WorldWideScience

Sample records for rapid biochemical test

  1. An evaluation of the Oxoid Biochemical Identification System Campy rapid screening test for Campylobacteraceae and Helicobacter spp.

    Science.gov (United States)

    Hoosain, N; Lastovica, A J

    2009-06-01

    To evaluate the Oxoid Biochemical Identification System (OBIS) Campy test (ID0800M) against Campylobacter; Arcobacter; and other micro-organisms, with similar colonial morphology, for the detection of l-alanine aminopeptidase (l-ALA). The KOH and l-ALA (OBIS and Fluka) tests were carried out on every isolate. The procedures were followed as indicated in the OBIS and Fluka kit instructions. A total of 146 strains of 19 species of Campylobacter, seven strains of Arcobacter butzleri, four Arcobacter butzleri-like strains, 42 strains of 10 species of Helicobacter, 96 Gram-negative and 49 Gram-positive clinical isolates were tested. As expected, Campylobacter and Arcobacter strains were negative, while other Gram-negative bacteria were positive for the l-ALA test. An unexpected finding was that Helicobacter strains, although Gram-negative, were all negative for the l-ALA tests suggesting the absence of l-ALA within this genus. This is a novel finding. The absence of l-ALA was confirmed upon comparison with the available full genomic sequences of Helicobacter on the NCBI database. The OBIS Campy (ID0800M) test kit proved to be rapid and accurate for the presumptive characterization of Campylobacter and Arcobacter. A novel finding was that Helicobacter species also did not have the l-ALA enzyme. The OBIS kit will be useful in diagnostic laboratories for the presumptive diagnosis of Campylobacter, Arcobacter and Helicobacter strains.

  2. Recent advances in biochemical and molecular diagnostics for the rapid detection of antibiotic-resistant Enterobacteriaceae: a focus on ß-lactam resistance.

    Science.gov (United States)

    Decousser, Jean-Winoc; Poirel, Laurent; Nordmann, Patrice

    2017-04-01

    The rapid detection of resistance is a challenge for clinical microbiologists who wish to prevent deleterious individual and collective consequences such as (i) delaying efficient antibiotic therapy, which worsens the survival rate of the most severely ill patients, or (ii) delaying the isolation of the carriers of multidrug-resistant bacteria and promoting outbreaks; this last consequence is of special concern, and there are an increasing number of approaches and market-based solutions in response. Areas covered: From simple, cheap biochemical tests to whole-genome sequencing, clinical microbiologists must select the most adequate phenotypic and genotypic tools to promptly detect and confirm β-lactam resistance from cultivated bacteria or from clinical specimens. Here, the authors review the published literature from the last 5 years about the primary technical approaches and commercial laboratory reagents for these purposes, including molecular, biochemical and immune assays. Furthermore, the authors discuss their intrinsic and relative performance, and we challenge their putative clinical impact. Expert commentary: Until the availability of fully automated wet and dry whole genome sequencing solutions, microbiologists should focus on inexpensive biochemical tests for cultured isolates or monomicrobial clinical specimen and on using the expensive molecular PCR-based strategies for the targeted screening of complex biological environments.

  3. Diagnosis Of Inherited Neurometabolic Disorders : A Biochemical Approach

    Directory of Open Access Journals (Sweden)

    Christopher R

    1999-01-01

    Full Text Available The past two decades have witnessed a rapid increase in the knowledge of the inherited neurometabolic disorders. The precise diagnosis of these disorders which is a challenge to the physician can be best accomplished by biochemical methods. Screening of clinically selected patients with simple chemical urine tests and routine blood chemistry investigations followed by measurement of specific metabolites and assay of the relevant enzymes confirms the diagnosis in most cases. Biochemical diagnosis of inherited neurometabolic disorders although expensive is rapid and confirmatory and therefore aids in treatment and further prevention of these rare disorders.

  4. Modification of the Rappaport rapid test in large-scale testing for syphilis. Evaluation of the rapid plate and rapid card tests.

    Science.gov (United States)

    Ghinsberg, R; Meir, E; Blumstein, G; Kafeman, R

    1975-11-01

    The Rappaport rapid (RR) plate and card tests were developed as modifications of the RR tube test to permit rapid and inexpensive screening of large numbers of subjects for the diagnosis of syphilis. More than 2,000 sera were examined in parallel by the Venereal Disease Research Laboratory (VDRL) slide test, the rapid plasma reagin (RPR) card test and the RR plate and card tests. There was complete agreement between the RR plate and card tests and the VDRL slide and RPR card tests in 96.6% of sera. In a selected group of 1,530 sera examined, in addition, by the fluorescent treponemal antibody absorption (FTA-ABS) test, there was agreement between the RR plate and card tests and the FTA-ABS test in 74.3% of sera and between the VDRL and RPR tests and the FTA-ABS test in 73.7% of sera. The RR plate test was found to be sufficiently sensitive and specific for the diagnosis of syphilis, although the VDRL slide test is perhaps more sensitive in primary and late latent syphilis. Since the antigen used in the RR tests is colored and stable and the sera do not require inactivation before the test, the tests are easier to perform than the VDRL slide test: the RR plate and card tests could therefore replace the VDRL test as a screening test, with hardly any loss of accuracy.

  5. Variations in biochemical values for common laboratory tests: a comparison among multi-ethnic Israeli women cohort.

    Science.gov (United States)

    Birk, Ruth; Heifetz, Eliyahu M

    2018-04-28

    Biochemical laboratory values are an essential tool in medical diagnosis, treatment, and follow-up; however, they are known to vary between populations. Establishment of ethnicity-adjusted reference values is recommended by health organizations. To investigate the ethnicity element in biochemical lab values studying women of different ethnic groups. Biochemical lab values (n = 27) of 503 adult Israeli women of three ethnicities (Jewish Ashkenazi, Jewish Sephardic, and Bedouin Arab) attending a single medical center were analyzed. Biochemical data were extracted from medical center records. Ethnic differences of laboratory biochemicals were studied using ANCOVA to analyze the center of the distribution as well as quartile regression analysis to analyze the upper and lower limits, both done with an adjustment for age. Significant ethnic differences were found in almost half (n = 12) of the biochemical laboratory tests. Ashkenazi Jews exhibited significantly higher mean values compared to Bedouins in most of the biochemical tests, including albumin, alkaline phosphatase, calcium, cholesterol, cholesterol LDL and HDL, cholesterol LDL calc., folic acid, globulin, and iron saturation, while the Bedouins exhibited the highest mean values in the creatinine and triglycerides. For most of these tests, Sephardic Jews exhibited biochemical mean levels in between the two other groups. Compared to Ashkenazi Jews, Sephardic Jews had a significant shift to lower values in cholesterol LDL. Ethnic subpopulations have distinct distributions in biochemical laboratory test values, which should be taken into consideration in medical practice enabling precision medicine.

  6. 40 CFR 798.5195 - Mouse biochemical specific locus test.

    Science.gov (United States)

    2010-07-01

    ...-induced variants are bred to determine the genetic nature of the change. (f) Data and reports—(1... SUBSTANCES CONTROL ACT (CONTINUED) HEALTH EFFECTS TESTING GUIDELINES Genetic Toxicity § 798.5195 Mouse...) A biochemical specific locus mutation is a genetic change resulting from a DNA lesion causing...

  7. Use of predefined biochemical admission profiles does not reduce the number of tests or total cost

    DEFF Research Database (Denmark)

    Pareek, Manan; Haidl, Felix; Folkestad, Lars

    2014-01-01

    The objective of this pilot study was to evaluate whether the use of predefined biochemical profiles as an alternative to individually ordered blood tests by the treating physicians resulted in fewer tests or a lower total cost.......The objective of this pilot study was to evaluate whether the use of predefined biochemical profiles as an alternative to individually ordered blood tests by the treating physicians resulted in fewer tests or a lower total cost....

  8. Metabologenomics of Phaeochromocytoma and Paraganglioma: An Integrated Approach for Personalised Biochemical and Genetic Testing.

    Science.gov (United States)

    Eisenhofer, Graeme; Klink, Barbara; Richter, Susan; Lenders, Jacques Wm; Robledo, Mercedes

    2017-04-01

    The tremendous advances over the past two decades in both clinical genetics and biochemical testing of chromaffin cell tumours have led to new considerations about how these aspects of laboratory medicine can be integrated to improve diagnosis and management of affected patients. With germline mutations in 15 genes now identified to be responsible for over a third of all cases of phaeochromocytomas and paragangliomas, these tumours are recognised to have one of the richest hereditary backgrounds among all neoplasms. Depending on the mutation, tumours show distinct differences in metabolic pathways that relate to or even directly impact clinical presentation. At the same time, there has been improved understanding about how catecholamines are synthesised, stored, secreted and metabolised by chromaffin cell tumours. Although the tumours may not always secrete catecholamines it has become clear that almost all continuously produce and metabolise catecholamines. This has not only fuelled changes in laboratory medicine, but has also assisted in recognition of genotype-biochemical phenotype relationships important for diagnostics and clinical care. In particular, differences in catecholamine and energy pathway metabolomes can guide genetic testing, assist with test interpretation and provide predictions about the nature, behaviour and imaging characteristics of the tumours. Conversely, results of genetic testing are important for guiding how routine biochemical testing should be employed and interpreted in surveillance programmes for at-risk patients. In these ways there are emerging needs for modern laboratory medicine to seamlessly integrate biochemical and genetic testing into the diagnosis and management of patients with chromaffin cell tumours.

  9. Comparative evaluation of two rapid field tests for malaria diagnosis: Partec Rapid Malaria Test® and Binax Now® Malaria Rapid Diagnostic Test.

    Science.gov (United States)

    Nkrumah, Bernard; Acquah, Samuel Ek; Ibrahim, Lukeman; May, Juergen; Brattig, Norbert; Tannich, Egbert; Nguah, Samuel Blay; Adu-Sarkodie, Yaw; Huenger, Frank

    2011-05-23

    About 90% of all malaria deaths in sub-Saharan Africa occur in children under five years. Fast and reliable diagnosis of malaria requires confirmation of the presence of malaria parasites in the blood of patients with fever or history suggestive of malaria; hence a prompt and accurate diagnosis of malaria is the key to effective disease management. Confirmation of malaria infection requires the availability of a rapid, sensitive, and specific testing at an affordable cost. We compared two recent methods (the novel Partec Rapid Malaria Test® (PT) and the Binax Now® Malaria Rapid Diagnostic Test (BN RDT) with the conventional Giemsa stain microscopy (GM) for the diagnosis of malaria among children in a clinical laboratory of a hospital in a rural endemic area of Ghana. Blood samples were collected from 263 children admitted with fever or a history of fever to the pediatric clinic of the Agogo Presbyterian Hospital. The three different test methods PT, BN RDT and GM were performed independently by well trained and competent laboratory staff to assess the presence of malaria parasites. Results were analyzed and compared using GM as the reference standard. In 107 (40.7%) of 263 study participants, Plasmodium sp. was detected by GM. PT and BN RDT showed positive results in 111 (42.2%) and 114 (43.4%), respectively. Compared to GM reference standard, the sensitivities of the PT and BN RDT were 100% (95% CI: 96.6-100) and 97.2% (95% CI: 92.0-99.4), respectively, specificities were 97.4% (95% CI: 93.6-99.3) and 93.6% (95% CI: 88.5-96.9), respectively. There was a strong agreement (kappa) between the applied test methods (GM vs PT: 0.97; p < 0.001 and GM vs BN RDT: 0.90; p < 0.001). The average turnaround time per tests was 17 minutes. In this study two rapid malaria tests, PT and BN RDT, demonstrated a good quality of their performance compared to conventional GM. Both methods require little training, have short turnaround times, are applicable as well as affordable and

  10. Rapid Discrimination Among Putative Mechanistic Models of Biochemical Systems.

    Science.gov (United States)

    Lomnitz, Jason G; Savageau, Michael A

    2016-08-31

    An overarching goal in molecular biology is to gain an understanding of the mechanistic basis underlying biochemical systems. Success is critical if we are to predict effectively the outcome of drug treatments and the development of abnormal phenotypes. However, data from most experimental studies is typically noisy and sparse. This allows multiple potential mechanisms to account for experimental observations, and often devising experiments to test each is not feasible. Here, we introduce a novel strategy that discriminates among putative models based on their repertoire of qualitatively distinct phenotypes, without relying on knowledge of specific values for rate constants and binding constants. As an illustration, we apply this strategy to two synthetic gene circuits exhibiting anomalous behaviors. Our results show that the conventional models, based on their well-characterized components, cannot account for the experimental observations. We examine a total of 40 alternative hypotheses and show that only 5 have the potential to reproduce the experimental data, and one can do so with biologically relevant parameter values.

  11. Rapid biochemical functionalization of technical surfaces by means of a photobleaching-based maskless projection lithography process

    Science.gov (United States)

    Waldbaur, Ansgar; Waterkotte, Björn; Leuthold, Juerg; Schmitz, Katja; Rapp, Bastian E.

    2013-03-01

    MEMS/MOEMS based systems are increasingly applied in the biological and biomedical context, e.g. in form of biosensors or substrates for monitoring biological responses such as cell migration. For such applications, technical surfaces have to be provided with suitable biochemical functionalization. Typical functionalization procedures include wet-chemical techniques based on self-assembled monolayers of thiols on gold or silanes on glass. These processes create binary patterns and are often of limited use if spatially constrained non-binary patterns like surface bound biochemical gradients have to be provided. In order to create gradients or patterns, methods such as direct spotting or dip pen nanolithography can be used. Here, gradients can be emulated by varying the spot density or the concentration of the solutions employed. However, these methods are serial in nature and are thus of limited use if large surface areas have to be patterned. We present a technique to generate gradients of biochemical function by a photobleaching-based process allowing fast large-scale patterning. The process is based on photobleaching resulting in light-induced coupling of a fluorescently tagged biomolecule to a technical surface by concerted bleaching of the fluorophore. We custom designed a maskless projection lithography system based on a digital mirror device that allows the rapid creation of 8-bit grayscale protein patterns on any technical surface from digital data (e.g. bitmap files). We demonstrate how this process can be used to obtain patterns of several cm2 lateral size at micrometer resolution within minutes.

  12. Good laboratory practices for biochemical genetic testing and newborn screening for inherited metabolic disorders.

    Science.gov (United States)

    2012-04-06

    Biochemical genetic testing and newborn screening are essential laboratory services for the screening, detection, diagnosis, and monitoring of inborn errors of metabolism or inherited metabolic disorders. Under the Clinical Laboratory Improvement Amendments of 1988 (CLIA) regulations, laboratory testing is categorized on the basis of the level of testing complexity as either waived (i.e., from routine regulatory oversight) or nonwaived testing (which includes tests of moderate and high complexity). Laboratories that perform biochemical genetic testing are required by CLIA regulations to meet the general quality systems requirements for nonwaived testing and the personnel requirements for high-complexity testing. Laboratories that perform public health newborn screening are subject to the same CLIA regulations and applicable state requirements. As the number of inherited metabolic diseases that are included in state-based newborn screening programs continues to increase, ensuring the quality of performance and delivery of testing services remains a continuous challenge not only for public health laboratories and other newborn screening facilities but also for biochemical genetic testing laboratories. To help ensure the quality of laboratory testing, CDC collaborated with the Centers for Medicare & Medicaid Services, the Food and Drug Administration, the Health Resources and Services Administration, and the National Institutes of Health to develop guidelines for laboratories to meet CLIA requirements and apply additional quality assurance measures for these areas of genetic testing. This report provides recommendations for good laboratory practices that were developed based on recommendations from the Clinical Laboratory Improvement Advisory Committee, with additional input from the Secretary's Advisory Committee on Genetics, Health, and Society; the Secretary's Advisory Committee on Heritable Disorders in Newborns and Children; and representatives of newborn

  13. Rapid Aminoglycoside NP Test for Rapid Detection of Multiple Aminoglycoside Resistance in Enterobacteriaceae.

    Science.gov (United States)

    Nordmann, Patrice; Jayol, Aurélie; Dobias, Jan; Poirel, Laurent

    2017-04-01

    The rapid aminoglycoside NP (Nordmann/Poirel) test was developed to rapidly identify multiple aminoglycoside (AG) resistance in Enterobacteriaceae It is based on the detection of the glucose metabolism related to enterobacterial growth in the presence of a defined concentration of amikacin plus gentamicin. Formation of acid metabolites was evidenced by a color change (orange to yellow) of the red phenol pH indicator. The rapid aminoglycoside NP test was evaluated by using bacterial colonies of 18 AG-resistant isolates producing 16S rRNA methylases, 20 AG-resistant isolates expressing AG-modifying enzymes (acetyl-, adenyl-, and phosphotransferases), and 10 isolates susceptible to AG. Its sensitivity and specificity were 100% and 97%, respectively, compared to the broth dilution method, which was taken as the gold standard for determining aminoglycoside resistance. The test is inexpensive, rapid (<2 h), and implementable worldwide. Copyright © 2017 American Society for Microbiology.

  14. Usefulness of Leukocyte Esterase Test Versus Rapid Strep Test for Diagnosis of Acute Strep Pharyngitis

    Directory of Open Access Journals (Sweden)

    Kumara V. Nibhanipudi MD

    2015-08-01

    Full Text Available Objective: A study to compare the usage of throat swab testing for leukocyte esterase on a test strip(urine dip stick-multi stick to rapid strep test for rapid diagnosis of Group A Beta hemolytic streptococci in cases of acute pharyngitis in children. Hypothesis: The testing of throat swab for leukocyte esterase on test strip currently used for urine testing may be used to detect throat infection and might be as useful as rapid strep. Methods: All patients who come with a complaint of sore throat and fever were examined clinically for erythema of pharynx, tonsils and also for any exudates. Informed consent was obtained from the parents and assent from the subjects. 3 swabs were taken from pharyngo-tonsillar region, testing for culture, rapid strep & Leukocyte Esterase. Results: Total number is 100. Cultures 9(+; for rapid strep== 84(- and16 (+; For LE== 80(- and 20(+ Statistics: From data configuration Rapid Strep versus LE test don’t seem to be a random (independent assignment but extremely aligned. The Statistical results show rapid and LE show very agreeable results. Calculated Value of Chi Squared Exceeds Tabulated under 1 Degree Of Freedom (P<.0.0001 reject Null Hypothesis and Conclude Alternative Conclusions: Leukocyte esterase on throat swab is as useful as rapid strep test for rapid diagnosis of strep pharyngitis on test strip currently used for urine dip stick causing acute pharyngitis in children.

  15. Evaluation of rapid HIV test kits on whole blood and development of rapid testing algorithm for voluntary testing and counseling centers in Ethiopia.

    Science.gov (United States)

    Tegbaru, Belete; Messele, Tsehaynesh; Wolday, Dawit; Meles, PhD Hailu; Tesema, Desalegn; Birhanu, Hiwot; Tesfaye, Girma; Bond, Kyle B; Martin, Robert; Rayfield, Mark A; Wuhib, Tadesse; Fekadu, Makonnen

    2004-10-01

    Five simple and rapid HIV antibody detection assays viz. Determine, Capillus, Oraquick, Unigold and Hemastrip were evaluated to examine their performance and to develop an alternative rapid test based testing algorithm for voluntary counseling and testing (VCT) in Ethiopia. All the kits were tested on whole blood, plasma and serum. The evaluation had three phases: Primary lab review, piloting at point of service and implementation. This report includes the results of the first two phases. A total of 2,693 specimens (both whole blood and plasma) were included in the evaluation. Results were compared to double Enzyme Linked Immuno-Sorbent Assay (ELISA) system. Discordant EIA results were resolved using Western Blot. The assays had very good sensitivities and specificities, 99-100%, at the two different phases of the evaluation. A 98-100% result agreement was obtained from those tested at VCT centers and National Referral Laboratory for AIDS (NRLA), in the quality control phase of the evaluation. A testing strategy yielding 100% [95% CI; 98.9-100.0] sensitivity was achieved by the sequential use of the three rapid test kits. Direct cost comparison showed serial testing algorithm reduces the cost of testing by over 30% compared to parallel testing in the current situation. Determine, Capillus/Oraquick (presence/absence of frefrigeration) and Unigold were recommended as screening, confirmation and tiebreaker tests, respectively.

  16. Rapid Diagnostic Tests for Malaria: A Review

    Science.gov (United States)

    2005-06-01

    4.92% 0% 100% [25] France** 557 15.5% 1.3%*** 100% 14.3% 1.3%*** 100% [26] Kuwait** 240 0% - 75.4% - - - [27] Peru 72 - - - 7.7% 0% 100% [28...expression of aldolase isoenzymes in the rodent malaria parasite Plasmodium berghei. Mol. Biochem. Parasitol., 52, 15-27. [21] Cloonan, N., Fischer...R. L. (2003). Performance of an immunochromatography test for vivax malaria in the Amazon region, Brazil. Rev. Saude Publica, 37, 390-392. [69

  17. Rapid pile load tests in the geotechnical centrifuge

    NARCIS (Netherlands)

    Holscher, P.; Van Tol, A.F.; Huy, N.Q.

    2012-01-01

    Centrifiige experiments were carried out to gain insight into the factors that affect the mobilized resistance during rapid load testing on piles in sand. The influence of generated pore water pressure during rapid load tests is shidied, and its effect on the commonly used unloadmg point method to

  18. Mercury Induced Biochemical Alterations As Oxidative Stress In Mugil Cephalus In Short Term Toxicity Test

    OpenAIRE

    J.S.I Rajkumar; Samuel Tennyson

    2013-01-01

    Mugil cephalus juveniles of size 2.5 ±0.6cm were exposed to mercury in short term chronic toxicity test through static renewal bioassay to detect the possible biochemical agent as biomarkers in aquatic pollution and in estuarine contamination as specific. Lipid peroxidation levels, glutathione S -transferase, catalase, reduced glutathione and acetylcholinesterase were studied as biochemical parameters. Increased thio-barbituric acid reactive substances levels were observed under exposur...

  19. Coagulation Tests and Selected Biochemical Analytes in Dairy Cows with Hepatic Lipidosis

    OpenAIRE

    S. Padilla-Arellanes; F. Constantino-Casas; L. Núnez-Ochoa; J. Doubek; C. Vega-Murguia; J. Bouda

    2007-01-01

    The aim of this study was to determine the values and changes in conventional and optimised clotting tests, as well as in selected biochemical analytes during hepatic lipidosis in postpartum dairy cows. Ten healthy and ten Holstein cows with hepatic lipidosis were selected based upon clinical history, clinical examination, liver biopsy, flotation test and histological analysis of hepatic tissue. Prothrombin time (PT) and partial thromboplastin time (PTT) were determined in non-diluted and dil...

  20. The microdose rapid 14C urea breath test compares well with the original rapid 14 breath test

    International Nuclear Information System (INIS)

    Bellon, M.S.; Bartholomeusz, F.D.L.; Chatterton, B.E.

    2000-01-01

    Full text: The 14 C urea breath test (CUBT) is a sensitive test used in the detection of H. pylori infection. The rapid 14 CUBT using 185 KBq of 14 C urea showed a sensitivity of 100% when tested in 36 patients. The aim of this study was to compare the results of the 14 CUBT performed following the ingestion of 37KBq microdose 14 C urea capsule (Bicapsule, Trimed) with the earlier method which uses 185 KBq 14 C urea. 19 patients (nine female age 21-52 yrs) were studied. All subjects first underwent a 14 CUBT with the microdose capsule and a single 15 minute post ingestion sample. An hour later the test was repeated but with a dose of 185 KBq 14 C urea in liquid form. A normal result was taken as 2 = 0.92). This is shown above. The Rapid 14 CUBT performed following the microdose capsule whilst reducing patient radiation exposure is an accurate test for the detection of H. pylori. Copyright (2000) The Australian and New Zealand Society of Nuclear Medicine Inc

  1. Comparison of Xpert Flu rapid nucleic acid testing with rapid antigen testing for the diagnosis of influenza A and B.

    Science.gov (United States)

    DiMaio, Michael A; Sahoo, Malaya K; Waggoner, Jesse; Pinsky, Benjamin A

    2012-12-01

    Influenza infections are associated with thousands of hospital admissions and deaths each year. Rapid detection of influenza is important for prompt initiation of antiviral therapy and appropriate patient triage. In this study the Cepheid Xpert Flu assay was compared with two rapid antigen tests, BinaxNOW Influenza A & B and BD Directigen EZ Flu A+B, as well as direct fluorescent antibody testing for the rapid detection of influenza A and B. Using real-time, hydrolysis probe-based, reverse transcriptase PCR as the reference method, influenza A sensitivity was 97.3% for Xpert Flu, 95.9% for direct fluorescent antibody testing, 62.2% for BinaxNOW, and 71.6% for BD Directigen. Influenza B sensitivity was 100% for Xpert Flu and direct fluorescent antibody testing, 54.5% for BinaxNOW, and 48.5% for BD Directigen. Specificity for influenza A was 100% for Xpert Flu, BinaxNOW, and BD Directigen, and 99.2% for direct fluorescent antibody testing. All methods demonstrated 100% specificity for influenza B. These findings support the use of the Xpert Flu assay in settings requiring urgent diagnosis of influenza A and B. Copyright © 2012 Elsevier B.V. All rights reserved.

  2. A comparison of rapid diagnostic testing (by plasmodium lactate ...

    African Journals Online (AJOL)

    Background: The World Health Organization (WHO) considers early and rapid diagnosis as one of the strategies to control malaria. This study compared the performance of Quantitative Buffy Coat (QBC) test and the Plasmodium lactate dehydrogenase (pLDH) rapid diagnostic test (RDT) with microscopy as the gold ...

  3. Evaluation of a rapid immunodiagnostic test kit for rabies virus.

    Science.gov (United States)

    Kang, BoKyu; Oh, JinSik; Lee, ChulSeung; Park, Bong-Kyun; Park, YoungNam; Hong, KyungSoo; Lee, KyungGi; Cho, ByungKi; Song, DaeSub

    2007-10-01

    A rapid immunodiagnostic test kit for rabies virus detection was evaluated using 51 clinical samples and 4 isolates of rabies virus. The quick detection of rabies virus under field conditions may be helpful in determining if post-exposure prophylaxis is needed, thereby avoiding unnecessary treatments, as well as undue economic burden. There are several widely used diagnostic methods for rabies, including fluorescent antibody tests, reverse transcription polymerase chain reaction, and electron microscopy; however, these methods include time-consuming, intricate, and costly procedures. The rapid immunodiagnostic test was able to detect rabies virus in clinical samples, including brain tissue and saliva, in addition to 10(3.2) 50% lethal dose (LD(50))/mL cell-adapted rabies virus. The assay was not cross-reactive with non-rabies virus microbes. When the performance of the rapid immunodiagnostic test was compared to a fluorescent antibody test, the rapid immunodiagnostic test had a sensitivity of 91.7% and specificity of 100% (95.8% CI).

  4. Low specificity of 2 tetanus rapid tests in Cambodia.

    Science.gov (United States)

    Schlumberger, M; Yvonnet, B; Lesage, G; Tep, B

    2015-01-01

    Rapid testing for tetanus on serum or blood allows for an immediate evaluation of individual protection against tetanus in developed countries, using a "single step" immunochromatographic technique using tetanus toxoid. The specificity of these tests, compared to the reference method for tetanus, mouse serum neutralization testing, has however never been assessed in these countries, due to the difficulty to perform serum neutralization titration in mice, because of animal testing bioethical regulations. A collection of sera from adult volunteers in Cambodia, living in rural environment, was tested for tetanus antibodies by ELISA in France, and by mouse serum neutralization in Vietnam. This allowed estimating the sensitivity and specificity of 2 rapid tetanus tests, available on the market: TQS™ and Tetanotop™. The sensitivity of these tests was adequate, compared to mice serum neutralization test, for a test threshold of 0.01 IU/mL, (100% for TQS™, 91% for Tetanotop™), but their specificity was very low (1% for TQS™ and 13% for Tetanotop™). The results prove that these rapid tests for the assessment of individual protection against tetanus should not be used in the adult rural Cambodian population. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  5. Analysis of the Rapid Chloride Migration test

    NARCIS (Netherlands)

    Spiesz, P.R.; Ballari, M.; Brouwers, H.J.H.; Ferreira, R. M.; Gulikers, J.; Andrade, C.

    2009-01-01

    In this study the Rapid Chloride Migration test (RCM) standardized as NT Build 492 and BAW-Merkblatt is reviewed. Since the traditional natural diffusion tests are laborious, time consuming and costly, they are not always preferred from a practical point of view. To overcome these disadvantages,

  6. Integration of electrochemistry in micro-total analysis systems for biochemical assays: recent developments.

    Science.gov (United States)

    Xu, Xiaoli; Zhang, Song; Chen, Hui; Kong, Jilie

    2009-11-15

    Micro-total analysis systems (microTAS) integrate different analytical operations like sample preparation, separation and detection into a single microfabricated device. With the outstanding advantages of low cost, satisfactory analytical efficiency and flexibility in design, highly integrated and miniaturized devices from the concept of microTAS have gained widespread applications, especially in biochemical assays. Electrochemistry is shown to be quite compatible with microanalytical systems for biochemical assays, because of its attractive merits such as simplicity, rapidity, high sensitivity, reduced power consumption, and sample/reagent economy. This review presents recent developments in the integration of electrochemistry in microdevices for biochemical assays. Ingenious microelectrode design and fabrication methods, and versatility of electrochemical techniques are involved. Practical applications of such integrated microsystem in biochemical assays are focused on in situ analysis, point-of-care testing and portable devices. Electrochemical techniques are apparently suited to microsystems, since easy microfabrication of electrochemical elements and a high degree of integration with multi-analytical functions can be achieved at low cost. Such integrated microsystems will play an increasingly important role for analysis of small volume biochemical samples. Work is in progress toward new microdevice design and applications.

  7. Potential for false positive HIV test results with the serial rapid HIV testing algorithm.

    Science.gov (United States)

    Baveewo, Steven; Kamya, Moses R; Mayanja-Kizza, Harriet; Fatch, Robin; Bangsberg, David R; Coates, Thomas; Hahn, Judith A; Wanyenze, Rhoda K

    2012-03-19

    Rapid HIV tests provide same-day results and are widely used in HIV testing programs in areas with limited personnel and laboratory infrastructure. The Uganda Ministry of Health currently recommends the serial rapid testing algorithm with Determine, STAT-PAK, and Uni-Gold for diagnosis of HIV infection. Using this algorithm, individuals who test positive on Determine, negative to STAT-PAK and positive to Uni-Gold are reported as HIV positive. We conducted further testing on this subgroup of samples using qualitative DNA PCR to assess the potential for false positive tests in this situation. Of the 3388 individuals who were tested, 984 were HIV positive on two consecutive tests, and 29 were considered positive by a tiebreaker (positive on Determine, negative on STAT-PAK, and positive on Uni-Gold). However, when the 29 samples were further tested using qualitative DNA PCR, 14 (48.2%) were HIV negative. Although this study was not primarily designed to assess the validity of rapid HIV tests and thus only a subset of the samples were retested, the findings show a potential for false positive HIV results in the subset of individuals who test positive when a tiebreaker test is used in serial testing. These findings highlight a need for confirmatory testing for this category of individuals.

  8. Rapid Weight Loss Elicits Harmful Biochemical and Hormonal Responses in Mixed Martial Arts Athletes.

    Science.gov (United States)

    Coswig, Victor Silveira; Fukuda, David Hideyoshi; Del Vecchio, Fabrício Boscolo

    2015-10-01

    The purpose of this study was to compare biochemical and hormonal responses between mixed martial arts (MMA) competitors with minimal prefight weight loss and those undergoing rapid weight loss (RWL). Blood samples were taken from 17 MMA athletes (Mean± SD; age: 27.4 ±5.3yr; body mass: 76.2 ± 12.4kg; height: 1.71 ± 0.05m and training experience: 39.4 ± 25 months) before and after each match, according to the official events rules. The no rapid weight loss (NWL, n = 12) group weighed in on the day of the event (~30 min prior fight) and athletes declared not having used RWL strategies, while the RWL group (n = 5) weighed in 24 hr before the event and the athletes claimed to have lost 7.4 ± 1.1kg, approximately 10% of their body mass in the week preceding the event. Results showed significant (p < .05) increases following fights, regardless of group, in lactate, glucose, lactate dehydrogenase (LDH), creatinine, and cortisol for all athletes. With regard to group differences, NWL had significantly (p < .05) greater creatinine levels (Mean± SD; pre to post) (NWL= 101.6 ± 15-142.3 ± 22.9μmol/L and RWL= 68.9 ± 10.6-79.5 ± 15.9μmol/L), while RWL had higher LDH (median [interquartile range]; pre to post) (NWL= 211.5[183-236] to 231[203-258]U/L and RWL= 390[370.5-443.5] to 488[463.5-540.5]U/L) and AST (NWL= 30[22-37] to 32[22-41]U/L and 39[32.5-76.5] to 72[38.5-112.5] U/L) values (NWL versus RWL, p < .05). Post hoc analysis showed that AST significantly increased in only the RWL group, while creatinine increased in only the NWL group. The practice of rapid weight loss showed a negative impact on energy availability and increased both muscle damage markers and catabolic expression in MMA fighters.

  9. The quality of veterinary in-clinic and reference laboratory biochemical testing.

    Science.gov (United States)

    Rishniw, Mark; Pion, Paul D; Maher, Tammy

    2012-03-01

    Although evaluation of biochemical analytes in blood is common in veterinary practice, studies assessing the global quality of veterinary in-clinic and reference laboratory testing have not been reported. The aim of this study was to assess the quality of biochemical testing in veterinary laboratories using results obtained from analyses of 3 levels of assayed quality control materials over 5 days. Quality was assessed by comparison of calculated total error with quality requirements, determination of sigma metrics, use of a quality goal index to determine factors contributing to poor performance, and agreement between in-clinic and reference laboratory mean results. The suitability of in-clinic and reference laboratory instruments for statistical quality control was determined using adaptations from the computerized program, EZRules3. Reference laboratories were able to achieve desirable quality requirements more frequently than in-clinic laboratories. Across all 3 materials, > 50% of in-clinic analyzers achieved a sigma metric ≥ 6.0 for measurement of 2 analytes, whereas > 50% of reference laboratory analyzers achieved a sigma metric ≥ 6.0 for measurement of 6 analytes. Expanded uncertainty of measurement and ± total allowable error resulted in the highest mean percentages of analytes demonstrating agreement between in-clinic and reference laboratories. Owing to marked variation in bias and coefficient of variation between analyzers of the same and different types, the percentages of analytes suitable for statistical quality control varied widely. These findings reflect the current state-of-the-art with regard to in-clinic and reference laboratory analyzer performance and provide a baseline for future evaluations of the quality of veterinary laboratory testing. © 2012 American Society for Veterinary Clinical Pathology.

  10. Potential for false positive HIV test results with the serial rapid HIV testing algorithm

    Directory of Open Access Journals (Sweden)

    Baveewo Steven

    2012-03-01

    Full Text Available Abstract Background Rapid HIV tests provide same-day results and are widely used in HIV testing programs in areas with limited personnel and laboratory infrastructure. The Uganda Ministry of Health currently recommends the serial rapid testing algorithm with Determine, STAT-PAK, and Uni-Gold for diagnosis of HIV infection. Using this algorithm, individuals who test positive on Determine, negative to STAT-PAK and positive to Uni-Gold are reported as HIV positive. We conducted further testing on this subgroup of samples using qualitative DNA PCR to assess the potential for false positive tests in this situation. Results Of the 3388 individuals who were tested, 984 were HIV positive on two consecutive tests, and 29 were considered positive by a tiebreaker (positive on Determine, negative on STAT-PAK, and positive on Uni-Gold. However, when the 29 samples were further tested using qualitative DNA PCR, 14 (48.2% were HIV negative. Conclusion Although this study was not primarily designed to assess the validity of rapid HIV tests and thus only a subset of the samples were retested, the findings show a potential for false positive HIV results in the subset of individuals who test positive when a tiebreaker test is used in serial testing. These findings highlight a need for confirmatory testing for this category of individuals.

  11. A reduced-order adaptive neuro-fuzzy inference system model as a software sensor for rapid estimation of five-day biochemical oxygen demand

    Science.gov (United States)

    Noori, Roohollah; Safavi, Salman; Nateghi Shahrokni, Seyyed Afshin

    2013-07-01

    The five-day biochemical oxygen demand (BOD5) is one of the key parameters in water quality management. In this study, a novel approach, i.e., reduced-order adaptive neuro-fuzzy inference system (ROANFIS) model was developed for rapid estimation of BOD5. In addition, an uncertainty analysis of adaptive neuro-fuzzy inference system (ANFIS) and ROANFIS models was carried out based on Monte-Carlo simulation. Accuracy analysis of ANFIS and ROANFIS models based on both developed discrepancy ratio and threshold statistics revealed that the selected ROANFIS model was superior. Pearson correlation coefficient (R) and root mean square error for the best fitted ROANFIS model were 0.96 and 7.12, respectively. Furthermore, uncertainty analysis of the developed models indicated that the selected ROANFIS had less uncertainty than the ANFIS model and accurately forecasted BOD5 in the Sefidrood River Basin. Besides, the uncertainty analysis also showed that bracketed predictions by 95% confidence bound and d-factor in the testing steps for the selected ROANFIS model were 94% and 0.83, respectively.

  12. Rapid paper disk test for identification of Helicobacter pylori in mixed cultures of gerbil gastric homogenates.

    Science.gov (United States)

    Castillo-Juarez, Israel; Rangel-Vega, Adrian; Romero, Irma

    2010-10-01

    A method denominated rapid paper disk test (RPDT) was developed to identify H. pylori colonies in complex cultures obtained from gerbil gastric homogenates. Identification is based on a characteristic reaction pattern (RP) for H. pylori colonies given by the combination of the urease-oxidase activities on a paper disk. Compared to the RPs obtained from gerbil's intestinal tract isolated bacteria, H. pylori RP is completely distinguishable, even from those of bacteria that share one or both activities as are Aerococcus urinae, Bacillus sphaericus, Bacillus brevis, Corynebacterium pseudogenitalium, and Staphylococcus simulans, as well as from those produced by collection strains Proteus vulgaris and Pseudomonas aeruginosa. This method allows the practical quantification of H. pylori colonies in highly contaminated plates. RPDT has the following advantages over other methodologies that use indicators in the medium: it employs two of the three routinely used H. pylori biochemical identification tests, the reagents do not interfere with bacterial viability, there are no restrictions in relation to the medium used, and it is a simple, fast, and low-cost method. Copyright © 2010 Elsevier B.V. All rights reserved.

  13. Determination of HIV Status in African Adults With Discordant HIV Rapid Tests.

    Science.gov (United States)

    Fogel, Jessica M; Piwowar-Manning, Estelle; Donohue, Kelsey; Cummings, Vanessa; Marzinke, Mark A; Clarke, William; Breaud, Autumn; Fiamma, Agnès; Donnell, Deborah; Kulich, Michal; Mbwambo, Jessie K K; Richter, Linda; Gray, Glenda; Sweat, Michael; Coates, Thomas J; Eshleman, Susan H

    2015-08-01

    In resource-limited settings, HIV infection is often diagnosed using 2 rapid tests. If the results are discordant, a third tie-breaker test is often used to determine HIV status. This study characterized samples with discordant rapid tests and compared different testing strategies for determining HIV status in these cases. Samples were previously collected from 173 African adults in a population-based survey who had discordant rapid test results. Samples were classified as HIV positive or HIV negative using a rigorous testing algorithm that included two fourth-generation tests, a discriminatory test, and 2 HIV RNA tests. Tie-breaker tests were evaluated, including rapid tests (1 performed in-country), a third-generation enzyme immunoassay, and two fourth-generation tests. Selected samples were further characterized using additional assays. Twenty-nine samples (16.8%) were classified as HIV positive and 24 of those samples (82.8%) had undetectable HIV RNA. Antiretroviral drugs were detected in 1 sample. Sensitivity was 8.3%-43% for the rapid tests; 24.1% for the third-generation enzyme immunoassay; 95.8% and 96.6% for the fourth-generation tests. Specificity was lower for the fourth-generation tests than the other tests. Accuracy ranged from 79.5% to 91.3%. In this population-based survey, most HIV-infected adults with discordant rapid tests were virally suppressed without antiretroviral drugs. Use of individual assays as tie-breaker tests was not a reliable method for determining HIV status in these individuals. More extensive testing algorithms that use a fourth-generation screening test with a discriminatory test and HIV RNA test are preferable for determining HIV status in these cases.

  14. Centrifuge modeling of rapid load tests with open-ended piles

    NARCIS (Netherlands)

    Nguyen, T.C.; Van Lottum, H.; Holscher, P.; Van Tol, A.F.

    2012-01-01

    Rapid and static load tests were conducted on open-ended and close-ended piles in the Deltares GeoCentriflige. hi flight, a pile was driven into the soil. Both fme-grained sand and silt beds were tested. Both the rapid and static soil resistances o f a close-ended pile were higher than the soil

  15. Improving Marine Ecosystem Models with Biochemical Tracers

    Science.gov (United States)

    Pethybridge, Heidi R.; Choy, C. Anela; Polovina, Jeffrey J.; Fulton, Elizabeth A.

    2018-01-01

    Empirical data on food web dynamics and predator-prey interactions underpin ecosystem models, which are increasingly used to support strategic management of marine resources. These data have traditionally derived from stomach content analysis, but new and complementary forms of ecological data are increasingly available from biochemical tracer techniques. Extensive opportunities exist to improve the empirical robustness of ecosystem models through the incorporation of biochemical tracer data and derived indices, an area that is rapidly expanding because of advances in analytical developments and sophisticated statistical techniques. Here, we explore the trophic information required by ecosystem model frameworks (species, individual, and size based) and match them to the most commonly used biochemical tracers (bulk tissue and compound-specific stable isotopes, fatty acids, and trace elements). Key quantitative parameters derived from biochemical tracers include estimates of diet composition, niche width, and trophic position. Biochemical tracers also provide powerful insight into the spatial and temporal variability of food web structure and the characterization of dominant basal and microbial food web groups. A major challenge in incorporating biochemical tracer data into ecosystem models is scale and data type mismatches, which can be overcome with greater knowledge exchange and numerical approaches that transform, integrate, and visualize data.

  16. Comparison of Rapid Malaria Test and Laboratory Microscopy ...

    African Journals Online (AJOL)

    Michael Horsfall

    ABSTRACT: Blood samples collected from 272 volunteers in two communities of Bayelsa State in the Niger. Delta area were investigated for falciparum malaria parasite using the rapid test based on the detection of soluble antigen and laboratory microscopy test. The data showed that out of the 272 samples collected, ...

  17. RMBNToolbox: random models for biochemical networks

    Directory of Open Access Journals (Sweden)

    Niemi Jari

    2007-05-01

    Full Text Available Abstract Background There is an increasing interest to model biochemical and cell biological networks, as well as to the computational analysis of these models. The development of analysis methodologies and related software is rapid in the field. However, the number of available models is still relatively small and the model sizes remain limited. The lack of kinetic information is usually the limiting factor for the construction of detailed simulation models. Results We present a computational toolbox for generating random biochemical network models which mimic real biochemical networks. The toolbox is called Random Models for Biochemical Networks. The toolbox works in the Matlab environment, and it makes it possible to generate various network structures, stoichiometries, kinetic laws for reactions, and parameters therein. The generation can be based on statistical rules and distributions, and more detailed information of real biochemical networks can be used in situations where it is known. The toolbox can be easily extended. The resulting network models can be exported in the format of Systems Biology Markup Language. Conclusion While more information is accumulating on biochemical networks, random networks can be used as an intermediate step towards their better understanding. Random networks make it possible to study the effects of various network characteristics to the overall behavior of the network. Moreover, the construction of artificial network models provides the ground truth data needed in the validation of various computational methods in the fields of parameter estimation and data analysis.

  18. A comparison of test statistics for the recovery of rapid growth-based enumeration tests

    NARCIS (Netherlands)

    van den Heuvel, Edwin R.; IJzerman-Boon, Pieta C.

    This paper considers five test statistics for comparing the recovery of a rapid growth-based enumeration test with respect to the compendial microbiological method using a specific nonserial dilution experiment. The finite sample distributions of these test statistics are unknown, because they are

  19. EU-approved rapid tests might underestimate bovine spongiform encephalopathy infection in goats

    NARCIS (Netherlands)

    Meloni, Daniela; Bozzetta, Elena; Langeveld, Jan P.M.; Groschup, Martin H.; Goldmann, Wilfred; Andrèoletti, Olivier; Lantier, Isabelle; Keulen, Van Lucien; Bossers, Alex; Pitardi, Danilo; Nonno, Romolo; Sklaviadis, Theodoros; Ingravalle, Francesco; Peletto, Simone; Colussi, Silvia; Acutis, Pier Luigi

    2017-01-01

    We report the diagnostic sensitivity of 3 EU-approved rapid tests (ELISAs; 1 from IDEXX and 2 from Bio-Rad) for the detection of transmissible spongiform encephalopathy diseases in goats. Ninety-eight goat brainstem samples were tested. All the rapid tests had 100% specificity and ≥80% sensitivity,

  20. Rapid lysostaphin test to differentiate Staphylococcus and Micrococcus species.

    Science.gov (United States)

    Geary, C; Stevens, M

    1986-01-01

    A rapid, simple lysostaphin lysis susceptibility test to differentiate the genera Staphylococcus and Micrococcus was evaluated. Of 181 strains from culture collections, 95 of 95 Staphylococcus strains were lysed, and 79 of 79 Micrococcus strains were not lysed. The seven Planococcus strains were resistant. Clinical isolates (890) were tested with lysostaphin and for the ability to produce acid from glycerol in the presence of erythromycin. Overall agreement between the methods was 99.2%. All clinical Micrococcus strains (43) were resistant to lysostaphin, and all clinical Staphylococcus strains (847) were susceptible. Seven of the Staphylococcus strains did not produce acid from glycerol in the presence of erythromycin. This lysostaphin test provides results in 2 h. It is easier to perform than previously described lysostaphin lysis methods. It is also more rapid and accurate than the glycerol-erythromycin test. PMID:3519667

  1. Effect of choline supplementation on rapid weight loss and biochemical variables among female taekwondo and judo athletes.

    Science.gov (United States)

    Elsawy, Gehan; Abdelrahman, Osama; Hamza, Amr

    2014-03-27

    Taekwondo and judo competitions are divided into weight categories. Many athletes reduce their body mass a few days before competition in order to obtain a competitive advantage over lighter opponents. To achieve fast body mass reduction, athletes use a number of nutritional strategies, including choline supplementation. The goal of this study was to identify the effects of choline supplementation on body mass reduction and leptin levels among female taekwondo and judo athletes. Twenty-two female athletes (15 taekwondo and 7 judo athletes) were selected from different weight categories and divided into two groups, according to weight. The players in the experimental group took choline tablets for one week before a competition. The results revealed significant differences between pre- and post-competition measurements of leptin, free plasma choline, urine choline and urine malondialdehyde levels; body mass was also reduced in the post-competition measurements. In conclusion, choline supplementation could rapidly reduce body mass without any side effects on biochemical levels or static strength.

  2. Biochemical Removal of HAP Precursors From Coal

    Energy Technology Data Exchange (ETDEWEB)

    Olson, G.; Tucker, L.; Richards, J.

    1997-07-01

    This project addresses DOE`s interest in advanced concepts for controlling emissions of air toxics from coal-fired utility boilers. We are determining the feasibility of developing a biochemical process for the precombustion removal of substantial percentages of 13 inorganic hazardous air pollutant (HAP) precursors from coal. These HAP precursors are Sb, As, Be, Cd, Cr, Cl, Co, F, Pb, Hg, Mn, Ni, and Se. Although rapid physical coal cleaning is done routinely in preparation plants, biochemical processes for removal of HAP precursors from coal potentially offer advantages of deeper cleaning, more specificity, and less coal loss. Compared to chemical processes for coal cleaning, biochemical processes potentially offer lower costs and milder process conditions. Pyrite oxidizing bacteria, most notably Thiobacillusferrooxidans, are being evaluated in this project for their ability to remove HAP precursors from U.S. coals.

  3. Biochemical Removal of HAP Precursors From Coal

    International Nuclear Information System (INIS)

    Olson, G.; Tucker, L.; Richards, J.

    1997-07-01

    This project addresses DOE's interest in advanced concepts for controlling emissions of air toxics from coal-fired utility boilers. We are determining the feasibility of developing a biochemical process for the precombustion removal of substantial percentages of 13 inorganic hazardous air pollutant (HAP) precursors from coal. These HAP precursors are Sb, As, Be, Cd, Cr, Cl, Co, F, Pb, Hg, Mn, Ni, and Se. Although rapid physical coal cleaning is done routinely in preparation plants, biochemical processes for removal of HAP precursors from coal potentially offer advantages of deeper cleaning, more specificity, and less coal loss. Compared to chemical processes for coal cleaning, biochemical processes potentially offer lower costs and milder process conditions. Pyrite oxidizing bacteria, most notably Thiobacillusferrooxidans, are being evaluated in this project for their ability to remove HAP precursors from U.S. coals

  4. BACs-on-Beads Technology: A Reliable Test for Rapid Detection of Aneuploidies and Microdeletions in Prenatal Diagnosis

    Directory of Open Access Journals (Sweden)

    Sandra García-Herrero

    2014-01-01

    Full Text Available The risk of fetal aneuploidies is usually estimated based on high resolution ultrasound combined with biochemical determination of criterion in maternal blood, with invasive procedures offered to the population at risk. The purpose of this study was to investigate the effectiveness of a new rapid aneuploidy screening test on amniotic fluid (AF or chorionic villus (CV samples based on BACs-on-Beads (BoBs technology and to compare the results with classical karyotyping by Giemsa banding (G-banding of cultured cells in metaphase as the gold standard technique. The prenatal-BoBs kit was used to study aneuploidies involving chromosomes 13, 18, 21, X, and Y as well as nine microdeletion syndromes in 321 AF and 43 CV samples. G-banding of metaphase cultured cells was performed concomitantly for all prenatal samples. A microarray-based comparative genomic hybridization (aCGH was also carried out in a subset of samples. Prenatal-BoBs results were widely confirmed by classical karyotyping. Only six karyotype findings were not identified by Prenatal-BoBs, all of them due to the known limitations of the technique. In summary, the BACs-on-Beads technology was an accurate, robust, and efficient method for the rapid diagnosis of common aneuploidies and microdeletion syndromes in prenatal samples.

  5. Evaluation of rapid radiometric method for drug susceptibility testing of Mycobacterium tuberculosis

    International Nuclear Information System (INIS)

    Siddiqi, S.H.; Libonati, J.P.; Middlebrook, G.

    1981-01-01

    A total of 106 isolates of Mycobacterium tuberculosis were tested for drug susceptibility by the conventional 7H11 plate method and by a new rapid radiometric method using special 7H12 liquid medium with 14 C-labeled substrate. Results obtained by the two methods were compared for rapidity, sensitivity, and specificity of the new test method. There was 98% overall agreement between the results obtained by the two methods. Of a total of 424 drug tests, only 8 drug results did not agree, mostly in the case of streptomycin. This new procedure was found to be rapid, with 87% of the tests results reportable within 4 days and 98% reportable within 5 days as compared to the usual 3 weeks required with the conventional indirect susceptibility test method. The results of this preliminary study indicate that the rapid radiometric method seems to have the potential for routine laboratory use and merits further investigations

  6. Detection of gonococcal infection : pros and cons of a rapid test.

    Science.gov (United States)

    Vickerman, Peter; Peeling, Rosanna W; Watts, Charlotte; Mabey, David

    2005-01-01

    WHO estimates that 62 million cases of gonorrhea occur annually worldwide. Untreated infection can cause serious long-term complications, especially in women. In addition, Neisseria gonorrheae infection can facilitate HIV transmission, and babies born to infected mothers are at risk of ocular infection, which can lead to blindness. Where diagnostic facilities are lacking, gonorrhea can be treated syndromically. However, this inevitably leads to over-treatment, especially in women in whom the syndrome of vaginal discharge may be due not to N. gonorrheae infection but to several other more prevalent conditions. Over-treatment is a major concern because of widespread N. gonorrheae antibiotic resistance. Moreover, a high proportion of gonorrhea cases are asymptomatic and so do not present for syndromic management. Such cases will only be detected by screening tests. The gold standard test for the detection of N. gonorrheae is culture, which has high sensitivity and specificity. However, it requires well trained staff and its performance is affected by specimen transport conditions. Other options include microscopy and tests that detect gonococcal antigen or nucleic acid. Nucleic acid amplification tests (NAATs) have higher sensitivity and can be used on non-invasive samples (urine). However, they can cross-react with other Neisseria species and are expensive, requiring highly trained staff and sophisticated equipment. In settings where patients are asked to return for laboratory results, some infected patients never receive treatment as they fail to return for their test results. This reduction in treatment, and the possible onward transmission of N. gonorrheae during any delay in treatment, means that a rapid test of lower sensitivity may be more effective if it results in patients being treated at the initial visit. Indeed, even with the low sensitivity of currently available rapid tests (50-70%), modeling shows that they can outperform gold standard tests in

  7. Experimental Investigation Of Microbially Induced Corrosion Of Test Samples And Effect Of Self-assembled Hydrophobic Monolayers. Exposure Of Test Samples To Continuous Microbial Cultures, Chemical Analysis, And Biochemical Studies

    CERN Document Server

    Laurinavichius, K S

    1998-01-01

    Experimental Investigation Of Microbially Induced Corrosion Of Test Samples And Effect Of Self-assembled Hydrophobic Monolayers. Exposure Of Test Samples To Continuous Microbial Cultures, Chemical Analysis, And Biochemical Studies

  8. Development and Evaluation of a Rapid and Sensitive EBOV-RPA Test for Rapid Diagnosis of Ebola Virus Disease.

    Science.gov (United States)

    Yang, Mingjuan; Ke, Yuehua; Wang, Xuesong; Ren, Hang; Liu, Wei; Lu, Huijun; Zhang, Wenyi; Liu, Shiwei; Chang, Guohui; Tian, Shuguang; Wang, Lihua; Huang, Liuyu; Liu, Chao; Yang, Ruifu; Chen, Zeliang

    2016-06-01

    Confirming Ebola virus disease (EVD), a deadly infectious disease, requires real-time RT-PCR, which takes up to a few hours to yield results. Therefore, a rapid diagnostic assay is imperative for EVD diagnosis. A rapid nucleic acid test based on recombinase polymerase amplification (EBOV-RPA) was developed to specifically detect the 2014 outbreak strains. The EBOV-RPA assay was evaluated by testing samples from suspected EVD patients in parallel with RT-PCR. An EBOV-RPA, which could be completed in 20 min, was successfully developed. Of 271 patients who tested positive for Ebola virus by RT-PCR, 264 (sensitivity: 97%, 95% CI: 95.5-99.3%) were positive by EBOV-RPA; 101 of 104 patients (specificity: 97%, 95% CI: 93.9-100%) who tested negative by RT-PCR were also negative by EBOV-RPA. The sensitivity values for samples with a Ct value of RPA had significantly high Ct values. Results of external quality assessment samples with EBOV-RPA were 100%, consistent with those of RT-PCR. The EBOV-RPA assay showed 97% sensitivity and 97% specificity for all EVD samples tested, making it a rapid and sensitive test for EVD diagnosis.

  9. [Experimental rationale for the parameters of a rapid method for oxidase activity determination].

    Science.gov (United States)

    Butorina, N N

    2010-01-01

    Experimental rationale is provided for the parameters of a rapid (1-2-min) test to concurrently determine the oxidase activity of all bacteria grown on the membrane filter after water filtration. Oxidase reagents that are the aqueous solutions of tetramethyl-p-phenylenediamine dihydrochloride and demethyl-p-phenylenediamine dihydrochloride have been first ascertained to exert no effect on the viability and enzymatic activity of bacteria after one-hour contact. An algorithm has been improved for the rapid oxidase activity test: the allowable time for bacteria to contact oxidase reagents and procedures for minimizing the effect on bacterial biochemical activity following the contact. An accelerated method based on lactose medium with tergitol 7 and Endo agar has been devised to determine coliform bacteria, by applying the rapid oxidase test: the time of a final response is 18-24 hours. The method has been included into GOST 52426-2005.

  10. Comparison of avian biochemical test results with Abaxis VetScan and Hitachi 911 analyzers.

    Science.gov (United States)

    Greenacre, Cheryl B; Flatland, Bente; Souza, Marcy J; Fry, Michael M

    2008-12-01

    To compare results of clinical biochemical analysis using an Abaxis VetScan bench-top analyzer with reagents specifically marketed for avian use and a Hitachi 911 analyzer, plasma (both methods) and whole blood (VetScan method) samples from 20 clinically healthy Hispaniolan Amazon parrots (Amazona ventralis) were analyzed. Correlation between methods was very high (r = 0.9-1.0) for aspartate aminotransferase (AST), calcium, glucose, and uric acid; high (r = 0.7-0.89) for creatine kinase (CK), phosphorus, potassium, and total protein; moderate (r = 0.5-0.69) for globulin; and low (r = 0.3-0.49) for albumin and sodium. VetScan analyzer results for globulin, sodium, and uric acid had a constant negative bias (values below those from the Hitachi method). Based on difference plot analysis, results for AST, calcium, CK, and glucose are comparable. Because 16 of 20 values fell below the lower detection limit of the VetScan analyzer, bile acid data were excluded from analysis. By using a relatively small sample size (0.1 ml whole blood or plasma), the VetScan analyzer offers rapid in-house results, compact size, and ease of operation. For 4 of the most clinically relevant biochemical analytes used in avian medicine (AST, calcium, CK, glucose), it offers reliable values. For an additional 4 analytes (phosphorous, potassium, total protein, uric acid), establishing analyzer-specific reference intervals is recommended. Neither the VetScan nor the Hitachi method is recommended to assess albumin and globulin concentrations.

  11. Fast and Cost-Effective Biochemical Spectrophotometric Analysis of Solution of Insect “Blood” and Body Surface Elution

    Directory of Open Access Journals (Sweden)

    Aleksandra Łoś

    2018-05-01

    Full Text Available Using insect hemolymph (“blood” and insect body surface elutions, researchers can perform rapid and cheap biochemical analyses to determine the insect’s immunology status. The authors of this publication describe a detailed methodology for a quick marking of the concentration of total proteins and evaluation of the proteolytic system activity (acid, neutral, and alkaline proteases and protease inhibitors, as well as a methodology for quick “liver” tests in insects: alanine aminotransferase (ALT, aspartate aminotransferase (AST, alkaline phosphatase (ALP, and urea and glucose concentration analyses. The meaning and examples of an interpretation of the results of the presented methodology for biochemical parameter determination are described for the example of honey bees.

  12. Effect of autolysis on the specificity of bovine spongiform encephalopathy rapid tests

    Directory of Open Access Journals (Sweden)

    Caramelli Maria

    2010-07-01

    Full Text Available Abstract Background Routine rapid testing for Bovine Spongiform Encephalopathy (BSE has highlighted some problems with BSE rapid test performance, the most significant being the number of initially reactive samples and the false positive results on autolyzed tissue. This point is important for BSE active surveillance in risk populations, because tissue autolysis is often unavoidable in routine cases. A robust test suitable for use on field material is therefore needed. To date, very limited information regarding the effect of autolysis on the robustness of rapid tests has been documented; therefore, the National Reference Centre for Animal Encephalopathies (CEA rapid test laboratory selected 450 autolyzed and negative brain stem samples from fallen stock bovines older than 24 months to assess the specificity of four tests approved for BSE active surveillance: Biorad TeSeE, Enfer TSE version 2.0, Prionics® Check LIA, and IDEXX Herd Check BSE Antigen Kit EIA. The samples were graded according to the degree of autolysis and then dissected into five portions, four of which randomly assigned to processing by rapid tests and one to be available for confirmatory Western blot analysis. Findings The specificity of the four systems was 100% for all three grades of autolysis, while the percentage of initially reactive results was 0.00 (95%CI 0.00-0.82, 0.22 (95%CI 0.006-1.23, 0.44 (95%CI 0.05-1.60, and 0.89 (95%CI 0.24-2.26 for the Biorad TeSeE, the Prionics® Check LIA, the IDEXX Herd Check BSE and the Enfer TSE tests, respectively. No association with the degree of autolysis could be drawn. Conclusions The present study demonstrates that the four rapid tests can be considered well-running diagnostic tools regardless of tissue quality; nevertheless, the number of initial reactive samples reported for some systems must not be underestimated in routine testing. Furthermore the compliance with the reported performance can be guaranteed only when an ongoing

  13. Persistent negative illness perceptions despite long-term biochemical control of acromegaly: novel application of the drawing test

    NARCIS (Netherlands)

    Tiemensma, Jitske; Pereira, Alberto M.; Romijn, Johannes A.; Broadbent, Elizabeth; Biermasz, Nienke R.; Kaptein, Adrian A.

    2015-01-01

    Context and objective: Patients with acromegaly have persistent complaints despite long-term biochemical control. Drawings can be used to assess patients' perceptions about their disease. We aimed to explore the utility of the drawing test and its relation to illness perceptions and quality of life

  14. [Efficient and rapid non-test tube cloning of Jatropha curcas].

    Science.gov (United States)

    Wang, Zhao-Yu; Lin, Jing-Ming; Xu, Zeng-Fu

    2007-08-01

    To develop a new technique for efficient and rapid non-test tube cloning of the medicinal and energy- producing plant Jatropha curcas. Using the mini-stem fragment (2-3 cm) of Jatropha curcas with merely one axillary bud as the explant, the effect of an auxin IBA concentration on the plantlet regeneration was studied. When treated with 1 mg/LIBA for 1h, the explants showed the most rapid propagation. The mini-stem fragments high root regeneration ratio (96.7%), short root regeneration period (18.2-/+2.0 d), large number of new roots per explant (6.3-/+1.8), and long total root length (6.8-/+3.5 cm), demonstrating that this technique can be a simple and efficient method for rapid non-test tube cloning of Jatropha curcas of potential industrial value.

  15. Patho-TB test for the rapid diagnosis of pulmonary tuberculosis

    Directory of Open Access Journals (Sweden)

    Roya Alavi-Naini

    2009-09-01

    Full Text Available

    • BACKGROUND: Despite recent technologic improvements in identifying mycobacterium tuberculosis, we are still facing problems in rapid diagnosis of tuberculosis. The objective of this study is to determine the diagnostic value of a new rapid screening test (Patho-TB™ for diagnosis of pulmonary tuberculosis.
    • METHODS: Between September 2006 to August 2007, 178 patients were enrolled in the study who were finally classified into two groups; a group of documented pulmonary tuberculosis (n = 67 and a group of non-tuberculous pulmonary infection (n = 111. Patho-TB™ test, Ziehl-Neelsen staining and culture were done on all specimens.
    • RESULTS: Of all, 43 patients with pulmonary tuberculosis were sputum smear positive for acid fast bacilli and the rest were smear negative. Mean age of the patients was 59.8 ± 16.1 years and 44% of them were men. The results of Patho- TB™ test were positive in 40 of smear positive and 20 of smear negative tuberculous patients and 33 cases of nontuberculous control group. The sensitivity, specificity, positive and negative predictive values and accuracy of Patho- TB™ test were estimated 89.5%, 70.2%, 64.5%, 91.7% and 77.5%, respectively.
    • CONCLUSIONS: According to the present study it would be suggested that Patho-TB™ test could be a rapid and inexpensive method for diagnosis of pulmonary tuberculosis, given by its high sensitivity and negative predictive value. Concerning the high number of false positive results, using a confirmatory diagnostic procedure is mandatory.
    • KEYWORDS: Pulmonary Tuberculosis, Rapid Diagnosis, Mycobacterium Tuberculosis Antigens, Iran

  16. Lateral flow test strip based on colloidal selenium immunoassay for rapid detection of melamine in milk, milk powder, and animal feed

    Directory of Open Access Journals (Sweden)

    Wang ZZ

    2014-04-01

    Full Text Available Zhizeng Wang,1 Dejuan Zhi,2 Yang Zhao,1 Hailong Zhang,2 Xin Wang,2 Yi Ru,1 Hongyu Li1,2 1MOE Key Laboratory of Cell Activities and Stress Adaptations, School of Life Sciences, Lanzhou University, Lanzhou, People's Republic of China; 2Institute of Microbiology and Biochemical Pharmacy, School of Pharmaceutics, Lanzhou University, Lanzhou, People's Republic of China Abstract: Although high melamine (MEL intake has been proven to cause serious health problems, MEL is sometimes illegally added to milk products and animal feed, arousing serious food safety concerns. A satisfactory method of detecting MEL in onsite or in-home testing is in urgent need of development. This work aimed to explore a rapid, convenient, and cost-effective method of identifying MEL in milk products or other food by colloidal selenium-based lateral flow immunoassay. Colloidal selenium was synthesized by L-ascorbic acid to reduce seleninic acid at room temperature. After conjugation with a monoclonal antibody anti-MEL, a test strip was successfully prepared. The detection limit of the test strip reached 150 µg/kg, 1,000 µg/kg, and 800 µg/kg in liquid milk, milk powder, and animal feed, respectively. No cross-reactions with homologues cyanuric acid, cyanurodiamide, or ammelide were found. Moreover, the MEL test strip can remain stable after storage for 1 year at room temperature. Our results demonstrate that the colloidal selenium MEL test strip can detect MEL in adulterated milk products or animal feed conveniently, rapidly, and sensitively. In contrast with a colloidal gold MEL test strip, the colloidal selenium MEL test strip was easy to prepare and more cost-efficient. Keywords: melamine, selenium nanoparticles, test strip, milk, animal feed, dairy food

  17. The diagnostic sensitivity of dengue rapid test assays is significantly enhanced by using a combined antigen and antibody testing approach.

    Directory of Open Access Journals (Sweden)

    Scott R Fry

    2011-06-01

    Full Text Available BACKGROUND: Serological tests for IgM and IgG are routinely used in clinical laboratories for the rapid diagnosis of dengue and can differentiate between primary and secondary infections. Dengue virus non-structural protein 1 (NS1 has been identified as an early marker for acute dengue, and is typically present between days 1-9 post-onset of illness but following seroconversion it can be difficult to detect in serum. AIMS: To evaluate the performance of a newly developed Panbio® Dengue Early Rapid test for NS1 and determine if it can improve diagnostic sensitivity when used in combination with a commercial IgM/IgG rapid test. METHODOLOGY: The clinical performance of the Dengue Early Rapid was evaluated in a retrospective study in Vietnam with 198 acute laboratory-confirmed positive and 100 negative samples. The performance of the Dengue Early Rapid in combination with the IgM/IgG Rapid test was also evaluated in Malaysia with 263 laboratory-confirmed positive and 30 negative samples. KEY RESULTS: In Vietnam the sensitivity and specificity of the test was 69.2% (95% CI: 62.8% to 75.6% and 96% (95% CI: 92.2% to 99.8 respectively. In Malaysia the performance was similar with 68.9% sensitivity (95% CI: 61.8% to 76.1% and 96.7% specificity (95% CI: 82.8% to 99.9% compared to RT-PCR. Importantly, when the Dengue Early Rapid test was used in combination with the IgM/IgG test the sensitivity increased to 93.0%. When the two tests were compared at each day post-onset of illness there was clear differentiation between the antigen and antibody markers. CONCLUSIONS: This study highlights that using dengue NS1 antigen detection in combination with anti-glycoprotein E IgM and IgG serology can significantly increase the sensitivity of acute dengue diagnosis and extends the possible window of detection to include very early acute samples and enhances the clinical utility of rapid immunochromatographic testing for dengue.

  18. Software testing for evolutionary iterative rapid prototyping

    OpenAIRE

    Davis, Edward V., Jr.

    1990-01-01

    Approved for public release; distribution unlimited. Rapid prototyping is emerging as a promising software development paradigm. It provides a systematic and automatable means of developing a software system under circumstances where initial requirements are not well known or where requirements change frequently during development. To provide high software quality assurance requires sufficient software testing. The unique nature of evolutionary iterative prototyping is not well-suited for ...

  19. [Rapid test for detection of susceptibility to cefotaxime in Enterobacteriaceae].

    Science.gov (United States)

    Jiménez-Guerra, Gemma; Hoyos-Mallecot, Yannik; Rodríguez-Granger, Javier; Navarro-Marí, José María; Gutiérrez-Fernández, José

    In this work an "in house" rapid test based on the change in pH that is due to hydrolysis for detecting Enterobacteriaceae susceptible to cefotaxime is evaluated. The strains of Enterobacteriaceae from 1947 urine cultures were assessed using MicroScan panels and the "in house" test. This rapid test includes red phenol solution and cefotaxime. Using MicroScan panels, 499 Enterobacteriaceae isolates were evaluated, which included 27 isolates of Escherichia coli producing extended-spectrum beta-lactamases (ESBL), 16 isolates of Klebsiella pneumoniae ESBL and 1 isolate of Klebsiella oxytoca ESBL. The "in house" test offers the following values: sensitivity 98% and specificity 97%, with negative predictive value 100% and positive predictive value 78%. The "in house" test based on the change of pH is useful in our area for detecting presumptively cefotaxime-resistant Enterobacteriaceae strains. Copyright © 2016 Asociación Argentina de Microbiología. Publicado por Elsevier España, S.L.U. All rights reserved.

  20. Fast and Cost-Effective Biochemical Spectrophotometric Analysis of Solution of Insect “Blood” and Body Surface Elution

    OpenAIRE

    Aleksandra Łoś; Aneta Strachecka

    2018-01-01

    Using insect hemolymph (“blood”) and insect body surface elutions, researchers can perform rapid and cheap biochemical analyses to determine the insect’s immunology status. The authors of this publication describe a detailed methodology for a quick marking of the concentration of total proteins and evaluation of the proteolytic system activity (acid, neutral, and alkaline proteases and protease inhibitors), as well as a methodology for quick “liver” tests in insects: alanine aminotransferase ...

  1. Coagulation Tests and Selected Biochemical Analytes in Dairy Cows with Hepatic Lipidosis

    Directory of Open Access Journals (Sweden)

    S. Padilla-Arellanes

    2007-01-01

    Full Text Available The aim of this study was to determine the values and changes in conventional and optimised clotting tests, as well as in selected biochemical analytes during hepatic lipidosis in postpartum dairy cows. Ten healthy and ten Holstein cows with hepatic lipidosis were selected based upon clinical history, clinical examination, liver biopsy, flotation test and histological analysis of hepatic tissue. Prothrombin time (PT and partial thromboplastin time (PTT were determined in non-diluted and diluted blood plasma samples. Clotting times determined in diluted plasma samples were prolonged in cows with hepatic lipidosis and there was a difference in the PT value at both 50% and 25% plasma dilutions between both groups of animals (P = 0.004 and P = 0.001. Significant differences between healthy animals and cows with hepatic lipidosis were observed in blood serum values for free fatty acids (FFA, aspartate aminotransferase (AST and triacyglycerols (P = 0.001, P = 0.007 and P = 0.044, respectively. FFA and liver biopsy are better diagnostic indicators for hepatic lipidosis than coagulation tests. The optimised PT is prolonged in cows with hepatic lipidosis and can detect this alteration that cannot be appreciated using conventional PT test.

  2. Evaluation of a New and Rapid Serologic Test for Detecting Brucellosis: Brucella Coombs Gel Test.

    Science.gov (United States)

    Hanci, Hayrunisa; Igan, Hakan; Uyanik, Muhammet Hamidullah

    2017-01-01

    Many serological tests have been used for the diagnosis of human brucellosis. A new serological method is identified as Brucella Coombs gel test based on the principle of centrifugation gel system similar to the gel system used in blood group determination. In this system, if Brucella antibodies were present in the serum, antigen and antibody would remain as a pink complex on the gel. Otherwise, the pink Brucella antigens would precipitate at the bottom of the gel card system. In this study, we aimed to compare the Brucella Coombs gel test, a new, rapid screen and titration method for detection of non-agglutinating IgG with the Brucella Coombs test. For this study, a total of 88 serum samples were obtained from 45 healthy persons and 43 individuals who had clinical signs and symptoms of brucellosis. For each specimen, Rose Bengal test, standard agglutination test, Coombs test and Brucella Coombs gel test were carried out. Sensitivity and specificity of Brucella Coombs gel test were found as 100.0 and 82.2%, respectively. Brucella Coombs gel test can be used as a screening test with high sensitivity. By the help of pink Brucella antigen precipitation, the tests' evaluation is simple and objective. In addition, determination of Brucella antibody by rapid titration offers another important advantage.

  3. Evaluation of the OnSite malaria rapid test performance in Miandrivazo, Madagascar.

    Science.gov (United States)

    Ravaoarisoa, E; Andriamiandranoro, T; Raherinjafy, R; Jahevitra, M; Razanatsiorimalala, S; Andrianaranjaka, V; Randrianarivelojosia, M

    2017-10-01

    The performance of the malaria rapid diagnostic test OnSite-for detecting pan specific pLDH and Plasmodium falciparum specific HRP2 - was assessed during the malaria transmission peak period in Miandrivazo, in the southwestern part of Madagascar from April 20 to May 6, 2010. At the laboratory, the quality control OnSite Malaria Rapid Test according to the WHO/TDR/FIND method demonstrated that the test had good sensitivity. Of the 218 OnSite tests performed at the Miandrivazo Primary Health Center on patients with fever or a recent history of fever, four (1.8%, 95% CI: 0.6-4.9%) were invalid. Ninety four (43,1%) cases of malaria were confirmed by microscopy, of which 90 were P. falciparum malaria and 4 Plasmodium vivax malaria. With a Cohen's kappa coefficient of 0.94, the agreement between microscopy and OnSite is excellent. Compared with the rapid test CareStart™ commonly used within the public health structures in Madagascar, the sensitivity and specificity of the OnSite test were 97.9% and 96.8%.

  4. Evaluation of simple rapid HIV assays and development of national rapid HIV test algorithms in Dar es Salaam, Tanzania.

    Science.gov (United States)

    Lyamuya, Eligius F; Aboud, Said; Urassa, Willy K; Sufi, Jaffer; Mbwana, Judica; Ndugulile, Faustin; Massambu, Charles

    2009-02-18

    Suitable algorithms based on a combination of two or more simple rapid HIV assays have been shown to have a diagnostic accuracy comparable to double enzyme-linked immunosorbent assay (ELISA) or double ELISA with Western Blot strategies. The aims of this study were to evaluate the performance of five simple rapid HIV assays using whole blood samples from HIV-infected patients, pregnant women, voluntary counseling and testing attendees and blood donors, and to formulate an alternative confirmatory strategy based on rapid HIV testing algorithms suitable for use in Tanzania. Five rapid HIV assays: Determine HIV-1/2 (Inverness Medical), SD Bioline HIV 1/2 3.0 (Standard Diagnostics Inc.), First Response HIV Card 1-2.0 (PMC Medical India Pvt Ltd), HIV1/2 Stat-Pak Dipstick (Chembio Diagnostic System, Inc) and Uni-Gold HIV-1/2 (Trinity Biotech) were evaluated between June and September 2006 using 1433 whole blood samples from hospital patients, pregnant women, voluntary counseling and testing attendees and blood donors. All samples that were reactive on all or any of the five rapid assays and 10% of non-reactive samples were tested on a confirmatory Inno-Lia HIV I/II immunoblot assay (Immunogenetics). Three hundred and ninety samples were confirmed HIV-1 antibody positive, while 1043 were HIV negative. The sensitivity at initial testing of Determine, SD Bioline and Uni-Gold was 100% (95% CI; 99.1-100) while First Response and Stat-Pak had sensitivity of 99.5% (95% CI; 98.2-99.9) and 97.7% (95% CI; 95.7-98.9), respectively, which increased to 100% (95% CI; 99.1-100) on repeat testing. The initial specificity of the Uni-Gold assay was 100% (95% CI; 99.6-100) while specificities were 99.6% (95% CI; 99-99.9), 99.4% (95% CI; 98.8-99.7), 99.6% (95% CI; 99-99.9) and 99.8% (95% CI; 99.3-99.9) for Determine, SD Bioline, First Response and Stat-Pak assays, respectively. There was no any sample which was concordantly false positive in Uni-Gold, Determine and SD Bioline assays. An

  5. A Highly Sensitive Rapid Diagnostic Test for Chagas Disease That Utilizes a Recombinant Trypanosoma cruzi Antigen

    Science.gov (United States)

    Barfield, C. A.; Barney, R. S.; Crudder, C. H.; Wilmoth, J. L.; Stevens, D. S.; Mora-Garcia, S.; Yanovsky, M. J.; Weigl, B. H.; Yanovsky, J.

    2011-01-01

    Improved diagnostic tests for Chagas disease are urgently needed. A new lateral flow rapid test for Chagas disease is under development at PATH, in collaboration with Laboratorio Lemos of Argentina, which utilizes a recombinant antigen for detection of antibodies to Trypanosoma cruzi. To evaluate the performance of this test, 375 earlier characterized serum specimens from a region where Chagas is endemic were tested using a reference test (the Ortho T. cruzi ELISA, Johnson & Johnson), a commercially available rapid test (Chagas STAT-PAK, Chembio), and the PATH–Lemos rapid test. Compared to the composite reference tests, the PATH–Lemos rapid test demonstrated an optimal sensitivity of 99.5% and specificity of 96.8%, while the Chagas STAT-PAK demonstrated a sensitivity of 95.3% and specificity of 99.5%. These results indicate that the PATH–Lemos rapid test shows promise as an improved and reliable tool for screening and diagnosis of Chagas disease. PMID:21342808

  6. Biochemically enhanced methane production from coal

    Science.gov (United States)

    Opara, Aleksandra

    For many years, biogas was connected mostly with the organic matter decomposition in shallow sediments (e.g., wetlands, landfill gas, etc.). Recently, it has been realized that biogenic methane production is ongoing in many hydrocarbon reservoirs. This research examined microbial methane and carbon dioxide generation from coal. As original contributions methane production from various coal materials was examined in classical and electro-biochemical bench-scale reactors using unique, developed facultative microbial consortia that generate methane under anaerobic conditions. Facultative methanogenic populations are important as all known methanogens are strict anaerobes and their application outside laboratory would be problematic. Additional testing examined the influence of environmental conditions, such as pH, salinity, and nutrient amendments on methane and carbon dioxide generation. In 44-day ex-situ bench-scale batch bioreactor tests, up to 300,000 and 250,000 ppm methane was generated from bituminous coal and bituminous coal waste respectively, a significant improvement over 20-40 ppm methane generated from control samples. Chemical degradation of complex hydrocarbons using environmentally benign reagents, prior to microbial biodegradation and methanogenesis, resulted in dissolution of up to 5% bituminous coal and bituminous coal waste and up to 25% lignite in samples tested. Research results confirm that coal waste may be a significant underutilized resource that could be converted to useful fuel. Rapid acidification of lignite samples resulted in low pH (below 4.0), regardless of chemical pretreatment applied, and did not generate significant methane amounts. These results confirmed the importance of monitoring and adjusting in situ and ex situ environmental conditions during methane production. A patented Electro-Biochemical Reactor technology was used to supply electrons and electron acceptor environments, but appeared to influence methane generation in a

  7. Analysis of the theoretical model of the rapid chloride migration test

    NARCIS (Netherlands)

    Spiesz, P.; Brouwers, H.J.H.; Fisher, Gregor; Geiker, Metta Rica; Hededal, Ole; Ottosen, Lisbeth M.; Stang, Henrik

    2010-01-01

    Chloride ion diffusion coefficient in concrete is estimated very often by using electromigration tests, among which the Rapid Chloride Migration (RCM) test is becoming more and more popular. Nevertheless, this test receives much criticism due to lacks in its scientific background. In this paper the

  8. The cost of implementing rapid HIV testing in sexually transmitted disease clinics in the United States.

    Science.gov (United States)

    Eggman, Ashley A; Feaster, Daniel J; Leff, Jared A; Golden, Matthew R; Castellon, Pedro C; Gooden, Lauren; Matheson, Tim; Colfax, Grant N; Metsch, Lisa R; Schackman, Bruce R

    2014-09-01

    Rapid HIV testing in high-risk populations can increase the number of persons who learn their HIV status and avoid spending clinic resources to locate persons identified as HIV infected. We determined the cost to sexually transmitted disease (STD) clinics of point-of-care rapid HIV testing using data from 7 public clinics that participated in a randomized trial of rapid testing with and without brief patient-centered risk reduction counseling in 2010. Costs included counselor and trainer time, supplies, and clinic overhead. We applied national labor rates and test costs. We calculated median clinic start-up costs and mean cost per patient tested, and projected incremental annual costs of implementing universal rapid HIV testing compared with current testing practices. Criteria for offering rapid HIV testing and methods for delivering nonrapid test results varied among clinics before the trial. Rapid HIV testing cost an average of US $22/patient without brief risk reduction counseling and US $46/patient with counseling in these 7 clinics. Median start-up costs per clinic were US $1100 and US $16,100 without and with counseling, respectively. Estimated incremental annual costs per clinic of implementing universal rapid HIV testing varied by whether or not brief counseling is conducted and by current clinic testing practices, ranging from a savings of US $19,500 to a cost of US $40,700 without counseling and a cost of US $98,000 to US $153,900 with counseling. Universal rapid HIV testing in STD clinics with same-day results can be implemented at relatively low cost to STD clinics, if brief risk reduction counseling is not offered.

  9. Improving prescribing practices with rapid diagnostic tests (RDTs)

    DEFF Research Database (Denmark)

    Burchett, Helen E D; Leurent, Baptiste; Baiden, Frank

    2017-01-01

    OBJECTIVES: The overuse of antimalarial drugs is widespread. Effective methods to improve prescribing practice remain unclear. We evaluated the impact of 10 interventions that introduced rapid diagnostic tests for malaria (mRDTs) on the use of tests and adherence to results in different contexts...... packages, supervision, supplies and community sensitisation. OUTCOME MEASURES: Analysis explored variation in: (1) uptake of mRDTs (% febrile patients tested); (2) provider adherence to positive mRDTs (% Plasmodium falciparum positive prescribed/given Artemisinin Combination Treatment); (3) provider...... characteristics fitted with their own priorities. Goodness of fit of mRDTs with existing consultation and diagnostic practices appeared crucial to maximising the impact of mRDTs on care, as did prior familiarity with malaria testing; adequate human resources and supplies; possible alternative treatments for m...

  10. Improving the screening of blood donors with syphilis rapid diagnostic test (RDT) and rapid plasma reagin (RPR) in low- and middle-income countries (LMIC)

    DEFF Research Database (Denmark)

    Sarkodie, F.; Hassall, O.; Owusu-Dabo, E.

    2017-01-01

    BACKGROUND: Syphilis testing conventionally relies on a combination of non-treponemal and treponemal tests. The primary objective of this study was to describe the positive predictive value (PPV) of a screening algorithm in a combination of a treponemal rapid diagnostic test (RDT) and rapid plasma...

  11. [Benefits of using rapid HIV testing at the PMU-FLON walk-in clinic in Lausanne].

    Science.gov (United States)

    Gilgien, W; Aubert, J; Bischoff, T; Herzig, L; Perdrix, J

    2012-05-16

    Lab tests are frequently used in primary care to guide patient care. This is particularly the case when a severe disorder, or one that will affect patients' initial care, needs to be excluded rapidly. At the PMU-FLON walk-in clinic the use of HIV testing as recommended by the Swiss Office of Public Health was hampered by the delay in obtaining test results. This led us to introduce rapid HIV testing which provides results within 30 minutes. Following the first 250 tests the authors discuss the results as well as the benefits of rapid HIV testing in an urban walk-in clinic.

  12. Rapid Bedside Inactivation of Ebola Virus for Safe Nucleic Acid Tests

    DEFF Research Database (Denmark)

    Rosenstierne, Maiken Worsøe; Karlberg, Helen; Bragstad, Karoline

    2016-01-01

    Rapid bedside inactivation of Ebola virus would be a solution for the safety of medical and technical staff, risk containment, sample transport, and high-throughput or rapid diagnostic testing during an outbreak. We show that the commercially available Magna Pure lysis/binding buffer used...... for nucleic acid extraction inactivates Ebola virus. A rapid bedside inactivation method for nucleic acid tests is obtained by simply adding Magna Pure lysis/binding buffer directly into vacuum blood collection EDTA tubes using a thin needle and syringe prior to sampling. The ready-to-use inactivation vacuum...... tubes are stable for more than 4 months, and Ebola virus RNA is preserved in the Magna Pure lysis/binding buffer for at least 5 weeks independent of the storage temperature. We also show that Ebola virus RNA can be manually extracted from Magna Pure lysis/binding buffer-inactivated samples using...

  13. Acceptability of rapid oral fluid HIV testing among male injection drug users in Taiwan, 1997 and 2007.

    Science.gov (United States)

    Lyu, Shu-Yu; Morisky, Donald E; Yeh, Ching-Ying; Twu, Shiing-Jer; Peng, Eugene Yu-Chang; Malow, Robert M

    2011-04-01

    Rapid oral fluid HIV testing (rapid oral testing) is in the process of being adapted in Taiwan and elsewhere given its advantages over prior HIV testing methods. To guide this process, we examined the acceptability of rapid oral testing at two time points (i.e., 1997 and 2007) among one of the highest risk populations, male injection drug users (IDUs). For this purpose, an anonymous self-administered survey was completed by HIV-negative IDUs involved in the criminal justice system in 1997 (N (1)=137 parolees) and 2007 (N (2)=106 prisoners). A social marketing model helped guide the design of our questionnaire to assess the acceptability of rapid oral testing. This included assessing a new product, across four marketing dimensions: product, price, promotion, and place. Results revealed that in both 1997 and 2007, over 90% indicated that rapid oral testing would be highly acceptable, particularly if the cost was under US$6, and that a pharmacy would be the most appropriate and accessible venue for selling the rapid oral testing kits. The vast majority of survey respondents believed that the cost of rapid oral testing should be federally subsidized and that television and newspaper advertisements would be the most effective media to advertise for rapid oral testing. Both the 1997 and 2007 surveys suggested that rapid oral HIV testing would be particularly accepted in Taiwan by IDUs after release from the criminal justice system.

  14. Biochemical markers of bone turnover

    International Nuclear Information System (INIS)

    Kim, Deog Yoon

    1999-01-01

    Biochemical markers of bone turnover has received increasing attention over the past few years, because of the need for sensitivity and specific tool in the clinical investigation of osteoporosis. Bone markers should be unique to bone, reflect changes of bone less, and should be correlated with radiocalcium kinetics, histomorphometry, or changes in bone mass. The markers also should be useful in monitoring treatment efficacy. Although no bone marker has been established to meet all these criteria, currently osteocalcin and pyridinium crosslinks are the most efficient markers to assess the level of bone turnover in the menopausal and senile osteoporosis. Recently, N-terminal telopeptide (NTX), C-terminal telopeptide (CTX) and bone specific alkaline phosphatase are considered as new valid markers of bone turnover. Recent data suggest that CTX and free deoxypyridinoline could predict the subsequent risk of hip fracture of elderly women. Treatment of postmenopausal women with estrogen, calcitonin and bisphosphonates demonstrated rapid decrease of the levels of bone markers that correlated with the long-term increase of bone mass. Factors such as circadian rhythms, diet, age, sex, bone mass and renal function affect the results of biochemical markers and should be appropriately adjusted whenever possible. Each biochemical markers of bone turnover may have its own specific advantages and limitations. Recent advances in research will provide more sensitive and specific assays

  15. Diagnostic evaluation of rapid tests for scrub typhus in the Indian population is needed.

    Science.gov (United States)

    Shivalli, Siddharudha

    2016-05-12

    Owing to frequent outbreaks witnessed in different parts of the country in the recent past, scrub typhus is being described as a re-emerging infectious disease in India. Differentiating scrub typhus from other endemic diseases like malaria, leptospirosis, dengue fever, typhoid, etc. is difficult due to overlapping clinical features and a lower positivity for eschars in Asian populations. Hence, the diagnosis heavily relies on laboratory tests. Costs and the need of technical expertise limit the wide use of indirect immunoperoxidase or immunofluorescence assays, ELISA and PCR. The Weil-Felix test is the most commonly used and least expensive serological test, but lacks both sensitivity and specificity. Hence, the diagnosis of scrub typhus is often delayed or overlooked. With due consideration of the cost, rapidity, single test result and simplicity of interpretation, rapid diagnostic tests have come into vogue. However, evaluation of rapid diagnostic tests for scrub typhus in the Indian population is needed to justify or discourage their use. Research studies are needed to find the most suitable test in terms of the rapidity of the result, simplicity of the procedure, ease of interpretation and cost to be used in the Indian populace.

  16. Rapid high temperature field test method for evaluation of geothermal calcite scale inhibitors

    Energy Technology Data Exchange (ETDEWEB)

    Asperger, R.G.

    1982-08-01

    A test method is described which allows the rapid field testing of calcite scale inhibitors in high- temperature geothermal brines. Five commercial formulations, chosen on the basis of laboratory screening tests, were tested in brines with low total dissolved solids at ca 500 F. Four were found to be effective; of these, 2 were found to be capable of removing recently deposited scale. One chemical was tested in the full-flow brine line for 6 wks. It was shown to stop a severe surface scaling problem at the well's control valve, thus proving the viability of the rapid test method. (12 refs.)

  17. Evaluation of simple rapid HIV assays and development of national rapid HIV test algorithms in Dar es Salaam, Tanzania

    Directory of Open Access Journals (Sweden)

    Mbwana Judica

    2009-02-01

    Full Text Available Abstract Background Suitable algorithms based on a combination of two or more simple rapid HIV assays have been shown to have a diagnostic accuracy comparable to double enzyme-linked immunosorbent assay (ELISA or double ELISA with Western Blot strategies. The aims of this study were to evaluate the performance of five simple rapid HIV assays using whole blood samples from HIV-infected patients, pregnant women, voluntary counseling and testing attendees and blood donors, and to formulate an alternative confirmatory strategy based on rapid HIV testing algorithms suitable for use in Tanzania. Methods Five rapid HIV assays: Determine™ HIV-1/2 (Inverness Medical, SD Bioline HIV 1/2 3.0 (Standard Diagnostics Inc., First Response HIV Card 1–2.0 (PMC Medical India Pvt Ltd, HIV1/2 Stat-Pak Dipstick (Chembio Diagnostic System, Inc and Uni-Gold™ HIV-1/2 (Trinity Biotech were evaluated between June and September 2006 using 1433 whole blood samples from hospital patients, pregnant women, voluntary counseling and testing attendees and blood donors. All samples that were reactive on all or any of the five rapid assays and 10% of non-reactive samples were tested on a confirmatory Inno-Lia HIV I/II immunoblot assay (Immunogenetics. Results Three hundred and ninety samples were confirmed HIV-1 antibody positive, while 1043 were HIV negative. The sensitivity at initial testing of Determine, SD Bioline and Uni-Gold™ was 100% (95% CI; 99.1–100 while First Response and Stat-Pak had sensitivity of 99.5% (95% CI; 98.2–99.9 and 97.7% (95% CI; 95.7–98.9, respectively, which increased to 100% (95% CI; 99.1–100 on repeat testing. The initial specificity of the Uni-Gold™ assay was 100% (95% CI; 99.6–100 while specificities were 99.6% (95% CI; 99–99.9, 99.4% (95% CI; 98.8–99.7, 99.6% (95% CI; 99–99.9 and 99.8% (95% CI; 99.3–99.9 for Determine, SD Bioline, First Response and Stat-Pak assays, respectively. There was no any sample which was

  18. Repeat confirmatory testing for persons with discordant whole blood and oral fluid rapid HIV test results: findings from post marketing surveillance.

    Science.gov (United States)

    Wesolowski, Laura G; Mackellar, Duncan A; Ethridge, Steven F; Zhu, Julia H; Owen, S Michele; Sullivan, Patrick S

    2008-02-06

    Reactive oral fluid and whole blood rapid HIV tests must be followed with a confirmatory test (Western blot (WB), immunofluorescent assay (IFA) or approved nucleic acid amplification test (NAAT)). When the confirmatory result is negative or indeterminate (i.e. discordant with rapid result), repeat confirmatory testing should be conducted using a follow-up specimen. Previous reports have not described whether repeat testing adequately resolves the HIV-infection status of persons with discordant results. Post-marketing surveillance was conducted in 368 testing sites affiliated with 14 state and 2 city health departments from August 11, 2004 to June 30, 2005 and one health department through December 31, 2005. For persons with discordant results, data were collected on demographics, risk behaviors, HIV test results and specimen types. Persons with repeat confirmatory results were classified as HIV-infected or uninfected. Regression models were created to assess risk factors for not having repeat testing. Of 167,371 rapid tests conducted, 2589 (1.6%) were reactive: of these, 2417 (93%) had positive WB/IFA, 172 (7%) had negative or indeterminate WB/IFA. Of 89/172 (52%) persons with a repeat confirmatory test: 17 (19%) were HIV-infected, including 3 with indeterminate WB and positive NAAT; 72 (81%) were uninfected, including 12 with repeat indeterminate WB. Factors associated with HIV-infection included having an initial indeterminate WB/IFA (vs. negative) (ptest [adjusted OR 2.6, 95% CI (1.3, 4.9)]. Though only half of persons with discordant results had repeat confirmatory testing, of those who did, nearly one in five were HIV-infected. These findings underscore the need for rapid HIV testing programs to increase repeat confirmatory testing for persons with discordant results. Because of the lower sensitivity of oral fluid WBs, confirmatory testing following a reactive rapid test should be conducted using serum or plasma, when possible.

  19. Simple and rapid field tests for brucellosis in livestock

    NARCIS (Netherlands)

    Abdoel, Theresia; Dias, Isabel Travassos; Cardoso, Regina; Smits, Henk L.

    2008-01-01

    Four simple and rapid field tests for the serodiagnosis of brucellosis in cattle, goat, sheep and swine were developed. The performance of the assays was investigated using serum samples collected in Portugal from animals originating from herds with a defined sanitary status with respect to the

  20. Feasibility of utilizing the SD BIOLINE Onchocerciasis IgG4 rapid test in onchocerciasis surveillance in Senegal

    Science.gov (United States)

    Dieye, Yakou; Barrett, Kelsey L.; Gerth-Guyette, Emily; Di Giorgio, Laura; Golden, Allison; Faulx, Dunia; Kalnoky, Michael; Ndiaye, Marie Khemesse Ngom; Sy, Ngayo; Mané, Malang; Faye, Babacar; Sarr, Mamadou; Dioukhane, Elhadji Mamadou; Peck, Roger B.; Guinot, Philippe; de los Santos, Tala

    2017-01-01

    As effective onchocerciasis control efforts in Africa transition to elimination efforts, different diagnostic tools are required to support country programs. Senegal, with its long standing, successful control program, is transitioning to using the SD BIOLINE Onchocerciasis IgG4 (Ov16) rapid test over traditional skin snip microscopy. The aim of this study is to demonstrate the feasibility of integrating the Ov16 rapid test into onchocerciasis surveillance activities in Senegal, based on the following attributes of acceptability, usability, and cost. A cross-sectional study was conducted in 13 villages in southeastern Senegal in May 2016. Individuals 5 years and older were invited to participate in a demographic questionnaire, an Ov16 rapid test, a skin snip biopsy, and an acceptability interview. Rapid test technicians were interviewed and a costing analysis was conducted. Of 1,173 participants, 1,169 (99.7%) agreed to the rapid test while 383 (32.7%) agreed to skin snip microscopy. The sero-positivity rate of the rapid test among those tested was 2.6% with zero positives 10 years and younger. None of the 383 skin snips were positive for Ov microfilaria. Community members appreciated that the rapid test was performed quickly, was not painful, and provided reliable results. The total costs for this surveillance activity was $22,272.83, with a cost per test conducted at $3.14 for rapid test, $7.58 for skin snip microscopy, and $13.43 for shared costs. If no participants had refused skin snip microscopy, the total cost per method with shared costs would have been around $16 per person tested. In this area with low onchocerciasis sero-positivity, there was high acceptability and perceived value of the rapid test by community members and technicians. This study provides evidence of the feasibility of implementing the Ov16 rapid test in Senegal and may be informative to other country programs transitioning to Ov16 serologic tools. PMID:28972982

  1. Feasibility of utilizing the SD BIOLINE Onchocerciasis IgG4 rapid test in onchocerciasis surveillance in Senegal.

    Directory of Open Access Journals (Sweden)

    Yakou Dieye

    2017-10-01

    Full Text Available As effective onchocerciasis control efforts in Africa transition to elimination efforts, different diagnostic tools are required to support country programs. Senegal, with its long standing, successful control program, is transitioning to using the SD BIOLINE Onchocerciasis IgG4 (Ov16 rapid test over traditional skin snip microscopy. The aim of this study is to demonstrate the feasibility of integrating the Ov16 rapid test into onchocerciasis surveillance activities in Senegal, based on the following attributes of acceptability, usability, and cost. A cross-sectional study was conducted in 13 villages in southeastern Senegal in May 2016. Individuals 5 years and older were invited to participate in a demographic questionnaire, an Ov16 rapid test, a skin snip biopsy, and an acceptability interview. Rapid test technicians were interviewed and a costing analysis was conducted. Of 1,173 participants, 1,169 (99.7% agreed to the rapid test while 383 (32.7% agreed to skin snip microscopy. The sero-positivity rate of the rapid test among those tested was 2.6% with zero positives 10 years and younger. None of the 383 skin snips were positive for Ov microfilaria. Community members appreciated that the rapid test was performed quickly, was not painful, and provided reliable results. The total costs for this surveillance activity was $22,272.83, with a cost per test conducted at $3.14 for rapid test, $7.58 for skin snip microscopy, and $13.43 for shared costs. If no participants had refused skin snip microscopy, the total cost per method with shared costs would have been around $16 per person tested. In this area with low onchocerciasis sero-positivity, there was high acceptability and perceived value of the rapid test by community members and technicians. This study provides evidence of the feasibility of implementing the Ov16 rapid test in Senegal and may be informative to other country programs transitioning to Ov16 serologic tools.

  2. Feasibility of utilizing the SD BIOLINE Onchocerciasis IgG4 rapid test in onchocerciasis surveillance in Senegal.

    Science.gov (United States)

    Dieye, Yakou; Storey, Helen L; Barrett, Kelsey L; Gerth-Guyette, Emily; Di Giorgio, Laura; Golden, Allison; Faulx, Dunia; Kalnoky, Michael; Ndiaye, Marie Khemesse Ngom; Sy, Ngayo; Mané, Malang; Faye, Babacar; Sarr, Mamadou; Dioukhane, Elhadji Mamadou; Peck, Roger B; Guinot, Philippe; de Los Santos, Tala

    2017-10-01

    As effective onchocerciasis control efforts in Africa transition to elimination efforts, different diagnostic tools are required to support country programs. Senegal, with its long standing, successful control program, is transitioning to using the SD BIOLINE Onchocerciasis IgG4 (Ov16) rapid test over traditional skin snip microscopy. The aim of this study is to demonstrate the feasibility of integrating the Ov16 rapid test into onchocerciasis surveillance activities in Senegal, based on the following attributes of acceptability, usability, and cost. A cross-sectional study was conducted in 13 villages in southeastern Senegal in May 2016. Individuals 5 years and older were invited to participate in a demographic questionnaire, an Ov16 rapid test, a skin snip biopsy, and an acceptability interview. Rapid test technicians were interviewed and a costing analysis was conducted. Of 1,173 participants, 1,169 (99.7%) agreed to the rapid test while 383 (32.7%) agreed to skin snip microscopy. The sero-positivity rate of the rapid test among those tested was 2.6% with zero positives 10 years and younger. None of the 383 skin snips were positive for Ov microfilaria. Community members appreciated that the rapid test was performed quickly, was not painful, and provided reliable results. The total costs for this surveillance activity was $22,272.83, with a cost per test conducted at $3.14 for rapid test, $7.58 for skin snip microscopy, and $13.43 for shared costs. If no participants had refused skin snip microscopy, the total cost per method with shared costs would have been around $16 per person tested. In this area with low onchocerciasis sero-positivity, there was high acceptability and perceived value of the rapid test by community members and technicians. This study provides evidence of the feasibility of implementing the Ov16 rapid test in Senegal and may be informative to other country programs transitioning to Ov16 serologic tools.

  3. Evaluation of microscopy and rapid diagnostic tests in screening ...

    African Journals Online (AJOL)

    Malaria is a life-threatening disease caused by the protozoa of the genus Plasmodium. Infection of individual is through the bites of infected female Anopheles mosquitoes. This study evaluated the performance of microscopy and rapid diagnostic tests (RDTs) in diagnosing malaria. A total of 400 clinically suspected malaria ...

  4. Rapid screening test for porphyria diagnosis using fluorescence spectroscopy

    Science.gov (United States)

    Lang, A.; Stepp, H.; Homann, C.; Hennig, G.; Brittenham, G. M.; Vogeser, M.

    2015-07-01

    Porphyrias are rare genetic metabolic disorders, which result from deficiencies of enzymes in the heme biosynthesis pathway. Depending on the enzyme defect, different types of porphyrins and heme precursors accumulate for the different porphyria diseases in erythrocytes, liver, blood plasma, urine and stool. Patients with acute hepatic porphyrias can suffer from acute neuropathic attacks, which can lead to death when undiagnosed, but show only unspecific clinical symptoms such as abdominal pain. Therefore, in addition to chromatographic methods, a rapid screening test is required to allow for immediate identification and treatment of these patients. In this study, fluorescence spectroscopic measurements were conducted on blood plasma and phantom material, mimicking the composition of blood plasma of porphyria patients. Hydrochloric acid was used to differentiate the occurring porphyrins (uroporphyrin-III and coproporphyrin-III) spectroscopically despite their initially overlapping excitation spectra. Plasma phantom mixtures were measured using dual wavelength excitation and the corresponding concentrations of uroporphyrin-III and coproporphyrin-III were determined. Additionally, three plasma samples of porphyria patients were examined and traces of coproporphyrin-III and uroporphyrin-III were identified. This study may therefore help to establish a rapid screening test method with spectroscopic differentiation of the occurring porphyrins, which consequently allows for the distinction of different porphyrias. This may be a valuable tool for clinical porphyria diagnosis and rapid or immediate treatment.

  5. Test plan for demonstration of Rapid Transuranic Monitoring Laboratory

    International Nuclear Information System (INIS)

    McIsaac, C.V.; Sill, C.W.; Gehrke, R.J.; Killian, E.W.; Watts, K.D.

    1993-06-01

    This plan describes tests to demonstrate the capability of the Rapid Transuranic Monitoring Laboratory (RTML) to monitor airborne alpha-emitting radionuclides and analyze soil, smear, and filter samples for alpha- and gamma-emitting radionuclides under field conditions. The RTML will be tested during June 1993 at a site adjacent to the Cold Test Pit at the Radioactive Waste Management Complex at the Idaho National Engineering Laboratory. Measurement systems installed in the RTML that will be demonstrated include two large-area ionization chamber alpha spectrometers, an x-ray/gamma-ray spectrometer, and four alpha continuous air monitors. Test objectives, requirements for data quality, experimental apparatus and procedures, and safety and logistics issues are described

  6. Rapid-cycle testing cuts bed turnaround by 85%.

    Science.gov (United States)

    2004-11-01

    You can use rapid-cycle testing to try out new approaches to overcrowding much more frequently than with more traditional process improvement strategies. Improving bed turnaround notification can yield dramatic improvements. Telling staff they have to try a new process only for three days makes it easier to gain buy-in. Look for old policies that are no longer needed, yet continue to keep your staff bogged down.

  7. Accurate atom-mapping computation for biochemical reactions.

    Science.gov (United States)

    Latendresse, Mario; Malerich, Jeremiah P; Travers, Mike; Karp, Peter D

    2012-11-26

    The complete atom mapping of a chemical reaction is a bijection of the reactant atoms to the product atoms that specifies the terminus of each reactant atom. Atom mapping of biochemical reactions is useful for many applications of systems biology, in particular for metabolic engineering where synthesizing new biochemical pathways has to take into account for the number of carbon atoms from a source compound that are conserved in the synthesis of a target compound. Rapid, accurate computation of the atom mapping(s) of a biochemical reaction remains elusive despite significant work on this topic. In particular, past researchers did not validate the accuracy of mapping algorithms. We introduce a new method for computing atom mappings called the minimum weighted edit-distance (MWED) metric. The metric is based on bond propensity to react and computes biochemically valid atom mappings for a large percentage of biochemical reactions. MWED models can be formulated efficiently as Mixed-Integer Linear Programs (MILPs). We have demonstrated this approach on 7501 reactions of the MetaCyc database for which 87% of the models could be solved in less than 10 s. For 2.1% of the reactions, we found multiple optimal atom mappings. We show that the error rate is 0.9% (22 reactions) by comparing these atom mappings to 2446 atom mappings of the manually curated Kyoto Encyclopedia of Genes and Genomes (KEGG) RPAIR database. To our knowledge, our computational atom-mapping approach is the most accurate and among the fastest published to date. The atom-mapping data will be available in the MetaCyc database later in 2012; the atom-mapping software will be available within the Pathway Tools software later in 2012.

  8. Evaluation of a rapid radiometric differentiation test for the Mycobacterium tuberculosis complex by selective inhibition with p-nitro-alpha-acetylamino-beta-hydroxypropiophenone

    International Nuclear Information System (INIS)

    Laszlo, A.; Siddiqi, S.H.

    1984-01-01

    This study is an evaluation of a rapid technique for the differentiation of the Mycobacterium tuberculosis complex from other mycobacteria, using p-nitro-alpha-acetylamino-beta- hydroxypropiophenone (NAP) as a selective inhibitory agent. A total of 416 coded cultures, 234 cultures belonging to the M. tuberculosis complex and 182 cultures belonging to 35 other mycobacterial species, were tested in two laboratories for p-nitro-alpha-acetylamino-beta- hydroxypropiophenone inhibition to concentrations of 5 and 10 micrograms of NAP per ml in Middlebrook 7H12 liquid medium. Two testing modes were compared: the indirect, in which a large bacterial inoculum was used from an isolated culture on a solid medium, and the direct, which used a small inoculum from 7H12 medium. A decrease or no increase in daily 14 CO 2 output as measured by a BACTEC system was considered evidence of inhibition. The data presented show that a concentration of 5 micrograms of NAP per ml can effectively separate the M. tuberculosis complex from other mycobacterial species in 4 to 6 days. The direct test data show that, unlike other conventional biochemical tests, it does not require a heavy inoculum of mycobacteria and can therefore be performed soon after growth is detected by the radiometric method

  9. Evaluation of the diagnostic performance and operational characteristics of four rapid immunochromatographic syphilis tests in Burkina Faso.

    Science.gov (United States)

    Bocoum, Fadima Yaya; Ouédraogo, Henri; Tarnagda, Grissoum; Kiba, Alice; Tiendrebeogo, Simon; Bationo, Fabrice; Liestman, Benjamin; Diagbouga, Serge; Zarowsky, Christina; Traoré, Ramata Ouédraogo; Kouanda, Séni

    2015-06-01

    Little information is available on the rapid diagnostic testing for syphilis in Burkina Faso. The objectives of the study were (i) to assess the sensitivity and specificity of four on site rapid tests in comparison with Treponema pallidum haemagglutination assay (TPHA) as a gold standard and (ii) to evaluate the operational characteristics of those tests among health workers in a maternity unit. Four rapid syphilis tests commercially available in Burkina Faso were evaluated using archived serum samples and Treponema pallidum hemagglutination assay (TPHA) as the gold standard. Blood samples were collected between November 2011 and June 2012 from blood donors at the Regional Blood Transfusion Center of Ouagadougou. The sensitivity and specificity of the tests were calculated. Evaluation of operational characteristics such as clarity of pamphlet, complexity of technique, duration, was conducted in a first-level healthcare center with health workers in maternity unit. Alere DetermineTM Syphilis was the most sensitive of the four rapid syphilis tests evaluated. It was followed by SD Bioline Syphilis 3.0, Cypress Diagnostics Syphilis Quick test and Accu-Tell ® Rapid Anti-TP, which was the least sensitive. The four tests demonstrated a good diagnostic specificity for syphilis (95-98%), and healthcare workers found them easy to use. The study allowed confirming the good performance of three of four rapid syphilis tests in Burkina Faso. More research will be conducted to assess the feasibility of introducing selected rapid tests for syphilis in antenatal care services.

  10. Rapid antigen detection test for respiratory syncytial virus diagnosis as a diagnostic tool.

    Science.gov (United States)

    Mesquita, Flávio da Silva; Oliveira, Danielle Bruna Leal de; Crema, Daniela; Pinez, Célia Miranda Nunes; Colmanetti, Thaís Cristina; Thomazelli, Luciano Matsumia; Gilio, Alfredo Elias; Vieira, Sandra Elisabeth; Martinez, Marina Baquerizo; Botosso, Viviane Fongaro; Durigon, Edison Luiz

    The aim of this study was to evaluate the QuickVue ® RSV Test Kit (QUIDEL Corp, CA, USA) as a screening tool for respiratory syncytial virus in children with acute respiratory disease in comparison with the indirect immunofluorescence assay as gold standard. In Brazil, rapid antigen detection tests for respiratory syncytial virus are not routinely utilized as a diagnostic tool, except for the diagnosis of dengue and influenza. The authors retrospectively analyzed 486 nasopharyngeal aspirate samples from children under age 5 with acute respiratory infection, between December 2013 and August 2014, the samples were analyzed by indirect immunofluorescence assay and QuickVue ® RSV Test kit. Samples with discordant results were analyzed by real time PCR and nucleotide sequencing. From 313 positive samples by immunofluorescence assays, 282 (90%) were also positive by the rapid antigen detection test, two were positive only by rapid antigen detection test, 33 were positive only by immunofluorescence assays, and 171 were positive by both methods. The 35 samples with discordant results were analyzed by real time PCR; the two samples positive only by rapid antigen detection test and the five positive only by immunofluorescence assays were also positive by real time PCR. There was no relation between the negativity by QuickVue ® RSV Test and viral load or specific strain. The QuickVue ® RSV Test showed sensitivity of 90%, specificity of 98.8%, predictive positive value of 99.3%, and negative predictive value of 94.6%, with accuracy of 93.2% and agreement κ index of 0.85 in comparison to immunofluorescence assay. This study demonstrated that the QuickVue ® RSV Test Kit can be effective in early detection of Respiratory syncytial virus in nasopharyngeal aspirate and is reliable for use as a diagnostic tool in pediatrics. Copyright © 2016 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  11. Rapid antigen detection test for respiratory syncytial virus diagnosis as a diagnostic tool,

    Directory of Open Access Journals (Sweden)

    Flávio da Silva Mesquita

    Full Text Available Abstract Objective: The aim of this study was to evaluate the QuickVue® RSV Test Kit (QUIDEL Corp, CA, USA as a screening tool for respiratory syncytial virus in children with acute respiratory disease in comparison with the indirect immunofluorescence assay as gold standard. In Brazil, rapid antigen detection tests for respiratory syncytial virus are not routinely utilized as a diagnostic tool, except for the diagnosis of dengue and influenza. Methods: The authors retrospectively analyzed 486 nasopharyngeal aspirate samples from children under age 5 with acute respiratory infection, between December 2013 and August 2014, the samples were analyzed by indirect immunofluorescence assay and QuickVue® RSV Test kit. Samples with discordant results were analyzed by real time PCR and nucleotide sequencing. Results: From 313 positive samples by immunofluorescence assays, 282 (90% were also positive by the rapid antigen detection test, two were positive only by rapid antigen detection test, 33 were positive only by immunofluorescence assays, and 171 were positive by both methods. The 35 samples with discordant results were analyzed by real time PCR; the two samples positive only by rapid antigen detection test and the five positive only by immunofluorescence assays were also positive by real time PCR. There was no relation between the negativity by QuickVue® RSV Test and viral load or specific strain. The QuickVue® RSV Test showed sensitivity of 90%, specificity of 98.8%, predictive positive value of 99.3%, and negative predictive value of 94.6%, with accuracy of 93.2% and agreement κ index of 0.85 in comparison to immunofluorescence assay. Conclusions: This study demonstrated that the QuickVue® RSV Test Kit can be effective in early detection of Respiratory syncytial virus in nasopharyngeal aspirate and is reliable for use as a diagnostic tool in pediatrics.

  12. Comparison of a new rapid plasma reagin card test with the standard rapid plasma reagin 18-mm circle card test and the venereal disease research laboratory slide test for serodiagnosis of syphilis.

    OpenAIRE

    Hambie, E A; Larsen, S A; Perryman, M W; Pettit, D E; Mullally, R L; Whittington, W

    1983-01-01

    The rapid plasma reagin (RPR) card test manufactured by Beckman Instruments, Inc., was compared, qualitatively and quantitatively, with the Venereal Disease Research Laboratory (VDRL) slide test and the standard RPR 18-mm circle card tests for the serodiagnosis of syphilis. Sera from 638 individuals were used in this study. Two pilot lots and two production lots of antigen were submitted by Beckman Instruments, Inc., for evaluation. Qualitative agreement among the three RPR card tests was 98....

  13. Hypervapotron flow testing with rapid prototype models

    International Nuclear Information System (INIS)

    Driemeyer, D.; Hellwig, T.; Kubik, D.; Langenderfer, E.; Mantz, H.; McSmith, M.; Jones, B.; Butler, J.

    1995-01-01

    A flow test model of the inlet section of a three channel hypervapotron plate that has been proposed as a heat sink in the ITER divertor was prepared using a rapid prototyping stereolithography process that is widely used for component development in US industry. An existing water flow loop at the University of Illinois is being used for isothermal flow tests to collect pressure drop data for comparison with proposed vapotron friction factor correlations. Differential pressure measurements are taken, across the test section inlet manifold, the vapotron channel (about a seven inch length), the outlet manifold and the inlet-to-outlet. The differential pressures are currently measured with manometers. Tests were conducted at flow velocities from 1--10 m/s to cover the full range of ITER interest. A tap was also added for a small hypodermic needle to inject dye into the flow channel at several positions to examine the nature of the developing flow field at the entrance to the vapotron section. Follow-on flow tests are planned using a model with adjustable flow channel dimensions to permit more extensive pressure drop data to be collected. This information will be used to update vapotron design correlations for ITER

  14. The Rapid Integration and Test Environment - A Process for Achieving Software Test Acceptance

    OpenAIRE

    Jack, Rick

    2010-01-01

    Proceedings Paper (for Acquisition Research Program) Approved for public release; distribution unlimited. The Rapid Integration and Test Environment (RITE) initiative, implemented by the Program Executive Office, Command, Control, Communications, Computers and Intelligence, Command and Control Program Office (PMW-150), was born of necessity. Existing processes for requirements definition and management, as well as those for software development, did not consistently deliver high-qualit...

  15. The effects of surface treatments on rapid chloride permeability tests

    KAUST Repository

    Yoon, Seyoon

    2012-08-01

    Surface treatments are commonly applied to improve the chloride resistance of concrete structures exposed to saline environments. Information on chloride ingress to surface-treated concrete is mostly provided by application of the rapid chloride permeability test (RCPT); this test is short in duration and provides rapid results. This study presents a numerical formulation, based on the extended Nernst-Plank/Poisson (NPP) equation, to model the effect of the surface treatment on a sample tested by RCPT. Predictions of the model are compared to experimental measurements. The simulations show that the results from RCPT, in terms of ionic profiles and measurement of the electric field, are dependent on the effectiveness of surface treatments. During RCPT, highly effective surface treatments cause both cations and anions to flocculate at the interface between the surface treatment and the concrete, creating a local electric field. Our numerical model includes these phenomena and presents a methodology to obtain more accurate diffusivities of the surface-treated- concrete from RCPT. © 2012 Elsevier B.V. All rights reserved.

  16. The effects of surface treatments on rapid chloride permeability tests

    KAUST Repository

    Yoon, Seyoon; Oh, Sang-gyun; Ha, Juyoung; Monteiro, Paulo M.

    2012-01-01

    Surface treatments are commonly applied to improve the chloride resistance of concrete structures exposed to saline environments. Information on chloride ingress to surface-treated concrete is mostly provided by application of the rapid chloride permeability test (RCPT); this test is short in duration and provides rapid results. This study presents a numerical formulation, based on the extended Nernst-Plank/Poisson (NPP) equation, to model the effect of the surface treatment on a sample tested by RCPT. Predictions of the model are compared to experimental measurements. The simulations show that the results from RCPT, in terms of ionic profiles and measurement of the electric field, are dependent on the effectiveness of surface treatments. During RCPT, highly effective surface treatments cause both cations and anions to flocculate at the interface between the surface treatment and the concrete, creating a local electric field. Our numerical model includes these phenomena and presents a methodology to obtain more accurate diffusivities of the surface-treated- concrete from RCPT. © 2012 Elsevier B.V. All rights reserved.

  17. Application tests of a new-type LNG rapid gasification unit

    Directory of Open Access Journals (Sweden)

    Ping Yan

    2017-01-01

    Full Text Available Liquefied natural gas (LNG is stored under low temperature and high pressure. It has to be gasified before it is used. Therefore, LNG gasification unit is essential and it is vital to the high-efficiency utilization of LNG. In this paper, a new-type LNG rapid gasification unit was developed. Adopted in this unit are some innovative technologies authorized with the national patent of invention, such as the umbrella-shape gas flow circle unit, the flue gas circulation system and the water feeding system, which help to guarantee its operation safety and increase its operation efficiency. After it was justified in lab test, the unit for industrial application was designed and manufactured and then tested to verify its design rationality. The results show that the new-type LNG rapid gasification unit meets the design requirements in the aspect of efficiency, exhaust gas loss, radiation loss and fuel gas consumption rate; at a load of 1800–2200 m3/h, its efficiency is over 95%; at a load of 1976.0 m3/h which is close to the design value of 2000 m3/h, its efficiency is 96.34% or even up to 2800 m3/h. This new-type LNG rapid gasification unit is adaptable to a large range of loads and can adapt to the rapid increase of external load. Its fuel gas consumption rate is only 1.5%, which is in the range of energy conservation. It presents the advantages of high heating efficiency, rapid startup, high gasification rate, compact structure, small land occupation and invulnerability to the environment, therefore, it is applicable to the middle and small independent regions which cannot be connected to the natural gas supply pipeline networks due to various reasons.

  18. Application of Rapid Prototyping Methods to High-Speed Wind Tunnel Testing

    Science.gov (United States)

    Springer, A. M.

    1998-01-01

    This study was undertaken in MSFC's 14-Inch Trisonic Wind Tunnel to determine if rapid prototyping methods could be used in the design and manufacturing of high speed wind tunnel models in direct testing applications, and if these methods would reduce model design/fabrication time and cost while providing models of high enough fidelity to provide adequate aerodynamic data, and of sufficient strength to survive the test environment. Rapid prototyping methods utilized to construct wind tunnel models in a wing-body-tail configuration were: fused deposition method using both ABS plastic and PEEK as building materials, stereolithography using the photopolymer SL-5170, selective laser sintering using glass reinforced nylon, and laminated object manufacturing using plastic reinforced with glass and 'paper'. This study revealed good agreement between the SLA model, the metal model with an FDM-ABS nose, an SLA nose, and the metal model for most operating conditions, while the FDM-ABS data diverged at higher loading conditions. Data from the initial SLS model showed poor agreement due to problems in post-processing, resulting in a different configuration. A second SLS model was tested and showed relatively good agreement. It can be concluded that rapid prototyping models show promise in preliminary aerodynamic development studies at subsonic, transonic, and supersonic speeds.

  19. Dilution testing using rapid diagnostic tests in a HIV diagnostic algorithm: a novel alternative for confirmation testing in resource limited settings.

    Science.gov (United States)

    Shanks, Leslie; Siddiqui, M Ruby; Abebe, Almaz; Piriou, Erwan; Pearce, Neil; Ariti, Cono; Masiga, Johnson; Muluneh, Libsework; Wazome, Joseph; Ritmeijer, Koert; Klarkowski, Derryck

    2015-05-14

    Current WHO testing guidelines for resource limited settings diagnose HIV on the basis of screening tests without a confirmation test due to cost constraints. This leads to a potential risk of false positive HIV diagnosis. In this paper, we evaluate the dilution test, a novel method for confirmation testing, which is simple, rapid, and low cost. The principle of the dilution test is to alter the sensitivity of a rapid diagnostic test (RDT) by dilution of the sample, in order to screen out the cross reacting antibodies responsible for falsely positive RDT results. Participants were recruited from two testing centres in Ethiopia where a tiebreaker algorithm using 3 different RDTs in series is used to diagnose HIV. All samples positive on the initial screening RDT and every 10th negative sample underwent testing with the gold standard and dilution test. Dilution testing was performed using Determine™ rapid diagnostic test at 6 different dilutions. Results were compared to the gold standard of Western Blot; where Western Blot was indeterminate, PCR testing determined the final result. 2895 samples were recruited to the study. 247 were positive for a prevalence of 8.5 % (247/2895). A total of 495 samples underwent dilution testing. The RDT diagnostic algorithm misclassified 18 samples as positive. Dilution at the level of 1/160 was able to correctly identify all these 18 false positives, but at a cost of a single false negative result (sensitivity 99.6 %, 95 % CI 97.8-100; specificity 100 %, 95 % CI: 98.5-100). Concordance between the gold standard and the 1/160 dilution strength was 99.8 %. This study provides proof of concept for a new, low cost method of confirming HIV diagnosis in resource-limited settings. It has potential for use as a supplementary test in a confirmatory algorithm, whereby double positive RDT results undergo dilution testing, with positive results confirming HIV infection. Negative results require nucleic acid testing to rule out false

  20. [The social marketing models and policy advices for HIV rapid testing initiated by non-govermental organization].

    Science.gov (United States)

    Liu, H; Cai, L P; Xue, H; Zhao, Y; Wu, D; Zhang, D P; Yin, W Y; Sun, J P

    2016-10-06

    Currently, a growing number of community-based organizations are providing rapid HIV testing service in various forms, some people with specific needs also purchase HIV rapid test papers through online sales channels, those imply that the demand of HIV self-test is in increasing year by year.In this paper, aims to understand the current situation of HIV rapid test led by CBOs and the approach, strategies and results of social marketing by means of expert interviews and site visits. Hope to illustrate the current situation, and make recommendations for future work.

  1. [Evaluation of a rapid trehalase test for the identification of Candida glabrata].

    Science.gov (United States)

    Kirdar, Sevin; Gültekin, Berna; Evcil, Gonca; Ozkütük, Aydan; Sener, Asli Gamze; Aydin, Neriman

    2009-04-01

    Candida species which cause local infections, may also lead to fatal systemic infections. The increasing incidence of non-albicans Candida, especially fluconazole susceptible or resistant dose-dependent C. glabrata, increased the importance of rapid and accurate species level identification for Candida. Rapid and correct identification of C. glabrata is essential for the initiation of the appropriate antifungal therapy. This study was conducted to evaluate the performance of the rapid trehalase test in the diagnosis of C. glabrata isolates. A total of 173 Candida strains isolated from various clinical specimens and identified according to germ tube test, growth on cornmeal Tween 80 agar and the colony morphologies on Mast-CHROMagar Candida medium (Mast Diagnostics, UK), were included to the study. The identification of non-albicans Candida species were also confirmed by API 20CAUX (BioMerieux, France) system. Accordingly 86 (50%) of the isolates were identified as C. glabrata, 48 (28%) C. albicans, 17 (10%) C. krusei, 13 (8%) C. tropicalis, 5 (3%) C. parapsilosis, 3 (2%) C. kefyr and 1 (1%) Cutilis. In order to detect the presence of trehalase enzyme in Condida strains, all isolates were grown on Sabouraud dextrose agar containing 4% glucose and then one yeast colony was emulsified in 50 microl of citrate buffer containing 4% (wt/vol) trehalose for 3 h at 37 degrees C. Presence of glucose which emerged after the action of trehalase on trehalose, was detected by a commercial "urinary glucose detection dipstick" (Spinreacta, Spain). All C. glabrata strains yielded positive result by trehalase test. None C. glabrata isolates were found negative by trehalase test except for one strain of C. tropicalis. In this study, the trehalase test allowed identification of C. globrata with 100% sensitivity and 98.9% specificity. It was concluded that trehalase test is a rapid, cost-effective and simple test that can be used for the accurate identification of C. glabrata.

  2. Biochemical Network Stochastic Simulator (BioNetS: software for stochastic modeling of biochemical networks

    Directory of Open Access Journals (Sweden)

    Elston Timothy C

    2004-03-01

    Full Text Available Abstract Background Intrinsic fluctuations due to the stochastic nature of biochemical reactions can have large effects on the response of biochemical networks. This is particularly true for pathways that involve transcriptional regulation, where generally there are two copies of each gene and the number of messenger RNA (mRNA molecules can be small. Therefore, there is a need for computational tools for developing and investigating stochastic models of biochemical networks. Results We have developed the software package Biochemical Network Stochastic Simulator (BioNetS for efficientlyand accurately simulating stochastic models of biochemical networks. BioNetS has a graphical user interface that allows models to be entered in a straightforward manner, and allows the user to specify the type of random variable (discrete or continuous for each chemical species in the network. The discrete variables are simulated using an efficient implementation of the Gillespie algorithm. For the continuous random variables, BioNetS constructs and numerically solvesthe appropriate chemical Langevin equations. The software package has been developed to scale efficiently with network size, thereby allowing large systems to be studied. BioNetS runs as a BioSpice agent and can be downloaded from http://www.biospice.org. BioNetS also can be run as a stand alone package. All the required files are accessible from http://x.amath.unc.edu/BioNetS. Conclusions We have developed BioNetS to be a reliable tool for studying the stochastic dynamics of large biochemical networks. Important features of BioNetS are its ability to handle hybrid models that consist of both continuous and discrete random variables and its ability to model cell growth and division. We have verified the accuracy and efficiency of the numerical methods by considering several test systems.

  3. evaluation of a rapid test for hiv antibodies in saliva and blood

    African Journals Online (AJOL)

    To test whole blood and saliva for HIV antibodies. (anti-HIV) using a rapid test strip capillary flow . immunoassay ... Design. A prospective pilot study of selected HIV-positive and ... defined by the underlying illness or condition is illustrated in.

  4. HIV Rapid Testing in a VA Emergency Department Setting: Cost Analysis at 5 Years.

    Science.gov (United States)

    Knapp, Herschel; Chan, Kee

    2015-07-01

    To conduct a comprehensive cost-minimization analysis to comprehend the financial attributes of the first 5 years of an implementation wherein emergency department (ED) registered nurses administered HIV oral rapid tests to patients. A health science research implementation team coordinated with ED stakeholders and staff to provide training, implementation guidelines, and support to launch ED registered nurse-administered HIV oral rapid testing. Deidentified quantitative data were gathered from the electronic medical records detailing quarterly HIV rapid test rates in the ED setting spanning the first 5 years. Comprehensive cost analyses were conducted to evaluate the financial impact of this implementation. At 5 years, a total of 2,620 tests were conducted with a quarterly mean of 131 ± 81. Despite quarterly variability in testing rates, regression analysis revealed an average increase of 3.58 tests per quarter. Over the course of this implementation, Veterans Health Administration policy transitioned from written to verbal consent for HIV testing, serving to reduce the time and cost(s) associated with the testing process. Our data indicated salient health outcome benefits for patients with respect to the potential for earlier detection, and associated long-run cost savings. Copyright © 2015. Published by Elsevier Inc.

  5. Repeat confirmatory testing for persons with discordant whole blood and oral fluid rapid HIV test results: findings from post marketing surveillance.

    Directory of Open Access Journals (Sweden)

    Laura G Wesolowski

    Full Text Available BACKGROUND: Reactive oral fluid and whole blood rapid HIV tests must be followed with a confirmatory test (Western blot (WB, immunofluorescent assay (IFA or approved nucleic acid amplification test (NAAT. When the confirmatory result is negative or indeterminate (i.e. discordant with rapid result, repeat confirmatory testing should be conducted using a follow-up specimen. Previous reports have not described whether repeat testing adequately resolves the HIV-infection status of persons with discordant results. METHODOLOGY: Post-marketing surveillance was conducted in 368 testing sites affiliated with 14 state and 2 city health departments from August 11, 2004 to June 30, 2005 and one health department through December 31, 2005. For persons with discordant results, data were collected on demographics, risk behaviors, HIV test results and specimen types. Persons with repeat confirmatory results were classified as HIV-infected or uninfected. Regression models were created to assess risk factors for not having repeat testing. PRINCIPAL FINDINGS: Of 167,371 rapid tests conducted, 2589 (1.6% were reactive: of these, 2417 (93% had positive WB/IFA, 172 (7% had negative or indeterminate WB/IFA. Of 89/172 (52% persons with a repeat confirmatory test: 17 (19% were HIV-infected, including 3 with indeterminate WB and positive NAAT; 72 (81% were uninfected, including 12 with repeat indeterminate WB. Factors associated with HIV-infection included having an initial indeterminate WB/IFA (vs. negative (p<0.001 and having an initial oral fluid WB (vs. serum (p<0.001. Persons who had male-female sex (vs. male-male sex were at increased risk for not having a repeat test [adjusted OR 2.6, 95% CI (1.3, 4.9]. CONCLUSIONS: Though only half of persons with discordant results had repeat confirmatory testing, of those who did, nearly one in five were HIV-infected. These findings underscore the need for rapid HIV testing programs to increase repeat confirmatory testing for

  6. Evaluation of a rapid test for HIV antibodies in saliva and blood ...

    African Journals Online (AJOL)

    Objective. To test whole blood and saliva for HIV antibodies (anti-HIV) using a rapid test strip capillary flow . immunoassay, and to correlate the test strip results with blood specimen results obtained from routine diagnostic antiHIV assays. Design. A prospective pilot study of selected HIV-positive and HIV-negative individuals ...

  7. 9 CFR 147.3 - The stained-antigen, rapid, whole-blood test. 3

    Science.gov (United States)

    2010-01-01

    ...-blood test. 3 147.3 Section 147.3 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE... Blood Testing Procedures § 147.3 The stained-antigen, rapid, whole-blood test. 3 3 The procedure described is a modification of the method reported by Schaffer, MacDonald, Hall, and Bunyea, Jour. Amer. Vet...

  8. Rapid diagnostic tests for typhoid and paratyphoid (enteric) fever

    Science.gov (United States)

    Wijedoru, Lalith; Mallett, Sue; Parry, Christopher M

    2017-01-01

    Background Differentiating both typhoid (Salmonella Typhi) and paratyphoid (Salmonella Paratyphi A) infection from other causes of fever in endemic areas is a diagnostic challenge. Although commercial point-of-care rapid diagnostic tests (RDTs) for enteric fever are available as alternatives to the current reference standard test of blood or bone marrow culture, or to the widely used Widal Test, their diagnostic accuracy is unclear. If accurate, they could potentially replace blood culture as the World Health Organization (WHO)-recommended main diagnostic test for enteric fever. Objectives To assess the diagnostic accuracy of commercially available rapid diagnostic tests (RDTs) and prototypes for detecting Salmonella Typhi or Paratyphi A infection in symptomatic persons living in endemic areas. Search methods We searched the Cochrane Infectious Diseases Group Specialized Register, MEDLINE, Embase, Science Citation Index, IndMED, African Index Medicus, LILACS, ClinicalTrials.gov, and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) up to 4 March 2016. We manually searched WHO reports, and papers from international conferences on Salmonella infections. We also contacted test manufacturers to identify studies. Selection criteria We included diagnostic accuracy studies of enteric fever RDTs in patients with fever or with symptoms suggestive of enteric fever living in endemic areas. We classified the reference standard used as either Grade 1 (result from a blood culture and a bone marrow culture) or Grade 2 (result from blood culture and blood polymerase chain reaction, or from blood culture alone). Data collection and analysis Two review authors independently extracted the test result data. We used a modified QUADAS-2 extraction form to assess methodological quality. We performed a meta-analysis when there were sufficient studies for the test and heterogeneity was reasonable. Main results Thirty-seven studies met the inclusion

  9. Comparative evaluation of two rapid Salmonella-IgM tests and blood culture in the diagnosis of enteric fever.

    Science.gov (United States)

    Prasad, K J; Oberoi, J K; Goel, N; Wattal, C

    2015-01-01

    Enteric fever is a major public health problem in developing countries like India. An early and accurate diagnosis is necessary for a prompt and effective treatment. We have evaluated the diagnostic accuracy of two Rapid Salmonella-IgM tests (Typhidot-IgM and Enteroscreen-IgM) as compared to blood culture in rapid and early diagnosis of enteric fever. A total of 2,699 patients' serum samples were tested by Rapid Salmonella-IgM tests and blood culture. Patients were divided into two groups. Test group - patients with enteric fever and blood culture positives for Salmonella Typhi; and three types of Controls, i.e. patients with non-enteric fever illnesses, normal healthy controls and patients positive for S. Paratyphi- A. In addition to this we have also evaluated the significance of positive Salmonella-IgM tests among blood culture-negative cases. The overall sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of the Typhidot-IgM test and Enteroscreen-IgM test considering blood culture as gold standard were 97.29% and 88.13%, 97.40% and 87.83%, 98.18% and 92.03%, 96.15% and 82.27%, respectively. Typhidot-IgM test was found to be significantly more sensitive and specific as compared to Enteroscreen-IgM. Among blood culture-negative patients, Rapid Salmonella-IgM tests detected 72.25% additional cases of enteric fever. Although the Rapid Salmonella-IgM tests are meant to diagnose S. Typhi only, but these tests detect S. Paratyphi- A also. Thirty-eight patients who were blood culture-positive for S. Paratyphi- A were also positive by Rapid Salmonella-IgM tests. Rapid Salmonella-IgM tests offer an advantage of increased sensitivity, rapidity, early diagnosis and simplicity over blood culture.

  10. Biochemical characterization of cholesterol-reducing Eubacterium.

    OpenAIRE

    Mott, G E; Brinkley, A W; Mersinger, C L

    1980-01-01

    We characterized two isolates of cholesterol-reducing Eubacterium by conducting conventional biochemical tests and by testing various sterols and glycerolipids as potential growth factors. In media containing cholesterol and plasmenylethanolamine, the tests for nitrate reduction, indole production, and gelatin and starch hydrolyses were negative, and no acid was produced from any of 22 carbohydrates. Both isolates hydrolyzed esculin to esculetin, indicating beta-glycosidase activity. In addit...

  11. Study on color difference estimation method of medicine biochemical analysis

    Science.gov (United States)

    Wang, Chunhong; Zhou, Yue; Zhao, Hongxia; Sun, Jiashi; Zhou, Fengkun

    2006-01-01

    The biochemical analysis in medicine is an important inspection and diagnosis method in hospital clinic. The biochemical analysis of urine is one important item. The Urine test paper shows corresponding color with different detection project or different illness degree. The color difference between the standard threshold and the test paper color of urine can be used to judge the illness degree, so that further analysis and diagnosis to urine is gotten. The color is a three-dimensional physical variable concerning psychology, while reflectance is one-dimensional variable; therefore, the estimation method of color difference in urine test can have better precision and facility than the conventional test method with one-dimensional reflectance, it can make an accurate diagnose. The digital camera is easy to take an image of urine test paper and is used to carry out the urine biochemical analysis conveniently. On the experiment, the color image of urine test paper is taken by popular color digital camera and saved in the computer which installs a simple color space conversion (RGB -> XYZ -> L *a *b *)and the calculation software. Test sample is graded according to intelligent detection of quantitative color. The images taken every time were saved in computer, and the whole illness process will be monitored. This method can also use in other medicine biochemical analyses that have relation with color. Experiment result shows that this test method is quick and accurate; it can be used in hospital, calibrating organization and family, so its application prospect is extensive.

  12. Genetic, histochemical and biochemical studies on goat TSE cases from Cyprus.

    Science.gov (United States)

    Niedermeyer, Susanne; Eiden, Martin; Toumazos, Pavlos; Papasavva-Stylianou, Penelope; Ioannou, Ioannis; Sklaviadis, Theodoros; Panagiotidis, Cynthia; Langeveld, Jan; Bossers, Alex; Kuczius, Thorsten; Kaatz, Martin; Groschup, Martin H; Fast, Christine

    2016-10-06

    Scrapie and bovine spongiform encephalopathy (BSE) are transmissible spongiform encephalopathies (TSE's) affecting sheep and goats. Susceptibility of goats to scrapie is influenced by polymorphisms of the prion protein gene (PRNP) of the host. Five polymorphisms are associated with reduced susceptibility to TSE's. In the study presented here caprine samples from a scrapie eradication program on Cyprus were genotyped and further characterized using BioRad TeSeE rapid test, histological, immunohistochemical and biochemical methods. In total 42 goats from 20 flocks were necropsied from which 25 goats showed a positive result in the rapid test, a spongiform encephalopathy and an accumulation of pathological prion protein (PrP Sc ) in the obex. PrP Sc deposits were demonstrated in the placenta, peripheral nervous and lymphoreticular system. Two animals showed PrP Sc -accumulations in peripheral tissues only. By discriminatory immunoblots a scrapie infection could be confirmed for all cases. Nevertheless, slight deviations in the glycosylation pattern might indicate the presence of different scrapie strains. Furthermore scrapie samples from goats in the current study demonstrated less long term resistance to proteinase K than ovine or caprine BSE control samples. Reduced scrapie susceptibility according to the PRNP genotype was demonstrated (Fishers Exact test, p goats with at least one polymorphism (p = 0.023) at the six codons examined and in particular for those with polymorphisms at codon 146 (p = 0.016). This work characterizes scrapie in goats having implications for breeding and surveillance strategies.

  13. Addressing unmet need for HIV testing in emergency care settings: a role for computer-facilitated rapid HIV testing?

    Science.gov (United States)

    Kurth, Ann E; Severynen, Anneleen; Spielberg, Freya

    2013-08-01

    HIV testing in emergency departments (EDs) remains underutilized. The authors evaluated a computer tool to facilitate rapid HIV testing in an urban ED. Randomly assigned nonacute adult ED patients were randomly assigned to a computer tool (CARE) and rapid HIV testing before a standard visit (n = 258) or to a standard visit (n = 259) with chart access. The authors assessed intervention acceptability and compared noted HIV risks. Participants were 56% nonWhite and 58% male; median age was 37 years. In the CARE arm, nearly all (251/258) of the patients completed the session and received HIV results; four declined to consent to the test. HIV risks were reported by 54% of users; one participant was confirmed HIV-positive, and two were confirmed false-positive (seroprevalence 0.4%, 95% CI [0.01, 2.2]). Half (55%) of the patients preferred computerized rather than face-to-face counseling for future HIV testing. In the standard arm, one HIV test and two referrals for testing occurred. Computer-facilitated HIV testing appears acceptable to ED patients. Future research should assess cost-effectiveness compared with staff-delivered approaches.

  14. Two rapid pigmentation tests for identification of Cryptococcus neoformans.

    Science.gov (United States)

    Kaufmann, C S; Merz, W G

    1982-01-01

    Two tests were developed for the rapid identification of Cryptococcus neoformans based on pigment produced by the organism's phenoloxidase activity. Caffeic acid was incorporated into cornmeal agar, a medium used routinely for yeast identification. When tested on this medium, only C. neoformans isolates produced brown pigment. All other yeasts maintained their normal morphology and did not produce the reaction product. A non-medium-based test was developed for same-day identification of C. neoformans isolates. Paper strips saturated with a buffered L-beta-3,4-dihydroxyphenylalanine-ferric citrate solution were inoculated with isolates and incubated at 37 degrees C. Pigment production occurred only with C. neoformans isolates, many within 60 to 90 min. All other yeasts remained negative. PMID:7040452

  15. Evaluation of a rapid immunodiagnostic test kit for detection of African lyssaviruses from brain material

    Directory of Open Access Journals (Sweden)

    W. Markotter

    2009-09-01

    Full Text Available Rapid immunodiagnostic test kit was evaluated against a selection of isolates of lyssavirus genotypes occurring in Africa. The test was carried out in parallel comparison with the fluorescent antibody test (FAT and isolates representing previously established phylogenetic groups from each genotype were included. The specificity of the rapid immunodiagnostic test compared favourably with the FAT and was found to detect all representatives of genotypes 1, 2, 3 and 4 in brain samples of either field cases or suckling mouse brain inoculates.

  16. Biochemical evaluation of phenylketonuria (PKU: from diagnosis to treatment

    Directory of Open Access Journals (Sweden)

    Leticia Belmont-Martínez

    2014-07-01

    Besides periodical Phe and Tyr testing, biochemical follow-up includes the measurement of necessary elements that guarantee normal physical and intellectual development such as selenium, zinc, B12 vitamin, folates, iron and long chain fatty acids. Clinical context is as important as biochemical status so periodic evaluation of nutritional, medical, social and psychological aspects should be included.

  17. DETECTION OF RABIES VIRAL ANTIGEN IN CATTLE BY RAPID IMMUNOCHROMTOGRAPHIC DIAGNOSTIC TEST

    Directory of Open Access Journals (Sweden)

    Santanu Panda

    2016-06-01

    Full Text Available In recent years, improved quality, accuracy and speed for diagnosis of rabies has been adopted for rabies control strategies in developing countries. In field condition, rapid immunochromtographic diagnostic test (RIDT is a true requirement for rapid epidemiological surveillance of rabies. In the present study, a total of ten numbers of rabies suspected cattle brain sample form different parts of West Bengal, India were examined through RIDT. The results revealed that one sample was found to be positive. The test was established as powerful screening tool for rabies with high sensitivity and specificity. Thus, RIDT can be employed as a reliable and quick approach for diagnosis and control of rabies under field condition.

  18. Development of a new first-aid biochemical detector

    Science.gov (United States)

    Hu, Jingfei; Liao, Haiyang; Su, Shilin; Ding, Hao; Liu, Suquan

    2016-10-01

    The traditional biochemical detector exhibits poor adaptability, inconvenient carrying and slow detection, which can't meet the needs of first-aid under field condition like natural or man-made disasters etc. Therefore a scheme of first-aid biochemical detector based on MOMES Micro Spectrometer, UV LED and Photodiode was proposed. An optical detection structure combined continuous spectrum sweep with fixed wavelength measurement was designed, which adopted mobile detection optical path consisting of Micro Spectrometer and Halogen Lamp to detect Chloride (Cl-), Creatinine (Cre), Glucose (Glu), Hemoglobin (Hb). The UV LED and Photodiode were designed to detect Potassium (K-), Carbon dioxide (CO2), Sodium (Na+). According to the field diagnosis and treatment requirements, we designed the embedded control hardware circuit and software system, the prototype of first-aid biochemical detector was developed and the clinical trials were conducted. Experimental results show that the sample's absorbance repeatability is less than 2%, the max coefficient of variation (CV) in the batch repeatability test of all 7 biochemical parameters in blood samples is 4.68%, less than the clinical requirements 10%, the correlation coefficient (R2) in the clinical contrast test with AU5800 is almost greater than 0.97. To sum up, the prototype meets the requirements of clinical application.

  19. Factors associated with willingness to accept oral fluid HIV rapid testing among most-at-risk populations in China.

    Directory of Open Access Journals (Sweden)

    Huanmiao Xun

    Full Text Available The availability of oral fluid HIV rapid testing provides an approach that may have the potential to expand HIV testing in China, especially among most-a-risk populations. There are few investigations about the acceptability of oral fluid HIV testing among most-at-risk populations in China.A cross-sectional study with men who have sex with men (MSM, female sex workers (FSW and voluntary counseling and testing (VCT clients was conducted in three cities of Shandong province, China from 2011 to 2012. Data were collected by face-to-face questionnaire.About 71% of participants were willing to accept the oral fluid HIV rapid testing, and home HIV testing was independently associated with acceptability of the new testing method among MSM, FSW and VCT clients (AOR of 4.46, 3.19 and 5.74, respectively. Independent predictors of oral fluid HIV rapid testing acceptability among MSM were having ever taken an oral fluid HIV rapid test (AOR= 15.25, having ever taken an HIV test (AOR= 2.07, and education level (AOR= 1.74. Engagement in HIV-related risk behaviors (AOR= 1.68 was an independent predictor of acceptability for FSW. Having taken an HIV test (AOR= 2.85 was an independent predictor of acceptability for VCT clients. The primary concern about the oral fluid HIV testing was accuracy. The median price they would pay for the testing ranged from 4.8 to 8.1 U.S. dollars.High acceptability of oral fluid HIV rapid testing was shown among most-at-risk populations. Findings provide support for oral rapid HIV testing as another HIV prevention tool, and provide a backdrop for the implementation of HIV home testing in the near future. Appropriate pricing and increased public education through awareness campaigns that address concerns about the accuracy and safety of the oral fluid HIV rapid testing may help increase acceptability and use among most-at-risk populations in China.

  20. Laboratory and On-Site Tests for Rapid Runway Repair

    Directory of Open Access Journals (Sweden)

    Federico Leonelli

    2017-11-01

    Full Text Available The attention to rapid pavement repair has grown fast in recent decades: this topic is strategic for the airport management process for civil purposes and peacekeeping missions. This work presents the results of laboratory and on-site tests for rapid runway repair, in order to analyse and compare technical and mechanical performances of 12 different materials currently used in airport. The study focuses on site repairs, a technique adopted most frequently than repairs with modular elements. After describing mechanical and physical properties of the examined materials (2 bituminous emulsions, 5 cement mortars, 4 cold bituminous mixtures and 1 expanding resin, the study presents the results of carried out mechanical tests. The results demonstrate that the best performing material is a one-component fast setting and hardening cement mortar with graded aggregates. This material allows the runway reopening 6 h after the work. A cold bituminous mixture (bicomponent premixed cold asphalt with water as catalyst and the ordinary cement concrete allow the reopening to traffic after 18 h, but both ensure a lower service life (1000 coverages than the cement mortar (10,000 coverages. The obtained results include important information both laboratory level and field, and they could be used by airport management bodies and road agencies when scheduling and evaluating pavement repairs.

  1. Performance of a rapid self-test for detection of Trichomonas vaginalis in South Africa and Brazil

    NARCIS (Netherlands)

    Jones, Heidi E.; Lippman, Sheri A.; Caiaffa-Filho, Helio H.; Young, Taryn; van de Wijgert, Janneke H. H. M.

    2013-01-01

    Women participating in studies in Brazil (n = 695) and South Africa (n = 230) performed rapid point-of-care tests for Trichomonas vaginalis on self-collected vaginal swabs. Using PCR as the gold standard, rapid self-testing achieved high specificity (99.1%; 95% confidence interval [CI], 98.2 to

  2. Comparative effectiveness of single and dual rapid diagnostic tests for syphilis and HIV in antenatal care services in Colombia.

    Science.gov (United States)

    Gaitán-Duarte, Hernando Guillermo; Newman, Lori; Laverty, Maura; Habib, Ndema Abu; González-Gordon, Lina María; Ángel-Müller, Edith; Abella, Catleya; Barros, Esther Cristina; Rincón, Carlos; Caicedo, Sidia; Gómez, Bertha; Pérez, Freddy

    2016-12-01

    To assess the effectiveness of a dual rapid test compared to a single rapid test for syphilis and HIV screening. A cluster-randomized open-label clinical trial was performed in 12 public antenatal care (ANC) centers in the cities of Bogotá and Cali, Colombia. Pregnant women who were over 14 years of age at their first antenatal visit and who had not been previously tested for HIV and syphilis during the current pregnancy were included. Pregnant women were randomized to single HIV and single syphilis rapid diagnostic tests (Arm A) or to dual HIV and syphilis rapid diagnostic tests (Arm B). The four main outcomes measured were: (1) acceptability of the test, (2) uptake in testing, (3) treatment on the same day (that is, timely treatment), and (4) treatment at any time for positive rapid test cases. Bivariate and multivariate analyses were calculated to adjust for the clustering effect and the period. A total of 1 048 patients were analyzed in Arm A, and 1 166 in Arm B. Acceptability of the rapid tests was 99.8% in Arm A and 99.6% in Arm B. The prevalence of positive rapid tests was 2.21% for syphilis and 0.36% for HIV. Timely treatment was provided to 20 of 29 patients (69%) in Arm A and 16 of 20 patients (80%) in Arm B (relative risk (RR), 1.10; 95% confidence interval (CI): (1.00 -1.20). Treatment at any time was given to 24 of 29 patients (83%) in Arm A and to 20 of 20 (100%) in Arm B (RR, 1.11; 95% CI: 1.01-1.22). There were no differences in patient acceptability, testing and timely treatment between dual rapid tests and single rapid tests for HIV and syphilis screening in the ANC centers. Same-day treatment depends also on the interpretation of and confidence in the results by the health providers.

  3. Comparative effectiveness of single and dual rapid diagnostic tests for syphilis and HIV in antenatal care services in Colombia

    Directory of Open Access Journals (Sweden)

    Hernando Guillermo Gaitán-Duarte

    Full Text Available ABSTRACT Objective To assess the effectiveness of a dual rapid test compared to a single rapid test for syphilis and HIV screening. Methods A cluster-randomized open-label clinical trial was performed in 12 public antenatal care (ANC centers in the cities of Bogotá and Cali, Colombia. Pregnant women who were over 14 years of age at their first antenatal visit and who had not been previously tested for HIV and syphilis during the current pregnancy were included. Pregnant women were randomized to single HIV and single syphilis rapid diagnostic tests (Arm A or to dual HIV and syphilis rapid diagnostic tests (Arm B. The four main outcomes measured were: (1 acceptability of the test, (2 uptake in testing, (3 treatment on the same day (that is, timely treatment, and (4 treatment at any time for positive rapid test cases. Bivariate and multivariate analyses were calculated to adjust for the clustering effect and the period. Results A total of 1 048 patients were analyzed in Arm A, and 1 166 in Arm B. Acceptability of the rapid tests was 99.8% in Arm A and 99.6% in Arm B. The prevalence of positive rapid tests was 2.21% for syphilis and 0.36% for HIV. Timely treatment was provided to 20 of 29 patients (69% in Arm A and 16 of 20 patients (80% in Arm B (relative risk (RR, 1.10; 95% confidence interval (CI: (1.00 −1.20. Treatment at any time was given to 24 of 29 patients (83% in Arm A and to 20 of 20 (100% in Arm B (RR, 1.11; 95% CI: 1.01−1.22. Conclusions There were no differences in patient acceptability, testing and timely treatment between dual rapid tests and single rapid tests for HIV and syphilis screening in the ANC centers. Same-day treatment depends also on the interpretation of and confidence in the results by the health providers.

  4. Post-marketing surveillance of OraQuick whole blood and oral fluid rapid HIV testing.

    Science.gov (United States)

    Wesolowski, Laura G; MacKellar, Duncan A; Facente, Shelley N; Dowling, Teri; Ethridge, Steven F; Zhu, Julia H; Sullivan, Patrick S

    2006-08-01

    Post-marketing surveillance was conducted to monitor the performance of the OraQuick Advance rapid HIV-1/2 antibody test (OraQuick) on whole blood and oral fluid. Surveillance of routinely collected data on clients tested with OraQuick in 368 testing sites affiliated with 17 state and city health departments between 11 August 2004 and 30 June 2005. For whole blood and oral fluid, we report the median (range) health department OraQuick specificity and positive predictive value (PPV), and the number of clients with discordant results (e.g. who had a reactive rapid test not confirmed positive by Western blot or indirect immunofluorescence). At one site with lower than expected oral-fluid specificity, we evaluated whether device expiration, manufacturing lot, operator practices, or device-storage or testing-area temperatures were associated with false-positive tests. During the surveillance period, 135 724 whole blood and 26 066 oral fluid rapid tests were conducted. The median health department whole blood OraQuick specificity was 99.98% (range: 99.73-100%) and PPV was 99.24% (range: 66.67-100%); the median oral fluid specificity was 99.89% (range: 99.44-100%) and PPV was 90.00% (range: 50.00-100%). A total of 124 discordant results were reported from 68 (0.05%) whole blood and 56 (0.22%) oral fluid rapid tests. The oral fluid specificity at the site with excess oral fluid false-positive tests was 98.7% (95% confidence interval: 98.18-99.11%). The increase in false-positive tests at that site was not associated with any specific device characteristic, operator procedure or temperature condition. The specificity of OraQuick performed on whole blood and oral fluid during post-marketing surveillance was compatible with the manufacturer's claim within the package insert. However, one site experienced lower than expected oral fluid specificity. Sites that observe that the specificity of OraQuick is lower than the range indicated in the package insert should notify the

  5. Evaluation of dengue NS1 antigen rapid tests and ELISA kits using clinical samples.

    Directory of Open Access Journals (Sweden)

    Subhamoy Pal

    Full Text Available Early diagnosis of dengue virus (DENV infection can improve clinical outcomes by ensuring close follow-up, initiating appropriate supportive therapies and raising awareness to the potential of hemorrhage or shock. Non-structural glycoprotein-1 (NS1 has proven to be a useful biomarker for early diagnosis of dengue. A number of rapid diagnostic tests (RDTs and enzyme-linked immunosorbent assays (ELISAs targeting NS1 antigen (Ag are now commercially available. Here we evaluated these tests using a well-characterized panel of clinical samples to determine their effectiveness for early diagnosis.Retrospective samples from South America were used to evaluate the following tests: (i "Dengue NS1 Ag STRIP" and (ii "Platelia Dengue NS1 Ag ELISA" (Bio-Rad, France, (iii "Dengue NS1 Detect Rapid Test (1st Generation" and (iv "DENV Detect NS1 ELISA" (InBios International, United States, (v "Panbio Dengue Early Rapid (1st generation" (vi "Panbio Dengue Early ELISA (2nd generation" and (vii "SD Bioline Dengue NS1 Ag Rapid Test" (Alere, United States. Overall, the sensitivity of the RDTs ranged from 71.9%-79.1% while the sensitivity of the ELISAs varied between 85.6-95.9%, using virus isolation as the reference method. Most tests had lower sensitivity for DENV-4 relative to the other three serotypes, were less sensitive in detecting secondary infections, and appeared to be most sensitive on Day 3-4 post symptom onset. The specificity of all evaluated tests ranged from 95%-100%.ELISAs had greater overall sensitivity than RDTs. In conjunction with other parameters, the performance data can help determine which dengue diagnostics should be used during the first few days of illness, when the patients are most likely to present to a clinic seeking care.

  6. Assessing the variability of outcome for patients treated with localized prostate irradiation using different definitions of biochemical control

    International Nuclear Information System (INIS)

    Horwitz, Eric; Ziaja, Ellen; Vicini, Frank; Dmuchowski, Carl; Gonzalez, Jose; Stromberg, Jannifer; Brabbins, Donald; Hollander, Jay; Chen, Peter; Martinez, Alvaro

    1995-01-01

    Purpose: Biochemical control is rapidly becoming the standard to assess treatment outcome of clinically localized prostate cancer. However, no standardized definition of biochemical control has been established. We reviewed our experience treating patients with localized prostate cancer and applied 3 different commonly used definitions to estimate the variability in rates of biochemical control. Materials and Methods: Between (1(87)) and (12(91)), 480 patients with clinically localized prostate cancer received uniform treatment with external beam irradiation (RT) using localized prostate fields at William Beaumont Hospital. The median dose to the prostate was 66.6 Gy (range 58 to 70.4 Gy) through a 4 field technique. A total of 14 patients received pelvic nodal RT (median dose 45 Gy). Four hundred seventy patients had post-treatment (posttx) PSA values and 414 patients had pre-treatment (pretx) PSA values. Three different definitions of biochemical control were used: 1) Biochemical control was defined as posttx PSA nadir < 1 ng/ml within 1 year. After achieving nadir, if there were 2 consecutive increases, the patient was scored a failure at the time of the first increase; 2) Biochemical control was defined as posttx PSA nadir < 1.5 ng/ml within 1 year. After achieving nadir, if there were 2 consecutive increases, the patient was scored a failure at the time of the first increase; 3) Posttx PSA nadir < 4 ng/ml without a time limit. Once the nadir was achieved, and it did not rise above normal, the patient was considered controlled. Clinical local control was defined as no palpable prostate nodularity beyond 18 months, no new prostate nodularity, or a negative biopsy. If hormonal therapy was started, the patient was censored for biochemical failure at that time. Results: Median follow-up is 48 months (range 3 to 112 months). Pre-treatment PSA values were correlated with biochemical response using the 3 definitions of biochemical control as well as clinical local

  7. Rapid estimation of the biochemical methane potential of plant biomasses using Fourier transform mid-infrared photoacoustic spectroscopy.

    Science.gov (United States)

    Bekiaris, Georgios; Triolo, Jin M; Peltre, Clément; Pedersen, Lene; Jensen, Lars S; Bruun, Sander

    2015-12-01

    Biochemical methane potential (BMP) is a very important characteristic of a given feedstock for optimisation of its use in biogas production. However, the long digestion time needed to determine BMP is the main limitation for the use of this assay during the operation of anaerobic digesters to produce biogas. Fourier transform mid-infrared photoacoustic spectroscopy (FTIR-PAS) was used to predict the BMP of 87 plant biomasses. The developed calibration model was able to explain 81% of the variance in the measured BMP of a selected test set with a root mean square error (RMSE) of 40NLCH4kg(-1) of volatile solids (VS) and a ratio of performance to deviation (RPD) of 2.38. The interpretation of the regression coefficients used in the calibration revealed a positive correlation of BMP with easily degradable compounds (amorphous cellulose, hemicellulose and aliphatic compounds) and a negative correlation with inhibitors of cellulose hydrolysis (lignin, hemicellulose). Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. [Attempt for development of rapid word reading test for children--evaluation of reliability and validity].

    Science.gov (United States)

    Hashimoto, Ryusaku; Kashiwagi, Mitsuru; Suzuki, Shuhei

    2008-09-01

    We developed a rapid word reading test for examining the phonological processing ability of Japanese children. We prepared two versions of the test, version A and B. Each test has word and non-word tasks. Twenty-two healthy boys of third grade in primary schools participated in this validation study. For criterion related validity, we performed the serial Hiragana reading test, the sentence reading test, Raven's coloured progressive matrices (RCPM), the Token test for children, the Kana word dictation test, the standardized comprehension test of abstract words (SCTAW), and Trail Circle test. The reading times of the newly developed test correlated moderately or highly with those of the serial Hiragana reading test and the sentence reading test. However, the scores of the other tests (RCPM, Token test for children, Kana word dictation test, SCTAW, Trail Circle test) did not correlated with the reading time of the rapid word reading test. Test-retest reliabilities in the word tasks were more than moderate: 0.52 and 0.76 in versions A and B, while those in the non-word tasks were high: 0.91 and 0.88 in versions A and B. The correlation coefficient between versions A and B was 0.7 for the word tasks and 0.92 for the non-word tasks. This study showed that the rapid word reading test has substantial validity and reliability for testing the phonological processing ability of Japanese children. In addition, the non-word tasks were more suitable for selectively examining the speed of the grapheme to phoneme conversion process.

  9. Rapid antibiotic susceptibility testing of Mycobacterium tuberculosis : Its utility in resource poor settings

    Directory of Open Access Journals (Sweden)

    Poojary A

    2006-01-01

    Full Text Available Purpose: To compare the rapid colorimetric nitrate reductase based antibiotic susceptibility (CONRAS test performed on Mycobacterium tuberculosis isolates with the conventional method i.e., the proportion method. Methods: One hundred clinical isolates of M. tuberculosis were tested for susceptibility to isoniazid (INH and rifampicin (RIF by the conventional proportion method and CONRAS in Middlebrook 7H9 liquid medium enriched with growth supplements (MB7H9S. Results: The performance of the CONRAS test was evaluated using proportion method as the gold standard. The sensitivity (ability to detect true drug resistance and specificity (ability to detect true drug susceptibility of the CONRAS test to INH was 93.75 and 98.52% and for RIF it was 96.10 and 100% respectively. The mean time for reporting was 6.3 days and the test showed excellent reproducibility. The kappa (k value for INH was 0.92 and for RIF was 0.99, indicating excellent agreement between the two methods. Conclusions: CONRAS test is a rapid and reliable method of drug susceptibility for M. tuberculosis.

  10. Rapid testing may not improve uptake of HIV testing and same day results in a rural South African community: a cohort study of 12,000 women.

    Directory of Open Access Journals (Sweden)

    Ntombizodumo B Mkwanazi

    Full Text Available Rapid testing of pregnant women aims to increase uptake of HIV testing and results and thus optimize care. We report on the acceptability of HIV counselling and testing, and uptake of results, before and after the introduction of rapid testing in this area.HIV counsellors offered counselling and testing to women attending 8 antenatal clinics, prior to enrolment into a study examining infant feeding and postnatal HIV transmission. From August 2001 to April 2003, blood was sent for HIV ELISA testing in line with the Prevention of Mother-to-Child Transmission (PMTCT programme in the district. From May 2003 to September 2004 women were offered a rapid HIV test as part of the PMTCT programme, but also continued to have ELISA testing for study purposes. Of 12,323 women counselled, 5,879 attended clinic prior to May 2003, and 6,444 after May 2003 when rapid testing was introduced; of whom 4,324 (74.6% and 4,810 (74.6% agreed to have an HIV test respectively. Of the 4,810 women who had a rapid HIV test, only 166 (3.4% requested to receive their results on the same day as testing, the remainder opted to return for results at a later appointment. Women with secondary school education were less likely to agree to testing than those with no education (AOR 0.648, p35 years (AOR 0.756, p<0.01 compared to those <20 years.Contrary to other reports, few women who had rapid tests accepted their HIV results the same day. Finding strategies to increase the proportion of pregnant women knowing their HIV results is critical so that appropriate care can be given.

  11. Evaluation of nine HIV rapid test kits to develop a national HIV testing algorithm in Nigeria

    Directory of Open Access Journals (Sweden)

    Orji Bassey

    2015-05-01

    Full Text Available Background: Non-cold chain-dependent HIV rapid testing has been adopted in many resource-constrained nations as a strategy for reaching out to populations. HIV rapid test kits (RTKs have the advantage of ease of use, low operational cost and short turnaround times. Before 2005, different RTKs had been used in Nigeria without formal evaluation. Between 2005 and 2007, a study was conducted to formally evaluate a number of RTKs and construct HIV testing algorithms. Objectives: The objectives of this study were to assess and select HIV RTKs and develop national testing algorithms. Method: Nine RTKs were evaluated using 528 well-characterised plasma samples. These comprised 198 HIV-positive specimens (37.5% and 330 HIV-negative specimens (62.5%, collected nationally. Sensitivity and specificity were calculated with 95% confidence intervals for all nine RTKs singly and for serial and parallel combinations of six RTKs; and relative costs were estimated. Results: Six of the nine RTKs met the selection criteria, including minimum sensitivity and specificity (both ≥ 99.0% requirements. There were no significant differences in sensitivities or specificities of RTKs in the serial and parallel algorithms, but the cost of RTKs in parallel algorithms was twice that in serial algorithms. Consequently, three serial algorithms, comprising four test kits (BundiTM, DetermineTM, Stat-Pak® and Uni-GoldTM with 100.0% sensitivity and 99.1% – 100.0% specificity, were recommended and adopted as national interim testing algorithms in 2007. Conclusion: This evaluation provides the first evidence for reliable combinations of RTKs for HIV testing in Nigeria. However, these RTKs need further evaluation in the field (Phase II to re-validate their performance.

  12. Evaluation of Blood-Based Antibody Rapid Testing for HIV Early Therapy: A Meta-Analysis of the Evidence

    Directory of Open Access Journals (Sweden)

    Xiaojie Huang

    2018-06-01

    Full Text Available BackgroundWestern blot (WB assay is considered the gold standard test for HIV infection confirmation. However, it requires technical expertise and is quite time-consuming. WHO recommends blood-based rapid diagnosis to achieve same-day test and treatment. However, this rapid testing strategy has not been promoted worldwide due to inadequate research evaluating the effectiveness of rapid tests (RTs as an alternative confirmatory HIV test for WB. This study aims to compare the diagnostic performance of rapid HIV tests compared with WB.MethodsPubMed and Web of Science were searched for publications on rapid HIV tests using blood specimen. A meta-analysis was performed to quantitatively evaluate the diagnostic performance of rapid HIV tests compared with the WB assay in terms of pooled sensitivity, specificity, area under summary receiver operating characteristic (SROC curve, and diagnostic odds ratio (DOR.ResultsTwenty articles involving 27,343 fresh specimens for rapid HIV tests were included in the meta-analysis. Regarding Capillus HIV-1/HIV-2, the pooled sensitivity, specificity, area under SROC curve, and DOR derived from six studies were 0.999 (95% CI, 0.956–1.000, 0.999 (95% CI, 0.991–1.00, 1.00 (95% CI, 0.99–1.00, and 1.0 × 106 (95% CI, 2.6 × 104–3.9 × 107 compared with the WB assay, respectively. With respect to Determine HIV-1/2, the pooled sensitivity, specificity area under SROC, and DOR derived from eight studies were 1.00 (95% CI, 0.789–1.000, 0.992 (95% CI, 0.985–0.996, 1.00 (95% CI, 0.99–1.00, and 1.8 × 106 (95% CI 406.049–7.8 × 109 compared with the WB assay, respectively. Regarding two-step serial RTs, the pooled sensitivity, specificity area under SROC, and DOR derived from eight studies were 0.998 (95% CI, 0.991–1.000, 0.998 (95% CI, 0.994–0.999, and 1.00 (95% CI 0.99–1.00 compared with the WB assay, respectively.ConclusionOur meta-analysis results may provide evidenced-based support

  13. [Introduction of rapid syphilis and HIV testing in prenatal care in Colombia: qualitative analysis].

    Science.gov (United States)

    Ochoa-Manjarrés, María Teresa; Gaitán-Duarte, Hernando Guillermo; Caicedo, Sidia; Gómez, Berta; Pérez, Freddy

    2016-12-01

    Interpret perceptions of Colombian health professionals concerning factors that obstruct and facilitate the introduction of rapid syphilis and HIV testing in prenatal care services. A qualitative study based on semi-structured interviews was carried out. A convenience sample was selected with 37 participants, who included health professionals involved in prenatal care services, programs for pregnant women, clinical laboratories, and directors of health care units or centers, as well as representatives from regional departments and the Ministry of Health. Colombia does not do widespread screening with rapid syphilis and HIV tests in prenatal care. The professionals interviewed stated they did not have prior experience in the use of rapid tests-except for laboratory staff-or in the course of action in response to a positive result. The insurance system hinders access to timely diagnosis and treatment. Health authorities perceive a need to review existing standards, strengthen the first level of care, and promote comprehensive prenatal care starting with contracts between insurers and health service institutional providers. Participants recommended staff training and integration between health-policymaking and academic entities for updating training programs. The market approach and the characteristics of the Colombian health system constitute the main barriers to implementation of rapid testing as a strategy for elimination of mother-to-child transmission of syphilis and HIV. Measures identified include making changes in contracts between insurers and health service institutional providers, adapting the timing and duration of prenatal care procedures, and training physicians and nurses involved in prenatal care.

  14. Alternative supplementary biochemic food for growing up the fresh water lobster (Cherax quadricarinatus

    Directory of Open Access Journals (Sweden)

    PRABANG SETYONO

    2009-11-01

    Full Text Available Priyono E, Astirin OP, Setyono P. 2009. Alternative supplementary biochemic food for growing up the fresh water lobster (Cherax quadricarinatus. Nusantara Bioscience 1: 123-130. This research denotes to know the influence of biochemic composition to the rapid grow of fresh water lobster on the stadium of post larva (PL of 60 within three months. This research used the complete random planning dealing with 4 treatments and each treatment would get 3 times cycle. The treatments cover, group K tested animal was treted with 100% mill food containing 30% of protein. Group A is given with food and biochemic food containing 13,34% of protein. Group B is the treated with mill food which is mixed with biochemic food containing 10,7% of protein. While group C was tested by treating them with mill food and biochemic food containing 13,58%. After all the above mentioned would be set up within 3:1 comparation. The variable of this research were the length of the abdomen, cephalothorax, total length, and the wet weight. The data analysis is using ANOVA system on 95% power test completed by of SPSS version 13. The result of the research shows that mentioned treatments give us the same influence toward the growth of fresh water lobster. The composition of biochemic food with the containing protein around 10,7%,13.34% and 13,38% has given the same effect to the lobster growth on post larva 60 level. There is strong correlation between abdomen and cephalothorax and between the total length and the lobsters weight.Key words: Cherax quadricarinatus, suplementary food, water quality.Abstrak. Priyono E, Astirin OP, Setyono P. 2009. Alternatif penambahan suplemen hayati untuk meningkatkan pertumbuhan udang lobster air tawar (Cherax quadricarinatus. Nusantara Bioscience 1: 123-130. Penelitian ini bertujuan untuk mengetahui pengaruh pemberian suplemen hayati sehingga dapat meningkatkan pertumbuhan lobster air tawar pada stadia post larva (PL 60 pada masa pertumbuhan 3

  15. An investigation on clinical, radiological and biochemical methods for assessing periodontitis activity

    International Nuclear Information System (INIS)

    Janssen, P.T.M.

    1987-01-01

    In order to recognize in which stage rapidly progressing destruction of periodontal ligament fibers occurs, a number of diagnostic methods are studied in this thesis. It turns out that the actual much utilized clinical methods can not be improved while radiological and biochemical diagnositic methods are much more promising. 106 refs.; 20 figs.; 36 tabs

  16. Miniaturized Antimicrobial Susceptibility Test by Combining Concentration Gradient Generation and Rapid Cell Culturing

    Directory of Open Access Journals (Sweden)

    Samuel C. Kim

    2015-10-01

    Full Text Available Effective treatment of bacterial infection relies on timely diagnosis and proper prescription of antibiotic drugs. The antimicrobial susceptibility test (AST is one of the most crucial experimental procedures, providing the baseline information for choosing effective antibiotic agents and their dosages. Conventional methods, however, require long incubation times or significant instrumentation costs to obtain test results. We propose a lab-on-a-chip approach to perform AST in a simple, economic, and rapid manner. Our assay platform miniaturizes the standard broth microdilution method on a microfluidic device (20 × 20 mm that generates an antibiotic concentration gradient and delivers antibiotic-containing culture media to eight 30-nL chambers for cell culture. When tested with 20 μL samples of a model bacterial strain (E. coli ATCC 25922 treated with ampicillin or streptomycin, our method allows for the determination of minimum inhibitory concentrations consistent with the microdilution test in three hours, which is almost a factor of ten more rapid than the standard method.

  17. Evaluation of SD BIOLINE H. pylori Ag rapid test against double ELISA with SD H. pylori Ag ELISA and EZ-STEP H. pylori Ag ELISA tests.

    Science.gov (United States)

    Negash, Markos; Kassu, Afework; Amare, Bemnet; Yismaw, Gizachew; Moges, Beyene

    2018-01-01

    Helicobacter pylori antibody titters fall very slowly even after successful treatment. Therefore, tests detecting H. pylori antibody lack specificity and sensitivity. On the other hand, H. pylori stool antigen tests are reported as an alternative assay because of their reliability and simplicity. However, the comparative performance of H. pylori stool antigen tests for detecting the presence of the bacterium in clinical specimens in the study area is not assessed. Therefore, in this study we evaluated the performance of SD BIOLINE H. pylori Ag rapid test with reference to the commercially available EZ- STEP ELISA and SD BIOLINE H. pylori Ag ELISA tests. Stool samples were collected to analyse the diagnostic performance of SD BIOLINE H. pylori Ag rapid test kit using SD H. pylori Ag ELISA kit and EZ- STEP ELISA tests as a gold standard. Serum samples were also collected from each patient to test for the presence of H. pylori antibodies using dBest H. pylori Test Disk. Sensitivity, specificity, predictive values and kappa value are assessed. P values H. pylori Ag rapid test were: 95.6% (95% CI, 88.8-98.8), 92.5% (95%CI, 89-94.1%), 86.7% (95% CI, 80.5-89.6), and 97.6% (95% CI, 993.9-99.3) respectively. The performance of SD BIOLINE H. pylori Ag rapid test was better than the currently available antibody test in study area. Therefore, the SD BIOLINE Ag rapid stool test could replace and be used to diagnose active H. pylori infection before the commencement of therapy among dyspeptic patients.

  18. Introducing rapid tests for malaria into the retail sector

    DEFF Research Database (Denmark)

    Hutchinson, Eleanor; Hutchison, Coll; Lal, Sham

    2017-01-01

    The observation that many people in Africa seek care for febrile illness in the retail sector has led to a number of public health initiatives to try to improve the quality of care provided in these settings. The potential to support the introduction of rapid diagnostic tests for malaria (m......RDTs) into drug shops is coming under increased scrutiny. Those in favour argue that it enables the harmonisation of policy around testing and treatment for malaria and maintains a focus on market-based solutions to healthcare. Despite the enthusiasm among many global health actors for this policy option...... in drug shops during a trial in Mukono District, Uganda. This paper reports the unintended consequences of their introduction. It describes how the test engendered trust in the professional competence of DSVs; was misconstrued by clients and providers as enabling a more definitive diagnosis of disease...

  19. The Comparison of Biochemical and Sequencing 16S rDNA Gene Methods to Identify Nontuberculous Mycobacteria

    Directory of Open Access Journals (Sweden)

    Shafipour1, M.

    2014-11-01

    Full Text Available The identification of Mycobacteria in the species level has great medical importance. Biochemical tests are laborious and time-consuming, so new techniques could be used to identify the species. This research aimed to the comparison of biochemical and sequencing 16S rDNA gene methods to identify nontuberculous Mycobacteria in patients suspected to tuberculosis in Golestan province which is the most prevalent region of tuberculosis in Iran. Among 3336 patients suspected to tuberculosis referred to hospitals and health care centres in Golestan province during 2010-2011, 319 (9.56% culture positive cases were collected. Identification of species by using biochemical tests was done. On the samples recognized as nontuberculous Mycobacteria, after DNA extraction by boiling, 16S rDNA PCR was done and their sequencing were identified by NCBI BLAST. Of the 319 positive samples in Golestan Province, 300 cases were M.tuberculosis and 19 cases (5.01% were identified as nontuberculous Mycobacteria by biochemical tests. 15 out of 19 nontuberculous Mycobacteria were identified by PCR and sequencing method as similar by biochemical methods (similarity rate: 78.9%. But after PCR, 1 case known as M.simiae by biochemical test was identified as M. lentiflavum and 3 other cases were identified as Nocardia. Biochemical methods corresponded to the 16S rDNA PCR and sequencing in 78.9% of cases. However, in identification of M. lentiflavum and Nocaria sp. the molecular method is better than biochemical methods.

  20. Rapid diagnostic tests for typhoid and paratyphoid (enteric) fever.

    Science.gov (United States)

    Wijedoru, Lalith; Mallett, Sue; Parry, Christopher M

    2017-05-26

    Differentiating both typhoid (Salmonella Typhi) and paratyphoid (Salmonella Paratyphi A) infection from other causes of fever in endemic areas is a diagnostic challenge. Although commercial point-of-care rapid diagnostic tests (RDTs) for enteric fever are available as alternatives to the current reference standard test of blood or bone marrow culture, or to the widely used Widal Test, their diagnostic accuracy is unclear. If accurate, they could potentially replace blood culture as the World Health Organization (WHO)-recommended main diagnostic test for enteric fever. To assess the diagnostic accuracy of commercially available rapid diagnostic tests (RDTs) and prototypes for detecting Salmonella Typhi or Paratyphi A infection in symptomatic persons living in endemic areas. We searched the Cochrane Infectious Diseases Group Specialized Register, MEDLINE, Embase, Science Citation Index, IndMED, African Index Medicus, LILACS, ClinicalTrials.gov, and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) up to 4 March 2016. We manually searched WHO reports, and papers from international conferences on Salmonella infections. We also contacted test manufacturers to identify studies. We included diagnostic accuracy studies of enteric fever RDTs in patients with fever or with symptoms suggestive of enteric fever living in endemic areas. We classified the reference standard used as either Grade 1 (result from a blood culture and a bone marrow culture) or Grade 2 (result from blood culture and blood polymerase chain reaction, or from blood culture alone). Two review authors independently extracted the test result data. We used a modified QUADAS-2 extraction form to assess methodological quality. We performed a meta-analysis when there were sufficient studies for the test and heterogeneity was reasonable. Thirty-seven studies met the inclusion criteria and included a total of 5080 participants (range 50 to 1732). Enteric fever prevalence

  1. Extra pulmonary tuberculosis: Rapid identification of Mycobacterium tuberculosis grown in Mycobacterium growth indicator tube 960 and Lowenstein-Jensen media, employing Standard diagnostics Bioline Mycobacterium tuberculosis protein 64 antigen detection kit

    Directory of Open Access Journals (Sweden)

    G Kandhakumari

    2015-01-01

    Full Text Available Background: Investigation of extra pulmonary tuberculosis (EPTB in and around Pondicherry is being carried out since August 2011 in our tertiary care super specialty hospital. Objectives: To compare the rapid Kit SD Bio-Line MPT 64 Ag with conventional and time consuming biochemical tests. Confirmation of Mycobacterium tuberculosis at a reasonable time frame is the main thrust. Materials and Methods: Thirty three Mycobacterium tuberculosis and four Non-Tuberculous Mycobacteria (NTM grown in MGIT960 system/Lowenstein-Jensen media (LJ were examined by the rapid MPT 64 antigen detection as well as a battery of conventional tests like niacin, nitrate reduction, paraminobenzoic acid susceptibility and cord formation. Results and Conclusion: . Both the rapid kit and conventional tests correctly identified 33 M.tuberculosis isolates. Keeping conventional identification as reference, sensitivity and specificity for rapid kit was 100%. Rapid kit which takes only 15 minutes is accurate, cost effective, and facilitates early treatment for these EPTB patients, whose clinical specimens are paucibacillary.

  2. Mobile Image Ratiometry: A New Method for Instantaneous Analysis of Rapid Test Strips

    OpenAIRE

    Donald C. Cooper; Bryan Callahan; Phil Callahan; Lee Burnett

    2012-01-01

    Here we describe Mobile Image Ratiometry (MIR), a new method for the automated quantification of standardized rapid immunoassay strips using consumer-based mobile smartphone and tablet cameras. To demonstrate MIR we developed a standardized method using rapid immunotest strips directed against cocaine (COC) and its major metabolite, benzoylecgonine (BE). We performed image analysis of three brands of commercially available dye-conjugated anti-COC/BE antibody test strips in response to three d...

  3. Rapid screening for lipid storage disorders using biochemical markers. Expert center data and review of the literature.

    Science.gov (United States)

    Voorink-Moret, M; Goorden, S M I; van Kuilenburg, A B P; Wijburg, F A; Ghauharali-van der Vlugt, J M M; Beers-Stet, F S; Zoetekouw, A; Kulik, W; Hollak, C E M; Vaz, F M

    2018-02-01

    In patients suspected of a lipid storage disorder (sphingolipidoses, lipidoses), confirmation of the diagnosis relies predominantly on the measurement of specific enzymatic activities and genetic studies. New UPLC-MS/MS methods have been developed to measure lysosphingolipids and oxysterols, which, combined with chitotriosidase activity may represent a rapid first tier screening for lipid storage disorders. A lysosphingolipid panel consisting of lysoglobotriaosylceramide (LysoGb3), lysohexosylceramide (LysoHexCer: both lysoglucosylceramide and lysogalactosylceramide), lysosphingomyelin (LysoSM) and its carboxylated analogue lysosphingomyelin-509 (LysoSM-509) was measured in control subjects and plasma samples of predominantly untreated patients affected with lipid storage disorders (n=74). In addition, the oxysterols cholestane-3β,5α,6β-triol and 7-ketocholesterol were measured in a subset of these patients (n=36) as well as chitotriosidase activity (n=43). A systematic review of the literature was performed to assess the usefulness of these biochemical markers. Specific elevations of metabolites, i.e. without overlap between controls and other lipid storage disorders, were found for several lysosomal storage diseases: increased LysoSM levels in acid sphingomyelinase deficiency (Niemann-Pick disease type A/B), LysoGb3 levels in males with classical phenotype Fabry disease and LysoHexCer (i.e. lysoglucosylceramide/lysogalactosylceramide) in Gaucher and Krabbe diseases. While elevated levels of LysoSM-509 and cholestane-3β,5α,6β-triol did not discriminate between Niemann Pick disease type C and acid sphingomyelinase deficiency, LysoSM-509/LysoSM ratio was specifically elevated in Niemann-Pick disease type C. In Gaucher disease type I, mild increases in several lysosphingolipids were found including LysoGb3 with levels in the range of non-classical Fabry males and females. Chitotriosidase showed specific elevations in symptomatic Gaucher disease, and was mildly

  4. [Non-animal toxicology in the safety testing of chemicals].

    Science.gov (United States)

    Heinonen, Tuula; Tähti, Hanna

    2013-01-01

    There is an urgent need to develop predictive test methods better than animal experiments for assessing the safety of chemical substances to man. According to today's vision this is achieved by using human cell based tissue and organ models. In the new testing strategy the toxic effects are assessed by the changes in the critical parameters of the cellular biochemical routes (AOP, adverse toxic outcome pathway-principle) in the target tissues. In vitro-tests are rapid and effective, and with them automation can be applied. The change in the testing paradigm is supported by all stakeholders: scientists, regulators and people concerned on animal welfare.

  5. Effect of sweet yeast bread formula on evaluating rapid mix test

    Directory of Open Access Journals (Sweden)

    Petra Dvořáková

    2011-01-01

    Full Text Available The aim of this work was to detect how different sweet yeast bread formulas influence results of rapid mix test and by the help of sensory analysis to discover consumer preferences and possible benefit and use in bakery industry. Applied raw materials (ground wheat flour T 530, yeast, sugar, salt, oil, egg, improver Hit along with basic formula were taken from the Varmužova bakery in Boršice by Buchlovice. The basic formula served as a standard (I, other six formulas were then determined (II–VII. In each formula, the rate of yeast, sugar or oil was altered in the range of ± 10% compared with the standard. Flour bread-making quality – Hagberg Falling number [s], Sedimentation index [ml], wet gluten [%], ash [%], moisture [%], binding capacity [%], granulation [%], alveographic energy [10−4J] and alveographic rate P/L – was measured. Rapid mix test and parameters like pastry weight, volume, shape, dough yield, pastry yield, baking loss, penetration and sensory analysis were determined. To establish yeast fermentation activity, Engelke fermentation test was applied. The most evident differences among the samples appeared in the volume and shape. The results of sensory analysis showed that the samples with higher rate of altered raw materials were evaluated as the best.

  6. Rapid prototyping of centrifugal microfluidic modules for point of care blood testing

    CSIR Research Space (South Africa)

    Madzivhandila, Phophi

    2016-11-01

    Full Text Available We present modular centrifugal microfluidic devices that enable a series of blood tests to be performed towards a full blood count. The modular approach allows for rapid prototyping of device components in a generic format to complete different...

  7. A Lateral Flow Rapid Test for Human Toxocariasis Developed Using Three Toxocara canis Recombinant Antigens.

    Science.gov (United States)

    Yunus, Muhammad Hafiznur; Tan Farrizam, Siti Naqiuyah; Abdul Karim, Izzati Zahidah; Noordin, Rahmah

    2018-01-01

    Laboratory diagnosis of toxocariasis is still a challenge especially in developing endemic countries with polyparasitism. In this study, three Toxocara canis recombinant antigens, rTES-26, rTES-30, and rTES-120, were expressed and used to prepare lateral flow immunoglobulin G4 (IgG4) dipsticks. The concordance of the results of the rapid test (comprising three dipsticks) with a commercial IgG-enzyme-linked immunosorbent assay (ELISA) (Cypress Diagnostics, Belgium) was compared against the concordance of two other commercial IgG-ELISA kits (Bordier, Switzerland and NovaTec, Germany) with the Cypress kit. Using Toxocara- positive samples, the concordance of the dipstick dotted with rTES-26, rTES-30, and rTES-120 was 41.4% (12/29), 51.7% (15/29), and 72.4% (21/29), respectively. When positivity with any dipstick was considered as an overall positive rapid test result, the concordance with the Cypress kit was 93% (27/29). Meanwhile, when compared with the results of the Cypress kit, the concordance of IgG-ELISA from NovaTec and Bordier was 100% (29/29) and 89.7% (26/29), respectively. Specific IgG4 has been recognized as a marker of active infection for several helminthic diseases; therefore, the two non-concordant results of the rapid test when compared with the NovaTec IgG-ELISA kit may be from samples of people with non-active infection. All the three dipsticks showed 100% (50/50) concordance with the Cypress kit when tested with serum from individuals who were healthy and with other infections. In conclusion, the lateral flow rapid test is potentially a good, fast, and easy test for toxocariasis. Next, further validation studies and development of a test with the three antigens in one dipstick will be performed.

  8. Operational feasibility of using whole blood in the rapid HIV testing algorithm of a resource-limited settings like Bangladesh.

    Science.gov (United States)

    Munshi, Saif U; Oyewale, Tajudeen O; Begum, Shahnaz; Uddin, Ziya; Tabassum, Shahina

    2016-03-01

    Serum-based rapid HIV testing algorithm in Bangladesh constitutes operational challenge to scaleup HIV testing and counselling (HTC) in the country. This study explored the operational feasibility of using whole blood as alternative to serum for rapid HIV testing in Bangladesh. Whole blood specimens were collected from two study groups. The groups included HIV-positive patients (n = 200) and HIV-negative individuals (n = 200) presenting at the reference laboratory in Dhaka, Bangladesh. The specimens were subjected to rapid HIV tests using the national algorithm with A1 = Alere Determine (United States), A2 = Uni-Gold (Ireland), and A3 = First Response (India). The sensitivity and specificity of the test results, and the operational cost were compared with current serum-based testing. The sensitivities [95% of confidence interval (CI)] for A1, A2, and A3 tests using whole blood were 100% (CI: 99.1-100%), 100% (CI: 99.1-100%), and 97% (CI: 96.4-98.2%), respectively, and specificities of all test kits were 100% (CI: 99.1-100%). Significant (P < 0.05) reduction in the cost of establishing HTC centre and consumables by 94 and 61%, respectively, were observed. The cost of administration and external quality assurance reduced by 39 and 43%, respectively. Overall, there was a 36% cost reduction in total operational cost of rapid HIV testing with blood when compared with serum. Considering the similar sensitivity and specificity of the two specimens, and significant cost reduction, rapid HIV testing with whole blood is feasible. A review of the national HIV rapid testing algorithm with whole blood will contribute toward improving HTC coverage in Bangladesh.

  9. BioCluster: Tool for Identification and Clustering of Enterobacteriaceae Based on Biochemical Data

    Directory of Open Access Journals (Sweden)

    Ahmed Abdullah

    2015-06-01

    Full Text Available Presumptive identification of different Enterobacteriaceae species is routinely achieved based on biochemical properties. Traditional practice includes manual comparison of each biochemical property of the unknown sample with known reference samples and inference of its identity based on the maximum similarity pattern with the known samples. This process is labor-intensive, time-consuming, error-prone, and subjective. Therefore, automation of sorting and similarity in calculation would be advantageous. Here we present a MATLAB-based graphical user interface (GUI tool named BioCluster. This tool was designed for automated clustering and identification of Enterobacteriaceae based on biochemical test results. In this tool, we used two types of algorithms, i.e., traditional hierarchical clustering (HC and the Improved Hierarchical Clustering (IHC, a modified algorithm that was developed specifically for the clustering and identification of Enterobacteriaceae species. IHC takes into account the variability in result of 1–47 biochemical tests within this Enterobacteriaceae family. This tool also provides different options to optimize the clustering in a user-friendly way. Using computer-generated synthetic data and some real data, we have demonstrated that BioCluster has high accuracy in clustering and identifying enterobacterial species based on biochemical test data. This tool can be freely downloaded at http://microbialgen.du.ac.bd/biocluster/.

  10. Accuracy in HIV Rapid Testing among Laboratory and Non-laboratory Personnel in Zambia: Observations from the National HIV Proficiency Testing System.

    Directory of Open Access Journals (Sweden)

    Sheila Mwangala

    Full Text Available Despite rapid task-shifting and scale-up of HIV testing services in high HIV prevalence countries, studies evaluating accuracy remain limited. This study aimed to assess overall accuracy level and factors associated with accuracy in HIV rapid testing in Zambia.Accuracy was investigated among rural and urban HIV testing sites participating in two annual national HIV proficiency testing (PT exercises conducted in 2009 (n = 282 sites and 2010 (n = 488 sites. Testers included lay counselors, nurses, laboratory personnel and others. PT panels of five dry tube specimens (DTS were issued to testing sites by the national reference laboratory (NRL. Site accuracy level was assessed by comparison of reported results to the expected results. Non-parametric rank tests and multiple linear regression models were used to assess variation in accuracy between PT cycles and between tester groups, and to examine factors associated with accuracy respectively.Overall accuracy level was 93.1% (95% CI: 91.2-94.9 in 2009 and 96.9% (95% CI: 96.1-97.8 in 2010. Differences in accuracy were seen between the tester groups in 2009 with laboratory personnel being more accurate than non-laboratory personnel, while in 2010 no differences were seen. In both PT exercises, lay counselors and nurses had more difficulties interpreting results, with more occurrences of false-negative, false-positive and indeterminate results. Having received the standard HIV rapid testing training and adherence to the national HIV testing algorithm were positively associated with accuracy.The study showed an improvement in tester group and overall accuracy from the first PT exercise to the next. Average number of incorrect test results per 1000 tests performed was reduced from 69 to 31. Further improvement is needed, however, and the national HIV proficiency testing system seems to be an important tool in this regard, which should be continued and needs to be urgently strengthened.

  11. Specificity of the Acute Tryptophan and Tyrosine Plus Phenylalanine Depletion and Loading Tests I. Review of Biochemical Aspects and Poor Specificity of Current Amino Acid Formulations

    Directory of Open Access Journals (Sweden)

    Abdulla A.-B. Badawy

    2010-06-01

    Full Text Available The acute tryptophan or tyrosine plus phenylalanine depletion and loading tests are powerful tools for studying the roles of serotonin, dopamine and noradrenaline in normal subjects and those with behavioural disorders. The current amino acid formulations for these tests, however, are associated with undesirable decreases in ratios of tryptophan or tyrosine plus phenylalanine to competing amino acids resulting in loss of specificity. This could confound biochemical and behavioural findings. Compositions of current formulations are reviewed, the biochemical principles underpinning the tests are revisited and examples of unintended changes in the above ratios and their impact on monoamine function and behaviour will be demonstrated from data in the literature. The presence of excessive amounts of the 3 branched-chain amino acids Leu, Ile and Val is responsible for these unintended decreases and the consequent loss of specificity. Strategies for enhancing the specificity of the different formulations are proposed.

  12. Specificity of the Acute Tryptophan and Tyrosine plus Phenylalanine Depletion and Loading Tests I. Review of Biochemical Aspects and Poor Specificity of Current Amino Acid Formulations

    Directory of Open Access Journals (Sweden)

    Abdulla A.-B. Badawy

    2010-01-01

    Full Text Available The acute tryptophan or tyrosine plus phenylalanine depletion and loading tests are powerful tools for studying the roles of serotonin, dopamine and noradrenaline in normal subjects and those with behavioural disorders. The current amino acid formulations for these tests, however, are associated with undesirable decreases in ratios of tryptophan or tyrosine plus phenylalanine to competing amino acids resulting in loss of specificity. This could confound biochemical and behavioural findings. Compositions of current formulations are reviewed, the biochemical principles underpinning the tests are revisited and examples of unintended changes in the above ratios and their impact on monoamine function and behaviour will be demonstrated from data in the literature. The presence of excessive amounts of the 3 branched-chain amino acids Leu, Ile and Val is responsible for these unintended decreases and the consequent loss of specificity. Strategies for enhancing the specificity of the different formulations are proposed.

  13. Evaluation of the Verigene Gram-positive blood culture nucleic acid test for rapid detection of bacteria and resistance determinants.

    Science.gov (United States)

    Wojewoda, Christina M; Sercia, Linda; Navas, Maria; Tuohy, Marion; Wilson, Deborah; Hall, Geraldine S; Procop, Gary W; Richter, Sandra S

    2013-07-01

    Rapid identification of pathogens from blood cultures can decrease lengths of stay and improve patient outcomes. We evaluated the accuracy of the Verigene Gram-positive blood culture (BC-GP) nucleic acid test for investigational use only (Nanosphere, Inc., Northbrook, IL) for the identification of Gram-positive bacteria from blood cultures. The detection of resistance genes (mecA in Staphylococcus aureus and Staphylococcus epidermidis and vanA or vanB in Enterococcus faecium and Enterococcus faecalis) by the BC-GP assay also was assessed. A total of 186 positive blood cultures (in BacT/Alert FA bottles) with Gram-positive cocci observed with Gram staining were analyzed using the BC-GP assay. The BC-GP results were compared with the identification and susceptibility profiles obtained with routine methods in the clinical laboratory. Discordant results were arbitrated with additional biochemical, cefoxitin disk, and repeat BC-GP testing. The initial BC-GP organism identification was concordant with routine method results for 94.6% of the blood cultures. Only 40% of the Streptococcus pneumoniae identifications were correct. The detection of the mecA gene for 69 blood cultures with only S. aureus or S. epidermidis was concordant with susceptibility testing results. For 3 of 6 cultures with multiple Staphylococcus spp., mecA detection was reported but was correlated with oxacillin resistance in a species other than S. aureus or S. epidermidis. The detection of vanA agreed with susceptibility testing results for 45 of 46 cultures with E. faecalis or E. faecium. Comparison of the mean times to results for each organism group showed that BC-GP results were available 31 to 42 h earlier than phenotypic identifications and 41 to 50 h earlier than susceptibility results.

  14. Biochemical activity of fullerenes and related derivatives

    International Nuclear Information System (INIS)

    Huczko, A.; Lange, H.; Calko, E.

    1999-01-01

    An astonishing scientific interest, embodied in over 15000 research articles so far, has been encountered since 1985 when fullerenes were discovered. From new superconductors to a rich electrochemistry and reaction chemistry, fullerene nanostructures continue to excite the scientific world, and new findings continue at record pace. This review presents many examples of the biochemical activities of fullerenes and derivatives, e. g. cytotoxic activity, selective DNA cleavage and antiviral activity against HIV. We also present some results of our testing which show that, despite its chemical and biochemical activity, fullerene matter does not present any health hazard directly related to skin irritation and allergic risks. (author)

  15. Rapid Point-of-Care Diagnostic Test for Syphilis in High-Risk Populations, Manaus, Brazil

    OpenAIRE

    Sabid?, Meritxell; Benzaken, Adele S.; de Andrade Rodrigues, ?nio Jos?; Mayaud, Philippe

    2009-01-01

    : We assessed the acceptability and operational suitability of a rapid point-of-care syphilis test and identified barriers to testing among high-risk groups and healthcare professionals in a sexually transmitted infections clinic in Manaus, Brazil. Use of this test could considerably alleviate the impact of syphilis in hard-to-reach populations in the Amazon region of Brazil.

  16. Antimicrobial susceptibility testing of rapidly growing mycobacteria by microdilution - Experience of a tertiary care centre

    Directory of Open Access Journals (Sweden)

    Set R

    2010-01-01

    Full Text Available Purpose: The objective of the study was to perform antimicrobial susceptibility testing of rapidly growing mycobacteria (RGM isolated from various clinically suspected cases of extrapulmonary tuberculosis, from January 2007 to April 2008, at a tertiary care centre in Mumbai. Materials and Methods: The specimens were processed for microscopy and culture using the standard procedures. Minimum inhibitory concentrations (MIC were determined by broth microdilution, using Sensititre CA MHBT. Susceptibility testing was also carried out on Mueller Hinton agar by the Kirby Bauer disc diffusion method. Results: Of the 1062 specimens received for mycobacterial cultures, 104 (9.79% grew mycobacteria. Of the mycobacterial isolates, six (5.76% were rapid growers. M. abscessus and M. chelonae appeared to be resistant organisms, with M. chelonae showing intermediate resistance to amikacin and minocycline. However, all the six isolates showed sensitivity to vancomycin and gentamicin by the disc diffusion test. Also all three isolates of M. abscessus were sensitive to piperacillin and erythromycin. Further studies are required to test their sensitivity to these four antimicrobials by using the microbroth dilution test, before they can be prescribed to patients. Conclusions: We wish to emphasize that reporting of rapidly growing mycobacteria from clinical settings, along with their sensitivity patterns, is an absolute need of the hour.

  17. Behavioral and biochemical effects of ketamine and dextromethorphan relative to its antidepressant-like effects in Swiss Webster mice.

    Science.gov (United States)

    Nguyen, Linda; Lucke-Wold, Brandon P; Logsdon, Aric F; Scandinaro, Anna L; Huber, Jason D; Matsumoto, Rae R

    2016-09-28

    Ketamine has been shown to produce rapid and robust antidepressant effects in depressed individuals; however, its abuse potential and adverse psychotomimetic effects limit its widespread use. Dextromethorphan (DM) may serve as a safer alternative on the basis of pharmacodynamic similarities to ketamine. In this proof-of-concept study, behavioral and biochemical analyses were carried out to evaluate the potential involvement of brain-derived neurotrophic factor (BDNF) in the antidepressant-like effects of DM in mice, with comparisons to ketamine and imipramine. Male Swiss, Webster mice were injected with DM, ketamine, or imipramine and their behaviors were evaluated in the forced-swim test and the open-field test. Western blots were used to measure BDNF and its precursor, pro-BDNF, protein expression in the hippocampus and the frontal cortex of these mice. Our results show that both DM and imipramine reduced immobility time in the forced-swim test without affecting locomotor activity, whereas ketamine reduced immobility time and increased locomotor activity. Ketamine also rapidly (within 40 min) increased pro-BDNF expression in an α-amino-3-hydroxy-5-methyl-4-isoxazolepropionic acid receptor-dependent manner in the hippocampus, whereas DM and imipramine did not alter pro-BDNF or BDNF levels in either the hippocampus or the frontal cortex within this timeframe. These data show that DM shares some features with both ketamine and imipramine. Additional studies examining DM may aid in the development of more rapid, safe, and efficacious antidepressant treatments.

  18. A high frequency test bench for rapid single-flux-quantum circuits

    International Nuclear Information System (INIS)

    Engseth, H; Intiso, S; Rafique, M R; Tolkacheva, E; Kidiyarova-Shevchenko, A

    2006-01-01

    We have designed and experimentally verified a test bench for high frequency testing of rapid single-flux-quantum (RSFQ) circuits. This test bench uses an external tunable clock signal that is stable in amplitude, phase and frequency. The high frequency external clock reads out the clock pattern stored in a long shift register. The clock pattern is consequently shifted out at high speed and split to feed both the circuit under test and an additional shift register in the test bench for later verification at low speed. This method can be employed for reliable high speed verification of RSFQ circuit operation, with use of only low speed read-out electronics. The test bench consists of 158 Josephson junctions and the occupied area is 3300 x 660 μm 2 . It was experimentally verified up to 33 GHz with ± 21.7% margins on the global bias supply current

  19. Rapid antigen detection test for respiratory syncytial virus diagnosis as a diagnostic tool

    Directory of Open Access Journals (Sweden)

    Flávio da Silva Mesquita

    2017-05-01

    Full Text Available Objective: The aim of this study was to evaluate the QuickVue® RSV Test Kit (QUIDEL Corp, CA, USA as a screening tool for respiratory syncytial virus in children with acute respiratory disease in comparison with the indirect immunofluorescence assay as gold standard. In Brazil, rapid antigen detection tests for respiratory syncytial virus are not routinely utilized as a diagnostic tool, except for the diagnosis of dengue and influenza. Methods: The authors retrospectively analyzed 486 nasopharyngeal aspirate samples from children under age 5 with acute respiratory infection, between December 2013 and August 2014, the samples were analyzed by indirect immunofluorescence assay and QuickVue® RSV Test kit. Samples with discordant results were analyzed by real time PCR and nucleotide sequencing. Results: From 313 positive samples by immunofluorescence assays, 282 (90% were also positive by the rapid antigen detection test, two were positive only by rapid antigen detection test, 33 were positive only by immunofluorescence assays, and 171 were positive by both methods. The 35 samples with discordant results were analyzed by real time PCR; the two samples positive only by rapid antigen detection test and the five positive only by immunofluorescence assays were also positive by real time PCR. There was no relation between the negativity by QuickVue® RSV Test and viral load or specific strain. The QuickVue® RSV Test showed sensitivity of 90%, specificity of 98.8%, predictive positive value of 99.3%, and negative predictive value of 94.6%, with accuracy of 93.2% and agreement κ index of 0.85 in comparison to immunofluorescence assay. Conclusions: This study demonstrated that the QuickVue® RSV Test Kit can be effective in early detection of Respiratory syncytial virus in nasopharyngeal aspirate and is reliable for use as a diagnostic tool in pediatrics. Resumo: Objetivo: Avaliar o teste QuickVue® RSV Test Kit (QUIDEL Corp, CA, EUA para o diagn

  20. Is Serial Testing Required to Diagnose Imported Malaria in the Era of Rapid Diagnostic Tests?

    Science.gov (United States)

    Pasricha, Janet M.; Juneja, Surender; Manitta, Joseph; Whitehead, Susan; Maxwell, Ellen; Goh, Wai-Keong; Pasricha, Sant-Rayn; Eisen, Damon P.

    2013-01-01

    Exclusion of malaria traditionally requires three negative serial thick and thin blood films. However, many clinical laboratories now routinely perform rapid diagnostic tests (RDTs) in addition to blood films when malaria is suspected. We sought to determine whether serial testing is necessary in this setting. We examined 388 cases of malaria diagnosed during 1999–2010 at three laboratories in Melbourne, Australia. For each case, we ascertained whether the diagnosis was made on initial or follow-up testing. Nine cases (3.5%) were diagnosed after a negative initial blood film and RDT: 7 Plasmodium vivax, 1 P. ovale, and 1 P. falciparum. Of four case-patients with P. vivax in which clinical data were available, all had recent exposure to antimalarial medication. Our data suggest that among patients who have not received recent anti-malarial therapy, and when RDTs are performed and blood films are prepared, most malaria diagnoses are made by using the first set of tests. PMID:23208885

  1. Influence of the applied voltage on the Rapid Chloride Migration (RCM) test

    NARCIS (Netherlands)

    Spiesz, P.R.; Brouwers, H.J.H.

    2012-01-01

    This study addresses the influence of the applied voltage (electrical field) on the value of the chloride migration coefficient, as determined with the Rapid Chloride Migration (RCM) test, and on other properties of cement based mortars. It is shown that in the investigated ranges of applied

  2. Development of rapid phenotypic system for the identification of Gram-negative oxidase-positive bacilli in resource-limited settings.

    Science.gov (United States)

    Kazmi, Mahmooda; Khan, Adnan; Kazmi, Shahana Urooj

    2013-06-01

    Rapid and accurate identification of bacterial pathogens is a fundamental goal of clinical microbiology. The diagnosis and surveillance of diseases is dependent, to a great extent, on laboratory services, which cannot function without effective reliable reagents and diagnostics. Despite the advancement in microbiology diagnosis globally, resourcelimited countries still struggle to provide an acceptable diagnosis quality which helps in clinical disease management and improve their mortality and morbidity data. During this study an indigenous product, Quick Test Strip (QTS) NE, was developed for the rapid identification of biochemically slower group of Gram-negative oxidase-positive bacilli that covers 19 different bacterial genera. Some of the members belonging to these groups are well-established human pathogens, e.g. various species of Vibrio, Pseudomonas, Burkholderia, Aeromonas, Achromobacter and Stenotrophomonas. This study also evaluates the performance of QTS-NE by comparing with genotypic characterization methods. A total of 232 clinical and reference bacterial isolates were tested by three different methods. QTSNE provides 100 percent concordant results with other rapid identification and molecular characterization methods and confirms the potential to be used in clinical diagnosis.

  3. EU-approved rapid tests for bovine spongiform encephalopathy detect atypical forms: a study for their sensitivities.

    Directory of Open Access Journals (Sweden)

    Daniela Meloni

    Full Text Available Since 2004 it become clear that atypical bovine spongiform encephalopthies (BSEs exist in cattle. Whenever their detection has relied on active surveillance plans implemented in Europe since 2001 by rapid tests, the overall and inter-laboratory performance of these diagnostic systems in the detection of the atypical strains has not been studied thoroughly to date. To fill this gap, the present study reports on the analytical sensitivity of the EU-approved rapid tests for atypical L- and H-type and classical BSE in parallel. Each test was challenged with two dilution series, one created from a positive pool of the three BSE forms according to the EURL standard method of homogenate preparation (50% w/v and the other as per the test kit manufacturer's instructions. Multilevel logistic models and simple logistic models with the rapid test as the only covariate were fitted for each BSE form analyzed as directed by the test manufacturer's dilution protocol. The same schemes, but excluding the BSE type, were then applied to compare test performance under the manufacturer's versus the water protocol. The IDEXX HerdChek ® BSE-scrapie short protocol test showed the highest sensitivity for all BSE forms. The IDEXX® HerdChek BSE-scrapie ultra short protocol, the Prionics®--Check WESTERN and the AJ Roboscreen® BetaPrion tests showed similar sensitivities, followed by the Roche® PrionScreen, the Bio-Rad® TeSeE™ SAP and the Prionics®--Check PrioSTRIP in descending order of analytical sensitivity. Despite these differences, the limit of detection of all seven rapid tests against the different classes of material set within a 2 log(10 range of the best-performing test, thus meeting the European Food Safety Authority requirement for BSE surveillance purposes. These findings indicate that not many atypical cases would have been missed surveillance since 2001 which is important for further epidemiological interpretations of the sporadic character of

  4. Elevation of PSA after prostate radiotherapy: Rebound or biochemical recurrence?

    International Nuclear Information System (INIS)

    Toledano, A.; Kanoui, A.; Chiche, R.; Lamallem, H.; Beley, S.; Thibault, F.; Sebe, P.

    2008-01-01

    The fact that external beam radiotherapy and brachytherapy are now considered to be curative techniques has led to major review of the modalities of follow-up after radiotherapy for prostate cancer. The problem concerns both the diagnosis of recurrence, rapidly announced by elevation of prostatic-specific antigen (PSA), usually at a subclinical stage, and the validity of criteria of biochemical recurrence to allow comparison of various study. Physicians involved in follow-up should be aware of the potential of bounce in PSA follow-up after external beam radiotherapy or brachytherapy. The PSA bounce phenomenon was defined by a rise of PSA values (+ 0.1 -0.8 ng/ml) with a subsequent fall. Biochemical failure after external beam radiotherapy or brachytherapy (with or without hormonotherapy) was defined by Phoenix criteria by a rise of 2 ng/ml above an initial PSA nadir. This definition was more correlated to PSA bounce phenomenon. (authors)

  5. The sensitivity and the specifity of rapid antigen test in streptococcal upper respiratory tract infections.

    Science.gov (United States)

    Gurol, Yesim; Akan, Hulya; Izbirak, Guldal; Tekkanat, Zuhal Tazegun; Gunduz, Tehlile Silem; Hayran, Osman; Yilmaz, Gulden

    2010-06-01

    It is aimed to detect the sensitivity and specificity of rapid antigen detection of group A beta hemolytic streptococci from throat specimen compared with throat culture. The other goal of the study is to help in giving clinical decisions in upper respiratory tract infections according to the age group, by detection of sensitivity and positive predictive values of the rapid tests and throat cultures. Rapid antigen detection and throat culture results for group A beta hemolytic streptococci from outpatients attending to our university hospital between the first of November 2005 and 31st of December 2008 were evaluated retrospectively. Throat samples were obtained by swabs from the throat and transported in the Stuart medium and Quickvue Strep A [Quidel, San Diego, USA] cassette test was applied and for culture, specimen was inoculated on 5% blood sheep agar and identified according to bacitracin and trimethoprim-sulphametaxazole susceptibility from beta hemolytic colonies. During the dates between the first of November 2005 and 31st of December 2008, from 453 patients both rapid antigen detection and throat culture were evaluated. Rapid antigen detection sensitivity and specificity were found to be 64.6% and 96.79%, respectively. The positive predictive value was 80.95% whereas negative predictive value was 92.82%. Kappa index was 0.91. When the results were evaluated according to the age groups, the sensitivity and the positive predictive value of rapid antigen detection in children were 70%, 90.3% and in adults 59.4%, 70.4%. When bacterial infection is concerned to prevent unnecessary antibiotic use, rapid streptococcal antigen test (RSAT) is a reliable method to begin immediate treatment. To get the maximum sensitivity of RSAT, the specimen collection technique used and education of the health care workers is important. While giving clinical decision, it must be taken into consideration that the sensitivity and the positive predictive value of the RSAT is quite

  6. Highly sensitive multianalyte immunochromatographic test strip for rapid chemiluminescent detection of ractopamine and salbutamol

    International Nuclear Information System (INIS)

    Gao, Hongfei; Han, Jing; Yang, Shijia; Wang, Zhenxing; Wang, Lin; Fu, Zhifeng

    2014-01-01

    Graphical abstract: A multianalyte immunochromatographic test strip was developed for the rapid detection of two β 2 -agonists. Due to the application of chemiluminescent detection, this quantitative method shows much higher sensitivity. - Highlights: • An immunochromatographic test strip was developed for detection of multiple β 2 -agonists. • The whole assay process can be completed within 20 min. • The proposed method shows much higher sensitivity due to the application of CL detection. • It is a portable analytical tool suitable for field analysis and rapid screening. - Abstract: A novel immunochromatographic assay (ICA) was proposed for rapid and multiple assay of β 2 -agonists, by utilizing ractopamine (RAC) and salbutamol (SAL) as the models. Owing to the introduction of chemiluminescent (CL) approach, the proposed protocol shows much higher sensitivity. In this work, the described ICA was based on a competitive format, and horseradish peroxidase-tagged antibodies were used as highly sensitive CL probes. Quantitative analysis of β 2 -agonists was achieved by recording the CL signals of the probes captured on the two test zones of the nitrocellulose membrane. Under the optimum conditions, RAC and SAL could be detected within the linear ranges of 0.50–40 and 0.10–50 ng mL −1 , with the detection limits of 0.20 and 0.040 ng mL −1 (S/N = 3), respectively. The whole process for multianalyte immunoassay of RAC and SAL can be completed within 20 min. Furthermore, the test strip was validated with spiked swine urine samples and the results showed that this method was reliable in measuring β 2 -agonists in swine urine. This CL-based multianalyte test strip shows a series of advantages such as high sensitivity, ideal selectivity, simple manipulation, high assay efficiency and low cost. Thus, it opens up new pathway for rapid screening and field analysis, and shows a promising prospect in food safety

  7. Highly sensitive multianalyte immunochromatographic test strip for rapid chemiluminescent detection of ractopamine and salbutamol

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Hongfei; Han, Jing; Yang, Shijia; Wang, Zhenxing; Wang, Lin; Fu, Zhifeng, E-mail: fuzf@swu.edu.cn

    2014-08-11

    Graphical abstract: A multianalyte immunochromatographic test strip was developed for the rapid detection of two β{sub 2}-agonists. Due to the application of chemiluminescent detection, this quantitative method shows much higher sensitivity. - Highlights: • An immunochromatographic test strip was developed for detection of multiple β{sub 2}-agonists. • The whole assay process can be completed within 20 min. • The proposed method shows much higher sensitivity due to the application of CL detection. • It is a portable analytical tool suitable for field analysis and rapid screening. - Abstract: A novel immunochromatographic assay (ICA) was proposed for rapid and multiple assay of β{sub 2}-agonists, by utilizing ractopamine (RAC) and salbutamol (SAL) as the models. Owing to the introduction of chemiluminescent (CL) approach, the proposed protocol shows much higher sensitivity. In this work, the described ICA was based on a competitive format, and horseradish peroxidase-tagged antibodies were used as highly sensitive CL probes. Quantitative analysis of β{sub 2}-agonists was achieved by recording the CL signals of the probes captured on the two test zones of the nitrocellulose membrane. Under the optimum conditions, RAC and SAL could be detected within the linear ranges of 0.50–40 and 0.10–50 ng mL{sup −1}, with the detection limits of 0.20 and 0.040 ng mL{sup −1} (S/N = 3), respectively. The whole process for multianalyte immunoassay of RAC and SAL can be completed within 20 min. Furthermore, the test strip was validated with spiked swine urine samples and the results showed that this method was reliable in measuring β{sub 2}-agonists in swine urine. This CL-based multianalyte test strip shows a series of advantages such as high sensitivity, ideal selectivity, simple manipulation, high assay efficiency and low cost. Thus, it opens up new pathway for rapid screening and field analysis, and shows a promising prospect in food safety.

  8. A Microfluidic Channel Method for Rapid Drug-Susceptibility Testing of Pseudomonas aeruginosa.

    Directory of Open Access Journals (Sweden)

    Yoshimi Matsumoto

    Full Text Available The recent global increase in the prevalence of antibiotic-resistant bacteria and lack of development of new therapeutic agents emphasize the importance of selecting appropriate antimicrobials for the treatment of infections. However, to date, the development of completely accelerated drug susceptibility testing methods has not been achieved despite the availability of a rapid identification method. We proposed an innovative rapid method for drug susceptibility testing for Pseudomonas aeruginosa that provides results within 3 h. The drug susceptibility testing microfluidic (DSTM device was prepared using soft lithography. It consisted of five sets of four microfluidic channels sharing one inlet slot, and the four channels are gathered in a small area, permitting simultaneous microscopic observation. Antimicrobials were pre-introduced into each channel and dried before use. Bacterial suspensions in cation-adjusted Mueller-Hinton broth were introduced from the inlet slot and incubated for 3 h. Susceptibilities were microscopically evaluated on the basis of differences in cell numbers and shapes between drug-treated and control cells, using dedicated software. The results of 101 clinically isolated strains of P. aeruginosa obtained using the DSTM method strongly correlated with results obtained using the ordinary microbroth dilution method. Ciprofloxacin, meropenem, ceftazidime, and piperacillin caused elongation in susceptible cells, while meropenem also induced spheroplast and bulge formation. Morphological observation could alternatively be used to determine the susceptibility of P. aeruginosa to these drugs, although amikacin had little effect on cell shape. The rapid determination of bacterial drug susceptibility using the DSTM method could also be applicable to other pathogenic species, and it could easily be introduced into clinical laboratories without the need for expensive instrumentation.

  9. Kato-Katz and Lumbreras rapid sedimentation test to evaluate helminth prevalence in the setting of a school-based deworming program

    Science.gov (United States)

    Lopez, Martha; Morales, Maria Luisa; Konana, Monisha; Hoyer, Paige; Pineda-Reyes, Roberto; White, Arthur Clinton; Garcia, Hector Hugo; Lescano, Andres Guillermo; Gotuzzo, Eduardo; Cabada, Miguel Mauricio

    2016-01-01

    The sensitivity of the Kato-Katz test is suboptimal for the evaluation of intestinal helminth prevalence. Moreover, during mass deworming, as helminth egg burden decreases, the sensitivity is likely to decrease. The Lumbreras rapid sedimentation (Lumbreras) is a low-cost non-quantitative test, but may provide useful information in low burden areas. We compared the prevalence of intestinal helminth infections assessed by the Kato-Katz and the Lumbreras rapid sedimentation test on 3 stool specimens from each of 1083 children. The sensitivities were compared using the McNemar paired test. Using the combined outcome of the 3 different stool tests as the standard, Kato-Katz had lower sensitivity than Lumbreras rapid sedimentation tests for Ascaris lumbricoides (85.1% vs. 95.1%, p = 0.03), Hymenolepis nana (77.7% vs. 97.9%, p Lumbreras rapid sedimentation tests enables the detection of more intestinal helminths infections in post-deworming low prevalence areas. PMID:27376503

  10. Pharmacogenetics of clopidogrel: comparison between a standard and a rapid genetic testing.

    Science.gov (United States)

    Saracini, Claudia; Vestrini, Anna; Galora, Silvia; Armillis, Alessandra; Abbate, Rosanna; Giusti, Betti

    2012-06-01

    CYP2C19 variant alleles are independent predictors of clopidogrel response variability and occurrence of major adverse cardiovascular events in high-risk vascular patients on clopidogrel therapy. Increasing evidence suggests a combination of platelet function testing with CYP2C19 genetic testing may be more effective in identifying high-risk individuals for alternative antiplatelet therapeutic strategies. A crucial point in evaluating the use of these polymorphisms in clinical practice, besides test accuracy, is the cost of the genetic test and rapid availability of the results. One hundred acute coronary syndrome patients were genotyped for CYP2C19*2,*3,*4,*5, and *17 polymorphisms with two platforms: Verigene(®) and the TaqMan(®) system. Genotyping results obtained by the classical TaqMan approach and the rapid Verigene approach showed a 100% concordance for all the five polymorphisms investigated. The Verigene system had shorter turnaround time with respect to TaqMan. The cost of reagents for TaqMan genotyping was lower than that for the Verigene system, but the effective manual staff involvement and the relative cost resulted in higher cost for TaqMan than for Verigene. The Verigene system demonstrated good performance in terms of turnaround time and cost for the evaluation of the clopidogrel poor metabolizer status, giving genetic information in suitable time (206 min) for a therapeutic strategy decision.

  11. Seroprevalence of brucellosis and associated hemato-biochemical changes in pakistani horses

    International Nuclear Information System (INIS)

    Gul, S.T.; Khan, A.; Ahmad, M.

    2013-01-01

    The aim of this study was to determine the seroprevalence and hemato-biochemical manifestations of brucellosis in horses. Serum samples were screened for Brucella antibodies by Rose Bengal plate test (RBPT) and serum agglutination test (SAT). Blood samples were evaluated for hemato-biochemical parameters following standard procedures. Results indicated seroprevalence of brucellosis 20.13 and 16.23% in horses by RBPT and SAT, respectively. Brucellosis does not lead to any significant change in hematological and biochemical parameters in relation to age, sex, body condition and lactation except few parameters. The values of erythrocyte sedimentation rate, neutrophil, basophil and alkaline phosphatase significantly decreased in brucellosis positive animals as compared to healthy animals whereas lymphocytes and alanine aminotransferase were in opposite order. It was concluded from the results that prevalence of brucellosis in horse population is of concern; therefore, control measures should be opted so that its zoonotic threat is curtailed. (author)

  12. Discordant results between biochemical and molecular transthyretin

    Indian Academy of Sciences (India)

    Discordant results between biochemical and molecular transthyretin assays: lessons learned from a unique testing algorithm at the Mayo Clinic. Honey V. Reddi Brittany C. Thomas Kurt S. Willkomm Matthew J. Ferber Kandelaria M. Rumilla Kimiyo M. Raymond John F. O'Brien W. Edward Highsmith. Research Note Volume ...

  13. Antigen detection of rabies virus in brain smear using direct Rapid Immunohistochemistry Test

    Directory of Open Access Journals (Sweden)

    Damayanti R

    2014-03-01

    Full Text Available Rabies is zoonotic disease caused by a fatal, neurotropic virus. Rabies virus is classified into the Genus of Lyssavirus under the yang family of Rhabdoviridae. Rabies affecting hot- blooded animals, as well as human. Dogs, cats, monkeys are the vectors or reservoirs for rabies and the virus was transmitted through the saliva after infected animal’s bites. The aim of this study was to conduct rapid diagnosis to detect rabies viral antigen in brain smear using immunohistochemical (IHC method namely direct Rapid Immunohistochemical Test (dRIT. A total number of 119 brain samples were achieved from Bukittinggi Veterinary Laboratory, West Sumatra. Standardisation and validation of the method were compared to Fluorescent Antibody Test (FAT as a golden standard for rabies diagnosis. Results show that dRIT was a very good method, it can be performed within two hours without the need of fluorescent microscope. The samples were tested using FAT and from 119 samples tested, 80 (67.23% samples were positive for rabies and 39 (32.77% samples were negative for rabies whereas using dRIT showed that 78 (65.54% samples were positive for rabies and 41 (34.45% samples were negative for rabies. The dRIT results were validated by comparing them with FAT results as a golden standard for rabies. The relative sensitivity of dRIT to FAT was 97.5% and the relative specificity to FAT was 100% (with Kappa value of 0.976, stated as excellent. The achievement showed that dRIT is very potential diagnostic tool and is highly recommended to be used widely as a rapid diagnosis tool for rabies.

  14. Recent Advances on the Use of Biochemical Extracts as Filaricidal Agents

    Directory of Open Access Journals (Sweden)

    Nazeh M. Al-Abd

    2013-01-01

    Full Text Available Lymphatic filariasis is a parasitic infection that causes a devastating public health and socioeconomic burden with an estimated infection of over 120 million individuals worldwide. The infection is caused by three closely related nematode parasites, namely, Wuchereria bancrofti, Brugia malayi, and B. timori, which are transmitted to human through mosquitoes of Anopheles, Culex, and Aedes genera. The species have many ecological variants and are diversified in terms of their genetic fingerprint. The rapid spread of the disease and the genetic diversification cause the lymphatic filarial parasites to respond differently to diagnostic and therapeutic interventions. This in turn prompts the current challenge encountered in its management. Furthermore, most of the chemical medications used are characterized by adverse side effects. These complications urgently warrant intense prospecting on bio-chemicals that have potent efficacy against either the filarial worms or thier vector. In lieu of this, we presented a review on recent literature that reported the efficacy of filaricidal biochemicals and those employed as vector control agents. In addition, methods used for biochemical extraction, screening procedures, and structure of the bioactive compounds were also presented.

  15. Clinical Evaluation of Rapid Diagnostic Test Kit for Scrub Typhus with Improved Performance.

    Science.gov (United States)

    Kim, Young-Jin; Park, Sungman; Premaratna, Ranjan; Selvaraj, Stephen; Park, Sang-Jin; Kim, Sora; Kim, Donghwan; Kim, Min Soo; Shin, Dong Hoon; Choi, Kyung-Chan; Kwon, Soon-Hwan; Seo, Wonjun; Lee, Nam Taek; Kim, Seung-Han; Kang, Heui Keun; Kim, Yoon-Won

    2016-08-01

    Diagnosis of scrub typhus is challenging due to its more than twenty serotypes and the similar clinical symptoms with other acute febrile illnesses including leptospirosis, murine typhus and hemorrhagic fever with renal syndrome. Accuracy and rapidity of a diagnostic test to Orientia tsutsugamushi is an important step to diagnose this disease. To discriminate scrub typhus from other diseases, the improved ImmuneMed Scrub Typhus Rapid Diagnostic Test (RDT) was evaluated in Korea and Sri Lanka. The sensitivity at the base of each IgM and IgG indirect immunofluorescent assay (IFA) in Korean patients was 98.6% and 97.1%, and the specificity was 98.2% and 97.7% respectively. The sensitivity and specificity for retrospective diagnosis at the base of IFA in Sri Lanka was 92.1% and 96.1%. ImmuneMed RDT was not reactive to any serum from seventeen diseases including hemorrhagic fever with renal syndrome (n = 48), leptospirosis (n = 23), and murine typhus (n = 48). ImmuneMed RDT shows superior sensitivity (98.6% and 97.1%) compared with SD Bioline RDT (84.4% at IgM and 83.3% at IgG) in Korea. The retrospective diagnosis of ImmuneMed RDT exhibits 94.0% identity with enzyme-linked Immunosorbent assay (ELISA) using South India patient serum samples. These results suggest that this RDT can replace other diagnostic tests and is applicable for global diagnosis of scrub typhus. This rapid and accurate diagnosis will be beneficial for diagnosing and managing scrub typhus.

  16. BALL - biochemical algorithms library 1.3

    Directory of Open Access Journals (Sweden)

    Stöckel Daniel

    2010-10-01

    Full Text Available Abstract Background The Biochemical Algorithms Library (BALL is a comprehensive rapid application development framework for structural bioinformatics. It provides an extensive C++ class library of data structures and algorithms for molecular modeling and structural bioinformatics. Using BALL as a programming toolbox does not only allow to greatly reduce application development times but also helps in ensuring stability and correctness by avoiding the error-prone reimplementation of complex algorithms and replacing them with calls into the library that has been well-tested by a large number of developers. In the ten years since its original publication, BALL has seen a substantial increase in functionality and numerous other improvements. Results Here, we discuss BALL's current functionality and highlight the key additions and improvements: support for additional file formats, molecular edit-functionality, new molecular mechanics force fields, novel energy minimization techniques, docking algorithms, and support for cheminformatics. Conclusions BALL is available for all major operating systems, including Linux, Windows, and MacOS X. It is available free of charge under the Lesser GNU Public License (LPGL. Parts of the code are distributed under the GNU Public License (GPL. BALL is available as source code and binary packages from the project web site at http://www.ball-project.org. Recently, it has been accepted into the debian project; integration into further distributions is currently pursued.

  17. Comparison of patient comprehension of rapid HIV pre-test fundamentals by information delivery format in an emergency department setting

    Directory of Open Access Journals (Sweden)

    Clark Melissa A

    2007-09-01

    Full Text Available Abstract Background Two trials were conducted to compare emergency department patient comprehension of rapid HIV pre-test information using different methods to deliver this information. Methods Patients were enrolled for these two trials at a US emergency department between February 2005 and January 2006. In Trial One, patients were randomized to a no pre-test information or an in-person discussion arm. In Trial Two, a separate group of patients were randomized to an in-person discussion arm or a Tablet PC-based video arm. The video, "Do you know about rapid HIV testing?", and the in-person discussion contained identical Centers for Disease Control and Prevention-suggested pre-test information components as well as information on rapid HIV testing with OraQuick®. Participants were compared by information arm on their comprehension of the pre-test information by their score on a 26-item questionnaire using the Wilcoxon rank-sum test. Results In Trial One, 38 patients completed the no-information arm and 31 completed the in-person discussion arm. Of these 69 patients, 63.8% had twelve years or fewer of formal education and 66.7% had previously been tested for HIV. The mean score on the questionnaire for the in-person discussion arm was higher than for the no information arm (18.7 vs. 13.3, p ≤ 0.0001. In Trial Two, 59 patients completed the in-person discussion and 55 completed the video arms. Of these 114 patients, 50.9% had twelve years or fewer of formal education and 68.4% had previously been tested for HIV. The mean score on the questionnaire for the video arm was similar to the in-person discussion arm (20.0 vs. 19.2; p ≤ 0.33. Conclusion The video "Do you know about rapid HIV testing?" appears to be an acceptable substitute for an in-person pre-test discussion on rapid HIV testing with OraQuick®. In terms of adequately informing ED patients about rapid HIV testing, either form of pre-test information is preferable than for patients

  18. Evaluation of a new rapid lateral flow chromatography test for the diagnosis of Helicobacter Pylori

    International Nuclear Information System (INIS)

    Kaklikkaya, N.; Dinc, U.; Dabanca, Pinar A.; Aydin, F.; Erturk, M.; Akdogan, Remzi A.; Ozgur, O.; Uzun, Dogan Y.; Gungor, E.; Arslan, M.; Cobanoglu, U.

    2006-01-01

    The rapid, simple and non-invasive diagnosis of Helicobacter pylori (H. pylori) infection is important in implementing chemotherapy in appropriate manner, and in assessing persistent H. pylori infection after eradication therapy. The Immuno Card STAT HpSA kit (Meridian Bioscience, Europe) is a lateral flow chromatography test which utilizes a monoclonal anti-H. pylori antibody. In this study, we investigated the usefulness of the ImmunoCard STAT HpSA test before and after eradication therapy on patients referred to undergo upper gastrointestinal endoscopy. Sixty-five consecutive patients who were referred to undergo upper gastrointestinal endoscopy at the Department of Gastroenterology, Karadeniz Technical University Medical School, Turkey between February and August 2005 were included in this study. The ImmunoCard STAT HpSA was compared with 4 invasive tests (histology, gram staining, rapid urease test, and culture). The reference method was defined as positive when 2 of the 4 invasive tests were positive. A negative H. pylori status was considered when all 4 tests present concordant negative results. Overall, the ImmunoCard STAT HpSA test had 77.8% sensitivity, 79.3% specificity, 82.4% positive predictive value (PPV) and 74.2% negative predictive value (NPV) in all patients. With regard to pre-treatment values, the sensitivity was 70.6%, specificity 70.6%, PPV 100% and NPV 100% while on post-treatment group the sensitivity was 84.2%, specificity 64.7%, PPV 72.7% and NPV 78.6%. Our results indicate that the ImmunoCard STAT HpSA test is a rapid, simple, and helpful procedure not only to determine H. pylori infection but also to assess the success of eradication therapy. (author)

  19. Rapid antibiotic susceptibility testing in a microfluidic pH sensor.

    Science.gov (United States)

    Tang, Yanyan; Zhen, Li; Liu, Jingqing; Wu, Jianmin

    2013-03-05

    For appropriate selection of antibiotics in the treatment of pathogen infection, rapid antibiotic susceptibility testing (AST) is urgently needed in clinical practice. This study reports the utilization of a microfluidic pH sensor for monitoring bacterial growth rate in culture media spiked with different kinds of antibiotics. The microfluidic pH sensor was fabricated by integration of pH-sensitive chitosan hydrogel with poly(dimethylsiloxane) (PDMS) microfluidic channels. For facilitating the reflectometric interference spectroscopic measurements, the chitosan hydrogel was coated on an electrochemically etched porous silicon chip, which was used as the substrate of the microfluidic channel. Real-time observation of the pH change in the microchannel can be realized by Fourier transform reflectometric interference spectroscopy (FT-RIFS), in which the effective optical thickness (EOT) was selected as the optical signal for indicating the reversible swelling process of chitosan hydrogel stimulated by pH change. With this microfluidic pH sensor, we demonstrate that confinement of bacterial cells in a nanoliter size channel allows rapid accumulation of metabolic products and eliminates the need for long-time preincubation, thus reducing the whole detection time. On the basis of this technology, the whole bacterial growth curve can be obtained in less than 2 h, and consequently rapid AST can be realized. Compared with conventional methods, the AST data acquired from the bacterial growth curve can provide more detailed information for studying the antimicrobial behavior of antibiotics during different stages. Furthermore, the new technology also provides a convenient method for rapid minimal inhibition concentration (MIC) determination of individual antibiotics or the combinations of antibiotics against human pathogens that will find application in clinical and point-of-care medicine.

  20. Biochemical methane potential (BMP) of solid organic materials

    DEFF Research Database (Denmark)

    Raposo, Francisco; Fernández-Cegrí, V.; De la Rubia, M.A.

    2010-01-01

    This paper describes the results obtained for different participating research groups in an interlaboratory study related to the biochemical methane potential (BMP). In this research work, the full experimental conditions influencing the test such as inoculum, substrate characteristics and experi...

  1. Incorporating Direct Rapid Immunohistochemical Testing into Large-Scale Wildlife Rabies Surveillance

    Directory of Open Access Journals (Sweden)

    Kevin Middel

    2017-06-01

    Full Text Available Following an incursion of the mid-Atlantic raccoon variant of the rabies virus into southern Ontario, Canada, in late 2015, the direct rapid immunohistochemical test for rabies (dRIT was employed on a large scale to establish the outbreak perimeter and to diagnose specific cases to inform rabies control management actions. In a 17-month period, 5800 wildlife carcasses were tested using the dRIT, of which 307 were identified as rabid. When compared with the gold standard fluorescent antibody test (FAT, the dRIT was found to have a sensitivity of 100% and a specificity of 98.2%. Positive and negative test agreement was shown to be 98.3% and 99.1%, respectively, with an overall test agreement of 98.8%. The average cost to test a sample was $3.13 CAD for materials, and hands-on technical time to complete the test is estimated at 0.55 h. The dRIT procedure was found to be accurate, fast, inexpensive, easy to learn and perform, and an excellent tool for monitoring the progression of a wildlife rabies incursion.

  2. Craniometaphyseal dysplasia with obvious biochemical abnormality and rickets-like features.

    Science.gov (United States)

    Wu, Bo; Jiang, Yan; Wang, Ou; Li, Mei; Xing, Xiao-Ping; Xia, Wei-Bo

    2016-05-01

    Craniometaphyseal dysplasia (CMD) is a rare genetic disorder that is characterized by progressive sclerosis of the craniofacial bones and metaphyseal widening of long bones, and biochemical indexes were mostly normal. To further the understanding of the disease from a biochemical perspective, we reported a CMD case with obviously abnormal biochemical indexes. A 1-year-old boy was referred to our clinic. Biochemical test showed obviously increased alkaline phosphatase (ALP) and parathyroid hormone (PTH), mild hypocalcemia and hypophosphatemia. Moreover, significant elevated receptor activator of nuclear factor kappa-B ligand (RANKL) level, but normal β-C-terminal telopeptide of type I collagen (β-CTX) concentration were revealed. He was initially suspected of rickets, because the radiological examination also showed broadened epiphysis in his long bones. Supplementation with calcium and calcitriol alleviated biochemical abnormality. However, the patient gradually developed osteosclerosis which was inconformity with rickets. Considering that he was also presented with facial paralysis and nasal obstruction symptom, the diagnosis of craniometaphyseal dysplasia was suspected, and then was confirmed by the mutation analysis of ANKH of the proband and his family, which showed a de novo heterozygous mutation (C1124-1126delCCT) on exon 9. Our study revealed that obvious biochemical abnormality and rickets-like features might present as uncommon characteristics in CMD patients, and the calcium and calcitriol supplementation could alleviate biochemical abnormalities. Furthermore, although early osteoclast differentiation factor was excited in CMD patient, activity of osteoclast was still inert. Copyright © 2016. Published by Elsevier B.V.

  3. GAMBARAN PENGGUNAAN RAPID DIAGNOSTIC TEST PARASIT MALARIA DI DESA PASIRMUKTI KECAMATAN CINEAM KABUPATEN TASIKMALAYA

    Directory of Open Access Journals (Sweden)

    Hubullah Fuadzy

    2013-12-01

    Full Text Available Abstract. High mobility amongst mining workers, demanding officer of Cineam Public Health Center can perform rapid diagnosis to the workers. Nowadays, many techniques are developed to detect the early transmission of malaria, begins from the clinical to the molecular, one of that techniques are Rapid Diagnostic Tests (RDTs. This research has been conducted in the village of Pasirmukti district Cineam, Tasikmalaya in 2012. Objective of this paper is description RDT utilities as rapid diagnosing efforts on families who have family members as mine worker malaria endemic areas. Inclusion criteria for this study were family who have and do not have family members were working as workers in malaria-endemic areas at 2011 or 2012. Respondents were willing to participate in this study would be taken for examination RDT. Respondents were willing to participate in this study amounted to 256 people, and 5 of them positive Plasmodium malaria based on RDTs screening. Respondents who positive for malaria on RDTs test were 4 women with lower education background and work as a housewife, then a men with a background of secondary school education and are currently still as student. RDT is one of the malaria parasite tools which suitable for use in the Pasirmukti Village district Cineam - Tasikmalaya. However, keep in mind on how to storage and use in order to avoid errors both false-positive and false negatives test results.   Keywords: rapid diagnostic tests, malaria, Tasikmalaya Abstrak. Mobilitas yang tinggi penduduk Cineam  menuju wilayah pertambangan emas diluar pulau Jawa, menuntut tenaga kesehatan di Puskesmas Cineam dapat melakukan diagnosa dini penyakit malaria terhadap para pekerja tambang tersebut. Saat ini, banyak dikembangkan teknik untuk mendeteksi penularan penyakit malaria secara dini, mulai dari yang bersifat klinis hingga molekuler, diantaranya adalah Rapid Diagnostic Tests (RDTs. Untuk mengetahui gambaran pemanfaatan RDT di Cineam perlu

  4. The Charlie Sheen Effect on Rapid In-home Human Immunodeficiency Virus Test Sales.

    Science.gov (United States)

    Allem, Jon-Patrick; Leas, Eric C; Caputi, Theodore L; Dredze, Mark; Althouse, Benjamin M; Noar, Seth M; Ayers, John W

    2017-07-01

    One in eight of the 1.2 million Americans living with human immunodeficiency virus (HIV) are unaware of their positive status, and untested individuals are responsible for most new infections. As a result, testing is the most cost-effective HIV prevention strategy and must be accelerated when opportunities are presented. Web searches for HIV spiked around actor Charlie Sheen's HIV-positive disclosure. However, it is unknown whether Sheen's disclosure impacted offline behaviors like HIV testing. The goal of this study was to determine if Sheen's HIV disclosure was a record-setting HIV prevention event and determine if Web searches presage increases in testing allowing for rapid detection and reaction in the future. Sales of OraQuick rapid in-home HIV test kits in the USA were monitored weekly from April 12, 2014, to April 16, 2016, alongside Web searches including the terms "test," "tests," or "testing" and "HIV" as accessed from Google Trends. Changes in OraQuick sales around Sheen's disclosure and prediction models using Web searches were assessed. OraQuick sales rose 95% (95% CI, 75-117; p sales than expected around Sheen's disclosure, surpassing World AIDS Day by a factor of about 7. Moreover, Web searches mirrored OraQuick sales trends (r = 0.79), demonstrating their ability to presage increases in testing. The "Charlie Sheen effect" represents an important opportunity for a public health response, and in the future, Web searches can be used to detect and act on more opportunities to foster prevention behaviors.

  5. A Global Comparative Evaluation of Commercial Immunochromatographic Rapid Diagnostic Tests for Visceral Leishmaniasis

    NARCIS (Netherlands)

    Cunningham, Jane; Hasker, Epco; Das, Pradeep; El Safi, Sayda; Goto, Hiro; Mondal, Dinesh; Mbuchi, Margaret; Mukhtar, Maowia; Rabello, Ana; Rijal, Suman; Sundar, Shyam; Wasunna, Monique; Adams, Emily; Menten, Joris; Peeling, Rosanna; Boelaert, Marleen; Khanal, Basudha; Das, Murari; Oliveira, Edward; de Assis, Tália Machado; Costa, Dorcas Lamounier; Bhaskar, Khondaker Rifathassan; Huda, M. Mamun; Hassan, Mukidul; Abdoun, Asim Osman; Awad, Aymen; Osman, Mohamed; Prajapati, Dinesh Kumar; Gidwani, Kamlesh; Tiwary, Puja; Paniago, Anamaria Mello Miranda; Sanchez, Maria Carmen Arroyo; Celeste, Beatriz Julieta; Jacquet, Diane; Magiri, Charles; Muia, A.; Kesusu, J.; Ageed, Al Farazdag; Galal, Nuha; Osman, Osman Salih; Gupta, A. K.; Bimal, Afrad S.; Das, V. N. R.

    2012-01-01

    Background. Poor access to diagnosis stymies control of visceral leishmaniasis (VL). Antibody-detecting rapid diagnostic tests (RDTs) can be performed in peripheral health settings. However, there are many brands available and published reports of variable accuracy. Methods. Commercial VL RDTs

  6. Brief Report: Impact of Early Antiretroviral Therapy on the Performance of HIV Rapid Tests and HIV Incidence Assays.

    Science.gov (United States)

    Fogel, Jessica M; Piwowar-Manning, Estelle; Debevec, Barbara; Walsky, Tamara; Schlusser, Katherine; Laeyendecker, Oliver; Wilson, Ethan A; McCauley, Marybeth; Gamble, Theresa; Tegha, Gerald; Soko, Dean; Kumwenda, Johnstone; Hosseinipour, Mina C; Chen, Ying Q; Cohen, Myron S; Eshleman, Susan H

    2017-08-01

    Antiretroviral therapy (ART) can downregulate antibody responses to HIV infection. We evaluated the impact of early vs. delayed ART on the performance of HIV diagnostic and incidence assays. Samples were obtained from 207 participants in the HPTN 052 trial, who were stably suppressed on ART for ≥4 years [Malawi sites; pre-ART CD4 cell count 350-550 cells/mm (early ART arm, N = 180) or ART arm, N = 27)]. Samples were tested with 2 HIV rapid tests and 2 HIV incidence assays; selected samples were also tested with two fourth-generation immunoassays and a Western blot (WB) assay. A pre-ART sample was analyzed if the follow-up sample had a false-negative or weakly-reactive rapid test result, or had an incidence assay result indicative of recent infection (false-recent result). Ten (4.8%) samples had a nonreactive or weakly-reactive rapid test result (7/180 early ART arm, 3/27 delayed ART arm, P = 0.13); one sample had nonreactive fourth-generation assay results and 3 had indeterminate WBs. Forty (18.9%) samples had a false-recent incidence assay result; 16 (7.8%) had false-recent results with both incidence assays. Baseline samples had stronger rapid test and WB bands, higher fourth-generation assay signal-to-cutoff values, and fewer HIV incidence assay results indicative of recent infection. False-negative/weakly-reactive HIV rapid tests and false-recent HIV incidence assay results were observed in virally-suppressed individuals, regardless of pre-ART CD4 cell count. Downregulation of the antibody response to HIV infection in the setting of ART may impact population-level surveys of HIV prevalence and incidence.

  7. Using three-dimensional rapid prototyping in the design and development of orthopaedic screws in standardised pull-out tests.

    Science.gov (United States)

    Leslie, Laura Jane; Connolly, Ashley; Swadener, John G; Junaid, Sarah; Theivendran, Kanthan; Deshmukh, Subodh C

    2018-05-01

    The majority of orthopaedic screws are designed, tested and manufactured by existing orthopaedics companies and are predominantly developed with healthy bone in mind. The timescales and costs involved in the development of a new screw design, for example, for osteoporotic bone, are high. In this study, standard wood screws were used to analyse the concept of using three-dimensional printing, or rapid prototyping, as a viable stage of development in the design of a new bone screw. Six wood screws were reverse engineered and printed in polymeric material using stereolithography. Three of the designs were also printed in Ti6Al4V using direct metal laser sintering; however, these were not of sufficient quality to test further. Both the original metal screws (metal) and polymeric rapid prototyping screws were then tested using standard pull-out tests from low-density polyurethane blocks (Sawbones). Results showed the highest pull-out strengths for screws with the longest thread length and the smallest inner diameter. Of the six screw designs tested, five showed no more than a 17% variance between the metal and rapid prototyping results. A similar pattern of results was shown between the screw designs for both the metal and rapid prototyping screws in five of the six cases. While not producing fully comparable pull-out results to orthopaedic screws, the results from this study do provide evidence of the potential usefulness and cost-effectiveness of rapid prototyping in the early stages of design and testing of orthopaedic screws.

  8. Diagnosis of acute mononucleosis in emergency: comparison of rapid tests

    Directory of Open Access Journals (Sweden)

    Federica Scaggiante

    2011-09-01

    Full Text Available Epstein-Barr virus (EBV is a gammaherpesvirus that causes a number of clinical syndromes, including acute mononucleosis.Acute infection with EBV can vary widely with regard to the severity and presentation of illness, ranging from an asymptomatic infection to a serious, life-threatening version of mononucleosis with associated liver damage and splenomegaly. Additionally, other acute viral syndromes, including those caused by hepatitis viruses and cytomegalovirus (CMV, can lead to similar clinical syndromes. The variety of symptoms and the overlap with other viral infections underscore the importance of laboratory testing in the diagnosis of acute EBV-related disease.The purpose of this study was to evaluate the utility of an agglutination test for the detection of heterophile antibodies (Monotest and two EBV-specific rapid immunochromatographic tests (VCA-IgM and VCA-IgG/EBNA-IgG. Heterophile antibody determination is resulted to have not a real diagnostic utility for the low sensibility and specificity of the test. In our experience the only use of VCA-IgG/EBNA-IgG test is sufficient to discriminate between an acute mononucleosis and a past infection.

  9. Impact of the rapid antigen detection test in diagnosis and treatment of acute pharyngotonsillitis in a pediatric emergency room.

    Science.gov (United States)

    Cardoso, Débora Morais; Gilio, Alfredo Elias; Hsin, Shieh Huei; Machado, Beatriz Marcondes; de Paulis, Milena; Lotufo, João Paulo B; Martinez, Marina Baquerizo; Grisi, Sandra Josefina E

    2013-01-01

    To evaluate the impact of the routine use of rapid antigen detection test in the diagnosis and treatment of acute pharyngotonsillitis in children. This is a prospective and observational study, with a protocol compliance design established at the Emergency Unit of the University Hospital of Universidade de São Paulo for the care of children and adolescents diagnosed with acute pharyngitis. 650 children and adolescents were enrolled. Based on clinical findings, antibiotics would be prescribed for 389 patients (59.8%); using the rapid antigen detection test, they were prescribed for 286 patients (44.0%). Among the 261 children who would not have received antibiotics based on the clinical evaluation, 111 (42.5%) had positive rapid antigen detection test. The diagnosis based only on clinical evaluation showed 61.1% sensitivity, 47.7% specificity, 44.9% positive predictive value, and 57.5% negative predictive value. The clinical diagnosis of streptococcal pharyngotonsillitis had low sensitivity and specificity. The routine use of rapid antigen detection test led to the reduction of antibiotic use and the identification of a risk group for complications of streptococcal infection, since 42.5% positive rapid antigen detection test patients would not have received antibiotics based only on clinical diagnosis.

  10. Human anti-HIV IgM detection by the OraQuick ADVANCE® Rapid HIV 1/2 Antibody Test.

    Science.gov (United States)

    Guillon, Geraldine; Yearwood, Graham; Snipes, Casey; Boschi, Daniel; Reed, Michael R

    2018-01-01

    The Centers for Disease Control and Prevention (CDC) and many public health jurisdictions continue to advocate for the most sensitive rapid HIV test that is available. Currently, the recommendation is to utilize tests that can detect HIV infection biomarkers within 30 days of infection, when initial immune responses are mounted. The infected patient's IgM response is often used to detect acute infection within a 20-25 days window after infection. This requirement applies to lab-based testing with automated analyzers and rapid, point of care (POC) testing used for screening in a non-clinical setting. A recent study has demonstrated that POC tests using a Protein A-based detection system can detect samples with predominantly HIV-1 IgM reactivity (Moshgabadi et al., 2015). The OraQuick ADVANCE ® Rapid HIV-1/2 Antibody Test (OraQuick ADVANCE ®) also uses Protein A as the detection protein in the antibody-binding colloidal gold conjugate, so it is expected that the OraQuick ADVANCE ® Test will also detect samples with predominantly IgM reactivity. This report definitively demonstrates that the OraQuick ADVANCE ® Test can detect IgM antibodies during an acute infection window period of approximately 20-25 days after infection, and is therefore suitable for use in testing environments requiring adherence to current CDC recommendations.

  11. Rapid Antimicrobial Susceptibility Testing Using Forward Laser Light Scatter Technology.

    Science.gov (United States)

    Hayden, Randall T; Clinton, Lani K; Hewitt, Carolyn; Koyamatsu, Terri; Sun, Yilun; Jamison, Ginger; Perkins, Rosalie; Tang, Li; Pounds, Stanley; Bankowski, Matthew J

    2016-11-01

    The delayed reporting of antimicrobial susceptibility testing remains a limiting factor in clinical decision-making in the treatment of bacterial infection. This study evaluates the use of forward laser light scatter (FLLS) to measure bacterial growth for the early determination of antimicrobial susceptibility. Three isolates each (two clinical isolates and one reference strain) of Staphylococcus aureus, Escherichia coli, and Pseudomonas aeruginosa were tested in triplicate using two commercial antimicrobial testing systems, the Vitek2 and the MicroScan MIC panel, to challenge the BacterioScan FLLS. The BacterioScan FLLS showed a high degree of categorical concordance with the commercial methods. Pairwise comparison with each commercial system serving as a reference standard showed 88.9% agreement with MicroScan (two minor errors) and 72.2% agreement with Vitek (five minor errors). FLLS using the BacterioScan system shows promise as a novel method for the rapid and accurate determination of antimicrobial susceptibility. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  12. Vibrational spectroscopy as a probe to rapidly detect, identify, and characterize micro-organisms

    Science.gov (United States)

    Sockalingum, Ganesh D.; Lamfarraj, Hasnae; Beljebbar, Abdelilah; Pina, Patrick; Delavenne, Marc; Witthuhn, Fabienne; Allouch, Pierre; Manfait, Michel

    1999-04-01

    Fast and exact identification of a great number of microorganisms is becoming a serious challenge. Differentiation and identification of microorganisms is today mainly achieved by the use of a variety of distinct techniques based on morphological, serological aspects and a set of biochemical test. Vibrational spectroscopic techniques can be complementary and useful methods in this field due to their rapidity, 'fingerprinting' capabilities, and the molecular information that they can provide. Using SERS at Ag colloids, we have conducted pilot studies to rapidly detect and identify bacterial clinical strains. Using a Raman microspectrometer equipped with a He/Ne laser, a first attempt to record SERS spectra was made on colloidal solutions. Spectra were of good quality but not very reproducible due to the movement of the microorganisms. Strains were then put in presence of Ag colloids and direct on-plate analysis was performed. Spectra were more reproducible, with diminished fluorescence, and reveal characteristic cellular-level information. Different growth conditions and colloid preparations have been tested. Pseudomonas aeruginosa and Escherichia coli clinical strains, responsible for nosocomial infections, have been our first test samples. An attempt has also been made to record SERS data from gold colloids in view of future measurement in the near-IR. Spectroscopic data are compared with ATR-FTIR results.

  13. Test plan for preparing the Rapid Transuranic Monitoring Laboratory for field deployment

    International Nuclear Information System (INIS)

    McIsaac, C.V.; Sill, C.W.; Gehrke, R.J.; Killian, E.W.; Watts, K.D.

    1994-04-01

    This plan describes experimental work that will be performed during fiscal year 1994 to prepare the Rapid Transuranic Monitoring Laboratory (RTML) for routine field use by US Department of Energy (DOE) Environmental Restoration and Waste Management programs. The RTML is a mobile, field-deployable laboratory developed at the Idaho National Engineering Laboratory (INEL) that provides a rapid, cost-effective means of characterizing and monitoring radioactive waste remediation sites for low-level radioactive contaminants. Analytical instruments currently installed in the RTML include an extended-range, germanium photon analysis spectrometer with an automatic sample changer; two, large-area, ionization chamber alpha spectrometers; and four alpha continuous air monitors. The RTML was field tested at the INEL during June 1993 in conjunction with the Buried Waste Integrated Demonstration's remote retrieval demonstration. The major tasks described in this test plan are to (a) evaluate the beta detectors for use in screening soil samples for 90 Sr, (b) upgrade the alpha spectral analysis software programs, and (c) upgrade the photon spectral analysis software programs

  14. Diagnosis of rinderpest in Tanzania by a rapid chromatographic strip-test.

    Science.gov (United States)

    Wambura, P N; Moshy, D W; Mbise, A N; Mollel, G O; Taylor, W P; Anderson, J; Bruning, A

    2000-06-01

    A simple chromatographic strip-test based on Clearview technology, is under development as a pen-side test for the detection of rinderpest antigen in eye swabs taken from cattle in the field. An outbreak of rinderpest occurred in the northern zone of Tanzania from late February to June 1997. The affected cattle exhibited very mild clinical signs, which made clinical diagnosis difficult. One hundred and seven eye swabs were collected from cattle suspected of infection with rinderpest. These were tested in the field using a prototype of the pen-side test and 13 (12.15%) of the samples were found to be positive for the presence of rinderpest antigen. These were confirmed by ICE. The positive cases were predominantly found in the Ngorongoro district. This demonstrates the usefulness of such a simple, rapid pen-side diagnostic assay, particularly when clinically 'mild' strains of rinderpest are present.

  15. Impact of rapid molecular diagnostic tests on time to treatment initiation and outcomes in patients with multidrug-resistant tuberculosis, Tamil Nadu, India.

    Science.gov (United States)

    Nair, Dina; Navneethapandian, Pooranaganga D; Tripathy, Jaya Prasad; Harries, Anthony D; Klinton, Joel S; Watson, Basilea; Sivaramakrishnan, Gomathi N; Reddy, Devarajulu S; Murali, Lakshmi; Natrajan, Mohan; Swaminathan, Soumya

    2016-09-01

    India is replacing culture and drug sensitivity testing (CDST) with rapid molecular tests for diagnosing MDR-TB. We assessed the impact of rapid tests on time to initiation of treatment and outcomes in patients with MDR-TB compared with CDST. A retrospective cohort study involving MDR-TB patients from six districts in Tamil Nadu state, who underwent CDST (2010-2011) and rapid tests (2012-2013). There were 135 patients in the CDST group and 389 in the rapid diagnostic test group. Median time from sputum receipt at the laboratory to initiation of MDR-TB treatment was 130 days (IQR 75-213) in the CDST group and 22 days (IQR 14-38) in the rapid diagnostic test group (p30% in both groups and missing data were higher in CDST (13%) compared with rapid tests (3%). There were significantly higher risks of unfavourable treatment outcomes in males (aRR 1.3, 95% CI 1.1-1.5) and those with treatment initiation delays >30 days (aRR 1.3, 95% CI 1.0-1.6). Rapid molecular diagnostic tests shortened the time to initiate treatment which was associated with reduced unfavourable outcomes in MDR-TB patients. This supports the policy to scale up these tests in India. © The Author 2016. Published by Oxford University Press on behalf of Royal Society of Tropical Medicine and Hygiene. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  16. The evaluation of a rapid in situ HIV confirmation test in a programme with a high failure rate of the WHO HIV two-test diagnostic algorithm.

    Directory of Open Access Journals (Sweden)

    Derryck B Klarkowski

    Full Text Available BACKGROUND: Concerns about false-positive HIV results led to a review of testing procedures used in a Médecins Sans Frontières (MSF HIV programme in Bukavu, eastern Democratic Republic of Congo. In addition to the WHO HIV rapid diagnostic test algorithm (RDT (two positive RDTs alone for HIV diagnosis used in voluntary counselling and testing (VCT sites we evaluated in situ a practical field-based confirmation test against western blot WB. In addition, we aimed to determine the false-positive rate of the WHO two-test algorithm compared with our adapted protocol including confirmation testing, and whether weakly reactive compared with strongly reactive rapid test results were more likely to be false positives. METHODOLOGY/PRINCIPAL FINDINGS: 2864 clients presenting to MSF VCT centres in Bukavu during January to May 2006 were tested using Determine HIV-1/2 and UniGold HIV rapid tests in parallel by nurse counsellors. Plasma samples on 229 clients confirmed as double RDT positive by laboratory retesting were further tested using both WB and the Orgenics Immunocomb Combfirm HIV confirmation test (OIC-HIV. Of these, 24 samples were negative or indeterminate by WB representing a false-positive rate of the WHO two-test algorithm of 10.5% (95%CI 6.6-15.2. 17 of the 229 samples were weakly positive on rapid testing and all were negative or indeterminate by WB. The false-positive rate fell to 3.3% (95%CI 1.3-6.7 when only strong-positive rapid test results were considered. Agreement between OIC-HIV and WB was 99.1% (95%CI 96.9-99.9% with no false OIC-HIV positives if stringent criteria for positive OIC-HIV diagnoses were used. CONCLUSIONS: The WHO HIV two-test diagnostic algorithm produced an unacceptably high level of false-positive diagnoses in our setting, especially if results were weakly positive. The most probable causes of the false-positive results were serological cross-reactivity or non-specific immune reactivity. Our findings show that the OIC

  17. Rapid diagnostic testing for community-acquired pneumonia: can innovative technology for clinical microbiology be exploited?

    Science.gov (United States)

    Yu, Victor L; Stout, Janet E

    2009-12-01

    Two nonsynchronous events have affected the management of community-acquired pneumonia (CAP): spiraling empiricism for CAP and the "golden era" of clinical microbiology. The development of broad-spectrum antibiotics has led to widespread empiric use without ascertaining the etiology of the infecting microbe. Unfortunately, this approach clashes with the second event, which is the advent of molecular-based microbiology that can identify the causative pathogen rapidly at the point of care. The urinary antigen is a most effective rapid test that has allowed targeted therapy for Legionnaire disease at the point of care. The high specificity (> 90%) allows the clinician to administer appropriate anti-Legionella therapy based on a single rapid test; however, its low sensitivity (76%) means that a notable number of cases of Legionnaire disease will go undiagnosed if other tests, especially culture, are not performed. Further, culture for Legionella is not readily available. If a culture is not performed, epidemiologic identification of the source of the bacterium cannot be ascertained by molecular fingerprinting of the patient and the putative source strain. We recommend resurrection of the basic principles of infectious disease, which are to identify the microbial etiology of the infection and to use narrow, targeted antimicrobial therapy. To reduce antimicrobial overuse with subsequent antimicrobial resistance, these basic principles must be applied in concert with traditional and newer tests in the clinical microbiology laboratory.

  18. Detection of cut-off point for rapid automized naming test in good readers and dyslexics

    Directory of Open Access Journals (Sweden)

    Zahra Soleymani

    2014-01-01

    Full Text Available Background and Aim: Rapid automized naming test is an appropriate tool to diagnose learning disability even before teaching reading. This study aimed to detect the cut-off point of this test for good readers and dyslexics.Methods: The test has 4 parts including: objects, colors, numbers and letters. 5 items are repeated on cards randomly for 10 times. Children were asked to name items rapidly. We studied 18 dyslexic students and 18 age-matched good readers between 7 and 8 years of age at second and third grades of elementary school; they were recruited by non-randomize sampling into 2 groups: children with developmental dyslexia from learning disabilities centers with mean age of 100 months, and normal children with mean age of 107 months from general schools in Tehran. Good readers selected from the same class of dyslexics.Results: The area under the receiver operating characteristic curve was 0.849 for letter naming, 0.892 for color naming, 0.971 for number naming, 0.887 for picture naming, and 0.965 totally. The overall sensitivity and specificity was 1 and was 0.79, respectively. The highest sensitivity and specificity were related to number naming (1 and 0.90, respectively.Conclusion: Findings showed that the rapid automized naming test could diagnose good readers from dyslexics appropriately.

  19. Hepatitis B virus surface antigen and anti-hepatitis C virus rapid tests underestimate hepatitis prevalence among HIV-infected patients.

    Science.gov (United States)

    Hønge, Bl; Jespersen, S; Medina, C; Té, Ds; da Silva, Zj; Ostergaard, L; Laursen, Al; Wejse, C; Krarup, H; Erikstrup, C

    2014-10-01

    In the case of coinfection with HIV and hepatitis B virus (HBV) and/or hepatitis C virus (HCV), hepatic disease progression is often accelerated, with higher rates of liver cirrhosis and liver-related mortality. We aimed to evaluate the performance of the rapid tests used routinely to detect HBV surface antigen (HBsAg) and anti-HCV among HIV-infected patients in Guinea-Bissau. Blood samples from HIV-infected patients in Guinea-Bissau were stored after testing for HBsAg and anti-HCV with rapid tests. Samples were subsequently re-tested for HBsAg and anti-HCV in Denmark. Two rapid tests were used in Guinea-Bissau: HBsAg Strip Ref 2034 (VEDA.LAB, Alençon, France; sensitivity 62.3%; specificity 99.2%) and HEPA-SCAN (Bhat Bio-Tech, Bangalore, India; sensitivity 57.1%; specificity 99.7%). In the two tests the ability to obtain the correct outcome depended on the antigen and antibody concentrations, respectively. Sex, age, CD4 cell count and antiretroviral therapy status did not differ between false negative and true positive samples in either of the tests. The study is limited by a low number of anti-HCV positive samples. New diagnostic rapid tests should always be evaluated in the setting in which they will be used before implementation. © 2014 British HIV Association.

  20. Biochemical Indicators of Radiation Injury in Man. Proceedings of a Scientific Meeting

    International Nuclear Information System (INIS)

    1971-01-01

    After an organism has suffered a radiation insult, knowledge of the dose and localization of the exposure is of the greatest importance for the treatment of any radiation damage. Supplementary to the information obtained from physical dosimetry, data obtained by biochemical indicators can, on the basis of metabolic changes in the irradiated organism, help in making early diagnosis, in assessing the extent of the radiation injury, and making a prognosis. Biochemical tests under optimal conditions would not depend on the quality and distribution of the dose in the body and would also reflect the sensitivity of the individual organisms. The International Atomic Energy Agency and the World Health Organization convened a joint scientific meeting on Biochemical Indicators of Radiation Injury in Man in Paris-Le Vésinet, France, from 22 to 26 June 1970. The main purpose of the meeting was to discuss recent problems in determining which biochemical and metabolic changes occurring in irradiated organisms could be used as indicators of radiation injury and its extent, and could thus be of help in planning the proper treatment of the injured persons. During the meeting the results obtained with various biochemical indicators, and experimental techniques and laboratory methods used in this field, were evaluated and compared. Both research workers and clinicians were invited to participate at the meeting. They discussed the possible value of several tests, used successfully in experimental animals, for clinical application; ways of standardizing suitable tests; and mutual collaboration between laboratories and clinics. The outcome of their discussions is summarized in the conclusions and recommendations which are included in these Proceedings together with the papers presented

  1. GSMA: Gene Set Matrix Analysis, An Automated Method for Rapid Hypothesis Testing of Gene Expression Data

    Directory of Open Access Journals (Sweden)

    Chris Cheadle

    2007-01-01

    Full Text Available Background: Microarray technology has become highly valuable for identifying complex global changes in gene expression patterns. The assignment of functional information to these complex patterns remains a challenging task in effectively interpreting data and correlating results from across experiments, projects and laboratories. Methods which allow the rapid and robust evaluation of multiple functional hypotheses increase the power of individual researchers to data mine gene expression data more efficiently.Results: We have developed (gene set matrix analysis GSMA as a useful method for the rapid testing of group-wise up- or downregulation of gene expression simultaneously for multiple lists of genes (gene sets against entire distributions of gene expression changes (datasets for single or multiple experiments. The utility of GSMA lies in its flexibility to rapidly poll gene sets related by known biological function or as designated solely by the end-user against large numbers of datasets simultaneously.Conclusions: GSMA provides a simple and straightforward method for hypothesis testing in which genes are tested by groups across multiple datasets for patterns of expression enrichment.

  2. Towards eliminating systematic errors caused by the experimental conditions in Biochemical Methane Potential (BMP) tests

    Energy Technology Data Exchange (ETDEWEB)

    Strömberg, Sten, E-mail: sten.stromberg@biotek.lu.se [Department of Biotechnology, Lund University, Getingevägen 60, 221 00 Lund (Sweden); Nistor, Mihaela, E-mail: mn@bioprocesscontrol.com [Bioprocess Control, Scheelevägen 22, 223 63 Lund (Sweden); Liu, Jing, E-mail: jing.liu@biotek.lu.se [Department of Biotechnology, Lund University, Getingevägen 60, 221 00 Lund (Sweden); Bioprocess Control, Scheelevägen 22, 223 63 Lund (Sweden)

    2014-11-15

    Highlights: • The evaluated factors introduce significant systematic errors (10–38%) in BMP tests. • Ambient temperature (T) has the most substantial impact (∼10%) at low altitude. • Ambient pressure (p) has the most substantial impact (∼68%) at high altitude. • Continuous monitoring of T and p is not necessary for kinetic calculations. - Abstract: The Biochemical Methane Potential (BMP) test is increasingly recognised as a tool for selecting and pricing biomass material for production of biogas. However, the results for the same substrate often differ between laboratories and much work to standardise such tests is still needed. In the current study, the effects from four environmental factors (i.e. ambient temperature and pressure, water vapour content and initial gas composition of the reactor headspace) on the degradation kinetics and the determined methane potential were evaluated with a 2{sup 4} full factorial design. Four substrates, with different biodegradation profiles, were investigated and the ambient temperature was found to be the most significant contributor to errors in the methane potential. Concerning the kinetics of the process, the environmental factors’ impact on the calculated rate constants was negligible. The impact of the environmental factors on the kinetic parameters and methane potential from performing a BMP test at different geographical locations around the world was simulated by adjusting the data according to the ambient temperature and pressure of some chosen model sites. The largest effect on the methane potential was registered from tests performed at high altitudes due to a low ambient pressure. The results from this study illustrate the importance of considering the environmental factors’ influence on volumetric gas measurement in BMP tests. This is essential to achieve trustworthy and standardised results that can be used by researchers and end users from all over the world.

  3. Towards eliminating systematic errors caused by the experimental conditions in Biochemical Methane Potential (BMP) tests

    International Nuclear Information System (INIS)

    Strömberg, Sten; Nistor, Mihaela; Liu, Jing

    2014-01-01

    Highlights: • The evaluated factors introduce significant systematic errors (10–38%) in BMP tests. • Ambient temperature (T) has the most substantial impact (∼10%) at low altitude. • Ambient pressure (p) has the most substantial impact (∼68%) at high altitude. • Continuous monitoring of T and p is not necessary for kinetic calculations. - Abstract: The Biochemical Methane Potential (BMP) test is increasingly recognised as a tool for selecting and pricing biomass material for production of biogas. However, the results for the same substrate often differ between laboratories and much work to standardise such tests is still needed. In the current study, the effects from four environmental factors (i.e. ambient temperature and pressure, water vapour content and initial gas composition of the reactor headspace) on the degradation kinetics and the determined methane potential were evaluated with a 2 4 full factorial design. Four substrates, with different biodegradation profiles, were investigated and the ambient temperature was found to be the most significant contributor to errors in the methane potential. Concerning the kinetics of the process, the environmental factors’ impact on the calculated rate constants was negligible. The impact of the environmental factors on the kinetic parameters and methane potential from performing a BMP test at different geographical locations around the world was simulated by adjusting the data according to the ambient temperature and pressure of some chosen model sites. The largest effect on the methane potential was registered from tests performed at high altitudes due to a low ambient pressure. The results from this study illustrate the importance of considering the environmental factors’ influence on volumetric gas measurement in BMP tests. This is essential to achieve trustworthy and standardised results that can be used by researchers and end users from all over the world

  4. Estimating Biochemical Parameters of Tea (camellia Sinensis (L.)) Using Hyperspectral Techniques

    Science.gov (United States)

    Bian, M.; Skidmore, A. K.; Schlerf, M.; Liu, Y.; Wang, T.

    2012-07-01

    Tea (Camellia Sinensis (L.)) is an important economic crop and the market price of tea depends largely on its quality. This research aims to explore the potential of hyperspectral remote sensing on predicting the concentration of biochemical components, namely total tea polyphenols, as indicators of tea quality at canopy scale. Experiments were carried out for tea plants growing in the field and greenhouse. Partial least squares regression (PLSR), which has proven to be the one of the most successful empirical approach, was performed to establish the relationship between reflectance and biochemical concentration across six tea varieties in the field. Moreover, a novel integrated approach involving successive projections algorithms as band selection method and neural networks was developed and applied to detect the concentration of total tea polyphenols for one tea variety, in order to explore and model complex nonlinearity relationships between independent (wavebands) and dependent (biochemicals) variables. The good prediction accuracies (r2 > 0.8 and relative RMSEP < 10 %) achieved for tea plants using both linear (partial lease squares regress) and nonlinear (artificial neural networks) modelling approaches in this study demonstrates the feasibility of using airborne and spaceborne sensors to cover wide areas of tea plantation for in situ monitoring of tea quality cheaply and rapidly.

  5. A Survey on Use of Rapid Tests and Tuberculosis Diagnostic Practices by Primary Health Care Providers in South Africa: Implications for the Development of New Point-of-Care Tests.

    Directory of Open Access Journals (Sweden)

    Malika Davids

    Full Text Available Effective infectious disease control requires early diagnosis and treatment initiation. Point-of-care testing offers rapid turn-around-times, facilitating same day clinical management decisions. To maximize the benefits of such POC testing programs, we need to understand how rapid tests are used in everyday clinical practice.In this cross-sectional survey study, 400 primary healthcare providers in two cities in South Africa were interviewed on their use of rapid tests in general, and tuberculosis diagnostic practices, between September 2012 and June 2013. Public healthcare facilities were selected using probability-sampling techniques and private healthcare providers were randomly selected from the Health Professional Council of South Africa list. To ascertain differences between the two healthcare sectors 2-sample z-tests were used to compare sample proportions.The numbers of providers interviewed were equally distributed between the public (n = 200 and private sector (n = 200. The most frequently reported tests in the private sector include blood pressure (99.5%, glucose finger prick (89.5% and urine dipstick (38.5%; and in the public sector were pregnancy (100%, urine dipstick (100%, blood pressure (100%, glucose finger prick (99% and HIV rapid test (98%. The majority of TB testing occurs in the public sector, where significantly more providers prefer Xpert MTB/RIF assay, the designated clinical TB diagnostic tool by the national TB program, as compared to the private sector (87% versus 71%, p-value >0.0001. Challenges with regard to TB diagnosis included the long laboratory turn-around-time, difficulty in obtaining sputum samples and lost results. All providers indicated that a new POC test for TB should be rapid and cheap, have good sensitivity and specificity, ease of sample acquisition, detect drug-resistance and work in HIV-infected persons.The existing centralized laboratory services, poor quality assurance, and lack of staff capacity

  6. Relationship between obesity and biochemical markers in Brazilian adolescents

    Directory of Open Access Journals (Sweden)

    Alexandre Romero

    2014-03-01

    The aim of this study was to describe the prevalence of biochemical markers and associate with obesity in Brazilian adolescents enrolled in public schools in a rural area. The sample consisted of 199 adolescents between 10 to 14 years old from Piracicaba, Brazil. The obesity was measured by body mass index (BMI and according to the World Health Organization curves. We collected blood for biochemical markers analysis (total cholesterol, high density lipoprotein, low density lipoprotein, triacylglycerol, insulin and glycemia. Mann Whitney test was used to compare continuous variables between sexes. Chi-square test was used to compare proportions. To investigate the association between the independent variables and biochemical markers a multiple logistic regression model was performed. Among 199 adolescents, 23.1% was obese and 65.8% were insufficiently active. A high prevalence of dyslipidemia (71.4% was observed, whereas the low levels of high density lipoprotein (40.7% were the most prevalent. An association between obesity and undesirable values for high density lipoprotein, triacylglycerol and insulin resistance was found. Obese adolescents were less likely to present a desirable value for high density lipoprotein. It is understood that obesity is detrimental to metabolic profile and should be prevented and treated even in adolescence.

  7. Rapid identification of HPV 16 and 18 by multiplex nested PCR-immunochromatographic test.

    Science.gov (United States)

    Kuo, Yung-Bin; Li, Yi-Shuan; Chan, Err-Cheng

    2015-02-01

    Human papillomavirus (HPV) types 16 and 18 are known to be high-risk viruses that cause cervical cancer. An HPV rapid testing kit that could help physicians to make early and more informed decisions regarding patient care is needed urgently but not yet available. This study aimed to develop a multiplex nested polymerase chain reaction-immunochromatographic test (PCR-ICT) for the rapid identification of HPV 16 and 18. A multiplex nested PCR was constructed to amplify the HPV 16 and 18 genotype-specific L1 gene fragments and followed by ICT which coated with antibodies to identify rapidly the different PCR products. The type-specific gene regions of high-risk HPV 16 and 18 could be amplified successfully by multiplex nested PCR at molecular sizes of approximately 99 and 101bp, respectively. The capture antibodies raised specifically against the moleculars labeled on the PCR products could be detected simultaneously both HPV 16 and 18 in one strip. Under optimal conditions, this PCR-ICT assay had the capability to detect HPV in a sample with as low as 100 copies of HPV viral DNA. The PCR-ICT system has the advantage of direct and simultaneous detection of two high-risk HPV 16 and 18 DNA targets in one sample, which suggested a significant potential of this assay for clinical application. Copyright © 2014. Published by Elsevier B.V.

  8. Some biochemical studies on thyroid immunity

    International Nuclear Information System (INIS)

    Shoush, M.A.M.

    1980-01-01

    The present study was carried out to investigate the effect of induced immunological environment on: a - Carbohydrate metabolism as reflected by immunoreactive insulin and blood sugar levels. b - Biochemical parameters, namely total protein, albumin, globulin, alkaline phosphatase and transaminases, reflecting liver function. c - Radioimmunological tests reflecting thyroid function. The study comprised 36 male rabbits, boscate strain of six months age assigned randomly to : control, albumin immunized and thyroglobulin immunized groups

  9. Comparison of mid-infrared transmission spectroscopy with biochemical methods for the determination of macronutrients in human milk.

    Science.gov (United States)

    Silvestre, Dolores; Fraga, Miriam; Gormaz, María; Torres, Ester; Vento, Máximo

    2014-07-01

    The variability of human milk (HM) composition renders analysis of its components essential for optimal nutrition of preterm fed either with donor's or own mother's milk. To fulfil this requirement, various analytical instruments have been subjected to scientific and clinical evaluation. The objective of this study was to evaluate the suitability of a rapid method for the analysis of macronutrients in HM as compared with the analytical methods applied by cow's milk industry. Mature milk from 39 donors was analysed using an infrared human milk analyser (HMA) and compared with biochemical reference laboratory methods. The statistical analysis was based on the use of paired data tests. The use of an infrared HMA for the analysis of lipids, proteins and lactose in HM proved satisfactory as regards the rapidity, simplicity and the required sample volume. The instrument afforded good linearity and precision in application to all three nutrients. However, accuracy was not acceptable when compared with the reference methods, with overestimation of the lipid content and underestimation of the amount of proteins and lactose contents. The use of mid-infrared HMA might become the standard for rapid analysis of HM once standardisation and rigorous and systematic calibration is provided. © 2012 John Wiley & Sons Ltd.

  10. Rapid prototyping compliant arterial phantoms for in-vitro studies and device testing

    Directory of Open Access Journals (Sweden)

    Biglino Giovanni

    2013-01-01

    Full Text Available Abstract Background Compliant vascular phantoms are desirable for in-vitro patient-specific experiments and device testing. TangoPlus FullCure 930® is a commercially available rubber-like material that can be used for PolyJet rapid prototyping. This work aims to gather preliminary data on the distensibility of this material, in order to assess the feasibility of its use in the context of experimental cardiovascular modelling. Methods The descending aorta anatomy of a volunteer was modelled in 3D from cardiovascular magnetic resonance (CMR images and rapid prototyped using TangoPlus. The model was printed with a range of increasing wall thicknesses (0.6, 0.7, 0.8, 1.0 and 1.5 mm, keeping the lumen of the vessel constant. Models were also printed in both vertical and horizontal orientations, thus resulting in a total of ten specimens. Compliance tests were performed by monitoring pressure variations while gradually increasing and decreasing internal volume. Knowledge of distensibility was thus derived and then implemented with CMR data to test two applications. Firstly, a patient-specific compliant model of hypoplastic aorta suitable for connection in a mock circulatory loop for in-vitro tests was manufactured. Secondly, the right ventricular outflow tract (RVOT of a patient necessitating pulmonary valve replacement was printed in order to physically test device insertion and assess patient’s suitability for percutaneous pulmonary valve intervention. Results The distensibility of the material was identified in a range from 6.5 × 10-3 mmHg-1 for the 0.6 mm case, to 3.0 × 10-3 mmHg-1 for the 1.5 mm case. The models printed in the vertical orientation were always more compliant than their horizontal counterpart. Rapid prototyping of a compliant hypoplastic aorta and of a RVOT anatomical model were both feasible. Device insertion in the RVOT model was successful. Conclusion Values of distensibility, compared with literature data, show that Tango

  11. Rapid prototyping compliant arterial phantoms for in-vitro studies and device testing.

    Science.gov (United States)

    Biglino, Giovanni; Verschueren, Peter; Zegels, Raf; Taylor, Andrew M; Schievano, Silvia

    2013-01-16

    Compliant vascular phantoms are desirable for in-vitro patient-specific experiments and device testing. TangoPlus FullCure 930 is a commercially available rubber-like material that can be used for PolyJet rapid prototyping. This work aims to gather preliminary data on the distensibility of this material, in order to assess the feasibility of its use in the context of experimental cardiovascular modelling. The descending aorta anatomy of a volunteer was modelled in 3D from cardiovascular magnetic resonance (CMR) images and rapid prototyped using TangoPlus. The model was printed with a range of increasing wall thicknesses (0.6, 0.7, 0.8, 1.0 and 1.5 mm), keeping the lumen of the vessel constant. Models were also printed in both vertical and horizontal orientations, thus resulting in a total of ten specimens. Compliance tests were performed by monitoring pressure variations while gradually increasing and decreasing internal volume. Knowledge of distensibility was thus derived and then implemented with CMR data to test two applications. Firstly, a patient-specific compliant model of hypoplastic aorta suitable for connection in a mock circulatory loop for in-vitro tests was manufactured. Secondly, the right ventricular outflow tract (RVOT) of a patient necessitating pulmonary valve replacement was printed in order to physically test device insertion and assess patient's suitability for percutaneous pulmonary valve intervention. The distensibility of the material was identified in a range from 6.5 × 10(-3) mmHg(-1) for the 0.6 mm case, to 3.0 × 10(-3) mmHg(-1) for the 1.5 mm case. The models printed in the vertical orientation were always more compliant than their horizontal counterpart. Rapid prototyping of a compliant hypoplastic aorta and of a RVOT anatomical model were both feasible. Device insertion in the RVOT model was successful. Values of distensibility, compared with literature data, show that TangoPlus is suitable for manufacturing arterial phantoms, with

  12. Multifrequency Excitation Method for Rapid and Accurate Dynamic Test of Micromachined Gyroscope Chips

    Directory of Open Access Journals (Sweden)

    Yan Deng

    2014-10-01

    Full Text Available A novel multifrequency excitation (MFE method is proposed to realize rapid and accurate dynamic testing of micromachined gyroscope chips. Compared with the traditional sweep-frequency excitation (SFE method, the computational time for testing one chip under four modes at a 1-Hz frequency resolution and 600-Hz bandwidth was dramatically reduced from 10 min to 6 s. A multifrequency signal with an equal amplitude and initial linear-phase-difference distribution was generated to ensure test repeatability and accuracy. The current test system based on LabVIEW using the SFE method was modified to use the MFE method without any hardware changes. The experimental results verified that the MFE method can be an ideal solution for large-scale dynamic testing of gyroscope chips and gyroscopes.

  13. BISEN: Biochemical simulation environment

    NARCIS (Netherlands)

    Vanlier, J.; Wu, F.; Qi, F.; Vinnakota, K.C.; Han, Y.; Dash, R.K.; Yang, F.; Beard, D.A.

    2009-01-01

    The Biochemical Simulation Environment (BISEN) is a suite of tools for generating equations and associated computer programs for simulating biochemical systems in the MATLAB® computing environment. This is the first package that can generate appropriate systems of differential equations for

  14. Rapid Biochemical Mixture Screening by Three-Dimensional Patterned Multifunctional Substrate with Ultra-Thin Layer Chromatography (UTLC) and Surface Enhanced Raman Scattering (SERS).

    Science.gov (United States)

    Lee, Bi-Shen; Lin, Pi-Chen; Lin, Ding-Zheng; Yen, Ta-Jen

    2018-01-11

    We present a three-dimensional patterned (3DP) multifunctional substrate with the functions of ultra-thin layer chromatography (UTLC) and surface enhanced Raman scattering (SERS), which simultaneously enables mixture separation, target localization and label-free detection. This multifunctional substrate is comprised of a 3DP silicon nanowires array (3DP-SiNWA), decorated with silver nano-dendrites (AgNDs) atop. The 3DP-SiNWA is fabricated by a facile photolithographic process and low-cost metal assisted chemical etching (MaCE) process. Then, the AgNDs are decorated onto 3DP-SiNWA by a wet chemical reduction process, obtaining 3DP-AgNDs@SiNWA multifunctional substrates. With various patterns designed on the substrates, the signal intensity could be maximized by the excellent confinement and concentrated effects of patterns. By using this 3DP-AgNDs@SiNWA substrate to scrutinize the mixture of two visible dyes, the individual target could be recognized and further boosted the Raman signal of target 15.42 times comparing to the un-patterned AgNDs@SiNWA substrate. Therefore, such a three-dimensional patterned multifunctional substrate empowers rapid mixture screening, and can be readily employed in practical applications for biochemical assays, food safety and other fields.

  15. Numerical and experimental flow analysis in centifluidic systems for rapid allergy screening tests

    Directory of Open Access Journals (Sweden)

    Dethloff Manuel

    2015-09-01

    Full Text Available For the development of the automated processing of a membrane-based rapid allergy test, the flow characteristics in one part of the test, the reagents module, are analysed. This module consists of a multichannel system with several inputs and one output. A return flow from one input channel into another should be avoided. A valveless module with pointed channels at an angle of 12° is analysed with numerical and experimental methods with regard to the flow characteristics.

  16. Evaluation of seven rapid tests for syphilis available in Brazil using defibrinated plasma panels.

    Science.gov (United States)

    Bazzo, Maria Luiza; da Motta, Leonardo Rapone; Rudolf-Oliveira, Renata Cristina Messores; Bigolin, Alisson; Golfetto, Lisléia; Mesquita, Fábio; Benzaken, Adele Schwartz; Gaspar, Pamela Cristina; Pires, Ana Flavia Nacif P Coelho; Ferreira Júnior, Orlando da Costa; Franchini, Miriam

    2017-12-01

    In 2012, the WHO estimated that 6 million new cases of syphilis per year would occur worldwide, including 937 000 in Brazil. Early diagnosis and treatment of syphilis are essential to reduce morbidity and prevent transmission. The availability of rapid tests (RTs) for this diagnosis means that testing can be performed more quickly, as a point-of-care test, even in non-laboratory environments and requires only simple technical training to antibodies detection. The objective of this study was to evaluate the performance and operational aspects of seven commercially available RTs for syphilis in Brazil. Seven rapid treponemal tests were evaluated for sensitivity, specificity, accuracy and Kappa value, according to a panel composed of 493 members. The operational performance of the assay was also determined for these tests. The seven RTs showed sensitivity ranging from 94.5% to 100% when compared with the reference tests and specificity of between 91.5% and 100%. All the RTs evaluated presented good operational performance, and only one failed to present the minimum specificity as defined by Brazil's Ministry of Health. All the tests presented good operational performance, and the professionals who performed them considered them to be easy to use and interpret. This evaluation is important for making informed choices of tests to be used in the Brazilian Unified Health System. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  17. Biochemical evaluation of Gmelina arborea fruit meal as a swine ...

    African Journals Online (AJOL)

    Dr. J. T. Ekanem

    Division of Nutritional Biochemistry, Department of Animal Production,. University of Ilorin ... certain biochemical parameters including blood enzyme profile of wean pigs. 16-piglets ..... 1992) who reported similar results in guinea fowls fed test ...

  18. Design and Fabrication of Piezoresistive Based Encapsulated Poly-Si Cantilevers for Bio/chemical Sensing

    Science.gov (United States)

    Krishna, N. P. Vamsi; Murthy, T. R. Srinivasa; Reddy, K. Jayaprakash; Sangeeth, K.; Hegde, G. M.

    Cantilever-based sensing is a growing research field not only within micro regime but also in nano technology. The technology offers a method for rapid, on-line and in-situ monitoring of specific bio/chemical substances by detecting the nanomechanical responses of a cantilever sensor. Cantilever with piezoresistive based detection scheme is more attractive because of its electronics compatibility. Majority of commercially available micromachined piezoresistive sensors are bulk micromachined devices and are fabricated using single crystal silicon wafers. As substrate properties are not important in surface micromachining, the expensive silicon wafers can be replaced by cheaper substrates, such as poly-silicon, glass or plastic. Here we have designed SU-8 based bio/chemical compatible micro electro mechanical device that includes an encapsulated polysilicon piezoresistor for bio/chemical sensing. In this paper we report the design, fabrication and analysis of the encapsulated poly-Si cantilevers. Design and theoretical analysis are carried out using Finite Element Analysis software. For fabrication of poly-silicon piezoresistive cantilevers we followed the surface micromachining process steps. Preliminary characterization of the cantilevers is presented.

  19. A MULTILAYER BIOCHEMICAL DRY DEPOSITION MODEL 2. MODEL EVALUATION

    Science.gov (United States)

    The multilayer biochemical dry deposition model (MLBC) described in the accompanying paper was tested against half-hourly eddy correlation data from six field sites under a wide range of climate conditions with various plant types. Modeled CO2, O3, SO2<...

  20. Rapidity correlations test stochastic hydrodynamics

    International Nuclear Information System (INIS)

    Zin, C; Gavin, S; Moschelli, G

    2017-01-01

    We show that measurements of the rapidity dependence of transverse momentum correlations can be used to determine the characteristic time τ π that dictates the rate of isotropization of the stress energy tensor, as well as the shear viscosity ν = η/sT . We formulate methods for computing these correlations using second order dissipative hydrodynamics with noise. Current data are consistent with τ π /ν ∼ 10 but targeted measurements can improve this precision. (paper)

  1. Corrosion of metals in wood : comparing the results of a rapid test method with long-term exposure tests across six wood treatments

    Science.gov (United States)

    Samuel L. Zelinka; Donald S. Stone

    2011-01-01

    This paper compares two methods of measuring the corrosion of steel and galvanized steel in wood: a long-term exposure test in solid wood and a rapid test method where fasteners are electrochemically polarized in extracts of wood treated with six different treatments. For traditional wood preservatives, the electrochemical extract method correlates with solid wood...

  2. Thrombin-Accelerated Quick Clotting Serum Tubes: An Evaluation with 22 Common Biochemical Analytes

    Directory of Open Access Journals (Sweden)

    Wai-Yoong Ng

    2013-01-01

    Full Text Available Clot activator serum tubes have significantly improved turnaround times for result reporting compared to plain tubes. With increasing workload and service performance expectations confronting clinical laboratories with high-volume testing and with particular emphasis on critical analytes, attention has focussed on preanalytical variables that can be improved. We carried out a field study on the test performance of BD vacutainer rapid serum tubes (RSTs compared to current institutional issued BD vacutainer serum separator tubes (SSTs in its test result comparability, clotting time, and stability on serum storage. Data from the study population (n=160 of patients attending outpatient clinics and healthy subjects showed that results for renal, liver, lipids, cardiac, thyroid, and prostate biochemical markers were comparable between RSTs and SSTs. Clotting times of the RSTs were verified to be quick with a median time of 2.05 min. Analyte stability on serum storage at 4°C showed no statistically significant deterioration except for bicarbonate, electrolytes, and albumin over a period of 4 days. In conclusion, RSTs offered savings in the time required for the clotting process of serum specimens. This should translate to further trimming of the whole process from blood collection to result reporting without too much sacrifice on test accuracy and performance compared to the current widely used SSTs in most clinical laboratories.

  3. Recent Ground Hold and Rapid Depressurization Testing of Multilayer Systems

    Science.gov (United States)

    Johnson, Wesley L.

    2014-01-01

    In the development of flight insulation systems for large cryogenic orbital storage (spray on foam and multilayer insulation), testing need include all environments that are experienced during flight. While large efforts have been expended on studying, bounding, and modeling the orbital performance of the insulation systems, little effort has been expended on the ground hold and ascent phases of a mission. Historical cryogenic in-space systems that have flown have been able to ignore these phases of flight due to the insulation system being within a vacuum jacket. In the development phase of the Nuclear Mars Vehicle and the Shuttle Nuclear Vehicle, several insulation systems were evaluated for the full mission cycle. Since that time there had been minimal work on these phases of flight until the Constellation program began investigating cryogenic service modules and long duration upper stages. With the inception of the Cryogenic Propellant Storage and Transfer Technology Demonstration Mission, a specific need was seen for the data and as such, several tests were added to the Cryogenic Boil-off Reduction System liquid hydrogen test matrix to provide more data on a insulation system. Testing was attempted with both gaseous nitrogen (GN2) and gaseous helium (GHe) backfills. The initial tests with nitrogen backfill were not successfully completed due to nitrogen liquefaction and solidification preventing the rapid pumpdown of the vacuum chamber. Subsequent helium backfill tests were successful and showed minimal degradation. The results are compared to the historical data.

  4. Evaluation of three commercial rapid tests for detecting antibodies to human immunodeficiency virus.

    Science.gov (United States)

    Ng, K P; Saw, T L; Baki, A; Kamarudin, R

    2003-08-01

    Determine HIV-1/2, Chembio HIV-1/2 STAT-PAK and PenTest are simple/rapid tests for the detection of antibodies to HIV-1 and HIV-2 in human whole blood, serum and plasma samples. The assay is one step and the result is read visually within 15 minutes. Using 92 known HIV-1 reactive sera and 108 known HIV-1 negative sera, the 3 HIV tests correctly identified all the known HIV-1 reactive and negative samples. The results indicated that Determine HIV-1/2, Chembio HIV-1/2 STAT-PAK and PenTest HIV are as sensitive and specific (100% concordance) as Microparticle Enzyme Immunoassay. The data indicated that these 3 HIV tests are effective testing systems for diagnosis of HIV infection in a situation when the conventional Enzyme Immunoassay is not suitable.

  5. Implementation of broad screening with Ebola rapid diagnostic tests in Forécariah, Guinea

    Directory of Open Access Journals (Sweden)

    Frantz Jean Louis

    2017-03-01

    Full Text Available Background: Laboratory-enhanced surveillance is critical for rapidly detecting the potential re-emergence of Ebola virus disease. Rapid diagnostic tests (RDT for Ebola antigens could expand diagnostic capacity for Ebola virus disease. Objectives: The Guinean National Coordination for Ebola Response conducted a pilot implementation to determine the feasibility of broad screening of patients and corpses with the OraQuick® Ebola RDT. Methods: The implementation team developed protocols and trained healthcare workers to screen patients and corpses in Forécariah prefecture, Guinea, from 15 October to 30 November 2015. Data collected included number of consultations, number of fevers reported or measured, number of tests performed for patients or corpses and results of confirmatory RT-PCR testing. Data on malaria RDT results were collected for comparison. Feedback from Ebola RDT users was collected informally during supervision visits and forums. Results: There were 3738 consultations at the 15 selected healthcare facilities; 74.6% of consultations were for febrile illness. Among 2787 eligible febrile patients, 2633 were tested for malaria and 1628 OraQuick® Ebola RDTs were performed. A total of 322 OraQuick® Ebola RDTs were conducted on corpses. All Ebola tests on eligible patients were negative. Conclusions: Access to Ebola testing was expanded by the implementation of RDTs in an emergency situation. Feedback from Ebola RDT users and lessons learned will contribute to improving quality for RDT expansion.

  6. Rapid identification of bacteria in positive blood culture broths by matrix-assisted laser desorption ionization-time of flight mass spectrometry.

    Science.gov (United States)

    Stevenson, Lindsay G; Drake, Steven K; Murray, Patrick R

    2010-02-01

    Matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry is a rapid, accurate method for identifying bacteria and fungi recovered on agar culture media. We report herein a method for the direct identification of bacteria in positive blood culture broths by MALDI-TOF mass spectrometry. A total of 212 positive cultures were examined, representing 32 genera and 60 species or groups. The identification of bacterial isolates by MALDI-TOF mass spectrometry was compared with biochemical testing, and discrepancies were resolved by gene sequencing. No identification (spectral score of blood culture broth. Of the bacteria with a spectral score of > or = 1.7, 162 (95.3%) of 170 isolates were correctly identified. All 8 isolates of Streptococcus mitis were misidentified as being Streptococcus pneumoniae isolates. This method provides a rapid, accurate, definitive identification of bacteria within 1 h of detection in positive blood cultures with the caveat that the identification of S. pneumoniae would have to be confirmed by an alternative test.

  7. Teste rápido para detecção da infecção pelo HIV-1 em gestantes Rapid test to detect HIV-1 infection among pregnant women

    Directory of Open Access Journals (Sweden)

    Geraldo Duarte

    2001-03-01

    Full Text Available Objetivos: avaliar os resultados do teste de diagnóstico rápido da infecção pelo HIV-1 disponibilizado pelo Ministério da Saúde, para identificação de gestantes contaminadas por este vírus. Métodos: avaliação prospectiva de 443 gestantes sem teste sorológico para HIV no pré-natal, atendidas no Departamento de Ginecologia e Obstetrícia da Faculdade de Medicina de Ribeirão Preto-Universidade de São Paulo (HCFMRP-USP, entre fevereiro e junho de 2000. As amostras destas pacientes foram submetidas ao teste rápido imunocromatográfico, sendo comparadas com ELISA e confirmadas pela aglutinação. Resultados: dentre as 443 gestantes submetidas ao teste rápido (20,1% dos partos no período, 16 apresentaram resultados positivos (3,6%. Nenhuma amostra negativa pelo teste rápido foi positiva pelo ELISA. Entretanto, das 16 amostras positivas pelo teste rápido, duas foram negativas pelos testes confirmatórios. Logo, a sensibilidade do teste rápido foi de 100,0%, especificidade 99,5%, valor preditivo positivo 87,5% e valor preditivo negativo 100,0%. Conclusões: os resultados obtidos na avaliação do teste para o diagnóstico rápido da infecção pelo HIV-1 em gestantes revelaram sensibilidade, especificidade e valores preditivos que o credenciam como recurso extremamente importante na indicação de medidas que reduzem a transmissão perinatal desse vírus.Purpose: to evaluate the results of a rapid diagnostic test for HIV-1 infection made available by the Health Ministry for the identification of pregnant women contaminated by this virus. Methods: we evaluated prospectively 443 pregnant women with no prenatal serologic anti-HIV test seen at the Department of Gynecology and Obstetrics of the Faculty of Medicine of Ribeirão Preto, University of São Paulo, from February to June, 2000. Samples from these patients were submitted to the rapid immunochromatographic test, which was compared with ELISA and submitted to a confirmatory

  8. Chapter A7. Section 7.0. Five-Day Biochemical Oxygen Demand

    Science.gov (United States)

    Delzer, Gregory C.; McKenzie, Stuart W.

    1999-01-01

    The presence of a sufficient concentration of dissolved oxygen is critical to maintaining the aquatic life and aesthetic quality of streams and lakes. Determinng how organic matter affects the concentration of dissolved oxygen (DO) in a stream or lake is integral to water-quality management. The decay of organic matter in water is measured as biochemical or chemical oxygen demand. This report describes the field protocols used by U.S. Geological Survey (USGS) personnel to determine the five-day test for biochemical oxygen demand.

  9. Rapid detox: understanding new treatment approaches for the addicted patient.

    Science.gov (United States)

    McCabe, S

    2000-01-01

    Despite substantive advances in understanding of genetic and biochemical basis of substance abuse and addiction in the last decade, little information has been translated into alternative treatment models for the addicted patient. Rapid detox, an alternative form of detox treatment, is gaining in both acceptance and popularity. To increase readers' understanding of the neurobiology of addiction and the mode of action of new detox approaches for patients addicted to opiate drugs. A review of the current literature pertaining to rapid detox. Rapid detox is a viable alternative for selected patients attempting to detox from opiate agents of abuse. Increasing knowledge of new treatment approaches allows nurses working to assist addicted patients in planning and receiving treatment based on new awareness of the neurobiology of addiction.

  10. Kato-Katz and Lumbreras rapid sedimentation test to evaluate helminth prevalence in the setting of a school-based deworming program

    OpenAIRE

    Lopez, Martha; Morales, Maria Luisa; Konana, Monisha; Hoyer, Paige; Pineda-Reyes, Roberto; White, Arthur Clinton; Garcia, Hector Hugo; Lescano, Andres Guillermo; Gotuzzo, Eduardo; Cabada, Miguel Mauricio

    2016-01-01

    The sensitivity of the Kato-Katz test is suboptimal for the evaluation of intestinal helminth prevalence. Moreover, during mass deworming, as helminth egg burden decreases, the sensitivity is likely to decrease. The Lumbreras rapid sedimentation (Lumbreras) is a low-cost non-quantitative test, but may provide useful information in low burden areas. We compared the prevalence of intestinal helminth infections assessed by the Kato-Katz and the Lumbreras rapid sedimentation test on 3 stool speci...

  11. Integrated Rapid-Diagnostic-Test Reader Platform on a Cellphone

    Science.gov (United States)

    Mudanyali, Onur; Dimitrov, Stoyan; Sikora, Uzair; Padmanabhan, Swati; Navruz, Isa; Ozcan, Aydogan

    2012-01-01

    We demonstrate a cellphone based Rapid-Diagnostic-Test (RDT) reader platform that can work with various lateral flow immuno-chromatographic assays and similar tests to sense the presence of a target analyte in a sample. This compact and cost-effective digital RDT reader, weighing only ~65 grams, mechanically attaches to the existing camera unit of a cellphone, where various types of RDTs can be inserted to be imaged in reflection or transmission modes under light-emitting-diode (LED) based illumination. Captured raw images of these tests are then digitally processed (within less than 0.2 sec/image) through a smart application running on the cellphone for validation of the RDT as well as for automated reading of its diagnostic result. The same smart application running on the cellphone then transmits the resulting data, together with the RDT images and other related information (e.g., demographic data) to a central server, which presents the diagnostic results on a world-map through geo-tagging. This dynamic spatio-temporal map of various RDT results can then be viewed and shared using internet browsers or through the same cellphone application. We tested this platform using malaria, tuberculosis (TB) as well as HIV RDTs by installing it on both Android based smart-phones as well as an iPhone. Providing real-time spatio-temporal statistics for the prevalence of various infectious diseases, this smart RDT reader platform running on cellphones might assist health-care professionals and policy makers to track emerging epidemics worldwide and help epidemic preparedness. PMID:22596243

  12. The impact of atrazine on several biochemical properties of chernozem soil

    Directory of Open Access Journals (Sweden)

    LJ. RADIVOJEVIC

    2008-10-01

    Full Text Available The impact of the pesticide atrazine on biochemical processes in soil was investigated. Atrazine loadings of 8.0, 40.0 and 80.0 mg/kg soil were laboratory tested in an experiment set up on a clay loam soil. Dehydrogenase activity, change in biomass carbon, soil respiration and metabolic coefficient were examined. The samples were collected for analysis 1, 7, 14, 21, 30 and 60 days after atrazine application. The acquired data indicated that the effect of atrazine on the biochemical activity of the soil depended on its application rate and duration of activity, and the effect was either stimulating or inhibiting. However, the detected changes were found to be transient, indicating that there is no real risk of the compound disrupting the balance of biochemical processes in soil.

  13. Performance of rapid tests and algorithms for HIV screening in Abidjan, Ivory Coast.

    Science.gov (United States)

    Loukou, Y G; Cabran, M A; Yessé, Zinzendorf Nanga; Adouko, B M O; Lathro, S J; Agbessi-Kouassi, K B T

    2014-01-01

    Seven rapid diagnosis tests (RDTs) of HIV were evaluated by a panel group who collected serum samples from patients in Abidjan (HIV-1 = 203, HIV-2 = 25, HIV-dual = 25, HIV = 305). Kit performances were recorded after the reference techniques (enzyme-linked immunosorbent assay). The following RDTs showed a sensitivity of 100% and a specificity higher than 99%: Determine, Oraquick, SD Bioline, BCP, and Stat-Pak. These kits were used to establish infection screening strategies. The combination with 2 or 3 of these tests in series or parallel algorithms showed that series combinations with 2 tests (Oraquick and Bioline) and 3 tests (Determine, BCP, and Stat-Pak) gave the best performances (sensitivity, specificity, positive predictive value, and negative predictive value of 100%). However, the combination with 2 tests appeared to be more onerous than the combination with 3 tests. The combination with Determine, BCP, and Stat-Pak tests serving as a tiebreaker could be an alternative to the HIV/AIDS serological screening in Abidjan.

  14. Preliminary Results of a Multicentre Study of the UBC Rapid Test for Detection of Urinary Bladder Cancer.

    Science.gov (United States)

    Ecke, Thorsten H; Arndt, Christian; Stephan, Carsten; Hallmann, Steffen; Lux, Oliver; Otto, Thomas; Ruttloff, Jürgen; Gerullis, Holger

    2015-05-01

    UBC Rapid is a test detecting fragments of cytokeratins 8 and 18 in urine. These are cytokeratins frequently overexpressed in tumor cells. We present the first results of a multi-centre study using UBC Rapid in patients with bladder cancer and healthy controls. Clinical urine samples from 92 patients with tumors of the urinary bladder (45 low-grade and 47 high-grade tumors) and from 33 healthy controls were used. Urine samples were analyzed by the UBC Rapid point-of-care (POC) system and evaluated both visually and quantitatively using a concile Omega 100 POC reader. For visual evaluation, different thresholds of band intensity for considering a test as positive were applied. Sensitivities and specificities were calculated by contingency analyses. We found that pathological concentrations by UBC Rapid are detectable in urine of patients with bladder cancer. The calculated diagnostic sensitivity of UBC Rapid in urine was 68.1% for high-grade, but only 46.2% for low-grade tumors. The specificity was 90.9%. The area under the curve (AUC) after receiver-operated curve (ROC) analysis was 0.733. Pathological levels of UBC Rapid in urine are higher in patients with bladder cancer in comparison to the control group (pbladder cancer and controls. Further studies with a greater number of patients will show how valuable these results are. Copyright© 2015 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  15. Provider-related barriers to rapid HIV testing in U.S. urban non-profit community clinics, community-based organizations (CBOs) and hospitals.

    Science.gov (United States)

    Bogart, Laura M; Howerton, Devery; Lange, James; Setodji, Claude Messan; Becker, Kirsten; Klein, David J; Asch, Steven M

    2010-06-01

    We examined provider-reported barriers to rapid HIV testing in U.S. urban non-profit community clinics, community-based organizations (CBOs), and hospitals. 12 primary metropolitan statistical areas (PMSAs; three per region) were sampled randomly, with sampling weights proportional to AIDS case reports. Across PMSAs, all 671 hospitals and a random sample of 738 clinics/CBOs were telephoned for a survey on rapid HIV test availability. Of the 671 hospitals, 172 hospitals were randomly selected for barriers questions, for which 158 laboratory and 136 department staff were eligible and interviewed in 2005. Of the 738 clinics/CBOs, 276 were randomly selected for barriers questions, 206 were reached, and 118 were eligible and interviewed in 2005-2006. In multivariate models, barriers regarding translation of administrative/quality assurance policies into practice were significantly associated with rapid HIV testing availability. For greater rapid testing diffusion, policies are needed to reduce administrative barriers and provide quality assurance training to non-laboratory staff.

  16. Blood gas and serum biochemical RIs for healthy newborn Murrah buffaloes (Bubalus bubalis).

    Science.gov (United States)

    Santana, André M; Silva, Daniela G; Clemente, Virna; Pizauro, Lucas J L; Bernardes, Priscila A; Santana, Clarissa H; Eckersall, Peter D; Fagliari, José J

    2018-03-01

    There is a lack of published work on RIs for newborn buffaloes. Establishing blood gas and serum biochemical RIs for newborn buffaloes is important for monitoring health. This study establishes blood gas and serum biochemical RIs of newborn buffaloes. Twenty-eight newborn buffaloes, 10-30 days old, were selected. Thirty blood biochemical variables were analyzed. The Anderson-Darling test was used to assess the normality of the distribution. The Dixon test and the Tukey test were used to identify outliers. The RI and 90% CI were determined using standard and robust methods and the Box-Cox transformation. A total of 30 RIs for healthy buffalo calves have been reported in this study. RIs for blood gas variables were reported for pH, partial pressure of oxygen (pO 2 ), partial pressure of carbon dioxide (pCO 2 ), saturation of O 2 (SO 2 ), bicarbonate (cHCO 3 - ), base excess (BE), total carbon dioxide (ctCO 2 ), and anion gap (AG). RIs for serum biochemical variables were reported for glucose (GLU), direct bilirubin (DB), total bilirubin (TB), AST, ALP, GGT, CK, LDH, creatinine (CREA), urea, cholesterol (CHOL), triglycerides (TG), Ca, P, Mg, Na, K, iCa, Cl, iron, total protein (TP), and albumin (ALB). This is the first reported study covering complete serum chemistry and blood gas RIs for healthy 1-month-old Murrah buffaloes. © 2018 American Society for Veterinary Clinical Pathology.

  17. Rapid testing and identification of actuator using dSPACE real-time emulator

    Science.gov (United States)

    Xie, Daocheng; Wang, Zhongwei; Zeng, Qinghua

    2011-10-01

    To solve the problem of model identification of actuator in control system design of aerocraft, testing system based on dSPACE emulator is established, sending testing signal and receiving feedback voltage are realized using dSPACE interactive cards, communication between signal generating equipment and feedback voltage acquisition equipment is synchronized. This paper introduces the hardware architecture and key technologies of the simulation system. Constructing, downloading and calculating of the testing model is finished using dSPACE emulator, D/A transfer of testing signal is realized using DS2103 card, DS2002 card transfer the feedback voltage to digital value. Filtering module is added to the signal acquisition, for reduction of noise interference in the A/D channel. Precision of time and voltage is improved by setting acquisition period 1ms. The data gathered is recorded and displayed with Controldesk tools. The response of four actuators under different frequency are tested, frequency-domain analysis is done using least square method, the model of actuator is identified, simulation data fits well with real response of the actuator. The testing system created with dSPACE emulator satisfies the rapid testing and identification of actuator.

  18. Improving the screening of blood donors with syphilis rapid diagnostic test (RDT) and rapid plasma reagin (RPR) in low- and middle-income countries (LMIC).

    Science.gov (United States)

    Sarkodie, F; Hassall, O; Owusu-Dabo, E; Owusu-Ofori, S; Bates, I; Bygbjerg, I C; Owusu-Ofori, A; Harritshøj, L H; Ullum, H

    2017-02-01

    Syphilis testing conventionally relies on a combination of non-treponemal and treponemal tests. The primary objective of this study was to describe the positive predictive value (PPV) of a screening algorithm in a combination of a treponemal rapid diagnostic test (RDT) and rapid plasma reagin (RPR) test at Komfo Anokye Teaching Hospital (KATH), Ghana. From February 2014 to January 2015, 5 mL of venous blood samples were taken from 16 016 blood donors and tested with a treponemal RDT; 5 mL of venous blood was taken from 526 consenting initial syphilis sero-reactive blood donors. These RDT reactive samples were confirmed with an algorithm, applying the Vitros ® /Abbott-Architect ® algorithm as gold standard. A total of 478 of 526 RDT reactive donors were confirmed positive for syphilis, making a PPV of 90·9%. Of the 172 (32·7%) donors who were also RPR positive, 167 were confirmed, resulting in a PPV of 97·1%. The PPV of the combined RDT and RPR (suspected active syphilis) testing algorithm was highest among donors at an enhanced risk of syphilis, family/replacement donors (99·9%), and among voluntary donors above 25 years (98·6%). Screening of blood donors by combining syphilis RDT and RPR with relatively good PPV may provide a reasonable technology for LMIC that has a limited capacity for testing and can contribute to the improvement of blood safety with a minimal loss of donors. © 2016 British Blood Transfusion Society.

  19. Accuracy and user-acceptability of HIV self-testing using an oral fluid-based HIV rapid test.

    Directory of Open Access Journals (Sweden)

    Oon Tek Ng

    Full Text Available BACKGROUND: The United States FDA approved an over-the-counter HIV self-test, to facilitate increased HIV testing and earlier linkage to care. We assessed the accuracy of self-testing by untrained participants compared to healthcare worker (HCW testing, participants' ability to interpret sample results and user-acceptability of self-tests in Singapore. METHODOLOGY/PRINCIPAL FINDINGS: A cross-sectional study, involving 200 known HIV-positive patients and 794 unknown HIV status at-risk participants was conducted. Participants (all without prior self-test experience performed self-testing guided solely by visual instructions, followed by HCW testing, both using the OraQuick ADVANCE Rapid HIV 1/2 Antibody Test, with both results interpreted by the HCW. To assess ability to interpret results, participants were provided 3 sample results (positive, negative, and invalid to interpret. Of 192 participants who tested positive on HCW testing, self-testing was positive in 186 (96.9%, negative in 5 (2.6%, and invalid in 1 (0.5%. Of 794 participants who tested negative on HCW testing, self-testing was negative in 791 (99.6%, positive in 1 (0.1%, and invalid in 2 (0.3%. Excluding invalid tests, self-testing had sensitivity of 97.4% (95% CI 95.1% to 99.7% and specificity of 99.9% (95% CI: 99.6% to 100%. When interpreting results, 96%, 93.1% and 95.2% correctly read the positive, negative and invalid respectively. There were no significant demographic predictors for false negative self-testing or wrongly interpreting positive or invalid sample results as negative. Eighty-seven percent would purchase the kit over-the-counter; 89% preferred to take HIV tests in private. 72.5% and 74.9% felt the need for pre- and post-test counseling respectively. Only 28% would pay at least USD15 for the test. CONCLUSIONS/SIGNIFICANCE: Self-testing was associated with high specificity, and a small but significant number of false negatives. Incorrectly identifying model results as

  20. Study on the alteration of bubaline blood biochemical composition ...

    African Journals Online (AJOL)

    Bubaline blood biochemistry as affected by slaughter was the agenda for this work. Blood samples were collected from 30 buffaloes from abattoirs before and at slaughter. After biochemical and statistical analysis (mean was compared with t-test), it was observed that the albumin, lactate dehydrogenase and creatine kinase ...

  1. Research advance in rapid detection of foodborne Staphylococcus aureus

    OpenAIRE

    Xihong Zhao; Caijiao Wei; Junliang Zhong; Shiwei Jin

    2016-01-01

    Staphylococcus aureus is a gram-positive, coccus-shaped facultative anaerobe and a member of the Staphylococcaceae family. In recent years, alimentary toxicosis caused by S. aureus is a very serious problem worldwide, which constitutes a great threat to public health. In this review, we tried to summarize the conventional methods and newly developed rapid detection techniques of S. aureus (traditional detection method, biochemical detection, immunology method, molecular biology, and biosensor...

  2. Clients of sex workers in Switzerland: it makes sense to counsel and propose rapid test for HIV on the street, a preliminary report.

    Science.gov (United States)

    Diserens, Esther-Amélie; Bodenmann, Patrick; N'Garambe, Chantal; Ansermet-Pagot, Anne; Vannotti, Marco; Masserey, Eric; Cavassini, Matthias

    2010-03-19

    Clients of street sex workers may be at higher risk for HIV infection than the general population. Furthermore, there is a lack of knowledge regarding HIV testing of clients of sex workers in developed countries. This pilot study assessed the feasibility and acceptance of rapid HIV testing by the clients of street-based sex workers in Lausanne, Switzerland. For 5 evenings, clients in cars were stopped by trained field staff for face-to-face interviews focusing on sex-related HIV risk behaviors and HIV testing history. The clients were then offered a free anonymous rapid HIV test in a bus parked nearby. Rapid HIV testing and counselling were performed by experienced nurse practitioners. Clients with reactive tests were offered confirmatory testing, medical evaluation, and care in our HIV clinic. We intercepted 144 men, 112 (77.8%) agreed to be interviewed. Among them, 50 (46.6%) had never been tested for HIV. A total of 31 (27.7%) rapid HIV tests were performed, 16 (51.6%) in clients who had not previously been tested. None were reactive. Initially, 19 (16.9%) additional clients agreed to HIV testing but later declined due to the 40-minute queue for testing. This pilot study showed that rapid HIV testing in the red light district of Lausanne was feasible, and that the clients of sex workers accepted testing at an unexpectedly high rate. This setting seems particularly appropriate for targeted HIV screening, since more than 40% of the clients had not previously been tested for HIV even though they engaged in sex-related HIV risk behaviour.

  3. Safety of a rapid diagnostic protocol with accelerated stress testing.

    Science.gov (United States)

    Soremekun, Olan A; Hamedani, Azita; Shofer, Frances S; O'Conor, Katie J; Svenson, James; Hollander, Judd E

    2014-02-01

    Most patients at low to intermediate risk for an acute coronary syndrome (ACS) receive a 12- to 24-hour "rule out." Recently, trials have found that a coronary computed tomographic angiography-based strategy is more efficient. If stress testing were performed within the same time frame as coronary computed tomographic angiography, the 2 strategies would be more similar. We tested the hypothesis that stress testing can safely be performed within several hours of presentation. We performed a retrospective cohort study of patients presenting to a university hospital from January 1, 2009, to December 31, 2011, with potential ACS. Patients placed in a clinical pathway that performed stress testing after 2 negative troponin values 2 hours apart were included. We excluded patients with ST-elevation myocardial infarction or with an elevated initial troponin. The main outcome was safety of immediate stress testing defined as the absence of death or acute myocardial infarction (defined as elevated troponin within 24 hours after the test). A total of 856 patients who presented with potential ACS were enrolled in the clinical pathway and included in this study. Patients had a median age of 55.0 (interquartile range, 48-62) years. Chest pain was the chief concern in 86%, and pain was present on arrival in 73% of the patients. There were no complications observed during the stress test. There were 0 deaths (95% confidence interval, 0%-0.46%) and 4 acute myocardial infarctions within 24 hours (0.5%; 95% confidence interval, 0.14%-1.27%). The peak troponins were small (0.06, 0.07, 0.07, and 0.19 ng/mL). Patients who present to the ED with potential ACS can safely undergo a rapid diagnostic protocol with stress testing. © 2013.

  4. A comparative study of rapid test and routine methods for the measurement of cardiac markers in patients with suspected acute myocardial infarction

    Directory of Open Access Journals (Sweden)

    gholamreza Shahsavari

    2014-06-01

    Conclusion: The present results showed that the rapid cTnI test is very specific but not sensitive for AMI diagnosis while rapid CK-MB test is neither sensitive nor specific for AMI dignosis in patients with acute chest pain.

  5. Non-reactive HIV-1 Rapid Tests after Sustained Viral Suppression Following Antiretroviral Therapy Initiation During Primary Infection.

    Science.gov (United States)

    Stefic, Karl; Novelli, Sophie; Mahjoub, Nadia; Seng, Remonie; Molina, Jean-Michel; Cheneau, Christine; Barin, Francis; Chaix, Marie-Laure; Meyer, Laurence; Delaugerre, Constance

    2018-03-02

    We assessed the impact of early antiretroviral treatment (ART) on HIV antibody detection by rapid tests in 44 individuals after several years of successful ART. HIV self-tests and point-of-care tests were negative in respectively 30% and 7-9% of cases. These data reinforce the message that patients should never be retested after entering HIV care.

  6. Can the Bruckner test be used as a rapid screening test to detect significant refractive errors in children?

    Directory of Open Access Journals (Sweden)

    Kothari Mihir

    2007-01-01

    Full Text Available Purpose: To assess the suitability of Brückner test as a screening test to detect significant refractive errors in children. Materials and Methods: A pediatric ophthalmologist prospectively observed the size and location of pupillary crescent on Brückner test as hyperopic, myopic or astigmatic. This was compared with the cycloplegic refraction. Detailed ophthalmic examination was done for all. Sensitivity, specificity, positive predictive value and negative predictive value of Brückner test were determined for the defined cutoff levels of ametropia. Results: Ninety-six subjects were examined. Mean age was 8.6 years (range 1 to 16 years. Brückner test could be completed for all; the time taken to complete this test was 10 seconds per subject. The ophthalmologist identified 131 eyes as ametropic, 61 as emmetropic. The Brückner test had sensitivity 91%, specificity 72.8%, positive predictive value 85.5% and negative predictive value 83.6%. Of 10 false negatives four had compound hypermetropic astigmatism and three had myopia. Conclusions: Brückner test can be used to rapidly screen the children for significant refractive errors. The potential benefits from such use may be maximized if programs use the test with lower crescent measurement cutoffs, a crescent measurement ruler and a distance fixation target.

  7. Identification of biochemical features of defective Coffea arabica L. beans.

    Science.gov (United States)

    Casas, María I; Vaughan, Michael J; Bonello, Pierluigi; McSpadden Gardener, Brian; Grotewold, Erich; Alonso, Ana P

    2017-05-01

    Coffee organoleptic properties are based in part on the quality and chemical composition of coffee beans. The presence of defective beans during processing and roasting contribute to off flavors and reduce overall cup quality. A multipronged approach was undertaken to identify specific biochemical markers for defective beans. To this end, beans were split into defective and non-defective fractions and biochemically profiled in both green and roasted states. A set of 17 compounds in green beans, including organic acids, amino acids and reducing sugars; and 35 compounds in roasted beans, dominated by volatile compounds, organic acids, sugars and sugar alcohols, were sufficient to separate the defective and non-defective fractions. Unsorted coffee was examined for the presence of the biochemical markers to test their utility in detecting defective beans. Although the green coffee marker compounds were found in all fractions, three of the roasted coffee marker compounds (1-methylpyrrole, 5-methyl- 2-furfurylfuran, and 2-methylfuran) were uniquely present in defective fractions. Published by Elsevier Ltd.

  8. Dynamic changes in biochemical markers of renal function with ...

    African Journals Online (AJOL)

    Thyroid dysfunction is known to cause significant changes in glomerular filtration rate. The present cross-sectional study was performed to evaluate the changes in biochemical markers of renal function in hypothyroid subjects before and after treatment. Thyroid function tests (T3, T4 and TSH levels) were assayed in 385 ...

  9. Impact of parathion exposure on some biochemical parameters in ...

    African Journals Online (AJOL)

    Nagat Aly

    2014-09-16

    Sep 16, 2014 ... developing field aims to reveal environmental threats before obvious toxic effects such as ... followed by the Student–Newman–Keuls test to determine sig- nificance between ..... open-field activity in chicks. Toxicol Lett 2007 ... ical and serum biochemical changes in mice and protective effect · of vitamin C. J ...

  10. Rapid susceptibility testing and microcolony analysis of Candida spp. cultured and imaged on porous aluminum oxide.

    Directory of Open Access Journals (Sweden)

    Colin J Ingham

    Full Text Available BACKGROUND: Acquired resistance to antifungal agents now supports the introduction of susceptibility testing for species-drug combinations for which this was previously thought unnecessary. For pathogenic yeasts, conventional phenotypic testing needs at least 24 h. Culture on a porous aluminum oxide (PAO support combined with microscopy offers a route to more rapid results. METHODS: Microcolonies of Candida species grown on PAO were stained with the fluorogenic dyes Fun-1 and Calcofluor White and then imaged by fluorescence microscopy. Images were captured by a charge-coupled device camera and processed by publicly available software. By this method, the growth of yeasts could be detected and quantified within 2 h. Microcolony imaging was then used to assess the susceptibility of the yeasts to amphotericin B, anidulafungin and caspofungin (3.5 h culture, and voriconazole and itraconazole (7 h culture. SIGNIFICANCE: Overall, the results showed good agreement with EUCAST (86.5% agreement; n = 170 and E-test (85.9% agreement; n = 170. The closest agreement to standard tests was found when testing susceptibility to amphotericin B and echinocandins (88.2 to 91.2% and the least good for the triazoles (79.4 to 82.4%. Furthermore, large datasets on population variation could be rapidly obtained. An analysis of microcolonies revealed subtle effects of antimycotics on resistant strains and below the MIC of sensitive strains, particularly an increase in population heterogeneity and cell density-dependent effects of triazoles. Additionally, the method could be adapted to strain identification via germ tube extension. We suggest PAO culture is a rapid and versatile method that may be usefully adapted to clinical mycology and has research applications.

  11. Rapid bacterial antibiotic susceptibility test based on simple surface-enhanced Raman spectroscopic biomarkers

    Science.gov (United States)

    Liu, Chia-Ying; Han, Yin-Yi; Shih, Po-Han; Lian, Wei-Nan; Wang, Huai-Hsien; Lin, Chi-Hung; Hsueh, Po-Ren; Wang, Juen-Kai; Wang, Yuh-Lin

    2016-03-01

    Rapid bacterial antibiotic susceptibility test (AST) and minimum inhibitory concentration (MIC) measurement are important to help reduce the widespread misuse of antibiotics and alleviate the growing drug-resistance problem. We discovered that, when a susceptible strain of Staphylococcus aureus or Escherichia coli is exposed to an antibiotic, the intensity of specific biomarkers in its surface-enhanced Raman scattering (SERS) spectra drops evidently in two hours. The discovery has been exploited for rapid AST and MIC determination of methicillin-susceptible S. aureus and wild-type E. coli as well as clinical isolates. The results obtained by this SERS-AST method were consistent with that by the standard incubation-based method, indicating its high potential to supplement or replace existing time-consuming methods and help mitigate the challenge of drug resistance in clinical microbiology.

  12. Interpretation of electrocardiographic, echocardiographic and biochemical findings during different stages of Canine Visceral Leishmaniasis

    Directory of Open Access Journals (Sweden)

    Ural K

    2017-09-01

    Full Text Available Objective. The purpose of the present study was to test the hypothesis that cardiac alterations participate within different stages of CVL. Materials and methods. Twenty-eight dogs were diagnosed with CVL, were classified [based on clinical signs, rapid ELISA/IFAT, hematological and serum biochemical tests, urinary protein/creatinine ratio, ECG and ECHO]. as follows; group I (mild disease, group II (moderate disease, group III (severe disease, group IV (very severe disease and group V included healthy controls. Results. Ig G antibodies against leishmaniasis as tested by IFAT, were deemed 1/64 to 1/16000 among infected groups. There were statistical significance regarding mean values for WBC [among healthy control group (V. and other groups (p=0.049], RBC [among stage III-stage IV and other groups (p=0.001], Hb [between stage I and stage III-stage IV (p=0.008, HCT [between stage I and other groups (p = 0.001] MCHC [between stage I and stage II- stage IV (p=0.046], serum creatinine [(p=0.008 stage IV and stage I-II within group V], serum protein [(p=0.002 among stage IV and stage I-III- healthy control groups] and serum albumine [(p=0.004 among stage IV and stage I-II]. There was no alteration in CTnI concentrations,among groups. UPC analysis revealed statistical difference among control group and stage II to IV dogs (p=0.000. Moderate or severe ECG abnormalities were detected in 6/28 of diseased dogs. Regarding ECHO examination LA/ Ao value presented significant difference (p=0.003 among stage IV and other groups. Conclusions. It may be suggested that establishing Leishvet Working Group to those of dogs classified into stage I to IV, ECG [left atrial/ventricular enlargement, myocardial hypoxia] and ECHO [left atrial dilation, decrased/increased LVIDs, decrased/increased LVIDd, shortened FS and EF (systolic dysfunction] alterations must be taken into account along with hematological and serum biochemical analysis.

  13. Text-based phenotypic profiles incorporating biochemical phenotypes of inborn errors of metabolism improve phenomics-based diagnosis.

    Science.gov (United States)

    Lee, Jessica J Y; Gottlieb, Michael M; Lever, Jake; Jones, Steven J M; Blau, Nenad; van Karnebeek, Clara D M; Wasserman, Wyeth W

    2018-05-01

    Phenomics is the comprehensive study of phenotypes at every level of biology: from metabolites to organisms. With high throughput technologies increasing the scope of biological discoveries, the field of phenomics has been developing rapid and precise methods to collect, catalog, and analyze phenotypes. Such methods have allowed phenotypic data to be widely used in medical applications, from assisting clinical diagnoses to prioritizing genomic diagnoses. To channel the benefits of phenomics into the field of inborn errors of metabolism (IEM), we have recently launched IEMbase, an expert-curated knowledgebase of IEM and their disease-characterizing phenotypes. While our efforts with IEMbase have realized benefits, taking full advantage of phenomics requires a comprehensive curation of IEM phenotypes in core phenomics projects, which is dependent upon contributions from the IEM clinical and research community. Here, we assess the inclusion of IEM biochemical phenotypes in a core phenomics project, the Human Phenotype Ontology. We then demonstrate the utility of biochemical phenotypes using a text-based phenomics method to predict gene-disease relationships, showing that the prediction of IEM genes is significantly better using biochemical rather than clinical profiles. The findings herein provide a motivating goal for the IEM community to expand the computationally accessible descriptions of biochemical phenotypes associated with IEM in phenomics resources.

  14. Study on the chloride migration coefficient obtained following different Rapid Chloride Migration (RCM) test guidelines

    NARCIS (Netherlands)

    Spiesz, P.R.; Brouwers, H.J.H.; Uzoegbo, H.C.; Schmidt, W.

    2013-01-01

    This work presents the differences in the available Rapid Chloride Migration (RCM) test guidelines, and their influence on the values of the chloride migration coefficients DRCM, obtained following these guidelines. It is shown that the differences between the guidelines are significant and concern

  15. Assessing stakeholder perceptions of the acceptability and feasibility of national scale-up for a dual HIV/syphilis rapid diagnostic test in Malawi.

    Science.gov (United States)

    Maddox, Brandy L Peterson; Wright, Shauntā S; Namadingo, Hazel; Bowen, Virginia B; Chipungu, Geoffrey A; Kamb, Mary L

    2017-12-01

    The WHO recommends pregnant women receive both HIV and syphilis testing at their first antenatal care visit, as untreated maternal infections can lead to severe, adverse pregnancy outcomes. One strategy for increasing testing for both HIV and syphilis is the use of point-of-care (rapid) diagnostic tests that are simple, proven effective and inexpensive. In Malawi, pregnant women routinely receive HIV testing, but only 10% are tested for syphilis at their first antenatal care visit. This evaluation explores stakeholder perceptions of a novel, dual HIV/syphilis rapid diagnostic test and potential barriers to national scale-up of the dual test in Malawi. During June and July 2015, we conducted 15 semistructured interviews with 25 healthcare workers, laboratorians, Ministry of Health leaders and partner agency representatives working in prevention of mother-to-child transmission in Malawi. We asked stakeholders about the importance of a dual rapid diagnostic test, concerns using and procuring the dual test and recommendations for national expansion. Stakeholders viewed the test favourably, citing the importance of a dual rapid test in preventing missed opportunities for syphilis diagnosis and treatment, improving infant outcomes and increasing syphilis testing coverage. Primary technical concerns were about the additional procedural steps needed to perform the test, the possibility that testers may not adhere to required waiting times before interpreting results and difficulty reading and interpreting test results. Stakeholders thought national scale-up would require demonstration of cost-savings, uniform coordination, revisions to testing guidelines and algorithms, training of testers and a reliable supply chain. Stakeholders largely support implementation of a dual HIV/syphilis rapid diagnostic test as a feasible alternative to current antenatal testing. Scale-up will require addressing perceived barriers; negotiating changes to existing algorithms and guidelines

  16. Evaluation of PDA Technical Report No 33. Statistical Testing Recommendations for a Rapid Microbiological Method Case Study.

    Science.gov (United States)

    Murphy, Thomas; Schwedock, Julie; Nguyen, Kham; Mills, Anna; Jones, David

    2015-01-01

    New recommendations for the validation of rapid microbiological methods have been included in the revised Technical Report 33 release from the PDA. The changes include a more comprehensive review of the statistical methods to be used to analyze data obtained during validation. This case study applies those statistical methods to accuracy, precision, ruggedness, and equivalence data obtained using a rapid microbiological methods system being evaluated for water bioburden testing. Results presented demonstrate that the statistical methods described in the PDA Technical Report 33 chapter can all be successfully applied to the rapid microbiological method data sets and gave the same interpretation for equivalence to the standard method. The rapid microbiological method was in general able to pass the requirements of PDA Technical Report 33, though the study shows that there can be occasional outlying results and that caution should be used when applying statistical methods to low average colony-forming unit values. Prior to use in a quality-controlled environment, any new method or technology has to be shown to work as designed by the manufacturer for the purpose required. For new rapid microbiological methods that detect and enumerate contaminating microorganisms, additional recommendations have been provided in the revised PDA Technical Report No. 33. The changes include a more comprehensive review of the statistical methods to be used to analyze data obtained during validation. This paper applies those statistical methods to analyze accuracy, precision, ruggedness, and equivalence data obtained using a rapid microbiological method system being validated for water bioburden testing. The case study demonstrates that the statistical methods described in the PDA Technical Report No. 33 chapter can be successfully applied to rapid microbiological method data sets and give the same comparability results for similarity or difference as the standard method. © PDA, Inc

  17. ENZYMOCHEMICAL AND BIOCHEMICAL CHANGES IN THE LIVER OF RATS INDUCED BY FURFURAL

    Directory of Open Access Journals (Sweden)

    Dragana Veličković

    2011-06-01

    Full Text Available In today's industrial expansion of the chemical products, the liver is becoming increasingly important. Furfural (C4C3OCHO is a colorless liquid with pleasant aroma and it is partially soluble in water (8, 3% of weight. The elimination of furfural is done slowly through the kidneys and lungs, while the liver oxidizes it into pyromucic acid (C4C3OCOOH. Glucose-6-phosphate dehydrogenase (G6PD is a multi-component system of gluconeogenesis. Biochemical parameters (AST, ALT, glucose, γ-GT and alkaline phosphatase are important markers of liver damage.The aim of our study was to analyze the function of hepatocytes using biochemical parameters and to show the dynamics and topography in the development of changes in enzyme activity.The experiment was conducted on Wistar rats aged 6 weeks. The animals were divided into three groups. The control group received pure drinking water, the second group received a 50 mg/kg body weight (BW dose of furfural for seven days and in the third group the dose was progressively increased after which the animals were sacrificed. Biochemical methods were used to determine the parameters of liver damage. Enzyme-histochemical tests were performed on 8nm WKF 1150 cryostat cross sections which were stained according to Pearse (1968. The results are presented tables and graphs.The amount of enzymes and biochemical parameters in the control group were normal. In the group treated for 7 days, the activity of the enzymes was diffusely decreased while the biochemical parameters were increased. In the group of rats treated for 90 days, the periportal G6PD was constantly preserved. Biochemical parameters were different. The differences in all parameters were statistically significant (p<0.05 both in the group treated for 7 days and the group treated for 90 days. The same goes for the control group and the group treated for 7 days.Acute treatment with furfural causes damage to liver functions. The synthetic liver function is

  18. Metaanalysis of the Performance of a Combined Treponemal and Nontreponemal Rapid Diagnostic Test for Syphilis and Yaws.

    Science.gov (United States)

    Marks, Michael; Yin, Yue-Ping; Chen, Xiang-Sheng; Castro, Arnold; Causer, Louise; Guy, Rebecca; Wangnapi, Regina; Mitjà, Oriol; Aziz, Abdul; Castro, Rita; da Luz Martins Pereira, Filomena; Taleo, Fasihah; Guinard, Jérôme; Bélec, Laurent; Tun, Ye; Bottomley, Christian; Ballard, Ronald C; Mabey, David C W

    2016-09-01

    The human treponematoses are important causes of disease. Mother-to-child transmission of syphilis remains a major cause of stillbirth and neonatal death. There are also almost 100 000 cases of endemic treponemal disease reported annually, predominantly yaws. Rapid diagnostic tests (RDTs) would improve access to screening for these diseases. Most RDTs cannot distinguish current and previous infection. The Dual Path Platform (DPP) Syphilis Screen & Confirm test includes both a treponemal (T1) and nontreponemal (T2) component and may improve the accuracy of diagnosis. We conducted a metaanalysis of published and unpublished evaluations of the DPP-RDT for the diagnosis of syphilis and yaws. We calculated the sensitivity, specificity, and overall agreement of the test compared with reference laboratory tests. Nine evaluations, including 7267 tests, were included. Sensitivity was higher in patients with higher titer rapid plasma reagin (≥1:16) for both the T1 (98.2% vs 90.1%, P syphilis and yaws, although the sensitivity is decreased at lower antibody titers. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America.

  19. Rapid drug susceptibility test of mycobacterium tuberculosis by bioluminescence sensor

    Science.gov (United States)

    Lu, Bin; Xu, Shunqing; Chen, Zifei; Zhou, Yikai

    2001-09-01

    With the persisting increase of drug-resistant stains of M. Tuberculosis around the world, rapid and sensitive detection of antibiotic of M. Tuberculosis is becoming more and more important. In the present study, drug susceptibility of M. tuberculosis were detected by recombination mycobacteriophage combined with bioluminescence sensor. It is based on the use of recombination mycobacteriophage which can express firefly luciferase when it infects viable mycobacteria, and can effectively produce quantifiable photon. Meanwhile, in mycobacterium cells treated with active antibiotic, no light is observed. The emitted light is recorded by a bioluminscence sensor, so the result of drug-resistant test can be determined by the naked eye. 159 stains of M. tuberculosis were applied to this test on their resistant to rifampin, streptomycin and isoniazid. It is found that the agreement of this assay with Liewenstein- Jensen slat is: rifampin 95.60 percent, isoniazid 91.82 percent, streptomycin 88.68 percent, which showed that it is a fast and practical method to scene and detect drug resistant of mycobacterium stains.

  20. Utility of a rapid immunochromatographic strip test in detecting canine parvovirus infection compared with polymerase chain reaction

    Directory of Open Access Journals (Sweden)

    Sundaran S. Tinky

    2015-04-01

    Full Text Available Aim: The present study was undertaken to detect the presence of canine parvovirus (CPV in fecal samples of diarrheic dogs by conventional polymerase chain reaction (PCR and immunochromatographic (IC strip test and to compare the diagnostic potential of these tests. Materials and Methods: A total of 50 fecal samples collected from diarrheic dogs suspected for CPV infection were subjected to PCR using CPV-555 primer amplifying the gene coding for the VP1 protein. These samples were also tested by IC strip test using a commercial rapid Ag test kit. The results were statistically analyzed using McNemar test. Results: A total of 22 samples (44% were detected as positive by PCR, which yielded a specific amplicon of 583 bp. In IC strip test, 18 (36% samples were found to be positive. The sensitivity of the test as compared to PCR was found to be 72.22% and specificity was 92.86%. Positive predictive value and negative predictive value of IC strip test was found to be 88.89% and 81.25%, respectively. Statistical analysis of the results of PCR and IC assay using McNemar test revealed no significant difference (p>0.05. Conclusion: The IC strip test could be employed as a rapid field level diagnostic tool for the diagnosis of canine parvoviral diarrhea.

  1. Influence of Natural Honey on Biochemical and Hematological Variables in AIDS: A case study

    Directory of Open Access Journals (Sweden)

    Noori S. Al-Waili

    2006-01-01

    Full Text Available Honey lowers prostaglandins and elevates nitric oxide (NO in various biological fluids in normal persons. NO and prostaglandin play a role in pathogenesis of AIDS. The study was designed to assess the effect of natural honey on prostaglandins and NO levels, blood indices and biochemical tests in a 40 year-old woman with AIDS. This presentation is a case story of a 40 year-old women with a long history of AIDS treated with 80g of natural honey. Plasma and urinary prostaglandin F2 alpha and thromboxane B2 levels, plasma, urine and saliva content of NO-end product (total nitrite and hematological tests were estimated before and 3 hours after oral consumption of 80g of natural honey. These variables, in addition to biochemical tests, were re-estimated after 21 days of daily consumption of 80g of natural honey. Results showed that prostaglandins level compared with normal subjects were elevated in patient with AIDS. Natural honey decreased prostaglandins levels, and elevated NO-end product, percentage of lymphocytes, platelet count, and serum protein, albumin and copper levels. It might be concluded that natural honey decreased prostaglandins level, elevated NO production and improved hematological and biochemical tests in a patient with a long history of AIDS.

  2. Interim Results of a National Test of the Rapid Assessment of Hospital Procurement Barriers in Donation (RAPiD)

    Science.gov (United States)

    Traino, H. M.; Alolod, G. P.; Shafer, T.; Siminoff, L. A.

    2012-01-01

    Organ donation remains a major public health challenge with over 114 000 people on the waitlist in the United States. Among other factors, extant research highlights the need to improve the identification and timely referral of potential donors by hospital health-care providers (HCPs) to organ procurement organizations (OPOs). We implemented a national test of the Rapid Assessment of hospital Procurement barriers in Donation (RAPiD) to identify assets and barriers to the organ donation and patient referral processes; assess hospital–OPO relationships and offer tailored recommendations for improving these processes. Having partnered with seven OPOs, data were collected at 70 hospitals with high donor potential in the form of direct observations and interviews with 2358 HCPs. We found that donation attitudes and knowledge among HCPs were high, but use of standard referral criteria was lacking. Significant differences were found in the donation-related attitudes, knowledge and behaviors of physicians and emergency department staff as compared to other staff in intensive care units with high organ donor potential. Also, while OPO staff were generally viewed positively, they were often perceived as outsiders rather than members of healthcare teams. Recommendations for improving the referral and donation processes are discussed. PMID:22900761

  3. Development of a Rapid Immunodiagnostic Test for Pork Components in Raw Beef and Chicken Meats: a Preliminary Study

    Directory of Open Access Journals (Sweden)

    S. N. Depamede

    2011-08-01

    Full Text Available A rapid immunodiagnostic test that provides visual evidence of the presence of pork components in raw beef and chicken meats was developed. Colloidal gold was prepared and conjugated with anti-Swine IgG polyclonal antibody. Immunochromatographic test strips were produced, and then were used to test laboratory adulterated raw meat samples. The samples consisted adulteration meat, immunodiagnostic, pork, rapid test of pork-in-beef, or pork-in-chicken at 1/0; 1/100; 1/1,000; 1/5,000; 1/10,000 (w/w adulteration levels that were extracted in phosphate-buffered saline. Raw beef and chicken meats without pork were included as controls. Analysis was completed in 10 min. Detection limit was 1/5,000 (w/w, although 1/10,000 was also observed. This immunodiagnostic tests can be conveniently applied to detect low levels of pork components in raw beef and chicken meat products. For the commercial purposes, further studies need to be carried out.

  4. Rapid antimicrobial susceptibility testing of clinical isolates by digital time-lapse microscopy

    DEFF Research Database (Denmark)

    Fredborg, M; Rosenvinge, F S; Spillum, E

    2015-01-01

    (168 antimicrobial agent-organism combinations) demonstrated 3.6 % minor, no major and 1.2 % very major errors of the oCelloScope system compared to conventional susceptibility testing, as well as a rapid and correct phenotypic detection of strains with methicillin-resistant Staphylococcus aureus (MRSA......-to-result, enabling same-day targeted antimicrobial therapy, facilitating antibiotic stewardship and better patient management. A full-scale validation of the oCelloScope system including more isolates is necessary to assess the impact of using it for AST....

  5. Persistent negative illness perceptions despite long-term biochemical control of acromegaly: novel application of the drawing test.

    Science.gov (United States)

    Tiemensma, Jitske; Pereira, Alberto M; Romijn, Johannes A; Broadbent, Elizabeth; Biermasz, Nienke R; Kaptein, Adrian A

    2015-05-01

    Patients with acromegaly have persistent complaints despite long-term biochemical control. Drawings can be used to assess patients' perceptions about their disease. We aimed to explore the utility of the drawing test and its relation to illness perceptions and quality of life (QoL) in patients after long-term remission of acromegaly. A cross-sectional study was conducted to evaluate the utility of the drawing test. A total of 50 patients after long-term remission (mean±s.e.m., 16±1.2 years) of acromegaly were included in this study. Patients completed the drawing test (two retrospective drawings of their body perception before acromegaly and during the active phase of acromegaly, and one drawing on the current condition after long-term remission), Illness Perception Questionnaire-Revised, Physical Symptom Checklist, EuroQoL-5D, and AcroQoL. Patients perceived a dramatic change in body size during the active state of the disease compared with the healthy state before the awareness of acromegaly. Patients reported that their body did not completely return to the original proportions after long-term remission. In addition, larger drawings indicated more negative consequences (Pdrawings also indicated more impaired QoL, especially disease-specific QoL (all Pdrawing test, illness perceptions, and QoL. The drawing test appears to be a novel and relatively easy tool to assess the perception of patients after long-term remission of acromegaly. The assessment of drawings may enable health care providers to appreciate the perceptions of patients with long-term remission of acromegaly, and enable discussion of symptoms and remission. © 2015 European Society of Endocrinology.

  6. Development and testing of monoclonal antibody-based rapid immunodiagnostic test kits for direct detection of Vibrio cholerae O139 synonym Bengal.

    Science.gov (United States)

    Hasan, J A; Huq, A; Nair, G B; Garg, S; Mukhopadhyay, A K; Loomis, L; Bernstein, D; Colwell, R R

    1995-11-01

    We report on the development and testing of two monoclonal antibody-based rapid immunodiagnostic test kits, BengalScreen, a coagglutination test, and Bengal DFA, a direct fluorescent-antibody test, for direct detection of Vibrio cholerae O139 synonym Bengal in clinical and environmental specimens. The BengalScreen test requires less than 5 min to complete and can be used in the field. Bengal DFA, being more sensitive than BengalScreen, requires only one reagent and less than 20 min for detection and enumeration of V. cholerae O139 synonym Bengal. In tests for specificity, all 40 strains of V. cholerae O139 reacted with both test kits, whereas 157 strains of heterologous species examined did not, yielding 100% specificity in this study. A field trial was conducted in with both BengalScreen and Bengal DFA, and the results were compared with those obtained by conventional culture methods. BengalScreen demonstrated a sensitivity of 95%, a specificity of 100%, a positive predictive value of 100%, and a negative predictive value of 94%. Results obtained by Bengal DFA, on the other hand, were 100% sensitive and 100% specific and yielded 100% positive and negative predictive values compared with culture methods. In a second evaluation, 93 stool specimens from Mexico that were negative for V. cholerae O139 by culture were also tested with both the BengalScreen and Bengal DFA kits. None of the 93 specimens were positive for V. cholerae O139 by both tests. A concentration method was optimized for screening of environmental water samples for V. cholerae O139 synonym Bengal with rapid test kits. BengalScreen results were unequivocally positive when water samples contained at least 2.0 x 10(3) CFU/ml, whereas Bengal DFA demonstrated an unequivocally positive reaction when the water sample contained at least 1.5 x 10(2) CFU/ml. When Bengal DFA was compared with conventional culture methods for enumeration of V. cholerae O139 synonym Bengal organisms, no difference was observed.

  7. A clinical and biochemical profile of biopsy-proven non-alcoholic fatty liver disease subjects

    International Nuclear Information System (INIS)

    Khurram, M.; Mushraf, M.

    2007-01-01

    To describe clinical and biochemical features of patients with biopsy-proven non-alcoholic fatty liver disease (NAFLD). Fifty patients of either and of all ages were included, who had ultrasound evidence of fatty liver, deranged liver enzymes, and negative history of alcohol uptake. Serological/biochemical tests/markers of other liver diseases were negative. Each subject underwent liver biopsy reported by a single histopathologist. Clinical (symptoms, hypertension, hepatomegaly, and obesity) and biochemical evaluation (for diabetes, lipid abnormalities, and aspartate to alanine aminotransferase ratio (AST/ALT)) of each subject was done. Chi-square and t-tests were used for p-value calculation for finding significant difference between fatty liver and non-alcoholic steato-hepatitis groups. Thirty three (66%) patients were female and 34% were male. Mean age was 45.50+-11.50 years. Histopathologically, 62% subjects had fatty liver alone, while 38% had nonalcoholic steatohepatitis (NASH). Fatigue (100%), hypertriglyceridemia (80%), hepatomegaly (72%), AST/ALT ratio <1 (72%), and obesity/overweight (54%) were common NAFLD-related features. Except for hypertriglycedemia (p-value 0.008), no statistically significant association was noted between these features and histopathological subtypes of NAFLD. NAFLD-related clinical and biochemical features included fatigue, obesity, hepatomegaly, AST/ALT ratio <1, and hypertriglycedemia. Significant relationship existed between hypertriglyceridemia and NASH. (author)

  8. Oral rapid test: an alternative to traditional HIV screening in Chile

    Directory of Open Access Journals (Sweden)

    Lisette Paola Irarrazábal

    2013-06-01

    Full Text Available OBJECTIVE: To compare the sensitivity and specificity of an Oral Rapid Test (ORT to that of the Enzyme-Linked Immunosorbent Assay (ELISA for HIV testing in Santiago, Chile; to track the number of study participants returning for ELISA testing results; and to analyze the participants' perceptions of the ORT compared to the ELISA. METHODS: A total of 497 people were recruited in Santiago, Chile: 153 had previously tested positive for HIV, and 344 were of unknown status. Participants were tested for HIV using both the ELISA and the ORT to examine and compare specificity and sensitivity. Qualitative data were collected from 22 participants to compare perceptions of the testing experience with ORT versus ELISA. RESULTS: The ELISA reported 184 (37% of the 497 participants as being "positive" for HIV antibodies; the ORT showed 181 (36.4% as being "reactive" for HIV. The ORT showed a sensitivity of 98.4% (95.7%-99.9%, 95% Confidence Interval and specificity of 100%. The Kappa test produced K = 0.983 (P < 0.0001. Of the 344 participants whose HIV status was unknown at the start of the study, 55 failed to return for their ELISA results. Participants positively perceived ORT as having reduced both waiting time and anxiety over obtaining their test results. ORT oral swabbing appeared more practical and less invasive than drawing blood for the ELISA. CONCLUSIONS: The ORT and ELISA were statistically equal in specificity and sensitivity. ORT provides quicker results, potentially ensuring that more people receive them, and does not require handling of or exposure to potentially hazardous blood products. Trial number: ClinicalTrials.gov identifier: NCT01733927.

  9. Studies on blood and plasma biochemical characteristics of the ...

    African Journals Online (AJOL)

    The rats were fed on commercial grower mash and water provided ad libitum. Two separate blood samples were collected from the jugular veins of eight rats at 4th, 8th and 12th month stages of the experiment. One group of the samples was used for haematological studies and the other for biochemical tests. Data collected

  10. Towards benchmarking of multivariable controllers in chemical/biochemical industries: Plantwide control for ethylene glycol production

    DEFF Research Database (Denmark)

    Huusom, Jakob Kjøbsted; Bialas, Dawid Jan; Jørgensen, John Bagterp

    2011-01-01

    In this paper we discuss a simple yet realistic benchmark plant for evaluation and comparison of advanced multivariable control for chemical and biochemical processes. The benchmark plant is based on recycle-separator-recycle systems for ethylene glycol production and implemented in Matlab...... for education purposes (operator training, student education, etc) as well as scientific research into chemical process control where it enables rapid evaluation and comparison of advanced multivariable controllers as demonstrated in this study....

  11. Comparison of rapid diagnostic tests to detect Mycobacterium avium subsp. paratuberculosis disseminated infection in bovine liver.

    Science.gov (United States)

    Zarei, Mehdi; Ghorbanpour, Masoud; Tajbakhsh, Samaneh; Mosavari, Nader

    2017-08-01

    Mycobacterium avium subsp. paratuberculosis (MAP) causes Johne's disease, a chronic enteritis in cattle and other domestic and wild ruminants. The presence of MAP in tissues other than intestines and associated lymph nodes, such as meat and liver, is a potential public health concern. In the present study, the relationship between the results of rapid diagnostic tests of the Johne's disease, such as serum ELISA, rectal scraping PCR, and acid-fast staining, and the presence of MAP in liver was evaluated. Blood, liver, and rectal scraping samples were collected from 200 slaughtered cattle with unknown Johne's disease status. ELISA was performed to determine the MAP antibody activity in the serum. Acid-fast staining was performed on rectal scraping samples, and PCR was performed on rectal scraping and liver samples. PCR-positive liver samples were used for mycobacterial culture. Overall, the results of this study demonstrated that MAP can be detected and cultured from liver of slaughtered cattle and rapid diagnostic tests of Johne's disease have limited value in detecting cattle with MAP infection in liver. These findings show that the presence of MAP in liver tissue may occur in cows with negative results for rapid diagnostic tests and vice versa. Hence, liver might represent another possible risk of human exposure to MAP. Given concerns about a potential zoonotic role for MAP, these results show the necessity to find new methods for detecting cattle with MAP disseminated infection.

  12. The dynamics of blood biochemical parameters in cosmonauts during long-term space flights

    Science.gov (United States)

    Markin, Andrei; Strogonova, Lubov; Balashov, Oleg; Polyakov, Valery; Tigner, Timoty

    Most of the previously obtained data on cosmonauts' metabolic state concerned certain stages of the postflight period. In this connection, all conclusions, as to metabolism peculiarities during the space flight, were to a large extent probabilistic. The purpose of this work was study of metabolism characteristics in cosmonauts directly during long-term space flights. In the capillary blood samples taken from a finger, by "Reflotron IV" biochemical analyzer, "Boehringer Mannheim" GmbH, Germany, adapted to weightlessness environments, the activity of GOT, GPT, CK, gamma-GT, total and pancreatic amylase, as well as concentration of hemoglobin, glucose, total bilirubin, uric acid, urea, creatinine, total, HDL- and LDL cholesterol, triglycerides had been determined. HDL/LDL-cholesterol ratio also was computed. The crewmembers of 6 main missions to the "Mir" orbital station, a total of 17 cosmonauts, were examined. Biochemical tests were carryed out 30-60 days before lounch, and in the flights different stages between the 25-th and the 423-rd days of flights. In cosmonauts during space flight had been found tendency to increase, in compare with basal level, GOT, GPT, total amylase activity, glucose and total cholesterol concentration, and tendency to decrease of CK activity, hemoglobin, HDL-cholesterol concentration, and HDL/LDL — cholesterol ratio. Some definite trends in variations of other determined biochemical parameters had not been found. The same trends of mentioned biochemical parameters alterations observed in majority of tested cosmonauts, allows to suppose existence of connection between noted metabolic alterations with influence of space flight conditions upon cosmonaut's body. Variations of other studied blood biochemical parameters depends on, probably, pure individual causes.

  13. Biochemical liver function test parameter levels in relation to treatment response in liver metastatic colorectal patients treated with FOLFOX4 with or without bevacizumab

    Directory of Open Access Journals (Sweden)

    Denić Kristina

    2016-01-01

    Full Text Available Introduction. Combined use of bevacizumab and conventional anticancer drugs leads to a significant improvement of treatment response in patients with metastatic colorectal carcinoma (CRC. Conventional treatment protocols exert undesired effects on the liver tissue. Hepatotoxic effects are manifested as a disturbance of liver function test parameters. The relation between clinical outcome and disorder of biochemical parameters has not been completely evaluated. Objective. The objective of our study was to examine whether clinical outcome in patients with liver metastatic CRC correlates with the level of liver function test parameters. Methods. The study included 96 patients with untreated liver metastatic CRC who received FOLFOX4 protocol with or without bevacizumab. Biochemical liver parameters were performed before and after the treatment completion. Treatment response was evaluated as disease regression, stable disease, and disease progression. The patients were divided into three groups according to the accomplished treatment response. Results. In the group of patients with disease regression the post-treatment levels of aspartate aminotransferase, alanine aminotransferase, and bilirubin were statistically significantly increased. In contrast to this, gamma-glutamyltransferase and protein post-treatment values were significantly lower in relation to initial values. In patients with stable disease, difference was found only in the level of proteins being lower after the treatment. In patients with disease progression, values of aspartate aminotransferase and bilirubin were significantly increased after completed treatment. Conclusion. Treatment responses are not completely associated with the level of liver function test parameters. The only parameter which correlated with treatment response is gamma-glutamyltransferase. Its decrease is accompanied with disease regression.

  14. Clinical and pathologic factors predictive of biochemical control following post-prostatectomy irradiation

    International Nuclear Information System (INIS)

    Stromberg, Jannifer S.; Ziaja, Ellen L.; Horwitz, Eric M.; Vicini, Frank A.; Brabbins, Donald S.; Dmuchowski, Carl F.; Gonzalez, Jose; Martinez, Alvaro A.

    1996-01-01

    Purpose/Objective: Indications for post-prostatectomy radiation therapy are not well defined. We reviewed our experience treating post-prostatectomy patients with external beam irradiation to assess clinical and pathologic factors predictive of biochemical control. Materials and Methods: Between 1/87 and 3/93, 61 patients received post-operative tumor bed irradiation with a median dose of 59.4 Gy (50.4 - 68 Gy). Median follow-up was 4.1 years (7.6 months - 8.3 years) from irradiation. Patients were treated for the following reasons: 1) adjuvantly, within 6 months of surgery for extracapsular extension, seminal vesicle involvement, or positive surgical margins (n=38); 2) persistently elevated PSA post-operatively (n=2); 3) rising PSA >6 months after surgery (n=9); and 4) biopsy proven local recurrence (n=12). No patients had known nodal or metastatic disease. All patients had post-radiation PSA data available. Biochemical control was the endpoint studied using Kaplan-Meier life table analysis. Biochemical control was defined as the ability to maintain an undetectable PSA ( 4 and ≤1 0, >10 and ≤20, and > 20 ng/ml. The 3 year actuarial rates of biochemical control were 100% for group 1, 66.7% for group 2, 61.5% for group 3, and 28.6% for group 4. Pre-RT PSA values were also evaluated. Univariate Cox models indicated lower presurgical and pre-RT PSA values were predictive of biochemical control (p=0.017, p 6 months after surgery (group 3), the 3 year actuarial rate of biochemical control was 55.6%. The 3 year actuarial rate of biochemical control for patients treated for a biopsy proven recurrence (group 4) was 8.3%. By pair-wise log rank test, the rates of biochemical control were significantly different between groups 1 and 3 (p=0.036), groups 1 and 4 (p<0.001), and groups 3 and 4 (p=0.009). Conclusion: Biochemical control was achieved in approximately half of the patients treated with post-operative prostatic fossa irradiation. Elevated presurgical and pre

  15. The biochemical anatomy of cortical inhibitory synapses.

    Directory of Open Access Journals (Sweden)

    Elizabeth A Heller

    Full Text Available Classical electron microscopic studies of the mammalian brain revealed two major classes of synapses, distinguished by the presence of a large postsynaptic density (PSD exclusively at type 1, excitatory synapses. Biochemical studies of the PSD have established the paradigm of the synapse as a complex signal-processing machine that controls synaptic plasticity. We report here the results of a proteomic analysis of type 2, inhibitory synaptic complexes isolated by affinity purification from the cerebral cortex. We show that these synaptic complexes contain a variety of neurotransmitter receptors, neural cell-scaffolding and adhesion molecules, but that they are entirely lacking in cell signaling proteins. This fundamental distinction between the functions of type 1 and type 2 synapses in the nervous system has far reaching implications for models of synaptic plasticity, rapid adaptations in neural circuits, and homeostatic mechanisms controlling the balance of excitation and inhibition in the mature brain.

  16. Behavioral and biochemical dissociation of arousal and homeostatic sleep need influenced by prior wakeful experience in mice.

    Science.gov (United States)

    Suzuki, Ayako; Sinton, Christopher M; Greene, Robert W; Yanagisawa, Masashi

    2013-06-18

    Sleep is regulated by homeostatic mechanisms, and the low-frequency power in the electroencephalogram (delta power) during non-rapid eye movement sleep reflects homeostatic sleep need. Additionally, sleep is limited by circadian and environmentally influenced arousal. Little is known, however, about the underlying neural substrates for sleep homeostasis and arousal and about the potential link between them. Here, we subjected C57BL/6 mice to 6 h of sleep deprivation using two different methods: gentle handling and continual cage change. Both groups were deprived of sleep to a similar extent (>99%), and, as expected, the delta power increase during recovery sleep was quantitatively similar in both groups. However, in a multiple sleep latency test, the cage change group showed significantly longer sleep latencies than the gentle handling group, indicating that the cage change group had a higher level of arousal despite the similar sleep loss. To investigate the possible biochemical correlates of these behavioral changes, we screened for arousal-related and sleep need-related phosphoprotein markers from the diencephalon. We found that the abundance of highly phosphorylated forms of dynamin 1, a presynaptic neuronal protein, was associated with sleep latency in the multiple sleep latency test. In contrast, the abundance of highly phosphorylated forms of N-myc downstream regulated gene 2, a glial protein, was increased in parallel with delta power. The changes of these protein species disappeared after 2 h of recovery sleep. These results suggest that homeostatic sleep need and arousal can be dissociated behaviorally and biochemically and that phosphorylated N-myc downstream regulated gene 2 and dynamin 1 may serve as markers of homeostatic sleep need and arousal, respectively.

  17. Rapid susceptibility testing of Mycobacterium tuberculosis by bioluminescence assay of mycobacterial ATP

    International Nuclear Information System (INIS)

    Nilsson, L.E.; Hoffner, S.E.; Ansehn, S.

    1988-01-01

    Mycobacterial growth was monitored by bioluminescence assay of mycobacterial ATP. Cultures of Mycobacterium tuberculosis H37Rv and of 25 clinical isolates of the same species were exposed to serial dilutions of ethambutol, isoniazid, rifampin, and streptomycin. A suppression of ATP, indicating growth inhibition, occurred for susceptible but not resistant strains within 5 to 7 days of incubation. Breakpoint concentrations between susceptibility and resistance were determined by comparing these results with those obtained by reference techniques. Full agreement was found in 99% of the assays with the resistance ratio method on Lowenstein-Jensen medium, and 98% of the assays were in full agreement with the radiometric system (BACTEC). A main advantage of the bioluminescence method is its rapidity, with results available as fast as with the radiometric system but at a lower cost and without the need for radioactive culture medium. The method provides kinetic data concerning drug effects within available in vivo drug concentrations and has great potential for both rapid routine susceptibility testing and research applications in studies of drug effects on mycobacteria

  18. Evaluating quality management systems for HIV rapid testing services in primary healthcare clinics in rural KwaZulu-Natal, South Africa.

    Directory of Open Access Journals (Sweden)

    Ziningi Jaya

    Full Text Available Rapid HIV tests have improved access to HIV diagnosis and treatment by providing quick and convenient testing in rural clinics and resource-limited settings. In this study, we evaluated the quality management system for voluntary and provider-initiated point-of-care HIV testing in primary healthcare (PHC clinics in rural KwaZulu-Natal (KZN, South Africa.We conducted a quality assessment audit in eleven PHC clinics that offer voluntary HIV testing and counselling in rural KZN, South Africa from August 2015 to October 2016. All the participating clinics were purposively selected from the province-wide survey of diagnostic services. We completed an on-site monitoring checklist, adopted from the WHO guidelines for assuring accuracy and reliability of HIV rapid tests, to assess the quality management system for HIV rapid testing at each clinic. To determine clinic's compliance to WHO quality standards for HIV rapid testing the following quality measure was used, a 3-point scale (high, moderate and poor. A high score was defined as a percentage rating of 90 to 100%, moderate was defined as a percentage rating of 70 to 90%, and poor was defined as a percentage rating of less than 70%. Clinic audit scores were summarized and compared. We employed Pearson pair wise correlation coefficient to determine correlations between clinics audit scores and clinic and clinics characteristics. Linear regression model was computed to estimate statistical significance of the correlates. Correlations were reported as significant at p ≤0.05.Nine out of 11 audited rural PHC clinics are located outside 20Km of the nearest town and hospital. Majority (18.2% of the audited rural PHC clinics reported that HIV rapid test was performed by HIV lay counsellors. Overall, ten clinics were rated moderate, in terms of their compliance to the stipulated WHO guidelines. Audit results showed that rural PHC clinics' average rating score for compliance to the WHO guidelines ranged

  19. Evaluating quality management systems for HIV rapid testing services in primary healthcare clinics in rural KwaZulu-Natal, South Africa.

    Science.gov (United States)

    Jaya, Ziningi; Drain, Paul K; Mashamba-Thompson, Tivani P

    2017-01-01

    Rapid HIV tests have improved access to HIV diagnosis and treatment by providing quick and convenient testing in rural clinics and resource-limited settings. In this study, we evaluated the quality management system for voluntary and provider-initiated point-of-care HIV testing in primary healthcare (PHC) clinics in rural KwaZulu-Natal (KZN), South Africa. We conducted a quality assessment audit in eleven PHC clinics that offer voluntary HIV testing and counselling in rural KZN, South Africa from August 2015 to October 2016. All the participating clinics were purposively selected from the province-wide survey of diagnostic services. We completed an on-site monitoring checklist, adopted from the WHO guidelines for assuring accuracy and reliability of HIV rapid tests, to assess the quality management system for HIV rapid testing at each clinic. To determine clinic's compliance to WHO quality standards for HIV rapid testing the following quality measure was used, a 3-point scale (high, moderate and poor). A high score was defined as a percentage rating of 90 to 100%, moderate was defined as a percentage rating of 70 to 90%, and poor was defined as a percentage rating of less than 70%. Clinic audit scores were summarized and compared. We employed Pearson pair wise correlation coefficient to determine correlations between clinics audit scores and clinic and clinics characteristics. Linear regression model was computed to estimate statistical significance of the correlates. Correlations were reported as significant at p ≤0.05. Nine out of 11 audited rural PHC clinics are located outside 20Km of the nearest town and hospital. Majority (18.2%) of the audited rural PHC clinics reported that HIV rapid test was performed by HIV lay counsellors. Overall, ten clinics were rated moderate, in terms of their compliance to the stipulated WHO guidelines. Audit results showed that rural PHC clinics' average rating score for compliance to the WHO guidelines ranged between 64.4% (CI

  20. [Evaluation of a rapid diagnostic test in the diagnosis of toxoplasmosis in pregnant women in Cotonou (Bénin)].

    Science.gov (United States)

    Ogouyèmi-Hounto, A; Agbayahoun-Chokki, F; Sissinto Savi de Tove, Y; Biokou Bankole, B; Adinsi de Souza, V; Assogba, M; Kinde-Gazard, D; Massougbodji, A

    2014-05-01

    The aim of the study was to evaluate the performance of the ImmunoComb® Toxo IgG and ImmunoComb® Toxo IgMassays (rapid diagnostic test) in the laboratory diagnosis of toxoplasmosis in pregnant women in Cotonou. We interviewed 266 pregnant women, who first answered an epidemiological questionnaire, and collected blood samples for measurement of IgG and IgM anti T. gondii antibodies with the ImmunoComb toxo assays and with the ARCHITECT CIMA method. The sensitivity, specificity, positive predictive values (PPV) and negative predictive values (NPV) were calculated to determine the performance of the rapid test. The seroprevalences of IgG against T. gondii by CIMA technique and rapid test were respectively 48.9% and 48.5%. The prevalence increased with age. Performances for IgG were: sensitivity 97%, specificity 100%, PPV 100%, NPV = 97.10%. For IgM, Sensitivity: 33.3% Specificity: 100%, PPV 100%, NPV = 99.2%. Seroprevalence obtained shows that about half of the study population is not immune against T. gondii and requires regular serological monitoring until delivery. According to these results, and given the needs of toxoplasmosis diagnosis on the field characterized by an important decrease of immunized women, this test may be recommended in the laboratory diagnosis of toxoplasmosis in peripheral levels of the health pyramid.

  1. Efficiency of a clinical prediction model for selective rapid testing in children with pharyngitis: A prospective, multicenter study

    NARCIS (Netherlands)

    Cohen, Jérémie F.; Cohen, Robert; Bidet, Philippe; Elbez, Annie; Levy, Corinne; Bossuyt, Patrick M.; Chalumeau, Martin

    2017-01-01

    There is controversy whether physicians can rely on signs and symptoms to select children with pharyngitis who should undergo a rapid antigen detection test (RADT) for group A streptococcus (GAS). Our objective was to evaluate the efficiency of signs and symptoms in selectively testing children with

  2. Hemagglutinin Typing as an Aid in Identification of Biochemically Atypical Escherichia coli Strains

    OpenAIRE

    Crichton, Pamela B.; Ip, S. M.; Old, D. C.

    1981-01-01

    Tests for the presence of mannose-sensitive and mannose-resistant, eluting hemagglutinins and fimbriae were helpful in indicating whether biochemically atypical strains of the tribe Escherichieae might be escherichiae or shigellae.

  3. DEPIVIH 2: Use of three HIV testing methods in French primary care settings - ELISA laboratory screening versus two rapid point-of-care HIV tests.

    Science.gov (United States)

    Papadima, D; Gauthier, R; Prévoteau du Clary, F; Bouée, S; Conort, G; Livrozet, J-M; Taulera, O; Wajsbrot, A; Majerholc, C; Peter, J-M; Aubert, J-P

    2018-03-01

    The primary endpoint was to evaluate the use of HIV testing methods by French primary care providers: Elisa laboratory screening, instant result HIV diagnostic test and rapid result HIV diagnostic test. The secondary endpoints were the population screening rate of unknown HIV status consulting during the study period, reasons for screening and for choosing the specific screening method, the investigators' satisfaction with the rapid diagnostic test (RDT) and problems encountered. National prospective interventional study with French family physicians (FP) from December 2013 to December 2014. FPs enrolled all consenting adults consulting for an HIV screening test during a 6-month period: the choice was an Elisa laboratory test or one of the two RDTs. During the study period, 43 FPs included 981 patients. HIV screening was performed for the first time for 31.6% of patients; 767 (78.2%) Elisa laboratory test prescriptions and 214 (21.8%) RDTs were performed, leading to a screening rate of 1.3%. For 120 (15.7%) of the Elisa laboratory tests, the result was not reported and six RDTs were not valid. Nine patients were diagnosed as HIV-infected (0.9%): five with Elisa laboratory test and four with RDT. Almost 90% of FPs were willing to keep on using RDTs in their daily practice. In general practice, RDTs may be an important additional tool to traditional HIV screening. They could account for one in five tests prescribed in this context. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  4. Fluoromycobacteriophages for Rapid, Specific, and Sensitive Antibiotic Susceptibility Testing of Mycobacterium tuberculosis

    Science.gov (United States)

    Piuri, Mariana; Jacobs, William R.; Hatfull, Graham F.

    2009-01-01

    Rapid antibiotic susceptibility testing of Mycobacterium tuberculosis is of paramount importance as multiple- and extensively- drug resistant strains of M. tuberculosis emerge and spread. We describe here a virus-based assay in which fluoromycobacteriophages are used to deliver a GFP or ZsYellow fluorescent marker gene to M. tuberculosis, which can then be monitored by fluorescent detection approaches including fluorescent microscopy and flow cytometry. Pre-clinical evaluations show that addition of either Rifampicin or Streptomycin at the time of phage addition obliterates fluorescence in susceptible cells but not in isogenic resistant bacteria enabling drug sensitivity determination in less than 24 hours. Detection requires no substrate addition, fewer than 100 cells can be identified, and resistant bacteria can be detected within mixed populations. Fluorescence withstands fixation by paraformaldehyde providing enhanced biosafety for testing MDR-TB and XDR-TB infections. PMID:19300517

  5. Direct nitrate reductase assay versus microscopic observation drug susceptibility test for rapid detection of MDR-TB in Uganda.

    Directory of Open Access Journals (Sweden)

    Freddie Bwanga

    Full Text Available The most common method for detection of drug resistant (DR TB in resource-limited settings (RLSs is indirect susceptibility testing on Lowenstein-Jensen medium (LJ which is very time consuming with results available only after 2-3 months. Effective therapy of DR TB is therefore markedly delayed and patients can transmit resistant strains. Rapid and accurate tests suitable for RLSs in the diagnosis of DR TB are thus highly needed. In this study we compared two direct techniques--Nitrate Reductase Assay (NRA and Microscopic Observation Drug Susceptibility (MODS for rapid detection of MDR-TB in a high burden RLS. The sensitivity, specificity, and proportion of interpretable results were studied. Smear positive sputum was collected from 245 consecutive re-treatment TB patients attending a TB clinic in Kampala, Uganda. Samples were processed at the national reference laboratory and tested for susceptibility to rifampicin and isoniazid with direct NRA, direct MODS and the indirect LJ proportion method as reference. A total of 229 specimens were confirmed as M. tuberculosis, of these interpretable results were obtained in 217 (95% with either the NRA or MODS. Sensitivity, specificity and kappa agreement for MDR-TB diagnosis was 97%, 98% and 0.93 with the NRA; and 87%, 95% and 0.78 with the MODS, respectively. The median time to results was 10, 7 and 64 days with NRA, MODS and the reference technique, respectively. The cost of laboratory supplies per sample was low, around 5 USD, for the rapid tests. The direct NRA and MODS offered rapid detection of resistance almost eight weeks earlier than with the reference method. In the study settings, the direct NRA was highly sensitive and specific. We consider it to have a strong potential for timely detection of MDR-TB in RLS.

  6. Effect of toxoplasmosis and brucellosis on some biochemical parameters in ewes

    Directory of Open Access Journals (Sweden)

    N. A. J. Al- Hussary

    2010-01-01

    Full Text Available The present study was conducted to evaluate the effects of infection of ewes with toxoplasmosis and/or brucellosis on someserum biochemical parameters. Ninety six samples of blood were collected from aborted ewes at different stages of gestation,suspected to be infected with toxoplasmosis and /or brucellosis from different regions in Nineveh governorate. The percentageof toxoplasma and brucella infection depending on Latex Agglutination Test (LAT and Rose Bengal Test were 21.88% and23.96% respectively. The results of biochemical analysis showed that infection with toxoplasma caused significant elevation ofserum activities of aspartate aminotransferase (AST, alanine aminotransferase (ALT and lactate dehydrogenase (LDH. Aswell as the concentrations of glucose, total protein and copper. Where as the activity of alkaline phosphatase (ALP and theconcentration of calcium and zinc were reduced. Infection with brucellosis caused a significant increased in serum AST, ALTand LDH, ALP and creatin phosphokinase (CPK activities, and glucose, zinc and cholesterol concentrations. While serumcalcium and total protein concentration were decreased. Association of toxoplasma and brucella infection induced significantelevation of serum AST, ALT and LDH and CPK activities and the concentrations of glucose and copper with significant reduction in serum ALP activity and both calcium and zinc concentrations. It was concluded from this study that infection ofewes with toxoplasma and/or brucella caused changes in some biochemical parameters in the serum.

  7. Opium and heroin alter biochemical parameters of human's serum.

    Science.gov (United States)

    Kouros, Divsalar; Tahereh, Haghpanah; Mohammadreza, Afarinesh; Minoo, Mahmoudi Zarandi

    2010-05-01

    Iran is a significant consumer of opium, and, generally, of opioids, in the world. Addiction is one of the important issues of the 21st century and is an imperative issue in Iran. Long-term consumption of opioids affects homeostasis. To determine the effects of opium and heroin consumption on serum biochemical parameters. In a cross-sectional study, subjects who had consumed heroin (n = 35) or opium (n = 42) for more than two years and 35 nonaddict volunteers as the control group were compared in regard to various biochemical parameters such as fasting blood sugar (FBS), Na(+), K(+), Ca(2+), blood urea nitrogen (BUN), uric acid (UA), triglyceride (TG), cholesterol, creatinine, and total protein. Chromatography was used to confirm opioid consumption, and the concentration of biochemical parameters was determined by laboratory diagnostic tests on serum. No significant differences were found in Na(+), Ca(2+), BUN, UA, TG, creatinine, and total protein concentrations among the three groups. FBS, K(+), and UA levels were significantly lower in opium addicts compared to the control group. Serum Ca(2+) concentration of heroin addicts showed a significant decrease compared to that of the control group. Both addict groups showed a significant decrease in serum cholesterol levels. Chronic use of opium and heroin can change serum FBS, K(+), Ca(2+), UA, and cholesterol. This study, one of few on the effects of opium on serum biochemical parameters in human subjects, has the potential to contribute to the investigation of new approaches for further basic studies.

  8. HIV rapid testing in the framework of an STI prevention project on a cohort of vulnerable Italians and immigrants.

    Science.gov (United States)

    Uccella, Ilaria; Petrelli, Alessio; Vescio, Maria Fenicia; De Carolis, Silvia; Fazioli, Cecilia; Pezzotti, Patrizio; Rezza, Gianni

    2017-08-01

    Uptake of HIV tests is a challenging issue in vulnerable populations including immigrants, normally using standard diagnostic tools. Objectives of this study were to evaluate the acceptability of HIV rapid test; estimate the percentage of newly HIV diagnoses and evaluate knowledge, attitudes and perception (KAP) about HIV/AIDS and other STIs in a specific set of immigrants and vulnerable population in Rome (Italy). All immigrant and Italian people, aged 16-70 years, attending the infectious disease outpatient clinic of the National Institute for Health, Migration and Poverty (INMP) in Rome (Italy), during the period December 2012 to December 2013 were enrolled. HIV rapid testing was provided for free and patients were asked to fill in a questionnaire evaluating KAP about HIV/STIs. All patients with risky sexual behaviours or with a recent diagnosis of STIs were invited to come back after 3-6 months and a post-counselling questionnaire was offered. Out of the total sample, 99.2% (n = 825) accepted the "rapid test" and 10 new HIV diagnoses were found (1.22%; 95% CI 0.58%-2.22%). Three hundred and eighty-five participants (47%) answered the entry questionnaire and 58 (15%) completed the follow-up. Overall, we found high knowledge about HIV/AIDS; however, lower educational level and immigrant status were associated with poor knowledge about HIV, other STIs and prevention methods. Immigrants have lower perception of sexual risk and higher prejudice than Italians. Our study showed high acceptance of rapid test in this specific vulnerable population and this allowed to identify new HIV diagnoses in unaware people. Socioeconomic inequalities observed in the KAP questionnaire suggest the need for actions to support the reduction of cultural differences in knowledge of HIV/AIDS and for policies aimed at improving access to health services and preventions programmes of marginalized populations.

  9. Rapid BRAF mutation tests in patients with advanced melanoma : Comparison of immunohistochemistry, Droplet Digital PCR, and the Idylla Mutation Platform

    NARCIS (Netherlands)

    Bisschop, Cornelis; Ter Elst, Arja; Bosman, Lisette J; Platteel, Inge; Jalving, Mathilde; van den Berg, Anke; Diepstra, Arjan; van Hemel, Bettien; Diercks, Gilles F H; Hospers, Geke A P; Schuuring, Ed

    BRAF mutational testing has become a common practice in the diagnostic process of patients with advanced melanoma. Although time-consuming, DNA sequencing techniques are the current gold standard for mutational testing. However, in certain clinical situations, a rapid test result is required. In

  10. Electronic vending machines for dispensing rapid HIV self-testing kits: a case study.

    Science.gov (United States)

    Young, Sean D; Klausner, Jeffrey; Fynn, Risa; Bolan, Robert

    2014-02-01

    This short report evaluates the feasibility of using electronic vending machines for dispensing oral, fluid, rapid HIV self-testing kits in Los Angeles County. Feasibility criteria that needed to be addressed were defined as: (1) ability to find a manufacturer who would allow dispensing of HIV testing kits and could fit them to the dimensions of a vending machine, (2) ability to identify and address potential initial obstacles, trade-offs in choosing a machine location, and (3) ability to gain community approval for implementing this approach in a community setting. To address these issues, we contracted a vending machine company who could supply a customized, Internet-enabled machine that could dispense HIV kits and partnered with a local health center available to host the machine onsite and provide counseling to participants, if needed. Vending machines appear to be feasible technologies that can be used to distribute HIV testing kits.

  11. Diagnostic accuracy of the rapid urine lipoarabinomannan test for pulmonary tuberculosis among HIV-infected adults in Ghana-findings from the DETECT HIV-TB study

    DEFF Research Database (Denmark)

    Bjerrum, Stephanie; Kenu, Ernest; Lartey, Margaret

    2015-01-01

    BACKGROUND: Rapid diagnostic tests are urgently needed to mitigate HIV-associated tuberculosis (TB) mortality. We evaluated diagnostic accuracy of the rapid urine lipoarabinomannan (LAM) test for pulmonary TB and assessed the effect of a two-sample strategy. METHODS: HIV-infected adults eligible...

  12. Field evaluation of a dual rapid diagnostic test for HIV infection and syphilis in Lima, Peru.

    Science.gov (United States)

    Bristow, Claire C; Leon, Segundo R; Huang, Emily; Brown, Brandon J; Ramos, Lourdes B; Vargas, Silver K; Flores, Juan A; Caceres, Carlos F; Klausner, Jeffrey D

    2016-05-01

    Screening for HIV and syphilis in key populations is recommended by the WHO to reduce the morbidity, mortality and transmission associated with undiagnosed and untreated infections. Rapid point-of-care tests that can detect multiple infections with a single fingerprick whole blood specimen using a single device are gaining popularity. We evaluated the field performance of a rapid dual HIV and syphilis test in people at high risk of HIV and syphilis infections. Participants included men who have sex with men and transgender women recruited in Lima, Peru. Reference standard testing for detection of HIV and syphilis infections, conducted using blood samples from venipuncture, included Treponema pallidum particle agglutination and fourth-generation HIV enzyme immunoassay for which positive results had a confirmation HIV Western blot test. For the evaluation test, SD BIOLINE HIV/Syphilis Duo test (Standard Diagnostics, Korea), a fingerprick blood specimen was used. Sensitivity and specificity were calculated and the exact binomial method was used to determine 95% CIs. A total of 415 participants were recruited for the study. The dual test sensitivity for detection of T. pallidum infection was 89.2% (95% CI 83.5% to 93.5%) and specificity 98.8% (95% CI 96.5% to 99.8%). For detection of HIV infection, the sensitivity of the dual test was 99.1% (95% CI 94.8% to 100%) and specificity 99.4% (95% CI 97.7% to 99.9%). This high performing dual test should be considered for the use in clinical settings to increase uptake of simultaneous testing of HIV and syphilis and accelerate time to treatment for those who need it. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  13. Hemagglutinin Typing as an Aid in Identification of Biochemically Atypical Escherichia coli Strains

    Science.gov (United States)

    Crichton, Pamela B.; Ip, S. M.; Old, D. C.

    1981-01-01

    Tests for the presence of mannose-sensitive and mannose-resistant, eluting hemagglutinins and fimbriae were helpful in indicating whether biochemically atypical strains of the tribe Escherichieae might be escherichiae or shigellae. PMID:7334072

  14. How sensitive and specific is urinalysis 'dipstick' testing for detection of hyperglycaemia and ketosis? An audit of findings from coronial autopsies.

    Science.gov (United States)

    Mitchell, Rebecca; Thomas, Sunethra Devika; Langlois, Neil E I

    2013-10-01

    Biochemical analysis of glucose and ketones in the vitreous humour obtained at post-mortem examination is representative of the levels in the blood prior to death. Elevated levels can be indicative of conditions including diabetic ketoacidosis, which can be a cause for unexpected death. A rapid screening test for such conditions can be performed during the autopsy through urinalysis using test strips (urine 'dipstick' testing). The aim of this study was to assess the utility of urinalysis testing for post-mortem detection of derangements of glucose and ketone levels. The results of vitreous biochemical analysis and urinalysis were collated from 188 forensic autopsy cases. A vitreous glucose result of above 10 mmol/L was regarded as high. When this was compared to urinalysis results it was found that any urinalysis result above negative had a sensitivity of 0.83 and a specificity of 0.93. A vitreous ketone level of above 5 mmol/L was regarded as significantly elevated; a urinalysis result above negative had a sensitivity of 1, but a specificity of 0.12. Urinalysis ('dipstick' testing) for glucose has a good sensitivity and specificity for high vitreous glucose levels, which are regarded as indicative of pathological hyperglycaemia during life. It was found that urine testing for ketones either has an excellent sensitivity with low specificity or a poor sensitivity with a good specificity; however, this finding has to be viewed in the context of uncertainty of the biochemical level of significant ketosis.

  15. Biochemical characterization of cholesterol-reducing Eubacterium.

    Science.gov (United States)

    Mott, G E; Brinkley, A W; Mersinger, C L

    1980-12-01

    We characterized two isolates of cholesterol-reducing Eubacterium by conducting conventional biochemical tests and by testing various sterols and glycerolipids as potential growth factors. In media containing cholesterol and plasmenylethanolamine, the tests for nitrate reduction, indole production, and gelatin and starch hydrolyses were negative, and no acid was produced from any of 22 carbohydrates. Both isolates hydrolyzed esculin to esculetin, indicating beta-glycosidase activity. In addition to plasmenylethanolamine, five other lipids which contain an alkenyl ether residue supported growth of Eubacterium strain 403 in a lecithin-cholesterol base medium. Of six steroids tested, cholesterol, cholest-4-en-3-one, cholest-4-en-3 beta-ol (allocholesterol), and androst-5-en-3 beta-ol-17-one supported growth of Eubacterium strain 403. All four steroids were reduced to the 3 beta-ol, 5 beta-H products. The delta 5 steroids cholest-5-en-3 alpha-ol (epicholesterol) and 22,23-bisnor-5-cholenic acid-3-beta-ol were not reduced and did not support growth of the Eubacterium strain.

  16. Preparation and Testing of Impedance-based Fluidic Biochips with RTgill-W1 Cells for Rapid Evaluation of Drinking Water Samples for Toxicity

    Science.gov (United States)

    2016-03-07

    109 | e53555 | Page 1 of 8 Video Article Preparation and Testing of Impedance-based Fluidic Biochips with RTgill-W1 Cells for Rapid Evaluation of...www.jove.com/ video /53555 DOI: doi:10.3791/53555 Keywords: Environmental Sciences, Issue 109, Fish cells, impedance, sensors, biochip, water toxicity...sensitivity to cholinesterase-inhibiting pesticides . Applications for this toxicity detector are for rapid field-portable testing of drinking water

  17. Studies on some biochemical parameters in viral hepatitis patients

    International Nuclear Information System (INIS)

    El-Sherbiny, E.M.

    2002-01-01

    The present investigation deals with studying liver amino transferases (ALT. AST). Cholesterol and triglycerides. As well as testosterone and protection hormones in blood of Egyptian men infected with hepatitis C virus.hepatitis B virus and mixed B and C viruses. These biochemical parameters were evaluated to be used in diagnosis and prognosis of viral hepatitis. Which considered the most important health problem in Egypt and developing countries. Biochemical analysis were performed using spectrophotometric and radioimmunoassay techniques. All data will be subjected to statistical analysis in order to detect the most suitable biochemical analysis that can be used as specific tests for early diagnosis of viral hepatitis and to detect the parameters that show abnormalities among the different groups of infected patients. The data revealed that AST and ALT levels were increased in all patient groups. Concerning the level of triglycerides, it was increased only in the group of mixed viral hepatitis B and C, while cholesterol showed non-significant changes in all viral hepatitis groups. The sex hormone testosterone was decreased in all infected patients while the prolactin level was increased only in case of patients infected with mixed B and C viruses. However, these abnormal values in such sex hormones play a serious role in male sterility

  18. A cross-sectional survey of attitudes to HIV risk and rapid HIV testing among clients of sex workers in Switzerland.

    Science.gov (United States)

    Darling, Katharine E A; Diserens, Esther-Amélie; N'garambe, Chantal; Ansermet-Pagot, Anne; Masserey, Eric; Cavassini, Matthias; Bodenmann, Patrick

    2012-10-01

    To assess attitudes to HIV risk and acceptability of rapid HIV testing among clients of street-based female sex workers (FSW) in Lausanne, Switzerland, where HIV prevalence in the general population is 0.4%. The authors conducted a cross-sectional study in the red light district of Lausanne for five nights in September of 2008, 2009 and 2010. Clients of FSW were invited to complete a questionnaire in the street assessing demographic characteristics, attitudes to HIV risk and HIV testing history. All clients interviewed were then offered anonymous finger stick rapid HIV testing in a van parked on-site. The authors interviewed 112, 127 and 79 clients in 2008, 2009 and 2010, respectively. All were men, average age 32-37 years old; 40-60% were in a stable relationship. History of unprotected sex was higher with non-commercial partners (33-50%) than with FSW (6-11%); 29-46% of clients had never undergone an HIV test. Anonymous rapid HIV testing was accepted by 45-50% of clients. Out of 109 HIV tests conducted during the three study periods, none was reactive. On-site HIV counselling and testing is acceptable among clients of FSW in this urban setting. These individuals represent an unquantified population, a proportion of which has an incomplete understanding of HIV risk in the face of high-risk behaviour, with implications for potential onward transmission to non-commercial sexual partners.

  19. The use of an automated flight test management system in the development of a rapid-prototyping flight research facility

    Science.gov (United States)

    Duke, Eugene L.; Hewett, Marle D.; Brumbaugh, Randal W.; Tartt, David M.; Antoniewicz, Robert F.; Agarwal, Arvind K.

    1988-01-01

    An automated flight test management system (ATMS) and its use to develop a rapid-prototyping flight research facility for artificial intelligence (AI) based flight systems concepts are described. The ATMS provides a flight test engineer with a set of tools that assist in flight planning and simulation. This system will be capable of controlling an aircraft during the flight test by performing closed-loop guidance functions, range management, and maneuver-quality monitoring. The rapid-prototyping flight research facility is being developed at the Dryden Flight Research Facility of the NASA Ames Research Center (Ames-Dryden) to provide early flight assessment of emerging AI technology. The facility is being developed as one element of the aircraft automation program which focuses on the qualification and validation of embedded real-time AI-based systems.

  20. INVESTIGATIONS ON BIOCHEMICAL PURIFICATION OF GROUND WATER FROM HYDROGEN SULFIDE

    Directory of Open Access Journals (Sweden)

    Yu. P. Sedlukho

    2015-01-01

    Full Text Available The paper considers problems and features of biochemical removal of hydrogen sulfide from ground water. The analysis of existing methods for purification of ground water from hydrogen sulfide has been given in the paper. The paper has established shortcomings of physical and chemical purification of ground water. While using aeration methods for removal of hydrogen sulfide formation of colloidal sulfur that gives muddiness and opalescence to water occurs due to partial chemical air oxidation. In addition to this violation of sulfide-carbonate equilibrium taking place in the process of aeration due to desorption of H2S and CO2, often leads to clogging of degasifier nozzles with formed CaCO3 that causes serious operational problems. Chemical methods require relatively large flow of complex reagent facilities, storage facilities and transportation costs.In terms of hydrogen sulfide ground water purification the greatest interest is given to the biochemical method. Factors deterring widespread application of the biochemical method is its insufficient previous investigation and necessity to execute special research in order to determine optimal process parameters while purifying groundwater of a particular water supply source. Biochemical methods for oxidation of sulfur compounds are based on natural biological processes that ensure natural sulfur cycle. S. Vinogradsky has established a two-stage mechanism for oxidation of hydrogen sulfide with sulfur bacteria (Beggiatoa. The first stage presupposes oxidation of hydrogen sulphide to elemental sulfur which is accumulating in the cytoplasm in the form of globules. During the second stage sulfur bacteria begin to oxidize intracellular sulfur to sulfuric acid due to shortage of hydrogen sulfide.The paper provides the results of technological tests of large-scale pilot plants for biochemical purification of groundwater from hydrogen sulfide in semi-industrial conditions. Dependences of water quality

  1. Distinct Neuropsychological Mechanisms May Explain Delayed- Versus Rapid-Onset Antidepressant Efficacy

    Science.gov (United States)

    Stuart, Sarah A; Butler, Paul; Munafò, Marcus R; Nutt, David J; Robinson, Emma SJ

    2015-01-01

    The biochemical targets for antidepressants are relatively well established, but we lack a clear understanding of how actions at these proteins translate to clinical benefits. This study used a novel rodent assay to investigate how different antidepressant drugs act to modify affective biases that have been implicated in depression. In this bowl-digging task, rats encounter two equal value learning experiences on separate days (one during an affective manipulation and the other during control conditions). This induces an affective bias that is quantified using a preference test in which both digging substrates are presented together and the individual rats’ choices recorded. The assay can be used to measure affective biases associated with learning (when the treatment is given at the time of the experience) or examine the modification of previously acquired biases (when the treatment is administered before the preference test). The rapid-onset antidepressant ketamine, but not the delayed-onset antidepressant, venlafaxine, attenuated the previously acquired FG7142-induced negative bias following systemic administration. Venlafaxine but not ketamine induced a positive bias when administered before learning. We then used local drug infusions and excitotoxic lesions to localize the effects of ketamine to the medial prefrontal cortex and venlafaxine to the amygdala. Using a modified protocol we also showed that positive and negative biases amplified further when the numbers of substrate–reinforcer associations are increased. We propose that this pattern of results could explain the delayed onset of action of venlafaxine and the rapid onset of action but lack of long-term efficacy seen with ketamine. PMID:25740288

  2. Rapid Detection of the Chlamydiaceae and Other Families in the Order Chlamydiales: Three PCR Tests

    Science.gov (United States)

    Everett, Karin D. E.; Hornung, Linda J.; Andersen, Arthur A.

    1999-01-01

    Few identification methods will rapidly or specifically detect all bacteria in the order Chlamydiales, family Chlamydiaceae. In this study, three PCR tests based on sequence data from over 48 chlamydial strains were developed for identification of these bacteria. Two tests exclusively recognized the Chlamydiaceae: a multiplex test targeting the ompA gene and the rRNA intergenic spacer and a TaqMan test targeting the 23S ribosomal DNA. The multiplex test was able to detect as few as 200 inclusion-forming units (IFU), while the TaqMan test could detect 2 IFU. The amplicons produced in these tests ranged from 132 to 320 bp in length. The third test, targeting the 23S rRNA gene, produced a 600-bp amplicon from strains belonging to several families in the order Chlamydiales. Direct sequence analysis of this amplicon has facilitated the identification of new chlamydial strains. These three tests permit ready identification of chlamydiae for diagnostic and epidemiologic study. The specificity of these tests indicates that they might also be used to identify chlamydiae without culture or isolation. PMID:9986815

  3. Rapid screening test for gestational diabetes: public health need, market requirement, initial product design, and experimental results

    Science.gov (United States)

    Weigl, Bernhard H.; Zwisler, Greg; Peck, Roger; Abu-Haydar, Elizabeth

    2013-03-01

    Gestational diabetes is a global epidemic where many urban areas in Southeast Asia have found prevalence rates as high as 20%, exceeding the highest prevalence rates in the developed world. It can have serious and life-threatening consequences for mothers and babies. We are developing two variants of a new, simple, low-cost rapid test for screening for gestational diabetes mellitus for use primarily in low-resource settings. The pair of assays, both semiquantitative rapid diagnostic strip tests for glycated albumin, require neither fasting nor an oral glucose challenge test. One variant is an extremely simple strip test to estimate the level of total glycated albumin in blood. The other, which is slightly more complex and expensive, is a test that determines the ratio of glycated albumin to total albumin. The screening results can be used to refer women to receive additional care during delivery to avoid birth complications as well as counseling on diet and exercise during and after pregnancy. Results with the latter test may also be used to start treatment with glucose-lowering drugs. Both assays will be read visually. We present initial results of a preliminary cost-performance comparison model evaluating the proposed test versus existing alternatives. We also evaluated user needs and schematic paper microfluidics-based designs aimed at overcoming the challenge of visualizing relatively narrow differences between normal and elevated levels of glycated albumin in blood.

  4. Incidental learning during rapid information processing on the symbol-digit modalities test.

    Science.gov (United States)

    Denney, Douglas R; Hughes, Abbey J; Elliott, Jacquelyn K; Roth, Alexandra K; Lynch, Sharon G

    2015-06-01

    The Symbol--Digit Modalities Test (SDMT) is widely used to assess processing speed in MS patients. We developed a computerized version of the SDMT (c-SDMT) that scored participants' performance during subintervals over the course of the usual 90-s time period and also added an incidental learning test (c-ILT) to assess how well participants learned the symbol-digit associations while completing the c-SDMT. Patients with MS (n = 65) achieved lower scores than healthy controls (n = 38) on both the c-SDMT and c-ILT, and the scores on the two tests were correlated. However, no increase in the rate of item completion occurred for either group over the course of the c-SDMT, and the difference between groups was the same during each subinterval. Therefore, it seems implausible that controls completed more items on the c-SDMT because they were more adept at learning the symbol-digit associations as the test ensued. Instead, MS patients' poorer incidental learning performance appears to reflect the greater attentional burden that tasks requiring rapid serial processing of information impose upon them. © The Author 2015. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  5. On the Adaptive Design Rules of Biochemical Networks in Evolution

    Directory of Open Access Journals (Sweden)

    Bor-Sen Chen

    2007-01-01

    Full Text Available Biochemical networks are the backbones of physiological systems of organisms. Therefore, a biochemical network should be sufficiently robust (not sensitive to tolerate genetic mutations and environmental changes in the evolutionary process. In this study, based on the robustness and sensitivity criteria of biochemical networks, the adaptive design rules are developed for natural selection in the evolutionary process. This will provide insights into the robust adaptive mechanism of biochemical networks in the evolutionary process. We find that if a mutated biochemical network satisfies the robustness and sensitivity criteria of natural selection, there is a high probability for the biochemical network to prevail during natural selection in the evolutionary process. Since there are various mutated biochemical networks that can satisfy these criteria but have some differences in phenotype, the biochemical networks increase their diversities in the evolutionary process. The robustness of a biochemical network enables co-option so that new phenotypes can be generated in evolution. The proposed robust adaptive design rules of natural selection gain much insight into the evolutionary mechanism and provide a systematic robust biochemical circuit design method of biochemical networks for biotechnological and therapeutic purposes in the future.

  6. Cost-effectiveness analysis of cervical cancer prevention based on a rapid human papillomavirus screening test in a high-risk region of China.

    Science.gov (United States)

    Levin, Carol E; Sellors, John; Shi, Ju-Fang; Ma, Li; Qiao, You-lin; Ortendahl, Jesse; O'Shea, Meredith K H; Goldie, Sue J

    2010-09-01

    This study assessed the cost-effectiveness of a new, rapid human papillomavirus (HPV)-DNA screening test for cervical cancer prevention in the high-risk region of Shanxi, China. Using micro-costing methods, we estimated the resources needed to implement preventive strategies using cervical cytology or HPV-DNA testing, including the Hybrid Capture 2 (hc2) test (QIAGEN Corp., Gaithersburg, MD) and the rapid HPV-DNA careHPV test (QIAGEN). Data were used in a previously published model and empirically calibrated to country-specific epidemiological data. Strategies differed by initial test, targeted age, frequency of screening, number of clinic visits required (1, 2 or 3) and service delivery setting (national, county and township levels). Outcomes included lifetime risk of cancer, years of life saved (YLS), lifetime costs and incremental cost-effectiveness ratios (cost per YLS). For all screening frequencies, the most efficient strategy used 2-visit rapid HPV-DNA testing at the county level, including screening and diagnostics in the first visit, and treatment in the second visit. Screening at ages 35, 40 and 45 reduced cancer risk by 50% among women compliant with all 3 screening rounds, and was US$ 150 per YLS, compared with this same strategy applied twice per lifetime. This would be considered very cost-effective evaluated against China's per-capita gross domestic product (US$ 1,702). By enhancing the linkage between screening and treatment through a reduced number of visits, rapid HPV-DNA testing 3 times per lifetime is more effective than traditional cytology, and is likely to be cost-effective in high-risk regions of China.

  7. Raman spectroscopic biochemical mapping of tissues

    Science.gov (United States)

    Stone, Nicholas; Hart Prieto, Maria C.; Kendall, Catherine A.; Shetty, Geeta; Barr, Hugh

    2006-02-01

    Advances in technologies have brought us closer to routine spectroscopic diagnosis of early malignant disease. However, there is still a poor understanding of the carcinogenesis process. For example it is not known whether many cancers follow a logical sequence from dysplasia, to carcinoma in situ, to invasion. Biochemical tissue changes, triggered by genetic mutations, precede morphological and structural changes. These can be probed using Raman or FTIR microspectroscopy and the spectra analysed for biochemical constituents. Local microscopic distribution of various constituents can then be visualised. Raman mapping has been performed on a number of tissues including oesophagus, breast, bladder and prostate. The biochemical constituents have been calculated at each point using basis spectra and least squares analysis. The residual of the least squares fit indicates any unfit spectral components. The biochemical distribution will be compared with the defined histopathological boundaries. The distribution of nucleic acids, glycogen, actin, collagen I, III, IV, lipids and others appear to follow expected patterns.

  8. Laboratory Diagnosis and Susceptibility Testing for Mycobacterium tuberculosis.

    Science.gov (United States)

    Procop, Gary W

    2016-12-01

    The laboratory, which utilizes some of the most sophisticated and rapidly changing technologies, plays a critical role in the diagnosis of tuberculosis. Some of these tools are being employed in resource-challenged countries for the rapid detection and characterization of Mycobacterium tuberculosis. Foremost, the laboratory defines appropriate specimen criteria for optimal test performance. The direct detection of mycobacteria in the clinical specimen, predominantly done by acid-fast staining, may eventually be replaced by rapid-cycle PCR. The widespread use of the Xpert MTB/RIF (Cepheid) assay, which detects both M. tuberculosis and key genetic determinants of rifampin resistance, is important for the early detection of multidrug-resistant strains. Culture, using both broth and solid media, remains the standard for establishing the laboratory-based diagnosis of tuberculosis. Cultured isolates are identified far less commonly by traditional biochemical profiling and more commonly by molecular methods, such as DNA probes and broad-range PCR with DNA sequencing. Non-nucleic acid-based methods of identification, such as high-performance liquid chromatography and, more recently, matrix-assisted laser desorption/ionization-time of flight mass spectrometry, may also be used for identification. Cultured isolates of M. tuberculosis should be submitted for susceptibility testing according to standard guidelines. The use of broth-based susceptibility testing is recommended to significantly decrease the time to result. Cultured isolates may also be submitted for strain typing for epidemiologic purposes. The use of massive parallel sequencing, also known as next-generation sequencing, promises to continue to this molecular revolution in mycobacteriology, as whole-genome sequencing provides identification, susceptibility, and typing information simultaneously.

  9. Diagnostic performance of a rapid in-clinic test for the detection of Canine Parvovirus under different storage conditions and vaccination status.

    Science.gov (United States)

    Kantere, Maria C; Athanasiou, Labrini V; Spyrou, Vassiliki; Kyriakis, Constantinos S; Kontos, Vassilios; Chatzopoulos, Dimitrios C; Tsokana, Constantina N; Billinis, Charalambos

    2015-04-01

    Canine parvovirus (CPV) is one of the most common causes of acute haemorrhagic enteritis in young dogs, while clinical diagnosis is often indecisive. The aim of our study was to evaluate the diagnostic accuracy of an in-clinic rapid test in the detection of CPV infection in dogs. To this end, we compared the Rapid Diagnostic Kit of Canine Parvovirus, Coronavirus and Rotavirus antigen (Quicking(®)) to PCR, which is considered as the most reliable diagnostic method. A total of 78 duplicated faecal samples were collected from diarrhoeic dogs. Vaccination history within a month prior to the onset of diarrhoea was reported for 12 of the sampled dogs. The rapid diagnostic test was performed in 23 of the faecal samples directly, while the rest were placed into a sterile cotton tipped swab suitable for collection and transportation of viruses (Sigma Σ-VCM(®)) and stored at -20 °C. The sensitivity of the Quicking rapid diagnostic test compared to PCR in the total number of samples, in samples from non-vaccinated dogs and in samples tested directly after collection were 22.22% (95% CI: 13.27-33.57%), 26.67% (95% CI: 16.08-39.66%) and 76.47% (95% CI: 50.10-93.04%) respectively, while the specificity of the test was 100% in any case. In conclusion, negative results do not exclude parvoenteritis from the differential diagnosis, especially in dogs with early vaccination history, but a positive result almost certainly indicates CPV infection. An improved sensitivity may be expected when the test is performed immediately. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Detection of helicobacter pylori in nasal polyps using rapid urease test and ELISA

    Directory of Open Access Journals (Sweden)

    Masood Kaviani

    2009-01-01

    Full Text Available Introduction: Nasal polyposis is an inflammatory condition of unknown etiology. Recently concerns regarding gastroesophageal reflux or helicobacter pylori as a possible pathologic cause of nasal polyps have been increasing. The present study was planned to investigate the presence of helicobacter pylori in nasal polyps. Materials and Methods: This case-control study was undertaken enrolling 37 patients with nasal polyps who had undergone nasal endoscopic sinus surgery and 38 control subjects. Biopsy specimens of nasal polyps and inferior turbinates were assessed by rapid urease test. Blood samples of both study and control subjects were evaluated for anti H.pylori IgG by ELISA. H. pylori status was regarded positive, if both tests were positive. Results: Seropositivity was more common in the patients with nasal polyps (66.2% than control subjects (36.8% (P

  11. Simulation studies in biochemical signaling and enzyme reactions

    Science.gov (United States)

    Nelatury, Sudarshan R.; Vagula, Mary C.

    2014-06-01

    Biochemical pathways characterize various biochemical reaction schemes that involve a set of species and the manner in which they are connected. Determination of schematics that represent these pathways is an important task in understanding metabolism and signal transduction. Examples of these Pathways are: DNA and protein synthesis, and production of several macro-molecules essential for cell survival. A sustained feedback mechanism arises in gene expression and production of mRNA that lead to protein synthesis if the protein so synthesized serves as a transcription factor and becomes a repressor of the gene expression. The cellular regulations are carried out through biochemical networks consisting of reactions and regulatory proteins. Systems biology is a relatively new area that attempts to describe the biochemical pathways analytically and develop reliable mathematical models for the pathways. A complete understanding of chemical reaction kinetics is prohibitively hard thanks to the nonlinear and highly complex mechanisms that regulate protein formation, but attempting to numerically solve some of the governing differential equations seems to offer significant insight about their biochemical picture. To validate these models, one can perform simple experiments in the lab. This paper introduces fundamental ideas in biochemical signaling and attempts to take first steps into the understanding of biochemical oscillations. Initially, the two-pool model of calcium is used to describe the dynamics behind the oscillations. Later we present some elementary results showing biochemical oscillations arising from solving differential equations of Elowitz and Leibler using MATLAB software.

  12. Buffer substitution in malaria rapid diagnostic tests causes false-positive results

    Directory of Open Access Journals (Sweden)

    Van den Ende Jef

    2010-07-01

    Full Text Available Abstract Background Malaria rapid diagnostic tests (RDTs are kits that generally include 20 to 25 test strips or cassettes, but only a single buffer vial. In field settings, laboratory staff occasionally uses saline, distilled water (liquids for parenteral drugs dilution or tap water as substitutes for the RDT kit's buffer to compensate for the loss of a diluent bottle. The present study assessed the effect of buffer substitution on the RDT results. Methods Twenty-seven RDT brands were run with EDTA-blood samples of five malaria-free subjects, who were negative for rheumatoid factor and antinuclear antibodies. Saline, distilled water and tap water were used as substitute liquids. RDTs were also run with distilled water, without adding blood. Results were compared to those obtained with the RDT kit's buffer and Plasmodium positive samples. Results Only eight cassettes (in four RDT brands showed no control line and were considered invalid. Visible test lines occurred for at least one malaria-free sample and one of the substitutes in 20/27 (74% RDT brands (saline: n = 16; distilled water: n = 17; and tap water: n = 20, and in 15 RDTs which were run with distilled water only. They occurred for all Plasmodium antigens and RDT formats (two-, three- and four-band RDTs. Clearance of the background of the strip was excellent except for saline. The aspects (colour, intensity and crispness of the control and the false-positive test lines were similar to those obtained with the RDT kits' buffer and Plasmodium positive samples. Conclusion Replacement of the RDT kit's dedicated buffer by saline, distilled water and tap water can cause false-positive test results.

  13. Lack of HIV infection among truck drivers in Iran using rapid HIV test

    Directory of Open Access Journals (Sweden)

    Hossain Jabbari

    2010-01-01

    Full Text Available Background: The aim of this study was to evaluate the prevalence of HIV infection in Iranian long distance truck drivers using rapid HIV test. Methods: The study included 400 consecutive participants in Bazargan city, north-west of Iran in the late 2008 and the early 2009. Results: No HIV infection was observed among these long distance truck drivers. Conclusions: Although results of this study is plausible compared to other similar studies, repeated surveys are necessary to know the trend of HIV infection in truckers in Iran.

  14. Feasibility of biochemical verification in a web-based smoking cessation study.

    Science.gov (United States)

    Cha, Sarah; Ganz, Ollie; Cohn, Amy M; Ehlke, Sarah J; Graham, Amanda L

    2017-10-01

    Cogent arguments have been made against the need for biochemical verification in population-based studies with low-demand characteristics. Despite this fact, studies involving digital interventions (low-demand) are often required in peer review to report biochemically verified abstinence. To address this discrepancy, we examined the feasibility and costs of biochemical verification in a web-based study conducted with a national sample. Participants were 600U.S. adult current smokers who registered on a web-based smoking cessation program and completed surveys at baseline and 3months. Saliva sampling kits were sent to participants who reported 7-day abstinence at 3months, and analyzed for cotinine. The response rate at 3-months was 41.2% (n=247): 93 participants reported 7-day abstinence (38%) and were mailed a saliva kit (71% returned). The discordance rate was 36.4%. Participants with discordant responses were more likely to report 3-month use of nicotine replacement therapy or e-cigarettes than those with concordant responses (79.2% vs. 45.2%, p=0.007). The total cost of saliva sampling was $8280 ($125/sample). Biochemical verification was both time- and cost-intensive, and yielded a relatively small number of samples due to low response rates and use of other nicotine products during the follow-up period. There was a high rate of discordance of self-reported abstinence and saliva testing. Costs for data collection may be prohibitive for studies with large sample sizes or limited budgets. Our findings echo previous statements that biochemical verification is not necessary in population-based studies, and add evidence specific to technology-based studies. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Field Testing of Rapid Electrokinetic Nanoparticle Treatment for Corrosion Control of Steel in Concrete

    Science.gov (United States)

    Cardenas, Henry E.; Alexander, Joshua B.; Kupwade-Patil,Kunal; Calle, Luz Marina

    2009-01-01

    This work field tested the use of electrokinetics for delivery of concrete sealing nanoparticles concurrent with the extraction of chlorides. Several cylinders of concrete were batched and placed in immersion at the Kennedy Space Center Beach Corrosion Test Site. The specimens were batched with steel reinforcement and a 4.5 wt.% (weight percent) content of sodium chloride. Upon arrival at Kennedy Space Center, the specimens were placed in the saltwater immersion pool at the Beach Corrosion Test Site. Following 30 days of saltwater exposure, the specimens were subjected to rapid chloride extraction concurrent with electrokinetic nanoparticle treatment. The treatments were operated at up to eight times the typical current density in order to complete the treatment in 7 days. The findings indicated that the short-term corrosion resistance of the concrete specimens was significantly enhanced as was the strength of the concrete.

  16. Computer-facilitated rapid HIV testing in emergency care settings: provider and patient usability and acceptability.

    Science.gov (United States)

    Spielberg, Freya; Kurth, Ann E; Severynen, Anneleen; Hsieh, Yu-Hsiang; Moring-Parris, Daniel; Mackenzie, Sara; Rothman, Richard

    2011-06-01

    Providers in emergency care settings (ECSs) often face barriers to expanded HIV testing. We undertook formative research to understand the potential utility of a computer tool, "CARE," to facilitate rapid HIV testing in ECSs. Computer tool usability and acceptability were assessed among 35 adult patients, and provider focus groups were held, in two ECSs in Washington State and Maryland. The computer tool was usable by patients of varying computer literacy. Patients appreciated the tool's privacy and lack of judgment and their ability to reflect on HIV risks and create risk reduction plans. Staff voiced concerns regarding ECS-based HIV testing generally, including resources for follow-up of newly diagnosed people. Computer-delivered HIV testing support was acceptable and usable among low-literacy populations in two ECSs. Such tools may help circumvent some practical barriers associated with routine HIV testing in busy settings though linkages to care will still be needed.

  17. Research advance in rapid detection of foodborne Staphylococcus aureus

    Directory of Open Access Journals (Sweden)

    Xihong Zhao

    2016-09-01

    Full Text Available Staphylococcus aureus is a gram-positive, coccus-shaped facultative anaerobe and a member of the Staphylococcaceae family. In recent years, alimentary toxicosis caused by S. aureus is a very serious problem worldwide, which constitutes a great threat to public health. In this review, we tried to summarize the conventional methods and newly developed rapid detection techniques of S. aureus (traditional detection method, biochemical detection, immunology method, molecular biology, and biosensor method for their principles, advantages, disadvantages, and applications. Furthermore, the future perspectives of S. aureus detection methods were forecasted at last.

  18. Water stress and recovery in the performance of two Eucalyptus globulus clones: physiological and biochemical profiles.

    Science.gov (United States)

    Correia, Barbara; Pintó-Marijuan, Marta; Neves, Lucinda; Brossa, Ricard; Dias, Maria Celeste; Costa, Armando; Castro, Bruno B; Araújo, Clara; Santos, Conceição; Chaves, Maria Manuela; Pinto, Glória

    2014-04-01

    Eucalyptus plantations are among the most productive forest stands in Portugal and Spain, being mostly used for pulp production and, more recently, as an energy crop. However, the region's Mediterranean climate, with characteristic severe summer drought, negatively affects eucalypt growth and increases mortality. Although the physiological response to water shortage is well characterized for this species, evidence about the plants' recovery ability remains scarce. In order to assess the physiological and biochemical response of Eucalyptus globulus during the recovery phase, two genotypes (AL-18 and AL-10) were submitted to a 3-week water stress period at two different intensities (18 and 25% of field capacity), followed by 1 week of rewatering. Recovery was assessed 1 day and 1 week after rehydration. Drought reduced height, biomass, water potential, NPQ and gas exchange in both genotypes. Contrarily, the levels of pigments, chlorophyll fluorescence parameters (F(v) /F(m) and (φPSII)), MDA and ABA increased. During recovery, the physiological and biochemical profile of stressed plants showed a similar trend: they experienced reversion of altered traits (MDA, ABA, E, g(s), pigments), while other parameters did not recover ((φPSII), NPQ). Furthermore, an overcompensation of CO(2) assimilation was achieved 1 week after rehydration, which was accompanied by greater growth and re-establishment of oxidative balance. Both genotypes were tolerant to the tested conditions, although clonal differences were found. AL-10 was more productive and showed a more rapid and dynamic response to rehydration (namely in carotenoid content, (φPSII) and NPQ) compared to clone AL-18. © 2013 Scandinavian Plant Physiology Society.

  19. Rapid identification and antimicrobial susceptibility testing of positive blood cultures using MALDI-TOF MS and a modification of the standardised disc diffusion test: a pilot study.

    LENUS (Irish Health Repository)

    Fitzgerald, C

    2016-04-27

    In an era when clinical microbiology laboratories are under increasing financial pressure, there is a need for inexpensive, yet effective, rapid microbiology tests. The aim of this study was to evaluate a novel modification of standard methodology for the identification and antimicrobial susceptibility testing (AST) of pathogens in positive blood cultures, reducing the turnaround time of laboratory results by 24 h.

  20. Loop-mediated isothermal amplification (LAMP) test for specific and rapid detection of Brucella abortus in cattle.

    Science.gov (United States)

    Karthik, K; Rathore, Rajesh; Thomas, Prasad; Arun, T R; Viswas, K N; Agarwal, R K; Manjunathachar, H V; Dhama, Kuldeep

    2014-01-01

    Brucella abortus, the major causative agent of abortion in cattle and a zoonotic pathogen, needs to be diagnosed at an early stage. Loop-mediated isothermal amplification (LAMP) test is easy to perform and also promising to be adapted at field level. To develop a LAMP assay for specific and rapid detection of B. abortus from clinical samples of cattle. LAMP primers were designed targeting BruAb2_0168 region using specific software tool and LAMP was optimized. The developed LAMP was tested for its specificity with 3 Brucella spp. and 11 other non-Brucella spp. Sensitivity of the developed LAMP was also carried out with known quantity of DNA. Cattle whole blood samples and aborted fetal stomach contents were collected and used for testing with developed LAMP assay and results were compared with polymerase chain reaction (PCR). The developed LAMP assay works at 61 °C for 60 min and the detection limit was observed to be 100-fold more than the conventional PCR that is commonly used for diagnosis of B. abortus. Clinical sensitivity and specificity of the developed LAMP assay was 100% when compared with Rose Bengal plate test and standard tube agglutination test. SYB® green dye I was used to visualize the result with naked eye. The novelty of the developed LAMP assay for specifically detecting B. abortus infection in cattle along with its inherent rapidness and high sensitivity can be employed for detecting this economically important pathogen of cattle at field level as well be exploited for screening of human infections.

  1. A Review on the Role of Vibrational Spectroscopy as An Analytical Method to Measure Starch Biochemical and Biophysical Properties in Cereals and Starchy Foods

    Directory of Open Access Journals (Sweden)

    D. Cozzolino

    2014-12-01

    Full Text Available Starch is the major component of cereal grains and starchy foods, and changes in its biophysical and biochemical properties (e.g., amylose, amylopectin, pasting, gelatinization, viscosity will have a direct effect on its end use properties (e.g., bread, malt, polymers. The use of rapid and non-destructive methods to study and monitor starch properties, such as gelatinization, retrogradation, water absorption in cereals and starchy foods, is of great interest in order to improve and assess their quality. In recent years, near infrared reflectance (NIR and mid infrared (MIR spectroscopy have been explored to predict several quality parameters, such as those generated by instrumental methods commonly used in routine analysis like the rapid visco analyser (RVA or viscometers. In this review, applications of both NIR and MIR spectroscopy to measure and monitor starch biochemical (amylose, amylopectin, starch and biophysical properties (e.g., pasting properties will be presented and discussed.

  2. Developing and Validating a Rapid Small-Scale Column Test Procedure for GAC Selection using Reconstituted Lyophilized NOM

    Science.gov (United States)

    Cost effective design and operation of Granular Activated Carbon (GAC) facilities requires the selection of GAC that is optimal for a specific site. Rapid small-scale column tests (RSSCTs) are widely used for GAC assessment due to several advantages, including the ability to simu...

  3. HIV rapid diagnostic testing by lay providers in a key population-led health service programme in Thailand.

    Science.gov (United States)

    Wongkanya, Rapeeporn; Pankam, Tippawan; Wolf, Shauna; Pattanachaiwit, Supanit; Jantarapakde, Jureeporn; Pengnongyang, Supabhorn; Thapwong, Prasopsuk; Udomjirasirichot, Apichat; Churattanakraisri, Yutthana; Prawepray, Nanthika; Paksornsit, Apiluk; Sitthipau, Thidadaow; Petchaithong, Sarayut; Jitsakulchaidejt, Raruay; Nookhai, Somboon; Lertpiriyasuwat, Cheewanan; Ongwandee, Sumet; Phanuphak, Praphan; Phanuphak, Nittaya

    2018-01-01

    Introduction:  Rapid diagnostic testing (RDT) for HIV has a quick turn-around time, which increases the proportion of people testing who receive their result. HIV RDT in Thailand has traditionally been performed only by medical technologists (MTs), which is a barrier to its being scaled up. We evaluated the performance of HIV RDT conducted by trained lay providers who were members of, or worked closely with, a group of men who have sex with men (MSM) and with transgender women (TG) communities, and compared it to tests conducted by MTs. Methods:  Lay providers received a 3-day intensive training course on how to perform a finger-prick blood collection and an HIV RDT as part of the Key Population-led Health Services (KPLHS) programme among MSM and TG. All the samples were tested by lay providers using Alere Determine HIV 1/2. HIV-reactive samples were confirmed by DoubleCheckGold Ultra HIV 1&2 and SD Bioline HIV 1/2. All HIV-positive and 10% of HIV-negative samples were re-tested by MTs using Serodia HIV 1/2. Results:  Of 1680 finger-prick blood samples collected and tested using HIV RDT by lay providers in six drop-in centres in Bangkok, Chiang Mai, Chonburi and Songkhla, 252 (15%) were HIV-positive. MTs re-tested these HIV-positive samples and 143 randomly selected HIV-negative samples with 100% concordant test results. Conclusion:  Lay providers in Thailand can be trained and empowered to perform HIV RDT as they were found to achieve comparable results in sample testing with MTs. Based on the task-shifting concept, this rapid HIV testing performed by lay providers as part of the KPLHS programme has great potential to enhance HIV prevention and treatment programmes among key at-risk populations.

  4. [Role of angiotensin II receptor type 2 in predicting biochemical recurrence in the treatment of prostate cancer].

    Science.gov (United States)

    Chibichyan, M B; Kogan, M I; Chernogubova, E A; Pavlenko, I A; Matishov, D G

    2016-12-01

    To identify markers for predicting aggressive forms of prostate cancer. The study retrospectively evaluated expression of angiotensin II type 2 receptors (AT2-R) in prostate needle biopsy tissue from patients with and without biochemical recurrence after combined hormone and radiation therapy. The study findings showed that low expression of AT2-R in prostate tissue was associated with a high risk of biochemical recurrence. The data on the nature of AT2-R expression in prostate tissue of prostate cancer patients may be considered as a tool for predicting biochemical recurrence after combined hormone and radiation therapy. The test has a sensitivity of 87.5% and specificity of 85.71%.

  5. A systematic review of the clinical, public health and cost-effectiveness of rapid diagnostic tests for the detection and identification of bacterial intestinal pathogens in faeces and food.

    Science.gov (United States)

    Abubakar, I; Irvine, L; Aldus, C F; Wyatt, G M; Fordham, R; Schelenz, S; Shepstone, L; Howe, A; Peck, M; Hunter, P R

    2007-09-01

    To determine the diagnostic accuracy of tests for the rapid diagnosis of bacterial food poisoning in clinical and public health practice and to estimate the cost-effectiveness of these assays in a hypothetical population in order to inform policy on the use of these tests. Studies evaluating diagnostic accuracy of rapid tests were retrieved using electronic databases and handsearching reference lists and key journals. Hospital laboratories and test manufacturers were contacted for cost data, and clinicians involved in the care of patients with food poisoning were invited to discuss the conclusions of this review using the nominal group technique. A systematic review of the current medical literature on assays used for the rapid diagnosis of bacterial food poisoning was carried out. Specific organisms under review were Salmonella, Campylobacter, Escherichia coli O157, Staphylococcus aureus, Clostridium perfringens and Bacillus cereus. Data extraction was undertaken using standardised data extraction forms. Where a sufficient number of studies evaluating comparable tests were identified, meta-analysis was performed. A decision analytic model was developed, using effectiveness data from the review and cost data from hospitals and manufacturers, which contributed to an assessment of the cost-effectiveness of rapid tests in a hypothetical UK population. Finally, diagnostic accuracy and cost-effectiveness results were presented to a focus group of GPs, microbiologists and consultants in communicable disease control, to assess professional opinion on the use of rapid tests in the diagnosis of food poisoning. Good test performance levels were observed with rapid test methods, especially for polymerase chain reaction (PCR) assays. The estimated levels of diagnostic accuracy using the area under the curve of the summary receiver operating characteristic curve was very high. Indeed, although traditional culture is the natural reference test to use for comparative statistical

  6. Rapid detection of fumonisin B1 using a colloidal gold immunoassay strip test in corn samples.

    Science.gov (United States)

    Ling, Sumei; Wang, Rongzhi; Gu, Xiaosong; Wen, Can; Chen, Lingling; Chen, Zhibin; Chen, Qing-Ai; Xiao, Shiwei; Yang, Yanling; Zhuang, Zhenhong; Wang, Shihua

    2015-12-15

    Fumonisin B1 (FB1) is the most common and highest toxic of fumonisins species, exists frequently in corn and corn-based foods, leading to several animal and human diseases. Furthermore, FB1 was reported that it was associated with the human esophageal cancer. In view of the harmful of FB1, it is urgent to develop a feasible and accuracy method for rapid detection of FB1. In this study, a competitive immunoassay for FB1 detection was developed based on colloidal gold-antibody conjugate. The FB1-keyhole limpet hemoeyanin (FB1-KLH) conjugate was embedded in the test line, and goat anti-mouse IgG antibody embedded in the control line. The color density of the test line correlated with the concentration of FB1 in the range from 2.5 to 10 ng/mL, and the visual limit detection of test for FB1 was 2.5 ng/mL. The results indicated that the test strip is specific for FB1, and no cross-reactivity to other toxins. The quantitative detection for FB1 was simple, only needing one step without complicated assay performance and expensive equipment, and the total time of visual evaluation was less than 5 min. Hence, the developed colloidal gold-antibody assay can be used as a feasible method for FB1 rapid and quantitative detection in corn samples. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Hepatitis B virus surface antigen and anti-hepatitis C virus rapid tests underestimate hepatitis prevalence among HIV-infected patients

    DEFF Research Database (Denmark)

    Hønge, Bo Langhoff; Jespersen, S; Medina, C

    2014-01-01

    . RESULTS: Two rapid tests were used in Guinea-Bissau: HBsAg Strip Ref 2034 (VEDA.LAB, Alençon, France; sensitivity 62.3%; specificity 99.2%) and HEPA-SCAN (Bhat Bio-Tech, Bangalore, India; sensitivity 57.1%; specificity 99.7%). In the two tests the ability to obtain the correct outcome depended...

  8. Rapid aneuploidy testing (knowing less) versus traditional karyotyping (knowing more) for advanced maternal age: what would be missed, who should decide?

    Science.gov (United States)

    Leung, W C; Lau, E T; Lau, W L; Tang, Rebecca; Wong, Shell Fean; Lau, T K; Tse, K T; Wong, S F; To, W K; Ng, Lucy K L; Lao, T T; Tang, Mary H Y

    2008-02-01

    The application of rapid aneuploidy testing as a stand-alone approach in prenatal diagnosis is much debated. The major criticism of this targeted approach is that it will not detect other chromosomal abnormalities that will be picked up by traditional karyotyping. This study aimed to study the nature of such chromosomal abnormalities and whether parents would choose to terminate affected pregnancies. Retrospective study on a cytogenetic database. Eight public hospitals in Hong Kong. The karyotype results of 19 517 amniotic fluid cultures performed for advanced maternal age (>or=35 years) from 1997 to 2002 were classified according to whether they were detectable by rapid aneuploidy testing. The outcomes of pregnancies with abnormal karyotypes were reviewed from patient records. In all, 333 (1.7%) amniotic fluid cultures yielded abnormal karyotypes; 175 (52.6%) of these were detected by rapid aneuploidy testing, and included trisomy 21 (n=94, 28.2%), trisomy 18 or 13 (n=21, 6.3%), and sex chromosome abnormalities (n=60, 18.0%). The other 158 (47.4%) chromosomal abnormalities were not detectable by rapid aneuploidy testing, of which 63 (18.9%) were regarded to be of potential clinical significance and 95 (28.5%) of no clinical significance. Pregnancy outcomes in 327/333 (98.2%) of these patients were retrieved. In total, 143 (42.9%) of these pregnancies were terminated: 93/94 (98.9%) for trisomy 21, 20/21 (95.2%) for trisomy 18 or 13, 19/60 (31.7%) for sex chromosome abnormalities, and 11/63 (17.5%) for other chromosomal abnormalities with potential clinical significance. There were no terminations in the 95 pregnancies in which karyotyping results were regarded to be of no clinical significance. 'Knowing less' by the rapid aneuploidy stand-alone testing could miss about half of all chromosomal abnormalities detectable by amniocentesis performed for advanced maternal age. Findings from two fifths of the latter were of potential clinical significance, and the parents

  9. Characterization of some Brucella species from Zimbabwe by biochemical profiling and AMOS-PCR

    Directory of Open Access Journals (Sweden)

    Skjerve Eystein

    2009-12-01

    Full Text Available Abstract Background Bovine brucellosis caused by Brucella abortus is endemic in most large commercial and smallholder cattle farms of Zimbabwe, while brucellosis in other domestic animals is rare. The diagnosis of brucellosis is mainly accomplished using serological tests. However, some Brucella spp. have been isolated from clinical cases in the field and kept in culture collection but their biochemical profiles were not documented. We report biochemical profiling and AMOS-PCR characterization of some of these field isolates of Brucella originating from both commercial and smallholder cattle farming sectors of Zimbabwe. Findings Fourteen isolates of Brucella from culture collection were typed using biochemical profiles, agglutination by monospecific antisera, susceptibility to Brucella-specific bacteriophages and by AMOS-PCR that amplifies species- specific IS711. The results of the biochemical profiles for B. abortus biovar 1 (11 isolates and biovar 2 (2 isolates were consistent with those of reference strains. A single isolate from a goat originating from a smallholder mixed animal farm was identified as B. melitensis biovar 1. The AMOS-PCR produced DNA products of sizes 498 bp and 731 bp for B. abortus (biovar 1 and 2 and B. melitensis biovar 1, respectively. Conclusion We concluded that the biochemical profiles and AMOS-PCR characterization were consistent with their respective species and biovars. B. abortus biovar 1 is likely to be the predominant cause of brucellosis in both commercial and smallholder cattle farms in Zimbabwe.

  10. Biochemical and hematological findings of Khorasan veterans 23 years after sulfur mustard exposure

    Directory of Open Access Journals (Sweden)

    Mohammad Reza Keramati

    2013-01-01

    Full Text Available Background: Sulfur mustard (SM is an incapacitating chemical warfare agent, which has been widely employed in particular regions including Iran. We investigated and reported delayed biochemical and hematological complications of SM in severely toxic Iranian veterans 23 years after exposure. Materials and Methods : Forty-two Iranian veterans, residents of Khorasan Razavi, poisoned by SM, and suffering from clinical complications were investigated. A total of 30 healthy male volunteers were also selected as a control group. Biochemical and hematological variables were measured for the case and control groups. Data were analyzed using a Student′s t-test by InStat software (GraphPad Inc., San Diego, CA to determine significant differences between the data from the two groups. Results: The percentages of reticulocytes were significantly higher in patients (0.82 ± 0.04, P < 0.05. Total protein and albumin levels were significantly lower in veterans (total protein: 7.58 ± 0.07 g/dL, albumin: 4.97 ± 0.04 g/dL, P < 0.01. In addition, we observed a significant increase in serum cholesterol (226.74 ± 5.23 mg/dL, P < 0.01, triglyceride (173.53 ± 17.05 mg/dL, P < 0.05, and gamma-glutamyl transferase (GTT activity of the patients (44.04 ± 3.35 IU/L, P < 0.05. Conclusion: Results showed that SM can cause long-term effects on some biochemical factors of veterans. As many of the functional tests of liver and kidney between two groups were statistically unchanged, it seems that the observed biochemical changes may be secondary to delayed respiratory complications of the patients.

  11. The Influence of Biochemical Modification on the Properties of Adhesive Compounds

    OpenAIRE

    Anna Rudawska; Izabela Haniecka; Magdalena Jaszek; Monika Osińska-Jaroszuk

    2016-01-01

    The main objective of this study was to determine the effect of biochemical modification of epoxy adhesive compounds on the mechanical properties of a cured adhesive exposed to various climatic factors. The epoxy adhesive was modified by lyophilized fungal metabolites and prepared by three methods. Additionally, the adhesive compound specimens were seasoned for two months at a temperature of 50 °C and 50% humidity in a climate test chamber, Espec SH 661. The tensile strength tests of the adh...

  12. Biochemical Process Development and Integration | Bioenergy | NREL

    Science.gov (United States)

    Biochemical Process Development and Integration Biochemical Process Development and Integration Our conversion and separation processes to pilot-scale integrated process development and scale up. We also Publications Accounting for all sugar produced during integrated production of ethanol from lignocellulosic

  13. Has introduction of rapid drug susceptibility testing at diagnosis impacted treatment outcomes among previously treated tuberculosis patients in Gujarat, India?

    Directory of Open Access Journals (Sweden)

    Paresh Dave

    Full Text Available Revised National TB Control Programme (RNTCP in India recommends that all previously-treated TB (PT patients are offered drug susceptibility testing (DST at diagnosis, using rapid diagnostics and screened out for rifampicin resistance before being treated with standardized, eight-month, retreatment regimen. This is intended to improve the early diagnosis of rifampicin resistance and its appropriate management and improve the treatment outcomes among the rest of the patients. In this state-wide study from Gujarat, India, we assess proportion of PT patients underwent rapid DST at diagnosis and the impact of this intervention on their treatment outcomes.This is a retrospective cohort study involving review of electronic patient-records maintained routinely under RNTCP. All PT patients registered for treatment in Gujarat during January-June 2013 were included. Information on DST and treatment outcomes were extracted from 'presumptive DR-TB patient register' and TB treatment register respectively. We performed a multivariate analysis to assess if getting tested is independently associated with unfavourable outcomes (death, loss-to-follow-up, failure, transfer out.Of 5,829 PT patients, 5306(91% were tested for drug susceptibility with rapid diagnostics. Overall, 71% (4,113 TB patients were successfully treated - 72% among tested versus 60% among non-tested. Patients who did not get tested at diagnosis had a 34% higher risk of unsuccessful outcomes as compared to those who got tested (aRR - 1.34; 95% CI 1.20-1.50 after adjusting for age, sex, HIV status and type of TB. Unfavourable outcomes (particularly failure and switched to category IV were higher among INH-resistant patients (39% as compared to INH-sensitive (29%.Offering DST at diagnosis improved the treatment outcomes among PT patients. However, even among tested, treatment outcomes remained suboptimal and were related to INH resistance and high loss-to-follow-up. These need to be addressed

  14. Hydrogenation of rapeseed oil for production of liquid bio-chemicals

    International Nuclear Information System (INIS)

    Pinto, F.; Martins, S.; Gonçalves, M.; Costa, P.; Gulyurtlu, I.; Alves, A.; Mendes, B.

    2013-01-01

    Highlights: ► Production of renewable liquid hydrocarbons through rapeseed oil hydrogenation. ► Hydrogenation at lower temperature and lower hydrogen pressures. ► Test of a catalyst commonly employed in petrochemical industry. ► Improve of hydrogenation process viability by decreasing operational costs. ► Analysis of hydrogenated product applications as bio-chemicals. -- Abstract: The main objective of rapeseed oil hydrogenation tests was the production of liquid bio-chemicals to be used as renewable raw material for the production of several chemicals and in chemical synthesis to substitute petroleum derived stuff. As, hydrogenation of vegetable oils is already applied for the production of biofuels, the work done focused in producing aromatic compounds, due to their economic value. The effect of experimental conditions on rapeseed oil hydrogenation was studied, namely, reaction temperature and time with the aim of selecting the most favourable conditions to convert rapeseed oil into liquid valuable bio-chemicals. Rapeseed oil was hydrogenated at a hydrogen initial pressure of 1.10 MPa. Reaction temperature varied in the range from 200 °C to 400 °C, while reaction times between 6 and 180 min were tested. The performance of a commercial cobalt and molybdenum catalyst was also studied. The highest hydrocarbons yields were obtained at the highest temperature and reaction times tested. At a temperature of 400 °C and at the reaction time of 120 min hydrocarbons yield was about 92% in catalyst presence, while in the absence of the catalyst this value decreased to 85%. Hydrocarbons yield was even higher when the reaction time of 180 min was used in the presence of catalyst, as the yield of 97% was observed. At these conditions hydrocarbons formed had a high content of aromatic compounds, around 50%. For this reason, the viscosity values of hydrogenated oils were lower than that established by EN590, which together with hydrogenated liquids composition

  15. Microbiological characteristics of subgingival microbiota in adult periodontitis, localized juvenile periodontitis and rapidly progressive periodontitis subjects.

    Science.gov (United States)

    Nonnenmacher, C; Mutters, R; de Jacoby, L F

    2001-04-01

    To describe the prevalence of the cultivable subgingival microbiota in periodontal diseases and to draw attention to the polymicrobial nature of periodontic infections. The study population consisted of 95 patients, 51 females and 44 males, aged 14-62 years. Twenty-nine patients exhibited adult periodontitis (AP), six localized juvenile periodontitis (LJP), and 60 rapidly progressive periodontitis (RPP). Two to four pooled bacterial samples were obtained from each patient. Samples were collected with sterile paper points from the deepest periodontal pockets. The samples were cultured under anaerobic and microaerophilic conditions using selective and non-selective media. Isolates were characterized to species level by conventional biochemical tests and by a commercial rapid test system. Prevotella intermedia and Capnocytophaga spp. were the most frequently detected microorganisms in all diagnostic groups. Porphyromonas gingivalis and Peptostreptococcus micros were found more frequently in AP and RPP patients, while Actinobacillus actinomycetemcomitans and Eikenella corrodens were associated with AP, LJP and RPP patients. The other bacterial species, including Actinomyces spp., Streptococcus spp. and Eubacterium spp., were detected at different levels in the three disease groups. The data show the complexity of the subgingival microbiota associated with different periodontal disease groups, indicating that the detection frequency and levels of recovery of some periodontal pathogens are different in teeth affected by different forms of periodontal disease.

  16. Smoke produced from plants waste material elicits growth of wheat (Triticum aestivum L. by improving morphological, physiological and biochemical activity

    Directory of Open Access Journals (Sweden)

    Muhammad Iqbal

    2018-03-01

    Full Text Available The experimental work presented in this study was carried out with the hypothesis that plant derived smoke enhanced the morphological, physiological and biochemical attributes of a cereal crop, wheat (Triticum aestivum L.. Furthermore, this study supported the hypothesis that plant derived smoke acts as vegetative growth promoter, inexpensive, rapid and most appropriate eco-friendly bio-fertilizer for sustainable agriculture. Plant derived smoke was generated by burning of plant material (leaf, straws etc in a specially designed furnace, and seeds were treated with this smoke for different time duration. Four level of plant derived smoke (1 h, 2 h, 3 h and 4 h along with control were tested on four wheat cultivars in CRD repeated pot experiment. The smoke-related treatments modified number of morphological, physiological and biochemical features of wheat. Compared with the control, aerosol smoke treatment of the seeds significantly improved root length (2.6%, shoot length (7.7%, RFW (0.04%, SFW (0.7%, SDW (0.1% and leaf area (63.9%. All the smoke-related treatments significantly promoted RWC (17.3%, water potential (1.5%, osmotic potential (1.4% and MSI (14.6% whereas a pronounced increase in chlorophyll a (24.9%, chlorophyll b (21.7% and total chlorophyll contents (15.5% were recorded in response to aerosol-smoke treatments. Plant derived smoke exposure applied for short time i.e. 1 h & 2 h induced significant results as compared to prolonged PDS exposure (3 h and 4 h. The best results were observed in Pak-13 and Glaxy-13 wheat cultivars. These findings indicated that the plant-derived smoke treatment has a great potential to improve morphological, physiological and biochemical features of wheat crop.

  17. Search for biochemical fossils on earth and non-biological organic molecules on Jupiter, Saturn and Titan

    Science.gov (United States)

    Nagy, Bartholomew

    1982-07-01

    Recognizable remnants of ancient biochemicals may survive under mild/moderate geological environments. Acyclic isoprenoid hydrocarbons, cyclic hydrocarbons with terpenoid carbon skeletons (e.g. hopanes) and vanadyl and nickel porphyrins have been isolated from organic matter, including petroleum, in Phanerozoic sedimentary rocks. Remnants of lignin have also been found. Usually, carbohydrates do not survive long; they degrade and/or react with other organic substances to form macromolecular matter. Proteins, e.g. apparently those in dinosaur bone collagen, break down relatively rapidly. Life arose during the Precambrian and potential biochemical fossils, e.g. n-alkanes, 2,5-dimethylfuran have been isolated from Precambrian kerogens. Traces of hydrocarbons, NH3, PH3 occur on Jupiter and Saturn. Hydrocarbons, N2 and HCN, the latter a key intermediary in the laboratory abiological syntheses of amino acids and nucleic acid bases, are present on Titan where life could not have evolved. Precursor abiological organic molecules of some complexity may have been synthesized on Titan and the Jovian planets.

  18. Rapid impact testing for quantitative assessment of large populations of bridges

    Science.gov (United States)

    Zhou, Yun; Prader, John; DeVitis, John; Deal, Adrienne; Zhang, Jian; Moon, Franklin; Aktan, A. Emin

    2011-04-01

    Although the widely acknowledged shortcomings of visual inspection have fueled significant advances in the areas of non-destructive evaluation and structural health monitoring (SHM) over the last several decades, the actual practice of bridge assessment has remained largely unchanged. The authors believe the lack of adoption, especially of SHM technologies, is related to the 'single structure' scenarios that drive most research. To overcome this, the authors have developed a concept for a rapid single-input, multiple-output (SIMO) impact testing device that will be capable of capturing modal parameters and estimating flexibility/deflection basins of common highway bridges during routine inspections. The device is composed of a trailer-mounted impact source (capable of delivering a 50 kip impact) and retractable sensor arms, and will be controlled by an automated data acquisition, processing and modal parameter estimation software. The research presented in this paper covers (a) the theoretical basis for SISO, SIMO and MIMO impact testing to estimate flexibility, (b) proof of concept numerical studies using a finite element model, and (c) a pilot implementation on an operating highway bridge. Results indicate that the proposed approach can estimate modal flexibility within a few percent of static flexibility; however, the estimated modal flexibility matrix is only reliable for the substructures associated with the various SIMO tests. To overcome this shortcoming, a modal 'stitching' approach for substructure integration to estimate the full Eigen vector matrix is developed, and preliminary results of these methods are also presented.

  19. Biochemical and molecular tools reveal two diverse Xanthomonas groups in bananas

    DEFF Research Database (Denmark)

    Adriko, John; Aritua, V.; Mortensen, Carmen Nieves

    2016-01-01

    Xanthomonas campestris pv. musacearum (Xcm) causing the banana Xanthomonas wilt (BXW) disease has been the main xanthomonad associated with bananas in East and Central Africa based on phenotypic and biochemical characteristics. However, biochemical methods cannot effectively distinguish between...... pathogenic and non-pathogenic xanthomonads. In this study, gram-negative and yellow-pigmented mucoid bacteria were isolated from BXW symptomatic and symptomless bananas collected from different parts of Uganda. Biolog, Xcm-specific (GspDm), Xanthomonas vasicola species-specific (NZ085) and Xanthomonas genus......-specific (X1623) primers in PCR, and sequencing of ITS region were used to identify and characterize the isolates. Biolog tests revealed several isolates as xanthomonads. The GspDm and NZ085 primers accurately identified three isolates from diseased bananas as Xcm and these were pathogenic when re...

  20. Rapid, high-temperature, field test method for evaluation of geothermal calcium carbonate scale inhibitors

    Energy Technology Data Exchange (ETDEWEB)

    Asperger, R.G.

    1986-09-01

    A new test method is described that allows the rapid field testing of calcium carbonate scale inhibitors at 500/sup 0/F (260/sup 0/C). The method evolved from use of a full-flow test loop on a well with a mass flow rate of about 1 x 10/sup 6/ lbm/hr (126 kg/s). It is a simple, effective way to evaluate the effectiveness of inhibitors under field conditions. Five commercial formulations were chosen for field evaluation on the basis of nonflowing, laboratory screening tests at 500/sup 0/F (260/sup 0/C). Four of these formulations from different suppliers controlled calcium carbonate scale deposition as measured by the test method. Two of these could dislodge recently deposited scale that had not age-hardened. Performance-profile diagrams, which were measured for these four effective inhibitors, show the concentration interrelationship between brine calcium and inhibitor concentrations at which the formulations will and will not stop scale formation in the test apparatus. With these diagrams, one formulation was chosen for testing on the full-flow brine line. The composition was tested for 6 weeks and showed a dramatic decrease in the scaling occurring at the flow-control valve. This scaling was about to force a shutdown of a major, long-term flow test being done for reservoir economic evaluations. The inhibitor stopped the scaling, and the test was performed without interruption.

  1. Effects of time-of-day on oxidative stress, cardiovascular parameters, biochemical markers, and hormonal response following level-1 Yo-Yo intermittent recovery test.

    Science.gov (United States)

    Aloui, K; Abedelmalek, S; Chtourou, H; Wong, D P; Boussetta, N; Souissi, N

    2017-03-01

    The aim of this study was to investigate the effect of time-of-day on oxidative stress, cardiovascular parameters, muscle damage parameters, and hormonal responses following the level-1 Yo-Yo intermittent recovery test (YYIRT). A total of 11 healthy subjects performed an intermittent test (YYIRT) at two times-of-day (i.e., 07:00 h and 17:00 h), with a recovery period of ≥36 h in-between, in a randomized order. Blood samples were taken at the rest (baseline) and immediately (post-YYIRT) after the YYIRT for measuring oxidative stress, biochemical markers, and hormonal response. Data were statistically analyzed using one-way and two-way repeated measures ANOVA and Bonferroni test at p creatine kinase (p  0.05) were similar for the morning and evening test. In conclusion, our findings suggest that aerobic performance presents diurnal variation with great result observed in the evening accompanied by an improvement of hormonal, metabolic, and oxidative responses. These data may help to guide athletes and coaches and contribute to public health recommendations on exercise and muscle damage particularly in the competitive periods.

  2. Changes in the biochemical composition of testes during spermatogenesis in Asterias vulgaris, with emphasis on the role of polyamines in regulating proliferation

    International Nuclear Information System (INIS)

    Smith, F.F.

    1985-01-01

    Testes of Asterias vulgaris are potentially useful for investigating mechanisms regulating spermatogenic events because of their structural simplicity and annual spermatogenic cycle. Examination of major biochemical classes during the spermatogenic cycle provides a definition of the changing chemical microenvironment influencing germinal cells and also suggests temporal relationships among successive spermatogenic events. Testes from seastars collected throughout the year were homogenized and lyophilized and aliquots assayed for DNA, RNA, total protein, free amino acids, total lipids, glycogen, and other carbohydrates; spermatogenic stage was determined by examination of paraffin sections. Activity of ornithine decarboxylase (ODC), the rate-limiting enzyme of polyamine synthesis, increases during the proliferative phase of spermatogenesis. Testicular ODC activity correlates well with DNA synthetic rate. To test the possible role of polyamines in regulating initiation of spermatogonial mitoses, intact testes near the beginning of the proliferative phase were incubated in vitro with exogenous polyamines. They subsequently showed a significant increase in incorporation of 3 H-thymidine into DNA. These results suggest a direct role for polyamines in the regulation of spermatogenic proliferation in a. vulgaris. Evidence for a regulatory role of polyamines in the initiation of proliferation, together with existing information on the environmental, hormonal, and cytological interactions, facilitates development of a preliminary model for regulation and entrainment of spermatogenesis

  3. Biochemical basis for the action of radioprotective drugs

    International Nuclear Information System (INIS)

    Romantsev, E.F.; Blokhina, V.D.; Zhulanova, Z.I.; Koshcheenko, N.N.; Filippovich, I.V.

    1977-01-01

    The hypothesis of complex biochemical mechanism of action of radioprotective drugs is described. Shortly after injection of radioprotective aminothiols into animals the inhibition of radiosensitive biochemical processes: DNA and RNA synthesis, protein synthesis and oxidative phosphorylation has been observed. The molecular mechanism of these phenomena consists of radioprotectors ability to form adsorption, thioester, amide, and disulphide bonds with appropriate enzymes. The curve reflecting the formation and breakdown of mixed disulphides between radioprotectors and proteins coincides well with that reflecting the radioprotective effect dependence on time. The radiobiological significance of molecular interactions observed may be interpreted as the diminution in ''spoiled'' molecules formation (inhibition of replication) and elevation in repartion rate. The inhibition of biochemical processes has the reversible nature and last for short time. The drugs acting according to so-called oxygen effect protect also by means of biochemical mechanisms. The molecular mechanism is mediated through their ability to bind to receptors, and biologically important molecules and macromolecules. As a result the inhibition of radiosensitive processes occurs, the ''spoiled'' molecules number is diminished and reparation takes place more easily. The idea on the complex biochemical mechanism of action of radioprotectors correlates with the proposal on complex biochemical mechanism responsible for interphase death occured after irradiation

  4. Usefulness of a rapid faecal calprotectin test to predict relapse in Crohn's disease patients on maintenance treatment with adalimumab.

    Science.gov (United States)

    Ferreiro-Iglesias, Rocio; Barreiro-de Acosta, Manuel; Lorenzo-Gonzalez, Aurelio; Dominguez-Muñoz, Juan Enrique

    2016-01-01

    Predicting relapse in Crohn's disease (CD) patients by measuring non-invasive biomarkers could allow for early changes of treatment. Data are scarce regarding the utility of monitoring calprotectin to predict relapse. The aim of the study was to evaluate the predictive value of a rapid test of faecal calprotectin (FC) to predict for flares in CD patients on maintenance treatment with adalimumab (ADA). A prospective, observational cohort study was designed. Inclusion criteria were CD patients in clinical remission on a standard dose of ADA therapy. Fresh FC was measured using a rapid test. Thirty patients were included (median age 38 years, 56.7% female). After the 4 months follow-up, 70.0% patients remained in clinical remission and 30.0% had a relapse. FC concentration at inclusion was significantly higher in those patients who relapsed during the follow-up (625 μg/g) compared to those who stayed in remission (45 μg/g). The optimal cut-off for FC to predict relapse was 204 μg/g. The area under the receiver-operating characteristic curve was 0.968. Sensitivity, specificity, positive, and negative predictive value of FC to predict relapse were 100%, 85.7%, 74.1%, and 100%, respectively. In CD patients on ADA maintenance therapy, FC levels measured with a rapid test allow relapse over the following months to be predicted with high accuracy. Low FC levels exclude relapse within at least 4 months after testing, whereas high levels are associated with relapse in three out of every four patients.

  5. The impact of providing rapid diagnostic malaria tests on fever management in the private retail sector in Ghana: a cluster randomized trial.

    Science.gov (United States)

    Ansah, Evelyn K; Narh-Bana, Solomon; Affran-Bonful, Harriet; Bart-Plange, Constance; Cundill, Bonnie; Gyapong, Margaret; Whitty, Christopher J M

    2015-03-04

    To examine the impact of providing rapid diagnostic tests for malaria on fever management in private drug retail shops where most poor rural people with fever present, with the aim of reducing current massive overdiagnosis and overtreatment of malaria. Cluster randomized trial of 24 clusters of shops. Dangme West, a poor rural district of Ghana. Shops and their clients, both adults and children. Providing rapid diagnostic tests with realistic training. The primary outcome was the proportion of clients testing negative for malaria by a double-read research blood slide who received an artemisinin combination therapy or other antimalarial. Secondary outcomes were use of antibiotics and antipyretics, and safety. Of 4603 clients, 3424 (74.4%) tested negative by double-read research slides. The proportion of slide-negative clients who received any antimalarial was 590/1854 (32%) in the intervention arm and 1378/1570 (88%) in the control arm (adjusted risk ratio 0.41 (95% CI 0.29 to 0.58), Pretail sector significantly reduced dispensing of antimalarials to patients without malaria, did not reduce prescribing of antimalarials to true malaria cases, and appeared safe. Rapid diagnostic tests should be considered for the informal private drug retail sector.Registration Clinicaltrials.gov NCT01907672. © Ansah et al 2015.

  6. Differentiation of Staphylococcus aureus from freshly slaughtered poultry and strains 'endemic' to processing plants by biochemical and physiological tests.

    Science.gov (United States)

    Mead, G C; Norris, A P; Bratchell, N

    1989-02-01

    A comparison was made of 27 'endemic' strains of Staphylococcus aureus and 35 strains from freshly slaughtered birds, isolated at five commercial slaughterhouses processing chickens or turkeys. Of 112 biochemical and physiological tests used, 74 gave results which differed among the strains. Cluster analysis revealed several distinct groupings which were influenced by strain type, processing plant and bird origin; these included a single group at the 72% level of similarity containing most of the 'endemic' strains. In comparison with strains from freshly slaughtered birds, a higher proportion of 'endemic' strains produced fibrinolysin, alpha-glucosidase and urease and were beta-haemolytic on sheep-blood agar. The 'endemic' type also showed a greater tendency to coagulate human but not bovine plasma, and to produce mucoid growth and clumping. The last two properties, relevant to colonization of processing equipment, were less evident in heart infusion broth than in richer media or process water collected during defeathering of the birds.

  7. Rapid diagnostic tests for diagnosing uncomplicated non-falciparum or Plasmodium vivax malaria in endemic countries

    Science.gov (United States)

    Abba, Katharine; Kirkham, Amanda J; Olliaro, Piero L; Deeks, Jonathan J; Donegan, Sarah; Garner, Paul; Takwoingi, Yemisi

    2014-01-01

    Background In settings where both Plasmodium vivax and Plasmodium falciparum infection cause malaria, rapid diagnostic tests (RDTs) need to distinguish which species is causing the patients' symptoms, as different treatments are required. Older RDTs incorporated two test lines to distinguish malaria due to P. falciparum, from malaria due to any other Plasmodium species (non-falciparum). These RDTs can be classified according to which antibodies they use: Type 2 RDTs use HRP-2 (for P. falciparum) and aldolase (all species); Type 3 RDTs use HRP-2 (for P. falciparum) and pLDH (all species); Type 4 use pLDH (fromP. falciparum) and pLDH (all species). More recently, RDTs have been developed to distinguish P. vivax parasitaemia by utilizing a pLDH antibody specific to P. vivax. Objectives To assess the diagnostic accuracy of RDTs for detecting non-falciparum or P. vivax parasitaemia in people living in malaria-endemic areas who present to ambulatory healthcare facilities with symptoms suggestive of malaria, and to identify which types and brands of commercial test best detect non-falciparum and P. vivax malaria. Search methods We undertook a comprehensive search of the following databases up to 31 December 2013: Cochrane Infectious Diseases Group Specialized Register; MEDLINE; EMBASE; MEDION; Science Citation Index; Web of Knowledge; African Index Medicus; LILACS; and IndMED. Selection criteria Studies comparing RDTs with a reference standard (microscopy or polymerase chain reaction) in blood samples from a random or consecutive series of patients attending ambulatory health facilities with symptoms suggestive of malaria in non-falciparum endemic areas. Data collection and analysis For each study, two review authors independently extracted a standard set of data using a tailored data extraction form. We grouped comparisons by type of RDT (defined by the combinations of antibodies used), and combined in meta-analysis where appropriate. Average sensitivities and

  8. Biochemical reactions of the organism

    International Nuclear Information System (INIS)

    Fedorova, A.V.

    1984-01-01

    Effects of mercury, strontium chloride, GMDA, trichlorfon as well as some radionuclides ( 89 Sr, 137 Cs, 203 Hg) were studied on rats. Changes in biochemical parameters (histamine content, activity of cholinesterase and histaminase) are noted. Most noticeable changes were observed in enzymatic activity. Distortion of enzymatic systems and accumulation of intermediate exchange and decay products of tissues in excess quantities affecting other systems can be the reason for changes in the organism. The observed changes in biochemical parameters should be necessarily taken into account at hygienic regulations of harmful effects of enviroment

  9. An assessment of the usefulness of a rapid immuno-chromatographic test, "Determine™ malaria pf" in evaluation of intervention measures in forest villages of central India

    Directory of Open Access Journals (Sweden)

    Shukla Manmohan

    2001-08-01

    Full Text Available Abstract Background Plasmodium falciparum malaria, is a major health problem in forested tribal belt of central India. Rapid and accurate methods are needed for the diagnosis of P. falciparum. We performed a blinded evaluation of the recently introduced Determine™ malaria pf test (Abbott, Laboratories, Japan compared with microscopy and splenomegaly in children in epidemic prone areas of district Mandla to assess the impact of intervention measures. Methods Children aged 2–10 yrs with and without fever were examined for spleen enlargement by medical specialist by establishing a mobile field clinic. From these children thick blood smears were prepared from finger prick and read by a technician. Simultaneously, rapid tests were performed by a field lab attendant. The figures for specificity, sensitivity and predictive values were calculated using microscopy as gold standard. Results In all 349 children were examined. The sensitivity and specificity for Determine rapid diagnostic test were 91 and 80% respectively. The positive predictive values (PPV, negative predictive values (NPV and accuracy of the test were respectively 79, 91 and 85%. On the contrary, the sensitivity and specificity of spleen in detecting malaria infection were 57 and 74 % respectively with PPV of 73%, NPV 59 % and an accuracy of 65%. Conclusions Determine™ malaria rapid diagnostic test is easier and quicker to perform and has other advantages over microscopy in not requiring prior training of personnel or quality control. Thus, highlighting the usefulness of a rapid antigen test in assessing prevailing malaria situation in remote areas.

  10. Health workers' compliance to rapid diagnostic tests (RDTs) to guide malaria treatment: a systematic review and meta-analysis

    NARCIS (Netherlands)

    Kabaghe, Alinune N.; Visser, Benjamin J.; Spijker, Rene; Phiri, Kamija S.; Grobusch, Martin P.; van Vugt, Michèle

    2016-01-01

    The World Health Organization recommends malaria to be confirmed by either microscopy or a rapid diagnostic test (RDT) before treatment. The correct use of RDTs in resource-limited settings facilitates basing treatment onto a confirmed diagnosis; contributes to speeding up considering a correct

  11. Analytical interference by contrast agents in biochemical assays

    DEFF Research Database (Denmark)

    Otnes, Sigrid; Fogh-Andersen, Niels; Rømsing, Janne

    2017-01-01

    Objective. To provide a clinically relevant overview of the analytical interference by contrast agents (CA) in laboratory blood test measurements. Materials and Methods. The effects of five CAs, gadobutrol, gadoterate meglumine, gadoxetate disodium, iodixanol, and iomeprol, were studied on the 29...... most frequently performed biochemical assays. One-day-old plasma, serum, and whole blood were spiked with doses of each agent such that the gadolinium agents and the iodine agents reached concentrations of 0.5mMand 12mg iodine/mL, respectively. Subsequently, 12 assays were reexamined using 1/2 and 1...

  12. Age-associated and breed-associated variations in haematological and biochemical variables in young labrador retriever and miniature schnauzer dogs.

    Science.gov (United States)

    Brenten, Thomas; Morris, Penelope J; Salt, Carina; Raila, Jens; Kohn, Barbara; Schweigert, Florian J; Zentek, Jürgen

    2016-01-01

    Breed, sex and age effects on haematological and biochemical variables were investigated in 24 labrador retriever and 25 miniature schnauzer dogs during the first year of life. Blood samples were taken regularly between weeks 8 and 52. White blood cell and red blood cell counts, haemoglobin concentration, haematocrit, mean cell volume, mean cell haemoglobin, mean cell haemoglobin concentration, platelet count as well as total protein, albumin, calcium, phosphate, alkaline phosphatase, alanine aminotransferase, aspartate aminotransferase, glutamate dehydrogenase, total cholesterol, triglycerides, creatine and urea were evaluated. For all haematological and biochemical parameters, there were significant effects of age on test results. Statistically significant effects for breed and the breed×age interaction on test results were observed for most of the parameters with the exception of haemoglobin. Variations in test results illustrate growth related alterations in body tissue and metabolism leading to dynamic and marked changes in haematological and biochemical parameters, which have to be considered for the interpretation of clinical data obtained from dogs in the first year of life.

  13. A re-assessment of biochemical marker distributions in T21 affected and unaffected twin pregnancies in the first trimester

    DEFF Research Database (Denmark)

    Madsen, Helen Nordahl; Ball, Susan; Wright, Dave

    2011-01-01

    OBJECTIVE: To estimate the difference between levels of the two biochemical markers pregnancy-associated plasma protein-A (PAPP-A) and maternal serum free β-human chorionic gonadotropin (free β-hCG) in twin pregnancies relative to singleton pregnancies and establish an improved screening procedure...... of the biochemical markers were calculated. Detection rates and false-positive rates were estimated for screening tests incorporating nuchal translucency and maternal age, with and without biochemistry. RESULTS: Medians for the two biochemical markers for monochorionic and dichorionic twins in unaffected pregnancies......-trimester screening for chromosomal abnormalities in twins to a level comparable with that in singleton pregnancies....

  14. The role of biochemical variations and genotype testing in determining the virological response of patients infected with hepatitis C virus

    Directory of Open Access Journals (Sweden)

    Abid Shoukat

    2018-01-01

    Full Text Available Background: In hepatitis C virus (HCV, infection viral and IL28B genotype along with many clinical and biochemical factors can influence response rates to pegylated interferon plus ribavirin (Peg-IFN-a/R therapy and progression to chronic hepatitis C (CHC. Aims: The present study was conducted to determine the effect of biochemical and risk factors on treatment outcome in CHC patients in relation to their viral and host genotype. Settings and Design: The present study was a prospective Pe- IFN efficacy study consisting of Peg-IFN-a/R therapy for 24–48 weeks including 250 HCV infected patients. Materials and Methods: Biochemical parameters were determined by Beckman Coulter AU680 automated analyzer. HCV and Interleukin 28B (IL28B genotyping were carried out by polymerase chain reaction-restriction fragment length polymorphism and viral load was determined by quantitative real-time PCR. Results: Wild outnumbered the variant genotypes in rs 12979860, rs 12980275, and rs 8099917 SNP of IL28B gene. Sustained virological response (SVR SVR and viral genotype were significantly associated with age, hepatic steatosis, low-grade varices, and serum aspartate transaminase levels (at the end of treatment (P < 0.05. In addition, SVR was significantly influenced by body mass index (BMI, insulin resistance, serum low-density lipoprotein , and ferritin levels (P < 0.05. Viral genotype 1 infected patients had higher serum cholesterol and triglyceride levels (P < 0.05. Conclusions: Although the IL28B sequence variation is the major factor that can influence response rates to antiviral therapy, viral and biochemical factors also have a definite role to play in the diagnosis, etiology, and treatment outcome in HCV-infected patients.

  15. Prevalence of biochemical and immunological abnormalities in ...

    African Journals Online (AJOL)

    Tile prevalence of biochemical and immunological abnormalities was studied in a group of 256 patients with rheumatoid arthritis (104 coloureds, 100 whites and 52 blacks). The most common biochemical abnormalities detected were a reduction in the serum creatinine value (43,4%), raised globulins (39,7%), raised serum ...

  16. [Biochemical diagnostics of fatal opium intoxication].

    Science.gov (United States)

    Papyshev, I P; Astashkina, O G; Tuchik, E S; Nikolaev, B S; Cherniaev, A L

    2013-01-01

    Biochemical diagnostics of fatal opium intoxication remains a topical problem in forensic medical science and practice. We investigated materials obtained in the course of forensic medical expertise of the cases of fatal opium intoxication. The study revealed significant differences between myoglobin levels in blood, urine, myocardium, and skeletal muscles. The proposed approach to biochemical diagnostics of fatal opium intoxication enhances the accuracy and the level of evidence of expert conclusions.

  17. A rapid, sensitive and reliable diagnostic test for scrub typhus in China

    Directory of Open Access Journals (Sweden)

    Zhang Lijuan

    2011-01-01

    Full Text Available Purpose: To evaluate the performances for detection of IgM and IgG antibodies to Orientia. tsutsugamushi (Ot using a gold conjugate-based rapid diagnostic test (RDT. Materials and Methods: The RDT employing mixture recombinant 56-kDa proteins of O. tsutsugamushi and the mIFA assay was performed on 33 patients from Fujian and Yunnan province respectively and 94 positive sera (36 from Hainan province and 58 from Jiangsu province from convalescent stages of the patients with scrub typhus respectively and 82 negative sera from healthy farmers from Anhui province and Beijing City respectively in 2009. A comparison of the RDT and mIFA assay was performed by using the c2 test and the P level of ≤0.05 was considered to be significant. Results: Among these 94 positive sera from convalescent stages of the illness and 82 sera from control farmers, the specificity of RDT was 100% for both IgM and IgG tests. In 33 cases with scrub typhus, 5 cases were positively detected earlier by RDT than by mIFA for the IgM test, and 2 cases were positive for the IgG test. The sensitivities of RDT were 93.9% and 90.9% for IgM and IgG, respectively. Considering IgM and IgG together, the sensitivity was 100%. The geometric mean titre (GMT of IFA and the RDT assay in diluted sera from confirmed cases were 1:37 versus 1:113 respectively (P<0.001 for IgM test and 1:99 versus 1:279 respectively (P<0.016 for IgG. Conclusions: The RDT was more sensitive than the traditional IFA for the early diagnosis of scrub typhus and was particularly suitable for use in rural areas.

  18. Prospective evaluation of three rapid diagnostic tests for diagnosis of human leptospirosis.

    Directory of Open Access Journals (Sweden)

    Marga G A Goris

    Full Text Available BACKGROUND: Diagnosis of leptospirosis by the microscopic agglutination test (MAT or by culture is confined to specialized laboratories. Although ELISA techniques are more common, they still require laboratory facilities. Rapid Diagnostic Tests (RDTs can be used for easy point-of-care diagnosis. This study aims to evaluate the diagnostic performance of the RDTs LeptoTek Dri Dot, LeptoTek Lateral Flow, and Leptocheck-WB, prospectively. METHODOLOGY: During 2001 to 2012, one or two of the RDTs at the same time have been applied prior to routine diagnostics (MAT, ELISA and culture on serum specimens from participants sent in for leptospirosis diagnosis. The case definition was based on MAT, ELISA and culture results. Participants not fulfilling the case definition were considered not to have leptospirosis. The diagnostic accuracy was determined based on the 1(st submitted sample and paired samples, either in an overall analysis or stratified according to days post onset of illness. RESULTS: The overall sensitivity and specificity for the LeptoTek Dri Dot was 75% respectively 96%, for the LeptoTek Lateral Flow 78% respectively 95%, and for the Leptocheck-WB 78% respectively 98%. Based on the 1(st submitted sample the sensitivity was low (51% for LeptoTek Dri Dot, 69% for LeptoTek Lateral Flow, and 55% for Leptocheck-WB, but substantially increased when the results of paired samples were combined, although accompanied by a lower specificity (82% respectively 91% for LeptoTek Dri Dot, 86% respectively 84% for LeptoTek Lateral Flow, and 80% respectively 93% for Leptocheck-WB. CONCLUSIONS: All three tests present antibody tests contributing to the diagnosis of leptospirosis, thus supporting clinical suspicion and contributing to awareness. Since the overall sensitivity of the tested RDTs did not exceed 80%, one should be cautious to rely only on an RDT result, and confirmation by reference tests is strongly recommended.

  19. Performance of the Quidel Sofia Rapid Influenza Diagnostic Test During the 2012-2013 and 2013-2014 Influenza Seasons

    Science.gov (United States)

    2016-03-23

    Performance of the Quidel Sofia rapid influenza diagnostic test during the 2012–2013 and 2013–2014 influenza seasons Peter E. Kammerer, Jennifer M... Influenza A+B Fluorescent Immunoassay was used to test nasal swab specimens from patients with influenza -like illness at US–Mexico border-area clinics in...the 2012–2013 and 2013–2014 influenza seasons. Compared with real-time reverse transcription polymerase chain reaction, the overall sensitivities and

  20. A simple kit for rapid field diagnosis of potato virus Y by latex serological test

    Directory of Open Access Journals (Sweden)

    Aarne Kurppa

    1987-07-01

    Full Text Available A simple kit for rapid detection of potato virus Y by latex serological test was developed. The test is carried out on a white cardboard sheet and the results can be read by naked eye in two minutes. A test card of 10 x 6 cm holds latex sensitized antibodies, buffers and other necessary ingredients as dry blue colored formulate on the ringed areas of the card. A test card includes space for six tests and positive and negative controls. The kit also includes disposable plastic sticks for mixing the samples with test reagents and a hand press with disposable plastic tips. For testing, dried reagents are dissolved in drops of sample and mixed. After gentle rotation, samples containing virus appear clearly granulated while samples from healthy plants remain unagglutinated. The testing of undiluted extracts of evenly developed tuber sprouts resulted in over 91 % identity with the results obtained with ELISA that was used as a control method. Testing of diluted leaf extracts reached the same reliability but undiluted leaf extracts from glasshouse grown potatoes were not well suitable as test samples because of their dark green color. No such problems occurred with field grown material and a complete identity with the ELISA readings was true when the samples included secondarily infected potato plants. No reaction to other potato viruses than PVY was obtained by the test kit.

  1. Accuracy of a rapid 10-minute carbon-14 urea breath test for the diagnosis of Helicobacter pylori-associated peptic ulcer disease

    Energy Technology Data Exchange (ETDEWEB)

    Chiahung, Kao [Taichung Veterans General Hospital (Taiwan, Province of China). Dept. of Nuclear Medicine; Shyhjen, Wang [Taichung Veterans General Hospital (Taiwan, Province of China). Dept. of Nuclear Medicine; Chungyuan, Hsu [Taichung Veterans General Hospital (Taiwan, Province of China). Dept. of Nuclear Medicine; Wanyu, Lin [Taichung Veterans General Hospital (Taiwan, Province of China). Dept. of Nuclear Medicine; Chihkua, Huang [Taichung Veterans General Hospital (Taiwan, Province of China). Dept. of Gastroenterology; Granhum, Chen [Taichung Veterans General Hospital (Taiwan, Province of China). Dept. of Gastroenterology

    1993-08-01

    Urease in the human gastric mucosa is a marker for infection with Helicobacter pylori (HP), an organism which is associated with peptic ulcer disease. To detect gastric urease, we examined 184 patients (144 males, 40 females; mean age: 49.8[+-]15.6 years) with suspected peptic ulcer disease. Fasting patients were given orally 5 [mu]Ci of carbon-14 labelled urea. For each patient only one breath sample was collected in hyamine at 10 min. The amount of [sup 14]C collected at 10 min was expressed as follows: (DPM/mmol CO[sub 2] collected)/(DPM administered)x100xbody weight (kg). The presence of HP colonization was determined by examination of multiple endoscopic prepyloric antral biopsy specimens subjected to culture or a rapid urease test. For the purpose of this study, HP-positive patients were defined as those with characteristic bacteria as indicated by a positive result of either the culture or the rapid urease test; HP-negative patients were defined as those with negative findings on both the culture and the rapid urease test. Of the 184 cases, 99 (53.8%) were positive for HP infection, and 85 (46.2%), negative. The sensitivity and specificity of the rapid 10 min [sup 14]C-urea breath test for the diagnosis of HP-associated peptic ulcer disease were evaluated by a receiver operating characteristic (ROC) curve with a variable cut-off value from 1.5 to 4.5. When a cut-off value of 1.5 was selected, the sensitivity was 100% and the specificity, 83.5%; when a cut-off value of 4.5 was selected, the sensitivity was 54.5% and the specificity, 97.6%. (orig.)

  2. Accuracy of a rapid 10-minute carbon-14 urea breath test for the diagnosis of Helicobacter pylori-associated peptic ulcer disease

    International Nuclear Information System (INIS)

    Kao Chiahung; Wang Shyhjen; Hsu Chungyuan; Lin Wanyu; Huang Chihkua; Chen Granhum

    1993-01-01

    Urease in the human gastric mucosa is a marker for infection with Helicobacter pylori (HP), an organism which is associated with peptic ulcer disease. To detect gastric urease, we examined 184 patients (144 males, 40 females; mean age: 49.8±15.6 years) with suspected peptic ulcer disease. Fasting patients were given orally 5 μCi of carbon-14 labelled urea. For each patient only one breath sample was collected in hyamine at 10 min. The amount of 14 C collected at 10 min was expressed as follows: [(DPM/mmol CO 2 collected)/(DPM administered)]x100xbody weight (kg). The presence of HP colonization was determined by examination of multiple endoscopic prepyloric antral biopsy specimens subjected to culture or a rapid urease test. For the purpose of this study, HP-positive patients were defined as those with characteristic bacteria as indicated by a positive result of either the culture or the rapid urease test; HP-negative patients were defined as those with negative findings on both the culture and the rapid urease test. Of the 184 cases, 99 (53.8%) were positive for HP infection, and 85 (46.2%), negative. The sensitivity and specificity of the rapid 10 min 14 C-urea breath test for the diagnosis of HP-associated peptic ulcer disease were evaluated by a receiver operating characteristic (ROC) curve with a variable cut-off value from 1.5 to 4.5. When a cut-off value of 1.5 was selected, the sensitivity was 100% and the specificity, 83.5%; when a cut-off value of 4.5 was selected, the sensitivity was 54.5% and the specificity, 97.6%. (orig.)

  3. A method for rapid testing of the photosynthesis-inhibiting activity of herbicides by leaf disk infiltration

    Directory of Open Access Journals (Sweden)

    Krzysztof Bielecki

    2013-12-01

    Full Text Available A method for rapid detection of photosynthesis inhibitors in low concentration (0.25-1.25 ppm was developed. The experiments were performed on disks cut from young bean leaves. The disks were infiltrated with solutions of the tested compounds and placed at the bottom of a crystallizer containing an acidic sodium carbonate solution and then illuminated. The toxicity of the tested substance was measured as the number of disks corning to the surface. It was found that linuron, monolinuron, metoksuron, atrazine and prometrine inhibited floating of the disks, whereas 2,4,5-T, MCPA and chlorpropham gave no effect. This confirms the specificity of the test which is appropriate for determining the phytotoxicity of typical photosynthesis inhibitors.

  4. Biochemical aspects of the neoplastic cell in relation to positive indicators

    International Nuclear Information System (INIS)

    Strom, R.

    1975-01-01

    In scintigraphic diagnoses with positive indicators, the capacity of these indicators to fix themselves or to selectively concentrate in the neoplastic tissue is utilized. This selectivity could be due to several biochemical peculiarities of the tumor cells in relation to surrounding cells: the presence on the membrane of particular chemical groups which allow these cells to invade adjacent tissue without being subject to contact inhibition; the presence on these same membranes of antigenic determinants which are particular to these cells and which can be revealed with specific antibodies; a high concentration of nucleic acid in tumor cells, with the associated possibility of fixing substances having a particular tropism for nucleic acids or for their chemical constituents; an elevated rate of nucleic acid synthesis, with an associated increase in the incorporation of precursors and also of substances which specifically interfere with this biochemical pathway; in numerous cases, tumor cells produce high quantities of acidic metabolites which must be neutralized by equivalent quantities of anions, the latter entering the cells by active transport phenomena; in tumors which develop particularly rapidly, there is a development of degenerative processes with an accumulation of degradation products; in metastatic tumors, the cells have metabolic and biosynthetic activities which are a function of the original tissue, with the possiblity of a clear metabolic difference in relation to adjacent tissues [fr

  5. Rapid microbiological testing: monitoring the development of bacterial stress.

    Directory of Open Access Journals (Sweden)

    Boris Zavizion

    2010-10-01

    Full Text Available The ability to respond to adverse environments effectively along with the ability to reproduce are sine qua non conditions for all sustainable cellular forms of life. Given the availability of an appropriate sensing modality, the ubiquity and immediacy of the stress response could form the basis for a new approach for rapid biological testing. We have found that measuring the dielectric permittivity of a cellular suspension, an easily measurable electronic property, is an effective way to monitor the response of bacterial cells to adverse conditions continuously. The dielectric permittivity of susceptible and resistant strains of Escherichia coli and Staphylococcus aureus, treated with gentamicin and vancomycin, were measured directly using differential impedance sensing methods and expressed as the Normalized Impedance Response (NIR. These same strains were also heat-shocked and chemically stressed with Triton X-100 or H(2O(2. The NIR profiles obtained for antibiotic-treated susceptible organisms showed a strong and continuous decrease in value. In addition, the intensity of the NIR value decrease for susceptible cells varied in proportion to the amount of antibiotic added. Qualitatively similar profiles were found for the chemically treated and heat-shocked bacteria. In contrast, antibiotic-resistant cells showed no change in the NIR values in the presence of the drug to which it is resistant. The data presented here show that changes in the dielectric permittivity of a cell suspension are directly correlated with the development of a stress response as well as bacterial recovery from stressful conditions. The availability of a practical sensing modality capable of monitoring changes in the dielectric properties of stressed cells could have wide applications in areas ranging from the detection of bacterial infections in clinical specimens to antibiotic susceptibility testing and drug discovery.

  6. Toxicological Study of Ocimum sanctum Linn Leaves: Hematological, Biochemical, and Histopathological Studies

    Directory of Open Access Journals (Sweden)

    M. K. Gautam

    2014-01-01

    Full Text Available The present study was aimed to study the acute and subacute toxicity studies with orally administered 50% ethanolic leaves extract of Ocimum sanctum Linn (OSE. In acute toxicity tests, four groups of mice (n=6/group/sex were orally treated with doses of 200, 600, and 2000 mg/kg, and general behavior, adverse effects, and mortality were recorded for up to 14 days. In subacute toxicity study, rats received OSE by gavage at the doses of 200, 400, and 800 mg/kg/day (n=6/group/sex for 28 days, and biochemical, hematological, and histopathological changes in tissues (liver, kidney, spleen, heart, and testis/ovary were determined. OSE did not produce any hazardous symptoms or death and CNS and ANS toxicities in the acute toxicity test. Subacute treatment with OSE did not show any change in body weight, food and water consumption, and hematological and biochemical profiles. In addition, no change was observed both in macroscopic and microscopic aspects of vital organs in rats. Our result showed that Ocimum sanctum extract could be safe for human use.

  7. Evaluating quality management systems for HIV rapid testing services in primary healthcare clinics in rural KwaZulu-Natal, South Africa

    OpenAIRE

    Jaya, Ziningi; Drain, Paul K.; Mashamba-Thompson, Tivani P.

    2017-01-01

    Introduction Rapid HIV tests have improved access to HIV diagnosis and treatment by providing quick and convenient testing in rural clinics and resource-limited settings. In this study, we evaluated the quality management system for voluntary and provider-initiated point-of-care HIV testing in primary healthcare (PHC) clinics in rural KwaZulu-Natal (KZN), South Africa. Material and methods We conducted a quality assessment audit in eleven PHC clinics that offer voluntary HIV testing and couns...

  8. Modelling biochemical reaction systems by stochastic differential equations with reflection.

    Science.gov (United States)

    Niu, Yuanling; Burrage, Kevin; Chen, Luonan

    2016-05-07

    In this paper, we gave a new framework for modelling and simulating biochemical reaction systems by stochastic differential equations with reflection not in a heuristic way but in a mathematical way. The model is computationally efficient compared with the discrete-state Markov chain approach, and it ensures that both analytic and numerical solutions remain in a biologically plausible region. Specifically, our model mathematically ensures that species numbers lie in the domain D, which is a physical constraint for biochemical reactions, in contrast to the previous models. The domain D is actually obtained according to the structure of the corresponding chemical Langevin equations, i.e., the boundary is inherent in the biochemical reaction system. A variant of projection method was employed to solve the reflected stochastic differential equation model, and it includes three simple steps, i.e., Euler-Maruyama method was applied to the equations first, and then check whether or not the point lies within the domain D, and if not perform an orthogonal projection. It is found that the projection onto the closure D¯ is the solution to a convex quadratic programming problem. Thus, existing methods for the convex quadratic programming problem can be employed for the orthogonal projection map. Numerical tests on several important problems in biological systems confirmed the efficiency and accuracy of this approach. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Biochemical characterization of MLH3 missense mutations does not reveal an apparent role of MLH3 in Lynch syndrome

    DEFF Research Database (Denmark)

    Ou, Jianghua; Rasmussen, Merete; Westers, Helga

    2009-01-01

    for eight of these MLH3 UVs identified in suspected Lynch syndrome patients, we performed several biochemical tests. We determined the protein expression and stability, protein localization and interaction of the mutant MLH3 proteins with wildtype MLH1. All eight MLH3 UVs gave protein expression levels...... comparable with wildtype MLH3. Furthermore, the UV-containing proteins, in contrast to previous studies, were all localized normally in the nucleus and they interacted normally with wildtype MLH1. Our different biochemical assays yielded no evidence that the eight MLH3 UVs tested are the cause of hereditary...

  10. Radiometric cytolysis inhibition assay, a new rapid test for neutralizing antibodies to intact and trypsin-cleaved poliovirus

    International Nuclear Information System (INIS)

    Hovi, T.; Roivainen, M.

    1989-01-01

    We have developed a new rapid test, the radiometric cytolysis inhibition assay (RACINA), for the determination of neutralizing poliovirus antibodies. HeLa cells prelabeled with 51 Cr, [ 3 H]leucine, or, preferentially, with [ 3 H]uridine are used as sensitive quantitative indicators of residual infectious virus. Both suspensions and monolayer cultures of the indicator cells can be used. Neutralization of a fraction of a high-titer virus preparation can be scored after the first replication cycle at 8 to 10 h. By lowering the incubation temperature to 30 degree C, the completion of the cytolysis due to the first replication cycle of poliovirus was delayed beyond 21 h. This makes it possible to use the RACINA, unlike the standard microneutralization assay, for measuring antibodies to trypsin-cleaved polioviruses. The RACINA was found to be as sensitive as and more reproducible than the standard microneutralization assay in the measurement of neutralizing poliovirus antibodies. The RACINA is a rapid and reliable test for neutralizing antibodies and in principle it may be applicable for quantitation of neutralizing antibodies to other cytolytic agents as well

  11. PCR-based verification of positive rapid diagnostic tests for intestinal protozoa infections with variable test band intensity.

    Science.gov (United States)

    Becker, Sören L; Müller, Ivan; Mertens, Pascal; Herrmann, Mathias; Zondie, Leyli; Beyleveld, Lindsey; Gerber, Markus; du Randt, Rosa; Pühse, Uwe; Walter, Cheryl; Utzinger, Jürg

    2017-10-01

    Stool-based rapid diagnostic tests (RDTs) for pathogenic intestinal protozoa (e.g. Cryptosporidium spp. and Giardia intestinalis) allow for prompt diagnosis and treatment in resource-constrained settings. Such RDTs can improve individual patient management and facilitate population-based screening programmes in areas without microbiological laboratories for confirmatory testing. However, RDTs are difficult to interpret in case of 'trace' results with faint test band intensities and little is known about whether such ambiguous results might indicate 'true' infections. In a longitudinal study conducted in poor neighbourhoods of Port Elizabeth, South Africa, a total of 1428 stool samples from two cohorts of schoolchildren were examined on the spot for Cryptosporidium spp. and G. intestinalis using an RDT (Crypto/Giardia DuoStrip; Coris BioConcept). Overall, 121 samples were positive for G. intestinalis and the RDT suggested presence of cryptosporidiosis in 22 samples. After a storage period of 9-10 months in cohort 1 and 2-3 months in cohort 2, samples were subjected to multiplex PCR (BD Max™ Enteric Parasite Panel, Becton Dickinson). Ninety-three percent (112/121) of RDT-positive samples for G. intestinalis were confirmed by PCR, with a correlation between RDT test band intensity and quantitative pathogen load present in the sample. For Cryptosporidium spp., all positive RDTs had faintly visible lines and these were negative on PCR. The performance of the BD Max™ PCR was nearly identical in both cohorts, despite the prolonged storage at disrupted cold chain conditions in cohort 1. The Crypto/Giardia DuoStrip warrants further validation in communities with a high incidence of diarrhoea. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Evaluation of Rapid Stain IDentification (RSID™ Reader System for Analysis and Documentation of RSID™ Tests

    Directory of Open Access Journals (Sweden)

    Pravatchai W. Boonlayangoor

    2013-08-01

    Full Text Available The ability to detect the presence of body fluids is a crucial first step in documenting and processing forensic evidence. The Rapid Stain IDentification (RSID™ tests for blood, saliva, semen and urine are lateral flow immunochromatographic strip tests specifically designed for forensic use. Like most lateral flow strips, the membrane components of the test are enclosed in a molded plastic cassette with a sample well and an observation window. No specialized equipment is required to use these tests or to score the results seen in the observation window; however, the utility of these tests can be enhanced if an electronic record of the test results can be obtained, preferably by a small hand-held device that could be used in the field under low light conditions. Such a device should also be able to “read” the lateral flow strips and accurately record the results of the test as either positive, i.e., the body fluid was detected, or negative, i.e., the body fluid was not detected. Here we describe the RSID™ Reader System—a ruggedized strip test reader unit that allows analysis and documentation of RSID™ lateral flow strip tests using pre-configured settings, and show that the RSID™ Reader can accurately and reproducibly report and record correct results from RSID™ blood, saliva, semen, and urine tests.

  13. Near infrared spectroscopy for determination of various physical, chemical and biochemical properties in Mediterranean soils.

    Science.gov (United States)

    Zornoza, R; Guerrero, C; Mataix-Solera, J; Scow, K M; Arcenegui, V; Mataix-Beneyto, J

    2008-07-01

    The potential of near infrared (NIR) reflectance spectroscopy to predict various physical, chemical and biochemical properties in Mediterranean soils from SE Spain was evaluated. Soil samples (n=393) were obtained by sampling thirteen locations during three years (2003-2005 period). These samples had a wide range of soil characteristics due to variations in land use, vegetation cover and specific climatic conditions. Biochemical properties also included microbial biomarkers based on phospholipid fatty acids (PLFA). Partial least squares (PLS) regression with cross validation was used to establish relationships between the NIR spectra and the reference data from physical, chemical and biochemical analyses. Based on the values of coefficient of determination (r(2)) and the ratio of standard deviation of validation set to root mean square error of cross validation (RPD), predicted results were evaluated as excellent (r(2)>0.90 and RPD>3) for soil organic carbon, Kjeldahl nitrogen, soil moisture, cation exchange capacity, microbial biomass carbon, basal soil respiration, acid phosphatase activity, β-glucosidase activity and PLFA biomarkers for total bacteria, Gram positive bacteria, actinomycetes, vesicular-arbuscular mycorrhizal fungi and total PLFA biomass. Good predictions (0.81fungi were not accurate enough to satisfactorily estimate these variables, only permitting approximate predictions (0.66rapid, inexpensive and non-destructive technique to predict some physical, chemical and biochemical soil properties for Mediterranean soils, including variables related to the composition of the soil microbial community composition.

  14. Rapid Tooling via Stereolithography

    OpenAIRE

    Montgomery, Eva

    2006-01-01

    Approximately three years ago, composite stereolithography (SL) resins were introduced to the marketplace, offering performance features beyond what traditional SL resins could offer. In particular, the high heat deflection temperatures and high stiffness of these highly filled resins have opened the door to several new rapid prototyping (RP) applications, including wind tunnel test modelling and, more recently, rapid tooling.

  15. Comparison of seasonal effects on some hematological and biochemical parameters between ewes with subclinical mastitis and healthy ewes

    OpenAIRE

    R.N. Sani; M. Moezifar

    2016-01-01

    This study was conducted to compare the effects of season on some hematological and biochemical parameters in ewes with subclinical mastitis and healthy ewes. A total of 1192 milk and blood samples were collected from ewes between February and April (791 samples in spring), August and October (401 samples in summer). California Mastitis Test (CMT), milk culture, hematologic and serum biochemical parameters were obtained from the medical records. Samples which were positive by bacterial cultur...

  16. Changes in biochemical and microbiological parameters during the period of rapid composting of dairy manure with rice chaff.

    Science.gov (United States)

    Liu, Dongyang; Zhang, Ruifu; Wu, Hongsheng; Xu, Dabing; Tang, Zhu; Yu, Guanghui; Xu, Zhihui; Shen, Qirong

    2011-10-01

    Various parameters were measured during the period of composting of dairy manure and rice chaff in different ratios (dairy manure/rice chaff=V/V, pile 1: 75/25; pile 2: 80/20; pile 3: 85/15) to evaluate their suitability as indicators for the composting process. The temperature in pile 1 increased rapidly and remained above 60 °C for 30 days, while the temperature in pile 3 increased slowly relative to the other two piles. Furthermore, the degradation of organic substrates, as indicated by the reduction of C/N ratio, was rapid in pile 1 (below 20% 28 days after beginning of the composting). The major fluctuations of various water-soluble fractions in all piles were observed during the first 3 weeks, and the results in general showed that the highest microbial populations and enzymatic activities also appeared in this phase. Various parameters indicated that the rapid composting method was a feasible one for treating agricultural wastes. Copyright © 2011 Elsevier Ltd. All rights reserved.

  17. Preparation and Testing of Impedance-based Fluidic Biochips with RTgill-W1 Cells for Rapid Evaluation of Drinking Water Samples for Toxicity.

    Science.gov (United States)

    Brennan, Linda M; Widder, Mark W; McAleer, Michael K; Mayo, Michael W; Greis, Alex P; van der Schalie, William H

    2016-03-07

    This manuscript describes how to prepare fluidic biochips with Rainbow trout gill epithelial (RTgill-W1) cells for use in a field portable water toxicity sensor. A monolayer of RTgill-W1 cells forms on the sensing electrodes enclosed within the biochips. The biochips are then used for testing in a field portable electric cell-substrate impedance sensing (ECIS) device designed for rapid toxicity testing of drinking water. The manuscript further describes how to run a toxicity test using the prepared biochips. A control water sample and the test water sample are mixed with pre-measured powdered media and injected into separate channels of the biochip. Impedance readings from the sensing electrodes in each of the biochip channels are measured and compared by an automated statistical software program. The screen on the ECIS instrument will indicate either "Contamination Detected" or "No Contamination Detected" within an hour of sample injection. Advantages are ease of use and rapid response to a broad spectrum of inorganic and organic chemicals at concentrations that are relevant to human health concerns, as well as the long-term stability of stored biochips in a ready state for testing. Limitations are the requirement for cold storage of the biochips and limited sensitivity to cholinesterase-inhibiting pesticides. Applications for this toxicity detector are for rapid field-portable testing of drinking water supplies by Army Preventative Medicine personnel or for use at municipal water treatment facilities.

  18. Biochemical changes in diabetic retinopathy triggered by hyperglycaemia: A review

    Directory of Open Access Journals (Sweden)

    Solani D. Mathebula

    2018-04-01

    Full Text Available Background: Diabetes mellitus (DM is now a global health problem which will lead to increasing incidence of macrovascular and microvascular complications that contribute to morbidity, mortality and premature deaths. Diabetic retinopathy (DR is a serious complication of DM, and its prevalence is increasing worldwide. Diabetes mellitus is one of the fastest growing causes of visual impairment and blindness in the working-age population. Aim: The aim of this paper was to introduce the multiple interconnecting biochemical pathways that have been proposed and tested as key contributors in how the diabetic eye loses vision. Method: An extensive literature search was performed using the Medline database from 1970 to present. The search subjects included diabetes and eye, diabetic retinopathy and diabetic complications in the eye. The search was limited to the literature pertaining to humans and to English language. Preference was given to recent published papers. Results: Results were limited to human participants with publications in English. References of all included papers were also scrutinized to identify additional studies. Studies were selected for inclusion in the review if they met the following criteria: subjects with diabetes, pathophysiology of diabetic retinopathy. Conclusion: Although the biochemical pathways involved in DR have been researched, to date the exact mechanism involved in the onset and progression of the disease is uncertain, which makes therapeutic interventions challenging. The aim of this review is to discuss the possible biochemical pathways and clinical and anatomical changes that occur during the onset and progression of DR that link hyperglycaemia with retinal tissue damage. An understanding of the biochemical and molecular changes may lead to health care practitioners advising patients with DR on events that lead to possible complications of the diseases.

  19. Romer Labs RapidChek®Listeria monocytogenes Test System for the Detection of L. monocytogenes on Selected Foods and Environmental Surfaces.

    Science.gov (United States)

    Juck, Gregory; Gonzalez, Verapaz; Allen, Ann-Christine Olsson; Sutzko, Meredith; Seward, Kody; Muldoon, Mark T

    2018-04-27

    The Romer Labs RapidChek ® Listeria monocytogenes test system (Performance Tested Method ℠ 011805) was validated against the U.S. Department of Agriculture-Food Safety and Inspection Service Microbiology Laboratory Guidebook (USDA-FSIS/MLG), U.S. Food and Drug Association Bacteriological Analytical Manual (FDA/BAM), and AOAC Official Methods of Analysis ℠ (AOAC/OMA) cultural reference methods for the detection of L. monocytogenes on selected foods including hot dogs, frozen cooked breaded chicken, frozen cooked shrimp, cured ham, and ice cream, and environmental surfaces including stainless steel and plastic in an unpaired study design. The RapidChek method uses a proprietary enrichment media system, a 44-48 h enrichment at 30 ± 1°C, and detects L. monocytogenes on an immunochromatographic lateral flow device within 10 min. Different L. monocytogenes strains were used to spike each of the matrixes. Samples were confirmed based on the reference method confirmations and an alternate confirmation method. A total of 140 low-level spiked samples were tested by the RapidChek method after enrichment for 44-48 h in parallel with the cultural reference method. There were 88 RapidChek presumptive positives. One of the presumptive positives was not confirmed culturally. Additionally, one of the culturally confirmed samples did not exhibit a presumptive positive. No difference between the alternate confirmation method and reference confirmation method was observed. The respective cultural reference methods (USDA-FSIS/MLG, FDA/BAM, and AOAC/OMA) produced a total of 63 confirmed positive results. Nonspiked samples from all foods were reported as negative for L. monocytogenes by all methods. Probability of detection analysis demonstrated no significant differences in the number of positive samples detected by the RapidChek method and the respective cultural reference method.

  20. Effects of intramuscular administration of tiletamine-zolazepam with and without sedative pretreatment on plasma and serum biochemical values and glucose tolerance test results in Japanese black bears (Ursus thibetanus japonicus).

    Science.gov (United States)

    Kamine, Akari; Shimozuru, Michito; Shibata, Haruki; Tsubota, Toshio

    2012-08-01

    To establish a safe anesthetic protocol with little effect on blood biochemical values and IV glucose tolerance test (IVGTT) results in Japanese black bears (Ursus thibetanus japonicus). 16 captive female Japanese black bears (5 to 17 years of age). Bears were randomly assigned to 4 treatment groups (4 bears/group) in which various treatment combinations were administered via blow dart: tiletamine HCl and zolazepam HCl (9 mg/kg) alone (TZ), TZ (6 mg/kg) and acepromazine maleate (0.1 mg/kg), TZ (6 mg/kg) and butorphanol tartrate (0.3 mg/kg), or TZ (3 mg/kg) and medetomidine HCl (40 μg/kg). Glucose injection for the IVGTT was started 130 minutes after TZ administration. Blood samples were obtained before, at, and intermittently after glucose injection for measurement of biochemical variables as well as plasma glucose and serum insulin concentrations during the IVGTT. Rectal temperature, pulse rate, and respiratory rate were assessed every 15 minutes during the experiment. Induction and maintenance of anesthesia were safely achieved with little adverse effect on cardiopulmonary function when each of the 4 anesthetic regimens was used, although mild hypothermia was induced. No difference was evident between treatment groups in blood biochemical values. Blood glucose and insulin concentration profiles during the IVGTT were similar among the bears given TZ, with or without acepromazine or butorphanol, but hyperglycemia and hypoinsulinemia developed in bears given TZ with medetomidine. All 4 anesthetic regimens yielded chemical restraint without affecting clinical and biochemical values in bears, but medetomidine appeared to affect IVGTT results. For this reason, medetomidine should not be used when anesthetizing bears for IVGTTs.

  1. Near-infrared Raman spectroscopy for assessing biochemical changes of cervical tissue associated with precarcinogenic transformation.

    Science.gov (United States)

    Duraipandian, Shiyamala; Mo, Jianhua; Zheng, Wei; Huang, Zhiwei

    2014-11-07

    Raman spectroscopy measures the inelastically scattered light from tissue that is capable of identifying native tissue biochemical constituents and their changes associated with disease transformation. This study aims to characterize the Raman spectroscopic properties of cervical tissue associated with the multi-stage progression of cervical precarcinogenic sequence. A rapid-acquisition fiber-optic near-infrared (NIR) Raman diagnostic system was employed for tissue Raman spectral measurements at 785 nm excitation. A total of 68 Raman spectra (23 benign, 29 low-grade squamous intraepithelial lesions (LSIL) and 16 high grade squamous intraepithelial lesions (HSIL)) were measured from 25 cervical tissue biopsy specimens, as confirmed by colposcopy-histopathology. The semi-quantitative biochemical modeling based on the major biochemicals (i.e., DNA, proteins (histone, collagen), lipid (triolein) and carbohydrates (glycogen)) in cervical tissue uncovers the stepwise accumulation of biomolecular changes associated with progressive cervical precarcinogenesis. Multi-class partial least squares-discriminant analysis (PLS-DA) together with leave-one tissue site-out, cross-validation yielded the diagnostic sensitivities of 95.7%, 82.8% and 81.3%; specificities of 100.0%, 92.3% and 88.5%,for discrimination among benign, LSIL and HSIL cervical tissues, respectively. This work suggests that the Raman spectral biomarkers have identified the potential to be used for monitoring the multi-stage cervical precarcinogenesis, forming the foundation of applying NIR Raman spectroscopy for the early diagnosis of cervical precancer in vivo at the molecular level.

  2. Biochemical and toxicological studies of aqueous extract of ...

    African Journals Online (AJOL)

    Biochemical and toxicological studies of aqueous extract of Syzigium ... tract diseases and also used as food spices), on some biochemical indices, such as ... liver functions and blood parameters were studied in adult albino rats of both sexes.

  3. Appropriate targeting of artemisinin-based combination therapy by community health workers using malaria rapid diagnostic tests

    DEFF Research Database (Denmark)

    Ndyomugyenyi, Richard; Magnussen, Pascal; Lal, Sham

    2016-01-01

    OBJECTIVE: To compare the impact of malaria rapid diagnostic tests (mRDTs), used by community health workers (CHWs), on the proportion of children ...-randomized trials were conducted in two contrasting areas of moderate-to-high and low malaria transmission in rural Uganda. Each trial examined the effectiveness of mRDTs in the management of malaria and targeting of ACTs by CHWs comparing two diagnostic approaches: (i) presumptive clinical diagnosis of malaria...

  4. Criteria for the Evaluation and Selection of Radiation-Induced Metabolic Changes as Biochemical Indicators of Radiation Damage

    Energy Technology Data Exchange (ETDEWEB)

    Altman, K. I. [Departments of Experimental Radiology, Radiation Biology, Biophysics and Biochemistry, University of Rochester, School of Medicine and Dentistry, Rochester, NY (United States)

    1971-03-15

    of the indicator should be high in terms of units of response per R exposed to; (3) the detectability of the biochemical response in relation to the time of exposure should, under ideal conditions, be maximal at a single time point during the post-irradiation period and this time point should not vary with the radiation dose; (4) the biochemical procedure for detecting the radiation response should be rapid, simple, and capable of execution in clinical laboratories not necessarily equipped with sophisticated apparatus; (5) the sample to be examined should be readily biopsied without endangering the recovery of the patient (the preferred method is the one which can be repeated several times, i.e. with which samples from the same patient can be obtained repeatedly with impunity); (6) the indicator selected should not suffer from interference by metabolic changes which are related to disease processes not related to the sequelae of exposure to ionizing radiations, e.g. malignancies, intercurrent infections, etc. Since many of the conceivable biochemical indicators depend upon contributions by various organs and thus possess little organ specificity and since other possible indicator systems represent indirect effects mediated by adrenal, pituitary, and other hormones, it seems realistic to assume that no single biochemical indicator will be satisfory in any one situation, but that, instead, multiple biochemical indicators will need to be resorted to in order to explore all possible aspects of radiation damage. Thus, indicators will be needed which are applicable at various dose levels and times after exposure. Furthermore, the ideal indicator system should be applicable after total- as well as partial-body irradiation, a special case of which would be a completely organ-specific indicator. (author)

  5. Development of a stable positive control to be used for quality assurance of rapid diagnostic tests for malaria

    NARCIS (Netherlands)

    Versteeg, Inge; Mens, Petra F.

    2009-01-01

    The objective of this study is to develop and evaluate a simple, cheap, and stable positive control for the quality control and quality assurance (QA) of rapid diagnostic tests (RDT) for the diagnosis of malaria. Plasmodium falciparum in vitro culture of known parasite concentrations was dried on a

  6. Accelerated maximum likelihood parameter estimation for stochastic biochemical systems

    Directory of Open Access Journals (Sweden)

    Daigle Bernie J

    2012-05-01

    Full Text Available Abstract Background A prerequisite for the mechanistic simulation of a biochemical system is detailed knowledge of its kinetic parameters. Despite recent experimental advances, the estimation of unknown parameter values from observed data is still a bottleneck for obtaining accurate simulation results. Many methods exist for parameter estimation in deterministic biochemical systems; methods for discrete stochastic systems are less well developed. Given the probabilistic nature of stochastic biochemical models, a natural approach is to choose parameter values that maximize the probability of the observed data with respect to the unknown parameters, a.k.a. the maximum likelihood parameter estimates (MLEs. MLE computation for all but the simplest models requires the simulation of many system trajectories that are consistent with experimental data. For models with unknown parameters, this presents a computational challenge, as the generation of consistent trajectories can be an extremely rare occurrence. Results We have developed Monte Carlo Expectation-Maximization with Modified Cross-Entropy Method (MCEM2: an accelerated method for calculating MLEs that combines advances in rare event simulation with a computationally efficient version of the Monte Carlo expectation-maximization (MCEM algorithm. Our method requires no prior knowledge regarding parameter values, and it automatically provides a multivariate parameter uncertainty estimate. We applied the method to five stochastic systems of increasing complexity, progressing from an analytically tractable pure-birth model to a computationally demanding model of yeast-polarization. Our results demonstrate that MCEM2 substantially accelerates MLE computation on all tested models when compared to a stand-alone version of MCEM. Additionally, we show how our method identifies parameter values for certain classes of models more accurately than two recently proposed computationally efficient methods

  7. Evaluation of a rapid immunochromatographic ODK-0901 test for detection of pneumococcal antigen in middle ear fluids and nasopharyngeal secretions.

    Directory of Open Access Journals (Sweden)

    Muneki Hotomi

    Full Text Available Since the incidence of penicillin-resistant Streptococcus pneumoniae has been increasing at an astonishing rate throughout the world, the need for accurate and rapid identification of pneumococci has become increasingly important to determine the appropriate antimicrobial treatment. We have evaluated an immunochromatographic test (ODK-0901 that detects pneumococcal antigens using 264 middle ear fluids (MEFs and 268 nasopharyngeal secretions (NPSs. A sample was defined to contain S. pneumoniae when optochin and bile sensitive alpha hemolytic streptococcal colonies were isolated by culture. The sensitivity and specificity of the ODK-0901 test were 81.4% and 80.5%, respectively, for MEFs from patients with acute otitis media (AOM. In addition, the sensitivity and specificity were 75.2% and 88.8%, respectively, for NPSs from patients with acute rhinosinusitis. The ODK-0901 test may provide a rapid and highly sensitive evaluation of the presence of S. pneumoniae and thus may be a promising method of identifying pneumococci in MEFs and NPSs.

  8. eQuilibrator--the biochemical thermodynamics calculator.

    Science.gov (United States)

    Flamholz, Avi; Noor, Elad; Bar-Even, Arren; Milo, Ron

    2012-01-01

    The laws of thermodynamics constrain the action of biochemical systems. However, thermodynamic data on biochemical compounds can be difficult to find and is cumbersome to perform calculations with manually. Even simple thermodynamic questions like 'how much Gibbs energy is released by ATP hydrolysis at pH 5?' are complicated excessively by the search for accurate data. To address this problem, eQuilibrator couples a comprehensive and accurate database of thermodynamic properties of biochemical compounds and reactions with a simple and powerful online search and calculation interface. The web interface to eQuilibrator (http://equilibrator.weizmann.ac.il) enables easy calculation of Gibbs energies of compounds and reactions given arbitrary pH, ionic strength and metabolite concentrations. The eQuilibrator code is open-source and all thermodynamic source data are freely downloadable in standard formats. Here we describe the database characteristics and implementation and demonstrate its use.

  9. eQuilibrator—the biochemical thermodynamics calculator

    Science.gov (United States)

    Flamholz, Avi; Noor, Elad; Bar-Even, Arren; Milo, Ron

    2012-01-01

    The laws of thermodynamics constrain the action of biochemical systems. However, thermodynamic data on biochemical compounds can be difficult to find and is cumbersome to perform calculations with manually. Even simple thermodynamic questions like ‘how much Gibbs energy is released by ATP hydrolysis at pH 5?’ are complicated excessively by the search for accurate data. To address this problem, eQuilibrator couples a comprehensive and accurate database of thermodynamic properties of biochemical compounds and reactions with a simple and powerful online search and calculation interface. The web interface to eQuilibrator (http://equilibrator.weizmann.ac.il) enables easy calculation of Gibbs energies of compounds and reactions given arbitrary pH, ionic strength and metabolite concentrations. The eQuilibrator code is open-source and all thermodynamic source data are freely downloadable in standard formats. Here we describe the database characteristics and implementation and demonstrate its use. PMID:22064852

  10. Rapid detection, characterization, and enumeration of foodborne pathogens

    DEFF Research Database (Denmark)

    Hoorfar, Jeffrey

    2011-01-01

    . The present review discusses the reasons for the increasing interest in rapid methods; current developments in the field, the research needs, and the future trends. The advent of biotechnology has introduced new technologies that led to the emergence of rapid diagnostic methods and altered food testing...... of rapid methods is for fast screening of large number of samples, where most of them are expected to be test-negative, leading to faster product release for sale. This has been the main strength of rapid methods such as real-time Polymerase Chain Reaction (PCR). Enrichment PCR, where a primary culture...... of pathogen in a contaminated product. Another key issue is automation, where the key drivers are miniaturization and multiple testing, which mean that not only one instrument is flexible enough to test for many pathogens but also many pathogens can be detected with one test. The review is mainly based...

  11. Rapid radioimmunological test for HCG in normal and disturbed early pregnancy

    International Nuclear Information System (INIS)

    Dericks-Tan, J.S.E.; Taubert, H.D.

    1979-01-01

    The clinical evaluation of a rapid radioimmunological test for HCG in serum showed that this method is as suitable as conventional radioimmunoassay or receptor methods in the diagnosis of normal and disturbed early pregnancy. Using a direct immunosorbent method total time requirements for the estimation could be reduced to half a working day. Sera of 314 women with normal pregnancies showed an exponential increase of HCG concentrations in serum during the first 8 weeks and thereafter steady levels for several weeks. As the anti-HCG serum used has only a slight cross reactivity with LH, false-positive results need hardly be expected in states if high LH levels in serum (menopause, polycystic ovaries, preovulatory LH peak). HCG concentrations in serum were clearly diminished in all pregnancies ending in abortion and in nearly all extrauterine pregnancies. Repeated estimations in early pregnancy enable a diagnosis of ectopic or disturbed intrauterine pregnancy to be made before symptoms of rupture, haemorrhage and similar complications occur. (orig.) [de

  12. Clinical laboratory evaluation of the Auto-Microbic system for rapid identification of Enterobacteriaceae.

    OpenAIRE

    Hasyn, J J; Cundy, K R; Dietz, C C; Wong, W

    1981-01-01

    The capability of the Auto-Microbic system (Vitek Systems, Inc., Hazelwood, Mo.) has been expanded to identify members of the family Enterobacteriaceae with the use of a sealed, disposable accessory card (the Enterobacteriaceae Biochemical Card) containing 26 biochemical tests. To judge the accuracy of the AutoMicrobic system's identification in a hospital laboratory, 933 Enterobacteriaceae isolates were studied. The AutoMicrobic system provided the correct identification for 905 of the isola...

  13. A rapid phenol toxicity test based on photosynthesis and movement of the freshwater flagellate, Euglena agilis Carter

    International Nuclear Information System (INIS)

    Kottuparambil, Sreejith; Kim, Youn-Jung; Choi, Hoon; Kim, Mi-Sung; Park, Areum; Park, Jihae; Shin, Woongghi; Han, Taejun

    2014-01-01

    Highlights: • Rapid phenol toxicity tests (1 h) were developed based on Chl a fluorescence and the movement parameters of Euglena agilis. • Phenol significantly reduced F v /F m of PS II and rETRmax with EC50 values of 8.94 and 4.67 mM, respectively. • Among the movement parameters tested, velocity was the most sensitive biomarker with an EC50 of 3.17 mM. • The EC50 values for F v /F m , motility, and velocity appear to overlap the environmental permissible levels of phenol. - Abstract: Phenol, a monosubstituted aromatic hydrocarbon with various commercial uses, is a major organic constituent in industrial wastewaters. The ecotoxic action of phenol for aquatic environment is well known. In this study, rapid phenol toxicity tests (1 h) were developed based on chlorophyll a (Chl a) fluorescence and the movement parameters of the freshwater flagellate, Euglena agilis Carter. Phenol significantly reduced the maximum quantum yield (F v /F m ) of photosystem II (PS II) and the maximum photosynthetic electron transport rate (rETR max ) with median effective concentration (EC 50 ) values of 8.94 and 4.67 mM, respectively. Phenol reduced the motility and triggered change in the swimming velocity of the test organism. Among the parameters tested, velocity was the most sensitive biomarker with an EC 50 of 3.17 mM. The EC 50 values for F v /F m , motility, and velocity appear to overlap the permitted levels of phenol. In conclusion, the photosynthesis and movement of E. agilis can be fast and sensitive risk assessment parameters for the evaluation of phenol toxicity in municipal and industrial effluents

  14. How Rapid is Rapid Prototyping? Analysis of ESPADON Programme Results

    Directory of Open Access Journals (Sweden)

    Ian D. Alston

    2003-05-01

    Full Text Available New methodologies, engineering processes, and support environments are beginning to emerge for embedded signal processing systems. The main objectives are to enable defence industry to field state-of-the-art products in less time and with lower costs, including retrofits and upgrades, based predominately on commercial off the shelf (COTS components and the model-year concept. One of the cornerstones of the new methodologies is the concept of rapid prototyping. This is the ability to rapidly and seamlessly move from functional design to the architectural design to the implementation, through automatic code generation tools, onto real-time COTS test beds. In this paper, we try to quantify the term “rapid” and provide results, the metrics, from two independent benchmarks, a radar and sonar beamforming application subset. The metrics show that the rapid prototyping process may be sixteen times faster than a conventional process.

  15. A rapid radioimmunoassay for insulin suitable for testing pancreatic tissue prior to transplantation

    International Nuclear Information System (INIS)

    Besch, W.; Kohnert, K.-D.; Hahn, H.-J.; Ziegler, M.; Lorenz, D.

    1984-01-01

    One way of diabetes mellitus treatment is the transplantation of insulin-producing tissue. As islet or pancreas transplantation has made progress, testing of the tissue for its vitality, insulin content and insulin secretory response prior to transplantation became necessary. Apart from problems of rejection of allografted tissue, improvement of the patients metabolic control partly depends on the insulin content of the tissue transplanted. It was the aim of the present work to establish a radioimmunoassay which ensures rapid determination of immunoreactive insulin concentrations (IRI) either intracellularly-stored or released upon stimulation of human pancreas or islet with glucose, and to demonstrate the useful application of this assay for the assessment of transplantable tissue. (Auth.)

  16. A standard screening test for the early and rapid diagnosis of leptospirosis

    Directory of Open Access Journals (Sweden)

    Chandrasekaran S

    2004-01-01

    Full Text Available PURPOSE : To perform dark field microscopy (DFM for detection of Leptospira and to validate the results using Leptospira IgM antibody SERION ELISA test. METHODS : After differential centrifugation of Ruys, DFM was done to demonstrate Leptospira in the blood and SERION ELISA was done for Leptospira IgM antibody in single or paired serum samples. One hundred and eleven cases (39 adults and 72 children of suspected leptospirosis were included in the study. RESULTS : Anicteric cases accounted for 66.7% (26/39 of adults and complications involving brain, liver, kidney and eyes were seen in 33.3% (13/39. In children, 90.3% (65/72 were anicteric and involvement of brain and liver was seen in 9.7% (7/72 cases. On testing 60 single samples of blood from 23 adults and 37 children, DFM exhibited greater sensitivity of 93.3% (56/60 than that of SERION ELISA for Leptospira IgM antibody (33.3%, 20/60. It was observed that the positivity of DFM decreased from 100% (15/15 to 90.9% (10/11 with increase in the duration of infection for more than one week. ELISA for Leptospira IgM, done on 51 paired blood samples, was positive in 64.7% (33/51 cases when both (first and second samples were tested while in 45.1% (23/51 cases was positive with first sample alone. 58.8%(30/51 cases were positive by testing second sample. DFM results on paired blood samples showed persistence of Leptospira in 92.9% of cases. CONCLUSION : This study shows the validation of DFM results by SERION ELISA for Leptospira IgM antibody, based on which we recommend that DFM can serve as a standard screening test for early and rapid diagnosis of leptospirosis.

  17. Rapid diagnostic tests as a source of DNA for Plasmodium species-specific real-time PCR

    Directory of Open Access Journals (Sweden)

    Van Esbroeck Marjan

    2011-03-01

    Full Text Available Abstract Background This study describes the use of malaria rapid diagnostic tests (RDTs as a source of DNA for Plasmodium species-specific real-time PCR. Methods First, the best method to recover DNA from RDTs was investigated and then the applicability of this DNA extraction method was assessed on 12 different RDT brands. Finally, two RDT brands (OptiMAL Rapid Malaria Test and SDFK60 malaria Ag Plasmodium falciparum/Pan test were comprehensively evaluated on a panel of clinical samples submitted for routine malaria diagnosis at ITM. DNA amplification was done with the 18S rRNA real-time PCR targeting the four Plasmodium species. Results of PCR on RDT were compared to those obtained by PCR on whole blood samples. Results Best results were obtained by isolating DNA from the proximal part of the nitrocellulose component of the RDT strip with a simple DNA elution method. The PCR on RDT showed a detection limit of 0.02 asexual parasites/μl, which was identical to the same PCR on whole blood. For all 12 RDT brands tested, DNA was detected except for one brand when a low parasite density sample was applied. In RDTs with a plastic seal covering the nitrocellulose strip, DNA extraction was hampered. PCR analysis on clinical RDT samples demonstrated correct identification for single species infections for all RDT samples with asexual parasites of P. falciparum (n = 60, Plasmodium vivax (n = 10, Plasmodium ovale (n = 10 and Plasmodium malariae (n = 10. Samples with only gametocytes were detected in all OptiMAL and in 10 of the 11 SDFK60 tests. None of the negative samples (n = 20 gave a signal by PCR on RDT. With PCR on RDT, higher Ct-values were observed than with PCR on whole blood, with a mean difference of 2.68 for OptiMAL and 3.53 for SDFK60. Mixed infections were correctly identified with PCR on RDT in 4/5 OptiMAL tests and 2/5 SDFK60 tests. Conclusions RDTs are a reliable source of DNA for Plasmodium real-time PCR. This study demonstrates the

  18. Possible Biochemical Markers in Protein-Energy Malnutrition and ...

    African Journals Online (AJOL)

    This study was carried out to determine possible biochemical markers in children suffering from Plasmodium falciparum malaria and Protein-Energy Malnutrition in a Hospital setting in Western Kenya. Spectrophotometric assays of selected biochemical parameters namely, albumin, total proteins, glucose, glutamate ...

  19. Bacterial Cytological Profiling (BCP as a Rapid and Accurate Antimicrobial Susceptibility Testing Method for Staphylococcus aureus

    Directory of Open Access Journals (Sweden)

    D.T. Quach

    2016-02-01

    Full Text Available Successful treatment of bacterial infections requires the timely administration of appropriate antimicrobial therapy. The failure to initiate the correct therapy in a timely fashion results in poor clinical outcomes, longer hospital stays, and higher medical costs. Current approaches to antibiotic susceptibility testing of cultured pathogens have key limitations ranging from long run times to dependence on prior knowledge of genetic mechanisms of resistance. We have developed a rapid antimicrobial susceptibility assay for Staphylococcus aureus based on bacterial cytological profiling (BCP, which uses quantitative fluorescence microscopy to measure antibiotic induced changes in cellular architecture. BCP discriminated between methicillin-susceptible (MSSA and -resistant (MRSA clinical isolates of S. aureus (n = 71 within 1–2 h with 100% accuracy. Similarly, BCP correctly distinguished daptomycin susceptible (DS from daptomycin non-susceptible (DNS S. aureus strains (n = 20 within 30 min. Among MRSA isolates, BCP further identified two classes of strains that differ in their susceptibility to specific combinations of beta-lactam antibiotics. BCP provides a rapid and flexible alternative to gene-based susceptibility testing methods for S. aureus, and should be readily adaptable to different antibiotics and bacterial species as new mechanisms of resistance or multidrug-resistant pathogens evolve and appear in mainstream clinical practice.

  20. Adolescents' experience of a rapid HIV self-testing device in youth-friendly clinic settings in Cape Town South Africa: a cross-sectional community based usability study.

    Science.gov (United States)

    Smith, Philip; Wallace, Melissa; Bekker, Linda-Gail

    2016-12-23

    Introduction : Since HIV testing in South African adolescents and young adults is sub-optimal, the objective of the current study was to investigate the feasibility and acceptability of an HIV rapid self-testing device in adolescents and young people at the Desmond Tutu HIV Foundation Youth Centre and Mobile Clinic. Methods : Self-presenting adolescents and young adults were invited to participate in a study investigating the fidelity, usability and acceptability of the AtomoRapid HIV Rapid self-testing device. Trained healthcare workers trained participants to use the device before the participant conducted the HIV self-test with device usage instructions. The healthcare worker then conducted a questionnaire-based survey to assess outcomes. Results : Of the 224 enrolled participants between 16 and 24 years of age, 155 (69,2%) were female. Overall, fidelity was high; 216 (96,4%) participants correctly completed the test and correctly read and interpreted the HIV test result. There were eight (3,6%) user errors overall; six participants failed to prick their finger even though the lancet fired correctly. There were two user errors where participants failed to use the capillary tube correctly. Participants rated acceptability and usability highly, with debut testers giving significantly higher ratings for both. Younger participants gave significantly higher ratings of acceptability. Conclusions : Adolescents and young adults found HIV self-testing highly acceptable with the AtomoRapid and they used the device accurately. Further research should investigate how, where and when to deploy HIV self-testing as a means to accompany existing strategies in reaching the UNAIDS goal to test 90% of all individuals worldwide.

  1. When rapid adaptation paradigm is not too rapid: Evidence of face-sensitive N170 adaptation effects.

    Science.gov (United States)

    Tian, Tengxiang; Feng, Xue; Feng, Chunliang; Gu, Ruolei; Luo, Yue-Jia

    2015-07-01

    Recent findings have demonstrated that N170 adaptation effects evoked by face adaptors are general to face and non-face tests, implicating adaptor-locked interferences in the rapid adaptation paradigm. Here we examined the extent to which adaptor-locked interferences confound N170 adaptation effects in different experimental parameters by manipulating the stimulus onset asynchrony (SOA) duration and jitter between adaptors and tests. In the short SOA, those interferences were well visible for the grand-average ERP waveforms evoked by tests, and they are likely to render rapid adaptation paradigm with short SOA unreliable. The adaptor-locked interferences were attenuated by appropriately increasing SOA duration, such that face-sensitive adaptation effects were evident in the long SOA for both baseline-to-peak and peak-to-peak N170 measurements. These findings suggest that the rapid adaptation paradigm may work with a relative long SOA. Our findings provide useful information for future studies regarding the choosing of appropriate experimental parameters and measurements for the rapid adaptation paradigm. In addition, future studies are needed to investigate how to objectively subtract the overlaps of adaptors from tests and to validate the N170 adaptation effect with appropriate behavioral performance. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. A Laboratory-Based Evaluation of Four Rapid Point-of-Care Tests for Syphilis

    Science.gov (United States)

    Causer, Louise M.; Kaldor, John M.; Fairley, Christopher K.; Donovan, Basil; Karapanagiotidis, Theo; Leslie, David E.; Robertson, Peter W.; McNulty, Anna M.; Anderson, David; Wand, Handan; Conway, Damian P.; Denham, Ian; Ryan, Claire; Guy, Rebecca J.

    2014-01-01

    Background Syphilis point-of-care tests may reduce morbidity and ongoing transmission by increasing the proportion of people rapidly treated. Syphilis stage and co-infection with HIV may influence test performance. We evaluated four commercially available syphilis point-of-care devices in a head-to-head comparison using sera from laboratories in Australia. Methods Point-of-care tests were evaluated using sera stored at Sydney and Melbourne laboratories. Sensitivity and specificity were calculated by standard methods, comparing point-of-care results to treponemal immunoassay (IA) reference test results. Additional analyses by clinical syphilis stage, HIV status, and non-treponemal antibody titre were performed. Non-overlapping 95% confidence intervals (CI) were considered statistically significant differences in estimates. Results In total 1203 specimens were tested (736 IA-reactive, 467 IA-nonreactive). Point-of-care test sensitivities were: Determine 97.3%(95%CI:95.8–98.3), Onsite 92.5%(90.3–94.3), DPP 89.8%(87.3–91.9) and Bioline 87.8%(85.1–90.0). Specificities were: Determine 96.4%(94.1–97.8), Onsite 92.5%(90.3–94.3), DPP 98.3%(96.5–99.2), and Bioline 98.5%(96.8–99.3). Sensitivity of the Determine test was 100% for primary and 100% for secondary syphilis. The three other tests had reduced sensitivity among primary (80.4–90.2%) compared to secondary syphilis (94.3–98.6%). No significant differences in sensitivity were observed by HIV status. Test sensitivities were significantly higher among high-RPR titre (RPR≥8) (range: 94.6–99.5%) than RPR non-reactive infections (range: 76.3–92.9%). Conclusions The Determine test had the highest sensitivity overall. All tests were most sensitive among high-RPR titre infections. Point-of-care tests have a role in syphilis control programs however in developed countries with established laboratory infrastructures, the lower sensitivities of some tests observed in primary syphilis suggest these would

  3. Possibilities and methods for biochemical assessment of radiation injury

    Energy Technology Data Exchange (ETDEWEB)

    Minkova, M [Meditsinska Akademiya, Sofia (Bulgaria). Nauchen Inst. po Rentgenologiya i Radiobiologiya

    1986-01-01

    An extensitive review (77 references) is made of the application of biochemical diagnostic methods for assessment of radiation diseases. A brief characteristics of several biochemical indicators is given: deoxycytidine, thymidine, rho-aminoisocarboxylic acid, DNA-ase, nucleic acids. Influence of such factors as age, sex, season etc. is studied by means of functional biochemical indicators as: creatine, triptophanic metabolites, 5-hydroxy-indolacetic acid, biogenic amines, serum proteins, enzymes, etc.

  4. Operational evaluation of rapid diagnostic testing for Ebola Virus Disease in Guinean laboratories.

    Directory of Open Access Journals (Sweden)

    Amanda VanSteelandt

    Full Text Available Rapid Diagnostic Tests (RDTs for Ebola Virus Disease (EVD at the point of care have the potential to increase access and acceptability of EVD testing and the speed of patient isolation and secure burials for suspect cases. A pilot program for EVD RDTs in high risk areas of Guinea was introduced in October 2015. This paper presents concordance data between EVD RDTs and PCR testing in the field as well as an assessment of the acceptability, feasibility, and quality assurance of the RDT program.Concordance data were compiled from laboratory surveillance databases. The operational measures of the laboratory-based EVD RDT program were evaluated at all 34 sentinel sites in Guinea through: (1 a technical questionnaire filled by the lab technicians who performed the RDTs, (2 a checklist filled by the evaluator during the site visits, and (3 direct observation of the lab technicians performing the quality control test. Acceptability of the EVD RDT was good for technicians, patients, and families although many technicians (69.8% expressed concern for their safety while performing the test. The feasibility of the program was good based on average technician knowledge scores (6.6 out of 8 but basic infrastructure, equipment, and supplies were lacking. There was much room for improvement in quality assurance of the program.The implementation of new diagnostics in weak laboratory systems requires general training in quality assurance, biosafety and communication with patients in addition to specific training for the new test. Corresponding capacity building in terms of basic equipment and a long-term commitment to transfer supervision and quality improvement to national public health staff are necessary for successful implementation.

  5. Direct Fibrinolytic Snake Venom Metalloproteinases Affecting Hemostasis: Structural, Biochemical Features and Therapeutic Potential.

    Science.gov (United States)

    Sanchez, Eladio F; Flores-Ortiz, Renzo J; Alvarenga, Valeria G; Eble, Johannes A

    2017-12-05

    Snake venom metalloproteinases (SVMPs) are predominant in viperid venoms, which provoke hemorrhage and affect hemostasis and thrombosis. P-I class enzymes consist only of a single metalloproteinase domain. Despite sharing high sequence homology, only some of them induce hemorrhage. They have direct fibrin(ogen)olytic activity. Their main biological substrate is fibrin(ogen), whose Aα-chain is degraded rapidly and independently of activation of plasminogen. It is important to understand their biochemical and physiological mechanisms, as well as their applications, to study the etiology of some human diseases and to identify sites of potential intervention. As compared to all current antiplatelet therapies to treat cardiovascular events, the SVMPs have outstanding biochemical attributes: (a) they are insensitive to plasma serine proteinase inhibitors; (b) they have the potential to avoid bleeding risk; (c) mechanistically, they are inactivated/cleared by α2-macroglobulin that limits their range of action in circulation; and (d) few of them also impair platelet aggregation that represent an important target for therapeutic intervention. This review will briefly highlight the structure-function relationships of these few direct-acting fibrinolytic agents, including, barnettlysin-I, isolated from Bothrops barnetti venom, that could be considered as potential agent to treat major thrombotic disorders. Some of their pharmacological advantages are compared with plasmin.

  6. Direct Fibrinolytic Snake Venom Metalloproteinases Affecting Hemostasis: Structural, Biochemical Features and Therapeutic Potential

    Directory of Open Access Journals (Sweden)

    Eladio F. Sanchez

    2017-12-01

    Full Text Available Snake venom metalloproteinases (SVMPs are predominant in viperid venoms, which provoke hemorrhage and affect hemostasis and thrombosis. P-I class enzymes consist only of a single metalloproteinase domain. Despite sharing high sequence homology, only some of them induce hemorrhage. They have direct fibrin(ogenolytic activity. Their main biological substrate is fibrin(ogen, whose Aα-chain is degraded rapidly and independently of activation of plasminogen. It is important to understand their biochemical and physiological mechanisms, as well as their applications, to study the etiology of some human diseases and to identify sites of potential intervention. As compared to all current antiplatelet therapies to treat cardiovascular events, the SVMPs have outstanding biochemical attributes: (a they are insensitive to plasma serine proteinase inhibitors; (b they have the potential to avoid bleeding risk; (c mechanistically, they are inactivated/cleared by α2-macroglobulin that limits their range of action in circulation; and (d few of them also impair platelet aggregation that represent an important target for therapeutic intervention. This review will briefly highlight the structure–function relationships of these few direct-acting fibrinolytic agents, including, barnettlysin-I, isolated from Bothrops barnetti venom, that could be considered as potential agent to treat major thrombotic disorders. Some of their pharmacological advantages are compared with plasmin.

  7. Comparison of amrad ICT test with microscopic examination for rapid diagnosis of malaria

    International Nuclear Information System (INIS)

    Rahim, F.; Amin-ul-Haq; Jamal, S.

    2002-01-01

    Objective: To assess the sensitivity and specificity of an alternate and easy technique to diagnose malaria. Design: A prospective study. Place and Duration of Study: Department of pathology, DHQ Hospital, Timergara District, Dir, North-west Frontier Province of Pakistan, from 19th September to 5th October 2000. Subjects and Methods: Smear positive 50 patients (27 males and 23 females, age ranging 2 years to 70 years) were included. Thick and thin smears were stained with Giemsa's stain and examined by the principal author. The ICT malaria test was performed according to the instruction sheet of the manufacturer. Results: on microscopy there were 29 cases of Plasmodium falciparum (P.f) and 21 of Plasmodiium vivax (P.v.). On ICT malaria P.f/P.v, there were 29 samples positive for P. Falciparum and 17 for P. vivax. These results demonstrated that the ICT malaria P.f/P.v test had sensitivity of 100% for P. falciparum and 81% for P. vivax and specificity of 100% for both, when compared to traditional blood films for the detection of P. vivax and P. falciparum malaria. Conclusion: The ICT malaria P.f/P.v test is an effective tool for the rapid diagnosis of malaria and may be used as a first line diagnostic tool. (author)

  8. Monitoring people at risk of drinking by a rapid urinary ethyl glucuronide test

    Directory of Open Access Journals (Sweden)

    Fucci Nadia

    2017-12-01

    Full Text Available Alcohol and illicit drug abuse are major public health problems worldwide. Since alcohol is the predominant substance of choice in polydrug abusers, monitoring its use, along with urinary drug screening in patients in rehabilitation programs, appeared to be crucial in identifying patients at risk of alcohol disorders leading to impaired quality of life. Ethyl β-D-6-glucuronide, a non-oxidative, non-volatile, stable and minor direct ethanol metabolite, has a 6h to 4 day window of detection in urine after the last alcohol intake. Each of the 119 subjects (85 males, 34 females registered with the Public Health Service for Drug Dependence Treatment provided a urine sample for ethylglucoronide (EtG determination in an immunochemical test with a 500 ng/ml cutoff. All results were evaluated with confirmation criteria of a fully validated gas chromatography/mass spectrometry assay. The diagnostic performance of the EtG immunochemical test was assessed using Receiver Operating Characteristic Curve analysis. The immunochemical test specificity was 100% for EtG urinary values above 500 ng/ml. No false positive results were found. With levels below 500 ng/ml, 12% of the samples were classified as negative. The average consumption of the incorrectly classified subjects was 171 ng/ml, with a misclassification error of 6.5% to 18.5%. High agreement between EtG as determined in an immunochemical test and gas chromatography/mass spectrometry, suggests that the rapid EtG test is a reliable, cost-effective alcohol monitoring assay for patient management in many non-forensic settings, such as drug rehabilitation programs.

  9. Evaluation of a rapid diagnostic test for yaws infection in a community surveillance setting.

    Directory of Open Access Journals (Sweden)

    Michael Marks

    2014-09-01

    Full Text Available Yaws is a non-venereal treponemal infection caused by Treponema pallidum ssp. pertenue. The WHO has launched a worldwide control programme, which aims to eradicate yaws by 2020. The development of a rapid diagnostic test (RDT for serological diagnosis in the isolated communities affected by yaws is a key requirement for the successful implementation of the WHO strategy. We conducted a study to evaluate the utility of the DPP test in screening for yaws, utilizing samples collected as part of a community prevalence survey conducted in the Solomon Islands. 415 serum samples were tested using both traditional syphilis serology (TPPA and quantitative RPR and the Chembio DPP Syphilis Screen and Confirm RDT. We calculated the sensitivity and specificity of the RDT as compared to gold standard serology. The sensitivity of the RDT against TPPA was 58.5% and the specificity was 97.6%. The sensitivity of the RDT against RPR was 41.7% and the specificity was 95.2%. The sensitivity of the DPP was strongly related to the RPR titre with a sensitivity of 92.0% for an RPR titre of >1/16. Wider access to DPP testing would improve our understanding of worldwide yaws case reporting and the test may play a key role in assessing patients presenting with yaws like lesions in a post-mass drug administration (MDA setting.

  10. Interferon-β treatment associated with a biochemical profile suggestive of acromegaly. A case report of a patient treated for multiple sclerosis

    DEFF Research Database (Denmark)

    Andreassen, Mikkel; Frystyk, Jan; Miller, Karen K

    2010-01-01

    We describe a 34-year-old female treated with IFN-ß for 8 years with a biochemical profile suggestive of acromegaly. The patient presented with elevated serum insulin-like growth factor-I (IGF-I) and insufficient suppression of growth hormone (GH) during oral glucose tolerance test (OGTT). There ......-I. In conclusion, IFN-ß treatment mimicked acromegaly biochemically. The changes were partially reversible....

  11. Interferon-β treatment associated with a biochemical profile suggestive of acromegaly. A case report of a patient treated for multiple sclerosis

    DEFF Research Database (Denmark)

    Andreassen, Mikkel; Frystyk, Jan; Miller, Karen K

    2010-01-01

    We describe a 34-year-old female treated with IFN-β for 8 years with a biochemical profile suggestive of acromegaly. The patient presented with elevated serum insulin-like growth factor-I (IGF-I) and insufficient suppression of growth hormone (GH) during oral glucose tolerance test (OGTT). There ......-I. In conclusion, IFN-β treatment mimicked acromegaly biochemically. The changes were partially reversible....

  12. Test and User Facilities | NREL

    Science.gov (United States)

    Test and User Facilities Test and User Facilities Our test and user facilities are available to | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z B Battery Thermal and Life Test Facility Biochemical Conversion Pilot Plant C Controllable Grid Interface Test System D Dynamometer Test Facilities

  13. Haematological and blood biochemical indices of West African ...

    African Journals Online (AJOL)

    Haematological and blood biochemical indices of West African dwarf goats vaccinated against Pestes des petit ruminants (PPR) ... blood biochemical indices of forty randomly selected West African dwarf (WAD) goats were studied. Packed cell volume ... neutrophil/lymphocyte ratio and white blood cells (WBC) than females.

  14. BioNessie - a grid enabled biochemical networks simulation environment

    OpenAIRE

    Liu, X.; Jiang, J.; Ajayi, O.; Gu, X.; Gilbert, D.; Sinnott, R.O.

    2008-01-01

    The simulation of biochemical networks provides insight and understanding about the underlying biochemical processes and pathways used by cells and organisms. BioNessie is a biochemical network simulator which has been developed at the University of Glasgow. This paper describes the simulator and focuses in particular on how it has been extended to benefit from a wide variety of high performance compute resources across the UK through Grid technologies to support larger scale simulations.

  15. How the concept of biochemical response influenced the management of primary biliary cholangitis over time

    NARCIS (Netherlands)

    Lammers, W. J.; Leeman, M.; Ponsioen, C. I. J.; Boonstra, K.; van Erpecum, K. J.; Wolfhagen, F. H. J.; Kuyvenhoven, J. Ph; Vrolijk, J. M.; Drenth, J. P. H.; Witteman, E. M.; van Nieuwkerk, C. M. J.; van der Spek, B. W.; Witteman, B. J. M.; Erkelens, G. W.; Verhagen, M. A. M. T.; van Tuyl, S. A. C.; Poen, A. C.; Brouwer, J. T.; ter Borg, F.; Koek, G. H.; van Ditzhuijsen, T. J. M.; Hansen, B. E.; van Buuren, H. R.

    2016-01-01

    Criteria assessing biochemical response to ursodeoxycholic acid (UDCA) are established risk stratification tools in primary biliary cholangitis (PBC). We aimed to evaluate to what extent liver tests influenced patient management during a three decade period, and whether this changed over time. 851

  16. Economic impact of rapid diagnostic methods in Clinical Microbiology: Price of the test or overall clinical impact.

    Science.gov (United States)

    Cantón, Rafael; Gómez G de la Pedrosa, Elia

    2017-12-01

    The need to reduce the time it takes to establish a microbiological diagnosis and the emergence of new molecular microbiology and proteomic technologies has fuelled the development of rapid and point-of-care techniques, as well as the so-called point-of-care laboratories. These laboratories are responsible for conducting both techniques partially to response to the outsourcing of the conventional hospital laboratories. Their introduction has not always been accompanied with economic studies that address their cost-effectiveness, cost-benefit and cost-utility, but rather tend to be limited to the unit price of the test. The latter, influenced by the purchase procedure, does not usually have a regulated reference value in the same way that medicines do. The cost-effectiveness studies that have recently been conducted on mass spectrometry in the diagnosis of bacteraemia and the use of antimicrobials have had the greatest clinical impact and may act as a model for future economic studies on rapid and point-of-care tests. Copyright © 2017 Elsevier España, S.L.U. and Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.

  17. Introducing rapid diagnostic tests for malaria into registered drug shops in Uganda

    DEFF Research Database (Denmark)

    Mbonye, Anthony K; Clarke, Sîan E; Lal, Sham

    2015-01-01

    BACKGROUND: Malaria is a major public health problem in Uganda and the current policy recommends introduction of rapid diagnostic tests for malaria (RDTs) to facilitate effective case management. However, provision of RDTs in drug shops potentially raises a new set of issues, such as adherence...... to RDTs results, management of severe illnesses, referral of patients, and relationship with caretakers. The main objective of the study was to examine the impact of introducing RDTs in registered drug shops in Uganda and document lessons and policy implications for future scale-up of malaria control...... in the private health sector. METHODS: A cluster-randomized trial introducing RDTs into registered drug shops was implemented in central Uganda from October 2010 to July 2012. An evaluation was undertaken to assess the impact and the processes involved with the introduction of RDTs into drug shops, the lessons...

  18. Cost-effectiveness of malaria microscopy and rapid diagnostic tests versus presumptive diagnosis

    DEFF Research Database (Denmark)

    Batwala, Vincent; Magnussen, Pascal; Hansen, Kristian Schultz

    2011-01-01

    .9) than in low transmission setting (US$1.78). At a willingness to pay of US$2.8, RDT remained cost effective up to a threshold value of the cost of treatment of US$4.7. CONCLUSION: RDT was cost effective in both low and high transmission settings. With a global campaign to reduce the costs of AL and RDT......ABSTRACT: BACKGROUND: Current Uganda National Malaria treatment guidelines recommend parasitological confirmation either by microscopy or rapid diagnostic test (RDT) before treatment with artemether-lumefantrine (AL). However, the cost-effectiveness of these strategies has not been assessed...... departments were enrolled from March 2010 to February 2011. Of these, a random sample of 1,627 was selected to measure additional socio-economic characteristics. Costing was performed following the standard step-down cost allocation and the ingredients approach. Effectiveness was measured as the number...

  19. The predictive value of 2-year posttreatment biopsy after prostate cancer radiotherapy for eventual biochemical outcome

    International Nuclear Information System (INIS)

    Vance, Waseet; Tucker, Susan L.; Crevoisier, Renaud de; Kuban, Deborah A.; Cheung, M. Rex

    2007-01-01

    Purpose: To determine the value of a 2-year post-radiotherapy (RT) prostate biopsy for predicting eventual biochemical failure in patients who were treated for localized prostate cancer. Methods and Materials: This study comprised 164 patients who underwent a planned 2-year post-RT prostate biopsy. The independent prognostic value of the biopsy results for forecasting eventual biochemical outcome and overall survival was tested with other factors (the Gleason score, 1992 American Joint Committee on Cancer tumor stage, pretreatment prostate-specific antigen level, risk group, and RT dose) in a multivariate analysis. The current nadir + 2 (CN + 2) definition of biochemical failure was used. Patients with rising prostate-specific antigen (PSA) or suspicious digital rectal examination before the biopsy were excluded. Results: The biopsy results were normal in 78 patients, scant atypical and malignant cells in 30, carcinoma with treatment effect in 43, and carcinoma without treatment effect in 13. Using the CN + 2 definition, we found a significant association between biopsy results and eventual biochemical failure. We also found that the biopsy status provides predictive information independent of the PSA status at the time of biopsy. Conclusion: A 2-year post-RT prostate biopsy may be useful for forecasting CN + 2 biochemical failure. Posttreatment prostate biopsy may be useful for identifying patients for aggressive salvage therapy

  20. Rapid and point-of-care tests for the diagnosis of Trichomonas vaginalis in women and men.

    Science.gov (United States)

    Gaydos, Charlotte A; Klausner, Jeffrey D; Pai, Nitika Pant; Kelly, Helen; Coltart, Cordelia; Peeling, Rosanna W

    2017-12-01

    Trichomonasvaginalis (TV) is a highly prevalent parasitic infection worldwide. It is associated with many adverse reproductive health outcomes. Many infections are asymptomatic and syndromic management leads to underdetection of TV. Traditional methods of TV detection such as wet preparation are insensitive. New rapid, point-of-care (POC) tests can enhance the diagnosis of trichomoniasis. The authors reviewed the literature and discuss older POC tests for TV detection, as well as the OSOM lateral flow test, the AmpliVue test, the Solana test and the GeneXpert test as well as the limitations of wet preparation and culture for detection of TV. The OSOM test is easy to perform, compared with other POC tests, and is Clinical Laboratory Improvement Amendments (CLIA)-waived, equipment-free, has sensitivities of 83%-86% compared with nucleic acid amplification tests (NAATs) and can be performed in 15 min. The AmpliVue and the Solana tests are not CLIA waived and require small pieces of equipment. They are molecular amplified assays and can be completed in TV test for women and men is a moderately complex test, requires a small platform and can be performed in women and one is available for detection of TV in men. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  1. Portable Diagnostics and Rapid Germination

    Energy Technology Data Exchange (ETDEWEB)

    Dunn, Zachary Spencer [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-12-01

    In the Bioenergy and Defense Department of Sandia National Laboratories, characterization of the BaDx (Bacillus anthracis diagnostic cartridge) was performed and rapid germination chemistry was investigated. BaDx was tested with complex sample matrixes inoculated with Bacillus anthracis, and the trials proved that BaDx will detect Bacillus anthracis in a variety of the medium, such as dirt, serum, blood, milk, and horse fluids. The dimensions of the device were altered to accommodate an E. coli or Listeria lateral flow immunoassay, and using a laser printer, BaDx devices were manufactured to identify E. coli and Listeria. Initial testing with E. coli versions of BaDx indicate that the device will be viable as a portable diagnostic cartridge. The device would be more effective with faster bacteria germination; hence studies were performed the use of rapid germination chemistry. Trials with calcium dipicolinic acid displayed increased cell germination, as shown by control studies using a microplate reader. Upon lyophilization the rapid germination chemistry failed to change growth patterns, indicating that the calcium dipicolinic acid was not solubilized under the conditions tested. Although incompatible with the portable diagnostic device, the experiments proved that the rapid germination chemistry was effective in increasing cell germination.

  2. Definitions of biochemical failure in prostate cancer following radiation therapy

    International Nuclear Information System (INIS)

    Taylor, Jeremy M.G.; Griffith, Kent A.; Sandler, Howard M.

    2001-01-01

    Purpose: The American Society for Therapeutic Radiology and Oncology (ASTRO) published a consensus panel definition of biochemical failure following radiation therapy for prostate cancer. In this paper, we develop a series of alternative definitions of biochemical failure. Using data from 688 patients, we evaluated the sensitivity and specificity of the various definitions, with respect to a defined 'clinically meaningful' outcome. Methods and Materials: The ASTRO definition of biochemical failure requires 3 consecutive rises in prostate-specific antigen (PSA). We considered several modifications to the standard definition: to require PSA rises of a certain magnitude, to consider 2 instead of 3 rises, to require the final PSA value to be greater than a fixed cutoff level, and to define biochemical failure based on the slope of PSA over 1, 1.5, or 2 years. A clinically meaningful failure is defined as local recurrence, distant metastases, initiation of unplanned hormonal therapy, unplanned radical prostatectomy, or a PSA>25 later than 6 months after radiation. Results: Requiring the final PSA in a series of consecutive rises to be larger than 1.5 ng/mL increased the specificity of biochemical failure. For a fixed specificity, defining biochemical failure based on 2 consecutive rises, or the slope over the last year, could increase the sensitivity by up to approximately 20%, compared to the ASTRO definition. Using a rule based on the slope over the previous year or 2 rises leads to a slightly earlier detection of biochemical failure than does the ASTRO definition. Even with the best rule, only approximately 20% of true failures are biochemically detected more than 1 year before the clinically meaningful event time. Conclusion: There is potential for improvement in the ASTRO consensus definition of biochemical failure. Further research is needed, in studies with long follow-up times, to evaluate the relationship between various definitions of biochemical failure and

  3. Flow Type Bio-Chemical Calorimeter with Micro Differential Thermopile Sensor.

    Science.gov (United States)

    Saito, Masataka; Nakabeppu, Osamu

    2015-04-01

    Bio-chemical calorimeters with a MEMS (Micro-Electro-Mechanical Systems) thermopile sensor have been studied for monitoring detailed processes of the biochemical reactions of a minute sample with a high temporal resolution. The bio-calorimeters are generally divided into a batch-type and a flow-type. We developed a highly sensitive batch-type calorimeter which can detect a 100 nW level thermal reaction. However it shows a long settling time of 2 hours because of the heat capacity of a whole calorimeter. Thus, the flow-type calorimeters in passive and active mode have been studied for measuring the thermal reactions in an early stage after starting an analysis. The flow-type calorimeter consists of the MEMS differential thermopile sensor, a pair of micro channel reactor in a PDMS (polydimethylsiloxane) sheet in a three-fold thermostat chamber. The calorimeter in the passive mode was tested with dilution reactions of ethanol to water and NaCl aqueous solution to water. It was shown that the calorimeter detects exo- and endothermic reaction over 250 nW at solution flow rate of 0.05 ~ 1 µl/min with a settling time of about 4 minutes. In the active mode, a response test was conducted by using heat removal by water flow from the reactor channel. The active calorimetry enhances the response time about three to four times faster.

  4. Clinical and taxonomic status of pathogenic nonpigmented or late-pigmenting rapidly growing mycobacteria.

    Science.gov (United States)

    Brown-Elliott, Barbara A; Wallace, Richard J

    2002-10-01

    The history, taxonomy, geographic distribution, clinical disease, and therapy of the pathogenic nonpigmented or late-pigmenting rapidly growing mycobacteria (RGM) are reviewed. Community-acquired disease and health care-associated disease are highlighted for each species. The latter grouping includes health care-associated outbreaks and pseudo-outbreaks as well as sporadic disease cases. Treatment recommendations for each species and type of disease are also described. Special emphasis is on the Mycobacterium fortuitum group, including M. fortuitum, M. peregrinum, and the unnamed third biovariant complex with its recent taxonomic changes and newly recognized species (including M. septicum, M. mageritense, and proposed species M. houstonense and M. bonickei). The clinical and taxonomic status of M. chelonae, M. abscessus, and M. mucogenicum is also detailed, along with that of the closely related new species, M. immunogenum. Additionally, newly recognized species, M. wolinskyi and M. goodii, as well as M. smegmatis sensu stricto, are included in a discussion of the M. smegmatis group. Laboratory diagnosis of RGM using phenotypic methods such as biochemical testing and high-performance liquid chromatography and molecular methods of diagnosis are also discussed. The latter includes PCR-restriction fragment length polymorphism analysis, hybridization, ribotyping, and sequence analysis. Susceptibility testing and antibiotic susceptibility patterns of the RGM are also annotated, along with the current recommendations from the National Committee for Clinical Laboratory Standards (NCCLS) for mycobacterial susceptibility testing.

  5. CUSUM-Logistic Regression analysis for the rapid detection of errors in clinical laboratory test results.

    Science.gov (United States)

    Sampson, Maureen L; Gounden, Verena; van Deventer, Hendrik E; Remaley, Alan T

    2016-02-01

    The main drawback of the periodic analysis of quality control (QC) material is that test performance is not monitored in time periods between QC analyses, potentially leading to the reporting of faulty test results. The objective of this study was to develop a patient based QC procedure for the more timely detection of test errors. Results from a Chem-14 panel measured on the Beckman LX20 analyzer were used to develop the model. Each test result was predicted from the other 13 members of the panel by multiple regression, which resulted in correlation coefficients between the predicted and measured result of >0.7 for 8 of the 14 tests. A logistic regression model, which utilized the measured test result, the predicted test result, the day of the week and time of day, was then developed for predicting test errors. The output of the logistic regression was tallied by a daily CUSUM approach and used to predict test errors, with a fixed specificity of 90%. The mean average run length (ARL) before error detection by CUSUM-Logistic Regression (CSLR) was 20 with a mean sensitivity of 97%, which was considerably shorter than the mean ARL of 53 (sensitivity 87.5%) for a simple prediction model that only used the measured result for error detection. A CUSUM-Logistic Regression analysis of patient laboratory data can be an effective approach for the rapid and sensitive detection of clinical laboratory errors. Published by Elsevier Inc.

  6. A Rapid Blood Test To Determine the Active Status and Duration of Acute Viral Infection.

    Science.gov (United States)

    Zheng, Tianyu; Finn, Caroline; Parrett, Christopher J; Dhume, Kunal; Hwang, Ji Hae; Sidhom, David; Strutt, Tara M; Li Sip, Yuen Yee; McKinstry, Karl K; Huo, Qun

    2017-11-10

    The ability to rapidly detect and diagnose acute viral infections is crucial for infectious disease control and management. Serology testing for the presence of virus-elicited antibodies in blood is one of the methods used commonly for clinical diagnosis of viral infections. However, standard serology-based tests have a significant limitation: they cannot easily distinguish active from past, historical infections. As a result, it is difficult to determine whether a patient is currently infected with a virus or not, and on an optimal course of action, based off of positive serology testing responses. Here, we report a nanoparticle-enabled blood test that can help overcome this major challenge. The new test is based on the analysis of virus-elicited immunoglobulin G (IgG) antibody present in the protein corona of a gold nanoparticle surface upon mixing the gold nanoparticles with blood sera. Studies conducted on mouse models of influenza A virus infection show that the test gives positive responses only in the presence of a recent acute viral infection, approximately between day 14 and day 21 following the infection, and becomes negative thereafter. When used together with the traditional serology testing, the nanoparticle test can determine clearly whether a positive serology response is due to a recent or historical viral infection. This new blood test can provide critical clinical information needed to optimize further treatment and/or to determine if further quarantining should be continued.

  7. The prostate health index PHI predicts oncological outcome and biochemical recurrence after radical prostatectomy - analysis in 437 patients.

    Science.gov (United States)

    Maxeiner, Andreas; Kilic, Ergin; Matalon, Julia; Friedersdorff, Frank; Miller, Kurt; Jung, Klaus; Stephan, Carsten; Busch, Jonas

    2017-10-03

    The purpose of this study was to investigate the Prostate-Health-Index (PHI) for pathological outcome prediction following radical prostatectomy and also for biochemical recurrence prediction in comparison to established parameters such as Gleason-score, pathological tumor stage, resection status (R0/1) and prostate-specific antigen (PSA). Out of a cohort of 460 cases with preoperative PHI-measurements (World Health Organization calibration: Beckman Coulter Access-2-Immunoassay) between 2001 and 2014, 437 patients with complete follow up data were included. From these 437 patients, 87 (19.9%) developed a biochemical recurrence. Patient characteristics were compared by using chi-square test. Predictors were analyzed by multivariate adjusted logistic and Cox regression. The median follow up for a biochemical recurrence was 65 (range 3-161) months. PHI, PSA, [-2]proPSA, PHI- and PSA-density performed as significant variables (p PHI, PSA, %fPSA, [-2]proPSA, PHI- and PSA-density significantly discriminated between stages PHI. In biochemical recurrence prediction PHI, PSA, [-2]proPSA, PHI- and PSA-density were the strongest predictors. In conclusion, due to heterogeneity of time spans to biochemical recurrence, longer follow up periods are crucial. This study with a median follow up of more than 5 years, confirmed a clinical value for PHI as an independent biomarker essential for biochemical recurrence prediction.

  8. Evaluation of pharmaceuticals removal by sewage sludge-derived adsorbents with rapid small-scale column tests

    Science.gov (United States)

    Zhang, P.; Ding, R.; Wallace, R.; Bandosz, T.

    2015-12-01

    New composite adsorbents were developed by pyrolyzing sewage sludge and fish waste (75:25 or 90:10 dry mass ratio) at 650 oC and 950 oC. Batch adsorption experiments demonstrated that the composite adsorbents were able to adsorb a wide range of organic contaminants (volatile organic compounds, pharmaceuticals and endocrine disrupting compounds (EDCs), and nitrosamine disinfection byproducts) with high capacities. Here we further examine the performance of the adsorbents for the simultaneous removal of 8 pharmaceuticals and EDCs with rapid small-scale column tests (RSSCT). Results show that the order of breakthrough in RSSCT is in general consistent with the affinity determined via batch tests. As expected, the maximum amount of adsorption for each compound obtained from RSSCT is identical to or less than that obtained from batch tests (with only one exception), due to adsorption kinetics. However, despite the very different input concentration (1 mg/L vs. 100 mg/L) and contact time (2 min empty bed contact time vs. 16 hour equilibrium time) used in RSSCT and batch tests, the maximum amount of pharmaceuticals and EDCs adsorbed under RSSCT is still about one half of that under equilibrium batch tests, validating the approach of using batch tests with much higher input concentrations to determine adsorption capacities. Results of a pilot-scale column test in a drinking water treatment plant for pharmaceuticals removal will also be presented.

  9. Will gay and bisexually active men at high risk of infection use over-the-counter rapid HIV tests to screen sexual partners?

    Science.gov (United States)

    Carballo-Diéguez, Alex; Frasca, Timothy; Dolezal, Curtis; Balan, Ivan

    2012-01-01

    The Food and Drug Administration may license OraQuick™, a rapid HIV test, for over-the-counter (OTC) sale. This study investigated whether HIV-uninfected, non-monogamous, gay and bisexual men who never or rarely use condoms would use the test with partners as a harm-reduction approach. Sixty participants responded to two computer-assisted self-interviews, underwent an in-depth interview, and chose whether to test themselves with OraQuick. Over 80% of the men said they would use the kit to test sexual partners or themselves if it became available OTC. Most participants understood that antibody tests have a window period in which the virus is undetectable, yet saw advantages to using the test to screen partners; 74% tested themselves in our offices. Participants offered several possible strategies to introduce the home-test idea to partners, frequently endorsed mutual testing, and highlighted that home testing could stimulate greater honesty in serostatus disclosure. Participants drew distinctions between testing regular versus occasional partners. Non-monogamous men who have sex with men, who never or rarely use condoms, may nevertheless seek to avoid HIV. Technologies that do not interfere with sexual pleasure are likely to be used when available. Studies are needed to evaluate the advantages and disadvantages of using OTC rapid HIV tests as one additional harm-reduction tool.

  10. A rapid phenol toxicity test based on photosynthesis and movement of the freshwater flagellate, Euglena agilis Carter

    Energy Technology Data Exchange (ETDEWEB)

    Kottuparambil, Sreejith [Institute of Green Environmental Research Center, Incheon National University, Incheon 406 840 (Korea, Republic of); Kim, Youn-Jung [Institute of Green Environmental Research Center, Incheon National University, Incheon 406 840 (Korea, Republic of); Department of Marine Science, Incheon National University, Incheon 406 840 (Korea, Republic of); Green-Pioneer (Ltd.), Incheon National University, Incheon 406 840 (Korea, Republic of); Choi, Hoon; Kim, Mi-Sung; Park, Areum; Park, Jihae [Institute of Green Environmental Research Center, Incheon National University, Incheon 406 840 (Korea, Republic of); Shin, Woongghi [Department of Biology, Chungnam University, Daejeon 306 764 (Korea, Republic of); Han, Taejun, E-mail: hanalgae@hanmail.net [Institute of Green Environmental Research Center, Incheon National University, Incheon 406 840 (Korea, Republic of); Department of Marine Science, Incheon National University, Incheon 406 840 (Korea, Republic of); Green-Pioneer (Ltd.), Incheon National University, Incheon 406 840 (Korea, Republic of)

    2014-10-15

    Highlights: • Rapid phenol toxicity tests (1 h) were developed based on Chl a fluorescence and the movement parameters of Euglena agilis. • Phenol significantly reduced F{sub v}/F{sub m} of PS II and rETRmax with EC50 values of 8.94 and 4.67 mM, respectively. • Among the movement parameters tested, velocity was the most sensitive biomarker with an EC50 of 3.17 mM. • The EC50 values for F{sub v}/F{sub m}, motility, and velocity appear to overlap the environmental permissible levels of phenol. - Abstract: Phenol, a monosubstituted aromatic hydrocarbon with various commercial uses, is a major organic constituent in industrial wastewaters. The ecotoxic action of phenol for aquatic environment is well known. In this study, rapid phenol toxicity tests (1 h) were developed based on chlorophyll a (Chl a) fluorescence and the movement parameters of the freshwater flagellate, Euglena agilis Carter. Phenol significantly reduced the maximum quantum yield (F{sub v}/F{sub m}) of photosystem II (PS II) and the maximum photosynthetic electron transport rate (rETR{sub max}) with median effective concentration (EC{sub 50}) values of 8.94 and 4.67 mM, respectively. Phenol reduced the motility and triggered change in the swimming velocity of the test organism. Among the parameters tested, velocity was the most sensitive biomarker with an EC{sub 50} of 3.17 mM. The EC{sub 50} values for F{sub v}/F{sub m}, motility, and velocity appear to overlap the permitted levels of phenol. In conclusion, the photosynthesis and movement of E. agilis can be fast and sensitive risk assessment parameters for the evaluation of phenol toxicity in municipal and industrial effluents.

  11. Qualification Testing Versus Quantitative Reliability Testing of PV - Gaining Confidence in a Rapidly Changing Technology: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Kurtz, Sarah [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Repins, Ingrid L [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Hacke, Peter L [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Jordan, Dirk [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Kempe, Michael D [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Whitfield, Kent [Underwriters Laboratories; Phillips, Nancy [DuPont; Sample, Tony [European Commission; Monokroussos, Christos [TUV Rheinland; Hsi, Edward [Swiss RE; Wohlgemuth, John [PowerMark Corporation; Seidel, Peter [First Solar; Jahn, Ulrike [TUV Rheinland; Tanahashi, Tadanori [National Institute of Advanced Industrial Science and Technology; Chen, Yingnan [China General Certification Center; Jaeckel, Bengt [Underwriters Laboratories; Yamamichi, Masaaki [RTS Corporation

    2017-10-05

    Continued growth of PV system deployment would be enhanced by quantitative, low-uncertainty predictions of the degradation and failure rates of PV modules and systems. The intended product lifetime (decades) far exceeds the product development cycle (months), limiting our ability to reduce the uncertainty of the predictions for this rapidly changing technology. Yet, business decisions (setting insurance rates, analyzing return on investment, etc.) require quantitative risk assessment. Moving toward more quantitative assessments requires consideration of many factors, including the intended application, consequence of a possible failure, variability in the manufacturing, installation, and operation, as well as uncertainty in the measured acceleration factors, which provide the basis for predictions based on accelerated tests. As the industry matures, it is useful to periodically assess the overall strategy for standards development and prioritization of research to provide a technical basis both for the standards and the analysis related to the application of those. To this end, this paper suggests a tiered approach to creating risk assessments. Recent and planned potential improvements in international standards are also summarized.

  12. Adolescents’ experience of a rapid HIV self-testing device in youth-friendly clinic settings in Cape Town South Africa: a cross-sectional community based usability study

    Science.gov (United States)

    Smith, Philip; Wallace, Melissa; Bekker, Linda-Gail

    2016-01-01

    Abstract Introduction: Since HIV testing in South African adolescents and young adults is sub-optimal, the objective of the current study was to investigate the feasibility and acceptability of an HIV rapid self-testing device in adolescents and young people at the Desmond Tutu HIV Foundation Youth Centre and Mobile Clinic. Methods: Self-presenting adolescents and young adults were invited to participate in a study investigating the fidelity, usability and acceptability of the AtomoRapid HIV Rapid self-testing device. Trained healthcare workers trained participants to use the device before the participant conducted the HIV self-test with device usage instructions. The healthcare worker then conducted a questionnaire-based survey to assess outcomes. Results: Of the 224 enrolled participants between 16 and 24 years of age, 155 (69,2%) were female. Overall, fidelity was high; 216 (96,4%) participants correctly completed the test and correctly read and interpreted the HIV test result. There were eight (3,6%) user errors overall; six participants failed to prick their finger even though the lancet fired correctly. There were two user errors where participants failed to use the capillary tube correctly. Participants rated acceptability and usability highly, with debut testers giving significantly higher ratings for both. Younger participants gave significantly higher ratings of acceptability. Conclusions: Adolescents and young adults found HIV self-testing highly acceptable with the AtomoRapid and they used the device accurately. Further research should investigate how, where and when to deploy HIV self-testing as a means to accompany existing strategies in reaching the UNAIDS goal to test 90% of all individuals worldwide. PMID:28406597

  13. Comparison of the Cerebrospinal Fluid (CSF) Toluidine Red Unheated Serum Test and the CSF Rapid Plasma Reagin Test with the CSF Venereal Disease Research Laboratory Test for Diagnosis of Neurosyphilis among HIV-Negative Syphilis Patients in China

    OpenAIRE

    Zhu, Lin; Gu, Xin; Peng, Rui-Rui; Wang, Cuini; Gao, Zixiao; Zhou, Pingyu; Gao, Ying; Shi, Mei; Guan, Zhifang; Seña, Arlene C.

    2014-01-01

    In this study, we aimed to investigate the performance of nontreponemal antibody tests in cerebrospinal fluid (CSF) specimens from syphilis patients. From September 2009 to September 2012, CSF specimens were collected at the Shanghai Skin Disease Hospital in Shanghai, China, from 1,132 syphilis patients without HIV infection, including 154 with symptomatic and 56 with asymptomatic neurosyphilis. All of the CSF specimens underwent testing with a rapid plasma reagin (RPR) test, an RPR-V (commer...

  14. Enhancing the Usability of an Optical Reader System to Support Point-of-Care Rapid Diagnostic Testing: An Iterative Design Approach.

    Science.gov (United States)

    Hohenstein, Jess; O'Dell, Dakota; Murnane, Elizabeth L; Lu, Zhengda; Erickson, David; Gay, Geri

    2017-11-21

    In today's health care environment, increasing costs and inadequate medical resources have created a worldwide need for more affordable diagnostic tools that are also portable, fast, and easy to use. To address this issue, numerous research and commercial efforts have focused on developing rapid diagnostic technologies; however, the efficacy of existing systems has been hindered by usability problems or high production costs, making them infeasible for deployment in at-home, point-of-care (POC), or resource-limited settings. The aim of this study was to create a low-cost optical reader system that integrates with any smart device and accepts any type of rapid diagnostic test strip to provide fast and accurate data collection, sample analysis, and diagnostic result reporting. An iterative design methodology was employed by a multidisciplinary research team to engineer three versions of a portable diagnostic testing device that were evaluated for usability and overall user receptivity. Repeated design critiques and usability studies identified a number of system requirements and considerations (eg, software compatibility, biomatter contamination, and physical footprint) that we worked to incrementally incorporate into successive system variants. Our final design phase culminated in the development of Tidbit, a reader that is compatible with any Wi-Fi-enabled device and test strip format. The Tidbit includes various features that support intuitive operation, including a straightforward test strip insertion point, external indicator lights, concealed electronic components, and an asymmetric shape, which inherently signals correct device orientation. Usability testing of the Tidbit indicates high usability for potential user communities. This study presents the design process, specification, and user reception of the Tidbit, an inexpensive, easy-to-use, portable optical reader for fast, accurate quantification of rapid diagnostic test results. Usability testing suggests

  15. What Is the Role of Paired Rapid Plasma Reagin Testing (Simultaneous Testing of Acute and Convalescent Samples) in the Diagnosis of Repeat Syphilis and the Follow-up of Syphilis?

    Science.gov (United States)

    Kenyon, Chris R; Osbak, Kara Krista; Van Esbroek, Marjan; Lynen, Lutgarde; Crucitti, Tania

    2018-01-01

    Repeat syphilis is playing an increasing role in syphilis transmission in several populations. The assessment of repeat syphilis and response to treatment depends on accurately measuring intraindividual changes in non-treponemal tests. For a 0- to 6-month delta rapid plasma reagin (RPR) to be determined by routine individual RPR testing, samples are tested 6 months apart with differences in reagent batches, environmental conditions, and observers all leading to measurement errors. We hypothesized that conducting paired RPR testing (simultaneous testing of acute and convalescent samples) would enable a more accurate determination of delta RPR compared with individual testing. A total of 120 study participants with a new diagnosis of syphilis were followed up at 0, 3, 6, 9, 12, 18, and 24 months, with RPR testing performed via individual testing at each study visit and at any suspected repeat syphilis. Rapid plasma reagin paired testing was performed on samples from 0 and 6 months and at any suspected repeat syphilis. The quantitative agreement ±1 dilution among paired and individual testing was 97.2%. There was no difference in the proportion with serofast status at 6 months: 21 (19.4%) and 19 (17.6%) according to paired and individual testing, respectively (P = 0.726). There was no statistically significant difference between 0- and 6-month delta RPR as determined by paired and individual testing in predicting seroresponse at 12 months (86.1% and 91.6% agreement with 12-month serofast/nonserofast classification, respectively; P = 0.262). In our setting, individual testing performed equally well compared with paired testing. Follow-up of syphilis will remain onerous for the patient and the health care provider until new tests that can more accurately assess the response to therapy and repeat syphilis/treatment failure are developed.

  16. Protective role of Tinospora cordifolia extract against radiation-induced qualitative, quantitative and biochemical alterations in testes

    International Nuclear Information System (INIS)

    Sharma, Priyanka; Parmar, Jyoti; Sharma, Priyanka; Verma, Preeti; Goyal, P.K.

    2012-01-01

    restoring almost normal structure at the end of experimentation. Furthermore, TCE administration inhibited radiation-induced elevation of lipid per-oxidation (LPO) and reduction of glutathione (GSH) and catalase (CAT) levels in testes. These observations signify that the Tinospora cordifolia root extract can be used as an efficient radio- protector against radiation mediated qualitative, quantitative and biochemical alterations in testes. (author)

  17. 40 CFR 158.2080 - Experimental use permit data requirements-biochemical pesticides.

    Science.gov (United States)

    2010-07-01

    ... requirements-biochemical pesticides. 158.2080 Section 158.2080 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PESTICIDE PROGRAMS DATA REQUIREMENTS FOR PESTICIDES Biochemical Pesticides § 158.2080 Experimental use permit data requirements—biochemical pesticides. (a) Sections 158.2081...

  18. Unique biochemical and mineral composition of whale ear bones.

    Science.gov (United States)

    Kim, Sora L; Thewissen, J G M; Churchill, Morgan M; Suydam, Robert S; Ketten, Darlene R; Clementz, Mark T

    2014-01-01

    Abstract Cetaceans are obligate aquatic mammals derived from terrestrial artiodactyls. The defining characteristic of cetaceans is a thick and dense lip (pachyosteosclerotic involucrum) of an ear bone (the tympanic). This unique feature is absent in modern terrestrial artiodactyls and is suggested to be important in underwater hearing. Here, we investigate the mineralogical and biochemical properties of the involucrum, as these may hold clues to the aquatic adaptations of cetaceans. We compared bioapatites (enamel, dentine, cementum, and skeletal bone) of cetaceans with those of terrestrial artiodactyls and pachyosteosclerotic ribs of manatees (Sirenia). We investigated organic, carbonate, and mineral composition as well as crystal size and crystallinity index. In all studied variables, bioapatites of the cetacean involucrum were intermediate in composition and structure between those of tooth enamel on the one hand and those of dentine, cementum, and skeletal bone on the other. We also studied the amino acid composition of the cetacean involucrum relative to that of other skeletal bone. The central involucrum had low glycine and hydroxyproline concentrations but high concentrations of nonessential amino acids, unlike most bone samples but similar to the tympanic of hippos and the (pachyosteosclerotic) ribs of manatees. These amino acid results are evidence of rapid bone development. We hypothesize that the mineralogical and amino acid composition of cetacean bullae differs from that of other bone because of (1) functional modifications for underwater sound reception and (2) structural adaptations related to rapid ossification.

  19. Laboratory evaluation of immunochromatographic rapid diagnostic tests for cholera in Haiti.

    Directory of Open Access Journals (Sweden)

    Wilfredo R Matias

    Full Text Available Rapid diagnostic tests (RDT for cholera are promising tools for detecting cholera in areas with limited laboratory infrastructure. However, evidence on the characteristics of the many available RDTs is scarce, and their use has been limited by suboptimal performance. We evaluated the performance characteristics of three cholera RDTs from Span Diagnostics, Artron Laboratories, and Standard Diagnostics in a regional laboratory in Haiti.We retrospectively reviewed records from May 2014 to October 2015 of a laboratory-based surveillance program for Vibrio cholerae at Hôpital Saint-Nicolas in Saint-Marc, Haiti. We compared the results of 511 Crystal VC, 129 Artron and 451 SD Bioline RDTs to bacterial culture as the gold standard. Of 905 cultures, 477 (52.7% were positive for V. cholerae O1, of which 27.7% were serotype Inaba. No cultures grew V. cholerae O139. Sensitivity and specificity of Crystal VC were 98.6% (95%CI: 96.5%-99.6% and 71.1% (95%CI: 64.7%-76.9%, respectively. Artron demonstrated a sensitivity of 98.6% (95%CI: 92.7%-100% and specificity of 69.1% (95%CI: 55.2%-80.9%. SD Bioline demonstrated a sensitivity of 81.1% (95%CI: 75.6%-85.8% and specificity of 92.8% (95%CI: 88.4%-95.9%. Crystal VC and Artron frequently showed false positive O139 bands, whereas none were seen with SD Bioline.There is significant variation in the performance of different cholera diagnostic RDTs. Artron and Crystal VC RDTs have high sensitivity and low specificity, while SD Bioline RDT has low to moderate sensitivity and high specificity when performed by laboratory technicians in Haiti. Study limitations included its retrospective design. The suboptimal characteristics of these tests limit their use as clinical point-of-care tests; however, they may be useful in outbreak response, surveillance, and research in resource-limited settings.

  20. Comparison of Rapid Diagnostic Tests and Microscopy for Malaria ...

    African Journals Online (AJOL)

    Presumptive treatment of malaria results in significant overuse of antimalarials. This study compared the diagnostic accuracy of Histidine Rich Protein II and plasmodium lactate dehydrogenase (pLDH)-based Rapid Kits( RDTs)and using expert microscopy as the gold standard for the detection of falciparum and ...

  1. The King-Devick (K-D) test of rapid eye movements: a bedside correlate of disability and quality of life in MS.

    Science.gov (United States)

    Moster, Stephen; Wilson, James A; Galetta, Steven L; Balcer, Laura J

    2014-08-15

    We investigated the King-Devick (K-D) test of rapid number naming as a visual performance measure in a cohort of patients with multiple sclerosis (MS). In this cross-sectional study, 81 patients with MS and 20 disease-free controls from an ongoing study of visual outcomes underwent K-D testing. A test of rapid number naming, K-D requires saccadic eye movements as well as intact vision, attention and concentration. To perform the K-D test, participants are asked to read numbers aloud as quickly as possible from three test cards; the sum of the three test card times in seconds constitutes the summary score. High-contrast visual acuity (VA), low-contrast letter acuity (1.25% and 2.5% levels), retinal nerve fiber layer (RNFL) thickness by optical coherence tomography (OCT), MS Functional Composite (MSFC) and vision-specific quality of life (QOL) measures (25-Item NEI Visual Functioning Questionnaire [NEI-VFQ-25] and 10-Item Neuro-Ophthalmic Supplement) were also assessed. K-D time scores in the MS cohort (total time to read the three test cards) were significantly higher (worse) compared to those for disease-free controls (P=0.003, linear regression, accounting for age). Within the MS cohort, higher K-D scores were associated with worse scores for the NEI-VFQ-25 composite (Paccounting for age and within-patient, inter-eye correlations). Patients with a history of optic neuritis (ON) had increased (worse) K-D scores. Patients who classified their work disability status as disabled (receiving disability pension) did worse on K-D testing compared to those working full-time (P=0.001, accounting for age). The K-D test, a work disability as well as structural changes as measured by OCT imaging. History of ON and abnormal binocular acuities were associated with worse K-D scores, suggesting that abnormalities detected by K-D may go along with afferent dysfunction in MS patients. A brief test that requires saccadic eye movements, K-D should be considered for future MS trials as

  2. Rapid urease test (RUT) for evaluation of urease activity in oral bacteria in vitro and in supragingival dental plaque ex vivo.

    Science.gov (United States)

    Dahlén, Gunnar; Hassan, Haidar; Blomqvist, Susanne; Carlén, Anette

    2018-05-18

    Urease is an enzyme produced by plaque bacteria hydrolysing urea from saliva and gingival exudate into ammonia in order to regulate the pH in the dental biofilm. The aim of this study was to assess the urease activity among oral bacterial species by using the rapid urease test (RUT) in a micro-plate format and to examine whether this test could be used for measuring the urease activity in site-specific supragingival dental plaque samples ex vivo. The RUT test is based on 2% urea in peptone broth solution and with phenol red at pH 6.0. Oral bacterial species were tested for their urease activity using 100 μl of RUT test solution in the well of a micro-plate to which a 1 μl amount of cells collected after growth on blood agar plates or in broth, were added. The color change was determined after 15, 30 min, and 1 and 2 h. The reaction was graded in a 4-graded scale (none, weak, medium, strong). Ex vivo evaluation of dental plaque urease activity was tested in supragingival 1 μl plaque samples collected from 4 interproximal sites of front teeth and molars in 18 adult volunteers. The color reaction was read after 1 h in room temperature and scored as in the in vitro test. The strongest activity was registered for Staphylococcus epidermidis, Helicobacter pylori, Campylobacter ureolyticus and some strains of Haemophilus parainfluenzae, while known ureolytic species such as Streptococcus salivarius and Actinomyces naeslundii showed a weaker, variable and strain-dependent activity. Temperature had minor influence on the RUT reaction. The interproximal supragingival dental plaque between the lower central incisors (site 31/41) showed significantly higher scores compared to between the upper central incisors (site 11/21), between the upper left first molar and second premolar (site 26/25) and between the lower right second premolar and molar (site 45/46). The rapid urease test (RUT) in a micro-plate format can be used as a simple and rapid method to test urease

  3. Acceptability of rapid HIV diagnosis technology among primary healthcare practitioners in Spain.

    Science.gov (United States)

    Agustí, C; Fernàndez-López, L; Mascort, J; Carrillo, R; Aguado, C; Montoliu, A; Puigdengolas, X; De La Poza, M; Rifà, B; Casabona, J

    2013-01-01

    This study investigated the acceptability of rapid HIV testing among general practitioners (GP) and aimed to identify perceived barriers and needs in order to implement rapid testing in primary care settings. An anonymous questionnaire was distributed online to all members of the two largest Spanish scientific medical societies for family and community medicine. The study took place between 15 June 2012 and 31 October 2010. Completed questionnaires were returned by 1308 participants. The majority (90.8%) of respondents were GP. Among all respondents, 70.4% were aware of the existence of rapid tests for the diagnosis of HIV but they did not know how to use them. Nearly 80% of participants would be willing to offer rapid HIV testing in their practices and 74.7% would be confident of the result obtained by these tests. The barriers most commonly identified by respondents were a lack of time and a need for training, both in the use of rapid tests (44.3% and 56.4%, respectively) and required pre- and post-test counselling (59.2% and 34.5%, respectively). This study reveals a high level of acceptance and willingness on the part of GPs to offer rapid HIV testing in their practices. Nevertheless, the implementation of rapid HIV testing in primary care will not be possible without moving from comprehensive pre-test counselling towards brief pre-test information and improving training in the use of rapid tests.

  4. Impact of introduction of rapid diagnostic tests for malaria on antibiotic prescribing: analysis of observational and randomised studies in public and private healthcare settings.

    Science.gov (United States)

    Hopkins, Heidi; Bruxvoort, Katia J; Cairns, Matthew E; Chandler, Clare I R; Leurent, Baptiste; Ansah, Evelyn K; Baiden, Frank; Baltzell, Kimberly A; Björkman, Anders; Burchett, Helen E D; Clarke, Siân E; DiLiberto, Deborah D; Elfving, Kristina; Goodman, Catherine; Hansen, Kristian S; Kachur, S Patrick; Lal, Sham; Lalloo, David G; Leslie, Toby; Magnussen, Pascal; Jefferies, Lindsay Mangham; Mårtensson, Andreas; Mayan, Ismail; Mbonye, Anthony K; Msellem, Mwinyi I; Onwujekwe, Obinna E; Owusu-Agyei, Seth; Reyburn, Hugh; Rowland, Mark W; Shakely, Delér; Vestergaard, Lasse S; Webster, Jayne; Wiseman, Virginia L; Yeung, Shunmay; Schellenberg, David; Staedke, Sarah G; Whitty, Christopher J M

    2017-03-29

    Objectives  To examine the impact of use of rapid diagnostic tests for malaria on prescribing of antimicrobials, specifically antibiotics, for acute febrile illness in Africa and Asia. Design  Analysisof nine preselected linked and codesigned observational and randomised studies (eight cluster or individually randomised trials and one observational study). Setting  Public and private healthcare settings, 2007-13, in Afghanistan, Cameroon, Ghana, Nigeria, Tanzania, and Uganda. Participants  522 480 children and adults with acute febrile illness. Interventions  Rapid diagnostic tests for malaria. Main outcome measures  Proportions of patients for whom an antibiotic was prescribed in trial groups who had undergone rapid diagnostic testing compared with controls and in patients with negative test results compared with patients with positive results. A secondary aim compared classes of antibiotics prescribed in different settings. Results  Antibiotics were prescribed to 127 052/238 797 (53%) patients in control groups and 167 714/283 683 (59%) patients in intervention groups. Antibiotics were prescribed to 40% (35 505/89 719) of patients with a positive test result for malaria and to 69% (39 400/57 080) of those with a negative result. All but one study showed a trend toward more antibiotic prescribing in groups who underwent rapid diagnostic tests. Random effects meta-analysis of the trials showed that the overall risk of antibiotic prescription was 21% higher (95% confidence interval 7% to 36%) in intervention settings. In most intervention settings, patients with negative test results received more antibiotic prescriptions than patients with positive results for all the most commonly used classes: penicillins, trimethoprim-sulfamethoxazole (one exception), tetracyclines, and metronidazole. Conclusions  Introduction of rapid diagnostic tests for malaria to reduce unnecessary use of antimalarials-a beneficial public health outcome-could drive

  5. [The value of different tests of the efficacy of iron supplementation].

    Science.gov (United States)

    Ladrière, Marc

    2006-11-01

    Iron status need to be acurately assessed to guid treatment which is necessary in management of anemia associated with chronic renal failure. Biochemical or cytologic tests can be used. As biochemical tests can be modified by inflammation or denutrition, specificity is sometimes quite low. Whereas it is not the case for cytologic ones, which need further discussions to choose the best cut-off value. Diagnosis of functional iron deficiency needs association of parameters. Poor disponiblity of cytologic tests make them difficult to use, but their usefullness become more and more recognized to complete study by biochemical ones which are known to fail to make correct evaluation in some cases.

  6. Screening for transfusion transmissible infections using rapid diagnostic tests in Africa: a potential hazard to blood safety?

    Science.gov (United States)

    Prugger, C.; Laperche, S.; Murphy, E. L.; Bloch, E. M.; Kaidarova, Z.; Tafflet, M.; Lefrère, J.-J.; Jouven, X.

    2016-01-01

    Rapid diagnostic tests (RDTs) are routinely used in African blood centres. We analysed data from two cross-sectional studies representing 95 blood centres in 29 African countries. Standardized panels of sera containing varying concentrations of anti-human immunodeficiency virus (HIV) antibodies (Ab), hepatitis B virus antigen (HBsAg) and antihepatitis C virus (HCV) Ab were screened using routine operational testing procedures at the centres. Sensitivity of detection using RDTs was high for HIV Ab-positive samples, but low for intermediately HBsAg (51·5%) and HCV Ab (40·6%)-positive samples. These findings suggest that current RDT use in Africa could pose a hazard to blood safety. PMID:26646317

  7. Usefulness of fibroblast culture for testing of cattle tissues polluted with heavy metals

    International Nuclear Information System (INIS)

    Weglarz, L.; Drozdz, M.Wa.; Wardas, M.; Kula, B.; Pawlaczyk-Szpilowa, M.

    1990-01-01

    Cattle tissues (liver, kidney, brain, and lung) that had been polluted with heavy metals were tested for their ability to alter fibroblast culture growth, cellular protein and DNA content, and fibroblast DNA synthesis. At 72 hr of incubation a significant increase in cellular DNA and [14C]thymidine incorporation was noted in the primary cultures as well as in the subcultures compared to controls. Fibroblast cultures also displayed growth inhibition and reduction in protein content. The measurement of basic biochemical parameters of the fibroblast culture may represent a sensitive means of assessing rapidly the activity of heavy metals deposited in the tissues of cattle as a result of their grazing on polluted soil

  8. Laboratory evaluation of three dual rapid diagnostic tests for HIV and syphilis in China and Nigeria.

    Science.gov (United States)

    Yin, Yue-Ping; Ngige, Evelyn; Anyaike, Chukwuma; Ijaodola, Gbenga; Oyelade, Taiwo A; Vaz, Rui Gama; Newman, Lori M; Chen, Xiang-Sheng

    2015-06-01

    To determine the laboratory-based performance and operational characteristics of three dual rapid diagnostic tests (RDTs) for testing HIV and syphilis. Three dual RDTs (SD Bioline, Chembio, and MedMira) were evaluated using 1514 serum specimens archived at laboratories or collected from clinics in China and Nigeria to determine sensitivity and specificity, with 95% confidence intervals. Concordance of testing results read by two technicians, stability of testing results read at two time points, and test operation characteristics were also assessed. All three of the evaluated RDTs gave excellent performance with a combined sensitivity ranging from 99.0%-99.6% for HIV and 98.3%-99.0% for syphilis, and a combined specificity ranging from 97.9%-99.0% for HIV and 97.2%-99.6% for syphilis. Concordance of testing results between two technicians and stability of testing results read within and one hour past the recommended reading period showed excellent agreement, with Kappa greater than or equal to 0.98. All the tests were found to be very or fairly easy to use and easy to interpret the results. Further evaluations of these dual RDTs with whole blood in field settings, and more studies on the implication of introduction of these tests in HIV and syphilis control programs are needed. Copyright © 2015. Published by Elsevier Ireland Ltd.

  9. Biochemical and biomechanical characterisation of equine cervical facet joint cartilage.

    Science.gov (United States)

    O'Leary, S A; White, J L; Hu, J C; Athanasiou, K A

    2018-04-15

    The equine cervical facet joint is a site of significant pathology. Located bilaterally on the dorsal spine, these diarthrodial joints work in conjunction with the intervertebral disc to facilitate appropriate spinal motion. Despite the high prevalence of pathology in this joint, the facet joint is understudied and thus lacking in viable treatment options. The goal of this study was to characterise equine facet joint cartilage and provide a comprehensive database describing the morphological, histological, biochemical and biomechanical properties of this tissue. Descriptive cadaver studies. A total of 132 facet joint surfaces were harvested from the cervical spines of six skeletally mature horses (11 surfaces per animal) for compiling biomechanical and biochemical properties of hyaline cartilage of the equine cervical facet joints. Gross morphometric measurements and histological staining were performed on facet joint cartilage. Creep indentation and uniaxial strain-to-failure testing were used to determine the biomechanical compressive and tensile properties. Biochemical assays included quantification of total collagen, sulfated glycosaminoglycan and DNA content. The facet joint surfaces were ovoid in shape with a flat articular surface. Histological analyses highlighted structures akin to articular cartilage of other synovial joints. In general, biomechanical and biochemical properties did not differ significantly between the inferior and superior joint surfaces as well as among spinal levels. Interestingly, compressive and tensile properties of cervical facet articular cartilage were lower than those of articular cartilage from other previously characterised equine joints. Removal of the superficial zone reduced the tissue's tensile strength, suggesting that this zone is important for the tensile integrity of the tissue. Facet surfaces were sampled at a single, central location and do not capture the potential topographic variation in cartilage properties. This

  10. Point-of-care genetic testing for personalisation of antiplatelet treatment (RAPID GENE): a prospective, randomised, proof-of-concept trial.

    Science.gov (United States)

    Roberts, Jason D; Wells, George A; Le May, Michel R; Labinaz, Marino; Glover, Chris; Froeschl, Michael; Dick, Alexander; Marquis, Jean-Francois; O'Brien, Edward; Goncalves, Sandro; Druce, Irena; Stewart, Alexandre; Gollob, Michael H; So, Derek Y F

    2012-05-05

    Prospective assessment of pharmacogenetic strategies has been limited by an inability to undertake bedside genetic testing. The CYP2C19*2 allele is a common genetic variant associated with increased rates of major adverse events in individuals given clopidogrel after percutaneous coronary intervention (PCI). We used a novel point-of-care genetic test to identify carriers of the CYP2C19*2 allele and aimed to assess a pharmacogenetic approach to dual antiplatelet treatment after PCI. Between Aug 26, 2010, and July 7, 2011, 200 patients were enrolled into our prospective, randomised, proof-of-concept study. Patients undergoing PCI for acute coronary syndrome or stable angina were randomly assigned to rapid point-of-care genotyping or to standard treatment. Individuals in the rapid genotyping group were screened for the CYP2C19*2 allele. Carriers were given 10 mg prasugrel daily, and non-carriers and patients in the standard treatment group were given 75 mg clopidogrel daily. The primary endpoint was the proportion of CYP2C19*2 carriers with high on-treatment platelet reactivity (P2Y12 reactivity unit [PRU] value of more than 234) after 1 week of dual antiplatelet treatment, which is a marker associated with increased adverse cardiovascular events. Interventional cardiologists and data analysts were masked to genetic status and treatment. Patients were not masked to treatment allocation. All analyses were by intention to treat. This study is registered with ClinicalTrials.gov, NCT01184300. After randomisation, 187 patients completed follow-up (91 rapid genotyping group, 96 standard treatment). 23 individuals in each group carried at least one CYP2C19*2 allele. None of the 23 carriers in the rapid genotyping group had a PRU value of more than 234 at day 7, compared with seven (30%) given standard treatment (p=0·0092). The point-of-care genetic test had a sensitivity of 100% (95% CI 92·3-100) and a specificity of 99·3% (96·3-100). Point-of-care genetic testing after

  11. Obtaining of a rapid diagnostic test for Cholera, based on latex particles coupled with a monoclonal antibody against Vibrio cholera O1 lipopolysaccharide

    Directory of Open Access Journals (Sweden)

    Fátima Reyes-López

    2015-08-01

    Full Text Available Cholera is an acute contagious intestinal disease caused by ingestion of food or water contaminated with O1 and O139 serotypes of the bacterium Vibrio cholerae. Cholera is characterized by abundant secretory diarrhea leading to dehydration. Death occurs within hours without treatment, so early diagnosis is very important, especially at the beginning of the disease, because it is difficult to differentiate from other acute diarrheal diseases. The diagnostic golden test is the stool culture; however, it does not guarantee a rapid detection of the disease. Rapid tests have been recently developed; they are based on test strips and agglutination with latex particles, which are very effective, but difficult to acquire for their high prices. The objective of this research was to obtain a quick assay based on latex particles coupled with a monoclonal antibody (mAb against V. cholerae O1 lipopolysaccharide obtained in Finlay Institute. Latex particles of 0.8 µm were used in a 10% suspension, and they were coupled to the mAb (0.25 mg/ml for 2 hours at 37°C. The sensitivity, specificity and performance were evaluated in 84 stool samples from patients with presumptive diagnosis of cholera. The diagnostic test obtained showed no cross-reactivity against no-O1 strains and other enteropathogens. Latex diagnostic test showed values of sensitivity, specificity and efficacy of 97.87; 97.29 and 97.6% respectively, very similar to the commercial diagnostic test CTK- Biotech. The latex reagent obtained can be used in the rapid diagnosis of the disease.

  12. Trematode infection modulates cockles biochemical response to climate change.

    Science.gov (United States)

    Magalhães, Luísa; de Montaudouin, Xavier; Figueira, Etelvina; Freitas, Rosa

    2018-05-06

    Resulting mainly from atmospheric carbon dioxide (CO 2 ) build-up, seawater temperature rise is among the most important climate change related factors affecting costal marine ecosystems. Global warming will have implications on the water cycle, increasing the risk of heavy rainfalls and consequent freshwater input into the oceans but also increasing the frequency of extreme drought periods with consequent salinity increase. For Europe, by the end of the century, projections describe an increase of CO 2 concentration up to 1120 ppm (corresponding to 0.5 pH unit decrease), an increase in the water temperature up to 4 °C and a higher frequency of heavy precipitation. These changes are likely to impact many biotic interactions, including host-parasite relationships which are particularly dependent on abiotic conditions. In the present study, we tested the hypothesis that the edible cockle, Cerastoderma edule, exposed to different salinity, temperature and pH levels as proxy for climate change, modify the infection success of the trematode parasite Himasthla elongata, with consequences to cockles biochemical performance. The results showed that the cercariae infection success increased with acidification but higher biochemical alterations were observed in infected cockles exposed to all abiotic experimental stressful conditions tested. The present study suggested that changes forecasted by many models may promote the proliferation of the parasites infective stages in many ecosystems leading to enhanced transmission, especially on temperate regions, that will influence the geographical distribution of some diseases and, probably, the survival capacity of infected bivalves. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. The Performance of a Rapid Diagnostic Test in Detecting Malaria Infection in Pregnant Women and the Impact of Missed Infections

    NARCIS (Netherlands)

    Williams, John E.; Cairns, Matthew; Njie, Fanta; Laryea Quaye, Stephen; Awine, Timothy; Oduro, Abraham; Tagbor, Harry; Bojang, Kalifa; Magnussen, Pascal; ter Kuile, Feiko O.; Woukeu, Arouna; Milligan, Paul; Chandramohan, Daniel; Greenwood, Brian

    2016-01-01

    Intermittent screening and treatment in pregnancy (ISTp) is a potential strategy for the control of malaria during pregnancy. However, the frequency and consequences of malaria infections missed by a rapid diagnostic test (RDT) for malaria are a concern. Primigravidae and secundigravidae who

  14. The Performance of a Rapid Diagnostic Test in Detecting Malaria Infection in Pregnant Women and the Impact of Missed Infections

    DEFF Research Database (Denmark)

    Williams, John E; Cairns, Matthew; Njie, Fanta

    2016-01-01

    BACKGROUND: Intermittent screening and treatment in pregnancy (ISTp) is a potential strategy for the control of malaria during pregnancy. However, the frequency and consequences of malaria infections missed by a rapid diagnostic test (RDT) for malaria are a concern.METHODS: Primigravidae and secu......BACKGROUND: Intermittent screening and treatment in pregnancy (ISTp) is a potential strategy for the control of malaria during pregnancy. However, the frequency and consequences of malaria infections missed by a rapid diagnostic test (RDT) for malaria are a concern.METHODS: Primigravidae...... in 540 women; these were not associated with maternal anemia, placental malaria, or low birth weight. CONCLUSIONS: The sensitivity of an RDT to detect malaria in primigravidae and secundigravidae was high at enrollment in 3 of 4 countries and, in Ghana, at subsequent ANC visits. In Ghana, RDT negative...... malaria infections were not associated with adverse birth outcomes but missed infections were uncommon....

  15. Bias due to Preanalytical Dilution of Rodent Serum for Biochemical Analysis on the Siemens Dimension Xpand Plus

    Directory of Open Access Journals (Sweden)

    Jennifer L. Johns

    2018-02-01

    Full Text Available Clinical pathology testing of rodents is often challenging due to insufficient sample volume. One solution in clinical veterinary and exploratory research environments is dilution of samples prior to analysis. However, published information on the impact of preanalytical sample dilution on rodent biochemical data is incomplete. The objective of this study was to evaluate the effects of preanalytical sample dilution on biochemical analysis of mouse and rat serum samples utilizing the Siemens Dimension Xpand Plus. Rats were obtained from end of study research projects. Mice were obtained from sentinel testing programs. For both, whole blood was collected via terminal cardiocentesis into empty tubes and serum was harvested. Biochemical parameters were measured on fresh and thawed frozen samples run straight and at dilution factors 2–10. Dilutions were performed manually, utilizing either ultrapure water or enzyme diluent per manufacturer recommendations. All diluted samples were generated directly from the undiluted sample. Preanalytical dilution caused clinically unacceptable bias in most analytes at dilution factors four and above. Dilution-induced bias in total calcium, creatinine, total bilirubin, and uric acid was considered unacceptable with any degree of dilution, based on the more conservative of two definitions of acceptability. Dilution often caused electrolyte values to fall below assay range precluding evaluation of bias. Dilution-induced bias occurred in most biochemical parameters to varying degrees and may render dilution unacceptable in the exploratory research and clinical veterinary environments. Additionally, differences between results obtained at different dilution factors may confound statistical comparisons in research settings. Comparison of data obtained at a single dilution factor is highly recommended.

  16. Developments in commercially produced microbials at Biochem Products

    Science.gov (United States)

    John Lublinkhof; Douglas H. Ross

    1985-01-01

    Biochem Products is part of a large industrial and scientific family - the Solvay Group. Solvay, headquartered in Brussels, Belgium is a multinational company with 46,000 employees worldwide. In the U.S., our working partners include a large polymer manufacturer, a peroxygen producer and a leading poultry and animal health products company. Biochem Products is a...

  17. Kombucha tea fermentation: Microbial and biochemical dynamics.

    Science.gov (United States)

    Chakravorty, Somnath; Bhattacharya, Semantee; Chatzinotas, Antonis; Chakraborty, Writachit; Bhattacharya, Debanjana; Gachhui, Ratan

    2016-03-02

    Kombucha tea, a non-alcoholic beverage, is acquiring significant interest due to its claimed beneficial properties. The microbial community of Kombucha tea consists of bacteria and yeast which thrive in two mutually non-exclusive compartments: the soup or the beverage and the biofilm floating on it. The microbial community and the biochemical properties of the beverage have so far mostly been described in separate studies. This, however, may prevent understanding the causal links between the microbial communities and the beneficial properties of Kombucha tea. Moreover, an extensive study into the microbial and biochemical dynamics has also been missing. In this study, we thus explored the structure and dynamics of the microbial community along with the biochemical properties of Kombucha tea at different time points up to 21 days of fermentation. We hypothesized that several biochemical properties will change during the course of fermentation along with the shifts in the yeast and bacterial communities. The yeast community of the biofilm did not show much variation over time and was dominated by Candida sp. (73.5-83%). The soup however, showed a significant shift in dominance from Candida sp. to Lachancea sp. on the 7th day of fermentation. This is the first report showing Candida as the most dominating yeast genus during Kombucha fermentation. Komagateibacter was identified as the single largest bacterial genus present in both the biofilm and the soup (~50%). The bacterial diversity was higher in the soup than in the biofilm with a peak on the seventh day of fermentation. The biochemical properties changed with the progression of the fermentation, i.e., beneficial properties of the beverage such as the radical scavenging ability increased significantly with a maximum increase at day 7. We further observed a significantly higher D-saccharic acid-1,4-lactone content and caffeine degradation property compared to previously described Kombucha tea fermentations. Our

  18. Testing iOS apps with HadoopUnit rapid distributed GUI testing

    CERN Document Server

    Tilley, Scott

    2014-01-01

    Smartphone users have come to expect high-quality apps. This has increased the importance of software testing in mobile software development. Unfortunately, testing apps-particularly the GUI-can be very time-consuming. Exercising every user interface element and verifying transitions between different views of the app under test quickly becomes problematic. For example, execution of iOS GUI test suites using Apple's UI Automation framework can take an hour or more if the app's interface is complicated. The longer it takes to run a test, the less frequently the test can be run, which in turn re

  19. HIV rapid testing in a Veterans Affairs hospital ED setting: a 5-year sustainability evaluation.

    Science.gov (United States)

    Knapp, Herschel; Hagedorn, Hildi; Anaya, Henry D

    2014-08-01

    Routine HIV testing in primary care settings is now recommended in the United States. The US Department of Veterans Affairs (VA) has increased the number of patients tested for HIV, but overall HIV testing rates in VA remain low. A proven strategy for increasing such testing involves nurse-initiated HIV rapid testing (HIV RT). The purpose of this work was to use a mixed methodology approach to evaluate the 5-year sustainability of an intervention that implemented HIV RT in a VA emergency department setting in a large, urban VA medical center to reduce missed diagnostic and treatment opportunities in this vulnerable patient population. In-person semistructured interviews were conducted with providers and stakeholders. Interview notes were qualitatively coded for emerging themes. Quarterly testing rates were evaluated for a 5-year time span starting from the launch in July 2008. Findings indicate that HIV RT was sustained by the enthusiasm of 2 clinical champions who oversaw the registered nurses responsible for conducting the testing. The departure of the clinical champions was correlated with a substantial drop-off in testing. Findings also indicate potential strategies for improving sustainability including engaging senior leadership in the project, engaging line staff in the implementation planning from the start to increase ownership over the innovation, incorporating information into initial training explaining the importance of the innovation to quality patient care, providing ongoing training to maintain skills, and providing routine progress reports to staff to demonstrate the ongoing impact of their efforts. Published by Elsevier Inc.

  20. Pathogenic bacteria and heavy metals toxicity assessments in evaluating unpasteurized raw milk quality through biochemical tests collected from dairy cows

    Directory of Open Access Journals (Sweden)

    Hamid Iqbal

    2016-11-01

    Full Text Available Objective: To evaluate the hygienic quality by determining the presence of predominant pathogenic microbial contaminants (contagious or environmental and indiscriminate heavy metals contained in unpasteurized milk samples collected from cattle specie of cow. Methods: Raw milk samples were collected in October, 2014 from different regions of District Kohat, Khyber Pakhtunkhwa, Pakistan and cultured on the selective media plates according to the manufacturer instructions to observe pathogenic microbial flora and confirm it with relevant biochemical tests to specify bacterial specie. Results: Milk samples analyzed on MacConkey and nutrient agar media were found contaminated mostly with coliform, Staphylococcus aureus, Enterobacter aerogenes and Proteus vulgaris. Similarly, result of the heavy metals analysis performed using atomic absorption spectrophotometer flame photometry showed that raw milk contains heavy metals residues of lead and cadmium contents at higher levels while copper, zinc and chromium were observed lower than permissible limits whereas manganese within specified recommended values. Conclusions: Microbial contamination of milk and toxic metals is mainly accredited to the scrupulous unhygienic measures during processing of milk exhibiting a wide array of hazardous impacts on human health.

  1. Performance of the Directigen EZ Flu A+B rapid influenza diagnostic test to detect pandemic influenza A/H1N1 2009.

    Science.gov (United States)

    Boyanton, Bobby L; Almradi, Amro; Mehta, Tejal; Robinson-Dunn, Barbara

    2014-04-01

    The Directigen EZ Flu A+B rapid influenza diagnostic test, as compared to real-time reverse transcriptase polymerase chain reaction, demonstrated suboptimal performance to detect pandemic influenza A/H1N1 2009. Age- and viral load-stratified test sensitivity ranged from 33.3 to 84.6% and 0 to 100%, respectively. © 2013.

  2. Use of rapid sampling microdialysis for intraoperative monitoring of bowel ischemia.

    Science.gov (United States)

    Deeba, S; Corcoles, E P; Hanna, G B; Hanna, B G; Pareskevas, P; Aziz, O; Boutelle, M G; Darzi, A

    2008-09-01

    Intestinal ischemia is a major cause of anastomotic leak and death and remains a clinical challenge as the physician relies on several nonspecific signs, biologic markers, and radiologic studies to make the diagnosis. This study used rapid sampling online microdialysis to evaluate the biochemical changes occurring in a segment of human bowel during and after resection, and assessed for the feasibility and reproducibility of this technique in monitoring intestinal ischemia. A custom made, rapid sampling online microdialysis analyzer was used to monitor the changes in the bowel wall of specimens being resected intraoperatively. Two patients were recruited for the pilot study to optimize the analyzer and seven patients undergoing colonic resections were recruited for the data collection and analysis. The concentration of glucose in the extracellular bowel wall fluid decreased transiently after division of individual feeding arteries followed by a rebound increase in the concentration back to baseline concentrations. After completion of resection, glucose concentrations continued to decrease while lactate concentrations increased constantly. Rapid sampling microdialysis was feasible in the clinical environment. These results suggest that tissue responds to ischemic insult by mobilizing glucose stores which later decrease again, whereas lactate concentrations constantly increased.

  3. Diagnostic accuracy and acceptability of rapid HIV oral testing among adults attending an urban public health facility in Kampala, Uganda.

    Directory of Open Access Journals (Sweden)

    Joanita Nangendo

    Full Text Available The prevalence of HIV in Uganda is 7.3%, and yet nearly 40% of people living with HIV are unaware of their status. The current HIV testing policy which is strictly blood-based poses several challenges including: a need for high level laboratory skills, stringent waste disposal needs, and painful sample collection. It is envisaged that introduction of a rapid, painless HIV oral fluid test as a potential alternative is likely to increase the number of people testing. The aim of this study was to determine the diagnostic accuracy and acceptability of rapid HIV oral testing among adults attending Kisenyi Health Centre IV in Kampala.We conducted a cross-sectional study among 440 adults recruited consecutively at Kisenyi Health Centre IV from January to March 2016. The diagnostic accuracy of the HIV oral test was assessed by comparing to the national HIV serial testing algorithm. We also assessed for acceptability among patients and health care workers (HCWs by triangulating responses from a structured questionnaire, three focus group discussions and seven key informant interviews. Acceptability was defined as willingness to take the test at the time of the study and intention for future use of the test if it was availed. The prevalence of HIV infection among study participants was 14.8%. The HIV oral fluid test was highly accurate with sensitivity of 100% (95% CI; 94.5-100.0, specificity of 100% (95% CI; 99.0-100.0, positive predictive value (PPV of 100% (95% CI; 94.5-100.0 and negative predictive value (NPV of 100% (95% CI; 99.0-100.0. Acceptability of HIV oral testing was also high at 87.0% (95% CI; 83.6-89.9. Participants preferred HIV oral testing because it was: pain free (91%, n = 399 and did not require blood draw (82%, n = 360.The HIV oral fluid test has high diagnostic accuracy and acceptability. HIV oral testing is a suitable addition to the national HIV testing strategies with the potential of increasing access to HIV testing services in

  4. Factor Analysis and Modelling for Rapid Quality Assessment of Croatian Wheat Cultivars with Different Gluten Characteristics

    Directory of Open Access Journals (Sweden)

    Želimir Kurtanjek

    2008-01-01

    Full Text Available Factor analysis and multivariate chemometric modelling for rapid assessment of baking quality of wheat cultivars from Slavonia region, Croatia, have been applied. The cultivars Žitarka, Kata, Monika, Ana, Demetra, Divana and Sana were grown under controlled conditions at the experimental field of Agricultural Institute Osijek during three years (2000–2002. Their quality properties were evaluated by 45 different chemical, physical and biochemical variables. The measured variables were grouped as: indirect quality parameters (6, farinographic parameters (7, extensographic parameters (5, baking test parameters (2 and reversed phase-high performance liquid chromatography (RP-HPLC of gluten proteins (25. The aim of this study is to establish minimal number (three, i.e. principal factors, among the 45 variables and to derive multivariate linear regression models for their use in simple and fast prediction of wheat properties. Selection of the principal factors based on the principal component analysis (PCA has been applied. The first three main factors of the analysis include: total glutenins (TGT, total ω-gliadins (Tω- and the ratio of dough resistance/extensibility (R/Ext. These factors account for 76.45 % of the total variance. Linear regression models gave average regression coefficients (R evaluated for the parameter groups: indirect quality R=0.91, baking test R=0.63, farinographic R=0.78, extensographic R=0.95 and RP-HPLC of gluten data R=0.90. Errors in the model predictions were evaluated by the 95 % significance intervals of the calibration lines. Practical applications of the models for rapid quality assessment and laboratory experiment planning were emphasized.

  5. JINR rapid communications

    International Nuclear Information System (INIS)

    1998-01-01

    The present collection of rapid communications from JINR, Dubna, contains seven separate records on invisible Z-boson width and restrictions on next-to-minimal supersymmetric standard model, cosmic test of honeycomb drift chambers, fission of 209 Bi, 232 Th, 235 U, 238 U and 237 Np in a spallation neutron field, rapid screening of spontaneous and radiation-induced structural changes at the vestigial gene of Drosophila melanogaster by polymerase chain reaction, gamma-ray multiplicities in sub-barrier fission of 226 Th and the decay constants of the scalar and pseudoscalar mesons in the quark models with quasilocal interaction

  6. Rapid and quantitative detection of the microbial spoilage of meat by fourier transform infrared spectroscopy and machine learning.

    Science.gov (United States)

    Ellis, David I; Broadhurst, David; Kell, Douglas B; Rowland, Jem J; Goodacre, Royston

    2002-06-01

    Fourier transform infrared (FT-IR) spectroscopy is a rapid, noninvasive technique with considerable potential for application in the food and related industries. We show here that this technique can be used directly on the surface of food to produce biochemically interpretable "fingerprints." Spoilage in meat is the result of decomposition and the formation of metabolites caused by the growth and enzymatic activity of microorganisms. FT-IR was exploited to measure biochemical changes within the meat substrate, enhancing and accelerating the detection of microbial spoilage. Chicken breasts were purchased from a national retailer, comminuted for 10 s, and left to spoil at room temperature for 24 h. Every hour, FT-IR measurements were taken directly from the meat surface using attenuated total reflectance, and the total viable counts were obtained by classical plating methods. Quantitative interpretation of FT-IR spectra was possible using partial least-squares regression and allowed accurate estimates of bacterial loads to be calculated directly from the meat surface in 60 s. Genetic programming was used to derive rules showing that at levels of 10(7) bacteria.g(-1) the main biochemical indicator of spoilage was the onset of proteolysis. Thus, using FT-IR we were able to acquire a metabolic snapshot and quantify, noninvasively, the microbial loads of food samples accurately and rapidly in 60 s, directly from the sample surface. We believe this approach will aid in the Hazard Analysis Critical Control Point process for the assessment of the microbiological safety of food at the production, processing, manufacturing, packaging, and storage levels.

  7. Screening test for rapid food safety evaluation by menadione-catalysed chemiluminescent assay.

    Science.gov (United States)

    Yamashoji, Shiro; Yoshikawa, Naoko; Kirihara, Masayuki; Tsuneyoshi, Toshihiro

    2013-06-15

    The chemiluminescent assay of menadione-catalysed H2O2 production by living mammalian cells was proposed to be useful for rapid food safety evaluation. The tested foods were extracted with water, ethanol and dimethylsulfoxide, and each extract was incubated with NIH3T3, Neuro-2a and HepG2 cells for 4h. Menadione-catalysed H2O2 production by living mammalian cells exposed to each extract was determined by the chemiluminescent assay requiring only 10 min, and the viability of the cells was estimated as percentage based on H2O2 production by intact cells. In this study the cytotoxicity of food was rated in order of inhibitory effect on H2O2 production by intact cells. The well known natural toxins such as Fusarium mycotoxin, tomato toxin tomatine, potato toxin solanine and marine toxins terodotoxin and brevetoxin could be detected by the above chemiluminescent assay. Copyright © 2012 Elsevier Ltd. All rights reserved.

  8. Measures of Biochemical Sociology

    Science.gov (United States)

    Snell, Joel; Marsh, Mitchell

    2008-01-01

    In a previous article, the authors introduced a new sub field in sociology that we labeled "biochemical sociology." We introduced the definition of a sociology that encompasses sociological measures, psychological measures, and biological indicators Snell & Marsh (2003). In this article, we want to demonstrate a research strategy that would assess…

  9. Rapid and quantitative detection of C-reactive protein using quantum dots and immunochromatographic test strips

    Directory of Open Access Journals (Sweden)

    Cheng X

    2014-12-01

    Full Text Available Xianglin Cheng,1,* Xu Pu,2,* Pen Jun,3 XiaoBo Zhu,3 Di Zhu,4 Ming Chen1 1Department of Laboratory Medicine, First Affiliated Hospital of Yangtze University, Jingzhou, 2Department of Laboratory Medicine, RenMin Hospital of Wuhan University, Wuhan, 3Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education, College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, Hubei, People’s Republic of China; 4Department of Medical Oncology, Dana-Farber Cancer Institute, Harvard Medical School, Boston, MA, USA *These authors contributed equally to this study and share first authorship Background: Rapid immunochromatographic tests can detect disease markers in 10–15 minutes, which facilitates clinical diagnosis and treatment programs. However, most immunochromatographic tests employ gold nanoparticles as reporters, and these have only moderate sensitivity and act as qualitative methods for analyzing high biomarker concentrations. Methods: In this study, we introduce quantum dots (QDs as fluorescent probes and immunochromatographic strips to develop quantitative fluorescence point-of-care tests (QF-POCT to analyze C-reactive protein (CRP levels. Goat anti-rabbit IgG and rabbit IgG were used as control antibodies, and mouse monoclonal CRP antibody pairs were used for disease marker detection. One monoclonal CRP antibody was conjugated with QDs and served as a signal antibody, and the other monoclonal CRP antibody was dispensed onto the nitrocellulose membrane and served as a capturing antibody. In the presence of CRP, the fluorescence intensity of the monoclonal antibody-CRP-monoclonal antibody sandwich complex captured on the nitrocellulose membrane was determined using the fluorescence strip reader. Results: QF-POCT assays could quantitatively analyze the concentration of CRP in 15 minutes had a detection limit of 0.25 mg/L, and had a wide detection linearity range (0.5–300 mg/L. The intra-assay and interassay

  10. Commercial herbal medicines used as African traditional medicines: Ngoma Herbal Tonic Immune Booster interferes with a rapid urine drug screening test.

    Science.gov (United States)

    Mothibe, M E; Osuch, E; Kahler-Venter, C P

    2017-08-25

    The prevalent use of African traditional medicine by the general public has been reported. With commercialisation and marketing, some of the herbal medicines (HMs) used are readily available over the counter, most of them promoted as immune boosters. These commercial HMs have not been taken through clinical trials and other tests that would validate their composition and safety, and other properties such as their effect on laboratory diagnostic tests. To investigate the cross-reactivity of selected HMs with commonly tested drugs of abuse (DoA) using a qualitative rapid urinalysis assay. The six HMs selected were bought from local pharmacies. A rapid urinalysis screening test was performed with the Instant View Multi-Drug of Abuse Test kit from Labstix Diagnostics. Drug-free urine (DFU) was pooled from samples donated by healthy volunteers. Urine samples that had tested positive for DoA were obtained from a pharmacology laboratory. Aliquots of the urine samples were spiked with the HMs in neat and diluted form, and tested at various time intervals. The results for the DFU samples spiked with the HMs remained negative. There were no significant changes in pH or specific gravity of the samples. The results of samples that had tested positive for tetrahydrocannabinol (THC) were not altered by five of the HMs when spiked at 40% v/v. The HM Ngoma Herbal Tonic Immune Booster caused false-negative results for the THC test. An important finding is that the herbal mixture Ngoma Herbal Tonic Immune Booster caused false-negative results for the cannabinoid screening test. It adds to the list of substances that may be potential adulterants of urine for screening tests.

  11. Discovering Reliable Sources of Biochemical Thermodynamic Data to Aid Students' Understanding

    Science.gov (United States)

    Me´ndez, Eduardo; Cerda´, María F.

    2016-01-01

    Students of physical chemistry in biochemical disciplines need biochemical examples to capture the need, not always understood, of a difficult area in their studies. The use of thermodynamic data in the chemical reference state may lead to incorrect interpretations in the analysis of biochemical examples when the analysis does not include relevant…

  12. Computer Simulation in Predicting Biochemical Processes and Energy Balance at WWTPs

    Science.gov (United States)

    Drewnowski, Jakub; Zaborowska, Ewa; Hernandez De Vega, Carmen

    2018-02-01

    Nowadays, the use of mathematical models and computer simulation allow analysis of many different technological solutions as well as testing various scenarios in a short time and at low financial budget in order to simulate the scenario under typical conditions for the real system and help to find the best solution in design or operation process. The aim of the study was to evaluate different concepts of biochemical processes and energy balance modelling using a simulation platform GPS-x and a comprehensive model Mantis2. The paper presents the example of calibration and validation processes in the biological reactor as well as scenarios showing an influence of operational parameters on the WWTP energy balance. The results of batch tests and full-scale campaign obtained in the former work were used to predict biochemical and operational parameters in a newly developed plant model. The model was extended with sludge treatment devices, including anaerobic digester. Primary sludge removal efficiency was found as a significant factor determining biogas production and further renewable energy production in cogeneration. Water and wastewater utilities, which run and control WWTP, are interested in optimizing the process in order to save environment, their budget and decrease the pollutant emissions to water and air. In this context, computer simulation can be the easiest and very useful tool to improve the efficiency without interfering in the actual process performance.

  13. Computer Simulation in Predicting Biochemical Processes and Energy Balance at WWTPs

    Directory of Open Access Journals (Sweden)

    Drewnowski Jakub

    2018-01-01

    Full Text Available Nowadays, the use of mathematical models and computer simulation allow analysis of many different technological solutions as well as testing various scenarios in a short time and at low financial budget in order to simulate the scenario under typical conditions for the real system and help to find the best solution in design or operation process. The aim of the study was to evaluate different concepts of biochemical processes and energy balance modelling using a simulation platform GPS-x and a comprehensive model Mantis2. The paper presents the example of calibration and validation processes in the biological reactor as well as scenarios showing an influence of operational parameters on the WWTP energy balance. The results of batch tests and full-scale campaign obtained in the former work were used to predict biochemical and operational parameters in a newly developed plant model. The model was extended with sludge treatment devices, including anaerobic digester. Primary sludge removal efficiency was found as a significant factor determining biogas production and further renewable energy production in cogeneration. Water and wastewater utilities, which run and control WWTP, are interested in optimizing the process in order to save environment, their budget and decrease the pollutant emissions to water and air. In this context, computer simulation can be the easiest and very useful tool to improve the efficiency without interfering in the actual process performance.

  14. Biochemically verified smoking cessation and vaping beliefs among vape store customers.

    Science.gov (United States)

    Tackett, Alayna P; Lechner, William V; Meier, Ellen; Grant, DeMond M; Driskill, Leslie M; Tahirkheli, Noor N; Wagener, Theodore L

    2015-05-01

    To evaluate biochemically verified smoking status and electronic nicotine delivery systems (ENDS) use behaviors and beliefs among a sample of customers from vapor stores (stores specializing in ENDS). A cross-sectional survey of 215 adult vapor store customers at four retail locations in the Midwestern United States; a subset of participants (n = 181) also completed exhaled carbon monoxide (CO) testing to verify smoking status. Outcomes evaluated included ENDS preferences, harm beliefs, use behaviors, smoking history and current biochemically verified smoking status. Most customers reported starting ENDS as a means of smoking cessation (86%), using newer-generation devices (89%), vaping non-tobacco/non-menthol flavors (72%) and using e-liquid with nicotine strengths of ≤20 mg/ml (72%). There was a high rate of switching (91.4%) to newer-generation ENDS among those who started with a first-generation product. Exhaled CO readings confirmed that 66% of the tested sample had quit smoking. Among those who continued to smoke, mean cigarettes per day decreased from 22.1 to 7.5 (P customers in the United States who use electronic nicotine delivery devices to stop smoking, vaping longer, using newer-generation devices and using non-tobacco and non-menthol flavored e-liquid appear to be associated with higher rates of smoking cessation. © 2015 Society for the Study of Addiction.

  15. 'BioNessie(G) - a grid enabled biochemical networks simulation environment

    OpenAIRE

    Liu, X; Jiang, J; Ajayi, O; Gu, X; Gilbert, D; Sinnott, R

    2008-01-01

    The simulation of biochemical networks provides insight and understanding about the underlying biochemical processes and pathways used by cells and organisms. BioNessie is a biochemical network simulator which has been developed at the University of Glasgow. This paper describes the simulator and focuses in particular on how it has been extended to benefit from a wide variety of high performance compute resources across the UK through Grid technologies to support larger scal...

  16. Accuracy of individual rapid tests for serodiagnosis of gambiense sleeping sickness in West Africa.

    Directory of Open Access Journals (Sweden)

    Vincent Jamonneau

    2015-02-01

    Full Text Available Individual rapid tests for serodiagnosis (RDT of human African trypanosomiasis (HAT are particularly suited for passive screening and surveillance. However, so far, no large scale evaluation of RDTs has been performed for diagnosis of Trypanosoma brucei gambiense HAT in West Africa. The objective of this study was to assess the diagnostic accuracy of 2 commercial HAT-RDTs on stored plasma samples from West Africa.SD Bioline HAT and HAT Sero-K-Set were performed on 722 plasma samples originating from Guinea and Côte d'Ivoire, including 231 parasitologically confirmed HAT patients, 257 healthy controls, and 234 unconfirmed individuals whose blood tested antibody positive in the card agglutination test but negative by parasitological tests. Immune trypanolysis was performed as a reference test for trypanosome specific antibody presence. Sensitivities in HAT patients were respectively 99.6% for SD Bioline HAT, and 99.1% for HAT Sero-K-Set, specificities in healthy controls were respectively 87.9% and 88.3%. Considering combined positivity in both RDTs, increased the specificity significantly (p ≤ 0.0003 to 93.4%, while 98.7% sensitivity was maintained. Specificities in controls were 98.7-99.6% for the combination of one or two RDTs with trypanolysis, maintaining a sensitivity of at least 98.1%.The observed specificity of the single RDTs was relatively low. Serial application of SD Bioline HAT and HAT Sero-K-Set might offer superior specificity compared to a single RDT, maintaining high sensitivity. The combination of one or two RDTs with trypanolysis seems promising for HAT surveillance.

  17. Exploring basic biochemical constituents in the body tissues of ...

    African Journals Online (AJOL)

    Feeding regime did not influence susceptibility to mass loss during export. Animal age influenced the biochemical composition and export performance of abalone. Keywords: abalone; aquaculture; feeds; Haliotis midae; live export; mass loss; tissue biochemical constituents. African Journal of Marine Science 2010, 32(1): ...

  18. Biochemical indicators for novel forest decline in spruce

    International Nuclear Information System (INIS)

    Baur, M.; Lauchert, U.; Wild, A.

    1998-01-01

    The impact of air pollution on 24 stands of spruce trees in several regions in Germany was investigated. We looked for evidence of biochemical and physiological change at the level of the photosynthetic thylakoid membranes as well as for changes in the antioxidative system in two year old needles. We observed that, as the chlorophyll content decreases in the needles, the among of D1 protein declines far more rapidly in relation to the redox components P700 and cytochrome f. Consequently, the PSII/PSI stoichiometry keeps dropping to progressively lower, meaning unfavorable, values at the chlorophyll content diminishes. This is particularly the case in the higher elevation characteristically increases while the D1 protein content falls. The higher α-tocopherol values, however, are obviously neither able to protect the D1 protein from degradation nor to compensate for the higher oxidative stress. Apart from that the ascorbate/tocopherol ratios remained in the majority of cases in the unfavorable range of far below 10, where an effective protection of the membranes from free radicals is not guaranteed. This then is mirrored in the increased degradation of D1 and the lower PSII/PSI ratio

  19. Viral hepatitis and rapid diagnostic test based screening for HBsAg in HIV-infected patients in rural Tanzania.

    Directory of Open Access Journals (Sweden)

    Fabian C Franzeck

    Full Text Available BACKGROUND: Co-infection with hepatitis B virus (HBV is highly prevalent in people living with HIV in Sub-Saharan Africa. Screening for HBV surface antigen (HBsAg before initiation of combination antiretroviral therapy (cART is recommended. However, it is not part of diagnostic routines in HIV programs in many resource-limited countries although patients could benefit from optimized antiretroviral therapy covering both infections. Screening could be facilitated by rapid diagnostic tests for HBsAg. Operating experience with these point of care devices in HIV-positive patients in Sub-Saharan Africa is largely lacking. We determined the prevalence of HBV and Hepatitis C virus (HCV infection as well as the diagnostic accuracy of the rapid test device Determine HBsAg in an HIV cohort in rural Tanzania. METHODS: Prospectively collected blood samples from adult, HIV-1 positive and antiretroviral treatment-naïve patients in the Kilombero and Ulanga antiretroviral cohort (KIULARCO in rural Tanzania were analyzed at the point of care with Determine HBsAg, a reference HBsAg EIA and an anti-HCV EIA. RESULTS: Samples of 272 patients were included. Median age was 38 years (interquartile range [IQR] 32-47, 169/272 (63% subjects were females and median CD4+ count was 250 cells/µL (IQR 97-439. HBsAg was detected in 25/272 (9.2%, 95% confidence interval [CI] 6.2-13.0% subjects. Of these, 7/25 (28% were positive for HBeAg. Sensitivity of Determine HBsAg was rated at 96% (95% CI 82.8-99.6% and specificity at 100% (95% CI, 98.9-100%. Antibodies to HCV (anti-HCV were found in 10/272 (3.7%, 95% CI 2.0-6.4% of patients. CONCLUSION: This study reports a high prevalence of HBV in HIV-positive patients in a rural Tanzanian setting. The rapid diagnostic test Determine HBsAg is an accurate assay for screening for HBsAg in HIV-1 infected patients at the point of care and may further help to guide cART in Sub-Saharan Africa.

  20. Addressing Barriers to the Development and Adoption of Rapid Diagnostic Tests in Global Health

    Directory of Open Access Journals (Sweden)

    Eric Miller

    2015-06-01

    Full Text Available Immunochromatographic rapid diagnostic tests (RDTs have demonstrated significant potential for use as point-of- care diagnostic tests in resource-limited settings. Most notably, RDTs for malaria have reached an unparalleled level of technological maturity and market penetration, and are now considered an important complement to standard microscopic methods of malaria diagnosis. However, the technical development of RDTs for other infectious diseases, and their uptake within the global health community as a core diagnostic modality, has been hindered by a number of extant challenges. These range from technical and biological issues, such as the need for better affinity agents and biomarkers of disease, to social, infrastructural, regulatory and economic barriers, which have all served to slow their adoption and diminish their impact. In order for the immunochromatographic RDT format to be successfully adapted to other disease targets, to see widespread distribution, and to improve clinical outcomes for patients on a global scale, these challenges must be identified and addressed, and the global health community must be engaged in championing the broader use of RDTs.

  1. Addressing Barriers to the Development and Adoption of Rapid Diagnostic Tests in Global Health

    Directory of Open Access Journals (Sweden)

    Eric Miller

    2015-06-01

    Full Text Available Immunochromatographic rapid diagnostic tests (RDTs have demonstrated significant potential for use as point-of-care diagnostic tests in resource-limited settings. Most notably, RDTs for malaria have reached an unparalleled level of technological maturity and market penetration, and are now considered an important complement to standard microscopic methods of malaria diagnosis. However, the technical development of RDTs for other infectious diseases, and their uptake within the global health community as a core diagnostic modality, has been hindered by a number of extant challenges. These range from technical and biological issues, such as the need for better affinity agents and biomarkers of disease, to social, infrastructural, regulatory and economic barriers, which have all served to slow their adoption and diminish their impact. In order for the immunochromatographic RDT format to be successfully adapted to other disease targets, to see widespread distribution, and to improve clinical outcomes for patients on a global scale, these challenges must be identified and addressed, and the global health community must be engaged in championing the broader use of RDTs.

  2. Addressing Barriers to the Development and Adoption of Rapid Diagnostic Tests in Global Health.

    Science.gov (United States)

    Miller, Eric; Sikes, Hadley D

    Immunochromatographic rapid diagnostic tests (RDTs) have demonstrated significant potential for use as point-of-care diagnostic tests in resource-limited settings. Most notably, RDTs for malaria have reached an unparalleled level of technological maturity and market penetration, and are now considered an important complement to standard microscopic methods of malaria diagnosis. However, the technical development of RDTs for other infectious diseases, and their uptake within the global health community as a core diagnostic modality, has been hindered by a number of extant challenges. These range from technical and biological issues, such as the need for better affinity agents and biomarkers of disease, to social, infrastructural, regulatory and economic barriers, which have all served to slow their adoption and diminish their impact. In order for the immunochromatographic RDT format to be successfully adapted to other disease targets, to see widespread distribution, and to improve clinical outcomes for patients on a global scale, these challenges must be identified and addressed, and the global health community must be engaged in championing the broader use of RDTs.

  3. Magnetic Fe3O4@TiO2 Nanoparticles-based Test Strip Immunosensing Device for Rapid Detection of Phosphorylated Butyrylcholinesterase

    Energy Technology Data Exchange (ETDEWEB)

    Ge, Xiaoxiao; Zhang, Weiying; Lin, Yuehe; Du, Dan

    2013-12-15

    An integrated magnetic nanoparticles-based test-strip immunosensing device was developed for rapid and sensitive quantification of phosphorylated butyrylcholinesterase (BChE), the biomarker of exposure to organophosphous pesticides (OP), in human plasma. In order to overcome the difficulty in scarce availability of OP-specific antibody, here magnetic Fe3O4@TiO2 nanoparticles were used and adsorbed on the test strip through a small magnet inserted in the device to capture target OP-BChE through selective binding between TiO2 and OP moiety. Further recognition was completed by horseradish peroxidase (HRP) and anti-BChE antibody (Ab) co-immobilized gold nanoparticles (GNPs). Their strong affinities among Fe3O4@TiO2, OP-BChE and HRP/Ab-GNPs were characterized by quartz crystal microbalance (QCM), surface plasmon resonance (SPR) and square wave voltammetry (SWV) measurements. After cutting off from test strip, the resulted immunocomplex (HRP/Ab-GNPs/OP-BChE/Fe3O4@TiO2) was measured by SWV using a screen printed electrode under the test zone. Greatly enhanced sensitivity was achieved by introduction of GNPs to link enzyme and antibody at high ratio, which amplifies electrocatalytic signal significantly. Moreover, the use of test strip for fast immunoreactions reduces analytical time remarkably. Coupling with a portable electrochemical detector, the integrated device with advanced nanotechnology displays great promise for sensitive, rapid and in-filed on-site evaluation of OP poisoning.

  4. Hepatobiliary magnetic resonance imaging in patients with liver disease: correlation of liver enhancement with biochemical liver function tests

    Energy Technology Data Exchange (ETDEWEB)

    Kukuk, Guido M.; Schaefer, Stephanie G.; Hadizadeh, Dariusch R.; Schild, Hans H.; Willinek, Winfried A. [University of Bonn, Department of Radiology, Bonn (Germany); Fimmers, Rolf [University of Bonn, Department of Medical Biometry, Informatics and Epidemiology, Bonn (Germany); Ezziddin, Samer [Department of Nuclear Medicine, Bonn (Germany); Spengler, Ulrich [Department of Internal Medicine I, Bonn (Germany)

    2014-10-15

    To evaluate hepatobiliary magnetic resonance imaging (MRI) using Gd-EOB-DTPA in relation to various liver function tests in patients with liver disorders. Fifty-one patients with liver disease underwent Gd-EOB-DTPA-enhanced liver MRI. Based on region-of-interest (ROI) analysis, liver signal intensity was calculated using the spleen as reference tissue. Liver-spleen contrast ratio (LSCR) and relative liver enhancement (RLE) were calculated. Serum levels of total bilirubin, gamma glutamyl transpeptidase (GGT), aspartate aminotransferase (AST), alanine aminotransferase (ALT), glutamate dehydrogenase (GLDH), lactate dehydrogenase (LDH), serum albumin level (AL), prothrombin time (PT), creatinine (CR) as well as international normalised ratio (INR) and model for end-stage liver disease (MELD) score were tested for correlation with LSCR and RLE. Pre-contrast LSCR values correlated with total bilirubin (r = -0.39; p = 0.005), GGT (r = -0.37; p = 0.009), AST (r = -0.38; p = 0.013), ALT (r = -0.29; p = 0.046), PT (r = 0.52; p < 0.001), GLDH (r = -0.55; p = 0.044), INR (r = -0.42; p = 0.003), and MELD Score (r = -0.53; p < 0.001). After administration of Gd-EOB-DTPA bilirubin (r = -0.45; p = 0.001), GGT (r = -0.40; p = 0.004), PT (r = 0.54; p < 0.001), AST (r = -0.46; p = 0.002), ALT (r = -0.31; p = 0.030), INR (r = -0.45; p = 0.001) and MELD Score (r = -0.56; p < 0.001) significantly correlated with LSCR. RLE correlated with bilirubin (r = -0.40; p = 0.004), AST (r = -0.38; p = 0.013), PT (r = 0.42; p = 0.003), GGT (r = -0.33; p = 0.020), INR (r = -0.36; p = 0.011) and MELD Score (r = -0.43; p = 0.003). Liver-spleen contrast ratio and relative liver enhancement using Gd-EOB-DTPA correlate with a number of routinely used biochemical liver function tests, suggesting that hepatobiliary MRI may serve as a valuable biomarker for liver function. The strongest correlation with liver enhancement was found for the MELD Score. (orig.)

  5. A retrospective evaluation of proficiency testing, and rapid HIV test ...

    African Journals Online (AJOL)

    Background: Proficiency testing (PT) has been implemented as a form of External Quality Assurance (EQA) by the National HIV Reference Laboratory in Kenya since 2007 in order to monitor and improve on the quality of HIV testing and counselling HTC services. Objective: To compare concordance between National HIV ...

  6. 3’-Deoxyadenosine (Cordycepin) Produces a Rapid and Robust Antidepressant Effect via Enhancing Prefrontal AMPA Receptor Signaling Pathway

    Science.gov (United States)

    Li, Bai; Hou, Yangyang; Zhu, Ming; Bao, Hongkun; Nie, Jun; Zhang, Grace Y.; Shan, Liping; Yao, Yao; Du, Kai; Yang, Hongju; Li, Meizhang; Zheng, Bingrong; Xu, Xiufeng; Xiao, Chunjie; Du, Jing

    2016-01-01

    Background: The development of rapid and safe antidepressants for the treatment of major depression is in urgent demand. Converging evidence suggests that glutamatergic signaling seems to play important roles in the pathophysiology of depression. Methods: We studied the antidepressant effects of 3’-deoxyadenosine (3’-dA, Cordycepin) and the critical role of the α-amino-3-hydroxy-5-methyl-4-isoxazole propionic acid (AMPA) receptor in male CD-1 mice via behavioral and biochemical experiments. After 3’-dA treatment, the phosphorylation and synaptic localization of the AMPA receptors GluR1 and GluR2 were determined in the prefrontal cortex (PFC) and hippocampus (HIP). The traditional antidepressant imipramine was applied as a positive control. Results: We found that an injection of 3’-dA led to a rapid and robust antidepressant effect, which was significantly faster and stronger than imipramine, after 45min in tail suspension and forced swim tests. This antidepressant effect remained after 5 days of treatment with 3’-dA. Unlike the psycho-stimulants, 3’-dA did not show a hyperactive effect in the open field test. After 45min or 5 days of treatment, 3’-dA enhanced GluR1 S845 phosphorylation in both the PFC and HIP. In addition, after 45min of treatment, 3’-dA significantly up-regulated GluR1 S845 phosphorylation and GluR1, but not GluR2 levels, at the synapses in the PFC. After 5 days of treatment, 3’-dA significantly enhanced GluR1 S845 phosphorylation and GluR1, but not GluR2, at the synapses in the PFC and HIP. Moreover, the AMPA-specific antagonist GYKI 52466 was able to block the rapid antidepressant effects of 3’-dA. Conclusion: This study identified 3’-dA as a novel rapid antidepressant with clinical potential and multiple beneficial mechanisms, particularly in regulating the prefrontal AMPA receptor signaling pathway. PMID:26443809

  7. Biochemical Stimulus-Based Strategies for Meniscus Tissue Engineering and Regeneration

    Science.gov (United States)

    Chen, Mingxue; Guo, Weimin; Gao, Shunag; Hao, Chunxiang; Shen, Shi; Zhang, Zengzeng; Wang, Zhenyong; Wang, Zehao; Li, Xu; Jing, Xiaoguang; Zhang, Xueliang; Yuan, Zhiguo; Wang, Mingjie; Zhang, Yu; Peng, Jiang; Wang, Aiyuan; Wang, Yu; Sui, Xiang

    2018-01-01

    Meniscus injuries are very common and still pose a challenge for the orthopedic surgeon. Meniscus injuries in the inner two-thirds of the meniscus remain incurable. Tissue-engineered meniscus strategies seem to offer a new approach for treating meniscus injuries with a combination of seed cells, scaffolds, and biochemical or biomechanical stimulation. Cell- or scaffold-based strategies play a pivotal role in meniscus regeneration. Similarly, biochemical and biomechanical stimulation are also important. Seed cells and scaffolds can be used to construct a tissue-engineered tissue; however, stimulation to enhance tissue maturation and remodeling is still needed. Such stimulation can be biomechanical or biochemical, but this review focuses only on biochemical stimulation. Growth factors (GFs) are one of the most important forms of biochemical stimulation. Frequently used GFs always play a critical role in normal limb development and growth. Further understanding of the functional mechanism of GFs will help scientists to design the best therapy strategies. In this review, we summarize some of the most important GFs in tissue-engineered menisci, as well as other types of biological stimulation. PMID:29581987

  8. Rapid Isolation and Susceptibility Testing of Leptospira spp. Using a New Solid Medium, LVW Agar

    Science.gov (United States)

    Wuthiekanun, Vanaporn; Amornchai, Premjit; Paris, Daniel H.; Langla, Sayan; Thaipadunpanit, Janjira; Chierakul, Wirongrong; Smythe, Lee D.; White, Nicholas J.; Day, Nicholas P. J.; Peacock, Sharon J.

    2013-01-01

    Pathogenic Leptospira spp., the causative agents of leptospirosis, are slow-growing Gram-negative spirochetes. Isolation of Leptospira from clinical samples and testing of antimicrobial susceptibility are difficult and time-consuming. Here, we describe the development of a new solid medium that facilitates more-rapid growth of Leptospira spp. and the use of this medium to evaluate the Etest's performance in determining antimicrobial MICs to drugs in common use for leptospirosis. The medium was developed by evaluating the effects of numerous factors on the growth rate of Leptospira interrogans strain NR-20157. These included the type of base agar, the concentration of rabbit serum (RS), and the concentration and duration of CO2 incubation during the initial period of culture. The highest growth rate of NR-20157 was achieved using a Noble agar base supplemented with 10% RS (named LVW agar), with an initial incubation at 30°C in 5% CO2 for 2 days prior to continuous culture in air at 30°C. These conditions were used to develop the Etest for three species, L. interrogans (NR-20161), L. kirschnerii (NR-20327), and L. borgpetersenii (NR-20151). The MICs were read on day 7 for all samples. The Etest was then performed on 109 isolates of pathogenic Leptospira spp. The MIC90 values for penicillin G, doxycycline, cefotaxime, ceftriaxone, and chloramphenicol were 0.64 units/ml and 0.19, 0.047, 0.5, and 2 μg/ml, respectively. The use of LVW agar, which enables rapid growth, isolation of single colonies, and simple antimicrobial susceptibility testing for Leptospira spp., provides an opportunity for new areas of fundamental and applied research. PMID:23114772

  9. Thermodynamically consistent Bayesian analysis of closed biochemical reaction systems

    Directory of Open Access Journals (Sweden)

    Goutsias John

    2010-11-01

    Full Text Available Abstract Background Estimating the rate constants of a biochemical reaction system with known stoichiometry from noisy time series measurements of molecular concentrations is an important step for building predictive models of cellular function. Inference techniques currently available in the literature may produce rate constant values that defy necessary constraints imposed by the fundamental laws of thermodynamics. As a result, these techniques may lead to biochemical reaction systems whose concentration dynamics could not possibly occur in nature. Therefore, development of a thermodynamically consistent approach for estimating the rate constants of a biochemical reaction system is highly desirable. Results We introduce a Bayesian analysis approach for computing thermodynamically consistent estimates of the rate constants of a closed biochemical reaction system with known stoichiometry given experimental data. Our method employs an appropriately designed prior probability density function that effectively integrates fundamental biophysical and thermodynamic knowledge into the inference problem. Moreover, it takes into account experimental strategies for collecting informative observations of molecular concentrations through perturbations. The proposed method employs a maximization-expectation-maximization algorithm that provides thermodynamically feasible estimates of the rate constant values and computes appropriate measures of estimation accuracy. We demonstrate various aspects of the proposed method on synthetic data obtained by simulating a subset of a well-known model of the EGF/ERK signaling pathway, and examine its robustness under conditions that violate key assumptions. Software, coded in MATLAB®, which implements all Bayesian analysis techniques discussed in this paper, is available free of charge at http://www.cis.jhu.edu/~goutsias/CSS%20lab/software.html. Conclusions Our approach provides an attractive statistical methodology for

  10. Biochemical toxicology of environmental agents

    International Nuclear Information System (INIS)

    Bruin, A. de

    1976-01-01

    A thorough and up-to-date account of the molecular-biological aspects of harmful agents - both chemical and physical - is given. This current treatise is principally intended to serve as an informative reference work for researchers in various areas of the field. In the pursuit of this aim, a devision of the entire field into 42 chapters has been made. Each chapter starts with a short introductory account dealing with the biochemical essentials of the particular subject. Radiation effects are discussed briefly at the end of each treatise. In order to make the treatise useful as a source book, a substantial collection of pertinent literature references is provided which are numbered in order of citation in the text. Initial chapters are devoted to the metabolic fate of the major classes of xenobiotic compounds. Peripheral topics, closely related to metabolism and dealing with modification of xenobiotic-metabolizing ability, as well as interaction phenomena follow (chs. 5-8). Subjects that draw heavily on the practical field of occupational hygiene are dealt with in chapters 9 and 10. The systematic treatment of how chemical and physical agents interact with the various biochemical and enzymatic systems they encounter during their passage through the organism occupies quantitatively the main part of the book (chs. 11-36). Finally, radiation biochemistry is discussed from the viewpoint of its high degree of scientific advancement, and secondly because the type of biochemical changes produced in vivo by X-rays closely parallel those evoked by chemical agents

  11. Enzyme and biochemical producing fungi

    DEFF Research Database (Denmark)

    Lübeck, Peter Stephensen; Lübeck, Mette; Nilsson, Lena

    2010-01-01

    factories for sustainable production of important molecules. For developing fungi into efficient cell factories, the project includes identification of important factors that control the flux through the pathways using metabolic flux analysis and metabolic engineering of biochemical pathways....

  12. Risk of iatrogenic human immunodeficiency virus infection through transfusion of blood tested by inappropriately stored or expired rapid antibody assays in a Zambian hospital

    NARCIS (Netherlands)

    Consten, E. C.; van der Meer, J. T.; de Wolf, F.; Heij, H. A.; Henny, P. C.; van Lanschot, J. J.

    1997-01-01

    BACKGROUND: The purpose of this study was to estimate the risk of human immunodeficiency virus (HIV) infection via the transfusion of blood tested by inappropriately stored or expired rapid antibody assays in Zambia. STUDY DESIGN AND METHODS: Surgical patients (n = 370) were tested with antibody

  13. Detailed analysis of the supermarket task included on the Japanese version of the Rapid Dementia Screening Test.

    Science.gov (United States)

    Moriyama, Yasushi; Yoshino, Aihide; Muramatsu, Taro; Mimura, Masaru

    2017-05-01

    The supermarket task, which is included in the Japanese version of the Rapid Dementia Screening Test, requires the quick (1 min) generation of words for things that can be bought in a supermarket. Cluster size and switches are investigated during this task. We investigated how the severity of dementia related to cluster size and switches on the supermarket task in patients with Alzheimer's disease. We administered the Japanese version of the Rapid Dementia Screening Test to 250 patients with very mild to severe Alzheimer's disease and to 49 healthy volunteers. Patients had Mini-Mental State Examination scores from 12 to 26 and Clinical Dementia Rating scale scores from 0.5 to 3. Patients were divided into four groups based on their Clinical Dementia Rating score (0.5, 1, 2, 3). We performed statistical analyses between the four groups and control subjects based on cluster size and switch scores on the supermarket task. The score for cluster size and switches deteriorated according to the severity of dementia. Moreover, for subjects with a Clinical Dementia Rating score of 0.5, cluster size was impaired, but switches were intact. Our findings indicate that the scores for cluster size and switches on the supermarket task may be useful for detecting the severity of symptoms of dementia in patients with Alzheimer's disease. © 2016 The Authors. Psychogeriatrics © 2016 Japanese Psychogeriatric Society.

  14. Ouroboros - Playing A Biochemical

    Directory of Open Access Journals (Sweden)

    D. T. Rodrigues

    2014-08-01

    Full Text Available Ouroboros: Playing A Biochemical RODRIGUES,D.T.1,2;GAYER, M.C.1,2; ESCOTO, D.F.1; DENARDIN, E.L.G.2, ROEHRS, R.1,2 1Interdisciplinary Research Group on Teaching Practice, Graduate Program in Biochemistry, Unipampa, RS, Brazil 2Laboratory of Physicochemical Studies and Natural Products, Post Graduate Program in Biochemistry, Unipampa, RS, Brazil Introduction: Currently, teachers seek different alternatives to enhance the teaching-learning process. Innovative teaching methodologies are increasingly common tools in educational routine. The use of games, electronic or conventional, is an effective tool to assist in learning and also to raise the social interaction between students. Objective: In this sense our work aims to evaluate the card game and "Ouroboros" board as a teaching and learning tool in biochemistry for a graduating class in Natural Sciences. Materials and methods: The class gathered 22 students of BSc in Natural Sciences. Each letter contained a question across the board that was drawn to a group to answer within the allotted time. The questions related concepts of metabolism, organic and inorganic chemical reactions, bioenergetics, etc.. Before the game application, students underwent a pre-test with four issues involving the content that was being developed. Soon after, the game was applied. Then again questions were asked. Data analysis was performed from the ratio of the number of correct pre-test and post-test answers. Results and discussion: In the pre-test 18.1% of the students knew all issues, 18.1% got 3 correct answers, 40.9% answered only 2 questions correctly and 22.7% did not hit any. In post-test 45.4% answered all the questions right, 31.8% got 3 questions and 22.7% got 2 correct answers. The results show a significant improvement of the students about the field of content taught through the game. Conclusion: Generally, traditional approaches of chemistry and biochemistry are abstract and complex. Thus, through games

  15. Probabilistic sensitivity analysis of biochemical reaction systems.

    Science.gov (United States)

    Zhang, Hong-Xuan; Dempsey, William P; Goutsias, John

    2009-09-07

    Sensitivity analysis is an indispensable tool for studying the robustness and fragility properties of biochemical reaction systems as well as for designing optimal approaches for selective perturbation and intervention. Deterministic sensitivity analysis techniques, using derivatives of the system response, have been extensively used in the literature. However, these techniques suffer from several drawbacks, which must be carefully considered before using them in problems of systems biology. We develop here a probabilistic approach to sensitivity analysis of biochemical reaction systems. The proposed technique employs a biophysically derived model for parameter fluctuations and, by using a recently suggested variance-based approach to sensitivity analysis [Saltelli et al., Chem. Rev. (Washington, D.C.) 105, 2811 (2005)], it leads to a powerful sensitivity analysis methodology for biochemical reaction systems. The approach presented in this paper addresses many problems associated with derivative-based sensitivity analysis techniques. Most importantly, it produces thermodynamically consistent sensitivity analysis results, can easily accommodate appreciable parameter variations, and allows for systematic investigation of high-order interaction effects. By employing a computational model of the mitogen-activated protein kinase signaling cascade, we demonstrate that our approach is well suited for sensitivity analysis of biochemical reaction systems and can produce a wealth of information about the sensitivity properties of such systems. The price to be paid, however, is a substantial increase in computational complexity over derivative-based techniques, which must be effectively addressed in order to make the proposed approach to sensitivity analysis more practical.

  16. Characterizing multistationarity regimes in biochemical reaction networks.

    Directory of Open Access Journals (Sweden)

    Irene Otero-Muras

    Full Text Available Switch like responses appear as common strategies in the regulation of cellular systems. Here we present a method to characterize bistable regimes in biochemical reaction networks that can be of use to both direct and reverse engineering of biological switches. In the design of a synthetic biological switch, it is important to study the capability for bistability of the underlying biochemical network structure. Chemical Reaction Network Theory (CRNT may help at this level to decide whether a given network has the capacity for multiple positive equilibria, based on their structural properties. However, in order to build a working switch, we also need to ensure that the bistability property is robust, by studying the conditions leading to the existence of two different steady states. In the reverse engineering of biological switches, knowledge collected about the bistable regimes of the underlying potential model structures can contribute at the model identification stage to a drastic reduction of the feasible region in the parameter space of search. In this work, we make use and extend previous results of the CRNT, aiming not only to discriminate whether a biochemical reaction network can exhibit multiple steady states, but also to determine the regions within the whole space of parameters capable of producing multistationarity. To that purpose we present and justify a condition on the parameters of biochemical networks for the appearance of multistationarity, and propose an efficient and reliable computational method to check its satisfaction through the parameter space.

  17. Rapid testing of pulse transformers

    Science.gov (United States)

    Grillo, J.

    1980-01-01

    Quality-control testing of pulse transformers is speeded up by method for determining rise time and droop. Instead of using oscilloscope and square-wave generator to measure these characteristics directly, method uses voltmeter and sine-wave generator to measure them indirectly in about one-tenth time. Droop and rise time are determined by measuring input/output voltage ratio at just four frequencies.

  18. Evaluating the use of dedicated swab for rapid antigen detection ...

    African Journals Online (AJOL)

    Evaluating the use of dedicated swab for rapid antigen detection testing in group a ... African Journal of Clinical and Experimental Microbiology ... Several generations of rapid antigen detection tests (RADTs) have been developed to facilitate ...

  19. Design, development and evaluation of rK28-based point-of-care tests for improving rapid diagnosis of visceral leishmaniasis.

    Directory of Open Access Journals (Sweden)

    Sowmya Pattabhi

    Full Text Available BACKGROUND: Visceral leishmaniasis (VL is diagnosed by microscopic confirmation of the parasite in bone marrow, spleen or lymph node aspirates. These procedures are unsuitable for rapid diagnosis of VL in field settings. The development of rK39-based rapid diagnostic tests (RDT revolutionized diagnosis of VL by offering high sensitivity and specificity in detecting disease in the Indian subcontinent; however, these tests have been less reliable in the African subcontinent (sensitivity range of 75-85%, specificity of 70-92%. We have addressed limitations of the rK39 with a new synthetic polyprotein, rK28, followed by development and evaluation of two new rK28-based RDT prototype platforms. METHODOLOGY/PRINCIPAL FINDINGS: Evaluation of 62 VL-confirmed sera from Sudan provided sensitivities of 96.8% and 93.6% (95% CI = K28: 88.83-99.61%; K39: 84.30-98.21% and specificities of 96.2% and 92.4% (95% CI = K28: 90.53-98.95%; K39: 85.54-96.65% for rK28 and rK39, respectively. Of greater interest was the observation that individual VL sera with low rK39 reactivity often had much higher rK28 reactivity. This characteristic of the fusion protein was exploited in the development of rK28 rapid tests, which may prove to be crucial in detecting VL among patients with low rK39 antibody levels. Evaluation of two prototype lateral flow-based rK28 rapid tests on 53 VL patients in Sudan and 73 VL patients in Bangladesh provided promisingly high sensitivities (95.9% [95% CI = 88.46-99.1 in Sudan and 98.1% [95% CI = 89.93-99.95%] in Bangladesh compared to the rK39 RDT (sensitivities of 86.3% [95% CI = 76.25-93.23%] in Sudan and 88.7% [95% CI = 76.97-95.73%] in Bangladesh. CONCLUSIONS/SIGNIFICANCE: Our study compares the diagnostic accuracy of rK39 and rK28 in detecting active VL cases and our findings indicate that rK28 polyprotein has great potential as a serodiagnostic tool. A new rK28-based RDT will prove to be a valuable asset in

  20. Fluoranthene induced changes in photosynthetic pigments, biochemical compounds and enzymatic activities in two microalgal species: Chlorella vulgaris Beijerinck and Desmodesmus subspicatus Chodat

    Directory of Open Access Journals (Sweden)

    Miral Patel

    2014-02-01

    Full Text Available The photosynthetic pigments, biochemical and enzymatic activities in two freshwater microalgal species, Chlorella vulgaris and Desmodesmus subspicatus at different fluoranthene concentrations were compared with the control conditions. During 16-days of incubation period when treated with fluoranthene, both microalgal species exhibited variable amount of photosynthetic pigment, biochemical compounds and enzymatic activities. The addition of fluoranthene at concentrations ranged from 1.5 mg l-1; to 10 mg l-1; to microalgal cultures led to changes in all different metabolites but the patterns varied from species to species. Among the two species tested, pigment, biochemical and enzymatic contents were remarkably declined from 7 % to 95% in C. vulgaris. Moreover, all metabolites in D. subspicatus also diminishing significantly by 3% to 88% of fluoranthene doses (10ppm. These results suggest that fluoranthene-induced changes of pigments, biochemical and enzymatic variations in test microalgae, D. subspicatus and C. vulgaris, might reveal its resistance and ability to metabolize PAHs. At the same time, the PAH impact changes on different metabolic activities were higher at 12 and 16 days than at 4 and 8 days in treated microalgae. DOI: http://dx.doi.org/10.3126/ije.v3i1.9941 International Journal of Environment Vol.3(1 2014: 41-55