WorldWideScience

Sample records for rapid gas chromatographic

  1. Dual liquid and gas chromatograph system

    Science.gov (United States)

    Gay, D.D.

    A chromatographic system is described that utilizes one detection system for gas chromatographic and micro-liquid chromatographic determinations. The detection system is a direct-current, atmospheric-pressure, helium plasma emission spectrometer. The detector utilizes a nontransparent plasma source unit which contains the plasma region and two side-arms which receive effluents from the micro-liquid chromatograph and the gas chromatograph. The dual nature of this chromatographic system offers: (1) extreme flexibility in the samples to be examined; (2) extreme low sensitivity; (3) element selectivity; (4) long-term stability; (5) direct correlation of data from the liquid and gas samples; (6) simpler operation than with individual liquid and gas chromatographs, each with different detection systems; and (7) cheaper than a commercial liquid chromatograph and a gas chromatograph.

  2. The gas-chromatographic and gas-chromatographic-mass-spectrometric identification of halogen-containing organic compounds

    Science.gov (United States)

    Gidaspov, B. V.; Zenkevich, I. G.; Rodin, A. A.

    1989-09-01

    The problem of identifying halogen-containing organic compounds in their gas-chromatographic and gas-chromatographic-mass-spectrometric (GC-MS) determination in different materials has been examined. Particular attention has been paid not to the complete characterisation of methods for carrying out this analysis but to the most important problem of increasing the selectivity at the stages of sampling, separation, and interpretation of the gas-chromatographic and GC-MS information. The bibliography contains 292 references.

  3. Optimization of the gas chromatographic separations

    International Nuclear Information System (INIS)

    Gasco Sanchez, L.

    1973-01-01

    A review and a critical study on the optimization of the gas chromatographic separations are made. After dealing with the fundamental gas chromatographic equations, some methods of expressing column performances are discussed: performance indices, performance parameters, resolution and effective plate number per unit time. This is completed with a comparative study on performances of various types of columns. Moreover, optimization methods for operating chromatographic conditions are extensively dealt with: as resolution optimization, separation time, and normalization techniques for the time of analysis in order to achieve the maximum resolution at constant time. Finally, some others non operating parameters such as: selectivity of stationary phases, column preparation and optimization methods by means of computers are studied. (Author) 68 refs

  4. A Gas Chromatographic System for the Detection of Ethylene Gas Using Ambient Air as a Carrier Gas.

    Science.gov (United States)

    Zaidi, Nayyer Abbas; Tahir, Muhammad Waseem; Vellekoop, Michael J; Lang, Walter

    2017-10-07

    Ethylene gas is a naturally occurring gas that has an influence on the shelf life of fruit during their transportation in cargo ships. An unintentional exposure of ethylene gas during transportation results in a loss of fruit. A gas chromatographic system is presented here for the detection of ethylene gas. The gas chromatographic system was assembled using a preconcentrator, a printed 3D printed gas chromatographic column, a humidity sensor, solenoid valves, and an electrochemical ethylene gas sensor. Ambient air was used as a carrier gas in the gas chromatographic system. The flow rate was fixed to 10 sccm. It was generated through a mini-pump connected in series with a mass flow controller. The metal oxide gas sensor is discussed with its limitation in ambient air. The results show the chromatogram obtained from metal oxide gas sensor has low stability, drifts, and has uncertain peaks, while the chromatogram from the electrochemical sensor is stable and precise. Furthermore, ethylene gas measurements at higher ppb concentration and at lower ppb concentration were demonstrated with the electrochemical ethylene gas sensor. The system separates ethylene gas and humidity. The chromatograms obtained from the system are stable, and the results are 1.2% repeatable in five similar measurements. The statistical calculation of the gas chromatographic system shows that a concentration of 2.3 ppb of ethylene gas can be detected through this system.

  5. A Small-Scale Low-Cost Gas Chromatograph

    Science.gov (United States)

    Gros, Natasa; Vrtacnik, Margareta

    2005-01-01

    The design and application of a small-scale portable gas chromatograph for learning of the basic concepts of chromatography is described. The apparatus consists of two basic separable units, which includes a chromatographic unit and an electronic unit.

  6. On-line gas chromatographic analysis of airborne particles

    Science.gov (United States)

    Hering, Susanne V [Berkeley, CA; Goldstein, Allen H [Orinda, CA

    2012-01-03

    A method and apparatus for the in-situ, chemical analysis of an aerosol. The method may include the steps of: collecting an aerosol; thermally desorbing the aerosol into a carrier gas to provide desorbed aerosol material; transporting the desorbed aerosol material onto the head of a gas chromatography column; analyzing the aerosol material using a gas chromatograph, and quantizing the aerosol material as it evolves from the gas chromatography column. The apparatus includes a collection and thermal desorption cell, a gas chromatograph including a gas chromatography column, heated transport lines coupling the cell and the column; and a quantization detector for aerosol material evolving from the gas chromatography column.

  7. Gas-Chromatographic Determination Of Water In Freon PCA

    Science.gov (United States)

    Melton, Donald M.

    1994-01-01

    Gas-chromatographic apparatus measures small concentrations of water in specimens of Freon PCA. Testing by use of apparatus faster and provides greater protection against accidental contamination of specimens by water in testing environment. Automated for unattended operation. Also used to measure water contents of materials, other than Freon PCA. Innovation extended to development of purgeable sampling accessory for gas chromatographs.

  8. Gas chromatographic determination of calcium propionate added as preservative to bread.

    Science.gov (United States)

    Lamkin, W M; Unruh, N C; Pomeranz, Y

    1987-01-01

    A simple and rapid gas chromatographic procedure was developed for determining low concentrations of propionate added as a preservative to bread. A bread sample to be analyzed was ground in a meat grinder with a 3 mm hole plate and finely divided by rubbing through a No. 8 sieve. The propionate was then extracted into 0.050M formic acid in a blender at low speed for 5 min, and an aliquot of a filtrate was analyzed directly by gas chromatography. Chromatographic separation was accomplished on a Carbopack C column coated with 0.3% (w/w) Carbowax 20M and 0.1% (w/w) phosphoric acid. Less than 0.2 ppm propionic acid could be detected in the aqueous extract. Over the range of 0.03-0.23% calcium propionate, average relative error was -1.20% with an average coefficient of variation of 2.02%.

  9. Gas-chromatographic separation of hydrogen isotopic mixtures

    International Nuclear Information System (INIS)

    Preda, Anisoara; Bidica, Nicolae

    2005-01-01

    Full text: Gas chromatographic separation of hydrogen isotopes have been reported in the literature since late of 1950's. Gas chromatography is primarily an analytical method, but because of its properties it may be used in many other fields with excellent results. A simple method is proposed for the gas-chromatographic analysis of complex gas mixtures containing hydrogen isotopes; the method is based on the substantial difference in the thermal conductivity of these isotopes. One of the main disadvantages of the conventional gas chromatography is the long retention times required for the analysis of hydrogen gas mixtures while the column is operated at very low temperature. The method described in this paper was based on using a capillary molecular sieve 5A column operated for this kind of separation at 173 K. The carrier gas was Ne and the detector was TCD. In the paper chromatograms for various carrier flow rates and various hydrogen isotope mixtures are presented. (authors)

  10. Temperature Control of Gas Chromatograph Based on Switched Delayed System Techniques

    Directory of Open Access Journals (Sweden)

    Xiao-Liang Wang

    2014-01-01

    Full Text Available We address the temperature control problem of the gas chromatograph. We model the temperature control system of the gas chromatograph into a switched delayed system and analyze the stability by common Lyapunov functional technique. The PI controller parameters can be given based on the proposed linear matrix inequalities (LMIs condition and the designed controller can make the temperature of gas chromatograph track the reference signal asymptotically. An experiment is given to illustrate the effectiveness of the stability criterion.

  11. A Quantitative Gas Chromatographic Ethanol Determination.

    Science.gov (United States)

    Leary, James J.

    1983-01-01

    Describes a gas chromatographic experiment for the quantitative determination of volume percent ethanol in water ethanol solutions. Background information, procedures, and typical results are included. Accuracy and precision of results are both on the order of two percent. (JN)

  12. Rapid and sensitive determination of deuterium concentration by gas chromatography

    International Nuclear Information System (INIS)

    Takahashi, Tomiki; Ohokoshi, Sumio; Shinriki, Nariko; Sato, Toshio

    1984-01-01

    Gas chromatographic determination of hydrogen isotopes D 2 and HD has hitherto been carried out with a molecular sieve column kept at -195 0 C under the H 2 carrier gas. However, the amount of D 2 in hydrogen gas containing low HD concentration of less than 5 % can be practically neglected judging from the equilibrium constant of H 2 -D 2 exchange reaction. Therefore, there is no need to separate HD from D 2 . As an improvement, in this paper, the gas chromatographic determination of HD in low concentration ( 2 as a carrier gas enabled us to enhance the cell current of TCD drastically, hence gave rise to high sensitivity of HD detection. The limit of determination of the concentration of HD was 0.01%. In the case of the higher concentration (>5%) of HD in hydrogen gas, D 2 and HD have been separated and determined by the method described above, but this method takes more than ten minutes. Therefore, we designed a new gas chromatographic analysis of the HD-D 2 mixture with an activated alumina column at -195 0 C under the H 2 carrier gas (330 ml/min). The advantages of this method are in (1) rapid analysis (in 1 min), (2) no need of the rigid activation temperature ((110--250) 0 C), (3) no change of the relative molar sensitivity of HD to D 2 at the various flow rates of H 2 carrier gas ((100--300)ml/min). (author)

  13. A Gas Chromatographic Method for the Determination of Bicarbonate and Dissolved Gases

    Directory of Open Access Journals (Sweden)

    John H. Loughrin

    2017-11-01

    Full Text Available A gas chromatographic method for the rapid determination of aqueous carbon dioxide and its speciation into solvated carbon dioxide and bicarbonate is presented. One-half mL samples are injected through a rubber septum into 20-mL vials that are filled with 9.5 mL of 0.1 N HCl. A one mL portion of the headspace is withdrawn and injected onto a gas chromatograph equipped with a thermal conductivity detector. Using the dimensionless Henry's constant for carbon dioxide and an adaptation of the Henderson-Hasselbalch equation, carbon dioxide in the samples can be categorized among solvated, bicarbonate, and carbonate forms. Natural water samples as well as wastewater from a municipal sewage treatment plant and a swine rearing operation were analyzed by this method and the results compared favorably to those obtained by titration. Samples stored for up to 5 weeks showed no significant changes in carbon dioxide concentrations. In addition, using flame ionization and electron capture detectors, methane and nitrous oxide concentrations in the samples were also measured.

  14. Headspace gas chromatographic method for the measurement of difluoroethane in blood.

    Science.gov (United States)

    Broussard, L A; Broussard, A; Pittman, T; Lafferty, D; Presley, L

    2001-01-01

    To develop a gas chromatographic assay for the analysis of difluoroethane, a volatile substance, in blood and to determine assay characteristics including linearity, limit of quantitation, precision, and specificity. Referral toxicology laboratory Difluoroethane, a colorless, odorless, highly flammable gas used as a refrigerant blend component and aerosol propellant, may be abused via inhalation. A headspace gas chromatographic procedure for the identification and quantitation of difluoroethane in blood is presented. A methanolic stock standard prepared from pure gaseous difluoroethane was used to prepare whole blood calibrators. Quantitation of difluoroethane was performed using a six-point calibration curve and an internal standard of 1-propanol. The assay is linear from 0 to 115 mg/L including a low calibrator at 4 mg/L, the limit of quantitation. Within-run coefficients of variation at mean concentrations of 13.8 mg/L and 38.5 mg/L were 5.8% and 6.8% respectively. Between-run coefficients of variation at mean concentrations of 15.9 mg/L and 45.7 mg/L were 13.4% and 9.8% respectively. Several volatile substances were tested as potential interfering compounds with propane having a retention time identical to that of difluoroethane. This method requires minimal sample preparation, is rapid and reproducible, can be modified for the quantitation of other volatiles, and could be automated using an automatic sampler/injector system.

  15. The behaviour of radionuclides in gas adsorption chromatographic processes with superimposed chemical reactions (chlorides)

    International Nuclear Information System (INIS)

    Eichler, B.

    1996-01-01

    Thermochemical relationships are derived describing the gas adsorption chromatographic transport of carrier-free radionuclides. Especially, complex adsorption processes such as dissociative, associative and substitutive adsorption are dealt with. The comparison of experimental with calculated data allows the determination of the type of adsorption reaction, which is the basis of the respective gas chromatographic process. The behaviour of carrier-free radionuclides of elements Pu, Ce, Ru, Co and Cr in thermochromatographic experiments with chlorinating carrier gases can be described as dissociative adsorption of chlorides in higher oxidation states. The gas adsorption chromatographic transport of Zr with oxygen and chlorine containing carrier gas is shown to be a substitutive adsorption process. The consequences of superimposed chemical reactions on the interpretation of results and the conception of gas adsorption chromatographic experiments with carrier-free radionuclides in isothermal columns and in temperature gradient tubes is discussed. (orig.)

  16. Research on technology of online gas chromatograph for SF6 decomposition products

    Science.gov (United States)

    Li, L.; Fan, X. P.; Zhou, Y. Y.; Tang, N.; Zou, Z. L.; Liu, M. Z.; Huang, G. J.

    2017-12-01

    Sulfur hexafluoride (SF6) decomposition products were qualitatively and quantitatively analyzed by several gas chromatographs in the laboratory. Test conditions and methods were selected and optimized to minimize and eliminate the SF6’ influences on detection of other trace components. The effective separation and detection of selected characteristic gases were achieved. And by comparison among different types of gas chromatograph, it was found that GPTR-S101 can effectively separate and detect SF6 decomposition products and has best the best detection limit and sensitivity. On the basis of GPTR-S101, online gas chromatograph for SF6decomposition products (GPTR-S201) was developed. It lays the foundation for further online monitoring and diagnosis of SF6.

  17. Gas chromatographic determination of impurities of inorganic compounds

    International Nuclear Information System (INIS)

    Drugov, Yu.S.

    1985-01-01

    Methods of concentration, separation, detection in gas chromatographic determination of impurities of inorganic compounds including low-boiling gases, reactive gases, organometallic compounds, free metals, anions, etc. are reviewed. Methods of reaction gas chromatography for determining reactive gases, water, anions, metal chelates are considered in detail as well as methods of reaction-sorption concentration and reaction gas extraction. The application of gas chromatograpny ior anaiysis of water and atmosphere contamination, for determination of impurities in highly pure solid substances and gases is described

  18. GAS CHROMATOGRAPHIC AND SPECTROSCOPIC ANALYSIS OF ...

    African Journals Online (AJOL)

    Peroxyformic acid prepared in-situ was employed for epoxidation of canola oil in the presence of toluene. Gas chromatographic analysis of the product revealed the following species: C16:0; C18:0; C18:1; C18:2; C18:3; monoepoxy C18:0; monoepoxy C18:1; monoepoxy C18:2; diepoxy C18:0; diepoxy C18:1 and triepoxy ...

  19. Evaluation of pesticide adsorption in gas chromatographic injector and column

    Directory of Open Access Journals (Sweden)

    Gevany Paulino de Pinho

    2012-01-01

    Full Text Available Components in complex matrices can cause variations in chromatographic response during analysis of pesticides by gas chromatography. These variations are related to the competition between analytes and matrix components for adsorption sites in the chromatographic system. The capacity of the pesticides chlorpyrifos and deltamethrin to be adsorbed in the injector and chromatographic column was evaluated by constructing three isotherms and changing the column heating rate to 10 and 30 ºC min-1. By using ANCOVA to compare the slope of calibration graphs, results showed that the higher the injector temperature (310 ºC the lower the pesticide adsorption. Also, deltamethrin influenced the adsorption of chlorpyrifos on the column chromatographic.

  20. Development and evaluation of a gas chromatographic method for the determination of triazine herbicides in natural water samples

    Science.gov (United States)

    Steinheimer, T.R.; Brooks, M.G.

    1984-01-01

    A multi-residue method is described for the determination of triazine herbicides in natural water samples. The technique uses solvent extraction followed by gas chromatographic separation and detection employing nitrogen-selective devices. Seven compounds can be determined simultaneously at a nominal detection limit of 0.1 ??g/L in a 1-litre sample. Three different natural water samples were used for error analysis via evaluation of recovery efficiencies and estimation of overall method precision. As an alternative to liquid-liquid partition (solvent extraction) for removal of compounds of interest from water, solid-phase extraction (SPE) techniques employing chromatographic grade silicas with chemically modified surfaces have been examined. SPE is found to provide rapid and efficient concentration with quantitative recovery of some triazine herbicides from natural water samples. Concentration factors of 500 to 1000 times are obtained readily by the SPE technique.A multi-residue method is described for the determination of triazine herbicides in natural water samples. The technique uses solvent extraction followed by gas chromatographic separation and detection employing nitrogen-selective devices. Seven compounds can be determined simultaneously at a nominal detection limit of 0. 1 mu g/L in a 1-litre sample. As an alternative to liquid-liquid partition (solvent extraction) for removal of compounds of interest from water, solid-phase extraction (SPE) techniques employing chromatographic grade silicas with chemically modified surfaces have been examined. SPE is found to provide rapid and efficient concentration with quantitative recovery of some triazine herbicides from natural water samples. Concentration factors of 500 to 1000 times are obtained readily by the SPE technique.

  1. A rapid gas chromatographic injection-port derivatization method for the tandem mass spectrometric determination of patulin and 5-hydroxymethylfurfural in fruit juices.

    Science.gov (United States)

    Marsol-Vall, Alexis; Balcells, Mercè; Eras, Jordi; Canela-Garayoa, Ramon

    2016-07-01

    A novel method consisting of injection-port derivatization coupled to gas chromatography-tandem mass spectrometry is described. The method allows the rapid assessment of 5-hydroxymethylfurfural (HMF) and patulin content in apple and pear derivatives. The chromatographic separation of the compounds was achieved in a short chromatographic run (12.2min) suitable for routine controls of these compounds in the fruit juice industry. The optimal conditions for the injection-port derivatization were at 270°C, 0.5min purge-off, and a 1:2 sample:derivatization reagent ratio (v/v). These conditions represent an important saving in terms of derivatization reagent consumption and sample preparation time. Quality parameters were assessed for the target compounds, giving LOD of 0.7 and 1.6μg/kg and LOQ of 2 and 5μg/kg for patulin and HMF, respectively. These values are below the maximum patulin concentration in food products intended for infants and young children. Repeatability (%RSD n=5) was below 12% for both compounds. In addition, the method linearity ranged between 25 and 1000μg/kg and between 5 and 192μg/kg for HMF and patulin, respectively. Finally, the method was applied to study HMF and patulin content in various fruit juice samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Determination of hexachlorocyclohexane pesticide residues in wool fat by a combined high-performance liquid chromatographic-gas-liquid chromatographic method

    International Nuclear Information System (INIS)

    Ali, S.L.

    1978-01-01

    Beta- and gamma-hexachlorocyclohexane residues were determined in twelve wool fat samples by using a combined high-performance liquid chromatographic (HPLC)-gas-liquid chromatographic (GLC) method. After extraction and chromatographic clean-up on a silca-gel column, the sample was further purified by HPLC on a reversed-phase C-18 column with methanol as the mobile phase. The final determination was effected by GLC with a 1-mCi nickel-63 electron-capture detector. The analytical method was checked by addition of carbon-14-labelled lindane and measurement of the radioactivity in a liquid scintillation counter. (Auth.)

  3. A gas/liquid chromatographic-mass spectrometric method for the rapid screening of 250 pesticides in aqueous matrices

    Energy Technology Data Exchange (ETDEWEB)

    Chandramouli, B.; Harvan, D.; Brittain, S.; Hass, R. [Eno River Labs, LLC. Durham, NC (United States)

    2004-09-15

    Pesticide residues in food present a potentially serious and significant cause for concern. Many pesticides have been associated with significant health effects to the nervous and endocrine systems and some have been deemed carcinogenic. There are many well-established techniques for pesticide analysis. However, commercial pesticide methods have traditionally only been available for specific pesticide families, such as chlorinated pesticides or herbicides, and at detection limits ranging from 0.05 ppb to 1 ppm in aqueous matrices. Techniques that can quickly screen for the presence/absence of pesticide residues in food matrices are critical in ensuring the safety of food and water. This paper outlines a combined Gas Chromatographic-High Resolution Mass Spectrometric (GC-HRMS) and Liquid Chromatographic Tandem Mass Spectrometric (LC-MS/MS) screening assay for 250 pesticides that was developed for use in water, and soda samples at screening levels ranging from 0.1-5 ppb. The pesticides selected have been identified by the European Union as being of concern and the target of possible legislation. The list encompasses a variety of pesticide classes and compound groupings.

  4. Direct coupling of a dense (supercritical) gas chromatograph to a mass spectrometer using a supersonic molecular beam interface

    International Nuclear Information System (INIS)

    Randall, L.G.; Wahrhaftig, A.L.

    1981-01-01

    A detecting mass spectrometer has been successfully coupled to a dense gas (supercritical fluid) chromatograph to produce an instrument (DGC/MS) that may be an alternative to high performance liquid chromatograph/mass spectrometer instruments (HPLC/MS) and gas chromatograph/mass spectrometer instruments (GC/MS) for analysis of involatile and/or thermally labile compounds. The mobile phase in DGC is a gas held at temperatures above the critical temperature and at pressures sufficient to obtain nearly liquid-like densities. DGC combines advantages of GC and HPLC: rapid separations, moderate operating temperatures, and analysis of involatile compounds. An advantage unique to DGC is the solvent power dependence upon pressure. While several groups have studied DGC, its development has been limited by the lack of a sensitive and selective detector. Hence, work has been directed towards the design and construction of a DGC/MS resulting in a trial instrument capable of chromatographic pressures of at least 300 atm and temperatures from 10 0 to 60 0 C. The DGC/MS coupling has been accomplished by the use of a supersonic molecular beam interface. This application of molecular beam formation appears to be unique in its requirements of a large pressure ratio (approx.10 8 ), low flow rates, and low final pressures. The authors outline characteristics of supersonic jets and molecular beams pertinent to the design of such an instrument. The interface which uses pumping speeds of 2400 and 1200 l/s in the beam forming chambers is described in detail, while the other components: the detecting mass spectrometer, the dense gas supply, and the DGC: are briefly described. Preliminary work with this instrument has established the feasibility of DGC/MS as an analytical technique and further development is recommended

  5. Measurement of water absorption capacity in wheat flour by a headspace gas chromatographic technique.

    Science.gov (United States)

    Xie, Wei-Qi; Yu, Kong-Xian; Gong, Yi-Xian

    2018-04-17

    The purpose of this work is to introduce a new method for quantitatively analyzing water absorption capacity in wheat flour by a headspace gas chromatographic technique. This headspace gas chromatographic technique was based on measuring the water vapor released from a series of wheat flour samples with different contents of water addition. According to the different trends between the vapor and wheat flour phase before and after the water absorption capacity in wheat flour, a turning point (corresponding to water absorption capacity in wheat flour) can be obtained by fitting the data of the water gas chromatography peak area from different wheat flour samples. The data showed that the phase equilibrium in the vial can be achieved in 25 min at desired temperature (35°C). The relative standard deviation of the reaction headspace gas chromatographic technique in water absorption capacity determination was within 3.48%, the relative differences has been determined by comparing the water absorption capacity obtained from this new analytical technique with the data from the reference technique (i.e., the filtration method), which are less than 8.92%. The new headspace gas chromatographic method is automated, accurate and be a reliable tool for quantifying water absorption capacity in wheat flour in both laboratory research and mill applications. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Mars Solar Balloon Landed Gas Chromatograph Mass Spectrometer

    Science.gov (United States)

    Mahaffy, P.; Harpold, D.; Niemann, H.; Atreya, S.; Gorevan, S.; Israel, G.; Bertaux, J. L.; Jones, J.; Owen, T.; Raulin, F.

    1999-01-01

    A Mars surface lander Gas Chromatograph Mass Spectrometer (GCMS) is described to measure the chemical composition of abundant and trace volatile species and isotope ratios for noble gases and other elements. These measurements are relevant to the study of atmospheric evolution and past climatic conditions. A Micromission plan is under study where a surface package including a miniaturized GCMS would be delivered to the surface by a solar heated hot air balloon based system. The balloon system would be deployed about 8 km above the surface of Mars, wherein it would rapidly fill with Martian atmosphere and be heated quickly by the sun. The combined buoyancy and parachuting effects of the solar balloon result in a surface package impact of about 5 m/sec. After delivery of the package to the surface, the balloon would ascend to about 4 km altitude, with imaging and magnetometry data being taken for the remainder of the daylight hours as the balloon is blown with the Martian winds. Total atmospheric entry mass of this mission is estimated to be approximately 50 kg, and it can fit as an Ariane 5 piggyback payload. The GCMS would obtain samples directly from the atmosphere at the surface and also from gases evolved from solid phase material collected from well below the surface with a Sample Acquisition and Transport Mechanism (SATM). The experiment envisioned in the Mars Micromission described would obtain samples from a much greater depth of up to one meter below the surface, and would search for organic molecules trapped in ancient stratified layers well below the oxidized surface. Insitu instruments on upcoming NASA missions working in concert with remote sensing measurement techniques have the potential to provide a more detailed investigation of mineralogy and the extent of simple volatiles such as CO2 and H2O in surface and subsurface solid phase materials. Within the context of subsequent mission opportunities such as those provided by the Ariane 5 piggyback

  7. Optimization of the gas chromatographic separations; Optimacion de las separaciones cromatograficas en fase gaseosa

    Energy Technology Data Exchange (ETDEWEB)

    Gasco Sanchez, L

    1973-07-01

    A review and a critical study on the optimization of the gas chromatographic separations are made. After dealing with the fundamental gas chromatographic equations, some methods of expressing column performances are discussed: performance indices, performance parameters, resolution and effective plate number per unit time. This is completed with a comparative study on performances of various types of columns. Moreover, optimization methods for operating chromatographic conditions are extensively dealt with: as resolution optimization, separation time, and normalization techniques for the time of analysis in order to achieve the maximum resolution at constant time. Finally, some others non operating parameters such as: selectivity of stationary phases, column preparation and optimization methods by means of computers are studied. (Author) 68 refs.

  8. Comparison of two validated gas-chromatographic methods for the determination of trihalomethanes in drinking water Comparação de dois métodos cromatográficos validados para a dosagem de trialometanos em água potável

    OpenAIRE

    Maria Yumiko Tominaga; Antonio Flavio Mídio

    2003-01-01

    In this paper the results obtained using two validated gas-chromatographic procedures on drinking water for the determination of trihalomethanes are compared. The volatile compounds, chloroform (CF), bromodichloromethane (BDCM), dibromochloromethane (DBCM) and bromoform (BF) were detected by purge and trap capillary column gas-chromatography with electrolytic conductivity detector ( ELCD) and the simple and rapid gas-chromatographic method by electron capture detector (ECD) after liquid-liqui...

  9. Chromatographic measurement of hydrogen isotopic and permanent gas impurities in tritium

    International Nuclear Information System (INIS)

    Warner, D.K.; Kinard, C.; Bohl, D.C.

    1976-01-01

    This paper describes a gas chromatograph that was designed for dedicated analysis of hydrogen isotopic and permanent gas impurities in tritium and tritium-deuterium mixtures. The instrument that was developed substantially improved the accuracy and precision of hydrogen isotopic analysis in the 20 ppM to one mole percent range as compared with other analytical methods. Several unique design features of the instrument were required due to the radiation and isotopic exchange properties of the tritium in the samples; descriptions of these features are presented along with details of the complete chromatographic system. The experimental procedures used to calibrate the detector and statistically evaluate its performance are given, and the sources of analytical error are cited. The limitations of the present system are also discussed

  10. Pyrolysis gas chromatographic atomic emission detection for sediments, coals and other petrochemical precursors

    Energy Technology Data Exchange (ETDEWEB)

    Seeley, J.A.; Zeng, Y.D.; Uden, P.C.; Eglinton, T.I.; Ericson, I. (Massachusetts University, Amherst, MA (USA). Dept. of Chemistry)

    1992-09-01

    On-line flash pyrolysis coupled to a capillary gas chromatograph for the characterization of marine sediments, coals and other heterogeneous solid samples is described. A helium microwave-induced plasma is used for chromatographic detection by atomic emission spectrometry. Simultaneous multi-element detection is achieved with a photodiode array detector. The optical path of the gas chromatographic atomic emission detector is purged with helium, allowing simultaneous, sensitive detection of atomic emission from sulfur 181 nm, phosphorous 186 nm, arsenic 189 nm, selenium 196 nm and carbon 193 nm. Several sediment and coal samples have been analysed for their carbon, nitrogen, sulfur, oxygen, phosphorous, arsenic and selenium content. Qualitative information indicating the occurrence and distribution of these elements in the samples can be used to gauge the relative stage of diagenetic evolution of the samples and provide information on their depositional environment. In some instances the chromatographic behaviour of the compounds produced upon pyrolysis is improved through on-line alkylation. This on-line derivatization is achieved by adding liquid reagents to the pyrolysis probe or by adding liquid reagents to the pyrolysis probe or by adding solid reagents either to the solid sample or by packing the reagent in the injection port of the chromatograph.

  11. Separation and determination of high-carbon alcohols using method of column chromatographic and gas-chromatographic analysis

    International Nuclear Information System (INIS)

    Kang Zhongrong; Li Biping; Zeng Yongchang

    1988-01-01

    This paper describes the separation and determination of high-carbon alcohols from amine extractant by using the method of column chromatography of aluminium oxide and gas-chromatographic analysis. The total conent of high-carbon alcohols is determined by the method of column chromatography, while the components of the high-carbon alcohols and their relative contents are determined by the method of gas-chromatography. A simple reliable and practical method is provided for the analysis of high-carbon alcohol from the amine extractant in this paper

  12. Gas chromatographic analysis of simmondsins and simmondsin ferulates in jojoba meal.

    Science.gov (United States)

    Van Boven, M; Holser, R; Cokelaere, M; Flo, G; Decuypere, E

    2000-09-01

    A capillary gas chromatographic method was developed for the simultaneous determination of simmondsins and simmondsin ferulates in jojoba meal, in detoxified jojoba meal, in jojoba meal extracts, and in animal food mixtures.

  13. Simple gas chromatographic method for furfural analysis.

    Science.gov (United States)

    Gaspar, Elvira M S M; Lopes, João F

    2009-04-03

    A new, simple, gas chromatographic method was developed for the direct analysis of 5-hydroxymethylfurfural (5-HMF), 2-furfural (2-F) and 5-methylfurfural (5-MF) in liquid and water soluble foods, using direct immersion SPME coupled to GC-FID and/or GC-TOF-MS. The fiber (DVB/CAR/PDMS) conditions were optimized: pH effect, temperature, adsorption and desorption times. The method is simple and accurate (RSDfurfurals will contribute to characterise and quantify their presence in the human diet.

  14. A technique for rapid source apportionment applied to ambient organic aerosol measurements from a thermal desorption aerosol gas chromatograph (TAG

    Directory of Open Access Journals (Sweden)

    Y. Zhang

    2016-11-01

    Full Text Available We present a rapid method for apportioning the sources of atmospheric organic aerosol composition measured by gas chromatography–mass spectrometry methods. Here, we specifically apply this new analysis method to data acquired on a thermal desorption aerosol gas chromatograph (TAG system. Gas chromatograms are divided by retention time into evenly spaced bins, within which the mass spectra are summed. A previous chromatogram binning method was introduced for the purpose of chromatogram structure deconvolution (e.g., major compound classes (Zhang et al., 2014. Here we extend the method development for the specific purpose of determining aerosol samples' sources. Chromatogram bins are arranged into an input data matrix for positive matrix factorization (PMF, where the sample number is the row dimension and the mass-spectra-resolved eluting time intervals (bins are the column dimension. Then two-dimensional PMF can effectively do three-dimensional factorization on the three-dimensional TAG mass spectra data. The retention time shift of the chromatogram is corrected by applying the median values of the different peaks' shifts. Bin width affects chemical resolution but does not affect PMF retrieval of the sources' time variations for low-factor solutions. A bin width smaller than the maximum retention shift among all samples requires retention time shift correction. A six-factor PMF comparison among aerosol mass spectrometry (AMS, TAG binning, and conventional TAG compound integration methods shows that the TAG binning method performs similarly to the integration method. However, the new binning method incorporates the entirety of the data set and requires significantly less pre-processing of the data than conventional single compound identification and integration. In addition, while a fraction of the most oxygenated aerosol does not elute through an underivatized TAG analysis, the TAG binning method does have the ability to achieve molecular level

  15. Gas chromatographic column for the Viking 1975 molecular analysis experiment

    Science.gov (United States)

    Novotny, M.; Hayes, J. M.; Bruner, F.; Simmonds, P. G.

    1975-01-01

    A gas chromatographic column has been developed for use in the remote analysis of the Martian surface. The column, which utilizes a liquid-modified organic adsorbent (Tenax) as the stationary phase, provides efficient transmission and resolution of nanogram quantities of organic materials in the presence of millionfold excesses of water and carbon dioxide.

  16. An integrated methodological approach to the computer-assisted gas chromatographic screening of basic drugs in biological fluids using nitrogen selective detection.

    Science.gov (United States)

    Dugal, R; Massé, R; Sanchez, G; Bertrand, M J

    1980-01-01

    This paper presents the methodological aspects of a computerized system for the gas-chromatographic screening and primary identification of central nervous system stimulants and narcotic analgesics (including some of their respective metabolites) extracted from urine. The operating conditions of a selective nitrogen detector for optimized analytical functions are discussed, particularly the effect of carrier and fuel gas on the detector's sensitivity to nitrogen-containing molecules and discriminating performance toward biological matrix interferences. Application of simple extraction techniques, combined with rapid derivatization procedures, computer data acquisition, and reduction of chromatographic data are presented. Results show that this system approach allows for the screening of several drugs and their metabolites in a short amount of time. The reliability and stability of the system have been tested by analyzing several thousand samples for doping control at major international sporting events and for monitoring drug intake in addicts participating in a rehabilitation program. Results indicate that these techniques can be used and adapted to many different analytical toxicology situations.

  17. Detection of irradiated fruits and vegetables by gas-chromatographic methods and electron spin-resonance

    Energy Technology Data Exchange (ETDEWEB)

    Farag, S.E.A. (National Centre for Radiation Research and Technology, Cairo (Egypt))

    1993-01-01

    Gas chromatographic methods detected some hydrocarbons esp. 17:1, 16:2, 15:0 and 14:1 in irradiated, Avocado, Papaya, Mangoes with 0.75, 1.5, 3.0 kGy and Apricot with 0.5 and 3.0 kGy. The detection of hydrocarbons was clearly at high doses but the low doses need more sensitive conditions using Liquid-Liquid-Gas chromatographic method as used here. Using Electron Spin-Resonance, produce a specific signal from irradiated onion (dried leaves) as well as apricot (hard coat of kernels) after some weeks of irradiation process but not clear with the other foodstuffs. (orig.)

  18. Multiplex gas chromatography: an alternative concept for gas chromatographic analysis of planetary atmospheres

    Science.gov (United States)

    Valentin, J. R.

    1989-01-01

    Gas chromatography (GC) is a powerful technique for analyzing gaseous mixtures. Applied to the earth's atmosphere, GC can be used to determine the permanent gases--such as carbon dioxide, nitrogen, and oxygen--and to analyze organic pollutants in air. The U.S. National Aeronautics and Space Administration (NASA) has used GC in spacecraft missions to Mars (the Viking Biology Gas Exchange Experiment [GEX] and the Viking Gas Chromatograph-Mass Spectrometer [GC-MS]) and to Venus (the Pioneer Venus Gas Chromatograph [PVGC] on board the Pioneer Venus sounder probe) for determining the atmospheric constituents of these two planets. Even though conventional GC was very useful in the Viking and Pioneer missions, spacecraft constraints and limitations intrinsic to the technique prevented the collection of more samples. With the Venus probe, for instance, each measurement took a relatively long time to complete (10 min), and successive samples could not be introduced until the previous samples had left the column. Therefore, while the probe descended through the Venusian atmosphere, only three samples were acquired at widely separated altitudes. With the Viking mission, the sampling rate was not a serious problem because samples were acquired over a period of one year. However, the detection limit was a major disadvantage. The GC-MS could not detect simple hydrocarbons and simple alcohols below 0.1 ppm, and the GEX could not detect them below 1 ppm. For more complex molecules, the detection limits were at the parts-per-billion level for both instruments. Finally, in both the Viking and Pioneer missions, the relatively slow rate of data acquisition limited the number of analyses, and consequently, the amount of information returned. Similar constraints are expected in future NASA missions. For instance, gas chromatographic instrumentation is being developed to collect and analyze organic gases and aerosols in the atmosphere of Titan (one of Saturn's satellites). The Titan

  19. Development of new process network for gas chromatograph and analyzers connected with SCADA system and Digital Control Computers at Cernavoda NPP Unit 1

    International Nuclear Information System (INIS)

    Deneanu, Cornel; Popa Nemoiu, Dragos; Nica, Dana; Bucur, Cosmin

    2007-01-01

    The continuous monitoring of gas mixture concentrations (deuterium/ hydrogen/oxygen/nitrogen) accumulated in 'Moderator Cover Gas', 'Liquid Control Zone' and 'Heat Transport D 2 O Storage Tank Cover Gas', as well as the continuous monitoring of Heavy Water into Light Water concentration in 'Boilers Steam', 'Boilers Blown Down', 'Moderator heat exchangers', and 'Recirculated Water System', sensing any leaks of Cernavoda NPP U1 led to requirement of developing a new process network for gas chromatograph and analyzers connected to the SCADA system and Digital Control Computers of Cernavoda NPP Unit 1. In 2005 it was designed and implemented the process network for gas chromatograph which connected the gas chromatograph equipment to the SCADA system and Digital Control Computers of the Cernavoda NPP Unit 1. Later this process network for gas chromatograph has been extended to connect the AE13 and AE14 Fourier Transform Infrared (FTIR) analyzers with either. The Gas Chromatograph equipment measures with best accuracy the mixture gases (deuterium/ hydrogen/oxygen/nitrogen) concentration. The Fourier Transform Infrared (FTIR) AE13 and AE14 Analyzers measure the Heavy Water into Light Water concentration in Boilers Steam, Boilers BlownDown, Moderator heat exchangers, and Recirculated Water System, monitoring and signaling any leaks. The Gas Chromatograph equipment and Fourier Transform Infrared (FTIR) AE13 and AE14 Analyzers use the new OPC (Object Link Embedded for Process Control) technologies available in ABB's VistaNet network for interoperability with automation equipment. This new process network has interconnected the ABB chromatograph and Fourier Transform Infrared analyzers with plant Digital Control Computers using new technology. The result was an increased reliability and capability for inspection and improved system safety

  20. Gas chromatographic isolation technique for compound-specific radiocarbon analysis

    International Nuclear Information System (INIS)

    Uchida, M.; Kumamoto, Y.; Shibata, Y.; Yoneda, M.; Morita, M.; Kawamura, K.

    2002-01-01

    Full text: We present here a gas chromatographic isolation technique for the compound-specific radiocarbon analysis of biomarkers from the marine sediments. The biomarkers of fatty acids, hydrocarbon and sterols were isolated with enough amount for radiocarbon analysis using a preparative capillary gas chromatograph (PCGC) system. The PCGC systems used here is composed of an HP 6890 GC with FID, a cooled injection system (CIS, Gerstel, Germany), a zero-dead-volume effluent splitter, and a cryogenic preparative collection device (PFC, Gerstel). For AMS analysis, we need to separate and recover sufficient quantity of target individual compounds (>50 μgC). Yields of target compounds from C 14 n-alkanes to C 40 to C 30 n-alkanes and approximately that of 80% for higher molecular weights compounds more than C 30 n-alkanes. Compound specific radiocarbon analysis of organic compounds, as well as compound-specific stable isotope analysis, provide valuable information on the origins and carbon cycling in marine system. Above PCGC conditions, we applied compound-specific radiocarbon analysis to the marine sediments from western north Pacific, which showed the possibility of a useful chronology tool for estimating the age of sediment using organic matter in paleoceanographic study, in the area where enough amounts of planktonic foraminifera for radiocarbon analysis by accelerator mass spectrometry (AMS) are difficult to obtain due to dissolution of calcium carbonate. (author)

  1. Determination of trihalomethanes in waters by ionic liquid-based single drop microextraction/gas chromatographic/mass spectrometry.

    Science.gov (United States)

    Aguilera-Herrador, Eva; Lucena, Rafael; Cárdenas, Soledad; Valcárcel, Miguel

    2008-10-31

    A simple, rapid, solventless method for the determination of trihalomethanes (THMs) (chloroform, bromodichloromethane, dibromochloromethane and bromoform) in water samples is presented. The analytes are extracted from the headspace of the aqueous matrix into a 2 microL drop of the ionic liquid 1-octyl-3-methyl-imidazolium hexafluorophosphate working at 30 degrees C for 30 min. The separation and detection of the target compounds is accomplished by gas chromatography/mass spectrometry owing to the use of an interface that efficiently transfers the analytes extracted in the ionic liquid drop to the gas chromatograph while preventing the ionic liquid from entering the column. The detection limits obtained are below the values compelled by the legislation, ranging from 0.5 microg L(-1) for chloroform and bromodichloromethane to 0.9 microg L(-1) for dibromochloromethane. The use of ionic liquid in the extraction procedure avoids the use of organic solvents and leads to relative standard deviations that range from 3.1% to 4.8%.

  2. Evaluation of serpentine ore as a nuclear shielding material using gas chromatographic techniques

    International Nuclear Information System (INIS)

    Singh, B.N.; Unnikrishnan, E.K.; Kumar, Sangita D.

    2007-01-01

    Serpentine ore mixed with cement has been recognized as a candidate shielding material for use in nuclear reactors because of its many desirable properties. Therefore the assessment of serpentine ore for release of volatile gases during exposure to elevated temperatures, irradiation and changes in chemical composition, is essential. The present paper deals with the studies on the serpentine ores using gas chromatography and combustion gas chromatographic techniques. (author)

  3. Gas chromatographic measurement in water-steam circuits

    International Nuclear Information System (INIS)

    Zschetke, J.; Nieder, R.

    1984-01-01

    A gas chromatographic technique for measurements in water-steam circuits, which has been well known for many years, has been improved by design modifications. A new type of equipment developed for special measuring tasks on nuclear engineering plant also has a general application. To date measurements have been carried out on the ''Otto Hahn'' nuclear powered ship, on the KNK and AVR experimental nuclear power plants at Karlsruhe and Juelich respectively and on experimental boiler circuits. The measurements at the power plants were carried out under different operating conditions. In addition measurements during the alkali operating mode and during combined cycle operation were carried out on the AVR reactor. It has been possible to draw new conclusion from the many measurements undertaken. (orig.) [de

  4. Gas-liquid chromatographic determination of resmethrin in corn, cornmeal, flour, and wheat.

    Science.gov (United States)

    Simonaitis, R A; Cail, R S

    1975-09-01

    A gas-liquid chromatographic (GLC) method was developed for the determination of residues of resmethrin ((5-benzyl-3-furyl)methyl cis-trans-(+/-)-2,2-dimethyl-3-(2-methylpropenyl)-cyclopropanecarboxylate) in corn, cornmeal, flour, and wheat. The commodity, fortified with resmethrin, was extracted by tumbling with pentane and transferred to acetonitrile, the fat was partitioned off, and the sample was chromatographed with 3% ethyl acetate in pentane on Florisil containing 0.5% water. The resmethrin residue was determined by GLC with a flame ionization detector. The results were compared with known standards that had undergone the same cleanup procedures. The method was sensitive to concentrations of resmethrin to 0.2 ppm, recoveries averaged 83%, and reproducibility was good.

  5. Implementation of a fully automated process purge-and-trap gas chromatograph at an environmental remediation site

    International Nuclear Information System (INIS)

    Blair, D.S.; Morrison, D.J.

    1997-01-01

    The AQUASCAN, a commercially available, fully automated purge-and-trap gas chromatograph from Sentex Systems Inc., was implemented and evaluated as an in-field, automated monitoring system of contaminated groundwater at an active DOE remediation site in Pinellas, FL. Though the AQUASCAN is designed as a stand alone process analytical unit, implementation at this site required additional hardware. The hardware included a sample dilution system and a method for delivering standard solution to the gas chromatograph for automated calibration. As a result of the evaluation the system was determined to be a reliable and accurate instrument. The AQUASCAN reported concentration values for methylene chloride, trichloroethylene, and toluene in the Pinellas ground water were within 20% of reference laboratory values

  6. Use of the Keele injector for sample introduction for gas chromatographic analysis of vinclozolin in lettuces.

    Science.gov (United States)

    Shim, J H; Lee, Y S; Kim, M R; Lee, C J; Kim, I S

    2003-10-10

    We examined a Keele injector for sample introduction for gas chromatographic analysis of vinclozolin treated in lettuces. Samples in milligram quantity were introduced into a glass tube in a Keele injector at a gas chromatograph injection port. The glass tube was then crushed to allow the sample to carry onto a capillary column in a normal manner. The standard calibration curve for quantitative detection of vinclozolin was obtained by determining vinclozolin spiked in samples at variable concentrations. The calibration curve showed a linear response to vinclozolin ranging from 0.05 to 1.0 microg/g, giving a slope value of 174.8, the y-intercept value of -2.8146 and the mean r2-value of 0.9994. Limit of quantification for vinclozolin was 0.05 microg/g by this method, comparable to 0.01 microg/g by a normal injector. When samples treated previously with vinclozolin were determined by the Keele injector, vinclozolin was found to be about 30% lower as compared to a normal method, suggesting about 70% recovery of the spiked vinclozolin by the Keele injector. From these results, the Keele injector was suggested to be potential for sample introduction in gas chromatographic analysis of vinclozolin in lettuce samples.

  7. Rapid determination of methanol in black liquors by full evaporation headspace gas chromatography.

    Science.gov (United States)

    Li, Hailong; Zhan, Huaiyu; Fu, Shiyu; Liu, Mengru; Chai, Xin-Sheng

    2007-12-14

    This paper reported a full evaporation headspace gas chromatographic (GC) technique for determination of methanol content in black liquors (pulping spent liquor). In this method, a very small volume (10-20 microL) of liquor sample is introduced into a headspace sample vial (20 mL) and heated up to a temperature of 105 degrees C. A near-complete mass transfer of methanol from the liquid phase to vapor phase (headspace), i.e., a full evaporation, can be achieved within 3 min. The methanol in the headspace of the vial is then measured by GC. The present method is simple, rapid and accurate.

  8. Simultaneous derivatisation and preconcentration of parabens in food and other matrices by isobutyl chloroformate and dispersive liquid-liquid microextraction followed by gas chromatographic analysis.

    Science.gov (United States)

    Jain, Rajeev; Mudiam, Mohana Krishna Reddy; Chauhan, Abhishek; Ch, Ratnasekhar; Murthy, R C; Khan, Haider A

    2013-11-01

    A simple, rapid and economical method has been proposed for the quantitative determination of parabens (methyl, ethyl, propyl and butyl paraben) in different samples (food, cosmetics and water) based on isobutyl chloroformate (IBCF) derivatisation and preconcentration using dispersive liquid-liquid microextraction in single step. Under optimum conditions, solid samples were extracted with ethanol (disperser solvent) and 200 μL of this extract along with 50 μL of chloroform (extraction solvent) and 10 μL of IBCF was rapidly injected into 2 mL of ultra-pure water containing 150 μL of pyridine to induce formation of a cloudy state. After centrifugation, 1 μL of the sedimented phase was analysed using gas chromatograph-flame ionisation detector (GC-FID) and the peaks were confirmed using gas chromatograph-positive chemical ionisation-mass spectrometer (GC-PCI-MS). Method was found to be linear over the range of 0.1-10 μg mL(-1) with square of correlation coefficient (R(2)) in the range of 0.9913-0.9992. Limit of detection (LOD) and limit of quantification (LOQ) were found to be 0.029-0.102 μg mL(-1) and 0.095-0.336 μg mL(-1) with a signal to noise ratio of 3:1 and 10:1, respectively. Copyright © 2013 Elsevier Ltd. All rights reserved.

  9. Gas chromatographic determination of Di-n-butyl phosphate in radioactive lean organic solvent of FBTR carbide fuel reprocessing

    International Nuclear Information System (INIS)

    Velavendan, P.; Ganesh, S.; Pandey, N.K.; Kamachi Mudali, U.; Natarajan, R.

    2011-01-01

    In the present work Di-n- butyl phosphate (DBP) a degraded product of Tri-n-butyl phosphate (TBP) formed by acid hydrolysis and radiolysis in the PUREX process was analyzed. Lean organic streams of different fuel burn-up FBTR carbide fuel reprocessing solution was determined by standard Gas Chromatographic technique. The method involves the conversion of non-volatile Di-n-butyl phosphate into volatile and stable derivatives by the action of diazomethane and then determined by Gas Chromatograph (GC). A calibration graph was made for DBP concentration range of 200-2000 ppm with correlation coefficient of 0.99587 and RSD 1.2 %. (author)

  10. Gas-chromatographic quantitative determination of argon in air samples, by elimination of oxigen

    International Nuclear Information System (INIS)

    Sofronie, E.

    1982-08-01

    A method of gas-chromatographic quantitative determination of argon in air samples, by elimination of oxygen, is presented. Experiments were carried out in a static system. Conditions for the application of the method in dynamic systems are specified. Sensibility of the method: 5 10 -4 cm 3 Ar per cm 3 of air. (author)

  11. Chromatographic efficiency of polar capillary columns applied for the analysis of fatty acid methyl esters by gas chromatography.

    Science.gov (United States)

    Waktola, Habtewold D; Mjøs, Svein A

    2018-04-01

    The chromatographic efficiency that could be achieved in temperature-programmed gas chromatography was compared for four capillary columns that are typically applied for analysis of fatty acid methyl esters (FAME). Three different carrier gases, hydrogen, helium and nitrogen, were applied. For each experiment, the carrier gas velocities and the temperature rates were varied with a full 9 × 3 design, with nine levels on the carrier gas velocity and temperature rates of 1, 2 or 3°C/min. Response surface methodology was used to create models of chromatographic efficiency as a function of temperature rate and carrier gas velocity. The chromatographic efficiency was defined as the inverse of peak widths measured in retention index units. The final results were standardized so that the efficiencies that could be achieved within a certain time frame, defined by the retention time of the last compound in the chromatogram, could be compared. The results show that there were clear differences in the efficiencies that could be achieved with the different columns and that the efficiency decreased with increasing polarity of the stationary phase. The differences can be explained by higher resistance to mass transfer in the stationary phase in the most polar columns. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Gas chromatographic method fr determination of carbon in metallic uranium

    International Nuclear Information System (INIS)

    Nikol'skij, V.A.; Markov, V.K.; Evseeva, T.I.; Cherstvenkova, E.P.

    1983-01-01

    Gas chromatographic device to determine carbon in metal uranium is developed. Burnout unite, permitting to load in the burnout tube simultaneously quite a few (up to 20) weight amounts of materials to be burned is a characteristic feature of the device. As a result amendments for control experiment and determination limit are decreased. The time of a single determination is also reduced. Conditions of carbon burn out from metal uranium are studied and temperature and time of complete extraction of carbon in the form of dioxide from weight amount into gaseous phase are established

  13. Rapid and simple clean-up and derivatizaton procedure for the gas chromatographic determination of acidic drugs in plasma

    NARCIS (Netherlands)

    Roseboom, H.; Hulshoff, A.

    1979-01-01

    A rapid and simple clean-up and derivatization procedure that can be generally applied to the gas chromatographie (GC) determination of acidic drugs of various chemical and therapeutic classes is described. The drugs are extracted from acidified plasma with chloroform containing 5% of isopropanol,

  14. Chemometric strategy for automatic chromatographic peak detection and background drift correction in chromatographic data.

    Science.gov (United States)

    Yu, Yong-Jie; Xia, Qiao-Ling; Wang, Sheng; Wang, Bing; Xie, Fu-Wei; Zhang, Xiao-Bing; Ma, Yun-Ming; Wu, Hai-Long

    2014-09-12

    Peak detection and background drift correction (BDC) are the key stages in using chemometric methods to analyze chromatographic fingerprints of complex samples. This study developed a novel chemometric strategy for simultaneous automatic chromatographic peak detection and BDC. A robust statistical method was used for intelligent estimation of instrumental noise level coupled with first-order derivative of chromatographic signal to automatically extract chromatographic peaks in the data. A local curve-fitting strategy was then employed for BDC. Simulated and real liquid chromatographic data were designed with various kinds of background drift and degree of overlapped chromatographic peaks to verify the performance of the proposed strategy. The underlying chromatographic peaks can be automatically detected and reasonably integrated by this strategy. Meanwhile, chromatograms with BDC can be precisely obtained. The proposed method was used to analyze a complex gas chromatography dataset that monitored quality changes in plant extracts during storage procedure. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. A rapid and simple procedure for monitoring valproic acid by gas chromatography

    Directory of Open Access Journals (Sweden)

    Mohamed Said Mostafa

    2018-02-01

    Full Text Available Valproic acid (VPA, a widely used antiepileptic drug, has a narrow therapeutic range of 50-100 μg/mL and shows large individual variability. It is very important to monitor the trough VPA concentration using a reliable method. The aim of this study was to develop and validate a rapid gas chromatographic (GC technique for VPA quantification in human plasma and to compare it with the traditional immunoassay method. VPA extraction from human serum was efficient by dichloromethane and hydrochloric acid using octanoic acid as an internal standard. GC analysis was performed using a gas-chromatograph equipped with a flame ionization detector (GC/FID. VPA detection and quantification were accomplished isothermally at 135°C on a Gs-BP 100% dimethylpolysiloxane capillary column (10 m×0.53 mm ID, 2.65 μm film thickness, Supelco, Bellefonte, PA. Injection port and detector temperature were 280°C. Retention times of VPA and internal standard were 1.83 min and 2.33 min, respectively. The calibration curve was linear over the concentration range of 5-320 μg/mL, with a lower limit of detection of 1.25 μg/mL. The internal and inter-day precision was less than 5.3% and 6.1%, respectively, and the accuracy was below 2.8%. VPA recovery was 94.6%. A quick and accurate method for VPA determination in human plasma was developed and validated. It resulted sufficiently selective and sensitive.

  16. Gas chromatographic sensing on an optical fiber by mode-filtered light detection.

    Science.gov (United States)

    Bruckner, C A; Synovec, R E

    1996-06-01

    A chemical sensor for gas phase measurements is reported which combines the principles of chemical separation and fiber optic detection. The analyzer incorporates an annular column Chromatographic sensor, constructed by inserting a polymer-clad optical fiber into a silica capillary. Light from a helium-neon laser is launched down the fiber, producing a steady intensity distribution within the fiber, but a low background of scattered light. When sample vapor is introduced to the sensor, and an analyte-rich volume interacts with the polymer cladding, Chromatographic retention is observed simultaneously with a change in the local refractive index of the cladding. An increase in cladding refractive index (RI) causes light to be coupled out of the fiber, with detection at a right-angle to the annular column length to provide optimum S/N ratio. This detection mechanism is called mode-filtered light detection. We report a gas Chromatographic separation on a 3.1 m annular column (320 microm i.d. silica tube, 228 microm o.d. fiber with a 12 microm fluorinated silicone clad) of methane, benzene, butanone and chlorobenzene in 6 min. The annular column length was reduced to 22 cm to function as a sensor, with selected organic vapors exhibiting unique retention times and detection selectivity. The detection selectivity is determined by the analyte RI and the partition coefficient into the cladding. The calculated limit of detection (LOD) for benzene vapor is 0.03% by volume in nitrogen, and several chlorinated species had LOD values less than 1%. For binary mixtures of organic vapors, the detected response appears to be the linear combination of the two organic standards, suggesting that the annular column may be useful as a general approach for designing chemical sensors that incorporate separation and optical detection principles simultaneously.

  17. New method for evaluating irreversible adsorption and stationary phase bleed in gas chromatographic capillary columns.

    Science.gov (United States)

    Wright, Bob W; Wright, Cherylyn W

    2012-10-26

    A novel method is described for the evaluation of irreversible adsorption and column bleed in gas chromatographic (GC) columns using a tandem GC approach. This work specifically determined the degree of irreversible adsorption behavior of specific sulfur and phosphorous containing test probe compounds at levels ranging from approximately 50 picograms (pg) to 1 nanogram (ng) on selected gas chromatographic columns. This method does not replace existing evaluation methods that characterize reversible adsorption but provides an additional tool. The test compounds were selected due to their ease of adsorption and their importance in the specific trace analytical detection methodology being developed. Replicate chromatographic columns with 5% phenylmethylpolysiloxane (PMS), polyethylene glycol (wax), trifluoropropylpolysiloxane (TFP), or 78% cyanopropylpolysiloxane stationary phases from a variety of vendors were evaluated. As expected, the results demonstrate that the different chromatographic phases exhibit differing degrees of irreversible adsorption behavior. The results also indicate that all manufacturers do not produce equally inert columns nor are columns from a given manufacturer identical. The wax-coated columns for the test probes used were more inert as a group than 5% PMS coated columns, and they were more reproducibly manufactured. Both TFP and 78% cyanopropylpolysiloxane columns displayed superior inertness to the test compounds compared to either 5% PMS- or wax-coated columns. Irreversible adsorption behavior was characterized for a limited range of stationary phase film thicknesses. In addition, the method was shown effective for characterizing column bleed and methods to remove bleed components. This method is useful in screening columns for demanding applications and to obtain diagnostic information related to improved preparation methods. Copyright © 2012 Elsevier B.V. All rights reserved.

  18. Gas chromatographic/mass spectrometric determination of carbon isotope composition in unpurified samples: methamphetamine example.

    Science.gov (United States)

    Low, I A; Liu, R H; Legendre, M G; Piotrowski, E G; Furner, R L

    1986-10-01

    A gas chromatograph/quadrupole mass spectrometer system, operated in electron impact/selected ion monitoring mode, is used to determine the intensity ratio of the m/z 59 and the m/z 58 ions of the [C3H8N]+ fragment derived from methamphetamine samples synthesized with varying amounts of 13C-labeled methylamine. Crude products are introduced into the gas chromatograph without prior cleanup. The ratios measured were in excellent agreement with those calculated. A change in 0.25% use of 13C-methylamine is sufficient for product differentiation. The feasibility of using isotope labeling and subsequent mass spectrometric isotope ratio measurement as the basis of a compound tracing mechanism is discussed. Specifically, if methamphetamine samples manufactured from legal sources are asked to incorporate distinct 13C compositions, their sources can be traced when samples are diverted into illegal channels. Samples derived from illicit preparations can also be traced if the manufacturers of a precursor (methylamine in this case) incorporate distinct 13C compositions in their products.

  19. Detection system for a gas chromatograph. [. cap alpha. -methylnaphthalene,. beta. -methylnapthalene

    Science.gov (United States)

    Hayes, J.M.; Small, G.J.

    1982-04-26

    A method and apparatus are described for the quantitative analysis of vaporizable compounds, and in particular of polycyclic aromatic hydrocarbons which may be induced to fluoresce. The sample to be analyzed is injected into a gas chromatography column and is eluted through a narrow orifice into a vacuum chamber. The free expansion of the eluted sample into the vacuum chamber creates a supersonic molecular beam in which the sample molecules are cooled to the extent that the excited vibrational and rotational levels are substantially depopulated. The cooled molecules, when induced to fluoresce by laser excitation, give greatly simplified spectra suitable for analytical purposes. The laser induced fluorimetry provides great selectivity, and the gas chromatograph provides quantitative transfer of the sample to the molecular beam. 3 figures, 2 tables.

  20. Rapid on-site sensing aflatoxin B1 in food and feed via a chromatographic time-resolved fluoroimmunoassay.

    Directory of Open Access Journals (Sweden)

    Zhaowei Zhang

    Full Text Available Aflatoxin B1 poses grave threats to food and feed safety due to its strong carcinogenesis and toxicity, thus requiring ultrasensitive rapid on-site determination. Herein, a portable immunosensor based on chromatographic time-resolved fluoroimmunoassay was developed for sensitive and on-site determination of aflatoxin B1 in food and feed samples. Chromatographic time-resolved fluoroimmunoassay offered a magnified positive signal and low signal-to-noise ratio in time-resolved mode due to the absence of noise interference caused by excitation light sources. Compared with the immunosensing performance in previous studies, this platform demonstrated a wider dynamic range of 0.2-60 μg/kg, lower limit of detection from 0.06 to 0.12 µg/kg, and considerable recovery from 80.5% to 116.7% for different food and feed sample matrices. It was found to be little cross-reactivity with other aflatoxins (B2, G1, G2, and M1. In the case of determination of aflatoxin B1 in peanuts, corn, soy sauce, vegetable oil, and mouse feed, excellent agreement was found when compared with aflatoxin B1 determination via the conversational high-performance liquid chromatography method. The chromatographic time-resolved fluoroimmunoassay affords a powerful alternative for rapid on-site determination of aflatoxin B1 and holds a promise for food safety in consideration of practical food safety and environmental monitoring.

  1. Rapid on-site sensing aflatoxin B1 in food and feed via a chromatographic time-resolved fluoroimmunoassay.

    Science.gov (United States)

    Zhang, Zhaowei; Tang, Xiaoqian; Wang, Du; Zhang, Qi; Li, Peiwu; Ding, Xiaoxia

    2015-01-01

    Aflatoxin B1 poses grave threats to food and feed safety due to its strong carcinogenesis and toxicity, thus requiring ultrasensitive rapid on-site determination. Herein, a portable immunosensor based on chromatographic time-resolved fluoroimmunoassay was developed for sensitive and on-site determination of aflatoxin B1 in food and feed samples. Chromatographic time-resolved fluoroimmunoassay offered a magnified positive signal and low signal-to-noise ratio in time-resolved mode due to the absence of noise interference caused by excitation light sources. Compared with the immunosensing performance in previous studies, this platform demonstrated a wider dynamic range of 0.2-60 μg/kg, lower limit of detection from 0.06 to 0.12 µg/kg, and considerable recovery from 80.5% to 116.7% for different food and feed sample matrices. It was found to be little cross-reactivity with other aflatoxins (B2, G1, G2, and M1). In the case of determination of aflatoxin B1 in peanuts, corn, soy sauce, vegetable oil, and mouse feed, excellent agreement was found when compared with aflatoxin B1 determination via the conversational high-performance liquid chromatography method. The chromatographic time-resolved fluoroimmunoassay affords a powerful alternative for rapid on-site determination of aflatoxin B1 and holds a promise for food safety in consideration of practical food safety and environmental monitoring.

  2. Gas chromatographic analysis of volatiles in fluid and gas inclusions

    Science.gov (United States)

    Andrawes, F.; Holzer, G.; Roedder, E.; Gibson, E.K.; Oro, John

    1984-01-01

    Most geological samples and some synthetic materials contain fluid inclusions. These inclusions preserve for us tiny samples of the liquid and/or the gas phase that was present during formation, although in some cases they may have undergone significant changes from the original material. Studies of the current composition of the inclusions provide data on both the original composition and the change since trapping.These inclusions are seldom larger than 1 millimeter in diameter. The composition varies from a single major compound (e.g., water) in a single phase to a very complex mixture in one or more phases. The concentration of some of the compounds present may be at trace levels.We present here some analyses of inclusions in a variety of geological samples, including diamonds. We used a sample crusher and a gas chromatography—mass spectrometry (GC—MS) system to analyze for organic and inorganic volatiles present as major to trace constituents in inclusions. The crusher is a hardened stainless-steel piston cylinder apparatus with tungsten carbide crusing surfaces, and is operated in a pure helium atmosphere at a controlled temperature.Samples ranging from 1 mg to 1 g were crushed and the released volatiles were analyzed using multi-chromatographic columns and detectors, including the sensitive helium ionization detector. Identification of the GC peaks was carried out by GC—MS. This combination of procedures has been shown to provide geochemically useful information on the process involved in the history of the samples analyzed.

  3. Rapid determination of cholesterol in milk and milk products by direct saponification and capillary gas chromatography.

    Science.gov (United States)

    Fletouris, D J; Botsoglou, N A; Psomas, I E; Mantis, A I

    1998-11-01

    A simple method is described for the determination of cholesterol in milk and milk products. Samples (0.2 g) are saponified in capped tubes with 0.5 M methanolic KOH solution by heating for 15 min at 80 degrees C. Water is added to the mixtures, and the unsaponifiable fractions are extracted with hexane to be further analyzed by capillary gas chromatography. Because of the rapid sample preparation and gas chromatographic procedures, a single sample can be analyzed in 30 min. Overall recovery was 98.6%, and the linearity was excellent for the fortification range examined. Precision data that were based on the variation within and between days suggested an overall relative standard deviation value of 1.4%. The method has been successfully applied to quantitate cholesterol in a variety of milk products.

  4. Chromatographic separations of stereoisomers

    Energy Technology Data Exchange (ETDEWEB)

    Souter, R.W.

    1985-01-01

    This text covers both diastereomers and enantiomers; describes techniques for GC, HPLC, and other chromatographic methods; and tabulates results of various applications by both techniques and compound class. It provides current knowledge about separation mechanisms and interactions of asymmetric molecules, as well as experimental and commercial materials such as columns, instruments, and derivatization reagents. The contents also include stereoisomer separations by gas chromatography. Stereoisomer separations by high-performance liquid chromatography. Stereoisomer separations by other chromatographic techniques.

  5. A simple and rapid gas chromatographic method for the determination of dissolved deuterium and nitrogen in heavy water coolant of a nuclear reactor

    International Nuclear Information System (INIS)

    Nair, B.K.S.

    1976-01-01

    A known volume of a heavy water sample is equilibrated with a known volume of pure helium gas at atmospheric pressure in a sample tube. The dissolved gases evolve into the helium and distribute themselves between the gaseous and liquid phases according to their equilibrium partial pressures. These partial pressures of the gases in the equilibrium gas mixture are determined by analysing it gas-chromatographically. From these analytical data and the absorption coefficients of deuterium and nitrogen, their original concentrations in heavy water are calculated. Corrections for the increase in the total pressure of the gaseous phase owing to evolved gases are calculated and found to be negligible. Air contamination during sampling and analysis can be detected by the presence of the oxygen peak in the chromatogram and corrected for. The calculation is facilitated by programming it on an electronic calculator. The method is much simpler and faster than the vacuum method usually applied for this analysis. One determination can be completed in about an hour. The average deviation and standard deviation have been estimated at 0.19 ml/litre heavy water and 0.25 ml/litre heavy water respectively in deuterium, and 0.36 and 0.68 ml/litre in nitrogen. (author)

  6. A mobile automatic gas chromatograph system to measure CO2, CH4 and N2O fluxes from soil in the field

    International Nuclear Information System (INIS)

    Silvola, J.; Martikainen, P.; Nykaenen, H.

    1992-01-01

    A caravan has been converted into mobile laboratory for measuring fluxes of CO 2 , CH 4 and N 2 O from the soil in the field. The caravan was equipped with a gas chromatograph fitted with TC-, FI- and EC-detectors, and a PC controlled data logger. The gas collecting chambers can be used up to 50 m from the caravan. The closing and opening of the chambers, as well as the flows of sample gases from chambers to the gas chromatograph. is pneumatically regulated. Simultaneous recordings of temperature, light intensity and the depth of water table are made. The system has been used for two months in 1992, and some preliminary results are presented

  7. Rapid planar chromatographic analysis of 25 water-soluble dyes used as food additives.

    Science.gov (United States)

    Morlock, Gertrud E; Oellig, Claudia

    2009-01-01

    A rapid planar chromatographic method for identification and quantification of 25 water-soluble dyes in food was developed. In a horizontal developing chamber, the chromatographic separation on silica gel 60F254 high-performance thin-layer chromatography plates took 12 min for 40 runs in parallel, using 8 mL ethyl acetate-methanol-water-acetic acid (65 + 23 + 11 + 1, v/v/v/v) mobile phase up to a migration distance of 50 mm. However, the total analysis time, inclusive of application and evaluation, took 60 min for 40 runs. Thus, the overall time/run can be calculated as 1.5 min with a solvent consumption of 200 microL. A sample throughput of 1000 runs/8 h day can be reached by switching between the working stations (application, development, and evaluation) in a 20 min interval, which triples the analysis throughput. Densitometry was performed by absorption measurement using the multiwavelength scan mode in the UV and visible ranges. Repeatabilities [relative standard deviation (RSD), 4 determinations] at the first or second calibration level showed precisions of mostly or = 0.9987) and RSD values ( or = 0.9996). If necessary for confirmation, online mass spectra were recorded within a minute.

  8. Gas chromatographic simulated distillation-mass spectrometry for the determination of the boiling point distributions of crude oils

    Science.gov (United States)

    Roussis; Fitzgerald

    2000-04-01

    The coupling of gas chromatographic simulated distillation with mass spectrometry for the determination of the distillation profiles of crude oils is reported. The method provides the boiling point distributions of both weight and volume percent amounts. The weight percent distribution is obtained from the measured total ion current signal. The total ion current signal is converted to weight percent amount by calibration with a reference crude oil of a known distillation profile. Knowledge of the chemical composition of the crude oil across the boiling range permits the determination of the volume percent distribution. The long-term repeatability is equivalent to or better than the short-term repeatability of the currently available American Society for Testing and Materials (ASTM) gas chromatographic method for simulated distillation. Results obtained by the mass spectrometric method are in very good agreement with results obtained by conventional methods of physical distillation. The compositional information supplied by the method can be used to extensively characterize crude oils.

  9. Abnormal tyrosine and phenylalanine metabolism in patients with tyrosyluria and phenylketonuria; gas-liquid chromatographic analysis of urinary metabolites

    NARCIS (Netherlands)

    Wadman, S.K.; Heiden, C. van der; Ketting, D.; Sprang, F.J. van

    Gas-liquid chromatographic methods have been developed for the analysis of: urinary phenylalanine metabolites (I) in patients with phenylketonuria, tyrosine metabolites (II) in patients with a disturbed tyrosine metabolism at the level of p-hydroxyphenylpyruvate hydroxylase, and homogentisic acid in

  10. The adaptive internet application for interpretation of the transformer oil gas chromatographic analysis results

    Directory of Open Access Journals (Sweden)

    Polužanski Vladimir

    2015-01-01

    Full Text Available This paper describes an adaptive Internet application for the interpretation of the transformer oil gas chromatographic analysis results. The first version of the application is developed by following an evolutionary software development concept. The most important software development risks and the appropriate solutions are described. An open-source web framework named Bootstrap is used for an application implementation. The application is developed by using ASP.NET and MS SQL server.

  11. Multidimensional High-Resolution Gas Chromatographic Investigations of Hydrocarbon Fuels and Various Turbine Engine Fuel Precursors.

    Science.gov (United States)

    1985-08-01

    time were spurious transits observed during the recording of the chromatographic output data. *Packaged gas purification filters supplied by Alltech ... Alltech ) that were needed for these unusual installations. When the column diameters were small and of comparable size, the assembly attach- ments at...into an MDGC system has definite advantages as separations can be made faster and with greater detectability. However, specific precautions must be

  12. Chromatographic monitoring procedures in laboratory practice

    Energy Technology Data Exchange (ETDEWEB)

    Kaplina, E G; Belova, O I; Lasunina, N A

    1976-01-01

    The Moscow Coke and Chemical Works consist of three plants in combination, viz., the coking plant, the synthetic ammonia plant using coke-oven-gas hydrogen and the oxygen plant. The plant requirements include daily analyses not only of the coke-oven gas but also of a rich gas and an ethylene fraction. The analyses are carried out in VTI-2 apparatus. The analytical data are used to calculate the calorific values and densities of the gases. The time requirements are very considerable and the laboratory has long been engaged in developing and introducing chromatographic procedures for the major constituents of coke-oven gas, rich gas and ethylene fraction. The procedure developed for the coke-oven and rich gases uses two parallel columns, one packed with molecular sieves and the other with grade KSM silica gel. Hydrogen was determined with argon as the carrier gas, and all other constituents with helium. The procedure was time-consuming and complicated. An attempt was made to separate the gases in an LKhM-7a chromatograph with a programme-controlled 50 to 250/sup 0/C heating cycle, but the procedure still had a number of serious defects and could not be recommended for regular quality control. The final variant involved two parallel columns and a procedure based on that in GOST 14920 (''Dry gas. Proximate analysis''). The chromatograph was a type KhL-69 with a 6-way cock in the gas line so that each of the columns could be brought on stream in succession. The analytical column packings were zeolite (in a 2 m column) and diatomaceous brick with 25% n-hexadecane (in a 6 m column).

  13. Radioimmunoassay of methaqualone in human urine compared with chromatographic methods

    International Nuclear Information System (INIS)

    Mule, S.J.; Kogan, M.; Jukofsky, D.

    1978-01-01

    The 125 I-radioimmunoassay for methaqualone in human urine was evaluated by a comparison with newly modified gas-liquid chromatographic and thin-layer chromatographic methods. The statistically significant sensitivity value for the radioimmunoassay was at 2 μg of methaqualone per liter of urine. The coefficient of variation was 2.88 -+ 0.16% intraassay. There was cross-reactivity only with metabolites of methaqualone, 4'-hydroxymethaqualone being twice as sensitively measured as methaqualone. There was complete agreement between results by radioimmunoassay and by gas-liquid chromatography in 96.7% of the samples analyzed. Only 1.2% of the radioimmunoassay values were false positives, and 2.1% false negatives (phi = 0.8917, P < 0.001). Comparisons between the thin-layer chromatographic data and the gas--liquid chromatographic or radioimmunoassay data showed less agreement because of the 50- to 200-fold higher sensitivity of the latter techniques. Gas--liquid chromatography therefore appears to represent the best reference method for the evaluation of the radioimmunoassay, which appears to be a very sensitive and reliable technique for detecting methaqualone and its metabolites in human urine

  14. Proposal for data acquisition system of gas chromatograph and natural gas transfer custody via web; Proposta para um sistema de aquisicao de dados de cromatografia e medicao fiscal de gas natural via web

    Energy Technology Data Exchange (ETDEWEB)

    Santana, Jose Paulo C.; Guimaraes, Marcelo F.; Zeitoune, Rafael J. [PETROBRAS, Rio de Janeiro, RJ (Brazil)

    2005-07-01

    In this paper, is presented a proposal of a Chromatograph and Transfer Custody Measurement Data Acquisition System through Web, complementary to the SCADA System, responsible for control and monitoring PETROBRAS Gas Pipelines, intended to comply with the requirements of the Gerencias de Qualidade e Medicao (MQD) and Planejamento Integrado da Logistica (PCL) from PETROBRAS Gas e Energia, regarding the evaluation of the quality of the natural gas that is being commercialized, as well as its billing. (author)

  15. A purge-and-trap capillary column gas chromatographic method for the measurement of halocarbons in water and air

    Energy Technology Data Exchange (ETDEWEB)

    Happell, J.D.; Wallace, D.W.R.; Wills, K.D.; Wilke, R.J.; Neill, C.C.

    1996-06-01

    This report describes an automated, accurate, precise and sensitive capillary column purge- and -trap method capable of quantifying CFC-12, CFC-11, CFC-113, CH{sub 3}CCL{sub 3}, and CCL{sub 4} during a single chromatographic analysis in either water or gas phase samples.

  16. Diagnosis of rinderpest in Tanzania by a rapid chromatographic strip-test.

    Science.gov (United States)

    Wambura, P N; Moshy, D W; Mbise, A N; Mollel, G O; Taylor, W P; Anderson, J; Bruning, A

    2000-06-01

    A simple chromatographic strip-test based on Clearview technology, is under development as a pen-side test for the detection of rinderpest antigen in eye swabs taken from cattle in the field. An outbreak of rinderpest occurred in the northern zone of Tanzania from late February to June 1997. The affected cattle exhibited very mild clinical signs, which made clinical diagnosis difficult. One hundred and seven eye swabs were collected from cattle suspected of infection with rinderpest. These were tested in the field using a prototype of the pen-side test and 13 (12.15%) of the samples were found to be positive for the presence of rinderpest antigen. These were confirmed by ICE. The positive cases were predominantly found in the Ngorongoro district. This demonstrates the usefulness of such a simple, rapid pen-side diagnostic assay, particularly when clinically 'mild' strains of rinderpest are present.

  17. Thermal soil desorption for total petroleum hydrocarbon testing on gas chromatographs

    International Nuclear Information System (INIS)

    Mott, J.

    1995-01-01

    Testing for total petroleum hydrocarbons (TPH) is one of the most common analytical tests today. A recent development in chromatography incorporates Thermal Soil Desorption technology to enable analyses of unprepared soil samples for volatiles such as BTEX components and semi-volatiles such as diesel, PCBs, PAHs and pesticides in the same chromatogram, while in the field. A gas chromatograph is the preferred method for determining TPH because the column in a GC separates the individual hydrocarbons compounds such as benzene and toluene from each other and measures each individually. A GC analysis will determine not only the total amount of hydrocarbon, but also whether it is gasoline, diesel or another compound. TPH analysis with a GC is typically conducted with a Flame Ionization Detector (FID). Extensive field and laboratory testing has shown that incorporation of a Thermal Soil Desorber offers many benefits over traditional analytical testing methods such as Headspace, Solvent Extraction, and Purge and Trap. This paper presents the process of implementing Thermal Soil Desorption in gas chromatography, including procedures for, and advantages of faster testing and analysis times, concurrent volatile and semi-volatile analysis, minimized sample manipulation, single gas (H 2 ) operation, and detection to the part-per billion levels

  18. A low-power pressure-and temperature-programmed separation system for a micro gas chromatograph.

    Energy Technology Data Exchange (ETDEWEB)

    Sacks, Richard D. (University of Michigan, Ann Arbor, MI); Robinson, Alex Lockwood (Advanced Sensor Technologies, Albuquerque, NM); Lambertus, Gordon R. (University of Michigan, Ann Arbor, MI); Potkay, Joseph A. (University of Michigan, Ann Arbor, MI); Wise, Kensall D. (University of Michigan, Ann Arbor, MI)

    2006-10-01

    This thesis presents the theory, design, fabrication and testing of the microvalves and columns necessary in a pressure- and temperature-programmed micro gas chromatograph ({micro}GC). Two microcolumn designs are investigated: a bonded Si-glass column having a rectangular cross section and a vapor-deposited silicon oxynitride (Sion) column having a roughly circular cross section. Both microcolumns contain integrated heaters and sensors for rapid, controlled heating. The 3.2 cm x 3.2 cm, 3 m-long silicon-glass column, coated with a non-polar polydimethylsiloxane (PDMS) stationary phase, separates 30 volatile organic compounds (VOCs) in less than 6 min. This is the most efficient micromachined column reported to date, producing greater than 4000 plates/m. The 2.7 mm x 1.4 mm Sion column eliminates the glass sealing plate and silicon substrate using deposited dielectrics and is the lowest power and fastest GC column reported to date; it requires only 11 mW to raise the column temperature by 100 C and has a response time of 11s and natural temperature ramp rate of 580 C/min. A 1 m-long PDMS-coated Sion microcolumn separates 10 VOCs in 52s. A system-based design approach was used for both columns.

  19. Application of Gas Chromatographic analysis to RPC detectors in the ATLAS experiment at CERN-LHC

    CERN Document Server

    De Asmundis, R

    2007-01-01

    Starting from 2007 a large number (1200) Resistive Plate Chambers (RPC) detectors will be used as muon trigger detectors in the ATLAS Experiment at CERN-LHC accelerator. RPC are gaseous detector in which the quality and the stability of the gas mixture as well as the design of the gas supplying system, play a fundamental role in their functioning. RPC are foreseen to work more than ten years in the high radiation environment of ATLAS and the gas mixture acts really as a "lifeguard" for the detectors. For this reason a great attention has been devoted to the gas studies in order to optimize RPC performance, robustness and reliability in a high radiation environment. In this paper we describe the work done to decide how to supply and control in an optimal way the gas to the detectors, in order to ensure their best performance for a long time. The activity, based on Gas Chromatographic (GC) analysis, has been carried on a sample of final RPC working in radiation conditions much more intense than those foreseen f...

  20. An automated multidimensional preparative gas chromatographic system for isolation and enrichment of trace amounts of xenon from ambient air.

    Science.gov (United States)

    Larson, Tuula; Östman, Conny; Colmsjö, Anders

    2011-04-01

    The monitoring of radioactive xenon isotopes is one of the principal methods for the detection of nuclear explosions in order to identify clandestine nuclear testing. In this work, a miniaturized, multiple-oven, six-column, preparative gas chromatograph was constructed in order to isolate trace quantities of radioactive xenon isotopes from ambient air, utilizing nitrogen as the carrier gas. The multidimensional chromatograph comprised preparative stainless steel columns packed with molecular sieves, activated carbon, and synthetic carbon adsorbents (e.g., Anasorb®-747 and Carbosphere®). A combination of purification techniques--ambient adsorption, thermal desorption, back-flushing, thermal focusing, and heart cutting--was selectively optimized to produce a well-defined xenon peak that facilitated reproducible heart cutting and accurate quantification. The chromatographic purification of a sample requires approximately 4 h and provides complete separation of xenon from potentially interfering components (such as water vapor, methane, carbon dioxide, and radon) with recovery and accuracy close to 100%. The preparative enrichment process isolates and concentrates a highly purified xenon gas fraction that is suitable for subsequent ultra-low-level γ-, ß/γ-spectroscopic or high-resolution mass spectrometric measurement (e.g., to monitor the gaseous fission products of nuclear explosions at remote locations). The Xenon Processing Unit is a free-standing, relatively lightweight, and transportable system that can be interfaced to a variety of sampling and detection systems. It has a relatively inexpensive, rugged, and compact modular (19-inch rack) design that provides easy access to all parts for maintenance and has a low power requirement.

  1. Qualification of an Agilent Technologies 7890A gas chromatograph used in the biotechnology industry

    International Nuclear Information System (INIS)

    Alvarez Gonzalez, Alberto; Tambara Hernandez, Yanet; Alvarez Gil, Felix

    2014-01-01

    The drug manufacture is governed by strict international standards that guarantee reproducibility and consistency of results. The qualification of the instruments used in the productive processes, as well as in the characterization of products and their quality control are prerequisites to the validation of any analytical technique using them. One of the instrumental techniques used in the biotechnical industry is Gas Chromatography. A standard of pure caffeine was used for analysis in addition to a HP-5 30 m x 0,32 mm d.i. and 0,33 μm thick film column was used in a Gas Chromatograph coupled with a Flame Ionization Detector. For the testing of the different modules involved in the analysis (injector, column, oven and detector), an experimental design was made to estimate several parameters

  2. A single gas chromatograph for accurate atmospheric mixing ratio measurements of CO2, CH4, N2O, SF6 and CO

    NARCIS (Netherlands)

    van der Laan, S.; Neubert, R. E. M.; Meijer, H. A. J.; Simpson, W.R.

    2009-01-01

    We present an adapted gas chromatograph capable of measuring simultaneously and semi-continuously the atmospheric mixing ratios of the greenhouse gases CO2, CH4, N2O and SF6 and the trace gas CO with high precision and long-term stability. The novelty of our design is that all species are measured

  3. Gas Chromatographic Determination of Fatty Acids in Oils with Regard to the Assessment of Fire Hazard

    Science.gov (United States)

    Bartošová, Alica; Štefko, Tomáš

    2017-06-01

    The aim of the paper was to study and research the application of processing gas chromatographic method for the rapid and accurate determination of the composition of different types of oils, such as substances with the possibility of an adverse event spontaneous combustion or self-heating. Tendency to spontaneous combustion is chemically characterized mainly by the amount of unsaturated fatty acids, which have one or more double bonds in their molecule. Vegetable oils essentially consist of the following fatty acids: palmitic, stearic, oleic, linoleic, and linoleic. For the needs of assessment, the fire hazard must be known, in which the double bond is present, as well as their number in a molecule. As an analytical method, GCMS was used for determination of oils content. Three types of oil were used - rapeseed, sunflower, and coconut oil. Owing to the occurrence of linoleic acid C18:2 (49.8 wt.%) and oleic acid C18:1 (43.3 wt.%) with double bonds, sunflower oil is the most prone to self-heating. The coconut and rapeseed oils contain double bond FAME in lesser amount, and their propensity to self-heating is relatively low.

  4. Characterization of crude oils and petroleum products: (I Elution liquid chromatographic separation and gas chromatographic analysis of crude oils and petroleum products

    Directory of Open Access Journals (Sweden)

    E.O. Odebunmi

    2002-12-01

    Full Text Available Some physical and chemical properties of samples of light, medium and heavy Nigerian crude oils and petroleum products including gasoline, kerosene and engine oil have been measured and are reported in this paper. The crude oils and petroleum products have also been characterized by fractional distillation and elution liquid chromatography. The fractions obtained from elution liquid chromatography were analyzed using gas chromatography (GC. The GC fractions were identified by comparing the retention time of peaks in the unknown samples with those of components of calibration standard mixtures. The importance of the physico-chemical properties and the significance of the fractional distillation and chromatographic separation methods to industrial process operations have been discussed.

  5. In situ derivatization and hollow fiber membrane microextraction for gas chromatographic determination of haloacetic acids in water

    Energy Technology Data Exchange (ETDEWEB)

    Varanusupakul, Pakorn [Chromatography and Separation Research Unit, Department of Chemistry, Faculty of Science, Chulalongkorn University, Phayathai Road, Patumwan, Bangkok 10330 (Thailand)], E-mail: pakorn.v@chula.ac.th; Vora-adisak, Narongchai; Pulpoka, Bancha [Chromatography and Separation Research Unit, Department of Chemistry, Faculty of Science, Chulalongkorn University, Phayathai Road, Patumwan, Bangkok 10330 (Thailand)

    2007-08-15

    An alternative method for gas chromatographic determination of haloacetic acids (HAAs) in water using direct derivatization followed by hollow fiber membrane liquid-phase microextraction (HF-LPME) has been developed. The method has improved the sample preparation step according to the conventional US EPA Method 552.2 by combining the derivatization and the extraction into one step prior to determination by gas chromatography electron captured detector (GC-ECD). The HAAs were derivatized with acidic methanol into their methyl esters and simultaneously extracted with supported liquid hollow fiber membrane in headspace mode. The derivatization was attempted directly in water sample without sample evaporation. The HF-LPME was performed using 1-octanol as the extracting solvent at 55 deg. C for 60 min with 20% Na{sub 2}SO{sub 4}. The linear calibration curves were observed for the concentrations ranging from 1 to 300 {mu}g L{sup -1} with the correlation coefficients (R{sup 2}) being greater than 0.99. The method detection limits of most analytes were below 1 {mu}g L{sup -1} except DCAA and MCAA that were 2 and 18 {mu}g L{sup -1}, respectively. The recoveries from spiked concentration ranged from 97 to 109% with %R.S.D. less than 12%. The method was applied for determination of HAAs in drinking water and tap water samples. The method offers an easy one step high sample throughput sample preparation for gas chromatographic determination of haloacetic acids as well as other contaminants in water.

  6. In situ derivatization and hollow fiber membrane microextraction for gas chromatographic determination of haloacetic acids in water

    International Nuclear Information System (INIS)

    Varanusupakul, Pakorn; Vora-adisak, Narongchai; Pulpoka, Bancha

    2007-01-01

    An alternative method for gas chromatographic determination of haloacetic acids (HAAs) in water using direct derivatization followed by hollow fiber membrane liquid-phase microextraction (HF-LPME) has been developed. The method has improved the sample preparation step according to the conventional US EPA Method 552.2 by combining the derivatization and the extraction into one step prior to determination by gas chromatography electron captured detector (GC-ECD). The HAAs were derivatized with acidic methanol into their methyl esters and simultaneously extracted with supported liquid hollow fiber membrane in headspace mode. The derivatization was attempted directly in water sample without sample evaporation. The HF-LPME was performed using 1-octanol as the extracting solvent at 55 deg. C for 60 min with 20% Na 2 SO 4 . The linear calibration curves were observed for the concentrations ranging from 1 to 300 μg L -1 with the correlation coefficients (R 2 ) being greater than 0.99. The method detection limits of most analytes were below 1 μg L -1 except DCAA and MCAA that were 2 and 18 μg L -1 , respectively. The recoveries from spiked concentration ranged from 97 to 109% with %R.S.D. less than 12%. The method was applied for determination of HAAs in drinking water and tap water samples. The method offers an easy one step high sample throughput sample preparation for gas chromatographic determination of haloacetic acids as well as other contaminants in water

  7. Volatile hexafluoroacetylacetonates for the isolation and gas-chromatographic determination of trace metals. Pt. 1

    International Nuclear Information System (INIS)

    Hellmuth, K.H.; Mirzai, H.

    1985-01-01

    The optimization of the extraction of metal cations [Sc(III), Cr(III), Mn(II), Fe(III), Co(II), Cu(II), Zn(II), Y(III), Ag(I), Cd(II), La(IIII), Ce(III), Eu(III), Yb(III), Hg(II), Pb(II), Th(IV), U(IV, VI) and Am(III)] in the form of mixed-ligand complexes with hexafluoroacetylacetone and neutral donators with nitrogen atoms or P=O-groups is described. The thermal and gas-chromatographic characteristics of the extracted volatile compounds are reported. Optimal results were achieved using tri-n-butyl-phosphine oxide as donator. (orig.) [de

  8. Measurement method for benzene, toluene, and xylene in the atmosphere by the gas chromatographic method

    Energy Technology Data Exchange (ETDEWEB)

    Shiroyama, H

    1975-08-01

    The chromatographic method for measuring benzene, toluene, and xylene (three isomers) in the atmosphere was evaluated using the Varian model 2740-10 gas chromatograph. As a solvent, n-hexane was most suitable, and the detection limit was improved by increasing the purity of n-hexane. The calibration curves were prepared, the recovery rate was calculated (76.0-99.4 percent), and the correlation coefficient was obtained from regression curves (r equals 0.97-0.99). Samples collected at a naphtha cracking plant, an aluminum smelting mill, a pharmaceutical plant, a carbon electrode manufacturing plant, a plywood manufacturing plant, a plastic bathtub manufacturing plant, and along a major highway were analyzed. All three substances were detected in all samples with the concentration of toluene high compared to the other two. Among xylene isomers, the concentration of p-xylene was always the lowest while m- and o-xylene varied from place to place. In the atmosphere along the highway, the benzene, toluene, and xylene determined were 0.01-0.09 ppM. No benzene, toluene, and xylene were detected in atmospheric samples used as controls.

  9. Chromatographic and biological aspects of organomercurials

    Energy Technology Data Exchange (ETDEWEB)

    Fishbein, L

    1970-01-01

    A thorough review on the biological and chromatographic aspects of methylmercury, phenylmercurials, and miscellaneous organomercurials is presented. Areas covered include ecology, epidemiology, paper chromatography, thin-layer chromatography, gas chromatography, metabolism and toxicity, and environmental degradation. 183 references.

  10. Domestic Preparedness Program: Evaluation of the Agilent Gas Chromatograph - Flame Photometric Detector/Mass Selective Detector (GC-FPD/MSD) System Against Chemical Warfare Agents Summary Report

    National Research Council Canada - National Science Library

    Longworth, Terri

    2003-01-01

    This report characterizes the chemical warfare agent (CWA) detection potential of the commercially available Agilent gas chromatograph-flame photometric detector/mass selective detector (GC-FPD/MSD...

  11. Automated-process gas-chromatograph system for use in accelerated corrosion testing of HTGR core-support posts

    International Nuclear Information System (INIS)

    Harper, R.E.; Herndon, P.G.

    1982-01-01

    An automated-process gas chromatograph is the heart of a gaseous-impurities-analysis system developed for the Oak Ridge National Laboratory Core Support Performance Test, at which graphite core-support posts for high-temperature gas-cooled fission reactors are being subjected to accelerated corrosion tests under tightly controlled conditions of atmosphere and temperature. Realistic estimation of in-core corrosion rates is critically dependent upon the accurate measurement of low concentrations of CO, CO 2 , CH 4 , H 2 , and O 2 in the predominantly helium atmosphere. In addition, the capital and labor investment associated with each test puts a premium upon the reliability of the analytical system, as excessive downtime or failure to obtain accurate data would result in unacceptable costs and schedule delays. After an extensive survey of available measurement techniques, gas chromatography was chosen for reasons of accuracy, flexibility, good-performance record, and cost

  12. A high-throughput headspace gas chromatographic technique for the determination of nitrite content in water samples.

    Science.gov (United States)

    Zhang, Shu-Xin; Peng, Rong; Jiang, Ran; Chai, Xin-Sheng; Barnes, Donald G

    2018-02-23

    This paper reports on a high-throughput headspace gas chromatographic method (HS-GC) for the determination of nitrite content in water sample, based on GC measurement of cyclohexene produced from the reaction between nitrite and cyclamate in a closed vial. The method has a relative standard deviation of water samples. In short, the present HS-GC method is simple, accurate, and sensitive, and it is very suitable to be used in the batch sample testing. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Recent Advances in Water Analysis with Gas Chromatograph Mass Spectrometers

    Science.gov (United States)

    MacAskill, John A.; Tsikata, Edem

    2014-01-01

    We report on progress made in developing a water sampling system for detection and analysis of volatile organic compounds in water with a gas chromatograph mass spectrometer (GCMS). Two approaches are described herein. The first approach uses a custom water pre-concentrator for performing trap and purge of VOCs from water. The second approach uses a custom micro-volume, split-splitless injector that is compatible with air and water. These water sampling systems will enable a single GC-based instrument to analyze air and water samples for VOC content. As reduced mass, volume, and power is crucial for long-duration, manned space-exploration, these water sampling systems will demonstrate the ability of a GCMS to monitor both air and water quality of the astronaut environment, thereby reducing the amount of required instrumentation for long duration habitation. Laboratory prototypes of these water sampling systems have been constructed and tested with a quadrupole ion trap mass spectrometer as well as a thermal conductivity detector. Presented herein are details of these water sampling system with preliminary test results.

  14. Effects of γ-irradiation on caprolactam level from multilayer PA-6 films for food packaging: Development and validation of a gas chromatographic method

    International Nuclear Information System (INIS)

    Araujo, Henrique Peres; Felix, Juliana Silva; Manzoli, Jose Eduardo; Padula, Marisa; Monteiro, Magali

    2008-01-01

    A gas chromatographic method to determine caprolactam in multilayer PA-6 films used for meat foodstuffs and cheese was developed and validated. A wide linear range (0.8-400 μg/ml), RSD≤4.1% and recovery higher than 90.0% were obtained for the chromatographic system, while precision and accuracy of the method showed RSD≤3.8%, recovery from 95.5-100.0% and LOQ of 32 μg/g. Irradiated (3, 7 and 12 kGy) and non-irradiated commercial films were analyzed. Most of them increased caprolactam levels with the increase of irradiation doses

  15. Effects of {gamma}-irradiation on caprolactam level from multilayer PA-6 films for food packaging: Development and validation of a gas chromatographic method

    Energy Technology Data Exchange (ETDEWEB)

    Araujo, Henrique Peres; Felix, Juliana Silva [Department of Food and Nutrition, School of Pharmaceutical Science, Sao Paulo State University, PO Box 502, 14801-902 Araraquara, SP (Brazil); Manzoli, Jose Eduardo [Nuclear and Energetic Research Institute (IPEN), Sao Paulo, SP (Brazil); Padula, Marisa [Packaging Technology Center/Food Technology Institute (CETEA/ITAL), Campinas, SP (Brazil); Monteiro, Magali [Department of Food and Nutrition, School of Pharmaceutical Science, Sao Paulo State University, PO Box 502, 14801-902 Araraquara, SP (Brazil)], E-mail: monteiro@fcfar.unesp.br

    2008-07-15

    A gas chromatographic method to determine caprolactam in multilayer PA-6 films used for meat foodstuffs and cheese was developed and validated. A wide linear range (0.8-400 {mu}g/ml), RSD{<=}4.1% and recovery higher than 90.0% were obtained for the chromatographic system, while precision and accuracy of the method showed RSD{<=}3.8%, recovery from 95.5-100.0% and LOQ of 32 {mu}g/g. Irradiated (3, 7 and 12 kGy) and non-irradiated commercial films were analyzed. Most of them increased caprolactam levels with the increase of irradiation doses.

  16. On the ability of the Viking gas chromatograph-mass spectrometer to detect organic matter.

    Science.gov (United States)

    Biemann, Klaus

    2007-06-19

    A recent paper by Navarro-Gonzalez et al. [Navarro-Gonzalez R, Navarro KF, de la Rosa J, Iniguez E, Molina P, Miranda LD, Morales P, Cienfuegos E, Coll P, Raulin F, et al. (2006) Proc Natl Acad Sci USA 103:16089-16094] claims to show that the Viking GCMS (gas chromatograph-mass spectrometer) experiment, which carried out a search for organic matter at the surface of Mars in 1976, "may have been blind to low levels of organics." To rebut this assertion, the Viking experiment, test data, and results on Mars are reviewed, and the fallacies in the design, execution, and interpretation of the new experiments presented by Navarro-Gonzalez et al. are critically examined.

  17. Possibilities of gas-phase radio-chromatography application to permanent-gas analysis

    International Nuclear Information System (INIS)

    Dupuis, M.C.; Charrier, G.; Alba, C.; Massimino, D.

    1970-01-01

    The gas-phase radio-chromatography technique has been applied to the rapid analysis of permanent gases (H 2 , O 2 , N 2 , A, Kr, Xe, CO, CH 4 ) labelled with radioactive indicators ( 3 H, 37 A, 85 Kr, 133 Xe). After calibration, the components of such a mixture can be identified and their concentrations measured in less than two hours, using a sample volume of from 0.1 to 10 cm 3 . The minimum detectable activity is of the order of 10 -4 μC for each radioactive isotope. The measurements are reproducible to about 2 to 3 per cent. This work has been mainly concerned with the influence of parameters affecting the response of the radioactivity detector (ionization chamber or gas flow proportional counter). The method has very numerous applications both theoretically, for the study of chromatographic phenomena under ideal conditions (infinitesimal concentrations made possible by the use of radioactive tracers), and practically, for rapid and accurate radiochemical analysis of radioactive gas mixtures. (authors) [fr

  18. Authentication of commercial spices based on the similarities between gas chromatographic fingerprints.

    Science.gov (United States)

    Matsushita, Takaya; Zhao, Jing Jing; Igura, Noriyuki; Shimoda, Mitsuya

    2018-06-01

    A simple and solvent-free method was developed for the authentication of commercial spices. The similarities between gas chromatographic fingerprints were measured using similarity indices and multivariate data analyses, as morphological differentiation between dried powders and small spice particles was challenging. The volatile compounds present in 11 spices (i.e. allspice, anise, black pepper, caraway, clove, coriander, cumin, dill, fennel, star anise, and white pepper) were extracted by headspace solid-phase microextraction, and analysed by gas chromatography-mass spectrometry. The largest 10 peaks were selected from each total ion chromatogram, and a total of 65 volatiles were tentatively identified. The similarity indices (i.e. the congruence coefficients) were calculated using the data matrices of the identified compound relative peak areas to differentiate between two sets of fingerprints. Where pairs of similar fingerprints produced high congruence coefficients (>0.80), distinctive volatile markers were employed to distinguish between these samples. In addition, hierarchical cluster analysis and principal component analysis were performed to visualise the similarity among fingerprints, and the analysed spices were grouped and characterised according to their distinctive major components. This method is suitable for screening unknown spices, and can therefore be employed to evaluate the quality and authenticity of various spices. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  19. SIMULTANEOUS ANALYSIS OF AZIDOTHYMIDINE AND ITS MONOPHOSPHATE, DIPHOSPHATE AND TRIPHOSPHATE DERIVATIVES IN BIOLOGICAL-FLUIDS, TISSUE AND CULTURED-CELLS BY A RAPID HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD

    NARCIS (Netherlands)

    MOLEMA, G; JANSEN, RW; Visser, Jan; MEIJER, DKF

    1992-01-01

    A rapid high-performance liquid chromatographic (HPLC) method for the simultaneous analysis of the antiviral drug azidothymidine (AZT), AZT monophosphate, AZT diphosphate and AZT triphosphate, with ultraviolet detection in the nanomolar range, is described. Determination of these compounds in vitro

  20. Gas chromatographic-mass spectrometric analysis of biomarkers related to folate and cobalamin status in human serum after dimercaptopropanesulfonate reduction and heptafluorobutyl chloroformate derivatization

    Czech Academy of Sciences Publication Activity Database

    Šimek, Petr; Hušek, Petr; Zahradníčková, Helena

    2008-01-01

    Roč. 80, č. 15 (2008), s. 5776-5782 ISSN 0003-2700 R&D Projects: GA ČR GA303/06/1674 Institutional research plan: CEZ:AV0Z50070508 Keywords : biomarkers * gas chromatographic * chloroformate derivatization Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 5.712, year: 2008

  1. A multiresidue method by high performance liquid chromatography-based fractionation and gas chromatographic determination of trace levels of pesticides in air and water.

    Science.gov (United States)

    Seiber, J N; Glotfelty, D E; Lucas, A D; McChesney, M M; Sagebiel, J C; Wehner, T A

    1990-01-01

    A multiresidue analytical method is described for pesticides, transformation products, and related toxicants based upon high performance liquid chromatographic (HPLC) fractionation of extracted residue on a Partisil silica gel normal phase column followed by selective-detector gas chromatographic (GC) determination of components in each fraction. The HPLC mobile phase gradient (hexane to methyl t-butyl ether) gave good chromatographic efficiency, resolution, reproducibility and recovery for 61 test compounds, and allowed for collection in four fractions spanning polarities from low polarity organochlorine compounds (fraction 1) to polar N-methylcarbamates and organophosphorus oxons (fraction 4). The multiresidue method was developed for use with air samples collected on XAD-4 and related trapping agents, and water samples extracted with methylene chloride. Detection limits estimated from spiking experiments were generally 0.3-1 ng/m3 for high-volume air samples, and 0.01-0.1 microgram/L for one-liter water samples. Applications were made to determination of pesticides in fogwater and air samples.

  2. Determination and discrimination of biodiesel fuels by gas chromatographic and chemometric methods

    Science.gov (United States)

    Milina, R.; Mustafa, Z.; Bojilov, D.; Dagnon, S.; Moskovkina, M.

    2016-03-01

    Pattern recognition method (PRM) was applied to gas chromatographic (GC) data for a fatty acid methyl esters (FAME) composition of commercial and laboratory synthesized biodiesel fuels from vegetable oils including sunflower, rapeseed, corn and palm oils. Two GC quantitative methods to calculate individual fames were compared: Area % and internal standard. The both methods were applied for analysis of two certified reference materials. The statistical processing of the obtained results demonstrates the accuracy and precision of the two methods and allows them to be compared. For further chemometric investigations of biodiesel fuels by their FAME-profiles any of those methods can be used. PRM results of FAME profiles of samples from different vegetable oils show a successful recognition of biodiesels according to the feedstock. The information obtained can be used for selection of feedstock to produce biodiesels with certain properties, for assessing their interchangeability, for fuel spillage and remedial actions in the environment.

  3. Determination and discrimination of biodiesel fuels by gas chromatographic and chemometric methods

    Directory of Open Access Journals (Sweden)

    Milina R.

    2016-03-01

    Full Text Available Pattern recognition method (PRM was applied to gas chromatographic (GC data for a fatty acid methyl esters (FAME composition of commercial and laboratory synthesized biodiesel fuels from vegetable oils including sunflower, rapeseed, corn and palm oils. Two GC quantitative methods to calculate individual fames were compared: Area % and internal standard. The both methods were applied for analysis of two certified reference materials. The statistical processing of the obtained results demonstrates the accuracy and precision of the two methods and allows them to be compared. For further chemometric investigations of biodiesel fuels by their FAME-profiles any of those methods can be used. PRM results of FAME profiles of samples from different vegetable oils show a successful recognition of biodiesels according to the feedstock. The information obtained can be used for selection of feedstock to produce biodiesels with certain properties, for assessing their interchangeability, for fuel spillage and remedial actions in the environment.

  4. Isotope separations using chromatographic methods

    International Nuclear Information System (INIS)

    Leseticky, L.

    1985-01-01

    A survey is given of chromatographic separations of compounds only differing in isotope composition. Isotope effects on physical properties which allow chromatographic separation (vapour tension, adsorption heat, partition coefficient) are very small, with the exception of the simplest molecules. Therefore, separation factors only assume the value of several per cent. From this ensues the necessity of using columns which are specially and very carefully prepared and have a separation efficiency of the order of 10 4 theoretical plates. Briefly discussed is liquid chromatography on ion exchangers which with a varied degree of success was used for separating simple inorganic compounds or ions. Ion exchange chromatography of amino acids labelled with tritium, and chromatography of tritium labelled steroids also provided only a certain degree of separation. A detailed analysis is presented of gas chromatography separation of various deuterium and tritium labelled low-molecular compounds, to which a number of studies has been devoted in the literature. Very promising is the method of complexation gas chromatography based on the reversible formation of a complex of the ligand (the compound being separated) and the compound of the (transition) metal as the steady-state phase. (author)

  5. Gas--liquid chromatographic determination of total inorganic iodine in milk

    International Nuclear Information System (INIS)

    Bakker, H.J.

    1977-01-01

    Total inorganic iodine in milk is determined by conversion to iodobutanone, which is quantitated by gas-liquid chromatography and electron capture detection. As little as 10 μg/L can be determined. The thyroid-active iodine content of milk can be determined rapidly with a relative standard deviation of 1.9%. Average recoveries for added iodide and iodine were 95.5 and 94.6%, respectively

  6. Rapid determination of methadone and its major metabolite in biological fluids by gas-liquid chromatography with thermionic detection for maintenance treatment of opiate addicts.

    Science.gov (United States)

    Chikhi-Chorfi, N; Pham-Huy, C; Galons, H; Manuel, N; Lowenstein, W; Warnet, J M; Claude, J R

    1998-11-06

    A rapid gas-liquid chromatographic assay is developed for the quantification of methadone (Mtd) and its major metabolite, 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP), in biological fluids of opiate addicts. After alkaline extraction from samples with lidocaine hydrochloride as internal standard, Mtd and EDDP are separated on SP-2250 column at 220 degrees C and detected with a thermionic detector. The chromatographic time is about 6 min. The relative standard deviations (R.S.D.) of Mtd and EDDP standards are between 1.5 and 5.5%. Most drugs of abuse (morphine, codeine, narcotine, cocaine, benzoylecgonine, cocaethylene, dextropropoxyphene etc) are shown not to interfere with this technique. The method has been applied to study the levels of Mtd and EDDP metabolite in serum, saliva and urine of patients under maintenance treatment for opiate dependence. EDDP levels were found higher than those of Mtd in urine samples from four treated patients, but lower in serum and undetectable in saliva. However, Mtd concentrations were higher in saliva than in serum.

  7. Analysis and chromatographic purification of eicosanoids multiply labeled by tritium

    International Nuclear Information System (INIS)

    Shevchenko, V.P.; Nagaev, I.Yu.; Myasoedov, N.F.

    1989-01-01

    We show the possibility of analysis and chromatographic purification of eicosanoids triply labeled by tritium. The described methods allow us to isolate chromatographically pure products obtained by selective hydrogenatin, chemical, and enzyme methods, with radiochemical purity at least 95-97%. The following methods are used to analyze the reaction mixtures and to isolate the tritium-labeled eicosanoids: gas-liquid chromatography, high-efficiency liquid chromatography, and thin-layer chromatography on supports impregnated with silver nitrate

  8. Formation of hydrocarbons in irradiated Brazilian beans: gas chromatographic analysis to detect radiation processing

    International Nuclear Information System (INIS)

    Villavicencio, A.L.C.H.; Mancini-Filho, J.; Hartmann, M.; Ammon, J.; Delincee, H.

    1997-01-01

    Radiation processing of beans, which are a major source of dietary protein in Brazil, is a valuable alternative to chemical fumigation to combat postharvest losses due to insect infestation. To ensure free consumer choice, irradiated food will be labeled as such, and to enforce labeling, analytical methods to detect the irradiation treatment in the food product itself are desirable. In two varieties of Brazilian beans, Carioca and Macacar beans, the radiolytic formation of hydrocarbons formed after alpha and beta cleavage, with regard to the carbonyl group in triglycerides, have been studied. Using gas chromatographic analysis of these radiolytic hydrocarbons, different yields per precursor fatty acid are observed for the two types of beans. However, the typical degradation pattern allows the identification of the irradiation treatment in both bean varieties, even after 6 months of storage

  9. Characterisation of wax works of art by gas chromatographic procedures.

    Science.gov (United States)

    Regert, M; Langlois, J; Colinart, S

    2005-10-14

    To identify the various natural and synthetic substances used by sculptors at the end of the 19th century, several contemporary reference samples were investigated by high temperature gas chromatography (HT GC) and HT GC-MS. Using specific chromatographic conditions and minimising sample preparation, we could separate, detect and identify a wide range of biomolecular markers covering a great variety of molecular weights and volatilities, with a minimum amount of sample, in a single run. Beeswax, spermaceti, carnauba, candellila and Japan waxes as well as pine resin derivatives, animal fats, paraffin, ozokerite and stearin, used as additives in wax works of art, were chemically investigated. In the case of low volatile compounds, transbutylation was performed. The structure of long-chain esters of spermaceti was elucidated for the first time by HT GC-MS analysis. Such a method was then carried out on 10 samples collected on a statuette of Junon by Antoine-Louis Barye (Louvre Museum, Paris, France) and on a sculpture by Aimé-Jules Dalou (Musée de la Révolution Française, Vizille, France). The analytical results obtained provide new data on the complex recipes elaborated by sculptors at the end of the 19th century.

  10. Modified molecular sieves: stationary phase for the gas chromatographic separation of hydrogen isotopes

    International Nuclear Information System (INIS)

    Pushpa, K.K.; Annaji Rao, K.; Iyer, R.M.

    1993-01-01

    Gas chromatographic separation of hydrogen isotopes on different molecular sieves at liquid nitrogen temperature has been investigated. Normal molecular sieves 5A, 13X and AW500 are not satisfactory for the purpose both in the partially dehydrated as well as totally dehydrated state. Molecular sieve 4A in partially dehydrated state separated H 2 and D 2 while H 2 and HD are not well resolved. Iron exchanged or coated molecular sieves 4A, 5A, 13X and AW500 in the partially dehydrated state separated the isotopic mixtures H 2 , HD, D 2 and H 2 , HT, T 2 . The resolution varied depending on the amount of iron content and the residual moisture in the molecular sieves. Good separations were obtained on 15% Fe coated molecular sieve 5A and 5% Fe coated molecular sieve 4A. (author). 18 refs., 6 figs., 3 tabs

  11. Electrochemical reduction of phthalide at carbon cathodes in dimethylformamide: Effects of supporting electrolyte and gas chromatographic injector-port chemistry on the product distribution

    International Nuclear Information System (INIS)

    Pasciak, Erick M.; Hochstetler, Spencer E.; Mubarak, Mohammad S.; Evans, Dennis H.; Peters, Dennis G.

    2013-01-01

    Highlights: • Reduction of phthalide gives a radical-anion that undergoes ring-opening in 3.5 s. • Phthalide reduction gives 2-methylbenzoate esters with electrolyte-derived moieties. • Electrolysis of phthalide affords products that depend on the method of analysis. • Upon reduction, phthalide undergoes deuteration in the presence of deuterium oxide. -- Abstract: Cyclic voltammetry and controlled-potential (bulk) electrolysis have been used to investigate the direct reduction of phthalide at carbon electrodes in dimethylformamide (DMF) containing 0.10 M tetramethylammonium perchlorate (TMAP) or tetra-n-butylammonium perchlorate (TBAP). Cyclic voltammograms recorded with a glassy carbon electrode exhibit a single cathodic peak and a corresponding anodic peak that arise, respectively, from one-electron reduction of phthalide to generate a radical-anion intermediate and from reoxidation of the intermediate. At a scan rate of 100 mV s −1 , quasi-reversible behavior is observed (due to ring-opening of the radical-anion), whereas fully reversible behavior is seen at 5 V s −1 or higher. Digital simulation of cyclic voltammograms indicates that the lifetime of the radical-anion is 3.5 s. Bulk electrolysis of phthalide at a reticulated vitreous carbon cathode affords products that depend on the procedure used to analyze the catholyte. Direct injection of catholyte into a gas chromatograph shows phthalide and a 2-methylbenzoate ester bearing an alkyl moiety from the supporting-electrolyte cation. However, if the catholyte is partitioned between diethyl ether and aqueous hydrochloric acid before gas chromatographic analysis, phthalide and 2-methylbenzoic acid are observed. Thermally induced reactions that occur in the injector port of the gas chromatograph are responsible for the formation of the 2-methylbenzoate ester as well as for the phthalide found in all electrolyzed solutions

  12. Gas-liquid chromatographic determination of aniline metabolites of substituted urea and carbamate herbicides in aqueous solution.

    Science.gov (United States)

    Hargesheimer, E E; Coutts, R T; Pasutto, F M

    1981-07-01

    A simple gas-liquid chromatographic (GLC) method has been developed which provides sensitivity and specificity for the analysis of complex mixtures of the commonly occurring herbicide metabolites aniline, 3-chloroaniline, 4-chloroaniline, 4-bromoaniline, and 3-chloro-4-methylaniline. All of these anilines react with acetic anhydride directly in basified aqueous solution. Further reaction of the acetylated anilines with trifluoroacetic anhydride gave diacyl derivatives which were readily resolved by gas chromatography. The structures of the N-acetylated and N-trifluoroacetylated derivatives of benzylamine (internal standard) and the anilines were confirmed by GLC-mass spectrometry. In distilled water the minimum detectable concentrations of aniline and the substituted anilines, using electron capture GLC, are 0.1 nmole/100 mL and 0.05 nmole/100 mL, respectively. The detection limit for the anilines is 1 nmole/100 mL distilled water, using GLC with flame ionization detection. The technique was applied to the determination of anilines added to urine samples obtained from the general population.

  13. Towards the interaction between calcium carbide and water during gas-chromatographic determination of trace moisture in ultra-high purity ammonia.

    Science.gov (United States)

    Trubyanov, Maxim M; Mochalov, Georgy M; Suvorov, Sergey S; Puzanov, Egor S; Petukhov, Anton N; Vorotyntsev, Ilya V; Vorotyntsev, Vladimir M

    2018-05-16

    The current study focuses on the processes involved during the flow conversion of water into acetylene in a calcium carbide reaction cell for the trace moisture analysis of ammonia by reaction gas chromatography. The factors negatively affecting the reproducibility and the accuracy of the measurements are suggested and discussed. The intramolecular reaction of the HOCaCCH intermediate was found to be a side reaction producing background acetylene during the contact of wet ammonia gas with calcium carbide. The presence of the HOCaCCH intermediate among the reaction products is confirmed by an FTIR spectral study of calcium carbide powder exposed to wet gas. The side reaction kinetics is evaluated experimentally and its influence on the results of the gas chromatographic measurements is discussed in relation to the determination of the optimal operating parameters for ammonia analysis. The reaction gas chromatography method for the trace moisture measurements in an ammonia matrix was experimentally compared to an FTIR long-path length gas cell technique to evaluate the accuracy limitations and the resource intensity. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. A Gas Chromatographic Continuous Emissions Monitoring System for the Determination of VOCs and HAPs.

    Science.gov (United States)

    Coleman, William M; Gordon, Bert M

    1996-01-01

    This article describes a new gas chromatography-based emissions monitoring system for measuring volatile organic compounds (VOCs) and hazardous air pollutants (HAPs). The system is composed of a dual-column gas chromatograph equipped with thermal conductivity detectors, in which separation is optimized for fast chromatography. The system has the necessary valving for stream selection, which allows automatic calibration of the system at predetermined times and successive measurement of individual VOCs before and after a control device. Nine different VOCs (two of which are HAPs), plus methane (CH4) and carbon dioxide (CO2) are separated and quantified every two minutes. The accuracy and precision of this system has been demonstrated to be greater than 95%. The system employs a mass flow measurement device and also calculates and displays processed emission data, such as control device efficiency and total weight emitted during given time periods. Two such systems have been operational for one year in two separate gravure printing facilities; minimal upkeep is required, about one hour per month. One of these systems, used before and after a carbon adsorber, has been approved by the pertinent local permitting authority.

  15. Autonomous gas chromatograph system for Thermal Enhanced Vapor Extraction System (TEVES) proof of concept demonstration

    International Nuclear Information System (INIS)

    Peter, F.J.; Laguna, G.R.

    1996-09-01

    An autonomous gas chromatograph system was designed and built to support the Thermal Enhanced Vapor Extraction System (TEVES) demonstration. TEVES is a remediation demonstration that seeks to enhance an existing technology (vacuum extraction) by adding a new technology (soil heating). A pilot scale unit was set up at one of the organic waste disposal pits at the Sandia National Laboratories Chemical Waste Landfill (CWL) in Tech Area 3. The responsibility for engineering a major part of the process instrumentation for TEVES belonged to the Manufacturing Control Subsystems Department. The primary mission of the one-of-a-kind hardware/software system is to perform on-site gas sampling and analysis to quantify a variety of volatile organic compounds (VOCs) from various sources during TEVES operations. The secondary mission is to monitor a variety of TEVES process physical parameters such as extraction manifold temperature, pressure, humidity, and flow rate, and various subsurface pressures. The system began operation in September 1994 and was still in use on follow-on projects when this report was published

  16. Rapid process development of chromatographic process using direct analysis in real time mass spectrometry as a process analytical technology tool.

    Science.gov (United States)

    Yan, Binjun; Chen, Teng; Xu, Zhilin; Qu, Haibin

    2014-06-01

    The concept of quality by design (QbD) is widely applied in the process development of pharmaceuticals. However, the additional cost and time have caused some resistance about QbD implementation. To show a possible solution, this work proposed a rapid process development method, which used direct analysis in real time mass spectrometry (DART-MS) as a process analytical technology (PAT) tool for studying the chromatographic process of Ginkgo biloba L., as an example. The breakthrough curves were fast determined by DART-MS at-line. A high correlation coefficient of 0.9520 was found between the concentrations of ginkgolide A determined by DART-MS and HPLC. Based on the PAT tool, the impacts of process parameters on the adsorption capacity were discovered rapidly, which showed a decreased adsorption capacity with the increase of the flow rate. This work has shown the feasibility and advantages of integrating PAT into QbD implementation for rapid process development. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Rapid analysis of dissolved methane, ethylene, acetylene and ethane using partition coefficients and headspace-gas chromatography.

    Science.gov (United States)

    Lomond, Jasmine S; Tong, Anthony Z

    2011-01-01

    Analysis of dissolved methane, ethylene, acetylene, and ethane in water is crucial in evaluating anaerobic activity and investigating the sources of hydrocarbon contamination in aquatic environments. A rapid chromatographic method based on phase equilibrium between water and its headspace is developed for these analytes. The new method requires minimal sample preparation and no special apparatus except those associated with gas chromatography. Instead of Henry's Law used in similar previous studies, partition coefficients are used for the first time to calculate concentrations of dissolved hydrocarbon gases, which considerably simplifies the calculation involved. Partition coefficients are determined to be 128, 27.9, 1.28, and 96.3 at 30°C for methane, ethylene, acetylene, and ethane, respectively. It was discovered that the volume ratio of gas-to-liquid phase is critical to the accuracy of the measurements. The method performance can be readily improved by reducing the volume ratio of the two phases. Method validation shows less than 6% variation in accuracy and precision except at low levels of methane where interferences occur in ambient air. Method detection limits are determined to be in the low ng/L range for all analytes. The performance of the method is further tested using environmental samples collected from various sites in Nova Scotia.

  18. Micro-column plasma emission liquid chromatograph. [Patent application

    Science.gov (United States)

    Gay, D.D.

    1982-08-12

    In a direct current plasma emission spectrometer for use in combination with a microcolumn liquid chromatograph, an improved plasma source unit is claimed. The plasma source unit includes a quartz capillary tube having an inlet means, outlet off gas means and a pair of spaced electrodes defining a plasma region in the tube. The inlet means is connected to and adapted to receive eluant of the liquid chromatograph along with a stream of plasma-forming gas. There is an opening through the wall of the capillary tube penetrating into the plasma region. A soft glass capillary light pipe is disposed at the opening, is connected to the spectrometer, and is adapted to transmit light passing from the plasma region to the spectrometer. There is also a source of electromotive force connected to the electrodes sufficient to initiate and sustain a plasma in the plasma region of the tube.

  19. Rapid estimation of the organic sulphur content of kerogens, coals and asphaltenes by pyrolysis-gas chromatography

    NARCIS (Netherlands)

    Sinninghe Damsté, J.S.; Eglinton, T.I.; Kohnen, M.E.L.; Leeuw, J.W. de

    1990-01-01

    A pyrolysis-gas Chromatographic (py-g.c.) method for estimation of the Sorg/C ratio in kerogens and other forms of sedimentary macromolecular organic matter is described. The method is based upon flash pyrolysis at 610 °C for 10s and areal integration of the FID peaks attributed to

  20. Miniaturized chromatographic radiochemical procedure for 131I - MIBG

    International Nuclear Information System (INIS)

    Barboza, M.F. de; Pereira, N.S. de; Colturato, M.T.; Silva, C.P.G. da.

    1989-12-01

    Different solvents were used in paper chromatographic methods to obtain the best system in routine radiochemical control for 131 I-MIBG produced at IPEN-CNEN/SP. The dates were compared with those obtained with eletrophoresis method in buffer acetate, pH=4.5, 350V, during 40 minutes. The stability of the labeled compound store under 4 0 C was studied during 15 days. Miniaturized chromatographic procedures were established using Whatman 3MM (8x1cm) and n-butanol-:acetic acid: water (S:2:1) as a solvent. the Rf values were: 0.3 (I - ) and 1.0 (MIBG). The radiochemical purity was 99.3 and 99.2% (first day) obtained with eletrophoresis and miniaturized chromatographic procedures, respectively and, 84.7% after 15 days of its preparation. It is a rapid, practical and reproductive method. (author) [pt

  1. Headspace solid-phase microextraction procedures for gas chromatographic analysis of biological fluids and materials.

    Science.gov (United States)

    Mills, G A; Walker, V

    2000-12-01

    Solid-phase microextraction (SPME) is a new solventless sample preparation technique that is finding wide usage. This review provides updated information on headspace SPME with gas chromatographic separation for the extraction and measurement of volatile and semivolatile analytes in biological fluids and materials. Firstly the background to the technique is given in terms of apparatus, fibres used, extraction conditions and derivatisation procedures. Then the different matrices, urine, blood, faeces, breast milk, hair, breath and saliva are considered separately. For each, methods appropriate for the analysis of drugs and metabolites, solvents and chemicals, anaesthetics, pesticides, organometallics and endogenous compounds are reviewed and the main experimental conditions outlined with specific examples. Then finally, the future potential of SPME for the analysis of biological samples in terms of the development of new devices and fibre chemistries and its coupling with high-performance liquid chromatography is discussed.

  2. In-line gas chromatographic apparatus for measuring the hydrophobic micropore volume (HMV) and contaminant transformation in mineral micropores

    Energy Technology Data Exchange (ETDEWEB)

    Cheng Hefa [State Key Laboratory of Organic Geochemistry, Guangzhou Institute of Geochemistry, Chinese Academy of Sciences, Guangzhou 510640 (China); Reinhard, Martin, E-mail: reinhard@stanford.edu [Department of Civil and Environmental Engineering, Stanford University, Stanford, CA 94305-4020 (United States)

    2010-07-15

    Desorption of hydrophobic organic compounds from micropores is characteristically slow compared to surface adsorption and partitioning. The slow-desorbing mass of a hydrophobic probe molecule can be used to calculate the hydrophobic micropore volume (HMV) of microporous solids. A gas chromatographic apparatus is described that allows characterization of the sorbed mass with respect to the desorption rate. The method is demonstrated using a dealuminated zeolite and an aquifer sand as the model and reference sorbents, respectively, and trichloroethylene (TCE) as the probe molecule. A glass column packed with the microporous sorbent is coupled directly to a gas chromatograph that is equipped with flame ionization and electron capture detectors. Sorption and desorption of TCE on the sorbent was measured by sampling the influent and effluent of the column using a combination of switching and injection valves. For geosorbents, the HMV is quantified based on Gurvitsch's rule from the mass of TCE desorbed at a rate that is characteristic for micropores. Instrumental requirements, design considerations, hardware details, detector calibration, performance, and data analysis are discussed along with applications. The method is novel and complements traditional vacuum gravimetric and piezometric techniques, which quantify the total pore volume under vacuum conditions. The HMV is more relevant than the total micropore volume for predicting the fate and transport of organic contaminants in the subsurface. Sorption in hydrophobic micropores strongly impacts the mobility of organic contaminants, and their chemical and biological transformations. The apparatus can serve as a tool for characterizing microprous solids and investigating contaminant-solid interactions.

  3. In-line gas chromatographic apparatus for measuring the hydrophobic micropore volume (HMV) and contaminant transformation in mineral micropores

    International Nuclear Information System (INIS)

    Cheng Hefa; Reinhard, Martin

    2010-01-01

    Desorption of hydrophobic organic compounds from micropores is characteristically slow compared to surface adsorption and partitioning. The slow-desorbing mass of a hydrophobic probe molecule can be used to calculate the hydrophobic micropore volume (HMV) of microporous solids. A gas chromatographic apparatus is described that allows characterization of the sorbed mass with respect to the desorption rate. The method is demonstrated using a dealuminated zeolite and an aquifer sand as the model and reference sorbents, respectively, and trichloroethylene (TCE) as the probe molecule. A glass column packed with the microporous sorbent is coupled directly to a gas chromatograph that is equipped with flame ionization and electron capture detectors. Sorption and desorption of TCE on the sorbent was measured by sampling the influent and effluent of the column using a combination of switching and injection valves. For geosorbents, the HMV is quantified based on Gurvitsch's rule from the mass of TCE desorbed at a rate that is characteristic for micropores. Instrumental requirements, design considerations, hardware details, detector calibration, performance, and data analysis are discussed along with applications. The method is novel and complements traditional vacuum gravimetric and piezometric techniques, which quantify the total pore volume under vacuum conditions. The HMV is more relevant than the total micropore volume for predicting the fate and transport of organic contaminants in the subsurface. Sorption in hydrophobic micropores strongly impacts the mobility of organic contaminants, and their chemical and biological transformations. The apparatus can serve as a tool for characterizing microprous solids and investigating contaminant-solid interactions.

  4. In-line gas chromatographic apparatus for measuring the hydrophobic micropore volume (HMV) and contaminant transformation in mineral micropores.

    Science.gov (United States)

    Cheng, Hefa; Reinhard, Martin

    2010-07-15

    Desorption of hydrophobic organic compounds from micropores is characteristically slow compared to surface adsorption and partitioning. The slow-desorbing mass of a hydrophobic probe molecule can be used to calculate the hydrophobic micropore volume (HMV) of microporous solids. A gas chromatographic apparatus is described that allows characterization of the sorbed mass with respect to the desorption rate. The method is demonstrated using a dealuminated zeolite and an aquifer sand as the model and reference sorbents, respectively, and trichloroethylene (TCE) as the probe molecule. A glass column packed with the microporous sorbent is coupled directly to a gas chromatograph that is equipped with flame ionization and electron capture detectors. Sorption and desorption of TCE on the sorbent was measured by sampling the influent and effluent of the column using a combination of switching and injection valves. For geosorbents, the HMV is quantified based on Gurvitsch's rule from the mass of TCE desorbed at a rate that is characteristic for micropores. Instrumental requirements, design considerations, hardware details, detector calibration, performance, and data analysis are discussed along with applications. The method is novel and complements traditional vacuum gravimetric and piezometric techniques, which quantify the total pore volume under vacuum conditions. The HMV is more relevant than the total micropore volume for predicting the fate and transport of organic contaminants in the subsurface. Sorption in hydrophobic micropores strongly impacts the mobility of organic contaminants, and their chemical and biological transformations. The apparatus can serve as a tool for characterizing microporous solids and investigating contaminant-solid interactions. 2010 Elsevier B.V. All rights reserved.

  5. Gas chromatographic determination of residual hydrazine and morpholine in boiler feed water and steam condensates

    International Nuclear Information System (INIS)

    Vatsala, S.; Bansal, V.; Tuli, D.K.; Rai, M.M.; Jain, S.K.; Srivastava, S.P.; Bhatnagar, A.K.

    1994-01-01

    Hydrazine, an oxygen scavenger in boiler water, was derivatised to the corresponding acetone azine and determined at the ng ml -1 level by gas chromatography. Morpholine, a corrosion inhibitor used in steam boilers, was estimated either directly (if >2.0 μg ml -1 ) or by quantitative preconcentration (0.1 ng-2.0 μg ml -1 ). To obtain symmetrical peaks for these amines, the column packing was coated with KOH. Use of a nitrogen-specific detector improved accuracy of estimation of hydrazine and morpholine, giving a RSD of 1.9-3.6%. Chromatographic analysis of these amines in boiler feed water and steam condensate samples collected from boilers servicing a pertroleum refinery is described. Environmental safety regulations calls for monitoring of hydrazine and the methods developed can easily be adapted for this purpose. (orig.)

  6. Gas chromatographic determination of yohimbine in commercial yohimbe products.

    Science.gov (United States)

    Betz, J M; White, K D; der Marderosian, A H

    1995-01-01

    The bark of Pausinystalia yohimbe [K. Schumann] Pierre (Rubiaceae), long valued as an aphrodisiac in West Africa, recently has been promoted in the United States as a dietary supplement alternative to anabolic steroids for enhancement of athletic performance. As the number of yohimbe products on the retail market increases, concerns about their safety are raised because of the reported toxicity of yohimbine (the major alkaloid of the plant). Although plant materials are usually identified microscopically, we were unable to identify them in many of the products, because as their labels indicated, the products were mixtures of various botanicals or were bark extracts and contained little or no plant material. A method for extraction and capillary gas chromatographic (GC) separation of the alkaloids of P. yohimbe was, therefore, developed and used to analyze a number of commercial yohimbe products. The method involved solvent extraction and partitioning in chloroform-water followed by separation on a methyl silicone capillary GC column (N-P detection). Comparisons of chromatograms of extracts of authentic bark with those of commercial products indicated that, although many products contained measurable quantities of the alkaloid yohimbine, they were largely devoid of the other alkaloids previously reported in this species. Concentrations of yohimbine in the commercial products ranged from < 0.1 to 489 ppm, compared with 7089 ppm in the authentic material. Authentic bark has been reported to contain up to 6% total alkaloids, 10-15% of which are yohimbine. The possible presence of undeclared diluents in the products was indicated by peaks in product chromatograms but not in those of authentic bark.

  7. Equations for nickel-chromium wire heaters of column transfer lines in gas chromatographic-electroantennographic detection (GC-EAD).

    Science.gov (United States)

    Byers, John A

    2004-05-30

    Heating of chromatographic columns, transfer lines, and other devices is often required in neuroscience research. For example, volatile compounds passing through a capillary column of a gas chromatograph (GC) can be split, with half exiting the instrument through a heated transfer line to an insect antenna or olfactory sensillum for electroantennographic detector (GC-EAD) recordings. The heated transfer line is used to prevent condensation of various chemicals in the capillary that would otherwise occur at room temperature. Construction of such a transfer line heater is described using (80/20%) nickel-chromium heating wire wrapped in a helical coil and powered by a 120/220 V ac rheostat. Algorithms were developed in a computer program to estimate the voltage at which a rheostat should be set to obtain the desired heater temperature for a specific coil. The coil attributes (radius, width, number of loops, or length of each loop) are input by the user, as well as AWG size of heating wire and desired heater temperature. The program calculates total length of wire in the helix, resistance of the wire, amperage used, and the voltage to set the rheostat. A discussion of semiochemical isolation methods using the GC-EAD and bioassays is presented.

  8. Gas chromatography at the Tritium Laboratory Karlsruhe

    International Nuclear Information System (INIS)

    Laesser, R.; Gruenhagen, S.

    2003-08-01

    Among the analytical techniques (mass spectrometry, laser Raman spectroscopy, gas chromatography, use of ionisation chambers) employed at the Tritium Laboratory Karlsruhe (TLK), gas chromatography plays a prominent role. The main reasons for that are the simplicity of the gas chromatographic separation process, the small space required for the equipment, the low investment costs in comparison to other methods, the robustness of the equipment, the simple and straightforward analysis and the fact that all gas species of interest (with the exception of water) can easily be detected by gas chromatographic means. The conventional gas chromatographs GC1 and GC2 used in the Tritium Measurement Techniques (TMT) System of the TLK and the gas chromatograph GC3 of the experiment CAPER are presented in detail, by discussing their flow diagrams, their major components, the chromatograms measured by means of various detectors, shortcomings and possible improvements. One of the main disadvantages of the conventional gas chromatography is the long retention times required for the analysis of hydrogen gas mixtures. To overcome this disadvantage, micro gas chromatography for hydrogen analysis was developed. Reduction of the retention times by one order of magnitude was achieved. (orig.)

  9. A Rapid Process for Fabricating Gas Sensors

    Directory of Open Access Journals (Sweden)

    Chun-Ching Hsiao

    2014-07-01

    Full Text Available Zinc oxide (ZnO is a low-toxicity and environmentally-friendly material applied on devices, sensors or actuators for “green” usage. A porous ZnO film deposited by a rapid process of aerosol deposition (AD was employed as the gas-sensitive material in a CO gas sensor to reduce both manufacturing cost and time, and to further extend the AD application for a large-scale production. The relative resistance change (△R/R of the ZnO gas sensor was used for gas measurement. The fabricated ZnO gas sensors were measured with operating temperatures ranging from 110 °C to 180 °C, and CO concentrations ranging from 100 ppm to 1000 ppm. The sensitivity and the response time presented good performance at increasing operating temperatures and CO concentrations. AD was successfully for applied for making ZnO gas sensors with great potential for achieving high deposition rates at low deposition temperatures, large-scale production and low cost.

  10. Covalently coating dextran on macroporous polyglycidyl methacrylate microsphere enabled rapid protein chromatographic separation

    International Nuclear Information System (INIS)

    Zhang, Rongyue; Li, Qiang; Li, Juan; Zhou, Weiqing; Ye, Peili; Gao, Yang; Ma, Guanghui; Su, Zhiguo

    2012-01-01

    Protein denaturation and nonspecific adsorption on polymer media as a chromatographic support have been a problem which needs to be overcome. Macroporous poly(glycidyl methacrylate–divinylbezene) (PGMA–DVB) microspheres prepared in this study were firstly covalently coated with dextran through a three-step method. The dextran was firstly adsorbed onto the microspheres and then covalently bound to the PGMA–DVB microsphere through ether bonds which were formed by hydroxyl group reacting with epoxy group at the presence of 4-(Dimethylamino) pyridine. Finally, the coating dextran layer was crosslinked by ethylene glycol diglycidyl ether to form the continuous network coating. The coated microspheres were characterized by Fourier transform infrared spectra, scanning electron microscope, mercury porosimetry measurements, laser scanning confocal microscope, and protein adsorption experiments. Results showed that PGMA–DVB microspheres coated with dextran successfully maintained the macroporous structure and high permeability. The backpressure was only 1.69 MPa at a high flow rate of 2891 cm/h. Consequently, the hydrophilicity and biocompatibility of modified microspheres were greatly improved, and the contact angle decreased from 184° to 13°, and nonspecific adsorption of proteins was decreased to little or none. The clad dextran coating with large amounts of hydroxyl group was easily derived to be various functional groups. The derived media have great potential applications in rapid protein chromatography. - Highlights: ► Macroporous PGMA–DVB microspheres were covalently coated with dextran. ► The hydrophilicity of the coated microspheres was significantly improved. ► The irreversible adsorption of proteins was reduced to zero. ► The coated microspheres can maintain the macropore structure. ► The coated microspheres were applied to rapid protein separation.

  11. Gas Chromatographic Mass Spectrometric Determination of Myo-inositol in Humans Utilizing a Deuterated Internal Standard

    DEFF Research Database (Denmark)

    Andersen, Jan Rud; Larsen, Elfinn; Harbo, Helge

    1982-01-01

    The isotopic dilution technique was used for determining the content of myo-inositol in human urine, plasma and haemolysed erythrocyte samples. A deuterated myo-inositol, synthesized from inosose-2 by base-catalysed exchange of hydrogens by deuterium, followed by reduction of the inosose with 2H2......, was added as internal standard to the samples at an early stage in the analytical procedure. After separation and derivatization to the hexa-acetate, the gas chromatographic mass spectrometric analysis was carried out. A 25 m fused silica capillary column coated with methyl silicone was used, and the ions...... selected for monitoring were m/z 210 and m/z 214, which are characteristic and abundant fragment ions from unlabelled and hexadeuterated myo-inositolhexa-acetate, respectively. Calibration curves from water, urine, plasma and haemolysed erythrocytes show parallel, linear responses in the ratio between...

  12. Rapid gas development in the Fayetteville shale basin, Arkansas

    Science.gov (United States)

    Advances in drilling and extraction of natural gas have resulted in rapid expansion of wells in shale basins. The rate of gas well installation in the Fayetteville shale is 774 wells a year since 2005 with thousands more planned. The Fayetteville shale covers 23,000 km2 although ...

  13. Use of adsorption and gas chromatographic techniques in estimating biodegradation of indigenous crude oils

    International Nuclear Information System (INIS)

    Kokub, D.; Allahi, A.; Shafeeq, M.; Khalid, Z.M.; Malik, K.A.; Hussain, A.

    1993-01-01

    Indigenous crude oils could be degraded and emulsified upto varying degree by locally isolated bacteria. Degradation and emulsification was found to be dependent upon the chemical composition of the crude oils. Tando Alum and Khashkheli crude oils were emulsified in 27 and 33 days of incubation respectively. While Joyamair crude oil and not emulsify even mainly due to high viscosity of this oil. Using adsorption chromatographic technique, oil from control (uninoculated) and bio degraded flasks was fractioned into the deasphaltened oil containing saturate, aromatic, NSO (nitrogen, sulphur, oxygen) containing hydrocarbons) and soluble asphaltenes. Saturate fractions from control and degraded oil were further analysed by gas liquid chromatography. From these analyses, it was observed that saturate fraction was preferentially utilized and the crude oils having greater contents of saturate fraction were better emulsified than those low in this fraction. Utilization of various fractions of crude oils was in the order saturate> aromatic> NSO. (author)

  14. Incident at university research facility - melt down of gas chromatograph evaporation block and failure of a passive safety barrier

    DEFF Research Database (Denmark)

    Jensen, Niels; Jørgensen, Sten Bay

    2014-01-01

    Two incidents are described highlighting the importance of process hazard analysis in university laboratories. In the first incident, an online gas chromatograph (GC) was being developed. A complete meltdown of the heating blog was experienced during testing because the PC had failed to turn off...... the heating of the evaporation circuit. There had been no design review of the GC, nor any code review of the software controlling the GC. Neither had there been any management of change review for the introduction of the GC in the pilot plant environment, and so the GC had been introduced without any...

  15. Capillary gas chromatographic analysis of nerve agents using large volume injections. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Deinum, T.; Nieuwenhuy, C.

    1994-11-01

    The procedure developed at TNO-Prins Maurits Laboratory (TNO-PML) for the verification of intact organophosphorus chemical warfare agents in water samples was improved. The last step in this procedure, the laborious and non-reproducible transfer of an ethyl acetate extract onto a Tenax-adsorption tube followed by thermal desorption of the Tenax-tube, was replaced by large volume injection of the extract onto a capillary gas chromatographic system. The parameters controlling the injection of a large volume of an extract (200 ul) were investigated and optimized. As ethyl acetate caused severe problems, potential new solvents were evaluated. With the improved procedure, the nerve agents sarin, tabun, soman, diisopropyl fluorophosphate (DFP) and VX could be determined in freshly prepared water samples at pg/ml (ppt) levels. The fate of the nerve agents under study in water at two pH`s (4.8 and 6) was investigated. For VX, the pH should be adjusted before extraction. Moreover, it is worthwhile to acidify water samples to diminish hydrolysis.

  16. Covalently coating dextran on macroporous polyglycidyl methacrylate microsphere enabled rapid protein chromatographic separation

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Rongyue; Li, Qiang; Li, Juan; Zhou, Weiqing; Ye, Peili; Gao, Yang; Ma, Guanghui, E-mail: ghma@home.ipe.ac.cn; Su, Zhiguo

    2012-12-01

    Protein denaturation and nonspecific adsorption on polymer media as a chromatographic support have been a problem which needs to be overcome. Macroporous poly(glycidyl methacrylate-divinylbezene) (PGMA-DVB) microspheres prepared in this study were firstly covalently coated with dextran through a three-step method. The dextran was firstly adsorbed onto the microspheres and then covalently bound to the PGMA-DVB microsphere through ether bonds which were formed by hydroxyl group reacting with epoxy group at the presence of 4-(Dimethylamino) pyridine. Finally, the coating dextran layer was crosslinked by ethylene glycol diglycidyl ether to form the continuous network coating. The coated microspheres were characterized by Fourier transform infrared spectra, scanning electron microscope, mercury porosimetry measurements, laser scanning confocal microscope, and protein adsorption experiments. Results showed that PGMA-DVB microspheres coated with dextran successfully maintained the macroporous structure and high permeability. The backpressure was only 1.69 MPa at a high flow rate of 2891 cm/h. Consequently, the hydrophilicity and biocompatibility of modified microspheres were greatly improved, and the contact angle decreased from 184 Degree-Sign to 13 Degree-Sign , and nonspecific adsorption of proteins was decreased to little or none. The clad dextran coating with large amounts of hydroxyl group was easily derived to be various functional groups. The derived media have great potential applications in rapid protein chromatography. - Highlights: Black-Right-Pointing-Pointer Macroporous PGMA-DVB microspheres were covalently coated with dextran. Black-Right-Pointing-Pointer The hydrophilicity of the coated microspheres was significantly improved. Black-Right-Pointing-Pointer The irreversible adsorption of proteins was reduced to zero. Black-Right-Pointing-Pointer The coated microspheres can maintain the macropore structure. Black-Right-Pointing-Pointer The coated microspheres

  17. Transformation kinetics of chlorinated ethenes by Methylosinus trichosporium OB3b and detection of unstable epoxides by on-line gas chromatography

    NARCIS (Netherlands)

    van Hylckama Vlieg, Johan. E.T.; Koning, Wim de; Janssen, Dick B.

    A rapid and accurate method for the determination of transformation kinetics of volatile organic substrates was developed. Concentrations were monitored by on-line gas chromatographic analysis of the headspace of well-mixed incubation mixtures. With this method, the kinetics of transformation of a

  18. Evaluation of a gas chromatograph with a novel surface acoustic wave detector (SAW GC) for screening of volatile organic compounds in Hanford waste tank samples

    International Nuclear Information System (INIS)

    Lockrem, L.L.

    1998-01-01

    A novel instrument, a gas chromatograph with a Surface Acoustic Wave Detector (SAW GC), was evaluated for the screening of organic compounds in Hanford tank headspace vapors. Calibration data were developed for the most common organic compounds, and the accuracy and precision were measured with a certified standard. The instrument was tested with headspace samples collected from seven Hanford waste tanks

  19. Gas chromatographic analysis of dimethyltryptamine and beta-carboline alkaloids in ayahuasca, an Amazonian psychoactive plant beverage.

    Science.gov (United States)

    Pires, Ana Paula Salum; De Oliveira, Carolina Dizioli Rodrigues; Moura, Sidnei; Dörr, Felipe Augusto; Silva, Wagner Abreu E; Yonamine, Mauricio

    2009-01-01

    Ayahuasca is obtained by infusing the pounded stems of Banisteriopsis caapi in combination with the leaves of Psychotria viridis. P. viridis is rich in the psychedelic indole N,N-dimethyltryptamine, whereas B. caapi contains substantial amounts of beta-carboline alkaloids, mainly harmine, harmaline and tetrahydroharmine, which are monoamine-oxidase inhibitors. Because of differences in composition in ayahuasca preparations, a method to measure their main active constituents is needed. To develop a gas chromatographic method for the simultaneous determination of dimethyltryptamine and the main beta-carbolines found in ayahuasca preparations. The alkaloids were extracted by means of solid phase extraction (C(18)) and detected by gas chromatography with nitrogen/phosphorous detector. The lower limit of quantification (LLOQ) was 0.02 mg/mL for all analytes. The calibration curves were linear over a concentration range of 0.02-4.0 mg/mL (r(2 )> 0.99). The method was also precise (RSD ayahuasca was developed and validated. The method can be useful to estimate administered doses in animals and humans for further pharmacological and toxicological investigations of ayahuasca. Copyright (c) 2009 John Wiley & Sons, Ltd.

  20. Evaluation of rapid immuno chromatographic assay kit using monoclonal mpt64 antibodies for identification of mycobacterium tuberculosis complex

    International Nuclear Information System (INIS)

    Satti, L.; Ikram, A.; Malik, N.

    2010-01-01

    To evaluate the performance of rapid immuno chromatographic kit MPT64 Ag for the identification of Mycobacterium tuberculosis complex from various Mycobacterium tuberculosis culture positive specimens. Department of Microbiology, Armed Forces Institute of Pathology Rawalpindi, from August 2008 through March 2009. Eighty four Mycobacterium tuberculosis positive cultures on I BACTEC 460 and MGIT 960, one ATCC 25177 MTB strain, three institutional control MTB strains, two institutional control MOTT strains and 20 different bacterial isolates were tested. Tests were performed according to the instructional manual. Out of total 84 tested samples, MPT64 showed positive result in 80 cultures. Only four positive cultures did not display any band on MPT64 kit. These four strains were reconfirmed as Mycobacterium tuberculosis by PCR method. MOTT control strains and all the 20 bacterial isolates were negative for band. The sensitivity and specificity of ICT assay in our study was 95.2% and 100% respectively. Rapid MPT64 Kit is a good diagnostic tool to differentiate between Mycobacterium tuberculosis complex and MOTT with 100% specificity. The technique is simple and can provide prompt information to the clinicians to initiate early and appropriate antituberculosis therapy. (author)

  1. Gas-chromatographic separation of hydrogen isotopes mixtures on capillary molecular sieve 5 A column at 173 K

    International Nuclear Information System (INIS)

    Bidica, N.; Preda, A.; Stanciu, V.

    2002-01-01

    Analysis of a gas mixture of hydrogen species, is not too easy because the differences in their physical-chemical properties are very small; the most different are their masses, and consequently most common analytical method appear to be the mass-spectrometry. However, the impossibility to distinguish between two ions (atomic or molecular) with the same mass renders this method as unapplicable. Another problem is the decay of tritium with production of 3 He. These disadvantages of mass-spectrometry have made that other analytical methods, like gas chromatography, to be considered and developed. Thus, there are many papers about various chromatographic columns especially prepared for hydrogen species separation but the preparation and treatment of these columns are very difficult to reproduce. Besides these, there are two other main disadvantages: column operating temperature is very low and long retention times for hydrogen species (more than half an hour) are required. However, the gas-chromatography method still remains an appropriate one. The method described in this paper was based on using a capillary molecular sieve 5A column which has been operated for this kind of separation. The retention times were relatively short, about 8-9 minutes. The carrier gas was Ne and the detector - TCD. In the paper chromatograms for various carrier flow rates and various hydrogen isotope mixtures are presented. The results demonstrated a quite good efficiency for H 2 , HD, D 2 and a not very good one for orthoH 2 -paraH 2 . (authors)

  2. Volatilizable Biogenic Organic Compounds (VBOCs with two dimensional Gas Chromatography-Time of Flight Mass Spectrometry (GC × GC-TOFMS: sampling methods, VBOC complexity, and chromatographic retention data

    Directory of Open Access Journals (Sweden)

    C. Chen

    2012-02-01

    Full Text Available Two dimensional gas chromatography (GC × GC with detection by time-of-flight mass spectrometry (TOFMS was applied in the rapid analysis of air samples containing highly complex mixtures of volatilizable biogenic organic compounds (VBOCs. VBOC analytical methodologies are briefly reviewed, and optimal conditions are discussed for sampling with both adsorption/thermal desorption (ATD cartridges and solid-phase microextraction (SPME fibers. Air samples containing VBOC emissions from leaves of two tree species (Cedrus atlantica and Calycolpus moritzianus were obtained by both ATD and SPME. The optimized gas chromatographic conditions utilized a 45 m, 0.25 mm I.D. low-polarity primary column (DB-VRX, 1.4 μm film and a 1.5 m, 0.25 mm I.D. polar secondary column (StabilwaxTM, 0.25 μm film. Excellent separation was achieved in a 36 min temperature programmed GC × GC chromatogram. Thousands of VBOC peaks were present in the sample chromatograms; hundreds of tentative identifications by NIST mass spectral matching are provided. Very few of the tentatively identified compounds are currently available as authentic standards. Minimum detection limit values for a 5 l ATD sample were 3.5 pptv (10 ng m−3 for isoprene, methyl vinyl ketone, and methacrolein, and ~1.5 pptv (~10 ng m−3 for monoterpenes and sesquiterpenes. Kovats-type chromatographic retention index values on the primary column and relative retention time values on the secondary column are provided for 21 standard compounds and for 417 tentatively identified VBOCs. 19 of the 21 authentic standard compounds were found in one of the Cedrus atlantica SPME samples. In addition, easily quantifiable levels of at least 13 sesquiterpenes were found in an ATD sample obtained from a branch enclosure of Calycolpus moritzianus. Overall, the results obtained via GC × GC-TOFMS highlight an extreme, and largely uncharacterized diversity of VBOCs, consistent with the hypothesis that sesquiterpenes and

  3. Volatilizable Biogenic Organic Compounds (VBOCs) with two dimensional Gas Chromatography-Time of Flight Mass Spectrometry (GC × GC-TOFMS): sampling methods, VBOC complexity, and chromatographic retention data

    Science.gov (United States)

    Pankow, J. F.; Luo, W.; Melnychenko, A. N.; Barsanti, K. C.; Isabelle, L. M.; Chen, C.; Guenther, A. B.; Rosenstiel, T. N.

    2012-02-01

    Two dimensional gas chromatography (GC × GC) with detection by time-of-flight mass spectrometry (TOFMS) was applied in the rapid analysis of air samples containing highly complex mixtures of volatilizable biogenic organic compounds (VBOCs). VBOC analytical methodologies are briefly reviewed, and optimal conditions are discussed for sampling with both adsorption/thermal desorption (ATD) cartridges and solid-phase microextraction (SPME) fibers. Air samples containing VBOC emissions from leaves of two tree species (Cedrus atlantica and Calycolpus moritzianus) were obtained by both ATD and SPME. The optimized gas chromatographic conditions utilized a 45 m, 0.25 mm I.D. low-polarity primary column (DB-VRX, 1.4 μm film) and a 1.5 m, 0.25 mm I.D. polar secondary column (StabilwaxTM, 0.25 μm film). Excellent separation was achieved in a 36 min temperature programmed GC × GC chromatogram. Thousands of VBOC peaks were present in the sample chromatograms; hundreds of tentative identifications by NIST mass spectral matching are provided. Very few of the tentatively identified compounds are currently available as authentic standards. Minimum detection limit values for a 5 l ATD sample were 3.5 pptv (10 ng m-3) for isoprene, methyl vinyl ketone, and methacrolein, and ~1.5 pptv (~10 ng m-3) for monoterpenes and sesquiterpenes. Kovats-type chromatographic retention index values on the primary column and relative retention time values on the secondary column are provided for 21 standard compounds and for 417 tentatively identified VBOCs. 19 of the 21 authentic standard compounds were found in one of the Cedrus atlantica SPME samples. In addition, easily quantifiable levels of at least 13 sesquiterpenes were found in an ATD sample obtained from a branch enclosure of Calycolpus moritzianus. Overall, the results obtained via GC × GC-TOFMS highlight an extreme, and largely uncharacterized diversity of VBOCs, consistent with the hypothesis that sesquiterpenes and other compounds

  4. Determination of solute descriptors by chromatographic methods

    International Nuclear Information System (INIS)

    Poole, Colin F.; Atapattu, Sanka N.; Poole, Salwa K.; Bell, Andrea K.

    2009-01-01

    The solvation parameter model is now well established as a useful tool for obtaining quantitative structure-property relationships for chemical, biomedical and environmental processes. The model correlates a free-energy related property of a system to six free-energy derived descriptors describing molecular properties. These molecular descriptors are defined as L (gas-liquid partition coefficient on hexadecane at 298 K), V (McGowan's characteristic volume), E (excess molar refraction), S (dipolarity/polarizability), A (hydrogen-bond acidity), and B (hydrogen-bond basicity). McGowan's characteristic volume is trivially calculated from structure and the excess molar refraction can be calculated for liquids from their refractive index and easily estimated for solids. The remaining four descriptors are derived by experiment using (largely) two-phase partitioning, chromatography, and solubility measurements. In this article, the use of gas chromatography, reversed-phase liquid chromatography, micellar electrokinetic chromatography, and two-phase partitioning for determining solute descriptors is described. A large database of experimental retention factors and partition coefficients is constructed after first applying selection tools to remove unreliable experimental values and an optimized collection of varied compounds with descriptor values suitable for calibrating chromatographic systems is presented. These optimized descriptors are demonstrated to be robust and more suitable than other groups of descriptors characterizing the separation properties of chromatographic systems.

  5. Determination of solute descriptors by chromatographic methods.

    Science.gov (United States)

    Poole, Colin F; Atapattu, Sanka N; Poole, Salwa K; Bell, Andrea K

    2009-10-12

    The solvation parameter model is now well established as a useful tool for obtaining quantitative structure-property relationships for chemical, biomedical and environmental processes. The model correlates a free-energy related property of a system to six free-energy derived descriptors describing molecular properties. These molecular descriptors are defined as L (gas-liquid partition coefficient on hexadecane at 298K), V (McGowan's characteristic volume), E (excess molar refraction), S (dipolarity/polarizability), A (hydrogen-bond acidity), and B (hydrogen-bond basicity). McGowan's characteristic volume is trivially calculated from structure and the excess molar refraction can be calculated for liquids from their refractive index and easily estimated for solids. The remaining four descriptors are derived by experiment using (largely) two-phase partitioning, chromatography, and solubility measurements. In this article, the use of gas chromatography, reversed-phase liquid chromatography, micellar electrokinetic chromatography, and two-phase partitioning for determining solute descriptors is described. A large database of experimental retention factors and partition coefficients is constructed after first applying selection tools to remove unreliable experimental values and an optimized collection of varied compounds with descriptor values suitable for calibrating chromatographic systems is presented. These optimized descriptors are demonstrated to be robust and more suitable than other groups of descriptors characterizing the separation properties of chromatographic systems.

  6. Effects of Gas Dynamics on Rapidly Collapsing Bubbles

    OpenAIRE

    Bauman, Spenser; Fomitchev-Zamilov, Max

    2013-01-01

    The dynamics of rapidly collapsing bubbles are of great interest due to the high degree of energy focusing that occurs withing the bubble. Molecular dynamics provides a way to model the interior of the bubble and couple the gas dynamics with the equations governing the bubble wall. While much theoretical work has been done to understand how a bubble will respond to an external force, the internal dynamics of the gas system are usually simplified greatly in such treatments. This paper shows ho...

  7. Decomposition of pilocarpine eye drops assessed by a highly efficient high pressure liquid chromatographic method

    NARCIS (Netherlands)

    Kuks, P. F.; Weekers, L. E.; Goldhoorn, P. B.

    1990-01-01

    A rapid high-resolution high pressure liquid chromatographic method was developed for assaying pilocarpine. Pilocarpine in ophthalmic solutions decomposes fairly rapidly to give isopilocarpine, pilocarpic acid and isopilocarpic acid. The quality of an ophthalmic solution can be assessed by assaying

  8. Gas chromatographic determination with electron capture detection of residual ethylene oxide in intraocular lenses

    Energy Technology Data Exchange (ETDEWEB)

    Kikuchi, H.; Nakamura, A.; Tsuji, K.

    1988-01-01

    A sensitive method is described to determine trace quantities of ethylene oxide (EO) in EO-sterilized intraocular lenses (IOLs). An IOL is dipped in ethanol containing 0.25 ppm propylene oxide (PO) in a 4 mL vial, 2 drops of freshly distilled hydrobromic acid is added through a septum, and the mixture is warmed at 50/sup 0/C for 24 h. It is then neutralized by vigorous shaking with sodium bicarbonate, dehydrated with anhydrous sodium sulfate, and filtered. The filtrate is injected into a gas chromatograph with electron-capture detection, and the peak height ratio of ethylene bromohydrin/propylene bromohydrin is measured. EO residue is calculated from the calibration curve obtained through a similar procedure with the standard EO/PO solutions. The limit of determination is 0.04 ..mu..g/lens (ca 2.0 ppm). When EO residue levels were determined for IOLs sampled at 3 different aeration periods after stabilization, the authors found that 9 days of aeration was necessary to meet the US Food and Drug Administration proposed limit for EO residue in IOLs.

  9. Direct chromatographic methods for the rapid determination of homogentisic acid in strawberry tree (Arbutus unedo L.) honey.

    Science.gov (United States)

    Scanu, Roberta; Spano, Nadia; Panzanelli, Angelo; Pilo, Maria I; Piu, Paola C; Sanna, Gavino; Tapparo, Andrea

    2005-10-07

    Two rapid and direct chromatographic methods based on reverse phase-high performance liquid chromatography (RP-HPLC) and ion chromatography (IC) were developed for the determination of homogentisic acid (HA) in honey. This is the marker of the botanic origin of strawberry tree honey. The methods were validated and tested using 22 samples from Sardinia, Italy. The IC method is faster than the RP-HPLC one (6 min versus 13 min of total run), but it is slightly less sensitive (the limit of detection (LOD), is 26 mg kg(-1) versus 15 mg kg(-1)) and reproducible (relative standard deviation, RSD, of 10.4 and 4.4%, respectively). The whole dataset of validation parameters allows both the proposed methods to be considered as bias-free (by recovery tests, comparison of analytical results of the two independent methods and analysis of a synthetic sample) and precise (both the techniques show a repeatability better than 2% repeatability in the range between 70 and 600 mg kg(-1)).

  10. Rapid ion-pair liquid chromatographic method for the determination of fenbendazole marker residue in fermented dairy products.

    Science.gov (United States)

    Vousdouka, Venetia I; Papapanagiotou, Elias P; Angelidis, Apostolos S; Fletouris, Dimitrios J

    2017-04-15

    A simple, rapid and sensitive liquid chromatographic method that allows for the quantitative determination of fenbendazole residues in fermented dairy products is described. Samples were extracted with a mixture of acetonitrile-phosphoric acid and the extracts were defatted with hexane to be further partitioned into ethyl acetate. The organic layer was evaporated to dryness and the residue was reconstituted in mobile phase. Separation of fenbendazole and its sulphoxide, sulphone, and p-hydroxylated metabolites was carried out isocratically with a mobile phase containing both positively and negatively charged pairing ions. Overall recoveries ranged from 79.8 to 88.8%, while precision data, based on within and between days variations, suggested an overall relative standard deviation of 6.3-11.0%. The detection and quantification limits were lower than 9 and 21μg/kg, respectively. The method has been successfully applied to quantitate fenbendazole residues in Feta cheese and yoghurt made from spiked and incurred ovine milk. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. High Performance Liquid Chromatographic Method for Determination of Dipyridamole in Human Plasma

    Directory of Open Access Journals (Sweden)

    DAVOOD BEIGI BAND ARAB ADI

    1999-08-01

    Full Text Available A simple, rapid and specific high-performance liquid chromatographic procedure is reported for"nquantitative determination of dipyridamole in human -plasma. The assay uses a reversed-phase"nhigh-performance liquid chromatographic (HPLC and UV detection at 280nm and has a limit"nof detection of approximately 5ng/mL. The mobile phase consists of MeOH-H20 (60:40"nadjusted to pH 3.3. Dipyridamole was extracted from plasma by back-extraction procedure, with"npropranolol as the internal standard. The reproducibility of the method is satisfactory

  12. Gas chromatographic-mass spectrometric determination of hydrophilic compounds in environmental water by solid-phase extraction with activated carbon fiber felt.

    Science.gov (United States)

    Kawata, K; Ibaraki, T; Tanabe, A; Yagoh, H; Shinoda, A; Suzuki, H; Yasuhara, A

    2001-03-09

    Simple gas chromatographic-mass spectrometric determination of hydrophilic organic compounds in environmental water was developed. A cartridge containing activated carbon fiber felt was made by way of trial and was evaluated for solid-phase extraction of the compounds in water. The hydrophilic compounds investigated were acrylamide, N,N-dimethylacetamide, N,N-dimethylformamide, 1,4-dioxane, furfural, furfuryl alcohol, N-nitrosodiethylamine and N-nitrosodimethylamine. Overall recoveries were good (80-100%) from groundwater and river water. The relative standard deviations ranged from 4.5 to 16% for the target compounds. The minimum detectable concentrations were 0.02 to 0.03 microg/l. This method was successfully applied to several river water samples.

  13. Chromatographic analysis of methylglyoxal and other α-dicarbonyls using gas-diffusion microextraction.

    Science.gov (United States)

    Santos, Christiane M; Valente, Inês M; Gonçalves, Luís M; Rodrigues, José A

    2013-12-07

    Many α-dicarbonyl compounds such as methylglyoxal, diacetyl and pentane-2,3-dione are important quality markers of processed foods. They are produced by enzymatic and chemical processes, the Maillard reaction is the most known chemical route for α-dicarbonyl formation. In the case of methylglyoxal, there are obstacles to be overcome when analysing this compound due to its high reactivity, low volatility and low concentration. The use of extraction techniques based on the volatilization of methylglyoxal (like solid-phase microextraction) showed to be ineffective for the methylglyoxal extraction from aqueous solutions. Therefore, derivatization is typically applied to increase analyte's volatility. In this work a new methodology for the extraction and analysis of methylglyoxal and also diacetyl and pentane-2,3-dione from selected food matrices is presented. It is based on a gas-diffusion microextraction step followed by high performance liquid chromatographic analysis. It was successfully applied to port wines, black tea and soy sauce. Methylglyoxal, diacetyl and pentane-2,3-dione were quantified in the following concentration ranges: 0.24-1.74 mg L(-1), 0.1-1.85 mg L(-1) and 0.023-0.15 mg L(-1), respectively. The main advantages over existing methodologies are its simplicity in terms of sample handling, not requiring any chemical modification of the α-dicarbonyls prior to the extraction, low reagent consumption and short time of analysis.

  14. Gas chromatographic isolation of individual compounds from complex matrices for radiocarbon dating.

    Science.gov (United States)

    Eglinton, T I; Aluwihare, L I; Bauer, J E; Druffel, E R; McNichol, A P

    1996-03-01

    This paper describes the application of a novel, practical approach for isolation of individual compounds from complex organic matrices for natural abundance radiocarbon measurement. This is achieved through the use of automated preparative capillary gas chromatography (PCGC) to separate and recover sufficient quantities of individual target compounds for (14)C analysis by accelerator mass spectrometry (AMS). We developed and tested this approach using a suite of samples (plant lipids, petroleums) whose ages spanned the (14)C time scale and which contained a variety of compound types (fatty acids, sterols, hydrocarbons). Comparison of individual compound and bulk radiocarbon signatures for the isotopically homogeneous samples studied revealed that Δ(14)C values generally agreed well (±10%). Background contamination was assessed at each stage of the isolation procedure, and incomplete solvent removal prior to combustion was the only significant source of additional carbon. Isotope fractionation was addressed through compound-specific stable carbon isotopic analyses. Fractionation of isotopes during isolation of individual compounds was minimal (radiocarbon measurements. The addition of carbon accompanying derivatization of functionalized compounds (e.g., fatty acids and sterols) prior to chromatographic separation represents a further source of potential error. This contribution can be removed using a simple isotopic mass balance approach. Based on these preliminary results, the PCGC-based approach holds promise for accurately determining (14)C ages on compounds specific to a given source within complex, heterogeneous samples.

  15. Comparison of chromatographic methods for the determination of bound glycerol in biodiesel

    Energy Technology Data Exchange (ETDEWEB)

    Foglia, T.A.; Jones, K.C.; Nunez, A.; Phillips, J.G. [U.S. Dept. of Agriculture, Agricultural Research Service, Eastern Regional Research Center, Wyndmoor, PA (United States); Mittelbach, M. [Inst. for Chemistry, Univ. of Graz, Graz (Austria)

    2004-09-01

    An important fuel criterion for biodiesel is bound glycerol, which is a function of the residual amount of triglycerides and partial glycerides in the biodiesel. Either high-temperature gas chromatography or high performance liquid chromatography can be used for determining these minor but important components in biodiesel. In this paper we have conducted a statistical study on the accuracy of the two methods for ascertaining the bound glycerol in biodiesel fuels obtained from different feedstocks. Analysis of variance showed that with one exception, namely diacylglycerols in some soy oil based biodiesel, there was no statistical difference in bound glycerol for the biodiesel samples analyzed or a difference between methods. Operationally, the high performance liquid chromatographic method is superior to the high temperature gas chromatographic method in that it requires no sample derivatization, has shorter analysis times, and is directly applicable to most biodiesel fuels. (orig.)

  16. Pyrolysis-gas chromatographic method for kerogen typing

    Energy Technology Data Exchange (ETDEWEB)

    Larter, S.R.; Douglas, A.G.

    1980-01-01

    The classification of kerogens according to their type and rank is important for the definition of any kerogen assemblage. Whereas optical methods of rank determination are well known, vitrinite reflectance and spore coloration being the most widely accepted chemical methods for typing kerogens are less developed. In this work we show that pyrograms, produced by pyrolyzing microgram quantities of solvent-extracted kerogens, enable not only their characterization in terms of a chromatographic fingerprint but also the production of a numerical type index determined as the ratio of m(+p)-xylene/n-octene (oct-1-ene) in the pyrogram. This index appears to be a close function of kerogen type. Type 3 kerogens (Tissot et al., 1974), including vitrinite, provide a high type index and have pyrolysates dominated by aromatic and phenolic compounds whereas type 1 kerogens provide an aliphatic-rich pyrolysate and consequently a low type index. The type index described here correlates well with microscopic and elemental analysis data and the pyrogram fingerprint provides an additional level of characterization not attainable with other current typing techniques.

  17. Derivatization reactions in the gas—liquid chromatographic analysis of drugs in biological fluids

    NARCIS (Netherlands)

    Hulshoff, A.; Lingeman, H.

    1984-01-01

    Alkylation, acylation, silylation and other derivatization reactions applied to the gas chromatographic analysis of drugs in biological matrices are reviewed. Reaction conditions are discussed in relation to reaction mechanisms. Detector-oriented labelling of drugs, and derivatization with chiral

  18. Microfabricated Gas Phase Chemical Analysis Systems

    International Nuclear Information System (INIS)

    FRYE-MASON, GREGORY CHARLES; HELLER, EDWIN J.; HIETALA, VINCENT M.; KOTTENSTETTE, RICHARD; LEWIS, PATRICK R.; MANGINELL, RONALD P.; MATZKE, CAROLYN M.; WONG, CHUNGNIN C.

    1999-01-01

    A portable, autonomous, hand-held chemical laboratory ((micro)ChemLab(trademark)) is being developed for trace detection (ppb) of chemical warfare (CW) agents and explosives in real-world environments containing high concentrations of interfering compounds. Microfabrication is utilized to provide miniature, low-power components that are characterized by rapid, sensitive and selective response. Sensitivity and selectivity are enhanced using two parallel analysis channels, each containing the sequential connection of a front-end sample collector/concentrator, a gas chromatographic (GC) separator, and a surface acoustic wave (SAW) detector. Component design and fabrication and system performance are described

  19. A pyrolysis/gas chromatographic method for the determination of hydrogen in solid samples

    Science.gov (United States)

    Carr, R. H.; Bustin, R.; Gibson, E. K.

    1987-01-01

    A method is described for the determination of hydrogen in solid samples. The sample is heated under vacuum after which the evolved gases are separated by gas chromatography with a helium ionization detector. The system is calibrated by injecting known amounts of hydrogen, as determined manometrically. The method, which is rapid and reliable, was checked for a variety of lunar soils; the limit of detection is about 10 ng of hydrogen.

  20. Chiral ionic liquids in chromatographic and electrophoretic separations.

    Science.gov (United States)

    Kapnissi-Christodoulou, Constantina P; Stavrou, Ioannis J; Mavroudi, Maria C

    2014-10-10

    This report provides an overview of the application of chiral ionic liquids (CILs) in separation technology, and particularly in capillary electrophoresis and both gas and liquid chromatography. There is a large number of CILs that have been synthesized and designed as chiral agents. However, only a few have successfully been applied in separation technology. Even though this application of CILs is still in its early stages, the scientific interest is increasing dramatically. This article is focused on the use of CILs as chiral selectors, background electrolyte additives, chiral ligands and chiral stationary phases in electrophoretic and chromatographic techniques. Different examples of CILs, which contain either a chiral cation, a chiral anion or both, are presented in this review article, and their major advantages along with their potential applications in chiral electrophoretic and chromatographic recognition are discussed. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Determination of insecticides malathion and lambda-cyhalothrin residues in zucchini by gas chromatography

    Directory of Open Access Journals (Sweden)

    Hayam M. Lofty

    2013-12-01

    Full Text Available A sensitive gas chromatographic method has been developed for the determination of malathion and lambda-cyhalothrin (λ-cyhalothrin insecticide residues in zucchini. The developed method consists of extraction with acetone, purification and partitioning with methylene chloride, column chromatographic clean-up, and finally capillary gas chromatographic determination of the insecticides. The recoveries of method were greater than 90% and limit of determination was 0.001 ppm for both insecticides. The method was applied to determine residues and the rate of disappearance of malathion and λ-cyhalothrin from fruits of zucchini (open field treatment, 50 cc of Malason/Cormandel 57% EC (emulsifiable concentrate for 100 L of water, 20 cc of LAMBDA SUPER FOG 5% liquid for 100 L of water. The insecticide incorporated into the plants decreased rapidly with a half-life time around 0.77 day (18.5h for malathion and 4 days for λ-cyhalothrin. It is not recommended to use zucchini before 12 h of malathion application. For λ-cyhalothrin, the preharvest interval is 5 days. Four market samples were chosen from different regions from A.R.E. and all of them showed no residues of malathion or λ-cyhalothrin.

  2. Arsenic speciation in sulfidic waters: reconciling contradictory spectroscopic and chromatographic evidence.

    Science.gov (United States)

    Planer-Friedrich, Britta; Suess, Elke; Scheinost, Andreas C; Wallschläger, Dirk

    2010-12-15

    In recent years, analytical methods have been developed that have demonstrated that soluble arsenic-sulfur species constitute a major fraction of dissolved arsenic in sulfidic waters. However, an intense debate is going on about the exact chemical nature of these compounds, since X-ray absorption spectroscopy (XAS) data generated at higher (mmol/L) concentrations suggest the presence of (oxy)thioarsenites in such waters, while ion chromatographic (IC) and mass spectroscopic data at lower (μmol/L to nmol/L) concentrations indicate the presence of (oxy)thioarsenates. In this contribution, we connect and explain these two apparently different types of results. We show by XAS that thioarsenites are the primary reaction products of arsenite and sulfide in geochemical model experiments in the complete absence of oxygen. However, thioarsenites are extremely unstable toward oxidation, and convert rapidly into thioarsenates when exposed to atmospheric oxygen, e.g., while waiting for analysis on the chromatographic autosampler. This problem can only be eliminated when the entire chromatographic process is conducted inside a glovebox. We also show that thioarsenites are unstable toward sample dilution, which is commonly employed prior to chromatographic analysis when ultrasensitive detectors like ICP-MS are used. This instability has two main reasons: if pH changes during dilution, then equilibria between individual arsenic-sulfur species rearrange rapidly due to their different stability regions within the pH range, and if pH is kept constant during dilution, then this changes the ratio between OH(-) and SH(-) in solution, which in turn shifts the underlying speciation equilibria. This problem is avoided by analyzing samples undiluted. Our studies show that thioarsenites appear as thioarsenates in IC analyses if oxygen is not excluded completely, and as arsenite if samples are diluted in alkaline anoxic medium. This also points out that thioarsenites are necessary

  3. A rapid hydrophilic interaction liquid chromatographic determination of glimepiride in pharmaceutical formulations

    Directory of Open Access Journals (Sweden)

    Si Zhou

    2017-09-01

    Full Text Available Glimepiride is one of the most widely prescribed antidiabetic drugs and contains both hydrophobic and hydrophilic functional groups in its molecules, and thus could be analyzed by either reversed-phase high performance liquid chromatography (HPLC or hydrophilic interaction liquid chromatography (HILIC. In the literature, however, only reversed-phase HPLC has been reported. In this study, a simple, rapid and accurate hydrophilic interaction liquid chromatographic method was developed for the determination of glimepiride in pharmaceutical formulations. The analytical method comprised a fast ultrasound-assisted extraction with acetonitrile as a solvent followed by HILIC separation and quantification using a Waters Spherisorb S5NH2 hydrophilic column with a mobile phase consisting of acetonitrile and aqueous acetate buffer (5.0 mM. The retention time of glimepiride increased slightly with decrease of mobile phase pH value from 6.8 to 5.8 and of acetonitrile content from 60% to 40%, indicating that both hydrophilic, ionic, and hydrophobic interactions were involved in the HILIC retention and elution mechanisms. Quantitation was carried out with a mobile phase of 40% acetonitrile and 60% aqueous acetate buffer (5.0 mM at pH 6.3, by relating the peak area of glimepiride to that of the internal standard, with a detection limit of 15.0 μg/L. UV light absorption responses at 228 nm were linear over a wide concentration range from 50.0 μg/L to 6.00 mg/L. The recoveries of the standard added to pharmaceutical tablet samples were 99.4–103.0% for glimepiride, and the relative standard deviation for the analyte was less than 1.0%. This method has been successfully applied to determine the glimepiride contents in pharmaceutical formulations.

  4. Gas analysis during the chemical vapor deposition of carbon

    International Nuclear Information System (INIS)

    Lieberman, M.L.; Noles, G.T.

    1973-01-01

    Gas chromatographic analyses were performed during the chemical vapor deposition of carbon in both isothermal and thermal gradient systems. Such data offer insight into the gas phase processes which occur during deposition and the interrelations which exist between gas composition, deposition rate, and resultant structure of the deposit. The results support a carbon CVD model presented previously. The application of chromatographic analysis to research, development, and full-scale facilities is shown. (U.S.)

  5. Chromatographic retention and structure roofing tile effect of isomers and its fine structure

    NARCIS (Netherlands)

    Walraven, J.J.; Ladon, A.W.; Keulemans, A.I.M.

    1968-01-01

    Logarithmic plots of gas chromatographic retention data for different classes of compds. on different pairs of stationary phases were constructed. A remarkable effect was found. Isomers are spread along parallel lines in a repeated pattern, forming a \\"roofing-tile\\" series. The scattering of points

  6. Gas chromatographic studies of the relative retention of the sulfur isotopes in carbonyl sulfide, carbon disulfide, and sulfur dioxide

    International Nuclear Information System (INIS)

    Fetzer, J.C.; Rogers, L.B.

    1980-01-01

    A precision gas chromatograph, coupled to a quadrupole mass spectrometer and an on-line computer, was used to study the fractionation on Porasil A of the 32 S/ 34 S isotopic pair in a variety of sulfur-containing molecules. Carbonyl sulfide (COS) yielded an average α value of 1.00074 +- 0.00017 (standard deviation) for the temperature range 25 0 C to 75 0 C. The carbon disulfide (CS 2 ) value was 1.00069 +- 0.00023 for the range 53 0 C to 103 0 C, and that for sulfur dioxide (SO 2 ) was 1.00090 +- 0.00018 for the range 62 0 C to 112 0 C. Differential thermodynamic data have been reported. A Porapak Q column showed no fractionation of this isotopic pair in these three molecules

  7. [The elaboration of gas chromatographic method of the determination of N-nitrosamines (N-nitrosodimethylamine, N-nitrosodiethylamine) in biological samples (urine)].

    Science.gov (United States)

    Zaytseva, N V; Ulanova, T S; Nurislamova, T V; Popova, N A

    2014-01-01

    The issues of the elaboration of a method for the determination of N-nitrosamines (N-nitrosodimethylamine, N-nitrosodiethylamine) in urine by means of the method of capillary gas chromatography with the use of a thermionic detector are considered. There were performed investigations on the study of the efficacy of the extraction of N-nitrosamines from the urine by steam distillation and gas chromatographic detection of headspace. With the aim of the maximal recovery of N-nitrosamines from the urine and setting parameters of the extraction two method were used to prepare the bioassay for the analysis the alkalization with potassium hydroxide and the addition of salting out reagent--neutral salts of alkali and alkaline earth metals. During the process of performed studies there was found that the greatest degree of extraction of N-nitrosamines from the urine by the method of headspace analysis is achieved if using the salting-out agent in an amount of 16 g of sodium sulfate and for N-nitrosodimethylamine is 99%, for N-nitrosodiethylamine--100%.

  8. Rapid identification and quantification of methamphetamine and amphetamine in hair by gas chromatography/mass spectrometry coupled with micropulverized extraction, aqueous acetylation and microextraction by packed sorbent.

    Science.gov (United States)

    Miyaguchi, Hajime; Iwata, Yuko T; Kanamori, Tatsuyuki; Tsujikawa, Kenji; Kuwayama, Kenji; Inoue, Hiroyuki

    2009-05-01

    We developed a rapid identification and quantification method for the toxicological analysis of methamphetamine and amphetamine in human hair by gas chromatography/mass spectrometry coupled with a novel combination of micropulverized extraction, aqueous acetylation and microextraction by packed sorbent (MEPS) named MiAMi-GC/MS. A washed hair sample (1-5 mg) was micropulverized for 5 min in a 2 mL plastic tube with 250 microL of water. An anion-exchange sorbent was added to adsorb anionic interferences. After removing the residue with a membrane-filter unit, sodium carbonate and acetic anhydride was admixed in turn. Acetylation was completed in approximately 20 min at room temperature. The acetylated analytes in the reaction liquid were concentrated to an octadecylsilica sorbent packed in the needle of a syringe by a CombiPAL autosampler. Elution was carried out with 50 microL of methanol, and the entire eluate injected into a gas chromatograph using a programmable temperature vaporizing (PTV) technique. The time required for sample preparation and GC/MS analysis was approximately 1 h from a washed hair sample, and an evaporation process was not required. Ranges for quantification were 0.20-50 (ng/mg) each for methamphetamine and amphetamine using 1 mg of hair. Accuracy and relative standard deviation (RSD) were evaluated intraday and interday at three concentrations, and the results were within the limit of a guidance issued by U.S. Food and Drug Administration. For identification, full-scan mass spectra of methamphetamine and amphetamine were obtained using 5 mg of fortified hair samples at 0.2 ng/mg. The extraction device of MEPS was durable for at least 300 extractions, whereas the liner of the gas chromatograph should be replaced after 20-30 times use. The carry over was estimated to be about 1-2%. This sample-preparation method coupled with GC/MS is fast and labor-saving in comparison with conventional methods.

  9. Gas supply from WCSB -- Matured more rapidly than expected

    International Nuclear Information System (INIS)

    Hawkins, D. J.

    2003-01-01

    A 2002 National Energy Board report forecast a decline in short-term gas deliverability from the Western Canadian Sedimentary Basin (WCSB) through 2004. However, this report contradicts a 1999 report which forecast a robust supply of natural gas through 2010. To obtain some clarity about the situation, this article undertakes an assessment of the information on gas supply in Alberta during the second half of the 1990s, in an attempt to account for the dramatic shift in outlook for gas supply in the WCSB by 2002. After a thorough examination of natural gas activities in the Basin during the 1990s, the author concludes that gas production in the WCSB has matured more rapidly than expected; moreover, there were clear indications that this might occur as early as the mid-1990s. Further curtailment in Alberta gas production might be expected as the debate on gas production in the Athabasca area heats up. The result of the assessment is that new resources of gas such as coal-bed methane and natural gas deposits in northeast British Columbia may come on stream, but governments will be challenged to provide incentives for sustaining gas pipeline activity in the WCSB. In the longer term there is potential for a gas pipeline from Alaska, but there is still much uncertainty about the route, line size, operating pressure, utilization of downstream pipelines and ultimate timing. In Canada, there is considerable support for a gas pipeline in the Mackenzie Valley, and plans for development are well advanced. 9 refs., 7 figs

  10. Determination of insecticides malathion and lambda-cyhalothrin residues in zucchini by gas chromatography

    OpenAIRE

    Lofty, Hayam M.; Abd El-Aleem, Abd El-Aziz A.; Monir, Hany H.

    2013-01-01

    A sensitive gas chromatographic method has been developed for the determination of malathion and lambda-cyhalothrin (λ-cyhalothrin) insecticide residues in zucchini. The developed method consists of extraction with acetone, purification and partitioning with methylene chloride, column chromatographic clean-up, and finally capillary gas chromatographic determination of the insecticides. The recoveries of method were greater than 90% and limit of determination was 0.001 ppm for both insecticide...

  11. Rapid determination of environmental plutonium in large water samples by means of manganese dioxide Co-precipitation and extraction chromatographic separation

    International Nuclear Information System (INIS)

    Sidhu, R.S.; Hoff, P.

    1999-01-01

    Plutonium activity determinations in environmental water samples are routinely performed in many laboratories. Due to the low plutonium concentrations and the complexity of the plutonium aqueous chemistry, these analysis involve cumbersome preconcentration and separation procedures and long measurement times. We describe a procedure where MnO 2 (s) is used as scavenger to preconcentrate Pu prior to separation by the transuranium specific extraction chromatographic resin TRU-Resin. The ability of MnO 4 - /MnO 2 (s) to destroy organic matter and oxidise plutonium is combined with the specific behaviour of the TRU-resin for transuranium elements. The method facilitates a rapid preconcentration and separation of plutonium. With the use of this procedure, the laboratory work on one sample can be performed in one day with minimum attention. The overall yields from a 200 litre fresh- or seawater sample to a measurable Pu source are between 70-85%. (orig.)

  12. Miniaturized Planar Room Temperature Ionic Liquid Electrochemical Gas Sensor for Rapid Multiple Gas Pollutants Monitoring.

    Science.gov (United States)

    Wan, Hao; Yin, Heyu; Lin, Lu; Zeng, Xiangqun; Mason, Andrew J

    2018-02-01

    The growing impact of airborne pollutants and explosive gases on human health and occupational safety has escalated the demand of sensors to monitor hazardous gases. This paper presents a new miniaturized planar electrochemical gas sensor for rapid measurement of multiple gaseous hazards. The gas sensor features a porous polytetrafluoroethylene substrate that enables fast gas diffusion and room temperature ionic liquid as the electrolyte. Metal sputtering was utilized for platinum electrodes fabrication to enhance adhesion between the electrodes and the substrate. Together with carefully selected electrochemical methods, the miniaturized gas sensor is capable of measuring multiple gases including oxygen, methane, ozone and sulfur dioxide that are important to human health and safety. Compared to its manually-assembled Clark-cell predecessor, this sensor provides better sensitivity, linearity and repeatability, as validated for oxygen monitoring. With solid performance, fast response and miniaturized size, this sensor is promising for deployment in wearable devices for real-time point-of-exposure gas pollutant monitoring.

  13. Infrared spectrophotometry, a rapid and effective tool for characterization of direct distillation naphthas

    International Nuclear Information System (INIS)

    Baldrich Ferrer, Carlos A; Novoa Mantilla, Luz Angela

    2005-01-01

    The characterization of naphtha obtained by direct distillation of medium and heavy crude oils is often limited by the low yield of these fractions. Gas chromatography is a technique that allows a complete determination of the chemical composition of this fraction. However, the prediction of properties such as octane rating and RVP from chromatographic data is a difficult task because there are not adequate models to predict the interaction of the different components, and particularly in the case of heavier fractions, there are some problems for the complete separation of components under the gas chromatographic conditions. The IR technology constitutes a rapid and effective tool to predict several properties of naphtha from the correlation of the spectrum in the infrared area and the properties. In this study, prediction models were developed in a Petrospec Cetane 2000 analyzer, in order to predict in a fast and simple way, the density, the antiknock index and the aromatic content of straight run naphtha obtained in a standard crude oil distillation unit. The equipment used was designed in the factory for the exclusive characterization of medium distillation and not for lighter fractions therefore this work constitutes an innovation given the extensive applications of this type of analyzers

  14. Chromatographic, Spectroscopic and Mass Spectrometric Approaches for Exploring the Habitability of Mars in 2012 and Beyond with the Curiosity Rover

    Science.gov (United States)

    Mahaffy, Paul

    2012-01-01

    The Sample Analysis at Mars (SAM) suite of instruments on the Curiosity Rover of Mars Science Laboratory Mission is designed to provide chemical and isotopic analysis of organic and inorganic volatiles for both atmospheric and solid samples. The goals of the science investigation enabled by the gas chromatograph mass spectrometer and tunable laser spectrometer instruments of SAM are to work together with the other MSL investigations is to quantitatively assess habitability through a series of chemical and geological measurements. We describe the multi-column gas chromatograph system employed on SAM and the approach to extraction and analysis of organic compounds that might be preserved in ancient martian rocks.

  15. Modeling Aquatic Toxicity through Chromatographic Systems.

    Science.gov (United States)

    Fernández-Pumarega, Alejandro; Amézqueta, Susana; Farré, Sandra; Muñoz-Pascual, Laura; Abraham, Michael H; Fuguet, Elisabet; Rosés, Martí

    2017-08-01

    Environmental risk assessment requires information about the toxicity of the growing number of chemical products coming from different origins that can contaminate water and become toxicants to aquatic species or other living beings via the trophic chain. Direct toxicity measurements using sensitive aquatic species can be carried out but they may become expensive and ethically questionable. Literature refers to the use of chromatographic measurements that correlate to the toxic effect of a compound over a specific aquatic species as an alternative to get toxicity information. In this work, we have studied the similarity in the response of the toxicity to different species and we have selected eight representative aquatic species (including tadpoles, fish, water fleas, protozoan, and bacteria) with known nonspecific toxicity to chemical substances. Next, we have selected four chromatographic systems offering good perspectives for surrogation of the eight selected aquatic systems, and thus prediction of toxicity from the chromatographic measurement. Then toxicity has been correlated to the chromatographic retention factor. Satisfactory correlation results have been obtained to emulate toxicity in five of the selected aquatic species through some of the chromatographic systems. Other aquatic species with similar characteristics to these five representative ones could also be emulated by using the same chromatographic systems. The final aim of this study is to model chemical products toxicity to aquatic species by means of chromatographic systems to reduce in vivo testing.

  16. A modified commercial gas chromatograph for the continuous monitoring of the thermal degradation of sunflower oil and off-line solid phase extraction gas-chromatography-mass spectrometry characterization of released volatiles.

    Science.gov (United States)

    Ontañon, I; Sanz, J; Escudero, A; de Marcos, S; Ferreira, V; Galbán, J

    2015-04-03

    A homemade flow cell attached to a commercial Gas Chromatograph equipped with a Flame Ionization Detector (FID) has been designed for the continuous monitoring of volatile compounds released during heating edible oils. Analytical parameters such as mass of sample, temperature and flow rates have been optimized and the obtained results have been compared with the corresponding thermographs from standard TG systems. Results show that under optimum conditions, the profiles of volatiles released upon heating are comparable to the profiles of TG curves, suggesting that the FID based system could be an alternative to TGA. Additionally, volatiles have been retained in a Lichrolut EN(®) resin, eluted and analyzed by Gas Chromatography-Mass Spectrometry. In this case, forty five compounds have been identified (acids, alcohols, alkanes, aldehydes, ketones and furans) and compared with the FID signals, working both in air or nitrogen atmosphere. It has been concluded that the oxidative thermal degradation is prevented in the presence of a nitrogen atmosphere. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Fiber-optic sensors for rapid, inexpensive characterization of soil and ground water contamination

    International Nuclear Information System (INIS)

    Milanovich, F.P.; Yow, J.L. Jr.

    1994-08-01

    The extent and complexity of worldwide environmental contamination are great enough that characterization, remediation, and performance monitoring will be extremely costly and lengthy. Characterization techniques that are rapid, inexpensive, and simple and that do not generate waste are urgently needed. Towards this end LLNL is developing a fiber-optic chemical sensor technology for use in groundwater and vadose-zone monitoring. We use a colorimetric detection technique, based on an irreversible chemical reaction between a specific reagent and the target compound. The accuracy and sensitivity of the sensor (<5 ppb by weight in water, determined by comparison with gas chromatographic standard measurements) are sufficient for environmental monitoring of trichloroethylene (TCE) and chloroform

  18. Chromatographic analysis and purification of multiply tritium-labelled eicosanoids

    International Nuclear Information System (INIS)

    Shevchenko, V.P.; Nagaev, I.Yu.; Myasoedov, N.F.

    1988-01-01

    A comparative study of different chromatographic techniques (gas-liquid (GLC), thin-layer (TLC), liquid (LC), high-pressure liquid (HPLC) chromatography) is presented. They were applied to the analysis and preparative purification of tritium-labelled eicosanoids with a molar radioactivity of 1.8-8.8 TBq/mmol, obtained by selective hydrogenation and by chemical or enzymic methods. The possibility of analyzing reaction mixtures and isolating individual multiply labelled eicosanoids with a chemical and radiochemical purity of 95-98% was demonstrated. Special features of HPLC for high molar radioactivity eicosanoids are considered. (author) 9 refs.; 6 tabs

  19. Development of conjugate methods with gas chromatography for inorganic compounds analysis

    International Nuclear Information System (INIS)

    Baccan, N.

    1975-01-01

    The application of gas chromatography combined with mass spectrometry or with nuclear methods for the analysis of inorganic compounds is studied. The advantages of the use of a gas chromatograph coupled with a quadrupole mass spectrometer or with a high resolution radiation detector, are discussed. We also studied the formation and solvent extraction of metal chelates; an aliquot of the organic phase was directly injected into the gas chromatograph and the eluted compounds were detected by mass spectrometry or, when radioactive, by nuclear methods. (author)

  20. Potential for Measurement of Trace Volatile Organic Compounds in Closed Environments Using Gas Chromatograph/Differential Mobility Spectrometer

    Science.gov (United States)

    Limero, Thomas; Cheng, Patti

    2007-01-01

    For nearly 3.5 years, the Volatile Organic Analyzer (VOA) has routinely analyzed the International Space Station (ISS) atmosphere for a target list of approximately 20 volatile organic compounds (VOCs). Additionally, an early prototype of the VOA collected data aboard submarines in two separate trials. Comparison of the data collected on ISS and submarines showed a surprising similarity in the atmospheres of the two environments. Furthermore, in both cases it was demonstrated that the VOA data can detect hardware issues unrelated to crew health. Finally, it was also clear in both operations that the VOA s size and resource consumption were major disadvantages that would restrict its use in the future. The VOA showed the value of measuring VOCs in closed environments, but it had to be shrunk if it was to be considered for future operations in these environments that are characterized by cramped spaces and limited resources. The Sionex Microanalyzer is a fraction of the VOA s size and this instrument seems capable of maintaining or improving upon the analytical performance of the VOA. The two design improvements that led to a smaller, less complex instrument are the Microanalyzer s use of recirculated air as the gas chromatograph s carrier gas and a micromachined detector. Although the VOA s ion mobility spectrometer and the Microanalyzer s differential mobility spectrometer (DMS) are related detector technologies, the DMS was more amenable to micromachining. This paper will present data from the initial assessment of the Microanalyzer. The instrument was challenged with mixtures that simulated the VOCs typically detected in closed-environment atmospheres.

  1. Different reactivities of amphetamines with N-methyl-bis(trifluoroacetamide) in heated gas chromatographic injectors.

    Science.gov (United States)

    Hidvégi, E; Hideg, Zs; Somogyi, G P

    2008-03-01

    A fast gas chromatographic mass spectrometric method has been developed earlier for the determination of amphetamine derivatives in human serum and urine. For derivatization, N-methyl-bis(trifluoroacetamide) (MBTFA) was used. Derivatization was performed using an on-line mode, since 1 microl of MBTFA and 1 microl sample extract, dissolved in toluene were injected simultaneously. In this study, the reactivity of the several amphetamine type analytes with MBTFA was investigated. MBTFA used for flash derivatization was applied undiluted on the one hand and diluted 4--4096-fold with acetonitrile on the other hand. Studying several amphetamines in the test sample spiked at the same concentrations we found that they could be divided into 3 groups based on relative target ion peak areas as a function of MBTFA dilution. Group 1, containing only primary amines showed an early increase of the relative peak areas if we increased MBTFA concentration, where group 2 (mainly N-methyl secondary amines) showed that relative peak areas started to increase intensively at higher MBTFA concentrations. Finally, MDEA as an N-ethyl secondary amine, representing group 3, showed significant increase if only slightly diluted MBTFA was used as a flash reagent. This phenomenon can be explained mainly with the less and less reactivity of amine groups in the case of groups 2 and 3, compared to group 1. These findings could help to optimise analytical methods involving flash derivatization processes.

  2. Coalbed gas desorption in canisters: Consumption of trapped atmospheric oxygen and implications for measured gas quality

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Hui; Schimmelmann, Arndt [Indiana University, Dept. of Geological Sciences, Bloomington, IN 47405-1405 (United States); Mastalerz, Maria [Indiana University, Indiana Geological Survey, Bloomington, IN 47405-2208 (United States); Pope, James [CRL Energy Ltd., 123 Blenheim Road, Christchurch (New Zealand); University of Canterbury, Dept. of Geological Sciences, Christchurch (New Zealand); Moore, Tim A. [University of Canterbury, Dept. of Geological Sciences, Christchurch (New Zealand); P.T. Arrow Energy Indonesia, Wisma Anugraha, Jl. Taman Kemang No. 32B, Jakarta Selatan (Indonesia)

    2010-01-07

    Desorption canisters are routinely employed to quantify coalbed gas contents in coals. If purging with inert gas or water flooding is not used, entrapment of air with {proportional_to} 78.08 vol.% nitrogen (N{sub 2}) in canisters during the loading of coal results in contamination by air and subsequent overestimates of N{sub 2} in desorbed coalbed gas. Pure coalbed gas does not contain any elemental oxygen (O{sub 2}), whereas air contamination originally includes {proportional_to} 20.95 vol.% O{sub 2} and has a N{sub 2}/O{sub 2} volume ratio of {proportional_to} 3.73. A correction for atmospheric N{sub 2} is often attempted by quantifying O{sub 2} in headspace gas and then proportionally subtracting atmospheric N{sub 2}. However, this study shows that O{sub 2} is not a conservative proxy for air contamination in desorption canisters. Time-series of gas chromatographic (GC) compositional data from several desorption experiments using high volatile bituminous coals from the Illinois Basin and a New Zealand subbituminous coal document that atmospheric O{sub 2} was rapidly consumed, especially during the first 24 h. After about 2 weeks of desorption, the concentration of O{sub 2} declined to near or below GC detection limits. Irreversible loss of O{sub 2} in desorption canisters is caused by biological, chemical, and physical mechanisms. The use of O{sub 2} as a proxy for air contamination is justified only immediately after loading of desorption canisters, but such rapid measurements preclude meaningful assessment of coalbed gas concentrations. With increasing time and progressive loss of O{sub 2}, the use of O{sub 2} content as a proxy for atmospheric N{sub 2} results in overestimates of N{sub 2} in desorbed coalbed gas. The indicated errors for nitrogen often range in hundreds of %. Such large analytical errors have a profound influence on market choices for CBM gas. An erroneously calculated N{sub 2} content in CBM would not meet specifications for most pipeline

  3. Coalbed gas desorption in canisters: Consumption of trapped atmospheric oxygen and implications for measured gas quality

    International Nuclear Information System (INIS)

    Jin, Hui; Schimmelmann, Arndt; Mastalerz, Maria; Pope, James; Moore, Tim A.

    2010-01-01

    Desorption canisters are routinely employed to quantify coalbed gas contents in coals. If purging with inert gas or water flooding is not used, entrapment of air with ∝ 78.08 vol.% nitrogen (N 2 ) in canisters during the loading of coal results in contamination by air and subsequent overestimates of N 2 in desorbed coalbed gas. Pure coalbed gas does not contain any elemental oxygen (O 2 ), whereas air contamination originally includes ∝ 20.95 vol.% O 2 and has a N 2 /O 2 volume ratio of ∝ 3.73. A correction for atmospheric N 2 is often attempted by quantifying O 2 in headspace gas and then proportionally subtracting atmospheric N 2 . However, this study shows that O 2 is not a conservative proxy for air contamination in desorption canisters. Time-series of gas chromatographic (GC) compositional data from several desorption experiments using high volatile bituminous coals from the Illinois Basin and a New Zealand subbituminous coal document that atmospheric O 2 was rapidly consumed, especially during the first 24 h. After about 2 weeks of desorption, the concentration of O 2 declined to near or below GC detection limits. Irreversible loss of O 2 in desorption canisters is caused by biological, chemical, and physical mechanisms. The use of O 2 as a proxy for air contamination is justified only immediately after loading of desorption canisters, but such rapid measurements preclude meaningful assessment of coalbed gas concentrations. With increasing time and progressive loss of O 2 , the use of O 2 content as a proxy for atmospheric N 2 results in overestimates of N 2 in desorbed coalbed gas. The indicated errors for nitrogen often range in hundreds of %. Such large analytical errors have a profound influence on market choices for CBM gas. An erroneously calculated N 2 content in CBM would not meet specifications for most pipeline-quality gas. (author)

  4. Recent advances in metal-organic frameworks and covalent organic frameworks for sample preparation and chromatographic analysis.

    Science.gov (United States)

    Wang, Xuan; Ye, Nengsheng

    2017-12-01

    In the field of analytical chemistry, sample preparation and chromatographic separation are two core procedures. The means by which to improve the sensitivity, selectivity and detection limit of a method have become a topic of great interest. Recently, porous organic frameworks, such as metal-organic frameworks (MOFs) and covalent organic frameworks (COFs), have been widely used in this research area because of their special features, and different methods have been developed. This review summarizes the applications of MOFs and COFs in sample preparation and chromatographic stationary phases. The MOF- or COF-based solid-phase extraction (SPE), solid-phase microextraction (SPME), gas chromatography (GC), high-performance liquid chromatography (HPLC) and capillary electrochromatography (CEC) methods are described. The excellent properties of MOFs and COFs have resulted in intense interest in exploring their performance and mechanisms for sample preparation and chromatographic separation. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Principles of qualitative analysis in the chromatographic context.

    Science.gov (United States)

    Valcárcel, M; Cárdenas, S; Simonet, B M; Carrillo-Carrión, C

    2007-07-27

    This article presents the state of the art of qualitative analysis in the framework of the chromatographic analysis. After establishing the differences between two main classes of qualitative analysis (analyte identification and sample classification/qualification) the particularities of instrumental qualitative analysis are commented on. Qualitative chromatographic analysis for sample classification/qualification through the so-called chromatographic fingerprint (for complex samples) or the volatiles profile (through the direct coupling headspace-mass spectrometry using the chromatograph as interface) is discussed. Next, more technical exposition of the qualitative chromatographic information is presented supported by a variety of representative examples.

  6. Magnesium ferrite nanoparticles: a rapid gas sensor for alcohol

    Science.gov (United States)

    Godbole, Rhushikesh; Rao, Pratibha; Bhagwat, Sunita

    2017-02-01

    Highly porous spinel MgFe2O4 nanoparticles with a high specific surface area have been successfully synthesized by a sintering free auto-combustion technique and characterized for their structural and surface morphological properties using XRD, BET, TEM and SEM techniques. Their sensing properties to alcohol vapors viz. ethanol and methanol were investigated. The site occupation of metal ions was investigated by VSM. The as-synthesized sample shows the formation of sponge-like porous material which is necessary for gas adsorption. The gas sensing characteristics were obtained by measuring the gas response as a function of operating temperature, concentration of the gas, and the response-recovery time. The response of magnesium ferrite to ethanol and methanol vapors was compared and it was revealed that magnesium ferrite is more sensitive and selective to ethanol vapor. The sensor operates at a substantially low vapor concentration of about 1 ppm of alcohol vapors, exhibits fantastic response reproducibility, long term reliability and a very fast response and recovery property. Thus the present study explored the possibility of making rapidly responding alcohol vapor sensor based on magnesium ferrite. The sensing mechanism has been discussed in co-relation with magnetic and morphological properties. The role of occupancy of Mg2+ ions in magnesium ferrite on its gas sensing properties has also been studied and is found to influence the response of magnesium ferrite ethanol sensor.

  7. Ion chromatographic determination of Di-n-butyl phosphate in degraded organic solvent

    International Nuclear Information System (INIS)

    Velavendan, P.; Pandey, N.K.; Kamachi Mudali, U.; Natarajan, R.

    2011-01-01

    In the present work a method for the determination of Di-n-butyl phosphate in organic streams using Ion Chromatography technique is developed and described here. The method involves the separation of Di-n-butyl phosphate (DBP) from 30% TBP-NPH (Tri-n-butylphosphate diluted in Normal Paraffin Hydrocarbon) and uranium/nitric acid matrix by an extraction of DBP in alkaline medium and subsequent ion-exchange separation in ion chromatography column followed by suppressed conductivity detection. Direct determination of DBP in lean/loaded organic solvent will lead to in accurate determination of DBP due to organic interference. DBP is quantified to lower limit of 1 ppm with 3% RSD. The results obtained with ion chromatographic technique are compared with those obtained by standard gas chromatographic technique. The developed method is much faster and total analysis can be completed within two hours. (author)

  8. Environmental Technology Verification Report. Field Portable Gas Chromatograph/Mass Spectrometer. Viking Instruments Corporation SpectraTrak (Trademark) 672

    National Research Council Canada - National Science Library

    Enfield, Wayne

    1997-01-01

    .... This self-contained, field transportable system, whose design has been adapted from laboratory technology, uses a contained, chromatographic column and accompanying mass spectrometer to provide...

  9. Evaluation of highly polar ionic liquid gas chromatographic column for the determination of the fatty acids in milk fat.

    Science.gov (United States)

    Delmonte, Pierluigi; Fardin-Kia, Ali Reza; Kramer, John K G; Mossoba, Magdi M; Sidisky, Len; Tyburczy, Cynthia; Rader, Jeanne I

    2012-04-13

    The SLB-IL111, a new ionic liquid capillary column for gas chromatography available from Supelco Inc., was recently shown to provide enhanced separation of unsaturated geometric and positional isomers of fatty acid (FAs) when it was compared to cyanopropylsiloxane (CPS) columns currently recommended for the analysis of fatty acid methyl esters (FAMEs). A 200 m SLB-IL111 capillary column, operated under a combined temperature and eluent flow gradient, was successfully used to resolve most of the FAs contained in milk fat in a single 80 min chromatographic separation. The selected chromatographic conditions provided a balanced, simultaneous separation of short-chain (from 4:0), long-chain polyunsaturated fatty acids (PUFAs), and most of the unsaturated FA positional/geometric isomers contained in milk fat. Among the monounsaturated fatty acids (MUFAs), these conditions separated t11-18:1 and t10-18:1 FAs, the two most abundant trans fatty acids (t-FA) contained in most dairy products. These t-FAs reportedly have different biological activities. The conjugated linoleic acid (CLA) isomers commonly found in dairy products were separated from each other, including t7,c9-18:2 from c9,t11-18:2, which eliminated the need for their complementary silver ion HPLC analysis. The application of the SLB-IL111 column provided a complementary elution profile of FAMEs to those obtained by CPS columns, allowing for a more comprehensive FA analysis of total milk fat. The FAMEs were identified by the use of available reference materials, previously synthesized and characterized reference mixtures, and prior separations of the milk fat FAMEs by silver ion chromatography based on the number/geometry of double bonds. Published by Elsevier B.V.

  10. Measurements of potato tubers gamma-ray irradiated in nitrogen gas or carbondioxide gas

    International Nuclear Information System (INIS)

    Katayama, Tadashi; Ohnishi, Tokuhiro; Dohmaru, Takaaki; Kanazawa, Tamotsu; Hiraoka, Eiichi; Furuta, Jun-ichiro.

    1984-01-01

    In this report the respiration of the potato tubers irradiated in nitrogen gas or carbondioxide gas was studied. Potato tubers of common Japanese variety, ''Danshaku'' were used for the examination. Potato tubers of about 2kg were put into each of Triple-Nylon bags and the bags were sealed after replacement of air in bags with nitrogen or carbondioxide gases. More than 16 hours after sealing of bags, the γ-dose ( 60 Co) of 150 Gy or 250 Gy were given to the potato tubers in bags at the dose rate of 10 4 R/h. After irradiation, all bags were opened in air and amounts of CO 2 released by respiration of tubers were measured with Hitachi gas chromatograph analyser Type 023. The amounts of CO 2 released from the potato tubers irradiated in open air is shown in Fig. 2. The results show that there is an initial lag period of several hours, followed by a rapid increase in the respiration, after which the CO 2 release was gradually decreased. Potato tubers irradiated in nitrogen gas show a similar release of CO 2 on time scale to the potato tubers irradiated in open air, but the total amounts of CO 2 are approximately half of those of the potato tubers irradiated in open air (Figs. 3 and 4). (J.P.N.)

  11. Results of gas monitoring of double-shell flammable gas watch list tanks

    International Nuclear Information System (INIS)

    Wilkins, N.E.

    1995-01-01

    Tanks 103-SY; 101-AW; 103-, 104-, and 105-AN are on the Flammable Gas Watch List. Recently, standard hydrogen monitoring system (SHMS) cabinets have been installed in the vent header of each of these tanks. Grab samples have been taken once per week, and a gas chromatograph was installed on tank 104-AN as a field test. The data that have been collected since gas monitoring began on these tanks are summarized in this document

  12. Large scale gas chromatographic demonstration system for hydrogen isotope separation

    International Nuclear Information System (INIS)

    Cheh, C.H.

    1988-01-01

    A large scale demonstration system was designed for a throughput of 3 mol/day equimolar mixture of H,D, and T. The demonstration system was assembled and an experimental program carried out. This project was funded by Kernforschungszentrum Karlsruhe, Canadian Fusion Fuel Technology Projects and Ontario Hydro Research Division. Several major design innovations were successfully implemented in the demonstration system and are discussed in detail. Many experiments were carried out in the demonstration system to study the performance of the system to separate hydrogen isotopes at high throughput. Various temperature programming schemes were tested, heart-cutting operation was evaluated, and very large (up to 138 NL/injection) samples were separated in the system. The results of the experiments showed that the specially designed column performed well as a chromatographic column and good separation could be achieved even when a 138 NL sample was injected

  13. Physicochemical, thin layer and gas-liquid chromatographic ...

    African Journals Online (AJOL)

    DELL

    2012-05-22

    May 22, 2012 ... PEG (3 m × 3 mm I. D.) was used for gas chromatography. Physicochemical analysis ... subjected to thin layer chromatography on plates (20 × 20 cm) having 0.25 mm thick silica gel ..... Headspace solid- phase microextraction ...

  14. Metal/glass composites for analysis of hydrogen isotopes by gas-chromatography

    International Nuclear Information System (INIS)

    Nicolae, Constantin Adrian; Sisu, Claudia; Stefanescu, Doina; Stanciu, Vasile

    1999-01-01

    The separation process of hydrogen isotopes by cryogenic distillation or thermal diffusion is a key technology for tritium separation from heavy water in CANDU reactor and for tritium fuel cycle in thermonuclear fusion reactor. In each process, analytical techniques for analyzing the hydrogen isotope mixture are required. An extensive experimental research has been carried out in order to produce the most suitable adsorbents and to establish the best operating conditions for selective separation and analysis of hydrogen isotopes by gas-chromatography. This paper describes the preparation of adsorbent materials used as stationary phases in the gas-chromatographic column for hydrogen isotope separation and the treatment (activation) of stationary phases. Modified thermoresisting glass with Fe(NH 4 ) 2 (SO 4 ) 2 ·6H 2 O and Cr 2 O 3 respectively have been experimentally investigated at 77 K for H 2 , HD and D 2 separation and the results of chromatographic runs are reported and discussed. The gas-chromatographic apparatus used in this study is composed of a Hewlett-Packard 7620A gas-chromatograph equipped with a gas carrier flow rate controller and a thermal conductivity detector. The apparatus comprises also a Dewar vessel containing the separation column. The hydrogen isotopes, H 2 , HD, D 2 , and their mixture have been obtained in our laboratories. The best operating conditions and parameters of the Fe 3+ /glass adsorbent column , i.e. granulometry, column length, pressure-drop along the column, carrier gas flow rate and sample volume have been studied by means of the analysis of the retention times, separation factors and HETP. (authors)

  15. Rapid determination of benzene derivatives in water samples by trace volume solvent DLLME prior to GC-FID

    Energy Technology Data Exchange (ETDEWEB)

    Diao, Chun Peng; Wei, Chao Hai; Feng, Chun Hua [South China Univ. of Technology, Guangzhou Higher Education Mega Center (China). College of Environmental Science and Engineering; Guangdong Regular Higher Education Institutions, Guangzhou (China). Key Lab. of Environmental Protection and Eco-Remediation

    2012-05-15

    An inexpensive, simple and environmentally friendly method based on dispersive liquid liquid microextraction (DLLME) for rapid determination of benzene derivatives in water samples was proposed. A significant improvement of DLLME procedure was achieved. Trace volume ethyl acetate (60 {mu}L) was exploited as dispersion solvent instead of common ones such as methanol and acetone, the volume of which was more than 0.5 mL, and the organic solvent required in DLLME was reduced to a great extent. Only 83-{mu}L organic solvent was consumed in the whole analytic process and the preconcentration procedure was less than 10 min. The advantageous approach coupled with gas chromatograph-flame ionization detector was proposed for the rapid determination of benzene, toluene, ethylbenzene and xylene isomers in water samples. Results showed that the proposed approach was an efficient method for rapid determination of benzene derivatives in aqueous samples. (orig.)

  16. Rapid differentiation of rocky mountain spotted fever from chickenpox, measles, and enterovirus infections and bacterial meningitis by frequency-pulsed electron capture gas-liquid chromatographic analysis of sera.

    Science.gov (United States)

    Brooks, J B; McDade, J E; Alley, C C

    1981-01-01

    Normal sera and sera from patients with Rocky Mountain spotted fever, chickenpox, enterovirus infections, measles, and Neisseria meningitidis infections were extracted with organic solvents under acidic and basic conditions and then derivatized with trichloroethanol or heptafluorobutyric anhydride-ethanol to form electron-capturing derivatives of organic acids, alcohols, and amines. The derivatives were analyzed by frequency-pulsed electron capture gas-liquid chromatography (FPEC-GLC). There were unique differences in the FPEC-GLC profiles of sera obtained from patients with these respective diseases. With Rocky Mountain spotted fever patients, typical profiles were detected as early as 1 day after onset of disease and before antibody could be detected in the serum. Rapid diagnosis of Rocky Mountain spotted fever by FPEC-GLC could permit early and effective therapy, thus preventing many deaths from this disease. PMID:7276147

  17. An aircraft gas chromatograph-mass spectrometer System for Organic Fast Identification Analysis (SOFIA): design, performance and a case study of Asian monsoon pollution outflow

    Science.gov (United States)

    Bourtsoukidis, Efstratios; Helleis, Frank; Tomsche, Laura; Fischer, Horst; Hofmann, Rolf; Lelieveld, Jos; Williams, Jonathan

    2017-12-01

    Volatile organic compounds (VOCs) are important for global air quality and oxidation processes in the troposphere. In addition to ground-based measurements, the chemical evolution of such species during transport can be studied by performing in situ airborne measurements. Generally, aircraft instrumentation needs to be sensitive, robust and sample at higher frequency than ground-based systems while their construction must comply with rigorous mechanical and electrical safety standards. Here, we present a new System for Organic Fast Identification Analysis (SOFIA), which is a custom-built fast gas chromatography-mass spectrometry (GC-MS) system with a time resolution of 2-3 min and the ability to quantify atmospheric mixing ratios of halocarbons (e.g. chloromethanes), hydrocarbons (e.g isoprene), oxygenated VOCs (acetone, propanal, butanone) and aromatics (e.g. benzene, toluene) from sub-ppt to ppb levels. The relatively high time resolution is the result of a novel cryogenic pre-concentration unit which rapidly cools (˜ 6 °C s-1) the sample enrichment traps to -140 °C, and a new chromatographic oven designed for rapid cooling rates (˜ 30 °C s-1) and subsequent thermal stabilization. SOFIA was installed in the High Altitude and Long Range Research Aircraft (HALO) for the Oxidation Mechanism Observations (OMO) campaign in August 2015, aimed at investigating the Asian monsoon pollution outflow in the tropical upper troposphere. In addition to a comprehensive instrument characterization we present an example monsoon plume crossing flight as a case study to demonstrate the instrument capability. Hydrocarbon, halocarbon and oxygenated VOC data from SOFIA are compared with mixing ratios of carbon monoxide (CO) and methane (CH4), used to define the pollution plume. By using excess (ExMR) and normalized excess mixing ratios (NEMRs) the pollution could be attributed to two air masses of distinctly different origin, identified by back-trajectory analysis. This work

  18. Chemically synthesized PbS Nano particulate thin films for a rapid NO2 gas sensor

    Directory of Open Access Journals (Sweden)

    Burungale Vishal V.

    2016-03-01

    Full Text Available Rapid NO2 gas sensor has been developed based on PbS nanoparticulate thin films synthesized by Successive Ionic Layer Adsorption and Reaction (SILAR method at different precursor concentrations. The structural and morphological properties were investigated by means of X-ray diffraction and field emission scanning electron microscope. NO2 gas sensing properties of PbS thin films deposited at different concentrations were tested. PbS film with 0.25 M precursor concentration showed the highest sensitivity. In order to optimize the operating temperature, the sensitivity of the sensor to 50 ppm NO2 gas was measured at different operating temperatures, from 50 to 200 °C. The gas sensitivity increased with an increase in operating temperature and achieved the maximum value at 150 °C, followed by a decrease in sensitivity with further increase of the operating temperature. The sensitivity was about 35 % for 50 ppm NO2 at 150 °C with rapid response time of 6 s. T90 and T10 recovery time was 97 s at this gas concentration.

  19. Total OH reactivity measurements using a new fast Gas Chromatographic Photo-Ionization Detector (GC-PID

    Directory of Open Access Journals (Sweden)

    V. Sinha

    2012-12-01

    Full Text Available The primary and most important oxidant in the atmosphere is the hydroxyl radical (OH. Currently OH sinks, particularly gas phase reactions, are poorly constrained. One way to characterize the overall sink of OH is to measure directly the ambient loss rate of OH, the total OH reactivity. To date, direct measurements of total OH reactivity have been either performed using a Laser-Induced Fluorescence (LIF system ("pump-and-probe" or "flow reactor" or the Comparative Reactivity Method (CRM with a Proton-Transfer-Reaction Mass Spectrometer (PTR-MS. Both techniques require large, complex and expensive detection systems. This study presents a feasibility assessment for CRM total OH reactivity measurements using a new detector, a Gas Chromatographic Photoionization Detector (GC-PID. Such a system is smaller, more portable, less power consuming and less expensive than other total OH reactivity measurement techniques.

    Total OH reactivity is measured by the CRM using a competitive reaction between a reagent (here pyrrole with OH alone and in the presence of atmospheric reactive molecules. The new CRM method for total OH reactivity has been tested with parallel measurements of the GC-PID and the previously validated PTR-MS as detector for the reagent pyrrole during laboratory experiments, plant chamber and boreal field studies. Excellent agreement of both detectors was found when the GC-PID was operated under optimum conditions. Time resolution (60–70 s, sensitivity (LOD 3–6 s−1 and overall uncertainty (25% in optimum conditions for total OH reactivity were similar to PTR-MS based total OH reactivity measurements. One drawback of the GC-PID system was the steady loss of sensitivity and accuracy during intensive measurements lasting several weeks, and a possible toluene interference. Generally, the GC-PID system has been shown to produce closely comparable results to the PTR-MS and thus in suitable environments (e.g. forests it

  20. Rapid hydrogen gas generation using reactive thermal decomposition of uranium hydride.

    Energy Technology Data Exchange (ETDEWEB)

    Kanouff, Michael P.; Van Blarigan, Peter; Robinson, David B.; Shugard, Andrew D.; Gharagozloo, Patricia E.; Buffleben, George M.; James, Scott Carlton; Mills, Bernice E.

    2011-09-01

    Oxygen gas injection has been studied as one method for rapidly generating hydrogen gas from a uranium hydride storage system. Small scale reactors, 2.9 g UH{sub 3}, were used to study the process experimentally. Complimentary numerical simulations were used to better characterize and understand the strongly coupled chemical and thermal transport processes controlling hydrogen gas liberation. The results indicate that UH{sub 3} and O{sub 2} are sufficiently reactive to enable a well designed system to release gram quantities of hydrogen in {approx} 2 seconds over a broad temperature range. The major system-design challenge appears to be heat management. In addition to the oxidation tests, H/D isotope exchange experiments were performed. The rate limiting step in the overall gas-to-particle exchange process was found to be hydrogen diffusion in the {approx}0.5 {mu}m hydride particles. The experiments generated a set of high quality experimental data; from which effective intra-particle diffusion coefficients can be inferred.

  1. Analysis of carbonyl compounds via headspace solid-phase microextraction with on-fiber derivatization and gas chromatographic-ion trap tandem mass spectrometric determination of their O-(2,3,4,5,6-pentafluorobenzyl)oxime derivatives

    Energy Technology Data Exchange (ETDEWEB)

    Schmarr, Hans-Georg [Dienstleistungszentrum Laendlicher Raum (DLR) Rheinpfalz, Breitenweg 71, D-67435 Neustadt an der Weinstrasse (Germany)], E-mail: hans-georg.schmarr@dlr.rlp.de; Potouridis, Theodoros; Ganss, Sebastian; Sang, Wei; Koepp, Benedikt; Bokuz, Ursula; Fischer, Ulrich [Dienstleistungszentrum Laendlicher Raum (DLR) Rheinpfalz, Breitenweg 71, D-67435 Neustadt an der Weinstrasse (Germany)

    2008-06-09

    An improved method for the analysis of carbonyls is described utilizing a headspace solid-phase microextraction (HS-SPME) step and on-fiber derivatization with O-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine (PFBHA) hydrochloride. Thermal desorption of the oxime derivatives formed on the fiber is followed by gas chromatographic separation coupled to an ion trap tandem mass spectrometer (GC-ITMS). Selecting specific fragment ions within the electron ionization (EI{sup +}) mass spectra of these oxime derivatives as precursor ions for MS-MS fragmentation provides a suitable method for the target analysis of individual carbonyl classes, such as alkanals, (E)-2-alkenals, (E,E)-2,4-alkadienals, and others. Retention indices on polar as well as on apolar stationary phases along with EI{sup +} mass spectra patterns are presented for a large set of oxime derivatives, giving valuable information needed for unambiguous assignment of substances in complex sample matrices. The fast sample preparation and derivatization step via HS-SPME can be automated and is applicable to a variety of biological samples and foodstuffs, allowing rapid and sensitive screening analyses of important aldehydic biomarkers and aroma active compounds.

  2. Method for the routine quantitative gas chromatographic analysis of major free fatty acids in butter and cream.

    Science.gov (United States)

    Woo, A H; Lindsay, R C

    1980-07-01

    A rapid quantiative method was developed for routine analysis of the major, even carbon-numbered free fatty acids in butter and cream. Free fatty acids were isolated directly from intact samples by a modified silicic acid-potassium hydroxide arrestant column and were separated by gas chromatography with a 1.8 m x 2 mm inner diameter glass column packed with 10% neopentyl glycol adipate on 80/100 Chromosorb W. Purified, formic acid-saturated carrier gas was required for minimal peak tailing and extended column life. The accuracy and reproducibility of the mmethod was established through quantitative recovery studies of free fatty acid mixtures, free fatty acids added to butter, and replicate analysis of butter and cream samples.

  3. Chromatographic and electrophoretic approaches in ink analysis.

    Science.gov (United States)

    Zlotnick, J A; Smith, F P

    1999-10-15

    Inks are manufactured from a wide variety of substances that exhibit very different chemical behaviors. Inks designed for use in different writing instruments or printing methods have quite dissimilar components. Since the 1950s chromatographic and electrophoretic methods have played important roles in the analysis of inks, where compositional information may have bearing on the investigation of counterfeiting, fraud, forgery, and other crimes. Techniques such as paper chromatography and electrophoresis, thin-layer chromatography, high-performance liquid chromatography, gas chromatography, gel electrophoresis, and the relatively new technique of capillary electrophoresis have all been explored as possible avenues for the separation of components of inks. This paper reviews the components of different types of inks and applications of the above separation methods are reviewed.

  4. Improvement of gas chromatographic analysis for organic acids and ...

    African Journals Online (AJOL)

    Yomi

    2010-08-27

    Aug 27, 2010 ... short retention time and fair recognition peak of the compounds were obtained under the ... GC for acid and solvent analysis from ABE fermentation ... FID was kept at 230°C. Nitrogen gas was used as a carrier gas at a.

  5. Ion Chromatographic Analyses of Sea Waters, Brines and Related Samples

    Directory of Open Access Journals (Sweden)

    Nataša Gros

    2013-06-01

    Full Text Available This review focuses on the ion chromatographic methods for the analyses of natural waters with high ionic strength. At the beginning a natural diversity in ionic composition of waters is highlighted and terminology clarified. In continuation a brief overview of other review articles of potential interest is given. A review of ion chromatographic methods is organized in four sections. The first section comprises articles focused on the determination of ionic composition of water samples as completely as possible. The sections—Selected Anions, Selected Cations and Metals—follow. The most essential experimental conditions used in different methods are summarized in tables for a rapid comparison. Techniques encountered in the reviewed articles comprise: direct determinations of ions in untreated samples with ion- or ion-exclusion chromatography, or electrostatic ion chromatography; matrix elimination with column-switching; pre-concentration with a chelation ion chromatography and purge-and-trap pre-concentration. Different detection methods were used: non-suppressed conductometric or suppressed conductometric, direct spectrometric or spectrometric after a post-column derivetization, and inductively coupled plasma in combination with optical emission or mass spectrometry.

  6. Technical artifacts in chromatographic analysis of Tc-99m radiopharmaceuticals

    International Nuclear Information System (INIS)

    Kowalsky, R.J.; Creekmore, J.R.

    1982-01-01

    Technical artifacts produced during chromatographic analysis of technetium radiopharmaceuticals were investigated. Such artifacts are, we found, caused by improper spotting and drying techniques; these in turn produce spuriously high impurities in Tc-99m complexes of DTPA, MDP, PPi, and GH. The ITLC-SG/acetone system produces considerable streaking of Tc-complex if the applied spot is large and not dried before development. This results in activity in the solvent front portion of the chromatographic strip indicating falsely high levels of pertechnetate impurity. Proper drying of the applied spot eliminates the artifact. The ITLC-SG/saline system yields falsely high, hydrolyzed-reduced technetium impurities if the spot is allowed to enter the solvent during development. Correct spot placement and size eliminate this problem. Strips that are allowed to dry in room air for several minutes may indicate considerable pertechnetate impurity on the chromatogram; yet this may not actually be present in the radiopharmaceutical vial. Drying spots rapidly with hot air or in a nitrogen atmosphere before development eliminates this problem

  7. A novel headspace gas chromatographic method for in situ monitoring of monomer conversion during polymerization in an emulsion environment.

    Science.gov (United States)

    Chai, Xin-Sheng; Zhong, Jin-Feng; Hu, Hui-Chao

    2012-05-18

    This paper describes a novel multiple-headspace extraction/gas chromatographic (MHE-GC) technique for monitoring monomer conversion during a polymerization reaction in a water-based emulsion environment. The polymerization reaction of methyl methacrylate (MMA) in an aqueous emulsion is used as an example. The reaction was performed in a closed headspace sample vial (as a mini-reactor), with pentane as a tracer. In situ monitoring of the vapor concentration of the tracer, employing a multiple headspace extraction (sampling) scheme, coupled to a GC, makes it possible to quantitatively follow the conversion of MMA during the early stages of polymerization. Data on the integrated amount of the tracer vapor released from the monomer droplet phase during the polymerization is described by a mathematic equation from which the monomer conversion can be calculated. The present method is simple, automated and economical, and provides an efficient tool in the investigation of the reaction kinetics and effects of the reaction conditions on the early stage of polymerization. Copyright © 2012 Elsevier B.V. All rights reserved.

  8. Catalyst functionalized buffer sorbent pebbles for rapid separation of carbon dioxide from gas mixtures

    Energy Technology Data Exchange (ETDEWEB)

    Aines, Roger D

    2015-03-31

    A method for separating CO.sub.2 from gas mixtures uses a slurried media impregnated with buffer compounds and coating the solid media with a catalyst or enzyme that promotes the transformation of CO.sub.2 to carbonic acid. Buffer sorbent pebbles with a catalyst or enzyme coating are provided for rapid separation of CO.sub.2 from gas mixtures.

  9. Catalyst functionalized buffer sorbent pebbles for rapid separation of carbon dioxide from gas mixtures

    Science.gov (United States)

    Aines, Roger D.

    2013-03-12

    A method for separating CO.sub.2 from gas mixtures uses a slurried media impregnated with buffer compounds and coating the solid media with a catalyst or enzyme that promotes the transformation of CO.sub.2 to carbonic acid. Buffer sorbent pebbles with a catalyst or enzyme coating are provided for rapid separation of CO.sub.2 from gas mixtures.

  10. Chemically modified glasses for analysis of hydrogen isotopes by gas-chromatography

    International Nuclear Information System (INIS)

    Stanciu, Vasile; Stefanescu, Doina

    1999-01-01

    Hydrogen isotope separation process by such methods as cryogenic distillation or thermal diffusion method is one of the key technologies of the tritium separation from heavy water of CANDU reactors and in the tritium fuel cycle for a thermonuclear fusion reactor. In each process, the analytical techniques for measuring contents of hydrogen isotope mixture are necessary. An extensive experimental research has been carried out in order to produce the most suitable absorbent and define the best operating conditions for selective separation and analysis of hydrogen isotope by gas-chromatography. This paper describes the preparation of adsorbent materials utilised as stationary phase in the gas-chromatographic column for hydrogen isotope separation and treatment (activation) of stationary phase. Modified thermo-resisting glass with Fe(NH 4 ) 2 (SO 4 ) 2 6H 2 O and Cr 2 O 3 , respectively, have been experimentally investigated at 77 K for H 2 , HD and D 2 separation and the results of chromatographic runs are also reported and discussed. The gas-chromatographic apparatus used is composed of a Hewlett-Packard 7620A gas-chromatograph equipped with a gas carrier flow rate controller and a thermal conductivity detector (TCD). The apparatus comprises also a Dewar vessel containing the separation column. The hydrogen isotopes H 2 , HD, D 2 and their mixture have been obtained in our laboratories. The best operating conditions of the adsorbent column Fe (III)/glass and Cr 2 O 3 /glass, i.e. granulometry, column length, pressure-drop along the column, carrier gas flow rate, sample volume have been studied by means of the analysis of the retention times, separation factors and HETP. (authors)

  11. A new fiber-optic sensor technology for rapid and inexpensive characterization of soil contamination

    International Nuclear Information System (INIS)

    Milanovich, F.P.; Brown, S.B.; Colston, B.W. Jr.; Daley, P.F.; Rossabi, J.

    1993-04-01

    The extent and complexity of worldwide environmental contamination are great enough that remediation will be extremely costly and lengthy. There is an urgent need for characterization techniques that are rapid, inexpensive, and simple and that do not generate waste. Towards this end LLNL is developing a fiber-optic chemical sensor technology for use in groundwater and vadose-zone monitoring. We use a colorimetric detection technique, based on an irreversible chemical reaction between a specific reagent and the target compound. The accuracy and sensitivity of the sensor (<5 ppb by weight in water, determined by comparison with gas chromatographic standard measurements) are sufficient for environmental monitoring of at least trichloroethylene (TCE) and chloroform

  12. Chromatographic hydrogen isotope separation

    International Nuclear Information System (INIS)

    Aldridge, F.T.

    1983-01-01

    Intermetallic compounds with the CaCu5 type of crystal structure, particularly LaNiCo and CaNi5, exhibit high separation factors and fast equilibrium times and therefore are useful for packing a chromatographic hydrogen isotope separation column. The addition of an inert metal to dilute the hydride improves performance of the column. A large scale multi-stage chromatographic separation process run as a secondary process off a hydrogen feedstream from an industrial plant which uses large volumes of hydrogen can produce large quantities of heavy water at an effective cost for use in heavy water reactors

  13. Chromatographic hydrogen isotope separation

    International Nuclear Information System (INIS)

    Aldridge, F.T.

    1981-01-01

    Intermetallic compounds with the CaCu5 type of crystal structure , particularly LaNiCo and CaNi5, exhibit high separation factors and fast equilibrium times and therefore are useful for packing a chromatographic hydrogen isotope separation colum. The addition of an inert metal to dilute the hydride improves performance of the column. A large scale mutli-stage chromatographic separation process run as a secondary process off a hydrogen feedstream from an industrial plant which uses large volumes of hydrogen can produce large quantities of heavy water at an effective cost for use in heavy water reactors

  14. Measurement of Activity Coefficients of Solvents in Poly ( ethylene oxide ) Using Gas-Chromatographic Method and Correlation by Polymer-ASOG; Poriechirenokishido chu no yobai katsuryo keisu no gasukuromatogurafu ho ni yoru sokutei to Polymer-ASOG ni yoru sokan

    Energy Technology Data Exchange (ETDEWEB)

    Tochigi, K.; Kurita, S.; Ohashi, M. [Yuki Gosei Kogyo Co. LTd., (Japan); Kojima, K. [Nihon University, Tokyo (Japan). Department of Industrial Chemistry

    1997-09-01

    Infinite dilution activity coefficients (353.15-393.15 K) of six solvents (benzene, toluene, p-xylene, cyclohexane, acetone and methylethylketone) and activity coefficient at finite concentrations (353.15 K, 373.15 K) of these solvents in poly (ethylene oxide) are measured using gas-chromatographic method. The experimental data are then correlated by a polymer-ASOG model. 18 refs., 2 figs., 3 tabs.

  15. Recent developments on field gas extraction and sample preparation methods for radiokrypton dating of groundwater

    Science.gov (United States)

    Yokochi, Reika

    2016-09-01

    Current and foreseen population growths will lead to an increased demand in freshwater, large quantities of which is stored as groundwater. The ventilation age is crucial to the assessment of groundwater resources, complementing the hydrological model approach based on hydrogeological parameters. Ultra-trace radioactive isotopes of Kr (81 Kr and 85 Kr) possess the ideal physical and chemical properties for groundwater dating. The recent advent of atom trap trace analyses (ATTA) has enabled determination of ultra-trace noble gas radioisotope abundances using 5-10 μ L of pure Kr. Anticipated developments will enable ATTA to analyze radiokrypton isotope abundances at high sample throughput, which necessitates simple and efficient sample preparation techniques that are adaptable to various sample chemistries. Recent developments of field gas extraction devices and simple and rapid Kr separation method at the University of Chicago are presented herein. Two field gas extraction devices optimized for different sampling conditions were recently designed and constructed, aiming at operational simplicity and portability. A newly developed Kr purification system enriches Kr by flowing a sample gas through a moderately cooled (138 K) activated charcoal column, followed by a gentle fractionating desorption. This simple process uses a single adsorbent and separates 99% of the bulk atmospheric gases from Kr without significant loss. The subsequent two stages of gas chromatographic separation and a hot Ti sponge getter further purify the Kr-enriched gas. Abundant CH4 necessitates multiple passages through one of the gas chromatographic separation columns. The presented Kr separation system has a demonstrated capability of extracting Kr with > 90% yield and 99% purity within 75 min from 1.2 to 26.8 L STP of atmospheric air with various concentrations of CH4. The apparatuses have successfully been deployed for sampling in the field and purification of groundwater samples.

  16. Gas chromatography of adducts of rare earth dipivaloylmethanates with triphenylphosphine oxide

    International Nuclear Information System (INIS)

    Magazeeva, N.V.; Martynenko, L.I.; Murav'eva, I.A.; Spitsyn, V.I.

    1987-01-01

    A gas chromatographic method for determination of stability provisional constants of dipivaloylmethanates of REE with triphenylphosphine oxide is suggested, and ML 3 xTPPO adduct stability is shown to decrease in Ho-Lu series. ML 3 chromatographing at the presence of TPPO is stated to increase the coefficients of REE separation

  17. Chromatographic enrichment of isotopes in hydrogen and water samples on palladium

    International Nuclear Information System (INIS)

    Andreev, B.M.; Polevoi, A.S.; Perevezentsev, A.N.

    1987-01-01

    Data on the isotopic enrichment of hydrogen and water samples by chromatography on palladium have been analyzed. Experimental data on the effect of temperature, hydrogen flow, volume of the enriched fraction, and length of the chromatographic column on the degree of separation attainable in the column have been obtained. It has been shown that the maximum separation achievable (regardless of the type of the isotope mixture) at 273 K falls with increase of hydrogen flow and volume of the enriched gas fraction recoverable from the column. A separation degree of ∼ 1040 has been achieved for a mixture of protium and deuterium in a 10-mm wide and 0.6-m long chromatographic column packed with palladium black with a grain size of 0.2-0.5 mm at 273 K and a specific hydrogen flow of 1.22 mole/m 2 x sec. For a protium-tritium mixture a separation degree of ∼ 90 has been reached in a similar column at 273 K and a specific hydrogen flow of 0.4 mole/m 2 x sec

  18. Portable rapid gas content measurement - an opportunity for a step change in the coal industry?

    International Nuclear Information System (INIS)

    Beamish, Basil; Kizil, Mehmet; Gu, Ming

    2013-01-01

    The last major advance in gas content measurement for coal seams was the introduction of the quick crush technique in the early 1990s. This is a laboratory test method that has proven very reliable over the years. Recent laboratory testing using a portable quick crushing device, known as the portable gas content analyser, has produced consistent gas content results for a set of core samples obtained from a single borehole that intersected four coal seams. The retained gas content values obtained for the seams show the same increasing gas content pattern and gas composition change with depth as the standard quick crush technique. Use of the portable gas content analyser provides the opportunity to produce rapid, reliable gas content measurement of coal that could be developed for assessing gas compliance cores and outburst-prone conditions at a mine site.

  19. Gas and particle motions in a rapidly decompressed flow

    Science.gov (United States)

    Johnson, Blair; Zunino, Heather; Adrian, Ronald; Clarke, Amanda

    2017-11-01

    To understand the behavior of a rapidly decompressed particle bed in response to a shock, an experimental study is performed in a cylindrical (D = 4.1 cm) glass vertical shock tube of a densely packed (ρ = 61%) particle bed. The bed is comprised of spherical glass particles, ranging from D50 = 44-297 μm between experiments. High-speed pressure sensors are incorporated to capture shock speeds and strengths. High-speed video and particle image velocimetry (PIV) measurements are collected to examine vertical and radial velocities of both the particles and gas to elucidate features of the shock wave and resultant expansion wave in the lateral center of the tube, away from boundaries. In addition to optically analyzing the front velocity of the rising particle bed, interaction between the particle and gas phases are investigated as the flow accelerates and the particle front becomes more dilute. Particle and gas interactions are also considered in exploring mechanisms through which turbulence develops in the flow. This work is supported by the U.S. Department of Energy, National Nuclear Security Administration, Advanced Simulation and Computing Program, as a Cooperative Agreement under the Predictive Science and Academic Alliance Program, under Contract No. DE-NA0002378.

  20. Single-column extraction chromatographic separation of U, Pu, Np and Am

    Energy Technology Data Exchange (ETDEWEB)

    Morgenstern, A.; Apostolidis, C.; Carlos-Marquez, R.; Mayer, K.; Molinet, R. [Commission of the European Communities, Karlsruhe (Germany). European Inst. for Transuranium Elements

    2002-07-01

    A rapid, single-column extraction chromatographic method using commercially available UTEVA resin has been developed for the separation of uranium, plutonium, neptunium and americium. The method yields recoveries superior to 90% and allows direct loading of separated fractions on filaments for subsequent analysis by thermal ionization mass spectrometry. The use of reagents compatible with robotized equipment allows automation of the separation process for routine analysis of nuclear materials. The redox reactions between plutonium, neptunium and hydrogen peroxide involved in the separation process were studied by UV/Vis/NIR absorption spectroscopy. (orig.)

  1. [Determination of olive oil content in olive blend oil by headspace gas chromatography-mass spectrometry].

    Science.gov (United States)

    Jiang, Wanfeng; Zhang, Ning; Zhang, Fengyan; Yang, Zhao

    2017-07-08

    A method for the determination of the content of olive oil in olive blend oil by headspace gas chromatography-mass spectrometry (SH-GC/MS) was established. The amount of the sample, the heating temperature, the heating time, the amount of injection, the injection mode and the chromatographic column were optimized. The characteristic compounds of olive oil were found by chemometric method. A sample of 1.0 g was placed in a 20 mL headspace flask, and heated at 180℃ for 2700 s. Then, 1.0 mL headspace gas was taken into the instrument. An HP-88 chromatographic column was used for the separation and the analysis was performed by GC/MS. The results showed that the linear range was 0-100%(olive oil content). The linear correlation coefficient ( r 2 ) was more than 0.995, and the limits of detection were 1.26%-2.13%. The deviations of olive oil contents in the olive blend oil were from -0.65% to 1.02%, with the relative deviations from -1.3% to 6.8% and the relative standard deviations from 1.18% to 4.26% ( n =6). The method is simple, rapid, environment friendly, sensitive and accurate. It is suitable for the determination of the content of olive oil in olive blend oil.

  2. Evaluation of a portable gas chromatograph with photoionization detector under variations of VOC concentration, temperature, and relative humidity.

    Science.gov (United States)

    Soo, Jhy-Charm; Lee, Eun Gyung; LeBouf, Ryan F; Kashon, Michael L; Chisholm, William; Harper, Martin

    2018-04-01

    The objective of this present study was to evaluate the performance of a portable gas chromatograph-photoionization detector (GC-PID), under various test conditions to determine if it could be used in occupational settings. A mixture of 7 volatile organic compounds (VOCs)-acetone, ethylbenzene, methyl isobutyl ketone, toluene, m-xylene, p-xylene, and o-xylene-was selected because its components are commonly present in paint manufacturing industries. A full-factorial combination of 4 concentration levels (exposure scenarios) of VOC mixtures, 3 different temperatures (25°C, 30°C, and 35°C), and 3 relative humidities (RHs; 25%, 50%, and 75%) was conducted in a full-size controlled environmental chamber. Three repetitions were conducted for each test condition allowing for estimation of accuracy. Time-weighted average exposure data were collected using solid sorbent tubes (Anasorb 747, SKC Inc.) as the reference sampling medium. Calibration curves of Frog-4000 using the dry gases showed R 2 > 0.99 for all analytes except for toluene (R 2 = 0.97). Frog-4000 estimates within a test condition showed good consistency for the performance of repeated measurement. However, there was ∼41-64% reduction in the analysis of polar acetone with 75% RH relative to collection at 25% RH. Although Frog-4000 results correlated well with solid sorbent tubes (r = 0.808-0.993, except for toluene) most of the combinations regardless of analyte did not meet the <25% accuracy criterion recommended by NIOSH. The effect of chromatographic co-elution can be seen with m, p-xylene when the results are compared to the sorbent tube sampling technique with GC-flame ionization detector. The results indicated an effect of humidity on the quantification of the polar compounds that might be attributed to the pre-concentrator placed in the selected GC-PID. Further investigation may resolve the humidity effect on sorbent trap with micro GC pre-concentrator when water vapor is present. Although this

  3. A gas chromatograph system for semi-continuous greenhouse gas measurements at Puy de Dôme station, Central France

    Science.gov (United States)

    Lopez, M.; Schmidt, M.; Ramonet, M.; Bonne, J.-L.; Colomb, A.; Kazan, V.; Laj, P.; Pichon, J.-M.

    2015-03-01

    Three years of greenhouse gases measurements, obtained using a gas chromatograph (GC) system located at the Puy de Dôme station at 1465 m a.s.l. in Central France are presented. The GC system was installed in 2010 at Puy de Dôme and was designed for automatic and accurate semi-continuous measurements of atmospheric carbon dioxide, methane, nitrous oxide and sulfur hexafluoride mole fractions. We present in detail the instrumental set up and the calibration strategy, which together allow the GC to reach repeatabilities of 0.1 μmol mol-1, 1.2, 0.3 nmol mol-1 and 0.06 pmol mol-1 for CO2, CH4, N2O and SF6, respectively. Comparisons of the atmospheric time series with those obtained using other instruments shown that the GC system meets the World Meteorological Organization recommendations. The analysis of the three-year atmospheric time series revealed how the planetary boundary layer height drives the mole fractions observed at a mountain site such as Puy de Dôme where air masses alternate between the planetary boundary layer and the free troposphere. Accurate long-lived greenhouse gases measurements collocated with 222Rn measurements as an atmospheric tracer, allowed us to determine the CO2, CH4 and N2O emissions in the catchment area of the station. The derived CO2 surface flux revealed a clear seasonal cycle with net uptake by plant assimilation in the spring and net emission caused by the biosphere and burning of fossil fuel during the remainder of the year. We calculated a mean annual CO2 flux of 1150 t(CO2) km-2. The derived CH4 and N2O emissions in the station catchment area were 5.6 t(CH4) km-2 yr-1 and 1.5 t(N2O) km-2 yr-1, respectively. Our derived annual CH4 flux is in agreement with the national French inventory, whereas our derived N2O flux is five times larger than the same inventory.

  4. Probabilistic peak detection for first-order chromatographic data.

    Science.gov (United States)

    Lopatka, M; Vivó-Truyols, G; Sjerps, M J

    2014-03-19

    We present a novel algorithm for probabilistic peak detection in first-order chromatographic data. Unlike conventional methods that deliver a binary answer pertaining to the expected presence or absence of a chromatographic peak, our method calculates the probability of a point being affected by such a peak. The algorithm makes use of chromatographic information (i.e. the expected width of a single peak and the standard deviation of baseline noise). As prior information of the existence of a peak in a chromatographic run, we make use of the statistical overlap theory. We formulate an exhaustive set of mutually exclusive hypotheses concerning presence or absence of different peak configurations. These models are evaluated by fitting a segment of chromatographic data by least-squares. The evaluation of these competing hypotheses can be performed as a Bayesian inferential task. We outline the potential advantages of adopting this approach for peak detection and provide several examples of both improved performance and increased flexibility afforded by our approach. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Fast temperature programming in gas chromatography using resistive heating

    NARCIS (Netherlands)

    Dallüge, J.; Ou-Aissa, R.; Vreuls, J.J.; Brinkman, U.A.T.; Veraart, J.R.

    1999-01-01

    The features of a resistive-heated capillary column for fast temperature-programmed gas chromatography (GC) have been evaluated. Experiments were carried out using a commercial available EZ Flash GC, an assembly which can be used to upgrade existing gas chromatographs. The capillary column is placed

  6. Further Validation of a Rapid Screening Semiquantitative Thin-Layer Chromatographic Method for Marketed Antimalarial Medicines for Adoption in Malawi

    Directory of Open Access Journals (Sweden)

    Dorcas Osei-Safo

    2018-01-01

    Full Text Available A recently developed semiquantitative thin-layer chromatographic (SQ-TLC assay has been employed in postmarketing surveillance of antimalarial medicines used in Malawi prior to HPLC assay. Both methods gave analogous results in a significant majority of the samples, with a good correlation (r = 0.9012 for the active pharmaceutical ingredients of the dosage forms assayed. Artemether-containing medicines had the highest percentage (92.67% of samples with comparable results for both assays. The lowest percentage (66.67% was observed in artesunate-containing medicines. The SQ-TLC method was validated for specificity, accuracy, precision, linearity, and stability according to the International Conference on Harmonisation guidelines, with the results falling within acceptable limits. For specificity, retention factor values of the test samples and reference standards were comparable, while accuracy and precision of 91.1 ± 5.7% were obtained for all samples. The method was linear in the range 1.0–2.0 µg/spot with a correlation coefficient of r = 0.9783. Stability tests also fell within acceptable limits. In this study, we present the validation of the SQ-TLC method and propose its adoption as a rapid screening tool for field estimation of the quality of antimalarial and other essential medicines in Malawi and other parts of the developing world prior to a more accurate HPLC assay.

  7. A low thermal mass fast gas chromatograph and its implementation in fast gas chromatography mass spectrometry with supersonic molecular beams.

    Science.gov (United States)

    Fialkov, Alexander B; Moragn, Mati; Amirav, Aviv

    2011-12-30

    A new type of low thermal mass (LTM) fast gas chromatograph (GC) was designed and operated in combination with gas chromatography mass spectrometry (GC-MS) with supersonic molecular beams (SMB), including GC-MS-MS with SMB, thereby providing a novel combination with unique capabilities. The LTM fast GC is based on a short capillary column inserted inside a stainless steel tube that is resistively heated. It is located and mounted outside the standard GC oven on its available top detector port, while the capillary column is connected as usual to the standard GC injector and supersonic molecular beam interface transfer line. This new type of fast GC-MS with SMB enables less than 1 min full range temperature programming and cooling down analysis cycle time. The operation of the fast GC-MS with SMB was explored and 1 min full analysis cycle time of a mixture of 16 hydrocarbons in the C(10)H(22) up to C(44)H(90) range was achieved. The use of 35 mL/min high column flow rate enabled the elution of C(44)H(90) in less than 45 s while the SMB interface enabled splitless acceptance of this high flow rate and the provision of dominant molecular ions. A novel compound 9-benzylazidanthracene was analyzed for its purity and a synthetic chemistry process was monitored for the optimization of the chemical reaction yield. Biodiesel was analyzed in jet fuel (by both GC-MS and GC-MS-MS) in under 1 min as 5 ppm fatty acid methyl esters. Authentic iprodion and cypermethrin pesticides were analyzed in grapes extract in both full scan mode and fast GC-MS-MS mode in under 1 min cycle time and explosive mixture including TATP, TNT and RDX was analyzed in under 1 min combined with exhibiting dominant molecular ion for TATP. Fast GC-MS with SMB is based on trading GC separation for speed of analysis while enhancing the separation power of the MS via the enhancement of the molecular ion in the electron ionization of cold molecules in the SMB. This paper further discusses several features of

  8. In situ alcoholysis of triacylglycerols by application of switchable-polarity solvents. A new derivatization procedure for the gas-chromatographic analysis of vegetable oils.

    Science.gov (United States)

    Saliu, Francesco; Orlandi, Marco

    2013-10-01

    We describe a new use of switchable-polarity solvents for the simultaneous derivatization and extraction of triacylglycerols from vegetable oils before gas-chromatographic analysis. Different equimolecular mixtures of the commercially available amidine 1,8-diazabicyclo[5.4.0]undec-7-ene and n-alkyl alcohols were tested. Triolein was used as a model compound. Very good results were achieved by using butanol (recovery of butyl oleate was 89 ± 4%). The procedure was applied for the characterization of the fatty acid profile of different vegetable oils. No statistically significant differences from the results obtained with the application of two traditional methods were evidenced. Moreover, the use of switchable-polarity solvents showed many advantages: owing to the basicity of the amidines, no catalyst was required; the transterification reaction was conducted under mild conditions, one step and in situ; no particular matrix interferences were evidenced; the solvent was recovered.

  9. Selective removal of water in purge and cold-trap capillary gas chromatographic analysis of volatile organic traces in aqueous samples

    NARCIS (Netherlands)

    Noij, T.H.M.; van Es, A.J.J.; Cramers, C.A.M.G.; Rijks, J.A.; Dooper, R.P.M.

    1987-01-01

    The design and features of an on-line purge and cold-trap pre-concentration device for rapid analysis of volatile organic compounds in aqueous samples are discussed. Excessive water is removed from the purge gas by a condenser or a water permeable membrane in order to avoid blocking of the capillary

  10. Improved Chromatographic Bioavailability Estimations

    National Research Council Canada - National Science Library

    Dorsey, John

    1996-01-01

    .... Since the inception of reversed phase liquid chromatography there have been many attempts to correlate chromatographic retention with bioavailability and the most often used bulk measure, the octanol...

  11. Application of gas chromatography in hydrogen isotope separation

    International Nuclear Information System (INIS)

    Ye Xiaoqiu; Sang Ge; Peng Lixia; Xue Yan; Cao Wei

    2008-01-01

    The principle of gas chromatographic separation of hydrogen isotopes was briefly introduced. The main technology and their development of separating hydrogen isotopes, including elution chromatography, hydrogen-displacement chromatography, self-displacement chromatography and frontal chromatography were discussed in detail. The prospect of hydrogen isotope separation by gas chromatography was presented. (authors)

  12. Effects of chromatographic fractions of Euphorbia hirta on the rat ...

    African Journals Online (AJOL)

    The effects of the chromatographic fractions of Euphorbia hirta Linn on the serum biochemical parameters in rats were investigated. The ethanolic extract of this plant was subjected to chromatographic separation using the vacuum liquid chromatographic technique, a modified form of classical column chromatography.

  13. Rapid and selective detection of acetone using hierarchical ZnO gas sensor for hazardous odor markers application.

    Science.gov (United States)

    Jia, Qianqian; Ji, Huiming; Zhang, Ying; Chen, Yalu; Sun, Xiaohong; Jin, Zhengguo

    2014-07-15

    Hierarchical nanostructured ZnO dandelion-like spheres were synthesized via solvothermal reaction at 200°C for 4h. The products were pure hexagonal ZnO with large exposure of (002) polar facet. Side-heating gas sensor based on hierarchical ZnO spheres was prepared to evaluate the acetone gas sensing properties. The detection limit to acetone for the ZnO sensor is 0.25ppm. The response (Ra/Rg) toward 100ppm acetone was 33 operated at 230°C and the response time was as short as 3s. The sensor exhibited remarkable acetone selectivity with negligible response toward other hazardous gases and water vapor. The high proportion of electron depletion region and oxygen vacancies contributed to high gas response sensitivity. The hollow and porous structure of dandelion-like ZnO spheres facilitated the diffusion of gas molecules, leading to a rapid response speed. The largely exposed (002) polar facets could adsorb acetone gas molecules easily and efficiently, resulting in a rapid response speed and good selectivity of hierarchical ZnO spheres gas sensor at low operating temperature. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Rapid chromatographic separation of dissoluble Ag(I) and silver-containing nanoparticles of 1-100 nanometer in antibacterial products and environmental waters.

    Science.gov (United States)

    Zhou, Xiao-Xia; Liu, Rui; Liu, Jing-Fu

    2014-12-16

    Sensitive and rapid methods for speciation analysis of nanoparticulate Ag (NAg) and Ag(I) in complex matrices are urgently needed for understanding the environmental effects and biological toxicity of silver nanoparticles (AgNPs). Herein we report the development of a universal liquid chromatography (LC) method for rapid and high resolution separation of dissoluble Ag(I) from nanoparticles covering the entire range of 1-100 nm in 5 min. By using a 500 Å poresize amino column, and an aqueous mobile phase containing 0.1% (v/v) FL-70 (a surfactant) and 2 mM Na2S2O3 at a flow rate of 0.7 mL/min, all the nanoparticles of various species such as Ag and Ag2S were eluted in one fraction, while dissoluble Ag(I) was eluted as a baseline separated peak. The dissoluble Ag(I) was quantified by the online coupled ICP-MS with a detection limit of 0.019 μg/L. The NAg was quantified by subtracting the dissoluble Ag(I) from the total Ag content, which was determined by ICP-MS after digestion of the sample without LC separation. While the addition of FL-70 and Na2S2O3 into the mobile phase is essential to elute NAg and Ag(I) from the column, the use of 500 Å poresize column is the key to baseline separation of Ag(I) from ∼ 1 nm AgNPs. The feasibility of the proposed method was demonstrated in speciation analysis of dissoluble Ag(I) and NAg in antibacterial products and environmental waters, with very good chromatographic repeatability (relative standard deviations) in both peak area (<2%) and retention time (<0.6%), excellent spiked recoveries in the range of 84.7-102.7% for Ag(I) and 81.3-106.3% for NAg. Our work offers a novel approach to rapid and baseline separation of dissoluble metal ions from their nanoparticulate counterparts covering the whole range of 1-100 nm.

  15. Determination of Diffusion Coefficients and Activation Energy of Selected Organic Liquids using Reversed-Flow Gas Chromatographic Technique

    International Nuclear Information System (INIS)

    Khalisanni Khalid; Rashid Atta Khan; Sharifuddin Mohd Zain

    2012-01-01

    Evaporation of vaporize organic liquid has ecological consequences when the compounds are introduced into both freshwater and marine environments through industrial effluents, or introduced directly into the air from industrial unit processes such as bioreactors and cooling towers. In such cases, a rapid and simple method are needed to measure physicochemical properties of the organic liquids. The Reversed-Flow Gas Chromatography (RF-GC) sampling technique is an easy, fast and accurate procedure. It was used to measure the diffusion coefficients of vapors from liquid into a carrier gas and at the same time to determine the rate coefficients for the evaporation of the respective liquid. The mathematical expression describing the elution curves of the samples peaks was derived and used to calculate the respective parameters for the selected liquid pollutants selected such as methanol, ethanol, 1-propanol, 1-butanol, n-pentane, n-hexane, n-heptane and n-hexadecane, evaporating into the carrier gas of nitrogen. The values of diffusion coefficients found were compared with those calculated theoretically or reported in the literature. The values of evaporation rate were used to determine the activation energy of respective samples using Arrhenius equation. An interesting finding of this work is by using an alternative mathematical analysis based on equilibrium at the liquid-gas interphase, the comparison leads to profound agreement between theoretical values of diffusion coefficients and experimental evidence. (author)

  16. An automatic injection system for rapid radiochemistry

    International Nuclear Information System (INIS)

    Nurmia, M.J.; Kreek, S.A.; Kadkhodayan, B.; Gregorich, K.E.; Lee, D.M.; Hoffman, D.C.

    1992-01-01

    A description is given of the Automated Injection System (AIS), a pneumatically actuated device for automated collection of nuclear reaction products from a He/KCl gas jet transport system. The AIS is used with the Automated Chemical Chromatographic Element Separation System; together these two devices facilitate completely automated separation procedures with improved speed and reproducibility

  17. Rapid Analysis Procedures for Triglycerides and Fatty Acids as Pentyl and Phenethyl Esters for the Detection of Butter Adulteration Using Chromatographic Techniques

    Directory of Open Access Journals (Sweden)

    Daniele Naviglio

    2017-01-01

    Full Text Available This paper presents the development of three methods for quality control, fraud detection, and authentication of butter fat and other oils/fats using chromatographic techniques, with one method for triglycerides and two methods for fatty acids (FAs. The procedure for the analysis of triglycerides requires only dissolution of the sample in n-hexane and gas chromatography (GC analysis using a capillary column. The second method is based on the transesterification of triglycerides as pentyl esters in a single-step reaction using sodium pentanoate in pentanol. The reaction proceeds at room temperature and is similar to the potassium hydroxide-catalysed transesterification of triglycerides with methanol and even more similar to the sodium methoxide method and sodium butanoate method. The advantage of using pentyl esters includes reducing the volatility of short-chain FAs, and substantial recoveries were obtained compared with methyl ester analysis. The third method involves the transesterification of triglycerides in fat through reaction with 2-phenylethanol in a single step; 2-phenylethanol possesses a chromophore, and the phenethyl esters formed are analysed by high-performance liquid chromatography (HPLC with UV detection.

  18. Towards the development of rapid screening techniques for shale gas core properties

    Science.gov (United States)

    Cave, Mark R.; Vane, Christopher; Kemp, Simon; Harrington, Jon; Cuss, Robert

    2013-04-01

    Shale gas has been produced for many years in the U.S.A. and forms around 8% of total their natural gas production. Recent testing for gas on the Fylde Coast in Lancashire UK suggests there are potentially large reserves which could be exploited. The increasing significance of shale gas has lead to the need for deeper understanding of shale behaviour. There are many factors which govern whether a particular shale will become a shale gas resource and these include: i) Organic matter abundance, type and thermal maturity; ii) Porosity-permeability relationships and pore size distribution; iii) Brittleness and its relationship to mineralogy and rock fabric. Measurements of these properties require sophisticated and time consuming laboratory techniques (Josh et al 2012), whereas rapid screening techniques could provide timely results which could improve the efficiency and cost effectiveness of exploration. In this study, techniques which are portable and provide rapid on-site measurements (X-ray Fluorescence (XRF) and Infra-red (IR) spectroscopy) have been calibrated against standard laboratory techniques (Rock-Eval 6 analyser-Vinci Technologies) and Powder whole-rock XRD analysis was carried out using a PANalytical X'Pert Pro series diffractometer equipped with a cobalt-target tube, X'Celerator detector and operated at 45kV and 40mA, to predict properties of potential shale gas material from core material from the Bowland shale Roosecote, south Cumbria. Preliminary work showed that, amongst various mineralogical and organic matter properties of the core, regression models could be used so that the total organic carbon content could be predicted from the IR spectra with a 95 percentile confidence prediction error of 0.6% organic carbon, the free hydrocarbons could be predicted with a 95 percentile confidence prediction error of 0.6 mgHC/g rock, the bound hydrocarbons could be predicted with a 95 percentile confidence prediction error of 2.4 mgHC/g rock, mica content

  19. Gas-phase acylation of aminopropyl-silica gel in the synthesis of some chemically bonded silica materials for analytical applications

    International Nuclear Information System (INIS)

    Basiuk, Vladimir; Khil'chevskaya, E.G.

    1991-01-01

    Gas-phase acylation of aminopropyl-silica gel with aliphatic dicarboxylic (succinic, adipic and sebacic) and 4-aminobenzoic acids is proposed as a rapid and efficient one-step method for the synthesis of carboxyalkyl- and 4-aminophenylamidopropyl-silica gels, usually used as zwitterion exchangers for liquid chromatography and matrices for multi-step syntheses of silica-bound aromatic azo reagents for the sorption and chromatographic separation of metal ions. Acylation degrees of 59-90% are achieved after 0.5 h. IR spectra of the acylation products and near-UV-visible spectra for bonded aromatic azo compounds, based on 4-aminobenzamidopropyl-silica gel, are presented. Some positive and negative aspects of the gas-phase acylation are discussed. (author). 34 refs.; 2 figs.; 2 tabs

  20. Chromatographic assay of degradation products of tributyl phosphate

    International Nuclear Information System (INIS)

    Tripathi, S.C.; Ramanujam, A.; Nadkarni, M.N.; Rao, K.A.; Bandyopadhyay, C.

    1985-01-01

    Gas-liquid chromatography (GLC) and thin-layer chromatographic (TLC) procedures have been developed for the estimation of monobutyl phosphoric acid (H 2 MBP) and dibutyl phosphoric acid (HDBP) present in tributyl phosphate (TBP). Less than one microgram of H 2 MBP and HDBP is visually detected on TLC plate made of silicagel-cellulose (1:1). HDBP as separated by TLC has been quantitatively estimated in the range of 40-260 μg using an indirect spectrophotometric method. GLC method using 10 percent (W/W) XE-60 column can be effectively used for the simultaneous determination of 0.25 percent W/V H 2 MBP and HDBP present in 30 percent TBP-n-dodecane. The sensitivity may be enhanced 100 fold by careful column conditioning and judicious control of operational parameters. (author)

  1. High-performance liquid chromatographic analysis of methadone hydrochloride oral solution.

    Science.gov (United States)

    Beasley, T H; Ziegler, H W

    1977-12-01

    A direct and rapid high-performance liquid chromatographic assay for methadone hydrochloride in a flavored oral solution dosage form is described. A syrup sample, one part diluted with three parts of water, is introduced onto a column packed with octadecylsilane bonded on 10 micrometer porous silica gel (reversed phase). A formic acid-ammonium formate-buffered mobile phase is linear programmed with acetonitrile. The absorbance is monitored continuously at 280 or 254 nm, using a flow-through, UV, double-beam photometer. An aqueous methadone hydrochloride solution is used for external standardization. The relative standard deviation was not more than 1.0%. Drug recovery from a syrup base was better than 99.8%.

  2. Carbon-14 labelling of biomolecules induced by 14CO ionized gas

    International Nuclear Information System (INIS)

    Lier, J.E. van; Sanche, L.

    1979-01-01

    Ionized 14 CO gas provides a rapid method for producing 14 C-labelled biomolecules. The apparatus consists of a high vacuum system in which a small amount of 14 CO is ionized by electron impact. The resulting species drift towards a target where they interact with the molecule of interest to produce 14 C-labelled compounds. Since the reaction time is only 2 minutes, the method is particularly promising for producing tracer biomolecules with short-lived 11 C at high specific activities. The applicability of the method to various classes of compounds of biological importance, including steroids, alkaloids, prostaglandins, nucleosides, amino acids and proteins has been studied. All compounds treated gave rise to 14 C addition and degradation products. Furthermore, for some compounds, chromatographic analysis in multiple systems followed by derivatization and crystallization to constant specific activity, indicated that carbon exchange may occur to produce the labelled, but otherwise unaltered substrate in yields of the order of 10-100 mCi/mol. More conclusive proof of radiochemical identity must await production of larger quantities of material and rigorous purification including at least two different chromatographic techniques. (author)

  3. Simple gas chromatographic system for analysis of microbial respiratory gases

    Science.gov (United States)

    Carle, G. C.

    1972-01-01

    Dual column ambient temperature system, consisting of pair of capillary columns, microbead thermistor detector and micro gas-sampling valve, is used in remote life-detection equipment for space experiments. Performance outweighs advantage gained by utilizing single-column systems to reduce weight, conserve carrier gas and operate at lower power levels.

  4. Gas Chromatographic-Mass Spectrometric Analysis of Essential Oil ...

    African Journals Online (AJOL)

    Purpose: To analyze the essential oil composition of the flower of Jasminum officinale L. var. grandifloroum L. (Jasminum grandiflorum) by gas chromatography-mass spectrometry (GC-MS). Methods: The optimum GC-MS conditions used for the analysis were 250 oC inlet temperature, 150 oC MSD detector temperature, ...

  5. Chromatographic Determination of Toluene and its Metabolites in Urine for Toluene Exposure - A Review

    International Nuclear Information System (INIS)

    Mohamad Raizul Zinalibdin; Abdul Rahim Yacob; Mohd Marsin Sanagi

    2016-01-01

    The determinations of toluene and their metabolites in biological samples such as urine and blood allow the estimation of the degree of exposure to this chemical. Chromatographic methods and preliminary methods are now universally employed for this purpose. Preliminary color test methods are well established for qualitative determination of toluene and its metabolites. Mobile test kits using color test methods are a vast tool for screening urine samples but chromatographic methods are still needed for confirmation and quantitative analysis. Gas chromatography (GC) methods are well-adapted for the determination of toluene metabolite in urine, but these methods often require several pretreatment steps. Meanwhile, high performance liquid chromatography (HPLC) is becoming a powerful tool for the accurate and easy determination of toluene metabolites considering its decisive advantages for routine monitoring. Furthermore, recent development in HPLC could widen the usefulness of this method to solve the most complex analytical problems that could be encountered during the measurement. (author)

  6. Chromatographic fingerprinting through chemometric techniques for herbal slimming pills: A way of adulterant identification.

    Science.gov (United States)

    Shekari, Nafiseh; Vosough, Maryam; Tabar Heidar, Kourosh

    2018-05-01

    In the current study, gas chromatography-mass spectrometry (GC-MS) fingerprinting of herbal slimming pills assisted by chemometric methods has been presented. Deconvolution of two-way chromatographic signals of nine herbal slimming pills into pure chromatographic and spectral patterns was performed. The peak clusters were resolved using multivariate curve resolution-alternating least squares (MCR-ALS) by employing appropriate constraints. It was revealed that more useful chemical information about the composition of the slimming pills can be obtained by employing sophisticated GC-MS method coupled with proper chemometric tools yielding the extended number of identified constituents. The thorough fingerprinting of the complex mixtures proved the presence of some toxic or carcinogen components, such as toluene, furfural, furfuryl alcohol, styrene, itaconic anhydride, citraconic anhydride, trimethyl phosphate, phenol, pyrocatechol, p-propenylanisole and pyrogallol. In addition, some samples were shown to be adulterated with undeclared ingredients, including stimulants, anorexiant and laxatives such as phenolphthalein, amfepramone, caffeine and sibutramine. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. Chromatographic quality control procedures for /sup 99m/Tc-diagnostic agents

    International Nuclear Information System (INIS)

    Marinelli, M.; Pozzato, R.; Garuti, P.; Zucchini, G.L.

    1986-01-01

    The purpose of this work was to experiment simple and rapid chromatographic systems, based on paper and thin-layer techniques, to test the radiochemical purity of some common /sup 99m/Tc diagnostic agents, and select those systems able to prevent the anomalies due to oxidation and artifact production. The agents were examined under conditions which usually bring about the above mentioned anomalies, then the results were compared with those obtained under controlled conditions. Quali- and quantitative detection of the activity present on the chromatograms was carried out using the equipment available in nuclear medicine departments

  8. An improved, automated whole air sampler and gas chromatography mass spectrometry analysis system for volatile organic compounds in the atmosphere

    Science.gov (United States)

    Lerner, Brian M.; Gilman, Jessica B.; Aikin, Kenneth C.; Atlas, Elliot L.; Goldan, Paul D.; Graus, Martin; Hendershot, Roger; Isaacman-VanWertz, Gabriel A.; Koss, Abigail; Kuster, William C.; Lueb, Richard A.; McLaughlin, Richard J.; Peischl, Jeff; Sueper, Donna; Ryerson, Thomas B.; Tokarek, Travis W.; Warneke, Carsten; Yuan, Bin; de Gouw, Joost A.

    2017-01-01

    Volatile organic compounds were quantified during two aircraft-based field campaigns using highly automated, whole air samplers with expedited post-flight analysis via a new custom-built, field-deployable gas chromatography-mass spectrometry instrument. During flight, air samples were pressurized with a stainless steel bellows compressor into electropolished stainless steel canisters. The air samples were analyzed using a novel gas chromatograph system designed specifically for field use which eliminates the need for liquid nitrogen. Instead, a Stirling cooler is used for cryogenic sample pre-concentration at temperatures as low as -165 °C. The analysis system was fully automated on a 20 min cycle to allow for unattended processing of an entire flight of 72 sample canisters within 30 h, thereby reducing typical sample residence times in the canisters to less than 3 days. The new analytical system is capable of quantifying a wide suite of C2 to C10 organic compounds at part-per-trillion sensitivity. This paper describes the sampling and analysis systems, along with the data analysis procedures which include a new peak-fitting software package for rapid chromatographic data reduction. Instrument sensitivities, uncertainties and system artifacts are presented for 35 trace gas species in canister samples. Comparisons of reported mixing ratios from each field campaign with measurements from other instruments are also presented.

  9. Warping methods for spectroscopic and chromatographic signal alignment: A tutorial

    Energy Technology Data Exchange (ETDEWEB)

    Bloemberg, Tom G., E-mail: T.Bloemberg@science.ru.nl [Radboud University Nijmegen, Institute for Molecules and Materials, Heyendaalseweg 135, 6525 AJ Nijmegen (Netherlands); Radboud University Nijmegen, Education Institute for Molecular Sciences, Heyendaalseweg 135, 6525 AJ Nijmegen (Netherlands); Gerretzen, Jan; Lunshof, Anton [Radboud University Nijmegen, Institute for Molecules and Materials, Heyendaalseweg 135, 6525 AJ Nijmegen (Netherlands); Wehrens, Ron [Centre for Research and Innovation, Fondazione Edmund Mach, Via E. Mach, 1, 38010 San Michele all’Adige, TN (Italy); Buydens, Lutgarde M.C. [Radboud University Nijmegen, Institute for Molecules and Materials, Heyendaalseweg 135, 6525 AJ Nijmegen (Netherlands)

    2013-06-05

    Highlights: •The concepts of warping and alignment are introduced. •The most important warping methods are critically reviewed and explained. •Reference selection, evaluation and place of warping in preprocessing are discussed. •Some pitfalls, especially for LC–MS and similar data, are addressed. •Examples are provided, together with programming scripts to rework and extend them. -- Abstract: Warping methods are an important class of methods that can correct for misalignments in (a.o.) chemical measurements. Their use in preprocessing of chromatographic, spectroscopic and spectrometric data has grown rapidly over the last decade. This tutorial review aims to give a critical introduction to the most important warping methods, the place of warping in preprocessing and current views on the related matters of reference selection, optimization, and evaluation. Some pitfalls in warping, notably for liquid chromatography–mass spectrometry (LC–MS) data and similar, will be discussed. Examples will be given of the application of a number of freely available warping methods to a nuclear magnetic resonance (NMR) spectroscopic dataset and a chromatographic dataset. As part of the Supporting Information, we provide a number of programming scripts in Matlab and R, allowing the reader to work the extended examples in detail and to reproduce the figures in this paper.

  10. Probabilistic peak detection for first-order chromatographic data

    NARCIS (Netherlands)

    Lopatka, M.; Vivó-Truyols, G.; Sjerps, M.J.

    2014-01-01

    We present a novel algorithm for probabilistic peak detection in first-order chromatographic data. Unlike conventional methods that deliver a binary answer pertaining to the expected presence or absence of a chromatographic peak, our method calculates the probability of a point being affected by

  11. Acrylamide analysis in food by liquid chromatographic and gas chromatographic methods.

    Science.gov (United States)

    Elbashir, Abdalla A; Omar, Mei M Ali; Ibrahim, Wan Aini Wan; Schmitz, Oliver J; Aboul-Enein, Hassan Y

    2014-01-01

    Acrylamide (AA) is a compound classified as carcinogenic to humans by the International Agency for Research on Cancer. It was first discovered to be present in certain heated processed food by the Swedish National Food Administration (SNFA) and University of Stockholm in early 2002. The major pathway for AA formation in food is the Maillard reaction between reducing sugar and the amino acid asparagine at high temperature. Since the discovery of AA's presence in food, many analytical methods have been developed for determination of AA contents in different food matrices. Also, several studies have been conducted to develop extraction procedures for AA from difficult food matrices. AA is a small, highly polar molecule, which makes its extraction and analysis challenging. Many articles and reviews have been published dealing with AA in food. The aim of the review is to discuss AA formation in food, the factors affecting AA formation and removal, AA exposure assessment, AA extraction and cleanup from food samples, and analytical methods used in AA determination, such as high-performance liquid chromatography (HPLC) and gas chromatography (GC). Special attention is given to sample extraction and cleanup procedures and analytical techniques used for AA determination.

  12. Application of a 1,1,3,3-tetramethylguanidine (TMG)/MeOH-CO2 in situ derivatization procedure for the gas chromatographic characterization of the fatty acid profile in olive oil.

    Science.gov (United States)

    Saliu, F; Anzano, M; Franzetti, A

    2015-03-01

    1,1,3,3-Tetramethylguanidine (TMG), methanol and carbon dioxide were investigated as switchable polarity solvents (SPS) in the simultaneous derivatization and extraction of triacylglycerols for the gas chromatographic (GC) characterization of olive oil. Three commercial olive oils were used as test samples. Results of the developed method did not differ statistically from those provided by reference derivatization procedures. The transesterification reaction was carried out under a very mild condition, one step and in situ, and no particular matrix interferences were evidenced. The method represented the first example of the use of a switchable polarity mixture for the preparation of methyl ester derivatives of fatty acids (FAME).

  13. Rapid fuel switching from coal to natural gas through effective carbon pricing

    Science.gov (United States)

    Wilson, I. A. Grant; Staffell, Iain

    2018-05-01

    Great Britain's overall carbon emissions fell by 6% in 2016, due to cleaner electricity production. This was not due to a surge in low-carbon nuclear or renewable sources; instead it was the much-overlooked impact of fuel switching from coal to natural gas generation. This Perspective considers the enabling conditions in Great Britain and the potential for rapid fuel switching in other coal-reliant countries. We find that spare generation and fuel supply-chain capacity must already exist for fuel switching to deliver rapid carbon savings, and to avoid further high-carbon infrastructure lock-in. More important is the political will to alter the marketplace and incentivize this switch, for example, through a stable and strong carbon price. With the right incentives, fuel switching in the power sector could rapidly achieve on the order of 1 GtCO2 saving per year worldwide (3% of global emissions), buying precious time to slow the growth in cumulative carbon emissions.

  14. Rapid and Convenient Separation of Chitooligosaccharides by Ion-Exchange Chromatography

    Science.gov (United States)

    Wu, Yuxiao; Lu, Wei-Peng; Wang, Jianing; Gao, Yunhua; Guo, Yanchuan

    2017-12-01

    Pervious methods for separation of highly purified chitooligosaccharides was time-consuming and labor-intensive, which limited the large-scale production. This study developed a convenient ion-exchange chromatography using the ÄKTA™ avant 150 chromatographic system. Five fractions were automatically collected under detecting the absorption at 210 nm. The fractions were analyzed by high-performance liquid chromatography. It proved that they primarily comprised chitobiose, chitotriose, chitotetraose, chitopentaose, and chitohexaose, respectively, with chromatographic purities over 90%. The separation process was rapid, convenient and could be monitored on-line, which would be benefit for the mass production of chitooligosaccharides.

  15. Rapid and selective derivatizatin method for the nitrogen-sensitive detection of carboxylic acids in biological fluids prior to gas chromatographic analysis

    NARCIS (Netherlands)

    Lingeman, H.; Haan, H.B.P.; Hulshoff, A.

    1984-01-01

    A rapid and selective derivatization procedure is described for the pre-column labelling of carboxylic acids with a nitrogen-containing label. The carboxylic acid function is activated with 2-bromo-1-methylpyridinium iodide and the activated carboxylic acid function reacts with a primary or a

  16. Simple setup for gas-phase H/D exchange mass spectrometry coupled to electron transfer dissociation and ion mobility for analysis of polypeptide structure on a liquid chromatographic time scale.

    Science.gov (United States)

    Mistarz, Ulrik H; Brown, Jeffery M; Haselmann, Kim F; Rand, Kasper D

    2014-12-02

    Gas-phase hydrogen/deuterium exchange (HDX) is a fast and sensitive, yet unharnessed analytical approach for providing information on the structural properties of biomolecules, in a complementary manner to mass analysis. Here, we describe a simple setup for ND3-mediated millisecond gas-phase HDX inside a mass spectrometer immediately after ESI (gas-phase HDX-MS) and show utility for studying the primary and higher-order structure of peptides and proteins. HDX was achieved by passing N2-gas through a container filled with aqueous deuterated ammonia reagent (ND3/D2O) and admitting the saturated gas immediately upstream or downstream of the primary skimmer cone. The approach was implemented on three commercially available mass spectrometers and required no or minor fully reversible reconfiguration of gas-inlets of the ion source. Results from gas-phase HDX-MS of peptides using the aqueous ND3/D2O as HDX reagent indicate that labeling is facilitated exclusively through gaseous ND3, yielding similar results to the infusion of purified ND3-gas, while circumventing the complications associated with the use of hazardous purified gases. Comparison of the solution-phase- and gas-phase deuterium uptake of Leu-Enkephalin and Glu-Fibrinopeptide B, confirmed that this gas-phase HDX-MS approach allows for labeling of sites (heteroatom-bound non-amide hydrogens located on side-chains, N-terminus and C-terminus) not accessed by classical solution-phase HDX-MS. The simple setup is compatible with liquid chromatography and a chip-based automated nanoESI interface, allowing for online gas-phase HDX-MS analysis of peptides and proteins separated on a liquid chromatographic time scale at increased throughput. Furthermore, online gas-phase HDX-MS could be performed in tandem with ion mobility separation or electron transfer dissociation, thus enabling multiple orthogonal analyses of the structural properties of peptides and proteins in a single automated LC-MS workflow.

  17. Waste Gas And Particulate Control Measures For Laser Cutters In The Automotive Cloth Industry

    Science.gov (United States)

    Ball, R. D.; Kulik, B. F.; Stoncel, R. J.; Tan, S. L.

    1986-11-01

    Demands for greater flexibility and accuracy in the manufacture of automobile trim parts has made single-ply laser cutting an attractive proposition. Lasers are able to cut a large variety of cloth types, from vinyls to velours. Unlike mechanically cut parts, which in the case of velours produce rough edges and dust problems, laster cutting of parts produces smooth edges, fumes and fine particulate. A detailed study of the nature of the laser effluent from a cross section of typical synthetic cloth found in an automotive trim plant was undertaken. Most samples were cut by a fast axial flow, 500 Watt, continuous wave CO2 laser. A 254 mm (10-inch) focussing optics package was used. The width of the kerf varied with the material, and values were determined at between 0.2 and 0.7 mm. Particle size distribution analysis and rates of particulate emission for each cloth were determined. Gases were collected in gas sample bags and analyzed using Fourier transform infrared analysis. Low boiling point organics were collected on activated charcoal tubes, identified on a gas chromatograph mass spectrometer, and quantified on a gas chromatograph. Inorganic contaminants were collected on filter paper and analysed on an inductively coupled plasma atomic emission spectrometer. A number of different effluent control systems were evaluated. Due to the very fine and sticky nature of the particulate, filters capable of removing particulate sizes in the 10 μm or lower range, tend to clog rapidly. Laboratory scale models of wet scrubbers, and electrostatic precipitators were built and tested. The most effective dust and effluent gas control was given by a wet electrostatic precipitator. This system, in conjunction with a scrubber, should maintain emission levels within environmental standards.

  18. Effect of chromatographic separation on ASP system interface tension and the countermeasures

    Directory of Open Access Journals (Sweden)

    Jiawei REN

    2016-06-01

    Full Text Available Because of the existing chromatographic separation phenomenon, ASP flooding changes original nature of the system. Therefore, in laboratory ultra-low interfacial tension ASP system is preferred for sand packs flow experiment to research on the effect of chromatographic separation on ASP system interface tension. The two parameters of "breakthrough time" and "output difference" are used to describe the degree of chromatographic separation, and the produced fluid interfacial tensions at the outlet end at 120 min is measured. The research shows that there exists chromatographic separation between three chemicals of ASP system, with first polymer breakthrough and finally surfactant breakthrough; there is most serious chromatographic separation between surfactant and polymer, while minimum chromatographic separation between alkali and polymer; chromatographic separation makes ASP interfacial tension increase from 10-3 magnitude to 10-2 magnitude, affecting flooding effect of ASP system. Thus, reducing the loss of surfactant in the formation will be the main measure to reduce the degree of chromatographic separation. Using sophorolipid as sacrificial agent to replace part of the surfactant injected into formation before ASP system can effectively reduce the impact of chromatography separation and more effectively improve the ultimate recovery ratio.

  19. Chromatographic Techniques for Rare Earth Elements Analysis

    Science.gov (United States)

    Chen, Beibei; He, Man; Zhang, Huashan; Jiang, Zucheng; Hu, Bin

    2017-04-01

    The present capability of rare earth element (REE) analysis has been achieved by the development of two instrumental techniques. The efficiency of spectroscopic methods was extraordinarily improved for the detection and determination of REE traces in various materials. On the other hand, the determination of REEs very often depends on the preconcentration and separation of REEs, and chromatographic techniques are very powerful tools for the separation of REEs. By coupling with sensitive detectors, many ambitious analytical tasks can be fulfilled. Liquid chromatography is the most widely used technique. Different combinations of stationary phases and mobile phases could be used in ion exchange chromatography, ion chromatography, ion-pair reverse-phase chromatography and some other techniques. The application of gas chromatography is limited because only volatile compounds of REEs can be separated. Thin-layer and paper chromatography are techniques that cannot be directly coupled with suitable detectors, which limit their applications. For special demands, separations can be performed by capillary electrophoresis, which has very high separation efficiency.

  20. Determination of microstickies in recycled whitewater by headspace gas chromatography.

    Science.gov (United States)

    Chai, X-S; Samp, J C; Yang, Q F; Song, H N; Zhang, D C; Zhu, J Y

    2006-03-03

    This study proposed a novel headspace gas chromatographic (HS-GC) method for determination of adhesive contaminants (microstickies) in recycled whitewater, a fiber containing process stream, in the paper mill. It is based on the adsorption behavior of toluene (as a tracer) on the hydrophobic surface of microstickies, which affects the apparent vapor-liquid equilibration partitioning of toluene. It was found that the equilibrium concentration of toluene in the vapor phase is inversely proportional to the apparent effective surface area of microstickies that remain in the corresponding solution. Thus, the amount of microsticky materials in the recycled whitewater can be quantified by HS-GC via indirect measurement of the toluene content in the vapor phase of the sample without any pretreatment. The presented method is simple, rapid and automated.

  1. Reverse-Phase High-Performance Liquid Chromatographic Separation of Methylated and Non-Methylated Nucleic Acid Bases

    OpenAIRE

    Madyastha, Prema; Rao, Pratima; Deobagkar, DN; Madyastha, KM

    1983-01-01

    A high-performance liquid chromatographic sepration method is described for the detection of 5-methylcytosine and 6-methyladenine in nucleic acid ext. The bases were sepd. on a Waters $C18 \\mu$ Bondapak column with a water: methanol acetic acid system. Effluents were monitored by UV absorption at 254 nm. The bases were estd. by peak heights which are proportional to the amts. of the individual bases. The method is rapid, sensitive, easy to perform and reproducible.

  2. Gas chromatographic determination of polycyclic aromatic hydrocarbons in water and smoked rice samples after solid-phase microextraction using multiwalled carbon nanotube loaded hollow fiber.

    Science.gov (United States)

    Matin, Amir Abbas; Biparva, Pourya; Gheshlaghi, Mohammad

    2014-12-29

    A novel solid-phase microextraction fiber was prepared based on multiwalled carbon nanotubes (MWCNTs) loaded on hollow fiber membrane pores. Stainless steel wire was used as unbreakable support. The major advantages of the proposed fiber are its (a) high reproducibility due to the uniform structure of the hollow fiber membranes, (b) high extraction capacity related to the porous structure of the hollow fiber and outstanding adsorptive characteristics of MWCNTs. The proposed fiber was applied for the microextraction of five representative polycyclic aromatic hydrocarbons (PAHs) from aqueous media (river and hubble-bubble water) and smoked rice samples followed by gas chromatographic determination. Analytical merits of the method, including high correlation coefficients [(0.9963-0.9992) and (0.9982-0.9999)] and low detection limits [(9.0-13.0ngL(-1)) and (40.0-150.0ngkg(-1))] for water and rice samples, respectively, made the proposed method suitable for the ultra-trace determination of PAHs. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Stereometabolism of ethylbenzene in man: gas chromatographic determination of urinary excreted mandelic acid enantiomers and phenylglyoxylic acid and their relation to the height of occupational exposure.

    Science.gov (United States)

    Korn, M; Gfrörer, W; Herz, R; Wodarz, I; Wodarz, R

    1992-01-01

    Ethylbenzene is an important industrial solvent and a key substance in styrene production. Ethylbenzene metabolism leads to the formation of mandelic acid, which occurs in two enantiomeric forms, and phenylglyoxylic acid. To decide which enantiomer is preferably formed, 70 urine samples of exposed workers were taken at the end of shifts and--after 3-pentyl ester derivatisation--gas chromatographically analysed. The R/S ratio of mandelic acid enantiomers in urine amounts to 19:1, which means that R-mandelic acid is a major metabolite and S-mandelic acid is one of the minor urinary metabolites of ethylbenzene in man. The R/S ratio is independent of ambient air concentration of ethylbenzene within the investigated range. Compared to an ethylbenzene monoexposure the height of total mandelic acid excretion is decreased in the case of coexposure to other aromatic solvents.

  4. Antioxidant and Antiangiogenic Properties, and Gas Chromatographic-Time of Flight Analysis of Sonchus arvensis Leaves Extracts

    International Nuclear Information System (INIS)

    Itam, A.; Shah, A. M.; Majid, A.; Ismail, Z.

    2015-01-01

    Sonchus arvensis L. (Asteraceae) is one of the medicinal herbs used in traditional medicines, in which the leaf extract was used as a diuretic, lithotriptic and antiurolithiasis agent. The leaves of S. arvensis reported contain several compounds, including a variety of flavonoids, terpenoids and sterol, even this plant also contain silica and potassium. Flavonoids are secondary metabolite compound which have ability as antioxidant. In this study, the aims are to determine of antioxidants and antiangiogenic properties, and phytoconstituents quantitative of aqueous and methanol extracts of S. arvensis leaves. The antioxidant properties were studied using 1,1-Diphenyl-2-picrylhydrazyl (DPPH) free radical, xanthine oxidase and beta-carotene-linoleate models system. Furthermore, the antiangiogenic property was evaluated using ex vivo rat aorta ring assay. Quantitative determination of extracts phytoconstituents were carried out by using Gas Chromatographic-Time of Flight (GC-TOF) mass spectrophotometric methods. The results showed that the aqueous and methanol extracts have ability as antioxidant which is antioxidant activities of aqueous extracts on DPPH radical and inhibition of xanthine oxidase activity are higher than that of methanol extracts. Meanwhile antioxidant activity using beta-carotene-linoleate model system of S. arvensis aqueous extract is lower than that of methanol extracts. Nevertheless, the differences of these antioxidant activities are not significant. Antiangiogenic property of aqueous extract is also higher than that of methanol extract which is measured at 100 meu g mL/sup -1/ of extracts. This indicates that there is correlation between antioxidant activity and antiangigenic property, exhibiting that this plant possesses the potential to prevent or cure the diseases that related to angiogenesis such as cancer. (author)

  5. Pressure disequilibria induced by rapid valve closure in noble gas extraction lines

    Science.gov (United States)

    Morgan, Leah; Davidheiser-Kroll, Brett

    2015-01-01

    Pressure disequilibria during rapid valve closures can affect calculated molar quantities for a range of gas abundance measurements (e.g., K-Ar geochronology, (U-Th)/He geochronology, noble gas cosmogenic chronology). Modeling indicates this effect in a system with a 10 L reservoir reaches a bias of 1% before 1000 pipette aliquants have been removed from the system, and a bias of 10% before 10,000 aliquants. Herein we explore the causes and effects of this problem, which is the result of volume changes during valve closure. We also present a solution in the form of an electropneumatic pressure regulator that can precisely control valve motion. This solution reduces the effect to ∼0.3% even after 10,000 aliquants have been removed from a 10 L reservoir.

  6. Pressure disequilibria induced by rapid valve closure in noble gas extraction lines

    Science.gov (United States)

    Morgan, Leah E.; Davidheiser-Kroll, Brett

    2015-06-01

    Pressure disequilibria during rapid valve closures can affect calculated molar quantities for a range of gas abundance measurements (e.g., K-Ar geochronology, (U-Th)/He geochronology, noble gas cosmogenic chronology). Modeling indicates this effect in a system with a 10 L reservoir reaches a bias of 1% before 1000 pipette aliquants have been removed from the system, and a bias of 10% before 10,000 aliquants. Herein we explore the causes and effects of this problem, which is the result of volume changes during valve closure. We also present a solution in the form of an electropneumatic pressure regulator that can precisely control valve motion. This solution reduces the effect to ˜0.3% even after 10,000 aliquants have been removed from a 10 L reservoir.

  7. Large-volume constant-concentration sampling technique coupling with surface-enhanced Raman spectroscopy for rapid on-site gas analysis

    Science.gov (United States)

    Zhang, Zhuomin; Zhan, Yisen; Huang, Yichun; Li, Gongke

    2017-08-01

    In this work, a portable large-volume constant-concentration (LVCC) sampling technique coupling with surface-enhanced Raman spectroscopy (SERS) was developed for the rapid on-site gas analysis based on suitable derivatization methods. LVCC sampling technique mainly consisted of a specially designed sampling cell including the rigid sample container and flexible sampling bag, and an absorption-derivatization module with a portable pump and a gas flowmeter. LVCC sampling technique allowed large, alterable and well-controlled sampling volume, which kept the concentration of gas target in headspace phase constant during the entire sampling process and made the sampling result more representative. Moreover, absorption and derivatization of gas target during LVCC sampling process were efficiently merged in one step using bromine-thiourea and OPA-NH4+ strategy for ethylene and SO2 respectively, which made LVCC sampling technique conveniently adapted to consequent SERS analysis. Finally, a new LVCC sampling-SERS method was developed and successfully applied for rapid analysis of trace ethylene and SO2 from fruits. It was satisfied that trace ethylene and SO2 from real fruit samples could be actually and accurately quantified by this method. The minor concentration fluctuations of ethylene and SO2 during the entire LVCC sampling process were proved to be samples were achieved in range of 95.0-101% and 97.0-104% respectively. It is expected that portable LVCC sampling technique would pave the way for rapid on-site analysis of accurate concentrations of trace gas targets from real samples by SERS.

  8. Interlaboratory tests to identify irradiation treatment of various foods via gas chromatographic detection of hydrocarbons, ESR spectroscopy and TL analysis

    Energy Technology Data Exchange (ETDEWEB)

    Schreiber, G.A.; Helle, N.; Schulzki, G.; Linke, B.; Spiegelberg, A.; Mager, M.; Boegl, K.W. [BgVV - Federal Inst. for Health Protection of Consumers and Veterinary Medicine, Berlin (Germany)

    1996-12-31

    The gas chromatographic (GC) analysis of radiation-induced volatile hydrocarbons (HC) and 2-alkylcyclobutanones, the ESR spectroscopic detection of radiation-specific radicals and the thermoluminescence (TL) analysis of silicate mineral are the most important methods for identification of irradiated foods. After successful performance in interlaboratory studies on meat products, fish, spices, herbs and shells of nuts, all or some of these methods have been approved by national authorities in Germany and the United Kingdom. Recently, draft European Standards have been elaborated for approval by member states of the European Committee for Standardization (CEN). Several research laboratories have shown that these methods can be applied to various foods not yet tested in collaborative studies. However, for an effective application in food control it is necessary to prove their suitability in interlaboratory studies. Therefore, in 1993/94, various interlaboratory tests were organised by the BgVV. In an ESR spectroscopic test, shrimps and paprika powder were examined. Shrimps were also the subject of examination in a TL test. Finally, GC detection of radiation-induced hydrocarbons in the fat fraction of foods was used in another test to identify irradiated Camembert, avocado, papaya and mango. In the following paper, results of the interlaboratory tests are summarised. Detailed reports are published by this institute. (author).

  9. Interlaboratory tests to identify irradiation treatment of various foods via gas chromatographic detection of hydrocarbons, ESR spectroscopy and TL analysis

    International Nuclear Information System (INIS)

    Schreiber, G.A.; Helle, N.; Schulzki, G.; Linke, B.; Spiegelberg, A.; Mager, M.; Boegl, K.W.

    1996-01-01

    The gas chromatographic (GC) analysis of radiation-induced volatile hydrocarbons (HC) and 2-alkylcyclobutanones, the ESR spectroscopic detection of radiation-specific radicals and the thermoluminescence (TL) analysis of silicate mineral are the most important methods for identification of irradiated foods. After successful performance in interlaboratory studies on meat products, fish, spices, herbs and shells of nuts, all or some of these methods have been approved by national authorities in Germany and the United Kingdom. Recently, draft European Standards have been elaborated for approval by member states of the European Committee for Standardization (CEN). Several research laboratories have shown that these methods can be applied to various foods not yet tested in collaborative studies. However, for an effective application in food control it is necessary to prove their suitability in interlaboratory studies. Therefore, in 1993/94, various interlaboratory tests were organised by the BgVV. In an ESR spectroscopic test, shrimps and paprika powder were examined. Shrimps were also the subject of examination in a TL test. Finally, GC detection of radiation-induced hydrocarbons in the fat fraction of foods was used in another test to identify irradiated Camembert, avocado, papaya and mango. In the following paper, results of the interlaboratory tests are summarised. Detailed reports are published by this institute. (author)

  10. TBP degradation products. Separation and gas-chromatographic determination

    International Nuclear Information System (INIS)

    Kuada, T.A.; Alem, C.M.; Matsuda, H.T.; Araujo, B.F. de; Araujo, J.A de.

    1991-11-01

    A separation method for di butylphosphate, mono butylphosphate and phosphoric acid as degradation products in organic and aqueous streams of the process containing variable amounts of actinides and fission products is described. The products were separated by extraction and after methylation the final determination was carried out by gas chromatography. TPP was used as internal standard and 5 to 500 mg/L concentration range was determined with 1 to 10% deviation depending on the concentration of organo phosphates. (author)

  11. [Evaluation of a new blood gas analysis system: RapidPoint 500(®)].

    Science.gov (United States)

    Nicolas, Thierry; Cabrolier, Nadège; Bardonnet, Karine; Davani, Siamak

    2013-01-01

    We present here evaluation of a new blood gas analysis system, RapidPoint 500(®) (Siemens Healthcare Diagnostics). The aim of this research was to compare the ergonomics and analytical performances of this analyser with those of the RapidLab 1265 for the following parameters: pH, partial oxygen pressure, partial carbon dioxide pressure, sodium, potassium, ionized calcium, lactate and the CO-oximetry parameters: hemoglobin, oxyhemoglobin, carboxyhemoglobin, methemoglobin, reduced hemoglobin, neonatal bilirubin; as well as with the Dimension Vista 500 results for chloride and glucose. The Valtec protocol, recommended by the French Society of Clinical Biology (SFBC), was used to analyze the study results. The experiment was carried out over a period of one month in the Department of medical biochemistry. One hundred sixty five samples from adult patients admitted to the ER or hospitalized in intensive care were tested. The RapidPoint 500(®) was highly satisfactory from an ergonomic point of view. Intra-and inter- assay coefficients of variation (CV) with the three control levels were below those recommended by the SFBC for all parameters, and the comparative study gave coefficients of determination higher than 0.91. Taken together, the RapidPoint 500(®) appears fully satisfactory in terms of ergonomics and analytical performance.

  12. Chromatographic methods of the measurements of the chloride compounds in troposphere and stratosphere

    International Nuclear Information System (INIS)

    Lasa, J.; Rosiek, J.

    1992-01-01

    The paper contains a description of various chromatographic techniques used for the analysis of the tropospheric techniques used for the analysis of the tropospheric and stratospheric halogenated compounds. The types of the column packings used for separation of halogenated compounds are described. Model chromatograms illustrating the separation of halogenated compounds are presented. The methods of the air sampling and injection for the packed and capillary columns were described. The methods of the preparation of gas calibration mixtures are presented. Operational conditions for electron capture detector used by the authors of quoted paper are also given. (author). 66 refs, 29 figs, 13 tabs

  13. The development of a high performance liquid chromatograph with a sensitive on-stream radioactivity monitor for the analysis of 3H- and 14C-labelled gibberellins

    International Nuclear Information System (INIS)

    Reeve, D.R.; Yokota, T.; Nash, L.; Crozier, A.

    1976-01-01

    The development of a high performance liquid chromatograph for the separation of gibberellins is described. The system combines high efficiency, peak capacity, and sample capacity with rapid speed of analysis. In addition, the construction details of a sensitive on-stream radioactivity monitor are outlined. The overall versatility of the chromatograph has been demonstrated by the separation of a range of 3 H- and 14 C-labelled gibberellins and gibberellin precursors. The system also has considerable potential for the analysis of abscisic acid and acidic and neutral indoles. (author)

  14. Chemometric approach for development, optimization, and validation of different chromatographic methods for separation of opium alkaloids.

    Science.gov (United States)

    Acevska, J; Stefkov, G; Petkovska, R; Kulevanova, S; Dimitrovska, A

    2012-05-01

    The excessive and continuously growing interest in the simultaneous determination of poppy alkaloids imposes the development and optimization of convenient high-throughput methods for the assessment of the qualitative and quantitative profile of alkaloids in poppy straw. Systematic optimization of two chromatographic methods (gas chromatography (GC)/flame ionization detector (FID)/mass spectrometry (MS) and reversed-phase (RP)-high-performance liquid chromatography (HPLC)/diode array detector (DAD)) for the separation of alkaloids from Papaver somniferum L. (Papaveraceae) was carried out. The effects of various conditions on the predefined chromatographic descriptors were investigated using chemometrics. A full factorial linear design of experiments for determining the relationship between chromatographic conditions and the retention behavior of the analytes was used. Central composite circumscribed design was utilized for the final method optimization. By conducting the optimization of the methods in very rational manner, a great deal of excessive and unproductive laboratory research work was avoided. The developed chromatographic methods were validated and compared in line with the resolving power, sensitivity, accuracy, speed, cost, ecological aspects, and compatibility with the poppy straw extraction procedure. The separation of the opium alkaloids using the GC/FID/MS method was achieved within 10 min, avoiding any derivatization step. This method has a stronger resolving power, shorter analysis time, better cost/effectiveness factor than the RP-HPLC/DAD method and is in line with the "green trend" of the analysis. The RP-HPLC/DAD method on the other hand displayed better sensitivity for all tested alkaloids. The proposed methods provide both fast screening and an accurate content assessment of the six alkaloids in the poppy samples obtained from the selection program of Papaver strains.

  15. Technical Note: Precise quantitative measurements of total dissolved inorganic carbon from small amounts of seawater using a gas chromatographic system

    Directory of Open Access Journals (Sweden)

    T. Hansen

    2013-10-01

    Full Text Available Total dissolved inorganic carbon (CT is one of the most frequently measured parameters used to calculate the partial pressure of carbon dioxide in seawater. Its determination has become increasingly important because of the rising interest in the biological effects of ocean acidification. Coulometric and infrared detection methods are currently favored in order to precisely quantify CT. These methods however are not sufficiently validated for CT measurements of biological experiments manipulating seawater carbonate chemistry with an extended CT measurement range (~1250–2400 μmol kg–1 compared to natural open ocean seawater (~1950–2200 μmol kg−1. The requirement of total sample amounts between 0.1–1 L seawater in the coulometric- and infrared detection methods potentially exclude their use for experiments working with much smaller volumes. Additionally, precise CT analytics become difficult with high amounts of biomass (e.g., phytoplankton cultures or even impossible in the presence of planktonic calcifiers without sample pre-filtration. Filtration however, can alter CT concentration through gas exchange induced by high pressure. Addressing these problems, we present precise quantification of CT using a small, basic and inexpensive gas chromatograph as a CT analyzer. Our technique is able to provide a repeatability of ±3.1 μmol kg−1, given by the pooled standard deviation over a CT range typically applied in acidification experiments. 200 μL of sample is required to perform the actual CT measurement. The total sample amount needed is 12 mL. Moreover, we show that sample filtration is applicable with only minor alteration of the CT. The method is simple, reliable and with low cumulative material costs. Hence, it is potentially attractive for all researchers experimentally manipulating the seawater carbonate system.

  16. Isotope Ratio Monitoring Gas Chromatography Mass Spectrometry (IRM-GCMS)

    International Nuclear Information System (INIS)

    Freeman, K.H.; Ricci, S.A.; Studley, A.; Hayes, J.M.

    1989-01-01

    On Earth, the C-13 content of organic compounds is depleted by roughly 13 to 23 permil from atmospheric carbon dioxide. This difference is largely due to isotope effects associated with the fixation of inorganic carbon by photosynthetic organisms. If life once existed on Mars, then it is reasonable to expect to observe a similar fractionation. Although the strongly oxidizing conditions on the surface of Mars make preservation of ancient organic material unlikely, carbon-isotope evidence for the existence of life on Mars may still be preserved. Carbon depleted in C-13 could be preserved either in organic compounds within buried sediments, or in carbonate minerals produced by the oxidation of organic material. A technique is introduced for rapid and precise measurement of the C-13 contents of individual organic compounds. A gas chromatograph is coupled to an isotope-ratio mass spectrometer through a combustion interface, enabling on-line isotopic analysis of isolated compounds. The isotope ratios are determined by integration of ion currents over the course of each chromatographic peak. Software incorporates automatic peak determination, corrections for background, and deconvolution of overlapped peaks. Overall performance of the instrument was evaluated by the analysis of a mixture of high purity n-alkanes of know isotopic composition. Isotopic values measured via IRM-GCMS averaged withing 0.55 permil of their conventionally measured values

  17. Rapid and automated determination of plutonium and neptunium in environmental samples

    International Nuclear Information System (INIS)

    Qiao, J.

    2011-03-01

    This thesis presents improved analytical methods for rapid and automated determination of plutonium and neptunium in environmental samples using sequential injection (SI) based chromatography and inductively coupled plasma mass spectrometry (ICP-MS). The progress of methodology development in this work consists of 5 subjects stated as follows: 1) Development and optimization of an SI-anion exchange chromatographic method for rapid determination of plutonium in environmental samples in combination of inductively coupled plasma mass spectrometry detection (Paper II); (2) Methodology development and optimization for rapid determination of plutonium in environmental samples using SI-extraction chromatography prior to inductively coupled plasma mass spectrometry (Paper III); (3) Development of an SI-chromatographic method for simultaneous determination of plutonium and neptunium in environmental samples (Paper IV); (4) Investigation of the suitability and applicability of 242 Pu as a tracer for rapid neptunium determination using anion exchange chromatography in an SI-network coupled with inductively coupled plasma mass spectrometry (Paper V); (5) Exploration of macro-porous anion exchange chromatography for rapid and simultaneous determination of plutonium and neptunium within an SI system (Paper VI). The results demonstrate that the developed methods in this study are reliable and efficient for accurate assays of trace levels of plutonium and neptunium as demanded in different situations including environmental risk monitoring and assessment, emergency preparedness and surveillance of contaminated areas. (Author)

  18. Rapid and automated determination of plutonium and neptunium in environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Qiao, J.

    2011-03-15

    This thesis presents improved analytical methods for rapid and automated determination of plutonium and neptunium in environmental samples using sequential injection (SI) based chromatography and inductively coupled plasma mass spectrometry (ICP-MS). The progress of methodology development in this work consists of 5 subjects stated as follows: 1) Development and optimization of an SI-anion exchange chromatographic method for rapid determination of plutonium in environmental samples in combination of inductively coupled plasma mass spectrometry detection (Paper II); (2) Methodology development and optimization for rapid determination of plutonium in environmental samples using SI-extraction chromatography prior to inductively coupled plasma mass spectrometry (Paper III); (3) Development of an SI-chromatographic method for simultaneous determination of plutonium and neptunium in environmental samples (Paper IV); (4) Investigation of the suitability and applicability of 242Pu as a tracer for rapid neptunium determination using anion exchange chromatography in an SI-network coupled with inductively coupled plasma mass spectrometry (Paper V); (5) Exploration of macro-porous anion exchange chromatography for rapid and simultaneous determination of plutonium and neptunium within an SI system (Paper VI). The results demonstrate that the developed methods in this study are reliable and efficient for accurate assays of trace levels of plutonium and neptunium as demanded in different situations including environmental risk monitoring and assessment, emergency preparedness and surveillance of contaminated areas. (Author)

  19. XII All-Russian conference on gas chromatography. Program. Summary of reports

    International Nuclear Information System (INIS)

    2002-01-01

    Program and summary of reports of the XII All-Russian conference on gas chromatography are performed. The conference took place in Samara, 10-14 June, 2002. Reports on physicochemical regularities of gas chromatography, application of chromatographic methods in atomic energetics are included in the program of the conference. Part of the reports are deleted to the analytical application of the gas chromatography. Adsorbents for the gas chromatography, complex methods, mathematic methods in chromatography, ecological aspects of the gas chromatography [ru

  20. Liquid chromatographic determination with fluorescence detection of B6 vitamers and riboflavin in milk and pharmaceuticals

    International Nuclear Information System (INIS)

    Gatti, R.; Gioia, M.G.

    2005-01-01

    A simple, reliable and selective high performance liquid chromatographic method with fluorescence detection at different programmed wavelengths has been developed for the simultaneous analysis of B 6 vitamers (pyridoxal 5'-phosphate, 4-pyridoxic acid, pyridoxal, pyridoxine and pyridoxamine) and Vitamin B 2 in commercial vitaminized milk and in woman milk. The chromatographic separations were performed on a reversed phase octyl column by using a mobile phase consisting of sodium pentanesulfonate in 1% acetic acid-methanol-tetrahydrofuran under gradient elution conditions. The fluorescence intensity of pyridoxal 5'-phosphate was enhanced by post-column photochemical conversion, giving significantly different fluorescence spectra by a on-line photoreactor switched OFF and ON under irradiation at 254 nm. In addition, a simple and rapid method in isocratic conditions without the need of photochemical conversion was proposed for the analysis of Vitamin B 6 and Vitamin B 2 in pharmaceuticals. Linearity, precision, recovery, selectivity and sensitivity were found satisfactory for each analysed compound. Quantitation limits ranged from 26 to 240 fmol

  1. Comparison of radioimmunoassay and gas chromatographic mass spectrometric assay for d-amphetamine

    International Nuclear Information System (INIS)

    Powers, K.H.; Ebert, M.H.

    1979-01-01

    Quantification of low levels of psychotropic drugs (10 -7 to 10 -9 g ml -1 ) in small volumes of plasma requires sensitive and accurate methods. Validation of these methods is best achieved by comparing results obtained using several techniques. In this study, amphetamine levels in plasma were measured using gas chromatography mass spectrometry and radioimmunoassay. Correlation of the results obtained by the two methods was found to be positive and high (R = 0.9822). The average coefficient of variation between assays for gas chromatography mass spectrometry was 5.8% and for radioimmunoassay was 12.3%, while the average coefficient of variation within assays for gas chromatography mass spectrometry was 4.9% and for radioimmunoassay 6.9%. Although gas chromatography mass spectrometry was 1.9 times more sensitive than radioimmunoassay, for most purposes, the convenience of the radioimmunoassay method outweighs the technical superiority of gas chromatography mass spectrometry. (author)

  2. Gas Chromatic Mass Spectrometer

    Science.gov (United States)

    Wey, Chowen

    1995-01-01

    Gas chromatograph/mass spectrometer (GC/MS) used to measure and identify combustion species present in trace concentration. Advanced extractive diagnostic method measures to parts per billion (PPB), as well as differentiates between different types of hydrocarbons. Applicable for petrochemical, waste incinerator, diesel transporation, and electric utility companies in accurately monitoring types of hydrocarbon emissions generated by fuel combustion, in order to meet stricter environmental requirements. Other potential applications include manufacturing processes requiring precise detection of toxic gaseous chemicals, biomedical applications requiring precise identification of accumulative gaseous species, and gas utility operations requiring high-sensitivity leak detection.

  3. Advanced hyphenated chromatographic-mass spectrometry in mycotoxin determination: current status and prospects.

    Science.gov (United States)

    Li, Peiwu; Zhang, Zhaowei; Hu, Xiaofeng; Zhang, Qi

    2013-01-01

    Mass spectrometric techniques are essential for advanced research in food safety and environmental monitoring. These fields are important for securing the health of humans and animals, and for ensuring environmental security. Mycotoxins, toxic secondary metabolites of filamentous fungi, are major contaminants of agricultural products, food and feed, biological samples, and the environment as a whole. Mycotoxins can cause cancers, nephritic and hepatic diseases, various hemorrhagic syndromes, and immune and neurological disorders. Mycotoxin-contaminated food and feed can provoke trade conflicts, resulting in massive economic losses. Risk assessment of mycotoxin contamination for humans and animals generally depends on clear identification and reliable quantitation in diversified matrices. Pioneering work on mycotoxin quantitation using mass spectrometry (MS) was performed in the early 1970s. Now, unambiguous confirmation and quantitation of mycotoxins can be readily achieved with a variety hyphenated techniques that combine chromatographic separation with MS, including liquid chromatography (LC) or gas chromatography (GC). With the advent of atmospheric pressure ionization, LC-MS has become a routine technique. Recently, the co-occurrence of multiple mycotoxins in the same sample has drawn an increasing amount of attention. Thus, modern analyses must be able to detect and quantitate multiple mycotoxins in a single run. Improvements in tandem MS techniques have been made to achieve this purpose. This review describes the advanced research that has been done regarding mycotoxin determination using hyphenated chromatographic-MS techniques, but is not a full-circle survey of all the literature published on this topic. The present work provides an overview of the various hyphenated chromatographic-MS-based strategies that have been applied to mycotoxin analysis, with a focus on recent developments. The use of chromatographic-MS to measure levels of mycotoxins, including

  4. High-pressure liquid chromatographic analysis of pramoxine hydrochloride in high lipoid aerosol foam dosage form.

    Science.gov (United States)

    Weinberger, R; Mann, B; Posluszny, J

    1980-04-01

    A rapid and quantitative method for the determination of pramoxine hydrochloride by high-pressure liquid chromatography is presented. The drug is extracted as the salt from a preparation with a high lipoid composition by partitioning it to the aqueous phase of an ether-methanol-water-acetic acid system. The extract is chromatographed on an octadecylsilane bonded packing with a methanol-water-acetic acid-methanesulfonic acid mobile phase. The time required for each separation is approximately 6 min. Analytical recoveries of 100.4 +/- 1.5% were obtained.

  5. Gas industry construction expenditures to grow rapidly

    International Nuclear Information System (INIS)

    Quarles, W.R.

    1991-01-01

    Between 1991 and 1993, the natural gas industry will invest $28.297 billion to install additional facilities for natural gas production and storage, transmission, underground storage, gas distribution and for other general expenditures, estimates the American Gas Association as shown in the 1990 Gas Facts. This is a 38% investment increase from the forecasts in the 1989 Gas Facts. This issue forecasts investments of $13.303 billion for 1991 and $18.396 billion for 1992. This issue does not include investments for 1993. In 1989, (the last figures released) the gas industry invested $7,341 billion for new transmission lines, distribution mains, underground storage, production and storage and general facilities. Included in the 1989 expenditures are: $3.980 billion in distribution facilities; $2.081 billion in gas transmission systems and $159 million in underground storage facilities. Investment in new distribution facilities in 1991 and $4.550 billion in 1993. This is a steady increase for these three years. Investments in natural gas transmission facilities show a steady increase also. In 1991, pipe line operating companies will invest $9.391 billion for new facilities, $9.005 in 1992 and $9.901 billion in 1993

  6. MEMS-Based Micro Gas Chromatography: Design, Fabrication and Characterization

    OpenAIRE

    Zareian-Jahromi, Mohammad Amin

    2009-01-01

    This work is focused on the design, fabrication and characterization of high performance MEMS-based micro gas chromatography columns having wide range of applications in the pharmaceutical industry, environmental monitoring, petroleum distillation, clinical chemistry, and food processing. The first part of this work describes different approaches to achieve high-performance microfabricated silicon-glass separation columns for micro gas chromatographic (µGC) systems. The capillary width effec...

  7. Chromatographic separation of radioactive noble gases from xenon

    Science.gov (United States)

    Akerib, D. S.; Araújo, H. M.; Bai, X.; Bailey, A. J.; Balajthy, J.; Beltrame, P.; Bernard, E. P.; Bernstein, A.; Biesiadzinski, T. P.; Boulton, E. M.; Bramante, R.; Cahn, S. B.; Carmona-Benitez, M. C.; Chan, C.; Chiller, A. A.; Chiller, C.; Coffey, T.; Currie, A.; Cutter, J. E.; Davison, T. J. R.; Dobi, A.; Dobson, J. E. Y.; Druszkiewicz, E.; Edwards, B. N.; Faham, C. H.; Fiorucci, S.; Gaitskell, R. J.; Gehman, V. M.; Ghag, C.; Gibson, K. R.; Gilchriese, M. G. D.; Hall, C. R.; Hanhardt, M.; Haselschwardt, S. J.; Hertel, S. A.; Hogan, D. P.; Horn, M.; Huang, D. Q.; Ignarra, C. M.; Ihm, M.; Jacobsen, R. G.; Ji, W.; Kamdin, K.; Kazkaz, K.; Khaitan, D.; Knoche, R.; Larsen, N. A.; Lee, C.; Lenardo, B. G.; Lesko, K. T.; Lindote, A.; Lopes, M. I.; Manalaysay, A.; Mannino, R. L.; Marzioni, M. F.; McKinsey, D. N.; Mei, D.-M.; Mock, J.; Moongweluwan, M.; Morad, J. A.; Murphy, A. St. J.; Nehrkorn, C.; Nelson, H. N.; Neves, F.; O'Sullivan, K.; Oliver-Mallory, K. C.; Palladino, K. J.; Pease, E. K.; Pech, K.; Phelps, P.; Reichhart, L.; Rhyne, C.; Shaw, S.; Shutt, T. A.; Silva, C.; Solovov, V. N.; Sorensen, P.; Stephenson, S.; Sumner, T. J.; Szydagis, M.; Taylor, D. J.; Taylor, W.; Tennyson, B. P.; Terman, P. A.; Tiedt, D. R.; To, W. H.; Tripathi, M.; Tvrznikova, L.; Uvarov, S.; Verbus, J. R.; Webb, R. C.; White, J. T.; Whitis, T. J.; Witherell, M. S.; Wolfs, F. L. H.; Yazdani, K.; Young, S. K.; Zhang, C.

    2018-01-01

    The Large Underground Xenon (LUX) experiment operates at the Sanford Underground Research Facility to detect nuclear recoils from the hypothetical Weakly Interacting Massive Particles (WIMPs) on a liquid xenon target. Liquid xenon typically contains trace amounts of the noble radioactive isotopes 85Kr and 39Ar that are not removed by the in situ gas purification system. The decays of these isotopes at concentrations typical of research-grade xenon would be a dominant background for a WIMP search experiment. To remove these impurities from the liquid xenon, a chromatographic separation system based on adsorption on activated charcoal was built. 400 kg of xenon was processed, reducing the average concentration of krypton from 130 ppb to 3.5 ppt as measured by a cold-trap assisted mass spectroscopy system. A 50 kg batch spiked to 0.001 g/g of krypton was processed twice and reduced to an upper limit of 0.2 ppt.

  8. Multiple chromatographic fingerprinting and its application to the quality control of herbal medicines

    International Nuclear Information System (INIS)

    Fan Xiaohui; Cheng Yiyu; Ye Zhengliang; Lin Ruichao; Qian Zhongzhi

    2006-01-01

    Recently, chromatographic fingerprinting has become one of the most powerful approaches to quality control of herbal medicines. However, the performance of reported chromatographic fingerprinting constructed by single chromatogram sometimes turns out to be inadequate for complex herbal medicines, such as multi-herb botanical drug products. In this study, multiple chromatographic fingerprinting, which consists of more than one chromatographic fingerprint and represents the whole characteristics of chemical constitutions of the complex medicine, is proposed as a potential strategy in this complicated case. As a typical example, a binary chromatographic fingerprinting of 'Danshen Dropping Pill' (DSDP), the best-sold traditional Chinese medicine in China, was developed. First, two HPLC fingerprints that, respectively, represent chemical characteristics of depsides and saponins of DSDP were developed, which were used to construct binary chromatographic fingerprints of DSDP. Moreover, the authentication and validation of the binary fingerprints were performed. Then, a data-level information fusion method was employed to capture the chemical information encoded in two chromatographic fingerprints. Based on the fusion results, the lot-to-lot consistency and frauds can be determined either using similarity measure or by chemometrics approach. The application of binary chromatographic fingerprinting to consistency assessment and frauds detection of DSDP clearly demonstrated that the proposed method was a powerful approach to quality control of complex herbal medicines

  9. Gas chromatographic-mass spectrometric analysis of di(2-ethylhexyl) phthalate and its metabolites in hepatic microsomal incubations

    Energy Technology Data Exchange (ETDEWEB)

    Pietrogrande, M.C.; Rossi, D.; Paganetto, G

    2003-03-17

    A method is reported for the determination of di(2-ethylhexyl) phthalate (DEHP) and its metabolites in in vitro metabolism studies. Gas chromatography-mass spectrometry (GC-MS) analysis allows separation of 18 by-products of DEHP metabolism. On the basis of retention time and specific mass spectra m/z values, three classes of compounds can be identified: (i) alcohols as hydrolysis product; (ii) acids produced by alcohol oxidation; (iii) compounds retaining phthalic moiety. The chromatogram can also be acquired in SIM mode at m/z 149 resulting in 13 well-separated chromatographic peaks: from retention time and mass spectra it can be inferred that the main peaks correspond to mono(2-ethylhexyl) phthalate (MEHP) and ({omega}-1)-hydroxyl-MEHP. The kinetics of DEHP metabolism was studied using an S9 Aroclor-induced liver fraction as in vitro model and following incubation assay after 20, 40, 60 and 90 min. The composition of incubation mixtures can be quantitatively evaluated from selected ion monitoring chromatograms at m/z 149: the by-product concentration increases during the incubation time, as a consequence of DEHP degradation. During the incubation test a significant conversion of DEHP into MEHP is observed: a conversion yield of 10, 13, 16 and 20% of the original DEHP is obtained after 20, 40, 60 and 90 min, respectively. The metabolic conversion of DEHP to MEHP explains the endocrine-disrupting activity of the original DEHP; moreover, it has been demonstrated that MEHP and its ({omega}-1)-oxidation metabolite induce peroxisome proliferation. This result strengthens the suggestion that the study of DEHP metabolic pathway is fundamental to better understanding its toxicological behavior.

  10. Chromatographic Separation of Vitamin E Enantiomers

    Directory of Open Access Journals (Sweden)

    Ju-Yen Fu

    2017-02-01

    Full Text Available Vitamin E is recognized as an essential vitamin since its discovery in 1922. Most vegetable oils contain a mixture of tocopherols and tocotrienols in the vitamin E composition. Structurally, tocopherols and tocotrienols share a similar chromanol ring and a side chain at the C-2 position. Owing to the three chiral centers in tocopherols, they can appear as eight different stereoisomers. Plant sources of tocopherol are naturally occurring in the form of RRR while synthetic tocopherols are usually in the form of all-racemic mixture. Similarly, with only one chiral center, natural tocotrienols occur as the R-isoform. In this review, we aim to discuss a few chromatographic methods that had been used to separate the stereoisomers of tocopherols and tocotrienols. These methods include high performance liquid chromatography, gas chromatography and combination of both. The review will focus on method development including selection of chiral columns, detection method and choice of elution solvent in the context of separation efficiency, resolution and chiral purity. The applications for separation of enantiomers in vitamin E will also be discussed especially in terms of the distinctive biological potency among the stereoisoforms.

  11. Development of a novel heavy element chemistry apparatus using the RIKEN gas-field recoil separator as a pre-separator

    International Nuclear Information System (INIS)

    Haba, H.; Morita, K.; Enomoto, S.; Morimoto, K.; Kaji, D.; Nagame, Yuichiro

    2004-01-01

    A new system was developed, that supplied the super-heavy element separated physically as the former steps to the chemical analysis devices such as a gas or liquid chromatographs. The gas jet transportation device was newly set up on the edge of existing accelerator research facilities in the Institute of Physical and Chemical Research linac building (GARIS). To conduct the chemical separation experiment of a super-heavy element of 112 in future a radioactive isotope of mercury of light homology elements was manufactured with a gas jet uniting type online multi-tracer manufacturing device. The adsorption chromatograph experiment to the gold was performed using this system. (H. Katsuta)

  12. Capillary gas-solid chromatography

    International Nuclear Information System (INIS)

    Berezkin, V.G.

    1996-01-01

    Modern state of gas adsorption chromatography in open capillary columns has been analyzed. The history of the method development and its role in gas chromatography, ways to construct open adsorptional capillary columns, foundations of the theory of retention and washing of chromatographic regions in gas adsorption capillary columns have been considered. The fields is extensively and for analyzing volatile compounds of different isotopic composition, inorganic and organic gases, volatile organic polar compounds, aqueous solutions of organic compounds. Separation of nuclear-spin isomers and isotopes of hydrogen is the first illustrative example of practical application of the adsorption capillary chromatography. It is shown that duration of protium and deuterium nuclear isomers may be reduced if the column temperature is brought to 47 K

  13. Isotope Fractionation in Methane Reactions Studied by Gas Chromatography and Liquid Scintillation

    DEFF Research Database (Denmark)

    Andersen, Bertel Lohmann; Bidoglio, G.; Leip, A.

    1997-01-01

    Determination of C-14-marked methane by gas chromatography and liquid scintillation counting is shown to be useful in studies of isotope effects. Data on the specific activity is used to separate the contributions of (CH4)-C-14, and (CH4)-C-12 to the gas-chromatographic peak area. As an application...

  14. Degradation of gas-liquid gliding arc discharge on Acid Orange II

    International Nuclear Information System (INIS)

    Yan, J.H.; Liu, Y.N.; Bo, Zh.; Li, X.D.; Cen, K.F.

    2008-01-01

    The effects of pH value, initial concentration of dye solution and temperature on the degradation efficiency of Acid Orange II (AO7) using gas-liquid gliding arc discharge were investigated. The influences of pH value and temperature on degradation efficiency were not apparent. Increasing initial solution concentration caused the decrease of degradation rate and the increase of absolute degradation quantity. Considering energy efficiency and absolute degradation quantity, the gas-liquid gliding arc discharge is fit for treating high concentration organic wastewater. A possible mineralization pathway was proposed through the analysis of intermediate products detected by gas chromatograph coupled with mass spectrophotometer (GC-MS) and ion chromatograph (IC). Hydroxyl radicals reacted with the azo linkage-bearing carbon of a hydroxy-substituted ring, leading to the cleavage of -C-N- and degradation of AO7. The solution biodegradability was significantly improved (BOD 5 /COD from 0.02 to 0.43). The toxicity of intermediate products was lower than that of the initial Acid Orange II

  15. Method and apparatus for rapid adjustment of process gas inventory in gaseous diffusion cascades

    International Nuclear Information System (INIS)

    Dyer, R.H.; Fowler, A.H.; Vanstrum, P.R.

    1977-01-01

    The invention relates to an improved method and system for making relatively large and rapid adjustments in the process gas inventory of an electrically powered gaseous diffusion cascade in order to accommodate scheduled changes in the electrical power available for cascade operation. In the preferred form of the invention, the cascade is readied for a decrease in electrical input by simultaneously withdrawing substreams of the cascade B stream into respective process-gas-freezing and storage zones while decreasing the datum-pressure inputs to the positioning systems for the cascade control valves in proportion to the weight of process gas so removed. Consequently, the control valve positions are substantially unchanged by the reduction in invention, and there is minimal disturbance of the cascade isotopic gradient. The cascade is readied for restoration of the power cut by simultaneously evaporating the solids in the freezing zones to regenerate the process gas substreams and introducing them to the cascade A stream while increasing the aforementioned datum pressure inputs in proportion to the weight of process gas so returned. In the preferred form of the system for accomplishing these operations, heat exchangers are provided for freezing, storing, and evaporating the various substreams. Preferably, the heat exchangers are connected to use existing cascade auxiliary systems as a heat sink. A common control is employed to adjust and coordinate the necessary process gas transfers and datum pressure adjustments

  16. Chromatographic air analyser microsystem for the selective and sensitive detection of atmospheric pollutants

    International Nuclear Information System (INIS)

    Sanchez, Jean-Baptiste; Lahlou, Houda; Mohsen, Yehya; Berger, Franck; Vilanova, Xavier; Correig, Xavier

    2011-01-01

    The development of industry and automotive trafic produces Volatile Organic Compounds (VOCs) whose toxicity can affect seriously human health and environment. The level of those contaminants in air must be as low as possible. In this context, there is a need for in situ systems that could monitor selectively the concentration of these compounds. The aim of this study is to demonstrate the efficiency of a system build with a pre-concentrator, a chromatographic micro-column and a tin oxide-based gas sensor for the selective and sensitive detection of atmospheric pollutants. In particular, this study is focused on the selective detection of benzene and 1,3 butadiene.

  17. Multiple chromatographic fingerprinting and its application to the quality control of herbal medicines

    Energy Technology Data Exchange (ETDEWEB)

    Fan Xiaohui [Pharmaceutical Informatics Institute, College of Pharmaceutical Sciences, Zhejiang University, Hangzhou 310027 (China); Cheng Yiyu [Pharmaceutical Informatics Institute, College of Pharmaceutical Sciences, Zhejiang University, Hangzhou 310027 (China)]. E-mail: chengyy@zju.edu.cn; Ye Zhengliang [Pharmaceutical Informatics Institute, College of Pharmaceutical Sciences, Zhejiang University, Hangzhou 310027 (China); Lin Ruichao [National Institute for the Control of Pharmaceutical and Biological Products, Beijing 100050 (China); Qian Zhongzhi [Committee of Chinese Pharmacopoeia, Beijing 100061 (China)

    2006-01-12

    Recently, chromatographic fingerprinting has become one of the most powerful approaches to quality control of herbal medicines. However, the performance of reported chromatographic fingerprinting constructed by single chromatogram sometimes turns out to be inadequate for complex herbal medicines, such as multi-herb botanical drug products. In this study, multiple chromatographic fingerprinting, which consists of more than one chromatographic fingerprint and represents the whole characteristics of chemical constitutions of the complex medicine, is proposed as a potential strategy in this complicated case. As a typical example, a binary chromatographic fingerprinting of 'Danshen Dropping Pill' (DSDP), the best-sold traditional Chinese medicine in China, was developed. First, two HPLC fingerprints that, respectively, represent chemical characteristics of depsides and saponins of DSDP were developed, which were used to construct binary chromatographic fingerprints of DSDP. Moreover, the authentication and validation of the binary fingerprints were performed. Then, a data-level information fusion method was employed to capture the chemical information encoded in two chromatographic fingerprints. Based on the fusion results, the lot-to-lot consistency and frauds can be determined either using similarity measure or by chemometrics approach. The application of binary chromatographic fingerprinting to consistency assessment and frauds detection of DSDP clearly demonstrated that the proposed method was a powerful approach to quality control of complex herbal medicines.

  18. A single gas chromatograph for accurate atmospheric mixing ratio measurements of CO2, CH4, N2O, SF6 and CO

    Directory of Open Access Journals (Sweden)

    H. A. J. Meijer

    2009-09-01

    Full Text Available We present an adapted gas chromatograph capable of measuring simultaneously and semi-continuously the atmospheric mixing ratios of the greenhouse gases CO2, CH4, N2O and SF6 and the trace gas CO with high precision and long-term stability. The novelty of our design is that all species are measured with only one device, making it a very cost-efficient system. No time lags are introduced between the measured mixing ratios. The system is designed to operate fully autonomously which makes it ideal for measurements at remote and unmanned stations. Only a small amount of sample air is needed, which makes this system also highly suitable for flask air measurements. In principle, only two reference cylinders are needed for daily operation and only one calibration per year against international WMO standards is sufficient to obtain high measurement precision and accuracy. The system described in this paper is in use since May 2006 at our atmospheric measurement site Lutjewad near Groningen, The Netherlands at 6°21´ E, 53°24´N, 1 m a.s.l. Results show the long-term stability of the system. Observed measurement precisions at our remote research station Lutjewad were: ±0.04 ppm for CO2, ±0.8 ppb for CH4, ±0.8 ppb for CO, ±0.3 ppb for N2O, and ±0.1 ppt for SF6. The ambient mixing ratios of all measured species as observed at station Lutjewad for the period of May 2007 to August 2008 are presented as well.

  19. Development of Direct Reversed-Phase High Performance liquid chromatographic method for quantitative determination of gabapentin in pharmaceutical dosage

    International Nuclear Information System (INIS)

    Hassan, W.; Zaman, B.; Rahman, S.; Rahman, A.U.; Ali, N.; Mohammadzai, I.U.

    2012-01-01

    The objective of the present work was to develop and validate a rapid analytical method for quantitative determination of Gabapentin in pharmaceutical dosage tablets and capsules. An accurate, simple, and sensitive reversed-phase high performance liquid chromatographic (HPLC) method, UV detection at 215 nm and flow rate at 1.0 ml/min has been developed. Isocratic elution was used instead of gradient elution to reduce the time and cost of serial analysis. The mobile phase was a mixture of water and methanol (HPLC grade). The retention time (Rt) of Gabapentin was 4.681 +- 0.013 minutes. Recovery, Precision, accuracy, and linearity were determined for the stated method. The calibration curve was linear and the correlation coefficient was 0.9996. There was no chromatographic interference from other excipients present in dosage form. The method was validated appropriately and successfully used for determination of Gabapentin in Pharmaceutical formulations. (author)

  20. Performance characteristics of bioassay, radioenzymatic assay, homogeneous enzyme immunoassay, and high-performance liquid chromatographic determination of serum gentamicin

    International Nuclear Information System (INIS)

    Delaney, C.J.; Opheim, K.E.; Smith, A.L.; Plorde, J.J.

    1982-01-01

    We compared the accuracy, precision, and between-method error of the microbiological assay, the radioenzymatic assay, the homogeneous enzyme immunoassay, and the high-performance liquid chromatographic assay for the quantitation of gentamicin in serum. Precision and accuracy were evaluated by reference samples prepared to contain 0.0 to 32.7 micrograms of gentamicin per ml. Correlations between the methods utilized patient sera with gentamicin concentrations ranging from 0.6 to 13.3 micrograms/ml. All methods were reliable within acceptable limits for routine clinical use; intermethod correlation coefficients exceeded 0.96. Relative to the microbiological assay, the alternative methods offer the advantage of rapid analysis. The elapsed times for acquiring data on a set of 10 specimens under routine operating conditions were 0.5 h by the enzyme immunoassay, 4 h by the radioenzymatic assay, 5 h by the high-performance liquid chromatographic assay, and 10 h by the microbiological assay

  1. Large-volume constant-concentration sampling technique coupling with surface-enhanced Raman spectroscopy for rapid on-site gas analysis.

    Science.gov (United States)

    Zhang, Zhuomin; Zhan, Yisen; Huang, Yichun; Li, Gongke

    2017-08-05

    In this work, a portable large-volume constant-concentration (LVCC) sampling technique coupling with surface-enhanced Raman spectroscopy (SERS) was developed for the rapid on-site gas analysis based on suitable derivatization methods. LVCC sampling technique mainly consisted of a specially designed sampling cell including the rigid sample container and flexible sampling bag, and an absorption-derivatization module with a portable pump and a gas flowmeter. LVCC sampling technique allowed large, alterable and well-controlled sampling volume, which kept the concentration of gas target in headspace phase constant during the entire sampling process and made the sampling result more representative. Moreover, absorption and derivatization of gas target during LVCC sampling process were efficiently merged in one step using bromine-thiourea and OPA-NH 4 + strategy for ethylene and SO 2 respectively, which made LVCC sampling technique conveniently adapted to consequent SERS analysis. Finally, a new LVCC sampling-SERS method was developed and successfully applied for rapid analysis of trace ethylene and SO 2 from fruits. It was satisfied that trace ethylene and SO 2 from real fruit samples could be actually and accurately quantified by this method. The minor concentration fluctuations of ethylene and SO 2 during the entire LVCC sampling process were proved to be gas targets from real samples by SERS. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Rapid and selective detection of acetone using hierarchical ZnO gas sensor for hazardous odor markers application

    International Nuclear Information System (INIS)

    Jia, Qianqian; Ji, Huiming; Zhang, Ying; Chen, Yalu; Sun, Xiaohong; Jin, Zhengguo

    2014-01-01

    Highlights: • ZnO spheres fabricated via solvothermal method are with (0 0 2) polar facet exposed. • Response time of ZnO sensor for detecting 100 ppm acetone is as short as 3 s. • R a /R g toward 100 ppm acetone is 33 when operated at 230 °C. • ZnO sensor exhibits good selectivity against other toxic gases and water vapor. • Porous structure and exposure of polar facet contribute to good sensing properties. - Abstract: Hierarchical nanostructured ZnO dandelion-like spheres were synthesized via solvothermal reaction at 200 °C for 4 h. The products were pure hexagonal ZnO with large exposure of (0 0 2) polar facet. Side-heating gas sensor based on hierarchical ZnO spheres was prepared to evaluate the acetone gas sensing properties. The detection limit to acetone for the ZnO sensor is 0.25 ppm. The response (R a /R g ) toward 100 ppm acetone was 33 operated at 230 °C and the response time was as short as 3 s. The sensor exhibited remarkable acetone selectivity with negligible response toward other hazardous gases and water vapor. The high proportion of electron depletion region and oxygen vacancies contributed to high gas response sensitivity. The hollow and porous structure of dandelion-like ZnO spheres facilitated the diffusion of gas molecules, leading to a rapid response speed. The largely exposed (0 0 2) polar facets could adsorb acetone gas molecules easily and efficiently, resulting in a rapid response speed and good selectivity of hierarchical ZnO spheres gas sensor at low operating temperature

  3. Immunological screening of drugs of abuse and gas chromatographic-mass spectrometric confirmation of opiates and cocaine in hair.

    Science.gov (United States)

    Segura, J; Stramesi, C; Redón, A; Ventura, M; Sanchez, C J; González, G; San, L; Montagna, M

    1999-03-05

    The work presents an analytical strategy to detect drugs of abuse in hair. It involves two sequential steps: a screening by a simple enzyme-linked immunosorbent assay (ELISA) methodology to detect opiates, cocaine and its metabolites, and benzodiacepines, followed by confirmation of opiates and cocaine metabolites in positive samples by gas chromatography coupled to mass spectrometry (GC-MS). In the same GC-MS run other drugs for substitution therapy (e.g. methadone and its main metabolite) can also be detected. After a double washing of hair samples with dichloromethane, hair specimens were cut into small pieces and 10 mg samples were incubated in 2 ml of methanol-trifluoroacetic acid (9:1) mixture, overnight at 37 degrees C. Aliquots of the extract were then evaporated, reconstituted in buffer and analysed according to the ELISA procedure. Confirmation involved solid-phase extraction of another fraction of the extract kept at -20 degrees C, derivatization with heptafluorobutyric anhydride and hexafluoroisopropanol and detection of cocaine, benzoylecgonine, ecgonine methylester, cocaethylene, morphine, codeine, 6-monoacetylmorphine, methadone and 2-ethylidene-1.5-dimethyl-3,3-diphenylpirrolidine (methadone metabolite) by selective ion monitoring after gas chromatographic separation. During the development of the method it was verified that no more than 10% of cocaine, opiates and benzodiacepines were lost when dichloromethane was used to wash real samples. The results also confirmed the increase of extractability power of TFA when it was added to methanol: the recovery for the analytes (cocaine and its metabolites and opiates) added to methanol-TFA alone was of the order of 90% except for benzoylecgonine (75%), and the recovery for the analytes added to methanol-TFA extract of drug-free hair was about 90% for all analytes except for benzoylecgonine and 6-MAM (around 70%). Regarding the stability of labile compounds, only small amounts of ecgonine methylester (2

  4. Identification of phytochemical components of aloe plantlets by gas ...

    African Journals Online (AJOL)

    MRT Pack 20 DVDs

    2013-12-04

    Dec 4, 2013 ... mented with 0.5 mgl-1 benzyl adenine + 0.5 mgl-1 α-naphthalene acetic acids into ... 5973) coupled to H.P. gas chromatograph (model 6890) equipped .... effects of Aloe vera leaf gel extract on oxidative stress in rats treated.

  5. Rapid and accurate determination of radiochemical purity of sup(99m)Tc compounds

    International Nuclear Information System (INIS)

    Tamat, S.R.

    1977-01-01

    The wide spread use of sup(99m)Tc-labelled radiopharmaceuticals and limitation of the short half-life of the isotope, is associated with an urgent need for a rapid, simple but accurate method for determining the radiochemical purity of the compound. A short paper chromatographic (KK) or thin layer chromatographic (KLT) method using 95% methanol or 0.9% saline solution as solvents, has solved the problem. With these methods, the amount of free sup(99m)Tc pertechnetate in a compound, can be determined in only a few minutes. These methods compare satisfactorily with lengtheir procedures. (author)

  6. Adsorption and gas-chromatographic properties of tungsten selenide

    International Nuclear Information System (INIS)

    Gavrilova, T.B.; Kiselev, A.V.; Roshchina, T.M.

    1988-01-01

    Method of gas chromatography was used to investigate the surface properties of a series of tungsten selenide WSe 2 samples as well as to determine the role of geometrical and electronic structure of adsorbate molecules and their orientation with respect to the surface during adsorption on WSe 2 . Thermodynamic characteristics of hydrocarbon C 6 -C 10 adsorption at surface occupation close to the zero one were determined. Correlation of the values of thermodynamic characteristics of saturated and aromatic hydrocarbon adsorption enabled to refer WSe 2 to nonspecific adsorbents. It is noted that the main role during hydrocarbon adsorption on WSe 2 is played by nonpolar basic facets, occupied by selenium atoms

  7. A micro-gas phase chromatography with a re-compression system used to measure impurities in low pressure tritiated gases

    Energy Technology Data Exchange (ETDEWEB)

    Godot, A.; Colas, S.; Hubinois, J.C. [CEA Valduc, 21 - Is-sur-Tille (France)

    2008-07-15

    The measurement of the amount of impurities in tritiated gases can be achieved by means of mass spectrometry or gas phase chromatography. A growing number of disadvantages associated to the 'life expectancy' of the mass spectrometer and its tricky maintenance (when enclosed in a gloves box) have led us to acquire a micro gas phase chromatograph. This device is based on a modular concept with the injector, the column and the detector packed in a compact unit which is easy to replace. Thanks to constant improvement in the field of capillary column, new micro chromatographs are now able to perform measurement in absence of pre-column and presence of argon instead of nitrogen as a carrier gas. Of importance, this new apparatus allow better performances (running time: 1 m 30 sec, limit of detection: {<=}10 ppm). However, in normal use, this apparatus requires 800 milli-bar in the inlet, a pressure that doesn't match with the feature of our process gas. To overcome this inconvenience, we have developed an automatic functioning system with a bellows that samples and compresses the gas to pressures compatible with the micro gas chromatograph. The apparatus and the experimental procedures will be presented as well as experimental performances (reproducibility, detection limits..) for some impurities such as nitrogen, oxygen and helium. (authors)

  8. Comparison of ultra high performance supercritical fluid chromatography, ultra high performance liquid chromatography, and gas chromatography for the separation of synthetic cathinones.

    Science.gov (United States)

    Carnes, Stephanie; O'Brien, Stacey; Szewczak, Angelica; Tremeau-Cayel, Lauriane; Rowe, Walter F; McCord, Bruce; Lurie, Ira S

    2017-09-01

    A comparison of ultra high performance supercritical fluid chromatography, ultra high performance liquid chromatography, and gas chromatography for the separation of synthetic cathinones has been conducted. Nine different mixtures of bath salts were analyzed in this study. The three different chromatographic techniques were examined using a general set of controlled synthetic cathinones as well as a variety of other synthetic cathinones that exist as positional isomers. Overall 35 different synthetic cathinones were analyzed. A variety of column types and chromatographic modes were examined for developing each separation. For the ultra high performance supercritical fluid chromatography separations, analyses were performed using a series of Torus and Trefoil columns with either ammonium formate or ammonium hydroxide as additives, and methanol, ethanol or isopropanol organic solvents as modifiers. Ultra high performance liquid chromatographic separations were performed in both reversed phase and hydrophilic interaction chromatographic modes using SPP C18 and SPP HILIC columns. Gas chromatography separations were performed using an Elite-5MS capillary column. The orthogonality of ultra high performance supercritical fluid chromatography, ultra high performance liquid chromatography, and gas chromatography was examined using principal component analysis. For the best overall separation of synthetic cathinones, the use of ultra high performance supercritical fluid chromatography in combination with gas chromatography is recommended. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. A rapid method for simultaneously determining ethanol and methanol content in wines by full evaporation headspace gas chromatography.

    Science.gov (United States)

    Zhang, Chun-Yun; Lin, Neng-Biao; Chai, Xin-Sheng; Zhong-Li; Barnes, Donald G

    2015-09-15

    This work reports on a full evaporation headspace gas chromatographic (FE HS-GC) method for simultaneously determining the ethanol (EtOH) and methanol (MeOH) content in wines. A small sample (10μL) was placed in a headspace sample vial, and a near-complete mass transfer of ethanol and methanol from the liquid sample to the vapor phase was obtained within three minutes at a temperature of 105°C, which allowed the measurement of the EtOH and MeOH content in the sample by GC. The results showed excellent precision and accuracy, as shown by the reproducibilities of 1.02% and 2.11% for EtOH and MeOH, respectively, and recoveries that ranged from 96.1% to 104% for both alcohols. The method is efficient, accurate and suitable for the determination of EtOH and MeOH in wine production and quality control. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Bubble development and fission gas release during rapid heating of 18 GWd/TeU UO2

    International Nuclear Information System (INIS)

    Small, G.J.

    1985-01-01

    Small samples (approximately 50 mg) of UO 2 irradiated to 18 GWd/TeU have been heated rapidly in an out-of-pile furnace. Ramp rates were in the range 10-80 deg. C.s -1 , peak temperatures varied from 1400 deg. C to 2500 deg. C and dwell times from one to fifteen min. The specimens were sealed in small capsules which were subsequently pierced to determine the total amount of fission gas ( 85 Kr) released during each test. Changes in the size and number of gas bubbles on grain boundaries were examined using SEM, TEM, replication and fractography techniques will be employed later. In this paper are reported the first series of gas release results and some metallography. The results are compared with related experiments and some qualitative conclusions are drawn regarding the mechanisms and kinetics of transient fission gas behaviour. (author)

  11. Analyzing chromatographic data using multilevel modeling.

    Science.gov (United States)

    Wiczling, Paweł

    2018-06-01

    It is relatively easy to collect chromatographic measurements for a large number of analytes, especially with gradient chromatographic methods coupled with mass spectrometry detection. Such data often have a hierarchical or clustered structure. For example, analytes with similar hydrophobicity and dissociation constant tend to be more alike in their retention than a randomly chosen set of analytes. Multilevel models recognize the existence of such data structures by assigning a model for each parameter, with its parameters also estimated from data. In this work, a multilevel model is proposed to describe retention time data obtained from a series of wide linear organic modifier gradients of different gradient duration and different mobile phase pH for a large set of acids and bases. The multilevel model consists of (1) the same deterministic equation describing the relationship between retention time and analyte-specific and instrument-specific parameters, (2) covariance relationships relating various physicochemical properties of the analyte to chromatographically specific parameters through quantitative structure-retention relationship based equations, and (3) stochastic components of intra-analyte and interanalyte variability. The model was implemented in Stan, which provides full Bayesian inference for continuous-variable models through Markov chain Monte Carlo methods. Graphical abstract Relationships between log k and MeOH content for acidic, basic, and neutral compounds with different log P. CI credible interval, PSA polar surface area.

  12. Comparison of multiple linear regression, partial least squares and artificial neural networks for prediction of gas chromatographic relative retention times of trimethylsilylated anabolic androgenic steroids.

    Science.gov (United States)

    Fragkaki, A G; Farmaki, E; Thomaidis, N; Tsantili-Kakoulidou, A; Angelis, Y S; Koupparis, M; Georgakopoulos, C

    2012-09-21

    The comparison among different modelling techniques, such as multiple linear regression, partial least squares and artificial neural networks, has been performed in order to construct and evaluate models for prediction of gas chromatographic relative retention times of trimethylsilylated anabolic androgenic steroids. The performance of the quantitative structure-retention relationship study, using the multiple linear regression and partial least squares techniques, has been previously conducted. In the present study, artificial neural networks models were constructed and used for the prediction of relative retention times of anabolic androgenic steroids, while their efficiency is compared with that of the models derived from the multiple linear regression and partial least squares techniques. For overall ranking of the models, a novel procedure [Trends Anal. Chem. 29 (2010) 101-109] based on sum of ranking differences was applied, which permits the best model to be selected. The suggested models are considered useful for the estimation of relative retention times of designer steroids for which no analytical data are available. Copyright © 2012 Elsevier B.V. All rights reserved.

  13. Determination of plant stanols and plant sterols in phytosterol enriched foods with a gas chromatographic-flame ionization detection method: NMKL collaborative study.

    Science.gov (United States)

    Laakso, Päivi H

    2014-01-01

    This collaborative study with nine participating laboratories was conducted to determine the total plant sterol and/or plant stanol contents in phytosterol fortified foods with a gas chromatographic method. Four practice and 12 test samples representing mainly commercially available foodstuffs were analyzed as known replicates. Twelve samples were enriched with phytosterols, whereas four samples contained only natural contents of phytosterols. The analytical procedure consisted of two alternative approaches: hot saponification method, and acid hydrolysis treatment prior to hot saponification. As a result, sterol/stanol compositions and contents in the samples were measured. The amounts of total plant sterols and total plant stanols varying from 0.005 to 8.04 g/100 g product were statistically evaluated after outliers were eliminated. The repeatability RSD (RSDr) varied from 1.34 to 17.13%. The reproducibility RSD (RSDR) ranged from 3.03 to 17.70%, with HorRat values ranging from 0.8 to 2.1. When only phytosterol enriched food test samples are considered, the RSDr ranged from 1.48 to 6.13%, the RSD, ranged from 3.03 to 7.74%, and HorRat values ranged from 0.8 to 2.1. Based on the results of this collaborative study, the study coordinator concludes the method is fit for its purpose.

  14. Mixed-mode chromatographic matrices for the resolution of transfer ribonucleic acids

    NARCIS (Netherlands)

    Bischoff, Rainer; Mclaughlin, L.W.

    1984-01-01

    Modification of approximately 65% of the amine groups of an aminopropylsilyl bonded-phase silica high-performance liquid chromatographic anion exchanger (APS-Hypersil) with organic acids containing n-alkyl moieties of different chain lengths, results in mixed mode chromatographic matrices of varying

  15. Performance of chromatographic systems to model soil-water sorption.

    Science.gov (United States)

    Hidalgo-Rodríguez, Marta; Fuguet, Elisabet; Ràfols, Clara; Rosés, Martí

    2012-08-24

    A systematic approach for evaluating the goodness of chromatographic systems to model the sorption of neutral organic compounds by soil from water is presented in this work. It is based on the examination of the three sources of error that determine the overall variance obtained when soil-water partition coefficients are correlated against chromatographic retention factors: the variance of the soil-water sorption data, the variance of the chromatographic data, and the variance attributed to the dissimilarity between the two systems. These contributions of variance are easily predicted through the characterization of the systems by the solvation parameter model. According to this method, several chromatographic systems besides the reference octanol-water partition system have been selected to test their performance in the emulation of soil-water sorption. The results from the experimental correlations agree with the predicted variances. The high-performance liquid chromatography system based on an immobilized artificial membrane and the micellar electrokinetic chromatography systems of sodium dodecylsulfate and sodium taurocholate provide the most precise correlation models. They have shown to predict well soil-water sorption coefficients of several tested herbicides. Octanol-water partitions and high-performance liquid chromatography measurements using C18 columns are less suited for the estimation of soil-water partition coefficients. Copyright © 2012 Elsevier B.V. All rights reserved.

  16. Chromatographic method of measurement of helium concentration in underground waters for dating in hydrological questions

    International Nuclear Information System (INIS)

    Najman, J.

    2008-04-01

    Research methods which use natural environmental indicators are widely applied in hydrology. Different concentrations of indicators and their isotopic components in ground waters allow to determine the genesis of waters and are valuable source of information about the water flow dynamics. One of the significant indicator is helium. The concentration of 4 He (helium) in ground water is a fine indicator in water dating in a range from a hundreds to millions of years (Aeschbach-Hertig i in., 1999; Andrews i in., 1989; Castro i in., 2000; Zuber i in., 2007). 4 He is also used for dating young waters of age about 10 years (Solomon i in., 1996). Thesis consist the description of elaborated in IFJ PAN in Krakow chromatographic measurement method of helium concentration in ground waters in aim of dating. Chapter 1 contain short introduction about ground water dating and chapter 2 description of helium property and chosen applications of helium for example in technology and earthquake predictions. Helium sources in ground waters are described in chapter 3. Helium concentration in water after infiltration (originated from atmosphere) to the ground water system depends mainly on the helium concentration coming from the equilibration with the atmosphere increased by additional concentration from '' excess air ''. With the increasing resistance time of ground water during the flow, radiogenic, non-atmospheric component of helium dissolves also in water. In chapter 4 two measurement methods of helium concentration in ground waters were introduced: mass spectrometric and gas chromatographic method. Detailed description of elaborated chromatographic measurement method of helium concentration in ground water contain chapter 5. To verify developed method the concentration of helium in ground waters from the regions of Krakow and Busko Zdroj were measured. For this waters the concentrations of helium are known from the earlier mass spectrometric measurements. The results of

  17. Properties of rapidly solidified Fe-Cr-Al ribbons for the use as automotive exhaust gas catalyst substrates

    International Nuclear Information System (INIS)

    Emmerich, K.

    1993-01-01

    Metallic honeycomb structures are used as catalyst substrates in automotive exhaust gas systems. This application requires an outstanding corrosion resistance at elevated temperatures of the substrate material. Technical improvements can be achieved by the use of rapid solidification technology for the production of the Fe-Cr-Al ribbons since the Al content can be substantially increased from about 5% Al in the conventionally rolled material to about 12% Al in the rapid solidified ribbon. As a result the lifetime of the ribbon in a higher-temperature corrosion environment is drastically increased. In addition the scale/metal adherance is improved. The impediment of recrystallization in the rapidly solidified ribbons prevents an embrittlement even in carbonizing atmospheres. (orig.)

  18. Chromatographic studies of thorium(IV) and its extraction from monazite sand

    International Nuclear Information System (INIS)

    Bandyopadhyay, Arup; Roy, Uday Sankar

    1998-01-01

    A simple, rapid and selective method has been developed for reversed phase extraction chromatographic studies of Th IV with high molecular mass monocarboxylic acid (C 15 -C 16 ), SRS-100 as a stationary phase on a column of silica gel. Quantitative extraction of Th IV has been achieved in the pH range 4.8-5.5. The extracted Th IV has been stripped with 1:1 (v/v) mixture of 0.2 M HNO 3 and 0.2 M NaNO 3 and estimated spectrophotometrically. The effect of variables as pH, stripping agents, flow rate on extraction and elution have been studied. Th IV has been separated from various commonly associated elements in binary and synthetic multicomponent mixtures. The method has been applied successfully for the extraction of thorium from monazite sand. (author)

  19. Brazilian organic sugarcane spirits: Physicochemical and chromatographic profile

    Directory of Open Access Journals (Sweden)

    Felipe Cimino Duarte

    Full Text Available ABSTRACT There has been a growing demand for products from organic agriculture for the food market. Brazil leads the production of sugarcane spirits and produces about 1.6 billion liters/year. New technologies have been sought throughout the supply chain to improve production, and organic raw material has been used in the production of sugar cane for the production of beverages. This study aimed to define the physicochemical and chromatographic profiles of eleven organic sugarcane spirits samples from various Brazilian states. The secondary components and contaminants were identified and quantified through physicochemical analyses, HPLC and gas chromatography (GC. A significant percentage of the organic sugarcane spirits samples contained concentrations of components that were above the limits required by the Ministry of Agriculture, Livestock and Provisioning (MAPA, specifically the esters (18.20%, copper and dry extract (9.10%. This contamination is caused by bad conditions employed during the production process, which are not in compliance with the good manufacturing practices determined and legislated by Brazilian law.

  20. Chromatographic methods

    International Nuclear Information System (INIS)

    Marhol, M.; Stary, J.

    1975-01-01

    The characteristics are given of chromatographic separation and the methods are listed. Methods and data on materials used in partition, adsorption, precipitation and ion exchange chromatography are listed and conditions are described under which ion partition takes place. Special attention is devoted to ion exchange chromatography where tables are given to show the course of values of the partition coefficients of different ions in dependence on the concentration of agents and the course of equilibrium sorptions on different materials in dependence on the solution pH. A theoretical analysis is given and the properties of the most widely used ion exchangers are listed. Experimental conditions and apparatus used for each type of chromatography are listed. (L.K.)

  1. Alternative chromatographic system for the quality control of lipophilic technetium-99m radiopharmaceuticals such as [99mTc(MIBI6]+

    Directory of Open Access Journals (Sweden)

    D.P. Faria

    2015-01-01

    Full Text Available Knowledge of the radiochemical purity of radiopharmaceuticals is mandatory and can be evaluated by several methods and techniques. Planar chromatography is the technique normally employed in nuclear medicine since it is simple, rapid and usually of low cost. There is no standard system for the chromatographic technique, but price, separation efficiency and short time for execution must be considered. We have studied an alternative system using common chromatographic stationary phase and alcohol or alcohol:chloroform mixtures as the mobile phase, using the lipophilic radiopharmaceutical [99mTc(MIBI6]+ as a model. Whatman 1 modified phase paper and absolute ethanol, Whatman 1 paper and methanol:chloroform (25:75, Whatman 3MM paper and ethanol:chloroform (25:75, and the more expensive ITLC-SG and 1-propanol:chloroform (10:90 were suitable systems for the direct determination of radiochemical purity of [99mTc(MIBI6]+ since impurities such as 99mTc-reduced-hydrolyzed (RH, 99mTcO4 - and [99mTc(cysteine2]- complex were completely separated from the radiopharmaceutical, which moved toward the front of chromatographic systems while impurities were retained at the origin. The time required for analysis was 4 to 15 min, which is appropriate for nuclear medicine routines.

  2. Trends in natural gas distribution and measurements

    International Nuclear Information System (INIS)

    Crone, C.F.A.

    1993-01-01

    On the occasion of the GAS EXPO 93, to be held from 13-15 October 1993 in Amsterdam, Netherlands, an overview is given of trends in the distribution of natural gas and the measuring of natural gas, as noted by experts from the energy utilities, GASTEC and Gasunie in the Netherlands. With regard to the natural gas distribution trends attention is paid to synthetic materials, the environmental effects, maintenance, underground natural gas pressure control, horizontal drilling (no-dig techniques), and other trends. With regard to natural gas metering trends brief discussions are given of the direct energy meter, the search for a new gas meter in households, telemetering, improving the accuracy of the gas meters by means of electronics, on the spot calibration of large gas meters, the use of an online chromatograph to determine the calorific value, the development of a calibration instrument, the so-called piston prover, to measure large quantities of natural gas, the recalibration of natural gas stations, the ultrasonic gas meter, and finally the quality of the natural gas supply. 1 fig., 11 ills

  3. Possibilities of gas-phase radio-chromatography application to permanent-gas analysis; Possibilites de la radiochromatographie en phase gazeuse applications a l'analyse des gaz permanents

    Energy Technology Data Exchange (ETDEWEB)

    Dupuis, M C; Charrier, G; Alba, C; Massimino, D [Commissariat a l' Energie Atomique, Bruyeres-le-Chatel (France). Centre d' Etudes

    1970-07-01

    The gas-phase radio-chromatography technique has been applied to the rapid analysis of permanent gases (H{sub 2}, O{sub 2}, N{sub 2}, A, Kr, Xe, CO, CH{sub 4}) labelled with radioactive indicators ({sup 3}H, {sup 37}A, {sup 85}Kr, {sup 133}Xe). After calibration, the components of such a mixture can be identified and their concentrations measured in less than two hours, using a sample volume of from 0.1 to 10 cm{sup 3}. The minimum detectable activity is of the order of 10{sup -4} {mu}C for each radioactive isotope. The measurements are reproducible to about 2 to 3 per cent. This work has been mainly concerned with the influence of parameters affecting the response of the radioactivity detector (ionization chamber or gas flow proportional counter). The method has very numerous applications both theoretically, for the study of chromatographic phenomena under ideal conditions (infinitesimal concentrations made possible by the use of radioactive tracers), and practically, for rapid and accurate radiochemical analysis of radioactive gas mixtures. (authors) [French] La technique de radiochromatographie en phase gazeuse est appliquee a l'analyse rapide de gaz permanents (H{sub 2}, O{sub 2}, N{sub 2}, A, Kr, Xe, CO, CH{sub 4}) marques par des indicateurs radioactifs ({sup 3}H, {sup 37}A, {sup 85}Kr, {sup 133}Xe). Apres etalonnage, l'identification et la mesure des concentrations des constituants d'un tel melange requierent moins de deux heures, sur un volume d'echantillon de 0.1 a 10 cm{sup 3}. L'activite minimum detectable est de l'ordre de 10{sup -4} {mu}C pour chaque isotope radioactif. La reproductibilite des mesures est de l'ordre de 2 a 3 pour cent. L'etude porte principalement sur l'influence des parametres affectant la reponse du detecteur de radioactivite (chambre d'ionisation, ou compteur proportionnel a circulation). La methode est extremement fertile en applications tant sur le plan theorique pour l'etude du phenomene chromatographique dans les conditions

  4. Supercooled liquid vapour pressures and related thermodynamic properties of polycyclic aromatic hydrocarbons determined by gas chromatography

    NARCIS (Netherlands)

    Haftka, J.J.H.; Parsons, J.R.; Govers, H.A.J.

    2006-01-01

    A gas chromatographic method using Kovats retention indices has been applied to determine the liquid vapour pressure (P-i), enthalpy of vaporization (Delta H-i) and difference in heat capacity between gas and liquid phase (Delta C-i) for a group of polycyclic aromatic hydrocarbons (PAHs). This group

  5. Enhanced Recovery in Tight Gas Reservoirs using Maxwell-Stefan Equations

    Science.gov (United States)

    Santiago, C. J. S.; Kantzas, A.

    2017-12-01

    Due to the steep production decline in unconventional gas reservoirs, enhanced recovery (ER) methods are receiving great attention from the industry. Wet gas or liquid rich reservoirs are the preferred ER candidates due to higher added value from natural gas liquids (NGL) production. ER in these reservoirs has the potential to add reserves by improving desorption and displacement of hydrocarbons through the medium. Nevertheless, analysis of gas transport at length scales of tight reservoirs is complicated because concomitant mechanisms are in place as pressure declines. In addition to viscous and Knudsen diffusion, multicomponent gas modeling includes competitive adsorption and molecular diffusion effects. Most models developed to address these mechanisms involve single component or binary mixtures. In this study, ER by gas injection is investigated in multicomponent (C1, C2, C3 and C4+, CO2 and N2) wet gas reservoirs. The competing effects of Knudsen and molecular diffusion are incorporated by using Maxwell-Stefan equations and the Dusty-Gas approach. This model was selected due to its superior properties on representing the physics of multicomponent gas flow, as demonstrated during the presented model validation. Sensitivity studies to evaluate adsorption, reservoir permeability and gas type effects are performed. The importance of competitive adsorption on production and displacement times is demonstrated. In the absence of adsorption, chromatographic separation is negligible. Production is merely dictated by competing effects between molecular and Knudsen diffusion. Displacement fronts travel rapidly across the medium. When adsorption effects are included, molecules with lower affinity to the adsorption sites will be produced faster. If the injected gas is inert (N2), an increase in heavier fraction composition occurs in the medium. During injection of adsorbing gases (CH4 and CO2), competitive adsorption effects will contribute to improved recovery of heavier

  6. Liquid chromatographic analysis of phenobarbitone, ethosuximide ...

    African Journals Online (AJOL)

    A liquid chromatographic method for the simultaneous assay of four anticonvulsant drugs, phenobarbitone, ethosuximide, phenytoin and carbamazepine on a polystyrene-divinyl benzene column is described. The method was developed by the systematic study of different types of co-polymer materials, type and ...

  7. Gas chromatography of β-diketonates

    International Nuclear Information System (INIS)

    Burgett, C.A.

    1976-01-01

    The history of separation of metal complexes by gas chromatography is reviewed. The greatest success has been achieved with metal halides or metal β-diketonates, particularly with chelates of the small elements, Be and Al, and the extremely inert chromium diketonates. Many problems still remain concerning the development of suitable chromatographic techniques for many chelates; however, the technique of synergic solvent extraction, mixed-ligand complex chromatography, the synthesis of new heteroatomic ligands, and the advent of new liquid phases are discussed as means to increase the number of unique techniques for separation and analysis of metals. Methods are suggested and references are cited for chromatographic analysis of elements in the following groups: alkali metals, alkaline earths, Group IIIA, IVB, VB, VIB, VIIB, VIII, IB, and IIB. Special attention is given to separation of the volatile complexes of Sc, Y, the lanthanides, the actinides, and Pb. 156 references

  8. Possibilities of gas-phase radio-chromatography application to permanent-gas analysis; Possibilites de la radiochromatographie en phase gazeuse applications a l'analyse des gaz permanents

    Energy Technology Data Exchange (ETDEWEB)

    Dupuis, M.C.; Charrier, G.; Alba, C.; Massimino, D. [Commissariat a l' Energie Atomique, Bruyeres-le-Chatel (France). Centre d' Etudes

    1970-07-01

    The gas-phase radio-chromatography technique has been applied to the rapid analysis of permanent gases (H{sub 2}, O{sub 2}, N{sub 2}, A, Kr, Xe, CO, CH{sub 4}) labelled with radioactive indicators ({sup 3}H, {sup 37}A, {sup 85}Kr, {sup 133}Xe). After calibration, the components of such a mixture can be identified and their concentrations measured in less than two hours, using a sample volume of from 0.1 to 10 cm{sup 3}. The minimum detectable activity is of the order of 10{sup -4} {mu}C for each radioactive isotope. The measurements are reproducible to about 2 to 3 per cent. This work has been mainly concerned with the influence of parameters affecting the response of the radioactivity detector (ionization chamber or gas flow proportional counter). The method has very numerous applications both theoretically, for the study of chromatographic phenomena under ideal conditions (infinitesimal concentrations made possible by the use of radioactive tracers), and practically, for rapid and accurate radiochemical analysis of radioactive gas mixtures. (authors) [French] La technique de radiochromatographie en phase gazeuse est appliquee a l'analyse rapide de gaz permanents (H{sub 2}, O{sub 2}, N{sub 2}, A, Kr, Xe, CO, CH{sub 4}) marques par des indicateurs radioactifs ({sup 3}H, {sup 37}A, {sup 85}Kr, {sup 133}Xe). Apres etalonnage, l'identification et la mesure des concentrations des constituants d'un tel melange requierent moins de deux heures, sur un volume d'echantillon de 0.1 a 10 cm{sup 3}. L'activite minimum detectable est de l'ordre de 10{sup -4} {mu}C pour chaque isotope radioactif. La reproductibilite des mesures est de l'ordre de 2 a 3 pour cent. L'etude porte principalement sur l'influence des parametres affectant la reponse du detecteur de radioactivite (chambre d'ionisation, ou compteur proportionnel a circulation). La methode est extremement fertile en applications tant sur le plan theorique pour l

  9. Artificial neural network model for photosynthetic pigments identification using multi wavelength chromatographic data

    Science.gov (United States)

    Prilianti, K. R.; Hariyanto, S.; Natali, F. D. D.; Indriatmoko, Adhiwibawa, M. A. S.; Limantara, L.; Brotosudarmo, T. H. P.

    2016-04-01

    The development of rapid and automatic pigment characterization method become an important issue due to the fact that there are only less than 1% of plant pigments in the earth have been explored. In this research, a mathematical model based on artificial intelligence approach was developed to simplify and accelerate pigment characterization process from HPLC (high-performance liquid chromatography) procedure. HPLC is a widely used technique to separate and identify pigments in a mixture. Input of the model is chromatographic data from HPLC device and output of the model is a list of pigments which is the spectrum pattern is discovered in it. This model provides two dimensional (retention time and wavelength) fingerprints for pigment characterization which is proven to be more accurate than one dimensional fingerprint (fixed wavelength). Moreover, by mimicking interconnection of the neuron in the nervous systems of the human brain, the model have learning ability that could be replacing expert judgement on evaluating spectrum pattern. In the preprocessing step, principal component analysis (PCA) was used to reduce the huge dimension of the chromatographic data. The aim of this step is to simplify the model and accelerate the identification process. Six photosynthetic pigments i.e. zeaxantin, pheophytin a, α-carotene, β-carotene, lycopene and lutein could be well identified by the model with accuracy up to 85.33% and processing time less than 1 second.

  10. Surface water and atmospheric carbon dioxide and nitrous oxide observations by shipboard automated gas chromatography: Results from expeditions between 1977 and 1990

    International Nuclear Information System (INIS)

    Weiss, R.F.; Van Woy, F.A.; Salameh, P.K.; Sepanski, R.J.

    1992-12-01

    This document presents the results of surface water and atmospheric carbon dioxide (CO 2 ) and nitrous oxide (N 2 O) measurements carried out by shipboard gas chromatography over the period 1977--1990. These data include results from 11 different oceanic surveys for a total of 41 expedition legs. Collectively, they represent a globally distributed sampling that includes locations in the Atlantic, Pacific, Indian, and Southern Oceans, as well as the Mediterranean and Red Seas. The measurements were made by an automated high-precision shipboard gas chromatographic system developed during the late 1970s and used extensively over the intervening years. This instrument measures CO 2 by flame ionization after quantitative reaction to methane in a stream of hydrogen. Nitrous oxide is measured by a separate electron capture detector. The chromatographic system measures 196 dry-gas samples a day, divided equally among the atmosphere, gas equilibrated with surface water, a low-range gas standard, and a high-range gas standard

  11. Chromatographic determination of the relative retention of isotopic species of oxygen in methanol and methan-d3-ol

    International Nuclear Information System (INIS)

    Pauls, R.E.; Mahle, N.H.; Shepard, A.T.; Gaw, J.C.; Rogers, L.B.

    1976-08-01

    A high-precision gas chromatograph was used in conjunction with a quadrupole mass filter and an on-line computer to study the fractionation of oxygen isotopes by Porapak T and glycerol in CH 3 OH and CD 3 OH as a function of temperature. Values of relative retention on the order of 1.002 compared favorably with results for the vapor pressure ratio obtained by classical means. Differences from unity were much smaller for the activity-coefficient ratio than for the vapor-pressure ratio. Differential thermodynamic data were also reported

  12. Appearance of rapid carbon on hydrogasification of coal; Suiten gas ka ni okeru kokassei tanso no hatsugen

    Energy Technology Data Exchange (ETDEWEB)

    Soneda, Y.; Makino, M. [National Institute for Resources and Environment, Tsukuba (Japan)9] Xu, W. [New Energy and Industrial Technology Development Organization, Tokyo, (Japan)

    1998-09-20

    The technology of hydrogasification of coal now under development under a State project aims to produce light oil as well as methane-rich high calorie gas through the direct reaction between coal and hydrogen, and is expected to deal with the difficult natural gas demand/supply relationship anticipated for the future. Although it is mandatory to fully understand the reaction between coal and hydrogen for the completion of this technology, yet there are many tasks to be fulfilled. One of the tasks is the elucidation of the behavior of what is named rapid carbon that appears upon the rapid heating of coal in a high-pressure hydrogen environment. In this paper, some interesting findings about the appearance of rapid carbon are reported. When coal is placed in such an environment, volatile components are lost first of all and then the active carbon reaction occurs. When the behavior of active carbon in the reaction is observed, it is found that active carbon is not so small in quantity, and the result of observation of its appearance and deactivation during the reaction justifies an inference that the reaction is regarded as one of the primary reactions in the process of hydrogasification. Accordingly, systematic studies of its physical and chemical features from various viewpoints are necessary. 5 refs., 3 figs., 1 tab.

  13. Conceptual design of hydrogen isotopes chromatographic separation system with super large capacity

    International Nuclear Information System (INIS)

    Xie Bo; Weng Kuiping; Liu Yunnu; Hou Jianping

    2012-01-01

    A super large capacity hydrogen isotopes separation system, including total plan, unit (including making and purification of gas, three-grade chromatographic columns, gas loop and auto-control, and carrier recovery) and experimental scheme, had been designed on the basis of a series of hydrogen-deuterium experiments by temperature programmed de- sorption. The characteristic of the system was that desorption kinetic parameters could be directly calculated from the hydrogen isotope separation desorption spectra information. In other words, the complicated dynamic process of separation could be described by the desorption rate equation, shape parameter and desorption activation energy calculation on the condition of the experimental data and appropriate assumptions (equilibrium and adsorption, uniform surface). In previous work, an experimental series of operation to verify the successive enrichment of D 2 from a H 2 -D 2 mixture, the production of the deuterium from natural hydrogen and the recovery of tritium such as from the nuclear heavy-water were carried out using MS5A at 77 K. This work was only conceptual design, so it was necessary to identify the availability of super large capacity system by experiment. (authors)

  14. Microfabricated gas chromatograph for on-site determinations of TCE in indoor air arising from vapor intrusion. 2. Spatial/temporal monitoring.

    Science.gov (United States)

    Kim, Sun Kyu; Burris, David R; Bryant-Genevier, Jonathan; Gorder, Kyle A; Dettenmaier, Erik M; Zellers, Edward T

    2012-06-05

    We demonstrate the use of two prototype Si-microfabricated gas chromatographs (μGC) for continuous, short-term measurements of indoor trichloroethylene (TCE) vapor concentrations related to the investigation of TCE vapor intrusion (VI) in two houses. In the first house, with documented TCE VI, temporal variations in TCE air concentrations were monitored continuously for up to 48 h near the primary VI entry location under different levels of induced differential pressure (relative to the subslab). Concentrations ranged from 0.23 to 27 ppb by volume (1.2-150 μg/m(3)), and concentration trends agreed closely with those determined from concurrent reference samples. The sensitivity and temporal resolution of the measurements were sufficiently high to detect transient fluctuations in concentration resulting from short-term changes in variables affecting the extent of VI. Spatial monitoring showed a decreasing TCE concentration gradient with increasing distance from the primary VI entry location. In the second house, with no TCE VI, spatial profiles derived from the μGC prototype data revealed an intentionally hidden source of TCE within a closet, demonstrating the capability for locating non-VI sources. Concentrations measured in this house ranged from 0.51 to 56 ppb (2.7-300 μg/m(3)), in good agreement with reference method values. This first field demonstration of μGC technology for automated, near-real-time, selective VOC monitoring at low- or subppb levels augurs well for its use in short- and long-term on-site analysis of indoor air in support of VI assessments.

  15. Liquid chromatographic-mass spectrometric method for ...

    African Journals Online (AJOL)

    Tropical Journal of Pharmaceutical Research ... Purpose: To develop and validate a simple, efficient and reliable Liquid chromatographic-mass spectrometric (LC-MS/MS) method for the quantitative determination of two dermatological drugs, ... By Country · List All Titles · Free To Read Titles This Journal is Open Access.

  16. A hybrid thermal video and FTIR spectrometer system for rapidly locating and characterizing gas leaks

    Science.gov (United States)

    Williams, David J.; Wadsworth, Winthrop; Salvaggio, Carl; Messinger, David W.

    2006-08-01

    Undiscovered gas leaks, known as fugitive emissions, in chemical plants and refinery operations can impact regional air quality and present a loss of product for industry. Surveying a facility for potential gas leaks can be a daunting task. Industrial leak detection and repair programs can be expensive to administer. An efficient, accurate and cost effective method for detecting and quantifying gas leaks would both save industries money by identifying production losses and improve regional air quality. Specialized thermal video systems have proven effective in rapidly locating gas leaks. These systems, however, do not have the spectral resolution for compound identification. Passive FTIR spectrometers can be used for gas compound identification, but using these systems for facility surveys is problematic due to their small field of view. A hybrid approach has been developed that utilizes the thermal video system to locate gas plumes using real time visualization of the leaks, coupled with the high spectral resolution FTIR spectrometer for compound identification and quantification. The prototype hybrid video/spectrometer system uses a sterling cooled thermal camera, operating in the MWIR (3-5 μm) with an additional notch filter set at around 3.4 μm, which allows for the visualization of gas compounds that absorb in this narrow spectral range, such as alkane hydrocarbons. This camera is positioned alongside of a portable, high speed passive FTIR spectrometer, which has a spectral range of 2 - 25 μm and operates at 4 cm -1 resolution. This system uses a 10 cm telescope foreoptic with an onboard blackbody for calibration. The two units are optically aligned using a turning mirror on the spectrometer's telescope with the video camera's output.

  17. Efficient quantification of water content in edible oils by headspace gas chromatography with vapour phase calibration.

    Science.gov (United States)

    Xie, Wei-Qi; Gong, Yi-Xian; Yu, Kong-Xian

    2018-06-01

    An automated and accurate headspace gas chromatographic (HS-GC) technique was investigated for rapidly quantifying water content in edible oils. In this method, multiple headspace extraction (MHE) procedures were used to analyse the integrated water content from the edible oil sample. A simple vapour phase calibration technique with an external vapour standard was used to calibrate both the water content in the gas phase and the total weight of water in edible oil sample. After that the water in edible oils can be quantified. The data showed that the relative standard deviation of the present HS-GC method in the precision test was less than 1.13%, the relative differences between the new method and a reference method (i.e. the oven-drying method) were no more than 1.62%. The present HS-GC method is automated, accurate, efficient, and can be a reliable tool for quantifying water content in edible oil related products and research. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  18. Gas chromatographic analysis of extractive solvent in reprocessing plants

    International Nuclear Information System (INIS)

    Marlet, B.

    1984-01-01

    Operation of a reprocessing plant using the Purex process is recalled and analytical controls for optimum performance are specified. The aim of this thesis is the development of analytical methods using gas chromatography required to follow the evolution of the extraction solvent during spent fuel reprocessing. The solvent at different concentrations, is analysed along the reprocessing lines in organic or aqueous phases. Solvent degradation interferes with extraction and decomposition products are analysed. The solvent becomes less and less efficient, also it is distilled and quality is checked. Traces of solvent should also be checked in waste water. Analysis are made as simple as possible to facilitate handling of radioactive samples [fr

  19. Carbon-Nanotube-Based Chemical Gas Sensor

    Science.gov (United States)

    Kaul, Arunpama B.

    2010-01-01

    Conventional thermal conductivity gauges (e.g. Pirani gauges) lend themselves to applications such as leak detectors, or in gas chromatographs for identifying various gas species. However, these conventional gauges are physically large, operate at high power, and have a slow response time. A single-walled carbon-nanotube (SWNT)-based chemical sensing gauge relies on differences in thermal conductance of the respective gases surrounding the CNT as it is voltage-biased, as a means for chemical identification. Such a sensor provides benefits of significantly reduced size and compactness, fast response time, low-power operation, and inexpensive manufacturing since it can be batch-fabricated using Si integrated-circuit (IC) process technology.

  20. Use of coextraction and suppression of extraction in extraction-chromatographic separation of elements

    International Nuclear Information System (INIS)

    Karandashev, V.K.; Kuznetsov, R.A.; Grazhulene, S.S.; Usmanova, M.M.

    1988-01-01

    TBP, solutions of hydrobromic acid, indium and polytetrafluoroethylene powder, carrier for TBP, were used to study the effects of coextraction and extraction suppression on extraction-chromatographic behaviour of microamounts of elements in the presence of macroamounts of other elements. Possibility of using these effects under extraction-chromatographic element separation were considered. A new method for extraction-chromatographic separation of scandium microamounts from the mixture of large amount of elements (Y, Cd, Ce, Eu, Lu, Hf, Ta, W, Np and other) was suggested. 15 refs.; 3 figs

  1. Rio Vista gas leak study: Belleaire Gas Field, California

    International Nuclear Information System (INIS)

    Wilkey, P.L.

    1992-08-01

    The Rio Vista gas leak study evaluated methods for remotely sensing gas leaks from buried pipelines and developed methods to elucidate methane transport and microbial oxidation in soils. Remote-sensing methods were evaluated by singing gas leaks along an abandoned Pacific Gas and Electric (PG ampersand E) gas field collection line in northern California and applying surface-based and airborne remote-sensing techniques in the field, including thermal imaging, laser imaging, and multispectral imagery. The remote-sensing techniques exhibited limitations in range and in their ability to correlate with ground truth data. To elucidate methane transport and microbial oxidation in soils, a study of a controlled leak permitted field testing of methods so that such processes could be monitored and evaluated. Monitoring and evaluation techniques included (1) field measurement of soil-gas concentrations, temperatures, and pressures; (2) laboratory measurement of soil physical/chemical properties and activity of methane-oxidizing microorganisms by means of field samples; and (3) development of a preliminary numerical analysis technique for combined soil-gas transport/methane oxidation. Soil-gas concentrations at various depths responded rapidly to the high rate of gas leakage. The number of methane-oxidizing microorganisms in site soils rapidly increased when the gas leak was initiated and decreased after the leak was terminated. The preliminary field, laboratory, and numerical analysis techniques tested for this study of a controlled gas leak could be successfully applied to future studies of gas leaks. Because soil-gas movement is rapid and temporally variable, the use of several complementary techniques that permit generalization of site-specific results is favored

  2. Ion Chromatographic Analyses of Sea Waters, Brines and Related Samples

    OpenAIRE

    Nataša Gros

    2013-01-01

    This review focuses on the ion chromatographic methods for the analyses of natural waters with high ionic strength. At the beginning a natural diversity in ionic composition of waters is highlighted and terminology clarified. In continuation a brief overview of other review articles of potential interest is given. A review of ion chromatographic methods is organized in four sections. The first section comprises articles focused on the determination of ionic composition of water samples as com...

  3. Simultaneous determination of carbohydrates and simmondsins in jojoba seed meal (Simmondsia chinensis) by gas chromatography.

    Science.gov (United States)

    Lein, Sabine; Van Boven, Maurits; Holser, Ron; Decuypere, Eddy; Flo, Gerda; Lievens, Sylvia; Cokelaere, Marnix

    2002-11-22

    Separate methods for the analyses of soluble carbohydrates in different plants and simmondsins in jojoba seed meal are described. A reliable gas chromatographic procedure for the simultaneous quantification of D-pinitol, myo-inositoL sucrose, 5-alpha-D-galactopyranosyl-D-pinitol. 2-alpha-D-galactopyranosyl-D-pinitol, simmondsin, 4-demethylsimmondsin, 5-demethylsimmondsin and 4,5-didemethylsimmondsin as trimethylsilyl derivatives in jojoba seed meal has been developed. The study of different extraction mixtures allowed for the quantitative recovery of the 9 analytes by a mixture of methanol-water (80:20, v/v) in the concentration range between 0.1 and 4%. Comparison of the separation parameters on three different capillary stationary phases with MS detection allowed for the choice of the optimal gas chromatographic conditions for baseline separation of the analytes.

  4. Identification and measurement of chlorinated organic pesticides in water by electron-capture gas chromatography

    Science.gov (United States)

    Lamar, William L.; Goerlitz, Donald F.; Law, LeRoy M.

    1965-01-01

    Pesticides, in minute quantities, may affect the regimen of streams, and because they may concentrate in sediments, aquatic organisms, and edible aquatic foods, their detection and their measurement in the parts-per-trillion range are considered essential. In 1964 the U.S. Geological Survey at Menlo Park, Calif., began research on methods for monitoring pesticides in water. Two systems were selected--electron-capture gas chromatography and microcoulometric-titration gas chromatography. Studies on these systems are now in progress. This report provides current information on the development and application of an electron-capture gas chromatographic procedure. This method is a convenient and extremely sensitive procedure for the detection and measurement of organic pesticides having high electron affinities, notably the chlorinated organic pesticides. The electron-affinity detector is extremely sensitive to these substances but it is not as sensitive to many other compounds. By this method, the chlorinated organic pesticide may be determined on a sample of convenient size in concentrations as low as the parts-per-trillion range. To insure greater accuracy in the identifications, the pesticides reported were separated and identified by their retention times on two different types of gas chromatographic columns.

  5. Asia Gas Study

    International Nuclear Information System (INIS)

    1996-01-01

    The Asia region has experienced a period of dynamic growth, both of economies and energy demand. The next fifteen years are likely to see further rapid economic growth in Asia. To fuel this growth energy consumption will also increase rapidly. Of all forms of energy, natural gas demand is likely to grow the fastest. The gas sector will face rapid and dramatic change, creating challenges for the governments of the region. Infrastructure, both for export and domestic consumption of gas, will need to expand significantly. Regional trade in natural gas could triple by 2010. Trade will continue to be dominated by liquefied natural gas (LNG) but pipeline exports will also grow rapidly. Investment needs will be large, putting pressure on governments to look for alternative funding mechanisms. As Asian gas transmission and distribution networks expand and become more interconnected, consumer choice becomes possible. How to encourage and regulate competition will become a vital policy question. As gas consumption increases both in absolute terms, and in terms of its share of energy consumption within particular sectors of the economy (for example, as a fuel for power generation), governments will need to give higher priority to policies dealing with gas security. This study examines the current and possible future role of natural gas in Asia. In particular, it examines in detail the relevant energy policies of six of the key gas producing and consuming economies in the region: Brunei-Darussalam, Chinese Taipei, Indonesia, the Republic of Korea, Malaysia and Thailand. (author). 17 figs., 14 tabs., 7 appends

  6. Rapid method to determine actinides and 89/90Sr in limestone and marble samples

    International Nuclear Information System (INIS)

    Maxwell, S.L.; Culligan, Brian; Hutchison, J.B.; Utsey, R.C.; Sudowe, Ralf; McAlister, D.R.

    2016-01-01

    A new method for the determination of actinides and radiostrontium in limestone and marble samples has been developed that utilizes a rapid sodium hydroxide fusion to digest the sample. Following rapid pre-concentration steps to remove sample matrix interferences, the actinides and 89 / 90 Sr are separated using extraction chromatographic resins and measured radiometrically. The advantages of sodium hydroxide fusion versus other fusion techniques will be discussed. This approach has a sample preparation time for limestone and marble samples of <4 h. (author)

  7. Characterizing the selectivity of stationary phases and organic modifiers in reversed-phase high-performance liquid chromatographic systems by a general solvation equation using gradient elution.

    Science.gov (United States)

    Du, C M; Valko, K; Bevan, C; Reynolds, D; Abraham, M H

    2000-11-01

    Retention data for a set of 69 compounds using rapid gradient elution are obtained on a wide range of reversed-phase stationary phases and organic modifiers. The chromatographic stationary phases studied are Inertsil (IN)-ODS, pentafluorophenyl, fluoro-octyl, n-propylcyano, Polymer (PLRP-S 100), and hexylphenyl. The organic solvent modifiers are 2,2,2-trifluoroethanol (TFE); 1,1,1,3,3,3-hexafluoropropan-2-ol (HFIP); isopropanol; methanol (MeOH); acetonitrile (AcN); tetrahydrofuran; 1,4-dioxane; N,N-dimethylformamide; and mixed solvents of dimethylsulfoxide (DMSO) with AcN and DMSO with MeOH (1:1). A total of 25 chromatographic systems are analyzed using a solvation equation. In general, most of the systems give reasonable statistics. The selectivity of the reversed phase-high-performance liquid chromatographic (HPLC) systems with respect to the solute's dipolarity-polarity, hydrogen-bond acidity, and basicity are reflected in correspondingly large coefficients in the solvation equation. We wanted to find the most orthogonal HPLC systems, showing the highest possible selectivity difference in order to derive molecular descriptors using the gradient retention times of a compound. We selected eight chromatographic systems that have a large range of coefficients of interest (s, a, and b) similar to those found in water-solvent partitions used previously to derive molecular descriptors. The systems selected are IN-ODS phases with AcN, MeOH, TFE, and HFIP as mobile phase, PLRP-S 100 phase with AcN, propylcyano phase with AcN and MeOH, and fluorooctyl phase with TFE. Using the retention data obtained for a compound in the selected chromatographic systems, we can estimate the molecular descriptors with the faster and simpler gradient elution method.

  8. High-performance liquid-chromatographic separation of subcomponents of antimycin-A

    Science.gov (United States)

    Abidi, S.L.

    1988-01-01

    Using a reversed-phase high-performance liquid chromatographic (HPLC) technique, a mixture of antimycins A was separated into eight hitherto unreported subcomponents, Ala, Alb, A2a, A2b, A3a, A3b, A4a, and A4b. Although a base-line resolution of the known four major antimycins Al, A2, A3, and A4 was readily achieved with mobile phases containing acetate buffers, the separation of the new antibiotic subcomponents was highly sensitive to variation in mobile phase conditions. The type and composition of organic modifiers, the nature of buffer salts, and the concentration of added electrolytes had profound effects on capacity factors, separation factors, and peak resolution values. Of the numerous chromatographic systems examined, a mobile phase consisting of methanol-water (70:30) and 0.005 M tetrabutylammonium phosphate at pH 3.0 yielded the most satisfactory results for the separation of the subcomponents. Reversed-phase gradient HPLC separation of the dansylated or methylated antibiotic compounds produced superior chromatographic characteristics and the presence of added electrolytes was not a critical factor for achieving separation. Differences in the chromatographic outcome between homologous and structural isomers were interpretated based on a differential solvophobic interaction rationale. Preparative reversed-phase HPLC under optimal conditions enabled isolation of pure samples of the methylated antimycin subcomponents for use in structural studies.

  9. Chromatographic decontamination of medium-activity waste concentrates

    International Nuclear Information System (INIS)

    Faubel, W.; Menzler, P.M.; Sameh, A.A.

    1988-01-01

    The chromatographic decontamination of a MAW concentrate was carried out in a laboratory plant in 1-l-batches in the following way: In order to purify the nitric MAW concentrate from its solid and organic contamination products, it is passed through a filter and an absorber (SM7) for organic species. Subsequently the purified solution runs on-line through all following columns. First the main activity carrier cesium ( 137 Cs, 134 Cs) is transferred to ammonium molybdate phosphate (AMP-1) by means of a newly developed fluidized bed process. In the further course, 125 Sb is separated on metal oxides (Sb 2 O 5 , MnO 2 ) and the three-valued actinides/lanthanides on an extraction-chromatographic CMPO column. Finally the remaining 106 Ru and 60 Co activities are separated on dimethylglyoximes (DMG) coated on active carbon. (orig./RB) [de

  10. A solid-phase microextraction-gas chromatographic approach combined with triple quadrupole mass spectrometry for the assay of carbamate pesticides in water samples.

    Science.gov (United States)

    Cavaliere, Brunella; Monteleone, Marcello; Naccarato, Attilio; Sindona, Giovanni; Tagarelli, Antonio

    2012-09-28

    A simple and sensitive method was developed for the quantification of five carbamate pesticides in water samples using solid phase microextraction (SPME) combined with gas chromatography-triple quadrupole mass spectrometry (GC-QqQ-MS). The performance of five SPME fibers was tested in univariate mode whereas the other variables affecting the efficiency of SPME analysis were optimized by the multivariate approach of design of experiment (DoE) and, in particular, a central composite design (CCD) was applied. The optimum working conditions in terms of response values were achieved by performing analysis with polydimethylsiloxane/divinylbenzene (PDMS/DVB) fiber in immersion mode for 45min at room temperature with addition of NaCl (10%). The multivariate chemometric approach was also used to explore the chromatographic behavior of the carbamates and to evaluate the importance of each variable investigated. An overall appraisement of results shows that the factor which gave a statistically significant effect on the response was only the injection temperature. Identification and quantification of carbamates was performed by using a gas chromatography-triple quadrupole mass spectrometry (GC-QqQ-MS) system in multiple reaction monitoring (MRM) acquisition. Since the choice of internal standard represented a crucial step in the development of method to achieve good reproducibility and robustness for the entire analytical protocol, three compounds (2,3,5-trimethacarb, 4-bromo-3,5-dimethylphenyl-n-methylcarbamate (BDMC) and carbaryl-d7) were evaluated as internal standards. Both precision and accuracy of the proposed protocol tested at concentration of 0.08, 5 and 3 μg l⁻¹ offered values ranging from 70.8% and 115.7% (except for carbaryl at 3 μg l⁻¹) and from 1.0% and 9.0% for accuracy and precision, respectively. Moreover, LOD and LOQ values ranging from 0.04 to 1.7 ng l⁻¹ and from 0.64 to 2.9 ng l⁻¹, respectively, can be considered very satisfactory. Copyright

  11. Versatile, ultra-low sample volume gas analyzer using a rapid, broad-tuning ECQCL and a hollow fiber gas cell

    Science.gov (United States)

    Kriesel, Jason M.; Makarem, Camille N.; Phillips, Mark C.; Moran, James J.; Coleman, Max L.; Christensen, Lance E.; Kelly, James F.

    2017-05-01

    We describe a versatile mid-infrared (Mid-IR) spectroscopy system developed to measure the concentration of a wide range of gases with an ultra-low sample size. The system combines a rapidly-swept external cavity quantum cascade laser (ECQCL) with a hollow fiber gas cell. The ECQCL has sufficient spectral resolution and reproducibility to measure gases with narrow features (e.g., water, methane, ammonia, etc.), and also the spectral tuning range needed to measure volatile organic compounds (VOCs), (e.g., aldehydes, ketones, hydrocarbons), sulfur compounds, chlorine compounds, etc. The hollow fiber is a capillary tube having an internal reflective coating optimized for transmitting the Mid-IR laser beam to a detector. Sample gas introduced into the fiber (e.g., internal volume = 0.6 ml) interacts strongly with the laser beam, and despite relatively modest path lengths (e.g., L 3 m), the requisite quantity of sample needed for sensitive measurements can be significantly less than what is required using conventional IR laser spectroscopy systems. Example measurements are presented including quantification of VOCs relevant for human breath analysis with a sensitivity of 2 picomoles at a 1 Hz data rate.

  12. Versatile, ultra-low sample volume gas analyzer using a rapid, broad-tuning ECQCL and a hollow fiber gas cell

    Energy Technology Data Exchange (ETDEWEB)

    Kriesel, Jason M.; Makarem, Camille N.; Phillips, Mark C.; Moran, James J.; Coleman, Max; Christensen, Lance; Kelly, James F.

    2017-05-05

    We describe a versatile mid-infrared (Mid-IR) spectroscopy system developed to measure the concentration of a wide range of gases with an ultra-low sample size. The system combines a rapidly-swept external cavity quantum cascade laser (ECQCL) with a hollow fiber gas cell. The ECQCL has sufficient spectral resolution and reproducibility to measure gases with narrow features (e.g., water, methane, ammonia, etc.), and also the spectral tuning range needed to measure volatile organic compounds (VOCs), (e.g., aldehydes, ketones, hydrocarbons), sulfur compounds, chlorine compounds, etc. The hollow fiber is a capillary tube having an internal reflective coating optimized for transmitting the Mid-IR laser beam to a detector. Sample gas introduced into the fiber (e.g., internal volume = 0.6 ml) interacts strongly with the laser beam, and despite relatively modest path lengths (e.g., L ~ 3 m), the requisite quantity of sample needed for sensitive measurements can be significantly less than what is required using conventional IR laser spectroscopy systems. Example measurements are presented including quantification of VOCs relevant for human breath analysis with a sensitivity of ~2 picomoles at a 1 Hz data rate.

  13. An investigation of the matrix sensitivity of refinery gas analysis using gas chromatography with flame ionisation detection.

    Science.gov (United States)

    Ferracci, Valerio; Brown, Andrew S; Harris, Peter M; Brown, Richard J C

    2015-02-27

    The response of a flame ionisation detector (FID) on a gas chromatograph to methane, ethane, propane, i-butane and n-butane in a series of multi-component refinery gas standards was investigated to assess the matrix sensitivity of the instrument. High-accuracy synthetic gas standards, traceable to the International System of Units, were used to minimise uncertainties. The instrument response exhibited a small dependence on the component amount fraction: this behaviour, consistent with that of another FID, was thoroughly characterised over a wide range of component amount fractions and was shown to introduce a negligible bias in the analysis of refinery gas samples, provided a suitable reference standard is employed. No significant effects of the molar volume, density and viscosity of the gas mixtures on the instrument response were observed, indicating that the FID is suitable for the analysis of refinery gas mixtures over a wide range of component amount fractions provided that appropriate drift-correction procedures are employed. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Analytical Method Development and Validation for the Quantification of Acetone and Isopropyl Alcohol in the Tartaric Acid Base Pellets of Dipyridamole Modified Release Capsules by Using Headspace Gas Chromatographic Technique

    Directory of Open Access Journals (Sweden)

    Sriram Valavala

    2018-01-01

    Full Text Available A simple, sensitive, accurate, robust headspace gas chromatographic method was developed for the quantitative determination of acetone and isopropyl alcohol in tartaric acid-based pellets of dipyridamole modified release capsules. The residual solvents acetone and isopropyl alcohol were used in the manufacturing process of the tartaric acid-based pellets of dipyridamole modified release capsules by considering the solubility of the dipyridamole and excipients in the different manufacturing stages. The method was developed and optimized by using fused silica DB-624 (30 m × 0.32 mm × 1.8 µm column with the flame ionization detector. The method validation was carried out with regard to the guidelines for validation of analytical procedures Q2 demanded by the International Council for Harmonisation of Technical Requirements for Pharmaceuticals for Human Use (ICH. All the validation characteristics were meeting the acceptance criteria. Hence, the developed and validated method can be applied for the intended routine analysis.

  15. Radio Column Chromatographic Assay of H3-Labelled Substances

    International Nuclear Information System (INIS)

    Scharpenseel, H.W.; Menke, K.H.

    1962-01-01

    Combined radio-chromatographic investigations of H 3 -labelled substances are an integral part of the majority of biochemical experiments with H 3 -labelled compounds. H 3 -radio paper chromatography yields, in a scanner with a windowless flow counter, a counting efficiency of 0,5 -1,5%, depending largely on the thickness of the paper and the self-absorption of the labelled compound. The radio gas chromatography of tritiated compounds presents no major problem. Successful use is being made of a combination of a gas chromatograph with a flow ionization chamber and vibrating reed electrometer, a system originated by K. E. Wilzbach and P. Riessz, and improved by H. Dutton, L. Mason and L. Blair. Through the use of ''Teflon'' and silicone-rubber for the insulating parts of the flow ion chamber, it can be operated at close to 300 o C. Radio column chromatography with tritium holds little promise, when the column effluent is spread out as a shallow layer and slowly passes under a windowless flow counter or a scintillation counter, as was successfully tried with C 14 . Liquid scintillation spectrometry is likely to be the chosen method. Essentially, there are two different approaches feasible. These have been compared: 1. The column effluent is passed through a coil of plastic scintillator tubing, which is wound around a ''Plexiglas'' cylinder and placed in a bath of silicone oil in a light pipe with TiO 2 -reflector. Similarly, the HP-containing effluent can be directed through a test vial, filled - very much as in Steinberg's method - with plastic scintillator beads. These two approaches, that operate highly satisfactorily in the case of C 14 , offer low counting efficiencies of less than 1% for H 3 due to the unfavourable surface to volume ratio. 2. The column effluent is combined 1:30 with a mixture of 3:2 toluene/ethanol by the action of a magnet-vibrator before being assayed while passing through a K 40 -free glass - coiled between the analyser- and monitor

  16. Some aspects of the analysis of labelled organic compounds by gas radiochromatography

    International Nuclear Information System (INIS)

    Heise, K.H.; Gorner, Ch.; Bubner, M.

    1977-01-01

    The first experience with the analysis of tritium-and 14 C-labelled compounds by gas radiochromatography are reported. The instrumental arrangement is described where, on the chromatograph output, the radioactive compounds are burnt, and the radioactive gases are measured by scintillation detectors in a coincidence circuit

  17. Rapid and Automated Determination of Plutonium and Neptunium in Environmental Samples

    DEFF Research Database (Denmark)

    Qiao, Jixin

    This thesis presents improved analytical methods for rapid and automated determination of plutonium and neptunium in environmental samples using sequential injection (SI) based chromatography and inductively coupled plasma mass spectrometry (ICP-MS). The progress of methodology development...... and optimization for rapid determination of plutonium in environmental samples using SIextraction chromatography prior to inductively coupled plasma mass spectrometry (Paper III); (3) Development of an SI-chromatographic method for simultaneous determination of plutonium and neptunium in environmental samples...... for rapid and simultaneous determination of plutonium and neptunium within an SI system (Paper VI). The results demonstrate that the developed methods in this study are reliable and efficient for accurate assays of trace levels of plutonium and neptunium as demanded in different situations including...

  18. Research on waterhammer caused by a rapid gas production in the severe accident of a light water reactor

    International Nuclear Information System (INIS)

    Inasaka, Fujio; Adachi, Masaki; Shiozaki, Kohki; Aya, Izuo; Nariai, Hideki

    2004-01-01

    In the severe accident of an LWR (Light Water Reactor), it is supposed that a large quantity of gas is generated in a water pool of the containment vessel due to a water-metal reaction or a steam explosion. A rapid bubble growth, if the water mass is pushed up having a coherency in time and direction in its movement, would give a severe waterhammer to the structure. In this study, we conducted experiments using two cylindrical model containment vessels with 1.0 and 0.428 m diameters, and investigated the behavior of water mass pushed up by a growing bubble and the scale effect of this phenomenon. In addition, we also closely observed the heavier of a growing bubble. In these experiments, a rapid bubble growth was simulated by injecting high-pressure air into a water pool. It was observed that the water mass was pushed up without an air penetration until the water level reached a certain elevation. On the basis of all data, experimental correlations which gave a rise distance or velocity of the water mass with coherency were proposed and the waterhammer pressure which affected the structure was quantitatively evaluated. The applicability of the existing two-phase flow numerical analysis code, RELAP5-3D to the waterhammer phenomenon caused by a rapid gas production was also verified. (author)

  19. Studies on the separation of hydrogen isotopes and spin isomers by gas chromatography

    International Nuclear Information System (INIS)

    Pushpa, K.K.; Annaji Rao, K.

    2000-08-01

    Separation and analysis of mixture of hydrogen isotopes has gained considerable importance because of various applications needing different isotopes in lasers, nuclear reactions and tracer or labelled compounds. In the literature gas chromatographic methods are reported using columns packed with partly dehydrated or thoroughly dehydrated alumina/molecular sieve stationary phase at 77 deg K with helium, neon and even hydrogen or deuterium as carrier gas. In the present study an attempt is made to compare the chromatographic behaviour of these two stationary phases using virgin and Fe doped form in partly dehydrated and thoroughly dehydrated state, using helium, neon, hydrogen and deuterium as carrier gas. The results of this study show that helium or neon carrier gas behave similarly broad peaks with some tailing. Sharp symmetric peaks are obtained with hydrogen or deuterium carrier gas. This is attributed to large hold up capacity for H 2 or D 2 at 77 deg K in these materials as compared to helium or neon. Spin isomers of H 2 or D 2 are separated on Fe free stationary phases, though ortho H 2 and HD are not resolved. Using a combination of Fe doped short column and plain alumina column, both maintained in dehydrated form, the effect of Fe doping on thermal equilibrium of ortho/para forms at 77 deg K is clearly demonstrated. (author)

  20. Developing a Natural Gas-Powered Bus Rapid Transit Service: A Case Study

    Energy Technology Data Exchange (ETDEWEB)

    Mitchell, G.

    2015-11-03

    The Roaring Fork Transit Authority (RFTA) and its VelociRFTA Bus Rapid Transit (BRT) program are unique in many ways. For example, VelociRFTA was the first rural BRT system in the United States and the operational environment of the VelociRFTA BRT is one of the most severe in the country, with extreme winter temperatures and altitudes close to 8,000 feet. RFTA viewed high altitude operation as the most challenging characteristic when it began considering the use of natural gas. RFTA is the second-largest public transit system in Colorado behind Denver's Regional Transportation District (RTD), and it is one of the largest rural public transit systems in the country. In 2013, RFTA accepted delivery of 22 new compressed natural gas (CNG) buses that went into service after completion of maintenance and refueling facilities earlier that year. This paper examines the lessons learned from RFTA's experience of investigating--and ultimately choosing--CNG for their new BRT program and focuses on the unique environment of RFTA's BRT application; the decision process to include CNG fueling in the project; unforeseen difficulties encountered in the operation of CNG buses; public perception; cost comparison to competing fuels; and considerations for indoor fueling facilities and project funding.

  1. Developing a Natural Gas-Powered Bus Rapid Transit Service. A Case Study

    Energy Technology Data Exchange (ETDEWEB)

    Mitchell, George [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2015-11-01

    The Roaring Fork Transit Authority (RFTA) and its VelociRFTA Bus Rapid Transit (BRT) program are unique in many ways. For example, VelociRFTA was the first rural BRT system in the United States and the operational environment of the VelociRFTA BRT is one of the most severe in the country, with extreme winter temperatures and altitudes close to 8,000 feet. RFTA viewed high altitude operation as the most challenging characteristic when it began considering the use of natural gas. RFTA is the second-largest public transit system in Colorado behind Denver's Regional Transportation District (RTD), and it is one of the largest rural public transit systems in the country. In 2013, RFTA accepted delivery of 22 new compressed natural gas (CNG) buses that went into service after completion of maintenance and refueling facilities earlier that year. This paper examines the lessons learned from RFTA's experience of investigating--and ultimately choosing--CNG for their new BRT program and focuses on the unique environment of RFTA's BRT application; the decision process to include CNG fueling in the project; unforeseen difficulties encountered in the operation of CNG buses; public perception; cost comparison to competing fuels; and considerations for indoor fueling facilities and project funding.

  2. Finland: Scandinavia's top gas user sees demand rising rapidly

    International Nuclear Information System (INIS)

    Nielsen, H.H.

    1992-01-01

    The rising demand for natural gas in Finland which already uses more gas than any other Nordic country is noted. The natural gas market which is based on sales to large industries and for heating is compared to the market in Denmark which is geared to small private heating customers. Imports of Norwegian gas allowing increased sales for power generation in Finland, and the influence of the impending Finnish application for membership of the EC on the gas market are considered. (UK)

  3. Rapid injection of particles and gas into non-fluidized granular material, and some volcanological implications

    Science.gov (United States)

    Ross, Pierre-Simon; White, James D. L.; Zimanowski, Bernd; Büttner, Ralf

    2008-10-01

    In diatremes and other volcanic vents, steep bodies of volcaniclastic material having differing properties (particle size distribution, proportion of lithic fragments, etc.) from those of the surrounding vent-filling volcaniclastic material are often found. It has been proposed that cylindrical or cone-shaped bodies result from the passage of “debris jets” generated after phreatomagmatic explosions or other discrete subterranean bursts. To learn more about such phenomena, we model experimentally the injection of gas-particulate dispersions through other particles. Analogue materials (glass beads or sand) and a finite amount of compressed air are used in the laboratory. The gas is made available by rapidly opening a valve—therefore the injection of gas and coloured particles into a granular host is a brief (non-erupting injections produce cylindrical bodies of coloured beads whereas erupting runs produce flaring upward or conical deposits. Changing the particle size of the host glass beads does not have a large effect under the size range investigated (100 200 to 300 400 μm). Doubling the host thickness (injection depth) requires a doubling of the initial gas pressure to produce similar phenomena. Such injections—whether erupting or wholly subterranean—provide a compelling explanation for the origin and characteristics of multiple cross-cutting bodies that have been documented for diatreme and other vent deposits.

  4. Radiolytic gas formation in high-level liquid waste solutions

    International Nuclear Information System (INIS)

    Brodda, B.-G.; Dix, Siegfried; Merz, E.R.

    1989-01-01

    High-level fission product waste solutions originating from the first-cycle raffinate stream of spent fast breeder reactor fuel reprocessing have been investigated gas chromatographically for their radiolytic and chemical gas production. The solutions showed considerable formation of hydrogen, carbon dioxide and dinitrogen oxide, whereas atmospheric oxygen was consumed completely within a short time. In particular, carbon dioxide resulted from the radiolytic degradation of entrained organic solvent. After nearly complete degradation of the organic solvent, the influence of hydrazine and nitrogen dioxide on hydrogen formation was investigated. Hydrazinium hydroxide led to the formation of dinitrogen oxide and nitrogen. After 60 d, the concentration of dinitrogen oxide had reduced to zero, whereas the amount of nitrogen formed had reached a maximum. This may be explained by simultaneous chemical and radiolytic reactions leading to the formation of dinitrogen oxide and nitrogen and photolytic fission of dinitrogen oxide. Addition of sodium nitrite resulted in the rapid formation of dinitrogen oxide. The rate of hydrogen production was not changed significantly after the addition of hydrazine or nitrite. The results indicate that under normal operating conditions no dangerous hydrogen radiolysis yields should develop in the course of reprocessing and high-level liquid waste tank storage. Organic entrainment may lead to enhanced radiolytic decomposition and thus to considerable hydrogen production rates and pressure build-up in closed systems. (author)

  5. Measurement of sulphur-35 in the coolant gas of the Windscale Advanced Gas-Cooled Reactor

    International Nuclear Information System (INIS)

    Sandalls, F.J.

    1978-03-01

    Sulphur is an important element in some food chains and the release of radioactive sulphur to the environment must be closely controlled if the chemical form is such that it is available or potentially available for entering food chains. The presence of sulphur-35 in the coolant gas of the Windscale Advanced Gas-Cooled Reactor warranted a study to assess the quantity and chemical form of the radioactive sulphur in order to estimate the magnitude of the potential environmental hazard which might arise from the release of coolant gas from Civil Advanced Gas-Cooled Reactors. A combination of gas chromatographic and radiochemical analyses revealed carbonyl sulphide to be the only sulphur-35 compound present in the coolant gas of the Windscale Reactor. The concentration of carbonyl sulphide was found to lie in the range 40 to 100 x 10 -9 parts by volume and the sulphur-35 specific activity was about 20 mCi per gramme. The analytical techniques are described in detail. The sulphur-35 appears to be derived from the sulphur and chlorine impurities in the graphite. A method for the preparation of carbonyl sulphide labelled with sulphur-35 is described. (author)

  6. A rapid, solid phase extraction (SPE technique for the extraction and gas chromatographic determination lindane pesticide residue in tissue and milk

    Directory of Open Access Journals (Sweden)

    Yuningsih

    2006-03-01

    Full Text Available Organochlorine pesticide contamination in feed can cause residue in animal product (tissue and milk, so its become a problem in food safety. Solid phase extraction (SPE has been carried out for determination organochlorine pesticide residues in food animal production. The technique was rapid, not costly and produce limited amount of hazardous-waste. Samples were homogenized with acetonitrile trough cartridge C18, eluted in fluorocyl column with 2% ether-petroleum or acetonitrile fortissue and milk samples respectively. The recoveries of tissue sample by addition lindane standard solution: 0.50 and 1.00 μg are 85.10 and 103.10% respectively, while that of milk with the addition of 0.50, 1.00 and 1.50 μg are 83.80, 88.69 and 91.24% respectively. Three replicates were carried out for every sample. According of validation criteria of FAO/IAEA the recovery for analysis of pesticide residues was 70-110%. Therefore, the method is applicable.

  7. High-pressure liquid chromatographic assay of Bay n 7133 in human serum.

    OpenAIRE

    Fasching, C E; Hughes, C E; Hector, R F; Peterson, L R

    1984-01-01

    A high-pressure liquid chromatographic method that includes a Sep-Pak (Waters Associates, Inc., Milford , Mass.) preparation of human serum was employed for the quantitative assay of Bay n 7133. Drug levels of 0.1 to 20 micrograms/ml could be detected. No interference from amphotericin B was found in the chromatographic analysis of Bay n 7133.

  8. Assessment of oil weathering by gas chromatography-mass spectrometry, time warping and principal component analysis

    DEFF Research Database (Denmark)

    Malmquist, Linus M.V.; Olsen, Rasmus R.; Hansen, Asger B.

    2007-01-01

    weathering state and to distinguish between various weathering processes is investigated and discussed. The method is based on comprehensive and objective chromatographic data processing followed by principal component analysis (PCA) of concatenated sections of gas chromatography–mass spectrometry...

  9. Chromatographic generator systems for the actinides and natural decay series elements

    International Nuclear Information System (INIS)

    McAlister, D.R.; Horwitz, E.P.

    2011-01-01

    This work describes chromatographic radionuclide generator systems for the production of actinides and natural decay series elements. The generator systems begin with alpha emitting parent radioisotopes with half-lives (T 1/2 ) of greater than one year and produce alpha or beta emitting radioisotopes with half-lives of hours to days. Chromatographic systems were chosen to minimize radiolytic damage to chromatographic supports, preserve the parent activity for repeated use, provide high purity daughter radionuclide tracers, and to minimize or eliminate the need for evaporation of solutions of the parent or daughter nuclides. Useful secondary separations involving the daughters of the initial parent radionuclide are also described. Separation systems for 210 Bi, 210 Po, 211 Pb, 212 Pb, 223 Ra, 224 Ra, 225 Ra, 225 Ac, 227 Th, 228 Th, 231 Th, 234 Th, and 239 Np are outlined in detail. (orig.)

  10. Chromatographic background drift correction coupled with parallel factor analysis to resolve coelution problems in three-dimensional chromatographic data: quantification of eleven antibiotics in tap water samples by high-performance liquid chromatography coupled with a diode array detector.

    Science.gov (United States)

    Yu, Yong-Jie; Wu, Hai-Long; Fu, Hai-Yan; Zhao, Juan; Li, Yuan-Na; Li, Shu-Fang; Kang, Chao; Yu, Ru-Qin

    2013-08-09

    Chromatographic background drift correction has been an important field of research in chromatographic analysis. In the present work, orthogonal spectral space projection for background drift correction of three-dimensional chromatographic data was described in detail and combined with parallel factor analysis (PARAFAC) to resolve overlapped chromatographic peaks and obtain the second-order advantage. This strategy was verified by simulated chromatographic data and afforded significant improvement in quantitative results. Finally, this strategy was successfully utilized to quantify eleven antibiotics in tap water samples. Compared with the traditional methodology of introducing excessive factors for the PARAFAC model to eliminate the effect of background drift, clear improvement in the quantitative performance of PARAFAC was observed after background drift correction by orthogonal spectral space projection. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. Industrial scale chromatographic separation of valuable compounds from biomass hydrolysates and side streams

    Energy Technology Data Exchange (ETDEWEB)

    Saari, P.

    2011-06-15

    Carbohydrates are composed of a number of various monosaccharides, glucose being the most abundant. Some of the monosaccharides are valuable compounds used in the food and pharmaceutical industries. They can be separated from biomass hydrolysates e.g. by chromatographic methods. In this thesis, chromatographic separation of valuable compounds using ion exchange resins was studied on an industrial scale. Of special interest were rare monosaccharides in biomass hydrolysates. A novel chromatographic separation process was developed for fucose, starting from pre-processed spent sulfite liquor. The core of the process consists of three chromatographic separations with different types of ion exchange resins. Chromatographic separation of galactose was tested with three biomass hydrolysates; lactose, gum arabic and hemicellulose hydrolysates. It was demonstrated that also galactose can be separated from complex carbohydrate mixtures. A recovery process for arabinose from citrus pectin liquid residual and for mannose from wood pulp hydrolysate were also developed and experimentally verified. In addition to monosaccharides, chromatographic separation of glycinebetaine from vinasse was examined with a hydrogen form weak acid cation exchange resin. The separation involves untypical peak formation depending, for example, on the pH and the cation composition. The retention mechanism was found to be hydrogen bonding between glycinebetaine and the resin. In the experimental part, all four resin types - strong acid cation, strong base anion, weak acid cation and weak base anion exchange resins - were used. In addition, adsorption equilibria data of seven monosaccharides and sucrose were measured with the resins in sodium and sulfate forms because such data have been lacking. It was found out that the isotherms of all sugars were linear under industrial conditions. A systematic method for conceptual process design and sequencing of chromatographic separation steps were developed

  12. Gas chromatography with simultaneous detection: Ultraviolet spectroscopy, flame ionization, and mass spectrometry.

    Science.gov (United States)

    Gras, Ronda; Luong, Jim; Haddad, Paul R; Shellie, Robert A

    2018-05-08

    An effective analytical strategy was developed and implemented to exploit the synergy derived from three different detector classes for gas chromatography, namely ultraviolet spectroscopy, flame ionization, and mass spectrometry for volatile compound analysis. This strategy was achieved by successfully hyphenating a user-selectable multi-wavelength diode array detector featuring a positive temperature coefficient thermistor as an isothermal heater to a gas chromatograph. By exploiting the non-destructive nature of the diode array detector, the effluent from the detector was split to two parallel detectors; namely a quadrupole mass spectrometer and a flame ionization detector. This multi-hyphenated configuration with the use of three detectors is a powerful approach not only for selective detection enhancement but also for improvement in structural elucidation of volatile compounds where fewer fragments can be obtained or for isomeric compound analysis. With the diode array detector capable of generating high resolution gas phase spectra, the information collected provides useful confirmatory information without a total dependence on the chromatographic separation process which is based on retention time. This information-rich approach to chromatography is achieved without incurring extra analytical time, resulting in improvements in compound identification accuracy, analytical productivity, and cost. Chromatographic performance obtained from model compounds was found to be acceptable with a relative standard deviation of the retention times of less than 0.01% RSD, and a repeatability at two levels of concentration of 100 and 1000 ppm (v/v) of less than 5% (n = 10). With this configuration, correlation of data between the three detectors was simplified by having near identical retention times for the analytes studied. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Chromatographic separation of low-temperature tar. Part II

    Energy Technology Data Exchange (ETDEWEB)

    Terres, E; Gebert, F; Huelsemann, H; Petereit, H; Toepsch, H; Ruppert, W

    1955-01-01

    Chromatographic methods and apparatus are discussed. The Folin-Denis reagent (Na tungstate molybdate in H/sub 3/PO/sub 4/) is used for developing paper chromatograms of phenol mixtures. Other reagents are given.

  14. DEVELOPMENT OF NOVEL CERAMIC NANOFILM-FIBER INTEGRATED OPTICAL SENSORS FOR RAPID DETECTION OF COAL DERIVED SYNTHESIS GAS

    Energy Technology Data Exchange (ETDEWEB)

    Junhang Dong; Hai Xiao; Xiling Tang; Hongmin Jiang; Kurtis Remmel; Amardeep Kaur

    2012-09-30

    The overall goal of this project is to conduct fundamental studies on advanced ceramic materials and fiber optic devices for developing new types of high temperature (>500{degree}C) fiber optic chemical sensors (FOCS) for monitoring fossil (mainly coal) and biomass derived gases in power plants. The primary technical objective is to investigate and demonstrate the nanocrystalline doped-ceramic thin film enabled FOCS that possess desired stability, sensitivity and selectivity for in-situ, rapid gas detection in the syngas streams from gasification and combustion flue gases. This report summarizes research works of two integrated parts: (1) development of metal oxide solid thin films as sensing materials for detection and measurement of important gas components relevant to the coal- and biomass-derived syngas and combustion gas streams at high temperatures; and (2) development of fiber optic devices that are potentially useful for constructing FOCS in combination with the solid oxide thin films identified in this program.

  15. Chromatographic determination of silicon and phosphorus as molybdic heteropoly acids with preconcentration

    International Nuclear Information System (INIS)

    Tikhomirova, T.I.; Krokhin, O.V.; Dubovik, D.B.; Ivanov, A.V.; Shpigun, O.A.

    2002-01-01

    Chromatographic behaviour of silicon and phosphorus as molybdic heteropoly acids with preconcentration as ion associations of heteropoly acid with tributylammonium bromide was studied. The technique of simultaneous analysis of silicon and phosphorus was developed. During investigation into the effect of acetonitril content in the probe on the form of chromatographic peak of molybdosilicic acid the negative influence of acetonitril on the form of peak was ascertained. This effect may be eliminated by the lowering of acetonitril content up to 50 %. It was found that under these conditions the chromatographic peak practically was absent, because of the heteropoly acid of the Mo(VI) abundance transformed in the MoO 2 2+ cation form without reaction with tributylammonium cation during concentration of heteropoly acid [ru

  16. Analysis of s-triazine herbicides in model systems and samples of groundwater by gas and liquid chromatography

    Directory of Open Access Journals (Sweden)

    Kostadinović Ljiljana

    2010-01-01

    Full Text Available In this paper, residues of s-triazine herbicides (Simazine, Atrazine, Amethrine, Promethrine and Azyprothrine have been determined in samples of model systems and real groundwater samples by gas-chromatography and high performance liquid chromatography. S-triazine herbicides were isolated from water samples by chloroform-methanol mixture (1:1, followed by purification of extract on the Al2O3 column. Gas-chromatographic determination the residues of s-triazines is performed on parallel capilar columns ULTRA I and ULTRA II, using specific NP detector. Liquid-chromatographic determination the s-triazines was performed on the column TSK ODS-120 A 5 mm 'LKB', using the mobile phase methanol-water (60:40. Total concentration of s-triazines in samples of Danube water was 3.54 mg dm-3. .

  17. Identification of di(ethylhexyl) phthalate as impurity in the analysis by using chromatography gas tandem mass spectrometry

    Science.gov (United States)

    Pusfitasari, Eka Dian; Hendarsyah, Hendris; Salahuddin, Ariani, Novita

    2017-01-01

    Di(ethylhexyl) phthalate (DEHP) is a plasticizer commonly used in plastics. Physically DEHP has a low vapor pressure. DEHP can seep into the liquid in direct contact with the plastic wrapping materials, and typically can occur rapidly if extractable into food or non-polar solvents, such as oil, once the food is packaged in PVC packaging materials. DEHP has been analyzed by using gas chromatography which has a high sensitivity level. If the equipment used for the analysis is made from plastic containing DEHP, then it may be possible that DEHP can be extracted and appear on the outcome of the injection. It can interfere with the process of analysis, especially for the analysis of food samples. This study has identified the present of DEHP in the blank injection performed by Gas Chromatography tandem Mass Spectrometry with Selected Ion Monitoring mode (SIM). Researchers are required to verify whether the gas chromatographic system used is ready for the analysis process. In addition, the comparison and calculation of the intensity of the ion fragmentation spectra generated by mass spectrometry detector can be used for the qualitative determination to ensure the presence of the target compound. In this study is also discussed the differences between the high-intensity fragmentation of DEHP and dioctyl phthalate (DOP).

  18. Liquid chromatography and supercritical fluid chromatography as alternative techniques to gas chromatography for the rapid screening of anabolic agents in urine.

    Science.gov (United States)

    Desfontaine, Vincent; Nováková, Lucie; Ponzetto, Federico; Nicoli, Raul; Saugy, Martial; Veuthey, Jean-Luc; Guillarme, Davy

    2016-06-17

    This work describes the development of two methods involving supported liquid extraction (SLE) sample treatment followed by ultra-high performance liquid chromatography or ultra-high performance supercritical fluid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS and UHPSFC-MS/MS) for the screening of 43 anabolic agents in human urine. After evaluating different stationary phases, a polar-embedded C18 and a diol columns were selected for UHPLC-MS/MS and UHPSFC-MS/MS, respectively. Sample preparation, mobile phases and MS conditions were also finely tuned to achieve highest selectivity, chromatographic resolution and sensitivity. Then, the performance of these two methods was compared to the reference routine procedure for steroid analyses in anti-doping laboratories, which combines liquid-liquid extraction (LLE) followed by gas chromatography coupled to tandem mass spectrometry (GC-MS/MS). For this purpose, urine samples spiked with the compounds of interest at five different concentrations were analyzed using the three analytical platforms. The retention and selectivity of the three techniques were very different, ensuring a good complementarity. However, the two new methods displayed numerous advantages. The overall procedure was much faster thanks to high throughput SLE sample treatment using 48-well plates and faster chromatographic analysis. Moreover, the highest sensitivity was attained using UHPLC-MS/MS with 98% of the doping agents detected at the lowest concentration level (0.1ng/mL), against 76% for UHPSFC-MS/MS and only 14% for GC-MS/MS. Finally, the weakest matrix effects were obtained with UHPSFC-MS/MS with 76% of the analytes displaying relative matrix effect between -20 and 20%, while the GC-MS/MS reference method displayed very strong matrix effects (over 100%) for all of the anabolic agents. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Chromatographic characterisation, in vitro antioxidant and free ...

    African Journals Online (AJOL)

    Chromatographic fractionation and spectroscopic analysis of the ME4 fraction revealed the presence of four compounds namely garcinia biflavonoids GB1 and GB2, garcinal and garcinoic acid. These findings show that these four compounds are partly responsible for the great antioxidant potential of G. kola seeds.

  20. Measuring Trace Hydrocarbons in Silanes

    Science.gov (United States)

    Lesser, L. A.

    1984-01-01

    Technique rapid and uses standard analytical equipment. Silane gas containing traces of hydrocarbons injected into carrier gas of moist nitrogen having about 0.2 percent water vapor. Carrier, water and silane pass through short column packed with powdered sodium hydroxide which combines moisture and silane to form nonvolatile sodium silicate. Carrier gas free of silane but containing nonreactive hydrocarbons, pass to silica-gel column where chromatographic separation takes place. Hydrocarbons measured by FID.

  1. [A peak recognition algorithm designed for chromatographic peaks of transformer oil].

    Science.gov (United States)

    Ou, Linjun; Cao, Jian

    2014-09-01

    In the field of the chromatographic peak identification of the transformer oil, the traditional first-order derivative requires slope threshold to achieve peak identification. In terms of its shortcomings of low automation and easy distortion, the first-order derivative method was improved by applying the moving average iterative method and the normalized analysis techniques to identify the peaks. Accurate identification of the chromatographic peaks was realized through using multiple iterations of the moving average of signal curves and square wave curves to determine the optimal value of the normalized peak identification parameters, combined with the absolute peak retention times and peak window. The experimental results show that this algorithm can accurately identify the peaks and is not sensitive to the noise, the chromatographic peak width or the peak shape changes. It has strong adaptability to meet the on-site requirements of online monitoring devices of dissolved gases in transformer oil.

  2. A Pilot Stability Study of Dehydroepiandrosterone Rapid-dissolving Tablets Prepared by Extemporaneous Compounding.

    Science.gov (United States)

    Rush, Steven D; Vernak, Charlene; Zhao, Fang

    2017-01-01

    Dehydroepiandrosterone supplementation is used to treat a variety of conditions. Rapid-dissolving tablets are a relatively novel choice for compounded dehydroepiandrosterone dosage forms. While rapid-dissolving tablets offer ease of administration, there are uncertainties about the physical and chemical stability of the drug and dosage form during preparation and over long-term storage. This study was designed to evaluate the stability of dehydroepiandrosterone rapid-dissolving tablets just after preparation and over six months of storage. The Professional Compounding Centers of America rapid-dissolving tablet mold and base formula were used to prepare 10-mg strength dehydroepiandrosterone rapid-dissolving tablets. The formulation was heated at 100°C to 110°C for 30 minutes, released from the mold, and cooled at room temperature for 30 minutes. The resulting rapid-dissolving tablets were individually packaged in amber blister packs and stored in a stability chamber maintained at 25°C and 60% relative humidity. The stability samples were pulled at pre-determined time points for evaluation, which included visual inspection, tablet weight check, United States Pharmacopeia disintegration test, and stability-indicating high-performance liquid chromatography. The freshly prepared dehydroepiandrosterone rapiddissolving tablets exhibited satisfactory chemical and physical stability. Time 0 samples disintegrated within 40 seconds in water kept at 37°C. The high-performance liquid chromatographic results confirmed that the initial potency was 101.9% of label claim and that there was no chemical degradation from the heating procedure. Over six months of storage, there were no significant changes in visual appearance, physical integrity, or disintegration time for any of the stability samples. The high-performance liquid chromatographic results also indicated that dehydroepiandrosterone rapid-dissolving tablets retained >95% label claim with no detectable degradation

  3. Multiple responses optimization in the development of a headspace gas chromatography method for the determination of residual solvents in pharmaceuticals

    Directory of Open Access Journals (Sweden)

    Carla M. Teglia

    2015-10-01

    Full Text Available An efficient generic static headspace gas chromatography (HSGC method was developed, optimized and validated for the routine determination of several residual solvents (RS in drug substance, using a strategy with two sets of calibration. Dimethylsulfoxide (DMSO was selected as the sample diluent and internal standards were used to minimize signal variations due to the preparative step. A gas chromatograph from Agilent Model 6890 equipped with flame ionization detector (FID and a DB-624 (30 m×0.53 mm i.d., 3.00 µm film thickness column was used. The inlet split ratio was 5:1. The influencing factors in the chromatographic separation of the analytes were determined through a fractional factorial experimental design. Significant variables: the initial temperature (IT, the final temperature (FT of the oven and the carrier gas flow rate (F were optimized using a central composite design. Response transformation and desirability function were applied to find out the optimal combination of the chromatographic variables to achieve an adequate resolution of the analytes and short analysis time. These conditions were 30 °C for IT, 158 °C for FT and 1.90 mL/min for F. The method was proven to be accurate, linear in a wide range and very sensitive for the analyzed solvents through a comprehensive validation according to the ICH guidelines. Keywords: Headspace gas chromatography, Residual solvents, Pharmaceuticals, Surface response methodology, Desirability function

  4. Determination of 21 trace impurities in UO2 with tributyl phosphate chromatographic separation-USN-inductively coupled/atomic emission spectrometric

    International Nuclear Information System (INIS)

    Hou Lieqi; Wang Shuan; Li Jie

    1996-03-01

    A method of tributyl phosphate chromatographic separation-USN-inductively coupled/atomic emission spectrometric was selected. And the parameters, interference of acid concentrations, interference of coexisting elements, selecting of flow for carrier gas, solution temperature were studied. When the sampling amount is 250 mg, the determination range for Al, Ag, Ba, Ca, Cd, Co, Cr, Cu, Fe, In, Li, Mg, Mn, Mo, Ni, Pb, Sn, Ti, V, Y and Zn are 0.2∼100 ng· -1 , recovery are 94%∼110%. The RSD (n 8) are 0.8%∼6.2%. (3 refs., 4 tabs.)

  5. Determination of adsorption isotherms of chlorinated hydrocarbons on halloysite adsorbent by inverse gas chromatography.

    Science.gov (United States)

    Czech, K; Słomkiewicz, P M

    2013-05-03

    Inverse gas chromatographic methods of isotherm determination peak maximum (PM) and peak division (PD) were compared. These methods were applied to determine adsorption isotherms of dichloroethylene, trichloroethylene and tetrachloroethylene on acid-activated halloysite and adsorption enthalpy. Copyright © 2013 Elsevier B.V. All rights reserved.

  6. On-line Automated Sample Preparation-Capillary Gas Chromatography for the Analysis of Plasma Samples.

    NARCIS (Netherlands)

    Louter, A.J.H.; van der Wagt, R.A.C.A.; Brinkman, U.A.T.

    1995-01-01

    An automated sample preparation module, (the automated sample preparation with extraction columns, ASPEC), was interfaced with a capillary gas chromatograph (GC) by means of an on-column interface. The system was optimised for the determination of the antidepressant trazodone in plasma. The clean-up

  7. Validated high performance liquid chromatographic (HPLC) method ...

    African Journals Online (AJOL)

    STORAGESEVER

    2010-02-22

    Feb 22, 2010 ... specific and accurate high performance liquid chromatographic method for determination of ZER in micro-volumes ... tional medicine as a cure for swelling, sores, loss of appetite and ... Receptor Activator for Nuclear Factor κ B Ligand .... The effect of ... be suitable for preclinical pharmacokinetic studies. The.

  8. Method Development for the Determination of Fluorotelomer Alcohols in Soils by Gas Chromatography Mass Spectrometry

    Science.gov (United States)

    Fluorotelomer alcohols (FTOHs) have been widely studied as precursors to perfluorocarboxylates, e.g. 8:2 FTOH degrades to perfluorooctanoic acid (PFOA). This presentation describes an analytical method for the extraction and analysis of 6:2, 8:2, and 10:2 FTOHs. Gas chromatograph...

  9. Investigation of parameters affecting the online combination of supercritical fluid extraction with capillary gas chromatography

    NARCIS (Netherlands)

    Lou, X.W.; Janssen, J.G.M.; Cramers, C.A.M.G.

    1996-01-01

    Two different injectors, a split/splitless injector and a programmed temperature vaporizer (PTV) injector were investigated as the interface in on-line supercritical fluid extraction (SFE)-capillary gas chromatography (cGC). The parameters affecting the chromatographic peak shapes as well as the

  10. An analytical study by gas liquid chromatography and radiochromatography of tritium labelled lebaycid; Estudio Analitico del proceso de sistesis del lebaycid marcado contritio por cromatogria gas liquido y radiocromatografia

    Energy Technology Data Exchange (ETDEWEB)

    Perez Garcia, M M

    1969-07-01

    The stability and purity of the syntheses products of Lebaycid: 0,0 dime thylfosfochlorothionate and 4 methyl-thio-m-cresol were investigated by gas liquid chromatography. The study on (CH{sub 3}O){sub 2} PSC1 was made in a column of Silicone SE-30, Reoplex 400 using a thermal conductivity detector. The 99,4% pure product obtained from the preparative gas chromatograph was found to be stable within the duration of the experiment: seven months. (Author) 23 refs.

  11. A simple method for the measurement of radioactivity of samples separated by gas chromatography

    International Nuclear Information System (INIS)

    Farkas, T.

    1981-01-01

    Gas chromatographs with flame ionization detector can be used to determine the radioactivity ( 14 C) of separated peaks. After a suitable change in the detector output the combustion product 14 CO 2 can be trapped by hyamine hydroxyde and measured by liquid scintigraphy. 90% of peak activity can be collected and measured, thus the method can be applied to determine the distribution and specific radioactivity of the components separated by gas chromatography. (author)

  12. Determination of carboxyl groups in wood fibers by headspace gas chromatography

    Science.gov (United States)

    X.-S. Chai; Q.X. Hou; J.Y. Zhu; S.-L. Chen; S.F. Wang; L. Lucia

    2003-01-01

    The phase reaction conversion (PRC) headspace gas chromatographic (HSGC) technique was employed to develop a method for the determination of the content of carboxyl groups in wood fibers. Acid treatment of the wood fibers using hydrochloric was applied to convert carboxyl groups to carboxyl acids. Bicarbonate solution is then used to react with carboxyl acids on the...

  13. Monitoring of trace chloride ions at different stages of the gas production process

    Directory of Open Access Journals (Sweden)

    A.Y. El Naggar

    2015-01-01

    Full Text Available Fifty gas and liquid samples at different stages of Obaiyed gas plant in Egypt were selected and subjected for determining chloride ion and hydrocarbon compositions. The trace levels of chloride in the water extracted from natural gas, condensate, Benfield and glycol samples were achieved using ion chromatograph (IC, electrical, conductivity and potentiometric methods, respectively. The hydrocarbon compositions were analyzed and evaluated using capillary gas chromatography. The chloride ions in natural gas and condensate are a function of water content and their concentration mainly depends on the separation efficiency. Variability in natural gas and condensate compositions seasonally is not an uncommon occurrence. Our aim is monitoring of chloride ion to select and optimize the conditions of sweetening and dehydration regenerators in order to follow and prevent their gradient in gas plant.

  14. Alternative chromatographic system for the quality control of lipophilic technetium-99m radiopharmaceuticals such as [{sup 99m}Tc(MIBI){sub 6}]{sup +}

    Energy Technology Data Exchange (ETDEWEB)

    Faria, D.P.; Buchpiguel, C.A.; Marques, F.L.N., E-mail: danielefaria1@gmail.com [Universidade de Sao Paulo (USP), Sao Paulo, SP (Brazil). Faculdade de Medicina. Departamento de Radiologia. Servico de Medicina Nuclear

    2015-10-15

    Knowledge of the radiochemical purity of radiopharmaceuticals is mandatory and can be evaluated by several methods and techniques. Planar chromatography is the technique normally employed in nuclear medicine since it is simple, rapid and usually of low cost. There is no standard system for the chromatographic technique, but price, separation efficiency and short time for execution must be considered. We have studied an alternative system using common chromatographic stationary phase and alcohol or alcohol:chloroform mixtures as the mobile phase, using the lipophilic radiopharmaceutical [{sup 99m}Tc(MIBI){sub 6}]{sup +} as a model. Whatman 1 modified phase paper and absolute ethanol, Whatman 1 paper and methanol: chloroform (25:75), Whatman 3MM paper and ethanol:chloroform (25:75), and the more expensive ITLC-SG and 1-propanol: chloroform (10:90) were suitable systems for the direct determination of radiochemical purity of [{sup 99m}Tc(MIBI){sub 6}]{sup +} since impurities such as {sup 99m}Tc-reduced-hydrolyzed (RH), {sup 99m}TcO4{sup -} and [{sup 99m}Tc(cysteine){sub 2}]{sup -} complex were completely separated from the radiopharmaceutical, which moved toward the front of chromatographic systems while impurities were retained at the origin. The time required for analysis was 4 to 15 min, which is appropriate for nuclear medicine routines. (author)

  15. Influence of column type and chromatographic conditions on the ion-exchange chromatography of immunoglobulins.

    Science.gov (United States)

    Yang, Y B; Harrison, K

    1996-08-30

    Immunoglobulins are often purified by affinity chromatography. However, this technique is costly, can result in poor resolution for subclasses (or is only group specific), and leads to possible leaching of contaminants into the purified products. Ion-exchange chromatography has shown great potential and has found an increased usage in the purification of immunoglobulins. The aim of this study is to further understand the separation mechanism with emphasis on the influence of column type and chromatographic conditions on the peak shape, selectivity and changes in the elution patterns. Included are strong cation-exchange, strong anion-exchange and weak anion-exchange columns. Five immunoglobulin G antibodies were used as test probes. Some sera and ascites were also used in the study. Among the chromatographic conditions examined were mobile phase pH, buffer type, buffer concentration, gradient rate, and column temperature. Significant differences in the chromatographic behavior (elution pattern, peak shape and selectivity) of the test samples are discussed in regard to the column type and the chromatographic conditions.

  16. Development of liquid chromatographic methods for the determination of phytosterols in Standard Reference Materials containing saw palmetto.

    Science.gov (United States)

    Bedner, Mary; Schantz, Michele M; Sander, Lane C; Sharpless, Katherine E

    2008-05-23

    Liquid chromatographic (LC) methods using atmospheric pressure chemical ionization/mass spectrometric (APCI-MS) detection were developed for the separation and analysis of the phytosterols campesterol, cycloartenol, lupenone, lupeol, beta-sitosterol, and stigmasterol. Brassicasterol and cholesterol were also included for investigation as internal standards. The methods were used to identify and quantify the phytosterols in each of two Serenoa repens (saw palmetto) Standard Reference Materials (SRMs) developed by the National Institute of Standards and Technology (NIST). Values obtained by LC-MS were compared to those obtained using the more traditional approach of gas chromatography with flame ionization detection. This is the first reported use of LC-MS to determine phytosterols in saw palmetto dietary supplement materials.

  17. Paper chromatographic behavior of tetranitronitrosylruthenate and its decomposition products

    International Nuclear Information System (INIS)

    Akatsu, Eiko

    1981-01-01

    The paper chromatographic behavior of tetranitronitrosylruthenate was examined together with its decomposition products. First, Rf values at various eluting conditions were studied with five kinds of papers, since there was a discrepancy among the reported Rf values. Usually Rf of 0.9 was obtained by the recommended procedure of Wain, et al. Second, stability of the tetranitrosylruthenate in water was followed by paper chromatography. No change was found until 200 days passed. Third, the tetranitronitrosylruthenate was warmed in acid, and its decomposition products were studied through the paper chromatography. The paper chromatographic behavior showed that the sample kept in water more than 200 days seemed to contain a dinitro complex, and the sample warmed in acid seemed to be decomposed to a mononitro complex of further. (author)

  18. Exploring Blueberry Aroma Complexity by Chromatographic and Direct-Injection Spectrometric Techniques.

    Science.gov (United States)

    Farneti, Brian; Khomenko, Iuliia; Grisenti, Marcella; Ajelli, Matteo; Betta, Emanuela; Algarra, Alberto Alarcon; Cappellin, Luca; Aprea, Eugenio; Gasperi, Flavia; Biasioli, Franco; Giongo, Lara

    2017-01-01

    , and esters that can be used as putative biomarkers to rapidly evaluate the blueberry aroma variations related to ripening and/or senescence as well as to genetic background differences. Moreover, the obtained results demonstrated the complementarity between chromatographic and direct-injection mass spectrometric techniques to study the blueberry aroma.

  19. Determination of boiling point of petrochemicals by gas chromatography-mass spectrometry and multivariate regression analysis of structural activity relationship.

    Science.gov (United States)

    Fakayode, Sayo O; Mitchell, Breanna S; Pollard, David A

    2014-08-01

    Accurate understanding of analyte boiling points (BP) is of critical importance in gas chromatographic (GC) separation and crude oil refinery operation in petrochemical industries. This study reported the first combined use of GC separation and partial-least-square (PLS1) multivariate regression analysis of petrochemical structural activity relationship (SAR) for accurate BP determination of two commercially available (D3710 and MA VHP) calibration gas mix samples. The results of the BP determination using PLS1 multivariate regression were further compared with the results of traditional simulated distillation method of BP determination. The developed PLS1 regression was able to correctly predict analytes BP in D3710 and MA VHP calibration gas mix samples, with a root-mean-square-%-relative-error (RMS%RE) of 6.4%, and 10.8% respectively. In contrast, the overall RMS%RE of 32.9% and 40.4%, respectively obtained for BP determination in D3710 and MA VHP using a traditional simulated distillation method were approximately four times larger than the corresponding RMS%RE of BP prediction using MRA, demonstrating the better predictive ability of MRA. The reported method is rapid, robust, and promising, and can be potentially used routinely for fast analysis, pattern recognition, and analyte BP determination in petrochemical industries. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. A chromatographic determination of water in non-aqueous phases of solvent extraction systems

    International Nuclear Information System (INIS)

    Lyle, S.J.; Smith, D.B.

    1975-01-01

    The disadvantages of the Karl Fischer method for the determination of water in the non-aqueous phases of solvent extraction systems are pointed out, and a gas chromatographic method is described which is claimed to be potentially capable of overcoming these disadvantages. The method, as described, was developed to satisfy conditions relevant to measurement of the transfer rate of water from an aqueous phase into tri-n-butylphosphate in toluene, but it can be used for water determination in other solvent extraction systems. The apparatus used is described in detail. The concentration of water in water-saturated TBP was found to be 3.56 mol/litre, compared with a value of 3.55 obtained by Karl Fischer titration and previous literature values of 3.59 and 3.57. Measurements of water content in benzene solutions of long chain alkylamines were also sucessfully carried out. (U.K.)

  1. Correlations between chromatographic parameters and bioactivity predictors of potential herbicides.

    Science.gov (United States)

    Janicka, Małgorzata

    2014-08-01

    Different liquid chromatography techniques, including reversed-phase liquid chromatography on Purosphere RP-18e, IAM.PC.DD2 and Cosmosil Cholester columns and micellar liqud chromatography with a Purosphere RP-8e column and using buffered sodium dodecyl sulfate-acetonitrile as the mobile phase, were applied to study the lipophilic properties of 15 newly synthesized phenoxyacetic and carbamic acid derivatives, which are potential herbicides. Chromatographic lipophilicity descriptors were used to extrapolate log k parameters (log kw and log km) and log k values. Partitioning lipophilicity descriptors, i.e., log P coefficients in an n-octanol-water system, were computed from the molecular structures of the tested compounds. Bioactivity descriptors, including partition coefficients in a water-plant cuticle system and water-human serum albumin and coefficients for human skin partition and permeation were calculated in silico by ACD/ADME software using the linear solvation energy relationship of Abraham. Principal component analysis was applied to describe similarities between various chromatographic and partitioning lipophilicities. Highly significant, predictive linear relationships were found between chromatographic parameters and bioactivity descriptors. © The Author [2013]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  2. Total cholesterol in serum determined by isotope dilution/mass spectrometry, with liquid-chromatographic separation

    International Nuclear Information System (INIS)

    Takatsu, Akiko; Nishi, Sueo

    1988-01-01

    We describe an accurate, precise method for determination of total serum cholesterol by isotope dilution/mass spectrometry (IDMS) with liquid chromatographic separation. After adding [3,4- 13 C] cholesterol to serum and hydrolyzing the cholesterol esters, we extract the total cholesterol. High-performance liquid chromatography (HPLC) is used to separate the extracted cholesterol for measurement by electron-impact mass spectrometry with use of a direct-insertion device. To evaluate the specificity and the accuracy of this method, we also studied the conventional IDMS method, which involves converting cholesterol to the trimethylsilyl ether and assay by gas chromatography-mass spectrometry with use of a capillary column. The coefficient of variation for the HPLC method was a little larger than for the conventional method, but mean values by each method agreed within 1% for all sera tested. (author)

  3. Supercritical Fluid Chromatographic Separation of Dimethylpolysiloxane Polymer

    Energy Technology Data Exchange (ETDEWEB)

    Pyo, Dong Jin; Lim, Chang Hyun [Kangwon National University, Chuncheon (Korea, Republic of)

    2005-02-15

    Water was used as a polar modifier and a μ-porasil column as a saturator column. The μ-porasil column was inserted between the pump outlet and the injection valve. During the passage of the supercritical fluid mobile phase through the silica column, a polar modifier (water) can be dissolved in the pressurized supercritical fluid. Dimethylpolysiloxane polymer has been known as more polar polymer than polystyrene polymer. Dimethylpolysiloxane polymer has never been separated using water modified mobile phase. In this paper, using a μ-porasil column as a saturator column, excellent supercritical fluid chromatograms of dimethylpolysiloxane oligomers were obtained. The use of compressed (dense) gases and supercritical fluids as chromatographic mobile phases in conjunction with liquid chromatographic (LC)-type packed columns was first reported by Klesper et al. in 1962. During its relatively short history, supercritical fluid chromatography (SFC) has become an attractive alternative to GC and LC in certain industrially important applications. SFC gives the advantage of high efficiency and allows the analysis of nonvolatile or thermally labile mixtures.

  4. Supercritical Fluid Chromatographic Separation of Dimethylpolysiloxane Polymer

    International Nuclear Information System (INIS)

    Pyo, Dong Jin; Lim, Chang Hyun

    2005-01-01

    Water was used as a polar modifier and a μ-porasil column as a saturator column. The μ-porasil column was inserted between the pump outlet and the injection valve. During the passage of the supercritical fluid mobile phase through the silica column, a polar modifier (water) can be dissolved in the pressurized supercritical fluid. Dimethylpolysiloxane polymer has been known as more polar polymer than polystyrene polymer. Dimethylpolysiloxane polymer has never been separated using water modified mobile phase. In this paper, using a μ-porasil column as a saturator column, excellent supercritical fluid chromatograms of dimethylpolysiloxane oligomers were obtained. The use of compressed (dense) gases and supercritical fluids as chromatographic mobile phases in conjunction with liquid chromatographic (LC)-type packed columns was first reported by Klesper et al. in 1962. During its relatively short history, supercritical fluid chromatography (SFC) has become an attractive alternative to GC and LC in certain industrially important applications. SFC gives the advantage of high efficiency and allows the analysis of nonvolatile or thermally labile mixtures

  5. Isotope exchange between gaseous hydrogen and uranium hydride powder

    International Nuclear Information System (INIS)

    Shugard, Andrew D.; Buffleben, George M.; Johnson, Terry A.; Robinson, David B.

    2014-01-01

    Highlights: • Isotope exchange between hydrogen gas and uranium hydride powder can be rapid and reversible. • Gas–solid exchange rate is controlled by transport within ∼0.7 μm hydride particles. • Gas chromatographic separation of hydrogen isotopes using uranium hydride is feasible. - Abstract: Isotope exchange between gaseous hydrogen and solid uranium hydride has been studied by flowing hydrogen (deuterium) gas through packed powder beds of uranium deuteride (hydride). We used a residual gas analyzer system to perform real-time analysis of the effluent gas composition. We also developed an exchange and transport model and, by fitting it to the experimental data, extracted kinetic parameters for the isotope exchange reaction. Our results suggest that, from approximately 70 to 700 kPa and 25 to 400 °C, the gas-to-solid exchange rate is controlled by hydrogen and deuterium transport within the ∼0.7 μm diameter uranium hydride particles. We use our kinetic parameters to show that gas chromatographic separation of hydrogen and deuterium using uranium hydride could be feasible

  6. Novel preconcentration technique for on-line coupling to high-speed narrow-bore capillary gas chromatography: sample enrichment by equilibrium (ab)sorption, I: Principles and theoretical aspects

    NARCIS (Netherlands)

    Pham Tuan, H.; Janssen, J.G.M.; Cramers, C.A.M.G.

    1997-01-01

    In recent years, there has been substantial progress in the field of high-speed narrow-bore capillary gas chromatography (GC) in general, and in the development of (trans)portable gas chromatographs for fast and accurate analysis in field applications in particular. Due to the limited

  7. Solid-phase microextraction for gas chromatographic/mass spectrometric analysis of dimethoate in human biological samples.

    Science.gov (United States)

    Gallardo, E; Barroso, M; Margalho, C; Cruz, A; Vieira, D N; López-Rivadulla, M

    2006-01-01

    A new, simple and rapid procedure for the determination of dimethoate in urine and blood samples was developed using direct immersion solid-phase microextraction and gas chromatography/mass spectrometry. This technique required only 0.1 mL of sample, and ethion was used as internal standard. Two types of coated fibre were compared (100 microm polydimethylsiloxane, and 65 microm Carbowax/divinylbenzene). Other parameters, such as extraction temperature, adsorption and desorption time, salt addition, agitation and pH, were optimized to enhance the sensitivity of the method. Limits of detection (LODs) and quantitation (LOQs) were 50 and 100 ng/mL for urine and 200 and 500 ng/mL for blood, respectively. The method was found to be linear between the LOQ and 40 microg/mL for urine, and between the LOQ and 50 microg/mL for blood, with correlation coefficients ranging from 0.9923-0.9996. Precision (intra- and interday) and accuracy were in conformity with the criteria normally accepted in bioanalytical method validation. The mean absolute recoveries of dimethoate were 1.24 and 0.50% for urine and blood, respectively. Because of its simplicity and the fact that small volumes of sample are used, the described method can be successfully used in the diagnosis of poisoning by this pesticide, namely in those situations where the sample volume is limited, as frequently occurs in forensic toxicology. Copyright 2006 John Wiley & Sons, Ltd.

  8. DEVELOPMENT OF A LOW COST INFERENTIAL NATURAL GAS ENERGY FLOW RATE PROTOTYPE RETROFIT MODULE

    Energy Technology Data Exchange (ETDEWEB)

    E. Kelner; D. George; T. Morrow; T. Owen; M. Nored; R. Burkey; A. Minachi

    2005-05-01

    In 1998, Southwest Research Institute began a multi-year project to develop a working prototype instrument module for natural gas energy measurement. The module will be used to retrofit a natural gas custody transfer flow meter for energy measurement, at a cost an order of magnitude lower than a gas chromatograph. Development and evaluation of the prototype energy meter in 2002-2003 included: (1) refinement of the algorithm used to infer properties of the natural gas stream, such as heating value; (2) evaluation of potential sensing technologies for nitrogen content, improvements in carbon dioxide measurements, and improvements in ultrasonic measurement technology and signal processing for improved speed of sound measurements; (3) design, fabrication and testing of a new prototype energy meter module incorporating these algorithm and sensor refinements; and (4) laboratory and field performance tests of the original and modified energy meter modules. Field tests of the original energy meter module have provided results in close agreement with an onsite gas chromatograph. The original algorithm has also been tested at a field site as a stand-alone application using measurements from in situ instruments, and has demonstrated its usefulness as a diagnostic tool. The algorithm has been revised to use measurement technologies existing in the module to measure the gas stream at multiple states and infer nitrogen content. The instrumentation module has also been modified to incorporate recent improvements in CO{sub 2} and sound speed sensing technology. Laboratory testing of the upgraded module has identified additional testing needed to attain the target accuracy in sound speed measurements and heating value.

  9. Liquid chromatographic-tandem mass spectrometric assay for ...

    African Journals Online (AJOL)

    Methods: Blood and urine samples were obtained from healthy volunteers who admitted to not being on any medications. The investigated analytes were chromatographically separated on a C18 column (Luna®-PFP 100Å column, 50 mm × 2.0 mm i.d., 3.0 μm) with the aid of a mobile phase containing A; acetonitrile (ACN) ...

  10. A simple subcritical chromatographic test for an extended ODS high performance liquid chromatography column classification.

    Science.gov (United States)

    Lesellier, Eric; Tchapla, Alain

    2005-12-23

    This paper describes a new test designed in subcritical fluid chromatography (SFC) to compare the commercial C18 stationary phase properties. This test provides, from a single analysis of carotenoid pigments, the absolute hydrophobicity, the silanol activity and the steric separation factor of the ODS stationary phases. Both the choice of the analytical conditions and the validation of the information obtained from the chromatographic measurements are detailed. Correlations of the carotenoid test results with results obtained from other tests (Tanaka, Engelhard, Sander and Wise) performed both in SFC and HPLC are discussed. Two separation factors, calculated from the retention of carotenoid pigments used as probe, allowed to draw a first classification diagram. Columns, which present identical chromatographic behaviors are located in the same area on this diagram. This location can be related to the stationary phase properties: endcapping treatments, bonding density, linkage functionality, specific area or silica pore diameter. From the first classification, eight groups of columns are distinguished. One group of polymer coated silica, three groups of polymeric octadecyl phases, depending on the pore size and the endcapping treatment, and four groups of monomeric stationary phases. An additional classification of the four monomeric groups allows the comparison of these stationary phases inside each group by using the total hydrophobicity. One hundred and twenty-nine columns were analysed by this simple and rapid test, which allows a comparison of columns with the aim of helping along their choice in HPLC.

  11. Development, modelling, optimisation and scale-up of chromatographic purification of a therapeutic protein

    DEFF Research Database (Denmark)

    Mollerup, Jørgen; Hansen, Thomas Budde; Kidal, Steffen

    2007-01-01

    Development of a chromatographic purification step proceeds through a number of stages. High-throughput screening techniques are used to identify suitable resins. This technique is also suitable for the design of a capture step and some intermediate chromatographic steps, but development and true...... by industry. The theory of residence time based scale-up is developed and applied. (c) 2007 Elsevier B.V. All rights reserved....

  12. Performance and optimization of a combustion interface for isotope ratio monitoring gas chromatography/mass spectrometry

    Science.gov (United States)

    Merritt, D. A.; Freeman, K. H.; Ricci, M. P.; Studley, S. A.; Hayes, J. M.

    1995-01-01

    Conditions and systems for on-line combustion of effluents from capillary gas chromatographic columns and for removal of water vapor from product streams were tested. Organic carbon in gas chromatographic peaks 15 s wide and containing up to 30 nanomoles of carbon was quantitatively converted to CO2 by tubular combustion reactors, 200 x 0.5 mm, packed with CuO or NiO. No auxiliary source of O2 was required because oxygen was supplied by metal oxides. Spontaneous degradation of CuO limited the life of CuO reactors at T > 850 degrees C. Since NiO does not spontaneously degrade, its use might be favored, but Ni-bound carbon phases form and lead to inaccurate isotopic results at T Water must be removed from the gas stream transmitted to the mass spectrometer or else protonation of CO2 will lead to inaccuracy in isotopic analyses. Although thresholds for this effect vary between mass spectrometers, differential permeation of H2O through Nafion tubing was effective in both cases tested, but the required length of the Nafion membrane was 4 times greater for the more sensitive mass spectrometer.

  13. Bead Injection Extraction Chromatography using High-capacity Lab-on-Valve as a Front End to Inductively Coupled Plasma Mass Spectrometry for Rapid Urine Radiobioassay

    DEFF Research Database (Denmark)

    Qiao, Jixin; Hou, Xiaolin; Roos, Per

    2013-01-01

    A novel bead injection (BI) extraction chromatographic microflow system exploiting high-capacity lab-on-valve (LOV) platform coupled with inductively coupled plasma mass spectrometric detection is developed for rapid and automated determination of plutonium in human urine. A microconduit (1 m......L) incorporated within the LOV processing unit is loaded on-line with a metered amount of disposable extraction chromatographic resin (up to 330 mg of TEVA) through programmable beads transport. Selective capture and purification of plutonium onto the resin beads is then performed by pressure driven flow after...

  14. Amalgam-chromatographic separation of magnesium isotopes

    International Nuclear Information System (INIS)

    Klinskij, G.D.; Levkin, A.V.; Ivanov, S.A.

    1990-01-01

    Separation of magnesium isotopes within Mg(Hg)-MgI 2 system (in dimethylformamide) is conducted under amalgam-chromatographic conditions. Separation maximal degree, that is (1.09), for 24 Mg and 26 Mg and separation coefficient (α = 1.0089±0.006) are determined. Light isotopes are found to concentrate in the amalgam. Technique of thermal conversion of flows within amalgam-dimethylformamide system is suggested on the basis of reversible reaction of Ca-Mg element exchange

  15. Validation for chromatographic and electrophoretic methods

    OpenAIRE

    Ribani, Marcelo; Bottoli, Carla Beatriz Grespan; Collins, Carol H.; Jardim, Isabel Cristina Sales Fontes; Melo, Lúcio Flávio Costa

    2004-01-01

    The validation of an analytical method is fundamental to implementing a quality control system in any analytical laboratory. As the separation techniques, GC, HPLC and CE, are often the principal tools used in such determinations, procedure validation is a necessity. The objective of this review is to describe the main aspects of validation in chromatographic and electrophoretic analysis, showing, in a general way, the similarities and differences between the guidelines established by the dif...

  16. Study and ICH validation of a reverse-phase liquid chromatographic method for the quantification of the intact monoclonal antibody cetuximab

    Directory of Open Access Journals (Sweden)

    Antonio Martínez-Ortega

    2016-04-01

    Full Text Available Cetuximab (CTX is a potent chimeric mouse/human monoclonal antibody (mAb approved worldwide for treatment of metastatic colorectal cancer. Among the various biological and physical analyses performed for full study on this biopharmaceutic, the determination of the concentration preparations throughout manufacturing and subsequent handling in hospital is particularly relevant. In the present work, the study and validation of a method for quantifying intact CTX by reverse-phase high-performance liquid chromatography with diode array detection ((RPHPLC/DAD is presented. With that end, we checked the performance of a chromatographic method for quantifying CTX and conducted a study to validate the method as stability-indicating in accordance with the International Conference on Harmonization guidelines (ICH for biotechnological drugs; therefore, we evaluated linearity, accuracy, precision, detection and quantification limits, robustness and system suitability. The specificity of the method and the robustness of the mAb formulation against external stress factors were estimated by comprehensive chromatographic analysis by subjecting CTX to several informative stress conditions. As demonstrated, the method is rapid, accurate, and reproducible for CTX quantification. It was also successfully used to quantify CTX in a long-term stability study performed under hospital conditions.

  17. Structural Analysis of a Polysaccharide from Chlorella kessleri by Means of Gas Chromatography-Mass Spectrometry of Its Saccharide Alditols

    Czech Academy of Sciences Publication Activity Database

    Řezanka, Tomáš; Sigler, Karel

    2007-01-01

    Roč. 52, č. 3 (2007), s. 246-252 ISSN 0015-5632 Institutional research plan: CEZ:AV0Z50200510 Keywords : gas chromatographic * chlorella kessleri * oligosaccharide Subject RIV: EE - Microbiology, Virology Impact factor: 0.989, year: 2007

  18. Research on the separation properties of empty-column gas chromatography (EC-GC) and conditions for simulated distillation (SIMDIS).

    Science.gov (United States)

    Boczkaj, Grzegorz; Kamiński, Marian

    2013-10-01

    Previous studies have revealed it is possible to separate a high-boiling mixture by gas chromatography in empty fused-silica capillary tubing rather than in columns coated with stationary phase. Chromatographic separation occurs solely on the basis of the different boiling points of the substances separated. The high similarity of such separations to those in classic distillation seems advantageous when gas chromatography is used for simulated distillation. This paper presents results from further research on the separation properties of empty fused silica tubing. The efficiency of this chromatographic system has been examined. The usefulness of such conditions has been studied for simulated distillation, i.e. to determine the boiling-point distribution of complex mixtures, mainly petroleum fractions and products, on the basis of their retention relative to reference substances. The results obtained by use of empty-column gas chromatography (EC-GC) and by use of classical simulated distillation columns have been compared for solutes of different polarity. Studies revealed boiling points determined by EC-GC were more accurate than those obtained by the standard method of simulated distillation.

  19. Development and Validation of a Liquid Chromatographic Method ...

    African Journals Online (AJOL)

    A liquid chromatographic method for the simultaneous determination of six human immunodeficiency virus (HIV) protease inhibitors, indinavir, saquinavir, ritonavir, amprenavir, nelfinavir and lopinavir, was developed and validated. Optimal separation was achieved on a PLRP-S 100 Å, 250 x 4.6 mm I.D. column maintained ...

  20. Sensitive high performance liquid chromatographic method for the ...

    African Journals Online (AJOL)

    A new simple, sensitive, cost-effective and reproducible high performance liquid chromatographic (HPLC) method for the determination of proguanil (PG) and its metabolites, cycloguanil (CG) and 4-chlorophenylbiguanide (4-CPB) in urine and plasma is described. The extraction procedure is a simple three-step process ...

  1. Gas Chromatograph Method Optimization Trade Study for RESOLVE: 20-meter Column v. 8-meter Column

    Science.gov (United States)

    Huz, Kateryna

    2014-01-01

    RESOLVE is the payload on a Class D mission, Resource Prospector, which will prospect for water and other volatile resources at a lunar pole. The RESOLVE payload's primary scientific purpose includes determining the presence of water on the moon in the lunar regolith. In order to detect the water, a gas chromatograph (GC) will be used in conjunction with a mass spectrometer (MS). The goal of the experiment was to compare two GC column lengths and recommend which would be best for RESOLVE's purposes. Throughout the experiment, an Inficon Fusion GC and an Inficon Micro GC 3000 were used. The Fusion had a 20m long column with 0.25mm internal diameter (Id). The Micro GC 3000 had an 8m long column with a 0.32mm Id. By varying the column temperature and column pressure while holding all other parameters constant, the ideal conditions for testing with each column length in their individual instrument configurations were determined. The criteria used for determining the optimal method parameters included (in no particular order) (1) quickest run time, (2) peak sharpness, and (3) peak separation. After testing numerous combinations of temperature and pressure, the parameters for each column length that resulted in the most optimal data given my three criteria were selected. The ideal temperature and pressure for the 20m column were 95 C and 50psig. At this temperature and pressure, the peaks were separated and the retention times were shorter compared to other combinations. The Inficon Micro GC 3000 operated better at lower temperature mainly due to the shorter 8m column. The optimal column temperature and pressure were 70 C and 30psig. The Inficon Micro GC 3000 8m column had worse separation than the Inficon Fusion 20m column, but was able to separate water within a shorter run time. Therefore, the most significant tradeoff between the two column lengths was peak separation of the sample versus run time. After performing several tests, it was concluded that better

  2. Current applications of miniaturized chromatographic and electrophoretic techniques in drug analysis.

    Science.gov (United States)

    Aturki, Zeineb; Rocco, Anna; Rocchi, Silvia; Fanali, Salvatore

    2014-12-01

    In the last decade, miniaturized separation techniques have become greatly popular in pharmaceutical analysis. Miniaturized separation methods are increasingly utilized in all processes of drug discovery as well as quality control of pharmaceutical preparation. The great advantages presented by the analytical miniaturized techniques, including high separation efficiency and resolution, rapid analysis and minimal consumption of reagents and samples, make them an attractive alternative to the conventional chromatographic methods for drug analysis. The purpose of this review is to give a general overview of the applicability of capillary electrophoresis (CE), capillary electrochromatography (CEC) and micro/capillary/nano-liquid chromatography (micro-LC/CLC/nano-LC) for the analysis of pharmaceutical formulations, active pharmaceutical ingredients (API), drug impurity testing, chiral drug separation, determination of drugs and metabolites in biological fluids. The results concerning the use of CEC, micro-LC, CLC, and nano-LC in the period 2009-2013, while for CE, those from 2012 up to the review draft are here summarized and some specific examples are discussed. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Studies on Brucella interferon: Chromatographic behaviour and purification

    International Nuclear Information System (INIS)

    Bousquet-Ucla, C.; Wietzerbin, J.; Falcoff, E.

    1980-01-01

    Interferon was induced by infecting mice with Brucella suis. Serum containing interferon activity was analyzed by chromatography on Concanavalin A-Sepharose and Phenyl-Sepharose CL-4B columns. Antiviral activity was completely retained by the lectin column indicating that all the interferon molecules are glycosylated. The chromatographic behaviour of Brucella interferon on Phenyl-Sepharose CL-4B show that, like other interferons, Brucella interferon displays hydrophobic properties. However, the hydrophobicity of the interferon molecule was masked in the crude preparation and was only detectable when purified Brucella interferon was used for chromatography. The antigenic properties of Brucella interferon provided the means for developing an affinity chromatographic method resulting in about 60.000 fold purification. As in the case of viral interferon, treatment of L cells with Brucella interferon induced specific enhanced in vitro phosphorylation of a 67.000 molecular weight protein after incubation of cell extracts with doublestranded RNA and [γ- 32 p]ATP. (auth.)

  4. Rapid thin-layer chromatographic photodensitometric method for the determination of metoclopramide and clebopride in the presence of some of their metabolic products.

    Science.gov (United States)

    Huizing, G; Beckett, A H; Segura, J

    1979-04-21

    Metoclopramide and its newly developed analogue clebopride, together with some of their metabolic products are quantitated, following extraction from biological tissues and fluids, and subsequent separation on silica gel thin-layer chromatographic plates. Diazotisation, followed by coupling with N-(1-naphthyl)ethylenediammonium dichloride, carried out on the thin-layer plate, is utilised for visualisation. The intensity of the spots is measured by photodensitometric analysis. The effect of variation of various experimental conditions is studied. The method has proven to be satisfactory for the measurement of 20 ng/ml of these compounds in biological material; the results are well within the accepted limits of deviation.

  5. Chromatographic determination of Terbinafine in presence of its Photodegradation products

    International Nuclear Information System (INIS)

    Abdel-Moety, E.M.; Kelani, K.O.; Abou Al-Alamein, A.M.

    2003-01-01

    Two different chromatographic techniques have been developed for the determination of terbinafine hydrochloride in presence of its photodegradation products. The first method depends on coupling the TLC- fractionation, on silicia gel 60F254 utilizing chloroform+methanol+25% aq. ammonia ( 12: 0.1:0.1,by volumes), with the direct scanning at 284nm. The second method describes a liquid chromatographic separation of terbinafine and its photolytic degradates on a reversed-phase column[u-Bondapak-TMC 18 (10um,25cmx4.6mm,i.d.)] using a mobile phase containing methanol+water= 80:20 (v/v) with UV-detection at 284 nm. The proposed methods showed significant stability-indication with good linearity, precision and reproducibility. (author)

  6. Study of gas emission from the internal chambers of cryogenic equipment

    International Nuclear Information System (INIS)

    Matyash, Y.I.; Fel'dman, R.G.; Ivakhnenko, Z.N.; Myasnikov, V.M.

    1986-01-01

    One of the methods of improving the efficiency of cryogenic gas equipment (CGE) is adsorption purification of the working medium. The type and quantity of adsorben can be decided after knowing the qualitative and quantitative nature of gas emissions. Gas emissions were studied by the chromatographic method using a heat-conduction detectory. This method made it possible to determine simultaneously the impurities which differ significantly in terms of physicochemical properties. It was established that carbon dioxide and hydrocarbons are continuously emitted in the gaseous medium of the CGE at a constant rate. For the type of machine which was studied, the rates of gas emission were as follows: carbon dioxide and ethane - 0.2 mg/h; ethylene and methane - 0.1 mg/h; propylene, N-butane, and isobutane - 0.2 mg/h

  7. Northwest Asia - gas market outlook: LNG vs. pipeline gas

    International Nuclear Information System (INIS)

    Keun Wook Paik

    1996-01-01

    The share of natural gas in Northeast Asia's energy mix is quite low despite that the region currently dominates the world LNG trade. In the long term, the region's rapid expansion of gas demand in the coming decades looks very likely, but the LNG dominance in the region's gas market will collapse in parallel with the introduction of a long distance pipeline gas. The most likely timing of pipeline gas introduction in Northeast Asian gas market seems to be during the second half of the next decade. (Author)

  8. On-line gas chromatographic studies of rutherfordium (Element 104), hahnium (Element 105), and homologs

    International Nuclear Information System (INIS)

    Kadkhodayan, B.

    1993-05-01

    Gas-phase isothermal chromatogaphy is a method by which volatile compounds of different chemical elements can be separated according to their volatilities. The technique, coupled with theoretical modeling of the processes occurring in the chromatogaphy column, provides accurate determination of thermodynamic properties (e.g., adsorption enthalpies) for compounds of elements, such as the transactinides, which can only be produced on an atom-at-a-time basis. In addition, the chemical selectivity of the isothermal chromatogaphy technique provides the decontamination from interfering activities necessary for the determination of the nuclear decay properties of isotopes of the transactinide elements. Volatility measurements were performed on chloride species of Rf and its group 4 homologs, Zr and Hf, as well as Ha and its group 5 homologs, Nb and Ta. Adsorption enthalpies were calculated for all species using a Monte Carlo code simulation based on a microscopic model for gas thermochromatography in open columns with laminar flow of the carrier gas. Preliminary results are presented for Zr- and Nb-bromides

  9. [Chromatographic mass spectrometric determination of low-molecular-weight aromatic compounds of microbial origin in the serum from patients with sepsis].

    Science.gov (United States)

    Beloborodova, N V; Arkhipova, A S; Beloborodov, D M; Boĭko, N B; Mel'ko, A I; Olenin, A Iu

    2006-02-01

    The investigation quantitatively determined the content of low-molecular-weight aromatic compounds of microbial origin in the sera of 34 individuals by chromatographic mass spectrometry. An "Agilent Technogies 6890N" gas chromatograph with a 5973 mass selective detector was applied; chromatographic separation of components was effected on an Hp-5MS quartz capillary column. Aromatic small molecules originating from microbes (SMOM) were determined in the sera of 7 patients with sepsis. The diagnosis of sepsis was documented by the presence of the systemic inflammation syndrome and by that of bacteriemia and/or artificial ventilation-associated pneumonia along with the level of procalcitonin of higher than 10 ng/ml. The levels of aromatic SMOM were compared in 10 healthy donors, 8 preoperative cardiosurgical patients, and 9 patients with different abnormalities without sepsis treated in an intensive care unit (ICU). Serum phenylacetic and 3-phenylpropionic acids were found to be prevalent in the healthy donors and postoperative cardiosurgical patients. In ICU patients with different complications without sepsis, more than half the compounds under study were undetectable, the others were found in very low concentrations, which may be accounted for by antibiotic therapy. At the same time, almost the whole spectrum of the test compounds (other than 3-phenylpropionic acid) with the highest concentrations of 3-phenyllactic, p-hydroxyphenylacetic, 3-(p-hydroxyphenyl)lactic and 2-hydroxybutanic acids, was detectable in septic patients receiving a more intensive therapy. The differences were statistically significant (by the Mann-Whitney U-test; p < 0.05). By taking into account the potentially high biological activity of the test compounds, studies are to be continued in this area.

  10. A fully automated fast analysis system for capillary gas chromatography. Part 1. Automation of system control

    NARCIS (Netherlands)

    Snijders, H.M.J.; Rijks, J.P.E.M.; Bombeeck, A.J.; Rijks, J.A.; Sandra, P.; Lee, M.L.

    1992-01-01

    This paper is dealing with the design, the automation and evaluation of a high speed capillary gas chromatographic system. A combination of software and hardware was developed for a new cold trap/reinjection device that allows selective solvent eliminating and on column sample enrichment and an

  11. [Sample preparation methods for chromatographic analysis of organic components in atmospheric particulate matter].

    Science.gov (United States)

    Hao, Liang; Wu, Dapeng; Guan, Yafeng

    2014-09-01

    The determination of organic composition in atmospheric particulate matter (PM) is of great importance in understanding how PM affects human health, environment, climate, and ecosystem. Organic components are also the scientific basis for emission source tracking, PM regulation and risk management. Therefore, the molecular characterization of the organic fraction of PM has become one of the priority research issues in the field of environmental analysis. Due to the extreme complexity of PM samples, chromatographic methods have been the chief selection. The common procedure for the analysis of organic components in PM includes several steps: sample collection on the fiber filters, sample preparation (transform the sample into a form suitable for chromatographic analysis), analysis by chromatographic methods. Among these steps, the sample preparation methods will largely determine the throughput and the data quality. Solvent extraction methods followed by sample pretreatment (e. g. pre-separation, derivatization, pre-concentration) have long been used for PM sample analysis, and thermal desorption methods have also mainly focused on the non-polar organic component analysis in PM. In this paper, the sample preparation methods prior to chromatographic analysis of organic components in PM are reviewed comprehensively, and the corresponding merits and limitations of each method are also briefly discussed.

  12. Mechanical stability of a salt cavern submitted to rapid pressure variations: Application to the underground storage of natural gas, compressed air and hydrogen

    International Nuclear Information System (INIS)

    Djizanne-Djakeun, Hippolyte

    2014-01-01

    Salt caverns used for the underground storage of large volumes of natural gas are in high demand given the ever-increasing energy needs. The storage of renewable energy is also envisaged in these salt caverns for example, storage of compressed air and hydrogen mass storage. In both cases, salt caverns are more solicited than before because they are subject to rapid injection and withdrawal rates. These new operating modes raise new mechanical problems, illustrated in particular by sloughing, and falling of overhanging blocks at cavern wall. Indeed, to the purely mechanical stress related to changes in gas pressure variations, repeated dozens of degrees Celsius of temperature variation are superimposed; causes in particular during withdrawal, additional tensile stresses whom may lead to fractures at cavern wall; whose evolution could be dangerous. The mechanical behavior of rock salt is known: it is elasto-viscoplastic, nonlinear and highly thermo sensitive. The existing rock salt constitutive laws and failures and damages criteria have been used to analyze the behavior of caverns under the effects of these new loading. The study deals with the thermo mechanics of rocks and helps to analyze the effects of these new operations modes on the structural stability of salt caverns. The approach was to firstly design and validate a thermodynamic model of the behavior of gas in the cavern. This model was used to analyze blowout in gas salt cavern. Then, with the thermo mechanical coupling, to analyze the effects of rapid withdrawal, rapid injection and daily cycles on the structural stability of caverns. At the experimental level, we sought the optimal conditions to the occurrence and the development of cracks on a pastille and a block of rock salt. The creep behavior of rock salt specimens in triaxial extension also was analyzed. (author)

  13. Gas chromatography interfaced with atmospheric pressure ionization-quadrupole time-of-flight-mass spectrometry by low-temperature plasma ionization

    DEFF Research Database (Denmark)

    Norgaard, Asger W.; Kofoed-Sorensen, Vivi; Svensmark, Bo

    2013-01-01

    A low temperature plasma (LTP) ionization interface between a gas chromatograph (GC) and an atmospheric pressure inlet mass spectrometer, was constructed. This enabled time-of-flight mass spectrometric detection of GC-eluting compounds. The performance of the setup was evaluated by injection...

  14. High-resolution gas chromatographic analysis of polycyclic aromatic hydrocarbons and aliphatic hydrocarbons

    International Nuclear Information System (INIS)

    Perez, M.; Gonzalez, D.

    1988-01-01

    A study of the analysis by gas chromatography of aromatic polycyclic hydrocarbons and aliphatic hydrocarbons is presented. The separation has been carried out by glass and fused silica capillary column in two different polar stationary phases OV-1 and SE-54. The limitation and the advantages of the procedure are discussed in terms of separation, sensitivity and precision. (Author) 20 refs

  15. Vibrational Spectroscopy of Chromatographic Interfaces

    Energy Technology Data Exchange (ETDEWEB)

    Jeanne E. Pemberton

    2011-03-10

    Chromatographic separations play a central role in DOE-supported fundamental research related to energy, biological systems, the environment, and nuclear science. The overall portfolio of research activities in the Separations and Analysis Program within the DOE Office of Basic Energy Sciences includes support for activities designed to develop a molecular-level understanding of the chemical processes that underlie separations for both large-scale and analytical-scale purposes. The research effort funded by this grant award was a continuation of DOE-supported research to develop vibrational spectroscopic methods to characterize the interfacial details of separations processes at a molecular level.

  16. Determination of 3-chloro-1,2-propanediol in polyamideamine epichlorohydrin resin solution by reaction-based headspace gas chromatography.

    Science.gov (United States)

    Yan, Ning; Wan, Xiao-Fang; Chai, Xin-Sheng; Chen, Run-Quan

    2018-04-01

    We report on a headspace gas chromatographic method for determining the content of 3-chloro-1,2-propanediol in polyamideamine epichlorohydrin resin solution. It was based on quantitatively converting 3-chloro-1,2-propanediol to formaldehyde by periodate oxidation in a closed headspace sample vial at a room temperature for 10 min, and then to methanol by borohydride reduction at 90°C for 40 min followed by the headspace gas chromatographic measurement. The results showed that the present method has an excellent measurement precision (relative standard deviation < 2.60%) and accuracy (recoveries from 96.4-102%) in 3-chloro-1,2-propanediol analysis. The limit of quantitation was 0.031 mg/mL. It is simple and suitable for determining the 3-chloro-1,2-propanediol content in polyamideamine epichlorohydrin resin solution. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Rapid One-Pot Microwave Synthesis of Mixed-Linker Hybrid Zeolitic-Imidazolate Framework Membranes for Tunable Gas Separations.

    Science.gov (United States)

    Hillman, Febrian; Brito, Jordan; Jeong, Hae-Kwon

    2018-02-14

    The relatively slow and complex fabrication processes of polycrystalline metal-organic framework (MOF) membranes often times restrict their way to commercialization, despite their potential for molecular separation applications. Herein, we report a rapid one-pot microwave synthesis of mixed-linker hybrid zeolitic-imidazolate framework (ZIF) membranes consisting of 2-methylimidazolate (ZIF-8 linker) and benzimidazolate (ZIF-7 linker) linkers, termed ZIF-7-8 membranes. The fast-volumetric microwave heating in conjunction with a unique counter diffusion of metal and linker solutions enabled unprecedented rapid synthesis of well-intergrown ZIF-7-8 membranes in ∼90 s, the fastest MOF membrane preparation up to date. Furthermore, we were able to tune the molecular sieving properties of the ZIF-7-8 membranes by varying the benzimidazole-to-2-methylimidazole (bIm-to-mIm) linker ratio in the hybrid frameworks. The tuning of their molecular sieving properties led to the systematic change in the permeance and selectivity of various small gases. The unprecedented rapid synthesis of well-intergrown ZIF-7-8 membranes with tunable molecular sieving properties is an important step forward for the commercial gas separation applications of ZIF membranes.

  18. Gas chromatographic determination of cholesterol from food samples using extraction/saponification method

    International Nuclear Information System (INIS)

    Ali, Z.M.; Soomro, A.S.A.

    2007-01-01

    A simple and fast one-step extraction/saponification with Na/OH/KOH (Ethanolic, Sodium Hydroxide/Potassium Hydroxide was compared and validated for determination of cholesterol from locally available 10 edible oil and egg samples. The importance of the use of edible oils and eggs in routine diet is unquestionable, but presence of cholesterol is considered as a risk factor for coronary heart disease and hypertension. The lowering of cholesterol level in order to reduce the risk is widely accepted. The cholesterol in the edible oil and eggs was determined by gas chromatography, through elution from the column (2x3 mm i.d) packed with 3% OV-I01, on Chromosorb G/'NAW 80-100 mesh size at 250-300C with programmed heating rate of 3 degree C/min. Nitrogen gas flow rate was 40 ml/min. The cholesterol samples were run under the conditions after selective extraction in diethyl ether. The calibration was linear within 50-500 IJg/ml concentration range. The amount of cholesterol detected were from 12.92-18.05 mg/g in edible oil and 117.54-143.42 mg/g in egg samples with RSD 1.3-2.7%. (author)

  19. High-performance liquid chromatographic quantitation of desmosine plus isodesmosine in elastin and whole tissue hydrolysates

    International Nuclear Information System (INIS)

    Soskel, N.T.

    1987-01-01

    Quantitation of desmosine and isodesmosine, the major crosslinks in elastin, has been of interest because of their uniqueness and use as markers of that protein. Accurate measurement of these crosslinks may allow determination of elastin degradation in vivo and elastin content in tissues, obviating lengthy extraction procedures. We have developed a method of quantitating desmosine plus isodesmosine in hydrolysates of tissue and insoluble elastin using high-performance liquid chromatographic separation and absorbance detection that is rapid (21-35 min) and sensitive (accurate linearity from 100 pmol to 5 nmol). This method has been used to quantitate desmosines in elastin from bovine nuchal ligament and lung and in whole aorta from hamsters. The ability to completely separate [ 3 H]lysine from desmosine plus isodesmosine allows the method to be used to study incorporation of lysine into crosslinks in elastin

  20. Serodiagnosis of dengue infection using rapid immuno chromatography test in patients with probable dengue infection

    International Nuclear Information System (INIS)

    Kidwai, A.A.; Jamal, Q.; Mehrunnisa, S.; Farooqi, F.R.

    2010-01-01

    Objective: To determine the frequency of seropositive dengue infection using rapid immuno chromatographic assay in patients with probable dengue infection as per WHO criteria. Method: A cross-sectional observational study was conducted at Abbasi Shaheed Hospital, Karachi from July 2008 to January 2009. Patients presenting with acute febrile illness, rashes, bleeding tendencies, leucopenia and or thrombocytopenia were evaluated according to WHO criteria for probable dengue infection. Acute phase sera were collected after 5 days of the onset of fever as per WHO criteria. Serology was performed using rapid immuno chromatographic (ICT) assay with differential detection of IgM and IgG. A primary dengue infection was defined by a positive IgM band and a negative IgG band whereas secondary infection was defined by a positive IgG band with or without positive IgM band. Result: Among 599 patients who met the WHO criteria for dengue infection, 251(41.9%) were found to be ICT reactive among whom 42 (16.73%) had primary infection. Secondary infection was reported in 209 (83.26%). Acute phase sera of 348 (58.09%) were ICT non reactive. Four patients died because of dengue shock syndrome among which three had secondary infection. Conclusion: Early identification of secondary infection in acute phase sera using rapid ICT is valuable in terms of disease progression and mortality. However in highly suspected cases of dengue infection clinical management should not rely on negative serological results. (author)

  1. Pseudo-absolute quantitative analysis using gas chromatography – Vacuum ultraviolet spectroscopy – A tutorial

    Energy Technology Data Exchange (ETDEWEB)

    Bai, Ling [Department of Chemistry & Biochemistry, The University of Texas at Arlington, Arlington, TX (United States); Smuts, Jonathan; Walsh, Phillip [VUV Analytics, Inc., Cedar Park, TX (United States); Qiu, Changling [Department of Chemistry & Biochemistry, The University of Texas at Arlington, Arlington, TX (United States); McNair, Harold M. [Department of Chemistry, Virginia Tech, Blacksburg, VA (United States); Schug, Kevin A., E-mail: kschug@uta.edu [Department of Chemistry & Biochemistry, The University of Texas at Arlington, Arlington, TX (United States)

    2017-02-08

    The vacuum ultraviolet detector (VUV) is a new non-destructive mass sensitive detector for gas chromatography that continuously and rapidly collects full wavelength range absorption between 120 and 240 nm. In addition to conventional methods of quantification (internal and external standard), gas chromatography - vacuum ultraviolet spectroscopy has the potential for pseudo-absolute quantification of analytes based on pre-recorded cross sections (well-defined absorptivity across the 120–240 nm wavelength range recorded by the detector) without the need for traditional calibration. The pseudo-absolute method was used in this research to experimentally evaluate the sources of sample loss and gain associated with sample introduction into a typical gas chromatograph. Standard samples of benzene and natural gas were used to assess precision and accuracy for the analysis of liquid and gaseous samples, respectively, based on the amount of analyte loaded on-column. Results indicate that injection volume, split ratio, and sampling times for splitless analysis can all contribute to inaccurate, yet precise sample introduction. For instance, an autosampler can very reproducibly inject a designated volume, but there are significant systematic errors (here, a consistently larger volume than that designated) in the actual volume introduced. The pseudo-absolute quantification capability of the vacuum ultraviolet detector provides a new means for carrying out system performance checks and potentially for solving challenging quantitative analytical problems. For practical purposes, an internal standardized approach to normalize systematic errors can be used to perform quantitative analysis with the pseudo-absolute method. - Highlights: • Gas chromatography diagnostics and quantification using VUV detector. • Absorption cross-sections for molecules enable pseudo-absolute quantitation. • Injection diagnostics reveal systematic errors in hardware settings. • Internal

  2. Pseudo-absolute quantitative analysis using gas chromatography – Vacuum ultraviolet spectroscopy – A tutorial

    International Nuclear Information System (INIS)

    Bai, Ling; Smuts, Jonathan; Walsh, Phillip; Qiu, Changling; McNair, Harold M.; Schug, Kevin A.

    2017-01-01

    The vacuum ultraviolet detector (VUV) is a new non-destructive mass sensitive detector for gas chromatography that continuously and rapidly collects full wavelength range absorption between 120 and 240 nm. In addition to conventional methods of quantification (internal and external standard), gas chromatography - vacuum ultraviolet spectroscopy has the potential for pseudo-absolute quantification of analytes based on pre-recorded cross sections (well-defined absorptivity across the 120–240 nm wavelength range recorded by the detector) without the need for traditional calibration. The pseudo-absolute method was used in this research to experimentally evaluate the sources of sample loss and gain associated with sample introduction into a typical gas chromatograph. Standard samples of benzene and natural gas were used to assess precision and accuracy for the analysis of liquid and gaseous samples, respectively, based on the amount of analyte loaded on-column. Results indicate that injection volume, split ratio, and sampling times for splitless analysis can all contribute to inaccurate, yet precise sample introduction. For instance, an autosampler can very reproducibly inject a designated volume, but there are significant systematic errors (here, a consistently larger volume than that designated) in the actual volume introduced. The pseudo-absolute quantification capability of the vacuum ultraviolet detector provides a new means for carrying out system performance checks and potentially for solving challenging quantitative analytical problems. For practical purposes, an internal standardized approach to normalize systematic errors can be used to perform quantitative analysis with the pseudo-absolute method. - Highlights: • Gas chromatography diagnostics and quantification using VUV detector. • Absorption cross-sections for molecules enable pseudo-absolute quantitation. • Injection diagnostics reveal systematic errors in hardware settings. • Internal

  3. Feasibility study of hydrogen determination in blended gas mixture by an indigenously developed hydrogen determinator

    International Nuclear Information System (INIS)

    Gaikwad, Revati; Sonar, V.R.; Pandey, R.K.; Karekar, C.D.; Raul, Seema; Mahanty, B.; Kelkar, A.; Bhatt, R.B.; Behere, P.G.

    2017-01-01

    It is required to determine accurately the percentage composition of hydrogen in the blended gas of N 2 and H 2 prior to deliver to the sintering furnace. A feasibility study has been carried out to determine the percentage composition of hydrogen in the blended gas by using an indigenously developed hydrogen determinator. The instrument uses gas chromatograph-thermal conductivity (GC-TCD) technique to determine hydrogen. The flow of carrier gas was kept at 100 mL min -1 during the analysis. A very close agreement between the determined value and the reported value of hydrogen content in the commercially available N 2 -H 2 mixed cylinder was found by using the indigenous hydrogen determinator. (author)

  4. Similarity analyses of chromatographic herbal fingerprints: a review.

    Science.gov (United States)

    Goodarzi, Mohammad; Russell, Paul J; Vander Heyden, Yvan

    2013-12-04

    Herbal medicines are becoming again more popular in the developed countries because being "natural" and people thus often assume that they are inherently safe. Herbs have also been used worldwide for many centuries in the traditional medicines. The concern of their safety and efficacy has grown since increasing western interest. Herbal materials and their extracts are very complex, often including hundreds of compounds. A thorough understanding of their chemical composition is essential for conducting a safety risk assessment. However, herbal material can show considerable variability. The chemical constituents and their amounts in a herb can be different, due to growing conditions, such as climate and soil, the drying process, the harvest season, etc. Among the analytical methods, chromatographic fingerprinting has been recommended as a potential and reliable methodology for the identification and quality control of herbal medicines. Identification is needed to avoid fraud and adulteration. Currently, analyzing chromatographic herbal fingerprint data sets has become one of the most applied tools in quality assessment of herbal materials. Mostly, the entire chromatographic profiles are used to identify or to evaluate the quality of the herbs investigated. Occasionally only a limited number of compounds are considered. One approach to the safety risk assessment is to determine whether the herbal material is substantially equivalent to that which is either readily consumed in the diet, has a history of application or has earlier been commercialized i.e. to what is considered as reference material. In order to help determining substantial equivalence using fingerprint approaches, a quantitative measurement of similarity is required. In this paper, different (dis)similarity approaches, such as (dis)similarity metrics or exploratory analysis approaches applied on herbal medicinal fingerprints, are discussed and illustrated with several case studies. Copyright © 2013

  5. Chromatographic fingerprint similarity analysis for pollutant source identification

    International Nuclear Information System (INIS)

    Xie, Juan-Ping; Ni, Hong-Gang

    2015-01-01

    In the present study, a similarity analysis method was proposed to evaluate the source-sink relationships among environmental media for polybrominated diphenyl ethers (PBDEs), which were taken as the representative contaminants. Chromatographic fingerprint analysis has been widely used in the fields of natural products chemistry and forensic chemistry, but its application to environmental science has been limited. We established a library of various sources of media containing contaminants (e.g., plastics), recognizing that the establishment of a more comprehensive library allows for a better understanding of the sources of contamination. We then compared an environmental complex mixture (e.g., sediment, soil) with the profiles in the library. These comparisons could be used as the first step in source tracking. The cosine similarities between plastic and soil or sediment ranged from 0.53 to 0.68, suggesting that plastic in electronic waste is an important source of PBDEs in the environment, but it is not the only source. A similarity analysis between soil and sediment indicated that they have a source-sink relationship. Generally, the similarity analysis method can encompass more relevant information of complex mixtures in the environment than a profile-based approach that only focuses on target pollutants. There is an inherent advantage to creating a data matrix containing all peaks and their relative levels after matching the peaks based on retention times and peak areas. This data matrix can be used for source identification via a similarity analysis without quantitative or qualitative analysis of all chemicals in a sample. - Highlights: • Chromatographic fingerprint analysis can be used as the first step in source tracking. • Similarity analysis method can encompass more relevant information of pollution. • The fingerprints strongly depend on the chromatographic conditions. • A more effective and robust method for identifying similarities is required

  6. Large-volume injection in gas chromatographic trace analysis using temperature-programmable (PTV) injectors

    NARCIS (Netherlands)

    Mol, J.G.J.; Janssen, J.G.M.; Cramers, C.A.M.G.; Brinkman, U.A.T.

    1996-01-01

    The use of programmed-temperature vaporising (PTV) injectors for large-volume injection in capillary gas chromatography is briefly reviewed. The principles and optimisation of large-volume PTV injection are discussed. Guidelines are given for selection of the PTV conditions and injection mode for

  7. Continuous determination of volatile products in anaerobic fermenters by on-line capillary gas chromatography

    International Nuclear Information System (INIS)

    Diamantis, V.; Melidis, P.; Aivasidis, A.

    2006-01-01

    Bio-ethanol and biogas produced during the anaerobic conversion of organic compounds has been a subject of great interest since the oil crisis of the 1970s. In ethanol fermentation and anaerobic treatment of wastewaters, end-product (ethanol) and intermediate-products (short-chain fatty acids, SCFA) cause inhibition that results in reduced process efficiency. Control of these constituents is of utmost importance for bioreactor optimization and process stability. Ethanol and SCFA can be detected with precision by capillary gas chromatography usually conducted in off-line measurements. In this work, an on-line monitoring and controlling system was developed and connected to the fermenter via an auto-sampling equipment, which could perform the feeding, filtration and dilution of the sample and final injection into the gas chromatograph through an automation-based programmed procedure. The sample was continuously pumped from the recycle stream of the bioreactor and treated using a microfiltration unit. The concentrate was returned to the reactor while the permeate was quantitatively mixed with an internal standard solution. The system comprised of a gas chromatograph with the flow cell and one-shot sampler and a PC with the appropriate software. The on-line measurement of ethanol and SCFA, directly from the liquid phase of an ethanol fermenter and a high-rate continuous mode anaerobic digester, was accomplished by gas chromatography. Also, this monitoring and controlling system was proved to be effective in the continuous fermentation of alcohol-free beer

  8. The effects of curvature on the flow field in rapidly rotating gas centrifuges

    International Nuclear Information System (INIS)

    Wood, H.G.; Jordan, J.A.

    1984-01-01

    The effects of curvature on the fluid dynamics of rapidly rotating gas centrifuges are studied. A governing system of a linear partial differential equation and boundary conditions is derived based on a linearization of the equations for viscous compressible flow. This system reduces to the Onsager pancake model if the effects of curvature are neglected. Approximations to the solutions of the governing equations with and without curvature terms are obtained via a finite-element method. Two examples are considered: first where the flow is driven by a thermal gradient at the wall of the centrifuge, and then for the flow being driven by the introduction and removal of mass through the ends of the centrifuge. Comparisons of the results obtained show that, especially for the second example, the inclusion of the terms due to curvature in the model can have an appreciable effect on the solution. (author)

  9. Determination of dibutylbutylphosphonate in the presence of tributylphosphate by gas liquid chromatography

    International Nuclear Information System (INIS)

    Johnson, S.J.

    1976-05-01

    A gas chromatographic determination of dibutylbutyl-phosphonate in the presence of tributylphosphate was developed. The separation was done on a 183 cm by 3 mm stainless steel column packed with 10 percent Carbowax 20M--TPA on 80/100 mesh Chromosorb W AW and detected by flame ionization. A nitrogen carrier gas flow of 40 cm 3 /min and an oven temperature of 180 0 C produced optimum resolution and column efficiency. The use of temperature programming reduced retention times and thus analysis time. An internal standard of 10 percent v/v n-tridecane was added to all samples and standards

  10. Assessment of the chromatographic lipophilicity of eight cephalosporins on different stationary phases.

    Science.gov (United States)

    Dąbrowska, Monika; Starek, Małgorzata; Komsta, Łukasz; Szafrański, Przemysław; Stasiewicz-Urban, Anna; Opoka, Włodzimierz

    2017-04-01

    The retention behaviors were investigated for a series of eight cephalosporins in thin-layer chromatography (TLC) using stationary phases of RP-2, RP-8, RP-18, NH 2 , DIOL, and CN chemically bonded silica gel. Additionally, various binary mobile phases (water/methanol and water/acetone) were used in different volume proportions. The retention behavior of the analyzed molecules was defined by R M0 constant. In addition, reversed phase high performance liquid chromatography (RP-HPLC) was performed in lipophilicity studies by using immobilized artificial membrane (IAM) stationary phase. Obtained chromatographic data (R M0 and logk' IAM ) were correlated with the lipophilicity, expressed as values of the log calculated (logP calc ) and experimental (logP exp(shake-flask) ) partition coefficient. Principal component analysis (PCA) was applied in order to obtain an overview of similarity or dissimilarity among the analyzed compounds. Hierarchical cluster analysis (HCA) was performed to compare the separation characteristics of the applied stationary phases. This study was undertaken to identify the best chromatographic system and chromatographic data processing method to enable the prediction of logP values. A comprehensive chromatographic investigation into the retention of the analyzed cephalosporins revealed a similar behavior on RP-18, RP-8 and CN stationary phases. The weak correlations obtained between experimental and certain computed lipophilicity indices revealed that R M0 and PC1/RM are relevant lipophilicity parameters and the RP-8, CN and RP-18 plates are appropriate stationary phases for lipophilicity investigation, whereas computational approaches still cannot fully replace experimentation. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Contingency planning for rapid reduction of greenhouse gas emissions

    Directory of Open Access Journals (Sweden)

    Larsson, Nils K.

    2010-03-01

    Full Text Available The current and predicted levels of greenhouse gas (GHG emissions are, according to the best international scientific estimates, leading the world towards climate change that will have serious consequences for all countries. The problem is aggravated by the tendency of people and institutions not to take action until catastrophic consequences emerge. The history of crises in other sectors show us that reactions are likely to focus on ad-hoc reactions or using plans that are readily available, with negative results. However, the alternative of developing public plans for drastic and rapid reductions is not likely to gain support because of their radical nature. The author therefore proposes that large organizations with direct or indirect control over substantial GHG emissions should prepare private contingency plans for very rapid reductions in emissions, so that more rational and less destructive plans will be available when the appropriate moment comes for last-minute action. Examples of the type of specific plans that may be appropriate are suggested.

    Según las estimaciones científicas internacionales más optimistas, los niveles actuales y previstos de emisiones de gases de efecto invernadero (GEI están llevando al mundo hacia un cambio climático que tendrá graves consecuencias para todos los países. El problema se ve agravado por la tendencia de personas e instituciones a no tomar medidas hasta que no se perciben las catastróficas consecuencias. El historial de crisis ocurridas en otros sectores nos demuestra que las reacciones probablemente se centren en medidas ad hoc o en emplear planes que ya existían, pero sin resultados. Sin embargo, es poco probable que la alternativa al desarrollo de planes públicos para las reducciones drásticas y rápidas consiga el apoyo necesario, debido precisamente a su radicalidad. El autor recomienda por tanto que las grandes organizaciones que tengan control directo o indirecto sobre un

  12. QSAR models for prediction of chromatographic behavior of homologous Fab variants.

    Science.gov (United States)

    Robinson, Julie R; Karkov, Hanne S; Woo, James A; Krogh, Berit O; Cramer, Steven M

    2017-06-01

    While quantitative structure activity relationship (QSAR) models have been employed successfully for the prediction of small model protein chromatographic behavior, there have been few reports to date on the use of this methodology for larger, more complex proteins. Recently our group generated focused libraries of antibody Fab fragment variants with different combinations of surface hydrophobicities and electrostatic potentials, and demonstrated that the unique selectivities of multimodal resins can be exploited to separate these Fab variants. In this work, results from linear salt gradient experiments with these Fabs were employed to develop QSAR models for six chromatographic systems, including multimodal (Capto MMC, Nuvia cPrime, and two novel ligand prototypes), hydrophobic interaction chromatography (HIC; Capto Phenyl), and cation exchange (CEX; CM Sepharose FF) resins. The models utilized newly developed "local descriptors" to quantify changes around point mutations in the Fab libraries as well as novel cluster descriptors recently introduced by our group. Subsequent rounds of feature selection and linearized machine learning algorithms were used to generate robust, well-validated models with high training set correlations (R 2  > 0.70) that were well suited for predicting elution salt concentrations in the various systems. The developed models then were used to predict the retention of a deamidated Fab and isotype variants, with varying success. The results represent the first successful utilization of QSAR for the prediction of chromatographic behavior of complex proteins such as Fab fragments in multimodal chromatographic systems. The framework presented here can be employed to facilitate process development for the purification of biological products from product-related impurities by in silico screening of resin alternatives. Biotechnol. Bioeng. 2017;114: 1231-1240. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  13. Stereospecific high-performance liquid chromatographic assay of sotalol in plasma.

    Science.gov (United States)

    Carr, R A; Foster, R T; Bhanji, N H

    1991-09-01

    A convenient high-performance liquid chromatographic (HPLC) assay was developed for determination of sotalol (STL) enantiomers in plasma. Following addition of the internal standard (IS; racemic atenolol), enantiomers of STL and IS were extracted using ethyl acetate. After evaporation of the organic layer, samples were derivatized with a solution of S-(+)-1-(1-naphthyl)ethyl isocyanate (NEIC). The resulting diastereomers were chromatographed with normal-phase HPLC with chloroform:hexane:methanol [65:33:2 (v/v)] as the mobile phase at a flow rate of 2 ml/min. The fluorescence detection wavelength was set at 220 nm for excitation with no emission filter. The suitability of the assay for pharmacokinetic studies was determined by measuring STL enantiomers in the plasma of a healthy subject after administration of a single 160-mg oral, racemic dose of STL.

  14. Ionic liquid-based single-drop microextraction/gas chromatographic/mass spectrometric determination of benzene, toluene, ethylbenzene and xylene isomers in waters.

    Science.gov (United States)

    Aguilera-Herrador, Eva; Lucena, Rafael; Cárdenas, Soledad; Valcárcel, Miguel

    2008-08-01

    The direct coupling between ionic liquid-based single-drop microextraction and gas chromatography/mass spectrometry is proposed for the rapid and simple determination of benzene, toluene, ethylbenzene and xylenes isomers (BTEX) in water samples. The extraction procedure exploits not only the high affinity of the selected ionic liquid (1-methyl-3-octyl-imidazolium hexaflourophosphate) to these aromatic compounds but also its special properties like viscosity, low vapour pressure and immiscibility with water. All the variables involved in the extraction process have been studied in depth. The developed method allows the determination of these single-ring compounds in water under the reference concentration level fixed by the international legislation. In this case, limits of detection were in the range 20 ng L(-1) (obtained for benzene) and 91 ng L(-1) (for o-xylene). The repeatability of the proposed method, expressed as RSD (n=5), varied between 3.0% (o-xylene) and 5.2% (toluene).

  15. A review on sample preparation and chromatographic determination of acephate and methamidophos in

    Directory of Open Access Journals (Sweden)

    Vijay Kumar

    2015-09-01

    Full Text Available Acephate and its metabolite methamidophos are common organophosphorus insecticide used for crop protection. High uses of acephate and methamidophos have induced health issues and environmental pollution. Their undesired presence in the environment is creating ecotoxicology and may harm human health. It is therefore essential to detect the presence of acephate and methamidophos even in trace level. In this review, we have tried to accommodate successful methods of detection of acephate and methamidophos in the different biological media. Their recovery and residue analysis in different media such as vegetables, human and animal tissues have also included. The most common method for their determination is based on chromatographic separation and identification. Among different chromatographic methods, LC and GC coupled with different detectors have used. But, they both need extensive pretreatment and cleanup procedure, before undergoing chromatographic separation and identification. LC coupled with mass spectrometry (LCMS is sometime able to detect acephate and methamidophos in ppm level.

  16. Column chromatographic method for the separation of neodymium from uranium and other elements using poly(dibenzo-18-crown-6)

    International Nuclear Information System (INIS)

    Lad, Shila N.; Mohite, Baburao S.

    2014-01-01

    A simple and efficient column chromatographic method has been developed for the separation of U (VI), Nd (III) and other metals using poly (dibenzo-18-crown-6) as stationary phase and hippuric acid as a counter ion. The various eluting agents were found efficient eluents for Nd (III). The capacity of crown polymer for Nd (III) was found to be 0.55±0.01mmol/g. The tolerance limits of various cations and anions for Nd (III) were determined. Nd (III) was quantitatively separated from other metal ions in binary as well as multicomponent mixtures. The good separation yields were obtained and had good reproducibility (±2%). The method was simple, rapid and selective. (author)

  17. Parameter selection for peak alignment in chromatographic sample profiling: Objective quality indicators and use of control samples

    NARCIS (Netherlands)

    Peters, S.; van Velzen, E.; Janssen, H.-G.

    2009-01-01

    In chromatographic profiling applications, peak alignment is often essential as most chromatographic systems exhibit small peak shifts over time. When using currently available alignment algorithms, there are several parameters that determine the outcome of the alignment process. Selecting the

  18. [Feasibility investigation of hydrogen instead of helium as carrier gas in the determination of five organophosphorus pesticides by gas chromatography-mass spectrometry].

    Science.gov (United States)

    Liu, Zhenxue; Zhou, Shixue

    2015-01-01

    Helium is almost the only choosable carrier gas used in gas chromatography-mass spectrometry (GC-MS). A mixed standard solution of five organophosphorus pesticides was analyzed by using GC-MS, and hydrogen or helium as carrier gas, so as to study the feasibility of hydrogen instead of helium as carrier gas for the determination of organophosphorus pesticides. Combining a mass spectrum database built by ourselves, the results were deconvolved and identified by Automated Mass Spectral Deconvolution & Identification System (AMDIS32), a software belonging to the workstation of the instrument. Then, the statistical software, IBM SPSS Statistics 19.0 was used for the clustering analysis of the data. The results indicated that when hydrogen was used as carrier gas, the peaks of the pesticides detected were slightly earlier than those when helium used as carrier gas, but the resolutions of the chromatographic peaks were lower, and the fraction good indices (Frac. Good) were lower, too. When hydrogen was used as carrier gas, the signals of the pesticides were unstable, the measuring accuracies of the pesticides were reduced too, and even more, some compounds were undetectable. Therefore, considering the measuring accuracy, the signal stability, and the safety, etc., hydrogen should be cautiously used as carrier gas in the determination of organophosphorus pesticides by GC-MS.

  19. The non-proliferation experiment and gas sampling as an on-site inspection activity: A progress report

    International Nuclear Information System (INIS)

    Carrigan, C.R.

    1994-03-01

    The Non-proliferation Experiment (NPE) is contributing to the development of gas sampling methods and models that may be incorporated into future on-site inspection (OSI) activities. Surface gas sampling and analysis, motivated by nuclear test containment studies, have already demonstrated the tendency for the gaseous products of an underground nuclear test to flow hundreds of meters to the surface over periods ranging from days to months. Even in the presence of a uniform sinusoidal pressure variation, there will be a net flow of cavity gas toward the surface. To test this barometric pumping effect at Rainier Mesa, gas bottles containing sulfur hexaflouride and 3 He were added to the pre-detonation cavity for the 1 kt chemical explosives test. Pre-detonation measurements of the background levels of both gases were obtained at selected sites on top of the mesa. The background levels of both tracers were found to be at or below mass spectrographic/gas chromatographic sensitivity thresholds in the parts-per-trillion range. Post-detonation, gas chromatographic analyses of samples taken during barometric pressure lows from the sampling sites on the mesa indicate the presence of significant levels (300--600 ppt) of sulfur hexaflouride. However, mass spectrographic analyses of gas samples taken to date do not show the presence of 3 He. To explain these observations, several possibilities are being explored through additional sampling/analysis and numerical modeling. For the NPE, the detonation point was approximately 400 m beneath the surface of Rainier Mesa and the event did not produce significant fracturing or subsidence on the surface of the mesa. Thus, the NPE may ultimately represent an extreme, but useful example for the application and tuning of cavity gas detection techniques

  20. Identification of vegetable oil botanical speciation in refined vegetable oil blends using an innovative combination of chromatographic and spectroscopic techniques.

    Science.gov (United States)

    Osorio, Maria Teresa; Haughey, Simon A; Elliott, Christopher T; Koidis, Anastasios

    2015-12-15

    European Regulation 1169/2011 requires producers of foods that contain refined vegetable oils to label the oil types. A novel rapid and staged methodology has been developed for the first time to identify common oil species in oil blends. The qualitative method consists of a combination of a Fourier Transform Infrared (FTIR) spectroscopy to profile the oils and fatty acid chromatographic analysis to confirm the composition of the oils when required. Calibration models and specific classification criteria were developed and all data were fused into a simple decision-making system. The single lab validation of the method demonstrated the very good performance (96% correct classification, 100% specificity, 4% false positive rate). Only a small fraction of the samples needed to be confirmed with the majority of oils identified rapidly using only the spectroscopic procedure. The results demonstrate the huge potential of the methodology for a wide range of oil authenticity work. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. Gas chromatography of organic microcontaminants using atomic emission and mass spectrometric detection combined in one instrument (GC-AED/MS)

    NARCIS (Netherlands)

    Mol, H.G.J.; Hankemeier, T.; Brinkman, U.A.T.

    1999-01-01

    This study describes the coupling of an atomic-emission detector and mass-spectrometric detector to a single gas chromatograph. Splitting of the column effluent enables simultaneous detection by atomic-emission detection (AED) and mass spectrometry (MS) and yields a powerful system for the target

  2. Development of sampling method and chromatographic analysis of volatile organic compounds emitted from human skin.

    Science.gov (United States)

    Grabowska-Polanowska, Beata; Miarka, Przemysław; Skowron, Monika; Sułowicz, Joanna; Wojtyna, Katarzyna; Moskal, Karolina; Śliwka, Ireneusz

    2017-10-01

    The studies on volatile organic compounds emitted from skin are an interest for chemists, biologists and physicians due to their role in development of different scientific areas, including medical diagnostics, forensic medicine and the perfume design. This paper presents a proposal of two sampling methods applied to skin odor collection: the first one uses a bag of cellulose film, the second one, using cellulose sachets filled with active carbon. Volatile organic compounds were adsorbed on carbon sorbent, removed via thermal desorption and analyzed using gas chromatograph with mass spectrometer. The first sampling method allowed identification of more compounds (52) comparing to the second one (30). Quantitative analyses for acetone, butanal, pentanal and hexanal were done. The skin odor sampling method using a bag of cellulose film, allowed the identification of many more compounds when compared with the method using a sachet filled with active carbon.

  3. An enzyme-linked immunosorbent assay and a gold-nanoparticle based immuno chromatographic test for amatoxins using recombinant antibody

    International Nuclear Information System (INIS)

    He, Kuo; Zhao, Ruiping; Wang, Lixia; Feng, Tingting; Wei, Dong; Zhang, Xiuyuan

    2016-01-01

    The authors describe two kinds of rapid assays for the determination of amatoxins in mushrooms. The first is an enzyme-linked immunosorbent assay (ELISA) using horseradish peroxidase. The second is a rapid immuno chromatographic assay that uses colloidal gold as a red label (CG-ICA). Both are based on the use of a well-characterized recombinant single chain variable fragment antibody (named scFv-A4). The half-maximum inhibition concentrations (IC50) of α-amanitin, β-amanitin and γ-amanitin are 78, 85 and 90 ng⋅mL"-"1, and the limits of detection (LODs; for IC15) are 1.9, 2.1 and 2.8 ng⋅mL"-"1. The method was applied to the determination of amanitins in mushrooms, and the LODs for α-amanitin, β-amanitin and γ-amanitin in mushroom samples were found to be 4.9, 6.4 and 8.3 ng⋅mL"-"1. The visual minimum detection limits of the optimized CGIA are 4 and 6 ng⋅mL"-"1 for mushroom samples. The test can be performed within 10 min. The results of the analysis of spiked samples showed that the CG-IA can rapidly and semi-quantitatively quantify amatoxins in mushroom samples on site and at low costs. (author)

  4. Simultaneous extraction and quantitation of several bioactive amines in cheese and chocolate.

    Science.gov (United States)

    Baker, G B; Wong, J T; Coutts, R T; Pasutto, F M

    1987-04-17

    A method is described for simultaneous extraction and quantitation of the amines 2-phenylethylamine, tele-methylhistamine, histamine, tryptamine, m- and p-tyramine, 3-methoxytyramine, 5-hydroxytryptamine, cadaverine, putrescine, spermidine and spermine. This method is based on extractive derivatization of the amines with a perfluoroacylating agent, pentafluorobenzoyl chloride, under basic aqueous conditions. Analysis was done on a gas chromatograph equipped with an electron-capture detector and a capillary column system. The procedure is relatively rapid and provides derivatives with good chromatographic properties. Its application to analysis of the above amines in cheese and chocolate products is described.

  5. Determination of 4-Chloroindole-3-Acetic Acid Methyl Ester in Lathyrus Vicia and Pisum by Gas Chromatography - Mass Spectrometry

    DEFF Research Database (Denmark)

    Engvild, Kjeld Christensen; Egsgaard, Helge; Larsen, Elfinn

    1980-01-01

    4-Chloroindole-3-acetic acid methyl ester was identified unequivocally in Lathyrus latifolius L., Vicia faba L. and Pisum sativum L. by thin layer chromatography, gas chromatography and mass spectrometry. The gas chromatographic system was able to separate underivatized chloroindole-3-acetic acid...... methyl ester isomers. The quantitative determination of 4-chloroindole-3-acetic acid methyl ester in immature seeds of these three species was performed by gas chromatography – mass spectrometry using deuterium labelled 4-chloro-indole-3-acetic acid methyl ester as an internal standard. P. sativum...

  6. Direct determination of acrylamide in food by gas chromatography-high-resolution time-of-flight mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Dunovska, Lenka [Institute of Chemical Technology, Department of Food Chemistry and Analysis, Technicka 3, 166 28 Prague 6 (Czech Republic); Cajka, Tomas [Institute of Chemical Technology, Department of Food Chemistry and Analysis, Technicka 3, 166 28 Prague 6 (Czech Republic); Hajslova, Jana [Institute of Chemical Technology, Department of Food Chemistry and Analysis, Technicka 3, 166 28 Prague 6 (Czech Republic)]. E-mail: jana.hajslova@vscht.cz; Holadova, Katerina [Institute of Chemical Technology, Department of Food Chemistry and Analysis, Technicka 3, 166 28 Prague 6 (Czech Republic)

    2006-09-25

    Simple and rapid gas chromatographic (GC) method employing a high-resolution time-of-flight mass analyzer that enables direct analysis (no derivatization) of acrylamide in various heat-processed foodstuffs has been developed and validated. Co-isolation of acrylamide precursors such as sugars and asparagine, constituting the risk of results overestimation due to additional formation of analyte in hot GC injector, is avoided by the extraction with n-propanol followed by solvent exchange to acetonitrile (MeCN). Introduction of a novel purification strategy, dispersive solid phase extraction, based on addition of primary-secondary amine (PSA) sorbent into deffated extract in MeCN, provides a significant reduction of some abundant matrix co-extracts (mainly free fatty acids). Isotope dilution technique (d{sub 3}-acrylamide as an internal standard) is employed for compensation of potential target analyte losses and/or matrix-inducted chromatographic response enhancement. Limits of quantifications (LOQs) ranged between 15 and 40 {mu}g kg{sup -1} and recoveries were between 97 and 108% depending on the examined food matrix. The repeatability of measurements (expressed as relative standard deviation, R.S.D.) was as low as 1.9% for potato crisps containing acrylamide at a level of 1 mg kg{sup -1}. Slightly higher values (R.S.D. < 4.0%) were achieved for breakfast cereals and crisp bread with approximately 10 times lower content of this processing contaminant. Trueness of results generated by this new method was demonstrated via FAPAS[reg] (Food Analysis Performance Assessment Scheme) interlaboratory proficiency tests.

  7. Liquid chromatographic determination of pioglitazone in pharmaceuticals, serum and urine samples

    International Nuclear Information System (INIS)

    Abro, K.; Memon, N.; Bhanger, M.I.; Mahesar, S.A.; Parveen, S.

    2011-01-01

    A rapid and reliable analytical method based on high-performance liquid chromatography (HPLC) with UV detection (221 nm) has been developed for the determination of the anti-hyper glycemic agent Pioglitazone in pharmaceutical formulations and biological fluids (serum and urine) after clean-up with solid-phase extraction. Chromatographic separation was achieved with a Chromolith Performance RP-18e (10 4.6mm) column using mobile phase composition of acetonitrile: mixed phosphate buffer (pH 2.5; 10mM) (30:70, v/v) with a flow rate of 2.0mL/min. The total run time was 2 min. under optimized conditions. The calibration curve was found to be linear in the range of 1-10 mu g mL/sup -1/ with regression coefficient of 0.9996, and the lower limit of detection 72 ng/20 mu L injection. The method has been validated for the system suitability, linearity, precision and accuracy, limits of detection, specificity, stability and robustness. The %recovery of Pioglitazone in pharmaceutical formulations was found to be 104.7%. The assay has been applied successfully to the pharmaceutical Tablet samples and biological fluids (serum and urine) of healthy volunteers. (author)

  8. Exploring Blueberry Aroma Complexity by Chromatographic and Direct-Injection Spectrometric Techniques

    Science.gov (United States)

    Farneti, Brian; Khomenko, Iuliia; Grisenti, Marcella; Ajelli, Matteo; Betta, Emanuela; Algarra, Alberto Alarcon; Cappellin, Luca; Aprea, Eugenio; Gasperi, Flavia; Biasioli, Franco; Giongo, Lara

    2017-01-01

    , for the most aldehydes, alcohols, terpenoids, and esters that can be used as putative biomarkers to rapidly evaluate the blueberry aroma variations related to ripening and/or senescence as well as to genetic background differences. Moreover, the obtained results demonstrated the complementarity between chromatographic and direct-injection mass spectrometric techniques to study the blueberry aroma. PMID:28491071

  9. Exploring Blueberry Aroma Complexity by Chromatographic and Direct-Injection Spectrometric Techniques

    Directory of Open Access Journals (Sweden)

    Brian Farneti

    2017-04-01

    pull of VOCs, for the most aldehydes, alcohols, terpenoids, and esters that can be used as putative biomarkers to rapidly evaluate the blueberry aroma variations related to ripening and/or senescence as well as to genetic background differences. Moreover, the obtained results demonstrated the complementarity between chromatographic and direct-injection mass spectrometric techniques to study the blueberry aroma.

  10. Optimizing Chromatographic Separation: An Experiment Using an HPLC Simulator

    Science.gov (United States)

    Shalliker, R. A.; Kayillo, S.; Dennis, G. R.

    2008-01-01

    Optimization of a chromatographic separation within the time constraints of a laboratory session is practically impossible. However, by employing a HPLC simulator, experiments can be designed that allow students to develop an appreciation of the complexities involved in optimization procedures. In the present exercise, a HPLC simulator from "JCE…

  11. Bioanalytical method transfer considerations of chromatographic-based assays.

    Science.gov (United States)

    Williard, Clark V

    2016-07-01

    Bioanalysis is an important part of the modern drug development process. The business practice of outsourcing and transferring bioanalytical methods from laboratory to laboratory has increasingly become a crucial strategy for successful and efficient delivery of therapies to the market. This chapter discusses important considerations when transferring various types of chromatographic-based assays in today's pharmaceutical research and development environment.

  12. Development of a commercial Automated Laser Gas Interface (ALGI) for AMS

    Energy Technology Data Exchange (ETDEWEB)

    Daniel, R. [National Electrostatics Corporation, Middleton, WI 53562 (United States); Mores, M., E-mail: nec@pelletron.com [National Electrostatics Corporation, Middleton, WI 53562 (United States); Kitchen, R.; Sundquist, M.; Hauser, T.; Stodola, M. [National Electrostatics Corporation, Middleton, WI 53562 (United States); Tannenbaum, S.; Skipper, P.; Liberman, R. [Dept. of Biological Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139 (United States); Young, G.; Corless, S. [Drug Metabolism and Pharmacokinetics, GlaxoSmithKline Research and Development Ltd., Ware (United Kingdom); Tucker, M. [MGT Systems, Chapel Lane, Eastbridge, Suffolk (United Kingdom)

    2013-01-15

    National Electrostatics Corporation (NEC), Massachusetts Institute of Technology (MIT), and GlaxoSmithKline (GSK) collectively have been developing an interface to introduce CO{sub 2} produced by the laser combustion of liquid chromatograph eluate deposited on a CuO substrate directly into the ion source of an AMS system, thereby bypassing the customary graphitization process. The Automated Laser Gas Interface (ALGI) converts dried liquid samples to CO{sub 2} gas quickly and efficiently, allowing 96 samples to be measured in as little as 16 h. {sup 14}C:{sup 12}C ratios stabilize typically within 2 min of analysis time per sample. Presented is the recent progress of NEC's ALGI, a stand-alone accessory to an NEC gas-enabled multi-cathode source of negative ions by Cs sputtering (MC-SNICS) ion source.

  13. Gas Chromatographic Determination of Methyl Salicylate in Rubbing Alcohol: An Experiment Employing Standard Addition.

    Science.gov (United States)

    Van Atta, Robert E.; Van Atta, R. Lewis

    1980-01-01

    Provides a gas chromatography experiment that exercises the quantitative technique of standard addition to the analysis for a minor component, methyl salicylate, in a commercial product, "wintergreen rubbing alcohol." (CS)

  14. Chromatographic separation and spectro-analytical characterization of a natural African mineral dye

    Directory of Open Access Journals (Sweden)

    G.B. Adebayo

    2007-08-01

    Full Text Available Chromatographic fractionation and spectroscopic characterization of a natural African mineral dye have been carried out. The chromatographic separation of the dyes made use of column and thin layer chromatographic techniques. Some physicochemical properties of the dye including solubility in polar and non-polar solvents, pH, ash and organic contents were determined. The spectro-analytical techniques used for characterization included energy dispersive X-ray fluorescence (EDXRF, X-ray diffractometry (XRD, Optical microscopy, infrared (IR and UV-VIS spectroscopy. Four different fractions having colours yellow, grey, orange and purple were obtained from the chromatographic separation. All the fractions were found to contain aromatic nucleus based on IR and UV-VIS spectroscopic data. Other functional groups detected are Ar-NH2, -CONH2, C=C, C-C and metal-carbon chelate rings. The presence of aromatic amine in the dye provides strong evidence for its use as hair dye. The dye was found to be soluble in both aqueous and non-aqueous solvents. The pH of the dye's aqueous solution was found to be 8.6, and the ash and organic content of the raw dye were 49 % and 51 % respectively. The XRF revealed that the dye contains twenty elements with concentrations ranging from major to ultra-trace levels. The XRD also showed that the sample contains about forty-six mineral phases which include both inorganic and organic components. The maximum absorption wavelength (λmax in UV-VIS of the aqueous solution was found to be 464 nm. The optical microscopic investigation gave indication that the dyes are likely to be of the marine origin.

  15. Liquid chromatographic determination of sennosides in Cassia angustifolia leaves.

    Science.gov (United States)

    Srivastava, Alpuna; Pandey, Richa; Verma, Ram K; Gupta, Madan M

    2006-01-01

    A simple liquid chromatographic method was developed for the determination of sennosides B and A in leaves of Cassia angustifolia. These compounds were extracted from leaves with a mixture of methanol-water (70 + 30, v/v) after defatting with hexane. Analyte separation and quantitation were achieved by gradient reversed-phase liquid chromatography and UV absorbance at 270 nm using a photodiode array detector. The method involves the use of an RP-18 Lichrocart reversed-phase column (5 microm, 125 x 4.0 mm id) and a binary gradient mobile-phase profile. The various other aspects of analysis, namely, peak purity, similarity, recovery, repeatability, and robustness, were validated. Average recoveries of 98.5 and 98.6%, with a coefficient of variation of 0.8 and 0.3%, were obtained by spiking sample solution with 3 different concentration solutions of standards (60, 100, and 200 microg/mL). Detection limits were 10 microg/mL for sennoside B and 35 microg/mL for sennoside A, present in the sample solution. The quantitation limits were 28 and 100 microg/mL. The analytical method was applied to a large number of senna leaf samples. The new method provides a reliable tool for rapid screening of C. angustifolia samples in large numbers, which is needed in breeding/genetic engineering and genetic mapping experiments.

  16. Gas chromatograph study of bitumen from oil shale of Amman Formation (upper cretaceous), NW Jordan

    International Nuclear Information System (INIS)

    Darwish, H.; Mustafa, H.

    1997-01-01

    The extractable organic matter of seven outcrop samples of Amman Formation Oil Shale have been analysed by Gas Chromatography (GC). The bitumen is rich in heterocompounds contents (> 60 wt%). Gas chromatograms show a predominance of iosprenoids, specially phytane over n-alkanes, and low carbon preference index (CPI). This indicates that the organic matter is immature, and its origin is mainly of marine organisms. These rocks could be possible source rocks due to the high content of hydrocarbon. (authors). 22 refs., 4 figs. 3 tabs

  17. Gas chromatographic analysis of reactive carbonyl compounds formed from lipids upon UV-irradiation

    International Nuclear Information System (INIS)

    Dennis, K.J.; Shibamoto, T.

    1990-01-01

    Peroxidation of lipids produces carbonyl compounds; some of these, e.g., malonaldehyde and 4-hydroxynonenal, are genotoxic because of their reactivity with biological nucleophiles. Analysis of the reactive carbonyl compounds is often difficult. The methylhydrazine method developed for malonaldehyde analysis was applied to simultaneously measure the products formed from linoleic acid, linolenic acid, arachidonic acid, and squalene upon ultraviolet-irradiation (UV-irradiation). The photoreaction products, saturated monocarbonyl, alpha,beta-unsaturated carbonyls, and beta-dicarbonyls, were derivatized with methylhydrazine to give hydrazones, pyrazolines, and pyrazoles, respectively. The derivatives were analyzed by gas chromatography and gas chromatography-mass spectrometry. Lipid peroxidation products identified included formaldehyde, acetaldehyde, acrolein, malonaldehyde, n-hexanal, and 4-hydroxy-2-nonenal. Malonaldehyde levels formed upon 4 hr of irradiation were 0.06 micrograms/mg from squalene, 2.4 micrograms/mg from linolenic acid, and 5.7 micrograms/mg from arachidonic acid. Significant levels of acrolein (2.5 micrograms/mg) and 4-hydroxy-2-nonenal (0.17 micrograms/mg) were also produced from arachidonic acid upon 4 hr irradiation

  18. Rapid charging of nickel-cadmium accumulators

    Energy Technology Data Exchange (ETDEWEB)

    Bruck, F

    1972-01-01

    Four types of charging of gas-tight Ni-Cd accumulators (a) normal; (b) accelerated; (c) rapid; and (d) ultra-rapid are described. For rapid charging, a built-in temperature sensor cuts off charging current at a prescribed point. In ultra-rapid charging, 50% charge can be attained in 3.5 min. and 25% charge within 50 sec. In the second phase of ultra-rapid charging, a surplus of oxygen is released at the positive electrode and a safety valve is provided for pressure reduction. Characteristic curves are given for various rates of charging and some data on discharge rates is also given.

  19. Online gas analysis and diagnosis for RPC detectors in the ATLAS experiment

    International Nuclear Information System (INIS)

    De Asmundis, Riccardo

    2007-01-01

    Resistive Plate Counters (RPC) detectors need a very strict control of gas parameters: motivations for this statement come from both the request of stability in the detector working point, and chemical consideration concerning potentially aggressive materials generated during the ionization processes into the sensitive gap; the latter point can be relevant because of a possible damage to the internal surface of the detector that has to be avoided in order to ensure an high detection efficiency of the RPC during their ten years or more of operation in ATLAS. In order to understand these aspects, detailed studies on gas behavior have been carried on at the GIF-X5 at CERN (2002-2005), based on Gas Chromatographic and spectroscopy techniques. Main results of these analysis are presented here, together with the design of the online analyzer to be installed on ATLAS conceived to keep control of gas quality and to trigger maintenance interventions on the gas system, in particular on the purification subsystem

  20. Application tests of a new-type LNG rapid gasification unit

    Directory of Open Access Journals (Sweden)

    Ping Yan

    2017-01-01

    Full Text Available Liquefied natural gas (LNG is stored under low temperature and high pressure. It has to be gasified before it is used. Therefore, LNG gasification unit is essential and it is vital to the high-efficiency utilization of LNG. In this paper, a new-type LNG rapid gasification unit was developed. Adopted in this unit are some innovative technologies authorized with the national patent of invention, such as the umbrella-shape gas flow circle unit, the flue gas circulation system and the water feeding system, which help to guarantee its operation safety and increase its operation efficiency. After it was justified in lab test, the unit for industrial application was designed and manufactured and then tested to verify its design rationality. The results show that the new-type LNG rapid gasification unit meets the design requirements in the aspect of efficiency, exhaust gas loss, radiation loss and fuel gas consumption rate; at a load of 1800–2200 m3/h, its efficiency is over 95%; at a load of 1976.0 m3/h which is close to the design value of 2000 m3/h, its efficiency is 96.34% or even up to 2800 m3/h. This new-type LNG rapid gasification unit is adaptable to a large range of loads and can adapt to the rapid increase of external load. Its fuel gas consumption rate is only 1.5%, which is in the range of energy conservation. It presents the advantages of high heating efficiency, rapid startup, high gasification rate, compact structure, small land occupation and invulnerability to the environment, therefore, it is applicable to the middle and small independent regions which cannot be connected to the natural gas supply pipeline networks due to various reasons.

  1. Rapid measurement of plasma free fatty acid concentration and isotopic enrichment using LC/MS

    Science.gov (United States)

    Persson, Xuan-Mai T.; Błachnio-Zabielska, Agnieszka Urszula; Jensen, Michael D.

    2010-01-01

    Measurements of plasma free fatty acids (FFA) concentration and isotopic enrichment are commonly used to evaluate FFA metabolism. Until now, gas chromatography-combustion-isotope ratio mass spectrometry (GC/C/IRMS) was the best method to measure isotopic enrichment in the methyl derivatives of 13C-labeled fatty acids. Although IRMS is excellent for analyzing enrichment, it requires time-consuming derivatization steps and is not optimal for measuring FFA concentrations. We developed a new, rapid, and reliable method for simultaneous quantification of 13C-labeled fatty acids in plasma using high-performance liquid chromatography-mass spectrometry (HPLC/MS). This method involves a very quick Dole extraction procedure and direct injection of the samples on the HPLC system. After chromatographic separation, the samples are directed to the mass spectrometer for electrospray ionization (ESI) and analysis in the negative mode using single ion monitoring. By employing equipment with two columns connected parallel to a mass spectrometer, we can double the throughput to the mass spectrometer, reducing the analysis time per sample to 5 min. Palmitate flux measured using this approach agreed well with the GC/C/IRMS method. This HPLC/MS method provides accurate and precise measures of FFA concentration and enrichment. PMID:20526002

  2. Smart multi-channel two-dimensional micro-gas chromatography for rapid workplace hazardous volatile organic compounds measurement.

    Science.gov (United States)

    Liu, Jing; Seo, Jung Hwan; Li, Yubo; Chen, Di; Kurabayashi, Katsuo; Fan, Xudong

    2013-03-07

    We developed a novel smart multi-channel two-dimensional (2-D) micro-gas chromatography (μGC) architecture that shows promise to significantly improve 2-D μGC performance. In the smart μGC design, a non-destructive on-column gas detector and a flow routing system are installed between the first dimensional separation column and multiple second dimensional separation columns. The effluent from the first dimensional column is monitored in real-time and decision is then made to route the effluent to one of the second dimensional columns for further separation. As compared to the conventional 2-D μGC, the greatest benefit of the smart multi-channel 2-D μGC architecture is the enhanced separation capability of the second dimensional column and hence the overall 2-D GC performance. All the second dimensional columns are independent of each other, and their coating, length, flow rate and temperature can be customized for best separation results. In particular, there is no more constraint on the upper limit of the second dimensional column length and separation time in our architecture. Such flexibility is critical when long second dimensional separation is needed for optimal gas analysis. In addition, the smart μGC is advantageous in terms of elimination of the power intensive thermal modulator, higher peak amplitude enhancement, simplified 2-D chromatogram re-construction and potential scalability to higher dimensional separation. In this paper, we first constructed a complete smart 1 × 2 channel 2-D μGC system, along with an algorithm for automated control/operation of the system. We then characterized and optimized this μGC system, and finally employed it in two important applications that highlight its uniqueness and advantages, i.e., analysis of 31 workplace hazardous volatile organic compounds, and rapid detection and identification of target gas analytes from interference background.

  3. Rapid chromatographic determination of caseins in milk with photometric and fluorimetric detection using a hydrophobic monolithic column.

    Science.gov (United States)

    Ramírez-Palomino, P; Fernández-Romero, J M; Gómez-Hens, A

    2014-01-01

    Reverse-phase liquid chromatographic methods using a hydrophobic C18 monolithic column and on-line photometric and fluorimetric detection for the determination of the major casein (CN) proteins in milk are presented. The separation of αs1-CN, αs2-CN, β-CN and κ-CN was achieved in only five minutes. Fluorimetric detection enabled better analytical results than photometric detection. Thus, the dynamic ranges of the calibration graphs and detection limits obtained using fluorimetric detection were (mgmL(-)(1)): αs1-CN (0.74-10.0, 0.22), αs2-CN (0.15-10.0, 0.045), β-CN (0.68-10.0, 0.20) and κ-CN (0.21-10.0, 0.06). The analytical features of the photometric method, which does not allow the quantification of β-casein, were (mgmL(-)(1)): αs1-CN (1.5-9.0, 0.45), αs2-CN (1.4-10.0, 0.43) and κ-CN (0.4-9.0, 0.12). Precision data, expressed as relative standard deviation, ranged between 0.6% and 5.3% for the fluorimetric method and between 2.4% and 6.2% for the photometric method. Both methods were applied to the analysis of three different milk samples, obtaining recoveries in the ranges of 86.6-103.2% and 92.0-106.5% using fluorimetric and photometric detection, respectively. Copyright © 2013 Elsevier Ltd. All rights reserved.

  4. Use of laminar chromatographic methods for determination of separation conditions in column extraction chromatography

    International Nuclear Information System (INIS)

    Ghersini, G.; Cerrai, E.

    1978-01-01

    Possibilities of using laminar chromatographic methods (paper and thin-layer chromatography) to determine optimal separation conditions in column extraction chromatography are analysed. Most of the given laminar methods are presented as Rf-spectra, i.e. as dependences of Rf found experimentally on eluating solution component concentration. Interrelation between Rf and distribution coefficients of corresponding liquid extraction systems and retention volumes of chromatographic columns is considered. Literature data on extraction paper and thin-layer chromatography of elements with various immovable phases are presented

  5. Dioxin analysis by gas chromatography-Fourier transform ion cyclotron resonance mass spectrometry (GC-FTICRMS).

    Science.gov (United States)

    Taguchi, Vince Y; Nieckarz, Robert J; Clement, Ray E; Krolik, Stefan; Williams, Robert

    2010-11-01

    The feasibility of utilizing a gas chromatograph-tandem quadrupole-Fourier transform ion cyclotron resonance mass spectrometer (GC-MS/MS-FTICRMS) to analyze chlorinated-dioxins/furans (CDDs/CDFs) and mixed halogenated dioxins/furans (HDDs/HDFs) was investigated by operating the system in the GC-FTICRMS mode. CDDs/CDFs and mixed HDDs/HDFs could be analyzed at 50,000 to 100,000 resolving power (RP) on the capillary gas chromatographic time scale. Initial experiments demonstrated that 1 pg of 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD) and 5 pg of 2-bromo-3,7,8-trichlorodibenzo-p-dioxin (BTrCDD) could be detected. The feasibility of utilizing an FTICRMS for screening of CDDs/CDFs, HDDs/HDFs and related compounds was also investigated by analyzing an extract from vegetation exposed to fall-out from an industrial fire. CDDs/CDFs, chlorinated pyrenes and chlorinated tetracenes could be detected from a Kendrick plot analysis of the ultrahigh resolution mass spectra. Mass accuracies were of the order of 0.5 ppm on standards with external mass calibration and 1 ppm on a sample with internal mass calibration. Copyright © 2010 American Society for Mass Spectrometry. Published by Elsevier Inc. All rights reserved.

  6. Enhanced binding by dextran-grafting to Protein A affinity chromatographic media.

    Science.gov (United States)

    Zhao, Lan; Zhu, Kai; Huang, Yongdong; Li, Qiang; Li, Xiunan; Zhang, Rongyue; Su, Zhiguo; Wang, Qibao; Ma, Guanghui

    2017-04-01

    Dextran-grafted Protein A affinity chromatographic medium was prepared by grafting dextran to agarose-based matrix, followed by epoxy-activation and Protein A coupling site-directed to sulfhydryl groups of cysteine molecules. An enhancement of both the binding performance and the stability was achieved for this dextran-grafted Protein A chromatographic medium. Its dynamic binding capacity was 61 mg immunoglobulin G/mL suction-dried gel, increased by 24% compared with that of the non-grafted medium. The binding capacity of dextran-grafted medium decreased about 7% after 40 cleaning-in-place cycles, much lower than that of the non-grafted medium as decreased about 15%. Confocal laser scanning microscopy results showed that immunoglobulin G was bound to both the outside and the inside of dextran-grafted medium faster than that of non-grafted one. Atomic force microscopy showed that this dextran-grafted Protein A medium had much rougher surface with a vertical coordinate range of ±80 nm, while that of non-grafted one was ±10 nm. Grafted dextran provided a more stereo surface morphology and immunoglobulin G molecules were more easily to be bound. This high-performance dextran-grafted Protein A affinity chromatographic medium has promising applications in large-scale antibody purification. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. HDT mixtures treatment strategies by gas chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Laquerbe, C.; Contreras, S.; Demoment, J. [Commissariat a l' Energie Atomique - CEA/Valduc, F-21121 Is sur Tille (France)

    2008-07-15

    Gas phase chromatographic processes are of interest for the separation of hydrogen isotopes from an HDT mixture. For a certain quantity, they are very competitive and present several benefits. Nevertheless no active packing material allows to have simultaneously good enrichment performances for tritium production and high decontamination capabilities for HD gases. The influence of the packing material is first described in this article. Then two specific processes (TCAP and Reverse Chromatography), each well adapted to perform one target, are presented. Finally, the problematic to propose an optimized treatment scheme associating these two processes is formulated. (authors)

  8. HDT mixtures treatment strategies by gas chromatography

    International Nuclear Information System (INIS)

    Laquerbe, C.; Contreras, S.; Demoment, J.

    2008-01-01

    Gas phase chromatographic processes are of interest for the separation of hydrogen isotopes from an HDT mixture. For a certain quantity, they are very competitive and present several benefits. Nevertheless no active packing material allows to have simultaneously good enrichment performances for tritium production and high decontamination capabilities for HD gases. The influence of the packing material is first described in this article. Then two specific processes (TCAP and Reverse Chromatography), each well adapted to perform one target, are presented. Finally, the problematic to propose an optimized treatment scheme associating these two processes is formulated. (authors)

  9. Similarity analyses of chromatographic herbal fingerprints: A review

    International Nuclear Information System (INIS)

    Goodarzi, Mohammad; Russell, Paul J.; Vander Heyden, Yvan

    2013-01-01

    Graphical abstract: -- Highlights: •Similarity analyses of herbal fingerprints are reviewed. •Different (dis)similarity approaches are discussed. •(Dis)similarity-metrics and exploratory-analysis approaches are illustrated. •Correlation and distance-based measures are overviewed. •Similarity analyses illustrated by several case studies. -- Abstract: Herbal medicines are becoming again more popular in the developed countries because being “natural” and people thus often assume that they are inherently safe. Herbs have also been used worldwide for many centuries in the traditional medicines. The concern of their safety and efficacy has grown since increasing western interest. Herbal materials and their extracts are very complex, often including hundreds of compounds. A thorough understanding of their chemical composition is essential for conducting a safety risk assessment. However, herbal material can show considerable variability. The chemical constituents and their amounts in a herb can be different, due to growing conditions, such as climate and soil, the drying process, the harvest season, etc. Among the analytical methods, chromatographic fingerprinting has been recommended as a potential and reliable methodology for the identification and quality control of herbal medicines. Identification is needed to avoid fraud and adulteration. Currently, analyzing chromatographic herbal fingerprint data sets has become one of the most applied tools in quality assessment of herbal materials. Mostly, the entire chromatographic profiles are used to identify or to evaluate the quality of the herbs investigated. Occasionally only a limited number of compounds are considered. One approach to the safety risk assessment is to determine whether the herbal material is substantially equivalent to that which is either readily consumed in the diet, has a history of application or has earlier been commercialized i.e. to what is considered as reference material. In order

  10. Similarity analyses of chromatographic herbal fingerprints: A review

    Energy Technology Data Exchange (ETDEWEB)

    Goodarzi, Mohammad [Department of Analytical Chemistry and Pharmaceutical Technology, Center for Pharmaceutical Research, Vrije Universiteit Brussel, Laarbeeklaan 103, B-1090 Brussels (Belgium); Russell, Paul J. [Safety and Environmental Assurance Centre, Unilever, Colworth Science Park, Sharnbrook, Bedfordshire MK44 1LQ (United Kingdom); Vander Heyden, Yvan, E-mail: yvanvdh@vub.ac.be [Department of Analytical Chemistry and Pharmaceutical Technology, Center for Pharmaceutical Research, Vrije Universiteit Brussel, Laarbeeklaan 103, B-1090 Brussels (Belgium)

    2013-12-04

    Graphical abstract: -- Highlights: •Similarity analyses of herbal fingerprints are reviewed. •Different (dis)similarity approaches are discussed. •(Dis)similarity-metrics and exploratory-analysis approaches are illustrated. •Correlation and distance-based measures are overviewed. •Similarity analyses illustrated by several case studies. -- Abstract: Herbal medicines are becoming again more popular in the developed countries because being “natural” and people thus often assume that they are inherently safe. Herbs have also been used worldwide for many centuries in the traditional medicines. The concern of their safety and efficacy has grown since increasing western interest. Herbal materials and their extracts are very complex, often including hundreds of compounds. A thorough understanding of their chemical composition is essential for conducting a safety risk assessment. However, herbal material can show considerable variability. The chemical constituents and their amounts in a herb can be different, due to growing conditions, such as climate and soil, the drying process, the harvest season, etc. Among the analytical methods, chromatographic fingerprinting has been recommended as a potential and reliable methodology for the identification and quality control of herbal medicines. Identification is needed to avoid fraud and adulteration. Currently, analyzing chromatographic herbal fingerprint data sets has become one of the most applied tools in quality assessment of herbal materials. Mostly, the entire chromatographic profiles are used to identify or to evaluate the quality of the herbs investigated. Occasionally only a limited number of compounds are considered. One approach to the safety risk assessment is to determine whether the herbal material is substantially equivalent to that which is either readily consumed in the diet, has a history of application or has earlier been commercialized i.e. to what is considered as reference material. In order

  11. Chromatographic fingerprinting: An innovative approach for food 'identitation' and food authentication - A tutorial.

    Science.gov (United States)

    Cuadros-Rodríguez, Luis; Ruiz-Samblás, Cristina; Valverde-Som, Lucia; Pérez-Castaño, Estefanía; González-Casado, Antonio

    2016-02-25

    Fingerprinting methods describe a variety of analytical methods that provide analytical signals related to the composition of foodstuffs in a non-selective way such as by collecting a spectrum or a chromatogram. Mathematical processing of the information in such fingerprints may allow the characterisation and/or authentication of foodstuffs. In this context, the particular meaning of 'fingerprinting', in conjunction with 'profiling', is different from the original meanings used in metabolomics. This fact has produced some confusion with the use of these terms in analytical papers. Researchers coming from the metabolomic field could use 'profiling' or 'fingerprinting' on a different way to researchers who are devoted to food science. The arrival of an eclectic discipline, named 'foodomics' has not been enough to allay this terminological problem, since the authors keep on using the terms with both meanings. Thus, a first goal of this tutorial is to clarify the difference between both terms. In addition, the chemical approaches for food authentication, i.e., chemical markers, component profiling and instrumental fingerprinting, have been described. A new term, designated as 'food identitation', has been introduced in order to complete the life cycle of the chemical-based food authentication process. Chromatographic fingerprinting has been explained in detail and some strategies which could be applied has been clarified and discussed. Particularly, the strategies for chromatographic signals acquisition and chromatographic data handling are unified in a single framework. Finally, an overview about the applications of chromatographic (GC and LC) fingerprints in food authentication using different chemometric techniques has been included. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Evaluation of selectivity in homologous multimodal chromatographic systems using in silico designed antibody fragment libraries.

    Science.gov (United States)

    Karkov, Hanne Sophie; Woo, James; Krogh, Berit Olsen; Ahmadian, Haleh; Cramer, Steven M

    2015-12-24

    This study describes the in silico design, surface property analyses, production and chromatographic evaluations of a diverse set of antibody Fab fragment variants. Based on previous findings, we hypothesized that the complementarity-determining regions (CDRs) constitute important binding sites for multimodal chromatographic ligands. Given that antibodies are highly diversified molecules and in particular the CDRs, we set out to examine the generality of this result. For this purpose, four different Fab fragments with different CDRs and/or framework regions of the variable domains were identified and related variants were designed in silico. The four Fab variant libraries were subsequently generated by site-directed mutagenesis and produced by recombinant expression and affinity purification to enable examination of their chromatographic retention behavior. The effects of geometric re-arrangement of the functional moieties on the multimodal resin ligands were also investigated with respect to Fab variant retention profiles by comparing two commercially available multimodal cation-exchange ligands, Capto MMC and Nuvia cPrime, and two novel multimodal ligand prototypes. Interestingly, the chromatographic data demonstrated distinct selectivity trends between the four Fab variant libraries. For three of the Fab libraries, the CDR regions appeared as major binding sites for all multimodal ligands. In contrast, the fourth Fab library displayed a distinctly different chromatographic behavior, where Nuvia cPrime and related multimodal ligand prototypes provided markedly improved selectivity over Capto MMC. Clearly, the results illustrate that the discriminating power of multimodal ligands differs between different Fab fragments. The results are promising indications that multimodal chromatography using the appropriate multimodal ligands can be employed in downstream bioprocessing for challenging selective separation of product related variants. Copyright © 2015 Elsevier B

  13. Mass spectrometric-based stable isotopic 2-aminobenzoic acid glycan mapping for rapid glycan screening of biotherapeutics.

    Science.gov (United States)

    Prien, Justin M; Prater, Bradley D; Qin, Qiang; Cockrill, Steven L

    2010-02-15

    Fast, sensitive, robust methods for "high-level" glycan screening are necessary during various stages of a biotherapeutic product's lifecycle, including clone selection, process changes, and quality control for lot release testing. Traditional glycan screening involves chromatographic or electrophoretic separation-based methods, and, although reproducible, these methods can be time-consuming. Even ultrahigh-performance chromatographic and microfluidic integrated LC/MS systems, which work on the tens of minute time scale, become lengthy when hundreds of samples are to be analyzed. Comparatively, a direct infusion mass spectrometry (MS)-based glycan screening method acquires data on a millisecond time scale, exhibits exquisite sensitivity and reproducibility, and is amenable to automated peak annotation. In addition, characterization of glycan species via sequential mass spectrometry can be performed simultaneously. Here, we demonstrate a quantitative high-throughput MS-based mapping approach using stable isotope 2-aminobenzoic acid (2-AA) for rapid "high-level" glycan screening.

  14. SIMAC - A phosphoproteomic strategy for the rapid separation of mono-phosphorylated from multiply phosphorylated peptides

    DEFF Research Database (Denmark)

    Thingholm, Tine E; Jensen, Ole N; Robinson, Phillip J

    2008-01-01

    spectrometric analysis, such as immobilized metal affinity chromatography or titanium dioxide the coverage of the phosphoproteome of a given sample is limited. Here we report a simple and rapid strategy - SIMAC - for sequential separation of mono-phosphorylated peptides and multiply phosphorylated peptides from...... and an optimized titanium dioxide chromatographic method. More than double the total number of identified phosphorylation sites was obtained with SIMAC, primarily from a three-fold increase in recovery of multiply phosphorylated peptides....

  15. Rapid formation of gas giants, ice giants and super-Earths

    Energy Technology Data Exchange (ETDEWEB)

    Boss, A P [DTM, Carnegie Institution of Washington, 5241 Broad Branch Road, NW, Washington, DC 20015 (United States)], E-mail: boss@dtm.ciw.edu

    2008-08-15

    Giant planets might have been formed by either of the two basic mechanisms, top-down (disk instability) or bottom-up (core accretion). The latter mechanism is the most generally accepted mechanism and it begins with the collisional accumulation of solid cores that may then accrete sufficient gas to become gas giants. The former mechanism is more heretical and begins with the gravitational instability of the protoplanetary disk gas, leading to the formation of self-gravitating protoplanets, within which the dust settles to form a solid core. The disk instability mechanism has been thought of primarily as a mechanism for the formation of gas giants, but if it occurs in a disk that is being photoevaporated by the ultraviolet radiation from nearby massive stars, then the outer gaseous protoplanets can be photoevaporated as well and stripped of their gaseous envelopes. The result would then be ice giants (cold super-Earths), such as the objects discovered recently by microlensing orbiting two presumed M dwarf stars. M dwarfs that form in regions of future high-mass star formation would be expected to produce cold super-Earths orbiting at distances of several astronomical units (AU) and beyond, while M dwarfs that form in regions of low-mass star formation would be expected to have gas giants at those distances. Given that most stars are born in the former rather than in the latter regions, M dwarfs should have significantly more super-Earths than gas giants on orbits of several AU or more.

  16. Rapid formation of gas giants, ice giants and super-Earths

    International Nuclear Information System (INIS)

    Boss, A P

    2008-01-01

    Giant planets might have been formed by either of the two basic mechanisms, top-down (disk instability) or bottom-up (core accretion). The latter mechanism is the most generally accepted mechanism and it begins with the collisional accumulation of solid cores that may then accrete sufficient gas to become gas giants. The former mechanism is more heretical and begins with the gravitational instability of the protoplanetary disk gas, leading to the formation of self-gravitating protoplanets, within which the dust settles to form a solid core. The disk instability mechanism has been thought of primarily as a mechanism for the formation of gas giants, but if it occurs in a disk that is being photoevaporated by the ultraviolet radiation from nearby massive stars, then the outer gaseous protoplanets can be photoevaporated as well and stripped of their gaseous envelopes. The result would then be ice giants (cold super-Earths), such as the objects discovered recently by microlensing orbiting two presumed M dwarf stars. M dwarfs that form in regions of future high-mass star formation would be expected to produce cold super-Earths orbiting at distances of several astronomical units (AU) and beyond, while M dwarfs that form in regions of low-mass star formation would be expected to have gas giants at those distances. Given that most stars are born in the former rather than in the latter regions, M dwarfs should have significantly more super-Earths than gas giants on orbits of several AU or more

  17. π-Extended triptycene-based material for capillary gas chromatographic separations.

    Science.gov (United States)

    Yang, Yinhui; Wang, Qinsi; Qi, Meiling; Huang, Xuebin

    2017-10-02

    Triptycene-based materials feature favorable physicochemical properties and unique molecular recognition ability that offer good potential as stationary phases for capillary gas chromatography (GC). Herein, we report the investigation of utilizing a π-extended triptycene material (denoted as TQPP) for GC separations. As a result, the TQPP capillary column exhibited high column efficiency of 4030 plates m -1 and high-resolution performance for a wide range of analytes, especially structural and positional isomers. Interestingly, the TQPP stationary phase showed unique shape selectivity for alkanes isomers and preferential retention for analytes with halogen atoms and H-bonding nature mainly through their halogen-bonding and H-bonding interactions. In addition, the TQPP column had good repeatability and reproducibility with the RSD values of 0.02-0.34% for run-to-run, 0.09-0.80% for day-to-day and 1.4-5.2% for column-to-column, respectively, and favorable thermal stability up to 280 °C. This work demonstrates the promising future of triptycene-based materials as a new class of stationary phases for GC separations. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Use of a hand-portable gas chromatograph-toroidal ion trap mass spectrometer for self-chemical ionization identification of degradation products related to O-ethyl S-(2-diisopropylaminoethyl) methyl phosphonothiolate (VX)

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Philip A., E-mail: Smith.Philip.A@dol.gov [Uniformed Services University of the Health Sciences, Department of Preventive Medicine and Biometrics, 4301 Jones Bridge Road, Bethesda, MD, 20814 (United States); Lepage, Carmela R. Jackson [Defence R and D Canada - Suffield, Box 400, Station Main, Medicine Hat, Alberta, T1A 8K6 (Canada); Savage, Paul B. [Brigham Young University, Department of Chemistry and Biochemistry, Provo, UT, 84602 (United States); Bowerbank, Christopher R.; Lee, Edgar D. [Torion Technologies Inc., 796 East Utah Valley Drive, Suite 200, American Fork, UT, 84003 (United States); Lukacs, Michael J. [Defence R and D Canada - Suffield, Box 400, Station Main, Medicine Hat, Alberta, T1A 8K6 (Canada)

    2011-04-01

    The chemical warfare agent O-ethyl S-(2-diisopropylaminoethyl) methyl phosphonothiolate (VX) and many related degradation products produce poorly diagnostic electron ionization (EI) mass spectra by transmission quadrupole mass spectrometry. Thus, chemical ionization (CI) is often used for these analytes. In this work, pseudomolecular ([M+H]{sup +}) ion formation from self-chemical ionization (self-CI) was examined for four VX degradation products containing the diisopropylamine functional group. A person-portable toroidal ion trap mass spectrometer with a gas chromatographic inlet was used with EI, and both fixed-duration and feedback-controlled ionization time. With feedback-controlled ionization, ion cooling (reaction) times and ion formation target values were varied. Evidence for protonation of analytes was observed under all conditions, except for the largest analyte, bis(diisopropylaminoethyl)disulfide which yielded [M+H]{sup +} ions only with increased fixed ionization or ion cooling times. Analysis of triethylamine-d{sub 15} provided evidence that [M+H]{sup +} production was likely due to self-CI. Analysis of a degraded VX sample where lengthened ion storage and feedback-controlled ionization time were used resulted in detection of [M+H]{sup +} ions for VX and several relevant degradation products. Dimer ions were also observed for two phosphonate compounds detected in this sample.

  19. Use of a hand-portable gas chromatograph-toroidal ion trap mass spectrometer for self-chemical ionization identification of degradation products related to O-ethyl S-(2-diisopropylaminoethyl) methyl phosphonothiolate (VX)

    International Nuclear Information System (INIS)

    Smith, Philip A.; Lepage, Carmela R. Jackson; Savage, Paul B.; Bowerbank, Christopher R.; Lee, Edgar D.; Lukacs, Michael J.

    2011-01-01

    The chemical warfare agent O-ethyl S-(2-diisopropylaminoethyl) methyl phosphonothiolate (VX) and many related degradation products produce poorly diagnostic electron ionization (EI) mass spectra by transmission quadrupole mass spectrometry. Thus, chemical ionization (CI) is often used for these analytes. In this work, pseudomolecular ([M+H] + ) ion formation from self-chemical ionization (self-CI) was examined for four VX degradation products containing the diisopropylamine functional group. A person-portable toroidal ion trap mass spectrometer with a gas chromatographic inlet was used with EI, and both fixed-duration and feedback-controlled ionization time. With feedback-controlled ionization, ion cooling (reaction) times and ion formation target values were varied. Evidence for protonation of analytes was observed under all conditions, except for the largest analyte, bis(diisopropylaminoethyl)disulfide which yielded [M+H] + ions only with increased fixed ionization or ion cooling times. Analysis of triethylamine-d 15 provided evidence that [M+H] + production was likely due to self-CI. Analysis of a degraded VX sample where lengthened ion storage and feedback-controlled ionization time were used resulted in detection of [M+H] + ions for VX and several relevant degradation products. Dimer ions were also observed for two phosphonate compounds detected in this sample.

  20. Coffee contains cholinomimetic compound distinct from caffeine. I: Purification and chromatographic analysis.

    Science.gov (United States)

    Tse, S Y

    1991-07-01

    Both regular and decaffeinated coffees were found to have cholinomimetic actions when tested in urethane-anesthetized rats. These actions were distinct from those of caffeine and reversible by atropine. The bioactive fraction was purified from alcoholic extracts of instant decaffeinated coffee by liquid column chromatography and preparative TLC. The purified compound showed similar pharmacological actions as the starting material. Chromatographic behavior was further characterized by analytical TLC and HPLC. Chromatographic analyses of extracts of green coffee beans and roasted ground coffees showed that the cardioactive compound was only present in roasted coffees. Similar analyses of other commonly consumed beverages, including teas and cocoa, showed that this compound was not present in beverages besides coffee.