WorldWideScience

Sample records for rapid electron cyclotron

  1. ELECTRON CYCLOTRON WAVES

    NARCIS (Netherlands)

    Westerhof, E.

    2010-01-01

    This lecture gives an overview of heating and current drive with electron cyclotron waves. We present the main theoretical aspects of wave propagation, wave absorption, and non-inductive current drive, as well as important technical aspects for the application of high power electron cyclotron waves,

  2. Electron cyclotron waves

    NARCIS (Netherlands)

    Westerhof, E.

    2012-01-01

    This lecture gives an overview of heating and current drive with electron cyclotron waves. We present the main theoretical aspects of wave propagation, wave absorption, and non-inductive current drive, as well as important technical aspects for the application of high power electron cyclotron waves,

  3. Electron cyclotron waves

    NARCIS (Netherlands)

    Westerhof, E.

    2008-01-01

    This lecture gives an overview of heating and current drive with electron cyclotron waves. We present the main theoretical aspects of wave propagation, wave absorption, and non-inductive current drive, as well as important technical aspects for the application of high power electron cyclotron waves,

  4. EC-5 fifth international workshop on electron cyclotron emission and electron cyclotron heating

    Energy Technology Data Exchange (ETDEWEB)

    Prater, R.; Lohr, J. [eds.

    1985-12-31

    This report contains papers on the following topics: electron cyclotron emission measurements; electron cyclotron emission theory; electron cyclotron heating; gyrotron development; and ECH systems and waveguide development. These paper have been indexed separately elsewhere. (LSP).

  5. Electron cyclotron resonance heating on TEXTOR

    NARCIS (Netherlands)

    Westerhof, E.; Hoekzema, J. A.; Hogeweij, G. M. D.; Jaspers, R. J. E.; Schüller, F. C.; Barth, C. J.; Bongers, W. A.; Donne, A. J. H.; Dumortier, P.; van der Grift, A. F.; van Gorkom, J. C.; Kalupin, D.; Koslowski, H. R.; Kramer-Flecken, A.; Kruijt, O. G.; Cardozo, N. J. L.; Mantica, P.; van der Meiden, H. J.; Merkulov, A.; Messiaen, A.; Oosterbeek, J. W.; Oyevaar, T.; Poelman, A. J.; Polman, R. W.; Prins, P. R.; Scholten, J.; Sterk, A. B.; Tito, C. J.; Udintsev, V.S.; Unterberg, B.; Vervier, M.; van Wassenhove, G.

    2003-01-01

    The 110 GHz and the new 140 GHz gyrotron systems for electron cyclotron resonance heating (ECRH) and ECCD on TEXTOR are described and results of ECRH experiments with the 110 GHz system are reported. Central ECRH on Ohmic plasmas shows the presence of an internal electron transport barrier near q =

  6. Microwave power coupling with electron cyclotron resonance ...

    Indian Academy of Sciences (India)

    Electron cyclotron resonance (ECR) plasma was produced at 2.45 GHz using 200 – 750 W microwave power. The plasma was produced from argon gas at a pressure of 2 × 10−4 mbar. Three water-cooled solenoid coils were used to satisfy the ECR resonant conditions inside the plasma chamber. The basic parameters of ...

  7. Electron-cyclotron-resonance ion sources (review)

    Energy Technology Data Exchange (ETDEWEB)

    Golovanivskii, K.S.; Dougar-Jabon, V.D. [People`s Friendship Univ., Moscow (Russian Federation)

    1992-01-01

    The physical principles are described and a brief survey of the present state is given of ion sources based on electron-cyclotron heating of plasma in a mirror trap. The characteristics of ECR sources of positive and negative ions used chiefly in accelerator technology are presented. 20 refs., 10 figs., 3 tabs.

  8. Tokamak startup with electron cyclotron heating

    Energy Technology Data Exchange (ETDEWEB)

    Holly, D J; Prager, S C; Shepard, D A; Sprott, J C

    1980-04-01

    Experiments are described in which the startup voltage in a tokamak is reduced by approx. 60% by the use of a modest amount of electron cyclotron resonance heating power for preionization. A 50% reduction in volt-second requirement and impurity reflux are also observed.

  9. A line-of-sight electron cyclotron emission receiver for electron cyclotron resonance heating feedback control of tearing modes

    DEFF Research Database (Denmark)

    Oosterbeek, J.W.; Bürger, A.; Westerhof, E.

    2008-01-01

    An electron cyclotron emission (ECE) receiver inside the electron cyclotron resonance heating (ECRH) transmission line has been brought into operation. The ECE is extracted by placing a quartz plate acting as a Fabry-Perot interferometer under an angle inside the electron cyclotron wave (ECW) beam...

  10. Operation of a quasioptical electron cyclotron maser

    Energy Technology Data Exchange (ETDEWEB)

    Morse, E.C.; Pyle, R.V.

    1984-12-01

    The electron cyclotron maser or gyrotron concept has been developed to produce sources producing 200 kW at 28 GHz continuously, and higher power outputs and frequencies in pulsed mode. These sources have been useful in electron cyclotron resonance heating (ECRH) in magnetically confined fusion devices. However, higher frequencies and higher power levels will be required in reactor-grade fusion plasmas, with likely requirements of 1.0 MW or more per source at 140 GHz. Conventional gyrotrons follow a trend of decreasing power for increasing frequency. In order to circumvent this problem, the quasioptical electron cyclotron maser was proposed. In this device, the closed resonator of the conventional gyrotron is replaced with an open, Fabry-Perot type resonator. The cavity modes are then the TEM-type modes of an optical laser. The advantage of this configuration is that the cavity size is not a function of frequency, since the length can be any half-integer number of wavelengths. Furthermore, the beam traverses across the cavity transverse to the direction of radiation output, and thus the rf window design is less complicated than in conventional tubes. The rf output, if obtained by diffraction coupling around one of the mirrors, could be in a TEM mode, which would allow for quasioptical transmission of the microwaves into the plasma in fusion devices. 4 references, 1 figure.

  11. Electron cyclotron emission diagnostics on KSTAR tokamak.

    Science.gov (United States)

    Jeong, S H; Lee, K D; Kogi, Y; Kawahata, K; Nagayama, Y; Mase, A; Kwon, M

    2010-10-01

    A new electron cyclotron emission (ECE) diagnostics system was installed for the Second Korea Superconducting Tokamak Advanced Research (KSTAR) campaign. The new ECE system consists of an ECE collecting optics system, an overmode circular corrugated waveguide system, and 48 channel heterodyne radiometer with the frequency range of 110-162 GHz. During the 2 T operation of the KSTAR tokamak, the electron temperatures as well as its radial profiles at the high field side were measured and sawtooth phenomena were also observed. We also discuss the effect of a window on in situ calibration.

  12. Benchmarking of codes for electron cyclotron heating and electron cyclotron current drive under ITER conditions

    NARCIS (Netherlands)

    Prater, R.; Farina, D.; Gribov, Y.; Harvey, R. W.; Ram, A. K.; Lin-Liu, Y. R.; Poli, E.; Smirnov, A. P.; Volpe, F.; Westerhof, E.; Zvonkovo, A.

    2008-01-01

    Optimal design and use of electron cyclotron heating requires that accurate and relatively quick computer codes be available for prediction of wave coupling, propagation, damping and current drive at realistic levels of EC power. To this end, a number of codes have been developed in laboratories

  13. Study and impact of fast electrons diagnosed by electron cyclotron radiation on Tore-Supra tokamak; Etude et influence des electrons rapides diagnostiques par le rayonnement cyclotronique electronique sur le tokamak Tore Supra

    Energy Technology Data Exchange (ETDEWEB)

    Gomez, P

    1999-12-01

    This thesis aims at characterizing the dynamics of fast electrons generated by the Landau absorption of the hybrid wave and studying their effects on electron cyclotron radiation. The different processes involved in the propagation and resonant absorption of the hybrid wave in plasmas are described. A method such as ray-tracing allows the characterization of the dynamics of heating but this method relies on the hypothesis of geometrical optics. Whenever absorption rate is low as it is in Tore-Supra, the hybrid wave undergoes a series of successive reflections on the edge of the plasma before being completely absorbed. These reflections generate an electromagnetic chaos in which geometrical optics hypothesis are no longer valid. A statistical treatment of the Fokker-Planck equation allows the calculation of the mean distribution function of electrons in the plasma submitted to hybrid wave. The electron cyclotron radiation is then deduced and by assuming that plasma behaves like a black body, a theoretical radiative temperature is calculated. The confrontation of this theoretical temperature profile with experimental values allows the validation of this modeling and the estimation of the effects of fast electrons on temperature measurements. (A.C.)

  14. Electron Cyclotron Resonance Heating of a High-Density Plasma

    DEFF Research Database (Denmark)

    Hansen, F. Ramskov

    1986-01-01

    Various schemes for electron cyclotron resonance heating of tokamak plasmas with the ratio of electron plasma frequency to electron cyclotron frequency, "»pe/^ce* larger than 1 on axis, are investigated. In particular, a mode conversion scheme is investigated using ordinary waves at the fundamental...

  15. Electron cyclotron emission imaging diagnostic system for Rijnhuizen Tokamak Project

    NARCIS (Netherlands)

    Deng, B.H.; Hsia, R. P.; Domier, C.W.; Burns, S. R.; Hillyer, T. R.; N C Luhmann Jr.,; Oyevaar, T.; Donne, A. J. H.; R. T. P. Team,

    1999-01-01

    A 16-channel electron cyclotron emission (ECE) imaging diagnostic system has been developed and installed on the Rijnhuizen Tokamak Project for measuring plasma electron cyclotron emission with a temporal resolution of 2 mu s. The high spatial resolution of the system is achieved by utilizing a low

  16. Unstable plasma characteristics in mirror field electron cyclotron ...

    Indian Academy of Sciences (India)

    Electron cyclotron plasma reactor are prone to instabilities in specific input power [3–. 7] region (150–450 watts). ... Electron cyclotron resonance (ECR) plasma technology has become very important for fabrication of very large scale ... left hand polarized (LHP) wave. Shufflbotham and Thomson [4] observed several distinct.

  17. Single-electron detection and spectroscopy via relativistic cyclotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Asner, David M.; Bradley, Rich; De Viveiros Souza Filho, Luiz A.; Doe, Peter J.; Fernandes, Justin L.; Fertl, M.; Finn, Erin C.; Formaggio, Joseph; Furse, Daniel L.; Jones, Anthony M.; Kofron, Jared N.; LaRoque, Benjamin; Leber, Michelle; MCBride, Lisa; Miller, M. L.; Mohanmurthy, Prajwal T.; Monreal, Ben; Oblath, Noah S.; Robertson, R. G. H.; Rosenberg, Leslie; Rybka, Gray; Rysewyk, Devyn M.; Sternberg, Michael G.; Tedeschi, Jonathan R.; Thummler, Thomas; VanDevender, Brent A.; Woods, N. L.

    2015-04-01

    It has been understood since 1897 that accelerating charges should emit electromagnetic radiation. Cyclotron radiation, the particular form of radiation emitted by an electron orbiting in a magnetic field, was first derived in 1904. Despite the simplicity of this concept, and the enormous utility of electron spectroscopy in nuclear and particle physics, single-electron cyclotron radiation has never been observed directly. Here we demonstrate single-electron detection in a novel radiofrequency spectrometer. We observe the cyclotron radiation emitted by individual electrons that are produced with mildly-relativistic energies by a gaseous radioactive source and are magnetically trapped. The relativistic shift in the cyclotron frequency permits a precise electron energy measurement. Precise beta electron spectroscopy from gaseous radiation sources is a key technique in modern efforts to measure the neutrino mass via the tritium decay endpoint, and this work is a proof-of-concept for future neutrino mass experiments using this technique.

  18. Glow plasma trigger for electron cyclotron resonance ion sources.

    Science.gov (United States)

    Vodopianov, A V; Golubev, S V; Izotov, I V; Nikolaev, A G; Oks, E M; Savkin, K P; Yushkov, G Yu

    2010-02-01

    Electron cyclotron resonance ion sources (ECRISs) are particularly useful for nuclear, atomic, and high energy physics, as unique high current generators of multicharged ion beams. Plasmas of gas discharges in an open magnetic trap heated by pulsed (100 micros and longer) high power (100 kW and higher) high-frequency (greater than 37.5 GHz) microwaves of gyrotrons is promising in the field of research in the development of electron cyclotron resonance sources for high charge state ion beams. Reaching high ion charge states requires a decrease in gas pressure in the magnetic trap, but this method leads to increases in time, in which the microwave discharge develops. The gas breakdown and microwave discharge duration becomes greater than or equal to the microwave pulse duration when the pressure is decreased. This makes reaching the critical plasma density initiate an electron cyclotron resonance (ECR) discharge during pulse of microwave gyrotron radiation with gas pressure lower than a certain threshold. In order to reduce losses of microwave power, it is necessary to shorten the time of development of the ECR discharge. For fast triggering of ECR discharge under low pressure in an ECRIS, we initially propose to fill the magnetic trap with the plasmas of auxiliary pulsed discharges in crossed ExB fields. The glow plasma trigger of ECR based on a Penning or magnetron discharge has made it possible not only to fill the trap with plasma with density of 10(12) cm(-3), required for a rapid increase in plasma density and finally for ECR discharge ignition, but also to initially heat the plasma electrons to T(e) approximately = 20 eV.

  19. Correlation electron cyclotron emission diagnostic in TCV

    Science.gov (United States)

    Fontana, M.; Porte, L.; Molina Cabrera, P.

    2017-08-01

    The correlation electron cyclotron emission diagnostic of tokamak à configuration variable has recently been upgraded. It now has the choice of three lines of sight: two horizontal lines placed on the low field side of the vessel, perpendicular to the magnetic field, and a dual-axis steerable antenna. The polarization of the radiation collected by the latter can be rotated using a universal polarizer situated in the transmission line. This line is also shared with a reflectometry system, allowing simultaneous measurements of temperature and density fluctuations in the same plasma volumes. When using this line, it is possible to choose between two dedicated front ends characterized by different local oscillator frequencies, adding flexibility in the choice of the plasma region to be studied. The intermediate frequency section is now equipped with six frequency tunable YIG filters allowing the study of turbulence properties in a wide range of radial positions. When studying fluctuations over the whole video bandwidth, the minimum detectable fluctuation level is δ Te/Te˜0.5 % . The new system has been used to measure electron temperature fluctuations over a large fraction of the plasma profiles in a series of plasmas with triangularity varying from 0.6 to -0.6 but comparable collisionality profiles.

  20. A new way to measure the electron cyclotron frequency

    Science.gov (United States)

    Palmer, F. L.

    1993-03-01

    A method is described for using spin flips to measure the 0 to 1 cyclotron transition frequency of a single electron in a Penning trap. Detection can be accomplished with magnetic bottles of 10 T/m2 or less, thereby greatly reducing the thermal broadening of the cyclotron line. This method complements a recently published technique for measuring the anomaly frequency, making a more precise measurement of the electron anomaly ratio possible.

  1. Electron-cyclotron heating in the Constance 2 mirror experiment

    Energy Technology Data Exchange (ETDEWEB)

    Mauel, Michael E.

    1982-09-01

    Electron cyclotron heating of a highly-ionized plasma in mirror geometry is investigated. The experimental diagnosis of the electron energy distribution and the comparison of the results of this diagnosis with a two dimensional, time-dependent Fokker-Planck simulation are accomplished in four steps. (1) First, the power balance of the heated and unheated Constance 2 plasma is analyzed experimentally. It is concluded that the heated electrons escape the mirror at a rate dominated by a combination of the influx of cool electrons from outside the mirror and the increased loss rate of the ions. (2) The microwave parameters at the resonance zones are then calculated by cold-plasma ray tracing. High N/sub parallel/ waves are launched and for these waves, strong first-pass absorption is predicted. The absorption strength is qualitatively checked in the experiment by surrounding the plasma with non-reflecting liners. (3) A simplified quasilinear theory including the effect of N/sub parallel/ is developed to model the electrons. An analytic expression is derived for the RF-induced pump-out of the magnetically-confined warm electrons. Results of the Fokker-Planck simulations show the development of the electron energy distribution for several plasma conditions and verify the scaling of the analytic expression for RF-induced diffusion into the loss cone. (4) Sample x-ray and endloss data are presented, and the overall comparison between the simulation and experiment is discussed. The x-ray signals indicate that, for greater RF power, the hot electrondensity increases more rapidly than its temperature. The time history of the endloss data, illustrating RF-enhancement, suggests the predicted scaling for warm-electron pump-out. Finally, a comparison between the measured and predicted energy distribution shows that the bulk, warm and hot components of the heated Constance 2 electrons are indeed reproduced by the simulation.

  2. The electron cyclotron absorption diagnostic at the Rijnhuizen tokamak project

    NARCIS (Netherlands)

    van Gelder, J. F. M.; Miedema, H. S.; Donne, A. J. H.; Oomens, A. A. M.; Schüller, F. C.

    1997-01-01

    A new 20-channel electron cyclotron absorption diagnostic has been developed at the Rijnhuizen tokamak project. It is the first time the electron pressure profile in a tokamak plasma can be measured directly with a time resolution of 1 ms. The diagnostic measures simultaneously the emission and

  3. Cyclotron Resonance of Electrons Trapped in a Microwave Cavity

    Science.gov (United States)

    Elmore, W. C.

    1975-01-01

    Describes an experiment in which the free-electron cyclotron resonance of electrons trapped in a microwave cavity by a Penning trap is observed. The experiment constitutes an attractive alternative to one of the Gardner-Purcell variety. (Author/GS)

  4. Study of microwave components for an electron cyclotron resonance ...

    Indian Academy of Sciences (India)

    Keywords. Microwave system; microwave studio software; network analyser; electron cyclotron resonance ion source. ... of ∼13 eV was obtained. This article describes various aspects of the microwave system including design, fabrication, characterization and performance studies of the microwave components.

  5. Electron cyclotron resonance heating in a short cylindrical plasma ...

    Indian Academy of Sciences (India)

    Electron cyclotron resonance (ECR) plasma is produced and studied in a small cylindrical system. Microwave power is delivered by a CW magnetron at 2.45 GHz in TE10 mode and launched radially to have extraordinary (X) wave in plasma. The axial magnetic field required for ECR in the system is such that the first two ...

  6. Wave propagation through an electron cyclotron resonance layer

    NARCIS (Netherlands)

    Westerhof, E.

    1997-01-01

    The propagation of a wave beam through an electron cyclotron resonance layer is analysed in two-dimensional slab geometry in order to assess the deviation from cold plasma propagation due to resonant, warm plasma changes in wave dispersion. For quasi-perpendicular propagation, N-parallel to x

  7. Electron cyclotron resonance breakdown studies in a linear plasma ...

    Indian Academy of Sciences (India)

    Abstract. Electron cyclotron resonance (ECR) plasma breakdown is studied in a small linear cylindrical system with four different gases – hydrogen, helium, argon and nitrogen. Microwave power in the experimental system is delivered by a magnetron at 2.45 ± 0.02. GHz in TE10 mode and launched radially to have ...

  8. Study of microwave components for an electron cyclotron resonance ...

    Indian Academy of Sciences (India)

    rious aspects of the microwave system including design, fabrication, characterization and performance studies of the microwave components. Keywords. Microwave system; microwave studio software; network analyser; electron cyclotron resonance ion source. 1. Introduction. Microwave systems at 2.45 GHz have been ...

  9. Unstable plasma characteristics in mirror field electron cyclotron ...

    Indian Academy of Sciences (India)

    Electron cyclotron plasma reactor are prone to instabilities in specific input power [3–7] region (150–450 watts). In this region power absorption by gas molecules in the cavity is very poor and enhanced input power gets reflected substantially without increasing ion density. There are abrupt changes in plasma characteristics ...

  10. Application of compact electron cyclotron resonance ion source

    NARCIS (Netherlands)

    Muramatsu, M.; Kitagawa, A.; Iwata, Y.; Ogawa, H.; Hojo, S.; Kubo, T.; Kato, Y.; Biri, S.; Fekete, E.; Yoshida, Y.; Drentje, A. G.

    The compact electron cyclotron resonance (ECR) ion source with a permanent magnet configuration (Kei2 source) has been developed at National Institute of Radiological Sciences for a new carbon therapy facility. The Kei2 source was designed for production of C(4+) ions; its performance such as beam

  11. Physics of electron cyclotron current drive on DIII-D

    CERN Document Server

    Petty, C C; Harvey, R W; Kinsey, J E; Lao, L L; Lohr, J; Luce, T C; Makowski, M A; Prater, R

    2002-01-01

    OAK A271 PHYSICS OF ELECTRON CYCLOTRON CURRENT DRIVE ON DIII-D. Recent experiments on the DIII-D tokamak have focused on determining the effect of trapped particles on the electron cyclotron current drive (ECCD) efficiency. The measured ECCD efficiency increases as the deposition location is moved towards the inboard midplane or towards smaller minor radius for both co and counter injection. The measured ECCD efficiency also increases with increasing electron density and/or temperature. The experimental ECCD is compared to both the linear theory (Toray-GA) as well as a quasilinear Fokker-Planck model (CQL3D). The experimental ECCD is found to be in better agreement with the more complete Fokker-Planck calculation, especially for cases of high rf power density and/or loop voltage. The narrow width of the measured ECCD profile is consistent with only low levels of radial transport for the current carrying electrons.

  12. Electron cyclotron emission imaging diagnostic system for Rijnhuizen Tokamak Project

    Energy Technology Data Exchange (ETDEWEB)

    Deng, B.H.; Hsia, R.P.; Domier, C.W.; Burns, S.R.; Hillyer, T.R.; Luhmann, N.C. Jr. [University of California at Davis, 228 Walker Hall, Davis, California 95616 (United States); Oyevaar, T.; Donne, A.J. [FOM-Inst. voor Plasmafysica Rijnhuizen, Association Euratom-FOM (International organizations without location); RTP team

    1999-01-01

    A 16-channel electron cyclotron emission (ECE) imaging diagnostic system has been developed and installed on the Rijnhuizen Tokamak Project for measuring plasma electron cyclotron emission with a temporal resolution of 2 {mu}s. The high spatial resolution of the system is achieved by utilizing a low cost linear mixer/receiver array. Unlike conventional ECE diagnostics, the sample volumes of the ECE imaging system are aligned vertically, and can be shifted across the plasma cross-section by varying the local oscillator frequency, making possible 2D measurements of electron temperature profiles and fluctuations. The poloidal/radial wavenumber spectra and correlation lengths of T{sub e} fluctuations in the plasma core can also be obtained by properly positioning the focal plane of the imaging system. Due to these unique features, ECE imaging is an ideal tool for plasma transport study. Technical details of the system are described, together with preliminary experimental results. {copyright} {ital 1999 American Institute of Physics.}

  13. Electron Cyclotron Waves Polarization in the TJII Stellarator

    Energy Technology Data Exchange (ETDEWEB)

    Cappa, A.; Martinez-Fernandez, J.; Wagner, D.

    2013-05-01

    This report describes the theoretical calculations related with the electron cyclotron (EC) waves polarization control in the TJII stellarator. Two main aspects will be distinguished: the determination of the vacuum polarization that the wave must exhibit if a given propagation mode in a cold plasma is desired and the calculation of the behavior of the grooved polarizers and other transmission systems used to launch the vacuum wave with the required polarization. (Author) 13 refs.

  14. Prospects for advanced electron cyclotron resonance and electron beam ion source charge breeding methods for EURISOL.

    Science.gov (United States)

    Delahaye, P; Galata, A; Angot, J; Ban, G; Celona, L; Choinski, J; Gmaj, P; Jakubowski, A; Jardin, P; Kalvas, T; Koivisto, H; Kolhinen, V; Lamy, T; Lunney, D; Maunoury, L; Porcellato, A M; Prete, G F; Steckiewicz, O; Sortais, P; Thuillier, T; Tarvainen, O; Traykov, E; Varenne, F; Wenander, F

    2012-02-01

    As the most ambitious concept of isotope separation on line (ISOL) facility, EURISOL aims at producing unprecedented intensities of post-accelerated radioactive isotopes. Charge breeding, which transforms the charge state of radioactive beams from 1+ to an n+ charge state prior to post-acceleration, is a key technology which has to overcome the following challenges: high charge states for high energies, efficiency, rapidity and purity. On the roadmap to EURISOL, a dedicated R&D is being undertaken to push forward the frontiers of the present state-of-the-art techniques which use either electron cyclotron resonance or electron beam ion sources. We describe here the guidelines of this R&D.

  15. Summary of EC-17: the 17th Joint Workshop on Electron Cyclotron Emission and Electron Cyclotron Resonance Heating (Deurne, The Netherlands, 7-10 May 2012)

    NARCIS (Netherlands)

    Westerhof, E.; Austin, M. E.; Kubo, S.; Lin-Liu, Y. R.; Plaum, B.

    2013-01-01

    An overview is given of the papers presented at the 17th Joint Workshop on Electron Cyclotron Emission (ECE) and Electron Cyclotron Resonance Heating (ECRH). The meeting covered all aspects of the research field ranging from theory to enabling technologies. From the workshop, advanced control by

  16. Calibration of electron cyclotron emission radiometer for KSTAR.

    Science.gov (United States)

    Kogi, Y; Jeong, S H; Lee, K D; Akaki, K; Mase, A; Kuwahara, D; Yoshinaga, T; Nagayama, Y; Kwon, M; Kawahata, K

    2010-10-01

    We developed and installed an electron cyclotron emission radiometer for taking measurements of Korea Superconducting Tokamak Advanced Research (KSTAR) plasma. In order to precisely measure the absolute value of electron temperatures, a calibration measurement of the whole radiometer system was performed, which confirmed that the radiometer has an acceptably linear output signal for changes in input temperature. It was also found that the output power level predicted by a theoretical calculation agrees with that obtained by the calibration measurement. We also showed that the system displays acceptable noise-temperature performance around 0.23 eV.

  17. Why NASA and the Space Electronics Community Cares About Cyclotrons

    Science.gov (United States)

    LaBel, Kenneth A.

    2017-01-01

    NASA and the space community are faced with the harsh reality of operating electronic systems in the space radiation environment. Systems need to work reliably (as expected for as long as expected) and be available during critical operations such as docking or firing a thruster. This talk will provide a snapshot of the import of ground-based research on the radiation performance of electronics. Discussion topics include: 1) The space radiation environment hazard, 2) Radiation effects on electronics, 3) Simulation of effects with cyclotrons (and other sources), 4) Risk prediction for space missions, and, 5) Real-life examples of both ground-based testing and space-based anomalies and electronics performance. The talk will conclude with a discussion of the current state of radiation facilities in North America for ground-based electronics testing.

  18. Mechanism for electron cyclotron heating of collisionless plasma

    Energy Technology Data Exchange (ETDEWEB)

    Golovanivskii, K.S.; Dugard-Jabon, V.D.; Milant' ev, V.P.

    1975-01-01

    The electron distribution with respect to transverse energy is derived for electron cyclotron resonance in a constant, homogeneous magnetic field; weak relativistic effects are taken into account. After the establishment of a steady-state distribution with groups of hot and cold electrons, no energy is pumped from the rf field to the plasma. The rf electrostatic perturbations are studied on the basis of the distribution function found; it is shown that waves of two types are unstable eigenmodes of the plasma at rest and drift waves. The growth rates for the corresponding instabilities are derived. A study is also made of the stability of right-handed circularly polarized electromagnetic wave propagating along the magnetic field. Instabilities occur at frequencies which depend on the degree of anisotropy, analogous to the case of a plasma with a temperature anisotropy.

  19. Electron cyclotron emission measurements on JET: Michelson interferometer, new absolute calibration, and determination of electron temperature

    NARCIS (Netherlands)

    Schmuck, S.; Fessey, J.; Gerbaud, T.; Alper, B.; Beurskens, M. N. A.; de la Luna, E.; Sirinelli, A.; Zerbini, M.

    2012-01-01

    At the fusion experiment JET, a Michelson interferometer is used to measure the spectrum of the electron cyclotron emission in the spectral range 70-500 GHz. The interferometer is absolutely calibrated using the hot/cold technique and, in consequence, the spatial profile of the plasma electron

  20. The Electron Cyclotron Resonance Light Source Assembly of PTB - ELISA

    CERN Document Server

    Gruebling, P; Ulm, G

    1999-01-01

    In the radiometry laboratory of the Physikalisch-Technische,Bundesanstalt at the Berlin electron storage ring BESSY I, radiation sources for radiometric applications in industry and basic research in the vacuum ultraviolet (VUV) spectral range are developed, characterized and calibrated. Established sources such as deuterium lamps, Penning and hollow cathode discharge sources have limited spectral ranges and in particular their stability and life time suffers from the erosion of the cathode material. To overcome these limitations we have developed a radiation source based on the principle of the electron cyclotron resonance ion source. ELISA is a 10 GHz monomode source with a compact design featuring a tunable cavity and axially positionable permanent magnets. The radiation emission of the source can be detected simultaneously in the VUV and X-ray spectral range via a toroidal grating monochromator and a Si(Li)-detector. The special design of the source allows spectroscopic investigations of the plasma in dep...

  1. One-electron quantum cyclotron (and implications for cold antihydrogen)

    CERN Document Server

    Gabrielse, G; Odom, B; D'Urso, B

    2001-01-01

    Quantum jumps between Fock states of a one-electron oscillator reveal the quantum limit of a cyclotron accelerator. The states live for seconds when spontaneous emission is inhibited by a factor of 140 within a cylindrical Penning trap cavity. Averaged over hours the oscillator is in thermal equilibrium with black-body photons in the cavity. At 80 mK, quantum jumps occur only when resonant microwave photons are introduced into the cavity, opening a route to improved measurements of the magnetic moments of the electron and positron. The temperature demonstrated is about 60 times lower than the 4.2 K temperature at which charged elementary particles were previously stored. Implications for the production of cold antihydrogen are discussed. (21 refs).

  2. Quantum oscillation of the cyclotron mass in two-dimensional electron systems in silicon

    NARCIS (Netherlands)

    Kaesen, K.F.; Huber, A; Lorenz, H.; Kotthaus, J.P.; Bakker, S.; Klapwijk, T.M

    1996-01-01

    The cyclotron resonance of two-dimensional electron systems in silicon metal-oxide-semiconductor devices is investigated for high electron densities in high magnetic fields. The cyclotron mass, extracted from the resonance frequency, shows an oscillatory behavior. The periodicity of this oscillation

  3. Periodic Beam Current Oscillations Driven by Electron Cyclotron Instabilities in ECRIS Plasmas

    OpenAIRE

    Tarvainen, Olli; Kalvas, Taneli; Koivisto, Hannu; Komppula, Jani; Kronholm, Risto; Laulainen, Janne; Izotov, I.; Mansfeld, D.; Skalyga, V.; Toivanen, V.

    2014-01-01

    Experimental observation of cyclotron instabilities in electron cyclotron resonance ion source plasma operated in cwmode is reported. The instabilities are associated with strong microwave emission and a burst of energetic electrons escaping the plasma, and explain the periodic oscillations of the extracted beam currents. The instabilities are shown to restrict the parameter space available for the optimization of high charge state ion currents.

  4. Electron cyclotron emission measurements at the stellarator TJ-K

    Energy Technology Data Exchange (ETDEWEB)

    Sichardt, Gabriel; Ramisch, Mirko [Institut fuer Grenzflaechenverfahrenstechnik und Plasmatechnologie, Universitaet Stuttgart (Germany); Koehn, Alf [Max-Planck-Institut fuer Plasmaphysik, Garching (Germany)

    2016-07-01

    Electron temperature (T{sub e}) measurements in the magnetised plasmas of the stellarator TJ-K are currently performed by means of Langmuir probes. The use of these probes is restricted to relatively low temperatures and the measurement of temperature profiles requires the acquisition of the local current-voltage characteristics which limits strongly the sampling rate. As an alternative, T{sub e} can be measured using the electron cyclotron emission (ECE) that is generated by the gyration of electrons in magnetised plasmas. Magnetic field gradients in the plasma lead to a spatial distribution of emission frequencies and thus the measured intensity at a given frequency can be related to its point of origin. The T{sub e} dependence of the intensity then leads to a temperature profile along the line of sight for Maxwellian velocity distributions. A diagnostic system for T{sub e} measurements using ECE is currently being set up at TJ-K. When non-thermal electrons are present the emission spectrum changes dramatically. Therefore, the ECE can also be used to investigate the contribution of fast electrons to previously observed toroidal net currents in TJ-K. Simulations are used to examine the role of electron drift orbits in generating these currents.

  5. Numerical model of electron cyclotron resonance ion source

    Directory of Open Access Journals (Sweden)

    V. Mironov

    2015-12-01

    Full Text Available Important features of the electron cyclotron resonance ion source (ECRIS operation are accurately reproduced with a numerical code. The code uses the particle-in-cell technique to model the dynamics of ions in ECRIS plasma. It is shown that a gas dynamical ion confinement mechanism is sufficient to provide the ion production rates in ECRIS close to the experimentally observed values. Extracted ion currents are calculated and compared to the experiment for a few sources. Changes in the simulated extracted ion currents are obtained with varying the gas flow into the source chamber and the microwave power. Empirical scaling laws for ECRIS design are studied and the underlying physical effects are discussed.

  6. Alternative optical concept for electron cyclotron emission imaging.

    Science.gov (United States)

    Liu, J X; Milbourne, T; Bitter, M; Delgado-Aparicio, L; Dominguez, A; Efthimion, P C; Hill, K W; Kramer, G J; Kung, C; Kubota, S; Kasparek, W; Lu, J; Pablant, N A; Park, H; Tobias, B

    2014-11-01

    The implementation of advanced electron cyclotron emission imaging (ECEI) systems on tokamak experiments has revolutionized the diagnosis of magnetohydrodynamic (MHD) activities and improved our understanding of instabilities, which lead to disruptions. It is therefore desirable to have an ECEI system on the ITER tokamak. However, the large size of optical components in presently used ECEI systems have, up to now, precluded the implementation of an ECEI system on ITER. This paper describes a new optical ECEI concept that employs a single spherical mirror as the only optical component and exploits the astigmatism of such a mirror to produce an image with one-dimensional spatial resolution on the detector. Since this alternative approach would only require a thin slit as the viewing port to the plasma, it would make the implementation of an ECEI system on ITER feasible. The results obtained from proof-of-principle experiments with a 125 GHz microwave system are presented.

  7. Research of the Electron Cyclotron Emission with Vortex Property excited by high power high frequency Gyrotron

    Science.gov (United States)

    Goto, Yuki; Kubo, Shin; Tsujimura, Tohru; Takubo, Hidenori

    2017-10-01

    Recently, it has been shown that the radiation from a single electron in cyclotron motion has vortex property. Although the cyclotron emission exists universally in nature, the vortex property has not been featured because this property is normally cancelled out due to the randomness in gyro-phase of electrons and the development of detection of the vortex property has not been well motivated. In this research, we are developing a method to generate the vortex radiation from electrons in cyclotron motion with controlled gyro-phase. Electron that rotates around the uniform static magnetic field is accelerated by right-hand circular polarized (RHCP) radiation resonantly when the cyclotron frequency coincides with the applied RHCP radiation frequency. A large number of electrons can be coherently accelerated in gyro-phase by a RHCP high power radiation so that these electrons can radiate coherent emission with vortex feature. We will show that vortex radiation created by purely rotating electrons for the first time.

  8. Electron cyclotron resonance heating in the microwave tokamak experiment

    Energy Technology Data Exchange (ETDEWEB)

    Allen, S.L.; Casper, T.A.; Fenstermacher, M.E. [and others

    1992-09-01

    This paper presents the results from a series of Electron Cyclotron Resonance Heating (ECRH) experiments on the Microwave Tokamak Experiment (MTX). On-axis heating at B{sub T} = 5T (f{sub ce} = 140 GHz) has been performed at electron densities up to cutoff. We have used both a long-pulse gryotron ({approximately}200 kW, {approximately}0.1s) and a pulsed Free Electron Laser (FEL) as microwave sources. Gyrotron experiments with power densities corresponding to 4 MW m{sup {minus}3}. A far infrared (FIR) polarimeter measured peaking of plasma current profiles in some discharges during the ECRH pulse. During high-power single-pulse FEL experiments, single-pass microwave !transmission measurements show nonlinear effects; i.e., higher transmission than predicted by linear theory. A corrugated-wall duct was used in the tokamak port to increase the gradient of the parallel refractive index n{sub parallel} of the incident wave, and increased absorption was observed. Evidence of electron tail heating during FEL pulses was observed on soft x-ray and ECE diagnostics. These results are in agreement with predictions of nonlinear theory; extrapolation of this theory to reactor-like conditions indicates efficient absorption and heating. A Laser Assisted Particle Probe Spectroscopy (LAPPS) diagnostic provided estimates of the vacuum electric field of the FEL which were consistent with the measured power. Multiple pulse operation of the ETA-II accelerator for the FEL has also been demonstrated, indicating the feasibility of high-average power FEL operation.

  9. Electron-cyclotron plasma startup in the GDT experiment

    CERN Document Server

    Yakovlev, D V; Gospodchikov, E D; Solomakhin, A L; Savkin, V Ya; Bagryansky, P A

    2016-01-01

    The paper reports on a new plasma startup scenario in the Gas Dynamic Trap (GDT) magnetic mirror device. The primary 5 MW neutral beam injection (NBI) plasma heating system fires into a sufficiently dense plasma target ("seed plasma"), which is commonly supplied by an arc plasma generator. In the reported experiments, a different approach to seed plasma generation is explored. One of the channels of the electron cyclotron resonance (ECR) heating system is used to ionize the neutral gas and build up the density of plasma to a level suitable for NBI capture. After a short transition (about 1 ms) the discharge becomes essentially similar to a standard one initiated by the plasma gun. The paper presents the discharge scenario and experimental data on the seed plasma evolution during ECR heating, along with the dependencies on incident microwave power, magnetic configuration and pressure of a neutral gas. The characteristics of consequent high-power NBI discharge are studied and differences to the conventional sce...

  10. Simulating Electron Cyclotron Maser Emission for Low Mass Stars

    Science.gov (United States)

    Llama, Joe; Jardine, Moira

    2018-01-01

    Zeeman-Doppler Imaging (ZDI) is a powerful technique that enables us to map the large-scale magnetic fields of stars spanning the pre- and main-sequence. Coupling these magnetic maps with field extrapolation methods allow us to investigate the topology of the closed, X-ray bright corona, and the cooler, open stellar wind.Using ZDI maps of young M dwarfs with simultaneous radio light curves obtained from the VLA, we present the results of modeling the Electron-Cyclotron Maser (ECM) emission from these systems. We determine the X-ray luminosity and ECM emission that is produced using the ZDI maps and our field extrapolation model. We compare these findings with the observed radio light curves of these stars. This allows us to predict the relative phasing and amplitude of the stellar X-ray and radio light curves.This benchmarking of our model using these systems allows us to predict the ECM emission for all stars that have a ZDI map and an observed X-ray luminosity. Our model allows us to understand the origin of transient radio emission observations and is crucial for disentangling stellar and exoplanetary radio signals.

  11. Development of helium electron cyclotron wall conditioning on TCV

    Science.gov (United States)

    Douai, D.; Goodman, T.; Isayama, A.; Fukumoto, M.; Wauters, T.; Sozzi, C.; Coda, S.; Blanchard, P.; Figini, L.; Garavaglia, S.; Miyata, Y.; Moro, A.; Ricci, D.; Silva, M.; Theiler, C.; Vartanian, S.; Verhaegh, K.; the EUROfusion MST1 Team; the TCV Team

    2018-02-01

    JT-60SA envisions electron cyclotron wall conditioning (ECWC), as wall conditioning method in the presence of the toroidal field to control fuel and impurity recycling and to improve plasma performance and reproducibility. This paper reports on Helium ECWC experiments on TCV in support of JT-60SA operation. Nearly sixty Helium conditioning discharges have been successfully produced in TCV, at a toroidal field B T  =  1.3 or 1.54 T, with gyrotrons at 82.7 GHz in X2 mode, mimicking ECWC operation in JT-60SA at the second harmonic of the EC wave. Discharge parameters were tuned in order to (i) minimize the time for the onset of ECWC plasmas, thus minimizing absorption of stray radiation by in-vessel components, (ii) improve discharge homogeneity by extending the discharge vertically and radially, and wall coverage, in particular of inboard surfaces where JT-60SA plasmas will be initiated, (iii) assess the efficiency of He-ECWC to deplete carbon walls from fuel. An optimized combination of vertical and radial magnetic fields, with amplitudes typically 0.1 to 0.6% of that of B T, has been determined, which resulted in lowest breakdown time, improved wall coverage and enhanced fuel removal. A standard ohmic D 2-plasma could be then sustained, whereas it would not have been possible without He-ECWC.

  12. Electron cyclotron wave sources and applications for fusion

    Science.gov (United States)

    Thomassen, K. I.

    1990-03-01

    Advances in magnetic fusion research have come as often from the use of new technologies as from the invention of ideas and discovery of phenomena that are then applied to new experiments. The technologies needed for plasma production, heating, confinement, and control have largely been developed and are a major factor in the success of our current experiments. These include high vacuum techniques, normal and superconducting magnets, particle beams, pellet fueling devices, and rf sources in the ion cylotron and lower hybrid range of frequencies. One area where development is especially required, and where the potential impact on fusion research is large, is that of electron cyclotron wave (ECW) sources in the 100-600 GHz range. This journal issue is devoted to methods for ECW generation and transmission, and to applications including heating, current drive, profile shaping, and instability control. To help focus these articles the requirements(1) for a system to heat the Compact Ignition Tokamak (CIT) were used to define the necessary technology. Somewhat lower frequencies, but similar power, is anticipated(2) for the International Thermonuclear Experimental Reactor (ITER), and for future large devices of that class, should they use ECW sources in them.

  13. Electron cyclotron plasma startup in the GDT experiment

    Science.gov (United States)

    Yakovlev, D. V.; Shalashov, A. G.; Gospodchikov, E. D.; Solomakhin, A. L.; Savkin, V. Ya.; Bagryansky, P. A.

    2017-01-01

    We report on a new plasma startup scenario in the gas dynamic trap (GDT) magnetic mirror device. The primary 5 MW neutral beam injection (NBI) plasma heating system fires into a sufficiently dense plasma target (‘seed plasma’), which is commonly supplied by an arc plasma generator. In the reported experiments, a different approach to seed plasma generation is explored. One of the channels of the electron cyclotron resonance (ECR) heating system is used to ionize the neutral gas and build up the density of plasma to a level suitable for NBI capture. After a short transition of approximately 1 ms the discharge becomes essentially similar to a standard one initiated by the plasma gun. This paper presents the discharge scenario and experimental data on the seed plasma evolution during ECRH, along with the dependencies on incident microwave power, magnetic configuration and pressure of a neutral gas. The characteristics of the consequent high-power NBI discharge are studied and differences from the conventional scenario are discussed. A theoretical model describing the ECR breakdown and the seed plasma accumulation in a large-scale mirror trap is developed on the basis of the GDT experiment.

  14. Influence of electron injection on electron cyclotron resonance plasma properties and reflected mode electrons (abstract)

    Science.gov (United States)

    Ovsyannikov, V. P.; Ullmann, F.; Zschornack, G.

    2000-02-01

    The injection of an additional strong focused electron beam from a special designed electron gun into a magnetic electron cyclotron resonance (ECR) confinement field is studied. The electron gun uses a cathode with a long lifetime and resistiveness providing high emission current densities with electron currents up to 50 mA and voltages up to 4 keV. A sequence of aluminum foils is used to investigate the trajectories of the electrons in the magnetic field without plasma. The high density electron beam passes through the foils, welds them, and prints its image into the foils. Details of this technique are described in Ref. 1. Using this technique we see that before the electrons enter the sextupole region the beam moves along the magnetic straight lines preserving its structure. Only a central beam passes through the sextupole region, thereby changing its form due to the interaction with radial components of the magnetic field. A new operation method at our 14.5 GHz ECR ion source is based on so-called reflection mode electrons (RMEs) analogous to a known electron beam ion source operation regime.2 The basic idea is that electrons, which traveling from the cathode in a strong axial field, meet an anticathode potential, are reflected from it, move back to the cathode, and will be reflected again and so on. It can be supposed that the electrons will make reflections up to the moment when the anode aperture of the gun is fulfilled and the electrons will be collected on the anode electrode. Investigations are performed extracting nitrogen ions using the RME beam. As a result we got a clear increase in the beam current of the extracted ions (e.g., at 10 mA electron injection an increase of the current of N5+ ions up to 400%) and a shift of the measured ion charge state distribution to higher mean ionization stages. Measured x-ray spectra from a neon loaded plasma show for the case of RME operation increasing energy shifts to the high energy side of the spectra, i.e., the

  15. Status of a compact electron cyclotron resonance ion source for National Institute of Radiological Sciences-930 cyclotron.

    Science.gov (United States)

    Hojo, S; Katagiri, K; Nakao, M; Sugiura, A; Muramatsu, M; Noda, A; Okada, T; Takahashi, Y; Komiyama, A; Honma, T; Noda, K

    2014-02-01

    The Kei-source is a compact electron cyclotron resonance ion source using only permanent magnets and a frequency of 10 GHz. It was developed at the National Institute of Radiological Sciences (NIRS) for producing C(4+) ions oriented for high-energy carbon therapy. It has also been used as an ion source for the NIRS-930 cyclotron. Its microwave band region for the traveling-wave-tube amplifier and maximum output power are 8-10 GHz and 350 W, respectively. Since 2006, it has provided various ion beams such as proton, deuteron, carbon, oxygen, and neon with sufficient intensity (200 μA for proton and deuteron, 50 μA for C(4+), for example) and good stability for radioisotope production, tests of radiation damage, and basic research experiments. Its horizontal and vertical emittances were measured using a screen monitor and waist-scan. The present paper reports the current status of the Kei-source.

  16. Status of a compact electron cyclotron resonance ion source for National Institute of Radiological Sciences-930 cyclotron

    Science.gov (United States)

    Hojo, S.; Katagiri, K.; Nakao, M.; Sugiura, A.; Muramatsu, M.; Noda, A.; Okada, T.; Takahashi, Y.; Komiyama, A.; Honma, T.; Noda, K.

    2014-02-01

    The Kei-source is a compact electron cyclotron resonance ion source using only permanent magnets and a frequency of 10 GHz. It was developed at the National Institute of Radiological Sciences (NIRS) for producing C4+ ions oriented for high-energy carbon therapy. It has also been used as an ion source for the NIRS-930 cyclotron. Its microwave band region for the traveling-wave-tube amplifier and maximum output power are 8-10 GHz and 350 W, respectively. Since 2006, it has provided various ion beams such as proton, deuteron, carbon, oxygen, and neon with sufficient intensity (200 μA for proton and deuteron, 50 μA for C4+, for example) and good stability for radioisotope production, tests of radiation damage, and basic research experiments. Its horizontal and vertical emittances were measured using a screen monitor and waist-scan. The present paper reports the current status of the Kei-source.

  17. Latitudinal dependence of nonlinear interaction between electromagnetic ion cyclotron wave and radiation belt relativistic electrons

    Science.gov (United States)

    Su, Zhenpeng; Zhu, Hui; Xiao, Fuliang; Zheng, Huinan; Shen, Chao; Wang, Yuming; Wang, Shui

    2013-06-01

    Electromagnetic ion cyclotron (EMIC) waves are long suggested to account for the rapid loss of radiation belt relativistic electrons. Here we perform both theoretical analysis and numerical simulation to comprehensively investigate the nonlinear interaction between EMIC wave and relativistic electrons. In particular, we emphasize the dependence of nonlinear processes on the electron initial latitude. The nonlinear phase trapping yields negative equatorial pitch angle transport, with efficiency varying over the electron initial latitude, implying that it can increase the loss rate predicted by quasilinear theory. The nonlinear channel effect phase bunching produces positive equatorial pitch angle transport, less dependent on the electron initial latitude, suggesting that it can decrease the loss rate predicted by quasilinear theory. The nonlinear cluster effect phase bunching alternately causes positive and negative equatorial pitch angle transport, quasi-periodically dependent on the electron initial latitude, suggesting that it can either decrease or increase the loss rate predicted by the quasilinear theory. Such latitudinal dependence of nonlinear processes should be taken into account in the evaluation of radiation belt electron loss rate driven by EMIC waves.

  18. Interaction of the electron density fluctuations with electron cyclotron waves from the equatorial launcher in ITER

    Science.gov (United States)

    Snicker, A.; Poli, E.; Maj, O.; Guidi, L.; Köhn, A.; Weber, H.; Conway, G. D.; Henderson, M.; Saibene, G.

    2018-01-01

    We present a numerical investigation of electron cyclotron beams interacting with electron density fluctuations in the ITER 15 MA H-mode scenario. In particular, here we study how the beam from the equatorial launcher, which shall be utilized to influence the sawtooth instability, is affected by the fluctuations. Moreover, we present the theory and first estimates of the power that is scattered from the injected O-mode to a secondary X-mode in the presence of the fluctuations. It is shown that for ITER parameters the scattered power stays within acceptable limits and broadening of the equatorial beams is less than those from the upper launcher.

  19. Three-dimensional simulations of ion dynamics in an Electron Cyclotron Resonance Ion Source

    NARCIS (Netherlands)

    Beijers, J. P. M.; Mironov, V.

    We present a three-dimensional simulation of the ion dynamics in an electron cyclotron resonance ion source. Ion trajectories in the min-B field of the source are calculated taking ion-ion and electron-ion collisions into account. The electrons are not tracked but considered as a neutralizing

  20. Experiments with biased cylinder in electron cyclotron resonance ion source (plenary)

    NARCIS (Netherlands)

    Drentje, AG; Kitagawa, A; Muramatsu, M; Ogawa, H; Sakamoto, Y

    The shape of the magnetic field of an electron cyclotron resonance ion source (ECRIS) gives rise to different particle fluxes (losses) from the plasma to the end plates (mainly diffusion of electrons), and to the side walls (mainly ions). The electron fluxes to the injection end plate can be reduced

  1. First results of electron cyclotron emission measurements at the GDT magnetic mirror

    CERN Document Server

    Shalashov, A G; Gospodchikov, E D; Lubyako, L V; Yakovlev, D V; Bagryansky, P A

    2016-01-01

    This paper summarizes the results of experiments on electron cyclotron emission (ECE) measurements at the fundamental harmonic recently performed at the axially symmetric magnetic mirror device GDT (Budker Institute, Novosibirsk). New ECE diagnostics is installed to facilitate the successful electron cyclotron resonance heating experiment and operates in the vicinity of the heating frequency of 54.5 GHz. Besides expected emission of thermal electrons, a clearly resolved non-thermal ECE is observed indicating the presence of suprathermal electrons driven by high-power microwave heating. The particulars of plasma emission are studied experimentally in a broad range of discharge scenarios.

  2. Electron cyclotron emission at the fundamental harmonic in GDT magnetic mirror

    Science.gov (United States)

    Shalashov, A. G.; Solomakhin, A. L.; Gospodchikov, E. D.; Lubyako, L. V.; Yakovlev, D. V.; Bagryansky, P. A.

    2017-08-01

    New electron cyclotron emission (ECE) diagnostics has been installed to facilitate the successful experiment of electron cyclotron plasma heating (ECRH) in a large open magnetic trap GDT at Budker Institute. The particularities of ECE in the vicinity of the ECRH frequency were studied experimentally for a broad range of discharge scenarios. The measured thermal emission has partly validated the existing physical conceptions about microwave plasma heating in the machine. Besides the expected emission of thermal electrons, a clearly resolved non-thermal ECE was observed which unambiguously confirmed the presence of suprathermal electrons driven by high-power microwave heating.

  3. The 88-Inch Cyclotron: A One-Stop Facility for Electronics Radiation and Detector Testing

    Energy Technology Data Exchange (ETDEWEB)

    Kireeff Covo, M.; Albright, R. A.; Ninemire, B. F.; Johnson, M. B.; Hodgkinson, A.; Loew, T.; Benitez, J. Y.; Todd, D. S.; Xie, D. Z.; Perry, T.; Phair, L.; Bernsteiny, L. A.; Bevins, J.; Brown, J. A.; Goldblum, B. L.; Harasty, M.; Harrig, K. P.; Laplace, T. A.; Matthews, E. F.; Bushmaker, A.; Walker, D.; Oklejas, V.; Hopkins, A. R.; Bleuel, D. L.; Chen, J.; Cronin, S. B.

    2017-10-01

    In outer space down to the altitudes routinely flown by larger aircrafts, radiation can pose serious issues for microelectronics circuits. The 88-Inch Cyclotron at Lawrence Berkeley National Laboratory is a sector-focused cyclotron and home of the Berkeley Accelerator Space Effects Facility, where the effects of energetic particles on sensitive microelectronics are studied with the goal of designing electronic systems for the space community. This paper describes the flexibility of the facility and its capabilities for testing the bombardment of electronics by heavy ions, light ions, and neutrons. Experimental capabilities for the generation of neutron beams from deuteron breakups and radiation testing of carbon nanotube field effect transistor will be discussed.

  4. The influence of the edge density fluctuations on electron cyclotron wave beam propagation in tokamaks

    DEFF Research Database (Denmark)

    Bertelli, N.; Balakin, A.A.; Westerhof, E.

    2010-01-01

    A numerical analysis of the electron cyclotron (EC) wave beam propagation in the presence of edge density fluctuations by means of a quasi-optical code [Balakin A. A. et al, Nucl. Fusion 48 (2008) 065003] is presented. The effects of the density fluctuations on the wave beam propagation are estim......A numerical analysis of the electron cyclotron (EC) wave beam propagation in the presence of edge density fluctuations by means of a quasi-optical code [Balakin A. A. et al, Nucl. Fusion 48 (2008) 065003] is presented. The effects of the density fluctuations on the wave beam propagation...

  5. Status report of the multipurpose superconducting electron cyclotron resonance ion source

    NARCIS (Netherlands)

    Ciavola, G.; Gammino, S.; Barbarino, S.; Celona, L.; Consoli, F.; Gallo, G.; Maimone, F.; Mascali, D.; Passarello, S.; Galata, A.; Tinschert, K.; Spaedtke, P.; Lang, R.; Maeder, J.; Rossbach, J.; Koivisto, H.; Savonen, M.; Koponen, T.; Suominen, P.; Ropponen, T.; Barue, C.; Lechartier, M.; Beijers, J. P. M.; Brandenburg, S.; Kremers, H. R.; Vanrooyen, D.; Kuchler, D.; Scrivens, R.; Schachter, L.; Dobrescu, S.; Stiebing, K.

    Intense heavy ion beam production with electron cyclotron resonance (ECR) ion sources is a common requirement for many of the accelerators under construction in Europe and elsewhere. An average increase of about one order of magnitude per decade in the performance of ECR ion sources was obtained up

  6. Study of the Polarization Strategy for Electron Cyclotron Heating Systems on HL-2M

    Science.gov (United States)

    Zhang, F.; Huang, M.; Xia, D. H.; Song, S. D.; Wang, J. Q.; Huang, B.; Wang, H.

    2016-06-01

    As important components integrated in transmission lines of electron cyclotron heating systems, polarizers are mainly used to obtain the desired polarization for highly efficient coupling between electron cyclotron waves and plasma. The polarization strategy for 105-GHz electron cyclotron heating systems of HL-2M tokamak is studied in this paper. Considering the polarizers need high efficiency, stability, and low loss to realize any polarization states, two sinusoidal-grooved polarizers, which include a linear polarizer and an elliptical polarizer, are designed with the coordinate transformation method. The parameters, the period p and the depth d, of two sinusoidal-grooved polarizers are optimized by a phase difference analysis method to achieve an almost arbitrary polarization. Finally, the optimized polarizers are manufactured and their polarization characteristics are tested with a low-power test platform. The experimental results agree well with the numerical calculations, indicating that the designed polarizers can meet the polarization requirements of the electron cyclotron heating systems of HL-2M tokamak.

  7. Destabilization of fast particle stabilized sawteeth in ASDEX Upgrade with electron cyclotron current drive

    DEFF Research Database (Denmark)

    Igochine, V.; Chapman, I.T.; Bobkov, V.

    2011-01-01

    Upgrade for destabilization of fast particle stabilized sawteeth with electron cyclotron current drive (ECCD). It is shown that moderate ECCD from a single gyrotron is able to destabilize the fast particle stabilized sawteeth. A reduction in sawtooth period by about 40% was achieved in first experiments...

  8. Three-wave interaction during electron cyclotron resonance heating and current drive

    DEFF Research Database (Denmark)

    Nielsen, Stefan Kragh; Jacobsen, Asger Schou; Hansen, Søren Kjer

    2016-01-01

    Non-linear wave-wave interactions in fusion plasmas, such as the parametric decay instability (PDI) of gyrotron radiation, can potentially hamper the use of microwave diagnostics. Here we report on anomalous scattering in the ASDEX Upgrade tokamak during electron cyclotron resonance heating...

  9. Simulation on the electronic wave packet cyclotron motion in a Weyl semimetal slab.

    Science.gov (United States)

    Yao, Haibo; Zhu, Mingfeng; Jiang, Liwei; Zheng, Yisong

    2017-04-20

    We perform a numerical simulation on the time evolution of an electronic wave packet in a Weyl semimetal (WSM) slab driven by a magnetic field. We find that the evolution trajectory of the wave packet depends sensitively on its initial spin state. Only with initial spin state identical to that of the Fermi arc state at the surface it localized, does the wave packet evolution demonstrate the characteristic cyclotron orbit of WSM previously predicted from a semiclassical viewpoint. By analyzing the eigen-expansion of the electronic wave packet, we find the chiral Landau levels (LLs) of the WSM slab, as ingredients of the wave packet, to be responsible for establishing the characteristic WSM cyclotron orbit. In contrast, the nonchiral LLs contribute irregular oscillations to the wave packet evolution, going against the formation of a well-defined cyclotron orbit. In addition, the tilted magnetic field does not affect the motion of the electronic wave packet along the Fermi arcs in the momentum space. It does, however, alter the evolution trajectory of the electronic wave packet in real space and spin space. Finally, the energy disalignment of the Weyl nodes results in a 3D cyclotron orbit in real space.

  10. Closure of the single fluid magnetohydrodynamic equations in presence of electron cyclotron current drive

    NARCIS (Netherlands)

    Westerhof, E.; Pratt, J.

    2014-01-01

    In the presence of electron cyclotron current drive (ECCD), the Ohm's law of single fluid magnetohydrodynamics is modified as E + v × B = η(J – J EC). This paper presents a new closure relation for the EC driven current density appearing in this modified Ohm's law. The new relation

  11. Advanced launcher design options for electron cyclotron current drive on ITER based on remote steering

    NARCIS (Netherlands)

    Graswinckel, M. R.; Bongers, W. A.; M.R. de Baar,; van den Berg, M. A.; Denisov, G.; Donne, A. J. H.; Elzendoorn, B. S. Q.; Goede, A. P. H.; Heidinger, R.; Kuzikov, S.; Kruijt, O. G.; Kruizinga, B.; Moro, A.; Poli, E.; Ronden, D. M. S.; Saibene, G.; Thoen, D. J.; Verhoeven, A. G. A.

    2008-01-01

    Electron cyclotron current drive will become the main scheme on ITER for the stabilization of neoclassical tearing modes (NTMs) and the control of sawtooth oscillations. The effectiveness of this scheme forms the basis for the requirements of the ITER Upper Port Launcher. These requirements include

  12. Techniques and mechanisms applied in electron cyclotron resonance sources for highly charged ions

    NARCIS (Netherlands)

    Drentje, AG

    Electron cyclotron resonance ion sources are delivering beams of highly charged ions for a wide range of applications in many laboratories. For more than two decades, the development of these ion sources has been to a large extent an intuitive and experimental enterprise. Much effort has been spent

  13. Abrupt variation in ion current with biased disk voltage in the electron cyclotron resonance ion source

    NARCIS (Netherlands)

    Taki, GS; Sarma, PR; Chakraborty, DK; Lhandari, RK; Ray, PK; Drentje, AG; Bhandari, R.K.

    The performance of the biased disk in the 6.4 GHz electron cyclotron resonance ion source at VECC, Kolkata was studied at a pressure of similar to 1 X 10(-7) Torr. We observed an abrupt variation of beam current with bias voltage. For low negative bias voltages (from 0 to -5 V) the beam current

  14. Selective minority-ion heating in the afterglow of an electron cyclotron resonance ion source

    NARCIS (Netherlands)

    Nadzeyka, A; Meyer, D; Barzangy, F; Drentje, AG; Wiesemann, K

    We report first experimental results on selective minority-ion heating in the afterglow mode of electron cyclotron resonance ion sources in Bochum and at the KVI (Groningen) in mixtures of Ar/O/He and in pure nitrogen. In addition we measured time resolved vacuum ultraviolet-line intensities of

  15. Isotopic anomaly for carbon ions in an electron cyclotron resonance ion source

    NARCIS (Netherlands)

    Drentje, A. G.; Kitagawa, A.; Muramatsu, M.

    In many experiments methods were applied to increase the highly charged ion output from an electron cyclotron resonance ion source; the gas-mixing method is still generally being applied. The dominant role of the masses of the ions in the gas-mixture was apparent. Two basically differing mechanisms

  16. An overview of control system for the ITER electron cyclotron system

    NARCIS (Netherlands)

    Purohit, D.; Bigelow, T.; Billava, D.; Bonicelli, T.; Caughman, J.; Darbos, C.; Denisov, G.; Gandini, F.; Gassmann, T.; Henderson, M.; Journeux, J. Y.; Kajiwara, K.; Kobayashi, N.; Nazare, C.; Oda, Y.; Omori, T.; Rao, S. L.; Rasmussen, D.; Ronden, D.; Saibene, G.; Sakamoto, K.; Sartori, F.; Takahashi, K.; Temkin, R.

    2011-01-01

    The ITER electron cyclotron (EC) system having capability of up to 26 MW generated power at 170 GHz is being procured by 5 domestic agencies via 10 procurement arrangements. This implies diverse types of equipment and complex interface management. It also places a challenge on control system

  17. A remotely steered millimetre wave launcher for electron cyclotron heating and current drive on ITER

    NARCIS (Netherlands)

    Bongers, W. A.; M. F. Graswinckel,; Goede, A. P. H.; Kasparek, W.; Danilov, I.; Curto, A. F.; M.R. de Baar,; van den Berg, M. A.; Donne, A. J. H.; Elzendoorn, B. S. Q.; Heidinger, R.; Ivanov, P.; Kruijt, O. G.; Lamers, B.; Meier, A.; Piosczyk, B.; Plaum, B.; Ronden, D. M. S.; Thoen, D. J.; Schmid, M.; Verhoeven, A. G. A.

    2010-01-01

    High-power millimetre wave beams employed on ITER for heating and Current drive at the 170 GHz electron cyclotron resonance frequency require agile steering and tight focusing of the beams to suppress neoclassical tearing modes. This paper presents experimental validation of the remote steering (RS)

  18. Development of an 18 GHz superconducting electron cyclotron resonance ion source at RCNP.

    Science.gov (United States)

    Yorita, Tetsuhiko; Hatanaka, Kichiji; Fukuda, Mitsuhiro; Kibayashi, Mitsuru; Morinobu, Shunpei; Okamura, Hiroyuki; Tamii, Atsushi

    2008-02-01

    An 18 GHz superconducting electron cyclotron resonance ion source has recently been developed and installed in order to extend the variety and the intensity of ions at the RCNP coupled cyclotron facility. Production of several ions such as O, N, Ar, Kr, etc., is now under development and some of them have already been used for user experiments. For example, highly charged heavy ion beams like (86)Kr(21+,23+) and intense (16)O(5+,6+) and (15)N(6+) ion beams have been provided for experiments. The metal ion from volatile compounds method for boron ions has been developed as well.

  19. Calibration and use cases of the electron cyclotron emission diagnostic at Wendelstein 7-X

    Energy Technology Data Exchange (ETDEWEB)

    Hoefel, Udo; Hirsch, Matthias; Ewert, Karsten; Hartfuss, Hans-Juergen; Laqua, Heinrich Peter; Stange, Torsten; Wolf, Robert [Max-Planck-Institut fuer Plasmaphysik, Greifswald (Germany); Collaboration: the W7-X Team

    2016-07-01

    The world's largest stellarator, Wendelstein 7-X (W7-X), is equipped with a 140 GHz electron cyclotron resonance heating (ECRH) system providing up to 5 MW absorbed power in the first operation phase OP1.1. The foreseen X2-heating scenario uses the high absorption of the second harmonic extraordinary electron cyclotron waves, which leads on the other hand to a black body electron cyclotron emission (ECE) being proportional to the local electron temperature. ECE is one of the fundamental operating diagnostics and is planned to yield the electron temperature profile from the very first discharges onwards. Unlike most other ECE diagnostics, the 32 channel ECE radiometer diagnostic (with additional 16 channels with higher radial resolution) at W7-X is absolutely calibrated. It is planned to use this diagnostic for intensive studies on electron heat transport in the upcoming operational phases of W7-X. Simple switch-off experiments for the determination of the energy confinement time should already be possible within the first plasma shots. Due to the high temporal and radial resolution the ECE will be used also to determine the power deposition by modulation of the heating gyrotron. or the localization of a power modulated ECRH to optimize the power deposition. If reasonably equilibrated plasma conditions could be generated in the first operational phase (OP 1.1), first studies on electron thermal diffusivity could also be possible.

  20. Characteristics of heat flux and electromagnetic electron-cyclotron instabilities driven by solar wind electrons

    Science.gov (United States)

    Saeed, Sundas; Yoon, P. H.; Sarfraz, M.; Qureshi, M. N. S.

    2017-04-01

    In situ observations reveal the existence of electron velocity distribution function in the solar wind, where the net distribution can be modelled by a combination of core, halo and strahl. These components often possess a relative drift and with respective temperature anisotropies. The relative drift between the core and halo components leads to heat flux (HF) instability, while temperature anisotropies drive electromagnetic electron-cyclotron (EMEC) instability. These instabilities have been separately studied in the literature, but for the first time, the present study combines both unstable modes in the presence of two free energy sources, namely, excessive parallel pressure and excessive perpendicular temperature. HF instability (which is a left-hand circularly polarized mode) is effectively similar to electron firehose instability, except that the free energy is provided by net relative drift among two component electrons in the background of protons. The HF instability is discussed here along with (the right-hand polarized) EMEC instability driven by temperature anisotropy. The unstable HF mode is conventionally termed the 'whistler' HF instability, but it is actually polarized in the opposite sense to the whistler wave. EMEC mode, on the other hand, reduces to the proper whistler wave in the absence of free energy source. The present combined analysis clarifies the polarization characteristics of these two modes in an unambiguous manner.

  1. The design of a correlation electron cyclotron emission system on J-TEXT

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Z. J.; Xiao, Y.; Ma, X. D.; Pan, X. M.; Xiao, J. S. [State Key Laboratory of Advanced Electromagnetic Engineering and Technology, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan 430074 (China)

    2015-04-15

    To study the anomalous transport, a correlation electron cyclotron emission (CECE) was planned to be developed on J-TEXT for electron temperature fluctuation measurement. The spectral decorrelation method was employed for the CECE system. It was developed based on the previous 16-channel electron cyclotron emission system. They shared the optical transmission line and mixer. The CECE part consists of 4 channels. Two fixed frequency narrow band filters were used for two channels and two yttrium iron garnet (YIG) filters for the other two channels. To meet the measuring requirement, some tests have been taken for the YIG filters. The results show good performance of the filters. Gaussian optics is used to produce a good poloidal resolution. Wavenumbers resolved by the CECE diagnostic are k{sub θ} ≤ 1.5 rad/cm and k{sub r} ≤ 12 rad/cm. Some preliminary experiment results are also presented in this paper.

  2. Increase of the performances of electron cyclotron resonance ion sources by using cold electron emission

    CERN Document Server

    Schaechter, I; Badescu-Singureanu, A I; Stiebing, K E; Runkel, S; Hohn, O; Schmidt, L; Schmidt-Böcking, H; Drentje, A; Rodríguez, G

    2003-01-01

    The possibility of a significant increase of the high charge state ion beams delivered by electron cyclotron resonance (ECR) ion sources was approached in IFIN-HH, Bucharest, Romania by a new method. It consists in the introduction in the plasma chamber of the ECR ion source of a metal-dielectric (MD) structure characterized by very high secondary electron emission properties. The intensities of argon ion beams extracted from the 14 GHz ECR ion sources of IKF, Frankfurt/Main, Germany and KVI, Groningen, Netherlands were measured both in the standard mode of operation of the sources and in the presence of a MD structure. Similar results were obtained in both experiments when the MD structure was used showing a net shift of the beam intensity towards higher charge states as compared with the usual standard plasma chamber of the ECR ion sources. Ion current enhancement factors of up to two orders of magnitude were obtained for Ar sup 1 sup 6 sup + ions. (authors)

  3. Studies on a Q/A selector for the SECRAL electron cyclotron resonance ion source.

    Science.gov (United States)

    Yang, Y; Sun, L T; Feng, Y C; Fang, X; Lu, W; Zhang, W H; Cao, Y; Zhang, X Z; Zhao, H W

    2014-08-01

    Electron cyclotron resonance ion sources are widely used in heavy ion accelerators in the world because they are capable of producing high current beams of highly charged ions. However, the design of the Q/A selector system for these devices is challenging, because it must have a sufficient ion resolution while controlling the beam emittance growth. Moreover, this system has to be matched for a wide range of ion beam species with different intensities. In this paper, research on the Q/A selector system at the SECRAL (Superconducting Electron Cyclotron Resonance ion source with Advanced design in Lanzhou) platform both in experiment and simulation is presented. Based on this study, a new Q/A selector system has been designed for SECRAL II. The features of the new design including beam simulations are also presented.

  4. Results of RIKEN superconducting electron cyclotron resonance ion source with 28 GHz.

    Science.gov (United States)

    Higurashi, Y; Ohnishi, J; Nakagawa, T; Haba, H; Tamura, M; Aihara, T; Fujimaki, M; Komiyama, M; Uchiyama, A; Kamigaito, O

    2012-02-01

    We measured the beam intensity of highly charged heavy ions and x-ray heat load for RIKEN superconducting electron cyclotron resonance ion source with 28 GHz microwaves under the various conditions. The beam intensity of Xe(20+) became maximum at B(min) ∼ 0.65 T, which was ∼65% of the magnetic field strength of electron cyclotron resonance (B(ECR)) for 28 GHz microwaves. We observed that the heat load of x-ray increased with decreasing gas pressure and field gradient at resonance zone. It seems that the beam intensity of highly charged heavy ions with 28 GHz is higher than that with 18 GHz at same RF power.

  5. Understanding the bursty electron cyclotron emission during a sawtooth crash in the HT-7 tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Li, Erzhong, E-mail: rzhonglee@ipp.ac.cn; Hu, Liqun; Chen, Kaiyun [Institute of Plasma Physics, Chinese Academy of Science, Hefei 230031 (China)

    2014-01-15

    Bursts in electron cyclotron emission (ECE) were observed during sawtooth crashes in HT-7 in discharges with ion cyclotron resonance heating injected near the q = 1 rational surface (q is the safety factor). The local ECE measurement indicated that the bursty radiation is only observed on channels near but a little away outward from the q = 1 magnetic surface. In conjunction with the soft x-ray tomography analysis, it was determined that, for the first time, only a compression process survives in the later stage of fast magnetic reconnection but before prompt heat transport. The compression enhanced the electron radiation temperature, the increased amplitude of which agreed well with the estimation according to a kinetic compression theory model [R. J. Hastie and T. C. Hender, Nucl. Fusion 28, 585 (1988)]. This paper presents the experimental evidence that there indeed exists a transient compression phase which results in the bursty ECE radiation during a sawtooth crash.

  6. Understanding the bursty electron cyclotron emission during a sawtooth crash in the HT-7 tokamak

    Science.gov (United States)

    Li, Erzhong; Hu, Liqun; Chen, Kaiyun

    2014-01-01

    Bursts in electron cyclotron emission (ECE) were observed during sawtooth crashes in HT-7 in discharges with ion cyclotron resonance heating injected near the q = 1 rational surface (q is the safety factor). The local ECE measurement indicated that the bursty radiation is only observed on channels near but a little away outward from the q = 1 magnetic surface. In conjunction with the soft x-ray tomography analysis, it was determined that, for the first time, only a compression process survives in the later stage of fast magnetic reconnection but before prompt heat transport. The compression enhanced the electron radiation temperature, the increased amplitude of which agreed well with the estimation according to a kinetic compression theory model [R. J. Hastie and T. C. Hender, Nucl. Fusion 28, 585 (1988)]. This paper presents the experimental evidence that there indeed exists a transient compression phase which results in the bursty ECE radiation during a sawtooth crash.

  7. Parametric decay instability of an obliquely propagating ordinary wave in the electron cyclotron frequency range

    Science.gov (United States)

    Gusakov, E. Z.; Popov, A. Yu.

    2018-01-01

    The possibility of the low-power-threshold parametric decay of an obliquely propagating ordinary wave to an upper hybrid wave and a low-hybrid wave is analysed under conditions of nonmonotonic plasma density profile in a magnetic trap. The instability threshold and growth rate are derived explicitly. The analytical results are illustrated under the conditions typical of the ordinary mode fundamental electron cyclotron resonance heating harmonic experiments at the FTU tokamak.

  8. Observation of quasi-periodic frequency sweeping in electron cyclotron emission of nonequilibrium mirror-confined plasma

    CERN Document Server

    Viktorov, M E; Mansfeld, D A; Golubev, S V

    2016-01-01

    Chirping frequency patterns have been observed in the electron cyclotron emission from strongly nonequilibrium plasma confined in a table-top mirror magnetic trap. Such patterns are typical for the formation of nonlinear phase space structures in a proximity of the wave-particle resonances of a kinetically unstable plasma, also known as the "holes and clumps" mechanism. Our data provides the first experimental evidence for acting of this mechanism in the electron cyclotron frequency domain.

  9. Electron Cloud Cyclotron Resonances in the Presence of a Short-bunch-length Relativistic Beam

    Energy Technology Data Exchange (ETDEWEB)

    Celata, C.M.; Furman, Miguel A.; Vay, J.-L.; Yu, Jennifer W.

    2008-09-02

    Computer simulations using the 2D code"POSINST" were used to study the formation of the electron cloud in the wiggler section of the positron damping ring of the International Linear Collider. In order to simulate an x-y slice of the wiggler (i.e., a slice perpendicular to the beam velocity), each simulation assumed a constant vertical magnetic field. At values of the magnetic field where the cyclotron frequency was an integral multiple of the bunch frequency, and where the field strength was less than approximately 0.6 T, equilibrium average electron densities were up to three times the density found at other neighboring field values. Effects of this resonance between the bunch and cyclotron frequency are expected to be non-negligible when the beam bunch length is much less than the product of the electron cyclotron period and the beam velocity, for a beam moving at v~;;c. Details of the dynamics of the resonance are described.

  10. Wave intensifications near the electron cyclotron frequency within the polar cusp

    Science.gov (United States)

    Farrell, W. M.; Gurnett, D. A.; Menietti, J. D.; Wong, H. K.; Lin, C. S.

    1990-01-01

    As DE 1 flew through the polar cusp, enhanced narrowband electrostatic waves were sometimes observed just above the electron cyclotron frequency. Here, wave and particle measurements from three representative cusp transits are presented in order to characterize these signals and understand the conditions that favor their generation. It was found that the form of the local cusp electron velocity distribution had a direct influence on the wave spectral character. A preliminary study indicates that electron beams in the cusp can generate the enhanced signals, although generation by an anisotropic warm component cannot be ruled out.

  11. Electron acceleration at Jupiter: input from cyclotron-resonant interaction with whistler-mode chorus waves

    Directory of Open Access Journals (Sweden)

    E. E. Woodfield

    2013-10-01

    Full Text Available Jupiter has the most intense radiation belts of all the outer planets. It is not yet known how electrons can be accelerated to energies of 10 MeV or more. It has been suggested that cyclotron-resonant wave-particle interactions by chorus waves could accelerate electrons to a few MeV near the orbit of Io. Here we use the chorus wave intensities observed by the Galileo spacecraft to calculate the changes in electron flux as a result of pitch angle and energy diffusion. We show that, when the bandwidth of the waves and its variation with L are taken into account, pitch angle and energy diffusion due to chorus waves is a factor of 8 larger at L-shells greater than 10 than previously shown. We have used the latitudinal wave intensity profile from Galileo data to model the time evolution of the electron flux using the British Antarctic Survey Radiation Belt (BAS model. This profile confines intense chorus waves near the magnetic equator with a peak intensity at ∼5° latitude. Electron fluxes in the BAS model increase by an order of magnitude for energies around 3 MeV. Extending our results to L = 14 shows that cyclotron-resonant interactions with chorus waves are equally important for electron acceleration beyond L = 10. These results suggest that there is significant electron acceleration by cyclotron-resonant interactions at Jupiter contributing to the creation of Jupiter's radiation belts and also increasing the range of L-shells over which this mechanism should be considered.

  12. Electrostatic Electron Cyclotron Waves Observed by the Plasma Wave Instrument on Board Polar

    Science.gov (United States)

    Menietti, J. D.; Pickett, J. S.; Gurnett, D. A.; Scudder, J. D.

    2001-01-01

    We report the results of an investigation of waves observed by the Polar spacecraft at high altitudes and latitudes and at frequencies just above the cyclotron frequency. These observations are made frequently when the spacecraft is over the polar cap as well as near the dayside cusp and near the nightside auroral region, and observations are made for ratios of plasma frequency to cyclotron frequency, f(sub p)/f(sub c) = 1. Using the six-channel high-frequency waveform receiver (HFWR) on board the spacecraft, which can provide three-axis electric and three-axis magnetic field measurements, we attempt to identify the wavemode of these emissions and investigate possible source mechanisms including low-energy electron beams. We further observe electromagnetic emission associated with upper hybrid waves near and within the plasmasphere. This emission is consistent with both Z and O modes.

  13. Stochastic heating in the cyclotron resonance of electrons; Calentamiento estocastico en la resonancia ciclotronica de los electrones

    Energy Technology Data Exchange (ETDEWEB)

    Gutierrez T, C.; Hernandez A, O. [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    1999-07-01

    The study of the different schemes of plasma heating by radiofrequency waves is a very actual problem related with the plasma heating in different machines and the particle acceleration mechanisms. In this work, it is obtained the expression for the temporal evolution of the energy absorbed in the cyclotron resonance of electrons where it is showed the stochastic character of the energy absorption. It is obtained the stochastic criteria in a magnetic configuration of an Ecr type plasma source. (Author)

  14. A multi-sample changer coupled to an electron cyclotron resonance source for accelerator mass spectrometry experiments.

    Science.gov (United States)

    Vondrasek, R; Palchan, T; Pardo, R; Peters, C; Power, M; Scott, R

    2014-02-01

    A new multi-sample changer has been constructed allowing rapid changes between samples. The sample changer has 20 positions and is capable of moving between samples in 1 min. The sample changer is part of a project using Accelerator Mass Spectrometry (AMS) at the Argonne Tandem Linac Accelerator System (ATLAS) facility to measure neutron capture rates on a wide range of actinides in a reactor environment. This project will require the measurement of a large number of samples previously irradiated in the Advanced Test Reactor at Idaho National Laboratory. The AMS technique at ATLAS is based on production of highly charged positive ions in an electron cyclotron resonance ion source followed by acceleration in the ATLAS linac. The sample material is introduced into the plasma via laser ablation chosen to limit the dependency of material feed rates upon the source material composition as well as minimize cross-talk between samples.

  15. The electron-cyclotron maser instability as a source of plasma radiation. [Solar radio bursts

    Science.gov (United States)

    Winglee, R. M.; Dulk, G. A.

    1986-01-01

    The generation of continuum bursts from the sun at dm and m wavelengths (in particular, type IV bursts) via the electron-cyclotron-maser instability is examined. The maser instability can be driven by an electron distribution with either a loss-cone anisotropy or a peak at large pitch angles. For omega(p)/Omega(e) much greater than 1, the maser emission is produced by electrons interacting through a harmonic (cyclotron) resonance and is electrostatic, being in the upper hybrid mode at frequencies approximately equal to omega(p). Coalescence processes are required to convert the electrostatic waves into transverse radiation which can escape from the source region. Whether the resultant spectrum is nearly a smooth continuum or has a zebra-stripe pattern (both of which occur in type IV bursts) depends on the form of the electron distribution, inhomogeneities in the density and magnetic field, and whether the maser reaches saturation. For at least the case of some type IV dm bursts with fine structure, comparison with observations seems to indicate that the electrons producing the emission are more likely to have a loss-cone distribution, and that the maser instability is not at saturation.

  16. Electron cyclotron heating and supra-thermal electron dynamics in the TCV Tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Gnesin, S.

    2011-10-15

    This thesis is concerned with the physics of supra-thermal electrons in thermonuclear, magnetically confined plasmas. Under a variety of conditions, in laboratory as well as space plasmas, the electron velocity distribution function is not in thermodynamic equilibrium owing to internal or external drives. Accordingly, the distribution function departs from the equilibrium Maxwellian, and in particular generally develops a high-energy tail. In tokamak plasmas, this occurs especially as a result of injection of high-power electromagnetic waves, used for heating and current drive, as well as a result of internal magnetohydrodynamic (MHD) instabilities. The physics of these phenomena is intimately tied to the properties and dynamics of this supra-thermal electron population. This motivates the development of instrumental apparatus to measure its properties as well as of numerical codes to simulate their dynamics. Both aspects are reflected in this thesis work, which features advanced instrumental development and experimental measurements as well as numerical modeling. The instrumental development consisted of the complete design of a spectroscopic and tomographic system of four multi-detector hard X-ray (HXR) cameras for the TCV tokamak. The goal is to measure bremsstrahlung emission from supra-thermal electrons with energies in the 10-300 keV range, with the ultimate aim of providing the first full tomographic reconstruction at these energies in a noncircular plasma. In particular, supra-thermal electrons are generated in TCV by a high-power electron cyclotron heating (ECH) system and are also observed in the presence of MHD events, such as sawtooth oscillations and disruptive instabilities. This diagnostic employs state-of-the-art solid-state detectors and is optimized for the tight space requirements of the TCV ports. It features a novel collimator concept that combines compactness and flexibility as well as full digital acquisition of the photon pulses, greatly

  17. Modeling of electron cyclotron resonance acceleration in a stationary inhomogeneous magnetic field

    Directory of Open Access Journals (Sweden)

    Valeri D. Dougar-Jabon

    2008-04-01

    Full Text Available In this paper, the cyclotron autoresonance acceleration of electrons in a stationary inhomogeneous magnetic field is studied. The trajectory and energy of electrons are found through a numerical solution of the relativistic Newton-Lorentz equation by a finite difference method. The electrons move along a TE_{112} cylinder cavity in a steady-state magnetic field whose axis coincides with the cavity axis. The magnetic field profile is such that it keeps the phase difference between the electric microwave field and the electron velocity vector within the acceleration phase band. The microwaves amplitude of 6  kV/cm is used for numerical calculations. It is shown that an electron with an initial longitudinal energy of 8 keV can be accelerated up to 260 keV by 2.45 GHz microwaves at a distance of 17 cm.

  18. Electron cyclotron resonance near the axis of the gas-dynamic trap

    Science.gov (United States)

    Bagulov, D. S.; Kotelnikov, I. A.

    2012-08-01

    Propagation of an extraordinary electromagnetic wave in the vicinity of electron cyclotron resonance surface in an open linear trap is studied analytically, taking into account inhomogeneity of the magnetic field in paraxial approximation. Ray trajectories are derived from a reduced dispersion equation that makes it possible to avoid the difficulty associated with a transition from large propagation angles to the case of strictly longitudinal propagation. Our approach is based on the theory, originally developed by Zvonkov and Timofeev [Sov. J. Plasma Phys. 14, 743 (1988)], who used the paraxial approximation for the magnetic field strength, but did not consider the slope of the magnetic field lines, which led to considerable error, as has been recently noted by Gospodchikov and Smolyakova [Plasma Phys. Rep. 37, 768-774 (2011)]. We have found ray trajectories in analytic form and demonstrated that the inhomogeneity of both the magnetic field strength and the field direction can qualitatively change the picture of wave propagation and significantly affect the efficiency of electron cyclotron heating of a plasma in a linear magnetic trap. Analysis of the ray trajectories has revealed a criterion for the resonance point on the axis of the trap to be an attractor for the ray trajectories. It is also shown that a family of ray trajectories can still reach the resonance point on the axis if the latter generally repels the ray trajectories. As an example, results of general theory are applied to the electron cyclotron resonance heating experiment which is under preparation on the gas dynamic trap in the Budker Institute of Nuclear Physics [Shalashov et al., Phys. Plasmas 19, 052503 (2012)].

  19. Improved system for perpendicular electron-cyclotron emission measurements on TMX-Upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Lasnier, C.J.; Ellis, R.F.; James, R.A.

    1986-03-07

    Perpendicular electron-cyclotron emission (PECE) is used on TMX-U to diagnose thermal-barrier hot electrons (T/sub H/ approx. 100 to 400 keV); yielding the time history of the temperature of these relativistic electrons. We describe an improved quasi-optical viewing system for these measurements that uses high sensitivity superheterodyne receivers at fixed frequencies of 60, 98, 130, and 196 GHz. The improved viewing and transport system consists of an off-axis ellipsoidal mirror that images the plasma onto a V-band conical collection horn, an overmoded circular waveguide (7/8'' diam) that transports the radiation outside the vacuum vessel where the polarization is selected, and a high absorptivity Macor beam dump to prevent internal wall reflections from entering the viewing system. A relativistic code is used to calculate optically thin PECE signals from relativistic electrons for various energy and pitch angle distributions. 4 refs., 4 figs.

  20. Physics design of the in-vessel collection optics for the ITER electron cyclotron emission diagnostic.

    Science.gov (United States)

    Rowan, W L; Houshmandyar, S; Phillips, P E; Austin, M E; Beno, J H; Hubbard, A E; Khodak, A; Ouroua, A; Taylor, G

    2016-11-01

    Measurement of the electron cyclotron emission (ECE) is one of the primary diagnostics for electron temperature in ITER. In-vessel, in-vacuum, and quasi-optical antennas capture sufficient ECE to achieve large signal to noise with microsecond temporal resolution and high spatial resolution while maintaining polarization fidelity. Two similar systems are required. One views the plasma radially. The other is an oblique view. Both views can be used to measure the electron temperature, while the oblique is also sensitive to non-thermal distortion in the bulk electron distribution. The in-vacuum optics for both systems are subject to degradation as they have a direct view of the ITER plasma and will not be accessible for cleaning or replacement for extended periods. Blackbody radiation sources are provided for in situ calibration.

  1. Status of the Bio-Nano electron cyclotron resonance ion source at Toyo University

    Energy Technology Data Exchange (ETDEWEB)

    Uchida, T., E-mail: uchida-t@toyo.jp [Bio-Nano Electronics Research Centre, Toyo University, Kawagoe 350-8585 (Japan); Minezaki, H.; Ishihara, S. [Graduate School of Engineering, Toyo University, Kawagoe 350-8585 (Japan); Muramatsu, M.; Kitagawa, A.; Drentje, A. G. [National Institute of Radiological Sciences (NIRS), Chiba 263-8555 (Japan); Rácz, R.; Biri, S. [Institute for Nuclear Research (ATOMKI), H-4026 Debrecen (Hungary); Asaji, T. [Oshima National College of Maritime Technology, Yamaguchi 742-2193 (Japan); Kato, Y. [Graduate School of Engineering, Osaka University, Suita 565-0871 (Japan); Yoshida, Y. [Bio-Nano Electronics Research Centre, Toyo University, Kawagoe 350-8585 (Japan); Graduate School of Engineering, Toyo University, Kawagoe 350-8585 (Japan)

    2014-02-15

    In the paper, the material science experiments, carried out recently using the Bio-Nano electron cyclotron resonance ion source (ECRIS) at Toyo University, are reported. We have investigated several methods to synthesize endohedral C{sub 60} using ion-ion and ion-molecule collision reaction in the ECRIS. Because of the simplicity of the configuration, we can install a large choice of additional equipment in the ECRIS. The Bio-Nano ECRIS is suitable not only to test the materials production but also to test technical developments to improve or understand the performance of an ECRIS.

  2. Fullerene-rare gas mixed plasmas in an electron cyclotron resonance ion source

    Energy Technology Data Exchange (ETDEWEB)

    Asaji, T., E-mail: asaji@oshima-k.ac.jp; Ohba, T. [Oshima National College of Maritime Technology, 1091-1 Komatsu, Suo-oshima, Oshima, Yamaguchi 742-2193 (Japan); Uchida, T.; Yoshida, Y. [Bio-Nano Electronics Research Centre, Toyo University, 2100 Kujirai, Kawagoe, Saitama 350-8585 (Japan); Minezaki, H.; Ishihara, S. [Graduate School of Engineering, Toyo University, 2100 Kujirai, Kawagoe, Saitama 350-8585 (Japan); Racz, R.; Biri, S. [Institute of Nuclear Research (ATOMKI), H-4026 Debrecen, Bem Tér 18/c (Hungary); Muramatsu, M.; Kitagawa, A. [National Institute of Radiological Sciences (NIRS), 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan); Kato, Y. [Graduate School of Engineering, Osaka University, 2-1 Yamada-oka, Suita, Osaka 565-0871 (Japan)

    2014-02-15

    A synthesis technology of endohedral fullerenes such as Fe@C{sub 60} has developed with an electron cyclotron resonance (ECR) ion source. The production of N@C{sub 60} was reported. However, the yield was quite low, since most fullerene molecules were broken in the ECR plasma. We have adopted gas-mixing techniques in order to cool the plasma and then reduce fullerene dissociation. Mass spectra of ion beams extracted from fullerene-He, Ar or Xe mixed plasmas were observed with a Faraday cup. From the results, the He gas mixing technique is effective against fullerene destruction.

  3. Development of a prototype T-shaped fast switching device for electron cyclotron current drive systems

    Science.gov (United States)

    Sekiguchi, Kenji; Nagashima, Koji; Honzu, Toshihiko; Saigusa, Mikio; Oda, Yasuhisa; Takahashi, Koji; Sakamoto, Keishi

    2016-09-01

    A T-shaped high-power switching device composed of circular corrugated waveguides with three ports and double dielectric disks made of sapphire was proposed as a fast switching device based on a new principle in electron cyclotron current drive systems. This switching device has the advantages of operating at a fixed frequency and being compact. The design of the prototype switch was obtained by numerical simulations using a finite-difference time-domain (FDTD) method. The size of these components was optimized for the frequency band of 170 GHz. Low-power tests were carried out in a cross-shaped model.

  4. Nonlocal weakly relativistic permittivity tensor of magnetized plasma near electron cyclotron resonances

    Science.gov (United States)

    Sakharov, A. S.

    2017-11-01

    Compact expressions are derived for the nonlocal permittivity tensor of weakly relativistic plasma in a 2D nonuniform magnetic field near the resonances at the second harmonic of the electron cyclotron frequency for an extraordinary wave and at the first harmonic for an ordinary wave. It is shown that the wave equation with allowance for the obtained thermal correction to the permittivity tensor in the form of a differential operator in transverse (with respect to the external magnetic field) coordinates possesses an integral in the form of the energy conservation law.

  5. Calculating method for confinement time and charge distribution of ions in electron cyclotron resonance sources

    Energy Technology Data Exchange (ETDEWEB)

    Dougar-Jabon, V.D. [Escuela de Fisica, Universidad Industrial de Santander, A.A. 678, Bucaramanga (Colombia); Umnov, A.M. [Russian Friendship University, 117198 Moscow (Russia); Kutner, V.B. [Joint Institute for Nuclear Research, Dubna (Russia)

    1996-03-01

    It is common knowledge that the electrostatic pit in a core plasma of electron cyclotron resonance sources exerts strict control over generation of ions in high charge states. This work is aimed at finding a dependence of the lifetime of ions on their charge states in the core region and to elaborate a numerical model of ion charge dispersion not only for the core plasmas but for extracted beams as well. The calculated data are in good agreement with the experimental results on charge distributions and magnitudes for currents of beams extracted from the 14 GHz DECRIS source. {copyright} {ital 1996 American Institute of Physics.}

  6. Development of DRAGON electron cyclotron resonance ion source at Institute of Modern Physics.

    Science.gov (United States)

    Lu, W; Xie, D Z; Zhang, X Z; Xiong, B; Ruan, L; Sha, S; Zhang, W H; Cao, Y; Lin, S H; Guo, J W; Fang, X; Guo, X H; Li, X X; Ma, H Y; Yang, Y; Wu, Q; Zhao, H Y; Ma, B H; Wang, H; Zhu, Y H; Feng, Y C; Li, J Y; Li, J Q; Sun, L T; Zhao, H W

    2012-02-01

    A new room temperature electron cyclotron resonance (ECR) ion source, DRAGON, is under construction at IMP. DRAGON is designed to operate at microwaves of frequencies of 14.5-18 GHz. Its axial solenoid coils are cooled with evaporative medium to provide an axial magnetic mirror field of 2.5 T at the injection and 1.4 T at the extraction, respectively. In comparison to other conventional room temperature ECR ion sources, DRAGON has so far the largest bore plasma chamber of inner diameter of 126 mm with maximum radial fields of 1.4-1.5 T produced by a non-Halbach permanent sextupole magnet.

  7. Effect of pulse-modulated microwaves on fullerene ion production with electron cyclotron resonance ion source.

    Science.gov (United States)

    Asaji, T; Uchida, T; Minezaki, H; Oshima, K; Racz, R; Muramatsu, M; Biri, S; Kitagawa, A; Kato, Y; Yoshida, Y

    2012-02-01

    Fullerene plasmas generated by pulse-modulated microwaves have been investigated under typical conditions at the Bio-Nano electron cyclotron resonance ion source. The effect of the pulse modulation is distinct from that of simply structured gases, and then the density of the fullerene plasmas increased as decreasing the duty ratio. The density for a pulse width of 10 μs at the period of 100 μs is 1.34 times higher than that for CW mode. We have studied the responses of fullerene and argon plasmas to pulsed microwaves. After the turnoff of microwave power, fullerene plasmas lasted ∼30 times longer than argon plasmas.

  8. Preparation of Bismuth Titanate Films by Electron Cyclotron Resonance Plasma Sputtering-Chemical Vapor Deposition

    OpenAIRE

    Masumoto, H.; Hirai, T.

    1995-01-01

    Bismuth titanate (Bi4Ti3O12 : BIT) thin films were prepared on the Pt courted MgO(100) substrate by electron cyclotron resonance plasma sputtering-chemical vapor deposition (ECR plasma sputtering-CVD). Bi2O3 was used as a sputtering target and tetra-isopropoxy-titanium [Ti(i-C3H7O)4] as a CVD source. The composition of films was controlled by changing RF power (PRF) of Bi2O3 target and Ti source temperature (TTi). The stoichiometric BIT film was prepared under the condition of PRF=500W, TTi=6...

  9. Phase-resolved optical emission spectroscopy for an electron cyclotron resonance etcher

    Energy Technology Data Exchange (ETDEWEB)

    Milosavljevic, Vladimir [BioPlasma Research Group, Dublin Institute of Technology, Sackville Place, Dublin 1 (Ireland); Biosystems Engineering, University College Dublin, Dublin 4, Ireland and Faculty of Physics, University of Belgrade, Belgrade (Serbia); MacGearailt, Niall; Daniels, Stephen; Turner, Miles M. [NCPST, Dublin City University, Dublin (Ireland); Cullen, P. J. [BioPlasma Research Group, Dublin Institute of Technology, Sackville Place, Dublin 1 (Ireland)

    2013-04-28

    Phase-resolved optical emission spectroscopy (PROES) is used for the measurement of plasma products in a typical industrial electron cyclotron resonance (ECR) plasma etcher. In this paper, the PROES of oxygen and argon atoms spectral lines are investigated over a wide range of process parameters. The PROES shows a discrimination between the plasma species from gas phase and those which come from the solid phase due to surface etching. The relationship between the micro-wave and radio-frequency generators for plasma creation in the ECR can be better understood by the use of PROES.

  10. Remote-Steering Antennas for 140 GHz Electron Cyclotron Heating of the Stellarator W7-X

    Directory of Open Access Journals (Sweden)

    Lechte C.

    2017-01-01

    Full Text Available For electron cyclotron resonance heating of the stellarator W7-X at IPP Greifswald, a 140 GHz/10 MW cw millimeter wave system has been built. Two out of 12 launchers will employ a remote-steering design. This paper describes the overall design of the two launchers, and design issues like input coupling structures, manufacturing of corrugated waveguides, optimization of the steering range, integration of vacuum windows, mitrebends and vacuum valves into the launchers, as well as low power tests of the finished waveguides.

  11. The third generation superconducting 28 GHz electron cyclotron resonance ion source VENUS (invited)

    Energy Technology Data Exchange (ETDEWEB)

    Lyneis, C.; Leitner, D.; Leitner, M.; Taylor, C.; Abbott, S. [Lawrence Berkeley National Laboratory, One Cyclotron Road, Berkeley, California 94720 (United States)

    2010-02-15

    VENUS is a third generation electron cyclotron resonance (ECR) ion source, which incorporates a high field superconducting NbTi magnet structure, a 28 GHz gryotron microwave source and a state of the art closed cycle cryosystem. During the decade from initial concept to regular operation, it has demonstrated both the feasibility and the performance levels of this new generation of ECR ion sources and required innovation on magnet construction, plasma chamber design, and beam transport. In this paper, the development, performance, and major innovations are described as well as a look to the potential to construct a fourth generation ECR ion source.

  12. Remote-Steering Antennas for 140 GHz Electron Cyclotron Heating of the Stellarator W7-X

    Science.gov (United States)

    Lechte, C.; Kasparek, W.; Plaum, B.; Zeitler, A.; Erckmann, V.; Laqua, H.; Schneider, N.; Weissgerber, M.; Bechtold, A.; Busch, M.; Szepaniak, B.

    2017-07-01

    For electron cyclotron resonance heating of the stellarator W7-X at IPP Greifswald, a 140 GHz/10 MW cw millimeter wave system has been built. Two out of 12 launchers will employ a remote-steering design. This paper describes the overall design of the two launchers, and design issues like input coupling structures, manufacturing of corrugated waveguides, optimization of the steering range, integration of vacuum windows, mitrebends and vacuum valves into the launchers, as well as low power tests of the finished waveguides.

  13. Development of a miniature microwave electron cyclotron resonance plasma ion thruster for exospheric micro-propulsion.

    Science.gov (United States)

    Dey, Indranuj; Toyoda, Yuji; Yamamoto, Naoji; Nakashima, Hideki

    2015-12-01

    A miniature microwave electron cyclotron resonance plasma source [(discharge diameter)/(microwave cutoff diameter) micro-propulsion applications in the exosphere. The discharge source uses both radial and axial magnetostatic field confinement to facilitate electron cyclotron resonance and increase the electron dwell time in the volume, thereby enhancing plasma production efficiency. Performance of the ion thruster is studied at 3 microwave frequencies (1.2 GHz, 1.6 GHz, and 2.45 GHz), for low input powers (<15 W) and small xenon mass flow rates (<40 μg/s), by experimentally measuring the extracted ion beam current through a potential difference of ≅1200 V. The discharge geometry is found to operate most efficiently at an input microwave frequency of 1.6 GHz. At this frequency, for an input power of 8 W, and propellant (xenon) mass flow rate of 21 μg/s, 13.7 mA of ion beam current is obtained, equivalent to an calculated thrust of 0.74 mN.

  14. Production of hydrogen and deuterium negative ions in an electron cyclotron resonance driven plasma

    Energy Technology Data Exchange (ETDEWEB)

    Dougar-Jabon, V.D. [Industrial Univ. of Santander, Bucaramanga (Colombia)

    2001-04-01

    An electron cyclotron resonance source with driven plasma rings for hydrogen isotope ion production is studied. Extracted currents of positive and negative ions depending on gas pressure, microwave power value and extraction voltage are obtained. The study shows that the negative ion yield is an order of magnitude higher than the yield of positive particles when a driven ring is in contact with the surface of the plasma electrode. The production of negative ions of deuterium, D{sup -}, is close to the production of negative ions of light hydrogen isotope, H{sup -}. The comparison of the experimental data with the calculated ones shows that the most probable process of the H{sup -} and D{sup -} ion formation in the electron cyclotron driven plasma is dissociative attachment of electrons to molecules in high Rydberg states. For hydrogen ions and ions of deuterium, the negative current at a microwave power of 200 W through a 3-mm aperture and 8 kV extraction voltage are 4.7 mA and 3.1 mA respectively. (orig.)

  15. Ultrathin oxide grown on polysilicon by using an electron cyclotron resonance N sub 2 O plasma

    CERN Document Server

    Han, S Y

    2000-01-01

    We have developed a process for growing ultrathin oxide on a polysilicon layer by using an electron cyclotron resonance (ECR) N sub 2 O plasma. Sub-4-nm thick polyoxides were grown on n sup + and p sup + polysilicon layers and were characterized. These oxides had larger breakdown fields, smaller electron trapping characteristics, and larger Q sub B sub D values than those of thermal polyoxides. The electron trapping characteristics of ECR N sub 2 O plasma polyoxides, which were smaller than those of thermal polyoxides at positive bias, resulted from the smaller roughness of the polysilicon surface after the oxidation process. Under a negative constant-current stress of 20 mA/cm sup 2 for polyoxide on p sup + polysilicon were obtained. These ultrathin plasma polyoxides would be good candidates for future inter-poly dielectrics and gate oxides for thin film transistors.

  16. A relativistic model of electron cyclotron current drive efficiency in tokamak plasmas

    Directory of Open Access Journals (Sweden)

    Lin-Liu Y.R.

    2012-09-01

    Full Text Available A fully relativistic model of electron cyclotron current drive (ECCD efficiency based on the adjoint function techniques is considered. Numerical calculations of the current drive efficiency in a tokamak by using the variational approach are performed. A fully relativistic extension of the variational principle with the modified basis functions for the Spitzer function with momentum conservation in the electron-electron collision is described in general tokamak geometry. The model developed has generalized that of Marushchenko’s (N.B . Marushchenko, et al. Fusion Sci. & Tech., 2009, which is extended for arbitrary temperatures and covers exactly the asymptotic for u ≫ 1 when Z → ∞, and suitable for ray-tracing calculations.

  17. Electron cyclotron resonance ion source plasma characterization by energy dispersive x-ray imaging

    Science.gov (United States)

    Rácz, R.; Mascali, D.; Biri, S.; Caliri, C.; Castro, G.; Galatà, A.; Gammino, S.; Neri, L.; Pálinkás, J.; Romano, F. P.; Torrisi, G.

    2017-07-01

    Pinhole and CCD based quasi-optical x-ray imaging technique was applied to investigate the plasma of an electron cyclotron resonance ion source (ECRIS). Spectrally integrated and energy resolved images were taken from an axial perspective. The comparison of integrated images taken of argon plasma highlights the structural changes affected by some ECRIS setting parameters, like strength of the axial magnetic confinement, RF frequency and microwave power. Photon counting analysis gives precise intensity distribution of the x-ray emitted by the argon plasma and by the plasma chamber walls. This advanced technique points out that the spatial positions of the electron losses are strongly determined by the kinetic energy of the electrons themselves to be lost and also shows evidences how strongly the plasma distribution is affected by slight changes in the RF frequency.

  18. Three-dimensional simulations of ion dynamics in the plasma of an electron cyclotron resonance ion source

    NARCIS (Netherlands)

    Mironov, V.; Beijers, J.P.M.

    The ion production in an electron cyclotron resonance ion source (ECRIS) is modeled using a particle-in-cell Monte-Carlo-collision code in a three-dimensional geometry. Only the heavy particles (ions and atoms) are tracked, while the electrons are represented using a Maxwell-Boltzmann energy

  19. Cyclotron waves in plasma

    CERN Document Server

    Lominadze, D G

    2013-01-01

    Cyclotron Waves in Plasma is a four-chapter text that covers the basic physical concepts of the theory of cyclotron waves and cyclotron instabilities, brought about by the existence of steady or alternating plasma currents flowing perpendicular to the magnetic field.This book considers first a wide range of questions associated with the linear theory of cyclotron oscillations in equilibrium plasmas and in electron plasmas in metals and semiconductors. The next chapter deals with the parametric excitation of electron cyclotron oscillations in plasma in an alternating electric field. A chapter f

  20. Extension of electron cyclotron heating at ASDEX Upgrade with respect to high density operation

    Science.gov (United States)

    Schubert, Martin; Stober, Jörg; Herrmann, Albrecht; Kasparek, Walter; Leuterer, Fritz; Monaco, Francesco; Petzold, Bernhard; Plaum, Burkhard; Vorbrugg, Stefan; Wagner, Dietmar; Zohm, Hartmut

    2017-10-01

    The ASDEX Upgrade electron cyclotron resonance heating operates at 105 GHz and 140 GHz with flexible launching geometry and polarization. In 2016 four Gyrotrons with 10 sec pulse length and output power close to 1 MW per unit were available. The system is presently being extended to eight similar units in total. High heating power and high plasma density operation will be a part of the future ASDEX Upgrade experiment program. For the electron cyclotron resonance heating, an O-2 mode scheme is proposed, which is compatible with the expected high plasma densities. It may, however, suffer from incomplete single-pass absorption. The situation can be improved significantly by installing holographic mirrors on the inner column, which allow for a second pass of the unabsorbed fraction of the millimetre wave beam. Since the beam path in the plasma is subject to refraction, the beam position on the holographic mirror has to be controlled. Thermocouples built into the mirror surface are used for this purpose. As a protective measure, the tiles of the heat shield on the inner column were modified in order to increase the shielding against unabsorbed millimetre wave power.

  1. Extension of electron cyclotron heating at ASDEX Upgrade with respect to high density operation

    Directory of Open Access Journals (Sweden)

    Schubert Martin

    2017-01-01

    Full Text Available The ASDEX Upgrade electron cyclotron resonance heating operates at 105 GHz and 140 GHz with flexible launching geometry and polarization. In 2016 four Gyrotrons with 10 sec pulse length and output power close to 1 MW per unit were available. The system is presently being extended to eight similar units in total. High heating power and high plasma density operation will be a part of the future ASDEX Upgrade experiment program. For the electron cyclotron resonance heating, an O-2 mode scheme is proposed, which is compatible with the expected high plasma densities. It may, however, suffer from incomplete single-pass absorption. The situation can be improved significantly by installing holographic mirrors on the inner column, which allow for a second pass of the unabsorbed fraction of the millimetre wave beam. Since the beam path in the plasma is subject to refraction, the beam position on the holographic mirror has to be controlled. Thermocouples built into the mirror surface are used for this purpose. As a protective measure, the tiles of the heat shield on the inner column were modified in order to increase the shielding against unabsorbed millimetre wave power.

  2. Enhanced Physicochemical and Biological Properties of Ion-Implanted Titanium Using Electron Cyclotron Resonance Ion Sources

    Directory of Open Access Journals (Sweden)

    Csaba Hegedűs

    2016-01-01

    Full Text Available The surface properties of metallic implants play an important role in their clinical success. Improving upon the inherent shortcomings of Ti implants, such as poor bioactivity, is imperative for achieving clinical use. In this study, we have developed a Ti implant modified with Ca or dual Ca + Si ions on the surface using an electron cyclotron resonance ion source (ECRIS. The physicochemical and biological properties of ion-implanted Ti surfaces were analyzed using various analytical techniques, such as surface analyses, potentiodynamic polarization and cell culture. Experimental results indicated that a rough morphology was observed on the Ti substrate surface modified by ECRIS plasma ions. The in vitro electrochemical measurement results also indicated that the Ca + Si ion-implanted surface had a more beneficial and desired behavior than the pristine Ti substrate. Compared to the pristine Ti substrate, all ion-implanted samples had a lower hemolysis ratio. MG63 cells cultured on the high Ca and dual Ca + Si ion-implanted surfaces revealed significantly greater cell viability in comparison to the pristine Ti substrate. In conclusion, surface modification by electron cyclotron resonance Ca and Si ion sources could be an effective method for Ti implants.

  3. Study of ion beam transport from the SECRAL electron cyclotron resonance ion source at the Institute of Modern Physics.

    Science.gov (United States)

    Cao, Y; Lu, W; Zhang, W H; Sha, S; Yang, Y; Ma, B H; Wang, H; Zhu, Y H; Guo, J W; Fang, X; Lin, S H; Li, X X; Feng, Y C; Li, J Y; Zhao, H Y; Ma, H Y; Zhang, X Z; Guo, X H; Wu, Q; Sun, L T; Zhao, H W; Xie, D Z

    2012-02-01

    Ion beam transport from the Superconducting Electron Cyclotron Resonance ion source with Advanced design in Lanzhou (SECRAL) electron cyclotron resonance ion source was studied at the Institute of Modern Physics during 2010. Particle-in-cell simulations and experimental results have shown that both space charge and magnetic aberrations lead to a larger beam envelope and emittance growth. In the existing SECRAL extraction beam line, it has been shown that raising the solenoid lens magnetic field reduces aberrations in the subsequent dipole and results in lower emittance. Detailed beam emittance measurements are presented in this paper.

  4. Adaptive-array Electron Cyclotron Emission diagnostics using data streaming in a Software Defined Radio system

    Science.gov (United States)

    Idei, H.; Mishra, K.; Yamamoto, M. K.; Hamasaki, M.; Fujisawa, A.; Nagashima, Y.; Hayashi, Y.; Onchi, T.; Hanada, K.; Zushi, H.; the QUEST Team

    2016-04-01

    Measurement of the Electron Cyclotron Emission (ECE) spectrum is one of the most popular electron temperature diagnostics in nuclear fusion plasma research. A 2-dimensional ECE imaging system was developed with an adaptive-array approach. A radio-frequency (RF) heterodyne detection system with Software Defined Radio (SDR) devices and a phased-array receiver antenna was used to measure the phase and amplitude of the ECE wave. The SDR heterodyne system could continuously measure the phase and amplitude with sufficient accuracy and time resolution while the previous digitizer system could only acquire data at specific times. Robust streaming phase measurements for adaptive-arrayed continuous ECE diagnostics were demonstrated using Fast Fourier Transform (FFT) analysis with the SDR system. The emission field pattern was reconstructed using adaptive-array analysis. The reconstructed profiles were discussed using profiles calculated from coherent single-frequency radiation from the phase array antenna.

  5. Production and decay of chlorine ion excited species in an electron cyclotron resonance ion source plasma

    Energy Technology Data Exchange (ETDEWEB)

    Santos, J P; Martins, M C; Parente, F [Centro de Fisica Atomica, CFA, Departamento de Fisica, Faculdade de Ciencias e Tecnologia, FCT, Universidade Nova de Lisboa, 2829-516 Caparica (Portugal); Costa, A M; Marques, J P [Centro de Fisica Atomica, CFA, Departamento de Fisica, Faculdade de Ciencias, FCUL, Universidade de Lisboa, Campo Grande, 1749-016 Lisboa (Portugal); Indelicato, P, E-mail: jps@fct.unl.pt [Laboratoire Kastler Brossel, Ecole Normale Superieure, CNRS, Universite P et M Curie-Paris 6, Case 74, 4 place Jussieu, 75252 Paris Cedex 05 (France)

    2011-06-15

    The most important processes for the creation of chlorine ion excited states from the ground configurations of Cl{sup 10+} to Cl{sup 15+} ions in an electron cyclotron resonance ion source, leading to the emission of K x-ray lines, were studied. Theoretical values for inner-shell excitation and ionization cross-sections, including double KL and triple KLL ionization, transition probabilities and energies for the de-excitation processes, were calculated in the framework of the multi-configuration Dirac-Fock method. With reasonable assumptions about the electron energy distribution, a theoretical K{alpha} x-ray spectrum was obtained, which was then compared with recent experimental data.

  6. Design of a correlation electron cyclotron emission diagnostic for Alcator C-Moda)

    Science.gov (United States)

    Sung, C.; White, A. E.; Irby, J. H.; Leccacorvi, R.; Vieira, R.; Oi, C. Y.; Peebles, W. A.; Nguyen, X.

    2012-10-01

    A correlation electron cyclotron emission (CECE) diagnostic has been installed in Alcator C-Mod. In order to measure electron temperature fluctuations, this diagnostic uses a spectral decorrelation technique. Constraints obtained with nonlinear gyrokinetic simulations guided the design of the optical system and receiver. The CECE diagnostic is designed to measure temperature fluctuations which have kθ ≤ 4.8 cm-1 (kθρs < 0.5) using a well-focused beam pattern. Because the CECE diagnostic is a dedicated turbulence diagnostic, the optical system is also flexible, which allows for various collimating lenses and antenna to be used. The system overview and the demonstration of its operability as designed are presented in this paper.

  7. Electron cyclotron resonance heating by magnetic filter field in a negative hydrogen ion source

    Energy Technology Data Exchange (ETDEWEB)

    Kim, June Young, E-mail: beacoolguy@snu.ac.kr; Cho, Won-Hwi; Dang, Jeong-Jeung; Chung, Kyoung-Jae, E-mail: jkjlsh1@snu.ac.kr; Hwang, Y. S. [Department of Nuclear Engineering, Seoul National University, Seoul 151-742 (Korea, Republic of)

    2016-02-15

    The influence of magnetic filter field on plasma properties in the heating region has been investigated in a planar-type inductively coupled radio-frequency (RF) H{sup −} ion source. Besides filtering high energy electrons near the extraction region, the magnetic filter field is clearly observed to increase the electron temperature in the heating region at low pressure discharge. With increasing the operating pressure, enhancement of electron temperature in the heating region is reduced. The possibility of electron cyclotron resonance (ECR) heating in the heating region due to stray magnetic field generated by a filter magnet located at the extraction region is examined. It is found that ECR heating by RF wave field in the discharge region, where the strength of an axial magnetic field is approximately ∼4.8 G, can effectively heat low energy electrons. Depletion of low energy electrons in the electron energy distribution function measured at the heating region supports the occurrence of ECR heating. The present study suggests that addition of axial magnetic field as small as several G by an external electromagnet or permanent magnets can greatly increase the generation of highly ro-vibrationally excited hydrogen molecules in the heating region, thus improving the performance of H{sup −} ion generation in volume-produced negative hydrogen ion sources.

  8. Electron cyclotron resonance discharge as a source for hydrogen and deuterium ions production

    Energy Technology Data Exchange (ETDEWEB)

    Chacon Velasco, A.J. [Universidad de Pamplona, Pamplona (Colombia); Dougar-Jabon, V.D. [Universidad Industrial de Santander, Bucaramanga (Colombia)

    2004-07-01

    In this report, we describe characteristics of a ring-structure hydrogen plasma heated in electron cyclotron resonance conditions and confined in a mirror magnetic trap and discuss the relative efficiency of secondary electrons and thermo-electrons in negative hydrogen and deuterium ion production. The obtained data and calculations of the balance equations for possible reactions demonstrate that the negative ion production is realized in two stages. First, the hydrogen and deuterium molecules are excited in collisions with the plasma electrons to high-laying Rydberg or vibrational levels in the plasma volume. The second stage leads to the negative ion production through the process of dissociative attachment of low energy electrons. The low energy electrons are originated due to a bombardment of the plasma electrode by ions of one of the driven rings and thermo-emission from heated tungsten filaments. Experiments seem to indicate that the negative ion generation occurs predominantly in the limited volume filled with thermo-electrons. Estimation of the negative ion generation rate shows that the main channel of H{sup -} and D{sup -} ion production involves the process of high Rydberg state excitation. (authors)

  9. Conceptual design studies of the Electron Cyclotron launcher for DEMO reactor

    Science.gov (United States)

    Moro, Alessandro; Bruschi, Alex; Franke, Thomas; Garavaglia, Saul; Granucci, Gustavo; Grossetti, Giovanni; Hizanidis, Kyriakos; Tigelis, Ioannis; Tran, Minh-Quang; Tsironis, Christos

    2017-10-01

    A demonstration fusion power plant (DEMO) producing electricity for the grid at the level of a few hundred megawatts is included in the European Roadmap [1]. The engineering design and R&D for the electron cyclotron (EC), ion cyclotron and neutral beam systems for the DEMO reactor is being performed by Work Package Heating and Current Drive (WPHCD) in the framework of EUROfusion Consortium activities. The EC target power to the plasma is about 50 MW, in which the required power for NTM control and burn control is included. EC launcher conceptual design studies are here presented, showing how the main design drivers of the system have been taken into account (physics requirements, reactor relevant operations, issues related to its integration as in-vessel components). Different options for the antenna are studied in a parameters space including a selection of frequencies, injection angles and launch points to get the best performances for the antenna configuration, using beam tracing calculations to evaluate plasma accessibility and deposited power. This conceptual design studies comes up with the identification of possible limits, constraints and critical issues, essential in the selection process of launcher setup solution.

  10. Conceptual design studies of the Electron Cyclotron launcher for DEMO reactor

    Directory of Open Access Journals (Sweden)

    Moro Alessandro

    2017-01-01

    Full Text Available A demonstration fusion power plant (DEMO producing electricity for the grid at the level of a few hundred megawatts is included in the European Roadmap [1]. The engineering design and R&D for the electron cyclotron (EC, ion cyclotron and neutral beam systems for the DEMO reactor is being performed by Work Package Heating and Current Drive (WPHCD in the framework of EUROfusion Consortium activities. The EC target power to the plasma is about 50 MW, in which the required power for NTM control and burn control is included. EC launcher conceptual design studies are here presented, showing how the main design drivers of the system have been taken into account (physics requirements, reactor relevant operations, issues related to its integration as in-vessel components. Different options for the antenna are studied in a parameters space including a selection of frequencies, injection angles and launch points to get the best performances for the antenna configuration, using beam tracing calculations to evaluate plasma accessibility and deposited power. This conceptual design studies comes up with the identification of possible limits, constraints and critical issues, essential in the selection process of launcher setup solution.

  11. Rapid Loss of Radiation Belt Relativistic Electrons by EMIC Waves

    Science.gov (United States)

    Su, Zhenpeng; Gao, Zhonglei; Zheng, Huinan; Wang, Yuming; Wang, Shui; Spence, H. E.; Reeves, G. D.; Baker, D. N.; Wygant, J. R.

    2017-10-01

    How relativistic electrons are lost is an important question surrounding the complex dynamics of the Earth's outer radiation belt. Radial loss to the magnetopause and local loss to the atmosphere are two main competing paradigms. Here on the basis of the analysis of a radiation belt storm event on 27 February 2014, we present new evidence for the electromagnetic ion cyclotron (EMIC) wave-driven local precipitation loss of relativistic electrons in the heart of the outer radiation belt. During the main phase of this storm, the radial profile of relativistic electron phase space density was quasi-monotonic, qualitatively inconsistent with the prediction of radial loss theory. The local loss at low L shells was required to prevent the development of phase space density peak resulting from the radial loss process at high L shells. The rapid loss of relativistic electrons in the heart of outer radiation belt was observed as a dip structure of the electron flux temporal profile closely related to intense EMIC waves. Our simulations further confirm that the observed EMIC waves within a quite limited longitudinal region were able to reduce the off-equatorially mirroring relativistic electron fluxes by up to 2 orders of magnitude within about 1.5 h.

  12. Design of the ITER upper port electron cyclotron heating and current drive system based on remote steering

    NARCIS (Netherlands)

    M. F. Graswinckel,; van den Berg, M. A.; Bongers, W. A.; Donne, A. J. H.; Goede, A. P. H.; Cardozo, N. L.; Ronden, D. M. S.; Verhoeven, A. G. A.

    2008-01-01

    A design is presented for the electron cyclotron (EC) heating and current drive system of the ITER upper port launchers based on the remote steering (RS) concept. In this concept the millimeter-wave beam is steered by a mirror that is located at the back end of the launcher waveguide. The RS concept

  13. Main-ion temperature and plasma rotation measurements based on scattering of electron cyclotron heating waves in ASDEX Upgrade

    DEFF Research Database (Denmark)

    Pedersen, Morten Stejner; Rasmussen, Jesper; Nielsen, Stefan Kragh

    2017-01-01

    We demonstrate measurements of spectra of O-mode electron cyclotron resonance heating (ECRH) waves scattered collectively from microscopic plasma fluctuations in ASDEX Upgrade discharges with an ITER-like ECRH scenario. The measured spectra are shown to allow determination of the main ion...

  14. Two-chamber configuration of Bio-Nano electron cyclotron resonance ion source for fullerene modification

    Energy Technology Data Exchange (ETDEWEB)

    Uchida, T., E-mail: uchida-t@toyo.jp [Bio-Nano Electronics Research Centre, Toyo University, Kawagoe 350-8585 (Japan); Graduate School of Interdisciplinary New Science, Toyo University, Kawagoe 350-8585 (Japan); Rácz, R.; Biri, S. [Institute for Nuclear Research (Atomki), Hungarian Academy of Sciences, Bem tér 18/C, H-4026 Debrecen (Hungary); Muramatsu, M.; Kitagawa, A. [National Institute of Radiological Sciences (NIRS), Chiba 263-8555 (Japan); Kato, Y. [Graduate School of Engineering, Osaka University, Suita 565-0871 (Japan); Yoshida, Y. [Bio-Nano Electronics Research Centre, Toyo University, Kawagoe 350-8585 (Japan); Faculty of Science and Engineering, Toyo University, Kawagoe 350-8585 (Japan)

    2016-02-15

    We report on the modification of fullerenes with iron and chlorine using two individually controllable plasmas in the Bio-Nano electron cyclotron resonance ion source (ECRIS). One of the plasmas is composed of fullerene and the other one is composed of iron and chlorine. The online ion beam analysis allows one to investigate the rate of the vapor-phase collisional modification process in the ECRIS, while the offline analyses (e.g., liquid chromatography-mass spectrometry) of the materials deposited on the plasma chamber can give information on the surface-type process. Both analytical methods show the presence of modified fullerenes such as fullerene-chlorine, fullerene-iron, and fullerene-chlorine-iron.

  15. First results of the 2.45 GHz Oshima electron cyclotron resonance ion source

    Energy Technology Data Exchange (ETDEWEB)

    Asaji, T., E-mail: asaji@nc-toyama.ac.jp [National Institute of Technology, Toyama College, 13 Hongo, Toyama 939-8630 (Japan); Nakamura, T.; Furuse, M. [National Institute of Technology, Oshima College, 1091-1 Komatsu, Suouoshima, Oshima, Yamaguchi 742-2193 (Japan); Hitobo, T. [Tateyama Machine Co., Ltd., 30 Shimonoban, Toyama 930-1305 (Japan); Uchida, T. [Graduate School of Engineering, Toyo University, 2100 Kujirai, Kawagoe, Saitama 350-8585 (Japan); Muramatsu, M. [National Institute of Radiological Sciences (NIRS), 4-9-1 Anagawa, Inage-ku, Chiba 263-8555 (Japan); Kato, Y. [Graduate School of Engineering, Osaka University, 2-1 Yamada-oka, Suita, Osaka 565-0871 (Japan)

    2016-02-15

    A new electron cyclotron resonance ion source has been constructed at Oshima College with a 2.45 GHz magnetron microwave source and permanent magnets employed as the main components. In addition, a solid-state power amplifier with a frequency range of 2.5–6.0 GHz was installed to study two-frequency plasma heating. Three solenoid coils were set up for adjusting the axial magnetic fields. Argon plasma generation and ion beam production have been conducted during the first year of operation. Ion current densities in the ECR plasma were measured using a biased disk. For 2.45 and 4.65 GHz two-frequency plasma heating, the ion density was approximately 1.5 times higher than that of 2.45 GHz single-frequency heating.

  16. Electron cyclotron resonance plasma reactor for production of carbon stripper foil

    Science.gov (United States)

    Faith Romero, Camille; Kanamori, Keita; Kinsho, Michikazu; Yoshimoto, Masahiro; Wada, Motoi

    2018-01-01

    A graphite antenna for the production of carbon-containing hydrogen plasmas is being developed to prepare impurity-free charge exchange foils for high-energy synchrotrons. Microwave power at 2.45 GHz frequency drives a coaxial structure antenna with a 12-mm-diameter central graphite cylinder and a tapered surrounding cylinder serving as the ground electrode. The antenna was placed in a linear magnetic field to investigate how it performs under an electron cyclotron resonance (ECR) condition. A clear resonance phenomenon was observed in plasma luminosity, microwave power absorption, and microwave power reflection when the induction current used to produce a linear magnetic field was changed. The antenna realized the best microwave coupling to the plasma with the ECR zone formed 5 mm from the end of the center electrode. The antenna realized stable operation for more than 5 h with 100 W input microwave power and with operating hydrogen pressure from 0.5 to 50 Pa.

  17. Two-chamber configuration of Bio-Nano electron cyclotron resonance ion source for fullerene modification.

    Science.gov (United States)

    Uchida, T; Rácz, R; Muramatsu, M; Kato, Y; Kitagawa, A; Biri, S; Yoshida, Y

    2016-02-01

    We report on the modification of fullerenes with iron and chlorine using two individually controllable plasmas in the Bio-Nano electron cyclotron resonance ion source (ECRIS). One of the plasmas is composed of fullerene and the other one is composed of iron and chlorine. The online ion beam analysis allows one to investigate the rate of the vapor-phase collisional modification process in the ECRIS, while the offline analyses (e.g., liquid chromatography-mass spectrometry) of the materials deposited on the plasma chamber can give information on the surface-type process. Both analytical methods show the presence of modified fullerenes such as fullerene-chlorine, fullerene-iron, and fullerene-chlorine-iron.

  18. Beam experiments with the Grenoble test electron cyclotron resonance ion source at iThemba LABS.

    Science.gov (United States)

    Thomae, R; Conradie, J; Fourie, D; Mira, J; Nemulodi, F; Kuechler, D; Toivanen, V

    2016-02-01

    At iThemba Laboratory for Accelerator Based Sciences (iThemba LABS) an electron cyclotron ion source was installed and commissioned. This source is a copy of the Grenoble Test Source (GTS) for the production of highly charged ions. The source is similar to the GTS-LHC at CERN and named GTS2. A collaboration between the Accelerators and Beam Physics Group of CERN and the Accelerator and Engineering Department of iThemba LABS was proposed in which the development of high intensity argon and xenon beams is envisaged. In this paper, we present beam experiments with the GTS2 at iThemba LABS, in which the results of continuous wave and afterglow operation of xenon ion beams with oxygen as supporting gases are presented.

  19. Accessibility condition of wave propagation and multicharged ion production in electron cyclotron resonance ion source plasma.

    Science.gov (United States)

    Kato, Yushi; Yano, Keisuke; Nishiokada, Takuya; Nagaya, Tomoki; Kimura, Daiju; Kumakura, Sho; Imai, Youta; Hagino, Shogo; Otsuka, Takuro; Sato, Fuminobu

    2016-02-01

    A new tandem type source of electron cyclotron resonance (ECR) plasmas has been constructing for producing synthesized ion beams in Osaka University. Magnetic mirror field configuration with octupole magnets can be controlled to various shape of ECR zones, namely, in the 2nd stage plasma to be available by a pair mirror and a supplemental coil. Noteworthy correlations between these magnetic configurations and production of multicharged ions are investigated in detail, as well as their optimum conditions. We have been considering accessibility condition of electromagnetic and electrostatic waves propagating in ECR ion source plasma, and then investigated their correspondence relationships with production of multicharged ions. It has been clarified that there exits efficient configuration of ECR zones for producing multicharged ion beams experimentally, and then has been suggested from detail accessibility conditions on the ECR plasma that new resonance, i.e., upper hybrid resonance, must have occurred.

  20. Capabilities of the ITER Electron Cyclotron Equatorial Launcher for Heating and Current Drive

    Directory of Open Access Journals (Sweden)

    Ramponi G.

    2012-09-01

    Full Text Available The ITER Electron Cyclotron Equatorial Launcher is designed to be one of the heating systems to assist and sustain the development of various ITER plasma scenarios starting with the very first plasma operation. Here the capabilities for Heating and Current Drive of this system are reviewed. In particular, the optimum launching conditions are investigated for two scenarios at burn, comparing toroidal and poloidal steering options. Then, the EC capabilities are investigated for different plasma parameters corresponding to various phases of the ITER plasma discharge, from current ramp-up up to burn, and for a wide range of magnetic field, focusing in particular on the EC potential for heating and for L to H-mode assist. It is found that the EC system can contribute to a wide range of heating scenarios during the ramp-up of the magnetic field, significantly increasing the applicable range as a function of magnetic field.

  1. Stabilization of ion fishbone activities by electron cyclotron resonance heating in a toroidal plasma

    Science.gov (United States)

    Chen, W.; Yu, L. M.; Shi, P. W.; Ma, R.; Ji, X. Q.; Jiang, M.; Zhu, X. L.; Shi, Z. B.; Yu, D. L.; Yuan, B. S.; Li, Y. G.; Yang, Z. C.; Cao, J. Y.; Song, S. D.; Zhong, W. L.; He, H. D.; Dong, J. Q.; Ding, X. T.; Yan, L. W.; Liu, Yi.; Yang, Q. W.; Xu, M.; Duan, X. R.

    2018-01-01

    We report an experimental result on the stabilization of the energetic–ion driven internal kink mode (ion fishbone) by electron cyclotron resonance heating (ECRH), observed for the first time in a toroidal plasma. The mode asserts itself a resistive branch close to the marginal stability point. The resulting fishbone mode depends not only on the injected power but also on the radial deposition location of ECRH, and the instability can be completely suppressed when the injected ECRH power exceeds certain threshold. Analysis by the fishbone dispersion relation, including the resistive effect, suggests that the magnetic Reynolds number plays a key role in the mode stabilization—it weakens the mode growth-rate and enhances the critical energetic–ion beta without changing the energetic–ion population. This ion fishbone stabilization mechanism can be important for future devices such as ITER, which has significant ECRH capability.

  2. Status of charge breeding with electron cyclotron resonance ion sources (invited)

    CERN Document Server

    Lamy, T; Sortais, P; Thuillier, T; 10.1063/1.2149300

    2006-01-01

    Due to the production methods of exotic nuclei, an efficient acceleration of radioactive ion beams needs charge breeding of weakly charged ions. The upgrade of existing isotope separator on-line facilities (TRIUMF-isotope separation and acceleration, CERN-isotope separation on-line detector, etc.) or the development of projects for the acceleration of radioactive ion beams (GANIL-SPIRAL2, MAFF, EURISOL, etc.) requires charge breeders with high efficiency, fast charge breeding time, low background levels, and high intensity acceptance either in continuous or in pulsed mode. The optimization of these parameters is a challenge for the electron cyclotron resonance (ECR) community and is useful to get a better understanding of plasma physics in ECR ion sources (ECRISs). The ECR charge breeding technique has been developed for more than ten years at LPSC (former ISN) Grenoble, typical 1+rightward arrown+ efficiencies are in the 3%-10% range depending on the nature of the incoming beam (metallic, alkaline, and gaseo...

  3. Poloidal rotation driven by electron cyclotron resonance wave in tokamak plasmas

    Directory of Open Access Journals (Sweden)

    Qing Zhou

    2017-10-01

    Full Text Available The poloidal electric filed, which is the drive field of poloidal rotation, has been observed and increases obviously after the injection of electron cyclotron resonance wave in HL-2A experiment, and the amplitude of the poloidal electric field is in the order of 103 V/m. Through theoretical analysis using Stringer rotation model, the observed poloidal electric field is of the same order as the theoretical calculation value. In addition, the magnetic pump damping which would damp the poloidal rotation is calculated numerically and the calculation results show that the closer to the core plasmas, the stronger the magnetic pump damping will be. Meanwhile, according to the value of the calculated magnetic pump damping, the threshold of the poloidal electric field which could overcome magnetic pump damping and drive poloidal rotation in tokamak plasmas is given out. Finally, the poloidal rotation velocity over time at different minor radius is studied theoretically.

  4. Status report on electron cyclotron resonance ion sources at the Heavy Ion Medical Accelerator in Chiba

    CERN Document Server

    Kitagawa, A; Sekiguchi, M; Yamada, S; Jincho, K; Okada, T; Yamamoto, M; Hattori, T G; Biri, S; Baskaran, R; Sakata, T; Sawada, K; Uno, K

    2000-01-01

    The Heavy Ion Medical Accelerator in Chiba at the National Institute of Radiological Sciences (NIRS) is not only dedicated to cancer therapy, it is also utilized with various ion species for basic experiments of biomedical science, physics, chemistry, etc. Two electron cyclotron resonance (ECR) ion sources are installed for production of gaseous ions. One of them, the NIRS-ECR, is a 10 GHz ECR ion source, and is mainly operated to produce C/sup 4+/ ions for daily clinical treatment. This source realizes good reproducibility and reliability and it is easily operated. The other source, the NIRS-HEC, is an 18 GHz ECR ion source that is expected to produce heavier ion species. The output ion currents of the NIRS-ECR and the NIRS-HEC are 430e mu A for C/sup 4+/ and 1.1e mA for Ar/sup 8+/, respectively. (14 refs).

  5. Development of Electron Cyclotron Resonance Ion Source for Synthesis of Endohedral Metallofullerenes

    Science.gov (United States)

    Tanaka, K.; Muramatsu, M.; Uchida, T.; Biri, S.; Asaji, T.; Shima, K.; Hanajiri, T.; Kitagawa, A.; Kato, Y.; Yoshida, Y.

    2008-11-01

    A new electron cyclotron resonance ion source (ECRIS) has been constructed for synthesis of endohedral metallofullerenes. The main purpose of the ion source is to produce new biological and medical materials. The design is based on ECRIS for production of multicharged ion beams with a traditional minimum-B magnetic field. An 8-10 GHz traveling wave tube (TWT) amplifier and a 2.45 GHz magnetron have been applied as microwave sources. Fullerene and metal vapor are introduced with a filament heating micro-oven and an induction heating oven, respectively. In preliminary ion-extraction test, Ar+ is 54 μA. Many broken fullerenes such as C58 and C56 are observed in fullerene ion beams.

  6. Time evolution of bremsstrahlung and ion production of an electron cyclotron resonance ion source

    Energy Technology Data Exchange (ETDEWEB)

    Tarvainen, Ollie [Los Alamos National Laboratory; Ropponen, Tommi [UNIV OF JYVASKYLA; Jones, Peter [UNIV OF JYVASKYLA; Peura, Pauli [UNIV OF JYVASKYLA

    2008-01-01

    Bremsstrahlung radiation measurement is one of the most commonly used plasma diagnostics methods. Most of the bremsstrahlung measurements with electron cyclotron resonance (ECR) ion sources have been performed in continuous operation mode yielding information only on the steady state bremsstrahlung emission. This article describes the results of bremsstrahlung and ion current measurement with the JYFL 14 GHz ECRIS operated in pulsed mode. The experiments reveal information about the bremsstrahlung radiation in plasma conditions before reaching the equilibrium. The time scale of bremsstrahlung production is compared to ion production time scale for different charge states. The bremsstrahlung data is presented with 2 millisecond time intervals as a function of neutral gas pressure and microwave power. Data from hundreds of microwave pulses is combined in order to have a sufficient amount of events at each time step. The relevant plasma physics phenomena during both, the leading and the trailing edge of the RF pulse, are discussed.

  7. Study on the electron-cyclotron-emission diagnostics on JT-60U

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Cheol Kyu [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1996-09-01

    Diagnostic system for electron cyclotron emission(ECE) in JT-60 have been surveyed. At JT-60 there are three different ECE-systems: a Fourier transformed spectroscopy system(FTS), a grating polycromater system(GPS), and a heterodyne radiometer system(HRS). Each of the systems has been examined to understand the instrumental feature with much attention to the sensitivity and the resolution. FTS has been studied with particular interest because of its continuous and wide spectral coverage and reliable characteristics for calibration. Some topics in instrumentation for FTS are discussed to get an insight on the system specifications optimal for tokamak experiments. Finally, experimental results of FTS with black body radiation at liquid-nitrogen temperature are described in connection with the calibration of the light guiding system for ECE from JT-60 plasma. 14 refs. (Author).

  8. Modeling of the influences of multiple modulated electron cyclotron current drive on NTMs in rotating plasma

    Science.gov (United States)

    Chen, Long; Liu, Jinyuan; Duan, Ping; Liu, Guangrui; Bian, Xingyu

    2017-02-01

    In this work, physical models of neoclassical tearing modes (NTMs) including bootstrap current and multiple modulated electron cyclotron current drive model are applied. Based on the specific physical problems during the suppression of NTMs by driven current, this work compares the efficiency of continuous and modulated driven currents, and simulates the physical processes of multiple modulated driven currents on suppressing rotating magnetic island. It is found that when island rotates along the poloidal direction, the suppression ability of continuous driven current can be massively reduced due to current deposition outside the island separatrix and reverse deposition direction at the X point, which can be avoided by current drive modulation. Multiple current drive has a better suppressing effect than single current drive. This work gives realistic numerical simulations by optimizing the model and parameters based on the experiments, which could provide references for successful suppression of NTMs in future advanced tokamak such as international thermonuclear experimental reactor.

  9. Data acquisition and processing system of the electron cyclotron emission imaging system of the KSTAR tokamak.

    Science.gov (United States)

    Kim, J B; Lee, W; Yun, G S; Park, H K; Domier, C W; Luhmann, N C

    2010-10-01

    A new innovative electron cyclotron emission imaging (ECEI) diagnostic system for the Korean Superconducting Tokamak Advanced Research (KSTAR) produces a large amount of data. The design of the data acquisition and processing system of the ECEI diagnostic system should consider covering the large data production and flow. The system design is based on the layered structure scalable to the future extension to accommodate increasing data demands. Software architecture that allows a web-based monitoring of the operation status, remote experiment, and data analysis is discussed. The operating software will help machine operators and users validate the acquired data promptly, prepare next discharge, and enhance the experiment performance and data analysis in a distributed environment.

  10. New compact and efficient local oscillator optic system for the KSTAR electron cyclotron emission imaging system

    Energy Technology Data Exchange (ETDEWEB)

    Nam, Y. B., E-mail: southub@postech.ac.kr; Yun, G. S. [Department of Physics, Pohang University of Science and Technology, Pohang 37673 (Korea, Republic of); Lee, D. J.; Lee, J.; Lee, W. [Ulsan National Institute of Science and Technology, Ulsan 44919 (Korea, Republic of); Kim, C. [Pennsylvania State University, Old Main, State College, Pennsylvania 16801 (United States); Park, H. K. [Ulsan National Institute of Science and Technology, Ulsan 44919 (Korea, Republic of); National Fusion Research Institute, Daejeon 34133 (Korea, Republic of)

    2016-11-15

    Electron cyclotron emission imaging (ECEI) diagnostic on Korean Superconducting Tokamak Advanced Research utilizes quasi-optical heterodyne-detection method to measure 2D (vertical and radial) T{sub e} fluctuations from two toroidally separated poloidal cross section of the plasma. A cylindrical lens local oscillator (LO) optics with optical path length (OPL) 2–2.5 m has been used in the current ECEI system to couple the LO source to the 24 vertically aligned array of ECE detectors. For efficient and compact LO optics employing the Powell lens is proposed so that the OPL of the LO source is significantly reduced from ∼2.0 m to 0.4 m with new optics. The coupling efficiency of the LO source is expected to be improved especially at the edge channels. Results from the optical simulation together with the laboratory test of the prototype optics will be discussed in this paper.

  11. Innovations in optical coupling of the KSTAR electron cyclotron emission imaging diagnostic.

    Science.gov (United States)

    Liang, T; Tobias, B; Kong, X; Domier, C W; Luhmann, N C; Lee, W; Yun, G S; Park, H K

    2010-10-01

    The installation of a new electron cyclotron emission imaging diagnostic for the Korea Superconducting Tokamak Advanced Research (KSTAR) is underway, making use of a unique optical port cassette design, which allows placement of refractive elements inside the cryostat region without adverse effects. The result is unprecedented window access for the implementation of a state of the art imaging diagnostic. A dual-array optical design has been developed, capable of simultaneously imaging the high and low field sides of the plasma with independent features of focal plane translation, vertical zoom, and radial channel spacing. The number of translating optics has been minimized by making use of a zoom lens triplet and parabolic plasma facing lens for maximum channel uniformity over a continuous vertical zoom range of 3:1. The simulated performance of this design is presented along with preliminary laboratory characterization data.

  12. Beam experiments with the Grenoble test electron cyclotron resonance ion source at iThemba LABS

    Energy Technology Data Exchange (ETDEWEB)

    Thomae, R., E-mail: rthomae@tlabs.ac.za; Conradie, J.; Fourie, D.; Mira, J.; Nemulodi, F. [iThemba LABS, P.O. Box 722, Somerset West 7130 (South Africa); Kuechler, D.; Toivanen, V. [CERN, BE/ABP/HSL, 1211 Geneva 23 (Switzerland)

    2016-02-15

    At iThemba Laboratory for Accelerator Based Sciences (iThemba LABS) an electron cyclotron ion source was installed and commissioned. This source is a copy of the Grenoble Test Source (GTS) for the production of highly charged ions. The source is similar to the GTS-LHC at CERN and named GTS2. A collaboration between the Accelerators and Beam Physics Group of CERN and the Accelerator and Engineering Department of iThemba LABS was proposed in which the development of high intensity argon and xenon beams is envisaged. In this paper, we present beam experiments with the GTS2 at iThemba LABS, in which the results of continuous wave and afterglow operation of xenon ion beams with oxygen as supporting gases are presented.

  13. Trap density of GeNx/Ge interface fabricated by electron-cyclotron-resonance plasma nitridation

    Science.gov (United States)

    Fukuda, Yukio; Otani, Yohei; Toyota, Hiroshi; Ono, Toshiro

    2011-07-01

    We have investigated GeNx/Ge interface properties using Si3N4(7 nm)/GeNx(2 nm)/Ge metal-insulator-semiconductor structures fabricated by the plasma nitridation of Ge substrates using an electron-cyclotron-resonance-generated nitrogen plasma. The interface trap density (Dit) measured by the conductance method is found to be distributed symmetrically in the Ge band gap with a minimum Dit value lower than 3 × 1011 cm-2eV-1 near the midgap. This result may lead to the development of processes for the fabrication of p- and n-Ge Schottky-barrier (SB) source/drain metal-insulator-semiconductor field-effect transistors using chemically and thermally robust GeNx dielectrics as interlayers for SB source/drain contacts and high-κ gate dielectrics.

  14. Developing laser ablation in an electron cyclotron resonance ion source for actinide detection with AMS

    Energy Technology Data Exchange (ETDEWEB)

    Bauder, W. [Argonne National Laboratory, Physics Division, 9600 S. Cass Ave, Lemont, IL 60439 (United States); University of Notre Dame, Nuclear Science Laboratory, 124 Nieuwland Science Hall, Notre Dame, IN 46556 (United States); Pardo, R.C.; Kondev, F.G.; Kondrashev, S.; Nair, C.; Nusair, O. [Argonne National Laboratory, Physics Division, 9600 S. Cass Ave, Lemont, IL 60439 (United States); Palchan, T. [Hebrew University, Racah Institute of Physics, Jerusalem 91904 (Israel); Scott, R.; Seweryniak, D.; Vondrasek, R. [Argonne National Laboratory, Physics Division, 9600 S. Cass Ave, Lemont, IL 60439 (United States); Collon, P. [University of Notre Dame, Nuclear Science Laboratory, 124 Nieuwland Science Hall, Notre Dame, IN 46556 (United States); Paul, M. [Hebrew University, Racah Institute of Physics, Jerusalem 91904 (Israel)

    2015-10-15

    A laser ablation material injection system has been developed at the ATLAS electron cyclotron resonance (ECR) ion source for use in accelerator mass spectrometry experiments. Beam production with laser ablation initially suffered from instabilities due to fluctuations in laser energy and cratering on the sample surface by the laser. However, these instabilities were rectified by applying feedback correction for the laser energy and rastering the laser across the sample surface. An initial experiment successfully produced and accelerated low intensity actinide beams with up to 1000 counts per second. With continued development, laser ablation shows promise as an alternative material injection scheme for ECR ion sources and may help substantially reduce cross talk in the source.

  15. Intense highly charged ion beam production and operation with a superconducting electron cyclotron resonance ion source

    Directory of Open Access Journals (Sweden)

    H. W. Zhao

    2017-09-01

    Full Text Available The superconducting electron cyclotron resonance ion source with advanced design in Lanzhou (SECRAL is a superconducting-magnet-based electron cyclotron resonance ion source (ECRIS for the production of intense highly charged heavy ion beams. It is one of the best performing ECRISs worldwide and the first superconducting ECRIS built with an innovative magnet to generate a high strength minimum-B field for operation with heating microwaves up to 24–28 GHz. Since its commissioning in 2005, SECRAL has so far produced a good number of continuous wave intensity records of highly charged ion beams, in which recently the beam intensities of ^{40}Ar^{12+} and ^{129}Xe^{26+} have, for the first time, exceeded 1 emA produced by an ion source. Routine operations commenced in 2007 with the Heavy Ion accelerator Research Facility in Lanzhou (HIRFL, China. Up to June 2017, SECRAL has been providing more than 28,000 hours of highly charged heavy ion beams to the accelerator demonstrating its great capability and reliability. The great achievement of SECRAL is accumulation of numerous technical advancements, such as an innovative magnetic system and an efficient double-frequency (24+18  GHz heating with improved plasma stability. This article reviews the development of SECRAL and production of intense highly charged ion beams by SECRAL focusing on its unique magnet design, source commissioning, performance studies and enhancements, beam quality and long-term operation. SECRAL development and its performance studies representatively reflect the achievements and status of the present ECR ion source, as well as the ECRIS impacts on HIRFL.

  16. Intense highly charged ion beam production and operation with a superconducting electron cyclotron resonance ion source

    Science.gov (United States)

    Zhao, H. W.; Sun, L. T.; Guo, J. W.; Lu, W.; Xie, D. Z.; Hitz, D.; Zhang, X. Z.; Yang, Y.

    2017-09-01

    The superconducting electron cyclotron resonance ion source with advanced design in Lanzhou (SECRAL) is a superconducting-magnet-based electron cyclotron resonance ion source (ECRIS) for the production of intense highly charged heavy ion beams. It is one of the best performing ECRISs worldwide and the first superconducting ECRIS built with an innovative magnet to generate a high strength minimum-B field for operation with heating microwaves up to 24-28 GHz. Since its commissioning in 2005, SECRAL has so far produced a good number of continuous wave intensity records of highly charged ion beams, in which recently the beam intensities of 40Ar+ and 129Xe26+ have, for the first time, exceeded 1 emA produced by an ion source. Routine operations commenced in 2007 with the Heavy Ion accelerator Research Facility in Lanzhou (HIRFL), China. Up to June 2017, SECRAL has been providing more than 28,000 hours of highly charged heavy ion beams to the accelerator demonstrating its great capability and reliability. The great achievement of SECRAL is accumulation of numerous technical advancements, such as an innovative magnetic system and an efficient double-frequency (24 +18 GHz ) heating with improved plasma stability. This article reviews the development of SECRAL and production of intense highly charged ion beams by SECRAL focusing on its unique magnet design, source commissioning, performance studies and enhancements, beam quality and long-term operation. SECRAL development and its performance studies representatively reflect the achievements and status of the present ECR ion source, as well as the ECRIS impacts on HIRFL.

  17. Whistler-cyclotron spontaneous fluctuations. A proxy to identify thermal and non-thermal electrons?

    Science.gov (United States)

    Moya, P. S.; López, R. A.; Navarro, R.; Vinas, A. F.; Munoz, V.; Araneda, J. A.; Valdivia, J. A.

    2016-12-01

    Observed electron velocity distributions in the space plasmas exhibit a variety of non-thermal features which deviate from thermal equilibrium, in the form of temperature anisotropies, suprathermal tails, and field aligned beams. The state close to thermal equilibrium and its departure from it provides a source for spontaneous emissions of electromagnetic fluctuations. For example, the whistler cyclotron waves at electron scales. Here we present a comparative analysis of these fluctuations based upon anisotropic plasma modeled with thermal and non-thermal particle distributions. The analysis presented here considers the second-order theory of fluctuations and the dispersion relation of weakly transverse fluctuations, with wave vectors parallel to the uniform background magnetic field, in a finite temperature isotropic magnetized electron-proton plasma modeled with bi-Maxwellian and kappa-like distributions. Dispersion analysis and stability thresholds are derived for these non-thermal distributions and compared with similar results obtained from PIC simulations using plasma and field parameters relevant to space nearly collisionless environments. Our results indicate that there is a strong dependence between the shape of the velocity distribution function and the spontaneous magnetic fluctuations wave spectrum. This feature may be used proxy to identify the nature of electron populations in space plasmas when high resolution particle instruments are not available.

  18. Advanced electron cyclotron heating and current drive experiments on the stellarator Wendelstein 7-X

    Directory of Open Access Journals (Sweden)

    Stange Torsten

    2017-01-01

    Full Text Available During the first operational phase (OP 1.1 of Wendelstein 7-X (W7-X electron cyclotron resonance heating (ECRH was the exclusive heating method and provided plasma start-up, wall conditioning, heating and current drive. Six gyrotrons were commissioned for OP1.1 and used in parallel for plasma operation with a power of up to 4.3 MW. During standard X2-heating the spatially localized power deposition with high power density allowed controlling the radial profiles of the electron temperature and the rotational transform. Even though W7-X was not fully equipped with first wall tiles and operated with a graphite limiter instead of a divertor, electron densities of n e > 3·1019 m-3 could be achieved at electron temperatures of several keV and ion temperatures above 2 keV. These plasma parameters allowed the first demonstration of a multipath O2-heating scenario, which is envisaged for safe operation near the X-cutoff-density of 1.2·1020 m-3 after full commissioning of the ECRH system in the next operation phase OP1.2.

  19. Electron cyclotron maser emission in coronal arches and solar radio type V bursts

    Energy Technology Data Exchange (ETDEWEB)

    Tang, J. F. [Xinjiang Astronomical Observatory, Chinese Academy of Sciences, 150 Science 1-Street, Urumqi, Xinjiang 830011 (China); Wu, D. J. [Purple Mountain Observatory, CAS, Nanjing 210008 (China); Tan, C. M., E-mail: jftang@xao.ac.cn [Key Laboratory of Solar Activity, National Astronomical Observatories, Chinese Academy of Sciences, Beijing 100012 (China)

    2013-12-10

    Solar radio type V bursts were classified as a special spectral class based on their moderately long duration, wide bandwidth, and sense of polarization opposite of associated type III bursts. However, type V bursts are also closely related to the preceding type III bursts. They have an approximately equal source height and the same dispersion of position with frequency. Electron cyclotron maser (ECM) instability driven by beam electrons has been used to explain type III bursts in recent years. We propose ECM emission as the physical process of type V solar radio bursts. According to the observed properties of type V and III bursts, we propose that energetic electrons in excited type V continuum are trapped in coronal loops, which are adjacent to the open field lines traced by type III electrons. With the proposed magnetic field configuration and the ECM emission mechanism, the observed properties of type V bursts, such as long duration, wide bandwidth, and opposite sense of polarization can be reasonably explained by our model.

  20. Advanced electron cyclotron heating and current drive experiments on the stellarator Wendelstein 7-X

    Science.gov (United States)

    Stange, Torsten; Laqua, Heinrich Peter; Beurskens, Marc; Bosch, Hans-Stephan; Bozhenkov, Sergey; Brakel, Rudolf; Braune, Harald; Brunner, Kai Jakob; Cappa, Alvaro; Dinklage, Andreas; Erckmann, Volker; Fuchert, Golo; Gantenbein, Gerd; Gellert, Florian; Grulke, Olaf; Hartmann, Dirk; Hirsch, Matthias; Höfel, Udo; Kasparek, Walter; Knauer, Jens; Langenberg, Andreas; Marsen, Stefan; Marushchenko, Nikolai; Moseev, Dmitry; Pablant, Novomir; Pasch, Ekkehard; Rahbarnia, Kian; Mora, Humberto Trimino; Tsujimura, Toru; Turkin, Yuriy; Wauters, Tom; Wolf, Robert

    2017-10-01

    During the first operational phase (OP 1.1) of Wendelstein 7-X (W7-X) electron cyclotron resonance heating (ECRH) was the exclusive heating method and provided plasma start-up, wall conditioning, heating and current drive. Six gyrotrons were commissioned for OP1.1 and used in parallel for plasma operation with a power of up to 4.3 MW. During standard X2-heating the spatially localized power deposition with high power density allowed controlling the radial profiles of the electron temperature and the rotational transform. Even though W7-X was not fully equipped with first wall tiles and operated with a graphite limiter instead of a divertor, electron densities of n e > 3·1019 m-3 could be achieved at electron temperatures of several keV and ion temperatures above 2 keV. These plasma parameters allowed the first demonstration of a multipath O2-heating scenario, which is envisaged for safe operation near the X-cutoff-density of 1.2·1020 m-3 after full commissioning of the ECRH system in the next operation phase OP1.2.

  1. Stochasticity of the energy absorption in the electron cyclotron resonance; Estocasticidad de la absorcion de energia en la resonancia electron-ciclotronica

    Energy Technology Data Exchange (ETDEWEB)

    Gutierrez T, C. [Departamento de Fisica, ININ, A.P. 18-1027, 11801 Mexico D.F. (Mexico); Hernandez A, O

    1998-07-01

    The energy absorption mechanism in cyclotron resonance of the electrons is a present problem, since it could be considered from the stochastic point of view or this related with a non-homogeneous but periodical of plasma spatial structure. In this work using the Bogoliubov average method for a multi periodical system in presence of resonances, the drift equations were obtained in presence of a RF field for the case of electron cyclotron resonance until first order terms with respect to inverse of its cyclotron frequency. The absorbed energy equation is obtained on part of electrons in a simple model and by drift method. It is showed the stochastic character of the energy absorption. (Author)

  2. Electron cyclotron maser instability (ECMI in strong magnetic guide field reconnection

    Directory of Open Access Journals (Sweden)

    R. A. Treumann

    2017-08-01

    Full Text Available The ECMI model of electromagnetic radiation from electron holes is shown to be applicable to spontaneous magnetic reconnection. We apply it to reconnection in strong current-aligned magnetic guide fields. Such guide fields participate only passively in reconnection, which occurs in the antiparallel components to both sides of the guide-field-aligned current sheets with current carried by kinetic Alfvén waves. Reconnection generates long (the order of hundreds of electron inertial scales electron exhaust regions at the reconnection site X point, which are extended perpendicular to the current and the guide fields. Exhausts contain a strongly density-depleted hot electron component and have properties similar to electron holes. Exhaust electron momentum space distributions are highly deformed, exhibiting steep gradients transverse to both the reconnecting and guide fields. Such properties suggest application of the ECMI mechanism with the fundamental ECMI X-mode emission beneath the nonrelativistic guide field cyclotron frequency in localized source regions. An outline of the mechanism and its prospects is given. Potential applications are the kilometric radiation (AKR in auroral physics, solar radio emissions during flares, planetary emissions and astrophysical scenarios (radiation from stars and compact objects involving the presence of strong magnetic fields and field-aligned currents. Drift of the exhausts along the guide field maps the local field and plasma properties. Escape of radiation from the exhaust and radiation source region still poses a problem. The mechanism can be studied in 2-D particle simulations of strong guide field reconnection which favours 2-D, mapping the deformation of the electron distribution perpendicular to the guide field, and using it in the numerical calculation of the ECMI growth rate. The mechanism suggests also that reconnection in general may become a source of the ECMI with or without guide fields. This is

  3. Evidence of local power deposition and electron heating by a standing electromagnetic wave in electron-cyclotron-resonance plasma.

    Science.gov (United States)

    Durocher-Jean, A; Stafford, L; Dap, S; Makasheva, K; Clergereaux, R

    2014-09-01

    Microwave plasmas excited at electron-cyclotron resonance were studied in the 0.5-15 mTorr pressure range. In contrast with low-limit pressure conditions where the plasma emission highlights a fairly homogeneous spatial structure, a periodic spatial modulation (period ∼6.2 cm) appeared as pressure increased. This feature is ascribed to a local power deposition (related to the electron density) due to the presence of a standing electromagnetic wave created by the feed electromagnetic field (2.45 GHz) in the cavity formed by the reactor walls. Analysis of the electron energy probability function by Langmuir probe and optical emission spectroscopy further revealed the presence of a high-energy tail that showed strong periodic spatial modulation at higher pressure. The spatial evolution of the electron density and of the characteristic temperature of these high-energy electrons coincides with the nodes (maximum) and antinodes (minimum) of the standing wave. These spatially-modulated power deposition and electron heating mechanisms are then discussed.

  4. Observation of free electron cyclotron resonance in NaAlSi3O8 feldspar: Direct determination of the effective electron mass

    DEFF Research Database (Denmark)

    Poolton, N.R.J.; Nicholis, J.E.; Bøtter-Jensen, L.

    2001-01-01

    We report the first observation of cyclotron resonances in alkali feldspars, using highly sensitive optical detection methods. In Na-feldspar (NaAlSi3O8). a near isotropic effective electron mass value of m(c)(*) = 0.79m, has been determined. The significance of this measurement in terms of the o......We report the first observation of cyclotron resonances in alkali feldspars, using highly sensitive optical detection methods. In Na-feldspar (NaAlSi3O8). a near isotropic effective electron mass value of m(c)(*) = 0.79m, has been determined. The significance of this measurement in terms...

  5. Discovery of electron cyclotron MASER emission from the magnetic Bp star HD 133880 with the Giant Metrewave Radio Telescope

    Science.gov (United States)

    Das, Barnali; Chandra, Poonam; Wade, Gregg A.

    2018-02-01

    We report the discovery of coherent radio emission from the young, rapidly rotating magnetic Bp star HD 133880 at a frequency of 610 MHz with the Giant Metrewave Radio Telescope (GMRT). This is only the second magnetic star in which coherent radio emission has been detected. In our observations of HD 133880 covering the full rotational cycle of the star (except for a phase window 0.17-0.24), we witness an abrupt order-of-magnitude flux enhancement along with ≈100 per cent right circular polarization. We attribute this phenomenon to coherent electron cyclotron MASER emission. We attribute the lack of left circularly polarized emission to the asymmetric topology of the star's magnetic field. The phase of enhancement, 0.73, differs from the previously reported phase of enhancement, 0.16, (at 610 MHz)by one-half cycle. However, no flux enhancement is found at phase 0.16 in our data, which could be due to an unstable or drifting emission region, or a consequence of the reported changes of the star's rotational period. Either of these factors could have shifted the enhancement to the above-mentioned phase window not sampled by our observations.

  6. Effect of electron-electron interaction on cyclotron resonance in high-mobility InAs/AlSb quantum wells

    Energy Technology Data Exchange (ETDEWEB)

    Krishtopenko, S. S., E-mail: sergey.krishtopenko@mail.ru; Gavrilenko, V. I. [Institute for Physics of Microstructures, Russian Academy of Sciences, 603950 Nizhny Novgorod, GSP-105 (Russian Federation); Lobachevsky State University, 23 Prospekt Gagarina, 603950 Nizhny Novgorod (Russian Federation); Ikonnikov, A. V. [Institute for Physics of Microstructures, Russian Academy of Sciences, 603950 Nizhny Novgorod, GSP-105 (Russian Federation); Orlita, M. [Laboratoire National des Champs Magnétiques Intenses (LNCMI-G), CNRS, 25 rue des Martyrs, B.P. 166, 38042 Grenoble (France); Sadofyev, Yu. G. [P.N. Lebedev Physical Institute, Russian Academy of Sciences, Moscow 119991, GSP-1, 53 Leninskiy Prospect (Russian Federation); Goiran, M. [Laboratoire National des Champs Magnétiques Intenses (LNCMI-T), CNRS, 143 Avenue de Rangueil, 31400 Toulouse (France); Teppe, F.; Knap, W. [Laboratoire Charles Coulomb (L2C), UMR CNRS 5221, GIS-TERALAB, Universite Montpellier II, 34095 Montpellier (France)

    2015-03-21

    We report observation of electron-electron (e-e) interaction effect on cyclotron resonance (CR) in InAs/AlSb quantum well heterostructures. High mobility values allow us to observe strongly pronounced triple splitting of CR line at noninteger filling factors of Landau levels ν. At magnetic fields, corresponding to ν > 4, experimental values of CR energies are in good agreement with single-electron calculations on the basis of eight-band k ⋅ p Hamiltonian. In the range of filling factors 3 < ν < 4 pronounced, splitting of CR line, exceeding significantly the difference in single-electron CR energies, is discovered. The strength of the splitting increases when occupation of the partially filled Landau level tends to a half, being in qualitative agreement with previous prediction by MacDonald and Kallin [Phys. Rev. B 40, 5795 (1989)]. We demonstrate that such behaviour of CR modes can be quantitatively described if one takes into account both electron correlations and the mixing between conduction and valence bands in the calculations of matrix elements of e-e interaction.

  7. The effect of density fluctuations on electron cyclotron beam broadening and implications for ITER

    Science.gov (United States)

    Snicker, A.; Poli, E.; Maj, O.; Guidi, L.; Köhn, A.; Weber, H.; Conway, G.; Henderson, M.; Saibene, G.

    2018-01-01

    We present state-of-the-art computations of propagation and absorption of electron cyclotron waves, retaining the effects of scattering due to electron density fluctuations. In ITER, injected microwaves are foreseen to suppress neoclassical tearing modes (NTMs) by driving current at the q=2 and q=3/2 resonant surfaces. Scattering of the beam can spoil the good localization of the absorption and thus impair NTM control capabilities. A novel tool, the WKBeam code, has been employed here in order to investigate this issue. The code is a Monte Carlo solver for the wave kinetic equation and retains diffraction, full axisymmetric tokamak geometry, determination of the absorption profile and an integral form of the scattering operator which describes the effects of turbulent density fluctuations within the limits of the Born scattering approximation. The approach has been benchmarked against the paraxial WKB code TORBEAM and the full-wave code IPF-FDMC. In particular, the Born approximation is found to be valid for ITER parameters. In this paper, we show that the radiative transport of EC beams due to wave scattering in ITER is diffusive unlike in present experiments, thus causing up to a factor of 2–4 broadening in the absorption profile. However, the broadening depends strongly on the turbulence model assumed for the density fluctuations, which still has large uncertainties.

  8. Design of the 2D electron cyclotron emission imaging instrument for the J-TEXT tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Pan, X. M.; Yang, Z. J., E-mail: yangzj@hust.edu.cn; Ma, X. D.; Ruan, B. W.; Zhuang, G. [State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, Wuhan, Hubei 430074 (China); Zhu, Y. L. [School of Physics, University of Science and Technology of China, Anhui 230026 (China); Luhmann, N. C.; Domier, C. W. [Davis Millimeter Wave Research Center, University of California, Davis, California 95616 (United States)

    2016-11-15

    A new 2D Electron Cyclotron Emission Imaging (ECEI) diagnostic is being developed for the J-TEXT tokamak. It will provide the 2D electron temperature information with high spatial, temporal, and temperature resolution. The new ECEI instrument is being designed to support fundamental physics investigations on J-TEXT including MHD, disruption prediction, and energy transport. The diagnostic contains two dual dipole antenna arrays corresponding to F band (90-140 GHz) and W band (75-110 GHz), respectively, and comprises a total of 256 channels. The system can observe the same magnetic surface at both the high field side and low field side simultaneously. An advanced optical system has been designed which permits the two arrays to focus on a wide continuous region or two radially separate regions with high imaging spatial resolution. It also incorporates excellent field curvature correction with field curvature adjustment lenses. An overview of the diagnostic and the technical progress including the new remote control technique are presented.

  9. Electron cyclotron emission radiometer upgrade on the J-TEXT tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Z. J.; Pan, X. M., E-mail: panxiaoming@hust.edu.cn; Ma, X. D.; Ruan, B. W.; Zhou, R. B.; Zhang, C. [State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, Wuhan, Hubei 430074 (China)

    2016-11-15

    To meet experimental requirements, the J-TEXT electron cyclotron emission (ECE) diagnostic is being upgraded. The front end antenna and transmission line have been modified and a new 8-channel W-band detecting unit has been developed. The improved ECE system will extend the frequency range from 94.5-124.5 GHz to 80.5-124.5 GHz. This will enable the system to cover the most plasma in the radius direction for B{sub T} = 1.8–2.2 T, and it even can cover almost the whole plasma range ρ = − 0.8–0.9 (minus means the high field side) at B{sub T} = 1.8 T. A new auxiliary channel bank with 8 narrow band, tunable yttrium iron garnet filters is planned to add to the ECE system. Due to observations along a major radius, perpendicular to B{sub T}, and relatively low electron temperature, Doppler and relativistic broadening are minimal and thus high spatial resolution measurements can be made at variable locations with these tunable channels.

  10. Bounce Resonance Scattering of Radiation Belt Electrons by Low-Frequency Hiss: Comparison With Cyclotron and Landau Resonances

    Science.gov (United States)

    Cao, Xing; Ni, Binbin; Summers, Danny; Zou, Zhengyang; Fu, Song; Zhang, Wenxun

    2017-10-01

    Bounce resonant interactions with magnetospheric waves have been proposed as an important contributing mechanism for scattering near-equatorially mirroring electrons by violating the second adiabatic invariant associated with the electron bounce motion along a geomagnetic field line. This study demonstrates that low-frequency plasmaspheric hiss with significant wave power below 100 Hz can bounce resonate efficiently with radiation belt electrons. By performing quantitative calculations of pitch angle scattering rates, we show that low-frequency hiss-induced bounce resonant scattering of electrons has a strong dependence on equatorial pitch angle αeq. For electrons with αeq close to 90°, the timescale associated with bounce resonance scattering can be comparable to or even less than 1 h. Cyclotron and Landau resonant interactions between low-frequency hiss and electrons are also investigated for comparisons. It is found that while the bounce and Landau resonances are responsible for the diffusive transport of near-equatorially mirroring electrons to lower αeq, pitch angle scattering by cyclotron resonance could take over to further diffuse electrons into the atmosphere. Bounce resonance provides a more efficient pitch angle scattering mechanism of relativistic (≥1 MeV) electrons than Landau resonance due to the stronger scattering rates and broader resonance coverage of αeq, thereby demonstrating that bounce resonance scattering by low-frequency hiss can contribute importantly to the evolution of the electron pitch angle distribution and the loss of radiation belt electrons.

  11. New development of advanced superconducting electron cyclotron resonance ion source SECRAL (invited).

    Science.gov (United States)

    Zhao, H W; Sun, L T; Lu, W; Zhang, X Z; Guo, X H; Cao, Y; Zhao, H Y; Feng, Y C; Li, J Y; Ma, H Y; Shang, Y; Ma, B H; Wang, H; Li, X X; Xie, D Z

    2010-02-01

    Superconducting electron cyclotron resonance ion source with advance design in Lanzhou (SECRAL) is an 18-28 GHz fully superconducting electron cyclotron resonance (ECR) ion source dedicated for highly charged heavy ion beam production. SECRAL, with an innovative superconducting magnet structure of solenoid-inside-sextupole and at lower frequency and lower rf power operation, may open a new way for developing compact and reliable high performance superconducting ECR ion source. One of the recent highlights achieved at SECRAL is that some new record beam currents for very high charge states were produced by 18 GHz or 18+14.5 GHz double frequency heating, such as 1 e microA of (129)Xe(43+), 22 e microA of (209)Bi(41+), and 1.5 e microA of (209)Bi(50+). To further enhance the performance of SECRAL, a 24 GHz/7 kW gyrotron microwave generator was installed and SECRAL was tested at 24 GHz. Some promising and exciting results at 24 GHz with new record highly charged ion beam intensities were produced, such as 455 e microA of (129)Xe(27+) and 152 e microA of (129)Xe(30+), although the commissioning time was limited within 3-4 weeks and rf power only 3-4 kW. Bremsstrahlung measurements at 24 GHz show that x-ray is much stronger with higher rf frequency, higher rf power. and higher minimum mirror magnetic field (minimum B). Preliminary emittance measurements indicate that SECRAL emittance at 24 GHz is slightly higher that at 18 GHz. SECRAL has been put into routine operation at 18 GHz for heavy ion research facility in Lanzhou (HIRFL) accelerator complex since May 2007. The total operation beam time from SECRAL for HIRFL accelerator has been more than 2000 h, and (129)Xe(27+), (78)Kr(19+), (209)Bi(31+), and (58)Ni(19+) beams were delivered. All of these new developments, the latest results, and long-term operation for the accelerator have again demonstrated that SECRAL is one of the best in the performance of ECR ion source for highly charged heavy ion beam production

  12. A proposal for a novel H ion source based on electron cyclotron resonance heating and surface ionization

    Energy Technology Data Exchange (ETDEWEB)

    Tarvainen, Ollie A [Los Alamos National Laboratory; Kurennoy, Sergey [Los Alamos National Laboratory

    2008-01-01

    A design for a novel H{sup -} ion source based on electron cyclotron resonance plasma heating and surface ionization is presented. The plasma chamber of the source is an rf-cavity designed for TE{sub 111} eigenmode at 2.45 GHz. The desired mode is excited with a loop antenna. The ionization process takes place on a cesiated surface of a biased converter electrode. The H{sup -} ion beam is further 'self-extracted' through the plasma region. The magnetic field of the source is optimized for plasma generation by electron cyclotron resonance heating, and beam extraction. The design features of the source are discussed in detail and the attainable H{sup -} ion current, beam emittance and duty factor of the novel source are estimated.

  13. A quasi-optical electron cyclotron maser for fusion reactor heating

    Energy Technology Data Exchange (ETDEWEB)

    Morse, E.C.

    1990-01-01

    High power microwave and millimeter sources, such as the quasi-optical electron cyclotron maser (QOECM) are important in fusion research as well as in high-energy physics and in other applications. The interaction between the electromagnetic modes of a Fabry-Perot resonator and an electron beam gyrating through a magnetic field has been studied for both the cases of beams parallel and perpendicular to the resonator. The parallel case was theoretically first studied by Kurin for forward and backward wave interaction, and experimentally by Komlev and Kurin. Kreischer and Temkin reviewed the general case of the linear small signal interaction parallel and perpendicular to the resonator. Sprangle, et al discussed the perpendicular case in a self-consistent linear and nonlinear theoretical study using the Gaussian transverse profile of an open resonator with a single longitudinal mode. Experimental verification of the devices operation was first mentioned in work at the Naval Research Laboratory. Theoretical studies using a time-dependent analysis of a large number of longitudinal modes with similar transverse mode profiles have demonstrated that single longitudinal-mode operation can be achieved at equilibrium and that performance can be enhanced by prebunching the electron beam and tapering the magnetic field. The use of output coupling apertures in the mirrors has been studied theoretically in relation to the structure of the modes for both confocal and nonconfocal resonators by Permnoud; use of an open resonator with stepped mirrors has been studied in order to choose a particular longitudinal mode. Studies at the Naval Research Laboratory mirror used configurations that diffraction couple the energy from around the mirror edges, so that the transverse profile inside the resonator can be selective to the fundamental mode.

  14. A quasi-optical electron cyclotron maser for fusion reactor heating. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Morse, E.C.

    1990-12-31

    High power microwave and millimeter sources, such as the quasi-optical electron cyclotron maser (QOECM) are important in fusion research as well as in high-energy physics and in other applications. The interaction between the electromagnetic modes of a Fabry-Perot resonator and an electron beam gyrating through a magnetic field has been studied for both the cases of beams parallel and perpendicular to the resonator. The parallel case was theoretically first studied by Kurin for forward and backward wave interaction, and experimentally by Komlev and Kurin. Kreischer and Temkin reviewed the general case of the linear small signal interaction parallel and perpendicular to the resonator. Sprangle, et al discussed the perpendicular case in a self-consistent linear and nonlinear theoretical study using the Gaussian transverse profile of an open resonator with a single longitudinal mode. Experimental verification of the devices operation was first mentioned in work at the Naval Research Laboratory. Theoretical studies using a time-dependent analysis of a large number of longitudinal modes with similar transverse mode profiles have demonstrated that single longitudinal-mode operation can be achieved at equilibrium and that performance can be enhanced by prebunching the electron beam and tapering the magnetic field. The use of output coupling apertures in the mirrors has been studied theoretically in relation to the structure of the modes for both confocal and nonconfocal resonators by Permnoud; use of an open resonator with stepped mirrors has been studied in order to choose a particular longitudinal mode. Studies at the Naval Research Laboratory mirror used configurations that diffraction couple the energy from around the mirror edges, so that the transverse profile inside the resonator can be selective to the fundamental mode.

  15. Numerical simulations of gas mixing effect in electron cyclotron resonance ion sources

    Directory of Open Access Journals (Sweden)

    V. Mironov

    2017-01-01

    Full Text Available The particle-in-cell Monte Carlo collisions code nam-ecris is used to simulate the electron cyclotron resonance ion source (ECRIS plasma sustained in a mixture of Kr with O_{2}, N_{2}, Ar, Ne, and He. The model assumes that ions are electrostatically confined in the ECR zone by a dip in the plasma potential. A gain in the extracted krypton ion currents is seen for the highest charge states; the gain is maximized when oxygen is used as a mixing gas. The special feature of oxygen is that most of the singly charged oxygen ions are produced after the dissociative ionization of oxygen molecules with a large kinetic energy release of around 5 eV per ion. The increased loss rate of energetic lowly charged ions of the mixing element requires a building up of the retarding potential barrier close to the ECR surface to equilibrate electron and ion losses out of the plasma. In the mixed plasmas, the barrier value is large (∼1  V compared to pure Kr plasma (∼0.01  V, with longer confinement times of krypton ions and with much higher ion temperatures. The temperature of the krypton ions is increased because of extra heating by the energetic oxygen ions and a longer time of ion confinement. In calculations, a drop of the highly charged ion currents of lighter elements is observed when adding small fluxes of krypton into the source. This drop is caused by the accumulation of the krypton ions inside plasma, which decreases the electron and ion confinement times.

  16. Design of coupled cavity with energy modulated electron cyclotron resonance ion source for materials irradiation research

    Directory of Open Access Journals (Sweden)

    Z. Wang (王智

    2012-05-01

    Full Text Available The surface topography of samples after irradiation with heavy ions, protons, and helium ions based on accelerators is an important issue in the study of materials irradiation. We have coupled the separated function radio frequency quadrupole (SFRFQ electrodes and the traditional RFQ electrodes into a single cavity that can provide a 0.8 MeV helium beam for our materials irradiation project. The higher accelerating efficiency has been verified by the successful commissioning of the prototype SFRFQ cavity. An energy modulated electron cyclotron resonance (ECR ion source can achieve a well-bunched beam by loading a sine wave voltage onto the extracted electrodes. Bunching is achieved without the need for an external bunch cavity, which can substantially reduce the cost of the system and the length of the beam line. The coupled RFQ-SFRFQ with an energy modulated ECR ion source will lead to a more compact accelerator system. The conceptual design of this novel structure is presented in this paper.

  17. Early evolution of electron cyclotron driven current during suppression of tearing modes in a circular tokamak

    CERN Document Server

    Pratt, J; Westerhof, E

    2016-01-01

    When electron cyclotron (EC) driven current is first applied to the inside of a magnetic island, the current spreads throughout the island and after a short period achieves a steady level. Using a two equation fluid model for the EC current that allows us to examine this early evolution in detail, we analyze high-resolution simulations of a 2/1 classical tearing mode in a low-beta large aspect-ratio circular tokamak. These simulations use a nonlinear 3D reduced-MHD fluid model and the JOREK code. During the initial period where the EC driven current grows and spreads throughout the magnetic island, it is not a function of the magnetic flux. However, once it has reached a steady-state, it should be a flux function. We demonstrate numerically that if sufficiently resolved toroidally, the steady-state EC driven current becomes approximately a flux function. We discuss the physics of this early period of EC evolution and its impact on the size of the magnetic island.

  18. Electron cyclotron heating/current-drive system using high power tubes for QUEST spherical tokamak

    Science.gov (United States)

    Onchi, Takumi; Idei, H.; Hasegawa, M.; Nagata, T.; Kuroda, K.; Hanada, K.; Kariya, T.; Kubo, S.; Tsujimura, T. I.; Kobayashi, S.; Quest Team

    2017-10-01

    Electron cyclotron heating (ECH) is the primary method to ramp up plasma current non-inductively in QUEST spherical tokamak. A 28 GHz gyrotron is employed for short pulses, where the radio frequency (RF) power is about 300 kW. Current ramp-up efficiency of 0.5 A/W has been obtained with focused beam of the second harmonic X-mode. A quasi-optical polarizer unit has been newly installed to avoid arcing events. For steady-state tokamak operation, 8.56 GHz klystron with power of 200 kW is used as the CW-RF source. The high voltage power supply (54 kV/13 A) for the klystron has been built recently, and initial bench test of the CW-ECH system is starting. The array of insulated-gate bipolar transistor works to quickly cut off the input power for protecting the klystron. This work is supported by JSPS KAKENHI (15H04231), NIFS Collaboration Research program (NIFS13KUTR085, NIFS17KUTR128), and through MEXT funding for young scientists associated with active promotion of national university reforms.

  19. Shut-down dose rate analyses for the ITER electron cyclotron-heating upper launcher

    Energy Technology Data Exchange (ETDEWEB)

    Weinhorst, Bastian; Serikov, Arkady; Fischer, Ulrich; Lu, Lei [Institute for Neutron Physics and Reactor Technology INR (Germany); Karlsruhe Institute of Technology KIT (Germany); Spaeh, Peter; Strauss, Dirk [Institute for Applied Materials IAM (Germany); Karlsruhe Institute of Technology KIT (Germany)

    2014-10-15

    The electron cyclotron resonance heating upper launcher (ECHUL) is going to be installed in the upper port of the ITER tokamak thermonuclear fusion reactor for plasma mode stabilization (neoclassical tearing modes and the sawtooth instability). The paper reports the latest neutronic modeling and analyses which have been performed for the ITER reference front steering launcher design. It focuses on the port accessibility after reactor shut-down for which dose rate (SDDR) distributions on a fine regular mesh grid were calculated. The results are compared to those obtained for the ITER Dummy Upper Port. The calculations showed that the heterogeneous ECHUL design gives rise to enhanced radiation streaming as compared to the homogenous dummy upper port. Therefore the used launcher geometry was upgraded to a more recent development stage. The inter-comparison shows a significant improvement of the launchers shielding properties but also the necessity to further upgrade the shielding performance. Furthermore, the analysis for the homogenous dummy upper port, which represents optimal shielding inside the launcher, demonstrates that the shielding upgrade also needs to include the launcher's environment.

  20. Real-time beam tracing for control of the deposition location of electron cyclotron waves

    Energy Technology Data Exchange (ETDEWEB)

    Reich, M., E-mail: matthias.reich@ipp.mpg.de; Bilato, R.; Mszanowski, U.; Poli, E.; Rapson, C.; Stober, J.; Volpe, F.; Zille, R.

    2015-11-15

    Highlights: • We successfully integrated a real-time EC beam tracing code at ASDEX Upgrade. • The calculation of EC beam deposition location is fast enough for control purposes. • The accuracy of the deposition location calculation exceeds equivalent measurements. • The implementation method is by design portable to larger fusion devices. - Abstract: Plasma control techniques that use electron cyclotron (EC) resonance heating and current drive such as control of neoclassical tearing modes require accurate control of the deposition location of EC beams. ASDEX Upgrade has successfully implemented a real-time version of the beam-tracing code TORBEAM into its real-time diagnostic system to act as a globally available module that calculates current deposition location and its sensitivity from other real-time diagnostic measurements for all its moveable EC wave launchers. Based on a highly (100×) accelerated version of TORBEAM, the software implementation as a diagnostic process uses parallelization and achieves cycle times of 15–20 ms for determining the radial deposition location of 12 beams in the plasma. This cycle time includes data input–output overhead arising from the use of available real-time signals. The system is by design portable to other machines such as ITER.

  1. First results from the new RIKEN superconducting electron cyclotron resonance ion source (invited).

    Science.gov (United States)

    Nakagawa, T; Higurashi, Y; Ohnishi, J; Aihara, T; Tamura, M; Uchiyama, A; Okuno, H; Kusaka, K; Kidera, M; Ikezawa, E; Fujimaki, M; Sato, Y; Watanabe, Y; Komiyama, M; Kase, M; Goto, A; Kamigaito, O; Yano, Y

    2010-02-01

    The next generation heavy ion accelerator facility, such as the RIKEN radio isotope (RI) beam factory, requires an intense beam of high charged heavy ions. In the past decade, performance of the electron cyclotron resonance (ECR) ion sources has been dramatically improved with increasing the magnetic field and rf frequency to enhance the density and confinement time of plasma. Furthermore, the effects of the key parameters (magnetic field configuration, gas pressure, etc.) on the ECR plasma have been revealed. Such basic studies give us how to optimize the ion source structure. Based on these studies and modern superconducting (SC) technology, we successfully constructed the new 28 GHz SC-ECRIS, which has a flexible magnetic field configuration to enlarge the ECR zone and to optimize the field gradient at ECR point. Using it, we investigated the effect of ECR zone size, magnetic field configuration, and biased disk on the beam intensity of the highly charged heavy ions with 18 GHz microwaves. In this article, we present the structure of the ion source and first experimental results with 18 GHz microwave in detail.

  2. Modification of argon impurity transport by electron cyclotron heating in KSTAR H-mode plasmas

    Science.gov (United States)

    Hong, Joohwan; Henderson, S. S.; Kim, Kimin; Seon, C. R.; Song, Inwoo; Lee, H. Y.; Jang, Juhyeok; Park, Jae Sun; Lee, S. G.; Lee, J. H.; Lee, Seung Hun; Hong, Suk-Ho; Choe, Wonho

    2017-03-01

    Experiments with a small amount of Ar gas injection as a trace impurity were conducted in the Korea Superconducting Tokamak Advanced Research (KSTAR) H-mode plasma ({{B}\\text{T}}   =  2.8 T, {{I}\\text{P}}   =  0.6 MA, and {{P}\\text{NBI}}   =  4.0 MW). 170 GHz electron cyclotron resonance heating (ECH) at 600 and 800 kW was focused along the mid-plane with a fixed major radial position of R   =  1.66 m. The emissivity of the Ar16+ (3.949 {\\mathring{\\text{A}}} ) and Ar15+ (353.860 {\\mathring{\\text{A}}} ) spectral lines were measured by x-ray imaging crystal spectroscopy (XICS) and a vacuum UV (VUV) spectrometer, respectively. ECH reduces the peak Ar15+ emission and increases the Ar16+ emission, an effect largest with 800 kW. The ADAS-SANCO impurity transport code was used to evaluate the Ar transport coefficients. It was found that the inward convective velocity found in the plasma core without ECH was decreased with ECH, while diffusion remained approximately constant resulting in a less-peaked Ar density profile. Theoretical results from the NEO code suggest that neoclassical transport is not responsible for the change in transport, while the microstability analysis using GKW predicts a dominant ITG mode during both ECH and non-ECH plasmas.

  3. Enhancement of octacalcium phosphate deposition on a titanium surface activated by electron cyclotron resonance plasma oxidation.

    Science.gov (United States)

    Orii, Yusuke; Masumoto, Hiroshi; Honda, Yoshitomo; Anada, Takahisa; Goto, Takashi; Sasaki, Keiichi; Suzuki, Osamu

    2010-05-01

    The present study was designed to investigate whether the formation of octacalcium phosphate (OCP) is accelerated on titanium (Ti) surface by an electron cyclotron resonance (ECR) plasma oxidation at various pressures and temperatures. X-ray diffraction (XRD) of Ti-oxidized substrates showed that the rutile TiO(2) phase on its surfaces appeared at 300 degrees C and was crystallized when the oxidation temperature increased up to 600 degrees C. The thickness of TiO(2) film on the substrates increased progressively as the temperature increased. The oxidized Ti surfaces were soaked in calcium and phosphate solutions supersaturated with respect to both hydroxyapatite (HA) and OCP but slightly supersaturated with dicalcium phosphate dihydrate (DCPD). OCP crystals with a blade-like morphology were deposited as the primary crystalline phase on Ti substrates, while DCPD was included as a minor constituent. The amount of OCP deposition was maximized under 0.015 Pa in 300 degrees C. On the other hand, the oxidation temperature did not show a significant effect on the deposit in the range examined. The phase conversion from OCP to HA, determined by XRD, was demonstrated to occur even at 1 day and to advance until 7 days by immersing the Ti substrate with the deposit in simulated body fluid at 37 degrees C. The present results suggest that ECR plasma oxidation could be used to improve a Ti surface regarding its bioactivity due to the enhancement of osteoconductive OCP deposition. (c) 2010 Wiley Periodicals, Inc.

  4. Electron cyclotron power management for control of neoclassical tearing modes in the ITER baseline scenario

    Science.gov (United States)

    Poli, F. M.; Fredrickson, E. D.; Henderson, M. A.; Kim, S.-H.; Bertelli, N.; Poli, E.; Farina, D.; Figini, L.

    2018-01-01

    Time-dependent simulations are used to evolve plasma discharges in combination with a modified Rutherford equation for calculation of neoclassical tearing mode (NTM) stability in response to electron cyclotron (EC) feedback control in ITER. The main application of this integrated approach is to support the development of control algorithms by analyzing the plasma response with physics-based models and to assess how uncertainties in the detection of the magnetic island and in the EC alignment affect the ability of the ITER EC system to fulfill its purpose. Simulations indicate that it is critical to detect the island as soon as possible, before its size exceeds the EC deposition width, and that maintaining alignment with the rational surface within half of the EC deposition width is needed for stabilization and suppression of the modes, especially in the case of modes with helicity (2, 1) . A broadening of the deposition profile, for example due to wave scattering by turbulence fluctuations or not well aligned beams, could even be favorable in the case of the (2, 1)- NTM, by relaxing an over-focussing of the EC beam and improving the stabilization at the mode onset. Pre-emptive control reduces the power needed for suppression and stabilization in the ITER baseline discharge to a maximum of 5 MW, which should be reserved and available to the upper launcher during the entire flattop phase. Assuming continuous triggering of NTMs, with pre-emptive control ITER would be still able to demonstrate a fusion gain of Q=10 .

  5. Final report to US Department of Energy: Cyclotron autoresonance accelerator for electron beam dry scrubbing of flue gases

    Energy Technology Data Exchange (ETDEWEB)

    Hirshfield, J.L.

    2001-05-25

    Several designs have been built and operated of microwave cyclotron autoresonance accelerators (CARA's) with electron beam parameters suitable for remediation of pollutants in flue gas emissions from coal-burning power plants. CARA designs have also been developed with a TW-level 10.6 micron laser driver for electron acceleration from 50 to 100 MeV, and with UHF drivers for proton acceleration to over 500 MeV. Dose requirements for reducing SO2, NOx, and particulates in flue gas emissions to acceptable levels have been surveyed, and used to optimize the design of an electron beam source to deliver this dose.

  6. Pitch-angle diffusion coefficients from resonant interactions with electrostatic electron cyclotron harmonic waves in planetary magnetospheres

    Directory of Open Access Journals (Sweden)

    A. K. Tripathi

    2011-02-01

    Full Text Available Pitch-angle diffusion coefficients have been calculated for resonant interaction with electrostatic electron cyclotron harmonic (ECH waves in the magnetospheres of Earth, Jupiter, Saturn, Uranus and Neptune. Calculations have been performed at two radial distances of each planet. It is found that observed wave electric field amplitudes in the magnetospheres of Earth and Jupiter are sufficient to put electrons on strong diffusion in the energy range of less than 100 eV. However, for Saturn, Uranus and Neptune, the observed ECH wave amplitude are insufficient to put electrons on strong diffusion at any radial distance.

  7. On the influence of the shape of kappa distributions of ions and electrons on the ion-cyclotron instability

    Science.gov (United States)

    Ziebell, L. F.; Gaelzer, R.

    2017-10-01

    The dispersion relation for ion-cyclotron waves propagating along the direction of the ambient magnetic field is investigated numerically by considering different forms of kappa functions as velocity distributions of ions and electrons. General forms of kappa distributions, isotropic and anisotropic, are defined and used to obtain the dispersion relations for ion-cyclotron waves. With suitable choice of parameters, the general forms reduce to anisotropic versions of the kappa distributions most frequently employed in the literature. The analysis is focused in cases with a small value of the kappa index, for which the non thermal character of the kappa distributions is enhanced. The results show the effects of the superthermal tails of the velocity distributions of both particle species (ions and electrons) on the growth rate of the ion-cyclotron instability. It is seen that different forms of anisotropic kappa distributions, which are used in the current literature, can have a significantly different effect on the growth rates of the instability.

  8. Soft x-ray intensity profile measurements of electron cyclotron heated plasmas using semiconductor detector arrays in GAMMA 10 tandem mirror

    Energy Technology Data Exchange (ETDEWEB)

    Minami, R., E-mail: minami@prc.tsukuba.ac.jp; Imai, T.; Kariya, T.; Numakura, T.; Eguchi, T.; Kawarasaki, R.; Nakazawa, K.; Kato, T.; Sato, F.; Nanzai, H.; Uehara, M.; Endo, Y.; Ichimura, M. [Plasma Research Center, University of Tsukuba, Tsukuba, Ibaraki 305-8577 (Japan)

    2014-11-15

    Temporally and spatially resolved soft x-ray analyses of electron cyclotron heated plasmas are carried out by using semiconductor detector arrays in the GAMMA 10 tandem mirror. The detector array has 16-channel for the measurements of plasma x-ray profiles so as to make x-ray tomographic reconstructions. The characteristics of the detector array make it possible to obtain spatially resolved plasma electron temperatures down to a few tens eV and investigate various magnetohydrodynamic activities. High power electron cyclotron heating experiment for the central-cell region in GAMMA 10 has been started in order to reduce the electron drag by increasing the electron temperature.

  9. Direct measurement of refracted trajectory of transmitting electron cyclotron beam through plasma on the Large Helical Device

    Directory of Open Access Journals (Sweden)

    Takahashi Hiromi

    2015-01-01

    Full Text Available The electron-cyclotron (EC -beam refraction due to the presence of plasma was investigated in the Large Helical Device. The transmitted-EC-beam measurement system was constructed and the beam pattern on the opposite side of the irradiated surface was measured using an IR camera. Clear dependence of the EC-beam refraction on the electron density was observed and the beam shift in the toroidal direction showed good agreement with the ray-trace calculation of TRAVIS. The influence of the peripheral density profile and the thermal effect on the beam refraction were discussed.

  10. Production of highly charged heavy ions by 18 GHz superconducting electron cyclotron resonance at Research Center for Nuclear Physics.

    Science.gov (United States)

    Yorita, Tetsuhiko; Hatanaka, Kichiji; Fukuda, Mitsuhiro; Kibayashi, Mitsuru; Morinobu, Shunpei; Okamura, Hiroyuki; Tamii, Atsushi

    2010-02-01

    An 18 GHz superconducting electron cyclotron resonance ion source has been installed as a subject of the azimuthally varying field cyclotron upgrade project (K. Hatanaka et al., in Proceedings of the 17th International Conference on Cyclotrons and Their Applications, Tokyo, Japan, 18-22 October 2004, pp. 115-117), in order to increase beam currents and to extend the variety of ions. The production development of several ions has been performed since 2006 and some of them have already been used for user experiments [T. Yorita et al., Rev. Sci. Instrum. 79, 02A311 (2008)]. Further optimizations for each component such as the material of plasma electrode, material, and shape of bias probe and mirror field have been continued and more intense ion beams have been obtained for O, N, and Ar. For the purpose of obtaining highly charged Xe with several microamperes, the optimization of position and shape of plasma electrode and bias disk has also been done and highly charged Xe(32+) beam has been obtained successfully.

  11. Development of electronics and data acquisition system for independent calibration of electron cyclotron emission radiometer

    Energy Technology Data Exchange (ETDEWEB)

    Kumari, Praveena, E-mail: praveena@ipr.res.in; Raulji, Vismaysinh; Mandaliya, Hitesh; Patel, Jignesh; Siju, Varsha; Pathak, S.K.; Rajpal, Rachana; Jha, R.

    2016-11-15

    Highlights: • Indigenous development of an electronics and data acquisition system to digitize signals for a desired time and automatization of calibration process. • 16 bit DAQ board with form factor of 90 × 89 mm. • VHDL Codes written for generating control signals for PC104 Bus, ADC and RAM. • Averaging process is done in two ways single point averaging and additive averaging. - Abstract: Signal conditioning units (SCU) along with Multichannel Data acquisition system (DAS) are developed and installed for automatization and frequent requirement of absolute calibration of ECE radiometer system. The DAS is an indigenously developed economical system which is based on Single Board Computer (SBC). The onboard RAM memory of 64 K for each channel enables the DAS for simultaneous and continuous acquisition. A Labview based graphical user interface provides commands locally or remotely to acquire, process, plot and finally save the data in binary format. The microscopic signals received from radiometer are strengthened, filtered by SCU and acquired through DAS for the set time and at set sampling frequency. Stored data are processed and analyzed offline with Labview utility. The calibration process has been performed for two hours continuously at different sampling frequency (100 Hz to 1 KHz) at two set of temperature like hot body and the room temperature. The detailed hardware and software design and testing results are explained in the paper.

  12. Three-dimensional simulations of ion dynamics in the plasma of an electron cyclotron resonance ion source

    Directory of Open Access Journals (Sweden)

    V. Mironov

    2009-07-01

    Full Text Available The ion production in an electron cyclotron resonance ion source (ECRIS is modeled using a particle-in-cell Monte-Carlo-collision code in a three-dimensional geometry. Only the heavy particles (ions and atoms are tracked, while the electrons are represented using a Maxwell-Boltzmann energy distribution with the electron density determined from the requirement of quasineutrality, and the electron temperature considered as a free parameter. It is found that experimentally observed features of ECRIS plasma are closely reproduced by the code, including the charge-state distributions of extracted ion beams and sputtering patterns inside the source. The isotope anomaly is observed for the mixture of ^{20}Ne+^{22}Ne isotopes, and a possible explanation is proposed. Finally, the wall-coating effect is treated by modeling the neutralization of ions impinging on the walls of the plasma chamber.

  13. Design and Research of Electron Cyclotron Resonance Heating and Current Dive System on HL-2M Tokamak

    Science.gov (United States)

    Huang, Mei; Rao, Jao; Song, Shaodong; Wang, He; Chen, Gangyu; Kang, Zhihua; Zhang, Feng; Wang, Jieqiong; Ye, Jiruo; Feng, Kun; Lu, Bo; Huang, Bo; Wang, Chao; Wang, Mingwei; Xuan, Weimin; Rao, Lieying; Li, Qing; Mao, Xiaohui; Duan, Xuru; Liu, Yong

    2017-07-01

    A research has been conducted to develop an 8MW electron cyclotron resonance heating and current drive (ECRH/ECCD) system on HL-2M tokamak. The ECRH system compromise eight 1MW gyrotrons, eight evacuated transmission lines and three launchers. The main purpose of the ECRH system was to suppress the neo-classical tearing modes and control the plasma profile. This paper presents an overview of the design and studies performed in this framework. Some primary test results of the critical components have been released in this paper, e.g. polarizers, power monitor and fast steering launchers.

  14. Toroidal mode number estimation of the edge-localized modes using the KSTAR 3-D electron cyclotron emission imaging system.

    Science.gov (United States)

    Lee, J; Yun, G S; Lee, J E; Kim, M; Choi, M J; Lee, W; Park, H K; Domier, C W; Luhmann, N C; Sabbagh, S A; Park, Y S; Lee, S G; Bak, J G

    2014-06-01

    A new and more accurate technique is presented for determining the toroidal mode number n of edge-localized modes (ELMs) using two independent electron cyclotron emission imaging (ECEI) systems in the Korea Superconducting Tokamak Advanced Research (KSTAR) device. The technique involves the measurement of the poloidal spacing between adjacent ELM filaments, and of the pitch angle α* of filaments at the plasma outboard midplane. Equilibrium reconstruction verifies that α* is nearly constant and thus well-defined at the midplane edge. Estimates of n obtained using two ECEI systems agree well with n measured by the conventional technique employing an array of Mirnov coils.

  15. Emittance study of a 28 GHz electron cyclotron resonance ion source for the Rare Isotope Science Project superconducting linear accelerator.

    Science.gov (United States)

    Park, Bum-Sik; Hong, In-Seok; Jang, Ji-Ho; Jin, Hyunchang; Choi, Sukjin; Kim, Yonghwan

    2016-02-01

    A 28 GHz electron cyclotron resonance (ECR) ion source is being developed for use as an injector for the superconducting linear accelerator of the Rare Isotope Science Project. Beam extraction from the ECR ion source has been simulated using the KOBRA3-INP software. The simulation software can calculate charged particle trajectories in three dimensional complex magnetic field structures, which in this case are formed by the arrangement of five superconducting magnets. In this study, the beam emittance is simulated to understand the effects of plasma potential, mass-to-charge ratio, and spatial distribution. The results of these simulations and their comparison to experimental results are presented in this paper.

  16. Nb3Sn superconducting magnets for electron cyclotron resonance ion sources.

    Science.gov (United States)

    Ferracin, P; Caspi, S; Felice, H; Leitner, D; Lyneis, C M; Prestemon, S; Sabbi, G L; Todd, D S

    2010-02-01

    Electron cyclotron resonance (ECR) ion sources are an essential component of heavy-ion accelerators. Over the past few decades advances in magnet technology and an improved understanding of the ECR ion source plasma physics have led to remarkable performance improvements of ECR ion sources. Currently third generation high field superconducting ECR ion sources operating at frequencies around 28 GHz are the state of the art ion injectors and several devices are either under commissioning or under design around the world. At the same time, the demand for increased intensities of highly charged heavy ions continues to grow, which makes the development of even higher performance ECR ion sources a necessity. To extend ECR ion sources to frequencies well above 28 GHz, new magnet technology will be needed in order to operate at higher field and force levels. The superconducting magnet program at LBNL has been developing high field superconducting magnets for particle accelerators based on Nb(3)Sn superconducting technology for several years. At the moment, Nb(3)Sn is the only practical conductor capable of operating at the 15 T field level in the relevant configurations. Recent design studies have been focused on the possibility of using Nb(3)Sn in the next generation of ECR ion sources. In the past, LBNL has worked on the VENUS ECR, a 28 GHz source with solenoids and a sextupole made with NbTi operating at fields of 6-7 T. VENUS has now been operating since 2004. We present in this paper the design of a Nb(3)Sn ECR ion source optimized to operate at an rf frequency of 56 GHz with conductor peak fields of 13-15 T. Because of the brittleness and strain sensitivity of Nb(3)Sn, particular care is required in the design of the magnet support structure, which must be capable of providing support to the coils without overstressing the conductor. In this paper, we present the main features of the support structure, featuring an external aluminum shell pretensioned with water

  17. Electron cyclotron resonance ion source plasma characterization by X-ray spectroscopy and X-ray imaging

    Energy Technology Data Exchange (ETDEWEB)

    Mascali, David, E-mail: davidmascali@lns.infn.it; Castro, Giuseppe; Celona, Luigi; Neri, Lorenzo; Gammino, Santo [INFN–Laboratori Nazionali del Sud, Via S. Sofia 62, 95125 Catania (Italy); Biri, Sándor; Rácz, Richárd; Pálinkás, József [Institute for Nuclear Research (Atomki), Hungarian Academy of Sciences, Bem tér 18/c, H-4026 Debrecen (Hungary); Caliri, Claudia [INFN–Laboratori Nazionali del Sud, Via S. Sofia 62, 95125 Catania (Italy); Università degli Studi di Catania, Dip.to di Fisica e Astronomia, via Santa Sofia 64, 95123 Catania (Italy); Romano, Francesco Paolo [INFN–Laboratori Nazionali del Sud, Via S. Sofia 62, 95125 Catania (Italy); CNR, Istituto per i Beni Archeologici e Monumentali, Via Biblioteca 4, 95124 Catania (Italy); Torrisi, Giuseppe [INFN–Laboratori Nazionali del Sud, Via S. Sofia 62, 95125 Catania (Italy); Università Mediterranea di Reggio Calabria, DIIES, Via Graziella, I-89100 Reggio Calabria (Italy)

    2016-02-15

    An experimental campaign aiming to investigate electron cyclotron resonance (ECR) plasma X-ray emission has been recently carried out at the ECRISs—Electron Cyclotron Resonance Ion Sources laboratory of Atomki based on a collaboration between the Debrecen and Catania ECR teams. In a first series, the X-ray spectroscopy was performed through silicon drift detectors and high purity germanium detectors, characterizing the volumetric plasma emission. The on-purpose developed collimation system was suitable for direct plasma density evaluation, performed “on-line” during beam extraction and charge state distribution characterization. A campaign for correlating the plasma density and temperature with the output charge states and the beam intensity for different pumping wave frequencies, different magnetic field profiles, and single-gas/gas-mixing configurations was carried out. The results reveal a surprisingly very good agreement between warm-electron density fluctuations, output beam currents, and the calculated electromagnetic modal density of the plasma chamber. A charge-coupled device camera coupled to a small pin-hole allowing X-ray imaging was installed and numerous X-ray photos were taken in order to study the peculiarities of the ECRIS plasma structure.

  18. The effects of electron cyclotron heating and current drive on toroidal Alfvén eigenmodes in tokamak plasmas

    Science.gov (United States)

    Sharapov, S. E.; Garcia-Munoz, M.; Van Zeeland, M. A.; Bobkov, B.; Classen, I. G. J.; Ferreira, J.; Figueiredo, A.; Fitzgerald, M.; Galdon-Quiroga, J.; Gallart, D.; Geiger, B.; Gonzalez-Martin, J.; Johnson, T.; Lauber, P.; Mantsinen, M.; Nabais, F.; Nikolaeva, V.; Rodriguez-Ramos, M.; Sanchis-Sanchez, L.; Schneider, P. A.; Snicker, A.; Vallejos, P.; the AUG Team; the EUROfusion MST1 Team

    2018-01-01

    Dedicated studies performed for toroidal Alfvén eigenmodes (TAEs) in ASDEX-Upgrade (AUG) discharges with monotonic q-profiles have shown that electron cyclotron resonance heating (ECRH) can make TAEs more unstable. In these AUG discharges, energetic ions driving TAEs were obtained by ion cyclotron resonance heating (ICRH). It was found that off-axis ECRH facilitated TAE instability, with TAEs appearing and disappearing on timescales of a few milliseconds when the ECRH power was switched on and off. On-axis ECRH had a much weaker effect on TAEs, and in AUG discharges performed with co- and counter-current electron cyclotron current drive (ECCD), the effects of ECCD were found to be similar to those of ECRH. Fast ion distributions produced by ICRH were computed with the PION and SELFO codes. A significant increase in T e caused by ECRH applied off-axis is found to increase the fast ion slowing-down time and fast ion pressure causing a significant increase in the TAE drive by ICRH-accelerated ions. TAE stability calculations show that the rise in T e causes also an increase in TAE radiative damping and thermal ion Landau damping, but to a lesser extent than the fast ion drive. As a result of the competition between larger drive and damping effects caused by ECRH, TAEs become more unstable. It is concluded, that although ECRH effects on AE stability in present-day experiments may be quite significant, they are determined by the changes in the plasma profiles and are not particularly ECRH specific.

  19. Observation and characterization of the effect of electron cyclotron waves on toroidal rotation in EAST L-mode discharges

    Science.gov (United States)

    Chen, Jun; Hu, Ruiji; Lyu, Bo; Wang, Fudi; Wang, Xiaojie; Xu, Handong; Li, Yingying; Fu, Jia; Yin, Xianghui; Wu, Dajun; Liu, Fukun; Zang, Qing; Liu, Haiqing; Shi, Yuejiang; Mao, Shifeng; Yu, Yi; Wang, Baonian; Ye, Minyou; Shen, Yongcai; EAST Team

    2017-10-01

    The change in the toroidal rotation of plasma caused by electron cyclotron wave (ECW) injection has been observed in EAST. It is found that the response of the rotation is similar for all possible ECW toroidal injection angles. The core toroidal rotation velocity increases in the co-current direction along with a rise in the plasma temperature and stored energy. The profile of the electron temperature, ion temperature and toroidal rotation velocity gradually become peaked. The change in toroidal rotation in the core increases with the ECW injection power. Different behavior is observed when the ECWs are injected into low hybrid current drive (LHCD) target plasmas, where the electron temperature and rotation profile become peaked, while the ion temperature profile flattens after ECW injection, suggesting different transport characteristics in energy and momentum.

  20. Ion cyclotron range of frequencies mode conversion electron heating in deuterium-hydrogen plasmas in the Alcator C-Mod tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Y [Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, MA 02139 (United States); Wukitch, S J [Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, MA 02139 (United States); Bonoli, P T [Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, MA 02139 (United States); Marmar, E [Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, MA 02139 (United States); Mossessian, D [Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, MA 02139 (United States); Nelson-Melby, E [Centre de Recherches en Physique des Plasmas, Association EURATOM - Confederation Suisse, Ecole Polytechnique Federale de Lausanne, CH-1015 Lausanne (Switzerland); Phillips, P [Fusion Research Center, University of Texas, Austin, Texas 78712 (United States); Porkolab, M [Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, MA 02139 (United States); Schilling, G [Plasma Physics Laboratory, Princeton, NJ 08543 (United States); Wolfe, S [Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, MA 02139 (United States); Wright, J [Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, MA 02139 (United States)

    2003-06-01

    Localized direct electron heating (EH) by mode-converted (MC) ion cyclotron range of frequencies (ICRF) waves in D(H) tokamak plasmas has been clearly observed for the first time in Alcator C-Mod. Both on- and off-axis (high field side) mode conversion EH (MCEH) have been observed. The MCEH profile was obtained from a break-in-slope analysis of electron temperature signals in the presence of radio frequency shut-off. The temperature was measured by a 32-channel high spatial resolution ({<=}7 mm) 2nd harmonic heterodyne electron cyclotron emission system. The experimental profiles were compared with the predictions from a toroidal full-wave ICRF code TORIC. Using the hydrogen concentration measured by a high-resolution optical spectrometer, TORIC predictions were shown qualitatively in agreement with the experimental results for both on- and off-axis MC cases. From the simulations, the EH from MC ion cyclotron wave and ion Bernstein wave is examined.

  1. Bayesian fuzzy logic-based estimation of electron cyclotron heating (ECH) power deposition in MHD control systems

    Energy Technology Data Exchange (ETDEWEB)

    Davoudi, Mehdi, E-mail: mehdi.davoudi@polimi.it [Department of Electrical and Computer Engineering, Buein Zahra Technical University, Buein Zahra, Qazvin (Iran, Islamic Republic of); Davoudi, Mohsen, E-mail: davoudi@eng.ikiu.ac.ir [Department of Electrical Engineering, Imam Khomeini International University, Qazvin, 34148-96818 (Iran, Islamic Republic of)

    2017-06-15

    Highlights: • A couple of algorithms to diagnose if Electron Cyclotron Heating (ECH) power is deposited properly on the expected deposition minor radius are proposed. • The algorithms are based on Bayesian theory and Fuzzy logic. • The algorithms are tested on the off-line experimental data acquired from Frascati Tokamak Upgrade (FTU), Frascati, Italy. • Uncertainties and evidences derived from the combination of online information formed by the measured diagnostic data and the prior information are also estimated. - Abstract: In the thermonuclear fusion systems, the new plasma control systems use some measured on-line information acquired from different sensors and prior information obtained by predictive plasma models in order to stabilize magnetic hydro dynamics (MHD) activity in a tokamak. Suppression of plasma instabilities is a key issue to improve the confinement time of controlled thermonuclear fusion with tokamaks. This paper proposes a couple of algorithms based on Bayesian theory and Fuzzy logic to diagnose if Electron Cyclotron Heating (ECH) power is deposited properly on the expected deposition minor radius (r{sub DEP}). Both algorithms also estimate uncertainties and evidences derived from the combination of the online information formed by the measured diagnostic data and the prior information. The algorithms have been employed on a set of off-line ECE channels data which have been acquired from the experimental shot number 21364 at Frascati Tokamak Upgrade (FTU), Frascati, Italy.

  2. Improved cross-calibration of Thomson scattering and electron cyclotron emission with ECH on DIII-D

    Energy Technology Data Exchange (ETDEWEB)

    Brookman, M. W., E-mail: brookmanmw@fusion.gat.com [Institute for Fusion Studies, University of Texas at Austin, Austin, Texas 78712 (United States); Austin, M. E.; McLean, A. G. [Lawrence Livermore National Lab, Livermore, California 94500 (United States); Carlstrom, T. N.; Hyatt, A. W.; Lohr, J. [General Atomics, San Diego, California 92122 (United States)

    2016-11-15

    Thomson scattering produces n{sub e} profiles from measurement of scattered laser beam intensity. Rayleigh scattering provides a first calibration of the relation n{sub e} ∝ I{sub TS}, which depends on many factors (e.g., laser alignment and power, optics, and measurement systems). On DIII-D, the n{sub e} calibration is adjusted against an absolute n{sub e} from the density-driven cutoff of the 48 channel 2nd harmonic X-mode electron cyclotron emission system. This method has been used to calibrate Thomson n{sub e} from the edge to near the core (r/a > 0.15). Application of core electron cyclotron heating improves the quality of cutoff and depth of its penetration into the core, and also changes underlying MHD activity, minimizing crashes which confound calibration. Less fueling is needed as “ECH pump-out” generates a plasma ready to take up gas. On removal of gyrotron power, cutoff penetrates into the core as channels fall successively and smoothly into cutoff.

  3. Topological Berry phase and semiclassical quantization of cyclotron orbits for two dimensional electrons in coupled band models

    Science.gov (United States)

    Fuchs, J. N.; Piéchon, F.; Goerbig, M. O.; Montambaux, G.

    2010-10-01

    The semiclassical quantization of cyclotron orbits for two-dimensional Bloch electrons in a coupled two band model with a particle-hole symmetric spectrum is considered. As concrete examples, we study graphene (both mono and bilayer) and boron nitride. The main focus is on wave effects - such as Berry phase and Maslov index - occurring at order hbar in the semiclassical quantization and producing non-trivial shifts in the resulting Landau levels. Specifically, we show that the index shift appearing in the Landau levels is related to a topological part of the Berry phase - which is basically a winding number of the direction of the pseudo-spin 1/2 associated to the coupled bands - acquired by an electron during a cyclotron orbit and not to the complete Berry phase, as commonly stated. As a consequence, the Landau levels of a coupled band insulator are shifted as compared to a usual band insulator. We also study in detail the Berry curvature in the whole Brillouin zone on a specific example (boron nitride) and show that its computation requires care in defining the “ k-dependent Hamiltonian” H( k), where k is the Bloch wavevector.

  4. Integral staggered point-matching method for millimeter-wave reflective diffraction gratings on electron cyclotron heating systems

    Energy Technology Data Exchange (ETDEWEB)

    Xia, Donghui [State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, 430074 Wuhan (China); Huang, Mei [Southwestern Institute of Physics, 610041 Chengdu (China); Wang, Zhijiang, E-mail: wangzj@hust.edu.cn [State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, 430074 Wuhan (China); Zhang, Feng [Southwestern Institute of Physics, 610041 Chengdu (China); Zhuang, Ge [State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, 430074 Wuhan (China)

    2016-10-15

    Highlights: • The integral staggered point-matching method for design of polarizers on the ECH systems is presented. • The availability of the integral staggered point-matching method is checked by numerical calculations. • Two polarizers are designed with the integral staggered point-matching method and the experimental results are given. - Abstract: The reflective diffraction gratings are widely used in the high power electron cyclotron heating systems for polarization strategy. This paper presents a method which we call “the integral staggered point-matching method” for design of reflective diffraction gratings. This method is based on the integral point-matching method. However, it effectively removes the convergence problems and tedious calculations of the integral point-matching method, making it easier to be used for a beginner. A code is developed based on this method. The calculation results of the integral staggered point-matching method are compared with the integral point-matching method, the coordinate transformation method and the low power measurement results. It indicates that the integral staggered point-matching method can be used as an optional method for the design of reflective diffraction gratings in electron cyclotron heating systems.

  5. ITER Plasma at Electron Cyclotron Frequency Domain: Stimulated Raman Scattering off Gould-Trivelpiece Modes and Generation of Suprathermal Electrons and Energetic Ions

    Science.gov (United States)

    Stefan, V. Alexander

    2011-04-01

    Stimulated Raman scattering in the electron cyclotron frequency range of the X-Mode and O-Mode driver with the ITER plasma leads to the ``tail heating'' via the generation of suprathermal electrons and energetic ions. The scattering off Trivelpiece-Gould (T-G) modes is studied for the gyrotron frequency of 170GHz; X-Mode and O-Mode power of 24 MW CW; on-axis B-field of 10T. The synergy between the two-plasmon decay and Raman scattering is analyzed in reference to the bulk plasma heating. Supported in part by Nikola TESLA Labs, La Jolla, CA

  6. High-harmonic electron bunching in the field of a signal wave and the use of this effect in cyclotron masers with frequency multiplication

    Directory of Open Access Journals (Sweden)

    I. V. Bandurkin

    2005-01-01

    Full Text Available A method of organizing electron-wave interaction at the multiplied frequency of the signal wave is proposed. This type of electron-wave interaction provides multiplied-frequency electron bunching, which leads to formation of an intense harmonic of the electron current at a selected multiplied frequency of the signal wave. This effect is attractive for the use in klystron-type cyclotron masers with frequency multiplication as a way to increase the output frequency and improve the selectivity.

  7. Monitoring of the current profile by using cyclotronic electron waves in tokamaks; Controle du profil de courant par ondes cyclotroniques electroniques dans les tokamaks

    Energy Technology Data Exchange (ETDEWEB)

    Dumont, R

    2001-08-01

    The subject of this thesis is the study of the cyclotronic electron wave as a monitoring tool of the current profile. The first chapter is dedicated to basic notions concerning tokamak plasmas and current generation. The second chapter is centered on the use of fast electrons to generate current and on its modelling. The propagation and absorption of the cyclotronic electron wave require a specific polarization state whose characteristics must be carefully chosen according to some parameters of the discharge, the chapter 3 deals with this topic. The absorption of a wave in a plasma depends greatly on the velocity distribution of the particles that make up the plasma and this distribution is constantly modified by the energy of the wave, so this phenomenon is non-linear and its physical description is difficult. In a case of a fusion plasma, a sophisticated approximation called quasi-linear theory can be applied with some restrictions that are presented in chapter 4. Chapters 5 and 6 are dedicated to kinetics scenarios involving the low hybrid wave and the cyclotronic electron wave inside the plasma. Some experiments dedicated to the study of the cyclotronic electron wave have been performed in Tore-supra (France) and FTU (Italy) tokamaks, they are presented in the last chapter. (A.C.)

  8. Generation of lower and upper bands of electrostatic electron cyclotron harmonic waves in the Van Allen radiation belts

    Science.gov (United States)

    Zhou, Qinghua; Xiao, Fuliang; Yang, Chang; Liu, Si; He, Yihua; Baker, D. N.; Spence, H. E.; Reeves, G. D.; Funsten, H. O.

    2017-06-01

    Electrostatic electron cyclotron harmonic (ECH) waves generated by the electron loss cone distribution can produce efficient scattering loss of plasma sheet electrons, which has a significant effect on the dynamics in the outer magnetosphere. Here we report two ECH emission events around the same location L≈ 5.7-5.8, MLT ≈ 12 from Van Allen Probes on 11 February (event A) and 9 January 2014 (event B), respectively. The spectrum of ECH waves was centered at the lower half of the harmonic bands during event A, but the upper half during event B. The observed electron phase space density in both events is fitted by the subtracted bi-Maxwellian distribution, and the fitting functions are used to evaluate the local growth rates of ECH waves based on a linear theory for homogeneous plasmas. ECH waves are excited by the loss cone instability of 50 eV-1 keV electrons in the lower half of harmonic bands in the low-density plasmasphere in event A, and 1-10 keV electrons in the upper half of harmonic bands in a relatively high-density region in event B. The current results successfully explain observations and provide a first direct evidence on how ECH waves are generated in the lower and upper half of harmonic frequency bands.

  9. Optimizing C4+ and C5+ beams of the Kei2 electron cyclotron resonance ion source using a special gas-mixing technique

    NARCIS (Netherlands)

    Drentje, A. G.; Muramatsu, M.; Kitagawa, A.

    With the prototype electron cyclotron resonance ion source for the next carbon therapy facility in Japan a series of measurements has been performed in order (a) to find the best condition for producing high beam currents of C4+ ions, and (b) to study the effect of "special" gas mixing by using a

  10. Plasma response measurements of external magnetic perturbations using electron cyclotron emission and comparisons to 3D ideal MHD equilibrium

    CERN Document Server

    Willensdorfer, M; Strumberger, E; Suttrop, W; Vanovac, B; Brida, D; Cavedon, M; Classen, I; Dunne, M; Fietz, S; Fischer, R; Kirk, A; Laggner, F M; Liu, Y Q; Odstrcil, T; Ryan, D A; Viezzer, E; Zohm, H; Luhmann, I C

    2016-01-01

    The plasma response from an external n = 2 magnetic perturbation field in ASDEX Upgrade has been measured using mainly electron cyclotron emission (ECE) diagnostics and a rigid rotating field. To interpret ECE and ECE-imaging (ECE-I) measurements accurately, forward modeling of the radiation transport has been combined with ray tracing. The measured data is compared to synthetic ECE data generated from a 3D ideal magnetohydrodynamics (MHD) equilibrium calculated by VMEC. The measured amplitudes of the helical displacement in the midplane are in reasonable agreement with the one from the synthetic VMEC diagnostics. Both exceed the vacuum field calculations and indicate the presence of an amplified kink response at the edge. Although the calculated magnetic structure of this edge kink peaks at poloidal mode numbers larger than the resonant components |m| > |nq|, the displacement measured by ECE-I is almost resonant |m| ~ |nq|. This is expected from ideal MHD in the proximity of rational surfaces. VMEC and MARS-...

  11. Fully non-inductive second harmonic electron cyclotron plasma ramp-up in the QUEST spherical tokamak

    Science.gov (United States)

    Idei, H.; Kariya, T.; Imai, T.; Mishra, K.; Onchi, T.; Watanabe, O.; Zushi, H.; Hanada, K.; Qian, J.; Ejiri, A.; Alam, M. M.; Nakamura, K.; Fujisawa, A.; Nagashima, Y.; Hasegawa, M.; Matsuoka, K.; Fukuyama, A.; Kubo, S.; Shimozuma, T.; Yoshikawa, M.; Sakamoto, M.; Kawasaki, S.; Nakashima, H.; Higashijima, A.; Ide, S.; Maekawa, T.; Takase, Y.; Toi, K.

    2017-12-01

    Fully non-inductive second (2nd) harmonic electron cyclotron (EC) plasma current ramp-up was demonstrated with a newlly developed 28 GHz system in the QUEST spherical tokamak. A high plasma current of 54 kA was non-inductively ramped up and sustained stably for 0.9 s with a 270 kW 28 GHz wave. A higher plasma current of 66 kA was also non-inductively achieved with a slow ramp-up of the vertical field. We have achieved a significantly higher plasma current than those achieved previously with the 2nd harmonic EC waves. This fully non-inductive 2nd harmonic EC plasma ramp-up method might be useful for future burning plasma devices and fusion reactors, in particular for operations at half magnetic field with the same EC heating equipment.

  12. submitter Beam experiments with the Grenoble test electron cyclotron resonance ion source at iThemba LABS

    CERN Document Server

    Thomae, R; Fourie, D; Mira, J; Nemulodi, F; Kuechler, D; Toivanen, V

    2016-01-01

    ABSTRACT At iThemba Laboratory for Accelerator Based Sciences (iThemba LABS) an electron cyclotron ion source was installed and commissioned. This source is a copy of the Grenoble Test Source (GTS) for the production of highly charged ions. The source is similar to the GTS-LHC at CERN and named GTS2. A collaboration between the Accelerators and Beam Physics Group of CERN and the Accelerator and Engineering Department of iThemba LABS was proposed in which the development of high intensity argon and xenon beams is envisaged. In this paper, we present beam experiments with the GTS2 at iThemba LABS, in which the results of continuous wave and afterglow operation of xenon ion beams with oxygen as supporting gases are presented.

  13. Edge characteristics and global confinement of electron cyclotron resonance heated plasmas in the TJ-II Stellarator

    Energy Technology Data Exchange (ETDEWEB)

    Tabares, F.L.; Branas, B.; Garcia-Cortes, I.; Tafalla, D.; Estrada, T.; Tribaldos, V. [Laboratorio Nacional de Fusion por Confinamiento Magnetico, Asociacion EURATOM/CIEMAT, Madrid (Spain)

    2001-08-01

    The edge parameters of electron cyclotron resonance heated plasmas in the TJ-II stellarator are reported. Data from atomic beam diagnostics and electrical probes have been used for edge and scrape-off layer characterization. Scans in heating power and plasma density for H and He plasmas have been performed, for a given magnetic configuration. A linear increase of the diffusion coefficient at the last-closed magnetic surface with the ratio of injected power to plasma density and a similar value of that parameter for the two atomic species investigated were obtained. Global particle confinement times between 3 and 15 ms have been deduced, and transition to an enhanced confinement mode in H plasmas has been observed under some conditions. The role of high-energy particle losses, due to trapping into the relatively high magnetic ripple, in the global energy balance of TJ-II plasmas is addressed. (author)

  14. Sawtooth control using electron cyclotron current drive in the presence of energetic particles in high performance ASDEX Upgrade plasmas

    CERN Document Server

    Chapman, I T; Maraschek, M; McCarthy, P J; Tardini, G

    2013-01-01

    Sawtooth control using steerable electron cyclotron current drive (ECCD) has been demonstrated in ASDEX Upgrade plasmas with a significant population of energetic ions in the plasma core and long uncontrolled sawtooth periods. The sawtooth period is found to be minimised when the ECCD resonance is swept to just inside the q = 1 surface. By utilising ECCD inside q = 1 for sawtooth control, it is possible to avoid the triggering of neoclassical tearing modes, even at significnatly higher pressure than anticipated in the ITER baseline scenario. Operation at 25% higher normalised pressure has been achieved when only modest ECCD power is used for sawtooth control compared to identical discharges without sawtooth control when neo-classical tearing modes are triggered by the sawteeth. Modelling suggests that the destabilisation arising from the change in the local magnetic shear caused by the ECCD is able to compete with the stabilising influence of the energetic particles inside the q = 1 surface.

  15. Studies of the beam extraction system of the GTS-LHC electron cyclotron resonance ion source at CERN.

    Science.gov (United States)

    Toivanen, V; Küchler, D

    2016-02-01

    The 14.5 GHz GTS-LHC Electron Cyclotron Resonance Ion Source (ECRIS) provides multiply charged heavy ion beams for the CERN experimental program. The GTS-LHC beam formation has been studied extensively with lead, argon, and xenon beams with varied beam extraction conditions using the ion optical code IBSimu. The simulation model predicts self-consistently the formation of triangular and hollow beam structures which are often associated with ECRIS ion beams, as well as beam loss patterns which match the observed beam induced markings in the extraction region. These studies provide a better understanding of the properties of the extracted beams and a way to diagnose the extraction system performance and limitations, which is otherwise challenging due to the lack of direct diagnostics in this region and the limited availability of the ion source for development work.

  16. Design and characterization of a 32-channel heterodyne radiometer for electron cyclotron emission measurements on experimental advanced superconducting tokamak.

    Science.gov (United States)

    Han, X; Liu, X; Liu, Y; Domier, C W; Luhmann, N C; Li, E Z; Hu, L Q; Gao, X

    2014-07-01

    A 32-channel heterodyne radiometer has been developed for the measurement of electron cyclotron emission (ECE) on the experimental advanced superconducting tokamak (EAST). This system collects X-mode ECE radiation spanning a frequency range of 104-168 GHz, where the frequency coverage corresponds to a full radial coverage for the case with a toroidal magnetic field of 2.3 T. The frequency range is equally spaced every 2 GHz from 105.1 to 167.1 GHz with an RF bandwidth of ~500 MHz and the video bandwidth can be switched among 50, 100, 200, and 400 kHz. Design objectives and characterization of the system are presented in this paper. Preliminary results for plasma operation are also presented.

  17. The effect of gas mixing and biased disc voltage on the preglow transient of electron cyclotron resonance ion source.

    Science.gov (United States)

    Tarvainen, O; Toivanen, V; Komppula, J; Kalvas, T; Koivisto, H

    2012-02-01

    The effect of gas mixing and biased disc voltage on the preglow of electron cyclotron resonance ion source plasma has been studied with the AECR-U type 14 GHz ion source. It was found that gas mixing has a significant effect on the preglow. The extracted transient beam currents and efficiency of the heavier species increase, while the currents and efficiency of the lighter species decrease when gas mixing is applied. The effect of the biased disc was found to be pronounced in continuous operation mode in comparison to preglow. The data provide information on the time scales of the plasma processes explaining the effects of gas mixing and biased disc. The results also have implications on production of radioactive ion beams in preglow mode for the proposed Beta Beam neutrino factory.

  18. Superconducting magnet performance for 28 GHz electron cyclotron resonance ion source developed at the Korea Basic Science Institute.

    Science.gov (United States)

    Park, Jin Yong; Choi, Seyong; Lee, Byoung-Seob; Yoon, Jang-Hee; Ok, Jung-Woo; Kim, Byoung Chul; Shin, Chang Seouk; Ahn, Jung Keun; Won, Mi-Sook

    2014-02-01

    A superconducting magnet for use in an electron cyclotron resonance ion source was developed at the Korea Basic Science Institute. The superconducting magnet is comprised of three solenoids and a hexapole magnet. According to the design value, the solenoid magnets can generate a mirror field, resulting in axial magnetic fields of 3.6 T at the injection area and 2.2 T at the extraction region. A radial field strength of 2.1 T can also be achieved by hexapole magnet on the plasma chamber wall. NbTi superconducting wire was used in the winding process following appropriate techniques for magnet structure. The final assembly of the each magnet involved it being vertically inserted into the cryostat to cool down the temperature using liquid helium. The performance of each solenoid and hexapole magnet was separately verified experimentally. The construction of the superconducting coil, the entire magnet assembly for performance testing and experimental results are reported herein.

  19. Fabrication of an optimized hexapole magnet for a 14.5 GHz electron cyclotron resonance ion source.

    Science.gov (United States)

    Oh, Byung-Hoon; Seo, Chang Seog; In, Sang-Ryul; Kim, Tae-Seong

    2010-02-01

    A hexapole magnet for a 14.5 GHz electron cyclotron resonance (ECR) ion source, where the maximum radial field on the wall of the plasma chamber is higher than 1.1 T, has been designed and fabricated. The size of the outer diameter and the number of the sector of the hexapole are optimized for a 14.5 GHz ECR ion source with the help of a three-dimensional field calculation code. Moreover, to make a strong and long-life magnet against the demagnetic field on the hexapole multilayered structure in radial and axial directions is considered in the design. The distributions of the demagnetic fields are estimated by the calculation of the radial field in a hexapole magnet and the axial field from the solenoid coils. Proper grades of magnetic materials depending on the strength of the demagnetic field are applied for the different layers. The magnetic fields of the measured and calculated ones have been compared.

  20. The preliminary tests of the superconducting electron cyclotron resonance ion source DECRIS-SC2.

    Science.gov (United States)

    Efremov, A; Bekhterev, V; Bogomolov, S; Drobin, V; Loginov, V; Lebedev, A; Yazvitsky, N; Yakovlev, B

    2012-02-01

    A new compact version of the "liquid He-free" superconducting ECR ion source, to be used as an injector of highly charged heavy ions for the MC-400 cyclotron, is designed and built at the Flerov Laboratory of Nuclear Reactions in collaboration with the Laboratory of High Energy Physics of JINR. The axial magnetic field of the source is created by the superconducting magnet and the NdFeB hexapole is used for the radial plasma confinement. The microwave frequency of 14 GHz is used for ECR plasma heating. During the first tests, the source shows a good enough performance for the production of medium charge state ions. In this paper, we will present the design parameters and the preliminary results with gaseous ions.

  1. Development of a compact thermal lithium atom beam source for measurements of electron velocity distribution function anisotropy in electron cyclotron resonance plasmas.

    Science.gov (United States)

    Nishioka, T; Shikama, T; Nagamizo, S; Fujii, K; Zushi, H; Uchida, M; Iwamae, A; Tanaka, H; Maekawa, T; Hasuo, M

    2013-07-01

    The anisotropy of the electron velocity distribution function (EVDF) in plasmas can be deduced from the polarization of emissions induced by anisotropic electron-impact excitation. In this paper, we develop a compact thermal lithium atom beam source for spatially resolved measurements of the EVDF anisotropy in electron cyclotron resonance (ECR) plasmas. The beam system is designed such that the ejected beam has a slab shape, and the beam direction is variable. The divergence and flux of the beam are evaluated by experiments and calculations. The developed beam system is installed in an ECR plasma device with a cusp magnetic field, and the LiI 2s-2p emission (670.8 nm) is observed in low-pressure helium plasma. The two-dimensional distributions of the degree and direction of the polarization in the LiI emission are measured by a polarization imaging system. The evaluated polarization distribution suggests the spatial variation of the EVDF anisotropy.

  2. Efficiency enhancement of slow-wave electron-cyclotron maser by a second-order shaping of the magnetic field in the low-gain limit

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Si-Jia; Zhang, Yu-Fei; Wang, Kang [School of Science, Beijing University of Chemical Technology, Beijing 100029 (China); Li, Yong-Ming [Information Science and Engineering College, XinJiang University, Urumqi XinJiang 830046 (China); Jing, Jian, E-mail: jingjian@mail.buct.edu.cn [School of Science, Beijing University of Chemical Technology, Beijing 100029 (China)

    2017-03-15

    Based on the anomalous Doppler effect, we put forward a proposal to enhance the conversion efficiency of the slow-wave electron cyclotron masers (ECM) under the resonance condition. Compared with previous studies, we add a second-order shaping term in the guild magnetic field. Theoretical analyses and numerical calculations show that it can enhance the conversion efficiency in the low-gain limit. The case of the initial velocity spread of electrons satisfying the Gaussian distribution is also analysed numerically.

  3. Time evolution of endpoint energy of Bremsstrahlung spectra and ion production from an electron cyclotron resonance ion source

    Energy Technology Data Exchange (ETDEWEB)

    Tarvainen, Ollie [Los Alamos National Laboratory; Ropponen, Tommi [JYFL; Jones, Peter [JYFL; Kalvas, Taneli [JYFL

    2008-01-01

    Electron cyclotron resonance ion sources (ECRIS) are used to produce high charge state heavy ion beams for the use of nuclear and materials science, for instance. The most powerful ECR ion sources today are superconducting. One of the problems with superconducting ECR ion sources is the use of high radio frequency (RF) power which results in bremsstrahlung radiation adding an extra heat load to the cryostat. In order to understand the electron heating process and timescales in the ECR plasma, time evolution measurement of ECR bremsstrahlung was carried out. In the measurements JYFL 14 GHz ECRIS was operated in a pulsed mode and bremsstrahlung data from several hundred RF pulses was recorded. Time evolution of ion production was also studied and compared to one of the electron heating theories. To analyze the measurement data at C++ program was developed. Endpoint energies of the bremsstrahlung spectra as a function of axial magnetic field strength, pressure and RF power are presented and ion production timescales obtained from the measurements are compared to bremsstrahlung emission timescales and one of the stochastic heating theories.

  4. Low-noise AlGaAs/InGaAs/GaAs pseudomorphic high electron mobility transistor recessed by electron cyclotron resonance plasma etching

    CERN Document Server

    Lee, J H; Lee, C W; Yoon, H S; Park, B S; Park, C S

    1999-01-01

    GaAs pseudomorphic high electron mobility transistor recessed by electron cyclotron resonance (ECR) plasma etching have been investigated. We used a BCl sub 3 /SF sub 6 gas mixture to implement the gate recess process. We obtained a uniformity of the threshold voltage to within 50 mV in 3-inch wafers. The GaAs PHEMTs with a 0.2-mu m gate length recessed by the ECR plasma exhibited a minimum noise figure (NF sub m sub i sub n) as low as 0.26 dB with an associated gain (G sub a) of 13 dB at 12 GHz. At 18 GHz, the NF sub m sub i sub n was 0.47 dB with a Ga of 11.66 dB. These results suggest that the ECR plasma etching process reported here is suitable as a manufacturing process for gate recess of a GaAs PHEMT.

  5. The effect of electron cyclotron heating on density fluctuations at ion and electron scales in ITER baseline scenario discharges on the DIII-D tokamak

    Science.gov (United States)

    Marinoni, A.; Pinsker, R. I.; Porkolab, M.; Rost, J. C.; Davis, E. M.; Burrell, K. H.; Candy, J.; Staebler, G. M.; Grierson, B. A.; McKee, G. R.; Rhodes, T. L.; The DIII-D Team

    2017-12-01

    Experiments simulating the ITER baseline scenario on the DIII-D tokamak show that torque-free pure electron heating, when coupled to plasmas subject to a net co-current beam torque, affects density fluctuations at electron scales on a sub-confinement time scale, whereas fluctuations at ion scales change only after profiles have evolved to a new stationary state. Modifications to the density fluctuations measured by the phase contrast imaging diagnostic (PCI) are assessed by analyzing the time evolution following the switch-off of electron cyclotron heating (ECH), thus going from mixed beam/ECH to pure neutral beam heating at fixed βN . Within 20 ms after turning off ECH, the intensity of fluctuations is observed to increase at frequencies higher than 200 kHz in contrast, fluctuations at lower frequency are seen to decrease in intensity on a longer time scale, after other equilibrium quantities have evolved. Non-linear gyro-kinetic modeling at ion and electron scales scales suggest that, while the low frequency response of the diagnostic is consistent with the dominant ITG modes being weakened by the slow-time increase in flow shear, the high frequency response is due to prompt changes to the electron temperature profile that enhance electron modes and generate a larger heat flux and an inward particle pinch. These results suggest that electron heated regimes in ITER will feature multi-scale fluctuations that might affect fusion performance via modifications to profiles.

  6. Electrostatic ion cyclotron waves in a plasma with an ion beam and counterstreaming bulk electrons - Waves in the zero-frequency band. [in aurora

    Science.gov (United States)

    Singh, N.; Conrad, J. R.; Schunk, R. W.

    1985-01-01

    A common feature of the auroral plasma in the region above field-aligned (parallel) potential drops are electrostatic hydrogen cyclotron (EHC) waves. The present paper has the objective to show that wave excitation in the zero-frequency band can occur when the ion beams and the current-carrying bulk electrons counterstream. The instability mechanism involves the Landau interaction of the slow (negative energy) ion-beam-cyclotron waves with the drifting electrons and also with the target (background) ions. Only the latter resonant interaction between the beam and the target ions was considered by Okuda and Nishikawa (1984). In this study, it is shown that an electron drift makes an additional unstable contribution to the waves in the zero-frequency band, including those discussed by Okuda and Nishikawa.

  7. A mode converter to generate a Gaussian-like mode for injection into the VENUS electron cyclotron resonance ion source

    Energy Technology Data Exchange (ETDEWEB)

    Lyneis, C., E-mail: CMLyneis@lbl.gov; Benitez, J.; Hodgkinson, A.; Strohmeier, M.; Todd, D. [Nuclear Science Division, Lawrence Berkeley National Laboratory, Berkeley, California 94720 (United States); Plaum, B. [Institut für Grenzflächenverfahrenstechnik und Plasmatechnologie (IGVP), Stuttgart (Germany); Thuillier, T. [Laboratoire de Physique Subatomique et de Cosmologie, Université Joseph Fourier Grenoble 1, CNRS/IN2P3, Institut Polytechnique de Grenoble, 53 rue des martyrs 38026 Grenoble cedex (France)

    2014-02-15

    A number of superconducting electron cyclotron resonance (ECR) ion sources use gyrotrons at either 24 or 28 GHz for ECR heating. In these systems, the microwave power is launched into the plasma using the TE{sub 01} circular waveguide mode. This is fundamentally different and may be less efficient than the typical rectangular, linearly polarized TE{sub 10} mode used for launching waves at lower frequencies. To improve the 28 GHz microwave coupling in VENUS, a TE{sub 01}-HE{sub 11} mode conversion system has been built to test launching HE{sub 11} microwave power into the plasma chamber. The HE{sub 11} mode is a quasi-Gaussian, linearly polarized mode, which should couple strongly to the plasma electrons. The mode conversion is done in two steps. First, a 0.66 m long “snake” converts the TE{sub 01} mode to the TE{sub 11} mode. Second, a corrugated circular waveguide excites the HE{sub 11} mode, which is launched directly into the plasma chamber. The design concept draws on the development of similar devices used in tokamaks and stellerators. The first tests of the new coupling system are described below.

  8. Pre- and post-irradiation studies on mm-wave losses in reference window materials for electron cyclotron wave systems

    Energy Technology Data Exchange (ETDEWEB)

    Heidinger, R. [Forschungszentrum Karlsruhe GmbH Technik und Umwelt (Germany). Inst. fuer Materialforschung; Ibarra, A.; Molla, J. [CIEMAT, Association CIEMAT-Euratom, Inst. Investigacion Basica, Madrid (Spain)

    1998-10-01

    Dielectric materials for transmission windows in electron cyclotron (EC) wave systems are studied for the radiation effects on their dielectric properties (permittivity, loss tangent). Based on comparative neutron irradiation experiments performed at cryogenic and reactor pool temperatures, it is shown here that fast neutron fluences up to at least (2-4) x 10{sup 20} n/m{sup 2} (E > 0.1 MeV) do not critically affect the mm-wave losses in HEMEX grade sapphire, the reference material for the cryogenically cooled high power EC window. Fast neutron (10{sup 20} n/m{sup 2}) and electron (5 x 10{sup -6} dpa) irradiations on specially developed CVD diamond grades for conventionally cooled windows demonstrate acceptable mm-wave loss levels, whereas loss at lower frequencies can be significantly affected. In-beam measurements under X-ray irradiation show no additional loss terms in sapphire and CVD diamond, at least up to 0.45 Gy/s. Dielectric data obtained for synthetic quartz indicate that the observed changes due to neutron damage are not severe for fast neutron fluences at least up to 10{sup 22} n/m{sup 2}. (orig.) 16 refs.

  9. A mode converter to generate a Gaussian-like mode for injection into the VENUS electron cyclotron resonance ion source.

    Science.gov (United States)

    Lyneis, C; Benitez, J; Hodgkinson, A; Plaum, B; Strohmeier, M; Thuillier, T; Todd, D

    2014-02-01

    A number of superconducting electron cyclotron resonance (ECR) ion sources use gyrotrons at either 24 or 28 GHz for ECR heating. In these systems, the microwave power is launched into the plasma using the TE01 circular waveguide mode. This is fundamentally different and may be less efficient than the typical rectangular, linearly polarized TE10 mode used for launching waves at lower frequencies. To improve the 28 GHz microwave coupling in VENUS, a TE01-HE11 mode conversion system has been built to test launching HE11 microwave power into the plasma chamber. The HE11 mode is a quasi-Gaussian, linearly polarized mode, which should couple strongly to the plasma electrons. The mode conversion is done in two steps. First, a 0.66 m long "snake" converts the TE01 mode to the TE11 mode. Second, a corrugated circular waveguide excites the HE11 mode, which is launched directly into the plasma chamber. The design concept draws on the development of similar devices used in tokamaks and stellerators. The first tests of the new coupling system are described below.

  10. 3D Printing for the Rapid Prototyping of Structural Electronics

    National Research Council Canada - National Science Library

    Macdonald, Eric; Salas, Rudy; Espalin, David; Perez, Mireya; Aguilera, Efrain; Muse, Dan; Wicker, Ryan B

    2014-01-01

    .... The use of advanced 3D printing technology enhanced with component placement and electrical interconnect deposition can provide electronic prototypes that now can be rapidly fabricated in comparable...

  11. Whistler-cyclotron spontaneous fluctuations as a proxy to identify thermal and non-thermal electrons in the solar wind

    Science.gov (United States)

    Moya, P. S.; Vinas, A. F.; Navarro, R.; Araneda, J. A.

    2014-12-01

    Observed electron velocity distributions in the solar wind exhibit a variety of non-thermal features which deviate from thermal equilibrium, in the form of temperature anisotropies, suprathermal tails, and field aligned beams. The state close to thermal equilibrium and its departure from it provides a source for spontaneous emissions of electromagnetic fluctuations as for example the whistler cyclotron waves at electron scales. Here we present a comparative analysis of these fluctuations based upon anisotropic plasma modeled with thermal and non-thermal particle distributions. The analysis presented here considers the second-order theory of fluctuations and the dispersion relation of weakly transverse fluctuations, with wave vectors parallel to the uniform background magnetic field, in a finite temperature isotropic thermal bi-Maxwellian and non-thermal Tsallis-kappa-like magnetized electron-proton plasma. Dispersion analysis and stability thresholds are derived for these non-thermal distributions and compared with similar results obtained from PIC simulations using plasma and field parameters relevant to the solar wind environments. Our results indicate that there is a strong dependence between the shape of the velocity distribution function and the topological regions in the frequency-wave number plane in which the spontaneous fluctuations emerge. In the case of non-thermal plasmas there is an enhancement of the fluctuations level due to the effective higher-temperature effects and the excess of suprathermal particles. This feature may be used proxy to identify the nature of electron populations in space plasmas when high resolution particle instruments are not available.

  12. Two-stream instabilities from the lower-hybrid frequency to the electron cyclotron frequency: application to the front of quasi-perpendicular shocks

    Directory of Open Access Journals (Sweden)

    L. Muschietti

    2017-09-01

    Full Text Available Quasi-perpendicular supercritical shocks are characterized by the presence of a magnetic foot due to the accumulation of a fraction of the incoming ions that is reflected by the shock front. There, three different plasma populations coexist (incoming ion core, reflected ion beam, electrons and can excite various two-stream instabilities (TSIs owing to their relative drifts. These instabilities represent local sources of turbulence with a wide frequency range extending from the lower hybrid to the electron cyclotron. Their linear features are analyzed by means of both a dispersion study and numerical PIC simulations. Three main types of TSI and correspondingly excited waves are identified: i. Oblique whistlers due to the (so-called fast relative drift between reflected ions/electrons; the waves propagate toward upstream away from the shock front at a strongly oblique angle (θ ∼ 50° to the ambient magnetic field Bo, have frequencies a few times the lower hybrid, and have wavelengths a fraction of the ion inertia length c∕ωpi. ii. Quasi-perpendicular whistlers due to the (so-called slow relative drift between incoming ions/electrons; the waves propagate toward the shock ramp at an angle θ a few degrees off 90°, have frequencies around the lower hybrid, and have wavelengths several times the electron inertia length c∕ωpe. iii. Extended Bernstein waves which also propagate in the quasi-perpendicular domain, yet are due to the (so-called fast relative drift between reflected ions/electrons; the instability is an extension of the electron cyclotron drift instability (normally strictly perpendicular and electrostatic and produces waves with a magnetic component which have frequencies close to the electron cyclotron as well as wavelengths close to the electron gyroradius and which propagate toward upstream. Present results are compared with previous works in order to stress some features not previously analyzed and to define a more

  13. Two-stream instabilities from the lower-hybrid frequency to the electron cyclotron frequency: application to the front of quasi-perpendicular shocks

    Science.gov (United States)

    Muschietti, Laurent; Lembège, Bertrand

    2017-09-01

    Quasi-perpendicular supercritical shocks are characterized by the presence of a magnetic foot due to the accumulation of a fraction of the incoming ions that is reflected by the shock front. There, three different plasma populations coexist (incoming ion core, reflected ion beam, electrons) and can excite various two-stream instabilities (TSIs) owing to their relative drifts. These instabilities represent local sources of turbulence with a wide frequency range extending from the lower hybrid to the electron cyclotron. Their linear features are analyzed by means of both a dispersion study and numerical PIC simulations. Three main types of TSI and correspondingly excited waves are identified: i. Oblique whistlers due to the (so-called fast) relative drift between reflected ions/electrons; the waves propagate toward upstream away from the shock front at a strongly oblique angle (θ ˜ 50°) to the ambient magnetic field Bo, have frequencies a few times the lower hybrid, and have wavelengths a fraction of the ion inertia length c/ωpi. ii. Quasi-perpendicular whistlers due to the (so-called slow) relative drift between incoming ions/electrons; the waves propagate toward the shock ramp at an angle θ a few degrees off 90°, have frequencies around the lower hybrid, and have wavelengths several times the electron inertia length c/ωpe. iii. Extended Bernstein waves which also propagate in the quasi-perpendicular domain, yet are due to the (so-called fast) relative drift between reflected ions/electrons; the instability is an extension of the electron cyclotron drift instability (normally strictly perpendicular and electrostatic) and produces waves with a magnetic component which have frequencies close to the electron cyclotron as well as wavelengths close to the electron gyroradius and which propagate toward upstream. Present results are compared with previous works in order to stress some features not previously analyzed and to define a more synthetic view of these TSIs.

  14. Generation of high charge state metal ion beams by electron cyclotron resonance heating of vacuum arc plasma in cusp trap.

    Science.gov (United States)

    Nikolaev, A G; Savkin, K P; Oks, E M; Vizir, A V; Yushkov, G Yu; Vodopyanov, A V; Izotov, I V; Mansfeld, D A

    2012-02-01

    A method for generating high charge state heavy metal ion beams based on high power microwave heating of vacuum arc plasma confined in a magnetic trap under electron cyclotron resonance conditions has been developed. A feature of the work described here is the use of a cusp magnetic field with inherent "minimum-B" structure as the confinement geometry, as opposed to a simple mirror device as we have reported on previously. The cusp configuration has been successfully used for microwave heating of gas discharge plasma and extraction from the plasma of highly charged, high current, gaseous ion beams. Now we use the trap for heavy metal ion beam generation. Two different approaches were used for injecting the vacuum arc metal plasma into the trap--axial injection from a miniature arc source located on-axis near the microwave window, and radial injection from sources mounted radially at the midplane of the trap. Here, we describe preliminary results of heating vacuum arc plasma in a cusp magnetic trap by pulsed (400 μs) high power (up to 100 kW) microwave radiation at 37.5 GHz for the generation of highly charged heavy metal ion beams.

  15. Statistical Study of the Occurrence of POES Relativistic Electron Precipitation (REP) in Correlation with Electromagnetic Ion Cyclotron (EMIC) Waves

    Science.gov (United States)

    Hembeck, J.; Lessard, M.; Engebretson, M. J.; Rodger, C. J.; Hendry, A.

    2016-12-01

    Electromagnetic Ion Cyclotron (EMIC) waves are phenomena that exist within the Earth's magnetosphere caused by an ion temperature anisotropy. The ideal conditions for EMIC wave growth occur during solar storms. In this statistical study, Polar Orbiting Environmental Satellites (POES) relativistic electron precipitation (REP) data are compared to EMIC wave data from Halley Bay in the years ranging from 2008-2010. This statistical study considers a specific type of EMIC wave events known as Intervals of Pulsations of Diminishing Periods (IPDP) to see whether this type of EMIC wave causes a statistically greater occurrence of REP. In this study, different types of IPDP are characterized based on the increase in frequency over time of each wave form. Another considered characteristic of the IPDP waves is whether the wave is continuous or appears as discrete packets, which may actually be separate events. IPDP events are cataloged and then compared to REP events from the POES data set, forming a study that is complementary to that of Hendry et al. [2016], who compared REP from POES data to the presence of EMIC waves at Halley Bay.

  16. Development of a high power wideband polarizer for electron cyclotron current drive system in JT-60SA

    Energy Technology Data Exchange (ETDEWEB)

    Saigusa, Mikio, E-mail: saigusa@mx.ibaraki.ac.jp [Ibaraki University, Hitachi, Ibaraki 316-8511 (Japan); Oyama, Gaku; Matsubara, Fumiaki; Takii, Keita; Sai, Takuma [Ibaraki University, Hitachi, Ibaraki 316-8511 (Japan); Kobayashi, Takayuki; Moriyama, Shinichi [Japan Atomic Energy Agency, Naka, Ibaraki 311-0193 (Japan)

    2015-10-15

    Highlights: • We developed a new wideband polarizer for JT-60SA ECCD system. • The wideband polarizer is optimized for dual frequency gyrotrons (110 and 138 GHz) in JT-60SA. • The wideband polarization properties were verified at cold tests. • The preliminary high power tests have been carried out at 0.25 MW, 3 s at 110 GHz. - Abstract: A wideband polarizer consisting of a polarization twister and a circular polarizer has been developed for an electron cyclotron current driving system in JT-60SA, where the output frequencies of a dual frequency gyrotron for JT-60SA are 110 and 138 GHz. The groove depths are optimized for the dual frequencies by numerical simulations using a FDTD method and cold test results. The polarization properties of a mock-up polarizer are measured at the dual frequencies in cold tests. The cold test results suggest that all practical polarizations for ECCD experiments can be achieved at the dual frequencies. The prototype polarization twister has been tested up to 0.25 MW during 3 s at the frequency of 110 GHz.

  17. Diagnostics of a charge breeder electron cyclotron resonance ion source helium plasma with the injection of ^{23}Na^{1+} ions

    Directory of Open Access Journals (Sweden)

    O. Tarvainen

    2016-05-01

    Full Text Available This work describes the utilization of an injected ^{23}Na^{1+} ion beam as a diagnostics of the helium plasma of a charge breeder electron cyclotron resonance ion source. The obtained data allows estimating the upper limit for the ion-ion collision mean-free path of the incident sodium ions, the lower limit of ion-ion collision frequencies for all charge states of the sodium ions and the lower limit of the helium plasma density. The ion-ion collision frequencies of high charge state ions are shown to be at least on the order of 1–10 MHz and the plasma density is estimated to be on the order of 10^{11}  cm^{-3} or higher. The experimental results are compared to simulations of the ^{23}Na^{1+} capture into the helium plasma. The results indicate that the lower breeding efficiency of light ions in comparison to heavier elements is probably due to different capture efficiencies in which the in-flight ionization of the incident 1+ ions plays a vital role.

  18. Upgrade of the beam extraction system of the GTS-LHC electron cyclotron resonance ion source at CERN.

    Science.gov (United States)

    Toivanen, V; Bellodi, G; Dimov, V; Küchler, D; Lombardi, A M; Maintrot, M

    2016-02-01

    Linac3 is the first accelerator in the heavy ion injector chain of the Large Hadron Collider (LHC), providing multiply charged heavy ion beams for the CERN experimental program. The ion beams are produced with GTS-LHC, a 14.5 GHz electron cyclotron resonance ion source, operated in afterglow mode. Improvement of the GTS-LHC beam formation and beam transport along Linac3 is part of the upgrade program of the injector chain in preparation for the future high luminosity LHC. A mismatch between the ion beam properties in the ion source extraction region and the acceptance of the following Low Energy Beam Transport (LEBT) section has been identified as one of the factors limiting the Linac3 performance. The installation of a new focusing element, an einzel lens, into the GTS-LHC extraction region is foreseen as a part of the Linac3 upgrade, as well as a redesign of the first section of the LEBT. Details of the upgrade and results of a beam dynamics study of the extraction region and LEBT modifications will be presented.

  19. Effect of double frequency heating on the lead afterglow beam currents of an electron cyclotron resonance ion source

    Science.gov (United States)

    Toivanen, V.; Bellodi, G.; Küchler, D.; Wenander, F.; Tarvainen, O.

    2017-10-01

    The effect of double frequency heating on the performance of the CERN GTS-LHC 14.5 GHz Electron Cyclotron Resonance (ECR) ion source in afterglow mode is reported. The source of the secondary microwave frequency was operated both in pulsed and continuous wave (CW) modes within the range of 12-18 GHz. The results demonstrate that the addition of the secondary frequency can significantly impact the extracted beam currents and the temporal stability of the beam during the afterglow discharge. For example, up to a factor of 2.6 increase was achieved for 208Pb 35 and a factor of 3.1 for 208Pb 37+ compared to single frequency afterglow currents. It is shown that these effects are dependent on the choice of the secondary frequency with respect to the primary one and on the temporal synchronization between the two microwave sources. Overall, the results provide new insight into the afterglow discharge supporting the prevailing understanding of the physical processes behind the phenomenon.

  20. Carbon beam extraction with 14.5 GHz electron cyclotron resonance ion source at Korea Atomic Energy Research Institute.

    Science.gov (United States)

    Lee, Cheol Ho; Oh, Byung-Hoon; Chang, Dae-Sik; Jeong, Sun-Chan

    2014-02-01

    A 14.5 GHz Electron Cyclotron Resonance ion source (ECRIS) has been made to produce C(4+) beam for using a carbon therapy facility and recently tested at KAERI. Highly charged carbon ions have been successfully extracted. When using only CO2 gas, the beam current of C(4+) was almost 14 μA at 15 kV extraction voltage. To get higher current of the C(4+) beam, while optimizing confinement magnetic field configuration (e.g., axial strengths at minimum and extraction side), gas-mixing (CO2/He), and biased disk were introduced. When the gas mixing ratio of the CO2/He gas is 1:8 at an operational pressure of 5 × 10(-7) mbar and the disk was biased to -150 V relative to the ion source body, the highest current of the C(4+) beam was achieved to be 50 μA, more than three times higher than previously observed only with CO2 gas. Some details on the operating conditions of the ECRIS were discussed.

  1. Relativistic down-shift frequency effect on the application of electron cyclotron emission measurements to JT-60U tokamak plasmas. Second harmonics

    Energy Technology Data Exchange (ETDEWEB)

    Sato, Masayasu; Isei, Nobuaki; Ishida, Sinichi [Japan Atomic Energy Research Inst., Naka, Ibaraki (Japan). Naka Fusion Research Establishment

    1995-11-01

    Effect of relativistic frequency down-shift on the determination of the electron temperature profile from electron cyclotron emission(ECE) in JT-60U tokamak plasmas is studied. The radial shift of the electron temperature profile due to the effects is not negligible, compared with the spatial resolution of ECE measurement systems of JT-60U. Therefore it is necessary to correct the effect for precise measurement of the electron temperature profile. Dependencies of the shifted frequency on the electron density, electron temperature and toroidal magnetic field are studied for the uniform electron density and parabolic electron temperature profile in JT-60U. It is revealed to be necessary for the estimation of shift due to the relativistic down-shift frequency to take into account of the optical thickness. (author).

  2. Spatial distribution of charged particles along the ion-optical axis in electron cyclotron resonance ion sources. Experimental results

    Energy Technology Data Exchange (ETDEWEB)

    Panitzsch, Lauri

    2013-02-08

    The experimental determination of the spatial distribution of charged particles along the ion-optical axis in electron cyclotron resonance ion sources (ECRIS) defines the focus of this thesis. The spatial distributions of different ion species were obtained in the object plane of the bending magnet ({approx}45 cm downstream from the plasma electrode) and in the plane of the plasma electrode itself, both in high spatial resolution. The results show that each of the different ion species forms a bloated, triangular structure in the aperture of the plasma electrode. The geometry and the orientation of these structures are defined by the superposition of the radial and axial magnetic fields. The radial extent of each structure is defined by the charge of the ion. Higher charge states occupy smaller, more concentrated structures. The total current density increases towards the center of the plasma electrode. The circular and star-like structures that can be observed in the beam profiles of strongly focused, extracted ion beams are each dominated by ions of a single charge state. In addition, the spatially resolved current density distribution of charged particles in the plasma chamber that impinge on the plasma electrode was determined, differentiating between ions and electrons. The experimental results of this work show that the electrons of the plasma are strongly connected to the magnetic field lines in the source and thus spatially well confined in a triangular-like structure. The intensity of the electrons increases towards the center of the plasma electrode and the plasma chamber, as well. These electrons are surrounded by a spatially far less confined and less intense ion population. All the findings mentioned above were already predicted in parts by simulations of different groups. However, the results presented within this thesis represent the first (and by now only) direct experimental verification of those predictions and are qualitatively transferable to

  3. A double-layer based model of ion confinement in electron cyclotron resonance ion source

    Science.gov (United States)

    Mascali, D.; Neri, L.; Celona, L.; Castro, G.; Torrisi, G.; Gammino, S.; Sorbello, G.; Ciavola, G.

    2014-02-01

    The paper proposes a new model of ion confinement in ECRIS, which can be easily generalized to any magnetic configuration characterized by closed magnetic surfaces. Traditionally, ion confinement in B-min configurations is ascribed to a negative potential dip due to superhot electrons, adiabatically confined by the magneto-static field. However, kinetic simulations including RF heating affected by cavity modes structures indicate that high energy electrons populate just a thin slab overlapping the ECR layer, while their density drops down of more than one order of magnitude outside. Ions, instead, diffuse across the electron layer due to their high collisionality. This is the proper physical condition to establish a double-layer (DL) configuration which self-consistently originates a potential barrier; this "barrier" confines the ions inside the plasma core surrounded by the ECR surface. The paper will describe a simplified ion confinement model based on plasma density non-homogeneity and DL formation.

  4. A double-layer based model of ion confinement in electron cyclotron resonance ion source

    Energy Technology Data Exchange (ETDEWEB)

    Mascali, D., E-mail: davidmascali@lns.infn.it; Neri, L.; Celona, L.; Castro, G.; Gammino, S.; Ciavola, G. [Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali del Sud, via S. Sofia 62, 95123 Catania (Italy); Torrisi, G. [Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali del Sud, via S. Sofia 62, 95123 Catania (Italy); Università Mediterranea di Reggio Calabria, Dipartimento di Ingegneria dell’Informazione, delle Infrastrutture e dell’Energia Sostenibile, Via Graziella, I-89100 Reggio Calabria (Italy); Sorbello, G. [Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali del Sud, via S. Sofia 62, 95123 Catania (Italy); Università degli Studi di Catania, Dipartimento di Ingegneria Elettrica Elettronica ed Informatica, Viale Andrea Doria 6, 95125 Catania (Italy)

    2014-02-15

    The paper proposes a new model of ion confinement in ECRIS, which can be easily generalized to any magnetic configuration characterized by closed magnetic surfaces. Traditionally, ion confinement in B-min configurations is ascribed to a negative potential dip due to superhot electrons, adiabatically confined by the magneto-static field. However, kinetic simulations including RF heating affected by cavity modes structures indicate that high energy electrons populate just a thin slab overlapping the ECR layer, while their density drops down of more than one order of magnitude outside. Ions, instead, diffuse across the electron layer due to their high collisionality. This is the proper physical condition to establish a double-layer (DL) configuration which self-consistently originates a potential barrier; this “barrier” confines the ions inside the plasma core surrounded by the ECR surface. The paper will describe a simplified ion confinement model based on plasma density non-homogeneity and DL formation.

  5. Electron cyclotron waves transmission: new approach for the characterization of electron distribution functions in Tokamak hot plasmas; La transmission d`ondes cyclotroniques electroniques: une approche nouvelle pour caracteriser les fonctions de distribution electronique des plasmas chauds de Tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Michelot, Y.

    1995-10-01

    Fast electrons are one of the basic ingredients of plasma operations in many existing thermonuclear fusion research devices. However, the understanding of fast electrons dynamics during creation and sustainment of the superthermal electrons tail is far for being satisfactory. For this reason, the Electron Cyclotron Transmission (ECT) diagnostic was implemented on Tore Supra tokamak. It consists on a microwave transmission system installed on a vertical chord crossing the plasma center and working in the frequency range 77-109 GHz. Variations of the wave amplitude during the propagation across the plasma may be due to refraction and resonant absorption. For the ECT, the most common manifestation of refraction is a reduction of the received power density with respect to the signal detected in vacuum, due to the spreading and deflection of the wave beam. Wave absorption is observed in the vicinity of the electron cyclotron harmonics and may be due both to thermal plasma and to superthermal electron tails. It has a characteristic frequency dependence due to the relativistic mass variation in the wave-electron resonance condition. This thesis presents the first measurements of: the extraordinary mode optical depth at the third harmonics, the electron temperature from the width of a cyclotron absorption line and the relaxation times of the electron distribution during lower hybrid current drive from the ordinary mode spectral superthermal absorption line at the first harmonic. (J.S.). 175 refs., 110 figs., 9 tabs., 3 annexes.

  6. High electronegativity multi-dipolar electron cyclotron resonance plasma source for etching by negative ions

    DEFF Research Database (Denmark)

    Stamate, Eugen; Draghici, M.

    2012-01-01

    A large area plasma source based on 12 multi-dipolar ECR plasma cells arranged in a 3 x 4 matrix configuration was built and optimized for silicon etching by negative ions. The density ratio of negative ions to electrons has exceeded 300 in Ar/SF6 gas mixture when a magnetic filter was used to re...

  7. Observations of rotation in JET plasmas with electron heating by ion cyclotron resonance heating

    DEFF Research Database (Denmark)

    Hellsten, T.; Johnson, T. J.; Van Eester, D.

    2012-01-01

    is better than with coupled power, indicating that for these types of discharges the dominating mechanism for the rotation is related to indirect effects of electron heat transport, rather than to direct effects of ICRF heating. There is no conclusive evidence that mode conversion in itself affects rotation...

  8. Pitch angle scattering of relativistic electrons near electromagnetic ion cyclotron resonances in diverging magnetic fields

    Science.gov (United States)

    Eliasson, B.; Papadopoulos, K.

    2017-10-01

    A theoretical study of the propagation of left-hand polarized shear Alfvén waves in spatially decreasing magnetic field geometries near the EMIC resonance, including the spectrum and amplitude of the mode converted EMIC waves and the pitch angle scattering of relativistic electrons transiting the resonant region, is presented. The objective of the paper is to motivate an experimental study of the subject using the UCLA LAPD chamber. The results are relevant in exploring the possibility that shear Alfvén waves strategically injected into the radiation belts using either ionospheric heating from ground based RF transmitters or injected by transmitters based on space platforms can enhance the precipitation rate of trapped relativistic electrons. Effects of multi-ionic composition are also investigated.

  9. Experimental Demonstration of an Electromagnetically Pumped Free-Electron Laser with Cyclotron Harmonic Idlers

    Science.gov (United States)

    1990-02-01

    points, conclusions, and recommendations for future work. 10 Magnetic field coils Anular electron edump beam dump Waveguide cutoff region Figure 2...magnetic field comp~onenit of the pump wave in gauss (C). A simple estimate is madle ly noting that the 50-MWf, TM01 pumip wave must flow through at...of the current flowing down the cathode stalk. The probe is formed by breaking the continuitv of the loop. then connecting a piece of coaxial cable

  10. Effect of Oblique Electromagnetic Ion Cyclotron Waves on Relativistic Electron Scattering: CRRES Based Calculation

    Science.gov (United States)

    Gamayunov, K. V.; Khazanov, G. V.

    2007-01-01

    We consider the effect of oblique EMIC waves on relativistic electron scattering in the outer radiation belt using simultaneous observations of plasma and wave parameters from CRRES. The main findings can be s ummarized as follows: 1. In 1comparison with field-aligned waves, int ermediate and highly oblique distributions decrease the range of pitc h-angles subject to diffusion, and reduce the local scattering rate b y an order of magnitude at pitch-angles where the principle absolute value of n = 1 resonances operate. Oblique waves allow the absolute va lue of n > 1 resonances to operate, extending the range of local pitc h-angle diffusion down to the loss cone, and increasing the diffusion at lower pitch angles by orders of magnitude; 2. The local diffusion coefficients derived from CRRES data are qualitatively similar to the local results obtained for prescribed plasma/wave parameters. Conseq uently, it is likely that the bounce-averaged diffusion coefficients, if estimated from concurrent data, will exhibit the dependencies similar to those we found for model calculations; 3. In comparison with f ield-aligned waves, intermediate and highly oblique waves decrease th e bounce-averaged scattering rate near the edge of the equatorial lo ss cone by orders of magnitude if the electron energy does not excee d a threshold (approximately equal to 2 - 5 MeV) depending on specified plasma and/or wave parameters; 4. For greater electron energies_ ob lique waves operating the absolute value of n > 1 resonances are more effective and provide the same bounce_averaged diffusion rate near the loss cone as fiel_aligned waves do.

  11. A free-electron laser for cyclotron resonant heating in magnetic fusion reactors

    Science.gov (United States)

    Freund, H. P.; Read, M. E.; Jackson, R. H.; Pershing, D. E.; Taccetti, J. M.

    1995-05-01

    A G-band free-electron laser designed for plasma heating is described using a coaxial hybrid iron (CHI) wiggler formed by insertion into a solenoid of a central rod and an outer ring of alternating ferrite and nonferrite spacers positioned so that the central ferrite (nonferrite) spacers are opposite the outer nonferrite (ferrite) spacers. The CHI wiggler provides for enhanced beam focusing and the ability to handle intense beams and high-power continuous wave radiation. Simulations indicate that a power/efficiency of 3.5 MW/13% are possible using a 690 kV/40 A beam. No beam loss was found in simulation.

  12. Development of portable mass spectrometer with electron cyclotron resonance ion source for detection of chemical warfare agents in air.

    Science.gov (United States)

    Urabe, Tatsuya; Takahashi, Kazuya; Kitagawa, Michiko; Sato, Takafumi; Kondo, Tomohide; Enomoto, Shuichi; Kidera, Masanori; Seto, Yasuo

    2014-01-01

    A portable mass spectrometer with an electron cyclotron resonance ion source (miniECRIS-MS) was developed. It was used for in situ monitoring of trace amounts of chemical warfare agents (CWAs) in atmospheric air. Instrumental construction and parameters were optimized to realize a fast response, high sensitivity, and a small body size. Three types of CWAs, i.e., phosgene, mustard gas, and hydrogen cyanide were examined to check if the mass spectrometer was able to detect characteristic elements and atomic groups. From the results, it was found that CWAs were effectively ionized in the miniECRIS-MS, and their specific signals could be discerned over the background signals of air. In phosgene, the signals of the 35Cl+ and 37Cl+ ions were clearly observed with high dose-response relationships in the parts-per-billion level, which could lead to the quantitative on-site analysis of CWAs. A parts-per-million level of mustard gas, which was far lower than its lethal dosage (LCt50), was successfully detected with a high signal-stability of the plasma ion source. It was also found that the chemical forms of CWAs ionized in the plasma, i.e., monoatomic ions, fragment ions, and molecular ions, could be detected, thereby enabling the effective identification of the target CWAs. Despite the disadvantages associated with miniaturization, the overall performance (sensitivity and response time) of the miniECRIS-MS in detecting CWAs exceeded those of sector-type ECRIS-MS, showing its potential for on-site detection in the future. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. Effect of electron cyclotron beam width to neoclassical tearing mode stabilization by minimum seeking control in ITER

    Science.gov (United States)

    Park, Minho; Na, Yong-Su; Seo, Jaemin; Kim, M.; Kim, Kyungjin

    2018-01-01

    We report the effect of the electron cyclotron (EC) beam width on the full suppression time of neoclassical tearing mode (NTM) using the finite difference method (FDM) based minimum seeking controller in ITER. An integrated numerical system is setup for time-dependent simulations of the NTM evolution in ITER by solving the modified Rutherford equation together with the plasma equilibrium, transport, and EC heating and current drive. The calculated magnetic island width and growth rate is converted to the Mirnov diagnostic signal as an input to the controller to mimic the real experiment. In addition, 10% of the noise is enforced to this diagnostic signal to evaluate the robustness of the controller. To test the dependency of the NTM stabilization time on the EC beam width, the EC beam width scan is performed for a perfectly aligned case first, then for cases with the feedback control using the minimum seeking controller. When the EC beam is perfectly aligned, the narrower the EC beam width, the smaller the NTM stabilization time is observed. As the beam width increases, the required EC power increases exponentially. On the other hand, when the minimum seeking controller is applied, NTM stabilization sometimes fails as the EC beam width decreases. This is consistently observed in the simulation with various representations of the noise as well as without the noise in the Mirnov signal. The higher relative misalignment, misalignment divided by the beam width, is found to be the reason for the failure with the narrower beam widths. The EC stabilization effect can be lower for the narrower beam widths than the broader ones even at the same misalignment due to the smaller ECCD at the island O-point. On the other hand, if the EC beam is too wide, the NTM stabilization time takes too long. Accordingly, the optimal EC beam width range is revealed to exist in the feedback stabilization of NTM.

  14. Mechanical analyses of the waveguide flange coupling for the first confinement system of the ITER electron cyclotron upper launcher

    Energy Technology Data Exchange (ETDEWEB)

    Mas Sánchez, Avelino, E-mail: avelino.massanchez@epfl.ch [Ecole Polytechnique Fédérale de Lausanne (EPFL), Centre de Recherches en Physique des Plasmas (CRPP), CH-1015 Lausanne (Switzerland); Bertizzolo, Robert; Chavan, René [Ecole Polytechnique Fédérale de Lausanne (EPFL), Centre de Recherches en Physique des Plasmas (CRPP), CH-1015 Lausanne (Switzerland); Gagliardi, Mario [Fusion for Energy, Josep Pla 2, Barcelona 08019 (Spain); Goodman, Timothy; Landis, Jean-Daniel [Ecole Polytechnique Fédérale de Lausanne (EPFL), Centre de Recherches en Physique des Plasmas (CRPP), CH-1015 Lausanne (Switzerland); Saibene, Gabriella [Fusion for Energy, Josep Pla 2, Barcelona 08019 (Spain); Santos Silva, Phillip [Ecole Polytechnique Fédérale de Lausanne (EPFL), Centre de Recherches en Physique des Plasmas (CRPP), CH-1015 Lausanne (Switzerland); Vaccaro, Alessandro [Karlsruhe Institute of Technology, D-76021 Karlsruhe (Germany)

    2016-11-01

    Highlights: • A double-metallic-seal waveguide flange coupling, capable of withstanding the expected load specification, has been designed. • The numerical simulations have shown that bending is the dominant load configuration for the current coupling concept. • The numerical studies indicate that an excessive seal decompression will not occur due to the expected load configurations. • Experimental tests show a good agreement with the results obtained in the numerical analyses. - Abstract: The four electron cyclotron (EC) upper port antennas (or “upper launchers” —UL) will be used to drive current locally inside magnetic islands located at the q = 2 (or smaller) rational surfaces in order to stabilize neoclassical tearing modes (NTMs), as well as heat inside of ρ of about 0.4. Each antenna consists of eight beam lines that are designed for the transmission of 1.5 MW of mm-wave power at 170 GHz. The First Confinement System (FCS) is formed by the ex-vessel mm-wave waveguide components, for which SIC-1 classification requirements apply. The beam lines in the FCS comprise a Z shaped set of straight corrugated waveguides with a nominal diameter of 50 mm connected by miter bends. This system is subjected to imposed displacements coming mainly from the thermal expansion of the vacuum vessel, seismic events and/or plasma disruption events. In absence of suitable SIC-1 waveguide bellows, the FCS waveguides must provide the necessary mechanical functional compliance. This has required the development of a dedicated, flange type coupling system with double metallic seals, capable of resisting the generated external loads while maintaining vacuum tightness and alignment. This paper presents the results of the design, analysis and pre-qualification experimental work done on the waveguides and the integrated SIC-1 compliant coupling system.

  15. Intense beam production of highly charged heavy ions by the superconducting electron cyclotron resonance ion source SECRAL.

    Science.gov (United States)

    Zhao, H W; Sun, L T; Zhang, X Z; Guo, X H; Cao, Y; Lu, W; Zhang, Z M; Yuan, P; Song, M T; Zhao, H Y; Jin, T; Shang, Y; Zhan, W L; Wei, B W; Xie, D Z

    2008-02-01

    There has been increasing demand to provide higher beam intensity and high enough beam energy for heavy ion accelerator and some other applications, which has driven electron cyclotron resonance (ECR) ion source to produce higher charge state ions with higher beam intensity. One of development trends for highly charged ECR ion source is to build new generation ECR sources by utilization of superconducting magnet technology. SECRAL (superconducting ECR ion source with advanced design in Lanzhou) was successfully built to produce intense beams of highly charged ion for Heavy Ion Research Facility in Lanzhou (HIRFL). The ion source has been optimized to be operated at 28 GHz for its maximum performance. The superconducting magnet confinement configuration of the ion source consists of three axial solenoid coils and six sextupole coils with a cold iron structure as field booster and clamping. An innovative design of SECRAL is that the three axial solenoid coils are located inside of the sextupole bore in order to reduce the interaction forces between the sextupole coils and the solenoid coils. For 28 GHz operation, the magnet assembly can produce peak mirror fields on axis of 3.6 T at injection, 2.2 T at extraction, and a radial sextupole field of 2.0 T at plasma chamber wall. During the commissioning phase at 18 GHz with a stainless steel chamber, tests with various gases and some metals have been conducted with microwave power less than 3.5 kW by two 18 GHz rf generators. It demonstrates the performance is very promising. Some record ion beam intensities have been produced, for instance, 810 e microA of O(7+), 505 e microA of Xe(20+), 306 e microA of Xe(27+), and so on. The effect of the magnetic field configuration on the ion source performance has been studied experimentally. SECRAL has been put into operation to provide highly charged ion beams for HIRFL facility since May 2007.

  16. Progress of superconducting electron cyclotron resonance ion sources at Institute of Modern Physics (IMP).

    Science.gov (United States)

    Sun, L; Lu, W; Feng, Y C; Zhang, W H; Zhang, X Z; Cao, Y; Zhao, Y Y; Wu, W; Yang, T J; Zhao, B; Zhao, H W; Ma, L Z; Xia, J W; Xie, D

    2014-02-01

    Superconducting ECR ion sources can produce intense highly charged ion beams for the application in heavy ion accelerators. Superconducting Electron Resonance ion source with Advanced Design (SECRAL) is one of the few fully superconducting ECR ion sources that has been successfully built and put into routine operation for years. With enormous efforts and R&D work, promising results have been achieved with the ion source. Heated by the microwave power from a 7 kW/24 GHz gyrotron microwave generator, very intense highly charged gaseous ion beams have been produced, such as 455 eμA Xe(27+), 236 eμA Xe(30+), and 64 eμA Xe(35+). Since heavy metallic ion beams are being more and more attractive and important for many accelerator projects globally, intensive studies have been made to produce highly charged heavy metal ion beams, such as those from bismuth and uranium. Recently, 420 eμA Bi(30+) and 202 eμA U(33+) have been produced with SECRAL source. This paper will present the latest results with SECRAL, and the operation status will be discussed as well. An introduction of recently started SECRAL II project will also be given in the presentation.

  17. Development of a 2 MW CW Waterload for Electron Cyclotron Heating Systems

    Energy Technology Data Exchange (ETDEWEB)

    R. Lawrence,Ives; Maxwell Mizuhara; George Collins; Jeffrey Neilson; Philipp Borchard

    2012-11-09

    Calabazas Creek Research, Inc. developed a load capable of continuously dissipating 2 MW of RF power from gyrotrons. The input uses HE11 corrugated waveguide and a rotating launcher to uniformly disperse the power over the lossy surfaces in the load. This builds on experience with a previous load designed to dissipate 1 MW of continuous RF power. The 2 MW load uses more advanced RF dispersion to double the capability in the same size device as the 1 MW load. The new load reduces reflected power from the load to significantly less than 1 %. This eliminates requirements for a preload to capture reflected power. The program updated control electronics that provides all required interlocks for operation and measurement of peak and average power. The program developed two version of the load. The initial version used primarily anodized aluminum to reduce weight and cost. The second version used copper and stainless steel to meet specifications for the ITER reactor currently under construction in France. Tests of the new load at the Japanese Atomic Energy Agency confirmed operation of the load to a power level of 1 MW, which is the highest power currently available for testing the load. Additional tests will be performed at General Atomics in spring 2013. The U.S. ITER organization will test the copper/stainless steel version of the load in December 2012 or early in 2013. Both loads are currently being marketed worldwide.

  18. Studies of extraction and transport system for highly charged ion beam of 18 GHz superconducting electron cyclotron resonance ion source at Research Center for Nuclear Physics.

    Science.gov (United States)

    Yorita, T; Hatanaka, K; Fukuda, M; Ueda, H; Yasuda, Y; Morinobu, S; Tamii, A; Kamakura, K

    2014-02-01

    An 18 GHz superconducting electron cyclotron resonance ion source is installed to increase beam currents and to extend the variety of ions especially for highly charged heavy ions which can be accelerated by cyclotrons of Research Center for Nuclear Physics (RCNP), Osaka University. The beam production developments of several ions from B to Xe have been already done [T. Yorita, K. Hatanaka, M. Fukuda, M. Kibayashi, S. Morinobu, H.Okamura, and A. Tamii, Rev. Sci. Instrum. 79, 02A311 (2008) and T. Yorita, K. Hatanaka, M. Fukuda, M. Kibayashi, S. Morinobu, H.Okamura, and A. Tamii, Rev. Sci. Instrum. 81, 02A332 (2010)] and the further studies for those beam extraction and its transport have been done in order to increase the beam current more. The plasma electrode, extraction electrode, and einzel lens are modified. Especially extraction electrode can be applied minus voltage for the beam extraction and it works well to improve the extracted beam current. The extraction voltage dependences of transmission and emittance also have been studied for beam current improvement which is injected into azimuthally varying field cyclotron at RCNP.

  19. Forecasting electron cyclotron current drive stabilization of neoclassical tearing modes in ITER

    Science.gov (United States)

    La Haye, Robert J.

    2017-10-01

    The ITER baseline design relies on ECCD to stabilize confinementdegrading disruptive NTMs [1]. However, the EC power required will take a toll on the fusion gain Q. The MDC-8 group (in existence since 2005) has the goal to provide a range of data to benchmark the Rutherford tearing stability equation for NTM evolution, allowing predictions for ITER ECCD requirements to be validated. Experimental contributors have included ASDEX UPGRADE, DIII-D, EAST, FTU, HL-2A, JT-60U, KSTAR, TEXTOR and TCV. While any m/n tearing mode island can reduce confinement, the m=2, n=1 mode at q=2 is particularly damaging. This mode is at a relatively large minor radius in the low q95˜3 safety factor of ITER and thus close to the resistive wall; with the relatively low rotation in ITER (large inertia, small torque), an uncontrolled mode will rapidly lock at low tearing mode amplitude with subsequent disruption [2]. While progress is being made in modeling of the stability space and control [3] and experiments are promising, implementation still needs to be successfully demonstrated experimentally. The ITPA consensus is that ITER's 24 1-MW gyrotrons will provide more than sufficient EC power from the upper launch mirrors to drive narrow (but not too narrow) ECCD at q=2 for stabilization, with good alignment. Broadening of the ECCD, by edge turbulence for example, is a concern that would demand more EC power but also make alignment easier. Pre-emption at lower CW power or active stabilization by early mode onset detection and higher peak (possibly lower average) pulsed power are issues still under continuing investigation. Most EC-NTM experimental studies so far are at relatively high q95 with smaller radius at q=2 and thus higher Te for better current drive efficiency, higher rotation and weaker wall coupling. DIII-D, for example, is now well poised to pursue ECCD NTM stabilization at both low q95 and at low rotation in the 2017 campaign. The MDC-8 as a whole is proceeding to narrow the

  20. Electron-cyclotron maser utilizing free-electron two-quantum magnetic-wiggler radiation, and explanation of effective laser injection in an electron cyclotron maser as lift-up of saturated power level arisen from uncertainty in electron energy due to electron's transverse wiggling

    Science.gov (United States)

    Kim, S. H.

    2017-12-01

    We reason that in the free-electron radiation if the transition rate τ is less than the radiation frequency ν, the radiation is of broad-band spectrum whereas if τ ≫ ν, the radiation is of monochromatic. We find that when a weaker magnetic wiggler (MW) is superpositioned on a predominantly strong uniform magnetic field, free-electron two-quantum magnetic-wiggler (FETQMW) radiation takes place. In FETQMW radiation, the MW and the electron's intrinsic motivity to change its internal configuration through radiation play as two first-order perturbers while the uniform magnetic field acts as the sole zeroth-order perturber. When Δ E≪ hν, where Δ E is the uncertainty in the electron energy produced by transverse wiggling due to the MW in conjuction with a Heisenberg's uncertainty principle Δ EΔ x h and E = ( m 2 c 4 + c 2 p 2)1/2, the power of FETQMW radiation cannot exceed hν 2. However, we find that this power cap is lifted by the amount of νΔ E when Δ E ≫ hν holds [1,2]. This lift-up of the saturated radiation power is the responsible mechanism for the effective external injection of a 20 kW maser in an electron-cyclotron maser (ECM). We find that an MW-added ECM with radius 5 cm and length 1 m and operating parameters of the present beam technology can yield laser power of 50 MW at the radiation wavelength of 0.001 cm.

  1. Numerical study of the synergy effects of electron cyclotron wave and two lower-hybrid waves in the current drive process

    Science.gov (United States)

    Yang, Youlei; Xiang, Nong; Hu, Ye Min

    2017-08-01

    In recent experiments on the experimental advanced superconducting tokamak, the electron cyclotron wave and the two lower-hybrid waves at different frequencies, i.e., 4.6 GHz and 2.45 GHz, are applied simultaneously to sustain and control the plasma current. To investigate the synergy effects of the three waves, the Fokker-Planck equation with the quasi-linear diffusions induced by the three waves is solved numerically with the CQL3D code [R. W. Harvey and M. G. McCoy, in Proceedings of IAEA Technical Committee Meeting on Advances in Simulation and Modeling of Thermonuclear Plasmas, Montreal, Canada (1992)]. It is found that there might be strong synergy effects between the three waves. The electrons in the low velocity region in the velocity space can be accelerated perpendicularly by the electron cyclotron wave, and their parallel velocities can be increased due to scattering and fall into the resonance regions of the lower-hybrid waves. Therefore, such processes may bring more electrons to resonate with the lower-hybrid waves and enhance the current drive of the lower-hybrid waves. The synergy effects strongly depend on the distance between the resonance regions in the velocity space of the three waves.

  2. Heavy-ion injector based on an electron cyclotron ion source for the superconducting linear accelerator of the Rare Isotope Science Project.

    Science.gov (United States)

    Hong, In-Seok; Kim, Yong-Hwan; Choi, Bong-Hyuk; Choi, Suk-Jin; Park, Bum-Sik; Jin, Hyun-Chang; Kim, Hye-Jin; Heo, Jeong-Il; Kim, Deok-Min; Jang, Ji-Ho

    2016-02-01

    The injector for the main driver linear accelerator of the Rare Isotope Science Project in Korea, has been developed to allow heavy ions up to uranium to be delivered to the inflight fragmentation system. The critical components of the injector are the superconducting electron cyclotron resonance (ECR) ion sources, the radio frequency quadrupole (RFQ), and matching systems for low and medium energy beams. We have built superconducting magnets for the ECR ion source, and a prototype with one segment of the RFQ structure, with the aim of developing a design that can satisfy our specifications, demonstrate stable operation, and prove results to compare the design simulation.

  3. Two-slope soft X-ray spectra observed in experiments on electron cyclotron resonance plasma heating in the L-2M stellarator

    Science.gov (United States)

    Meshcheryakov, A. I.; Vafin, I. Yu.; Grishina, I. A.; Letunov, A. A.; Tereshchenko, M. A.

    2017-06-01

    In experiments on the generation and electron cyclotron resonance heating (ECRH) of plasma in the L-2M stellarator, non-Maxwellian two-slope soft X-ray (SXR) spectra were observed. The temperatures of the thermal and epithermal components of the spectra were measured as functions of the heating power and plasma density. A hypothesis based on the experimental results is suggested to explain the formation mechanism of two-slope SXR spectra in the ECRH experiments at the L-2M stellarator. The measured SXR spectra are compared with the results of numerical simulations.

  4. A fresh look at electron cyclotron current drive power requirements for stabilization of tearing modes in ITER

    Energy Technology Data Exchange (ETDEWEB)

    La Haye, R. J., E-mail: lahaye@fusion.gat.com [General Atomics, P.O. Box 85608, San Diego, California 92186-5608 (United States)

    2015-12-10

    ITER is an international project to design and build an experimental fusion reactor based on the “tokamak” concept. ITER relies upon localized electron cyclotron current drive (ECCD) at the rational safety factor q=2 to suppress or stabilize the expected poloidal mode m=2, toroidal mode n=1 neoclassical tearing mode (NTM) islands. Such islands if unmitigated degrade energy confinement, lock to the resistive wall (stop rotating), cause loss of “H-mode” and induce disruption. The International Tokamak Physics Activity (ITPA) on MHD, Disruptions and Magnetic Control joint experiment group MDC-8 on Current Drive Prevention/Stabilization of Neoclassical Tearing Modes started in 2005, after which assessments were made for the requirements for ECCD needed in ITER, particularly that of rf power and alignment on q=2 [1]. Narrow well-aligned rf current parallel to and of order of one percent of the total plasma current is needed to replace the “missing” current in the island O-points and heal or preempt (avoid destabilization by applying ECCD on q=2 in absence of the mode) the island [2-4]. This paper updates the advances in ECCD stabilization on NTMs learned in DIII-D experiments and modeling during the last 5 to 10 years as applies to stabilization by localized ECCD of tearing modes in ITER. This includes the ECCD (inside the q=1 radius) stabilization of the NTM “seeding” instability known as sawteeth (m/n=1/1) [5]. Recent measurements in DIII-D show that the ITER-similar current profile is classically unstable, curvature stabilization must not be neglected, and the small island width stabilization effect from helical ion polarization currents is stronger than was previously thought [6]. The consequences of updated assumptions in ITER modeling of the minimum well-aligned ECCD power needed are all-in-all favorable (and well-within the ITER 24 gyrotron capability) when all effects are included. However, a “wild card” may be broadening of the localized

  5. Efficiency of the generation of impulsion by cyclotron waves currents of the electrons in an Axisymmetric Tokamak; Eficiencia de la generacion de corrientes de impulsion por ondas ciclotronicas de los electrones en un Tokamak axisimetrico

    Energy Technology Data Exchange (ETDEWEB)

    Gutierrez T, C.; Beltran P, M. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    2004-07-01

    The neoclassical theory of transport is used to calculate the current efficiency of electronic cyclotron impulsion (ECCD) in an axisymmetric tokamak in the few collisions regime. The standard parameter of the tokamak is used to obtain a system of equations that describe the hydrodynamic of the plasma, where the ponderomotive force (PM) due to high power radio frequency waves is taken in account. The PM force is produced in the proximity of electron cyclotron resonance surface in a specific poloidal localization. The efficiency ECCD is analyzed in the cases of first and second harmonic (for different angles of injection of radio frequency waves) and it is validated using the experimental values of the TCV and T-10 tokamaks. The results are according to those obtained by means of the techniques of the Green functions. (Author)

  6. Study of electronic heat transport in plasma through diagnosis based on modulated electron cyclotron heating; Etudes de transport de la chaleur electronique par injection modulee d'ondes a la frequence cyclotronique electronique

    Energy Technology Data Exchange (ETDEWEB)

    Clemencon, A.; Guivarch, C

    2003-07-01

    In order to make nuclear fusion energetically profitable, it is crucial to heat and confine the plasma efficiently. Studying the behavior of the heat diffusion coefficient is a key issue in this matter. The use of modulated electron cyclotron heating as a diagnostic has suggested the existence of a transport barrier under certain plasma conditions. We have determined the solution to the heat transport equation, for several heat diffusion coefficient profiles. By comparing the analytical solutions with experimental data; we are able to study the heat diffusion coefficient profile. Thus, in certain experiments, we can confirm that the heat diffusion coefficient switches from low to high values at the radius where the electron cyclotron heat deposition is made. (authors)

  7. CLOVERLEAF CYCLOTRON

    Science.gov (United States)

    McMillan, E.M.; Judd, D.L.

    1959-02-01

    A cyclotron is presented embodying a unique magnetic field configuration, which configuration increases in intensity with radius and therefore compensates for the reltivistic mass effect, the field having further convolutions productive of axial stability in the particle beam. By reconciling the seemingly opposed requirements of mass increase compensation on one hand and anial stability on the other, the production of extremely high current particle beams in the relativistie energy range is made feasible. Certain further advantages inhere in the invention, notably an increase in the usable magnet gap, simplified and more efficient extraction of the beam from the accelerator, and ready adaptation to the use of multiply phased excitation as contrasted with the single phased systems herstofore utilized. General

  8. A gas-jet transport and catcher technique for on-line production of radioactive ion beams using an electron cyclotron resonance ion-source

    Energy Technology Data Exchange (ETDEWEB)

    Naik, V.; Chakrabarti, A.; Bhattacharjee, M.; Karmakar, P.; Bandyopadhyay, A.; Dechoudhury, S.; Mondal, M.; Pandey, H. K.; Lavanyakumar, D.; Mandi, T. K.; Dutta, D. P.; Kundu Roy, T.; Bhowmick, D.; Sanyal, D.; Srivastava, S. C. L.; Ray, A.; Ali, Md. S. [Variable Energy Cyclotron Centre (VECC), Sector-1, Block-AF, Bidhan Nagar, Kolkata 700064 (India); Bhattacharjee, S. [UGC-DAE CSR, Kolkata Centre, III/LB-8, Bidhan Nagar, Kolkata 700098 (India)

    2013-03-15

    Radioactive ion beams (RIB) have been produced on-line, using a gas-jet recoil transport coupled Electron Cyclotron Resonance (ECR) ion-source at the VECC-RIB facility. Radioactive atoms/molecules carried through the gas-jet were stopped in a catcher placed inside the ECR plasma chamber. A skimmer has been used to remove bulk of the carrier gas at the ECR entrance. The diffusion of atoms/molecules through the catcher has been verified off-line using stable isotopes and on-line through transmission of radioactive reaction products. Beams of {sup 14}O (71 s), {sup 42}K (12.4 h), {sup 43}K (22.2 h), and {sup 41}Ar (1.8 h) have been produced by bombarding nitrogen and argon gas targets with proton and alpha particle beams from the K130 cyclotron at VECC. Typical measured intensity of RIB at the separator focal plane is found to be a few times 10{sup 3} particles per second (pps). About 3.2 Multiplication-Sign 10{sup 3} pps of 1.4 MeV {sup 14}O RIB has been measured after acceleration through a radiofrequency quadrupole linac. The details of the gas-jet coupled ECR ion-source and RIB production experiments are presented along with the plans for the future.

  9. Proposal and verification numerical simulation for a microwave forward scattering technique at upper hybrid resonance for the measurement of electron gyroscale density fluctuations in the electron cyclotron frequency range in magnetized plasmas

    Science.gov (United States)

    Kawamori, E.; Igami, H.

    2017-11-01

    A diagnostic technique for detecting the wave numbers of electron density fluctuations at electron gyro-scales in an electron cyclotron frequency range is proposed, and the validity of the idea is checked by means of a particle-in-cell (PIC) numerical simulation. The technique is a modified version of the scattering technique invented by Novik et al. [Plasma Phys. Controlled Fusion 36, 357-381 (1994)] and Gusakov et al., [Plasma Phys. Controlled Fusion 41, 899-912 (1999)]. The novel method adopts forward scattering of injected extraordinary probe waves at the upper hybrid resonance layer instead of the backward-scattering adopted by the original method, enabling the measurement of the wave-numbers of the fine scale density fluctuations in the electron-cyclotron frequency band by means of phase measurement of the scattered waves. The verification numerical simulation with the PIC method shows that the technique has a potential to be applicable to the detection of electron gyro-scale fluctuations in laboratory plasmas if the upper-hybrid resonance layer is accessible to the probe wave. The technique is a suitable means to detect electron Bernstein waves excited via linear mode conversion from electromagnetic waves in torus plasma experiments. Through the numerical simulations, some problems that remain to be resolved are revealed, which include the influence of nonlinear processes such as the parametric decay instability of the probe wave in the scattering process, and so on.

  10. Rapid Profiling of Bovine and Human Milk Gangliosides by Matrix-Assisted Laser Desorption/Ionization Fourier Transform Ion Cyclotron Resonance Mass Spectrometry.

    Science.gov (United States)

    Lee, Hyeyoung; An, Hyun Joo; Lerno, Larry A; German, J Bruce; Lebrilla, Carlito B

    2011-08-15

    Gangliosides are anionic glycosphingolipids widely distributed in vertebrate tissues and fluids. Their structural and quantitative expression patterns depend on phylogeny and are distinct down to the species level. In milk, gangliosides are exclusively associated with the milk fat globule membrane. They may participate in diverse biological processes but more specifically to host-pathogen interactions. However, due to the molecular complexities, the analysis needs extensive sample preparation, chromatographic separation, and even chemical reaction, which makes the process very complex and time-consuming. Here, we describe a rapid profiling method for bovine and human milk gangliosides employing matrix-assisted desorption/ionization (MALDI) Fourier transform ion cyclotron resonance (FTICR) mass spectrometry (MS). Prior to the analyses of biological samples, milk ganglioside standards GM3 and GD3 fractions were first analyzed in order to validate this method. High mass accuracy and high resolution obtained from MALDI FTICR MS allow for the confident assignment of chain length and degree of unsaturation of the ceramide. For the structural elucidation, tandem mass spectrometry (MS/MS), specifically as collision-induced dissociation (CID) and infrared multiphoton dissociation (IRMPD) were employed. Complex ganglioside mixtures from bovine and human milk were further analyzed with this method. The samples were prepared by two consecutive chloroform/methanol extraction and solid phase extraction. We observed a number of differences between bovine milk and human milk. The common gangliosides in bovine and human milk are NeuAc-NeuAc-Hex-Hex-Cer (GD3) and NeuAc-Hex-Hex-Cer (GM3); whereas, the ion intensities of ganglioside species are different between two milk samples. Kendrick mass defect plot yields grouping of ganglioside peaks according to their structural similarities. Gangliosides were further probed by tandem MS to confirm the compositional and structural assignments

  11. Rapid method to estimate temperature changes in electronics elements

    Directory of Open Access Journals (Sweden)

    Oborskii G. A., Savel’eva O. S., Shikhireva Yu. V.

    2014-06-01

    Full Text Available Thermal behavior of electronic equipment is the determining factor for performing rapid assessment of the effectiveness of design and operation of the equipment. The assessment method proposed in this article consists in fixation of an infrared video stream from the surface of the device and converting it into a visible flow by means of a thermal imager, splitting it into component colors and their further processing using parabolic transformation. The result of the transformation is the number used as a rapid criterion for estimation of distribution stability of heat in the equipment.

  12. A liquid-helium-free superconducting coil system forming a flat minimum-magnetic-field distribution of an electron cyclotron resonance ion source.

    Science.gov (United States)

    Yoshida, Ken-ichi; Nara, Takayuki; Saitoh, Yuichi; Yokota, Watalu

    2014-02-01

    A flat distribution of the minimum magnetic field (flat-Bmin) of an electron cyclotron resonance ion source (ECRIS) is expected to perform better in highly charged ion production than classical Bmin. To form a flat-Bmin structure with a liquid helium-free superconducting device, a coil system of seven coils with four current leads has been designed. The lead number was reduced by connecting the plural coils in series to maintain the flat-Bmin structure even when the coil currents are changed for adjustment. This coil system can be operated with a helium-free cryostat, since the estimation of heat from the leads to the coils is nearly equivalent to the existing superconducting ECRIS of a similar type.

  13. A liquid-helium-free superconducting coil system forming a flat minimum-magnetic-field distribution of an electron cyclotron resonance ion source

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Ken-ichi, E-mail: yoshida.kennichi71@jaea.go.jp; Nara, Takayuki; Saitoh, Yuichi; Yokota, Watalu [Takasaki Advanced Radiation Research Institute, Japan Atomic Energy Agency, 1233 Watanuki, Takasaki, Gunma 370-1292 (Japan)

    2014-02-15

    A flat distribution of the minimum magnetic field (flat-B{sub min}) of an electron cyclotron resonance ion source (ECRIS) is expected to perform better in highly charged ion production than classical B{sub min}. To form a flat-B{sub min} structure with a liquid helium-free superconducting device, a coil system of seven coils with four current leads has been designed. The lead number was reduced by connecting the plural coils in series to maintain the flat-B{sub min} structure even when the coil currents are changed for adjustment. This coil system can be operated with a helium-free cryostat, since the estimation of heat from the leads to the coils is nearly equivalent to the existing superconducting ECRIS of a similar type.

  14. A liquid-helium-free superconducting coil system forming a flat minimum-magnetic-field distribution of an electron cyclotron resonance ion source

    Science.gov (United States)

    Yoshida, Ken-ichi; Nara, Takayuki; Saitoh, Yuichi; Yokota, Watalu

    2014-02-01

    A flat distribution of the minimum magnetic field (flat-Bmin) of an electron cyclotron resonance ion source (ECRIS) is expected to perform better in highly charged ion production than classical Bmin. To form a flat-Bmin structure with a liquid helium-free superconducting device, a coil system of seven coils with four current leads has been designed. The lead number was reduced by connecting the plural coils in series to maintain the flat-Bmin structure even when the coil currents are changed for adjustment. This coil system can be operated with a helium-free cryostat, since the estimation of heat from the leads to the coils is nearly equivalent to the existing superconducting ECRIS of a similar type.

  15. Observation of an edge coherent mode and poloidal flow in the electron cyclotron wave induced high β{sub p} plasma in QUEST

    Energy Technology Data Exchange (ETDEWEB)

    Banerjee, Santanu, E-mail: sbanerje@ipr.res.in; Mishra, K. [Institute for Plasma Research, Bhat, Gandhinagar 382428, Gujarat (India); Zushi, H.; Mahira, Y.; Tashima, S.; Onchi, T.; Nagashima, Y.; Hanada, K.; Nakamura, K.; Idei, H.; Hasegawa, M.; Fujisawa, A.; Kuzmin, A.; Matsuoka, K. [RIAM, Kyushu University, 6-1 Kasuga Koen, Kasuga-shi, Fukuoka 816-8580 (Japan); Nishino, N. [Mechanical System Engineering, Hiroshima University, Hiroshima 739-8527 (Japan); Ejiri, A.; Yamaguchi, T. [Graduate School of Frontier Sciences, Tokyo University, Kashiwa 277-8561 (Japan)

    2016-08-15

    Fluctuations are measured in the edge and scrape-off layer (SOL) of QUEST using fast visible imaging diagnostic. Electron cyclotron wave injection in the Ohmic plasma features excitation of low frequency coherent fluctuations near the separatrix and enhanced cross-field transport. Plasma shifts from initial high field side limiter bound (inboard limited, IL) towards inboard poloidal null (IPN) configuration with steepening of the density profile at the edge. This may have facilitated the increased edge and SOL fluctuation activities. Observation of the coherent mode, associated plasma flow, and particle out-flux, for the first time in the IPN plasma configuration in a spherical tokamak may provide further impetus to the edge and SOL turbulence studies in tokamaks.

  16. Zn-vapor diffused Er:Yb:LiNbO 3 channel waveguides fabricated by means of SiO 2 electron cyclotron resonance plasma deposition

    Science.gov (United States)

    Pernas, P. L.; Hernández, M. J.; Ruíz, E.; Cantelar, E.; Nevado, R.; Morant, C.; Lifante, G.; Cussó, F.

    2000-07-01

    We report here the fabrication method and operation of Zinc-vapor diffused channel waveguides on Erbium/Ytterbium (Er/Yb)-doped Lithium Niobate (LiNbO 3). electron cyclotron resonance (ECR) plasma deposition technique, UV photolithography and Reactive Ion Etching (RIE) are used to define an SiO 2 mask for pattern transfer. The whole process is performed at low temperatures eliminating typical LiO 2 out-diffusion problems and achieving low surface damage. The flexibility of the fabrication technology has been shown to be potentially applicable to integrated optics. EDAX measurements reveal good confinement and homogeneity of the diffused regions. Atomic Force Microscopy (AFM) surface characterization shows the swelling of the diffused areas, consistent with the topoepitaxial growth of a Zn xLi yNb zO w layer.

  17. Effects of Electron-Cyclotron-Resonance Oxygen Plasma Irradiation on Properties of Insulator/Ge-Semiconductor Interfaces Prior to Germanium Nitride Formation

    Science.gov (United States)

    Otani, Yohei; Fukuda, Yukio; Sato, Tetsuya; Nakagawa, Kiyokazu; Toyota, Hiroshi; Ono, Toshiro

    2008-09-01

    Electron-cyclotron-resonance (ECR) oxygen (O2) plasma was irradiated onto the surface of germanium (Ge) substrates prior to germanium nitride (GeNx) formation. Germanium metal-insulator-semiconductor (Ge-MIS) structures with a 5-nm-thick silicon nitride/2-nm-thick GeNx gate insulator stack fabricated by ECR plasma nitridation and sputtering deposition without substrate heating were electrically and physically characterized. Although ECR O2 plasma irradiation onto the surface of Ge substrates caused no significant difference in the chemical state of GeNx/Ge interfaces in X-ray photoemission spectroscopic measurement, irradiation for an appropriate period improved the state of GeNx/Ge interfaces and the electrical properties of Ge-MIS.

  18. Surface passivation of p-type Ge substrate with high-quality GeNx layer formed by electron-cyclotron-resonance plasma nitridation at low temperature

    Science.gov (United States)

    Fukuda, Yukio; Okamoto, Hiroshi; Iwasaki, Takuro; Otani, Yohei; Ono, Toshiro

    2011-09-01

    We have investigated the effects of the formation temperature and postmetallization annealing (PMA) on the interface properties of GeNx/p-Ge fabricated by the plasma nitridation of Ge substrates using an electron-cyclotron-resonance-generated nitrogen plasma. The nitridation temperature is found to be a critical parameter in improving the finally obtained GeNx/Ge interface properties. The GeNx/Ge formed at room temperature and treated by PMA at 400 °C exhibits the best interface properties with an interface trap density of 1 × 1011 cm-2 eV-1. The GeNx/Ge interface is unpinned and the Fermi level at the Ge surface can move from the valence band edge to the conduction band edge.

  19. Effects of initial layers on surface roughness and crystallinity of microcrystalline silicon thin films formed by remote electron cyclotron resonance silane plasma

    CERN Document Server

    Murata, K; Hori, Masaki; Goto, T; Ito, M

    2002-01-01

    We have observed mu c-Si:H films grown in the glass substrate in electron cyclotron resonance plasma-enhanced chemical vapor deposition employing two-step growth (TSG) method, where the seed layer was formed without charged species firstly, and subsequently, the film with charged species. The mu c-Si:H films with smooth surface and high crystallinity were synthesized with a relatively high deposition rate at a low substrate temperature by TSG. By Fourier transform infrared attenuated-total reflection, it was found that the surface roughness and crystallinity of seed layer were related to the ratio of SiH bonds over SiH sub 2 ones in the film. Consequently, the control of chemical bonds at the initial layer is of importance and TSG method is effective for the formation of mu c-Si:H film with high quality.

  20. First commissioning results with the Grenoble test electron cyclotron resonance ion source at iThemba LABS

    Energy Technology Data Exchange (ETDEWEB)

    Thomae, R.; Conradie, J.; Delsink, H.; Du Plessis, H.; Fourie, D.; Klopp, M.; Kohler, I.; Lussi, C.; McAlister, R.; Ntshangase, S.; Sakildien, M. [iThemba LABS, P.O Box 722, Somerset West 7130 (South Africa); Hitz, D. [CEA/DRFMC, 17 Av. Des Martyrs, 38054, Grenoble Cedex 9 (France); Kuechler, D. [CERN, BE/ABP/HSL, 1211 Geneva 23 (Switzerland)

    2012-02-15

    iThemba Laboratory for Accelerator Based Science (iThemba LABS) is a multi-disciplinary accelerator facility. One of its main activities is the operation of a separated-sector cyclotron with a K-value of 200, which provides beams of various ion species. These beams are used for fundamental nuclear physics research in the intermediate energy region, radioisotope production, and medical physics applications. Due to the requirements of nuclear physics for new ion species and higher energies, the decision was made to install a copy of the so-called Grenoble test source (GTS) at iThemba LABS. In this paper, we will report on the experimental setup and the first results obtained with the GTS2 at iThemba LABS.

  1. Monte Carlo simulation of cyclotron resonant scattering features

    Science.gov (United States)

    Schwarm, Fritz-Walter; Schönherr, Gabriele; Wilms, Joern

    In the regime of very high magnetic fields on the order of 10(12} mathrm{G) the electron momenta perpendicular to the field are quantized due to the discrete Landau levels populated by the electrons. Parallel to the magnetic field the electrons form a continuous momentum distribution. The seed photon continuum is generated for example by bremsstrahlung or blackbody radiation. Resonant scattering of a seed photon by an electron may excite the electron to a higher Landau level. The subsequent de-excitation of the excited electron produces additional photons close to the resonance energy. This way complex cyclotron resonant scattering features (CRSFs) are imprinted on the continuum radiation. Due to the continuous electron momentum distribution parallel to the magnetic field the scattering photon's energy and angle are mixed by Lorentz transformation to the electron rest frame in which the resonant scattering process is being carried out. Therefore synthetic spectra of cyclotron lines can not be accurately calculated analytically. CRSFs have been observed in more than a dozen accreting X-ray binaries. They provide much information about the accretion structure in the observed systems since the exact line shape is sensitive to many parameters in the column. Typical parameters are for example the geometry and the spectral properties of seed photon sources, the geometry of the column, or the magnetic field and temperature within the column. We present an overview over the Monte-Carlo approach to cyclotron line simulation and show results from our texttt{cyclosim} code. Furthermore we investigate the influence of the accretion geometry on the cyclotron line shape. Our code enables us to perform fully relativistic simulations including the correct cyclotron scattering cross sections and the possibility to cope with parameter gradients such as magnetic field, temperature, or velocity gradients within the accretion column. Using a Green's function approach these simulations

  2. Surface treatment of a-axis EuBa2Cu3O7 - y thin films by an electron cyclotron resonance ion beam

    Science.gov (United States)

    Asano, H.; Asahi, M.; Kimachi, Y.

    1993-07-01

    An electron cyclotron resonance (ECR) ion beam has been utilized for a developing surface cleaning process of high-Tc superconducting thin films. By means of silver-contact resistivity measurements, and ex situ surface analysis using x-ray photoelectron spectroscopy (XPS) and reflection high-energy electron diffraction (RHEED), the effects of ECR treatment on an air-exposed surface of a-axis EuBa2Cu3O7-y (EBCO) films are examined. Ag/EBCO contacts are made with exposure of the EBCO surface to an ECR oxygen ion beam with ion current densities of 100 μA/cm2 at room temperature for about 30 min and the in situ deposition of silver. The contacts, which are not annealed in oxygen, exhibit low contact resistivity in the 10-8-10-7 Ω cm2 range. These values are about five orders of magnitude lower than those of samples fabricated without ECR treatment. Based on XPS and RHEED data, change in the EBCO surface caused by ECR treatment is surmised.

  3. Cyclotrons: From Science to Human Health

    Science.gov (United States)

    Craddock, Michael

    2011-04-01

    Lawrence's invention of the cyclotron, whose 80th anniversary we have just celebrated, not only revolutionized nuclear physics, but proved the starting point for a whole variety of recirculating accelerators, from the smallest microtron to the largest synchrotron, that have had an enormous impact in almost every branch of science and in several areas of medicine and industry. Cyclotrons themselves have proved remarkably adaptable, incorporating a variety of new ideas and technologies over the years: frequency modulation, edge focusing, AG focusing, separate magnet sectors, axial and azimuthal injection, ring geometries, stripping extraction, superconducting magnets and rf...... Even FFAGs, those most complex members of the cyclotron (fixed-magnetic-field) family, are making a comeback. Currently there are more than 50 medium or large cyclotrons around the world devoted to research. These provide intense primary beams of protons or stable ions, and correspondingly intense secondary beams of neutrons, pions, muons and radioactive ions, for experiments in nuclear, particle and condensed-matter physics, and in the materials and life sciences. Far outnumbering these, however, are the 800 or so small and medium cyclotrons used to produce radioisotopes for medical and other purposes. In addition, a rapidly growing number of 230-MeV proton cyclotrons are being built for cancer therapy -12 brought into operation since 1998 and as many more in the works. Altogether, cyclotrons are flourishing!

  4. Rapid detection of intracellular nanoparticles by electron microscopy

    Directory of Open Access Journals (Sweden)

    Kyoung Hwan Lee

    2010-03-01

    Full Text Available Recently, a number of nanoparticle carriers have provided new platforms for research in biotechnology and biomedicine. A particularly interest in these fields is the monitoring of nanoparticle delivery to target cells. Since the structures involved are on a nanometer scale, high resolution imaging, such as electron microscopy, is required. Aside from assessing the structural characteristics of the target sites localized with the nanoparticles, an electron microscope can also be used to observe the biological effects of the nanoparticles on the cells. It can also be used to test and detect a wide range of fluorescent nanoparticles and nanoassemblies. Although this approach has many advantages, most researchers are unwilling to try electron microscopy due to the complicated specimen preparation procedures and time-consuming process. Here, we developed a method to simplify the sample preparation and shorten the total processing time. In particular, double staining was removed, and cryo-preparation was included. Using this simple and rapid sample preparation, we were able to observe nanoparticles with high-contrast images of the cellular organelles. This efficient detection method can be applied to studies on nanoparticle drug delivery systems and nanoparticle-cell interactions.

  5. Reflection and backscattering of microwaves under doubling of the plasma density and displacement of the gyroresonance region during electron cyclotron resonance heating of plasma in the l-2M stellarator

    Energy Technology Data Exchange (ETDEWEB)

    Batanov, G. M.; Borzosekov, V. D.; Vasilkov, D. G.; Kolik, L. V.; Konchekov, E. M., E-mail: konchekov@fpl.gpi.ru; Malakhov, D. V.; Vafin, I. Yu.; Petrov, A. E.; Sarksyan, K. A.; Sakharov, A. S.; Stepakhin, V. D.; Kharchev, N. K. [Russian Academy of Sciences, Prokhorov General Physics Institute (Russian Federation)

    2016-08-15

    Reflection and backscattering of high-power (400 kW) gyrotron radiation creating and heating plasma at the second harmonic of the electronic cyclotron frequency in the L-2M stellarator have been investigated experimentally. The effect of the displacement of the gyroresonance region from the axis of the plasma column under doubling of the plasma density on the processes of reflection and backscattering of microwave radiation has been examined. A near doubling of short-wavelength (k{sub ⊥} ≈ 30 cm{sup –1}) turbulent density fluctuations squared is observed. The change in the energy confinement time under variations of plasma parameters and characteristics of short-wavelength turbulence is discussed. A discrepancy between the measured values of the reflection coefficient from the electron cyclotron resonance heating region and predictions of the one-dimensional model is revealed.

  6. Photoelectron Spectroscopy of EuBa2Cu3O7-y Thin Film Surfaces Treated by an Electron Cyclotron Resonance Oxygen Ion Beam

    Science.gov (United States)

    Asano, Hidefumi; Suzuki, Minoru; Kiyokura, Takanori; Maeda, Fumihiko; Menz, Andreas; Watanabe, Yoshio; Oshima, Masaharu

    1995-04-01

    Surface modification of EuBa2Cu3O7- y (EBCO) thin films induced by an electron cyclotron resonance (ECR) oxygen ion beam treatment has been studied using X-ray and synchrotron-radiation photoelectron spectroscopy (XPS and SRPES). The in situ characterization has been performed during the course of 50 eV ECR oxygen treatment for 30 min. Time-dependent analysis shows that the contaminant carbon layer on the surface region can be removed at the initial stage of the treatment (<2 min), and that the copper valence of the surfaces can be recovered to Cu2+ after 30 min treatment. It is found that room-temperature treatment using ECR oxygen can alter the contaminated, oxygen-depleted surface to a clean, well-oxygenated surface. The present results suggest that ECR treatment which can modify the surfaces in a well-defined manner would be a feasible technique for surface cleaning of high-temperature superconductors.

  7. Operation of Lanzhou all permanent electron cyclotron resonance ion source No. 2 on 320 kV platform with highly charged ions.

    Science.gov (United States)

    Lu, W; Li, J Y; Kang, L; Liu, H P; Li, H; Li, J D; Sun, L T; Ma, X W

    2014-02-01

    The 320 kV platform for multi-discipline research with highly charged ions is a heavy ion beam acceleration instrument developed by Institute of Modern Physics, which is dedicated to basic scientific researches such as plasma, atom, material physics, and astrophysics, etc. The platform has delivered ion beams of 400 species for 36,000 h. The average operation time is around 5000 h/year. With the beams provided by the platform, lots of outstanding progresses were made in various research fields. The ion source of the platform is an all-permanent magnet electron cyclotron resonance ion source, LAPECR2 (Lanzhou All Permanent ECR ion source No. 2). The maximum axial magnetic fields are 1.28 T at injection and 1.07 T at extraction, and the radial magnetic field is up to 1.21 T at the inner wall of the plasma chamber. The ion source is capable to produce low, medium, and high charge state gaseous and metallic ion beams, such as H(+), (40)Ar(8+), (129)Xe(30+), (209)Bi(33+), etc. This paper will present the latest result of LAPECR2 and the routine operation status for the high voltage platform.

  8. A near infra-red video system as a protective diagnostic for electron cyclotron resonance heating operation in the Wendelstein 7-X stellarator.

    Science.gov (United States)

    Preynas, M; Laqua, H P; Marsen, S; Reintrog, A; Corre, Y; Moncada, V; Travere, J-M

    2015-11-01

    The Wendelstein 7-X stellarator is a large nuclear fusion device based at Max-Planck-Institut für Plasmaphysik in Greifswald in Germany. The main plasma heating system for steady state operation in W7-X is electron cyclotron resonance heating (ECRH). During operation, part of plama facing components will be directly heated by the non-absorbed power of 1 MW rf beams of ECRH. In order to avoid damages of such components made of graphite tiles during the first operational phase, a near infra-red video system has been developed as a protective diagnostic for safe and secure ECRH operation. Both the mechanical design housing the camera and the optical system are very flexible and respect the requirements of steady state operation. The full system including data acquisition and control system has been successfully tested in the vacuum vessel, including on-line visualization and data storage of the four cameras equipping the ECRH equatorial launchers of W7-X.

  9. A near infra-red video system as a protective diagnostic for electron cyclotron resonance heating operation in the Wendelstein 7-X stellarator

    Energy Technology Data Exchange (ETDEWEB)

    Preynas, M.; Laqua, H. P.; Marsen, S.; Reintrog, A. [Max-Planck-Institut für Plasmaphysik (IPP), D-17491 Greifswald (Germany); Corre, Y.; Moncada, V.; Travere, J.-M. [IRFM, CEA-Cadarache, 13108 Saint Paul lez Durance Cedex (France)

    2015-11-15

    The Wendelstein 7-X stellarator is a large nuclear fusion device based at Max-Planck-Institut für Plasmaphysik in Greifswald in Germany. The main plasma heating system for steady state operation in W7-X is electron cyclotron resonance heating (ECRH). During operation, part of plama facing components will be directly heated by the non-absorbed power of 1 MW rf beams of ECRH. In order to avoid damages of such components made of graphite tiles during the first operational phase, a near infra-red video system has been developed as a protective diagnostic for safe and secure ECRH operation. Both the mechanical design housing the camera and the optical system are very flexible and respect the requirements of steady state operation. The full system including data acquisition and control system has been successfully tested in the vacuum vessel, including on-line visualization and data storage of the four cameras equipping the ECRH equatorial launchers of W7-X.

  10. Ion Behavior and Gas Mixing in electron cyclotron resonance plasmas as sources of highly charged ions (concept

    NARCIS (Netherlands)

    Melin, G.; Drentje, A. G.; Girard, A.; Hitz, D.

    1999-01-01

    Abstract: An ECR ion source is basically an ECR heated plasma confinement machine, with hot electrons and cold ions. The main parameters of the ion population have been analyzed, including temperature, losses, and confinement time. The "gas mixing" effect has been studied in this context. An

  11. Correlation of III/V semiconductor etch results with physical parameters of high-density reactive plasmas excited by electron cyclotron resonance

    Science.gov (United States)

    Gerhard, FRANZ; Ralf, MEYER; Markus-Christian, AMANN

    2017-12-01

    Reactive ion etching is the interaction of reactive plasmas with surfaces. To obtain a detailed understanding of this process, significant properties of reactive composite low-pressure plasmas driven by electron cyclotron resonance (ECR) were investigated and compared with the radial uniformity of the etch rate. The determination of the electronic properties of chlorine- and hydrogen-containing plasmas enabled the understanding of the pressure-dependent behavior of the plasma density and provided better insights into the electronic parameters of reactive etch gases. From the electrical evaluation of I(V) characteristics obtained using a Langmuir probe, plasmas of different compositions were investigated. The standard method of Druyvesteyn to derive the electron energy distribution functions by the second derivative of the I(V) characteristics was replaced by a mathematical model which has been evolved to be more robust against noise, mainly, because the first derivative of the I(V) characteristics is used. Special attention was given to the power of the energy dependence in the exponent. In particular, for plasmas that are generated by ECR with EM modes, the existence of Maxwellian distribution functions is not to be taken as a self-evident fact, but the bi-Maxwellian distribution was proven for Ar- and Kr-stabilized plasmas. In addition to the electron temperature, the global uniform discharge model has been shown to be useful for calculating the neutral gas temperature. To what extent the invasive method of using a Langmuir probe could be replaced with the non-invasive optical method of emission spectroscopy, particularly actinometry, was investigated, and the resulting data exhibited the same relative behavior as the Langmuir data. The correlation with etchrate data reveals the large chemical part of the removal process—most striking when the data is compared with etching in pure argon. Although the relative amount of the radial variation of plasma density and

  12. An electronic application for rapidly calculating Charlson comorbidity score

    Directory of Open Access Journals (Sweden)

    Jani Ashesh B

    2004-12-01

    Full Text Available Abstract Background Uncertainty regarding comorbid illness, and ability to tolerate aggressive therapy has led to minimal enrollment of elderly cancer patients into clinical trials and often substandard treatment. Increasingly, comorbid illness scales have proven useful in identifying subgroups of elderly patients who are more likely to tolerate and benefit from aggressive therapy. Unfortunately, the use of such scales has yet to be widely integrated into either clinical practice or clinical trials research. Methods This article reviews evidence for the validity of the Charlson Comorbidity Index (CCI in oncology and provides a Microsoft Excel (MS Excel Macro for the rapid and accurate calculation of CCI score. The interaction of comorbidity and malignant disease and the validation of the Charlson Index in oncology are discussed. Results The CCI score is based on one year mortality data from internal medicine patients admitted to an inpatient setting and is the most widely used comorbidity index in oncology. An MS Excel Macro file was constructed for calculating the CCI score using Microsoft Visual Basic. The Macro is provided for download and dissemination. The CCI has been widely used and validated throughout the oncology literature and has demonstrated utility for most major cancers. The MS Excel CCI Macro provides a rapid method for calculating CCI score with or without age adjustments. The calculator removes difficulty in score calculation as a limitation for integration of the CCI into clinical research. The simple nature of the MS Excel CCI Macro and the CCI itself makes it ideal for integration into emerging electronic medical records systems. Conclusions The increasing elderly population and concurrent increase in oncologic disease has made understanding the interaction between age and comorbid illness on life expectancy increasingly important. The MS Excel CCI Macro provides a means of increasing the use of the CCI scale in clinical

  13. A hybrid electron cyclotron resonance metal ion source with integrated sputter magnetron for the production of an intense Al{sup +} ion beam

    Energy Technology Data Exchange (ETDEWEB)

    Weichsel, T., E-mail: tim.weichsel@fep.fraunhofer.de; Hartung, U.; Kopte, T. [Fraunhofer Institute for Organic Electronics, Electron Beam and Plasma Technology FEP, 01277 Dresden (Germany); Zschornack, G. [Institute of Solid State Physics, Dresden University of Technology, 01062 Dresden, Germany and Helmholtz-Zentrum Dresden-Rossendorf e.V., Institute of Ion Beam Physics and Materials Research, Dresden (Germany); Kreller, M.; Philipp, A. [DREEBIT GmbH, 01900 Grossroehrsdorf (Germany)

    2015-09-15

    A metal ion source prototype has been developed: a combination of magnetron sputter technology with 2.45 GHz electron cyclotron resonance (ECR) ion source technology—a so called magnetron ECR ion source (MECRIS). An integrated ring-shaped sputter magnetron with an Al target is acting as a powerful metal atom supply in order to produce an intense current of singly charged metal ions. Preliminary experiments show that an Al{sup +} ion current with a density of 167 μA/cm{sup 2} is extracted from the source at an acceleration voltage of 27 kV. Spatially resolved double Langmuir probe measurements and optical emission spectroscopy were used to study the plasma states of the ion source: sputter magnetron, ECR, and MECRIS plasma. Electron density and temperature as well as Al atom density were determined as a function of microwave and sputter magnetron power. The effect of ECR heating is strongly pronounced in the center of the source. There the electron density is increased by one order of magnitude from 6 × 10{sup 9} cm{sup −3} to 6 × 10{sup 10} cm{sup −3} and the electron temperature is enhanced from about 5 eV to 12 eV, when the ECR plasma is ignited to the magnetron plasma. Operating the magnetron at constant power, it was observed that its discharge current is raised from 1.8 A to 4.8 A, when the ECR discharge was superimposed with a microwave power of 2 kW. At the same time, the discharge voltage decreased from about 560 V to 210 V, clearly indicating a higher plasma density of the MECRIS mode. The optical emission spectrum of the MECRIS plasma is dominated by lines of excited Al atoms and shows a significant contribution of lines arising from singly ionized Al. Plasma emission photography with a CCD camera was used to prove probe measurements and to identify separated plasma emission zones originating from the ECR and magnetron discharge.

  14. The Effect of Electron Cyclotron Heating on Multi-Scale Fluctuations in ITER Baseline Scenario Discharges on DIII-D

    Science.gov (United States)

    Maronini, A.; Rost, J. C.; Porkolab, M.; Davis, E. M.; Pinsker, R. I.; Burrell, K. H.; Staebler, G. M.; Grierson, B. A.

    2016-10-01

    Experiments on DIII-D simulating the ITER Baseline Scenario show that torque-free pure electron heating (ECH) modifies profiles and affects density fluctuations at electron and at ion scales in different ways. The Phase Contrast Imaging diagnostic is used to measure the time evolution of density fluctuations going from mixed beam/ECH to pure beam heating at fixed βN. The intensity of fluctuations at scales between 2 and 5 cm-1 increases promptly after turning off ECH; at larger scales, in contrast, it decreases only after other equilibrium quantities have evolved to a new stationary state. Non-linear gyro-kinetic simulations suggest that the former response is due to ETG modes that also generate a prompt inward particle pinch; the latter is consistent with the dominant ITG modes being weakened by the increased flow shear in the new state. Such fluctuations in ITER might affect fusion performance via modifications to steady-state profiles. Work supported by the US Department of Energy under DE-FG02-94ER54235 and DE-FC02-04ER54698.

  15. Metamaterial Lens of Specifiable Frequency-Dependent Focus and Adjustable Aperture for Electron Cyclotron Emission in the DIII-D Tokamak

    Science.gov (United States)

    Hammond, K. C.; Massidda, S. D.; Capecchi, W. J.; Volpe, F. A.

    2013-08-01

    Electron Cyclotron Emission (ECE) of different frequencies originates at different locations in non-uniformly magnetized plasmas. For simultaneous observation of multiple ECE frequencies from the outside edge of a toroidal plasma confinement device (e.g. a tokamak), the focal length of the collecting optics should increase with the frequency to maximize the resolution on a line of sight along the magnetic field gradient. Here we present the design and numerical study of a zoned metamaterial lens with such characteristics, for possible deployment with the 83-130 GHz ECE radiometer in the DIII-D tokamak. The lens consists of a concentric array of miniaturized element phase-shifters. These were reverse-engineered starting from the desired Gaussian beam waist locations and further optimized to account for diffraction and finite-aperture effects that tend to displace the waist. At the same time we imposed high and uniform transmittance, averaged over all phase-shifters. The focal length is shown to increase from 1.32 m to 2.08 m over the frequency range of interest, as desired for low-field DIII-D discharges (B = -1.57 T). Retracting the lens to receded positions rigidly moves the waists accordingly, resulting in a good match—within a fraction of the Rayleigh length—of the EC-emitting layer positions at higher fields (up to B= -2.00 T). Further, it is shown how varying the lens aperture might move the waists "non-rigidly" to better match the non-rigid movement of the EC-emitting layers with the magnetic field. The numerical method presented is very general and can be used to engineer any dependence of the focal length on the frequency, including zero or minimal chromatic aberration.

  16. The effect of cavity tuning on oxygen beam currents of an A-ECR type 14 GHz electron cyclotron resonance ion source

    Energy Technology Data Exchange (ETDEWEB)

    Tarvainen, O., E-mail: olli.tarvainen@jyu.fi; Orpana, J.; Kronholm, R.; Kalvas, T.; Laulainen, J.; Koivisto, H. [Department of Physics (JYFL), University of Jyväskylä, 40500 Jyväskylä (Finland); Izotov, I.; Skalyga, V. [Institute of Applied Physics, RAS, 46 Ul’yanova St., 603950 Nizhny Novgorod (Russian Federation); Lobachevsky State University of Nizhny Novgorod (UNN), 23 Gagarina St., 603950 Nizhny Novgorod (Russian Federation); Toivanen, V. [European Organization for Nuclear Research (CERN), 1211 Geneva 23 (Switzerland)

    2016-09-15

    The efficiency of the microwave-plasma coupling plays a significant role in the production of highly charged ion beams with electron cyclotron resonance ion sources (ECRISs). The coupling properties are affected by the mechanical design of the ion source plasma chamber and microwave launching system, as well as damping of the microwave electric field by the plasma. Several experiments attempting to optimize the microwave-plasma coupling characteristics by fine-tuning the frequency of the injected microwaves have been conducted with varying degrees of success. The inherent difficulty in interpretation of the frequency tuning results is that the effects of microwave coupling system and the cavity behavior of the plasma chamber cannot be separated. A preferable approach to study the effect of the cavity properties of the plasma chamber on extracted beam currents is to adjust the cavity dimensions. The results of such cavity tuning experiments conducted with the JYFL 14 GHz ECRIS are reported here. The cavity properties were adjusted by inserting a conducting tuner rod axially into the plasma chamber. The extracted beam currents of oxygen charge states O{sup 3+}–O{sup 7+} were recorded at various tuner positions and frequencies in the range of 14.00–14.15 GHz. It was observed that the tuner position affects the beam currents of high charge state ions up to several tens of percent. In particular, it was found that at some tuner position / frequency combinations the plasma exhibited “mode-hopping” between two operating regimes. The results improve the understanding of the role of plasma chamber cavity properties on ECRIS performances.

  17. Ion Behavior and Gas Mixing in electron cyclotron resonance plasmas as sources of highly charged ions (concept)

    CERN Document Server

    Melin, G; Girard, A; Hitz, D

    1999-01-01

    An ECR ion source is basically an ECR heated plasma confinement machine, with hot electrons and cold ions. The main parameters of the ion population have been analyzed, including temperature, losses, and confinement time. The "gas mixing" effect has been studied in this context. An expression is derived for determining the ion temperature from the values of all extracted ion currents. One aim is to study the ion temperature behavior in argon plasmas without and with mixing different gases into the plasma. For that purpose a series of experiments has been performed where systematically one or a few parameters where changed. One conclusion is that the ion temperature indeed is decreasing due to gas mixing. A second conclusion is that the decreasing ion temperature is not a sufficient requirement for the beneficial effect of gas mixing to the production of highest charge states of argon.

  18. Synchro-cyclotron

    CERN Multimedia

    CERN PhotoLab

    1972-01-01

    The electromagnetic coil which forms the first section of the proton extraction channel in the improved synchro-cyclotron. The photograph shows the positioning gear and the current septum. An extraction efficiency above 50% is expected.

  19. Dynamics of the storm time ring current and relativistic electrons : particle scattering by ion cyclotron waves inside the anisotropic proton zone

    Energy Technology Data Exchange (ETDEWEB)

    Sandanger, Marit Irene J.

    2009-07-01

    processes with no new injections of ring current particles and the Dst recovers fast to quiet day values. Paper II investigated the precipitation of relativistic electrons throughout a geomagnetic storm, and how their loss relates to the precipitating ring current protons. The precipitation of relativistic electrons takes place within the anisotropic proton zone. Inside this region, proton spikes will be found in association with increased loss of relativistic electrons. The proton population of the anisotropic proton zone and in the proton spikes are unstable and can cause growth of Electromagnetic Ion Cyclotron (EMIC) wave, which can in turn scatter relativistic electrons into the atmospheric loss cone. The precipitation of relativistic electrons are found at all Magnetic Local Time (MLT) considered in the study.

  20. Ion cyclotron resonance heating system on Aditya

    Indian Academy of Sciences (India)

    R. Narasimhan (Krishtel eMaging) 1461 1996 Oct 15 13:05:22

    1Institute for Plasma Research, Bhat, Gandhinagar 382 428, India. 2Variable Electron Cyclotron .... Requirements for RF generators for fusion research include high power, long pulse duration and reliability. ... Output of pre-driver (triode 3CX5000A7) grounded grid amplifier is made tunable within. 20 to 47 MHz by using a ...

  1. Measurements of the Suprathermal Electron Density Profile by Electron Cyclotron Emission at the Upper Cut-Off Layer in Tore Supra

    NARCIS (Netherlands)

    Schokker, B. C.; Talvard, M.; Cardozo, N. J. L.; Giruzzi, G.

    1995-01-01

    The possibility of measuring the radial profile of fast-electron distributions from ECE spectra is discussed. The most usual ECE diagnostic set-up, i.e. the second-harmonic X-mode, observed by low-held side antennae in the equatorial plane, can be used by exploiting the reflection of spontaneously

  2. Relativistic Cyclotron Resonance Shape in Magnetic Bottle Geonium

    National Research Council Canada - National Science Library

    Hans Dehmelt; Richard Mittleman; Yuan Liu

    1988-01-01

    The thermally excited axial oscillation of the electron through the weak magnetic bottle needed for the continuous Stern-Gerlach effect modulates the cyclotron frequency and produces a characteristic...

  3. Rapid Pitch Angle Evolution of Suprathermal Electrons Behind Dipolarization Fronts

    Science.gov (United States)

    Liu, C. M.; Fu, H. S.; Cao, J. B.; Xu, Y.; Yu, Y. Q.; Kronberg, E. A.; Daly, P. W.

    2017-10-01

    The pitch angle distribution (PAD) of suprathermal electrons can have both spatial and temporal evolution in the magnetotail and theoretically can be an indication of electron energization/cooling processes there. So far, the spatial evolution of PAD has been well studied, leaving the temporal evolution as an open question. To reveal the temporal evolution of electron PAD, spacecraft should monitor the same flux tube for a relatively long period, which is not easy in the dynamic magnetotail. In this study, we present such an observation by Cluster spacecraft in the magnetotail behind a dipolarization front (DF). We find that the PAD of suprathermal electrons can evolve from pancake type to butterfly type during effect, which possibly exists behind the DF as well.

  4. Rapid energization of radiation belt electrons by nonlinear wave trapping

    Directory of Open Access Journals (Sweden)

    Y. Katoh

    2008-11-01

    Full Text Available We show that nonlinear wave trapping plays a significant role in both the generation of whistler-mode chorus emissions and the acceleration of radiation belt electrons to relativistic energies. We have performed particle simulations that successfully reproduce the generation of chorus emissions with rising tones. During this generation process we find that a fraction of resonant electrons are energized very efficiently by special forms of nonlinear wave trapping called relativistic turning acceleration (RTA and ultra-relativistic acceleration (URA. Particle energization by nonlinear wave trapping is a universal acceleration mechanism that can be effective in space and cosmic plasmas that contain a magnetic mirror geometry.

  5. Cyclotron Line Measurements with INTEGRAL

    Science.gov (United States)

    Pottschmidt, K.; Kreykenbohm, I.; Caballero, I.; Fritz, S.; Schoenherr, G.; Kretschmar, P.; Wilms, J.; McBride, V. A.; Suchy, S.; Rothschild, R. E.

    2008-01-01

    Due to its broadband energy coverage, INTEGRAL has made important contributions to observing and interpreting cyclotron lines, which are present in the 10-100 keV range of a sample of accreting pulsars. In these systems photons with energies fulfilling the resonance condition inelastically Compton scatter off electrons quantized in the accretion column above the neutron star's magnetic pole(s). This process gives rise to the broad, absorption-like lines or 'cyclotron resonant scattering features' (CRSF). The observed lines allow to directly measure the B-fields of these sources, resulting in values of a few times 1E12G. In this overview I will present recent highlights regarding CRSF observations as well as discuss current ideas and models for the physical conditions in the accretion column. Among the former are the stability of the spectrum of Vela X-1 during giant flares in 2003, the observation of three cyclotron lines during the 2004 outburst of V0332+53, the confirmation of the fundamental line at approximately 45 keV during a 2005 normal outburst of A0535-26, and the simultaneous detection of the two lines in the dipping source 4U 1907+09 (for which also a torque reversal was detected for the first time). Through these and other observations it has become increasingly apparent that two types of observations can potentially be used to constrain the accretion column geometry: the determination of energy ratios for multiple harmonic lines (only two sources with greater than 2 lines are known), was well as the evolution of the fundamental line centroid, which, for different sources, may or may not be correlated with flux. Furthermore, first steps have been taken away from the usual phenomenological description of the lines, towards a physical approach based on self-consistent CRSF modeling. Initial applications are presented.

  6. Thermal Improvement and Stability of Si3N4/GeNx/p- and n-Ge Structures Prepared by Electron-Cyclotron-Resonance Plasma Nitridation and Sputtering at Room Temperature

    Science.gov (United States)

    Fukuda, Yukio; Okamoto, Hiroshi; Iwasaki, Takuro; Izumi, Kohei; Otani, Yohei; Ishizaki, Hiroki; Ono, Toshiro

    2012-09-01

    This paper reports on the thermal improvement of Si3N4/GeNx/Ge structures. After the Si3N4 (5 nm)/GeNx (2 nm) stacks were prepared on Ge substrates by electron-cyclotron-resonance plasma nitridation and sputtering at room temperature, they were thermally annealed in atmospheric N2 + 10% H2 ambient at temperatures from 400 to 600 °C. It was demonstrated that the electronic properties of the GeNx/Ge interfaces were thermally improved at temperatures of up to 500 °C with a minimum interface trap density (Dit) of ˜1×1011 cm-2 eV-1 near the Ge midgap, whereas the interface properties were slightly degraded after annealing at 600 °C with a minimum Dit value of ˜4×1011 cm-2 eV-1.

  7. Interaction between fast ions and ion cyclotron heating in a tokamak plasma; Interaction des ions rapides avec les ondes a la frequence cyclotronique ionique dans un plasma de tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Bergeaud, V

    2001-11-01

    In an ignited fusion reactor, the plasma temperature is sustained by the fusion reactions. However, before this regime is reached, it is necessary to bring an additional power to the plasma. One of the methods that enables the coupling of power is the use of an electromagnetic wave in the ion cyclotron range of frequencies (ICRF). This thesis deals with the interaction between ICRF heating and the fast ions. The thesis contains a theoretical study of the influence of ICRF heating on the ion distribution function. A particular emphasis is put on the importance of the toroidal spectrum of the modes of propagation of the wave in the tokamak. It is necessary to take into account all these modes in order to correctly assess the strength of the wave particle interaction, especially for high energy particles (of the order of hundreds of keV). The classical treatment of the wave particle interaction is based on the hypothesis that the cyclotron phase of the particle and the wave phase are de-correlated between successive resonant interactions. One is therefore led to consider ICRF heating as a diffusive process. This hypothesis is reconsidered in this thesis and it is shown that strong correlations exist in a large part of the velocity space. For this study, a numerical code that computes the full trajectory of particles interacting with a complete electromagnetic field has been developed. The thesis also deals with the problem of fast ion losses due to the breaking of the toroidal symmetry of the confinement magnetic field (called the ripple modulation). Between two toroidal coils, local magnetic wells exist, and particles can be trapped there. When trapped they undergo a vertical drift that makes them quit the plasma rapidly. The ripple modulation also causes an enhancement of the radial diffusion, thereby increasing the losses. A Monte Carlo model describing these mechanisms is presented. This model is validated thanks to a comparison with an experimental database from

  8. Interaction of fast ions with ion cyclotron electromagnetic waves in tokamak plasma; Interaction des ions rapides avec les ondes a la frequence cyclotronique ionique dans un plasma de tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Bergeaud, V

    2000-12-01

    In an ignited fusion reactor, the plasma temperature is sustained by the fusion reactions. However, before this regime is reached, it is necessary to bring an additional power to the plasma. One of the methods that enables the coupling of power is the use of an electromagnetic wave in the ion cyclotron range of frequencies (ICRF). This thesis deals with the interaction between ICRF heating and the fast ions. The thesis contains a theoretical study of the influence of ICRF heating on the ion distribution function. A particular emphasis is put on the importance of the toroidal spectrum of the modes of propagation of the wave in the tokamak. It is necessary to take into account all these modes in order to correctly assess the strength of the wave particle interaction, especially for high energy particles (of the order of hundreds of keV). The classical treatment of the wave particle interaction is based on the hypothesis that the cyclotron phase of the particle and the wave phase are de-correlated between successive resonant interactions. One is therefore led to consider ICRF heating as a diffusive process. This hypothesis is reconsidered in this thesis and it is shown that strong correlations exist in a large part of the velocity space. For this study, a numerical code that computes the full trajectory of particles interacting with a complete electromagnetic field has been developed. The thesis also deals with the problem of fast ion losses due to the breaking of the toroidal symmetry of the confinement magnetic field (called the ripple modulation). Between two toroidal coils, local magnetic wells exist, and particles can be trapped there. When trapped they undergo a vertical drift that makes them quit the plasma rapidly. The ripple modulation also causes an enhancement of the radial diffusion, thereby increasing the losses. A Monte Carlo model describing these mechanisms is presented. This model is validated thanks to a comparison with an experimental database from

  9. Quantifying the Precipitation Loss of Radiation Belt Electrons During a Rapid Dropout Event

    Science.gov (United States)

    Pham, K. H.; Tu, W.; Xiang, Z.

    2017-10-01

    Relativistic electron flux in the radiation belt can drop by orders of magnitude within the timespan of hours. In this study, we used the drift-diffusion model that includes azimuthal drift and pitch angle diffusion of electrons to simulate low-altitude electron distribution observed by POES/MetOp satellites for rapid radiation belt electron dropout event occurring on 1 May 2013. The event shows fast dropout of MeV energy electrons at L > 4 over a few hours, observed by the Van Allen Probes mission. By simulating the electron distributions observed by multiple POES satellites, we resolve the precipitation loss with both high spatial and temporal resolutions and a range of energies. We estimate the pitch angle diffusion coefficients as a function of energy, pitch angle, and L-shell and calculate corresponding electron lifetimes during the event. The simulation results show fast electron precipitation loss at L > 4 during the electron dropout, with estimated electron lifetimes on the order of half an hour for MeV energies. The electron loss rate shows strong energy dependence with faster loss at higher energies, which suggest that this dropout event is dominated by quick and localized scattering process that prefers higher energy electrons. The improved temporal and spatial resolutions of electron precipitation rates provided by multiple low-altitude observations can resolve fast-varying electron loss during rapid electron dropouts (over a few hours), which occur too fast for a single low-altitude satellite. The capability of estimating the fast-varying electron lifetimes during rapid dropout events is an important step in improving radiation belt model accuracy.

  10. Fabrication of Ta2O5/GeNx gate insulator stack for Ge metal-insulator-semiconductor structures by electron-cyclotron-resonance plasma nitridation and sputtering deposition techniques

    Science.gov (United States)

    Otani, Yohei; Itayama, Yasuhiro; Tanaka, Takuo; Fukuda, Yukio; Toyota, Hiroshi; Ono, Toshiro; Mitsui, Minoru; Nakagawa, Kiyokazu

    2007-04-01

    The authors have fabricated germanium (Ge) metal-insulator-semiconductor (MIS) structures with a 7-nm-thick tantalum pentaoxide (Ta2O5)/2-nm-thick germanium nitride (GeNx) gate insulator stack by electron-cyclotron-resonance plasma nitridation and sputtering deposition. They found that pure GeNx ultrathin layers can be formed by the direct plasma nitridation of the Ge surface without substrate heating. X-ray photoelectron spectroscopy revealed no oxidation of the GeNx layer after the Ta2O5 sputtering deposition. The fabricated MIS capacitor with a capacitance equivalent thickness of 4.3nm showed excellent leakage current characteristics. The interface trap density obtained by the modified conductance method was 4×1011cm-2eV-1 at the midgap.

  11. Ion cyclotron resonance heating system in the RT-1 magnetospheric plasma

    Science.gov (United States)

    Nishiura, M.; Kawazura, Y.; Yoshida, Z.; Kenmochi, N.; Yano, Y.; Saitoh, H.; Yamasaki, M.; Mushiake, T.; Kashyap, A.; Takahashi, N.; Nakatsuka, M.; Fukuyama, A.

    2017-08-01

    We have developed an ion cyclotron resonance frequency (ICRF) heating system for the Ring Trap 1 (RT-1) magnetospheric device. We excite slow waves from the polar region of the dipole magnetic field. The target helium plasma is produced by electron cyclotron heating. The electrons comprise high-temperature (>10 keV) and low-temperature (wave electric field in the plasma.

  12. Production of cyclotron radionuclides

    Energy Technology Data Exchange (ETDEWEB)

    Suh, Yong Sup; Lim, Sang Moo; Yang, Seung Dae; Chun, Kwon Soo; Ahn, Soon Hyuk; Yun, Yong Kee; Park, Hyun; Lee, Ji Sup; Lee, Jong Doo; Chai, Jong Seo; Kim, Yoo Seok; Hong, Sung Suk; Lee, Min Yong; Beak, Seung Ki [Korea Cancer Center Hospital, Seoul (Korea)

    1999-12-01

    In the project, 11,492mCi of {sup 201}Tl, 4,384mCi of {sup 67}Ga, 1,245mCi of {sup 123}l, 523mCi of [{sup 123}I]mlBG and 1,283mCi of {sup 18}FDG were supplied, and the revenue were 304,723,000won. In the production of RI, 13 deg for {sup 201}Tl and {sup 67}Ga, 45 deg for {sup 123}l angle solid target have been used, and liquid target system has been used for {sup 18}F production. For the efficient use of the cyclotron, the MC-50 cyclotron was opened to outside user and basic research project was carried out. The technical supports and radionuclides analysis were done during the execution of the research. Then the facilities of safety supervision and handling techniques of radioisotope production were improved. 7 refs., 9 figs., 8 tabs. (Author)

  13. Production of cyclotron radionuclides

    Energy Technology Data Exchange (ETDEWEB)

    Chun, Kwon Soo; Lim, Sang Moo; Yang, Seung Dae; Suh, Yong Sup; Ahn, Soon Hyuk; Yun, Yong Kee; Park, Hyun; Lee, Ji Sup; Chai, Jong Seo; Kim, Yoo Seok; Hong, Sung Suk; Lee, Min Yong; Beak, Seung Ki; Kim, Jang Hye; Kim, Gi Sup [Korea Cancer Center Hospital, Seoul (Korea)

    2000-12-01

    In the project, 12,077mCi of {sup 201}Tl, 5,717mCi of {sup 67}Ga, 2,096mCi of {sup 123}l, 482mCi of [{sup 123}I]mlBG and 2,738mCi of {sup 18}FDG were supplied, and the revenue were 387,253,000won. In the production of RI, 13 deg for {sup 201}Tl and {sup 67}Ga, 45 deg for {sup 123}l angle solid target have been used, and liquid target system has been used for {sup 18}F production. For the efficient use of the cyclotron, the MC-50 cyclotron was opened to outside user and basic research project was carried out. The technical supports and radionuclides analysis were done during the execution of the research. Then the facilities of safety supervision and handling techniques of radioisotope production were improved. 7 refs., 8 figs., 9 tabs. (Author)

  14. Cyclotrons and positron emitting radiopharmaceuticals

    Energy Technology Data Exchange (ETDEWEB)

    Wolf, A.P.; Fowler, J.S.

    1984-01-01

    The state of the art of Positron Emission Tomography (PET) technology as related to cyclotron use and radiopharmaceutical production is reviewed. The paper discusses available small cyclotrons, the positron emitters which can be produced and the yields possible, target design, and radiopharmaceutical development and application. 97 refs., 12 tabs. (ACR)

  15. Ion-Beam-Excited, Electrostatic, Ion Cyclotron Instability

    DEFF Research Database (Denmark)

    Michelsen, Poul; Pécseli, Hans; Juul Rasmussen, Jens

    1977-01-01

    The stability limits of the ion‐beam‐excited, electrostatic, ion cyclotron instability were investigated in a Q‐machine plasma where the electrons could be heated by microwaves. In agreement with theory, the beam energy necessary for excitation decreased with increasing electron temperature....

  16. Ion-Beam-Excited Electrostatic Ion Cyclotron Instability

    DEFF Research Database (Denmark)

    Michelsen, Poul; Pécseli, Hans; Juul Rasmussen, Jens

    1977-01-01

    The stability limits of the ion‐beam‐excited, electrostatic, ion cyclotron instability were investigated in a Q‐machine plasma where the electrons could be heated by microwaves. In agreement with theory, the beam energy necessary for excitation decreased with increasing electron temperature....

  17. Ammonia-treated N-(1-naphthyl) ethylenediamine dihydrochloride as a novel matrix for rapid quantitative and qualitative determination of serum free fatty acids by matrix-assisted laser desorption/ionization-Fourier transform ion cyclotron resonance mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Yaping [Department of Biophysics and Structural Biology, Institute of Basic Medical Sciences, Chinese Academy of Medical Sciences and School of Basic Medicine, Peking Union Medical College, 5 Dongdan San Tiao, Beijing 100005 (China); Wang, Yanmin [Department of Clinical Laboratory, Heze Municipal Hospital, Shandong (China); Guo, Shuai; Guo, Yumei; Liu, Hui [Department of Biophysics and Structural Biology, Institute of Basic Medical Sciences, Chinese Academy of Medical Sciences and School of Basic Medicine, Peking Union Medical College, 5 Dongdan San Tiao, Beijing 100005 (China); Li, Zhili, E-mail: lizhili@ibms.pumc.edu.cn [Department of Biophysics and Structural Biology, Institute of Basic Medical Sciences, Chinese Academy of Medical Sciences and School of Basic Medicine, Peking Union Medical College, 5 Dongdan San Tiao, Beijing 100005 (China)

    2013-09-10

    Graphical abstract: -- Highlights: •A novel MALDI matrix for the detection of serum free fatty acids is ammonia-treated N-(1-naphthyl) ethylenediamine dihydrochloride. •Multiple point internal standard calibration curves were constructed for nine FFAs, respectively, with excellent correlation coefficients between 0.991 and 0.999. •The MALDI-MS approach was used to rapidly differentiate the patients with and without hyperglycemia and healthy controls. -- Abstract: The blood free fatty acids (FFAs), which provide energy to the cell and act as substrates in the synthesis of fats, lipoproteins, liposaccharides, and eicosanoids, involve in a number of important physiological processes. In the present study, matrix-assisted laser desorption/ionization-Fourier transform ion cyclotron resonance mass spectrometry (MALDI-FTICR MS) with ammonia-treated N-(1-naphthyl) ethylenediamine dihydrochloride (ATNEDC) as a novel MALDI matrix in a negative ion mode was employed to directly quantify serum FFAs. Multiple point internal standard calibration curves between the concentration ratios of individual fatty acids to internal standard (IS, C{sub 17:0}) versus their corresponding intensity ratios were constructed for C{sub 14:0}, C{sub 16:1}, C{sub 16:0}, C{sub 18:0}, C{sub 18:1}, C{sub 18:2}, C{sub 18:3}, C{sub 20:4}, and C{sub 22:6}, respectively, in their mixture, with correlation coefficients between 0.991 and 0.999 and limits of detection (LODs) between 0.2 and 5.4 μM, along with the linear dynamic range of more than two orders of magnitude. The results indicate that the multiple point internal standard calibration could reduce the impact of ion suppression and improve quantification accuracy in the MALDI mode. The quantitative results of nine FFAs from 339 serum samples, including 161 healthy controls, 118 patients with hyperglycemia and 60 patients without hyperglycemia show that FFAs levels in hyperglycemic patient sera are significantly higher than those in healthy

  18. V.U.V. plasma spectroscopy diagnostic of electron cyclotron resonance multicharged ion sources; Diagnostic de plasmas crees dans des sources d'ions multicharges a resonance cyclotronique electronique par spectroscopie V.U.V

    Energy Technology Data Exchange (ETDEWEB)

    Berreby, R

    1997-12-15

    To characterize the multicharged ions within the plasma of an E.C.R. ion source, the V.U.V. spectroscopy is used as a non invasive diagnostic of excited matter. In E.C.R.I. S. (electron cyclotron resonance ion source) electrons are heated and magnetically confined within the mirror machine to overcome the successive ionization potentials of the desired elements. As the electrons bounce inside the magnetic configuration in their gyration movement, they interact with the microwaves injected into the source at the resonance frequency. To enhance the performances in high charge states and extracted currents delivered by E.C.R.I.S., the fundamental parameters of the plasma created in these machines must be known. The goal of spectroscopic diagnostics in the V.U.V. range installed on the sources is to determine electron density and temperature on one hand, and the ionic densities and confinement time on the other hand. We used microchannel plates as detector on a 3 meter grazing incidence spectrometer equipped with a 600 lines/mm holographic grating. The calibration of the whole grating with detector was performed by two different methods. These are the branching ratio and charge exchange methods. Identification of lines emitted by a plasma, which gather the whole charge states of ions is necessary to make an exhaustive study of the plasma state. And finally, the determination of plasma parameters like electron density and temperature and ion densities and confinement times that uses theoretical models were the aim of this work. (author)

  19. Ion cyclotron resonance cell

    Science.gov (United States)

    Weller, R.R.

    1995-02-14

    An ion cyclotron resonance cell is disclosed having two adjacent sections separated by a center trapping plate. The first section is defined by the center trapping plate, a first end trapping plate, and excitation and detector electrodes. The second section includes a second end trapping plate spaced apart from the center plate, a mirror, and an analyzer. The analyzer includes a wavelength-selective light detector, such as a detector incorporating an acousto-optical device (AOD) and a photodetector. One or more ion guides, grounded plates with holes for the ion beam, are positioned within the vacuum chamber of the mass spectrometer between the ion source and the cell. After ions are trapped and analyzed by ion cyclotron resonance techniques in the first section, the ions of interest are selected according to their mass and passed into the second section for optical spectroscopic studies. The trapped ions are excited by light from a laser and caused thereby to fluoresce. The fluorescent light emitted by the excited ions is reflected by the mirror and directed onto the detector. The AOD is scanned, and the photodetector output is recorded and analyzed. The ions remain in the second section for an extended period, enabling multiple studies to be carried out on the same ensemble of ions. 5 figs.

  20. Distinguishing of Ile/Leu amino acid residues in the PP3 protein by (hot) electron capture dissociation in Fourier transform ion cyclotron resonance mass spectrometry

    DEFF Research Database (Denmark)

    Kjeldsen, Frank; Haselmann, Kim F; Sørensen, Esben Skipper

    2003-01-01

    In hot electron capture dissociation (HECD), multiply protonated polypeptides fragment upon capturing approximately 11-eV electrons. The excess of energy upon the primary c, z* cleavage induces secondary fragmentation in z* fragments. The resultant w ions allow one to distinguish between the isom...

  1. Cyclotron instabilities driven by temperature anisotropy in the solar wind

    Science.gov (United States)

    Noreen, N.; Yoon, P. H.; Zaheer, S.

    2017-10-01

    Kinetic plasma instabilities are important for regulating the temperature anisotropies of electrons and ions in solar wind. For the low beta regime, it is known that electromagnetic ion/electron cyclotron instabilities are important, but in the literature these unstable modes are discussed under the assumption of parallel propagation. The present paper extends the analysis to two (or with cylindrical symmetry, three) dimensions. The analysis is further extended to include quasilinear description with the assumption of the bi-Maxwellian velocity distribution function. Such an analysis lays the foundation for an eventual study in which cyclotron instabilities as well as obliquely propagating unstable modes such as the mirror instability are simultaneously taken into account. The present paper first lays down the basis for such future efforts in which the two- or three dimensional linear and quasilinear theories of cyclotron instabilities in the low beta regime are formulated.

  2. Ion Cyclotron Resonance Facility (ICR)

    Data.gov (United States)

    Federal Laboratory Consortium — his facility is charged with developing and exploiting the unique capabilities of Fourier Transform Ion Cyclotron Resonance (FT-ICR) mass spectrometry, and leads the...

  3. BEST medical radioisotope production cyclotrons

    Energy Technology Data Exchange (ETDEWEB)

    Sabaiduc, Vasile; Milton, Bruce; Suthanthiran, Krishnan; Johnson, Richard R. [Best Cyclotron Systems Inc., 7-8765 Ash Street, Vancouver, British Columbia, V6P 6T3 (Canada); Gelbart, W. Z. [Advanced System Designs Inc., 5295 Bear Bay Road, Garden Bay, BC, V0N 1S1 (Canada)

    2013-04-19

    Best Cyclotron Systems Inc (BCSI) is currently developing 14 MeV, 25 MeV, 35MeV and 70MeV cyclotrons for radioisotope production and research applications as well as the entire spectrum of targets and nuclear synthesis modules for the production of Positron Emission Tomography (PET), Single Photon Emission Computed Tomography (SPECT) and radiation therapy isotopes. The company is a subsidiary of Best Medical International, renowned in the field of medical instrumentation and radiation therapy. All cyclotrons have external negative hydrogen ion sources, four radial sectors with two dees in opposite valleys, cryogenic vacuum system and simultaneous beam extraction on opposite lines. The beam intensity ranges from 400 {mu}A to 1000 {mu}A, depending on the cyclotron energy and application.

  4. Atomic and electronic structure transformations of silver nanoparticles under rapid cooling conditions

    OpenAIRE

    Lobato, I.; Rojas, J.; Landauro, C.V.; Torres, J

    2008-01-01

    The structural evolution and dynamics of silver nanodrops Ag${}_{2896}$ (4.4 nm in diameter) during rapid cooling conditions has been studied by means of molecular dynamics simulations and electronic density of state calculations. The interaction of silver atoms is modeled by a tight-binding semiempirical interatomic potential proposed by Cleri and Rosato. The pair correlation functions and the pair analysis technique is applied to reveal the structural transition in the process of solidifica...

  5. A Rapid Detection of Meat Spoilage using an Electronic Nose and Fuzzy-Wavelet systems

    OpenAIRE

    Kodogiannis, V.

    2018-01-01

    Freshness and safety of muscle foods are generally considered as the most important parameters for the food industry. To address the rapid detection of meat spoilage microorganisms during aerobic or modified atmosphere storage, an electronic nose with the aid of fuzzy wavelet network has been considered in this research. The proposed model incorporates a clustering pre-processing stage for the definition of fuzzy rules. The dual purpose of the proposed modelling approach is not only to classi...

  6. Cyclotron for Beam Therapy Application

    CERN Document Server

    Alenitsky, Yu G; Karamysheva, G A; Kostromin, S A; Mitsyn, G V; Molokanov, A G; Onishchenko, L M; Samsonov, E V; Vorozhtsov, S B; Zaplatin, N L

    2005-01-01

    The basic parameters of the proton isochronous cyclotron on the fixed energy are considered. The energy of protons is $E_{p}\\sim $ 220~MeV, intensity of the extracted beam is $I_{p}\\sim $ 0.1~$\\mu$A. The cyclotron is projected on the basis of compact magnet with four sectors and the diameter of poles 300 cm. Two dees of the accelerating system are located in valleys.

  7. Generation of multi-charged high current ion beams using the SMIS 37 gas-dynamic electron cyclotron resonance (ECR) ion source

    Energy Technology Data Exchange (ETDEWEB)

    Dorf, M. A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Zorin, V. G. [Russian Academy of Sciences (RAS), Nizhny Novgorod (Russian Federation). Inst. of Applied Physics; Sidorov, A. V. [Russian Academy of Sciences (RAS), Nizhny Novgorod (Russian Federation). Inst. of Applied Physics; Bokhanov, A. F. [Russian Academy of Sciences (RAS), Nizhny Novgorod (Russian Federation). Inst. of Applied Physics; Izotov, I. V. [Russian Academy of Sciences (RAS), Nizhny Novgorod (Russian Federation). Inst. of Applied Physics; Razin, S. V. [Russian Academy of Sciences (RAS), Nizhny Novgorod (Russian Federation). Inst. of Applied Physics; Skalyga, V. A. [Russian Academy of Sciences (RAS), Nizhny Novgorod (Russian Federation). Inst. of Applied Physics

    2013-06-02

    A gas-dynamic ECR ion source (GaDIS) is distinguished by its ability to produce high current and high brightness beams of moderately charged ions. Contrary to a classical ECR ion source where the plasma confinement is determined by the slow electron scattering into an empty loss-cone, the higher density and lower electron temperature in a GaDIS plasma lead to an isotropic electron distribution with the confinement time determined by the prompt gas-dynamic flow losses. As a result, much higher ion fluxes are available, however a decrease in the confinement time of the GaDIS plasma lowers the ion charge state. The gas-dynamic ECR ion source concept has been successfully realized in the SMIS 37 experimental facility operated at the Institute of Applied Physics, Russia. The use of high-power (~100 kW) microwave (37.5 GHz) radiation provides a dense plasma (~1013 cm-3) with a relatively low electron temperature (~50- 100 eV) and allows for the generation of high current (~1 A/cm2) beams of multi-charged ions. In this work we report on the present status of the SMIS 37 ion source and discuss the advanced numerical modeling of ion beam extraction using the particle-in-cell code WARP

  8. Multicavity proton cyclotron accelerator

    Directory of Open Access Journals (Sweden)

    J. L. Hirshfield

    2002-08-01

    Full Text Available A mechanism for acceleration of protons is described, in which energy gain occurs near cyclotron resonance as protons drift through a sequence of rotating-mode TE_{111} cylindrical cavities in a strong nearly uniform axial magnetic field. Cavity resonance frequencies decrease in sequence from one another with a fixed frequency interval Δf between cavities, so that synchronism can be maintained between the rf fields and proton bunches injected at intervals of 1/Δf. An example is presented in which a 122 mA, 1 MeV proton beam is accelerated to 961 MeV using a cascade of eight cavities in an 8.1 T magnetic field, with the first cavity resonant at 120 MHz and with Δf=8 MHz. Average acceleration gradient exceeds 40 MV/m, average effective shunt impedance is 223 MΩ/m, but maximum surface field in the cavities does not exceed 7.2 MV/m. These features occur because protons make many orbital turns in each cavity and thus experience acceleration from each cavity field many times. Longitudinal and transverse stability appear to be intrinsic properties of the acceleration mechanism, and an example to illustrate this is presented. This acceleration concept could be developed into a proton accelerator for a high-power neutron spallation source, such as that required for transmutation of nuclear waste or driving a subcritical fission burner, provided a number of significant practical issues can be addressed.

  9. Relativistic Cyclotron Resonance Shape in Magnetic Bottle Geonium

    Science.gov (United States)

    Dehmelt, Hans; Mittleman, Richard; Liu, Yuan

    1988-10-01

    The thermally excited axial oscillation of the electron through the weak magnetic bottle needed for the continuous Stern-Gerlach effect modulates the cyclotron frequency and produces a characteristic ≈ 12-kHz-wide vertical rise-exponential decline line shape of the cyclotron resonance. At the same time the relativistic mass shift decreases the frequency by ≈ 200 Hz per cyclotron motion quantum level n. Nevertheless, our analysis of the complex line shape shows that it should be possible to produce an abrupt rise in the cyclotron quantum number n from 0 to ≈ 20 over a small fraction of 200 Hz, when the 160-GHz microwave drive approaches the n = 0 → 1 transition, and a jump of 14 levels over a frequency increment of 200 Hz has already been observed in preliminary work. This realizes an earlier proposal to generate a very sharp cyclotron resonance feature by quasithermal excitation with a square noise band and should provide a way to detect spin flips when a weak bottle is used to reduce the broadening of the g - 2 resonance by a factor of 20.

  10. Magnetic Alfvén‐cyclotron fluctuations of anisotropic nonthermal plasmas

    National Research Council Canada - National Science Library

    Navarro, Roberto E; Muñoz, Víctor; Araneda, Jaime; Viñas, Adolfo F.‐; Moya, Pablo S; Valdivia, Juan A

    2015-01-01

    .... Here we study magnetic Alfvén‐cyclotron fluctuations propagating along a background magnetic field in a plasma composed of thermal and suprathermal protons and electrons via the fluctuation...

  11. Quantifying Extremely Rapid Flux Enhancements of Radiation Belt Relativistic Electrons Associated With Radial Diffusion

    Science.gov (United States)

    Liu, Si; Yan, Qi; Yang, Chang; Zhou, Qinghua; He, Zhaoguo; He, Yihua; Gao, Zhonglei; Xiao, Fuliang

    2018-02-01

    Previous studies have revealed a typical picture that seed electrons are transported inward under the drive of radial diffusion and then accelerated via chorus to relativistic energies. Here we show a potentially different process during the 2-3 October 2013 storm when Van Allen Probes observed extremely rapid (by about 50 times in 2 h) flux enhancements of relativistic (1.8-3.4 MeV) electrons but without distinct chorus at lower L-shells. Meanwhile, Time History of Events and Macroscale Interactions during Substorms satellites simultaneously measured enhanced chorus and fluxes of energetic (˜100-300 keV) seed electrons at higher L-shells. Numerical calculations show that chorus can efficiently accelerate seed electrons at L ˜ 8.3. Then radial diffusion further increased the phase space density of relativistic electrons throughout the outer radiation belts, with a remarkable agreement with the observation in magnitude and timescale. The current results provide a different physical scenario on the interplay between radial diffusion and local acceleration in outer radiation belt.

  12. Imaging thiol redox status in murine tumors in vivo with rapid-scan electron paramagnetic resonance

    Science.gov (United States)

    Epel, Boris; Sundramoorthy, Subramanian V.; Krzykawska-Serda, Martyna; Maggio, Matthew C.; Tseytlin, Mark; Eaton, Gareth R.; Eaton, Sandra S.; Rosen, Gerald M.; Kao, Joseph P. Y.; Halpern, Howard J.

    2017-03-01

    Thiol redox status is an important physiologic parameter that affects the success or failure of cancer treatment. Rapid scan electron paramagnetic resonance (RS EPR) is a novel technique that has shown higher signal-to-noise ratio than conventional continuous-wave EPR in in vitro studies. Here we used RS EPR to acquire rapid three-dimensional images of the thiol redox status of tumors in living mice. This work presents, for the first time, in vivo RS EPR images of the kinetics of the reaction of 2H,15N-substituted disulfide-linked dinitroxide (PxSSPx) spin probe with intracellular glutathione. The cleavage rate is proportional to the intracellular glutathione concentration. Feasibility was demonstrated in a FSa fibrosarcoma tumor model in C3H mice. Similar to other in vivo and cell model studies, decreasing intracellular glutathione concentration by treating mice with L-buthionine sulfoximine (BSO) markedly altered the kinetic images.

  13. Rapid and Versatile Photonic Annealing of Graphene Inks for Flexible Printed Electronics.

    Science.gov (United States)

    Secor, Ethan B; Ahn, Bok Y; Gao, Theodore Z; Lewis, Jennifer A; Hersam, Mark C

    2015-11-01

    Intense pulsed light (IPL) annealing of graphene inks is demonstrated for rapid post-processing of inkjet-printed patterns on various substrates. A conductivity of ≈25,000 S m(-1) is achieved following a single printing pass using a concentrated ink containing 20 mg mL(-1) graphene, establishing this strategy as a practical and effective approach for the versatile and high-performance integration of graphene in printed and flexible electronics. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Observation of cyclotron resonance and electron-phonon coupling in surface states of the bulk-insulating topological insulator Cu0.02Bi2Se3

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Liang [Johns Hopkins Univ., Baltimore, MD (United States). The Inst. of Quantum Matter; Tse, Wang-Kong [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Morris, C. M. [Johns Hopkins Univ., Baltimore, MD (United States). The Inst. of Quantum Matter; Brahlek, M. [Rutgers Univ., Piscataway, NJ (United States). Dept. of Physics and Astronomy; Koirala, N. [Rutgers Univ., Piscataway, NJ (United States). Dept. of Physics and Astronomy; Oh, S. [Rutgers Univ., Piscataway, NJ (United States). Dept. of Physics and Astronomy; Armitage, N. P. [Johns Hopkins Univ., Baltimore, MD (United States). The Inst. of Quantum Matter

    2015-02-05

    We have utilized magneto-optical time-domain spectroscopy to investigate the low frequency optical response of topological insulator Cu0.02Bi2Se3 and Bi2Se3 films. With both field and frequency depedence, such experiments give sufficient information to measure the mobility and carrier density of multiple conduction channels simultaneously. We observe sharp cyclotron resonances (CRs) in both samples. The small amount of Cu substitution into the Cu0.02Bi2Se3 induces a true bulk insulator with only a single conduction channel with total sheet carrier density 4.9 x 1012/cm2 and mobility as large as 4000 cm2/V s. This is consistent with pure topological surface state (TSSs) conduction with a chemical potential 150 meV above the Dirac point. Hence, a true topological insulator with an insulating bulk is realized. The CR broadens at high fields, an e ect that we attribute to an electron-phonon interaction. This assignment is supported by an extended Drude model analysis on the zero field data. In contrast to Cu0.02Bi2Se3, two charge channels were observed in normal Bi2Se3 films. We demonstrate a method to distinguish between the dominant TSSs and trivial bulk/2DEG states. The dominant channel exhibits a CR with a carrier density of ~2.0 x 1013/cm2 and mobility ~3200 cm2/V s, consistent with TSSs with a chemical potential ~350meV above the Dirac point.

  15. Rapid assessment of quality of deer antler slices by using an electronic nose coupled with chemometric analysis

    Directory of Open Access Journals (Sweden)

    Guojie Xu

    Full Text Available Deer antler is a precious animal-sourced traditional Chinese medicine. We aimed to rapidly assess the quality of deer antler slices by electronic nose so that we can ensure medical safety. In this study, response intensity of the electronic nose was favorably optimized, and samples were well assessed by using an electronic nose based on LDA model. The results obtained herein suggested that electronic nose could be an effective method to rapidly assess the quality of deer antler slices, and could also be an important tool for categorization of complex aroma mixtures for the control of quality of drugs or food.

  16. Design and fabrication of a superconducting magnet for an 18 GHz electron cyclotron resonance ion∕photon source NFRI-ECRIPS.

    Science.gov (United States)

    You, H-J; Jang, S-W; Jung, Y-H; Lho, T-H; Lee, S-J

    2012-02-01

    A superconducting magnet was designed and fabricated for an 18 GHz ECR ion∕photon source, which will be installed at National Fusion Research Institute (NFRI) in South Korea. The magnetic system consists of a set of four superconducting coils for axial mirror field and 36 pieces of permanent magnets for hexapolar field. The superconducting coils with a cryocooler (1.5 W @ 4.2 K) allow one to reach peak mirror fields of 2.2 T in the injection and those of 1.5 T in the extraction regions on the source axis, and the resultant hexapolar field gives 1.35 T on the plasma chamber wall. The unbalanced magnetic force between the coils and surrounding yoke has been minimized to 16 ton by a coil arrangement and their electrical connection, and then was successfully suspended by 12 strong thermal insulating supports made of large numbers of carbon fibers. In order to block radiative thermal losses, multilayer thermal insulations are covered on the coil windings as well as 40-K aluminum thermal shield. Also new schemes of quench detection and safety system (coil divisions, quench detection coils, and heaters) were employed. For impregnation of the windings a special epoxy has been selected and treated to have a higher breaking strength and a higher thermal conductivity, which enables the superconductors to be uniformly and rapidly cooled down or heated during a quench.

  17. A comparison of different silver inks for printing of conductive tracks on paper substrates for rapid prototyping of electronic circuits

    CSIR Research Space (South Africa)

    Bezuidenhout, PH

    2015-11-01

    Full Text Available of the selection process of different conductive inks for printing onto paper substrates. These results can be utilized in the development process for fully printable rapidly prototyped electronic systems, which can range from environmental sensing solutions...

  18. MC-50 AVF cyclotron operation

    Energy Technology Data Exchange (ETDEWEB)

    Chae, Jong Seo; Lee, Dong Hoon; Kim, You Seok; Park, Chan Won; Lee, Yong Min; Hong, Sung Seok; Lee, Min Yong

    1995-12-01

    The first cyclotron in Korea, MC-59 cyclotron is used for neutron irradiation, radionuclide development, production and material and biomedical research. 50.5MeV and 35MeV proton beam have been extracted with 20-70 .mu.A. A total of beam extraction time are 1095.7 hours. 206.5 hours are used for the developments and 663.8 hours are for radionuclide production and development and 225.4 hours for application researches. The shutdown days are 23days. Fundamental data for failure decrement and efficient beam extraction were composed and maintenance technologies were developed. (author). 8 tabs., 17 figs., 10 refs.

  19. MC-50 AVF cyclotron operation

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yu Seok; Chai, Jong Seo; Bak, Seong Ki; Park, Chan Won; Jo, Young Ho; Hong, Seong Seok; Lee, Min Yong; Jang Ho Ha

    2000-01-01

    The first cyclotron in Korea, MC-50 cyclotron is used for neutron irradiation, radionuclide development, production and material and biomedical research. 50.5MeV and 35MeV proton beam have been extracted with 20-60{mu}A. A total of beam extraction time are 1095.7 hours. 206.5 hours are used for the developments and 663.8 hours are for radionuclide production and development and 225.4 hours for application researches. The shutdown days are 23 days. Fundamental data for failure decrement and efficient beam extraction were composed and maintenance technologies were developed.

  20. Cyclotron transitions of bound ions

    Science.gov (United States)

    Bezchastnov, Victor G.; Pavlov, George G.

    2017-06-01

    A charged particle in a magnetic field possesses discrete energy levels associated with particle rotation around the field lines. The radiative transitions between these levels are the well-known cyclotron transitions. We show that a bound complex of particles with a nonzero net charge displays analogous transitions between the states of confined motion of the entire complex in the field. The latter bound-ion cyclotron transitions are affected by a coupling between the collective and internal motions of the complex and, as a result, differ from the transitions of a "reference" bare ion with the same mass and charge. We analyze the cyclotron transitions for complex ions by including the coupling within a rigorous quantum approach. Particular attention is paid to comparison of the transition energies and oscillator strengths to those of the bare ion. Selection rules based on integrals of collective motion are derived for the bound-ion cyclotron transitions analytically, and the perturbation and coupled-channel approaches are developed to study the transitions quantitatively. Representative examples are considered and discussed for positive and negative atomic and cluster ions.

  1. Reduction of axial kinetic energy induced perturbations on observed cyclotron frequency.

    Science.gov (United States)

    Kaiser, Nathan K; Weisbrod, Chad R; Webb, Brian N; Bruce, James E

    2008-04-01

    With Fourier transform ion cyclotron resonance (FTICR) mass spectrometry one determines the mass-to-charge ratio of an ion by measuring its cyclotron frequency. However, the need to confine ions to the trapping region of the ion cyclotron resonance (ICR) cell with electric fields induces deviations from the unperturbed cyclotron frequency. Additional perturbations to the observed cyclotron frequency are often attributed to changes in space charge conditions. This study presents a detailed investigation of the observed ion cyclotron frequency as a function of ion z-axis kinetic energy. In a perfect three-dimensional quadrupolar field, cyclotron frequency is independent of position within the trap. However, in most ICR cell designs, this ideality is approximated only near the trap center and deviations arise from this ideal quadrupolar field as the ion moves both radially and axially from the center of the trap. To allow differentiation between deviations in observed cyclotron frequency caused from changes in space charge conditions or differences in oscillation amplitude, ions with identical molecular weights but different axial kinetic energy, and thus amplitude of z-axis motion, were simultaneously trapped within the ICR cell. This allows one to attribute deviations in observed cyclotron frequency to differences in the average force from the radial electric field experienced by ions of different axial amplitude. Experimentally derived magnetron frequency is compared with the magnetron frequency calculated using SIMION 7.0 for ions of different axial amplitude. Electron promoted ion coherence, or EPIC, is used to reduce the differences in radial electric fields at different axial positions. Thus with the application of EPIC, the differences in observed cyclotron frequencies are minimized for ions of different axial oscillation amplitudes.

  2. Application of a voltammetric electronic tongue and near infrared spectroscopy for a rapid umami taste assessment.

    Science.gov (United States)

    Bagnasco, Lucia; Cosulich, M Elisabetta; Speranza, Giovanna; Medini, Luca; Oliveri, Paolo; Lanteri, Silvia

    2014-08-15

    The relationships between sensory attribute and analytical measurements, performed by electronic tongue (ET) and near-infrared spectroscopy (NIRS), were investigated in order to develop a rapid method for the assessment of umami taste. Commercially available umami products and some aminoacids were submitted to sensory analysis. Results were analysed in comparison with the outcomes of analytical measurements. Multivariate exploratory analysis was performed by principal component analysis (PCA). Calibration models for prediction of the umami taste on the basis of ET and NIR signals were obtained using partial least squares (PLS) regression. Different approaches for merging data from the two different analytical instruments were considered. Both of the techniques demonstrated to provide information related with umami taste. In particular, ET signals showed the higher correlation with umami attribute. Data fusion was found to be slightly beneficial - not so significantly as to justify the coupled use of the two analytical techniques. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Electronic vending machines for dispensing rapid HIV self-testing kits: a case study.

    Science.gov (United States)

    Young, Sean D; Klausner, Jeffrey; Fynn, Risa; Bolan, Robert

    2014-02-01

    This short report evaluates the feasibility of using electronic vending machines for dispensing oral, fluid, rapid HIV self-testing kits in Los Angeles County. Feasibility criteria that needed to be addressed were defined as: (1) ability to find a manufacturer who would allow dispensing of HIV testing kits and could fit them to the dimensions of a vending machine, (2) ability to identify and address potential initial obstacles, trade-offs in choosing a machine location, and (3) ability to gain community approval for implementing this approach in a community setting. To address these issues, we contracted a vending machine company who could supply a customized, Internet-enabled machine that could dispense HIV kits and partnered with a local health center available to host the machine onsite and provide counseling to participants, if needed. Vending machines appear to be feasible technologies that can be used to distribute HIV testing kits.

  4. Optically detected cyclotron resonance in a single GaAs/AlGaAs heterojunction

    Energy Technology Data Exchange (ETDEWEB)

    Bartsch, Gregor

    2011-09-23

    Optically detected far-infrared cyclotron resonance (FIR-ODCR) in GaAs/AlGaAs HJs is interpreted in the frame of an exciton-dissociation mechanism. It is possible to explain the ODR mechanism by an exciton drag, mediated by ballistically propagating phonons. Furthermore, very narrow resonances are presented and realistic electron mobility values can be calculated. The exceptionally narrow ODCRs allow to measure conduction-band nonparabolicity effects and resolve satellite resonances, close to the main cyclotron resonance line.

  5. Symmetry Properties of Proton Velocity Distributions: a Vlasov Simulation Study of the Ion Cyclotron Instability

    Science.gov (United States)

    Araneda, J. A.; López, R. A.; Vinas, A. F.

    2014-12-01

    The ion cyclotron instability is driven by a sufficiently large proton temperature anisotropy, generating a spectrum of counterpropagating field-aligned ion cyclotron fluctuations. In this work, we use low-noise one-dimensional electromagnetic Vlasov simulations in a magnetized and collisionless plasma of fluid electrons and one ion species to study the evolution of proton velocity distributions during the thermal relaxation process. Special attention is given to deviations from initial bi-Maxwellian shapes.

  6. Rapid increase of near atomic resolution virus capsid structures determined by cryo-electron microscopy.

    Science.gov (United States)

    Ho, Phuong T; Reddy, Vijay S

    2017-10-27

    The recent technological advances in electron microscopes, detectors, as well as image processing and reconstruction software have brought single particle cryo-electron microscopy (cryo-EM) into prominence for determining structures of bio-molecules at near atomic resolution. This has been particularly true for virus capsids, ribosomes, and other large assemblies, which have been the ideal specimens for structural studies by cryo-EM approaches. An analysis of time series metadata of virus structures on the methods of structure determination, resolution of the structures, and size of the virus particles revealed a rapid increase in the virus structures determined by cryo-EM at near atomic resolution since 2010. In addition, the data highlight the median resolution (∼3.0 Å) and size (∼310.0 Å in diameter) of the virus particles determined by X-ray crystallography while no such limits exist for cryo-EM structures, which have a median diameter of 508 Å. Notably, cryo-EM virus structures in the last four years have a median resolution of 3.9 Å. Taken together with minimal sample requirements, not needing diffraction quality crystals, and being able to achieve similar resolutions of the crystal structures makes cryo-EM the method of choice for current and future virus capsid structure determinations. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. The exothermic reaction route of a self-heatable conductive ink for rapid processable printed electronics.

    Science.gov (United States)

    Shin, Dong-Youn; Han, Jin Wook; Chun, Sangki

    2014-01-07

    We report the exothermic reaction route and new capability of a self-heatable conductive ink (Ag2O and silver 2,2-dimethyloctanoate) in order to achieve both a low sintering temperature and electrical resistivity within a short sintering time for flexible printed electronics and display appliances. Unlike conventional conductive ink, which requires a costly external heating instrument for rapid sintering, self-heatable conductive ink by itself is capable of generating heat as high as 312 °C when its exothermic reaction is triggered at a temperature of 180 °C. This intensive exothermic reaction is found to result from the recursive reaction of the 2,2-dimethyloctanoate anion, which is thermally dissociated from silver 2,2-dimethyloctanoate, with silver oxide microparticles. Through this recursive reaction, a massive number of silver atoms are supplied from silver oxide microparticles, and the nucleation of silver atoms and the fusion of silver nanoparticles become the major source of heat. This exothermic reaction eventually realizes the electrical resistivity of self-heatable conductive ink as low as 27.5 μΩ cm within just 40 s by combining chemical annealing, which makes it suitable for the roll-to-roll printable electronics such as a flexible touch screen panel.

  8. Atomic and electronic structure transformations of silver nanoparticles under rapid cooling conditions.

    Science.gov (United States)

    Lobato, I; Rojas, J; Landauro, C V; Torres, J

    2009-02-04

    The structural evolution and dynamics of silver nanodrops Ag(2869) (4.4 nm in diameter) under rapid cooling conditions have been studied by means of molecular dynamics simulations and electronic density of state calculations. The interaction of silver atoms is modelled by a tight-binding semiempirical interatomic potential proposed by Cleri and Rosato. The pair correlation functions and the pair analysis technique are used to reveal the structural transition in the process of solidification. It is shown that Ag nanoparticles evolve into different nanostructures under different cooling processes. At a cooling rate of 1.5625 × 10(13) K s(-1) the nanoparticles preserve an amorphous-like structure containing a large amount of 1551 and 1541 pairs which correspond to icosahedral symmetry. For a lower cooling rate (1.5625 × 10(12) K s(-1)), the nanoparticles transform into a crystal-like structure consisting mainly of 1421 and 1422 pairs which correspond to the face centred cubic and hexagonal close packed structures, respectively. The variations of the electronic density of states for the differently cooled nanoparticles are small, but in correspondence with the structural changes.

  9. Microwave power coupling with electron cyclotron resonance ...

    Indian Academy of Sciences (India)

    The effect of microwave power coupling to the plasma was studied by varying the microwave power. ... plasma is produced by the interaction of microwave radiation, in the presence of appro- priate magnetic field ... microwaves are used in resonant mode to couple the electromagnetic energy to the plasma for generating ...

  10. Absorption and emission of extraordinary-mode electromagnetic waves near cyclotron frequency in nonequilibrium plasmas

    Science.gov (United States)

    Wu, C. S.; Lin, C. S.; Wong, H. K.; Tsai, S. T.; Zhou, R. L.

    1981-01-01

    An investigation is presented of two cases: (1) weakly relativistic electrons with a loss-cone type distribution, and (2) electrons with a drift velocity parallel to the ambient magnetic field. Numerical computations are given for physical parameters close to those in the polar region of the earth magnetosphere and laboratory experiments, with attention to the fast extraordinary-mode radiation whose frequency is near that of the electron cyclotron frequency. The fast extraordinary mode can escape from a strong field region to the weaker field region and may therefore be measured outside the plasma. It is found that the X mode radiation can be amplified by means of a cyclotron maser effect when the electrons have a loss-cone distribution, and it is concluded that, when the electron energy is sufficiently high, the X mode cutoff frequency may be lower than the cyclotron frequency.

  11. TRIUMF cyclotron vacuum system refurbishing

    Science.gov (United States)

    Sekachev, I.

    2008-03-01

    The cyclotron at TRIUMF was commissioned to full energy in 1974. The volume of the cyclotron vacuum tank is about 100 m3 and it operates at 5×10-8 Torr pressure during beam production. The pumping is mainly based on a Phillips B-20 cryogenerator (Stirling cycle 4-cylinder engine). The cryogenerator supplies helium gas at 16 K and 70 K to cryopanels in the tank. The decreasing reliability of the B-20 and demanding maintenance requirements triggered the decision to completely overhaul or replace the cryogenerator. Replacement with the LINDE-1630 helium refrigerator was found to be the most attractive (technically and economically) option. The details of the proposal with installation of the helium refrigerator and with a continuous flow liquid nitrogen shield cooling system are presented.

  12. The development of cyclotron radiopharmaceuticals

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Seung Dae; Chun, K. W.; Suh, Y. S.; Lee, J. D.; Ahn, S. H. and others

    1999-03-01

    The purpose of this project is to developthe radiopharmaceuticals and automatic synthetic unit for labelled compounds, and to establish mass production system of radiopharmaceuticals. These will contribute to the early diagnosis of the disease hard to cure. The contents of this project are as follows, the development of the radiopharmaceutical for imaging of cancer, the development of automatic synthesizer for the synthesis of radio-pharmaceuticals, the development of hormone derivatives labelled with {sup 12}'3I, the development of the radiopharmaceuticals for therapy of cancer labelled with cyclotron produced radionuclides, the development of radiopharmaceuticals for therapy of cancer labelled with cyclotron produced radionuclides, the development of radiopharmaceuticals for imaging of myocardial metabolism.

  13. Cyclotron Auto-Resonance Accelerator for environmental applications

    Science.gov (United States)

    Jiang, Yong; Shchelkunov, Sergey V.; Hirshfield, Jay L.

    2017-03-01

    A MW-level CW electron beam source for environmental remediation based on extensions of the scientifically-proven Cyclotron Auto-Resonance Accelerator, dubbed CARA, is described here. CARA is distinguished by its exceptionally high RF-to-beam efficiency, by its production of a self-scanning beam, and by its proportionately lower specific power loading on a beam output window. Its environmental applications include sterilization, flue gas and waste water treatment.

  14. Determination of electromagnetic modes in oversized corrugated waveguides on the electron cyclotron resonance heating installation at the tokamak Tore Supra; Determination de modes electromagnetiques de guides d'ondes corrugues surdimensionnes sur l'installation de chauffage des electrons de tokamak Tore Supra

    Energy Technology Data Exchange (ETDEWEB)

    Courtois, L

    2001-03-09

    Electron cyclotron resonance heating (ECRH) in the Tore Supra tokamak constitutes an important step in the research aimed at obtaining thermonuclear fusion reactions. Electron heating is achieved by transmitting an electromagnetic wave from the oscillators (gyrotrons) to the plasma via the fundamental mode, propagating in oversized corrugated waveguides. Maximizing the proportion of the gyrotron power coupled to the fundamental waveguide mode is essential for the good functioning of the transmission line and for maximizing the effect on the plasma. This thesis gives all necessary tools for finding the proportion of the fundamental mode and all other modes present in passive components and at the output of the gyrotron as installed in the Tore Supra ECRH plant. This characterisation is based on obtaining amplitude and phase diagrams of the electric field on a plane transverse to the propagation axis. The most difficult part of obtaining these diagrams is measuring the phase which, despite the very short wavelength, is measured directly at low power levels. At high power levels the phase is numerically reconstructed from amplitude measurements for gyrotron characterisation. A complete theoretical study of the phase reconstruction code is given including its validation with theoretical diagrams. This study allows the realisation of a modal characterisation unit electromagnetic for measurement of radiated beams and usable in each part of the ECRH installation. At the end, the complete modal characterisation is given at low level for a mode converter and also at high level for the first series gyrotron installed at TORE SUPRA. (author)

  15. Method and apparatus for ion cyclotron spectrometry

    Science.gov (United States)

    Dahl, David A [Idaho Falls, ID; Scott, Jill R [Idaho Falls, ID; McJunkin, Timothy R [Idaho Falls, ID

    2010-08-17

    An ion cyclotron spectrometer may include a vacuum chamber that extends at least along a z-axis and means for producing a magnetic field within the vacuum chamber so that a magnetic field vector is generally parallel to the z-axis. The ion cyclotron spectrometer may also include means for producing a trapping electric field within the vacuum chamber that includes at least a first section that induces a first magnetron effect that increases a cyclotron frequency of an ion and at least a second section that induces a second magnetron effect that decreases the cyclotron frequency of an ion. The cyclotron frequency changes induced by the first and second magnetron effects substantially cancel one another so that an ion traversing the at least first and second sections will experience no net change in cyclotron frequency.

  16. Ammonia-treated N-(1-naphthyl) ethylenediamine dihydrochloride as a novel matrix for rapid quantitative and qualitative determination of serum free fatty acids by matrix-assisted laser desorption/ionization-Fourier transform ion cyclotron resonance mass spectrometry.

    Science.gov (United States)

    Zhang, Yaping; Wang, Yanmin; Guo, Shuai; Guo, Yumei; Liu, Hui; Li, Zhili

    2013-09-10

    The blood free fatty acids (FFAs), which provide energy to the cell and act as substrates in the synthesis of fats, lipoproteins, liposaccharides, and eicosanoids, involve in a number of important physiological processes. In the present study, matrix-assisted laser desorption/ionization-Fourier transform ion cyclotron resonance mass spectrometry (MALDI-FTICR MS) with ammonia-treated N-(1-naphthyl) ethylenediamine dihydrochloride (ATNEDC) as a novel MALDI matrix in a negative ion mode was employed to directly quantify serum FFAs. Multiple point internal standard calibration curves between the concentration ratios of individual fatty acids to internal standard (IS, C17:0) versus their corresponding intensity ratios were constructed for C14:0, C16:1, C16:0, C18:0, C18:1, C18:2, C18:3, C20:4, and C22:6, respectively, in their mixture, with correlation coefficients between 0.991 and 0.999 and limits of detection (LODs) between 0.2 and 5.4μM, along with the linear dynamic range of more than two orders of magnitude. The results indicate that the multiple point internal standard calibration could reduce the impact of ion suppression and improve quantification accuracy in the MALDI mode. The quantitative results of nine FFAs from 339 serum samples, including 161 healthy controls, 118 patients with hyperglycemia and 60 patients without hyperglycemia show that FFAs levels in hyperglycemic patient sera are significantly higher than those in healthy controls and patients without hyperglycemia, and elevated FFA levels are also associated with increased levels of fasting blood glucose (FBG) in hyperglycemic patient sera. Serum FFAs were identified on the basis of the observed accurate molecular masses and reliable isotope distributions obtained by MALDI-FTICR MS. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. Rapid fabrication of Al{sub 2}O{sub 3} encapsulations for organic electronic devices

    Energy Technology Data Exchange (ETDEWEB)

    Ali, Kamran; Ali, Junaid [Department of Mechatronics Engineering, Jeju National University, Jeju 690-756 (Korea, Republic of); Mehdi, Syed Murtuza [Department of Mechanical Engineering, NED University of Engineering and Technology, Karachi 75270 (Pakistan); Choi, Kyung-Hyun, E-mail: amm@jejunu.ac.kr [Department of Mechatronics Engineering, Jeju National University, Jeju 690-756 (Korea, Republic of); An, Young Jin [Jeonnam Science and Technology Promotion Center, Yeongam-gun, Jeollanam-do 526-897 (Korea, Republic of)

    2015-10-30

    Highlights: • Al{sub 2}O{sub 3} encapsulations are being developed through a unique R2R-AALD system. • The encapsulations have resulted in life time enhancement of PVP memristor devices. • The Al{sub 2}O{sub 3} encapsulated memristor performed with superior stability for four weeks. • Encapsulated devices performed efficiently even after bending test for 100 cycles. - Abstract: Organic electronics have earned great reputation in electronic industry yet they suffer technical challenges such as short lifetimes and low reliability because of their susceptibility to water vapor and oxygen which causes their fast degradation. This paper report on the rapid fabrication of Al{sub 2}O{sub 3} encapsulations through a unique roll-to-roll atmospheric atomic layer deposition technology (R2R-AALD) for the life time enhancement of organic poly (4-vinylphenol) (PVP) memristor devices. The devices were then categorized into two sets. One was processed with R2R-AALD Al{sub 2}O{sub 3} encapsulations at 50 °C and the other one was kept as un-encapsulated. The field-emission scanning electron microscopy (FESEM) results revealed that pin holes and other irregularities in PVP films with average arithmetic roughness (R{sub a}) of 9.66 nm have been effectively covered by Al{sub 2}O{sub 3} encapsulation having R{sub a} of 0.92 nm. The X-ray photoelectron spectroscopy XPS spectrum for PVP film showed peaks of C 1s and O 1s at the binding energies of 285 eV and 531 eV, respectively. The respective appearance of Al 2p, Al 2s, and O 1s peaks at the binding energies of 74 eV, 119 eV, and 531 eV, confirms the fabrication of Al{sub 2}O{sub 3} films. Electrical current–voltage (I–V) measurements confirmed that the Al{sub 2}O{sub 3} encapsulation has a huge influence on the performance, robustness and life time of memristor devices. The Al{sub 2}O{sub 3} encapsulated memristor performed with superior stability for four weeks whereas the un-encapsulated devices could only last for one

  18. Holographic Spectroscopy for Rapid Electron Bunch Analysis: Development of an Instrument with THZ Resolved Optical Gating

    Energy Technology Data Exchange (ETDEWEB)

    Sievers, Albert

    2011-10-28

    radiation and provided the first step in the development of a self contained THz HFTS for rapid electron bunch shape analysis. Our first experiments confirmed the idea and as a side result made possible a completely new bunch length monitor eliminating any need for an external laser since only radiation produced by the bunch itself is involved. A more advanced instrument was designed to use the incoherent visible radiation pulse from the synchrotron source for sampling the THz interference pattern. It has been built and the first tests are to be conducted in April 2011 at the Jefferson FEL facility.

  19. Cyclotron resonance in InAs/AlSb quantum wells in magnetic fields up to 45 T

    Energy Technology Data Exchange (ETDEWEB)

    Spirin, K. E., E-mail: spirink@ipmras.ru; Krishtopenko, S. S. [Russian Academy of Sciences, Institute for Physics of Microstructures (Russian Federation); Sadofyev, Yu. G. [Russian Academy of Sciences, Lebedev Physical Institute (Russian Federation); Drachenko, O. [Laboratoire National des Champs Magn’etiques Intenses (France); Helm, M. [Forschungszentrum Dresden–Rossendorf, Dresden High-Magnetic-Field Laboratory and Institute of Ion-Beam Physics and Materials Research (Germany); Teppe, F.; Knap, W. [GIS-TERALAB Universite Montpellier II, Laboratoire Charles Coulomb UMR CNRS 5221 (L2C) (France); Gavrilenko, V. I. [Russian Academy of Sciences, Institute for Physics of Microstructures (Russian Federation)

    2015-12-15

    Electron cyclotron resonance in InAs/AlSb heterostructures with quantum wells of various widths in pulsed magnetic fields up to 45 T are investigated. Our experimental cyclotron energies are in satisfactory agreement with the results of theoretical calculations performed using the eight-band kp Hamiltonian. The shift of the cyclotron resonance (CR) line, which corresponds to the transition from the lowest Landau level to the low magnetic-field region, is found upon varying the electron concentration due to the negative persistent photoconductivity effect. It is shown that the observed shift of the CR lines is associated with the finite width of the density of states at the Landau levels.

  20. Coupling of electrostatic ion cyclotron and ion acoustic waves in the solar wind

    Energy Technology Data Exchange (ETDEWEB)

    Sreeraj, T., E-mail: sreerajt13@iigs.iigm.res.in [Indian Institute of Geomagnetism, Navi Mumbai (India); Singh, S. V., E-mail: satyavir@iigs.iigm.res.in; Lakhina, G. S., E-mail: gslakhina@gmail.com [Indian Institute of Geomagnetism, Navi Mumbai (India); University of the Western Cape, Bellville 7535, Capetown (South Africa)

    2016-08-15

    The coupling of electrostatic ion cyclotron and ion acoustic waves is examined in three component magnetized plasma consisting of electrons, protons, and alpha particles. In the theoretical model relevant to solar wind plasma, electrons are assumed to be superthermal with kappa distribution and protons as well as alpha particles follow the fluid dynamical equations. A general linear dispersion relation is derived for such a plasma system which is analyzed both analytically and numerically. For parallel propagation, electrostatic ion cyclotron (proton and helium cyclotron) and ion acoustic (slow and fast) modes are decoupled. For oblique propagation, coupling between the cyclotron and acoustic modes occurs. Furthermore, when the angle of propagation is increased, the separation between acoustic and cyclotron modes increases which is an indication of weaker coupling at large angle of propagation. For perpendicular propagation, only cyclotron modes are observed. The effect of various parameters such as number density and temperature of alpha particles and superthermality on dispersion characteristics is examined in details. The coupling between various modes occurs for small values of wavenumber.

  1. Cyclotron resonance in InAs/GaSb heterostructure in inclined magnetic field

    CERN Document Server

    Greshnov, A A; Vasilev, Yu B; Suchalkin, S D; Meltser, B Y; Ivanov, S V; Kopev, P S

    2002-01-01

    The mechanism of splitting the cyclotron resonance line in the InAs/GaSb heterostructure in the inclined magnetic field is experimentally and theoretically studied. It is shown that the electrons and holes mixing in leads to the anticrossing Landau levels and consequently to the cyclotron resonance line splitting. Splitting in the case of the inclined magnetic field was not observed which is explained by damping the electrons and holes states mixing in on the account of originating the additional barrier for the electrons and holes by availability of the magnetic field longitudinal constituent

  2. 76 FR 80982 - International Cyclotron, Inc., Hato Rey, Puerto Rico; Order Suspending Licensed Activities

    Science.gov (United States)

    2011-12-27

    ...-0292] International Cyclotron, Inc., Hato Rey, Puerto Rico; Order Suspending Licensed Activities I International Cyclotron, Inc. (International Cyclotron; Licensee) is the holder of Byproduct Materials License... International Cyclotron submitted its NRC license application related to the cyclotron, it requested...

  3. Theoretical and experimental study of cyclotronic waves in a fusion plasma; Etude theorique et experimentale des ondes cyclotroniques electroniques dans un plasma de fusion

    Energy Technology Data Exchange (ETDEWEB)

    Vezard, D.

    1994-12-20

    This thesis presents a study concerning cyclotronic waves in a plasma. It starts with an illustration of the elementary interaction between electromagnetic waves and matter.It shows that electrons from tokamak absorbs waves at cyclotronic frequency. Cyclotronic waves are studied by solving the dispersion relation in plasma; it concerns polarisation, absorption, dispersion, extinction. Then, classical theories are reminded in order to speak about decoupled electrons and their interactions. Absorption and emission properties of cyclotronic waves by electrons from a queue are described. After that, cyclotronic waves propagation is studied taking into account resonance. The last part of this thesis is dedicated to the electronic distribution function that is made by a wave spectra at a inferior hybrid frequency. (TEC). 129 refs., 75 figs.

  4. Radiation surveillance in and around cyclotron facility

    Science.gov (United States)

    Kaur, Amandeep; Sharma, Sarika; Mittal, BR

    2012-01-01

    The cyclotron is the most widely used particle accelerator for producing medically important radio nuclides. Many medical centers in India have installed compact medical cyclotrons for on-site production of short-lived positron-emitting radio nuclides such as 18F, 13N, and 11C. A mandatory requirement for cyclotron installation is radiation control permit from Atomic Energy Regulatory Board. Cyclotron radiation survey is an integral part of the overall radiation safety in the cyclotron facility. Radiation surveillance in and around a newly installed cyclotron was performed using ionization chamber counter and Geiger Muller counter before, during and after operating the cyclotron. The readings were recorded at various locations where a high radiation field was expected. The results were recorded, tabulated and analyzed. The highest exposure level (0.93 μSv) was found at the back wall of the radiochemistry lab facing the cyclotron vault. Reason for the high exposure of 0.93 μSv/h: Synthesis of 18F-Fluoro-Deoxy-Glucose (18F-FDG) was going in the synthesis module and activity (18F) was present in the synthesis module when reading was taken. All other values were found to be below the recommended levels of exposure. PMID:24019654

  5. Developing the smallest possible medical cyclotron

    CERN Multimedia

    Katarina Anthony

    2011-01-01

    Imagine a portable medical cyclotron operated in a conventional radioactive facility at a hospital. Imagine a nurse or technician switching it on and producing isotopes at the patient’s bedside. Sounds like science fiction? Think again.   CERN has teamed up with Spain’s national scientific research centre (CIEMAT) to develop an avant-garde cyclotron to be used for Positron Emission Tomography (PET). “We plan to make a cyclotron that doesn't need an insulated building or ‘vault’: a cyclotron small enough to fit inside a hospital lift,” explains Jose Manuel Perez, who is leading the CIEMAT/CERN collaboration. “It will be the smallest possible medical cyclotron for single patient dose production and will dramatically reduce costs for hospitals.” While PET technology has transformed imaging techniques, many of its medical benefits have remained confined to highly specialised hospitals. “Studies have foun...

  6. Influence of injection beam emittance on beam transmission efficiency in a cyclotron.

    Science.gov (United States)

    Kurashima, Satoshi; Kashiwagi, Hirotsugu; Miyawaki, Nobumasa; Yoshida, Ken-Ichi; Okumura, Susumu

    2014-02-01

    The JAEA AVF cyclotron accelerates various kinds of high-energy ion beams for research in biotechnology and materials science. Beam intensities of an ion species of the order of 10(-9)-10(-6) ampere are often required for various experiments performed sequentially over a day. To provide ion beams with sufficient intensity and stability, an operator has to retune an ion source in a short time. However, the beam intensity downstream of the cyclotron rarely increases in proportion to the intensity at the ion source. To understand the cause of this beam behavior, transmission efficiencies of a (12)C(5+) beam from an electron cyclotron resonance ion source to the cyclotron were measured for various conditions of the ion source. Moreover, a feasible region for acceleration in the emittance of the injection beam was clarified using a transverse-acceptance measuring system. We confirmed that the beam emittance and profile were changed depending on the condition of the ion source and that matching between the beam emittance and the acceptance of the cyclotron was degraded. However, after fine-tuning to improve the matching, beam intensity downstream of the cyclotron increased.

  7. An Educational Laboratory for Digital Control and Rapid Prototyping of Power Electronic Circuits

    Science.gov (United States)

    Choi, Sanghun; Saeedifard, M.

    2012-01-01

    This paper describes a new educational power electronics laboratory that was developed primarily to reinforce experimentally the fundamental concepts presented in a power electronics course. The developed laboratory combines theoretical design, simulation studies, digital control, fabrication, and verification of power-electronic circuits based on…

  8. Rapid Embedded Wire Heating via Resistive Guiding of Laser-Generated Fast Electrons as a Hydrodynamic Driver

    CERN Document Server

    Robinson, A P L; Pasley, J

    2014-01-01

    Resistively guiding laser-generated fast electron beams in targets consisting of a resistive wire embedded in lower $Z$ material should allow one to rapidly heat the wire to over 100eV over a substantial distance without strongly heating the surrounding material. On the multi-ps timescale this can drive hydrodynamic motion in the surrounding material. Thus ultra-intense laser solid interactions have the potential as a controlled driver of radiation hydrodynamics in solid density material. In this paper we assess the laser and target parameters needed to achieve such rapid and controlled heating of the embedded wire.

  9. Study of fast electrons from hard-X radiation; Etude des electrons rapides a partir du rayonnement X-dur

    Energy Technology Data Exchange (ETDEWEB)

    Arslanbekov, R.

    1995-12-19

    The goal of this thesis is the study of fast electron dynamics by means of the hard X-ray diagnosis installed in TORE SUPRA and numerical simulations. Fast electrons are generated in the plasma in the presence of the injected lower hybrid (LH) waves. Two aspects are studied in detail: the lower hybrid wave propagation and absorption in a periodically perturbed media and 2-D Fokker-Planck modelling of the fast electron dynamics in the presence of the LH power. Ripple effects on lower hybrid wave propagation and absorption are investigated using the ray tracing technique. A cylindrical equilibrium is first studied and a strong modification of the ray dynamics is predicted. Calculations are carried out in a real toroidal geometry corresponding to TORE SUPRA. It is shown that the lack of toroidal axisymmetry of the magnetic field may result in a modification of the ray evolution even if the global ray evolution is governed by the larger poloidal inhomogeneity. Simulation of LH experiments are performed for TORE SUPRA tokamak which has a large magnetic ripple (7% at the plasma edge). By considering ripple perturbation in LH current drive simulations, a better agreement is found with experimental results, in particular with the hard-X spectra and the current density profiles. In the second part of the thesis, a 2-D modeling of the fast electron dynamics in the velocity phase space is considered, based on the 2-D relativistic electron Fokker-Planck equation. Electron distribution functions obtained are used to calculate non-thermal Bremsstrahlung emission for different TORE SUPRA shots in a wide range of experimental conditions. (J.S.). 168 refs., 93 figs., 1 tab., 3 appendix.

  10. The electrostatic ion-cyclotron instability-a two-dimensional potential relaxation instability

    DEFF Research Database (Denmark)

    Popa, G.; Schrittwieser, R.; Juul Rasmussen, Jens

    1985-01-01

    An experimental investigation shows that the electrostatic ion-cyclotron instability, driven by an electron current to a positively biased collector, is accompanied by strong coherent two-dimensional fluctuations of the plasma potential in front of the collector. These results suggest that this i......An experimental investigation shows that the electrostatic ion-cyclotron instability, driven by an electron current to a positively biased collector, is accompanied by strong coherent two-dimensional fluctuations of the plasma potential in front of the collector. These results suggest...

  11. Survey of Saturn electrostatic cyclotron harmonic wave intensity

    Science.gov (United States)

    Menietti, J. D.; Averkamp, T. F.; Kurth, W. S.; Ye, S.-Y.; Gurnett, D. A.; Cecconi, B.

    2017-08-01

    We conduct a survey of electrostatic electron cyclotron harmonic (ECH) emissions observed at Saturn by the radio and plasma wave science investigation on board the Cassini spacecraft. These emissions are known to be effective at interacting with electrons in the terrestrial inner magnetosphere, producing electron scattering into the loss cone and acceleration (cf. Horne and Thorne, 2000; Thorne et al., 2010). At Saturn ECH emission occurs with high probability and at strong intensity near the magnetic equator, outside the Enceladus torus in the range 5 < L < 10. Inside the inner boundary of the torus, ECH emissions are also observed near the equator and at higher latitude. Intensity levels of ECH emission are comparable to those observed at Earth, higher than Saturn chorus and Z-mode emission, and are likely to scatter electrons into the loss cone as at Earth. ECH waves are particularly intense and extend to higher harmonics within some plasma injection regions. We present results for a survey of over 8 years of Saturn data for fundamental and up to three harmonics of fce, the electron cyclotron frequency.

  12. Results from the Project 8 phase-1 cyclotron radiation emission spectroscopy detector

    Science.gov (United States)

    Ashtari Esfahani, A.; Böser, S.; Claessens, C.; de Viveiros, L.; Doe, P. J.; Doeleman, S.; Fertl, M.; Finn, E. C.; Formaggio, J. A.; Guigue, M.; Heeger, K. M.; Jones, A. M.; Kazkaz, K.; LaRoque, B. H.; Machado, E.; Monreal, B.; Nikkel, J. A.; Oblath, N. S.; Robertson, R. G. H.; Rosenberg, L. J.; Rybka, G.; Saldaña, L.; Slocum, P. L.; Tedeschi, J. R.; Thümmler, T.; Vandevender, B. A.; Wachtendonk, M.; Weintroub, J.; Young, A.; Zayas, E.

    2017-09-01

    The Project 8 collaboration seeks to measure the absolute neutrino mass scale by means of precision spectroscopy of the beta decay of tritium. Our technique, cyclotron radiation emission spectroscopy, measures the frequency of the radiation emitted by electrons produced by decays in an ambient magnetic field. Because the cyclotron frequency is inversely proportional to the electron’s Lorentz factor, this is also a measurement of the electron’s energy. In order to demonstrate the viability of this technique, we have assembled and successfully operated a prototype system, which uses a rectangular waveguide to collect the cyclotron radiation from internal conversion electrons emitted from a gaseous 83m Kr source. Here we present the main design aspects of the first phase prototype, which was operated during parts of 2014 and 2015. We will also discuss the procedures used to analyze these data, along with the features which have been observed and the performance achieved to date.

  13. Lumped Parameter Modeling for Rapid Vibration Response Prototyping and Test Correlation for Electronic Units

    Science.gov (United States)

    Van Dyke, Michael B.

    2013-01-01

    Present preliminary work using lumped parameter models to approximate dynamic response of electronic units to random vibration; Derive a general N-DOF model for application to electronic units; Illustrate parametric influence of model parameters; Implication of coupled dynamics for unit/board design; Demonstrate use of model to infer printed wiring board (PWB) dynamics from external chassis test measurement.

  14. Study the Precipitation of Radiation Belt Electrons during the Rapid Dropout Events

    Science.gov (United States)

    Tu, W.; Cunningham, G.; Li, X.; Chen, Y.

    2015-12-01

    During the main phase of storms, the relativistic electron flux in the radiation belt can drop by orders of magnitude on timescales of a few hours. Where do the electrons go? This is one of the most important outstanding questions in radiation belt studies. Radiation belt electrons can be lost either by transport across the magnetopause into interplanetary space or by precipitation into the atmosphere. In this work we first conduct a survey of the MeV electron dropouts using the Van Allen Probes data in conjunction with the low-altitude measurements of precipitating electrons by 6 NOAA/POES satellites. The dropout events are categorized into three types: precipitation-loss dominant, outward radial diffusion dominant, or with contributions from both mechanisms. The survey results suggest the relative importance of precipitation and outward radial diffusion to the fast dropouts of radiation belt electrons, and their extent in L-shell and electron energy. Then, for specific events identified as dominated by precipitation loss, we use the Drift-Diffusion model, which includes the effects of azimuthal drift and pitch angle diffusion, to simulate both the electron dropout observed by Van Allen Probes and the distributions of drift-loss-cone electrons observed by multiple low-earth-orbit satellites (6 POES and the Colorado Student Space Weather Experiment). The model quantifies the electron precipitation loss and pitch angle diffusion coefficient, Dxx, with high temporal and spatial resolution. Finally, by comparing the Dxx derived from the model with those estimated from the quasi-linear theory using wave data from Van Allen Probes and other event-specific wave models, we are able to test the validity of quasi-linear theory and seek direct evidence of the wave-particle interactions during the dropouts.

  15. A rapid discrimination of authentic and unauthentic Radix Angelicae Sinensis growth regions by electronic nose coupled with multivariate statistical analyses.

    Science.gov (United States)

    Liu, Jie; Wang, Weixin; Yang, Yaojun; Yan, Yuning; Wang, Wenyi; Wu, Haozhong; Ren, Zihe

    2014-10-27

    Radix Angelicae Sinensis, known as Danggui in China, is an effective and wide applied material in Traditional Chinese Medicine (TCM) and it is used in more than 80 composite formulae. Danggui from Minxian County, Gansu Province is the best in quality. To rapidly and nondestructively discriminate Danggui from the authentic region of origin from that from an unauthentic region, an electronic nose coupled with multivariate statistical analyses was developed. Two different feature extraction methods were used to ensure the authentic region and unauthentic region of Danggui origin could be discriminated. One feature extraction method is to capture the average value of the maximum response of the electronic nose sensors (feature extraction method 1). The other one is to combine the maximum response of the sensors with their inter-ratios (feature extraction method 2). Multivariate statistical analyses, including principal component analysis (PCA), soft independent modeling of class analogy (SIMCA), and hierarchical clustering analysis (HCA) were employed. Nineteen samples were analyzed by PCA, SIMCA and HCA. Then the remaining samples (GZM1, SH) were projected onto the SIMCA model to validate the models. The results indicated that, in the use of feature extraction method 2, Danggui from Yunnan Province and Danggui from Gansu Province could be successfully discriminated using the electronic nose coupled with PCA, SIMCA and HCA, which suggested that the electronic-nose system could be used as a simple and rapid technique for the discrimination of Danggui between authentic and unauthentic region of origin.

  16. Method and apparatuses for ion cyclotron spectrometry

    Science.gov (United States)

    Dahl, David A [Idaho Falls, ID; Scott, Jill R [Idaho Falls, ID; McJunkin, Timothy R [Idaho Falls, ID

    2012-03-06

    An ion cyclotron spectrometer may include a vacuum chamber that extends at least along a z-axis and means for producing a magnetic field within the vacuum chamber so that a magnetic field vector is generally parallel to the z-axis. The ion cyclotron spectrometer may also include means for producing a trapping electric field within the vacuum chamber. The trapping electric field may comprise a field potential that, when taken in cross-section along the z-axis, includes at least one section that is concave down and at least one section that is concave up so that ions traversing the field potential experience a net magnetron effect on a cyclotron frequency of the ions that is substantially equal to zero. Other apparatuses and a method for performing ion cyclotron spectrometry are also disclosed herein.

  17. 10 GHz ECRIS for Warsaw Cyclotron

    CERN Document Server

    Sudlitz, K

    1999-01-01

    Cusp type, 10 GHz ECRIS has been built and tested earlier. For obtaining intensive beams, more relevant for cyclotron, cusp geometry has been replaced by hexapole. Discharge chamber (stainless steel, 50 mm diameter, 250 mm long) is an extension of a coaxial line, feeding RF (9,6 GHz, up to 200 W) to the plasma. The NdFeB hexapole (0,52 T on the surface) has been used. The axial magnetic field is created by water cooled coils. The axial injection line dedicated to K160 isochronous heavy ion cyclotron has been constructed. The line consists of Glaser lenses, double focusing magnet, solenoid and mirror type inflector. The system provides sufficient transmission of the beam from ECR ion source to the firsts orbits of the cyclotron for m/q ranging from 7 to 2. After successful initial tests which were done in July 1997 the ECRIS serves as an external source for Warsaw Cyclotron.

  18. Purification of cyclotron-produced {sup 203}Pb for labeling Herceptin

    Energy Technology Data Exchange (ETDEWEB)

    Garmestani, Kayhan [Radioimmune and Inorganic Chemistry Section, Radiation Oncology Branch, NCI, Bethesda, MD 20892-1002 (United States); Milenic, Diane E. [Radioimmune and Inorganic Chemistry Section, Radiation Oncology Branch, NCI, Bethesda, MD 20892-1002 (United States); Brady, Erik D. [Radioimmune and Inorganic Chemistry Section, Radiation Oncology Branch, NCI, Bethesda, MD 20892-1002 (United States); Plascjak, Paul S. [PET Department, Clinical Center, NIH, Bethesda, MD 20892-1002 (United States); Brechbiel, Martin W. [Radioimmune and Inorganic Chemistry Section, Radiation Oncology Branch, NCI, Bethesda, MD 20892-1002 (United States)]. E-mail: martinwb@mail.nih.gov

    2005-04-01

    A simple and rapid procedure was developed for the purification of cyclotron-produced {sup 203}Pb via the {sup 203}Tl(d,2n) {sup 203}Pb reaction. A Pb(II) selective ion-exchange resin, with commercial name Pb Resin from Eichrom Technologies, Inc., was used to purify {sup 203}Pb from the cyclotron-irradiated Tl target with excellent recovery of the enriched Tl target material. The purified {sup 203}Pb was used to radiolabel the monoclonal antibody Herceptin. The in vitro and in vivo properties of the {sup 203}Pb radioimmunoconjugate were evaluated.

  19. Cyclotron Resonance Gain for FIR and THz Radiation in Graphene

    CERN Document Server

    Cole, Nightvid

    2016-01-01

    A cyclotron resonance maser source using low-effective-mass conduction electrons in graphene, if successful, would allow for generation of Far Infrared (FIR) and Terahertz (THz) radiation without requiring magnetic fields running into the tens of Tesla. In order to investigate this possibility, we consider a device in which electrons are effectively injected via pumping from the valence band to the conduction band using an infrared (IR) laser source, subsequently gyrate in a magnetic field applied perpendicular to the plane of the graphene, and give rise to gain for a FIR/THz wave crossing the plane of the graphene. A set of integral expressions is derived by assuming that the non-radiative energy loss processes of the electrons can be adequately represented by a damping force proportional and antiparallel to their momentum. Minimal gain may occur at very short electron damping times of hundreds of femtoseconds.

  20. Rapid discrimination of slimming capsules based on illegal additives by electronic nose and flash gas chromatography.

    Science.gov (United States)

    Xia, Zhenzhen; Cai, Wensheng; Shao, Xueguang

    2015-02-01

    The discrimination of counterfeit and/or illegally manufactured medicines is an important task in the pharmaceutical industry for pharmaceutical safety. In this study, 22 slimming capsule samples with illegally added sibutramine and phenolphthalein were analyzed by electronic nose and flash gas chromatography. To reveal the difference among the different classes of samples, principal component analysis and linear discriminant analysis were employed to analyze the data acquired from electronic nose and flash gas chromatography, respectively. The samples without illegal additives can be discriminated from the ones with illegal additives by using electronic nose or flash gas chromatography data individually. To improve the performance of classification, a data fusion strategy was applied to integrate the data from electronic nose and flash gas chromatography data into a single model. The results show that the samples with phenolphthalein, sibutramine and both can be classified well by using fused data. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Cyclotron axial ion-beam-buncher system

    Energy Technology Data Exchange (ETDEWEB)

    Hamm, R.W.; Swenson, D.A.; Wangler, T.P.

    1982-02-11

    Adiabatic ion bunching is achieved in a cyclotron axial ion injection system through the incorporation of a radio frequency quadrupole system, which receives ions from an external ion source via an accelerate-decelerate system and a focusing einzel lens system, and which adiabatically bunches and then injects the ions into the median plane of a cyclotron via an electrostatic quadrupole system and an inflection mirror.

  2. Building 211 cyclotron characterization survey report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-03-30

    The Building 211 Cyclotron Characterization Survey includes an assessment of the radioactive and chemical inventory of materials stored within the facility; an evaluation of the relative distribution of accelerator-produced activation products within various cyclotron components and adjacent structures; measurement of the radiation fields throughout the facility; measurement and assessment of internal and external radioactive surface contamination on various equipment, facility structures, and air-handling systems; and an assessment of lead (Pb) paint and asbestos hazards within the facility.

  3. Rapid local acceleration of relativistic radiation-belt electrons by magnetospheric chorus.

    Science.gov (United States)

    Thorne, R M; Li, W; Ni, B; Ma, Q; Bortnik, J; Chen, L; Baker, D N; Spence, H E; Reeves, G D; Henderson, M G; Kletzing, C A; Kurth, W S; Hospodarsky, G B; Blake, J B; Fennell, J F; Claudepierre, S G; Kanekal, S G

    2013-12-19

    Recent analysis of satellite data obtained during the 9 October 2012 geomagnetic storm identified the development of peaks in electron phase space density, which are compelling evidence for local electron acceleration in the heart of the outer radiation belt, but are inconsistent with acceleration by inward radial diffusive transport. However, the precise physical mechanism responsible for the acceleration on 9 October was not identified. Previous modelling has indicated that a magnetospheric electromagnetic emission known as chorus could be a potential candidate for local electron acceleration, but a definitive resolution of the importance of chorus for radiation-belt acceleration was not possible because of limitations in the energy range and resolution of previous electron observations and the lack of a dynamic global wave model. Here we report high-resolution electron observations obtained during the 9 October storm and demonstrate, using a two-dimensional simulation performed with a recently developed time-varying data-driven model, that chorus scattering explains the temporal evolution of both the energy and angular distribution of the observed relativistic electron flux increase. Our detailed modelling demonstrates the remarkable efficiency of wave acceleration in the Earth's outer radiation belt, and the results presented have potential application to Jupiter, Saturn and other magnetized astrophysical objects.

  4. Coaxial ring cyclotron as a perspective nuclear power engineering machine

    CERN Document Server

    Tumanyan, A R; Mkrtchyan, R L; Amatuni, T A; Avakian, R O; Khudaverdian, A G

    1995-01-01

    Coaxial Ring Cyclotron (CRC) is described, and its main advantages, such as simple injection technique, several injected beams summation option, high efficiency, are considered. The proposed proton accelerator is a perspective machine for the solution of the main problems of the present day nuclear power engineering as well as for the next-generation nuclear power plants, representing a combination of subcritical reactors and particle accelerators. The possibility of installation of CRCs into ring accelerators with an average diameter from 60 to 100m, e.g., the Yerevan electron synchrotron, is considered.

  5. Peculiar rotation of electron vortex beams.

    Science.gov (United States)

    Schachinger, T; Löffler, S; Stöger-Pollach, M; Schattschneider, P

    2015-11-01

    Standard electron optics predicts Larmor image rotation in the magnetic lens field of a TEM. Introducing the possibility to produce electron vortex beams with quantized orbital angular momentum brought up the question of their rotational dynamics in the presence of a magnetic field. Recently, it has been shown that electron vortex beams can be prepared as free electron Landau states showing peculiar rotational dynamics, including no and cyclotron (double-Larmor) rotation. Additionally very fast Gouy rotation of electron vortex beams has been observed. In this work a model is developed which reveals that the rotational dynamics of electron vortices are a combination of slow Larmor and fast Gouy rotations and that the Landau states naturally occur in the transition region in between the two regimes. This more general picture is confirmed by experimental data showing an extended set of peculiar rotations, including no, cyclotron, Larmor and rapid Gouy rotations all present in one single convergent electron vortex beam. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. On usage of electron observations from Cluster/RAPID/IES instrument in Earth's radiation belts and ring current

    Science.gov (United States)

    Kronberg, Elena; Rashev, Mikhail; Daly, Patrick; Shprits, Yuri; Turner, Drew; Drozdov, Alexander; Dobynde, Mikhail; Kellerman, Adam; Fritz, Ted; Pierrard, Vivien; Borremans, Kris; Klecker, Berndt; Friedel, Reiner

    2017-04-01

    For over 15 years, the Cluster mission passes through Earth's radiation belts at least once every two days for several hours, measuring the energetic electron intensity at energies from 30 to 400 keV. This vast amount of data has previously been considered as rather useless due to contamination by penetrating energetic particles (protons at >100 keV and electrons at >400 keV). In this study, we assess the efficiency with which aluminium shielding of RAPID/IES detector filters out contaminating high-energy electrons and protons. We base our estimation on the analysis of experimental data and a radiation transport code (Geant4). In our simulations, we use the incident particle energy distribution of the AE9/AP9 radiation belt models. We identify the Roederer L-values and energy channels that should be used with caution and show examples of misinterpreting the data, particularly in the slot region. Comparison of the data with electron and proton observations from RBSP/MagEis indicates that the subtraction from the IES electron data of proton intensities at energies 230-630 keV cleans well the data from the proton contamination. We show that the data from this detector measured in the radiation belts is still useful for many scientific applications. This is very valuable as it provides one of the longest available radiation belt data sets.

  7. Rapid progress or lengthy process? electronic personal health records in mental health

    Directory of Open Access Journals (Sweden)

    Denis Mike

    2011-07-01

    Full Text Available Abstract A major objective of many healthcare providers is to increase patients' participation in their own care. The introduction of electronic personal health records (ePHRs may help to achieve this. An ePHR is an electronic database of an individual's health information, accessible to and maintained by the patient. ePHRs are very much in vogue, with an increasing number of studies reporting their potential utility as well as cost. However, the vast majority of these studies focus on general healthcare. Little attempt has been made to document the specific problems which might occur throughout the implementation of ePHRs in mental health. This review identifies such concerns through an electronic search of the literature. Several potential difficulties are highlighted and addressed, including access to information technology, identifying relevant populations and the handling of sensitive information. Special attention is paid to the concept of 'empowerment' and what this means in relation to ePHRs.

  8. The electrostatic ion-cyclotron instability excited by a current to a strip collector

    DEFF Research Database (Denmark)

    Juul Rasmussen, Jens; Schrittwieser, R.; Skøelv, Å.

    1986-01-01

    The electrostatic ion-cyclotron instability is excited in a single-ended Q-machine by drawing an electron current to a strip collector crossing the entire plasma column. The instability is most easily excited when the widths of the strip is a few ion Larmor radii. The instability is confined within...

  9. Stability of electrostatic ion cyclotron waves in a multi-ion plasma

    Indian Academy of Sciences (India)

    A detailed numerical study, for parameters relevant to comet Halley, shows that the growth rate is dependent on the magnitude of the frequency. The ion cyclotron waves are driven by the electron drift parallel to the magnetic field; the temperature anisotropy of the oxygen ions only slightly enhance the growth rates for small ...

  10. Stability of electrostatic ion cyclotron waves in a multi-ion plasma†

    Indian Academy of Sciences (India)

    Abstract. We have studied the stability of the electrostatic ion cyclotron wave in a plasma consisting of isotropic hydrogen ions (H+) and temperature-anisotropic positively. (O+) and negatively (O−) charged oxygen ions, with the electrons drifting parallel to the magnetic field. Analytical expressions have been derived for the ...

  11. Rapid combined light and electron microscopy on large frozen biological samples

    NARCIS (Netherlands)

    Vogels, I. M. C.; Hoeben, K. A.; van Noorden, C. J. F.

    2009-01-01

    P>The use of large unfixed frozen tissue samples (10 x 10 x 5 mm(3)) for combined light microscopy (LM) and electron microscopy (EM) is described. First, cryostat sections are applied for various LM histochemical approaches including in situ hybridization, immunohistochemistry and metabolic mapping

  12. Development of a Fieldable, Rapid, Accurate and Sensitive Bio-Electronic, DNA Biosensor

    Science.gov (United States)

    2004-12-01

    single molecule of DNA or RNA and therefore does not require the use of PCR. The sensor chip can be engineered with an array of hundreds of independent test sites, which allows for confirmatory tests leading to a high level of specificity, the ability to screen for multiple threat agents simultaneously, and the capability to detect genetically engineered organisms. Biological agents continue to pose a major threat to U.S. troops as well as U.S. civilians both domestically and overseas. Rapid, accurate and sensitive detection and identification of biological agents is

  13. Environmentally Benign, Rapid, and Selective Extraction of Gold from Ores and Waste Electronic Materials.

    Science.gov (United States)

    Yue, Chunlin; Sun, Huaming; Liu, Wen-Jing; Guan, Binbin; Deng, Xudong; Zhang, Xu; Yang, Peng

    2017-08-01

    The extraction of gold from ores and electronic waste is an important topic worldwide, as this precious metal has immense value in a variety of fields. However, serious environmental pollution and high energy consumption due to the use of toxic oxidation reagents and harsh reaction conditions is a well-known problem in the gold industry. Herein, we report a new chemical method based on the combined use of N-bromosuccinimide (NBS) and pyridine (Py), which has a greatly decreased environmental impact and reagent cost, as well as mild reaction requirements. This method can directly leach Au0 from gold ore and electronic waste to form AuIII in water. The process is achieved in a yield of approximately 90 % at room temperature and a nearly neutral pH. The minimum dose of NBS/Py is as low as 10 mm, which exhibits low toxicity towards mammalian cells and animals as well as aquatic creatures. The high leaching selectivity of Au over other metals during gold leaching is demonstrated, showing that this method has great potential for practical industrial application towards the sustainable refining of gold from ores and electronic waste. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. A rapid method for combined laser scanning confocal microscopic and electron microscopic visualization of biocytin or neurobiotin-labeled neurons.

    Science.gov (United States)

    Sun, X J; Tolbert, L P; Hildebrand, J G; Meinertzhagen, I A

    1998-02-01

    Intracellular recording and dye filling are widely used to correlate the morphology of a neuron with its physiology. With laser scanning confocal microscopy, the complex shapes of labeled neurons in three dimensions can be reconstructed rapidly, but this requires fluorescent dyes. These dyes are neither permanent nor electron dense and therefore do not allow investigation by electron microscopy. Here we report a technique that quickly and easily converts a fluorescent label into a more stable and electron-dense stain. With this technique, a neuron is filled with Neurobiotin or biocytin, reacted with fluorophore-conjugated avidin, and imaged by confocal microscopy. To permit long-term storage or EM study, the fluorescent label is then converted to a stable electron-dense material by a single-step conversion using a commercially available ABC kit. We find that the method, which apparently relies on recognition of avidin's excess biotin binding sites by the biotin-peroxidase conjugate, is both faster and less labor intensive than photo-oxidation procedures in common use. The technique is readily adaptable to immunocytochemistry with biotinylated probes, as we demonstrate using anti-serotonin as an example.

  15. Residual radioactivity at the Milan AVF cyclotron

    Science.gov (United States)

    Birattari, C.; Cantone, M. C.; Ferrari, A.; Silari, M.

    1989-08-01

    γ-ray spectrometry measurements have been carried out at the Cyclotron Laboratory at the Department of Physics of the University of Milan, to evaluate the levels of residual radioactivity after about one year from shut down. Measurements were performed inside the cyclotron and at several points in the accelerator vault and target room, as well as on specific components removed from the beam transport system, on samples of the concrete shields and on residues taken from the cyclotron vacuum chamber. The radionuclides identified and the values of specific activity and dose rate are reported. The results indicate that no particular hazard and waste disposal problems should be encountered at the time of the decommissioning of the facility.

  16. Improving cancer treatment with cyclotron produced radionuclides

    Energy Technology Data Exchange (ETDEWEB)

    Larson, S.M. Finn, R.D.

    1992-08-04

    This report describes the author's continuing long term goal of promoting nuclear medicine applications by improving the scientific basis for tumor diagnosis treatment and treatment follow-up based on the use of cyclotron produced radiotracers in oncology. The program has 3 interactive components: Radiochemistry /Cyclotron; Pharmacology; and Immunology. An essential strategy is as follows: novel radionuclides and radiotracers developed in the Radiochemistry/Cyclotron section under the DOE grant during the 1989--1992 grant period, will be employed in the Pharmacology and Immunology sections of the DOE grant during the 1992--1995 grant period. The development of novel radionuclides and tracers is of course useful in and of itself, but their utility is greatly enhanced by the interaction with the immunology and pharmacology components of the program.

  17. Rapid imaging of mycoplasma in solution using Atmospheric Scanning Electron Microscopy (ASEM)

    Energy Technology Data Exchange (ETDEWEB)

    Sato, Chikara, E-mail: ti-sato@aist.go.jp [Biomedical Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), 1-1-1 Higashi, Tsukuba, Ibaraki 305-8566 (Japan); Manaka, Sachie [Biomedical Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), 1-1-1 Higashi, Tsukuba, Ibaraki 305-8566 (Japan); Nakane, Daisuke [Department of Biology, Graduate School of Science, Osaka City University, Sumiyoshi-ku, Osaka 558-8585 (Japan); Nishiyama, Hidetoshi; Suga, Mitsuo [Advanced Technology Division, JEOL Ltd., Akishima, Tokyo 196-8558 (Japan); Nishizaka, Takayuki [Department of Physics, Faculty of Science, Gakushuin University, 1-5-1 Mejiro, Toshima-ku, Tokyo 171-8588 (Japan); Miyata, Makoto [Department of Biology, Graduate School of Science, Osaka City University, Sumiyoshi-ku, Osaka 558-8585 (Japan); Maruyama, Yuusuke [Biomedical Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), 1-1-1 Higashi, Tsukuba, Ibaraki 305-8566 (Japan)

    2012-01-27

    Highlights: Black-Right-Pointing-Pointer Mycoplasma mobile was observed in buffer with the Atmospheric Scanning Electron Microscope. Black-Right-Pointing-Pointer Characteristic protein localizations were visualized using immuno-labeling. Black-Right-Pointing-Pointer M. mobile attached to sialic acid on the SiN film surface within minutes. Black-Right-Pointing-Pointer Cells were observed at low concentrations. Black-Right-Pointing-Pointer ASEM should promote study and early-stage diagnosis of mycoplasma. -- Abstract: Mycoplasma is a genus of bacterial pathogen that causes disease in vertebrates. In humans, the species Mycoplasma pneumoniae causes 15% or more of community-acquired pneumonia. Because this bacterium is tiny, corresponding in size to a large virus, diagnosis using optical microscopy is not easy. In current methods, chest X-rays are usually the first action, followed by serology, PCR amplification, and/or culture, but all of these are particularly difficult at an early stage of the disease. Using Mycoplasma mobile as a model species, we directly observed mycoplasma in buffer with the newly developed Atmospheric Scanning Electron Microscope (ASEM). This microscope features an open sample dish with a pressure-resistant thin film window in its base, through which the SEM beam scans samples in solution, from below. Because of its 2-3 {mu}m-deep scanning capability, it can observe the whole internal structure of mycoplasma cells stained with metal solutions. Characteristic protein localizations were visualized using immuno-labeling. Cells were observed at low concentrations, because suspended cells concentrate in the observable zone by attaching to sialic acid on the silicon nitride (SiN) film surface within minutes. These results suggest the applicability of the ASEM for the study of mycoplasmas as well as for early-stage mycoplasma infection diagnosis.

  18. Electronic tongue as a screening tool for rapid analysis of beer.

    Science.gov (United States)

    Polshin, Evgeny; Rudnitskaya, Alisa; Kirsanov, Dmitriy; Legin, Andrey; Saison, Daan; Delvaux, Filip; Delvaux, Freddy R; Nicolaï, Bart M; Lammertyn, Jeroen

    2010-04-15

    An electronic tongue (ET) comprising 18 potentiometric chemical sensors was applied to the quantitative analysis of beer. Fifty Belgian and Dutch beers of different types were measured using the ET. The same samples were analyzed using conventional analytical techniques with respect to the main physicochemical parameters. Only non-correlated physicochemical parameters were retained for further analysis, which were real extract, real fermentation degree, alcohol content, pH, bitterness, color, polyphenol and CO(2) content. Relationship between the ET and physicochemical datasets was studied using Canonical Correlation Analysis (CCA). Four significant canonical variates were extracted using CCA. Correlation was observed between 6 physicochemical variables (real extract and fermentation degree, bitterness, pH, alcohol and polyphenols' content) and 14 sensors of the ET. The feasibility of the ET for the quantification of bitterness in beer was evaluated in the aqueous solutions of isomerized hop extract and in the set of 11 beers with bitterness varying between 14 and 38 EBU (European Bitterness Units). Sensors displayed good sensitivity to isomerized hop extract and good prediction of the bitterness in beer was obtained. Calibration models with respect to the physicochemical parameters using ET measurements in 50 Belgian and Dutch beer samples were calculated by Partial Least Square regression. The ET was capable of predicting such parameters as real extract, alcohol and polyphenol content and bitterness, the latter with Root Mean Square Error of Prediction (RMSEP) of 2.5. (c) 2009 Elsevier B.V. All rights reserved.

  19. Dispersion equations for field-aligned cyclotron waves in axisymmetric magnetospheric plasmas

    Directory of Open Access Journals (Sweden)

    N. I. Grishanov

    2006-03-01

    Full Text Available In this paper, we derive the dispersion equations for field-aligned cyclotron waves in two-dimensional (2-D magnetospheric plasmas with anisotropic temperature. Two magnetic field configurations are considered with dipole and circular magnetic field lines. The main contribution of the trapped particles to the transverse dielectric permittivity is estimated by solving the linearized Vlasov equation for their perturbed distribution functions, accounting for the cyclotron and bounce resonances, neglecting the drift effects, and assuming the weak connection of the left-hand and right-hand polarized waves. Both the bi-Maxwellian and bi-Lorentzian distribution functions are considered to model the ring current ions and electrons in the dipole magnetosphere. A numerical code has been developed to analyze the dispersion characteristics of electromagnetic ion-cyclotron waves in an electron-proton magnetospheric plasma with circular magnetic field lines, assuming that the steady-state distribution function of the energetic protons is bi-Maxwellian. As in the uniform magnetic field case, the growth rate of the proton-cyclotron instability (PCI in the 2-D magnetospheric plasmas is defined by the contribution of the energetic ions/protons to the imaginary part of the transverse permittivity elements. We demonstrate that the PCI growth rate in the 2-D axisymmetric plasmasphere can be significantly smaller than that for the straight magnetic field case with the same macroscopic bulk parameters.

  20. Rapid Classification of Hairtail Fish and Pork Freshness Using an Electronic Nose Based on the PCA Method

    Directory of Open Access Journals (Sweden)

    Yong-Ming Zhang

    2011-12-01

    Full Text Available We report a method for building a simple and reproducible electronic nose based on commercially available metal oxide sensors (MOS to monitor the freshness of hairtail fish and pork stored at 15, 10, and 5 °C. After assembly in the laboratory, the proposed product was tested by a manufacturer. Sample delivery was based on the dynamic headspace method, and two features were extracted from the transient response of each sensor using an unsupervised principal component analysis (PCA method. The compensation method and pattern recognition based on PCA are discussed in the current paper. PCA compensation can be used for all storage temperatures, however, pattern recognition differs according to storage conditions. Total volatile basic nitrogen (TVBN and aerobic bacterial counts of the samples were measured simultaneously with the standard indicators of hairtail fish and pork freshness. The PCA models based on TVBN and aerobic bacterial counts were used to classify hairtail fish samples as “fresh” (TVBN ≤ 25 g and microbial counts ≤ 106 cfu/g or “spoiled” (TVBN ≥ 25 g and microbial counts ≥ 106 cfu/g and pork samples also as “fresh” (TVBN ≤ 15 g and microbial counts ≤ 106 cfu/g or “spoiled” (TVBN ≥ 15 g and microbial counts ≥ 106 cfu/g. Good correlation coefficients between the responses of the electronic nose and the TVBN and aerobic bacterial counts of the samples were obtained. For hairtail fish, correlation coefficients were 0.97 and 0.91, and for pork, correlation coefficients were 0.81 and 0.88, respectively. Through laboratory simulation and field application, we were able to determine that the electronic nose could help ensure the shelf life of hairtail fish and pork, especially when an instrument is needed to take measurements rapidly. The results also showed that the electronic nose could analyze the process and level of spoilage for hairtail fish and pork.

  1. Rapid application design of an electronic clinical skills portfolio for undergraduate medical students.

    Science.gov (United States)

    Dornan, Tim; Lee, Catherine; Stopford, Adam; Hosie, Liam; Maredia, Neil; Rector, Alan

    2005-04-01

    The aim was to find how to use information and communication technology to present the clinical skills content of an undergraduate medical curriculum. Rapid application design was used to develop the product, and technical action research was used to evaluate the development process. A clinician-educator, two medical students, two computing science masters students, two other project workers, and a hospital education informatics lead, formed a design team. A sample of stakeholders took part in requirements planning workshops and continued to advise the team throughout the project. A university hospital had many features that favoured fast, inexpensive, and successful system development: a clearly defined and readily accessible user group; location of the development process close to end-users; fast, informal communication; leadership by highly motivated and senior end-users; devolved authority and lack of any rigidly imposed management structure; cooperation of clinicians because the project drew on their clinical expertise to achieve scholastic goals; a culture of learning and involvement of highly motivated students. A detailed specification was developed through storyboarding, use case diagramming, and evolutionary prototyping. A very usable working product was developed within weeks. "SkillsBase" is a database web application using Microsoft Active Server Pages, served from a Microsoft Windows 2000 Server operating system running Internet Information Server 5.0. Graphing functionality is provided by the KavaChart applet. It presents the skills curriculum, provides a password-protected portfolio function, and offers training materials. The curriculum can be presented in several different ways to help students reflect on their objectives and progress towards achieving them. The reflective portfolio function is entirely private to each student user and allows them to document their progress in attaining skills, as judged by self, peer and tutor assessment, and

  2. Rapid direct analysis to discriminate geographic origin of extra virgin olive oils by flash gas chromatography electronic nose and chemometrics.

    Science.gov (United States)

    Melucci, Dora; Bendini, Alessandra; Tesini, Federica; Barbieri, Sara; Zappi, Alessandro; Vichi, Stefania; Conte, Lanfranco; Gallina Toschi, Tullia

    2016-08-01

    At present, the geographical origin of extra virgin olive oils can be ensured by documented traceability, although chemical analysis may add information that is useful for possible confirmation. This preliminary study investigated the effectiveness of flash gas chromatography electronic nose and multivariate data analysis to perform rapid screening of commercial extra virgin olive oils characterized by a different geographical origin declared in the label. A comparison with solid phase micro extraction coupled to gas chromatography mass spectrometry was also performed. The new method is suitable to verify the geographic origin of extra virgin olive oils based on principal components analysis and discriminant analysis applied to the volatile profile of the headspace as a fingerprint. The selected variables were suitable in discriminating between "100% Italian" and "non-100% Italian" oils. Partial least squares discriminant analysis also allowed prediction of the degree of membership of unknown samples to the classes examined. Copyright © 2016. Published by Elsevier Ltd.

  3. The Data Cyclotron query processing scheme

    NARCIS (Netherlands)

    Goncalves, R.; Kersten, M.

    2011-01-01

    A grand challenge of distributed query processing is to devise a self-organizing architecture which exploits all hardware resources optimally to manage the database hot set, minimize query response time, and maximize throughput without single point global coordination. The Data Cyclotron

  4. The Data Cyclotron query processing scheme.

    NARCIS (Netherlands)

    R.A. Goncalves (Romulo); M.L. Kersten (Martin)

    2011-01-01

    htmlabstractA grand challenge of distributed query processing is to devise a self-organizing architecture which exploits all hardware resources optimally to manage the database hot set, minimize query response time, and maximize throughput without single point global coordination. The Data Cyclotron

  5. <600> MeV synchro-cyclotron

    CERN Multimedia

    CERN PhotoLab

    1971-01-01

    One of the 14 pancakes of the new magnet coils for the 600 MeV synchro-cyclotron which were wound and coated with epoxy resin on the CERN site. These new coils will replace the present ones which have been in use for more than 14 years but are now showing signs of deteriorations.

  6. Development of the cyclotron radioisotope production technology

    Energy Technology Data Exchange (ETDEWEB)

    Suh, Yong Sup; Chun, K.S.; Yang, S.D.; Lee, J.D.; Ahn, S.H.; Yun, Y.K.; Park, H.; Lee, J.S.; Chai, J.S.; Kim, U.S.; Hong, S.S.; Lee, M.Y.; Park, C.W.; Baik, S. K.; Kim, E. H.; Kim, T. K.; Kim, K. S.; Kim, J. H

    1999-04-01

    The purpose of this study is to contribute the advance of nuclear medicine and to the improvement of human health through the development of various accelerator radionuclides and mass production with automization of production. The results obtained from this study are following: 1) In order to introduce 30 MeV high current cyclotron, the specification of cyclotron has been made, the building site was selected and we drew the draw-up of cyclotron. The cyclotron installation contract was postponed until the financial resources could be secured. 2) For a development high purity 1-123 producing system, a Xe-124 target system, a temperature measurement system of the inner part of the target and a target window were fabricated. A Xe-124 gas target recovery system and a full production system of 1-123 was drew up. 3) For a development of a therapeutic nuclide At-211, a target for the production of At-211 via {sup 209}Bi(alpha, 2n) reaction was fabricated. Produced At-211 was separated by distillation method. 4) For development of beta-emitting nuclides, Ti-45, C-11, F{sub 2}-18, beam irradiation system suitable for each target were fabricated. 5) For automatic production of Ga-67, automated module and PLC program was made 6) For the quality control of radiopharmaceuticals, analytical method of thallium and copper by polarography was investigated and established.

  7. Resonant cyclotron scattering in magnetars' emission

    NARCIS (Netherlands)

    Rea, N.; Zane, S.; Turolla, R.; Lyutikov, M.; Götz, D.

    2008-01-01

    We present a systematic fit of a model of resonant cyclotron scattering (RCS) to the X-ray data of 10 magnetars, including canonical and transient anomalous X-ray pulsars (AXPs) and soft gamma repeaters (SGRs). In this scenario, nonthermal magnetar spectra in the soft X-rays (i.e., below ~10 keV)

  8. Program Complex For Cyclotron Beam Dynamic Simulations

    CERN Document Server

    Glazov, A A; Karamysheva, G A; Lisenkova, O E

    2004-01-01

    The program complex in MATLAB intended for particle dynamic simulations is described. Programming in an easy-to-use environment permits creation of models in a short space of time. Advanced graphical tools of MATLAB give good visualization features to created models. The beam dynamic modelling results by the example of two different cyclotron designs are presented.

  9. SC Cyclotron and RIB Facilities in Kolkata

    CERN Document Server

    Sinha, Bikash; Chakrabarti, Alok

    2005-01-01

    The superconducting cyclotron under construction at this Centre has bending limit (K-bend) of 520 and focusing limit (K-foc) of 160. It is being constructed, primarily, for nuclear physics experiments with heavy ion beams at intermediate energies. The 100-ton main magnet is currently in the commissioning phase with the main coil already at 4.2K temperature. Magnetic field measurements will be carried out over the next several months. All other systems of the cyclotron are in an advanced stage of fabrication or development. We plan to start assembly of the complete cyclotron around the end of 2005. In the phase-I of the project one beam line has been provided. Construction of three more beam lines and various experimental facilities for nuclear physics as well as irradiation experiments has also been funded and the work is well on its way. An ISOL type Radioactive Ion Beam (RIB) facility is being built with the existing K=130 room temperature cyclotron, VEC, as the primary beam source. In-beam RIB production a...

  10. Cyclotron-based neutron source for BNCT

    Science.gov (United States)

    Mitsumoto, T.; Yajima, S.; Tsutsui, H.; Ogasawara, T.; Fujita, K.; Tanaka, H.; Sakurai, Y.; Maruhashi, A.

    2013-04-01

    Kyoto University Research Reactor Institute (KURRI) and Sumitomo Heavy Industries, Ltd. (SHI) have developed a cyclotron-based neutron source for Boron Neutron Capture Therapy (BNCT). It was installed at KURRI in Osaka prefecture. The neutron source consists of a proton cyclotron named HM-30, a beam transport system and an irradiation & treatment system. In the cyclotron, H- ions are accelerated and extracted as 30 MeV proton beams of 1 mA. The proton beams is transported to the neutron production target made by a beryllium plate. Emitted neutrons are moderated by lead, iron, aluminum and calcium fluoride. The aperture diameter of neutron collimator is in the range from 100 mm to 250 mm. The peak neutron flux in the water phantom is 1.8×109 neutrons/cm2/sec at 20 mm from the surface at 1 mA proton beam. The neutron source have been stably operated for 3 years with 30 kW proton beam. Various pre-clinical tests including animal tests have been done by using the cyclotron-based neutron source with 10B-p-Borono-phenylalanine. Clinical trials of malignant brain tumors will be started in this year.

  11. Cyclotron-based neutron source for BNCT

    Energy Technology Data Exchange (ETDEWEB)

    Mitsumoto, T.; Yajima, S.; Tsutsui, H.; Ogasawara, T.; Fujita, K. [Sumitomo Heavy Industries, Ltd (Japan); Tanaka, H.; Sakurai, Y.; Maruhashi, A. [Kyoto University Research Reactor Institute (Japan)

    2013-04-19

    Kyoto University Research Reactor Institute (KURRI) and Sumitomo Heavy Industries, Ltd. (SHI) have developed a cyclotron-based neutron source for Boron Neutron Capture Therapy (BNCT). It was installed at KURRI in Osaka prefecture. The neutron source consists of a proton cyclotron named HM-30, a beam transport system and an irradiation and treatment system. In the cyclotron, H- ions are accelerated and extracted as 30 MeV proton beams of 1 mA. The proton beams is transported to the neutron production target made by a beryllium plate. Emitted neutrons are moderated by lead, iron, aluminum and calcium fluoride. The aperture diameter of neutron collimator is in the range from 100 mm to 250 mm. The peak neutron flux in the water phantom is 1.8 Multiplication-Sign 109 neutrons/cm{sup 2}/sec at 20 mm from the surface at 1 mA proton beam. The neutron source have been stably operated for 3 years with 30 kW proton beam. Various pre-clinical tests including animal tests have been done by using the cyclotron-based neutron source with {sup 10}B-p-Borono-phenylalanine. Clinical trials of malignant brain tumors will be started in this year.

  12. Analytical study of effects of positron density and temperature anisotropy on electrostatic ion cyclotron instability

    Science.gov (United States)

    Barati Moqadam Niyat, M.; Khorashadizadeh, S. M.; Niknam, A. R.

    2017-03-01

    The effects of the positron concentration and ion temperature anisotropy on the electrostatic ion cyclotron instability are studied analytically, in a magnetized electron-positron-ion plasma with temperature anisotropy, using the linear kinetic theory. Positrons and electrons are supposed to drift either in the same direction or in opposite directions relative to singly ionized stationary ions and parallel to the magnetic field. The dispersion relation of the electrostatic ion cyclotron waves is derived, and then the conditions for exciting the instability of the waves are investigated. Moreover, the condition for the marginally stable state is also studied. It is found that as the positron concentration and perpendicular ion temperature increase, the growth rate of the electrostatic ion cyclotron instability decreases, whereas the critical drift velocity increases. It is also found that for the chosen set of parameters, with electrons and positrons drifting in the same direction, the instability in the plasma is stronger than when the electrons and positrons drift in opposite directions. In addition, a comparison is made to the normal electron-ion plasma.

  13. EBCO Technologies TR Cyclotrons, Dynamics, Equipment, and Applications

    Science.gov (United States)

    Johnson, R. R.; Erdman, K. L.; Gyles, Wm.; Burbee, J.; VanLier, E.; Kovacs, M.; Perron, F.

    2003-08-01

    The Ebco Technologies TR cyclotrons have a common parent in the 500 MeV negative ion cyclotron at TRIUMF in Vancouver. As such, the TR cyclotrons have features that can be adapted for specific application. The cyclotron design is modularized into ion source and injection system, central region and then extraction. The cyclotron ion source is configured for cyclotron beam currents ranging from 50 microAmps to 2 milliAmps. The injection line can be operated in either continuous (CW) or in pulsed mode. The center region of the cyclotron is configured to match the ion source configuration. The extracted beams are directed either to a local target station or to beam lines and thence to target stations. There has been development both in solid, liquid and gas targets. There has been development in radioisotope handling techniques, target material recovery and radiochemical synthesis.

  14. Experimental observation of acoustic emissions generated by a pulsed proton beam from a hospital-based clinical cyclotron.

    Science.gov (United States)

    Jones, Kevin C; Vander Stappen, François; Bawiec, Christopher R; Janssens, Guillaume; Lewin, Peter A; Prieels, Damien; Solberg, Timothy D; Sehgal, Chandra M; Avery, Stephen

    2015-12-01

    To measure the acoustic signal generated by a pulsed proton spill from a hospital-based clinical cyclotron. An electronic function generator modulated the IBA C230 isochronous cyclotron to create a pulsed proton beam. The acoustic emissions generated by the proton beam were measured in water using a hydrophone. The acoustic measurements were repeated with increasing proton current and increasing distance between detector and beam. The cyclotron generated proton spills with rise times of 18 μs and a maximum measured instantaneous proton current of 790 nA. Acoustic emissions generated by the proton energy deposition were measured to be on the order of mPa. The origin of the acoustic wave was identified as the proton beam based on the correlation between acoustic emission arrival time and distance between the hydrophone and proton beam. The acoustic frequency spectrum peaked at 10 kHz, and the acoustic pressure amplitude increased monotonically with increasing proton current. The authors report the first observation of acoustic emissions generated by a proton beam from a hospital-based clinical cyclotron. When modulated by an electronic function generator, the cyclotron is capable of creating proton spills with fast rise times (18 μs) and high instantaneous currents (790 nA). Measurements of the proton-generated acoustic emissions in a clinical setting may provide a method for in vivo proton range verification and patient monitoring.

  15. Studies of suprathermal emission due to cyclotron-electronic heating of the tokamak TCV plasma; Etudes du rayonnement suprathermique emis lors du chauffage cyclotronique electronique du plasma du tokamak TCV

    Energy Technology Data Exchange (ETDEWEB)

    Blanchard, P

    2002-07-01

    Photo sensitization of wide band gap semiconductors is used in a wide range of application like silver halide photography and xerography. The development of a new type of solar cells, based on the sensitization of meso porous metal oxide films by panchromatic dyes, has triggered a lot of fundamental research on electron transfer dynamics. Upon excitation, the sensitizer transfers an electron in the conduction band of the semiconductor. Recombination of the charge separated state is prevented by the fast regeneration of the dye by an electron donor present in solution. Until recently, most of the work in this area has been focused on the competition between the recombination and the regeneration processes, which take place in the nanosecond to millisecond regime. With the development of solid-state femtosecond laser, the measurement of the dynamics of the first electron transfer step occurring in the solar cell has become possible . Electron injection from ruthenium(Il) poly pyridyl complexes into titanium dioxide has been found to occur with a poly exponential rate, with time constants ranging from < 100 fs up to > 10 ps. In spite of the lately acquired capacity to measure the dynamics of these reactions, the physical meaning of this poly exponential kinetics and the factors that can influence this process are still poorly understood. In this work, the development of a new femtosecond pump-probe spectrometer, intended to monitor the ultrafast dynamics of electron injection, is presented. The study of this process requires an excellent temporal resolution and a large wavelength tunability to be able to excite a great variety of dyes and to probe the different products of the reaction. These specifications were met using the latest progress made in optical parametric amplification, which allowed the construction of a versatile experimental set-up. The interfacing by computer of the different devices used during the experiments increase the ease of use of the set

  16. Electromagnetic ion/ion cyclotron instability - Theory and simulations

    Science.gov (United States)

    Winske, D.; Omidi, N.

    1992-01-01

    Linear theory and 1D and 2D hybrid simulations are employed to study electromagnetic ion/ion cyclotron (EMIIC) instability driven by the relative streaming of two field-aligned ion beams. The characteristics of the instability are studied as a function of beam density, propagation angle, electron-ion temperature ratios, and ion beta. When the propagation angle is near 90 deg the EMIIC instability has the characteristics of an electrostatic instability, while at smaller angles electromagnetic effects play a significant role as does strong beam coupling. The 2D simulations point to a narrowing of the wave spectrum and accompanying coherent effects during the linear growth stage of development. The EMIIC instability is an important effect where ion beta is low such as in the plasma-sheet boundary layer and upstream of slow shocks in the magnetotail.

  17. Data processing in Fourier transform ion cyclotron resonance mass spectrometry.

    Science.gov (United States)

    Qi, Yulin; O'Connor, Peter B

    2014-01-01

    The Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometer intricately couples advanced physics, instrumentation, and electronics with chemical and particularly biochemical research. However, general understanding of the data processing methodologies used lags instrumentation, and most data processing algorithms we are familiar with in FT-ICR are not well studied; thus, professional skill and training in FT-ICR operation and data analysis is still the key to achieve high performance in FT-ICR. This review article is focused on FT-ICR data processing, and explains the procedures step-by-step for users with the goal of maximizing spectral features, such as mass accuracy, resolving power, dynamic range, and detection limits. © 2014 Wiley Periodicals, Inc.

  18. Van Allen Probes observations of oxygen cyclotron harmonic waves in the inner magnetosphere

    Science.gov (United States)

    Usanova, M.; Malaspina, D.; Jaynes, A. N.; Bruder, R.; Mann, I. R.; Wygant, J. R.; Ergun, R.

    2016-12-01

    Waves with frequencies in the vicinity of the oxygen cyclotron frequency and its harmonics have been regularly observed on the Van Allen Probes satellites during geomagnetic storms. We focus on properties of these waves and present events from the main phase of two storms on November 1, 2012 and March 17, 2013 and associated dropouts of few MeV electron fluxes. They are electromagnetic, in the frequency range 0.5 - several Hz, and amplitude 0.1- a few nT in magnetic and 0.1- a few mV/m in electric field, with both the wave velocity and the Poynting vector directed almost parallel to the background magnetic field. These properties are very similar to those of electromagnetic ion cyclotron (EMIC) waves, which are believed to contribute to loss of ring current ions and radiation belt electrons and therefore can be also important for inner magnetosphere dynamics.

  19. Structure and Dissipation Characteristics of an Electron Diffusion Region Observed by MMS During a Rapid, Normal-Incidence Magnetopause Crossing

    Science.gov (United States)

    Torbert, R. B.; Burch, J. L.; Argall, M. R.; Alm, L.; Farrugia, C. J.; Forbes, T. G.; Giles, B. L.; Rager, A.; Dorelli, J.; Strangeway, R. J.; Ergun, R. E.; Wilder, F. D.; Ahmadi, N.; Lindqvist, P.-A.; Khotyaintsev, Y.

    2017-12-01

    On 22 October 2016, the Magnetospheric Multiscale (MMS) spacecraft encountered the electron diffusion region (EDR) when the magnetosheath field was southward, and there were signatures of fast reconnection, including flow jets, Hall fields, and large power dissipation. One rapid, normal-incidence crossing, during which the EDR structure was almost stationary in the boundary frame, provided an opportunity to observe the spatial structure for the zero guide field case of magnetic reconnection. The reconnection electric field was determined unambiguously to be 2-3 mV/m. There were clear signals of fluctuating parallel electric fields, up to 6 mV/m on the magnetosphere side of the diffusion region, associated with a Hall-like parallel current feature on the electron scale. The width of the main EDR structure was determined to be 2 km (1.8 de). Although the MMS spacecraft were in their closest tetrahedral separation of 8 km, the divergences and curls for these thin current structures could therefore not be computed in the usual manner. A method is developed to determine these quantities on a much smaller scale and applied to compute the normal component of terms in the generalized Ohm's law for the positions of each individual spacecraft (not a barocentric average). Although the gradient pressure term has a qualitative dependence that follows the observed variation of E + Ve × B, the quantitative magnitude of these terms differs by more than a factor of 2, which is shown to be greater than the respective errors. Thus, future research is required to find the manner in which Ohm's law is balanced.

  20. ECR ion source with electron gun

    Science.gov (United States)

    Xie, Z.Q.; Lyneis, C.M.

    1993-10-26

    An Advanced Electron Cyclotron Resonance ion source having an electron gun for introducing electrons into the plasma chamber of the ion source is described. The ion source has a injection enclosure and a plasma chamber tank. The plasma chamber is defined by a plurality of longitudinal magnets. The electron gun injects electrons axially into the plasma chamber such that ionization within the plasma chamber occurs in the presence of the additional electrons produced by the electron gun. The electron gun has a cathode for emitting electrons therefrom which is heated by current supplied from an AC power supply while bias potential is provided by a bias power supply. A concentric inner conductor and outer conductor carry heating current to a carbon chuck and carbon pusher which hold the cathode in place and also heat the cathode. In the Advanced Electron Cyclotron Resonance ion source, the electron gun replaces the conventional first stage used in prior electron cyclotron resonance ion generators. 5 figures.

  1. Fourier Transform Ion Cyclotron Resonance Mass Spectrometry at the Cyclotron Frequency.

    Science.gov (United States)

    Nagornov, Konstantin O; Kozhinov, Anton N; Tsybin, Yury O

    2017-04-01

    The phenomenon of ion cyclotron resonance allows for determining mass-to-charge ratio, m/z, of an ensemble of ions by means of measurements of their cyclotron frequency, ω c . In Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS), the ω c quantity is usually unavailable for direct measurements: the resonant state is located close to the reduced cyclotron frequency (ω+), whereas the ω c and the corresponding m/z values may be calculated via theoretical derivation from an experimental estimate of the ω+ quantity. Here, we describe an experimental observation of a new resonant state, which is located close to the ω c frequency and is established because of azimuthally-dependent trapping electric fields of the recently developed ICR cells with narrow aperture detection electrodes. We show that in mass spectra, peaks close to ω+ frequencies can be reduced to negligible levels relative to peaks close to ω c frequencies. Due to reduced errors with which the ω c quantity is obtained, the new resonance provides a means of cyclotron frequency measurements with precision greater than that achieved when ω+ frequency peaks are employed. The described phenomenon may be considered for a development into an FT-ICR MS technology with increased mass accuracy for applications in basic research, life, and environmental sciences. Graphical Abstract ᅟ.

  2. Effects of rapid thermal annealing on two-dimensional delocalized electronic states of the epitaxial N δ-doped layer in GaAs

    Energy Technology Data Exchange (ETDEWEB)

    Ogawa, Yasuhiro; Harada, Yukihiro; Baba, Takeshi; Kaizu, Toshiyuki; Kita, Takashi [Department of Electrical and Electronic Engineering, Graduate School of Engineering, Kobe University, 1-1 Rokkodai, Nada, Kobe 657-8501 (Japan)

    2016-03-14

    We have conducted rapid thermal annealing (RTA) for improving the two-dimensional (2D) arrangement of electronic states in the epitaxial nitrogen (N) δ-doped layer in GaAs. RTA rearranged the N-pair configurations in the GaAs (001) plane and reduced the number of non-radiative recombination centers. Furthermore, a Landau shift, representing the 2D delocalized electronic states in the (001) plane, was observed at around zero magnetic field intensity in the Faraday configuration.

  3. Rapid and Accurate Identification of Adulterants via an Electronic Nose and DNA Identification Platform: Identification of Fake Velvet Antlers as an Example

    OpenAIRE

    Guojie Xu; Chunsheng Liu; Caili Liao; Xiaolei Ren; Xinyue Zhang; Xiaorui Fu; Xueyong Wang

    2016-01-01

    Background. Adulterants in Chinese medicines had always affected the efficacy of Chinese medicines and resulted in safety problems in drug use. We aimed to take the identification of fake velvet antlers as an example for establishment of a rapid and accurate identification platform for modern pharmaceutical companies and markets of Chinese medicine. Methods. In this study, we developed a novel electronic nose and DNA identification platform for identifying fake velvet antlers. Electronic nose...

  4. Spin-orbit splitting of the cyclotron resonance in GaAs

    Science.gov (United States)

    Tonello, P.; Lipparini, E.

    2004-08-01

    We have studied the relevance of spin-orbit coupling to the splitting of the cyclotron resonance of electron space-charge layers in GaAs recently observed by Manger [Phys. Rev. B 63, 121203R (2001)]. We show that the spin-orbit interaction couples density and spin-density excitations in the long-wavelength limit and is able to explain all the features observed in the experiment.

  5. A Novel Laser Direct Writing System Integrated with A&F XXY Alignment Platform for Rapid Fabrication of Flexible Electronics

    Directory of Open Access Journals (Sweden)

    Yi-Kai Liu

    2015-05-01

    Full Text Available In this study, a novel laser direct synthesis and pattering technology is applied in conjunction with an A&F XXY alignment platform to rapidly fabricate flexible conductors on a polymer substrate (polyimide film with designated patterns. In the process, a focused continuous wave green laser was focused onto the polymer substrate that is mounted and directed using the XXY alignment platform. The focused laser energy absorbed by the polymer substrate is used to heat the transparent and particle-free reactive silver ink on the polymer substrate surface. With appropriate programing of the XXY alignment platform motion to control the laser scanning parameters, silver patterns with good electrical conductivity were successfully obtained. This technology can be operated directly at atmospheric pressure and room temperature. It does not require the use of vacuum chamber, oven and photo-mask, etc. Therefore, this novel technology and system offers a new approach to the cost-effective and green fabrication for flexible electronics. The compact size and excellent stability of the XXY alignment platform make the fabrication system even more competitive. In particular, the programmable small radius plane rotation function of the XXY alignment platform provides flexibility in the pattern design with turnings while keeps the uniformity of the resulted micro metal lines.

  6. Rapid genotyping of common MeCP2 mutations with an electronic DNA microchip using serial differential hybridization.

    Science.gov (United States)

    Thistlethwaite, William A; Moses, Linda M; Hoffbuhr, Kristen C; Devaney, Joseph M; Hoffman, Eric P

    2003-05-01

    Rett syndrome is a neurodevelopmental disorder that affects females almost exclusively, and in which eight common point mutations on the X-linked MeCP2 gene are knows to cause over 70% of mutation-positive cases. We explored the use of a novel platform to detect the eight common mutations in Rett syndrome patients to expedite and simplify the process of identification of known genotypes. The Nanogen workstation consists of a two-color assay based on electric hybridization and thermal discrimination, all performed on an electronically active NanoChip. This genotyping platform was tested on 362 samples of a pre-determined genotype, which had been previously identified by a combination of DHPLC (denaturing high performance liquid chromatography) and direct sequencing. This genotyping technique proved to be rapid, facile, and displayed a specificity of 100% with 3% ambiguity. In addition, we present consecutive testing of seven mutations on a single pad of the NanoChip. This was accomplished by tagging down two amplimers together and serially hybridizing for seven different loci, allowing us to genotype samples for seven of the eight common Rett mutations on a single pad. This novel method displayed the same level of specificity and accuracy as the single amplimer reactions, and proved to be faster and more economical.

  7. Beam stripping extraction from the VINCY cyclotron

    Directory of Open Access Journals (Sweden)

    Ristić-Đurović Jasna L.

    2006-01-01

    Full Text Available The extraction system of a cyclotron guides an ion beam from a spiral acceleration orbit, through an extraction trajectory, into a high energy transport line. The two methods commonly used to direct an ion into the extraction path are deflection, by the electric field of an electrostatic deflector, and ion stripping, by a thin carbon foil. Compared to the electrostatic deflector system, the stripping extraction provides a fast and easy change of the extracted ion energy and is easier to manufacture operate, and maintain. However, the extraction trajectory and dynamics of an ion beam after stripping are highly dependant on the ion energy and specific charge. Thus, when a multipurpose machine such as the VINCY Cyclotron is concerned, it is far from easy to deliver a variety of ion beams into the same high energy transport line and at the same time preserve a reasonable compactness of the extraction system. The front side stripping extraction system of the VINCY Cyclotron provides high (~70 MeV and mid (~30 MeV energy protons, as well as a number of heavy ions in broad energy ranges. The back side stripping extraction system extracts low energy protons (~18 MeV and enables their simultaneous use with high energy protons at the front side of the machine.

  8. Effect of finite ωτ on cyclotron-wave propagation in metals in the long-wavelength limit

    DEFF Research Database (Denmark)

    Frandsen, J. B.; Gordon, R A

    1976-01-01

    Exact calculations of cyclotron-wave dispersion curves have been carried out for a degenerate free-electron metal including finite relaxation time effects. The calculated dispersion curves are shown to differ substantially from the experimental dispersion curves in the long-wavelength limit...

  9. Metal impurity transport control in JET H-mode plasmas with central ion cyclotron radiofrequency power injection

    DEFF Research Database (Denmark)

    Valisa, M.; Carraro, L.; Predebon, I.

    2011-01-01

    The scan of ion cyclotron resonant heating (ICRH) power has been used to systematically study the pump out effect of central electron heating on impurities such as Ni and Mo in H-mode low collisionality discharges in JET. The transport parameters of Ni and Mo have been measured by introducing a t...

  10. Plug-and-play paper-based toolkit for rapid prototyping of microfluidics and electronics towards point-of-care diagnostic solutions

    CSIR Research Space (South Africa)

    Smith, S

    2015-11-01

    Full Text Available -1 RAPDASA 2015 conference, Roodevallei, Pretoria, 4 - 6 November 2015 PLUG-AND-PLAY PAPER-BASED TOOLKIT FOR RAPID PROTOTYPING OF MICROFLUIDICS AND ELECTRONICS TOWARDS POINT-OF-CARE DIAGNOSTIC SOLUTIONS S. Smith1*, K. Moodley2 & K. Land3 1...

  11. High dilution surface-enhanced Raman spectroscopy for rapid determination of nicotine in e-liquids for electronic cigarettes.

    Science.gov (United States)

    Itoh, Nobuyasu; Bell, Steven E J

    2017-03-13

    The rise in popularity of electronic cigarettes and the associated new legislation concerning e-liquids has created a requirement for a rapid method for determining the nicotine content of e-liquids in the field, ideally at the point of sale. Here we have developed a rapid method based on surface-enhanced Raman spectroscopy (SERS) with Au colloids and an isotope-labeled nicotine (d4-nicotine) internal standard for the measurement/quantification of samples which contain 10s of mg mL-1 nicotine in a complex viscous matrix. This method is novel within the area of SERS because it uses high dilution (ca. 4000×) in the sample preparation which dilutes out the effects of the viscous glycerin/glycerol medium and any flavouring or colouring agents present but still allows for very accurate calibration with high reproducibility. This is possible because the nicotine concentration in the e-liquids (≤24 mg mL-1) is of several orders of magnitude above the working range of the SERS measurement. This method has been tested using a portable Raman spectrometer and a very large set of 42 commercial e-liquids to check that there is no matrix interference associated with different manufacturers/flavourings/colouring agents etc. Finally, as an alternative to determining the nicotine concentration by measuring peak heights in the spectra, the concentration was also estimated by comparing the sample spectra with those of a set of standard samples which were prepared at known concentrations and held in a spectral library file in the spectrometer. This simple approach allows the concentration to be estimated without any complex data analysis and lends itself readily to a handheld Raman system which is typically designed to carry out library searching using the internal software for materials identification. Library searching against standards correctly classified 41 of the 42 test liquids as belonging to the correct concentration group. This high dilution SERS approach is suitable for

  12. Numerical Simulation Of The Beam Transmission Efficiency For Design Of Vacuum System Of The Dc-72 Cyclotron

    CERN Document Server

    Tikhomirov, A V; Gulbekyan, G G; Oganesyan, R T

    2004-01-01

    The results of a numerical modelling of the transmission efficiency of ion beams in conditions of ion recharge on the residual gas in the channel of the axial injection, in the cyclotron vacuum chamber, as well as in transport lines of accelerated beams are presented. The computer simulation programs GENAP and VACLOS have been developed and tested on the basis of experiments on four cyclotrons of heavy ions of the Flerov Laboratory of Nuclear Reactions. They estimate beam losses on the basis of calculations of pressure distributions in vacuum chambers of any arbitrary geometry and cross sections of a recharge of ions in exchange reactions by electrons with molecules of residual gas in a wide range of energies and masses of ions. The outcomes of simulation have provided determination of main parameters and technical requirements for the vacuum system of the DC-72 cyclotron.

  13. The high-order cyclotron modes in Fermi liquid of Q2D layered conductors

    Directory of Open Access Journals (Sweden)

    O.V.Kirichenko

    2005-01-01

    Full Text Available The propagation of electromagnetic waves in layered conductors at the presence of an external magnetic field is investigated theoretically. At certain orientations of a magnetic field concerning the layers of the conductor the collisionless absorption is absent and weakly damping collective modes can propagate even under the strong spatial dispersion. In a short-wave limit the existence of electromagnetic waves with frequencies near the cyclotron resonances is possible at an arbitrary orientation of the wave vector with respect to an external magnetic field. We have obtained the spectrum of waves with the frequencies near the cyclotron resonances of high order with regard to the Fermi-liquid interaction of the electrons.

  14. Cyclotron Lines: From Magnetic Field Strength Estimators to ...

    Indian Academy of Sciences (India)

    Chandreyee Maitra

    2017-09-12

    Sep 12, 2017 ... With forty years since the discovery of the first cyclotron line in Her X-1, there have been remarkable ... the important results related to cyclotron lines since its discovery and reviews their significance. ... context can provide, to build a complete picture for the physics of accretion and hence X-ray emission in.

  15. Ion–Cyclotron Resonance Frequency Interval Dependence on the O ...

    Indian Academy of Sciences (India)

    Solar corona—ion–cyclotron waves—coronal heating—. Vlasov equation. 1. Introduction. Heating of solar corona is still an active research area. It has recently been suggested that the ion–cyclotron resonance could play a key role in the problem of coronal heating. It is generally argued that various electromagnetic plasma ...

  16. A novel photoinduced electron transfer (PET) primer technique for rapid real-time PCR detection of Cryptosporidium spp

    Energy Technology Data Exchange (ETDEWEB)

    Jothikumar, N., E-mail: jin2@cdc.gov; Hill, Vincent R.

    2013-06-28

    Highlights: •Uses a single-labeled fluorescent primer for real-time PCR. •The detection sensitivity of PET PCR was comparable to TaqMan PCR. •Melt curve analysis can be performed to confirm target amplicon production. •Conventional PCR primers can be converted to PET PCR primers. -- Abstract: We report the development of a fluorescently labeled oligonucleotide primer that can be used to monitor real-time PCR. The primer has two parts, the 3′-end of the primer is complimentary to the target and a universal 17-mer stem loop at the 5′-end forms a hairpin structure. A fluorescent dye is attached to 5′-end of either the forward or reverse primer. The presence of guanosine residues at the first and second position of the 3′ dangling end effectively quenches the fluorescence due to the photo electron transfer (PET) mechanism. During the synthesis of nucleic acid, the hairpin structure is linearized and the fluorescence of the incorporated primer increases several-fold due to release of the fluorescently labeled tail and the absence of guanosine quenching. As amplicons are synthesized during nucleic acid amplification, the fluorescence increase in the reaction mixture can be measured with commercially available real-time PCR instruments. In addition, a melting procedure can be performed to denature the double-stranded amplicons, thereby generating fluorescence peaks that can differentiate primer dimers and other non-specific amplicons if formed during the reaction. We demonstrated the application of PET-PCR for the rapid detection and quantification of Cryptosporidium parvum DNA. Comparison with a previously published TaqMan® assay demonstrated that the two real-time PCR assays exhibited similar sensitivity for a dynamic range of detection of 6000–0.6 oocysts per reaction. PET PCR primers are simple to design and less-expensive than dual-labeled probe PCR methods, and should be of interest for use by laboratories operating in resource

  17. The asynchronous rapid single-flux quantum electronics ─ a promising alternative for the development of high-performance digital circuits

    Directory of Open Access Journals (Sweden)

    S. Terzieva

    2008-05-01

    Full Text Available In this paper, we investigate the application of the asynchronous logic approach for the realization of ultra high-speed digital electronics with high complexity. We evaluate the possible physical, technological, and schematical origins of restrictions limiting such an application, and propose solutions for their overcoming. Although our considerations are based on the rapid single-flux quantum technique, the conclusions derived can be generalized about any type of digital information coding.

  18. STEREO and Wind Observations of Intense Cyclotron Harmonic Waves at the Earth's Bow Shock and Inside the Magnetosheath

    Science.gov (United States)

    Breneman, A. W.; Cattell, C.

    2013-01-01

    We present the first observations of electron cyclotron harmonic waves at the Earth's bow shock from STEREO and Wind burst waveform captures. These waves are observed at magnetic field gradients at a variety of shock geometries ranging from quasi-parallel to nearly perpendicular along with whistler mode waves, ion acoustic waves, and electrostatic solitary waves. Large amplitude cyclotron harmonic waveforms are also observed in the magnetosheath in association with magnetic field gradients convected past the bow shock. Amplitudes of the cyclotron harmonic waves range from a few tens to more than 500 millivolts/meter peak-peak. A comparison between the short (15 meters) and long (100 meters) Wind spin plane antennas shows a similar response at low harmonics and a stronger response on the short antenna at higher harmonics. This indicates that wavelengths are not significantly larger than 100 meters, consistent with the electron cyclotron radius. Waveforms are broadband and polarizations are distinctively comma-shaped with significant power both perpendicular and parallel to the magnetic field. Harmonics tend to be more prominent in the perpendicular directions. These observations indicate that the waves consist of a combination of perpendicular Bernstein waves and field-aligned waves without harmonics. A likely source is the electron cyclotron drift instability which is a coupling between Bernstein and ion acoustic waves. These waves are the most common type of high-frequency wave seen by STEREO during bow shock crossings and magnetosheath traversals and our observations suggest that they are an important component of the high-frequency turbulent spectrum in these regions.

  19. Electron cyclotron resonance heating in a short cylindrical plasma ...

    Indian Academy of Sciences (India)

    produced plasmas are still not well-investigated. To study these ECR-produced plasmas ... Section 4 contains the presentation and interpretation of the main experimental results. Section 5 contains the discussion and the final conclusion. 2.

  20. Characteristics of electron cyclotron resonance plasma formed by ...

    Indian Academy of Sciences (India)

    m3. When the ECR appears .... capacitor bank power supply assisted by ECR plasma, formed by LHCD system. The main parameters of the ..... voltage is gradually decreased from shot to shot, till the discharge ceases to form. We refer these ...

  1. Characteristics of electron cyclotron resonance plasma formed by ...

    Indian Academy of Sciences (India)

    2015-11-27

    Nov 27, 2015 ... The RF powe r, up to 10 kW (of which ∼ 50% is reflected back), with a typical pulse length of 50 ms, is injected into the vacuum chamber of the ADITYA tokamak by a LHCD grill antenna and is used for plasma formation. The average coupled RF power density (the RF power/a typical volume of the plasma) ...

  2. Theory of the Quasi-Optical Electron Cyclotron Maser.

    Science.gov (United States)

    1980-12-02

    D.C. 20545 Los Angeles, CA 90024 38 I . . .. .. . .. .". l ’@ .... . . . . .. .... Defense Technical Information Center Dr. Edvard A. Frieman (12 copies...Center Code 421 P. 0. Box 4349 Office of Naval Research Stanford, CA 94305 Arlington, VA 22217 Dr. Jesper Munch Dr. Charles Planner TRW Rutherford High

  3. Characteristics of the KVI electron cyclotron resonance ion source

    NARCIS (Netherlands)

    Kremers, HR; Beijers, JPM; Brandenburg, S

    In this article, an update will be given of last year's activities to modify the CAPRICE-type ECR ion source into an AECR-type ECR ion source as developed in Berkely, Argonne and Jyvaskyla. Here we will present measurements on the radial and the axial magnetic field, the vacuum system, report on the

  4. Superconducting magnets for the RAON electron cyclotron resonance ion source.

    Science.gov (United States)

    Choi, S; Kim, Y; Hong, I S; Jeon, D

    2014-02-01

    The RAON linear accelerator of Rare Isotope Science Project has been developed since 2011, and the superconducting magnet for ECRIS was designed. The RAON ECR ion source was considered as a 3rd generation source. The fully superconducting magnet has been designed for operating using 28 GHz radio frequency. The RAON ECRIS operates in a minimum B field configuration which means that a magnetic sextupole field for radial confinement is superimposed with a magnetic mirror field for axial confinement. The highest field strength reaches 3.5 T on axis and 2 T at the plasma chamber wall for operating frequency up to 28 GHz. In this paper, the design results are presented of optimized superconducting magnet consisting of four solenoids and sextupole. The prototype magnet for ECRIS was fabricated and tested to verify the feasibility of the design. On the basis of test results, a fully superconducting magnet will be fabricated and tested.

  5. Cherenkov-cyclotron instability in a metamaterial loaded waveguide for high power generation

    Science.gov (United States)

    Lu, Xueying; Shapiro, Michael; Temkin, Richard

    2017-10-01

    This work presents the analytical theory for an S-band high power microwave experiment at MIT utilizing a metamaterial (MTM) structure. A 490 kV, 84 A electron beam travels through a rectangular waveguide loaded with two MTM plates in a DC magnetic field B0. The excited waveguide mode is deflecting with a transverse E field on beam axis. Microsecond long megawatt level microwave pulses were generated under a low B0 in the Cherenkov-cyclotron type of interaction. A linear theory has been developed to explain the high power generation due to the Cherenkov-cyclotron instability. The simplified model is a planar waveguide filled with a double negative dispersive medium, and in the mode being studied, the longitudinal E field has an antisymmetric pattern in the direction perpendicular to the MTM plates. We have proved that the Cherenkov-cyclotron instability can happen with a zero initial transverse beam velocity when B0 is below a threshold. Also this instability is a unique feature of the left-handed MTM, since it requires a propagating mode below the cut-off frequency. The minimum beam current to start the instability is calculated, and the scaling law different from that of the traditional backward wave oscillators operated by longitudinal bunching will be discussed. This research was supported by the Air Force Office of Scientific Research within the Multidisciplinary University Research Initiative under Grant No. FA9550-12-1-0489 through the University of New Mexico.

  6. Ion cyclotron and spin-flip emissions from fusion products in tokamaks

    Energy Technology Data Exchange (ETDEWEB)

    Arunasalam, V.; Greene, G.J.; Young, K.M.

    1993-02-01

    Power emission by fusion products of tokamak plasmas in their ion cyclotron range of frequencies (ICRF) and at their spin-flip resonance frequency is calculated for some specific model fusion product velocity-space distribution functions. The background plasma of say deuterium (D) is assumed to be in equilibrium with a Maxwellian distribution both for the electrons and ions. The fusion product velocity distributions analyzed here are: (1) A monoenergetic velocity space ring distribution. (2) A monoenergetic velocity space spherical shell distribution. (3) An anisotropic Maxwellian distribution with T {perpendicular} {ne} T{parallel}and with appreciable drift velocity along the confining magnetic field. Single ``dressed`` test particle spontaneous emission calculations are presented first and the radiation temperature for ion cyclotron emission (ICE) is analyzed both for black-body emission and nonequilibrium conditions. Thresholds for instability and overstability conditions are then examined and quasilinear and nonlinear theories of the electromagnetic ion cyclotron modes are discussed. Distinctions between ``kinetic or causal instabilities`` and ``hydrodynamic instabilities`` are drawn and some numerical estimates are presented for typical tokamak parameters. Semiquantitative remarks are offered on wave accessibility, mode conversion, and parametric decay instabilities as possible for spatially localized ICE. Calculations are carried out both for k{parallel} = 0 for k{parallel} {ne} 0. The effects of the temperature anisotropy and large drift velocities in the parallel direction are also examined. Finally, proton spin-flip resonance emission and absorption calculations are also presented both for thermal equilibrium conditions and for an ``inverted`` population of states.

  7. High-current cyclotron to drive an electronuclear assembly

    CERN Document Server

    Alenitsky, Yu G

    2002-01-01

    The proposal on creation of a high-current cyclotron complex for driving an electronuclear assembly reported at the 17th Meeting on Accelerators of Charged Particles is discussed. Some changes in the basic design parameters of the accelerator are considered in view of new results obtained in the recent works. It is shown that the cyclotron complex is now the most real and cheapest accelerator for production of proton beams with a power of up to 10 MW. Projects on design of a high-current cyclotron complex for driving an electronuclear subcritical assembly are presented.

  8. Improving cancer treatment with cyclotron produced radionuclides. Progress report

    Energy Technology Data Exchange (ETDEWEB)

    Larson, S.M.; Finn, R.D.

    1993-11-01

    This report describes our continuing long term goal of promoting nuclear medicine applications by improving the scientific basis for tumor diagnosis, treatment and treatment follow-up based on the use of cyclotron produced radiotracers in oncology. The program includes 3 interactive components: Radiochemistry/Cyclotron; Pharmacology; and Immunology. An essential strategy is as follows: novel radionuclides and radiotracers developed in the Radiochemistry/Cyclotron section will be employed in the Pharmacology and Immunology sections during the next year. The development of novel radionuclides and tracers is of course useful in and of itself, but their utility is greatly enhanced by the interaction with the immunology and pharmacology components of the program.

  9. Shielding design of the Mayo Clinic Scottsdale cyclotron vault

    Directory of Open Access Journals (Sweden)

    Riper Kenneth A. Van

    2017-01-01

    Full Text Available Mayo Clinic Scottsdale (Scottsdale, Arizona is building a cyclotron vault containing a cyclotron with adjacent targets and a beam line leading to an external target. The targets are irradiated by high energy (15 to 16.5 MeV protons for the production of radioisotopes. We performed Monte Carlo radiation transport simulations to calculate the radiation dose outside of the vault during irradiation of the cyclotron and external targets. We present the Monte Carlo model including the geometry, sources, and variance reduction methods. Mesh tallies surrounding the vault show the external dose rate is within acceptable limits.

  10. Radiation Monitoring System of 30 MeV Cyclotron

    Directory of Open Access Journals (Sweden)

    Lee Jin-Woo

    2017-01-01

    Full Text Available A state-of-the-art radiation monitoring system was implemented at KAERI for a 30-MeV cyclotron. This system consists of several types of radiation measuring systems for ambient dose equivalent rate measurements of outside photon and neutron areas as well as inside the cyclotron, and monitors the alpha and beta particulates released from a stack, as well as the results of worker contamination at the portal of the cyclotron. In addition, an automatic alarm system is also mounted if there are alarms in the measuring systems.

  11. High-Resolution Ion Cyclotron Mobility Spectrometry

    Science.gov (United States)

    Merenbloom, Samuel I.; Glaskin, Rebecca S.; Henson, Zachary B.; Clemmer, David E.

    2009-01-01

    A novel ion mobility spectrometry instrument incorporating a cyclotron geometry drift tube is presented. The drift tube consists of eight regions, four curved drift tubes and four ion funnels. Packets of ions are propagated around the drift tube by changing the drift field at a frequency that is resonant with the ion’s drift time through each region. The approach trims each packet of ions as it leaves and enters each new region. An electrostatic gate allows ions to be kept in the drift tube for numerous cycles, increasing the ability to resolve specified ions. We demonstrate the approach by isolating the [M+2H]2+ or [M+3H]3+ charge state of substance P as well as individual trisaccharide isomers from a mixture of melezitose and raffinose. Resolving powers in excess of 300 are obtainable with this approach. PMID:19143495

  12. Simulation of cyclotron resonant scattering features

    Directory of Open Access Journals (Sweden)

    Schwarm Fritz-Walter

    2014-01-01

    Full Text Available X-ray binary systems consisting of a mass donating optical star and a highly magnetized neutron star, under the right circumstances, show quantum mechanical absorption features in the observed spectra called cyclotron resonant scattering features (CRSFs. We have developed a simulation to model CRSFs using Monte Carlo methods. We calculate Green’s tables which can be used to imprint CRSFs to arbitrary X-ray continua. Our simulation keeps track of scattering parameters of individual photons, extends the number of variable parameters of previous works, and allows for more flexible geometries. Here we focus on the influence of bulk velocity of the accreted matter on the CRSF line shapes and positions.

  13. Ion cyclotron emission by spontaneous emission

    Energy Technology Data Exchange (ETDEWEB)

    Da Costa, O. [Commission of the European Communities, Abingdon (United Kingdom). JET Joint Undertaking; Gresillon, D. [Ecole Polytechnique, 91 - Palaiseau (France). Lab. de Physique des Milieux Ionises

    1994-07-01

    The goal of the study is to examine whether the spontaneous emission can account for ICE (ion cyclotron emission) experimental results, or part of them. A straightforward approach to plasma emission is chosen, investigating the near equilibrium wave radiation by gyrating ions, and thus building from the majority and fast fusion ions the plasma fluctuations and emission on the fast magnetoacoustic or compressional Alfven wave mode in the IC frequency range. Similarities with the ICE experiments are shown: the emission temperature in the presence of fast ions (even in a very small amount), the strong fast ion emission increase with the harmonic, the fine double-line splitting of each peak, the linear but not proportional increase of the peak width with the harmonic. 3 refs., 2 figs.

  14. Stimulated Raman up-conversion of electromagnetic waves by a gyrating electron beam

    Science.gov (United States)

    Sharma, O. P.; Patel, V. L.

    1983-01-01

    A gyrating electron beam supports negative energy modes near the harmonics of electron-cyclotron frequency. An electromagnetic wave passing through such a beam parametrically up-converts into high-frequency electromagnetic modes separated from the pump frequency by the electron-cyclotron harmonics. The growth rate for this process varies directly as the oscillatory velocity of beam electrons caused by the pump and as square root of the beam density. It has a maximum at values of scattering angle close to 180 deg and is also implicitly dependent on the beam veocity and the cyclotron frequency of electrons. The effect of a cold electron component is to reduce the growth rate.

  15. An Investigation of (Diacetoxyiodo)arenes as Precursors for Preparing No-Carrier-Added [(18)F]Fluoroarenes from Cyclotron-Produced [(18)F]Fluoride Ion.

    Science.gov (United States)

    Haskali, Mohammad B; Telu, Sanjay; Lee, Yong-Sok; Morse, Cheryl L; Lu, Shuiyu; Pike, Victor W

    2016-01-04

    Treatment of (diacetoxyiodo)arenes (1a-1u) with cyclotron-produced [(18)F]fluoride ion rapidly affords no-carrier-added [(18)F]fluoroarenes (2a-2u) in useful yields and constitutes a new method for converting substituted iodoarenes into substituted [(18)F]fluoroarenes in just two steps.

  16. ECE imaging of electron temperature and electron temperature fluctuations (invited)

    NARCIS (Netherlands)

    Deng, B.H.; Domier, C.W.; N C Luhmann Jr.,; Brower, D.L.; Cima, G.; Donne, A. J. H.; Oyevaar, T.; van de Pol, M.J.

    2001-01-01

    Electron cyclotron emission imaging (ECE imaging or ECEI) is a novel plasma diagnostic technique for the study of electron temperature profiles and fluctuations in magnetic fusion plasma devices. Instead of a single receiver located in the tokamak midplane as in conventional ECE radiometers, ECEI

  17. Modeling whistler wave generation regimes in magnetospheric cyclotron maser

    Directory of Open Access Journals (Sweden)

    D. L. Pasmanik

    2004-11-01

    Full Text Available Numerical analysis of the model for cyclotron instability in the Earth's magnetosphere is performed. This model, based on the self-consistent set of equations of quasi-linear plasma theory, describes different regimes of wave generation and related energetic particle precipitation. As the source of free energy the injection of energetic electrons with transverse anisotropic distribution function to the interaction region is considered. A parametric study of the model is performed. The main attention is paid to the analysis of generation regimes for different characteristics of energetic electron source, such as the shape of pitch angle distributions and its intensity. Two mechanisms of removal of energetic electrons from a generation region are considered, one is due to the particle precipitation through the loss cone and another one is related to the magnetic drift of energetic particles.

    It was confirmed that two main regimes occur in this system in the presence of a constant particle source, in the case of precipitation losses. At small source intensity relaxation oscillations were found, whose parameters are in good agreement with simplified analytical theory developed earlier. At a larger source intensity, transition to a periodic generation occurs. In the case of drift losses the regime of self-sustained periodic generation regime is realized for source intensity higher than some threshold. The dependencies of repetition period and dynamic spectrum shape on the source parameters were studied in detail. In addition to simple periodic regimes, those with more complex spectral forms were found. In particular, alteration of spikes with different spectral shape can take place. It was also shown that quasi-stationary generation at the low-frequency band can coexist with periodic modulation at higher frequencies.

    On the basis of the results obtained, the model for explanation of

  18. High current DC negative ion source for cyclotron.

    Science.gov (United States)

    Etoh, H; Onai, M; Aoki, Y; Mitsubori, H; Arakawa, Y; Sakuraba, J; Kato, T; Mitsumoto, T; Hiasa, T; Yajima, S; Shibata, T; Hatayama, A; Okumura, Y

    2016-02-01

    A filament driven multi-cusp negative ion source has been developed for proton cyclotrons in medical applications. In Cs-free operation, continuous H(-) beam of 10 mA and D(-) beam of 3.3 mA were obtained stably at an arc-discharge power of 3 kW and 2.4 kW, respectively. In Cs-seeded operation, H(-) beam current reached 22 mA at a lower arc power of 2.6 kW with less co-extracted electron current. The optimum gas flow rate, which gives the highest H(-) current, was 15 sccm in the Cs-free operation, while it decreased to 4 sccm in the Cs-seeded operation. The relationship between H(-) production and the design/operating parameters has been also investigated by a numerical study with KEIO-MARC code, which gives a reasonable explanation to the experimental results of the H(-) current dependence on the arc power.

  19. Neutron field inside a PET Cyclotron vault room

    Energy Technology Data Exchange (ETDEWEB)

    Vega C, H.R. [UAZ, C. Cipres 10, 98068 Zacatecas (Mexico); Mendez, R. [CIEMAT, Ave. Complutense 22, 28040 Madrid (Spain); Iniguez, M.P. [Universidad de Valladolid, Po Prado de la Magdalena s/n, 47011 Valladolid (Spain); Climent, J.M.; Penuelas, I. [Servicio de Medicina Nuclear de la Clinica Universitaria de Navarra, Pamplona (Spain); Barquero, R. [Hospital Universitario Rio Hortega, Valladolid (Spain)]. e-mail: fermineutron@yahoo.com

    2006-07-01

    The neutron field around a Positron Emission Tomography cyclotron was investigated during {sup 18} F radioisotope production with an 18 MeV proton beam. In this study the Ion Beam Application cyclotron, model Cyclone 18/9, was utilized. Measurements were carried out with a Bonner sphere neutron spectrometer with pairs of thermoluminescent dosemeters (TLD600 and TLD700) as thermal neutron detector. The TLDs readouts were utilized to unfold the neutron spectra at three different positions inside the cyclotron's vault room. With the spectra the Ambient dose equivalent was calculated. Neutron spectra unfolding were performed with the BUNKIUT code and the UTA4 response matrix. Neutron spectra were also determined by Monte Carlo calculations using a detailed model of cyclotron and vault room. (Author)

  20. Vacuum Control Systems of the Cyclotrons in VECC, Kolkata

    Science.gov (United States)

    Roy, Anindya; Akhtar, Javed; Yadav, R. C.; Bhole, R. B.; Pal, Sarbajit; Sarkar, D.; Bhandari, R. K.

    2012-11-01

    VECC has undertaken the modernization of the K-130 Room Temperature Cyclotron (RTC) (operational since 1978) and commissioning of K-500 Superconducting Cyclotron (SCC) at present. The control system of RTC vacuum system has been upgraded to Programmable Logic Controller (PLC) based automated system from relay based manual system. A distributed PLC based system is under installation for SCC vacuum system. The requirement of high vacuum in both the cyclotrons (1×10-6 mbar for RTC and 5 × 10-8 mbar SCC) imposes the reliable local and remote operation of all vacuum components and instrumentation. The design and development of the vacuum control system of two cyclotrons using the Experimental Physics and Industrial Control System (EPICS) distributed real-time software tools are presented.

  1. Maryland University sectored isochronous cyclotron (MUSIC): Progress report No. 23

    Energy Technology Data Exchange (ETDEWEB)

    1967-10-09

    Progress is reported in the design, installation of various components of the cyclotron, including coils, magnets, rf system, and vacuum system. Also reported are measurements on magnets and rf components. (LEW)

  2. Maryland University sectored isochronous cyclotron (MUSIC): Progress report No. 20

    Energy Technology Data Exchange (ETDEWEB)

    1967-06-30

    Progress is reported in the fabrication and testing of cyclotron components, including magnet system and rf system components. Work on vacuum components and instrumentation and control equipment is also reported. (LEW)

  3. Maryland University sectored isochronous cyclotron (MUSIC): Progress report No. 32

    Energy Technology Data Exchange (ETDEWEB)

    1968-06-28

    Completion of magnet tests, followed by completion of installation of major cyclotron components, are reported. Intermediate level power tests of the rf system are also reported. Design and fabrication of the control system are reported to be under way. (LEW)

  4. Maryland University sectored isochronous cyclotron (MUSIC): Progress report No. 26

    Energy Technology Data Exchange (ETDEWEB)

    1968-01-17

    Progress is reported in the fabrication, installation, and testing of cyclotron components, including magnets and coils, rf components, vacuum and control equipment. Also reported are magnet and rf component measurements. (LEW)

  5. Cryogenic system for VECC K500 superconducting cyclotron

    CERN Document Server

    Pal, G; Bhattacharyya, T K; Bhandari, R K

    2009-01-01

    VEC Centre, Kolkata in India is at an advanced stage of commissioning a K500 superconducting cyclotron. The superconducting coil of the magnet for cyclotron is cooled by liquid helium. Three liquid helium cooled cryopanels, placed inside the Dees of the radiofrequency system, maintain the vacuum in the acceleration region of the superconducting cyclotron. The cryogenic system for magnet for cyclotron has been tested by cooling the coil and energizing the magnet. The cryogenic system for cryopanels has also been tested. Heater and temperature sensor were placed on the liquid helium cold head for cryopanel. The temperature of the cold head was observed to be below 20 K upto a heat load of 11.7 watt.

  6. Design of 10 MeV cyclotron accelerator

    Directory of Open Access Journals (Sweden)

    R Solhju

    2015-09-01

    Full Text Available Design and construction of 10MeV cyclotron has been started at Amirkabir University of Technology since 2012. So far, the conceptual and detail engineering design phases have been finalized. The main purpose of this baby cyclotron is to generate proton beam for the production of PET radioisotopes. The cyclotron consists of magnet, cavity, ion source, RF and LLRF system, vacuum system, cooling system, power amplifiers and power supplies system. In this paper, a brief of design principles for all the parts of cyclotron and their final simulation results is presented. It should be noted that these simulations have been performed and optimized by the most accurate softwares such as TOSCA, ANSYS, HFSS, SolidWorks and CST. Also, the manufacturing feasibility of all the parts is performed and their dimensions and parameters are synchronized with manufacturing standards

  7. Ion-Beam-Excited Electrostatic Ion Cyclotron Waves

    DEFF Research Database (Denmark)

    Michelsen, Poul; Pécseli, Hans; Juul Rasmussen, Jens

    1976-01-01

    Self-excited electrostatic ion cyclotron waves were observed in an ion-beam-plasma system produced in a DP-operated Q-machine. The frequency of the waves showed the theoretically predicted variation with the magnetic field.......Self-excited electrostatic ion cyclotron waves were observed in an ion-beam-plasma system produced in a DP-operated Q-machine. The frequency of the waves showed the theoretically predicted variation with the magnetic field....

  8. PET computer programs for use with the 88-inch cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Gough, R.A.; Chlosta, L.

    1981-06-01

    This report describes in detail several offline programs written for the PET computer which provide an efficient data management system to assist with the operation of the 88-Inch Cyclotron. This function includes the capability to predict settings for all cyclotron and beam line parameters for all beams within the present operating domain of the facility. The establishment of a data base for operational records is also described from which various aspects of the operating history can be projected.

  9. Pre-treatment verification of RapidArc® using Electronic Portal Imaging Device; Verificacao pre-tratamento de RapidArc® utilizando Dispositivo Eletronico de Imagem Porta

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Marilia B.; Ferreira, Anne Caroline M.; Bittencourt, Guilherme R.; Pirani, Luis F.; Silveira, Thiago B., E-mail: mbeckerlima@gmail.com [Instituto Nacional do Cancer (INCA), Rio de Janeiro, RJ (Brazil)

    2012-12-15

    The RapidArc® is a novel but widespread technique to achieve intensity modulated beams. One of the major challenges concerning this technique is the pretreatment verification process. The aim of this paper was to analyze the viability of the Electronic Portal Imaging Device (EPID) used to perform the verification of RapidArc® using the Sun Nuclear SNC Patient software enable to EPID dose conversion (EPIDose license) and compare its results with punctual dose measurements against a low volume ion chamber. There were analyze five RapidArc® planning, evaluating, separately, planar and punctual doses for each arc. For punctual measurements was used a 0,15 cm³ volume ion chamber and the planar distributions, in Calibration Units (CU), were acquired using the EPID and then converted to absolute dose in centigray through EPIDose. The predicted doses were calculated using the AAA algorithm in Eclipse treatment planning system, version 8.6. The planar comparisons, performed in SNC Patient, employed the Gamma Index tool with a 4% dose difference, 4 mm distance to agreement and 20% threshold. The evaluation of punctual dose was defined by calculating deviations between predicted and measured doses. The mean approval percentage in planar distributions was 94.8% and the average deviation in punctual dose was -1.2%. The use of EPID for RapidArc® pre-treatment verification proved to be feasible and showed good sensibility, because of its high spatial resolution. However one must consider the uncertainty of the method. (author)

  10. Observations of compound sawteeth in ion cyclotron resonant heating plasma using ECE imaging on experimental advanced superconducting tokamak

    Science.gov (United States)

    Hussain, Azam; Zhao, Zhenling; Xie, Jinlin; Zhu, Ping; Liu, Wandong; Ti, Ang

    2016-04-01

    The spatial and temporal evolutions of compound sawteeth were directly observed using 2D electron cyclotron emission imaging on experimental advanced superconducting tokamak. The compound sawtooth consists of partial and full collapses. After partial collapse, the hot core survives as only a small amount of heat disperses outwards, whereas in the following full collapse a large amount of heat is released and the hot core dissipates. The presence of two q = 1 surfaces was not observed. Instead, the compound sawtooth occurs mainly at the beginning of an ion cyclotron resonant frequency heating pulse and during the L-H transition phase, which may be related to heat transport suppression caused by a decrease in electron heat diffusivity.

  11. Use of an electronic-nose device for profiling headspace volatile metabolites to rapidly identify phytopathogenic microbes [Abstract].

    Science.gov (United States)

    A. Dan Wilson; D.G. Lester

    1997-01-01

    A new electronic-nose device (AromaScan A32S), consisting of an organic matrix-coated polymer-type 32-detector array, was tested as a novel tool for the detection, identification, and discrimination of phytopathogenic microbes. The sensor array detects the unique mixture of volatile metabolites released by microbes growing on standardized growth media by measuring...

  12. A real-time beam-profile monitor for a PET cyclotron

    Science.gov (United States)

    Hoehr, C.; Uittenbosch, T.; Verzilov, V.; English, W.; Buckley, K.; Gray, D.; Kellog, S.; Cameron, D.; Schaffer, P.

    2012-12-01

    Beam profiles in medical cyclotrons are traditionally measured using techniques that do not provide any information about short-term fluctuations of the beam shape or beam intensity. To overcome this, we have developed a real-time harp beam profile monitor which can withstand beam power in excess of 300 W. The monitor and electronics were constructed and applied toward a 13 MeV proton beam with current of up to 25 μA. Herein are reported preliminary beam-profile measurement results.

  13. Ion source and injection line for high intensity medical cyclotron.

    Science.gov (United States)

    Jia, XianLu; Guan, Fengping; Yao, Hongjuan; Zhang, TianJue; Yang, Jianjun; Song, Guofang; Ge, Tao; Qin, Jiuchang

    2014-02-01

    A 14 MeV high intensity compact cyclotron, CYCIAE-14, was built at China Institute of Atomic Energy (CIAE). An injection system based on the external H- ion source was used on CYCIAE-14 so as to provide high intensity beam, while most positron emission tomography cyclotrons adopt internal ion source. A beam intensity of 100 μA/14 MeV was extracted from the cyclotron with a small multi-cusp H- ion source (CIAE-CH-I type) and a short injection line, which the H- ion source of 3 mA/25 keV H- beam with emittance of 0.3π mm mrad and the injection line of with only 1.2 m from the extraction of ion source to the medial plane of the cyclotron. To increase the extracted beam intensity of the cyclotron, a new ion source (CIAE-CH-II type) of 9.1 mA was used, with maximum of 500 μA was achieved from the cyclotron. The design and test results of the ion source and injection line optimized for high intensity acceleration will be given in this paper.

  14. Geonium "K" experiment using spin dependency of cyclotron frequency supports g data of earlier geonium "S" work.

    OpenAIRE

    Mittleman, R; Palmer, F; Gabrielse, G.; Dehmelt, H.

    1991-01-01

    By substituting the relativistic spin state dependence of the cyclotron frequency for the continuous Stern-Gerlach effect and running the geonium atom as a microsynchrocyclotron accelerator we have detected spin flips of the individual trapped electron. In our initial efforts we have been able to obtain a simple symmetric spin resonance about 4-fold narrower instead of a complex asymmetric one and also to support but not as yet seriously test the result of the earlier geonium "S" work, g/2 = ...

  15. Electromagnetic cyclotron waves near the proton cyclotron frequency in the solar wind

    Science.gov (United States)

    Jian, Lan K.; Boardsen, Scott; Moya, Pablo; Stevens, Michael; Alexander, Robert; Vinas, Adolfo

    2015-04-01

    Strong narrow-band electromagnetic waves around the proton cyclotron frequency (fpc) have been found sporadically in the solar wind from 0.3 to 0.7 AU during MESSENGER spacecraft’s cruise phase. These waves are transverse and circularly polarized, and they propagate in directions quasi-parallel to the magnetic field. The wave power decreases quadratically with heliocentric distance, faster than the trend if assuming the conservation of Poynting flux for wave packets, suggesting there is energy dissipation from the waves, which could contribute to the heating and acceleration of solar wind plasma. Although the wave frequency is a few times of fpc in the spacecraft frame, it is a fraction of fpc in the solar wind plasma frame after removing the Doppler shift effect. In this frequency range, the waves can be left-hand (LH) polarized ion cyclotron waves or right-hand (RH) polarized magnetosonic waves. Because the waves are LH or RH polarized in the spacecraft frame with otherwise nearly identical characteristics, they could be due to Doppler shift of a same type of waves or a mixture of waves with intrinsically different polarizations. Through the assistance of audification, we have studied the long-lasting wave events in 2005 using high-cadence magnetic field data from the Wind mission. Statistically, in contrast with general solar wind, the protons at these waves are distributed closer to the proton instability thresholds, while the alpha particles at these waves are distributed further away from the alpha instability thresholds. For selected events of extensive waves, the ion distribution is analyzed in detail. A mixture of temperature anisotropies for core protons, beam protons, and alpha particles, as well as proton beam drift are often found in such events. We conduct linear wave dispersion analysis using these ion moments to examine whether these waves can be explained by the local generation of kinetic instabilities such as the LH ion cyclotron, the RH

  16. The detection of discrete cyclotron emission features in phase-resolved optical spectroscopy of V1500 Cygni

    Science.gov (United States)

    Harrison, Thomas E.; Campbell, Ryan K.

    2018-02-01

    We have obtained phase-resolved optical spectroscopy of the old nova and asynchronous polar V1500 Cyg. These new data reveal discrete cyclotron humps from two different strength magnetic fields. One region has B = 72 MG, while the other has B ≃ 105 MG. With the detection of these features, we revisit the optical/near-infrared light curves presented in Harrison & Campbell, and find that the large photometric excesses observed in those data are fully reconcilable with cyclotron emission. These results, when combined with the X-ray observations that appeared to have maxima that repeated on the orbital period, imply that V1500 Cyg has reverted back to a synchronous polar. Using existing theory, we show that the strong field strengths found here can explain the rapid spin-down time.

  17. Determination of crystal growth rates during rapid solidification of polycrystalline aluminum by nano-scale spatio-temporal resolution in situ transmission electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Zweiacker, K., E-mail: Kai@zweiacker.org; Liu, C.; Wiezorek, J. M. K. [Department of Mechanical Engineering and Materials Science, University of Pittsburgh, 648 Benedum Hall, 3700 OHara Street, Pittsburgh, Pennsylvania 15261 (United States); McKeown, J. T.; LaGrange, T.; Reed, B. W.; Campbell, G. H. [Materials Science Division, Physical and Life Science Directorate, Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, California 94551 (United States)

    2016-08-07

    In situ investigations of rapid solidification in polycrystalline Al thin films were conducted using nano-scale spatio-temporal resolution dynamic transmission electron microscopy. Differences in crystal growth rates and asymmetries in melt pool development were observed as the heat extraction geometry was varied by controlling the proximity of the laser-pulse irradiation and the associated induced melt pools to the edge of the transmission electron microscopy support grid, which acts as a large heat sink. Experimental parameters have been established to maximize the reproducibility of the material response to the laser-pulse-related heating and to ensure that observations of the dynamical behavior of the metal are free from artifacts, leading to accurate interpretations and quantifiable measurements with improved precision. Interface migration rate measurements revealed solidification velocities that increased consistently from ∼1.3 m s{sup −1} to ∼2.5 m s{sup −1} during the rapid solidification process of the Al thin films. Under the influence of an additional large heat sink, increased crystal growth rates as high as 3.3 m s{sup −1} have been measured. The in situ experiments also provided evidence for development of a partially melted, two-phase region prior to the onset of rapid solidification facilitated crystal growth. Using the experimental observations and associated measurements as benchmarks, finite-element modeling based calculations of the melt pool evolution after pulsed laser irradiation have been performed to obtain estimates of the temperature evolution in the thin films.

  18. Thermal Modeling and Simulation of Electron Beam Melting for Rapid Prototyping on Ti6Al4V Alloys

    Science.gov (United States)

    Neira Arce, Alderson

    To be a viable solution for contemporary engineering challenges, the use of titanium alloys in a wider range of applications requires the development of new techniques and processes that are able to decrease production cost and delivery times. As a result, the use of material consolidation in a near-net-shape fashion, using dynamic techniques like additive manufacturing by electron beam selective melting EBSM represents a promising method for part manufacturing. However, a new product material development can be cost prohibitive, requiring the use of computer modeling and simulation as a way to decrease turnaround time. To ensure a proper representation of the EBSM process, a thermophysical material characterization and comparison was first performed on two Ti6Al4V powder feedstock materials prepared by plasma (PREP) and gas atomized (GA) processes. This evaluation comprises an evaluation on particle size distribution, density and powder surface area, collectively with the temperature dependence on properties such as heat capacity, thermal diffusivity, thermal conductivity and surface emissivity. Multiple techniques were employed in this evaluation, including high temperature differential scanning calorimetry (HT-DSC), laser flash analysis (LFA), infrared remote temperature analysis (IR-Thermography), laser diffraction, liquid and gas pycnometry using mercury and krypton adsorption respectively. This study was followed by the review of complementary strategies to simulate the temperature evolution during the EBSM process, using a finite element analysis package called COMSOL Multiphysics. Two alternatives dedicated to representing a moving heat source (electron beam) and the powder bed were developed using a step-by-step approximation initiative. The first method consisted of the depiction of a powder bed discretized on an array of domains, each one representing a static melt pool, where the moving heat source was illustrated by a series of time dependant selective

  19. Inverse ion-cyclotron damping and excitation of multiharmonic ion-cyclotron waves in the northern magnetospheric cusp

    Science.gov (United States)

    Slapak, Rikard; Gunell, Herbert; Hamrin, Maria

    2017-04-01

    We have investigated a case of inverse ion-cyclotron damping taking place in the northern terrestrial magnetospheric cusp, exciting waves at the ion-cyclotron frequency and its harmonics. Magnetosheath influx in the cusps and the effect of convection and magnetic mirroring give rise to parallel velocity shears, dvallel/dx\\perp, often associated with instabilities in the plasma and corresponding ion-cyclotron waves, whose evolution is described by a damping factor. This damping factor depends on, for example, the wave numbers and the velocity shear itself and can under certain conditions be negative, hence describing inverse damping (or wave growth). However, an additional required condition for inverse ion-cyclotron damping is a velocity shear in the magnetic field-aligned ion-bulk flow, and this condition is only met for magnetosheath influx in the northern cusp, as oppose to the southern cusp. The ion-cyclotron waves are primarily seen as peaks in the magnetic-field spectral densities, as presented by Slapak et al., [GRL (2016), doi:10.1002/2016GL071680]. The corresponding peaks in the electric-field spectral densities are not as profound, suggesting a background electric field noise or other processes of wave generation causing the electric spectral densities to smoothen out more compared to the magnetic counterpart. We note that some ion-cyclotron wave activity is present in a few similar shear events in the southern cusp, which indicates that other mechanisms generating ion-cyclotron waves may also be present during such conditions.

  20. Analysis of MMS observations of Ion Cyclotron Waves in the Magnetosheath

    Science.gov (United States)

    Boardsen, S. A.; Vinas, A. F.; Gershman, D. J.; Dorelli, J.; Bellan, P. M.; Wendel, D. E.; Avanov, L. A.; Barrie, A. C.; Giles, B. L.; Moore, T. E.; Paterson, W. R.; Pollock, C.; Le, G.; Russell, C. T.; Fuselier, S. A.; Strangeway, R. J.; Torbert, R. B.; Burch, J. L.

    2016-12-01

    We will analyze magnetosheath ion cyclotron waves observed by the Magnetospheric Multiscale (MMS) Spacecraft. One such event occurred on October 7, 2016, in which strong ion cyclotron waves were observed in the magnetosheath, near the bowshock, lasting for 1 hour. We will perform a detailed wave analysis of this and similar events, comparing and contrasting single spacecraft and multi-spacecraft analysis techniques. The later will consist of a) Balikhin's phase difference method, b) Bellan's k-spectral plasma current method, and c) k-Filtering multi-spacecraft technique. For the identified wave mode based on these techniques, the self-consistency between the ion/electron fluctuations and the electric and magnetic field fluctuations of these waves will be explored. No Fast Plasma Investigation burst mode data exists for these events, so trigger data, which is at the same temporal resolution as that of the burst mode will be used to compare the ion/electron fluctuations with that of the electric and magnetic fields

  1. A Multifunctional Mn(II) Phosphonate for Rapid Separation of Methyl Orange and Electron-Transfer Photochromism.

    Science.gov (United States)

    Gao, Chao-Ying; Yang, Yang; Ai, Jing; Tian, Hong-Rui; Li, Lei-Jiao; Yang, Weiting; Dang, Song; Sun, Zhong-Ming

    2016-08-08

    A Mn(II) phosphonate of the general formula [Mn(H2 L)2 (H2 O)2 (H2 bibp)] adopts a layered motif with protonated H2 bibp(2+) cations embedded in the channels (H4 L=thiophene-2-phosphonic acid; bibp=4,4'-bis(1-imidazolyl)biphenyl). The title compound exhibits excellent adsorptive removal of methyl orange (MO) dye from aqueous solution. Its advantageous features include fast adsorption, high uptake capacity, selective removal, and reusability, which are of great significance for practical application in wastewater treatment. Meanwhile, the compound displays rapid photochromism upon irradiation with visible light at room temperature. Extensive research has demonstrated that such behavior is based on a ligand-to-ligand charge-transfer (LLCT) mechanism. The irradiated sample possesses an ultra-long-lived charge-separated state. Moreover, not only is the compound the first Mn-based photochromic MOF, but it is also one of the very few examples showing LLCT with non-photochromic components. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Design of RF system for CYCIAE-230 superconducting cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Yin, Zhiguo, E-mail: bitbearAT@hotmail.com; Ji, Bin; Fu, Xiaoliang; Cao, Xuelong; Zhao, Zhenlu; Zhang, Tinajue

    2017-05-11

    The CYCIAE230 is a low-current, compact superconducting cyclotron designed for proton therapy. The Radio Frequency system consists of four RF cavities and applies second harmonic to accelerate beams. The driving power for the cavity system is estimated to be approximately 150 kW. The LLRF controller is a self-made device developed and tested at low power using a small-scale cavity model. In this paper, the resonator systems of an S.C. cyclotron in history are reviewed. Contrary to those RF systems, the cavities of the CYCIAE230 cyclotron connect two opposite dees. Two high-power RF windows are included in the system. Each window carries approximately 75 kW RF power from the driver to the cavities. Thus, the RF system for the CY-CIAE230 cyclotron is operated in driven push–pull mode. The two-way amplifier-coupler-cavity systems are operated with approximately the same amount of RF power but 180° out of phase compared with each other. The design, as well as the technical advantage and limitations of this operating mode, of the CYCIAE230 cyclotron RF system is analyzed.

  3. Design of RF system for CYCIAE-230 superconducting cyclotron

    Science.gov (United States)

    Yin, Zhiguo; Ji, Bin; Fu, Xiaoliang; Cao, Xuelong; Zhao, Zhenlu; Zhang, Tinajue

    2017-05-01

    The CYCIAE230 is a low-current, compact superconducting cyclotron designed for proton therapy. The Radio Frequency system consists of four RF cavities and applies second harmonic to accelerate beams. The driving power for the cavity system is estimated to be approximately 150 kW. The LLRF controller is a self-made device developed and tested at low power using a small-scale cavity model. In this paper, the resonator systems of an S.C. cyclotron in history are reviewed. Contrary to those RF systems, the cavities of the CYCIAE230 cyclotron connect two opposite dees. Two high-power RF windows are included in the system. Each window carries approximately 75 kW RF power from the driver to the cavities. Thus, the RF system for the CY-CIAE230 cyclotron is operated in driven push-pull mode. The two-way amplifier-coupler-cavity systems are operated with approximately the same amount of RF power but 180° out of phase compared with each other. The design, as well as the technical advantage and limitations of this operating mode, of the CYCIAE230 cyclotron RF system is analyzed.

  4. Risk assessment of 30 MeV cyclotron facilities

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Gyo Seong; Lee, Jin Woo [Advanced Radiation Technology Institute, Korea Atomic Energy Research Institute, Jeongeup (Korea, Republic of); Kim, Chong Yeal [Dept. of Radiation Science and Technology, Chonbuk National University, Jeonju (Korea, Republic of)

    2017-03-15

    A cyclotron is a kind of particle accelerator that produces a beam of charged particles for the production of medical, industrial, and research radioisotopes. More than 30 cyclotrons are operated in Korea to produce 18F, an FDG synthesis at hospitals. A 30-MeV cyclotron was installed at ARTI (Advanced Radiation Technology Institute, KAERI) mainly for research regarding isotope production. In this study, we analyze and estimate the items of risk such as the problems in the main components of the cyclotron, the loss of radioactive materials, the leakage of coolant, and the malfunction of utilities, fres and earthquakes. To estimate the occurrence frequency in an accident risk assessment, five levels, i.e., Almost certain, Likely, Possible, Unlikely, and Rare, are applied. The accident consequence level is classified under four grades based on the annual permissible dose for radiation workers and the public in the nuclear safety law. The analysis of the accident effect is focused on the radioactive contamination caused by radioisotope leakage and radioactive material leakage of a ventilation filter due to a free. To analyze the risks, Occupation Safety and Health Acts is applied. In addition, action plans against an accident were prepared after a deep discussion among relevant researchers. In this acts, we will search for hazard and introduce the risk assessment for the research 30-MeV cyclotron facilities of ARTI.

  5. 75 FR 48939 - National Superconducting Cyclotron Laboratory of Michigan State University; Notice of Decision on...

    Science.gov (United States)

    2010-08-12

    ... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF COMMERCE International Trade Administration National Superconducting Cyclotron Laboratory of Michigan State University...., NW., Washington, DC. Docket Number: 10-043. Applicant: National Superconducting Cyclotron Laboratory...

  6. Development of a fast scintillator based beam phase measurement system for compact superconducting cyclotrons

    Energy Technology Data Exchange (ETDEWEB)

    Bhattacharjee, Tanushyam; Kanti Dey, Malay; Dhara, Partha; Roy, Suvodeep; Debnath, Jayanta; Balakrishna Bhole, Rajendra; Dutta, Atanu; Pradhan, Jedidiah; Pal, Sarbajit; Pal, Gautam; Roy, Amitava; Chakrabarti, Alok [Variable Energy Cyclotron Centre, 1/AF Bidhannagar, Kolkata 700064 (India)

    2013-05-15

    In an isochronous cyclotron, measurements of central phase of the ion beam with respect to rf and the phase width provide a way to tune the cyclotron for maximum energy gain per turn and efficient extraction. We report here the development of a phase measurement system and the measurements carried out at the Variable Energy Cyclotron Centre's (VECC's) K= 500 superconducting cyclotron. The technique comprises detecting prompt {gamma}-rays resulting from the interaction of cyclotron ion beam with an aluminium target mounted on a radial probe in coincidence with cyclotron rf. An assembly comprising a fast scintillator and a liquid light-guide inserted inside the cyclotron was used to detect the {gamma}-rays and to transfer the light signal outside the cyclotron where a matching photo-multiplier tube was used for light to electrical signal conversion. The typical beam intensity for this measurement was a few times 10{sup 11} pps.

  7. Acceptability of using electronic vending machines to deliver oral rapid HIV self-testing kits: a qualitative study.

    Directory of Open Access Journals (Sweden)

    Sean D Young

    Full Text Available Rates of unrecognized HIV infection are significantly higher among Latino and Black men who have sex with men (MSM. Policy makers have proposed that HIV self-testing kits and new methods for delivering self-testing could improve testing uptake among minority MSM. This study sought to conduct qualitative assessments with MSM of color to determine the acceptability of using electronic vending machines to dispense HIV self-testing kits.African American and Latino MSM were recruited using a participant pool from an existing HIV prevention trial on Facebook. If participants expressed interest in using a vending machine to receive an HIV self-testing kit, they were emailed a 4-digit personal identification number (PIN code to retrieve the test from the machine. We followed up with those who had tested to assess their willingness to participate in an interview about their experience.Twelve kits were dispensed and 8 interviews were conducted. In general, participants expressed that the vending machine was an acceptable HIV test delivery method due to its novelty and convenience.Acceptability of this delivery model for HIV testing kits was closely associated with three main factors: credibility, confidentiality, and convenience. Future research is needed to address issues, such as user-induced errors and costs, before scaling up the dispensing method.

  8. Rapid and precise determination of zero-field splittings by terahertz time-domain electron paramagnetic resonance spectroscopy.

    Science.gov (United States)

    Lu, Jian; Ozel, I Ozge; Belvin, Carina A; Li, Xian; Skorupskii, Grigorii; Sun, Lei; Ofori-Okai, Benjamin K; Dincă, Mircea; Gedik, Nuh; Nelson, Keith A

    2017-11-01

    Zero-field splitting (ZFS) parameters are fundamentally tied to the geometries of metal ion complexes. Despite their critical importance for understanding the magnetism and spectroscopy of metal complexes, they are not routinely available through general laboratory-based techniques, and are often inferred from magnetism data. Here we demonstrate a simple tabletop experimental approach that enables direct and reliable determination of ZFS parameters in the terahertz (THz) regime. We report time-domain measurements of electron paramagnetic resonance (EPR) signals associated with THz-frequency ZFSs in molecular complexes containing high-spin transition-metal ions. We measure the temporal profiles of the free-induction decays of spin resonances in the complexes at zero and nonzero external magnetic fields, and we derive the EPR spectra via numerical Fourier transformation of the time-domain signals. In most cases, absolute values of the ZFS parameters are extracted from the measured zero-field EPR frequencies, and the signs can be determined by zero-field measurements at two different temperatures. Field-dependent EPR measurements further allow refined determination of the ZFS parameters and access to the g -factor. The results show good agreement with those obtained by other methods. The simplicity of the method portends wide applicability in chemistry, biology and material science.

  9. Acceptability of using electronic vending machines to deliver oral rapid HIV self-testing kits: a qualitative study.

    Science.gov (United States)

    Young, Sean D; Daniels, Joseph; Chiu, ChingChe J; Bolan, Robert K; Flynn, Risa P; Kwok, Justin; Klausner, Jeffrey D

    2014-01-01

    Rates of unrecognized HIV infection are significantly higher among Latino and Black men who have sex with men (MSM). Policy makers have proposed that HIV self-testing kits and new methods for delivering self-testing could improve testing uptake among minority MSM. This study sought to conduct qualitative assessments with MSM of color to determine the acceptability of using electronic vending machines to dispense HIV self-testing kits. African American and Latino MSM were recruited using a participant pool from an existing HIV prevention trial on Facebook. If participants expressed interest in using a vending machine to receive an HIV self-testing kit, they were emailed a 4-digit personal identification number (PIN) code to retrieve the test from the machine. We followed up with those who had tested to assess their willingness to participate in an interview about their experience. Twelve kits were dispensed and 8 interviews were conducted. In general, participants expressed that the vending machine was an acceptable HIV test delivery method due to its novelty and convenience. Acceptability of this delivery model for HIV testing kits was closely associated with three main factors: credibility, confidentiality, and convenience. Future research is needed to address issues, such as user-induced errors and costs, before scaling up the dispensing method.

  10. Calibration of the simulation model of the VINCY cyclotron magnet

    Directory of Open Access Journals (Sweden)

    Ćirković Saša

    2002-01-01

    Full Text Available The MERMAID program will be used to isochronise the nominal magnetic field of the VINCY Cyclotron. This program simulates the response, i. e. calculates the magnetic field, of a previously defined model of a magnet. The accuracy of 3D field calculation depends on the density of the grid points in the simulation model grid. The size of the VINCY Cyclotron and the maximum number of grid points in the XY plane limited by MERMAID define the maximumobtainable accuracy of field calculations. Comparisons of the field simulated with maximum obtainable accuracy with the magnetic field measured in the first phase of the VINCY Cyclotron magnetic field measurements campaign has shown that the difference between these two fields is not as small as required. Further decrease of the difference between these fields is obtained by the simulation model calibration, i. e. by adjusting the current through the main coils in the simulation model.

  11. Calibration of the simulation model of the Vincy cyclotron magnet

    CERN Document Server

    Cirkovic, S; Vorozhtsov, A S; Vorozhtsov, S B

    2002-01-01

    The MERMAID program will be used to isochronise the nominal magnetic field of the VINCY Cyclotron. This program simulates the response, i. e. calculates the magnetic field, of a previously defined model of a magnet. The accuracy of 3D field calculation depends on the density of the grid points in the simulation model grid. The size of the VINCY Cyclotron and the maximum number of grid points in the XY plane limited by MERMAID define the maximum obtainable accuracy of field calculations. Comparisons of the field simulated with maximum obtainable accuracy with the magnetic field measured in the first phase of the VINCY Cyclotron magnetic field measurements campaign has shown that the difference between these two fields is not as small as required. Further decrease of the difference between these fields is obtained by the simulation model calibration, i. e. by adjusting the current through the main coils in the simulation model.

  12. Evaluation of Titanium Alloys Fabricated Using Rapid Prototyping Technologies—Electron Beam Melting and Laser Beam Melting

    Directory of Open Access Journals (Sweden)

    Toru Okabe

    2011-10-01

    Full Text Available This study characterized properties of Ti-6Al-4V ELI (extra low interstitial, ASTM grade 23 specimens fabricated by a laser beam melting (LBM and an electron beam melting (EBM system for dental applications. Titanium alloy specimens were made into required size and shape for each standard test using fabrication methods. The LBM specimens were made by an LBM machine utilizing 20 µm of Ti-6Al-4V ELI powder. Ti-6Al-4V ELI specimens were also fabricated by an EBM using 40 µm of Ti-6Al-4V ELI powder (average diameter, 40 µm: Arcam ABÒ in a vacuum. As a control, cast Ti-6Al-4V ELI specimens (Cast were made using a centrifugal casting machine in an MgO-based mold. Also, a wrought form of Ti-6Al-4V ELI (Wrought was used as a control. The mechanical properties, corrosion properties and grindability (wear properties were evaluated and data was analyzed using ANOVA and a non-parametric method (α = 0.05. The strength of the LBM and wrought specimens were similar, whereas the EBM specimens were slightly lower than those two specimens. The hardness of both the LBM and EBM specimens was similar and slightly higher than that of the cast and wrought alloys. For the higher grindability speed at 1,250 m/min, the volume loss of Ti64 LBM and EBM showed no significant differences among all the fabrication methods. LBM and EBM exhibited favorable results in fabricating dental appliances with excellent properties as found for specimens made by other fabricating methods.

  13. Cyclotron resonant scattering feature simulations. II. Description of the CRSF simulation process

    Science.gov (United States)

    Schwarm, F.-W.; Ballhausen, R.; Falkner, S.; Schönherr, G.; Pottschmidt, K.; Wolff, M. T.; Becker, P. A.; Fürst, F.; Marcu-Cheatham, D. M.; Hemphill, P. B.; Sokolova-Lapa, E.; Dauser, T.; Klochkov, D.; Ferrigno, C.; Wilms, J.

    2017-05-01

    Context. Cyclotron resonant scattering features (CRSFs) are formed by scattering of X-ray photons off quantized plasma electrons in the strong magnetic field (of the order 1012 G) close to the surface of an accreting X-ray pulsar. Due to the complex scattering cross-sections, the line profiles of CRSFs cannot be described by an analytic expression. Numerical methods, such as Monte Carlo (MC) simulations of the scattering processes, are required in order to predict precise line shapes for a given physical setup, which can be compared to observations to gain information about the underlying physics in these systems. Aims: A versatile simulation code is needed for the generation of synthetic cyclotron lines. Sophisticated geometries should be investigatable by making their simulation possible for the first time. Methods: The simulation utilizes the mean free path tables described in the first paper of this series for the fast interpolation of propagation lengths. The code is parallelized to make the very time-consuming simulations possible on convenient time scales. Furthermore, it can generate responses to monoenergetic photon injections, producing Green's functions, which can be used later to generate spectra for arbitrary continua. Results: We develop a new simulation code to generate synthetic cyclotron lines for complex scenarios, allowing for unprecedented physical interpretation of the observed data. An associated XSPEC model implementation is used to fit synthetic line profiles to NuSTAR data of Cep X-4. The code has been developed with the main goal of overcoming previous geometrical constraints in MC simulations of CRSFs. By applying this code also to more simple, classic geometries used in previous works, we furthermore address issues of code verification and cross-comparison of various models. The XSPEC model and the Green's function tables are available online (see link in footnote, page 1).

  14. Ion cyclotron and spin-flip emissions from fusion products in tokamaks

    Energy Technology Data Exchange (ETDEWEB)

    Arunasalam, V.; Greene, G.J.; Young, K.M.

    1993-02-01

    Power emission by fusion products of tokamak plasmas in their ion cyclotron range of frequencies (ICRF) and at their spin-flip resonance frequency is calculated for some specific model fusion product velocity-space distribution functions. The background plasma of say deuterium (D) is assumed to be in equilibrium with a Maxwellian distribution both for the electrons and ions. The fusion product velocity distributions analyzed here are: (1) A monoenergetic velocity space ring distribution. (2) A monoenergetic velocity space spherical shell distribution. (3) An anisotropic Maxwellian distribution with T [perpendicular] [ne] T[parallel]and with appreciable drift velocity along the confining magnetic field. Single dressed'' test particle spontaneous emission calculations are presented first and the radiation temperature for ion cyclotron emission (ICE) is analyzed both for black-body emission and nonequilibrium conditions. Thresholds for instability and overstability conditions are then examined and quasilinear and nonlinear theories of the electromagnetic ion cyclotron modes are discussed. Distinctions between kinetic or causal instabilities'' and hydrodynamic instabilities'' are drawn and some numerical estimates are presented for typical tokamak parameters. Semiquantitative remarks are offered on wave accessibility, mode conversion, and parametric decay instabilities as possible for spatially localized ICE. Calculations are carried out both for k[parallel] = 0 for k[parallel] [ne] 0. The effects of the temperature anisotropy and large drift velocities in the parallel direction are also examined. Finally, proton spin-flip resonance emission and absorption calculations are also presented both for thermal equilibrium conditions and for an inverted'' population of states.

  15. Distribution of thermal neutron flux around a PET cyclotron.

    Science.gov (United States)

    Ogata, Yoshimune; Ishigure, Nobuhito; Mochizuki, Shingo; Ito, Kengo; Hatano, Kentaro; Abe, Junichiro; Miyahara, Hiroshi; Masumoto, Kazuyoshi; Nakamura, Hajime

    2011-05-01

    The number of positron emission tomography (PET) examinations has greatly increased world-wide. Since positron emission nuclides for the PET examinations have short half-lives, they are mainly produced using on-site cyclotrons. During the production of the nuclides, significant quantities of neutrons are generated from the cyclotrons. Neutrons have potential to activate the materials around the cyclotrons and cause exposure to the staff. To investigate quantities and distribution of the thermal neutrons, thermal neutron fluxes were measured around a PET cyclotron in a laboratory associating with a hospital. The cyclotron accelerates protons up to 18 MeV, and the mean particle current is 20 μA. The neutron fluxes were measured during both 18F production and C production. Gold foils and thermoluminescent dosimeter (TLD) badges were used to measure the neutron fluxes. The neutron fluxes in the target box averaged 9.3 × 10(6) cm(-2) s(-1) and 1.7 × 10(6) cm(-2) s(-1) during 18F and 11C production, respectively. Those in the cyclotron room averaged 4.1 × 10(5) cm(-2) s(-1) and 1.2 × 10(5) cm(-2) s(-1), respectively. Those outside the concrete wall shielding were estimated as being equal to or less than ∼3 cm s, which corresponded to 0.1 μSv h(-1) in effective dose. The neutron fluxes outside the concrete shielding were confirmed to be quite low compared to the legal limit.

  16. Design study of the large hadron electron collider and a rapid cycling synchrotron as alternative to the PS booster upgrade at CERN

    Energy Technology Data Exchange (ETDEWEB)

    Fitterer, Miriam

    2013-02-22

    With the Large Hadron Collider (LHC) the exploration of particle physics at center of mass energies at the TeV scale has begun. To extend the discovery potential of the LHC, a major upgrade is foreseen around 2020 of the LHC itself and the LHC injectors - the chain of accelerators preparing the beam for the LHC. One of the injectors - the second one in the chain - is the Proton Synchrotron (PS) Booster. Its performance is currently limited by the space-charge effect, which is the effect of the electromagnetic field of the particle beam on itself. This effect becomes weaker with higher energy, and therefore an energy upgrade of the PS Booster to 2 GeV maximum beam energy is foreseen. As the PS Booster is with its 40 years already an old machine, the construction of a new accelerator, a Rapid Cycling Synchrotron (RCS), to replace the PS Booster has been proposed. In this thesis different options for the beam guidance in the RCS - referred to as lattice and optics - are studied, followed by a more general comparison of different lattices and optics and their performance under consideration of the space-charge effect. To further complement the LHC physics program, also the possibility of deep inelastic lepton-nucleon scattering at the LHC has been suggested, referred to as Large Hadron Electron Collider (LHeC). In this case the proton beam of the LHC collides with the electron beam, which is accelerated in a separate newly built machine. Two options are considered as electron accelerator: a new energy recovery linac - the Linac-Ring option - and the installation of an electron ring in the existing LHC tunnel - the Ring-Ring option. One of the main challenges of the Ring-Ring option is the integration of the electron ring in the current LHC tunnel. A layout, lattice and optics of the electron accelerator is developed in this thesis, which meets the requirements with regard to integration and reaches the beam parameters demanded by the particle physics experiments.

  17. Immediate mandibular reconstruction via patient-specific titanium mesh tray using electron beam melting/CAD/rapid prototyping techniques: One-year follow-up.

    Science.gov (United States)

    Farid Shehab, Mohamed; Hamid, Nabila Mohammed Abdel; Askar, Nevien Abdullatif; Elmardenly, Ahmed Mokhtar

    2018-02-21

    Immediate mandibular reconstruction was performed using a patient-specific titanium mesh tray fabricated by electron beam melting (EBM) /rapid prototyping techniques. Patient-specific titanium trays were virtually designed and fabricated using EBM technology/rapid prototyping for patients requiring mandibular resection and immediate reconstruction using an iliac crest bone graft. Dental implants were placed in the grafted sites and the patients received prosthetic rehabilitation with a follow-up of one year. Clinical data, postoperative bone formation and complications were evaluated. A symmetric appearance of facial contours was achieved. The titanium tray incorporated the particulate iliac crest bone graft that provided significant bone formation (mean 18.97 ± 1.45 mm) and predictable results. Stability of the dental implants was achieved. The patient-specific titanium meshes and immediate particulate autogenous bone graft showed satisfactory clinical and surgical results in improving patients' quality of life and decreasing the overall treatment time with adequate functional rehabilitation. Copyright © 2018 John Wiley & Sons, Ltd.

  18. Electron microscopy as a reliable tool for rapid and conventional detection of enteric viral agents: a five-year experience report.

    Science.gov (United States)

    Arcangeletti, Maria Cristina; De Conto, Flora; Pinardi, Federica; Medici, Maria Cristina; Valcavi, Pierpaolo; Ferraglia, Francesca; Motta, Federica; Covan, Silvia; Calderaro, Adriana; Chezzi, Carlo; Dettori, Giuseppe

    2005-12-01

    Since the introduction of the electron microscope and its subsequent development, virology has made a great step forward by the improvement of the basic knowledge on viral structure, as well as by broad application of electron microscopy (EM) to viral diagnosis. In this report, we describe a five-year experience in the use of EM for the diagnosis of enteric viral infections. Three thousand four hundred and ninety stool specimens were analyzed at the Virology Unit (Section of Microbiology, Department of Pathology and Laboratory Medicine, University of Parma, Italy) during a five-year period, from January 1999 to January 2004. The faecal extracts were subjected to EM after negative staining and were simultaneously cultured to evidence the presence of cytopathogenic agents. EM directly applied to the above specimens allowed the detection of several enteric viral agents, particularly evidencing those normally hard to cultivate (thus easily lost with culture methods). It also enabled diagnosis of dual gut infections, such as those from rotavirus and calicivirus. On the other hand, EM-based identification of viral agents after cell culture and ultracentrifugation of cytopathogenic agent-containing cellular extracts, allowed the identification of cultivable agents, such as picornaviruses, which can escape the direct EM detection if low concentrated. A rationalized use of EM on selected samples, such as stool, appears suitable in epidemiological or clinical conditions when a very rapid diagnosis is required to save time, including cases of suspected emerging viral infections.

  19. Rapid imaging of misfit dislocations in SiGe/Si in cross-section and through oxide layers using electron channeling contrast

    Science.gov (United States)

    Mukherjee, Kunal; Wacaser, Brent A.; Bedell, Stephen W.; Sadana, Devendra K.

    2017-06-01

    Electron channeling contrast imaging (ECCI) is emerging as a technique for rapid and high-resolution characterization of individual crystalline defects in a scanning electron microscope. However, the application of ECCI to semiconductor materials has been limited to bare samples in plan-view geometry. In this paper, two modalities of this technique are demonstrated with relevance to semiconductor manufacturing and failure analysis: (1) The use of ECCI to reveal misfit dislocation defects along a cleaved cross-section of a SiGe compositionally graded buffer grown on Si and (2) plan-view imaging of misfit dislocations in metamorphic SiGe/Si layers covered by amorphous oxide layers, where the partial loss of contrast due to the oxide layers is quantified and the effect of the beam accelerating voltage is studied. These results demonstrate the power of ECCI in inspecting crystallographic defects non-destructively over large areas, which is highly desirable for substrate quality control in manufacturing of products based on crystalline materials.

  20. Doxorubicin in vivo rapidly alters expression and translation of myocardial electron transport chain genes, leads to ATP loss and caspase 3 activation.

    Directory of Open Access Journals (Sweden)

    Amy V Pointon

    Full Text Available BACKGROUND: Doxorubicin is one of the most effective anti-cancer drugs but its use is limited by cumulative cardiotoxicity that restricts lifetime dose. Redox damage is one of the most accepted mechanisms of toxicity, but not fully substantiated. Moreover doxorubicin is not an efficient redox cycling compound due to its low redox potential. Here we used genomic and chemical systems approaches in vivo to investigate the mechanisms of doxorubicin cardiotoxicity, and specifically test the hypothesis of redox cycling mediated cardiotoxicity. METHODOLOGY/PRINCIPAL FINDINGS: Mice were treated with an acute dose of either doxorubicin (DOX (15 mg/kg or 2,3-dimethoxy-1,4-naphthoquinone (DMNQ (25 mg/kg. DMNQ is a more efficient redox cycling agent than DOX but unlike DOX has limited ability to inhibit gene transcription and DNA replication. This allowed specific testing of the redox hypothesis for cardiotoxicity. An acute dose was used to avoid pathophysiological effects in the genomic analysis. However similar data were obtained with a chronic model, but are not specifically presented. All data are deposited in the Gene Expression Omnibus (GEO. Pathway and biochemical analysis of cardiac global gene transcription and mRNA translation data derived at time points from 5 min after an acute exposure in vivo showed a pronounced effect on electron transport chain activity. This led to loss of ATP, increased AMPK expression, mitochondrial genome amplification and activation of caspase 3. No data gathered with either compound indicated general redox damage, though site specific redox damage in mitochondria cannot be entirely discounted. CONCLUSIONS/SIGNIFICANCE: These data indicate the major mechanism of doxorubicin cardiotoxicity is via damage or inhibition of the electron transport chain and not general redox stress. There is a rapid response at transcriptional and translational level of many of the genes coding for proteins of the electron transport chain