WorldWideScience

Sample records for rapid axial head

  1. CFD Simulation and Optimization of Very Low Head Axial Flow Turbine Runner

    Directory of Open Access Journals (Sweden)

    Yohannis Mitiku Tobo

    2015-10-01

    Full Text Available The main objective of this work is Computational Fluid Dynamics (CFD modelling, simulation and optimization of very low head axial flow turbine runner  to be used to drive  a centrifugal pump of turbine-driven pump. The ultimate goal of the optimization is to produce a power of 1kW at head less than 1m from flowing  river to drive centrifugal pump using mechanical coupling (speed multiplier gear directly. Flow rate, blade numbers, turbine rotational speed, inlet angle are parameters used in CFD modeling,  simulation and design optimization of the turbine runner. The computed results show that power developed by a turbine runner increases with increasing flow rate. Pressure inside the turbine runner increases with flow rate but, runner efficiency increases for some flow rate and almost constant thereafter. Efficiency and power developed by a runner drops quickly if turbine speed increases due to higher pressure losses and conversion of pressure energy to kinetic energy inside the runner. Increasing blade number increases power developed but, efficiency does not increase always. Efficiency increases for some blade number and drops down due to the fact that  change in direction of the relative flow vector at the runner exit, which decreases the net rotational momentum and increases the axial flow velocity.

  2. Using Tri-Axial Accelerometers to Assess the Dynamic Control of Head Posture During Gait

    Science.gov (United States)

    Lawrence, John H., III

    2003-01-01

    Long duration spaceflight is known to cause a variety of biomedical stressors to the astronaut. One of the more functionally destabilizing effects of spaceflight involves microgravity-induced changes in vestibular or balance control. Balance control requires the integration of the vestibular, visual, and proprioceptive systems. In the microgravity environment, the normal gravity vector present on Earth no longer serves as a reference for the balance control system. Therefore, adaptive changes occur to the vestibular system to affect control of body orientation with altered, or non-present, gravity and/or proprioceptive inputs. Upon return to a gravity environment, the vestibular system must re-incorporate the gravity vector and gravity-induced proprioceptive inputs into the balance control regime. The result is often a period of postural instability, which may also be associated with space motion sickness (oscillopsia, nausea, and vertigo). Previous studies by the JSC Neuroscience group have found that returning astronauts often employ alterations in gait mechanics to maintain postural control during gait. It is believed that these gait alterations are meant to decrease the transfer of heel strike shock energy to the head, thus limiting the contradictory head and eye movements that lead to gait instability and motion sickness symptoms. We analyzed pre- and post-spaceflight tri-axial accelerometer data from the NASA/MIR long duration spaceflight missions to assess the heel to head transfer of heel strike shock energy during locomotion. Up to seven gait sessions (three preflight, four postflight) of head and shank (lower leg) accelerometer data was previously collected from six astronauts who engaged in space flights of four to six months duration. In our analysis, the heel to head transmission of shock energy was compared using peak vertical acceleration (a), peak jerk (j) ratio, and relative kinetic energy (a). A host of generalized movement variables was produced

  3. Numerical analysis of head degrade law under cavitation condition of contra-rotating axial flow waterjet pump

    Science.gov (United States)

    Huang, D.; Pan, Z. Y.

    2015-01-01

    In order to study the flow-head characteristic curve, the SST turbulence model, homogeneous multiphase model and Rayleigh-Plesset equation were applied to simulate the cavitation characteristics in contra-rotating axial flow waterjet pump under different conditions based on ANSYS CFX software. The distribution of cavity, pressure coefficient of the blade at the design point under different cavitation conditions were obtained. The analysis results of flow field show that the vapour volume distribution on the impeller indicates that the vapour first appears at the leading edge of blade and then extends to the outlet of impeller with the reduction of Net Positive Suction Head Allowance (NPSHA). The present study illustrates that the main reason for the decline of the pump performance is the development of cavitation, and the simulation can truly reflect the cavitation performance of the contra-rotating axial flow waterjet pump.

  4. Experimental investigation of the influence of blade height and blade number on the performance of low head axial flow turbines

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Punit; Nestmann, Franz [Institute for Water and River Basin Management (IWG), University of Karlsruhe, Kaiser Str. 12, D 76128, Karlsruhe (Germany)

    2011-01-15

    Investigations regarding the influence of design parameters in low head axial flow turbines like blade profiles, blade height and blade number for micro-hydro application continue to be inadequate, even though there is a need and potential for the application of such turbines. This inadequacy provides a good ground to make a detailed experimental study to characterize these influences. The paper presents a holistic theoretical model that attempts to bring out a functionality of the internal performance parameters of the runner and attempts to establish a physical relationship between the two design parameters (blade height and blade number) and the performance parameters. The experimental results on 3 runners showed that with an increase in the number of blades, the efficiency of the runner dropped drastically due to the change in direction of the relative flow vector at the runner exit, which decreased the net rotational momentum and increased the axial flow velocity. The decrease of blade height on the other hand decreased the overall runner loss coefficient quite drastically but this could not result in major performance gains. The study concluded that the influence of blade number is more dominating compared to that of the blade height and that choice of blade number should be carefully made. On the hydraulic level, the study found interesting effects like the slip phenomenon and loss mechanisms within the runner. The paper also looks into the possible errors within the theoretical model developed and the extent of their influence on the conclusions. The paper suggests more experimental studies to separately study the effects of blade number and blade height. It further makes a strong case to initiate a computational work to validate all the experimental findings, fill the gaps in the theoretical model and use it as an optimization and standardization tool for axial flow turbines in the specialized application of micro-hydro. (author)

  5. Size-specific, scanner-independent organ dose estimates in contiguous axial and helical head CT examinations.

    Science.gov (United States)

    McMillan, Kyle; Bostani, Maryam; Cagnon, Chris; Zankl, Maria; Sepahdari, Ali R; McNitt-Gray, Michael

    2014-12-01

    AAPM Task Group 204 introduced size-specific dose estimates for pediatric and adult patients undergoing body CT examinations. This investigation extends that work to head CT exams by using Monte Carlo simulations to develop size-specific, scanner-independent CTDIvol-to-organ-dose conversion coefficients. Using eight patient models from the GSF family of voxelized phantoms, dose to the brain and lens of the eye was estimated using Monte Carlo simulations of contiguous axial and helical scans for 64-slice multidetector CT scanners from four major manufacturers. For each patient model and scan mode, scanner-independent CTDIvol-to-organ-dose conversion coefficients were calculated by normalizing organ dose by scanner-specific 16 cm CTDIvol values and averaging across all scanners. Head size was measured using both geometric and attenuation-based size metrics. Head perimeter and effective diameter (ED), both geometric size metrics, were measured directly from the GSF data at the first slice superior to the eyes. Because the GSF models' pixel data are provided in terms of organ identification numbers instead of CT numbers, an indirect estimate of water equivalent diameter (WED), an attenuation-based size metric, was determined based on the relationships between WED and both ED and perimeter for a sample of patient data. Correlations between CTDIvol-to-organ-dose conversion coefficients and the various patient size metrics were then explored. The analysis of the patient data revealed a best-fit linear relationship (R(2) of 0.87) between ED and WED across a wide variety of patient sizes. Using this relationship along with ED determined from the GSF data, WED was estimated for each GSF model. An exponential relationship between CTDIvol normalized organ dose and WED was observed for both contiguous axial and helical scanning. For head perimeter and ED measured directly from the GSF data, an exponential relationship between CTDIvol normalized organ dose and patient size was

  6. Microwave Hematoma Detector for the Rapid Assessment of Head Injuries

    Energy Technology Data Exchange (ETDEWEB)

    Hadded, W.; Chang, J.; Rosenbury, T.; Dallum, G.; Welsch, P.; Scott, D.; Duarte, D.; Acevedo-Bolton, V.

    2000-02-11

    A non-invasive microwave device for the detection of epi/subdural hemorrhaging (hematoma) is under current development. The final device will be highly portable and allow real time assessment of head injuries, thereby satisfying early detection needs of the field technician as well as providing a tool for repetitious monitoring of high-risk individuals. The device will adopt the advanced technology of micropower impulse radar (MIR) which is a state of the art low cost ultra wide band (UWB) microwave radar developed here at LLNL. It will consist of a MIR transmitting and receiving module, a computer based signal processing module, and a device-to-patient signal coupling module--the UWB antenna. The prototype design is being guided by the needs of the patient and the practitioner along with the prerequisites of the technology including issues such as the specificity of the device, efficacy of diagnosis, accuracy, robustness, and patient comfort. The prototype development follows a concurrent approach which .includes experiments designed to evaluate requirements of the radar and antenna design, phantom development to facilitate laboratory investigations, and investigation into the limits of adapting pre-existing non-medical MIR devices to medical applications. This report will present the accomplishments and project highlights to date in the fiscal year 1999. Future project projections will also be discussed.

  7. Rapid MRI evaluation of acute intracranial hemorrhage in pediatric head trauma

    Energy Technology Data Exchange (ETDEWEB)

    Ryan, Maura E.; Jaju, Alok [Northwestern University Feinberg School of Medicine, Department of Radiology, Chicago, IL (United States); Ann and Robert H. Lurie Children' s Hospital of Chicago, Department of Medical Imaging, Chicago, IL (United States); Ciolino, Jody D. [Northwestern University, Biostatistics Collaboration Center, Department of Preventive Medicine Feinberg School of Medicine, Chicago, IL (United States); Alden, Tord [Northwestern University Feinberg School of Medicine, Department of Neurological Surgery, Chicago, IL (United States); Ann and Robert H. Lurie Children' s Hospital of Chicago, Department of Neurosurgery, Chicago, IL (United States)

    2016-08-15

    Rapid MRI with ultrafast T2 sequences can be performed without sedation and is often used in place of computed tomography (CT) to evaluate pediatric patients for indications such as hydrocephalus. This study investigated the sensitivity of rapid magnetic resonance imaging (MRI) for detection and follow-up of acute intracranial hemorrhage in comparison to CT, which is commonly the first-line imaging. Patients presenting to a pediatric hospital with acute intracranial hemorrhage on CT and follow-up rapid MRI within 48 h were included. Rapid MRI studies consisted of three plane ultrafast T2 sequences either with or without axial gradient echo (GRE) sequences. Identification of hemorrhage on rapid MRI was assessed by readers both blinded and unblinded to prior CT results. One hundred two acute hemorrhages in 61 patients were identified by CT. Rapid MRI detection of subdural and epidural hemorrhages was modest in the absence of prior CT for comparison (sensitivity 61-74 %), but increased with review of the prior CT (sensitivity 80-86 %). Hemorrhage size was a significant predictor of detection (p < 0.0001). Three plane fast T2 images alone without GRE sequences were poor at detecting subarachnoid hemorrhage (sensitivity 10-25 %); rapid MRI with GRE sequences identified the majority of subarachnoid hemorrhage (sensitivity 71-93 %). GRE modestly increased detection of other extra-axial hemorrhages. Rapid MRI with GRE sequences is sensitive for most acute intracranial hemorrhages only when a prior CT is available for review. Rapid MRI is not adequate to replace CT in initial evaluation of intracranial hemorrhages but may be helpful in follow-up of known hemorrhages. (orig.)

  8. Quasi-Static Compression and Low-Velocity Impact Behavior of Tri-Axial Bio-Composite Structural Panels Using a Spherical Head

    Science.gov (United States)

    Li, Jinghao; Hunt, John F; Gong, Shaoqin; Cai, Zhiyong

    2017-01-01

    This paper presents experimental results of both quasi-static compression and low-velocity impact behavior for tri-axial bio-composite structural panels using a spherical load head. Panels were made having different core and face configurations. The results showed that panels made having either carbon fiber fabric composite faces or a foam-filled core had significantly improved impact and compressive performance over panels without either. Different localized impact responses were observed based on the location of the compression or impact relative to the tri-axial structural core; the core with a smaller structural element had better impact performance. Furthermore, during the early contact phase for both quasi-static compression and low-velocity impact tests, the panels with the same configuration had similar load-displacement responses. The experimental results show basic compression data could be used for the future design and optimization of tri-axial bio-composite structural panels for potential impact applications. PMID:28772542

  9. Quasi-Static Compression and Low-Velocity Impact Behavior of Tri-Axial Bio-Composite Structural Panels Using a Spherical Head

    Directory of Open Access Journals (Sweden)

    Jinghao Li

    2017-02-01

    Full Text Available This paper presents experimental results of both quasi-static compression and low-velocity impact behavior for tri-axial bio-composite structural panels using a spherical load head. Panels were made having different core and face configurations. The results showed that panels made having either carbon fiber fabric composite faces or a foam-filled core had significantly improved impact and compressive performance over panels without either. Different localized impact responses were observed based on the location of the compression or impact relative to the tri-axial structural core; the core with a smaller structural element had better impact performance. Furthermore, during the early contact phase for both quasi-static compression and low-velocity impact tests, the panels with the same configuration had similar load-displacement responses. The experimental results show basic compression data could be used for the future design and optimization of tri-axial bio-composite structural panels for potential impact applications.

  10. Rapid Destruction of the Humeral Head Caused by Subchondral Insufficiency Fracture: A Report of Two Cases

    Directory of Open Access Journals (Sweden)

    Kenichi Goshima

    2015-01-01

    Full Text Available Rapidly destructive arthritis (RDA of the shoulder is a rare disease. Here, we report two cases, with different destruction patterns, which were most probably due to subchondral insufficiency fractures (SIFs. Case 1 involved a 77-year-old woman with right shoulder pain. Rapid destruction of both the humeral head and glenoid was seen within 1 month of the onset of shoulder pain. We diagnosed shoulder RDA and performed a hemiarthroplasty. Case 2 involved a 74-year-old woman with left shoulder pain. Humeral head collapse was seen within 5 months of pain onset, without glenoid destruction. Magnetic resonance imaging showed a bone marrow edema pattern with an associated subchondral low-intensity band, typical of SIF. Total shoulder arthroplasty was performed in this case. Shoulder RDA occurs as a result of SIF in elderly women; the progression of the joint destruction is more rapid in cases with SIFs of both the humeral head and the glenoid. Although shoulder RDA is rare, this disease should be included in the differential diagnosis of acute onset shoulder pain in elderly female patients with osteoporosis and persistent joint effusion.

  11. How Lovebirds Maneuver Rapidly Using Super-Fast Head Saccades and Image Feature Stabilization.

    Directory of Open Access Journals (Sweden)

    Daniel Kress

    Full Text Available Diurnal flying animals such as birds depend primarily on vision to coordinate their flight path during goal-directed flight tasks. To extract the spatial structure of the surrounding environment, birds are thought to use retinal image motion (optical flow that is primarily induced by motion of their head. It is unclear what gaze behaviors birds perform to support visuomotor control during rapid maneuvering flight in which they continuously switch between flight modes. To analyze this, we measured the gaze behavior of rapidly turning lovebirds in a goal-directed task: take-off and fly away from a perch, turn on a dime, and fly back and land on the same perch. High-speed flight recordings revealed that rapidly turning lovebirds perform a remarkable stereotypical gaze behavior with peak saccadic head turns up to 2700 degrees per second, as fast as insects, enabled by fast neck muscles. In between saccades, gaze orientation is held constant. By comparing saccade and wingbeat phase, we find that these super-fast saccades are coordinated with the downstroke when the lateral visual field is occluded by the wings. Lovebirds thus maximize visual perception by overlying behaviors that impair vision, which helps coordinate maneuvers. Before the turn, lovebirds keep a high contrast edge in their visual midline. Similarly, before landing, the lovebirds stabilize the center of the perch in their visual midline. The perch on which the birds land swings, like a branch in the wind, and we find that retinal size of the perch is the most parsimonious visual cue to initiate landing. Our observations show that rapidly maneuvering birds use precisely timed stereotypic gaze behaviors consisting of rapid head turns and frontal feature stabilization, which facilitates optical flow based flight control. Similar gaze behaviors have been reported for visually navigating humans. This finding can inspire more effective vision-based autopilots for drones.

  12. How Lovebirds Maneuver Rapidly Using Super-Fast Head Saccades and Image Feature Stabilization

    Science.gov (United States)

    Kress, Daniel; van Bokhorst, Evelien; Lentink, David

    2015-01-01

    Diurnal flying animals such as birds depend primarily on vision to coordinate their flight path during goal-directed flight tasks. To extract the spatial structure of the surrounding environment, birds are thought to use retinal image motion (optical flow) that is primarily induced by motion of their head. It is unclear what gaze behaviors birds perform to support visuomotor control during rapid maneuvering flight in which they continuously switch between flight modes. To analyze this, we measured the gaze behavior of rapidly turning lovebirds in a goal-directed task: take-off and fly away from a perch, turn on a dime, and fly back and land on the same perch. High-speed flight recordings revealed that rapidly turning lovebirds perform a remarkable stereotypical gaze behavior with peak saccadic head turns up to 2700 degrees per second, as fast as insects, enabled by fast neck muscles. In between saccades, gaze orientation is held constant. By comparing saccade and wingbeat phase, we find that these super-fast saccades are coordinated with the downstroke when the lateral visual field is occluded by the wings. Lovebirds thus maximize visual perception by overlying behaviors that impair vision, which helps coordinate maneuvers. Before the turn, lovebirds keep a high contrast edge in their visual midline. Similarly, before landing, the lovebirds stabilize the center of the perch in their visual midline. The perch on which the birds land swings, like a branch in the wind, and we find that retinal size of the perch is the most parsimonious visual cue to initiate landing. Our observations show that rapidly maneuvering birds use precisely timed stereotypic gaze behaviors consisting of rapid head turns and frontal feature stabilization, which facilitates optical flow based flight control. Similar gaze behaviors have been reported for visually navigating humans. This finding can inspire more effective vision-based autopilots for drones. PMID:26107413

  13. How Lovebirds Maneuver Rapidly Using Super-Fast Head Saccades and Image Feature Stabilization.

    Science.gov (United States)

    Kress, Daniel; van Bokhorst, Evelien; Lentink, David

    2015-01-01

    Diurnal flying animals such as birds depend primarily on vision to coordinate their flight path during goal-directed flight tasks. To extract the spatial structure of the surrounding environment, birds are thought to use retinal image motion (optical flow) that is primarily induced by motion of their head. It is unclear what gaze behaviors birds perform to support visuomotor control during rapid maneuvering flight in which they continuously switch between flight modes. To analyze this, we measured the gaze behavior of rapidly turning lovebirds in a goal-directed task: take-off and fly away from a perch, turn on a dime, and fly back and land on the same perch. High-speed flight recordings revealed that rapidly turning lovebirds perform a remarkable stereotypical gaze behavior with peak saccadic head turns up to 2700 degrees per second, as fast as insects, enabled by fast neck muscles. In between saccades, gaze orientation is held constant. By comparing saccade and wingbeat phase, we find that these super-fast saccades are coordinated with the downstroke when the lateral visual field is occluded by the wings. Lovebirds thus maximize visual perception by overlying behaviors that impair vision, which helps coordinate maneuvers. Before the turn, lovebirds keep a high contrast edge in their visual midline. Similarly, before landing, the lovebirds stabilize the center of the perch in their visual midline. The perch on which the birds land swings, like a branch in the wind, and we find that retinal size of the perch is the most parsimonious visual cue to initiate landing. Our observations show that rapidly maneuvering birds use precisely timed stereotypic gaze behaviors consisting of rapid head turns and frontal feature stabilization, which facilitates optical flow based flight control. Similar gaze behaviors have been reported for visually navigating humans. This finding can inspire more effective vision-based autopilots for drones.

  14. Evaluation of Optic Nerve Head Parameters and Retinal Nerve Fiber Layer Thickness in Axial Myopia Using SD OCT.

    Science.gov (United States)

    AttaAllah, Heba Radi; Omar, Ismail Ahmed Nagib; Abdelhalim, Ahmed Shawkat

    2017-12-01

    The purpose of this research was to study the effect of increased axial myopia, in non-glaucomatous eyes, and its correlation with ONH parameters, and RNFL thickness, using Cirrus HD 4000 SD-OCT. The myopia group included 86 eyes of 86 patients, while the control group involved 92 eyes of 92 patients, attending the Ophthalmology Outpatient Clinic in Minia University Hospital, between November 2013 and March 2015. ONH parameters and peripapillary RNFL thickness measurement were evaluated by using SD-OCT, selecting the standard optic disc cube 200 × 200. The mean age of the myopia group was (36.55 ± 9.44), the mean spherical equivalent was (-12.70 ± 3.87 D), and the mean axial length was (27.88 ± 1.92 mm). The control group had mean age of (34.82 ± 8.87), mean spherical equivalent of -0.65 ± 0.41 D, and mean AL of (22.16 ± 0.82). A significant difference was reported between the two groups, regarding disc area (p = 0.01), rim area (p = 0.001), vertical C/D (p = 0.01), average C/D ratio (p = 0.001), average and temporal RNFL thickness (p = 0.0001, p = 0.001, respectively). A significant difference was found between highly myopic non-glaucomatous eyes and the control group, regarding ONH parameters and RNFL thickness as measured by SD-OCT. As OCT magnification adjusted ONH parameters were larger, global and the temporal RNEL were thicker in the myopia group, those magnification adjusted parameters helped in an accurate evaluation of ONH and RNFL in highly myopic eyes, in order to avoid misdiagnosis of glaucoma in such eyes.

  15. Effects of rapid maxillary expansion on head posture, postural stability, and fall risk

    Directory of Open Access Journals (Sweden)

    Fatih Celebi

    2017-01-01

    Full Text Available Objective: The aim of this study was to investigate the effects of rapid maxillary expansion (RME on head posture, postural stability, and fall risk. Materials and Methods: A sample of 51 adolescent patients was randomly divided into two groups. In the first group, which consisted of 28 patients (15 females and 13 males, RME was performed as a part of routine orthodontic treatment. The remaining 23 individuals (12 females and 11 males served as the control group. Lateral cephalometric radiographs taken in natural head position, postural stability, and fall risk scores were obtained during the first visit. They were repeated on average 3.8 months and 3.5 months later for the study and control groups, respectively. The changes were analyzed using the Wilcoxon signed-rank test, paired samples t-test, Mann–Whitney U-test, and independent samples t-test. Results: As a result of RME, a statistically significant decrease was detected in the fall risk score (P < 0.05 in the study group, while the head position and postural stability remained unchanged. For the control group, no significant changes were observed in all measurements. Conclusions: The result of the present study suggests that RME has a capacity of improving fall risk.

  16. Changes in head posture after rapid maxillary expansion in patients with nasopharyngeal obstruction

    Directory of Open Access Journals (Sweden)

    Kjurchieva-Chuchkova G

    2016-09-01

    Full Text Available Introduction: Nasopharyngeal obstruction is an important etiologic factor in the development of an extreme vertical growth facial pattern, and insufficient transversal growth of the maxilla. The treatment outcomes associated with rapid maxillary expansion in the literature are mainly discussed in terms of changes in dentofacial morphology, without special reference to changes in the pharyngeal airway, the position of the mandible, hyoid bone and the tongue. Aim: The aim of this study was to evaluate the effects of rapid maxillary expansion (RME, on changes in head posture and airway dimension. Materials and methods: The cephalometric evaluation was conducted on thirty lateral cephalograms of patients with nasopharyngeal obstruction (mean age 9.11 years; standard deviation (SD ± 2.0; range 8-14 years treated with appliance for rapid maxillary expansion. Patients were randomly divided into two groups: 1 study group comprised of 15 patients treated with RME immediately after the first visit; 2 a control group comprised of 15 subjects monitored for approximately 12 months prior to commencing therapy, who became untreated controls. Lateral cephalograms, taken in the natural head position, were obtained at the first visit and 6 months later for all subjects. Six angular measurements were measured to describe craniocervical angulation, and five linear measurements were measured to describe airway dimension. Results: The investigated group treated with RME shows a statistically significant decrease in craniocervical angulation, especially at the angle of interaction between palatal plane and the tangent odontoid processus (4.07 degrees, for PP/OPT angle and angle interaction between palatal plane and the tangent of cervical vertebra (4.95 degrees for PP/CVT angle. Airway dimension in the treated group increased, especially at the levels PNS-ad1 (2.52 mm, ve-pve (2.97 mm, and uv-puv (2.88 mm. No significant changes were observed in the control group

  17. Rapid hyperfractionated radiotherapy. Clinical results in 178 advanced squamous cell carcinomas of the head and neck

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, T.D.; Demange, L.; Froissart, D.; Panis, X.; Loirette, M.

    1985-07-01

    The authors present a series of 178 patients with Stage III or IV squamous cell carcinoma of the head and neck treated by rapid irradiation using multiple and small fractions per day. An initial group of 91 patients (G1) received a total dose of 72 Gy in 80 sessions and 10 days, according to the following split course schedule: J1 to J5, 36 Gy in 40 sessions, eight daily fractions of .9 Gy separated by 2 hours; J6 to J20, rest period; J21 to J25, same as in J1 except that the spinal cord was shielded. This protocol was altered for the following 87 patients (G2) by lessening the total dose to 60 to 66 Gy and the number of fractions to 60. The rest period was lengthened to 4 weeks. All patients but five completed the whole program and the minimal follow-up period was 24 months. At the end of irradiation, 121 patients achieved a total remission, but local recurrences occurred in 56%. Moreover, acute intolerance was considered as severe in 34% of G1 patients, and included extensive mucosal necrosis and bleeding. Although this rate was significantly reduced in G2 patients, late complications were observed in 20 of the 25 survivors, and included trismus, cervical sclerosis, and recurrent laryngeal edema. The crude survival rate is 13% at 2 years. Although this study was not randomized, this particular type of accelerated and hyperfractionated combination of irradiation did not really improve the clinical results in advanced carcinoma of the head and neck. Other schedules and probably other tumors, less extended, should be tested.

  18. Rapid estimation of topsoil hydraulic properties from coupled inversion of TDR data during falling head infiltration

    Science.gov (United States)

    Mboh, C.; Huisman, J. A.; Vereecken, H.

    2010-12-01

    enables accurate estimation of the depths of ponded water at the soil surface. Accurate monitoring of ponded depths of water is important for many applications, including flood irrigation management and flood control by earth dams. Moreover as it is not necessary to manually measure the ponding depths, the coupled approach offers the possibility of automatic monitoring of falling head infiltration at several rings at several locations in the field based on TDR multiplexing. This can lead to rapid and cost effective estimation of topsoil hydraulic properties.

  19. Axial myopathy

    DEFF Research Database (Denmark)

    Witting, Nanna; Andersen, Linda K; Vissing, John

    2016-01-01

    musculature involvement in the majority of myopathies in which paraspinal musculature was examined. Even in diseases named after a certain pattern of non-axial muscle affection, such as facioscapulohumeral and limb girdle muscular dystrophies, affection of the axial musculature was often severe and early...

  20. Enthesitis in patients with psoriatic arthritis, axial spondyloarthritis and healthy subjects assessed by ‘head-to-toe’ whole-body MRI and clinical examination

    DEFF Research Database (Denmark)

    Poggenborg, René Panduro; Eshed, Iris; Østergaard, Mikkel

    2015-01-01

    OBJECTIVES: To investigate the ability of whole-body MRI (WBMRI) to detect axial and peripheral enthesitis in patients with psoriatic arthritis (PsA) and axial spondyloarthritis (axSpA), and in healthy subjects (HS). Furthermore, to develop MRI enthesitis indices based on WBMRI and validate...... and patient global (ρ=0.29-0.31, pimaging modality for evaluation of enthesitis in patients with PsA and axSpA, but requires further investigation before clinical use....

  1. Head-to-toe whole-body MRI in psoriatic arthritis, axial spondyloarthritis and healthy subjects: first steps towards global inflammation and damage scores of peripheral and axial joints.

    Science.gov (United States)

    Poggenborg, René Panduro; Pedersen, Susanne Juhl; Eshed, Iris; Sørensen, Inge Juul; Møller, Jakob M; Madsen, Ole Rintek; Thomsen, Henrik S; Østergaard, Mikkel

    2015-06-01

    By whole-body MRI (WBMRI), we aimed to examine the frequency and distribution of inflammatory and structural lesions in PsA patients, SpA patients and healthy subjects (HSs), to introduce global WBMRI inflammation/damage scores, and to assess WBMRI's reproducibility and correlation with conventional MRI (convMRI). WBMRI (3.0-T) of patients with peripheral PsA (n = 18) or axial SpA (n = 18) and of HS (n = 12) was examined for proportion of evaluable features (readability) and the presence and pattern of lesions in axial and peripheral joints. Furthermore, global WBMRI scores of inflammation and structural damage were constructed, and WBMRI findings were compared with clinical measures and convMRI (SpA/HS: spine and SI joints; PsA/HS: hand). The readability (92-100%) and reproducibility (intrareader intraclass correlation coefficient: 0.62-1.0) were high in spine/SI joint, but lower in the distal peripheral joints. Wrists, shoulders, knees, ankles and MTP joints were most commonly involved, with frequency of synovitis > bone marrow oedema (BMO) > erosion. WBMRI global BMO scores of peripheral and axial joints were higher in PsA {median 7 [interquartile range (IQR) 3-15]} and SpA [8 (IQR 2-14)] than in HSs [2.5 (IQR 1-4.5)], both P joint scores were ρ = 0.20-0.78. WBMRI allows simultaneous assessment of peripheral and axial joints in PsA and SpA, and the distribution of inflammatory and structural lesions and global scores can be determined. The study strongly encourages further development and longitudinal testing of WBMRI techniques and assessment methods in PsA and SpA. © The Author 2014. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  2. Rapid P300 brain-computer interface communication with a head-mounted display

    Directory of Open Access Journals (Sweden)

    Ivo eKäthner

    2015-06-01

    Full Text Available Visual ERP (P300 based brain-computer interfaces (BCIs allow for fast and reliable spelling and are intended as a muscle-independent communication channel for people with severe paralysis. However, they require the presentation of visual stimuli in the field of view of the user. A head mounted display could allow convenient presentation of visual stimuli in situations, where mounting a conventional monitor might be difficult or not feasible (e.g. at a patient’s bedside. To explore if similar accuracies can be achieved with a virtual reality (VR headset compared to a conventional flat screen monitor, we conducted an experiment with 18 healthy participants. We also evaluated it with a person in the locked-in state (LIS to verify that usage of the headset is possible for a severely paralyzed person. Healthy participants performed online spelling with three different display methods. In one condition a 5x5 letter matrix was presented on a conventional 22 inch TFT monitor. Two configurations of the VR headset were tested. In the first (glasses A, the same 5x5 matrix filled the field of view of the user. In the second (glasses B, single letters of the matrix filled the field of view of the user. The participant in the LIS tested the VR headset on 3 different occasions (glasses A condition only. For healthy participants, average online spelling accuracies were 94% (15.5 bits/min using three flash sequences for spelling with the monitor and glasses A and 96% (16.2 bits/min with glasses B. In one session, the participant in the LIS reached an online spelling accuracy of 100% (10 bits/min using the glasses A condition. We also demonstrated that spelling with one flash sequence is possible with the VR headset for healthy users (mean: 32.1 bits/min, maximum reached by one user: 71.89 bits/min at 100% accuracy. We conclude that the VR headset allows for rapid P300 BCI communication in healthy users and may be a suitable display option for severely

  3. Rapid Response: To Scan or Not to Scan? The Utility of Noncontrast CT Head for Altered Mental Status.

    Science.gov (United States)

    Thacker, Purujit J; Sethi, Mansha; Sternlieb, Jonathan; Schneider, Doron; Naglak, Mary; Patel, Rajeshkumar R

    2018-01-17

    The aims of the study were the following: (1) to determine how often computed tomography (CT) scans of the head are obtained on rapid responses called for altered mental status (AMS), (2) to determine whether CT imaging of the head is required during all rapid responses called for AMS, (3) to determine which patients would benefit from CT scans of the head in this setting, (4) to note whether an adequate neurologic exam was documented, (5) to determine the cost of CT scans that did not change management, and (6) to examine the role of medications leading to AMS. The study was a retrospective chart review at Abington Jefferson Hospital. Data collected included the age, sex, time of rapid response, clinical condition of the patient, whether an arterial blood gas and blood glucose were done, and whether a neurological exam was documented in the resident's rapid response team note. The patient's medications were also reviewed. Computed tomography scan findings as well as changes made in a patient's care as a result of the scan were recorded. Any findings that did not lead to a change in management were considered a "negative" scan. Overall, 610 rapid responses were activated from January to August 2016. One hundred four (17.04%) of the total rapid responses were for AMS and 83 (79.8%) of these patients underwent noncontrast CT scan of the head. The mean (SD) age of the patients was 74.7 (13.6) years. A total of 56.6% were female. The most frequent clinical conditions documented at the time of rapid responses were noted as confused (33.7%, 28/83), either lethargic or unconscious (32.5%, 27/83), and concern for stroke (21.7%, 18/83). A total of 96.4% (80/83) of the CT scans done were negative for any acute changes. The three patients with positive scans (3/83) had a change in management as a result of the scans. If patients with symptoms concerning for stroke and unconscious patients are excluded, the total number of remaining patients is 56. Of these, zero patients had

  4. The HEADS-ED: a rapid mental health screening tool for pediatric patients in the emergency department.

    Science.gov (United States)

    Cappelli, Mario; Gray, Clare; Zemek, Roger; Cloutier, Paula; Kennedy, Allison; Glennie, Elizabeth; Doucet, Guy; Lyons, John S

    2012-08-01

    The American Academy of Pediatrics called for action for improved screening of mental health issues in the emergency department (ED). We developed the rapid screening tool home, education, activities/peers, drugs/alcohol, suicidality, emotions/behavior, discharge resources (HEADS-ED), which is a modification of "HEADS," a mnemonic widely used to obtain a psychosocial history in adolescents. The reliability and validity of the tool and its potential for use as a screening measure are presented. ED patients presenting with mental health concerns from March 1 to May 30, 2011 were included. Crisis intervention workers completed the HEADS-ED and the Child and Adolescent Needs and Strengths-Mental Health tool (CANS MH) and patients completed the Children's Depression Inventory (CDI). Interrater reliability was assessed by using a second HEADS-ED rater for 20% of the sample. A total of 313 patients were included, mean age was 14.3 (SD 2.63), and there were 182 females (58.1%). Interrater reliability was 0.785 (P mental health concerns.

  5. Effect of CT contrast on volumetric arc therapy planning (RapidArc and helical tomotherapy) for head and neck cancer

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Alan J.; Vora, Nayana [Department of Radiation Oncology, City of Hope National Medical Center, Duarte, CA (United States); Suh, Steve [Department of Radiation Physics, City of Hope National Medical Center, Duarte, CA (United States); Liu, An, E-mail: aliu@coh.org [Department of Radiation Physics, City of Hope National Medical Center, Duarte, CA (United States); Schultheiss, Timothy E. [Department of Radiation Physics, City of Hope National Medical Center, Duarte, CA (United States); Wong, Jeffrey Y.C. [Department of Radiation Oncology, City of Hope National Medical Center, Duarte, CA (United States)

    2015-04-01

    The objectives of the study were to evaluate the effect of intravenous contrast in the dosimetry of helical tomotherapy and RapidArc treatment for head and neck cancer and determine if it is acceptable during the computed tomography (CT) simulation to acquire only CT with contrast for treatment planning of head and neck cancer. Overall, 5 patients with head and neck cancer (4 men and 1 woman) treated on helical tomotherapy were analyzed retrospectively. For each patient, 2 consecutive CT scans were performed. The first CT set was scanned before the contrast injection and secondary study set was scanned 45 seconds after contrast. The 2 CTs were autoregistered using the same Digital Imaging and Communications in Medicine coordinates. Tomotherapy and RapidArc plans were generated on 1 CT data set and subsequently copied to the second CT set. Dose calculation was performed, and dose difference was analyzed to evaluate the influence of intravenous contrast media. The dose matrix used for comparison included mean, minimum and maximum doses of planning target volume (PTV), PTV dose coverage, and V{sub 45} {sub Gy}, V{sub 30} {sub Gy}, and V{sub 20} {sub Gy} organ doses. Treatment planning on contrasted images generally showed a lower dose to both organs and target than plans on noncontrasted images. The doses for the points of interest placed in the organs and target rarely changed more than 2% in any patient. In conclusion, treatment planning using a contrasted image had insignificant effect on the dose to the organs and targets. In our opinion, only CT with contrast needs to be acquired during the CT simulation for head and neck cancer. Dose calculations performed on contrasted images can potentially underestimate the delivery dose slightly. However, the errors of planning on a contrasted image should not affect the result in clinically significant way.

  6. Head-up tilt rapidly compromises hemodynamics in healthy anesthetized swine.

    Science.gov (United States)

    Mlcek, M; Belohlavek, J; Huptych, M; Boucek, T; Belza, T; Lacko, S; Krupickova, P; Hrachovina, M; Popkova, M; Neuzil, P; Kittnar, O

    2015-01-01

    The aims were to explore the effect of head-up tilt (HUT) to 30 and 60 degrees on hemodynamics and tissue oxygenation in anesthetized healthy swine. The data serve as a reference for a study of resuscitation efficacy at HUT such as during transport. Nine healthy swine (49+/-4 kg) were anesthetized and multiple sensors including myocardial pressure-volume loops catheter, carotid flow probe, blood pressure catheters, near infrared spectroscopy (NIRS) tissue oximetry and mixed venous oximetry (SVO2) catheter were introduced and parameters continuously recorded. Experimental protocol consisted of baseline in supine position (15 min), 30 degrees HUT (15 min), recovery at supine position (15 min) and 60 degrees HUT (5 min). Vacuum mattress was used for body fixation during tilts. We found that 30 and 60 degrees inclination led to significant immediate reduction in hemodynamic and oximetry parameters. Mean arterial pressure (mm Hg) decreased from 98 at baseline to 53 and 39, respectively. Carotid blood flow dropped to 47 % and 22 % of baseline values, end diastolic volume to 49 % and 53 % and stroke volume to 47 % and 45 % of baseline. SVO2 and tissue oximetry decreased by 17 and 21 percentage points. The values are means. In conclusions, within minutes, both 30 and 60 degrees head-up tilting is poorly tolerated in anesthetized swine. Significant differences among individual animals exist.

  7. Mechanical study in vitro of the resistance of axial forces of 3.5 mm cannulated and conventional screws in head and femoral neck fractures

    OpenAIRE

    Ferrigno, Cassio Ricardo Auada; Baccarin,Daniel Castelo Branco; Pereira, César Augusto Martins; Ferreira, Márcio Poletto

    2014-01-01

    Background: Proximal femoral fractures account for 25% of all femoral fractures in dogs and are more common in young animals. Osteosynthesis of femoral head and neck fractures is a complex procedure that can be performed using conventional screws or wires. However, proper fracture reduction and fi xation are diffi cult to achieve and, despite many advancements, such fractures remain challenging to solve. Cannulated screws have good compressive capacity and can be employed to simplify the surg...

  8. Acute effects of Radiotherapy in patients with Head and Neck Cancer: IMRT vs RapidArcTM

    Directory of Open Access Journals (Sweden)

    Liliana Silva

    2013-12-01

    Full Text Available Radiation therapy is a standard treatment in the multidisciplinary approach to the treatment of head and neck carcinomas (HNC. The description and perception of the effects caused by the treatment in the normal tissues is important for the clinical evaluation of the patient because treatment is interrupted if the patient develops several acute side effects which directly affect their survival. This study involved 46 patients over 6 weeks of treatment and evaluated the observed acute effects of treatment in five different anatomical areas - skin, mucosa, salivary glands, pharynx /esophagus and larynx. This evaluation adopted the classification of the Acute Radiation Morbidity Scoring Criteria of the Radiation Therapy Oncology Group (RTOG. Data analysis revealed that the acute effects related to the RapidArcTM technique appeared earlier when compared to IMRT techniques. On the other hand, the IMRT technique showed more exacerbated high-grade effects.

  9. Analysis of late complications after rapid hyperfractionated radiotherapy in advanced head and neck cancers

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, T.D.; Panis, X.; Froissart, D.; Legros, M.; Coninx, P.; Loirette, M.

    1988-01-01

    Late effects were analyzed in a series of 39 patients with a 2-year minimal follow-up who were treated by rapid hyperfractionated radiotherapy. The total dose was 66-72 Gy delivered in two series of 33-36 Gy separated by a 2-4 week rest interval. The number of daily fractions ranged from 8 to 6 and the interval between each fraction was 2 hr. Late complications consisted of cervical fibrosis, mucosal necrosis, bone necrosis, trismus, and laryngeal edema. Seventy percent of patients experienced late complications, and in 54% of cases, these reactions were considered severe, causing death in 13% of patients. No relationship was found between field sizes, dosimetric data and type and frequency of late effects. It is therefore suggested that the interval between two daily sessions in any multifractionated protocol may be of critical importance.

  10. Design of a head phantom produced on a 3D rapid prototyping printer and comparison with a RANDO and 3M lucite head phantom in eye dosimetry applications

    Science.gov (United States)

    Homolka, Peter; Figl, Michael; Wartak, Andreas; Glanzer, Mathias; Dünkelmeyer, Martina; Hojreh, Azadeh; Hummel, Johann

    2017-04-01

    An anthropomorphic head phantom including eye inserts allowing placement of TLDs 3 mm below the cornea has been produced on a 3D printer using a photo-cured acrylic resin to best allow tissue equivalence. Thus Hp(3) can be determined in radiological and interventional photon radiation fields. Eye doses and doses to the forehead have been compared to an Alderson RANDO head and a 3M Lucite skull phantom in terms of surface dose per incident air kerma for frontal irradiation since the commercial phantoms do not allow placement of TLDs 3 mm below the corneal surface. A comparison of dose reduction factors (DRFs) of a common lead glasses model has also been performed. Eye dose per incident air kerma were comparable between all three phantoms (printed phantom: 1.40, standard error (SE) 0.04; RANDO: 1.36, SE 0.03; 3M: 1.37, SE 0.03). Doses to the forehead were identical to eye surface doses for the printed phantom and the RANDO head (ratio 1.00 SE 0.04, and 0.99 SE 0.03, respectively). In the 3M Lucite skull phantom dose on the forehead was 15% lower than dose to the eyes attributable to phantom properties. DRF of a sport frame style leaded glasses model with 0.75 mm lead equivalence measured were 6.8 SE 0.5, 9.3 SE 0.4 and 10.5 SE 0.5 for the RANDO head, the printed phantom, and the 3M Lucite head phantom, respectively, for frontal irradiation. A comparison of doses measured in 3 mm depth and on the surface of the eyes in the printed phantom revealed no difference larger than standard errors from TLD dosimetry. 3D printing offers an interesting opportunity for phantom design with increasing potential as printers allowing combinations of tissue substitutes will become available. Variations between phantoms may provide a useful indication of uncertainty budgets when using phantom measurements to estimate individual personnel doses.

  11. Design of a head phantom produced on a 3D rapid prototyping printer and comparison with a RANDO and 3M lucite head phantom in eye dosimetry applications.

    Science.gov (United States)

    Homolka, Peter; Figl, Michael; Wartak, Andreas; Glanzer, Mathias; Dünkelmeyer, Martina; Hojreh, Azadeh; Hummel, Johann

    2017-04-21

    An anthropomorphic head phantom including eye inserts allowing placement of TLDs 3 mm below the cornea has been produced on a 3D printer using a photo-cured acrylic resin to best allow tissue equivalence. Thus H p (3) can be determined in radiological and interventional photon radiation fields. Eye doses and doses to the forehead have been compared to an Alderson RANDO head and a 3M Lucite skull phantom in terms of surface dose per incident air kerma for frontal irradiation since the commercial phantoms do not allow placement of TLDs 3 mm below the corneal surface. A comparison of dose reduction factors (DRFs) of a common lead glasses model has also been performed. Eye dose per incident air kerma were comparable between all three phantoms (printed phantom: 1.40, standard error (SE) 0.04; RANDO: 1.36, SE 0.03; 3M: 1.37, SE 0.03). Doses to the forehead were identical to eye surface doses for the printed phantom and the RANDO head (ratio 1.00 SE 0.04, and 0.99 SE 0.03, respectively). In the 3M Lucite skull phantom dose on the forehead was 15% lower than dose to the eyes attributable to phantom properties. DRF of a sport frame style leaded glasses model with 0.75 mm lead equivalence measured were 6.8 SE 0.5, 9.3 SE 0.4 and 10.5 SE 0.5 for the RANDO head, the printed phantom, and the 3M Lucite head phantom, respectively, for frontal irradiation. A comparison of doses measured in 3 mm depth and on the surface of the eyes in the printed phantom revealed no difference larger than standard errors from TLD dosimetry. 3D printing offers an interesting opportunity for phantom design with increasing potential as printers allowing combinations of tissue substitutes will become available. Variations between phantoms may provide a useful indication of uncertainty budgets when using phantom measurements to estimate individual personnel doses.

  12. Fourier analysis of He 4471/Mg 4481 line profiles for separating rotational velocity and axial inclination in rapidly rotating B-type stars

    Science.gov (United States)

    Takeda, Y.; Kawanomoto, S.; Ohishi, N.

    2017-11-01

    While the effect of rotation on spectral lines is complicated in rapidly rotating stars because of the appreciable gravity-darkening effect differing from line to line, it is possible to make use of this line-dependent complexity to separately determine the equatorial rotation velocity (ve) and the inclination angle (I) of rotational axis. Although linewidths of spectral lines were traditionally used for this aim, we tried in this study to apply the Fourier method, which utilizes the unambiguously determinable first-zero frequency (σ1) in the Fourier transform of line profile. Equipped with this technique, we analysed the profiles of He I 4471 and Mg I 4481 lines of six rapidly rotating (ve sin I ˜ 150-300 km s-1) late B-type stars, while comparing them with the theoretical profiles simulated on a grid of models computed for various combination of (ve, I). According to our calculation, σ1 tends to be larger than the classical value for given ve sin I. This excess progressively grows with an increase in ve, and is larger for the He line than the Mg line, which leads to {σ} 1^He > {σ} 1^Mg. It was shown that ve and I are separately determinable from the intersection of two loci (sets of solutions reproducing the observed σ1 for each line) on the ve versus I plane. Yet, line profiles alone are not sufficient for their unique discrimination, for which photometric information (such as colours) needs to be simultaneously employed.

  13. A survey of a population of anaesthesiologists from South India regarding practices for rapid sequence intubation in patients with head injury

    Directory of Open Access Journals (Sweden)

    Satyen Parida

    2016-01-01

    Full Text Available Background and Aims: Evidence and utility of the individual steps of the rapid sequence induction and tracheal intubation protocols have been debated, especially in the setting of traumatic brain injury. The purpose of this survey was to determine preferences in the current approach to rapid sequence intubation ( RSI in head injury patients among a population of anaesthesiologists from South India. Methods: A questionnaire was E-mailed to all the members of the Indian Society of Anaesthesiologists′ South Zone Chapter to ascertain their preferences, experience and comfort level with regard to their use of rapid sequence intubation techniques in adult patients with head injury. Participants were requested to indicate their practices for RSI technique for a head-injured patient upon arrival at the Emergency Medical Services department of their hospital. Results: The total response rate was 56.9% (530/932. Of the total respondents, 35% of the clinicians used cricoid pressure routinely, most respondents (68% stated that they pre-oxygenate the patients for about 3 min prior to RSI, thiopentone (61% and propofol (34% were commonly used prior to intubation. Rocuronium was the muscle relaxant of choice for RSI among the majority (44%, compared to succinylcholine (39%. Statistical analyses were performed after the initial entry onto a spreadsheet. Data were summarised descriptively using frequency distribution. Conclusion: In a rapid sequence intubation situation, the practice differed significantly among anaesthesiologists. Owing to disagreements and paucity of evidence-based data regarding the standards of RSI, it is apparent that RSI practice still has considerable variability in clinical practice.

  14. Photogrammetry-Based Head Digitization for Rapid and Accurate Localization of EEG Electrodes and MEG Fiducial Markers Using a Single Digital SLR Camera.

    Science.gov (United States)

    Clausner, Tommy; Dalal, Sarang S; Crespo-García, Maité

    2017-01-01

    The performance of EEG source reconstruction has benefited from the increasing use of advanced head modeling techniques that take advantage of MRI together with the precise positions of the recording electrodes. The prevailing technique for registering EEG electrode coordinates involves electromagnetic digitization. However, the procedure adds several minutes to experiment preparation and typical digitizers may not be accurate enough for optimal source reconstruction performance (Dalal et al., 2014). Here, we present a rapid, accurate, and cost-effective alternative method to register EEG electrode positions, using a single digital SLR camera, photogrammetry software, and computer vision techniques implemented in our open-source toolbox, janus3D. Our approach uses photogrammetry to construct 3D models from multiple photographs of the participant's head wearing the EEG electrode cap. Electrodes are detected automatically or semi-automatically using a template. The rigid facial features from these photo-based models are then surface-matched to MRI-based head reconstructions to facilitate coregistration to MRI space. This method yields a final electrode coregistration error of 0.8 mm, while a standard technique using an electromagnetic digitizer yielded an error of 6.1 mm. The technique furthermore reduces preparation time, and could be extended to a multi-camera array, which would make the procedure virtually instantaneous. In addition to EEG, the technique could likewise capture the position of the fiducial markers used in magnetoencephalography systems to register head position.

  15. Rapid on-site evaluation with dynamic telecytopathology for ultrasound-guided fine-needle aspiration of head and neck nonthyroid lesions

    Directory of Open Access Journals (Sweden)

    Kamal K Khurana

    2015-01-01

    Full Text Available Background: Rapid on-site evaluation (ROSE at the time of ultrasound-guided fine-needle aspiration (USGFNA of head and neck lesion is essential for obtaining adequate samples and providing the preliminary diagnosis. We summarize our experience with ROSE of USGFNA on head and neck nonthyroid lesions using telecytopathology. Materials and Methods: Real-time images of Diff-Quik stained cytology smears were obtained at ultrasound suite with an Olympus DP-70 digital camera attached to an Olympus CX41 microscope, and transmitted via ethernet by a cytotechnologist to a cytopathologist in cytopathology laboratory who rendered a preliminary diagnosis. Live communication was conducted with Vocera voice communication system. The ultrasound suite was located on different floor from the cytopathology laboratory. Accuracy of ROSE via telecytopathology was compared with an equal number of cases that received ROSE, prior to introduction of telecytopathology, via conventional microscopy. Results: Rapid on-site evaluation was performed on a total of 116 USGFNA of head and neck nonthyroid lesions. The telecytopathology system and conventional microscopy was used to evaluate equal number of cases (58 each. Preliminary diagnoses of benign, atypical/suspicious for malignancy, and positive for malignancy were 72.4%, 17.2% and 10.3% for telecytopathology, and 69.0%, 10.3% and 20.7% for conventional microscopy. None of the cases were deemed unsatisfactory. The overall concordance between the preliminary and final diagnoses was 94.8% for telecytopathology and 98.3% for conventional microscopy and was not statistically significant (P = 0.309. The causes of discordant preliminary and final diagnoses were mainly attributed to availability of cell block and Papanicolaou-stained slides for review or flow cytometry results for lymphoma cases at the time of final sign out. Conclusions: Telecytopathology is comparable with conventional microscopy in ROSE of USGFNA of head and

  16. Comparative study between IMRT planning and RapidArc® sliding window for head and neck tumors; Estudo comparativo de planejamento entre IMRT sliding window e RapidArc® para tumores de cabeca e pescoco

    Energy Technology Data Exchange (ETDEWEB)

    Pirani, Luiz F.; Silva, Leonardo P.; Lima, Marilia B.; Bittencourt, Guilherme R.; Ferreira, Anne Caroline M.; Batista, Delano V.S., E-mail: nando_lfp@yahoo.com.br [Instituto Nacional de Cancer (INCA), Rio de Janeiro, RJ (Brazil)

    2012-12-15

    This study aims to evaluate the RapidArc (RA) technique in the treatment of head and neck tumors and compare the results of treatments with intensity modulated radiation therapy (IMRT) in the National Cancer Institute (INCA). Head and neck carcinomas have a natural history with relative expansion to others regions, especially in advanced levels. Faster treatments, with better coverage of the Planning Target Volume (PTV) and sparing more risks organs (ROs) are necessary and bring a better clinical impact. Ten patients with head and neck cancer, planned with IMRT technique were replanned using the RA technique. Some dosimetric indexes were calculated for both techniques, with the intention of verifying which of them, at the same time, would promote greater coverage of the PTV and preserve more healthy tissue. In terms of coverage, both indexes were similar. The RA technique was more efficient for delivered doses to ROs. The number of monitor units (MU), number of fields and treatments time estimated were lower than IMRT technique. Finally, the results have showed that the RA technique clearly reduces the treatment time, reducing the average and maximum dose to ROs and conforming the target as IMRT technique. (author)

  17. Axial Rod Coupling Design

    National Research Council Canada - National Science Library

    Smith, David R

    2003-01-01

    .... The axial rod and coupling has been designed to withstand external survival loads ( 8.3 kN (1,870 lb) for Ring 5), and to maintain its length to within 7 microns after disassembly and reassembly...

  18. Axial static mixer

    Science.gov (United States)

    Sandrock, H.E.

    1982-05-06

    Static axial mixing apparatus includes a plurality of channels, forming flow paths of different dimensions. The axial mixer includes a flow adjusting device for adjustable selective control of flow resistance of various flow paths in order to provide substantially identical flows through the various channels, thereby reducing nonuniform coating of interior surfaces of the channels. The flow adjusting device may include diaphragm valves, and may further include a pressure regulating system therefor.

  19. 3D Rapid Prototyping for Otolaryngology—Head and Neck Surgery: Applications in Image-Guidance, Surgical Simulation and Patient-Specific Modeling

    Science.gov (United States)

    Chan, Harley H. L.; Siewerdsen, Jeffrey H.; Vescan, Allan; Daly, Michael J.; Prisman, Eitan; Irish, Jonathan C.

    2015-01-01

    The aim of this study was to demonstrate the role of advanced fabrication technology across a broad spectrum of head and neck surgical procedures, including applications in endoscopic sinus surgery, skull base surgery, and maxillofacial reconstruction. The initial case studies demonstrated three applications of rapid prototyping technology are in head and neck surgery: i) a mono-material paranasal sinus phantom for endoscopy training ii) a multi-material skull base simulator and iii) 3D patient-specific mandible templates. Digital processing of these phantoms is based on real patient or cadaveric 3D images such as CT or MRI data. Three endoscopic sinus surgeons examined the realism of the endoscopist training phantom. One experienced endoscopic skull base surgeon conducted advanced sinus procedures on the high-fidelity multi-material skull base simulator. Ten patients participated in a prospective clinical study examining patient-specific modeling for mandibular reconstructive surgery. Qualitative feedback to assess the realism of the endoscopy training phantom and high-fidelity multi-material phantom was acquired. Conformance comparisons using assessments from the blinded reconstructive surgeons measured the geometric performance between intra-operative and pre-operative reconstruction mandible plates. Both the endoscopy training phantom and the high-fidelity multi-material phantom received positive feedback on the realistic structure of the phantom models. Results suggested further improvement on the soft tissue structure of the phantom models is necessary. In the patient-specific mandible template study, the pre-operative plates were judged by two blinded surgeons as providing optimal conformance in 7 out of 10 cases. No statistical differences were found in plate fabrication time and conformance, with pre-operative plating providing the advantage of reducing time spent in the operation room. The applicability of common model design and fabrication techniques

  20. 3D Rapid Prototyping for Otolaryngology-Head and Neck Surgery: Applications in Image-Guidance, Surgical Simulation and Patient-Specific Modeling.

    Directory of Open Access Journals (Sweden)

    Harley H L Chan

    Full Text Available The aim of this study was to demonstrate the role of advanced fabrication technology across a broad spectrum of head and neck surgical procedures, including applications in endoscopic sinus surgery, skull base surgery, and maxillofacial reconstruction. The initial case studies demonstrated three applications of rapid prototyping technology are in head and neck surgery: i a mono-material paranasal sinus phantom for endoscopy training ii a multi-material skull base simulator and iii 3D patient-specific mandible templates. Digital processing of these phantoms is based on real patient or cadaveric 3D images such as CT or MRI data. Three endoscopic sinus surgeons examined the realism of the endoscopist training phantom. One experienced endoscopic skull base surgeon conducted advanced sinus procedures on the high-fidelity multi-material skull base simulator. Ten patients participated in a prospective clinical study examining patient-specific modeling for mandibular reconstructive surgery. Qualitative feedback to assess the realism of the endoscopy training phantom and high-fidelity multi-material phantom was acquired. Conformance comparisons using assessments from the blinded reconstructive surgeons measured the geometric performance between intra-operative and pre-operative reconstruction mandible plates. Both the endoscopy training phantom and the high-fidelity multi-material phantom received positive feedback on the realistic structure of the phantom models. Results suggested further improvement on the soft tissue structure of the phantom models is necessary. In the patient-specific mandible template study, the pre-operative plates were judged by two blinded surgeons as providing optimal conformance in 7 out of 10 cases. No statistical differences were found in plate fabrication time and conformance, with pre-operative plating providing the advantage of reducing time spent in the operation room. The applicability of common model design and

  1. 3D Rapid Prototyping for Otolaryngology-Head and Neck Surgery: Applications in Image-Guidance, Surgical Simulation and Patient-Specific Modeling.

    Science.gov (United States)

    Chan, Harley H L; Siewerdsen, Jeffrey H; Vescan, Allan; Daly, Michael J; Prisman, Eitan; Irish, Jonathan C

    2015-01-01

    The aim of this study was to demonstrate the role of advanced fabrication technology across a broad spectrum of head and neck surgical procedures, including applications in endoscopic sinus surgery, skull base surgery, and maxillofacial reconstruction. The initial case studies demonstrated three applications of rapid prototyping technology are in head and neck surgery: i) a mono-material paranasal sinus phantom for endoscopy training ii) a multi-material skull base simulator and iii) 3D patient-specific mandible templates. Digital processing of these phantoms is based on real patient or cadaveric 3D images such as CT or MRI data. Three endoscopic sinus surgeons examined the realism of the endoscopist training phantom. One experienced endoscopic skull base surgeon conducted advanced sinus procedures on the high-fidelity multi-material skull base simulator. Ten patients participated in a prospective clinical study examining patient-specific modeling for mandibular reconstructive surgery. Qualitative feedback to assess the realism of the endoscopy training phantom and high-fidelity multi-material phantom was acquired. Conformance comparisons using assessments from the blinded reconstructive surgeons measured the geometric performance between intra-operative and pre-operative reconstruction mandible plates. Both the endoscopy training phantom and the high-fidelity multi-material phantom received positive feedback on the realistic structure of the phantom models. Results suggested further improvement on the soft tissue structure of the phantom models is necessary. In the patient-specific mandible template study, the pre-operative plates were judged by two blinded surgeons as providing optimal conformance in 7 out of 10 cases. No statistical differences were found in plate fabrication time and conformance, with pre-operative plating providing the advantage of reducing time spent in the operation room. The applicability of common model design and fabrication techniques

  2. A comparative study of standard intensity-modulated radiotherapy and RapidArc planning techniques for ipsilateral and bilateral head and neck irradiation.

    Science.gov (United States)

    Pursley, Jennifer; Damato, Antonio L; Czerminska, Maria A; Margalit, Danielle N; Sher, David J; Tishler, Roy B

    2017-01-01

    The purpose of this study was to investigate class solutions using RapidArc volumetric-modulated arc therapy (VMAT) planning for ipsilateral and bilateral head and neck (H&N) irradiation, and to compare dosimetric results with intensity-modulated radiotherapy (IMRT) plans. A total of 14 patients who received ipsilateral and 10 patients who received bilateral head and neck irradiation were retrospectively replanned with several volumetric-modulated arc therapy techniques. For ipsilateral neck irradiation, the volumetric-modulated arc therapy techniques included two 360° arcs, two 360° arcs with avoidance sectors around the contralateral parotid, two 260° or 270° arcs, and two 210° arcs. For bilateral neck irradiation, the volumetric-modulated arc therapy techniques included two 360° arcs, two 360° arcs with avoidance sectors around the shoulders, and 3 arcs. All patients had a sliding-window-delivery intensity-modulated radiotherapy plan that was used as the benchmark for dosimetric comparison. For ipsilateral neck irradiation, a volumetric-modulated arc therapy technique using two 360° arcs with avoidance sectors around the contralateral parotid was dosimetrically comparable to intensity-modulated radiotherapy, with improved conformity (conformity index = 1.22 vs 1.36, p irradiation, 3-arc volumetric-modulated arc therapy techniques were dosimetrically comparable to intensity-modulated radiotherapy while also avoiding irradiation through the shoulders. All volumetric-modulated arc therapy techniques required fewer monitor units than sliding-window intensity-modulated radiotherapy to deliver treatment, with an average reduction of 35% for ipsilateral plans and 67% for bilateral plans. Thus, for ipsilateral head and neck irradiation a volumetric-modulated arc therapy technique using two 360° arcs with avoidance sectors around the contralateral parotid is recommended. For bilateral neck irradiation, 2- or 3-arc techniques are dosimetrically comparable to

  3. Unilateral and bilateral neck SIB for head and neck cancer patients. Intensity-modulated proton therapy, tomotherapy, and RapidArc

    Energy Technology Data Exchange (ETDEWEB)

    Stromberger, Carmen; Budach, Volker; Ghadjar, Pirus; Wlodarczyk, Waldemar; Marnitz, Simone [Charite - Universitaetsmedizin Berlin, Department of Radiation Oncology and Radiotherapy, Berlin (Germany); Cozzi, Luca; Fogliata, Antonella [Humanitas Cancer Center Milan, Radiotherapy and Radiosurgery Department, Milan (Italy); Jamil, Basil [Klinikum Frankfurt Oder, Praxis fuer Strahlentherapie, Frankfurt Oder (Germany); Raguse, Jan D. [Clinic for Oral and Maxillofacial Surgery, Berlin (Germany); Boettcher, Arne [Charite - Universitaetsmedizin Berlin, Department of Otorhinolaryngology, Berlin (Germany)

    2016-04-15

    To compare simultaneous integrated boost plans for intensity-modulated proton therapy (IMPT), helical tomotherapy (HT), and RapidArc therapy (RA) for patients with head and neck cancer. A total of 20 patients with squamous cell carcinoma of the head and neck received definitive chemoradiation with bilateral (n = 14) or unilateral (n = 6) neck irradiation and were planned using IMPT, HT, and RA with 54.4, 60.8, and 70.4 GyE/Gy in 32 fractions. Dose distributions, coverage, conformity, homogeneity to planning target volumes (PTV)s and sparing of organs at risk and normal tissue were compared. All unilateral and bilateral plans showed excellent PTV coverage and acceptable dose conformity. For unilateral treatment, IMPT delivered substantially lower mean doses to contralateral salivary glands (< 0.001-1.1 Gy) than both rotational techniques did (parotid gland: 6-10 Gy; submandibular gland: 15-20 Gy). Regarding the sparing of classical organs at risk for bilateral treatment, IMPT and HT were similarly excellent and RA was satisfactory. For unilateral neck irradiation, IMPT may minimize the dry mouth risk in this subgroup but showed no advantage over HT for bilateral neck treatment regarding classical organ-at-risk sparing. All methods satisfied modern standards regarding toxicity and excellent target coverage for unilateral and bilateral treatment of head and neck cancer at the planning level. (orig.) [German] Planvergleich von intensitaetsmodulierter Protonentherapie (IMPT), Tomotherapie (HT) und RapidArc-Therapie (RA) fuer Patienten mit Plattenepithelkarzinomen der Kopf-Hals-Region unter Anwendung des simultan integrierten Boost-Konzepts (SIB). Fuer 20 Patienten mit Plattenepithelkarzinomen der Kopf-Hals-Region und bilateraler (n = 14) oder unilateraler (n = 6) zervikaler primaerer Radiochemotherapie erfolgte eine IMPT-, HT- und RA-Planung mit 54,4, 60,8 und 70,4 GyE/Gy in 32 Fraktionen. Die Dosisverteilung, Abdeckung, Konformitaet und Homogenitaet der PTVs sowie die

  4. Axial Extension (Posture Exercise)

    Science.gov (United States)

    ... this helps: It lengthens your spine, which improves posture, and increases comfort, mobility and range of motion. Many of us have a forward head posture. We get this from the type of recreation ...

  5. Computerised Axial Tomography (CAT)

    Science.gov (United States)

    1990-06-01

    Tumoral pathology Tumoral pathology provides one of the most valid applications of computerised axial tomography. With this technique, it is possible to... retroperitoneal cavity, while, in the pulmonary field, the results obtained are less decisive. Let us analyse, briefly, the research carried out with CT...the abscesses, are generally of lesser density with respect to the integral parenchyma; also, with abscesses the limits of the tumoral mass are less

  6. Cervical Spine Axial Rotation Goniometer Design

    Directory of Open Access Journals (Sweden)

    Emin Ulaş Erdem

    2012-06-01

    Full Text Available To evaluate the cervical spine rotation movement is quiet harder than other joints. Configuration and arrangement of current goniometers and devices is not always practic in clinics and some methods are quiet expensive. The cervical axial rotation goniometer designed by the authors is consists of five pieces (head apparatus, chair, goniometric platform, eye pads and camera. With this goniometer design a detailed evaluation of cervical spine range of motion can be obtained. Besides, measurement of "joint position sense" which is recently has rising interest in researches can be made practically with this goniometer.

  7. Astrocyte Structural and Molecular Response to Elevated Intraocular Pressure Occurs Rapidly and Precedes Axonal Tubulin Rearrangement within the Optic Nerve Head in a Rat Model.

    Directory of Open Access Journals (Sweden)

    Shandiz Tehrani

    Full Text Available Glaucomatous axon injury occurs at the level of the optic nerve head (ONH in response to uncontrolled intraocular pressure (IOP. The temporal response of ONH astrocytes (glial cells responsible for axonal support to elevated IOP remains unknown. Here, we evaluate the response of actin-based astrocyte extensions and integrin-based signaling within the ONH to 8 hours of IOP elevation in a rat model. IOP elevation of 60 mm Hg was achieved under isoflurane anesthesia using anterior chamber cannulation connected to a saline reservoir. ONH astrocytic extension orientation was significantly and regionally rearranged immediately after IOP elevation (inferior ONH, 43.2° ± 13.3° with respect to the anterior-posterior axis versus 84.1° ± 1.3° in controls, p<0.05, and re-orientated back to baseline orientation 1 day post IOP normalization. ONH axonal microtubule filament label intensity was significantly reduced 1 and 3 days post IOP normalization, and returned to control levels on day 5. Phosphorylated focal adhesion kinase (FAK levels steadily decreased after IOP normalization, while levels of phosphorylated paxillin (a downstream target of FAK involved in focal adhesion dynamics were significantly elevated 5 days post IOP normalization. The levels of phosphorylated cortactin (a downstream target of Src kinase involved in actin polymerization were significantly elevated 1 and 3 days post IOP normalization and returned to control levels by day 5. No significant axon degeneration was noted by morphologic assessment up to 5 days post IOP normalization. Actin-based astrocyte structure and signaling within the ONH are significantly altered within hours after IOP elevation and prior to axonal cytoskeletal rearrangement, producing some responses that recover rapidly and others that persist for days despite IOP normalization.

  8. Clinical and dosimetric evaluation of RapidArc versus standard sliding window IMRT in the treatment of head and neck cancer

    Energy Technology Data Exchange (ETDEWEB)

    Smet, Stephanie; Lambrecht, Maarten; Vanstraelen, Bianca; Nuyts, Sandra [University Hospitals Leuven, Department of Radiation Oncology, Leuven (Belgium)

    2014-08-29

    Several planning studies have already proven the substantial dosimetric advantages of RapidArc (RA) over standard intensity-modulated radiotherapy. We retrospectively compared RapidArc and standard sliding window IMRT (swIMRT) in locally advanced head and neck cancer, looking both at dosimetrics as well as toxicity and outcome. CT datasets of 78 patients treated with swIMRT and 79 patients treated with RA were included. To compare the resulting dose distributions, the dose-volume parameters were evaluated for the planning target volumes (PTVs), clinical target volumes (CTVs), and organs at risk (OARs), and the number of MU were calculated. Acute toxicity was assessed by the Common Toxicity Criteria version 3.0. PTV coverage with the 95 % isodose was slightly better for RA. Dose distribution has proven to be significantly more homogenous with RA and led to a reduction of 62 % in MU with better OAR sparing. As for toxicity, more grade 3 mucositis and dysphagia was observed for swIMRT, though we observed more grade 3 dermatitis for RA. In our retrospective analysis, RA had better target coverage and better sparing of the OAR. Overall, the grade of acute toxicity was lower for RA than for swIMRT for the same types of tumor locations, except for the grade of dermatitis. (orig.) [German] Mehrere Studien haben die dosimetrische Ueberlegenheit der RapidArc (RA) gegenueber der intensitaetsmodulierten Standard-Radiotherapie (IMRT) bereits gezeigt. In unserer Studie verglichen wir retrospektiv die RapidArc und die dynamische (''standard sliding window'') IMRT (swIMRT) bei lokal fortgeschrittenen Kopf-Hals-Karzinomen sowohl hinsichtlich dosimetrischer Daten als auchEffektivitaet und Toxizitaet. Die CT-Datenanalysen von 78 Patienten, die mit swIMRT behandelt wurden, und von 79 Patienten, welche RA erhalten hatten, wurden in die Studie aufgenommen. Um die darauf resultierenden applizierten Dosen vergleichen zu koennen, wurden die Dosis-Volumen-Parameter fuer

  9. Critical Axial Load

    Directory of Open Access Journals (Sweden)

    Walt Wells

    2008-01-01

    Full Text Available Our objective in this paper is to solve a second order differential equation for a long, simply supported column member subjected to a lateral axial load using Heun's numerical method. We will use the solution to find the critical load at which the column member will fail due to buckling. We will calculate this load using Euler's derived analytical approach for an exact solution, as well as Euler's Numerical Method. We will then compare the three calculated values to see how much they deviate from one another. During the critical load calculation, it will be necessary to calculate the moment of inertia for the column member.

  10. 3D Rapid Prototyping for Otolaryngology-Head and Neck Surgery: Applications in Image-Guidance, Surgical Simulation and Patient-Specific Modeling

    National Research Council Canada - National Science Library

    Chan, Harley H L; Siewerdsen, Jeffrey H; Vescan, Allan; Daly, Michael J; Prisman, Eitan; Irish, Jonathan C

    2015-01-01

    The aim of this study was to demonstrate the role of advanced fabrication technology across a broad spectrum of head and neck surgical procedures, including applications in endoscopic sinus surgery...

  11. Dissipative Axial Inflation

    CERN Document Server

    Notari, Alessio

    2016-12-22

    We analyze in detail the background cosmological evolution of a scalar field coupled to a massless abelian gauge field through an axial term $\\frac{\\phi}{f_\\gamma} F \\tilde{F}$, such as in the case of an axion. Gauge fields in this case are known to experience tachyonic growth and therefore can backreact on the background as an effective dissipation into radiation energy density $\\rho_R$, which which can lead to inflation without the need of a flat potential. We analyze the system, for momenta $k$ smaller than the cutoff $f_\\gamma$, including numerically the backreaction. We consider the evolution from a given static initial condition and explicitly show that, if $f_\\gamma$ is smaller than the field excursion $\\phi_0$ by about a factor of at least ${\\cal O} (20)$, there is a friction effect which turns on before that the field can fall down and which can then lead to a very long stage of inflation with a generic potential. In addition we find superimposed oscillations, which would get imprinted on any kind of...

  12. The Design Method of Axial Flow Runners Focusing on Axial Flow Velocity Uniformization and Its Application to an Ultra-Small Axial Flow Hydraulic Turbine

    Directory of Open Access Journals (Sweden)

    Yasuyuki Nishi

    2016-01-01

    Full Text Available We proposed a portable and ultra-small axial flow hydraulic turbine that can generate electric power comparatively easily using the low head of open channels such as existing pipe conduits or small rivers. In addition, we proposed a simple design method for axial flow runners in combination with the conventional one-dimensional design method and the design method of axial flow velocity uniformization, with the support of three-dimensional flow analysis. Applying our design method to the runner of an ultra-small axial flow hydraulic turbine, the performance and internal flow of the designed runner were investigated using CFD analysis and experiment (performance test and PIV measurement. As a result, the runners designed with our design method were significantly improved in turbine efficiency compared to the original runner. Specifically, in the experiment, a new design of the runner achieved a turbine efficiency of 0.768. This reason was that the axial component of absolute velocity of the new design of the runner was relatively uniform at the runner outlet in comparison with that of the original runner, and as a result, the negative rotational flow was improved. Thus, the validity of our design method has been verified.

  13. Internal combustion engine with axial double pistons. Verbrennungsmotor mit axial angeordneten Doppelkolben

    Energy Technology Data Exchange (ETDEWEB)

    Albersinger, G.

    1980-07-24

    The invention refers to the configuration of an internal combustion engine with axial double pistons. It is characterized by the fact that these double pistons work in a cylinder block divided into a suction side and a combustion side, where a so-called swashplate acts as the power transmission part between the piston and the drive shaft. Special constructional characteristics of the cylinder block divided into two are that the suction half and the combustion half are connected by a crankcase, which accommodates the swashplate, and that automatic inlet valves are situated in the cylinder head of the suction half and outlet valves actuated by the drive shaft are situated in the cylinder head on the combustion side. This construction of engine according to the invention has a very high efficiency. Further, there is a very favourable effect on the generation of exhaust gas and low value fuels can be used.

  14. Parkinsonian axial signs in schizophrenia.

    Science.gov (United States)

    Morgante, Francesca; Barbui, Corrado; Tinazzi, Michele

    2017-03-01

    We have recently demonstrated evidence of nigro-striatal denervation, disease progression and response to levodopa in a subgroup of patients with schizophrenia who developed parkinsonism. In the present study, we investigated whether axial parkinsonian signs might be an early manifestation of parkinsonism in schizophrenia not necessarily related to chronic administration of antipsychotic drugs (AP) drugs. From a baseline cohort of 299 schizophrenic patients who did not satisfy the diagnostic criteria for parkinsonism (presence of at least two of the following appendicular signs: bradykinesia, tremor, rigidity), we identified a group of patients who manifested two out of three axial parkinsonian signs (abnormality of trunk posture, hypomimia and short-step gait). Accordingly, we obtained two sub-groups of patients with schizophrenia, with (Schiz-Axial, N = 26), and without parkinsonian axial signs (Schiz-NO-Axial, N = 273). Clinical and demographical variables were compared between groups. The motor section of the Unified Parkinson's disease rating scale (UPDRS) was employed to measure motor disability. Schiz-Axial patients were significantly older (p = 0.007) and had longer disease duration (p = 0.04) compared to Schiz-NO-Axial. The two groups did not differ for variables related to AP treatment. Total UPDRS motor score (p signs might be an early manifestation of parkinsonism in schizophrenia associated to older age and longer disease duration. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Dropped head congenital muscular dystrophy caused by de novo mutations in LMNA.

    Science.gov (United States)

    Karaoglu, Pakize; Quizon, Nicolas; Pergande, Matthias; Wang, Haicui; Polat, Ayşe Ipek; Ersen, Ayca; Özer, Erdener; Willkomm, Lena; Hiz Kurul, Semra; Heredia, Raúl; Yis, Uluç; Selcen, Duygu; Çirak, Sebahattin

    2017-04-01

    Dropped head syndrome is an easily recognizable clinical presentation of Lamin A/C-related congenital muscular dystrophy. Patients usually present in the first year of life with profound neck muscle weakness, dropped head, and elevated serum creatine kinase. Two patients exhibited head drop during infancy although they were able to sit independently. Later they developed progressive axial and limb-girdle weakness. Creatine kinase levels were elevated and muscle biopsies of both patients showed severe dystrophic changes. The distinctive clinical hallmark of the dropped head led us to the diagnosis of Lamin A/C-related congenital muscular dystrophy, with a pathogenic de novo mutation p.Glu31del in the head domain of the Lamin A/C gene in both patients. Remarkably, one patient also had a central involvement with white matter changes on brain magnetic resonance imaging. Lamin A/C-related dropped-head syndrome is a rapidly progressive congenital muscular dystrophy and may lead to loss of ambulation, respiratory insufficiency, and cardiac complications. Thus, the genetic diagnosis of dropped-head syndrome as L-CMD and the implicated clinical care protocols are of vital importance for these patients. This disease may be underdiagnosed, as only a few genetically confirmed cases have been reported. Copyright © 2016 The Japanese Society of Child Neurology. Published by Elsevier B.V. All rights reserved.

  16. Fluorescence axial nanotomography with plasmonics.

    Science.gov (United States)

    Cade, Nicholas I; Fruhwirth, Gilbert O; Krasavin, Alexey V; Ng, Tony; Richards, David

    2015-01-01

    We present a novel imaging technique with super-resolution axial sensitivity, exploiting the changes in fluorescence lifetime above a plasmonic substrate. Using conventional confocal fluorescence lifetime imaging, we show that it is possible to deliver down to 6 nm axial position sensitivity of fluorophores in whole biological cell imaging. We employ this technique to map the topography of the cellular membrane, and demonstrate its application in an investigation of receptor-mediated endocytosis in carcinoma cells.

  17. Evaluation of radiotherapy methods for adaptative head and neck treatment with RapidArc®; Avaliacao de uma metodologia de radioterapia adaptativa para tratamentos de cabeca e pescoco com RapidArc®

    Energy Technology Data Exchange (ETDEWEB)

    Mazaro, Sarah J.; Vasconcellos, Herminiane L.; Silva, Laura E. da; Bastos, Fernanda M.; Silva, Leonardo P. da; Alvaro S; Migoviski, Igor, E-mail: sarahmazaro@yahoo.com.br [Instituto Nacional de Cancer Jose de Alencar Gomes da Silva (INCA), Rio de Janeiro,RJ (Brazil)

    2015-08-15

    Head and neck cancer is considered a public health problem worldwide. The intensity-modulated techniques have shown benefit in the treatment of these sites, particularly with respect to reduction of deterministic effects of risk, such as parotid. Anatomical variations in cases of head and neck are very frequent and may lead, for example, to an overdose in the parotid. This can be mitigated if making use of adaptive radiation therapy. The work aims to analyze a methodology to redo the planning of treatments, through 02 acquisitions of TC. The results showed that, due to a reduction in the volumes of the parotid, the doses delivered to these organs are underestimated, which is relevant to readapt the treatment, with the addition of only a second scan without the need of the third. (author)

  18. Axial Permanent Magnet Generator for Wearable Energy Harvesting

    DEFF Research Database (Denmark)

    Högberg, Stig; Sødahl, Jakob Wagner; Mijatovic, Nenad

    2016-01-01

    An increasing demand for battery-free electronics is evident by the rapid increase of wearable devices, and the design of wearable energy harvesters follows accordingly. An axial permanent magnet generator was designed to harvest energy from human body motion and supplying it to a wearable...... application. The design was approached from an lectromagnetic point of view in this article. Two types of axial flux permanent magnet generators were designed: one with an iron yoke, which is commonly used to reduce the machine volume and demand of permanent magnets, and a second without the iron yoke...

  19. Experimental Studies on Strength Behaviour of Notched Glass/Epoxy Laminated Composites under Uni-axial and Bi-axial Loading

    Science.gov (United States)

    Guptha, V. L. Jagannatha; Sharma, Ramesh S.

    2017-11-01

    The use of FRP composite materials in aerospace, aviation, marine, automotive and civil engineering industry has increased rapidly in recent years due to their high specific strength and stiffness properties. The structural members contrived from such composite materials are generally subjected to complex loading conditions and leads to multi-axial stress conditions at critical surface localities. Presence of notches, much required for joining process of composites, makes it further significant. The current practice of using uni-axial test data alone to validate proposed material models is inadequate leading to evaluation and consideration of bi-axial test data. In order to correlate the bi-axial strengths with the uni-axial strengths of GFRP composite laminates in the presence of a circular notch, bi-axial tests using four servo-hydraulic actuators with four load cells were carried out. To determine the in-plane strength parameters, bi-axial cruciform test specimen model was considered. Three different fibre orientations, namely, 0°, 45°, and 90° are considered with a central circular notch of 10 mm diameter in the present investigation. From the results obtained, it is observed that there is a reduction in strength of 5.36, 2.41 and 13.92% in 0°, 45°, and 90° fibre orientation, respectively, under bi-axial loading condition as compared to that of uni-axial loading in laminated composite.

  20. Axial structure of the nucleon

    Energy Technology Data Exchange (ETDEWEB)

    Veronique Bernard; Latifa Elouadrhiri; Ulf-G Meissner

    2002-01-01

    We review the current status of experimental and theoretical understanding of the axial nucleon structure at low and moderate energies. Topics considered include (quasi)elastic (anti)neutrino-nucleon scattering, charged pion electroproduction off nucleons and ordinary as well as radiative muon capture on the proton.

  1. A simple and rapid LC-MS/MS method for therapeutic drug monitoring of cetuximab: a GPCO-UNICANCER proof of concept study in head-and-neck cancer patients.

    Science.gov (United States)

    Becher, François; Ciccolini, Joseph; Imbs, Diane-Charlotte; Marin, Clémence; Fournel, Claire; Dupuis, Charlotte; Fakhry, Nicolas; Pourroy, Bertrand; Ghettas, Aurélie; Pruvost, Alain; Junot, Christophe; Duffaud, Florence; Lacarelle, Bruno; Salas, Sebastien

    2017-06-02

    Administration of first-in-class anti-EGFR monoclonal antibody cetuximab is contingent upon extensive pharmacogenomic testing. However in addition to tumor genomics, drug exposure levels could play a critical, yet largely underestimated role, because several reports have demonstrated that cetuximab pharmacokinetic parameters, in particular clearance values, were associated with survival in patients. Here, we have developed an original bioanalytical method based upon the use of LC-MS/MS technology and a simplified sample preparation procedure to assay cetuximab in plasma samples from patients, thus meeting the requirements of standard Therapeutic Drug Monitoring in routine clinical practice. When tested prospectively in a pilot study in 25 head-and-neck cancer patients, this method showed that patients with clinical benefit had cetixumab residual concentrations higher than non-responding patients (i.e., 49 ± 16.3 µg/ml VS. 25.8 ± 17 µg/ml, p < 0.01 t test). Further ROC analysis showed that 33.8 µg/ml was the Cmin threshold predictive of response with an acceptable sensitivity (87%) and specificity (78%). Mass spectrometry-based therapeutic drug monitoring of cetuximab in head-and-neck cancer patients could therefore help to rapidly predict cetuximab efficacy and to adapt dosing if required.

  2. Optimal design of multi-conditions for axial flow pump

    Science.gov (United States)

    Shi, L. J.; Tang, F. P.; Liu, C.; Xie, R. S.; Zhang, W. P.

    2016-11-01

    Passage components of the pump device will have a negative flow state when axial pump run off the design condition. Combined with model tests of axial flow pump, this paper use numerical simulation and numerical optimization techniques, and change geometric design parameters of the impeller to optimal design of multi conditions for Axial Flow Pump, in order to improve the efficiency of non-design conditions, broad the high efficient district and reduce operating cost. The results show that, efficiency curve of optimized significantly wider than the initial one without optimization. The efficiency of low flow working point increased by about 2.6%, the designed working point increased by about 0.5%, and the high flow working point increased the most, about 7.4%. The change range of head is small, so all working point can meet the operational requirements. That will greatly reduce operating costs and shorten the period of optimal design. This paper adopted the CFD simulation as the subject analysis, combined with experiment study, instead of artificial way of optimization design with experience, which proves the reliability and efficiency of the optimization design of multi-operation conditions of axial-flow pump device.

  3. Head Injuries

    Science.gov (United States)

    ... ATV) Safety Balance Disorders Knowing Your Child's Medical History First Aid: Falls First Aid: Head Injuries Preventing Children's Sports Injuries Getting Help: Know the Numbers Concussions Stay ...

  4. Quasi-axially symmetric stellarators

    Science.gov (United States)

    Garabedian, Paul R.

    1998-01-01

    Confinement of a plasma for controlled thermonuclear fusion is studied numerically. Toroidal equilibria are considered, with an emphasis on the Modular Helias-like Heliac 2 (MHH2), which is a stellarator of low aspect ratio with just two field periods surrounded by 16 modular coils. The geometry is fully three-dimensional, but there is an axial symmetry of the magnetic structure that is calculated to give confinement competitive with that in circular tokamaks. Additional vertical and toroidal field coils, together with a current drive, provide the flexibility and the control of rotational transform necessary for a successful experiment. An MHH3 device with three field periods and comparable quasi-axial symmetry is presented, too, and because of reversed shear, its physical properties may be better. Variational analysis of equilibrium and stability is shown to give a more reliable prediction of performance for these stellarators than linearized or local theories that suffer from a failure of differentiability and convergence. PMID:9707544

  5. About "axial" and "radial" diffusivities.

    Science.gov (United States)

    Wheeler-Kingshott, Claudia A M; Cercignani, Mara

    2009-05-01

    This article presents the potential problems arising from the use of "axial" and "radial" diffusivities, derived from the eigenvalues of the diffusion tensor, and their interpretation in terms of the underlying biophysical properties, such as myelin and axonal density. Simulated and in vivo data are shown. The simulations demonstrate that a change in "radial" diffusivity can cause a fictitious change in "axial" diffusivity and vice versa in voxels characterized by crossing fibers. The in vivo data compare the direction of the principle eigenvector in four different subjects, two healthy and two affected by multiple sclerosis, and show that the angle, alpha, between the principal eigenvectors of corresponding voxels of registered datasets is greater than 45 degrees in areas of low anisotropy, severe pathology, and partial volume. Also, there are areas of white matter pathology where the "radial" diffusivity is 10% greater than that of the corresponding normal tissue and where the direction of the principal eigenvector is altered by more than 45 degrees compared to the healthy case. This should strongly discourage researchers from interpreting changes of the "axial" and "radial" diffusivities on the basis of the underlying tissue structure, unless accompanied by a thorough investigation of their mathematical and geometrical properties in each dataset studied. (c) 2009 Wiley-Liss, Inc.

  6. Head Lice

    Science.gov (United States)

    ... 1044-1047. Canyon, DV, Speare R, et al . “Spatial and kinetic factors for the transfer of head ... for children. Natural products can give parents false sense of safety If using a natural product or ...

  7. Traumatic injuries: imaging of head injuries

    Energy Technology Data Exchange (ETDEWEB)

    Besenski, N. [Croatian Institute for Brain Research, Zagreb (Croatia)

    2002-06-01

    Due to the forces of acceleration, linear translation, as well as rotational and angular acceleration, the brain undergoes deformation and distortion depending on the site of impact of traumatizing force direction, severity of the traumatizing force, and tissue resistance of the brain. Linear translation of accereration in a closed-head injury can run along the shorter diameter of the skull in latero-lateral direction causing mostly extra-axial lesions (subdural hematoma,epidural hematoma, subarachnoidal hemorrhage) or quite pronounced coup and countercoup contusions. Contusions are considerably less frequently present in medial or paramedial centroaxial blows (fronto-occipital or occipito-frontal). The centroaxial blows produce a different pattern of lesions mostly in the deep structures, causing in some cases a special category of the brain injury, the diffuse axonal injury (DAI). The brain stem can also be damaged, but it is damaged more often in patients who have suffered centroaxial traumatic force direction. Computed tomography and MRI are the most common techniques in patients who have suffered brain injury. Computed tomography is currently the first imaging technique to be used after head injury, in those settings where CT is available. Using CT, scalp, bone, extra-axial hematomas, and parenchymal injury can be demonstrated. Computed tomography is rapid and easily performed also in monitored patients. It is the most relevant imaging procedure for surgical lesions. Computed tomography is a suitable method to follow the dynamics of lesion development giving an insight into the corresponding pathological development of the brain injury. Magnetic resonance imaging is more sensitive for all posttraumatic lesions except skull fractures and subarachnoidal hemorrhage, but scanning time is longer, and the problem with the monitoring of patients outside the MRI field is present. If CT does not demonstrate pathology as can adequately be explained to account for

  8. Axial vector Z‧ and anomaly cancellation

    Science.gov (United States)

    Ismail, Ahmed; Keung, Wai-Yee; Tsao, Kuo-Hsing; Unwin, James

    2017-05-01

    Whilst the prospect of new Z‧ gauge bosons with only axial couplings to the Standard Model (SM) fermions is widely discussed, examples of anomaly-free renormalisable models are lacking in the literature. We look to remedy this by constructing several motivated examples. Specifically, we consider axial vectors which couple universally to all SM fermions, as well as those which are generation-specific, leptophilic, and leptophobic. Anomaly cancellation typically requires the presence of new coloured and charged chiral fermions, and we argue that in a large class of models masses of these new states are expected to be comparable to that of the axial vector. Finally, an axial vector mediator could provide a portal between SM and hidden sector states, and we also consider the possibility that the axial vector couples to dark matter. If the dark matter relic density is set due to freeze-out via the axial vector, this strongly constrains the parameter space.

  9. Mathematical Modeling of a Blood Flow in Flow Path of the Axial Pump of Ventricular Assist Device

    OpenAIRE

    A. M. Guskov; F. D. Sorokin; E. P. Banin; A. E. Krupnin

    2015-01-01

    The research object is an axial left ventricular assist device (LVAD) design such as: straightener, impeller, and diffuser.The objective of the study is to reveal an influence of axial LVAD pump’s impeller design factors such as pitch and incidence on head-capacity curves and stagnation and hemolysis zones generation. The mathematical modeling is carried out by computational fluid dynamics analysis in a stationary setting.The study concentrates on mathematical modeling of a blood flow in flow...

  10. Centrifugal and axial pump design and off-design performance prediction

    Science.gov (United States)

    Veres, Joseph P.

    1994-10-01

    A meanline pump flow modeling method has been developed to provide a fast capability for modeling pumps of cryogenic rocket engines. Based on this method, a meanline pump flow code PUMPA has been written that can predict the performance of pumps at off-design operating conditions, given the loss of the diffusion system at the design point. The design point rotor efficiency and slip factor are obtained from empirical correlations to rotor specific speed and geometry. The pump code can model axial or inducer, mixed-flow and centrifugal pumps. The code can model multi-stage pumps in series. The rapid input setup and computer run time for the meanline pump flow code makes it an effective analysis and conceptual design tool. The map generation capabilities of the code provides the information needed for interfacing with a rocket engine system modeling code. The off-design and multi-stage modeling capabilities of the code permit the user to do parametric design space exploration of candidate pump configurations and provide head-flow maps for engine system evaluation.

  11. Electric machines with axial magnetic flux

    Science.gov (United States)

    Nuca, I.; Ambros, T.; Burduniuc, M.; Deaconu, S. I.; Turcanu, A.

    2018-01-01

    The paper contains information on the performance of axial machines compared to cylindrical ones. At the same time, various constructive schemes of synchronous electromechanical converters with permanent magnets and asynchronous with short-circuited rotor are presented. In the developed constructions, the aim is to maximize the usage of the material of the stator windings. The design elements of the axial machine magnetic system are presented. The FEMM application depicted the array of the magnetic field of an axial machine.

  12. Centrifugal and axial compressor control

    CERN Document Server

    McMillan, Gregory K

    2009-01-01

    Control engineers, mechanical engineers and mechanical technicians will learn how to select the proper control systems for axial and centrifugal compressors for proper throughput and surge control, with a particular emphasis on surge control. Readers will learn to understand the importance of transmitter speed, digital controller sample time, and control valve stroking time in helping to prevent surge. Engineers and technicians will find this book to be a highly valuable guide on compressor control schemes and the importance of mitigating costly and sometimes catastrophic surge problems. It can be used as a self-tutorial guide or in the classroom with the book's helpful end-of-chapter questions and exercises and sections for keeping notes.

  13. The Emergence of Axial Parts

    Directory of Open Access Journals (Sweden)

    Peter Svenonius

    2007-01-01

    Full Text Available Many languages have specialized locative words or morphemes translating roughly into words like ‘front,’ ‘back,’ ‘top,’ ‘bottom,’ ‘side,’ and so on. Often, these words are used instead of more specialized adpositions to express spatial meanings corresponding to ‘behind,’ ‘above,’ and so on. I argue, on the basis of a cross-linguistic survey of such expressions, that in many cases they motivate a syntactic category which is distinct from both N and P, which I call AxPart for ‘Axial Part’; I show how the category relates to the words which instantiate it, and how the meaning of the construction is derived from the combination of P[lace] elements, AxParts, and the lexical material which expresses them.

  14. Bone Disease in Axial Spondyloarthritis.

    Science.gov (United States)

    Van Mechelen, Margot; Gulino, Giulia Rossana; de Vlam, Kurt; Lories, Rik

    2017-10-31

    Axial spondyloarthritis is a chronic inflammatory skeletal disorder with an important burden of disease, affecting the spine and sacroiliac joints and typically presenting in young adults. Ankylosing spondylitis, diagnosed by the presence of structural changes to the skeleton, is the prototype of this disease group. Bone disease in axial spondyloarthritis is a complex phenomenon with the coexistence of bone loss and new bone formation, both contributing to the morbidity of the disease, in addition to pain caused by inflammation. The skeletal structural changes respectively lead to increased fracture risk and to permanent disability caused by ankylosis of the sacroiliac joints and the spine. The mechanism of this new bone formation leading to ankylosis is insufficiently known. The process appears to originate from entheses, specialized structures that provide a transition zone in which tendon and ligaments insert into the underlying bone. Growth factor signaling pathways such as bone morphogenetic proteins, Wnts, and Hedgehogs have been identified as molecular drivers of new bone formation, but the relationship between inflammation and activation of these pathways remains debated. Long-standing control of inflammation appears necessary to avoid ankylosis. Recent evidence and concepts suggest an important role for biomechanical factors in both the onset and progression of the disease. With regard to new bone formation, these processes can be understood as ectopic repair responses secondary to inflammation-induced bone loss and instability. In this review, we discuss the clinical implications of the skeletal changes as well as the underlying molecular mechanisms, the relation between inflammation and new bone formation, and the potential role of biomechanical stress.

  15. Improving axial depth of cut accuracy in micromilling

    DEFF Research Database (Denmark)

    Bissacco, Giuliano; Hansen, Hans Nørgaard; De Chiffre, Leonardo

    2004-01-01

    In order to maintain an optimum cutting speed, the reduction of mill diameters requires machine tools with high rotational speed capabilities. A solution to update existing machine tools is the use of high speed attached spindles. Major drawbacks of these attachments are the high thermal expansion...... and their rapid warming and cooling, which prevent the achievement of a steady state. Several other factors, independent on the tool-workpiece interaction, influence the machining accuracy. The cutting parameter most heavily affected is the axial depth of cut which is the most critical when using micro end mills...... provided with conventional milling machines. This paper presents an investigation aimed at the reduction of the error on the axial depth of cut in micromilling operations, in a workshop environment. A method for tool length correction with sub-micrometer resolution by use of an inductive probe...

  16. Severe Intraoperative Hypercapnia Complicating an Unsual Malfunction of the Inner Tube of a Co-axial (BAIN'S Circuit

    Directory of Open Access Journals (Sweden)

    Youssef Emam Youssef

    2010-04-01

    Full Text Available The Bain's co-axial circuit system is fully established in general anaesthesia practice. It is favoured for its light weight and suitability for head and neck surgery. However, there are numerous published reports of malfunction of the inner tube of the Bain's co-axial circuit, with potentially lethal complications for the patient. This report presents a case in which a patient connected to a reused Bain's circuit (Datex-Ohmeda developed severe hypercapnia in the early intraoperative period due to unusual defect of the inner tube. This report tests and outlines the integrity of co-axial circuits and also reviews the available literature.

  17. Head Start.

    Science.gov (United States)

    Greenman, Geri

    2000-01-01

    Discusses an art project in which students created drawings of mop heads. Explains that the approach of drawing was more important than the subject. States that the students used the chiaroscuro technique, used by Rembrandt and Caravaggio, in which light appears out of the darkness. (CMK)

  18. Health and imaging outcomes in axial spondyloarthritis

    NARCIS (Netherlands)

    Machado, P.M.

    2016-01-01

    This thesis focuses on the assessment and monitoring of health and imaging outcomes in axial spondyloarthritis (SpA) and the relationship between these outcomes. Four major contributions to the understanding and management of axial SpA were made: 1) the improvement and facilitation of the assessment

  19. A study on the mechanical properties of beagle femoral head using the digital speckle correlation method.

    Science.gov (United States)

    Wang, Qinghua; Xie, Huimin; Tang, Peifu; Yao, Qi; Huang, Peng; Chen, Pengwan; Huang, Fenglei

    2009-12-01

    The mechanical properties of the femoral head are known to play an important role in the athletic performance of animals. In this paper, the full-field displacement and strain distributions of beagle femoral head samples in the U and V fields under loading were measured using the digital speckle correlation method (DSCM), and some deformation characteristics were analyzed. Young's modulus and Poisson's ratio were calculated to demonstrate the notable axial anisotropy of the femoral head. The axial compressive Young's modulus varies from 361MPa to 583MPa, and the transverse one is 213MPa. The Poisson's ratio in the axial-transverse direction ranges from 0.14 to 0.29, and the one in the transverse-axial direction is 0.07. Experimental results validated the accuracy of this measurement, providing a potential reference for investigating the deformation performance of the femoral head.

  20. Axial anomalies of Lifshitz fermions

    CERN Document Server

    Bakas, Ioannis

    2011-01-01

    We compute the axial anomaly of a Lifshitz fermion theory with anisotropic scaling z=3 which is minimally coupled to geometry in 3+1 space-time dimensions. We find that the result is identical to the relativistic case using path integral methods. An independent verification is provided by showing with spectral methods that the eta-invariant of the Dirac and Lifshitz fermion operators in three dimensions are equal. Thus, by the integrated form of the anomaly, the index of the Dirac operator still accounts for the possible breakdown of chiral symmetry in non-relativistic theories of gravity. We apply this framework to the recently constructed gravitational instanton backgrounds of Horava-Lifshitz theory and find that the index is non-zero provided that the space-time foliation admits leaves with harmonic spinors. Using Hitchin's construction of harmonic spinors on Berger spheres, we obtain explicit results for the index of the fermion operator on all such gravitational instanton backgrounds with SU(2)xU(1) isom...

  1. Dynamic axial stabilization of counterpropagating beam-traps with feedback control

    DEFF Research Database (Denmark)

    Tauro, Sandeep; Bañas, Andrew Rafael; Palima, Darwin

    2010-01-01

    . Here we propose a dynamic method for controlling axial forces to overcome this constraint. The technique uses computervision object tracking of the axial position, in conjunction with softwarebased feedback, for dynamically stabilizing the axial forces. We present proof-of-concept experiments showing...... real-time rapid repositioning coupled with a strongly enhanced axial trapping for a plurality of particles of varying sizes. We also demonstrate the technique’s adaptability for real-time reconfigurable feedback-trapping of a dynamically growing structure that mimics a continuously dividing cell colony....... Advanced implementation of this feedback-driven approach can help make CP-trapping resistant to a host of perturbations such as laser fluctuations, mechanical vibrations and other distortions emphasizing its experimental versatility....

  2. Axial Flow Conditioning Device for Mitigating Instabilities

    Science.gov (United States)

    Ahuja, Vineet (Inventor); Birkbeck, Roger M. (Inventor); Hosangadi, Ashvin (Inventor)

    2017-01-01

    A flow conditioning device for incrementally stepping down pressure within a piping system is presented. The invention includes an outer annular housing, a center element, and at least one intermediate annular element. The outer annular housing includes an inlet end attachable to an inlet pipe and an outlet end attachable to an outlet pipe. The outer annular housing and the intermediate annular element(s) are concentrically disposed about the center element. The intermediate annular element(s) separates an axial flow within the outer annular housing into at least two axial flow paths. Each axial flow path includes at least two annular extensions that alternately and locally direct the axial flow radially outward and inward or radially inward and outward thereby inducing a pressure loss or a pressure gradient within the axial flow. The pressure within the axial flow paths is lower than the pressure at the inlet end and greater than the vapor pressure for the axial flow. The invention minimizes fluidic instabilities, pressure pulses, vortex formation and shedding, and/or cavitation during pressure step down to yield a stabilized flow within a piping system.

  3. "E" Heating Head

    Science.gov (United States)

    Fox, Robert L.; Swaim, Robert J.; Johnson, Samuel D.; Coultrip, Robert H.; Phillips, W. Morris; Copeland, Carl E.

    1994-01-01

    Two separate areas heated inductively for adhesive bonding in single operation. "E" heating head developed to satisfy need for fast-acting and reliable induction heating device. Used in attaching "high-hat" stiffeners to aircraft panels. Incorporates principles and circuitry of toroid joining gun. Width and length configured to provide variously sized heat zones, depending on bonding requirements. Lightweight, portable and provides rapid, reliable heating of dual areas in any environment. Well suited for flight-line and depot maintenance, and battlefield repair. Also useful in automotive assembly lines to strengthen automobile panels.

  4. Is HEADS in our heads?

    DEFF Research Database (Denmark)

    Boisen, Kirsten A; Hertz, Pernille Grarup; Blix, Charlotte

    2016-01-01

    BACKGROUND: Outpatient clinic visits are a window of opportunity to address health risk behaviors and promote a healthier lifestyle among young people. The HEADS (Home, Education, Eating, Activities, Drugs [i.e. substance use including tobacco, alcohol, and illegal drugs], Sexuality [including...... contraception], Safety, Self-harm) interview is a feasible way of exploring health risk behaviors and resilience. OBJECTIVE: The purpose of this study was to evaluate how often HEADS topics were addressed according to young patients and staff in pediatric and adult outpatient clinics. METHODS: We conducted...... care professionals participated. We found only small reported differences between staff and young patients regarding whether home, education, and activity were addressed. However, staff reported twice the rate of addressing smoking, alcohol, illegal drugs, sexuality, and contraception compared to young...

  5. Simulation of cavitation performance of an axial flow pump with inlet guide vanes

    Directory of Open Access Journals (Sweden)

    Weimin Feng

    2016-05-01

    Full Text Available The cavitation performance of an axial flow pump with inlet guide vanes for different flow rates is studied in this article. The effects of inlet guide vanes on pump hydraulic performance and cavitation are investigated, where the total vapor fraction of impeller zone (Ftv is calculated to predict the critical net positive suction head, which is compared with that predicted by efficiency criterion for different flow rates. The influences of the development of cavitation on internal flow in impeller zone are also investigated. The results obtained show that the cavitation performance of axial flow pump can be improved at off-design flow conditions by adjusting angles of inlet guide vanes to positive values at low flow rates and by regulating angles of inlet guide vanes to negative values at high flow rates. As the net positive suction head decreases, the vapor fraction first increases slowly and then increases greatly, clearly presenting cavitation process from inception to full development, which can be used to predict the required net positive suction head. When net positive suction head decreases to the value around required net positive suction head, the cavitation zone from tip of blade suction side close to leading edge and the cavitation zone from hub part of the blade suction side connect together. After the connection, the cavitation zones have great influence on the velocity flow, leading to the decrease in pump performance.

  6. Axial Super-resolution Evanescent Wave Tomography

    CERN Document Server

    Pendharker, Sarang; Newman, Ward; Ogg, Stephen; Nazemifard, Neda; Jacob, Zubin

    2016-01-01

    Optical tomographic reconstruction of a 3D nanoscale specimen is hindered by the axial diffraction limit, which is 2-3 times worse than the focal plane resolution. We propose and experimentally demonstrate an axial super-resolution evanescent wave tomography (AxSET) method that enables the use of regular evanescent wave microscopes like Total Internal Reflection Fluorescence Microscope (TIRF) beyond surface imaging, and achieve tomographic reconstruction with axial super-resolution. Our proposed method based on Fourier reconstruction achieves axial super-resolution by extracting information from multiple sets of three-dimensional fluorescence images when the sample is illuminated by an evanescent wave. We propose a procedure to extract super-resolution features from the incremental penetration of an evanescent wave and support our theory by 1D (along the optical axis) and 3D simulations. We validate our claims by experimentally demonstrating tomographic reconstruction of microtubules in HeLa cells with an axi...

  7. Simulation of cavitation performance of an axial flow pump with inlet guide vanes

    OpenAIRE

    Weimin Feng; Qian Cheng; Zhiwei Guo; Zhongdong Qian

    2016-01-01

    The cavitation performance of an axial flow pump with inlet guide vanes for different flow rates is studied in this article. The effects of inlet guide vanes on pump hydraulic performance and cavitation are investigated, where the total vapor fraction of impeller zone (Ftv) is calculated to predict the critical net positive suction head, which is compared with that predicted by efficiency criterion for different flow rates. The influences of the development of cavitation on internal flow in i...

  8. High harmonic generation from axial chiral molecules.

    Science.gov (United States)

    Wang, Dian; Zhu, Xiaosong; Liu, Xi; Li, Liang; Zhang, Xiaofan; Lan, Pengfei; Lu, Peixiang

    2017-09-18

    Axial chiral molecules, whose stereogenic element is an axis rather than a chiral center, have attracted widespread interest due to their important application, such as asymmetric synthesis and chirality transfer. We investigate high harmonic generation from axial chiral molecules with bichromatic counterrotating circularly polarized laser fields. High harmonic generation from three typical molecules: (Sa)-3-chloropropa-1,2-dien-1-ol, propadiene, and (Ra)-2,3-pentadiene is simulated with time-dependent density-functional theory and strong field approximation. We found that harmonic spectra for 3D oriented axial chiral molecules exhibit obvious circular dichroism. However, the circular dichroism of High harmonic generation from an achiral molecule is much trivial. Moreover, the dichroism of high harmonic generation still exists when axial chiral molecules are 1D oriented,such as (Sa) -3-chloropropa-1,2-dien-1-ol. For a special form of axial chiral molecules with the formula abC=C=Cab (a, b are different substituents), like (Ra)-2,3-pentadiene, the dichroism discriminations disappear when the molecules are only in 1D orientation. The circular dichroism of high harmonic generation from axial chiral molecules is well explained by the trajectory analysis based on the semiclassical three-step mechanism.

  9. An analysis of the extension of a ZnO piezoelectric semiconductor nanofiber under an axial force

    Science.gov (United States)

    Zhang, Chunli; Wang, Xiaoyuan; Chen, Weiqiu; Yang, Jiashi

    2017-02-01

    This paper presents a theoretical analysis on the axial extension of an n-type ZnO piezoelectric semiconductor nanofiber under an axial force. The phenomenological theory of piezoelectric semiconductors consisting of Newton’s second law of motion, the charge equation of electrostatics and the conservation of charge was used. The equations were linearized for small axial force and hence small electron concentration perturbation, and were reduced to one-dimensional equations for thin fibers. Simple and analytical expressions for the electromechanical fields and electron concentration in the fiber were obtained. The fields are either totally or partially described by hyperbolic functions relatively large near the ends of the fiber and change rapidly there. The behavior of the fields is sensitive to the initial electron concentration and the applied axial force. For higher initial electron concentrations the fields are larger near the ends and change more rapidly there.

  10. Optimization of residual heat removal pump axial thrust and axial bearing

    Energy Technology Data Exchange (ETDEWEB)

    Schubert, F.

    1996-12-01

    The residual heat removal (RHR) pumps of German 1300 megawatt pressurized-water reactor (PWR) power plants are of the single stage end suction type with volute casing or with diffuser and forged circular casing. Due to the service conditions the pumps have to cover the full capacity range as well as a big variation in suction static pressure. This results in a big difference in the axial thrust that has to be borne by the axial bearing. Because these pumps are designed to operate without auxiliary systems (things that do not exist can not fail), they are equipped with antifriction bearings and sump oil lubrication. To minimize the heat production within the bearing casing, a number of PWR plants have pumps with combined axial/radial bearings of the ball type. Due to the fact that the maximum axial thrust caused by static pressure and hydrodynamic forces on the impeller is too big to be borne by that type of axial bearing, the impellers were designed to produce a hydrodynamic axial force that counteracts the static axial force. Thus, the resulting axial thrust may change direction when the static pressure varies.

  11. Axial Vircator for Electronic Warfare Applications

    Directory of Open Access Journals (Sweden)

    L. Drazan

    2009-12-01

    Full Text Available This paper deals with a high power microwave generator with virtual cathode – vircator in axial release for electronic warfare applications. The classification of directed energy weapons microwave (DEWM is introduced together with basic block diagrams of a particular class of DEWM. In the paper, methods for designing vircator pulsed power supply, axial vircator structure, measurement methods and experimental results are presented. The vircator in electromagnetic ammunition is powered by magneto-cumulative generator and in weapons for defense of objects (WDO, it is powered by Marx generator. The possible applications of a vircator in the DEWM area are discussed.

  12. Axial pico turbine - construction and experimental research

    Science.gov (United States)

    Peczkis, G.; Goryca, Z.; Korczak, A.

    2017-08-01

    The paper concerns axial water turbine of power equal to 1 kW. The example of axial water turbine constructional calculations was provided, as well as turbine rotor construction with NACA profile blades. The laboratory test rig designed and built to perform measurements on pico turbine was described. The turbine drove three-phase electrical generator. On the basis of highest efficiency parameters, pico turbine basic characteristics were elaborated. The experimental research results indicated that pico turbine can achieve maximum efficiency close to the values of larger water turbines.

  13. Axial force measurement for esophageal function testing

    DEFF Research Database (Denmark)

    Gravesen, Flemming Holbæk; Funch-Jensen, Peter; Gregersen, Hans

    2009-01-01

    The esophagus serves to transport food and fluid from the pharynx to the stomach. Manometry has been the "golden standard" for the diagnosis of esophageal motility diseases for many decades. Hence, esophageal function is normally evaluated by means of manometry even though it reflects the squeeze...... force (force in radial direction) whereas the bolus moves along the length of esophagus in a distal direction. Force measurements in the longitudinal (axial) direction provide a more direct measure of esophageal transport function. The technique used to record axial force has developed from external...

  14. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... of the Head? What is CT Scanning of the Head? Computed tomography, more commonly known as a ... of page What are some common uses of the procedure? CT scanning of the head is typically ...

  15. Head Impact Laboratory (HIL)

    Data.gov (United States)

    Federal Laboratory Consortium — The HIL uses testing devices to evaluate vehicle interior energy attenuating (EA) technologies for mitigating head injuries resulting from head impacts during mine/...

  16. Regularities of axially-periodical magnetic field of a betatron

    Energy Technology Data Exchange (ETDEWEB)

    Zvontsov, A.A.; Filinova, V.A.; Chakhlov, V.L. (Tomskij Politekhnicheskij Inst. (USSR). Nauchno-Issledovatel' skij Inst. Ehlektronnoj Introskopii)

    1983-07-01

    Consideration is being given to the possibility of increasing the stability region of particle motion in a betatron with an axially-periodic magnetic field. The damping of radial betatron oscillations is accomplished by variation of the index guiding magnetic field drop-off according to z-coordinate and the instability effect is reduced by the beam separation when separate beams, are being accelerated in ''proper'' equilibrium orbits, organized in parallel z-planes. It is shown on the base of solution of the equation for vector potential of magnetic field that under certain conditions focusing properties of betatron magnetic field have spacing character according to z-coordinate. The expression for the determination of the distance between equilibrium orbit planes for the given orbit radius and the of field drop-off was obtained. Peculiarities of operation of such accelerator were described. Betatrons with axially-periodic guiding field can generate one intense pulse of radiation or several pulses of lower density with regulated time intervals between them and can be used, for example, for film-roentgenography of rapid processes.

  17. Developmental morphology of the axial skeleton of the zebrafish, Danio rerio (Ostariophysi: Cyprinidae).

    Science.gov (United States)

    Bird, Nathan C; Mabee, Paula M

    2003-11-01

    Before our rapidly increasing knowledge of gene interactions can be connected with the morphologic defects in mutant zebrafish, the normal course of skeletal development must be understood. Here, we describe the developmental morphology of the axial skeleton of zebrafish and review it in relation to the morphology of related species. The relative sequence of ossification in the skeleton is described. Two separate centers of development were found in the axial skeleton (Weberian apparatus and caudal fin) in contrast to tetrapods, which have a single anterior center. Slight variation was found in the overall relative timing of development. The extensive ichthyological literature on teleost anatomy and recent genetic data form the basis for our review and interpretation of homologies of various elements of the axial skeleton. Because homology forms the basis for all evolutionary comparisons, these data are critical for integration in evo-devo studies. Copyright 2003 Wiley-Liss, Inc.

  18. Aryabha~ and Axial Rotation of Earth

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 11; Issue 4. Aryabhata and Axial Rotation of Earth - Naksatra Dina (the Sidereal Day). Amartya Kumar Dutta. General Article Volume 11 Issue 4 April 2006 pp 56-74. Fulltext. Click here to view fulltext PDF. Permanent link:

  19. Wave propagation in axially moving periodic strings

    DEFF Research Database (Denmark)

    Sorokin, Vladislav S.; Thomsen, Jon Juel

    2017-01-01

    The paper deals with analytically studying transverse waves propagation in an axially moving string with periodically modulated cross section. The structure effectively models various relevant technological systems, e.g. belts, thread lines, band saws, etc., and, in particular, roller chain drive...

  20. Co-axial, high energy gamma generator

    Science.gov (United States)

    Reijonen, Jani Petteri [Princeton, NJ; Gicquel, Frederic [Pennington, NJ

    2011-08-16

    A gamma ray generator includes an ion source in a first chamber. A second chamber is configured co-axially around the first chamber at a lower second pressure. Co-axially arranged plasma apertures separate the two chambers and provide for restricted passage of ions and gas from the first to the second chamber. The second chamber is formed by a puller electrode having at least one long channel aperture to draw ions from the first chamber when the puller electrode is subject to an appropriate applied potential. A plurality of electrodes rings in the third chamber in third pressure co-axially surround the puller electrode and have at least one channel corresponding to the at least one puller electrode aperture and plasma aperture. The electrode rings increase the energy of the ions to a selected energy in stages in passing between successive pairs of the electrodes by application of an accelerating voltage to the successive pairs of accelerator electrodes. A target disposed co-axially around the plurality of electrodes receives the beam of accelerated ions, producing gamma rays.

  1. Cystic lesions accompanying extra-axial tumours

    NARCIS (Netherlands)

    Lohle, PNM; Wurzer, HAL; Seelen, PJ; Kingma, LM; Go, KG

    We examined the mechanism of cyst formation in extra-axial tumours in the central nervous system (CNS). Cyst fluid, cerebrospinal fluid (CSF) and blood plasma were analysed in eight patients with nine peritumoral cysts: four with meningiomas, two with intracranial and two spinal intradural

  2. The design of axial shaftless pump

    Science.gov (United States)

    Schmirler, Michal; Netrebska, Hana

    The axial shaftless pump with a rotary casing has been proposed. The pump is unique in its small space requirements and the ability to draw a liquid with a high content of impurities and fibers. Modern motor with an external commutation was used to propel the pump rotor. The pump can be used for both pumping of liquids and marine propulsion.

  3. The design of axial shaftless pump

    Directory of Open Access Journals (Sweden)

    Schmirler Michal

    2017-01-01

    Full Text Available The axial shaftless pump with a rotary casing has been proposed. The pump is unique in its small space requirements and the ability to draw a liquid with a high content of impurities and fibers. Modern motor with an external commutation was used to propel the pump rotor. The pump can be used for both pumping of liquids and marine propulsion.

  4. VERY SLOW SPEED AXIAL MOTION RELUCTANCE MOTOR

    African Journals Online (AJOL)

    Dr Obe

    1984-09-01

    Sep 1, 1984 ... VERY SLOW SPEED AXIAL MOTION RELUCTANCE MOTOR by. L. A. Agu. Electrical Engineering Department. University of Nigeria, Nsukka. ABSTRACT. This paper presents the scheme for a very slow speed linear machine which uses conventional laminations and with which speeds of the same low.

  5. Management of Sub-axial Cervical Spine Injuries

    Science.gov (United States)

    Zaveri, Gautam; Das, Gurdip

    2017-01-01

    Sub-axial cervical spine injuries are commonly seen in patients with blunt trauma. They may be associated with spinal cord injury resulting in tetraplegia and severe permanent disability. Immobilization of the neck, maintenance of blood pressure and oxygenation, rapid clinical and radiological assessment of all injuries, and realignment of the spinal column are the key steps in the emergency management of these injuries. The role of intravenous methylprednisolone administration in acute spinal cord injuries remains controversial. The definitive management of these injuries is based upon recognition of the fracture pattern, assessment of the degree of instability, the presence or absence of neurologic deficit, and other patient related factors that may influence the outcome. Nonoperative treatment comprises of some form of external immobilization for 8 to 12 weeks, followed by imaging to assess fracture healing, and to rule out instability. The goals of surgery are realignment of the vertebral column, decompression of the neural elements and instrumented stabilization. PMID:29200479

  6. Application Feasibility Evaluation on a Co-axial Piping for Intermediate Heat Transport System

    Energy Technology Data Exchange (ETDEWEB)

    Park, Chang Gyu; Kim, Jong Bum; Lee, Jae Han

    2008-02-15

    The IHX in a pool-type SFR system transfers heat from the primary high temperature sodium to the intermediate cold temperature sodium. The upper internal structure of IHX is a co-axial piping to form the flow path of both the secondary high temperature and low temperature sodium. The co-axial piping of the IHX consists of a central downcomer and riser for incoming and outgoing intermediate sodium, respectively. The IHXs of a pool-type SFR are supported at the top surface of the reactor head which is low temperature condition relatively. Therefore, the temperature distribution of a co-axial piping including the IHX support structure may induce the complicated severe thermal stress distribution. In this study, the structural features of a co-axial piping are investigated and the advanced conceptual design to accommodate the IHTS piping expansion and the severe thermal stress is proposed. It is shown through the structural analysis that the advanced design concept is effective to reduce the thermal stress and the preliminary structural integrity by considering the refuel cycle is assured.

  7. CONTRIBUTION OF AXIAL MOTOR IMPAIRMENT TO PHYSICAL INACTIVITY IN PARKINSON'S DISEASE

    Science.gov (United States)

    Bryant, Mon S; Hou, Jyhgong Gabriel; Collins, Robert L; Protas, Elizabeth J

    2015-01-01

    Objective To investigate the relationships between motor symptoms of Parkinson’s disease (PD) and activity limitations in persons with PD. Design/Methods Cross-sectional study of persons with mild to moderate PD (N=90). Associations among axial motor features, limb motor signs, the Physical Activity Scale for Elders (PASE), the ability to perform Activities of Daily Living (ADL) and level of ADL dependency were studied. A composite score of axial motor features included the following UPDRS items: speech, rigidity of the neck, arising from chair, posture, gait and postural stability. A composite score of limb motor signs included the following UPDRS items: tremor at rest of all extremities, action tremor, rigidity of all extremities, finger taps, hand movement, rapid alternating hand movements and foot tapping. Results Axial motor features of PD were significantly correlated with physical inactivity (pphysical inactivity. After controlling for age, gender, disease duration and comorbidity, axial motor features contributed significantly to physical inactivity, decreased ADL and increase in ADL dependency, whereas the limb motor signs did not. Conclusions Axial motor impairment contributed to physical inactivity and decreased ability to perform ADLs in persons with PD. PMID:26368837

  8. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head Computed tomography (CT) of the head uses special x-ray ... Head? What is CT Scanning of the Head? Computed tomography, more commonly known as a CT or CAT ...

  9. Head counts.

    Science.gov (United States)

    Wattenberg, B

    1994-08-24

    A fellow at the American Enterprise Institute remarked that population growth slowed from 1.73% to 1.57% during 1990 to 1994. In Eastern Europe alone population declined by 1 million in the past 4 years. Fertility decline is evident even in Africa and a rapid fertility transition has appeared in Iran. The data are based on figures recently generated by the UN and published in "World Population Prospects: 1994 revision." The projected medium fertility variant was 9.8 billion by 2050 and 10 billion in 2054. UN statisticians have reported that the real numbers are likely to be even higher despite their own reports of fertility decline. The UN believes that sustaining 2.1 children per woman at replacement level will not be allowed by countries. The more developed countries are now at or below replacement: Japan at 1.5, Korea at 1.7, Germany at 1.3, and Italians at 1.3. Large population numbers threaten stability and are related to famine, pollution, war, and animal and plant species decimation. The evidence from Rwanda and Bosnia is clear. A more desirable and realistic estimate should be 7-8 billion by 2050. World population in preparation for the International Conference on Population and Development is being publicized as a problem so that the UN and environmentalists can increase their funding and attain a high spot on the global agenda. The author's experience as part of the US delegation to the International Population Conference in Mexico City in 1984 led to the conclusion that these international policy conferences are really public relations events. Gloom and doom predictions are constantly being modified; for instance, what was the "coming ice age" is now "global warming." The world has survived thus far, while the numbers have been increasing. If the world does not prosper in the years ahead, it is unlikely to be due to too many people.

  10. Ventajas de los motores de flujo axial

    Directory of Open Access Journals (Sweden)

    Alberto M Basanta Otero

    2011-03-01

    Full Text Available Es importante conocer sobre una familia de motores que a diferencia de los convencionales o tradicionales no presentanun flujo rotatorio radial, denominados motores de flujo axial. Dichos motores presentan altos valores de par motriz abajas velocidades, una alta eficiencia y alta densidad de potencia. Este trabajo constituye un breve análisis dealgunos motores de la referencia bibliográfica.  Is important to know about a family of motors that at difference whit the traditional, don't have a rotator radial flux,called, axial flux motors. These motors have high torque for low speed, high efficiency and high power density. Thiswork is a brief analysis of several motors of the bibliographic references.

  11. Induced axial and lateral color surface contributions.

    Science.gov (United States)

    Berner, Andrea; Nobis, Thomas; Gross, Herbert

    2017-05-01

    Induced aberrations in general are higher-order aberrations caused by ray perturbations of lower order, picked up in the preceding optical system. Therefore, in the case of color aberrations, induced influences can already be observed at the second order. They are generated by the preexisting first-order axial and lateral color. The analysis of relevant designs surface by surface to identify performance dominating lenses is a key method for understanding and optimizing those systems. Hence, in this paper a formula for the surface contribution of axial and lateral color including second-order terms is derived and discussed differentiating between intrinsic and induced parts. It is also shown how this can be used to deduce a thick-lens contribution of the second order. All of the approaches are based on the Seidel concept, which characterizes any arbitrary optical system only by the paraxial marginal and chief ray of the primary wavelength.

  12. Axial flux permanent magnet brushless machines

    CERN Document Server

    Gieras, Jacek F; Kamper, Maarten J

    2008-01-01

    Axial Flux Permanent Magnet (AFPM) brushless machines are modern electrical machines with a lot of advantages over their conventional counterparts. They are being increasingly used in consumer electronics, public life, instrumentation and automation system, clinical engineering, industrial electromechanical drives, automobile manufacturing industry, electric and hybrid electric vehicles, marine vessels and toys. They are also used in more electric aircrafts and many other applications on larger scale. New applications have also emerged in distributed generation systems (wind turbine generators

  13. Cyclotron axial ion-beam-buncher system

    Energy Technology Data Exchange (ETDEWEB)

    Hamm, R.W.; Swenson, D.A.; Wangler, T.P.

    1982-02-11

    Adiabatic ion bunching is achieved in a cyclotron axial ion injection system through the incorporation of a radio frequency quadrupole system, which receives ions from an external ion source via an accelerate-decelerate system and a focusing einzel lens system, and which adiabatically bunches and then injects the ions into the median plane of a cyclotron via an electrostatic quadrupole system and an inflection mirror.

  14. Dynamic control of knee axial deformities

    OpenAIRE

    E. E. Malyshev; Pavlov, D. V.; S. V. Blinov

    2013-01-01

    The authors have evaluated the clinical examination of the patients with axial malalignments in the knee by the original method and device which was named varovalgometer. The measurements were conducted by tension of the cord through the spina iliaca anterior superior and the middle of the lower pole of patella. The deviation of the center of the ankle estimated by metal ruler which was positioned perpendicular to the lower leg axis on the level of the ankle joint line. The results of compari...

  15. Axial gravity, massless fermions and trace anomalies

    Science.gov (United States)

    Bonora, L.; Cvitan, M.; Prester, P. Dominis; Pereira, A. Duarte; Giaccari, S.; Štemberga, T.

    2017-08-01

    This article deals with two main topics. One is odd parity trace anomalies in Weyl fermion theories in a 4d curved background, the second is the introduction of axial gravity. The motivation for reconsidering the former is to clarify the theoretical background underlying the approach and complete the calculation of the anomaly. The reference is in particular to the difference between Weyl and massless Majorana fermions and to the possible contributions from tadpole and seagull terms in the Feynman diagram approach. A first, basic, result of this paper is that a more thorough treatment, taking account of such additional terms and using dimensional regularization, confirms the earlier result. The introduction of an axial symmetric tensor besides the usual gravitational metric is instrumental to a different derivation of the same result using Dirac fermions, which are coupled not only to the usual metric but also to the additional axial tensor. The action of Majorana and Weyl fermions can be obtained in two different limits of such a general configuration. The results obtained in this way confirm the previously obtained ones.

  16. Enriched axial anomaly in Weyl materials

    Science.gov (United States)

    Raines, Zachary M.; Galitski, Victor M.

    2017-10-01

    While quantum anomalies are often associated with the breaking of a classical symmetry in the quantum theory, their anomalous contributions to observables remain distinct and well defined even when the symmetry is broken from the outset. This paper explores such anomalous contributions to the current, originating from the axial anomaly in a Weyl semimetal, and in the presence of a generic Weyl node-mixing term. We find that apart from the familiar anomalous divergence of the axial current proportional to a product of electric and magnetic fields, there is another anomalous term proportional to a product of the electric field and the orientation of a spin-dependent node-mixing vector. We obtain this result both by a quantum field-theoretic analysis of an effective Weyl action and solving an explicit lattice model. The extended spin-mixing mass terms, and the enriched axial anomaly they entail, could arise as mean-field or proximity-induced order parameters in spin-density-wave phases in Weyl semimetals or be generated dynamically within a Floquet theory.

  17. Biomechanical properties of axially myopic cornea.

    Science.gov (United States)

    Altan, Cigdem; Demirel, Berna; Azman, Engin; Satana, Banu; Bozkurt, Ercüment; Demirok, Ahmet; Yilmaz, Omer Faruk

    2012-01-01

    To investigate biomechanical parameters of the cornea measured with ocular response analyzer (ORA) in myopic eyes with high axial length and the relationship between these parameters and axial length (AL). A total of 165 eyes of 165 consecutive patients were included. Eyes with AL greater than 26 mm were named group 1 and eyes with AL shorter than 26 mm were named group 2. Axial length and keratometric values were measured by intraocular lens (IOL) Master optical biometry. Metrics of corneal biomechanical properties, including corneal hysteresis (CH) and corneal resistance factor (CRF), were measured with the ORA. The ORA also determined the values of intraocular pressure (IOPg) and corneal compensated IOP (IOPcc). The mean age of total subjects was 43.0 ± 15.6 years. Eighty-three eyes were included in group 1; 82 eyes were included in group 2. The CH and CRF of group 1 were significantly lower than group 2. The IOPcc was significantly higher in group 1 than group 2. When group 1 and group 2 were combined for analysis, CH was negatively correlated with age. Both CH and CRF were significantly correlated with SE. However, CH and CRF were negatively correlated with AL. Also, there was significant correlation between AL and IOPcc (pbiomechanical properties of the cornea change with elongation of the eye and this may have an impact on IOP measurement.

  18. Dynamic control of knee axial deformities

    Directory of Open Access Journals (Sweden)

    E. E. Malyshev

    2013-01-01

    Full Text Available The authors have evaluated the clinical examination of the patients with axial malalignments in the knee by the original method and device which was named varovalgometer. The measurements were conducted by tension of the cord through the spina iliaca anterior superior and the middle of the lower pole of patella. The deviation of the center of the ankle estimated by metal ruler which was positioned perpendicular to the lower leg axis on the level of the ankle joint line. The results of comparison of our method and computer navigation in 53 patients during the TKA show no statistically significant varieties but they differ by average 5° of valgus in clinical examination in comparison with mechanical axis which was identified by computer navigation. The dynamic control of axial malalignment can be used in clinical practice for estimation of the results of treatment of pathology with axial deformities in the knee; for the control of reduction and secondary displacement of the fractures around the knee; for assessment of instability; in planning of correctional osteotomies and intraoperative control of deformity correction; for estimation of Q angle in subluxation and recurrent dislocation of patella; in planning of TKA; during the growth of child it allows to assess the progression of deformity.

  19. Axial gravity, massless fermions and trace anomalies

    Energy Technology Data Exchange (ETDEWEB)

    Bonora, L. [International School for Advanced Studies (SISSA), Trieste (Italy); KEK, Tsukuba (Japan). KEK Theory Center; INFN, Sezione di Trieste (Italy); Cvitan, M.; Giaccari, S.; Stemberga, T. [Zagreb Univ. (Croatia). Dept. of Physics; Prester, P.D. [Rijeka Univ. (Croatia). Dept. of Physics; Pereira, A.D. [UERJ-Univ. Estadual do Rio de Janeiro (Brazil). Dept. de Fisica Teorica; UFF-Univ. Federal Fluminense, Niteroi (Brazil). Inst. de Fisica

    2017-08-15

    This article deals with two main topics. One is odd parity trace anomalies in Weyl fermion theories in a 4d curved background, the second is the introduction of axial gravity. The motivation for reconsidering the former is to clarify the theoretical background underlying the approach and complete the calculation of the anomaly. The reference is in particular to the difference between Weyl and massless Majorana fermions and to the possible contributions from tadpole and seagull terms in the Feynman diagram approach. A first, basic, result of this paper is that a more thorough treatment, taking account of such additional terms and using dimensional regularization, confirms the earlier result. The introduction of an axial symmetric tensor besides the usual gravitational metric is instrumental to a different derivation of the same result using Dirac fermions, which are coupled not only to the usual metric but also to the additional axial tensor. The action of Majorana and Weyl fermions can be obtained in two different limits of such a general configuration. The results obtained in this way confirm the previously obtained ones. (orig.)

  20. Might axial myofascial properties and biomechanical mechanisms be relevant to ankylosing spondylitis and axial spondyloarthritis?

    Science.gov (United States)

    Masi, Alfonse T

    2014-01-01

    Ankylosing spondylitis and axial spondyloarthropathy have characteristic age- and sex-specific onset patterns, typical entheseal lesions, and marked heritability, but the integrative mechanisms causing the pathophysiological and structural alterations remain largely undefined. Myofascial tissues are integrated in the body into webs and networks which permit transmission of passive and active tensional forces that provide stabilizing support and help to control movements. Axial myofascial hypertonicity was hypothesized as a potential excessive polymorphic trait which could contribute to chronic biomechanical overloading and exaggerated stresses at entheseal sites. Such a mechanism may help to integrate many of the characteristic host, pathological, and structural features of ankylosing spondylitis and axial spondyloarthritis. Biomechanical stress and strain were recently documented to correlate with peripheral entheseal inflammation and new bone formation in a murine model of spondyloarthritis. Ankylosing spondylitis has traditionally been classified by the modified New York criteria, which require the presence of definite radiographic sacroiliac joint lesions. New classification criteria for axial spondyloarthritis now include patients who do not fulfill the modified New York criteria. The male-to-female sex ratios clearly differed between the two patient categories - 2:1 or 3:1 in ankylosing spondylitis and 1:1 in non-radiographic axial spondyloarthritis - and this suggests a spectral concept of disease and, among females, milder structural alterations. Magnetic resonance imaging of active and chronic lesions in ankylosing spondylitis and axial spondyloarthritis reveals complex patterns, usually interpreted as inflammatory reactions, but shows similarities to acute degenerative disc disease, which attributed to edema formation following mechanical stresses and micro-damage. A basic question is whether mechanically induced microinjury and immunologically mediated

  1. Intrinsic carpal ligaments on MR and multidetector CT arthrography: comparison of axial and axial oblique planes

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ryan K.L.; Griffith, James F.; Ng, Alex W.H.; Law, Eric K.C. [The Chinese University of Hong Kong, Department of Imaging and Interventional Radiology, Prince Of Wales Hospital, Hong Kong (China); Tse, W.L.; Wong, Clara W.Y.; Ho, P.C. [The Chinese University of Hong Kong, Department of Orthopedics and Traumatology, Prince Of Wales Hospital, Hong Kong (China)

    2017-03-15

    To compare axial and oblique axial planes on MR arthrography (MRA) and multidetector CT arthrography (CTA) to evaluate dorsal and volar parts of scapholunate (SLIL) and lunotriquetral interosseous (LTIL) ligaments. Nine cadaveric wrists of five male subjects were studied. The visibility of dorsal and volar parts of the SLIL and LTIL was graded semi-quantitatively (good, intermediate, poor) on MRA and CTA. The presence of a ligament tear was determined on arthrosocopy and sensitivity, specificity and accuracy of tear detection were calculated. Oblique axial imaging was particularly useful for delineating dorsal and volar parts of the LTIL on MRA with overall 'good' visibility increased from 11 % to 78 %. The accuracy of MRA and CTA in revealing SLIL and LTIL tear was higher using the oblique axial plane. The overall accuracy for detecting SLIL tear on CTA improved from 94 % to 100 % and from 89 % to 94 % on MRA; the overall accuracy of detecting LTIL tear on CTA improved from 89 % to 100 % and from 72 % to 89 % on MRA Oblique axial imaging during CT and MR arthrography improves detection of tears in the dorsal and volar parts of both SLIL and LTIL. (orig.)

  2. Axial loading with hyperflexion injury to the atlas resulting in crushed lateral masses.

    Science.gov (United States)

    Sasaka, Kaoru K; Decker, Gerald T; El-Khoury, Georges Y

    2006-09-01

    A 40-year-old man was involved in an ATV accident, in which he landed on the top of his head. There was no neurological deficit. A plain radiograph showed prevertebral soft tissue swelling at the atlas and axis level. Computed tomography (CT) demonstrated vertical fractures of the anterior aspects of both lateral masses of the atlas, extending to the junction of the lateral mass with the anterior arch bilaterally. There was no lateral offset of the lateral masses. The mechanism of injury is believed to be axial loading along with hyperflexion.

  3. Atomistic simulations on the axial nanowelding configuration and contact behavior between Ag nanowire and single-walled carbon nanotubes

    Energy Technology Data Exchange (ETDEWEB)

    Cui, Jianlei, E-mail: cjlxjtu@mail.xjtu.edu.cn; Zhang, Jianwei [Xi’an Jiaotong University, State Key Laboratory for Manufacturing Systems Engineering (China); He, Xiaoqiao, E-mail: bcxqhe@cityu.edu.hk [City University of Hong Kong, Department of Architecture and Civil Engineering (Hong Kong); Yang, Xinjun [Fudan University, State Key Laboratory of Surface Physics and Department of Physics (China); Mei, Xuesong; Wang, Wenjun; Jiang, Gedong; Wang, Kedian [Xi’an Jiaotong University, State Key Laboratory for Manufacturing Systems Engineering (China); Yang, Lijun; Xie, Hui [Harbin Institute of Technology, State Key Laboratory of Robotics and Systems (China)

    2017-03-15

    As for the interesting new building blocks, the Ag nanowires (AgNWs) and single-walled carbon nanotubes (SWNTs) as the interesting new building blocks are viewed as the promising candidates for the next-generation interconnects due to their most remarkable electrical, thermal, optical, mechanical, and other properties. The axial nanowelding of head-to-head style and side-to-side style is relatively simulated with the molecular dynamics method. As for the head-to-head structural style, SWNTs will move toward the AgNWs and contact with the head of AgNWs. And, the part of the Ag nanowire may be subsequently encapsulated in SWNT with the core-filling Ag atom chain as the final atomic contact configuration during nanowelding, which is related to the nanowelding temperature. When the SWNTs and AgNWs are arranged by the side-to-side contact style, the SWNTs will move along the SWNT surface and may eventually catch up with the AgNW being neck and neck. Aiming at the final axial atomic configurations and the contact behavior during nanowelding process, the related dominant mechanism is revealed in this paper.

  4. Atomistic simulations on the axial nanowelding configuration and contact behavior between Ag nanowire and single-walled carbon nanotubes

    Science.gov (United States)

    Cui, Jianlei; Zhang, Jianwei; He, Xiaoqiao; Yang, Xinjun; Mei, Xuesong; Wang, Wenjun; Jiang, Gedong; Wang, Kedian; Yang, Lijun; Xie, Hui

    2017-03-01

    As for the interesting new building blocks, the Ag nanowires (AgNWs) and single-walled carbon nanotubes (SWNTs) as the interesting new building blocks are viewed as the promising candidates for the next-generation interconnects due to their most remarkable electrical, thermal, optical, mechanical, and other properties. The axial nanowelding of head-to-head style and side-to-side style is relatively simulated with the molecular dynamics method. As for the head-to-head structural style, SWNTs will move toward the AgNWs and contact with the head of AgNWs. And, the part of the Ag nanowire may be subsequently encapsulated in SWNT with the core-filling Ag atom chain as the final atomic contact configuration during nanowelding, which is related to the nanowelding temperature. When the SWNTs and AgNWs are arranged by the side-to-side contact style, the SWNTs will move along the SWNT surface and may eventually catch up with the AgNW being neck and neck. Aiming at the final axial atomic configurations and the contact behavior during nanowelding process, the related dominant mechanism is revealed in this paper.

  5. Axial flow heat exchanger devices and methods for heat transfer using axial flow devices

    Science.gov (United States)

    Koplow, Jeffrey P.

    2016-02-16

    Systems and methods described herein are directed to rotary heat exchangers configured to transfer heat to a heat transfer medium flowing in substantially axial direction within the heat exchangers. Exemplary heat exchangers include a heat conducting structure which is configured to be in thermal contact with a thermal load or a thermal sink, and a heat transfer structure rotatably coupled to the heat conducting structure to form a gap region between the heat conducting structure and the heat transfer structure, the heat transfer structure being configured to rotate during operation of the device. In example devices heat may be transferred across the gap region from a heated axial flow of the heat transfer medium to a cool stationary heat conducting structure, or from a heated stationary conducting structure to a cool axial flow of the heat transfer medium.

  6. Iterative autofocusing strategy for axial distance error correction in ptychography

    Science.gov (United States)

    Dou, Jiantai; Gao, Zhishan; Ma, Jun; Yuan, Caojin; Yang, Zhongming; Wang, Lei

    2017-11-01

    The axial distance error can degrade the quality and resolution of the image reconstructed by ptychography. An iterative autofocusing method is proposed to correct the axial distance error. Based on the Fresnel integral theory, an axial distance error model is established to present the effect of the axial distance error on the recovered image. The information of the retrieved image is chosen to calculate the axial distance by autofocusing algorithm. The calculated distance is used to replace the axial distance and applied for the image reconstruction. When the calculated axial distance reaches the convergence, the distance can be accurately obtained that can be used to enhance the quality and resolution of the reconstructed image. Simulations and experiments have been conducted to verify the performance of the proposed method.

  7. Head injury - first aid

    Science.gov (United States)

    ... medlineplus.gov/ency/article/000028.htm Head injury - first aid To use the sharing features on this page, ... a concussion can range from mild to severe. First Aid Learning to recognize a serious head injury and ...

  8. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... the head is typically used to detect: bleeding, brain injury and skull fractures in patients with head injuries. ... hard time staying still, are claustrophobic or have chronic pain, you may find a CT exam to ...

  9. Head and face reconstruction

    Science.gov (United States)

    ... medlineplus.gov/ency/article/002980.htm Head and face reconstruction To use the sharing features on this page, please enable JavaScript. Head and face reconstruction is surgery to repair or reshape deformities ...

  10. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... the limitations of CT Scanning of the Head? What is CT Scanning of the Head? Computed tomography, ... than regular radiographs (x-rays). top of page What are some common uses of the procedure? CT ...

  11. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... for Brain Tumors Radiation Therapy for Head and Neck Cancer Others American Stroke Association National Stroke Association ... Computer Tomography (CT) Safety During Pregnancy Head and Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine ...

  12. Newborn head molding

    Science.gov (United States)

    Newborn cranial deformation; Molding of the newborn's head; Neonatal care - head molding ... The bones of a newborn baby's skull are soft and flexible, with gaps between the plates of bone. The spaces between the bony plates of ...

  13. In-shoe plantar tri-axial stress profiles during maximum-effort cutting maneuvers.

    Science.gov (United States)

    Cong, Yan; Lam, Wing Kai; Cheung, Jason Tak-Man; Zhang, Ming

    2014-12-18

    Soft tissue injuries, such as anterior cruciate ligament rupture, ankle sprain and foot skin problems, frequently occur during cutting maneuvers. These injuries are often regarded as associated with abnormal joint torque and interfacial friction caused by excessive external and in-shoe shear forces. This study simultaneously investigated the dynamic in-shoe localized plantar pressure and shear stress during lateral shuffling and 45° sidestep cutting maneuvers. Tri-axial force transducers were affixed at the first and second metatarsal heads, lateral forefoot, and heel regions in the midsole of a basketball shoe. Seventeen basketball players executed both cutting maneuvers with maximum efforts. Lateral shuffling cutting had a larger mediolateral braking force than 45° sidestep cutting. This large braking force was concentrated at the first metatarsal head, as indicated by its maximum medial shear stress (312.2 ± 157.0 kPa). During propulsion phase, peak shear stress occurred at the second metatarsal head (271.3 ± 124.3 kPa). Compared with lateral shuffling cutting, 45° sidestep cutting produced larger peak propulsion shear stress (463.0 ± 272.6 kPa) but smaller peak braking shear stress (184.8 ± 181.7 kPa), of which both were found at the first metatarsal head. During both cutting maneuvers, maximum medial and posterior shear stress occurred at the first metatarsal head, whereas maximum pressure occurred at the second metatarsal head. The first and second metatarsal heads sustained relatively high pressure and shear stress and were expected to be susceptible to plantar tissue discomfort or injury. Due to different stress distribution, distinct pressure and shear cushioning mechanisms in basketball footwear might be considered over different foot regions. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Aerodynamics of Advanced Axial-Flow Turbomachinery.

    Science.gov (United States)

    1980-11-30

    cementing in place short segments of lb ga. (1.2 mm I.D.) hypodermic tubing in drillud holes carefully aligned normal to the sidewall profile at the...PRESSURE I REFERENCE SCANPREF I I SYSTEM 0YTE NECKED- PRF NEEDLE VALVE PE PRRSSUE TRANSDUCER AMPLIF IER] POSITIONER TEMPERATURES I STO BE READ I...Compressors. U.S. NASA SP-36. 1965. 23. Hearsey, R. M. A Revised Computer Program for Axial Compressor Design Volume 1: Theory , Descriptions and User’s

  15. Ankylosing Spondylitis versus Nonradiographic Axial Spondyloarthritis

    DEFF Research Database (Denmark)

    Glintborg, Bente; Sørensen, Inge J; Østergaard, Mikkel

    2017-01-01

    OBJECTIVE: To compare baseline disease activity and treatment effectiveness in biologic-naive patients with nonradiographic axial spondyloarthritis (nr-axSpA) and ankylosing spondylitis (AS) who initiate tumor necrosis factor inhibitor (TNFi) treatment and to study the role of potential confounders....../disease duration/TNFi-type/smoking/baseline disease activity) on TNFi adherence and response [e.g., Bath Ankylosing Spondylitis Activity Index (BASDAI) 50%/20 mm]. RESULTS: The study included 1250 TNFi-naive patients with axSpA (29% nr-axSpA, 50% AS, 21% lacked radiographs of sacroiliac joints). Patients...

  16. Aerodynamic Modelling and Optimization of Axial Fans

    DEFF Research Database (Denmark)

    Sørensen, Dan Nørtoft

    A numerically efficient mathematical model for the aerodynamics oflow speed axial fans of the arbitrary vortex flow type has been developed.The model is based on a blade-element principle, whereby therotor is divided into a number of annular streamtubes.For each of these streamtubes relations...... and integrated propertiesshow that the computed results agree well with the measurements.Integrating a rotor-only version of the aerodynamic modelwith an algorithm for numerical designoptimization, enables the finding of an optimum fan rotor.The angular velocity of the rotor, the hub radius and the spanwise...

  17. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... limitations of CT Scanning of the Head? What is CT Scanning of the Head? Computed tomography, more commonly known as a ... top of page What are some common uses of the procedure? CT scanning of the head is ...

  18. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Computed tomography (CT) of the head uses special x-ray equipment to help assess head injuries, severe headaches, dizziness, and other symptoms of ... content. Related Articles and Media Radiation Dose in X-Ray and CT ... Perfusion of the Head CT Angiography (CTA) Stroke Brain Tumors Computer Tomography ( ...

  19. The value of a rapid contrast-enhanced angio-MRI protocol in the detection of head and neck paragangliomas in SDHx mutations carriers: a retrospective study on behalf of the PGL.EVA investigators*

    Energy Technology Data Exchange (ETDEWEB)

    Gravel, Guillaume; Hernigou, Anne [Hopital Europeen Georges Pompidou, Assistance Publique-Hopitaux de Paris, Service de Radiologie, Paris (France); Niccoli, Patricia [Centre Hospitalier Universitaire la Timone, Assistance Publique-Hopitaux de Marseille, Service d' Endocrinologie, Diabete et Maladies Metaboliques, Marseille (France); Rohmer, Vincent [Centre Hospitalier Universitaire d' Angers, Service d' Endocrinologie, Diabetologie, Nutrition, Angers (France); LUNAM Universite, INSERM, U1063, Angers (France); Moulin, Guy [Centre Hospitalier Universitaire la Timone, Assistance Publique-Hopitaux de Marseille, Service de Radiologie, Marseille (France); Borson-Chazot, Francoise [Federation d' Endocrinologie, Hospices civils de Lyon, Groupement Hospitalier Est, Lyon (France); Universite de Lyon, Faculte de Medecine Lyon-Est, Lyon (France); Cancer Research Center of Lyon, INSERM UMR1052, UMR CNRS 5286, Lyon (France); Rousset, Pascal [Hospices civils de Lyon, Groupement Hospitalier Est, Service de Radiologie, Lyon (France); Pasco-Papon, Anne [Centre Hospitalier Universitaire d' Angers, Service de Radiologie, Angers (France); Marcus, Claude [Centre Hospitalo-Universitaire de Reims, Service de Radiologie, Reims (France); Dubrulle, Frederique [Centre Hospitalo-Universitaire de Lille, Service de Radiologie, Lille (France); Gouya, Herve [Hopital Cochin, Assistance Publique-Hopitaux de Paris, Service de Radiologie, Paris (France); Bidault, Francois [Institut Gustave Roussy, Service de Radiologie, Villejuif (France); Dupas, Benoit [Centre Hospitalo-Universitaire de Nantes, Service de Radiologie, Nantes (France); Gabrillargues, Jean [Centre Hospitalo-Universitaire de Clermont-Ferrand, Service de Neuroradiologie, Clermont Ferrand (France); Caumont-Prim, Aurore [Unite d' Epidemiologie et de Recherche Clinique, Assistance Publique-Hopitaux de Paris, Hopital Europeen Georges Pompidou, Paris (France); Centre d' investigation Epidemiologique 4, INSERM, Paris (France); Gimenez-Roqueplo, Anne-Paule [Hopital Europeen Georges Pompidou, Assistance Publique-Hopitaux de Paris, Service de Genetique, Paris (France); Paris Cardiovascular Research Center, INSERM, UMR970, Paris (France); Universite Paris Descartes, Sorbonne Paris Cite, Faculte de Medecine, Paris (France); Halimi, Philippe [Hopital Europeen Georges Pompidou, Assistance Publique-Hopitaux de Paris, Service de Radiologie, Paris (France); Universite Paris Descartes, Sorbonne Paris Cite, Faculte de Medecine, Paris (France)

    2016-06-15

    To assess the performance of a simplified MRI protocol consisting of a contrast-enhanced three-dimensional MR angiography (CE-MRA) in association with a post-contrast T1-weighted sequence (T1WIV) for the detection of HNPGLs in SDHx mutation carriers. This retrospective sub-study is based on the multicenter PGL.EVA cohort, which prospectively enrolled SDHx mutation carriers from 2005 to 2009; 157 index cases or relatives were included. CE-MRA and the T1WIV images were read solely with knowledge of the clinical data but blind to the diagnosis. Sensitivity, specificity and likelihood ratios for the simplified MRI protocol were compared to the full MRI protocol reading results and to the gold standard status obtained through the consensus of an expert committee. The sensitivity and specificity of the readings of the simplified MRI protocol were, respectively, 88.7 % (95 % CI = 78.1-95.3) and 93.7 % (95 % CI = 86.8-97.7) versus 80.7 % (95 % CI = 68.6-89.6) and 94.7 % (95 % CI = 88.1-98.3) for the readings of the full MRI protocol. The simplified post-contrast MRI with shorter duration (5 to 10 minutes) showed no performance difference compared to the lengthy standard full MRI and can be proposed for the detection of head and neck paragangliomas (HNPGLs) in SDHx mutation carriers. (orig.)

  20. Axial tomography in live cell laser microscopy

    Science.gov (United States)

    Richter, Verena; Bruns, Sarah; Bruns, Thomas; Weber, Petra; Wagner, Michael; Cremer, Christoph; Schneckenburger, Herbert

    2017-09-01

    Single cell microscopy in a three-dimensional (3-D) environment is reported. Cells are grown in an agarose culture gel, located within microcapillaries and observed from different sides after adaptation of an innovative device for sample rotation. Thus, z-stacks can be recorded by confocal microscopy in different directions and used for illustration in 3-D. This gives additional information, since cells or organelles that appear superimposed in one direction, may be well resolved in another one. The method is tested and validated with single cells expressing a membrane or a mitochondrially associated green fluorescent protein, or cells accumulating fluorescent quantum dots. In addition, axial tomography supports measurements of cellular uptake and distribution of the anticancer drug doxorubicin in the nucleus (2 to 6 h after incubation) or the cytoplasm (24 h). This paper discusses that upon cell rotation an enhanced optical resolution in lateral direction compared to axial direction can be utilized to obtain an improved effective 3-D resolution, which represents an important step toward super-resolution microscopy of living cells.

  1. Multi-Axial Simulation Table (MAST)

    Data.gov (United States)

    Federal Laboratory Consortium — The MAST delivers an extensive array of testing applications providing rapid, flexible and reliable analysis for ground vehicle components and subassemblies. Using...

  2. Magnetic Resonance Imaging (MRI) -- Head

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Head Magnetic resonance imaging (MRI) of the head ... limitations of MRI of the Head? What is MRI of the Head? Magnetic resonance imaging (MRI) is ...

  3. Primary aberration coefficients for axial gradient-index lenses

    Science.gov (United States)

    Bociort, Florian

    1999-08-01

    As for homogeneous lenses, for axial gradients the analysis of the Seidel and chromatic aberration coefficients can be very useful in lens design. However, at present few commercial optical design programs list the Seidel aberrations of GRIN lenses and none of them lists the chromatic aberrations. In order to facilitate the computer implementation of the chromatic aberrations of axial GRIN lenses a new mathematical derivation for the axial and lateral color coefficients is presented. Also, new qualitative insight into the properties of axial GRIN lenses is obtained by introducing the thin-lens approximation in the aberration expressions. Within the domain of validity of this approximation, the primary aberrations of an axial GRIN lens are equivalent to those of a pair of homogeneous aspherical lens in contact, having a common plane surface and having refractive indices and Abbe numbers equal to the corresponding axial GRIN values at the two end surfaces.

  4. An appraisal of golimumab in the treatment of severe, active nonradiographic axial spondyloarthritis

    Directory of Open Access Journals (Sweden)

    Paccou J

    2016-07-01

    Full Text Available Julien Paccou, René-Marc Flipo Department of Rheumatology, Lille University Hospital, Lille, France Abstract: Golimumab (Simponi® is a fully human tumor necrosis factor α inhibitor (TNFi antibody administered subcutaneously. In the European Union, golimumab is indicated for the treatment of adults with severe, active axial spondyloarthritis (axSpA, which includes both ankylosing spondylitis (AS and nonradiographic axSpA (nr-axSpA. In the US, it is indicated for the treatment of adults with active AS only. This article reviews the efficacy and tolerability of golimumab in nr-axSpA patients compared to other TNFi agents (adalimumab, infliximab, etanercept, and certolizumab pegol. In one ongoing, well-designed controlled study (GO-AHEAD, data at 16 weeks showed that treatment with golimumab (50 mg every 4 weeks was effective in improving the clinical signs and symptoms of disease in nr-axSpA patients. In addition, 16 weeks of treatment with golimumab reduced inflammation in the sacroiliac joints and spine in patients with nr-axSpA. Moreover, objective evidence of active inflammation at baseline, such as a positive magnetic resonance imaging scan and/or an elevated CRP level, was a good predictor of treatment response to golimumab. Golimumab was generally well tolerated in this study, with a tolerability profile consistent with that seen in previous clinical trials for other indications. Although additional long-term data are needed, current evidence indicates that golimumab is an effective option for the treatment of nr-axSpA. However, in the absence of comparative head-to-head trials, there is no recommended hierarchy for the first prescription of a TNFi agent for the treatment of either nr-axSpA or AS. Keywords: axial spondyloarthritis, nonradiographic axial spondyloarthritis, ankylosing spondylitis, golimumab, tumor necrosis factor α inhibitor, therapy

  5. Measuring Earth’s axial tilt with a telescope

    Science.gov (United States)

    Suat Isildak, R.; Asuman Küçüközer, H.; Isik, Hakan

    2017-05-01

    In this study, a method to measure the Earth’s axial tilt is attempted by using a telescope. As a principal instrument, telescopes in astronomy courses are mostly to verify the astronomical objects in sky and not to make sense of astronomical events such as seasonal changes which is explained by the Earth’s axial tilt. This study outlines telescopic measurements to calculate the axial tilt at winter solstice.

  6. Head-to-toe whole-body MRI in psoriatic arthritis, axial spondyloarthritis and healthy subjects

    DEFF Research Database (Denmark)

    Poggenborg, René Panduro; Pedersen, Susanne Juhl; Eshed, Iris

    2015-01-01

    OBJECTIVES: By whole-body MRI (WBMRI), we aimed to examine the frequency and distribution of inflammatory and structural lesions in PsA patients, SpA patients and healthy subjects (HSs), to introduce global WBMRI inflammation/damage scores, and to assess WBMRI's reproducibility and correlation...... of inflammation and structural damage were constructed, and WBMRI findings were compared with clinical measures and convMRI (SpA/HS: spine and SI joints; PsA/HS: hand). RESULTS: The readability (92-100%) and reproducibility (intrareader intraclass correlation coefficient: 0.62-1.0) were high in spine/SI joint......-15]} and SpA [8 (IQR 2-14)] than in HSs [2.5 (IQR 1-4.5)], both P structural damage scores (erosion, fat infiltration and ankylosis) were higher in SpA [7 (IQR 3-12)] than HSs [1.5 (IQR 0-4.5)], P = 0.012. Correlations between WBMRI and convMRI spine and SI joint scores were ρ = 0...

  7. Energy Dissipation in Sandwich Structures During Axial Compression

    DEFF Research Database (Denmark)

    Urban, Jesper

    2002-01-01

    The purpose of this paper is to investigate the energy dissipation in sandwich structures during axial crushing. Axial crushing tests on six sandwich elements are described. The sandwich elements consist of a polyurethane core and E-glass/Polyester skin. The elements compare to full-scale structu......The purpose of this paper is to investigate the energy dissipation in sandwich structures during axial crushing. Axial crushing tests on six sandwich elements are described. The sandwich elements consist of a polyurethane core and E-glass/Polyester skin. The elements compare to full...

  8. Inertial fusion by magnetically transmitted axial cumulation

    Energy Technology Data Exchange (ETDEWEB)

    Eliezer, S.; Martinez-Val, J.; Piera, M. [Institute of Nuclear Fusion, Madrid (Spain); Vorobeichik, I.; Henis, Z. [Soreq Nuclear Research Centre, (Israel); Piera, M. [ETSII, UNED, Madrid (Spain)

    2000-07-01

    An analytical and numerical study is presented on the physics of Z-pinch implosions including magnetic fields to transmit the kinetic energy from the imploding shell to an axially placed filament. The shell kinetic energy can be built-up along a long pinch phase and a fraction of this energy could be transmitted to the filament in a much shorter interaction phase. Although initial estimates are very positive for energy cumulation in the filament, a deeper analysis shows that compressibility effects dominate the space-time evolution of the filament, and the energy cumulation level remains moderate. The scheme could be used to trigger fusion ignition in a direct-drive scenario (without radiation hohlraums) but driver specifications to get it are very demanding. (authors)

  9. Composite Axial Flow Propulsor for Small Aircraft

    Directory of Open Access Journals (Sweden)

    R. Poul

    2005-01-01

    Full Text Available This work focuses on the design of an axial flow ducted fan driven by a reciprocating engine. The solution minimizes the turbulization of the flow around the aircraft. The fan has a rotor - stator configuration. Due to the need for low weight of the fan, a carbon/epoxy composite material was chosen for the blades and the driving shaft.The fan is designed for optimal isentropic efficiency and free vortex flow. A stress analysis of the rotor blade was performed using the Finite Element  Method. The skin of the blade is calculated as a laminate and the foam core as a solid. A static and dynamic analysis were made. The RTM technology is compared with other technologies and is described in detail. 

  10. Axial coding and the grounded theory controversy.

    Science.gov (United States)

    Kendall, J

    1999-12-01

    The purpose of this article is to describe the similarities and differences between two approaches to grounded theory research: grounded theory as espoused by Glaser and grounded theory as espoused by Strauss and Corbin. The focus of the article is the controversy surrounding the use of axial coding. The author proposes a resolution to the controversy by suggesting that one does not need to view either approach as right or wrong; rather, the qualitative and grounded theory researcher can choose an approach, and that choice is based on the goal of the researcher's study. Examples of both approaches, from the author's research study on the experiences of living in a family with a child with attention deficit hyperactivity disorder (ADHD), are provided.

  11. Axially symmetric static sources of gravitational field

    Science.gov (United States)

    Hernandez-Pastora, J. L.; Herrera, L.; Martin, J.

    2016-12-01

    A general procedure to find static and axially symmetric, interior solutions to the Einstein equations is presented. All the so obtained solutions, verify the energy conditions for a wide range of values of the parameters, and match smoothly to some exterior solution of the Weyl family, thereby representing globally regular models describing non-spherical sources of gravitational field. In the spherically symmetric limit, all our models converge to the well known incompressible perfect fluid solution. The key stone of our approach is based on an ansatz allowing to define the interior metric in terms of the exterior metric functions evaluated at the boundary source. Some particular sources are obtained, and the physical variables of the energy-momentum tensor are calculated explicitly, as well as the geometry of the source in terms of the relativistic multipole moments. The total mass of different configurations is also calculated, it is shown to be equal to the monopole of the exterior solution.

  12. The Axial Part Phrase in Japanese

    Directory of Open Access Journals (Sweden)

    Kaori Takamine

    2007-01-01

    Full Text Available In this paper, I investigate the categorial status of spatial terms in locative/directional expressions in Japanese. I will show that a certain class of spatial terms have a distinct categorial status from both regular postpositions and nouns. On one hand, syntactic diagnostics such as doubling, coordination by to, and co-occurrence with demonstratives indicate that these spatial terms belong to a nominal category rather than to a postpositional category. On the other hand, the fact that these spatial terms are modified by range modifiers indicates that they are more similar to regular postpositions than to nouns. On the basis of these diagnostics, I will argue that spatial terms in Japanese need to be assigned a new category Axial Part Phrase which is proposed by Svenonius 2006.

  13. [The cornea in high axial myopia].

    Science.gov (United States)

    Touzeau, O; Gaujoux, T; Sandali, O; Allouch, C; Laroche, L; Borderie, V

    2014-06-01

    To compare corneal characteristics of eyes with high myopia with those of eyes with no spherical ametropia using Orbscan and ultrasonic pachymetry. Orbscan and ultrasonic pachymetry values were prospectively recorded in a study group of 105 patients with high myopia (i.e., axial length greater than 26mm in both eyes) and in a control group of 105 patients with no spherical ametropia (absolute value of spherical equivalent less than 1.25D regardless of cylinder value). Astigmatism data were expressed by rectangular coordinates in a dioptric plane. Axis was decomposed in 2 components (WTR/ATR and oblique) which were analyzed by Cos2axis and Sin2axis trigonometric functions. Enantiomorphism (mirror-image symmetry) between fellow eyes was quantified by a Euclidean distance for the location of the thinnest point and by the difference (in absolute value) between 180° and the sum of both axes for astigmatism. In the study group, the mean axial length and subjective spherical equivalent were, respectively, 27.82±2.14mm (26.00 to 34.06) and -9.00±3.46D (-4.71 to -19.82). The mean corneal astigmatism was +0.92D×91.3° in the study group and +0.65D×89.3° in the control group. The mean corneal cylinder was higher in the study group (1.44D versus 0.91D; Pspherical equivalent (r=-0.86; Pspherical ametropia, except for toricity. While the posterior segment elongates, development of high myopia appears not to affect corneal characteristics. Corneal toricity may be associated with evolution toward high myopia by perturbing mechanisms of emmetropization. Copyright © 2014. Published by Elsevier Masson SAS.

  14. Aerodynamic modelling and optimization of axial fans

    Energy Technology Data Exchange (ETDEWEB)

    Noertoft Soerensen, Dan

    1998-01-01

    A numerically efficient mathematical model for the aerodynamics of low speed axial fans of the arbitrary vortex flow type has been developed. The model is based on a blade-element principle, whereby the rotor is divided into a number of annular stream tubes. For each of these stream tubes relations for velocity, pressure and radial position are derived from the conservation laws for mass, tangential momentum and energy. The equations are solved using the Newton-Raphson methods, and solutions converged to machine accuracy are found at small computing costs. The model has been validated against published measurements on various fan configurations, comprising two rotor-only fan stages, a counter-rotating fan unit and a stator-rotor stator stage. Comparisons of local and integrated properties show that the computed results agree well with the measurements. Optimizations have been performed to maximize the mean value of fan efficiency in a design interval of flow rates, thus designing a fan which operates well over a range of different flow conditions. The optimization scheme was used to investigate the dependence of maximum efficiency on 1: the number of blades, 2: the width of the design interval and 3: the hub radius. The degree of freedom in the choice of design variable and constraints, combined with the design interval concept, provides a valuable design-tool for axial fans. To further investigate the use of design optimization, a model for the vortex shedding noise from the trailing edge of the blades has been incorporated into the optimization scheme. The noise emission from the blades was minimized in a flow rate design point. Optimizations were performed to investigate the dependence of the noise on 1: the number of blades, 2: a constraint imposed on efficiency and 3: the hub radius. The investigations showed, that a significant reduction of noise could be achieved, at the expense of a small reduction in fan efficiency. (EG) 66 refs.

  15. Numerical Investigation of the Influence of Blade Radial Gap Flow on Axial Blood Pump Performance.

    Science.gov (United States)

    Liu, Guang-Mao; Jin, Dong-Hai; Zhou, Jian-Ye; Zhang, Yan; Chen, Hai-Bo; Sun, Han-Song; Hu, Sheng-Shou; Gui, Xing-Min

    2018-01-05

    The gaps between the blades and the shroud (or hub) of an axial blood pump affect the hydraulics, efficiency, and hemolytic performance. These gaps are critical parameters when a blood pump is manufactured. To evaluate the influence of blade gaps on axial blood pump performance, the flow characteristics inside an axial blood pump with different radial blade gaps were numerically simulated and analyzed with special attention paid to the hydraulic characteristics, gap flow, hydraulic efficiency, and hemolysis index (HI). In vitro hydraulic testing and particle image velocimetry testing were conducted to verify the numerical results. The simulation results showed that the efficiency and pressure rise decreased when the gap increased. The efficiency of the axial blood pump at design point decreased from 37.1% to 27.1% and the pressure rise decreased from 127.4 to 71.2 mm Hg when the gap increased from 0.1 to 0.3 mm. Return and vortex flows were present in the outlet guide vane channels when the gap was larger than 0.2 mm. The HI of the blood pump with a 0.1 mm gap was 1.5-fold greater than that with a 0.3 mm gap. The results illustrated poor hydraulic characteristics when the gap was larger than 0.15 mm and rapidly deteriorated hemolysis when the gap was larger than 0.1 mm. The numerical and experimental results demonstrated that the pressure rise, pump efficiency, and scalar shear stress decreased when the gap increased. The HI did not strictly decrease with gap increases. The preliminary results encourage the improvement of axial blood pump designs.

  16. Accuracy of axial depth of cut in micromilling operations - Simplified procedure and uncertainty model

    DEFF Research Database (Denmark)

    Bissacco, Giuliano

    2005-01-01

    In order to maintain an optimum cutting speed, the reduction of mill diameters requires machine tools with high rotational speed capabilities. A solution to update existing machine tools is the use of high speed attached spindles. Major drawbacks of these attachments are the high thermal expansion...... and their rapid warming and cooling, which prevent the achievement of a steady state. Several other factors, independent on the tool-workpiece interaction, influence the machining accuracy. The cutting parameter most heavily affected is the axial depth of cut which is the most critical when using micro end mills......, due to the easy breakage particularly when milling on hard materials [1]. Typical values for the errors on the control of the axial depth of cut are in the order of 50 microns, while the aimed depth of cut can be as low as 5 microns. The author has developed a machining procedure for optimal control...

  17. A comprehensive method for preliminary design optimization of axial gas turbine stages. II - Code verification

    Science.gov (United States)

    Jenkins, R. M.

    1983-01-01

    The present effort represents an extension of previous work wherein a calculation model for performing rapid pitchline optimization of axial gas turbine geometry, including blade profiles, is developed. The model requires no specification of geometric constraints. Output includes aerodynamic performance (adiabatic efficiency), hub-tip flow-path geometry, blade chords, and estimates of blade shape. Presented herein is a verification of the aerodynamic performance portion of the model, whereby detailed turbine test-rig data, including rig geometry, is input to the model to determine whether tested performance can be predicted. An array of seven (7) NASA single-stage axial gas turbine configurations is investigated, ranging in size from 0.6 kg/s to 63.8 kg/s mass flow and in specific work output from 153 J/g to 558 J/g at design (hot) conditions; stage loading factor ranges from 1.15 to 4.66.

  18. Head Injuries in Soccer.

    Science.gov (United States)

    Myrick, Karen M

    2016-07-01

    Soccer is currently the most popular and fastest growing sport worldwide, with approximately 265 million registered soccer players existing around the world. The popularity of the sport, coupled with the high incidence of 18.8-21.5 head injuries per 1,000 player hours reported, make it essential that clinicians, coaches, and the athletes, have a solid understanding of head injuries. The successful rehabilitation of athletes with head injuries relies upon early and accurate identification strategies and implementation of appropriate return to play measures across all areas in the continuum of care. Soccer is a frequently played sport, and head injuries are common. Therefore, it is imperative that clinicians, coaches, and the athletes themselves have a solid understanding of head injury prevention, diagnosis, and treatment options. The purpose of this article was to provide rehabilitation nurses with current information regarding frequently occurring head injuries in the widespread sport of soccer. © 2015 Association of Rehabilitation Nurses.

  19. In Vivo Classification of Breast Masses Using Features Derived From Axial-Strain and Axial-Shear Images

    OpenAIRE

    Xu, Haiyan; Varghese, Tomy; Jiang, Jingfeng; Zagzebski, James A.

    2012-01-01

    Breast cancer is currently the second leading cause of cancer deaths in women. Early detection and accurate classification of suspicious masses as benign or malignant is important for arriving at an appropriate treatment plan. In this article, we present classification results for features extracted from ultrasound-based, axial-strain and axial-shear images of breast masses. The breast-mass stiffness contrast, size ratio, and a normalized axial-shear strain area feature are evaluated for the ...

  20. Head and Neck

    DEFF Research Database (Denmark)

    Højgaard, Liselotte; Berthelsen, Anne Kiil; Loft, Annika

    2014-01-01

    Positron emission tomography (PET)/computed tomography with FDG of the head and neck region is mainly used for the diagnosis of head and neck cancer, for staging, treatment evaluation, relapse, and planning of surgery and radio therapy. This article is a practical guide of imaging techniques......, including a detailed protocol for FDG PET in head and neck imaging, physiologic findings, and pitfalls in selected case stories....

  1. Pattern of CT Findings in Head Injuries: A Sub-urban Tertiary ...

    African Journals Online (AJOL)

    Fifty Eight patients referred to the Radiology department for Computerized axial Tomography following a road traffIC injury with a suspicion of head injury were studied. A retrospective review of the CT request cards, film reports and case notes (where available) were carried out. The mean age of patients was 34.8 ± 19.3 yrs ...

  2. Axially Symmetric Bianchi Type-I Bulk-Viscous Cosmological ...

    Indian Academy of Sciences (India)

    Home; Journals; Journal of Astrophysics and Astronomy; Volume 34; Issue 3. Axially Symmetric Bianchi ... The present study deals with spatially homogeneous and anisotropic axially symmetric Bianchi type-I cosmological model with time variable cosmological term in the presence of bulk viscous fluid. The Einstein's field ...

  3. Improved axial position detection in optical tweezers measurements

    DEFF Research Database (Denmark)

    Dreyer, Jakob Kisbye; Berg-Sørensen, Kirstine; Oddershede, Lene

    2004-01-01

    We investigate the axial position detection of a trapped microsphere in an optical trap by using a quadrant photodiode. By replacing the photodiode with a CCD camera, we obtain detailed information on the light scattered by the microsphere. The correlation of the interference pattern with the axial...

  4. Vector and axial vector mesons at finite temperature

    OpenAIRE

    mallik, S.; Sarkar, Sourav

    2002-01-01

    We consider the thermal correlation functions of vector and axial-vector currents and evaluate corrections to the vector and axial-vector meson pole terms to one loop in chiral perturbation theory. As expected, the pole positions do not shift to leading order in temperature. But the residues decrease with temperature.

  5. Test Setup for Axially Loaded Piles in Sand

    DEFF Research Database (Denmark)

    Thomassen, Kristina

    The test setup for testing axially static and cyclic loaded piles in sand is described in the following. The purpose for the tests is to examine the tensile capacity of axially loaded piles in dense fully saturated sand. The pile dimensions are chosen to resemble full scale dimension of piles used...... in offshore pile foundations today....

  6. Economic Restructuring and Changing Prevalence of Female-Headed Families in America.

    Science.gov (United States)

    McLaughlin, Diane K.; Gardner, Erica L.; Lichter, Daniel T.

    1999-01-01

    Analysis of census data indicates that female-headed households increased more rapidly in nonmetro than metro counties between 1980 and 1990; industrial restructuring contributed to change in nonmetro and metro female-headed households, with changes in various industries producing different effects; and formation of female-headed households was…

  7. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Computed tomography (CT) of the head uses special x-ray equipment to help assess head injuries, severe headaches, ... is a diagnostic medical test that, like traditional x-rays, produces multiple images or pictures of the inside ...

  8. Head Injuries in Children

    Science.gov (United States)

    Pennington, Nicole

    2010-01-01

    School nurses play a crucial role in injury prevention and initial treatment when injuries occur at school. The role of school nurses includes being knowledgeable about the management of head injuries, including assessment and initial treatment. The school nurse must be familiar with the outcomes of a head injury and know when further evaluation…

  9. Abnormal Head Position

    Science.gov (United States)

    ... non-ocular causes of an abnormal head position? Congenital shortening of the neck muscles (sternocleidomastoid) can cause a head tilt. This is ... amblyopia) are other treatment alternatives. Physical therapy helps congenital torticollis from tight neck muscles. Updated ... Terms & Conditions Most Common ...

  10. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... the limitations of CT Scanning of the Head? What is CT Scanning of the Head? Computed tomography, more commonly known as a CT or CAT scan, is a diagnostic medical test that, like traditional x-rays, produces multiple images or pictures of the inside of ...

  11. Head Start in Action.

    Science.gov (United States)

    Riley, Clara M. D.; Epps, Frances M. J.

    Records and observations from a summer Head Start program, conducted in Los Angeles by Delta Sigma Theta, are delineated in this book. It relates firsthand experiences of the participating personnel as they developed and implemented a Head Start program for some 300 children. The book is divided into three sections. Section I,…

  12. Biomechanics of Sports-Induced Axial-Compression Injuries of the Neck

    Science.gov (United States)

    Ivancic, Paul C.

    2012-01-01

    Context Head-first sports-induced impacts cause cervical fractures and dislocations and spinal cord lesions. In previous biomechanical studies, researchers have vertically dropped human cadavers, head-neck specimens, or surrogate models in inverted postures. Objective To develop a cadaveric neck model to simulate horizontally aligned, head-first impacts with a straightened neck and to use the model to investigate biomechanical responses and failure mechanisms. Design Descriptive laboratory study. Setting Biomechanics research laboratory. Patients or Other Participants Five human cadaveric cervical spine specimens. Intervention(s) The model consisted of the neck specimen mounted horizontally to a torso-equivalent mass on a sled and carrying a surrogate head. Head-first impacts were simulated at 4.1 m/s into a padded, deformable barrier. Main Outcome Measure(s) Time-history responses were determined for head and neck loads, accelerations, and motions. Average occurrence times of the compression force peaks at the impact barrier, occipital condyles, and neck were compared. Results The first local compression force peaks at the impact barrier (3070.0 ± 168.0 N at 18.8 milliseconds), occipital condyles (2868.1 ± 732.4 N at 19.6 milliseconds), and neck (2884.6 ± 910.7 N at 25.0 milliseconds) occurred earlier than all global compression peaks, which reached 7531.6 N in the neck at 46.6 milliseconds (P flexion. Neck compression fractures included occipital condyle, atlas, odontoid, and subaxial comminuted burst and facet fractures. Conclusions Neck injuries due to excessive axial compression occurred within 20 milliseconds of impact and were caused by abrupt deceleration of the head and continued forward torso momentum before simultaneous rebound of the head and torso. Improved understanding of neck injury mechanisms during sports-induced impacts will increase clinical awareness and immediate care and ultimately lead to improved protective equipment, reducing the

  13. Multimode interaction in axially excited cylindrical shells

    Directory of Open Access Journals (Sweden)

    Silva F. M. A.

    2014-01-01

    Full Text Available Cylindrical shells exhibit a dense frequency spectrum, especially near the lowest frequency range. In addition, due to the circumferential symmetry, frequencies occur in pairs. So, in the vicinity of the lowest natural frequencies, several equal or nearly equal frequencies may occur, leading to a complex dynamic behavior. So, the aim of the present work is to investigate the dynamic behavior and stability of cylindrical shells under axial forcing with multiple equal or nearly equal natural frequencies. The shell is modelled using the Donnell nonlinear shallow shell theory and the discretized equations of motion are obtained by applying the Galerkin method. For this, a modal solution that takes into account the modal interaction among the relevant modes and the influence of their companion modes (modes with rotational symmetry, which satisfies the boundary and continuity conditions of the shell, is derived. Special attention is given to the 1:1:1:1 internal resonance (four interacting modes. Solving numerically the governing equations of motion and using several tools of nonlinear dynamics, a detailed parametric analysis is conducted to clarify the influence of the internal resonances on the bifurcations, stability boundaries, nonlinear vibration modes and basins of attraction of the structure.

  14. Structured Light-Based Motion Tracking in the Limited View of an MR Head Coil

    DEFF Research Database (Denmark)

    Erikshøj, M.; Olesen, Oline Vinter; Conradsen, Knut

    2013-01-01

    of the facial surface. The point clouds are continuously realigned to a reference scan to obtain pose estimates. The system has been tested on a mannequin head performing controlled rotational and translational axial movements within the head coil outside the range of the magnetic field. The RMS of the residual......A markerless motion tracking (MT) system developed for use in PET brain imaging has been tested in the limited field of view (FOV) of the MR head coil from the Siemens Biograph mMR. The system is a 3D surface scanner that uses structured light (SL) to create point cloud reconstructions...

  15. Análisis de la fuerza axial en un transportador de sinfín // Analysis of axial force in a screw conveyor.

    Directory of Open Access Journals (Sweden)

    F. Aguilar Parés

    1999-01-01

    Full Text Available Durante el movimiento de un material en un transportador de sinfín surge una fuerza en dirección axial que influye en laselección de uno de los cojinetes de apoyo del equipo. En el artículo aparecen algunas soluciones constructivas que tienen encuentan la fuerza axial. Por otro lado se establece la relación entre la fuerza axial y el empuje axial y se precisa de quiendepende el sentido del empuje axial. Por último se propone un modelo matemático que relaciona la fuerza axial con la potenciarequerida por el equipo.Palabras claves: Transportador de sinf in, fuerza axial , empuje axial ._________________________________________________________________________AbstractDuring the movement of material in a screw conveyor surge a force in axial direction that influence in the selection of one ofthe equipment support bearings. Some constructive solutions appear in the article for considering the axial force. In the otherhand it is established the relation between axial force and axial thurst and it is precised whose direction thurst axial depend of.Finally it is proposed a mathematic model that relates the axial force with the power required by the equipment.Key words: Screw conveyor, axial force, axial thurst .

  16. Baseline head in Olkiluoto

    Energy Technology Data Exchange (ETDEWEB)

    Ahokas, H.; Tammisto, E.; Lehtimaeki, T. (Poeyry Environment Oy, Vantaa (Finland))

    2008-11-15

    As part of the programme for the final disposal of the spent nuclear fuel, Posiva Oy investigates the prevailing hydrological conditions on Olkiluoto island. The hydrological investigations have included several kinds of hydrological tests such as measurements of hydraulic conductivity by flow logging and a double-packer tool as well as interference tests by pumping, in order to study the hydraulic connections between the drillholes. In addition, long-term monitoring of groundwater level and groundwater head as well as measurements of flow conditions in open drillholes, groundwater salinity (in situ EC), precipitation (including snow), sea-water level, surface flow (runoff) etc. have been part of the investigation programme aiming at the characterization of the bedrock. The data have been used in the compilation of deterministic hydro-zones and hydraulic properties for numerical flow modelling to study the flow pattern on Olkiluoto island. In addition, the compiled bedrock models have been used in the planning of the repository layout and in the analyses of the transport of radionuclides and the functionality of engineered barriers. This report focuses on the measurements of groundwater head by means of multi-packers and in connection with flow loggings. The determination of the undisturbed groundwater head (baseline head) in terms of the in situ fresh water head is the main goal of this report. The density of groundwater is strongly dependent on salinity and due to the saline groundwater deep in the bedrock in Olkiluoto the term fresh water head is used instead of hydraulic head. Taking the density of groundwater into account, the gradient of the residual pressure, which actually causes groundwater flow can be calculated. The measured and calculated heads are converted into corresponding in situ fresh water heads, which correspond to the water level (metres above sea level) in the hose that runs from the packed-off section to the ground surface. This means that

  17. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... the limitations of MRI of the Head? What is MRI of the Head? Magnetic resonance imaging (MRI) is a noninvasive ... top of page What are some common uses of the procedure? MR imaging of the head is ...

  18. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... MRI of the Head? What is MRI of the Head? Magnetic resonance imaging (MRI) is a noninvasive ... of page What are some common uses of the procedure? MR imaging of the head is performed ...

  19. Ulnar head replacement.

    Science.gov (United States)

    Herbert, Timothy J; van Schoonhoven, Joerg

    2007-03-01

    Recent years have seen an increasing awareness of the anatomical and biomechanical significance of the distal radioulnar joint (DRUJ). With this has come a more critical approach to surgical management of DRUJ disorders and a realization that all forms of "excision arthroplasty" can only restore forearm rotation at the expense of forearm stability. This, in turn, has led to renewed interest in prosthetic replacement of the ulnar head, a procedure that had previously fallen into disrepute because of material failures with early implants, in particular, the Swanson silicone ulnar head replacement. In response to these early failures, a new prosthesis was developed in the early 1990s, using materials designed to withstand the loads across the DRUJ associated with normal functional use of the upper limb. Released onto the market in 1995 (Herbert ulnar head prosthesis), clinical experience during the last 10 years has shown that this prosthesis is able to restore forearm function after ulnar head excision and that the materials (ceramic head and noncemented titanium stem), even with normal use of the limb, are showing no signs of failure in the medium to long term. As experience with the use of an ulnar head prosthesis grows, so does its acceptance as a viable and attractive alternative to more traditional operations, such as the Darrach and Sauve-Kapandji procedures. This article discusses the current indications and contraindications for ulnar head replacement and details the surgical procedure, rehabilitation, and likely outcomes.

  20. Comparison of axial and radial electron beam-breakup transit-time oscillators

    Energy Technology Data Exchange (ETDEWEB)

    Kwan, T.J.T. [Los Alamos National Lab., NM (United States); Mostrom, M.A. [Mission Research Corporation, Albuquerque, NM (United States)

    1995-08-01

    Comparison of two configurations of a novel high-power microwave generator is presented in this article. Coupling the beam-breakup instability with the transit-time effect of the electron beam in the cavity, rapid energy exchange between the electrons and cavity modes can occur. The dominant cavity modes in the axial and radial configurations are different but their growth rates are comparable. We found that the radial configuration can have a beam impedance less than 10 {Omega} and therefore more suitable for low-voltage and high power operation. Good agreements have been obtained between linear theory and simulation for both configurations.

  1. Water translocation from the axial cylinder to myelin sheath structures of the nerve fiber.

    Science.gov (United States)

    Sotnikov, O S; Kokurina, T N; Kuznetsova, I N; Vasyagina, N Yu

    2011-10-01

    We studied isolated myelinated nerve fibers from frog sciatic nerve surviving in Ringer solution or in water-free liquid perfluorodecalin immiscible with water or mineral oil. Swelling of incisures and perikaryon, loosening of myelin in the node, and formation of the axial cylinder varicosities were found in the fibers surviving in Ringer solution after 5-7 h. The same process, swelling of Schmidt-Lantermann myelin incisures, Schwann cell perikaryon, and loosening of myelin lamellae in the Ranvier nodes was found in water-free perfluorodecalin medium. However, swelling of the perikaryon and incisures spread along the axial cylinder and the reaction of the fiber developed in perfluorodecalin much later and unfolded slower than in the control. These changes developed much sooner and progressed much more rapidly than in perfluorodecalin in fibers surviving in mineral oil. Swelling of the myelin sheath structures in water-free medium indicated an uncommon new form of the neuron-glia relationships: water translocation from the axial cylinder to Schwann cell under unfavorable conditions.

  2. Axial elongation following prolonged near work in myopes and emmetropes.

    Science.gov (United States)

    Woodman, Emily C; Read, Scott A; Collins, Michael J; Hegarty, Katherine J; Priddle, Scott B; Smith, Josephine M; Perro, Judd V

    2011-05-01

    To investigate the influence of a period of sustained near work upon axial length in groups of emmetropes (EMM) and myopes. Forty young adult subjects (20 myopes and 20 emmetropes) were recruited for the study. Myopes were further classified as early onset (EOM), late onset (LOM), stable (SM) or progressing (PM) subgroups. Axial length was measured with the IOLMaster instrument before, immediately after and then again 10 min after a continuous 30 min near task of 5 D accommodation demand. Measures of distance objective refraction were also collected. Significant changes in axial length were observed immediately following the near task. EOM axial length elongated on average by 0.027±0.021 mm, LOM by 0.014±0.020 mm, EMM by 0.010±0.015 mm, PM by 0.031±0.022 mm and SM by 0.014±0.018 mm. At the conclusion of the 10 min regression period, axial length measures were not significantly different from baseline values. Axial elongation was observed following a prolonged near task. Both EOM and PM groups showed increases in axial length that were significantly greater than emmetropes.

  3. Physics based modeling of axial compressor stall

    Science.gov (United States)

    Zaki, Mina Adel

    2009-12-01

    Axial compressors are used in a wide variety of aerodynamic applications and are one of the most important components in aero-engines. However, the operability of compressors is limited at low-mass flow rates by fluid dynamic instabilities such as stall and surge. These instabilities can lead to engine failure and loss of engine power which can compromise the aircraft safety and reliability. Thus, a better understanding of how stall occurs and the causes behind its inception is extremely important. In the vicinity of the stall line, the flow field is inherently unsteady due to the interactions between adjacent rows of blades, formation of separation cells, and the viscous effects including shock-boundary layer interactions. Accurate modeling of these phenomena requires a proper set of stable and accurate boundary conditions at the rotor-stator interface that conserve mass, momentum, and energy, while eliminating false reflections. As a part of this research effort, an existing 3-D Navier-Stokes analysis for modeling single stage compressors has been modified to model multi-stage axial compressors and turbines. Several rotor-stator interface boundary conditions have been implemented. These conditions have been evaluated for the first stage (a stator and a rotor) of the two-stage fuel turbine on the space shuttle main engine (SSME). Their effectiveness in conserving global properties such as mass, momentum, and energy across the interface while yielding good performance predictions has been evaluated. While all the methods gave satisfactory results, a characteristic based approach and an unsteady sliding mesh approach are found to work best. Accurate modeling of the formation of stall cells requires the use of advanced turbulence models. As a part of this effort, a new advanced turbulence model called the Hybrid RANS/KES (HRKES) model has been developed and implemented. This model solves the Menter's k-o-SST model near walls and switches to the Kinetic Eddy

  4. Impact of pupil diameter on axial growth in orthokeratology.

    Science.gov (United States)

    Chen, Zhi; Niu, Lingling; Xue, Feng; Qu, Xiaomei; Zhou, Zimei; Zhou, Xingtao; Chu, Renyuan

    2012-11-01

    To compare axial elongation between myopic orthokeratology (OK) contact lens and spectacle wearers, and to investigate the impact of pupil diameter on axial growth in myopic children after OK treatment. Fifty-two Chinese children aged 9 to 14 years were enrolled in this study, 27 for the OK group and 25 for the single vision spectacle lenses (SVL) group. Subjects in each group were further divided into two subcategories according to their baseline scotopic pupil diameters. Axial length (AL) was measured at baseline and at every 6-month visit through to 24 months. Linear mixed-effect model was used to determine myopia progression (AL changes from baseline). In this model, repeated visits were taken as within-subject effect, and treatment group as well as pupil size were taken as between-subject effects. The interaction of treatment group*pupil size was analyzed. Relationships between axial growth at 24 months and baseline pupil area were analyzed in both lens groups. Twenty-five subjects in the OK group and 22 subjects in the SVL group completed the 24-month study. AL increased significantly throughout the observed 24-month period (F = 32.09, p Pupil size significantly affected axial growth (F = 15.95, p pupil size on axial growth (F = 24.66, p pupil sizes than those with below average pupil sizes in the OK group (F = 25.04, p pupil size did not affect axial growth in the SVL group (F = 0.46, p = 0.50). Baseline scotopic pupil area was significantly correlated to axial growth in the OK group (r = 0.405, p pupil diameters facilitate the effect of OK to slow axial growth in myopia. We speculate that this is because of enhancement of the myopic shift in the peripheral retina.

  5. Identifying Axial Spondyloarthritis in Electronic Medical Records of US Veterans.

    Science.gov (United States)

    Walsh, Jessica A; Shao, Yijun; Leng, Jianwei; He, Tao; Teng, Chia-Chen; Redd, Doug; Treitler Zeng, Qing; Burningham, Zachary; Clegg, Daniel O; Sauer, Brian C

    2017-09-01

    Large database research in axial spondyloarthritis (SpA) is limited by a lack of methods for identifying most types of axial SpA. Our objective was to develop methods for identifying axial SpA concepts in the free text of documents from electronic medical records. Veterans with documents in the national Veterans Health Administration Corporate Data Warehouse between January 1, 2005 and June 30, 2015 were included. Methods were developed for exploring, selecting, and extracting meaningful terms that were likely to represent axial SpA concepts. With annotation, clinical experts reviewed sections of text containing the meaningful terms (snippets) and classified the snippets according to whether or not they represented the intended axial SpA concept. With natural language processing (NLP) tools, computers were trained to replicate the clinical experts' snippet classifications. Three axial SpA concepts were selected by clinical experts, including sacroiliitis, terms including the prefix spond*, and HLA-B27 positivity (HLA-B27+). With supervised machine learning on annotated snippets, NLP models were developed with accuracies of 91.1% for sacroiliitis, 93.5% for spond*, and 97.2% for HLA-B27+. With independent validation, the accuracies were 92.0% for sacroiliitis, 91.0% for spond*, and 99.0% for HLA-B27+. We developed feasible and accurate methods for identifying axial SpA concepts in the free text of clinical notes. Additional research is required to determine combinations of concepts that will accurately identify axial SpA phenotypes. These novel methods will facilitate previously impractical observational research in axial SpA and may be applied to research with other diseases. © 2016, American College of Rheumatology.

  6. Dispositivos de asistencia ventricular de tipo axial

    Directory of Open Access Journals (Sweden)

    Albert Miralles Cassina

    2009-04-01

    Full Text Available El uso de dispositivos de asistencia ventricular se ha ido extendiendo en las últimas décadas. La mejora de los resultados ha ido acompañada del diseño de nuevos aparatos más pequeños y eficientes como son las bombas de flujo axial. las características técnicas básicas de estos dispositivos se hallan en la generación de un flujo continuo unidireccional conseguido mediante sistemas de turbina que obtienen su alimentación de una fuente eléctrica. Las ventajas principales de estos dispositivos son: su facilidad de implantación por su tamaño reducido, su prolongada durabilidad gracias a su sencillo diseño y su eficiencia energética al utilizar energía eléctrica. Su utilidad se ha podido demostrar en diferentes indicaciones de asistencia circulatoria mecánica, como en el caso de puente al trasplante o dispositivo de recuperación miocárdica, si bien donde radica más interés es en su uso como sistemas de asistencia circulatoria mecánica definitiva. Existe una variedad de modelos de diversos diseños. Son dispositivos que permiten soporte normalmente univentricular izquierdo, que se implantan en el tórax con cánula de entrada a nivel ventricular y cánula de salida a nivel aórtico. En este artículo se efectúa una descripción de los principales sistemas disponibles en la actualidad, comentando las características técnicas, ventajas e inconvenientes y un resumen de la experiencia existente.

  7. Axially Ligated Phthalocyanine Conductors with Magnetic Moments

    Directory of Open Access Journals (Sweden)

    Tamotsu Inabe

    2017-04-01

    Full Text Available This mini-review describes electrical conductivity, magnetic properties, and magnetotransport properties of one-dimensional partially oxidized salts composed of axially ligated phthalocyanines, TPP[M(Pc(CN2]2 (TPP = tetraphenylphosphonium, Pc = phthalocyaninato, with M of Fe (d5, S = 1/2 and Cr (d3, S = 3/2. These salts are isomorphous, and π–π interactions in the crystal, that becomes the origin of the charge carriers, are nearly the same. Both the Fe and Cr salts show carrier localization and charge disproportionation which is enhanced by the interaction between local magnetic moments and conduction π-electrons (π–d interaction. However, the magnetic properties are slightly different between them. M = Fe has been found to show unique anisotropic magnetic properties and antiferromagnetic short-range magnetic order between the d-spins. On the other hand, for M = Cr, its magnetic moment is isotropic. Temperature dependence of the magnetic susceptibility shows typical Curie–Weiss behavior with negative Weiss temperature, but the exchange interaction is complicated. Both M = Fe and M = Cr show large negative magnetoresistance, reflecting the difference in the anisotropy. The magnetoresistance ratio (MR is larger in the Fe system than in the Cr system in the low magnetic field range, but MR in the Cr system exceeds that in the Fe system when the magnetic field becomes higher than 15 T. We discuss the mechanism of the giant negative magnetoresistance with reference to the d–d, π–d, and π–π interactions.

  8. [Extra-axial tumors of the central nervous system].

    Science.gov (United States)

    Mühl-Benninghaus, R

    2017-09-01

    Extra-axial tumors are intracranial neoplasms but are not located within the brain parenchyma. The localization of intracranial neoplasms helps to narrow down the possible differential diagnoses and also plays a deciding role in the treatment strategy and the prognosis. For this reason exact localization of these lesions is extremely important. Extra-axial tumors are the most common neoplasms among adults. They can be divided in a broad spectrum of histopathological subgroups. The most common extra-axial tumors are meningiomas, which arise from the dura mater. In the vast majority of cases they are benign and slowly growing. Only a few rare subgroups show aggressive behavior.

  9. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... you! Do you have a personal story about radiology? Share your patient story here Images × Image Gallery ... Pregnancy Head and Neck Cancer X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to ...

  10. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... Tomography (CT) Safety During Pregnancy Head and Neck Cancer X-ray, Interventional Radiology and Nuclear ... or other physician. To locate a medical imaging or radiation oncology provider in your community, you can search the ...

  11. Overview of Head Injuries

    Science.gov (United States)

    ... brain. If the head injury is very severe, mechanical ventilation may be used. Doctors control blood pressure and minimize the amount of brain swelling by adjusting the amount of intravenous fluids given and sometimes by giving intravenous drugs that ...

  12. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... headaches, dizziness, and other symptoms of aneurysm, bleeding, stroke and brain tumors. It also helps your doctor ... scanning provides more detailed information on head injuries, stroke , brain tumors and other brain diseases than regular ...

  13. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... be necessary. Your doctor will explain the exact reason why another exam is requested. Sometimes a follow- ... limitations of CT Scanning of the Head? A person who is very large may not fit into ...

  14. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... medically necessary because of potential risk to the baby. This risk is, however, minimal with head CT ... intravenous contrast indicate mothers should not breastfeed their babies for 24-48 hours after contrast medium is ...

  15. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... assess head injuries, severe headaches, dizziness, and other symptoms of aneurysm, bleeding, stroke and brain tumors. It ... within the brain shortly after a patient exhibits symptoms of a stroke. a stroke, especially with a ...

  16. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... scans in children should always be done with low-dose technique. top of page What are the ... page Additional Information and Resources RTAnswers.org Radiation Therapy for Brain Tumors Radiation Therapy for Head and ...

  17. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... this tunnel. Rotating around you, the x-ray tube and electronic x-ray detectors are located opposite ... medically necessary because of potential risk to the baby. This risk is, however, minimal with head CT ...

  18. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... microphone. top of page How does the procedure work? In many ways CT scanning works very much ... head CT scanning. Manufacturers of intravenous contrast indicate mothers should not breastfeed their babies for 24-48 ...

  19. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... special x-ray equipment to help assess head injuries, severe headaches, dizziness, and other symptoms of aneurysm, ... cancer. In emergency cases, it can reveal internal injuries and bleeding quickly enough to help save lives. ...

  20. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... traditional x-rays, particularly of soft tissues and blood vessels. CT scanning provides more detailed information on head injuries, stroke , brain tumors and other brain diseases than regular radiographs (x-rays). top of page ...

  1. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... used to detect: bleeding, brain injury and skull fractures in patients with head injuries. bleeding caused by ... a few seconds, and even faster in small children. Such speed is beneficial for all patients but ...

  2. TCGA head Neck

    Science.gov (United States)

    Investigators with The Cancer Genome Atlas (TCGA) Research Network have discovered genomic differences – with potentially important clinical implications – in head and neck cancers caused by infection with the human papillomavirus (HPV).

  3. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... microphone. top of page How does the procedure work? In many ways CT scanning works very much ... for Head and Neck Cancer Others American Stroke Association National Stroke Association top of page This page ...

  4. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... images of internal organs, bones, soft tissue and blood vessels provide greater detail than traditional x-rays, particularly of soft tissues and blood vessels. CT scanning provides more detailed information on head ...

  5. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... sometimes compared to looking into a loaf of bread by cutting the loaf into thin slices. When ... for Brain Tumors Radiation Therapy for Head and Neck Cancer Others American Stroke Association National Stroke Association ...

  6. Early Head Start Evaluation

    Data.gov (United States)

    U.S. Department of Health & Human Services — Longitudinal information from an evaluation where children were randomly assigned to Early Head Start or community services as usual;direct assessments and...

  7. Head Start Impact Study

    Data.gov (United States)

    U.S. Department of Health & Human Services — Nationally representative, longitudinal information from an evaluation where children were randomly assigned to Head Start or community services as usual;direct...

  8. Head CT scan

    Science.gov (United States)

    ... be: Stored Viewed on a monitor Printed on film Three-dimensional models of the head area can ... when you have certain other signs or symptoms Hearing loss (in some people) Symptoms of damage to ...

  9. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... and other symptoms of aneurysm, bleeding, stroke and brain tumors. It also helps your doctor to evaluate your ... provides more detailed information on head injuries, stroke , brain tumors and other brain diseases than regular radiographs (x- ...

  10. Head and Neck Cancer

    Science.gov (United States)

    ... increase the risk of head and neck cancer. Environmental or occupational inhalants. Inhaling asbestos, wood dust, paint ... from the American Society of Clinical Oncology. Review dictionary articles to help understand medical phrases and terms ...

  11. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... used to detect: bleeding, brain injury and skull fractures in patients with head injuries. bleeding caused by ... are present in the paranasal sinuses. plan radiation therapy for cancer of the brain or other tissues. ...

  12. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... used to detect: bleeding, brain injury and skull fractures in patients with head injuries. bleeding caused by ... is also performed to: evaluate the extent of bone and soft tissue damage in patients with facial ...

  13. Rapid Prototyping

    Science.gov (United States)

    1999-01-01

    Javelin, a Lone Peak Engineering Inc. Company has introduced the SteamRoller(TM) System as a commercial product. The system was designed by Javelin during a Phase II NASA funded small commercial product. The purpose of the invention was to allow automated-feed of flexible ceramic tapes to the Laminated Object Manufacturing rapid prototyping equipment. The ceramic material that Javelin was working with during the Phase II project is silicon nitride. This engineered ceramic material is of interest for space-based component.

  14. Head Injury, from Men to Model

    OpenAIRE

    Brink, Willem Aart

    2000-01-01

    textabstractIn well developed countries, injury is the leading cause of death and disability among young adults. In less developed countries the incidence of injury is high and rapidly increasing, but the relative mortality due to injuries is overshadowed by other causes, such as infections and malnutrition. In the United States of America each year approximately 1.000.000 people are treated and released from hospital emergency departments because of head injury. About 80% of patients receivi...

  15. Numerical and experimental research of flow and sound fields in an axial-flow check valve and its optimization

    Directory of Open Access Journals (Sweden)

    Jianping Yu

    2015-11-01

    Full Text Available In order to find a proper method to study the flow and sound fields in an axial-flow check valve, the jetting noise at a nozzle is investigated with simulations and experiments. Based on optimization principle, the main channel of the valve body is numerically investigated and optimized twice. The results show that the resistance coefficient and the maximum noise of the valve are decreased by 0.37 and 23.8 dB, respectively, and the head and the tail of the valve plug are optimized when streamline design is employed on the main channel structure of the valve body.

  16. Uniform Decay for Solutions of an Axially Moving Viscoelastic Beam

    Energy Technology Data Exchange (ETDEWEB)

    Kelleche, Abdelkarim, E-mail: kellecheabdelkarim@gmail.com [Université des Sciences et de la Technologie Houari Boumediene, Faculté des Mathématiques (Algeria); Tatar, Nasser-eddine, E-mail: tatarn@Kfupm.edu.sa [King Fahd University of Petroleum and Minerals, Department of Mathematics and Statistics (Saudi Arabia)

    2017-06-15

    The paper deals with an axially moving viscoelastic structure modeled as an Euler–Bernoulli beam. The aim is to suppress the transversal displacement (transversal vibrations) that occur during the axial motion of the beam. It is assumed that the beam is moving with a constant axial speed and it is subject to a nonlinear force at the right boundary. We prove that when the axial speed of the beam is smaller than a critical value, the dissipation produced by the viscoelastic material is sufficient to suppress the transversal vibrations. It is shown that the rate of decay of the energy depends on the kernel which arise in the viscoelastic term. We consider a general kernel and notice that solutions cannot decay faster than the kernel.

  17. Massive Axial Gauge in the Exact Renormalization Group Approach

    Science.gov (United States)

    Panza, P.; Soldati, R.

    The Exact Renormalization Group (ERG) approach to massive gauge theories in the axial gauge is studied and the smoothness of the massless limit is analysed for a formally gauge invariant quantity such as the Euclidean Wilson loop.

  18. Landforms along transverse faults parallel to axial zone of folded ...

    Indian Academy of Sciences (India)

    -4. Landforms along transverse faults parallel to axial zone of folded mountain front, north-eastern Kumaun. Sub-Himalaya, India. Khayingshing Luirei∗. , S S Bhakuni and Sanjay S Negi. Wadia Institute of Himalayan Geology, Dehradun, India.

  19. Axial squeeze strengthen effect on rotary magneto-rheological damper

    Science.gov (United States)

    Dong, Xiaomin; Duan, Chi; Yu, Jianqiang

    2017-05-01

    Pressure is an important factor to influence the performance of an magneto-rheological (MR) apparatus. The effect of the axial squeeze strengthen effect on rotary MR damper is investigated theoretically and experimentally in this study. First, a theoretical analysis in a microscopic view is proposed. It indicates that a concentrated increment of iron particle content in the working gap results in the effect. Then, a pressure-controlled rotary MR damper with the axial squeeze strengthen effect is designed, manufactured and tested. The results show that the axial squeeze strengthen effect on rotary MR damper is remarkable for the damper with lower particle content in MR fluids. In addition, there is an optimal pressure to obtain the maximum axial squeeze strengthen effect on the rotary MR damper.

  20. Time Domain Terahertz Axial Computed Tomography Non Destructive Evaluation Project

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to demonstrate key elements of feasibility for a high speed automated time domain terahertz computed axial tomography (TD-THz CT) non destructive...

  1. Effect of axial heat flux distribution on CHF

    Energy Technology Data Exchange (ETDEWEB)

    Park, Cheol

    2000-10-01

    Previous investigations for the effect of axial heat flux distributions on CHF and the prediction methods are reviewed and summarized. A total of 856 CHF data in a tube with a non-uniform axial heat flux distribution has been compiled from the articles and analyzed using the 1995 Groeneveld look-up table. The results showed that two representative correction factors, K5 of the look-up table and Tongs F factor, can be applied to describe the axial heat flux distribution effect on CHF. However, they overpredict slightly the measured CHF, depending on the quality and flux peak shape. Hence, a corrected K5 factor, which accounts for the axial heat flux distribution effect is suggested to correct these trends. It predicted the CHF power for the compiled data with an average error of 1.5% and a standard deviation of 10.3%, and also provides a reasonable prediction of CHF locations.

  2. Time Domain Terahertz Axial Computed Tomography Non Destructive Evaluation Project

    Data.gov (United States)

    National Aeronautics and Space Administration — In this Phase 2 project, we propose to develop, construct, and deliver to NASA a computed axial tomography time-domain terahertz (CT TD-THz) non destructive...

  3. AXIAL CHEMICAL HETEROGENEITY OF CONTINUOUSLY CASTED STEEL INGOTS

    Directory of Open Access Journals (Sweden)

    Ju. A. Samojlovich

    2005-01-01

    Full Text Available The results of theoretical description of the process of the axial chemical heterogeneity formation in continuously cast slug taking into account heat, diffusion and hydrodynamic phenomenon in two-phase zone of hardening steel are given.

  4. Axial Torsion of Gangrenous Meckel's Diverticulum Causing Small ...

    African Journals Online (AJOL)

    Axial Torsion of Gangrenous Meckel's Diverticulum Causing. Small Bowel Obstruction. K. Sasikumar, Ravinder Naik Noonavath, G. S. Sreenath, Nanda Kishore Maroju. INTRODUCTION. Meckel's diverticulum (MD) is a commonly encountered congenital anomaly of the small intestine. Autopsy studies estimate overall.

  5. Comparison of rotordynamic fluid forces in axial inducers and centrifugal turbopump impellers

    Science.gov (United States)

    d'Agostino, Luca

    2016-05-01

    The paper illustrates and compares the results of the experimental campaigns carried out in the Cavitating Pump Rotordynamic Test Facility (CPRTF) at Alta, Italy, under ESA funding for the characterization of the lateral rotordynamic fluid forces acting on high-head axial inducers and centrifugal turbopump impellers for space propulsion applications. The configurations presented here refer to a three-bladed tapered-hub, variable-pitch, inducer (DAPROT3) and a single-stage centrifugal pump (VAMPIRE) with vaneless diffuser and single spiral volute. Both the centrifugal pump and the inducer have been designed by means of reduced order models specifically developed by the author and his collaborators for the geometric definition and performance prediction of this kind of hydraulic turbomachinery. Continuous spectra of the rotordynamic forces acting on the impellers as functions of the whirl frequency have been obtained by means of the novel technique recently developed and demonstrated at Alta. The influence of the rotor whirl motion, flow rate, cavitating conditions, and liquid temperature (thermal cavitation effects) on the rotordynamic fluid forces is illustrated and the observed differences in their behavior in axial inducers and centrifugal turbpumps are discussed and interpreted in the light of the outcome of recent cavitation visualization experiments carried out by the Chemical Propulsion Team at Alta.

  6. Analysis of Three-dimension Viscous Flow in the Model Axial Compressor Stage K1002L

    Science.gov (United States)

    Tribunskaia, K.; Kozhukhov, Y. V.

    2017-08-01

    The main investigation subject considered in this paper is axial compressor model stage K1002L. Three simulation models were designed: Scheme 1 - inlet stage model consisting of IGV (Inlet Guide Vane), rotor and diffuser; Scheme 2 - two-stage model: IGV, first-stage rotor, first-stage diffuser, second-stage rotor, EGV (Exit Guide Vane); Scheme 3 - full-round model: IGV, rotor, diffuser. Numerical investigation of the model stage was held for four circumferential velocities at the outer diameter (Uout=125,160,180,210 m/s) within the range of flow coefficient: ϕ = 0.4 - 0.6. The computational domain was created with ANSYS CFX Workbench. According to simulation results, there were constructed aerodynamic characteristic curves of adiabatic efficiency and the adiabatic head coefficient calculated for total parameters were compared with data from the full-scale test received at the Central Boiler and Turbine Institution (CBTI), thus, verification of the calculated data was carried out. Moreover, there were conducted the following studies: comparison of aerodynamic characteristics of the schemes 1, 2; comparison of the sector and full-round models. The analysis and conclusions are supplemented by gas-dynamic method calculation for axial compressor stages.

  7. Testing of Axially Loaded Bucket Foundation with Applied Overburden Pressure

    DEFF Research Database (Denmark)

    Vaitkunaite, Evelina; Ibsen, Lars Bo; Nielsen, Benjaminn Nordahl

    This report analyses laboratory testing data performed with a bucket foundation model subjected to axial loading. The examinations were conducted at the Geotechnical laboratory of Aalborg University. The report aims at showing and discussing the results of the static and cyclic axial loading tests...... on the bucket foundation model. Finally, a cyclic loading interaction diagram is given that can be applied for a full-scale bucket foundation design....

  8. The research on flow pulsation characteristics of axial piston pump

    Science.gov (United States)

    Wang, Bingchao; Wang, Yulin

    2017-01-01

    The flow pulsation is an important factor influencing the axial piston pump performance. In this paper we implement modeling and simulation of the axial piston pump with AMESim software to explore the flow pulsation characteristics under various factors . Theory analysis shows the loading pressure, angular speed, piston numbers and the accumulator impose evident influence on the flow pulsation characteristics. This simulation and analysis can be used for reducing the flow pulsation rate via properly setting the related factors.

  9. Axial myopia in computed and magnetic resonance tomography

    Energy Technology Data Exchange (ETDEWEB)

    Beyer-Enke, S.A.; Goerich, J.; Gamroth, A.

    1987-08-01

    The case of a 44-year old woman suffering from amblyopia on the left eye with unilateral proptosis caused by axial (progressive) myopia is presented. The clinical and radiological findings were discussed in reference to the literature. The diagnosis was established by ruling out neoplastic, inflammatory or endocrine causes for the exophtalmos. CT and MR scans revealed an enlarged left globe without evidence of orbital masses. The findings were regarded as typical for the diagnosis at axial myopia.

  10. Design and Test of a Transonic Axial Splittered Rotor

    Science.gov (United States)

    2015-06-15

    AXIAL SPLITTERED ROTOR A new design procedure was developed that uses commercial-off-the- shelf software (MATLAB, SolidWorks, and ANSYS-CFX) for the...TRANSONIC AXIAL SPLITTERED ROTOR Report Title A new design procedure was developed that uses commercial-off-the- shelf software (MATLAB, SolidWorks, and... placement , and performance benefits. In particular, it was determined that moving the splitter blade forward in the passage between the main blades

  11. Goldenhar syndrome with unusual association of pre-axial polydactyly.

    Science.gov (United States)

    Mishra, Deepak; Sinha, Bibhuti P; Kumar, Rakesh

    2009-01-01

    Goldenhar syndrome is a multiorgan involvement affecting mainly the eyes, auricle, and oral cavity. METHOD. Case report. A 7-month-old boy presenting with features of Goldenhar syndrome had ocular and auricular manifestations. There were no vertebral anomalies, but he had the unusual association of pre-axial polydactyly, which is not reported in the literature. Pre-axial polydactyly should also be considered as an association of Goldenhar syndrome.

  12. Reactive control of subsonic axial fan noise in a duct.

    Science.gov (United States)

    Liu, Y; Choy, Y S; Huang, L; Cheng, L

    2014-10-01

    Suppressing the ducted fan noise at low frequencies without varying the flow capacity is still a technical challenge. This study examines a conceived device consisting of two tensioned membranes backed with cavities housing the axial fan for suppression of the sound radiation from the axial fan directly. The noise suppression is achieved by destructive interference between the sound fields from the axial fan of a dipole nature and sound radiation from the membrane via vibroacoustics coupling. A two-dimensional model with the flow effect is presented which allows the performance of the device to be explored analytically. The air flow influences the symmetrical behavior and excites the odd in vacuo mode response of the membrane due to kinematic coupling. Such an asymmetrical effect can be compromised with off-center alignment of the axial fan. Tension plays an important role to sustain the performance to revoke the deformation of the membrane during the axial fan operation. With the design of four appropriately tensioned membranes covered by a cylindrical cavity, the first and second blade passage frequencies of the axial fan can be reduced by at least 20 dB. The satisfactory agreement between experiment and theory demonstrates that its feasibility is practical.

  13. Axial design of nuclear fuel using path relinking; Diseno axial de combustible nuclear utilizando path relinking

    Energy Technology Data Exchange (ETDEWEB)

    Castillo, A.; Torres, M.; Ortiz, J. J.; Perusquia, R.; Hernandez, J. L.; Montes, J. L. [ININ, 52750 La Marquesa, Estado de Mexico (Mexico)]. e-mail: jacm@nuclear.inin.mx

    2008-07-01

    In the present work the preliminary results were obtained with the zoctli system whose purpose is the axial design of assembly of nuclear fuel under certain considerations. For the mentioned design well-know cells were already used and that they have been proven in diverse cycles of operation in the nuclear power plant of Laguna Verde. The design contemplates fuels assemblies of 10x10 and with 2 water channels. The assembly was distributed in 6 axial zones according to its structure. In order to take to end the optimization is was used the well-known technique like Path relinking and to find the group of previous solutions required by this technique uses the technical Taboo search. In order to work with Path relinking, 5 trajectories was taken in to account from a set of 5 previous solutions generated with theTaboo search, the update of the group of solutions is carried out in dynamic form. In the case of the Taboo search it was used a list of variable size, it was implement an aspiration approach, it was used the vector of frequencies and due to the cost of the evaluation of the objective function, only it was review 5% of the vicinity. For the objective function was considered the limit thermal, the axial profile of power, the effective multiplication factor and the margin of having turned off in cold. In order to prove the design system, it was used a balance cycle with a value of reference of 0.9928 for the effective multiplication factor that is equivalent to a produced energy of 10896 MWd/TU at the end of operation to full power. The designed assemblies were placed both in one of lots different from fresh assemblies on which it counts the referred cycle. At the end one a comparison with the results obtained with other techniques and under similar conditions is made. The results obtained until the moment show an appropriate performance of the system. It is possible to indicate that a small inconvenient is the amount of consumed resources of calculation during

  14. Axis of eye rotation changes with head-pitch orientation during head impulses about earth-vertical.

    Science.gov (United States)

    Migliaccio, Americo A; Schubert, Michael C; Clendaniel, Richard A; Carey, John P; Della Santina, Charles C; Minor, Lloyd B; Zee, David S

    2006-06-01

    The goal of this study was to assess how the axis of head rotation, Listing's law, and eye position influence the axis of eye rotation during brief, rapid head rotations. We specifically asked how the axis of eye rotation during the initial angular vestibuloocular reflex (VOR) changed when the pitch orientation of the head relative to Earth-vertical was varied, but the initial position of the eye in the orbit and the orientation of Listing's plane with respect to the head were fixed. We measured three-dimensional eye and head rotation axes in eight normal humans using the search coil technique during head-and-trunk (whole-body) and head-on-trunk (head-only) "impulses" about an Earth-vertical axis. The head was initially oriented at one of five pitch angles (30 degrees nose down, 15 degrees nose down, 0 degrees, 15 degrees nose up, 30 degrees nose up). The fixation target was always aligned with the nasooccipital axis. Whole-body impulses were passive, unpredictable, manual, rotations with peak-amplitude of approximately 20 degrees , peak-velocity of approximately 80 degrees /s, and peak-acceleration of approximately 1000 degrees /s2. Head-only impulses were also passive, unpredictable, manual, rotations with peak-amplitude of approximately 20 degrees , peak-velocity of approximately 150 degrees /s, and peak-acceleration of approximately 3000 degrees /s2. During whole-body impulses, the axis of eye rotation tilted in the same direction, and by an amount proportional (0.51 +/- 0.09), to the starting pitch head orientation (P rotation could be predicted from vectorial summation of the gains (eye velocity/head velocity) obtained for rotations about the pure yaw and roll head axes. Thus, even when the orientation of Listing's plane and eye position in the orbit are fixed, the axis of eye rotation during the VOR reflects a compromise between the requirements of Listing's law and a perfectly compensatory VOR.

  15. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Head Magnetic resonance imaging (MRI) of the head ... limitations of MRI of the Head? What is MRI of the Head? Magnetic resonance imaging (MRI) is ...

  16. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Head Magnetic resonance imaging (MRI) of the head uses a powerful ... Head? What is MRI of the Head? Magnetic resonance imaging (MRI) is a noninvasive medical test that ...

  17. Novel Electromyographic Protocols Using Axial Rotation and Cervical Flexion-Relaxation for the Assessment of Subjects With Neck Pain: A Feasibility Study.

    Science.gov (United States)

    DeVocht, James W; Gudavalli, Kalyani; Gudavalli, Maruti R; Xia, Ting

    2016-06-01

    The purpose of this study is to examine the feasibility of novel variations to the way cervical flexion-relaxation phenomenon (FRP) studies are conducted and the feasibility of using cervical axial rotation as an alternative objective measure of cervical pain/dysfunction. Electromyographic data were collected from cervical paraspinal muscles of 5 participants with neck pain and 5 asymptomatic controls. Cervical FRP was conducted as reported in the literature with the participants seated, except that they started with the head fully flexed instead of being erect. Data were also collected with participants laying prone, starting with their head hanging over the edge of the table. Additional data were collected from cervical paraspinal and sternocleidomastoid (SCM) muscles while the seated participants rotated their head fully to the right and left. Ratios were obtained for each type of test by dividing the electromyographic amplitude when muscles were most active by that when they were relaxed or in contralateral rotation. In each case, the ratio was higher for the controls than for those with neck pain, suggesting that any of the 4 methods could be used to distinguish between 2 groups. The ratios were most pronounced from SCMs during axial rotation. There appeared to be a negative relationship between pain level and the ratios obtained from each method. The findings from this small study are encouraging for all methods used, with axial rotation using SCMs appearing to be the most promising. These results indicate that larger, powered studies are warranted.

  18. A biomechanical study on the effects of rib head release on thoracic spinal motion.

    Science.gov (United States)

    Yao, Xianfeng; Blount, Thomas J; Suzuki, Nobumasa; Brown, Laura K; van der Walt, Christiaan J; Baldini, Todd; Lindley, Emily M; Patel, Vikas V; Burger, Evalina L

    2012-04-01

    Idiopathic scoliosis is generally treated by surgical derotation of the spine. A secondary goal of surgery is minimization of the "rib hump" deformity. Previous studies have evaluated the effects of surgical releases such as diskectomy, costo-vertebral joint release, facetectomy, and costoplasty on spine mobilization and overall contribution to thoracic stability. The present study was designed to evaluate the biomechanical effects of the rib head joints alone on axial rotation, lateral bending, and segmental rotation, without diskectomy or disruption of anterior or posterior elements. Four female cadaver thoracic spines with intact sternums and rib cages were mounted in an Instron servo-hydraulic bi-axial MTS. In a 12-step sequence, the costo-vertebral and costo-transverse ligaments were released, first unilaterally from T10-T7, then bilaterally until complete disarticulation between the rib heads and the vertebral bodies. After each release, biomechanical testing, including axial rotation and lateral bending, was performed. Vertebral body displacement was also measured using electromagnetic trackers. We found that rib displacement during axial rotation was significantly increased by unilateral rib head release, and torque was decreased with each successive cut. We also found increased vertebral displacement with sequential rib head release. Our results show that sequential costo-vertebral joint releases result in a decrease in the force required for axial rotation and lateral bending, coupled with an increase in the displacement of vertebral bodies. These findings suggest that surgical release of the costo-transverse and costo-vertebral ligaments can facilitate segmental correction in scoliosis by decreasing the torso's natural biomechanical resistance to this correction.

  19. [Bionic model for coordinated head-eye motion control].

    Science.gov (United States)

    Mao, Xiaobo; Chen, Tiejun

    2011-10-01

    The relationships between eye movements and head movements of the primate during gaze shifts are analyzed in detail in the present paper. Applying the mechanisms of neurophysiology to engineering domain, we have improved the robot eye-head coordination. A bionic control strategy of coordinated head-eye motion was proposed. The processes of gaze shifts are composed of an initial fast phase followed by a slow phase. In the fast phase saccade eye movements and slow head movements were combined, which cooperate to bring gaze from an initial resting position toward the new target rapidly, while in the slow phase the gaze stability and target fixation were ensured by the action of the vestibulo-ocular reflex (VOR) where the eyes and head rotate by equal amplitudes in opposite directions. A bionic gaze control model was given. The simulation results confirmed the effectiveness of the model by comparing with the results of neurophysiology experiments.

  20. Pigeons (C. livia Follow Their Head during Turning Flight: Head Stabilization Underlies the Visual Control of Flight

    Directory of Open Access Journals (Sweden)

    Ivo G. Ros

    2017-12-01

    Full Text Available Similar flight control principles operate across insect and vertebrate fliers. These principles indicate that robust solutions have evolved to meet complex behavioral challenges. Following from studies of visual and cervical feedback control of flight in insects, we investigate the role of head stabilization in providing feedback cues for controlling turning flight in pigeons. Based on previous observations that the eyes of pigeons remain at relatively fixed orientations within the head during flight, we test potential sensory control inputs derived from head and body movements during 90° aerial turns. We observe that periods of angular head stabilization alternate with rapid head repositioning movements (head saccades, and confirm that control of head motion is decoupled from aerodynamic and inertial forces acting on the bird's continuously rotating body during turning flapping flight. Visual cues inferred from head saccades correlate with changes in flight trajectory; whereas the magnitude of neck bending predicts angular changes in body position. The control of head motion to stabilize a pigeon's gaze may therefore facilitate extraction of important motion cues, in addition to offering mechanisms for controlling body and wing movements. Strong similarities between the sensory flight control of birds and insects may also inspire novel designs of robust controllers for human-engineered autonomous aerial vehicles.

  1. Pediatric head injury.

    Science.gov (United States)

    Tulipan, N

    1998-01-01

    Pediatric head injury is a public health problem that exacts a high price from patients, their families and society alike. While much of the brain damage in head-injured patients occurs at the moment of impact, secondary injuries can be prevented by aggressive medical and surgical intervention. Modern imaging devices have simplified the task of diagnosing intracranial injuries. Recent advances in monitoring technology have made it easier to assess the effectiveness of medical therapy. These include intracranial pressure monitoring devices that are accurate and safe, and jugular bulb monitoring which provides a continuous, qualitative measure of cerebral blood flow. The cornerstones of treatment remain hyperventilation and osmotherapy. Despite maximal treatment, however, the mortality and morbidity associated with pediatric head injury remains high. Reduction of this mortality and morbidity will likely depend upon prevention rather than treatment.

  2. Axial Lengths in Children with Recessive Cornea Plana.

    Science.gov (United States)

    Al Hazimi, Amro; Khan, Arif O

    2015-06-01

    While flat keratometry contributes to the hyperopia and associated refractive accommodative esotropia that is part of recessive cornea plana, whether or not axial lengths are abnormally short in the disease is unclear. In this study we assess this possibility. Prospective (2010-2012) axial length measurement (IOLmaster; Carl Zeiss, Oberkochen, Germany) of affected right eyes and comparison to right eyes with refractive accommodative esotropia only. Keratometry and refraction were also performed. For eight affected right eyes (age 10-12 years; seven families) axial length ranged from 21.46-24.80 mm (mean 23.34). Best corrected visual acuity ranged from 20/25 to 20/50, keratometry from 25.33-39.80 diopters (D) [mean 31.80], and refraction from +2.00 to +14.00 D (mean +7.22). For 50 control right eyes (age 4-12 years), axial length ranged from 19.87-23.66 mm (mean 21.6). Best-corrected visual acuity was 20/25 or better, keratometry ranged from 39.81-46.25 D (mean 42.42), and refraction from +2.25 to +8.00 D (mean 4.71). Axial lengths were longer in the affected group (2-tailed unpaired t-test p value 0.000005) despite greater hyperopia (2-tailed unpaired t-test p value 0.001). Despite greater hyperopia, axial lengths were longer in eyes with recessive cornea plana, evidence that axial lengths are not shortened by the disease. Keratometry in children with cornea plana was below the range of controls and was the major factor underlying the phenotype's hyperopia.

  3. Radiographic assessment of thoracolumbar fractures based on axial zones.

    Science.gov (United States)

    Baaj, Ali A; Gantwerker, Brian R; Theodore, Nicholas; Uribe, Juan S; Vale, Fernando L; Crawford, Neil R; Sonntag, Volker K H

    2014-04-01

    Retrospective study of computed tomography imaging of patients with thoracolumbar (TL) fractures. To propose an axial model of spinal fractures based on the osteoligamentous continuity of the TL spinal segments in the axial plane and to determine the correlation between the 3-column theory and the proposed axial zone model. Predicting spinal instability of TL fractures is based on several radiologic and clinical parameters. Efforts to refine fracture classification schemes to better predict instability continue. Computed tomography scans of 229 consecutive patients who presented with TL fractures between March 2005 and April 2007 were reviewed. TL fractures were classified according to both the Denis 3-column theory and the proposed axial zone model. The incidence of column and axial zone injuries was determined. On the basis of these results, a treatment algorithm was developed. Zone disruption in surgical fractures was distributed as follows: 24 (96%) involved zone A, 25 (100%) involved zone B, 17 (68%) involved zone C, and 15 (60%) involved zone D. All surgical fractures involved 2 or more zones. Zone B was involved in all surgical fractures. The likelihood of surgical intervention increased as the number of zones increased, especially if the injury was a 2-column or 3-column injury. The current 3-column theory of spinal stability does not account for the axial component of an injury. Application of our proposed "axial zone model" may enhance the ability to predict stability, depending not only on the number of columns, but also on the number of zones involved in the injuries. Further clinical and biomechanical studies are warranted to validate this model.

  4. Improvement of Axial Reflector Cross Section Generation Model for PWR Core Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Shim, Cheon Bo; Lee, Kyung Hoon; Cho, Jin Young [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    This paper covers the study for improvement of axial reflector XS generation model. In the next section, the improved 1D core model is represented in detail. Reflector XS generated by the improved model is compared to that of the conventional model in the third section. Nuclear design parameters generated by these two XS sets are also covered in that section. Significant of this study is discussed in the last section. Two-step procedure has been regarded as the most practical approach for reactor core designs because it offers core design parameters quite rapidly within acceptable range. Thus this approach is adopted for SMART (System-integrated Modular Advanced Reac- Tor) core design in KAERI with the DeCART2D1.1/ MASTER4.0 (hereafter noted as DeCART2D/ MASTER) code system. Within the framework of the two-step procedure based SMART core design, various researches have been studied to improve the core design reliability and efficiency. One of them is improvement of reflector cross section (XS) generation models. While the conventional FA/reflector two-node model used for most core designs to generate reflector XS cannot consider the actual configuration of fuel rods that intersect at right angles to axial reflectors, the revised model reflects the axial fuel configuration by introducing the radially simplified core model. The significance of the model revision is evaluated by observing HGC generated by DeCART2D, reflector XS, and core design parameters generated by adopting the two models. And it is verified that about 30 ppm CBC error can be reduced and maximum Fq error decreases from about 6 % to 2.5 % by applying the revised model. Error of AO and axial power shapes are also reduced significantly. Therefore it can be concluded that the simplified 1D core model improves the accuracy of the axial reflector XS and leads to the two-step procedure reliability enhancement. Since it is hard for core designs to be free from the two-step approach, it is necessary to find

  5. Development of a screening MRI for infants at risk for abusive head trauma

    Energy Technology Data Exchange (ETDEWEB)

    Flom, Lynda; Panigrahy, Ashok [Children' s Hospital of Pittsburgh of UPMC, Department of Radiology, Pittsburgh, PA (United States); Fromkin, Janet [University of Pittsburgh, Department of Pediatrics, Children' s Hospital of Pittsburgh of UPMC, Pittsburgh, PA (United States); Tyler-Kabara, Elizabeth [University of Pittsburgh, Department of Neurosurgery, Children' s Hospital of Pittsburgh of UPMC, McGowan Institute for Regenerative Medicine, Pittsburgh, PA (United States); Berger, Rachel P. [University of Pittsburgh, Department of Pediatrics, Children' s Hospital of Pittsburgh of UPMC, Pittsburgh, PA (United States); University of Pittsburgh, Safar Center for Resuscitation Research, Pittsburgh, PA (United States)

    2016-04-15

    Abusive head trauma (AHT) is an important cause of morbidity in infants. Identifying which well-appearing infants are at risk for AHT and need neuroimaging is challenging, and concern about radiation exposure limits the use of head CT. Availability of an MRI protocol that is highly sensitive for intracranial hemorrhage would allow for AHT screening of well-appearing infants without exposing them to radiation. To develop a screening MRI protocol to identify intracranial hemorrhage in well-appearing infants at risk for AHT. Infants enrolled in a parent study of well-appearing infants at increased risk for AHT were eligible for the current study if they underwent both head CT and conventional brain MRI. A derivation cohort of nine infants with AHT was used to identify sequences that provided the highest sensitivity for intracranial hemorrhage. A validation cohort of 78 infants including both controls with normal neuroimaging and cases with AHT was used to evaluate the accuracy of the selected sequences. Three pulse sequences - axial T2, axial gradient recalled echo (GRE) and coronal T1-W inversion recovery - were 100% sensitive for intracranial hemorrhage in the derivation cohort. The same sequences were 100% sensitive (25/25) and 83% specific (44/53) for intracranial hemorrhage in the validation cohort. A screening MRI protocol including axial T2, axial GRE and coronal T1-W inversion recovery sequences is highly sensitive for intracranial hemorrhage and may be useful as a screening tool to differentiate well-appearing infants at risk for AHT who should undergo head CT from those who can safely be discharged without head CT. Additional research is needed to evaluate the feasibility of this approach in clinical practice. (orig.)

  6. Head First Statistics

    CERN Document Server

    Griffiths, Dawn

    2009-01-01

    Wouldn't it be great if there were a statistics book that made histograms, probability distributions, and chi square analysis more enjoyable than going to the dentist? Head First Statistics brings this typically dry subject to life, teaching you everything you want and need to know about statistics through engaging, interactive, and thought-provoking material, full of puzzles, stories, quizzes, visual aids, and real-world examples. Whether you're a student, a professional, or just curious about statistical analysis, Head First's brain-friendly formula helps you get a firm grasp of statistics

  7. Head and Neck Reconstruction.

    Science.gov (United States)

    Wong, Shannon; Melin, Alyson; Reilly, Debra

    2017-10-01

    Management of head and neck burns involves acute and intermediate phases. Acutely, the goals are establish a secure airway and treat life-threatening injuries. Then, optimize nutrition, assess extent of the burn, perform local wound care, and provide eye protection. Management depends on the degree of the head and neck burn. Postinjury splinting and rehabilitation are vital to healing. After the acute inflammation has resolved and the scars have matured, reconstruction begins with the goals of restoring both function and aesthetics. Reconstruction ranges from simple scar release, to skin grafting, and possibly free flap reconstruction. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Head first Ajax

    CERN Document Server

    Riordan, Rebecca M

    2008-01-01

    Ajax is no longer an experimental approach to website development, but the key to building browser-based applications that form the cornerstone of Web 2.0. Head First Ajax gives you an up-to-date perspective that lets you see exactly what you can do -- and has been done -- with Ajax. With it, you get a highly practical, in-depth, and mature view of what is now a mature development approach. Using the unique and highly effective visual format that has turned Head First titles into runaway bestsellers, this book offers a big picture overview to introduce Ajax, and then explores the use of ind

  9. Three-dimensional innate mobility of the human foot bones under axial loading using biplane X-ray fluoroscopy.

    Science.gov (United States)

    Ito, Kohta; Hosoda, Koh; Shimizu, Masahiro; Ikemoto, Shuhei; Nagura, Takeo; Seki, Hiroyuki; Kitashiro, Masateru; Imanishi, Nobuaki; Aiso, Sadakazu; Jinzaki, Masahiro; Ogihara, Naomichi

    2017-10-01

    The anatomical design of the human foot is considered to facilitate generation of bipedal walking. However, how the morphology and structure of the human foot actually contribute to generation of bipedal walking remains unclear. In the present study, we investigated the three-dimensional kinematics of the foot bones under a weight-bearing condition using cadaver specimens, to characterize the innate mobility of the human foot inherently prescribed in its morphology and structure. Five cadaver feet were axially loaded up to 588 N (60 kgf), and radiographic images were captured using a biplane X-ray fluoroscopy system. The present study demonstrated that the talus is medioinferiorly translated and internally rotated as the calcaneus is everted owing to axial loading, causing internal rotation of the tibia and flattening of the medial longitudinal arch in the foot. Furthermore, as the talus is internally rotated, the talar head moves medially with respect to the navicular, inducing external rotation of the navicular and metatarsals. Under axial loading, the cuboid is everted simultaneously with the calcaneus owing to the osseous locking mechanism in the calcaneocuboid joint. Such detailed descriptions about the innate mobility of the human foot will contribute to clarifying functional adaptation and pathogenic mechanisms of the human foot.

  10. Dynamic Behaviours of a Single Soft Rock-Socketed Shaft Subjected to Axial Cyclic Loading

    Directory of Open Access Journals (Sweden)

    Ben-jiao Zhang

    2016-01-01

    Full Text Available The soft rock was simulated by cement, plaster, sand, water, and concrete hardening accelerator in this paper. Meanwhile, uniaxial compressive strength tests and triaxial compression tests were conducted to study the mechanical properties of simulated soft rock samples. Model tests on a single pile socketed in simulated soft rock under axial cyclic loading were conducted by using a device which combined test apparatus with a GCTS dynamic triaxial system. Test results show that the optimal mix ratio is cement : plaster : medium sand : water : concrete hardening accelerator = 4.5% : 5.0% : 84.71% : 4.75% : 1.04%. The static load ratio (SLR, cyclic load ratio (CLR, and the number of cycles affect the accumulated deformation and cyclic secant modulus of the pile head. The accumulated deformation increases with increasing numbers of cycles. However, the cyclic secant modulus of pile head increases and then decreases with the growth in the number of cycles and finally remains stable after 50 cycles. According to the test results, the development of accumulated settlement was analysed. Finally, an empirical formula for accumulated settlement, considering the effects of the number of cycles, the static load ratio, the cyclic load ratio, and the uniaxial compressive strength, is proposed which can be used for feasibility studies or preliminary design of pile foundations on soft rock subjected to traffic loading.

  11. Counter-rotating type axial flow pump unit in turbine mode for micro grid system

    Science.gov (United States)

    Kasahara, R.; Takano, G.; Murakami, T.; Kanemoto, T.; Komaki, K.

    2012-11-01

    Traditional type pumped storage system contributes to adjust the electric power unbalance between day and night, in general. This serial research proposes the hybrid power system combined the wind power unit with the pump-turbine unit, to provide the constant output for the grid system, even at the suddenly fluctuating/turbulent wind. In the pumping mode, the pump should operate unsteadily at not only the normal but also the partial discharge. The operation may be unstable in the rising portion of the head characteristics at the lower discharge, and/or bring the cavitation at the low suction head. To simultaneously overcome both weak points, the authors have proposed a superior pump unit that is composed of counter-rotating type impellers and a peculiar motor with double rotational armatures. This paper discusses the operation at the turbine mode of the above unit. It is concluded with the numerical simulations that this type unit can be also operated acceptably at the turbine mode, because the unit works so as to coincide the angular momentum change through the front runners/impellers with that thorough the rear runners/impellers, namely to take the axial flow at not only the inlet but also the outlet without the guide vanes.

  12. Effects of fluid viscoelasticity on the performance of an axial blood pump model.

    Science.gov (United States)

    Hu, Qi-Hui; Li, Jing-Yin; Zhang, Ming-Yuan

    2012-01-01

    An aqueous Xanthan gum solution (XGS) was used as blood analog fluid to explore the influence of fluid viscoelasticity on the performance of an axial blood pump model. For comparison, a 39 wt% Newtonian aqueous glycerin solution (GS), the common fluid in blood pump tests, was also used as a working fluid. The experimental results showed that a higher head curve was obtained using XGS in the pump than using GS. The heads of the XGS that were computed using the viscoelastic turbulence model agreed well with the measured data. In contrast, the standard k-ε turbulence model failed to provide satisfactory predictions for the XGS. The computational results revealed that in most parts of the pump model flow fields, the Reynolds shear stress values and turbulent dissipation rates of the XGS were all lower than those of the GS. The hemolysis index of the pump model using the XGS was calculated to be only one-third of that using the GS.

  13. The window of opportunity: a relevant concept for axial spondyloarthritis.

    Science.gov (United States)

    Robinson, Philip C; Brown, Matthew A

    2014-01-01

    The window of opportunity is a concept critical to rheumatoid arthritis treatment. Early treatment changes the outcome of rheumatoid arthritis treatment, in that response rates are higher with earlier disease-modifying anti-rheumatic drug treatment and damage is substantially reduced. Axial spondyloarthritis is an inflammatory axial disease encompassing both nonradiographic axial spondyloarthritis and established ankylosing spondylitis. In axial spondyloarthritis, studies of magnetic resonance imaging as well as tumor necrosis factor inhibitor treatment and withdrawal studies all suggest that early effective suppression of inflammation has the potential to reduce radiographic damage. This potential would suggest that the concept of a window of opportunity is relevant not only to rheumatoid arthritis but also to axial spondyloarthritis. The challenge now remains to identify high-risk patients early and to commence treatment without delay. Developments in risk stratification include new classification criteria, identification of clinical risk factors, biomarkers, genetic associations, potential antibody associations and an ankylosing spondylitis-specific microbiome signature. Further research needs to focus on the evidence for early intervention and the early identification of high-risk individuals.

  14. Development and Testing of an Axial Halbach Magnetic Bearing

    Science.gov (United States)

    Eichenberg, Dennis J.; Gallo, Christopher A.; Thompson, William K.

    2006-01-01

    The NASA Glenn Research Center has developed and tested a revolutionary Axial Halbach Magnetic Bearing. The objective of this work is to develop a viable non-contact magnetic thrust bearing utilizing Halbach arrays for all-electric flight, and many other applications. This concept will help to reduce harmful emissions, reduce the Nation s dependence on fossil fuels and mitigate many of the concerns and limitations encountered in conventional axial bearings such as bearing wear, leaks, seals and friction loss. The Axial Halbach Magnetic Bearing is inherently stable and requires no active feedback control system or superconductivity as required in many magnetic bearing designs. The Axial Halbach Magnetic Bearing is useful for very high speed applications including turbines, instrumentation, medical systems, computer memory systems, and space power systems such as flywheels. Magnetic fields suspend and support a rotor assembly within a stator. Advanced technologies developed for particle accelerators, and currently under development for maglev trains and rocket launchers, served as the basis for this application. Experimental hardware was successfully designed and developed to validate the basic principles and analyses. The report concludes that the implementation of Axial Halbach Magnetic Bearings can provide significant improvements in rotational system performance and reliability.

  15. Axial Instability of Coating Flow in a Horizontal Rotating Cylinder

    Science.gov (United States)

    Hosoi, A. E.; Mahadevan, L.

    1997-11-01

    We investigate the axial instability of the free-surface of a viscous fluid in a horizontal cylinder rotating about its major axis. At low rotation rates, the shape of the free-surface appears to be determined by the balance between gravitational and viscous forces. Following earlier work (Benjamin, Pritchard and Tavener), we use an asymptotic expansion in the small parameter α = √Ω ν \\over g R where ν is viscosity, Ω is angular velocity, g is gravity and R is the radius of the cylinder, to derive a simplified evolution equation for the free-surface. This equation is solved numerically to determine the base state with no axial variation, which is then perturbed to examine the onset of unstable axial modes. Various computational results will be presented for the shape of the free-surface and the wavelength of the axial instability. We show that inertia plays an important role in the onset of the instability and we derive the power law λ = γ^1/3 where λ is the wavelength of the axial instability and γ is surface tension.

  16. Light weakly coupled axial forces: models, constraints, and projections

    Science.gov (United States)

    Kahn, Yonatan; Krnjaic, Gordan; Mishra-Sharma, Siddharth; Tait, Tim M. P.

    2017-05-01

    We investigate the landscape of constraints on MeV-GeV scale, hidden U(1) forces with nonzero axial-vector couplings to Standard Model fermions. While the purely vector-coupled dark photon, which may arise from kinetic mixing, is a well-motivated scenario, several MeV-scale anomalies motivate a theory with axial couplings which can be UV-completed consistent with Standard Model gauge invariance. Moreover, existing constraints on dark photons depend on products of various combinations of axial and vector couplings, making it difficult to isolate the effects of axial couplings for particular flavors of SM fermions. We present a representative renormalizable, UV-complete model of a dark photon with adjustable axial and vector couplings, discuss its general features, and show how some UV constraints may be relaxed in a model with nonrenormalizable Yukawa couplings at the expense of fine-tuning. We survey the existing parameter space and the projected reach of planned experiments, briefly commenting on the relevance of the allowed parameter space to low-energy anomalies in π0 and 8Be∗ decay.

  17. Continuous millennial decrease of the Earth's magnetic axial dipole

    Science.gov (United States)

    Poletti, Wilbor; Biggin, Andrew J.; Trindade, Ricardo I. F.; Hartmann, Gelvam A.; Terra-Nova, Filipe

    2018-01-01

    Since the establishment of direct estimations of the Earth's magnetic field intensity in the first half of the nineteenth century, a continuous decay of the axial dipole component has been observed and variously speculated to be linked to an imminent reversal of the geomagnetic field. Furthermore, indirect estimations from anthropologically made materials and volcanic derivatives suggest that this decrease began significantly earlier than direct measurements have been available. Here, we carefully reassess the available archaeointensity dataset for the last two millennia, and show a good correspondence between direct (observatory/satellite) and indirect (archaeomagnetic) estimates of the axial dipole moment creating, in effect, a proxy to expand our analysis back in time. Our results suggest a continuous linear decay as the most parsimonious long-term description of the axial dipole variation for the last millennium. We thus suggest that a break in the symmetry of axial dipole moment advective sources occurred approximately 1100 years earlier than previously described. In addition, based on the observed dipole secular variation timescale, we speculate that the weakening of the axial dipole may end soon.

  18. Amphiregulin Antibody and Reduction of Axial Elongation in Experimental Myopia

    Directory of Open Access Journals (Sweden)

    Wen Jun Jiang

    2017-03-01

    Full Text Available To examine the mechanism of ocular axial elongation in myopia, guinea pigs (age: 2–3 weeks which either underwent unilateral or bilateral lens-induced myopization (group 1 or which were primarily myopic at baseline (group 2 received unilateral intraocular injections of amphiregulin antibody (doses: 5, 10, or 15 μg three times in intervals of 9 days. A third group of emmetropic guinea pigs got intraocular unilateral injections of amphiregulin (doses: 0.25, 0.50 or 1.00 ng, respectively. In each group, the contralateral eyes received intraocular injections of Ringer's solution. In intra-animal inter-eye comparison and intra-eye follow-up comparison in groups 1 and 2, the study eyes as compared to the contralateral eyes showed a dose-dependent reduction in axial elongation. In group 3, study eyes and control eyes did not differ significantly in axial elongation. Immunohistochemistry revealed amphiregulin labelling at the retinal pigment epithelium in eyes with lens-induced myopization and Ringer's solution injection, but not in eyes with amphiregulin antibody injection. Intraocular injections of amphiregulin-antibody led to a reduction of lens-induced axial myopic elongation and of the physiological eye enlargement in young guinea pigs. In contrast, intraocularly injected amphiregulin in a dose of ≤1 ng did not show a significant effect. Amphiregulin may be one of several essential molecular factors for axial elongation.

  19. Method to measure tone of axial and proximal muscle.

    Science.gov (United States)

    Gurfinkel, Victor S; Cacciatore, Timothy W; Cordo, Paul J; Horak, Fay B

    2011-12-14

    The control of tonic muscular activity remains poorly understood. While abnormal tone is commonly assessed clinically by measuring the passive resistance of relaxed limbs, no systems are available to study tonic muscle control in a natural, active state of antigravity support. We have developed a device (Twister) to study tonic regulation of axial and proximal muscles during active postural maintenance (i.e. postural tone). Twister rotates axial body regions relative to each other about the vertical axis during stance, so as to twist the neck, trunk or hip regions. This twisting imposes length changes on axial muscles without changing the body's relationship to gravity. Because Twister does not provide postural support, tone must be regulated to counteract gravitational torques. We quantify this tonic regulation by the restive torque to twisting, which reflects the state of all muscles undergoing length changes, as well as by electromyography of relevant muscles. Because tone is characterized by long-lasting low-level muscle activity, tonic control is studied with slow movements that produce "tonic" changes in muscle length, without evoking fast "phasic" responses. Twister can be reconfigured to study various aspects of muscle tone, such as co-contraction, tonic modulation to postural changes, tonic interactions across body segments, as well as perceptual thresholds to slow axial rotation. Twister can also be used to provide a quantitative measurement of the effects of disease on axial and proximal postural tone and assess the efficacy of intervention.

  20. Modeling effects of axial extension on arterial growth and remodeling.

    Science.gov (United States)

    Valentín, Arturo; Humphrey, Jay D

    2009-09-01

    Diverse mechanical perturbations elicit arterial growth and remodeling responses that appear to optimize structure and function so as to promote mechanical homeostasis. For example, it is well known that functional adaptations to sustained changes in transmural pressure and blood flow primarily affect wall thickness and caliber to restore circumferential and wall shear stresses toward normal. More recently, however, it has been shown that changes in axial extension similarly prompt dramatic cell and matrix reorganization and turnover, resulting in marked changes in unloaded geometry and mechanical behavior that presumably restore axial stress toward normal. Because of the inability to infer axial stress from in vivo measurements, simulations are needed to examine this hypothesis and to guide the design of future experiments. In this paper, we show that a constrained mixture model predicts salient features of observed responses to step increases in axial extension, including marked increases in fibrous constituent production, leading to a compensatory lengthening that restores original mechanical behavior. Because axial extension can be modified via diverse surgical procedures, including bypass operations, and exploited in tissue regeneration research, there is a need for increased attention to this important aspect of arterial biomechanics and mechanobiology.

  1. Method to Measure Tone of Axial and Proximal Muscle

    Science.gov (United States)

    Gurfinkel, Victor S.; Cacciatore, Timothy W.; Cordo, Paul J.; Horak, Fay B.

    2011-01-01

    The control of tonic muscular activity remains poorly understood. While abnormal tone is commonly assessed clinically by measuring the passive resistance of relaxed limbs1, no systems are available to study tonic muscle control in a natural, active state of antigravity support. We have developed a device (Twister) to study tonic regulation of axial and proximal muscles during active postural maintenance (i.e. postural tone). Twister rotates axial body regions relative to each other about the vertical axis during stance, so as to twist the neck, trunk or hip regions. This twisting imposes length changes on axial muscles without changing the body's relationship to gravity. Because Twister does not provide postural support, tone must be regulated to counteract gravitational torques. We quantify this tonic regulation by the restive torque to twisting, which reflects the state of all muscles undergoing length changes, as well as by electromyography of relevant muscles. Because tone is characterized by long-lasting low-level muscle activity, tonic control is studied with slow movements that produce "tonic" changes in muscle length, without evoking fast "phasic" responses. Twister can be reconfigured to study various aspects of muscle tone, such as co-contraction, tonic modulation to postural changes, tonic interactions across body segments, as well as perceptual thresholds to slow axial rotation. Twister can also be used to provide a quantitative measurement of the effects of disease on axial and proximal postural tone and assess the efficacy of intervention. PMID:22214974

  2. Rotordynamics of Turbine Labyrinth Seals with Rotor Axial Shifting

    Directory of Open Access Journals (Sweden)

    2006-01-01

    Full Text Available Rotors in high-performance steam turbines experience a significant axial shifting during starting and stopping processes due to thermal expansion, for example. This axial shifting could significantly alter the flow pattern and the flow-induced rotordynamic forces in labyrinth seals, which in turn, can considerably affect the rotor-seal system performance. This paper investigates the influence of the rotor axial shifting on leakage rate as well as rotordynamic forces in high-low labyrinth seals over a range of seal clearances and inlet swirl velocities. A well-established CFD-perturbation model was employed to predict the rotordynamic coefficients. A surprisingly large effect was detected for rotordynamic characteristics due to rotor shifting. It was also found that a less destabilizing effect arose from rotor axial shifting in the leakage flow direction, whereas a more destabilizing effect arose from shifting against the leakage flow direction. Further, a tentative explanation was proposed for the large sensitivities of dynamic forces to rotor axial shifting.

  3. External hydrocephalus (benign extra-axial collections of infancy) - review of 15 cases; Hidrocefalia externa colecao extra-axial benigna da infancia - revisao de 15 casos

    Energy Technology Data Exchange (ETDEWEB)

    Machado Junior, Marcos Alberto da Costa; Matos, Paulo Engracio de; Barbosa, Veronica Aline [Fundacao Monte Tabor, Salvador, BA (Brazil). Hospital Sao Rafael. Servico de Bioimagem; Vieira, Naiara Argollo [Hospital Salvador, BA (Brazil); Vieira, Lauro Conceicao Nascimento [Fundacao Monte Tabor, Salvador, BA (Brazil). Hospital Sao Rafael. Servico de Ressonancia Magnetica; Puglio, Nadja; Bacelar, Aroldo [Fundacao Monte Tabor, Salvador, BA (Brazil). Hospital Sao Rafael

    1997-03-01

    The authors studied 15 cases of external hydrocephalus over a 7-year period (September 1987 to May 1995). External hydrocephalus is a condition in which infants with rapidly enlarging heads are found to have a MRI showing widening of subarachnoid space with mild or no ventricular dilatation. Some of the MRI were compared with those of patients with cerebral atrophy and some etiopathogenic hypothesis are presented. These findings indicate that external hydrocephalus is an age-related self-limited condition occurring in infants with open cranial sutures and that it usually resolves without intervention after the second or third year of age. (author) 21 refs., 4 figs.

  4. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos ... head injuries, stroke , brain tumors and other brain diseases than regular radiographs (x-rays). top of page ...

  5. Lubricating the swordfish head

    NARCIS (Netherlands)

    Videler, John J.; Haydar, Deniz; Snoek, Roelant; Hoving, Henk-Jan T.; Szabo, Ben G.

    The swordfish is reputedly the fastest swimmer on Earth. The concave head and iconic sword are unique characteristics, but how they contribute to its speed is still unknown. Recent computed tomography scans revealed a poorly mineralised area near the base of the rostrum. Here we report, using

  6. Waco Head Start Program.

    Science.gov (United States)

    Porter, Para

    The Economic Opportunity Act of 1964 led to the formation of three separate Head Start Programs in Waco, Texas. The first year, 1,500 children were involved. Of these, 40 percent were Negro, 30 percent Latin American, and 30 percent white. All teachers received a week of preparatory study at the University of Texas. The program involved four areas…

  7. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Computed Tomography (CT) - Head ...

  8. Ultrasound: Head (For Parents)

    Science.gov (United States)

    ... a safe and painless test that uses sound waves to make images of the brain. During the examination, an ultrasound machine sends sound ... The fontanel provides an opening for the sound waves to get through and reach the brain. Why It's Done Doctors order head ultrasounds when ...

  9. Silva as the Head

    DEFF Research Database (Denmark)

    Svabo, Connie

    2015-01-01

    The head of the performance design programme is substituted by a sister's academy delegate. this performance situation formed part of a week of semesterstart where the students and professors visited Sister's Academy, Malmø. I participated in the Sister's Academy as visiting researcher and here...

  10. Computed Tomography (CT) -- Head

    Medline Plus

    Full Text Available ... full size with caption Pediatric Content Some imaging tests and treatments have special pediatric considerations. The teddy bear denotes child-specific content. Related Articles and Media Radiation Dose in X-Ray and CT Exams Blood Clots CT Perfusion of the Head CT Angiography ( ...

  11. Head nurses as middle managers.

    Science.gov (United States)

    Johnston, P F

    1983-11-01

    The relationship between head nurses and their staff nurses influences staff turnover rates and job satisfaction. In this article the author describes the measures taken by the management of Greater Southeast Community Hospital in response to an increasing turnover rate among staff RNs. In recognition of the head nurse role vis-d-vis attrition rates and job satisfaction, head nurses were upgraded to department head status and rigorous head nurse performance standards were developed. These standards required clinical expertise, managerial competence, and accountability. It is the author's contention that clinical practice and staff morale are directly related to a clearly defined head nurse role.

  12. Head injuries, heading, and the use of headgear in soccer.

    Science.gov (United States)

    Niedfeldt, Mark W

    2011-01-01

    Soccer has more than 265 million players around the world and is the only contact sport with purposeful use of the head for controlling and advancing the ball. Head contact in soccer has the potential to cause acute traumatic brain injury including concussion or, potentially, a pattern of chronic brain injury. Although early retrospective research on the effects of soccer heading seemed to suggest that purposeful heading may contribute to long-term cognitive impairment, prospective controlled studies do not support this and, in fact, suggest that purposeful heading may not be a risk factor for cognitive impairment. Headgear has not been shown to be effective in reducing ball impact but may be helpful in reducing the force of non-ball-related impacts to the head. There are concerns that universal use of headgear may cause more aggressive heading and head challenges, leading to increased risk of injury.

  13. Radial Head Fractures

    Science.gov (United States)

    Jordan, Robert W.; Jones, Alistair DR.

    2017-01-01

    Background: Radial head fractures are common elbow injuries in adults and are frequently associated with additional soft tissue and bone injuries. Methods: A literature search was performed and the authors’ personal experiences are reported. Results: Mason type I fractures are treated non-operatively with splinting and early mobilisation. The management of Mason type II injuries is less clear with evidence supporting both non-operative treatment and internal fixation. The degree of intra-articular displacement and angulation acceptable for non-operative management has yet to be conclusively defined. Similarly the treatment of type III and IV fractures remain controversial. Traditional radial head excision is associated with valgus instability and should be considered only for patients with low functional demands. Comparative studies have shown improved results from internal fixation over excision. Internal fixation should only be attempted when anatomic reduction and initiation of early motion can be achieved. Authors have reported that results from fixation are poorer and complication rates are higher if more than three fragments are present. Radial head arthroplasty aims to reconstruct the native head and is indicated when internal fixation is not feasible and in the presence of complex elbow injuries. Overstuffing of the radiocapitellar joint is a frequent technical fault and has significant adverse effects on elbow biomechanics. Modular design improves the surgeon’s ability to reconstruct the native joint. Two randomised controlled trials have shown improved clinical outcomes and lower complication rate following arthroplasty when compared to internal fixation. Conclusion: We have presented details regarding the treatment of various types of radial head fractures - further evidence, however, is still required to provide clarity over the role of these different management strategies. PMID:29290880

  14. Reactor vessel lower head integrity

    Energy Technology Data Exchange (ETDEWEB)

    Rubin, A.M.

    1997-02-01

    On March 28, 1979, the Three Mile Island Unit 2 (TMI-2) nuclear power plant underwent a prolonged small break loss-of-coolant accident that resulted in severe damage to the reactor core. Post-accident examinations of the TMI-2 reactor core and lower plenum found that approximately 19,000 kg (19 metric tons) of molten material had relocated onto the lower head of the reactor vessel. Results of the OECD TMI-2 Vessel Investigation Project concluded that a localized hot spot of approximately 1 meter diameter had existed on the lower head. The maximum temperature on the inner surface of the reactor pressure vessel (RPV) in this region reached 1100{degrees}C and remained at that temperature for approximately 30 minutes before cooling occurred. Even under the combined loads of high temperature and high primary system pressure, the TMI-2 RPV did not fail. (i.e. The pressure varied from about 8.5 to 15 MPa during the four-hour period following the relocation of melt to the lower plenum.) Analyses of RPV failure under these conditions, using state-of-the-art computer codes, predicted that the RPV should have failed via local or global creep rupture. However, the vessel did not fail; and it has been hypothesized that rapid cooling of the debris and the vessel wall by water that was present in the lower plenum played an important role in maintaining RPV integrity during the accident. Although the exact mechanism(s) of how such cooling occurs is not known, it has been speculated that cooling in a small gap between the RPV wall and the crust, and/or in cracks within the debris itself, could result in sufficient cooling to maintain RPV integrity. Experimental data are needed to provide the basis to better understand these phenomena and improve models of RPV failure in severe accident codes.

  15. Molecular dynamics study on resonance frequency change due to axial-strain-induced torsions of single-walled carbon nanotubes

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Jeong Won, E-mail: jwkang@cjnu.ac.k [Department of Computer Engineering, Chungju National University, Chungju 380-702 (Korea, Republic of); Kim, Ki-Sub, E-mail: kks1114@cjnu.ac.k [Department of Chemical and Biological Engineering, Chungju National University, Chungju 380-702 (Korea, Republic of); Byun, Ki Ryang [School of Electrical and Electronic Engineering, Chung-Ang University, Seoul 156-756 (Korea, Republic of); Hwang, Ho Jung, E-mail: hjhwang@cau.ac.k [School of Electrical and Electronic Engineering, Chung-Ang University, Seoul 156-756 (Korea, Republic of)

    2011-03-21

    We investigated, via the classical MD simulation method based on Tersoff-Brenner potential, the fundamental resonance frequency changes of single-walled carbon nanotube (SWCNT) resonators originated from the purely mechanical coupling of the axial-strain-induced torsion (ASIT) response. The fundamental frequency changes were also negligible where the ASIT responses were negligible in achiral SWCNTs whereas those were explicitly found under both compression and tension for the chiral SWCNTs with the obvious ASIT responses. Specially, for SWCNT with the chiral angle of {pi}/12, where the highest ASIT response can be found, the fundamental resonance frequency changes were highest. The fundamental resonance frequencies under the tensioning increased almost linearly with increasing the axial strain whereas they rapidly decreased under compression with increasing the compressive strain. - Research highlights: Frequency changes of nanotube resonators due to the axial-strain-induced torsion. Resonant frequency changes were highest for nanotube with the chiral angle of {pi}/12. Resonant frequencies under tensioning increase linearly with increasing the strain. Resonant frequencies rapidly decrease with increasing the compression.

  16. Axially modulated arch resonator for logic and memory applications

    KAUST Repository

    Hafiz, Md Abdullah Al

    2018-01-17

    We demonstrate reconfigurable logic and random access memory devices based on an axially modulated clamped-guided arch resonator. The device is electrostatically actuated and the motional signal is capacitively sensed, while the resonance frequency is modulated through an axial electrostatic force from the guided side of the microbeam. A multi-physics finite element model is used to verify the effectiveness of the axial modulation. We present two case studies: first, a reconfigurable two-input logic gate based on the linear resonance frequency modulation, and second, a memory element based on the hysteretic frequency response of the resonator working in the nonlinear regime. The energy consumptions of the device for both logic and memory operations are in the range of picojoules, promising for energy efficient alternative computing paradigm.

  17. Defining active sacroiliitis on MRI for classification of axial spondyloarthritis

    DEFF Research Database (Denmark)

    Lambert, Robert G W; Bakker, Pauline A C; van der Heijde, Désirée

    2016-01-01

    OBJECTIVES: To review and update the existing definition of a positive MRI for classification of axial spondyloarthritis (SpA). METHODS: The Assessment in SpondyloArthritis International Society (ASAS) MRI working group conducted a consensus exercise to review the definition of a positive MRI...... for inclusion in the ASAS classification criteria of axial SpA. Existing definitions and new data relevant to the MRI diagnosis and classification of sacroiliitis and spondylitis in axial SpA, published since the ASAS definition first appeared in print in 2009, were reviewed and discussed. The precise wording...... of the existing definition was examined in detail and the data and a draft proposal were presented to and voted on by the ASAS membership. RESULTS: The clear presence of bone marrow oedema on MRI in subchondral bone is still considered to be the defining observation that determines the presence of active...

  18. In vivo classification of breast masses using features derived from axial-strain and axial-shear images.

    Science.gov (United States)

    Xu, Haiyan; Varghese, Tomy; Jiang, Jingfeng; Zagzebski, James A

    2012-10-01

    Breast cancer is currently the second leading cause of cancer deaths in women. Early detection and accurate classification of suspicious masses as benign or malignant is important for arriving at an appropriate treatment plan. In this article, we present classification results for features extracted from ultrasound-based, axial-strain and axial-shear images of breast masses. The breast-mass stiffness contrast, size ratio, and a normalized axial-shear strain area feature are evaluated for the classification of in vivo breast masses using a leave-one-out classifier. Radiofrequency echo data from 123 patients were acquired using Siemens Antares or Elegra clinical ultrasound systems during freehand palpation. Data from four different institutions were analyzed. Axial displacements and strains were estimated using a multilevel, pyramid-based two-dimensional cross-correlation algorithm, with final processing block dimensions of 0.385 mm × 0.507 mm (three A-lines). Since mass boundaries on B-mode images for 21 patients could not be delineated (isoechoic), the combined feature analysis was only performed for 102 patients. Results from receiver operating characteristic (ROC) demonstrate that the area under the curve was 0.90, 0.84, and 0.52 for the normalized axial-shear strain, size ratio, and stiffness contrast, respectively. When these three features were combined using a leave-one-out classifier and support vector machine approach, the overall area under the curve improved to 0.93.

  19. Spectral analysis in thin tubes with axial heterogeneities

    KAUST Repository

    Ferreira, Rita

    2015-01-01

    In this paper, we present the 3D-1D asymptotic analysis of the Dirichlet spectral problem associated with an elliptic operator with axial periodic heterogeneities. We extend to the 3D-1D case previous 3D-2D results (see [10]) and we analyze the special case where the scale of thickness is much smaller than the scale of the heterogeneities and the planar coefficient has a unique global minimum in the periodic cell. These results are of great relevance in the comprehension of the wave propagation in nanowires showing axial heterogeneities (see [17]).

  20. Periodicity effects of axial waves in elastic compound rods

    DEFF Research Database (Denmark)

    Nielsen, R. B.; Sorokin, S. V.

    2015-01-01

    Floquet analysis is applied to the Bernoulli-Euler model for axial waves in a periodic rod. Explicit asymptotic formulae for the stop band borders are given and the topology of the stop band pattern is explained. Eigenfrequencies of the symmetric unit cell are determined by the Phase-closure Prin......Floquet analysis is applied to the Bernoulli-Euler model for axial waves in a periodic rod. Explicit asymptotic formulae for the stop band borders are given and the topology of the stop band pattern is explained. Eigenfrequencies of the symmetric unit cell are determined by the Phase...

  1. Scattering of axially channeled particles by atomic strings in crystals

    Energy Technology Data Exchange (ETDEWEB)

    Cherdyntsev, V.V.; Pokhil, G.P.; Ryabov, V.A. (Moskovskij Gosudarstvennyj Univ. (USSR). Nauchno-Issledovatel' skij Inst. Yadernoj Fiziki)

    1983-06-01

    The motion of axially channeled particles at shallow depths is analytically treated. It is shown that there may exist finite trajectories for particles with energies of the order of the critical energy. The effect of focusing upon backscattering yield oscillations is examined. For the transition from axial channeling to planar one, the self-consistent solution of the equations of motion is obtained, which allows to take an exact account of the discrete arrangement of atomic rows making up a planar channel. An analysis of this solution offers a new interpretation of the processes occuring at such transitions.

  2. Buckling localization in a cylindrical panel under axial compression

    DEFF Research Database (Denmark)

    Tvergaard, Viggo; Needleman, A.

    2000-01-01

    Localization of an initially periodic buckling pattern is investigated for an axially compressed elastic-plastic cylindrical panel of the type occurring between axial stiffeners on cylindrical shells. The phenomenon of buckling localization and its analogy with plastic flow localization in tensile...... test specimens is discussed in general. For the cylindrical panel, it is shown that buckling localization develops shortly after a maximum load has been attained, and this occurs for a purely elastic panel as well as for elastic-plastic panels. In a case where localization occurs after a load maximum...

  3. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Head Magnetic resonance imaging (MRI) of the head uses a powerful magnetic field, radio waves and a computer to produce ...

  4. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... content. Related Articles and Media MR Angiography (MRA) Magnetic Resonance, Functional (fMRI) - Brain Head and Neck Cancer Treatment Brain Tumor Treatment Magnetic Resonance Imaging (MRI) Safety Alzheimer's Disease Head Injury Brain ...

  5. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... Articles and Media MR Angiography (MRA) Magnetic Resonance, Functional (fMRI) - Brain Head and Neck Cancer Treatment Brain Tumor Treatment Magnetic Resonance Imaging (MRI) Safety Alzheimer's Disease Head Injury Brain Tumors Images related to ...

  6. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... are the limitations of MRI of the Head? What is MRI of the Head? Magnetic resonance imaging ( ... brain) in routine clinical practice. top of page What are some common uses of the procedure? MR ...

  7. Childhood Head and Neck Irradiation

    Science.gov (United States)

    ... Thyroid Association ® www.thyroid.org Childhood Head & Neck Irradiation What is the thyroid gland? The thyroid gland ... Thyroid Association ® www.thyroid.org Childhood Head & Neck Irradiation Thyroid nodules (see Thyroid Nodule brochure) • Thyroid nodules ...

  8. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... for Brain Tumors Radiation Therapy for Head and Neck Cancer Others : American Stroke Association National Stroke Association ... MRA) Magnetic Resonance, Functional (fMRI) - Brain Head and Neck Cancer Treatment Brain Tumor Treatment Magnetic Resonance Imaging ( ...

  9. Development of steel head joints with fiberglass sucker rod on the base of contact stresses investigation

    Energy Technology Data Exchange (ETDEWEB)

    Kopey, B.V.; Kopey, L.B. [Ivano-Frankivsk State Technical Oil and Gas University (Ukraine); Maksymuk, A.V.; Shcherbyna, N.M. [National Ukrainian Academy of Sciences (Ukraine)

    1998-12-31

    The methods of calculation of contact stresses during cylinder shell tube - steel bandage interaction are presented. Tymoshenko`s generalized theory of shells serves as a basis for investigating steel head to fiberglass sucker rod joint strength. This theory allows to consider mechanical performance of composite materials. The problem is reduced to solving Fredholm integral equation of second degree. The numeric analysis is performed. Several joints of composite body with steel head are proposed. The full-size sucker rod fatigue tests are performed to determine the fatigue limit under the bending and axial cyclic loads in the medium of oil well fluids. (orig.)

  10. Where are we heading

    Energy Technology Data Exchange (ETDEWEB)

    Noto, L.A. [Mobil Corporation, (United States)

    1996-12-31

    The present paper deals with different aspects connected to the global petroleum industry by discussing the way of heading. The aspects cover themes like new frontiers, new relationships, sanctions, global climate change, new alliances and new technology. New frontiers and relationships concern domestic policy affecting the industry, and sanctions are discussed in connection with trade. The author discusses the industry`s participation in the global environmental policy and new alliances to provide greater opportunity for developing new technology

  11. Radial Head Fractures

    OpenAIRE

    Jordan, Robert W.; Jones, Alistair DR.

    2017-01-01

    Background: Radial head fractures are common elbow injuries in adults and are frequently associated with additional soft tissue and bone injuries. Methods: A literature search was performed and the authors’ personal experiences are reported. Results: Mason type I fractures are treated non-operatively with splinting and early mobilisation. The management of Mason type II injuries is less clear with evidence supporting both non-operative treatment and internal fixation. The degree of intra-arti...

  12. Changing head model extent affects finite element predictions of transcranial direct current stimulation distributions

    Science.gov (United States)

    Indahlastari, Aprinda; Chauhan, Munish; Schwartz, Benjamin; Sadleir, Rosalind J.

    2016-12-01

    Objective. In this study, we determined efficient head model sizes relative to predicted current densities in transcranial direct current stimulation (tDCS). Approach. Efficiency measures were defined based on a finite element (FE) simulations performed using nine human head models derived from a single MRI data set, having extents varying from 60%-100% of the original axial range. Eleven tissue types, including anisotropic white matter, and three electrode montages (T7-T8, F3-right supraorbital, Cz-Oz) were used in the models. Main results. Reducing head volume extent from 100% to 60%, that is, varying the model’s axial range from between the apex and C3 vertebra to one encompassing only apex to the superior cerebellum, was found to decrease the total modeling time by up to half. Differences between current density predictions in each model were quantified by using a relative difference measure (RDM). Our simulation results showed that {RDM} was the least affected (a maximum of 10% error) for head volumes modeled from the apex to the base of the skull (60%-75% volume). Significance. This finding suggested that the bone could act as a bioelectricity boundary and thus performing FE simulations of tDCS on the human head with models extending beyond the inferior skull may not be necessary in most cases to obtain reasonable precision in current density results.

  13. Lateral Load Testing of the Advanced Stirling Convertor (ASC-E2) Heater Head

    Science.gov (United States)

    Cornell, Peggy A.; Krause, David L.; Davis, Glen; Robbie, Malcolm G.; Gubics, David A.

    2011-01-01

    Free-piston Stirling convertors are fundamental to the development of NASA s next generation of radioisotope power system, the Advanced Stirling Radioisotope Generator (ASRG). The ASRG will use General Purpose Heat Source (GPHS) modules as the energy source and Advanced Stirling Convertors (ASCs) to convert heat into electrical energy, and is being developed by Lockheed Martin under contract to the Department of Energy. Achieving flight status mandates that the ASCs satisfy design as well as flight requirements to ensure reliable operation during launch. To meet these launch requirements, GRC performed a series of quasi-static mechanical tests simulating the pressure, thermal, and external loading conditions that will be experienced by an ASC-E2 heater head assembly. These mechanical tests were collectively referred to as "lateral load tests" since a primary external load lateral to the heater head longitudinal axis was applied in combination with the other loading conditions. The heater head was subjected to the operational pressure, axial mounting force, thermal conditions, and axial and lateral launch vehicle acceleration loadings. To permit reliable prediction of the heater head s structural performance, GRC completed Finite Element Analysis (FEA) computer modeling for the stress, strain, and deformation that will result during launch. The heater head lateral load test directly supported evaluation of the analysis and validation of the design to meet launch requirements. This paper provides an overview of each element within the test and presents assessment of the modeling as well as experimental results of this task.

  14. A technique for the in situ phase calibration of in-duct axial microphone arrays

    Science.gov (United States)

    Lowis, C. R.; Joseph, P. F.; Sijtsma, P.

    2010-10-01

    In aeroengine noise experiments in-duct microphone arrays are often used to make detailed measurements of the sound field transmitted along the duct. The individual microphones in the array must be calibrated with respect to magnitude, and often more critically with respect to phase. Calibration is difficult to perform in situ due to the presence of the duct. This paper presents a technique to allow in situ phase calibration of axial microphone arrays. It relies on the observation that the measured cross-spectral pressure matrix at the array has a Hermitian Töplitz form in the case where the propagating duct modes are mutually incoherent. Using this property a system of equations can be written which, when solved, allows the phase calibration factors to be obtained. The technique is verified experimentally using a no-flow laboratory rig by comparing the phase calibration factors obtained with those measured in free-field conditions. The accuracy of the phase calibration factors obtained by the technique is limited by the degree of deviation of the measured cross-spectral matrix from Töplitz behaviour. In the experimental results shown this is less than 15° at duct frequencies below ka=25. The technique is a robust and rapid method for calibrating in-duct axial microphone arrays.

  15. Numerical simulation of breakup and detachment of an axially ...

    Indian Academy of Sciences (India)

    The extensional, breakup and detachment dynamics of an axially stretching Newtonian liquid bridge are investigated numerically with a dynamic domain multiphase incompressible flow solver. The multiphase flow solver employs a Cahn–Hilliard phase field model to describe the evolution of the diffuse interfaceseparating ...

  16. Axial drive to nonlinear flow between rotating cylinders

    Science.gov (United States)

    Ashrafi, Nariman; Hazbavi, Abbas

    2014-02-01

    Stability of pseudoplastic rotational flow between cylinders in presence of an independent axial component is investigated. The fluid is assumed to follow the Carreau model and mixed boundary conditions are imposed. The conservation of mass and momentum equations give rise to a four-dimensional low-order dynamical system, including additional nonlinear terms in the velocity components originated from the shear-dependent viscosity. In absence of the axial flow, as the pseudoplasticity effects increases, the purely-azimuthal base flow loses its stability to the vortex structure at a lower critical Taylor number. Emergence of the vortices corresponds to the onset of a supercritical bifurcation also present in the flow of a linear fluid. However, unlike the Newtonian case, pseudoplastic Taylor vortices lose their stability as the Taylor number reaches a second critical number corresponding to the onset of a Hopf bifurcation. Existence of an axial flow induced by a pressure gradient appears to further advance each critical point on the bifurcation diagram. In continuation, complete flow field together with viscosity maps is analyzed for different flow scenarios. Through evaluation of the Lyapunov exponent, flow stability and temporal behavior of the system for cases with and without axial flow are brought to attention.

  17. sizing of wind powered axial flux permanent magnet alternator using

    African Journals Online (AJOL)

    user

    2016-10-04

    Oct 4, 2016 ... In this work, a wind-powered, single-phase, permanent magnet alternator utilizing an axial flux distribution system is developed. Using analytical calculations, the design parameters of the alternator's main dimensions were obtained in a similar procedure for conventional electrical machines. To prove the ...

  18. A cylindrical drift chamber with azimuthal and axial position readout

    Energy Technology Data Exchange (ETDEWEB)

    Bar-Yam, Z.; Cummings, J.P.; Dowd, J.P.; Eugenio, P.; Hayek, M.; Kern, W.; King, E.; Shenhav, N.; Chung, S.U.; Hackenburg, R.W.; Olchanski, C.; Weygand, D.P.; Willutzki, H.J.; Brabson, B.B.; Crittenden, R.R.; Dzierba, A.R.; Gunter, J.; Lindenbusch, R.; Rust, D.R.; Scott, E.; Smith, P.T.; Sulanke, T.; Teige, S.; Denisov, S.; Dushkin, A.; Kochetkov, V.; Lipaev, V.; Popov, A.; Shein, I.; Soldatov, A.; Anoshina, E.V.; Bodyagin, V.A.; Demianov, A.I.; Gribushin, A.M.; Kodolova, O.L.; Korotkikh, V.L.; Kostin, M.A.; Ostrovidov, A.I.; Sarycheva, L.I.; Sinev, N.B.; Vardanyan, I.N.; Yershov, A.A.; Adams, T.; Bishop, J.M.; Cason, N.M.; Sanjari, A.H.; LoSecco, J.M.; Manak, J.J.; Shephard, W.D.; Stienike, D.L.; Taegar, S.A.; Thompson, D.R.; Brown, D.S.; Pedlar, T.; Seth, K.K.; Wise, J.; Zhao, D.; Adams, G.S.; Napolitano, J.; Nozar, M.; Smith, J.A.; Witkowski, M. [Massachusetts Univ., North Dartmouth, MA (United States)]|[Brookhaven National Laboratory, Upton, L.I., NY 11973 (United States)]|[Indiana University, Bloomington, IN 47405 (United States)]|[Institute for High Energy Physics, Protvino (Russian Federation)]|[Institute of Nuclear Physics, Moscow State University, Moscow (Russian Federation)]|[University of Notre Dame, Notre Dame, IN 46556 (United States)]|[Northwestern University, Evanston, IL 60208 (United States)]|[Rensselaer Polytechnic Institute, Troy, NY 12180 (United States)

    1997-02-21

    A cylindrical multiwire drift chamber with axial charge-division has been constructed and used in experiment E852 at Brookhaven National Laboratory. It serves as a trigger element and as a tracking device for recoil protons in {pi}{sup -}p interactions. We describe the chamber`s design considerations, details of its construction, electronics, and performance characteristics. (orig.).

  19. Developmental ossification sequences of the appendicular and axial ...

    African Journals Online (AJOL)

    A pre-hatch developmental study on ossification sequences of axial and appendicular skeletal system in Kuttanad duck embryos was undertaken using 78 viable embryos. From day 3 to day 7 of incubation no ossification densities were seen both by alizarin red staining and computerized radiography. The first indication of ...

  20. Axially Symmetric Bianchi Type-I Bulk-Viscous Cosmological ...

    Indian Academy of Sciences (India)

    Abstract. The present study deals with spatially homogeneous and anisotropic axially symmetric Bianchi type-I cosmological model with time variable cosmological term in the presence of bulk viscous fluid. The Einstein's field equations are solved explicitly by time varying decel- eration parameter q. Consequences of the ...

  1. Integrating public transort networks in the axial model

    NARCIS (Netherlands)

    Gil, J.

    2012-01-01

    This study presents a first step in the development of a model that integrates public transport networks with the space syntax axial model, towards a network model that can describe the multi?modal movement structure of a city and study its patterns and flows. It describes the method for building an

  2. Effect of axial modes on Doppler experiments with gas lasers

    NARCIS (Netherlands)

    Bolwijn, P.T.; Peek, Th.H.; Alkemade, C.T.J.

    1966-01-01

    Power output modulation was obtained by using a moving mirror reflecting one beam back into the laser interferometer. The strong dependence of modulation amplitude on the distance between moving mirror and laser is related to the number, n, of excited axial modes for n > 1.

  3. Axial chromatic aberration of the human eye: frequency or wavelength?

    Science.gov (United States)

    Pease, P L; Barbeito, R

    1989-04-01

    The axial chromatic aberration of the human eye is nearly perfectly described by a linear function when expressed in terms of frequency rather than wavelength. Since linear functions are simple to work with and more readily understood, there are advantages for the expression of these data in terms of frequency.

  4. Landforms along transverse faults parallel to axial zone of folded ...

    Indian Academy of Sciences (India)

    Home; Journals; Journal of Earth System Science; Volume 126; Issue 1. Landforms along transverse faults parallel to axial zone of folded mountain front, north-eastern Kumaun Sub-Himalaya, India. Khayingshing ... Keywords. Himalayan Frontal Thrust; outer Kumaun Himalaya; transverse structure; folded mountain front.

  5. sizing of wind powered axial flux permanent magnet alternator using

    African Journals Online (AJOL)

    user

    2016-10-04

    Oct 4, 2016 ... Using analytical calculations, the design parameters of the alternator's main dimensions were obtained in a ... SIZING OF WIND POWERED AXIAL FLUX PERMANENT MAGNET ALTERNATOR USING ANALYTICAL APPROACH,. A. O. Otuoze, et al .... then be expressed as. Equation (7) can be re-written as.

  6. Atlanto-axial instability in rheumatoid arthritis: a review | Omar ...

    African Journals Online (AJOL)

    High index of suspicion and early intervention results in good outcomes and prevents neurological outcome. Conclusion: Cervical spine involvement in rheumatoid arthritis is common and debilitating. Atlanto-axial instability is the commonest form. Early diagnosis and treatment is key in management. Early selective choice ...

  7. Fatigue Limit of Axially Compressed Concrete | Levchich | Nigerian ...

    African Journals Online (AJOL)

    An attempt to evaluate analytically the fatigue limit of axially loaded concrete depending upon the load parameters, number of load cycles and static short-term strength is presented. The conventional limit of concrete microcracking statical sustained strength of concrete, curvelinear relationship between fatigue limit and load ...

  8. Ocular Axial Length and Keratometry Readings of Normal Eyes in ...

    African Journals Online (AJOL)

    Aim: To provide average axial length and keratometry readings in healthy eyes of people in Rivers and surrounding states in southern Nigeria. This may guide the purchase of intraocular lens in the study area. Materials and methods: Four hundred consecutive patients with 800 non-cataractous eyes attending the eye clinic ...

  9. first principles derivation of a stress function for axially symmetric

    African Journals Online (AJOL)

    HOD

    In this work, a stress function is derived from first principles to describe the behaviour of three dimensional axially symmetric elasticity problems involving linear elastic, isotropic homogeneous materials. In the process, the fifteen governing partial differential equations of linear isotropic elasticity were reduced to the solution ...

  10. Axial phenoxide coordination on di-iron(III) bisporphyrin: Insights ...

    Indian Academy of Sciences (India)

    Abstract. Synthesis, structure and properties of new five-coordinate phenolate complexes of di-iron(III) bis- porphyrin are reported here, in which phenol binds in η1-fashion as an axial ligand. The solid and solu- tion EPR at 120 K and 1H NMR spectral pattern in solution provide unequivocal evidence for the high spin.

  11. On the generation techniques of axially symmetric stationary metrics

    Indian Academy of Sciences (India)

    General relativity; Einstein's equations; relation between solution generating techniques; soliton technique; method of Gutsunaev–Manko. ... and the soliton technique (for two-soliton solutions) of Belinskii–Zakharov, for generating solutions of axially symmetric stationary space-times in general relativity is discussed.

  12. 3-D Simulation of Vertical-Axial Tidal Current Turbine

    Directory of Open Access Journals (Sweden)

    Zhiyang Zhang

    2016-12-01

    Full Text Available Vertical-axial tidal current turbine is the key for the energy converter, which has the advantages of simple structure, adaptability to flow and uncomplex convection device. It has become the hot point for research and application recently. At present, the study on the hydrodynamic performance of vertical-axial tidal current turbine is almost on 2-D numerical simulation, without the consideration of 3-D effect. CFD (Computational Fluid Dynamics method and blade optimal control technique are used to improve accuracy in the prediction of tidal current turbine hydrodynamic performance. Numerical simulation of vertical-axial tidal current turbine is validated. Fixed and variable deflection angle turbine are comparatively studied to analysis the influence of 3-D effect and the character of fluid field and pressure field. The method, put the plate on the end of blade, of reduce the energy loss caused by 3-D effect is proposed. The 3-D CFD numerical model of vertical-axial tidal current turbine hydrodynamic performance in this study may provide theoretical, methodical and technical reference for the optimal design of turbine.

  13. Perturbation approximation for orbits in axially symmetric funnels

    Science.gov (United States)

    Nauenberg, Michael

    2014-11-01

    A perturbation method that can be traced back to Isaac Newton is applied to obtain approximate analytic solutions for objects sliding in axially symmetric funnels in near circular orbits. Some experimental observations are presented for balls rolling in inverted cones with different opening angles, and in a funnel with a hyperbolic surface that approximately simulates the gravitational force.

  14. Etanercept for the treatment of non-radiographic axial spondyloarthritis.

    Science.gov (United States)

    Rios Rodriguez, Valeria; Poddubnyy, Denis

    2016-01-01

    Presently, tumor necrosis factor α antagonist therapy is the only effective alternative treatment to nonsteroidal anti-inflammatory drugs for the entire spectrum of axial spondyloarthritis, including non-radiographic and radiographic (=ankylosing spondylitis) forms. Recently, etanercept has been approved by the European Medicines Agency for the treatment of non-radiographic axial spondyloarthritis, increasing the number of available treatment options for this indication. The latest data on etanercept concerning clinical efficacy and safety in short-term and long-term treatment of patients with non-radiographic axial spondyloarthritis who do not respond to the first-line therapy with non-steroidal anti-inflammatory drugs suggests good efficacy and safety profiles similar to that observed previously in ankylosing spondylitis. This article reviews recent data on the efficacy and safety of etanercept and is focused on the treatment of non-radiographic axial spondyloarthritis. This article will also discuss the role of etanercept in the context of current and developing treatment options.

  15. On the generation techniques of axially symmetric stationary metrics

    Indian Academy of Sciences (India)

    On the generation techniques of axially symmetric stationary metrics. S CHAUDHURI. Department of Physics, Gushkara Mahavidyalaya, Gushkara, Burdwan 713 128, India. Address for correspondence: Chaudhuri Lane, R.K. Palli, Badamtala, Burdwan 713 101, India. MS received 18 October 2000; revised 1 June 2001.

  16. Evaluation of electromagnetic shielding effectiveness of multi-axial ...

    Indian Academy of Sciences (India)

    Also, the EMSE performance of multi-axial fabrics was found better than their reinforced composites. The best EMSE results were obtained for the ... Author Affiliations. RAMAZAN ERDEM1. Department of Textile Technology, Serik G.S. Süral Vocational School of Higher Education, Akdeniz University, 07500 Antalya, Turkey ...

  17. Axial Length/Corneal Radius of Curvature Ratio and Refractive ...

    African Journals Online (AJOL)

    2017-12-05

    Dec 5, 2017 ... Aim/Background: Associations between axial length (AL) to corneal radius of curvature (CR) ratio and refractive status in a healthy Nigerian adult population were studied. Materials and Methods: Healthy students and members of staff of Obafemi Awolowo Teaching Hospitals Complex, Ile-Ife, South West ...

  18. NORMAL AXIAL ANGLES OF THE KNEE JOINT IN ADULT ...

    African Journals Online (AJOL)

    hi-tech

    2003-08-01

    Aug 1, 2003 ... recommend the establishment of normal ranges of axial angles as a prerequisite for proper orthopaedic clinical practice in this part of the world. REFERENCES. 1. Nigel P., Derek F. and Roger S. The hip joint . In: Anatomy and human movement - structure and function. Ed. 3, Oxford Butterwoth - Heinemann ...

  19. On aspects of vibration of axially moving continua

    NARCIS (Netherlands)

    Hageraats-Ponomareva, S.

    2009-01-01

    In axially moving structures like conveyor belt systems, magnetic tapes, and so on, vibrations occur due to the presence of different kinds of imperfections in the systems. For these structures internal resonances can lead to severe vibrations. Resonance free conveyor belt systems can be constructed

  20. Axial Torsion of Gangrenous Meckel's Diverticulum Causing Small ...

    African Journals Online (AJOL)

    Meckel's diverticulum (MD) is a commonly encountered congenital anomaly of the small intestine. We report an extremely unusual case of an axially torted, gangrenous MD presenting as acute intestinal obstruction. A 26-year-old male patient presented to our emergency department with 3 days history of abdominal pain, ...

  1. Report on the Dynamical Evolution of an Axially Symmetric Quasar ...

    Indian Academy of Sciences (India)

    The role of the angular momentum in the regular or chaotic character of motion in an axially symmetric quasar model is examined. It is found that, for a given value of the critical angular momentum , there are two values of the mass of the nucleus for which transition from regular to chaotic motion occurs.

  2. Axial Length/Corneal Radius of Curvature Ratio and Refractive ...

    African Journals Online (AJOL)

    Aim/Background: Associations between axial length (AL) to corneal radius of curvature (CR) ratio and refractive status in a healthy Nigerian adult population were studied. Materials and Methods: Healthy students and members of staff of Obafemi Awolowo Teaching Hospitals Complex, Ile‑Ife, South West Nigeria, free of ...

  3. Axial Length/Corneal Radius of Curvature Ratio and Refractive ...

    African Journals Online (AJOL)

    2018-02-07

    Feb 7, 2018 ... Aim/Background: Associations between axial length (AL) to corneal radius of curvature (CR) ratio and refractive status in a healthy Nigerian adult population were studied. Materials and Methods: Healthy students and members of staff of Obafemi Awolowo Teaching Hospitals Complex, Ile-Ife, South West ...

  4. Kinetics and equilibria for the axial ligation of bromomethyl (aqua ...

    Indian Academy of Sciences (India)

    Home; Journals; Journal of Chemical Sciences; Volume 121; Issue 6. Kinetics and equilibria for the axial ligation of bromomethyl (aqua)cobaloxime with pyridines - Isolation characterization and DNA binding. Kotha Laxma Reddy K Ashwini Kumar N Ravi Kumar Reddy Penumaka Nagababu A Panasa Reddy S ...

  5. Static Tension Tests on Axially Loaded Pile Segments in Sand

    DEFF Research Database (Denmark)

    Thomassen, Kristina; Andersen, Lars Vabbersgaard; Ibsen, Lars Bo

    This paper provides laboratory test results of static axially loaded piles in sand. With a newly developed test setup, the pile-soil interface friction was investigated by using an open-ended steel pile segment with a diameter of 0.5 m. Use of a pile length of 1 m enabled the pile-soil interface...

  6. Comparison of design methods for axially loaded buckets in sand

    DEFF Research Database (Denmark)

    Vaitkunaite, Evelina; Nielsen, Benjaminn Nordahl; Ibsen, Lars Bo

    2015-01-01

    A study of the present knowledge about the bucket resistance for axial loading was performed considering analytical and numerical design methods as well as physical models. A case study was performed with two bucket foundations of equal diameter, but different skirt lengths installed in dense san...

  7. Aryabha~a and Axial Rotation of Earth

    Indian Academy of Sciences (India)

    GENERAL I ARTICLE. Aryabha~a and Axial Rotation of Earth. 2. Naksatra ... there are plenty of articles on Aryabhata, their contents have remained confined to research journals and ...... system often called the "Bh- iitasankhya" (whose roots too can be traced to Vedic literature) or adopted a Classical alphabetical decimal ...

  8. [Investigations on the prevalence of axial and refractive anisometropia].

    Science.gov (United States)

    Majdanik, Ewa; Czepita, Damian; Safranow, Krzysztof

    2012-01-01

    The aim of this paper was to describe the prevalence of axial and refractive anisometropia among students 18 years old. The study was carried out among high school students 18 years old in Szczecin, Poland. A total of 1040 students including 381 boys and 659 girls were examined. Every student underwent retinoscopy after cycloplegia using 1% Tropicamide. The differences in spherical equivalents in the right and left eye, were calculated. Students who had anisometropia >1.00 Dsph, were qualified to the next part of the studies, in which examinations using an autorefractometer, keratometer, biometric ultrasounds as well as the IOL Master were carried out. In the group of 70 students (which makes up 7% of the examined population), qualified to the next part of the examinations, a total of 20 participants (2%) declined. The remaining 50 students (5%) were divided into two groups. One group consisted of students with axial anisometropia, while the other consisted of students with refractive anisometropia. All of the collected data were stored in an electronic database using the Microsoft EXCEL computer program and analyzed with Statistica 6.1 software. In the analysis of nominal variables the Fisher exact test was used. P values of less than 0.05 were considered statistically significant. In the conducted studies a higher prevalence of axial anisometropia (60%) compared to refractive anisometropia (40%) was observed, but the difference did not reach statistical significance (p = 0.20). No association between the type of anisometropia and gender was found in the studies. Axial anisometropia was found in 60% of boys and girls in the study group qualified to the second part of the examinations, while refractive anisometropia was found in 40% of boys and girls qualified to the next part of the examinations. Anisometropia in students 18 years old is caused more often by different axial length rather than by different refraction of the eye.

  9. High-resolution axial MR imaging of tibial stress injuries

    Science.gov (United States)

    2012-01-01

    Purpose To evaluate the relative involvement of tibial stress injuries using high-resolution axial MR imaging and the correlation with MR and radiographic images. Methods A total of 33 patients with exercise-induced tibial pain were evaluated. All patients underwent radiograph and high-resolution axial MR imaging. Radiographs were taken at initial presentation and 4 weeks later. High-resolution MR axial images were obtained using a microscopy surface coil with 60 × 60 mm field of view on a 1.5T MR unit. All images were evaluated for abnormal signals of the periosteum, cortex and bone marrow. Results Nineteen patients showed no periosteal reaction at initial and follow-up radiographs. MR imaging showed abnormal signals in the periosteal tissue and partially abnormal signals in the bone marrow. In 7 patients, periosteal reaction was not seen at initial radiograph, but was detected at follow-up radiograph. MR imaging showed abnormal signals in the periosteal tissue and entire bone marrow. Abnormal signals in the cortex were found in 6 patients. The remaining 7 showed periosteal reactions at initial radiograph. MR imaging showed abnormal signals in the periosteal tissue in 6 patients. Abnormal signals were seen in the partial and entire bone marrow in 4 and 3 patients, respectively. Conclusions Bone marrow abnormalities in high-resolution axial MR imaging were related to periosteal reactions at follow-up radiograph. Bone marrow abnormalities might predict later periosteal reactions, suggesting shin splints or stress fractures. High-resolution axial MR imaging is useful in early discrimination of tibial stress injuries. PMID:22574840

  10. The Nucleon Axial Form Factor and Staggered Lattice QCD

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, Aaron Scott [Chicago U.

    2017-01-01

    The study of neutrino oscillation physics is a major research goal of the worldwide particle physics program over the upcoming decade. Many new experiments are being built to study the properties of neutrinos and to answer questions about the phenomenon of neutrino oscillation. These experiments need precise theoretical cross sections in order to access fundamental neutrino properties. Neutrino oscillation experiments often use large atomic nuclei as scattering targets, which are challenging for theorists to model. Nuclear models rely on free-nucleon amplitudes as inputs. These amplitudes are constrained by scattering experiments with large nuclear targets that rely on the very same nuclear models. The work in this dissertation is the rst step of a new initiative to isolate and compute elementary amplitudes with theoretical calculations to support the neutrino oscillation experimental program. Here, the eort focuses on computing the axial form factor, which is the largest contributor of systematic error in the primary signal measurement process for neutrino oscillation studies, quasielastic scattering. Two approaches are taken. First, neutrino scattering data on a deuterium target are reanalyzed with a model-independent parametrization of the axial form factor to quantify the present uncertainty in the free-nucleon amplitudes. The uncertainties on the free-nucleon cross section are found to be underestimated by about an order of magnitude compared to the ubiquitous dipole model parametrization. The second approach uses lattice QCD to perform a rst-principles computation of the nucleon axial form factor. The Highly Improved Staggered Quark (HISQ) action is employed for both valence and sea quarks. The results presented in this dissertation are computed at physical pion mass for one lattice spacing. This work presents a computation of the axial form factor at zero momentum transfer, and forms the basis for a computation of the axial form factor momentum dependence

  11. Axial differentiation and early gastrulation stages of the pig embryo.

    Science.gov (United States)

    Hassoun, Romia; Schwartz, Peter; Feistel, Kerstin; Blum, Martin; Viebahn, Christoph

    2009-12-01

    Differentiation of the principal body axes in the early vertebrate embryo is based on a specific blueprint of gene expression and a series of transient axial structures such as Hensen's node and the notochord of the late gastrulation phase. Prior to gastrulation, the anterior visceral endoderm (AVE) of the mouse egg-cylinder or the anterior marginal crescent (AMC) of the rabbit embryonic disc marks the anterior pole of the embryo. For phylogenetic and functional reasons both these entities are addressed here as the mammalian anterior pregastrulation differentiation (APD). However, mouse and rabbit show distinct structural differences in APD and the molecular blueprint, making the search of general rules for axial differentiation in mammals difficult. Therefore, the pig was analysed here as a further species with a mammotypical flat embryonic disc. Using light and electron microscopy and in situ hybridisation for three key genes involved in early development (sox17, nodal and brachyury), two axial structures of early gastrulation in the pig were identified: (1) the anterior hypoblast (AHB) characterised by increased cellular height and density and by sox17 expression, and (2) the early primitive streak characterised by a high pseudostratified epithelium with an almost continuous but unusually thick basement membrane, by localised epithelial-mesenchymal transition, and by brachyury expression in the epiblast. The stepwise appearance of these two axial structures was used to define three stages typical for mammals at the start of gastrulation. Intriguingly, the round shape and gradual posterior displacement of the APD in the pig appear to be species-specific (differing from all other mammals studied in detail to date) but correlate with ensuing specific primitive streak and extraembryonic mesoderm development. APD and, hence, the earliest axial structure presently known in the mammalian embryo may thus be functionally involved in shaping extraembryonic membranes and

  12. Head circumference in Iranian infants

    Directory of Open Access Journals (Sweden)

    Mohammad Esmaeili

    2015-03-01

    Full Text Available Introduction: Head circumference (HC measurement is one of the important parameter for diagnosis of neurological, developmental disorders and dysmorphic syndromes. Recognition of different disorders requires an understanding of normal variation for HC size, in particular, in infancy period with most rapid growth of the brain. Because of international and interracial standard chart differences about anthropometric indices, some differences from local to local, generation to generation and changes in ethnic mix of population and socioeconomic factors, periodic revolution of HC size is suggested. The aims of our study were presenting local HC standard for an Iranian infant population and comparison with the American national center of health statistics (NCHS charts accepted by WHO. Methods: 1003 subjects aged from birth to 24 months apparently healthy normal children enrolled randomly in this cross sectional study. HC size were measured and recorded. Tables and graphs were depicted by Excel Microsoft Office 2007. We use two tailed t-student test for statistical analysis. Results: The mean of HC size in boys was larger than girls. The curves were followed a similar pattern to NCHS based on a visual comparison. Overall our subjects in both sexes at birth time had smaller HC size than NCHS. In other ages our children had larger HC size than those of NCHS. Conclusion: Because of international and interracial difference of HC size. We recommend in each area of the world, local anthropometric indices are constructed and used clinically. In addition more extensive and longitudinally design comprehensive studies is suggested.

  13. Hydraulic design and analysis of the saxo-type vertical axial turbine

    Energy Technology Data Exchange (ETDEWEB)

    Hofler, Edvard; Gale, Janez; Bergant, Anton

    2010-07-01

    The design of the blade geometry of a wind turbine is highly important as it influences the power generation. The aim of this study is to introduce a method for hydraulic design and analysis of the blade geometry of a highly specific speed runner of the Saxo-type double-regulated vertical axial turbine. The streamline curvature method (SCM) was used to develop four blade shapes which were analyzed with computational fluid dynamics (CFD) tools and the best one chosen in term of turbine efficiency and cavitational characteristics. Results demonstrated that the physical shape of the blade can be found for the design duty point in a rapid and transparent way by using the SCM method with no adjustments required to use the CFD methods. This study proved that the SCM design procedure developed herein can be used to accurately design runner blades.

  14. Non-steroidal anti-inflammatory drugs (NSAIDs) for axial spondyloarthritis (ankylosing spondylitis and non-radiographic axial spondyloarthritis)

    NARCIS (Netherlands)

    Kroon, Feline P. B.; van der Burg, Lennart R. A.; Ramiro, Sofia; Landewé, Robert B. M.; Buchbinder, Rachelle; Falzon, Louise; van der Heijde, Désirée

    2015-01-01

    Axial spondyloarthritis (axSpA) comprises ankylosing spondylitis (radiographic axSpA) and non-radiographic (nr-)axSpA and is associated with psoriasis, uveitis and inflammatory bowel disease. Non-steroidal anti-inflammatory drugs (NSAIDs) are recommended as first-line drug treatment. To determine

  15. Bumblebee Homing: The Fine Structure of Head Turning Movements.

    Directory of Open Access Journals (Sweden)

    Norbert Boeddeker

    Full Text Available Changes in flight direction in flying insects are largely due to roll, yaw and pitch rotations of their body. Head orientation is stabilized for most of the time by counter rotation. Here, we use high-speed video to analyse head- and body-movements of the bumblebee Bombus terrestris while approaching and departing from a food source located between three landmarks in an indoor flight-arena. The flight paths consist of almost straight flight segments that are interspersed with rapid turns. These short and fast yaw turns ("saccades" are usually accompanied by even faster head yaw turns that change gaze direction. Since a large part of image rotation is thereby reduced to brief instants of time, this behavioural pattern facilitates depth perception from visual motion parallax during the intersaccadic intervals. The detailed analysis of the fine structure of the bees' head turning movements shows that the time course of single head saccades is very stereotypical. We find a consistent relationship between the duration, peak velocity and amplitude of saccadic head movements, which in its main characteristics resembles the so-called "saccadic main sequence" in humans. The fact that bumblebee head saccades are highly stereotyped as in humans, may hint at a common principle, where fast and precise motor control is used to reliably reduce the time during which the retinal images moves.

  16. Head First Web Design

    CERN Document Server

    Watrall, Ethan

    2008-01-01

    Want to know how to make your pages look beautiful, communicate your message effectively, guide visitors through your website with ease, and get everything approved by the accessibility and usability police at the same time? Head First Web Design is your ticket to mastering all of these complex topics, and understanding what's really going on in the world of web design. Whether you're building a personal blog or a corporate website, there's a lot more to web design than div's and CSS selectors, but what do you really need to know? With this book, you'll learn the secrets of designing effecti

  17. Head First Python

    CERN Document Server

    Barry, Paul

    2010-01-01

    Ever wished you could learn Python from a book? Head First Python is a complete learning experience for Python that helps you learn the language through a unique method that goes beyond syntax and how-to manuals, helping you understand how to be a great Python programmer. You'll quickly learn the language's fundamentals, then move onto persistence, exception handling, web development, SQLite, data wrangling, and Google App Engine. You'll also learn how to write mobile apps for Android, all thanks to the power that Python gives you. We think your time is too valuable to waste struggling with

  18. Head first C#

    CERN Document Server

    Stellman, Andrew

    2010-01-01

    You want to learn C# programming, but you're not sure you want to suffer through another tedious technical book. You're in luck: Head First C# introduces this language in a fun, visual way. You'll quickly learn everything from creating your first program to learning sophisticated coding skills with C# 4.0, Visual Studio 2010 and .NET 4, while avoiding common errors that frustrate many students. The second edition offers several hands-on labs along the way to help you build and test programs using skills you've learned up to that point. In the final lab, you'll put everything together. From o

  19. Head first C#

    CERN Document Server

    Stellman, Andrew

    2008-01-01

    Head First C# is a complete learning experience for object-oriented programming, C#, and the Visual Studio IDE. Built for your brain, this book covers C# 3.0 and Visual Studio 2008, and teaches everything from language fundamentals to advanced topics including garbage collection, extension methods, and double-buffered animation. You'll also master C#'s hottest and newest syntax, LINQ, for querying SQL databases, .NET collections, and XML documents. By the time you're through, you'll be a proficient C# programmer, designing and coding large-scale applications. Every few chapters you will come

  20. Head First Mobile Web

    CERN Document Server

    Gardner, Lyza; Grigsby, Jason

    2011-01-01

    Despite the huge number of mobile devices and apps in use today, your business still needs a website. You just need it to be mobile. Head First Mobile Web walks you through the process of making a conventional website work on a variety smartphones and tablets. Put your JavaScript, CSS media query, and HTML5 skills to work-then optimize your site to perform its best in the demanding mobile market. Along the way, you'll discover how to adapt your business strategy to target specific devices. Navigate the increasingly complex mobile landscapeTake both technical and strategic approaches to mobile

  1. Axial disability and deep brain stimulation in patients with Parkinson disease

    NARCIS (Netherlands)

    Fasano, A.; Aquino, C.C.; Krauss, J.K.; Honey, C.R.; Bloem, B.R.

    2015-01-01

    Axial motor signs-including gait impairment, postural instability and postural abnormalities-are common and debilitating symptoms in patients with advanced Parkinson disease. Dopamine replacement therapy and physiotherapy provide, at best, partial relief from axial motor symptoms. In carefully

  2. Axial-Stereo 3-D Optical Metrology for Inner Profile of Pipes Using a Scanning Laser Endoscope.

    Science.gov (United States)

    Gong, Yuanzheng; Johnston, Richard S; Melville, C David; Seibel, Eric J

    As the rapid progress in the development of optoelectronic components and computational power, 3D optical metrology becomes more and more popular in manufacturing and quality control due to its flexibility and high speed. However, most of the optical metrology methods are limited to external surfaces. This paper proposed a new approach to measure tiny internal 3D surfaces with a scanning fiber endoscope and axial-stereo vision algorithm. A dense, accurate point cloud of internally machined threads was generated to compare with its corresponding X-ray 3D data as ground truth, and the quantification was analyzed by Iterative Closest Points algorithm.

  3. Research on the forward modeling of controlled-source audio-frequency magnetotellurics in three-dimensional axial anisotropic media

    Science.gov (United States)

    Wang, Kunpeng; Tan, Handong

    2017-11-01

    Controlled-source audio-frequency magnetotellurics (CSAMT) has developed rapidly in recent years and are widely used in the area of mineral and oil resource exploration as well as other fields. The current theory, numerical simulation, and inversion research are based on the assumption that the underground media have resistivity isotropy. However a large number of rock and mineral physical property tests show the resistivity of underground media is generally anisotropic. With the increasing application of CSAMT, the demand for probe accuracy of practical exploration to complex targets continues to increase. The question of how to evaluate the influence of anisotropic resistivity to CSAMT response is becoming important. To meet the demand for CSAMT response research of resistivity anisotropic media, this paper examines the CSAMT electric equations, derives and realizes a three-dimensional (3D) staggered-grid finite difference numerical simulation method of CSAMT resistivity axial anisotropy. Through building a two-dimensional (2D) resistivity anisotropy geoelectric model, we validate the 3D computation result by comparing it to the result of controlled-source electromagnetic method (CSEM) resistivity anisotropy 2D finite element program. Through simulating a 3D resistivity axial anisotropy geoelectric model, we compare and analyze the responses of equatorial configuration, axial configuration, two oblique sources and tensor source. The research shows that the tensor source is suitable for CSAMT to recognize the anisotropic effect of underground structure.

  4. Laboratory Test Setup for Cyclic Axially Loaded Piles in Sand

    DEFF Research Database (Denmark)

    Thomassen, Kristina; Ibsen, Lars Bo; Andersen, Lars Vabbersgaard

    2017-01-01

    This paper presents a comprehensive description and the considerations regarding the design of a new laboratory test setup for testing cyclic axially loaded piles in sand. The test setup aims at analysing the effect of axial one-way cyclic loading on pile capacity and accumulated displacements....... Another aim was to test a large diameter pile segment with dimensions resembling full-scale piles to model the interface properties between pile and sand correctly. The pile segment was an open-ended steel pipe pile with a diameter of 0.5 m and a length of 1 m. The sand conditions resembled the dense sand...... determined from the API RP 2GEO standard and from the test results indicated over consolidation of the sand. Two initial one-way cyclic loading tests provided results of effects on pile capacity and accumulated displacements in agreement with other researchers’ test results....

  5. Reduced aniseikonia in axial anisometropia with contact lens correction.

    Science.gov (United States)

    Winn, B; Ackerley, R G; Brown, C A; Murray, F K; Prais, J; St John, M F

    1988-01-01

    Aniseikonia, although present in isometropia, is associated principally with anisometropia and is widely thought to be the result of differences in the retinal image size presented to each eye. This assumes that equating retinal image size results in congruous cortical images. To test this assumption 1 refractive and 17 axial anisometropic subjects were examined to determine the aniseikonia present when corrected with spectacles and contact lenses. Contrary to many previous predictions, based upon Knapp's Law, the presence of equal retinal images resulted in larger aniseikonias than observed when the eyes were presented with unequal retinal images. This suggests that non-optical components have a significant role in the production of the cortical image, and this therefore requires a shift in the way the management of anisometropia is considered clinically. Contact lens correction maintains the aniseikonia at a minimum level in axial as well as refractive anisometropia and offers the clinician an acceptable practical alternative when prescribing for these patients.

  6. Finite-Size Scaling of Vector and Axial Current Correlators

    CERN Document Server

    Damgaard, P H; Jansen, K; Laine, Mikko; Lellouch, L P

    2003-01-01

    Using quenched chiral perturbation theory, we compute the long-distance behaviour of two-point functions of flavour non-singlet axial and vector currents in a finite volume, for small quark masses, and at a fixed gauge-field topology. We also present the corresponding predictions for the unquenched theory at fixed topology. These results can in principle be used to measure the low-energy constants of the chiral Lagrangian, from lattice simulations in volumes much smaller than one pion Compton wavelength. We show that quenching has a dramatic effect on the vector correlator, which is argued to vanish to all orders, while the axial correlator appears to be a robust observable only moderately sensitive to quenching.

  7. First Calculation of Hyperon Axial Couplings from Lattice QCD

    Energy Technology Data Exchange (ETDEWEB)

    Huey-Wen Lin; Konstantinos Orginos

    2007-12-06

    In this work, we report the first lattice calculation of the hyperon axial couplings, using the 2+1-flavor MILC configurations and domain-wall fermion valence quarks. Both the $\\Sigma$ and $\\Xi$ axial couplings are for the first time done in lattice QCD, and we find the numbers with greater precision than previous chiral perturbation theory and large-$N_c$ theory estimate: $g_{\\Sigma\\Sigma} = 0.450(21)_{\\rm stat}(22)_{\\rm syst}$ and $g_{\\Xi\\Xi} = -0.277(15)_{\\rm stat}(16)_{\\rm syst}$. As a side product, we also determine the low-energy chiral parameters $D$ and $F$ extracted from these coupling constants: $D=0.715(6)_{\\rm stat}(6)_{\\rm syst}$ and $F=0.453(5)_{\\rm stat}(5)_{\\rm syst}$.

  8. Axial Ge/Si nanowire heterostructure tunnel FETs

    Energy Technology Data Exchange (ETDEWEB)

    Picraux, Sanuel T [Los Alamos National Laboratory; Daych, Shadi A [Los Alamos National Laboratory

    2010-01-01

    The vapor-liquid-solid (VLS) growth of semiconductor nanowires allows doping and composition modulation along their axis and the realization of axial 1 D heterostructures. This provides additional flexibility in energy band-edge engineering along the transport direction which is difficult to attain by planar materials growth and processing techniques. We report here on the design, growth, fabrication, and characterization of asymmetric heterostructure tunnel field-effect transistors (HTFETs) based on 100% compositionally modulated Si/Ge axial NWs for high on-current operation and low ambipolar transport behavior. We discuss the optimization of band-offsets and Schottky barrier heights for high performance HTFETs and issues surrounding their experimental realization. Our HTFET devices with 10 nm PECVD SiN{sub x} gate dielectric resulted in a measured current drive exceeding 100 {mu}A/{mu}m (I/{pi}D) and 10{sup 5} I{sub on}/I{sub off} ratios.

  9. Effect of axial mixing on RDC and PSE columns performance

    CERN Document Server

    Bastani, D

    2001-01-01

    Using the experimental data obtained from two RDC columns at two different sizes (7.62 and 21.9 cm) and one PSE column with 21.5 cm size, the effect of axial mixing on the performance of these columns was studied. Comparison between the experimental and theoretical (neglecting the axial mixing) number of transfer units indicates that, this effect in PSE columns is more than RDC columns (400% and 200% respectively). These results show that this effect can increase the height of the PSE column up to 4 times for a specific efficiency. Also the results show that this effect is more in law interfacial tension systems, which shows no need of application of agitation facilities when these systems are used.

  10. Fast imaging of mean, axial and radial diffusion kurtosis

    DEFF Research Database (Denmark)

    Hansen, Brian; Shemesh, Noam; Jespersen, Sune Nørhøj

    2016-01-01

    Abstract Diffusion kurtosis imaging (DKI) is being increasingly reported to provide sensitive biomarkers of subtle changes in tissue microstructure. However, DKI also imposes larger data requirements than diffusion tensor imaging (DTI), hence, the widespread adaptation and exploration of DKI would...... benefit from more efficient acquisition and computational methods. To meet this demand, we recently developed a method capable of estimating mean kurtosis with only 13 diffusion weighted images. This approach was later shown to provide very accurate mean kurtosis estimates and to be more efficient......'s principal parameters – mean kurtosis, radial kurtosis, and axial kurtosis – using only 19 diffusion weighted images, compared to the current state-of-the-art acquisitions typically requiring about 60 images. The first approach is based on axially symmetric diffusion and kurtosis tensors, presented here...

  11. Long-term durability test of axial-flow ventricular assist device under pulsatile flow.

    Science.gov (United States)

    Nishida, Masahiro; Kosaka, Ryo; Maruyama, Osamu; Yamane, Takashi; Shirasu, Akio; Tatsumi, Eisuke; Taenaka, Yoshiyuki

    2017-03-01

    A long-term durability test was conducted on a newly developed axial-flow ventricular assist device (VAD) with hydrodynamic bearings. The mock circulatory loop consisted of a diaphragm pump with a mechanical heart valve, a reservoir, a compliance tank, a resistance valve, and flow paths made of polymer or titanium. The VAD was installed behind the diaphragm pump. The blood analog fluid was a saline solution with added glycerin at a temperature of 37 °C. A pulsatile flow was introduced into the VAD over a range of flow rates to realize a positive flow rate and a positive pressure head at a given impeller rotational speed, yielding a flow rate of 5 L/min and a pressure of 100 mmHg. Pulsatile flow conditions were achieved with the diastolic and systolic flow rates of ~0 and 9.5 L/min, respectively, and an average flow rate of ~5 L/min at a pulse rate of 72 bpm. The VAD operation was judged by not only the rotational speed of the impeller, but also the diastolic, systolic, and average flow rates and the average pressure head of the VAD. The conditions of the mock circulatory loop, including the pulse rate of the diaphragm pump, the fluid temperature, and the fluid viscosity were maintained. Eight VADs were tested with testing periods of 2 years, during which they were continuously in operation. The VAD performance factors, including the power consumption and the vibration characteristics, were kept almost constant. The long-term durability of the developed VAD was successfully demonstrated.

  12. Study of the axial heat conduction in parallel flow microchannel heat exchanger

    Directory of Open Access Journals (Sweden)

    Mushtaq Ismael Hasan

    2014-07-01

    The results showed that, the axial heat conduction plays an important role in a parallel flow microchannel heat exchanger and the factors affecting the local and average axial heat conduction are; Reynolds number (Re, thermal conductivity ratio (Kr, hydraulic diameter (Dh, thickness of separating wall (ts and channel volume. Increasing of Re, Kr and ts leads to an increase in the axial heat conduction while increasing of Dh and channel volume leads to a decrease in the axial heat conduction.

  13. Numerical analysis of a microwave torch with axial gas injection

    Energy Technology Data Exchange (ETDEWEB)

    Gritsinin, S. I.; Davydov, A. M.; Kossyi, I. A., E-mail: kossyi@fpl.gpi.ru [Russian Academy of Sciences, Prokhorov General Physics Institute (Russian Federation); Kulumbaev, E. B. [National Research University Belgorod State University (Russian Federation); Lelevkin, V. M. [Kyrgyz-Russian Slavic University (Kyrgyzstan)

    2013-07-15

    The characteristics of a microwave discharge in an argon jet injected axially into a coaxial channel with a shortened inner electrode are numerically analyzed using a self-consistent equilibrium gas-dynamic model. The specific features of the excitation and maintenance of the microwave discharge are determined, and the dependences of the discharge characteristics on the supplied electromagnetic power and gas flow rate are obtained. The calculated results are compared with experimental data.

  14. Modelling of a Bi-axial Vibration Energy Harvester

    Science.gov (United States)

    2013-05-01

    effect of the electrical load on the transduction, and on the mechanical dynamics. It was demonstrated that the back EMF from current flow in the...created with a permanent-magnet/ball-bearing arrangement. The mechanical oscillations of the ball-bearing in response to bi-axial vibrations in a host...system on an aircraft platform. Modelling of the mechanical dynamics and the electromechanical transduction of the harvester is undertaken by: means of

  15. Axial Magnetic Field Effect on Taylor-Couette Flow

    OpenAIRE

    Sofiane ABERKANE; IHDENE malika; mouderes mourad; ghezal abderrahmane

    2015-01-01

    This study is interested in the effect of an axial magnetic field imposed on incompressible flow of electrically conductive fluid between two horizontal coaxial cylinders. The imposed magnetic field is assumed uniform and constant. The effect of heat generation due to viscous dissipation is also taken into account. The inner and outer cylinders are maintained at different uniform temperatures. The movement of the fluid is due to rotation of the cylinder with a constant speed. An exact solutio...

  16. MRI of the axial skeletal manifestations of ankylosing spondylitis

    Energy Technology Data Exchange (ETDEWEB)

    Levine, D.S.; Forbat, S.M.; Saifuddin, A. E-mail: asaifuddin@aol.com

    2004-05-01

    Magnetic resonance imaging (MRI) is a valuable tool in the imaging and assessment of patients with ankylosing spondylitis. MRI can demonstrate the acute and chronic changes of sacroiliitis, osteitis, discovertebral lesions, disc calcifications and ossification and arthopathic lesions, which characterize the disease, as well as the complications, which include fracture and the rare cauda equina syndrome. This article reviews the range of MRI findings commonly seen within the axial skeleton in patients with this condition.

  17. Simulation Method of Cumulative Flow without of Axial Stagnation Point

    Directory of Open Access Journals (Sweden)

    I. V. Minin

    2015-01-01

    Full Text Available The paper describes a developed analytical model of non-stationary formation of a cumulative jet without axial stagnation point. It shows that it is possible to control the weight, size, speed, and momentum of the jet with the parameters, which are not achievable in the classical mode of jet formation. Considered jet formation principle can be used to conduct laboratory simulation of astro-like plasma jets.

  18. Axial Compressor Stall and Surge Prediction by Measurements

    Directory of Open Access Journals (Sweden)

    H. Hönen

    1999-01-01

    Full Text Available The paper deals with experimental investigations and analyses of unsteady pressure distributions in different axial compressors. Based on measurements in a single stage research compressor the influence of increasing aerodynamic load onto the pressure and velocity fluctuations is demonstrated. Detailed measurements in a 14-stage and a 17-stage gas turbine compressor are reported. For both compressors parameters could be found which are clearly influenced by the aerodynamic load.

  19. Modeling Effects of Axial Extension on Arterial Growth and Remodeling

    OpenAIRE

    Valentín, A.; Humphrey, J. D.

    2009-01-01

    Diverse mechanical perturbations elicit arterial growth and remodeling responses that appear to optimize structure and function so as to achieve mechanical homeostasis. For example, it is well known that functional adaptations to sustained changes in transmural pressure and blood flow primarily affect wall thickness and caliber to restore circumferential and wall shear stresses toward normal. More recently, however, it has been shown that changes in axial extension similarly prompt dramatic c...

  20. Peripheral refraction with eye and head rotation with contact lenses.

    Science.gov (United States)

    Lopes-Ferreira, Daniela P; Neves, Helena I F; Faria-Ribeiro, Miguel; Queirós, António; Fernandes, Paulo R B; González-Méijome, José M

    2015-04-01

    To evaluate the impact of eye and head rotation in the measurement of peripheral refraction with an open-field autorefractometer in myopic eyes wearing two different center-distance designs of multifocal contact lenses (MFCLs). Nineteen right eyes from 19 myopic patients (average central M ± SD = -2.67 ± 1.66 D) aged 20-27 years (mean ± SD = 23.2 ± 3.3 years) were evaluated using a Grand-Seiko autorefractometer. Patients were fitted with one multifocal aspheric center-distance contact lens (Biofinity Multifocal D(®)) and with one multi-concentric MFCL (Acuvue Oasys for Presbyopia). Axial and peripheral refraction were evaluated by eye rotation and by head rotation under naked eye condition and with each MFCL fitted randomly and in independent sessions. For the naked eye, refractive pattern (M, J0 and J45) across the central 60° of the horizontal visual field values did not show significant changes measured by rotating the eye or rotating the head (p > 0.05). Similar results were obtained wearing the Biofinity D, for both testing methods, no obtaining significant differences to M, J0 and J45 values (p > 0.05). For Acuvue Oasys for presbyopia, also no differences were found when comparing measurements obtained by eye and head rotation (p > 0.05). Multivariate analysis did not showed a significant interaction between testing method and lens type neither with measuring locations (MANOVA, p > 0.05). There were significant differences in M and J0 values between naked eyes and each MFCL. Measurements of peripheral refraction by rotating the eye or rotating the head in myopic patients wearing dominant design or multi-concentric multifocal silicone hydrogel contact lens are comparable. Copyright © 2014 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  1. Simultaneous Rotational and Axial Flow of Nonlinear Fluids

    Science.gov (United States)

    Ashrafi, Nariman; Yektapour, Mehdi; Shafahi, Mehdi

    2017-11-01

    An axial flow is introduced to the rotational flow of pseudoplastic fluids in the gap between concentric cylinders. The outer cylinder is fixed while the inner one has simultaneous and independent rotational and translational motions. The fluid follows the Carreau-Bird model and mixed boundary conditions are imposed. The four-dimensional low-order equations resulted from Galerkin projection of the conservation of mass and momentum equations, includes highly non-linear terms in the velocity components. Without axial flow, stability of the base radial flow is lost to the vortex structure at a lower critical Taylor number, with increase of the fluid pseudoplasticity. The vortices imply onset of a supercritical bifurcation which occurs in the rotational flow of linear fluids as well. In contrast to the Newtonian case, pseudoplastic Taylor vortices lose their stability at a second critical Taylor number is reached a second critical number that corresponds to the onset of a Hopf bifurcation. The axial flow, caused by the translational motion of the inner cylinder advance each critical point on the bifurcation diagram. The flow field and viscosity maps are provided for major stability regions.

  2. HTS axial flux induction motor with analytic and FEA modeling

    Energy Technology Data Exchange (ETDEWEB)

    Li, S., E-mail: alexlee.zn@gmail.com; Fan, Y.; Fang, J.; Qin, W.; Lv, G.; Li, J.H.

    2013-11-15

    Highlights: •A high temperature superconductor axial flux induction motor and a novel maglev scheme are presented. •Analytic method and finite element method have been adopted to model the motor and to calculate the force. •Magnetic field distribution in HTS coil is calculated by analytic method. •An effective method to improve the critical current of HTS coil is presented. •AC losses of HTS coils in the HTS axial flux induction motor are estimated and tested. -- Abstract: This paper presents a high-temperature superconductor (HTS) axial-flux induction motor, which can output levitation force and torque simultaneously. In order to analyze the character of the force, analytic method and finite element method are adopted to model the motor. To make sure the HTS can carry sufficiently large current and work well, the magnetic field distribution in HTS coil is calculated. An effective method to improve the critical current of HTS coil is presented. Then, AC losses in HTS windings in the motor are estimated and tested.

  3. Imaging results and TOF studies with axial PET detectors

    CERN Document Server

    Joram, Christian

    2013-01-01

    We have developed a fully operational PET demonstrator setup which allows true 3D reconstruction of the 511 keV photons and therefore leads to practically parallax free images. The AX-PET concept is based on thin 100 mm long scintillation crystals (LYSO), axially oriented and arranged in layers around the held of view. Layers of wavelength shifting plastic strips mounted in between the crystal layers give the axial coordinate. Both crystals and WLS strips are individually read out by G-APD (SiPM) photodetectors. The Fully scalable concept overcomes the dilemma of sensitivity versus spatial resolution which is inherent to classical PET designs. A demonstrator set-up based on two axial modules was exhaustively characterized using point-like sources, phantoms filled with radiotracer and finally rats and a mouse. The results entirely meet the performance expectations ( <2 mm FWHM in all three coordinates over the complete held of view) and also demonstrated the ability to include Compton interactions (inter-cr...

  4. The New Performance Calculation Method of Fouled Axial Flow Compressor

    Directory of Open Access Journals (Sweden)

    Huadong Yang

    2014-01-01

    Full Text Available Fouling is the most important performance degradation factor, so it is necessary to accurately predict the effect of fouling on engine performance. In the previous research, it is very difficult to accurately model the fouled axial flow compressor. This paper develops a new performance calculation method of fouled multistage axial flow compressor based on experiment result and operating data. For multistage compressor, the whole compressor is decomposed into two sections. The first section includes the first 50% stages which reflect the fouling level, and the second section includes the last 50% stages which are viewed as the clean stage because of less deposits. In this model, the performance of the first section is obtained by combining scaling law method and linear progression model with traditional stage stacking method; simultaneously ambient conditions and engine configurations are considered. On the other hand, the performance of the second section is calculated by averaged infinitesimal stage method which is based on Reynolds’ law of similarity. Finally, the model is successfully applied to predict the 8-stage axial flow compressor and 16-stage LM2500-30 compressor. The change of thermodynamic parameters such as pressure ratio, efficiency with the operating time, and stage number is analyzed in detail.

  5. Multi technical analysis of wear mechanisms in axial piston pumps

    Science.gov (United States)

    Schuhler, G.; Jourani, A.; Bouvier, S.; Perrochat, J.-M.

    2017-05-01

    Axial piston pumps convert a motor rotation motion into hydraulic or pneumatic power. Their compactness and efficiency of approximately 0.9 make them suitable for actuation applications especially in aeronautics. However, they suffer a limited life due to the wear of their components. In the literature, studies of axial piston pumps deal with contact between its different elements under lubrication conditions. Nevertheless, they are more focused on analytic or numerical approaches. This study consists in an experimental analysis of worn pump components to highlight and understand wear mechanisms. Piston shoes are central components in the axial piston pump since they are involved in three tribological contacts. These three contacts are thereby studied: piston shoes/swashplate, piston shoes/pistons and piston shoes/shoes hold down plate (SHDP). To perform this analysis, helicopter hydraulic pumps after different operating times have been studied. The wear damage mechanisms and wear debris are analysed using SEM observations. 3D surface roughness measurements are then used to characterize worn surfaces. The observations reveal that in the contact between shoes and swashplate, the main wear mechanism is three-body abrasive wear due to coarse carbides removal. Between shoes and pistons, wear occurs in a less severe way and is mainly due to the debris generated in the first contact and conveyed by the lubricating fluid. In the third contact, the debris are also the prime cause of the abrasive wear and the generation of deep craters in the piston shoes.

  6. Servo control system construction for CBHD radial and axial tracking

    Science.gov (United States)

    Cui, Yingchao; Cheng, Xuemin; Ma, Jianshe; Hou, Xinnan

    2010-11-01

    CBHD (China Blue High Definition Disc) is a high-definition optical disc standard with Chinese independent intellectual property. Compared with DVD optical pick-up, CBHD optical pick-up, key component of CBHD player, has significant improvement in the channel bit rate and certain reduction in acceptable tolerance range for disk tilt, etc. This paper specifies the servo control system construction for the CBHD radial tracing and axial tracking. This servo control system should ensure the optical beam of OPU focusing on the Disc plane and following the track of CBHD channel accurately. According to the expected radial/axial maximum acceleration and the limitation of emax, an open-loop transfer function specifying the servo system for axial and radial tracking is introduced. The corresponding servo control algorithm including IIR filter based on the above-mentioned transfer function is theoretically analyzed and numerically simulated by MATLAB. Because optical pick-ups are different in dynamic properties and its digital circuit exist quantization error, time delay nonlinearity, etc, the tuning of IIR parameters is laborious and time-consuming. Thus a experimental platform for CBHD optical pick-up servo system are designed in this paper, and an user-friendly interface for IIR parameters adjustment is given. Experimental results showed that this control system has good servo characteristics in time-domain and frequency-domain.

  7. HEAD AND NECK SURGERY

    African Journals Online (AJOL)

    Chart review was possible for 320 consecutive patients from. January 1995 to December 2008. Demographic ... Conclusion: Standardised parotidectomy is a safe operation, with a low complication rate. S Afr J Surg 2015;53(3&4) ... relates to the inflammatory process or an aggressive tumour. Rapidly evolving facial nerve ...

  8. Multiplanar reconstructed CT images increased depiction of intracranial hemorrhages in pediatric head trauma

    Energy Technology Data Exchange (ETDEWEB)

    Langford, Stacey; Panigrahy, Ashok; Narayanan, Srikala; Hwang, Misun; Fitz, Charles; Flom, Lynda; Lee, Vincent Kyu; Zuccoli, Giulio [Children' s Hospital of Pittsburgh of UPMC, Department of Radiology, Section of Neuroradiology, Pittsburgh, PA (United States)

    2015-12-15

    The benefits of multiplanar reconstructed images (MPR) of unenhanced axial head computed tomography (CT) data have not been established in trauma patients younger than 3 years old, a population in which a reliable history and physical examination may be most difficult. We retrospectively evaluated unenhanced head CTs in pediatric trauma patients to investigate the various benefits of MPR in this age group. A total of 221 unenhanced head CTs performed for any case of head trauma (HT) on children younger than 3 years old were independently reviewed by two radiologists. Studies were reviewed first in the standard axial plane alone and then with the addition of MPR. Reviewers were asked to determine if the MPR affected the ability to make findings of hemorrhage, incidental findings, and artifacts. MPR improved the detection of hemorrhage in 14 cases (6.5 %, p-value < 0.01) and incidental findings in five cases (2.3 %, p-value < 0.05) as well as helped prove artifacts in five cases (2.3 %, p-value < 0.05). Routine use of MPR in HT patients younger than 3 years old has the potential to increase the detection of acute and incidental imaging findings. (orig.)

  9. HEADS UP : Sensorimotor control of the head-neck system

    NARCIS (Netherlands)

    Forbes, P.A.

    2014-01-01

    Head-neck stabilization is inherently challenging even when stationary, requiring constant vigilance to counter the downward pull of gravity. It involves a highly complex biomechanical system comprised of a large mass (the head) balanced on top of seven vertebrae (the neck), that are in turn

  10. Experimental Study of Axially Tension Cold Formed Steel Channel Members

    Science.gov (United States)

    Apriani, Widya; Lubis, Fadrizal; Angraini, Muthia

    2017-12-01

    Experimental testing is commonly used as one of the steps to determine the cause of the collapse of a building structure. The collapse of structures can be due to low quality materials. Although material samples have passed laboratory tests and the existing technical specifications have been met but there may be undetected defects and known material after failure. In this paper will be presented Experimental Testing of Axially Tension Cold Formed Steel Channel Members to determine the cause of the collapse of a building roof truss x in Pekanbaru. Test of tensile strength material cold formed channel sections was performed to obtain the main characteristics of Cold Formed steel material, namely ultimate tensile strength loads that can be held by members and the yield stress possessed by channel sections used in construction. Analysis of axially tension cold formed steel channel section presents in this paper was conducted through experimental study based on specificationsAnnualBook of ASTM Standards: Metal Test methods and Analitical Procedures, Section 3 (1991). The result of capacity loads experimental test was compared with design based on SNI 03-7971-2013standard of Indonesia for the design of cold formed steel structural members. The results of the yield stress of the material will be seen against the minimum allowable allowable stress range. After the test, the percentace of ultimate axial tension capacity theory has a result that is 16.46% larger than the ultimate axial tension capacity experimental. When compared with the load that must be borne 5.673 kN/m it can be concluded that 2 specimens do not meet. Yield stress of member has fulfilled requirement that wass bigger than 550 MPa. Based on the curve obtained ultimate axial tension capacity theory, results greater than experimental. The greatest voltage value (fu) is achieved under the same conditions as its yield stress. For this specimen with a melting voltage value fy = 571.5068 MPa has fulfilled the

  11. Numerical simulation and comparative analysis of flow field in axial blood pumps.

    Science.gov (United States)

    Peng, Yuhua; Wu, Yaqin; Tang, Xiaoying; Liu, Weifeng; Chen, Duanduan; Gao, Tianxin; Xu, Yong; Zeng, Yanjun

    2014-05-01

    The objective study was to estimate the rheological properties and physiological compatibility of the blood pump by simulating the internal flow field of the blood pump. In this study we use computational fluid dynamics method to simulate and analyse two models of axial blood pumps with a three-blade diffuser and a six-blade diffuser, named pump I and pump II, respectively, and to compare the flow patterns of these two kinds of blood pumps while both of them satisfy the conditions of the normal human blood differential pressure and blood flow. Results indicate that (i) the high shear force occurs between the diffuser and the rotor in which the crucial place leads to haemolysis and (ii) under the condition of 100 mmHg pressure head and 5 l/min flow rate, the difference between the two kinds of blood pumps, as far as the haemolytic performance is concerned, is notable. The haemolysis index of the two pumps is 0.32% and 0.2%. In conclusion, the performance of the blood pump is influenced by the diffusers' blade number. Pump II performed better than pump I, which can be the basic model for blood pump option.

  12. Behaviour of Load-Bearing Components of a Cushioned Composite Piled Raft Foundation Under Axial Loading

    Directory of Open Access Journals (Sweden)

    Sharma V. J.

    2014-12-01

    Full Text Available In the last decade piled raft foundations have been widely used around the world as intermediate foundation systems between piles and rafts to control the settlement of foundations. However, when those piles are structurally connected to rafts, relatively high axial stresses develop in relatively small numbers of piles, which are often designed to fully mobilize their geotechnical capacities. To avoid a concentration of stress at the head of piles in a traditional piled raft foundation, the raft is disconnected from the piles, and a cushion is introduced between them. Also, to tackle an unfavourable soil profile for a piled raft foundation, the conventional piled raft has been modified into a cushioned composite piled raft foundation, where piles of different materials are used. In the current study the behavior of cushioned foundation components, which transfer the load from the structure to the subsoil, are analyzed in detail, i.e., the thickness of the raft, the length of a long pile and the modulus of a flexible pile.

  13. Neanderthal axial and appendicular remains from Moula-Guercy, Ardèche, France.

    Science.gov (United States)

    Mersey, Ben; Brudvik, Kyle; Black, Michael T; Defleur, Alban

    2013-12-01

    Excavations carried out during the 1990s at Moula-Guercy cave Ardèche, France, yielded 108 hominid specimens dating to 100-120 Ka. In this paper, we describe and compare the 39 axial and appendicular specimens not including hand and foot bones. Among these remains are a large adult femur, several clavicles, a likely antimeric pair of radial heads, and a nearly complete superior pubic ramus. Analyses of this material indicate a clear affinity with Neanderthals by the presence of large and robust muscle attachments, thick long bone cortices, a long pubic ramus, and a superoinferiorly flattened clavicle shaft. The recovered remains reveal the presence of a mature male, a smaller mature individual, possibly a reproductive age female, an immature individual of age 10-12, and a second immature individual of age 4. Future analyses on the Moula-Guercy remains will illuminate ties to other known Neanderthal populations and contribute to the ongoing debate over the relative rate of Neanderthal metric growth. Copyright © 2013 Wiley Periodicals, Inc.

  14. Axial pattern flap based on a cutaneous branch of the facial artery in cats.

    Science.gov (United States)

    Milgram, Joshua; Weiser, Maya; Kelmer, Efrat; Benzioni, Hadas

    2011-04-01

    To describe the cutaneous portion of the facial artery in cats and an axial pattern flap based on a branch of this artery. Ex vivo study. Cat cadavers (n=12). The common carotid artery was identified, cannulated, and infused with methylene blue to assist in the identification of the facial artery, which was subsequently cannulated and selectively infused with methylene blue. The main trunk of the artery and its branches were dissected. The extent of blue coloration of the skin was evaluated on the contralateral side of the same specimen after infusing methylene blue into the facial artery. In 4 specimens, the flap was raised along previously defined borders and adequacy of perfusion was evaluated. The area of skin perfused by the facial artery extended from the lower eyelid dorsally, to the angularis oris cranially, and the wing of the atlas caudally. Borders of the skin flap were defined on the basis of the anatomic dissection and skin coloration after selective infusion of the facial artery with methylene blue. A skin flap of 6 cm × 3.4 cm, based on the first caudally directed cutaneous branch of the facial artery was shown to be well perfused. The viability of this flap was confirmed in a clinical case. The facial artery flap is useful for repair of skin defects of the head in cats. © Copyright 2011 by The American College of Veterinary Surgeons.

  15. A three-step calibration method for tri-axial field sensors in a 3D magnetic digital compass

    Science.gov (United States)

    Zhu, Xiaoning; Zhao, Ta; Cheng, Defu; Zhou, Zhijian

    2017-04-01

    In a 3D magnetic compass, it is important to calibrate the tri-axial magnetometers and accelerometers so the compass will provide accurate heading and attitude information. Previous researchers have used two methods to calibrate these two field sensors separately, i.e. the classic independent ellipsoid fitting method and the independent dot product invariant method, respectively. Both methods are easy to use, and no highly accurate, external equipment is required. However, self-calibration with ellipsoid fitting has the disadvantage that it interfuses an orthogonal matrix, and the dot product invariant method requires the use of pre-calibrated internal field sensors, which may be unavailable in many cases. In this paper, we have introduced and unified an error model of two tri-axial field sensors. Accordingly, the orthogonal matrix caused by ellipsoid fitting was mathematically proved to be the combination of two sources, the mounting misalignment and the rotation misalignment. Moreover, a new method, which we call optimal resultant vector, was proposed to further calibrate multi-sensor systems on the basis of ellipsoid fitting and dot product invariant methods, establishing a new, three-step calibration method. The superiority of the proposed method over the state-of-the-art approaches were demonstrated by simulations and a 3D compass experiment.

  16. Experimental studies into the dependences of the axial lead coolant pump performance on the impeller cascade parameters

    Directory of Open Access Journals (Sweden)

    A.V. Beznosov

    2017-06-01

    Full Text Available The paper presents results of experimental studies into the dependences of the axial lead coolant pump performance (delivery, head, efficiency on the impeller cascade parameters, including the number of blades, the cascade blade angle and the cascade solidity. The studies were conducted as applied to conditions of small and medium sized plants based on lead cooled fast neutron reactors with horizontal steam generators. The designs of such plants are now in the process of elaboration at Nizhny Novgorod State Technical University (NNSTU. The studies were conducted at NNSTU's FT-4 test facility at a lead coolant temperature of 440–500°C. In the process of investigations, the number of blades in the form of flat plates was 3, 4, 6 and 8, the cascade blade angle was in a range of 9–43°, and the cascade solidity (0.6–1.2 was changed by changing the blade section chord length. The shaft speed of the NNSTU's NSO-01 pump, onto which changeable impellers were installed, was changed in steps of 100 rev/min in an interval of 600–1100 rev/min. The blade diameter was about 200mm, and the maximum lead coolant flow rate in the course of the tests reached ∼2000t/h. The performance of 27 impellers was investigated. It is recommended that the investigation results should be used in design of axial HLMC pumps.

  17. Exit blade geometry and part-load performance of small axial flow propeller turbines: An experimental investigation

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Punit; Nestmann, Franz [Institute for Water and River Basin Management (IWG), University of Karlsruhe, Kaiser Str. 12, D 76128 Karlsruhe (Germany)

    2010-09-15

    A detailed experimental investigation of the effects of exit blade geometry on the part-load performance of low-head, axial flow propeller turbines is presented. Even as these turbines find important applications in small-scale energy generation using micro-hydro, the relationship between the layout of blade profile, geometry and turbine performance continues to be poorly characterized. The experimental results presented here help understand the relationship between exit tip angle, discharge through the turbine, shaft power, and efficiency. The modification was implemented on two different propeller runners and it was found that the power and efficiency gains from decreasing the exit tip angle could be explained by a theoretical model presented here based on classical theory of turbomachines. In particular, the focus is on the behaviour of internal parameters like the runner loss coefficient, relative flow angle at exit, mean axial flow velocity and net tangential flow velocity. The study concluded that the effects of exit tip modification were significant. The introspective discussion on the theoretical model's limitation and test facility suggests wider and continued experimentation pertaining to the internal parameters like inlet vortex profile and exit swirl profile. It also recommends thorough validation of the model and its improvement so that it can be made capable for accurate characterization of blade geometric effects. (author)

  18. Head-head interactions of resting myosin crossbridges in intact frog skeletal muscles, revealed by synchrotron x-ray fiber diffraction.

    Directory of Open Access Journals (Sweden)

    Kanji Oshima

    Full Text Available The intensities of the myosin-based layer lines in the x-ray diffraction patterns from live resting frog skeletal muscles with full thick-thin filament overlap from which partial lattice sampling effects had been removed were analyzed to elucidate the configurations of myosin crossbridges around the thick filament backbone to nanometer resolution. The repeat of myosin binding protein C (C-protein molecules on the thick filaments was determined to be 45.33 nm, slightly longer than that of myosin crossbridges. With the inclusion of structural information for C-proteins and a pre-powerstroke head shape, modeling in terms of a mixed population of regular and perturbed regions of myosin crown repeats along the filament revealed that the myosin filament had azimuthal perturbations of crossbridges in addition to axial perturbations in the perturbed region, producing pseudo-six-fold rotational symmetry in the structure projected down the filament axis. Myosin crossbridges had a different organization about the filament axis in each of the regular and perturbed regions. In the regular region that lacks C-proteins, there were inter-molecular interactions between the myosin heads in axially adjacent crown levels. In the perturbed region that contains C-proteins, in addition to inter-molecular interactions between the myosin heads in the closest adjacent crown levels, there were also intra-molecular interactions between the paired heads on the same crown level. Common features of the interactions in both regions were interactions between a portion of the 50-kDa-domain and part of the converter domain of the myosin heads, similar to those found in the phosphorylation-regulated invertebrate myosin. These interactions are primarily electrostatic and the converter domain is responsible for the head-head interactions. Thus multiple head-head interactions of myosin crossbridges also characterize the switched-off state and have an important role in the regulation

  19. Womanhood in Bessie Head's fiction

    African Journals Online (AJOL)

    confronted with gender discrimination in addition ;to the racial and ethnic marginality she had suffered since childhood. When the discovery of. Margaret's Basarwa origins culminate in the decision to get rid of her, Head points to the multiplicity of her problems. Head demonstrates that Margaret's womanhood comes into ...

  20. Analytical modelling of soccer heading

    Indian Academy of Sciences (India)

    Heading occur frequently in soccer games and studies have shown that repetitive heading of the soccer ball could result in degeneration of brain cells and lead to mild traumatic brain injury. This study proposes a two degree-of-freedom linear mathematical model to study the impact of the soccer ball on the brain. The model ...

  1. The head-mounted microscope.

    Science.gov (United States)

    Chen, Ting; Dailey, Seth H; Naze, Sawyer A; Jiang, Jack J

    2012-04-01

    Microsurgical equipment has greatly advanced since the inception of the microscope into the operating room. These advancements have allowed for superior surgical precision and better post-operative results. This study focuses on the use of the Leica HM500 head-mounted microscope for the operating phonosurgeon. The head-mounted microscope has an optical zoom from 2× to 9× and provides a working distance from 300 mm to 700 mm. The headpiece, with its articulated eyepieces, adjusts easily to head shape and circumference, and offers a focus function, which is either automatic or manually controlled. We performed five microlaryngoscopic operations utilizing the head-mounted microscope with successful results. By creating a more ergonomically favorable operating posture, a surgeon may be able to obtain greater precision and success in phonomicrosurgery. Phonomicrosurgery requires the precise manipulation of long-handled cantilevered instruments through the narrow bore of a laryngoscope. The head-mounted microscope shortens the working distance compared with a stand microscope, thereby increasing arm stability, which may improve surgical precision. Also, the head-mounted design permits flexibility in head position, enabling operator comfort, and delaying musculoskeletal fatigue. A head-mounted microscope decreases the working distance and provides better ergonomics in laryngoscopic microsurgery. These advances provide the potential to promote precision in phonomicrosurgery. Copyright © 2011 The American Laryngological, Rhinological, and Otological Society, Inc.

  2. Design and axial optimization of nuclear fuel for BWR reactors; Diseno y optimizacion axial de combustible nuclear para reactores BWR

    Energy Technology Data Exchange (ETDEWEB)

    Garcia V, M.A

    2006-07-01

    In the present thesis, the modifications made to the axial optimization system based on Tabu Search (BT) for the axial design of BWR fuel type are presented, developed previously in the Nuclear Engineering Group of the UNAM Engineering Faculty. With the modifications what is mainly looked is to consider the particular characteristics of the mechanical design of the GE12 fuel type, used at the moment in the Laguna Verde Nucleo electric Central (CNLV) and that it considers the fuel bars of partial longitude. The information obtained in this thesis will allow to plan nuclear fuel reloads with the best conditions to operate in a certain cycle guaranteeing a better yield and use in the fuel burnt, additionally people in charge in the reload planning will be favored with the changes carried out to the system for the design and axial optimization of nuclear fuel, which facilitate their handling and it reduces their execution time. This thesis this developed in five chapters that are understood in the following way in general: Chapter 1: It approaches the basic concepts of the nuclear energy, it describes the physical and chemical composition of the atoms as well as that of the uranium isotopes, the handling of the uranium isotope by means of the nuclear fission until arriving to the operation of the nuclear reactors. Chapter 2: The nuclear fuel cycle is described, the methods for its extraction, its conversion and its enrichment to arrive to the stages of the nuclear fuel management used in the reactors are described. Beginning by the radial design, the axial design and the core design of the nuclear reactor related with the fuel assemblies design. Chapter 3: the optimization methods of nuclear fuel previously used are exposed among those that are: the genetic algorithms method, the search methods based on heuristic rules and the application of the tabu search method, which was used for the development of this thesis. Chapter 4: In this part the used methodology to the

  3. 49 CFR 572.112 - Head assembly.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 7 2010-10-01 2010-10-01 false Head assembly. 572.112 Section 572.112... 50th Percentile Male § 572.112 Head assembly. The head assembly consists of the head (drawing 78051-61X...) accelerometers that are mounted in conformance to § 572.36 (c). (a) Test procedure. (1) Soak the head assembly in...

  4. 49 CFR 572.192 - Head assembly.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 7 2010-10-01 2010-10-01 false Head assembly. 572.192 Section 572.192... Dummy, Small Adult Female § 572.192 Head assembly. (a) The head assembly consists of the head (180-1000...) of this section, the head assembly shall meet performance requirements specified in paragraph (c) of...

  5. Microstructural study of an ODS stainless steel obtained by Hot Uni-axial Pressing

    Science.gov (United States)

    Sornin, D.; Grosdidier, T.; Malaplate, J.; Tiba, I.; Bonnaillie, P.; Allain-Bonasso, N.; Nunes, D.

    2013-08-01

    This study focuses on the consolidation of an ODS Fe-14Cr-1W-0.3Ti-0.3Y2O3 alloy obtained by powder metallurgy. The powder was sintered for 1 h at 1100 °C in a soft steel can and compacted by Hot Uni-axial Pressing (HUP) under 900 MPa within less than 5 s before air cooling. The HUPped material microstructure is prospected to determine relative density as well as microstructure and nano-precipitation. The HUP, which mimics the early stage of hot extrusion (HE), produces a fully dense metallurgical state. The HUPped microstructure is shown to be rather similar to the one obtained by HIPping for equivalent dwell time at high temperature. In both cases heterogeneous grain size microstructure was obtained. It is shown that the bigger grains come from static recrystallization occurring during the dwell time in furnace. Compared to HIP, the effect of the HUP is mainly to introduce intra-granular misorientations within these large recrystallized grains. During Hot Unidirectional Pressing the initially loose powder is fully consolidated. The relative density is rather similar to the HE and HIP process. Even with a uni-axial loading the HUPed material is homogeneous and does not presents any gradients of hardness. The obtained microstructure for the HUPed shows a bimodal grain size distribution and precipitates strings at grain boundaries. This material can be compared to HIP of similar composition grades [10]. Large grains are issued from an incomplete static recrystallization. Precipitation of nano-clusters is very similar for HUPed and HE materials. Nanometer scale precipitates are observed both within the large and small grains. One of the effects of the HUP compared to pure heat treatment is that the large grains that recrystallized during the early stages of the heat treatment present significant internal crystallographic misorientations. This is due to the plastic strain generated by the rapid compaction during HUP consolidation process.

  6. Atlanto-axial rotatory fixation caused by spontaneous intracerebral haemorrhage in a child.

    Science.gov (United States)

    Kombogiorgas, Dimitris; Hussain, Ihsan; Sgouros, Spyros

    2006-09-01

    Atlanto-axial rotatory fixation is rare in children and usually associated with upper respiratory tract infection or trauma. We present a patient who developed the condition acutely as a consequence of rapidly evolving hemiplegia secondary to intracerebral haemorrhage. A previously well 12-year-old boy suddenly developed left hemiparesis within 30 min. Soon after, he developed painful torticollis. On examination, a dense left hemiplegia was associated with left facial and hypoglossal weakness. On computerised tomography (CT) scan there was an intracerebral haemorrhage in the deep aspect of the right frontal lobe in the corona radiata, with extension in the ventricular system. The plain radiographs of the cervical spine, and CT scan later, confirmed the presence of C1-C2 rotatory subluxation. The haematoma was aspirated stereotactically through a burr hole, and at the same session, the subluxation was reduced by manipulation and traction of the cervical spine. The patient was treated with a hard collar. The torticollis did not recur. The hemiparesis resolved within 6 months. A subsequent magnetic resonance imaging and magnetic resonance angiography scan indicated possible arterio-venous malformation (AVM) at the site of the haemorrhage, which was confirmed with digital subtraction angiography. The AVM was surgically excised 1 year from the original haemorrhage. In the absence of any other predisposing factor, it is postulated that the acute atlanto-axial rotatory subluxation was secondary to the acute loss of muscular tone due to the acute hemiparesis. This explains that the subluxation has not recurred a year after, while the hemiparesis has completely resolved.

  7. Positional cloning of the gene for pre-axial polydactyly

    Energy Technology Data Exchange (ETDEWEB)

    Heutink, P.; Breedveld, G.J.; Zguricas, J. [Erasmus Univ., Rotterdam (Netherlands)] [and others

    1994-09-01

    Pre-axial polydactyly can occur as an isolated anomaly, in association with other abnormalities of the hand or as a component of complex developmental disorders. We recently localized the gene for pre-axial polydactyly to the most distal part of chromosome 7q. Identification and characterization of the gene defect and studies of the expression pattern during embryonic development may help clarify questions about the role of this gene in other developmental processes than those in hands. A key element involved in the formation of the separate digits of the developing limb is the apical ectodermal ridge (AER). In the AER and in the adjacent mesoderm, homeobox genes as well as genes regulating programmed cell death, growth factors or receptors are expressed. Disruption of any of these genes might potentially interfere with normal differentiation. How these genes interact and which genes are involved in the formation of the five digits is still largely unknown. We have ascertained additional families and performed haplotype analysis to define the critical region. Currently, we are developing new STS polymorphic markers to narrow down this critical region. YAC and cosmid contigs are being developed. On the syntenic region of human 7q36, the mouse chromosome 5p, a mutation has been localized that resembles the human polydactyly phenotype. Hx is a candidate gene for the disease gene in the families studied. YACs from the critical regions of the human and mouse phenotypes are being used to identify conserved sequences. These sequences are used to isolate cDNAs which will be used for mutation analysis in human family material in order to isolate the responsible gene for pre-axial polydactyly. Our most recent results will be presented.

  8. Renormalisation group flows for gauge theories in axial gauges

    CERN Document Server

    Litim, Daniel F; Litim, Daniel F.; Pawlowski, Jan M.

    2002-01-01

    Gauge theories in axial gauges are studied using Exact Renormalisation Group flows. We introduce a background field in the infrared regulator, but not in the gauge fixing, in contrast to the usual background field gauge. It is shown how heat-kernel methods can be used to obtain approximate solutions to the flow and the corresponding Ward identities. Expansion schemes are discussed, which are not applicable in covariant gauges. As an application, we derive the one-loop effective action for covariantly constant field strength, and the one-loop beta-function for arbitrary regulator.

  9. Test Procedure for Axially Loaded Piles in Sand

    DEFF Research Database (Denmark)

    Thomassen, Kristina

    The test procedure described in the following is used when examining the effects of static or cyclic loading on the skin friction of an axially loaded pile in dense sand. The pile specimen is only loaded in tension to avoid any contribution from the base resistance. The pile dimensions are chosen...... to resemble full scale dimension of piles used in offshore pile foundations today. In this report is given a detailed description of the soil preparation and pile installation procedures as well data acquisition methods....

  10. Axial currents, supercurrents and anomalies in supersymmetric QED

    Energy Technology Data Exchange (ETDEWEB)

    Clark, T.E.

    1979-01-01

    The currents associated with the superconformal symmetries are defined as moments of the supercurrent, V/sub ..mu... All of the current (non-) conservation equations are known once the generalized trace of the supercurrent, D/sup ..cap alpha../V/sub ..cap alpha cap alpha../, is found. The superconformal anomalies are shown to have coefficients given by ..beta.. of the Callan-Symanzik equation. In super QED there is an additional U(1) axial current whose anomaly has a coefficient with no radiative corrections. 5 references.

  11. Time Dependent and Steady Uni-axial Elongational Viscosity

    DEFF Research Database (Denmark)

    Nielsen, Jens K.; Rasmussen, Henrik Koblitz; Hassager, Ole

    2005-01-01

    Here we present measurements of transient and steady uni-axial elongational viscosity, using the Filament Stretching Rheometer1 or FSR1 (see Fig. 1) of the following melts: Four narrow MMD polystyrene (PS) samples with weight-average molar mass Mw in the range of 50k to 390k. Three different bi......-disperse samples, mixed from the narrow MMD PS. Two low-density polyethylene (LDPE) melts (Lupolen 1840D and 3020D). A steady-state viscosity was kept for 1-2.5 Hencky strain units in all measurements....

  12. Electromagnetic Reciprocal Cloak with Only Axial Material Parameter Spatially Variant

    Directory of Open Access Journals (Sweden)

    Jing Jing Yang

    2012-01-01

    Full Text Available Reciprocal cloak is an intriguing metamaterial device, in which a hidden antenna or a sensor can receive electromagnetic irradiation from the outside but its presence will not be detected. Based on transformation optics, a cylindrical electromagnetic reciprocal cloak with only axial parameter varying with radius is designed and validated by full wave simulation. When two dispersive reciprocal cloaks are put together, they do not interfere with each other. Our work demonstrates the electromagnetic compatibility (EMC ability of the reciprocal cloak which is very important in multi antenna and sensor design.

  13. Calibration and Reconstruction in Non-Central Axial Catadioptric Systems

    OpenAIRE

    Perdigoto, Luís Miguel Ramos

    2015-01-01

    Tese de doutoramento em Engenharia Electrotécnica e de Computadores, no ramo de Automação e Robótica, apresentada ao Departamento de Engenharia Eletrotécnica e de Computadores da Faculdade de Ciências e Tecnologia da Universidade de Coimbra Esta tese de doutoramento estuda sistemas de visão axiais catadióptricos nãocentrais, ou seja, sistemas com um espelho de simetria axial e uma câmara pinhole com o centro ótico pertencente ao eixo do espelho. São propostos métodos originais par...

  14. Plasticity around an Axial Surface Crack in a Cylindrical Shell

    DEFF Research Database (Denmark)

    Krenk, Steen

    1979-01-01

    field in an axially cracked cylindrical shell arising from use of classical eighth order shallow shell theory is removed when use is made of a tenth order shell theory which accounts for transverse shear deformations. Although the membrane stresses are only moderately affected, the influence...... and Ratwani,3–5 it generalises Dugdale's assumption of a concentrated yield zone in the plane of the crack but, contrary to that model, transverse shear effects are included and a continuous stress distribution is assumed in the yield zone. The inherent difficulties arising from the use of shell theory...

  15. Human axial chromatic aberration found not to decline with age.

    Science.gov (United States)

    Ware, C

    1982-01-01

    Millodot (1976) reported a dramatic decline in the amount of axial chromatic aberration of the human eye with age. The present study represents a failure to replicate that finding using a more standard procedure. No difference in chromatic aberration was found between a young and an older group of observers. Also, the chromatic aberrations of two observers which had been measured 25 years previously showed no decline when these measurements were repeated, even though their ages at first and second testing straddled the period over which Millodot reported the most change in chromatic aberration.

  16. Dynamic Response of Axially Loaded Euler-Bernoulli Beams

    DEFF Research Database (Denmark)

    Bayat, M.; Barari, Amin; Shahidi, M.

    2011-01-01

    The current research deals with application of a new analytical technique called Energy Balance Method (EBM) for a nonlinear problem. Energy Balance Method is used to obtain the analytical solution for nonlinear vibration behavior of Euler-Bernoulli beams subjected to axial loads. Analytical...... expressions for geometrically nonlinear vibration of beams are provided. The effect of vibration amplitude on the nonlinear frequency is discussed. Comparison between Energy Balance Method results and those available in literature demonstrates the accuracy of this method. In Energy Balance Method contrary...

  17. Design of an instrumented model pile for axial cyclic loading

    OpenAIRE

    Rakotonindriana, Julio; Le Kouby, Alain; Buttigieg, Stéphane; Derkx, François; Thorel, Luc; Garnier, Jacques

    2010-01-01

    To study the behavior of a pile foundation under a cyclic axial loading, an instrumented pile was developed for centrifuge tests. The design of the instrumented pile takes into account some constraints due to centrifuge tests and allows us to install the pile in flight. The instrumentation of the pile permits the measure of the skin friction at five depths and the tip resistance. Some static and cyclic tests have been made and show the efficiency of the instrumented pile in capturing the main...

  18. Tunable axial potentials for atom-chip waveguides

    Science.gov (United States)

    Stickney, James A.; Imhof, Eric; Kasch, Brian; Kroese, Bethany; Crow, Jonathon A. R.; Olson, Spencer E.; Squires, Matthew B.

    2017-11-01

    We present a method for generating precise, dynamically tunable magnetic potentials that can be described by a polynomial series along the axis of a cold-atom waveguide near the surface of an atom chip. With a single chip design consisting of several wire pairs, various axial potentials can be created by changing the ratio of the currents in the wires, including double wells, triple wells, and pure harmonic traps with suppression of higher-order terms. We use this method to design and fabricate a chip with modest experimental requirements. Finally, we use the chip to demonstrate a double-well potential.

  19. Discrimination of hydrogen-bonded complexes with axial chirality

    Science.gov (United States)

    Alkorta, Ibon; Elguero, José

    2002-10-01

    The chiral self-discrimination of twelve molecules showing axial chirality has been studied. They included peroxides, hydrazines, carboxylic acids, amides, and allenes. The homo and heterochiral dimers of the selected compounds, that present two hydrogen bonds, have been studied by means of density functional theory (B3LYP/6-31+G**) and ab initio (MP2/6-31+G** and MP2/6-311++G**) methods. The energetic differences found for the complexes of each compound have been rationalized based on their electron density maps and the natural bond orbital analysis. In some cases, intermolecular oxygen-oxygen interactions have been found and interpreted as additional stabilizing contacts.

  20. Axial dispersion via shear-enhanced diffusion in colloidal suspensions

    KAUST Repository

    Griffiths, I. M.

    2012-03-01

    The familiar example of Taylor dispersion of molecular solutes is extended to describe colloidal suspensions, where the fluctuations that contribute to dispersion arise from hydrodynamic interactions. The generic scheme is illustrated for a suspension of particles in a pressure-driven pipe flow, with a concentration-dependent diffusivity that captures both the shear-induced and Brownian contributions. The effect of the cross-stream migration via shear-induced diffusion is shown to dramatically reduce the axial dispersion predicted by classical Taylor dispersion for a molecular solute. Analytic and numerical solutions are presented that illustrate the effect of the concentration dependence of this nonlinear hydrodynamic mechanism. Copyright © EPLA, 2012.

  1. SUSY approach to Pauli Hamiltonians with an axial symmetry

    Energy Technology Data Exchange (ETDEWEB)

    Ioffe, M V; Kuru, S; Negro, J; Nieto, L M [Departamento de Fisica Teorica, Atomica y Optica, Universidad de Valladolid, 47071 Valladolid (Spain)

    2006-06-02

    A two-dimensional Pauli Hamiltonian describing the interaction of a neutral spin-1/2 particle with a magnetic field having axial and second-order symmetries is considered. After separation of variables, the one-dimensional matrix Hamiltonian is analysed from the point of view of supersymmetric quantum mechanics. Attention is paid to the discrete symmetries of the Hamiltonian and also to the Hamiltonian hierarchies generated by intertwining operators. The spectrum is studied by means of the associated matrix shape invariance. The relation between the intertwining operators and the second-order symmetries is established, and the full set of ladder operators that complete the dynamical algebra is constructed.

  2. Remotely scanned multiphoton temporal focusing by axial grism scanning.

    Science.gov (United States)

    Dana, Hod; Shoham, Shy

    2012-07-15

    A simple technique for remote scanning of the focal plane in temporal focusing multiphoton microscopy is demonstrated both theoretically and experimentally. A new on-axis light propagation optical setup design enables this scanning, which was considered not feasible in previous studies. The focal plane is axially displaced by the movement of a remote optical device, consisting of a double prism grating, and optionally a cylindrical lens. The displacement is linear, and its slope is inversely proportional to the square of the optical system's magnification.

  3. Chronology and evolution of a fluvial/canyon connection around the Last Glacial Maximum: The Bourcart canyon head (western Mediterranean)

    Science.gov (United States)

    Mauffrey, Marie-Aline; Berné, Serge; Gaudin, Matthieu; Jouet, Gwenael

    2013-04-01

    Deeply incised canyons have been described in the Gulf of Lions since the end of the 19th century. Recently, the role of axial incision, as a pathway of high-density flows initiated within streams and cutting across the main thalweg of canyons, has been proposed as a mechanism for canyon evolution, in this area and elsewhere (Baztan et al., 2005). In this study, we used a large data base of very-high resolution seismic profiles in order to determine the precise architecture of the Bourcart (Aude) canyon head. The accurate 3D geometry of the buried and recent incisions through the Bourcart canyon head allows us to draw the pattern of canyon connections with shelf incised valleys. Furthermore, time constraints (and relation with sea-level changes) were obtained through the correlation with the Promess 1 drill site situated in the vicinity of the Bourcart canyon, and with long piston cores retrieved on the continental shelf in the same area. Our results demonstrate the direct connection of fluvial system(s) to present (and buried) axial incisions, and show the progressive evolution of seismic facies from typical "valley-fill" to typical "confined channel-levee" systems. Streams from the East (possibly the Rhone), then from the West (possibly the Agly) of the Gulf of Lions successively fed the canyon head. An important phase of deposition occurred within the canyon head at the onset of sea-level rise, probably in relation with increased water and sediment flux from the Pyrenees during the early Deglacial period. We hypothesize that, during this period, Pyrenean streams seasonally experienced very high-concentration sediment loads, capable of generating high density (probably hyperpycnal) flows in the canyon head. Only such high-concentration flows may explain the meandering pattern of axial incisions observed at very shallow depths, within the canyon head. Reference: Baztan, J. et al., 2005, Marine and Petroleum Geology, 22, 805-826

  4. Notch-signalling is required for head regeneration and tentacle patterning in Hydra.

    Science.gov (United States)

    Münder, Sandra; Tischer, Susanne; Grundhuber, Maresa; Büchels, Nathalie; Bruckmeier, Nadine; Eckert, Stefanie; Seefeldt, Carolin A; Prexl, Andrea; Käsbauer, Tina; Böttger, Angelika

    2013-11-01

    Local self-activation and long ranging inhibition provide a mechanism for setting up organising regions as signalling centres for the development of structures in the surrounding tissue. The adult hydra hypostome functions as head organiser. After hydra head removal it is newly formed and complete heads can be regenerated. The molecular components of this organising region involve Wnt-signalling and β-catenin. However, it is not known how correct patterning of hypostome and tentacles are achieved in the hydra head and whether other signals in addition to HyWnt3 are needed for re-establishing the new organiser after head removal. Here we show that Notch-signalling is required for re-establishing the organiser during regeneration and that this is due to its role in restricting tentacle activation. Blocking Notch-signalling leads to the formation of irregular head structures characterised by excess tentacle tissue and aberrant expression of genes that mark the tentacle boundaries. This indicates a role for Notch-signalling in defining the tentacle pattern in the hydra head. Moreover, lateral inhibition by HvNotch and its target HyHes are required for head regeneration and without this the formation of the β-catenin/Wnt dependent head organiser is impaired. Work on prebilaterian model organisms has shown that the Wnt-pathway is important for setting up signalling centres for axial patterning in early multicellular animals. Our data suggest that the integration of Wnt-signalling with Notch-Delta activity was also involved in the evolution of defined body plans in animals. © 2013 Elsevier Inc. All rights reserved.

  5. Research on a novel axial-flux magnetic-field-modulated brushless double-rotor machine with low axial force and high efficiency

    Directory of Open Access Journals (Sweden)

    Chengde Tong

    2017-05-01

    Full Text Available The axial-flux magnetic-field-modulated brushless double-rotor machine (MFM-BDRM is a possible alternative as a power-split device for hybrid electric vehicles (HEVs. However, the existence of large axial force may lead to assembly problems and rich inner air-gap harmonics could result in high PM loss and low efficiency. This paper proposes a novel axial-flux MFM-BDRM with improved PM rotor structure. 2-D analytical method to predict the magnetic-field distribution of the proposed MFM-BDRM is developed and the design procedure of the proposed machine is illustrated. The impact of key geometrical parameters on axial force and torque is investigated. To evaluate the advantage of the proposed machine, a comparison is made with a conventional one with respect to electromagnetic performances. Results show that the proposed machine is effective in reducing PM eddy loss and axial force by 60% and 35%, respectively.

  6. Research on a novel axial-flux magnetic-field-modulated brushless double-rotor machine with low axial force and high efficiency

    Science.gov (United States)

    Tong, Chengde; Song, Zhiyi; Bai, Jingang; Liu, Jiaqi; Zheng, Ping

    2017-05-01

    The axial-flux magnetic-field-modulated brushless double-rotor machine (MFM-BDRM) is a possible alternative as a power-split device for hybrid electric vehicles (HEVs). However, the existence of large axial force may lead to assembly problems and rich inner air-gap harmonics could result in high PM loss and low efficiency. This paper proposes a novel axial-flux MFM-BDRM with improved PM rotor structure. 2-D analytical method to predict the magnetic-field distribution of the proposed MFM-BDRM is developed and the design procedure of the proposed machine is illustrated. The impact of key geometrical parameters on axial force and torque is investigated. To evaluate the advantage of the proposed machine, a comparison is made with a conventional one with respect to electromagnetic performances. Results show that the proposed machine is effective in reducing PM eddy loss and axial force by 60% and 35%, respectively.

  7. Ultra-low-head hydroelectric technology: A review

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Daqing; Deng, Zhiqun (Daniel)

    2017-10-01

    In recent years, distributed renewable energy-generation technologies, such as wind and solar, have developed rapidly. Nevertheless, the utilization of ultra-low-head (ULH) water energy (i.e., situations where the hydraulic head is less than 3 m or the water flow is more than 0.5 m/s with zero head) has received little attention. We believe that, through technological innovations and cost reductions, ULH hydropower has the potential to become an attractive, renewable, and sustainable resource. This paper investigates potential sites for ULH energy resources, the selection of relevant turbines and generators, simplification of civil works, and project costs. This review introduces the current achievements on ULH hydroelectric technology to stimulate discussions and participation of stakeholders to develop related technologies for further expanding its utilization as an important form of renewable energy.

  8. Retroclival collections associated with abusive head trauma in children

    Energy Technology Data Exchange (ETDEWEB)

    Silvera, V.M.; Danehy, Amy R.; Carducci, Chiara; Grant, P.E.; Kleinman, Paul K. [Harvard Medical School, Department of Radiology, Boston Children' s Hospital, Boston, MA (United States); Newton, Alice W. [Harvard Medical School, Child Protection Program, Department of Pediatrics, Massachusetts General Hospital, Boston, MA (United States); Stamoulis, Catherine [Harvard Medical School, Department of Radiology, Boston Children' s Hospital, Boston, MA (United States); Harvard Medical School, Department of Neurology, Boston Children' s Hospital, Boston, MA (United States); Wilson, Celeste R. [Harvard Medical School, Division of General Pediatrics, Department of Medicine, Boston Children' s Hospital, Boston, MA (United States)

    2014-12-15

    Retroclival collections are rare lesions reported almost exclusively in children and strongly associated with trauma. We examine the incidence and imaging characteristics of retroclival collections in young children with abusive head trauma. We conducted a database search to identify children with abusive head trauma ≤3 years of age with brain imaging performed between 2007 and 2013. Clinical data and brain images of 65 children were analyzed. Retroclival collections were identified in 21 of 65 (32%) children. Ten (48%) were subdural, 3 (14%) epidural, 2 (10%) both, and 6 (28%) indeterminate. Only 8 of 21 retroclival collections were identifiable on CT and most were low or intermediate in attenuation. Eighteen of 21 retroclival collections were identifiable on MRI: 3 followed cerebral spinal fluid in signal intensity and 15 were bloody/proteinaceous. Additionally, 2 retroclival collections demonstrated a fluid-fluid level and 2 enhanced in the 5 children who received contrast material. Sagittal T1-weighted images, sagittal fluid-sensitive sequences, and axial FLAIR (fluid-attenuated inversion recovery) images showed the retroclival collections best. Retroclival collections were significantly correlated with supratentorial and posterior fossa subdural hematomas and were not statistically correlated with skull fracture or parenchymal brain injury. Retroclival collections, previously considered rare lesions strongly associated with accidental injury, were commonly identified in this cohort of children with abusive head trauma, suggesting that retroclival collections are an important component of the imaging spectrum in abusive head trauma. Retroclival collections were better demonstrated on MRI than CT, were commonly identified in conjunction with intracranial subdural hematomas, and were not significantly correlated with the severity of brain injury or with skull fractures. (orig.)

  9. Spinal cord injury and its association with blunt head trauma

    Directory of Open Access Journals (Sweden)

    Paiva WS

    2011-09-01

    Full Text Available Wellingson S Paiva, Arthur MP Oliveira, Almir F Andrade, Robson LO Amorim, Leonardo JO Lourenço, Manoel J TeixeiraDivision of Neurosurgery, University of São Paulo, BrazilBackground: Severe and moderate head injury can cause misdiagnosis of a spinal cord injury, leading to devastating long-term consequences. The objective of this study is to identify risk factors involving spine trauma and moderate-to-severe brain injury.Methods: A prospective study involving 1617 patients admitted in the emergency unit was carried out. Of these patients, 180 with moderate or severe head injury were enrolled. All patients were submitted to three-view spine series X-ray and thin cut axial CT scans for spine trauma investigations.Results: 112 male patients and 78 female patients, whose ages ranged from 11 to 76 years (mean age, 34 years. The most common causes of brain trauma were pedestrians struck by motor vehicles (31.1%, car crashes (27.7%, and falls (25%. Systemic lesions were present in 80 (44.4% patients and the most common were fractures, and lung and spleen injuries. 52.8% had severe and 47.2% moderate head trauma. Fourteen patients (7.8% suffered spinal cord injury (12 in cervical spine, one in lumbar, and one thoracic spine. In elderly patients, the presence of associated lesions and Glasgow Coma Scale (GCS < 9 were statistically significant as risk factors (P < 0.05 for spine injury.Conclusion: Spinal cord injury related to moderate and severe brain trauma usually affects the cervical spine. The incidence of spinal lesions and GCS < 9 points were related to greater incidence of spinal cord injury.Keywords: head injury, spine trauma, risk factors

  10. Landslides at Beachy Head, Sussex

    OpenAIRE

    Pennington, Catherine

    2007-01-01

    Beachy Head (Figures 1 and 2) is a famous natural and historic site and tourist attraction on the south coast. The cliff top area is part of the Downland Country Park managed by Eastbourne District Council. The section of cliff surveyed at Beachy Head is situated to the east of the modern lighthouse. The survey spans a 400 m south-facing stretch of beach with a cliff height of between 120 and 160 m. Cliffs and lighthouse at Beachy Head As part of a programme of work monitoring coast...

  11. Return of the talking heads

    DEFF Research Database (Denmark)

    Reinecke Hansen, Kenneth; Bro, Peter; Andersson, Ralf

    2016-01-01

    . In order to analyze the latest development entering the third wave, we propose a theoretically based dramaturgical model for the television news item. The analysis concludes that, with the current ‘return’ of the talking heads format, the pre-produced and pre-packaged bulletin program about past events......The present article suggests that the brief history of Western television news dramaturgy can be expounded as three major waves: from the early days of the talking heads in the studio, over the narrativization of the field report to a (re-)current studio- and field-based talking heads format...

  12. MR findings associated with positive distraction of the hip joint achieved by axial traction

    Energy Technology Data Exchange (ETDEWEB)

    Suter, Aline; Dietrich, Tobias J.; Maier, Matthias; Pfirrmann, Christian W.A. [Radiology, Orthopedic University Hospital Balgrist, Zurich (Switzerland); University of Zurich, Faculty of Medicine, Zurich (Switzerland); Dora, Claudio [Orthopedic University Hospital Balgrist, Orthopedic Surgery, Zurich (Switzerland); University of Zurich, Faculty of Medicine, Zurich (Switzerland)

    2015-06-01

    To determine which MR-arthrography findings are associated with positive hip joint distraction. One hundred patients with MR arthrography of the hip using axial traction were included. Traction was applied during the MR examination with an 8 kg (females) or 10 kg (males) water bag, attached to the ankle over a deflection pulley. Fifty patients showing joint space distraction were compared to an age- and gender-matched control group of 50 patients that did not show a joint distraction under axial traction. Two radiologists assessed the neck-shaft angle, lateral and anterior center-edge (CE) angles, CE angles in the transverse plane, extrusion index of the femoral head, acetabular depth, alpha angle, acetabular version, ligamentum teres, joint capsule and ligaments, iliopsoas tendon and the labrum. Mean joint space distraction in the study group was 0.9 ± 0.6 mm. Patients with positive joint space distraction had significantly higher neck-shaft angles (control group 131.6 ± 5.4 /study group 134.1 ± 6.1 , p < 0.05), smaller lateral CE angles (38.1 ± 5.9 /34.6 ± 7.2 , p < 0.05), smaller overall transverse CE angles (161.4 ± 9.9 /153.6 ± 9.6 , p < 0.001), smaller acetabular depth (4.1 ± 2.4 mm/5.8 ± 2.5 mm, p < 0.01), higher alpha angles (53.5 ± 7.8 /59.2 ± 10.1 , p < 0.01) and a thicker ligamentum teres (4.7 ± 1.4 mm/5.4 ± 1.8 mm, p < 0.05). The other parameters revealed no significant differences. ICC values for interobserver agreement were 0.71-0.95 and kappa values 0.43-0.92. Increased neck-shaft angles, small CE angles, small acetabular depth, higher alpha angles and a thick ligamentum teres are associated with positive joint distraction. (orig.)

  13. MR findings associated with positive distraction of the hip joint achieved by axial traction.

    Science.gov (United States)

    Suter, Aline; Dietrich, Tobias J; Maier, Matthias; Dora, Claudio; Pfirrmann, Christian W A

    2015-06-01

    To determine which MR-arthrography findings are associated with positive hip joint distraction. One hundred patients with MR arthrography of the hip using axial traction were included. Traction was applied during the MR examination with an 8 kg (females) or 10 kg (males) water bag, attached to the ankle over a deflection pulley. Fifty patients showing joint space distraction were compared to an age- and gender-matched control group of 50 patients that did not show a joint distraction under axial traction. Two radiologists assessed the neck-shaft angle, lateral and anterior center-edge (CE) angles, CE angles in the transverse plane, extrusion index of the femoral head, acetabular depth, alpha angle, acetabular version, ligamentum teres, joint capsule and ligaments, iliopsoas tendon and the labrum. Mean joint space distraction in the study group was 0.9 ± 0.6 mm. Patients with positive joint space distraction had significantly higher neck-shaft angles (control group 131.6 ± 5.4°/study group 134.1 ± 6.1°, p < 0.05), smaller lateral CE angles (38.1 ± 5.9°/34.6 ± 7.2°, p < 0.05), smaller overall transverse CE angles (161.4 ± 9.9°/153.6 ± 9.6°, p < 0.001), smaller acetabular depth (4.1 ± 2.4 mm/5.8 ± 2.5 mm, p < 0.01), higher alpha angles (53.5 ± 7.8°/59.2 ± 10.1°, p < 0.01) and a thicker ligamentum teres (4.7 ± 1.4 mm/5.4 ± 1.8 mm, p < 0.05). The other parameters revealed no significant differences. ICC values for interobserver agreement were 0.71-0.95 and kappa values 0.43-0.92. Increased neck-shaft angles, small CE angles, small acetabular depth, higher alpha angles and a thick ligamentum teres are associated with positive joint distraction.

  14. Diagnostic scope of computer tomography in hip disease - Paget's disease, femoral head necrosis, coxarthrosis, coxarthritis

    Energy Technology Data Exchange (ETDEWEB)

    Nebel, G.; Lingg, G.; Reid, W.

    1982-10-01

    The value of computer tomography was investigated in Paget's disease of the hip, femoral head necrosis (adult avascular and osteoradionecrosis), coxarthrosis and coxarthritis (bacterial and rheumatoid). The greatest value of CT is in the diagnosis of adult avascular necrosis of the femoral head and is valuable for localising the necrotic area in the axial plane. This is of value in planning surgical treatment (displacement osteotomy or endoprosthesis). In Paget's disease, coxarthrosis and coxarthritis, CT provides only additional or more precise information.

  15. The effects of initial rise and axial loads on MEMS arches

    KAUST Repository

    Tella, Sherif Adekunle

    2017-04-07

    Arch microbeams have been utilized and proposed for many uses over the past few years due to their large tunability and bistability. However, recent experimental data have shown different mechanical behavior of arches when subjected to axial loads. This paper aims to investigate in depth the influence of the competing effects of initial rise and axial loads on the mechanical behavior of micromachined arches; mainly their static deflection and resonant frequencies. Based on analytical solutions, the static response and eigenvalue problems are analyzed for various values of initial rises and axial loads. Universal curves showing the variation of the first three resonance frequencies of the arch are generated for various values of initial rise under both tensile and compressive axial loads. This study shows that increasing the tensile or compressive axial loads for different values of initial rise may lead to either increase in the stiffness of the beam or initial decrease in the stiffness, which later increases as the axial load is increased depending on the dominant effect of the initial rise of the arch and the axial load. The obtained universal curves represent useful design tools to predict the tunability of arches under axial loads for various values of initial rises. The use of the universal curves is demonstrated with an experimental case study. Analytical formulation is developed to predict the point of minimum where the trend of the resonance frequency versus axial loads changes qualitatively due to the competing effects of axial loads and initial curvature.

  16. Axial length of atomic bomb survivors in Nagasaki

    Energy Technology Data Exchange (ETDEWEB)

    Wakiyama, Harumi; Kishikawa, Yasuhiro; Imamura, Naoki [Nagasaki Atomic Bomb Hospital (Japan); Amemiya, Tsugio [Nagasaki Univ. (Japan). School of Medicine

    2002-03-01

    We reviewed a series of 778 patients who had cataract surgery during the past 4 years at the Nagasaki Atomic Bomb Memorial Hospital. We evaluated the history of exposure to radiation by atomic bomb in 1945, axial length and state of refraction. All were born before 1945. The series comprised 263 males and 515 females. Their ages averaged 76.5{+-}8.6 years. History of exposure to radiation was present in 356 patients. The remaining 422 patients served as control. There was no difference in the type of cataract between the two groups. High myopia was present in 11 irradiated patients (3.2%) and in 24 patients in the control group (6.0%). The difference was not significant (p=0.083). There was no high myopia among 24 patients who were aged 18 years or less at the time of radiation and who were within 2 km from the epicenter. No difference was present regarding the axial length between the two groups or between both sexes. The present result is not definitive because ''irradiated group'' would include those with little or no exposure and because precise data has not been available about the dosis of radiation. (author)

  17. Characteristics of the Swirling Flow Generated by an Axial Swirler

    Science.gov (United States)

    Fu, Yongqiang; Jeng, San-Mou; Tacina, Robert

    2005-01-01

    An experimental investigation was conducted to study the aerodynamic characteristics of the confined, non-reacting, swirling flow field. The flow was generated by a helicoidal axial-vaned swirler with a short internal convergent-divergent venturi, which was confined within 2-inch square test section. A series of helicoidal axial-vaned swirlers have been designed with tip vane angles of 40 deg., 45 deg., 50 deg., 55 deg., 60 deg. and 65 deg.. The swirler with the tip vane angle of 60 deg. was combined with several simulated fuel nozzle insertions of varying lengths. A two-component Laser Doppler Velocimetry (LDV) system was employed to measure the three-component mean velocities and Reynolds stresses. Detailed data are provided to enhance understanding swirling flow with different swirl degrees and geometries and to support the development of more accurate physicaVnumerica1 models. The data indicated that the degree of swirl had a clear impact on the mean and turbulent flow fields. The swirling flow fields changed significantly with the addition of a variety of simulated fuel nozzle insertion lengths

  18. Axial Instability Growth in Tungsten Wire Array Z-Pinches

    Science.gov (United States)

    Cahill, Adam; Knapp, Patrick; Greenly, John; Pikuz, Sergei; Shelkovenko, Tania; Hammer, David

    2010-11-01

    The individual exploding wires in wire array z-pinches have been shown to suffer from axially non-uniformity beginning from the moment of plasma formation. This non-uniformity grows in amplitude and wavelength until it reaches what appears to be a material dependent wavelength at the time array implosion begins. Previous work by Knapp et al. [1] studied the temporal evolution of this instability in aluminum wire arrays. We have extended that work to include the evolution of tungsten wire array instabilities. Time gated laser shadowgraphy is used to track wavelength and amplitude over a series of shots to develop a record of the instability's growth. We attempt to identify array parameters which significantly contribute to the growth of this instability. [4pt] [1] Knapp, P. F., J. B. Greenly, P. A. Gourdain, C. L. Hoyt, M. R. Martin, S. A. Pikuz, C. E. Seyler, T. A. Shelkovenko, and D. A. Hammer. ``Growth and Saturation of the Axial Instability in Low Wire Number Wire Array Z Pinches.'' Physics of Plasmas 17 (2010). Web.

  19. Pit above the lesser tuberosity in axial view radiography.

    Science.gov (United States)

    Cho, Jae-Ho; Han, Kyeong-Jin; Lee, Doo-Hyung; Chung, Nam-Su; Park, Do Young

    2015-02-01

    This study examined the relationship between the presence of a pit above the lesser tuberosity on axial view radiographs and rotator cuff tears and compared the demographic data between groups according to the presence of a pit above the lesser tuberosity. The hypothesis of this study was that the radiographic finding of a pit above the lesser tuberosity is related to rotator cuff tears. For 112 patients with a symptomatic rotator cuff tear, plain radiographs of the symptomatic shoulder (tear side radiographs) and plain radiographs of the asymptomatic contralateral shoulder (no-tear side radiographs) were assessed. Seventeen radiological findings, including a pit above the lesser tuberosity, osteophytes, subchondral cysts, and sclerosis, were recorded by one blinded observer. Demographic data such as age, duration of symptoms, sex, arm dominance, smoking history, trauma history, American Shoulder and Elbow Surgeons score, Constant score, and involved tendon were collected. A pit above the lesser tuberosity was noted on tear side radiographs of 40 patients (35.7 %) and on the no-tear side radiographs of 27 patients (24.1 %), representing a significant difference (P = 0.040). A pit associated with a rotator cuff tear was observed more often in the dominant arm (P = 0.040) and more often in patients with less previous trauma (P = 0.024). A pit above the lesser tuberosity on axial view radiography was associated with a rotator cuff tear and occurred more often in the dominant arm of patients who had no trauma history. Prognostic study, Level III.

  20. Axial Ge/Si nanowire heterostructure tunnel FETs.

    Energy Technology Data Exchange (ETDEWEB)

    Dayeh, Shadi A. (Los Alamos National Laboratory); Gin, Aaron V.; Huang, Jian Yu; Picraux, Samuel Thomas (Los Alamos National Laboratory)

    2010-03-01

    Axial Ge/Si heterostructure nanowires (NWs) allow energy band-edge engineering along the axis of the NW, which is the charge transport direction, and the realization of asymmetric devices for novel device architectures. This work reports on two significant advances in the area of heterostructure NWs and tunnel FETs: (i) the realization of 100% compositionally modulated Si/Ge axial heterostructure NWs with lengths suitable for device fabrication and (ii) the design and implementation of Schottky barrier tunnel FETs on these NWs for high-on currents and suppressed ambipolar behavior. Initial prototype devices with 10 nm PECVD SiN{sub x} gate dielectric resulted in a very high current drive in excess of 100 {micro}A/{micro}m (I/{pi}D) and 10{sup 5} I{sub on}/I{sub off} ratios. Prior work on the synthesis of Ge/Si axial NW heterostructures through the VLS mechanism have resulted in axial Si/Si{sub 1-x}Ge{sub x} NW heterostructures with x{sub max} {approx} 0.3, and more recently 100% composition modulation was achieved with a solid growth catalyst. In this latter case, the thickness of the heterostructure cannot exceed few atomic layers due to the slow axial growth rate and concurrent radial deposition on the NW sidewalls leading to a mixture of axial and radial deposition, which imposes a big challenge for fabricating useful devices form these NWs in the near future. Here, we report the VLS growth of 100% doping and composition modulated axial Ge/Si heterostructure NWs with lengths appropriate for device fabrication by devising a growth procedure that eliminates Au diffusion on the NW sidewalls and minimizes random kinking in the heterostructure NWs as deduced from detailed microscopy analysis. Fig. 1 a shows a cross-sectional SEM image of epitaxial Ge/Si axial NW heterostructures grown on a Ge(111) surface. The interface abruptness in these Ge/Si heterostructure NWs is of the order of the NW diameter. Some of these NWs develop a crystallographic kink that is {approx

  1. Counting heads in Cairo.

    Science.gov (United States)

    1994-09-14

    Representatives of 182 nations gathered in Cairo in September, 1994, at the Un Conference on Population and Development. The resulting 113-page Draft Program of Action contains sober discussions on demographic issues, including projections of population increase in the decades ahead. It focuses on the potential growth of famine, disease, warfare, environmental degradation, and general human misery if the world's population cannot be stabilized at around 8 billion in the next 20 years. The 1994 figure stands at about 5.7 billion, and there will be 12.5 billion people if no action is taken. Previous conferences hosted under the UN helped spark a remarkable decline in fertility rates, especially in Indonesia and Thailand. Even in populous Bangladesh, some 40% of women now use contraceptives, while the fertility rate has dropped from 7 to 4.2 in 2 decades. The proposals debated in Cairo include sustainable development, gender equality, and the empowerment of women. Whatever the country or culture, fertility rates tend to fall dramatically as women become more educated. This has been borne out almost everywhere, most notably in Japan and Singapore. The conference has been criticized by the Vatican as advocating an international standard for easy abortion, encouraging sex education for teenagers, and sanctioning marriages other than between a man and a woman. Some conservative Muslim thinkers have also complained that it promotes Western values and fosters illicit sex. Many supporters of population planning have argued that the empowerment of women will reduce the incidence of abortion. The Cairo document will alienate many across Asia with its references to the plurality of family forms, including the large number of households headed by single parents. The one goal on which everyone can agree is the need to promote policies that will stabilize the global headcount.

  2. [Total prosthesis arthroplasty in femur head necrosis].

    Science.gov (United States)

    Elke, R; Morscher, E

    1990-08-01

    In young patients with advanced necrosis of the femoral head, the short- and medium-term results of total prosthesis arthroplasty are the most satisfactory. However, the prospect of aseptic loosening hangs over such arthroplasties like Damocles' sword. Reports from the literature suggest that, in addition to the age of the patient, there is also an endogenous factor that can be responsible not only for the etiology and pathogenesis of the necrosis, but also for the early loosening of the prosthesis. We have followed up 54 patients (73 hip joints) who had total hip replacement as a result of necrosis of the femoral head between 1976 and 1988. Altogether, 3 acetabular and 5 femoral shafts had to be replaced (7 patients). This corresponds to a loosening rate of 10% after an average of 4.9 years. Hence, the prosthesis changing rate is lower than that reported by other authors, but is still higher than in patients with coxarthrosis. Only 2 of 52 cemented shaft prostheses had to be replaced; the average age of these patients was 61.4 years. Of the 21 cement-free shaft implantations, 3 had to be replaced, the average age of these patients being 42.9 years. The fact that the average age of the latter patients was lower may be the reason for the revision rate not being significantly higher for the non-cemented shafts. In view of the fact that necrosis of the femoral head can rapidly result in the patient becoming an invalid if it is allowed to follow its natural course, hip joint prostheses should also be offered to younger patients.

  3. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... digital cloud server. Currently, MRI is the most sensitive imaging test of the head (particularly the brain) ... Society of Urogenital Radiology note that the available data suggest that it is safe to continue breastfeeding ...

  4. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... medically necessary. MRI may not always distinguish between cancer tissue and fluid, known as edema . MRI typically ... Brain Tumors Radiation Therapy for Head and Neck Cancer Others : American Stroke Association National Stroke Association top ...

  5. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... a computer to produce detailed pictures of the brain and other cranial structures that are clearer and ... sensitive imaging test of the head (particularly the brain) in routine clinical practice. top of page What ...

  6. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... of the head (particularly the brain) in routine clinical practice. top of page What are some common ... acutely injured; however, this decision is based on clinical judgment. This is because traction devices and many ...

  7. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... MRI scanners are air-conditioned and well-lit. Music may be played through the headphones to help ... page Additional Information and Resources RTAnswers.org : Radiation Therapy for Brain Tumors Radiation Therapy for Head and ...

  8. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... an IV line, into a vein in your hand or arm. A saline solution may be used ... Tumor Treatment Magnetic Resonance Imaging (MRI) Safety Alzheimer's Disease Head Injury Brain Tumors Images related to Magnetic ...

  9. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... Videos About Us News Physician Resources Professions Site Index A-Z Magnetic Resonance Imaging (MRI) - Head Magnetic ... very early stage by mapping the motion of water molecules in the tissue. This water motion, known ...

  10. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... practice. top of page What are some common uses of the procedure? MR imaging of the head ... gadolinium contrast, it may still be possible to use it after appropriate pre-medication. Patient consent will ...

  11. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... MRI) of the head uses a powerful magnetic field, radio waves and a computer to produce detailed ... there’s a possibility you are pregnant. The magnetic field is not harmful, but it may cause some ...

  12. Head, Neck, and Oral Cancer

    Science.gov (United States)

    ... cancer of the head, neck and mouth. The Oral Cancer Foundation estimates that close to 42,000 Americans ... diagnosed with oral or pharyngeal cancer this year. Oral cancer’s mortality is particularly high, not because it is ...

  13. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... have a personal story about radiology? Share your patient story here Images ... (fMRI) - Brain Head and Neck Cancer Treatment Brain Tumor Treatment Magnetic Resonance Imaging (MRI) ...

  14. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... is not harmful, but it may cause some medical devices to malfunction. Most orthopedic implants pose no ... Head? Magnetic resonance imaging (MRI) is a noninvasive medical test that physicians use to diagnose medical conditions. ...

  15. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... the same effect. A very irregular heartbeat may affect the quality of images obtained using techniques that ... Tumor Treatment Magnetic Resonance Imaging (MRI) Safety Alzheimer's Disease Head Injury Brain Tumors Images related to Magnetic ...

  16. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... test of the head (particularly the brain) in routine clinical practice. top of page What are some ... told otherwise, you may follow your regular daily routine and take food and medications as usual. Some ...

  17. Eye-based head gestures

    DEFF Research Database (Denmark)

    Mardanbegi, Diako; Witzner Hansen, Dan; Pederson, Thomas

    2012-01-01

    A novel method for video-based head gesture recognition using eye information by an eye tracker has been proposed. The method uses a combination of gaze and eye movement to infer head gestures. Compared to other gesture-based methods a major advantage of the method is that the user keeps the gaze...... on the interaction object while interacting. This method has been implemented on a head-mounted eye tracker for detecting a set of predefined head gestures. The accuracy of the gesture classifier is evaluated and verified for gaze-based interaction in applications intended for both large public displays and small...... mobile phone screens. The user study shows that the method detects a set of defined gestures reliably....

  18. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... the same effect. A very irregular heartbeat may affect the quality of images obtained using techniques that ... Information and Resources RTAnswers.org : Radiation Therapy for Brain Tumors Radiation Therapy for Head and Neck Cancer ...

  19. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... a CD or uploaded to a digital cloud server. Currently, MRI is the most sensitive imaging test ... Brain Tumor Treatment Magnetic Resonance Imaging (MRI) Safety Alzheimer's Disease Head Injury Brain Tumors Images related to Magnetic ...

  20. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... the same effect. A very irregular heartbeat may affect the quality of images obtained using techniques that ... Brain Tumor Treatment Magnetic Resonance Imaging (MRI) Safety Alzheimer's Disease Head Injury Brain Tumors Images related to ...

  1. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... Radiation Therapy for Head and Neck Cancer Others : American Stroke Association National Stroke Association top of page ... and is further reviewed by committees from the American College of Radiology (ACR) and the Radiological Society ...

  2. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... the head uses a powerful magnetic field, radio waves and a computer to produce detailed pictures of ... the body being imaged, send and receive radio waves, producing signals that are detected by the coils. ...

  3. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... data suggest that it is safe to continue breastfeeding after receiving intravenous contrast. For further information please ... Magnetic Resonance Imaging (MRI) Safety Alzheimer's Disease Head Injury Brain Tumors Images related to Magnetic Resonance Imaging ( ...

  4. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... scanner. top of page How does the procedure work? Unlike conventional x-ray examinations and computed tomography ( ... for Head and Neck Cancer Others : American Stroke Association National Stroke Association top of page This page ...

  5. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... copied to a CD or uploaded to a digital cloud server. Currently, MRI is the most sensitive ... Brain Tumor Treatment Magnetic Resonance Imaging (MRI) Safety Alzheimer's Disease Head Injury Brain Tumors Images related to Magnetic ...

  6. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... of the head uses a powerful magnetic field, radio waves and a computer to produce detailed pictures ... medical conditions. MRI uses a powerful magnetic field, radio frequency pulses and a computer to produce detailed ...

  7. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... or headphones during the exam. MRI scanners are air-conditioned and well-lit. Music may be played ... the limitations of MRI of the Head? High-quality images are assured only if you are able ...

  8. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... may sense a temporary metallic taste in their mouth after the contrast injection. If you do not ... Magnetic Resonance Imaging (MRI) Safety Alzheimer's Disease Head Injury Brain Tumors Images related to Magnetic Resonance Imaging ( ...

  9. Magnetic Resonance Imaging (MRI) -- Head

    Medline Plus

    Full Text Available ... and may add approximately 15 minutes to the total exam time. top of page What will I ... the limitations of MRI of the Head? High-quality images are assured only if you are able ...

  10. Head and Neck Cancer Pain.

    Science.gov (United States)

    Ing, Jakun W

    2017-08-01

    Pain is a significant morbidity resulting from head and neck cancer. Pain may also be the result of the treatments directed against head and neck cancer. An experienced practitioner may manage this pain by understanding the multifactorial mechanisms of pain and the various pharmacotherapies available. Pain should be managed with multiple medications in a multimodal approach, and nonpharmacologic therapies should be considered as well. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Henry Head and the Theatre of Reverie

    Directory of Open Access Journals (Sweden)

    Tiffany Watt-Smith

    2011-04-01

    Full Text Available In 1903, the neurologist Henry Head (1861-1940 embarked on a painful self-experiment, in which he severed the radial nerve of his left arm, and then charted the gradual and faltering return of sensitivity to the limb over the next four and a half years. To directly experience his own sensations, Head entered into a trance-like state of distraction or reverie he called a ‘negative attitude of attention’. This article explores Head’s peculiar technique for looking within, and argues that while introspection was an established strategy in psychological laboratories, Head’s reverie also resonated with techniques associated with actors and theatrical audiences during this period. Viewing psychological self-experimentation through the lens of theatre, this article makes visible aspects of Head’s embodied, affective laboratory encounters, often obscured in accounts of his experiment. At the same time, it proposes that the broader historical and cultural significance of Head’s experiment lies in his attempt to observe himself by producing states of inattention and reverie at will, mental ‘attitudes’ that were themselves the subject of a rapidly evolving debate in scientific and aesthetic circles at the turn of the twentieth century.

  12. Interconnection between several eye biomechanical and biometric parameters in children with axial and refractive mild myopia

    Directory of Open Access Journals (Sweden)

    T. Ye. Tsybulskaya

    2016-08-01

    Full Text Available Aim – to study the relationship of biometric and biomechanical indicators of corneoscleral capsule of the eye in children with axial and refractive mild myopia. Materials and methods. Axial myopia was diagnosed in 32 children (64 eyes, refractive myopia – 18 (36 eyes. The control group – 16 children without ophthalmic diseases (32 eyes. Eye examination: visometry, automated refractometry, biomicroscopy, ophthalmoscopy, determination of the axial length of the eyeball and corneal hysteresis. Results. Significant differences were determined in the indicators of dioptric power of the cornea: 42.2 dpt in patients with axial and 44.7 dpt with refractive myopia (p<0.05, and also difference between patients with refractive myopia and the control group, in which the diopter power of cornea was 42.6 (p<0.05. There are also significant differences in the indicators of the axial length of eyes between axial and refractive myopia – 24.5±0.64 mm and 23.1±0.43 mm (p<0.05. Significant difference with the control group in the axial length marked only in eyes with axial myopia 22.7±0.33 mm and 24.5±0.64 mm, respectively (p<0.05. Corneal hysteresis determined significantly reduced on eyes with both the axial and refractive myopia, which was significantly lower than in the indicators of emmetropic eyes of the control group 13.7 (p<0.05. Corneal hysteresis is inversely related to the axial length of the eyeball: in patients with axial myopia r -0.32, p<0.05; with refractive myopia r -0.36, p<0.05. Сorrelation between diopter power of cornea and axial length of the eyeball: r -0.53, р<0.05 in eyes with axial myopia and r -0.42, p<0.05 refractive myopia. Comparative analysis showed no significant differences between the corneal hysteresis, the axial length of the eye and the spherical component of myopia. Conclusions. In patients with axial and refractive mild myopia corneal hysteresis is reduced on average in 1.2 and 1.1 times, in comparison with

  13. Cyclic Axial-Torsional Deformation Behavior of a Cobalt-Base Superalloy

    Science.gov (United States)

    Bonacuse, Peter J.; Kalluri, Sreeramesh

    1995-01-01

    The cyclic, high-temperature deformation behavior of a wrought cobalt-base super-alloy, Haynes 188, is investigated under combined axial and torsional loads. This is accomplished through the examination of hysteresis loops generated from a biaxial fatigue test program. A high-temperature axial, torsional, and combined axial-torsional fatigue database has been generated on Haynes 188 at 760 C. Cyclic loading tests have been conducted on uniform gage section tubular specimens in a servohydraulic axial-torsional test rig. Test control and data acquisition were accomplished with a minicomputer. The fatigue behavior of Haynes 188 at 760 C under axial, torsional, and combined axial-torsional loads and the monotonic and cyclic deformation behaviors under axial and torsional loads have been previously reported. In this paper, the cyclic hardening characteristics and typical hysteresis loops in the axial stress versus axial strain, shear stress ,versus engineering shear strain, axial strain versus engineering shear strain. and axial stress versus shear stress spaces are presented for cyclic in-phase and out-of-phase axial-torsional tests. For in-phase tests, three different values of the proportionality constant lambda (the ratio of engineering shear strain amplitude to axial strain amplitude, are examined, viz. 0.86, 1.73, and 3.46. In the out-of-phase tests, three different values of the phase angle, phi (between the axial and engineering shear strain waveforms), are studied, viz., 30, 60, and 90 degrees with lambda equals 1.73. The cyclic hardening behaviors of all the tests conducted on Haynes 188 at 760 C are evaluated using the von Mises equivalent stress-strain and the maximum shear stress-maximum engineering shear strain (Tresca) curves. Comparisons are also made between the hardening behaviors of cyclic axial, torsional, and combined in-phase (lambda = 1.73 and phi = 0) and out-of-phase (lambda = 1.73 and phi = 90') axial-torsional fatigue tests. These comparisons

  14. Axial design of fuel for BWRs using neural networks; Diseno axial de combustible para BWRs usando redes neuronales

    Energy Technology Data Exchange (ETDEWEB)

    Ortiz, J.J.; Castillo, A.; Montes, J.L.; Perusquia, R. [ININ, Carretera Mexico-Toluca s/n, 52750 La Marquesa, Ocoyoacac, Estado de Mexico (Mexico)]. e-mail: jjortiz@nuclear.inin.mx

    2007-07-01

    In this work a new system of axial optimization of fuel is presented based on a recurrent multi state neural net called RENODC. They are described with detail the main characteristics of this type of neural net (architecture, energy function and actualization of neural states) and like was adapted to the assemble design of nuclear fuel. The fuel design is proven by means of a fuel recharge and pre determined control rod patterns. By this way a good axial fuel design one has, when the thermal limits are fulfilled along the cycle, the reactor stays critic and at least the wanted longitude of the cycle is reached; also the margin of in cold turned off is verified. The assemble of fuel created with RENODC it is substituted by a recharge assemble and it is sought to verify that the energy requirements and aspects of safety are completed. The used cycle corresponds to a balance cycle of 18 months that it can be applied to the Laguna Verde Nucleo electric Central. The tests demonstrate the effectiveness of the system to reach satisfactory results in times of CPU of around 4 hours. This way, it could be proven that the design proposed with a lightly superior enrichment to that of the substituted design, fulfills the energy requirements. In later stages of this project this system will be coupled to the other optimization modules that are already had. (Author)

  15. Tilted versus axially placed dental implants: a meta-analysis.

    Science.gov (United States)

    Chrcanovic, Bruno Ramos; Albrektsson, Tomas; Wennerberg, Ann

    2015-02-01

    The purpose of the present review was to test the null hypothesis of no difference in the implant failure rate, marginal bone loss, and postoperative infection for patients being rehabilitated by tilted or by axially placed dental implants, against the alternative hypothesis of a difference. An electronic search without time or language restrictions was undertaken in July 2014. Eligibility criteria included clinical human studies, either randomised or not, interventional or observational. The estimates of an intervention were expressed in risk ratio (RR) and mean difference (MD) in millimetres. The search strategy resulted in 44 publications. A total of 5029 dental implants were tilted (82 failures; 1.63%), and 5732 implants were axially placed (104 failures; 1.81%). The difference between the procedures did not significantly affect the implant failure rates (P=0.40), with a RR of 1.14 (95% CI 0.84-1.56). A statistically significant difference was found for implant failures when studies evaluating implants inserted in maxillae only were pooled (RR 1.70, 95% CI 1.05-2.74; P=0.03), the same not happening for the mandible (RR 0.77, 95% CI 0.39-1.52; P=0.45). There were no apparent significant effects of tilted dental implants on the occurrence of marginal bone loss (MD 0.03, 95% CI -0.03 to 0.08; P=0.32). Due to lack of satisfactory information, meta-analysis for the outcome 'postoperative infection' was not performed. It is suggested that the differences in angulation of dental implants might not affect the implant survival or the marginal bone loss. The reliability and validity of the data collected and the potential for biases and confounding factors are some of the shortcomings of the present study. The question whether tilted implants are more at risk for failure than axially placed implants has received increasing attention in the last years. As the philosophies of treatment alter over time, a periodic review of the different concepts is necessary to refine

  16. Predictors of Persistent Axial Neck Pain After Cervical Laminoplasty.

    Science.gov (United States)

    Kimura, Atsushi; Shiraishi, Yasuyuki; Inoue, Hirokazu; Endo, Teruaki; Takeshita, Katsushi

    2017-06-06

    Retrospective analysis of prospective data OBJECTIVE.: The aim of this study was to reveal baseline predictors of persistent post-laminoplasty neck pain. Axial neck pain is one of the most common complications after cervical laminoplasty; however, baseline predictors of persistent post-laminoplasty neck pain are unclear. We analyzed data from 156 patients who completed a 2-year follow-up after double-door laminoplasty for degenerative cervical myelopathy (DCM). Patients rated the average intensity of axial neck pain in the last month using an 11-point numerical rating scale (NRS) preoperatively and at the 2-year follow-up. The dependent variable was the presence of moderate-to-severe neck pain (NRS ≥4) at the 2-year follow-up. The independent variables included patient characteristics, baseline radiological parameters, surgical variables, baseline axial neck pain intensity, and baseline functions, which were measured by the Japanese Orthopaedic Association (JOA) score and the Short Form-36 survey (SF-36). Logistic regression analysis was performed to identify independent predictors of moderate-to-severe neck pain after laminoplasty. At the 2-year follow-up, 51 patients (32%) had moderate-to-severe neck pain, and 106 patients (68%) had no or mild pain. Univariate analysis revealed that the ratio of cervical anterolisthesis, ratio of current smoking, baseline neck pain intensity, and baseline SF-36 mental component summary (MCS) differed significantly between the groups. Multivariate logistic regression analysis showed that independent predictors of moderate-to-severe neck pain at the 2-year follow-up include the presence of anterolisthesis, current smoking, moderate-to-severe baseline neck pain, and lower SF-36 MCS. The presence of anterolisthesis and moderate-to-severe baseline neck pain were also associated with significantly poorer physical function after surgery. The presence of anterolisthesis was associated not only with the highest odds ratio of persistent

  17. Spine and axial skeleton injuries in the National Football League.

    Science.gov (United States)

    Mall, Nathan A; Buchowski, Jacob; Zebala, Lukas; Brophy, Robert H; Wright, Rick W; Matava, Matthew J

    2012-08-01

    The majority of previous literature focusing on spinal injuries in American football players is centered around catastrophic injuries; however, this may underestimate the true number of these injuries in this athletic cohort. The goals of this study were to (1) report the incidence of spinal and axial skeleton injuries, both minor and severe, in the National Football League (NFL) over an 11-year period; (2) determine the incidence of spinal injury by injury type, anatomic location, player position, mechanism of injury, and type of exposure (practice vs game); and (3) determine the average number of practices and days missed because of injury for each injury type. Descriptive epidemiological study. All documented injuries to the cervical, thoracic, and lumbar spine; pelvis; ribs; and spinal cord were retrospectively analyzed using the NFL's injury surveillance database over a period of 11 seasons from 2000 through 2010. The data were analyzed by the number of injuries per athlete-exposure, the anatomic location and type of injury, player position, mechanism of injury, and number of days missed per injury. A total of 2208 injuries occurred to the spine or axial skeleton over an 11-season interval in the NFL, with a mean loss of 25.7 days per injury. This represented 7% of the total injuries during this time period. Of these 2208 injuries, 987 (44.7%) occurred in the cervical spine. Time missed from play was greatest for thoracic disc herniations (189 days/injury). Other injuries that had a mean time missed greater than 30 days included (in descending order) cervical fracture (120 days/injury), cervical disc degeneration/herniation (85 days/injury), spinal cord injury (77 days/injury), lumbar disc degeneration/herniation (52 days/injury), thoracic fracture (34 days/injury), and thoracic nerve injury (30 days/injury). Offensive linemen were the most likely to suffer a spinal injury, followed by defensive backs, defensive linemen, and linebackers. Blocking and tackling

  18. The influence of head and neck position on kinematics of the back in riding horses at the walk and trot.

    Science.gov (United States)

    Rhodin, M; Johnston, C; Holm, K Roethlisberger; Wennerstrand, J; Drevemo, S

    2005-01-01

    A common opinion among riders and in the literature is that the positioning of the head and neck influences the back of the horse, but this has not yet been measured objectively. To evaluate the effect of head and neck position on the kinematics of the back in riding horses. Eight Warmblood riding horses in regular work were studied on a treadmill at walk and trot with the head and neck in 3 different predetermined positions achieved by side reins attached to the bit and to an anticast roller. The 3-dimensional movement of the thoracolumbar spine was measured from the position of skin-fixed markers recorded by infrared videocameras. Head and neck position influenced the movements of the back, especially at the walk. When the head was fixed in a high position at the walk, the flexion-extension movement and lateral bending of the lumbar back, as well as the axial rotation, were significantly reduced when compared to movements with the head free or in a low position. At walk, head and neck position also significantly influenced stride length, which was shortest with the head in a high position. At trot, the stride length was independent of head position. Restricting and restraining the position and movement of the head and neck alters the movement of the back and stride characteristics. With the head and neck in a high position stride length and flexion and extension of the caudal back were significantly reduced. Use of side reins in training and rehabilitation programmes should be used with an understanding of the possible effects on the horse's back.

  19. Effect of flow oscillations on axial energy transport in a porous material

    Science.gov (United States)

    Siegel, R.

    1987-01-01

    The effects of flow oscillations on axial energy diffusion in a porous medium, in which the flow is continuously disrupted by the irregularities of the porous structure, are analyzed. The formulation employs an internal heat transfer coefficient that couples the fluid and solid temperatures. The final relationship shows that the axial energy transport per unit cross-sectional area and time is directly proportional to the axial temperature gradient and the square of the maximum fluid displacement.

  20. Sum rule analysis of vector and axial-vector spectral functions with excited states in vacuum

    OpenAIRE

    Hohler, Paul M.; Rapp, Ralf

    2012-01-01

    We simultaneously analyze vector and axial-vector spectral functions in vacuum using hadronic models constrained by experimental data and the requirement that Weinberg-type sum rules are satisfied. Upon explicit inclusion of an excited vector state, viz. rho', and the requirement that the perturbative continua are degenerate in vector and axial-vector channels, we deduce the existence of an excited axial-vector resonance state, a1', in order that the Weinberg sum rules are satisfied. The resu...

  1. Simulations of axial B-dot monitors inside a groove in the beam pipe

    Energy Technology Data Exchange (ETDEWEB)

    He, Xiaozhong, E-mail: hexiaozhong@tsinghua.org.cn [Institute of Fluid Physics, Chinese Academy of Engineering Physics, Mianyang, Sichuan (China); Pang, Jian; Li, Qin [Institute of Fluid Physics, Chinese Academy of Engineering Physics, Mianyang, Sichuan (China); Du, Yingchao [Department of Engineering Physics, Tsinghua University, Beijing (China)

    2013-11-21

    Beam tilt measurement is important for understanding the beam dynamics. Our previous theoretical studies and simulations have shown that the axial B-dot in smooth beam pipe can be used to measure the beam tilt directly. Practical azimuthal B-dot loops typically are placed inside a groove in the beam pipe to avoid direct beam interception. For the same purpose, practical axial B-dot loops should also be placed inside such a groove. In this paper, responses of axial magnetic field to the beam tilt and to the beam offset, in the presence of the groove, are investigated by simulations. The simulation results show that the axial magnetic field in the central plane of the groove is proportional to the beam tilt and independent on the centroid position. The ratio between the axial magnetic field and the beam tilt depends on the position of the axial B-dot loop and the dimensions of the groove. -- Highlights: •MAFIA simulations were carried out to analyze the influence of recessed groove to axial B dots. •It is found that axial B dots still works in the central plane of the recessed groove. •The dimensions of the groove greatly influence the signal strength of axial B dots. •Results can be used for future optimizations.

  2. Axial traction magnetic resonance imaging (MRI) of the glenohumeral joint in healthy volunteers: initial experience.

    Science.gov (United States)

    Garwood, Elisabeth R; Souza, Richard B; Zhang, Amy; Zhang, Alan L; Ma, C Benjamin; Link, Thomas M; Motamedi, Daria

    Evaluate technical feasibility and potential applications of glenohumeral (GH) joint axial traction magnetic resonance imaging (MRI) in healthy volunteers. Eleven shoulders were imaged in neutral and with 4kg axial traction at 3T. Quantitative measurements were assessed. Axial traction was well tolerated. There was statistically significant widening of the superior GH joint space (p=0.002) and acromial angle (p=0.017) with traction. Inter-rater agreement was high. GH joint axial traction MRI is technically feasible and well tolerated in volunteers. Traction of the capsule, widening of the superior GH joint space and acromial angle were observed. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Significance of axial length monitoring in children with congenital cataract and update of measurement methods.

    Science.gov (United States)

    Zhan, Jiao; Lin, Haotian; Zhang, Xinyu; Chen, Weirong; Liu, Yizhi

    2013-06-01

    Congenital cataract is the main cause of blindness in children, with significantly varying treatment effects. The development of axial length is an important factor that affects the prognosis of these children. However, when compared with the eyes of normal children, the mechanism of growth of the axial length is so complicated that the reported findings differ significantly in terms of the measuring apparatus, assessment methods, and statistical outcome, making the rule of axial length development still unclear. In this paper, we first review the process of axial length development in normal healthy children and compare different hypotheses about certain factors that could affect the development of axial length. The results of some current research about the characteristics of axial length development in congenital cataract children are then reviewed. Lastly, the advantages and disadvantages of current axial length measurements methods are compared and analyzed. The purpose of this review is to improve our understanding of the complexity and importance of axial length development and to suggest better use of axial length monitoring measurements in congenital cataract children for pediatric ophthalmologists, with the hope of offering assistance that will enhance long-term therapeutic effects for these children.

  4. Coupled high Q-factor Surface Nanoscale Axial Photonics (SNAP) microresonators

    CERN Document Server

    Sumetsky, M; DiGiovanni, D J; Dulashko, Y; Fini, J M; Monberg, E

    2011-01-01

    We experimentally demonstrate series of identical two, three, and five coupled high Q-factor Surface Nanoscale Axial Photonics (SNAP) microresonators formed by periodic nanoscale variation of the optical fiber radius. These microresonators are fabricated with a 100 \\mum period along an 18 \\mum radius optical fiber. The axial FWHM of these microresonators is 80 \\mum and their Q-factor exceeds 107. In addition, we demonstrate a SNAP microresonator with the axial FWHM as small as 30 \\mum and the axial FWHM of the fundamental mode as small as 10 \\mum. These results may potentially enable the dense integration of record low loss coupled photonic microdevices on the optical fiber platform.

  5. Frontal chromatography of proteins. Effect of axial dispersion on column performance.

    Science.gov (United States)

    Heeter, G A; Liapis, A I

    1998-02-13

    A mathematical model describing the dynamic adsorption of proteins in columns packed with spherical porous adsorbent particles is used to study the effect of axial dispersion on the performance of chromatographic systems. The values of the axial dispersion coefficient, DL, are estimated from a correlation based on a model describing axial dispersion in packed beds that provides satisfactory results when compared with experiment. Simulations of frontal chromatography in systems including axial dispersion and in systems without axial dispersion are made and compared to determine the effect of axial dispersion on the efficiency of the adsorption process; also, the system parameters that influence axial dispersion are examined. It is found that the reduction in the efficiency of the adsorption process due to axial dispersion is small (< 1%) for columns of length 10 cm or greater. However, for short columns, this efficiency reduction can be as large as 10%. Increasing the adsorbent particle diameter, dp, increases the magnitude of the reduction in efficiency due to axial dispersion; the effect of increasing the adsorbent particle diameter, dp, is much more pronounced in a short column than in a long column.

  6. A cryogenic axial-centrifugal compressor for superfluid helium refrigeration

    CERN Document Server

    Decker, L; Schustr, P; Vins, M; Brunovsky, I; Lebrun, P; Tavian, L

    1997-01-01

    CERN's new project, the Large Hadron Collider (LHC), will use superfluid helium as coolant for its high-field superconducting magnets and therefore require large capacity refrigeration at 1.8 K. This may only be achieved by subatmospheric compression of gaseous helium at cryogenic temperature. To stimulate development of this technology, CERN has procured from industry prototype Cold Compressor Units (CCU). This unit is based on a cryogenic axial-centrifugal compressor, running on ceramic ball bearings and driven by a variable-frequency electrical motor operating under low-pressure helium at ambient temperature. The machine has been commissioned and is now in operation. After describing basic constructional features of the compressor, we report on measured performance.

  7. Electric field generated by axial longitudinal vibration modes of microtubule.

    Science.gov (United States)

    Cifra, M; Pokorný, J; Havelka, D; Kucera, O

    2010-05-01

    Microtubules are electrically polar structures fulfilling prerequisites for generation of oscillatory electric field in the kHz to GHz region. Energy supply for excitation of elasto-electrical vibrations in microtubules may be provided from GTP-hydrolysis; motor protein-microtubule interactions; and energy efflux from mitochondria. We calculated electric field generated by axial longitudinal vibration modes of microtubules for random, and coherent excitation. In case of coherent excitation of vibrations, the electric field intensity is highest at the end of microtubule. The dielectrophoretic force exerted by electric field on the surrounding molecules will influence the kinetics of microtubule polymerization via change in the probability of the transport of charge and mass particles. The electric field generated by vibrations of electrically polar cellular structures is expected to play an important role in biological self-organization. 2010 Elsevier Ireland Ltd. All rights reserved.

  8. Axial dipolar dynamo action in the Taylor-Green vortex.

    Science.gov (United States)

    Krstulovic, Giorgio; Thorner, Gentien; Vest, Julien-Piera; Fauve, Stephan; Brachet, Marc

    2011-12-01

    We present a numerical study of the magnetic field generated by the Taylor-Green vortex. We show that periodic boundary conditions can be used to mimic realistic boundary conditions by prescribing the symmetries of the velocity and magnetic fields. This gives insight into some problems of central interest for dynamos: the possible effect of velocity fluctuations on the dynamo threshold, and the role of boundary conditions on the threshold and on the geometry of the magnetic field generated by dynamo action. In particular, we show that an axial dipolar dynamo similar to the one observed in a recent experiment can be obtained with an appropriate choice of the symmetries of the magnetic field. The nonlinear saturation is studied and a simple model explaining the magnetic Prandtl number dependence of the super- and subcritical nature of the dynamo transition is given.

  9. Axial shape index calculation for the 3-level excore detector

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Han Gon; Kim, Yong Hee; Kim, Byung Sop; Lee, Sang Hee; Cho, Sung Jae [Korea Electric Power Research Institute, Taejon (Korea, Republic of)

    1997-12-31

    A new method based on the alternating conditional expectation (ACE) algorithm is developed to calculate axial shape index (ASI) for the 3-level excore detector. The ACE algorithm, a type of nonparametric regression algorithms, yields an optimal relationship between a dependent variable and multiple independent variables. In this study, the simple correlation between ASI and excore detector signals is developed using the Younggwang nuclear power plant unit 3 (YGN-3) data without any preprocessing on the relationships between independent variables and dependent variable. The numerical results show that simple correlations exist between the three excore signals and ASI of the core. The accuracy of the new method is much better than those of the current CPC and COLSS algorithms. 5 refs., 2 figs., 2 tabs. (Author)

  10. Axial-resolution in depth from focus digital holography

    Science.gov (United States)

    van Rooij, Joseph; Kalkman, Jeroen

    2017-06-01

    We use digital holography to quantify surface topography of rough objects in full-field. We calculate the variance of the intensity image as a focus metric over a set of reconstruction distances for each pixel, which results in a focus metric curve. The distance where the variance peaks is an estimate for the depth. First we analyze the lateral resolution of this method using the Talbot effect and argue that sub-mm axial resolution is feasible. Then, using a Michelson setup without magnifying optics or lateral scanning we experimentally demonstrate that sub-mm FWHM width of the focus curve can be achieved. This is significantly better than what was previously reported using digital holography and could make this technique useful for characterising objects in art and machine vision.

  11. Intestinal dysbiosis and innate immune responses in axial spondyloarthritis.

    Science.gov (United States)

    Ciccia, Francesco; Ferrante, Angelo; Triolo, Giovanni

    2016-07-01

    Inflammatory innate and adaptive immune cell responses to commensal bacteria underlie the pathogenesis of human chronic inflammatory diseases. Intestinal dysbiosis has been described in patients with spondyloarthritis (SpA) and seems to be correlated with histologic and immunologic alterations. Purpose of this review is to discuss the relationship occurring between intestinal dysbiosis and innate immune responses in patients with axial SpA. Intestinal dysbiosis and differential activation of intestinal immune responses in patients with SpA have been demonstrated. Furthermore, innate cells that appear to be involved in the pathogenesis of SpA may control intestinal homeostasis through induction of apoptotic cell death and deletion of activated commensal bacteria-specific T cells. Although the evidence shows that dysbiosis occurs in SpA, it is not clear the role of dysbiosis in regulating innate immune responses in SpA. Relationships between cause and effect remain to be answered. http://links.lww.com/COR/A34.

  12. Seeing the Axial Line: Evidence from Wayfinding Experiments

    Directory of Open Access Journals (Sweden)

    Beatrix Emo

    2014-07-01

    Full Text Available Space-geometric measures are proposed to explain the location of fixations during wayfinding. Results from an eye tracking study based on real-world stimuli are analysed; the gaze bias shows that attention is paid to structural elements in the built environment. Three space-geometric measures are used to explain the data: sky area, floor area and longest line of sight. Together with the finding that participants choose the more connected street, a relationship is proposed between the individual cognitive processes that occur during wayfinding, relative street connectivity measured through space syntactic techniques and the spatial geometry of the environment. The paper adopts an egocentric approach to gain a greater understanding on how individuals process the axial map.

  13. Seeing the axial line: evidence from wayfinding experiments.

    Science.gov (United States)

    Emo, Beatrix

    2014-09-01

    Space-geometric measures are proposed to explain the location of fixations during wayfinding. Results from an eye tracking study based on real-world stimuli are analysed; the gaze bias shows that attention is paid to structural elements in the built environment. Three space-geometric measures are used to explain the data: sky area, floor area and longest line of sight. Together with the finding that participants choose the more connected street, a relationship is proposed between the individual cognitive processes that occur during wayfinding, relative street connectivity measured through space syntactic techniques and the spatial geometry of the environment. The paper adopts an egocentric approach to gain a greater understanding on how individuals process the axial map.

  14. An Axial Sliding Test for machine elements surfaces

    DEFF Research Database (Denmark)

    Godi, Alessandro; Grønbæk, J.; Mohaghegh, Kamran

    2012-01-01

    Throughout the years, it has become more and more important to find new methods for reducing friction and wear occurrence in machine elements. A possible solution is found in texturing the surfaces under tribological contact, hence the development and spread of plateau-honed surface for cylinder...... turned rod against a mirror-polished sleeve. Qualitatively the multifunctional surfaces improve the friction conditions, but a more structured test campaign is required....... liners. To prove the efficacy of a particular textured surface, it is paramount to perform experimental tests under controlled laboratory conditions. In this paper a new test rig simulating pure sliding conditions is presented, dubbed Axial Sliding Test. It presents four major components: a rod, a sleeve...

  15. Predicting the Coupling Properties of Axially-Textured Materials

    Directory of Open Access Journals (Sweden)

    María E. Fuentes-Montero

    2013-10-01

    Full Text Available A description of methods and computer programs for the prediction of “coupling properties” in axially-textured polycrystals is presented. Starting data are the single-crystal properties, texture and stereography. The validity and proper protocols for applying the Voigt, Reuss and Hill approximations to estimate coupling properties effective values is analyzed. Working algorithms for predicting mentioned averages are given. Bunge’s symmetrized spherical harmonics expansion of orientation distribution functions, inverse pole figures and (single and polycrystals physical properties is applied in all stages of the proposed methodology. The established mathematical route has been systematized in a working computer program. The discussion of piezoelectricity in a representative textured ferro-piezoelectric ceramic illustrates the application of the proposed methodology. Polycrystal coupling properties, predicted by the suggested route, are fairly close to experimentally measured ones.

  16. The Three-Axial Earth Rotation: A New Mathematical Approach

    Science.gov (United States)

    Mioc, Vasile; Stavinschi, Magda

    The three-axial Earth's rotation is generally treated by quantitative methods. The seldom used qualitative analysis, which depicts the general evolution all along the motion, can offer supplementary information. Tackling the problem from such a viewpoint, we exploit its Hamiltonian description using Andoyer-type variables, and consider it via KAM (Kolmogorov-Arnold-Moser) theory. The system of motion equations fulfils the condition of so-called "isoenergetic nondegeneracy". In astronomical translation, this means that the Earth's rotation is "sure" for almost all initial conditions: the chances for a drastic change are extremely improbable; this corroborates the data provided by observations and quantitative analysis. Another result offered by KAM theory is that the polhody will always be confined to a relatively negligible area. As a final conclusion, the most various methods of mathematics, classical mechanics, celestial mechanics must be used to understand astronomical problems of essential importance, as the Earth's rotation is.

  17. Spectrum of sight line displacements in the axial meridian circle.

    Science.gov (United States)

    Bakhonskij, A. V.; Kostyuchenko, V. L.; Lazorenko, P. F.

    The authors analyze the residuals Δα cos δ and Δδ obtained in the reduction of star observations made with the axial meridian circle of the Main Astronomical Observatory, National Academy of Sciences of Ukraine. The mean autocorrelation functions, variances, and spectra are given. The averaging allowed for the bias of sample functions for finite measurement runs. The spectra expressed in [open square]″Hz are fitted by the two-component models g(f) = 563(T0f)-2.2+7.0 and g(f) = 242(T0f)-1.5+5.1 for right ascension and declination residuals, respectively, with T0 = 18000 s. The data are compared with those for the Bordeaux meridian circle of the classical type. The spectral low-frequency component is shown to be produced by thermal deformations of the instrument tube.

  18. Endoscopic Transoral Resection of an Axial Chordoma: A Case Report

    Directory of Open Access Journals (Sweden)

    Taran S

    2015-11-01

    Full Text Available Upper cervical chordoma (UCC is rare condition and poses unique challenges to surgeons. Even though transoral approach is commonly employed, a minimally invasive technique has not been established. We report a 44-year old Malay lady who presented with a 1 month history of insidious onset of progressive neck pain without neurological symptoms. She was diagnosed to have an axial (C2 chordoma. Intralesional resection of the tumour was performed transorally using the Destandau endoscopic system (Storz, Germany. Satisfactory intralesional excision of the tumour was achieved. She had a posterior fixation of C1-C4 prior to that. Her symptoms improved postoperatively and there were no complications noted. She underwent adjuvant radiotherapy to minimize local recurrence. Endoscopic excision of UCC via the transoral approach is a safe option as it provides an excellent magnified view and ease of resection while minimizing the operative morbidity.

  19. Axially-Symmetric Radiation Field of Conical Monopole

    Science.gov (United States)

    Kuryliak, D. B.; Sharabura, O. M.

    2013-12-01

    The rigorous solution of the problem of axially-symmetric, TM-wave diffraction by the open end of the biconical scatterer,, whose one arm is a semi-infinite cone and the other - a finite, cone, is obtained. The bicone is irradiated by the ring magnetic, current field. The analytical regularization technique is applied, to obtain the problem solution. The limiting transition from the, biconical scatterer with arbitrary values of angular parameters, to the monopole antenna (a finite hollow cone above the plane), is performed. The influence of the monopole's geometrics and, the source location on the far-field patterns is investigated. In particular cases, the results are compared with the known data.

  20. Treatment with tumor necrosis factor inhibitors in axial spondyloarthritis

    DEFF Research Database (Denmark)

    Ciurea, A.; Weber, U.; Stekhoven, D.

    2015-01-01

    Objective. To evaluate the initiation of and response to tumor necrosis factor (TNF) inhibitors for axial spondyloarthritis (axSpA) in private rheumatology practices versus academic centers. The Journal of Rheumatology, Methods.We compared newly initiated TNF inhibition for axSpA in 363 patients...... was slightly higher in the hospital setting. Mean levels (+/- SD) of the Ankylosing Spondylitis Disease Activity Score were, however, virtually identical in private practices and academic centers (3.4 +/- 1.0 vs 3.4 +/- 0.9, p = 0.68). An Assessment of SpondyloArthritis international Society (ASAS40) response...... in private practices in comparison to academic centers, adherence to ASAS treatment recommendations for TNF inhibition was equally high, and similar response rates to TNF blockers were achieved in both clinical settings. (First Release Nov 1 2014; J Rheumatol 2015; 42:101-5; doi 10.3899/jrheum.140229)....

  1. Numerical Algorithms for Boundary Problems with Disturbed Axial Symmetry

    Energy Technology Data Exchange (ETDEWEB)

    Ivanov, V

    2004-03-26

    The axial symmetry in the real devices of image electron optics is always disturbed by small defects in manufacturing and assembly. The authors present a complete method for the numerical simulation of problems with such defects, which includes the algorithms for singularity extraction in a numerical solution of the boundary problem described by the Helmholtz equation. The effective recurrent formulas for evaluation of the kernels of integral representations and their derivatives are constructed. New modification of the well-known Bruns-Bertein method is given, and correlation of this method with an integral equation in variations is investigated. The algorithms are implemented in the codes POISSON-2 and OPTICS-2. The results of the numerical simulation for various test problems with different kinds of boundary deformation are given.

  2. Operational Experience with a Cryogenic Axial-Centrifugal Compressor

    CERN Document Server

    Decker, L; Löhlein, K; Purtschert, W; Ziegler, B L; Lebrun, P; Tavian, L; Brunovsky, I; Tucek, L

    1998-01-01

    The Large Hadron Collider (LHC), presently under construction at CERN, requires large refrigeration capacity at 1.8 K. Compression of gaseous helium at cryogenic temperatures is therefore inevitable. Together with subcontractors, Linde Kryotechnik has developed a prototype machine. This unit is based on a cryogenic axial-centrifugal compressor, running on ceramic ball bearings and driven by a variable-frequency electrical motor operating at ambient temperature. Integrated in a test facility for superconducting magnets the machine has been commissioned without major problems and successfully gone through the acceptance test in autumn 1995. Subsequent steps were initiated to improve efficiency of this prototype. This paper describes operating experience gained so far and reports on measured performance prior to and after constructional modifications.

  3. Characteristic experiment of swashplate type axial piston motor (I)

    Energy Technology Data Exchange (ETDEWEB)

    Yum, M.O. [Kyongnam National University, Masan (Korea); Yoon, I.R. [Kyongnam National University Graduate School, Masan (Korea)

    2000-04-01

    The purpose of this study is to construct a testing equipment with which several characteristics of the domestically developed swashplate type axial piston motor can be tested and to develop a software with which the data from experiment can be stored and can be applied. The results of the study are as follows; 1) The leakage flow and the torque of the motor being stopped is proportional to supply pressure and their relation can be showed by linear equations. 2) The motor movement is not smooth below 50 rpm but it moves smoothly up 170 rpm. 3) When the motor starts or stops, the pressure rise ratio effects decisively to the max. torque. (author). 7 refs., 12 figs., 2 tabs.

  4. Structures of water molecular nanotube induced by axial tensile strains

    Energy Technology Data Exchange (ETDEWEB)

    Li, H. [Key Laboratory of Liquid Structures and Heredity of Materials, Ministry of Education, School of Materials Science and Engineering, Shandong University (China)], E-mail: lihuilmy@hotmail.com; Zhang, X.Q. [Physics Department, Ocean University of China, Qingdao (China); Liew, K.M. [Department of Building and Constructions, City University of Hong Kong, Kowloon (Hong Kong); Liu, X.F. [Key Laboratory of Liquid Structures and Heredity of Materials, Ministry of Education, School of Materials Science and Engineering, Shandong University (China)

    2008-10-06

    Five well-ordered nano-ice structures embedded in carbon nanotubes are obtained in this study. These five nano-ice phases all exhibit single walled tubular morphologies, including the pentagon, hexagon ice nanotubes whose structures are quite different from bulk ice. Our simulation results indicate that water molecules tend to rearrange into surface ring structures to reduce the number of free OH groups. The structural behavior of these ice nanotubes inside CNTs subject to axial stress is also investigated. The ice nanotubes tend to be drawn to ice nanorings or ice nanospring during the mechanical stretching. The distribution function exhibits typical order-to-disorder transition of the water network confined in carbon nanotube during the stretching. By analysis, we suggest that it is unlikely that additional water molecules will enter the tubes because of the increased volume available if the tubes are stretched at contact with a water reservoir.

  5. Simulation of the stationary particle distribution in axial channeling

    Energy Technology Data Exchange (ETDEWEB)

    Pokhyl, G.P.; Cherdyntsev, V.V. (Moskovskij Gosudarstvennyj Univ. (USSR). Nauchno-Issledovatel' skij Inst. Yadernoj Fiziki)

    1982-01-01

    A mathematical model is developed for particle distribution in axial channeling through crystals. Results are shown for particle distribution in the transverse plane for various depths and initial conditions in (a) W <100> and (b) Si <100>. The distribution of impact parameters of the particle-string collisions was studied as a function of depth. The distribution function in the transverse plane for a single particle is plotted as its trajectory is traced to 0.2 mm depths at E(transverse) = 0.4 Esub(c) in W <100> (where E(transverse) is the energy of transverse motion and Esub(c) is the Lindhard critical energy of transverse motion).

  6. Active surge control for variable speed axial compressors.

    Science.gov (United States)

    Lin, Shu; Yang, Chunjie; Wu, Ping; Song, Zhihuan

    2014-09-01

    This paper discusses active surge control in variable speed axial compressors. A compression system equipped with a variable area throttle is investigated. Based on a given compressor model, a fuzzy logic controller is designed for surge control and a proportional speed controller is used for speed control. The fuzzy controller uses measurements of the change of pressure rise as well as the change of mass flow to determine the throttle opening. The presented approach does not require the knowledge of system equilibrium or the surge line. Numerical simulations show promising results. The proposed fuzzy logic controller performs better than a backstepping controller and is capable to suppress surge at different operating points. Copyright © 2014 ISA. Published by Elsevier Ltd. All rights reserved.

  7. Thermoacoustic mixture separation with an axial temperature gradient

    Energy Technology Data Exchange (ETDEWEB)

    Geller, Drew W [Los Alamos National Laboratory; Swift, Gregory A [Los Alamos National Laboratory

    2008-01-01

    The theory of thermoacoustic mixture separation is extended to include the effect of a nonzero axial temperature gradient. The analysis yields a new term in the second-order mole flux that is proportional to the temperature gradient and to the square of the volumetric velocity and is independent of the phasing of the wave. Because of this new term, thermoacoustic separation stops at a critical temperature gradient and changes direction above that gradient. For a traveling wave, this gradient is somewhat higher than that predicted by a simple four-step model. An experiment tests the theory for temperature gradients from 0 to 416 K/m in 50-50 He-Ar mixtures.

  8. Collimation of laser-produced plasmas using axial magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Roy, Amitava; Harilal, Sivanandan S.; Hassan, Syed M.; Endo, Akira; Mocek, Tomas; Hassanein, A.

    2015-06-01

    We investigated the expansion dynamics of laser-produced plasmas expanding into an axial magnetic field. Plasmas were generated by focusing 1.064 µm Nd:YAG laser pulses onto a planar tin target in vacuum and allowed to expand into a 0.5 T magnetic-filed where field lines were aligned along the plume expansion direction. Gated images employing intensified CCD showed focusing of the plasma plume, which were also compared with results obtained using particle-in-cell modelling methods. The estimated density and temperature of the plasma plumes employing emission spectroscopy revealed significant changes in the presence and absence of the 0.5T magnetic field. In the presence of the field, the electron temperature is increased with distance from the target, while the density showed opposite effects.

  9. New turbomolecular pump with central opening for free axial access

    CERN Document Server

    Mokler, P H

    2004-01-01

    Standard turbomolecular pumps show typically one annular active intake area on the high vacuum flange side (single-flow pumps). The central circular part of the inlet of the compressor turbine is blind for pumping. The new design proposes a central opening of a turbomolecular pump all along the axis. This central bore can be used e.g. for mounting of feed throughs, manipulators, windows or for coupling to further vacuum devices, in particular also for enclosing tube-like vacuum systems. This design allows a multi-use of a pumping port at a vacuum vessel without reducing there the pumping speed. Moreover, the new design is ideal for axial or radial differential pumping arrangements as e.g. needed for all gas jet like set-ups or other pressure reduction stages.

  10. Three-dimensional equilibria in axially symmetric tokamaks

    Science.gov (United States)

    Garabedian, Paul R.

    2006-01-01

    The NSTAB and TRAN computer codes have been developed to study equilibrium, stability, and transport in fusion plasmas with three-dimensional (3D) geometry. The numerical method that is applied calculates islands in tokamaks like the Doublet III-D at General Atomic and the International Thermonuclear Experimental Reactor. When bifurcated 3D solutions are used in Monte Carlo computations of the energy confinement time, a realistic simulation of transport is obtained. The significance of finding many 3D magnetohydrodynamic equilibria in axially symmetric tokamaks needs attention because their cumulative effect may contribute to the prompt loss of α particles or to crashes and disruptions that are observed. The 3D theory predicts good performance for stellarators. PMID:17159158

  11. Avaliação cefalométrica radiográfica da posição craniocervical de pacientes orientados em posição natural da cabeça pré e pós-expansão rápida da maxila Cephalometric radiographic evaluation of the craniocervical position of patients oriented in natural head position before and after the rapid maxillary expansion

    Directory of Open Access Journals (Sweden)

    Belini Augusto Villalba Freire-Maia

    2005-04-01

    Full Text Available O objetivo deste estudo foi avaliar a eventual alteração na posição craniocervical de pacientes orientados na Posição Natural da Cabeça (PNC, após o procedimento de expansão rápida da maxila (ERM. Utilizaram-se telerradiografias em norma lateral, selecionadas do acervo de documentação da Clínica de Ortodontia Preventiva da Faculdade de Odontologia da Universidade de São Paulo, de 20 pacientes, com idades entre 5 a 11 anos (média de 9,0 anos, sendo 7 do gênero masculino e 13 do feminino, obtidas no início do tratamento e imediatamente após a fase ativa da expansão da maxila. Os pacientes eram portadores de atresia da maxila e foram tratados com aparelho disjuntor tipo Biederman modificado. A partir dos cefalogramas pré e pós-ERM foram obtidas as grandezas angulares craniovertical (SN.VER, craniocervical (OPT.SN e CVT.SN, cervicohorizontal (OPT.HOR, CVT.HOR e o ângulo da curvatura cervical (OPT.CVT. Após análise estatística e interpretação dos resultados obtidos concluímos que a posição da cabeça não apresentou alteração estatisticamente significativa. Não foram observadas diferenças estatisticamente significativas entre os gêneros quando comparadas as fases pré e pós-ERM para as grandezas estudadas. O método de obtenção de telerradiografias laterais em Orientação Natural da Cabeça mostrou-se confiável e reproduzível na amostra estudada, mesmo na presença de intervenção ortodôntica-ortopédica entre as séries de radiografias.The aim of this study was to evaluate the eventual alteration in the craniocervical position of patients, oriented in the Natural Head Position (NHP, after the rapid maxillary expansion (RME procedure. We have used lateral radiographs, selected from the documentation file of the Preventive Orthodontics Clinic, School of Dentistry, University of São Paulo. Our sample consisted of 20 patients (7M:13F, with ages ranging from 5.08 up to 11.08 years (mean of 9,0. The

  12. Investigation of Two-Phase Flow in AxialCentrifugal Impeller by Hydrodynamic Modeling Methods

    Directory of Open Access Journals (Sweden)

    V. O. Lomakin

    2014-01-01

    Full Text Available The article provides a methodology to study the flow in the wet part of the pump with fundamentally new axial-centrifugal impeller by methods of hydrodynamic modeling in the software package STAR CCM +. The objective of the study was to determine the normal and cavitation characteristics of the pump with a new type of wet part, as well as optimization of the geometrical parameters of the pump. Authors solved this problem using an example of the hot coolant pump, which should meet high requirements for cavitation quality and efficiency (hydraulic efficiency up to 87%, critical value of NPSH to 2.2 m.Also, the article focuses on the methods of numerical solution of two-phase flow simulation in a pump that are needed for a more accurate simulation of cavitation in the pump and research work in liquids with high gas content.Hydrodynamic modeling was performed on a computing cluster at the department E-10 of BMSTU for pump flow simulation in unsteady statement of problem using the computational grid size to 1.5 million cells. Simultaneously, the experimental model of the pump was made by 3D printing and tested at the stand in the BMSTU. Test results, which were compared with the calculated data are also given in the article. Inaccuracy of the calculation of pump head does not exceed 5%.The simulation results may be of interest to specialists in the field of hydrodynamic modeling, and for designers of such pumps. The authors also report production of a full-length prototype of the pump in order to conduct further testing for the verification of the data in the article, primarily in terms of cavitation characteristics.

  13. 49 CFR 572.182 - Head assembly.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 7 2010-10-01 2010-10-01 false Head assembly. 572.182 Section 572.182... Dummy, 50th Percentile Adult Male § 572.182 Head assembly. (a) The head assembly consists of the head... assembly shall meet performance requirements specified in paragraph (c) of this section. (b) Test procedure...

  14. Hysteretic Models Considering Axial-Shear-Flexure Interaction

    Science.gov (United States)

    Ceresa, Paola; Negrisoli, Giorgio

    2017-10-01

    Most of the existing numerical models implemented in finite element (FE) software, at the current state of the art, are not capable to describe, with enough reliability, the interaction between axial, shear and flexural actions under cyclic loading (e.g. seismic actions), neglecting crucial effects for predicting the nature of the collapse of reinforced concrete (RC) structural elements. Just a few existing 3D volume models or fibre beam models can lead to a quite accurate response, but they are still computationally inefficient for typical applications in earthquake engineering and also characterized by very complex formulation. Thus, discrete models with lumped plasticity hinges may be the preferred choice for modelling the hysteretic behaviour due to cyclic loading conditions, in particular with reference to its implementation in a commercial software package. These considerations lead to this research work focused on the development of a model for RC beam-column elements able to consider degradation effects and interaction between the actions under cyclic loading conditions. In order to develop a model for a general 3D discrete hinge element able to take into account the axial-shear-flexural interaction, it is necessary to provide an implementation which involves a corrector-predictor iterative scheme. Furthermore, a reliable constitutive model based on damage plasticity theory is formulated and implemented for its numerical validation. Aim of this research work is to provide the formulation of a numerical model, which will allow implementation within a FE software package for nonlinear cyclic analysis of RC structural members. The developed model accounts for stiffness degradation effect and stiffness recovery for loading reversal.

  15. Axial ion-electron emission microscopy of IC radiation hardness

    Science.gov (United States)

    Doyle, B. L.; Vizkelethy, G.; Walsh, D. S.; Swenson, D.

    2002-05-01

    A new system for performing radiation effects microscopy (REM) has been developed at Sandia National Laboratory in Albuquerque. This system combines two entirely new concepts in accelerator physics and nuclear microscopy. A radio frequency quadrupole (RFQ) linac is used to boost the energy of ions accelerated by a conventional Tandem Van de Graaff-Pelletron to velocities of 1.9 MeV/amu. The electronic stopping power for heavy ions is near a maximum at this velocity, and their range is ˜20 μm in Si. These ions therefore represent the most ionizing form of radiation in nature, and are nearly ideal for performing single event effects testing of integrated circuits. Unfortunately, the energy definition of the RFQ-boosted ions is rather poor (˜ a few %), which makes problematic the focussing of such ions to the submicron spots required for REM. To circumvent this problem, we have invented ion electron emission microscopy (IEEM). One can perform REM with the IEEM system without focussing or scanning the ion beam. This is because the position on the sample where each ion strikes is determined by projecting ion-induced secondary electrons at high magnification onto a single electron position sensitive detector. This position signal is then correlated with each REM event. The IEEM system is now mounted along the beam line in an axial geometry so that the ions pass right through the electron detector (which is annular), and all of the electrostatic lenses used for projection. The beam then strikes the sample at normal incidence which results in maximum ion penetration and removes a parallax problem experienced in an earlier system. Details of both the RFQ-booster and the new axial IEEM system are given together with some of the initial results of performing REM on Sandia-manufactured radiation hardened integrated circuits.

  16. Analysis of brushless DC generator incorporating an axial field coil

    Energy Technology Data Exchange (ETDEWEB)

    Moradi, Hassan, E-mail: H_moradi@sbu.ac.i [Department of Electrical and Computer Engineering, Shahid Beheshti University, GC, Tehran (Iran, Islamic Republic of); Afjei, E. [Department of Electrical and Computer Engineering, Shahid Beheshti University, GC, Tehran (Iran, Islamic Republic of)

    2011-07-15

    Highlights: {yields} Magnetic analysis and experiment of a three-phase field assisted BLDC generator. {yields} Confirm the accuracy of the predicted flux-linkage by 2-D FE analysis. {yields} Confirm the accuracy of the FE analysis results by coupling the FE and BE method. {yields} Control the output voltage to a desired level by control the amplitude of the I{sub f}. {yields} Compatible with any application that requires variable speed operation. -- Abstract: This paper describes the magnetic analysis and experiment of a three-phase field assisted brushless DC (BLDC) generator. Unlike conventional BLDC generators, the permanent magnet is replaced with an assisted field winding. The stator and rotor are constructed with two dependent magnetically sets, in which each stator set includes nine salient poles with coil windings, and the rotor comprises of six salient poles. Other pole combinations also are possible. This construction is similar to a homopolar inductor alternator. The DC current in the assisted field winding produces axial flux which makes the rotor magnetically polarized at its ends. The magnetic field flows axially through the rotor shaft and closes through the stator teeth and the machine housing. To evaluate the generator performance, two types of analysis, namely the numerical technique and the experimental study have been utilized. In the numerical analysis, 2-D finite element (FE) analysis has been carried out using a MagNet CAD package (Infolytica Corporation Ltd.), to confirm the accuracy of the predicted flux-linkage characteristics, whereas in the experimental study, a prototype BLDC generator was constructed for verifying the actual performance. Furthermore, the evaluation method based on a hybrid numerical method coupling the finite element (FE) analysis and boundary element (BE) method, has been carried out to confirm the accuracy of the 2-D FE analysis simulation results. It provides not only confirmations of the investigation in results

  17. Axial turbomachine modelling with a 1D axisymmetric approach

    Energy Technology Data Exchange (ETDEWEB)

    Tauveron, Nicolas [Commissariat a l' Energie Atomique, Direction de l' Energie Nucleaire, 17 rue des Martyrs, 38100 Grenoble (France)]. E-mail: nicolas.tauveron@cea.fr; Saez, Manuel [Commissariat a l' Energie Atomique, Direction de l' Energie Nucleaire, 17 rue des Martyrs, 38100 Grenoble (France)]. E-mail: manuel.saez@cea.fr; Ferrand, Pascal [Laboratoire de Mecanique des Fluides et d' Acoustique, Ecole Centrale de Lyon, 36 avenue de Collongue, 69134 Ecully Cedex (France)]. E-mail: pascal.ferrand@ec-lyon.fr; Leboeuf, Francis [Laboratoire de Mecanique des Fluides et d' Acoustique, Ecole Centrale de Lyon, 36 avenue de Collongue, 69134 Ecully Cedex (France)]. E-mail: francis.leboeuf@ec-lyon.fr

    2007-09-15

    This work concerns the design and safety analysis of direct cycle gas cooled reactor. The estimation of compressor and turbine performances in transient operations is of high importance for the designer. The first goal of this study is to provide a description of compressor behaviour in unstable conditions with a better understanding than the models based on performance maps ('traditional' 0D approach). A supplementary objective is to provide a coherent description of the turbine behaviour. The turbomachine modelling approach consists in the solution of 1D axisymmetric Navier-Stokes equations on an axial grid inside the turbomachine: mass, axial momentum, circumferential momentum and total-enthalpy balances are written. Blade forces are taken into account by using compressor or turbine blade cascade steady correlations. A particular effort has been developed to generate or test correlations in low mass flow and negative mass flow regimes, based on experimental data. The model is tested on open literature cases of the gas turbine aircraft community. For compressor and turbine, steady situations are fairly described, especially for medium and high mass flow rate. The dynamic behaviour of compressor is also quite well described, even in unstable operation (surge): qualitative tendencies (role of plenum volume and role of throttle) and some quantitative characteristics (frequency) are in a good agreement with experimental data. The application to transient simulations of gas cooled nuclear reactors is concentrated on the hypothetical 10 in. break accident. The results point out the importance of the location of the pipe rupture in a hypothetical break event. In some detailed cases, compressor surge and back flow through the circuit can occur. In order to be used in a design phase, a simplified model of surge has also been developed. This simplified model is applied to the gas fast reactor (GFR) and compared quite favourably with 1D axisymmetric simulation

  18. Axial magnetic field injection in magnetized liner inertial fusion

    Science.gov (United States)

    Gourdain, P.-A.; Adams, M. B.; Davies, J. R.; Seyler, C. E.

    2017-10-01

    MagLIF is a fusion concept using a Z-pinch implosion to reach thermonuclear fusion. In current experiments, the implosion is driven by the Z-machine using 19 MA of electrical current with a rise time of 100 ns. MagLIF requires an initial axial magnetic field of 30 T to reduce heat losses to the liner wall during compression and to confine alpha particles during fusion burn. This field is generated well before the current ramp starts and needs to penetrate the transmission lines of the pulsed-power generator, as well as the liner itself. Consequently, the axial field rise time must exceed hundreds of microseconds. Any coil capable of being submitted to such a field for that length of time is inevitably bulky. The space required to fit the coil near the liner, increases the inductance of the load. In turn, the total current delivered to the load decreases since the voltage is limited by driver design. Yet, the large amount of current provided by the Z-machine can be used to produce the required 30 T field by tilting the return current posts surrounding the liner, eliminating the need for a separate coil. However, the problem now is the field penetration time, across the liner wall. This paper discusses why skin effect arguments do not hold in the presence of resistivity gradients. Numerical simulations show that fields larger than 30 T can diffuse across the liner wall in less than 60 ns, demonstrating that external coils can be replaced by return current posts with optimal helicity.

  19. Development of Lorentz force-type self-bearing motor for an alternative axial flow blood pump design.

    Science.gov (United States)

    Lim, Tau Meng; Zhang, Dongsheng

    2006-05-01

    A Lorentz force-type self-bearing motor was developed to provide delivery of both motoring torque and levitation force for an alternative axial flow blood pump design with an enclosed impeller. The axial flow pumps currently available introduce electromagnetic coupling from the motor's stator to the impeller by means of permanent magnets (PMs) embedded in the tips of the pump's blades. This design has distinct disadvantages, for example, pumping efficiency and electromagnetic coupling transmission are compromised by the constrained or poor geometry of the blades and limited pole width of the PMs, respectively. In this research, a Lorentz force-type self-bearing motor was developed. It is composed of (i) an eight-pole PM hollow-cylindrical rotor assembly supposedly to house and enclose the impeller of an axial flow blood pump, and (ii) a six-pole stator with two sets of copper wire and different winding configurations to provide the motoring torque and levitating force for the rotor assembly. MATLAB's xPC Target interface hardware was used as the rapid prototyping tool for the development of the controller for the self-bearing motor. Experimental results on a free/simply supported rotor assembly validated the design feasibility and control algorithm effectiveness in providing both the motoring torque and levitation force for the rotor. When levitated, a maximum orbital displacement of 0.3 mm corresponding to 1050 rpm of the rotor was measured by two eddy current probes placed in the orthogonal direction. This design has the advantage of eliminating the trade-off between motoring torques, levitating force, and pumping efficiency of previous studies. It also indicated the benefits of enclosed-impeller design as having good dynamic response, linearity, and better reliability. The nonmechanical contact feature between rotating and stationary parts will further reduce hemolysis and thromboembolitic tendencies in a typical blood pump application.

  20. Heading for a fall? Management of head injury in infants.

    LENUS (Irish Health Repository)

    Williamson, M

    2010-09-01

    Head injury is one of the commonest reasons for infants (< 1 year) to attend the Emergency Department (ED). Clinical management varies considerably and concern about non accidental injury results in a high admission rate in some hospitals. Information was obtained on 103 children under one year of age presenting to the ED with head injury in a prospective study. The average age was 6.7 months and 57% of patients were male. Twenty eight babies had skull x rays with 1 skull fracture diagnosed. None required CT brain scan. Ninety eight (94%) were discharged home from the ED. There were no unplanned returns, readmissions or adverse events. The incidence of traumatic brain injury in children under one year of age presenting with head injury is low and the majority can be safely discharged home.