WorldWideScience

Sample records for rapid color flow

  1. Multi-Frequency Encoding for Rapid Color Flow and Quadroplex Imaging

    DEFF Research Database (Denmark)

    Oddershede, Niels; Gran, Fredrik; Jensen, Jørgen Arendt

    2007-01-01

    Ultrasonic color flow maps are made by estimating the velocities line by line over the region of interest. For each velocity estimate, multiple repetitions are needed. This sets a limit on the frame rate, which becomes increasingly severe when imaging deeper lying structures or when simultaneously...... acquiring spectrogram data for triplex imaging. This paper proposes a method for decreasing the data acquisition time by simultaneously sampling multiple lines at different spatial positions for the color flow map using narrow band signals with disjoint spectral support. The signals are separated...... in the receiver by filters matched to the emitted waveforms and the autocorrelation estimator is applied. Alternatively, one spectral band can be used for creating a color flow map, while data for a number of spectrograms are acquired simultaneously. Using three disjoint spectral bands, this will result...

  2. A rapid and robust tri-color flow cytometry assay for monitoring malaria parasite development.

    Science.gov (United States)

    Malleret, Benoît; Claser, Carla; Ong, Alice Soh Meoy; Suwanarusk, Rossarin; Sriprawat, Kanlaya; Howland, Shanshan Wu; Russell, Bruce; Nosten, Francois; Rénia, Laurent

    2011-01-01

    Microscopic examination of Giemsa-stained thin blood smears remains the gold standard method used to quantify and stage malaria parasites. However, this technique is tedious, and requires trained microscopists. We have developed a fast and simple flow cytometry method to quantify and stage, various malaria parasites in red blood cells in whole blood or in vitro cultured Plasmodium falciparum. The parasites were stained with dihydroethidium and Hoechst 33342 or SYBR Green I and leukocytes were identified with an antibody against CD45. Depending on the DNA stains used, samples were analyzed using different models of flow cytometers. This protocol, which does not require any washing steps, allows infected red blood cells to be distinguished from leukocytes, as well as allowing non-infected reticulocytes and normocytes to be identified. It also allows assessing the proportion of parasites at different developmental stages. Lastly, we demonstrate how this technique can be applied to antimalarial drug testing.

  3. Rapid Color Test Identification System for Screening of Counterfeit Fluoroquinolone

    Directory of Open Access Journals (Sweden)

    B. K. Singh

    2009-01-01

    Full Text Available The protocol of rapid identification system consists of three chemical color reactions; two group tests for fluoroquinolone class and a compound specific test each for norfloxacin, ciprofloxacin, gatifloxacin, ofloxacin, levofloxacin and sparfloxacin. The group color reactions are based on (a Oxidizing behavior of quinolone and (b Fluorine functional groups, both of which are characteristic of fluoroquinolone class. The compound specific color reactions are developed taking into consideration unique chemical behavior of each compound. The proposed chemical color tests have high selectivity⁄specificity, are ideal for screening purpose. The color of each test was defined by two standard color systems namely CIE lab and Munsell color. A suspected counterfeit tablet of any of the above mentioned drugs can be identified within 10-15 min using this rapid identification system.

  4. QCD in the color-flow representation

    Energy Technology Data Exchange (ETDEWEB)

    Kilian, W. [Siegen Univ. (Germany). Fachbereich 7 - Physik; Ohl, T. [Wuerzburg Univ. (Germany). Inst. fuer Theoretische Physik und Astrophysik; Reuter, J. [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Speckner, C. [Freiburg Univ. (Germany). Physikalisches Inst.

    2012-06-15

    For many practical purposes, it is convenient to formulate unbroken nonabelian gauge theories like QCD in a color-flow basis. We present a new derivation of SU(N) interactions in the color-flow basis by extending the gauge group to U(N) x U(1)' in such a way that the two U(1) factors cancel each other. We use the quantum action principles to show the equivalence to the usual basis to all orders in perturbation theory. We extend the known Feynman rules to exotic color representations (e.g. sextets) and interactions (e.g. {epsilon}{sub ijk}). We discuss practical applications as they occur in automatic computation programs.

  5. JIMWLK evolution: From color charges to rapidity correlations

    Energy Technology Data Exchange (ETDEWEB)

    Iancu, E. [Institut de Physique Théorique de Saclay, F-91191 Gif-sur-Yvette (France); Triantafyllopoulos, D.N. [ECT* and Fondazione Bruno Kessler, Strada delle Tabarelle 286, I-38123 Villazzano (Italy)

    2014-12-15

    We study multi-particle production with rapidity correlations in high-energy p+A collisions. In the context of the Color Glass Condensate, the evolution for such correlations is governed by a generalization of the JIMWLK equation which evolves the strong nuclear fields both in the amplitude and in the complex conjugate one. We give the equivalent Langevin formulation, whose main ingredient is the color charge density linked to a projectile parton (a Wilson line)

  6. JIMWLK evolution: From color charges to rapidity correlations

    Science.gov (United States)

    Iancu, E.; Triantafyllopoulos, D. N.

    2014-12-01

    We study multi-particle production with rapidity correlations in high-energy p+A collisions. In the context of the Color Glass Condensate, the evolution for such correlations is governed by a generalization of the JIMWLK equation which evolves the strong nuclear fields both in the amplitude and in the complex conjugate one. We give the equivalent Langevin formulation, whose main ingredient is the color charge density linked to a projectile parton (a Wilson line).

  7. JIMWLK evolution: from color charges to rapidity correlations

    CERN Document Server

    Iancu, E

    2014-01-01

    We study multi-particle production with rapidity correlations in high-energy p+A collisions. In the context of the Color Glass Condensate, the evolution for such correlations is governed by a generalization of the JIMWLK equation which evolves the strong nuclear fields both in the amplitude and in the complex conjugate one. We give the equivalent Langevin formulation, whose main ingredient is the color charge density linked to a projectile parton (a Wilson line).

  8. UNE COLORATION SIMPLE ET RAPIDE DU FROTTIS DU SPERME

    Institute of Scientific and Technical Information of China (English)

    杨建华; 朱继业

    2003-01-01

    Objective To introduce a rapid simple staining method for sperm morphology.MethodsLiquified semen was on the glass, fixed by methanol, treated with phosphonic acid buffer, stained by A,B staining solution separately, and rinsed by running water.ResultsAfter staining,the whole spermatozoid was very clear. The cephalic zone of spermatozoid head, acrosome area, was colored pink; its caudal zone colored violet red or violet blue. The body and tail of spermatozoid colored pink or light blue. Normal and abnormal morphology of spermatozoid could be differentiated easily. The sloughed spermatogenic cells and white blood cells could be differentiated also.ConclusionThis rapid staining method of semen smear can produce the same effect of other usual staining method , but the staining time is shorter and the procedure is simpler.

  9. Color-flow Doppler sonography in Graves disease: "thyroid inferno".

    Science.gov (United States)

    Ralls, P W; Mayekawa, D S; Lee, K P; Colletti, P M; Radin, D R; Boswell, W D; Halls, J M

    1988-04-01

    Graves disease is a common diffuse abnormality of the thyroid gland usually characterized by thyrotoxicosis. We performed color-flow Doppler sonography in 16 patients with Graves disease and compared the results with those in 15 normal volunteers and 14 patients with other thyroid diseases (eight with multinodular goiter, four with focal masses, and two with papillary thyroid carcinoma). All 16 Graves disease patients exhibited a pulsatile pattern we call "thyroid inferno." This pattern consists of multiple small areas of intrathyroidal flow seen diffusely throughout the gland in both systole and diastole. In systole, both high-velocity flow (color coded white) and lower velocity flow (color coded red and blue) were noted. In diastole, fewer areas of flow and lower velocity flow were noted. Patients with Graves disease also exhibited color flow around the periphery of the gland. The inferno pattern did not occur in normal subjects or in patients with other thyroid diseases. On occasion, focal areas of intrathyroidal flow were detected in patients with multinodular goiter and focal thyroid masses. High-resolution gray-scale images did not show the small vascular channels from which the flow signal originated. Color-flow Doppler sonography shows promise as a cost-effective, noninvasive technique for diagnosing Graves disease.

  10. Medium-induced color flow softens hadronization

    CERN Document Server

    Beraudo, A; Wiedemann, U A

    2012-01-01

    Medium-induced parton energy loss, resulting from gluon exchanges between the QCD matter and partonic projectiles, is expected to underly the strong suppression of jets and high-$p_T$ hadron spectra observed in ultra-relativistic heavy ion collisions. Here, we present the first color-differential calculation of parton energy loss. We find that color exchange between medium and projectile enhances the invariant mass of energetic color singlet clusters in the parton shower by a parametrically large factor proportional to the square root of the projectile energy. This effect is seen in more than half of the most energetic color-singlet fragments of medium-modified parton branchings. Applying a standard cluster hadronization model, we find that it leads to a characteristic additional softening of hadronic spectra. A fair description of the nuclear modification factor measured at the LHC may then be obtained for relatively low momentum transfers from the medium.

  11. Plane wave fast color flow mode imaging

    DEFF Research Database (Denmark)

    Bolic, Ibrahim; Udesen, Jesper; Gran, Fredrik

    2006-01-01

    degrees and 75 degrees. Compared to the conventional ultrasound imaging the frame rate is similar to 30 - 60 times higher. The bias, B-est of the velocity profile estimate, based on 8 pulse-echo emissions, is between 3.3% and 6.1% for beam to flow angles between 45 degrees and 75 degrees, and the standard...... deviation, sigma(est) of the velocity profile estimate is around 2% for beam to flow angles between 45 degrees and 75 degrees relative to the peak velocity, when the flow angle is known in advance. A study is performed to investigate how different parameters influence the blood velocity estimation....... The results confirmed expectations for beam to flow angles between 45 degrees and 75 degrees. The parameter study shows that the PWM using Directional velocity estimation gives the best results using spatial sampling interval = 10A, and number of directional signals >= 6...

  12. Jet Dipolarity: Top Tagging with Color Flow

    Energy Technology Data Exchange (ETDEWEB)

    Hook, Anson; Jankowiak, Martin; /SLAC /Stanford U., Phys. Dept.; Wacker, Jay G.; /SLAC

    2011-08-12

    A new jet observable, dipolarity, is introduced that can distinguish whether a pair of subjets arises from a color singlet source. This observable is incorporated into the HEPTopTagger and is shown to improve discrimination between top jets and QCD jets for moderate to high p{sub T}. The impressive resolution of the ATLAS and CMS detectors means that a typical QCD jet at the LHC deposits energy in {Omicron}(10-100) calorimeter cells. Such fine-grained calorimetry allows for jets to be studied in much greater detail than previously, with sophisticated versions of current techniques making it possible to measure more than just the bulk properties of jets (e.g. event jet multiplicities or jet masses). One goal of the LHC is to employ these techniques to extend the amount of information available from each jet, allowing for a broader probe of the properties of QCD. The past several years have seen significant progress in developing such jet substructure techniques. A number of general purpose tools have been developed, including: (i) top-tagging algorithms designed for use at both lower and higher p{sub T} as well as (ii) jet grooming techniques such as filtering, pruning, and trimming, which are designed to improve jet mass resolution. Jet substructure techniques have also been studied in the context of specific particle searches, where they have been shown to substantially extend the reach of traditional search techniques in a wide variety of scenarios, including for example boosted Higgses, neutral spin-one resonances, searches for supersymmetry, and many others. Despite these many successes, however, there is every reason to expect that there remains room for refinement of jet substructure techniques.

  13. Elliptic Flow from Nonequilibrium Color Glass Condensate Initial Conditions

    CERN Document Server

    Ruggieri, M; Plumari, S; Greco, V

    2013-01-01

    A current goal of relativistic heavy ion collisions experiments is the search for a Color Glass Condensate as the limiting state of QCD matter at very high density. In viscous hydrodynamics simulations, a standard Glauber initial condition leads to estimate $4\\pi \\eta/s \\sim 1$, while a Color Glass Condensate modeling leads to at least a factor of 2 larger $\\eta/s$. Within a kinetic theory approach based on a relativistic Boltzmann-like transport simulation, we point out that the out-of-equilibrium initial distribution proper of a Color Glass Condensate reduces the efficiency in building-up the elliptic flow. Our main result at RHIC energy is that the available data on $v_2$ are in agreement with a $4\\pi \\eta/s \\sim 1$ also for Color Glass Condensate initial conditions, opening the possibility to describe self-consistently also higher order flow, otherwise significantly underestimated, and to pursue further the search for signatures of the Color Glass Condensate.

  14. Clutter filter design for ultrasound color flow imaging.

    Science.gov (United States)

    Bjaerum, Steinar; Torp, Hans; Kristoffersen, Kjell

    2002-02-01

    For ultrasound color flow images with high quality, it is important to suppress the clutter signals originating from stationary and slowly moving tissue sufficiently. Without sufficient clutter rejection, low velocity blood flow cannot be measured, and estimates of higher velocities will have a large bias. The small number of samples available (8 to 16) makes clutter filtering in color flow imaging a challenging problem. In this paper, we review and analyze three classes of filters: finite impulse response (FIR), infinite impulse response (IIR), and regression filters. The quality of the filters was assessed based on the frequency response, as well as on the bias and variance of a mean blood velocity estimator using an autocorrelation technique. For FIR filters, the frequency response was improved by allowing a non-linear phase response. By estimating the mean blood flow velocity from two vectors filtered in the forward and backward direction, respectively, the standard deviation was significantly lower with a minimum phase filter than with a linear phase filter. For IIR filters applied to short signals, the transient part of the output signal is important. We analyzed zero, step, and projection initialization, and found that projection initialization gave the best filters. For regression filters, polynomial basis functions provide effective clutter suppression. The best filters from each of the three classes gave comparable bias and variance of the mean blood velocity estimates. However, polynomial regression filters and projection-initialized IIR filters had a slightly better frequency response than could be obtained with FIR filters.

  15. Color aids late but not early stages of rapid natural scene recognition.

    Science.gov (United States)

    Yao, Angela Y J; Einhäuser, Wolfgang

    2008-12-22

    Color has an unresolved role in natural scene recognition. Whereas rapid serial visual presentation paradigms typically find no advantage for colored over grayscale scenes, color seems to play a decisive role for recognition memory. The distinction between detection and memorization has not been addressed directly in one paradigm. Here we asked ten observers to detect animals in 2-s 20 Hz sequences. Each sequence consisted of two 1-s segments, one of grayscale images and one of colored; each segment contained one or no target, totaling zero, one, or two targets per sequence. In one-target sequences, hit rates were virtually the same for targets appearing in the first or second segment, as well as for grayscale and colored targets, though observers were more confident about detecting colored targets. In two-target sequences, observers preferentially reported the second of two identical targets, in comparison to categorically related (same-species animals) or unrelated (different-species animals) targets. Observers also showed a strong preference for reporting colored targets, though only when targets were of different species. Our findings suggest that color has little effect on detection, but is used in later stages of processing. We may speculate that color ensures preferential access to or retrieval from memory when distinct items must be rapidly remembered.

  16. Adaptive Spectral Estimation Methods in Color Flow Imaging.

    Science.gov (United States)

    Karabiyik, Yucel; Ekroll, Ingvild Kinn; Eik-Nes, Sturla H; Avdal, Jorgen; Lovstakken, Lasse

    2016-11-01

    Clutter rejection for color flow imaging (CFI) remains a challenge due to either a limited amount of temporal samples available or nonstationary tissue clutter. This is particularly the case for interleaved CFI and B-mode acquisitions. Low velocity blood signal is attenuated along with the clutter due to the long transition band of the available clutter filters, causing regions of biased mean velocity estimates or signal dropouts. This paper investigates how adaptive spectral estimation methods, Capon and blood iterative adaptive approach (BIAA), can be used to estimate the mean velocity in CFI without prior clutter filtering. The approach is based on confining the clutter signal in a narrow spectral region around the zero Doppler frequency while keeping the spectral side lobes below the blood signal level, allowing for the clutter signal to be removed by thresholding in the frequency domain. The proposed methods are evaluated using computer simulations, flow phantom experiments, and in vivo recordings from the common carotid and jugular vein of healthy volunteers. Capon and BIAA methods could estimate low blood velocities, which are normally attenuated by polynomial regression filters, and may potentially give better estimation of mean velocities for CFI at a higher computational cost. The Capon method decreased the bias by 81% in the transition band of the used polynomial regression filter for small packet size ( N=8 ) and low SNR (5 dB). Flow phantom and in vivo results demonstrate that the Capon method can provide color flow images and flow profiles with lower variance and bias especially in the regions close to the artery walls.

  17. Two-color, double-slit in vivo flow cytometer.

    Science.gov (United States)

    Novak, J; Puoris'haag, M

    2007-10-15

    The in vivo flow cytometer enables the real-time detection and quantification of fluorescent cells circulating within a live animal without the need for incisions or extraction of blood. It has been used in demonstrating flow velocity disparities in biological flows, and in the investigation of the circulation kinetics of various types of cells. However, a shortcoming of this in vivo flow cytometer is that it provides only one excitation slit at one wavelength, resulting in several performance limitations. Therefore, a second in vivo flow cytometer that provides two different laser wavelengths, 473 and 633 nm, and one or two excitation slits has been designed and built. Thus far, the two-color system has been used to acquire circulation kinetics data of two different cell populations each labeled with a different marker, one cell population labeled with two different markers, and one cell population expressing the green-fluorescent protein gene. In addition, accurate arterial red blood cell velocities within a mouse have been determined using the cytometer.

  18. Patterns, Instabilities, Colors, and Flows in Vertical Foam Films

    Science.gov (United States)

    Yilixiati, Subinuer; Wojcik, Ewelina; Zhang, Yiran; Pearsall, Collin; Sharma, Vivek

    2015-03-01

    Foams find use in many applications in daily life, industry and biology. Examples include beverages, firefighting foam, cosmetics, foams for oil recovery and foams formed by pollutants. Foams are collection of bubbles separated by thin liquid films that are stabilized against drainage by the presence of surfactant molecules. Drainage kinetics and stability of the foam are strongly influenced by surfactant type, addition of particles, proteins and polymers. In this study, we utilize the thin film interference colors as markers for identifying patterns, instabilities and flows within vertical foam films. We experimentally study the emergence of thickness fluctuations near the borders and within thinning films, and study how buoyancy, capillarity and gravity driven instabilities and flows, are affected by variation in bulk and interfacial physicochemical properties dependent on the choice of constituents.

  19. Color-Phase Analysis for Sinusoidal Structured Light in Rapid Range Imaging

    CERN Document Server

    Je, Changsoo; Park, Rae-Hong

    2015-01-01

    Active range sensing using structured-light is the most accurate and reliable method for obtaining 3D information. However, most of the work has been limited to range sensing of static objects, and range sensing of dynamic (moving or deforming) objects has been investigated recently only by a few researchers. Sinusoidal structured-light is one of the well-known optical methods for 3D measurement. In this paper, we present a novel method for rapid high-resolution range imaging using color sinusoidal pattern. We consider the real-world problem of nonlinearity and color-band crosstalk in the color light projector and color camera, and present methods for accurate recovery of color-phase. For high-resolution ranging, we use high-frequency patterns and describe new unwrapping algorithms for reliable range recovery. The experimental results demonstrate the effectiveness of our methods.

  20. A Reconstruction Method of Blood Flow Velocity in Left Ventricle Using Color Flow Ultrasound

    Directory of Open Access Journals (Sweden)

    Jaeseong Jang

    2015-01-01

    Full Text Available Vortex flow imaging is a relatively new medical imaging method for the dynamic visualization of intracardiac blood flow, a potentially useful index of cardiac dysfunction. A reconstruction method is proposed here to quantify the distribution of blood flow velocity fields inside the left ventricle from color flow images compiled from ultrasound measurements. In this paper, a 2D incompressible Navier-Stokes equation with a mass source term is proposed to utilize the measurable color flow ultrasound data in a plane along with the moving boundary condition. The proposed model reflects out-of-plane blood flows on the imaging plane through the mass source term. The boundary conditions to solve the system of equations are derived from the dimensions of the ventricle extracted from 2D echocardiography data. The performance of the proposed method is evaluated numerically using synthetic flow data acquired from simulating left ventricle flows. The numerical simulations show the feasibility and potential usefulness of the proposed method of reconstructing the intracardiac flow fields. Of particular note is the finding that the mass source term in the proposed model improves the reconstruction performance.

  1. Sonographic evaluation of thyroiditis with color flow study.

    Science.gov (United States)

    Sultana, N; Rima, S; Rahman, S; Azad, S A; Karim, M E; Shawkat, S; Ahsan, M; Kamal, M M; Begum, M

    2014-01-01

    This cross sectional study was carried out in the Department of Radiology and Imaging, Bangabandhu Sheikh Mujib Medical University, Bangladesh in collaboration with the Department of Endocrinology and Department of Histopathology of the same hospital during the period of March 2007 to February 2008 to determine efficacy of ultrasonogram in the evaluation of thyroiditis and to compare its results with color flow Doppler study. For this purpose, a total of 50 patients having clinical suspicion of thyroiditis were enrolled in this study. Ultrasound and color Doppler were done in all these patients. Then all patients underwent for FNAC in the Histopathology department. Correlation between sonographic diagnosis and histopathological diagnosis were observed. Out of these 50 patients 10(20%) were male and 40 (80%) were female with age ranging from 12 to 50 years, highest between 21 to 30 years. The mean age of the patients was 30.42±9.57 years. On unltrasonographic findings of thyroid gland 42.0% patients had regular and 58.0% had irregular margin. Seventy percent had fibrosis, 14.0% had feature of necrosis, 48.0% had lymphadenopathy. Out of all patients 6.0% had normal echogenic feature, 16.0% had increased and 78.0% decreased echogeneic feature. Twelve percent (12.0%) patients had homogeneous and 88.0% had heterogeneous pattern of echogenecity. Thirty eight percent (38%) patients had focal nodules. Sixty percent (60.0%) patients had focal swelling and 40.0% had diffuse swelling. On color flow Doppler 28.0% had normal, 38.0% had increased and 34.0% decreased vascular flow pattern. USG reports revealed that 48.0% had thyromegaly, 36.0% had thyroid nodule, 10.0% had multinodular goiter and 6.0% had thyroid abscess. FNAC diagnosis revealed that 34.0% patients had Hashimoto's thyroiditis, 24.0% had lymphocytic thyroiditis, 18.0% had granulomatous thyroiditis, 6.0% had abscess, 8.0% had goitre and 10.0% nonspecific. USG and CFD are recommended modalities for the diagnosis of

  2. The rapid generation of isothiocyanates in flow

    Directory of Open Access Journals (Sweden)

    Marcus Baumann

    2013-08-01

    Full Text Available Isothiocyanates are versatile starting materials for a wide range of chemical reactions. However, their high nucleophilic susceptibility means they are best prepared and used immediately. We report here on a flow platform for the fast and efficient formation of isothiocyanates by the direct conversion of easily prepared chloroximes. To expedite this chemistry a flow insert cartridge containing two immobilised reagents is used to affect the chemical transformation which typically eliminates the requirements for any conventional work-up or purification of the reaction stream.

  3. Whiteness process of tile ceramics: using a synthetic flow as a modifier agent of color firing

    Science.gov (United States)

    dos Santos, G. R.; Pereira, M. C.; Olzon-Dionysio, M.; de Souza, S. D.; Morelli, M. R.

    2014-01-01

    Synthetic flow is proposed as a modifier agent of color firing in tile ceramic mass during the sinterization process, turning the red color firing into whiteness. Therefore, the 57Fe Mössbauer spectroscopy was used to understand how the interaction of the iron element in the mechanism of color firing mass occurs in this system. The results suggest that the change of color firing can be alternatively due to two main factors: (i) diluting the hematite content in the sample because of the use of synthetic flow and (ii) part of the hematite is converted in other uncolored crystal structures, which makes the final color firing lighter.

  4. The contribution of medium-modified color flow to jet quenching

    CERN Document Server

    Beraudo, A; Wiedemann, U A

    2012-01-01

    Multiple interactions between parton showers and the surrounding QCD matter are expected to underlie the strong medium-modifications of jet observables in ultra-relativistic heavy ion collisions at RHIC and at the LHC. Here, we note that such jet-medium interactions alter generically and characteristically the color correlations in the parton shower. We characterize these effects in a color-differential calculation of the medium-induced gluon radiation spectrum to first and second order in opacity. By interfacing simple branching histories of medium-modified color flow with the Lund hadronization model, we analyze how the medium modification of color correlations can affect the distribution of hadronic fragments in jets. Importantly, we observe that jet-medium interactions give rise to the medium-induced color decoherence of gluons from the parton shower. Since hadronization respects color flow and since each color singlet in a parton shower is hadronized separately, this medium-induced color decoherence leav...

  5. Genome scan for cognitive trait loci of dyslexia: rapid naming and rapid switching of letters, numbers, and colors

    Science.gov (United States)

    Rubenstein, Kevin; Raskind, Wendy H.; Berninger, Virginia W.; Matsushita, Mark M.; Wijsman, Ellen M.

    2014-01-01

    Dyslexia, or specific reading disability, is a common developmental disorder that affects 5–12% of school-aged children. Dyslexia and its component phenotypes, assessed categorically or quantitatively, have complex genetic bases. The ability to rapidly name letters, numbers, and colors from rows presented visually correlates strongly with reading in multiple languages and is a valid predictor of reading and spelling impairment. Performance on measures of rapid naming and switching, RAN and RAS, is stable throughout elementary school years, with slowed performance persisting in adults who still manifest dyslexia. Targeted analyses of dyslexia candidate regions have included RAN measures, but only one other genome-wide linkage study has been reported. As part of a broad effort to identify genetic contributors to dyslexia, we performed combined oligogenic segregation and linkage analyses of measures of RAN and RAS in a family-based cohort ascertained through probands with dyslexia. We obtained strong evidence for linkage of RAN letters to the DYX3 locus on chromosome 2p and RAN colors to chromosome 10q, but were unable to confirm the chromosome 6p21 linkage detected for a composite measure of RAN colors and objects in the previous genome-wide study. PMID:24807833

  6. Genome scan for cognitive trait loci of dyslexia: Rapid naming and rapid switching of letters, numbers, and colors.

    Science.gov (United States)

    Rubenstein, Kevin B; Raskind, Wendy H; Berninger, Virginia W; Matsushita, Mark M; Wijsman, Ellen M

    2014-06-01

    Dyslexia, or specific reading disability, is a common developmental disorder that affects 5-12% of school-aged children. Dyslexia and its component phenotypes, assessed categorically or quantitatively, have complex genetic bases. The ability to rapidly name letters, numbers, and colors from rows presented visually correlates strongly with reading in multiple languages and is a valid predictor of reading and spelling impairment. Performance on measures of rapid naming and switching, RAN and RAS, is stable throughout elementary school years, with slowed performance persisting in adults who still manifest dyslexia. Targeted analyses of dyslexia candidate regions have included RAN measures, but only one other genome-wide linkage study has been reported. As part of a broad effort to identify genetic contributors to dyslexia, we performed combined oligogenic segregation and linkage analyses of measures of RAN and RAS in a family-based cohort ascertained through probands with dyslexia. We obtained strong evidence for linkage of RAN letters to the DYX3 locus on chromosome 2p and RAN colors to chromosome 10q, but were unable to confirm the chromosome 6p21 linkage detected for a composite measure of RAN colors and objects in the previous genome-wide study. © 2014 Wiley Periodicals, Inc.

  7. Rapid expulsion of microswimmers by a vortical flow.

    Science.gov (United States)

    Sokolov, Andrey; Aranson, Igor S

    2016-03-23

    Interactions of microswimmers with their fluid environment are exceptionally complex. Macroscopic shear flow alters swimming trajectories in a highly nontrivial way and results in dramatic reduction of viscosity and heterogeneous bacterial distributions. Here we report on experimental and theoretical studies of rapid expulsion of microswimmers, such as motile bacteria, by a vortical flow created by a rotating microparticle. We observe a formation of a macroscopic depletion area in a high-shear region, in the vicinity of a microparticle. The rapid migration of bacteria from the shear-rich area is caused by a vortical structure of the flow rather than intrinsic random fluctuations of bacteria orientations, in stark contrast to planar shear flow. Our mathematical model reveals that expulsion is a combined effect of motility and alignment by a vortical flow. Our findings offer a novel approach for manipulation of motile microorganisms and shed light on bacteria-flow interactions.

  8. Rapid expulsion of microswimmers by a vortical flow

    Science.gov (United States)

    Sokolov, Andrey; Aranson, Igor S.

    2016-01-01

    Interactions of microswimmers with their fluid environment are exceptionally complex. Macroscopic shear flow alters swimming trajectories in a highly nontrivial way and results in dramatic reduction of viscosity and heterogeneous bacterial distributions. Here we report on experimental and theoretical studies of rapid expulsion of microswimmers, such as motile bacteria, by a vortical flow created by a rotating microparticle. We observe a formation of a macroscopic depletion area in a high-shear region, in the vicinity of a microparticle. The rapid migration of bacteria from the shear-rich area is caused by a vortical structure of the flow rather than intrinsic random fluctuations of bacteria orientations, in stark contrast to planar shear flow. Our mathematical model reveals that expulsion is a combined effect of motility and alignment by a vortical flow. Our findings offer a novel approach for manipulation of motile microorganisms and shed light on bacteria–flow interactions. PMID:27005581

  9. A bioinspired color-changing polystyrene microarray as a rapid qualitative sensor for methanol and ethanol

    Energy Technology Data Exchange (ETDEWEB)

    Kuo, Wen-Kai, E-mail: wkkuo@nfu.edu.tw [Graduate Institute of Electro-Optical and Materials Science, National Formosa University, 64 Wenhua Road, Huwei, Yunlin 63208, Taiwan (China); Weng, Hsueh-Ping, E-mail: sherry.weng7949@gmail.com [Graduate Institute of Electro-Optical and Materials Science, National Formosa University, 64 Wenhua Road, Huwei, Yunlin 63208, Taiwan (China); Hsu, Jyun-Jheng, E-mail: k88520x@gmail.com [Graduate Institute of Electro-Optical and Materials Science, National Formosa University, 64 Wenhua Road, Huwei, Yunlin 63208, Taiwan (China); Yu, Hsin Her, E-mail: hhyu@nfu.edu.tw [Department of Biotechnology, National Formosa University, 64 Wenhua Road, Huwei, Yunlin 63208, Taiwan (China)

    2016-04-15

    Polystyrene (PS) microspheres were synthesized by emulsifier-free emulsion polymerization and arranged in an array of closely packed, opal-like photonic crystals by slow self-assembly through dip-coating. This periodic array of PS microspheres was then employed as a rapid qualitative sensor for methanol and ethanol. Both solvents could be detected rapidly based on the routes of their reflection coordinates in the chromaticity diagram or directly by the naked eye on the basis of the change in color within 1 min once a solvent sample had been placed on the PS photochromic sensor. This opal-like PS sensor can thus not only be employed as a rapid sensor for methanol and ethanol but can also be used as a powerful tool for the fast screening of illicit drugs and toxic chemicals during forensic investigations. - Highlights: • Opal-like array of polystyrene (PS) microspheres is synthesized by self-assembly. • This periodic PS array is used as a rapid sensor for methanol and ethanol. • Solvents are detected by routes of reflection coordinates in chromaticity diagram. • They are also detected directly by naked eye based on change in color of sensor. • The color change is irreversible for methanol but reversible for ethanol.

  10. A reconstruction method of intra-ventricular blood flow using color flow ultrasound: a simulation study

    Science.gov (United States)

    Jang, Jaeseong; Ahn, Chi Young; Jeon, Kiwan; Choi, Jung-il; Lee, Changhoon; Seo, Jin Keun

    2015-03-01

    A reconstruction method is proposed here to quantify the distribution of blood flow velocity fields inside the left ventricle from color Doppler echocardiography measurement. From 3D incompressible Navier- Stokes equation, a 2D incompressible Navier-Stokes equation with a mass source term is derived to utilize the measurable color flow ultrasound data in a plane along with the moving boundary condition. The proposed model reflects out-of-plane blood flows on the imaging plane through the mass source term. For demonstrating a feasibility of the proposed method, we have performed numerical simulations of the forward problem and numerical analysis of the reconstruction method. First, we construct a 3D moving LV region having a specific stroke volume. To obtain synthetic intra-ventricular flows, we performed a numerical simulation of the forward problem of Navier-Stokes equation inside the 3D moving LV, computed 3D intra-ventricular velocity fields as a solution of the forward problem, projected the 3D velocity fields on the imaging plane and took the inner product of the 2D velocity fields on the imaging plane and scanline directional velocity fields for synthetic scanline directional projected velocity at each position. The proposed method utilized the 2D synthetic projected velocity data for reconstructing LV blood flow. By computing the difference between synthetic flow and reconstructed flow fields, we obtained the averaged point-wise errors of 0.06 m/s and 0.02 m/s for u- and v-components, respectively.

  11. Two and three-color fluorescence flow cytometric analysis of immunoidentified viable bacteria.

    Science.gov (United States)

    Barbesti, S; Citterio, S; Labra, M; Baroni, M D; Neri, M G; Sgorbati, S

    2000-07-01

    Traditional culture methods well established in the past and still in use are not able to detect the environmental microorganisms that exist in a viable but not culturable state. A number of different fluorescence-based assays have been developed over the past decade to detect and identify viable bacteria in the environment. We have developed a simple and rapid method for measuring the number and viability of immunolabeled bacteria by means of a two/three color fluorescence flow cytometric analysis. After washing, cultured bacteria in suspension were labeled with a rabbit polyclonal antibody recognizing the wall lipopolysaccharide complex. A secondary biotinylated anti-rabbit polyclonal antibody was added allowing the cells to be labeled with the streptavidin R-phycoerythrin-Cyanine 5 (RPE-Cy5) fluorochrome. Before flow cytometric analysis, bacterial suspensions were stained with SYBR Green I and propidium iodide which stain all of the cells and the non viable ones, respectively. With the appropriate filter sets of both Bryte-HS (Bio-Rad, Hercules, CA) and FACScan (Becton Dickinson, San Jose, CA) flow cytometers, the measurement of separated green (SYBR Green I), orange-red (propidium iodide), and far red (RPE-Cy5) fluorescence was possible, allowing the enumeration of viable immunodetected bacteria. The entire protocol is completed in less than 3 h, offering numerous possibilities for rapid and precise analyses in sanitary, industrial, and environmental microbiology. Copyright 2000 Wiley-Liss, Inc.

  12. Power and color Doppler ultrasound settings for inflammatory flow

    DEFF Research Database (Denmark)

    Torp-Pedersen, Søren; Christensen, Robin; Szkudlarek, Marcin

    2015-01-01

    OBJECTIVE: To determine how settings for power and color Doppler ultrasound sensitivity vary on different high- and intermediate-range ultrasound machines and to evaluate the impact of these changes on Doppler scoring of inflamed joints. METHODS: Six different types of ultrasound machines were used....... On each machine, the factory setting for superficial musculoskeletal scanning was used unchanged for both color and power Doppler modalities. The settings were then adjusted for increased Doppler sensitivity, and these settings were designated study settings. Eleven patients with rheumatoid arthritis (RA......) with wrist involvement were scanned on the 6 machines, each with 4 settings, generating 264 Doppler images for scoring and color quantification. Doppler sensitivity was measured with a quantitative assessment of Doppler activity: color fraction. Higher color fraction indicated higher sensitivity. RESULTS...

  13. In vivo color flow mapping using synthetic aperture dual stage beamforming

    DEFF Research Database (Denmark)

    Li, Ye; Hemmsen, Martin Christian; Nielsen, Michael Bachmann;

    2012-01-01

    An in vivo investigation of synthetic aperture flow imaging using a dual stage beamformer is presented in this paper. In the previous work, simulations and Doppler flow phantom experiments showed promising results, which indicated the methods capability of producing fast color flow mapping...... deviation is 14.3% and relative bias is 6.4% for the phantom measurements. The blood flow in a common carotid artery of a 35-year-old healthy male is scanned by a medical doctor (PMH). The in vivo data is processed off-line. Fast synthetic aperture color flow mapping with frame rate of 85 Hz is produced...

  14. Rapid integumental color changes due to novel iridophores in the chameleon sand tilefish Hoplolatilus chlupatyi.

    Science.gov (United States)

    Goda, Makoto

    2017-05-01

    The wavelength of the light reflected from iridophores depends on the thickness and the spacing of intracellular reflecting platelets. Here, we show that the rapid color change from blue to red of the chameleon sand tilefish Hoplolatilus chlupatyi is mediated by adrenergic stimulation of a novel type of iridophore in which reflecting platelets are concentrated selectively in the periphery of the cell, near the plasma membrane. The color changes are not only observed in vivo but also in pigment cells of isolated scales which respond to increases in K(+) ion concentrations in 0.5 s and to addition of norepinephrine within 1 s. The norepinephrine effect can be blocked by addition of the alpha-adrenergic antagonist phentolamine. The results suggest that adrenergic stimulation leads to changes in reflecting platelet organization in Hoplolatilus chlupatyi iridophores and represents the major mediator of the rapid color change in this fish in vivo. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  15. Experimental verification of color flow imaging based on wideband Doppler method.

    Science.gov (United States)

    Tanaka, Naohiko

    2014-01-01

    The purpose of this study is to eliminate the aliasing in color flow imaging. The wideband Doppler method is applied to generate a color flow image, and the validity of the method is experimentally confirmed. The single beam experiment is carried out to confirm the velocity estimation based on the wideband Doppler method. The echo data for the conventional pulsed Doppler method and the wideband Doppler method are obtained using a flow model, and the estimated velocity for each method is compared. The color flow images for each method are also generated using several types of flow model. The generated images are compared, and the characteristics of the imaging based on the wideband Doppler method are discussed. The high velocity beyond the Nyquist limit is successfully estimated by the wideband Doppler method, and the availability in low velocity estimation is also confirmed. The aliasing in color flow images is eliminated, and the generated images show the significance of the elimination of the aliasing in the flow imaging. The aliasing in color flow imaging can be eliminated by the wideband Doppler method. This technique is useful for the exact understanding of blood flow dynamics.

  16. Color-infrared composite of Landsat data for the Death Valley regional flow system

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — The raster-based, color-infrared composite was derived from Landsat Thematic Mapper imagery data acquired during June 1992 for the Death Valley regional flow system....

  17. Influence of auroral streamers on rapid evolution of SAPS flows

    Science.gov (United States)

    Gallardo-Lacourt, B.; Nishimura, T.; Lyons, L. R.; Ruohoniemi, J. M.; Donovan, E.; Angelopoulos, V.; Nishitani, N.

    2015-12-01

    An important manifestation of plasma transport in the ionosphere is Subauroral Polarization Streams or SAPS, which are strong westward flow lying just equatorward of the electron auroral oval and thus of enhanced ionospheric conductivities of the auroral oval. While SAPS are known to intensify due to substorm injections, recent studies showed that large variability of SAPS flow can occur well after substorm onset and even during non-substorm times. These SAPS enhancements have been suggested to occur in association with auroral streamers that propagate equatorward, a suggestion that would indicate that plasma sheet fast flows propagate into the inner magnetosphere and increase subauroral flows. We present auroral images from the THEMIS ground-based all-sky-imager array and 2-d line-of-sight flow observations from the SuperDARN radars that share fields of view with the imagers to investigate systematically the association between SAPS and auroral streamers. We surveyed events from December 2007 to April 2013 for which high or mid-latitude SuperDARN radars were available to measure the SAPS flows, and identified 60 events. For streamers observed near the equatorward boundary of the auroral oval, we find westward flow enhancements of ~200 m/s slightly equatorward of the streamers. A preliminary survey suggests that >90% of the streamers that reach close to the equatorward boundary lead to westward flow enhancements. We also characterize the SAPS flow channel width and timing relative to streamers reaching radar echo meridians. The strong influence of auroral streamers on rapid SAPS flow evolution suggests that transient fast earthward plasma sheet flows can lead to westward SAPS flow enhancements in the subauroral region, and that such enhancements are far more common than only during substorms because of the frequent occurrences of streamers under various geomagnetic conditions.

  18. Rapid sympatry explains greater color pattern divergence in high latitude birds.

    Science.gov (United States)

    Martin, Paul R; Montgomerie, Robert; Lougheed, Stephen C

    2010-02-01

    Latitudinal variation in patterns of evolution has fascinated biologists for over a century, but our understanding of latitudinal differences in evolutionary processes-such as selection and drift-remains limited. Here, we test for, and find, accelerated evolution of color patterns in bird taxa that breed at higher latitudes compared with those breeding in the tropics, analyzing data from seven diverse avian families. Most important, we show that the extent of overlap of species' breeding ranges (degree of sympatry) explains the elevated rate of color pattern evolution at higher latitudes. We suggest that the dynamic shifts in breeding ranges that accompanied climatic changes during the last 3 million years (Milankovitch Oscillations) resulted in more rapid and more frequent secondary contact at high latitudes. We argue that sympatry among diverging clades causes greater divergence of color traits in birds at higher latitudes through sexual, social, or ecological character displacement that accelerate rates of evolution, and through the selective elimination of weakly differentiated lineages that hybridize and fuse in sympatry (differential fusion).

  19. Generating QCD amplitudes in the color-flow basis with MadGraph

    CERN Document Server

    Hagiwara, Kaoru

    2010-01-01

    We propose to make use of the off-shell recursive relations with the color-flow decomposition in the calculation of QCD amplitudes on MadGraph. We introduce colored quarks and their interactions with nine gluons in the color-flow basis plus an Abelian gluon on MadGraph, such that it generates helicity amplitudes in the color-flow basis with off-shell recursive formulae for multi-gluon sub-amplitudes. We demonstrate calculations of up to 5-jet processes such as $gg\\rightarrow 5g$, $u\\bar{u}\\rightarrow 5g$ and $uu\\rightarrow uuggg$. Although our demonstration is limited, it paves the way to evaluate amplitudes with more quark lines and gluons with Madgraph.

  20. Color me healthy: food diversity in school community gardens in two rapidly urbanising Australian cities.

    Science.gov (United States)

    Guitart, Daniela A; Pickering, Catherine M; Byrne, Jason A

    2014-03-01

    Community garden research has focused on social aspects of gardens, neglecting systematic analysis of what food is grown. Yet agrodiversity within community gardens may provide health benefits. Diverse fruit and vegetables provide nutritional benefits, including vitamins, minerals and phytochemicals. This paper reports research that investigated the agro-biodiversity of school-based community gardens in Brisbane and Gold Coast cities, Australia. Common motivations for establishing these gardens were education, health and environmental sustainability. The 23 gardens assessed contained 234 food plants, ranging from 7 to 132 plant types per garden. This included 142 fruits and vegetables. The nutritional diversity of fruits and vegetable plants was examined through a color classification system. All gardens grew fruits and vegetables from at least four food color groups, and 75% of the gardens grew plants from all seven color groups. As places with high agrodiversity, and related nutritional diversity, some school community gardens can provide children with exposure to a healthy range of fruit and vegetables, with potential flow-on health benefits.

  1. Laparoscopic splenectomy: color Doppler flow imaging for preoperative evaluation

    Institute of Scientific and Technical Information of China (English)

    XU Wei-li; LI Suo-lin; WANG Yan; SHI Bao-jun; LI Meng; LI Ying-chao; ZHONG Zhi-yong; LI Zhen-dong

    2009-01-01

    Background Laparoscopic splenectomy (LS) is currently the standard approach for resection of a normal-sized spleen.However, this method becomes technical challenge in cases of splenomegaly due to intraoperative hemorrhage. A complete understanding of the splenic vessel anatomy is important to facilitate the difficult laparoscopic procedure. In this retrospective study, we examined the role of color Doppler flow imaging (CDFI) in splenic vessel anatomy and evaluated its value for LS.Methods Forty-eight patients who underwent splenectomy for various hematologic and autoimmune disorders from May 2004 to December 2007 were enrolled in this study. Twenty-three patients underwent preoperative CDFI examination that included examination of the anatomic type of splenic pedicle, the adjacent relationship between the splenic vessel and pancreas, and spleen size (CDFI group). In the remaining 25 patients, ultrasonic inspections of the splenic vessel were not performed (non-CDFI group). Laparoscopic splenectomies in the CDFI group were performed in accordance with the information provided by the preoperative CDFI in each patient. In the non-CDFI group, LS was performed according to the conventional method. In the CDFI group, the constituent ratios of the above-mentioned parameters by CDFI were compared with those recorded during LS using the chi square test. The effectiveness of the technique on surgery in both groups was compared with an independent sample Student's ttest.Results All laparoscopic splenectomies in both groups were performed successfully. However, 2 cases in the non-CDFI group were converted to LS with the assistance of micro-incision because the branches of the splenic vein were inadvertently torn. Two anatomic types of splenic pedicle and four different adjacent relationships between the splenic vessel and pancreas were detected by CDFI. About 80% of spleens fit the criteria of megalosplenia. There were no statistically significant differences between the

  2. Accuracy of flow convergence estimates of mitral regurgitant flow rates obtained by use of multiple color flow Doppler M-mode aliasing boundaries: an experimental animal study.

    Science.gov (United States)

    Zhang, J; Jones, M; Shandas, R; Valdes-Cruz, L M; Murillo, A; Yamada, I; Kang, S U; Weintraub, R G; Shiota, T; Sahn, D J

    1993-02-01

    The proximal flow convergence method of multiplying color Doppler aliasing velocity by flow convergence surface area has yielded a new means of quantifying flow rate by noninvasively derived measurements. Unlike previous methods of visualizing the turbulent jet of mitral regurgitation on color flow Doppler mapping, flow convergence methods are less influenced by machine factors because of the systematic structure of the laminar flow convergence region. However, recent studies have demonstrated that the flow rate calculated from the first aliasing boundary of color flow Doppler imaging is dependent on orifice size, flow rate, aliasing velocity and therefore on the distance from the orifice chosen for measurement. In this study we calculated the regurgitant flow rates acquired by use of multiple proximal aliasing boundaries on color Doppler M-mode traces and assessed the effect of distances of measurement and aliasing velocities on the calculated regurgitant flow rate. Six sheep with surgically induced mitral regurgitation were studied. The distances from the mitral valve leaflet M-mode line to the first, second, and third sequential aliasing boundaries on color Doppler M-mode traces were measured and converted to the regurgitant flow rates calculated by applying the hemispheric flow equation and averaging instantaneous flow rates throughout systole. The flow rates that were calculated from the first, second, and third aliasing boundaries correlated well with the actual regurgitant flow rates (r = 0.91 to 0.96). The mean percentage error from the actual flow rates were 151% for the first aliasing boundary, 7% for the second aliasing boundary, and -43% for the third aliasing boundary; and the association between aliasing velocities and calculated flow rates indicates an inverse relationship, which suggests that in this model, there were limited velocity-distance combinations that fit with a hemispheric assumption for flow convergence geometry. The second aliasing

  3. Multi-Frequency Encoding for Fast Color Flow or Quadroplex Imaging

    DEFF Research Database (Denmark)

    Oddershede, Niels; Gran, Fredrik; Jensen, Jørgen Arendt

    2008-01-01

    acquiring spectrogram data for triplex imaging. This paper proposes a method for decreasing the data acquisition time by simultaneously sampling multiple lines for color flow maps, using narrow band signals with approximately disjoint spectral support. The signals are separated in the receiver by filters......Ultrasonic color flow maps are made by estimating the velocities line by line over the region of interest. For each velocity estimate, multiple repetitions are needed. This sets a limit on the frame rate, which becomes increasingly severe when imaging deeper lying structures or when simultaneously....... A mean standard deviation across the flow profile of 3.1, 2.5, and 2.1% of the peak velocity was found for bands at 5 MHz, 7 MHz, and 9 MHz, respectively. Alternatively, the method can be used for simultaneously sampling data for a color flow map and for multiple spectrograms using different spectral...

  4. Energy considerations in accelerating rapid shear granular flows

    Directory of Open Access Journals (Sweden)

    S. P. Pudasaini

    2009-05-01

    Full Text Available We present a complete expression for the total energy associated with a rapid frictional granular shear flow down an inclined surface. This expression reduces to the often used energy for a non-accelerating flow of an isotropic, ideal fluid in a horizontal channel, or to the energy for a vertically falling mass. We utilize thickness-averaged mass and momentum conservation laws written in a slope-defined coordinate system. Both the enhanced gravity and friction are taken into account in addition to the bulk motion and deformation. The total energy of the flow at a given spatial position and time is defined as the sum of four energy components: the kinetic energy, gravity, pressure and the friction energy. Total energy is conserved for stationary flow, but for non-stationary flow the non-conservative force induced by the free-surface gradient means that energy is not conserved. Simulations and experimental results are used to sketch the total energy of non-stationary flows. Comparison between the total energy and the sum of the kinetic and pressure energy shows that the contribution due to gravity acceleration and frictional resistance can be of the same order of magnitude, and that the geometric deformation plays an important role in the total energy budget of the cascading mass. Relative importance of the different constituents in the total energy expression is explored. We also introduce an extended Froude number that takes into account the apparent potential energy induced by gravity and pressure.

  5. Adaptive Channel-Tracking Method and Equalization for MC-CDMA Systems over Rapidly Fading Channel under Colored Noise

    Directory of Open Access Journals (Sweden)

    Chen Bor-Sen

    2010-01-01

    Full Text Available A recursive maximum-likelihood (RML algorithm for channel estimation under rapidly fading channel and colored noise in a multicarrier code-division multiple-access (MC-CDMA system is proposed in this paper. A moving-average model with exogenous input (MAX is given to describe the transmission channel and colored noise. Based on the pseudoregression method, the proposed RML algorithm can simultaneously estimate the parameters of channel and colored noise. Following the estimation results, these parameters can be used to enhance the minimum mean-square error (MMSE equalizer. Considering high-speed mobile stations, a one-step linear trend predictor is added to improve symbol detection. Simulation results indicate that the proposed RML estimator can track the channel more precisely than the conventional estimator. Meanwhile, the performance of the proposed enhanced MMSE equalizer is robust to the rapidly Rayleigh fading channel under colored noise in the MC-CDMA systems.

  6. Noninvasive color Doppler sonography of uterine blood flow throughout pregnancy in sheep and goats.

    Science.gov (United States)

    Elmetwally, M; Rohn, K; Meinecke-Tillmann, S

    2016-04-01

    In contrast to cattle or horses, uterine blood flow in small ruminants has been investigated predominantly after surgical intervention and chronic instrumentation. The objective of the present study was to investigate the clinical applicability of noninvasive color Doppler sonography to characterize blood flow in the maternal uterine artery of sheep, n = 11 (18 pregnancies) and goats, n = 11 (20 pregnancies). The following parameters were measured transrectally or transabdominally: blood flow volume, time-averaged maximum velocity (TAMV), resistance index (RI), pulsatility index (PI), Time-averaged mean velocity, impedance of blood flow (AB or systolic/diastolic [S/D] velocity ratio), peak velocity of blood flow and blood flow acceleration. Examinations started 2 weeks after breeding and continued at 2-week intervals until parturition. Outcomes for sheep and goats were similar and will be discussed together. Based on noninvasive color Doppler sonography, blood flow volume increased (approximately 60-fold, P sheep and goats. Furthermore, for uterine artery blood flow, there was an effect of stage of pregnancy on PI and RI (P sheep and goats, respectively, and then decreased until parturition. Similar to PI and RI, vascular impedance of the uterine decreased (P < 0.0001) throughout pregnancy. This is apparently the first study using noninvasive color Doppler sonography of uterine blood flow throughout physiological pregnancy in small ruminants. Clearly, this technology facilitates repeated, noninvasive assessments, with great potential for future studies.

  7. Experimental investigation of a rapidly rotating turbulent duct flow

    Energy Technology Data Exchange (ETDEWEB)

    Maartensson, G.E.; Johansson, A.V. [Department of Mechanics, KTH, 10044 Stockholm (Sweden); Gunnarsson, J. [Bombardier Transportation, Vaesteraas (Sweden); Moberg, H. [Alfa Laval, 14780 Tumba (Sweden)

    2002-09-01

    Rapidly rotating duct flow is studied experimentally with Rotation numbers in the interval. To achieve this, in combination with relatively high Reynolds numbers (5,000-30,000 based on the hydraulic radius), water was used as the working medium. Square and rectangular duct cross-sections were used and the angle between the rotation vector and the main axis of the duct was varied. The influence of the rotation on the pressure drop in the duct was investigated and suitable scalings of this quantity were studied. (orig.)

  8. Fast color flow mode imaging using plane wave excitation and temporal encoding

    DEFF Research Database (Denmark)

    Udesen, Jesper; Gran, Fredrik; Jensen, Jørgen Arendt

    2005-01-01

    In conventional ultrasound color flow mode imaging, a large number (~500) of pulses have to be emitted in order to form a complete velocity map. This lowers the frame-rate and temporal resolution. A method for color flow imaging in which a few (~10) pulses have to be emitted to form a complete...... deviation of 0.84% and a relative bias of 5.74%. Finally the method is tested on the common carotid artery of a healthy 33-year-old male....

  9. Probing the Color Glass Condensate in $pp$ collisions at forward rapidities and very low transverse momenta

    CERN Document Server

    Goncalves, V P

    2012-01-01

    The description of the hadron production at very forward rapidities and low transverse momentum is usually made using phenomenological models based on nonperturbative physics. However, at high energies and large rapidities the wave function of one of the projectiles is probed at very small Bjorken $x$, being characterized by a large number of gluons. In this kinematical regime, a new state of matter - the Color Glass Condensate (CGC) - is expected to be formed. One the main characteristics of such system is the presence of a new dynamical momentum scale, the saturation scale $Q_s$, which can assume values very larger than the QCD confinement scale $\\Lambda_{QCD}$ and give the scale of the running coupling constant. In this paper we assume that in particular kinematical region probed by LHC forward (LHCf) experiment the saturation scale can be considered the hard momentum scale present in the process and calculate the forward neutral pion production at very low-$p_T$ using a perturbative approach. We demonstra...

  10. Probing the Color Glass Condensate in pp collisions at forward rapidities and very low transverse momenta

    Science.gov (United States)

    Gonçalves, V. P.; da Silva, M. L. L.

    2013-05-01

    The description of the hadron production at very forward rapidities and low transverse momentum is usually made using phenomenological models based on nonperturbative physics. However, at high energies and large rapidities the wave function of one of the projectiles is probed at very small Bjorken x, being characterized by a large number of gluons. In this kinematical regime, a new state of matter — the Color Glass Condensate (CGC) — is expected to be formed. One the main characteristics of such system is the presence of a new dynamical momentum scale, the saturation scale Qs, which can assume values very larger than the QCD confinement scale ΛQCD and give the scale of the running coupling constant. In this paper we assume that in particular kinematical region probed by LHC forward (LHCf) experiment the saturation scale can be considered the hard momentum scale present in the process and calculate the forward neutral pion production at very low-pT using a perturbative approach. We demonstrate that the CGC formalism is able to successfully describe the LHCf data, which can be considered as a compelling indication of the presence of non-linear QCD effects at LHC energies.

  11. Bacterial floc mediated rapid streamer formation in creeping flows

    CERN Document Server

    Hassanpourfard, Mahtab; Ghosh, Ranajay; Das, Siddhartha; Thundat, Thomas; Liu, Yang; Kumar, Aloke

    2015-01-01

    One of the central puzzles concerning the interaction of low Reynolds number (Re<<1) fluid transport with bacterial biomass is the formation of filamentous structures called streamers. In this manuscript, we report our discovery of a new kind of low Re bacterial streamers, which appear from pre-formed bacterial flocs. In sharp contrast to the biofilm-mediated streamers, these streamers form over extremely small timescales (less than a second). Our experiments, carried out in a microchannel with micropillars rely on fluorescence microscopy techniques to illustrate that floc-mediated streamers form when a freely-moving floc adheres to the micropillar wall and gets rapidly sheared by the background flow. We also show that at their inception the deformation of the flocs is dominated by recoverable large strains indicating significant elasticity. These strains subsequently increase tremendously to produce filamentous streamers. Interestingly, we find that these fully formed streamers are not static structure...

  12. Goulphar: rapid access and expertise for standard two-color microarray normalization methods

    Directory of Open Access Journals (Sweden)

    Servant Nicolas

    2006-10-01

    Full Text Available Abstract Background Raw data normalization is a critical step in microarray data analysis because it directly affects data interpretation. Most of the normalization methods currently used are included in the R/BioConductor packages but it is often difficult to identify the most appropriate method. Furthermore, the use of R commands for functions and graphics can introduce mistakes that are difficult to trace. We present here a script written in R that provides a flexible means of access to and monitoring of data normalization for two-color microarrays. This script combines the power of BioConductor and R analysis functions and reduces the amount of R programming required. Results Goulphar was developed in and runs using the R language and environment. It combines and extends functions found in BioConductor packages (limma and marray to correct for dye biases and spatial artifacts. Goulphar provides a wide range of optional and customizable filters for excluding incorrect signals during the pre-processing step. It displays informative output plots, enabling the user to monitor the normalization process, and helps adapt the normalization method appropriately to the data. All these analyses and graphical outputs are presented in a single PDF report. Conclusion Goulphar provides simple, rapid access to the power of the R/BioConductor statistical analysis packages, with precise control and visualization of the results obtained. Complete documentation, examples and online forms for setting script parameters are available from http://transcriptome.ens.fr/goulphar/.

  13. Continuous-Flow Detector for Rapid Pathogen Identification

    Energy Technology Data Exchange (ETDEWEB)

    Barrett, Louise M. [Sandia National Lab. (SNL-CA), Livermore, CA (United States). Microfluidics; Skulan, Andrew J. [Sandia National Lab. (SNL-CA), Livermore, CA (United States). Microfluidics; Singh, Anup K. [Sandia National Lab. (SNL-CA), Livermore, CA (United States). Microfluidics; Cummings, Eric B. [Sandia National Lab. (SNL-CA), Livermore, CA (United States). Microfluidics; Fiechtner, Gregory J. [Sandia National Lab. (SNL-CA), Livermore, CA (United States). Microfluidics

    2006-09-01

    This report describes the continued development of a low-power, portable detector for the rapid identification of pathogens such as B. anthracis and smallpox. Based on our successful demonstration of the continuous filter/concentrator inlet, we believe strongly that the inlet section will enable differentiation between viable and non-viable populations, between types of cells, and between pathogens and background contamination. Selective, continuous focusing of particles in a microstream enables highly selective and sensitive identification using fluorescently labeled antibodies and other receptors such as peptides, aptamers, or small ligands to minimize false positives. Processes such as mixing and lysing will also benefit from the highly localized particle streams. The concentrator is based on faceted prisms to contract microfluidic flows while maintaining uniform flowfields. The resulting interfaces, capable of high throughput, serve as high-, low-, and band-pass filters to direct selected bioparticles to a rapid, affinity-based detection system. The proposed device is superior to existing array-based detectors as antibody-pathogen binding can be accomplished in seconds rather than tens of minutes or even hours. The system is being designed to interface with aerosol collectors under development by the National Laboratories or commercial systems. The focused stream is designed to be interrogated using diode lasers to differentiate pathogens by light scattering. Identification of particles is done using fluorescently labeled antibodies to tag the particles, followed by multiplexed laser-induced fluorescence (LIF) detection (achieved by labeling each antibody with a different dye).

  14. Translating Colored Control Flow Nets into Readable Java via Annotated Java Workflow Nets

    DEFF Research Database (Denmark)

    Lassen, Kristian Bisgaard; Tjell, Simon

    2007-01-01

    In this paper, we present a method for developing Java applications from Colored Control Flow Nets (CCFNs), which is a special kind of Colored Petri Nets (CPNs) that we introduce. CCFN makes an explicit distinction between the representation of: The system, the environment of the system, and the ......In this paper, we present a method for developing Java applications from Colored Control Flow Nets (CCFNs), which is a special kind of Colored Petri Nets (CPNs) that we introduce. CCFN makes an explicit distinction between the representation of: The system, the environment of the system......, and the interface between the system and the environment. Our translation maps CCFNs into Anno- tated Java Workflow Nets (AJWNs) as an intermediate step, and these AJWNs are finally mapped to Java. CCFN is intended to enforce the modeler to describe the system in an imperative manner which makes the subsequent...... translation to Java easier to define. The translation to Java preserves data dependencies and control-flow aspects of the source CCFN. This paper contributes to the model-driven software development paradigm, by showing how to model a system, environment, and their interface, as a CCFN and presenting a fully...

  15. High-Contrast Color-Stripe Pattern for Rapid Structured-Light Range Imaging

    CERN Document Server

    Je, Changsoo; Park, Rae-Hong

    2015-01-01

    For structured-light range imaging, color stripes can be used for increasing the number of distinguishable light patterns compared to binary BW stripes. Therefore, an appropriate use of color patterns can reduce the number of light projections and range imaging is achievable in single video frame or in "one shot". On the other hand, the reliability and range resolution attainable from color stripes is generally lower than those from multiply projected binary BW patterns since color contrast is affected by object color reflectance and ambient light. This paper presents new methods for selecting stripe colors and designing multiple-stripe patterns for "one-shot" and "two-shot" imaging. We show that maximizing color contrast between the stripes in one-shot imaging reduces the ambiguities resulting from colored object surfaces and limitations in sensor/projector resolution. Two-shot imaging adds an extra video frame and maximizes the color contrast between the first and second video frames to diminish the ambigui...

  16. Rapid production of structural color images with optical data storage capabilities

    Science.gov (United States)

    Rezaei, Mohamad; Jiang, Hao; Qarehbaghi, Reza; Naghshineh, Mohammad; Kaminska, Bozena

    2015-03-01

    In this paper, we present novel methods to produce structural color image for any given color picture using a pixelated generic stamp named nanosubstrate. The nanosubstrate is composed of prefabricated arrays of red, green and blue subpixels. Each subpixel has nano-gratings and/or sub-wavelength structures which give structural colors through light diffraction. Micro-patterning techniques were implemented to produce the color images from the nanosubstrate by selective activation of subpixels. The nano-grating structures can be nanohole arrays, which after replication are converted to nanopillar arrays or vice versa. It has been demonstrated that visible and invisible data can be easily stored using these fabrication methods and the information can be easily read. Therefore the techniques can be employed to produce personalized and customized color images for applications in optical document security and publicity, and can also be complemented by combined optical data storage capabilities.

  17. A simple and rapid chromatographic method to determine unauthorized basic colorants (rhodamine B, auramine O, and pararosaniline) in processed foods.

    Science.gov (United States)

    Tatebe, Chiye; Zhong, Xining; Ohtsuki, Takashi; Kubota, Hiroki; Sato, Kyoko; Akiyama, Hiroshi

    2014-09-01

    A simple and rapid high-performance liquid chromatography (HPLC) method to determine basic colorants such as pararosaniline (PA), auramine O (AO), and rhodamine B (RB) in various processed foods was developed. Linearity of the calibration curves ranged from 0.05 to 50 μg/mL for PA and 0.05-100 μg/mL for AO and RB. The detection and quantification limits (LOD and LOQ) of the basic colorants, which were evaluated as signal-to-noise ratios of 3 for LOD and 10 for LOQ, ranged from 0.0125 to 0.05 and 0.025 to 0.125 μg/g, respectively. The recoveries and relative standard deviations of three basic colorants in six processed foods, namely, chili sauce, curry paste, gochujang (hot pepper paste), tandoori chicken (roasted chicken prepared with yogurt and spices), powder soup, and shrimp powder ranged from 70.2% to 102.8% and 0.8% to 8.0%, respectively. The intraday precision of the recovery test ranged from 1.7% to 4.5%, whereas the interday precision ranged from 3.7% to 7.7%. The reported method has been successfully applied to basic colorant determination in various processed foods such as fat-based food matrices (curry paste and tandoori chicken), chili products (gochujang and chili sauce), and protein-based products (shrimp powder and powder soup). Thin layer chromatography and liquid chromatography/mass spectrometry methods for the determination of basic colorants in processed foods were also developed for rapid analysis and identification, respectively. These methods are very useful for monitoring unauthorized basic colorants in inspection centers or quarantine laboratories in many countries.

  18. Color encoded microbeads-based flow cytometric immunoassay for polycyclic aromatic hydrocarbons in food

    Energy Technology Data Exchange (ETDEWEB)

    Meimaridou, Anastasia, E-mail: anastasia.meimaridou@wur.nl [RIKILT-Institute of Food Safety, Wageningen UR, P.O. Box 230, 6700 AE Wageningen (Netherlands); Haasnoot, Willem; Noteboom, Linda; Mintzas, Dimitrios [RIKILT-Institute of Food Safety, Wageningen UR, P.O. Box 230, 6700 AE Wageningen (Netherlands); Pulkrabova, Jana; Hajslova, Jana [Department of Food Chemistry and Analysis, Institute of Chemical Technology Prague, Technicka 3, 166 28 Prague 6 (Czech Republic); Nielen, Michel W.F. [RIKILT-Institute of Food Safety, Wageningen UR, P.O. Box 230, 6700 AE Wageningen (Netherlands); Wageningen University, Laboratory of Organic Chemistry, Dreijenplein 8, 6703 HB Wageningen (Netherlands)

    2010-07-05

    Food contamination caused by chemical hazards such as persistent organic pollutants (POPs) is a worldwide public health concern and requires continuous monitoring. The chromatography-based analysis methods for POPs are accurate and quite sensitive but they are time-consuming, laborious and expensive. Thus, there is a need for validated simplified screening tools, which are inexpensive, rapid, have automation potential and can detect multiple POPs simultaneously. In this study we developed a flow cytometry-based immunoassay (FCIA) using a color-encoded microbeads technology to detect benzo[a]pyrene (BaP) and other polycyclic aromatic hydrocarbons (PAHs) in buffer and food extracts as a starting point for the future development of rapid multiplex assays including other POPs in food, such as polychlorinated biphenyls (PCBs) and polybrominated diphenyl ethers (PBDEs). A highly sensitive assay for BaP was obtained with an IC{sub 50} of 0.3 {mu}g L{sup -1} using a monoclonal antibody (Mab22F12) against BaP, similar to the IC{sub 50} of a previously described enzyme-linked immunosorbent assay (ELISA) using the same Mab. Moreover, the FCIA was 8 times more sensitive for BaP compared to a surface plasmon resonance (SPR)-based biosensor immunoassay (BIA) using the same reagents. The selectivity of the FCIAs was tested, with two Mabs against BaP for 25 other PAHs, including two hydroxyl PAH metabolites. Apart from BaP, the FCIAs can detect PAHs such as indenol[1,2,3-cd]pyrene (IP), benz[a]anthracene (BaA), and chrysene (CHR) which are also appointed by the European Food Safety Authority (EFSA) as suitable indicators of PAH contamination in food. The FCIAs results were in agreement with those obtained with gas chromatography-mass spectrometry (GC-MS) for the detection of PAHs in real food samples of smoked carp and wheat flour and has great potential for the future routine application of this assay in a simplex or multiplex format in combination with simplified extraction

  19. Normal reference values for vertebral artery flow volume by color Doppler sonography in Korean adults

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Hyun Sook; Cha, Jang Gyu; Park, Seong Jin; Joh, Joon Hee; Park, Jai Soung; Kim, Dae Ho; Lee, Hae Kyung; Ahn, Hyun Cheol [Soonchunhyang University Bucheon Hospital, Bucheon (Korea, Republic of)

    2003-09-15

    Vertebrobasilar ischemia has been attributed to a reduction of net vertebral artery flow volume. This study was to establish the reference values for the flow volume of the vertebral artery using color Doppler sonography in the normal Korea adults. Thirty five normal Korea adults without any underlying disease including hypertension, hyperlipidemia, diabetes, heart disease, obesity (body mas index>30), or carotid artery stenosis was included. There were 17 males and 18 females, age ranged from 20 to 53 years (average=32.86 years). Flow velocities and vessel diameters were recorded in the intertransverse (V2) segment, usually at C5-6 level, bilaterally. The flow volume (Q) was calculated. (Q=time averaged mean velocity x cross sectional area of vessel) A lower Flow velocity and smaller vessel diameter were measured on the right side compared to those of the left side, resulting in a lower flow volume. The calculated flow volumes using the equation were 77.0 +- 39.7 ml/min for the right side and 127.6 +- 71.0 ml/min for the left side (p=0.0001) while the net vertebral artery flow volume was 204.6 +- 81.8 ml/min. Decrease in the vertebral artery flow volume was statistically significant with advanced age. (r=-0.36, p=0.032). Vertebral artery blood flow volume was 191.20 +- 59.19 ml/min in male, and 217.28 +- 98.67 ml/min in female (p=0.6). The normal range for the net vertebral artery flow volume defined by the 5th to 95th percentiles was between 110.06 and 364.1 ml/min. The normal range for the net vertebral artery flow volume was between 110.06 and 364.1 ml/min. Vertebral artery flow volume decreased with the increase of age. However, gender did not affect the blood flow volume.

  20. Tests of models of color reconnection and a search for glueballs using gluon jets with a rapidity gap

    CERN Document Server

    Abbiendi, G.; Akesson, P.F.; Alexander, G.; Allison, John; Amaral, P.; Anagnostou, G.; Anderson, K.J.; Arcelli, S.; Asai, S.; Axen, D.; Azuelos, G.; Bailey, I.; Barberio, E.; Barlow, R.J.; Batley, R.J.; Bechtle, P.; Behnke, T.; Bell, Kenneth Watson; Bell, P.J.; Bella, G.; Bellerive, A.; Benelli, G.; Bethke, S.; Biebel, O.; Boeriu, O.; Bock, P.; Boutemeur, M.; Braibant, S.; Brigliadori, L.; Brown, Robert M.; Buesser, K.; Burckhart, H.J.; Campana, S.; Carnegie, R.K.; Caron, B.; Carter, A.A.; Carter, J.R.; Chang, C.Y.; Charlton, David G.; Csilling, A.; Cuffiani, M.; Dado, S.; De Roeck, A.; De Wolf, E.A.; Desch, K.; Dienes, B.; Donkers, M.; Dubbert, J.; Duchovni, E.; Duckeck, G.; Duerdoth, I.P.; Etzion, E.; Fabbri, F.; Feld, L.; Ferrari, P.; Fiedler, F.; Fleck, I.; Ford, M.; Frey, A.; Furtjes, A.; Gagnon, P.; Gary, John William; Gaycken, G.; Geich-Gimbel, C.; Giacomelli, G.; Giacomelli, P.; Giunta, Marina; Goldberg, J.; Gross, E.; Grunhaus, J.; Gruwe, M.; Gunther, P.O.; Gupta, A.; Hajdu, C.; Hamann, M.; Hanson, G.G.; Harder, K.; Harel, A.; Harin-Dirac, M.; Hauschild, M.; Hawkes, C.M.; Hawkings, R.; Hemingway, R.J.; Hensel, C.; Herten, G.; Heuer, R.D.; Hill, J.C.; Hoffman, Kara Dion; Horvath, D.; Igo-Kemenes, P.; Ishii, K.; Jeremie, H.; Jovanovic, P.; Junk, T.R.; Kanaya, N.; Kanzaki, J.; Karapetian, G.; Karlen, D.; Kawagoe, K.; Kawamoto, T.; Keeler, R.K.; Kellogg, R.G.; Kennedy, B.W.; Kim, D.H.; Klein, K.; Klier, A.; Kluth, S.; Kobayashi, T.; Kobel, M.; Komamiya, S.; Kormos, Laura L.; Kramer, T.; Krieger, P.; von Krogh, J.; Kruger, K.; Kuhl, T.; Kupper, M.; Lafferty, G.D.; Landsman, H.; Lanske, D.; Layter, J.G.; Leins, A.; Lellouch, D.; Lettso, J.; Levinson, L.; Lillich, J.; Lloyd, S.L.; Loebinger, F.K.; Lu, J.; Ludwig, J.; Macpherson, A.; Mader, W.; Marcellini, S.; Martin, A.J.; Masetti, G.; Mashimo, T.; Mattig, Peter; McDonald, W.J.; McKenna, J.; McMahon, T.J.; McPherson, R.A.; Meijers, F.; Menges, W.; Merritt, F.S.; Mes, H.; Michelini, A.; Mihara, S.; Mikenberg, G.; Miller, D.J.; Moed, S.; Mohr, W.; Mori, T.; Mutter, A.; Nagai, K.; Nakamura, I.; Nanjo, H.; Neal, H.A.; Nisius, R.; O'Neale, S.W.; Oh, A.; Okpara, A.; Oreglia, M.J.; Orito, S.; Pahl, C.; Pasztor, G.; Pater, J.R.; Patrick, G.N.; Pilcher, J.E.; Pinfold, J.; Plane, David E.; Poli, B.; Polok, J.; Pooth, O.; Przybycien, M.; Quadt, A.; Rabbertz, K.; Rembser, C.; Renkel, P.; Roney, J.M.; Rosati, S.; Rozen, Y.; Runge, K.; Sachs, K.; Saeki, T.; Sarkisyan, E.K.G.; Schaile, A.D.; Schaile, O.; Scharff-Hansen, P.; Schieck, J.; Schoerner-Sadenius, Thomas; Schroder, Matthias; Schumacher, M.; Schwick, C.; Scott, W.G.; Seuster, R.; Shears, T.G.; Shen, B.C.; Sherwood, P.; Siroli, G.; Skuja, A.; Smith, A.M.; Sobie, R.; Soldner-Rembold, S.; Spano, F.; Stahl, A.; Stephens, K.; Strom, David M.; Strohmer, R.; Tarem, S.; Tasevsky, M.; Taylor, R.J.; Teuscher, R.; Thomson, M.A.; Torrence, E.; Toya, D.; Tran, P.; Trigger, I.; Trocsanyi, Z.; Tsur, E.; Turner-Watson, M.F.; Ueda, I.; Ujvari, B.; Vollmer, C.F.; Vannerem, P.; Vertesi, R.; Verzocchi, M.; Voss, H.; Vossebeld, J.; Waller, D.; Ward, C.P.; Ward, D.R.; Watkins, P.M.; Watson, A.T.; Watson, N.K.; Wells, P.S.; Wengler, T.; Wermes, N.; Wetterling, D.; Wilson, G.W.; Wilson, J.A.; Wolf, G.; Wyatt, T.R.; Yamashita, S.; Zer-Zion, D.; Zivkovic, Lidija

    2004-01-01

    Gluon jets with a mean energy of 22 GeV and purity of 95% are selected from hadronic Z0 decay events produced in e+e- annihilations. A subsample of these jets is identified which exhibits a large gap in the rapidity distribution of particles within the jet. After imposing the requirement of a rapidity gap, the gluon jet purity is 86%. These jets are observed to demonstrate a high degree of sensitivity to the presence of color reconnection, i.e. higher order QCD processes affecting the underlying color structure. We use our data to test three QCD models which include a simulation of color reconnection: one in the Ariadne Monte Carlo, one in the Herwig Monte Carlo, and the other by Rathsman in the Pythia Monte Carlo. We find the Rathsman and Ariadne color reconnection models can describe our gluon jet measurements only if very large values are used for the cutoff parameters which serve to terminate the parton showers, and that the description of inclusive Z0 data is significantly degraded in this case. We concl...

  1. Magnetohydrodynamics flow over a rapidly rotating axisymmetric wavy disk

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Myung Sup [Korea Testing Laboratory, 222-13 Guro3-dong Guro-gu, Seoul 152-718 (Korea, Republic of); Park, Jun Sang [Department of Mechanical Engineering, Halla University, Halla dae 1-gil, HeungUp, Wonju, Kangwon-do 220-712 (Korea, Republic of); Hyun, Jae Min, E-mail: jspark@halla.ac.kr [Department of Mechanical Engineering, Korea Advanced Institute of Science and Technology, 373-1 Kusong-dong, Yusong-gu, Taejon 305-701 (Korea, Republic of)

    2011-08-15

    A numerical study of Magnetohydrodynamics boundary layer flow over a rapidly rotating wavy disc was performed under which magnetic fields are imposed by a circular electric coil. The shape of the disc is assumed to be axisymmetric and sinusoidal in the radial direction, and semi-infinite space over the disc steadily rotating is occupied by an electrically conducting fluid. The study was conducted for the case where the representative Reynolds number is very large and the magnetic Reynolds number is negligibly small. The effect of Lorentz force on fluid motion was precisely investigated as the main external controlling force. The generalized boundary layer equation, including both magnetic field and heat flux, is derived to examine interactions among the effects of wavy surface shape, magnetic field and heat flux from the disc surface. Two cases of uniform magnetic field, much studied in previous research, and of non-uniform magnetic field, realized by a circular coil, have been scrutinized. Details of velocity profile, skin friction coefficient and heat transfer coefficient are given.

  2. A Rapid, Multiplexed, High-Throughput Flow-Through Membrane Immunoassay: A Convenient Alternative to ELISA

    Directory of Open Access Journals (Sweden)

    Gonzalo J. Domingo

    2013-04-01

    Full Text Available This paper describes a rapid, high-throughput flow-through membrane immunoassay (FMIA platform. A nitrocellulose membrane was spotted in an array format with multiple capture and control reagents for each sample detection area, and assay steps were carried out by sequential aspiration of sample and reagents through each detection area using a 96-well vacuum manifold. The FMIA provides an alternate assay format with several advantages over ELISA. The high surface area of the membrane permits high label concentration using gold labels, and the small pores and vacuum control provide rapid diffusion to reduce total assay time to ~30 min. All reagents used in the FMIA are compatible with dry storage without refrigeration. The results appear as colored spots on the membrane that can be quantified using a flatbed scanner. We demonstrate the platform for detection of IgM specific to lipopolysaccharides (LPS derived from Salmonella Typhi. The FMIA format provides analytical results comparable to ELISA in less time, provides integrated assay controls, and allows compensation for specimen-to-specimen variability in background, which is a particular challenge for IgM assays.

  3. Color Doppler Ultrasound Velocimetry Flow Reconstruction using Vorticity-Streamfunction Formulation

    Science.gov (United States)

    Meyers, Brett; Vlachos, Pavlos; Goergen, Craig; Scalo, Carlo

    2016-11-01

    Clinicians commonly utilize Color Doppler imaging to qualitatively assess the velocity in patient cardiac or arterial flows. However Color Doppler velocity are restricted to two-dimensional one-component measurements. Recently new methods have been proposed to reconstruct a two-component velocity field from such data. Vector Flow Mapping (VFM), in particular, utilizes the conservation of mass to reconstruct the flow. However, this method over-simplifies the influence of wall and surrounding blood motion on local measurements, which produce large, non-physical velocity gradients, requiring excessive smoothing operations to remove. We propose a new approach based on the Vorticity-Stream Function (Ψ- ω) formulation that yields more physiologically accurate velocity gradients and avoids any added smoothing operations. Zero-penetration conditions are specified at the walls, removing the need for measurement of wall velocity from additional scans, which introduce further uncertainties in the reconstruction. Inflow and outflow boundary conditions are incorporated by prescribing Dirichlet boundary conditions. The proposed solver is compared against the VFM using computational data to evaluate measurement improvement. Finally we demonstrate the method by evaluating murine left ventricle Color Doppler scans.

  4. Testing tubewell platform color as a rapid screening tool for arsenic and manganese in drinking water wells.

    Science.gov (United States)

    Biswas, Ashis; Nath, Bibhash; Bhattacharya, Prosun; Halder, Dipti; Kundu, Amit K; Mandal, Ujjal; Mukherjee, Abhijit; Chatterjee, Debashis; Jacks, Gunnar

    2012-01-03

    A low-cost rapid screening tool for arsenic (As) and manganese (Mn) in groundwater is urgently needed to formulate mitigation policies for sustainable drinking water supply. This study attempts to make statistical comparison between tubewell (TW) platform color and the level of As and Mn concentration in groundwater extracted from the respective TW (n = 423), to validate platform color as a screening tool for As and Mn in groundwater. The result shows that a black colored platform with 73% certainty indicates that well water is safe from As, while with 84% certainty a red colored platform indicates that well water is enriched with As, compared to WHO drinking water guideline of 10 μg/L. With this guideline the efficiency, sensitivity, and specificity of the tool are 79%, 77%, and 81%, respectively. However, the certainty values become 93% and 38%, respectively, for black and red colored platforms at 50 μg/L, the drinking water standards for India and Bangladesh. The respective efficiency, sensitivity, and specificity are 65%, 85%, and 59%. Similarly for Mn, black and red colored platform with 78% and 64% certainty, respectively, indicates that well water is either enriched or free from Mn at the Indian national drinking water standard of 300 μg/L. With this guideline the efficiency, sensitivity, and specificity of the tool are 71%, 67%, and 76%, respectively. Thus, this study demonstrates that TW platform color can be potentially used as an initial screening tool for identifying TWs with elevated dissolved As and Mn, to make further rigorous groundwater testing more intensive and implement mitigation options for safe drinking water supplies.

  5. Primate genotyping via high resolution melt analysis: rapid and reliable identification of color vision status in wild lemurs.

    Science.gov (United States)

    Jacobs, Rachel L; Spriggs, Amanda N; MacFie, Tammie S; Baden, Andrea L; Irwin, Mitchell T; Wright, Patricia C; Louis, Edward E; Lawler, Richard R; Mundy, Nicholas I; Bradley, Brenda J

    2016-10-01

    Analyses of genetic polymorphisms can aid our understanding of intra- and interspecific variation in primate sociality, ecology, and behavior. Studies of primate opsin genes are prime examples of this, as single nucleotide variants (SNVs) in the X-linked opsin gene underlie variation in color vision. For primate species with polymorphic trichromacy, genotyping opsin SNVs can generally indicate whether individual primates are red-green color-blind (denoted homozygous M or homozygous L) or have full trichromatic color vision (heterozygous ML). Given the potential influence of color vision on behavior and fitness, characterizing the color vision status of study subjects is becoming commonplace for many primate field projects. Such studies traditionally involve a multi-step sequencing-based method that can be costly and time-consuming. Here we present a new reliable, rapid, and relatively inexpensive method for characterizing color vision in primate populations using high resolution melt analysis (HRMA). Using lemurs as a case study, we characterized variation at exons 3 and/or 5 of the X-linked opsin gene for 87 individuals representing nine species. We scored opsin genotypes and color vision status using both traditional sequencing-based methods as well as our novel melting-curve based HRMA protocol. For each species, the melting curves of varying genotypes (homozygous M, homozygous L, heterozygous ML) differed in melting temperature and/or shape. Melting curves for each sample were consistent across replicates, and genotype-specific melting curves were consistent across DNA sources (blood vs. feces). We show that opsin genotypes can be quickly and reliably scored using HRMA once lab-specific reference curves have been developed based on known genotypes. Although the protocol presented here focuses on genotyping lemur opsin loci, we also consider the larger potential for applying this approach to various types of genetic studies of primate populations.

  6. Modelling rapid subsurface flow at the hillslope scale with explicit representation of preferential flow paths

    Science.gov (United States)

    Wienhöfer, J.; Zehe, E.

    2012-04-01

    Rapid lateral flow processes via preferential flow paths are widely accepted to play a key role for rainfall-runoff response in temperate humid headwater catchments. A quantitative description of these processes, however, is still a major challenge in hydrological research, not least because detailed information about the architecture of subsurface flow paths are often impossible to obtain at a natural site without disturbing the system. Our study combines physically based modelling and field observations with the objective to better understand how flow network configurations influence the hydrological response of hillslopes. The system under investigation is a forested hillslope with a small perennial spring at the study area Heumöser, a headwater catchment of the Dornbirnerach in Vorarlberg, Austria. In-situ points measurements of field-saturated hydraulic conductivity and dye staining experiments at the plot scale revealed that shrinkage cracks and biogenic macropores function as preferential flow paths in the fine-textured soils of the study area, and these preferential flow structures were active in fast subsurface transport of artificial tracers at the hillslope scale. For modelling of water and solute transport, we followed the approach of implementing preferential flow paths as spatially explicit structures of high hydraulic conductivity and low retention within the 2D process-based model CATFLOW. Many potential configurations of the flow path network were generated as realisations of a stochastic process informed by macropore characteristics derived from the plot scale observations. Together with different realisations of soil hydraulic parameters, this approach results in a Monte Carlo study. The model setups were used for short-term simulation of a sprinkling and tracer experiment, and the results were evaluated against measured discharges and tracer breakthrough curves. Although both criteria were taken for model evaluation, still several model setups

  7. Evaluation of patients with thyrotoxic autoimmune thyroiditis by color flow doppler ultrasonography

    Directory of Open Access Journals (Sweden)

    Ömer Karakaş

    2013-03-01

    Full Text Available Objective: In this study, we aimed to examine the availabilityand the effects of differential diagnosis of thyroidgland morphological changes and blood flow patterns inpatients with thyrotoxic phase Graves’ disease (BGDand Hashimoto’s thyroiditis (HT by color flow doppler ultrasonography(CDUS.Methods: This cross-sectional study was included 24consecutive patients with thyrotoxicosis and 18 healthycontrols. There were Basedow-Graves’ disease in 17 andHashimoto thyroiditis in 7 of previously untreated 24 patients.Morphological information of thyroid gland was obtainedby B-mode ultrasonography in all cases. Blood flowpattern of the thyroid gland was determined by CDUS.Results: The thyroid volumes and FT3, TRAb, 4-h and24-h RAIU levels of the patients with Graves’s diseasewere significantly higher than the patients with HT.Whereas thyroid gland echogenicity was decreased in 14of BGH cases, it was diminished in 2 patients with HT.Significant difference was found between BGD and HTgroups in terms of thyroid gland echogenicity. In all patientswith BGD and HT, echopattern was heterogenous.In all patients, blood flow patterns of thyroid gland wereobtained by CDUS. Color flow doppler ultrasonographyand pattern 3 blood flows were only observed in BGD.Significant difference was found between HT and BGDgroups in blood flow pattern.Conclusion: Heterojen echopattern, decreased echogenicity,volume changes and type 3 blood flow patternof thyroid gland obtained using B-mode Ultrasound andCDUS may be useful in the determination and differentiationof thyrotoxic BGD and HT diseases. J Clin Exp Invest2013; 4 (1: 73-79Key words: Doppler ultrasonography, autoimmune thyroiditis,thyrotoxicosis

  8. Adaptive clutter filter in 2-D color flow imaging based on in vivo I/Q signal.

    Science.gov (United States)

    Zhou, Xiaoming; Zhang, Congyao; Liu, Dong C

    2014-01-01

    Color flow imaging has been well applied in clinical diagnosis. For the high quality color flow images, clutter filter is important to separate the Doppler signals from blood and tissue. Traditional clutter filters, such as finite impulse response, infinite impulse response and regression filters, were applied, which are based on the hypothesis that the clutter signal is stationary or tissue moves slowly. However, in realistic clinic color flow imaging, the signals are non-stationary signals because of accelerated moving tissue. For most related papers, simulated RF signals are widely used without in vivo I/Q signal. Hence, in this paper, adaptive polynomial regression filter, which is down mixing with instantaneous clutter frequency, was proposed based on in vivo carotid I/Q signal in realistic color flow imaging. To get the best performance, the optimal polynomial order of polynomial regression filter and the optimal polynomial order for estimation of instantaneous clutter frequency respectively were confirmed. Finally, compared with the mean blood velocity and quality of 2-D color flow image, the experiment results show that adaptive polynomial regression filter, which is down mixing with instantaneous clutter frequency, can significantly enhance the mean blood velocity and get high quality 2-D color flow image.

  9. Stereoscopic PIV on multiple color-coded light sheets and its application to axial flow in flapping robotic insect wings

    Science.gov (United States)

    Pick, Simon; Lehmann, Fritz-Olaf

    2009-12-01

    Non-scanning volume flow measurement techniques such as 3D-PTV, holographic and tomographic particle image velocimetry (PIV) permit reconstructions of all three components (3C) of velocity and vorticity vectors in a fluid volume (3D). In this study, we present a novel 3D3C technique termed Multiple-Color-Plane Stereo Particle-Image-Velocimetry (color PIV), which allows instantaneous measurements of 3C velocity vectors in six parallel, colored light sheets. We generated the light sheets by passing white light of two strobes through dichroic color filters and imaged the slices by two 3CCD color cameras in Stereo-PIV configuration. The stereo-color images were processed by custom software routines that sorted each colored fluid particle into one of six gray-scale images according to its hue, saturation, and luminance. We used conventional Stereo PIV cross-correlation algorithms to compute a 3D planar vector field for each light sheet and subsequently interpolated a volume flow map from the six vector fields. As a first application, we quantified the wake and axial flow in the vortical structures of a robotic insect (fruit fly) model wing. In contrast to previous findings, the measured data indicate strong axial flow components on the upper wing surface, including axial flow in the leading-edge vortex core. Collectively, color PIV is robust against mechanical misalignments, avoids laser safety issues, and computes instantaneous 3D vector fields in a fraction of the time typical for other 3D systems. Color PIV might thus be of value for volume measurements of highly unsteady flows.

  10. Rapid method for quantification of seven synthetic pigments in colored Chinese steamed buns using UFLC-MS/MS without SPE.

    Science.gov (United States)

    Gao, He-Gang; Gong, Wen-Jie; Zhao, Yong-Gang

    2015-01-01

    Synthetic pigments are still used instead of natural pigments in many foods and their residues in food could be an important risk to human health. A simple and rapid analytical method combining the low-cost extraction protocol with ultra-fast liquid chromatography-tandem quadrupole mass spectrometry (UFLC-MS/MS) was developed for the simultaneous determination of seven synthetic pigments used in colored Chinese steamed buns. For the first time, ethanol/ammonia solution/water (7:2:1, v/v/v) was used as extraction solution for the synthetic pigments in colored Chinese steamed buns. The results showed that the property of the extraction solution used in this method was more effective than critic acid solution, which is used in the polyamide adsorption method. The limits of quantification for the seven synthetic pigments ranged from 0.15 to 0.50 μg/kg. The present method was successfully applied to samples of colored Chinese steamed buns for food-safety risk monitoring in Zhejiang Province, China. The results found sunset yellow pigment in six out of 300 colored Chinese steamed buns (from 0.50 to 32.6 μg/kg).

  11. Inverse Problem for Color Doppler Ultrasound-Assisted Intracardiac Blood Flow Imaging

    Directory of Open Access Journals (Sweden)

    Jaeseong Jang

    2016-01-01

    Full Text Available For the assessment of the left ventricle (LV, echocardiography has been widely used to visualize and quantify geometrical variations of LV. However, echocardiographic image itself is not sufficient to describe a swirling pattern which is a characteristic blood flow pattern inside LV without any treatment on the image. We propose a mathematical framework based on an inverse problem for three-dimensional (3D LV blood flow reconstruction. The reconstruction model combines the incompressible Navier-Stokes equations with one-direction velocity component of the synthetic flow data (or color Doppler data from the forward simulation (or measurement. Moreover, time-varying LV boundaries are extracted from the intensity data to determine boundary conditions of the reconstruction model. Forward simulations of intracardiac blood flow are performed using a fluid-structure interaction model in order to obtain synthetic flow data. The proposed model significantly reduces the local and global errors of the reconstructed flow fields. We demonstrate the feasibility and potential usefulness of the proposed reconstruction model in predicting dynamic swirling patterns inside the LV over a cardiac cycle.

  12. Real Data and Rapid Results: Ocean Color Data Analysis with Giovanni (GES DISC Interactive Online Visualization and ANalysis Infrastructure)

    Science.gov (United States)

    Acker, J. G.; Leptoukh, G.; Kempler, S.; Gregg, W.; Berrick, S.; Zhu, T.; Liu, Z.; Rui, H.; Shen, S.

    2004-01-01

    The NASA Goddard Earth Sciences Data and Information Services Center (GES DISC) has taken a major step addressing the challenge of using archived Earth Observing System (EOS) data for regional or global studies by developing an infrastructure with a World Wide Web interface which allows online, interactive, data analysis: the GES DISC Interactive Online Visualization and ANalysis Infrastructure, or "Giovanni." Giovanni provides a data analysis environment that is largely independent of underlying data file format. The Ocean Color Time-Series Project has created an initial implementation of Giovanni using monthly Standard Mapped Image (SMI) data products from the Sea-viewing Wide Field-of-view Sensor (SeaWiFS) mission. Giovanni users select geophysical parameters, and the geographical region and time period of interest. The system rapidly generates a graphical or ASCII numerical data output. Currently available output options are: Area plot (averaged or accumulated over any available data period for any rectangular area); Time plot (time series averaged over any rectangular area); Hovmeller plots (image view of any longitude-time and latitude-time cross sections); ASCII output for all plot types; and area plot animations. Future plans include correlation plots, output formats compatible with Geographical Information Systems (GIs), and higher temporal resolution data. The Ocean Color Time-Series Project will produce sensor-independent ocean color data beginning with the Coastal Zone Color Scanner (CZCS) mission and extending through SeaWiFS and Moderate Resolution Imaging Spectroradiometer (MODIS) data sets, and will enable incorporation of Visible/lnfrared Imaging Radiometer Suite (VIIRS) data, which will be added to Giovanni. The first phase of Giovanni will also include tutorials demonstrating the use of Giovanni and collaborative assistance in the development of research projects using the SeaWiFS and Ocean Color Time-Series Project data in the online Laboratory

  13. Practical way to develop 10-color flow cytometry protocols for the clinical laboratory

    Science.gov (United States)

    Tárnok, Attila; Bocsi, Jozsef

    2010-02-01

    The latest development of commercial routine flow cytometers (FCM) is that they are equipped with three (blue, red, violet) or more lasers and many PMT detectors. Nowadays routine clinical instruments are capable of detecting 10 or more fluorescence colors simultaneously. Thereby, presenting opportunities for getting detailed information on the single cell level for cytomics and systems biology for improve diagnostics and monitoring of patients. The University Leipzig, Germany) recently started a cluster of excellence to study the molecular background of life style and environment associated diseases, enrolling 25000 individuals (LIFE). To this end the most comprehensive FCM protocol has to be developed for this study. We aimed to optimize fluorochrome and antibody combinations to the characteristics of the instrument for successful 10-color FCM. Systematic review of issues related to sampling, preparation, instrument settings, spillover and compensation matrix, reagent performance, and general principles of panel construction was performed. 10-color FCM enables for increased accuracy in cell subpopulation identification, the ability to obtain detailed information from blood specimens, improved laboratory efficiency, and the means to consistently detect major and rare cell populations. Careful attention to details of instrument and reagent performance allows for the development of panels suitable for screening of samples from healthy and diseased donors. The characteristics of this technique are particularly well suited for the analysis of broad human population cohorts and have the potential to reach the everyday practice in a standardized way for the clinical laboratory.

  14. Color functional images of the cerebral blood flow. [/sup 133/Xe

    Energy Technology Data Exchange (ETDEWEB)

    Toyama, H.; Iio, M.; Iisaka, J.; Chiba, K.; Yamada, H.; Matsui, K.; Hoshi, Y.; Fuse, M.

    1976-11-01

    Functional gamma imaging, in color, was established for regional cerebral blood flow (rCBF) using /sup 133/Xe. During 10 min after intracarotid injection of /sup 133/Xe in saline, 60 picture frames of the /sup 133/Xe clearance curve for the entire hemisphere were obtained. After nine-point smoothing, the rCBF for each of the 4,096 picture elements was calculated by two methods: the half-time method and the height-over-area method. Both the /sup 133/Xe clearance half-times and the calculated CBF values were displayed, using 13 steps of color, as functional CBF images of the brain. Images of peak count and total count were also displayed on the same frame of the color television. Forty-six studies, performed on 37 patients with various cerebral disorders, were divided into two types: diffuse and focal. In the diffuse type, a decrease in CBF was noted in cases of normal-pressure hydrocephalus; successful ventriculoperitoneal shunt operations were followed by recovery of CBF. Occlusion of the middle cerebral artery showed up as a wedge-shaped area of decreased CBF, even when the conventional brain scan looked normal. Increased perfusion to a tumor was frequently associated with decreased CBF in the rest of the lateral hemisphere; such a decrease could be improved by surgical removal of the tumor.

  15. Experimental and theoretical study of rapid flows of cohesionless granular materials down inclined chutes

    NARCIS (Netherlands)

    Kruyt, N.P.; Verel, W.J.Th.

    1992-01-01

    A theoretical and experimental study is performed of rapid, fully developed flows of cohesionless granular materials down inclined chutes with a rough base. Two flow types are studied in detail: (1) immature sliding flow, where a stagnant zone forms on the base of the chute, and (2) fully developed

  16. Coherent structure coloring: identification of coherent structures from sparse flow trajectories using graph theory

    Science.gov (United States)

    Schlueter, Kristy; Dabiri, John

    2016-11-01

    Coherent structure identification is important in many fluid dynamics applications, including transport phenomena in ocean flows and mixing and diffusion in turbulence. However, many of the techniques currently available for measuring such flows, including ocean drifter datasets and particle tracking velocimetry, only result in sparse velocity data. This is often insufficient for the use of current coherent structure detection algorithms based on analysis of the deformation gradient. Here, we present a frame-invariant method for detecting coherent structures from Lagrangian flow trajectories that can be sparse in number. The method, based on principles used in graph coloring algorithms, examines a measure of the kinematic dissimilarity of all pairs of flow trajectories, either measured experimentally, e.g. using particle tracking velocimetry; or numerically, by advecting fluid particles in the Eulerian velocity field. Coherence is assigned to groups of particles whose kinematics remain similar throughout the time interval for which trajectory data is available, regardless of their physical proximity to one another. Through the use of several analytical and experimental validation cases, this algorithm is shown to robustly detect coherent structures using significantly less flow data than is required by existing methods. This research was supported by the Department of Defense (DoD) through the National Defense Science & Engineering Graduate Fellowship (NDSEG) Program.

  17. COLORFUL-Circuit: a platform for rapid multigene assembly, delivery and expression in plants

    Directory of Open Access Journals (Sweden)

    Hassan eGhareeb

    2016-03-01

    Full Text Available Advancing basic and applied plant research requires the continuous innovative development of the available technology toolbox. Essential components of this toolbox are methods that simplify the assembly, delivery and expression of multiple transgenes of interest. To allow simultaneous and directional multigene assembly on the same plant transformation vector, several strategies based on overlapping sequences or restriction enzymes have recently been developed. However, the assembly of homologous and repetitive DNA sequences can be inefficient and the frequent occurrence of target sequences recognized by commonly used restriction enzymes can be a limiting factor. Here, we noted that recognition sites for the restriction enzyme SfiI are rarely occurring in plant genomes. This fact was exploited to establish a multigene assembly system called COLORFUL-Circuit. To this end, we developed a set of binary vectors which provide a flexible and cost efficient cloning platform. The gene expression cassettes in our system are flanked with unique SfiI sites, which allow simultaneous multi-gene cassette assembly in a hosting binary vector. We used COLORFUL-Circuit to transiently and stably express up to four fluorescent organelle markers in addition to a selectable marker and analyzed the impact of assembly design on coexpression efficiency. Finally, we demonstrate the utility of our optimized COLORFUL-Circuit system in an exemplary case study, in which we monitored simultaneously the subcellular behavior of multiple organelles in a biotrophic plant-microbe interaction by Confocal Laser Scanning Microscopy.

  18. PRELIMINARY APPLICATION OF COLOR DOPPLER FLOW IMAGING IN THE LOCALIZATION OF PARATHYROID ADENOMAS

    Institute of Scientific and Technical Information of China (English)

    张缙熙; 李建初

    1994-01-01

    From December 1991 to April 1993,we performed color Doppler flow imaging(CDFI) in 11 patients with parathyroid adenoma,and all cases were confirmed by toperation and pathology.In all the parathyroid adenomas,vessels were clearly revealed at the periphery of the upper pole and /or anterior periphery,where arterial signals were elicited.These arteries had branches into the adenomas and originated from inferior thyroid arteries on the same side in most cases.The internal flow signals were increased markedly as compared to normal thyroid,and high-velocity arterial signals were detected.Because of the thyroid's rich blood supply and landmark peripheral vessels.CDFI can distinguish parathyroid foci from thyroid nodules,lymph nodes,and normal tissues and provide a sound basis for the diagnosis of small parathyroid foci.

  19. Color Doppler flow imaging diagnosis and treatment selection for erectile dysfunction

    Institute of Scientific and Technical Information of China (English)

    XUAN Xu-jun; ZHANG Cai-xia; HUANG Jian; Rong Lu; SUN Peng; LIU Hai-nan

    2011-01-01

    Background Targeted therapy for erectile dysfunction (ED) involves fewer screening tests and provides a variety of treatment choices for patients.Although the advantage of targeted therapy in diagnosis and therapy for ED has been recognized,the rational mode for oriented ED therapy has not been established.This study aimed to investigate targeted diagnosis and therapy for ED.Methods A total of 198 patients with ED were included in the study.After intracavernosal vasoactive agent injection was given,color Doppler flow imaging was performed and penile rigidity was classified as Schramek grade 5 (10 minutes duration),grade 4 (10 minutes duration),grade 3 and grade 2,defining four patient groups as group Ⅴ (143 cases),group Ⅳ (23 cases),group Ⅲ (18 cases),and group Ⅱ (14 cases).Appropriate and acceptable treatment was recommended to patients according to erection grade.Results In 198 patients with ED,the peak systolic velocity,end diastolic velocity,and resistance index in the cavemosal artery and dorsal artery and the flow velocity in the deep dorsal vein were not significantly different before injection (P >0.05).After injection,peak systolic velocity,end diastolic velocity,and resistance index in the cavernosal artery were different among the four groups (P<0.05).Between each two groups,the difference in resistance index was significant (P <0.05).The statistical differences in other indexes were not significant (P >0.05).Selective targeted therapy based on erection grade by color Doppler flow imaging improved the clinical satisfaction rate to 91.91% (182/198).Conclusions Based on the routine diagnosis of ED,blood flow indexes in the cavernosal artery are measured by color Doppler flow imaging following minimally invasive intercavernosal injection,which is combined with the Schramek grade of erection.The most appropriate and acceptable treatment is recommended according to the different groups,which improves the clinical satisfaction of treatment for

  20. Fast color flow mode imaging using plane wave excitation and temporal encoding

    Science.gov (United States)

    Udesen, Jesper; Gran, Fredrik; Jensen, Jorgen A.

    2005-04-01

    In conventional ultrasound color flow mode imaging, a large number (~500) of pulses have to be emitted in order to form a complete velocity map. This lowers the frame-rate and temporal resolution. A method for color flow imaging in which a few (~10) pulses have to be emitted to form a complete velocity image is presented. The method is based on using a plane wave excitation with temporal encoding to compensate for the decreased SNR, resulting from the lack of focusing. The temporal encoding is done with a linear frequency modulated signal. To decrease lateral sidelobes, a Tukey window is used as apodization on the transmitting aperture. The data are beamformed along the direction of the flow, and the velocity is found by 1-D cross correlation of these data. First the method is evaluated in simulations using the Field II program. Secondly, the method is evaluated using the experimental scanner RASMUS and a 7 MHz linear array transducer, which scans a circulating flowrig. The velocity of the blood mimicking fluid in the flowrig is constant and parabolic, and the center of the scanned area is situated at a depth of 40 mm. A CFM image of the blood flow in the flowrig is estimated from two pulse emissions. At the axial center line of the CFM image, the velocity is estimated over the vessel with a mean relative standard deviation of 2.64% and a mean relative bias of 6.91%. At an axial line 5 mm to the right of the center of the CFM image, the velocity is estimated over the vessel with a relative standard deviation of 0.84% and a relative bias of 5.74%. Finally the method is tested on the common carotid artery of a healthy 33-year-old male.

  1. Therapeutic embolization of high-flow priapism 1 year follow up with color Doppler sonography

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Song, E-mail: zhaosong1984@QQ.com; Zhou, Jun, E-mail: 18740585@QQ.COM; Zhang, Yi-Fan, E-mail: XXXzyf2011@163.com; Zhang, Xiao-Long, E-mail: 87512377@QQ.COM; Long, Qing-Yun, E-mail: longqy2005@aliyun.com

    2013-12-01

    Objective: The aim of this study was to evaluate the use of color Doppler sonography (CDS) for the diagnosis of high-flow priapism and the treatment of cavernosal arterial fistula via super-selective arterial embolization. Methods and materials: We reviewed eight cases of high-flow priapism with cavernosal arterial fistula, from 2005 to 2011. All of the patients were diagnosed with a high-flow priapism and unilateral artery fistula via CDS. Conventional treatments for the eight cases were unsuccessful, and the patients were then treated through super-selective embolization. Diagnostic angiograms of the internal iliac artery showed a fistula on one side of the cavernosal artery, thus confirming the CDS images. We compared hemodynamic parameters including the peak systolic velocity, end diastolic velocity the resistance index of the pathological cavernosal artery and intracavernosal pressure in all patients before and after treatment using t-test. The efficacy of super-selective embolization and the erectile function of all patients were evaluated at a follow-up time of 12 months. Results: All patients were successfully treated and angiography showed that the fistulas disappeared after treatment. Additionally significant differences were found in the peak systolic velocity, the end diastolic velocity, the resistance index and intracavernosal pressure between pre-treatment and post-treatment (P < 0.05). At 5 days post-treatment, only one case relapses had occurred. Seven cases displayed restored erectile function and only one case exhibited erectile dysfunction. Conclusion: Color Doppler sonography is a highly sensitive method for the examination of high-flow priapism, and super-selective embolization is a safe and effective treatment for cavernosal arterial fistula.

  2. Assessment of a five-color flow cytometric assay for verifying automated white blood cell differentials

    Institute of Scientific and Technical Information of China (English)

    HUANG Chun-mei; YU Lian-hui; PU Cheng-wei; WANG Xin; WANG Geng; SHEN Li-song; WANG Jian-zhong

    2013-01-01

    Background White blood cell (WBC) counts and differentials performed using an automated cell counter typically require manual microscopic review.However,this last step is time consuming and requires experienced personnel.We evaluated the clinical efficiency of using flow cytometry (FCM) employing a six-antibody/five-color reagent for verifying automated WBC differentials.Methods A total of 56 apparently healthy samples were assessed using a five-color flow cytometer to verify the normal reference ranges of WBC differentials.WBC differentials of 622 samples were also determined using both a cell counter and FCM.These results were then confirmed using manual microscopic methods.Results The probabilities for all of the parameters of WBC differentials exceeded the corresponding normal reference ranges by no more than 7.5%.The resulting WBC differentials were well correlated between FCM and the cell counter (r >0.88,P <0.001),except in the case of basophils.Neutrophils,lymphocytes,and eosinophils were well correlated between FCM and standard microscopic cytology assessment (r >0.80,P <0.001).The sensitivities of FCM for identification of immature granulocytes and blast cells (72.03% and 22.22%,respectively) were higher than those of the cell counter method (44.92% and 11.11%,respectively).The specificities of FCM were all above 85%,substantially better than those of the cell counter method.Conclusion These five-color FCM assays could be applied to accurately verify abnormal results of automated assessment of WBC differentials.

  3. Update of Columbia River flow and temperature data measured at Priest Rapids Dam and Vernita Bridge

    Energy Technology Data Exchange (ETDEWEB)

    Whelan, G.; Newbill, C.A.

    1983-09-01

    Columbia River temperatures and flow rates are collected daily at Priest Rapids Dam and Vernita Bridge. These data are necessary for assessing trends or changes in river conditions downstream of Priest Rapids Dam. In order to analyze this data, Pacific Northwest Laboratory developed a computerized data base using existing US Geological Survey flow and temperature records at Priest Rapids Dam and Vernita Bridge. Daily-averaged temperature and daily flow information on the Columbia River just downstream of Priest Rapids Dam and upstream of river mile 380 were collected and stored in a data base. A newly developed computer model, COLSTAT (Columbia River Statistical Update), used the data base to statistically analyze temperature and flow conditions by computing the frequency of occurrence and duration of selected temperatures and flow rates for the Columbia River. Information regarding the data base is presented, as well as, a description of the COLSTAT model.

  4. The flow of two falling balls mixes rapidly

    Science.gov (United States)

    Bálint, Péter; Némedy Varga, András

    2016-09-01

    In this paper we study the system of two falling balls in continuous time. We model the system by a suspension flow over a two dimensional, hyperbolic base map. By detailed analysis of the geometry of the system we identify special periodic points and show that the ratio of certain periods in continuous time is Diophantine for almost every value of the mass parameter in an interval. Using results of Melbourne (2007 Trans. Am. Math. Soc. 359 2421-41) and our previous achievements (Bálint et al 2012 Chaos 22 026104) we conclude that for these values of the parameter the flow mixes faster than any polynomial. Even though the calculations are presented for the specific physical system, the method is quite general and can be applied to other suspension flows, too.

  5. Rapid color evolution in an aposematic species: a phylogenetic analysis of color variation in the strikingly polymorphic strawberry poison-dart frog.

    Science.gov (United States)

    Wang, Ian J; Shaffer, H Bradley

    2008-11-01

    Aposematism is one of the great mysteries of evolutionary biology. The evolution of aposematic coloration is poorly understood, but even less understood is the evolution of polymorphism in aposematic signals. Here, we use a phylogeographic approach to investigate the evolution of color polymorphism in Dendrobates pumilio, a well-known poison-dart frog (family Dendrobatidae), which displays perhaps the most striking color variation of any aposematic species. With over a dozen color morphs, ranging from bright red to dull green, D. pumilio provides an ideal opportunity to examine the evolution of color polymorphism and evolutionary shifts to cryptic coloration in an otherwise aposematic species. We constructed a phylogenetic tree for all D. pumilio color morphs from 3051bp of mtDNA sequence data, reconstructed ancestral states using parsimony and Bayesian methods, and tested the recovered tree against constraint trees using parametric bootstrapping to determine the number of changes to each color type. We find strong evidence for nearly maximal numbers of changes in all color traits, including five independent shifts to dull dorsal coloration. Our results indicate that shifts in coloration in aposematic species may occur more regularly than predicted and that convergence in coloration may indicate that similar forces are repeatedly driving these shifts.

  6. Rapid detection of fungal alpha-amylase in the work environment with a lateral flow immunoassay

    NARCIS (Netherlands)

    Bogdanovic, J.; Koets, M.; Sander, I.; Wouters, I.; Meijster, T.; Heederik, D.J.J.; Amerongen, van A.; Doekes, G.

    2006-01-01

    Background Occupational allergen exposure assessment usually requires airborne dust sampling at the worksite followed by dust extraction and enzyme immunoassay (EIA) analysis at the laboratory. Use of semiquantitative lateral flow immunoassays (LFIAs) may allow a more rapid detection procedure with

  7. Rapid Detection Method of Moldy Maize Kernels Based on Color Feature

    Directory of Open Access Journals (Sweden)

    Xuan Chu

    2014-05-01

    Full Text Available In order to find the moldy maize kernels quickly, a method based on machine vision was proposed in this paper. Firstly, images of maize kernels were taken by the moldy maize sorting equipment, and three parts of every kernel, that is, moldy plaques, healthy endosperm and healthy embryo, were selected from these images. Then a threshold was set in R channel by analyzing color features of those three parts in RGB model. In this method, moldy plaques can be identified roughly. After that the location of the moldy plaques on the kernels was studied, a circle, whose centre was approximately the centroid of a maize kernel and diameter was about the width of embryos, was set to exclude the interference caused by shadow. This method, with the accuracy of 92.1%, laid a good foundation for the further study of moldy maize sorting equipment.

  8. EVALUATION OF THE DIAGNOSTIC CRITERIA FOR THE LOCALIZATION OF ACQUIRED ARTERIOVENOUS FISTULAS BY COLOR DOPPLER FLOW IMAGING

    Institute of Scientific and Technical Information of China (English)

    李建初; 蔡胜; 姜玉新; 张缙熙; 王岩青

    2001-01-01

    Objective. To evaluate the diagnostic criteria for the localization of acquired arteriovenous fistulas (AVFs)by color Doppler flow imaging (CDFI) based on the features of their hemodynamic changes.Methods. The shape and hemodynamic changes of involved vessels which could be helpful to localize thesites of fistulas were studied according to the observation of 10 cases of acquired AVFs.Results. The s tes of the fistulas could be shown by two-dimensional ultrasonography and color flow imagingin 40% and 80% tases, respectively. In all cases, turbulent high-velocity flow was present at the sites of thefistulas, low resistant flow was present in the arteries proximal to the fistulas, and artery-like flow was detected inthe veins.Conclusion. C OFt was accurate for the localization of acquired AVFs, which were mainly localized by theirhemodynamic changes shown by pulse Doppler ultrasound.``

  9. Improving emergency department flow through Rapid Medical Evaluation unit.

    Science.gov (United States)

    Chartier, Lucas; Josephson, Timothy; Bates, Kathy; Kuipers, Meredith

    2015-01-01

    The Toronto Western Hospital is an academic hospital in Toronto, Canada, with an annual Emergency Department (ED) volume of 64,000 patients. Despite increases in patient volumes of almost six percent per annum over the last decade, there have been no commensurate increases in resources, infrastructure, and staffing. This has led to substantial increase in patient wait times, most specifically for those patients with lower acuity presentations. Despite requiring only minimal care, these patients contribute disproportionately to ED congestion, which can adversely impact resource utilization and quality of care for all patients. We undertook a retrospective evaluation of a quality improvement initiative aimed at improving wait times experienced by patients with lower acuity presentations. A rapid improvement event was organized by frontline workers to rapidly overhaul processes of care, leading to the creation of the Rapid Medical Evaluation (RME) unit - a new pathway of care for patients with lower acuity presentations. The RME unit was designed by re-purposing existing resources and re-assigning one physician and one nurse towards the specific care of these patients. We evaluated the performance of the RME unit through measurement of physician initial assessment (PIA) times and total length of stay (LOS) times for multiple groups of patients assigned to various ED care pathways, during three periods lasting three months each. Weekly measurements of mean and 90th percentile of PIA and LOS times showed special cause variation in all targeted patient groups. Of note, the patients seen in the RME unit saw their median PIA and LOS times decrease from 98min to 70min and from 165min to 130min, respectively, from baseline. Despite ever-growing numbers of patient visits, wait times for all patients with lower acuity presentations remained low, and wait times of patients with higher acuity presentations assigned to other ED care pathways were not adversely affected. By

  10. [Design Method Analysis and Performance Comparison of Wall Filter for Ultrasound Color Flow Imaging].

    Science.gov (United States)

    Wang, Lutao; Xiao, Jun; Chai, Hua

    2015-08-01

    The successful suppression of clutter arising from stationary or slowly moving tissue is one of the key issues in medical ultrasound color blood imaging. Remaining clutter may cause bias in the mean blood frequency estimation and results in a potentially misleading description of blood-flow. In this paper, based on the principle of general wall-filter, the design process of three classes of filters, infinitely impulse response with projection initialization (Prj-IIR), polynomials regression (Pol-Reg), and eigen-based filters are previewed and analyzed. The performance of the filters was assessed by calculating the bias and variance of a mean blood velocity using a standard autocorrelation estimator. Simulation results show that the performance of Pol-Reg filter is similar to Prj-IIR filters. Both of them can offer accurate estimation of mean blood flow speed under steady clutter conditions, and the clutter rejection ability can be enhanced by increasing the ensemble size of Doppler vector. Eigen-based filters can effectively remove the non-stationary clutter component, and further improve the estimation accuracy for low speed blood flow signals. There is also no significant increase in computation complexity for eigen-based filters when the ensemble size is less than 10.

  11. Eigen-based clutter filter design for ultrasound color flow imaging: a review.

    Science.gov (United States)

    Yu, Alfred; Lovstakken, Lasse

    2010-05-01

    Proper suppression of tissue clutter is a prerequisite for visualizing flow accurately in ultrasound color flow imaging. Among various clutter suppression methods, the eigen-based filter has shown potential because it can theoretically adapt its stopband to the actual clutter characteristics even when tissue motion is present. This paper presents a formative review on how eigen-based filters should be designed to improve their practical efficacy in adaptively suppressing clutter without affecting the blood flow echoes. Our review is centered around a comparative assessment of two eigen-filter design considerations: 1) eigen-component estimation approach (single-ensemble vs. multi-ensemble formulations), and 2) filter order selection mechanism (eigenvalue-based vs. frequencybased algorithms). To evaluate the practical efficacy of existing eigen-filter designs, we analyzed their clutter suppression level in two in vivo scenarios with substantial tissue motion (intra-operative coronary imaging and thyroid imaging). Our analysis shows that, as compared with polynomial regression filters (with or without instantaneous clutter downmixing), eigen-filters that use a frequency-based algorithm for filter order selection generally give Doppler power images with better contrast between blood and tissue regions. Results also suggest that both multi-ensemble and single-ensemble eigen-estimation approaches have their own advantages and weaknesses in different imaging scenarios. It may be beneficial to develop an algorithmic way of defining the eigen-filter formulation so that its performance advantages can be better realized.

  12. Elliptic flow from color-dipole orientation in p p and p A collisions

    Science.gov (United States)

    Iancu, Edmond; Rezaeian, Amir H.

    2017-05-01

    For ultrarelativistic proton-proton and proton-nucleus collisions, we perform an exploratory study of the contribution to the elliptic flow v2 coming from the orientation of the momentum of the produced particles with respect to the reaction plane. Via the color glass condensate factorization valid at high energies, this contribution is related to the orientation of a color dipole with respect to its impact parameter, which in turn probes the transverse inhomogeneity in the target. Using the McLerran-Venugopalan model (with impact-parameter dependence) as an effective description for the soft gluon distribution in the (proton or nuclear) target, we present a semianalytic calculation of the dipole-scattering amplitude, including its angular dependence. We find that the angular dependence is controlled by soft gluon exchanges and hence is genuinely nonperturbative. The effects of multiple scattering turn out to be essential (in particular, they change the sign of v2). We find that sizable values for v2, comparable to those observed in the LHC data and having a similar dependence upon the transverse momenta of the produced particles, can be easily generated via peripheral collisions. In particular, v2 develops a peak at a transverse momentum that scales with the saturation momentum in the target.

  13. Evaluation of retrobulbar blood flow in patients with age-related cataract; color Doppler ultrasonographic findings

    Directory of Open Access Journals (Sweden)

    Mohammadi A

    2011-10-01

    Full Text Available Afshin Mohammadi1, Nilofar Khorasani2, Farzad Moloudi2, Mohammad Ghasemi-rad31Department of Radiology, Urmia University of Medical Sciences, Urmia, Iran; 2Student Research Committee, Urmia University of Medical Sciences, Urmia, Iran; 3Genius and Talented Student Organization, Student Research Committee, Urmia University of Medical Sciences, Urmia, IranObjectives: Cataracts are the most common cause of blindness worldwide, with cataract surgery being the most common ophthalmic procedure. To our best knowledge, this is the first case-control study with a large number of participants to evaluate ocular blood flow in patients with cataracts.Materials and methods: Color Doppler and duplex sonography of the orbital vessels was performed in 224 eyes of 112 patients with known bilateral age-related cataracts and in 76 eyes of 38 healthy age- and sex-matched volunteers.Results: The mean ± (standard deviation [SD] of peak systolic velocity (PSV of the ophthalmic artery in patients with cataracts (34.59 ± 22.49 cm/second was significantly different to that in controls (52.11 ± 14.01 cm/second (P < 0.001. The mean ± SD PSV of the central retinal artery in patients with cataracts (15.31 ± 4.93 cm/second was significantly different to that in controls (9.61 ± 5.64 cm/second (P < 0.001.Conclusion: The mean PSV and resistive index (RI of the ophthalmic and central retinal arteries were lower in cataract patients when compared with normal subjects. This suggests that ocular hypoperfusion and changes in ocular hemodynamic may have a role in the formation of age-related cataracts.Keywords: retrobulbar blood flow, age-related, cataract, color Doppler ultrasonographic

  14. [Intracranial blood flow velocities evaluated by color Doppler (duplex) in preterm infants].

    Science.gov (United States)

    de Assis, Marcelo Cardoso; Machado, Helio Rubens

    2004-03-01

    In order to ascertain the blood flow velocities in the intracranial arteries we evaluated 73 preterm neonates during a period ranging from June 1994 to March 1999. These preterm infants were divided in two separate groups, 18 healthy and 55 with intracranial hemorrhage. They were subjected to sequential measurements of blood flow velocities in the intracranial arteries. The gestational age of the whole group varied from 28 to 36 weeks and birth weights between 720 and 2530 g. The diagnosis of the intracerebral hemorrhages in these preterm neonates were done using high resolution gray and color scale transfontanellar ultrasonography brain scans. The ultrasound evaluations were performed in the initial 3rd, 7th and 14th day of life. The 73 preterm infants were evaluated with sequential measurements of blood flow velocity in the intracranial arteries using the Doppler technique through the anterior fontanelle. Doppler evaluation of the cerebral vessels were performed on days 3, 7, 30 and 90 of life. These evaluations were performed in the six intracranial arteries, meaning: right and left anterior and middle cerebral arteries and right and left internal carotid arteries. Doppler recordings were made using Duplex Color-Doppler system, pulse echo probe of 3,5; 5,0 and 7,5 MHz. Measuring the blood flow velocity in the cerebral arteries we obtained a maximum systolic velocity and end diastolic velocity with a rate in meters per second (m/s) for each cardiac cycle. After obtaining these numerical values for these velocities we obtained the resistance index (RI) or Pourcelot index. In a progressive way as the resistance index (RI) values were being obtained in each stage of this study they were also being checked in the cerebral arteries of healthy preterm infants and infants with intracranial hemorrhages. We also analyzed in a comparative method the values of the resistive index between the two groups of preterm infants observing their behaviour. The results obtained when

  15. Simple and rapid preparation of red fluorescence and red color S. aureus derived nanobioparticles for pathogen detection.

    Science.gov (United States)

    Hu, Wei; Zhang, Yun; Yang, Hang; Yu, Junping; Wei, Hongping

    2015-08-01

    In this study, a simple and rapid method was developed to transform protein A producing Staphylococcus aureus cells into red color and red fluorescent nanobioparticles, which were homogeneous, dispersive and relatively stable with a uniform size of 800 nm. The method consists of reaction with a monotetrazolium redox dye at 25°C for 15 min and heat inactivation at 65°C for 30 min. This method provided the first S. aureus nanobioparticles with the dual property of red color and red fluorescence. Attributed to the IgG binding site known as protein A on their surface, the nanobioparticles could be used as vectors for immunoassays of many bacteria and viruses. Coagglutination test of Escherichia coli O157:H7 observed by naked eyes showed that the detection limitation of the nanobioprobes was 1∗10(6) CFU/ml, which was about 100 times more sensitive than the natural uncolored S. aureus bioprobes. Red fluorescence detection and analysis of the coagglutination product by a microplate reader lowered the detection limit to 2.5∗10(4) CFU/ml. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Impact of the new Beckman Coulter Cytomics FC 500 5-color flow cytometer on a regional flow cytometry clinical laboratory service.

    Science.gov (United States)

    Luider, J; Cyfra, M; Johnson, P; Auer, I

    2004-01-01

    Calgary Laboratory Services (CLS) in Alberta, Canada, is the regional reference laboratory providing flow cytometry services for southern Alberta and southeastern British Columbia. As a busy reference flow laboratory we provide flow cytometry immunophenotyping for investigation and diagnosis of acute and chronic leukemias, lymphomas, immunodeficiencies, neuroblastoma, platelet disorders, and interstitial lung disease (ILD). Because of increasing workload and the continual effort to improve the service to our health care providers, CLS invested in the new Beckman Coulter Cytomics FC 500 5-color flow cytometer. In addition to time and labor savings due to reduced maintenance and operating system design, this new flow cytometer automates many of the previous manual steps involved in quality control and flow cytometric analysis. It also incorporates 2 lasers and is capable of measuring 5-color antibody combinations in a single tube, enabling us to reduce the number of tubes and overall costs, giving us better gating options for minimal residual disease analysis. We present the first published evaluation, an assessment of the overall productivity and cost impact of the new state-of-the-art Cytomics FC 500 flow cytometer. Implementation of the Cytomics FC 500 has resulted in a 20% reduction in reagent costs and shorter turnaround time for analysis and diagnosis. This instrument has allowed us to reduce our acute leukemia panel from 17 to 13 tubes, our lymphoma panel from 13 to 7 tubes, and our ILD panel from 4 to 2 tubes. The availability of 2 lasers provides more flexibility in choosing antibodies and conjugates to customize immunophenotyping panels. It also allows us to use the DRAQ5 dye and simultaneously analyze the immunophenotype and DNA content of cells with very little compensation. Many of the arduous, time-consuming flow operator tasks often associated with previous generation flow cytometry instruments, such as color compensation, list mode analysis, sample

  17. A GPU-Parallelized Eigen-Based Clutter Filter Framework for Ultrasound Color Flow Imaging.

    Science.gov (United States)

    Chee, Adrian J Y; Yiu, Billy Y S; Yu, Alfred C H

    2017-01-01

    Eigen-filters with attenuation response adapted to clutter statistics in color flow imaging (CFI) have shown improved flow detection sensitivity in the presence of tissue motion. Nevertheless, its practical adoption in clinical use is not straightforward due to the high computational cost for solving eigendecompositions. Here, we provide a pedagogical description of how a real-time computing framework for eigen-based clutter filtering can be developed through a single-instruction, multiple data (SIMD) computing approach that can be implemented on a graphical processing unit (GPU). Emphasis is placed on the single-ensemble-based eigen-filtering approach (Hankel singular value decomposition), since it is algorithmically compatible with GPU-based SIMD computing. The key algebraic principles and the corresponding SIMD algorithm are explained, and annotations on how such algorithm can be rationally implemented on the GPU are presented. Real-time efficacy of our framework was experimentally investigated on a single GPU device (GTX Titan X), and the computing throughput for varying scan depths and slow-time ensemble lengths was studied. Using our eigen-processing framework, real-time video-range throughput (24 frames/s) can be attained for CFI frames with full view in azimuth direction (128 scanlines), up to a scan depth of 5 cm ( λ pixel axial spacing) for slow-time ensemble length of 16 samples. The corresponding CFI image frames, with respect to the ones derived from non-adaptive polynomial regression clutter filtering, yielded enhanced flow detection sensitivity in vivo, as demonstrated in a carotid imaging case example. These findings indicate that the GPU-enabled eigen-based clutter filtering can improve CFI flow detection performance in real time.

  18. Evidence for Rapid Redshift Evolution of Strong Cluster Cooling Flows

    CERN Document Server

    Samuele, R; Vikhlinin, A; Mullis, C R

    2011-01-01

    We present equivalent widths of the [OII] and Ha nebular emission lines for 77 brightest cluster galaxies (BCGs) selected from the 160 Square Degree $ROSAT$ X-ray survey. We find no [OII] or Ha emission stronger than -15 angstroms or -5 angstroms, respectively, in any BCG. The corresponding emission line luminosities lie below 6E40 erg/s, which is a factor of 30 below that of NGC1275 in the Perseus cluster. A comparison to the detection frequency of nebular emission in BCGs lying at redshifts above z = 0.35 drawn from the Brightest Cluster Survey (Crawford et al. 1999) indicates that we should have detected roughly one dozen emission-line galaxies, assuming the two surveys are selecting similar clusters in the X-ray luminosity range 10E42 erg/s to 10E45 erg/s. The absence of luminous nebular emission (ie., Perseus-like systems) in our sample is consistent with an increase in the number density of {\\it strong} cooling flow (cooling core) clusters between $\\rm z=0.5$ and today. The decline in their numbers at h...

  19. Comparison of vertebral artery velocity and flow volume measurements for diagnosis of vertebrobasilar insufficiency using color duplex sonography

    Energy Technology Data Exchange (ETDEWEB)

    Acar, Murat [Department of Radiology, Faculty of Medicine, Afyon Kocatepe University, Kirmizi Hastane, 03200 Afyon (Turkey)]. E-mail: drmacar@hotmail.com; Degirmenci, Bumin [Department of Radiology, Faculty of Medicine, Afyon Kocatepe University, Kirmizi Hastane, 03200 Afyon (Turkey); Yucel, Aylin [Department of Radiology, Faculty of Medicine, Afyon Kocatepe University, Kirmizi Hastane, 03200 Afyon (Turkey); Albayrak, Ramazan [Department of Radiology, Faculty of Medicine, Afyon Kocatepe University, Kirmizi Hastane, 03200 Afyon (Turkey); Haktanir, Alpay [Department of Radiology, Faculty of Medicine, Afyon Kocatepe University, Kirmizi Hastane, 03200 Afyon (Turkey); Yaman, Mehmet [Department of Neurology, Faculty of Medicine, Afyon Kocatepe University, 03200 Afyon (Turkey)

    2005-05-01

    Introduction: The aim of this study was to compare the measurements of vertebral artery (VA) systolic flow velocity and flow volume for diagnosis of vertebrobasilar insufficiency (VBI). Material and methods: We examined 96 patients who were referred for evaluation of VBI. Net vertebral artery flow volume and mean systolic flow velocity were determined by using color duplex sonography. We had grouped the patients into three according to VA flow volume: group 1 was consisted of patients with severely damped VA flow volume (lower than 120 mL/min), group 2 was consisted of patients with moderately damped VA flow volume (120-200 mL/min), group 3 was consisted of patients with normal VA flow volume (>200 mL/min). The mean systolic flow velocities in each group were compared by one-way ANOVA. Results: Mean VA systolic flow velocities of groups 1, 2 and 3 were 32 {+-} 12, 42 {+-} 10 and 46 {+-} 8 cm/s, respectively. Mean VA systolic flow velocity in group 1 was significantly lower than that of group 2 (P = 0.001). However, there were no significant differences between VA systolic flow velocities in groups 2 and 3 (P = 0.2). Conclusions: According to our findings, measurement of volume in addition to velocity is more valuable in detection of moderately damped VA flow volumes in diagnosis of VBI.

  20. Water velocity and the nature of critical flow in large rapids on the Colorado River, Utah

    Science.gov (United States)

    Magirl, C.S.; Gartner, J.W.; Smart, G.M.; Webb, R.H.

    2009-01-01

     Rapids are an integral part of bedrock-controlled rivers, influencing aquatic ecology, geomorphology, and recreational value. Flow measurements in rapids and high-gradient rivers are uncommon because of technical difficulties associated with positioning and operating sufficiently robust instruments. In the current study, detailed velocity, water surface, and bathymetric data were collected within rapids on the Colorado River in eastern Utah. With the water surface survey, it was found that shoreline-based water surface surveys may misrepresent the water surface slope along the centerline of a rapid. Flow velocities were measured with an ADCP and an electronic pitot-static tube. Integrating multiple measurements, the ADCP returned velocity data from the entire water column, even in sections of high water velocity. The maximum mean velocity measured with the ADCP was 3.7 m/s. The pitot-static tube, while capable of only point measurements, quantified velocity 0.39 m below the surface. The maximum mean velocity measured with the pitot tube was 5.2 m/s, with instantaneous velocities up to 6.5 m/s. Analysis of the data showed that flow was subcritical throughout all measured rapids with a maximum measured Froude number of 0.7 in the largest measured rapids. Froude numbers were highest at the entrance of a given rapid, then decreased below the first breaking waves. In the absence of detailed bathymetric and velocity data, the Froude number in the fastest-flowing section of a rapid was estimated from near-surface velocity and depth soundings alone.

  1. Role of color Doppler flow imaging in applicable anatomy of spleen vessels

    Institute of Scientific and Technical Information of China (English)

    Wei-Li Xu; Suo-Lin Li; Yan Wang; Meng Li; Ai-Guo Niu

    2009-01-01

    AIM: To explore the role of color Doppler flow imaging (CDFI) in visualization of spleen vessels and to define its value for spleen micro-invasive operation. METHODS: A total of 36 patients requiring laparoscopic splenectomy (LS) for various hematopathies and autoimmune diseases were randomly selected from April 2005 to May 2008. Anatomic types of spleen pedicle, adjacent relations between spleen vessels and pancreas, diameters of spleen artery and vein were detected and recorded by preoperative CDFI. Different operative procedures were performed according to different anatomic frameworks. The parameters were recorded by telerecording during LS and compared with those by preoperative CDFI using Chi-square test. RESULTS: Two anatomic types of spleen pedicle and four different adjacent relations between spleen vessels and pancreas were detected by CDFI. The diameters of spleen artery and vein detected by CDFI were 0.46 ± 0.09 cm and 0.85 ± 0.35 cm, respectively. There was no statistical difference between the parameters recorded by CDFI and by telerecording (χ2 = 0.250, 0.677, P > 0.05). LS was successfully performed following the anatomic information provided by preoperative CDFI.CONCLUSION: Different anatomic frameworks of spleen vessels can be provided by preoperative CDFI,which instructs micro-invasive operation of spleen and increase the safety of operation.

  2. Rapid quantification of live/dead lactic acid bacteria in probiotic products using high-sensitivity flow cytometry

    Science.gov (United States)

    He, Shengbin; Hong, Xinyi; Huang, Tianxun; Zhang, Wenqiang; Zhou, Yingxing; Wu, Lina; Yan, Xiaomei

    2017-06-01

    A laboratory-built high-sensitivity flow cytometer (HSFCM) was employed for the rapid and accurate detection of lactic acid bacteria (LAB) and their viability in probiotic products. LAB were stained with both the cell membrane-permeable SYTO 9 green-fluorescent nucleic acid stain and the red-fluorescent nucleic acid stain, propidium iodide, which penetrates only bacteria with compromised membranes. The side scatter and dual-color fluorescence signals of single bacteria were detected simultaneously by the HSFCM. Ultra-high temperature processing milk and skim milk spiked with Lactobacillus casei were used as the model systems for the optimization of sample pretreatment and staining. The viable LAB counts measured by the HSFCM were in good agreement with those of the plate count method, and the measured ratios between the live and dead LAB matched well with the theoretical ratios. The established method was successfully applied to the rapid quantification of live/dead LAB in yogurts and fermented milk beverages of different brands. Moreover, the concentration and viability status of LAB in ambient yogurt, a relatively new yet popular milk product in China, are also reported.

  3. Quantification of mitral valve regurgitation with color flow Doppler using baseline shift.

    Science.gov (United States)

    Heß, Hannah; Eibel, Sarah; Mukherjee, Chirojit; Kaisers, Udo X; Ender, Joerg

    2013-02-01

    Vena contracta width (VCW) and effective regurgitant orifice area (EROA) are well established methods for evaluating mitral regurgitation using transesophageal echocardiography (TEE). For color-flow Doppler (CF) measurements Nyquist limit of 50-60 cm/s is recommended. Aim of the study was to investigate the effectiveness of a baseline shift of the Nyquist limit for these measurements. After a comprehensive 2-dimensional (2D) TEE examination, the mitral regurgitation jet was acquired with a Nyquist limit of 50 cm/s (NL50) along with a baseline shift to 37.5 cm/s (NL37.5) using CF. Moreover a real time 3-dimensional (RT 3D) color complete volume dataset was stored with a Nyquist limit of 50 cm/s (NL50) and 37.5 cm/s (NL37.5). Vena contracta width (VCW) as well as proximal isovelocity surface area (PISA) derived EROA were measured based on 2D TEE and compared to RT 3D echo measurements for vena contracta area (VCA) using planimetry method. Correlation between VCA 3D NL50 and VCW NL50 was 0.29 (p < 0.05) compared to 0.6 (p < 0.05) using NL37.5. Correlation between VCA 3D NL50 and EROA 2D NL50 was 0.46 (p < 0.05) vs. 0.6 (p < 0.05) EROA 2D NL37.5. Correlation between VCA 3D NL37.5 and VCW NL50 was 0.45 (p < 0.05) compared to 0.65 (p < 0.05) using VCW NL37.5. Correlation between VCA 3D NL37.5 and EROA 2D NL50 was 0.41 (p < 0.05) vs. 0.53 (p < 0.05) using EROA 2D NL37.5. Baseline shift of the NL to 37.5 cm/s improves the correlation for VCW and EROA when compared to RT 3D NL50 planimetry of the vena contracta area. Baseline shift in RT 3D to a NL of 37.5 cm/s shows similar results like NL50.

  4. Delayed Effect of Blood-Flow-Restricted Resistance Training on Rapid Force Capacity

    DEFF Research Database (Denmark)

    Nielsen, Jakob Lindberg; Frandsen, Ulrik; Prokhorova, Tatyana

    2017-01-01

    PURPOSE: The aim of the present study was to investigate the effect and time course of high-frequent low-load resistance training with blood-flow restriction (BFR) on rapid force capacity (i.e. rate of torque development (RTD)). METHODS: Ten male subjects (22.8±2.3 years) performed four sets...... and rapid force capacity (e.g. RTD) as well as evoked twitch contractile parameters was assessed before (Pre) and 5 and 12 days after training (Post5, Post12). Muscle biopsies were obtained Pre, after 8 days (Mid8) and 3 and 10 days post training (Post3, Post10) to examine changes in myofiber area...... exercise performed with blood-flow restriction leads to marked increases in rapid force capacity (RTD). However, a general delayed adaptive response was observed for voluntary contractile parameters (including RTD) in parallel with a decline and subsequent recovery in evoked contractile properties...

  5. Rapid heat-flowing surveying of geothermal areas, utilizing individual snowfalls as calorimeters

    Science.gov (United States)

    White, Donald E.

    1969-01-01

    Local differences in rate of heat transfer in vapor and by conduction through the ground in hot spring areas are difficult and time-consuming to measure quantitatively. Individual heavy snowfalls provide a rapid low-cost means of measuring total heat flow from such ground. After a favorable snowfall (heavy, brief duration, little wind, air temperature near 0°C), contacts between snow-covered and snow-free ground are mapped on a suitable base. Each mapped contact, as time elapses after a specific snowfall, is a heat-flow contour representing a decreasing rate of flow. Calibration of each mapped contact or snow line is made possible by the fact that snow remains on insulated surfaces (such as the boardwalks of Yellowstone's thermal areas) long after it has melted on adjacent warm ground. Heat-flow contours mapped to date range from 450 to 5500 μcal/cm2 sec, or 300 to 3700 times the world average of conductive heat flow. The very high rates of heat flow (2000 to > 10,000 μcal/cm2 sec) are probably too high, and the lower heat flows determinable by the method (2 sec) may be too low. Values indicated by the method are, however, probably within a factor of 2 of the total conductive and convective heat flow. Thermal anomalies from infrared imagery are similar in shape to heat-flow contours of a test area near Old Faithful geyser. Snowfall calorimetry provides a rapid means for evaluating the imagery and computer-derived products of the infrared data in terms of heat flow.

  6. Factors influencing the structure and shape of stenotic and regurgitant jets: an in vitro investigation using Doppler color flow mapping and optical flow visualization.

    Science.gov (United States)

    Krabill, K A; Sung, H W; Tamura, T; Chung, K J; Yoganathan, A P; Sahn, D J

    1989-06-01

    To evaluate factors influencing the structure and shape of stenotic and regurgitant jets, Doppler color flow mapping and optical flow visualization studies were performed with use of a syringe model with a constant rate of ejection to simulate jets of valvular regurgitation and a pulsatile flow model of the right heart chambers to simulate jets of mild, moderate and severe valvular pulmonary stenosis. Ink-(0 to 40%) glycerol-water jets (viscosity 1 to 3.5 centiPoise) were produced by injecting the fluid at a constant rate into a 10 gallon rectangular reservoir of the same still fluid through 1.4 and 3.4 mm needles. The Doppler color flow scanners imaged the laminar jet length within 3 mm of actual jet length (2 to 6 cm) and the jet width within 2 to 3 mm of the actual jet width. Jet flows with Reynolds numbers ranging from 230 to 1,200 injected into still fluid yielded jet length/width ratios that decreased with increasing Reynolds numbers and leveled off to a length/width ratio of 5-6:1 at a Reynolds number near 600. When the fluid reservoir was swirled to better mimic the effect of flow entering the same cardiac chamber from a second source, the jets showed diminution of the jet length/width ratio and a clearly defined zone of turbulence. Studies of the pulsatile flow model were performed at cardiac outputs of 1 to 6 liters/min for the normal and each stenotic valve. Mild stenosis had an orifice area of 2.8 cm2, moderate stenosis an area of 1.0 cm2 and severe stenosis an area of 0.5 cm2. Laminar jet length represented the length of the total jet, which had a symmetric width and was measured from the valve opening to a region where the jet exhibited a spray effect. Laminar jet lengths (0.2 to 1.1 cm) were imaged by Doppler color flow mapping and optical visualization only in the moderate and severely stenotic valves and only at flows less than or equal to 3 liters/min (mean Reynolds numbers less than or equal to 3,470). Beyond this flow rate the jets exhibited a

  7. Duplex Color Doppler Evaluation of Retinal Arterial Blood Flow in Type 2 Diabetic Subjects without Retinopathy

    Directory of Open Access Journals (Sweden)

    Mashah Binte Amin

    2014-09-01

    Full Text Available Background: Diabetic retinopathy is a vascular disorder affecting the microvasculature of retina. It is caused by changes in the blood vessels of retina. If untreated, it may lead to blindness which is usually preventable if retinopathy is diagnosed early and treated promptly. In ophthalmology, color Doppler imaging is a new method that enables us to assess the orbital vasculature. It allows for simultaneous two dimensional anatomical and Doppler evaluations of hemodynamic characteristics of retinal artery. Objective: To observe the difference between Doppler flow velocity indices (peak systolic velocity, end diastolic velocity and resistive index of retinal artery in type 2 diabetic subjects without retinopathy and those of normal controls. Materials and Methods: This case-control study was carried out in the department of Radiology and Imaging, Bangladesh Institute of Research and Rehabilitation in Diabetes, Endocrine and Metabolic Disorders (BIRDEM in collaboration with Ophthalmology Outpatient Department, BIRDEM, Dhaka from July 2011 to June 2013. Eighty diabetic patients without retinopathy aged 27–68 years were enrolled as cases and age and sex matched 80 healthy subjects were selected as controls. Type 1 diabetic patients, type 2 diabetics with retinopathy, hypertensive and dyslipidemic subjects were excluded from the study. All the selected subjects underwent duplex Doppler ultrasonography of both eyes using 5 to 7.5 MHZ linear phase transducer. Duplex color Doppler findings including spectral analysis (PSV, EDV and RI were recorded. Unpaired t test was done to compare blood flow velocity indices of retinal artery in type 2 diabetic patients without retinopathy and that of healthy control subjects. p value <0.05 was considered as significant. Results: Majority (42.5% and 47.5% of subjects were in 4th decade of life in both groups with predominance of males. The mean duration of diabetes was 4.56 ± 2.1 years. Mean peak systolic

  8. In-vivo imaging of blood flow in human retinal vessels using color Doppler optical coherence tomography

    Science.gov (United States)

    Yazdanfar, Siavash; Rollins, Andrew M.; Izatt, Joseph A.

    1999-04-01

    Quantification of retinal blood flow may lead to a better understanding of the progression and treatment of several ocular disorders, including diabetic retinopathy, age- related macular degeneration, and glaucoma. Current techniques, such as fluorescein angiography and laser Doppler velocimetry are limited, failing to provide sufficient information to the clinician. Color Doppler optical coherence tomography (CDOCT) is a novel technique using coherent heterodyne detection for simultaneous cross- sectional imaging of tissue microstructure and blood flow. This technique is capable of high spatial and velocity resolution imaging in highly scattering media. We implemented CDOCT for retinal blood flow mapping in human subjects. No dilation of the pupil was necessary. CDOCT is demonstrated for determining bidirectional flow in sub- 100micrometers diameter vessels in the retina. Additionally, we calculated Doppler broadening using the variance of depth- resolved spectra to identify regions with large velocity gradients within the Xenopus heart. This technique may be useful in quantifying local tissue perfusion in highly vascular retinal tissue.

  9. Rapid antioxidant capacity screening in herbal extracts using a simple flow injection-spectrophotometric system.

    Science.gov (United States)

    Mrazek, Nookrai; Watla-iad, Kanchana; Deachathai, Suwanna; Suteerapataranon, Siripat

    2012-05-01

    A simple flow injection (FI)-spectrophotometric system for the screening of antioxidant capacity in herbal extracts was developed. The analysis was based on the color disappearance due to the scavenging of 2,2-diphenyl-1-picrylhydrazyl (DPPH) radical by antioxidant compounds. DPPH and ascorbic acid were used as reagent and antioxidant standard, respectively. Effects of the DPPH concentration, DPPH flow rate, and reaction coil length on sensitivity were studied. The optimized condition provided the linear range of 0.010-0.300mM ascorbic acid with less than 5%RSD(n=10). Detection limit and quantitation limit were 0.004 and 0.013mM, respectively. Comparison of antioxidant capacity in some herbal extracts determined by the FI system and a standard method was carried out and no significant difference was obtained.

  10. Use of flow cytometry for rapid and accurate enumeration of live pathogenic Leptospira strains.

    Science.gov (United States)

    Fontana, Célia; Crussard, Steve; Simon-Dufay, Nathalie; Pialot, Daniel; Bomchil, Natalia; Reyes, Jean

    2017-01-01

    Enumeration of Leptospira, the causative agent of leptospirosis, is arduous mainly because of its slow growth rate. Rapid and reliable tools for numbering leptospires are still lacking. The current standard for Leptospira cultures is the count on Petroff-Hausser chamber under dark-field microscopy, but this method remains time-consuming, requires well-trained operators and lacks reproducibility. Here we present the development of a flow-cytometry technique for counting leptospires. We showed that upon addition of fluorescent dyes, necessary to discriminate the bacterial population from debris, several live Leptospira strains could be enumerated at different physiologic states. Flow cytometry titers were highly correlated to counts with Petroff-Hausser chambers (R(2)>0.99). Advantages of flow cytometry lie in its rapidity, its reproducibility significantly higher than Petroff-Hausser method and its wide linearity range, from 10(4) to 10(8)leptospires/ml. Therefore, flow cytometry is a fast, reproducible and sensitive tool representing a promising technology to replace current enumeration techniques of Leptospira in culture. We were also able to enumerate Leptospira in artificially infected urine and blood with a sensitivity limit of 10(5)leptospires/ml and 10(6)leptospires/ml, respectively, demonstrating the feasibility to use flow cytometry as first-line tool for diagnosis or bacterial dissemination studies.

  11. False-color composite of Landsat data for the Death Valley regional ground-water flow system project, Nevada and California

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — The false-color composite image of the Death Valley regional ground-water flow system (DVRFS), an approximately 100,000 square-kilometer region of southern Nevada...

  12. False-color composite of Landsat data for the Death Valley regional ground-water flow system project, Nevada and California

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — The false-color composite image of the Death Valley regional ground-water flow system (DVRFS), an approximately 100,000 square-kilometer region of southern Nevada...

  13. Nutrients, Dissolved Organic Carbon, Color, and Disinfection Byproducts in Base Flow and Stormflow in Streams of the Croton Watershed, Westchester and Putnam Counties, New York, 2000-02

    Science.gov (United States)

    Heisig, Paul M.

    2009-01-01

    between these flow conditions. Organic nitrogen concentrations (calculated as the difference between concentrations of total dissolved N and of all other N species) was the dominant form of nitrogen in undeveloped and moderately to poorly drained subbasins. High TP concentrations in stormflows (800-1,750 ug/L) were associated with well drained and moderately drained residential subbasins with high- and medium-density housing and with the moderately drained golf-course subbasin. Areas with medium to high housing densities favor TP transport because they provide extensive impervious surfaces, storm sewers, and local relief, which together can rapidly route stormwater to streams. SRP concentrations were highest in the same types of subbasins as TP, but also in sewered residential and horse-farm subbasins. The ratio of SRP to TP was typically a smaller in stormflow than in base flow. Base-flow TP and SRP concentrations were highest during the warm-weather months (May to October). The highest nitrate concentrations (3.0-4.5 mg/L) were associated with the urban subbasin and the three well drained, high-density residential subbasins. The two moderately drained lake subbasins and the two poorly drained (colored-water wetland) subbasins had consistently low nitrate concentrations despite low and medium housing densities. Nitrate concentrations were generally highest during the winter months and lowest during the autumn leaf-fall period. Organic N concentrations were highest during the leaf-fall period. Dissolved Organic Carbon. DOC concentration was consistently highest in the two poorly drained (colored-water-wetland) subbasins and lowest in the well drained subbasins. Base-flow DOC concentration increased with decreasing drainage efficiency, except in the well drained sewered subbasin with high-density housing, where slightly elevated DOC concentrations throughout the year may indicate leakage from a nearby sewer main. Seasonal changes in stormflow DOC concentrat

  14. Experimental observations of flow instabilities and rapid mixing of two dissimilar viscoelastic liquids

    Directory of Open Access Journals (Sweden)

    Hiong Yap Gan

    2012-12-01

    Full Text Available Viscoelastically induced flow instabilities, via a simple planar microchannel, were previously used to produce rapid mixing of two dissimilar polymeric liquids (i.e. at least a hundredfold different in shear viscosity even at a small Reynolds number. The unique advantage of this mixing technology is that viscoelastic liquids are readily found in chemical and biological samples like organic and polymeric liquids, blood and crowded proteins samples; their viscoelastic properties could be exploited. As such, an understanding of the underlying interactions will be important especially in rapid microfluidic mixing involving multiple-stream flow of complex (viscoelastic fluids in biological assays. Here, we use the same planar device to experimentally show that the elasticity ratio (i.e. the ratio of stored elastic energy to be relaxed between two liquids indeed plays a crucial role in the entire flow kinematics and the enhanced mixing. We demonstrate here that the polymer stretching dynamics generated in the upstream converging flow and the polymer relaxation events occurring in the downstream channel are not exclusively responsible for the transverse flow mixing, but the elasticity ratio is also equally important. The role of elasticity ratio for transverse flow instability and the associated enhanced mixing were illustrated based on experimental observations. A new parameter Deratio = Deside / Demain (i.e. the ratio of the Deborah number (De of the sidestream to the mainstream liquids is introduced to correlate the magnitude of energy discontinuity between the two liquids. A new Deratio-Demain operating space diagram was constructed to present the observation of the effects of both elasticity and energy discontinuity in a compact manner, and for a general classification of the states of flow development.

  15. Rapid parallel flow cytometry assays of active GTPases using effector beads.

    Science.gov (United States)

    Buranda, Tione; BasuRay, Soumik; Swanson, Scarlett; Agola, Jacob; Bondu, Virginie; Wandinger-Ness, Angela

    2013-11-15

    We describe a rapid assay for measuring the cellular activity of small guanine triphosphatases (GTPases) in response to a specific stimulus. Effector-functionalized beads are used to quantify in parallel multiple GTP-bound GTPases in the same cell lysate by flow cytometry. In a biologically relevant example, five different Ras family GTPases are shown for the first time to be involved in a concerted signaling cascade downstream of receptor ligation by Sin Nombre hantavirus.

  16. High-flow-velocity and shear-rate imaging by use of color Doppler optical coherence tomography.

    Science.gov (United States)

    van Leeuwen, T G; Kulkarni, M D; Yazdanfar, S; Rollins, A M; Izatt, J A

    1999-11-15

    Color Doppler optical coherence tomography (CDOCT) is capable of precise velocity mapping in turbid media. Previous CDOCT systems based on the short-time Fourier transform have been limited to maximum flow velocities of the order of tens of millimeters per second. We describe a technique, based on interference signal demodulation at multiple frequencies, to extend the physiological relevance of CDOCT by increasing the dynamic range of measurable velocities to hundreds of millimeters per second. The physiologically important parameter of shear rate is also derived from CDOCT measurements. The measured flow-velocity profiles and shear-rate distributions correlate very well with theoretical predictions. The multiple demodulation technique, therefore, may be useful to monitor blood flow in vivo and to identify regions with high and low shear rates.

  17. Flow-Based Systems for Rapid and High-Precision Enzyme Kinetics Studies

    Directory of Open Access Journals (Sweden)

    Supaporn Kradtap Hartwell

    2012-01-01

    Full Text Available Enzyme kinetics studies normally focus on the initial rate of enzymatic reaction. However, the manual operation of steps of the conventional enzyme kinetics method has some drawbacks. Errors can result from the imprecise time control and time necessary for manual changing the reaction cuvettes into and out of the detector. By using the automatic flow-based analytical systems, enzyme kinetics studies can be carried out at real-time initial rate avoiding the potential errors inherent in manual operation. Flow-based systems have been developed to provide rapid, low-volume, and high-precision analyses that effectively replace the many tedious and high volume requirements of conventional wet chemistry analyses. This article presents various arrangements of flow-based techniques and their potential use in future enzyme kinetics applications.

  18. Transient Flow in Rapidly Filling Air-Entrapped Pipelines with Moving Boundaries

    Institute of Scientific and Technical Information of China (English)

    ZHANG Yongliang; K. Vairavamoorthy

    2006-01-01

    A mathematical model is presented for transient flow in a rapidly filling pipeline with an entrapped air pocket. The influence of transient shear stress between the pipe wall and the flowing fluid is taken into account. A coordinate transformation technique is employed to generate adaptive moving meshes for the multiphase flow system as images of the time-independent computational meshes in auxiliary domains. The method of characteristics is used to reduce the coupled nonlinear hyperbolic partial differential equations governing the motion of the filling fluid, entrapped air, and blocking fluid to ordinary differential equations.Numerical solution of resulting equations shows that the transient shear stresses have only a small damping effect on the pressure fluctuations. The peak pressure in the entrapped air pocket decreases significantly with increasing initial entrapped air volume, but decreases slightly with increasing initial entrapped air pressure.

  19. Developmental validation of a novel lateral flow strip test for rapid identification of human blood (Rapid Stain Identification--Blood).

    Science.gov (United States)

    Schweers, Brett A; Old, Jennifer; Boonlayangoor, P W; Reich, Karl A

    2008-06-01

    Human blood is the body fluid most commonly encountered at crime scenes, and blood detection may aid investigators in reconstructing what occurred during a crime. In addition, blood detection can help determine which items of evidence should be processed for DNA-STR testing. Unfortunately, many common substances can cause red-brown stains that resemble blood. Furthermore, many current human blood detection methods are presumptive and prone to false positive results. Here, the developmental validation of a new blood identification test, Rapid Stain Identification--Blood (RSID--Blood), is described. RSID--Blood utilizes two anti-glycophorin A (red blood cell membrane specific protein) monoclonal antibodies in a lateral flow strip test format to detect human blood. We present evidence demonstrating that this test is accurate, reproducible, easy to use, and highly specific for human blood. Importantly, RSID--Blood does not cross-react with ferret, skunk, or primate blood and exhibits no high-dose hook effect. Also, we describe studies on the sensitivity, body fluid specificity, and species specificity of RSID--Blood. In addition, we show that the test can detect blood from a variety of forensic exhibits prior to processing for DNA-STR analysis. In conclusion, we suggest that RSID--Blood is effective and useful for the detection of human blood on forensic exhibits, and offers improved blood detection when compared to other currently used methods.

  20. The application of color Doppler flow imaging in the diagnosis and therapeutic effect evaluation of erectile dysfunction

    Directory of Open Access Journals (Sweden)

    Xu-Jun Xuan

    2016-01-01

    Full Text Available We aim to investigate the correlations between hemodynamic parameters, penile rigidity grading, and the therapeutic effects of phosphodiesterase type 5 inhibitors using color Doppler flow imaging after intracavernosal injection in patients with erectile dysfunction. This study involved 164 patients. After intracavernosal injection with a mixture of papaverine (60 mg, prostaglandin E 1 (10 mg, and lidocaine (2%, 0.5-1 ml, the penile vessels were assessed using color Doppler flow imaging. Penile rigidity was classified based on the Erection Hardness Score system as Grades 4, 3, 2 or 1 (corresponding to Schramek Grades V to II. Then, the patients were given oral sildenafil (50-100 mg and scored according to the International Index of Erectile Function (IIEF-5 questionnaire. The number of patients with penile rigidities of Schramek Grades II to V was 14, 18, 21, and 111, respectively. The IIEF-5 score was positively correlated with the refilling index of the penile cavernosal artery (r = 0.79, P< 0.05, the peak systolic velocity (r = 0.45, P< 0.05, and penile rigidity (r = 0.75, P< 0.05, and was negatively correlated with the end diastolic velocity (r = −0.74, P< 0.05. For patients with erectile dysfunction, both the IIEF-5 score after sildenafil administration, which is correlated with penile rigidity, and the hemodynamic parameters detected using color Doppler flow imaging may predict the effects of phosphodiesterase type 5 inhibitor treatment and could provide a reasonable model for the targeted-treatment of erectile dysfunction.

  1. Role of Color Flow Ultrasound in Detection of Deep Venous Thrombosis

    Science.gov (United States)

    Mohammed, Shelan Hakeem; AL-Najjar, Salwa A.

    2016-01-01

    Background: Deep vein thrombosis (DVT) of lower limbs is one of the most causes for the majority of death caused by pulmonary embolism. Many medical and surgical disorders are complicated by DVT. Most venous thrombi are clinically silent. B-mode and color Doppler imaging is needed for early diagnosis of DVT to prevent complications and squeal of…

  2. Rapid determination of tritium in groundwater. Colour and chemical quenching studies - Rapid determination of tritium in groundwater. Color and chemical quenching study

    Energy Technology Data Exchange (ETDEWEB)

    Fons, Jordi; Diaz, Vladimir; Badia, Andrea; Tent-Petrus, Joana; Llaurado, Montserrat [Laboratori de Radiologia Ambiental, University of Barcelona, Marti i Franques 1-11 3th floor, Barcelona (Spain)

    2014-07-01

    The determination of tritium in natural waters is useful in a wide range of environmental studies such as aquifer dating. Furthermore, tritiated water is used as a substance to trace groundwater flow systems, as well as in lab or in-situ studies of sorption and diffusion of water in clays or soils. Tritium has also an important interest for human and environmental health. For this reason it is included as a parameter in international legislation on the quality of drinking water [Council Directive 98/83/EC]. Tritium determination is performed using liquid scintillation counting. Do to the fact that tritium is a low energy beta emitter, its measurement is high greatly affected by quenching. Quenching in groundwater samples may result from a wide variety of components in a sample. To avoid it, it is usual to determine tritium applying a previous distillation step but, when rapid measurement is needed, a direct method is necessary and may leave quenching agents that interfere with the measurement. In this study quench effects in tritium determination are examined in order to correct the direct measurements. To fulfil this aim, different types of quenchers had been studied. Inorganic coloured solutions, organic inks, uncoloured organic substances and acids were used as quenching agents in vials with an approximately 30 Bq of {sup 3}H activity. The measurements were performed with Ultima Gold AB as a cocktail in a Wallac Quantulus'T'M 1220 counter. Counting efficiency was related to the SQP[E] quenching parameter for each type of quenching agent. In order to validate the usefulness of these quenching curves, coloured water samples from acid metalliferous drainage collected near Barcelona were spiked with a known amount of tritium. Determination was carried out by liquid scintillation counting applying the efficiency obtained with the quenching curve for the SQP[E] for each sample. These results are in complete accordance with both the amount of tritium added

  3. Color identification testing device

    Science.gov (United States)

    Brawner, E. L.; Martin, R.; Pate, W.

    1970-01-01

    Testing device, which determines ability of a technician to identify color-coded electric wires, is superior to standard color blindness tests. It tests speed of wire selection, detects partial color blindness, allows rapid testing, and may be administered by a color blind person.

  4. Water Quality and Environmental Flow Management in Rapidly Urbanizing Shenzhen Estuary Area, China

    Science.gov (United States)

    Qin, H.; Su, Q.

    2011-12-01

    Shenzhen estuary is located in a rapidly urbanizing coastal region of Southeast China, and forms the administrative border between mainland China and Hong Kong. It receives the waters of the Shenzhen River, where it enters the Deep Bay. The estuary has great ecological importance with the internationally recognized mangrove wetlands, which provides a habitat for some rare and endangered waterfowl and migratory birds.Water quality in the esturay has deteriorated not only due to increasing wastewater discharges from domestic and industrial sources, but also as a consequence of decreasing base environmental flow during rapid urbanization in the Shenzhen River catchment since 1980s. Measures to improve water quality of the estuary include not only reducing pollutant inputs by intercepting wastewater, but also increasing environmental flow by reusing reclaimed wastewater or withdrawing nearshore seawater into the river. However, salinity alternation due to flow increase is deemed to have impacts on the mangrove wetland ecosystem. In this paper, Environmental Fluid Dynamics Code (EFDC) is used to simulate hydrodynamics, salinity, and water quality condition in the Shenzhen estuary. After calibration and validation, the model is used to evaluate effects of various control measures on water quality improvement and salinity alteration in the estuary. The results indicate that implementing different measures independently does not reach the goals of water quality improvement; furthermore, increasing environmental flow by importing nearshore seawater may greatly increase the salinity in the Shenzhen River, destroy the fresh ecosystem of the river and have non-negligible impacts on the mangrove wetland ecosystem. Based on the effectiveness and impacts of the measures, an integrated measure, which combine pollutant loads reduction and environmental flow increase by reusing reclaimed wastewater, is proposed to achieve water environmental sustainability in the study area.

  5. Rapid Determination of Optimal Conditions in a Continuous Flow Reactor Using Process Analytical Technology

    Directory of Open Access Journals (Sweden)

    Michael F. Roberto

    2013-12-01

    Full Text Available Continuous flow reactors (CFRs are an emerging technology that offer several advantages over traditional batch synthesis methods, including more efficient mixing schemes, rapid heat transfer, and increased user safety. Of particular interest to the specialty chemical and pharmaceutical manufacturing industries is the significantly improved reliability and product reproducibility over time. CFR reproducibility can be attributed to the reactors achieving and maintaining a steady state once all physical and chemical conditions have stabilized. This work describes the implementation of a smart CFR with univariate physical and multivariate chemical monitoring that allows for rapid determination of steady state, requiring less than one minute. Additionally, the use of process analytical technology further enabled a significant reduction in the time and cost associated with offline validation methods. The technology implemented for this study is chemistry and hardware agnostic, making this approach a viable means of optimizing the conditions of any CFR.

  6. Dye Tracer Technique and Color Image Analysis For Describing Saturation State and 3d Axi-symmetrical Flow Pattern

    Science.gov (United States)

    Abriak, N. E.; Gandola, F.; Haverkamp, R.

    Dye tracer techniques have been widely used for visualising water flow pattern in soils and particularly, for determining the volumetric water content in a one dimensional and two dimensional laboratory experiments. The present study deals a 3 dimensional laboratory experiment (axi-symmetrical condition) using color visualisation technique and the image analysis technique for determining the spatial distribution of the water content. The infiltration of a dye (fluorescein) mixed with water is achieved under ax- isymmetrical condition in a Plexiglas tank (50t'50t'60cm) filled with a low saturated sand. Both infiltration and drainage processes are visualised under blue light condi- tion and recorded on videotape. The image analysis technique used for determining the saturation state is based on the use of a limited colors palette which allows to quan- tify the evolution of the saturation state in the sand. Simultaneously, nine tensiometers connected to a data acquisition system, are used to determine the negative water pres- sure in the sand. The measurement of the succion values confirms the existence of a second water wetting front (after the dye flow) due to the initial mobile water content in the sand.

  7. Smartphone-Based Dual-Modality Imaging System for Quantitative Detection of Color or Fluorescent Lateral Flow Immunochromatographic Strips

    Science.gov (United States)

    Hou, Yafei; Wang, Kan; Xiao, Kun; Qin, Weijian; Lu, Wenting; Tao, Wei; Cui, Daxiang

    2017-04-01

    Nowadays, lateral flow immunochromatographic assays are increasingly popular as a diagnostic tool for point-of-care (POC) test based on their simplicity, specificity, and sensitivity. Hence, quantitative detection and pluralistic popular application are urgently needed in medical examination. In this study, a smartphone-based dual-modality imaging system was developed for quantitative detection of color or fluorescent lateral flow test strips, which can be operated anywhere at any time. In this system, the white and ultra-violet (UV) light of optical device was designed, which was tunable with different strips, and the Sobel operator algorithm was used in the software, which could enhance the identification ability to recognize the test area from the background boundary information. Moreover, this technology based on extraction of the components from RGB format (red, green, and blue) of color strips or only red format of the fluorescent strips can obviously improve the high-signal intensity and sensitivity. Fifty samples were used to evaluate the accuracy of this system, and the ideal detection limit was calculated separately from detection of human chorionic gonadotropin (HCG) and carcinoembryonic antigen (CEA). The results indicated that smartphone-controlled dual-modality imaging system could provide various POC diagnoses, which becomes a potential technology for developing the next-generation of portable system in the near future.

  8. Rapid identification of Yersinia pestis and Brucella melitensis by chip-based continuous flow PCR

    Science.gov (United States)

    Dietzsch, Michael; Hlawatsch, Nadine; Melzer, Falk; Tomaso, Herbert; Gärtner, Claudia; Neubauer, Heinrich

    2012-06-01

    To combat the threat of biological agents like Yersinia pestis and Brucella melitensis in bioterroristic scenarios requires fast, easy-to-use and safe identification systems. In this study we describe a system for rapid amplification of specific genetic markers for the identification of Yersinia pestis and Brucella melitensis. Using chip based PCR and continuous flow technology we were able to amplify the targets simultaneously with a 2-step reaction profile within 20 minutes. The subsequent analysis of amplified fragments by standard gel electrophoresis requires another 45 minutes. We were able to detect both pathogens within 75 minutes being much faster than most other nucleic acid amplification technologies.

  9. Multiscale modeling of rapid granular flow with a hybrid discrete-continuum method

    CERN Document Server

    Chen, Xizhong; Li, Jinghai

    2015-01-01

    Both discrete and continuum models have been widely used to study rapid granular flow, discrete model is accurate but computationally expensive, whereas continuum model is computationally efficient but its accuracy is doubtful in many situations. Here we propose a hybrid discrete-continuum method to profit from the merits but discard the drawbacks of both discrete and continuum models. Continuum model is used in the regions where it is valid and discrete model is used in the regions where continuum description fails, they are coupled via dynamical exchange of parameters in the overlap regions. Simulation of granular channel flow demonstrates that the proposed hybrid discrete-continuum method is nearly as accurate as discrete model, with much less computational cost.

  10. Minimal residual disease monitoring by 8-color flow cytometry in mantle cell lymphoma: an EU-MCL and LYSA study

    Science.gov (United States)

    Cheminant, Morgane; Derrieux, Coralie; Touzart, Aurore; Schmit, Stéphanie; Grenier, Adrien; Trinquand, Amélie; Delfau-Larue, Marie-Hélène; Lhermitte, Ludovic; Thieblemont, Catherine; Ribrag, Vincent; Cheze, Stéphane; Sanhes, Laurence; Jardin, Fabrice; Lefrère, François; Delarue, Richard; Hoster, Eva; Dreyling, Martin; Asnafi, Vahid; Hermine, Olivier; Macintyre, Elizabeth

    2016-01-01

    Quantification of minimal residual disease may guide therapeutic strategies in mantle cell lymphoma. While multiparameter flow cytometry is used for diagnosis, the gold standard method for minimal residual disease analysis is real-time quantitative polymerase chain reaction (RQ-PCR). In this European Mantle Cell Lymphoma network (EU-MCL) pilot study, we compared flow cytometry with RQ-PCR for minimal residual disease detection. Of 113 patients with at least one minimal residual disease sample, RQ-PCR was applicable in 97 (86%). A total of 284 minimal residual disease samples from 61 patients were analyzed in parallel by flow cytometry and RQ-PCR. A single, 8-color, 10-antibody flow cytometry tube allowed specific minimal residual disease assessment in all patients, with a robust sensitivity of 0.01%. Using this cut-off level, the true-positive-rate of flow cytometry with respect to RQ-PCR was 80%, whereas the true-negative-rate was 92%. As expected, RQ-PCR frequently detected positivity below this 0.01% threshold, which is insufficiently sensitive for prognostic evaluation and would ideally be replaced with robust quantification down to a 0.001% (10-5) threshold. In 10 relapsing patients, the transition from negative to positive by RQ-PCR (median 22.5 months before relapse) nearly always preceded transition by flow cytometry (4.5 months), but transition to RQ-PCR positivity above 0.01% (5 months) was simultaneous. Pre-emptive rituximab treatment of 2 patients at minimal residual disease relapse allowed re-establishment of molecular and phenotypic complete remission. Flow cytometry minimal residual disease is a complementary approach to RQ-PCR and a promising tool in individual mantle cell lymphoma therapeutic management. PMID:26703963

  11. The Clustering Instability in Rapid Granular and Gas-Solid Flows

    Science.gov (United States)

    Fullmer, William D.; Hrenya, Christine M.

    2017-01-01

    Flows of solid particles are known to exhibit a clustering instability—dynamic microstructures characterized by a dense region of highly concentrated particles surrounded by a dilute region with relatively few particles—that has no counterpart in molecular fluids. Clustering is pervasive in rapid flows. Its presence impacts momentum, heat, and mass transfer, analogous to how turbulence affects single-phase flows. Yet predicting clustering is challenging, again analogous to the prediction of turbulent flows. In this review, we focus on three key areas: (a) state-of-the-art mathematical tools used to study clustering, with an emphasis on kinetic theory–based continuum models, which are critical to the prediction of the larger systems found in nature and industry, (b) mechanisms that give rise to clustering, most of which are explained via linear stability analyses of kinetic theory–based models, and (c) a critical review of validation studies of kinetic theory–based models to highlight the accuracies and limitations of such theories.

  12. A novel, rapid method to quantify intraplatelet calcium dynamics by ratiometric flow cytometry.

    Directory of Open Access Journals (Sweden)

    Alice Assinger

    Full Text Available Cytosolic free calcium ions represent important second-messengers in platelets. Therefore, quantitative measurement of intraplatelet calcium provides a popular and very sensitive tool to evaluate platelet activation and reactivity. Current protocols for determination of intracellular calcium concentrations in platelets have a number of limitations. Cuvette-based methods do not allow measurement of calcium flux in complex systems, such as whole blood, and therefore require isolation steps that potentially interfere with platelet activation. Flow cytometry has the potential to overcome this limitation, but to date the application of calibrated, quantitative readout of calcium kinetics has only been described for Indo-1. As excitation of Indo-1 requires a laser in the ultraviolet range, such measurements cannot be performed with a standard flow cytometer. Here, we describe a novel, rapid calibration method for ratiometric calcium measurement in platelets using both Ar(+-laser excited fluorescence dyes Fluo-4 and Fura Red. We provide appropriate equations that allow rapid quantification of intraplatelet calcium fluxes by measurement of only two standardisation buffers. We demonstrate that this method allows quantitative calcium measurement in platelet rich plasma as well as in whole blood. Further, we show that this method prevents artefacts due to platelet aggregate formation and is therefore an ideal tool to determine basal and agonist induced calcium kinetics.

  13. Rapid visible color change and physical swelling during water exposure in triethanolamine-metalcone films formed by molecular layer deposition

    Energy Technology Data Exchange (ETDEWEB)

    Lemaire, Paul C.; Oldham, Christopher J.; Parsons, Gregory N., E-mail: gnp@ncsu.edu [Department of Chemical and Biomolecular Engineering, North Carolina State University, Raleigh, North Carolina 27695 (United States)

    2016-01-15

    Molecular layer deposition (MLD) of “metalcones,” including alucone, zincone, titanicone, and others, involves self-limiting half-reactions between organic and organometallic (or metal-halide) reactants. Studies have typically focused on metal precursors reacting with ethylene glycol or glycerol to form the films' polymeric O-M-O-(CH{sub x}){sub y}-O-M-O repeat units. The authors report new MLD materials that incorporate tertiary amine groups into the organic linkage. Specifically, reacting triethanolamine (TEA) with either trimethylaluminum or titanium tetrachloride produces TEA-alucone (Al-TEA) and TEA-titanicone (Ti-TEA), respectively, and the amine group leads to unique physical and optical properties. Fourier-transform infrared (FTIR) analysis confirms that the films have prominent C-H, C-N, and M-O-C peaks, consistent with the expected bond structure. When exposed to vapors, including water, alcohol, or ammonia, the Ti-TEA films changed their visible color within minutes and increased physical thickness by >35%. The Al-TEA showed significantly less response. X-ray photoelectron spectroscopy and FTIR suggest that HCl generated during MLD coordinates to the amine forming a quaternary ammonium salt that readily binds adsorbates via hydrogen bonding. The visible color change is reversible, and ellipsometry confirms that the color change results from vapor absorption. The unique absorptive and color-changing properties of the TEA-metalcone films point to new possible applications for MLD materials in filtration, chemical absorption, and multifunctional chemical separations/sensing device systems.

  14. Rapid detection of Bacillus anthracis by γ phage amplification and lateral flow immunochromatography.

    Science.gov (United States)

    Cox, Christopher R; Jensen, Kirk R; Mondesire, Roy R; Voorhees, Kent J

    2015-11-01

    New, rapid point-of-need diagnostic methods for Bacillus anthracis detection can enhance civil and military responses to accidental or deliberate dispersal of anthrax as a biological weapon. Current laboratory-based methods for clinical identification of B. anthracis require 12 to 120h, and are confirmed by plaque assay using the well-characterized γ typing phage, which requires an additional minimum of 24h for bacterial culture. To reduce testing time, the natural specificity of γ phage amplification was investigated in combination with lateral flow immunochromatography (LFI) for rapid, point-of-need B. anthracis detection. Phage-based LFI detection of B. anthracis Sterne was validated over a range of bacterial and phage concentrations with optimal detection achieved in as little as 2h from the onset of amplification with a threshold sensitivity of 2.5×10(4)cfu/mL. The novel use of γ phage amplification detected with a simple, inexpensive LFI assay provides a rapid, sensitive, highly accurate, and field-deployable method for diagnostic ID of B. anthracis in a fraction of the time required by conventional techniques, and without the need for extensive laboratory culture.

  15. Determination of rapid chlorination rate constants by a stopped-flow spectrophotometric competition kinetics method.

    Science.gov (United States)

    Song, Dean; Liu, Huijuan; Qiang, Zhimin; Qu, Jiuhui

    2014-05-15

    Free chlorine is extensively used for water and wastewater disinfection nowadays. However, it still remains a big challenge to determine the rate constants of rapid chlorination reactions although competition kinetics and stopped-flow spectrophotometric (SFS) methods have been employed individually to investigate fast reaction kinetics. In this work, we proposed an SFS competition kinetics method to determine the rapid chlorination rate constants by using a common colorimetric reagent, N,N-diethyl-p-phenylenediamine (DPD), as a reference probe. A kinetic equation was first derived to estimate the reaction rate constant of DPD towards chlorine under a given pH and temperature condition. Then, on that basis, an SFS competition kinetics method was proposed to determine directly the chlorination rate constants of several representative compounds including tetracycline, ammonia, and four α-amino acids. Although Cl2O is more reactive than HOCl, its contribution to the overall chlorination kinetics of the test compounds could be neglected in this study. Finally, the developed method was validated through comparing the experimentally measured chlorination rate constants of the selected compounds with those obtained or calculated from literature and analyzing with Taft's correlation as well. This study demonstrates that the SFS competition kinetics method can measure the chlorination rate constants of a test compound rapidly and accurately.

  16. Streamwise-body-force-model for rapid simulation combining internal and external flow fields

    Directory of Open Access Journals (Sweden)

    Cui Rong

    2016-10-01

    Full Text Available A streamwise-body-force-model (SBFM is developed and applied in the overall flow simulation for the distributed propulsion system, combining internal and external flow fields. In view of axial stage effects, fan or compressor effects could be simplified as body forces along the streamline. These body forces which are functions of local parameters could be added as source terms in Navier-Stokes equations to replace solid boundary conditions of blades and hubs. The validation of SBFM with uniform inlet and distortion inlet of compressors shows that pressure performance characteristics agree well with experimental data. A three-dimensional simulation of the integration configuration, via a blended wing body aircraft with a distributed propulsion system using the SBFM, has been completed. Lift coefficient and drag coefficient agree well with wind tunnel test results. Results show that to reach the goal of rapid integrated simulation combining internal and external flow fields, the computational fluid dynamics method based on SBFM is reasonable.

  17. Rapid detection of genetically modified organisms on a continuous-flow polymerase chain reaction microfluidics.

    Science.gov (United States)

    Li, Yuyuan; Xing, Da; Zhang, Chunsun

    2009-02-01

    The ability to perform DNA amplification on a microfluidic device is very appealing. In this study, a compact continuous-flow polymerase chain reaction (PCR) microfluidics was developed for rapid analysis of genetically modified organisms (GMOs) in genetically modified soybeans. The device consists of three pieces of copper and a transparent polytetrafluoroethylene capillary tube embedded in the spiral channel fabricated on the copper. On this device, the P35S and Tnos sequences were successfully amplified within 9min, and the limit of detection of the DNA sample was estimated to be 0.005 ng microl(-1). Furthermore, a duplex continuous-flow PCR was also reported for the detection of the P35S and Tnos sequences in GMOs simultaneously. This method was coupled with the intercalating dye SYBR Green I and the melting curve analysis of the amplified products. Using this method, temperature differences were identified by the specific melting temperature values of two sequences, and the limit of detection of the DNA sample was assessed to be 0.01 ng microl(-1). Therefore, our results demonstrated that the continuous-flow PCR assay could discriminate the GMOs in a cost-saving and less time-consuming way.

  18. Field-Usable Lateral Flow Immunoassay for the Rapid Detection of White Spot Syndrome Virus (WSSV)

    Science.gov (United States)

    Kulabhusan, Prabir Kumar; Rajwade, Jyutika M.; Sugumar, Vimal; Taju, Gani; Sahul Hameed, A. S.

    2017-01-01

    Background White spot disease (WSD), a major threat to sustainable aquaculture worldwide, is caused by White spot syndrome virus (WSSV). The diagnosis of WSD relies heavily on molecular detection of the virus by one-step PCR. These procedures are neither field-usable nor rapid enough considering the speed at which the virus spreads. Thus, development of a rapid, reliable and field-usable diagnostic method for the detection of WSSV infection is imperative to prevent huge economic losses. Methods/Principal Findings Here, we report on the development of a lateral flow immunoassay (LFIA) employing gold nanoparticles conjugated to a polyclonal antibody against VP28 (envelope protein of WSSV). The LFIA detected WSSV in ~20 min and showed no cross-reactivity with other shrimp viruses, viz. Monodon Baculovirus (MBV), Hepatopancreatic parvovirus (HPV) and Infectious Hypodermal and Hematopoietic Necrosis virus (IHHNV). The limit of detection (LOD) of the assay, as determined by real-time PCR, was 103 copies of WSSV. In a time course infectivity experiment, ~104 WSSV particles were injected in Litopenaeus vannamei. The LFIA could rapidly (~ 20 min) detect the virus in different tissues after 3 h (hemolymph), 6 h (gill tissue) and 12 h (head soft tissue, eye stalk, and pleopod) of infection. Based on these findings, a validation study was performed using 75 field samples collected from different geographical locations in India. The LFIA results obtained were compared with the conventional “gold standard test”, viz. one-step PCR. The analysis of results in 2x2 matrix indicated very high sensitivity (100%) and specificity (96.77%) of LFIA. Similarly, Cohen’s kappa coefficient of 0.983 suggested "very good agreement” between the developed LFIA and the conventional one-step PCR. Conclusion The LFIA developed for the rapid detection of WSSV has an excellent potential for use in the field and could prove to be a boon to the aquaculture industry. PMID:28046005

  19. High-frequency subharmonic pulsed-wave Doppler and color flow imaging of microbubble contrast agents.

    Science.gov (United States)

    Needles, A; Goertz, D E; Karshafian, R; Cherin, E; Brown, A S; Burns, P N; Foster, F S

    2008-07-01

    A recent study has shown the feasibility of subharmonic (SH) flow imaging at a transmit frequency of 20 MHz. This paper builds on these results by examining the performance of SH flow imaging as a function of transmit pressure. Further, we also investigate the feasibility of SH pulsed-wave Doppler (PWD) imaging. In vitro flow experiments were performed with a 1-mm-diameter wall-less vessel cryogel phantom using the ultrasound contrast agent Definity and an imaging frequency of 20 MHz. The phantom results show that there is an identifiable pressure range where accurate flow velocity and power estimates can be made with SH imaging at 10 MHz (SH10), above which velocity estimates are biased by radiation force effects and unstable bubble behavior, and below which velocity and power estimates are degraded by poor SNR. In vivo validation of SH PWD was performed in an arteriole of a rabbit ear, and blood velocity estimates compared well with fundamental (F20) mode PWD. The ability to suppress tissue signals using SH signals may enable the use of higher frame rates and improve sensitivity to microvascular flow or slow velocities near large vessel walls by reducing or eliminating the need for clutter filters.

  20. Identification of dominant flow structures in rapidly rotating convection of liquid metals using Dynamic Mode Decomposition

    Science.gov (United States)

    Horn, S.; Schmid, P. J.; Aurnou, J. M.

    2016-12-01

    The Earth's metal core acts as a dynamo whose efficiency in generating and maintaining the magnetic field is essentially determined by the rotation rate and the convective motions occurring in its outer liquid part. For the description of the primary physics in the outer core the idealized system of rotating Rayleigh-Bénard convection is often invoked, with the majority of studies considering only working fluids with Prandtl numbers of Pr ≳ 1. However, liquid metals are characterized by distinctly smaller Prandtl numbers which in turn result in an inherently different type of convection. Here, we will present results from direct numerical simulations of rapidly rotating convection in a fluid with Pr ≈ 0.025 in cylindrical containers and Ekman numbers as low as 5 × 10-6. In this system, the Coriolis force is the source of two types of inertial modes, the so-called wall modes, that also exist at moderate Prandtl numbers, and cylinder-filling oscillatory modes, that are a unique feature of small Prandtl number convection. The obtained flow fields were analyzed using the Dynamic Mode Decomposition (DMD). This technique allows to extract and identify the structures that govern the dynamics of the system as well as their corresponding frequencies. We have investigated both the regime where the flow is purely oscillatory and the regime where wall modes and oscillatory modes co-exist. In the purely oscillatory regime, high and low frequency oscillatory modes characterize the flow. When both types of modes are present, the DMD reveals that the wall-attached modes dominate the flow dynamics. They precess with a relatively low frequency in retrograde direction. Nonetheless, also in this case, high frequency oscillations have a significant contribution.

  1. Flow cytometric quantification of all phases of the cell cycle and apoptosis in a two-color fluorescence plot.

    Directory of Open Access Journals (Sweden)

    Christine Vignon

    Full Text Available An optimal technology for cell cycle analysis would allow the concomitant measurement of apoptosis, G0, G1, S, G2 and M phases in combination with cell surface phenotyping. We have developed an easy method in flow cytometry allowing this discrimination in an only two-color fluorescent plot. It is based on the concomitant use of 7-amino-actinomycin D and the antibodies anti-Ki67 and anti-phospho(Ser10-histone H3, both conjugated to Alexa Fluor®488 to discriminate G0 and M phases, respectively. The method is particularly valuable in a clinical setting as verified in our laboratory by analyzing human leukemic cells from marrow samples or after exposure to cell cycle modifiers.

  2. Simultaneous measurement of temperature and velocity of air flow over 1000°C using two color phosphor thermometry

    Science.gov (United States)

    Fukuta, Masatoshi; Someya, Satoshi; Munakata, Tetsuo; LCS Team

    2016-11-01

    Thermal barrier coatings were applied to the gas turbines and the internal combustion engines for the high thermal efficiency. The evaluation and the improvement of coatings require to measure transient gaseous flow near the wall with coatings. An aim of this study is to combine a two color phosphor thermometry with the PIV to measure simultaneously temperature and velocity of the gas over 1000°C. The temperature and velocity distribution of an impinging jet of high temperature air was simultaneously visualized in experiments. The temperature was estimated from an intensity ratio of luminescent in different ranges of wavelength, 500 600 nm and 400 480 nm. Uncertainty of measured temperature was less than 10°C. Temperatures measured by the developed method and by thermocouples were agreed well. The measured velocity by the PIV with phosphor particles were also agreed well with the velocity measured by a Laser Doppler Velocimeter.

  3. The Diagnostic Value of Superb Microvascular Imaging (SMI) in Detecting Blood Flow Signals of Breast Lesions: A Preliminary Study Comparing SMI to Color Doppler Flow Imaging.

    Science.gov (United States)

    Ma, Yan; Li, Gang; Li, Jing; Ren, Wei-dong

    2015-09-01

    The correlation between color Doppler flow imaging (CDFI) and Superb Microvascular Imaging (SMI) for detecting blood flow in breast lesions was investigated, as was the diagnostic value of SMI in differentiating benign from malignant breast lesions.These lesions were evaluated using both CDFI and SMI according to Adler's method. Pathologic examination showed 57 malignant lesions and 66 benign lesions. The number of blood vessels in a single mass was detected by 2 techniques (SMI and CDFI), and the difference between the 2 values (SMI-CDFI) was calculated. The optimal threshold for the diagnosis of malignant neoplasms and the diagnostic performances of SMI, CDFI, and SMI-CDFI were calculated.For the total lesions and malignant lesions alone, the difference between SMI and CDFI for detecting blood flow was significant (P < 0.01), but the difference was not significant for benign lesions (P = 0.15). The area under the receiver operating characteristic curve was 0.73 (95% confidence interval [CI]: 0.64-0.82) for CDFI; 0.81 (95% CI: 0.74-0.89) for SMI; and 0.89 (95% CI: 0.82-0.95) for SMI-CDFI. Furthermore, the modality of "SMI-CDFI" showed the best diagnostic performance.SMI provides further microvessel information in breast lesions. The diagnostic modality of "SMI-CDFI" can improve the diagnostic performance of ultrasound in the differentiation between benign and malignant masses.

  4. Single-ensemble-based eigen-processing methods for color flow imaging--Part I. The Hankel-SVD filter.

    Science.gov (United States)

    Yu, Alfred C H; Cobbold, Richard S C

    2008-03-01

    Because of their adaptability to the slow-time signal contents, eigen-based filters have shown potential in improving the flow detection performance of color flow images. This paper proposes a new eigen-based filter called the Hankel-SVD filter that is intended to process each slowtime ensemble individually. The new filter is derived using the notion of principal Hankel component analysis, and it achieves clutter suppression by retaining only the principal components whose order is greater than the clutter eigen-space dimension estimated from a frequency based analysis algorithm. To assess its efficacy, the Hankel-SVD filter was first applied to synthetic slow-time data (ensemble size: 10) simulated from two different sets of flow parameters that model: 1) arterial imaging (blood velocity: 0 to 38.5 cm/s, tissue motion: up to 2 mm/s, transmit frequency: 5 MHz, pulse repetition period: 0.4 ms) and 2) deep vessel imaging (blood velocity: 0 to 19.2 cm/s, tissue motion: up to 2 cm/s, transmit frequency: 2 MHz, pulse repetition period: 2.0 ms). In the simulation analysis, the post-filter clutter-to- blood signal ratio (CBR) was computed as a function of blood velocity. Results show that for the same effective stopband size (50 Hz), the Hankel-SVD filter has a narrower transition region in the post-filter CBR curve than that of another type of adaptive filter called the clutter-downmixing filter. The practical efficacy of the proposed filter was tested by application to in vivo color flow data obtained from the human carotid arteries (transmit frequency: 4 MHz, pulse repetition period: 0.333 ms, ensemble size: 10). The resulting power images show that the Hankel-SVD filter can better distinguish between blood and moving-tissue regions (about 9 dB separation in power) than the clutter-downmixing filter and a fixed-rank multi ensemble-based eigen-filter (which showed a 2 to 3 dB separation).

  5. Bienzymatic Biosensor for Rapid Detection of Aspartame by Flow Injection Analysis

    Directory of Open Access Journals (Sweden)

    Maria-Cristina Radulescu

    2014-01-01

    Full Text Available A rapid, simple and stable biosensor for aspartame detection was developed. Alcohol oxidase (AOX, carboxyl esterase (CaE and bovine serum albumin (BSA were immobilised with glutaraldehyde (GA onto screen-printed electrodes modified with cobalt-phthalocyanine (CoPC. The biosensor response was fast. The sample throughput using a flow injection analysis (FIA system was 40 h−1 with an RSD of 2.7%. The detection limits for both batch and FIA measurements were 0.1 µM for methanol and 0.2 µM for aspartame, respectively. The enzymatic biosensor was successfully applied for aspartame determination in different sample matrices/commercial products (liquid and solid samples without any pre-treatment step prior to measurement.

  6. Bienzymatic biosensor for rapid detection of aspartame by flow injection analysis.

    Science.gov (United States)

    Radulescu, Maria-Cristina; Bucur, Bogdan; Bucur, Madalina-Petruta; Radu, Gabriel Lucian

    2014-01-09

    A rapid, simple and stable biosensor for aspartame detection was developed. Alcohol oxidase (AOX), carboxyl esterase (CaE) and bovine serum albumin (BSA) were immobilised with glutaraldehyde (GA) onto screen-printed electrodes modified with cobalt-phthalocyanine (CoPC). The biosensor response was fast. The sample throughput using a flow injection analysis (FIA) system was 40 h⁻¹ with an RSD of 2.7%. The detection limits for both batch and FIA measurements were 0.1 µM for methanol and 0.2 µM for aspartame, respectively. The enzymatic biosensor was successfully applied for aspartame determination in different sample matrices/commercial products (liquid and solid samples) without any pre-treatment step prior to measurement.

  7. Rapidity and pt dependence of identified-particle elliptic flow at RHIC

    Science.gov (United States)

    Sanders, S. J.; BRAHMS Collaboration

    2007-08-01

    Elliptic flow has been measured by the BRAHMS experiment as a function of transverse momentum and pseudorapidity for the Au+Au reaction at \\sqrt{s_{NN}} = 200 GeV. Identified-particle v2(η, pt) values were obtained with the two BRAHMS spectrometers at pseudorapidities ηap 0, 1 and 3.4. The results show that the differential v2(η, pt) values for a given particle type are essentially constant over the covered pseudorapidity range. It is suggested that the dominant cause of the observed fall-off of the integral v2 values going away from mid-rapidity is a corresponding softening of the particle spectra.

  8. Flow cytometry for rapid detection of Salmonella spp. in seed sprouts

    Directory of Open Access Journals (Sweden)

    Bledar Bisha

    2014-12-01

    Full Text Available Seed sprouts (alfalfa, mung bean, radish, etc. have been implicated in several recent national and international outbreaks of salmonellosis. Conditions used for sprouting are also conducive to the growth of Salmonella. As a result, this pathogen can quickly grow to very high cell densities during sprouting without any detectable organoleptic impact. Seed sprouts typically also support heavy growth (~108 CFU g−1 of a heterogeneous microbiota consisting of various bacterial, yeast, and mold species, often dominated by non-pathogenic members of the family Enterobacteriaceae. This heavy background may present challenges to the detection of Salmonella, especially if this pathogen is present in relatively low numbers. We combined DNA-based fluorescence in situ hybridization (FISH with flow cytometry (FCM for the rapid molecular detection of Salmonella enterica ser. Typhimurium in artificially contaminated alfalfa and other seed sprouts. Components of the assay included a set of cooperatively binding probes, a chemical blocking treatment intended to reduce non-specific background, and sample concentration via tangential flow filtration (TFF. We were able to detect S. Typhimurium in sprout wash at levels as low as 103 CFU ml−1 sprout wash (104 CFU g−1 sprouts against high microbial backgrounds (~108 CFU g−1 sprouts. Hybridization times were typically 30 min, with additional washing, but we ultimately found that S. Typhimurium could be readily detected using hybridization times as short as 2 min, without a wash step. These results clearly demonstrate the potential of combined DNA-FISH and FCM for rapid detection of Salmonella in this challenging food matrix and provide industry with a useful tool for compliance with sprout production standards proposed in the Food Safety Modernization Act (FSMA.

  9. Stopped-flow ultra-rapid-scanning Fourier transform infrared spectroscopy on the millisecond time scale.

    Science.gov (United States)

    Reback, Matthew L; Roske, Christopher W; Bitterwolf, Thomas E; Griffiths, Peter R; Manning, Christopher J

    2010-08-01

    Full-range mid-infrared spectra were measured during the reaction of CpCo(CO)(2) with nitrosyl chloride by interfacing a rapid-mixing stopped-flow device with an ultra-rapid-scanning Fourier transform infrared (FT-IR) spectrometer having a temporal resolution of 5 ms. Changes to the data acquisition hardware of this spectrometer now allow a sequence of well over 2000 spectra to be collected without interruption. Two transient species were observed spectroscopically during the first 500 ms of the reaction of CpCo(CO)(2) with nitrosyl chloride. The shortest-lived species that was observed, [CpCo(CO)(2)(NO)](+), had a half-life of approximately 20 ms at 25 degrees C and approximately 70 ms at 10 degrees C. This intermediate transformed into a longer-lived (approximately 0.5 s) intermediate, CpCo(NO)Cl. Potential intermediate species with one CO and one NO ligand, such as [CpCo(CO)(NO)](+) and CpCo(CO)(NO)Cl, were not observed, although the possibility that they exist cannot be ruled out.

  10. Dual-Quantum-Dots-Labeled Lateral Flow Strip Rapidly Quantifies Procalcitonin and C-reactive Protein

    Science.gov (United States)

    Qi, XiaoPing; Huang, YunYe; Lin, ZhongShi; Xu, Liang; Yu, Hao

    2016-03-01

    In the article, a dual-quantum-dots-labeled (dual-QDs-labeled) lateral flow strip (LFS) method was developed for the simultaneous and rapid quantitative detection of procalcitonin (PCT) and C-reactive protein (CRP) in the blood. Two QD-antibody conjugates with different fluorescence emission spectra were produced and sprayed on the LFS to capture PCT and CRP in the blood. Furthermore, a double antibody sandwich method for PCT and, meanwhile, a competitive inhibition method for CRP were employed in the LFS. For PCT and CRP in serum assayed by the dual-QDs-labeled LFS, their detection sensitivities reached 0.1 and 1 ng/mL, respectively, and their linear quantitative detection ranges were from 0.3 to 200 ng/mL and from 50 to 250 μg/mL, respectively. There was little evidence that the PCT and CRP assays would be interfered with each other. The correlations for testing CRP and PCT in clinical samples were 99.75 and 97.02 %, respectively, between the dual-QDs-labeled LFS we developed and commercial methods. The rapid quantification of PCT and CRP on dual-QDs-labeled LFS is of great clinical value to distinguish inflammation, bacterial infection, or viral infection and to provide guidance for the use of antibiotics or other medicines.

  11. High-Resolution Digital Two-Color PIV for Turbomachinery Flows

    Science.gov (United States)

    Copenhaver, W.; Gogineni, S.; Goss, L.

    1996-11-01

    Turbomachinery flows are inherently unsteady. However, steady design methods are currently used to develop turbomachinery, with the lack of basic understanding of unsteady effects being compensated by use of extensive empirical correlations. Conventional laser anemometry provides quantitative evidence of unsteady effects in turbomachinery but is limited in fully exploring this phenomenon. The PIV technique holds great promise for elucidating unsteady flow mechanisms in turbomachinery if obstacles to its application in a transonic turbomachine can be overcome. Implementation involves critical issues such as tracer seeding and optical access for transmitter and receiver. Initially, an 18-in.-dia. axial fan is used to explore these issues. One optical configuration considered is the fiber-optic fanning light sheet in conjunction with high-power pulsed lasers. Instantaneous velocity measurements are made between blades at different spanwise locations.

  12. A nonlinear self-similar solution to barotropic flow over rapidly varying topography

    Science.gov (United States)

    Ibanez, Ruy; Kuehl, Joseph

    2016-11-01

    Beginning from the Shallow Water Equations (SWE), a nonlinear self-similar analytic solution is derived for barotropic flow over rapidly varying topography. We study conditions relevant to the ocean slope where the flow is dominated by Earth's rotation and topography. Attention is paid to the northern Gulf of Mexico slope with application to pollutant dispersion and the Norwegian Coastal Current which sheds eddies into the Lofoten Basin that are believe to influence deep water formation. The solution is found to extend the topographic β-plume solution (Kuehl 2014, GRL) in two ways: 1) The solution is valid for intensifying jets. 2) The influence of nonlinear advection is included. The SWE are scaled to the case of a topographically controlled jet, then solved by introducing a similarity variable η = Cxy . The nonlinear solution, valid for topographies h =h0 - αxy3 , takes the form of the Lambert W Function for velocity. The linear solution, valid for topographies h =h0 - αxyγ , takes the form of the Error Function for transport. Kuehl's results considered the case - 1 <= γ < 1 which admits expanding jets, while the new result consider the case γ < - 1 which admits intensifying jets.

  13. A rapid and reversible skull optical clearing method for monitoring cortical blood flow

    Science.gov (United States)

    Zhang, Chao; Zhao, Yanjie; Shi, Rui; Zhu, Dan

    2016-03-01

    In vivo cortex optical imaging is of great important for revealing both structural and functional architecture of brain with high temporal-spatial resolution. To reduce the limitation of turbid skull, researchers had to establish various skull windows or directly expose cortex through craniotomy. Here we developed a skull optical clearing method to make skull transparent. Laser speckle contrast imaging technique was used to monitor the cortical blood flow after topical treatment with the optical clearing agents. The results indicated that the image contrast increased gradually, and then maintained at a high level after 15 min for adult mice, which made the image quality and resolution of micro-vessels nearly approximate to those of exposed cortex. Both the cortical blood flow velocity almost kept constant after skull became transparent. Besides, the treatment of physiological saline on the skull could make skull return to the initial state again and the skull could become transparent again when SOCS retreated it. Thus, we could conclude that the skull optical clearing method was rapid, valid, reversible and safe, which provided us available approach for performing the cortical structural and functional imaging at high temporal-spatial resolution.

  14. A single-ensemble clutter rejection method based on the analytic geometry for ultrasound color flow imaging.

    Science.gov (United States)

    You, Wei; Wang, Yuanyuan

    2011-11-01

    In ultrasound color flow imaging (CFI), the single-ensemble eigen-based filters can reject clutter components using each slow-time ensemble individually. They have shown excellent spatial adaptability. This article proposes a novel clutter rejection method called the single-ensemble geometry filter (SGF), which is derived from an analytic geometry perspective. If the transmitted pulse number M equals two, the clutter component distribution on a two-dimensional (2-D) plane will be similar to a tilted ellipse. Therefore, the direction of the major axis of the ellipse can be used as the first principal component of the autocorrelation matrix estimated from multiple ensembles. Then the algorithm is generalized from 2-D to a higher dimensional space by using linear algebra representations of the ellipse. Comparisons have been made with the high-pass filter (HPF), the Hankel-singular value decomposition (SVD) filter and the recursive eigen-decomposition (RED) method using both simulated and human carotid data. Results show that compared with HPF and Hankel-SVD, the proposed filter causes less bias on the velocity estimation when the clutter velocity is close to that of the blood flow. On the other hand, the proposed filter does not need to update the autocorrelation matrix and can achieve better spatial adaptability than the RED.

  15. Short-term effects of intravitreal triamcinolone acetonide injection on ocular blood flow evaluated with color Doppler ultrasonography

    Institute of Scientific and Technical Information of China (English)

    Mustafa; Alpaslan; Anayol; Yasin; Toklu; Elif; Asik; Kamberoglu; Sabri; Raza; Hasan; Basri; Arifoglu; Huseyin; Simavli; Ayse; Gul; Kocak; Altintas; Saban; Simsek

    2014-01-01

    AIM:To evaluate the changes in ocular blood flow with color Doppler ultrasonography(CDU) after intravitreal triamcinolone acetonide(IVTA) injection.METHODS:A total of 46 patients who underwent IVTA(4 mg/0.1 mL) injection for diabetic macular edema(DME)(n =22), central retinal vein occlusion(CRVO)(n =12) and choroidal neovascular membrane(CNVM)(n =12) were included in the study. Peak systolic velocity(PSV), end diastolic velocity(EDV) and resistivity index(RI) were measured from the ophthalmic artery(OA), the central retinal artery(CRA) and the posterior ciliary artery(PCA)of each patient with CDU before, at the end of the first week and at the end of the first month following IVTA injection.RESULTS:In the DME group, PSV of OA at the first of the first month(mean ±SD)(37.48 ±10.87 cm/s) increased compared to pre-injection value(31.39 ±10.84 cm/s)(P =0.048). There was a statistically significant decrease(P =0.049) in PSV of CRA at the end of the first month(7.97±2.67 cm/s) compared to the pre-injection(9.47±3.37 cm/s).There was not any statistically significant difference onthe other parameters in the DME group. Also, there was not any statistically significant difference on the ocular blood flow values in the CRVO and CNVM groups.CONCLUSION:We observed that 4 mg/0.1 mL IVTA increased PSV of OA and decreased PSV of CRA in DME patients and did not have any effect on ocular blood flow values of CRVO and CNVM patients.

  16. Short-term effects of intravitreal triamcinolone acetonide injection on ocular blood flow evaluated with color Doppler ultrasonography

    Directory of Open Access Journals (Sweden)

    Mustafa Alpaslan Anayol

    2014-10-01

    Full Text Available AIM:To evaluate the changes in ocular blood flow with color Doppler ultrasonography (CDU after intravitreal triamcinolone acetonide (IVTA injection.METHODS: A total of 46 patients who underwent IVTA (4 mg/0.1 mL injection for diabetic macular edema (DME (n=22, central retinal vein occlusion (CRVO (n=12 and choroidal neovascular membrane (CNVM (n=12 were included in the study. Peak systolic velocity (PSV, end diastolic velocity (EDV and resistivity index (RI were measured from the ophthalmic artery (OA, the central retinal artery (CRA and the posterior ciliary artery (PCA of each patient with CDU before, at the end of the first week and at the end of the first month following IVTA injection.RESULTS:In the DME group, PSV of OA at the first of the first month (mean±SD (37.48±10.87 cm/s increased compared to pre-injection value (31.39±10.84 cm/s (P=0.048. There was a statistically significant decrease (P=0.049 in PSV of CRA at the end of the first month (7.97±2.67 cm/s compared to the pre-injection (9.47±3.37 cm/s. There was not any statistically significant difference on the other parameters in the DME group. Also, there was not any statistically significant difference on the ocular blood flow values in the CRVO and CNVM groups.CONCLUSION: We observed that 4 mg/0.1 mL IVTA increased PSV of OA and decreased PSV of CRA in DME patients and did not have any effect on ocular blood flow values of CRVO and CNVM patients.

  17. Color Doppler evaluation of the ocular arterial flow changes in chronic obstructive pulmonary disease

    Energy Technology Data Exchange (ETDEWEB)

    Ozer, Tulay [Department of Radiology, Karaelmas University, School of Medicine, Tip Fakueltesi, Radyoloji AD, 67600-Kozlu, Zonguldak (Turkey)]. E-mail: ozertulay@yahoo.com; Altin, Remzi [Department of Pulmonary Medicine, Karaelmas University, School of Medicine, Kozlu, Zonguldak (Turkey); Ugurbas, Suat Hayri [Department of Ophthalmology, Karaelmas University, School of Medicine, Kozlu, Zonguldak (Turkey); Ozer, Yetkin [Department of Anesthesiology and Reanimation, Karaelmas University, School of Medicine, Kozlu, Zonguldak (Turkey); Mahmutyazicioglu, Kamran [Department of Radiology, Karaelmas University, School of Medicine, Tip Fakueltesi, Radyoloji AD, 67600-Kozlu, Zonguldak (Turkey); Kart, Levent [Department of Pulmonary Medicine, Karaelmas University, School of Medicine, Kozlu, Zonguldak (Turkey)

    2006-01-15

    Purpose: To evaluate the hemodynamic changes in the extraocular orbital vessels of the patients with chronic obstructive pulmonary disease (COPD), using color Doppler ultrasonography (CDU) technique, and to compare the results with those of healthy control subjects. Methods: Forty-five patients with COPD and 17 healthy control subjects were included in this study. Patients with COPD were classified according to the Global Initiative for Chronic Obstructive Lung Disease (GOLD). Fifteen patients of stage I COPD (mild airflow limitation), stage II COPD (worsening airflow limitation) or stage III COPD (severe airflow limitation) were enrolled into Group I, II and III, respectively. End tidal carbon dioxide (EtCO{sub 2}), peripheral oxygen saturation (SpO{sub 2}), pulse rate (PR) and respiratory rate (RR) were measured by using capnograph/pulse oximeter in all patients. Measurements were performed in only one randomly chosen eye of each participant. The peak systolic velocity (PSV), end-diastolic velocity (EDV), and resistance index (RI) were measured in the ophthalmic artery (OA), central retinal artery (CRA), lateral short posterior ciliary artery (LPCA) and medial short posterior ciliary artery (MPCA), using CDU technique. Results: The PSV measurements of the OA were significantly higher in Groups II and III compared to control group (p < 0.01, p < 0.001, respectively). The RI values from OA and CRA were significantly higher in Group II and III than the control group (p < 0.05). The RI values of LPCA and MPCA were also significantly higher in Group II than the control subjects (p < 0.05). When RI values were compared, mean values of LPCA and MPCA were significantly lower in Group III than in Group II (p < 0.05). There were no significant differences between Group I and control patients about PSVs, EDVs and RI values of all arteries Statistically significant correlations were found for the EtCO{sub 2} with PSV (r = 0.53, p < 0.01) and EDV (r = 0.51, p < 0.01) of the

  18. A Rapid and Low-Cost Nonlithographic Method to Fabricate Biomedical Microdevices for Blood Flow Analysis

    Directory of Open Access Journals (Sweden)

    Elmano Pinto

    2014-12-01

    Full Text Available Microfluidic devices are electrical/mechanical systems that offer the ability to work with minimal sample volumes, short reactions times, and have the possibility to perform massive parallel operations. An important application of microfluidics is blood rheology in microdevices, which has played a key role in recent developments of lab-on-chip devices for blood sampling and analysis. The most popular and traditional method to fabricate these types of devices is the polydimethylsiloxane (PDMS soft lithography technique, which requires molds, usually produced by photolithography. Although the research results are extremely encouraging, the high costs and time involved in the production of molds by photolithography is currently slowing down the development cycle of these types of devices. Here we present a simple, rapid, and low-cost nonlithographic technique to create microfluidic systems for biomedical applications. The results demonstrate the ability of the proposed method to perform cell free layer (CFL measurements and the formation of microbubbles in continuous blood flow.

  19. [Rapid detection of Macrobrachium rosenbergii nodavirus isolated in China by a reverse-transcription loop-mediated isothermal amplification assay combined with a lateral flow dipstick method].

    Science.gov (United States)

    Lin, Feng; Liu, Li; Hao, Gui-Jie; Cao, Zheng; Sheng, Peng-Cheng; Wu, Ying-Lei; Shen, Jin-Yu

    2014-09-01

    White coloration of the muscle of the giant river prawn (Macrobrachium rosenbergii) is a serious problem in China. The Macrobrachium rosenbergii Nodavirus (MrNV) has been confirmed to be the pathogen that causes this disorder. To develop a rapid, sensitive and specific technology for the detection of Macrobrachium rosenbergii Nodavirus isolated from China (MrNV-China), a reverse-transcription loop- mediated isothermal amplification assay combined with a lateral flow dipstick (RT-LAMP-LFD) assay method is described. A set of four primers and a labeled probe were designed specifically to recognize six distinct regions of the MrNV RNA2 gene. Results showed the sensitivity of the RT-LAMP-LFD assay was ten-times higher than the reverse-transcription loop-mediated isothermal amplification assay (RT-LAMP) with agarose gel electrophoresis. The assay was conducted with one-step amplification at 61°C in a single tube within 45 min. No product was generated from shrimps infected with other viruses, including DNA viruses (infectious hypodermal and hematopoietic necrosis virus (IHHNV); white spot syndrome virus (WSSV)) and RNA viruses (Taura syndrome virus (TSV); infectious myonecrosis virus (IMNV); yellow head virus (YHV)). Results were visualized by the LFD method. Therefore, the described rapid and sensitive assay is potentially useful for MrNV detection.

  20. Two- and three-color immunofluorescence using aminocoumarin, fluorescein, and phycoerythrin-labelled antibodies and single laser flow cytometry.

    Science.gov (United States)

    Delia, D; Martinez, E; Fontanella, E; Aiello, A

    1991-01-01

    Antibodies coupled to 7-aminocoumarin (AMCA) emit a bright blue fluorescence under ultraviolet (UV) excitation and are therefore ideal for three-color immunofluorescence (IF) with fluorescein (FITC) and phycoerythrin (PE) labeled reagents; however, due to the different absorption spectra, the use of these fluorophores for multicolor flow-cytometric analysis requires a double light excitation source (e.g., two-laser system). We report a strategy which uses a single argon-ion laser to simultaneously excite AMCA, FITC, and PE, thus allowing the flow cytometric analysis of three immunological parameters. When the UV-visible argon-ion laser is fitted with an appropriate set of mirrors, the 35.1-363.8 nm (UV) and 488 nm wavelengths (accounting for 80 mW and 520 mW, respectively) are simultaneously generated; these lines can then be exactly focused on the same observation point by an achromatic cylindrical lens. A number of comparative analysis were performed with this instrumental set up to verify the sensitivity of AMCA IF and its possible application for multicolor immunophenotypic evaluation of blood cell subsets. When AMCA- and FITC-labeled antimouse Ig antibodies were assessed for their ability to detect limiting amounts of mouse monoclonal antibody bound to cells, the former was less sensitive than the latter. A number of factors, including differences in excitation energy (80 mW for AMCA and 520 mw for FITC) and extinction coefficients (1.9 x 10(4) for AMCA and 6 x 10(4) for FITC) could explain this result.(ABSTRACT TRUNCATED AT 250 WORDS)

  1. Analysis of Ground-Water Flow in the Madison Aquifer using Fluorescent Dyes Injected in Spring Creek and Rapid Creek near Rapid City, South Dakota, 2003-04

    Science.gov (United States)

    Putnam, Larry D.; Long, Andrew J.

    2007-01-01

    The Madison aquifer, which contains fractures and solution openings in the Madison Limestone, is used extensively for water supplies for the city of Rapid City and other suburban communities in the Rapid City, S. Dak., area. The 48 square-mile study area includes the west-central and southwest parts of Rapid City and the outcrops of the Madison Limestone extending from south of Spring Creek to north of Rapid Creek. Recharge to the Madison Limestone occurs when streams lose flow as they cross the outcrop. The maximum net loss rate for Spring and Rapid Creek loss zones are 21 and 10 cubic feet per second (ft3/s), respectively. During 2003 and 2004, fluorescent dyes were injected in the Spring and Rapid Creek loss zones to estimate approximate locations of preferential flow paths in the Madison aquifer and to measure the response and transit times at wells and springs. Four injections of about 2 kilograms of fluorescein dye were made in the Spring Creek loss zone during 2003 (sites S1, S2, and S3) and 2004 (site S4). Injection at site S1 was made in streamflow just upstream from the loss zone over a 12-hour period when streamflow was about equal to the maximum loss rate. Injections at sites S2, S3, and S4 were made in specific swallow holes located in the Spring Creek loss zone. Injection at site R1 in 2004 of 3.5 kilograms of Rhodamine WT dye was made in streamflow just upstream from the Rapid Creek loss zone over about a 28-hour period. Selected combinations of 27 wells, 6 springs, and 3 stream sites were monitored with discrete samples following the injections. For injections at sites S1-S3, when Spring Creek streamflow was greater than or equal to 20 ft3/s, fluorescein was detected in samples from five wells that were located as much as about 2 miles from the loss zone. Time to first arrival (injection at site S1) ranged from less than 1 to less than 10 days. The maximum fluorescein concentration (injection at site S1) of 120 micrograms per liter (ug/L) at well CO

  2. Contribution of spiral artery blood flow changes assessed by transvaginal color Doppler sonography for predicting endometrial pathologies

    Directory of Open Access Journals (Sweden)

    Suna Kabil Kucur

    2013-01-01

    Full Text Available ive: To investigate the diagnostic value of blood flow measurements in spiral artery by transvaginal color Doppler sonography (CDS in predicting endometrial pathologies.Methods: Ninety-seven patients presenting with abnormal uterine bleeding and requiring endometrial assessment were included in this prospective observational study. Endometrial thickness, structure and echogenicity were recorded. Pulsatility index (PI and resistive index (RI of the spiral artery were measured by transvaginal CDS. Endometrial sampling was performed for all subjects. Sonographic and hystopathologic findings were compared.Results: The histopathological diagnoses were as follows; 39 cases (40.2% endometrial polyp, 9 cases (9.3% endometrial hyperplasia, 10 cases (10.3 submucous myoma, 7 cases (7.2% endometrium cancer, and 32 cases (33% nonspecific findings. The spiral artery PI in endometrium cancer group was highly significantly lower than other groups (p<0.01. The spiral artery RI was also significantly lower in the patients with malignant histology (p<0.05. Conclusion: Endometrial pathologies are associated significantly with endometrial spiral artery Doppler changes.Key words: Spiral artery, Doppler ultrasonography, endometrium

  3. Simultaneous removal of color, organic compounds and nutrients in azo dye-containing wastewater using up-flow constructed wetland.

    Science.gov (United States)

    Ong, Soon-An; Uchiyama, Katsuhiro; Inadama, Daisuke; Yamagiwa, Kazuaki

    2009-06-15

    Combination of aerobic and anaerobic processes in constructed wetlands can enhance the treatment performance in textile wastewater. This study assessed the treatment of azo dye Acid Orange 7 (AO7) and nutrients using five laboratory-scale up-flow constructed wetlands (UFCW) with and without supplementary aeration, and with different emergent plants. Supplementary aeration controlled the size of aerobic and anaerobic zones in the UFCW reactors as evidenced by the oxidation-reduction potential (ORP) and dissolved oxygen (DO) profile of the UFCW. The AO7 removal efficiency was above 95% in all UFCW reactors and most of the color was extensively removed in the anaerobic region of the UFCW beds. The intermediates produced through the breakage of azo bond were significantly reduced in the UFCW reactors with supplementary aeration. The results indicated the applicability of the UFCW reactors to the treatment of azo dye-containing wastewater. The removals of T-N and T-P were in the range of 60-67% and 26-37%, respectively, among the UFCW reactors. The COD and NH(4)-N removals in the aerated reactors were about 86 and 96%, respectively. On the other hand, the COD and NH(4)-N removals were in the range of 78-82% and 41-48%, respectively, in the non-aerated reactors. The supplementary aeration enhanced the removal efficiencies in organic matter, NH(4)-N and aromatic amines in the UFCW reactors.

  4. Rapid detection of pesticides not amenable to multi-residue methods by flow injection-tandem mass spectrometry

    NARCIS (Netherlands)

    Mol, J.G.J.; Dam, van R.C.J.

    2014-01-01

    Flow injection combined with tandem mass spectrometry (MS/MS) was investigated for the rapid detection of highly polar pesticides that are not amenable to multi-residue methods because they do not partition into organic solvents and require dedicated chromatographic conditions. The pesticides includ

  5. [Rapid screening and confirming carcinogenic banned azo colorants in textiles by high performance liquid chromatography-linear ion trap/orbitrap high-resolution mass spectrometry].

    Science.gov (United States)

    Yun, Huan; Liu, Xin; Wang, Jing; Yan, Hua; Cui, Fengyun; Zhang, Zhaohui

    2013-09-01

    A method of high performance liquid chromatography-linear ion trap/orbitrap highresolution mass spectrometry (HPLC-LTP/Orbitrap MS) was ued to screen and confirm-banned azo colorants in textiles rapidly. The analytes were reduced to carcinogenic aromatic amines with sodium dithionite in citrate buffer solution. The reduced solution was extracted bydiatomite, and loadd onto an Acquity UPLC BEH C18 column (50 mm x 2.1 MM. 1.7 microm) with a gradient elution of methanol and 0.1% (v/v) methane acid aqueous solution, and finally detected by linear ion trap/orbitrap high-resolution mass spectrometry in positive ESI mode. In mass spectrometry method, the MS spectrum of high-resolution and the collision induced dissociation (CID) spectrum of data-dependent scan mode were used for screening analysis and conformation, respectively. The calibration curves showed a good linearity in the range of 0.05 -2.00 mg/b, and the correlation coefficients (r) were higher than 0.99. By detecting spiked samples, the limits of quantification were 0.08 mg/kg for all the residues and the recoveries were in the range of 65.5% - 111.5% with the relative standard deviations (RSDs) between 0.87% and 2.49%. The results indicate that the method is simple, rapid, sensitive and suitable for the qualitative and quantitative analysis of carcinogenic aromatic amines in textiles.

  6. Comparison of the molecular mass and optical properties of colored dissolved organic material in two rivers and coastal waters by flow field-flow fractionation.

    Science.gov (United States)

    Zanardi-Lamardo, Eliete; Clark, Catherine D; Moore, Cynthia A; Zika, Rod G

    2002-07-01

    Colored dissolved organic material (CDOM) is an important sunlight absorbing substance affecting the optical properties of natural waters. However, little is known about its structural and optical properties mainly due to its complex matrix and the limitation of the techniques available. A comparison of two southwestern Florida rivers [the Caloosahatchee River (CR) and the Shark River (SR)] was done in terms of molecular mass (MM) and diffusion coefficients (D). The novel technique Frit inlet/frit outlet-flow field-flow fractionation (FIFO-FIFFF) with absorbance and fluorescence detectors was used to determine these properties. The SR receives organic material from the Everglades. By contrast, the CR arises from Lake Okeechobee in central Florida, receiving anthropogenic inputs, farming runoff, and natural organics. Both rivers discharge to the Gulf of Mexico. Fluorescence identified, for both rivers, two different MM distributions in low salinity water samples: the first was centered at approximately 1.7 kDa (CR) and approximately 2 kDa (SR); the second centered at approximately 13 kDa for both rivers, which disappeared gradually in the river plumes to below detection limit in coastal waters. Absorbance detected only one MM distribution centered at approximately 2 kDa (CR) and 2.2-2.4 kDa (SR). Fluorescence in general peaked at a lower MM than absorbance, suggesting a different size distribution for fluorophores vs chromophores. A photochemical study showed that, after sunlight, irradiated freshwater samples have similar characteristics to more marine waters, including a shift in MM distribution of chromophores. The differences observed between the rivers in the optical characteristics, MM distributions, and D values suggest that the CDOM sources, physical, and photochemical degradation processes are different for these two rivers.

  7. An approach for diagnosing plasma cell myeloma by three-color flow cytometry based on kappa/lambda ratios of CD38-gated CD138+ cells

    Directory of Open Access Journals (Sweden)

    Nakayama Shoko

    2012-09-01

    Full Text Available Abstract Background World Health Organization (WHO criteria are commonly used to diagnose plasma cell myeloma (PCM; however, these criteria are complex and require several laboratory parameters. For differentiating reactive plasmacytosis from clonal plasma cell (PC neoplasms such as PCM, it is important to accurately determine the expression of cytoplasmic immunoglobulin light chains. Methods We retrospectively analyzed the records of 27 selected patients with PCM who underwent bone biopsies for confirmative diagnosis according to WHO criteria. Twenty-three controls were also investigated. In the present study, all the samples were analyzed using flow cytometry (FC in the side scatter vs. CD38 histogram mode, and the CD38-gated PC population was identified. Bivariate histograms of CD138/kappa and CD138/lambda were assessed, and the ratios of dual-positive cells to the CD138+ PC population were calculated. The kappa/lambda ratio was defined as the ratio of CD138/kappa to CD138/lambda. Results PCM cells were distinguished from normal PCs using cutoff levels between 0.76 and 1.5, at a sensitivity of 96.3% and specificity of 95.7%. Conclusions Three-color FC analysis is simple to perform and inexpensive, with clinically relevant data obtained soon after the completion of FC measurements. The detection of the cytoplasmic kappa/lambda ratio of CD38-gated CD138+ PCs may be a useful tool in the diagnosis of PCM. To the best of our knowledge, this report represents the first diagnostic assessment of the cytoplasmic kappa/lambda ratio in CD38-gated CD138+ PCs using FC analysis. This method may help in more simple, efficient, rapid, and accurate diagnosis of PCM. Virtual slides The virtual slide(s for this article can be found here: http://www.diagnosticpathology.diagnomx.eu/vs/1568085959771735

  8. Ratio of left ventricular peak E-wave velocity to flow propagation velocity assessed by color M-mode Doppler echocardiography in first myocardial infarction

    DEFF Research Database (Denmark)

    Møller, J E; Søndergaard, E; Seward, J B;

    2000-01-01

    OBJECTIVES: To determine the ability of the ratio of peak E-wave velocity to flow propagation velocity (E/Vp) measured with color M-mode Doppler echocardiography to predict in-hospital heart failure and cardiac mortality in an unselected consecutive population with first myocardial infarction (MI......). BACKGROUND: Several experimental studies indicate color M-mode echocardiography to be a valuable tool in the evaluation of diastolic function, but data regarding the clinical value are lacking. METHODS: Echocardiography was performed within 24 h of arrival at the coronary care unit in 110 consecutive...... or =1.5 measured with color M-mode echocardiography is a strong predictor of in-hospital heart failure. Furthermore, E/Vp is superior to systolic measurements in predicting 35 day survival although Dt

  9. Python tools for rapid development, calibration, and analysis of generalized groundwater-flow models

    Science.gov (United States)

    Starn, J. J.; Belitz, K.

    2014-12-01

    National-scale water-quality data sets for the United States have been available for several decades; however, groundwater models to interpret these data are available for only a small percentage of the country. Generalized models may be adequate to explain and project groundwater-quality trends at the national scale by using regional scale models (defined as watersheds at or between the HUC-6 and HUC-8 levels). Coast-to-coast data such as the National Hydrologic Dataset Plus (NHD+) make it possible to extract the basic building blocks for a model anywhere in the country. IPython notebooks have been developed to automate the creation of generalized groundwater-flow models from the NHD+. The notebook format allows rapid testing of methods for model creation, calibration, and analysis. Capabilities within the Python ecosystem greatly speed up the development and testing of algorithms. GeoPandas is used for very efficient geospatial processing. Raster processing includes the Geospatial Data Abstraction Library and image processing tools. Model creation is made possible through Flopy, a versatile input and output writer for several MODFLOW-based flow and transport model codes. Interpolation, integration, and map plotting included in the standard Python tool stack also are used, making the notebook a comprehensive platform within on to build and evaluate general models. Models with alternative boundary conditions, number of layers, and cell spacing can be tested against one another and evaluated by using water-quality data. Novel calibration criteria were developed by comparing modeled heads to land-surface and surface-water elevations. Information, such as predicted age distributions, can be extracted from general models and tested for its ability to explain water-quality trends. Groundwater ages then can be correlated with horizontal and vertical hydrologic position, a relation that can be used for statistical assessment of likely groundwater-quality conditions

  10. Rapid Detection of Listeria by Bacteriophage Amplification and SERS-Lateral Flow Immunochromatography.

    Science.gov (United States)

    Stambach, Nicholas R; Carr, Stephanie A; Cox, Christopher R; Voorhees, Kent J

    2015-12-14

    A rapid Listeria detection method was developed utilizing A511 bacteriophage amplification combined with surface-enhanced Raman spectroscopy (SERS) and lateral flow immunochromatography (LFI). Anti-A511 antibodies were covalently linked to SERS nanoparticles and printed onto nitrocellulose membranes. Antibody-conjugated SERS nanoparticles were used as quantifiable reporters. In the presence of A511, phage-SERS nanoparticle complexes were arrested and concentrated as a visible test line, which was interrogated quantitatively by Raman spectroscopy. An increase in SERS intensity correlated to an increase in captured phage-reporter complexes. SERS limit of detection was 6 × 10(6) pfu·mL(-1), offering detection below that obtainable by the naked eye (LOD 6 × 10(7) pfu·mL(-1)). Phage amplification experiments were carried out at a multiplicity of infection (MOI) of 0.1 with 4 different starting phage concentrations monitored over time using SERS-LFI and validated by spot titer assay. Detection of L. monocytogenes concentrations of 1 × 10(7) colony forming units (cfu)·mL(-1), 5 × 10(6) cfu·mL(-1), 5 × 10(5) cfu·mL(-1) and 5 × 10(4) cfu·mL(-1) was achieved in 2, 2, 6, and 8 h, respectively. Similar experiments were conducted at a constant starting phage concentration (5 × 10(5) pfu·mL(-1)) with MOIs of 1, 2.5, and 5 and were detected in 2, 4, and 5 h, respectively.

  11. Rapid Detection of Listeria by Bacteriophage Amplification and SERS-Lateral Flow Immunochromatography

    Directory of Open Access Journals (Sweden)

    Nicholas R. Stambach

    2015-12-01

    Full Text Available A rapid Listeria detection method was developed utilizing A511 bacteriophage amplification combined with surface-enhanced Raman spectroscopy (SERS and lateral flow immunochromatography (LFI. Anti-A511 antibodies were covalently linked to SERS nanoparticles and printed onto nitrocellulose membranes. Antibody-conjugated SERS nanoparticles were used as quantifiable reporters. In the presence of A511, phage-SERS nanoparticle complexes were arrested and concentrated as a visible test line, which was interrogated quantitatively by Raman spectroscopy. An increase in SERS intensity correlated to an increase in captured phage-reporter complexes. SERS limit of detection was 6 × 106 pfu·mL−1, offering detection below that obtainable by the naked eye (LOD 6 × 107 pfu·mL−1. Phage amplification experiments were carried out at a multiplicity of infection (MOI of 0.1 with 4 different starting phage concentrations monitored over time using SERS-LFI and validated by spot titer assay. Detection of L. monocytogenes concentrations of 1 × 107 colony forming units (cfu·mL−1, 5 × 106 cfu·mL−1, 5 × 105 cfu·mL−1 and 5 × 104 cfu·mL−1 was achieved in 2, 2, 6, and 8 h, respectively. Similar experiments were conducted at a constant starting phage concentration (5 × 105 pfu·mL−1 with MOIs of 1, 2.5, and 5 and were detected in 2, 4, and 5 h, respectively.

  12. A Flow Cytometry Method for Rapidly Assessing Mycobacterium tuberculosis Responses to Antibiotics with Different Modes of Action.

    Science.gov (United States)

    Hendon-Dunn, Charlotte Louise; Doris, Kathryn Sarah; Thomas, Stephen Richard; Allnutt, Jonathan Charles; Marriott, Alice Ann Neville; Hatch, Kim Alexandra; Watson, Robert James; Bottley, Graham; Marsh, Philip David; Taylor, Stephen Charles; Bacon, Joanna

    2016-07-01

    Current methods for assessing the drug susceptibility of Mycobacterium tuberculosis are lengthy and do not capture information about viable organisms that are not immediately culturable under standard laboratory conditions as a result of antibiotic exposure. We have developed a rapid dual-fluorescence flow cytometry method using markers for cell viability and death. We show that the fluorescent marker calcein violet with an acetoxy-methyl ester group (CV-AM) can differentiate between populations of M. tuberculosis growing at different rates, while Sytox green (SG) can differentiate between live and dead mycobacteria. M. tuberculosis was exposed to isoniazid or rifampin at different concentrations over time and either dual stained with CV-AM and SG and analyzed by flow cytometry or plated to determine the viability of the cells. Although similar trends in the loss of viability were observed when the results of flow cytometry and the plate counting methods were compared, there was a lack of correlation between these two approaches, as the flow cytometry analysis potentially captured information about cell populations that were unable to grow under standard conditions. The flow cytometry approach had an additional advantage in that it could provide insights into the mode of action of the drug: antibiotics targeting the cell wall gave a flow cytometry profile distinct from those inhibiting intracellular processes. This rapid drug susceptibility testing method could identify more effective antimycobacterials, provide information about their potential mode of action, and accelerate their progress to the clinic.

  13. Color-induced graph colorings

    CERN Document Server

    Zhang, Ping

    2015-01-01

    A comprehensive treatment of color-induced graph colorings is presented in this book, emphasizing vertex colorings induced by edge colorings. The coloring concepts described in this book depend not only on the property required of the initial edge coloring and the kind of objects serving as colors, but also on the property demanded of the vertex coloring produced. For each edge coloring introduced, background for the concept is provided, followed by a presentation of results and open questions dealing with this topic. While the edge colorings discussed can be either proper or unrestricted, the resulting vertex colorings are either proper colorings or rainbow colorings. This gives rise to a discussion of irregular colorings, strong colorings, modular colorings, edge-graceful colorings, twin edge colorings and binomial colorings. Since many of the concepts described in this book are relatively recent, the audience for this book is primarily mathematicians interested in learning some new areas of graph colorings...

  14. Understanding the rapidity of subsurface storm flow response from a fracture-oriented shallow vadose through a new perspective

    Science.gov (United States)

    Zhao, Peng; Zhao, Pei; Liang, Chuan; Li, Tianyang; Zhou, Baojia

    2017-01-01

    Velocity and celerity in hydrologic systems are controlled by different mechanisms. Efforts were made through joint sample collection and the use of hydrographs and tracers to understand the rapidity of the subsurface flow response to rainstorms on hourly time scales. Three deep subsurface flows during four natural rainstorm events were monitored. The results show that (1) deeper discharge was observed early in responding rainfall events and yielded a high hydrograph amplitude; (2) a ratio index, k, reflecting the dynamic change of the rainfall perturbation intensity in subsurface flow, might reveal inner causal relationships between the flow index and the tracer signal index. Most values of k were larger than 1 at the perturbation stage but approximated 1 at the no-perturbation stage; and (3) for statistical analysis of tracer signals in subsurface flows, the total standard deviation was 17.2, 11.9, 7.4 and 3.5 at perturbation stages and 4.4, 2.5, 1.1, and 0.95 at the non-perturbation stage for observed events. These events were 3-7 times higher in the former rather than the later, reflecting that the variation of tracer signals primarily occurred under rainfall perturbation. Thus, we affirmed that the dynamic features of rainfall have a key effect on rapid processes because, besides the gravity, mechanical waves originating from dynamic rainfall features are another driving factor for conversion between different types of rainfall mechanical energy. A conceptual model for pressure wave propagation was proposed, in which virtual subsurface flow processes in a heterogeneous vadose zone under rainfall are analogous to the water hammer phenomenon in complex conduit systems. Such an analogy can allow pressure in a shallow vadose to increase and decrease and directly influence the velocity and celerity of the flow reflecting a mechanism for rapid subsurface hydrologic response processes in the shallow vadose zone.

  15. Assessment of Uterine Receptivity by Endometrial and Subendometrial Blood Flows Measured by Vaginal Color Doppler Ultrasound in Women Undergoing IVF Treatment

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Obiective To evaluate endometrial and Subendometrial blood flows measured by vaginal color Doppler ultrasound as a predicator of endometrial receptivity in women undergoing IVF treatment.Methods A total of 119 infertile patients undergoing the first IVF/ICSI-ET cycle were recruited.Three groups were divided according to a color Doppler ultrasound examination performed on the day of hCG injection.Group A,endometrial and subendometrial blood flows were 2 branches and below,group B,endometrial and subendometrial blood flows were between 3 and 4 branches;group C, endometrial and subendometrial blood flows were 5 branches and above.Patients were transferred 1-3 embryos each.Demographic data,ovarian responses.endometrial thickness,PI,RI,development of embryo and IVF result among groups were compared.Results Demographic data,ovarian responses,endometrial thickness,PI,RI and development of embryo among groups have no significant difference.The pregnancy rate of group A was significantly lower than that of group B(P<0.05) and group C(P<0.01).The implantation rate of group A was significantly lower than than of group C (P<0.01).There was no significant difference of the rate of pregnancy and implantation between group B and group C (P>0.05).Conclusion Endometrial and subendometrial blood flows measured by vaginal color Doppler ultrasound is a good predicator of pregnancy during IVF treatment.A good endometrial and subendometrial blood flows is benefit for the result of IVF.

  16. Segmented continuous-flow multiplex polymerase chain reaction microfluidics for high-throughput and rapid foodborne pathogen detection.

    Science.gov (United States)

    Shu, Bowen; Zhang, Chunsun; Xing, Da

    2014-05-15

    High-throughput and rapid identification of multiple foodborne bacterial pathogens is vital in global public health and food industry. To fulfill this need, we propose a segmented continuous-flow multiplex polymerase chain reaction (SCF-MPCR) on a spiral-channel microfluidic device. The device consists of a disposable polytetrafluoroethylene (PTFE) capillary microchannel coiled on three isothermal blocks. Within the channel, n segmented flow regimes are sequentially generated, and m-plex PCR is individually performed in each regime when each mixture is driven to pass three temperature zones, thus providing a rapid analysis throughput of m×n. To characterize the performance of the microfluidic device, continuous-flow multiplex PCR in a single segmented flow has been evaluated by investigating the effect of key reaction parameters, including annealing temperatures, flow rates, polymerase concentration and amount of input DNA. With the optimized parameters, the genomic DNAs from Salmonella enterica, Listeria monocytogenes, Escherichia coli O157:H7 and Staphylococcus aureus could be amplified simultaneously in 19min, and the limit of detection was low, down to 10(2) copiesμL(-1). As proof of principle, the spiral-channel SCF-MPCR was applied to sequentially amplify four different bacterial pathogens from banana, milk, and sausage, displaying a throughput of 4×3 with no detectable cross-contamination.

  17. Rapid and efficient copper-catalyzed Finkelstein reaction of (hetero)aromatics under continuous-flow conditions.

    Science.gov (United States)

    Chen, Mao; Ichikawa, Saki; Buchwald, Stephen L

    2015-01-01

    A general, rapid, and efficient method for the copper-catalyzed Finkelstein reaction of (hetero)aromatics has been developed using continuous flow to generate a variety of aryl iodides. The described method can tolerate a broad spectrum of functional groups, including N-H and O-H groups. Additionally, in lieu of isolation, the aryl iodide solutions were used in two distinct multistep continuous-flow processes (amidation and Mg-I exchange/nucleophilic addition) to demonstrate the flexibility of this method.

  18. Influence of 4- and 6-color flow cytometers and acquisition/analysis softwares on the determination of lymphocyte subsets in HIV infection.

    Science.gov (United States)

    Ashman, M; Sachdeva, N; Davila, L; Scott, G; Mitchell, C; Cintron, L; Rathore, M; Asthana, D

    2007-09-01

    Lymphocyte immunophenotyping provides valuable information for the diagnosis and monitoring of patients with cellular immunodeficiencies, such as HIV/AIDS. In this study, we have assessed the influence of 4-color and 6-color flow cytometers, and respective analytical softwares on the enumeration of lymphocytes in HIV infected individuals. The expression of various cell surface markers on lymphocytes was measured from the EDTA blood of 66 HIV infected patients on the FACSCalibur (4-color) and FACSCanto (6-color) flow cytometers. Percentage of lymphocytes expressing a particular cell surface marker was analyzed on FACSCalibur using the Cell Quest Pro software (v 5.2), while the analysis on FACSCanto was done using FACSCanto (v 1.0.3) and FACSDiva (v 4.1) softwares respectively. The data shows significantly higher mean CD3 T-cell counts on FACSCalibur, Cell Quest Pro (1,864 +/- 1,044 cells/microl) as compared to FACSCanto (1,840 +/- 1,040 cells/microl) (P Quest Pro (885 +/- 770 cells/microl), and FACSDiva (892 +/- 773 cells/microl) versus FACSCanto (867 +/- 767 cells/microl) (P Quest Pro, and FACSDiva showed similar values except for CD8 T-lymphocytes where FACSDiva had significantly lower values (P Quest Pro (240 +/- 165 cells/microl), and FACSDiva (238 +/- 163 cells/microl) versus FACSCanto with higher NK cell counts (260 +/- 176 cells/microl). The enumeration of lymphocyte subsets was comparable between FACSCalibur, Cell Quest Pro, and FACSDiva, based analysis and it was significantly different than FACSCanto software based analysis. Our observations suggest that FACSDiva software should be preferred over the FACSCanto software for immunophenotyping on FACSCanto flow cytometer and the laboratories should report the instrument and software used for the specimen analysis while reporting immunophenotyping results. Copyright 2007 Clinical Cytometry Society.

  19. Color-infrared composite of Landsat data for the Sarcobatus Flat area of the Death Valley regional flow system

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — The raster-based, color-infrared composite was derived from Landsat Thematic Mapper imagery data acquired during June 1989 for the Sarcobatus Flat area of the Death...

  20. Color Blindness

    Science.gov (United States)

    ... rose in full bloom. If you have a color vision defect, you may see these colors differently than most people. There are three main kinds of color vision defects. Red-green color vision defects are the most ...

  1. A multistep continuous-flow system for rapid on-demand synthesis of receptor ligands

    DEFF Research Database (Denmark)

    Petersen, Trine P; Ritzén, Andreas; Ulven, Trond

    2009-01-01

    A multistep continuous-flow system for synthesis of receptor ligands by assembly of three variable building blocks in a single unbroken flow is described. The sequence consists of three reactions and two scavenger steps, where a Cbz-protected diamine is reacted with an isocyanate, deprotected, an...

  2. Rapid Analysis of Copper Ore in Pre-Smelter Head Flow Slurry by Portable X-ray Fluorescence.

    Science.gov (United States)

    Burnett, Brandon J; Lawrence, Neil J; Abourahma, Jehad N; Walker, Edward B

    2016-05-01

    Copper laden ore is often concentrated using flotation. Before the head flow slurry can be smelted, it is important to know the concentration of copper and contaminants. The concentration of copper and other elements fluctuate significantly in the head flow, often requiring modification of the concentrations in the slurry prior to smelting. A rapid, real-time analytical method is needed to support on-site optimization of the smelter feedstock. A portable, handheld X-ray fluorescence spectrometer was utilized to determine the copper concentration in a head flow suspension at the slurry origin. The method requires only seconds and is reliable for copper concentrations of 2.0-25%, typically encountered in such slurries. © The Author(s) 2016.

  3. Rapid synthesis of propyl caffeate in ionic liquid using a packed bed enzyme microreactor under continuous-flow conditions.

    Science.gov (United States)

    Wang, Jun; Gu, Shuang-Shuang; Cui, Hong-Sheng; Yang, Liu-Qing; Wu, Xiang-Yang

    2013-12-01

    Propyl caffeate has the highest antioxidant activity among caffeic acid alkyl esters, but its industrial production via enzymatic transesterification in batch reactors is hindered by a long reaction time (24h). To develop a rapid process for the production of propyl caffeate in high yield, a continuous-flow microreactor composed of a two-piece PDMS in a sandwich-like microchannel structure was designed for the transesterification of methyl caffeate and 1-propanol catalyzed by Novozym 435 in [B mim][CF3SO3]. The maximum yield (99.5%) in the microreactor was achieved in a short period of time (2.5h) with a flow rate of 2 μL/min, which kinetic constant Km was 16 times lower than that of a batch reactor. The results indicated that the use of a continuous-flow packed bed enzyme microreactor is an efficient method of producing propyl caffeate with an overall yield of 84.0%.

  4. Wide range instantaneous temperature measurements of convective fluid flows by using a schlieren system based in color images

    Science.gov (United States)

    Martínez-González, A.; Moreno-Hernández, D.; Monzón-Hernández, D.; León-Rodríguez, M.

    2017-06-01

    In the schlieren method, the deflection of light by the presence of an inhomogeneous medium is proportional to the gradient of its refractive index. Such deflection, in a schlieren system, is represented by light intensity variations on the observation plane. Then, for a digital camera, the intensity level registered by each pixel depends mainly on the variation of the medium refractive index and the status of the digital camera settings. Therefore, in this study, we regulate the intensity value of each pixel by controlling the camera settings such as exposure time, gamma and gain values in order to calibrate the image obtained to the actual temperature values of a particular medium. In our approach, we use a color digital camera. The images obtained with a color digital camera can be separated on three different color-channels. Each channel corresponds to red, green, and blue color, moreover, each one has its own sensitivity. The differences in sensitivity allow us to obtain a range of temperature values for each color channel. Thus, high, medium and low sensitivity correspond to green, blue, and red color channel respectively. Therefore, by adding up the temperature contribution of each color channel we obtain a wide range of temperature values. Hence, the basic idea in our approach to measure temperature, using a schlieren system, is to relate the intensity level of each pixel in a schlieren image to the corresponding knife-edge position measured at the exit focal plane of the system. Our approach was applied to the measurement of instantaneous temperature fields of the air convection caused by a heated rectangular metal plate and a candle flame. We found that for the metal plate temperature measurements only the green and blue color-channels were required to sense the entire phenomena. On the other hand, for the candle case, the three color-channels were needed to obtain a complete measurement of temperature. In our study, the candle temperature was took as

  5. The energetics of flow through a rapidly oscillating tube with slowly varying amplitude.

    Science.gov (United States)

    Whittaker, Robert J; Heil, Matthias; Waters, Sarah L

    2011-07-28

    Motivated by the problem of self-excited oscillations in fluid-filled collapsible tubes, we examine the flow structure and energy budget of flow through an elastic-walled tube. Specifically, we consider the case in which a background axial flow is perturbed by prescribed small-amplitude high-frequency long-wavelength oscillations of the tube wall, with a slowly growing or decaying amplitude. We use a multiple-scale analysis to show that, at leading order, we recover the constant-amplitude equations derived by Whittaker et al. (Whittaker et al. 2010 J. Fluid Mech. 648, 83-121. (doi:10.1017/S0022112009992904)) with the effects of growth or decay entering only at first order. We also quantify the effects on the flow structure and energy budget. Finally, we discuss how our results are needed to understand and predict an instability that can lead to self-excited oscillations in collapsible-tube systems.

  6. Cross-hole tracer experiment reveals rapid fluid flow and low effective porosity in the upper oceanic crust

    Science.gov (United States)

    Neira, N. M.; Clark, J. F.; Fisher, A. T.; Wheat, C. G.; Haymon, R. M.; Becker, K.

    2016-09-01

    Numerous field, laboratory, and modeling studies have explored the flows of fluid, heat, and solutes during seafloor hydrothermal circulation, but it has been challenging to determine transport rates and flow directions within natural systems. Here we present results from the first cross-hole tracer experiment in the upper oceanic crust, using four subseafloor borehole observatories equipped with autonomous samplers to track the transport of a dissolved tracer (sulfur hexafluoride, SF6) injected into a ridge-flank hydrothermal system. During the first three years after tracer injection, SF6 was transported both north and south through the basaltic aquifer. The observed tracer transport rate of ∼2-3 m/day is orders of magnitude greater than bulk rates of flow inferred from thermal and chemical observations and calculated with coupled fluid-heat flow simulations. Taken together, these results suggest that the effective porosity of the upper volcanic crust through which much tracer was transported is <1%, with fluid flowing rapidly along a few well-connected channels. This is consistent with the heterogeneous (layered, faulted, and/or fractured) nature of the volcanic upper oceanic crust.

  7. A rapid fractionation method for heavy metals in soil by continuous-flow sequential extraction assisted by focused microwaves.

    Science.gov (United States)

    Nakazato, Tetsuya; Akasaka, Mikio; Tao, Hiroaki

    2006-11-01

    A microwave-assisted continuous-flow sequential extraction system was developed for rapid fractionation analysis of heavy metals in soil. Insertion of pressure-adjusted air between the extractants provided stable flows of the extractants without mutual mixing and back-pressure influence of a column packed with soil, thereby facilitating reliable continuous-flow extractions. In addition, use of pure water as a pumping solvent removed metal contamination because of direct contact between corrosive extractants and the pump containing metallic materials. Focused microwave irradiation to the soil accelerated the selective extractions of the acid-soluble and reducible fractions of heavy metals in soil in the first and second steps of the sequential extraction conditions, as defined by the Commission of the European Bureau of Reference (BCR). The microwave-assisted continuous-flow extraction provided high correlations in amounts of six heavy metals except Zn in the first step and Cu in the second step extracted from a reference sludge soil, BCR CRM 483, with a conventional batchwise extraction proposed by BCR; continuous-flow extraction assisted by conductive heating provided lower correlations for all the six metals. The proposed method drastically reduced the time required for the sequence extraction to ca. 65 min without losing accuracy and precision of the fractionation analysis of heavy metals in soil, whereas the BCR batchwise method requires ca. 33 h.

  8. Description and validation of a rapid (1 h) flow cytometry test for enumerating thermophilic bacteria in milk powders.

    Science.gov (United States)

    Flint, S; Walker, K; Waters, B; Crawford, R

    2007-04-01

    The aim of this study was to develop a rapid assay for enumerating thermophilic bacteria in milk powder. The BactiFlow flow cytometer was used to count bacteria based on esterase activity in viable bacterial cells. A protocol for total viable bacteria was modified by heat-treating the sample to selectively label thermophilic bacteria. Samples of milk powder dissolved in 0.1% peptone were treated with 0.8% ethylenediaminetetraacetic acid to reduce background interference because of denatured milk proteins. Either thermophilic bacteria were added to the dissolved milk powder or milk powder solutions were incubated at 55 degrees C for 2-3 h to enrich the natural thermophile population for testing. Results from the BactiFlow were compared with traditional plate count results. Thermophilic bacteria in milk powder can be enumerated within 1 h using the BactiFlow flow cytometer. Microbiological test results obtained within 1 h can potentially be used to monitor manufacturing processes, effectively trace problems and provide confidence in the manufacture of product.

  9. Suppression of high-pT particle production in AA collisions: the role of in-medium color-flow

    CERN Document Server

    Beraudo, A; Wiedemann, U A

    2011-01-01

    The suppression of high-pT single-hadron spectra in heavy-ion collisions is usually interpreted as due to parton energy-loss of high-momentum quarks and gluons propagating in the plasma. Here, we discuss to what extent this partonic picture must be complemented by a picture of medium-modified hadronization. In particular, we show how color-exchange with the medium modifies the properties of color singlet-clusters arising from the parton branchings, producing a softening of the hadron spectra.

  10. The role of in-medium color flow for high-p(T) particle production in A A collisions

    CERN Document Server

    Beraudo, A; Wiedemann, U A

    2011-01-01

    The suppression of high-p(T) single-hadron spectra in heavy-ion collisions is usually interpreted as due to parton energy loss of high-momentum quarks and gluons propagating in the plasma. Here, we discuss to what extent this partonic picture must be complemented by a picture of medium-modified hadronization. In particular, we show how color exchange with the medium modifies the properties of color-singlet clusters arising from the parton branchings, producing a softening of the hadron spectra.

  11. Rapid continuous flow synthesis of high-quality silver nanocubes and nanospheres

    KAUST Repository

    Mehenni, Hakim

    2013-01-01

    We report a biphasic-liquid segmented continuous flow method for the synthesis of high-quality plasmonic single crystal silver nanocubes and nanospheres. The nanocubes were synthesized with controllable edge lengths from 20 to 48 nm. Single crystal nanospheres with a mean size of 29 nm were obtained by in-line continuous-flow etching of as-produced 39 nm nanocubes with an aqueous solution of FeNO3. In comparison to batch synthesis, the demonstrated processes represent highly scalable reactions, in terms of both production rate and endurance. The reactions were conducted in a commercially available flow-reactor system that is easily adaptable to industrial-scale production, facilitating widespread utilization of the procedure and the resulting nanoparticles. This journal is © The Royal Society of Chemistry 2013.

  12. Particle Dynamics and Rapid Trapping in Electro-Osmotic Flow Around a Sharp Microchannel Corner

    CERN Document Server

    Zehavi, Matan

    2014-01-01

    We study here the curious particle dynamics resulting from electro-osmotic flow around a microchannel junction corner whose dielectric walls are weakly polarizable. The hydrodynamic velocity field is obtained via superposition of a linear irrotational term associated with the equilibrium zeta potentials of both the microchannel and particle surfaces and the non-linear induced-charge electro-osmotic flow which originates from the interaction of the externally applied electric field on the charge cloud it induces at the solid-liquid interface. The particle dynamics are analyzed by considering dielectrophoretic forces via the addition of a mobility term to the flow field in the limit of Stokes drag law. The former, non-divergence free term is responsible for migration of particles towards the sharp microchannel junction corner, where they can potentially accumulate. Experimental observations of particle trapping for various applied electric fields and microparticle size are rationalized in terms of the growing r...

  13. Exact two-dimensionalization of rapidly rotating large-Reynolds-number flows

    CERN Document Server

    Gallet, Basile

    2015-01-01

    We consider the flow of a Newtonian fluid in a three-dimensional domain, rotating about a vertical axis and driven by a vertically invariant horizontal body-force. This system admits vertically invariant solutions that satisfy the 2D Navier-Stokes equation. At high Reynolds number and without global rotation, such solutions are usually unstable to three-dimensional perturbations. By contrast, for strong enough global rotation, we prove rigorously that the 2D (and possibly turbulent) solutions are stable to vertically dependent perturbations: the flow becomes 2D in the long-time limit. These results shed some light on several fundamental questions of rotating turbulence: for arbitrary Reynolds number and small enough Rossby number, the system is attracted towards purely 2D flow solutions, which display no energy dissipation anomaly and no cyclone-anticyclone asymmetry. Finally, these results challenge the applicability of wave turbulence theory to describe stationary rotating turbulence in bounded domains.

  14. Laser flow microphotometry for rapid analysis and sorting of mammalian cells. [X and gamma radiation

    Energy Technology Data Exchange (ETDEWEB)

    Mullaney, P.F.; Steinkamp, J.A.; Crissman, H.A.; Cram, L.S.; Crowell, J.M.; Salzman, G.C.; Martin, J.C.; Price, B.

    1976-01-01

    Quantitative precision measurements can be made of the optical properties of individual mammalian cells using flow microphotometry. Suspended cells pass through a special flow chamber where they are lined up for exposure to blue light from an argon-ion laser. As each cell crosses the laser beam, it produces one or more optical pulses of a duration equal to cell transit time across the beam. These pulses are detected, amplified, and analyzed using the techniques of gamma ray spectroscopy. Quantitative DNA distributions made it possible to distinguish tumor cells from normal cells as well as to assay for radiation effects on tumor cells subjected to x and gamma radiation. (HLW)

  15. Color Doppler measurement of blood flow in the inferior thyroid artery in patients with autoimmune thyroid diseases

    Energy Technology Data Exchange (ETDEWEB)

    Caruso, Giuseppe; Attard, Marco; Caronia, Aurelio; Lagalla, Roberto

    2000-10-01

    Purpose: The aim of the study is to find out whether the measurement of peak systolic velocity in the inferior thyroid artery (ITA) is a valuable parameter to differentiate autoimmune thyroid diseases (hyper-, normo- or hypofunctional) and to evaluate the efficacy of medical treatment. Material and methods: The ITA of 31 patients (eight with Graves' disease, 23 with subclinical hypothyroidism) was examined with color Doppler and pulsed Doppler. The final diagnosis was obtained by citology and by hormonal and antibodies assays. The patients were monitorized by ultrasound for a period of 8 months. Results: In all the patients with Graves' disease the peak systolic velocity was always over 150 cm/s, while in other autoimmune thyroiditis the peak systolic velocity was within the normal range, and never exceeding 65 cm/s. In the first group, the measurement taken in the ITA showed also the efficacy of the pharmacological treatment earlier and more reliably than the color Doppler pattern obtained in the parenchyma. Conclusions: The color Doppler measurement of the ITA seems to be a promising technique with low-cost and easy approach. In our experience, the color Doppler of the ITA could have a clinical role in the differential diagnosis of diffuse thyroid diseases and in the follow-up of the Graves' disease during medical treatment.

  16. Elliptic flow at forward rapidity in the square root of sNN = 200 GeV gold + gold collisions

    Science.gov (United States)

    Richardson, Eric Michael

    Forward rapidity elliptic flow (v2) of both unidentified charged hadrons and decay muons has been measured from sNN = 200 GeV Au+Au collisions as a function of pseudorapidity (η), transverse momentum, and number of nucleon collision participants. The measurements were performed at Brookhaven National Laboratory's Relativistic Heavy Ion Collider using the PHENIX experiment's Muon Arm spectrometers, located at 1.2 BRAHMS measurements (η ≈ 3) is a v2 suppression seen for central collisions. For increasingly peripheral collisions, a growing suppression in v2 is observed for the Muon Arm measurements compared to mid-rapidity, indicating increased changes in the medium properties of ever smaller systems. For peripheral collisions of the same/similar centralities, an increased suppression is observed toward forward η.

  17. Flow induced dispersion analysis rapidly quantifies proteins in human plasma samples

    DEFF Research Database (Denmark)

    Poulsen, Nicklas N; Andersen, Nina Z; Østergaard, Jesper;

    2015-01-01

    to cumbersome and expensive assay development. In this work a new approach for quantification based on changes in diffusivity is presented. The apparent diffusivity of an indicator molecule interacting with the protein of interest is determined by Taylor Dispersion Analysis (TDA) in a hydrodynamic flow system...

  18. Rapid and enhanced activation of microporous coordination polymers by flowing supercritical CO.sub.2

    Science.gov (United States)

    Matzger, Adam J.; Liu, Baojian; Wong-Foy, Antek G.

    2016-07-19

    Flowing supercritical CO.sub.2 is used to activate metal organic framework materials (MOF). MOFs are activated directly from N,N-dimethylformamide (DMF) thus avoiding exchange with a volatile solvent. Most MCPs display increased surface areas directly after treatment although those with coordinatively unsaturated metal centers benefit from additional heating.

  19. A hybrid CFD-DSMC model designed to simulate rapidly rarefying flow fields and its application to physical vapor deposition

    Science.gov (United States)

    Gott, Kevin

    This research endeavors to better understand the physical vapor deposition (PVD) vapor transport process by determining the most appropriate fluidic model to design PVD coating manufacturing. An initial analysis was completed based on the calculation of Knudsen number from titanium vapor properties. The results show a dense Navier-Stokes solver best describes flow near the evaporative source, but the material properties suggest expansion into the chamber may result in a strong drop in density and a rarefied flow close to the substrate. A hybrid CFD-DSMC solver is constructed in OpenFOAM for rapidly rarefying flow fields such as PVD vapor transport. The models are patched together combined using a new patching methodology designed to take advantage of the one-way motion of vapor from the CFD region to the DSMC region. Particles do not return to the dense CFD region, therefore the temperature and velocity can be solved independently in each domain. This novel technique allows a hybrid method to be applied to rapidly rarefying PVD flow fields in a stable manner. Parameter studies are performed on a CFD, Navier-Stokes continuum based compressible solver, a Direct Simulation Monte Carlo (DSMC) rarefied particle solver, a collisionless free molecular solver and the hybrid CFD-DSMC solver. The radial momentum at the inlet and radial diffusion characteristics in the flow field are shown to be the most important to achieve an accurate deposition profile. The hybrid model also shows sensitivity to the shape of the CFD region and rarefied regions shows sensitivity to the Knudsen number. The models are also compared to each other and appropriate experimental data to determine which model is most likely to accurately describe PVD coating deposition processes. The Navier-Stokes solvers are expected to yield backflow across the majority of realistic inlet conditions, making their physics unrealistic for PVD flow fields. A DSMC with improved collision model may yield an accurate

  20. Forward-rapidity azimuthal and radial flow of identified particles for s=200 GeV Au+Au collisions

    Science.gov (United States)

    Brahms Collaboration; Sanders, S. J.; BRAHMS Collaboration

    2009-11-01

    A strong azimuthal flow signature at RHIC suggests rapid system equilibration leading to an almost perfect fluid state. The longitudinal extent of the flow behavior depends on how this state is formed and can be studied by measuring the pseudorapidity and transverse momentum dependence of the second Fourier component (ν(p)) of the azimuthal angular distribution. We report on a measurement of identified-particle ν as a function of p(0.5-2.0 GeV/c), centrality (0-25%, 25-50%), and pseudorapidity (0⩽ηBRAHMS spectrometers are used for particle identification (π, K, p) and momentum determination and the BRAHMS global detectors are used to determine the corresponding reaction-plane angles. The results are discussed in terms of the pseudorapidity dependence of constituent quark scaling and in terms of models that develop the complete (azimuthal and radial) hydrodynamic aspects of the forward dynamics at RHIC.

  1. Rapid Sedimentation, Overpressure, and Focused Fluid Flow, Gulf of Mexico Continental Margin

    Directory of Open Access Journals (Sweden)

    Cédric M. John

    2006-09-01

    Full Text Available Expedition 308 of the Integrated Ocean Drilling Program (IODP was the fi rst phase of a two-component project dedicated to studying overpressure and fl uid fl ow on the continental slope of the Gulf of Mexico. We examined how sedimentation, overpressure, fl uid fl ow, and deformation are coupled in a passive margin setting and investigated how extremely rapid deposition of fi ne-grained mud might lead to a rapid build-up of pore pressure in excess of hydrostatic (overpressure, underconsolidation, and sedimentary masswasting. Our tests within the Ursa region, where sediment accumulated rapidly in the late Pleistocene, included the first-ever in situ measurements of how physical properties, pressure, temperature,and pore fluid compositions vary within low-permeability mudstones that overlie a permeable, overpressured aquifer, and we documented severe overpressure in the mudstones overlying the aquifer. We also drilled and logged three references sites in the Brazos-Trinity Basin IV and documented hydrostatic pressure conditions and normalconsolidation. Post-expedition studies will address how the generation and timing of overpressure control slope stability, seafl oor seeps, and large-scale crustal fluid fl ow. The operations ofExpedition 308 provide a foundation for future long-term in situ monitoring experiments in the aquifer and bounding mudstones.

  2. Rapid and sensitive lateral flow immunoassay method for determining alpha fetoprotein in serum using europium (III) chelate microparticles-based lateral flow test strips.

    Science.gov (United States)

    Liang, Rong-Liang; Xu, Xu-Ping; Liu, Tian-Cai; Zhou, Jian-Wei; Wang, Xian-Guo; Ren, Zhi-Qi; Hao, Fen; Wu, Ying-Song

    2015-09-01

    Alpha-fetoprotein (AFP), a primary marker for many diseases including various cancers, is important in clinical tumor diagnosis and antenatal screening. Most immunoassays provide high sensitivity and accuracy for determining AFP, but they are expensive, often complex, time-consuming procedures. A simple and rapid point-of-care system that integrates Eu (III) chelate microparticles with lateral flow immunoassay (LFIA) has been developed to determine AFP in serum with an assay time of 15 min. The approach is based on a sandwich immunoassay performed on lateral flow test strips. A fluorescence strip reader was used to measure the fluorescence peak heights of the test line (HT) and the control line (HC); the HT/HC ratio was used for quantitation. The Eu (III) chelate microparticles-based LFIA assay exhibited a wide linear range (1.0-1000 IU mL(-1)) for AFP with a low limit of detection (0.1 IU mL(-1)) based on 5ul of serum. Satisfactory specificity and accuracy were demonstrated and the intra- and inter-assay coefficients of variation (CV) for AFP were both chelate microparticles-based LFIA system provided a rapid, sensitive and reliable method for determining AFP in serum, indicating that it would be suitable for development in point-of-care testing.

  3. Evaluation of the treatment performance of lab-scaled vertical flow constructed wetlands in removal of organic compounds, color and nutrients in azo dye-containing wastewater.

    Science.gov (United States)

    Dogdu, Gamze; Yalcuk, Arda

    2016-01-01

    The objective of this study is to examine the treatment performance of vertical flow intermittent feeding constructed wetland (VFCW) in removal of organic pollution, nutrients and color in azo-dye containing wastewater. The systems consisted of PVC reactors, some filling materials such as gravel, sand and zeolite and wetland plants including Typha angustifolia and Canna indica. The average treatment efficiency of the systems for COD, color, sulphate, NH4-N, and PO4-P were in the range of 57-63%, 94-99%, 44-48%, 39-44%, and 84-88%, respectively among the VFCW reactors. It is concluded that VFCW reactor system can effectively be used in the treatment of dye-rich wastewater, especially for the removal of color and in the reduction of COD. Biofilm formation and cleavage of azo bonds could be observed by SEM and FTIR results, respectively. Almost similar NH4-N and PO4-P removal were obtained in all reactors by using same amount of zeolite media.

  4. Flow injection based microfluidic device with carbon nanotube electrode for rapid salbutamol detection.

    Science.gov (United States)

    Karuwan, Chanpen; Wisitsoraat, Anurat; Maturos, Thitima; Phokharatkul, Disayut; Sappat, Assawapong; Jaruwongrungsee, Kata; Lomas, Tanom; Tuantranont, Adisorn

    2009-09-15

    A microfabicated flow injection device has been developed for in-channel electrochemical detection (ECD) of a beta-agonist, namely salbutamol. The microfluidic system consists of PDMS (polydimethylsiloxane) microchannel and electrochemical electrodes formed on glass substrate. The carbon nanotube (CNT) on gold layer as working electrode, silver as reference electrode and platinum as auxiliary electrode were deposited on a glass substrate. Silver, platinum, gold and stainless steel catalyst layers were coated by DC-sputtering. CNTs were then grown on the glass substance by thermal chemical vapor deposition (CVD) with gravity effect and water-assisted etching. 100-microm-deep and 500-microm-wide PDMS microchannels fabricated by SU-8 molding and casting were then bonded on glass substrate by oxygen plasma treatment. Flow injection and ECD of salbutamol was performed with the amperometric detection mode for in-channel detection of salbutamol. The influences of flow rate, injection volume, and detection potential on the response of current signal were optimized. Analytical characteristics, such as sensitivity, repeatability and dynamic range have been evaluated. Fast and highly sensitive detection of salbutamol have been achieved. Thus, the proposed combination of the efficient CNT electrode and miniaturized lab-on-a-chip is a powerful platform for beta-agonists detection.

  5. Human regional cerebral blood flow during rapid-eye-movement sleep

    DEFF Research Database (Denmark)

    Madsen, P L; Holm, S; Vorstrup, S;

    1991-01-01

    Owing to the coupling between CBF and neuronal activity, regional CBF is a reflection of neural activity in different brain regions. In this study we measured regional CBF during polysomnographically well-defined rapid-eye-movement (REM) sleep by the use of single photon emission computerized...... tomography and the new tracer 99mTc-dl-hexamethylpropyleneamine. Eleven healthy volunteers aged between 22 and 27 years were studied. CBF was measured on separate nights during REM sleep and during EEG-verified wakefulness. On awakening from REM sleep, all subjects reported visual dreams. During REM sleep...

  6. Development of an immunochromatographic lateral flow device for rapid diagnosis of Vibrio cholerae O1 serotype Ogawa.

    Science.gov (United States)

    Chen, Weixian; Zhang, Jun; Lu, Gang; Yuan, Zuowei; Wu, Qian; Li, Jingjing; Xu, Guiping; He, An; Zheng, Jian; Zhang, Juan

    2014-04-01

    Cholera is an acute malignant infectious disease caused by the bacteria Vibrio cholerae leading to severe dehydrating diarrhea and vomiting, even high rates of mortality in some cases. However, the prevention of the epidemic disease is achievable if proper sanitation practices are followed, provided the accurate and prompt diagnosis of each prevalent serotype in cholera epidemic. The current gold standard of bacterial culture is inadequate for rapid diagnosis. Our aim is to develop an immunochromatographic test format for O1 serotype Ogawa diagnosis and provide the need for better epidemic prevention and early response. The monoclonal antibodies were raised in conventional method and subsequently screened for a match pair. A variety of related and unrelated bacteria strains recruited were employed to test their sensitivity, specificity etc. by indirect ELISA. The human fecal samples were used to test the final lateral-flow device product to satisfy the measurement requirement. A new monoclonal antibody (McAb) pair, named IXiao₃G₆ and IXiao₁D₉, was generated, which is specifically against V. cholerae O1 serotype Ogawa. Additionally, we developed an immunochromatographic lateral flow device (LFD) using this McAb pair for the highly specific and rapid (5 min) detection of Ogawa. Our product has advantages of simplicity and precision, and can benefit the scene and elementary medical institutions. Copyright © 2013 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  7. An aptamer based lateral flow strip for on-site rapid detection of ochratoxin A in Astragalus membranaceus.

    Science.gov (United States)

    Zhou, Weilu; Kong, Weijun; Dou, Xiaowen; Zhao, Ming; Ouyang, Zhen; Yang, Meihua

    2016-06-01

    An aptamer based lateral flow strip based on competitive format was developed for on-site rapid detection of ochratoxin A (OTA) in Astragalus membranaceus. Some crucial parameters that might influence the sensitive detection, such as the characterization of the colloidal gold, size and shape of gold nanoparticles (AuNPs), amount of AuNPs-aptamer conjugate, migration rate and the addition amount of methanol, were investigated to provide the optimum assay performance. To perform the test, 1g sample was extracted with 2.5mL of methanol-water (80:20, v/v) and diluted by 4-fold running buffer to eliminate the matrix and methanol interferences. Under optimized conditions, the aptamer-based assay showed a visual limit of detection (LOD) of 1ngmL(-1), and with no significant cross-reactivity with several homologous toxins. The whole detection could be completed within 15min without special equipment because of available visual results. One out of nine A. membranaceus samples was found to be positive of OTA, which was in a good agreement with those obtained from LC-MS/MS analysis. The results demonstrated that the aptamer-based lateral flow assay could be used as a rapid, reliable, cost-effective and robust on-site screening technique for mycotoxins at trace level in complex matrices without special instrumentation.

  8. Multiparametric flow cytometry allows rapid assessment and comparison of lactic acid bacteria viability after freezing and during frozen storage.

    Science.gov (United States)

    Rault, Aline; Béal, Catherine; Ghorbal, Sarrah; Ogier, Jean-Claude; Bouix, Marielle

    2007-08-01

    Freezing is widely used for the long-term preservation of lactic acid bacteria, but often affects their viability and technological properties. Different methods are currently employed to determine bacterial cryotolerance, but they all require several hours or days before achieving results. The aim of this study was to establish the advantages of multiparametric flow cytometry by using two specific fluorescent probes to provide rapid assessment of the viability of four strains of Lactobacillus delbrueckii after freezing and during frozen storage. The relevance of carboxyfluorescein diacetate and propidium iodide to quantify bacterial viability was proven. When bacterial suspensions were simultaneously stained with these two fluorescent probes, three major subpopulations were identified: viable, dead and injured cells. The cryotolerance of four L. delbrueckii strains was evaluated by quantifying the relative percentages of each subpopulation before and after freezing, and throughout one month of storage at -80 degrees C. Results displayed significant differences in the resistance to freezing and frozen storage of the four strains when they were submitted to the same freezing and storage procedures. Whereas resistant strains displayed less than 10% of dead cells after one month of storage, one sensitive strain exhibited more than 50% of dead cells, together with 14% of stressed cells after freezing. Finally, this study proved that multiparametric flow cytometry was a convenient and rapid tool to evaluate the viability of lactic acid bacteria, and was well correlated with plate count results. Moreover, it made it possible to differentiate strains according to their susceptibility to freezing and frozen storage.

  9. Validation of color Doppler ultrasonography for evaluating the uterine blood flow and perfusion during late normal pregnancy and uterine torsion in buffaloes.

    Science.gov (United States)

    Hussein, Hassan A

    2013-04-15

    The aim of this study was to verify the efficacy of color Doppler ultrasonography for diagnosis of degree and duration of uterine torsion in buffaloes. In Assiut province/Upper Egypt, 65 buffaloes (37 with uterine torsion, 28 with normal late pregnancy) were examined clinically and using Doppler ultrasonography. The Doppler indices including resistance index (RI), pulsatility index (PI), time-averaged maximum velocity (TAMV), and blood flow volume (BFV) in the arteries ipsilateral to the uterine torsion (IPUT) and in arteries contralateral to the uterine torsion (COUT) were recorded. Methods of correction were documented along with dam and calf survival. Torsion was recorded postcervically with vaginal involvement in 35/37 (94.6%) of the cases. The degrees of uterine torsion were light and high in 9/37 (24.3%) and 28/37 (75.7%) of the cases, respectively (P = 0.001). Right uterine torsion was present in 36/37 (97.3%) of the cases (P = 0.0001). Pulsatility index, RI, TAMV, and BFV in IPUT and COUT did not differ significantly (P > 0.05) in normal late pregnancy. The PI and RI in IPUT were significantly higher (P perfusion. In conclusion, depicting blood flow within the middle uterine artery using color Doppler sonography could be helpful in correct diagnosis of duration and degree of uterine torsion and concurrently predicting the viability of the fetus and dam.

  10. [Calculation of the mitral valve area with the proximal convergent flow method with Doppler-color in patients with mitral stenosis].

    Science.gov (United States)

    Aguilar, J A; Summerson, C; Flores, D; Espinosa, R A; Enciso, R; Badui, E; Hurtado, R

    1994-01-01

    In this study we evaluate prospectively a new color Doppler method for calculating the mitral valve area based on identifying a blue-red aliasing interfase proximal to the orifice, corresponding to the flow convergence region (FCR). This method can be used to calculate areas using the continuity equation. We studied 61 patients with stenosis. The mitral valve area was calculated using pressure half-time (PHT) Doppler method which were compared with values that obtained by the FCR method, according to the following formula. AVM (cm2) = 2 pi r2 x VN/Vmax; where "r" is the FCR radius measured from the orifice to the first color aliasing (blue-red interface); VN is Nyquist velocity and Vmax is the peak flow velocity by continuous wave Doppler. Twenty three patients had pure mitral stenosis and 38 double mitral lesion. Twenty patients were on sinus rhythm while 41 in atrial fibrillation. Calculated mitral valve area using the FCR method correlated well with mitral valve area determined by PHT method at a correlation coefficient of r = 0.96 (y = 0.097 x + 54.9, SEE = 0.10 cm2, p < 0.001). MVA by FCR ranged from 0.4 to 2.5 cm2 (mean = 1.19 cm2). MVA by PHT ranged from 0.42 to 2.48 cm2 (mean = 1.15 cm2). Color Doppler FCR method provides an accurate estimate of effective mitral valve area and may be useful as an alternative to the pressure half-time method. The calculated mitral valve area by the FCR method is not influenced by the presence of mitral regurgitation nor atrial fibrillation.

  11. Assessment value of blood flow velocity and resistance index detection by transvaginal color Doppler ultrasound on effect of neoadjuvant chemotherapy for ovarian cancer

    Institute of Scientific and Technical Information of China (English)

    You-Bin Fan

    2016-01-01

    Objective:To analyze the assessment value of blood flow velocity and resistance index detection by transvaginal color Doppler ultrasound on effect of neoadjuvant chemotherapy for ovarian cancer.Methods:A total of 78 cases of ovarian cancer patients receiving treatment in our hospital from September 2012 to May 2014 were included for study, all patients received neoadjuvant chemotherapy, and before and after treatment, transvaginal color Doppler ultrasound (TVCDU) was used to record resistance index (RI) and pulsatility index (PI), the expression levels of serum tumor markers, illness-related indicators and apoptosis-related factors in circulating blood were detected, and the correlation between TVCDU monitoring indexes and ovarian cancer-related indicators was further analyzed.Results: PI value (1.13±0.12) and RI value (0.65±0.05) of ovarian cancer patients after treatment were significantly higher than PI value (0.72±0.06) and RI value (0.32±0.03) of ovarian cancer patients before treatment; serum HE4, CA153, CA125 and毬-HCG levels of ovarian cancer patients after treatment were lower than those before treatment; serum MSLN, CCL-18, FS, CL and Hpa levels of ovarian cancer patients after treatment were lower than those before treatment; after ovarian cancer patients received neoadjuvant chemotherapy, ADM, HIF-1毩, PCNA and bcl-2 gene expression levels were lower than those before treatment; RI and PI values of ovarian cancer patients were inversely proportional to the expression levels of HE4, CA153, CA125,毬-HCG, MSLN, CCL-18, FS, CL, Hpa, ADM, HIF-1毩, PCNA and bcl-2. Conclusion:Blood flow velocity and resistance index detection by transvaginal color Doppler ultrasound can be used as a highly efficient means to evaluate the effect of neoadjuvant chemotherapy for ovarian cancer, and it has positive significance in judging disease severity, guiding treatment and other aspects.

  12. The role of event water, a rapid shallow flow component, and catchment size in summer stormflow

    Science.gov (United States)

    Brown, V.A.; McDonnell, Jeffery J.; Burns, Douglas A.; Kendall, C.

    1999-01-01

    Seven nested headwater catchments (8 to 161 ha) were monitored during five summer rain events to evaluate storm runoff components and the effect of catchment size on water sources. Two-component isotopic hydrograph separation showed that event-water contributions near the time of peakflow ranged from 49% to 62% in the 7 catchments during the highest intensity event. The proportion of event water in stormflow was greater than could be accounted for by direct precipitation onto saturated areas. DOC concentrations in stormflow were strongly correlated with stream 18O composition. Bivariate mixing diagrams indicated that the large event water contributions were likely derived from flow through the soil O-horizon. Results from two-tracer, three-component hydrograph separations showed that the throughfall and O-horizon soil-water components together could account for the estimated contributions of event water to stormflow. End-member mixing analysis confirmed these results. Estimated event-water contributions were inversely related to catchment size, but the relation was significant for only the event with greatest rainfall intensity. Our results suggest that perched, shallow subsurface flow provides a substantial contribution to summer stormflow in these small catchments, but the relative contribution of this component decreases with catchment size.Seven nested headwater catchments (8 to 161 ha) were monitored during five summer rain events to evaluate storm runoff components and the effect of catchment size on water sources. Two-component isotopic hydrograph separation showed that event-water contributions near the time of peakflow ranged from 49% to 62% in the 7 catchments during the highest intensity event. The proportion of event water in stormflow was greater than could be accounted for by direct precipitation onto saturated areas. DOC concentrations in stormflow were strongly correlated with stream 18O composition. Bivariate mixing diagrams indicated that the

  13. Ice flow dynamics forced by rapid water pressure variations in subglacial granular beds

    DEFF Research Database (Denmark)

    Damsgaard, Anders; Egholm, David Lundbek; Beem, Lucas H.;

    2016-01-01

    mechanical processes driving transitions from stability to slip. We performed computational experiments that show how rearrangements of load-bearing force chains within the granular sediments drive the mechanical transitions. Cyclic variations in pore water pressure give rise to rate-dependent creeping......Glaciers and ice streams can move by deforming underlying water-saturated sediments, and the nonlinear mechanics of these materials are often invoked as the main reason for initiation, persistence, and shutdown of fast-flowing ice streams. Existing models have failed to fully explain the internal...

  14. Rapid and selective detection of experimental snake envenomation - Use of gold nanoparticle based lateral flow assay.

    Science.gov (United States)

    Pawade, Balasaheb S; Salvi, Nitin C; Shaikh, Innus K; Waghmare, Arun B; Jadhav, Nitin D; Wagh, Vishal B; Pawade, Abhilasha S; Waykar, Indrasen G; Potnis-Lele, Mugdha

    2016-09-01

    In this study, we have developed a gold nanoparticle based simple, rapid lateral flow assay (LFA) for detection of Indian Cobra venom (CV) and Russell's viper venom (RV). Presently, there is no rapid, reliable, and field diagnostic test available in India, where snake bite cases are rampant. Therefore, this test has an immense potential from the public health point of view. The test is based on the principle of the paper immunochromatography assay for detection of two snake venom species using polyvalent antisnake venom antibodies (ASVA) raised in equines and species-specific antibodies (SSAbs) against venoms raised in rabbits for conjugation and impregnation respectively. The developed, snake envenomation detection immunoassay (SEDIA) was rapid, selective, and sensitive to detect venom concentrations up to 0.1 ng/ml. The functionality of SEDIA strips was confirmed by experimental envenomation in mice and the results obtained were specific for the corresponding venom. The SEDIA has a potential to be a field diagnostic test to detect snake envenomation and assist in saving lives of snakebite victims.

  15. Bed Evolution under Rapidly Varying Flows by a New Method for Wave Speed Estimation

    Directory of Open Access Journals (Sweden)

    Khawar Rehman

    2016-05-01

    Full Text Available This paper proposes a sediment-transport model based on coupled Saint-Venant and Exner equations. A finite volume method of Godunov type with predictor-corrector steps is used to solve a set of coupled equations. An efficient combination of approximate Riemann solvers is proposed to compute fluxes associated with sediment-laden flow. In addition, a new method is proposed for computing the water depth and velocity values along the shear wave. This method ensures smooth solutions, even for flows with high discontinuities, and on domains with highly distorted grids. The numerical model is tested for channel aggradation on a sloping bottom, dam-break cases at flume-scale and reach-scale with flat bottom configurations and varying downstream water depths. The proposed model is tested for predicting the position of hydraulic jump, wave front propagation, and for predicting magnitude of bed erosion. The comparison between results based on the proposed scheme and analytical, experimental, and published numerical results shows good agreement. Sensitivity analysis shows that the model is computationally efficient and virtually independent of mesh refinement.

  16. The Use of Surveillance Cameras for the Rapid Mapping of Lava Flows: An Application to Mount Etna Volcano

    Directory of Open Access Journals (Sweden)

    Mauro Coltelli

    2017-02-01

    Full Text Available In order to improve the observation capability in one of the most active volcanic areas in the world, Mt. Etna, we developed a processing method to use the surveillance cameras for a quasi real-time mapping of syn-eruptive processes. Following an evaluation of the current performance of the Etna permanent ground NEtwork of Thermal and Visible Sensors (Etna_NETVIS, its possible implementation and optimization was investigated to determine the locations of additional observation sites to be rapidly set up during emergencies. A tool was then devised to process time series of ground-acquired images and extract a coherent multi-temporal dataset of georeferenced map. The processed datasets can be used to extract 2D features such as evolution maps of active lava flows. The tool was validated on ad-hoc test fields and then adopted to map the evolution of two recent lava flows. The achievable accuracy (about three times the original pixel size and the short processing time makes the tool suitable for rapidly assessing lava flow evolutions, especially in the case of recurrent eruptions, such as those of the 2011–2015 Etna activity. The tool can be used both in standard monitoring activities and during emergency phases (eventually improving the present network with additional mobile stations when it is mandatory to carry out a quasi-real-time mapping to support civil protection actions. The developed tool could be integrated in the control room of the Osservatorio Etneo, thus enabling the Etna_NETVIS for mapping purposes and not only for video surveillance.

  17. Rapid and sensitive lateral flow immunoassay method for determining alpha fetoprotein in serum using europium (III) chelate microparticles-based lateral flow test strips

    Energy Technology Data Exchange (ETDEWEB)

    Liang, Rong-Liang; Xu, Xu-Ping; Liu, Tian-Cai; Zhou, Jian-Wei; Wang, Xian-Guo; Ren, Zhi-Qi [Institute of Antibody Engineering, School of Biotechnology, Southern Medical University, Guangzhou 510515, Guangdong (China); Hao, Fen [DaAn Gene Co. Ltd. of Sun Yat-sen University, 19 Xiangshan Road, Guangzhou 510515 (China); Wu, Ying-Song, E-mail: wg@smu.edu.cn [Institute of Antibody Engineering, School of Biotechnology, Southern Medical University, Guangzhou 510515, Guangdong (China)

    2015-09-03

    Alpha-fetoprotein (AFP), a primary marker for many diseases including various cancers, is important in clinical tumor diagnosis and antenatal screening. Most immunoassays provide high sensitivity and accuracy for determining AFP, but they are expensive, often complex, time-consuming procedures. A simple and rapid point-of-care system that integrates Eu (III) chelate microparticles with lateral flow immunoassay (LFIA) has been developed to determine AFP in serum with an assay time of 15 min. The approach is based on a sandwich immunoassay performed on lateral flow test strips. A fluorescence strip reader was used to measure the fluorescence peak heights of the test line (H{sub T}) and the control line (H{sub C}); the H{sub T}/H{sub C} ratio was used for quantitation. The Eu (III) chelate microparticles-based LFIA assay exhibited a wide linear range (1.0–1000 IU mL{sup −1}) for AFP with a low limit of detection (0.1 IU mL{sup −1}) based on 5ul of serum. Satisfactory specificity and accuracy were demonstrated and the intra- and inter-assay coefficients of variation (CV) for AFP were both <10%. Furthermore, in the analysis of human serum samples, excellent correlation (n = 284, r = 0.9860, p < 0.0001) was obtained between the proposed method and a commercially available CLIA kit. Results indicated that the Eu (III) chelate microparticles-based LFIA system provided a rapid, sensitive and reliable method for determining AFP in serum, indicating that it would be suitable for development in point-of-care testing. - Highlights: • Europium (III) chelate microparticles was used as a label for LIFA. • Quantitative detection by using H{sub T}/H{sub C} ratio was achieved. • LIFA for simple and rapid AFP detection in human serum. • The sensitivity and linearity was more excellent compared with QD-based ICTS. • This method could be developed for rapid point-of-care screening.

  18. Dynamic egg color mimicry.

    Science.gov (United States)

    Hanley, Daniel; Šulc, Michal; Brennan, Patricia L R; Hauber, Mark E; Grim, Tomáš; Honza, Marcel

    2016-06-01

    Evolutionary hypotheses regarding the function of eggshell phenotypes, from solar protection through mimicry, have implicitly assumed that eggshell appearance remains static throughout the laying and incubation periods. However, recent research demonstrates that egg coloration changes over relatively short, biologically relevant timescales. Here, we provide the first evidence that such changes impact brood parasite-host eggshell color mimicry during the incubation stage. First, we use long-term data to establish how rapidly the Acrocephalus arundinaceus Linnaeus (great reed warbler) responded to natural parasitic eggs laid by the Cuculus canorus Linnaeus (common cuckoo). Most hosts rejected parasitic eggs just prior to clutch completion, but the host response period extended well into incubation (~10 days after clutch completion). Using reflectance spectrometry and visual modeling, we demonstrate that eggshell coloration in the great reed warbler and its brood parasite, the common cuckoo, changes rapidly, and the extent of eggshell color mimicry shifts dynamically over the host response period. Specifically, 4 days after being laid, the host should notice achromatic color changes to both cuckoo and warbler eggs, while chromatic color changes would be noticeable after 8 days. Furthermore, we demonstrate that the perceived match between host and cuckoo eggshell color worsened over the incubation period. These findings have important implications for parasite-host coevolution dynamics, because host egg discrimination may be aided by disparate temporal color changes in host and parasite eggs.

  19. Rapid detection of Bacillus anthracis spores using a super-paramagnetic lateral-flow immunological detection system.

    Science.gov (United States)

    Wang, Dian-Bing; Tian, Bo; Zhang, Zhi-Ping; Deng, Jiao-Yu; Cui, Zong-Qiang; Yang, Rui-Fu; Wang, Xu-Ying; Wei, Hong-Ping; Zhang, Xian-En

    2013-04-15

    There is an urgent need for convenient, sensitive, and specific methods to detect the spores of Bacillus anthracis, the causative agent of anthrax, because of the bioterrorism threat posed by this bacterium. In this study, we firstly develop a super-paramagnetic lateral-flow immunological detection system for B. anthracis spores. This system involves the use of a portable magnetic assay reader, super-paramagnetic iron oxide particles, lateral-flow strips and two different monoclonal antibodies directed against B. anthracis spores. This detection system specifically recognises as few as 400 pure B. anthracis spores in 30 min. This system has a linear range of 4×10³-10⁶ CFU ml⁻¹ and reproducible detection limits of 200 spores mg⁻¹ milk powder and 130 spores mg⁻¹ soil for simulated samples. In addition, this approach shows no obvious cross-reaction with other related Bacillus spores, even at high concentrations, and has no significant dependence on the duration of the storage of the immunological strips. Therefore, this super-paramagnetic lateral-flow immunological detection system is a promising tool for the rapid and sensitive detection of Bacillus anthracis spores under field conditions.

  20. Serial color Doppler flow of uterine vasculature combined with serum beta-hCG measurements for improved monitoring of patients with gestational trophoblastic disease. A preliminary report.

    Science.gov (United States)

    Maymon, R; Schneider, D; Shulman, A; Bukowsky, I; Weinraub, Z

    1996-01-01

    Weekly serum beta-hCG measurements and transvaginal ultrasound scans coupled with color Doppler flow were performed on 8 patients with hydatidiform mole. Two patients later developed persistent trophoblastic disease, necessitating chemotherapy. The correlation coefficients between Doppler flow indices, systolic-diastolic (S/D) ratio and pulsatility index (PI) with log beta-hCG were -0.96 and -0.97, respectively. The weekly S/D and PI indices were plotted on an individual curve. Only the 2 patients who developed persistent gestational trophoblastic disease had PI index levels of < or = 1.5 as early as 2 weeks after molar evacuation. At that stage their serum beta-hCG levels were not different from some of the other patients. In this preliminary report, the regression of the disease could be reliably assessed by observing the changes in low resistance flow which paralleled the gradual decrements in serial beta-hCG levels. Thus, the contribution of this noninvasive imaging technique encourages the authors to further investigate Doppler flow monitoring among a larger sample of patients suffering from various gestational trophoblastic diseases.

  1. 彩色直方图估测前列腺血流的价值%Evaluation Prostatic Flow with Color Histogram

    Institute of Scientific and Technical Information of China (English)

    陈亚青; 周永昌; 黄慕民; 唐天雪; 张惠箴; 陈洁晴

    2001-01-01

    Objective:To set relative reference data of normal and abnormal prostatic color flow with color histogram and to discuss the role in the diagnosis of prostatic diseases.Methods:Twenty-five patients with benign prostatic hypertrophy(BPH)and twenty-five with prostatic carcinoma(PCa)were measured by color histogram with two types of transrectal probe(endfire and biplane),and twenty-two normal cases were as the control group.Results:There were significant differences in the mean BCR among three groups,and there was no significant difference between the two types of the probe.However,there was overlap on individuals in each group,the overlap range was 17%~26%,74%~83% with no overlap.Conclusions:Measurements of Prostatic blood flow with color histogram can become one of the objective parameters for diagnosis of prostatic diseases.%目的:本文利用彩色直方图对正常和异常前列腺彩色血流给出定量参考值并探讨其对前列腺疾病诊断的价值。方法:分别用端射式和双平面二种探头对经穿刺活检证实的前列腺增生症和前列腺癌各25例用彩色直方图软件测得前列腺内彩色血流面积占前列腺面积的百分比(BCR),并有22例正常对照。结果:正常组、前列腺增生症组、前列腺癌组之间BCR的均值在统计学上有显著意义(端射式P<0.05;双平面P<0.01),二种探头之间无统计学意义(P>0.05)。但对个体而言各组间存在一定交叉,其交叉范围为17%~26%,不交叉范围为74%~83%。结论:彩色直方图测定前列腺血流方法可作为前列腺疾病诊断中客观的参考依据。

  2. Color Blindness

    Institute of Scientific and Technical Information of China (English)

    严双红

    2007-01-01

    About one in 12 boys is color-blind, and one in every 400 girls, so in each school class there are likely to be at least one or two people who are color-blind. Because they are color- blind from birth, most people do not know that they are color-

  3. Investigations of non-hydrostatic, stably stratified and rapidly rotating flows

    CERN Document Server

    Nieves, David; Juilen, Keith; Weiss, Jeffrey B

    2016-01-01

    We present an investigation of rapidly rotating (small Rossby number $Ro\\ll 1$) and stratified turbulence where the stratification strength is varied from weak (large Froude number $Fr\\gg1$) to strong ($Fr\\ll1$). The investigation is set in the context of a reduced model derived from the Boussinesq equations that efficiently retains anisotropic inertia-gravity waves with order-one frequencies and highlights a regime of wave-eddy interactions. Numerical simulations of the reduced model are performed where energy is injected by a stochastic forcing of vertical velocity, which forces wave modes only. The simulations reveal two regimes characterized by the presence of well-formed, persistent and thin turbulent layers of locally-weakened stratification at small Froude numbers, and by the absence of layers at large Froude numbers. Both regimes are characterized by a large-scale barotropic dipole enclosed by small-scale turbulence. When the Reynolds number is not too large a direct cascade of barotropic kinetic ener...

  4. A novel framework for fluid/structure interaction in rapid subject specific simulations of blood flow in coronary artery bifurcations

    Directory of Open Access Journals (Sweden)

    Blagojević Milan

    2014-01-01

    Full Text Available Background/Aim. Practical difficulties, particularly long model development time, have limited the types and applicability of computational fluid dynamics simulations in numerical modeling of blood flow in serial manner. In these simulations, the most revealing flow parameters are the endothelial shear stress distribution and oscillatory shear index. The aim of this study was analyze their role in the diagnosis of the occurrence and prognosis of plaque development in coronary artery bifurcations. Methods. We developed a novel modeling technique for rapid cardiovascular hemodynamic simulations taking into account interactions between fluid domain (blood and solid domain (artery wall. Two numerical models that represent the observed subdomains of an arbitrary patient-specific coronary artery bifurcation were created using multi-slice computed tomography (MSCT coronagraphy and ultrasound measurements of blood velocity. Coronary flow using an in-house finite element solver PAK-FS was solved. Results. Overall behavior of coronary artery bifurcation during one cardiac cycle is described by: velocity, pressure, endothelial shear stress, oscillatory shear index, stress in arterial wall and nodal displacements. The places where (a endothelial shear stress is less than 1.5, and (b oscillatory shear index is very small (close or equal to 0 are prone to plaque genesis. Conclusion. Finite element simulation of fluid-structure interaction was used to investigate patient-specific flow dynamics and wall mechanics at coronary artery bifurcations. Simulation model revealed that lateral walls of the main branch and lateral walls distal to the carina are exposed to low endothelial shear stress which is a predilection site for development of atherosclerosis. This conclusion is confirmed by the low values of oscillatory shear index in those places.

  5. Simple and rapid hydrogenation of p-nitrophenol with aqueous formic acid in catalytic flow reactors

    Directory of Open Access Journals (Sweden)

    Rahat Javaid

    2013-06-01

    Full Text Available The inner surface of a metallic tube (i.d. 0.5 mm was coated with a palladium (Pd-based thin metallic layer by flow electroless plating. Simultaneous plating of Pd and silver (Ag from their electroless-plating solution produced a mixed distributed bimetallic layer. Preferential acid leaching of Ag from the Pd–Ag layer produced a porous Pd surface. Hydrogenation of p-nitrophenol was examined in the presence of formic acid simply by passing the reaction solution through the catalytic tubular reactors. p-Aminophenol was the sole product of hydrogenation. No side reaction occurred. Reaction conversion with respect to p-nitrophenol was dependent on the catalyst layer type, the temperature, pH, amount of formic acid, and the residence time. A porous and oxidized Pd (PdO surface gave the best reaction conversion among the catalytic reactors examined. p-Nitrophenol was converted quantitatively to p-aminophenol within 15 s of residence time in the porous PdO reactor at 40 °C. Evolution of carbon dioxide (CO2 was observed during the reaction, although hydrogen (H2 was not found in the gas phase. Dehydrogenation of formic acid did not occur to any practical degree in the absence of p-nitrophenol. Consequently, the nitro group was reduced via hydrogen transfer from formic acid to p-nitrophenol and not by hydrogen generated by dehydrogenation of formic acid.

  6. Development of a Lateral Flow Immunoassay for the Rapid Diagnosis of Invasive Candidiasis

    Science.gov (United States)

    He, Zheng-Xin; Shi, Lan-Chun; Ran, Xiang-Yang; Li, Wei; Wang, Xian-Ling; Wang, Fu-Kun

    2016-01-01

    Early and accurate diagnosis of invasive candidiasis (IC) is very important. In this study, a lateral flow immunoassay (LFIA) was developed to detect antibody against Candida albicans enolase (Eno). Colloidal gold particle labeled mouse anti human IgG (1.0 mg/L) was used as the detector reagent. Recombinant enolase (rEno, 1.0 mg/L) and goat anti IgG (1.0 mg/L) were immobilized in test and control lines, respectively, of a nitrocellulose membrane, acting as the capture reagents. The LFIA was used to detect anti Eno in 38 sera from clinically proven IC patients, as well as in 50 healthy control subjects. Compared with an indirect ELISA designed as a reference test, the specificity and sensitivity of the LFIA were 98.2 and 84.8%, respectively. Excellent agreement between the results obtained by ELISA and the LFIA (κ = 0.851) was observed in this study. In addition, the agreement between the blood culture results and LFIA test is strong (κ = 0.658). The data presented in the study indicate that the LFIA test is a suitable tool for the serological surveillance of IC in the field or in poorly equipped laboratories. PMID:27679622

  7. Rapid identification of a narcotic plant Papaver bracteatum using flow cytometry.

    Science.gov (United States)

    Aragane, Masako; Watanabe, Daisuke; Nakajima, Jun'ichi; Yoshida, Masao; Yoshizawa, Masao; Abe, Tomohiro; Nishiyama, Rei; Suzuki, Jin; Moriyasu, Takako; Nakae, Dai; Sudo, Hiroshi; Sato, Hiroyuki; Hishida, Atuyuki; Kawahara, Nobuo; Makabe, So; Nakamura, Ikuo; Mii, Masahiro

    2014-10-01

    In May 2011, numerous poppy plants closely resembling Papaver bracteatum Lindl., a type of narcotic plant that is illegal in Japan, were distributed directly from several large flower shops or through online shopping throughout Japan, including the Tokyo Metropolitan area. In order to better identify the narcotic plants, the relative nuclear DNA content at the vegetative stage was measured by flow cytometric (FCM) analysis in 3 closely-related species of the genus Papaver section Oxytona, namely P. orientale, P. pseudo-orientale, and P. bracteatum, based on the difference between the chromosome numbers of these species. The results showed that the nuclear DNA content differed between these 3 species, and that most of the commercially distributed plants examined in this study could be identified as P. bracteatum. The remaining plants were P. pseudo-orientale, a non-narcotic plant. In addition, the FCM results for the identification of P. bracteatum completely agreed with the results obtained by the morphological analysis, the inter-genic spacer sequence of rpl16-rpl14 (PS-ID sequence) of chloroplast DNA, and the presence of thebaine. These results clearly indicate the usefulness of FCM analysis for the identification of P. bracteatum plants, including when they are in their vegetative stage.

  8. Establishment and Application of Early Warning System for Flood and Debris Flow Triggered by Rapid Erosion of Natural Barrier

    Science.gov (United States)

    Kaji, A.; Mizuno, H.; Yamakoshi, T.; Ishizuka, T.

    2012-04-01

    A large amount of mass of land from a mountain slides into a gorge and a river, depositing on the bed. The formation of such natural barrier provides a dam called "a natural dam", allowing water to accumulate in the upstream. People living in the downstream of basin are at risk of flood triggered by the dam break. Recently, many people have been at such risk emerged by earthquakes and heavy rainfall therefore they have been requesting to establish an early warning system for such flood risk. By analyzing the past case of the formations and the natural dam breaks in Japan, it was found that the surface flow on the natural dam eroded the deposition rapidly and the accumulated water and the deposition started to flow downstream in many cases. So that an alert should be issued by forecasting when the accumulated water in the upstream starts to flow on the deposition. In order to forecast the timing, we have to take into consideration of the difference between the water volume of flowing to the lake from the upstream basin and that of seeping into the deposition. Our final target is to develop a method for estimating the two previous quantities. In the first step, we report the result of analysis of the past cases in Japan. We focused on the two natural dams in the Yuhama village in Miyagi prefecture and in the Nagatono village in Nara prefecture. The natural dam in Yuhama village was formed by a deep-seated landslide triggered by the earthquake in 2008, and the natural dam in Nagatono was formed by a deep-seated landslide triggered by heavy rainfall in 2011. In the Yuhama case, the water level of the accumulated water had been rising until it reached to the top of the natural dam. In the Nagatono case, the water level had been rising during rainfall, however the water level had been dropping after the rainfall. The difference between the water volume of flowing in and that of flowing out from the natural dam caused the tendencies. We are going to analyze the soil

  9. Cerebral O2 metabolism and cerebral blood flow in humans during deep and rapid-eye-movement sleep

    DEFF Research Database (Denmark)

    Madsen, P L; Schmidt, J F; Wildschiødtz, Gordon

    1991-01-01

    It could be expected that the various stages of sleep were reflected in variation of the overall level of cerebral activity and thereby in the magnitude of cerebral metabolic rate of oxygen (CMRO2) and cerebral blood flow (CBF). The elusive nature of sleep imposes major methodological restrictions...... on examination of this question. We have now measured CBF and CMRO2 in young healthy volunteers using the Kety-Schmidt technique with 133Xe as the inert gas. Measurements were performed during wakefulness, deep sleep (stage 3/4), and rapid-eye-movement (REM) sleep as verified by standard polysomnography...... associated with light anesthesia. During REM sleep (dream sleep) CMRO2 was practically the same as in the awake state. Changes in CBF paralleled changes in CMRO2 during both deep and REM sleep....

  10. Lateral-flow colloidal gold-based immunoassay for the rapid detection of deoxynivalenol with two indicator ranges

    Energy Technology Data Exchange (ETDEWEB)

    Kolosova, Anna Yu. [Laboratory of Food Analysis, Faculty of Pharmaceutical Sciences, Ghent University, Harelbekestraat 72, 9000 Ghent (Belgium)], E-mail: anna_kolosova@hotmail.com; Sibanda, Liberty [TOXI-TEST NV, Industrielaan 9a, 9990 Maldegem (Belgium); Dumoulin, Frederic [Laboratory of Food Analysis, Faculty of Pharmaceutical Sciences, Ghent University, Harelbekestraat 72, 9000 Ghent (Belgium); Lewis, Janet; Duveiller, Etienne [International Maize and Wheat Improvement Center (CIMMYT), Apdo. Postal 6-641, 06600 Mexico, D.F. (Mexico); Van Peteghem, Carlos; Saeger, Sarah de [Laboratory of Food Analysis, Faculty of Pharmaceutical Sciences, Ghent University, Harelbekestraat 72, 9000 Ghent (Belgium)

    2008-06-02

    A lateral-flow immunoassay using a colloidal gold-labelled monoclonal antibody was developed for the rapid detection of deoxynivalenol (DON). Different parameters, such as the amount of immunoreagents, type of the materials, composition of the blocking solution and of the detector reagent mixture, were investigated to provide the optimum assay performance. The experimental results demonstrated that such a visual test had an indicator range rather than a cut-off value. Thus, tests for DON determination with two different indicator ranges of 250-500 and 1000-2000 {mu}g kg{sup -1} were designed. The method allowed detection of DON at low and high concentration levels, which could be useful for research and practical purposes. The assay applied to spiked wheat and pig feed samples demonstrated accurate and reproducible results. The applicability of the developed lateral-flow test was also confirmed under real field conditions. The test strips prepared in Belgium were sent to Mexico, where they were used for the screening of DON contamination in different bread wheat entries from Fusarium Head Blight inoculated plots. The results were compared with those obtained by ELISA and LC-MS/MS. A poor correlation between ELISA and LC-MS/MS was observed. Visual results of the dipstick tests were in a good agreement with the results of the LC-MS/MS method. Coupled with a simple and fast sample preparation, this qualitative one-step test based on the visual evaluation of results did not require any equipment. Results could be obtained within 10 min. The described assay format can be used as a simple, rapid, cost-effective and robust on-site screening tool for mycotoxin contamination in different agricultural commodities.

  11. Three-Color Flow Cytometry Detection of Intracellular Cytokines in Peripheral Blood Mononuclear Cells: Comparative Analysis of Phorbol Myristate Acetate-Ionomycin and Phytohemagglutinin Stimulation

    Science.gov (United States)

    Baran, Jarołsaw; Kowalczyk, Danuta; Ożóg, Mariola; Zembala, Marek

    2001-01-01

    The assessment of intracellular cytokines at the single-cell level by flow cytometry has recently become a potent tool in many areas of cell biology and in defining the role of cytokines in various human diseases. Three-color flow cytometry for detection of intracellular cytokines combined with simultaneous determination of lymphocytes (CD3+ and CD4+) or monocytes (CD33+ and CD14+) was used for comparison of phytohemagglutinin (PHA)-and phorbol myristate acetate (PMA)-ionomycin-induced production of intracellular cytokines in peripheral blood mononuclear cells (PBMCs) of healthy donors. We found that the number of PBMCs stained for tumor necrosis factor alpha and gamma interferon after 6 h of activation was higher when PMA-ionomycin was used for stimulation, while the frequencies of cells positive for interleukin 4 (IL-4) were similar for both stimulators. However, PMA-ionomycin stimulation caused prominent alterations of cell morphology and membrane expression of CD4 and CD14. In contrast, PHA did not cause downregulation of surface markers and resulted in less pronounced alterations in both forward and side scatter signals during flow cytometry analysis. Moreover, during 48 h of culture PHA stimulated tumor necrosis factor beta and IL-10 production, which was not observed when PMA-ionomycin was used. We conclude that the use of PHA for cell activation may limit in vitro artifacts and allow more precise analysis of intracellular cytokine production in various disease states. PMID:11238213

  12. Objective rapid delineation of areas at risk from block-and-ash pyroclastic flows and surges

    Science.gov (United States)

    Widiwijayanti, C.; Voight, B.; Hidayat, D.; Schilling, S. P.

    2009-08-01

    Assessments of pyroclastic flow (PF) hazards are commonly based on mapping of PF and surge deposits and estimations of inundation limits, and/or computer models of varying degrees of sophistication. In volcanic crises a PF hazard map may be sorely needed, but limited time, exposures, or safety aspects may preclude fieldwork, and insufficient time or baseline data may be available for reliable dynamic simulations. We have developed a statistically constrained simulation model for block-and-ash type PFs to estimate potential areas of inundation by adapting methodology from Iverson et al. (Geol Soc America Bull 110:972-984, 1998) for lahars. The predictive equations for block-and-ash PFs are calibrated with data from several volcanoes and given by A = (0.05 to 0.1) V 2/3, B = (35 to 40) V 2/3, where A is cross-sectional area of inundation, B is planimetric area and V is deposit volume. The proportionality coefficients were obtained from regression analyses and comparison of simulations to mapped deposits. The method embeds the predictive equations in a GIS program coupled with DEM topography, using the LAHARZ program of Schilling (1998). Although the method is objective and reproducible, any PF hazard zone so computed should be considered as an approximate guide only, due to uncertainties on the coefficients applicable to individual PFs, the authenticity of DEM details, and the volume of future collapses. The statistical uncertainty of the predictive equations, which imply a factor of two or more in predicting A or B for a specified V, is superposed on the uncertainty of forecasting V for the next PF to descend a particular valley. Multiple inundation zones, produced by simulations using a selected range of volumes, partly accommodate these uncertainties. The resulting maps show graphically that PF inundation potentials are highest nearest volcano sources and along valley thalwegs, and diminish with distance from source and lateral distance from thalweg. The model

  13. Objective rapid delineation of areas at risk from block-and-ash pyroclastic flows and surges

    Science.gov (United States)

    Widiwijayanti, C.; Voight, B.; Hidayat, D.; Schilling, S.P.

    2009-01-01

    Assessments of pyroclastic flow (PF) hazards are commonly based on mapping of PF and surge deposits and estimations of inundation limits, and/or computer models of varying degrees of sophistication. In volcanic crises a PF hazard map may be sorely needed, but limited time, exposures, or safety aspects may preclude fieldwork, and insufficient time or baseline data may be available for reliable dynamic simulations. We have developed a statistically constrained simulation model for block-and-ash type PFs to estimate potential areas of inundation by adapting methodology from Iverson et al. (Geol Soc America Bull 110:972-984, (1998) for lahars. The predictive equations for block-and-ash PFs are calibrated with data from several volcanoes and given by A = (0.05 to 0.1) V2/3, B = (35 to 40) V2/3, where A is cross-sectional area of inundation, B is planimetric area and V is deposit volume. The proportionality coefficients were obtained from regression analyses and comparison of simulations to mapped deposits. The method embeds the predictive equations in a GIS program coupled with DEM topography, using the LAHARZ program of Schilling (1998). Although the method is objective and reproducible, any PF hazard zone so computed should be considered as an approximate guide only, due to uncertainties on the coefficients applicable to individual PFs, the authenticity of DEM details, and the volume of future collapses. The statistical uncertainty of the predictive equations, which imply a factor of two or more in predicting A or B for a specified V, is superposed on the uncertainty of forecasting V for the next PF to descend a particular valley. Multiple inundation zones, produced by simulations using a selected range of volumes, partly accommodate these uncertainties. The resulting maps show graphically that PF inundation potentials are highest nearest volcano sources and along valley thalwegs, and diminish with distance from source and lateral distance from thalweg. The model does

  14. A rapid lateral flow immunoassay for the detection of tyrosine phosphatase-like protein IA-2 autoantibodies in human serum.

    Directory of Open Access Journals (Sweden)

    Ingrid Kikkas

    Full Text Available Type 1 diabetes (T1D results from the destruction of pancreatic insulin-producing beta cells and is strongly associated with the presence of islet autoantibodies. Autoantibodies to tyrosine phosphatase-like protein IA-2 (IA-2As are considered to be highly predictive markers of T1D. We developed a novel lateral flow immunoassay (LFIA based on a bridging format for the rapid detection of IA-2As in human serum samples. In this assay, one site of the IA-2As is bound to HA-tagged-IA-2, which is subsequently captured on the anti-HA-Tag antibody-coated test line on the strip. The other site of the IA-2As is bound to biotinylated IA-2, allowing the complex to be visualized using colloidal gold nanoparticle-conjugated streptavidin. For this study, 35 serum samples from T1D patients and 44 control sera from non-diabetic individuals were analyzed with our novel assay and the results were correlated with two IA-2A ELISAs. Among the 35 serum samples from T1D patients, the IA-2A LFIA, the in-house IA-2A ELISA and the commercial IA-2A ELISA identified as positive 21, 29 and 30 IA-2A-positive sera, respectively. The major advantages of the IA-2A LFIA are its rapidity and simplicity.

  15. Measurement of the rapidity-even dipolar flow in Pb-Pb collisions with the ATLAS detector

    CERN Document Server

    Jia, Jiangyong

    2012-01-01

    The rapidity-even dipolar flow v1 associated with dipole asymmetry in the initial geometry is measured over a broad range in transverse momentum 0.5 GeVrapidity-even v1 and global momentum conservation. The magnitude of the extracted momentum conservation component suggests that the system conserving momentum involves only a subset of the event (spanning about 3 units in \\eta in central collisions). The extracted v1 is observed to cross zero at pT~1.0 GeV, reaches a maximum at 4-5 GeV with a value comparable to that for v...

  16. Flow Injection Analysis with Electrochemical Detection for Rapid Identification of Platinum-Based Cytostatics and Platinum Chlorides in Water

    Directory of Open Access Journals (Sweden)

    Marketa Kominkova

    2014-02-01

    Full Text Available Platinum-based cytostatics, such as cisplatin, carboplatin or oxaliplatin are widely used agents in the treatment of various types of tumors. Large amounts of these drugs are excreted through the urine of patients into wastewaters in unmetabolised forms. This phenomenon leads to increased amounts of platinum ions in the water environment. The impacts of these pollutants on the water ecosystem are not sufficiently investigated as well as their content in water sources. In order to facilitate the detection of various types of platinum, we have developed a new, rapid, screening flow injection analysis method with electrochemical detection (FIA-ED. Our method, based on monitoring of the changes in electrochemical behavior of analytes, maintained by various pH buffers (Britton-Robinson and phosphate buffer and potential changes (1,000, 1,100 and 1,200 mV offers rapid and cheap selective determination of platinum-based cytostatics and platinum chlorides, which can also be present as contaminants in water environments.

  17. Flow injection analysis with electrochemical detection for rapid identification of platinum-based cytostatics and platinum chlorides in water.

    Science.gov (United States)

    Kominkova, Marketa; Heger, Zbynek; Zitka, Ondrej; Kynicky, Jindrich; Pohanka, Miroslav; Beklova, Miroslava; Adam, Vojtech; Kizek, Rene

    2014-02-04

    Platinum-based cytostatics, such as cisplatin, carboplatin or oxaliplatin are widely used agents in the treatment of various types of tumors. Large amounts of these drugs are excreted through the urine of patients into wastewaters in unmetabolised forms. This phenomenon leads to increased amounts of platinum ions in the water environment. The impacts of these pollutants on the water ecosystem are not sufficiently investigated as well as their content in water sources. In order to facilitate the detection of various types of platinum, we have developed a new, rapid, screening flow injection analysis method with electrochemical detection (FIA-ED). Our method, based on monitoring of the changes in electrochemical behavior of analytes, maintained by various pH buffers (Britton-Robinson and phosphate buffer) and potential changes (1,000, 1,100 and 1,200 mV) offers rapid and cheap selective determination of platinum-based cytostatics and platinum chlorides, which can also be present as contaminants in water environments.

  18. Rapid, Precise, and Accurate Counts of Symbiodinium Cells Using the Guava Flow Cytometer, and a Comparison to Other Methods.

    Science.gov (United States)

    Krediet, Cory J; DeNofrio, Jan C; Caruso, Carlo; Burriesci, Matthew S; Cella, Kristen; Pringle, John R

    2015-01-01

    In studies of both the establishment and breakdown of cnidarian-dinoflagellate symbiosis, it is often necessary to determine the number of Symbiodinium cells relative to the quantity of host tissue. Ideally, the methods used should be rapid, precise, and accurate. In this study, we systematically evaluated methods for sample preparation and storage and the counting of algal cells using the hemocytometer, a custom image-analysis program for automated counting of the fluorescent algal cells, the Coulter Counter, or the Millipore Guava flow-cytometer. We found that although other methods may have value in particular applications, for most purposes, the Guava flow cytometer provided by far the best combination of precision, accuracy, and efficient use of investigator time (due to the instrument's automated sample handling), while also allowing counts of algal numbers over a wide range and in small volumes of tissue homogenate. We also found that either of two assays of total homogenate protein provided a precise and seemingly accurate basis for normalization of algal counts to the total amount of holobiont tissue.

  19. Rapid, Precise, and Accurate Counts of Symbiodinium Cells Using the Guava Flow Cytometer, and a Comparison to Other Methods.

    Directory of Open Access Journals (Sweden)

    Cory J Krediet

    Full Text Available In studies of both the establishment and breakdown of cnidarian-dinoflagellate symbiosis, it is often necessary to determine the number of Symbiodinium cells relative to the quantity of host tissue. Ideally, the methods used should be rapid, precise, and accurate. In this study, we systematically evaluated methods for sample preparation and storage and the counting of algal cells using the hemocytometer, a custom image-analysis program for automated counting of the fluorescent algal cells, the Coulter Counter, or the Millipore Guava flow-cytometer. We found that although other methods may have value in particular applications, for most purposes, the Guava flow cytometer provided by far the best combination of precision, accuracy, and efficient use of investigator time (due to the instrument's automated sample handling, while also allowing counts of algal numbers over a wide range and in small volumes of tissue homogenate. We also found that either of two assays of total homogenate protein provided a precise and seemingly accurate basis for normalization of algal counts to the total amount of holobiont tissue.

  20. The effect of isometric exercise of the hand on the synovial blood flow in patients with rheumatoid arthritis measured by color Doppler ultrasound.

    Science.gov (United States)

    Ellegaard, Karen; Torp-Pedersen, Søren; Lund, Hans; Pedersen, Kirsten; Henriksen, Marius; Danneskiold-Samsøe, Bente; Bliddal, Henning

    2013-01-01

    In 90% of patients with rheumatoid arthritis (RA), the joints of the hand are affected. Studies of grip strength training have not indicated a negative effect on disease activity after training. Introduction of ultrasound Doppler (USD) to measure increased blood flow induced by inflammation has made it possible to investigate the direct effect on blood supply in the synovium after training. In this case-control study, 24 patients with RA with USD activity in the wrist joint participated. The USD activity was measured by the color fraction (CF) (CF = colored pixels/total number of pixels in ROI). Twenty-four patients were assigned to an 8-week grip strength training program. At baseline and after 8 weeks of training, an USD examination of the wrist joint was performed. In the training group, we measured grip strength and pain in the wrist joint. Six patients withdrew from the training because of pain or change in medication. Eighteen patients served as control group. There was a modest, not significant, decrease in the CF in response to training (1.86%; P = 0.08). Grip strength increased 8.8% after training (P = 0.055). Pain in motion deceased after training (P = 0.04). No difference in the CF was seen between the training and control groups, neither at baseline nor at follow-up (P = 0.82 and P = 0.48). Patients withdrawing from training had a significantly higher CF than the other patients (P > 0.001). The results in this study might indicate that the flow in the synovium assessed by USD is not affected by grip strength training.

  1. Effects of gadolinium chloride on basal flow and compression-induced rapid hyperemia in the rabbit masseter muscle.

    Science.gov (United States)

    Turturici, M; Roatta, S

    2014-06-01

    Aim of the present study is to investigate the role of mechano-sensitive channels on basal muscle blood flow and on the compression-induced rapid hyperaemia. To this aim, the mechano-sensitive channel blocker Gadolinium (Gd(3+)) is employed, which already proved to reduce the myogenic response in isolated vessels. Muscle blood flow (MaBF) was recorded from the masseteric artery in 8 urethane-anesthetized rabbits. Rapid hyperemic responses were evoked by 1-s lasting compressions of the masseter muscle (MC) delivered before and after close arterial infusion of Gd(3+) in the masseteric artery. Three infusions were performed at 1-h interval, producing estimated plasma concentration (EPC) of 0.045, 0.45 and 4.5 mM, in the masseteric artery. The amplitude of the hyperaemic response to MC, equal to 195±77% of basal flow in control condition, was reduced by 9.5±19.4% (p=0.18) and 45±28% (p<0.01) while basal MaBf increased by 10±3% (p=0.90) and by 68±30% (p<0.01) at EPC of 0.045 and 0.45 mM, respectively. At EPC of 4.5 mM a strong reduction in both MaBF (by 54±13%, p<0.01) and MC response (75±12%, p<0.01) was instead observed. These effects did not depend on time from infusion. At all doses employed Gd(3+) never affected arterial blood pressure, heart rate and contralateral MaBF. While the effects observed at the highest EPC likely result from blood vessel occlusion due to Gd(3+) precipitation, the effects observed at lower concentrations demonstrate that Gd(3+) affects musculo-vascular function by decreasing both resting vascular tone and responsiveness to mechanical stimuli. The results are compatible with a Gd(3+)-induced blockade of vascular mechano-sensitive channels.

  2. Ocean Color

    Data.gov (United States)

    National Aeronautics and Space Administration — Satellite-derived Ocean Color Data sets from historical and currently operational NASA and International Satellite missions including the NASA Coastal Zone Color...

  3. Entropy, color, and color rendering.

    Science.gov (United States)

    Price, Luke L A

    2012-12-01

    The Shannon entropy [Bell Syst. Tech J.27, 379 (1948)] of spectral distributions is applied to the problem of color rendering. With this novel approach, calculations for visual white entropy, spectral entropy, and color rendering are proposed, indices that are unreliant on the subjectivity inherent in reference spectra and color samples. The indices are tested against real lamp spectra, showing a simple and robust system for color rendering assessment. The discussion considers potential roles for white entropy in several areas of color theory and psychophysics and nonextensive entropy generalizations of the entropy indices in mathematical color spaces.

  4. Color invariance

    NARCIS (Netherlands)

    Geusebroek, J.M.; van den Boomgaard, R.; Smeulders, A.W.M.; Geerts, H.

    2001-01-01

    This paper presents the measurement of colored object reflectance, under different, general assumptions regarding the imaging conditions. We exploit the Gaussian scale-space paradigm for color images to define a framework for the robust measurement of object reflectance from color images. Object ref

  5. Color Algebras

    Science.gov (United States)

    Mulligan, Jeffrey B.

    2017-01-01

    A color algebra refers to a system for computing sums and products of colors, analogous to additive and subtractive color mixtures. We would like it to match the well-defined algebra of spectral functions describing lights and surface reflectances, but an exact correspondence is impossible after the spectra have been projected to a three-dimensional color space, because of metamerism physically different spectra can produce the same color sensation. Metameric spectra are interchangeable for the purposes of addition, but not multiplication, so any color algebra is necessarily an approximation to physical reality. Nevertheless, because the majority of naturally-occurring spectra are well-behaved (e.g., continuous and slowly-varying), color algebras can be formulated that are largely accurate and agree well with human intuition. Here we explore the family of algebras that result from associating each color with a member of a three-dimensional manifold of spectra. This association can be used to construct a color product, defined as the color of the spectrum of the wavelength-wise product of the spectra associated with the two input colors. The choice of the spectral manifold determines the behavior of the resulting system, and certain special subspaces allow computational efficiencies. The resulting systems can be used to improve computer graphic rendering techniques, and to model various perceptual phenomena such as color constancy.

  6. A novel high-throughput multi-parameter flow cytometry based method for monitoring and rapid characterization of microbiome dynamics in anaerobic systems.

    Science.gov (United States)

    Dhoble, Abhishek S; Bekal, Sadia; Dolatowski, William; Yanz, Connor; Lambert, Kris N; Bhalerao, Kaustubh D

    2016-11-01

    A novel multidimensional flow cytometry based method has been demonstrated to monitor and rapidly characterize the dynamics of the complex anaerobic microbiome associated with perturbations in external environmental factors. While community fingerprinting provides an estimate of the meta genomic structure, flow cytometry provides a fingerprint of the community morphology including its autofluorescence spectrum in a high-throughput manner. Using anaerobic microbial consortia perturbed with the controlled addition of various carbon sources, it is possible to quantitatively discriminate between divergent microbiome analogous to community fingerprinting techniques using automated ribosomal intergenic spacer analysis (ARISA). The utility of flow cytometry based method has also been demonstrated in a fully functional industry scale anaerobic digester to distinguish between microbiome composition caused by varying hydraulic retention time (HRT). This approach exploits the rich multidimensional information from flow cytometry for rapid characterization of the dynamics of microbial communities.

  7. Rapid detection of abrin in foods with an up-converting phosphor technology-based lateral flow assay

    Science.gov (United States)

    Liu, Xiao; Zhao, Yong; Sun, Chongyun; Wang, Xiaochen; Wang, Xinrui; Zhang, Pingping; Qiu, Jingfu; Yang, Ruifu; Zhou, Lei

    2016-01-01

    Abrin is a natural plant toxin found in the seeds of Abrus precatorius. It may be used for food poisoning or bioterrorism, seriously endangering public health. In this study, a reliable method for the rapid detection of abrin in foods was developed, based on an up-converting phosphor technology-based lateral flow assay (abrin-UPT-LFA). Nine high-affinity monoclonal antibodies (mAbs) against abrin were prepared, and the optimum mAbs (mAb-6F4 and mAb-10E11) were selected for use in the assay in double-antibody-sandwich mode. The assay was confirmed to be specific for abrin, with a detection sensitivity of 0.1 ng mL−1 for standard abrin solutions. Good linearity was observed for abrin quantitation from 0.1 to 1000 ng mL−1 (r = 0.9983). During the analysis of various abrin-spiked food samples, the assay showed strong sample tolerance and a satisfactory limit of detection for abrin (0.5–10 ng g−1 for solid and powdered samples; 0.30–0.43 ng mL−1 for liquid samples). The analysis of suspected food samples, from sample treatment to result feed-back, could be completed by non-professionals within 20 min. Therefore, the abrin-UPT-LFA is a rapid, sensitive, and reliable method for the on-site detection of abrin in foods. PMID:27703269

  8. Application of a SERS-based lateral flow immunoassay strip for the rapid and sensitive detection of staphylococcal enterotoxin B

    Science.gov (United States)

    Hwang, Joonki; Lee, Sangyeop; Choo, Jaebum

    2016-06-01

    A novel surface-enhanced Raman scattering (SERS)-based lateral flow immunoassay (LFA) biosensor was developed to resolve problems associated with conventional LFA strips (e.g., limits in quantitative analysis and low sensitivity). In our SERS-based biosensor, Raman reporter-labeled hollow gold nanospheres (HGNs) were used as SERS detection probes instead of gold nanoparticles. With the proposed SERS-based LFA strip, the presence of a target antigen can be identified through a colour change in the test zone. Furthermore, highly sensitive quantitative evaluation is possible by measuring SERS signals from the test zone. To verify the feasibility of the SERS-based LFA strip platform, an immunoassay of staphylococcal enterotoxin B (SEB) was performed as a model reaction. The limit of detection (LOD) for SEB, as determined with the SERS-based LFA strip, was estimated to be 0.001 ng mL-1. This value is approximately three orders of magnitude more sensitive than that achieved with the corresponding ELISA-based method. The proposed SERS-based LFA strip sensor shows significant potential for the rapid and sensitive detection of target markers in a simplified manner.A novel surface-enhanced Raman scattering (SERS)-based lateral flow immunoassay (LFA) biosensor was developed to resolve problems associated with conventional LFA strips (e.g., limits in quantitative analysis and low sensitivity). In our SERS-based biosensor, Raman reporter-labeled hollow gold nanospheres (HGNs) were used as SERS detection probes instead of gold nanoparticles. With the proposed SERS-based LFA strip, the presence of a target antigen can be identified through a colour change in the test zone. Furthermore, highly sensitive quantitative evaluation is possible by measuring SERS signals from the test zone. To verify the feasibility of the SERS-based LFA strip platform, an immunoassay of staphylococcal enterotoxin B (SEB) was performed as a model reaction. The limit of detection (LOD) for SEB, as

  9. Sensitivity and Specificity of a New Vertical Flow Rapid Diagnostic Test for the Serodiagnosis of Human Leptospirosis.

    Directory of Open Access Journals (Sweden)

    Cyrille Goarant

    2013-06-01

    Full Text Available Background : Leptospirosis is a growing public health concern in many tropical and subtropical countries. However, its diagnosis is difficult because of non-specific symptoms and concurrent other endemic febrile diseases. In many regions, the laboratory diagnosis is not available due to a lack of preparedness and simple diagnostic assay or difficult access to reference laboratories. Yet, an early antibiotic treatment is decisive to the outcome. The need for Rapid Diagnostic Tests (RDTs for bedside diagnosis of leptospirosis has been recognized. We developed a vertical flow immunochromatography strip RDT detecting anti-Leptospira human IgM and evaluated it in patients from New Caledonia, France, and French West Indies. Methodology/Principal Findings : Whole killed Leptospira fainei cells were used as antigen for the test line and purified human IgM as the control line. The mobile phase was made of gold particles conjugated with goat anti-human IgM. Standards for Reporting of Diagnostic Accuracy criteria were used to assess the performance of this RDT. The Microscopic Agglutination Test (MAT was used as the gold standard with a cut-off titer of ≥400. The sensitivity was 89.8% and the specificity 93.7%. Positive and negative Likelihood Ratios of 14.18 and 0.108 respectively, and a Diagnostic Odds Ratio of 130.737 confirmed its usefulness. This RDT had satisfactory reproducibility, repeatability, thermal tolerance and shelf-life. The comparison with MAT evidenced the earliness of the RDT to detect seroconversion. When compared with other RDT, the Vertical Flow RDT developed displayed good diagnostic performances.This RDT might be used as a point of care diagnostic tool in limited resources countries. An evaluation in field conditions and in other epidemiological contexts should be considered to assess its validity over a wider range of serogroups or when facing different endemic pathogens. It might prove useful in endemic contexts or outbreak

  10. Color Categories and Color Appearance

    Science.gov (United States)

    Webster, Michael A.; Kay, Paul

    2012-01-01

    We examined categorical effects in color appearance in two tasks, which in part differed in the extent to which color naming was explicitly required for the response. In one, we measured the effects of color differences on perceptual grouping for hues that spanned the blue-green boundary, to test whether chromatic differences across the boundary…

  11. Color Categories and Color Appearance

    Science.gov (United States)

    Webster, Michael A.; Kay, Paul

    2012-01-01

    We examined categorical effects in color appearance in two tasks, which in part differed in the extent to which color naming was explicitly required for the response. In one, we measured the effects of color differences on perceptual grouping for hues that spanned the blue-green boundary, to test whether chromatic differences across the boundary…

  12. Endothelial function and sleep: associations of flow-mediated dilation with perceived sleep quality and rapid eye movement (REM) sleep.

    Science.gov (United States)

    Cooper, Denise C; Ziegler, Michael G; Milic, Milos S; Ancoli-Israel, Sonia; Mills, Paul J; Loredo, José S; Von Känel, Roland; Dimsdale, Joel E

    2014-02-01

    Endothelial function typically precedes clinical manifestations of cardiovascular disease and provides a potential mechanism for the associations observed between cardiovascular disease and sleep quality. This study examined how subjective and objective indicators of sleep quality relate to endothelial function, as measured by brachial artery flow-mediated dilation (FMD). In a clinical research centre, 100 non-shift working adults (mean age: 36 years) completed FMD testing and the Pittsburgh Sleep Quality Index, along with a polysomnography assessment to obtain the following measures: slow wave sleep, percentage rapid eye movement (REM) sleep, REM sleep latency, total arousal index, total sleep time, wake after sleep onset, sleep efficiency and apnea-hypopnea index. Bivariate correlations and follow-up multiple regressions examined how FMD related to subjective (i.e., Pittsburgh Sleep Quality Index scores) and objective (i.e., polysomnography-derived) indicators of sleep quality. After FMD showed bivariate correlations with Pittsburgh Sleep Quality Index scores, percentage REM sleep and REM latency, further examination with separate regression models indicated that these associations remained significant after adjustments for sex, age, race, hypertension, body mass index, apnea-hypopnea index, smoking and income (Ps Quality Index increased (indicating decreased subjective sleep quality) and percentage REM sleep decreased, while REM sleep latency increased (Ps quality and adverse changes in REM sleep were associated with diminished vasodilation, which could link sleep disturbances to cardiovascular disease.

  13. Color Analysis

    Science.gov (United States)

    Wrolstad, Ronald E.; Smith, Daniel E.

    Color, flavor, and texture are the three principal quality attributes that determine food acceptance, and color has a far greater influence on our judgment than most of us appreciate. We use color to determine if a banana is at our preferred ripeness level, and a discolored meat product can warn us that the product may be spoiled. The marketing departments of our food corporations know that, for their customers, the color must be "right." The University of California Davis scorecard for wine quality designates four points out of 20, or 20% of the total score, for color and appearance (1). Food scientists who establish quality control specifications for their product are very aware of the importance of color and appearance. While subjective visual assessment and use of visual color standards are still used in the food industry, instrumental color measurements are extensively employed. Objective measurement of color is desirable for both research and industrial applications, and the ruggedness, stability, and ease of use of today's color measurement instruments have resulted in their widespread adoption.

  14. 彩色多普勒血流显像对原发性胆囊癌的诊断意义%Significance of color Dopoler flow imaging in the diagnosis of primary gallbladder cancer

    Institute of Scientific and Technical Information of China (English)

    张学兰; 许汉生; 王金穗; 陶炜; 李桂花

    2000-01-01

    Objective To obeserve the abnormal high velocity arterial blood flow signal within masses of the gallbladder and gallbladder wall.in order to investigae the fignificances of the color Doppler flow imaging in diagnosing the primary gallbladder cancer.Methods Data of the gallbladder artery of 22 cases with primary gallbladder adenocarcinoma and 30 normal persons were measured by color Doppler flow imaging.The measured indexes included the maximum blood flow velocity(Vmax),minimum blood flow velocity(Vmin),time-average blood flow velocity(Vmean),pulsatility index(PI),resistance index(RI),and ratio of the maximum tO minimum blood flow velocity(A/B).Results Blood flow signals were measured in 17 0f 22 cases with primary gallbladder cancer.Their Vmax,Vmin and vnmwere significantly higher than those in normal control group(P0.1).16例以实质性肿物为表现的原发性胆囊癌的肿块内测到高阻中速血流频谱.结论 胆囊动脉的高阻高、中速血流信号,是原发性胆囊癌具有诊断价值的特征.肿瘤内的血流信号是鉴别胆囊癌与由结石和胆泥所形成的伪瘤样回声的可靠征象.

  15. Processing of Color Words Activates Color Representations

    Science.gov (United States)

    Richter, Tobias; Zwaan, Rolf A.

    2009-01-01

    Two experiments were conducted to investigate whether color representations are routinely activated when color words are processed. Congruency effects of colors and color words were observed in both directions. Lexical decisions on color words were faster when preceding colors matched the color named by the word. Color-discrimination responses…

  16. The studay on the blood flow in Kidney with Chronic Renal Failure Using Color Histogram%彩色直方图对慢性肾功能衰竭患者肾脏血流的分析研究

    Institute of Scientific and Technical Information of China (English)

    杨爽; 刘瑜; 祝艳秋

    2014-01-01

    目的:应用彩色直方图对正常肾脏和慢性肾功能衰竭患者肾脏的血流进行定量分析。方法慢性肾功能衰竭患者90例,应用彩色直方图软件测得肾脏内彩色血流占肾脏面积的百分比(Black and white color ratio,BCR),并与60例健康对照组对比。结果健康对照组与病例组之间BCR的均值在统计学上有显著意义(P<0.05)。结论应用彩色直方图可以得出慢性肾功能衰竭患者肾脏血流量化的客观指标,从而为临床进一步提高对慢性肾功能衰竭诊断提供参考价值。%Objective Color histogram for normal kidney and renal failure in patients with chronic renal blood flow for quantitative analysis.Methods 90 patients with chronic renal failure patients using color histogram software measured the percentage of color flow within the kidney kidney area (Black and white color ratio, BCR),and with 60 cases of healthy control group comparison.Results The mean BCR between healthy control group and patients groups was significant statistically (P<0.05).Conclusion Color histogram can be drawn with chronic renal failure in patients with renal blood flow quantification of objective indicators, so as to further improve clinical chronic renal failure diagnosis reference value.

  17. Optofluidic biosensors: miniaturized multi-color flow cytometer and fluorescence-activated cell sorter (microFACS)

    Science.gov (United States)

    Cho, Sung Hwan; Chen, Chun-Hao; Lo, Yu-Hwa

    2011-10-01

    We report a portable, low-cost, and high-performance microfluidics based fluorescence-activated cell sorter (microFACS) system to isolate E.coli. cells in combination with a modified specific fluorescence labeling method called tyramide signal amplification-fluorescence in situ hybridization (TSA-FISH). One of the primary challenges in studying bacterial communities that elude cell culturing is to isolate of low abundance bacteria cell from heterogeneous microbial samples. The proposed TSA-FISH protocol is flow cytometry compatible and yields about 10-fold enhancement in fluorescence labeling intensity over widely used standard FISH staining methods. Teflon AF coated optofluidic waveguide and space-time coding with a matched filter algorithm enhance its detection sensitivity. The microFACS is also able to enrich TSA-FISH labeled E.coli. cells by a factor of 223 with an integrated piezoelectric actuator and realtime control electronics system. The microFACS in conjunction with the modified TSA-FISH technologies demonstrates a highly effective and low cost solution potentially for the genomic complexity of complex bacterial communities.

  18. Colored operads

    CERN Document Server

    Yau, Donald

    2016-01-01

    The subject of this book is the theory of operads and colored operads, sometimes called symmetric multicategories. A (colored) operad is an abstract object which encodes operations with multiple inputs and one output and relations between such operations. The theory originated in the early 1970s in homotopy theory and quickly became very important in algebraic topology, algebra, algebraic geometry, and even theoretical physics (string theory). Topics covered include basic graph theory, basic category theory, colored operads, and algebras over colored operads. Free colored operads are discussed in complete detail and in full generality. The intended audience of this book includes students and researchers in mathematics and other sciences where operads and colored operads are used. The prerequisite for this book is minimal. Every major concept is thoroughly motivated. There are many graphical illustrations and about 150 exercises. This book can be used in a graduate course and for independent study.

  19. Fuzzy boundaries: color and gene flow patterns among parapatric lineages of the western shovel-nosed snake and taxonomic implication

    Science.gov (United States)

    Wood, Dustin A.; Fisher, Robert N.; Vandergast, Amy G.

    2014-01-01

    Accurate delineation of lineage diversity is increasingly important, as species distributions are becoming more reduced and threatened. During the last century, the subspecies category was often used to denote phenotypic variation within a species range and to provide a framework for understanding lineage differentiation, often considered incipient speciation. While this category has largely fallen into disuse, previously recognized subspecies often serve as important units for conservation policy and management when other information is lacking. In this study, we evaluated phenotypic subspecies hypotheses within shovel-nosed snakes on the basis of genetic data and considered how evolutionary processes such as gene flow influenced possible incongruence between phenotypic and genetic patterns. We used both traditional phylogenetic and Bayesian clustering analyses to infer range-wide genetic structure and spatially explicit analyses to detect possible boundary locations of lineage contact. Multilocus analyses supported three historically isolated groups with low to moderate levels of contemporary gene exchange. Genetic data did not support phenotypic subspecies as exclusive groups, and we detected patterns of discordance in areas where three subspecies are presumed to be in contact. Based on genetic and phenotypic evidence, we suggested that species-level diversity is underestimated in this group and we proposed that two species be recognized, Chionactis occipitalis and C. annulata. In addition, we recommend retention of two subspecific designations within C. annulata (C. a. annulata and C. a. klauberi) that reflect regional shifts in both genetic and phenotypic variation within the species. Our results highlight the difficultly in validating taxonomic boundaries within lineages that are evolving under a time-dependent, continuous process.

  20. COLOR IMAGES

    Directory of Open Access Journals (Sweden)

    Dominique Lafon

    2011-05-01

    Full Text Available The goal of this article is to present specific capabilities and limitations of the use of color digital images in a characterization process. The whole process is investigated, from the acquisition of digital color images to the analysis of the information relevant to various applications in the field of material characterization. A digital color image can be considered as a matrix of pixels with values expressed in a vector-space (commonly 3 dimensional space whose specificity, compared to grey-scale images, is to ensure a coding and a representation of the output image (visualisation printing that fits the human visual reality. In a characterization process, it is interesting to regard color image attnbutes as a set of visual aspect measurements on a material surface. Color measurement systems (spectrocolorimeters, colorimeters and radiometers and cameras use the same type of light detectors: most of them use Charge Coupled Devices sensors. The difference between the two types of color data acquisition systems is that color measurement systems provide a global information of the observed surface (average aspect of the surface: the color texture is not taken into account. Thus, it seems interesting to use imaging systems as measuring instruments for the quantitative characterization of the color texture.

  1. Stepwise discriminant function analysis for rapid identification of acute promyelocytic leukemia from acute myeloid leukemia with multiparameter flow cytometry.

    Science.gov (United States)

    Chen, Zhanguo; Li, Yan; Tong, Yongqing; Gao, Qingping; Mao, Xiaolu; Zhang, Wenjing; Xia, Zunen; Fu, Chaohong

    2016-03-01

    Diagnosis of acute promyelocytic leukemia (APL) has been accelerated by multiparameter flow cytometry (MFC). However, diagnostic interpretation of MFC readouts for APL depends on individual experience and knowledge, which inevitably increases the risk of arbitrariness. We appraised the feasibility of using stepwise discriminant function analysis (SDFA) based on MFC to optimize the minimal variables needed to distinguish APL from other acute myeloid leukemia (AML) without complicated data interpretation. Samples from 327 patients with APL (n = 51) and non-APL AML (n = 276) were randomly allocated into training (243 AML) and test sets (84 AML) for SDFA. The discriminant functions from SDFA were examined by correct classification, and the final variables were validated by differential expression. Finally, additional 20 samples from patients with atypical APL and AML confusable with APL were also identified by SDFA method and morphological analysis. The weighed discriminant function reveals seven differentially expressed variables (CD2/CD9/CD11b/CD13/CD34/HLA-DR/CD117), which predict a molecular result for APL characterization with an accuracy that approaches 99% (99.6 and 98.8% for AML samples in training and test sets, respectively). Furthermore, the SDFA outperformed either single variable analysis or the more limited 3-component analysis (CD34/CD117/HLA-DR) via separate SDFA, and was also superior to morphological analysis in terms of diagnostic efficacy. The established SDFA based on MFC with seven variables can precisely and rapidly differentiate APL and non-APL AML, which may contribute to the urgent initiation of all-trans-retinoic acid-based APL therapy.

  2. Validation of rapid velocity encoded cine imaging of a dynamically complex flow field using turbo block regional interpolation scheme for k space.

    Science.gov (United States)

    Kortright, E; Doyle, M; Anayiotos, A S; Walsh, E G; Fuisz, A R; Pohost, G M

    2001-02-01

    Block regional interpolation scheme for k space (BRISK) is a sparse sampling approach to allow rapid magnetic resonance imaging of dynamic events. Rapid velocity encoded cine (VEC) imaging with Turbo BRISK is potentially an important clinical diagnostic technique for cardiovascular diseases. Previously we applied BRISK and Turbo BRISK to imaging pulsatile flow in a straight tube. To evaluate the capabilities of Turbo BRISK imaging in more complex dynamic flow fields such as might exist in the human vasculature, an in vitro curved tube model, similar in geometry to the aortic arch, was fabricated and imaged under pulsatile flow conditions. Velocity maps were obtained using conventional VEC and Turbo BRISK (turbo factors 1 through 5). Comparison of the flow fields obtained with each higher order turbo factor showed excellent agreement with conventional VEC with minimal loss of information. Similarly, flow maps showed good agreement with the profiles from a laser Doppler velocimetry model. Turbo-5 BRISK, for example, allowed a 94% savings in imaging time, reducing the conventional imaging time from over 8 min to a near breath-hold imaging period of 31 s. Turbo BRISK shows excellent promise toward the development of a clinical tool to evaluate complex dynamic intravascular flow fields.

  3. Color of turbulence

    CERN Document Server

    Zare, Armin; Georgiou, Tryphon T

    2016-01-01

    Second-order statistics of turbulent flows can be obtained either experimentally or via direct numerical simulations. Statistics reflect fundamentals of flow physics and can be used to develop low-complexity turbulence models. Due to experimental or numerical limitations it is often the case that only partial flow statistics can be reliably known, i.e., only certain correlations between a limited number of flow field components are available. Thus, it is of interest to complete the statistical signature of the flow field in a way that is consistent with the known dynamics. This is an inverse problem and our approach utilizes stochastically-forced linearization around turbulent mean velocity profile. In general, white-in-time stochastic forcing is not sufficient to explain turbulent flow statistics. In contrast, colored-in-time forcing of the linearized equations allows for exact matching of available correlations. To accomplish this, we develop dynamical models that generate the required stochastic excitation...

  4. Hemodynamic Changes on Color Doppler Flow Imaging and Intravenous Contrast-enhanced Ultrasound for Assessing Transplanted Liver and Early Diagnosis of Complications

    Institute of Scientific and Technical Information of China (English)

    Daozhong HUANG; Yanchao CHEN; Kaiyan LI; Qingping ZHANG

    2008-01-01

    The value of color Doppler flow imaging (CDFI) and intravenous contrast-enhanced ultrasound (CEUS) for assessing the transplanted liver and early diagnosing complications by examining hemodynamic changes was discussed. Seventy-five patients with orthotopic liver transplantation (OLT) underwent CDFI. The following parameters were measured: peak systolic velocity (PS), resistance index (RI) and Doppler perfusion index (DPI) of the hepatic artery (HA), time average velocity (TAV) of portal vein (PV) and velocity of hepatic vein (HV) in different stages post-operation. And 11 patients of them received CEUS. Thirty healthy subjects were enrolled as controls. The results showed that: (1) In 23 patients without obvious complications, TAV of PV within 15 days post-operation was significantly higher than in controls (P<0.05), PS and DPI of HA within 7 days postoperation were lower, but RI was higher than in controls (P<0.05); (2) When the hepatic artery thrombosis (HAT) occurred, PS and DPI of HA were obviously decreased, but TAV of PV significantly increased like a high saw-tooth wave; (3) While rejection occurred, both TAV of PV and PS of HA were decreased with the increase in RI of HA, and the triphasic wave of HV disappeared and displayed as saw-tooth wave; (4) The incidence of biliary complications in liver transplantation was in-creased when DPI was reduced; (5) Seven cases of hepatic carcinoma relapse after OLT demonstrated hyperecho in the arterial phase and hypoecho in the portal and later phase on CEUS; (6) In 2 cases of HA thrombus, there was no visualized enhancement in arterial phase of CEUS, but enhancement during the portal vein and parenchymal phase. It was concluded that the hemodynamic changes of PV, HA and HV in the transplanted liver are valuable for assessing the transplanted liver and early diagnosing complications on CDFI and CEUS.

  5. Color constancy

    National Research Council Canada - National Science Library

    Foster, David H

    2011-01-01

    ... despite changes in the spectrum of the illumination. At about the same time, new models of color constancy appeared, along with physiological data on cortical mechanisms and photographic colorimetric measurements of natural scenes...

  6. Balancing practicality and hydrologic realism: a parsimonious approach for simulating rapid groundwater recharge via unsaturated-zone preferential flow

    Science.gov (United States)

    Mirus, Benjamin B.; Nimmo, J.R.

    2013-01-01

    The impact of preferential flow on recharge and contaminant transport poses a considerable challenge to water-resources management. Typical hydrologic models require extensive site characterization, but can underestimate fluxes when preferential flow is significant. A recently developed source-responsive model incorporates film-flow theory with conservation of mass to estimate unsaturated-zone preferential fluxes with readily available data. The term source-responsive describes the sensitivity of preferential flow in response to water availability at the source of input. We present the first rigorous tests of a parsimonious formulation for simulating water table fluctuations using two case studies, both in arid regions with thick unsaturated zones of fractured volcanic rock. Diffuse flow theory cannot adequately capture the observed water table responses at both sites; the source-responsive model is a viable alternative. We treat the active area fraction of preferential flow paths as a scaled function of water inputs at the land surface then calibrate the macropore density to fit observed water table rises. Unlike previous applications, we allow the characteristic film-flow velocity to vary, reflecting the lag time between source and deep water table responses. Analysis of model performance and parameter sensitivity for the two case studies underscores the importance of identifying thresholds for initiation of film flow in unsaturated rocks, and suggests that this parsimonious approach is potentially of great practical value.

  7. Color tejido

    OpenAIRE

    Rius Tormo, Palmira

    2010-01-01

    Póster presentado en el IX Congreso Nacional del Color, Alicante, 29-30 junio, 1-2 julio 2010. La exposición que se propone tiene como núcleo principal el color y muestra las posibilidades expresivas que aporta a los diferentes materiales. Las 7 obras presentadas buscan la armonía estética y la fuerza simbólica.

  8. Controllable Microdroplet Splitting via Additional Lateral Flow and its Application in Rapid Synthesis of Multi-scale Microspheres

    KAUST Repository

    Zhou, Bingpu

    2015-01-01

    In this paper, we demonstrate that controllable microdroplet splitting could be obtained via additional lateral flow with simplicity and high controllability. The volume ratio of the two splitting products can be flexibly regulated by adjusting the flow rate ratio between the main and additional lateral flows. The splitting phenomena under different main flow rates were investigated. A volume ratio up to 200 : 1 of the two daughter droplets under a relatively higher main flow rate was experimentally achieved based on our approach. In this case, we have successfully achieved uniform daughter droplets with a smallest diameter of ∼19.5 ± 1.6 μm. With such a design, we have synthesized uniform PEGDA hydrogel microspheres with diameters ranging from ∼30 μm to over hundred of micrometers simultaneously.

  9. Color vision.

    Science.gov (United States)

    Gegenfurtner, Karl R; Kiper, Daniel C

    2003-01-01

    Color vision starts with the absorption of light in the retinal cone photoreceptors, which transduce electromagnetic energy into electrical voltages. These voltages are transformed into action potentials by a complicated network of cells in the retina. The information is sent to the visual cortex via the lateral geniculate nucleus (LGN) in three separate color-opponent channels that have been characterized psychophysically, physiologically, and computationally. The properties of cells in the retina and LGN account for a surprisingly large body of psychophysical literature. This suggests that several fundamental computations involved in color perception occur at early levels of processing. In the cortex, information from the three retino-geniculate channels is combined to enable perception of a large variety of different hues. Furthermore, recent evidence suggests that color analysis and coding cannot be separated from the analysis and coding of other visual attributes such as form and motion. Though there are some brain areas that are more sensitive to color than others, color vision emerges through the combined activity of neurons in many different areas.

  10. Ecografia transfontanelar com fluxo a cores em recém-nascidos prematuros Intracranial blood flow velocities evaluated by color doppler (duplex in preterm infants

    Directory of Open Access Journals (Sweden)

    Marcelo Cardoso de Assis

    2004-03-01

    intracranial hemorrhage. They were subjected to sequencial measurements of blood flow velocities in the intracranial arteries. The gestational age of the whole group varied from 28 to 36 weeks and birth weights between 720 and 2530 g. The diagnosis of the intracerebral hemorrhages in these preterm neonates were done using high resolution gray and color scale transfontanellar ultrasonography brain scans . The ultrasound evaluations were performed in the initial 3rd, 7th and 14th day of life. The 73 preterm infants were evaluated with sequencial measurements of blood flow velocity in the intracranial arteries using the Doppler technique through the anterior fontanelle. Doppler evaluation of the cerebral vessels were performed on days 3, 7, 30 and 90 of life. These evaluations were performed in the six intracranial arteries, meaning: right and left anterior and middle cerebral arteries and right and left internal carotid arteries. Doppler recordings were made using Duplex Color-Doppler system, pulse echo probe of 3,5; 5,0 and 7,5 MHz. Measuring the blood flow velocity in the cerebral arteries we obtained a maximum systolic velocity and end diastolic velocity with a rate in meters per second (m/s for each cardiac cycle. After obtaining these numerical values for these velocities we obtained the resistance index (RI or Pourcelot index. In a progressive way as the resistance index (RI values were being obtained in each stage of this study they were also being checked in the cerebral arteries of healthy preterm infants and infants with intracranial hemorrhages. We also analyzed in a comparative method the values of the resistive index between the two groups of preterm infants observing their behaviour.The results obtained when comparing the RI values in the various arteries during the different stages of the study permitted us to conclude that the RI values of healthy pre-term infants were always larger than the RI values of pre-term infants with intracranial hemorrhage. We also

  11. Rapid Multiplexed Flow Cytometric Assay for Botulinum Neurotoxin Detection Using an Automated Fluidic Microbead-Trapping Flow Cell for Enhanced Sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Ozanich, Richard M.; Bruckner-Lea, Cindy J.; Warner, Marvin G.; Miller, Keith D.; Antolick, Kathryn C.; Marks, James D.; Lou, Jianlong; Grate, Jay W.

    2009-07-15

    A bead-based sandwich immunoassay for botulinum neurotoxin serotype A (BoNT/A) has been developed and demonstrated using a recombinant 50 kDa fragment (BoNT/A-HC-fragment) of the BoNT/A heavy chain (BoNT/A-HC) as a structurally valid simulant. Three different anti-BoNT/A antibodies were attached to three different fluorescent dye encoded flow cytometry beads for multiplexing. The assay was conducted in two formats: a manual microcentrifuge tube format and an automated fluidic system format. Flow cytometry detection was used for both formats. The fluidic system used a novel microbead-trapping flow cell to capture antibody-coupled beads with subsequent sequential perfusion of sample, wash, dye-labeled reporter antibody, and final wash solutions. After the reaction period, the beads were collected for analysis by flow cytometry. Sandwich assays performed on the fluidic system gave median fluorescence intensity signals on the flow cytometer that were 2-4 times higher than assays performed manually in the same amount of time. Limits of detection were estimated at 1 pM (~50 pg/mL for BoNT/A-HC-fragment) for the 15 minute fluidic assay.

  12. Color vision test

    Science.gov (United States)

    ... present from birth) color vision problems: Achromatopsia -- complete color blindness , seeing only shades of gray Deuteranopia -- difficulty telling ... Vision test - color; Ishihara color vision test Images Color blindness tests References Bowling B. Hereditary fundus dystrophies. In: ...

  13. Modeling human color categorization: Color discrimination and color memory

    NARCIS (Netherlands)

    Heskes, T.; van den Broek, Egon; Lucas, P.; Hendriks, Maria A.; Vuurpijl, L.G.; Puts, M.J.H.; Wiegerinck, W.

    2003-01-01

    Color matching in Content-Based Image Retrieval is done using a color space and measuring distances between colors. Such an approach yields non-intuitive results for the user. We introduce color categories (or focal colors), determine that they are valid, and use them in two experiments. The experim

  14. Modeling human color categorization: Color discrimination and color memory

    NARCIS (Netherlands)

    Heskes, T.; van den Broek, Egon; Lucas, P.; Hendriks, Maria A.; Vuurpijl, L.G.; Puts, M.J.H.; Wiegerinck, W.

    2003-01-01

    Color matching in Content-Based Image Retrieval is done using a color space and measuring distances between colors. Such an approach yields non-intuitive results for the user. We introduce color categories (or focal colors), determine that they are valid, and use them in two experiments. The

  15. Color superconductivity

    Energy Technology Data Exchange (ETDEWEB)

    Wilczek, F. [Institute for Advanced Study, Princeton, NJ (United States)

    1997-09-22

    The asymptotic freedom of QCD suggests that at high density - where one forms a Fermi surface at very high momenta - weak coupling methods apply. These methods suggest that chiral symmetry is restored and that an instability toward color triplet condensation (color superconductivity) sets in. Here I attempt, using variational methods, to estimate these effects more precisely. Highlights include demonstration of a negative pressure in the uniform density chiral broken phase for any non-zero condensation, which we take as evidence for the philosophy of the MIT bag model; and demonstration that the color gap is substantial - several tens of MeV - even at modest densities. Since the superconductivity is in a pseudoscalar channel, parity is spontaneously broken.

  16. 多普勒超声对阳萎分度诊断的研究%Study of color Doppler flow imaging for the diagnosis of impotence grading

    Institute of Scientific and Technical Information of China (English)

    滕剑波; 玄绪军; 张先东

    2000-01-01

    目的 探讨不同硬度状态阴茎血管血流参数的差异,为阳萎分度诊断提供客观依据.方法 应用多普勒超声检测74例阳萎患者,海绵体注药前后,连续测定海绵体动脉及背动脉收缩期峰值流速(PSV)、舒张期末血流速度(EDV)、阻力指数(RI)和背深静脉血流速度,对比分析不同硬度诸参数的差异及与硬度的关系.结果 多普勒超声根据海绵体动脉PSV减小及EDV升高,并同硬度结合可以推断海绵体动脉和静脉异常;海绵体动脉PSV、EDV、RI在不同硬度有显著性差异(P<0.05),RI与硬度密切相关(r's=0.7948,P<0.01),可作为阳萎分度诊断的客观指标.结论 多普勒超声是阳萎分度诊断有价值的检查手段.%Objective To studly the difference of penile vascular parameters under different penis stiffness state in order to provide objective information for diagnosis of impotence grading. Methods Seventy-four cases of impotence patients were examined by color Doppler flow imaging (CDFI). Before and after drug injection of cavemosum,the 5SV,EDV,RI of cavernosal artery and velocity of dorsal vein were measured continously at the time interval of 5 min,and were compared with penis stiffness state. The difference of the vascular parameters and the correlation between the vascular parameters and penis stiffness were analysed under different penis stiffness. Results By combinating the PSV decrease and EDV increase of cavernosal artery with penis stiffness, the abnormalities of cavernosal artery and dorsal vein may be found. Under different penis stiffness state the PSV, EDV,RI o"f cavernosal artery have significant difference ( P <0.05). The RI correlated closely with the penis stiffness state ( r',= 0.7948). RI may provide objective data for the diagnosis of impotence grading. Conclusions CDFI is regarded as the valuable method in the diagnosis of impotence grading.

  17. Rapid geomorphic change caused by glacial outburst floods and debris flows along Tahoma Creek, Mount Rainier, Washington, USA

    Science.gov (United States)

    Walder, J.S.; Driedger, C.L.

    1994-01-01

    As part of a hazards-assessment study, we examined the nature and rate of geomorphic change caused by outburst floods and debris flows along Tahoma Creek. Mount Rainier, since 1967. Archival aerial photographs of the area proved to be a rich source of qualitative geomorphic information. On the basis of limited direct evidence and considerations of stream hydrology, we conclude that nearly all of these debris flows began as outburst floods from South Tahoma Glacier. The water floods transformed to debris flows by incorporating large masses of sediment in a 2-km-long channel reach where the stream has incised proglacial sediments and debris-rich, stagnant glacier ice. Comparison of topographic maps for 1970 and 1991 shows that the average sediment flux out of the incised reach has been about 2 to 4 × 105 m3 a-1 corresponding to an average denudation rate in the upper part of the Tahoma Creek drainage basin of about 20 to 40 mm a-1, a value exceeded only rarely in basins affected by debris flows. However, little of this sediment has yet passed out of the Tahoma Creek basin. Comparison of geomorphic change at Tahoma Creek to that in two other alpine basins affected by outburst floods suggests that debris-rich stagnant ice can be an important source of sediment for debris flows as long as floods are frequent or channel slope is great.

  18. Two-dimensionalization of the flow driven by a slowly rotating impeller in a rapidly rotating fluid

    CERN Document Server

    Machicoane, Nathanaël; Cortet, Pierre-Philippe

    2016-01-01

    We characterize the two-dimensionalization process in the turbulent flow produced by an impeller rotating at a rate $\\omega$ in a fluid rotating at a rate $\\Omega$ around the same axis for Rossby number $Ro=\\omega/\\Omega$ down to $10^{-2}$. The flow can be described as the superposition of a large-scale vertically invariant global rotation and small-scale shear layers detached from the impeller blades. As $Ro$ decreases, the large-scale flow is subjected to azimuthal modulations. In this regime, the shear layers can be described in terms of wakes of inertial waves traveling with the blades, originating from the velocity difference between the non-axisymmetric large-scale flow and the blade rotation. The wakes are well defined and stable at low Rossby number, but they become disordered at $Ro$ of order of 1. This experiment provides insight into the route towards pure two-dimensionalization induced by a background rotation for flows driven by a non-axisymmetric rotating forcing.

  19. Evaluation of Flow-Injection Tandem Mass Spectrometry for Rapid and High-Throughput Quantitative Determination of B-Vitamins in Nutritional Supplements

    Energy Technology Data Exchange (ETDEWEB)

    Bhandari, Deepak [ORNL; Van Berkel, Gary J [ORNL

    2012-01-01

    The use of flow-injection electrospray ionization tandem mass spectrometry for rapid and high-throughput mass spectral analysis of selected B-vitamins, viz. B1, B2, B3, B5, and B6, in nutritional formulations was demonstrated. A simple and rapid (~5 min) in-tube sample preparation was performed by adding extraction solvent to a powdered sample aliquot followed by agitation, centrifugation, and filtration to recover an extract for analysis. Automated flow injection introduced 1 L of the extracts directly into the mass spectrometer ion source without chromatographic separation. Sample-to-sample analysis time was 60 s representing significant improvement over conventional liquid chromatography approaches which typically require 25-45 min, and often require more significant sample preparation procedures. Quantitative capabilities of the flow-injection analysis were tested using the method of standard additions and NIST standard reference material (SRM 3280) multivitamin/multielement tablets. The quantity determined for each B-vitamin in SRM 3280 was within the statistical range provided for the respective certified values. The same sample preparation and analysis approach was also applied to two different commercial vitamin supplement tablets and proved to be successful in the quantification of the selected B-vitamins as evidenced by an agreement with the labels values and the results obtained using isotope dilution liquid chromatography/mass spectrometry.

  20. Color doppler sonography in thickened gallbladder wall

    Energy Technology Data Exchange (ETDEWEB)

    Han, Sang Suk; Choi, Seok Jin; Seo, Chang Hae; Eun, Choong Ki [Inje Univ. College of Medicine, Kimhae (Korea, Republic of)

    1996-11-01

    The thickening of the gallbladder wall is a valuable finding for the diagnosis of cholecystitis, but may be seen in non-cholecystic disease as well as in acute or chronic cholecystitis. The purpose of this study is to determine the value of color Doppler sonography in differentiating the causes of thickened gallbladder wall. Ninety eight patients with thickened gallbladder wall(more than 3mm) which was not due to gallbladder cancer were prospectively evaluated with color Doppler sonography. Sixty-six cases, confirmed by pathologic reports and clinical records, were analyzed for correlation between thickened gallbladder wall and color flow signal according to the underlying causes. Of the 66 patients, 28 cases were cholecystitis and 38 cases had non-cholecystic causes such as liver cirrhosis, ascites, hepatitis, pancreatitis, renal failure, and hypoalbuminemia. Of the 28 patients with cholecystitis(12 acute, 16 chronic), 23(82%) had color Doppler flow signals in the thickened gallbladder wall. Of the 38 patients with non-cholecystic causes, eight(21%) had color Doppler flow signals. There was a statistically significant difference of color Doppler flow signals between the cholecystitis and non-cholecystic groups(p=0.0001). No significant difference of color Doppler flow signals was found between cases of acute and chronic cholecystitis. Of the 23 patients with color Doppler flow signals in 28 cases of cholecystitis, 18(78.3%) showed a linear pattern and five(21.7%) showed a spotty pattern. Of the eight patients with color Doppler flow signals in the 38 non-cholecystic cases, four(50%) showed a linear pattern and four(50%) showed a spotty pattern. In cholecystitis, a linear color Doppler flow signal pattern is a much more frequent finding than a spotty pattern. Color Doppler sonography is a useful and adequate method for determining whether a thickened gallbladder wall is the result of cholecystitis or has non-cholecystic causes.

  1. Reproducibility of the International Endometrial Analysis Group Color Score for Assigning the Amount of Flow Within the Endometrium Using Stored 3-Dimensional Volumes.

    Science.gov (United States)

    Alcázar, Juan Luis; Pascual, María Ángela; Ajossa, Silvia; de Lorenzo, Cristina; Piras, Alba; Hereter, Lourdes; Juez, Leire; Fabbri, Paola; Graupera, Betlem; Guerriero, Stefano

    2017-07-01

    To estimate intraobserver and interobserver reproducibility for assigning an International Endometrial Tumor Analysis (IETA) group color score for endometrial vascularization on color Doppler imaging. Sixty-eight endometrial 3-dimensional volumes from endometrial color Doppler assessments of women with different endometrial disorders were evaluated by 8 different examiners (4 skilled examiners and 4 obstetric and gynecologic trainees). One skilled examiner who did not participate in the assessments selected the 68 volumes from a database to select a balanced number of each IETA score. Each examiner evaluated the 68 endometrial volumes to assign the IETA color score (1, absence of vascularization; 2, low vascularization; 3, moderate vascularization; or 4, abundant vascularization) using tomographic ultrasound imaging. The analysis was repeated 4 weeks later, and interobserver and intraobserver reproducibility was analyzed by calculating the weighted κ index. The second of the measurements made by each observer was used to estimate interobserver reproducibility. The intraobserver reproducibility was very good for all examiners, with a weighted κ index ranging from 0.84 to 0.91. The interobserver reproducibility was good or very good for all estimated comparisons, with a weighted κ index ranging from 0.77 to 0.96, regardless of experience level. The reproducibility of assigning the IETA color score for assessing endometrial vascularization using 3-dimensional volumes is good or very good regardless of the experience of the examiner. © 2017 by the American Institute of Ultrasound in Medicine.

  2. Rapid multiplex detection of 10 foodborne pathogens with an up-converting phosphor technology-based 10-channel lateral flow assay.

    Science.gov (United States)

    Zhao, Yong; Wang, Haoran; Zhang, Pingping; Sun, Chongyun; Wang, Xiaochen; Wang, Xinrui; Yang, Ruifu; Wang, Chengbin; Zhou, Lei

    2016-02-17

    The rapid high-throughput detection of foodborne pathogens is essential in controlling food safety. In this study, a 10-channel up-converting phosphor technology-based lateral flow (TC-UPT-LF) assay was established for the rapid and simultaneous detection of 10 epidemic foodborne pathogens. Ten different single-target UPT-LF strips were developed and integrated into one TC-UPT-LF disc with optimization. Without enrichment the TC-UPT-LF assay had a detection sensitivity of 10(4) CFU mL(-1) or 10(5) CFU mL(-1) for each pathogen, and after sample enrichment it was 10 CFU/0.6 mg. The assay also showed good linearity, allowing quantitative detection, with a linear fitting coefficient of determination (R(2)) of 0.916-0.998. The 10 detection channels did not cross-react, so multiple targets could be specifically detected. When 279 real food samples were tested, the assay was highly consistent (100%) with culture-based methods. The results for 110 food samples artificially contaminated with single or multiple targets showed a high detection rate (≥ 80%) for most target bacteria. Overall, the TC-UPT-LF assay allows the rapid, quantitative, and simultaneous detection of 10 kinds of foodborne pathogens within 20 min, and is especially suitable for the rapid detection and surveillance of foodborne pathogens in food and water.

  3. Development of a Flow Cytometry-Based Method for Rapid Detection of Escherichia coli and Shigella Spp. Using an Oligonucleotide Probe.

    Science.gov (United States)

    Xue, Yong; Wilkes, Jon G; Moskal, Ted J; Williams, Anna J; Cooper, Willie M; Nayak, Rajesh; Rafii, Fatemeh; Buzatu, Dan A

    2016-01-01

    Standard methods to detect Escherichia coli contamination in food use the polymerase chain reaction (PCR) and agar culture plates. These methods require multiple incubation steps and take a long time to results. An improved rapid flow-cytometry based detection method was developed, using a fluorescence-labeled oligonucleotide probe specifically binding a16S rRNA sequence. The method positively detected 51 E. coli isolates as well as 4 Shigella species. All 27 non-E. coli strains tested gave negative results. Comparison of the new genetic assay with a total plate count (TPC) assay and agar plate counting indicated similar sensitivity, agreement between cytometry cell and colony counts. This method can detect a small number of E.coli cells in the presence of large numbers of other bacteria. This method can be used for rapid, economical, and stable detection of E. coli and Shigella contamination in the food industry and other contexts.

  4. Development of a Flow Cytometry-Based Method for Rapid Detection of Escherichia coli and Shigella Spp. Using an Oligonucleotide Probe.

    Directory of Open Access Journals (Sweden)

    Yong Xue

    Full Text Available Standard methods to detect Escherichia coli contamination in food use the polymerase chain reaction (PCR and agar culture plates. These methods require multiple incubation steps and take a long time to results. An improved rapid flow-cytometry based detection method was developed, using a fluorescence-labeled oligonucleotide probe specifically binding a16S rRNA sequence. The method positively detected 51 E. coli isolates as well as 4 Shigella species. All 27 non-E. coli strains tested gave negative results. Comparison of the new genetic assay with a total plate count (TPC assay and agar plate counting indicated similar sensitivity, agreement between cytometry cell and colony counts. This method can detect a small number of E.coli cells in the presence of large numbers of other bacteria. This method can be used for rapid, economical, and stable detection of E. coli and Shigella contamination in the food industry and other contexts.

  5. A rapid quenched-flow device for the characterisation of the nascent polymerisation of ethylene under industrial conditions

    NARCIS (Netherlands)

    Di Martino, A.; Di Martino, Audrey; Broyer, Jean Pierre; Spitz, Roger; Weickert, G.; McKenna, Timothy F.

    2005-01-01

    A quenched-flow reactor is introduced as an effective means for the production of polyolefin particles with precisely controlled reaction times as low as 40 ms. The use of off-line scanning electron microscopy and induced-coupled plasma yields experimental data on the development of the kinetics and

  6. On the fabrication of PDMS micromodels by rapid prototyping, and their use in two-phase flow studies

    NARCIS (Netherlands)

    Karadimitriou, N.K.; Musterd, M.; Kleingeld, P.J.; Kreutzer, M.T.; Hassanizadeh, S.M.; Joekar-Niasar, V.

    2013-01-01

    Micromodels have been increasingly employed in various ways in porous media research, to study the pore-scale behavior of fluids. Micromodels have proven to be a valuable tool by allowing the observation of flow and transport at the micron scale in chemical, biological, and physical applications. Th

  7. A Rapid Quenched-Flow Device for the Characterisation of the Nascent Polymerisation of Ethylene under Industrial Conditions

    NARCIS (Netherlands)

    Di Martino, Audrey; Broyer, Jean Pierre; Spitz, Roger; Weickert, Günter; McKenna, Timothy F.

    2005-01-01

    A quenched-flow reactor is introduced as an effective means for the production of polyolefin particles with precisely controlled reaction times as low as 40 ms. The use of off-line scanning electron microscopy and induced-coupled plasma yields experimental data on the development of the kinetics and

  8. Immunochromatographic Lateral-flow test strip for the rapid detection of added bovine rennet whey in milk and milk powder

    NARCIS (Netherlands)

    Martin-Hernandez, C.; Munoz, M.; Daury, C.; Weymuth, H.; Kemmers-Voncken, A.; Corbation, V.; Toribo, T.; Bremer, M.G.E.G.

    2009-01-01

    An immunochromatographic lateral-flow test dipstick test was developed for the fast detection of bovine rennet whey in liquid milk and milk powder. The test is based on the binding of casein glycomacropeptide (cGMP) by two specific anti-bovine ¿-casein monoclonal antibodies and has a visual detectio

  9. Colored Preons

    CERN Document Server

    Finkelstein, Robert J

    2009-01-01

    Previous studies have suggested complementary models of the elementary particles as (a) quantum knots and (b) preonic nuclei that are field and particle descriptions, respectively, of the same particles. This earlier work, carried out in the context of standard electroweak (SU(2) x U(1)) physics, is here extended to the strong interactions by the introduction of color (SU(3)) charges.

  10. Color Sense

    Science.gov (United States)

    Johnson, Heidi S. S.; Maki, Jennifer A.

    2009-01-01

    This article reports a study conducted by members of the WellU Academic Integration Subcommittee of The College of St. Scholastica's College's Healthy Campus Initiative plan whose purpose was to determine whether changing color in the classroom could have a measurable effect on students. One simple improvement a school can make in a classroom is…

  11. A flowing liquid test system for assessing the linearity and time-response of rapid fibre optic oxygen partial pressure sensors.

    Science.gov (United States)

    Chen, R; Hahn, C E W; Farmery, A D

    2012-08-15

    The development of a methodology for testing the time response, linearity and performance characteristics of ultra fast fibre optic oxygen sensors in the liquid phase is presented. Two standard medical paediatric oxygenators are arranged to provide two independent extracorporeal circuits. Flow from either circuit can be diverted over the sensor under test by means of a system of rapid cross-over solenoid valves exposing the sensor to an abrupt change in oxygen partial pressure, P O2. The system is also capable of testing the oxygen sensor responses to changes in temperature, carbon dioxide partial pressure P CO2 and pH in situ. Results are presented for a miniature fibre optic oxygen sensor constructed in-house with a response time ≈ 50 ms and a commercial fibre optic sensor (Ocean Optics Foxy), when tested in flowing saline and stored blood.

  12. Impartial coloring games

    CERN Document Server

    Beaulieu, Gabriel; Duchêne, Eric

    2012-01-01

    Coloring games are combinatorial games where the players alternate painting uncolored vertices of a graph one of $k > 0$ colors. Each different ruleset specifies that game's coloring constraints. This paper investigates six impartial rulesets (five new), derived from previously-studied graph coloring schemes, including proper map coloring, oriented coloring, 2-distance coloring, weak coloring, and sequential coloring. For each, we study the outcome classes for special cases and general computational complexity. In some cases we pay special attention to the Grundy function.

  13. Rapid freezing cryo-polymerization and microchannel liquid-flow focusing for cryogel beads: adsorbent preparation and characterization of supermacroporous bead-packed bed.

    Science.gov (United States)

    Yun, Junxian; Dafoe, Julian T; Peterson, Eric; Xu, Linhong; Yao, Shan-Jing; Daugulis, Andrew J

    2013-04-05

    Cryogel beads, fabricated by the microchannel liquid-flow focusing and cryo-polymerization method, have micron-scale supermacropores allowing the passage of crude feedstocks, and could be of interest as chromatographic adsorbents in bioseparation applications. In this work, we provide a rapid freezing and continuous formation method for cryogel beads by cryo-polymerization using dry ice particles as the freezing source and microchannel liquid-flow focusing using peristaltic pumps for the fluid supply. Polyacrylamide (pAAm)-based supermacroporous cryogel beads were prepared and grafted with N,N-dimethylaminoethyl methacrylate (DMAEMA), which provided the anion-exchange cryogel beads with tertiary amine functional groups suitable for binding proteins. Properties of the supermacroporous cryogel-bead packed bed, i.e., permeability, bed voidage, protein breakthrough as well as protein adsorption performance by using bovine γ-globulin as model protein, were experimentally investigated. A capillary-based model was employed to characterize the supermacroporous bed performance, and gave a reasonable description of the microstructure and thus an insight into the flow, dispersion and mass transfer behaviors within the cryogel bead-packed bed. The results also showed that by using dry ice as the freezing source, it is easy to reduce the temperature below -55 to -61°C in the bulk solution, causing the rapid formation of ice crystals within the monomer drops, and finally effective cryo-polymerization to form supermacropores within the cryogel beads. By using peristaltic pumps, continuous preparation was achieved and the obtained cryogel beads had favorable properties similar to those prepared using syringe pumps in the microchannel liquid-flow focusing process. This method is thus expected to be interesting in the liter- or even larger-scale preparation of cryogel adsorbents.

  14. Numerical modelling of rapid, flow-like landslides across 3-D terrains: a Tsunami Squares approach to El Picacho landslide, El Salvador, September 19, 1982

    Science.gov (United States)

    Wang, Jiajia; Ward, Steven N.; Xiao, Lili

    2015-06-01

    Flow-like landslides are rapidly moving fluid-solid mixtures that can cause significant destruction along paths that run far from their original sources. Existing models for run out prediction and motion simulation of flow-like landslides have many limitations. In this paper, we develop a new method named `Tsunami Squares' to simulate the generation, propagation and stoppage of flow-like landslides based on conservation of volume and momentum. Landslide materials in the new method form divisible squares that are displaced, then further fractured. The squares move under the influence of gravity-driven acceleration and suffer decelerations due to basal and dynamic frictions. Distinctively, this method takes into account solid and fluid mechanics, particle interactions and flow regime transitions. We apply this approach to simulate the 1982 El Picacho landslide in San Salvador, capital city of El Salvador. Landslide products from Tsunami Squares such as run out distance, velocities, erosion and deposition depths and impacted area agree well with field investigated and eyewitness data.

  15. Flow Injection/Sequential Injection Analysis Systems: Potential Use as Tools for Rapid Liver Diseases Biomarker Study

    Directory of Open Access Journals (Sweden)

    Supaporn Kradtap Hartwell

    2012-01-01

    Full Text Available Flow injection/sequential injection analysis (FIA/SIA systems are suitable for carrying out automatic wet chemical/biochemical reactions with reduced volume and time consumption. Various parts of the system such as pump, valve, and reactor may be built or adapted from available materials. Therefore the systems can be at lower cost as compared to other instrumentation-based analysis systems. Their applications for determination of biomarkers for liver diseases have been demonstrated in various formats of operation but only a few and limited types of biomarkers have been used as model analytes. This paper summarizes these applications for different types of reactions as a guide for using flow-based systems in more biomarker and/or multibiomarker studies.

  16. A simple and rapid flow cytometry-based assay to identify a competent embryo prior to embryo transfer

    OpenAIRE

    Pallinger, Eva; Bognar, Zoltan; Bodis, Jozsef; Csabai, Timea; Farkas, Nelli; Godony, Krisztina; Varnagy, Akos; Buzas, Edit; Szekeres-Bartho, Julia

    2017-01-01

    Multiple pregnancy is a risk for prematurity and preterm birth. The goal of assisted reproduction is to achieve a single pregnancy, by transferring a single embryo. This requires improved methods to identify the competent embryo. Here, we describe such a test, based on flow cytometric determination of the nucleic acid (PI+) containing extracellular vesicle (EV) count in day 5 embryo culture media. 88 women undergoing IVF were included in the study. More than 1 embryos were transferred to most...

  17. Value of systolic pulmonary venous flow reversal and color Doppler jet measurements assessed with transesophageal echocardiography in recognizing severe pure mitral regurgitation

    NARCIS (Netherlands)

    Pieper, EPG; Hellemans, IM; Hamer, HPM; Ravelli, ACJ; Cheriex, EC; Tijssen, JGP; Lie, KI; Visser, CA

    1996-01-01

    We evaluated the value of color and pulsed Doppler transesophageal echocardiographic parameters and of V waves in estimating the severity of mitral regurgitation (MR) in 62 consecutive patients (38 men and 24 women, aged 39 to 80 years) with angiographically proven chronic pure MR (15 grade I/II, 47

  18. 彩色多普勒超声在早产儿视网膜病变中应用%Application of color Doppler flow imaging in retinopathy of prematurity

    Institute of Scientific and Technical Information of China (English)

    陈洁玲; 邹丽娟; 吴京红; 赵华飞; 吴中耀

    2011-01-01

    Objective To observe ultrasound characteristics in stage Ⅴ retinopathy of prematurity.Methods All 80 patients (150 eyes) with retinopathy of prematurity were examined with color Doppler flow imaging (CDFI). The morphologic characteristics of color Doppler flow imaging and blood stream were observed in patients with retinopathy of prematurity. Results Among 150 eyes with retinopathy of prernaturity at stage Ⅴ, there were 80 patients in whom we observed that lump-like echo connected closely with echo of lens and the circumambience was surrounded and the zonal echo was attached to the optic disc. The features of blood flow showed the signal of blood stream connected with central retinal vessels, which was analyzed by Doppler spectrum as the blood-flow spectrum like sand-heap. Conclusions The morphologic changes of color Doppler flow imaging and the features of blood flow are useful in diagnosis of retinopathy of prematurity patients at the stageⅤ.%目的 观察5期早产儿视网膜病变的超声显像特征.方法 用彩色多普勒超声诊断仪检查80例(150只眼)于眼科临床检查发现异常的早产患儿,并观察彩色多普勒血流成像(CDFI)形态特点及病变的血流特征.结果 在早产儿患眼超声检查80例(150只眼)眼内显示为与晶状体回声紧密相连并包绕其周围的不规则光团回声,光团与视乳头间条索状光带相连,血流特点表现为条索状光带上显示与视网膜中央血管相延续的血流信号,脉冲多普勒显示沙堆状动脉血流频谱特征.结论 彩色多普勒超声能清晰显示5期早产儿视网膜病变的超声显像特征和血流特征,结合临床病史,为诊断提供重要的依据.

  19. Forward-rapidity azimuthal and radial flow of identified particles for $\\sqrt{s_{NN}}$ = 200 GeV Au+Au collisions

    CERN Document Server

    Sanders, S J

    2009-01-01

    A strong azimuthal flow signature at RHIC suggests rapid system equilibration leading to an almost perfect fluid state. The longitudinal extent of the flow behavior depends on how this state is formed and can be studied by measuring the pseudorapidity and transverse momentum dependence of the second Fourier component ($v_{2}(p_{T})$) of the azimuthal angular distribution. We report on a measurement of identified-particle $v_{2}$ as a function of $p_{T}$ (0.5-2.0 GeV/c), centrality (0-25%, 25-50%), and pseudorapidity ($0\\leq\\eta<3.2$) for $\\sqrt{s_{NN}} = 200 \\rm GeV$ Au+Au collisions. The BRAHMS spectrometers are used for particle identification ($\\pi$, K, p) and momentum determination and the BRAHMS global detectors are used to determine the corresponding reaction-plane angles. The results are discussed in terms of the rapidity dependence of constituent quark scaling and in terms of models that develop the complete (azimuthal and radial) hydrodynamic aspects of the forward dynamics at RHIC.

  20. How low can they go when going with the flow? Tolerance of egg and larval fishes to rapid decompression

    Energy Technology Data Exchange (ETDEWEB)

    Boys, Craig A.; Robinson, Wayne; Miller, Brett; Pflugrath, Brett; Baumgartner, Lee J.; Navarro, Anna; Brown, Richard; Deng, Zhiqun

    2016-05-26

    Egg and larval fish that drift downstream are likely to encounter river infrastructure and consequently rapid decompression, which may result in significant injury. In juvenile fish, pressure-related injury (or barotrauma) occurs when pressures fall sufficiently below the pressure at which the fish has acclimated. Because eggs and larvae are less-developed and more fragile than juveniles, there is a presumption that they may be at least as, if not more, susceptible to barotrauma injury, but studies to date report inconsistent results and none have considered the relationship between pressure change and barotrauma over a sufficiently broad range of pressure changes to enable detrimental levels to be properly determined. To address this, we exposed eggs and larvae of three physoclistic species to rapid decompression in a barometric chamber over a broad range of discrete pressure changes. Eggs, but not larvae, were unaffected by all levels of decompression tested. At exposure pressures below ~40 kPa, or ~40% of atmospheric pressure, swim bladder deflation occurred in all species and internal haemorrhage was observed in one species. None of these injuries killed the fish within 24 hours, but subsequent mortality cannot be excluded. Consequently, if larval drift is expected, it seems prudent to maintain exposure pressures at river infrastructure at 40% or more of the pressure to which a drifting larvae has acclimated.

  1. A Simple and Rapid Method for Quality Control of Major Histocompatibility Complex-Peptide Monomers by Flow Cytometry.

    Science.gov (United States)

    Chandran, P Anoop; Heidu, Sonja; Zelba, Henning; Schmid-Horch, Barbara; Rammensee, Hans-Georg; Pascolo, Steve; Gouttefangeas, Cécile

    2017-01-01

    Major histocompatibility complex (MHC) multimers are essential tools in T cell immunomonitoring, which are employed both in basic and clinical research, as well as for assessing clinical samples during therapy. The generation of MHC monomers loaded with synthetic peptides is an elaborate and time-consuming process. It would be beneficial to assess the quality of these monomers prior to downstream applications. In this technical note, we describe a novel flow cytometry-based, cell-free, quick, and robust assay to check the quality of MHC monomers directly after refolding or after long-term storage.

  2. A Simple and Rapid Method for Quality Control of Major Histocompatibility Complex–Peptide Monomers by Flow Cytometry

    Science.gov (United States)

    Chandran, P. Anoop; Heidu, Sonja; Zelba, Henning; Schmid-Horch, Barbara; Rammensee, Hans-Georg; Pascolo, Steve; Gouttefangeas, Cécile

    2017-01-01

    Major histocompatibility complex (MHC) multimers are essential tools in T cell immunomonitoring, which are employed both in basic and clinical research, as well as for assessing clinical samples during therapy. The generation of MHC monomers loaded with synthetic peptides is an elaborate and time-consuming process. It would be beneficial to assess the quality of these monomers prior to downstream applications. In this technical note, we describe a novel flow cytometry-based, cell-free, quick, and robust assay to check the quality of MHC monomers directly after refolding or after long-term storage. PMID:28228758

  3. Rapid detection of herpes simplex virus in clinical samples by flow cytometry after amplification in tissue culture.

    OpenAIRE

    McSharry, J J; Costantino, R; McSharry, M B; Venezia, R A; Lehman, J M

    1990-01-01

    Murine monoclonal antibodies (MAbs) against herpes simplex virus type 1 and 2 (HSV-1 and -2, respectively) nuclear antigens were used to identify cells infected with HSV-1 or -2 by indirect immunofluorescence in conjunction with flow cytometry after virus amplification of MRC-5 cell monolayers. The results indicate that MAbs Q1, Q2, and H-640 detect HSV-1- and HSV-2-infected cells, MAb SD-1 detects HSV-2- but not HSV-1-infected cells, and MAb 58-S detects HSV-1- but not HSV-2-infected cells. ...

  4. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume ... use of colored contact lenses , from the U.S. Food and Drug Administration (FDA). Are the colored lenses ...

  5. Computational color technology

    CERN Document Server

    Kang, Henry R

    2006-01-01

    Henry Kang provides the fundamental color principles and mathematical tools to prepare the reader for a new era of color reproduction, and for subsequent applications in multispectral imaging, medical imaging, remote sensing, and machine vision. This book is intended to bridge the gap between color science and computational color technology, putting color adaptation, color constancy, color transforms, color display, and color rendition in the domain of vector-matrix representations and theories. Computational Color Technology deals with color digital images on the spectral level using vector-m

  6. Flow cytometry in environmental microbiology: a rapid approach for the isolation of single cells for advanced molecular biology analysis.

    Science.gov (United States)

    Ferrari, Belinda C; Winsley, Tristrom J; Bergquist, Peter L; Van Dorst, Josie

    2012-01-01

    The isolation and subsequent characterization of microbial cells from within environmental samples is a difficult process. Flow cytometry and cell sorting, when combined with the application of fluorescent probes, have the capability for the detection and separation of diverse microbial populations from within complex mixtures. The isolation of single cells allows for downstream investigations towards system-level characterization of unknown Bacterial Phyla to occur. We describe here the combination of fluorescent in situ hybridization and cell sorting for the detection and isolation of Candidate Division TM7 bacteria from an enriched soil sample. The result is the isolation of rare cells suitable for advanced molecular analysis including whole genome amplification and high-throughput pyrosequencing.

  7. Correlation of eruptive products, Volcán Azufral, Colombia: Implications for rapid emplacement of domes and pyroclastic flow units

    Science.gov (United States)

    Williams, Matthew; Bursik, M. I.; Cortes, G. P.; Garcia, A. M.

    2017-07-01

    The eruptive history and morphology of Azufral Volcano, Colombia, is explored and analyzed to provide a more complete picture of past eruptions, as well as to infer what eruption styles may occur in the future. Through the use of principal component analysis on Fe-Ti oxides, domes can be correlated to the pyroclastic deposits, enabling the identification of a full eruptive sequence. The findings suggest that eruptive activity at Azufral Volcano is largely explosive, experiencing long periods of quiescence, punctuated by short periods of pyroclastic activity and volcanic debris avalanches. Geomorphology of the dome complex is reinterpreted to better understand the sequence of dome growth. This reinterpretation, along with geochemical analysis and comparison via PCA, allows for reclassification of a major deposit, originally thought to be a juvenile block-and-ash flow, as a volcanic debris avalanche.

  8. Rapid processing of carbon-carbon composites by forced flow-thermal gradient chemical vapor infiltration (FCVI)

    Energy Technology Data Exchange (ETDEWEB)

    Vaidyaraman, S.; Lackey, W.J.; Agrawal, P.K.; Freeman, G.B.; Langman, M.D. [Georgia Inst. of Tech., Atlanta, GA (United States)

    1995-10-01

    Carbon fiber-carbon matrix composites were fabricated using the forced flow-thermal gradient chemical vapor infiltration (FCVI) process. Preforms were prepared by stacking 40 layers of plain weave carbon cloth in a graphite holder. The preforms were infiltrated using propylene, propane, and methane. The present work showed that the FCVI process is well suited for fabricating carbon-carbon composites; without optimization of the process, the authors have achieved uniform and thorough densification. Composites with porosities as low as 7% were fabricated in 8--12 h. The highest deposition rate obtained in the present study was {approximately}3 {micro}m/h which is more than an order of magnitude faster than the typical value of 0.1--0.25 {micro}m/h for the isothermal process. It was also found that the use of propylene and propane as reagents resulted in faster infiltration compared to methane.

  9. Modelling multi-phase liquid-sediment scour and resuspension induced by rapid flows using Smoothed Particle Hydrodynamics (SPH) accelerated with a Graphics Processing Unit (GPU)

    Science.gov (United States)

    Fourtakas, G.; Rogers, B. D.

    2016-06-01

    A two-phase numerical model using Smoothed Particle Hydrodynamics (SPH) is applied to two-phase liquid-sediments flows. The absence of a mesh in SPH is ideal for interfacial and highly non-linear flows with changing fragmentation of the interface, mixing and resuspension. The rheology of sediment induced under rapid flows undergoes several states which are only partially described by previous research in SPH. This paper attempts to bridge the gap between the geotechnics, non-Newtonian and Newtonian flows by proposing a model that combines the yielding, shear and suspension layer which are needed to predict accurately the global erosion phenomena, from a hydrodynamics prospective. The numerical SPH scheme is based on the explicit treatment of both phases using Newtonian and the non-Newtonian Bingham-type Herschel-Bulkley-Papanastasiou constitutive model. This is supplemented by the Drucker-Prager yield criterion to predict the onset of yielding of the sediment surface and a concentration suspension model. The multi-phase model has been compared with experimental and 2-D reference numerical models for scour following a dry-bed dam break yielding satisfactory results and improvements over well-known SPH multi-phase models. With 3-D simulations requiring a large number of particles, the code is accelerated with a graphics processing unit (GPU) in the open-source DualSPHysics code. The implementation and optimisation of the code achieved a speed up of x58 over an optimised single thread serial code. A 3-D dam break over a non-cohesive erodible bed simulation with over 4 million particles yields close agreement with experimental scour and water surface profiles.

  10. A novel high performance stopped-flow apparatus equipped with a special constructed mixing chamber containing a plunger under inert condition with a very short dead-time to investigate very rapid reactions

    Directory of Open Access Journals (Sweden)

    Sayyed Mostafa Habibi Khorassani

    2015-11-01

    Full Text Available The present work set out to establish a novel stopped-flow instrument equipped with a special constructed mixing chamber containing a plunger to enable a kinetic study of the very rapid reactions under a dry inert atmosphere glove bag, in particular, for the reactions are sensitive to moisture or air. A stopped-flow spectrophotometer is essentially a conventional spectrophotometer with the addition of a system for rapid mixing of solutions. The purpose of this work is to describe the fabrication and evaluation of specially constructed and in-expensive stopped-flow system. The evaluation includes determination of the dead-time, relative mixing efficiency, and the measurement of known rate constants. Herein, a dead-time of about 3.4 ms was determined in the final modified construction of the stopped-flow apparatus in order to investigate the rapid initial during which some form of reaction intermediate is presented to be formed.

  11. Color blindness and Rorschach color responsivity.

    Science.gov (United States)

    Corsino, B V

    1985-10-01

    Color vision deficits occur in 10% of the American white male population. Thus, color blindness may invalidate diagnostic hypotheses generated from Rorschach data. The Rorschach protocols of 43 white, college male color-blind subjects were compared to the protocols of normally sighted controls. The color-blind group manifested fewer pure "C" responses. No significant between group differences emerged for any of the other primary Rorschach color variables. Pure "C" responses rarely figure prominently in Rorschach evaluations, and the apparent lowered frequency of these responses by the color-blind is insufficient to warrant modification of current Rorschach practice. The data suggest that color blindness is unlikely to confound Rorschach assessment.

  12. A simple and rapid flow cytometry-based assay to identify a competent embryo prior to embryo transfer

    Science.gov (United States)

    Pallinger, Eva; Bognar, Zoltan; Bodis, Jozsef; Csabai, Timea; Farkas, Nelli; Godony, Krisztina; Varnagy, Akos; Buzas, Edit; Szekeres-Bartho, Julia

    2017-01-01

    Multiple pregnancy is a risk for prematurity and preterm birth. The goal of assisted reproduction is to achieve a single pregnancy, by transferring a single embryo. This requires improved methods to identify the competent embryo. Here, we describe such a test, based on flow cytometric determination of the nucleic acid (PI+) containing extracellular vesicle (EV) count in day 5 embryo culture media. 88 women undergoing IVF were included in the study. More than 1 embryos were transferred to most patients. In 58 women, the transfer resulted in clinical pregnancy, whereas in 30 women in implantation failure. In 112 culture media of embryos from the “clinical pregnancy” group, the number of PI+ EVs was significantly lower than in those of 49 embryos, from the “implantation failure” group. In 14 women, transfer of a single embryo resulted in a singleton pregnancy, or, transfer of two embryos in twin pregnancy. The culture media of 19 out of the 20 “confirmed competent” embryos contained a lower level of PI+ EVs than the cut off level, suggesting that the competent embryo can indeed be identified by low PI+ EV counts. We developed a noninvasive, simple, inexpensive, quick test, which identifies the embryos that are most likely to implant. PMID:28057937

  13. Interfacial instability of turbulent two-phase stratified flow: Multi-equation turbulent modelling with rapid distortion

    CERN Document Server

    Náraigh, L Ó; Matar, O; Zaki, T

    2009-01-01

    We investigate the linear stability of a flat interface that separates a liquid layer from a fully-developed turbulent gas flow. In this context, linear-stability analysis involves the study of the dynamics of a small-amplitude wave on the interface, and we develop a model that describes wave-induced perturbation turbulent stresses (PTS). We demonstrate the effect of the PTS on the stability properties of the system in two cases: for a laminar thin film, and for deep-water waves. In the first case, we find that the PTS have little effect on the growth rate of the waves, although they do affect the structure of the perturbation velocities. In the second case, the PTS enhance the maximum growth rate, although the overall shape of the dispersion curve is unchanged. Again, the PTS modify the structure of the velocity field, especially at longer wavelengths. Finally, we demonstrate a kind of parameter tuning that enables the production of the thin-film (slow) waves in a deep-water setting.

  14. 六色荧光标记快速PCR扩增体系的建立及验证%Establishment and Verification of 6-color Fluorescent-labeled Rapid PCR Amplifi-cation System

    Institute of Scientific and Technical Information of China (English)

    刘亚举; 张俊涛; 金海英; 石美森

    2016-01-01

    Objective To establish the rapid PCR am plification program and system and to verify the technical indexes. Methods PCR m ultiplex and capillary electrophoresis detection of 24 autosom al STR loci and one Y-STR loci using the 6-color fluorescence m arking technology, as w ell as Amelogenin and Y-InDel. Meanw hile, sensitivity, specificity, identity, stability, m ixing and a batch of sam ple tests w ere investigated, and the genotype of various routine sam ples and degraded, exfoliated cell sam ples w ere observed. Results The sensitivity of the system w as 0.062 5 ng. In addition, the genotype could be detected accu-rately only around 65 m in via rapid am plification. The species-specificity w as high and the genotyping of all kinds of dry blood specim ens of filter paper and m ixed, degraded, exfoliated cell sam ples w ere accu-rate. Conclusion The rapid am plification system can significantly im prove the detection rate, and obtain accurate and stable genotyping results, w hich m ay be im portant im plications for the establishm ent of STR database and study on population genetics and forensic identification.%目的:建立PCR快速扩增程序和体系,并对其技术指标进行验证。方法采用六色荧光标记技术,对24个常染色体STR基因座、1个Y-STR基因座和Amelogenin、Y-InDel基因座进行复合扩增及毛细管电泳检测,同时考察体系的灵敏度、特异性、同一性、稳定性、混合样本及批量样本测试,并观察各种常见检材及降解、脱落细胞检材的分型情况。结果所建立的体系灵敏度达0.0625 ng,快速扩增仅耗时65 min就可获得准确分型;种属特异性高;各种纸质血样本和混合、降解、脱落细胞检材的分型正确。结论本研究建立的快速扩增体系可显著提升检验速率,分型准确、稳定,对建立STR数据库、研究群体遗传学和进行法医学鉴定有重要意义。

  15. Cliques, coloring, and satisfiability

    CERN Document Server

    Johnson, David S

    1996-01-01

    The purpose of a DIMACS Challenge is to encourage and coordinate research in the experimental analysis of algorithms. The First DIMACS Challenge encouraged experimental work in the area of network flow and matchings. The Second DIMACS Challenge, on which this volume is based, took place in conjunction with the DIMACS Special Year on Combinatorial Optimization. Addressed here are three difficult combinatorial optimization problems: finding cliques in a graph, coloring the vertices of a graph, and solving instances of the satisfiability problem. These problems were chosen both for their practical interest and because of their theoretical intractability.

  16. Rapid identification of Candida spp. frequently involved in invasive mycoses by using flow-through hybridization and Gene Chip (FHGC) technology.

    Science.gov (United States)

    Li, Chen; Ding, Xiurong; Liu, Zhizhong; Zhu, Juanjuan

    2017-01-01

    The incidence of invasive fungal infections in immunocompromised patients has increased in recent decades. Rapid and accurate identification of these pathogenic fungi is crucial for initiating a timely, safe, and effective antifungal therapy. Here we developed a microarray based on flow-through hybridization gene chip technology. The microarray was tested for its specificity using a panel of reference and blinded clinical isolates. The results proved that this microarray was highly discriminative, leading to the unequivocal identification of each species, including Candida famata and the highly related species Candida parapsilosis, Candida orthopsilosis, and Candida metapsilosis. This new system represents a reliable method that is of potential use in clinical laboratories for the simultaneous detection and identification of the most common pathogenic fungi. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Impact assessment of human diet changes with rapid urbanization on regional nitrogen and phosphorus flows--a case study of the megacity Shanghai.

    Science.gov (United States)

    Liu, Chen; Zou, Chunjing; Wang, Qinxue; Hayashi, Yoshitsugu; Yasunari, Tetsuzo

    2014-02-01

    Regional material flows are strongly influenced by human diets. To diagnose and prevent environmental problems that threaten urban sustainability, the impact of human diet changes with rapid urbanization on the regional nitrogen (N) and phosphorus (P) flows were quantitatively evaluated. A survey of day-to-day activities was conducted of 450 individuals surveyed (adults over 18 years old) in three representative areas (the central district, the new district, and the suburban/rural areas) of Shanghai, a megacity which has attracted worldwide attention. The lifestyle (eating habits, domestic sanitation, drainage facilities, etc.) pattern was determined and the potential N and P loads from human diets on the environment were calculated. The daily potential nitrogen and phosphorus loads from human diets was 19.36 g-N, 1.80 g-P in the central district, 16.48 g-N, 1.52 g-P in the new district, and 13.04 g-N, 1.20 g-P in the suburban/rural areas of Shanghai. Respondents in all three areas, especially those in the suburban/rural areas reported a preference for increasing the intake of animal-derived as well as processed foods, which means that the potential N and P load from human diets to the environment will increase further. In addition, most respondents consider industrial wastewater discharge as the main cause of eutrophication of waterbodies, though in recent years water pollution caused by domestic wastewater has increased rapidly, but this has received much less attention. Environment-friendly eating habits and improvements in the environmental awareness will be required.

  18. Development and evaluation of an up-converting phosphor technology-based lateral flow assay for rapid and quantitative detection of aflatoxin B1 in crops.

    Science.gov (United States)

    Zhao, Yong; Liu, Xiao; Wang, Xiaochen; Sun, Chongyun; Wang, Xinrui; Zhang, Pingping; Qiu, Jingfu; Yang, Ruifu; Zhou, Lei

    2016-12-01

    Contamination of grains and other crops by aflatoxin B1 (AFB1), a highly toxic aflatoxin produced by Aspergillus flavus and Aspergillus parasiticus, poses a serious threat to human health and is an important food safety issue. In this study, a competitive up-converting phosphor technology-based lateral flow (AFB1-UPT-LF) assay was developed for rapid detection of AFB1. Detection sensitivity of the proposed assay can reach 0.03ngmL(-1) for standard AFB1 solutions, with the coefficients of variation (CV) less than 10% (from 1.0 to 9.4%). A good linearity (r=0.9889) was observed for quantification of AFB1 from 0.03 to 1000ngmL(-1). Except for aflatoxin M1, no cross-reactivity was found with the abrin, ricin, ochratoxin A, botulinum toxin, shiga toxin 1, shiga toxin 2, and staphylococcal enterotoxin B, even at high concentrations of 100 or 1000ngmL(-)(1). After optimizing the extraction of AFB1, the assay showed good tolerance to various crop samples, with the detection limit (from 0.1 to 5ngg(-)(1)) lower than the corresponding maximum residue level (MRL) set in China. The AFB1-UPT-LF assay provides a promising tool for rapid on-site detection of AFB1 because of its high sensitivity, specificity, and sample tolerance. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Lateral flow test strip based on colloidal selenium immunoassay for rapid detection of melamine in milk, milk powder, and animal feed.

    Science.gov (United States)

    Wang, Zhizeng; Zhi, Dejuan; Zhao, Yang; Zhang, Hailong; Wang, Xin; Ru, Yi; Li, Hongyu

    2014-01-01

    Although high melamine (MEL) intake has been proven to cause serious health problems, MEL is sometimes illegally added to milk products and animal feed, arousing serious food safety concerns. A satisfactory method of detecting MEL in onsite or in-home testing is in urgent need of development. This work aimed to explore a rapid, convenient, and cost-effective method of identifying MEL in milk products or other food by colloidal selenium-based lateral flow immunoassay. Colloidal selenium was synthesized by L-ascorbic acid to reduce seleninic acid at room temperature. After conjugation with a monoclonal antibody anti-MEL, a test strip was successfully prepared. The detection limit of the test strip reached 150 μg/kg, 1,000 μg/kg, and 800 μg/kg in liquid milk, milk powder, and animal feed, respectively. No cross-reactions with homologues cyanuric acid, cyanurodiamide, or ammelide were found. Moreover, the MEL test strip can remain stable after storage for 1 year at room temperature. Our results demonstrate that the colloidal selenium MEL test strip can detect MEL in adulterated milk products or animal feed conveniently, rapidly, and sensitively. In contrast with a colloidal gold MEL test strip, the colloidal selenium MEL test strip was easy to prepare and more cost-efficient.

  20. Rapid and simple detection of Japanese encephalitis virus by reverse transcription loop-mediated isothermal amplification combined with a lateral flow dipstick.

    Science.gov (United States)

    Deng, Jieru; Pei, Jingjing; Gou, Hongchao; Ye, Zuodong; Liu, Cuicui; Chen, Jinding

    2015-03-01

    Japanese encephalitis virus (JEV) is a major cause of viral encephalitis in geographical areas, such as Asia and Western Pacific, where it is a threat to human and animal health. To control this disease, it is necessary to develop a rapid, simple, accurate method for diagnosis. In this study, a method based on reverse transcription loop-mediated isothermal amplification (RT-LAMP) coupled with a lateral flow dipstick (LFD) has been developed to detect JEV (JEV RT-LAMP-LFD). The entire assay can be completed within 70 min, and in this study, no false positive results were observed when other pathogens were tested, indicating that the assay is a highly specific method for the detection of JEV. Additionally, the sensitivity of the RT-LAMP-LFD assay for SA14-14-2 strain was 50 pg of RNA, which was similar to that of RT-PCR and RT-LAMP combined with gel electrophoresis, and was 10-fold more sensitive than RT-LAMP combined with calcein. The limit of detection for this assay was 5 pg of RNA. In addition, no false positive results were obtained with 14 serum samples. Our results indicate that this RT-LAMP-LFD assay will be of great value for JEV infection testing due to its rapid and highly specific and sensitive properties. Copyright © 2014 Elsevier B.V. All rights reserved.

  1. Development and Evaluation of a Rapid Antigen Detection and Serotyping Lateral Flow Antigen Detection System for Foot-and-Mouth Disease Virus.

    Directory of Open Access Journals (Sweden)

    Kazuki Morioka

    Full Text Available We developed a lateral flow strip using monoclonal antibodies (MAbs which allows for rapid antigen detection and serotyping of foot-and-mouth disease virus (FMDV. This FMDV serotyping strip was able to detect all 7 serotypes and distinguish serotypes O, A, C and Asia1. Its sensitivities ranged from 10(3 to 10(4 of a 50% tissue culture infectious dose of each FMDV stain; this is equal to those of the commercial product Svanodip (Boehringer Ingelheim Svanova, Uppsala, Sweden, which can detect all seven serotypes of FMDV, but does not distinguish them. Our evaluation of the FMDV serotyping strip using a total of 118 clinical samples (vesicular fluids, vesicular epithelial emulsions and oral and/or nasal swabs showed highly sensitive antigen detection and accuracy in serotyping in accordance with ELISA or RT-PCR. To the best of our knowledge, this is the first report on any FMDV serotyping strip that provides both rapid antigen detection and serotyping of FMDV at the same time on one strip without extra devices. This method will be useful in both FMD-free countries and FMD-infected countries, especially where laboratory diagnosis cannot be carried out.

  2. Development of a rapid lateral flow immunoassay test for detection of exosomes previously enriched from cell culture medium and body fluids

    Directory of Open Access Journals (Sweden)

    Myriam Oliveira-Rodríguez

    2016-08-01

    Full Text Available Exosomes are cell-secreted nanovesicles (40–200 nm that represent a rich source of novel biomarkers in the diagnosis and prognosis of certain diseases. Despite the increasingly recognized relevance of these vesicles as biomarkers, their detection has been limited due in part to current technical challenges in the rapid isolation and analysis of exosomes. The complexity of the development of analytical platforms relies on the heterogeneous composition of the exosome membrane. One of the most attractive tests is the inmunochromatographic strips, which allow rapid detection by unskilled operators. We have successfully developed a novel lateral flow immunoassay (LFIA for the detection of exosomes based on the use of tetraspanins as targets. We have applied this platform for the detection of exosomes purified from different sources: cell culture supernatants, human plasma and urine. As proof of concept, we explored the analytical potential of this LFIA platform to accurately quantify exosomes purified from a human metastatic melanoma cell line. The one-step assay can be completed in 15 min, with a limit of detection of 8.54×105 exosomes/µL when a blend of anti-CD9 and anti-CD81 were selected as capture antibodies and anti-CD63 labelled with gold nanoparticles as detection antibody. Based on our results, this platform could be well suited to be used as a rapid exosome quantification tool, with promising diagnostic applications, bearing in mind that the detection of exosomes from different sources may require adaptation of the analytical settings to their specific composition.

  3. CHO-S antibody titers >1 gram/liter using flow electroporation-mediated transient gene expression followed by rapid migration to high-yield stable cell lines.

    Science.gov (United States)

    Steger, Krista; Brady, James; Wang, Weili; Duskin, Meg; Donato, Karen; Peshwa, Madhusudan

    2015-04-01

    In recent years, researchers have turned to transient gene expression (TGE) as an alternative to CHO stable cell line generation for early-stage antibody development. Despite advances in transfection methods and culture optimization, the majority of CHO-based TGE systems produce insufficient antibody titers for extensive use within biotherapeutic development pipelines. Flow electroporation using the MaxCyte STX Scalable Transfection System is a highly efficient, scalable means of CHO-based TGE for gram-level production of antibodies without the need for specialized expression vectors or genetically engineered CHO cell lines. CHO cell flow electroporation is easily scaled from milligram to multigram quantities without protocol reoptimization while maintaining transfection performance and antibody productivity. In this article, data are presented that demonstrate the reproducibility, scalability, and antibody production capabilities of CHO-based TGE using the MaxCyte STX. Data show optimization of posttransfection parameters such as cell density, media composition, and feed strategy that result in secreted antibody titers >1 g/L and production of multiple grams of antibody within 2 weeks of a single CHO-S cell transfection. In addition, data are presented to demonstrate the application of scalable electroporation for the rapid generation of high-yield stable CHO cell lines to bridge the gap between early- and late-stage antibody development activities.

  4. Development of a Rapid Immunochromatographic Lateral Flow Device Capable of Differentiating Phytase Expressed from Recombinant Aspergillus niger phyA2 and Genetically Modified Corn.

    Science.gov (United States)

    Zhou, Xiaojin; Hui, Elizabeth; Yu, Xiao-Lin; Lin, Zhen; Pu, Ling-Kui; Tu, Zhiguan; Zhang, Jun; Liu, Qi; Zheng, Jian; Zhang, Juan

    2015-05-06

    Phytase is a phosphohydrolase considered highly specific for the degradation of phytate to release bound phosphorus for animal consumption and aid in the reduction of environmental nutrient loading. New sources of phytase have been sought that are economically and efficiently productive including the construction of genetically modified (GM) phytase products designed to bypass the costs associated with feed processing. Four monoclonal antibodies (EH10a, FA7, AF9a, and CC1) raised against recombinant Aspergillus niger phyA2 were used to develop a highly specific and sensitive immunochromatographic lateral flow device for rapid detection of transgenic phytase, such as in GM corn. Antibodies sequentially paired and tested along lateral flow strips showed that the EH10a-FA7 antibody pair was able to detect the recombinant yeast-phytase at 5 ng/mL, whereas the AF9a-CC1 antibody pair to GM phytase corn was able to detect at 2 ng/mL. Concurrent to this development, evidence was revealed which suggests that antibody binding sites may be glycosylated.

  5. A simple and rapid flow-injection chemiluminescence method for the determination of noscapine with Ru(phen)3(2+)-Ce(IV) system.

    Science.gov (United States)

    Rezaei, Behzad; Mokhtari, Ali; Khayamian, Taghi

    2007-08-01

    A new flow injection chemiluminescence (CL) system was used for the determination of noscapine. This technique is based on the reduction effect of noscapine on the Ru(phen)3(3+), which is produced by reaction between Ru(phen)3(2+) and acidic Ce(IV) solutions, and this rapid reduction produces strong CL. Calibration plots were linear over the range of 3.0 x 10(-7) - 2.0 x 10(-6) mol L(-1) and 2.0 x 10(-6) - 2.0 x 10(-4) mol L(-1). The CL intensity was so high, that it is able to produce a detection limit of 6.6 x 10(-8) M noscapine (3sigma). The relative standard deviation of 2.0 x 10(-6) M noscapine was 1.0% (n=10). The proposed method was successfully applied for the flow injection determination of noscapine in cough and Tonin syrup samples. The results of real sample analyses show good recovery percentages (97.3-102.4%). The minimum sampling rate was 100 samples per hour.

  6. A rapid and accurate method for determining protein content in dairy products based on asynchronous-injection alternating merging zone flow-injection spectrophotometry.

    Science.gov (United States)

    Liang, Qin-Qin; Li, Yong-Sheng

    2013-12-01

    An accurate and rapid method and a system to determine protein content using asynchronous-injection alternating merging zone flow-injection spectrophotometry based on reaction between coomassie brilliant blue G250 (CBBG) and protein was established. Main merit of our approach is that it can avoid interferences of other nitric-compounds in samples, such as melamine and urea. Optimized conditions are as follows: Concentrations of CBBG, polyvinyl alcohol (PVA), NaCl and HCl are 150 mg/l, 30 mg/l, 0.1 mol/l and 1.0% (v/v), respectively; volumes of the sample and reagent are 150 μl and 30 μl, respectively; length of a reaction coil is 200 cm; total flow rate is 2.65 ml/min. The linear range of the method is 0.5-15 mg/l (BSA), its detection limit is 0.05 mg/l, relative standard deviation is less than 1.87% (n=11), and analytical speed is 60 samples per hour.

  7. Rapid detection of BCR-ABL fusion genes using a novel combined LUX primer, in-cell RT-PCR and flow cytometric method.

    Science.gov (United States)

    Shi, Yan; Li, Li-Zhen; Sun, Jian-Zhi; Zhang, Ti; Peng, Jun; Xu, Cong-Gao

    2008-01-01

    Currently, quantitative and semiquantitative assays for minimal residual disease detection include fluorescence in situ hybridisation, multiparameter flow cytometric immunophenotyping and real-time quantitative polymerase chain reaction (RQ-PCR). We have developed a new approach to detect hybrid breakpoint cluster region and Abelson proto-oncogene (BCR-ABL) transcripts inside suspension cells using in situ RT-PCR and light upon extension (LUX) primer, followed by rapid quantitative analysis with flow cytometry. After cellular permeabilization and fixation of single cell suspension, the neoplastic mRNA was reverse transcribed and amplified by PCR with LUX primer. The results demonstrated that a strong positive yellow-green signal was observed in 99-100% cells of K562 cell line, only the red nucleus was detected in NB4 cell line and normal controls. The technique has been utilised to study 12 patients with chronic myeloid leukemia, and the results were compared with those of BCR-ABL fusion mRNA by RT-PCR and BCR-ABL fusion gene of the interphase cells by fluorescence in situ hybridization (FISH). In the five diagnosed patients, 90-98% cells were strongly positive. Four patients, including three patients treated with interferon-alpha and hydroxyurea and one patient treated with imatinib mesylate, had 26-82.5% positive cells. Three patients treated with imatinib mesylate were negative. The in situ RT-PCR results demonstrated complete concordance with the results of I-FISH and RT-PCR. A fluorescence signal was detectable at 1/10(4) cells and became negative below this threshold with flow cytometry. The results of the present study suggest that (1) LUX primers can be used to efficiently detect BCR-ABL fusion mRNA by in-cell RT-PCR; (2) the novel technique is a specific and sensitive way of detecting fusion gene with potential clinical usefulness.

  8. Modeling human color categorization

    NARCIS (Netherlands)

    van den Broek, Egon; Schouten, Th.E.; Kisters, P.M.F.

    2008-01-01

    A unique color space segmentation method is introduced. It is founded on features of human cognition, where 11 color categories are used in processing color. In two experiments, human subjects were asked to categorize color stimuli into these 11 color categories, which resulted in markers for a Colo

  9. Modeling human color categorization

    NARCIS (Netherlands)

    van den Broek, Egon; Schouten, Th.E.; Kisters, P.M.F.

    A unique color space segmentation method is introduced. It is founded on features of human cognition, where 11 color categories are used in processing color. In two experiments, human subjects were asked to categorize color stimuli into these 11 color categories, which resulted in markers for a

  10. Embedding Color Watermarks in Color Images

    Directory of Open Access Journals (Sweden)

    Wu Tung-Lin

    2003-01-01

    Full Text Available Robust watermarking with oblivious detection is essential to practical copyright protection of digital images. Effective exploitation of the characteristics of human visual perception to color stimuli helps to develop the watermarking scheme that fills the requirement. In this paper, an oblivious watermarking scheme that embeds color watermarks in color images is proposed. Through color gamut analysis and quantizer design, color watermarks are embedded by modifying quantization indices of color pixels without resulting in perceivable distortion. Only a small amount of information including the specification of color gamut, quantizer stepsize, and color tables is required to extract the watermark. Experimental results show that the proposed watermarking scheme is computationally simple and quite robust in face of various attacks such as cropping, low-pass filtering, white-noise addition, scaling, and JPEG compression with high compression ratios.

  11. Color vision and color formation in dragonflies.

    Science.gov (United States)

    Futahashi, Ryo

    2016-10-01

    Dragonflies including damselflies are colorful and large-eyed insects, which show remarkable sexual dimorphism, color transition, and color polymorphism. Recent comprehensive visual transcriptomics has unveiled an extraordinary diversity of opsin genes within the lineage of dragonflies. These opsin genes are differentially expressed between aquatic larvae and terrestrial adults, as well as between dorsal and ventral regions of adult compound eyes. Recent topics of color formation in dragonflies are also outlined. Non-iridescent blue color is caused by coherent light scattering from the quasiordered nanostructures, whereas iridescent color is produced by multilayer structures. Wrinkles or wax crystals sometimes enhances multilayer structural colors. Sex-specific and stage-specific color differences in red dragonflies is attributed to redox states of ommochrome pigments.

  12. Urine - abnormal color

    Science.gov (United States)

    ... medlineplus.gov/ency/article/003139.htm Urine - abnormal color To use the sharing features on this page, please enable JavaScript. The usual color of urine is straw-yellow. Abnormally colored urine ...

  13. Skin color - patchy

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003224.htm Skin color - patchy To use the sharing features on this page, please enable JavaScript. Patchy skin color is areas where the skin color is irregular. ...

  14. Spatial Accuracy of Embedded Surface Coloring in Color 3D Printing

    DEFF Research Database (Denmark)

    Pedersen, David Bue; Hansen, Hans Nørgaard; Eiríksson, Eyþór Rúnar

    2015-01-01

    Recent years, the industrial market for full-colorAM is growing rapidly. In the AM industry, most of the major technology providers are developingnew systems with improved color capabilities and with improved materials. In the last 12 months alone, 5 new technology platforms have been revealed ca...

  15. The effect of isometric exercise of the hand on the synovial blood flow in patients with rheumatoid arthritis measured by color Doppler ultrasound

    DEFF Research Database (Denmark)

    Ellegaard, Karen; Torp-Pedersen, Søren; Lund, Hans

    2013-01-01

    In 90% of patients with rheumatoid arthritis (RA), the joints of the hand are affected. Studies of grip strength training have not indicated a negative effect on disease activity after training. Introduction of ultrasound Doppler (USD) to measure increased blood flow induced by inflammation has...

  16. Digital color imaging

    CERN Document Server

    Fernandez-Maloigne, Christine; Macaire, Ludovic

    2013-01-01

    This collective work identifies the latest developments in the field of the automatic processing and analysis of digital color images.For researchers and students, it represents a critical state of the art on the scientific issues raised by the various steps constituting the chain of color image processing.It covers a wide range of topics related to computational color imaging, including color filtering and segmentation, color texture characterization, color invariant for object recognition, color and motion analysis, as well as color image and video indexing and retrieval. <

  17. Lateral flow test strip based on colloidal selenium immunoassay for rapid detection of melamine in milk, milk powder, and animal feed

    Directory of Open Access Journals (Sweden)

    Wang ZZ

    2014-04-01

    Full Text Available Zhizeng Wang,1 Dejuan Zhi,2 Yang Zhao,1 Hailong Zhang,2 Xin Wang,2 Yi Ru,1 Hongyu Li1,2 1MOE Key Laboratory of Cell Activities and Stress Adaptations, School of Life Sciences, Lanzhou University, Lanzhou, People's Republic of China; 2Institute of Microbiology and Biochemical Pharmacy, School of Pharmaceutics, Lanzhou University, Lanzhou, People's Republic of China Abstract: Although high melamine (MEL intake has been proven to cause serious health problems, MEL is sometimes illegally added to milk products and animal feed, arousing serious food safety concerns. A satisfactory method of detecting MEL in onsite or in-home testing is in urgent need of development. This work aimed to explore a rapid, convenient, and cost-effective method of identifying MEL in milk products or other food by colloidal selenium-based lateral flow immunoassay. Colloidal selenium was synthesized by L-ascorbic acid to reduce seleninic acid at room temperature. After conjugation with a monoclonal antibody anti-MEL, a test strip was successfully prepared. The detection limit of the test strip reached 150 µg/kg, 1,000 µg/kg, and 800 µg/kg in liquid milk, milk powder, and animal feed, respectively. No cross-reactions with homologues cyanuric acid, cyanurodiamide, or ammelide were found. Moreover, the MEL test strip can remain stable after storage for 1 year at room temperature. Our results demonstrate that the colloidal selenium MEL test strip can detect MEL in adulterated milk products or animal feed conveniently, rapidly, and sensitively. In contrast with a colloidal gold MEL test strip, the colloidal selenium MEL test strip was easy to prepare and more cost-efficient. Keywords: melamine, selenium nanoparticles, test strip, milk, animal feed, dairy food

  18. Rapid identification of ascomycetous yeasts from clinical specimens by a molecular method based on flow cytometry and comparison with identifications from phenotypic assays.

    Science.gov (United States)

    Page, Brent T; Shields, Christine E; Merz, William G; Kurtzman, Cletus P

    2006-09-01

    This study was designed to compare the identification of ascomycetous yeasts recovered from clinical specimens by using phenotypic assays (PA) and a molecular flow cytometric (FC) method. Large-subunit rRNA domains 1 and 2 (D1/D2) gene sequence analysis was also performed and served as the reference for correct strain identification. A panel of 88 clinical isolates was tested that included representatives of nine commonly encountered species and six infrequently encountered species. The PA included germ tube production, fermentation of seven carbohydrates, morphology on corn meal agar, urease and phenoloxidase activities, and carbohydrate assimilation tests when needed. The FC method (Luminex) employed species-specific oligonucleotides attached to polystyrene beads, which were hybridized with D1/D2 amplicons from the unidentified isolates. The PA identified 81 of 88 strains correctly but misidentified 4 of Candida dubliniensis, 1 of C. bovina, 1 of C. palmioleophila, and 1 of C. bracarensis. The FC method correctly identified 79 of 88 strains and did not misidentify any isolate but did not identify nine isolates because oligonucleotide probes were not available in the current library. The FC assay takes approximately 5 h, whereas the PA takes from 2 h to 5 days for identification. In conclusion, PA did well with the commonly encountered species, was not accurate for uncommon species, and takes significantly longer than the FC method. These data strongly support the potential of FC technology for rapid and accurate identification of medically important yeasts. With the introduction of new antifungals, rapid, accurate identification of pathogenic yeasts is more important than ever for guiding antifungal chemotherapy.

  19. Commercial lateral flow devices for rapid detection of peanut (Arachis hypogaea) and hazelnut (Corylus avellana) cross-contamination in the industrial production of cookies.

    Science.gov (United States)

    Röder, Martin; Vieths, Stefan; Holzhauser, Thomas

    2009-09-01

    Lateral flow devices (LFDs) are qualitative immunochromatographic tests for the rapid and specific detection of target analytes. We investigated commercially available LFDs for their ability to detect potentially allergenic peanut and hazelnut in raw cookie dough and chocolate, two important food matrices in the industrial production of cookies. Each three commercial LFDs for the detection of hazelnut and peanut were performed according to the manufacturers' instructions. All LFDs had comparably satisfactory specificity that was investigated with a variety of characteristic foods and food ingredients used in the production of cookies. In concordance with hazelnut-specific enzyme-linked immunosorbent assays (ELISAs), walnut was the most cross-reactive food for hazelnut-specific LFD. The sensitivity was verified in raw cookie doughs and chocolates that were either spiked with peanut or hazelnut between 1 and 25 mg/kg, respectively. Two hazelnut-specific LFDs detected hazelnut at a level of 3.5 mg/kg in both matrices, whereas the third LFD detected hazelnut at a level of 3.9 mg/kg in dough and 12.5 mg/kg in chocolate. Two peanut-specific LFDs detected peanut at a level of 1 mg/kg in both matrices. The third LFD detected peanut at a level of 14.2 mg/kg in chocolate and 4 mg/kg in dough. In conclusion, specific and sensitive LFD were identified for each hazelnut and peanut, having a level of sensitivity that is comparable to commercial ELISA for the investigated matrices. Such sensitive, specific, and rapid tests are useful analytical tools for allergen screening and sanitation in the industrial manufacture of foods.

  20. Colored Tensor Models - a Review

    Directory of Open Access Journals (Sweden)

    Razvan Gurau

    2012-04-01

    Full Text Available Colored tensor models have recently burst onto the scene as a promising conceptual and computational tool in the investigation of problems of random geometry in dimension three and higher. We present a snapshot of the cutting edge in this rapidly expanding research field. Colored tensor models have been shown to share many of the properties of their direct ancestor, matrix models, which encode a theory of fluctuating two-dimensional surfaces. These features include the possession of Feynman graphs encoding topological spaces, a 1/N expansion of graph amplitudes, embedded matrix models inside the tensor structure, a resumable leading order with critical behavior and a continuum large volume limit, Schwinger-Dyson equations satisfying a Lie algebra (akin to the Virasoro algebra in two dimensions, non-trivial classical solutions and so on. In this review, we give a detailed introduction of colored tensor models and pointers to current and future research directions.

  1. Rapid Quantitation of Ascorbic and Folic Acids in SRM 3280 Multivitamin/Multielement Tablets using Flow-Injection Tandem Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Bhandari, Deepak [ORNL; Kertesz, Vilmos [ORNL; Van Berkel, Gary J [ORNL

    2013-01-01

    RATIONALE: Ascorbic acid (AA) and folic acid (FA) are water-soluble vitamins and are usually fortified in food and dietary supplements. For the safety of human health, proper intake of these vitamins is recommended. Improvement in the analysis time required for the quantitative determination of these vitamins in food and nutritional formulations is desired. METHODS: A simple and fast (~5 min) in-tube sample preparation was performed, independently for FA and AA, by mixing extraction solvent with a powdered sample aliquot followed by agitation, centrifugation, and filtration to recover an extract for analysis. Quantitative detection was achieved by flow-injection (1 L injection volume) electrospray ionization tandem mass spectrometry (ESI-MS/MS) in negative ion mode using the method of standard addition. RESULTS: Method of standard addition was employed for the quantitative estimation of each vitamin in a sample extract. At least 2 spiked and 1 non-spiked sample extract were injected in triplicate for each quantitative analysis. Given an injection-to-injection interval of approximately 2 min, about 18 min was required to complete the quantitative estimation of each vitamin. The concentration values obtained for the respective vitamins in the standard reference material (SRM) 3280 using this approach were within the statistical range of the certified values provided in the NIST Certificate of Analysis. The estimated limit of detections of FA and AA were 13 and 5.9 ng/g, respectively. CONCLUSIONS: Flow-injection ESI-MS/MS was successfully applied for the rapid quantitation of FA and AA in SRM 3280 multivitamin/multielement tablets.

  2. The screening value in the first-trimester fetuses by color Doppler flow image%彩色多普勒超声应用于11~14周胎儿筛查的价值

    Institute of Scientific and Technical Information of China (English)

    王莉; 吴青青; 陈焰; 姚苓; 马玉庆; 杨文娟; 李晓菲

    2011-01-01

    Objective To examine the value of color Doppler flow image CDFI)in the screening of first-trimester fetus. Methods Two thousand and three hundred and eighty cases in first-trimester were screened by the color Doppler ultrasonography. Results A total of 2426 fetuses included 46 twins. Twenty-eight fetuses were abnormal including 8 cases of NT≥3. 0 mm and 11cases of NT≥3. 0 mm with the other abnormalities. Eight cases of abnormal anatomical structures included 1 case of multiplicitas, 1 case of cephalocele, 1 case of partial hydatidiform mole, 1 case of choroid plexus cysts ,4 case of central nerve system abnormalities( 3 cases of exencephaly ,1 case of anencephaly )and 1 case of reversal "A" wave in ductus venosus flow.Conclusion The Color Doppler ultrasonographic examination can provide the important hereditary information for prenatal screening of first-trimester fetus and screen fetal serious abnormal anatomical structures.%目的 探讨彩色多普勒超声用于11~14周胎儿筛查的价值.方法 应用彩色多普勒超声对2380例孕11~14周(胎儿头臀长在45~84 mm之间)的孕妇进行检查.结果 胎儿总数2426例,其中单胎2334例,双胎46例.共发现可疑异常胎儿28例:(1)颈项透明层(NT)≥3.0 mm 8例.(2)NT≥3.0 mm合并其他异常11例.(3)胎儿单纯解剖结构异常8例(1例多发畸形,1例脐膨出,1例胎盘部分性葡萄胎,1例脉络丛囊肿,4例中枢神经系统畸形包括露脑畸形3例、无脑儿1例).(4)静脉导管血流频谱异常1例.结论 彩色多普勒超声检查用于11~14周胎儿筛查能够提供重要的遗传学信息,发现严重的胎儿解剖结构异常.

  3. 彩色多普勒超声检查乳腺肿块20例分析%Analysis of 20 cases with breast disease examined by Color Doppler Flowing Imaging

    Institute of Scientific and Technical Information of China (English)

    黄冬梅; 邹成银

    2014-01-01

    Objective To analyze the clinical diagnosis value of Color Doppler Flowing Imaging in the diag-nosis of female breast mass ,discuss sonographic features of breast hyperplasia and maeexy dyeplesle .Methods The data of 20 patients with breast disease which diagnosed by Color Doppler Flowing Imaging were retrospectively ana -lyzed,some cases were conducted postoperative pathological examination .Results In all cases,13 cases were breast fibroadenoma(65.0%),6 cases were maeexy dyeplesle (30.0%),1 case was metaplastic squamous cell carcinoma (5.0%).The typical fibroadenoma had regular shape ,clear boundary and homogeneous internal echo ,and were mar-ginated smoothly with a fine echoic capsule and a lateral wall shadowing .Conclusion Color Doppler ultrasonography is an approach for noninvasive and simple examination of breast lesion ,and worthwhile for spreading in clinical prac-tice .Analysis of the ultrasonographic performance of breast fibroadenoma is helpful to the diagnosis and differential di -agnosis of breast disease ,which can also improve the level of diagnosis .%目的:分析乳腺纤维腺瘤与乳腺结构不良症的影像学特征,探讨彩色多普勒超声检查女性乳腺肿块的临床诊断价值。方法回顾性分析20例女性彩色多普勒超声检查资料,部分病例术后病理检查。结果20例患者中,乳腺纤维腺瘤13例(65.0%),乳腺结构不良症6例(30.0%),乳腺化生性癌1例(5.0%)。典型的乳腺纤维腺瘤声像学表现形态规则、境界清晰,内回声均质。结论彩色超声检查乳腺病变简便有效无创,值得临床广泛推广。分析乳腺纤维腺瘤的声像图表现,有助于乳腺病的诊断和鉴别诊断,提高诊断水平。

  4. Color Doppler Ultrasonographic Features of Hashimoto's Thyroiditis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Joo Hyuk; Kim, Mie Young; Rho, Eun Jin; Yi, Jeong Geun; Han, Chun Hwan [Kangnam General Hospital Public Corporation, Seoul (Korea, Republic of); Hwang, Hee Yong [Choong Ang Gil Hospital, Incheon (Korea, Republic of)

    1995-06-15

    Color Doppler ultrasonographic(US) features of 28 patients with Hashimato's thyroiditis were evaluated with regard to echo and color-flow patterns. Correlation of color-flow pattern with thyroid function was performed. All 28 patients showed varying degrees of diffuse enlargement of the thyroid gland and a heterogeneous echo pattern.Color-flow pattern of increased blood flow. Low to moderate, focally increased blood flow was seen in 26 patients(92.8%). Of these 26 patients, 24 patients showed subclinical hypothyroidism or euthyroidism. Two patients who showed hyperthyroidism showed several pieces of focally increased color flow, Which was noted during both systole and diastole. Diffuse, multifocal color-flow throughout thyroid gland was seen in two patients with Hashimato's thyroiditis: one with clinical hypothyroidism and the other with subclinical hypothyroidism. Even though Hashimoto's thyroiditis showed variable color-flow patterns, we believe that heterogenous parenchymal echopattern with low or moderately increased flow is a rather characteristic feature of Hashimoto's thyroiditis, and we suggest that color Doppler US provides additional information for evaluation of Hashimoto's thyroiditis

  5. Research on Displacement Flow of Internal Moisture in Porous Media During Rapid Drying Process%快速干燥过程中多孔介质内部

    Institute of Scientific and Technical Information of China (English)

    王馨; 王海; 施明恒; 虞维平

    2001-01-01

    提出了简化的弯通道模型.根据多孔物料的结构和干燥过程的特点,通过实验观测湿分在一定压力差作用下的迁移行为,着重研究快速干燥过程中多孔介质内部湿分的挤压流动现象.实验结果表明在一恒定温度下,当干燥物料两端的压力差逐渐增大时,湿分由物料内部到达外表面所需的时间逐渐减小且在相同的压力差降下,时间减小的幅度越来越小.在相同的压力差下,当液体温度升高时,湿分由物料内部到达外表面所需的时间随之减小.%In this paper, the authors put forward the idea that thedisplacement flow in capillary structure under pressure gradient is the main mechanism of high intense and rapid drying process. In this paper, both analytical and experimental studies are carried out to clarify the displacement process and its characteristic. A simplified displacement flow model is proposed and the time of the moisture migration is calculated. A one-dimentional displacement flow test device is built up and a set of experiments under different pressure gradients and temperatures are conducted. Glass beads of 0.8mm diameter are used as the porous material. The experiment results show that under a constant temperature, as the pressure gradient is getting greater, the time for moisture to reach the external surface from the internal is getting smaller and the range of time reducing is getting smaller too. On the other hand, under the same pressure gradient, as the liquid temperature increases, the time for moisture from the internal to the external surface decreases.

  6. A dual-color flow cytometry protocol for the simultaneous detection of Vibrio parahaemolyticus and Salmonella typhimurium using aptamer conjugated quantum dots as labels

    Energy Technology Data Exchange (ETDEWEB)

    Duan, Nuo; Wu, Shijia [State Key Laboratory of Food Science and Technology, School of Food Science and Technology, Jiangnan University, Wuxi 214122 (China); Yu, Ye [Zhangjiagang Entry-Exit Inspection and Quarantine Bureau, Zhangjiangang 215600 (China); Ma, Xiaoyuan; Xia, Yu; Chen, Xiujuan; Huang, Yukun [State Key Laboratory of Food Science and Technology, School of Food Science and Technology, Jiangnan University, Wuxi 214122 (China); Wang, Zhouping, E-mail: wangzp@jiangnan.edu.cn [State Key Laboratory of Food Science and Technology, School of Food Science and Technology, Jiangnan University, Wuxi 214122 (China)

    2013-12-04

    Graphical abstract: -- Highlights: •Two bacteria were simultaneously detected using QD-apt as labels by flow cytometry. •QD-apt were used for recognition and fluorescence detection of two bacteria. •The method was applied successfully for bacteria detection in real samples. -- Abstract: A sensitive, specific method for the collection and detection of pathogenic bacteria was demonstrated using quantum dots (QDs) as a fluorescence marker coupled with aptamers as the molecular recognition element by flow cytometry. The aptamer sequences were selected using a bacterium-based SELEX strategy in our laboratory for Vibrio parahaemolyticus and Salmonella typhimurium that, when applied in this method, allows for the specific recognition of the bacteria from complex mixtures including shrimp samples. Aptamer-modified QDs (QD-apt) were employed to selectively capture and simultaneously detect the target bacteria with high sensitivity using the fluorescence of the labeled QDs. The signal intensity is amplified due to the high photostability of QDs nanoparticles, resulting in improved sensitivity over methods using individual dye-labeled probes. This proposed method is promising for the sensitive detection of other pathogenic bacteria in food stuff if suitable aptamers are chosen. The method may also provide another potential platform for the application of aptamer-conjugated QDs in flow cytometry.

  7. A rapid dot immunoassay for detecting the Brazilian purpuric fever clone of Haemophilus influenzae biogroup aegyptius with a "flow through" device.

    Science.gov (United States)

    Ajello, G W; Matar, G M; Swaminathan, B; Bibb, W F; Helsel, L O; Perkins, B A

    1995-06-01

    Brazilian purpuric fever (BPF) is a highly fatal pediatric disease that may follow an episode of purulent conjunctivitis caused by a virulent clone of Haemophilus influenzae biogroup aegyptius (Hae). Oral rifampin prophylaxis, by eliminating carriage of the BPF clone in children with conjunctivitis, may prevent onset of the systemic disease. A test to detect the BPF clone directly from eye swabs could identify those in need of prophylaxis. This is a preliminary report of a rapid dot immunoassay performed on a "flow-through" cartridge that was developed for use under field conditions. The test is based upon recognition of a unique epitope of the 25-kDa pilin protein on the surface of BPF clone cells by a monoclonal antibody. With 36 laboratory-maintained cultures of Hae (15 clone isolates and 21 others), sensitivity of the assay was 67% and specificity was 95%. When fimbrial-enriched (25-kDa+) phenotypes of five false-negative clone strains were prepared for use as test antigens, sensitivity rose to 100%. Evaluation of the immunoassay under field conditions is necessary to prove its efficacy.

  8. Flow Cytometry for rapid characterization of colloidal particles of various types in process waters; Floedescytometri foer snabb karaktaerisering av kolloidala partiklar av olika typ i bakvatten - MPKT 05

    Energy Technology Data Exchange (ETDEWEB)

    Degerth, R.; Holmbom, B. [Aabo Akademi, Turku (Finland)

    1998-12-31

    Since more than ten years Flow Cytometry (FCM) has been used for characterization of blood cells and bacteria and has become indispensable for medical and biological use. FCM is able to count thousands of particles per second and simultaneously determine their the type and size ending up in a statistically significant report within less than a minute. The principle of FCM is based on a light excitation of a `lined up` particle stream and a multi-channel determination of scatter and fluorescence. This rapid technology has so far not been used in a greater extent within process industry, except for counting bacteria in milk and beer. BASF of Germany has developed and patented a single-channel fluorescence counter for determination of resin droplets in the process waters of paper making. The FCM, however, is a far more effective and reliable method, being able not only to detect resin droplets but also bacteria, live or dead, as well as other occurring particles. We know we are able to determine bacteria, we have seen resin and we aim to show that FCM is able to give a comprehensive view of the colloidal contents of process waters in paper mills by exploring means to selectively stain the different types of particles. (orig.) 3 refs. CACTUS Research Programme

  9. Development of a Novel Cocktail Enzyme-Linked Immunosorbent Assay and a Field-Applicable Lateral-Flow Rapid Test for Diagnosis of Contagious Bovine Pleuropneumonia.

    Science.gov (United States)

    Heller, Martin; Gicheru, Nimmo; Tjipura-Zaire, Georgina; Muriuki, Cecilia; Yu, Mingyan; Botelho, Ana; Naessens, Jan; Jores, Joerg; Liljander, Anne

    2016-06-01

    Contagious bovine pleuropneumonia (CBPP) is a severe respiratory disease that is widespread in sub-Saharan Africa. It is caused by Mycoplasma mycoides subsp. mycoides, a bacterium belonging to the Mycoplasma mycoides cluster. In the absence of an efficient CBPP vaccine, improved and easy-to-use diagnostic assays for recurrent testing combined with isolation and treatment of positive animals represent an option for CBPP control in Africa. Here we describe the comprehensive screening of 17 immunogenic Mycoplasma mycoides subsp. mycoides proteins using well-characterized bovine sera for the development of a novel cocktail enzyme-linked immunosorbent assay (ELISA) for laboratory use. Two recombinant Mycoplasma immunogens, MSC_0136 and MSC_0636, were used to set up a standardized cocktail ELISA protocol. According to the results from more than 100 serum samples tested, the sensitivity and specificity of the novel cocktail ELISA were 85.6% and 96.4%, respectively, with an overall diagnostic accuracy comparable to that of the Office International des Epizooties (OIE)-prescribed serological assays. In addition, we provide a proof of principle for a field-applicable, easy-to-use commercially produced prototype lateral-flow test for rapid (<30-min) diagnosis of CBPP.

  10. Simple and rapid determination of thiabendazole, imazalil, and o-phenylphenol in citrus fruit using flow-injection electrospray ionization tandem mass spectrometry.

    Science.gov (United States)

    Ito, Yuko; Goto, Tomomi; Oka, Hisao; Matsumoto, Hiroshi; Miyazaki, Yutaka; Takahashi, Nobuyuki; Nakazawa, Hiroyuki

    2003-02-12

    A simple and rapid analytical method for thiabendazole (TBZ), imazalil (IMA), and o-phenylphenol (OPP) in citrus fruit has been developed by using flow-injection electrospray ionization tandem mass spectrometry for the first time. The method involves the combined use of stable isotopically labeled internal standards (thiabendazole-(13)C(6), imazalil-d(5), and p-phenylphenol-d(9)) and a multiple reaction monitoring technique. The average recoveries for the fungicides at the tolerance levels (TBZ and OPP, 10 mg/kg; IMA, 5 mg/kg) ranged from 77 to 101%, with the coefficients of variation (CVs) ranging from 0.7 to 4.2% (n = 5). At half the tolerance levels (TBZ and OPP, 5 mg/kg; IMA, 2.5 mg/kg), the average recoveries ranged from 62 to 112%, with the CVs ranging from 0.7 to 8.4% (n = 5). The CVs of the average recoveries, obtained from lemon samples fortified with three fungicides at the tolerance levels, obtained on three different days over two weeks, ranged within 2%. The analysis time, including sample preparation and determination, is only 15 min.

  11. Rapid determination of zinc and iron in foods by flow-injection analysis with flame atomic-absorption spectrophotometry and slurry nebulization.

    Science.gov (United States)

    de Andrade, J C; Strong, F C; Martin, N J

    1990-07-01

    A rapid method of determining zinc and iron in food by flame atomic-absorption spectrophotometry with slurry nebulization into an air-acetylene flame has been developed. A V-groove, clog-free Babington-type nebulizer, coupled to a single-line flow-injection analysis (FIA) system, was employed to introduce the slurry into the spray chamber. Under the FIA conditions described, an injection frequency of 120/hr is possible, with negligible carry-over and memory effects. The calibration graphs were obtained by using various concentrations (up to 0.1 g/ml) of white bean homogenate as standards, rather than solutions. The method has been applied to various kinds of foods, including grains, vegetables, fruits and sausage. Homogenization of semi-prepared samples to form slurries took only 4 min. Relative deviations between results by the slurry and solution methods for both elements averaged 2-3%. Detection limits by the slurry method were 0.3 mug/ml Zn and 0.6 mug/ml Fe.

  12. Texture affects color emotion

    NARCIS (Netherlands)

    Lucassen, M.P.; Gevers, T.; Gijsenij, A.

    2011-01-01

    Several studies have recorded color emotions in subjects viewing uniform color (UC) samples. We conduct an experiment to measure and model how these color emotions change when texture is added to the color samples. Using a computer monitor, our subjects arrange samples along four scales: warm-cool,

  13. Texture affects color emotion

    NARCIS (Netherlands)

    Lucassen, M.P.; Gevers, T.; Gijsenij, A.

    2011-01-01

    Several studies have recorded color emotions in subjects viewing uniform color (UC) samples. We conduct an experiment to measure and model how these color emotions change when texture is added to the color samples. Using a computer monitor, our subjects arrange samples along four scales: warm-cool,

  14. Elliptic flow of electrons from heavy-flavour hadron decays at mid-rapidity in Pb-Pb collisions at root s(NN)=2.76 TeV

    NARCIS (Netherlands)

    Adam, J.; Adamova, D.; Aggarwal, M. M.; Rinella, G. Aglieri; Agnello, M.; Agrawal, N.; Ahammed, Z.; Ahn, S. U.; Aiola, S.; Akindinov, A.; Alam, S. N.; Albuquerque, D. S. D.; Aleksandrov, D.; Alessandro, B.; Alexandre, D.; Alfaro Molina, R.; Alici, A.; Alkin, A.; Alme, J.; Alt, T.; Altinpinar, S.; Altsybeev, I.; Alves Garcia Prado, C.; Andrei, C.; Andronic, A.; Anguelov, V.; Anticic, T.; Antinori, F.; Antonioli, P.; Aphecetche, L.; Appelshaeuser, H.; Arcelli, S.; Arnaldi, R.; Arnold, O. W.; Arsene, I. C.; Arslandok, M.; Audurier, B.; Augustinus, A.; Averbeck, R.; Azmi, M. D.; Badala, A.; Baek, Y. W.; Bagnasco, S.; Bailhache, R.; Bala, R.; Balasubramanian, S.; Baldisseri, A.; Baral, R. C.; Barbano, A. M.; Barbera, R.; Barile, F.; Barnafoldi, G. G.; Barnby, L. S.; Barret, V.; Bartalini, P.; Barth, K.; Bartke, J.; Bartsch, E.; Basile, M.; Bastid, N.; Bathen, B.; Batigne, G.; Camejo, A. Batista; Batyunya, B.; Batzing, P. C.; Bearden, I. G.; Beck, H.; Bedda, C.; Behera, N. K.; Belikov, I.; Bellini, F.; Bello Martinez, H.; Bellwied, R.; Belmont, R.; Belmont-Moreno, E.; Beltran, L. G. E.; Belyaev, V.; Bencedi, G.; Beole, S.; Berceanu, I.; Bercuci, A.; Berdnikov, Y.; Berenyi, D.; Bertens, R. A.; Berzano, D.; Betev, L.; Bhasin, A.; Bhat, I. R.; Bhati, A. K.; Bhattacharjee, B.; Bhom, J.; Bianchi, L.; Bianchi, N.; Bianchin, C.; Bielcik, J.; Bielcikova, J.; Bilandzic, A.; Biro, G.; Biswas, R.; Biswas, S.; Bjelogrlic, S.; Blair, J. T.; Blau, D.; Blume, C.; Bock, F.; Bogdanov, A.; Boggild, H.; Boldizsar, L.; Bombara, M.; Bonora, M.; Book, J.; Borel, H.; Borissov, A.; Borri, M.; Bossu, F.; Botta, E.; Bourjau, C.; Braun-Munzinger, P.; Bregant, M.; Breitner, T.; Broker, T. A.; Browning, T. A.; Broz, M.; Brucken, E. J.; Bruna, E.; Bruno, G. E.; Budnikov, D.; Buesching, H.; Bufalino, S.; Buncic, P.; Busch, O.; Buthelezi, Z.; Butt, J. B.; Buxton, J. T.; Cabala, J.; Caffarri, D.; Cai, X.; Caines, H.; Diaz, L. Calero; Caliva, A.; Calvo Villar, E.; Camerini, P.; Carena, F.; Carena, W.; Carnesecchi, F.; Castellanos, J. Castillo; Castro, A. J.; Casula, E. A. R.; Ceballos Sanchez, C.; Cepila, J.; Cerello, P.; Cerkala, J.; Chang, B.; Chapeland, S.; Chartier, M.; Charvet, J. L.; Chattopadhyay, S.; Chattopadhyay, S.; Chauvin, A.; Chelnokov, V.; Cherney, M.; Cheshkov, C.; Cheynis, B.; Barroso, V. Chibante; Chinellato, D. D.; Cho, S.; Chochula, P.; Choi, K.; Chojnacki, M.; Choudhury, S.; Christakoglou, P.; Christensen, C. H.; Christiansen, P.; Chujo, T.; Cicalo, C.; Cifarelli, L.; Cindolo, F.; Cleymans, J.; Colamaria, F.; Colella, D.; Collu, A.; Colocci, M.; Balbastre, G. Conesa; del Valle, Z. Conesa; Connors, M. E.; Contreras, J. G.; Cormier, T. M.; Morales, Y. Corrales; Cortes Maldonado, I.; Cortese, P.; Cosentino, M. R.; Costa, F.; Crkovska, J.; Crochet, P.; Cruz Albino, R.; Cuautle, E.; Cunqueiro, L.; Dahms, T.; Dainese, A.; Danisch, M. C.; Danu, A.; Das, I.; Das, S.; Dash, A.; Dash, S.; De, S.; De Caro, A.; de Cataldo, G.; de Conti, C.; de Cuveland, J.; De Falco, A.; De Gruttola, D.; De Marco, N.; De Pasquale, S.; De Souza, R. D.; Deisting, A.; Deloff, A.; Denes, E.; Deplano, C.; Dhankher, P.; Di Bari, D.; Di Mauro, A.; Di Nezza, P.; Di Ruzza, B.; Diaz Corchero, M. A.; Dietel, T.; Dillenseger, P.; Divia, R.; Djuvsland, O.; Dobrin, A.; Domenicis Gimenez, D.; Doenigus, B.; Dordic, O.; Drozhzhova, T.; Dubey, A. K.; Dubla, A.; Ducroux, L.; Dupieux, P.; Ehlers, R. J.; Elia, D.; Endress, E.; Engel, H.; Epple, E.; Erazmus, B.; Erdemir, I.; Erhardt, F.; Espagnon, B.; Estienne, M.; Esumi, S.; Eum, J.; Evans, D.; Evdokimov, S.; Eyyubova, G.; Fabbietti, L.; Fabris, D.; Faivre, J.; Fantoni, A.; Fasel, M.; Feldkamp, L.; Feliciello, A.; Feofilov, G.; Ferencei, J.; Fernandez Tellez, A.; Ferreiro, E. G.; Ferretti, A.; Festanti, A.; Feuillard, V. J. G.; Figiel, J.; Figueredo, M. A. S.; Filchagin, S.; Finogeev, D.; Fionda, F. M.; Fiore, E. M.; Fleck, M. G.; Floris, M.; Foertsch, S.; Foka, P.; Fokin, S.; Fragiacomo, E.; Francescon, A.; Francisco, A.; Frankenfeld, U.; Fronze, G. G.; Fuchs, U.; Furget, C.; Furs, A.; Girard, M. Fusco; Gaardhoje, J. J.; Gagliardi, M.; Gago, A. M.; Gajdosova, K.; Gallio, M.; Galvan, C. D.; Gangadharan, D. R.; Ganoti, P.; Gao, C.; Garabatos, C.; Garcia-Solis, E.; Gargiulo, C.; Gasik, P.; Gauger, E. F.; Germain, M.; Gheata, M.; Gianotti, P.; Giubellino, P.; Giubilato, P.; Gladysz-Dziadus, E.; Glaessel, P.; Gomez Coral, D. M.; Ramirez, A. Gomez; Gonzalez, A. S.; Gonzalez, V.; Gonzalez-Zamora, P.; Gorbunov, S.; Gorlich, L.; Gotovac, S.; Grabski, V.; Grachov, O. A.; Graczykowski, L. K.; Graham, K. L.; Grelli, A.; Grigoras, A.; Grigoras, C.; Grigoriev, V.; Grigoryan, A.; Grigoryan, S.; Grinyov, B.; Grion, N.; Gronefeld, J. M.; Grosse-Oetringhaus, J. F.; Grosso, R.; Gruber, L.; Guber, F.

    2016-01-01

    The elliptic flow of electrons from heavy-flavour hadron decays at mid-rapidity (|y| <0.7) is measured in Pb-Pb collisions at TeV with ALICE at the LHC. The particle azimuthal distribution with respect to the reaction plane can be parametrized with a Fourier expansion, where the second coefficient

  15. Sensory Drive, Color, and Color Vision.

    Science.gov (United States)

    Price, Trevor D

    2017-08-01

    Colors often appear to differ in arbitrary ways among related species. However, a fraction of color diversity may be explained because some signals are more easily perceived in one environment rather than another. Models show that not only signals but also the perception of signals should regularly evolve in response to different environments, whether these primarily involve detection of conspecifics or detection of predators and prey. Thus, a deeper understanding of how perception of color correlates with environmental attributes should help generate more predictive models of color divergence. Here, I briefly review our understanding of color vision in vertebrates. Then I focus on opsin spectral tuning and opsin expression, two traits involved in color perception that have become amenable to study. I ask how opsin tuning is correlated with ecological differences, notably the light environment, and how this potentially affects perception of conspecific colors. Although opsin tuning appears to evolve slowly, opsin expression levels are more evolutionarily labile but have been difficult to connect to color perception. The challenge going forward will be to identify how physiological differences involved in color vision, such as opsin expression levels, translate into perceptual differences, the selection pressures that have driven those differences, and ultimately how this may drive evolution of conspecific colors.

  16. Industrial Color Physics

    CERN Document Server

    Klein, Georg A

    2010-01-01

    This unique book starts with a short historical overview of the development of the theories of color vision and applications of industrial color physics. The three dominant factors producing color - light source, color sample, and observer - are described in detail. The standardized color spaces are shown and related color values are applied to characteristic color qualities of absorption as well as of effect colorants. The fundamentals of spectrometric and colorimetric measuring techniques together with specific applications are described. Theoretical models for radiative transfer in transparent, translucent, and opaque layers are detailed; the two, three, and multi-flux approximations are presented for the first time in a coherent formalism. These methods constitute the fundamentals not only for the important classical methods, but also modern methods of recipe prediction applicable to all known colorants. The text is supplied with 52 tables, more than 200 partially colored illustrations, an appendix, and a...

  17. Population genomics of divergence among extreme and intermediate color forms in a polymorphic insect.

    Science.gov (United States)

    Lozier, Jeffrey D; Jackson, Jason M; Dillon, Michael E; Strange, James P

    2016-02-01

    Geographic variation in insect coloration is among the most intriguing examples of rapid phenotypic evolution and provides opportunities to study mechanisms of phenotypic change and diversification in closely related lineages. The bumble bee Bombus bifarius comprises two geographically disparate color groups characterized by red-banded and black-banded abdominal pigmentation, but with a range of spatially and phenotypically intermediate populations across western North America. Microsatellite analyses have revealed that B. bifarius in the USA are structured into two major groups concordant with geography and color pattern, but also suggest ongoing gene flow among regional populations. In this study, we better resolve the relationships among major color groups to better understand evolutionary mechanisms promoting and maintaining such polymorphism. We analyze >90,000 and >25,000 single-nucleotide polymorphisms derived from transcriptome (RNAseq) and double digest restriction site associated DNA sequencing (ddRAD), respectively, in representative samples from spatial and color pattern extremes in B. bifarius as well as phenotypic and geographic intermediates. Both ddRAD and RNAseq data illustrate substantial genome-wide differentiation of the red-banded (eastern) color form from both black-banded (western) and intermediate (central) phenotypes and negligible differentiation among the latter populations, with no obvious admixture among bees from the two major lineages. Results thus indicate much stronger background differentiation among B. bifarius lineages than expected, highlighting potential challenges for revealing loci underlying color polymorphism from population genetic data alone. These findings will have significance for resolving taxonomic confusion in this species and in future efforts to investigate color-pattern evolution in B. bifarius and other polymorphic bumble bee species.

  18. [Development and comparative evaluation of up-converting phosphor technology based lateral flow assay for rapid detection of Yersinia pestis, Bacillus anthracis spore and Brucella spp].

    Science.gov (United States)

    Li, Chunfeng; Zhang, Pingping; Wang, Xiaoying; Liu, Xiao; Zhao, Yong; Sun, Chongyun; Wang, Chengbin; Yang, Ruifu; Zhou, Lei

    2015-01-01

    To develop an up-converting phosphor technology based lateral flow (UPT-LF) assay for rapid and quantitative detection of Yersinia pestis, Bacillus anthracis spore and Brucella spp.and make the comparison with BioThreat Alert (BTA) test strips (Tetracore Inc., USA). Using up-converting phosphor nano-particles (UCP-NPs) as the bio-marker, three double-antibody-sandwich model based UPT-LF strips including Plague-UPT-LF, Anthrax-UPT-LF, Brucella-UPT-LF were prepared and its sensitivity, accuracy, linearity and specificity were determined by detecting 10(10), 10(9), 10(8), 10(7), 10(6), 10(5) and 0 CFU/ml series of concentrations of Y.pestis, B.anthracis, Brucella standards and other 27 kinds of 10(9) CFU/ml series of contrations of bacteria strains.Furthermore, the speed, sensitivity and accuracy of bacteria standards and simulated sample detection were compared between UPT-LF and BTA system. The detection limit of Plague-UPT-LF, Anthrax-UPT-LF and Brucella-LF was 10(5) CFU/ml. The CV of series of bacteria concentrations was ≤ 15%, and the r between lg (T/C-cut-off) and lg (concentration) was 0.996,0.998 and 0.999 (F values were 1 647.57, 743.51 and 1 822.17. All the P values were Brucella-LF were excellent, while that of Anthrax-UPT-LF was a little bit regretful because of non-specific reaction with two isolates of B. subtilis and one B.cereus. On-site evaluation showed the detection time of UPT-LF for all Y.pestis, B.anthracis spore and Brucella spp.was 33, 36 and 37 min, while BTA was 115, 115 and 111 min, which revealed the higher detection speed and sensitivity of UPT-LF comparing with BTA. The negative rate of two methods for blank standard was both 5/5, the sensitivity of UPT-LF for Y.pestis,B.anthracis spore and Brucella spp. was all 10(5) CFU/ml, then BTA was 10(6), 10(6) and 10(5) CFU/ml, respectively. The detection rate of UPT-LF for all three bacteria analog positive samples was 16/16, while BTA for B.anthracis was 7/16 only. The good performance

  19. Mechanochromic Fibers with Structural Color.

    Science.gov (United States)

    Li, Houpu; Sun, Xuemei; Peng, Huisheng

    2015-12-21

    Responsive photonic crystals have been widely developed to realize tunable structural colors by manipulating the flow of light. Among them, mechanochromic photonic crystals attract increasing attention due to the easy operation, high safety and broad applications. Recently, mechanochromic photonic crystal fibers were proposed to satisfy the booming wearable smart textile market. In this Concept, the fundamental mechanism, fabrication, and recent progress on mechanochromic photonic crystals, especially in fiber shape, are summarized to represent a new direction in sensing and displaying.

  20. Color doppler blood flow imaging in twin reversed arterial perfusion sequence%彩色多普勒超声诊断双胎反向动脉灌注序列征

    Institute of Scientific and Technical Information of China (English)

    李雪蕾; 李昌安; 穆仲平

    2012-01-01

    目的探讨彩色多普勒超声诊断双胎反向动脉灌注序列征的价值.方法对5例双胎反向动脉灌注序列征的产前彩色多普勒超声检查结果进行回顾性分析,并与产后结果对照,总结声像图表现及诊断要点.结果 5例于产前彩色多普勒超声检查中发现并于产后证实为双胎反向动脉灌注序列征;5例均为单绒毛膜双胎,其中3例为单羊膜囊,2例为双羊膜囊;5例均为无脑、无心畸胎.结论彩色多普勒超声检查可以准确并及早诊断双胎反向动脉灌注序列征,有助于指导临床实现优生优育.%Objective To detect the diagnostic value of color doppler blood flow imaging in twin reversed arterial perfusion sequence. Methods Review and analysis of 5 cases of twin reversed arterial perfusion sequence were examined by color Doppler, and compared with the results of the clinical diagnosis after delivery. The main points of diagnosis were summarized. Results The twin reversed arterial perfusion sequence was observed in prenatal examination and demonstrated in postpartum through prenatal ultrasonic inspection system of 5 inspection objects. All 5 cases were confirmed to monochorionic twin. Among them 3 cases were monoamnionic twin and 2 cases were diamnionic twin. All 5 cases were anencephalia and acardia. Conclusion Color doppler imaging can provide accurate diagnoses with twin reversed arterial perfusion sequence timely, and will offer available instructions on clinical therapy to achieve prenatal and postnatal care.

  1. Associations between abnormal ultrasound color Doppler measures and tendon pain symptoms in badminton players during a season

    DEFF Research Database (Denmark)

    Boesen, Anders Ploug; Boesen, Morten Ilum; Torp-Pedersen, Soren

    2012-01-01

    Color Doppler ultrasound is widely used to examine intratendinous flow in individuals with overuse tendon problems, but the association between color Doppler and pain is still unclear.......Color Doppler ultrasound is widely used to examine intratendinous flow in individuals with overuse tendon problems, but the association between color Doppler and pain is still unclear....

  2. Color-Stripe Structured Light Robust to Surface Color and Discontinuity

    CERN Document Server

    Lee, Kwang Hee; Lee, Sang Wook

    2015-01-01

    Multiple color stripes have been employed for structured light-based rapid range imaging to increase the number of uniquely identifiable stripes. The use of multiple color stripes poses two problems: (1) object surface color may disturb the stripe color and (2) the number of adjacent stripes required for identifying a stripe may not be maintained near surface discontinuities such as occluding boundaries. In this paper, we present methods to alleviate those problems. Log-gradient filters are employed to reduce the influence of object colors, and color stripes in two and three directions are used to increase the chance of identifying correct stripes near surface discontinuities. Experimental results demonstrate the effectiveness of our methods.

  3. Clinical evaluation of leukocyte differential count in peripheral blood by five-color flow cytometry%五色流式细胞术分类计数外周血白细胞的临床评价

    Institute of Scientific and Technical Information of China (English)

    邢莹; 王建中; 普程伟; 尚柯

    2013-01-01

    目的 评价五色流式细胞术分类计数外周血白细胞的临床应用价值.方法 选取2010年9至12月北京大学第一医院就诊的265例患者静脉全血标本,以显微镜检查为参考方法,同时用LH750全自动血细胞分析仪和FC500流式细胞仪分类计数白细胞,统计分析显微镜、血细胞分析仪和流式细胞术分类计数外周血白细胞的相关性.选取2010年8至11月北京大学第一医院、北京市道培医院和北京军区总医院的40例患者的静脉全血标本,以显微镜检查为参考方法,同时用LH750全自动血细胞分析仪和NAVIOS流式细胞仪分类计数白细胞,统计分析显微镜、血细胞分析仪和流式细胞术分类计数外周血白细胞的相关性和流式细胞术的临床诊断效率.结果 FC500流式细胞仪采用仪器自动分析软件进行分类,与显微镜分类计数5种白细胞均具有一定相关性(均P<0.01),其中以淋巴细胞、中性粒细胞和嗜酸粒细胞的相关性最佳(r=0.955、0.928、0.876).NAVIOS 流式细胞仪采用手工输入设门策略进行分类,与显微镜方法比较除嗜碱粒细胞外均具有良好的相关性(r >0.700,均P<0.01),其中对检出中性粒细胞、淋巴细胞和原始细胞的相关性较高(r=0.950、0.915、0.852).以显微镜法分类计数外周血不成熟粒细胞1%为临界值,流式细胞术检出不成熟粒细胞的敏感度为87%,特异度为76%.以显微镜法检查外周血原始细胞0.5%为临界值,流式细胞术检出的敏感度为100%,特异度为92%.结论 应用五色流式细胞术在不同流式细胞仪上分类计数外周血白细胞与显微镜法均具有良好的相关性,对检出原始细胞和不成熟粒细胞具有较高的敏感度.%Objective To explore the clinical application values of five-color flow cytometry for leukocyte differential count in peripheral blood.Methods Leukocyte differentiation in 265 peripheral blood samples collected at

  4. Evaluation of up-converting phosphor technology-based lateral flow strips for rapid detection of Bacillus anthracis Spore, Brucella spp., and Yersinia pestis.

    Directory of Open Access Journals (Sweden)

    Pingping Zhang

    Full Text Available Bacillus anthracis, Brucella spp., and Yersinia pestis are zoonotic pathogens and biowarfare- or bioterrorism-associated agents that must be detected rapidly on-site from various samples (e.g., viscera and powders. An up-converting phosphor technology-based lateral flow (UPT-LF strip was developed as a point-of-care testing (POCT to satisfy the requirements of first-level emergency response. We developed UPT-LF POCT to quantitatively detect the three pathogens within 15 min. Sample and operation-error tolerances of the assay were comprehensively evaluated. The sensitivity of UPT-LF assay to bacterial detection reached 10(4 cfu · mL(-1 (100 cfu/test, with a linear quantitative range of 4 to 6 orders of magnitude. Results revealed that the UPT-LF assay exhibited a high specificity with the absence of false-positive results even at 10(9 cfu · mL(-1 of non-specific bacterial contamination. The assay could tolerate samples with a wide pH range (2 to 12, high ion strengths (≥ 4 mol · L(-1 of NaCl, high viscosities (≤ 25 mg · mL(-1 of PEG20000 or ≥ 20% of glycerol, and high concentrations of bio-macromolecule (≤ 200 mg · mL(-1 of bovine serum albumin or ≥ 80 mg · mL(-1 of casein. The influence of various types of powders and viscera (fresh and decomposed on the performance of UPT-LF assay was determined. The operational error of liquid measurement exhibited few effects on sensitivity and specificity. The developed UPT-LF POCT assay is applicable under field conditions with excellent tolerance to sample complexity and operational error.

  5. Validation of a rapid lateral flow test for the simultaneous determination of β-lactam drugs and flunixin in raw milk.

    Science.gov (United States)

    Douglas, David; Banaszewski, Katie; Juskelis, Rima; Al-Taher, Fadwa; Chen, Yang; Cappozzo, Jack; McRobbie, Lindsay; Salter, Robert S

    2012-07-01

    β-Lactam antibiotics are the most commonly used drugs on dairy farms. β-Lactam residues in milk are kept out of the human milk supply with good agricultural practices and mandatory truck screening performed by the dairy industry under Appendix N of the Pasteurized Milk Ordinance. Flunixin, a nonsteroidal and anti-inflammatory drug, appears in dairy cattle tissue residues with a frequency similar to the occurrence of penicillin G. This creates concern that flunixin residues could be in milk and would go undetected under current milk screening programs. A single test that combines mandatory β-lactam screening with voluntary flunixin screening is an economical approach for monitoring and controlling for potential flunixin or 5-hydroxyflunixin, the primary flunixin metabolite marker in milk. The objective of this study was to validate a β-lactam and flunixin rapid lateral flow test (LFT) and compare the results obtained with a liquid chromatography-triple quadrupole tandem mass spectrometry (LC-MS/MS) method for the simultaneous determination of flunixin and 5-hydroxyflunixin in raw milk with a limit of detection of , 1 ppb, equivalent to 1 ng/ml. Using the LFT, three combined manufactured lots of test strips detected penicillin G at 2.0 ppb, ampicillin at 6.8 ppb, amoxicillin at 5.9 ppb, cephapirin at 13.4 ppb, ceftiofur (total metabolites) at 63 ppb, and 5-hydroxyflunixin at 1.9 ppb at least 90% of the time with 95% confidence. The LFT also detected incurred flunixin milk samples that were analyzed with the LC-MS/MS and diluted to tolerance in raw milk. The detection levels for the LFT are lower than the U.S. safe levels or tolerances and qualify the test to be used in compliance with U.S. milk screening programs.

  6. Food colors: Existing and emerging food safety concerns.

    Science.gov (United States)

    Oplatowska-Stachowiak, Michalina; Elliott, Christopher T

    2017-02-11

    Food colors are added to different types of commodities to increase their visual attractiveness or to compensate for natural color variations. The use of these additives is strictly regulated in the European Union, the United States, and many other countries worldwide. There is a growing concern about the safety of some commonly used legal food colorants and there is a trend to replace the synthetic forms with natural products. Additionally, a number of dyes with known or suspected genotoxic or carcinogenic properties have been shown to be added illegally to foods. Robust monitoring programs based on reliable detection methods are required to assure the food is free from harmful colors. The aim of this review is to present an up to date status of the various concerns arising from use of color additives in food. The most important food safety concerns in the field of food colors are lack of uniform regulation concerning legal food colors worldwide, possible link of artificial colors to hyperactive behavior, replacement of synthetic colors with natural ones, and the presence of harmful illegal dyes-both known but also new, emerging ones in food. The legal status of food color additives in the EU, United States, and worldwide is summarized. The reported negative health effects of both legal and illegal colors are presented. The European Rapid Alert System for Food and Feed notifications and US import alerts concerning food colors are analyzed and trends in fraudulent use of color additives identified. The detection methods for synthetic colors are also reviewed.

  7. Coloring mixed hypergraphs

    CERN Document Server

    Voloshin, Vitaly I

    2002-01-01

    The theory of graph coloring has existed for more than 150 years. Historically, graph coloring involved finding the minimum number of colors to be assigned to the vertices so that adjacent vertices would have different colors. From this modest beginning, the theory has become central in discrete mathematics with many contemporary generalizations and applications. Generalization of graph coloring-type problems to mixed hypergraphs brings many new dimensions to the theory of colorings. A main feature of this book is that in the case of hypergraphs, there exist problems on both the minimum and th

  8. Photoproduction of events with rapidity gaps between jets at HERA

    Energy Technology Data Exchange (ETDEWEB)

    Chekanov, S.; Derrick, M.; Magill, S. [Argonne National Laboratory, Argonne, IL (US)] (and others)

    2006-12-15

    The photoproduction of dijet events, where the two jets with the highest transverse energy are separated by a large gap in pseudorapidity, have been studied with the ZEUS detector using an integrated luminosity of 39 pb{sup -1}. Rapidity-gap events are defined in terms of the energy flow between the jets, such that the total summed transverse energy in this region is less than some value E{sub T}{sup C}UT. The data show a clear excess over the predictions of standard photoproduction models. This is interpreted as evidence for a strongly interacting exchange of a color-singlet object. Monte Carlo models which include such a color-singlet exchange are able to describe the data. (orig.)

  9. Photoproduction of events with rapidity gaps between jets at HERA

    CERN Document Server

    Chekanov, S; Magill, S; Miglioranzi, S; Musgrave, B; Nicholass, D; Repond, J; Yoshida, R; Mattingly, M C K; Jechow, M; Pavel, N; Yagues-Molina, A G; Antonelli, S; Antonioli, P; Bari, G; Basile, M; Bellagamba, L; Bindi, M; Boscherini, D; Bruni, A; Bruni, G; Cifarelli, L; Cindolo, F; Contin, A; Corradi, M; De Pasquale, S; Iacobucci, G; Margotti, A; Nania, R; Polini, A; Rinaldi, L; Sartorelli, G; Zichichi, A; Aghuzumtsyan, G; Bartsch, D; Brock, I; Goers, S; Hartmann, H; Hilger, E; Jakob, H P; Jüngst, M; Kind, O M; Paul, E; Rautenberg, J; Renner, R; Samson, U; Schonberg, V; Wang, M; Wlasenko, M; Brook, N H; Heath, G P; Morris, J D; Namsoo, T; Capua, M; Fazio, S; Mastroberardino, A; Schioppa, M; Susinno, G; Tassi, E; Kim, J Y; Ma, K J; Ibrahim, Z A; Kamaluddin, B; Wan-Abdullah, W A T; Ning, Y; Ren, Z; Sciulli, F; Chwastowski, J; Eskreys, A; Figiel, J; Galas, A; Gil, M; Olkiewicz, K; Stopa, P; Zawiejski, L; Adamczyk, L; Bold, T; Grabowska-Bold, I; Kisielewska, D; Lukasik, J; Przybycien, M B; Suszycki, L; Kotanski, A; Slominski, W; Adler, V; Behrens, U; Bloch, I; Bonato, A; Borras, K; Coppola, N; Fourletova, J; Geiser, A; Gladkov, D; Göttlicher, P; Gregor, I; Haas, T; Hain, W; Horn, C; Kahle, B; Kötz, U; Kowalski, H; Lobodzinska, E; Löhr, B; Mankel, R; Melzer-Pellmann, I A; Montanari, A; Notz, D; Nuncio-Quiroz, A E; Santamarta, R; Schneekloth, U; Spiridonov, A A; Stadie, H; Stösslein, U; Szuba, D; Szuba, J; Theedt, T; Wolf, G; Wrona, K; Youngman, C; Zeuner, W; Schlenstedt, S; Barbagli, G; Gallo, E; Pelfer, P G; Bamberger, A; Dobur, D; Karstens, F; Vlasov, N N; Bussey, P J; Doyle, A T; Dunne, W; Ferrando, J; Saxon, D H; Skillicorn, I O; Gialas, I; Gosau, T; Holm, U; Klanner, R; Lohrmann, E; Salehi, H; Schleper, P; Schörner-Sadenius, T; Sztuk, J; Wichmann, K; Wick, K; Foudas, C; Fry, C; Long, K R; Tapper, A D; Kataoka, M; Matsumoto, T; Nagano, K; Tokushuku, K; Yamada, S; Yamazaki, Y; Barakbaev, A N; Boos, E G; Dossanov, A; Pokrovskiy, N S; Zhautykov, B O; Son, D; De Favereau, J; Piotrzkowski, K; Barreiro, F; Glasman, C; Jiménez, M; Labarga, L; Del Peso, J; Ron, E; Soares, M; Terron, J; Zambrana, M; Corriveau, F; Liu, C; Walsh, R; Zhou, C; Tsurugai, T; Antonov, A; Dolgoshein, B A; Rubinsky, I; Sosnovtsev, V; Stifutkin, A; Suchkov, S; Dementiev, R K; Ermolov, P F; Gladilin, L K; Katkov, I I; Khein, L A; Korzhavina, I A; Kuzmin, V A; Levchenko, B B; Lukina, O Yu; Proskuryakov, A S; Shcheglova, L M; Zotkin, D S; Zotkin, S A; Abt, I; Büttner, C; Caldwell, A; Kollar, D; Schmidke, W B; Sutiak, J; Grigorescu, G; Keramidas, A; Koffeman, E; Kooijman, P; Pellegrino, A; Tiecke, H G; Vázquez, M; Wiggers, L; Brümmer, N; Bylsma, B; Durkin, L S; Lee, A; Ling, T Y; Allfrey, P D; Bell, M A; Cooper-Sarkar, A M; Cottrell, A; Devenish, R C E; Foster, B; Korcsak-Gorzo, K; Patel, S; Roberfroid, V; Robertson, A; Straub, P B; Uribe-Estrada, C; Walczak, R; Bellan, P M; Bertolin, A; Brugnera, R; Carlin, R; Ciesielski, R; Dal Corso, F; Dusini, S; Garfagnini, A; Limentani, S; Longhin, A; Stanco, L; Turcato, M; Oh, B Y; Raval, A; Ukleja, J; Whitmore, J J; Iga, Y; D'Agostini, G; Marini, G; Nigro, A; Cole, J E; Hart, J C; Abramowicz, H; Gabareen, A; Ingbir, R; Kananov, S; Levy, A; Kuze, M; Hori, R; Kagawa, S; Okazaki, N; Shimizu, S; Tawara, T; Hamatsu, R; Kaji, H; Kitamura, S; Ota, O; Ri, Y D; Ferrero, M I; Monaco, V; Sacchi, R; Solano, A; Arneodo, M; Ruspa, M; Fourletov, S; Martin, J F; Boutle, S K; Butterworth, J M; Gwenlan, C; Jones, T W; Loizides, J H; Sutton, M R; Targett-Adams, C; Wing, M; Brzozowska, B; Ciborowski, J; Grzelak, G; Kulinski, P; Luzniak, P; Malka, J; Nowak, R J; Pawlak, J M; Tymieniecka, T; Ukleja, A; Zarnecki, A F; Adamus, M; Plucinsky, P P; Eisenberg, Y; Giller, I; Hochman, D; Karshon, U; Rosin, M; Brownson, E; Danielson, T; Everett, A; Kcira, D; Reeder, D D; Ryan, P; Savin, A A; Smith, W H; Wolfe, H; Bhadra, S; Catterall, C D; Cui, Y; Hartner, G; Menary, S; Noor, U; Standage, J; Whyte, J

    2006-01-01

    The photoproduction of dijet events, where the two jets with the highest transverse energy are separated by a large gap in pseudorapidity, have been studied with the ZEUS detector using an integrated luminosity of 39 pb$^{-1}$. Rapidity-gap events are defined in terms of the energy flow between the jets, such that the total summed transverse energy in this region is less than some value $E_{\\rm T}^{\\rm CUT}$. The data show a clear excess over the predictions of standard photoproduction models. This is interpreted as evidence for a strongly interacting exchange of a color-singlet object. Monte Carlo models which include such a color-singlet exchange are able to describe the data.

  10. The perceptual balance of color

    Science.gov (United States)

    McDermott, Kyle C.; Webster, Michael A.

    2011-01-01

    The cone contrasts carrying different dimensions of color vision vary greatly in magnitude, yet the perceived contrast of color and luminance in the world appears similar. We examined how this perceptual balance is adjusted by adaptation to the contrast in images. Observers set the level of L vs. M and S vs. LM contrast in 1/f noise images to match the perceived strength of a fixed level of luminance contrast. The perceptual balance of color in the images was roughly consistent with the range of contrasts characteristic of natural images. Relative perceived contrast could be strongly biased by brief prior exposure to images with lower or higher levels of chromatic contrast. Similar adaptation effects were found for luminance contrast in images of natural scenes. For both, observers reliably chose the contrast balance that appeared correct, and these choices were rapidly recalibrated by adaptation. This recalibration of the norm for contrast could reflect both changes in sensitivity and shifts in criterion. Our results are consistent with the possibility that color mechanisms adjust the range of their responses to match the range of signals in the environment, and that contrast adaptation plays an important role in these adjustments. PMID:22330367

  11. Staggered Multiple-PRF Ultrafast Color Doppler.

    Science.gov (United States)

    Posada, Daniel; Poree, Jonathan; Pellissier, Arnaud; Chayer, Boris; Tournoux, Francois; Cloutier, Guy; Garcia, Damien

    2016-06-01

    Color Doppler imaging is an established pulsed ultrasound technique to visualize blood flow non-invasively. High-frame-rate (ultrafast) color Doppler, by emissions of plane or circular wavefronts, allows severalfold increase in frame rates. Conventional and ultrafast color Doppler are both limited by the range-velocity dilemma, which may result in velocity folding (aliasing) for large depths and/or large velocities. We investigated multiple pulse-repetition-frequency (PRF) emissions arranged in a series of staggered intervals to remove aliasing in ultrafast color Doppler. Staggered PRF is an emission process where time delays between successive pulse transmissions change in an alternating way. We tested staggered dual- and triple-PRF ultrafast color Doppler, 1) in vitro in a spinning disc and a free jet flow, and 2) in vivo in a human left ventricle. The in vitro results showed that the Nyquist velocity could be extended to up to 6 times the conventional limit. We found coefficients of determination r(2) ≥ 0.98 between the de-aliased and ground-truth velocities. Consistent de-aliased Doppler images were also obtained in the human left heart. Our results demonstrate that staggered multiple-PRF ultrafast color Doppler is efficient for high-velocity high-frame-rate blood flow imaging. This is particularly relevant for new developments in ultrasound imaging relying on accurate velocity measurements.

  12. La velocidad de propagación del flujo M color es un marcador sensible de disfunción diastólica en miocardiopatía chagásica Color M flow velocity propagation is a sensible diastolic disfunction marker in Chagas cardiomyopathy

    Directory of Open Access Journals (Sweden)

    Carlos A Luengas

    2008-12-01

    ,007; p=0,02. Hubo incremento de la relación E/e del anillo mitral sólo en el grupo III (p=0,00. Se registró disminución de las velocidades e y s del anillo mitral y e del anillo tricúspide, y prolongación del tiempo de contracción isovolumétrica del ventrículo derecho a partir del grupo II. La velocidad de propagación del flujo M color mitral, tuvo una disminución constante a partir del grupo I (p=0,01; p=0,005; p=0,0002. El índice de Tei no mostró cambios significativos entre los grupos. Conclusión: la disminución de la velocidad del flujo M color por debajo de 72 cm/s fue la variable más sensible para detectar disfunción diastólica ventricular izquierda en pacientes con miocardiopatía chagásica.Introduction and Objectives: Chagasic myocardiopathy is a severe health problem in Latin America. It is the first cause of dilated cardiopathy of infectious origin in Colombia.The changes described in the evaluation of the diastolic function of patients with cardiopathy are precocious and generally precede symptoms and changes in systolic function. The objective of this study is to understand the behavior of the different variables, to evaluate the diastolic function in patients at different stages of Chagas disease, and to establish whether there are early alterations that can be predictive of the progression rate of the disease. Methods: We evaluated systolic and diastolic ventricular functions in 600 patients distributed as follows: 165 (27.5% asymptomatic patients, seronegative for Chagas disease (group 0; 277 (46.2% seropositive asymptomatic patients (group I; 116 (19.3% seropositive with right bundle branch block (group II; and 42 (7% seropositive with heart failure (group III. Mitral, tricuspid and pulmonary vein flows, Doppler of mitral and tricuspid rings, color-M mode Doppler flow propagation velocity and Tei index were measured. For the descriptive analysis, the type of variable was taken into account. To establish the frequencies behavior, the

  13. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... lentes de contacto de color Sep. 26, 2013 It started as an impulsive buy from a souvenir ... Can Ruin Vision Eye Makeup Safety In fact, it is illegal to sell colored contact lenses without ...

  14. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... colored contact lenses , from the U.S. Food and Drug Administration (FDA). Are the colored lenses you are ... from dry eye now have a completely new, drug-free alternative to lubricating eye drops and topical ...

  15. Color chiral solitons

    CERN Document Server

    Novozhilov, V Yu; Novozhilov, Victor; Novozhilov, Yuri

    2002-01-01

    We discuss specific features of color chiral solitons (asymptotics, possibility of confainment, quantization) at example of isolated SU(2) color skyrmions, i.e. skyrmions in a background field which is the vacuum field forming the gluon condensate.

  16. Color vision: retinal blues.

    Science.gov (United States)

    Johnston, Jamie; Esposti, Federico; Lagnado, Leon

    2012-08-21

    Two complementary studies have resolved the circuitry underlying green-blue color discrimination in the retina. A blue-sensitive interneuron provides the inhibitory signal required for computing green-blue color opponency.

  17. Colors Can Affect Us!

    Institute of Scientific and Technical Information of China (English)

    张俊斌

    2006-01-01

    Different colors affect us differently.The following will show us how they work. Experiment proves that math problems worked on yellow paper have fewer mistakes than problems written on other colors of paper.

  18. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Vision and Daily Eye Drops After One Use Facts About Colored Contacts and Halloween Safety Colored Contact Lens Facts Over-the-Counter Costume Contacts May Contain Chemicals ...

  19. Color: Implications in dentistry

    Directory of Open Access Journals (Sweden)

    Sikri Vimal

    2010-01-01

    Full Text Available The success of restorative dentistry is determined on the basis of functional and esthetic results. To achieve esthetics, four basic determinants are required in sequence; viz., position, contour, texture and color. The knowledge of the concept of color is essential for achieving good esthetics. This review compiles the various aspects of color, its measurements and shade matching in dentistry.

  20. Measurement of Color Texture

    NARCIS (Netherlands)

    Hoang, M.A.; Geusebroek, J.M.; Chantler, M.

    2002-01-01

    In computer vision, measurement of image properties such as color or texture is essential. In this paper, we propose a solid framework for the local measurement of texture in color images. We give a physical basis for the integration of the well-known Gabor filters with the measurement of color. Our

  1. Reimagining the Color Wheel

    Science.gov (United States)

    Snyder, Jennifer

    2011-01-01

    Color wheels are a traditional project for many teachers. The author has used them in art appreciation classes for many years, but one problem she found when her pre-service art education students created colored wheels was that they were boring: simple circles, with pie-shaped pieces, which students either painted or colored in. This article…

  2. Elliptic flow of muons from heavy-flavour hadron decays at forward rapidity in Pb–Pb collisions at sNN=2.76 TeV

    NARCIS (Netherlands)

    Peitzmann, T.; Mischke, A.; Snellings, R.J.M.; Grelli, A.

    2016-01-01

    he elliptic flow, v2v2, of muons from heavy-flavour hadron decays at forward rapidity (2.5

  3. Rapid Analysis and Evaluation of Freshness of Chilled Pork Based on Color Difference%冷却猪肉新鲜度的色差快速分析评价方法

    Institute of Scientific and Technical Information of China (English)

    陈晓亮; 王世平; 刘欢

    2012-01-01

    The variability during storage under 4℃ and 20℃of chilled pork (longissimus dorsi muscle) was studied in globulin precipitation, sensory evaluation, pH, water content and the color and color parameters of pork surface and extract. The results indicated that the variations of globulin precipitation and pH in chilled had a significant difference. The color changes such as L* of pork surface under 20 ℃ and L^*, b^*, C and △E^* of pork extract differ significantly (P〈0.05). The relationship between color changes and pH or storage time of chilled pork during storage was established. The CIE a^* under 20 ℃, b^* and C under 4℃ of pork surface as well as the L^*, b^*, C, and △E^* of pork extract under 20℃ and L^* under 4 ℃ were positively correlated with storage time. Moreover, the L^* of pork surface under 4℃, the L^*, b^*, C and △E^* of pork extract under both temperatures and a^* under 4 ~C were correlated positively with pH; when L^* 〉48.73, a^* 〉4.72 and b^* 〉9.18, chilled pork could be identified as fresh meat in cold chain.%为了得到冷却猪肉新鲜度的变化规律,本研究以冷却猪肉里脊部分为研究对象,进行球蛋白沉淀实验、感官评价、pH值、水分含量、肉浸液以及肌肉表面颜色值测定。结果表明:球蛋白沉淀实验、pH值能够较好地反应肉品新鲜度的变化,色差分析符合一定的规律:肌肉表面色差测定中,20℃条件下,a^*变化与贮藏时间显著相关(P〈0.05),L^*变化显著(P〈0.05);4℃条件下,b^*、C变化与贮藏时间极显著相关(P〈0.01),L^*值与pH值极显著相关(P〈0.01);对于肉浸液,L^*、6^*、C、△E^*均发生显著性变化(P〈0.05),20℃条件下L^*、b^*、C、△E^*与贮藏时间和pH值显著相关(P〈0.05),而4℃条件下,L^*、C、△E^*与贮藏时间显著相关(P〈0.05)

  4. Changes in color and blood flow of the tongue of HBV transgenic mice%HBV转基因小鼠的舌色改变及血流变化

    Institute of Scientific and Technical Information of China (English)

    刘文兰; 车念聪; 唐佐青; 油红捷; 杨铮

    2011-01-01

    目的:研究HBV转基因小鼠的舌色表现和微血管血流变化.方法:10只C57BL/6J-HBV转基因小鼠和10只正常小鼠(C57BL/6J非转基因小鼠),均雌雄各半,采用小鼠舌象观察装置对小鼠舌色进行观察;使用激光多普勒血流仪进行舌和肝脏微血管血流检测;断头采血,测定血清丙氨酸氨基转移酶(ALT)、门冬氨酸氨基转移酶(AST)的含量;HE染色观察肝和舌组织病理变化.结果:HBV转基因小鼠中,6只小鼠舌色呈紫色,4只舌色呈暗红色,而正常小鼠的舌色均为淡红色.HBV转基因小鼠舌色色调(H值)变深,有显著性差异(P<0.01);舌色亮度(V值)变弱,有极显著性差异(P<0.001).和正常鼠相比,紫舌HBV转基因小鼠微血管血流灌注量和血流速度显著降低(0.206±0.13 vs 0.794±0.13;0.479±0.07 vs 0.331±0.04,P<0.01,P<0.001),该模型肝脏微血管血流灌注量和血流速度显著降低,HBV转基因小鼠肝脏和舌存在明显的炎性改变.结论:HBV转基因小鼠舌色以紫色多见,其形成机制与微循环障碍有关.该模型存在肝脏和舌的炎症病理,提示炎性微环境是形成其肝脏和舌微循环障碍的重要原因.%AIM: To examine the changes in color and microvascular blood flow of the tongue of HBV transgenic mice.METHODS: Ten C57BL/6J-HBV transgenic mice and 10 normal mice were used in the study. The tongue color of the mice was observed daily. The microvascular blood flow of tongue and liver were detected with a laser Doppler blood flowmeter. Blood samples were taken to measure serum alanine aminotransferase (ALT) and aspartate aminotransferase (AST). Pathological changes in the tongue and liver were evaluated by HE staining.RESULTS: The tongue was purple in color in six HBV transgenic mice and dark red in the remaining four transgenic mice. In contrast,the tongue of normal mice was light red in color. The hue of the tongue become darker and brightness become weaker in HBV transgenic mice (0.206 ± 0

  5. Tanslation of Color Words

    Institute of Scientific and Technical Information of China (English)

    徐丹

    2009-01-01

    Being a minor part in the translation field,the translation of color words is far more complex than people may have imagined.Apart from the literal meaning of color words in the target language,there are other factors that affect the understanding.This paper mainly focuses on three main characteristics of color words that make the translation work difficult-color words'variations and combinations,rich symbolic meanings and culture differences.It also provides possible ways to deal with the prickly problem of finding equivalents,the complexity of transferring symbolic meanings and the subtle problem of crossing culture boundaries in translation of color words.

  6. Color of Meat and Poultry

    Science.gov (United States)

    ... or freezer, color changes are normal for fresh meat and poultry. 2. Does a change in color indicate spoilage? Change in color alone does not mean the product is spoiled. Color changes are normal for fresh ...

  7. Acquired color vision deficiency.

    Science.gov (United States)

    Simunovic, Matthew P

    2016-01-01

    Acquired color vision deficiency occurs as the result of ocular, neurologic, or systemic disease. A wide array of conditions may affect color vision, ranging from diseases of the ocular media through to pathology of the visual cortex. Traditionally, acquired color vision deficiency is considered a separate entity from congenital color vision deficiency, although emerging clinical and molecular genetic data would suggest a degree of overlap. We review the pathophysiology of acquired color vision deficiency, the data on its prevalence, theories for the preponderance of acquired S-mechanism (or tritan) deficiency, and discuss tests of color vision. We also briefly review the types of color vision deficiencies encountered in ocular disease, with an emphasis placed on larger or more detailed clinical investigations.

  8. 彩色多普勒超声对急性胆囊炎LC难度的预测价值%Role of color Doppler flow imaging in predicting difficulties of laparoscopic cholecystectomy

    Institute of Scientific and Technical Information of China (English)

    陈秀华; 韩秀婕; 郭发金; 周新平

    2008-01-01

    目的 探讨彩色多普勒超声(color Doppler flow imaging, CDFI)检查对急性胆囊炎LC难度的预测价值.方法 99例因急性胆囊炎行LC的患者,根据术前CDFI检查的指标(胆囊容积、胆囊壁厚度及血流信号、胆囊腔、胆囊床和肝内外胆管的情况)评分分为容易组和困难组;根据术中难度评分分为手术容易组和手术困难组,评估其对手术难度的预测价值.结果 术前CDFI预测容易组和困难组分别为67例和32例;根据术中难度评分,手术容易组和手术困难组分别为61例和38例.术前CDFI预测困难组与容易组比较,胆囊容积增大[(39.5±13.2)cm3 vs(32.6±10.4)cm3],胆囊壁增厚[(10.1±4.0)mm vs(3.8±0.9)mm],胆囊颈结石嵌顿、胆囊壁血流信号丰富和胆囊粘连的患者多于容易组,差异有统计学意义(t=-2.820,-12.318,-3.952,x2=33.548,19.461,P<0.05).以胆囊容积、胆囊壁厚度、胆囊颈结石嵌顿、胆囊周围粘连情况为预测指标,急性胆囊炎术前CDFI预测LC难度准确率为94%(93/99).结论 术前CDFI检查有助于掌握急性胆囊炎LC适应证,对手术难度预测具有指导价值.%Objective To evaluate the color Doppler flow imaging (CDFI) findings in predicting possible difficulties of laparoscopic cholecystectomy (LC). Methods A total of 99 patients with acute cholecystitis received CDFI examination, and were divided into easy LC group (n=67) and difficult LC group (n=32) according to the indexes including the volume of gallbladder, the thickness of gallbladder wall, the condition of arterial flow in the gallbladder wall, the condition of gallbladder cavity and fossa, and of the intra-and extra-hepatic bile duct. After LC, all the patients were redivided into easy LC group and difficult LC group according to a difficulty scoring system of LC. The relationship among imaging results, operation difficulties and operation findings was investigated. Results According to the final score of difficulty scoring system

  9. Colors, colored overlays, and reading skills

    Directory of Open Access Journals (Sweden)

    Arcangelo eUccula

    2014-07-01

    Full Text Available In this article, we are concerned with the role of colors in reading written texts. It has been argued that colored overlays applied above written texts positively influence both reading fluency and reading speed. These effects would be particularly evident for those individuals affected by the so called Meares-Irlen syndrome, i.e. who experience eyestrain and/or visual distortions – e.g. color, shape or movement illusions – while reading. This condition would interest the 12-14% of the general population and up to the 46% of the dyslexic population. Thus, colored overlays have been largely employed as a remedy for some aspects of the difficulties in reading experienced by dyslexic individuals, as fluency and speed. Despite the wide use of colored overlays, how they exert their effects has not been made clear yet. Also, according to some researchers, the results supporting the efficacy of colored overlays as a tool for helping readers are at least controversial. Furthermore, the very nature of the Meares-Irlen syndrome has been questioned. Here we provide a concise, critical review of the literature.

  10. Color Reproduction with a Smartphone

    Science.gov (United States)

    Thoms, Lars-Jochen; Colicchia, Giuseppe; Girwidz, Raimund

    2013-01-01

    The world is full of colors. Most of the colors we see around us can be created on common digital displays simply by superposing light with three different wavelengths. However, no mixture of colors can produce a fully pure color identical to a spectral color. Using a smartphone, students can investigate the main features of primary color addition…

  11. Color Reproduction with a Smartphone

    Science.gov (United States)

    Thoms, Lars-Jochen; Colicchia, Giuseppe; Girwidz, Raimund

    2013-01-01

    The world is full of colors. Most of the colors we see around us can be created on common digital displays simply by superposing light with three different wavelengths. However, no mixture of colors can produce a fully pure color identical to a spectral color. Using a smartphone, students can investigate the main features of primary color addition…

  12. Color camera pyrometry for high explosive detonations

    Science.gov (United States)

    Densmore, John; Biss, Matthew; Homan, Barrie; McNesby, Kevin

    2011-06-01

    Temperature measurements of high-explosive and combustion processes are difficult because of the speed and environment of the events. We have characterized and calibrated a digital high-speed color camera that may be used as an optical pyrometer to overcome these challenges. The camera provides both high temporal and spatial resolution. The color filter array of the sensor uses three color filters to measure the spectral distribution of the imaged light. A two-color ratio method is used to calculate a temperature using the color filter array raw image data and a gray-body assumption. If the raw image data is not available, temperatures may be calculated from processed images or movies depending on proper analysis of the digital color imaging pipeline. We analyze three transformations within the pipeline (demosaicing, white balance, and gamma-correction) to determine their effect on the calculated temperature. Using this technique with a Vision Research Phantom color camera, we have measured the temperature of exploded C-4 charges. The surface temperature of the resulting fireball rapidly increases after detonation and then decayed to a constant value of approximately 1980 K. Processed images indicates that the temperature remains constant until the light intensity decreased below the background value.

  13. with Ultrasound Color Doppler Imaging

    Directory of Open Access Journals (Sweden)

    Shin Takayama

    2012-01-01

    Full Text Available Color Doppler imaging (CDI can be used to noninvasively create images of human blood vessels and quantitatively evaluate blood flow in real-time. The purpose of this study was to assess the effects of acupuncture on the blood flow of the peripheral, mesenteric, and retrobulbar arteries by CDI. Statistical significance was defined as P values less than 0.05. Blood flow in the radial and brachial arteries was significantly lower during needle stimulation on LR3 than before in healthy volunteers, but was significantly higher after needle stimulation than before. LR3 stimulation also resulted in a significant decrease in the vascular resistance of the short posterior ciliary artery and no significant change of blood flow through the superior mesenteric artery (SMA during acupuncture. In contrast, ST36 stimulation resulted in a significant increase in blood flow through the SMA and no significant change in the vascular resistance of the retrobulbar arteries. Additionally, acupuncture at previously determined acupoints in patients with open-angle glaucoma led to a significant reduction in the vascular resistance of the central retinal artery and short posterior ciliary artery. Our results suggest that acupuncture can affect blood flow of the peripheral, mesenteric, and retrobulbar arteries, and CDI can be useful to evaluate hemodynamic changes by acupuncture.

  14. Affective Image Colorization

    Institute of Scientific and Technical Information of China (English)

    Xiao-Hui Wang; Jia Jia; Han-Yu Liao; Lian-Hong Cai

    2012-01-01

    Colorization of gray-scale images has attracted many attentions for a long time.An important role of image color is the conveyer of emotions (through color themes).The colorization with an undesired color theme is less useful,even it is semantically correct.However this has been rarely considered.Automatic colorization respecting both the semantics and the emotions is undoubtedly a challenge.In this paper,we propose a complete system for affective image colorization.We only need the user to assist object segmentation along with text labels and an affective word.First,the text labels along with other object characters are jointly used to filter the internet images to give each object a set of semantically correct reference images.Second,we select a set of color themes according to the affective word based on art theories.With these themes,a generic algorithm is used to select the best reference for each object,balancing various requirements.Finally,we propose a hybrid texture synthesis approach for colorization.To the best of our knowledge,it is the first system which is able to efficiently colorize a gray-scale image semantically by an emotionally controllable fashion.Our experiments show the effectiveness of our system,especially the benefit compared with the previous Markov random field (MRF) based method.

  15. The nature of colors

    Science.gov (United States)

    da Pos, Osvaldo

    2002-06-01

    Color is a visible aspect of objects and lights, and as such is an objective characteristic of our phenomenal world. Correspondingly also objects and lights are objective, although their subjectivity cannot be disregarded since they belong to our phenomenal world. The distinction between perception and sensation deals with colors seen either in complex displays or in isolation. Reality of colors is apparently challenged by virtual reality, while virtual reality is a good example of what colors are. It seems difficult to combine that aspect of reality colors have in our experience and the concept that colors represent something in the external environment: the distinction between stimulation and perceived object is crucial for understanding the relationships between phenomenal world and physical reality. A modern concept of isomorphism seems useful in interpreting the role of colors. The relationship between the psychological structure of colors and the physical stimulation is enlightened by the analysis of pseudocolors. The perceptual, subjective characteristics of colors go along with the subjectivity of scientific concepts. Colors, emotions, and concepts are all in some people's mind: none of them is independent of the subject mind. Nevertheless they can be communicated from person to person by an appropriate scientific terminology.

  16. 'Clovis' in Color

    Science.gov (United States)

    2004-01-01

    [figure removed for brevity, see original site] Figure 1 This approximate true-color image taken by the Mars Exploration Rover Spirit shows the rock outcrop dubbed 'Clovis.' The rock was discovered to be softer than other rocks studied so far at Gusev Crater after the rover easily ground a hole into it with its rock abrasion tool. This image was taken by the 750-, 530- and 480-nanometer filters of the rover's panoramic camera on sol 217 (August 13, 2004). Elemental Trio Found in 'Clovis' Figure 1 above shows that the interior of the rock dubbed 'Clovis' contains higher concentrations of sulfur, bromine and chlorine than basaltic, or volcanic, rocks studied so far at Gusev Crater. The data were taken by the Mars Exploration Rover Spirit's alpha particle X-ray spectrometer after the rover dug into Clovis with its rock abrasion tool. The findings might indicate that this rock was chemically altered, and that fluids once flowed through the rock depositing these elements.

  17. Selection of small color palette for color image quantization

    Science.gov (United States)

    Chau, Wing K.; Wong, S. K. M.; Yang, Xuedong; Wan, Shijie J.

    1992-05-01

    Two issues are involved in color image quantization: color palette selection and color mapping. A common practice for color palette selection is to minimize the color distortion for each pixel (the median-cut, the variance-based and the k-means algorithms). After the color palette has been chosen, a quantized image may be generated by mapping the original color of each pixel onto its nearest color in the color palette. Such an approach can usually produce quantized images of high quality with 128 or more colors. For 32 - 64 colors, the quality of the quantized images is often acceptable with the aid of dithering techniques in the color mapping process. For 8 - 16 color, however, the above statistical method for color selection becomes no longer suitable because of the great reduction of color gamut. In order to preserve the color gamut of the original image, one may want to select the colors in such a way that the convex hull formed by these colors in the RGB color space encloses most colors of the original image. Quantized images generated in such a geometrical way usually preserve a lot of image details, but may contain too much high frequency noises. This paper presents an effective algorithm for the selection of very small color palette by combining the strengths of the above statistical and geometrical approaches. We demonstrate that with the new method images of high quality can be produced by using only 4 to 8 colors.

  18. 乳腺增生病的彩色多普勒超声诊断与病理对照分析%Galactophore hyperplasia:a comparative analysis between color doppler flow imaging and pathology

    Institute of Scientific and Technical Information of China (English)

    韩曼彤; 陈念德; 冼兆新

    2001-01-01

    Objective:To evaluate the value of two-dimensional sonogram andcolor Doppler Flow Imaging(CDFI) in diagnosing galactophore hyperplasia(PH).Methods:A retrospective analysis of the two dimensional sonogram and CDFI features was conducted to 40 cases of galactophore hyperplasis confirmed by patholgy,and the results were compared to the findings of pathology.Results:The correct rate of ultrasound diagnosis was 80%.The sonograms of PH could be divided into three types in accordance with pathological morphology which are simple hyperplasis, cystic hyperplasia and adenoidal hyperplasia.In 10% cases of PH,color signal could be detected.Conclusion:Two-dimensional sonogram,together with CDFI,has shown some clinical significance to the diagnosis of PH.%目的:探讨二维声像图及CDFI对乳腺增生病的诊断价值。方法:对40例经手术病理或病理活检证实为乳腺增生病的二维声像图及CDFI表现进行了分析,并与病理分型作对照。结果:本文的超声诊断正确率为80%。按其病理分为单纯性增生,囊性增生,腺型增生三种。此病血流信号检出率为10%(4/40)。结论:二维声像图加CDFI诊断本病符合率高,是有一定的临床价值。

  19. A novel 8-color flow cytometry panel to study activation, maturation and senescence of CD4 and CD8 T lymphocytes in HIV-infected individuals at different stages of disease.

    Science.gov (United States)

    Bordoni, V; Casetti, R; Capuano, G; De Stefani, B; Piselli, P; Gioia, C; Agrati, C; Martini, F

    2012-01-01

    Multicolor flow cytometry allows to study the markers differentially expressed during maturation, activation, function and senescence on immune cells. Despite the availability of reagents and technology, scarce agreement has been gained regarding phenotypic markers of HIV disease progression other than CD4 T-cell count. In this work, we present a novel high-throughput global analysis of CD4 and CD8 T-lymphocyte profiles by standardized 8-color combinations of antibodies aimed at analyzing HIV disease course progression. For this purpose, two tubes with lyophilized reagent cocktails (CD4- and CD8-specific tubes) were designed to compare the immunological characteristics of HIV-infected persons (37 "high CD4" HAART-treated and 32 "low CD4" naïve or failed-treatment patients) with healthy donors (HD). In particular, T-cell activation (CD25, CD38, CD69), differentiation (CD45RA, CCR7), apoptosis (CD95) and immune suppression profiles (CD25(high)CD127-) in HIV+ patients were compared with HD. Statistical analysis was performed by identifying the parameters associated with disease progression, namely markers that were found to be significantly different between groups with high CD4 counts (including HD) and low CD4 counts (restricted to HIV patients) but not between the HD and the "high CD4" group. This set of markers, including those identifying different maturation and senescence subtypes of CD4 and CD8 T cells, was found to be associated with therapy failure, and it is in fact evaluated in an ongoing study aimed to verify its prognostic value. This robust assay was found feasible on a semi-routine scale for HIV-infected persons, and allows for broader clinical studies aimed at defining markers associated with treatment outcome, possibly having a high impact on the clinical management of HIV disease.

  20. Statistics of natural scenes and the cortical representation of color

    Science.gov (United States)

    Cecchi, G. A.; Rao, A. R.; Xiao, Y.; Kaplan, E.

    2008-02-01

    In this paper we investigate the spatial correlational structure of orientation and color information in natural images. We compare these with the spatial correlation structure of optical recordings of macaque monkey primary visual cortex, in response to oriented and color stimuli. We show that the correlation of orientation falls off rapidly over increasing distance. By using a color metric based on the a-b coordinates in the CIE-Lab color space, we show that color information, on the other hand, is more highly correlated over larger distances. We also show that orientation and color information are statistically independent in natural images. We perform a similar spatial correlation analysis of the cortical responses to orientation and color. We observe a similar behavior to that of natural images, in that the correlation of orientation-specific responses falls off; more rapidly than the correlation of color-specific responses. Our findings suggest that: (a) orientation and color information should be processed in separate channels, and (b) the organization of cortical color responses at a lower spatial frequency compared to orientation is a reflection of the statistical structure of visual world.

  1. PERANCANGAN SISTEM PENJADWALAN PEMBELAJARAN MENGGUNAKAN GRAPH COLORING

    Directory of Open Access Journals (Sweden)

    Taufik Hidayatulloh

    2016-03-01

    Full Text Available Abstract - In learning scheduling problem often faced by schools in the new academic year. Sometimes collisions on the schedule was not found when the learning process has begun, so it is necessary to re-schedule on the schedule. And this resulted in the teaching and learning first weeks less to run well. Researchers previously have used various methods to solve the scheduling as Tabu search, Simulated Annealing, Network Flow, Graph Coloring. Graph Coloring (coloring of a graph is the simplest method and the experimental results indicate that the development of methods of scheduling Graph Coloring deliver results that meet an average of 93% across the specified constraints. At the time of split schedules that require extra energy at the start of learning did not experience a collision. With this system is expected to facilitate the allocation of space, teachers, lessons to avoid a collision. Keywords: Information Systems, Scheduling, graph coloring Abstraksi - Dalam masalah penjadwalan pembelajaran sering dihadapi sekolah pada tahun ajaran baru. Terkadang tabrakan pada jadwal itu baru ditemukan ketika proses belajar mengajar telah dimulai, sehingga perlu dilakukan penjadwalan ulang pada jadwal tersebut. Dan hal ini mengakibatkan kegiatan belajar mengajar pada minggu-minggu pertama kurang dapat berjalan dengan baik. Para peneliti sebelumnya telah menggunakan berbagai metode untuk memecahkan penjadwalan seperti Tabu search, Simulated Annealing, Network Flow, Graph Coloring. Graph Coloring (pewarnaan graf merupakan metode yang paling sederhana dan hasil percobaan menunjukkan bahwa pengembangan metode Graph Coloring memberikan hasil penjadwalan yang memenuhi rata-rata 93% seluruh constraints yang ditentukan. Pada saat membagi jadwal memerlukan energi ekstra agar pada saat di mulai pembelajaran tidak mengalami tabrakan. Dengan sistem ini diharapkan dapat mempermudah dalam mengalokasikan ruangan, guru, pelajaran agar tidak mengalami tabrakan. Kata

  2. The road coloring problem

    CERN Document Server

    Trahtman, A N

    2007-01-01

    The synchronizing word of deterministic automaton is a word in the alphabet of colors (considered as letters) of its edges that maps the automaton to a single state. A coloring of edges of a directed graph is synchronizing if the coloring turns the graph into deterministic finite automaton possessing a synchronizing word. The road coloring problem is a problem of synchronizing coloring of directed finite strongly connected graph with constant outdegree of all its vertices if the greatest common divisor of lengths of all its cycles is one. The problem was posed by Adler, Goodwyn and Weiss over 30 years ago and evoked a noticeable interest among the specialists in theory of graphs, deterministic automata and symbolic dynamics. The problem is described even in "Vikipedia" - the popular Internet Encyclopedia. The positive solution of the road coloring problem is presented.

  3. Laser color recording unit

    Science.gov (United States)

    Jung, E.

    1984-05-01

    A color recording unit was designed for output and control of digitized picture data within computer controlled reproduction and picture processing systems. In order to get a color proof picture of high quality similar to a color print, together with reduced time and material consumption, a photographic color film material was exposed pixelwise by modulated laser beams of three wavelengths for red, green and blue light. Components of different manufacturers for lasers, acousto-optic modulators and polygon mirrors were tested, also different recording methods as (continuous tone mode or screened mode and with a drum or flatbed recording principle). Besides the application for the graphic arts - the proof recorder CPR 403 with continuous tone color recording with a drum scanner - such a color hardcopy peripheral unit with large picture formats and high resolution can be used in medicine, communication, and satellite picture processing.

  4. The Translation Of Colors

    Institute of Scientific and Technical Information of China (English)

    王冰

    2012-01-01

    Different nations have different or even opposite perception of color, which results in non-equivalence of color words in mutual translation between Chinese and English. This paper is to discuss non-equivalence of color words between Chinese and English on the two aspects and emphasizes the importance of transmitting cultural message accurately in the mutual translation between Chinese and English. Studying the cultural connotations of the words is of great importance for successful communication.

  5. Color sensing under microwaves

    Science.gov (United States)

    Choudhury, Debesh

    2013-09-01

    Inspired by recent results of artificial color due to Caulfield, we carry out intuitive experimental investigations on color sensing under microwave illumination. Experiemnts have been carried out using a Gunn diode as the microwave source and a microwave diode as a detector. More precise experimental studies have also been carried out utilizing a vector network analyzer. Preliminary results of the experiments validate the feasibility of sensing and discriminating otherwise visual colors under microwave illumination. Caulfield's presumption possibly paves the way for artificial color perception using microwaves.

  6. Encyclopedia of color science and technology

    CERN Document Server

    2016-01-01

    The Encyclopedia of Color Science and Technology provides an authoritative single source for understanding and applying the concepts of color to all fields of science and technology, including artistic and historical aspects of color. Many topics are discussed in this timely reference, including an introduction to the science of color, and entries on the physics, chemistry and perception of color. Color is described as it relates to optical phenomena of color and continues on through colorants and materials used to modulate color and also to human vision of color. The measurement of color is provided as is colorimetry, color spaces, color difference metrics, color appearance models, color order systems and cognitive color. Other topics discussed include industrial color, color imaging, capturing color, displaying color and printing color. Descriptions of color encodings, color management, processing color and applications relating to color synthesis for computer graphics are included in this work. The Encyclo...

  7. 16S rRNA in situ Hybridization Followed by Flow Cytometry for Rapid Identification of Acetic Acid Bacteria Involved in Submerged Industrial Vinegar Production

    Directory of Open Access Journals (Sweden)

    Luka Lipoglavšek

    2016-01-01

    Full Text Available Acetic acid bacteria are involved in many biotechnological processes such as vitamin C, gluconic acid, miglitol or acetic acid production, and others. For a technologist trying to control the industrial process, the ability to follow the microbiological development of the process is thus of importance. During the past few years hybridization in a combination with flow cytometry has often been used for this purpose. Since vinegar is a liquid, it is an ideal matrix for flow cytometry analysis. In this work we have constructed a specific probe for highly acetic acid-resistant species of the acetic acid bacteria and a protocol for in situ hybridization, which in combination with flow cytometry enables direct monitoring of bacteria producing vinegar with >10 % of acetic acid. The approach was successfully applied for monitoring microbiota during industrial vinegar production.

  8. Potential of cross-priming amplification and DNA-based lateral-flow strip biosensor for rapid on-site GMO screening.

    Science.gov (United States)

    Huang, Xin; Zhai, Congcong; You, Qimin; Chen, Hongjun

    2014-07-01

    The requirement to monitor the presence of genetically modified organisms (GMO) in a variety of marked products has generated an increasing demand for reliable, rapid, and time and cost-effective analytical methods. Here we report an on-site method for rapid detection of cauliflower mosaic virus promoter (CaMV 35S), a common element present in most GMO, using cross-priming amplification (CPA) technology. Detection was achieved using a DNA-based contamination-proof strip biosensor. The limit of detection was 30 copies for the pBI121 plasmid containing the CaMV 35S gene. The certified reference sample of GM maize line MON810 was detectable even at the low relative mass concentration of 0.05%. The developed CPA method had high specificity for the CaMV 35S gene, as compared with other GM lines not containing this gene and non-GM products. The method was further validated using nine real-world samples, and the results were confirmed by real-time PCR analysis. Because of its simplicity, rapidity, and high sensitivity, this method of detecting the CaMV 35S gene has great commercial prospects for rapid GMO screening of high-consumption food and agriculture products.

  9. Flow cytometry pulse width data enables rapid and sensitive estimation of biomass dry weight in the microalgae Chlamydomonas reinhardtii and Chlorella vulgaris.

    Directory of Open Access Journals (Sweden)

    Maurizio Chioccioli

    Full Text Available Dry weight biomass is an important parameter in algaculture. Direct measurement requires weighing milligram quantities of dried biomass, which is problematic for small volume systems containing few cells, such as laboratory studies and high throughput assays in microwell plates. In these cases indirect methods must be used, inducing measurement artefacts which vary in severity with the cell type and conditions employed. Here, we utilise flow cytometry pulse width data for the estimation of cell density and biomass, using Chlorella vulgaris and Chlamydomonas reinhardtii as model algae and compare it to optical density methods. Measurement of cell concentration by flow cytometry was shown to be more sensitive than optical density at 750 nm (OD750 for monitoring culture growth. However, neither cell concentration nor optical density correlates well to biomass when growth conditions vary. Compared to the growth of C. vulgaris in TAP (tris-acetate-phosphate medium, cells grown in TAP + glucose displayed a slowed cell division rate and a 2-fold increased dry biomass accumulation compared to growth without glucose. This was accompanied by increased cellular volume. Laser scattering characteristics during flow cytometry were used to estimate cell diameters and it was shown that an empirical but nonlinear relationship could be shown between flow cytometric pulse width and dry weight biomass per cell. This relationship could be linearised by the use of hypertonic conditions (1 M NaCl to dehydrate the cells, as shown by density gradient centrifugation. Flow cytometry for biomass estimation is easy to perform, sensitive and offers more comprehensive information than optical density measurements. In addition, periodic flow cytometry measurements can be used to calibrate OD750 measurements for both convenience and accuracy. This approach is particularly useful for small samples and where cellular characteristics, especially cell size, are expected to vary

  10. 经阴道三维超声结合透明成像诊断宫腔内疾患%The value of transvaginal color Doppler flow imaging in diagnosis of intrauterine disease

    Institute of Scientific and Technical Information of China (English)

    卢峻; 王慧芳; 孙枫; 熊奕; 彭启慧; 林琪; 徐金锋; 吴瑛

    2011-01-01

    Objective : To assess the value of transvaginal 3D sonogrphy and glass body image in the diagnosis of intrauterine disease. Methods : Transvaginal 3D sonography and glass body image were performed in 67 patients with suspected intrauterine disease. The ultrasonic findings were correlated with pathological findings. Results : The endometrium interruption surrounding submucosal myoma could be showed more accurately by 3D sonography. The glass body image could be more sensitive in the detecton of peripheral color ring , which was demonstrated as a characteristic "fire ball" image , than 2D sonography. Furthermore,the internal structure of endometrial polyps and the endometrial continuity surrounding the polyps could be showed up in 3D ultrasound. The glass body image demonstrated that color flow in endometrial polyp was not rich. The rim of the endomitrum,internal echo change, the depth of myometrial invasion and the abundant internal vascularity could be more clearly showed in the 3D sonography. Conclusion: 3D sonography has important value in the early detection of intrauterine disease.%目的:探讨经阴道三维超声与透明成像在诊断宫腔内疾患的临床价值.方法:对我院疑有宫腔内赘生物67例住院患者行经阴道超声检查,并取其三维及透明成像(三维血流成像),并与病理诊断结果进行对照分析.结果:三维超声可更清晰显示黏膜下肌瘤周边的子宫内膜中断,透明成像对子宫黏膜下肌瘤周边环形血流比彩色多普勒血流显示更敏感,呈现一种特征性的"火球"样图像,与二维超声相比有极显著优势(P<0.01).三维超声可更清晰显示息肉的内部结构及内膜周边的完好连续性,透明成像显示其内血流信号不甚丰富.三维超声可更清晰显示早期内膜癌患者内膜边缘的状态及内部回声的变化,易于观察肌层侵润的深度,病变区丰富及走形紊乱的血流信号,较二维超声有显著优势(P<0.05).结论:经

  11. Information system for administrating and distributing color images through internet

    Directory of Open Access Journals (Sweden)

    2007-01-01

    Full Text Available The information system for administrating and distributing color images through the Internet ensures the consistent replication of color images, their storage - in an on-line data base - and predictable distribution, by means of a digitally distributed flow, based on Windows platform and POD (Print On Demand technology. The consistent replication of color images inde-pendently from the parameters of the processing equipment and from the features of the programs composing the technological flow, is ensured by the standard color management sys-tem defined by ICC (International Color Consortium, which is integrated by the Windows operation system and by the POD technology. The latter minimize the noticeable differences between the colors captured, displayed or printed by various replication equipments and/or edited by various graphical applications. The system integrated web application ensures the uploading of the color images in an on-line database and their administration and distribution among the users via the Internet. For the preservation of the data expressed by the color im-ages during their transfer along a digitally distributed flow, the software application includes an original tool ensuring the accurate replication of colors on computer displays or when printing them by means of various color printers or presses. For development and use, this application employs a hardware platform based on PC support and a competitive software platform, based on: the Windows operation system, the .NET. Development medium and the C# programming language. This information system is beneficial for creators and users of color images, the success of the printed or on-line (Internet publications depending on the sizeable, predictable and accurate replication of colors employed for the visual expression of information in every activity fields of the modern society. The herein introduced information system enables all interested persons to access the

  12. The Color of Lobsters

    NARCIS (Netherlands)

    Wijk, Arjan van

    2005-01-01

    Synthesis of 13C-enriched carotenoids. Carotenoids are natural colorants, ranging in color from pale yellow to deep purple, with important biological functions. Carotenoids in the human diet have a beneficial health effect, playing a role in the prevention of cardiovascular disease and cancer. To ge

  13. List coloring with requests

    OpenAIRE

    Dvořák, Zdeněk; Norin, Sergey; Postle, Luke

    2016-01-01

    Let G be a graph with a list assignment L. Suppose a preferred color is given for some of the vertices; how many of these preferences can be respected when L-coloring G? We explore several natural questions arising in this context, and propose directions for further research.

  14. Measurement of Color Texture

    NARCIS (Netherlands)

    Hoang, M.A.; Geusebroek, J.M.; Deprettere, E.F.; Belloum, A.; Heijnsdijk, J.W.J.; van der Stappen, F.

    2002-01-01

    In computer vision, measurement of image properties such as color or texture is essential. However, existing methods for measuring color and texture in combination are not well-defined neither from a measurement theoretical basis nor from a physical point of view. We propose a solid framework for th

  15. Plasmonic color tuning

    Science.gov (United States)

    Lee, Byoungho; Yun, Hansik; Lee, Seung-Yeol; Kim, Hwi

    2016-03-01

    In general, color filter is an optical component to permit the transmission of a specific color in cameras, displays, and microscopes. Each filter has its own unchangeable color because it is made by chemical materials such as dyes and pigments. Therefore, in order to express various colorful images in a display, one pixel should have three sub-pixels of red, green, and blue colors. Here, we suggest new plasmonic structure and method to change the color in a single pixel. It is comprised of a cavity and a metal nanoaperture. The optical cavity generally supports standing waves inside it, and various standing waves having different wavelength can be confined together in one cavity. On the other hand, although light cannot transmit sub-wavelength sized aperture, surface plasmons can propagate through the metal nanoaperture with high intensity due to the extraordinary transmission. If we combine the two structures, we can organize the spatial distribution of amplitudes according to wavelength of various standing waves using the cavity, and we can extract a light with specific wavelength and amplitude using the nanoaperture. Therefore, this cavity-aperture structure can simultaneously tune the color and intensity of the transmitted light through the single nanoaperture. We expect that the cavity-apertures have a potential for dynamic color pixels, micro-imaging system, and multiplexed sensors.

  16. The Color of Lobsters

    NARCIS (Netherlands)

    Wijk, Arjan van

    2005-01-01

    Synthesis of 13C-enriched carotenoids. Carotenoids are natural colorants, ranging in color from pale yellow to deep purple, with important biological functions. Carotenoids in the human diet have a beneficial health effect, playing a role in the prevention of cardiovascular disease and cancer. To ge

  17. 3-D Color Wheels

    Science.gov (United States)

    DuBois, Ann

    2010-01-01

    The blending of information from an academic class with projects from art class can do nothing but strengthen the learning power of the student. Creating three-dimensional color wheels provides the perfect opportunity to combine basic geometry knowledge with color theory. In this article, the author describes how her seventh-grade painting…

  18. Quorum Colorings of Graphs

    NARCIS (Netherlands)

    S.M. Heditniemi (Sandra); R.C. Laskar (R.C.); H.M. Mulder (Martyn)

    2012-01-01

    textabstractLet $G = (V,E)$ be a graph. A partition $\\pi = \\{V_1, V_2, \\ldots, V_k \\}$ of the vertices $V$ of $G$ into $k$ {\\it color classes} $V_i$, with $1 \\leq i \\leq k$, is called a {\\it quorum coloring} if for every vertex $v \\in V$, at least half of the vertices in the closed neighborhood

  19. Gauge color codes

    DEFF Research Database (Denmark)

    Bombin Palomo, Hector

    2015-01-01

    Color codes are topological stabilizer codes with unusual transversality properties. Here I show that their group of transversal gates is optimal and only depends on the spatial dimension, not the local geometry. I also introduce a generalized, subsystem version of color codes. In 3D they allow...

  20. The Colored Jones Function

    Institute of Scientific and Technical Information of China (English)

    HAN You-fa; YAN Xin-ming; LV Li-li

    2012-01-01

    In this paper,we discuss the properties of the colored Jones function of knots.Particularly,we calculate the colored Jones function of some knots(31,41,51,52).Furthermore,one can compute the Kashaev's invariants and study some properties of the Kashaev's conjecture.

  1. 3-D Color Wheels

    Science.gov (United States)

    DuBois, Ann

    2010-01-01

    The blending of information from an academic class with projects from art class can do nothing but strengthen the learning power of the student. Creating three-dimensional color wheels provides the perfect opportunity to combine basic geometry knowledge with color theory. In this article, the author describes how her seventh-grade painting…

  2. The color of money

    DEFF Research Database (Denmark)

    Ásgeirsson, Árni Gunnar; Kristjánsson, Árni; Einarsdóttir, Kristin Vala

    2014-01-01

    of attention are affected by reward, and whether the effect involves general enhancement or is specific to discrete components of attention. Observers viewed brief displays of differentially colored letters and reported their identity. Each color signified a consistent monetary value and we measured...

  3. Image color reduction method for color-defective observers using a color palette composed of 20 particular colors

    Science.gov (United States)

    Sakamoto, Takashi

    2015-01-01

    This study describes a color enhancement method that uses a color palette especially designed for protan and deutan defects, commonly known as red-green color blindness. The proposed color reduction method is based on a simple color mapping. Complicated computation and image processing are not required by using the proposed method, and the method can replace protan and deutan confusion (p/d-confusion) colors with protan and deutan safe (p/d-safe) colors. Color palettes for protan and deutan defects proposed by previous studies are composed of few p/d-safe colors. Thus, the colors contained in these palettes are insufficient for replacing colors in photographs. Recently, Ito et al. proposed a p/dsafe color palette composed of 20 particular colors. The author demonstrated that their p/d-safe color palette could be applied to image color reduction in photographs as a means to replace p/d-confusion colors. This study describes the results of the proposed color reduction in photographs that include typical p/d-confusion colors, which can be replaced. After the reduction process is completed, color-defective observers can distinguish these confusion colors.

  4. Aspects of Color Superconductivity

    CERN Document Server

    Hong, D K

    2001-01-01

    I discuss some aspects of recent developments in color superconductivity in high density quark matter. I calculate the Cooper pair gap and the critical points at high density, where magnetic gluons are not screened. The ground state of high density QCD with three light flavors is shown to be a color-flavor locking state, which can be mapped into the low-density hadronic phase. The meson mass at the CFL superconductor is also calculated. The CFL color superconductor is bosonized, where the Fermi sea is identified as a $Q$-matter and the gapped quarks as topological excitations, called superqualitons, of mesons. Finally, as an application of color supercoductivity, I discuss the neutrino interactions in the CFL color superconductor.

  5. Color Medical Image Analysis

    CERN Document Server

    Schaefer, Gerald

    2013-01-01

    Since the early 20th century, medical imaging has been dominated by monochrome imaging modalities such as x-ray, computed tomography, ultrasound, and magnetic resonance imaging. As a result, color information has been overlooked in medical image analysis applications. Recently, various medical imaging modalities that involve color information have been introduced. These include cervicography, dermoscopy, fundus photography, gastrointestinal endoscopy, microscopy, and wound photography. However, in comparison to monochrome images, the analysis of color images is a relatively unexplored area. The multivariate nature of color image data presents new challenges for researchers and practitioners as the numerous methods developed for monochrome images are often not directly applicable to multichannel images. The goal of this volume is to summarize the state-of-the-art in the utilization of color information in medical image analysis.

  6. Color vision and dentistry.

    Science.gov (United States)

    Wasson, W; Schuman, N

    1992-05-01

    Color vision is a critical component of restorative and esthetic dentistry, but dentists, as a group, do not have their color vision tested at any time during their careers. A study was undertaken to ascertain the color-vision status of practicing dental personnel at the University of Tennessee, College of Dentistry. One hundred fifty individuals, 75 men and 75 women, were screened. The results corroborated the existing medical data for the general population. It was found that 9.3% of the men and none of the women exhibited color-vision defect. Since most dentists are male, this study demonstrates an area of potential weakness for some practitioners. Once a color-vision problem is found, it is simple to remedy by employing a team approach to shade matching or mechanical means of matching shades (by the practitioner). No ethnic or racial distinctions were detected, although these have been reported in other studies.

  7. The study of color doppler flow imaging with thyroid-associated ophthalmopathy%甲状腺相关眼病彩色多普勒血流成像特点的研究

    Institute of Scientific and Technical Information of China (English)

    赵亮; 孙丰源; 唐东润; 吴桐

    2013-01-01

    and the clinical characteristics.At last,discuss the different influence factors on retinal blood supply of patients with TAO.Methods Use the U.S.company GE's Logic7 Color Doppler Ultrasound diagnostic apparatus,to detect the ophthalmic artery and central retinal artery on 49 TAO cases (90 eyes) whose thyroid function was normal or stable over six months and 24 normal controls (48 eyes),simultaneously,record its spectrum and measure the peak systolic velocity (PSV),enl diastolic velocity (EDV),resistance index (RI).To analyze the differences among the blood flow parameters were significant,and analyze the correlation between the blood flow parameters and the clinical characteristics.Results (1)The PSV and EDV in normal control group were higher than in TAO group,and the RI in normal group was lower than in TAO group,P <0.05; The constituent ratio of the eyes whose CRA spectrum was interrupted was higher in TAO group than in normal control group,P <0.05.(2)The CRA PSV in spectrum interruption group was lower than in spectrum without interruption group,P <0.05; The EDV of OA and CRA in spectrum interruption group was lower than in spectrum without interruption group,P <0.05; The RI of OA and CRA in spectrum interruption group was higher than in spectrum without interruption group,P <0.05.There was statistical significance for the differences of orbital pressure and exophthalmos between the spectrum inte,rruption group and spectrum without interruption group; (3)Either the PSV or the EDV of OA and CRA in normal control were higher than in spectrum interruption group,P<0.05; The RI of OA and CRA in normal control were lower than in spectrum interruption group,P<0.05.(4)The EDV of OA in normal control group was higher than in spectrum without interruption group,P <0.05; The RI of OA in normal control group was lower than in spectrum without interruption group,P <0.05; The PSV and EDV of CRA in normal control group were higher than in spectrum without

  8. Colloidal assembly in Leidenfrost drops for noniridescent structural color pigments.

    Science.gov (United States)

    Lim, Che Ho; Kang, Hyelim; Kim, Shin-Hyun

    2014-07-22

    Noniridescent structural color pigments have great potential as alternatives to conventional chemical color pigments in many coloration applications due to their nonbleaching and color-tunable properties. In this work, we report a novel method to create photonic microgranules composed of glassy packing of silica particles and small fraction of carbon black nanoparticles, which show pronounced structural colors with low angle-dependency. To prepare isotropic random packing in each microgranule, a Leidenfrost drop, which is a drop levitated by its own vapor on a hot surface, is employed as a template for fast consolidation of silica particles. The drop randomly migrates over the hot surface and rapidly shrinks, while maintaining its spherical shape, thereby consolidating silica particles to granular structures. Carbon black nanoparticles incorporated in the microgranules suppress incoherent multiple scattering, thereby providing improved color contrast. Therefore, photonic microgranules in a full visible range can be prepared by adjusting the size of silica particles with insignificant whitening.

  9. CHO-S Antibody Titers >1 Gram/Liter Using Flow Electroporation-Mediated Transient Gene Expression followed by Rapid Migration to High-Yield Stable Cell Lines

    OpenAIRE

    Steger, Krista; Brady, James; WANG, WEILI; Duskin, Meg; Donato, Karen; Peshwa, Madhusudan

    2015-01-01

    In recent years, researchers have turned to transient gene expression (TGE) as an alternative to CHO stable cell line generation for early-stage antibody development. Despite advances in transfection methods and culture optimization, the majority of CHO-based TGE systems produce insufficient antibody titers for extensive use within biotherapeutic development pipelines. Flow electroporation using the MaxCyte STX Scalable Transfection System is a highly efficient, scalable means of CHO-based TG...

  10. Stool Color: When to Worry

    Science.gov (United States)

    Stool color: When to worry Yesterday, my stool color was bright green. Should I be concerned? Answers from Michael ... M.D. Stool comes in a range of colors. All shades of brown and even green are ...

  11. Color-avoiding percolation

    CERN Document Server

    Krause, Sebastian M; Zlatić, Vinko

    2016-01-01

    Many real world networks have groups of similar nodes which are vulnerable to the same failure or adversary. Nodes can be colored in such a way that colors encode the shared vulnerabilities. Using multiple paths to avoid these vulnerabilities can greatly improve network robustness. Color-avoiding percolation provides a theoretical framework for analyzing this scenario, focusing on the maximal set of nodes which can be connected via multiple color-avoiding paths. In this paper we extend the basic theory of color-avoiding percolation that was published in [Krause et. al., Phys. Rev. X 6 (2016) 041022]. We explicitly account for the fact that the same particular link can be part of different paths avoiding different colors. This fact was previously accounted for with a heuristic approximation. We compare this approximation with a new, more exact theory and show that the new theory is substantially more accurate for many avoided colors. Further, we formulate our new theory with differentiated node functions, as s...

  12. Study of ovarian artery blood flow in ovulatory phase by transvaginal color Doppler ultrasound%经阴道彩色多普勒超声对排卵期卵巢动脉血流动力学研究

    Institute of Scientific and Technical Information of China (English)

    程遵华; 项晓宇; 董莉; 童仙君; 谈媛

    2011-01-01

    Objective To explore the changes of ovarian artery blood flow during follicle maturation and ovulation. Methods Thirty normal women and 30 ovulation barrier sterile women were examined by transvaginal ultrasonography, the ovarian artery blood perfusion in ovulatory phase was observed, the parameters including peak systolic velocity ( PSV ),end-diastolic velocity ( EDV ), resistance index ( RI ) and pulsatility index ( PI ) were measured, the results were compared and analyzed. Results In normal women group during ovulatory phase, the ovarian perfusion became more abundant and varied with the follicular development, while in ovulation barrier sterile women group, the ovarian perfusion was always low and RI was obviously high. During the preovulation phase, PSV and EDV in normal group were higher than those in ovulation barrier sterile group ( P0.72 and PI>1.50 for ovulation barrier infertility were 89.5% and 83. 9%. In the normal group, RI and PI of the ovarian artery were similar between the functional ovary and opposite side ovary ( P>0. 05 ). Conclusion Transvaginal color Doppler ultrasonography can analyze the flow indexes of ovarian artery and understand the follicular development and the degree of folliclar maturation, it can provide reliable information for infertility treatment.%目的 探讨排卵期卵巢动脉在卵泡生长成熟和排卵前后的血流动力学变化.方法 应用经阴道彩色多普勒超声对30例正常生育期妇女(正常对照组)和30例排卵障碍患者(排卵障碍组)进行检查,观察排卵周期中卵巢动脉血流灌注情况,包括收缩期峰值流速(PSV)、舒张末期流速(EDV)、阻力指数(RI)、搏动指数(PI),并予以对比分析.结果 整个排卵周期中,正常对照组卵巢动脉血流较丰富且随排卵动态改变;排卵障碍组始终呈现血流纤细、低振幅高阻力表现.在排卵前期,正常对照组PSV、EDV高于排卵障碍组(P0.72、PI>1.50,出现排卵障碍的敏

  13. 三色流式细胞术在小鼠外周血微核检测中的验证%Validation of the Three-color Flow Cytometry Method for Scoring of Micronucleus in Mouse Peripheral Blood

    Institute of Scientific and Technical Information of China (English)

    周长慧; 王庆利; 王征; 张铭; 常艳

    2013-01-01

    A study was performed to validate the three-color flow cytometry-based technique (FCM) for enumerating micronucleus (MN) in mouse peripheral blood and to evaluate the degree of correspondence between FCM and conventional microscopy-based method. For these studies, groups of ten mice received a single dose of solvent (normal saline or 0.5% CMC-Na), benzo[a]pyrene, fluorouracilt methotrexate, mitomycin C, methyl methanesulfonate, colchicine, vincristine sulfate, new compound A or new compound B. Micronucleated reticulocyte frequencies were measured by FCM [20 000 reticulocytes (RET) per sample] while micronucleated polychromatic erythrocytes were scored by conventional microscopy-based analysis [2 000 polychromatic erythrocytes (PCE) per sample]. Parallel analysis of micronucleus induction in peripheral blood by FCM and bone marrow using conventional microscopy-based method showed concordant results (r=0.913). The flow cytometric assessment of MN-RETs in mouse peripheral blood was a sensitive, fast and objective automatic analysis of micronuclei, which could be an acceptable alternative to microscopy-based analysis in mouse bone marrow micronucleus test in vivo.%采用不同作用机制的遗传毒性阳性药和阴性药对三色流式细胞术(FCM)检测小鼠外周血微核(MN)进行方法验证,并与常规人工镜检方法对比.每组10只雄性ICR小鼠,分别单次给予溶剂对照(生理盐水或0.5%羧甲纤维素钠)、苯并芘(BaP)、氟尿嘧啶(5-FU)、甲氨蝶呤(MTX)、丝裂霉素C(MMC)、甲磺酸甲酯(MMS)、秋水仙素(Col)、硫酸长春新碱(Vinc)、新化合物A或新化合物B,检测各组小鼠外周血中20 000个网织红细胞(RET)的MN数,同时采用常规显微镜计数各组小鼠骨髓中2 000个嗜多染红细胞(PCE)的MN数.FCM检测的外周血中MN-RET百分率与常规显微镜观察的骨髓中MN-PCE百分率有良好的相关性(r=0.913).FCM小鼠外周血微核法是一种灵敏、快速、客观的自

  14. Detection on distribution and flowing dynamics of cutaneous perforators of tibial anterior arteries with col-or Doppler flow imaging%彩色多普勒超声对胫前动脉穿支皮瓣血管的研究

    Institute of Scientific and Technical Information of China (English)

    高慧; 胡建群

    2015-01-01

    目的:应用高分辨率的彩色多普勒血流成像( CDFI)对胫前动脉穿支的分布规律及血流动力学参数进行研究。方法应用CDFI对40侧胫前动脉穿支血管的数目、起始内径、走行、分布进行检测。并对穿支穿深筋膜处进行体表标记。应用脉冲多普勒( PW)测量穿支起始处及穿深筋膜处收缩期峰值流速( PSV),建立胫前动脉穿支血流动力学正常对照,并按侧别分组进行统计学分析。结果胫前动脉共40侧,检出穿动脉总数236支,每侧4~8支不等,平均5.9支。穿支沿3个肌间隙分布,集中在小腿中上段,胫前动脉穿支穿深筋膜位置大多集中在距离小腿外踝上15~27 cm(55.5%)。穿支动脉起始处及穿深筋膜处PSV左右侧组间差异无统计学意义( P>0.05)。结论彩色多普勒超声可直观地显示穿支的走行分布、有无变异或缺如,能在体表准确定位,并提供血流动力学定量指标评价血管质量,为皮瓣的设计提供可靠的依据。%Objective To study the distribution rules and its flowing dynamics of perforator vessel of tibial anterior arteries with color Doppler imaging.Methods The quantity, the vascular initial diameter, distribution, the quality of the blood vessel and its flowing dynamics of 40 tibial anterior arteries were measured by CDFI.Marked at surface of the perforator perforating deep fascia.Peak systolic velocity ( PSV) from perforator starting to the deep fascia was measured by Pulse Doppler ( PW) .Establish normal control of the anterior tibial artery perforator blood flow dynamics and adopted statistical analysis by the side of the grouped.Results In altogeth-er, 40 legs studied, 236 cutaneous branches were found.Four to eight branches were found on one specimen and the average number of cutaneous perforators was 5.9.Septocutaneous perforators of the anterior tibial artery followed a reproducible pattern ( septa I, II and

  15. Theoretical aspects of color vision

    Science.gov (United States)

    Wolbarsht, M. L.

    1972-01-01

    The three color receptors of Young-Helmholtz and the opponent colors type of information processing postulated by Hering are both present in the human visual system. This mixture accounts for both the phenomena of color matching or hue discrimination and such perceptual qualities of color as the division of the spectrum into color bands. The functioning of the cells in the visual system, especially within the retina, and the relation of this function to color perception are discussed.

  16. Gestational trophoblastic neoplasia: efficacy of color doppler ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Song, Sun Wha; Jee, Won Hee; Choe, Bo Young; Byun, Jae Young; Choi, Byung Gil; Shinn, Kyung Sub [Catholic Univ. College of Medicine, Seoul (Korea, Republic of)

    1997-04-01

    To evaluate the efficacy of color Doppler ultrasound (US) in the diagnosis of gestational trophoblastic neoplasia (GTN). Intralesional color flows and resistive index (RI) on color Doppler US were prospectively analyzed in 21 consecutive suspected GTN cases. RI of the intralesional artery was investigated on the basis of the presence or absence of mass and metastasis. Correlation between RI of intralesional artery and urinary {beta}-hCG was also investigated. Intralesional color flows were identified in 15 patients with GTN. On operation, intralesional color flows were observed in one of two patients in whom the presence of completely necrotic tissue was confirmed. Intralesional color flows, however, were not detected in four patients who were proved not to be GTN sufferers. Sensitivity, specificity, accuracy, positive and negative predictive values, and accuracy were 100%, 83%, 95%, 94% and 100%, respectively. Significant correlation between RI of the intralesional artery and urinary {beta}-hCG was not established (p=0.49, r=0.19). RI of this artery was not substantially different between groups with and without mass, and between groups with and without metastasis (p=0.32, p=0.82). The current study demonstrates that color Doppler US is a sensitive and useful method for the diagnosis of GTN.

  17. Rapid fluctuations in flow and water-column properties in Asan Bay, Guam: implications for selective resilience of coral reefs in warming seas

    Science.gov (United States)

    Storlazzi, C.D.; Field, M.E.; Cheriton, O.M.; Presto, M.K.; Logan, J.B.

    2013-01-01

    Hydrodynamics and water-column properties were investigated off west-central Guam from July 2007 through January 2008. Rapid fluctuations, on time scales of 10s of min, in currents, temperature, salinity, and acoustic backscatter were observed to occur on sub-diurnal frequencies along more than 2 km of the fore reef but not at the reef crest. During periods characterized by higher sea-surface temperatures (SSTs), weaker wind forcing, smaller ocean surface waves, and greater thermal stratification, rapid decreases in temperature and concurrent rapid increases in salinity and acoustic backscatter coincided with onshore-directed near-bed currents and offshore-directed near-surface currents. During the study, these cool-water events, on average, lasted 2.3 h and decreased the water temperature 0.57 °C, increased the salinity 0.25 PSU, and were two orders of magnitude more prevalent during the summer season than the winter. During the summer season when the average satellite-derived SST anomaly was +0.63 °C, these cooling events, on average, lowered the temperature 1.14 °C along the fore reef but only 0.11 °C along the reef crest. The rapid shifts appear to be the result of internal tidal bores pumping cooler, more saline, higher-backscatter oceanic water from depths >50 m over cross-shore distances of 100 s of m into the warmer, less saline waters at depths of 20 m and shallower. Such internal bores appear to have the potential to buffer shallow coral reefs from predicted increases in SSTs by bringing cool, offshore water to shallow coral environments. These cooling internal bores may also provide additional benefits to offset stress such as supplying food to thermally stressed corals, reducing stress due to ultraviolet radiation and/or low salinity, and delivering coral larvae from deeper reefs not impacted by surface thermal stress. Thus, the presence of internal bores might be an important factor locally in the resilience of select coral reefs facing increased

  18. Rapid South Atlantic spreading changes and coeval vertical motion in surrounding continents: Evidence for temporal changes of pressure-driven upper mantle flow

    DEFF Research Database (Denmark)

    Colli, L.; Stotz, Ingo Leonardo; Bunge, H.P.

    2014-01-01

    the rapid spreading rate changes, on order 10 million years, require significant decoupling of regional plate motion from the large-scale mantle buoyancy distribution through a mechanically weak asthenosphere. Andean topographic growth in late Miocene can explain the most recent South Atlantic spreading...... velocity reduction, arising from increased plate boundary forcing associated with the newly elevated topography. But this mechanism is unlikely to explain the Late Cretaceous/Tertiary spreading variations, as changes in Andean paleoelevation at the time are small. We propose an unsteady pressure...

  19. Colors and contact dermatitis.

    Science.gov (United States)

    Bonamonte, Domenico; Foti, Caterina; Romita, Paolo; Vestita, Michelangelo; Angelini, Gianni

    2014-01-01

    The diagnosis of skin diseases relies on several clinical signs, among which color is of paramount importance. In this review, we consider certain clinical presentations of both eczematous and noneczematous contact dermatitis in which color plays a peculiar role orientating toward the right diagnosis. The conditions that will be discussed include specific clinical-morphologic subtypes of eczematous contact dermatitis, primary melanocytic, and nonmelanocytic contact hyperchromia, black dermographism, contact chemical leukoderma, and others. Based on the physical, chemical, and biologic factors underlying a healthy skin color, the various skin shades drawing a disease picture are thoroughly debated, stressing their etiopathogenic origins and histopathologic aspects.

  20. Rapid isoelectric point determination in a miniaturized preparative separation using jet-dispensed optical pH sensors and micro free-flow electrophoresis.

    Science.gov (United States)

    Herzog, Christin; Beckert, Erik; Nagl, Stefan

    2014-10-01

    Herein, the fabrication, characterization, calibration, and application of integrated microfluidic platforms for fast isoelectric point (pI) determinations via free-flow electrophoresis with integrated inkjet-printed fluorescent pH sensor microstructures are presented. These devices allow one to determine the pI of a biomolecule from a sample mixture with moderately good precision and without addition of markers in typically less than 10 s total separation and analysis time. Polyhydroxyethyl methacrylate (pHEMA) hydrogels were covalently coupled with fluorescein and hydroxypyrene trisulfonic acid (HPTS)-based pH probes. These were piezoelectrically jet-dispensed onto acrylate-modified glass as pH sensor microarrays with a diameter of 300-600 μm and thicknesses of 0.4-2.4 μm with high spatial accuracy. Microchip fabrication and integration of these pH sensor arrays was realized by multistep liquid-phase photolithography from oligoethylene glycol precursors resulting in glass-based microfluidic free-flow isoelectric focusing (μFFIEF) chips with integrated pH observation capabilities. The microchips were characterized with regard to pH sensitivity, response times, photo-, and flow stability. Depending on the sensor matrix, they allowed IEF within a pH range of roughly 5.5-10.5 with good sensitivity and fast response times. These microchips were used for FFIEF of small molecule markers and several protein mixtures with simultaneous monitoring of local pH. This allowed the determination of their pI via multispectral imaging of protein and pH sensor fluorescence without addition of external markers. Obtained pI's were generally in good agreement with known data, demonstrating the applicability of the method for pI determination in micropreparative procedures within a time frame of a few seconds only.

  1. Artificial selection for structural color on butterfly wings and comparison with natural evolution

    OpenAIRE

    Wasik, Bethany R.; Liew, Seng Fatt; Lilien, David A.; Dinwiddie, April J.; Noh, Heeso; Cao, Hui; Monteiro, Antónia

    2014-01-01

    Despite significant efforts to study structural colors in nature, little is known about how such colors and structures evolved in the first place. To address this key question, we performed the first artificial selection (to our knowledge) on a structural color using butterflies. We demonstrated rapid evolution of violet structural color from ultra-violet brown scales in Bicyclus anynana butterflies with only six generations of selection. Furthermore, we identified the structural changes resp...

  2. A new method for colors characterization of colored stainless steel using CIE and Munsell color systems

    Science.gov (United States)

    Ji, Keming; Xue, Yongqiang; Cui, Zixiang

    2015-09-01

    It is important to establish an accurate and comprehensive method of characterizing colors of colored stainless steel and understand the changing mechanism and the regularity of colors for the research, production and application of colored stainless steel. In this work, the method which combines reflectance-wavelength with both CIE and Munsell color systems is studied, the changing regularity of hue, brightness and saturation with increasing coloring potential differences is investigated, and the mechanism of color changing is discussed. The results show that by using this method the colors of colored stainless steel can be accurately and comprehensively characterized; with coloring potential differences and colored film thickness increasing, the peaks and troughs of the reflectance curves in visible region move toward long wave, causing the cyclically changing of hue and brightness; the amplitude of reflectance curves increases, resulting in growing of the saturation; the CIE 1931 coordinate curve of colors counterclockwise and cyclically changes around the equal energy light spot.

  3. Paper-Based RNA Extraction, in Situ Isothermal Amplification, and Lateral Flow Detection for Low-Cost, Rapid Diagnosis of Influenza A (H1N1) from Clinical Specimens.

    Science.gov (United States)

    Rodriguez, Natalia M; Linnes, Jacqueline C; Fan, Andy; Ellenson, Courtney K; Pollock, Nira R; Klapperich, Catherine M

    2015-08-04

    The 2009 Influenza A (H1N1) pandemic disproportionately affected the developing world and highlighted the key inadequacies of traditional diagnostic methods that make them unsuitable for use in resource-limited settings, from expensive equipment and infrastructure requirements to unacceptably long turnaround times. While rapid immunoassay diagnostic tests were much less costly and more context-appropriate, they suffered from drastically low sensitivities and high false negative rates. An accurate, sensitive, and specific molecular diagnostic that is also rapid, low-cost, and independent of laboratory infrastructure is needed for effective point-of-care detection and epidemiological control in these developing regions. We developed a paper-based assay that allows for the extraction and purification of RNA directly from human clinical nasopharyngeal specimens through a poly(ether sulfone) paper matrix, H1N1-specific in situ isothermal amplification directly within the same paper matrix, and immediate visual detection on lateral flow strips. The complete sample-to-answer assay can be performed at the point-of-care in just 45 min, without the need for expensive equipment or laboratory infrastructure, and it has a clinically relevant viral load detection limit of 10(6) copies/mL, offering a 10-fold improvement over current rapid immunoassays.

  4. Shock-induced turbulent flow in baffle systems

    Energy Technology Data Exchange (ETDEWEB)

    Kuhl, A.L. [Lawrence Livermore National Lab., CA (United States); Reichenbach, H. [Fraunhofer-Institut fuer Kurzzeitdynamik - Ernst-Mach-Institut (EMI), Freiburg im Breisgau (Germany)

    1993-07-01

    Experiments are described on shock propagation through 2-D aligned and staggered baffle systems. Flow visualization was provided by shadow and schlieren photography, recorded by the Cranz-Schardin camera. Also single-frame, infinite-fringe, color interferograms were used. Intuition suggests that this is a rather simple 2-D shock diffraction problem. However, flow visualization reveals that the flow rapidly evolved into a complex 3-D turbulent mixing problem. Mushroom-shaped mixing regions blocked the flow into the next baffle orifice. Thus energy was transferred from the directed kinetic energy (induced by the shock) to rotational energy of turbulent mixing, and then dissipated by molecular effects. These processes dramatically dissipate the strength of the shock wave. The experiments provide an excellent test case that could be used to assess the accuracy of computer code calculations of such problems.

  5. Naturally Colored Cotton

    Institute of Scientific and Technical Information of China (English)

    履之

    1994-01-01

    Instead of using dye to color cotton, an Arizona cotton breeder is letting nature do the work. Through crossbreeding, Sally Fox of Natural Cotton Colours in Wickenberg is creating plants that yield fiber in an array

  6. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... about the members of the eye-care team . Consumer warning about the improper use of colored contact ... About the Academy Jobs at the Academy Financial Relationships with Industry Medical Disclaimer Privacy Policy Terms of ...

  7. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... to my eye like a suction cup." Halloween is a popular time for people to use colored ... at Case Western Reserve University in Cleveland. "This is far from the truth." Real People, Real Problems ...

  8. Chemistry, Color, and Art.

    Science.gov (United States)

    Orna, Mary Virginia

    2001-01-01

    Describes pigments and artists' colors from a chronological perspective. Explains how chemical analysis can be used to distinguish the differences between artists' palettes, identify the evolution of art, and lead to restoration of an art work. (Contains 13 references.) (YDS)

  9. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... 000 per violation. "Many of the lenses found online or in beauty salons, novelty shops or in ... de contacto de color Find an Ophthalmologist Advanced Search Ask an Ophthalmologist Browse Answers Free Newsletter Get ...

  10. Colors of the Sky.

    Science.gov (United States)

    Bohren, Craig F.; Fraser, Alistair B.

    1985-01-01

    Explains the physical principles which result in various colors of the sky. Topics addressed include: blueness, mystical properties of water vapor, ozone, fluctuation theory of scattering, variation of purity and brightness, and red sunsets and sunrises. (DH)

  11. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... shop, but 10 hours after she first put in a pair of colored contact lenses, Laura Butler of Parkersburg, W.Va., had "extreme pain in both eyes," she said. "Because I had not ...

  12. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Contact Lenses Without a Prescription Sep. 26, 2013 It started as an impulsive buy from a souvenir ... Can Ruin Vision Eye Makeup Safety In fact, it is illegal to sell colored contact lenses without ...

  13. Facts About Color Blindness

    Science.gov (United States)

    ... perception of its employees, such as graphic design, photography, and food quality inspection. The Farnsworth Lantern Test ... a green chalkboard when yellow chalk is used. Art classes, which require selecting appropriate colors of paint ...

  14. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... like a suction cup." Halloween is a popular time for people to use colored contact lenses to ... wear costume contact lenses for Halloween or any time of year, follow these guidelines: Get an eye ...

  15. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... Hidden Dangers of Buying Decorative Contact Lenses Without a Prescription Leer en Español: Peligros asociados con los ... contacto de color Sep. 26, 2013 It started as an impulsive buy from a souvenir shop, but ...

  16. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... lentes de contacto de color Find an ... Link your website to EyeSmart Embed EyeSmart videos on your website Promotional materials for eye health observances EyeSmart resources are also ...

  17. Food Coloring and Behavior

    OpenAIRE

    J Gordon Millichap

    1994-01-01

    The association between the ingestion of tartrazine synthetic food coloring and behavioral change in children referred for assessment of hyperactivity was investigated at the Royal Children’s Hospital, University of Melbourne, Australia.

  18. Colored Contact Lens Dangers

    Medline Plus

    Full Text Available ... popping touch. But colored contact lenses are popular year-round, not just at Halloween. But few know ... contact lenses for Halloween or any time of year, follow these guidelines: Get an eye exam from ...

  19. A Colorful Equatorial Wonderland

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    @@ Papua New Guinea (PNG) is one of the least visited countries in the world... a last frontier for international travelers. PNG is a colorful equatorial wonderland as well as a living example of human's culture 1000 years ago.

  20. Relighting multiple color textures

    Institute of Scientific and Technical Information of China (English)

    DIAO Chang-yu; LU Dong-ming; LIU Gang

    2005-01-01

    With the development of digital library technology, library books made of paper can be digital released and read, and Endangered Cultural Heritages can be preserved. Traditional library's contents and functions can be greatly enhanced by digital technologies. For these new library objects, the primary key problem is precisely reconstructing their 3D models. When constructing complete 3D models, multiple color texture maps are often necessary. A commonly encountered problem uncounted during fusing of textures from multiple color images is color distortion. Each texture of a single 3D model may be obtained under possibly different lighting conditions and color response of the camera. To remove any visible seam and improve color consistency between the textures while avoiding color distortion, we propose a new efficient algorithm to relight all the texture images globally,spread residual light difference, and recolor each image by homogeneous transformation. A relative illumination model was adopted to obtain the relighting function. We choose lαβ color space with minimal correlation between channels for many natural scenes, for calculating the relighting result. Looking into two overlapped images A and B, we can pairwise relight B into A's luminosity condition in two steps. We first scale B's l channel by the lA/lB ratio of the overlapped region. We can assume A and B are in a same color plane now. Then a homogeneous transformation is applied to B's α and β channels which moves B into A's hue and saturation condition. For multiple overlapped color textures, a patch based weighted global relighting method was proposed to minimize the total color difference. The pairwise relighting method was used between each two overlapped images, and the difference in every overlapped region after relighting was weighted and summed up to construct an energy value. We used Nelder-Mead method to find a minimal energy value and the relighting parameters for every image. After

  1. Rapid cooled lens cell

    Science.gov (United States)

    Stubbs, David M.; Hsu, Ike C.

    1991-12-01

    This paper describes the optomechanical design, thermal analysis, fabrication, and test evaluation processes followed in developing a rapid cooled, infrared lens cell. Thermal analysis was the key engineering discipline exercised in the design phase. The effect of thermal stress on the lens, induced by rapid cooling of the lens cell, was investigated. Features of this lens cell that minimized the thermal stress will be discussed in a dedicated section. The results of thermal analysis on the selected lens cell design and the selection of the flow channel design in the heat exchanger will be discussed. Throughout the paper engineering drawings, illustrations, analytical results, and photographs of actual hardware are presented.

  2. COLOR DOPPLER ULTRASONOGRAPHY APPEARANCES OF RENAL VEIN THROMBOSIS AND ITS DIAGNOSTIC VALUE

    Institute of Scientific and Technical Information of China (English)

    Sheng Cai; Guang-xi Zhong; Jian-chu Li; Yu Xia; Hui-jun Li; Yu-xin Jiang

    2007-01-01

    Objective To evaluate color Doppler ultrasonography (CDU) appearances of renal vein thrombosis (RVT) and its diagnostic value.Methods Ten patients with RVT were analyzed retrospectively. Renal structure, distributions of intrarenal flow signals, echogenicity, and flow fullness in main renal veins were observed with CDU. Resistance index (RI) was recorded from the waveforms of segmental or interlobar renal artery.Results Ten kidneys in nine patients were confirmed to have thrombus within the main renal veins, and one patient was confirmed to have thrombus within the small intrarenal veins. The appearances of the main renal vein thrombosis included full of solid echogenicity or strip echogenicity and complete or partial filling defect within the main renal veins, and absent or a few intrarenal venous flow signals in 70% of kidneys involved. The appearances of intrarenal vein thrombosis included obscure renal structure and no venous flow signal within the involved part of the kidneys. Reverse diastolic flow in the intrarenal artery had only a sensitivity of 36% (4/11) ; in other 7 kidneys without intrarenal arterial reverse diastolic flow, increased RI (mean, 0.84; range, 0.74-0.96) was found.Conclusion CDU is helpful for rapid clinical diagnosis and follow-up of RVT, and therefore can be the first imaging modality of choice for RVT.

  3. Color Laser Microscope

    Science.gov (United States)

    Awamura, D.; Ode, T.; Yonezawa, M.

    1987-04-01

    A color laser microscope utilizing a new color laser imaging system has been developed for the visual inspection of semiconductors. The light source, produced by three lasers (Red; He-Ne, Green; Ar, Blue; He-Cd), is deflected horizontally by an AOD (Acoustic Optical Deflector) and vertically by a vibration mirror. The laser beam is focused in a small spot which is scanned over the sample at high speed. The light reflected back from the sample is reformed to contain linear information by returning to the original vibration mirror. The linear light is guided to the CCD image sensor where it is converted into a video signal. Individual CCD image sensors are used for each of the three R, G, or B color image signals. The confocal optical system with its laser light source yields a color TV monitor image with no flaring and a much sharper resolution than that of the conventional optical microscope. The AOD makes possible a high speed laser scan and a NTSC or PAL TV video signal is produced in real time without any video memory. Since the light source is composed of R, G, and B laser beams, color separation superior to that of white light illumination is achieved. Because of the photometric linearity of the image detector, the R, G, and B outputs of the system are most suitably used for hue analysis. The CCD linear image sensors in the optical system produce no geometrical distortion, and good color registration is available principally. The output signal can be used for high accuracy line width measuring. The many features of the color laser microscope make it ideally suited for the visual inspection of semiconductor processing. A number of these systems have already been installed in such a capacity. The Color Laser Microscope can also be a very useful tool for the fields of material engineering and biotechnology.

  4. Color Blind Affirmative Action

    OpenAIRE

    2003-01-01

    This paper presents a conceptual framework for understanding the consequences of the widespread adoption of race-neutral alternatives' to conventional racial affirmative action policies in college admissions. A simple model of applicant competition with endogenous effort is utilized to show that, in comparison to color-conscious affirmative action, these color-blind alternatives can significantly lower the efficiency of the student selection process in equilibrium. We examine data on matricul...

  5. The Computation of Color

    Science.gov (United States)

    1989-09-01

    patches of random colors, named Mondrians after the twentieth-century Dutch painter Piet Mondrian . In one demon- stration, Land illuminates a Mondrian with...Hsien-Che Lee, for his meticulous reading of thesis drafts, insights into color science, and inspiring collaboration on the " Mondrian -sphere" ex...Heinrich for his es- sential contributions to the " Mondrian -spheres" experiments. Special thanks to Nikos for the hours and hours he spent helping me

  6. Static Filtered Sky Color Constancy

    Directory of Open Access Journals (Sweden)

    Ali Alkhalifah

    2016-05-01

    Full Text Available In Computer Vision, the sky color is used for lighting correction, image color enhancement, horizon alignment, image indexing, and outdoor image classification and in many other applications. In this article, for robust color based sky segmentation and detection, usage of lighting correction for sky color detection is investigated. As such, the impact of color constancy on sky color detection algorithms is evaluated and investigated. The color correction (constancy algorithms used includes Gray-Edge (GE, Gray-World (GW, Max-RGB (MRGB and Shades-of-Gray (SG. The algorithms GE, GW, MRGB, and SG, are tested on the static filtered sky modeling. The static filter is developed in the LAB color space. This evaluation and analysis is essential for detection scenarios, especially, color based object detection in outdoor scenes. From the results, it is concluded that the color constancy before sky color detection using LAB static filters has the potential of improving sky color detection performance. However, the application of the color constancy can impart adverse effects on the detection results. For images, the color constancy algorithms depict a compact and stable representative of the sky chroma loci, however, the sky color locus might have a shifting and deviation in a particular color representation. Since the sky static filters are using the static chromatic values, different results can be obtained by applying color constancy algorithms on various datasets.

  7. Novikov Color Algebra and Tortken Color Algebra%Novikov Color 代数与 Tortken Color 代数

    Institute of Scientific and Technical Information of China (English)

    高秀娟; 徐丽媛

    2016-01-01

    Three concepts of Novikov color algebra,Tortken color algebra and Jordan color algebra were defined,then the relations among three algebras were discussed.We gave the basic properties of Novikov color algebra and Tortken color algebra.Then we proved a Tortken color algebra with an identity element is both associative and color commutative.We also showed how to use Novikov color algebra to construct a Tortken color algebra.%给出 Novikov color 代数、Tortken color 和 Jordan color 代数的定义,并讨论它们之间的关系,证明了有单位元的 Tortken color 代数是结合的,也是 color 交换的。给出 Novikov color 代数和 Tortken color 代数的基本性质以及利用 Novikov color 代数构造 Tortken color代数的方法。

  8. Color planner for designers based on color emotions

    Science.gov (United States)

    Cheng, Ka-Man; Xin, John H.; Taylor, Gail

    2002-06-01

    During the color perception process, an associated feeling or emotion is induced in our brains, and this kind of emotion is termed as 'color emotion.' The researchers in the field of color emotions have put many efforts in quantifying color emotions with the standard color specifications and evaluating the influence of hue, lightness and chroma to the color emotions of human beings. In this study, a color planner was derived according to these findings so that the correlation of color emotions and standard color specifications was clearly indicated. Since people of different nationalities usually have different color emotions as different cultural and traditional backgrounds, the subjects in this study were all native Hong Kong Chinese and the color emotion words were all written in Chinese language in the visual assessments. Through the color planner, the designers from different areas, no matter fashion, graphic, interior or web site etc., can select suitable colors for inducing target color emotions to the customers or product-users since different colors convey different meanings to them. In addition, the designers can enhance the functionality and increase the attractiveness of their designed products by selecting suitable colors.

  9. Luminance contours can gate afterimage colors and 'real' colors

    NARCIS (Netherlands)

    Anstis, S.; Vergeer, M.L.T.; Lier, R.J. van

    2012-01-01

    It has long been known that colored images may elicit afterimages in complementary colors. We have already shown (Van Lier, Vergeer, & Anstis, 2009) that one and the same adapting image may result in different afterimage colors, depending on the test contours presented after the colored image. The c

  10. Color Doppler ultrasonography evaluation of amblyopia

    Directory of Open Access Journals (Sweden)

    Ece Turan-Vural

    2013-07-01

    Full Text Available AIM: To assess the hemodynamic changes in the extraocular orbital vessels of amblyopic patients in comparison with non-amblyopic fellow eyes, using color Doppler ultrasonography(CDU. METHODS: Thirty-six eyes of 18 pediatric patients were included in the study(20 amblyopic, 16 normal. All eyes underwent color Doppler ultrasonography examination of ophthalmic artery, central retinal artery, and posterior ciliary artery. RESULTS: The only differences between the two groups with regard to color Doppler ultrasonography parameters was the significantly lower peak systolic velocity(32.70±11.60 vs 55.01±11.68, P=0.001and end-diastolic velocity(6.83±1.91 vs 13.99±4.15, P=0.001for ophthalmic artery in amblyopic eyes.CONCLUSION: Our study showed amblyopic eyes may present a decrease in retrobulbar blood flow velocity.

  11. Color measurement and discrimination

    Science.gov (United States)

    Wandell, B. A.

    1985-01-01

    Theories of color measurement attempt to provide a quantative means for predicting whether two lights will be discriminable to an average observer. All color measurement theories can be characterized as follows: suppose lights a and b evoke responses from three color channels characterized as vectors, v(a) and v(b); the vector difference v(a) - v(b) corresponds to a set of channel responses that would be generated by some real light, call it *. According to theory a and b will be discriminable when * is detectable. A detailed development and test of the classic color measurement approach are reported. In the absence of a luminance component in the test stimuli, a and b, the theory holds well. In the presence of a luminance component, the theory is clearly false. When a luminance component is present discrimination judgements depend largely on whether the lights being discriminated fall in separate, categorical regions of color space. The results suggest that sensory estimation of surface color uses different methods, and the choice of method depends upon properties of the image. When there is significant luminance variation a categorical method is used, while in the absence of significant luminance variation judgments are continuous and consistant with the measurement approach.

  12. 彩色多普勒血流显像结合定量分析技术评价肾血流灌注的临床研究%Clinical study on renal flow perfusion using color Doppler flow imaging combined with quantitative analysis technique

    Institute of Scientific and Technical Information of China (English)

    李薇玢; 林铤; 张艳容; 吕清; 王新房; 谢明星; 项飞翔; 陈玉媛; 刘莹莹; 郭美荣

    2009-01-01

    Objective To explore the clinical value of color Doppler flow imaging(CDFI) combined with quantitative analysis technique to evaluate renal flow perflusion. Methods Twenty patients with different renal diseases matched with healthy control subjects were examined with Philips iU22 CDFI system. CDFI system and Qlab quantitative technique were used to measure renal restrictive index(RI), vascularization index(VI), flow index(FI), vascularization-flow index (VFI). The patients all received renal single-photon emission computed tomography (SPECT) examination. Results The RI of 32 kidney with lower flow perfusion in SPECT were higher than in the contol group (P <0.01). VI,FI, VFI were lower than those in control(VI, VFI, P <0.01 ;FI, P <0.05). Conelusious The renal blood flow perfusion of patients with renal diseases are lower than that of healthy people. It has high clinical value using CDFI combined with quantitative analysis technique to evaluate the renal perfusion of the patients with renal diseases.%目的 探讨彩色多普勒血流显像结合血流定量分析技术评价肾血流灌注的临床意义.方法 采用Philips iU22彩色多普勒血流显像结合血流定量分析技术分别测量20例正常对照者和20例肾疾病患者的肾叶间动脉、小叶间动脉阻力指数(RI)、血管指数(VI)、血流指数(FI)、血管-血流指数(VFI),并进行比较分析.所有肾疾病患者均于彩色多普勒显像前后进行放射性核素肾动态扫描.结果 20例肾疾病患者单光子发射计算机断层显像检查(SPECT)显示血流灌注减少的32只肾叶间动脉、小叶间动脉RI值明显高于正常对照组(P<0.01),VI、FI、VFI值均明显低于正常对照组(VI,VFI,P<0.01;FI,P<0.05).结论 肾疾病患者的肾血流灌注显著低于正常对照组,利用彩色多普勒血流显像结合血流定量分析技术可以无创性定量评价肾血流灌注.

  13. Comparison of Color Model in Cotton Image Under Conditions of Natural Light

    Science.gov (United States)

    Zhang, J. H.; Kong, F. T.; Wu, J. Z.; Wang, S. W.; Liu, J. J.; Zhao, P.

    Although the color images contain a large amount of information reflecting the species characteristics, different color models also get different information. The selection of color models is the key to separating crops from background effectively and rapidly. Taking the cotton images collected under natural light as the object, we convert the color components of RGB color model, HSL color model and YIQ color model respectively. Then, we use subjective evaluation and objective evaluation methods, evaluating the 9 color components of conversion. It is concluded that the Q component of the soil, straw and plastic film region gray values remain the same without larger fluctuation when using subjective evaluation method. In the objective evaluation, we use the variance method, average gradient method, gray prediction objective evaluation error statistics method and information entropy method respectively to find the minimum numerical of Q color component suitable for background segmentation.

  14. Can grapheme-color synesthesia be induced by hypnosis?

    Science.gov (United States)

    Anderson, Hazel P; Seth, Anil K; Dienes, Zoltan; Ward, Jamie

    2014-01-01

    Grapheme-color synesthesia is a perceptual experience where graphemes, letters or words evoke a specific color, which are experienced either as spatially coincident with the grapheme inducer (projector sub-type) or elsewhere, perhaps without a definite spatial location (associator sub-type). Here, we address the question of whether synesthesia can be rapidly produced using a hypnotic color suggestion to examine the possibility of "hypnotic synesthesia", i.e., subjectively experienced color hallucinations similar to those experienced by projector synesthetes. We assess the efficacy of this intervention using an "embedded figures" test, in which participants are required to detect a shape (e.g., a square) composed of local graphemic elements. For grapheme-color synesthetes, better performance on the task has been linked to a higher proportion of graphemes perceived as colored. We found no performance benefits on this test when using a hypnotic suggestion, as compared to a no-suggestion control condition. The same result was found when participants were separated according to the degree to which they were susceptible to the suggestion (number of colored trials perceived). However, we found a relationship between accuracy and subjective reports of color in those participants who reported a large proportion of colored trials: trials in which the embedded figure was accurately recognized (relative to trials in which it was not) were associated with reports of more intense colors occupying a greater spatial extent. Collectively, this implies that hypnotic color was only perceived after shape detection rather than aiding in shape detection via color-based perceptual grouping. The results suggest that hypnotically induced colors are not directly comparable to synesthetic ones.

  15. Size characterization of barley starch granules by gravitational field-flow fractionation: a rapid, low-cost method to assess the brewing capability of different strains.

    Science.gov (United States)

    Reschiglian, Pierluigi; Zattoni, Andrea; Casolari, Sonia; Krumlova, Andrea; Budinska, Marcela; Chmelík, Josef

    2002-04-01

    Cereal starch occurs as two types of micrometer-sized granules, large and small. Large starch granules are more susceptible to enzymatic hydrolysis. When cereal starch is used for fermentation processes, as in brewing of barley malt, the barley strains with the highest content of large starch granules should be preferred. Gravitational field-flow fractionation (GFFF) is a separation method able to fractionate starch samples at low cost and short analysis time. In this work, the search for the best GFFF conditions for the analytical separation of barley starch within an inter-laboratory approach is presented. For different barley strains cultivated under monitored conditions the size distributions of starch granules is here quickly monitored and characterized by GFFF. As a consequence, dimensional characterization of barley starch can allow for the selection of the most suitable strains with the lowest content of non-degradable starch.

  16. Color change, phenotypic plasticity, and camouflage

    Directory of Open Access Journals (Sweden)

    Martin eStevens

    2016-05-01

    Full Text Available The ability to change appearance over a range of timescales is widespread in nature, existing in many invertebrate and vertebrate groups. This can include color change occurring in seconds, minutes, and hours, to longer term changes associated with phenotypic plasticity and development. A major function is for camouflage against predators because color change and plasticity enables animals to match their surroundings and potentially reduce the risk of predation. Recently, we published findings (Stevens et al. 2014a showing how shore crabs can change their appearance and better match the background to predator vision in the short term. This, coupled with a number of past studies, emphasizes the potential that animals have to modify their appearance for camouflage. However, the majority of studies on camouflage and color plasticity have focused on a small number of species capable of unusually rapid changes. There are many broad questions that remain about the nature, mechanisms, evolution, and adaptive value of color change and plasticity for concealment. Here, I discuss past work and outline six questions relating to color change and plasticity, as well as major avenues for future work.

  17. Color speckle in laser displays

    Science.gov (United States)

    Kuroda, Kazuo

    2015-07-01

    At the beginning of this century, lighting technology has been shifted from discharge lamps, fluorescent lamps and electric bulbs to solid-state lighting. Current solid-state lighting is based on the light emitting diodes (LED) technology, but the laser lighting technology is developing rapidly, such as, laser cinema projectors, laser TVs, laser head-up displays, laser head mounted displays, and laser headlamps for motor vehicles. One of the main issues of laser displays is the reduction of speckle noise1). For the monochromatic laser light, speckle is random interference pattern on the image plane (retina for human observer). For laser displays, RGB (red-green-blue) lasers form speckle patterns independently, which results in random distribution of chromaticity, called color speckle2).

  18. Detection of P-glycoprotein with a rapid flow cytometric functional assay using Fluo-3: evaluation of sensitivity, specificity and feasibility in multiparametric analysis.

    Science.gov (United States)

    Van Acker, K L; De Greef, C; Eggermont, J; Zhang, P; Vandenberghe, P; Boogaerts, M A

    1995-08-01

    The specificity and sensitivity of a flow cytometric assay simultaneously measuring expression and transport function of the multidrug resistance associated P-glycoprotein (Pgp) was evaluated. The monoclonal antibody (mAb), MRK16 was used to detect phenotypic Pgp expression while Fluo-3-AM was used as a fluorescent substrate in a Pgp functional transport assay. The specificity of the functional assay was examined in two vinblastine selected human leukemic cell lines (K562/VLB2.5 and CCRF-CEM/VLB50) with acquired Pgp overexpression. Downmodulation of Pgp function in these cell lines could be demonstrated with different substances (verapamil, vinblastine, trifluoperazine, cyclosporin A, progesterone and quinidine) and was proven to be consistently higher in the vinblastine selected cells than in their non-selected drug sensitive counterparts. Unexpectedly, modulator activity was also observed in drug sensitive K562 and CCRF-CEM cell lines despite the inability to detect Pgp in those cells by MRK16 flow cytometrically. Low level expression of the MDR1 gene encoding Pgp in sensitive K562 cells was however demonstrated with a sensitive RT-PCR procedure. The small effect of Pgp modulators in non-drug selected cells could therefore be attributed to low level basal expression of Pgp and illustrates the sensitivity of the functional assay. Also, the effect of various Pgp modulators on Pgp function was more pronounced in a subpopulation of Pgp expressing lymphocytes than in lymphocytes which did not express Pgp. Finally, a correlation was found between discrete variations in Pgp expression and Pgp function of CD4+ lymphocytes, underscoring the feasibility of the functional assay in a triple parametric procedure. The triple parametric assay holds promise to detect Pgp expression and function in clinical samples containing mixtures of malignant and non-malignant cells.

  19. Lateral flow assay for rapid differentiation of Mycobacterium tuberculosis complex and 97 species of mycobacteria other than tuberculosis grown in Löwenstein-Jensen and TK-SLC medium

    Directory of Open Access Journals (Sweden)

    Akyar I

    2010-01-01

    Full Text Available Background: Mycobacterial antigen MPB64 is a secretory protein specific for Mycobacterium tuberculosis complex. A lateral flow immunochromatographic assay (ICA is a method used for the rapid differentiation of M. tuberculosis complex. Aim: We aimed to evaluate the performance of ICA in rapid differentiation of M. tuberculosis complex from 97 Mycobacterium species other than tuberculosis (MOTT, which are grown in Lφwenstein-Jensen and TK-selective (SLC medium. Materials and Methods: The study was performed in our laboratory between January 2009 and January 2010. A total of 394 isolates consisting of reference strains of 34 M. tuberculosis from World Health Organization (WHO collection, 97 different MOTT bacilli, 7 Mycobacterium bovis BCG substrains and total 256 clinical Mycobacterium isolates were tested by ICA, which is based on anti-MPB64 monoclonal antibodies. All the strains were inoculated onto a TK-SLC (selective medium and Lφwenstein-Jensen medium. TK-SLC is a new rapid mycobacterial culture medium that indicates mycobacterial growth by colour change. Results: The growth of mycobacterial strains was observed in 10-12 days on TK-SLC medium. ICA test was performed in 15 minutes. All strains belonging to M. tuberculosis complex group were found positive and all MOTT species were found negative on ICA slides. The results were confirmed with nucleic acid amplification by polymerase chain reaction (PCR using primers specific for M. tuberculosis complex. Conclusion: With the additive effect of growth on TK-SLC medium in 10-12 days, the mycobacterial antigen MPB64 is a very useful and specific tool in rapid differentiation of M. tuberculosis and MOTT grown in culture.

  20. Rapid discrimination of Gram-positive and Gram-negative bacteria in liquid samples by using NaOH-sodium dodecyl sulfate solution and flow cytometry.

    Directory of Open Access Journals (Sweden)

    Atsushi Wada

    Full Text Available BACKGROUND: For precise diagnosis of urinary tract infections (UTI, and selection of the appropriate prescriptions for their treatment, we explored a simple and rapid method of discriminating gram-positive and gram-negative bacteria in liquid samples. METHODOLOGY/PRINCIPAL FINDINGS: We employed the NaOH-sodium dodecyl sulfate (SDS solution conventionally used for plasmid extraction from Escherichia coli and the automated urine particle analyzer UF-1000i (Sysmex Corporation for our novel method. The NaOH-SDS solution was used to determine differences in the cell wall structures between gram-positive and gram-negative bacteria, since the tolerance to such chemicals reflects the thickness and structural differences of bacterial cell walls. The UF-1000i instrument was used as a quantitative bacterial counter. We found that gram-negative bacteria, including E. coli, in liquid culture could easily be lysed by direct addition of equal volumes of NaOH-SDS solution. In contrast, Enterococcus faecalis, which is a gram-positive bacterium, could not be completely lysed by the solution. We then optimized the reaction time of the NaOH-SDS treatment at room temperature by using 3 gram-positive and 4 gram-negative bacterial strains and determined that the optimum reaction time was 5 min. Finally, in order to evaluate the generalizability of this method, we treated 8 gram-positive strains and 8 gram-negative strains, or 4 gram-positive and 4 gram-negative strains incubated in voluntary urine from healthy volunteers in the same way and demonstrated that all the gram-positive bacteria were discriminated quantitatively from gram negative bacteria using this method. CONCLUSIONS/SIGNIFICANCE: Using our new method, we could easily discriminate gram-positive and gram-negative bacteria in liquid culture media within 10 min. This simple and rapid method may be useful for determining the treatment course of patients with UTIs, especially for those without a prior history

  1. Estudo dopplerfluxométrico das artérias uterinas antes e após inserção do DIU Color doppler flow analysis of the uterine arteries before and after DIU insertion

    Directory of Open Access Journals (Sweden)

    Marco Aurélio Martins de Souza

    2004-06-01

    Full Text Available OBJETIVO: averiguar se ocorrem alterações nos parâmetros da dopplervelocimetria em usuárias do dispositivo intra-uterino (DIU T cobre 380, por meio do estudo das artérias uterinas antes e depois da inserção do DIU em mulheres lactantes e não lactantes. MÉTODOS: ensaio clínico prospectivo, analítico, com 100 pacientes, em que avaliamos à dopplervelocimetria: índice de resistência (IR, índice de pulsatilidade (IP e relação sístole/diástole (SD. As pacientes selecionadas foram submetidas à avaliação pré-inserção do DIU e a novos exames pós-inserção, realizados com 30 dias (um ciclo e com 90 dias (três ciclos. RESULTADOS: os valores obtidos nas artérias uterinas no grupo antes da inserção do DIU foram de 0,9 para o IR, de 2,4 para o IP e de 10,0 para a relação SD. Os valores 30 dias após a inserção do DIU foram de 0,9 para o IR, de 2,5 para o IP e de 10,7 para a relação SD. Após três ciclos aferimos um valor de 0,9 para o IR, de 2,5 para o IP e de 10,7 para a relação SD. A comparação dos resultados obtidos antes e depois da inserção do DIU mostrou valor p de 0,51 para o IR, de 0,37 para o IP e de 0,51 para a relação SD, demonstrando que após a inserção, não houve modificações significativas na dopplervelocimetria. CONCLUSÕES: o uso do DIU T cobre 380 não tem efeito nos índices de dopplervelocimetria das artérias uterinas tanto em pacientes amamentando ou não.OBJECTIVE: to observe if there is any alteration in the Dopplervelocimetry of the uterine arteries of nursing and not nursing women after the insertion of the copper T 380 intrauterine device (IUD. METHODS: prospective, analytical, self-paired clinical assay, with 100 patients in whom we evaluated the color doppler flow: resistance index (RI, pulsative index (PI and systole/diastole (SD ratio. Nursing and not nursing women were assessed before IUD insertion as well as 30 days (one cycle and 90 days (three cycles after the insertion

  2. Color measurement of methylene blue dye/clay mixtures and its application using economical methods

    Science.gov (United States)

    Milosevic, Maja; Kaludjerovic, Lazar; Logar, Mihovil

    2016-04-01

    Identifying the clay mineral components of clay materials by staining tests is rapid and simple, but their applicability is restricted because of the mutual interference of the common components of clay materials and difficulties in color determination. The change of color with concentration of the dye is related to the use of colorants as a field test for identifying clay minerals and has been improved over the years to assure the accuracy of the tests (Faust G. T., 1940). The problem of measurement and standardization of color may be solved by combination of colors observed in staining tests with prepared charts of color chips available in the Munsell Book of Color, published by Munsell Color Co. Under a particular set of illumination conditions, a human eye can achieve an approximate match between the color of the dyed clay sample and that of a standard color chip, even though they do have different spectral reflectance characteristics. Experiments were carried out with diffuse reflectance spectroscopy on selected clay samples (three montmorillonite, three kaolinite and one mix-layer clay samples) saturated with different concentration of methylene blue dye solution. Dominant wavelength and purity of the color was obtained on oriented dry samples and calculated by use of the I. C. I. (x, y) - diagram in the region of 400-700 nm (reflectance spectra) without MB and after saturation with different concentrations of MB solutions. Samples were carefully photographed in the natural light environment and processed with user friendly and easily accessible applications (Adobe color CC and ColorHexa encyclopedia) available for android phones or tablets. Obtained colors were compared with Munsell standard color chips, RGB and Hexa color standards. Changes in the color of clay samples in their interaction with different concentration of the applied dye together with application of economical methods can still be used as a rapid fieldwork test. Different types of clay

  3. Photoproduction of events with rapidity gaps between jets with ZEUS at HERA

    Energy Technology Data Exchange (ETDEWEB)

    Ryan, P.D.

    2006-11-15

    Cross sections for the photoproduction of dijet events, where the two jets with the highest transverse energy are separated by a large gap in pseudorapidity, have been studied with the ZEUS detector using an integrated luminosity of 38.6 pb{sup -1}. Rapidity-gap events are defined in terms of the energy flow between the jets, such that the total summed transverse energy in this region is less than some value E{sup CUT}{sub T}. The data show a clear excess above the predictions of standard photoproduction models. Models which include color-singlet exchange are able to describe the data. (orig.)

  4. Color Addition and Subtraction Apps

    Science.gov (United States)

    Ruiz, Frances; Ruiz, Michael J.

    2015-10-01

    Color addition and subtraction apps in HTML5 have been developed for students as an online hands-on experience so that they can more easily master principles introduced through traditional classroom demonstrations. The evolution of the additive RGB color model is traced through the early IBM color adapters so that students can proceed step by step in understanding mathematical representations of RGB color. Finally, color addition and subtraction are presented for the X11 colors from web design to illustrate yet another real-life application of color mixing.

  5. Rapid screening of the heterogeneity of DNA methylation by single-strand conformation polymorphism and CE-LIF in the presence of electro-osmotic flow.

    Science.gov (United States)

    Yu, Meng-Hsuan; Huang, Ya-Chi; Chang, Po-Ling

    2014-08-01

    DNA methylation is a complex event in epigenetic studies because of both the large CpG islands present upstream of the promoter region and the different distribution of DNA methylation despite similar methylation levels. For this reason, we proposed a fast, cost-effective method for the screening of DNA methylation based on SSCP and CE-LIF. In this study, the PCR products that were amplified from bisulfite-treated genomic DNA were denatured at 94°C, followed by immediate chilling in ice water to form the ssDNA. The ssDNA were separated by 1.5% poly(ethylene oxide) (Mavg 8 000 000 Da) in the presence of EOF according to the different conformations represented by their unique methylation states. This result demonstrated that four hepatocellular carcinoma cell lines represented a different heterogeneity of DNA methylation and could be distinguished by SSCP-CE. The results obtained from SSCP-CE also corresponded with those obtained from combined bisulfide restriction analysis and methylation-sensitive high-resolution melting analysis. Therefore, the proposed SSCP-CE method may potentially be used for rapid screening for determination of the heterogeneity of DNA methylation in further epigenetic studies and clinical diagnosis.

  6. Preparation of low flow-resistant methacrylate-based monolithic stationary phases of different hydrophobicity and the application to rapid reversed-phase liquid chromatographic separation of alkylbenzenes at high flow rate and elevated temperature.

    Science.gov (United States)

    Ueki, Yuji; Umemura, Tomonari; Iwashita, Yoshikazu; Odake, Tamao; Haraguchi, Hiroki; Tsunoda, Kin-ichi

    2006-02-17

    Low flow-resistant alkyl methacrylate-based monolithic stationary phases of different hydrophobicity were constructed for reversed-phase capillary liquid chromatography by thermally initiated radical polymerization of respective methacrylate ester monomer with different alkyl chain (C2, C4, C6, C12, C18) and ethylene glycol dimethacrylate (EDMA) in a 250 microm i.d. fused silica capillary. The hydrophobicity was basically controlled by changing the length and/or the density of the alkyl-chain, while the composition and the ratio of porogenic solvent were adjusted to obtain highly permeable rigid monoliths with adequate column efficiency. Among the prepared monolithic stationary phases, C18-methacrylate monoliths polymerized from a binary porogenic solvent of isoamyl alcohol and 1,4-buthandiol exhibited the most promising performance in terms of hydraulic resistance and column efficiency. The pressure drops of 20-cm long monolithic columns were below approximately 0.4 MPa at a normal linear velocity of 1mm/s (a flow rate of 3 microL/min), and the numbers of theoretical plates for alkylbenzenes mostly exceeded 3000 plates/20 cm. The produced monolithic columns had good mechanical strength for high pressure and temperature, and could be properly operated even at a temperature of 80 degrees C and at a pressure of at least 33 MPa. At 80 degrees C, the theoretical plate numbers reached 6000 plates/20 cm because of the enhanced mass transfer. Due to the novel hydraulic resistance and mechanical strength, the separation time could be reduced 120-fold simply by raising the flow rate and column temperature.

  7. Rapid, highly efficient extraction and purification of membrane proteins using a microfluidic continuous-flow based aqueous two-phase system.

    Science.gov (United States)

    Hu, Rui; Feng, Xiaojun; Chen, Pu; Fu, Meng; Chen, Hong; Guo, Lin; Liu, Bi-Feng

    2011-01-07

    Membrane proteins play essential roles in regulating various fundamental cellular functions. To investigate membrane proteins, extraction and purification are usually prerequisite steps. Here, we demonstrated a microfluidic aqueous PEG/detergent two-phase system for the purification of membrane proteins from crude cell extract, which replaced the conventional discontinuous agitation method with continuous extraction in laminar flows, resulting in significantly increased extraction speed and efficiency. To evaluate this system, different separation and detection methods were used to identify the purified proteins, such as capillary electrophoresis, SDS-PAGE and nano-HPLC-MS/MS. Swiss-Prot database with Mascot search engine was used to search for membrane proteins from random selected bands of SDS-PAGE. Results indicated that efficient purification of membrane proteins can be achieved within 5-7s and approximately 90% of the purified proteins were membrane proteins (the highest extraction efficiency reported up to date), including membrane-associated proteins and integral membrane proteins with multiple transmembrane domains. Compared to conventional approaches, this new method had advantages of greater specific surface area, minimal emulsification, reduced sample consumption and analysis time. We expect the developed method to be potentially useful in membrane protein purifications, facilitating the investigation of membrane proteomics.

  8. Artificial color perception using microwaves

    CERN Document Server

    Choudhury, Debesh

    2013-01-01

    We report the feasibility of artificial color perception under microwave illumination using a standard microwave source and an antenna. We have sensed transmitted microwave power through color objects and have distinguished the colors by analyzing the sensed transmitted power. Experiments are carried out using a Gunn diode as the microwave source, some colored liquids as the objects and a microwave diode as the detector. Results are presented which open up an unusual but new way of perceiving colors using microwaves.

  9. Precision of Synesthetic Color Matching Resembles That for Recollected Colors Rather than Physical Colors

    Science.gov (United States)

    Arnold, Derek H.; Wegener, Signy V.; Brown, Francesca; Mattingley, Jason B.

    2012-01-01

    Grapheme-color synesthesia is an atypical condition in which individuals experience sensations of color when reading printed graphemes such as letters and digits. For some grapheme-color synesthetes, seeing a printed grapheme triggers a sensation of color, but "hearing" the name of a grapheme does not. This dissociation allowed us to…

  10. Precision of Synesthetic Color Matching Resembles That for Recollected Colors Rather than Physical Colors

    Science.gov (United States)

    Arnold, Derek H.; Wegener, Signy V.; Brown, Francesca; Mattingley, Jason B.

    2012-01-01

    Grapheme-color synesthesia is an atypical condition in which individuals experience sensations of color when reading printed graphemes such as letters and digits. For some grapheme-color synesthetes, seeing a printed grapheme triggers a sensation of color, but "hearing" the name of a grapheme does not. This dissociation allowed us to…

  11. Color Memory of University Students: Influence of Color Experience and Color Characteristic

    Science.gov (United States)

    Bynum, Carlisle; Epps, Helen H.; Kaya, Naz

    2006-01-01

    The ability to select a previously viewed color specimen from an array of specimens that differ in hue, value, or chroma varies among individuals, and may be related to one's basic color discrimination ability or to prior experience with color. This study investigated short-term color memory of 40 college students, 20 of whom were interior design…

  12. The color "fruit": object memories defined by color.

    Science.gov (United States)

    Lewis, David E; Pearson, Joel; Khuu, Sieu K

    2013-01-01

    Most fruits and other highly color-diagnostic objects have color as a central aspect of their identity, which can facilitate detection and visual recognition. It has been theorized that there may be a large amount of overlap between the neural representations of these objects and processing involved in color perception. In accordance with this theory we sought to determine if the recognition of highly color diagnostic fruit objects could be facilitated by the visual presentation of their known color associates. In two experiments we show that color associate priming is possible, but contingent upon multiple factors. Color priming was found to be maximally effective for the most highly color diagnostic fruits, when low spatial-frequency information was present in the image, and when determination of the object's specific identity, not merely its category, was required. These data illustrate the importance of color for determining the identity of certain objects, and support the theory that object knowledge involves sensory specific systems.

  13. Clinical value of the placental abruption diagnosed by color Doppler ultrasonic combining with enhancement Doppler E-flow imaging%彩色多普勒超声结合增强型能量多普勒成像诊断胎盘早剥的临床价值探讨

    Institute of Scientific and Technical Information of China (English)

    魏达友; 梁玉婷; 蔡永秋; 巫朝君; 刘思怡; 吴绍锋

    2008-01-01

    目的 探讨彩色多普勒超声结合增强型能量多普勒(E-Flow)成像诊断胎盘早剥,尤其是轻型胎盘早剥的声像图特点,为临床提供有效的诊断依据.方法 应用彩色多普勒超声结合E-Flow对50例重型胎盘早剥、23例轻型胎盘早剥的声像图及临床结局进行分析研究.结果 50例重型胎盘早剥的彩色多普勒超声结合E-Flow的诊断与临床及产后病理诊断相符,诊断符合率100%;23例轻型胎盘早剥的彩色多普勒超声结合E-Flow的诊断与临床及产后病理诊断符合19例,诊断符合率83%,漏诊、误诊4例(17%).73例胎盘早剥患者中剖宫产60例,阴道分娩13例.结论 增强型能量多普勒超声结合彩色多普勒超声成像技术对重型胎盘早剥的诊断准确率高,为轻型胎盘早剥的诊断提供了新手段,并能动态监测轻型胎盘早剥的转归.%Objective To explore the ultrasonographical characteristics of placental abruption, especially the light placental abruption that was diagnosed by color Doppler ultrasonic combining with enhancement Doppler E-flow imaging, providing diagnosis data for clinical treatment. Methods With color Doppler ultrasonic and enhancement Doppler E-flow imaging, an analysis was made on the ultrasonography and clinical result of 50 patients with heavy placental abruption and 23 patients with light placental abruption. Results The diagnosis and clinical treatment of 50 patients with heavy placental abruption who had been diagnosed by color Doppler ultrasonic combining with enhancement Doppler E-flow imaging were in conformity with the postnatal pathological diagnosis. The coincidence rate in diagnosis was 100%. Of 23 patients with light placental abruption who had been diagnosed by color Doppler ultrasonic combining with enhancement E-flow Doppler imaging, 19 cases' diagnosis and clinical treatment were in accordance with their postnatal pathological diagnosis and the coincidence rate was 83%, 4 cases were

  14. Color control of the multi-color printing device

    Institute of Scientific and Technical Information of China (English)

    WANG Xiao-hua; XIU Xiao-jie; ZHU Wen-hua; TANG Hong-jun

    2006-01-01

    Conventional color-printing systems often use inks of three hues, such as CMY, CMYK and CMYKLcLm, but in order to obtain more realistic color reproductions, the ink set of more than three hues has been adopted by some color-printing systems. It is difficult, however, to model the composed color with the multiple inks when the number of the output ink hues exceeds three due to the none-unique mapping between the color spaces of the CIE Lab and the multi-color printing device. In this paper, we propose a fine color-printing method for multi-color printing device with the ink set of more than three hues. The proposed approach has good color expression ability and provides fine control of the printed color. By dividing the output color space into several subspaces, our method allows one-to-one mapping between the standard color space and the multi-color output color space. It has been proved effective when applied to the digital inkjet printer-Mutoh8000.

  15. 200GeV AuAu碰撞中前快度区的微分椭圆流%Differential Elliptic Flow at Forward Rapidity in 200GeV AuAu Collisions

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Identified particle elliptic flow results are presented for the Au+Au reaction at (√SNN) = 200GeV as a function of transverse momentum and pseudorapidity. Data at pseudorapidities η≈ 0, 1, and 3.4 were obtained using the two BRAHMS spectrometers. Differential v2(η, pt) values for a given particle type are found to be essentially constant over the covered pseudorapidity range, in contrast to the integral v2 values which have previously been observed to decrease at forward rapidities. A softening of the particle spectra at forward angles is found to account for at least part of the integral v2 falloff. The data are found to be consistent with existing constituent quark scaling systematics.

  16. Full-Spectrum Flexible Color Printing at the Diffraction Limit

    CERN Document Server

    Richner, Patrizia; Lendenmann, Tobias; Kress, Stephan J P; Kim, David K; Norris, David J; Poulikakos, Dimos

    2016-01-01

    Color printing at the diffraction limit has been recently explored by fabricating nanoscale plasmonic structures with electron beam lithography. However, only a limited color range and constant intensity throughout the structure have been demonstrated. Here we show an alternative, facile approach relying on the direct, open-atmosphere electrohydrodynamic rapid nanodrip printing of controlled amounts of red, green and blue (RGB) quantum dots at a resolution of 250 nm. The narrow emission spectrum of the dots allows the coverage of a very broad color space, exceeding standard RGB (sRGB) of modern display devices. We print color gradients of variable intensity, which to date could not be achieved with diffraction-limited resolution. Showcasing the capabilities of the technology, we present a photo-realistic printed image of a colorful parrot with a pixel size of 250 nm.

  17. 流式细胞技术快速检测果汁中的霉菌、酵母菌%Study on a flow cytometry method in rapid detection of mold and yeast in fruit juice

    Institute of Scientific and Technical Information of China (English)

    刘道亮; 胡连霞; 赵占民; 张峻峰; 孙晓霞

    2011-01-01

    A flow cytometry method which can rapidly detect mold and yeast in fruit juice with pulp was studied.The sample was pretreated to remove matrix particles affecting the reliability of FCM detection using membrane filtration and centrifugation techniques.Therefore the FCM detection limit of mold and yeast in fruit juice samples reached 101cfu/mL magnitude,and the detection time was greatly shortened from 5 days to 100min.The standard curves showed that FCM detection results were linear correlation with those of standard plate count method.Thus FCM was a kind of more rapid and accurate new method.%研究应用流式细胞技术(flow cytometry,FCM)快速检测果汁饮料中霉菌、酵母菌的方法。通过正交实验和方差分析,对样品前处理技术条件进行优化,去除了影响FCM检测的基质颗粒,使FCM检测限达到101cfu/mL数量级,检测时间从5d缩短到100min。从绘制的标准曲线可以看出,FCM与平板法线性相关,符合性好。FCM将以更加灵敏、准确、快速、操作简便的优点成为一种可替代平板法来检测果汁中霉菌、酵母菌的自动化仪器检测新技术。

  18. The biology of color.

    Science.gov (United States)

    Cuthill, Innes C; Allen, William L; Arbuckle, Kevin; Caspers, Barbara; Chaplin, George; Hauber, Mark E; Hill, Geoffrey E; Jablonski, Nina G; Jiggins, Chris D; Kelber, Almut; Mappes, Johanna; Marshall, Justin; Merrill, Richard; Osorio, Daniel; Prum, Richard; Roberts, Nicholas W; Roulin, Alexandre; Rowland, Hannah M; Sherratt, Thomas N; Skelhorn, John; Speed, Michael P; Stevens, Martin; Stoddard, Mary Caswell; Stuart-Fox, Devi; Talas, Laszlo; Tibbetts, Elizabeth; Caro, Tim

    2017-08-04

    Coloration mediates the relationship between an organism and its environment in important ways, including social signaling, antipredator defenses, parasitic exploitation, thermoregulation, and protection from ultraviolet light, microbes, and abrasion. Methodological breakthroughs are accelerating knowledge of the processes underlying both the production of animal coloration and its perception, experiments are advancing understanding of mechanism and function, and measurements of color collected noninvasively and at a global scale are opening windows to evolutionary dynamics more generally. Here we provide a roadmap of these advances and identify hitherto unrecognized challenges for this multi- and interdisciplinary field. Copyright © 2017 The Authors, some rights reserved; exclusive licensee American Association for the Advancement of Science. No claim to original U.S. Government Works.

  19. Mechanisms and behavioural functions of structural coloration in cephalopods

    OpenAIRE

    Mäthger, Lydia M.; Denton, Eric J.; Marshall, N. Justin; Hanlon, Roger T.

    2008-01-01

    Octopus, squid and cuttlefish are renowned for rapid adaptive coloration that is used for a wide range of communication and camouflage. Structural coloration plays a key role in augmenting the skin patterning that is produced largely by neurally controlled pigmented chromatophore organs. While most iridescence and white scattering is produced by passive reflectance or diffusion, some iridophores in squid are actively controlled via a unique cholinergic, non-synaptic neural system. We review t...

  20. Applications of color graphics to complex aerodynamic analysis

    Science.gov (United States)

    Weston, Robert P.

    1987-01-01

    A variety of uses for color graphics in the display of large sets of complex aerodynamic data in two and three dimensions are summarized. These methods improve the ability of a scientific researcher to interactively review three-dimensional displays of aircraft panel geometries for the purposes of eliminating errors, and allow him to rapidly display an assortment of smooth-shaded, color-coded illustrations for his experimental and computational results.