay to measure carbapenem hydrolysis in a solution spiked with test strains of A. baumannii. The rate of carbapenem hydrolysis during incubation was expressed as the ratio of the carbapenem peak area of the test A. baumannii strains to the noncarbapenemase-producing A. baumannii ATCC 17978. This method can accurately measure the carbapenem hydrolysis rate and, therefore, can effectively identify carbapenemase-producing strains within 75 minutes. A total of 112 A. baumannii strains were used in this study, including 103 clinical isolates with 68 carbapenem-resistant strains and 35 carbapenem-susceptible strains, seven ATCC strains and two selected mutants. The results of the superficially porous LC-MS/MS assay showed higher detection sensitivity compared to the results of the MHT. Our results demonstrate the ability of the former method to routinely detect carbapenemase-producing A. baumannii. Copyright © 2015. Published by Elsevier B.V.

  1. Rapid detection of the addition of soybean proteins to cheese and other dairy products by reversed-phase perfusion chromatography.

    Science.gov (United States)

    García, M C; Marina, M L

    2006-04-01

    The undeclared addition of soybean proteins to milk products is forbidden and a method is needed for food control and enforcement. This paper reports the development of a chromatographic method for routine analysis enabling the detection of the addition of soybean proteins to dairy products. A perfusion chromatography column and a linear binary gradient of acetonitrile-water-0.1% (v/v) trifluoroacetic acid at a temperature of 60 degrees C were used. A very simple sample treatment consisting of mixing the sample with a suitable solvent (Milli-Q water or bicarbonate buffer (pH=11)) and centrifuging was used. The method enabled the separation of soybean proteins from milk proteins in less than 4 min (at a flow-rate of 3 ml/min). The method has been successfully applied to the detection of soybean proteins in milk, cheese, yogurt, and enteral formula. The correct quantitation of these vegetable proteins has also been possible in milk adulterated at origin with known sources of soybean proteins. The application of the method to samples adulterated at origin also leads to interesting conclusions as to the effect of the processing conditions used for the preparation of each dairy product on the determination of soybean proteins.

  2. Liquid Chromatography-Mass Spectrometry-Based Rapid Secondary-Metabolite Profiling of Marine Pseudoalteromonas sp. M2

    Directory of Open Access Journals (Sweden)

    Woo Jung Kim

    2016-01-01

    Full Text Available The ocean is a rich resource of flora, fauna, and food. A wild-type bacterial strain showing confluent growth on marine agar with antibacterial activity was isolated from marine water, identified using 16S rDNA sequence analysis as Pseudoalteromonas sp., and designated as strain M2. This strain was found to produce various secondary metabolites including quinolone alkaloids. Using high-resolution mass spectrometry (MS and nuclear magnetic resonance (NMR analysis, we identified nine secondary metabolites of 4-hydroxy-2-alkylquinoline (pseudane-III, IV, V, VI, VII, VIII, IX, X, and XI. Additionally, this strain produced two novel, closely related compounds, 2-isopentylqunoline-4-one and 2-(2,3-dimetylbutylqunoline-4-(1H-one, which have not been previously reported from marine bacteria. From the metabolites produced by Pseudoalteromonas sp. M2, 2-(2,3-dimethylbutylquinolin-4-one, pseudane-VI, and pseudane-VII inhibited melanin synthesis in Melan-A cells by 23.0%, 28.2%, and 42.7%, respectively, wherein pseudane-VII showed the highest inhibition at 8 µg/mL. The results of this study suggest that liquid chromatography (LC-MS/MS-based metabolite screening effectively improves the efficiency of novel metabolite discovery. Additionally, these compounds are promising candidates for further bioactivity development.

  3. [Rapid determination of 6 pesticide residues in tomato paste by ultra performance liquid chromatography-tandem mass spectrometry].

    Science.gov (United States)

    Su, Min; Li, Shiyu; Li, Fengge; Gong, Zhiguo; Wang, Jinhua

    2011-11-01

    An ultra performance liquid chromatography-tandem mass spectrometric method (UPLC-MS/MS) was established for the simultaneous determination of imidacloprid, carbendazim, thiophanate-methyl, propamocarb, methomyl and dimethomorph residues in tomato paste. The samples were extracted by methanol-water (1: 1, v/v) containing 0.1% (v/v) acetic acid. The separation was performed on a Waters Acquity UPLC system with a BEH C18 column with the gradient elution of methanol and water (containing 10 mmol/L ammonium acetate). The six pesticides were determined in the modes of electrospray positive ionization (ESI+) and multiple reaction monitoring (MRM). The analytes were quantified by matrix-matched standard solution, and the calibration curves showed good linearity within the concentrations of 0.005 to 0.2 mg/L and the correlation coefficients (r) were more than 0.995. The average recoveries of the six pesticides ranged from 66.8% to 102.9% in the three spiked levels of 0.02, 0.05 and 0.2 mg/kg. The relative standard deviations (RSDs) were all less than 15%. The limits of quantification (LOQ, S/N > 10) were 0.02 mg/kg for the all analytes. The results indicate that the method is easier, faster, more sensitive, and suitable for the qualitative and quantitative confirmation of the six pesticide residues from tomato paste.

  4. A rapid liquid chromatography tandem mass spectrometry-based method for measuring propranolol on dried blood spots.

    Science.gov (United States)

    Della Bona, Maria Luisa; Malvagia, Sabrina; Villanelli, Fabio; Giocaliere, Elisa; Ombrone, Daniela; Funghini, Silvia; Filippi, Luca; Cavallaro, Giacomo; Bagnoli, Paola; Guerrini, Renzo; la Marca, Giancarlo

    2013-05-05

    Propranolol, a non-selective beta blocker drug, is used in young infants and newborns for treating several heart diseases; its pharmacokinetics has been extensively evaluated in adult patients using extrapolation to treat pediatric population. The purpose of the present study was to develop and validate a method to measure propranolol levels in dried blood spots. The analysis was performed by using liquid chromatography/tandem mass spectrometry operating in multiple reaction monitoring mode. The calibration curve in matrix was linear in the concentration range of 2.5-200 μg/L with correlation coefficient r=0.9996. Intra-day and inter-day precisions and biases were less than 8.0% (n=10) and 11.5% (n=10) respectively. The recoveries ranged from 94 to 100% and the matrix effect did not result in a severe signal suppression. Propranolol on dried blood spot showed a good stability at three different temperatures for one month. This paper describes a micromethod for measuring propranolol levels on dried blood spot, which determines a great advantage in neonates or young infants during pharmacokinetic studies because of less invasive sampling and small blood volume required. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. Rapid "one-pot" preparation of polymeric monolith via photo-initiated thiol-acrylate polymerization for capillary liquid chromatography.

    Science.gov (United States)

    Bai, Jingyao; Wang, Hongwei; Ou, Junjie; Liu, Zhongshan; Shen, Yehua; Zou, Hanfa

    2016-06-21

    A facile approach was exploited for fast preparation of polymer-based monoliths in UV-transparent fused-silica capillaries via "one-pot" photo-initiated thiol-acrylate polymerization reaction of dipentaerythritolpenta-/hexaacrylate (DPEPA) and 1-octadecanethiol (ODT) in the presence of porogenic solvents (1-butanol and ethylene glycol). Due to relative insensitivity of oxygen inhibition in thiol-ene free-radical polymerization, the polymerization could be performed within 5 min. The effects of composition of prepolymerization solution on the morphology and permeability of poly(ODT-co-DPEPA) monoliths were investigated in detail by adjusting the content of monomer and binary porogen ratio. The physical properties of poly(ODT-co-DPEPA) monoliths were characterized by Fourier transform infrared spectroscopy (FT-IR), mercury intrusion porosimetry (MIP) and nitrogen adsorption/desorption measurement. The evaluation of chromatographic performance was carried out by capillary liquid chromatography (cLC). The results indicated that the poly(ODT-co-DPEPA) monolith was homogeneous and permeable, and also possessed a typical reversed-phase retention mechanism in cLC with high efficiency (∼75,000 N m(-1)) for separation of alkylbenzenes. Eventually, the further separation of tryptic digest of proteins by cLC tandem mass spectrometry (cLC-MS/MS) demonstrated its potential in the analysis of biological samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Rapid Quantification of Major Volatile Metabolites in Fermented Food and Beverages Using Gas Chromatography-Mass Spectrometry.

    Science.gov (United States)

    Pinu, Farhana R; Villas-Boas, Silas G

    2017-07-26

    Here we present a method for the accurate quantification of major volatile metabolites found in different food and beverages, including ethanol, acetic acid and other aroma compounds, using gas chromatography coupled to mass spectrometry (GC-MS). The method is combined with a simple sample preparation procedure using sodium chloride and anhydrous ethyl acetate. The GC-MS analysis was accomplished within 4.75 min, and over 80 features were detected, of which 40 were positively identified using an in-house and a commercialmass spectrometry (MS) library. We determined different analytical parameters of these metabolites including the limit of detection (LOD), limit of quantitation (LOQ) and range of quantification. In order to validate the method, we also determined detailed analytical characteristics of five major fermentation end products including ethanol, acetic acid, isoamyl alcohol, ethyl-L-lactate and, acetoin. The method showed very low technical variability for the measurements of these metabolites in different matrices (<3%) with an excellent accuracy (100% ± 5%), recovery (100% ± 10%), reproducibility and repeatability [Coefficient of variation (CV) 1-10%)]. To demonstrate the applicability of the method, we analysed different fermented products including balsamic vinegars, sourdough, distilled (whisky) and non-distilled beverages (wine and beer).

  7. Evaluation of several protein a resins for application to multicolumn chromatography for the rapid purification of fed-batch bioreactors.

    Science.gov (United States)

    Hilbold, Nicolas-Julian; Le Saoût, Xavier; Valery, Eric; Muhr, Laurence; Souquet, Jonathan; Lamproye, Alain; Broly, Hervé

    2017-07-01

    Most of the existing production capacity is based on fed-batch bioreactors. Thanks to the development of more efficient cell lines and the development of high-performance culture media, cell productivity dramatically increased. In a manufacturing perspective, it is necessary to clear as quickly as possible the protein A capture step to respect the manufacturing agenda. This article describes the methodology applied for the design of a multicolumn chromatography process with the objective of purifying as quickly as possible 1,000 and 15,000 L fed-batch bioreactors. Several recent and reference protein A resins are compared based on characteristic values obtained from breakthrough curves. The importance and relevance of resin parameters are explained, and purposely simple indicators are proposed to quickly evaluate the potential of each candidate. Based on simulation data, the optimum BioSC systems associated with each resin are then compared. The quality of the elution delivered by each resin is also compared to complete the assessment. © 2017 American Institute of Chemical Engineers Biotechnol. Prog., 33:941-953, 2017. © 2017 American Institute of Chemical Engineers.

  8. Recent applications of hydrophilic interaction liquid chromatography in pharmaceutical analysis.

    Science.gov (United States)

    Zhang, Qian; Yang, Feng-Qing; Ge, Liya; Hu, Yuan-Jia; Xia, Zhi-Ning

    2017-01-01

    Hydrophilic interaction liquid chromatography, an alternative liquid chromatography mode, is of particular interest in separating hydrophilic and polar ionic compounds. Compared with traditional liquid chromatography techniques, hydrophilic interaction liquid chromatography offers specific advantages mainly including: (1) relatively green and water-soluble mobile phase composition, which enhances the solubility of hydrophilic and polar ionic compounds; (2) no need for ion-pairing reagents and high content of organic solvent, which benefits mass spectrometry detection; (3) high orthogonality to reverse-phase liquid chromatography, well adapted to two-dimensional liquid chromatography for complicated samples. Therefore, hydrophilic interaction liquid chromatography has been rapidly developed in many areas over the past decades. This review summarizes the recent progress (from 2012 to July 2016) of hydrophilic interaction liquid chromatography in pharmaceutical analysis, with the focus on detecting chemical drugs in various matrices, charactering active compounds of natural products and assessing biotherapeutics through typical structure unit. Moreover, the retention mechanism and behavior of analytes in hydrophilic interaction liquid chromatography as well as some novel hydrophilic interaction liquid chromatography columns used for pharmaceutical analysis are also described. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. An improved pseudotargeted metabolomics approach using multiple ion monitoring with time-staggered ion lists based on ultra-high performance liquid chromatography/quadrupole time-of-flight mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Yang; Liu, Fang; Li, Peng; He, Chengwei; Wang, Ruibing; Su, Huanxing; Wan, Jian-Bo, E-mail: jbwan@umac.mo

    2016-07-13

    Pseudotargeted metabolomics is a novel strategy integrating the advantages of both untargeted and targeted methods. The conventional pseudotargeted metabolomics required two MS instruments, i.e., ultra-high performance liquid chromatography/quadrupole-time- of-flight mass spectrometry (UHPLC/Q-TOF MS) and UHPLC/triple quadrupole mass spectrometry (UHPLC/QQQ-MS), which makes method transformation inevitable. Furthermore, the picking of ion pairs from thousands of candidates and the swapping of the data between two instruments are the most labor-intensive steps, which greatly limit its application in metabolomic analysis. In the present study, we proposed an improved pseudotargeted metabolomics method that could be achieved on an UHPLC/Q-TOF/MS instrument operated in the multiple ion monitoring (MIM) mode with time-staggered ion lists (tsMIM). Full scan-based untargeted analysis was applied to extract the target ions. After peak alignment and ion fusion, a stepwise ion picking procedure was used to generate the ion lists for subsequent single MIM and tsMIM. The UHPLC/Q-TOF tsMIM MS-based pseudotargeted approach exhibited better repeatability and a wider linear range than the UHPLC/Q-TOF MS-based untargeted metabolomics method. Compared to the single MIM mode, the tsMIM significantly increased the coverage of the metabolites detected. The newly developed method was successfully applied to discover plasma biomarkers for alcohol-induced liver injury in mice, which indicated its practicability and great potential in future metabolomics studies. - Highlights: • An UHPLC/Q-TOF tsMIM MS-based pseudotargeted metabolomics was proposed. • Compared to full scan, the improved method exhibits better repeatability and a wider linear range. • The proposed method could achieve pseudotargeted analysis on one UHPLC/Q-TOF/MS instrument. • The developed method was successfully used to discover biomarkers for alcohol-induced liver injury.

  10. Local Ion Signatures (LIS) for the examination of comprehensive two-dimensional gas chromatography applied to fire debris analysis

    NARCIS (Netherlands)

    Lopatka, Martin; Sampat, Andjoe A.; Jonkers, Steffan; Adutwum, Lawrence A.; Mol, Hans G.J.; Weg, van der Guido; Harynuk, James J.; Schoenmakers, Peter J.; Asten, van Arian; Sjerps, Marjan J.; Vivó-Truyols, Gabriel

    2017-01-01

    Forensic examination of fire debris evidence is a notoriously difficult analytical task due to the complexity and variability of sample composition. The use of comprehensive two-dimensional gas chromatography with mass spectrometry detection (GC × GC–MS) allows the coupling of orthogonal

  11. Boehringer immunoinhibition procedure for creatine kinase-MB evaluated and compared with column ion-exchange chromatography

    NARCIS (Netherlands)

    ter Welle, H. F.; Baartscheer, T.; Fiolet, J. W.

    1983-01-01

    In determination of creatine kinase isoenzyme MB (CK-MB), the Boehringer immunoinhibition method gives a high and variable blank activity as compared with column-chromatography. Thus a correction must be applied. Furthermore, a second correction of 1% of total creatine kinase activity is necessary

  12. Virtual Protein Purification: A Simple Exercise to Introduce pH as A Parameter That Effects Ion Exchange Chromatography

    Science.gov (United States)

    Clark, Daniel D.; Edwards, Daniel J.

    2018-01-01

    This article describes a simple exercise using a free, easy-to-use, established online program. The exercise helps to reinforce protein purification concepts and introduces undergraduates to pH as a parameter that affects anion-exchange chromatography. The exercise was tested with biochemistry majors at California State University-Chico. Given the…

  13. A multiple-dimension liquid chromatography coupled with mass spectrometry data strategy for the rapid discovery and identification of unknown compounds from a Chinese herbal formula (Er-xian decoction).

    Science.gov (United States)

    Wang, Caihong; Zhang, Jinlan; Wu, Caisheng; Wang, Zhe

    2017-10-06

    It is very important to rapidly discover and identify the multiple components of traditional Chinese medicine (TCM) formula. High performance liquid chromatography with high resolution tandem mass spectrometry (HPLC-HRMS/MS) has been widely used to analyze TCM formula and contains multiple-dimension data including retention time (RT), high resolution mass (HRMS), multiple-stage mass spectrometric (MSn), and isotope intensity distribution (IID) data. So it is very necessary to exploit a useful strategy to utilize multiple-dimension data to rapidly probe structural information and identify chemical compounds. In this study, a new strategy to initiatively use the multiple-dimension LC-MS data has been developed to discover and identify unknown compounds of TCM in many styles. The strategy guarantees the fast discovery of candidate structural information and provides efficient structure clues for identification. The strategy contains four steps in sequence: (1) to discover potential compounds and obtain sub-structure information by the mass spectral tree similarity filter (MTSF) technique, based on HRMS and MSn data; (2) to classify potential compounds into known chemical classes by discriminant analysis (DA) on the basis of RT and HRMS data; (3) to hit the candidate structural information of compounds by intersection sub-structure between MTSF and DA (M,D-INSS); (4) to annotate and confirm candidate structures by IID data. This strategy allowed for the high exclusion efficiency (greater than 41%) of irrelevant ions in er-xian decoction (EXD) while providing accurate structural information of 553 potential compounds and identifying 66 candidates, therefore accelerating and simplifying the discovery and identification of unknown compounds in TCM formula. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Rapid wide-scope screening of drugs of abuse, prescription drugs with potential for abuse and their metabolites in influent and effluent urban wastewater by ultrahigh pressure liquid chromatography-quadrupole-time-of-flight-mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez, Felix, E-mail: felix.hernandez@qfa.uji.es [Research Institute for Pesticides and Water, University Jaume I, Avda. Sos Baynat s/n, E-12071 Castellon (Spain); Bijlsma, Lubertus, E-mail: bijlsma@guest.uji.es [Research Institute for Pesticides and Water, University Jaume I, Avda. Sos Baynat s/n, E-12071 Castellon (Spain); Sancho, Juan V.; Diaz, Ramon; Ibanez, Maria [Research Institute for Pesticides and Water, University Jaume I, Avda. Sos Baynat s/n, E-12071 Castellon (Spain)

    2011-01-17

    This work illustrates the potential of hybrid quadrupole-time-of-flight mass spectrometry (QTOF MS) coupled to ultrahigh pressure liquid chromatography (UHPLC) to investigate the presence of drugs of abuse in wastewater. After solid-phase extraction with Oasis MCX cartridges, seventy-six illicit drugs, prescription drugs with potential for abuse, and metabolites were investigated in the samples by TOF MS using electrospray interface under positive ionization mode, with MS data acquired over an m/z range of 50-1000 Da. For 11 compounds, reference standards were available, and experimental data (e.g., retention time and fragmentation data) could be obtained, facilitating a more confident identification. The use of a QTOF instrument enabled the simultaneous application of two acquisition functions with different collision energies: a low energy (LE) function, where none or poor fragmentation took place, and a high energy (HE) function, where fragmentation in the collision cell was promoted. This approach, known as MS{sup E}, enabled the simultaneous acquisition of full-spectrum accurate mass data of both protonated molecules and fragment ions in a single injection, providing relevant information that facilitates the rapid detection and reliable identification of these emerging contaminants in the sample matrices analyzed. In addition, isomeric compounds, like the opiates, morphine and norcodeine, could be discriminated by their specific fragments observed in HE TOF MS spectra, without the need of reference standards. UHPLC-QTOF MS was proven to be a powerful and efficient technique for rapid wide-scope screening and identification of many relevant drugs in complex matrices, such as influent and effluent urban wastewater.

  15. [Rapid determination of benzene series in seawater by gas chromatography-mass spectrometry with static headspace extraction].

    Science.gov (United States)

    Bai, Hongyan; Han, Bin; Chen, Junhui; Zheng, Li; Yang, Dongfang; Wang, Xiaoru

    2012-05-01

    A method for the simultaneous determination of 13 benzene series (BTEX) in seawater using gas chromatography-mass spectrometry with static headspace extraction (HS-GC/MS) was developed. To carefully characterize the performance of this method, several factors affecting parameters were studied in detail, such as the type of column, heating procedure, equilibrium temperature, equilibrium time and the volume ratio of gas phase to liquid phase. The optimized conditions were as follows: the polar column of DB-WAX; heating procedure, 40 degrees C kept for 4 min, then raised to 120 degrees C at 10 degrees C/min, to 180 degrees C at 25 degrees C/min; equilibrium temperature, 80 degrees C; equilibrium time, 10 min; and the volume ratio of gas phase to liquid phase, 1:1. Under the optimized conditions, the linear equations were obtained in the concentration range of 0.16-320 microg/L with correlation coefficients greater than 0.999. The limits of detection (S/N = 3) were 0.019-0.033 microg/L. The recoveries at the three spiked levels of 1.6, 16 and 160 microg/L ranged from 81. 25% to 103.73% with the relative standard deviations (RSD, n=6) from 0.3% to 4.4%. The analytical results of the practical seawater samples from Shanghai Huangpu District were satisfactory. The determination of the 13 benzene series can be finished in 12 min. The method is simple, accurate, reliable, efficient and environmental-friendly.

  16. Rapid isolation procedure for Δ9-tetrahydrocannabinolic acid A (THCA) from Cannabis sativa using two flash chromatography systems.

    Science.gov (United States)

    Wohlfarth, Ariane; Mahler, Hellmut; Auwärter, Volker

    2011-10-15

    Two isolation procedures for Δ9-tetrahydrocannabinolic acid A (THCA), the biogenetic precursor in the biosynthesis of the psychoactive Δ9-tetrahydrocannabinol (THC) in the cannabis plant, are presented. Two flash chromatography systems that can be used independently from each other were developed to separate THCA from other compounds of a crude cannabis extract. In both systems UV absorption at 209 and 270 nm was monitored. Purity was finally determined by HPLC-DAD, NMR and GC-MS analysis with a focus on the impurity THC. System 1 consisted of a normal phase silica column (120 g) as well as cyclohexane and acetone--both spiked with the modifier pyridine--as mobile phases. Gradient elution was performed over 15 min. After the chromatographic run the fractions containing THCA fractions were pooled, extracted with hydrochloric acid to eliminate pyridine and evaporated to dryness. Loading 1800 mg cannabis extract yielded 623 mg THCA with a purity of 99.8% and a THC concentration of 0.09%. System 2 was based on a reversed-phase C18 column (150 g) combined with 0.55% formic acid and methanol as mobile phases. A very flat gradient was set over 20 minutes. After pooling the THCA-containing fractions methanol was removed in a rotary evaporator. THCA was re-extracted from the remaining aqueous phase with methyl tert-butyl ether. The organic phase was finally evaporated under high vacuum conditions. Loading 300 mg cannabis extract yielded 51 mg THCA with a purity of 98.8% and a THC concentration of 0.67%. Copyright © 2011 Elsevier B.V. All rights reserved.

  17. Simultaneous qualitative and quantitative analysis of 21 mycotoxins in Radix Paeoniae Alba by ultra-high performance liquid chromatography quadrupole linear ion trap mass spectrometry and QuEChERS for sample preparation.

    Science.gov (United States)

    Xing, Yanyan; Meng, Wenting; Sun, Wanyang; Li, Dongxiang; Yu, Zhiguo; Tong, Ling; Zhao, Yunli

    2016-09-15

    A high-throughput method for simultaneous qualitative and quantitative analysis of 21 mycotoxins in Radix Paeoniae Alba (RPA) was developed by coupling the modified QuEChERS method with ultra-high performance liquid chromatography quadrupole linear ion trap mass spectrometry (UHPLC-QqLIT-MS). The 21 mycotoxins were extracted and cleaned up using QuEChERS-based procedure, then further separated on a C18 column and detected by a hybrid triple quadrupole linear ion trap mass spectrometer equipped with electrospray ionization source in the multiple reaction monitoring-information dependent acquisition-enhanced product ion (MRM-IDA-EPI) mode. Under this technique, 13 mycotoxins were detected using acetonitrile and water containing 0.1% formic acid as the mobile phase in positive mode while the other 8 mycotoxins were detected using acetonitrile and water containing 0.1% ammonia as the mobile phase in negative mode. The calibration curves of all analytes showed good linearity (r(2)>0.995) within test ranges. The limits of detection and quantification ranged from 0.031 to 5.4μg/kg and 0.20 to 22μg/kg, respectively. Additionally, recoveries were all above 75.3% with relative standard deviations within 15%. The method proposed herein with significant advantages including simple pretreatment, rapid determination as well as high sensitivity, accuracy and throughput would be a preferred candidate for the determination and quantification of multi-class mycotoxin contaminants in real samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Determination of red blood cell fatty acid profiles: Rapid and high-confident analysis by chemical ionization-gas chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Schober, Yvonne; Wahl, Hans Günther; Renz, Harald; Nockher, Wolfgang Andreas

    2017-01-01

    Cellular fatty acid (FA) profiles have been acknowledged as biomarkers in various human diseases. Nevertheless, common FA analysis by gas chromatography mass spectrometry (GC-MS) requires long analysis time. Hence, there is a need for feasible methods for high throughput analysis in clinical studies. FA was extracted from red blood cells (RBC) and derivatized to fatty acid methyl esters (FAME). A method using gas chromatography tandem mass spectrometry (GC-MS/MS) with ammonia-induced chemical ionization (CI) was developed for the analysis of FA profiles in human RBC. We compared this method with classical single GC-MS using electron impact ionization (EI). The FA profiles of 703 RBC samples were determined by GC-MS/MS. In contrast to EI ammonia-induced CI resulted in adequate amounts of molecular ions for further fragmentation of FAME. Specific fragments for confident quantification and fragmentation were determined for 45 FA. The GC-MS/MS method has a total run time of 9min compared to typical analysis times of up to 60min in conventional GC-MS. Intra and inter assay variations were Analysis of RBC FA composition revealed an age-dependent increase of the omega-3 eicosapentaenoic and docosahexaenoic acid, and a decline of the omega-6 linoleic acid with a corresponding rise of the omega-3 index. The combination of ammonia-induced CI and tandem mass spectrometry after GC separation allows for high-throughput, robust and confident analysis of FA profiles in the clinical laboratory. Copyright © 2016. Published by Elsevier B.V.

  19. Separation of aliphatic carboxylic acids and benzenecarboxylic acids by ion-exclusion chromatography with various cation-exchange resin columns and sulfuric acid as eluent.

    Science.gov (United States)

    Ohta, Kazutoku; Ohashi, Masayoshi; Jin, Ji-Ye; Takeuchi, Toyohide; Fujimoto, Chuzo; Choi, Seong-Ho; Ryoo, Jae-Jeong; Lee, Kwang-Pill

    2003-05-16

    The application of various hydrophilic cation-exchange resins for high-performance liquid chromatography (sulfonated silica gel: TSKgel SP-2SW, carboxylated silica gel: TSKgel CM-2SW, sulfonated polymethacrylate resin: TSKgel SP-5PW, carboxylated polymethacrylate resins: TSKgel CM-5PW and TSKgel OA-Pak A) as stationary phases in ion-exclusion chromatography for C1-C7 aliphatic carboxylic acids (formic, acetic, propionic, butyric, isovaleric, valeric, isocaproic, caproic, 2-methylhexanoic and heptanoic acids) and benzenecarboxylic acids (pyromellitic, trimellitic, hemimellitic, o-phthalic, m-phthalic, p-phthalic, benzoic, salicylic acids and phenol) was carried out using diluted sulfuric acid as the eluent. Silica-based cation-exchange resins (TSKgel SP-2SW and TSKgel CM-2SW) were very suitable for the ion-exclusion chromatographic separation of these benzenecarboxylic acids. Excellent simultaneous separation of these benzenecarboxylic acids was achieved on a TSKgel SP-2SW column (150 x 6 mm I.D.) in 17 min using a 2.5 mM sulfuric acid at pH 2.4 as the eluent. Polymethacrylate-based cation-exchange resins (TSKgel SP-5PW, TSKgel CM-5PW and TSKgel OA-Pak A) acted as advanced stationary phases for the ion-exclusion chromatographic separation of these C1-C7 aliphatic carboxylic acids. Excellent simultaneous separation of these C1-C7 acids was achieved on a TSKgel CM-5PW column (150 x 6 mm I.D.) in 32 min using a 0.05 mM sulfuric acid at pH 4.0 as the eluent.

  20. Simultaneous identification and quantification of tetrodotoxin in fresh pufferfish and pufferfish-based products using immunoaffinity columns and liquid chromatography/quadrupole-linear ion trap mass spectrometry

    Science.gov (United States)

    Guo, Mengmeng; Wu, Haiyan; Jiang, Tao; Tan, Zhijun; Zhao, Chunxia; Zheng, Guanchao; Li, Zhaoxin; Zhai, Yuxiu

    2017-07-01

    In this study, we established a comprehensive method for simultaneous identification and quantification of tetrodotoxin (TTX) in fresh pufferfish tissues and pufferfish-based products using liquid chromatography/quadrupole-linear ion trap mass spectrometry (LC-QqLIT-MS). TTX was extracted by 1% acetic acid-methanol, and most of the lipids were then removed by freezing lipid precipitation, followed by purification and concentration using immunoaffinity columns (IACs). Matrix effects were substantially reduced due to the high specificity of the IACs, and thus, background interference was avoided. Quantitation analysis was therefore performed using an external calibration curve with standards prepared in mobile phase. The method was evaluated by fortifying samples at 1, 10, and 100 ng/g, respectively, and the recoveries ranged from 75.8%-107%, with a relative standard deviation of less than 15%. The TTX calibration curves were linear over the range of 1-1 000 μg/L, with a detection limit of 0.3 ng/g and a quantification limit of 1 ng/g. Using this method, samples can be further analyzed using an information-dependent acquisition (IDA) experiment, in the positive mode, from a single liquid chromatography-tandem mass spectrometry injection, which can provide an extra level of confirmation by matching the full product ion spectra acquired for a standard sample with those from an enhanced product ion (EPI) library. The scheduled multiple reaction monitoring method enabled TTX to be screened for, and TTX was positively identified using the IDA and EPI spectra. This method was successfully applied to analyze a total of 206 samples of fresh pufferfish tissues and pufferfish-based products. The results from this study show that the proposed method can be used to quantify and identify TTX in a single run with excellent sensitivity and reproducibility, and is suitable for the analysis of complex matrix pufferfish samples.

  1. Rapid and simultaneous determination of hexapeptides (Ac-EEMQRR-amide and H2N-EEMQRR-amide) in anti-wrinkle cosmetics by hydrophilic interaction liquid chromatography-solid phase extraction preparation and hydrophilic interaction liquid chromatography with tandem mass spectrometry.

    Science.gov (United States)

    Zhou, Wanlong; Wang, Perry G; Krynitsky, Alexander J; Rader, Jeanne I

    2011-11-04

    A rapid method for the simultaneous determination of Ac-EEMQRR-amide and H(2)N-EEMQRR-amide in cosmetic products was developed and evaluated. This analytical procedure involved extracting samples with 0.1:0.1:85:15 (v:v) trifluoroacetic acid (TFA):formic acid:acetonitrile (ACN):water and determination by hydrophilic interaction liquid chromatography with tandem mass spectrometry (HILIC-MS/MS). Samples showing serious ion suppression were further cleaned up using HILIC-SPE prior to HILIC-MS/MS analysis. Stable isotopically labeled peptides, corresponding to the above two peptides, were used as internal standards to correct for loss of recovery and matrix effects. Electrospray ionization (ESI) in the positive mode was used. The linear range was 2.0-1000 ng/mL for Ac-EEMQRR-amide and 25.0-2500 ng/mL for H(2)N-EEMQRR-amide. Thirteen commercial products were analyzed for the two peptides using this method. The amounts of Ac-EEMQRR-amide in the samples ranged from none detected to 42.3 μg/g. H(2)N-EEMQRR-amide was not detected in any of the samples. The recoveries for Ac-EEMQRR-amide and H(2)N-EEMQRR-amide ranged from 85% to 110% and 84% to 119%, respectively, at the spiking level of 30 μg/g. Published by Elsevier B.V.

  2. A rapid and simple high-performance liquid chromatography assay for the leflunomide metabolite, teriflunomide (A77 1726), in renal transplant recipients.

    Science.gov (United States)

    Sobhani, Kimia; Garrett, Danette A; Liu, Dong-Pei; Rainey, Petrie M

    2010-03-01

    Leflunomide (Arava), a drug with immunosuppressive and antiviral effects, is being used in renal transplant recipients, primarily for its action against BK polyomavirus (BKV), which affects 1% to 10% of renal transplant recipients and often causes failure of grafted kidneys. Leflunomide effects are solely due to an active metabolite, teriflunomide (formerly A77 1726). Trough blood concentrations of teriflunomide exceeding 40 microg/mL (148 micromol/L) are associated with progressive clearance of BKV. Toxic effects become increasingly apparent at higher concentrations. We have developed a rapid, simple, and robust high-performance liquid chromatography (HPLC) method for therapeutic monitoring of teriflunomide in renal transplant recipients. Sample preparation is rapid, and each HPLC separation takes about 7 minutes. Intraday and interday coefficients of variation were 1.5% or less and 5.6% or less, respectively. The method was linear to 200 microg/mL (740 micromol/L), which is well above teriflunomide concentrations that are likely to be observed.

  3. Rapid and sensitive solid phase extraction-large volume injection-gas chromatography for the analysis of mineral oil saturated and aromatic hydrocarbons in cardboard and dried foods.

    Science.gov (United States)

    Moret, Sabrina; Barp, Laura; Purcaro, Giorgia; Conte, Lanfranco S

    2012-06-22

    A rapid off-line solid phase extraction-large volume injection-gas chromatography-flame ionisation detection (SPE-LVI-GC-FID) method, based on the use of silver silica gel and low solvent consumption, was developed for mineral oil saturated hydrocarbon (MOSH) and mineral oil aromatic hydrocarbon (MOAH) determination in cardboard and dried foods packaged in cardboard. The SPE method was validated using LVI with a conventional on-column injector and the retention gap technique (which allowed to inject up to 50 μL of the sample). Detector response was linear over all the concentration range tested (0.5-250 μg/mL), recoveries were practically quantitative, repeatability was good (coefficients of variation lower than 7%) and limit of quantification adequate to quantify the envisioned limit of 0.15 mg/kg proposed in Germany for MOAH analysis in food samples packaged in recycled cardboard. Rapid heating of the GC oven allowed to increase sample throughput (3-4 samples per hour) and to enhance sensitivity. The proposed method was used for MOSH and MOAH determination in selected food samples usually commercialised in cardboard packaging. The most contaminated was a tea sample (102.2 and 7.9 mg/kg of MOSH and MOAH below n-C25, respectively), followed by a rice and a sugar powder sample, all packaged in recycled cardboard. Copyright © 2012 Elsevier B.V. All rights reserved.

  4. Rapid determination of yunaconitine and related alkaloids in aconites and aconite-containing drugs by ultra high-performance liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Song, Long; Zhang, Hong; Liu, Xin; Zhao, Zhi-Li; Chen, Shi-Lin; Wang, Zheng-Tao; Xu, Hong-Xi

    2012-12-01

    Yunaconitine (YAC) is a toxic aconite alkaloid that is considered to be a hidden aconite poison since it is frequently found in body fluids from aconite poisoning patients, but has not been well studied in commonly used herbal drugs. In this paper, a rapid and sensitive ultra high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) detection combined with microwave-assisted extraction (MAE) was developed for high throughput simultaneous determination of YAC and six other toxic aconite alkaloids in 31 samples of crude, processed aconites and aconite-containing drugs. The optimized method showed excellent linearity, precision, accuracy and recovery for all target compounds with short run time. YAC was detected in some samples with contents from 0.015 to 10.41 mg/g. This is the first report on the determination of YAC in Radix Aconiti, Radix Aconiti Kusnezoffii and aconite-containing drugs. This newly developed method facilitates the rapid screening of YAC and related toxic aconite alkaloids and allows YAC to be used as a chemical marker for the quality control of aconites and aconite-containing drugs. Copyright © 2012 John Wiley & Sons, Ltd.

  5. In vivo biosynthesis of L-(/sup 35/S)Cys-arginine vasopressin, -oxytocin, and -somatostatin: rapid estimation using reversed phase high pressure liquid chromatography. [Rats

    Energy Technology Data Exchange (ETDEWEB)

    Franco-Bourland, R.E.; Fernstrom, J.D.

    1981-01-01

    L(/sup 35/S)Cys-arginine vasopressin, -oxytocin, and -somatostatin were purified from hypothalami and neurohypophyses 4 h after rats received L(/sup 35/S)Cys via the third ventricle. After acetic acid extraction, Sephadex G-25 filtration, and chemoadsorption to C18-silica (Sep-Pak cartridges), the labeled peptides were rapidly separated by gradient elution, reversed phase, high pressure liquid chromatography (HPLC). The identity and isotopic purity of the labeled peptides were determined by several reversed phase HPLC procedures in conjunction with chemical modification. The labeled peptide fractions were at least 50% radiochemically pure. Using this HPLC isolation procedure, incorporation of L-(/sup 35/S)Cys into each peptide was determined in hydrated and dehydrated rats. Label incorporation into arginine vasopressin and oxytocin in the hypothalamus and the neurohypophysis of dehydrated rats was 2-3 times greater than that in hydrated rats. Incorporation of label into hypothalamic and neurohypophyseal somatostatin was unaffected by the hydration state of the animal. This procedure thus provides a very rapid, but sensitive, set of techniques for studying the control of small peptide biosynthesis in the brain.

  6. Determination of trace labile copper in environmental waters by magnetic nanoparticle solid phase extraction and high-performance chelation ion chromatography.

    Science.gov (United States)

    Wei, Z; Sandron, S; Townsend, A T; Nesterenko, P N; Paull, B

    2015-04-01

    Cobalt magnetic nanoparticles surface functionalised with iminodiacetic acid were evaluated as a nano-particulate solid phase extraction absorbent for copper ions (Cu(2+)) from environmental water samples. Using an external magnetic field, the collector nanoparticles could be separated from the aqueous phase, and adsorbed ions simply decomplexed using dilute HNO3. Effects of pH, buffer concentration, sample and sorbent volume, extraction equilibrium time, and interfering ion concentration on extraction efficiency were investigated. Optimal conditions were then applied to the extraction of Cu(2+) ions from natural water samples, prior to their quantitation using high-performance chelation ion chromatography. The limits of detection (LOD) of the combined extraction and chromatographic method were ~0.1 ng ml(-1), based upon a 100-fold preconcentration factor (chromatographic performance; LOD=9.2 ng ml(-1) Cu(2+)), analytical linear range from 20 to 5000 ng mL(-1), and relative standard deviations=4.9% (c=1000 ng ml(-1), n=7). Accuracy and precision of the combined approach was verified using a certified reference standard estuarine water sample (SLEW-2) and comparison of sample determinations with sector field inductively coupled plasma mass spectrometry. Recoveries from the addition of Cu(2+) to impacted estuarine and rain water samples were 103.5% and 108.5%, respectively. Coastal seawater samples, both with and without prior UV irradiation and dissolved organic matter removal were also investigated using the new methodology. The effect of DOM concentration on copper availability was demonstrated. Copyright © 2015. Published by Elsevier B.V.

  7. Rapid and sensitive liquid chromatography-tandem mass spectrometry method for the quantitation of levodropropizine in human plasma.

    Science.gov (United States)

    Tang, Yunbiao; Zhao, Limei; Wang, Yingwu; Fawcett, J Paul; Gu, Jingkai

    2005-05-05

    A rapid and sensitive LC-MS-MS method for quantifying levodropropizine in human plasma after oral administration of a single-dose (60 mg/day) was developed and validated. The sample preparation used liquid-liquid extraction with a mixture of dichloromethane-diethyl ether (2:3, v/v) in a basic environment. The retention time of levodropropizne and zolmitriptan (used as internal standard) was 1.6 and 1.4 min, respectively. The assay was linear over the range 0.25-500 ng/mL with a LOQ of 0.25 ng/mL. The intra- and inter-day precision were levodropropizine concentration profile in human plasma was determined.

  8. Rapid determination by reversed-phase high-performance liquid chromatography of Vitamins A and E in infant formulas.

    Science.gov (United States)

    Rodas Mendoza, B; Morera Pons, S; Castellote Bargalló, A I; López-Sabater, M C

    2003-11-14

    A rapid, sensitive method has been developed for the simultaneous determination of retinol acetate, delta-, gamma-, alpha-tocopherol and alpha-tocopherol acetate. We compare two experimental procedures for simultaneous direct solvent extraction of these vitamins without previous saponification. Method I: the fat milk sample was extracted with ethanol-hexane and injected directly into the chromatographic column. Method II: the power milk sample was extracted with ethanol-hexane and also injected directly into the column. Under optimum conditions the limits of detection for retinol acetate, delta-, gamma-, alpha-tocopherol and alpha-tocopherol acetate were 0.33, 21.2, 32.9, 32.5 and 3.2 ng and the limits of quantification were 0.42, 25.3, 37.9, 36.8 and 6.3 ng, respectively. The precision results showed that the relative standard deviations of repeatability and reproducibility were between 0.74 and 5.7%.

  9. [Rapid determination of eight organic acids in plant tissue by sequential extraction and high performance liquid chromatography].

    Science.gov (United States)

    Huang, Tianzhi; Wang, Shijie; Liu Xiuming; Liu, Hong; Wu, Yanyou; Luo Xuqiang

    2014-12-01

    A sequential extraction method was developed to determine different forms of oxalate and seven oxalate-metabolism-related organic acids (glyoxylic acid, tartaric acid, glycolic acid, malic acid, acetic acid, citric acid, succinic acid) in plant tissue. The ultra-pure water was used as the extraction medium to obtain water-soluble oxalic acid and the other seven water-soluble organic acids. After the extraction of the water-soluble organic acids, the residues were extracted by dilute hydrochloric acid successively to get the acid-soluble oxalate which entered the liquid phase. A Hypersil ODS column was used with 5 mmol/L potassium dihydrogen phosphate buffer solution (pH 2. 8) as the mobile phase. The diode array detector was set at 210 nm and the column temperature at 30 °C with the injection volume of 5 µL. The flow rate was controlled at different times which allowed a good and rapid separation of the organic acids and hydrochloric acid. Under these conditions, the linear ranges of the method were 1-2000 mg/L for oxalic acid, 25-2,000 mg/L for acetic acid, and 10-2,000 mg/L for glyoxylic acid, tartaric acid, glycolic acid, malic acid, citric acid and succinic acid, with the correlation coefficients of the eight organic acids ≥ 0. 9996. The average recoveries of the eight organic acids in leaves and roots were 93. 5%-104. 4% and 85. 3%-105. 4% with RSDs of 0. 15% -2.43% and 0. 31%-2. 9% (n=7), respectively. The limits of detection ranged from 1 to 10 ng (S/N=3). The results indicated that the method is accurate, rapid and reproducible for the determination of organic acids in plant samples.

  10. Target-guided separation of Bougainvillea glabra betacyanins by direct coupling of preparative ion-pair high-speed countercurrent chromatography and electrospray ionization mass-spectrometry.

    Science.gov (United States)

    Jerz, Gerold; Wybraniec, Sławomir; Gebers, Nadine; Winterhalter, Peter

    2010-07-02

    In this study, preparative ion-pair high-speed countercurrent chromatography was directly coupled to an electrospray ionization mass-spectrometry device (IP-HSCCC/ESI-MS-MS) for target-guided fractionation of high molecular weight acyl-oligosaccharide linked betacyanins from purple bracts of Bougainvillea glabra (Nyctaginaceae). The direct identification of six principal acyl-oligosaccharide linked betacyanins in the mass range between m/z 859 and m/z 1359 was achieved by positive ESI-MS ionization and gave access to the genuine pigment profile already during the proceeding of the preparative separation. Inclusively, all MS/MS-fragmentation data were provided during the chromatographic run for a complete analysis of substitution pattern. On-line purity evaluation of the recovered fractions is of high value in target-guided screening procedures and for immediate decisions about suitable fractions used for further structural analysis. The applied preparative hyphenation was shown to be a versatile screening method for on-line monitoring of countercurrent chromatographic separations of polar crude pigment extracts and also traced some minor concentrated compounds. For the separation of 760mg crude pigment extract the biphasic solvent system tert.-butylmethylether/n-butanol/acetonitrile/water 2:2:1:5 (v/v/v/v) was used with addition of ion-pair forming reagent trifluoroacetic acid. The preparative HSCCC-eluate had to be modified by post-column addition of a make-up solvent stream containing formic acid to reduce ion-suppression caused by trifluoroacetic acid and later significantly maximized response of ESI-MS/MS detection of target substances. A variable low-pressure split-unit guided a micro-eluate to the ESI-MS-interface for sensitive and direct on-line detection, and the major volume of the effluent stream was directed to the fraction collector for preparative sample recovery. The applied make-up solvent mixture significantly improved smoothness of the continuously

  11. Quantification of Tetramethylenedisulfotetramine (TETS) in Various Food Matrices by Solid Phase Extraction Liquid ChromatographyIon Trap Mass Spectrometry

    Science.gov (United States)

    2017-04-01

    Agent Chemistry Team from the Research and Technology Directorate of the U.S. Army Edgewood Chemical Biological Center (ECBC; Aberdeen Proving...food and biological sample matrices has been achieved using gas chromatography coupled with mass spectrometry (GC–MS),6–10 and limited literature...were provided with one Adobe portable document format (pdf) electronic version of this report: U.S. Army Edgewood Chemical Biological Center

  12. Single column comprehensive analysis of pharmaceutical preparations using dual-injection mixed-mode (ion-exchange and reversed-phase) and hydrophilic interaction liquid chromatography.

    Science.gov (United States)

    Kazarian, Artaches A; Taylor, Mark R; Haddad, Paul R; Nesterenko, Pavel N; Paull, Brett

    2013-12-01

    The comprehensive separation and detection of hydrophobic and hydrophilic active pharmaceutical ingredients (APIs), their counter-ions (organic, inorganic) and excipients, using a single mixed-mode chromatographic column, and a dual injection approach is presented. Using a mixed-mode Thermo Fisher Acclaim Trinity P1 column, APIs, their counter-ions and possible de