WorldWideScience

Sample records for rapid antibody tests

  1. evaluation of a rapid test for hiv antibodies in saliva and blood

    African Journals Online (AJOL)

    To test whole blood and saliva for HIV antibodies. (anti-HIV) using a rapid test strip capillary flow . immunoassay ... Design. A prospective pilot study of selected HIV-positive and ... defined by the underlying illness or condition is illustrated in.

  2. Evaluation of a rapid test for HIV antibodies in saliva and blood ...

    African Journals Online (AJOL)

    Objective. To test whole blood and saliva for HIV antibodies (anti-HIV) using a rapid test strip capillary flow . immunoassay, and to correlate the test strip results with blood specimen results obtained from routine diagnostic antiHIV assays. Design. A prospective pilot study of selected HIV-positive and HIV-negative individuals ...

  3. Human anti-HIV IgM detection by the OraQuick ADVANCE® Rapid HIV 1/2 Antibody Test.

    Science.gov (United States)

    Guillon, Geraldine; Yearwood, Graham; Snipes, Casey; Boschi, Daniel; Reed, Michael R

    2018-01-01

    The Centers for Disease Control and Prevention (CDC) and many public health jurisdictions continue to advocate for the most sensitive rapid HIV test that is available. Currently, the recommendation is to utilize tests that can detect HIV infection biomarkers within 30 days of infection, when initial immune responses are mounted. The infected patient's IgM response is often used to detect acute infection within a 20-25 days window after infection. This requirement applies to lab-based testing with automated analyzers and rapid, point of care (POC) testing used for screening in a non-clinical setting. A recent study has demonstrated that POC tests using a Protein A-based detection system can detect samples with predominantly HIV-1 IgM reactivity (Moshgabadi et al., 2015). The OraQuick ADVANCE ® Rapid HIV-1/2 Antibody Test (OraQuick ADVANCE ®) also uses Protein A as the detection protein in the antibody-binding colloidal gold conjugate, so it is expected that the OraQuick ADVANCE ® Test will also detect samples with predominantly IgM reactivity. This report definitively demonstrates that the OraQuick ADVANCE ® Test can detect IgM antibodies during an acute infection window period of approximately 20-25 days after infection, and is therefore suitable for use in testing environments requiring adherence to current CDC recommendations.

  4. Radiometric cytolysis inhibition assay, a new rapid test for neutralizing antibodies to intact and trypsin-cleaved poliovirus

    International Nuclear Information System (INIS)

    Hovi, T.; Roivainen, M.

    1989-01-01

    We have developed a new rapid test, the radiometric cytolysis inhibition assay (RACINA), for the determination of neutralizing poliovirus antibodies. HeLa cells prelabeled with 51 Cr, [ 3 H]leucine, or, preferentially, with [ 3 H]uridine are used as sensitive quantitative indicators of residual infectious virus. Both suspensions and monolayer cultures of the indicator cells can be used. Neutralization of a fraction of a high-titer virus preparation can be scored after the first replication cycle at 8 to 10 h. By lowering the incubation temperature to 30 degree C, the completion of the cytolysis due to the first replication cycle of poliovirus was delayed beyond 21 h. This makes it possible to use the RACINA, unlike the standard microneutralization assay, for measuring antibodies to trypsin-cleaved polioviruses. The RACINA was found to be as sensitive as and more reproducible than the standard microneutralization assay in the measurement of neutralizing poliovirus antibodies. The RACINA is a rapid and reliable test for neutralizing antibodies and in principle it may be applicable for quantitation of neutralizing antibodies to other cytolytic agents as well

  5. Rapid screening of monoclonal antibodies: new 'microstick' radioimmunoassay

    International Nuclear Information System (INIS)

    Scheinberg, D.A.; Strand, M.; Wilsnack, R.

    1983-01-01

    A new system for assaying monoclonal antibodies consisting of an 8 x 12 array of sticks which fits into a 96-well microtiter plate is described. Tests using virus specific monoclonal antibodies and virus proteins demonstrated sensitivity equivalent to the conventional microtiter plate assay. Antibody production, antigen specific antibody, and immunoglobulin isotypes could be measured under sterile conditions directly in the original fusion mixture wells and much greater rapidity than with the microtiter plate assay. (Auth.)

  6. Evaluation of three commercial rapid tests for detecting antibodies to human immunodeficiency virus.

    Science.gov (United States)

    Ng, K P; Saw, T L; Baki, A; Kamarudin, R

    2003-08-01

    Determine HIV-1/2, Chembio HIV-1/2 STAT-PAK and PenTest are simple/rapid tests for the detection of antibodies to HIV-1 and HIV-2 in human whole blood, serum and plasma samples. The assay is one step and the result is read visually within 15 minutes. Using 92 known HIV-1 reactive sera and 108 known HIV-1 negative sera, the 3 HIV tests correctly identified all the known HIV-1 reactive and negative samples. The results indicated that Determine HIV-1/2, Chembio HIV-1/2 STAT-PAK and PenTest HIV are as sensitive and specific (100% concordance) as Microparticle Enzyme Immunoassay. The data indicated that these 3 HIV tests are effective testing systems for diagnosis of HIV infection in a situation when the conventional Enzyme Immunoassay is not suitable.

  7. Risk of iatrogenic human immunodeficiency virus infection through transfusion of blood tested by inappropriately stored or expired rapid antibody assays in a Zambian hospital

    NARCIS (Netherlands)

    Consten, E. C.; van der Meer, J. T.; de Wolf, F.; Heij, H. A.; Henny, P. C.; van Lanschot, J. J.

    1997-01-01

    BACKGROUND: The purpose of this study was to estimate the risk of human immunodeficiency virus (HIV) infection via the transfusion of blood tested by inappropriately stored or expired rapid antibody assays in Zambia. STUDY DESIGN AND METHODS: Surgical patients (n = 370) were tested with antibody

  8. Comparison of Xpert Flu rapid nucleic acid testing with rapid antigen testing for the diagnosis of influenza A and B.

    Science.gov (United States)

    DiMaio, Michael A; Sahoo, Malaya K; Waggoner, Jesse; Pinsky, Benjamin A

    2012-12-01

    Influenza infections are associated with thousands of hospital admissions and deaths each year. Rapid detection of influenza is important for prompt initiation of antiviral therapy and appropriate patient triage. In this study the Cepheid Xpert Flu assay was compared with two rapid antigen tests, BinaxNOW Influenza A & B and BD Directigen EZ Flu A+B, as well as direct fluorescent antibody testing for the rapid detection of influenza A and B. Using real-time, hydrolysis probe-based, reverse transcriptase PCR as the reference method, influenza A sensitivity was 97.3% for Xpert Flu, 95.9% for direct fluorescent antibody testing, 62.2% for BinaxNOW, and 71.6% for BD Directigen. Influenza B sensitivity was 100% for Xpert Flu and direct fluorescent antibody testing, 54.5% for BinaxNOW, and 48.5% for BD Directigen. Specificity for influenza A was 100% for Xpert Flu, BinaxNOW, and BD Directigen, and 99.2% for direct fluorescent antibody testing. All methods demonstrated 100% specificity for influenza B. These findings support the use of the Xpert Flu assay in settings requiring urgent diagnosis of influenza A and B. Copyright © 2012 Elsevier B.V. All rights reserved.

  9. The diagnostic sensitivity of dengue rapid test assays is significantly enhanced by using a combined antigen and antibody testing approach.

    Directory of Open Access Journals (Sweden)

    Scott R Fry

    2011-06-01

    Full Text Available BACKGROUND: Serological tests for IgM and IgG are routinely used in clinical laboratories for the rapid diagnosis of dengue and can differentiate between primary and secondary infections. Dengue virus non-structural protein 1 (NS1 has been identified as an early marker for acute dengue, and is typically present between days 1-9 post-onset of illness but following seroconversion it can be difficult to detect in serum. AIMS: To evaluate the performance of a newly developed Panbio® Dengue Early Rapid test for NS1 and determine if it can improve diagnostic sensitivity when used in combination with a commercial IgM/IgG rapid test. METHODOLOGY: The clinical performance of the Dengue Early Rapid was evaluated in a retrospective study in Vietnam with 198 acute laboratory-confirmed positive and 100 negative samples. The performance of the Dengue Early Rapid in combination with the IgM/IgG Rapid test was also evaluated in Malaysia with 263 laboratory-confirmed positive and 30 negative samples. KEY RESULTS: In Vietnam the sensitivity and specificity of the test was 69.2% (95% CI: 62.8% to 75.6% and 96% (95% CI: 92.2% to 99.8 respectively. In Malaysia the performance was similar with 68.9% sensitivity (95% CI: 61.8% to 76.1% and 96.7% specificity (95% CI: 82.8% to 99.9% compared to RT-PCR. Importantly, when the Dengue Early Rapid test was used in combination with the IgM/IgG test the sensitivity increased to 93.0%. When the two tests were compared at each day post-onset of illness there was clear differentiation between the antigen and antibody markers. CONCLUSIONS: This study highlights that using dengue NS1 antigen detection in combination with anti-glycoprotein E IgM and IgG serology can significantly increase the sensitivity of acute dengue diagnosis and extends the possible window of detection to include very early acute samples and enhances the clinical utility of rapid immunochromatographic testing for dengue.

  10. Development and testing of monoclonal antibody-based rapid immunodiagnostic test kits for direct detection of Vibrio cholerae O139 synonym Bengal.

    Science.gov (United States)

    Hasan, J A; Huq, A; Nair, G B; Garg, S; Mukhopadhyay, A K; Loomis, L; Bernstein, D; Colwell, R R

    1995-11-01

    We report on the development and testing of two monoclonal antibody-based rapid immunodiagnostic test kits, BengalScreen, a coagglutination test, and Bengal DFA, a direct fluorescent-antibody test, for direct detection of Vibrio cholerae O139 synonym Bengal in clinical and environmental specimens. The BengalScreen test requires less than 5 min to complete and can be used in the field. Bengal DFA, being more sensitive than BengalScreen, requires only one reagent and less than 20 min for detection and enumeration of V. cholerae O139 synonym Bengal. In tests for specificity, all 40 strains of V. cholerae O139 reacted with both test kits, whereas 157 strains of heterologous species examined did not, yielding 100% specificity in this study. A field trial was conducted in with both BengalScreen and Bengal DFA, and the results were compared with those obtained by conventional culture methods. BengalScreen demonstrated a sensitivity of 95%, a specificity of 100%, a positive predictive value of 100%, and a negative predictive value of 94%. Results obtained by Bengal DFA, on the other hand, were 100% sensitive and 100% specific and yielded 100% positive and negative predictive values compared with culture methods. In a second evaluation, 93 stool specimens from Mexico that were negative for V. cholerae O139 by culture were also tested with both the BengalScreen and Bengal DFA kits. None of the 93 specimens were positive for V. cholerae O139 by both tests. A concentration method was optimized for screening of environmental water samples for V. cholerae O139 synonym Bengal with rapid test kits. BengalScreen results were unequivocally positive when water samples contained at least 2.0 x 10(3) CFU/ml, whereas Bengal DFA demonstrated an unequivocally positive reaction when the water sample contained at least 1.5 x 10(2) CFU/ml. When Bengal DFA was compared with conventional culture methods for enumeration of V. cholerae O139 synonym Bengal organisms, no difference was observed.

  11. Evaluation of a rapid immunodiagnostic test kit for rabies virus.

    Science.gov (United States)

    Kang, BoKyu; Oh, JinSik; Lee, ChulSeung; Park, Bong-Kyun; Park, YoungNam; Hong, KyungSoo; Lee, KyungGi; Cho, ByungKi; Song, DaeSub

    2007-10-01

    A rapid immunodiagnostic test kit for rabies virus detection was evaluated using 51 clinical samples and 4 isolates of rabies virus. The quick detection of rabies virus under field conditions may be helpful in determining if post-exposure prophylaxis is needed, thereby avoiding unnecessary treatments, as well as undue economic burden. There are several widely used diagnostic methods for rabies, including fluorescent antibody tests, reverse transcription polymerase chain reaction, and electron microscopy; however, these methods include time-consuming, intricate, and costly procedures. The rapid immunodiagnostic test was able to detect rabies virus in clinical samples, including brain tissue and saliva, in addition to 10(3.2) 50% lethal dose (LD(50))/mL cell-adapted rabies virus. The assay was not cross-reactive with non-rabies virus microbes. When the performance of the rapid immunodiagnostic test was compared to a fluorescent antibody test, the rapid immunodiagnostic test had a sensitivity of 91.7% and specificity of 100% (95.8% CI).

  12. Modification of the Rappaport rapid test in large-scale testing for syphilis. Evaluation of the rapid plate and rapid card tests.

    Science.gov (United States)

    Ghinsberg, R; Meir, E; Blumstein, G; Kafeman, R

    1975-11-01

    The Rappaport rapid (RR) plate and card tests were developed as modifications of the RR tube test to permit rapid and inexpensive screening of large numbers of subjects for the diagnosis of syphilis. More than 2,000 sera were examined in parallel by the Venereal Disease Research Laboratory (VDRL) slide test, the rapid plasma reagin (RPR) card test and the RR plate and card tests. There was complete agreement between the RR plate and card tests and the VDRL slide and RPR card tests in 96.6% of sera. In a selected group of 1,530 sera examined, in addition, by the fluorescent treponemal antibody absorption (FTA-ABS) test, there was agreement between the RR plate and card tests and the FTA-ABS test in 74.3% of sera and between the VDRL and RPR tests and the FTA-ABS test in 73.7% of sera. The RR plate test was found to be sufficiently sensitive and specific for the diagnosis of syphilis, although the VDRL slide test is perhaps more sensitive in primary and late latent syphilis. Since the antigen used in the RR tests is colored and stable and the sera do not require inactivation before the test, the tests are easier to perform than the VDRL slide test: the RR plate and card tests could therefore replace the VDRL test as a screening test, with hardly any loss of accuracy.

  13. Evaluation of Gamma Interferon and Antibody Tuberculosis Tests in Alpacas

    Science.gov (United States)

    Holder, Tom; Clifford, Derek; Dexter, Ian; Brewer, Jacky; Smith, Noel; Waring, Laura; Crawshaw, Tim; Gillgan, Steve; Lyashchenko, Konstantin; Lawrence, John; Clarke, John; de la Rua-Domenech, Ricardo; Vordermeier, Martin

    2012-01-01

    We describe the performance of cell-based and antibody blood tests for the antemortem diagnosis of tuberculosis (TB) in South American camelids (SAC). The sensitivity and specificity of the gamma interferon (IFN-γ) release assay, two lateral flow rapid antibody tests (Stat-Pak and Dual Path Platform [DPP]), and two enzyme-linked immunosorbent assay (ELISA)-based antibody tests (Idexx and Enferplex) were determined using diseased alpacas from Mycobacterium bovis culture-confirmed breakdown herds and TB-free alpacas from geographical areas with no history of bovine TB, respectively. Our results show that while the sensitivities of the IFN-γ and antibody tests were similar (range of 57.7% to 66.7%), the specificity of the IFN-γ test (89.1%) was lower than those of any of the antibody tests (range of 96.4% to 97.4%). This lower specificity of the IFN-γ test was at least in part due to undisclosed Mycobacterium microti infection in the TB-free cohort, which stimulates a positive purified protein derivative (PPD) response. The sensitivity of infection detection could be increased by combining two antibody tests, but even the use of all four antibody tests failed to detect all diseased alpacas. These antibody-negative alpacas were IFN-γ positive. We found that the maximum sensitivity could be achieved only by the combination of the IFN-γ test with two antibody tests in a “test package,” although this resulted in decreased specificity. The data from this evaluation of tests with defined sensitivity and specificity provide potential options for antemortem screening of SAC for TB in herd breakdown situations and could also find application in movement testing and tracing investigations. PMID:22914362

  14. A new rapid immunohistochemical staining technique using the EnVision antibody complex.

    Science.gov (United States)

    Kämmerer, U; Kapp, M; Gassel, A M; Richter, T; Tank, C; Dietl, J; Ruck, P

    2001-05-01

    Rapid immunohistochemical investigation, in addition to staining with hematoxylin and eosin, would be useful during intraoperative frozen section diagnosis in some cases. This study was undertaken to investigate whether the recently described EnVision system, a highly sensitive two-step immunohistochemical technique, could be modified for rapid immunostaining of frozen sections. Forty-five primary antibodies were tested on frozen sections from various different tissues. After fixation in acetone for 1 min and air-drying, the sections were incubated for 3 min each with the primary antibody, the EnVision complex (a large number of secondary antibodies and horseradish peroxidase coupled to a dextran backbone), and the chromogen (3,3'diaminobenzidine or 3-amino-9-ethylcarbazole). All reactions were carried out at 37C. Specific staining was seen with 38 antibodies (including HMB-45 and antibodies against keratin, vimentin, leukocyte common antigen, smooth muscle actin, synaptophysin, CD34, CD3, CD20, and prostate-specific antigen). A modification of the EnVision method allows the detection of a broad spectrum of antigens in frozen sections in less than 13 min. This method could be a useful new tool in frozen section diagnosis and research. (J Histochem Cytochem 49:623-630, 2001)

  15. Evaluation of a New and Rapid Serologic Test for Detecting Brucellosis: Brucella Coombs Gel Test.

    Science.gov (United States)

    Hanci, Hayrunisa; Igan, Hakan; Uyanik, Muhammet Hamidullah

    2017-01-01

    Many serological tests have been used for the diagnosis of human brucellosis. A new serological method is identified as Brucella Coombs gel test based on the principle of centrifugation gel system similar to the gel system used in blood group determination. In this system, if Brucella antibodies were present in the serum, antigen and antibody would remain as a pink complex on the gel. Otherwise, the pink Brucella antigens would precipitate at the bottom of the gel card system. In this study, we aimed to compare the Brucella Coombs gel test, a new, rapid screen and titration method for detection of non-agglutinating IgG with the Brucella Coombs test. For this study, a total of 88 serum samples were obtained from 45 healthy persons and 43 individuals who had clinical signs and symptoms of brucellosis. For each specimen, Rose Bengal test, standard agglutination test, Coombs test and Brucella Coombs gel test were carried out. Sensitivity and specificity of Brucella Coombs gel test were found as 100.0 and 82.2%, respectively. Brucella Coombs gel test can be used as a screening test with high sensitivity. By the help of pink Brucella antigen precipitation, the tests' evaluation is simple and objective. In addition, determination of Brucella antibody by rapid titration offers another important advantage.

  16. Rapid identification of vibrio-cholerae O1 by coaglutination test using mono-specifis antibody

    Directory of Open Access Journals (Sweden)

    Bazargan SA

    1996-07-01

    Full Text Available In our investigation, rabbit hyper-immune serum to V.cholerae ogawa was absorbed with V.cholerae inaba whole-cells and vice versa. Applying ammonium sulphate precipitation method, mono-specific g globulins were purified and concentrated from the absorbed whole serum. These antibodies were fixed on staphylococcus cowan 1 NCTC-8325 whole-cells, using different chemical fixatives. It was observed that maximum fixation of g globulin to protein-A was achieved by 1-propanol 50% at 3 hours, which revealed through single radial immuno-diffusion techniqe. The rectal swab samples were cultured in an enrichment bile-peptons broth. After 5 hours 37°C while agitations, one drop of each sample was mixed with one drop of vibrio-cholerae bivalent mono-specific coagglutination reagent (VBCR. The results were read after 2 to 3 minutes. Finally though statistical analysis sensitivity and specificity of coagglutination test were calculated to be 95.1% and 99.2% respectively, when compared to positive & negative controls and conventional culture methods. Using VBCR, coagglutination test can be therefore considered as a simple, reliable and rapid method to detect V.cholerae O1 in the stool of patients in endemic area and less equipped laboratories

  17. Anti-insulin antibody test

    Science.gov (United States)

    Insulin antibodies - serum; Insulin Ab test; Insulin resistance - insulin antibodies; Diabetes - insulin antibodies ... Normally, there are no antibodies against insulin in your blood. ... different laboratories. Some labs use different measurements or ...

  18. Indirect micro-immunofluorescence test for detecting type-specific antibodies to herpes simplex virus.

    Science.gov (United States)

    Forsey, T; Darougar, S

    1980-02-01

    A rapid indirect micro-immunofluorescence test capable of detecting and differentiating type-specific antibodies to herpes simplex virus is described. The test proved highly sensitive and, in 80 patients with active herpes ocular infection, antibody was detected in 94%. No anti-herpes antibody was detected in a control group of 20 patients with adenovirus infections. Testing of animal sera prepared against herpes simplex virus types 1 and 2 and of human sera from cases of ocular and genital herpes infections showed that the test can differentiate antibodies to the infecting serotypes. Specimens of whole blood, taken by fingerprick, and eye secretions, both collected on cellulose sponges, could be tested by indirect micro-immunofluorescence. Anti-herpes IgG, IgM, and IgA can also be detected.

  19. Rapid T4 radioimmunoassay with antibody of Czechoslovak production

    Energy Technology Data Exchange (ETDEWEB)

    Cechacek, Z [MUNZ, Brno (Czechoslovakia) Div. of Nuclear Nedicine

    1978-06-30

    Rapid T4-RIA based on the T4-antibody produced in Institute of Experimental Endocrinology in Bratislava is described. The used T4-antibody was found as suitable preparation for the routine T4-RIA and is comparable to the foreign materials. T4 antibody was obtained by rabbit immunization and supplied as antiserum in a frozen state. It was properly diluted with 0.08M barbital buffer, pH 8.6, containing 0.a5% sodium ethylmercurythiosalicylate and 0.5% BSA.

  20. A rapid approach for characterization of thiol-conjugated antibody-drug conjugates and calculation of drug-antibody ratio by liquid chromatography mass spectrometry.

    Science.gov (United States)

    Firth, David; Bell, Leonard; Squires, Martin; Estdale, Sian; McKee, Colin

    2015-09-15

    We present the demonstration of a rapid "middle-up" liquid chromatography mass spectrometry (LC-MS)-based workflow for use in the characterization of thiol-conjugated maleimidocaproyl-monomethyl auristatin F (mcMMAF) and valine-citrulline-monomethyl auristatin E (vcMMAE) antibody-drug conjugates. Deconvoluted spectra were generated following a combination of deglycosylation, IdeS (immunoglobulin-degrading enzyme from Streptococcus pyogenes) digestion, and reduction steps that provide a visual representation of the product for rapid lot-to-lot comparison-a means to quickly assess the integrity of the antibody structure and the applied conjugation chemistry by mass. The relative abundance of the detected ions also offer information regarding differences in drug conjugation levels between samples, and the average drug-antibody ratio can be calculated. The approach requires little material (<100 μg) and, thus, is amenable to small-scale process development testing or as an early component of a complete characterization project facilitating informed decision making regarding which aspects of a molecule might need to be examined in more detail by orthogonal methodologies. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Evaluation of SD BIOLINE H. pylori Ag rapid test against double ELISA with SD H. pylori Ag ELISA and EZ-STEP H. pylori Ag ELISA tests.

    Science.gov (United States)

    Negash, Markos; Kassu, Afework; Amare, Bemnet; Yismaw, Gizachew; Moges, Beyene

    2018-01-01

    Helicobacter pylori antibody titters fall very slowly even after successful treatment. Therefore, tests detecting H. pylori antibody lack specificity and sensitivity. On the other hand, H. pylori stool antigen tests are reported as an alternative assay because of their reliability and simplicity. However, the comparative performance of H. pylori stool antigen tests for detecting the presence of the bacterium in clinical specimens in the study area is not assessed. Therefore, in this study we evaluated the performance of SD BIOLINE H. pylori Ag rapid test with reference to the commercially available EZ- STEP ELISA and SD BIOLINE H. pylori Ag ELISA tests. Stool samples were collected to analyse the diagnostic performance of SD BIOLINE H. pylori Ag rapid test kit using SD H. pylori Ag ELISA kit and EZ- STEP ELISA tests as a gold standard. Serum samples were also collected from each patient to test for the presence of H. pylori antibodies using dBest H. pylori Test Disk. Sensitivity, specificity, predictive values and kappa value are assessed. P values H. pylori Ag rapid test were: 95.6% (95% CI, 88.8-98.8), 92.5% (95%CI, 89-94.1%), 86.7% (95% CI, 80.5-89.6), and 97.6% (95% CI, 993.9-99.3) respectively. The performance of SD BIOLINE H. pylori Ag rapid test was better than the currently available antibody test in study area. Therefore, the SD BIOLINE Ag rapid stool test could replace and be used to diagnose active H. pylori infection before the commencement of therapy among dyspeptic patients.

  2. Evaluation of rapid HIV test kits on whole blood and development of rapid testing algorithm for voluntary testing and counseling centers in Ethiopia.

    Science.gov (United States)

    Tegbaru, Belete; Messele, Tsehaynesh; Wolday, Dawit; Meles, PhD Hailu; Tesema, Desalegn; Birhanu, Hiwot; Tesfaye, Girma; Bond, Kyle B; Martin, Robert; Rayfield, Mark A; Wuhib, Tadesse; Fekadu, Makonnen

    2004-10-01

    Five simple and rapid HIV antibody detection assays viz. Determine, Capillus, Oraquick, Unigold and Hemastrip were evaluated to examine their performance and to develop an alternative rapid test based testing algorithm for voluntary counseling and testing (VCT) in Ethiopia. All the kits were tested on whole blood, plasma and serum. The evaluation had three phases: Primary lab review, piloting at point of service and implementation. This report includes the results of the first two phases. A total of 2,693 specimens (both whole blood and plasma) were included in the evaluation. Results were compared to double Enzyme Linked Immuno-Sorbent Assay (ELISA) system. Discordant EIA results were resolved using Western Blot. The assays had very good sensitivities and specificities, 99-100%, at the two different phases of the evaluation. A 98-100% result agreement was obtained from those tested at VCT centers and National Referral Laboratory for AIDS (NRLA), in the quality control phase of the evaluation. A testing strategy yielding 100% [95% CI; 98.9-100.0] sensitivity was achieved by the sequential use of the three rapid test kits. Direct cost comparison showed serial testing algorithm reduces the cost of testing by over 30% compared to parallel testing in the current situation. Determine, Capillus/Oraquick (presence/absence of frefrigeration) and Unigold were recommended as screening, confirmation and tiebreaker tests, respectively.

  3. Rapid High-Level Production of Functional HIV Broadly Neutralizing Monoclonal Antibodies in Transient Plant Expression Systems

    Science.gov (United States)

    Rosenberg, Yvonne; Sack, Markus; Montefiori, David; Forthal, Donald; Mao, Lingjun; -Abanto, Segundo Hernandez; Urban, Lori; Landucci, Gary; Fischer, Rainer; Jiang, Xiaoming

    2013-01-01

    Passive immunotherapy using anti-HIV broadly neutralizing monoclonal antibodies (mAbs) has shown promise as an HIV treatment, reducing mother-to-child-transmission (MTCT) of simian/human immunodeficiency virus (SHIV) in non-human primates and decreasing viral rebound in patients who ceased receiving anti-viral drugs. In addition, a cocktail of potent mAbs may be useful as mucosal microbicides and provide an effective therapy for post-exposure prophylaxis. However, even highly neutralizing HIV mAbs used today may lose their effectiveness if resistance occurs, requiring the rapid production of new or engineered mAbs on an ongoing basis in order to counteract the viral resistance or the spread of a certain HIV-1 clade in a particular region or patient. Plant-based expression systems are fast, inexpensive and scalable and are becoming increasingly popular for the production of proteins and monoclonal antibodies. In the present study, Agrobacterium-mediated transient transfection of plants, utilizing two species of Nicotiana, have been tested to rapidly produce high levels of an HIV 89.6PΔ140env and several well-studied anti-HIV neutralizing monoclonal antibodies (b12, 2G12, 2F5, 4E10, m43, VRC01) or a single chain antibody construct (m9), for evaluation in cell-based viral inhibition assays. The protein-A purified plant-derived antibodies were intact, efficiently bound HIV envelope, and were equivalent to, or in one case better than, their counterparts produced in mammalian CHO or HEK-293 cells in both neutralization and antibody dependent viral inhibition assays. These data indicate that transient plant-based transient expression systems are very adaptable and could rapidly generate high levels of newly identified functional recombinant HIV neutralizing antibodies when required. In addition, they warrant detailed cost-benefit analysis of prolonged incubation in plants to further increase mAb production. PMID:23533588

  4. Rapid high-level production of functional HIV broadly neutralizing monoclonal antibodies in transient plant expression systems.

    Directory of Open Access Journals (Sweden)

    Yvonne Rosenberg

    Full Text Available Passive immunotherapy using anti-HIV broadly neutralizing monoclonal antibodies (mAbs has shown promise as an HIV treatment, reducing mother-to-child-transmission (MTCT of simian/human immunodeficiency virus (SHIV in non-human primates and decreasing viral rebound in patients who ceased receiving anti-viral drugs. In addition, a cocktail of potent mAbs may be useful as mucosal microbicides and provide an effective therapy for post-exposure prophylaxis. However, even highly neutralizing HIV mAbs used today may lose their effectiveness if resistance occurs, requiring the rapid production of new or engineered mAbs on an ongoing basis in order to counteract the viral resistance or the spread of a certain HIV-1 clade in a particular region or patient. Plant-based expression systems are fast, inexpensive and scalable and are becoming increasingly popular for the production of proteins and monoclonal antibodies. In the present study, Agrobacterium-mediated transient transfection of plants, utilizing two species of Nicotiana, have been tested to rapidly produce high levels of an HIV 89.6PΔ140env and several well-studied anti-HIV neutralizing monoclonal antibodies (b12, 2G12, 2F5, 4E10, m43, VRC01 or a single chain antibody construct (m9, for evaluation in cell-based viral inhibition assays. The protein-A purified plant-derived antibodies were intact, efficiently bound HIV envelope, and were equivalent to, or in one case better than, their counterparts produced in mammalian CHO or HEK-293 cells in both neutralization and antibody dependent viral inhibition assays. These data indicate that transient plant-based transient expression systems are very adaptable and could rapidly generate high levels of newly identified functional recombinant HIV neutralizing antibodies when required. In addition, they warrant detailed cost-benefit analysis of prolonged incubation in plants to further increase mAb production.

  5. Platelet antibodies blood test

    Science.gov (United States)

    This blood test shows if you have antibodies against platelets in your blood. Platelets are a part of the blood ... Chernecky CC, Berger BJ. Platelet antibody - blood. In: Chernecky ... caused by platelet destruction, hypersplenism, or hemodilution. ...

  6. Self-paired monoclonal antibody lateral flow immunoassay strip for rapid detection of Acidovorax avenae subsp. citrulli.

    Science.gov (United States)

    Zeng, Haijuan; Guo, Wenbo; Liang, Beibei; Li, Jianwu; Zhai, Xuzhao; Song, Chunmei; Zhao, Wenjun; Fan, Enguo; Liu, Qing

    2016-09-01

    We screened a highly specific monoclonal antibody (McAb), named 6D, against Acidovorax avenae subsp. citrulli (Aac). Single McAb 6D was used as both nanogold-labeled antibody and test antibody to develop a single self-paired colloidal gold immunochromatographic test strip (Sa-GICS). The detection limit achieved using the Sa-GICS approach was 10(5) CFU/mL, with a result that can be observed by the naked eye within 10 min. Moreover, Sa-GICS can detect eight strains of Aac and display no cross-reactions with other pathogenic plant microorganisms. Artificial contamination experiments demonstrated that Sa-GICS would not be affected by impurities in the leaves or stems of the plants and were consistent with the PCR results. This is the first report on the development of a colloidal gold immunoassay strip with self-paired single McAb for the rapid detection of Aac. Graphical Abstract Schematic representation of the test strip.

  7. Low specificity of 2 tetanus rapid tests in Cambodia.

    Science.gov (United States)

    Schlumberger, M; Yvonnet, B; Lesage, G; Tep, B

    2015-01-01

    Rapid testing for tetanus on serum or blood allows for an immediate evaluation of individual protection against tetanus in developed countries, using a "single step" immunochromatographic technique using tetanus toxoid. The specificity of these tests, compared to the reference method for tetanus, mouse serum neutralization testing, has however never been assessed in these countries, due to the difficulty to perform serum neutralization titration in mice, because of animal testing bioethical regulations. A collection of sera from adult volunteers in Cambodia, living in rural environment, was tested for tetanus antibodies by ELISA in France, and by mouse serum neutralization in Vietnam. This allowed estimating the sensitivity and specificity of 2 rapid tetanus tests, available on the market: TQS™ and Tetanotop™. The sensitivity of these tests was adequate, compared to mice serum neutralization test, for a test threshold of 0.01 IU/mL, (100% for TQS™, 91% for Tetanotop™), but their specificity was very low (1% for TQS™ and 13% for Tetanotop™). The results prove that these rapid tests for the assessment of individual protection against tetanus should not be used in the adult rural Cambodian population. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  8. 21 CFR 866.3290 - Gonococcal antibody test (GAT).

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Gonococcal antibody test (GAT). 866.3290 Section... antibody test (GAT). (a) Identification. A gonococcal antibody test (GAT) is an in vitro device that..., indirect fluorescent antibody, or radioimmunoassay, antibodies to Neisseria gonorrhoeae in sera of...

  9. Structural Changes in Stx1 Engineering Monoclonal Antibody Improves Its Functionality as Diagnostic Tool for a Rapid Latex Agglutination Test

    Directory of Open Access Journals (Sweden)

    Daniela Luz

    2018-02-01

    Full Text Available Stx1 toxin is one of the AB5 toxins of Shiga toxin-producing Escherichia coli (STEC responsible for foodborne intoxication during outbreaks. The single-chain variable fragment (scFv is the most common recombinant antibody format; it consists of both variable chains connected by a peptide linker with conserved specificity and affinity for antigen. The drawbacks of scFv production in bacteria are the heterologous expression, conformation and stability of the molecule, which could change the affinity for the antigen. In this work, we obtained a stable and functional scFv-Stx1 in bacteria, starting from IgG produced by hybridoma cells. After structural modifications, i.e., change in protein orientation, vector and linker, its solubility for expression in bacteria was increased as well as the affinity for its antigen, demonstrated by a scFv dissociation constant (KD of 2.26 × 10−7 M. Also, it was able to recognize purified Stx1 and cross-reacted with Stx2 toxin by ELISA (Enzyme-Linked Immunosorbent Assay, and detected 88% of Stx1-producing strains using a rapid latex agglutination test. Thus, the scFv fragment obtained in the present work is a bacteria-produced tool for use in a rapid diagnosis test, providing an alternative for STEC diagnosis.

  10. Evaluation of a direct immunofluorescent antibody (difma test using Leishmania genus - specific monoclonal antibody in the routine diagnosis of cutaneous leishmaniasis

    Directory of Open Access Journals (Sweden)

    Martha E. Chico

    1995-06-01

    Full Text Available A direct immunofluorescent antibody (DIFMA test using a Leishmania genus- specific monoclonal antibody was evaluated in the routine diagnosis of cutaneous leishmaniasis (CL in Ecuador. This test was compared with the standard diagnostic techniques of scrapings, culture and histology. Diagnostic samples were taken from a total of 90 active dermal ulcers from patients from areas of Ecuador known to be endemic for cutaneous leishmaniasis. DIFMA was positive in all lesions. It was shown to be significantly superior to standard diagnostic methods either alone or in combination. The sensitivity of DIFMA did not diminish with chronicity of lesions. This test proved to be extremely useful in the routine diagnosis of CL because it is highly sensitive, is easy to use and produces rapid results.

  11. Obtaining of a rapid diagnostic test for Cholera, based on latex particles coupled with a monoclonal antibody against Vibrio cholera O1 lipopolysaccharide

    Directory of Open Access Journals (Sweden)

    Fátima Reyes-López

    2015-08-01

    Full Text Available Cholera is an acute contagious intestinal disease caused by ingestion of food or water contaminated with O1 and O139 serotypes of the bacterium Vibrio cholerae. Cholera is characterized by abundant secretory diarrhea leading to dehydration. Death occurs within hours without treatment, so early diagnosis is very important, especially at the beginning of the disease, because it is difficult to differentiate from other acute diarrheal diseases. The diagnostic golden test is the stool culture; however, it does not guarantee a rapid detection of the disease. Rapid tests have been recently developed; they are based on test strips and agglutination with latex particles, which are very effective, but difficult to acquire for their high prices. The objective of this research was to obtain a quick assay based on latex particles coupled with a monoclonal antibody (mAb against V. cholerae O1 lipopolysaccharide obtained in Finlay Institute. Latex particles of 0.8 µm were used in a 10% suspension, and they were coupled to the mAb (0.25 mg/ml for 2 hours at 37°C. The sensitivity, specificity and performance were evaluated in 84 stool samples from patients with presumptive diagnosis of cholera. The diagnostic test obtained showed no cross-reactivity against no-O1 strains and other enteropathogens. Latex diagnostic test showed values of sensitivity, specificity and efficacy of 97.87; 97.29 and 97.6% respectively, very similar to the commercial diagnostic test CTK- Biotech. The latex reagent obtained can be used in the rapid diagnosis of the disease.

  12. Rapid enzyme-linked immunosorbent assay (ELISA) for Aspergillus fumigatus antibodies.

    OpenAIRE

    Richardson, M D; Stubbins, J M; Warnock, D W

    1982-01-01

    A rapid enzyme-linked immunosorbent assay (ELISA) where component incubation periods were shortened to one hour, was compared with agar gel double diffusion (AGDD) and a standard ELISA procedure for detecting antibodies to Aspergillus fumigatus in 28 asthmatic patients with suspected allergic aspergillosis. Using two A fumigatus antigens the rapid ELISA compared well with AGDD and the standard ELISA method. Eleven sera that reacted with both antigens in AGDD were all positive against antigen ...

  13. Rapid solid-phase radioimmunoassay for detection of equine infectious anemia viral antigen and antibodies: parameters involved in standardization

    International Nuclear Information System (INIS)

    Horenstein, A.L.; Feinstein, R.E.

    1985-01-01

    Solid-phase radioimmunoassays (SPRIA) are described for the detection of equine infectious anemia (EIA) viral antigen and antibodies. Protein-antigen P29 currently used in the agar-gel immunodiffusion (AGID) test was used as antigen in the SPRIA. The specificity of the reaction was assessed by inhibition with the antigen. The reaction of immune serum against EIA-virus antigen adsorbed to the wells, was completely inhibited by the antigen in solution. This property was applied in an indirect competitive SPRIA for the detection of viral protein P29. The detection threshold of the SPRIA for EIA virus protein was about 5 ng and about 1 ng of antibody can be detected. The assay is rapid, specific and sensitive and allows the testing of multiple serum samples with the advantage of employing a single secondary labelled antibody. (orig.)

  14. A Global Comparative Evaluation of Commercial Immunochromatographic Rapid Diagnostic Tests for Visceral Leishmaniasis

    NARCIS (Netherlands)

    Cunningham, Jane; Hasker, Epco; Das, Pradeep; El Safi, Sayda; Goto, Hiro; Mondal, Dinesh; Mbuchi, Margaret; Mukhtar, Maowia; Rabello, Ana; Rijal, Suman; Sundar, Shyam; Wasunna, Monique; Adams, Emily; Menten, Joris; Peeling, Rosanna; Boelaert, Marleen; Khanal, Basudha; Das, Murari; Oliveira, Edward; de Assis, Tália Machado; Costa, Dorcas Lamounier; Bhaskar, Khondaker Rifathassan; Huda, M. Mamun; Hassan, Mukidul; Abdoun, Asim Osman; Awad, Aymen; Osman, Mohamed; Prajapati, Dinesh Kumar; Gidwani, Kamlesh; Tiwary, Puja; Paniago, Anamaria Mello Miranda; Sanchez, Maria Carmen Arroyo; Celeste, Beatriz Julieta; Jacquet, Diane; Magiri, Charles; Muia, A.; Kesusu, J.; Ageed, Al Farazdag; Galal, Nuha; Osman, Osman Salih; Gupta, A. K.; Bimal, Afrad S.; Das, V. N. R.

    2012-01-01

    Background. Poor access to diagnosis stymies control of visceral leishmaniasis (VL). Antibody-detecting rapid diagnostic tests (RDTs) can be performed in peripheral health settings. However, there are many brands available and published reports of variable accuracy. Methods. Commercial VL RDTs

  15. Duration of antibody response following vaccination against feline immunodeficiency virus.

    Science.gov (United States)

    Westman, Mark E; Malik, Richard; Hall, Evelyn; Harris, Matthew; Hosie, Margaret J; Norris, Jacqueline M

    2017-10-01

    Objectives Recently, two point-of-care (PoC) feline immunodeficiency virus (FIV) antibody test kits (Witness and Anigen Rapid) were reported as being able to differentiate FIV-vaccinated from FIV-infected cats at a single time point, irrespective of the gap between testing and last vaccination (0-7 years). The aim of the current study was to investigate systematically anti-FIV antibody production over time in response to the recommended primary FIV vaccination series. Methods First, residual plasma from the original study was tested using a laboratory-based ELISA to determine whether negative results with PoC testing were due to reduced as opposed to absent antibodies to gp40. Second, a prospective study was performed using immunologically naive client-owned kittens and cats given a primary FIV vaccination series using a commercially available inactivated whole cell/inactivated whole virus vaccine (Fel-O-Vax FIV, three subcutaneous injections at 4 week intervals) and tested systematically (up to 11 times) over 6 months, using four commercially available PoC FIV antibody kits (SNAP FIV/FeLV Combo [detects antibodies to p15/p24], Witness FeLV/FIV [gp40], Anigen Rapid FIV/FeLV [p24/gp40] and VetScan FeLV/FIV Rapid [p24]). Results The laboratory-based ELISA showed cats from the original study vaccinated within the previous 0-15 months had detectable levels of antibodies to gp40, despite testing negative with two kits that use gp40 as a capture antigen (Witness and Anigen Rapid kits). The prospective study showed that antibody testing with SNAP Combo and VetScan Rapid was positive in all cats 2 weeks after the second primary FIV vaccination, and remained positive for the duration of the study (12/12 and 10/12 cats positive, respectively). Antibody testing with Witness and Anigen Rapid was also positive in a high proportion of cats 2 weeks after the second primary FIV vaccination (8/12 and 7/12, respectively), but antibody levels declined below the level of detection in

  16. Who accepts a rapid HIV antibody test? The role of race/ethnicity and HIV risk behavior among community adolescents.

    Science.gov (United States)

    Swenson, Rebecca R; Hadley, Wendy S; Houck, Christopher D; Dance, S Kwame; Brown, Larry K

    2011-05-01

    Centers for Disease Control and Prevention guidelines recommend routine human immunodeficiency virus (HIV) screening in health care settings for all individuals aged 13-64 years; however, overall testing rates among adolescents still continue to remain low. This study examined factors related to the acceptance of HIV testing among an at-risk sample of ethnically/racially diverse community adolescents. Adolescents aged 15-21 (N = 81) years were recruited from community-based youth organizations to complete HIV risk assessment surveys. After the completion of the survey, participants were offered a free OraQuick rapid HIV antibody test. More than half (53.1%) of the participants accepted the test, with the black population being more likely to accept testing as compared to Latinos (75% vs. 39%). After controlling for race/ethnicity, significant predictors of test acceptance included history of sexual intercourse (OR = 5.43), having only one sexual partner in the past 3 months (OR = 4.88), not always using a condom with a serious partner (OR = 3.94), and not using a condom during last sexual encounter (OR = 4.75). Given that many adolescents are willing to know their HIV status, policies that support free or low-cost routine testing may lead to higher rates of case identification among youth. However, approaches must be developed to increase test acceptance among Latino adolescents and teenagers with multiple sexual partners. Copyright © 2011 Society for Adolescent Health and Medicine. Published by Elsevier Inc. All rights reserved.

  17. Development of a rapid agglutination latex test for diagnosis of enteropathogenic and enterohemorrhagic Escherichia coli infection in developing world: defining the biomarker, antibody and method.

    Directory of Open Access Journals (Sweden)

    Letícia B Rocha

    2014-09-01

    Full Text Available Enteropathogenic and enterohemorrhagic Escherichia coli (EPEC/EHEC are human intestinal pathogens responsible for diarrhea in both developing and industrialized countries. In research laboratories, EPEC and EHEC are defined on the basis of their pathogenic features; nevertheless, their identification in routine laboratories is expensive and laborious. Therefore, the aim of the present work was to develop a rapid and simple assay for EPEC/EHEC detection. Accordingly, the EPEC/EHEC-secreted proteins EspA and EspB were chosen as target antigens.First, we investigated the ideal conditions for EspA/EspB production/secretion by ELISA in a collection of EPEC/EHEC strains after cultivating bacterial isolates in Dulbecco's modified Eagle's medium (DMEM or DMEM containing 1% tryptone or HEp-2 cells-preconditioned DMEM, employing either anti-EspA/anti-EspB polyclonal or monoclonal antibodies developed and characterized herein. Subsequently, a rapid agglutination latex test (RALT was developed and tested with the same collection of bacterial isolates.EspB was defined as a biomarker and its corresponding monoclonal antibody as the tool for EPEC/EHEC diagnosis; the production of EspB was better in DMEM medium. RALT assay has the sensitivity and specificity required for high-impact diagnosis of neglected diseases in the developing world.RALT assay described herein can be considered an alternative assay for diarrhea diagnosis in low-income countries since it achieved 97% sensitivity, 98% specificity and 97% efficiency.

  18. Evaluation of a rapid immunodiagnostic test kit for detection of African lyssaviruses from brain material

    Directory of Open Access Journals (Sweden)

    W. Markotter

    2009-09-01

    Full Text Available Rapid immunodiagnostic test kit was evaluated against a selection of isolates of lyssavirus genotypes occurring in Africa. The test was carried out in parallel comparison with the fluorescent antibody test (FAT and isolates representing previously established phylogenetic groups from each genotype were included. The specificity of the rapid immunodiagnostic test compared favourably with the FAT and was found to detect all representatives of genotypes 1, 2, 3 and 4 in brain samples of either field cases or suckling mouse brain inoculates.

  19. Antibody Blood Tests

    Science.gov (United States)

    ... out for sure? If antibody tests and/or symptoms suggest celiac disease, the physician needs to establish the diagnosis by ... who is still experiencing symptoms, to establish the diagnosis or to rule out celiac disease as a part of establishing another diagnosis. Find ...

  20. DARPA Antibody Technology Program. Standardized Test Bed for Antibody Characterization: Characterization of an MS2 ScFv Antibody Produced by Illumina

    Science.gov (United States)

    2016-08-01

    ECBC-TR-1395 DARPA ANTIBODY TECHNOLOGY PROGRAM STANDARDIZED TEST BED FOR... ANTIBODY CHARACTERIZATION: CHARACTERIZATION OF AN MS2 SCFV ANTIBODY PRODUCED BY ILLUMINA Patricia E. Buckley Alena M. Calm Heather Welsh Roy...4. TITLE AND SUBTITLE DARPA Antibody Technology Program Standardized Test Bed for Antibody Characterization: Characterization of an MS2 ScFv

  1. A Rapid Zika Diagnostic Assay to Measure Neutralizing Antibodies in Patients

    Directory of Open Access Journals (Sweden)

    Chao Shan

    2017-03-01

    Full Text Available The potential association of microcephaly and other congenital abnormalities with Zika virus (ZIKV infection during pregnancy underlines the critical need for a rapid and accurate diagnosis. Due to the short duration of ZIKV viremia in infected patients, a serologic assay that detects antibody responses to viral infection plays an essential role in diagnosing patient specimens. The current serologic diagnosis of ZIKV infection relies heavily on the labor-intensive Plaque Reduction Neutralization Test (PRNT that requires more than one-week turnaround time and represents a major bottleneck for patient diagnosis. To overcome this limitation, we have developed a high-throughput assay for ZIKV and dengue virus (DENV diagnosis that can attain the “gold standard” of the current PRNT assay. The new assay is homogeneous and utilizes luciferase viruses to quantify the neutralizing antibody titers in a 96-well format. Using 91 human specimens, we showed that the reporter diagnostic assay has a higher dynamic range and maintains the relative specificity of the traditional PRNT assay. Besides the improvement of assay throughput, the reporter virus technology has also shortened the turnaround time to less than two days. Collectively, our results suggest that, along with the viral RT-PCR assay, the reporter virus-based serologic assay could be potentially used as the first-line test for clinical diagnosis of ZIKV infection as well as for vaccine clinical trials.

  2. New monoclonal antibody-based test for Helicobacter pylori urease in gastric tissue.

    Science.gov (United States)

    Kim, Do Hyun; Kim, Ho Dong; Park, Hyeuk; Choi, Seung; Beom, Jae Won; Kim, Woo Jong; Park, Chang Kook; Lee, Young Jik; Park, Ju Young; Kim, Hyung Rag; Park, Chul; Joo, Young Eun; Jung, Young Do

    2016-01-01

    To evaluate a new monoclonal antibody for Helicobacter pylori urease in gastric tissue. A total of 107 volunteers were enrolled. All subjects underwent a (13)C-urea breath test and esophagogastroduodenoscopy. Gastric aspirates were analyzed for pH and ammonia. Six biopsy specimens in the gastric antrum and body were obtained for a rapid urease test and histology. The new monoclonal antibody-based H. pylori urease test (HPU) was performed to rapidly and qualitatively detect urease in two biopsy specimens. H. pylori infection was diagnosed in 73 subjects. The sensitivity and specificity of the HPU was 89% and 74%, respectively. The subjects were divided into two groups: one with true-positive and true-negative HPU results (n = 90) and the other with false-positive and false-negative HPU results (n = 17). Across all subjects, ammonia levels were 900.5 ± 646.7 and 604.3 ± 594.3 μmol/L (p > 0.05), and pH was 3.37 ± 1.64 and 2.82 ± 1.51 (p > 0.05). Sensitivity was higher in the presence of atrophic gastritis or intestinal metaplasia. HPU detected H. pylori in approximately 10 min. Gastric aspirate ammonia and pH levels did not affect the test results. Sensitivity was good in the presence of atrophic gastritis or intestinal metaplasia.

  3. Mobile Image Ratiometry: A New Method for Instantaneous Analysis of Rapid Test Strips

    OpenAIRE

    Donald C. Cooper; Bryan Callahan; Phil Callahan; Lee Burnett

    2012-01-01

    Here we describe Mobile Image Ratiometry (MIR), a new method for the automated quantification of standardized rapid immunoassay strips using consumer-based mobile smartphone and tablet cameras. To demonstrate MIR we developed a standardized method using rapid immunotest strips directed against cocaine (COC) and its major metabolite, benzoylecgonine (BE). We performed image analysis of three brands of commercially available dye-conjugated anti-COC/BE antibody test strips in response to three d...

  4. 21 CFR 866.5100 - Antinuclear antibody immunological test system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Antinuclear antibody immunological test system....5100 Antinuclear antibody immunological test system. (a) Identification. An antinuclear antibody... the autoimmune antibodies in serum, other body fluids, and tissues that react with cellular nuclear...

  5. Rapid production of antigen-specific monoclonal antibodies from a variety of animals

    Directory of Open Access Journals (Sweden)

    Kurosawa Nobuyuki

    2012-09-01

    Full Text Available Abstract Background Although a variety of animals have been used to produce polyclonal antibodies against antigens, the production of antigen-specific monoclonal antibodies from animals remains challenging. Results We propose a simple and rapid strategy to produce monoclonal antibodies from a variety of animals. By staining lymph node cells with an antibody against immunoglobulin and a fluorescent dye specific for the endoplasmic reticulum, plasma/plasmablast cells were identified without using a series of antibodies against lineage markers. By using a fluorescently labeled antigen as a tag for a complementary cell surface immunoglobulin, antigen-specific plasma/plasmablast cells were sorted from the rest of the cell population by fluorescence-activated cell sorting. Amplification of cognate pairs of immunoglobulin heavy and light chain genes followed by DNA transfection into 293FT cells resulted in the highly efficient production of antigen-specific monoclonal antibodies from a variety of immunized animals. Conclusions Our technology eliminates the need for both cell propagation and screening processes, offering a significant advantage over hybridoma and display strategies.

  6. A Highly Sensitive Rapid Diagnostic Test for Chagas Disease That Utilizes a Recombinant Trypanosoma cruzi Antigen

    Science.gov (United States)

    Barfield, C. A.; Barney, R. S.; Crudder, C. H.; Wilmoth, J. L.; Stevens, D. S.; Mora-Garcia, S.; Yanovsky, M. J.; Weigl, B. H.; Yanovsky, J.

    2011-01-01

    Improved diagnostic tests for Chagas disease are urgently needed. A new lateral flow rapid test for Chagas disease is under development at PATH, in collaboration with Laboratorio Lemos of Argentina, which utilizes a recombinant antigen for detection of antibodies to Trypanosoma cruzi. To evaluate the performance of this test, 375 earlier characterized serum specimens from a region where Chagas is endemic were tested using a reference test (the Ortho T. cruzi ELISA, Johnson & Johnson), a commercially available rapid test (Chagas STAT-PAK, Chembio), and the PATH–Lemos rapid test. Compared to the composite reference tests, the PATH–Lemos rapid test demonstrated an optimal sensitivity of 99.5% and specificity of 96.8%, while the Chagas STAT-PAK demonstrated a sensitivity of 95.3% and specificity of 99.5%. These results indicate that the PATH–Lemos rapid test shows promise as an improved and reliable tool for screening and diagnosis of Chagas disease. PMID:21342808

  7. Diagnosis of acute mononucleosis in emergency: comparison of rapid tests

    Directory of Open Access Journals (Sweden)

    Federica Scaggiante

    2011-09-01

    Full Text Available Epstein-Barr virus (EBV is a gammaherpesvirus that causes a number of clinical syndromes, including acute mononucleosis.Acute infection with EBV can vary widely with regard to the severity and presentation of illness, ranging from an asymptomatic infection to a serious, life-threatening version of mononucleosis with associated liver damage and splenomegaly. Additionally, other acute viral syndromes, including those caused by hepatitis viruses and cytomegalovirus (CMV, can lead to similar clinical syndromes. The variety of symptoms and the overlap with other viral infections underscore the importance of laboratory testing in the diagnosis of acute EBV-related disease.The purpose of this study was to evaluate the utility of an agglutination test for the detection of heterophile antibodies (Monotest and two EBV-specific rapid immunochromatographic tests (VCA-IgM and VCA-IgG/EBNA-IgG. Heterophile antibody determination is resulted to have not a real diagnostic utility for the low sensibility and specificity of the test. In our experience the only use of VCA-IgG/EBNA-IgG test is sufficient to discriminate between an acute mononucleosis and a past infection.

  8. Rapid isolation of antibody from a synthetic human antibody library by repeated fluorescence-activated cell sorting (FACS.

    Directory of Open Access Journals (Sweden)

    Sung Sun Yim

    Full Text Available Antibodies and their derivatives are the most important agents in therapeutics and diagnostics. Even after the significant progress in the technology for antibody screening from huge libraries, it takes a long time to isolate an antibody, which prevents a prompt action against the spread of a disease. Here, we report a new strategy for isolating desired antibodies from a combinatorial library in one day by repeated fluorescence-activated cell sorting (FACS. First, we constructed a library of synthetic human antibody in which single-chain variable fragment (scFv was expressed in the periplasm of Escherichia coli. After labeling the cells with fluorescent antigen probes, the highly fluorescent cells were sorted by using a high-speed cell sorter, and these cells were reused without regeneration in the next round of sorting. After repeating this sorting, the positive clones were completely enriched in several hours. Thus, we screened the library against three viral antigens, including the H1N1 influenza virus, Hepatitis B virus, and Foot-and-mouth disease virus. Finally, the potential antibody candidates, which show K(D values between 10 and 100 nM against the target antigens, could be successfully isolated even though the library was relatively small (∼ 10(6. These results show that repeated FACS screening without regeneration of the sorted cells can be a powerful method when a rapid response to a spreading disease is required.

  9. Evaluation of Blood-Based Antibody Rapid Testing for HIV Early Therapy: A Meta-Analysis of the Evidence

    Directory of Open Access Journals (Sweden)

    Xiaojie Huang

    2018-06-01

    Full Text Available BackgroundWestern blot (WB assay is considered the gold standard test for HIV infection confirmation. However, it requires technical expertise and is quite time-consuming. WHO recommends blood-based rapid diagnosis to achieve same-day test and treatment. However, this rapid testing strategy has not been promoted worldwide due to inadequate research evaluating the effectiveness of rapid tests (RTs as an alternative confirmatory HIV test for WB. This study aims to compare the diagnostic performance of rapid HIV tests compared with WB.MethodsPubMed and Web of Science were searched for publications on rapid HIV tests using blood specimen. A meta-analysis was performed to quantitatively evaluate the diagnostic performance of rapid HIV tests compared with the WB assay in terms of pooled sensitivity, specificity, area under summary receiver operating characteristic (SROC curve, and diagnostic odds ratio (DOR.ResultsTwenty articles involving 27,343 fresh specimens for rapid HIV tests were included in the meta-analysis. Regarding Capillus HIV-1/HIV-2, the pooled sensitivity, specificity, area under SROC curve, and DOR derived from six studies were 0.999 (95% CI, 0.956–1.000, 0.999 (95% CI, 0.991–1.00, 1.00 (95% CI, 0.99–1.00, and 1.0 × 106 (95% CI, 2.6 × 104–3.9 × 107 compared with the WB assay, respectively. With respect to Determine HIV-1/2, the pooled sensitivity, specificity area under SROC, and DOR derived from eight studies were 1.00 (95% CI, 0.789–1.000, 0.992 (95% CI, 0.985–0.996, 1.00 (95% CI, 0.99–1.00, and 1.8 × 106 (95% CI 406.049–7.8 × 109 compared with the WB assay, respectively. Regarding two-step serial RTs, the pooled sensitivity, specificity area under SROC, and DOR derived from eight studies were 0.998 (95% CI, 0.991–1.000, 0.998 (95% CI, 0.994–0.999, and 1.00 (95% CI 0.99–1.00 compared with the WB assay, respectively.ConclusionOur meta-analysis results may provide evidenced-based support

  10. Rapid and quantitative detection of C-reactive protein using quantum dots and immunochromatographic test strips

    Directory of Open Access Journals (Sweden)

    Cheng X

    2014-12-01

    Full Text Available Xianglin Cheng,1,* Xu Pu,2,* Pen Jun,3 XiaoBo Zhu,3 Di Zhu,4 Ming Chen1 1Department of Laboratory Medicine, First Affiliated Hospital of Yangtze University, Jingzhou, 2Department of Laboratory Medicine, RenMin Hospital of Wuhan University, Wuhan, 3Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education, College of Chemistry and Molecular Sciences, Wuhan University, Wuhan, Hubei, People’s Republic of China; 4Department of Medical Oncology, Dana-Farber Cancer Institute, Harvard Medical School, Boston, MA, USA *These authors contributed equally to this study and share first authorship Background: Rapid immunochromatographic tests can detect disease markers in 10–15 minutes, which facilitates clinical diagnosis and treatment programs. However, most immunochromatographic tests employ gold nanoparticles as reporters, and these have only moderate sensitivity and act as qualitative methods for analyzing high biomarker concentrations. Methods: In this study, we introduce quantum dots (QDs as fluorescent probes and immunochromatographic strips to develop quantitative fluorescence point-of-care tests (QF-POCT to analyze C-reactive protein (CRP levels. Goat anti-rabbit IgG and rabbit IgG were used as control antibodies, and mouse monoclonal CRP antibody pairs were used for disease marker detection. One monoclonal CRP antibody was conjugated with QDs and served as a signal antibody, and the other monoclonal CRP antibody was dispensed onto the nitrocellulose membrane and served as a capturing antibody. In the presence of CRP, the fluorescence intensity of the monoclonal antibody-CRP-monoclonal antibody sandwich complex captured on the nitrocellulose membrane was determined using the fluorescence strip reader. Results: QF-POCT assays could quantitatively analyze the concentration of CRP in 15 minutes had a detection limit of 0.25 mg/L, and had a wide detection linearity range (0.5–300 mg/L. The intra-assay and interassay

  11. Comparative Evaluation of Seven Commercial Tests for Detection of Heterophile Antibody in Infectious Mononucleosis

    Directory of Open Access Journals (Sweden)

    Martin Skulnick

    1992-01-01

    Full Text Available Detection of heterophile antibodies in infectious mononucleosis is the most rapid and cost-effective method for confirming the clinical diagnosis of the disease. This study compared seven commercial test kits (the Oxoid Infectious Mononucleosis Kit [Oxoid Ltd], Immunoscan Im-Latex [Baxter Travenol], Mono-Latex [Wampole Laboratories], Monospot and Im Screen Test [Ortho Diagnostics], Immunoscan Im-RBC Test [Baxter Travenol], and Infectious Mononucleosis Test [NCS Diagnostics] to the Davidsohn differential test. All of the kits were shown to be acceptable for use, with specificities and sensitivities greater than 96.5% and 95.5%, respectively.

  12. Non-reactive HIV-1 Rapid Tests after Sustained Viral Suppression Following Antiretroviral Therapy Initiation During Primary Infection.

    Science.gov (United States)

    Stefic, Karl; Novelli, Sophie; Mahjoub, Nadia; Seng, Remonie; Molina, Jean-Michel; Cheneau, Christine; Barin, Francis; Chaix, Marie-Laure; Meyer, Laurence; Delaugerre, Constance

    2018-03-02

    We assessed the impact of early antiretroviral treatment (ART) on HIV antibody detection by rapid tests in 44 individuals after several years of successful ART. HIV self-tests and point-of-care tests were negative in respectively 30% and 7-9% of cases. These data reinforce the message that patients should never be retested after entering HIV care.

  13. Utility of HLA Antibody Testing in Kidney Transplantation

    Science.gov (United States)

    Konvalinka, Ana

    2015-01-01

    HLA antigens are polymorphic proteins expressed on donor kidney allograft endothelium and are critical targets for recipient immune recognition. HLA antibodies are risk factors for acute and chronic rejection and allograft loss. Solid-phase immunoassays for HLA antibody detection represent a major advance in sensitivity and specificity over cell-based methods and are widely used in organ allocation and pretransplant risk assessment. Post-transplant, development of de novo donor–specific HLA antibodies and/or increase in donor-specific antibodies from pretransplant levels are associated with adverse outcomes. Although single antigen bead assays have allowed sensitive detection of recipient HLA antibodies and their specificities, a number of interpretive considerations must be appreciated to understand test results in clinical and research contexts. This review, which is especially relevant for clinicians caring for transplant patients, discusses the technical aspects of single antigen bead assays, emphasizes their quantitative limitations, and explores the utility of HLA antibody testing in identifying and managing important pre- and post-transplant clinical outcomes. PMID:25804279

  14. Evaluation of an Immunochromatographic Test for Rapid and Reliable Serodiagnosis of Human Tularemia and Detection of Francisella tularensis-Specific Antibodies in Sera from Different Mammalian Species ▿

    Science.gov (United States)

    Splettstoesser, W.; Guglielmo-Viret, V.; Seibold, E.; Thullier, P.

    2010-01-01

    Tularemia is a highly contagious infectious zoonosis caused by the bacterial agent Francisella tularensis. Serology is still considered to be a cornerstone in tularemia diagnosis due to the low sensitivity of bacterial culture and the lack of standardization in PCR methodology for the direct identification of the pathogen. We developed a novel immunochromatographic test (ICT) to efficiently detect F. tularensis-specific antibodies in sera from humans and other mammalian species (nonhuman primate, pig, and rabbit). This new tool requires none or minimal laboratory equipment, and the results are obtained within 15 min. When compared to the method of microagglutination, which was shown to be more specific than the enzyme-linked immunosorbent assay, the ICT had a sensitivity of 98.3% (58 positive sera were tested) and a specificity of 96.5% (58 negative sera were tested) on human sera. On animal sera, the overall sensitivity was 100% (22 positive sera were tested) and specificity was also 100% (70 negative sera were tested). This rapid test preferentially detects IgG antibodies that may occur early in the course of human tularemia, but further evaluation with human sera is important to prove that the ICT can be a valuable field test to support a presumptive diagnosis of tularemia. The ICT can also be a useful tool to monitor successful vaccination with subunit vaccines or live vaccine strains containing lipopolysaccharide (e.g., LVS) and to detect seropositive individuals or animals in outbreak situations or in the context of epidemiologic surveillance programs in areas of endemicity as recently recommended by the World Health Organization. PMID:20220165

  15. ANA (Antinuclear Antibody Test)

    Science.gov (United States)

    ... as ratios. For example, the result 1:320 means that one part blood sample was mixed with 320 parts of a diluting ... name "antinuclear". My doctor told me my ANA test is ... normal concentration of these antibodies. This is one of the tools in diagnosing lupus as well ...

  16. Rapid identification of HPV 16 and 18 by multiplex nested PCR-immunochromatographic test.

    Science.gov (United States)

    Kuo, Yung-Bin; Li, Yi-Shuan; Chan, Err-Cheng

    2015-02-01

    Human papillomavirus (HPV) types 16 and 18 are known to be high-risk viruses that cause cervical cancer. An HPV rapid testing kit that could help physicians to make early and more informed decisions regarding patient care is needed urgently but not yet available. This study aimed to develop a multiplex nested polymerase chain reaction-immunochromatographic test (PCR-ICT) for the rapid identification of HPV 16 and 18. A multiplex nested PCR was constructed to amplify the HPV 16 and 18 genotype-specific L1 gene fragments and followed by ICT which coated with antibodies to identify rapidly the different PCR products. The type-specific gene regions of high-risk HPV 16 and 18 could be amplified successfully by multiplex nested PCR at molecular sizes of approximately 99 and 101bp, respectively. The capture antibodies raised specifically against the moleculars labeled on the PCR products could be detected simultaneously both HPV 16 and 18 in one strip. Under optimal conditions, this PCR-ICT assay had the capability to detect HPV in a sample with as low as 100 copies of HPV viral DNA. The PCR-ICT system has the advantage of direct and simultaneous detection of two high-risk HPV 16 and 18 DNA targets in one sample, which suggested a significant potential of this assay for clinical application. Copyright © 2014. Published by Elsevier B.V.

  17. Rapid preparative separation of monoclonal antibody charge variants using laterally-fed membrane chromatography.

    Science.gov (United States)

    Sadavarte, Rahul; Madadkar, Pedram; Filipe, Carlos Dm; Ghosh, Raja

    2018-01-15

    Monoclonal antibodies undergo various forms of chemical transformation which have been shown to cause loss in efficacy and alteration in pharmacokinetic properties of these molecules. Such modified antibody molecules are known as variants. They also display physical properties such as charge that are different from intact antibody molecules. However, the difference in charge is very subtle and separation based on it is quite challenging. Charge variants are usually separated using ion-exchange column chromatography or isoelectric focusing. In this paper, we report a rapid and scalable method for fractionating monoclonal antibody charge variants, based on the use of cation exchange laterally-fed membrane chromatography (LFMC). Starting with a sample of monoclonal antibody hIgG1-CD4, three well-resolved fractions were obtained using either pH or salt gradient. These fractions were identified as acidic, neutral and basic variants. Each of these fractions contained intact heavy and light chains and so antibody fragmentation had no role in variant generation. The separation was comparable to that using column chromatography but was an order of magnitude faster. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Rapid detection of fumonisin B1 using a colloidal gold immunoassay strip test in corn samples.

    Science.gov (United States)

    Ling, Sumei; Wang, Rongzhi; Gu, Xiaosong; Wen, Can; Chen, Lingling; Chen, Zhibin; Chen, Qing-Ai; Xiao, Shiwei; Yang, Yanling; Zhuang, Zhenhong; Wang, Shihua

    2015-12-15

    Fumonisin B1 (FB1) is the most common and highest toxic of fumonisins species, exists frequently in corn and corn-based foods, leading to several animal and human diseases. Furthermore, FB1 was reported that it was associated with the human esophageal cancer. In view of the harmful of FB1, it is urgent to develop a feasible and accuracy method for rapid detection of FB1. In this study, a competitive immunoassay for FB1 detection was developed based on colloidal gold-antibody conjugate. The FB1-keyhole limpet hemoeyanin (FB1-KLH) conjugate was embedded in the test line, and goat anti-mouse IgG antibody embedded in the control line. The color density of the test line correlated with the concentration of FB1 in the range from 2.5 to 10 ng/mL, and the visual limit detection of test for FB1 was 2.5 ng/mL. The results indicated that the test strip is specific for FB1, and no cross-reactivity to other toxins. The quantitative detection for FB1 was simple, only needing one step without complicated assay performance and expensive equipment, and the total time of visual evaluation was less than 5 min. Hence, the developed colloidal gold-antibody assay can be used as a feasible method for FB1 rapid and quantitative detection in corn samples. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Brief Report: Impact of Early Antiretroviral Therapy on the Performance of HIV Rapid Tests and HIV Incidence Assays.

    Science.gov (United States)

    Fogel, Jessica M; Piwowar-Manning, Estelle; Debevec, Barbara; Walsky, Tamara; Schlusser, Katherine; Laeyendecker, Oliver; Wilson, Ethan A; McCauley, Marybeth; Gamble, Theresa; Tegha, Gerald; Soko, Dean; Kumwenda, Johnstone; Hosseinipour, Mina C; Chen, Ying Q; Cohen, Myron S; Eshleman, Susan H

    2017-08-01

    Antiretroviral therapy (ART) can downregulate antibody responses to HIV infection. We evaluated the impact of early vs. delayed ART on the performance of HIV diagnostic and incidence assays. Samples were obtained from 207 participants in the HPTN 052 trial, who were stably suppressed on ART for ≥4 years [Malawi sites; pre-ART CD4 cell count 350-550 cells/mm (early ART arm, N = 180) or ART arm, N = 27)]. Samples were tested with 2 HIV rapid tests and 2 HIV incidence assays; selected samples were also tested with two fourth-generation immunoassays and a Western blot (WB) assay. A pre-ART sample was analyzed if the follow-up sample had a false-negative or weakly-reactive rapid test result, or had an incidence assay result indicative of recent infection (false-recent result). Ten (4.8%) samples had a nonreactive or weakly-reactive rapid test result (7/180 early ART arm, 3/27 delayed ART arm, P = 0.13); one sample had nonreactive fourth-generation assay results and 3 had indeterminate WBs. Forty (18.9%) samples had a false-recent incidence assay result; 16 (7.8%) had false-recent results with both incidence assays. Baseline samples had stronger rapid test and WB bands, higher fourth-generation assay signal-to-cutoff values, and fewer HIV incidence assay results indicative of recent infection. False-negative/weakly-reactive HIV rapid tests and false-recent HIV incidence assay results were observed in virally-suppressed individuals, regardless of pre-ART CD4 cell count. Downregulation of the antibody response to HIV infection in the setting of ART may impact population-level surveys of HIV prevalence and incidence.

  20. A Rapid Detection Method of Brucella with Quantum Dots and Magnetic Beads Conjugated with Different Polyclonal Antibodies

    Science.gov (United States)

    Song, Dandan; Qu, Xiaofeng; Liu, Yushen; Li, Li; Yin, Dehui; Li, Juan; Xu, Kun; Xie, Renguo; Zhai, Yue; Zhang, Huiwen; Bao, Hao; Zhao, Chao; Wang, Juan; Song, Xiuling; Song, Wenzhi

    2017-03-01

    Brucella spp. are facultative intracellular bacteria that cause zoonotic disease of brucellosis worldwide. Traditional methods for detection of Brucella spp. take 48-72 h that does not meet the need of rapid detection. Herein, a new rapid detection method of Brucella was developed based on polyclonal antibody-conjugating quantum dots and antibody-modified magnetic beads. First, polyclonal antibodies IgG and IgY were prepared and then the antibody conjugated with quantum dots (QDs) and immunomagnetic beads (IMB), respectively, which were activated by N-(3-dimethylaminopropyl)- N'-ethylcar-bodiimide hydrochloride (EDC) and N-hydroxysuccinimide (NHS) to form probes. We used the IMB probe to separate the Brucella and labeled by the QD probe, and then detected the fluorescence intensity with a fluorescence spectrometer. The detection method takes 105 min with a limit of detection of 103 CFU/mL and ranges from 10 to 105 CFU/mL ( R 2 = 0.9983), and it can be well used in real samples.

  1. A standard screening test for the early and rapid diagnosis of leptospirosis

    Directory of Open Access Journals (Sweden)

    Chandrasekaran S

    2004-01-01

    Full Text Available PURPOSE : To perform dark field microscopy (DFM for detection of Leptospira and to validate the results using Leptospira IgM antibody SERION ELISA test. METHODS : After differential centrifugation of Ruys, DFM was done to demonstrate Leptospira in the blood and SERION ELISA was done for Leptospira IgM antibody in single or paired serum samples. One hundred and eleven cases (39 adults and 72 children of suspected leptospirosis were included in the study. RESULTS : Anicteric cases accounted for 66.7% (26/39 of adults and complications involving brain, liver, kidney and eyes were seen in 33.3% (13/39. In children, 90.3% (65/72 were anicteric and involvement of brain and liver was seen in 9.7% (7/72 cases. On testing 60 single samples of blood from 23 adults and 37 children, DFM exhibited greater sensitivity of 93.3% (56/60 than that of SERION ELISA for Leptospira IgM antibody (33.3%, 20/60. It was observed that the positivity of DFM decreased from 100% (15/15 to 90.9% (10/11 with increase in the duration of infection for more than one week. ELISA for Leptospira IgM, done on 51 paired blood samples, was positive in 64.7% (33/51 cases when both (first and second samples were tested while in 45.1% (23/51 cases was positive with first sample alone. 58.8%(30/51 cases were positive by testing second sample. DFM results on paired blood samples showed persistence of Leptospira in 92.9% of cases. CONCLUSION : This study shows the validation of DFM results by SERION ELISA for Leptospira IgM antibody, based on which we recommend that DFM can serve as a standard screening test for early and rapid diagnosis of leptospirosis.

  2. Cross-sectional study of serum antibodies against Sarcocystis neurona in cats tested for antibodies against Toxoplasma gondii.

    Science.gov (United States)

    Rossano, Mary G; Murphy, Alice J; Vrable, Ruth A; Vanzo, Nicole E; Lewis, Stacy K; Sheline, Katherine D; Kaneene, John B; Mansfield, Linda S

    2002-08-15

    To determine apparent seroprevalence of antibodies against Sarcocystis neurona in a population of domestic cats previously tested for antibodies against Toxoplasma gondii. Cross-sectional study. Serum from 196 domestic cats. Banked serum samples submitted to the Michigan State University Animal Health Diagnostic Laboratory for T. gondii diagnostic testing were tested for antibodies against S. neurona by use of an indirect fluorescent antibody (IFA) test and a western blot test. Submission records were analyzed to determine descriptive statistics and test for associations between positive results of a test for S. neurona and other variables in the data set. 10 of 196 (5%) samples yielded positive results for antibodies against S. neurona by use of western blot analysis, whereas 27 samples yielded positive results by use of the IFA. No association was found between S. neurona western blot test results and T. gondii test results, age, sex, or the reason for T. gondii testing. The S. neurona IFA titer was positively and significantly associated with positive results of western blot analysis. Domestic cats are not likely to play a substantial role as intermediate hosts in the natural life cycle of S. neurona. Results indicate that natural infection of domestic cats may occur, and small animal practitioners should be aware of this fact when evaluating cats with neurologic disease. The S. neurona IFA test had lower specificity than western blot analysis.

  3. Development and evaluation of an immunochromatographic strip test based on the recombinant UL51 protein for detecting antibody against duck enteritis virus

    Directory of Open Access Journals (Sweden)

    Sun Tao

    2010-10-01

    Full Text Available Abstract Background Duck enteritis virus (DEV infection causes substantial economic losses to the worldwide duck-producing areas. The monitoring of DEV-specific antibodies is a key to evaluate the effect of DEV vaccine and develop rational immunization programs. Thus, in this study, an immunochromatographic strip (ICS test was developed for detecting DEV serum antibodies. Results The ICS test is based on membrane chromatography, and uses both the purified recombinant UL51 protein conjugated with colloidal gold and goat anti-rabbit IgG conjugated with colloidal gold as tracers, the purified recombinant UL51 protein as the capture reagent at the test line, and rabbit IgG as the capture reagent at the control line. The specificity of the ICS was evaluated by sera against DEV, Duck hepatitis virus (DHV, Riemerella anatipestifer (RA, Duck E. coli, Muscovy duck parvovirus (MPV, or Duck Influenza viruses (DIV. Only sera against DEV showed the strong positive results. In order to determine the sensitivity of the ICS, anti-DEV serum diluted serially was tested, and the minimum detection limit of 1:128 was obtained. The ICS components, which are provided in a sealed package, require no refrigeration and are stable for 12 months. To evaluate the effect of the ICS, 110 duck serum samples collected from several non-immune duck flocks were simultaneously tested by the ICS test, enzyme-linked immunosorbent assay (ELISA and neutralization test (NT. The results showed that the sensitivity of the ICS test was almost consistent with ELISA and much higher than NT, has low cost, and is rapid (15 min and easy to perform with no requirement of specialized equipment, reagent or technicians. Conclusions In this work, we successfully developed a simple and rapid ICS test for detecting DEV serum antibodies for the first time. The ICS test was high specific and sensitive for the rapid detection of anti-DEV antibodies, and has great potential to be used for the serological

  4. Antiparietal cell antibody test

    Science.gov (United States)

    APCA; Anti-gastric parietal cell antibody; Atrophic gastritis - anti-gastric parietal cell antibody; Gastric ulcer - anti-gastric parietal cell antibody; Pernicious anemia - anti-gastric parietal cell antibody; ...

  5. Heterophilic antibodies interfering with radioimmunoassay. A false-positive pregnancy test

    Energy Technology Data Exchange (ETDEWEB)

    Vladutiu, A.O.; Sulewski, J.M.; Pudlak, K.A.; Stull, C.G.

    1982-11-19

    A young woman with amenorrhea had a consistently positive pregnancy test result (serum radioimmunoassay measurement of ..beta..-human chorionic gonadotropin hormone). No fetal or placental tissue was found after uterine curettage and exploratory laparotomy. The false-positive pregnancy test result was due to heterophilic antibovine and antigoat antibodies in the patient's serum. These antibodies interfered with radioimmunoassays using goat antibodies. This case shows that serum heterophilic antibodies can interfere with immunoassays and result in unnecessary diagnostic procedures and/or unnecessary treatment.

  6. Heterophilic antibodies interfering with radioimmunoassay. A false-positive pregnancy test

    International Nuclear Information System (INIS)

    Vladutiu, A.O.; Sulewski, J.M.; Pudlak, K.A.; Stull, C.G.

    1982-01-01

    A young woman with amenorrhea had a consistently positive pregnancy test result (serum radioimmunoassay measurement of #betta#-human chorionic gonadotropin hormone). No fetal or placental tissue was found after uterine curettage and exploratory laparotomy. The false-positive pregnancy test result was due to heterophilic antibovine and antigoat antibodies in the patient's serum. These antibodies interfered with radioimmunoassays using goat antibodies. This case shows that serum heterophilic antibodies can interfere with immunoassays and result in unnecessary diagnostic procedures and/or unnecessary treatment

  7. Development of a immunochromatographic test with avidin-biotin for the detection of antibodies against antigen e of hepatitis B in human plasma

    International Nuclear Information System (INIS)

    Mainet Gonzalez, Damian; Palenzuela Gardon, Daniel O; Diaz Argudin, Tamara

    2007-01-01

    The disappearance of antigen e of hepatitis B in the presence of the plasmatic antibodies against antigen e may indicate a satisfactory therapeutic response in patients with chronic hepatitis B. The immuno-chromatographic test carried out in the diagnosis of diseases use different antibody combinations and may employ the avidin or streptavidin-biotin technology to develop a rapid immuno-chromatographic test for the detection of antibodies anti-antigen e in the plasma. They were detected in the laboratory by means of two fast immuno-chromatographic tests when using in one of them the avidin-biotin technology. These tests are carried out with a one-step competitive inhibition format and amplified or not with avidin-biotin. Monoclonal antibodies against antigen e obtained by cellular hybridization were used. Forty-six plasmatic samples classified as positive and negative to the anti-antigen antibodies were evaluated with a reference immunochromatographic test Advanced QualityTM. The possible expiry time of the biological reagents forming part of these tests were studied with accelerated thermal-stability experiments. The possible interference in the plasma of some of the biochemical compounds used in these trials was analyzed. Four murine monoclonal antibodies anti-antigen e were obtained and only one of them was used in these immunochromatographic tests with an anti-antigen polyclonal antibody conjugated with gold. Both tests and their stable biological reagents discriminated the positive and negative samples to the antibodies anti-antigen e, as well as the commercial test. There was no interference in the biochemical compounds studied in these tests. Both immuno-chromatographic tests made in the laboratory are useful to detect antibodies anti-antigen e in the plasma. The avidin-biotin increased the analytical sensitivity of this type of fast immuno-chromatographic test without altering its performance features. (Author)

  8. An automated robotic platform for rapid profiling oligosaccharide analysis of monoclonal antibodies directly from cell culture.

    Science.gov (United States)

    Doherty, Margaret; Bones, Jonathan; McLoughlin, Niaobh; Telford, Jayne E; Harmon, Bryan; DeFelippis, Michael R; Rudd, Pauline M

    2013-11-01

    Oligosaccharides attached to Asn297 in each of the CH2 domains of monoclonal antibodies play an important role in antibody effector functions by modulating the affinity of interaction with Fc receptors displayed on cells of the innate immune system. Rapid, detailed, and quantitative N-glycan analysis is required at all stages of bioprocess development to ensure the safety and efficacy of the therapeutic. The high sample numbers generated during quality by design (QbD) and process analytical technology (PAT) create a demand for high-performance, high-throughput analytical technologies for comprehensive oligosaccharide analysis. We have developed an automated 96-well plate-based sample preparation platform for high-throughput N-glycan analysis using a liquid handling robotic system. Complete process automation includes monoclonal antibody (mAb) purification directly from bioreactor media, glycan release, fluorescent labeling, purification, and subsequent ultra-performance liquid chromatography (UPLC) analysis. The entire sample preparation and commencement of analysis is achieved within a 5-h timeframe. The automated sample preparation platform can easily be interfaced with other downstream analytical technologies, including mass spectrometry (MS) and capillary electrophoresis (CE), for rapid characterization of oligosaccharides present on therapeutic antibodies. Copyright © 2013 Elsevier Inc. All rights reserved.

  9. Clinical Utility of Acetylcholine Receptor Antibody Testing in Ocular Myasthenia Gravis.

    Science.gov (United States)

    Peeler, Crandall E; De Lott, Lindsey B; Nagia, Lina; Lemos, Joao; Eggenberger, Eric R; Cornblath, Wayne T

    2015-10-01

    The sensitivity of acetylcholine receptor (AChR) antibody testing is thought to be lower in ocular myasthenia gravis (OMG) compared with generalized disease, although estimates in small-scale studies vary. There is little information in the literature about the implications of AChR antibody levels and progression from OMG to generalized myasthenia gravis. To test the hypothesis that serum AChR antibody testing is more sensitive in OMG than previously reported and to examine the association between AChR antibody levels and progression from OMG to generalized myasthenia gravis. A retrospective, observational cohort study was conducted of 223 patients (mean [SD] age, 59.2 [16.4] years; 139 [62.3%] male) diagnosed with OMG between July 1, 1986, and May 31, 2013, at 2 large, academic medical centers. Baseline characteristics, OMG symptoms, results of AChR antibody testing, and progression time to generalized myasthenia gravis (if this occurred) were recorded for each patient. Multiple logistic regression was used to measure the association between all clinical variables and antibody result. Kaplan-Meier survival analysis was performed to examine time to generalization. Among the 223 participants, AChR antibody testing results were positive in 158 participants (70.9%). In an adjusted model, increased age at diagnosis (odds ratio [OR], 1.03; 95% CI, 1.01-1.04; P = .007) and progression to generalized myasthenia gravis (OR, 2.92; 95% CI, 1.18-7.26; P = .02) were significantly associated with positive antibody test results. Women were less likely to have a positive antibody test result (OR, 0.36; 95% CI, 0.19-0.68; P = .002). Patients who developed symptoms of generalized myasthenia gravis had a significantly higher mean (SD) antibody level than those who did not develop symptoms of generalized myasthenia gravis (12.7 [16.5] nmol/L vs 4.2 [7.9] nmol/L; P = .002). We demonstrate a higher sensitivity of AChR antibody testing than previously reported in the

  10. Comparison between the Counter Immunoelectrophoresis Test and Mouse Neutralization Test for the Detection of Antibodies against Rabies Virus in Dog Sera

    Directory of Open Access Journals (Sweden)

    Luzia Helena Queiroz da Silva

    2002-03-01

    Full Text Available The detection of rabies antibodies is extremely valuable for epidemiological studies, determination of immune status in man, animals, and for the diagnosis of the disease. Several serological procedures have been described for this purpose. The present study reports a comparison between counterimmunoelectrophoresis test (CIET and mouse neutralization test (MNT in the detection of antibodies against rabies virus from 212 serum samples of vaccinated dogs. The agreement between both techniques was 79.7% and a significative association was demonstrated. The correlation coefficients between MNT and the CIET titers was determined considering 88 samples showing positive results in both techniques [CIET = 2 and MNT = 5 (0.13 IU/ml] and resulted r² = 0.7926 (p < 0.001. The performance of CIET system was technically simple, cheap and rapid, and thereby it could be useful for serological monitoring of dog vaccination campaigns as well as for individual analysis.

  11. Lymphocyte antibody-dependent cytotoxicity test for evaluation of clinical role of monoclonal anti-D-antibodies for prevention of rhesus sensitization.

    Science.gov (United States)

    Olovnikova, N I; Belkina, E V; Nikolaeva, T L; Miterev, G Yu; Chertkov, I L

    2006-01-01

    Monoclonal antibodies to D antigen were studied in the reaction of antibody-dependent cytotoxicity for evaluation of the possibility of using these antibodies for preventing rhesus sensitization. High hemolytic activity of four anti-D-monoclonal antibodies in the antibody-dependent cytotoxicity test, mediated by their interaction with FcgammaRI, and the capacity to accelerate elimination of D+ erythrocytes from circulation did not provide the immunosuppressive effect. It was hypothesized that monoclonal antibodies for prevention of rhesus sensitization should interact with FcgammaRIII on lymphocytes. These monoclonal antibodies are extremely rare: only 4 of 125 studied antibodies mediated hemolysis in the antibody-dependent cytotoxicity test with lymphocytes, while all polyclonal anti-D-preparations exhibited this activity.

  12. A novel lentiviral scFv display library for rapid optimization and selection of high affinity antibodies.

    Science.gov (United States)

    Qudsia, Sehar; Merugu, Siva B; Mangukiya, Hitesh B; Hema, Negi; Wu, Zhenghua; Li, Dawei

    2018-04-30

    Antibody display libraries have become a popular technique to screen monoclonal antibodies for therapeutic purposes. An important aspect of display technology is to generate an optimization library by changing antibody affinity to antigen through mutagenesis and screening the high affinity antibody. In this study, we report a novel lentivirus display based optimization library antibody in which Agtuzumab scFv is displayed on cell membrane of HEK-293T cells. To generate an optimization library, hotspot mutagenesis was performed to achieve diverse antibody library. Based on sequence analysis of randomly selected clones, library size was estimated approximately to be 1.6 × 10 6 . Lentivirus display vector was used to display scFv antibody on cell surface and flow cytometery was performed to check the antibody affinity to antigen. Membrane bound scFv antibodies were then converted to secreted antibody through cre/loxP recombination. One of the mutant clones, M8 showed higher affinity to antigen in flow cytometery analysis. Further characterization of cellular and secreted scFv through western blot showed that antibody affinity was increased by three fold after mutagenesis. This study shows successful construction of a novel antibody library and suggests that hotspot mutagenesis could prove a useful and rapid optimization tool to generate similar libraries with various degree of antigen affinity. Copyright © 2018 Elsevier Inc. All rights reserved.

  13. Prospective evaluation of commercial antibody-based rapid tests in combination with a loop-mediated isothermal amplification PCR assay for detection of Orientia tsutsugamushi during the acute phase of scrub typhus infection.

    Science.gov (United States)

    Blacksell, Stuart D; Paris, Daniel H; Chierakul, Wirongrong; Wuthiekanun, Vanaporn; Teeratakul, Achara; Kantipong, Pacharee; Day, Nicholas P J

    2012-03-01

    Samples from 160 prospectively recruited febrile patients with typhus-like illness in an area of Thailand (Chiang Rai, northern Thailand) where scrub typhus is endemic were used to evaluate the diagnostic capabilities of four rapid immunochromatographic tests (ICTs) for the detection of Orientia tsutsugamushi IgM and total antibodies during acute scrub typhus infection. Of the 160 cases, 54 (34%) had been confirmed to have scrub typhus using the reference scrub typhus infection criteria (STIC), i.e., positive cell culture isolation, an admission IgM antibody titer of ≥1:12,800, a 4-fold rising IgM antibody titer, and/or positivity for ≥2 out of 3 PCR gene targets). The ICTs gave the following sensitivities and specificities: the Panbio IgM ICT, 46% (95% confidence interval [CI], 33 to 60) and 95% (95% CI, 89 to 98), respectively; the Standard Diagnostics IgM ICT, 68% (95% CI, 60 to 75) and 73% (95% CI, 68 to 78), respectively; the AccessBio IgM ICT, 56% (95% CI, 48 to 63) and 90% (95% CI, 87 to 94), respectively; and the AccessBio total antibody ABt ICT, 61% (95% CI, 53 to 68) and 68% (95% CI, 63 to 73), respectively. An isothermal loop amplification (LAMP) PCR assay for scrub typhus demonstrated a sensitivity of 52% (95% CI, 38 to 66) and a specificity of 94% (95% CI, 88 to 98). This study has revealed the diagnostic limitations of antibody-based assays in an acute care setting. However, the combination of ICTs with LAMP usually increased sensitivity with a minimal reduction in specificity. The best combination, the Panbio IgM ICT and LAMP, resulted in a sensitivity of 67% (95% CI, 53 to 79) and a specificity of 91% (95% CI, 83 to 95). The combination of antibody-based assays with DNA- or antigen-based tests shows promise for improved diagnostic sensitivity.

  14. 21 CFR 864.9175 - Automated blood grouping and antibody test system.

    Science.gov (United States)

    2010-04-01

    ...) Identification. An automated blood grouping and antibody test system is a device used to group erythrocytes (red blood cells) and to detect antibodies to blood group antigens. (b) Classification. Class II (performance... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Automated blood grouping and antibody test system...

  15. Comparison of indirect hemagglutination and 51Chromium release tests for detection of herpes simplex virus types 1 and 2 antibodies in patients with recurrent herpes infections

    International Nuclear Information System (INIS)

    Kesavalu, L.; Seth, P.

    1980-01-01

    Indirect hemagglutination and 51 Cr release tests (IHAT and 51-CRT respectively) were compared in patients with recurrent herpes simplex virus (HSV) infections from whom HSV-1 or HSV-2 was isolated. Both tests were equally sensitive and specific in detecting HSV antibodies. However, IHAT was more specific in detecting homologous HSV antibody response in patients with recurrent HSV-2 infections. Past infections with HSV-1 in the patients with dual infections were detected by determining HSV-type specific antibodies by inhibition of IHAT. Cross absorption studies showed that the antibody reactivity measured by the two tests was qualitatively and quantitatively different. Nevertheless, IHAT has been found to be more appropriate test for seroepidemiologic studies of HSV-2 infections because of its specificity, rapidity and less cost, whereas, 51-CRT appears to measure antibodies against recent and more predominant type of infecting HSV. (Author)

  16. Development of microLIPS (Luciferase Immunoprecipitation Systems): a novel microfluidic assay for rapid serum antibody detection

    Science.gov (United States)

    Chandrangsu, Matt; Burbelo, Peter D.; Iadarola, Michael J.; Smith, Paul D.; Morgan, Nicole Y.

    2012-06-01

    There is considerable interest in the development of rapid, point-of-care antibody detection for the diagnosis of infectious and auto-immune diseases. In this paper, we present work on the development of a self-contained microfluidic format for the Luciferase Immunoprecipitation Systems (LIPS) assay. Whereas the majority of immunoassays for antigen-specific antibodies employ either bacteria- or yeast-expressed proteins and require the use of secondary antibodies, the LIPS technique uses a fusion protein comprised of a Renilla luciferase reporter and the antigen of interest produced via mammalian cell culture, ensuring the addition of mammalian post-translational modifications. Patient serum is mixed with the fusion protein and passed over immobilized Protein A/G; after washing, the only remaining luciferase-tagged antigens are those retained by specific antibodies. These can be quantitatively measured using chemiluminescence upon the introduction of coelenterazine. The assay has been successfully employed for a wide variety of diseases in a microwell format. We report on a recent demonstration of rapid HSV-2 diagnosis with the LIPS assay in a microfluidic format, using one microliter of serum and obtaining results in under ten minutes. We will also discuss recent progress on two fronts, both aimed at the deployment of this technology in the field: first, simplifying assay operation through the automation of flow control using power-free means; and second, efforts to increase signal levels, primarily through strategies to increase antibody binding capacity, in order to move towards portable battery powered electronics.

  17. Development of a multiplex lateral flow strip test for foot-and-mouth disease virus detection using monoclonal antibodies.

    Science.gov (United States)

    Yang, Ming; Caterer, Nigel R; Xu, Wanhong; Goolia, Melissa

    2015-09-01

    Foot-and-mouth disease (FMD) is one of the world's most highly contagious animal diseases with tremendous economic consequences. A rapid and specific test for FMD diagnosis at the site of a suspected outbreak is crucial for the implementation of control measures. This project developed a multiplex lateral flow immunochromatographic strip test (multiplex-LFI) for the rapid detection and serotyping of FMD viruses. The monoclonal antibodies (mAbs) against serotypes O, A, and Asia 1 were used as capture mAbs. The mAbs were conjugated with fluorescein, rhodamine or biotin for serotype O, A and Asia 1, respectively. The detection mAbs which consisted of a serotype-independent mAb in combination with one serotype A-specific mAb and one Asia 1-specific mAb, were each colloidal gold-conjugated. The strips used in this study contained one control line and three test lines, which corresponded to one of the three serotypes, O, A or Asia 1. The newly developed multiplex-LFI strip test specifically identified serotype O (n=46), A (n=45) and Asia 1 (n=17) in all tested field isolates. The sensitivity of this strip test was comparable to the double antibody sandwich ELISA for serotypes O and A, but lower than the ELISA for serotype Asia 1. The multiplex-LFI strip test identified all tissue suspensions from animals that were experimentally inoculated with serotypes O, A or Asia 1. FMD viruses were detected in 38% and 50% of the swab samples from the lesion areas of experimentally inoculated sheep for serotypes O and A, respectively. The capability of the multiplex-LFI strip tests to produce rapid results with high specificity for FMD viruses of multiple serotypes makes this test a valuable tool to detect FMD viruses at outbreak sites. Crown Copyright © 2015. Published by Elsevier B.V. All rights reserved.

  18. 21 CFR 866.5785 - Anti-Saccharomyces cerevisiae (S. cerevisiae) antibody (ASCA) test systems.

    Science.gov (United States)

    2010-04-01

    ...) antibody (ASCA) test systems. 866.5785 Section 866.5785 Food and Drugs FOOD AND DRUG ADMINISTRATION... Immunological Test Systems § 866.5785 Anti-Saccharomyces cerevisiae (S. cerevisiae) antibody (ASCA) test systems. (a) Identification. The Anti-Saccharomyces cerevisiae (S. cerevisiae) antibody (ASCA) test system is...

  19. Direct, Specific and Rapid Detection of Staphylococcal Proteins and Exotoxins Using a Multiplex Antibody Microarray.

    Directory of Open Access Journals (Sweden)

    Bettina Stieber

    Full Text Available S. aureus is a pathogen in humans and animals that harbors a wide variety of virulence factors and resistance genes. This bacterium can cause a wide range of mild to life-threatening diseases. In the latter case, fast diagnostic procedures are important. In routine diagnostic laboratories, several genotypic and phenotypic methods are available to identify S. aureus strains and determine their resistances. However, there is a demand for multiplex routine diagnostic tests to directly detect staphylococcal toxins and proteins.In this study, an antibody microarray based assay was established and validated for the rapid detection of staphylococcal markers and exotoxins. The following targets were included: staphylococcal protein A, penicillin binding protein 2a, alpha- and beta-hemolysins, Panton Valentine leukocidin, toxic shock syndrome toxin, enterotoxins A and B as well as staphylokinase. All were detected simultaneously within a single experiment, starting from a clonal culture on standard media. The detection of bound proteins was performed using a new fluorescence reading device for microarrays.110 reference strains and clinical isolates were analyzed using this assay, with a DNA microarray for genotypic characterization performed in parallel. The results showed a general high concordance of genotypic and phenotypic data. However, genotypic analysis found the hla gene present in all S. aureus isolates but its expression under given conditions depended on the clonal complex affiliation of the actual isolate.The multiplex antibody assay described herein allowed a rapid and reliable detection of clinically relevant staphylococcal toxins as well as resistance- and species-specific markers.

  20. Comparative efficacy of antigen and antibody detection tests for human trichinellosis

    International Nuclear Information System (INIS)

    Ivanoska, D.; Cuperlovic, K.; Gamble, H.R.; Murrell, K.D.

    1989-01-01

    Sera collected from patients with suspected or confirmed exposure to Trichinella spiralis were tested for circulating parasite antigens and antiparasite antibodies. Using an immunoradiometric assay, excretory--secretory antigens from muscle-stage larvae of T. spiralis were detected in the sera of 47% of 62 patients with clinical trichinellosis and 13% of 39 patients without clinical signs but suspected of exposure to infected meat. In comparison, antibodies were detected using an indirect immunofluorescent test in the circulation of 100% of the 62 patients with clinical trichinellosis and 46% of the 39 patients with suspected exposure. The presence of antibodies specific to excretory-secretory products of T. spiralis muscle larvae was confirmed in the majority of the samples tested by a monoclonal antibody-based competitive inhibition assay. These results indicate that antibody detection is a more sensitive diagnostic method for human trichinellosis, but that antigen detection might be a useful confirmatory test because it is a direct demonstration of parasite products in the circulation

  1. An ultra-sensitive monoclonal antibody-based fluorescent microsphere immunochromatographic test strip assay for detecting aflatoxin M1 in milk

    Science.gov (United States)

    A rapid lateral flow fluorescent microspheres immunochromatography test strip (FMs-ICTS) has been developed for the detection of aflatoxin M1 (AFM1) residues in milk. For this purpose, an ultra-sensitive anti-AFM1 monoclonal antibody (MAb) 1D3 was prepared and identified. The IC50 value of the MA...

  2. Combined rapid (TUBEX test for typhoid-paratyphoid A fever based on strong anti-O12 response: design and critical assessment of sensitivity.

    Directory of Open Access Journals (Sweden)

    Meiying Yan

    Full Text Available Rapid diagnostics can be accurate but, often, those based on antibody detection for infectious diseases are unwittingly underrated for various reasons. Herein, we described the development of a combined rapid test for two clinically-indistinguishable bacterial diseases, typhoid and paratyphoid A fever, the latter fast emerging as a global threat. By using monoclonal antibodies (mAbs to bacterial antigens of known chemical structures as probes, we were able to dissect the antibody response in patients at the level of monosaccharides. Thus, a mAb specific for a common lipopolysaccharide antigen (O12 found in both the causative organisms was employed to semi-quantify the amounts of anti-O12 antibodies present in both types of patients in an epitope-inhibition particle-based (TUBEX immunoassay. This colorimetric assay detected not only anti-O12 antibodies that were abundantly produced, but also, by steric hindrance, antibodies to an adjoining epitope (O9 or O2 in the typhoid or paratyphoid bacillus, respectively. Sensitivity and, particularly, reaction intensities, were significantly better than those obtained using an anti-O9 or anti-O2 mAb-probe in the examination of paired sera from 22 culture-confirmed typhoid patients (sensitivity, 81.8% vs 75.0% or single sera from 36 culture-confirmed paratyphoid patients (52.8% vs 28.6, respectively. Importantly, sensitivity was better (97.1% for typhoid, 75.0% for paratyphoid if allowance was made for the absence of relevant antibodies in certain specimens as determined by an independent, objective assay (ELISA--such specimens might have been storage-denatured (especially the older paratyphoid samples or procured from non-responders. Benchmarking against ELISA, which revealed high concordance between the two tests, was useful and more appropriate than comparing with culture methods as traditionally done, since antibody tests and culture target slightly different stages of these diseases. Paired sera

  3. Magnetic Fe3O4@TiO2 Nanoparticles-based Test Strip Immunosensing Device for Rapid Detection of Phosphorylated Butyrylcholinesterase

    Energy Technology Data Exchange (ETDEWEB)

    Ge, Xiaoxiao; Zhang, Weiying; Lin, Yuehe; Du, Dan

    2013-12-15

    An integrated magnetic nanoparticles-based test-strip immunosensing device was developed for rapid and sensitive quantification of phosphorylated butyrylcholinesterase (BChE), the biomarker of exposure to organophosphous pesticides (OP), in human plasma. In order to overcome the difficulty in scarce availability of OP-specific antibody, here magnetic Fe3O4@TiO2 nanoparticles were used and adsorbed on the test strip through a small magnet inserted in the device to capture target OP-BChE through selective binding between TiO2 and OP moiety. Further recognition was completed by horseradish peroxidase (HRP) and anti-BChE antibody (Ab) co-immobilized gold nanoparticles (GNPs). Their strong affinities among Fe3O4@TiO2, OP-BChE and HRP/Ab-GNPs were characterized by quartz crystal microbalance (QCM), surface plasmon resonance (SPR) and square wave voltammetry (SWV) measurements. After cutting off from test strip, the resulted immunocomplex (HRP/Ab-GNPs/OP-BChE/Fe3O4@TiO2) was measured by SWV using a screen printed electrode under the test zone. Greatly enhanced sensitivity was achieved by introduction of GNPs to link enzyme and antibody at high ratio, which amplifies electrocatalytic signal significantly. Moreover, the use of test strip for fast immunoreactions reduces analytical time remarkably. Coupling with a portable electrochemical detector, the integrated device with advanced nanotechnology displays great promise for sensitive, rapid and in-filed on-site evaluation of OP poisoning.

  4. Evaluation of a rapid immunochromatographic dipstick test for detection of antibodies to Trypanosoma cruzi in dogs experimentally infected with isolates obtained from opossums (Didelphis virginiana), armadillos (Dasypus novemcinctus), and dogs (Canis familiaris) from the United States.

    Science.gov (United States)

    Rosypal, Alexa C; Hill, Roderick; Lewis, Samantha; Barr, Stephen C; Valadas, Samantha; Gennari, Solange Maria; Lindsay, David S

    2011-02-01

    Dogs are reservoir hosts for Trypanosoma cruzi , the causative agent of American trypanosomiasis. A rapid immunochromatographic dipstick test (ICT) is available commercially for canine serological testing. The ICT was developed with the use of sera from South American dogs, but it is not routinely used in the United States. We evaluated the utility of the ICT in detecting anti-T. cruzi antibodies in dogs from the United States. Dogs (N  =  64) were experimentally infected with United States' isolates of T. cruzi from an opossum (Didelphis virginiana), an armadillo (Dasypus novemcinctus), and a domestic dog (Canis familiaris), and were tested after experimental infection. Sera from uninfected United States dogs (n  =  79; hemaculture negative) were used as negative controls. In a blind study, sera were tested by the ICT and compared to the indirect immunofluorescent antibody test with the use of Brazil-strain epimastigotes as antigen. The sensitivity of the ICT was 91% and the specificity was 98% in dogs experimentally infected with United States isolates. Our study indicates that the ICT could be a useful screening tool for serological surveillance of canine T. cruzi exposure in the United States.

  5. Amperometric biosensor based on a single antibody of dual function for rapid detection of Streptococcus agalactiae.

    Science.gov (United States)

    Vásquez, Gersson; Rey, Alba; Rivera, Camilo; Iregui, Carlos; Orozco, Jahir

    2017-01-15

    Pathogenic bacteria are responsible for several diseases in humans and in a variety of hosts. Detection of pathogenic bacteria is imperative to avoid and/or fight their potential harmful effects. This work reports on the first amperometric biosensor for the rapid detection of Streptococcus agalactiae (S. agalactiae). The biosensor relies on a single biotinylated antibody that immobilizes the bacteria on a screen-printed carbon electrode while is further linked to a streptavidin-conjugated HRP reporter. The biotinylated antibody provides selectivity to the biosensor whereas serves as an anchoring point to the reporter for further amplification of the electrochemical signal. The resultant immunosensor is simple, responds rapidly, and allows for the selective and highly sensitive quantification of S. agalactiae cells in a concentration range of 10 1 -10 7 CFUml -1 , with a detection limit of 10CFUml -1 . The approach not only enables a rapid detection and quantification of S. agalactiae in environmental samples but also opens up new opportunities for the simple fabrication of electrochemical immunosensors for different target pathogens. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Validation of the rapid fluorescent focus inhibition test for rabies virus-neutralizing antibodies in clinical samples

    NARCIS (Netherlands)

    Kostense, Stefan; Moore, Susan; Companjen, Arjen; Bakker, Alexander B. H.; Marissen, Wilfred E.; von Eyben, Rie; Weverling, Gerrit Jan; Hanlon, Cathleen; Goudsmit, Jaap

    2012-01-01

    Monoclonal antibodies are successful biologics in treating a variety of diseases, including the prevention or treatment of viral infections. CL184 is a 1:1 combination of two human monoclonal IgG1 antibodies (CR57 and CR4098) against rabies virus, produced in the PER.C6 human cell line. The two

  7. An ELISA-inhibition test using monoclonal antibody for the serology of leprosy

    NARCIS (Netherlands)

    Klatser, P. R.; de Wit, M. Y.; Kolk, A. H.

    1985-01-01

    In this study a mouse monoclonal antibody (47-9) is described, which recognized an epitope on the 36 kD protein antigen of M. leprae. The monoclonal antibody showed specificity for M. leprae. An ELISA-inhibition test based on the competitive inhibition by antibodies from human test sera of the

  8. Incorporating Direct Rapid Immunohistochemical Testing into Large-Scale Wildlife Rabies Surveillance

    Directory of Open Access Journals (Sweden)

    Kevin Middel

    2017-06-01

    Full Text Available Following an incursion of the mid-Atlantic raccoon variant of the rabies virus into southern Ontario, Canada, in late 2015, the direct rapid immunohistochemical test for rabies (dRIT was employed on a large scale to establish the outbreak perimeter and to diagnose specific cases to inform rabies control management actions. In a 17-month period, 5800 wildlife carcasses were tested using the dRIT, of which 307 were identified as rabid. When compared with the gold standard fluorescent antibody test (FAT, the dRIT was found to have a sensitivity of 100% and a specificity of 98.2%. Positive and negative test agreement was shown to be 98.3% and 99.1%, respectively, with an overall test agreement of 98.8%. The average cost to test a sample was $3.13 CAD for materials, and hands-on technical time to complete the test is estimated at 0.55 h. The dRIT procedure was found to be accurate, fast, inexpensive, easy to learn and perform, and an excellent tool for monitoring the progression of a wildlife rabies incursion.

  9. Male Partner Risk Behaviors Are Associated With Reactive Rapid HIV Antibody Tests Among Pregnant Mexican Women: Implications for Prevention of Vertical and Sexual HIV Transmission in Concentrated HIV Epidemics.

    Science.gov (United States)

    Rivero, Estela; Kendall, Tamil

    2015-01-01

    Mexico's policies on antenatal HIV testing are contradictory, and little is known about social and behavioral characteristics that increase pregnant Mexican women's risks of acquiring HIV. We analyzed the association between risk behaviors reported by pregnant women for themselves and their male partners, and women's rapid HIV antibody test results from a large national sample. Three quarters of pregnant women with a reactive test did not report risk behaviors for themselves and one third did not report risk behaviors for themselves or their male partners. In the retrospective case-control analysis, other than reporting multiple sexual partners, reactive pregnant women reported risk behaviors did not differ from nonreactive women's behaviors. However, reactive pregnant women were significantly more likely to have reported risk behaviors for male partners. Our findings support universal offer of antenatal HIV testing and suggest that HIV prevention for women should focus on reducing risk of HIV acquisition within stable relationships. Copyright © 2015 Association of Nurses in AIDS Care. Published by Elsevier Inc. All rights reserved.

  10. EPSTEIN-BARR VIRUS INFECTIONS – AVIDITY TEST FOR IgG ANTIBODIES

    Directory of Open Access Journals (Sweden)

    Katja Strašek

    2001-06-01

    Full Text Available Background. We wish to introduce specific IgG avidity test as a supplementary assay in serological screening for Epstein-Barr virus infection if the status of patient cannot be resolved from a single serum sample with routine testing.Methods. Avidity of IgG antibodies was determined in sera of 57 patients with different stage of Epstein-Barr virus infection. Enzyme-immuno assay was used with a short incubation of 6-molar urea included in the procedure. Urea should remove low avidity antibodies. Avidity was expressed as the avidity index. Avidity testing with commercial kit was done as well.Results. Low avidity index was found for IgG antibodies of acute phase sera and high for those of past infection, recent infection and reactivation of endogenic virus.Conclusions. Avidity test for IgG antibodies might be supplementary assay to prove acute infection but also to resolve some other clinical states related to Epstein-Barr virus.

  11. Evaluation of simple rapid HIV assays and development of national rapid HIV test algorithms in Dar es Salaam, Tanzania.

    Science.gov (United States)

    Lyamuya, Eligius F; Aboud, Said; Urassa, Willy K; Sufi, Jaffer; Mbwana, Judica; Ndugulile, Faustin; Massambu, Charles

    2009-02-18

    Suitable algorithms based on a combination of two or more simple rapid HIV assays have been shown to have a diagnostic accuracy comparable to double enzyme-linked immunosorbent assay (ELISA) or double ELISA with Western Blot strategies. The aims of this study were to evaluate the performance of five simple rapid HIV assays using whole blood samples from HIV-infected patients, pregnant women, voluntary counseling and testing attendees and blood donors, and to formulate an alternative confirmatory strategy based on rapid HIV testing algorithms suitable for use in Tanzania. Five rapid HIV assays: Determine HIV-1/2 (Inverness Medical), SD Bioline HIV 1/2 3.0 (Standard Diagnostics Inc.), First Response HIV Card 1-2.0 (PMC Medical India Pvt Ltd), HIV1/2 Stat-Pak Dipstick (Chembio Diagnostic System, Inc) and Uni-Gold HIV-1/2 (Trinity Biotech) were evaluated between June and September 2006 using 1433 whole blood samples from hospital patients, pregnant women, voluntary counseling and testing attendees and blood donors. All samples that were reactive on all or any of the five rapid assays and 10% of non-reactive samples were tested on a confirmatory Inno-Lia HIV I/II immunoblot assay (Immunogenetics). Three hundred and ninety samples were confirmed HIV-1 antibody positive, while 1043 were HIV negative. The sensitivity at initial testing of Determine, SD Bioline and Uni-Gold was 100% (95% CI; 99.1-100) while First Response and Stat-Pak had sensitivity of 99.5% (95% CI; 98.2-99.9) and 97.7% (95% CI; 95.7-98.9), respectively, which increased to 100% (95% CI; 99.1-100) on repeat testing. The initial specificity of the Uni-Gold assay was 100% (95% CI; 99.6-100) while specificities were 99.6% (95% CI; 99-99.9), 99.4% (95% CI; 98.8-99.7), 99.6% (95% CI; 99-99.9) and 99.8% (95% CI; 99.3-99.9) for Determine, SD Bioline, First Response and Stat-Pak assays, respectively. There was no any sample which was concordantly false positive in Uni-Gold, Determine and SD Bioline assays. An

  12. A rapid radioimmunoassay using 125I-labeled staphylococcal protein A for antibody to varicella-zoster virus

    International Nuclear Information System (INIS)

    Richman, D.D.; Cleveland, P.H.; Oxman, M.N.; Zaia, J.A.

    1981-01-01

    A sensitive radioimmunoassay for serum antibody to varicella-zoster virus is described; it uses 125I-labeled staphylococcal protein A and a specially designed immunofiltration apparatus. The assay accurately distinguishes between individuals who are susceptible and those who are immune to infection with varicella-zoster virus. In addition, it can detect passive antibody in recipients of varicella-zoster immune globulin. This radioimmunoassay also detects the heterologous antibody responses that occasionally occur in patients infected with herpes simplex virus, which also have been detected by other antibody assays. The particular advantages of this assay are the use of noninfectious reagents, the speed of execution (less than 3 hr), the requirement for only small quantities of serum (30 microliters), the objectivity of end-point determination, and the capability of screening large numbers of sera. Consequently, this radioimmunoassay is especially useful for the rapid identification of susceptible individuals, which is essential for the appropriate management of patients and hospital personnel after exposure to varicella

  13. Detection of antibodies to transmissible gastroenteritis virus of swine by modified autoradiographic test

    Energy Technology Data Exchange (ETDEWEB)

    Stepanek, J; Hampl, J; Franz, J; Mensik, P; Skrobak, F [Vyzkumny Ustav Veterinarniho Lekarstvi, Brno-Medlanky (Czechoslovakia)

    1982-08-01

    A modified method of autoradiographic determination of virus antibodies of gastroenteritis of swine was developed. It is based on the actual reaction between antigen bound in cells of the infected cell cultures and antibodies in tested sera, which is visualized by rabbit antibodies labelled with /sup 125/I (/sup 125/I RaSw IgG antibody) to porcine IgG, on a sensitive radiograph and evaluated by darkening at the point of positive immunological reaction. Specificity of the test and mutual comparability and reproducibility of the results were confirmed by examining the known positive and negative sera and by a comparison with the results of the virus-neutralization test. Of the 36 examined porcine blood sera, antibodies were only proved autoradiographically in the samples positive also by virus-neutralization. In experimentally infected pigs, the same dynamics of antibody production was recorded by the two tests. They were, however, demonstrated autoradiographically the eighth day after infection, while by virus neutralization test as late as 14th day. Their level increased gradually till 35th day after infection.

  14. Evaluation of ID-PaGIA syphilis antibody test.

    Science.gov (United States)

    Naaber, Paul; Makoid, Ene; Aus, Anneli; Loivukene, Krista; Poder, Airi

    2009-01-01

    Laboratory diagnosis of syphilis is usually accomplished by serology. There are currently a large number of different commercial treponemal tests available that vary in format, sensitivity and specificity. To evaluate the ID-PaGIA Syphilis Antibody Test as an alternative to other specific treponemal tests for primary screening or confirmation of diagnosis. Serum samples from healthy adults (n = 100) were used for detection of specificity of ID-PaGIA. To evaluate sensitivity of ID-PaGIA serum samples (n = 101) from patients with confirmed or suspected syphilis were tested for syphilis antibodies with FTA-Abs IgM, ID-PaGIA, ELISA IgM and TPHA tests. No false-positive results were found with ID-PaGIA. Sensitivity of various treponemal tests was the following: FTA-Abs IgM: 95.5%, ID-PaGIA and ELISA IgM: 94%, and TPHA 75%. The positive and negative predictive values of ID-PaGIA were 100 and 89.5%, respectively. Compared with other treponemal tests ID-PaGIA has excellent sensitivity and specificity.

  15. Bulk tank milk ELISA for detection of antibodies to Mycobacterium avium subsp paratuberculosis: Correlation between repeated tests and within-herd antibody-prevalence

    DEFF Research Database (Denmark)

    Nielsen, Søren Saxmose; Toft, Nils

    2014-01-01

    Detection of bulk tank milk (BTM) antibodies using ELISA (BTM-ELISA) may constitute an inexpensive test for surveillance of Mycobacterium avium subsp. paratuberculosis (MAP) infection in dairy cattle herds provided that the test is accurate and consistent. The objectives of this study were...... Danish Holstein herds over a period of one year. All samples were tested using a commercial indirect ELISA for detection of MAP specific antibodies. The individual cow's results were dichotomised and used to estimate the within-herd antibody prevalence at each test-date. These prevalences were...... to 0.60 when corrected for the within-herd antibody prevalence. Although the test-results were relatively consistent and correlated with the within-herd prevalence, the magnitude of the test-values makes it difficult to use the BTM-ELISA for surveillance of MAP infections in practice....

  16. A Novel Tool for High-Throughput Screening of Granulocyte-Specific Antibodies Using the Automated Flow Cytometric Granulocyte Immunofluorescence Test (Flow-GIFT

    Directory of Open Access Journals (Sweden)

    Xuan Duc Nguyen

    2011-01-01

    Full Text Available Transfusion-related acute lung injury (TRALI is a severe complication related with blood transfusion. TRALI has usually been associated with antibodies against leukocytes. The flow cytometric granulocyte immunofluorescence test (Flow-GIFT has been introduced for routine use when investigating patients and healthy blood donors. Here we describe a novel tool in the automation of the Flow-GIFT that enables a rapid screening of blood donations. We analyzed 440 sera from healthy female blood donors for the presence of granulocyte antibodies. As positive controls, 12 sera with known antibodies against anti-HNA-1a, -b, -2a; and -3a were additionally investigated. Whole-blood samples from HNA-typed donors were collected and the test cells isolated using cell sedimentation in a Ficoll density gradient. Subsequently, leukocytes were incubated with the respective serum and binding of antibodies was detected using FITC-conjugated antihuman antibody. 7-AAD was used to exclude dead cells. Pipetting steps were automated using the Biomek NXp Multichannel Automation Workstation. All samples were prepared in the 96-deep well plates and analyzed by flow cytometry. The standard granulocyte immunofluorescence test (GIFT and granulocyte agglutination test (GAT were also performed as reference methods. Sixteen sera were positive in the automated Flow-GIFT, while five of these sera were negative in the standard GIFT (anti—HNA 3a, n = 3; anti—HNA-1b, n = 1 and GAT (anti—HNA-2a, n = 1. The automated Flow-GIFT was able to detect all granulocyte antibodies, which could be only detected in GIFT in combination with GAT. In serial dilution tests, the automated Flow-GIFT detected the antibodies at higher dilutions than the reference methods GIFT and GAT. The Flow-GIFT proved to be feasible for automation. This novel high-throughput system allows an effective antigranulocyte antibody detection in a large donor population in order to prevent TRALI due to transfusion of

  17. A novel tool for high-throughput screening of granulocyte-specific antibodies using the automated flow cytometric granulocyte immunofluorescence test (Flow-GIFT).

    Science.gov (United States)

    Nguyen, Xuan Duc; Dengler, Thomas; Schulz-Linkholt, Monika; Klüter, Harald

    2011-02-03

    Transfusion-related acute lung injury (TRALI) is a severe complication related with blood transfusion. TRALI has usually been associated with antibodies against leukocytes. The flow cytometric granulocyte immunofluorescence test (Flow-GIFT) has been introduced for routine use when investigating patients and healthy blood donors. Here we describe a novel tool in the automation of the Flow-GIFT that enables a rapid screening of blood donations. We analyzed 440 sera from healthy female blood donors for the presence of granulocyte antibodies. As positive controls, 12 sera with known antibodies against anti-HNA-1a, -b, -2a; and -3a were additionally investigated. Whole-blood samples from HNA-typed donors were collected and the test cells isolated using cell sedimentation in a Ficoll density gradient. Subsequently, leukocytes were incubated with the respective serum and binding of antibodies was detected using FITC-conjugated antihuman antibody. 7-AAD was used to exclude dead cells. Pipetting steps were automated using the Biomek NXp Multichannel Automation Workstation. All samples were prepared in the 96-deep well plates and analyzed by flow cytometry. The standard granulocyte immunofluorescence test (GIFT) and granulocyte agglutination test (GAT) were also performed as reference methods. Sixteen sera were positive in the automated Flow-GIFT, while five of these sera were negative in the standard GIFT (anti-HNA 3a, n = 3; anti-HNA-1b, n = 1) and GAT (anti-HNA-2a, n = 1). The automated Flow-GIFT was able to detect all granulocyte antibodies, which could be only detected in GIFT in combination with GAT. In serial dilution tests, the automated Flow-GIFT detected the antibodies at higher dilutions than the reference methods GIFT and GAT. The Flow-GIFT proved to be feasible for automation. This novel high-throughput system allows an effective antigranulocyte antibody detection in a large donor population in order to prevent TRALI due to transfusion of blood products.

  18. Comparison of the Cerebrospinal Fluid (CSF) Toluidine Red Unheated Serum Test and the CSF Rapid Plasma Reagin Test with the CSF Venereal Disease Research Laboratory Test for Diagnosis of Neurosyphilis among HIV-Negative Syphilis Patients in China

    OpenAIRE

    Zhu, Lin; Gu, Xin; Peng, Rui-Rui; Wang, Cuini; Gao, Zixiao; Zhou, Pingyu; Gao, Ying; Shi, Mei; Guan, Zhifang; Seña, Arlene C.

    2014-01-01

    In this study, we aimed to investigate the performance of nontreponemal antibody tests in cerebrospinal fluid (CSF) specimens from syphilis patients. From September 2009 to September 2012, CSF specimens were collected at the Shanghai Skin Disease Hospital in Shanghai, China, from 1,132 syphilis patients without HIV infection, including 154 with symptomatic and 56 with asymptomatic neurosyphilis. All of the CSF specimens underwent testing with a rapid plasma reagin (RPR) test, an RPR-V (commer...

  19. An influenza A virus agglutination test using antibody-like polymers.

    Science.gov (United States)

    Sukjee, Wannisa; Thitithanyanont, Arunee; Wiboon-Ut, Suwimon; Lieberzeit, Peter A; Paul Gleeson, M; Navakul, Krongkaew; Sangma, Chak

    2017-10-01

    Antibodies are commonly used in diagnostic routines to identify pathogens. The testing protocols are relatively simple, requiring a certain amount of a specific antibody to detect its corresponding pathogen. Antibody functionality can be mimicked by synthesizing molecularly imprinted polymers (MIPs), i.e. polymers that can selectively recognize a given template structure. Thus, MIPs are sometimes termed 'plastic antibody (PA)'. In this study, we have synthesized new granular MIPs using influenza A virus templates by precipitation polymerization. The selective binding of influenza A to the MIP particles was assessed and subsequently contrasted with other viruses. The affinities of influenza A virus towards the MIP was estimated based on an agglutination test by measuring the amount of influenza subtypes absorbed onto the MIPs. The MIPs produced using the H1N1 template showed specific reactivity to H1N1 while those produced using H5N1 and H3N2 templates showed cross-reactivity.

  20. Evaluation of the rapid plasma reagin "teardrop" card test for screening of syphilis in field conditions.

    Science.gov (United States)

    Van Dyck, E; Van de Velden, L; Ndoye, I; Piot, P; Meheus, A

    1993-01-01

    The availability of simple diagnostic methods may contribute to more efficient control of sexually transmitted diseases (STDs) in developing countries. For the detection of syphilis, a simple rapid plasma reagin (RPR) "teardrop" assay for finger-prick blood samples was developed in 1962. The reliability of this test is compared with RPR, Treponema pallidum hemagglutination assay (TPHA), and fluorescent treponemal antibody absorption (FTA-Abs) assays performed on venous blood samples. To evaluate the potential usefulness of the finger-stick RPR teardrop assay for diagnosis of syphilis in settings with poor medical resources. Pregnant women evaluated at two health centers in Pikine, Senegal were tested for STDs. The RPR teardrop assay was performed on plasma from blood samples obtained by finger prick, and standard RPR, TPHA, and FTA-Abs procedures were performed on serum obtained by vein puncture. The sensitivity and specificity of the finger-prick RPR teardrop assay were 69.7% and 96.5%, respectively, and its reactivity was correlated with RPR serum antibody titer. The finger-prick RPR teardrop assay is not a reliable alternative to the classic serum RPR test.

  1. Dilution testing using rapid diagnostic tests in a HIV diagnostic algorithm: a novel alternative for confirmation testing in resource limited settings.

    Science.gov (United States)

    Shanks, Leslie; Siddiqui, M Ruby; Abebe, Almaz; Piriou, Erwan; Pearce, Neil; Ariti, Cono; Masiga, Johnson; Muluneh, Libsework; Wazome, Joseph; Ritmeijer, Koert; Klarkowski, Derryck

    2015-05-14

    Current WHO testing guidelines for resource limited settings diagnose HIV on the basis of screening tests without a confirmation test due to cost constraints. This leads to a potential risk of false positive HIV diagnosis. In this paper, we evaluate the dilution test, a novel method for confirmation testing, which is simple, rapid, and low cost. The principle of the dilution test is to alter the sensitivity of a rapid diagnostic test (RDT) by dilution of the sample, in order to screen out the cross reacting antibodies responsible for falsely positive RDT results. Participants were recruited from two testing centres in Ethiopia where a tiebreaker algorithm using 3 different RDTs in series is used to diagnose HIV. All samples positive on the initial screening RDT and every 10th negative sample underwent testing with the gold standard and dilution test. Dilution testing was performed using Determine™ rapid diagnostic test at 6 different dilutions. Results were compared to the gold standard of Western Blot; where Western Blot was indeterminate, PCR testing determined the final result. 2895 samples were recruited to the study. 247 were positive for a prevalence of 8.5 % (247/2895). A total of 495 samples underwent dilution testing. The RDT diagnostic algorithm misclassified 18 samples as positive. Dilution at the level of 1/160 was able to correctly identify all these 18 false positives, but at a cost of a single false negative result (sensitivity 99.6 %, 95 % CI 97.8-100; specificity 100 %, 95 % CI: 98.5-100). Concordance between the gold standard and the 1/160 dilution strength was 99.8 %. This study provides proof of concept for a new, low cost method of confirming HIV diagnosis in resource-limited settings. It has potential for use as a supplementary test in a confirmatory algorithm, whereby double positive RDT results undergo dilution testing, with positive results confirming HIV infection. Negative results require nucleic acid testing to rule out false

  2. Clearance of 131I-labeled murine monoclonal antibody from patients' blood by intravenous human anti-murine immunoglobulin antibody

    International Nuclear Information System (INIS)

    Stewart, J.S.; Sivolapenko, G.B.; Hird, V.; Davies, K.A.; Walport, M.; Ritter, M.A.; Epenetos, A.A.

    1990-01-01

    Five patients treated with intraperitoneal 131I-labeled mouse monoclonal antibody for ovarian cancer also received i.v. exogenous polyclonal human anti-murine immunoglobulin antibody. The pharmacokinetics of 131I-labeled monoclonal antibody in these patients were compared with those of 28 other patients receiving i.p.-radiolabeled monoclonal antibody for the first time without exogenous human anti-murine immunoglobulin, and who had no preexisting endogenous human anti-murine immunoglobulin antibody. Patients receiving i.v. human anti-murine immunoglobulin antibody demonstrated a rapid clearance of 131I-labeled monoclonal antibody from their circulation. The (mean) maximum 131I blood content was 11.4% of the injected activity in patients receiving human anti-murine immunoglobulin antibody compared to 23.3% in patients not given human anti-murine immunoglobulin antibody. Intravenous human anti-murine immunoglobulin antibody decreased the radiation dose to bone marrow (from 131I-labeled monoclonal antibody in the vascular compartment) 4-fold. Following the injection of human anti-murine immunoglobulin antibody, 131I-monoclonal/human anti-murine immunoglobulin antibody immune complexes were rapidly transported to the liver. Antibody dehalogenation in the liver was rapid, with 87% of the injected 131I excreted in 5 days. Despite the efficient hepatic uptake of immune complexes, dehalogenation of monoclonal antibody was so rapid that the radiation dose to liver parenchyma from circulating 131I was decreased 4-fold rather than increased. All patients developed endogenous human anti-murine immunoglobulin antibody 2 to 3 weeks after treatment

  3. The diagnostic accuracy of three rapid diagnostic tests for typhoid fever at Chittagong Medical College Hospital, Chittagong, Bangladesh.

    Science.gov (United States)

    Maude, Rapeephan R; de Jong, Hanna K; Wijedoru, Lalith; Fukushima, Masako; Ghose, Aniruddha; Samad, Rasheda; Hossain, Mohammed Amir; Karim, Mohammed Rezaul; Faiz, Mohammed Abul; Parry, Christopher M

    2015-10-01

    To determine the diagnostic accuracy of three rapid diagnostic tests (RDTs) for typhoid fever in febrile hospitalised patients in Bangladesh. Febrile adults and children admitted to Chittagong Medical College Hospital, Bangladesh, were investigated with Bact/Alert(®) blood cultures and real-time PCR to detect Salmonella enterica Typhi and Paratyphi A and assays for Rickettsia, leptospirosis and dengue fever. Acute serum samples were examined with the LifeAssay (LA) Test-it™ Typhoid IgM lateral flow assay detecting IgM antibodies against S. Typhi O antigen, CTKBiotech Onsite Typhoid IgG/IgM Combo Rapid-test cassette lateral flow assay detecting IgG and IgM antibodies against S. Typhi O and H antigens and SD Bioline line assay for IgG and IgM antibodies against S. Typhi proteins. In 300 malaria smear-negative febrile patients [median (IQR) age of 13.5 (5-31) years], 34 (11.3%) had confirmed typhoid fever: 19 positive by blood culture for S. Typhi (three blood PCR positive) and 15 blood culture negative but PCR positive for S. Typhi in blood. The respective sensitivity and specificity of the three RDTs in patients using a composite reference standard of blood culture and/or PCR-confirmed typhoid fever were 59% and 61% for LifeAssay, 59% and 74% for the CTK IgM and/or IgG, and 24% and 96% for the SD Bioline RDT IgM and/or IgG. The LifeAssay RDT had a sensitivity of 63% and a specificity of 91% when modified with a positive cut-off of ≥2+ and analysed using a Bayesian latent class model. These typhoid RDTs demonstrated moderate diagnostic accuracies, and better tests are needed. © 2015 The Authors. Tropical Medicine & International Health Published by John Wiley & Sons Ltd.

  4. Antinuclear antibody testing in obstetric patients | Afman | South ...

    African Journals Online (AJOL)

    Objectives. To assess possible associations between the presence of antinuclear antibodies (ANAs) and pregnancy outcome in order to determine the significance of this test in obstetric practice. Methods. A case-control study was performed on 408 patients admitted to an obstetric high care unit and on whom ANA testing ...

  5. An ELISA test for the detection of antibodies to Legionella pneumophila.

    OpenAIRE

    Wreghitt, T G; Nagington, J; Gray, J

    1982-01-01

    An enzyme-linked immunosorbent assay (ELISA) test has been developed to detect antibodies to Legionella pneumophila serogroup 1. There is good correlation between indirect fluorescent antibody (IFA) and ELISA titres but ELISA is more sensitive.

  6. Evaluation of simple rapid HIV assays and development of national rapid HIV test algorithms in Dar es Salaam, Tanzania

    Directory of Open Access Journals (Sweden)

    Mbwana Judica

    2009-02-01

    Full Text Available Abstract Background Suitable algorithms based on a combination of two or more simple rapid HIV assays have been shown to have a diagnostic accuracy comparable to double enzyme-linked immunosorbent assay (ELISA or double ELISA with Western Blot strategies. The aims of this study were to evaluate the performance of five simple rapid HIV assays using whole blood samples from HIV-infected patients, pregnant women, voluntary counseling and testing attendees and blood donors, and to formulate an alternative confirmatory strategy based on rapid HIV testing algorithms suitable for use in Tanzania. Methods Five rapid HIV assays: Determine™ HIV-1/2 (Inverness Medical, SD Bioline HIV 1/2 3.0 (Standard Diagnostics Inc., First Response HIV Card 1–2.0 (PMC Medical India Pvt Ltd, HIV1/2 Stat-Pak Dipstick (Chembio Diagnostic System, Inc and Uni-Gold™ HIV-1/2 (Trinity Biotech were evaluated between June and September 2006 using 1433 whole blood samples from hospital patients, pregnant women, voluntary counseling and testing attendees and blood donors. All samples that were reactive on all or any of the five rapid assays and 10% of non-reactive samples were tested on a confirmatory Inno-Lia HIV I/II immunoblot assay (Immunogenetics. Results Three hundred and ninety samples were confirmed HIV-1 antibody positive, while 1043 were HIV negative. The sensitivity at initial testing of Determine, SD Bioline and Uni-Gold™ was 100% (95% CI; 99.1–100 while First Response and Stat-Pak had sensitivity of 99.5% (95% CI; 98.2–99.9 and 97.7% (95% CI; 95.7–98.9, respectively, which increased to 100% (95% CI; 99.1–100 on repeat testing. The initial specificity of the Uni-Gold™ assay was 100% (95% CI; 99.6–100 while specificities were 99.6% (95% CI; 99–99.9, 99.4% (95% CI; 98.8–99.7, 99.6% (95% CI; 99–99.9 and 99.8% (95% CI; 99.3–99.9 for Determine, SD Bioline, First Response and Stat-Pak assays, respectively. There was no any sample which was

  7. Development of a Rapid Immunodiagnostic Test for Pork Components in Raw Beef and Chicken Meats: a Preliminary Study

    Directory of Open Access Journals (Sweden)

    S. N. Depamede

    2011-08-01

    Full Text Available A rapid immunodiagnostic test that provides visual evidence of the presence of pork components in raw beef and chicken meats was developed. Colloidal gold was prepared and conjugated with anti-Swine IgG polyclonal antibody. Immunochromatographic test strips were produced, and then were used to test laboratory adulterated raw meat samples. The samples consisted adulteration meat, immunodiagnostic, pork, rapid test of pork-in-beef, or pork-in-chicken at 1/0; 1/100; 1/1,000; 1/5,000; 1/10,000 (w/w adulteration levels that were extracted in phosphate-buffered saline. Raw beef and chicken meats without pork were included as controls. Analysis was completed in 10 min. Detection limit was 1/5,000 (w/w, although 1/10,000 was also observed. This immunodiagnostic tests can be conveniently applied to detect low levels of pork components in raw beef and chicken meat products. For the commercial purposes, further studies need to be carried out.

  8. A High-Throughput Antibody-Based Microarray Typing Platform

    Directory of Open Access Journals (Sweden)

    Ashan Perera

    2013-05-01

    Full Text Available Many rapid methods have been developed for screening foods for the presence of pathogenic microorganisms. Rapid methods that have the additional ability to identify microorganisms via multiplexed immunological recognition have the potential for classification or typing of microbial contaminants thus facilitating epidemiological investigations that aim to identify outbreaks and trace back the contamination to its source. This manuscript introduces a novel, high throughput typing platform that employs microarrayed multiwell plate substrates and laser-induced fluorescence of the nucleic acid intercalating dye/stain SYBR Gold for detection of antibody-captured bacteria. The aim of this study was to use this platform for comparison of different sets of antibodies raised against the same pathogens as well as demonstrate its potential effectiveness for serotyping. To that end, two sets of antibodies raised against each of the “Big Six” non-O157 Shiga toxin-producing E. coli (STEC as well as E. coli O157:H7 were array-printed into microtiter plates, and serial dilutions of the bacteria were added and subsequently detected. Though antibody specificity was not sufficient for the development of an STEC serotyping method, the STEC antibody sets performed reasonably well exhibiting that specificity increased at lower capture antibody concentrations or, conversely, at lower bacterial target concentrations. The favorable results indicated that with sufficiently selective and ideally concentrated sets of biorecognition elements (e.g., antibodies or aptamers, this high-throughput platform can be used to rapidly type microbial isolates derived from food samples within ca. 80 min of total assay time. It can also potentially be used to detect the pathogens from food enrichments and at least serve as a platform for testing antibodies.

  9. A Rapid Blood Test To Determine the Active Status and Duration of Acute Viral Infection.

    Science.gov (United States)

    Zheng, Tianyu; Finn, Caroline; Parrett, Christopher J; Dhume, Kunal; Hwang, Ji Hae; Sidhom, David; Strutt, Tara M; Li Sip, Yuen Yee; McKinstry, Karl K; Huo, Qun

    2017-11-10

    The ability to rapidly detect and diagnose acute viral infections is crucial for infectious disease control and management. Serology testing for the presence of virus-elicited antibodies in blood is one of the methods used commonly for clinical diagnosis of viral infections. However, standard serology-based tests have a significant limitation: they cannot easily distinguish active from past, historical infections. As a result, it is difficult to determine whether a patient is currently infected with a virus or not, and on an optimal course of action, based off of positive serology testing responses. Here, we report a nanoparticle-enabled blood test that can help overcome this major challenge. The new test is based on the analysis of virus-elicited immunoglobulin G (IgG) antibody present in the protein corona of a gold nanoparticle surface upon mixing the gold nanoparticles with blood sera. Studies conducted on mouse models of influenza A virus infection show that the test gives positive responses only in the presence of a recent acute viral infection, approximately between day 14 and day 21 following the infection, and becomes negative thereafter. When used together with the traditional serology testing, the nanoparticle test can determine clearly whether a positive serology response is due to a recent or historical viral infection. This new blood test can provide critical clinical information needed to optimize further treatment and/or to determine if further quarantining should be continued.

  10. Avian Diagnostic and Therapeutic Antibodies

    Energy Technology Data Exchange (ETDEWEB)

    Bradley, David Sherman [UND SMHS

    2012-12-31

    A number of infectious agents have the potential of causing significant clinical symptomology and even death, but dispite this, the number of incidence remain below the level that supports producing a vaccine. Therapeutic antibodies provide a viable treatment option for many of these diseases. We proposed that antibodies derived from West Nile Virus (WNV) immunized geese would be able to treat WNV infection in mammals and potential humans. We demonstrated that WNV specific goose antibodies are indeed successful in treating WNV infection both prophylactically and therapeutically in a golden hamster model. We demonstrated that the goose derived antibodies are non-reactogenic, i.e. do not cause an inflammatory response with multiple exposures in mammals. We also developed both a specific pathogen free facility to house the geese during the antibody production phase and a patent-pending purification process to purify the antibodies to greater than 99% purity. Therefore, the success of these study will allow a cost effective rapidly producible therapeutic toward clinical testing with the necessary infrastructure and processes developed and in place.

  11. Thyroglobulin recovery test of sera containing elevated levels of anti-thyroglobulin antibodies

    International Nuclear Information System (INIS)

    Hervas, I.; Gonzalez-Cabezas, P.; Flores, D.; Perez-Pastor, J.L.; Bello, P.; Rivas, A.; Alonso, J.; Olivas, C.; Mateo, A.

    2002-01-01

    Aim: Thyroglobulin (Tg) is a macro-molecule synthesized exclusively in the thyroid gland for the synthesis of thyroid hormones. In differentiated thyroid carcinoma, after radical thyroidectomy, the discovering of measurable quantities of Tg can be indicator of relapse y/or spread of disease but Thyroglobulin antibodies can alter the determination of Tg. The aim of this study is to assess and measure the interference of Tg antibodies on the Tg determination. Methods: We have selected 50 consecutive serum whose Tg-antibodies levels were higher than the normality values (0-100 UI/mL). Tg-antibodies were measured using a 'sandwich' radioimmunometric assay on solid phase. We have performed a recovery test on these sera. This test consists on adding a known quantity (50 UI) of Tg on that sera and then measure the Tg values to find out the percentage of Tg that is recuperated. Tg was measured using a radioimmunometric assay on solid phase. Results: Sera were divided in two groups: A.- 15 sera with Tg-antibodies levels between 100-250 UI/mL: 85% of them presented a Tg recovery percentage higher than 90% (Tg-antibodies did not interfere on Tg values due to Tg was recovered almost in its totality). B.- 53 sera with Tg-antibodies levels higher than 250 UI/mL: Only 10% of them presented a Tg recovery percentage higher than >90% . (90% of sera interfered on Tg values). 70% of that sera presented percentages under 50%. The Pearson's correlation coefficient between Tg-antibodies and Tg recovery percentage was -0.34. Conclusions: The majority (90%)of sera with Tg-antibodies higher than 250 UI/mL presented an high interference on Tg determination. However the majority of sera with Tg-antibodies between 100-250 did not show any interference on Tg determination. There are not linear correlation between highest values and lowest percentages of Tg recovered. We recommend the realization of Tg recovery test on sera with elevated Tg antibodies specially when are higher than 250 UI/mL

  12. Post-marketing surveillance of OraQuick whole blood and oral fluid rapid HIV testing.

    Science.gov (United States)

    Wesolowski, Laura G; MacKellar, Duncan A; Facente, Shelley N; Dowling, Teri; Ethridge, Steven F; Zhu, Julia H; Sullivan, Patrick S

    2006-08-01

    Post-marketing surveillance was conducted to monitor the performance of the OraQuick Advance rapid HIV-1/2 antibody test (OraQuick) on whole blood and oral fluid. Surveillance of routinely collected data on clients tested with OraQuick in 368 testing sites affiliated with 17 state and city health departments between 11 August 2004 and 30 June 2005. For whole blood and oral fluid, we report the median (range) health department OraQuick specificity and positive predictive value (PPV), and the number of clients with discordant results (e.g. who had a reactive rapid test not confirmed positive by Western blot or indirect immunofluorescence). At one site with lower than expected oral-fluid specificity, we evaluated whether device expiration, manufacturing lot, operator practices, or device-storage or testing-area temperatures were associated with false-positive tests. During the surveillance period, 135 724 whole blood and 26 066 oral fluid rapid tests were conducted. The median health department whole blood OraQuick specificity was 99.98% (range: 99.73-100%) and PPV was 99.24% (range: 66.67-100%); the median oral fluid specificity was 99.89% (range: 99.44-100%) and PPV was 90.00% (range: 50.00-100%). A total of 124 discordant results were reported from 68 (0.05%) whole blood and 56 (0.22%) oral fluid rapid tests. The oral fluid specificity at the site with excess oral fluid false-positive tests was 98.7% (95% confidence interval: 98.18-99.11%). The increase in false-positive tests at that site was not associated with any specific device characteristic, operator procedure or temperature condition. The specificity of OraQuick performed on whole blood and oral fluid during post-marketing surveillance was compatible with the manufacturer's claim within the package insert. However, one site experienced lower than expected oral fluid specificity. Sites that observe that the specificity of OraQuick is lower than the range indicated in the package insert should notify the

  13. Clinical Comparison of the Treponema pallidum CAPTIA Syphilis-G Enzyme Immunoassay with the Fluorescent Treponemal Antibody Absorption Immunoglobulin G Assay for Syphilis Testing

    OpenAIRE

    Halling, V. W.; Jones, M. F.; Bestrom, J. E.; Wold, A. D.; Rosenblatt, J. E.; Smith, T. F.; Cockerill, F. R.

    1999-01-01

    Recently, a treponema-specific immunoglobulin G (IgG) enzyme immunoassay (EIA), the CAPTIA Syphilis-G (Trinity Biotech, Jamestown, N.Y.), has become available as a diagnostic test for syphilis. A total of 89 stored sera previously tested by the fluorescent treponemal antibody absorption (FTA-ABS) IgG assay were evaluated by the CAPTIA EIA. The FTA-ABS IgG procedure was performed by technologists unblinded to results of rapid plasmid reagin (RPR) testing of the same specimens. Borderline CAPTI...

  14. Hepatitis B virus surface antigen and anti-hepatitis C virus rapid tests underestimate hepatitis prevalence among HIV-infected patients.

    Science.gov (United States)

    Hønge, Bl; Jespersen, S; Medina, C; Té, Ds; da Silva, Zj; Ostergaard, L; Laursen, Al; Wejse, C; Krarup, H; Erikstrup, C

    2014-10-01

    In the case of coinfection with HIV and hepatitis B virus (HBV) and/or hepatitis C virus (HCV), hepatic disease progression is often accelerated, with higher rates of liver cirrhosis and liver-related mortality. We aimed to evaluate the performance of the rapid tests used routinely to detect HBV surface antigen (HBsAg) and anti-HCV among HIV-infected patients in Guinea-Bissau. Blood samples from HIV-infected patients in Guinea-Bissau were stored after testing for HBsAg and anti-HCV with rapid tests. Samples were subsequently re-tested for HBsAg and anti-HCV in Denmark. Two rapid tests were used in Guinea-Bissau: HBsAg Strip Ref 2034 (VEDA.LAB, Alençon, France; sensitivity 62.3%; specificity 99.2%) and HEPA-SCAN (Bhat Bio-Tech, Bangalore, India; sensitivity 57.1%; specificity 99.7%). In the two tests the ability to obtain the correct outcome depended on the antigen and antibody concentrations, respectively. Sex, age, CD4 cell count and antiretroviral therapy status did not differ between false negative and true positive samples in either of the tests. The study is limited by a low number of anti-HCV positive samples. New diagnostic rapid tests should always be evaluated in the setting in which they will be used before implementation. © 2014 British HIV Association.

  15. Clinico-laboratory aspects of anti-nuclear and anti-native DNA antibody tests.

    Science.gov (United States)

    Webb, J

    1978-01-01

    Available techniques for detection of anti-nuclear antibodies are here briefly reviewed. The relatively insensitive LE cell test has been largely supplanted by the indirect immunofluorescent ANA test which should be reported in terms of titre and pattern. Specific measurement of nDNA antibodies is now a regular technique in SLE diagnosis and management.

  16. Metaanalysis of the Performance of a Combined Treponemal and Nontreponemal Rapid Diagnostic Test for Syphilis and Yaws.

    Science.gov (United States)

    Marks, Michael; Yin, Yue-Ping; Chen, Xiang-Sheng; Castro, Arnold; Causer, Louise; Guy, Rebecca; Wangnapi, Regina; Mitjà, Oriol; Aziz, Abdul; Castro, Rita; da Luz Martins Pereira, Filomena; Taleo, Fasihah; Guinard, Jérôme; Bélec, Laurent; Tun, Ye; Bottomley, Christian; Ballard, Ronald C; Mabey, David C W

    2016-09-01

    The human treponematoses are important causes of disease. Mother-to-child transmission of syphilis remains a major cause of stillbirth and neonatal death. There are also almost 100 000 cases of endemic treponemal disease reported annually, predominantly yaws. Rapid diagnostic tests (RDTs) would improve access to screening for these diseases. Most RDTs cannot distinguish current and previous infection. The Dual Path Platform (DPP) Syphilis Screen & Confirm test includes both a treponemal (T1) and nontreponemal (T2) component and may improve the accuracy of diagnosis. We conducted a metaanalysis of published and unpublished evaluations of the DPP-RDT for the diagnosis of syphilis and yaws. We calculated the sensitivity, specificity, and overall agreement of the test compared with reference laboratory tests. Nine evaluations, including 7267 tests, were included. Sensitivity was higher in patients with higher titer rapid plasma reagin (≥1:16) for both the T1 (98.2% vs 90.1%, P syphilis and yaws, although the sensitivity is decreased at lower antibody titers. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America.

  17. A rapid field test for sylvatic plague exposure in wild animals

    Science.gov (United States)

    Abbott, Rachel C.; Hudak, Robert; Mondesire, Roy; Baeten, Laurie A.; Russell, Robin E.; Rocke, Tonie E.

    2014-01-01

    Plague surveillance is routinely conducted to predict future epizootics in wildlife and exposure risk for humans. The most common surveillance method for sylvatic plague is detection of antibodies to Yersinia pestis F1 capsular antigen in sentinel animals, such as coyotes (Canis latrans). Current serologic tests for Y. pestis, hemagglutination (HA) test and enzyme-linked immunosorbent assay (ELISA), are expensive and labor intensive. To address this need, we developed a complete lateral flow device for the detection of specific antibodies to Y. pestis F1 and V antigens. Our test detected anti-F1 and anti-V antibodies in serum and Nobuto filter paper samples from coyotes, and in serum samples from prairie dogs (Cynomys ludovicianus), lynx (Lynx canadensis), and black-footed ferrets (Mustela nigripes). Comparison of cassette results for anti-F1 and anti-V antibodies with results of ELISA or HA tests showed correlations ranging from 0.68 to 0.98. This device provides an affordable, user-friendly tool that may be useful in plague surveillance programs and as a research tool.

  18. Is there a role for antibody testing in the diagnosis of invasive candidiasis?

    Science.gov (United States)

    Quindós, Guillermo; Moragues, María Dolores; Pontón, José

    2004-03-01

    During the last decades, the use of antibody tests for the diagnosis of invasive mycoses has declined as a consequence of the general belief that they are insensitive and non-specific. However, there is a clear evidence that antibodies can be detected in highly immunodeficient patients (such as bone marrow transplant recipients), and that those antibodies are useful for the diagnosis. Antibody tests are currently in use as diagnostic tools for some primary mycoses, such as the endemic mycoses, aspergilloma, allergic bronchopulmonary aspergilosis and sporothrichosis. For invasive candidiasis, diagnostic methods must differentiate Candida colonization of mucous membranes or superficial infection from tissue invasion by this microorganism. Substantial progress has been made in diagnosis of invasive candidiasis with the development of a variety of methods for the detection of antibodies and antigens. However, no single test has found widespread clinical use and there is a consensus that diagnosis based on a single specimen lacks sensitivity. It is necessary to test sequential samples taken while the patient is at greatest risk for developing invasive candidiasis to optimize the diagnosis. Results obtained from a panel of diagnostic tests in association with clinical aspects will likely be the most useful strategy for early diagnosis and therapy.

  19. The fluorescent treponemal antibody-absorption (FTA-ABS) test for syphilis.

    Science.gov (United States)

    Hunter, E F

    1975-01-01

    The FTA test was developed at a time when immunofluorescence procedures were not well-defined. Through technique control and research, a modification of the FTA test, the FTA-ABS, has attained a position as one of the leading treponemal tests to confirm the reagin tests for syphilis. In this review of the FTA-ABS test, attention has been focused on reagent development, with the anticipation that reagent standardization may soon become a reality. The T. pallidum antigen obtained by extracting infected rabbit testicular tissue has evolved from a preparation in which the treponemes remained in the initial extracting fluid to a reagent that can be free of rabbit tissue and globulin. These washed antigen preparations improve visibility of the treponemes on the microscope slide, reduce background fluorescence, and reduce or prevent from occurring nonspecific reactions that are a result of tissue and globulin components. Both washed and nonwashed antigens are available commercially, and, to date, little differentiation has appeared on the product label. The predominant immunoglobulin that reacts with T. pallidum in the indirect fluorescent antibody tests appears to be IgG. This is the major immunoglobulin detected in the FTA-ABS test. IgM, although increased in early syphilis, is also increased in other clinical conditions. Several reports suggest that adult IgM detection in the present FTA-ABS test would be nonspecific. Until specific IgM antibody in adult syphilis can be detected without a risk to test specificity, the conjugate for the FTA-ABS test should continue to be an anti-IgG reagent. Class-specific, anti-IgG reagents are more expensive than other reagents; however, their use may eliminate the problem of nonspecificity resulting from IgM detection. Additionally, micromethods can be used to reduce cost, and this possibility should be investigated. The sorbent that contains an antigen to the Reiter treponeme may or may not specifically absorb the reactivity that

  20. Diagnostic accuracy of tests to detect Hepatitis C antibody: a meta-analysis and review of the literature.

    Science.gov (United States)

    Tang, Weiming; Chen, Wen; Amini, Ali; Boeras, Debi; Falconer, Jane; Kelly, Helen; Peeling, Rosanna; Varsaneux, Olivia; Tucker, Joseph D; Easterbrook, Philippa

    2017-11-01

    Although direct-acting antivirals can achieve sustained virological response rates greater than 90% in Hepatitis C Virus (HCV) infected persons, at present the majority of HCV-infected individuals remain undiagnosed and therefore untreated. While there are a wide range of HCV serological tests available, there is a lack of formal assessment of their diagnostic performance. We undertook a systematic review and meta-analysis to evaluate he diagnostic accuracy of available rapid diagnostic tests (RDT) and laboratory based EIA assays in detecting antibodies to HCV. We used the PRISMA checklist and Cochrane guidance to develop our search protocol. The search strategy was registered in PROSPERO (CRD42015023567). The search focused on hepatitis C, diagnostic tests, and diagnostic accuracy within eight databases (MEDLINE, EMBASE, the Cochrane Central Register of Controlled Trials, Science Citation Index Expanded, Conference Proceedings Citation Index-Science, SCOPUS, Literatura Latino-Americana e do Caribe em Ciências da Saúde and WHO Global Index Medicus. Studies were included if they evaluated an assay to determine the sensitivity and specificity of HCV antibody (HCV Ab) in humans. Two reviewers independently extracted data and performed a quality assessment of the studies using the QUADAS tool. We pooled test estimates using the DerSimonian-Laird method, by using the software R and RevMan. 5.3. A total of 52 studies were identified that included 52,673 unique test measurements. Based on five studies, the pooled sensitivity and specificity of HCV Ab rapid diagnostic tests (RDTs) were 98% (95% CI 98-100%) and 100% (95% CI 100-100%) compared to an enzyme immunoassay (EIA) reference standard. High HCV Ab RDTs sensitivity and specificity were observed across screening populations (general population, high risk populations, and hospital patients) using different reference standards (EIA, nucleic acid testing, immunoblot). There were insufficient studies to undertake

  1. THE INVESTIGATION OF BRUCELLA ANTIBODY WITH MILK RING TEST AND AGGLUTINATION TEST IN MILK COLLECTED FROM SAMSUN REGION

    Directory of Open Access Journals (Sweden)

    Goknur TERZI

    2006-06-01

    Full Text Available In this study Brucella antibodies were investigated with agglutination test (Whey-AT and Milk Ring Test (MRT in a total of 100 milk samples as 50 of cow milk and 50 of goat milk collected from center and villages of Samsun. According to MRT Brucella antibodies was positive at 10 samples (20 % of cow milk and 6 samples (12 % of goat milk. In cow milk, 4 (8 % positive, 3 (6 % suspicious and 43 (86 % negative samples; in goat milk 3 (6 % positive, 2 (4 % suspicious and 45 (90 % negative samples were determined according to antibodies titre of serum agglutination test (Whey-AT. [TAF Prev Med Bull 2006; 5(3.000: 196-203

  2. Rapid Identification of Dengue Virus Serotypes Using Monoclonal Antibodies in an Indirect Immunofluorescence Test.

    Science.gov (United States)

    1982-06-18

    encephalitis(TBH-28), West Nile(E-101), Yellow fever(French neurotropic and 17D strains), and Zika . Two Sandfly Fever viruses (213452 and Candiru) were...were provided as first passage isolates ( Aedes pseudoscutellaris cells, AP-61) or human serum from recent dengue virus patients. African isolates... viruses of the Phlebovirus genus (Table 1). Several monoclonal antibody preparations reacted solely with dengue virus serotypes. Two preparations (13E7 and

  3. Comparison between an immunochromatographic test with an amplified ELISA for detecting e antigen and anti-e antigen antibodies in chronic Hepatitis B

    International Nuclear Information System (INIS)

    Mainet Gonzalez, Damian; Palenzuela Gardon, Daniel O; Aguilar Rubido; Julio C

    2009-01-01

    The disappearance of the e antigen and the appearance of anti-e antigen antibodies are two biomarkers that indicate favorable prognosis in Hepatitis B. In this study the Advanced QualityTM immunochromatographic test for detecting those biomarkers was compared to the Vidas semi-quantitative ELISA test. Our hypothesis was that it is possible to use these biomarkers measured in a rapid and simple Advanced QualityTM immunochromatographic test for evaluating the therapeutic response in clinical trials with chronic hepatitis B patients. The two methods were done following the manufacturer's instructions. The sera were taken from 69 patients with chronic hepatitis B of the clinical trial of the CIGB 440 therapeutic candidate. The immunochromatographic test and ELISA for detecting e antigen and anti-e antigen antibodies presented from substantial to almost perfect agreement in the evaluation of the sera of chronic Hepatitis B patients in a clinical trial. The immunochromatographic test for detecting e antigen had a low positive average agreement and a high negative average agreement compared to the ELISA. Nevertheless, the immunochromatographic test for detecting anti-e antigen antibodies had a high negative and positive average agreement in comparison to the ELISA. The immunochromagraphic test for the e antigen had a lower positive average agreement compared to the ELISA and some patients infected with Hepatitis B virus could not be detected by the former assay. The immunochromatographic test for anti-e antigen antibodies showed a similar performance to that of ELISA and could therefore be used in clinical trials for chronic Hepatitis B in health institutions without the need of a highly qualified lab technician. (author)

  4. Comparative evaluation of two rapid field tests for malaria diagnosis: Partec Rapid Malaria Test® and Binax Now® Malaria Rapid Diagnostic Test.

    Science.gov (United States)

    Nkrumah, Bernard; Acquah, Samuel Ek; Ibrahim, Lukeman; May, Juergen; Brattig, Norbert; Tannich, Egbert; Nguah, Samuel Blay; Adu-Sarkodie, Yaw; Huenger, Frank

    2011-05-23

    About 90% of all malaria deaths in sub-Saharan Africa occur in children under five years. Fast and reliable diagnosis of malaria requires confirmation of the presence of malaria parasites in the blood of patients with fever or history suggestive of malaria; hence a prompt and accurate diagnosis of malaria is the key to effective disease management. Confirmation of malaria infection requires the availability of a rapid, sensitive, and specific testing at an affordable cost. We compared two recent methods (the novel Partec Rapid Malaria Test® (PT) and the Binax Now® Malaria Rapid Diagnostic Test (BN RDT) with the conventional Giemsa stain microscopy (GM) for the diagnosis of malaria among children in a clinical laboratory of a hospital in a rural endemic area of Ghana. Blood samples were collected from 263 children admitted with fever or a history of fever to the pediatric clinic of the Agogo Presbyterian Hospital. The three different test methods PT, BN RDT and GM were performed independently by well trained and competent laboratory staff to assess the presence of malaria parasites. Results were analyzed and compared using GM as the reference standard. In 107 (40.7%) of 263 study participants, Plasmodium sp. was detected by GM. PT and BN RDT showed positive results in 111 (42.2%) and 114 (43.4%), respectively. Compared to GM reference standard, the sensitivities of the PT and BN RDT were 100% (95% CI: 96.6-100) and 97.2% (95% CI: 92.0-99.4), respectively, specificities were 97.4% (95% CI: 93.6-99.3) and 93.6% (95% CI: 88.5-96.9), respectively. There was a strong agreement (kappa) between the applied test methods (GM vs PT: 0.97; p < 0.001 and GM vs BN RDT: 0.90; p < 0.001). The average turnaround time per tests was 17 minutes. In this study two rapid malaria tests, PT and BN RDT, demonstrated a good quality of their performance compared to conventional GM. Both methods require little training, have short turnaround times, are applicable as well as affordable and

  5. Thyroid Antibodies

    Science.gov (United States)

    ... PF4 Antibody Hepatitis A Testing Hepatitis B Testing Hepatitis C Testing HER2/neu Herpes Testing High-sensitivity C-reactive Protein (hs-CRP) Histamine Histone Antibody HIV Antibody and HIV Antigen (p24) HIV Antiretroviral Drug Resistance Testing, Genotypic HIV Viral Load HLA Testing HLA- ...

  6. Antigen detection of rabies virus in brain smear using direct Rapid Immunohistochemistry Test

    Directory of Open Access Journals (Sweden)

    Damayanti R

    2014-03-01

    Full Text Available Rabies is zoonotic disease caused by a fatal, neurotropic virus. Rabies virus is classified into the Genus of Lyssavirus under the yang family of Rhabdoviridae. Rabies affecting hot- blooded animals, as well as human. Dogs, cats, monkeys are the vectors or reservoirs for rabies and the virus was transmitted through the saliva after infected animal’s bites. The aim of this study was to conduct rapid diagnosis to detect rabies viral antigen in brain smear using immunohistochemical (IHC method namely direct Rapid Immunohistochemical Test (dRIT. A total number of 119 brain samples were achieved from Bukittinggi Veterinary Laboratory, West Sumatra. Standardisation and validation of the method were compared to Fluorescent Antibody Test (FAT as a golden standard for rabies diagnosis. Results show that dRIT was a very good method, it can be performed within two hours without the need of fluorescent microscope. The samples were tested using FAT and from 119 samples tested, 80 (67.23% samples were positive for rabies and 39 (32.77% samples were negative for rabies whereas using dRIT showed that 78 (65.54% samples were positive for rabies and 41 (34.45% samples were negative for rabies. The dRIT results were validated by comparing them with FAT results as a golden standard for rabies. The relative sensitivity of dRIT to FAT was 97.5% and the relative specificity to FAT was 100% (with Kappa value of 0.976, stated as excellent. The achievement showed that dRIT is very potential diagnostic tool and is highly recommended to be used widely as a rapid diagnosis tool for rabies.

  7. H5N1-SeroDetect EIA and rapid test: a novel differential diagnostic assay for serodiagnosis of H5N1 infections and surveillance.

    Science.gov (United States)

    Khurana, Surender; Sasono, Pretty; Fox, Annette; Nguyen, Van Kinh; Le, Quynh Mai; Pham, Quang Thai; Nguyen, Tran Hien; Nguyen, Thanh Liem; Horby, Peter; Golding, Hana

    2011-12-01

    Continuing evolution of highly pathogenic (HP) H5N1 influenza viruses in wild birds with transmission to domestic poultry and humans poses a pandemic threat. There is an urgent need for a simple and rapid serological diagnostic assay which can differentiate between antibodies to seasonal and H5N1 strains and that could provide surveillance tools not dependent on virus isolation and nucleic acid technologies. Here we describe the establishment of H5N1 SeroDetect enzyme-linked immunosorbent assay (ELISA) and rapid test assays based on three peptides in HA2 (488-516), PB1-F2 (2-75), and M2e (2-24) that are highly conserved within H5N1 strains. These peptides were identified by antibody repertoire analyses of H5N1 influenza survivors in Vietnam using whole-genome-fragment phage display libraries (GFPDLs). To date, both platforms have demonstrated high levels of sensitivity and specificity in detecting H5N1 infections (clade 1 and clade 2.3.4) in Vietnamese patients as early as 7 days and up to several years postinfection. H5N1 virus-uninfected individuals in Vietnam and the United States, including subjects vaccinated with seasonal influenza vaccines or with confirmed seasonal virus infections, did not react in the H5N1-SeroDetect assays. Moreover, sera from individuals vaccinated with H5N1 subunit vaccine with moderate anti-H5N1 neutralizing antibody titers did not react positively in the H5N1-SeroDetect ELISA or rapid test assays. The simple H5N1-SeroDetect ELISA and rapid tests could provide an important tool for large-scale surveillance for potential exposure to HP H5N1 strains in both humans and birds.

  8. Evaluation of a new rapid lateral flow chromatography test for the diagnosis of Helicobacter Pylori

    International Nuclear Information System (INIS)

    Kaklikkaya, N.; Dinc, U.; Dabanca, Pinar A.; Aydin, F.; Erturk, M.; Akdogan, Remzi A.; Ozgur, O.; Uzun, Dogan Y.; Gungor, E.; Arslan, M.; Cobanoglu, U.

    2006-01-01

    The rapid, simple and non-invasive diagnosis of Helicobacter pylori (H. pylori) infection is important in implementing chemotherapy in appropriate manner, and in assessing persistent H. pylori infection after eradication therapy. The Immuno Card STAT HpSA kit (Meridian Bioscience, Europe) is a lateral flow chromatography test which utilizes a monoclonal anti-H. pylori antibody. In this study, we investigated the usefulness of the ImmunoCard STAT HpSA test before and after eradication therapy on patients referred to undergo upper gastrointestinal endoscopy. Sixty-five consecutive patients who were referred to undergo upper gastrointestinal endoscopy at the Department of Gastroenterology, Karadeniz Technical University Medical School, Turkey between February and August 2005 were included in this study. The ImmunoCard STAT HpSA was compared with 4 invasive tests (histology, gram staining, rapid urease test, and culture). The reference method was defined as positive when 2 of the 4 invasive tests were positive. A negative H. pylori status was considered when all 4 tests present concordant negative results. Overall, the ImmunoCard STAT HpSA test had 77.8% sensitivity, 79.3% specificity, 82.4% positive predictive value (PPV) and 74.2% negative predictive value (NPV) in all patients. With regard to pre-treatment values, the sensitivity was 70.6%, specificity 70.6%, PPV 100% and NPV 100% while on post-treatment group the sensitivity was 84.2%, specificity 64.7%, PPV 72.7% and NPV 78.6%. Our results indicate that the ImmunoCard STAT HpSA test is a rapid, simple, and helpful procedure not only to determine H. pylori infection but also to assess the success of eradication therapy. (author)

  9. [Detection of anti-Leptospira antibodies in sera of patients in the latex agglutination test].

    Science.gov (United States)

    Volina, E G; Sarukhanova, L E; Iashina, N V; Prokopov, N I; Shkarlat, P E; Barysheva, I V

    2001-01-01

    The results of the preliminary evaluation of the sensitivity and specificity of the newly developed diagnostic test based on the determination of genus-specific antibodies to leptospires in the latex agglutination test, are presented. This test makes it possible to detect anti-Leptospira antibodies of any serogroup. The advantages of the developed test have been determined.

  10. The use of monoclonal antibodies in competitive ELISA for the detection of antibodies to rinderpest and peste des petits ruminants viruses

    International Nuclear Information System (INIS)

    Anderson, J.; McKay, J.A.; Butcher, R.N.

    1991-01-01

    A monoclonal antibody against the haemagglutinin of rinderpest virus has been used in a competitive ELISA (C-ELISA) for the detection of antibodies to rinderpest virus in cattle, sheep, goat and game sera. Unlike the indirect ELISA and the virus neutralisation test (VNT), the C-ELISA detects only antibodies to rinderpest virus and gives no cross-reactivity with antibodies to peste des petits ruminants (PPR) virus. Antibodies to a wide range of strains of rinderpest virus have been detected using this assay, suggesting its suitability for both sero-monitoring and sero-surveillance. Analysis of C-ELISA results from the examination of field sera shows a much greater separation of negative and positive populations as compared to the indirect ELISA. A further monoclonal antibody against the H protein of PPR has also been found suitable for use in a C-ELISA for the detection of antibodies to PPR virus. The use of these two C-ELISA's has made possible rapid differential sero-diagnosis without recourse to cross-VNT testing. The use of monoclonal antibody-based assays will allow much greater standardisation of rinderpest and PPR diagnosis, and following field-trials the C-ELISA will replace the indirect ELISA for sero-monitoring throughout the Pan African Rinderpest Campaign. (author). 3 refs, 6 figs, 1 tab

  11. Detection of IgE insulin antibody with radioallergosorbent test

    Energy Technology Data Exchange (ETDEWEB)

    Nakagawa, S; Nakayama, H; Sasaki, T; Watanabe, T; Aoki, S [Hokkaido Univ., Sapporo (Japan). 2. Dept. of Medicine; Saito, N [Sapporo Railway Hospital (Japan). Dept. of Medicine

    1978-01-01

    An in vitro method for detecting IgE insulin antibody using the principle of the radioallergosorbent test (RAST) is described. In six patients with insulin allergy, the RAST values were higher than in normal persons or insulin-treated diabetics without insulin allergy. No differences were observed between normal persons and insulin-treated diabetics without insulin allergy. Moreover, it was observed that in one patient treated with highly purified insulin, there was a gradual decrease of RAST value parallel to the radioinsulin binding activity and clinical allergic symptoms. The RAST value of insulin is slightly inhibited by non-IgE antibodies and is, therefore, a semiquantitative value. However, the RAST is simple to perform and reproducible; it is therefore very useful in the detection of IgE insulin antibodies.

  12. Detection of IgE insulin antibody with radioallergosorbent test

    International Nuclear Information System (INIS)

    Nakagawa, S.; Nakayama, H.; Sasaki, T.; Watanabe, T.; Aoki, S.; Saito, N.

    1978-01-01

    An in vitro method for detecting IgE insulin antibody using the principle of the radioallergosorbent test (RAST) is described. In six patients with insulin allergy, the RAST values were higher than in normal persons or insulin-treated diabetics without insulin allergy. No differences were observed between normal persons and insulin-treated diabetics without insulin allergy. Moreover, it was observed that in one patient treated with highly purified insulin, there was a gradual decrease of RAST value parallel to the radioinsulin binding activity and clinical allergic symptoms. The RAST value of insulin is slightly inhibited by non-IgE antibodies and is, therefore, a semiquantitative value. However, the RAST is simple to perform and reproducible; it is therefore very useful in the detection of IgE insulin antibodies. (orig.) [de

  13. Development of Colloidal Gold-Based Immunochromatographic Assay for Rapid Detection of Goose Parvovirus

    Directory of Open Access Journals (Sweden)

    Xianglong Yu

    2018-05-01

    Full Text Available Goose parvovirus (GPV remains as a worldwide problem in goose industry. For this reason, it is necessary to develop a new diagnostic approach that is easier and faster than conventional tests. A rapid immunochromatographic assay based on antibody colloidal gold nanoparticles specific to GPV was developed for the detection of GPV in goose allantoic fluid and supernatant of tissue homogenate. The monoclonal antibodies (Mab was produced by immunizing the BALB/c mice with purified GPV suspension, and the polyclonal antibody (pAb was produced by immunizing the rabbits with recombinant VP3 protein. The colloidal gold was prepared by the reduction of gold salt with sodium citrate coupled with Mab against GPV. The optimal concentrations of the coating antibody and capture antibody were determined to be 1.6 mg/ml and 9 μg/ml. With visual observation, the lower limit was found to be around 1.2 μg/ml. Common diseases of goose were tested to evaluate the specificity of the immune colloidal gold (ICG strip, and no cross-reaction was observed. The clinical detection was examined by carrying out the ICG strip test with 92 samples and comparing the results of these tests with those obtained via agar diffusion test and polymerase chain reaction (PCR test. Therefore, the ICG strip test was a sufficiently sensitive and accurate detection method for a rapid screening of GPV.

  14. Development of a dipstick assay for detection of Leishmania-specific canine antibodies

    NARCIS (Netherlands)

    Schallig, Henk D. F. H.; Cardoso, Luís; Hommers, Marieke; Kroon, Nel; Belling, Guus; Rodrigues, Manuela; Semião-Santos, Saul J.; Vetter, Hans

    2004-01-01

    A dipstick assay, based on Leishmania infantum antigen, for the rapid detection of Leishmania-specific antibodies in canine serum samples was developed and evaluated. After determination of optimal dipstick test conditions, test performance was compared with two existing serological tests, i.e., the

  15. Accuracy of individual rapid tests for serodiagnosis of gambiense sleeping sickness in West Africa.

    Directory of Open Access Journals (Sweden)

    Vincent Jamonneau

    2015-02-01

    Full Text Available Individual rapid tests for serodiagnosis (RDT of human African trypanosomiasis (HAT are particularly suited for passive screening and surveillance. However, so far, no large scale evaluation of RDTs has been performed for diagnosis of Trypanosoma brucei gambiense HAT in West Africa. The objective of this study was to assess the diagnostic accuracy of 2 commercial HAT-RDTs on stored plasma samples from West Africa.SD Bioline HAT and HAT Sero-K-Set were performed on 722 plasma samples originating from Guinea and Côte d'Ivoire, including 231 parasitologically confirmed HAT patients, 257 healthy controls, and 234 unconfirmed individuals whose blood tested antibody positive in the card agglutination test but negative by parasitological tests. Immune trypanolysis was performed as a reference test for trypanosome specific antibody presence. Sensitivities in HAT patients were respectively 99.6% for SD Bioline HAT, and 99.1% for HAT Sero-K-Set, specificities in healthy controls were respectively 87.9% and 88.3%. Considering combined positivity in both RDTs, increased the specificity significantly (p ≤ 0.0003 to 93.4%, while 98.7% sensitivity was maintained. Specificities in controls were 98.7-99.6% for the combination of one or two RDTs with trypanolysis, maintaining a sensitivity of at least 98.1%.The observed specificity of the single RDTs was relatively low. Serial application of SD Bioline HAT and HAT Sero-K-Set might offer superior specificity compared to a single RDT, maintaining high sensitivity. The combination of one or two RDTs with trypanolysis seems promising for HAT surveillance.

  16. Rapid polyclonal desensitization with antibodies to IgE and FcεRIα.

    Science.gov (United States)

    Khodoun, Marat V; Kucuk, Zeynep Yesim; Strait, Richard T; Krishnamurthy, Durga; Janek, Kevin; Lewkowich, Ian; Morris, Suzanne C; Finkelman, Fred D

    2013-06-01

    Rapid desensitization, a procedure in which persons allergic to an antigen are treated at short intervals with increasing doses of that antigen until they tolerate a large dose, is an effective, but risky, way to induce temporary tolerance. We wanted to determine whether this approach can be adapted to suppress all IgE-mediated allergies in mice by injecting serially increasing doses of monoclonal antibodies (mAbs) to IgE or FcεRIα. Active and passive models of antigen- and anti-IgE mAb-induced IgE-mediated anaphylaxis were used. Mice were desensitized with serially increasing doses of anti-IgE mAb, anti-FcεRIα mAb, or antigen. Development of shock (hypothermia), histamine and mast cell protease release, cytokine secretion, calcium flux, and changes in cell number and FcεRI and IgE expression were evaluated. Rapid desensitization with anti-IgE mAb suppressed IgE-mediated immediate hypersensitivity; however, some mice developed mild anaphylaxis during desensitization. Rapid desensitization with anti-FcεRIα mAb that only binds FcεRI that is not occupied by IgE suppressed both active and passive IgE-mediated anaphylaxis without inducing disease. It quickly, but temporarily, suppressed IgE-mediated anaphylaxis by decreasing mast cell signaling through FcεRI, then slowly induced longer lasting mast cell unresponsiveness by removing membrane FcεRI. Rapid desensitization with anti-FcεRIα mAb was safer and longer lasting than rapid desensitization with antigen. A rapid desensitization approach with anti-FcεRIα mAb safely desensitizes mice to IgE-mediated anaphylaxis by inducing mast cell anergy and later removing all mast cell IgE. Rapid desensitization with an anti-human FcεRIα mAb may be able to prevent human IgE-mediated anaphylaxis. Copyright © 2013 American Academy of Allergy, Asthma & Immunology. Published by Mosby, Inc. All rights reserved.

  17. Screening for transfusion transmissible infections using rapid diagnostic tests in Africa: a potential hazard to blood safety?

    Science.gov (United States)

    Prugger, C.; Laperche, S.; Murphy, E. L.; Bloch, E. M.; Kaidarova, Z.; Tafflet, M.; Lefrère, J.-J.; Jouven, X.

    2016-01-01

    Rapid diagnostic tests (RDTs) are routinely used in African blood centres. We analysed data from two cross-sectional studies representing 95 blood centres in 29 African countries. Standardized panels of sera containing varying concentrations of anti-human immunodeficiency virus (HIV) antibodies (Ab), hepatitis B virus antigen (HBsAg) and antihepatitis C virus (HCV) Ab were screened using routine operational testing procedures at the centres. Sensitivity of detection using RDTs was high for HIV Ab-positive samples, but low for intermediately HBsAg (51·5%) and HCV Ab (40·6%)-positive samples. These findings suggest that current RDT use in Africa could pose a hazard to blood safety. PMID:26646317

  18. An Integrated Solution-Based Rapid Sample Preparation Procedure for the Analysis of N-Glycans From Therapeutic Monoclonal Antibodies.

    Science.gov (United States)

    Aich, Udayanath; Liu, Aston; Lakbub, Jude; Mozdzanowski, Jacek; Byrne, Michael; Shah, Nilesh; Galosy, Sybille; Patel, Pramthesh; Bam, Narendra

    2016-03-01

    Consistent glycosylation in therapeutic monoclonal antibodies is a major concern in the biopharmaceutical industry as it impacts the drug's safety and efficacy and manufacturing processes. Large numbers of samples are created for the analysis of glycans during various stages of recombinant proteins drug development. Profiling and quantifying protein N-glycosylation is important but extremely challenging due to its microheterogeneity and more importantly the limitations of existing time-consuming sample preparation methods. Thus, a quantitative method with fast sample preparation is crucial for understanding, controlling, and modifying the glycoform variance in therapeutic monoclonal antibody development. Presented here is a rapid and highly quantitative method for the analysis of N-glycans from monoclonal antibodies. The method comprises a simple and fast solution-based sample preparation method that uses nontoxic reducing reagents for direct labeling of N-glycans. The complete work flow for the preparation of fluorescently labeled N-glycans takes a total of 3 h with less than 30 min needed for the release of N-glycans from monoclonal antibody samples. Copyright © 2016 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  19. Rapid diagnostic tests for diagnosing uncomplicated non-falciparum or Plasmodium vivax malaria in endemic countries

    Science.gov (United States)

    Abba, Katharine; Kirkham, Amanda J; Olliaro, Piero L; Deeks, Jonathan J; Donegan, Sarah; Garner, Paul; Takwoingi, Yemisi

    2014-01-01

    Background In settings where both Plasmodium vivax and Plasmodium falciparum infection cause malaria, rapid diagnostic tests (RDTs) need to distinguish which species is causing the patients' symptoms, as different treatments are required. Older RDTs incorporated two test lines to distinguish malaria due to P. falciparum, from malaria due to any other Plasmodium species (non-falciparum). These RDTs can be classified according to which antibodies they use: Type 2 RDTs use HRP-2 (for P. falciparum) and aldolase (all species); Type 3 RDTs use HRP-2 (for P. falciparum) and pLDH (all species); Type 4 use pLDH (fromP. falciparum) and pLDH (all species). More recently, RDTs have been developed to distinguish P. vivax parasitaemia by utilizing a pLDH antibody specific to P. vivax. Objectives To assess the diagnostic accuracy of RDTs for detecting non-falciparum or P. vivax parasitaemia in people living in malaria-endemic areas who present to ambulatory healthcare facilities with symptoms suggestive of malaria, and to identify which types and brands of commercial test best detect non-falciparum and P. vivax malaria. Search methods We undertook a comprehensive search of the following databases up to 31 December 2013: Cochrane Infectious Diseases Group Specialized Register; MEDLINE; EMBASE; MEDION; Science Citation Index; Web of Knowledge; African Index Medicus; LILACS; and IndMED. Selection criteria Studies comparing RDTs with a reference standard (microscopy or polymerase chain reaction) in blood samples from a random or consecutive series of patients attending ambulatory health facilities with symptoms suggestive of malaria in non-falciparum endemic areas. Data collection and analysis For each study, two review authors independently extracted a standard set of data using a tailored data extraction form. We grouped comparisons by type of RDT (defined by the combinations of antibodies used), and combined in meta-analysis where appropriate. Average sensitivities and

  20. Comparisons of Venezuelan encephalitis virus strains by hemagglutination-inhibition tests with chicken antibodies.

    Science.gov (United States)

    Scherer, W F; Pancake, B A

    1977-01-01

    Twenty strains of Venezuelan encephalitis (VE) virus inoculated intravenously in large doses into roosters produced hemagglutination-inhibition (HI) antibodies detectable in plasmas within 7 to 10 days. No signs of illness occurred, and there was no evidence of viral growth in tissues since blood concentrations of infectious virus steadily decreased after inoculation. HI antibodies in early plasmas were specific for VE virus and did not cross-react significantly with two other North American alphaviruses, eastern and western encephalitis viruses. VE virus strains could be distinquished by virus-dilution, short-incubation HI, but not by plasma-dilution neutralization tests, by using early rooster antibodies. The distinctions by HI test were similar with some strains to, but different with other strains from, those described by Young and Johnson with the spiny rat antisera used to establish their subtype classifications of VE virus (14, 28). Nevertheless, results of HI tests with rooster antibodies correlated with equine virulence, as did results with spiny rat antibodies, and distinguished the new strains of virus that appeared in Middle America during the VE outbreak of 1969 from preexisting strains. PMID:591629

  1. A rapid and quantitative assay for measuring antibody-mediated neutralization of West Nile virus infection

    International Nuclear Information System (INIS)

    Pierson, Theodore C.; Sanchez, Melissa D.; Puffer, Bridget A.; Ahmed, Asim A.; Geiss, Brian J.; Valentine, Laura E.; Altamura, Louis A.; Diamond, Michael S.; Doms, Robert W.

    2006-01-01

    West Nile virus (WNV) is a neurotropic flavivirus within the Japanese encephalitis antigenic complex that is responsible for causing West Nile encephalitis in humans. The surface of WNV virions is covered by a highly ordered icosahedral array of envelope proteins that is responsible for mediating attachment and fusion with target cells. These envelope proteins are also primary targets for the generation of neutralizing antibodies in vivo. In this study, we describe a novel approach for measuring antibody-mediated neutralization of WNV infection using virus-like particles that measure infection as a function of reporter gene expression. These reporter virus particles (RVPs) are produced by complementation of a sub-genomic replicon with WNV structural proteins provided in trans using conventional DNA expression vectors. The precision and accuracy of this approach stem from an ability to measure the outcome of the interaction between antibody and viral antigens under conditions that satisfy the assumptions of the law of mass action as applied to virus neutralization. In addition to its quantitative strengths, this approach allows the production of WNV RVPs bearing the prM-E proteins of different WNV strains and mutants, offering considerable flexibility for the study of the humoral immune response to WNV in vitro. WNV RVPs are capable of only a single round of infection, can be used under BSL-2 conditions, and offer a rapid and quantitative approach for detecting virus entry and its inhibition by neutralizing antibody

  2. Rapid Detection of the Varicella Zoster Virus

    Science.gov (United States)

    Lewis, Michelle P.; Harding, Robert

    2011-01-01

    1.Technology Description-Researchers discovered that when the Varicella Zoster Virus (VZV) reactivates from latency in the body, the virus is consistently present in saliva before the appearance of skin lesions. A small saliva sample is mixed with a specialized reagent in a test kit. If the virus is present in the saliva sample, the mixture turns a red color. The sensitivity and specificity emanates from an antibody-antigen reaction. This technology is a rapid, non-invasive, point of-of-care testing kit for detecting the virus from a saliva sample. The device is easy to use and can be used in clinics and in remote locations to quickly detect VZV and begin treatment with antiviral drugs. 2.Market Opportunity- RST Bioscience will be the first and only company to market a rapid, same day test kit for the detection of VZV in saliva. The RST detection test kit will have several advantages over existing, competitive technology. The test kit is self contained and laboratory equipment is not required for analysis of the sample. Only a single saliva sample is required to be taken instead of blood or cerebral spinal fluid. The test kit is portable, sterile and disposable after use. RST detection test kits require no electrical power or expensive storage equipment and can be used in remote locations. 3.Market Analysis- According to the CDC, it is estimated that 1 million cases of shingles occur each year in the U.S. with more than half over the age of sixty. There is a high demand for rapid diagnostics by the public. The point-of-care testing (POCT) market is growing faster than other segments of in vitro diagnostics. According to a July 2007 InteLab Corporation industry report the overall market for POCT was forecast to increase from $10.3 billion in 2005 to $18.7 billion by 2011. The market value of this test kit has not been determined. 4.Competition- The VZV vaccine prevents 50% of cases and reduces neuralgia by 66%. The most popular test detects VZV-specific IgM antibody

  3. Evaluation of seven rapid tests for syphilis available in Brazil using defibrinated plasma panels.

    Science.gov (United States)

    Bazzo, Maria Luiza; da Motta, Leonardo Rapone; Rudolf-Oliveira, Renata Cristina Messores; Bigolin, Alisson; Golfetto, Lisléia; Mesquita, Fábio; Benzaken, Adele Schwartz; Gaspar, Pamela Cristina; Pires, Ana Flavia Nacif P Coelho; Ferreira Júnior, Orlando da Costa; Franchini, Miriam

    2017-12-01

    In 2012, the WHO estimated that 6 million new cases of syphilis per year would occur worldwide, including 937 000 in Brazil. Early diagnosis and treatment of syphilis are essential to reduce morbidity and prevent transmission. The availability of rapid tests (RTs) for this diagnosis means that testing can be performed more quickly, as a point-of-care test, even in non-laboratory environments and requires only simple technical training to antibodies detection. The objective of this study was to evaluate the performance and operational aspects of seven commercially available RTs for syphilis in Brazil. Seven rapid treponemal tests were evaluated for sensitivity, specificity, accuracy and Kappa value, according to a panel composed of 493 members. The operational performance of the assay was also determined for these tests. The seven RTs showed sensitivity ranging from 94.5% to 100% when compared with the reference tests and specificity of between 91.5% and 100%. All the RTs evaluated presented good operational performance, and only one failed to present the minimum specificity as defined by Brazil's Ministry of Health. All the tests presented good operational performance, and the professionals who performed them considered them to be easy to use and interpret. This evaluation is important for making informed choices of tests to be used in the Brazilian Unified Health System. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  4. A rapid microassay for detecting antibodies against poliovirus based on [14C]thymidine uptake of treated cell cultures

    International Nuclear Information System (INIS)

    Hilfenhaus, J.; Damm, H.; Ziegelmaier, R.; Gruschkau, H.

    1977-01-01

    DNA synthesis of mammalian cells propagated in microplates can easily be measured if cell cultures incubated with [ 14 C]thymidine are harvested on to glass fibre filters by a semiautomatic harvesting technique. Soon after infection with poliovirus, [ 14 C]thymidine uptake of U cells (established, human amniotic cell line) is inhibited. This inhibition can be prevented by previous virus neutralization with antibody. Based on this effect a rapid, precise assay method was set up to determine neutralizing antibody titres against poliovirus. There was a good correlation between titres obtained by this assay and those obtained by 50% endpoint titrations in cytopathogenic effect inhibition assays

  5. Development and clinical evaluation of a rapid diagnostic kit for feline leukemia virus infection.

    Science.gov (United States)

    Kim, Won-Shik; Chong, Chom-Kyu; Kim, Hak-Yong; Lee, Gyu-Cheol; Jeong, Wooseog; An, Dong-Jun; Jeoung, Hye-Young; Lee, Jae-In; Lee, Young-Ki

    2014-01-01

    Feline leukemia virus (FeLV) causes a range of neoplastic and degenerative diseases in cats. To obtain a more sensitive and convenient diagnosis of the disease, we prepared monoclonal antibodies specific for the FeLV p27 to develop a rapid diagnostic test with enhanced sensitivity and specificity. Among these antibodies, we identified two clones (hybridomas 8F8B5 and 8G7D1) that specifically bound to FeLV and were very suitable for a diagnostic kit. The affinity constants for 8F8B5 and 8G7D1 were 0.35 × 10⁸ and 0.86 × 10⁸, respectively. To investigate the diagnostic abilities of the rapid kit using these antibodies, we performed several clinical studies. Assessment of analytical sensitivity revealed that the detection threshold of the rapid diagnostic test was 2 ng/mL for recombinant p27 and 12.5 × 10⁴ IU/mL for FeLV. When evaluating 252 cat sera samples, the kit was found to have a kappa value of 0.88 compared to polymerase chain reaction (PCR), indicating a significant correlation between data from the rapid diagnostic test and PCR. Sensitivity and specificity of the kit were 95.2% (20/21) and 98.5% (257/261), respectively. Our results demonstrated that the rapid diagnostic test would be a suitable diagnostic tool for the rapid detection of FeLV infection in cats.

  6. Highly sensitive multianalyte immunochromatographic test strip for rapid chemiluminescent detection of ractopamine and salbutamol

    International Nuclear Information System (INIS)

    Gao, Hongfei; Han, Jing; Yang, Shijia; Wang, Zhenxing; Wang, Lin; Fu, Zhifeng

    2014-01-01

    Graphical abstract: A multianalyte immunochromatographic test strip was developed for the rapid detection of two β 2 -agonists. Due to the application of chemiluminescent detection, this quantitative method shows much higher sensitivity. - Highlights: • An immunochromatographic test strip was developed for detection of multiple β 2 -agonists. • The whole assay process can be completed within 20 min. • The proposed method shows much higher sensitivity due to the application of CL detection. • It is a portable analytical tool suitable for field analysis and rapid screening. - Abstract: A novel immunochromatographic assay (ICA) was proposed for rapid and multiple assay of β 2 -agonists, by utilizing ractopamine (RAC) and salbutamol (SAL) as the models. Owing to the introduction of chemiluminescent (CL) approach, the proposed protocol shows much higher sensitivity. In this work, the described ICA was based on a competitive format, and horseradish peroxidase-tagged antibodies were used as highly sensitive CL probes. Quantitative analysis of β 2 -agonists was achieved by recording the CL signals of the probes captured on the two test zones of the nitrocellulose membrane. Under the optimum conditions, RAC and SAL could be detected within the linear ranges of 0.50–40 and 0.10–50 ng mL −1 , with the detection limits of 0.20 and 0.040 ng mL −1 (S/N = 3), respectively. The whole process for multianalyte immunoassay of RAC and SAL can be completed within 20 min. Furthermore, the test strip was validated with spiked swine urine samples and the results showed that this method was reliable in measuring β 2 -agonists in swine urine. This CL-based multianalyte test strip shows a series of advantages such as high sensitivity, ideal selectivity, simple manipulation, high assay efficiency and low cost. Thus, it opens up new pathway for rapid screening and field analysis, and shows a promising prospect in food safety

  7. Highly sensitive multianalyte immunochromatographic test strip for rapid chemiluminescent detection of ractopamine and salbutamol

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Hongfei; Han, Jing; Yang, Shijia; Wang, Zhenxing; Wang, Lin; Fu, Zhifeng, E-mail: fuzf@swu.edu.cn

    2014-08-11

    Graphical abstract: A multianalyte immunochromatographic test strip was developed for the rapid detection of two β{sub 2}-agonists. Due to the application of chemiluminescent detection, this quantitative method shows much higher sensitivity. - Highlights: • An immunochromatographic test strip was developed for detection of multiple β{sub 2}-agonists. • The whole assay process can be completed within 20 min. • The proposed method shows much higher sensitivity due to the application of CL detection. • It is a portable analytical tool suitable for field analysis and rapid screening. - Abstract: A novel immunochromatographic assay (ICA) was proposed for rapid and multiple assay of β{sub 2}-agonists, by utilizing ractopamine (RAC) and salbutamol (SAL) as the models. Owing to the introduction of chemiluminescent (CL) approach, the proposed protocol shows much higher sensitivity. In this work, the described ICA was based on a competitive format, and horseradish peroxidase-tagged antibodies were used as highly sensitive CL probes. Quantitative analysis of β{sub 2}-agonists was achieved by recording the CL signals of the probes captured on the two test zones of the nitrocellulose membrane. Under the optimum conditions, RAC and SAL could be detected within the linear ranges of 0.50–40 and 0.10–50 ng mL{sup −1}, with the detection limits of 0.20 and 0.040 ng mL{sup −1} (S/N = 3), respectively. The whole process for multianalyte immunoassay of RAC and SAL can be completed within 20 min. Furthermore, the test strip was validated with spiked swine urine samples and the results showed that this method was reliable in measuring β{sub 2}-agonists in swine urine. This CL-based multianalyte test strip shows a series of advantages such as high sensitivity, ideal selectivity, simple manipulation, high assay efficiency and low cost. Thus, it opens up new pathway for rapid screening and field analysis, and shows a promising prospect in food safety.

  8. Purification of immunoreactive radiolabeled moniclonal antibodies with anti-iodiotypic moniclonal antibodies

    International Nuclear Information System (INIS)

    Temponi, M.; Pupa, S.; Ferrone, S.

    1990-01-01

    A method is described to purify immunoreactive moniclonal antibodies from radiolabeled monoclonal antibody preparations. The method is based on incubation of radiolabeled monoclonal antibodies with insolubilized anti-idiotypic monoclonal antibodies to idiotopes within the antigen-combining site of monoclonal antibodies to be purified an elution of bound monoclonal antibodies with a low pH buffer. The immunoreactive fraction of the purified monoclonal antibodies was at least 82%; the yeald was at least 73%. The purification procedure did not cause any detectable change in the affinity constant of the eluted monoclonal antibodies. The method is simple and rapid; the requirement for anti-idiotypic monoclonal antibodies to idiotopes within the antigen-combining site of the antibodies to be purified is not likely to represent a major limitation in the broad application of the present method, since the hybridoma technology has greatly facilitated the development of anti-idiotypic monoclonal antibodies. (author). 12 refs.; 4 figs.; 1 tab

  9. Evaluation of the clinical utility of a rapid blood test for human leptospirosis

    NARCIS (Netherlands)

    Eapen, C. K.; Sugathan, Sheela; Kuriakose, Mariamma; Abdoel, Theresia; Smits, Henk L.

    2002-01-01

    A rapid assay device for the detection of Leptospira-specific immunoglobulin M (IgM) antibodies was applied on whole blood samples collected from a group of consecutive patients admitted with clinical suspicion of leptospirosis to a district hospital in Kerala, India. The hospital is located in an

  10. A novel non-rapid-eye movement and rapid-eye-movement parasomnia with sleep breathing disorder associated with antibodies to IgLON5: a case series, characterisation of the antigen, and post-mortem study.

    Science.gov (United States)

    Sabater, Lidia; Gaig, Carles; Gelpi, Ellen; Bataller, Luis; Lewerenz, Jan; Torres-Vega, Estefanía; Contreras, Angeles; Giometto, Bruno; Compta, Yaroslau; Embid, Cristina; Vilaseca, Isabel; Iranzo, Alex; Santamaría, Joan; Dalmau, Josep; Graus, Francesc

    2014-06-01

    Autoimmunity might be associated with or implicated in sleep and neurodegenerative disorders. We aimed to describe the features of a novel neurological syndrome associated with prominent sleep dysfunction and antibodies to a neuronal antigen. In this observational study, we used clinical and video polysomnography to identify a novel sleep disorder in three patients referred to the Sleep Unit of Hospital Clinic, University of Barcelona, Spain, for abnormal sleep behaviours and obstructive sleep apnoea. These patients had antibodies against a neuronal surface antigen, which were also present in five additional patients referred to our laboratory for antibody studies. These five patients had been assessed with polysomnography, which was done in our sleep unit in one patient and the recording reviewed in a second patient. Two patients underwent post-mortem brain examination. Immunoprecipitation and mass spectrometry were used to characterise the antigen and develop an assay for antibody testing. Serum or CSF from 298 patients with neurodegenerative, sleep, or autoimmune disorders served as control samples. All eight patients (five women; median age at disease onset 59 years [range 52-76]) had abnormal sleep movements and behaviours and obstructive sleep apnoea, as confirmed by polysomnography. Six patients had chronic progression with a median duration from symptom onset to death or last visit of 5 years (range 2-12); in four the sleep disorder was the initial and most prominent feature, and in two it was preceded by gait instability followed by dysarthria, dysphagia, ataxia, or chorea. Two patients had a rapid progression with disequilibrium, dysarthria, dysphagia, and central hypoventilation, and died 2 months and 6 months, respectively, after symptom onset. In five of five patients, video polysomnography showed features of obstructive sleep apnoea, stridor, and abnormal sleep architecture (undifferentiated non-rapid-eye-movement [non-REM] sleep or poorly structured

  11. Rapid Aminoglycoside NP Test for Rapid Detection of Multiple Aminoglycoside Resistance in Enterobacteriaceae.

    Science.gov (United States)

    Nordmann, Patrice; Jayol, Aurélie; Dobias, Jan; Poirel, Laurent

    2017-04-01

    The rapid aminoglycoside NP (Nordmann/Poirel) test was developed to rapidly identify multiple aminoglycoside (AG) resistance in Enterobacteriaceae It is based on the detection of the glucose metabolism related to enterobacterial growth in the presence of a defined concentration of amikacin plus gentamicin. Formation of acid metabolites was evidenced by a color change (orange to yellow) of the red phenol pH indicator. The rapid aminoglycoside NP test was evaluated by using bacterial colonies of 18 AG-resistant isolates producing 16S rRNA methylases, 20 AG-resistant isolates expressing AG-modifying enzymes (acetyl-, adenyl-, and phosphotransferases), and 10 isolates susceptible to AG. Its sensitivity and specificity were 100% and 97%, respectively, compared to the broth dilution method, which was taken as the gold standard for determining aminoglycoside resistance. The test is inexpensive, rapid (<2 h), and implementable worldwide. Copyright © 2017 American Society for Microbiology.

  12. A radioimmunoassay method for the rapid detection of Candida antibodies is experimental systematic candidiasis

    International Nuclear Information System (INIS)

    Huang, Y.; Berry, W.; Cooper, H.; Zachariah, Y.; Newman, T.

    1979-01-01

    Rabbits were employed as experimental models to evaluate a solid-phase radioimmunoassay (RIA) method for the diagnosis of systematic candidiasis. Ten rabbits were incubated subcutaneously to mimic superficial candidiasis and were found to produce no antibodies to Candida as determined by both immunodiffusion and RIA procedures. However, 94 per cent of 18 rabbits systematically infected by intravenous injection of Candida cells were observed to produce antibody as assessed by the RIA technique. These data encourage further tests with human sera and the continued development of this RIA procedure as a useful tool in the early serodiagnosis of systematic candidiasis. (Auth.)

  13. Detection of thrombocytic antibodies with the direct and indirect haemolysis inhibition test and the radioimmuno-Coombs test

    International Nuclear Information System (INIS)

    Mettenboerger, D.; Vith, E.

    1982-01-01

    Methods of application of the direct and indirect haemolysis inhibition test were studied in order to optimise the test parameters: The ultimate aim was to standardize the test method and compare its sensitivity in detecting various platelet antibodies with platelet indirect radioactive Coombs-test and the platelet immunofluorescence test. (orig.) [de

  14. [Evaluation of a rapid diagnostic test in the diagnosis of toxoplasmosis in pregnant women in Cotonou (Bénin)].

    Science.gov (United States)

    Ogouyèmi-Hounto, A; Agbayahoun-Chokki, F; Sissinto Savi de Tove, Y; Biokou Bankole, B; Adinsi de Souza, V; Assogba, M; Kinde-Gazard, D; Massougbodji, A

    2014-05-01

    The aim of the study was to evaluate the performance of the ImmunoComb® Toxo IgG and ImmunoComb® Toxo IgMassays (rapid diagnostic test) in the laboratory diagnosis of toxoplasmosis in pregnant women in Cotonou. We interviewed 266 pregnant women, who first answered an epidemiological questionnaire, and collected blood samples for measurement of IgG and IgM anti T. gondii antibodies with the ImmunoComb toxo assays and with the ARCHITECT CIMA method. The sensitivity, specificity, positive predictive values (PPV) and negative predictive values (NPV) were calculated to determine the performance of the rapid test. The seroprevalences of IgG against T. gondii by CIMA technique and rapid test were respectively 48.9% and 48.5%. The prevalence increased with age. Performances for IgG were: sensitivity 97%, specificity 100%, PPV 100%, NPV = 97.10%. For IgM, Sensitivity: 33.3% Specificity: 100%, PPV 100%, NPV = 99.2%. Seroprevalence obtained shows that about half of the study population is not immune against T. gondii and requires regular serological monitoring until delivery. According to these results, and given the needs of toxoplasmosis diagnosis on the field characterized by an important decrease of immunized women, this test may be recommended in the laboratory diagnosis of toxoplasmosis in peripheral levels of the health pyramid.

  15. Usefulness of Leukocyte Esterase Test Versus Rapid Strep Test for Diagnosis of Acute Strep Pharyngitis

    Directory of Open Access Journals (Sweden)

    Kumara V. Nibhanipudi MD

    2015-08-01

    Full Text Available Objective: A study to compare the usage of throat swab testing for leukocyte esterase on a test strip(urine dip stick-multi stick to rapid strep test for rapid diagnosis of Group A Beta hemolytic streptococci in cases of acute pharyngitis in children. Hypothesis: The testing of throat swab for leukocyte esterase on test strip currently used for urine testing may be used to detect throat infection and might be as useful as rapid strep. Methods: All patients who come with a complaint of sore throat and fever were examined clinically for erythema of pharynx, tonsils and also for any exudates. Informed consent was obtained from the parents and assent from the subjects. 3 swabs were taken from pharyngo-tonsillar region, testing for culture, rapid strep & Leukocyte Esterase. Results: Total number is 100. Cultures 9(+; for rapid strep== 84(- and16 (+; For LE== 80(- and 20(+ Statistics: From data configuration Rapid Strep versus LE test don’t seem to be a random (independent assignment but extremely aligned. The Statistical results show rapid and LE show very agreeable results. Calculated Value of Chi Squared Exceeds Tabulated under 1 Degree Of Freedom (P<.0.0001 reject Null Hypothesis and Conclude Alternative Conclusions: Leukocyte esterase on throat swab is as useful as rapid strep test for rapid diagnosis of strep pharyngitis on test strip currently used for urine dip stick causing acute pharyngitis in children.

  16. [An evaluation of the China-made HIV antibody test reagents].

    Science.gov (United States)

    Zheng, X W; Zhu, D

    1990-06-01

    This paper reports the results of the evaluation of the China-made HIV antibody screening test reagents, including the IF and IE reagents prepared by the Institute of Virology, CAPM, the ELISA reagent prepared by the Shanghai Institute of Biological Products. Based on the results, the sensitivities of the IF and IE are from 91.2% to 96.9%; the specificities, from 94.6% to 97.3%. Due to the low HIV prevalence in China, the predictive values of negative of these reagents are up to 100%; but the predictive values of positive are very low. It is suggested that these reagents can be used for HIV antibody screen testing in China. The package of some reagents should be improved, the price of some reagents should be decreased.

  17. Detection of LGI1 and CASPR2 antibodies with a commercial cell-based assay in patients with very high VGKC-complex antibody levels.

    Science.gov (United States)

    Yeo, T; Chen, Z; Chai, J Y H; Tan, K

    2017-07-15

    The presence of VGKC-complex antibodies, without LGI1/CASPR2 antibodies, as a standalone marker for neurological autoimmunity remains controversial. Additionally, the lack of an unequivocal VGKC-complex antibody cut-off level defining neurological autoimmunity makes it important to test for monospecific antibodies. We aim to determine the performance characteristics of a commercial assay (Euroimmun, Lübeck, Germany) for LGI1/CASPR2 antibody detection in patients with very high VGKC-complex antibody levels and report their clinico-serological associations. We identified 8 patients in our cohort with the highest VGKC-complex antibody levels (median 2663.5pM, range 933-6730pM) with VGKC-complex antibody related syndromes (Group A). Two other groups were identified; 1 group with suspected neuronal surface antibody syndromes and negative for VGKC-complex antibodies (Group B, n=8), and another group with cerebellar ataxia and negative for onconeuronal antibodies (Group C, n=8). Seven out of 8 patients (87.5%) in Group A had LGI1 and/or CASPR2 antibodies. One Group B patient had LGI1 antibodies but was negative on re-testing with a live cell assay. No Group C patients had monospecific antibodies. Inter-rater reliability was high; combining Groups A and B patients, the kappa statistic was 0.87 and 1.0 for LGI1 and CASPR2 antibodies respectively. We demonstrated that a high proportion of patients with very high VGKC-complex antibody levels and relevant clinical syndromes have LGI1 and/or CASPR2 antibodies detected by the commercial assay. Our findings lend support to the use of the assay for rapid and reliable detection of LGI1 and CASPR2 antibodies. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. A simple and rapid immunochromatographic test strip for detection of pathogenic isolates of Vibrio harveyi.

    Science.gov (United States)

    Sithigorngul, Paisarn; Rukpratanporn, Sombat; Pecharaburanin, Nilawan; Suksawat, Pornthip; Longyant, Siwaporn; Chaivisuthangkura, Parin; Sithigorngul, Weerawan

    2007-12-01

    Mouse monoclonal antibodies (MAbs) and rabbit polyclonal antibody (PAb) against Vibrio harveyi were generated from immunization of mice and rabbits with highly virulent isolate of V. harveyi. Two MAbs specific to virulent isolates of V. harveyi were obtained and one of them (VH4) was selected to conjugate with colloidal gold as the detector antibody was laid on a sample pad. Rabbit polyclonal antibody was used as the capture antibody at the test line (T) and goat anti-mouse IgG antibody (GAM) was used as the capture antibody at the control line (C) of nitrocellulose strip. The ready-to-use strip was held in a plastic case and then stored in a desiccated plastic bag. A sample volume of 100 microl of bacterial suspension from various sources mixed with application buffer was applied to the sample chamber at one end of the strip and allowed to flow by chromatography through the nitrocellulose membrane to the other end. In test samples containing virulent isolates of V. harveyi, the bacteria would bind to the monoclonal antibody conjugated with colloidal gold and the resulting complex would be captured by the antibodies at the test line to give a reddish-purple band. Any unbound monoclonal antibody conjugated with colloidal gold moved across the test line would be captured by the GAM and form a band at the control line (C). In sample without V. harveyi or with V. harveyi below the limit (culture. The beneficial features of this kit are that simple, convenient and quick results (within 15 min) can be obtained without the requirement of sophisticated tools or special equipments and skills.

  19. Evaluation of Calypte AWARE HIV-1/2 OMT antibody test as a screening test in an Indian setting

    Directory of Open Access Journals (Sweden)

    Ingole N

    2010-01-01

    Full Text Available Purpose: Integrated counselling and testing centres (ICTC provide counselling and blood testing facilities for HIV diagnosis. Oral fluid tests provide an alternative for people whodo not want blood to be drawn. Also, it avoids the risk of occupational exposure. The goal of this study was to evaluate the utility of Calypte AWARE HIV-1/2 OMT antibody test as a screening test in an Indian setting. Materials and Methods: A cross-sectional study was carried out after ethics committee approval in 250 adult ICTC clients. Blood was collected and tested from these clients for HIV diagnosis as per routine policy and the results were considered as the gold standard. Also, after another written informed consent, oral fluid was collected from the clients and tested for the presence of HIV antibodies. Twenty five clients who had and 25 clients who had not completed their secondary school education (Group A and Group B, respectively were also asked to perform and interpret the test on their own and their findings and experiences were noted. Result: The sensitivity, specificity, PPV and NPV of the oral fluid antibody test were 100%, 98.51%, 94.11% and 100%, respectively. Seventy six percent of clients preferred oral fluid testing. Group B found it difficult to perform the test as compared to Group A and this difference was statistically significant (P ≤ 0.05. Conclusion: Oral fluid testing can be used as a screening test for HIV diagnosis; however, confirmation of reactive results by blood-based tests is a must.

  20. Comparison of rapid diagnostic tests to detect Mycobacterium avium subsp. paratuberculosis disseminated infection in bovine liver.

    Science.gov (United States)

    Zarei, Mehdi; Ghorbanpour, Masoud; Tajbakhsh, Samaneh; Mosavari, Nader

    2017-08-01

    Mycobacterium avium subsp. paratuberculosis (MAP) causes Johne's disease, a chronic enteritis in cattle and other domestic and wild ruminants. The presence of MAP in tissues other than intestines and associated lymph nodes, such as meat and liver, is a potential public health concern. In the present study, the relationship between the results of rapid diagnostic tests of the Johne's disease, such as serum ELISA, rectal scraping PCR, and acid-fast staining, and the presence of MAP in liver was evaluated. Blood, liver, and rectal scraping samples were collected from 200 slaughtered cattle with unknown Johne's disease status. ELISA was performed to determine the MAP antibody activity in the serum. Acid-fast staining was performed on rectal scraping samples, and PCR was performed on rectal scraping and liver samples. PCR-positive liver samples were used for mycobacterial culture. Overall, the results of this study demonstrated that MAP can be detected and cultured from liver of slaughtered cattle and rapid diagnostic tests of Johne's disease have limited value in detecting cattle with MAP infection in liver. These findings show that the presence of MAP in liver tissue may occur in cows with negative results for rapid diagnostic tests and vice versa. Hence, liver might represent another possible risk of human exposure to MAP. Given concerns about a potential zoonotic role for MAP, these results show the necessity to find new methods for detecting cattle with MAP disseminated infection.

  1. Monoclonal antibody technologies and rapid detection assays

    Science.gov (United States)

    Novel methodologies and screening strategies will be outlined on the use of hybridoma technology for the selection of antigen specific monoclonal antibodies. The development of immunoassays used for diagnostic detection of prions and bacterial toxins will be discussed and examples provided demonstr...

  2. Antigen spot test (AST): a highly sensitive assay for the detection of antibodies

    Energy Technology Data Exchange (ETDEWEB)

    Herbrink, P; van Bussel, F J; Warnaar, S O [Rijksuniversiteit Leiden (Netherlands)

    1982-02-12

    A method is described for detection of antibodies by means of nitrocellulose or diazobenzyloxymethyl (DBM) paper on which various antigens have been spotted. The sensitivity of this antigen spot test (AST) is comparable with that of RIA and ELISA. The method requires only nanogram amounts of antigen. Since a variety of antigens can be spotted on a single piece of nitrocellulose or DBM paper, this antigen spot test is especially useful for specificity controls on antibodies.

  3. Colloidal gold probe based rapid immunochromatographic strip assay for cortisol

    International Nuclear Information System (INIS)

    Nara, Seema; Tripathi, Vinay; Singh, Harpal; Shrivastav, Tulsidas G.

    2010-01-01

    A rapid and semi-quantitative immunochromatographic strip (ICS) test for cortisol analysis in serum was developed. The test strip was based on a competitive assay format. Colloidal gold nanoparticles were synthesized and coupled with cortisol-3-carboxymethyloxime-adipic acid dihydrazide-bovine serum albumin (F-3-CMO-ADH-BSA) antigen to directly compete with cortisol in human serum samples. F-3-CMO-ADH-BSA-gold label and uncoupled colloidal gold nanoparticles were appropriately characterized using UV-vis spectroscopy, transmission electron microscopy and atomic force microscopy. Anticortisol antibody raised against F-3-CMO-BSA immunogen in New Zealand white rabbits was coated on the NC membrane as test line. Anti-BSA antibody was used as control line. The lower detection limit of the ICS test was 30 ng mL -1 with visual detection and was completed in 10 min. About 30 human serum samples were also analyzed by the developed strip test and their range of cortisol concentration was established. The developed ICS test is rapid, economic and user friendly.

  4. Colloidal gold probe based rapid immunochromatographic strip assay for cortisol

    Energy Technology Data Exchange (ETDEWEB)

    Nara, Seema, E-mail: seemanara@mnnit.ac.in [Department of Applied Mechanics (Biotechnology), Motilal Nehru National Institute of Technology, Allahabad 211004 (India); Department of Reproductive Biomedicine, National Institute of Health and Family Welfare, Munirka, New Delhi 110067 (India); Center for BioMedical Engineering, Indian Institute of Technology, New Delhi 110016 (India); Tripathi, Vinay [Department of Reproductive Biomedicine, National Institute of Health and Family Welfare, Munirka, New Delhi 110067 (India); Center for BioMedical Engineering, Indian Institute of Technology, New Delhi 110016 (India); Singh, Harpal [Center for BioMedical Engineering, Indian Institute of Technology, New Delhi 110016 (India); Shrivastav, Tulsidas G. [Department of Reproductive Biomedicine, National Institute of Health and Family Welfare, Munirka, New Delhi 110067 (India)

    2010-12-03

    A rapid and semi-quantitative immunochromatographic strip (ICS) test for cortisol analysis in serum was developed. The test strip was based on a competitive assay format. Colloidal gold nanoparticles were synthesized and coupled with cortisol-3-carboxymethyloxime-adipic acid dihydrazide-bovine serum albumin (F-3-CMO-ADH-BSA) antigen to directly compete with cortisol in human serum samples. F-3-CMO-ADH-BSA-gold label and uncoupled colloidal gold nanoparticles were appropriately characterized using UV-vis spectroscopy, transmission electron microscopy and atomic force microscopy. Anticortisol antibody raised against F-3-CMO-BSA immunogen in New Zealand white rabbits was coated on the NC membrane as test line. Anti-BSA antibody was used as control line. The lower detection limit of the ICS test was 30 ng mL{sup -1} with visual detection and was completed in 10 min. About 30 human serum samples were also analyzed by the developed strip test and their range of cortisol concentration was established. The developed ICS test is rapid, economic and user friendly.

  5. Atypical presentation of probable Creutzfeldt-Jakob disease associated with anti-Zic4 antibody: Literature review of neuronal antibodies in Creutzfeldt-Jakob disease.

    Science.gov (United States)

    Salazar, Richard

    2018-05-01

    Sporadic Creutzfeldt-Jakob disease is a prion disease characterized by rapidly progressive dementia, ataxia and myoclonus. Atypical phenotype masquerading as stroke, movement disorders or autoimmune encephalitis have been described. Here, I report a probable case of sCJD with an atypical presentation associated with anti-Zic4 antibody and review the literature of neuronal antibodies in CJD. A 70 year-old gentleman is admitted with a 2-month history of recurrent stroke-like symptoms associated with behavioral disturbances, gait ataxia and rapidly progressive dementia. His initial examination demonstrated akinetic mutism, diffuse rigidity, dysautononia, and Cheyne-Stokes respiration. Over the following weeks his condition progressed to profound coma. A comprehensive infectious, metabolic, inflammatory and autoimmune work-up yielded negative results. Empiric immunosuppressive therapy ensued. He expired three months after symptoms onset. Autopsy was not performed. After his demise, prion tests came back abnormal for elevated 14-3-3 protein, total tau and positive RTQuIC. Later on, anti-Zic4 antibodies were found in serum. This case underscores the importance of a high index of suspicion for CJD even in case of atypical features or the concurrence of neuronal antibodies. Further larger prospective studies on the prevalence of these neuronal antibodies in CJD and the contribution of these autoantibodies to disease pathophysiology are necessary. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Antibodies from plants for bionanomaterials

    OpenAIRE

    Edgue, G.; Twyman, R.M.; Beiss, V.; Fischer, R.; Sack, M.

    2017-01-01

    Antibodies are produced as part of the vertebrate adaptive immune response and are not naturally made by plants. However, antibody DNA sequences can be introduced into plants, and together with laboratory technologies that allow the design of antibodies recognizing any conceivable molecular structure, plants can be used as green factories' to produce any antibody at all. The advent of plant-based transient expression systems in particular allows the rapid, convenient, and safe production of a...

  7. Rapid pile load tests in the geotechnical centrifuge

    NARCIS (Netherlands)

    Holscher, P.; Van Tol, A.F.; Huy, N.Q.

    2012-01-01

    Centrifiige experiments were carried out to gain insight into the factors that affect the mobilized resistance during rapid load testing on piles in sand. The influence of generated pore water pressure during rapid load tests is shidied, and its effect on the commonly used unloadmg point method to

  8. Mumps prophylaxis in the light of a new test for antibody.

    Science.gov (United States)

    Mortimer, P P

    1978-01-01

    A radial haemolysis test was used to investigate immunity to mumps. Antibody was found in 92 (42%) out of 220 children aged up to 5 years, 124 (78%) out of 159 children aged 6--10 years, 192 (86%) out of 222 children aged 11 years, 138 (92%) out of 150 children aged 15 years, and 280 (95%) out of 296 women attending an antenatal clinic. A group of 307 cadets aged 16--18 years were also tested and interviewed: 133 (95%) out of 140 who said that they had had mumps and 108 (87%) out of 124 who said that they had not had mumps were found to have antibody. The results suggest that tests for immunity to mumps by radial haemolysis would permit more rational use of mumps-specific immunoglobulin and attenuated mumps vaccine. PMID:365288

  9. [Comparison of eight screening tests for ant-HCV antibody].

    Science.gov (United States)

    Deguchi, Matsuo; Kagita, Masanori; Yamashita, Naoko; Nakano, Takasi; Tahara, Kazuko; Asari, Seishi; Iwatani, Yoshinori

    2002-09-01

    We compared eight HCV screening tests for detection of anti-HCV antibody; Ortho Quick Chaser HCV Ab (QC), Ortho HCV Ab ELISA III (ELISA), Ortho HVC Ab PA test III (PA), Lumipulse II Ortho HCV (LUMI), IMx HCV.DAINAPACKII (IMx), ARCHITECT HCV (ARCH), Immucheck.F-HCV C50 Ab (Immu), RANREAM HCV Ab Ex II (RAN). Sera from six hundred patients were examined by these eight screening tests. The positive rates of the eight screening tests were from 9.0% to 13.2%. Forty-five sera showed discrepant results between the eight screening tests, and about half of them showed weak positive reaction and/or false positive. Twenty-five of the forty-five sera were negative for ant-HCV antibody in the CHIRON RIBA III confirmatory test, and forty-four of them were negative for HCV-RNA in the PCR method. The agreement rates between the two reagents were from 95.5% to 99.2%, but were not always high between the two reagents that used similar antigen. The specificities and sensitivities evaluated by using the RIBA III confirmatory test were excellent in ELISA, LUMI, IMx, ARCH and Immu. Three BBI seroconversion panels were used to compare the positive readings in the initial stage of HCV infection by eight screening tests. ELISA and ARCH showed the earliest positive readings, and then IMx, LUMI = RAN, PA, QC and Immu in this order. These findings indicate that ELISA and ARCH were the most excellent in the sensitivity, specificity and early diagnosis of HCV infection. However, we must pay attention to the weak positive reaction in the screening tests, because there is a possibility of "false positive".

  10. Therapeutic Recombinant Monoclonal Antibodies

    Science.gov (United States)

    Bakhtiar, Ray

    2012-01-01

    During the last two decades, the rapid growth of biotechnology-derived techniques has led to a myriad of therapeutic recombinant monoclonal antibodies with significant clinical benefits. Recombinant monoclonal antibodies can be obtained from a number of natural sources such as animal cell cultures using recombinant DNA engineering. In contrast to…

  11. A liquid phase blocking ELISA for the detection of antibodies against infectious bronchitis virus

    Directory of Open Access Journals (Sweden)

    Cardoso T.C.

    1999-01-01

    Full Text Available A liquid phase blocking ELISA (LPB-ELISA was developed for the detection and measurement of antibodies against infectious bronchitis virus (IBV. The purified and nonpurified virus used as antigen, the capture and detector antibodies, and the chicken hyperimmune sera were prepared and standardized for this purpose. A total of 156 sera from vaccinated and 100 from specific pathogen-free chickens with no recorded contact with the virus were tested. The respective serum titers obtained in the serum neutralization test (SNT were compared with those obtained in the LPB-ELISA. There was a high correlation (r2 = 0.8926 between the two tests. The LPB-ELISA represents a single test suitable for the rapid detection of antibodies against bronchitis virus in chicken sera, with good sensitivity (88%, specificity (100% and agreement (95.31%.

  12. Identification of anti-HPA-1a allo-antibodies using IgG platelet antibody detection and crossmatch system assay with Galileo Echo.

    Science.gov (United States)

    Di Cristofaro, Julie; Frassati, Coralie; Montagnie, Rolande; Basire, Agnes; Merieux, Yves; Picard, Christophe

    2015-01-01

    Fetal/neonatal allo-immune thrombocytopenia is the most frequent and the most dangerous clinical condition involving anti-human platelet antigens (HPA)-1a allo-antibodies. Anti-HPA-1a allo-immunization requires rapid and accurate diagnosis to determine appropriate treatment. The Capture-P Ready-Screen assay (C-PRS) is a new qualitative immunoassay to detect IgG anti-human leukocyte antigen (HLA) and anti-HPA allo-antibodies. The aim of this study is to assess the identification of anti-HPA-1a allo-antibodies using the C-PRS assay, associated with HLA class I stripping reagents, on the automated benchtop analyzer Galileo Echo. Forty-nine sera were analyzed: without anti-HLA class I or anti-HPA allo-antibodies, with anti-HLA class I allo-antibodies, with anti-HPA-1a allo-antibodies, among which with anti-HLA class I allo-antibodies. None of the samples without allo-antibodies were reactive. Only anti-HLA antibodies, detected by cytotoxicity-dependent complement and not by Luminex, remained positive before and after stripping reagents. Of the 13 samples, anti-HPA-1a allo-antibodies that were correctly identified before and after incubation with HLA assassin reagent were 70% and 85%, respectively. Anti-glycoprotein auto-antibodies and anti-HLA allo-antibodies do not interfere with the detection of anti-HPA-1a antibodies. This preliminary study indicates that further improvement of the test will be helpful in developing a clinically useful assay in the future.

  13. Oral rapid test: an alternative to traditional HIV screening in Chile

    Directory of Open Access Journals (Sweden)

    Lisette Paola Irarrazábal

    2013-06-01

    Full Text Available OBJECTIVE: To compare the sensitivity and specificity of an Oral Rapid Test (ORT to that of the Enzyme-Linked Immunosorbent Assay (ELISA for HIV testing in Santiago, Chile; to track the number of study participants returning for ELISA testing results; and to analyze the participants' perceptions of the ORT compared to the ELISA. METHODS: A total of 497 people were recruited in Santiago, Chile: 153 had previously tested positive for HIV, and 344 were of unknown status. Participants were tested for HIV using both the ELISA and the ORT to examine and compare specificity and sensitivity. Qualitative data were collected from 22 participants to compare perceptions of the testing experience with ORT versus ELISA. RESULTS: The ELISA reported 184 (37% of the 497 participants as being "positive" for HIV antibodies; the ORT showed 181 (36.4% as being "reactive" for HIV. The ORT showed a sensitivity of 98.4% (95.7%-99.9%, 95% Confidence Interval and specificity of 100%. The Kappa test produced K = 0.983 (P < 0.0001. Of the 344 participants whose HIV status was unknown at the start of the study, 55 failed to return for their ELISA results. Participants positively perceived ORT as having reduced both waiting time and anxiety over obtaining their test results. ORT oral swabbing appeared more practical and less invasive than drawing blood for the ELISA. CONCLUSIONS: The ORT and ELISA were statistically equal in specificity and sensitivity. ORT provides quicker results, potentially ensuring that more people receive them, and does not require handling of or exposure to potentially hazardous blood products. Trial number: ClinicalTrials.gov identifier: NCT01733927.

  14. Screening test for neutralizing antibodies against yellow fever virus, based on a flavivirus pseudotype.

    Directory of Open Access Journals (Sweden)

    Séverine Mercier-Delarue

    Full Text Available Given the possibility of yellow fever virus reintroduction in epidemiologically receptive geographic areas, the risk of vaccine supply disruption is a serious issue. New strategies to reduce the doses of injected vaccines should be evaluated very carefully in terms of immunogenicity. The plaque reduction test for the determination of neutralizing antibodies (PRNT is particularly time-consuming and requires the use of a confinement laboratory. We have developed a new test based on the use of a non-infectious pseudovirus (WN/YF17D. The presence of a reporter gene allows sensitive determination of neutralizing antibodies by flow cytometry. This WN/YF17D test was as sensitive as PRNT for the follow-up of yellow fever vaccinees. Both tests lacked specificity with sera from patients hospitalized for acute Dengue virus infection. Conversely, both assays were strictly negative in adults never exposed to flavivirus infection or vaccination, and in patients sampled some time after acute Dengue infection. This WN/YF17D test will be particularly useful for large epidemiological studies and for screening for neutralizing antibodies against yellow fever virus.

  15. Antibody informatics for drug discovery

    DEFF Research Database (Denmark)

    Shirai, Hiroki; Prades, Catherine; Vita, Randi

    2014-01-01

    to the antibody science in every project in antibody drug discovery. Recent experimental technologies allow for the rapid generation of large-scale data on antibody sequences, affinity, potency, structures, and biological functions; this should accelerate drug discovery research. Therefore, a robust bioinformatic...... infrastructure for these large data sets has become necessary. In this article, we first identify and discuss the typical obstacles faced during the antibody drug discovery process. We then summarize the current status of three sub-fields of antibody informatics as follows: (i) recent progress in technologies...... for antibody rational design using computational approaches to affinity and stability improvement, as well as ab-initio and homology-based antibody modeling; (ii) resources for antibody sequences, structures, and immune epitopes and open drug discovery resources for development of antibody drugs; and (iii...

  16. The microdose rapid 14C urea breath test compares well with the original rapid 14 breath test

    International Nuclear Information System (INIS)

    Bellon, M.S.; Bartholomeusz, F.D.L.; Chatterton, B.E.

    2000-01-01

    Full text: The 14 C urea breath test (CUBT) is a sensitive test used in the detection of H. pylori infection. The rapid 14 CUBT using 185 KBq of 14 C urea showed a sensitivity of 100% when tested in 36 patients. The aim of this study was to compare the results of the 14 CUBT performed following the ingestion of 37KBq microdose 14 C urea capsule (Bicapsule, Trimed) with the earlier method which uses 185 KBq 14 C urea. 19 patients (nine female age 21-52 yrs) were studied. All subjects first underwent a 14 CUBT with the microdose capsule and a single 15 minute post ingestion sample. An hour later the test was repeated but with a dose of 185 KBq 14 C urea in liquid form. A normal result was taken as 2 = 0.92). This is shown above. The Rapid 14 CUBT performed following the microdose capsule whilst reducing patient radiation exposure is an accurate test for the detection of H. pylori. Copyright (2000) The Australian and New Zealand Society of Nuclear Medicine Inc

  17. Synthesis of indium-labeled antibody-chelate conjugates for radioassays

    Energy Technology Data Exchange (ETDEWEB)

    Gokce, A; Nakamura, R M; Tubis, M; Wolf, W

    1982-01-01

    A method has been developed to achieve rapid and reproducible complexation of indium to transferrin at pH 7.4. The system consists of nitrilotriacetic acid (NTA) as the intermediate carrier ligand, whose function is to allow the /sup 113/m In ion, in a solution in Tris buffer, pH 7.4, to be transferred rapidly to the specific binding sites on transferrin. Just as in the case of iron, this complexation requires the presence of a synergistic ion such as bicarbonate. The present system can be used to allow the binding of /sup 113/mIn to transferrin when coupled to an antibody. This method has been tested by studying the conjugation of an antibody, the IgG fraction of goat anti-rabbit-IgG, with either transferrin or desferoxamine, using glutaraldehyde as the coupling agent. Optimization in terms of total protein concentration and glutaraldehyde levels lead to products where the specific metal binding capacity of the transferrin moiety remains unchanged, and where the antibody retains 70% of its antigenic activity. The present system can be considered an extension of the ELISA techniques and can be used to determine, by a terminal /sup 113/mIn labeling technique, the level of specific binding of an antibody to its antigen.

  18. Comparison of the efficiency of antibody selection from semi-synthetic scFv and non-immune Fab phage display libraries against protein targets for rapid development of diagnostic immunoassays.

    Science.gov (United States)

    Chan, Conrad E Z; Chan, Annie H Y; Lim, Angeline P C; Hanson, Brendon J

    2011-10-28

    Rapid development of diagnostic immunoassays against novel emerging or genetically modified pathogens in an emergency situation is dependent on the timely isolation of specific antibodies. Non-immune antibody phage display libraries are an efficient in vitro method for selecting monoclonal antibodies and hence ideal in these circumstances. Such libraries can be constructed from a variety of sources e.g. B cell cDNA or synthetically generated, and use a variety of antibody formats, typically scFv or Fab. However, antibody source and format can impact on the quality of antibodies generated and hence the effectiveness of this methodology for the timely production of antibodies. We have carried out a comparative screening of two antibody libraries, a semi-synthetic scFv library and a human-derived Fab library against the protective antigen toxin component of Bacillus anthracis and the epsilon toxin of Clostridium botulinum. We have shown that while the synthetic library produced a diverse collection of specific scFv-phage, these contained a high frequency of unnatural amber stops and glycosylation sites which limited their conversion to IgG, and also a high number which lost specificity when expressed as IgG. In contrast, these limitations were overcome by the use of a natural human library. Antibodies from both libraries could be used to develop sandwich ELISA assays with similar sensitivity. However, the ease and speed with which full-length IgG could be generated from the human-derived Fab library makes screening this type of library the preferable method for rapid antibody generation for diagnostic assay development. Copyright © 2011 Elsevier B.V. All rights reserved.

  19. Accuracy and user-acceptability of HIV self-testing using an oral fluid-based HIV rapid test.

    Directory of Open Access Journals (Sweden)

    Oon Tek Ng

    Full Text Available BACKGROUND: The United States FDA approved an over-the-counter HIV self-test, to facilitate increased HIV testing and earlier linkage to care. We assessed the accuracy of self-testing by untrained participants compared to healthcare worker (HCW testing, participants' ability to interpret sample results and user-acceptability of self-tests in Singapore. METHODOLOGY/PRINCIPAL FINDINGS: A cross-sectional study, involving 200 known HIV-positive patients and 794 unknown HIV status at-risk participants was conducted. Participants (all without prior self-test experience performed self-testing guided solely by visual instructions, followed by HCW testing, both using the OraQuick ADVANCE Rapid HIV 1/2 Antibody Test, with both results interpreted by the HCW. To assess ability to interpret results, participants were provided 3 sample results (positive, negative, and invalid to interpret. Of 192 participants who tested positive on HCW testing, self-testing was positive in 186 (96.9%, negative in 5 (2.6%, and invalid in 1 (0.5%. Of 794 participants who tested negative on HCW testing, self-testing was negative in 791 (99.6%, positive in 1 (0.1%, and invalid in 2 (0.3%. Excluding invalid tests, self-testing had sensitivity of 97.4% (95% CI 95.1% to 99.7% and specificity of 99.9% (95% CI: 99.6% to 100%. When interpreting results, 96%, 93.1% and 95.2% correctly read the positive, negative and invalid respectively. There were no significant demographic predictors for false negative self-testing or wrongly interpreting positive or invalid sample results as negative. Eighty-seven percent would purchase the kit over-the-counter; 89% preferred to take HIV tests in private. 72.5% and 74.9% felt the need for pre- and post-test counseling respectively. Only 28% would pay at least USD15 for the test. CONCLUSIONS/SIGNIFICANCE: Self-testing was associated with high specificity, and a small but significant number of false negatives. Incorrectly identifying model results as

  20. A commercial ELISA detects high levels of human H5 antibody but cross-reacts with influenza A antibodies.

    Science.gov (United States)

    Stelzer-Braid, Sacha; Wong, Bruce; Robertson, Peter; Lynch, Garry W; Laurie, Karen; Shaw, Robert; Barr, Ian; Selleck, Paul W; Baleriola, Cristina; Escott, Ros; Katsoulotos, Gregory; Rawlinson, William D

    2008-10-01

    Commercial serological assays to determine influenza A H5N1 infection are available, although the accuracy and reproducibility of these are not reported in detail. This study aimed to assess the validity of a commercial ELISA H5 hemagglutinin (HA) antibody kit. A commercial ELISA for detection of antibodies towards influenza A H5 HA was evaluated using human sera from vaccinated individuals. The ELISA was used to screen 304 sera with elevated influenza A complement fixation titres collected between the period 1995-2007. The ELISA was found to be accurate for sera with high levels of anti-H5 antibodies, and would be useful in clinical settings where a rapid result is required. Thirteen of the stored sera were positive using the ELISA, but were confirmed as negative for H5N1 exposure using further serological tests. Absorption studies suggested that antibodies towards seasonal H3N2 and H1N1 influenza may cross-react with H5 antigen, giving false positive results with the ELISA.

  1. Rapid Quantification of the Toxic Alga Prymnesium parvum in Natural Samples by Use of a Specific Monoclonal Antibody and Solid-Phase Cytometry

    DEFF Research Database (Denmark)

    West, N. J.; Bacchieri, R.; Hansen, Gert

    2006-01-01

    The increasing incidence of harmful algal blooms around the world and their associated health and economic effects require the development of methods to rapidly and accurately detect and enumerate the target species. Here we describe use of a solid-phase cytometer to detect and enumerate the toxi......-phase cytometer can be used to rapidly enumerate natural P. parvum cells and that it could be used to detect other toxic algae, with an appropriate antibody or DNA probe....

  2. Cell-free synthesis of functional antibody fragments to provide a structural basis for antibody-antigen interaction.

    Directory of Open Access Journals (Sweden)

    Takayoshi Matsuda

    Full Text Available Growing numbers of therapeutic antibodies offer excellent treatment strategies for many diseases. Elucidation of the interaction between a potential therapeutic antibody and its target protein by structural analysis reveals the mechanism of action and offers useful information for developing rational antibody designs for improved affinity. Here, we developed a rapid, high-yield cell-free system using dialysis mode to synthesize antibody fragments for the structural analysis of antibody-antigen complexes. Optimal synthesis conditions of fragments (Fv and Fab of the anti-EGFR antibody 059-152 were rapidly determined in a day by using a 30-μl-scale unit. The concentration of supplemented disulfide isomerase, DsbC, was critical to obtaining soluble antibody fragments. The optimal conditions were directly applicable to a 9-ml-scale reaction, with linear scalable yields of more than 1 mg/ml. Analyses of purified 059-152-Fv and Fab showed that the cell-free synthesized antibody fragments were disulfide-bridged, with antigen binding activity comparable to that of clinical antibodies. Examination of the crystal structure of cell-free synthesized 059-152-Fv in complex with the extracellular domain of human EGFR revealed that the epitope of 059-152-Fv broadly covers the EGF binding surface on domain III, including residues that formed critical hydrogen bonds with EGF (Asp355EGFR, Gln384EGFR, H409EGFR, and Lys465EGFR, so that the antibody inhibited EGFR activation. We further demonstrated the application of the cell-free system to site-specific integration of non-natural amino acids for antibody engineering, which would expand the availability of therapeutic antibodies based on structural information and rational design. This cell-free system could be an ideal antibody-fragment production platform for functional and structural analysis of potential therapeutic antibodies and for engineered antibody development.

  3. Inadequacy of IgM antibody tests for diagnosis of Rocky Mountain Spotted Fever.

    Science.gov (United States)

    McQuiston, Jennifer H; Wiedeman, Caleb; Singleton, Joseph; Carpenter, L Rand; McElroy, Kristina; Mosites, Emily; Chung, Ida; Kato, Cecilia; Morris, Kevin; Moncayo, Abelardo C; Porter, Susan; Dunn, John

    2014-10-01

    Among 13 suspected Rocky Mountain spotted fever (RMSF) cases identified through an enhanced surveillance program in Tennessee, antibodies to Rickettsia rickettsii were detected in 10 (77%) patients using a standard indirect immunofluorescent antibody (IFA) assay. Immunoglobulin M (IgM) antibodies were observed for 6 of 13 patients (46%) without a corresponding development of IgG, and for 3 of 10 patients (30%) at least 1 year post-onset. However, recent infection with a spotted fever group rickettsiae could not be confirmed for any patient, based on a lack of rising antibody titers in properly timed acute and convalescent serologic specimens, and negative findings by polymerase chain reaction testing. Case definitions used in national surveillance programs lack specificity and may capture cases that do not represent current rickettsial infections. Use of IgM antibodies should be reconsidered as a basis for diagnosis and public health reporting of RMSF and other spotted fever group rickettsiae in the United States. © The American Society of Tropical Medicine and Hygiene.

  4. Neutralization of antibody-enhanced dengue infection by VIS513, a pan serotype reactive monoclonal antibody targeting domain III of the dengue E protein

    Science.gov (United States)

    Robinson, Luke N.; Ong, Li Ching; Rowley, Kirk J.; Winnett, Alexander; Tan, Hwee Cheng; Hobbie, Sven; Shriver, Zachary; Babcock, Gregory J.; Alonso, Sylvie; Ooi, Eng Eong

    2018-01-01

    Dengue virus (DENV) infection imposes enormous health and economic burden worldwide with no approved treatment. Several small molecules, including lovastatin, celgosivir, balapiravir and chloroquine have been tested for potential anti-dengue activity in clinical trials; none of these have demonstrated a protective effect. Recently, based on identification and characterization of cross-serotype neutralizing antibodies, there is increasing attention on the potential for dengue immunotherapy. Here, we tested the ability of VIS513, an engineered cross-neutralizing humanized antibody targeting the DENV E protein domain III, to overcome antibody-enhanced infection and high but brief viremia, which are commonly encountered in dengue patients, in various in vitro and in vivo models. We observed that VIS513 efficiently neutralizes DENV at clinically relevant viral loads or in the presence of enhancing levels of DENV immune sera. Single therapeutic administration of VIS513 in mouse models of primary infection or lethal secondary antibody-enhanced infection, reduces DENV titers and protects from lethal infection. Finally, VIS513 administration does not readily lead to resistance, either in cell culture systems or in animal models of dengue infection. The findings suggest that rapid viral reduction during acute DENV infection with a monoclonal antibody is feasible. PMID:29425203

  5. The meningococcal antibody test: how useful in the diagnosis of meningococcal disease?

    DEFF Research Database (Denmark)

    Weis, N; Berthelsen, L; Wachmann, H

    2005-01-01

    Based on 9257 [correction] blood samples received from 7365 patients with a request for a meningococcal antibody test (MAT) during a 10-year period (1986-1995), the usefulness of the test in the diagnosis of meningococcal disease was assessed. Of 635 patients with culture-confirmed meningococcal ...

  6. rapid assessment of polio virus antibodies prevalence amongst

    African Journals Online (AJOL)

    ISSN 1597-6343. Polio Virus Antibodies Prevalence Amongst Children In Kano State ... poliovirus serotypes (types 1, 2 or 3) which cause poliomyelitis. They are spread by ..... all those that have contributed to the overall success of this work.

  7. Commercial serological antibody detection tests for the diagnosis of pulmonary tuberculosis: a systematic review.

    Directory of Open Access Journals (Sweden)

    Karen R Steingart

    2007-06-01

    Full Text Available BACKGROUND: The global tuberculosis epidemic results in nearly 2 million deaths and 9 million new cases of the disease a year. The vast majority of tuberculosis patients live in developing countries, where the diagnosis of tuberculosis relies on the identification of acid-fast bacilli on unprocessed sputum smears using conventional light microscopy. Microscopy has high specificity in tuberculosis-endemic countries, but modest sensitivity which varies among laboratories (range 20% to 80%. Moreover, the sensitivity is poor for paucibacillary disease (e.g., pediatric and HIV-associated tuberculosis. Thus, the development of rapid and accurate new diagnostic tools is imperative. Immune-based tests are potentially suitable for use in low-income countries as some test formats can be performed at the point of care without laboratory equipment. Currently, dozens of distinct commercial antibody detection tests are sold in developing countries. The question is "do they work?" METHODS AND FINDINGS: We conducted a systematic review to assess the accuracy of commercial antibody detection tests for the diagnosis of pulmonary tuberculosis. Studies from all countries using culture and/or microscopy smear for confirmation of pulmonary tuberculosis were eligible. Studies with fewer than 50 participants (25 patients and 25 control participants were excluded. In a comprehensive search, we identified 68 studies. The results demonstrate that (1 overall, commercial tests vary widely in performance; (2 sensitivity is higher in smear-positive than smear-negative samples; (3 in studies of smear-positive patients, Anda-TB IgG by enzyme-linked immunosorbent assay shows limited sensitivity (range 63% to 85% and inconsistent specificity (range 73% to 100%; (4 specificity is higher in healthy volunteers than in patients in whom tuberculosis disease is initially suspected and subsequently ruled out; and (5 there are insufficient data to determine the accuracy of most

  8. A comparison of rapid diagnostic testing (by plasmodium lactate ...

    African Journals Online (AJOL)

    Background: The World Health Organization (WHO) considers early and rapid diagnosis as one of the strategies to control malaria. This study compared the performance of Quantitative Buffy Coat (QBC) test and the Plasmodium lactate dehydrogenase (pLDH) rapid diagnostic test (RDT) with microscopy as the gold ...

  9. HIV Antibody Testing among Adults in the United States: Data from 1988 NHIS.

    Science.gov (United States)

    Hardy, Ann M.; Dawson, Deborah A.

    1990-01-01

    Analyzes statistical data from 1988 National Health Interview Survey to determine adult awareness of and experience with HIV antibody testing. Following findings reported: most knew of test; 17 percent had been tested; Blacks and Hispanics were more likely than Whites to have been voluntarily tested; and high-risk group members were more likely…

  10. Evaluation of a Community's Risk for Canine Parvovirus and Distemper Using Antibody Testing and GIS Mapping of Animal Shelter Intakes.

    Science.gov (United States)

    Spindel, Miranda E; Krecic, Matthew R; Slater, Margaret R; Vigil, Nicole

    2018-03-20

    This cross-sectional study aimed to identify where dogs with negative antibody tests to canine parvovirus (CPV) and canine distemper virus (CDV) originated when entering a community shelter, using a commercially available ELISA antibody test and Geographic Information Systems mapping. Of 2745 canines entering during a three-month period, 1056 test results were obtained. Dogs or puppies weighing over 2 lb were eligible if they could be humanely, nonchemically restrained for phlebotomy. Age and minor health issues weren't exclusions. Dogs were excluded if trained personnel were concerned health would be compromised by phlebotomy. Blood samples were collected within 24 hours of entry. Four hundred and twenty-seven (40%) dogs had positive antibody test results for both viruses, 422 (40%) were positive for CPV, 37 (4%) were positive for CDV, and 170 (16%) were negative for both. Mapping revealed geographic patterns for dogs with negative antibody tests. This shelter admitted dogs with negative CPV and/or CDV antibody tests from defined community areas. Targeting vaccination efforts in communities to areas where dogs with negative antibody tests originate could be an effective wellness strategy.

  11. A simple kit for rapid field diagnosis of potato virus Y by latex serological test

    Directory of Open Access Journals (Sweden)

    Aarne Kurppa

    1987-07-01

    Full Text Available A simple kit for rapid detection of potato virus Y by latex serological test was developed. The test is carried out on a white cardboard sheet and the results can be read by naked eye in two minutes. A test card of 10 x 6 cm holds latex sensitized antibodies, buffers and other necessary ingredients as dry blue colored formulate on the ringed areas of the card. A test card includes space for six tests and positive and negative controls. The kit also includes disposable plastic sticks for mixing the samples with test reagents and a hand press with disposable plastic tips. For testing, dried reagents are dissolved in drops of sample and mixed. After gentle rotation, samples containing virus appear clearly granulated while samples from healthy plants remain unagglutinated. The testing of undiluted extracts of evenly developed tuber sprouts resulted in over 91 % identity with the results obtained with ELISA that was used as a control method. Testing of diluted leaf extracts reached the same reliability but undiluted leaf extracts from glasshouse grown potatoes were not well suitable as test samples because of their dark green color. No such problems occurred with field grown material and a complete identity with the ELISA readings was true when the samples included secondarily infected potato plants. No reaction to other potato viruses than PVY was obtained by the test kit.

  12. Effects of blood contamination of cerebrospinal fluid on results of indirect fluorescent antibody tests for detection of antibodies against Sarcocystis neurona and Neospora hughesi.

    Science.gov (United States)

    Finno, Carrie J; Packham, Andrea E; David Wilson, W; Gardner, Ian A; Conrad, Patricia A; Pusterla, Nicola

    2007-05-01

    The purpose of this study was to determine the effect of blood contamination of cerebrospinal fluid (CSF) on the results of indirect fluorescent antibody tests (IFATs) for Sarcocystis neurona and Neospora hughesi. The in vitro study used antibody-negative CSF collected from non-neurologic horses immediately after euthanasia and blood samples from 40 healthy horses that had a range of IFAT antibody titers against S. neurona and N. hughesi. Serial dilutions of whole blood were made in seronegative CSF to generate blood-contaminated CSF with red blood cell (RBC) concentrations ranging from 10 to 100,000 RBCs/microl. The blood-contaminated CSF samples were then tested for antibodies against both pathogens using IFAT. Blood contamination of CSF had no detectable effect on IFAT results for S. neurona or N. hughesi at any serologic titer when the RBC concentration in CSF was or=5) for S. neurona and N. hughesi were detected only when the corresponding serum titers were >or=160 and >or=80, respectively. The IFAT performed on CSF is reliable for testing horses for equine protozoal myeloencephalitis caused by S. neurona or N. hughesi, even when blood contamination causes the RBC concentration in CSF to be up to 10,000 RBCs/microl.

  13. Rapid Detection Technology for Pesticides Residues Based on Microelectrodes Impedance Immunosensor

    Directory of Open Access Journals (Sweden)

    Wen Ping Zhao

    2014-09-01

    Full Text Available Compared with conventional methods, electrochemical immunosensors have many advantages, such as low cost, high sensitivity, and rapid detection, and has certain prospects for realizing real-time-monitoring. In this paper, a design of portable pesticide residues detection instrument was presented based on an electrochemical impedance immunosensor. Firstly, we studied on an impedance immunosensor based on interdigitated array microelectrode (IDAM coupled with magnetic nanobeads-antibody conjugates (MNAC for the pesticide detection. Magnetic nanobeads (diameter 150 nm coated with anti-carbofuran antibodies were used for further amplification of the binding reaction between antibody and hapten (carbofuran. Secondly, in order to develop a portable pesticide residue apparatus, we designed the impedance detection electric circuit. Main work included designing and constructing of the system circuit, designing and debugging of the system software and so on. Thirdly, the apparatus was used for the standard pesticides solutions testing combined with immunosensor to test the reliability and stability. The pesticide added standard recovery was more than 70 % and the impedance test error was less than 5 %. The results showed that the proposed instrument had a good consistence compared with the traditional analytical methods. Thus, it would be a promising rapid detection instrument for pesticide residues in agricultural products.

  14. Tabhu: tools for antibody humanization

    DEFF Research Database (Denmark)

    Olimpieri, Pier Paolo; Marcatili, Paolo; Tramontano, Anna

    2015-01-01

    Antibodies are rapidly becoming essential tools in the clinical practice, given their ability to recognize their cognate antigens with high specificity and affinity, and a high yield at reasonable costs in model animals. Unfortunately, when administered to human patients, xenogeneic antibodies can...... elicit unwanted and dangerous immunogenic responses. Antibody humanization methods are designed to produce molecules with a better safety profile still maintaining their ability to bind the antigen. This can be accomplished by grafting the non-human regions determining the antigen specificity...... and time-consuming experiments. Here we present tools for antibody humanization (Tabhu) a web server for antibody humanization. Tabhu includes tools for human template selection, grafting, back-mutation evaluation, antibody modelling and structural analysis, helping the user in all the critical steps...

  15. Characterization of thyroid function and antithyroid antibody tests among Saudis

    Science.gov (United States)

    Jammah, Anwar A.; Alshehri, Anwar S.; Alrakhis, Afaf A.; Alhedaithy, Asma S.; Almadhi, Asma M.; Alkwai, Hala M.; Alhamad, Maram M.; Alzahrani, Saad H.

    2015-01-01

    Objective: To determine the reference intervals for thyroid function tests and the prevalence of thyroid autoimmunity in the Saudi population. Methods: A cross-sectional prospective study was conducted in King Khalid University Hospital, Riyadh, Saudi Arabia from January to June 2013. History and physical examination were obtained. Thyroid-stimulating hormone (TSH), free thyroxine (FT4), and free triiodothyronine (FT3) were measured by Electro-chemiluminescence Immunoassay system-assay. Anti-thyroperoxidase, and anti-thyroglobulin antibodies were measured using enzyme-linked immunosorbent-assay. Subjects with previous or a family history of thyroid disorders, those taking medications affecting thyroid function, pregnant or lactating women, and those with goiter were excluded. Individuals with positive antibodies were excluded from the final analysis of the TSH reference range, but were used to determine the prevalence of thyroid autoimmunity. Results: Out of 337 Saudi subjects initially screened, 132 (aged 13-60 years) were candidates for reference calculation, the mean±standard deviation, and (2.5th-97.5th) percentile of TSH (mIU/L) was 1.96±0.9 (0.59-4.37), for FT4 (pmol/L) was 15.47±1.83 (12.04-19.13), and for FT3 (pmol/L) was 5.22±0.7 (4.07-6.76). The TSH was higher in the antibodies positive group (2.5±1.17 mIU/L) compared with the negative one (1.96±0.9 mIU/L) (pantithyroid antibodies. Conclusion: The TSH reference range was similar to laboratory references. Thyroid antibodies were prevalent in Saudis, necessitating further work in larger scale studies. PMID:25987111

  16. Acute HIV Discovered During Routine HIV Screening With HIV Antigen-Antibody Combination Tests in 9 US Emergency Departments.

    Science.gov (United States)

    White, Douglas A E; Giordano, Thomas P; Pasalar, Siavash; Jacobson, Kathleen R; Glick, Nancy R; Sha, Beverly E; Mammen, Priya E; Hunt, Bijou R; Todorovic, Tamara; Moreno-Walton, Lisa; Adomolga, Vincent; Feaster, Daniel J; Branson, Bernard M

    2018-01-05

    Newer combination HIV antigen-antibody tests allow detection of HIV sooner after infection than previous antibody-only immunoassays because, in addition to HIV-1 and -2 antibodies, they detect the HIV-1 p24 antigen, which appears before antibodies develop. We determine the yield of screening with HIV antigen-antibody tests and clinical presentations for new diagnoses of acute and established HIV infection across US emergency departments (EDs). This was a retrospective study of 9 EDs in 6 cities with HIV screening programs that integrated laboratory-based antigen-antibody tests between November 1, 2012, and December 31, 2015. Unique patients with newly diagnosed HIV infection were identified and classified as having either acute HIV infection or established HIV infection. Acute HIV infection was defined as a repeatedly reactive antigen-antibody test result, a negative HIV-1/HIV-2 antibody differentiation assay, or Western blot result, but detectable HIV ribonucleic acid (RNA); established HIV infection was defined as a repeatedly reactive antigen-antibody test result and a positive HIV-1/HIV-2 antibody differentiation assay or Western blot result. The primary outcomes were the number of new HIV diagnoses and proportion of patients with laboratory-defined acute HIV infection. Secondary outcomes compared reason for visit and the clinical presentation of acute HIV infection. In total, 214,524 patients were screened for HIV and 839 (0.4%) received a new diagnosis, of which 122 (14.5%) were acute HIV infection and 717 (85.5%) were established HIV infection. Compared with patients with established HIV infection, those with acute HIV infection were younger, had higher RNA and CD4 counts, and were more likely to have viral syndrome (41.8% versus 6.5%) or fever (14.3% versus 3.4%) as their reason for visit. Most patients with acute HIV infection displayed symptoms attributable to acute infection (median symptom count 5 [interquartile range 3 to 6]), with fever often

  17. Anxiety in voluntary HIV-antibody testing in pregnancy and its implications for preventive strategies.

    Science.gov (United States)

    Foldspang, A; Hedegaard, M

    1991-06-01

    During a three-month period in 1989, 820 pregnant women attending the antenatal clinic of the Aarhus University Hospital, Denmark, were offered a HIV-antibody test and asked to fill out an anonymous questionnaire about attitudes to HIV-antibody testing; 779 (95.0%) agreed to do so. One hundred and fifty-six women (20.0% of the participants) had been tested on a previous occasion, and 629 (80.7%) accepted the present offer to be tested. The most prevalent reasons to decline testing were indifference to the epidemic (45.3% of those declining), refusal of (further) blood testing (34.7%) and fear of being infected (16.7%). Women who consented to be tested most often expressed fear of being infected (21.8%). Fear of registration worried less than 5% of study group members; only 1% declined to be tested because of such worry. The pattern of worries expressed by the pregnant women is interpreted as one of anxiety and, in part at least, perplexity as concerns how to take rational consequences of public messages about the HIV epidemic. It is suggested that future surveillance be based primarily on voluntary testing and, whenever needed and possible, supplied with anonymous unlinked testing of existing blood samples from groups and persons declining to be tested. Such surveillance strategies should be supported in individual patient contacts and public health educational campaigns underscoring the risk of heterosexual transmission of HIV and the need for repeated HIV-antibody testing of selected groups and individuals.

  18. Antibody responses of cervids (Cervus elaphus) following experimental Mycobacterium bovis infection and the implications for immunodiagnosis.

    Science.gov (United States)

    Harrington, Noel P; Surujballi, Om P; Prescott, John F; Duncan, J Robert; Waters, W Ray; Lyashchenko, Konstantin; Greenwald, Rena

    2008-11-01

    Captive and free-ranging wildlife animals are implicated in the maintenance and transmission of bovine tuberculosis and therefore pose a significant obstacle to eradication of the disease from domestic livestock. The current antemortem diagnostic method, the intradermal tuberculin skin test, is impractical for routine use with many wild animals. Antibody-based assays are particularly attractive because the animals are handled only once and immediate processing of the sample is not required. This report characterizes the antibody responses of red deer-elk hybrids (Cervus elaphus) against Mycobacterium bovis and subsequently evaluates the diagnostic performance of select antigens in a rapid-test format. Sequential serum samples were collected from 10 animals experimentally infected with M. bovis and 5 noninfected animals over a 7-month period postinfection (p.i.). Samples were evaluated by enzyme-linked immunosorbent assays, immunoblot analyses, and multiantigen print immunoassays for seroreactivity to mycobacterial antigens. Although all infected animals produced antibodies to M. bovis protein antigens, there was significant animal-to-animal variation in the kinetics and magnitudes of responses and the antigens recognized. The most frequently recognized antigens included MPB83, ESAT-6, CFP10, and MPB70. Responses to some antigens, such as MPB83, were consistently detected as early as 4 weeks after inoculation, whereas other antigens were detected only much later (>140 days p.i.). Antibody responses were boosted by injection of tuberculin for intradermal tuberculin skin testing. Comparison of single-antigen (fluorescence polarization assay) with multiantigen (CervidTB STAT-PAK) rapid tests demonstrated that a highly sensitive and specific serodiagnostic test for tuberculosis in cervids will require multiple and carefully selected seroreactive antigens covering a broad spectrum of antibody specificities.

  19. Buffer substitution in malaria rapid diagnostic tests causes false-positive results

    Directory of Open Access Journals (Sweden)

    Van den Ende Jef

    2010-07-01

    Full Text Available Abstract Background Malaria rapid diagnostic tests (RDTs are kits that generally include 20 to 25 test strips or cassettes, but only a single buffer vial. In field settings, laboratory staff occasionally uses saline, distilled water (liquids for parenteral drugs dilution or tap water as substitutes for the RDT kit's buffer to compensate for the loss of a diluent bottle. The present study assessed the effect of buffer substitution on the RDT results. Methods Twenty-seven RDT brands were run with EDTA-blood samples of five malaria-free subjects, who were negative for rheumatoid factor and antinuclear antibodies. Saline, distilled water and tap water were used as substitute liquids. RDTs were also run with distilled water, without adding blood. Results were compared to those obtained with the RDT kit's buffer and Plasmodium positive samples. Results Only eight cassettes (in four RDT brands showed no control line and were considered invalid. Visible test lines occurred for at least one malaria-free sample and one of the substitutes in 20/27 (74% RDT brands (saline: n = 16; distilled water: n = 17; and tap water: n = 20, and in 15 RDTs which were run with distilled water only. They occurred for all Plasmodium antigens and RDT formats (two-, three- and four-band RDTs. Clearance of the background of the strip was excellent except for saline. The aspects (colour, intensity and crispness of the control and the false-positive test lines were similar to those obtained with the RDT kits' buffer and Plasmodium positive samples. Conclusion Replacement of the RDT kit's dedicated buffer by saline, distilled water and tap water can cause false-positive test results.

  20. Analysis of the Rapid Chloride Migration test

    NARCIS (Netherlands)

    Spiesz, P.R.; Ballari, M.; Brouwers, H.J.H.; Ferreira, R. M.; Gulikers, J.; Andrade, C.

    2009-01-01

    In this study the Rapid Chloride Migration test (RCM) standardized as NT Build 492 and BAW-Merkblatt is reviewed. Since the traditional natural diffusion tests are laborious, time consuming and costly, they are not always preferred from a practical point of view. To overcome these disadvantages,

  1. Micro solid-phase radioimmunoassay for detection of herpesvirus type-specific antibody: specificity and sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Adler-Storthz, K.; Matson, D.O.; Adam, E.; Dreesman, G.R. (Baylor Univ., Houston, TX (USA). Coll. of Medicine)

    1983-02-01

    The specificity and sensitivity of a micro solid-phase radioimmunoassay (micro-SPRIA) that detects type-specific IgG antibody to herpes simplex virus types 1 and 2 (HSV1 and HSV2) were evaluated. Glycoproteins VP123 (molecular weight, 123,000) of HSV1 and VP119 (molecular weight, 119,000) of HSV2 were found to display the greatest degree of antigenic type-specificity of several HSV antigens tested with the micro-SPRIA technique. When testing a group of sera, negative for anti-HSV antibodies by microneutralization, in the micro-SPRIA, a range of negative reactivities was noted, suggesting that cut-points should be determined for each antigen preparation. The micro-SPRIA detected appropriate antibody activity in patients with recurrent infection and a marked agreement was noted in comparison to detection of anti-HSV antibodies measured with the microneutralization test. The type-specificity of the micro-SPRIA was substantiated by the independence of test results using VP119 and VP123 antigens for a random group of positive sera. The assay is rapid, specific, and sensitive and allows the testing of multiple serum samples with a standardized set of reagents.

  2. Serum auto-antibody testing for early diagnosis of breast cancer

    International Nuclear Information System (INIS)

    Parvez, S.

    2012-01-01

    The aim of this thesis is generate prototype-tests suitable for randomized prospective validation of auto-antibody based diagnostic testing using serum samples. Tumours can stimulate the production of auto-antibodies against autologous cellular proteins known as TAAs (tumour associated antigens). This discovery has lead to a possibility of using the auto-antibodies as serological tools for the early diagnosis and management of breast cancer. The recombinant proteins expressed by the SEREX clones, identified from screenings of brain and lung tumour, were used for the production of the protein microarrays and macroarrays. The protein microarrays showed better correlation between the replicates of the serum samples used. The optimized protocols were used for the subsequent experiments. A sizable panel of 642 clone-proteins was selected by marker-screening on protein macroarrays with 38000 clones. These 642 clone-proteins were used to generate protein microarrays that differentiated serum samples from breast cancer patients and controls. Antigenic peptide motifs were identified by in-silico analysis of 642 clone-proteins and peptide arrays were generated using synthetically generated peptides. Comparative studies between protein microarrays and peptide microarrays were done using breast cancer and healthy control samples. Simultaneously, SEREX strategy was used for the identification of the immunogenic TAAs. I identified 192 cDNA expression clones derived from breast cancer tissue samples and the selection was done using breast cancer sera. The genes corresponding to these clones were found over-represented for the pathways that are known to be associated with cancers. These genes showed typical features of TAAs, like over-expression, mutations and fusion genes. (author)

  3. Comparison of two enzyme-linked immunosorbent assays and one rapid immunoblot assay for detection of herpes simplex virus type 2-specific antibodies in serum

    NARCIS (Netherlands)

    Groen, J; Van Dijk, G; Niesters, H G; Van Der Meijden, W I; Osterhaus, A D

    The sensitivities and specificities of three immunoassays for the detection of herpes simplex virus type 2 (HSV-2)-specific immunoglobulin G antibodies in serum, including the one-strip rapid immunoblot assay (RIBA; Chiron Corporation) and two indirect enzyme immunosorbent assays (EIA; Gull

  4. Diagnostic Value of ELISA Tests for the Detection of Specific Antibodies in Cats and Rabbits with Dermatophytosis

    Directory of Open Access Journals (Sweden)

    Marinka Drobnič-Košorok

    2002-01-01

    Full Text Available Two indirect ELISA tests developed for the detection of specific IgG in cats and rabbits, infected with M. canis and T. mentagrophytes, respectively, were evaluated and compared. The levels of specific antibodies were determined in sera of 20 cats and 25 rabbits naturally infected with M. canis and T. mentagrophytes, respectively. Infection was confirmed by the results of fungal culture. Blood samples from 12 cats and 17 rabbits, previously unexposed to dermatophytes, served as negative controls. A significant increase in the level of specific antibodies in groups of infected animals was demonstrated. Sensitivity, specificity and predictive values of a positive and a negative test were determined to evaluate the diagnostic potential. ELISA for the detection of specific antibodies in cats infected with M. canis (ELISA-cats test exhibited 75.0 % of sensitivity at 91.7 % of specificity, whereas the test for the detection of specific antibodies in rabbits, infected with T. mentagrophytes (ELISA-rabbits test is highly sensitive (96.0 % and highly specific (94.1 %, confirming its encouraging diagnostic potential. The cross-reactivity of fungal antigens was tested by performing the assays with antigens M. canis, T. mentagrophytes, M. pachydermatis and A. fumigatus. There were no significant indications of cross-reactions in the test T. mentagrophytes-rabbits, whereas strong cross-reaction between dermatophyte antigens was observed in the test M. canis-cats.

  5. Anti-hLAMP2-antibodies and dual positivity for anti-GBM and MPO-ANCA in a patient with relapsing pulmonary-renal syndrome

    Directory of Open Access Journals (Sweden)

    Kistler Thomas

    2011-06-01

    Full Text Available Abstract Background Pulmonary-renal syndrome associated with anti-glomerular basement membrane (GBM antibodies, also known as Goodpasture's syndrome, is a rare but acute and life-threatening condition. One third of patients presenting as anti-GBM antibody positive pulmonary-renal syndrome or rapidly progressive glomerulonephritis are also tested positive for anti-neutrophil cytoplasmic antibodies (ANCA. Whilst anti-GBM disease is considered a non-relapsing condition, the long-term course of double-positive patients is less predictable. Case Presentation We report a patient with such dual positivity, who presented with pulmonary hemorrhage, crescentic glomerulonephritis and membranous nephropathy. Plasmapheresis in combination with immunosuppresive therapy led to a rapid remission but the disease relapsed after two years. The serum of the patient was tested positive for antibodies to human lysosomal membrane protein 2 (hLAMP2, a novel autoantigen in patients with active small-vessel vasculitis (SVV. The anti-hLAMP2 antibody levels correlated positively with clinical disease activity in this patient. Conclusion We hypothesize that this antibody may indicate a clinical course similar to ANCA-associated vasculitis in double-positive patients. However, this needs to be confirmed on comprehensive patient cohorts.

  6. Potential for false positive HIV test results with the serial rapid HIV testing algorithm.

    Science.gov (United States)

    Baveewo, Steven; Kamya, Moses R; Mayanja-Kizza, Harriet; Fatch, Robin; Bangsberg, David R; Coates, Thomas; Hahn, Judith A; Wanyenze, Rhoda K

    2012-03-19

    Rapid HIV tests provide same-day results and are widely used in HIV testing programs in areas with limited personnel and laboratory infrastructure. The Uganda Ministry of Health currently recommends the serial rapid testing algorithm with Determine, STAT-PAK, and Uni-Gold for diagnosis of HIV infection. Using this algorithm, individuals who test positive on Determine, negative to STAT-PAK and positive to Uni-Gold are reported as HIV positive. We conducted further testing on this subgroup of samples using qualitative DNA PCR to assess the potential for false positive tests in this situation. Of the 3388 individuals who were tested, 984 were HIV positive on two consecutive tests, and 29 were considered positive by a tiebreaker (positive on Determine, negative on STAT-PAK, and positive on Uni-Gold). However, when the 29 samples were further tested using qualitative DNA PCR, 14 (48.2%) were HIV negative. Although this study was not primarily designed to assess the validity of rapid HIV tests and thus only a subset of the samples were retested, the findings show a potential for false positive HIV results in the subset of individuals who test positive when a tiebreaker test is used in serial testing. These findings highlight a need for confirmatory testing for this category of individuals.

  7. Antibody Responses of Cervids (Cervus elaphus) following Experimental Mycobacterium bovis Infection and the Implications for Immunodiagnosis ▿

    Science.gov (United States)

    Harrington, Noel P.; Surujballi, Om P.; Prescott, John F.; Duncan, J. Robert; Waters, W. Ray; Lyashchenko, Konstantin; Greenwald, Rena

    2008-01-01

    Captive and free-ranging wildlife animals are implicated in the maintenance and transmission of bovine tuberculosis and therefore pose a significant obstacle to eradication of the disease from domestic livestock. The current antemortem diagnostic method, the intradermal tuberculin skin test, is impractical for routine use with many wild animals. Antibody-based assays are particularly attractive because the animals are handled only once and immediate processing of the sample is not required. This report characterizes the antibody responses of red deer-elk hybrids (Cervus elaphus) against Mycobacterium bovis and subsequently evaluates the diagnostic performance of select antigens in a rapid-test format. Sequential serum samples were collected from 10 animals experimentally infected with M. bovis and 5 noninfected animals over a 7-month period postinfection (p.i.). Samples were evaluated by enzyme-linked immunosorbent assays, immunoblot analyses, and multiantigen print immunoassays for seroreactivity to mycobacterial antigens. Although all infected animals produced antibodies to M. bovis protein antigens, there was significant animal-to-animal variation in the kinetics and magnitudes of responses and the antigens recognized. The most frequently recognized antigens included MPB83, ESAT-6, CFP10, and MPB70. Responses to some antigens, such as MPB83, were consistently detected as early as 4 weeks after inoculation, whereas other antigens were detected only much later (>140 days p.i.). Antibody responses were boosted by injection of tuberculin for intradermal tuberculin skin testing. Comparison of single-antigen (fluorescence polarization assay) with multiantigen (CervidTB STAT-PAK) rapid tests demonstrated that a highly sensitive and specific serodiagnostic test for tuberculosis in cervids will require multiple and carefully selected seroreactive antigens covering a broad spectrum of antibody specificities. PMID:18815233

  8. Lyme disease antibody

    Science.gov (United States)

    ... JavaScript. The Lyme disease blood test looks for antibodies in the blood to the bacteria that causes ... needed. A laboratory specialist looks for Lyme disease antibodies in the blood sample using the ELISA test . ...

  9. An enzyme-linked immunosorbent assay and a gold-nanoparticle based immuno chromatographic test for amatoxins using recombinant antibody

    International Nuclear Information System (INIS)

    He, Kuo; Zhao, Ruiping; Wang, Lixia; Feng, Tingting; Wei, Dong; Zhang, Xiuyuan

    2016-01-01

    The authors describe two kinds of rapid assays for the determination of amatoxins in mushrooms. The first is an enzyme-linked immunosorbent assay (ELISA) using horseradish peroxidase. The second is a rapid immuno chromatographic assay that uses colloidal gold as a red label (CG-ICA). Both are based on the use of a well-characterized recombinant single chain variable fragment antibody (named scFv-A4). The half-maximum inhibition concentrations (IC50) of α-amanitin, β-amanitin and γ-amanitin are 78, 85 and 90 ng⋅mL"-"1, and the limits of detection (LODs; for IC15) are 1.9, 2.1 and 2.8 ng⋅mL"-"1. The method was applied to the determination of amanitins in mushrooms, and the LODs for α-amanitin, β-amanitin and γ-amanitin in mushroom samples were found to be 4.9, 6.4 and 8.3 ng⋅mL"-"1. The visual minimum detection limits of the optimized CGIA are 4 and 6 ng⋅mL"-"1 for mushroom samples. The test can be performed within 10 min. The results of the analysis of spiked samples showed that the CG-IA can rapidly and semi-quantitatively quantify amatoxins in mushroom samples on site and at low costs. (author)

  10. A simple electroelution method for rapid protein purification: isolation and antibody production of alpha toxin from Clostridium septicum

    Directory of Open Access Journals (Sweden)

    Lorena Vázquez-Iglesias

    2017-06-01

    Full Text Available Clostridium septicum produces a number of diseases in human and farm animals which, in most of the cases, are fatal without clinical intervention. Alpha toxin is an important agent and the unique lethal virulent factor produced by Clostridium septicum. This toxin is haemolytic, highly lethal and necrotizing activities but is being used as an antigen to develop animal vaccines. The aim of this study was to isolate the alpha toxin of Clostridium septicum and produce highly specific antibodies against it. In this work, we have developed a simple and efficient method for alpha toxin purification, based on electroelution that can be used as a time-saving method for purifying proteins. This technique avoids contamination by other proteins that could appear during other protein purification techniques such chromatography. The highly purified toxin was used to produce polyclonal antibodies. The specificity of the antibodies was tested by western blot and these antibodies can be applied to the quantitative determination of alpha toxin by slot blot.

  11. Antibodies from plants for bionanomaterials.

    Science.gov (United States)

    Edgue, Gueven; Twyman, Richard M; Beiss, Veronique; Fischer, Rainer; Sack, Markus

    2017-11-01

    Antibodies are produced as part of the vertebrate adaptive immune response and are not naturally made by plants. However, antibody DNA sequences can be introduced into plants, and together with laboratory technologies that allow the design of antibodies recognizing any conceivable molecular structure, plants can be used as 'green factories' to produce any antibody at all. The advent of plant-based transient expression systems in particular allows the rapid, convenient, and safe production of antibodies, ranging from laboratory-scale expression to industrial-scale manufacturing. The key features of plant-based production include safety, speed, low cost, and convenience, allowing newcomers to rapidly master the technology and use it to its full advantage. Manufacturing in plants has recently achieved significant milestones and offers more than just an alternative to established microbial and mammalian cell platforms. The use of plants for product development in particular offers the power and flexibility to easily coexpress many different genes, allowing the plug-and-play construction of novel bionanomaterials, perfectly complementing existing approaches based on plant virus-like particles. As well as producing single antibodies for applications in medicine, agriculture, and industry, plants can be used to produce antibody-based supramolecular structures and scaffolds as a new generation of green bionanomaterials that promise a bright future based on clean and renewable nanotechnology applications. WIREs Nanomed Nanobiotechnol 2017, 9:e1462. doi: 10.1002/wnan.1462 For further resources related to this article, please visit the WIREs website. © 2017 The Authors. WIREs Nanomedicine and Nanobiotechnology published by Wiley Periodicals, Inc.

  12. Assessment of the rapid test based on an immunochromatography technique for detecting anti-Treponema pallidum antibodies Avaliação do teste rápido para a detecção de anticorpos anti-Treponema pallidum baseado na técnica de imunocromatografia

    Directory of Open Access Journals (Sweden)

    Neuza Satomi Sato

    2003-12-01

    Full Text Available A rapid test based on an immunochromatography assay - Determine™ Syphilis TP (Abbott Lab. for detecting specific antibodies to Treponema pallidum was evaluated against serum samples from patients with clinical, epidemiological and serological diagnosis of syphilis, patients with sexually transmitted disease other than syphilis, and individuals with negative serology for syphilis. The Determine™ test presented the sensitivity of 93.6%, specificity of 92.5%, and positive predictive value and negative predictive value of 95.2% and 93.7%, respectively. One serum sample from patient with recent latent syphilis showed a prozone reaction. Determine™ is a rapid assay, highly specific and easy to perform. This technique obviates the need of equipment and its diagnostic features demonstrate that it may be applicable as an alternative assay for syphilis screening under some emergency conditions or for patients living in remote localities.O desempenho do teste rápido imunocromatográfico de procedência comercial Determine™ Syphilis TP (Abbott Lab. para detectar anticorpos específicos contra antígenos treponêmicos foi avaliado com soros de pacientes tendo diagnóstico epidemiológico, clínico e laboratorial de sífilis, de pacientes com outras doenças sexualmente transmissíveis e de indivíduos clinicamente sadios ou com resultados negativos nos testes sorológicos para sífilis. Os valores de sensibilidade e de especificidade do teste Determine™ foram respectivamente de 93,6% e 95,2%, o valor preditivo positivo foi de 95,2% e o valor preditivo negativo 93,6%. O fenômeno de prozona foi observado em uma amostra de paciente com sífilis recente latente. O teste é de fácil e rápida execução, sem necessidade de equipamentos e o resultado pode ser obtido em 15 minutos, que de acordo com suas características diagnósticas poderá ser utilizado como teste alternativo de triagem em determinadas situações de emergência ou em pacientes que vivem

  13. When should we test for voltage-gated potassium channel complex antibodies? A retrospective case control study.

    Science.gov (United States)

    O'Sullivan, B J; Steele, T; Ellul, M A; Kirby, E; Duale, A; Kier, G; Crooks, D; Jacob, A; Solomon, T; Michael, B D

    2016-11-01

    Patients with voltage-gated potassium channel (VGKC)-complex antibodies are increasingly recognized as having central, peripheral or combined phenotypes. With increasing awareness, more patients are tested and the clinical spectrum is expanding. Consequently, clinicians may be uncertain as to which patients should or should not be tested. Previous studies have identified common clinical features, but none has looked at the usefulness of these in predicting seropositive disease. We conducted a case-control study of patients tested for VGKC-complex antibodies over 10years at a regional tertiary neurology centre determining which clinical/biochemical features were associated with antibody-positive disease. We found a marked increase in the numbers tested, although the percentage positive remained low. Antibody titre was highest in central disease (pVGKC-disease (p=0.01). Seizures were present in 11 (69%) of those with VGKC-disease versus three (18%) without (odds ratio [OR] 10.3, 95% confidence interval [CI]: 2.0-52.7, p=0.005). There was an inverse correlation between the antibody titre and serum sodium. A multivariate model selected seizures and hyponatraemia as predictive of VGKC disease (sensitivity 75% and specificity 82%); faciobrachial dystonic movements were specific but insensitive. Interestingly serum alkaline phosphatase was higher in those with VGKC-disease (p=0.016) and highest in those with peripheral disease (p=0.015). An ALP>70u/L was strongly associated with antibody positivity (OR 4.11 95% CI: 1.43-11.8, p=0.007) with a sensitivity of 74.2%. The presence of seizures, faciobrachial movements, and hyponatraemia should raise suspicion of VGKC-disease; alkaline phosphatase may represent a novel biomarker, particularly in those with peripheral disease. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Will gay and bisexually active men at high risk of infection use over-the-counter rapid HIV tests to screen sexual partners?

    Science.gov (United States)

    Carballo-Diéguez, Alex; Frasca, Timothy; Dolezal, Curtis; Balan, Ivan

    2012-01-01

    The Food and Drug Administration may license OraQuick™, a rapid HIV test, for over-the-counter (OTC) sale. This study investigated whether HIV-uninfected, non-monogamous, gay and bisexual men who never or rarely use condoms would use the test with partners as a harm-reduction approach. Sixty participants responded to two computer-assisted self-interviews, underwent an in-depth interview, and chose whether to test themselves with OraQuick. Over 80% of the men said they would use the kit to test sexual partners or themselves if it became available OTC. Most participants understood that antibody tests have a window period in which the virus is undetectable, yet saw advantages to using the test to screen partners; 74% tested themselves in our offices. Participants offered several possible strategies to introduce the home-test idea to partners, frequently endorsed mutual testing, and highlighted that home testing could stimulate greater honesty in serostatus disclosure. Participants drew distinctions between testing regular versus occasional partners. Non-monogamous men who have sex with men, who never or rarely use condoms, may nevertheless seek to avoid HIV. Technologies that do not interfere with sexual pleasure are likely to be used when available. Studies are needed to evaluate the advantages and disadvantages of using OTC rapid HIV tests as one additional harm-reduction tool.

  15. Immunodiagnosis of paracoccidioidomycosis due to Paracoccidioides brasiliensis using a latex test: detection of specific antibody anti-gp43 and specific antigen gp43.

    Directory of Open Access Journals (Sweden)

    Priscila Oliveira Dos Santos

    2015-02-01

    Full Text Available Paracoccidioidomycosis (PCM is a life-threatening systemic disease and is a neglected public health problem in many endemic regions of Latin America. Though several diagnostic methods are available, almost all of them present with some limitations.A latex immunoassay using sensitized latex particles (SLPs with gp43 antigen, the immunodominant antigen of Paracoccidioides brasiliensis, or the monoclonal antibody mAb17c (anti-gp43 was evaluated for antibody or antigen detection in sera, cerebrospinal fluid (CSF, and bronchoalveolar lavage (BAL from patients with PCM due to P. brasiliensis. The gp43-SLPs performed optimally to detect specific antibodies with high levels of sensitivity (98.46%, 95% CI 91.7-100.0, specificity (93.94%, 95% CI 87.3-97.7, and positive (91.4% and negative (98.9% predictive values. In addition, we propose the use of mAb17c-SLPs to detect circulating gp43, which would be particularly important in patients with immune deficiencies who fail to produce normal levels of immunoglobulins, achieving good levels of sensitivity (96.92%, 95% CI 89.3-99.6, specificity (88.89%, 95% CI 81.0-94.3, and positive (85.1% and negative (97.8% predictive values. Very good agreement between latex tests and double immune diffusion was observed for gp43-SLPs (k = 0.924 and mAb17c-SLPs (k = 0.850, which reinforces the usefulness of our tests for the rapid diagnosis of PCM in less than 10 minutes. Minor cross-reactivity occurred with sera from patients with other fungal infections. We successfully detected antigens and antibodies from CSF and BAL samples. In addition, the latex test was useful for monitoring PCM patients receiving therapy.The high diagnostic accuracy, low cost, reduced assay time, and simplicity of this new latex test offer the potential to be commercialized and makes it an attractive diagnostic assay for use not only in clinics and medical mycology laboratories, but mainly in remote locations with limited laboratory infrastructure

  16. Potential for false positive HIV test results with the serial rapid HIV testing algorithm

    Directory of Open Access Journals (Sweden)

    Baveewo Steven

    2012-03-01

    Full Text Available Abstract Background Rapid HIV tests provide same-day results and are widely used in HIV testing programs in areas with limited personnel and laboratory infrastructure. The Uganda Ministry of Health currently recommends the serial rapid testing algorithm with Determine, STAT-PAK, and Uni-Gold for diagnosis of HIV infection. Using this algorithm, individuals who test positive on Determine, negative to STAT-PAK and positive to Uni-Gold are reported as HIV positive. We conducted further testing on this subgroup of samples using qualitative DNA PCR to assess the potential for false positive tests in this situation. Results Of the 3388 individuals who were tested, 984 were HIV positive on two consecutive tests, and 29 were considered positive by a tiebreaker (positive on Determine, negative on STAT-PAK, and positive on Uni-Gold. However, when the 29 samples were further tested using qualitative DNA PCR, 14 (48.2% were HIV negative. Conclusion Although this study was not primarily designed to assess the validity of rapid HIV tests and thus only a subset of the samples were retested, the findings show a potential for false positive HIV results in the subset of individuals who test positive when a tiebreaker test is used in serial testing. These findings highlight a need for confirmatory testing for this category of individuals.

  17. Evaluation Of Algorithms Of Anti- HIV Antibody Tests

    Directory of Open Access Journals (Sweden)

    Paranjape R.S

    1997-01-01

    Full Text Available Research question: Can alternate algorithms be used in place of conventional algorithm for epidemiological studies of HIV infection with less expenses? Objective: To compare the results of HIV sero- prevalence as determined by test algorithms combining three kits with conventional test algorithm. Study design: Cross â€" sectional. Participants: 282 truck drivers. Statistical analysis: Sensitivity and specificity analysis and predictive values. Results: Three different algorithms that do not include Western Blot (WB were compared with the conventional algorithm, in a truck driver population with 5.6% prevalence of HIV â€"I infection. Algorithms with one EIA (Genetic Systems or Biotest and a rapid test (immunocomb or with two EIAs showed 100% positive predictive value in relation to the conventional algorithm. Using an algorithm with EIA as screening test and a rapid test as a confirmatory test was 50 to 70% less expensive than the conventional algorithm per positive scrum sample. These algorithms obviate the interpretation of indeterminate results and also give differential diagnosis of HIV-2 infection. Alternate algorithms are ideally suited for community based control programme in developing countries. Application of these algorithms in population with low prevalence should also be studied in order to evaluate universal applicability.

  18. Detection of serum anti-sperm antibody in infertile couples with dot-immunogold filtration assay (DIGFA)

    International Nuclear Information System (INIS)

    Xie Xiaoxian

    2005-01-01

    Objective: To develop a new method for rapid detection of serum anti-sperm antibody in infertile couples. Methods: Human sperm antigen was prepared from pooled semen specimens of fertile males. Nitro-cellulose membrane was used as solid-phase carrier of the antigen. Colloidal gold pellet combined goat anti-human IgG was taken as labelled antibody. A dot-immunogold filtration assay system was established for test of serum anti-human sperm antibody. Serum specimens from 137 infertile couples were tested and the result compared with flat from ELISA. Results: The human sperm antigen would react with the anti-sperm antibody in the tested serum over the cellulose membrane through filtration and the result could be read with naked eye within 6 minutes. In this study of 137 infertile coupled, the anti-sperm antibody was positive in 21.9% of the female serum specimens and 13.19% of the males. Compared with the result from ELISA, the consistency rate was 96.1%. The sensitivity of the assay was 90.2% and specificity was 95.4%. The p reparation was stable after 6 months refrigerator storage. Conclusion: This newly developed DIGFA is very adequate for rap id detection of anti-sperm antibody and deserves popularization. (authors)

  19. Effects of genetic engineering on the pharmacokinetics of antibodies

    International Nuclear Information System (INIS)

    Colcher, D.; Goel, A.; Pavlinkova, G.; Beresford, G.; Booth, B.; Batra, S.K.

    1999-01-01

    Monoclonal antibodies (MAbs) may be considered 'magic bullets' due to their ability to recognize and eradicate malignant cells. MAbs, however, have practical limitations for their rapid application in the clinics. The structure of the antibody molecules can be engineered to modify functional domains such as antigen-binding sites and/or effectors functions. Advanced in genetic engineering have provided rapid progress the development of new immunoglobulin constructs of MAbs with defined research and therapeutic application. Recombinant antibody constructs are being engineered, such as human mouse chimeric, domain-dispositioned, domain-deleted, humanized and single-chain Fv fragments. Genetically-engineered antibodies differ in size and rate of catabolism. Pharmacokinetics studies show that the intact IgG (150 kD), enzymatically derived fragments Fab' (50 kD) and single chain Fv (28 kD) have different clearance rates. These antibody forms clear 50% from the blood pool in 2.1 days, 30 minutes and 10 minutes, respectively. Genetically-engineered antibodies make a new class of immunotherapeutic tracers for cancer treatment

  20. Determination of HIV Status in African Adults With Discordant HIV Rapid Tests.

    Science.gov (United States)

    Fogel, Jessica M; Piwowar-Manning, Estelle; Donohue, Kelsey; Cummings, Vanessa; Marzinke, Mark A; Clarke, William; Breaud, Autumn; Fiamma, Agnès; Donnell, Deborah; Kulich, Michal; Mbwambo, Jessie K K; Richter, Linda; Gray, Glenda; Sweat, Michael; Coates, Thomas J; Eshleman, Susan H

    2015-08-01

    In resource-limited settings, HIV infection is often diagnosed using 2 rapid tests. If the results are discordant, a third tie-breaker test is often used to determine HIV status. This study characterized samples with discordant rapid tests and compared different testing strategies for determining HIV status in these cases. Samples were previously collected from 173 African adults in a population-based survey who had discordant rapid test results. Samples were classified as HIV positive or HIV negative using a rigorous testing algorithm that included two fourth-generation tests, a discriminatory test, and 2 HIV RNA tests. Tie-breaker tests were evaluated, including rapid tests (1 performed in-country), a third-generation enzyme immunoassay, and two fourth-generation tests. Selected samples were further characterized using additional assays. Twenty-nine samples (16.8%) were classified as HIV positive and 24 of those samples (82.8%) had undetectable HIV RNA. Antiretroviral drugs were detected in 1 sample. Sensitivity was 8.3%-43% for the rapid tests; 24.1% for the third-generation enzyme immunoassay; 95.8% and 96.6% for the fourth-generation tests. Specificity was lower for the fourth-generation tests than the other tests. Accuracy ranged from 79.5% to 91.3%. In this population-based survey, most HIV-infected adults with discordant rapid tests were virally suppressed without antiretroviral drugs. Use of individual assays as tie-breaker tests was not a reliable method for determining HIV status in these individuals. More extensive testing algorithms that use a fourth-generation screening test with a discriminatory test and HIV RNA test are preferable for determining HIV status in these cases.

  1. A magnetic particles-based chemiluminescence enzyme immunoassay for rapid detection of ovalbumin.

    Science.gov (United States)

    Feng, Xiao-Li; Ren, Hong-Lin; Li, Yan-Song; Hu, Pan; Zhou, Yu; Liu, Zeng-Shan; Yan, Dong-Ming; Hui, Qi; Liu, Dong; Lin, Chao; Liu, Nan-Nan; Liu, Yan-Yan; Lu, Shi-Ying

    2014-08-15

    Egg allergy is an important public health and safety concern, so quantification and administration of food or vaccines containing ovalbumin (OVA) are urgently needed. This study aimed to establish a rapid and sensitive magnetic particles-chemiluminescence enzyme immunoassay (MPs-CLEIA) for the determination of OVA. The proposed method was developed on the basis of a double antibodies sandwich immunoreaction and luminol-H2O2 chemiluminescence system. The MPs served as both the solid phase and separator, the anti-OVA MPs-coated polyclonal antibodies (pAbs) were used as capturing antibody, and the horseradish peroxidase (HRP)-labeled monoclonal antibody (mAb) was taken as detecting antibody. The parameters of the method were evaluated and optimized. The established MPs-CLEIA method had a linear range from 0.31 to 100ng/ml with a detection limit of 0.24ng/ml. The assays showed low reactivities and less than 5% of intraassay and interassay coefficients of variation (CVs), and the average recoveries were between 92 and 97%. Furthermore, the developed method was applied in real samples analysis successfully, and the correlation coefficient with the commercially available OVA kit was 0.9976. Moreover, it was more rapid and sensitive compared with the other methods for testing OVA. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. Rapid Assessment of Drugs of Abuse.

    Science.gov (United States)

    Wiencek, Joesph R; Colby, Jennifer M; Nichols, James H

    Laboratory testing for drugs of abuse has become standard practice in many settings both forensic and clinical. Urine is the predominant specimen, but other specimens are possible including hair, nails, sweat, and oral fluid. Point-of-care test kits provide for rapid analysis at the site where specimens are collected allowing for immediate action on the results. POCT is based on immunochromatography where the drug in the patient's sample competes with drug and antibody conjugates in the test to develop or block the development of a colored line. Most POCTs are visually interpreted in a few minutes. The potential for false positives is possible due to drug cross-reactivity with the antibodies in the test. False negatives are also possible due to dilution of the sample and the potential for adulteration or sample substitution by the patient. POCT shows more variability than central laboratory testing because of the variety of operators involved in the testing process, but POCT has good agreement for most tests with mass spectrometry provided comparable cutoffs and cross-reactivity of drugs/metabolites are considered. Validation of the test performance with the intended operators will identify potential interferences and operational issues before implementing the test in routine practice. POCT offers faster turnaround of test results provided the limitations and challenges of the test are considered. © 2017 Elsevier Inc. All rights reserved.

  3. DARPA Antibody Technology Program Standardized Test Bed for Antibody Characterization: Characterization of an MS2 Human IgG Antibody Produced by AnaptysBio, Inc.

    Science.gov (United States)

    2016-02-01

    Enzyme- linked immunosorbent assay (ELISA) Quality Testing MS2 coat protein (MS2CP) 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF...primarily relied on the performance of an antibody in an enzyme- linked immunosorbent assay (ELISA), with little regard for quantifying the full spectrum...Protection, and Multi-Year Stabilization, in High Concentration Protein Solutions, Using Ionic Liquids. Chem. Commun. (Camb) 2007, 26, 2714–2716. 3. Bio

  4. Interference of daratumumab with pretransfusion testing, mimicking a high-titer, low avidity like antibody

    Directory of Open Access Journals (Sweden)

    Mei-Hwa Lin

    2017-01-01

    Full Text Available Daratumumab is a monoclonal immunoglobulin against CD38 and has been approved for treating patients with refractory multiple myeloma. The presence of daratumumab in the sera can interfere with pretransfusion testing due to the weakly expression of CD38 on red cells. The reactivity could be mistaken as autoantibody (if autocontrol is positive or alloantibody (if autocontrol is negative. We present a case that demonstrates daratumumab could mimic a high titer low avidity (HTLA alloantibody. A 34-year-old male patient of refractory myeloma was recruited in phase three clinical trial involving daratumumab. Samples were sent to the blood bank for pretransfusion testing. Without knowledge of patient having used daratumumab, we mistook the reactivity in the patient's sera as an HTLA antibody due to the results of negative autocontrol and high titers of antibody activity. Antibody screen showed a panreactive pattern and the reactivity against screening cells was up to a titer of 1: 1240. The reactivity was weaker against cord cells than adult cells, became weaker against ZZAP-treated cells and became negative against DDT-treated cells. A discussion with attending physician finally revealed the reactivity was due to the interference caused by daratumumab. The case demonstrates good communication is essential in performing pretransfusion testing for patients receiving daratumumab and other new biological regimens that can interfere with compatibility test.

  5. Centrifuge modeling of rapid load tests with open-ended piles

    NARCIS (Netherlands)

    Nguyen, T.C.; Van Lottum, H.; Holscher, P.; Van Tol, A.F.

    2012-01-01

    Rapid and static load tests were conducted on open-ended and close-ended piles in the Deltares GeoCentriflige. hi flight, a pile was driven into the soil. Both fme-grained sand and silt beds were tested. Both the rapid and static soil resistances o f a close-ended pile were higher than the soil

  6. A comparison of antibody testing, permeability testing, and zonulin levels with small-bowel biopsy in celiac disease patients on a gluten-free diet.

    Science.gov (United States)

    Duerksen, D R; Wilhelm-Boyles, C; Veitch, R; Kryszak, D; Parry, D M

    2010-04-01

    Active celiac disease is associated with positive endomysial (EMA) and tissue transglutaminase (TTG) antibodies, elevated zonulin levels, and increased intestinal permeability. There is little known about what happens to these immunologic and structural abnormalities in patients on a gluten-free diet and their correlation with small-bowel biopsy changes. Adult patients previously diagnosed with celiac disease and on a gluten-free diet for greater than 1 year were considered for the study. All patients underwent the following: measurement of EMA and TTG antibodies, serum zonulin levels, intestinal permeability (IP) testing with lactulose/mannitol ratios, food diary analysis for gluten ingestion and small- bowel biopsy. A total of 21 patients on a gluten-free diet for a mean of 9.7 years completed the study. There were ten patients who had normalization of intestinal biopsies, IP and TTG, and EM antibodies. Six patients had Marsh type 2 or 3 lesions and all had either abnormal IP (5/6) or TTG antibody (4/6). In patients with Marsh type 3 lesions, there was a correlation between IP and zonulin levels. A subgroup of patients with celiac disease on a gluten-free diet has complete normalization of intestinal biopsies, intestinal permeability defects, and antibody levels. Patients with Marsh type 3 lesions have abnormal TTG antibodies and intestinal permeability with zonulin levels that correlate with IP. These abnormalities may be due to continued gluten ingestion. Further study is needed to determine the clinical utility of TTG antibodies and IP testing in following patients with celiac disease.

  7. Determination of antibody levels to Candida albicans in healthy and hospitalised adults using a radioimmunoassay

    International Nuclear Information System (INIS)

    Cobb, S.J.; Parratt, D.

    1978-01-01

    A radioimmunoassay for antibody to Candida albicans is described. The test uses whole, killed of organisms as the antigen and radiolabelled sheep anti-human globulins to quantitate different classes of antibody to C. albicans. The assay has been compared with an Ouchterlony precipitin method and found to be simpler, more rapid, and more sensitive than the latter. Results obtained from two groups of symptomless adults indicated that the range of antibody level was wider for a hospitalised group than for a group of blood transfusion donors, particularly in respect of IgG and IgA antibody. The reason for the increase of antibody in hospital patients was not clear but may have been related to antibiotic therapy. The difficulties in interpretation of Candida serology have therefore been re-assessed in the light of more detailed knowledge of the range and type of antibody to be expected in normal individuals. (author)

  8. A rapid one-step radiometric assay for hepatitis B surface antigen utilising monoclonal antibodies

    International Nuclear Information System (INIS)

    Goodall, A.H.; Meek, F.L.; Waters, J.A.; Miescher, G.C.; Janossy, G.; Thomas, H.C.

    1982-01-01

    A two-site antigen assay for HBsAg has been developed that employs 3 monoclonal antibodies. The antibodies were selected for their high affinity and their particular epitope specificity to establish an assay with a sensitivity for the antigen comparable with that of a conventional assay with heterologous antisera. In addition, by selecting a monoclonal antibody for use as a tracer which does not compete for antigenic binding sites with the solid-phase monoclonal antibodies, it has been possible to perform a two-site assay in a single 1 h incubation step, achieving the same degree of sensitivity. This principle of using monoclonal antibodies in a one-step assay therefore gives advantages of speed and simplicity over assays using heterologous antisera and would be applicable to a variety of antigen assays for which appropriate monoclonal antibodies are available. (Auth.)

  9. A rapid, sensitive and reliable diagnostic test for scrub typhus in China

    Directory of Open Access Journals (Sweden)

    Zhang Lijuan

    2011-01-01

    Full Text Available Purpose: To evaluate the performances for detection of IgM and IgG antibodies to Orientia. tsutsugamushi (Ot using a gold conjugate-based rapid diagnostic test (RDT. Materials and Methods: The RDT employing mixture recombinant 56-kDa proteins of O. tsutsugamushi and the mIFA assay was performed on 33 patients from Fujian and Yunnan province respectively and 94 positive sera (36 from Hainan province and 58 from Jiangsu province from convalescent stages of the patients with scrub typhus respectively and 82 negative sera from healthy farmers from Anhui province and Beijing City respectively in 2009. A comparison of the RDT and mIFA assay was performed by using the c2 test and the P level of ≤0.05 was considered to be significant. Results: Among these 94 positive sera from convalescent stages of the illness and 82 sera from control farmers, the specificity of RDT was 100% for both IgM and IgG tests. In 33 cases with scrub typhus, 5 cases were positively detected earlier by RDT than by mIFA for the IgM test, and 2 cases were positive for the IgG test. The sensitivities of RDT were 93.9% and 90.9% for IgM and IgG, respectively. Considering IgM and IgG together, the sensitivity was 100%. The geometric mean titre (GMT of IFA and the RDT assay in diluted sera from confirmed cases were 1:37 versus 1:113 respectively (P<0.001 for IgM test and 1:99 versus 1:279 respectively (P<0.016 for IgG. Conclusions: The RDT was more sensitive than the traditional IFA for the early diagnosis of scrub typhus and was particularly suitable for use in rural areas.

  10. Prospective evaluation of three rapid diagnostic tests for diagnosis of human leptospirosis.

    Directory of Open Access Journals (Sweden)

    Marga G A Goris

    Full Text Available BACKGROUND: Diagnosis of leptospirosis by the microscopic agglutination test (MAT or by culture is confined to specialized laboratories. Although ELISA techniques are more common, they still require laboratory facilities. Rapid Diagnostic Tests (RDTs can be used for easy point-of-care diagnosis. This study aims to evaluate the diagnostic performance of the RDTs LeptoTek Dri Dot, LeptoTek Lateral Flow, and Leptocheck-WB, prospectively. METHODOLOGY: During 2001 to 2012, one or two of the RDTs at the same time have been applied prior to routine diagnostics (MAT, ELISA and culture on serum specimens from participants sent in for leptospirosis diagnosis. The case definition was based on MAT, ELISA and culture results. Participants not fulfilling the case definition were considered not to have leptospirosis. The diagnostic accuracy was determined based on the 1(st submitted sample and paired samples, either in an overall analysis or stratified according to days post onset of illness. RESULTS: The overall sensitivity and specificity for the LeptoTek Dri Dot was 75% respectively 96%, for the LeptoTek Lateral Flow 78% respectively 95%, and for the Leptocheck-WB 78% respectively 98%. Based on the 1(st submitted sample the sensitivity was low (51% for LeptoTek Dri Dot, 69% for LeptoTek Lateral Flow, and 55% for Leptocheck-WB, but substantially increased when the results of paired samples were combined, although accompanied by a lower specificity (82% respectively 91% for LeptoTek Dri Dot, 86% respectively 84% for LeptoTek Lateral Flow, and 80% respectively 93% for Leptocheck-WB. CONCLUSIONS: All three tests present antibody tests contributing to the diagnosis of leptospirosis, thus supporting clinical suspicion and contributing to awareness. Since the overall sensitivity of the tested RDTs did not exceed 80%, one should be cautious to rely only on an RDT result, and confirmation by reference tests is strongly recommended.

  11. Should we systematically test patients with clinically isolated syndrome for auto-antibodies?

    Science.gov (United States)

    Negrotto, Laura; Tur, Carmen; Tintoré, Mar; Arrambide, Georgina; Sastre-Garriga, Jaume; Río, Jordi; Comabella, Manuel; Nos, Carlos; Galán, Ingrid; Vidal-Jordana, Angela; Simon, Eva; Castilló, Joaquín; Palavra, Filipe; Mitjana, Raquel; Auger, Cristina; Rovira, Àlex; Montalban, Xavier

    2015-12-01

    Several autoimmune diseases (ADs) can mimic multiple sclerosis (MS). For this reason, testing for auto-antibodies (auto-Abs) is often included in the diagnostic work-up of patients with a clinically isolated syndrome (CIS). The purpose was to study how useful it was to systematically determine antinuclear-antibodies, anti-SSA and anti-SSB in a non-selected cohort of CIS patients, regarding the identification of other ADs that could represent an alternative diagnosis. From a prospective CIS cohort, we selected 772 patients in which auto-Ab levels were tested within the first year from CIS. Baseline characteristics of auto-Ab positive and negative patients were compared. A retrospective revision of clinical records was then performed in the auto-Ab positive patients to identify those who developed ADs during follow-up. One or more auto-Ab were present in 29.4% of patients. Only 1.8% of patients developed other ADs during a mean follow-up of 6.6 years. In none of these cases the concurrent AD was considered the cause of the CIS. In all cases the diagnosis of the AD resulted from the development of signs and/or symptoms suggestive of each disease. Antinuclear-antibodies, anti-SSA and anti-SSB should not be routinely determined in CIS patients but only in those presenting symptoms suggestive of other ADs. © The Author(s), 2015.

  12. Antibodies and Selection of Monoclonal Antibodies.

    Science.gov (United States)

    Hanack, Katja; Messerschmidt, Katrin; Listek, Martin

    Monoclonal antibodies are universal binding molecules with a high specificity for their target and are indispensable tools in research, diagnostics and therapy. The biotechnological generation of monoclonal antibodies was enabled by the hybridoma technology published in 1975 by Köhler and Milstein. Today monoclonal antibodies are used in a variety of applications as flow cytometry, magnetic cell sorting, immunoassays or therapeutic approaches. First step of the generation process is the immunization of the organism with appropriate antigen. After a positive immune response the spleen cells are isolated and fused with myeloma cells in order to generate stable, long-living antibody-producing cell lines - hybridoma cells. In the subsequent identification step the culture supernatants of all hybridoma cells are screened weekly for the production of the antibody of interest. Hybridoma cells producing the antibody of interest are cloned by limited dilution till a monoclonal hybridoma is found. This is a very time-consuming and laborious process and therefore different selection strategies were developed since 1975 in order to facilitate the generation of monoclonal antibodies. Apart from common automation of pipetting processes and ELISA testing there are some promising approaches to select the right monoclonal antibody very early in the process to reduce time and effort of the generation. In this chapter different selection strategies for antibody-producing hybridoma cells are presented and analysed regarding to their benefits compared to conventional limited dilution technology.

  13. A Lateral Flow Protein Microarray for Rapid and Sensitive Antibody Assays

    Directory of Open Access Journals (Sweden)

    Helene Andersson-Svahn

    2011-11-01

    Full Text Available Protein microarrays are useful tools for highly multiplexed determination of presence or levels of clinically relevant biomarkers in human tissues and biofluids. However, such tools have thus far been restricted to laboratory environments. Here, we present a novel 384-plexed easy to use lateral flow protein microarray device capable of sensitive (< 30 ng/mL determination of antigen-specific antibodies in ten minutes of total assay time. Results were developed with gold nanobeads and could be recorded by a cell-phone camera or table top scanner. Excellent accuracy with an area under curve (AUC of 98% was achieved in comparison with an established glass microarray assay for 26 antigen-specific antibodies. We propose that the presented framework could find use in convenient and cost-efficient quality control of antibody production, as well as in providing a platform for multiplexed affinity-based assays in low-resource or mobile settings.

  14. Radioimmunoassay with heterologous antibody (hetero-antibody RIA)

    International Nuclear Information System (INIS)

    Iwasawa, Atsushi; Hayashi, Hiroaki; Itoh, Zen; Wakabayashi, Katsumi

    1991-01-01

    To develop a homologous radioimmunoassay (RIA) for a hormone of a small or rare animal often meets difficulty in collecting a large amount of purified antigen required for antibody production. On the other hand, to employ a heterologous RIA to estimate the hormone often gives poor sensitivity. To overcome this difficulty, a 'hetero-antibody' RIA was studied. In a hetero-antibody RIA system, a purified preparation of a hormone is used for radioiodination and standardization and a heterologous antibody to the hormone is used for the first antibody. Canine motilin and rat LH were selected as examples, and anti-porcine motilin and anti-hCG, anti-hCGβ or anti-ovine LHβ was used as the heterologous antibody. The sensitivities of the hetero-antibody RIAs were much higher than those of heterologous RIAs in any case, showing that these hetero-antibody RIA systems were suitable for practical use. To clarify the principle of hetero-antibody RIA, antiserum to porcine motilin was fractionated on an affinity column where canine motilin was immobilized. The fraction bound had greater constants of affinity with both porcine and canine motilins than the rest of the antibody fractions. This fraction also reacted with a synthetic peptide corresponding to the C-terminal sequence common to porcine and canine motilins in a competitive binding test with labeled canine motilin. These results suggest that an antibody population having high affinity and cross-reactivity is present in polyclonal antiserum and indicate that the population can be used in hetero-antibody RIA at an appropriate concentration. (author)

  15. A serial study of anticardiolipin antibody and antimitochondrial antibody type M5 in a patient with polyarthritis and polymyositis.

    Science.gov (United States)

    Keane, A; Woods, R; Foley-Nolan, D; Roden, D; Coughlan, R; Barry, C

    1989-04-01

    A 22-year-old female presented with polyarthritis and subsequent polymyositis. Initially, she had moderately high levels of anticardiolipin (aCl) and antimitochondrial antibody (AMA) type M5. Following corticosteroid therapy, the anticardiolipin antibody rapidly fell to background levels but reappeared with the onset of two significant clinical events.

  16. Improvement of western blot test specificity for detecting equine serum antibodies to Sarcocystis neurona.

    Science.gov (United States)

    Rossano, M G; Mansfield, L S; Kaneene, J B; Murphy, A J; Brown, C M; Schott, H C; Fox, J C

    2000-01-01

    Equine protozoal myeloencephalitis (EPM) is a neurological disease of horses and ponies caused by the apicomplexan protozoan parasite Sarcocystis neurona. The purposes of this study were to develop the most stringent criteria possible for a positive test result, to estimate the sensitivity and specificity of the EPM Western blot antibody test, and to assess the ability of bovine antibodies to Sarcocystis cruzi to act as a blocking agent to minimize false-positive results in the western blot test for S. neurona. Sarcocystis neurona merozoites harvested from equine dermal cell culture were heat denatured, and the proteins were separated by sodium dodecyl sulfate-polyacrylamide gel electrophoresis in a 12-20% linear gradient gel. Separated proteins were electrophoretically transferred to polyvinylidene fluoride membranes and blocked in 1% bovine serum albumin and 0.5% Tween-Tris-buffered saline. Serum samples from 6 horses with S. neurona infections (confirmed by culture from neural tissue) and 57 horses without infections (horses from the Eastern Hemisphere, where S. neurona does not exist) were tested by Western blot. Horses from both groups had reactivity to the 62-, 30-, 16-, 13-, 11-, 10.5-, and 10-kD bands. Testing was repeated with another step. Blots were treated with bovine S. cruzi antibodies prior to loading the equine samples. After this modification of the Western blot test, positive infection status was significantly associated with reactivity to the 30- and 16-kD bands (Pblot had a sample sensitivity of 100% and sample specificity of 98%. It is concluded that the specificity of the Western blot test is improved by blocking proteins not specific to S. neurona and using reactivity to the 30- and 16-kD bands as the criterion for a positive test.

  17. Radioimmunoassay test system for detection of anti-insulin antibodies

    International Nuclear Information System (INIS)

    Dudko, N.V.; Piven', N.V.; Ibragimova, G.V.; Kasatkin, Yu.N.

    1995-01-01

    A radiodiagnostic test system has been developed and commercial kit for radioimmunoassay of anti-insulin antibodies in human blood serum created. Clinical trials of the kit in patients (150 diabetics with types 1 and 2 condition) and normal subjects (n=100) demonstrated the possibility of using this kit for the detection of preclinical forms of diabetes and for distinguishing groups at risk of diabetes among children and adults, for the detection of insulin resistance, for the differential diagnosis of diabetes, and for monitoring the efficacy of insulin therapy. 9 refs.; 1 tab

  18. Enzyme-linked immunosorbent Assay for detecting of antibody to canine distemper virus

    Directory of Open Access Journals (Sweden)

    Sudarisman

    2006-03-01

    Full Text Available Serum neutralisation test (SNT has been established for evaluating canine distemper vaccination, but until now SNT was rarely used due to the need for continuous tissue culture facilities and requires 3 days to perform. For detecting antibody to canine distemper virus, an enzyme-linked immunosorbent assay (ELISA is relatively simple and rapid seroassay. ELISA for canine immunoglobulin (Ig G antibodies to canine distemper virus (CDV was developed by using Onderstepoort strain of canine distemper virus as coating antigen. Rabbit anti canine IgG labelled with horse radish peroxidase was used as the conjugate, while phenylenediamine dihydrochloride (OPD was used as the substrate. The ELISA results were then compared with the results of the SNT, using the sera of 312 random-source dogs from West Java. The two test-results had a high degree of correlation. Very few discrepancies occurred and most of these were at the lower limits of each test. When the sera were tested at 1 : 100 dilutions, there was a 95.5% agreement between the ELISA and SNT. Their sensitivity and spesificity were 83.9 and 98.4%. Titrated SNT and ELISA also were performed on sera from 7 dogs whose lifetime medical histories were known. The antibodies were inclining up after two months of post vaccination, where the titre was not in zero/lower position at the day of vaccination. However, antibody zero or low position were found at 28 days post vaccination. All of the results indicated that ELISA can be used for evaluating antibody to canine distemper virus response, replacing the SNT.

  19. A Portable Kit for Rapid Diagnosis of Infectious Diseases under Field Conditions

    Science.gov (United States)

    1980-08-14

    INFECTIONS SHIGELLA TYPHOID FEVER STREPTOCOCCUS An example of a public health application for rapid diagnosis using the COAG test is provided by studies...than in infections in Fig. Principles of gel diffusion (GD) and of counter- monkeys with human parasites (BID%%IAL et al. 1973, immunoelectrophoresis...the cerebrospinal fluid and immunofluorescence tests for detection of malaria te ai preient ith croup inal fuidan antibodies in Aotus monkeys

  20. A two-site immunoradiometric assay for human pregnancy-associated plasma protein A (PAPP-A) using monoclonal antibodies

    International Nuclear Information System (INIS)

    Mowles, E.A.; Pinto-Furtado, L.G.; Bolton, A.E.

    1986-01-01

    A rapid, sensitive immunoradiometric assay has been developed for human pregnancy-associated plasma protein A (PAPP-A) using a purified mouse monoclonal antibody as the tracer and a rabbit polyclonal antibody to this protein in the solid-phase antibody preparation. The assay showed no measurable cross-reaction (< 0.1%) against a range of purified human placental proteins, and a good correlation with a previously described radioimmunoassay procedure when tested on samples taken throughout normal human pregnancies. No PAPP-A-like immunological activity could be detected in sera from non-pregnant women, confirming the absence of this protein from the circulation outside pregnancy. (Auth.)

  1. Estimating the true accuracy of diagnostic tests for dengue infection using bayesian latent class models.

    Directory of Open Access Journals (Sweden)

    Wirichada Pan-ngum

    Full Text Available Accuracy of rapid diagnostic tests for dengue infection has been repeatedly estimated by comparing those tests with reference assays. We hypothesized that those estimates might be inaccurate if the accuracy of the reference assays is not perfect. Here, we investigated this using statistical modeling.Data from a cohort study of 549 patients suspected of dengue infection presenting at Colombo North Teaching Hospital, Ragama, Sri Lanka, that described the application of our reference assay (a combination of Dengue IgM antibody capture ELISA and IgG antibody capture ELISA and of three rapid diagnostic tests (Panbio NS1 antigen, IgM antibody and IgG antibody rapid immunochromatographic cassette tests were re-evaluated using bayesian latent class models (LCMs. The estimated sensitivity and specificity of the reference assay were 62.0% and 99.6%, respectively. Prevalence of dengue infection (24.3%, and sensitivities and specificities of the Panbio NS1 (45.9% and 97.9%, IgM (54.5% and 95.5% and IgG (62.1% and 84.5% estimated by bayesian LCMs were significantly different from those estimated by assuming that the reference assay was perfect. Sensitivity, specificity, PPV and NPV for a combination of NS1, IgM and IgG cassette tests on admission samples were 87.0%, 82.8%, 62.0% and 95.2%, respectively.Our reference assay is an imperfect gold standard. In our setting, the combination of NS1, IgM and IgG rapid diagnostic tests could be used on admission to rule out dengue infection with a high level of accuracy (NPV 95.2%. Further evaluation of rapid diagnostic tests for dengue infection should include the use of appropriate statistical models.

  2. Effect of antibody charge and concentration on deposition of antibody to glomerular basement membrane

    International Nuclear Information System (INIS)

    Madaio, M.P.; Salant, D.J.; Adler, S.; Darby, C.; Couser, W.G.

    1984-01-01

    Fixed anionic sites within the glomerular capillary wall influence the permeation of serum proteins, the localization of various antigens, and the deposition of antibody in the subepithelial space. In anti-GBM nephritis antibody deposition occurs very rapidly to antigenic sites located relatively proximal in the glomerular capillary wall. The authors examined the influence of the glomerular charge barrier on anti-GBM antibody deposition by comparing the rate of deposition of antibodies with cationic and anionic isoelectric points. Purified sheep anti-rat GBM IgG was isolated from acid eluates of kidneys obtained 24 hr after rats were injected with sheep antiserum to rat GBM. Anti-GBM IgG was separated into cationic (pI 6.4-8.5) and anionic (pI 4.2-6.8) fractions, which were radiolabelled with 131 I and 125 I, respectively, shown to have equal antibody contents measured by in vitro binding to normal glomeruli, mixed in equal amounts, and injected in incremental doses to ten rats. At 1 hr the glomerular antibody binding of each fraction was directly related to the blood level (r . 0.95, r . 0.97) and delivery of antibody (r . 0.98, r . 0.98). Glomerular binding of cationic antibody was four times greater than anionic antibody over the entire range of deliveries studied (P less than 0.001). The authors conclude that glomerular deposition of anti-GBM antibody is directly related to blood concentration and delivery of antibody. Furthermore, the deposition of cationic antibodies to GBM antigens was significantly greater than the deposition of anionic antibodies

  3. Red Blood Cell Antibody Screen: MedlinePlus Lab Test Information

    Science.gov (United States)

    ... medlineplus.gov/labtests/redbloodcellantibodyscreen.html Red Blood Cell Antibody Screen To use the sharing features on this page, please enable JavaScript. What is an RBC Antibody Screen? An RBC (red blood cell) antibody screen ...

  4. Comparison of Rapid Malaria Test and Laboratory Microscopy ...

    African Journals Online (AJOL)

    Michael Horsfall

    ABSTRACT: Blood samples collected from 272 volunteers in two communities of Bayelsa State in the Niger. Delta area were investigated for falciparum malaria parasite using the rapid test based on the detection of soluble antigen and laboratory microscopy test. The data showed that out of the 272 samples collected, ...

  5. Autoantibodies to the Rpp25 component of the Th/To complex are the most common antibodies in patients with systemic sclerosis without antibodies detectable by widely available commercial tests.

    Science.gov (United States)

    Mahler, Michael; Satoh, Minoru; Hudson, Marie; Baron, Murray; Chan, Jason Y F; Chan, Edward K L; Wick, James; Fritzler, Marvin J

    2014-07-01

    Antinuclear antibodies (ANA) occur in up to 95% of patients with systemic sclerosis (SSc). In most, SSc-associated antibodies are detected (i.e., centromere, topoisomerase I, RNA polymerase III, PM/Scl, Ro52/TRIM21, and U1RNP). Ribonuclease P protein subunit p25, (Rpp25) is an autoantigenic component of the Th/To complex. The contribution of anti-Th/To and anti-Rpp25 antibodies to ANA positivity in patients with SSc remains unknown. Sera from 873 patients with SSc were tested for ANA, and SSc-associated antibodies were measured. Samples without antibodies to extractable nuclear antigens (ENA; n = 53, ANA+/ENA-), were analyzed by immunoprecipitation (IP) and metabolically labeled proteins and for anti-Rpp25 antibodies (n = 50) by a chemiluminescent immunoassay (CLIA) and Rpp25 ELISA. Anti-Th/To antibodies occurred in 19/53 (36%), as determined by IP, and were the most common autoantibody in ANA+/ENA- SSc. Of those samples, 50/53 were available for additional testing by CLIA and ELISA. Anti-Rpp25 antibodies were detected in 12 (24% CLIA) or 10 (20% ELISA) of 50 patients. Receiver-operating characteristic curve analysis showed similar discrimination between Th/To IP-positive (n = 19) and -negative samples (n = 31) by CLIA and ELISA (area under the curve 0.90 vs 0.87; p = 0.6691). The positive percent agreement between IP and CLIA or ELISA was 12/19 (63.2%, 95% CI 38.4-83.7%) or 10/19 (52.6%, 95% CI 73.3-94.2%), respectively. Negative percent agreement was 100% for both assays. Autoantibodies to the Th/To autoantigen are important in patients with SSc who have been considered negative for SSc-specific or SSc-associated antibodies by widely available commercial assays. Rpp25 can be considered a major target of anti-Th/To antibodies. Assays detecting anti-Th/To and anti-Rpp25 antibodies may be important in SSc.

  6. Study on the technical parameters of two different systems of RIA performed with solid-phase antibody test tubes prepared with magnetic microparticle covalence conjagation or conventional physical absorption

    International Nuclear Information System (INIS)

    Chen Zhiqiang; Wang Chengmin; Tang Baojun

    2007-01-01

    Objective: To investigate a new method of preparation of solid-phase antibody with flurorescein isothioeynate (FITC)-anti FITC magnetic nanoparticles system (for FT 3 and TSH). Methods: FT 3 and TSH monoclonal antibody IgC was la- belied with FITC. Anti-FITC magnetic mieroparticles was prepared and conjugated with the FITC labelled antibody to form the solid - phase coated test tube for RIA. Solid-phase test tube prepared with the conventional physical absorption method was also used for RIA and the technical parameters of the two systems were compared. Results: For FT 3 , the sensitivity was 0.18pmol/L with the new method and 0.43pmol/L with the conventional method. Other parameters were; intra-CV, 8.96% vs 16.26%; inter-CV, 15.25% vs 18.83%, correlation with PR method r=0.9825 vs r=0.9102. For TSH, sensitivity was 0.061 μIU/ml vs 0.04 μ IU/ml, intra- CV, 7.6% vs 6.92%, inter-CV, 8.55% vs 14.23%, correlation between the new and conventional method, r=0. 9987. TSH RIA was especially rapid with the new technic: 79 min vs 190 min. Conclusion: For FT 3 and TSH RIA, the new method takes much less time with increased homogeniety. (authors)

  7. Rapid detection of serum antibody by dual-path platform VetTB assay in white-tailed deer infected with Mycobacterium bovis.

    Science.gov (United States)

    Lyashchenko, Konstantin P; Greenwald, Rena; Esfandiari, Javan; O'Brien, Daniel J; Schmitt, Stephen M; Palmer, Mitchell V; Waters, W Ray

    2013-06-01

    Bovine tuberculosis (TB) in cervids remains a significant problem affecting farmed herds and wild populations. Traditional skin testing has serious limitations in certain species, whereas emerging serological assays showed promising diagnostic performance. The recently developed immunochromatographic dual-path platform (DPP) VetTB assay has two antigen bands, T1 (MPB83 protein) and T2 (CFP10/ESAT-6 fusion protein), for antibody detection. We evaluated the diagnostic accuracy of this test by using serum samples collected from groups of white-tailed deer experimentally inoculated with Mycobacterium bovis, M. avium subsp. paratuberculosis, or M. bovis BCG Pasteur. In addition, we used serum samples from farmed white-tailed deer in herds with no history of TB, as well as from free-ranging white-tailed deer culled during field surveillance studies performed in Michigan known to have bovine TB in the wild deer population. The DPP VetTB assay detected antibody responses in 58.1% of experimentally infected animals within 8 to 16 weeks postinoculation and in 71.9% of naturally infected deer, resulting in an estimated test sensitivity of 65.1% and a specificity of 97.8%. The higher seroreactivity found in deer with naturally acquired M. bovis infection was associated with an increased frequency of antibody responses to the ESAT-6 and CFP10 proteins, resulting in a greater contribution of these antigens, in addition to MPB83, to the detection of seropositive animals, compared with experimental M. bovis infection. Deer experimentally inoculated with either M. avium subsp. paratuberculosis or M. bovis BCG Pasteur did not produce cross-reactive antibodies that could be detected by the DPP VetTB assay. The present findings demonstrate the relatively high diagnostic accuracy of the DPP VetTB test for white-tailed deer, especially in the detection of naturally infected animals.

  8. Dual antibody therapy to harness the innate anti-tumor immune response to enhance antibody targeting of tumors.

    Science.gov (United States)

    Chester, Cariad; Marabelle, Aurelien; Houot, Roch; Kohrt, Holbrook E

    2015-04-01

    Cancer immunotherapy is a rapidly evolving field that offers a novel paradigm for cancer treatment: therapies focus on enhancing the immune system's innate and adaptive anti-tumor response. Early immunotherapeutics have achieved impressive clinical outcomes and monoclonal antibodies are now integral to therapeutic strategies in a variety of cancers. However, only recently have antibodies targeting innate immune cells entered clinical development. Innate immune effector cells play important roles in generating and maintaining antitumor immunity. Antibody-dependent cell-mediated cytotoxicity (ADCC) and antibody-dependent cellular phagocytosis (ADCP) are important innate immune mechanisms for tumor eradication. These cytolytic processes are initiated by the detection of a tumor-targeting antibody and can be augmented by activating co-stimulatory pathways or blocking inhibitory signals on innate immune cells. The combination of FDA-approved monoclonal antibodies with innate effector-targeting antibodies has demonstrated potent preclinical therapeutic synergy and early-phase combinatorial clinical trials are ongoing. Copyright © 2015 Elsevier Ltd. All rights reserved.

  9. Anti-Trypanosoma cruzi antibody detection in eastern Andalusia (Spain).

    Science.gov (United States)

    Marín, Clotilde; Concha-Valdez, Fanny; Cañas, Rocío; Gutiérrez-Sánchez, Ramón; Sánchez-Moreno, Manuel

    2014-03-01

    Chagas disease caused by the protozoan haemoflagellate Trypanosoma cruzi is no longer found exclusively in Latin America; the disease is occurring in Europe, and Spain is the country with the highest prevalence. Our aim was to detect anti-T. cruzi antibodies in blood donors from southeast Spain, and we performed eight serological diagnostic assays on each of 550 blood samples collected in March-June 2010. Two in-house ELISA methods were used to test against a parasite lysate (ELISA-H) and the semi-purified superoxide dismutase excreted by T. cruzi (ELISA-SODe); we also used the Western blot technique against the same antigen (WB-SODe), indirect immunofluorescence (IFA) and four commercial tests. The serological test results showed a range of seroprevalence values, the lowest being 1.1%, determined by IFA and two commercial tests (Ab rapid and Chagascreen); other values were: 1.3% (commercial ELISA [Chagas ELISA IgG+IgM]); 2.1% (immunochromatographic test [Stick Chagas]); 2.7% (ELISA-H); 4.0% (WB-SODe); and 4.2%, the highest value (ELISA-SODe). The excellent specificity of SODe antigen for the detection of antibodies to T. cruzi in donors lead us to affirm that the serological test performed with this biomarker could provide a useful screening and confirmatory test method for cases of Chagas disease.

  10. An indirect antibody assay using haptenated antigen and 125I-labelled anti-hapten antibody

    International Nuclear Information System (INIS)

    Aalberse, R.C.; Amsterdam Univ.

    1978-01-01

    Hapten (trinitrophenyl) was coupled to antigen (ovalbumin). The haptenated antigen was bound by anti-ovalbumin antibody and binding was quantitated with 125 I-labelled anti-hapten antibodies. Thus, with a single radioactive reagent, antibodies against a variety of antigens can be detected while the problems inherent in a labelled antiglobulin binding test are avoided. In the ovalbumin system, the haptenated antigen binding test proved to be approximately 20 times as sensitive as the iodinated ovalbumin binding test

  11. Seroprevalence of Mycoplasma gallisepticum antibody by ELISA and serum plate agglutination test of laying chicken

    Directory of Open Access Journals (Sweden)

    Md. Zulfekar Ali

    2015-01-01

    Full Text Available Aim: Mycoplasma gallisepticum (MG is important avian pathogen responsible for chronic respiratory disease of chicken and turkeys, which result in large economic loss for the poultry industry. The objectives of this study were determination of seroprevalence of MG antibody of commercial layer chicken at laying period in selected areas of Bangladesh. Materials and Methods: A total of 563 blood samples were collected randomly from selected commercial layer chickens at laying period during the period from July to December, 2013. Indirect enzyme linked immunosorbent assay (iELISA and serum plate agglutination (SPA test were performed to detect the presence of antibodies against MG. Results: Of 563 samples, 64.47% and 56.13% showed an overall prevalence of MG antibodies in iELISA and SPA test respectively. Prevalence of MG was recorded the highest (69.63% at 50-55 weeks of age compared with lowest (53.26% at 56-61 weeks of age (p<0.05. Significant (p<0.05 effect of breed were observed in the seroprevalence of MG infection in layer birds in the present study. The overall, 68.77%, 63.74% and 59.37% prevalence were found respectively in sonali, ISA Brown and White leg horn. The prevalence of MG antibodies was the highest (70.13% in December followed by November (68%, October (65.67%, August (63.46%, September (58.54% and July (51.78% month. The seroprevalence of MG antibodies was higher (69.63% in most of the large flocks and lower (56.82% in small flocks. Conclusion: Therefore, might be suggested that the commercial layer farms should be routinely checked to monitor MG infection and the reactor birds should be culled since MG organism has the potential to transmit vertically. The correlation between MG antibody in month and flock size was not significant (p=0.359 and p=0.868, respectively.

  12. Rapid Immuno-Chromatographic Assay for the Detection of Antibodies to HIV Compare with Elisa among Voluntary and Replacement Blood Donor of Mymensingh Medical College Hospital.

    Science.gov (United States)

    Chakrabarty, P; Rudra, S; Hossain, M A; Begum, S A; Mirza, T T; Rudra, M

    2015-04-01

    Suitable algorithms based on a combination of two or more simple rapid HIV assays have been shown to have a diagnostic accuracy comparable to double enzyme-linked immunosorbent assay (ELISA) or double ELISA with Western Blot strategies. The aims of this study were to evaluate the performance of five simple rapid HIV assays using whole blood samples from voluntary and replacement blood donors & HIV-infected patients (positive samples from BSMMU, Dhaka). Five rapid HIV assays: Determine™ HIV-1/2 (Inverness Medical), SD Bioline HIV 1/2 3.0 (Standard Diagnostics Inc.), First Response HIV Card 1-2.0 (PMC Medical India Pvt Ltd.), HIV1/2 Stat-Pak Dipstick (Chembio Diagnostic System, Inc) and Uni-Gold™ HIV-1/2 (Biotech) were evaluated between 1st February to 30th June, 2013 using 400 whole blood samples from voluntary and replacement blood donors. All samples that were reactive on all or any of the five rapid assays and 10% of non-reactive samples were tested on a confirmatory Inno-Lia HIV I/II immunoblot assay (Immunogenetics). Only 01 sample including ten positive samples from BSMMU were confirmed HIV-1 antibody positive, while 399 were HIV negative. The sensitivity at initial testing of Determine, SD Bioline and Uni-Gold™ was 100% (95% CI; 99.1-100) while First Response and Stat-Pak had sensitivity of 99.5% (95% CI; 98.2-99.9) and 97.7% (95% CI; 95.7-98.9) respectively, which increased to 100% (95% CI; 99.1-100) on repeat testing. The initial specificity of the Uni-Gold™ assay was 100% (95% CI; 99.6-100) while specificities were 99.6% (95% CI; 99-99.9), 99.4% (95% CI; 98.8-99.7), 99.6% (95% CI; 99-99.9) and 99.8% (95% CI; 99.3-99.9) for Determine, SD Bioline, First Response and Stat-Pak assays, respectively. There was no any sample which was concordantly false positive in Uni-Gold™, Determine and SD Bioline assays. An alternative confirmatory HIV testing strategy based on initial testing on either SD Bioline or Determine assays followed by testing of reactive

  13. A comparison of test statistics for the recovery of rapid growth-based enumeration tests

    NARCIS (Netherlands)

    van den Heuvel, Edwin R.; IJzerman-Boon, Pieta C.

    This paper considers five test statistics for comparing the recovery of a rapid growth-based enumeration test with respect to the compendial microbiological method using a specific nonserial dilution experiment. The finite sample distributions of these test statistics are unknown, because they are

  14. Engineered Antibodies for Monitoring of Polynuclear Aromatic Hydrocarbons

    Energy Technology Data Exchange (ETDEWEB)

    Alexander E. Karu Ph.D; Victoria A. Roberts Ph.D.; Qing X. Li, Ph.D.

    2002-01-17

    This project was undertaken to fill needs in ODE's human and ecosystem health effects research, site remediation, rapid emergency response, and regulatory compliance monitoring programs. Doe has greatly stimulated development and validation of antibody-based, rapid, field-portable detection systems for small hazardous compounds. These range from simple dipsticks, microplate enzyme-linked immunosorbent assays (ELISAs), and hand-held colorimeters, to ultrasensitive microfluidic reactors, fiber-optic sensors and microarrays that can identify multiple analytes from patterns of cross-reactivity. Unfortunately, the technology to produce antibodies with the most desirable properties did not keep pace. Lack of antibodies remains a limiting factor in production and practical use of such devices. The goals of our project were to determine the chemical and structural bases for the antibody-analyte binding interactions using advanced computational chemistry, and to use this information to create useful new binding properties through in vitro genetic engineering and combinatorial library methods.

  15. Antinuclear antibody panel

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003535.htm Antinuclear antibody panel To use the sharing features on this page, please enable JavaScript. The antinuclear antibody panel is a blood test that looks at ...

  16. Antithyroglobulin Antibodies and Antimicrosomal Antibodies in Various Thyroid Diseases

    International Nuclear Information System (INIS)

    Lee, Gwon Jun; Hong, Key Sak; Choi, Kang Won; Lee, Kyu; Koh, Chang Soon; Lee, Mun Ho; Park, Sung Hoe; Chi, Je Geun; Lee, Sang Kook

    1979-01-01

    The authors investigated the incidence of antithyroglobulin antibodies and antibodies and antimicrosomal antibodies measured by tanned red cell hemagglutination method in subjects suffering from various thyroid disorders. 1) In 15 normal patients, neither suffering from any thyroid diseases nor from any other autoimmune disorders, the antithyroglobulin antibodies were all negative, but the antimicrosomal antibody was positive only in one patient (6.7%). 2) The antithyroglobulin antibodies were positive in 31.5% (34 patients) of 108 patients with various thyroid diseases, and the antimicrosomal antibodies were positive in 37.0% (40 patients). 3) of the 25 patients with Graves' diseases, 7 patients (28.0%) showed positive for the antithyroglobulin antibodies, and 9 (36.0%) for the antimicrosomal antibodies. There was no definite differences in clinical and thyroid functions between the groups with positive and negative results. 4) Both antibodies were positive in 16 (88.9%) and 17 (94.4%) patients respectively among 18 patients with Hashimoto's thyroiditis, all of them were diagnosed histologically. 5) Three out of 33 patients with thyroid adenoma showed positive antibodies, and 3 of 16 patients with thyroid carcinoma revealed positive antibodies. 6) TRCH antibodies demonstrated negative results in 2 patients with subacute thyroiditis, but positive in one patient with idiopathic primary myxedema. 7) The number of patients with high titers(>l:802) was 16 for antithyroglobulin antibody, and 62.5% (10 patients) of which was Hashimoto's thyroiditis. Thirteen (65.0) of 20 patients with high titers (>l:802) for antimicrosomal antibody was Hashimoto's thyroiditis. TRCH test is a simple, sensitive method, and has high reliability and reproducibility. The incidences and titers of antithyroglobulin antibody and antimicrosomal antibody are especially high in Hashimoto's thyroiditis.

  17. Antibody profiling sensitivity through increased reporter antibody layering

    Science.gov (United States)

    Apel, William A; Thompson, Vicki S

    2013-02-26

    A method for analyzing a biological sample by antibody profiling for identifying forensic samples or for detecting the presence of an analyte. In an embodiment of the invention, the analyte is a drug, such as marijuana, Cocaine (crystalline tropane alkaloid), methamphetamine, methyltestosterone, or mesterolone. The method comprises attaching antigens to a surface of a solid support in a preselected pattern to form an array wherein locations of the antigens are known; contacting the array with the biological sample such that a portion of antibodies in the sample reacts with and binds to the antigens in the array to form immune complexes; washing away antibodies that do form immune complexes; and detecting the immune complexes, to form an antibody profile. Forensic samples are identified by comparing a sample from an unknown source with a sample from a known source. Further, an assay, such as a test for illegal drug use, can be coupled to a test for identity such that the results of the assay can be positively correlated to the subject's identity.

  18. Antibody profiling sensitivity through increased reporter antibody layering

    Energy Technology Data Exchange (ETDEWEB)

    Apel, William A.; Thompson, Vicki S.

    2017-03-28

    A method for analyzing a biological sample by antibody profiling for identifying forensic samples or for detecting the presence of an analyte. In an embodiment of the invention, the analyte is a drug, such as marijuana, Cocaine (crystalline tropane alkaloid), methamphetamine, methyltestosterone, or mesterolone. The method comprises attaching antigens to a surface of a solid support in a preselected pattern to form an array wherein locations of the antigens are known; contacting the array with the biological sample such that a portion of antibodies in the sample reacts with and binds to the antigens in the array to form immune complexes; washing away antibodies that do form immune complexes; and detecting the immune complexes, to form an antibody profile. Forensic samples are identified by comparing a sample from an unknown source with a sample from a known source. Further, an assay, such as a test for illegal drug use, can be coupled to a test for identity such that the results of the assay can be positively correlated to the subject's identity.

  19. Antibody profiling sensitivity through increased reporter antibody layering

    Energy Technology Data Exchange (ETDEWEB)

    Apel, William A.; Thompson, Vicki S.

    2013-02-26

    A method for analyzing a biological sample by antibody profiling for identifying forensic samples or for detecting the presence of an analyte. In an embodiment of the invention, the analyte is a drug, such as marijuana, Cocaine (crystalline tropane alkaloid), methamphetamine, methyltestosterone, or mesterolone. The method comprises attaching antigens to a surface of a solid support in a preselected pattern to form an array wherein locations of the antigens are known; contacting the array with the biological sample such that a portion of antibodies in the sample reacts with and binds to the antigens in the array to form immune complexes; washing away antibodies that do form immune complexes; and detecting the immune complexes, to form an antibody profile. Forensic samples are identified by comparing a sample from an unknown source with a sample from a known source. Further, an assay, such as a test for illegal drug use, can be coupled to a test for identity such that the results of the assay can be positively correlated to the subject's identity.

  20. Antibody profiling sensitivity through increased reporter antibody layering

    Energy Technology Data Exchange (ETDEWEB)

    Apel, William A.; Thompson, Vicki S

    2010-04-13

    A method for analyzing a biological sample by antibody profiling for identifying forensic samples or for detecting the presence of an analyte. In an embodiment of the invention, the analyte is a drug, such as marijuana, Cocaine (crystalline tropane alkaloid), methamphetamine, methyltestosterone, or mesterolone. The method comprises attaching antigens to a surface of a solid support in a preselected pattern to form an array wherein locations of the antigens are known; contacting the array with the biological sample such that a portion of antibodies in the sample reacts with and binds to the antigens in the array to form immune complexes; washing away antibodies that do form immune complexes; and detecting the immune complexes, to form an antibody profile. Forensic samples are identified by comparing a sample from an unknown source with a sample from a known source. Further, an assay, such as a test for illegal drug use, can be coupled to a test for identity such that the results of the assay can be positively correlated to the subject's identity.

  1. Detection of anti neutrophil antibodies by radio-iodinated protein A binding test

    International Nuclear Information System (INIS)

    Cartron, J.; Muller, J.Y.; Tchernia, G.; Paule, B.; Varet, B.

    1983-01-01

    The granulocyte associated IgG in normal and neutropenic subjects has been determined by a direct quantitative assay using radiolabeled staphylococcal protein A. This assay allows to postulate an immunological mechanism to explain the neutropenia in 19 cases of neutropenias associated with malfunctions of the immune system and in 4 cases of idiopathic neutropenias. Discussed in this report is the possible interaction of immune complexes bound in vivo to the granulocytes. By an immunofluorescence test, it has been possible to detect IgG or IgM antibodies in only 52% of patients with a positive direct assay. The determination of granulocyte-associated IgG is therefore a better indicator for defining an auto-immune neutropenia than the detection of free antibodies in the sera [fr

  2. EU-approved rapid tests might underestimate bovine spongiform encephalopathy infection in goats

    NARCIS (Netherlands)

    Meloni, Daniela; Bozzetta, Elena; Langeveld, Jan P.M.; Groschup, Martin H.; Goldmann, Wilfred; Andrèoletti, Olivier; Lantier, Isabelle; Keulen, Van Lucien; Bossers, Alex; Pitardi, Danilo; Nonno, Romolo; Sklaviadis, Theodoros; Ingravalle, Francesco; Peletto, Simone; Colussi, Silvia; Acutis, Pier Luigi

    2017-01-01

    We report the diagnostic sensitivity of 3 EU-approved rapid tests (ELISAs; 1 from IDEXX and 2 from Bio-Rad) for the detection of transmissible spongiform encephalopathy diseases in goats. Ninety-eight goat brainstem samples were tested. All the rapid tests had 100% specificity and ≥80% sensitivity,

  3. Characterization of antibody response in neuroinvasive infection caused by Toscana virus.

    Science.gov (United States)

    Pierro, A; Ficarelli, S; Ayhan, N; Morini, S; Raumer, L; Bartoletti, M; Mastroianni, A; Prati, F; Schivazappa, S; Cenni, P; Vocale, C; Rossini, G; Gaibani, P; Sambri, V; Landini, M P; Lewis, R E; Charrel, R N; Varani, S

    2017-11-01

    Among sandfly-borne pathogens, Toscana virus (TOSV) is a prominent cause of summer meningitis in Mediterranean Europe. Here, we assessed the kinetics of anti-TOSV antibodies over time in 41 patients diagnosed with TOSV meningitis or meningoencephalitis in northeastern Italy. Acute and follow-up serum samples were collected up to 20 months after diagnosis of TOSV infection and tested for the presence of specific antibody using immunoenzymatic and indirect immunofluorescence assays. In addition, maturation of anti-TOSV IgG over time was evaluated as well as production of neutralizing antibodies. Specific IgM and IgG response was present at diagnosis in 100% of patients; TOSV-specific IgM and IgG were detected in patients' sera up to 6 and 20 months after diagnosis, respectively. The avidity index (AI) increased over the first month after infection in 100% of patients and most cases exceeded 60% by Day 30 post infection. The AI subsequently plateaued then declined at 20 months after diagnosis. Finally, neutralization assay to TOSV was performed in 217 sera collected from 41 patients; 69.6% of tested samples resulted in reactive and moderate levels of neutralizing antibodies observed during all phases of infection despite high titres of total anti-TOSV IgG. Specific antibody response develops rapidly and is long-lasting for neuroinvasive TOSV infection. Serodiagnosis of neuroinvasive TOSV requires simultaneous detection of specific IgM and IgG. Moderate levels of neutralizing antibodies were maintained over the study period, while the protective role of antibodies lacking neutralizing activity is unclear and requires further evaluation. Copyright © 2017 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  4. Rapid lysostaphin test to differentiate Staphylococcus and Micrococcus species.

    Science.gov (United States)

    Geary, C; Stevens, M

    1986-01-01

    A rapid, simple lysostaphin lysis susceptibility test to differentiate the genera Staphylococcus and Micrococcus was evaluated. Of 181 strains from culture collections, 95 of 95 Staphylococcus strains were lysed, and 79 of 79 Micrococcus strains were not lysed. The seven Planococcus strains were resistant. Clinical isolates (890) were tested with lysostaphin and for the ability to produce acid from glycerol in the presence of erythromycin. Overall agreement between the methods was 99.2%. All clinical Micrococcus strains (43) were resistant to lysostaphin, and all clinical Staphylococcus strains (847) were susceptible. Seven of the Staphylococcus strains did not produce acid from glycerol in the presence of erythromycin. This lysostaphin test provides results in 2 h. It is easier to perform than previously described lysostaphin lysis methods. It is also more rapid and accurate than the glycerol-erythromycin test. PMID:3519667

  5. Cost-effectiveness of Chlamydia antibody tests in subfertile women.

    Science.gov (United States)

    Fiddelers, A A A; Land, J A; Voss, G; Kessels, A G H; Severens, J L

    2005-02-01

    For the evaluation of tubal function, Chlamydia antibody testing (CAT) has been introduced as a screening test. We compared six CAT screening strategies (five CAT tests and one combination of tests), with respect to their cost-effectiveness, by using IVF pregnancy rate as outcome measure. A decision analytic model was developed based on a source population of 1715 subfertile women. The model incorporates hysterosalpingography (HSG), laparoscopy and IVF. To calculate IVF pregnancy rates, costs, effects, cost-effectiveness and incremental costs per effect of the six different CAT screening strategies were determined. pELISA Medac turned out to be the most cost-effective CAT screening strategy (15 075 per IVF pregnancy), followed by MIF Anilabsystems (15 108). A combination of tests (pELISA Medac and MIF Anilabsystems; 15 127) did not improve the cost-effectiveness of the single strategies. Sensitivity analyses showed that the results are robust for changes in the baseline values of the model parameters. Only small differences were found between the screening strategies regarding the cost-effectiveness, although pELISA Medac was the most cost-effective strategy. Before introducing a particular CAT test into clinical practice, one should consider the effects and consequences of the entire screening strategy, instead of only the diagnostic accuracy of the test used.

  6. Antithyroglobulin Antibodies and Antimicrosomal Antibodies in Various Thyroid Diseases

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Gwon Jun; Hong, Key Sak; Choi, Kang Won; Lee, Kyu; Koh, Chang Soon; Lee, Mun Ho; Park, Sung Hoe; Chi, Je Geun; Lee, Sang Kook [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1979-03-15

    The authors investigated the incidence of antithyroglobulin antibodies and antibodies and antimicrosomal antibodies measured by tanned red cell hemagglutination method in subjects suffering from various thyroid disorders. 1) In 15 normal patients, neither suffering from any thyroid diseases nor from any other autoimmune disorders, the antithyroglobulin antibodies were all negative, but the antimicrosomal antibody was positive only in one patient (6.7%). 2) The antithyroglobulin antibodies were positive in 31.5% (34 patients) of 108 patients with various thyroid diseases, and the antimicrosomal antibodies were positive in 37.0% (40 patients). 3) of the 25 patients with Graves' diseases, 7 patients (28.0%) showed positive for the antithyroglobulin antibodies, and 9 (36.0%) for the antimicrosomal antibodies. There was no definite differences in clinical and thyroid functions between the groups with positive and negative results. 4) Both antibodies were positive in 16 (88.9%) and 17 (94.4%) patients respectively among 18 patients with Hashimoto's thyroiditis, all of them were diagnosed histologically. 5) Three out of 33 patients with thyroid adenoma showed positive antibodies, and 3 of 16 patients with thyroid carcinoma revealed positive antibodies. 6) TRCH antibodies demonstrated negative results in 2 patients with subacute thyroiditis, but positive in one patient with idiopathic primary myxedema. 7) The number of patients with high titers(>l:802) was 16 for antithyroglobulin antibody, and 62.5% (10 patients) of which was Hashimoto's thyroiditis. Thirteen (65.0) of 20 patients with high titers (>l:802) for antimicrosomal antibody was Hashimoto's thyroiditis. TRCH test is a simple, sensitive method, and has high reliability and reproducibility. The incidences and titers of antithyroglobulin antibody and antimicrosomal antibody are especially high in Hashimoto's thyroiditis.

  7. Evaluation of rapid radiometric method for drug susceptibility testing of Mycobacterium tuberculosis

    International Nuclear Information System (INIS)

    Siddiqi, S.H.; Libonati, J.P.; Middlebrook, G.

    1981-01-01

    A total of 106 isolates of Mycobacterium tuberculosis were tested for drug susceptibility by the conventional 7H11 plate method and by a new rapid radiometric method using special 7H12 liquid medium with 14 C-labeled substrate. Results obtained by the two methods were compared for rapidity, sensitivity, and specificity of the new test method. There was 98% overall agreement between the results obtained by the two methods. Of a total of 424 drug tests, only 8 drug results did not agree, mostly in the case of streptomycin. This new procedure was found to be rapid, with 87% of the tests results reportable within 4 days and 98% reportable within 5 days as compared to the usual 3 weeks required with the conventional indirect susceptibility test method. The results of this preliminary study indicate that the rapid radiometric method seems to have the potential for routine laboratory use and merits further investigations

  8. Detection of gonococcal infection : pros and cons of a rapid test.

    Science.gov (United States)

    Vickerman, Peter; Peeling, Rosanna W; Watts, Charlotte; Mabey, David

    2005-01-01

    WHO estimates that 62 million cases of gonorrhea occur annually worldwide. Untreated infection can cause serious long-term complications, especially in women. In addition, Neisseria gonorrheae infection can facilitate HIV transmission, and babies born to infected mothers are at risk of ocular infection, which can lead to blindness. Where diagnostic facilities are lacking, gonorrhea can be treated syndromically. However, this inevitably leads to over-treatment, especially in women in whom the syndrome of vaginal discharge may be due not to N. gonorrheae infection but to several other more prevalent conditions. Over-treatment is a major concern because of widespread N. gonorrheae antibiotic resistance. Moreover, a high proportion of gonorrhea cases are asymptomatic and so do not present for syndromic management. Such cases will only be detected by screening tests. The gold standard test for the detection of N. gonorrheae is culture, which has high sensitivity and specificity. However, it requires well trained staff and its performance is affected by specimen transport conditions. Other options include microscopy and tests that detect gonococcal antigen or nucleic acid. Nucleic acid amplification tests (NAATs) have higher sensitivity and can be used on non-invasive samples (urine). However, they can cross-react with other Neisseria species and are expensive, requiring highly trained staff and sophisticated equipment. In settings where patients are asked to return for laboratory results, some infected patients never receive treatment as they fail to return for their test results. This reduction in treatment, and the possible onward transmission of N. gonorrheae during any delay in treatment, means that a rapid test of lower sensitivity may be more effective if it results in patients being treated at the initial visit. Indeed, even with the low sensitivity of currently available rapid tests (50-70%), modeling shows that they can outperform gold standard tests in

  9. [Standardization of the quantitative flow cytometric test with anti-D antibodies for fetomaternal hemorrhage in RhD negative women].

    Science.gov (United States)

    Spychalska, Justyna; Uhrynowska, Małgorzata; Pyl, Hanna; Klimczak-Jajor, Edyta; Kopeć, Izabella; Peciakowska, Małgorzata; Gutowska, Renata; Gawlak, Maciej; Słomska, Sylwia; Dąbkowska, Syiwia; Szczecina, Roman; Dębska, Marzena; Brojer, Ewa

    2015-07-01

    In order to determine the appropriate dose of anti-D immunoglobulin to be administered as a preventive measure against hemolytic disease of the fetus/newborn in the subsequent pregnancy it is necessary to assess the number of fetal red blood cells that infiltrate/penetrate into the maternal circulation as a result of fetomaternal hemorrhage (FMH). One of the quantitative methods of FMH analysis is based on flow cytometry (FACS) which makes use of monoclonal antibodies to RhD antigen (anti-D test). The aim of the study was to further develop the method, evaluate its sensitivity and reproducibility and to compare it with the test based on the detection of fetal hemoglobin (HbF). The FACS study involved 20 RhD negative pregnant women and 80 RhD negative women after delivery. The following monoclonal antibodies were used: BRAD 3 FITC (anti-RhD antigen), CD45 PerCP (anti leukocyte antigen CD45), and anti-HbF PE. The fluorescence intensity of cells incubated with BRAD 3 FITC was demonstrated to depend on the RhD antigen expression, though the anti-D test also detects the weak D variant. The CD45 PerCP antibodies increased the sensitivity of anti-D test since they eliminated the leukocytes which non-specifically bind anti-D from the analysis. The presence of anti-D antibodies in maternal plasma does not affect the quantitative assessment of the fetal RhD positive fetal cells with BRAD 3 FITC. In case of FMH, the results of the anti-D test were similar to those with anti-HbF antibodies. The flow cytometric test with anti-D and anti-CD45 is useful in the assessment of the fetomaternal hemorrhage in RhD negative women. The sensitivity of the test is estimated at 0.05%.

  10. Feasibility of supervised self-testing using an oral fluid-based HIV rapid testing method: a cross-sectional, mixed method study among pregnant women in rural India.

    Science.gov (United States)

    Sarkar, Archana; Mburu, Gitau; Shivkumar, Poonam Varma; Sharma, Pankhuri; Campbell, Fiona; Behera, Jagannath; Dargan, Ritu; Mishra, Surendra Kumar; Mehra, Sunil

    2016-01-01

    HIV self-testing can increase coverage of essential HIV services. This study aimed to establish the acceptability, concordance and feasibility of supervised HIV self-testing among pregnant women in rural India. A cross-sectional, mixed methods study was conducted among 202 consenting pregnant women in a rural Indian hospital between August 2014 and January 2015. Participants were provided with instructions on how to self-test using OraQuick(®) HIV antibody test, and subsequently asked to self-test under supervision of a community health worker. Test results were confirmed at a government-run integrated counselling and testing centre. A questionnaire was used to obtain information on patient demographics and the ease, acceptability and difficulties of self-testing. In-depth interviews were conducted with a sub-sample of 35 participants to understand their experiences. In total, 202 participants performed the non-invasive, oral fluid-based, rapid test under supervision for HIV screening. Acceptance rate was 100%. Motivators for self-testing included: ease of testing (43.4%), quick results (27.3%) and non-invasive procedure (23.2%). Sensitivity and specificity were 100% for 201 tests, and one test was invalid. Concordance of test result interpretation between community health workers and participants was 98.5% with a Cohen's Kappa (k) value of k=0.566 with pwomen in rural India. Participants were supportive of making self-testing publicly available. Policy guidelines and implementation research are required to advance HIV self-testing for larger populations at scale.

  11. Development of a fast agglutination screening test (FAST) for the detection of anti-Leishmania antibodies in dogs

    NARCIS (Netherlands)

    Schallig, H. D. F. H.; Schoone, G. J.; Beijer, E. G. M.; Kroon, C. C. M.; Hommers, M.; Ozbel, Y.; Ozensoy, S.; da Silva, E. S.; Cardoso, L. M.; da Silva, E. D.

    2002-01-01

    A fast agglutination screening test (FAST) for the detection of anti-Leishinania antibodies in serum samples from dogs with visceral leishmamosis was developed. The test is based on the direct agglutination test (DAT), but combines a higher parasite concentration with a smaller test volume. In

  12. Antibody or Antibody Fragments: Implications for Molecular Imaging and Targeted Therapy of Solid Tumors

    Directory of Open Access Journals (Sweden)

    Katerina T. Xenaki

    2017-10-01

    Full Text Available The use of antibody-based therapeutics has proven very promising for clinical applications in cancer patients, with multiple examples of antibodies and antibody–drug conjugates successfully applied for the treatment of solid tumors and lymphomas. Given reported recurrence rates, improvements are clearly still necessary. A major factor limiting the efficacy of antibody-targeted cancer therapies may be the incomplete penetration of the antibody or antibody–drug conjugate into the tumor. Incomplete tumor penetration also affects the outcome of molecular imaging, when using such targeting agents. From the injection site until they arrive inside the tumor, targeting molecules are faced with several barriers that impact intratumoral distribution. The primary means of antibody transport inside tumors is based on diffusion. The diffusive penetration inside the tumor is influenced by both antibody properties, such as size and binding affinity, as well as tumor properties, such as microenvironment, vascularization, and targeted antigen availability. Engineering smaller antibody fragments has shown to improve the rate of tumor uptake and intratumoral distribution. However, it is often accompanied by more rapid clearance from the body and in several cases also by inherent destabilization and reduction of the binding affinity of the antibody. In this perspective, we discuss different cancer targeting approaches based on antibodies or their fragments. We carefully consider how their size and binding properties influence their intratumoral uptake and distribution, and how this may affect cancer imaging and therapy of solid tumors.

  13. Determination of specificity and pattern of antinuclear antibodies (ana) in systemic rheumatic disease patients positive for ana testing

    International Nuclear Information System (INIS)

    Nawaz, H.; Bashir, M.M.; Iqbal, W.

    2018-01-01

    To determine probability of finding antinuclear antibodies (ANA) and anti extractable nuclear antigens (ENA) positive samples and associating ANA patterns with anti-ENA reactivities among a consecutive cohort of samples of systemic rheumatic disease patients referred for ANA testing. Study Design:Prospective cohort study. Place and Duration of Study:Immunology Department, Armed Forces Institute of Pathology, Rawalpindi, Pakistan, from January to June 2016. Methodology:All the samples referred for ANA testing with clinical suspicion of systemic rheumatic disease were included. After screening, ANA positive samples were subjected to anti-ENA antibodies testing (including anti-SSA, anti-SSB, anti-Sm, anti-RNP, anti-SCL-70 and anti-Jo-1 antibodies) and ANA pattern and titer determination. Results:Of 4,347 samples received, 397 were positive for ANA (9%). Of 397, 96 (24%) samples positive on ENA screen were tested for anti-ENA reactivity. Anti-SSA antibodies were found in 59 samples. Commonest ANA patterns were coarse and fine speckled (43 and 22 samples of 81 tested), while majority of samples carried ANA in titers of 1:40 and 1:80 (22 and 18 samples of 81 tested). No specific ANA pattern was associated with any particular anti-ENA reactivity. Conclusion:Among samples/patients referred for investigations of autoimmune disorders, probability of finding positive ANA is approximately 9%. Of these 9%, about 24% also show reactivity against ENA. Commonest ANA pattern is coarse speckled and majority of such patients carry ANA in titers ranging from 1:40 to 1:80. Commonest ENA reactivity was against SSA. (author)

  14. Development and Evaluation of a Rapid and Sensitive EBOV-RPA Test for Rapid Diagnosis of Ebola Virus Disease.

    Science.gov (United States)

    Yang, Mingjuan; Ke, Yuehua; Wang, Xuesong; Ren, Hang; Liu, Wei; Lu, Huijun; Zhang, Wenyi; Liu, Shiwei; Chang, Guohui; Tian, Shuguang; Wang, Lihua; Huang, Liuyu; Liu, Chao; Yang, Ruifu; Chen, Zeliang

    2016-06-01

    Confirming Ebola virus disease (EVD), a deadly infectious disease, requires real-time RT-PCR, which takes up to a few hours to yield results. Therefore, a rapid diagnostic assay is imperative for EVD diagnosis. A rapid nucleic acid test based on recombinase polymerase amplification (EBOV-RPA) was developed to specifically detect the 2014 outbreak strains. The EBOV-RPA assay was evaluated by testing samples from suspected EVD patients in parallel with RT-PCR. An EBOV-RPA, which could be completed in 20 min, was successfully developed. Of 271 patients who tested positive for Ebola virus by RT-PCR, 264 (sensitivity: 97%, 95% CI: 95.5-99.3%) were positive by EBOV-RPA; 101 of 104 patients (specificity: 97%, 95% CI: 93.9-100%) who tested negative by RT-PCR were also negative by EBOV-RPA. The sensitivity values for samples with a Ct value of RPA had significantly high Ct values. Results of external quality assessment samples with EBOV-RPA were 100%, consistent with those of RT-PCR. The EBOV-RPA assay showed 97% sensitivity and 97% specificity for all EVD samples tested, making it a rapid and sensitive test for EVD diagnosis.

  15. Anti‑livin antibodies in Hashimoto thyroiditis.

    Science.gov (United States)

    Baumann-Antczak, Aleksandra; Kosowicz, Jerzy; Zamysłowska, Hanna; Ruchała, Marek

    2012-01-01

    Livin belongs to the family of apoptosis inhibitors. High livin expression is observed in malignancies of the gastrointestinal tract, lungs, breast, and kidneys, but it is not present in differentiated adult tissues. In some malignant processes, anti‑livin antibodies are present. The aim of the study was to evaluate the prevalence of anti‑livin antibodies in Hashimoto thyroiditis, a disease characterized by rapid and widespread thyrocyte apoptosis. The study comprised 65 women with Hashimoto thyroiditis and the control group of 40 healthy women. In the majority of the patients, clinical manifestations of hypothyroidism were observed; all patients had high levels of serum antithyroid peroxidase antibodies. A solid‑phase radioimmunoassay in livin‑coated polyethylene tubes using 125I-labeled protein A was used to determine anti-livin antibodies. Significant amounts of anti-livin antibodies were reported in 18 patients (26.8%); 3 patients (4.6%) had borderline antibody levels; while in controls only 1 patient was positive (2.5%, P Hashimoto thyroiditis, an autoimmune process is more general and involves numerous autoantibodies including an antibody against apoptosis inhibitor - livin. Anti‑livin antibodies cannot serve only as a marker of malignancy because they are also present in autoimmune processes.

  16. Assessment of pathogenesis of infective endocarditis by plasma IgG antibody titer test against periodontal bacteria.

    Science.gov (United States)

    Isoshima, Daichi; Yamashiro, Keisuke; Matsunaga, Kazuyuki; Shinobe, Michitaka; Nakanishi, Nagako; Nakanishi, Izumi; Omori, Kazuhiro; Yamamoto, Tadashi; Takashiba, Shogo

    2017-10-01

    Oral bacteria cause infective endocarditis (IE), so severe periodontitis is thought to be high risk for IE. We suggest the identification of high-risk patients by an IgG antibody titer test against periodontal bacteria might become common screening test.

  17. Community Laboratory Testing for Cryptosporidium: Multicenter Study Retesting Public Health Surveillance Stool Samples Positive for Cryptosporidium by Rapid Cartridge Assay with Direct Fluorescent Antibody Testing.

    Directory of Open Access Journals (Sweden)

    Dawn M Roellig

    Full Text Available Cryptosporidium is a common cause of sporadic diarrheal disease and outbreaks in the United States. Increasingly, immunochromatography-based rapid cartridge assays (RCAs are providing community laboratories with a quick cryptosporidiosis diagnostic method. In the current study, the Centers for Disease Control and Prevention (CDC, the Association of Public Health Laboratories (APHL, and four state health departments evaluated RCA-positive samples obtained during routine Cryptosporidium testing. All samples underwent "head to head" re-testing using both RCA and direct fluorescence assay (DFA. Community level results from three sites indicated that 54.4% (166/305 of Meridian ImmunoCard STAT! positives and 87.0% (67/77 of Remel Xpect positives were confirmed by DFA. When samples were retested by RCA at state laboratories and compared with DFA, 83.3% (155/186 of Meridian ImmunoCard STAT! positives and 95.2% (60/63 of Remel Xpect positives were confirmed. The percentage of confirmed community results varied by site: Minnesota, 39.0%; New York, 63.9%; and Wisconsin, 72.1%. The percentage of confirmed community results decreased with patient age; 12.5% of community positive tests could be confirmed by DFA for patients 60 years of age or older. The percentage of confirmed results did not differ significantly by sex, storage temperature, time between sample collection and testing, or season. Findings from this study demonstrate a lower confirmation rate of community RCA positives when compared to RCA positives identified at state laboratories. Elucidating the causes of decreased test performance in order to improve overall community laboratory performance of these tests is critical for understanding the epidemiology of cryptosporidiosis in the United States (US.

  18. New tests to detect antiphospholipid antibodies: antiprothrombin (aPT) and anti-phosphatidylserine/prothrombin (aPS/PT) antibodies.

    Science.gov (United States)

    Sciascia, Savino; Khamashta, Munther A; Bertolaccini, Maria Laura

    2014-05-01

    Antiprothrombin antibodies have been proposed as potential new biomarkers for thrombosis and/or pregnancy morbidity in the setting of the antiphospholipid syndrome (APS). Antiprothrombin antibodies are commonly detected by ELISA, using prothrombin coated onto irradiated plates (aPT), or prothrombin in complex with phosphatidylserine (aPS/PT), as antigen. Although these antibodies can co-exist in the same patient, aPT and aPS/PT seem to belong to different populations of autoantibodies. Early research explored the role of antibodies to prothrombin as potential antigenic targets for the lupus anticoagulant (LA). To date their clinical significance is being investigated and their potential role in identifying patients at higher risk of developing thrombotic events or pregnancy morbidity is being probed.

  19. Correlation between the immunological condition and the results of immunoenzymatic tests in diagnosing infectious mononucleosis.

    Science.gov (United States)

    Tamaro, Giorgio; Donato, Michela; Princi, Tanja; Parco, Sergio

    2009-04-01

    A symptom-based diagnosis of infectious mononucleosis is not sufficiently accurate, since some clinical symptoms of infectious mononucleosis are also detected in other virally induced diseases. Moreover, not all patients suffering from infectious mononucleosis show circulating atypical lymphocytes, which are considered characteristic of this disease. Therefore, when this disorder is suspected, serum analyses are carried out to detect the presence of certain immunoglobulins associated with infectious mononucleosis in the patient's blood. The aim of this study was to evaluate the sensitivity and the specificity of a rapid test detecting heterophil antibodies in diagnosing infectious mononucleosis in a paediatric population. We considered 163 paediatric patients with suspected infectious mononucleosis and we tested their serums to detect heterophil antibodies (using an inexpensive and rapid test) and specific immunoglobulins directed against Epstein-Barr virus (EBV) (these assays are known to be characterized by high sensitivity and specificity, but are more expensive and time-consuming). By comparing the results of the rapid test with those of the other assays, we found that the sensitivity of the first test was 61.8%, whereas its specificity was sufficiently high (about 90%). We show that, in paediatric patients, the detection of heterophil antibodies is not a very sensitive test, therefore the determination of immunoglobulins against specific antigens of EBV is recommended.

  20. Impact of Uniform Methods on Interlaboratory Antibody Titration Variability: Antibody Titration and Uniform Methods.

    Science.gov (United States)

    Bachegowda, Lohith S; Cheng, Yan H; Long, Thomas; Shaz, Beth H

    2017-01-01

    -Substantial variability between different antibody titration methods prompted development and introduction of uniform methods in 2008. -To determine whether uniform methods consistently decrease interlaboratory variation in proficiency testing. -Proficiency testing data for antibody titration between 2009 and 2013 were obtained from the College of American Pathologists. Each laboratory was supplied plasma and red cells to determine anti-A and anti-D antibody titers by their standard method: gel or tube by uniform or other methods at different testing phases (immediate spin and/or room temperature [anti-A], and/or anti-human globulin [AHG: anti-A and anti-D]) with different additives. Interlaboratory variations were compared by analyzing the distribution of titer results by method and phase. -A median of 574 and 1100 responses were reported for anti-A and anti-D antibody titers, respectively, during a 5-year period. The 3 most frequent (median) methods performed for anti-A antibody were uniform tube room temperature (147.5; range, 119-159), uniform tube AHG (143.5; range, 134-150), and other tube AHG (97; range, 82-116); for anti-D antibody, the methods were other tube (451; range, 431-465), uniform tube (404; range, 382-462), and uniform gel (137; range, 121-153). Of the larger reported methods, uniform gel AHG phase for anti-A and anti-D antibodies had the most participants with the same result (mode). For anti-A antibody, 0 of 8 (uniform versus other tube room temperature) and 1 of 8 (uniform versus other tube AHG), and for anti-D antibody, 0 of 8 (uniform versus other tube) and 0 of 8 (uniform versus other gel) proficiency tests showed significant titer variability reduction. -Uniform methods harmonize laboratory techniques but rarely reduce interlaboratory titer variance in comparison with other methods.

  1. Effect of using heat-inactivated serum with the Abbott human T-cell lymphotropic virus type III antibody test.

    OpenAIRE

    Jungkind, D L; DiRenzo, S A; Young, S J

    1986-01-01

    The Abbott enzyme immunoassay (Abbott Laboratories, North Chicago, Ill.) for human T-cell lymphotropic virus type III (HTLV-III) antibody was evaluated to determine the effect of using heat-inactivated (56 degrees C for 30 min) serum as the sample. Each of 58 nonreactive serum samples gave a higher A492 value when tested after heat inactivation. Ten of the samples became reactive after heating. Heat-inactivated serum should not be used in the current Abbott HTLV-III antibody test, because thi...

  2. Quality control of radiolabeled antibodies through simultaneous determination of antibody concentration and specific activity using time-resolved interaction analysis and reverse kinetic fit

    International Nuclear Information System (INIS)

    Andersson, K.; Mihaylova, D.; Wang, E.; Abrahamsen, L.; Buijs, J.; Bjoerkelund, H.

    2015-01-01

    Full text of publication follows. With the advent of efficient methods for producing proteins that bind to a defined target, the number of radiolabeled proteins, and in particular antibodies, used for medical imaging and cancer therapy is increasing rapidly. In line with this increase, focus should be put on methods for the quality control (QC). Proper antibody quality is of fundamental importance to guarantee safety and consistent efficacy for the patient. Adequate QC procedures exist for small radiolabeled synthetic compounds like FDG, but antibody based radiopharmaceuticals are different. Proteins are much more complex and fragile than the synthetic compounds, and hence require new methods for adequate characterization and QC. Yet another complication is the labeling where there is a risk that a subpopulation of the protein is damaged to the level that it no longer binds the target. Therefore, a new toolbox is required to fulfill the quality characterization of radiolabeled antibodies. We have developed a QC assay for the simultaneous determination of antibody function, concentration and specific activity. The assay is based on time-resolved detection of the antibody interaction with antigen-coated magnetic beads in LigandTracer instruments. The resulting binding curve is evaluated using reverse kinetic fits, where the known interaction parameters of the antibody-antigen interaction are set constant while as the concentration and signal level are fitted. The assay takes approximately 2 hours and the majority of the time constitutes automated data collection in the instrument. The QC assay has been tested on multiple antibody-antigen interactions and consistently provides repeatable results for concentration and specific activity, both with coefficient of variation (CV) less than 15%. We believe that this QC assay can improve the quality of radiolabeled therapeutic antibodies. (authors)

  3. Effect of autolysis on the specificity of bovine spongiform encephalopathy rapid tests

    Directory of Open Access Journals (Sweden)

    Caramelli Maria

    2010-07-01

    Full Text Available Abstract Background Routine rapid testing for Bovine Spongiform Encephalopathy (BSE has highlighted some problems with BSE rapid test performance, the most significant being the number of initially reactive samples and the false positive results on autolyzed tissue. This point is important for BSE active surveillance in risk populations, because tissue autolysis is often unavoidable in routine cases. A robust test suitable for use on field material is therefore needed. To date, very limited information regarding the effect of autolysis on the robustness of rapid tests has been documented; therefore, the National Reference Centre for Animal Encephalopathies (CEA rapid test laboratory selected 450 autolyzed and negative brain stem samples from fallen stock bovines older than 24 months to assess the specificity of four tests approved for BSE active surveillance: Biorad TeSeE, Enfer TSE version 2.0, Prionics® Check LIA, and IDEXX Herd Check BSE Antigen Kit EIA. The samples were graded according to the degree of autolysis and then dissected into five portions, four of which randomly assigned to processing by rapid tests and one to be available for confirmatory Western blot analysis. Findings The specificity of the four systems was 100% for all three grades of autolysis, while the percentage of initially reactive results was 0.00 (95%CI 0.00-0.82, 0.22 (95%CI 0.006-1.23, 0.44 (95%CI 0.05-1.60, and 0.89 (95%CI 0.24-2.26 for the Biorad TeSeE, the Prionics® Check LIA, the IDEXX Herd Check BSE and the Enfer TSE tests, respectively. No association with the degree of autolysis could be drawn. Conclusions The present study demonstrates that the four rapid tests can be considered well-running diagnostic tools regardless of tissue quality; nevertheless, the number of initial reactive samples reported for some systems must not be underestimated in routine testing. Furthermore the compliance with the reported performance can be guaranteed only when an ongoing

  4. Efficacy of immunoassay chromatography test for hepatitis-C antibodies detection

    International Nuclear Information System (INIS)

    Batool, A.; Khan, M.I.; Bano, K.A.

    2009-01-01

    To asses the efficacy of commercially available tests device method for anti HCV detection. Methods: Total 2000 blood samples for detection of anti HCV were screened initially by immuno chromatographic method. Those found positive on initial screening were re-tested by ELISA method at the Biochemistry Laboratory of the Pakistan Medical Research Council, Fatima Jinnah Medical College, Lahore. Results: Out of a total of 2,000 blood samples, 177 were found to be initially reactive/positive for anti-HCV with immuno chromatographic method. When these reactive/positive samples were retested for confirmation with ELISA, 47 blood samples were found to have tested falsely positive for anti-HCV. Overall 2.35% of blood samples were found to be tested false positive for anti-HCV by immuno chromatographic device method. Conclusions: Immuno chromatographic device method test is rapid and simple, which can be used in setting with limited facility when rapid testing is required. However it should not be used as sole criteria for diagnosis but should serve the purpose of initial screening only. Further research is required to establish the reliability of such devices for their specificity and sensitivity. (author)

  5. Antiprothrombin Antibodies

    Directory of Open Access Journals (Sweden)

    Polona Žigon

    2015-05-01

    Full Text Available In patients with the antiphospholipid syndrome (APS, the presence of a group of pathogenic autoantibodies called antiphospholipid antibodies causes thrombosis and pregnancy complications. The most frequent antigenic target of antiphospholipid antibodies are phospholipid bound β2-glycoprotein 1 (β2GPI and prothrombin. The international classification criteria for APS connect the occurrence of thrombosis and/or obstetric complications together with the persistence of lupus anticoagulant, anti-cardiolipin antibodies (aCL and antibodies against β2GPI (anti-β2GPI into APS. Current trends for the diagnostic evaluation of APS patients propose determination of multiple antiphospholipid antibodies, among them also anti-prothrombin antibodies, to gain a common score which estimates the risk for thrombosis in APS patients. Antiprothrombin antibodies are common in APS patients and are sometimes the only antiphospholipid antibodies being elevated. Methods for their determination differ and have not yet been standardized. Many novel studies confirmed method using phosphatidylserine/prothrombin (aPS/PT ELISA as an antigen on solid phase encompass higher diagnostic accuracy compared to method using prothrombin alone (aPT ELISA. Our research group developed an in-house aPS/PT ELISA with increased analytical sensitivity which enables the determination of all clinically relevant antiprothrombin antibodies. aPS/PT exhibited the highest percentage of lupus anticoagulant activity compared to aCL and anti-β2GPI. aPS/PT antibodies measured with the in-house method associated with venous thrombosis and presented the strongest independent risk factor for the presence of obstetric complications among all tested antiphospholipid antibodies

  6. Development of an immunochromatographic assay for the rapid detection of bromoxynil in water

    International Nuclear Information System (INIS)

    Zhu Jiang; Chen Wenchao; Lu Yitong; Cheng Guohua

    2008-01-01

    A rapid immunochromatographic one-step strip test was developed to specifically determine bromoxynil in surface and drinking water by competitive inhibition with the nano colloidal gold-conjugated monoclonal antibody (mAb). Bromoxynil standard samples of 0.01-10 mg L -1 in water were tested by this method and the visual limit was 0.06 mg L -1 . The assay only required 5 min and one-step by dispensing a drop of sample solution onto a strip. Parallel analysis of water samples with bromoxynil showed comparable results from one-step strip test and ELISA. Therefore, the one-step strip test is very useful as a screening method for qualitative detection of bromoxynil in water. - One-step strip test is a rapid method for qualitative detection of bromoxynil residues in water

  7. Anti-idiotypic antibodies to poliovirus antibodies in commercial immunoglubulin preparations, human serum and milk.

    NARCIS (Netherlands)

    M. Hahn-Zoric; B. Carlsson; S. Jeansson; H.P. Ekre; A.D.M.E. Osterhaus (Albert); D. Roberton; L.A. Hanson

    1993-01-01

    textabstractOur previous studies have suggested that fetal antibody production can be induced by maternal antiidiotypic antibodies transferred to the fetus via the placenta. We tested commercial Ig, sera, and milk for the presence of anti-idiotypic antibodies to poliovirus type 1, using affinity

  8. Determining the feline immunodeficiency virus (FIV) status of FIV-vaccinated cats using point-of-care antibody kits.

    Science.gov (United States)

    Westman, Mark E; Malik, Richard; Hall, Evelyn; Sheehy, Paul A; Norris, Jacqueline M

    2015-10-01

    This study challenges the commonly held view that the feline immunodeficiency virus (FIV) infection status of FIV-vaccinated cats cannot be determined using point-of-care antibody test kits due to indistinguishable antibody production in FIV-vaccinated and naturally FIV-infected cats. The performance of three commercially available point-of-care antibody test kits was compared in a mixed population of FIV-vaccinated (n=119) and FIV-unvaccinated (n=239) cats in Australia. FIV infection status was assigned by considering the results of all antibody kits in concert with results from a commercially available PCR assay (FIV RealPCR™). Two lateral flow immunochromatography test kits (Witness FeLV/FIV; Anigen Rapid FIV/FeLV) had excellent overall sensitivity (100%; 100%) and specificity (98%; 100%) and could discern the true FIV infection status of cats, irrespective of FIV vaccination history. The lateral flow ELISA test kit (SNAP FIV/FeLV Combo) could not determine if antibodies detected were due to previous FIV vaccination, natural FIV infection, or both. The sensitivity and specificity of FIV RealPCR™ for detection of viral and proviral nucleic acid was 92% and 99%, respectively. These results will potentially change the way veterinary practitioners screen for FIV in jurisdictions where FIV vaccination is practiced, especially in shelter scenarios where the feasibility of mass screening is impacted by the cost of testing. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  9. [Efficient and rapid non-test tube cloning of Jatropha curcas].

    Science.gov (United States)

    Wang, Zhao-Yu; Lin, Jing-Ming; Xu, Zeng-Fu

    2007-08-01

    To develop a new technique for efficient and rapid non-test tube cloning of the medicinal and energy- producing plant Jatropha curcas. Using the mini-stem fragment (2-3 cm) of Jatropha curcas with merely one axillary bud as the explant, the effect of an auxin IBA concentration on the plantlet regeneration was studied. When treated with 1 mg/LIBA for 1h, the explants showed the most rapid propagation. The mini-stem fragments high root regeneration ratio (96.7%), short root regeneration period (18.2-/+2.0 d), large number of new roots per explant (6.3-/+1.8), and long total root length (6.8-/+3.5 cm), demonstrating that this technique can be a simple and efficient method for rapid non-test tube cloning of Jatropha curcas of potential industrial value.

  10. A low cost, safe, disposable, rapid and self-sustainable paper-based platform for diagnostic testing: lab-on-paper

    International Nuclear Information System (INIS)

    Costa, M N; Veigas, B; Jacob, J M; Santos, D S; Martins, R; Fortunato, E; Gomes, J; Inácio, J; Baptista, P V

    2014-01-01

    There is a strong interest in the use of biopolymers in the electronic and biomedical industries, mainly towards low-cost applications. The possibility of developing entirely new kinds of products based on cellulose is of current interest, in order to enhance and to add new functionalities to conventional paper-based products. We present our results towards the development of paper-based microfluidics for molecular diagnostic testing. Paper properties were evaluated and compared to nitrocellulose, the most commonly used material in lateral flow and other rapid tests. Focusing on the use of paper as a substrate for microfluidic applications, through an eco-friendly wax-printing technology, we present three main and distinct colorimetric approaches: (i) enzymatic reactions (glucose detection); (ii) immunoassays (antibodies anti-Leishmania detection); (iii) nucleic acid sequence identification (Mycobacterium tuberculosis complex detection). Colorimetric glucose quantification was achieved through enzymatic reactions performed within specific zones of the paper-based device. The colouration achieved increased with growing glucose concentration and was highly homogeneous, covering all the surface of the paper reaction zones in a 3D sensor format. These devices showed a major advantage when compared to the 2D lateral flow glucose sensors, where some carryover of the coloured products usually occurs. The detection of anti-Leishmania antibodies in canine sera was conceptually achieved using a paper-based 96-well enzyme-linked immunosorbent assay format. However, optimization is still needed for this test, regarding the efficiency of the immobilization of antigens on the cellulose fibres. The detection of Mycobacterium tuberculosis nucleic acids integrated with a non-cross-linking gold nanoprobe detection scheme was also achieved in a wax-printed 384-well paper-based microplate, by the hybridization with a species-specific probe. The obtained results with the above

  11. A low cost, safe, disposable, rapid and self-sustainable paper-based platform for diagnostic testing: lab-on-paper

    Science.gov (United States)

    Costa, M. N.; Veigas, B.; Jacob, J. M.; Santos, D. S.; Gomes, J.; Baptista, P. V.; Martins, R.; Inácio, J.; Fortunato, E.

    2014-03-01

    There is a strong interest in the use of biopolymers in the electronic and biomedical industries, mainly towards low-cost applications. The possibility of developing entirely new kinds of products based on cellulose is of current interest, in order to enhance and to add new functionalities to conventional paper-based products. We present our results towards the development of paper-based microfluidics for molecular diagnostic testing. Paper properties were evaluated and compared to nitrocellulose, the most commonly used material in lateral flow and other rapid tests. Focusing on the use of paper as a substrate for microfluidic applications, through an eco-friendly wax-printing technology, we present three main and distinct colorimetric approaches: (i) enzymatic reactions (glucose detection); (ii) immunoassays (antibodies anti-Leishmania detection); (iii) nucleic acid sequence identification (Mycobacterium tuberculosis complex detection). Colorimetric glucose quantification was achieved through enzymatic reactions performed within specific zones of the paper-based device. The colouration achieved increased with growing glucose concentration and was highly homogeneous, covering all the surface of the paper reaction zones in a 3D sensor format. These devices showed a major advantage when compared to the 2D lateral flow glucose sensors, where some carryover of the coloured products usually occurs. The detection of anti-Leishmania antibodies in canine sera was conceptually achieved using a paper-based 96-well enzyme-linked immunosorbent assay format. However, optimization is still needed for this test, regarding the efficiency of the immobilization of antigens on the cellulose fibres. The detection of Mycobacterium tuberculosis nucleic acids integrated with a non-cross-linking gold nanoprobe detection scheme was also achieved in a wax-printed 384-well paper-based microplate, by the hybridization with a species-specific probe. The obtained results with the above

  12. Evaluation of a bovine antibody test for diagnosing Mycobacterium avium complex in patients with cystic fibrosis

    DEFF Research Database (Denmark)

    Qvist, Tavs; Pressler, Tacjana; Katzenstein, Terese L.

    2017-01-01

    Introduction: The aim of this study was to test a commercial bovine enzyme-linked immunosorbent assay for investigating antibody activity against Mycobacterium avium complex. Methods: All patients at the Copenhagen Cystic Fibrosis (CF) Center who had culture for nontuberculous mycobacteria...... before and after culture conversion was performed in case patients. Results: Out of 286 included subjects, six had clinical M. avium complex pulmonary disease at the time of sera sampling. These patients presented with higher antibody test values (P-value ... at ruling out pulmonary disease. Screening sera from patients with CF could guide clinicians to focus attention on patients at higher risk of M. avium complex pulmonary disease. Pediatr Pulmonol. 2017;52:34–40....

  13. A Laboratory-Based Evaluation of Four Rapid Point-of-Care Tests for Syphilis

    Science.gov (United States)

    Causer, Louise M.; Kaldor, John M.; Fairley, Christopher K.; Donovan, Basil; Karapanagiotidis, Theo; Leslie, David E.; Robertson, Peter W.; McNulty, Anna M.; Anderson, David; Wand, Handan; Conway, Damian P.; Denham, Ian; Ryan, Claire; Guy, Rebecca J.

    2014-01-01

    Background Syphilis point-of-care tests may reduce morbidity and ongoing transmission by increasing the proportion of people rapidly treated. Syphilis stage and co-infection with HIV may influence test performance. We evaluated four commercially available syphilis point-of-care devices in a head-to-head comparison using sera from laboratories in Australia. Methods Point-of-care tests were evaluated using sera stored at Sydney and Melbourne laboratories. Sensitivity and specificity were calculated by standard methods, comparing point-of-care results to treponemal immunoassay (IA) reference test results. Additional analyses by clinical syphilis stage, HIV status, and non-treponemal antibody titre were performed. Non-overlapping 95% confidence intervals (CI) were considered statistically significant differences in estimates. Results In total 1203 specimens were tested (736 IA-reactive, 467 IA-nonreactive). Point-of-care test sensitivities were: Determine 97.3%(95%CI:95.8–98.3), Onsite 92.5%(90.3–94.3), DPP 89.8%(87.3–91.9) and Bioline 87.8%(85.1–90.0). Specificities were: Determine 96.4%(94.1–97.8), Onsite 92.5%(90.3–94.3), DPP 98.3%(96.5–99.2), and Bioline 98.5%(96.8–99.3). Sensitivity of the Determine test was 100% for primary and 100% for secondary syphilis. The three other tests had reduced sensitivity among primary (80.4–90.2%) compared to secondary syphilis (94.3–98.6%). No significant differences in sensitivity were observed by HIV status. Test sensitivities were significantly higher among high-RPR titre (RPR≥8) (range: 94.6–99.5%) than RPR non-reactive infections (range: 76.3–92.9%). Conclusions The Determine test had the highest sensitivity overall. All tests were most sensitive among high-RPR titre infections. Point-of-care tests have a role in syphilis control programs however in developed countries with established laboratory infrastructures, the lower sensitivities of some tests observed in primary syphilis suggest these would

  14. Plasma exchange to remove HIT antibodies: dissociation between enzyme-immunoassay and platelet activation test reactivities.

    Science.gov (United States)

    Warkentin, Theodore E; Sheppard, Jo-Ann I; Chu, F Victor; Kapoor, Anil; Crowther, Mark A; Gangji, Azim

    2015-01-01

    Repeated therapeutic plasma exchange (TPE) has been advocated to remove heparin-induced thrombocytopenia (HIT) IgG antibodies before cardiac/vascular surgery in patients who have serologically-confirmed acute or subacute HIT; for this situation, a negative platelet activation assay (eg, platelet serotonin-release assay [SRA]) has been recommended as the target serological end point to permit safe surgery. We compared reactivities in the SRA and an anti-PF4/heparin IgG-specific enzyme immunoassay (EIA), testing serial serum samples in a patient with recent (subacute) HIT who underwent serial TPE precardiac surgery, as well as for 15 other serially-diluted HIT sera. We observed that post-TPE/diluted HIT sera-when first testing SRA-negative-continue to test strongly positive by EIA-IgG. This dissociation between the platelet activation assay and a PF4-dependent immunoassay for HIT antibodies indicates that patients with subacute HIT undergoing repeated TPE before heparin reexposure should be tested by serial platelet activation assays even when their EIAs remain strongly positive. © 2015 by The American Society of Hematology.

  15. Patho-TB test for the rapid diagnosis of pulmonary tuberculosis

    Directory of Open Access Journals (Sweden)

    Roya Alavi-Naini

    2009-09-01

    Full Text Available

    • BACKGROUND: Despite recent technologic improvements in identifying mycobacterium tuberculosis, we are still facing problems in rapid diagnosis of tuberculosis. The objective of this study is to determine the diagnostic value of a new rapid screening test (Patho-TB™ for diagnosis of pulmonary tuberculosis.
    • METHODS: Between September 2006 to August 2007, 178 patients were enrolled in the study who were finally classified into two groups; a group of documented pulmonary tuberculosis (n = 67 and a group of non-tuberculous pulmonary infection (n = 111. Patho-TB™ test, Ziehl-Neelsen staining and culture were done on all specimens.
    • RESULTS: Of all, 43 patients with pulmonary tuberculosis were sputum smear positive for acid fast bacilli and the rest were smear negative. Mean age of the patients was 59.8 ± 16.1 years and 44% of them were men. The results of Patho- TB™ test were positive in 40 of smear positive and 20 of smear negative tuberculous patients and 33 cases of nontuberculous control group. The sensitivity, specificity, positive and negative predictive values and accuracy of Patho- TB™ test were estimated 89.5%, 70.2%, 64.5%, 91.7% and 77.5%, respectively.
    • CONCLUSIONS: According to the present study it would be suggested that Patho-TB™ test could be a rapid and inexpensive method for diagnosis of pulmonary tuberculosis, given by its high sensitivity and negative predictive value. Concerning the high number of false positive results, using a confirmatory diagnostic procedure is mandatory.
    • KEYWORDS: Pulmonary Tuberculosis, Rapid Diagnosis, Mycobacterium Tuberculosis Antigens, Iran

  16. Express immunochromatographic detection of antibodies against Brucella abortus in cattle sera based on quantitative photometric registration and modulated cut-off level.

    Science.gov (United States)

    Sotnikov, Dmitriy V; Byzova, Nadezhda A; Zherdev, Anatoly V; Eskendirova, Saule Z; Baltin, Kairat K; Mukanov, Kasim K; Ramankulov, Erlan M; Sadykhov, Elchin G; Dzantiev, Boris B

    2015-01-01

    An immunochromatographic test system was developed for rapid detection of the levels of specific IgG antibodies to Brucella abortus lipopolysaccharide, as a tool for diagnosis of brucellosis in cattle. The pilot test strips were examined using blood sera from sick (78 samples) and healthy (35 samples) cows. The results obtained by immunochromatographic assay, using a portable optical densitometer for digital video detection, correlate well with the results obtained by immunoenzyme assay and are in agreement with the results of the disease diagnosis. The new test system allows detection of antibodies within 10 min and can be proposed as an alternative to the methods available for serodiagnosis of brucellosis.

  17. Effect of haemolysis and repeated freeze-thawing cycles on wild boar serum antibody testing by ELISA

    Directory of Open Access Journals (Sweden)

    Boadella Mariana

    2011-11-01

    Full Text Available Abstract Background Monitoring wildlife diseases is needed to identify changes in disease occurrence. Wildlife blood samples are valuable for this purpose but are often gathered haemolysed. To maximise information, sera often go through repeated analysis and freeze-thaw cycles. Herein, we used samples of clean and haemolysed Eurasian wild boar (Sus scrofa serum stored at -20°C and thawed up to five times to study the effects of both treatments on the outcome of a commercial ELISA test for the detection of antibodies against Suid Herpesvirus 1 (ADV. Results The estimated prevalence of antibodies against ADV was 50-53% for clean and haemolysed sera. Hence, haemolysis did not reduce the mean observed serum antibody prevalence. However, 10 samples changed their classification after repeated freeze-thawing. This included 3 (15% of the clean sera and 7 (41% of the haemolysed sera. Conclusions We recommend (1 establishing more restrictive cut-off values when testing wildlife sera, (2 recording serum quality prior to sample banking, (3 recording the number of freezing-thawing cycles and (4 store sera in various aliquots to reduce repeated usage. For instance, sera with more than 3 freeze-thaw cycles and a haemolysis of over 3 on a scale of 4 should better be discarded for serum antibody monitoring. Even clean (almost not haemolysed sera should not go through more than 5 freeze-thaw cycles.

  18. Antibodies against glucan, chitin, and Saccharomyces cerevisiae mannan as new biomarkers of Candida albicans infection that complement tests based on C. albicans mannan.

    Science.gov (United States)

    Sendid, B; Dotan, N; Nseir, S; Savaux, C; Vandewalle, P; Standaert, A; Zerimech, F; Guery, B P; Dukler, A; Colombel, J F; Poulain, D

    2008-12-01

    Antibodies against Saccharomyces cerevisiae mannan (ASCA) and antibodies against synthetic disaccharide fragments of glucans (ALCA) and chitin (ACCA) are biomarkers of Crohn's disease (CD). We previously showed that Candida albicans infection generates ASCA. Here, we explored ALCA and ACCA as possible biomarkers of invasive C. albicans infection (ICI). ASCA, ALCA, ACCA, and Candida mannan antigen and antibody detection tests were performed on 69 sera obtained sequentially from 18 patients with ICIs proven by blood culture, 59 sera from CD patients, 47 sera from hospitalized subjects colonized by Candida species (CZ), and 131 sera from healthy controls (HC). ASCA, ALCA, and ACCA levels in CD and ICI patients were significantly different from those in CZ and HC subjects (PACCA, and Platelia Candida tests, 100% of ICIs were detected, with the kinetics of the antibody response depending on the patient during the time course of infection. A large number of sera presented with more than three positive tests. This is the first evidence that the detection of antibodies against chitin and glucans has diagnostic value in fungal infections and that these tests can complement more specific tests. Future trials are necessary to assess the value of these tests in multiparametric analysis, as well as their pathophysiological relevance.

  19. Anti-smooth muscle antibody

    Science.gov (United States)

    ... gov/ency/article/003531.htm Anti-smooth muscle antibody To use the sharing features on this page, please enable JavaScript. Anti-smooth muscle antibody is a blood test that detects the presence ...

  20. Conference scene: progress with promising human antibodies.

    Science.gov (United States)

    Larrick, James W

    2012-03-01

    Antibodies and antibody-based therapeutics have become big business, with annual sales over US$50 billion, accounting for >6% of worldwide pharmaceutical revenues. Ten molecules have blockbuster status (>US$1 billion), with six generating more than US$6 billion in sales. In excess of 300 products based on this rapidly maturing technology are in clinical trials. The generation and manufacture of human antibodies is now routine, although the cost of goods remains an issue. Optimizing combinations of antibodies with other therapeutics (e.g., chemotherapy) is a major short-term goal, while target validation and product differentiation remain significant hurdles if growth is to continue. Some of the notable highlights of the recent 16th International Conference on Human Antibodies and Hybridomas meeting in Cannes, France are described below. The conference was sponsored by the international journal Human Antibodies, in association with the Integrative Medical Sciences Association (IMSA). The Program Chairman was Professor Mark Glassy, IMSA, San Diego, CA, USA.

  1. Application of solid-phase antibodies to radioimmunoassay

    International Nuclear Information System (INIS)

    McConway, M.G.; Chapman, R.S.

    1986-01-01

    Two types of polymeric microparticle, Dynospheres and reprecipitated acid-hydrolysed nylon 6/6, and two methods of activating these particles with either tresyl chloride or carbonyldiimidazole (CDI) prior to covalent linkage of antibodies were investigated with a view towards their respective adoption for the preparation of general solid-phase reagents for immunoassay applications. Activation of each particle and coupling of antibodies was rapid irrespective of the activator. CDI proved to be the activator of choice since it was cheap, less hazardous, more efficient and less pH dependent than tresyl chloride. Both types of microparticle remain buoyant during the RIA incubation periods and form stable pellets after centrifugation. In second antibody applications immobilisation of the first antibody occurs with a short incubation period of 30 min. Nylon microparticles have a higher antibody-coupling capacity and are the particles of choice in both first and second antibody applications. However, the nylon microparticles possess marginally higher non-specific binding characteristics. (Auth.)

  2. Plasmapheresis Responsive Rapid Onset Dementia with Predominantly Frontal Dysfunction in the Context of Hashimoto’s Encephalopathy

    Directory of Open Access Journals (Sweden)

    Dominique Endres

    2017-10-01

    Full Text Available BackgroundHashimoto’s encephalopathy (HE is a rare immunological neuropsychiatric disorder characterized by increased antithyroid antibodies and mixed neurological and psychiatric symptoms. HE has been previously discussed as a differential diagnosis for rapid progressive dementia. However, most of these patients suffered from additional neurological symptoms, like ataxia or seizures.Case presentationHere, we present the case of a 59-year-old female patient suffering rapid onset dementia with salient frontal executive dysfunction. She developed rapid onset symptoms, including apathy, verbal depletion up to a stuporous state, severe working memory deficits, evidence of primitive reflexes, disturbed Luria’s three-step test, and micturition disorder. Analysis of her cerebrospinal fluid was normal. The serum analyses showed increased antithyroid (antithyroid peroxidase and antithyroglobulin antibodies. In the cerebral magnetic resonance imaging, supratentorial deep and peripheral white matter lesions were found; the electroencephalography showed intermittent slowing, and the [18F]fluorodeoxyglucose positron emission tomography (FDG-PET depicted medial and superior dorsolateral frontal hypometabolism. Several different psychopharmacological therapeutic approaches with various neuroleptics, antidepressants, and high doses of lorazepam were unsuccessful. Due to the organic alterations, including increased antithyroid antibodies, HE was suspected. Against expectations, treatment with high-dose corticosteroids proved to be ineffective and was associated with worsening symptoms. However, escalated treatment with plasmapheresis over 5 days led to significant improvement in all reported symptoms and in psychometric testing. The neuropsychological improvement was stable over a 6-month follow-up period, and the FDG-PET normalized.ConclusionThis case report reveals that (1 HE can mimic rapid onset dementia with predominantly frontal dysfunction; (2 this

  3. Rabies direct fluorescent antibody test does not inactivate rabies or eastern equine encephalitis viruses.

    Science.gov (United States)

    Jarvis, Jodie A; Franke, Mary A; Davis, April D

    2016-08-01

    An examination using the routine rabies direct fluorescent antibody test was performed on rabies or Eastern equine encephalitis positive mammalian brain tissue to assess inactivation of the virus. Neither virus was inactivated with acetone fixation nor the routine test, thus laboratory employees should treat all samples as rabies and when appropriate Eastern equine encephalitis positive throughout the whole procedure. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Transfer plate radioassay using cell monolayers to detect anti-cell surface antibodies synthesized by lymphocyte hybridomas

    International Nuclear Information System (INIS)

    Schneider, M.D.; Eisenbarth, G.S.

    1979-01-01

    A solid phase [ 125 I] Protein A radioassay for anti-cell surface antibodies is described, which employs target cell monolayers cultured on fenestrated polyvinyl chloride 96-well plates ('transfer plates'). The calibrated aperture in the bottom of each well is small enough to retain fluid contents by surface tension during monolayer growth, but also permits fluid to enter the wells when transfer plate are lowered into receptacles containing washing buffer on test sera. To assay for antibodies directed against target cell surface antigens, transfer plates bearing monolayers are inserted into microculture plates with corresponding 96-well geometry, thereby simultaneously sampling 96 wells. This assay allows rapid screening of hundreds of hybrid cell colonies for production of antibodies with desired tissue specificity. (Auth.)

  5. Clinical comparison of the Treponema pallidum CAPTIA syphilis-G enzyme immunoassay with the fluorescent treponemal antibody absorption immunoglobulin G assay for syphilis testing.

    Science.gov (United States)

    Halling, V W; Jones, M F; Bestrom, J E; Wold, A D; Rosenblatt, J E; Smith, T F; Cockerill, F R

    1999-10-01

    Recently, a treponema-specific immunoglobulin G (IgG) enzyme immunoassay (EIA), the CAPTIA Syphilis-G (Trinity Biotech, Jamestown, N.Y.), has become available as a diagnostic test for syphilis. A total of 89 stored sera previously tested by the fluorescent treponemal antibody absorption (FTA-ABS) IgG assay were evaluated by the CAPTIA EIA. The FTA-ABS IgG procedure was performed by technologists unblinded to results of rapid plasmid reagin (RPR) testing of the same specimens. Borderline CAPTIA-positive samples (antibody indices of >/=0.650 and 0.900, the sample was considered positive. Thirteen of 89 (15%) samples had discrepant results. Compared to the FTA-ABS assay, the CAPTIA EIA had a sensitivity and specificity and positive and negative predictive values of 70.7, 97.9, 96.7, and 79.7%, respectively. In another analysis, discrepancies between results were resolved by repeated FTA-ABS testing (technologists were blinded to previous RPR results) and patient chart reviews. Seven CAPTIA-negative samples which were previously interpreted (unblinded) as minimally reactive by the FTA method were subsequently interpreted (blinded) as nonreactive. One other discrepant sample (CAPTIA negative and FTA-ABS positive [at an intensity of 3+], unblinded) was FTA negative with repeated testing (blinded). For the five remaining discrepant samples, chart reviews indicated that one patient (CAPTIA negative and FTA-ABS positive [minimally reactive], blinded) had possible syphilis. These five samples were also evaluated and found to be negative by another treponema-specific test, the Treponema pallidum microhemagglutination assay. Therefore, after repeated testing and chart reviews, 2 of the 89 (2%) samples had discrepant results; the adjusted sensitivity, specificity, and positive and negative predictive values were 96.7, 98.3, 96.7, and 98.3%, respectively. This study demonstrates that the CAPTIA IgG EIA is a reliable method for syphilis testing and that personnel performing tests

  6. A population screening test for antibody to measles virus

    International Nuclear Information System (INIS)

    Friedman, M.G.

    1981-01-01

    In areas where sporadic cases of measles continue to occur in spite of vaccination programs, the availability of a simple screening test for determination of seropositivity to measles virus is desirable. A sensitive radioimmunoassay (RIA) screening test (ST) for the detection of IgG antibody to measles virus, based on a solid phase RIA, is described. The assays were performed on polyvinyl microtiter plates for which the RIAST requires only 5 μl of serum per subject. Antigen consisted of a sonicated extract of measles virus-infected Vero cells. Rabbit antihuman IgG specific for the Fc-segment of human IgG, labelled with 125 I, was used to detect human IgG bound to viral antigen. The basic RIA method was characterized by carrying out full titrations of sera of 53 healthy adults, 10 children, and 13 patients with measles-associated illness. These sera were also tested by the hemagglutination inhibition (HI) technique; most of the measles sera were also tested by complement fixation (CF). RIAST results (expressed as binding ratios) obtained for 52 healthy adults are compared with their RIA serum titers. Of the 200 sera of patients of various ages tested by the RIAST, 63 borderline sera were also tested by HI. The RIAST, which does not require serum treatment other than inactivation, proved to be more sensitive as an indicator of seropositivity than HI. Implications of the results and practical applications of the screening test are discussed. (author)

  7. Localization, kinetics and metabolism of labelled monoclonal antibodies on a cellular level

    International Nuclear Information System (INIS)

    Steinstraesser, A.; Kuhlmann, L.; Zimmer, M.; Schwarz, A.

    1988-01-01

    In order to gain insight into the mechanisms, the localization, kinetics and metabolism of preparations labelled with 131 J and 111 In were examined on a cellular level. Micro-autoradiography for histological assessment of the storage tissue in the organs was complemented by cytological examination methods for assessing the extent of internalisation of the antibodies, and the metabolism of the antibodies in the cytosol fraction could be followed up by chromatography. One of the major results is that even with the complete antibody, accumulation in the liver cells proceeds very rapidly and protein degradation is practically completed within twenty-four hours. In the tumor, however, internalisation plays a minor part (about 80 p.c. of the antibodies remain bound to the membrane). Rapid accumulation of the antibodies by the tubulus epithelium of the kidney causes the intensive image of the renal scintiscan. (orig./MG) [de

  8. [Study of anti-idiotype antibodies to human monoclonal antibody].

    Science.gov (United States)

    Harada, R; Takahashi, N; Owaki, I; Kannagi, R; Endo, N; Morita, N; Inoue, M

    1992-02-01

    A human monoclonal antibody, ll-50 (IgM, lambda), was generated, which reacted specifically with a major of glycolipid present in LS174T colon cancer cells. The glycolipid antigen which reacted with the ll-50 antibody was expected to four sugar residues from its TLC mobility, and it was ascertained that the glycolipid antigen which reacted with ll-50 antibody might be Lc4 antigen [Gal beta 1----3 GLcNAc beta 1----3 Gal beta 1----4 Glc beta 1----1 Cer] judging from TLC immunostaining and ELISA when the reactivity of ll-50 antibody was tested using various pure glycolipids in 3-5 sugar residues as an antigen. Sera in patients with malignant disorders and healthy individuals were analyzed by Sandwich assay of immobilized and biotinylated ll-50 antibody. The serum of the Lc4 antigen recognized by ll-50 antibody was significantly higher in patients with malignant disorders than that in healthy individuals (p less than 0.05). Three mouse monoclonal anti-idiotype antibodies, G3, B3 and C5 (all IgG1), were generated by the immunization of BALB/c mice with ll-50 antibody. These anti-idiotype antibodies specifically bound to to human monoclonal antibody, ll-50 and had a significant inhibitory activity towards the binding of ll-50 antibody to the Lc4 antigen. This indicated that these anti-idiotype antibodies, G3, B3, and C5, were paratope-related anti-idiotype antibodies. G3, B3, and C5 were expected to define the nearest idiotope because they could mutually inhibit ll-50 antibody. Sera in patients with malignant disorders and healthy individuals were analyzed by Sandwich assay of immobilized and biotinylated anti-idiotype antibodies, G3, B3, and C5. As to the ll-50 like antibodies defined by C5 (Id-C5+), the mean serum level in patients with malignant disorders was significantly higher than that in healthy individuals (p less than 0.05). As to the ll-50 like antibodies defined by B3 (Id-B3+), the mean serum level in patients with malignant disorders was significantly higher

  9. Software testing for evolutionary iterative rapid prototyping

    OpenAIRE

    Davis, Edward V., Jr.

    1990-01-01

    Approved for public release; distribution unlimited. Rapid prototyping is emerging as a promising software development paradigm. It provides a systematic and automatable means of developing a software system under circumstances where initial requirements are not well known or where requirements change frequently during development. To provide high software quality assurance requires sufficient software testing. The unique nature of evolutionary iterative prototyping is not well-suited for ...

  10. [Rapid test for detection of susceptibility to cefotaxime in Enterobacteriaceae].

    Science.gov (United States)

    Jiménez-Guerra, Gemma; Hoyos-Mallecot, Yannik; Rodríguez-Granger, Javier; Navarro-Marí, José María; Gutiérrez-Fernández, José

    In this work an "in house" rapid test based on the change in pH that is due to hydrolysis for detecting Enterobacteriaceae susceptible to cefotaxime is evaluated. The strains of Enterobacteriaceae from 1947 urine cultures were assessed using MicroScan panels and the "in house" test. This rapid test includes red phenol solution and cefotaxime. Using MicroScan panels, 499 Enterobacteriaceae isolates were evaluated, which included 27 isolates of Escherichia coli producing extended-spectrum beta-lactamases (ESBL), 16 isolates of Klebsiella pneumoniae ESBL and 1 isolate of Klebsiella oxytoca ESBL. The "in house" test offers the following values: sensitivity 98% and specificity 97%, with negative predictive value 100% and positive predictive value 78%. The "in house" test based on the change of pH is useful in our area for detecting presumptively cefotaxime-resistant Enterobacteriaceae strains. Copyright © 2016 Asociación Argentina de Microbiología. Publicado por Elsevier España, S.L.U. All rights reserved.

  11. Tabhu: tools for antibody humanization.

    KAUST Repository

    Olimpieri, Pier Paolo

    2014-10-09

    SUMMARY: Antibodies are rapidly becoming essential tools in the clinical practice, given their ability to recognize their cognate antigens with high specificity and affinity, and a high yield at reasonable costs in model animals. Unfortunately, when administered to human patients, xenogeneic antibodies can elicit unwanted and dangerous immunogenic responses. Antibody humanization methods are designed to produce molecules with a better safety profile still maintaining their ability to bind the antigen. This can be accomplished by grafting the non-human regions determining the antigen specificity into a suitable human template. Unfortunately, this procedure may results in a partial or complete loss of affinity of the grafted molecule that can be restored by back-mutating some of the residues of human origin to the corresponding murine ones. This trial-and-error procedure is hard and involves expensive and time-consuming experiments. Here we present tools for antibody humanization (Tabhu) a web server for antibody humanization. Tabhu includes tools for human template selection, grafting, back-mutation evaluation, antibody modelling and structural analysis, helping the user in all the critical steps of the humanization experiment protocol. AVAILABILITY: http://www.biocomputing.it/tabhu CONTACT: anna.tramontano@uniroma1.it, pierpaolo.olimpieri@uniroma1.it SUPPLEMENTARY INFORMATION: Supplementary data are available at Bioinformatics online.

  12. Bioconjugated fluorescent silica nanoparticles for the rapid detection of Entamoeba histolytica.

    Science.gov (United States)

    Hemadi, Ahmad; Ekrami, Alireza; Oormazdi, Hormozd; Meamar, Ahmad Reza; Akhlaghi, Lame; Samarbaf-Zadeh, Ali Reza; Razmjou, Elham

    2015-05-01

    Rapid detection of Entamoeba histolytica based on fluorescent silica nanoparticle (FSNP) indirect immunofluorescence microscopy was evaluated. Silica nanoparticles were synthesized using Stöber's method, with their surface activated to covalently bind to, and immobilize, protein A. For biolabeling, FSNP was added to conjugated E. histolytica trophozoites with monoclonal anti-E. histolytica IgG1 for microscopic observation of fluorescence. Fluorescent silica nanoparticle sensitivity was determined with axenically cultured E. histolytica serially diluted to seven concentrations. Specificity was evaluated using other intestinal protozoa. Fluorescent silica nanoparticles detected E. histolytica at the lowest tested concentration with no cross-reaction with Entamoeba dispar, Entamoeba moshkovskii, Blastocystis sp., or Giardia lamblia. Visualization of E. histolytica trophozoites with anti-E. histolytica antibody labeled with fluorescein isothiocyanate (FITC) was compared with that using anti-E. histolytica antibody bioconjugated FSNP. Although FITC and FSNP produced similar results, the amount of specific antibody required for FITC to induce fluorescence of similar intensity was fivefold that for FSNP. Fluorescent silica nanoparticles delivered a rapid, simple, cost-effective, and highly sensitive and specific method of detecting E. histolytica. Further study is needed before introducing FSNP for laboratory diagnosis of amoebiasis. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Viral hepatitis and rapid diagnostic test based screening for HBsAg in HIV-infected patients in rural Tanzania.

    Directory of Open Access Journals (Sweden)

    Fabian C Franzeck

    Full Text Available BACKGROUND: Co-infection with hepatitis B virus (HBV is highly prevalent in people living with HIV in Sub-Saharan Africa. Screening for HBV surface antigen (HBsAg before initiation of combination antiretroviral therapy (cART is recommended. However, it is not part of diagnostic routines in HIV programs in many resource-limited countries although patients could benefit from optimized antiretroviral therapy covering both infections. Screening could be facilitated by rapid diagnostic tests for HBsAg. Operating experience with these point of care devices in HIV-positive patients in Sub-Saharan Africa is largely lacking. We determined the prevalence of HBV and Hepatitis C virus (HCV infection as well as the diagnostic accuracy of the rapid test device Determine HBsAg in an HIV cohort in rural Tanzania. METHODS: Prospectively collected blood samples from adult, HIV-1 positive and antiretroviral treatment-naïve patients in the Kilombero and Ulanga antiretroviral cohort (KIULARCO in rural Tanzania were analyzed at the point of care with Determine HBsAg, a reference HBsAg EIA and an anti-HCV EIA. RESULTS: Samples of 272 patients were included. Median age was 38 years (interquartile range [IQR] 32-47, 169/272 (63% subjects were females and median CD4+ count was 250 cells/µL (IQR 97-439. HBsAg was detected in 25/272 (9.2%, 95% confidence interval [CI] 6.2-13.0% subjects. Of these, 7/25 (28% were positive for HBeAg. Sensitivity of Determine HBsAg was rated at 96% (95% CI 82.8-99.6% and specificity at 100% (95% CI, 98.9-100%. Antibodies to HCV (anti-HCV were found in 10/272 (3.7%, 95% CI 2.0-6.4% of patients. CONCLUSION: This study reports a high prevalence of HBV in HIV-positive patients in a rural Tanzanian setting. The rapid diagnostic test Determine HBsAg is an accurate assay for screening for HBsAg in HIV-1 infected patients at the point of care and may further help to guide cART in Sub-Saharan Africa.

  14. Immunochromatographic Brucella-specific immunoglobulin M and G lateral flow assays for rapid serodiagnosis of human brucellosis

    NARCIS (Netherlands)

    Smits, Henk L.; Abdoel, Theresia H.; Solera, Javier; Clavijo, Encarnacion; Diaz, Ramon

    2003-01-01

    To fulfill the need for a simple and rapid diagnostic test for human brucellosis, we used the immunochromatographic lateral flow assay format to develop two assays, one for the detection of Brucella-specific immunoglobulin M (IgM) antibodies and one for the detection of Brucella-specific IgG

  15. Screening Yield of HIV Antigen/Antibody Combination and Pooled HIV RNA Testing for Acute HIV Infection in a High-Prevalence Population.

    Science.gov (United States)

    Peters, Philip J; Westheimer, Emily; Cohen, Stephanie; Hightow-Weidman, Lisa B; Moss, Nicholas; Tsoi, Benjamin; Hall, Laura; Fann, Charles; Daskalakis, Demetre C; Beagle, Steve; Patel, Pragna; Radix, Asa; Foust, Evelyn; Kohn, Robert P; Marmorino, Jenni; Pandori, Mark; Fu, Jie; Samandari, Taraz; Gay, Cynthia L

    2016-02-16

    Although acute HIV infection contributes disproportionately to onward HIV transmission, HIV testing has not routinely included screening for acute HIV infection. To evaluate the performance of an HIV antigen/antibody (Ag/Ab) combination assay to detect acute HIV infection compared with pooled HIV RNA testing. Multisite, prospective, within-individual comparison study conducted between September 2011 and October 2013 in 7 sexually transmitted infection clinics and 5 community-based programs in New York, California, and North Carolina. Participants were 12 years or older and seeking HIV testing, without known HIV infection. All participants with a negative rapid HIV test result were screened for acute HIV infection with an HIV Ag/Ab combination assay (index test) and pooled human immunodeficiency virus 1 (HIV-1) RNA testing. HIV RNA testing was the reference standard, with positive reference standard result defined as detectable HIV-1 RNA on an individual RNA test. Number and proportion with acute HIV infections detected. Among 86,836 participants with complete test results (median age, 29 years; 75.0% men; 51.8% men who have sex with men), established HIV infection was diagnosed in 1158 participants (1.33%) and acute HIV infection was diagnosed in 168 participants (0.19%). Acute HIV infection was detected in 134 participants with HIV Ag/Ab combination testing (0.15% [95% CI, 0.13%-0.18%]; sensitivity, 79.8% [95% CI, 72.9%-85.6%]; specificity, 99.9% [95% CI, 99.9%-99.9%]; positive predictive value, 59.0% [95% CI, 52.3%-65.5%]) and in 164 participants with pooled HIV RNA testing (0.19% [95% CI, 0.16%-0.22%]; sensitivity, 97.6% [95% CI, 94.0%-99.4%]; specificity, 100% [95% CI, 100%-100%]; positive predictive value, 96.5% [95% CI, 92.5%-98.7%]; sensitivity comparison, P testing detected 82% of acute HIV infections detectable by pooled HIV RNA testing. Compared with rapid HIV testing alone, HIV Ag/Ab combination testing increased the relative HIV diagnostic yield (both

  16. Intramuscular Immunisation with Chlamydial Proteins Induces Chlamydia trachomatis Specific Ocular Antibodies.

    Directory of Open Access Journals (Sweden)

    Alexander Badamchi-Zadeh

    Full Text Available Ocular infection with Chlamydia trachomatis can cause trachoma, which is the leading cause of blindness due to infection worldwide. Despite the large-scale implementation of trachoma control programmes in the majority of countries where trachoma is endemic, there remains a need for a vaccine. Since C. trachomatis infects the conjunctival epithelium and stimulates an immune response in the associated lymphoid tissue, vaccine regimens that enhance local antibody responses could be advantageous. In experimental infections of non-human primates (NHPs, antibody specificity to C. trachomatis antigens was found to change over the course of ocular infection. The appearance of major outer membrane protein (MOMP specific antibodies correlated with a reduction in ocular chlamydial burden, while subsequent generation of antibodies specific for PmpD and Pgp3 correlated with C. trachomatis eradication.We used a range of heterologous prime-boost vaccinations with DNA, Adenovirus, modified vaccinia Ankara (MVA and protein vaccines based on the major outer membrane protein (MOMP as an antigen, and investigated the effect of vaccine route, antigen and regimen on the induction of anti-chlamydial antibodies detectable in the ocular lavage fluid of mice.Three intramuscular vaccinations with recombinant protein adjuvanted with MF59 induced significantly greater levels of anti-MOMP ocular antibodies than the other regimens tested. Intranasal delivery of vaccines induced less IgG antibody in the eye than intramuscular delivery. The inclusion of the antigens PmpD and Pgp3, singly or in combination, induced ocular antigen-specific IgG antibodies, although the anti-PmpD antibody response was consistently lower and attenuated by combination with other antigens.If translatable to NHPs and/or humans, this investigation of the murine C. trachomatis specific ocular antibody response following vaccination provides a potential mouse model for the rapid and high throughput

  17. 42 CFR 493.865 - Standard; Antibody identification.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Standard; Antibody identification. 493.865 Section..., Or Any Combination of These Tests § 493.865 Standard; Antibody identification. (a) Failure to attain... proficiency testing event. (e) Failure to identify the same antibody in two consecutive or two out of three...

  18. Biconically Tapered Fiber Optic Probes for Rapid Label-Free Immunoassays

    Directory of Open Access Journals (Sweden)

    John Miller

    2015-04-01

    Full Text Available We report use of U-shaped biconically tapered optical fibers (BTOF as probes for label-free immunoassays. The tapered regions of the sensors were functionalized by immobilization of immunoglobulin-G (Ig-G and tested for detection of anti-IgG at concentrations of 50 ng/mL to 50 µg/mL. Antibody-antigen reaction creates a biological nanolayer modifying the waveguide structure leading to a change in the sensor signal, which allows real-time monitoring. The kinetics of the antibody (mouse Ig-G-antigen (rabbit anti-mouse IgG reactions was studied. Hydrofluoric acid treatment makes the sensitive region thinner to enhance sensitivity, which we confirmed by experiments and simulations. The limit of detection for the sensor was estimated to be less than 50 ng/mL. Utilization of the rate of the sensor peak shift within the first few minutes of the antibody-antigen reaction is proposed as a rapid protein detection method.

  19. Evaluation of the OnSite malaria rapid test performance in Miandrivazo, Madagascar.

    Science.gov (United States)

    Ravaoarisoa, E; Andriamiandranoro, T; Raherinjafy, R; Jahevitra, M; Razanatsiorimalala, S; Andrianaranjaka, V; Randrianarivelojosia, M

    2017-10-01

    The performance of the malaria rapid diagnostic test OnSite-for detecting pan specific pLDH and Plasmodium falciparum specific HRP2 - was assessed during the malaria transmission peak period in Miandrivazo, in the southwestern part of Madagascar from April 20 to May 6, 2010. At the laboratory, the quality control OnSite Malaria Rapid Test according to the WHO/TDR/FIND method demonstrated that the test had good sensitivity. Of the 218 OnSite tests performed at the Miandrivazo Primary Health Center on patients with fever or a recent history of fever, four (1.8%, 95% CI: 0.6-4.9%) were invalid. Ninety four (43,1%) cases of malaria were confirmed by microscopy, of which 90 were P. falciparum malaria and 4 Plasmodium vivax malaria. With a Cohen's kappa coefficient of 0.94, the agreement between microscopy and OnSite is excellent. Compared with the rapid test CareStart™ commonly used within the public health structures in Madagascar, the sensitivity and specificity of the OnSite test were 97.9% and 96.8%.

  20. Towards Universal Screening for Toxoplasmosis: Rapid, Cost-effective and Simultaneous Detection of Toxoplasma Anti-IgG, IgM and IgA Antibodies Using Very Small Serum Volumes

    Science.gov (United States)

    No dataset associated with this publication.This dataset is associated with the following publication:Augustine, S. Towards Universal Screening for Toxoplasmosis: Rapid, Cost-effective and Simultaneous Detection of Toxoplasma Anti-IgG, IgM and IgA Antibodies Using Very Small Serum Volumes. JOURNAL OF CLINICAL MICROBIOLOGY. American Society for Microbiology, Washington, DC, USA, 56(7): 1-2, (2016).

  1. Immunoglobulin G antibodies against deamidated-gliadin-peptides outperform anti-endomysium and tissue transglutaminase antibodies in children

    NARCIS (Netherlands)

    Mubarak, A.; Gmelig-Meyling, F. H. J.; Wolters, V. M.; ten Kate, F. J. W.; Houwen, R. H. J.

    2011-01-01

    To investigate the usefulness of deamidated-gliadin-peptides-antibodies in the diagnosis of celiac disease, serology was tested in 212 children suspected with celiac disease who had undergone a small-intestinal-biopsy. For deamidated-gliadin-peptides-antibodies, two kits were tested. Positive and

  2. Lateral flow test strip based on colloidal selenium immunoassay for rapid detection of melamine in milk, milk powder, and animal feed

    Directory of Open Access Journals (Sweden)

    Wang ZZ

    2014-04-01

    Full Text Available Zhizeng Wang,1 Dejuan Zhi,2 Yang Zhao,1 Hailong Zhang,2 Xin Wang,2 Yi Ru,1 Hongyu Li1,2 1MOE Key Laboratory of Cell Activities and Stress Adaptations, School of Life Sciences, Lanzhou University, Lanzhou, People's Republic of China; 2Institute of Microbiology and Biochemical Pharmacy, School of Pharmaceutics, Lanzhou University, Lanzhou, People's Republic of China Abstract: Although high melamine (MEL intake has been proven to cause serious health problems, MEL is sometimes illegally added to milk products and animal feed, arousing serious food safety concerns. A satisfactory method of detecting MEL in onsite or in-home testing is in urgent need of development. This work aimed to explore a rapid, convenient, and cost-effective method of identifying MEL in milk products or other food by colloidal selenium-based lateral flow immunoassay. Colloidal selenium was synthesized by L-ascorbic acid to reduce seleninic acid at room temperature. After conjugation with a monoclonal antibody anti-MEL, a test strip was successfully prepared. The detection limit of the test strip reached 150 µg/kg, 1,000 µg/kg, and 800 µg/kg in liquid milk, milk powder, and animal feed, respectively. No cross-reactions with homologues cyanuric acid, cyanurodiamide, or ammelide were found. Moreover, the MEL test strip can remain stable after storage for 1 year at room temperature. Our results demonstrate that the colloidal selenium MEL test strip can detect MEL in adulterated milk products or animal feed conveniently, rapidly, and sensitively. In contrast with a colloidal gold MEL test strip, the colloidal selenium MEL test strip was easy to prepare and more cost-efficient. Keywords: melamine, selenium nanoparticles, test strip, milk, animal feed, dairy food

  3. SU-E-I-14: Comparison of Iodine-Labeled and Indium-Labeled Antibody Biodistributions

    Energy Technology Data Exchange (ETDEWEB)

    Williams, L [Retired from City of Hope Medical Center, Arcadia, CA (United States)

    2014-06-01

    Purpose: It is often assumed that animal biodistributions of novel proteins are not dependent upon the radiolabel used in their determination. In units of percent injected dose per gram of tissue (%ID/g), organ uptake results (u) may be obtained using either iodine or metal as radioactive labels. Iodination is preferred as it is a one-step process whereas metal labeling requires two chemical procedures and therefore more protein material. It is important to test whether the radioactive tag leads to variation in the uptake value. Methods: Uptakes of 3antibodies to Carcinoembryonic Antigen (CEA) were evaluated in a nude mouse model bearing 150 to 300 mg LS174T human colon cancer xenografts. Antibodies included diabody (56 kDa), minibody (80kDa) and intact M5A (150 kDa) anti-CEA cognates. Both radioiodine and indium-111 labels were used with uptakes evaluated at 7 time(t) points out to 96 h. Ratios (R) of u(iodine-label)/u(indium-label) were determined for liver, spleen, kidneys, lung and tumor. Results: Hepatic loss was rapid for diabody and minibody; by 24 h their R values were only 2%; i.e., uptake of iodine was 2% of that of indium for these 2 antibodies. By contrast, R for the intact cognate was 50% at that time point. Splenic results were similar. Tumor uptake ratios did not depend upon the antibody type and were 50% at 24 h. Conclusions: Relatively rapid loss of iodine relative to indium in liver and spleen was observed in lower mass antibodies. Tumor ratios were larger and independent of antibody type. Aside from tumor, the R ratio of uptakes depended on the antibody type. R values decreased monotonically with time in all tissues and for all cognates. Using this ratio, one can possibly correct iodine-based u (t) results so that they resemble radiometal-derived biodistributions.

  4. Interlaboratory testing of porcine sera for antibodies to porcine circovirus type 2

    DEFF Research Database (Denmark)

    McNair, I.; Marshall, M.; McNeilly, F.

    2004-01-01

    A panel of 20 porcine sera was distributed to 5 laboratories across Europe and Canada. Each center was requested to test the sera for the presence of porcine circovirus type 2 antibodies using the routine assays, indirect immunofluorescence assay (IFA) and indirect immunoperoxidase monolayer assa...... than did IFA, and paraformaldehyde gave higher titers than did acetone or ethyl alcohol. This report highlights the need for standardized procedures and biologicals for this virus....

  5. Rapid analysis of charge variants of monoclonal antibodies using non-linear salt gradient in cation-exchange high performance liquid chromatography.

    Science.gov (United States)

    Joshi, Varsha; Kumar, Vijesh; Rathore, Anurag S

    2015-08-07

    A method is proposed for rapid development of a short, analytical cation exchange high performance liquid chromatography method for analysis of charge heterogeneity in monoclonal antibody products. The parameters investigated and optimized include pH, shape of elution gradient and length of the column. It is found that the most important parameter for development of a shorter method is the choice of the shape of elution gradient. In this paper, we propose a step by step approach to develop a non-linear sigmoidal shape gradient for analysis of charge heterogeneity for two different monoclonal antibody products. The use of this gradient not only decreases the run time of the method to 4min against the conventional method that takes more than 40min but also the resolution is retained. Superiority of the phosphate gradient over sodium chloride gradient for elution of mAbs is also observed. The method has been successfully evaluated for specificity, sensitivity, linearity, limit of detection, and limit of quantification. Application of this method as a potential at-line process analytical technology tool has been suggested. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Application and Comparative Evaluation of Fluorescent Antibody, Immunohistochemistry and Reverse Transcription Polymerase Chain Reaction Tests for the Detection of Rabies Virus Antigen or Nucleic Acid in Brain Samples of Animals Suspected of Rabies in India

    Directory of Open Access Journals (Sweden)

    K. Nithin Prabhu

    2018-02-01

    Full Text Available Accurate and early diagnosis of animal rabies is critical for undertaking public health measures. Whereas the direct fluorescent antibody (DFA technique is the recommended test, the more convenient, direct rapid immunochemistry test (dRIT, as well as the more sensitive, reverse transcription polymerase chain reaction (RT-PCR, have recently been employed for the laboratory diagnosis of rabies. We compared the three methods on brain samples from domestic (dog, cat, cattle, buffalo, horse, pig and goat and wild (leopard, wolf and jackal animals from various parts of India. Of the 257 samples tested, 167 were positive by all the three tests; in addition, 35 of the 36 decomposed samples were positive by RT-PCR. This is the first study in which such large number of animal samples have been subjected to the three tests simultaneously. The results confirm 100% corroboration between DFA and dRIT, buttress the applicability of dRIT in the simple and rapid diagnosis of rabies in animals, and reaffirm the suitability of RT-PCR for samples unfit for testing either by DFA or dRIT.

  7. Application and Comparative Evaluation of Fluorescent Antibody, Immunohistochemistry and Reverse Transcription Polymerase Chain Reaction Tests for the Detection of Rabies Virus Antigen or Nucleic Acid in Brain Samples of Animals Suspected of Rabies in India.

    Science.gov (United States)

    Prabhu, K Nithin; Isloor, Shrikrishna; Veeresh, B Hanchinal; Rathnamma, Doddamane; Sharada, R; Das, Lekshmi J; Satyanarayana, M L; Hegde, Nagendra R; Rahman, Sira Abdul

    2018-02-28

    Accurate and early diagnosis of animal rabies is critical for undertaking public health measures. Whereas the direct fluorescent antibody (DFA) technique is the recommended test, the more convenient, direct rapid immunochemistry test (dRIT), as well as the more sensitive, reverse transcription polymerase chain reaction (RT-PCR), have recently been employed for the laboratory diagnosis of rabies. We compared the three methods on brain samples from domestic (dog, cat, cattle, buffalo, horse, pig and goat) and wild (leopard, wolf and jackal) animals from various parts of India. Of the 257 samples tested, 167 were positive by all the three tests; in addition, 35 of the 36 decomposed samples were positive by RT-PCR. This is the first study in which such large number of animal samples have been subjected to the three tests simultaneously. The results confirm 100% corroboration between DFA and dRIT, buttress the applicability of dRIT in the simple and rapid diagnosis of rabies in animals, and reaffirm the suitability of RT-PCR for samples unfit for testing either by DFA or dRIT.

  8. Evaluation of the Acridine Orange Fluorescence Technique and the Indirect Fluorescent Antibody as Diagnostic Tests for Tropical Theileriosis

    Directory of Open Access Journals (Sweden)

    Mahmoud

    2011-06-01

    Full Text Available This study was carried out to evaluate the use of acridine orange fluorescence technique on blood slides as a rapid diagnostic test for tropical theileriosis in comparison with the Giemsa-stained thin blood film technique. Also the indirect fluorescent antibody test has been employed for the serodiagnosis of tropical theileriosis. The study was carried out on 62 young and 48 adult Friesian cattle suffering from clinical tropical theileriosis in Qassim Region, Central Saudi Arabia, during the period from August 2006 to July 2008. For control, blood samples were also obtained from 25 young and 25 adult, clinically healthy, Friesian cattle, selected at random from different dairy farms in Qassim Region. Thin blood films were fixed with methanol and stained with Giemsa and acridine orange and were examined by two independent microbiologists. There was 100% correlation in the interpretation of slides stained with Giemsa and acridine orange both with respect to positivity and negativity, between the two microbiologists. It is concluded that if facilities are available acridine orange is a valuable alternative for screening tropical theileriosis. The method may also have potential value in the diagnosis of Theileria parva, which causes East Coast fever, and also other Theileria species. Results of the present study also showed that IFA test was not found sufficiently sensitive and specific as has been reported earlier. [Vet. World 2011; 4(8.000: 341-344

  9. Ausab test - a radioimmunoassay in the solid phase for the detection of antibodies against HBsAg

    Energy Technology Data Exchange (ETDEWEB)

    Lange, W; Koehler, H; Apodaca, J [Bundesgesundheitsamt, Berlin (Germany, F.R.). Abt. fuer Virologie

    1974-01-01

    The suitability of a newly developed RIA (Ausab test, Abbott laboratories) for the detection of antibodies against the Hepatitis B (surface) antigen (HBsAg) has been tested on 1968 sera of blood donors. Reproducibility test and specificity test were included. During the examination the technique of the Ausab test was changed from the original one-step to the two-step procedure. With the one-step technique 431 of 1968 sera (21.9%) showed positive reactions. During the test problems concerning the differentiation between positive and negative results were encountered due to high unspecific binding of radioactivity. Positive sera were re-examined employing the two-step technique and only 77.4% of the previously positive reactions could be reproduced. 50 sera that were negative in the one-step test remained negative in the two-step test. Difficulties concerning nonspecific binding of radioactivity as observed with the one-step technique were not encountered with the two-step procedure. On 92 of the confirmed positive sera a specificity test was run and 90 (97.8%) proved to be specific. A calculated 16.5% of the blood donors in Berlin have to be considered as antibody carriers. Only 6 of the Ausab positive sera were found to give positive reactions in CEP. 3 sera that were initially positive in CEP could neither be confirmed in a repeated CEP nor in the Ausab test.

  10. Antibodies to poliovirus detected by immunoradiometric assay with a monoclonal antibody

    International Nuclear Information System (INIS)

    Spitz, M.; Fossati, C.A.; Schild, G.C.; Spitz, L.; Brasher, M.

    1982-01-01

    An immunoradiometric assay (IRMA) for the assay of antibodies to poliovirus antigens is described. Dilutions of the test sera or whole (finger prick) blood samples were incubated with the poliovirus antigen bound to a solid phase and the specific antibody was detected by the addition of a mouse anti-human IgG monoclonal antibody (McAb), which was itself revealed by iodinated sheep IgG antimouse F(ab). The authors have shown that this technique is suitable for the estimation of IgG anti-poliovirus antibodies induced in children following polio vaccine. The present study shows that SPRIA provides a simple and inexpensive method for serological studies with poliovirus particularly for use in large-scale surveys. (Auth.)

  11. Antibodies to poliovirus detected by immunoradiometric assay with a monoclonal antibody

    Energy Technology Data Exchange (ETDEWEB)

    Spitz, M.; Fossati, C.A.; Schild, G.C.; Spitz, L.; Brasher, M. (National Inst. for Biological Standards and Control, London (UK))

    1982-10-01

    An immunoradiometric assay (IRMA) for the assay of antibodies to poliovirus antigens is described. Dilutions of the test sera or whole (finger prick) blood samples were incubated with the poliovirus antigen bound to a solid phase and the specific antibody was detected by the addition of a mouse anti-human IgG monoclonal antibody (McAb), which was itself revealed by iodinated sheep IgG antimouse F(ab). The authors have shown that this technique is suitable for the estimation of IgG anti-poliovirus antibodies induced in children following polio vaccine. The present study shows that SPRIA provides a simple and inexpensive method for serological studies with poliovirus particularly for use in large-scale surveys.

  12. Development and evaluation of a magnetic immunochromatographic test to detect Taenia solium, which causes taeniasis and neurocysticercosis in humans.

    Science.gov (United States)

    Handali, Sukwan; Klarman, Molly; Gaspard, Amanda N; Dong, X Fan; Laborde, Ronald; Noh, John; Lee, Yeuk-Mui; Rodriguez, Silvia; Gonzalez, Armando E; Garcia, Hector H; Gilman, Robert H; Tsang, Victor C W; Wilkins, Patricia P

    2010-04-01

    Taeniasis/cysticercosis caused by Taenia solium is a frequent parasitic infection of the human brain in most of the world. Rapid and simple screening tools to identify taeniasis and cysticercosis cases are needed for control programs, mostly to identify tapeworm carriers which are the source of infection and need to be treated, or as tools for point-of-care case detection or confirmation. These screening assays should be affordable, reliable, rapid, and easy to perform. Immunochromatographic tests meet these criteria. To demonstrate proof of principle, we developed and evaluated two magnetic immunochromatographic tests (MICTs) for detection of human Taenia solium taeniasis antibodies (ES33-MICT) and neurocysticercosis antibodies (T24-MICT). These assays detected stage-specific antibodies by using two recombinant proteins, rES33 for detection of taeniasis antibodies and rT24H for detection of cysticercosis antibodies. The sensitivity and specificity of the ES33-MICT to detect taeniasis infections were 94.5% and 96%, respectively, and those of the T24-MICT to detect cases of human cysticercosis with two or more viable brain cysts were 93.9% and 98.9%, respectively. These data provide proof of principle that the ES33- and T24-MICTs provide rapid and suitable methods to identify individuals with taeniasis and cysticercosis.

  13. Development and Evaluation of a Magnetic Immunochromatographic Test To Detect Taenia solium, Which Causes Taeniasis and Neurocysticercosis in Humans▿

    Science.gov (United States)

    Handali, Sukwan; Klarman, Molly; Gaspard, Amanda N.; Dong, X. Fan; LaBorde, Ronald; Noh, John; Lee, Yeuk-Mui; Rodriguez, Silvia; Gonzalez, Armando E.; Garcia, Hector H.; Gilman, Robert H.; Tsang, Victor C. W.; Wilkins, Patricia P.

    2010-01-01

    Taeniasis/cysticercosis caused by Taenia solium is a frequent parasitic infection of the human brain in most of the world. Rapid and simple screening tools to identify taeniasis and cysticercosis cases are needed for control programs, mostly to identify tapeworm carriers which are the source of infection and need to be treated, or as tools for point-of-care case detection or confirmation. These screening assays should be affordable, reliable, rapid, and easy to perform. Immunochromatographic tests meet these criteria. To demonstrate proof of principle, we developed and evaluated two magnetic immunochromatographic tests (MICTs) for detection of human Taenia solium taeniasis antibodies (ES33-MICT) and neurocysticercosis antibodies (T24-MICT). These assays detected stage-specific antibodies by using two recombinant proteins, rES33 for detection of taeniasis antibodies and rT24H for detection of cysticercosis antibodies. The sensitivity and specificity of the ES33-MICT to detect taeniasis infections were 94.5% and 96%, respectively, and those of the T24-MICT to detect cases of human cysticercosis with two or more viable brain cysts were 93.9% and 98.9%, respectively. These data provide proof of principle that the ES33- and T24-MICTs provide rapid and suitable methods to identify individuals with taeniasis and cysticercosis. PMID:20181766

  14. An ELISA to Detect Serum Antibodies to the Salivary Gland Toxin of Ixodes holocyclus Neumann in Dogs and Rodents

    Directory of Open Access Journals (Sweden)

    S. Hall-Mendelin

    2011-01-01

    Full Text Available The Ixodes holocyclus tick causes paralysis in up to 10,000 companion and domestic animals each year in Australia. Treatment requires the removal of the parasite and the administration of a commercial tick antiserum that is prepared from hyperimmune dogs. Each batch of this serum is initially tested for toxin-neutralising potency in a mouse bioassay that is expensive, time consuming, and subjective. With the aim of developing a rapid in vitro assay to replace the bioassay, we used a partially purified antigen prepared from I. holocyclus salivary glands to develop an ELISA to detect toxin-reactive antibodies in hyperimmune dog sera. The optimised ELISA reliably detected antibodies reactive to I. holocyclus salivary gland antigens. Parallel testing of sera with a negative control antigen prepared from the salivary glands of the nontoxic tick Rhipicephalus (Boophilus microplus provided further evidence that we were detecting toxin-specific antibodies in the assay. Using the ELISA, we could also detect antibodies induced in rats after experimental infestation with I. holocyclus. This assay shows promise as an alternative means of assessing the potency of batches of hyperimmune dog serum and to screen for toxin-reactive monoclonal antibodies produced from immunised rodents.

  15. Immunochromatographic Strip Test for Rapid Detection of Diphtheria Toxin: Description and Multicenter Evaluation in Areas of Low and High Prevalence of Diphtheria

    Science.gov (United States)

    Engler, K. H.; Efstratiou, A.; Norn, D.; Kozlov, R. S.; Selga, I.; Glushkevich, T. G.; Tam, M.; Melnikov, V. G.; Mazurova, I. K.; Kim, V. E.; Tseneva, G. Y.; Titov, L. P.; George, R. C.

    2002-01-01

    An immunochromatographic strip (ICS) test was developed for the detection of diphtheria toxin by using an equine polyclonal antibody as the capture antibody and colloidal gold-labeled monoclonal antibodies specific for fragment A of the diphtheria toxin molecule as the detection antibody. The ICS test has been fully optimized for the detection of toxin from bacterial cultures; the limit of detection was approximately 0.5 ng of diphtheria toxin per ml within 10 min. In a comparative study with 915 pure clinical isolates of Corynebacterium spp., the results of the ICS test were in complete agreement with those of the conventional Elek test. The ICS test was also evaluated for its ability to detect toxigenicity from clinical specimens (throat swabs) in two field studies conducted within areas of the former USSR where diphtheria is epidemic. Eight hundred fifty throat swabs were examined by conventional culture and by use of directly inoculated broth cultures for the ICS test. The results showed 99% concordance (848 of 850 specimens), and the sensitivity and specificity of the ICS test were 98% (95% confidence interval, 91 to 99%) and 99% (95% confidence interval, 99 to 100%), respectively. PMID:11773096

  16. Analysis of the theoretical model of the rapid chloride migration test

    NARCIS (Netherlands)

    Spiesz, P.; Brouwers, H.J.H.; Fisher, Gregor; Geiker, Metta Rica; Hededal, Ole; Ottosen, Lisbeth M.; Stang, Henrik

    2010-01-01

    Chloride ion diffusion coefficient in concrete is estimated very often by using electromigration tests, among which the Rapid Chloride Migration (RCM) test is becoming more and more popular. Nevertheless, this test receives much criticism due to lacks in its scientific background. In this paper the

  17. The cost of implementing rapid HIV testing in sexually transmitted disease clinics in the United States.

    Science.gov (United States)

    Eggman, Ashley A; Feaster, Daniel J; Leff, Jared A; Golden, Matthew R; Castellon, Pedro C; Gooden, Lauren; Matheson, Tim; Colfax, Grant N; Metsch, Lisa R; Schackman, Bruce R

    2014-09-01

    Rapid HIV testing in high-risk populations can increase the number of persons who learn their HIV status and avoid spending clinic resources to locate persons identified as HIV infected. We determined the cost to sexually transmitted disease (STD) clinics of point-of-care rapid HIV testing using data from 7 public clinics that participated in a randomized trial of rapid testing with and without brief patient-centered risk reduction counseling in 2010. Costs included counselor and trainer time, supplies, and clinic overhead. We applied national labor rates and test costs. We calculated median clinic start-up costs and mean cost per patient tested, and projected incremental annual costs of implementing universal rapid HIV testing compared with current testing practices. Criteria for offering rapid HIV testing and methods for delivering nonrapid test results varied among clinics before the trial. Rapid HIV testing cost an average of US $22/patient without brief risk reduction counseling and US $46/patient with counseling in these 7 clinics. Median start-up costs per clinic were US $1100 and US $16,100 without and with counseling, respectively. Estimated incremental annual costs per clinic of implementing universal rapid HIV testing varied by whether or not brief counseling is conducted and by current clinic testing practices, ranging from a savings of US $19,500 to a cost of US $40,700 without counseling and a cost of US $98,000 to US $153,900 with counseling. Universal rapid HIV testing in STD clinics with same-day results can be implemented at relatively low cost to STD clinics, if brief risk reduction counseling is not offered.

  18. Complexes of DNA with fluorescent dyes are effective reagents for detection of autoimmune antibodies

    DEFF Research Database (Denmark)

    Domljanovic, Ivana; Carstens, Annika; Okholm, Anders

    2017-01-01

    as targets for these antibodies. This is done in a simple, rapid and specific immunofluorescence assay. Specifically, employing 3D nanostructures (DNA origami), we present a new approach in the detection and study of human antibodies to DNA. We demonstrate the detection of anti-DNA antibodies...

  19. Improving prescribing practices with rapid diagnostic tests (RDTs)

    DEFF Research Database (Denmark)

    Burchett, Helen E D; Leurent, Baptiste; Baiden, Frank

    2017-01-01

    OBJECTIVES: The overuse of antimalarial drugs is widespread. Effective methods to improve prescribing practice remain unclear. We evaluated the impact of 10 interventions that introduced rapid diagnostic tests for malaria (mRDTs) on the use of tests and adherence to results in different contexts...... packages, supervision, supplies and community sensitisation. OUTCOME MEASURES: Analysis explored variation in: (1) uptake of mRDTs (% febrile patients tested); (2) provider adherence to positive mRDTs (% Plasmodium falciparum positive prescribed/given Artemisinin Combination Treatment); (3) provider...... characteristics fitted with their own priorities. Goodness of fit of mRDTs with existing consultation and diagnostic practices appeared crucial to maximising the impact of mRDTs on care, as did prior familiarity with malaria testing; adequate human resources and supplies; possible alternative treatments for m...

  20. Improving the screening of blood donors with syphilis rapid diagnostic test (RDT) and rapid plasma reagin (RPR) in low- and middle-income countries (LMIC)

    DEFF Research Database (Denmark)

    Sarkodie, F.; Hassall, O.; Owusu-Dabo, E.

    2017-01-01

    BACKGROUND: Syphilis testing conventionally relies on a combination of non-treponemal and treponemal tests. The primary objective of this study was to describe the positive predictive value (PPV) of a screening algorithm in a combination of a treponemal rapid diagnostic test (RDT) and rapid plasma...

  1. Comparative evaluation of blood and serum samples in rapid immunochromatographic tests for visceral leishmaniasis.

    Science.gov (United States)

    Kumar, Dinesh; Khanal, Basudha; Tiwary, Puja; Mudavath, Shyam Lal; Tiwary, Narendra K; Singh, Rupa; Koirala, Kanika; Boelaert, Marleen; Rijal, Suman; Sundar, Shyam

    2013-12-01

    Rapid diagnostic tests (RDTs) based on the detection of specific antibodies in serum are commonly used for the diagnosis of visceral leishmaniasis (VL). Several commercial kits are available, and some of them allow the use of whole-blood samples instead of serum. An RDT is much more user-friendly for blood samples than for serum samples. In this study, we examined the sensitivities and specificities of six different commercially available immunochromatographic tests for their accuracy in detecting Leishmania infection in whole blood and serum of parasitologically confirmed VL cases. This study was performed in areas of India and Nepal where VL is endemic. A total of 177 confirmed VL cases, 208 healthy controls from areas of endemicity (EHCs), 26 malaria patients (MP), and 37 tuberculosis (TB) patients were enrolled. The reproducibilities of the blood and serum results and between-reader and between-laboratory results were tested. In India, the sensitivities of all the RDTs ranged between 94.7 and 100.0%, with no significant differences between whole blood and serum. The specificities ranged between 92.4 and 100.0%, except for the specificity of the Onsite Leishmania Ab RevB kit, which was lower (33.6 to 42.0%). No differences in specificities were observed for blood and serum. In Nepal, the sensitivities of all the test kits, for whole-blood as well as serum samples, ranged between 96.3 and 100.0%, and the specificities ranged between 90.1 and 96.1%, again with the exception of that of the Onsite Leishmania Ab RevB test, which was markedly lower (48.7 to 49.3%). The diagnostic accuracies of all the tests, except for one brand, were excellent for the whole-blood and serum samples. We conclude that whole blood is an adequate alternative for serum in RDTs for VL, with sensitivities and specificities comparable to those obtained in serum samples, provided that the test kit is of overall good quality.

  2. [Benefits of using rapid HIV testing at the PMU-FLON walk-in clinic in Lausanne].

    Science.gov (United States)

    Gilgien, W; Aubert, J; Bischoff, T; Herzig, L; Perdrix, J

    2012-05-16

    Lab tests are frequently used in primary care to guide patient care. This is particularly the case when a severe disorder, or one that will affect patients' initial care, needs to be excluded rapidly. At the PMU-FLON walk-in clinic the use of HIV testing as recommended by the Swiss Office of Public Health was hampered by the delay in obtaining test results. This led us to introduce rapid HIV testing which provides results within 30 minutes. Following the first 250 tests the authors discuss the results as well as the benefits of rapid HIV testing in an urban walk-in clinic.

  3. Development and evaluation of an anti-rabies virus phosphoprotein-specific monoclonal antibody for detection of rabies neutralizing antibodies using RFFIT.

    Science.gov (United States)

    Um, Jihye; Chun, Byung Chul; Lee, Yeong Seon; Hwang, Kyu Jam; Yang, Dong-Kun; Park, Jun-Sun; Kim, Su Yeon

    2017-12-01

    Rabies is a major public health problem with a fatality rate close to 100%; however, complete prevention can be achieved through pre- or post-exposure prophylaxis. The rapid fluorescent focus inhibition test (RFFIT) is one of the recommended testing methods to determine the production of neutralizing antibodies after vaccination. Here, we report the development of a new monoclonal antibody (mAb) designed to react specifically with Rabies virus (RABV) phosphoprotein (P protein), and the evaluation of its applicability to the RFFIT and its effectiveness as a diagnostic reagent for human rabies. The mAb KGH P 16B8 was produced to target the P protein of the Korean KGH RABV strain. An indirect immunofluorescence assay (IFA) was conducted to detect various strains of RABV in various cell lines. Alexa-conjugated KGH P 16B8 (16B8-Alexa) was developed for the RFFIT. The IFA test could detect RABV up to a 1:2,500 dilution, with a detection limit comparable to that of a commercial diagnostic reagent. The sensitivity, specificity, positive predictive value, and negative predictive value of the RFFIT using 16B8-Alexa in 414 clinical specimens were 98.67%, 99.47%, 99.55%, and 98.42%, respectively. The results of the RFFIT with 16B8-Alexa were strongly correlated with those obtained using an existing commercial diagnostic reagent (r = 0.995, prabies neutralizing antibody titer and establish a diagnosis in human. Thus, 16B8-Alexa is expected to serve as an alternative diagnostic reagent that is widely accessible, with potentially broad applications beyond those of the RFFIT in Korea. Further studies with 16B8-Alexa should provide insight into the immunological mechanism of the P protein of Korean RABV.

  4. Effect of days in milk and milk yield on testing positive in milk antibody ELISA to Mycobacterium avium subsp. paratuberculosis in dairy cattle

    DEFF Research Database (Denmark)

    Nielsen, Søren Saxmose; Toft, Nils

    2012-01-01

    Milk samples are becoming more used as a diagnostic specimen for assessment of occurrence of antibodies to Mycobacterium avium subsp. paratuberculosis (MAP). This study assessed the effect of days in milk (DIM) and milk yield on testing positive in a commercial MAP specific milk antibody ELISA...... from the first couple of DIM should be excluded from MAP testing until further information on their significance is established. Milk yield also had a significant effect on odds of testing positive due to its diluting effect. Inclusion of milk yield in the interpretation of test results could improve...... among 222,774 Danish Holstein cows. Results showed that odds of testing positive on 1-2 DIM were 9-27 times higher than the rest of lactation, where the chance of testing positive varied less. The reason is most likely a high concentration of non-specific antibodies in colostrum. Consequently, samples...

  5. Expression of recombinant Antibodies

    Directory of Open Access Journals (Sweden)

    André eFrenzel

    2013-07-01

    Full Text Available Recombinant antibodies are highly specific detection probes in research, diagnostics and have emerged over the last two decades as the fastest growing class of therapeutic proteins. Antibody generation has been dramatically accelerated by in vitro selection systems, particularly phage display. An increasing variety of recombinant production systems have been developed, ranging from Gram-negative and positive bacteria, yeasts and filamentous fungi, insect cell lines, mammalian cells to transgenic plants and animals. Currently, almost all therapeutic antibodies are still produced in mammalian cell lines in order to reduce the risk of immunogenicity due to altered, non-human glycosylation patterns. However, recent developments of glycosylation-engineered yeast, insect cell lines and transgenic plants are promising to obtain antibodies with human-like post-translational modifications. Furthermore, smaller antibody fragments including bispecific antibodies without any glycosylation are successfully produced in bacteria and have advanced to clinical testing. The first therapeutic antibody products from a non-mammalian source can be expected in coming next years. In this review, we focus on current antibody production systems including their usability for different applications.

  6. The Anti-Acetylcholine Receptor Antibody Test in Suspected Ocular Myasthenia Gravis

    Directory of Open Access Journals (Sweden)

    Jung Jin Lee

    2014-01-01

    Full Text Available Aim. To estimate the clinical significance of anti-acetylcholine receptor antibody (anti-AChR-Ab levels in suspected ocular myasthenia gravis. Methods. In total, 144 patients complaining of fluctuating diplopia and ptosis were evaluated for serum levels of anti-acetylcholine receptor antibody and their medical charts were retrospectively reviewed. Subjects were classified into three groups: variable diplopia only, ptosis only, and both variable diplopia and ptosis. We investigated serum anti-AChR-Ab titer levels and performed thyroid autoantibody tests. Results. Patients’ chief complaints were diplopia (N=103, ptosis (N=12, and their concurrence (N=29. Abnormal anti-AChR-Ab was observed in 21 of 144 patients (14.1%. Between the three groups, mean age, number of seropositive patients, and mean anti-AChR-Ab level were not significantly different (P=0.224, 0.073, and 0.062, resp.. Overall, 27.5% of patients had abnormal thyroid autoantibodies. Conclusion. The sensitivity of anti-AChR-Ab was 14.1% in suspected ocular myasthenia gravis and seropositivity in myasthenia gravis patients showed a high correlation with the presence of thyroid autoantibodies.

  7. The significance for epidemiological studies anti-measles antibody detection examined by enzyme immunoassay (EIA) and plaque reduction neutralization test (PRNT).

    Science.gov (United States)

    Siennicka, Joanna; Częścik, Agnieszka; Trzcińska, Agnieszka

    2014-01-01

    The paper discusses the role of anti-measles antibodies for protection and significance for epidemiological studies determination of antibodies by different serological methods. The comparison of anti-measles virus antibodies levels measured by enzyme immunoassay (EIA) and Plaque Reduction Neutralization Test (PRNT) was described. It was found that the 200 mIU/ml of anti-measles activity measured by PRNT (level protection against symp- tomatic disease) is equivalent of 636 mIU/ml measured by EIA (Enzygnost®Anti-Measles Virus/IgG, Simens).

  8. Development of a colloidal gold immunochromatographic strip for rapid detection of Streptococcus agalactiae in tilapia.

    Science.gov (United States)

    Wen-de, Wu; Min, Li; Ming, Chen; Li-Ping, Li; Rui, Wang; Hai-Lan, Chen; Fu-Yan, Chen; Qiang, Mi; Wan-Wen, Liang; Han-Zhong, Chen

    2017-05-15

    A colloidal gold immunochromatographic strip was developed for rapid detection of Streptococcus agalactiae (S. agalactiae) infection in tilapia. The monoclonal antibodies (mAb) 4C12 and 3A9 were used to target S. agalactiae as colloidal gold-mAb conjugate and captured antibody, respectively. The colloidal gold immunochromatographic strip was assembled via routine procedures. Optimal pH and minimum antibody levels in the reaction system for gold colloidal-mAb 4C12 conjugation were pH 7.4 and 18μg/mL, respectively. Optimal concentrations of the captured antibody 3A9 and goat anti-mouse antibody were 0.6mg/mL and 2mg/mL, respectively. The sensitivity of the strip for detecting S. agalactiae was 1.5×10 5 colony forming units (CFU). No cross-reaction was observed with other commonly encountered bacteria, including Pseudomonas fluorescens, Aeromonas hydrophila, Vibrio anguillarum and Streptococcus iniae. The assay time for S. agalactiae was less than 15min. Tilapia samples artificially infected with S. agalactiae were tested using the newly developed strip. The results indicated that blood, brain, kidney, spleen, metanephros and intestine specimens of infected fish can be used for S. agalactiae detection. The validity of the strip was maintained for 6 months at 4°C. These findings suggested that the immunochromatographic strip was effective for spot and rapid detection of S. agalactiae infected tilapia. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Rapid micromotor-based naked-eye immunoassay.

    Science.gov (United States)

    de Ávila, Berta Esteban-Fernández; Zhao, Mingjiao; Campuzano, Susana; Ricci, Francesco; Pingarrón, José M; Mascini, Marcello; Wang, Joseph

    2017-05-15

    A dynamic micromotor-based immunoassay, exemplified by cortisol detection, based on the use of tubular micromotors functionalized with a specific antibody is described. The use of antibody-functionalized micromotors offers huge acceleration of both direct and competitive cortisol immunoassays, along with greatly enhanced sensitivity of direct and competitive immunoassays. The dramatically improved speed and sensitivity reflect the greatly increased likelihood of antibody-cortisol contacts and fluid mixing associated with the dynamic movement of these microtube motors and corresponding bubble generation that lead to a highly efficient and rapid recognition process. Rapid naked-eye detection of cortisol in the sample is achieved in connection to use of horseradish peroxidase (HRP) tag and TMB/H 2 O 2 system. Key parameters of the competitive immunoassay (e.g., incubation time and reaction volume) were optimized. This fast visual micromotor-based sensing approach enables "on the move" specific detection of the target cortisol down to 0.1μgmL -1 in just 2min, using ultrasmall (50µL) sample volumes. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Monoclonal antibody hapten radiopharmaceutical delivery

    International Nuclear Information System (INIS)

    Goodwin, D.A.; McTigue, M.

    1986-01-01

    One hundred μg of monoclonal antibody (MoAb) CHA255 with a binding constant Kb of 4 x 10 9 was complexed with indium-111 labelled BLEDTA II, BLEDTA IV, benzyl EDTA, and an EDTA conjugate of Fab. The 24-h tumour and organ distribution of BALB/c mice bearing KHJJ tumours was studied for each compound alone, the antibody complex, and 3 h following a chelate chase of the antibody complex. Whole body biological half-life was measured for 7 days with and without a chelate chase for each antibody complex. The 24-h whole body counts dropped 20 to 60% and blood concentration fell over 89% within 3 h of administering the chelate chase. Theoretical equivalent human organ doses were calculated from the 24-h organ concentrations, effective half-life, and MIRD 11 S values (absorbed dose per cumulated activity). Liver and spleen were the target organs, with the dose ranging from 0.50 to 3.91 rads mCi -1 . The reduction in organ radiation dose varied up to 95% following the chelate chase. Rapid selective renal clearance of chelate labelled radiopharmaceuticals by competitive inhibition (chelate chase) of their reversible binding to monoclonal antibodies enhances tumour imaging and improves the radiation dosimetry. (author)

  11. Rapid Bedside Inactivation of Ebola Virus for Safe Nucleic Acid Tests

    DEFF Research Database (Denmark)

    Rosenstierne, Maiken Worsøe; Karlberg, Helen; Bragstad, Karoline

    2016-01-01

    Rapid bedside inactivation of Ebola virus would be a solution for the safety of medical and technical staff, risk containment, sample transport, and high-throughput or rapid diagnostic testing during an outbreak. We show that the commercially available Magna Pure lysis/binding buffer used...... for nucleic acid extraction inactivates Ebola virus. A rapid bedside inactivation method for nucleic acid tests is obtained by simply adding Magna Pure lysis/binding buffer directly into vacuum blood collection EDTA tubes using a thin needle and syringe prior to sampling. The ready-to-use inactivation vacuum...... tubes are stable for more than 4 months, and Ebola virus RNA is preserved in the Magna Pure lysis/binding buffer for at least 5 weeks independent of the storage temperature. We also show that Ebola virus RNA can be manually extracted from Magna Pure lysis/binding buffer-inactivated samples using...

  12. Acceptability of rapid oral fluid HIV testing among male injection drug users in Taiwan, 1997 and 2007.

    Science.gov (United States)

    Lyu, Shu-Yu; Morisky, Donald E; Yeh, Ching-Ying; Twu, Shiing-Jer; Peng, Eugene Yu-Chang; Malow, Robert M

    2011-04-01

    Rapid oral fluid HIV testing (rapid oral testing) is in the process of being adapted in Taiwan and elsewhere given its advantages over prior HIV testing methods. To guide this process, we examined the acceptability of rapid oral testing at two time points (i.e., 1997 and 2007) among one of the highest risk populations, male injection drug users (IDUs). For this purpose, an anonymous self-administered survey was completed by HIV-negative IDUs involved in the criminal justice system in 1997 (N (1)=137 parolees) and 2007 (N (2)=106 prisoners). A social marketing model helped guide the design of our questionnaire to assess the acceptability of rapid oral testing. This included assessing a new product, across four marketing dimensions: product, price, promotion, and place. Results revealed that in both 1997 and 2007, over 90% indicated that rapid oral testing would be highly acceptable, particularly if the cost was under US$6, and that a pharmacy would be the most appropriate and accessible venue for selling the rapid oral testing kits. The vast majority of survey respondents believed that the cost of rapid oral testing should be federally subsidized and that television and newspaper advertisements would be the most effective media to advertise for rapid oral testing. Both the 1997 and 2007 surveys suggested that rapid oral HIV testing would be particularly accepted in Taiwan by IDUs after release from the criminal justice system.

  13. Diagnostic evaluation of rapid tests for scrub typhus in the Indian population is needed.

    Science.gov (United States)

    Shivalli, Siddharudha

    2016-05-12

    Owing to frequent outbreaks witnessed in different parts of the country in the recent past, scrub typhus is being described as a re-emerging infectious disease in India. Differentiating scrub typhus from other endemic diseases like malaria, leptospirosis, dengue fever, typhoid, etc. is difficult due to overlapping clinical features and a lower positivity for eschars in Asian populations. Hence, the diagnosis heavily relies on laboratory tests. Costs and the need of technical expertise limit the wide use of indirect immunoperoxidase or immunofluorescence assays, ELISA and PCR. The Weil-Felix test is the most commonly used and least expensive serological test, but lacks both sensitivity and specificity. Hence, the diagnosis of scrub typhus is often delayed or overlooked. With due consideration of the cost, rapidity, single test result and simplicity of interpretation, rapid diagnostic tests have come into vogue. However, evaluation of rapid diagnostic tests for scrub typhus in the Indian population is needed to justify or discourage their use. Research studies are needed to find the most suitable test in terms of the rapidity of the result, simplicity of the procedure, ease of interpretation and cost to be used in the Indian populace.

  14. Rapid high temperature field test method for evaluation of geothermal calcite scale inhibitors

    Energy Technology Data Exchange (ETDEWEB)

    Asperger, R.G.

    1982-08-01

    A test method is described which allows the rapid field testing of calcite scale inhibitors in high- temperature geothermal brines. Five commercial formulations, chosen on the basis of laboratory screening tests, were tested in brines with low total dissolved solids at ca 500 F. Four were found to be effective; of these, 2 were found to be capable of removing recently deposited scale. One chemical was tested in the full-flow brine line for 6 wks. It was shown to stop a severe surface scaling problem at the well's control valve, thus proving the viability of the rapid test method. (12 refs.)

  15. Solid-phase peptide quantitation assay using labeled monoclonal antibody and glutaraldehyde fixation

    International Nuclear Information System (INIS)

    Kasprzyk, P.G.; Cuttitta, F.; Avis, I.; Nakanishi, Y.; Treston, A.; Wong, H.; Walsh, J.H.; Mulshine, J.L.

    1988-01-01

    A solid-phase radioimmunoassay utilizing iodinated peptide-specific monoclonal antibody as a detection system instead of labeled peptide has been developed. Regional specific monoclonal antibodies to either gastrin-releasing peptide or gastrin were used as models to validate the general application of our modified assay. Conditions for radioactive labeling of the monoclonal antibody were determined to minimize oxidant damage, which compromises the sensitivity of other reported peptide quantitation assays. Pretreatment of 96-well polyvinyl chloride test plates with a 5% glutaraldehyde solution resulted in consistent retention of sufficient target peptide on the solid-phase matrix to allow precise quantitation. This quantitative method is completed within 1 h of peptide solid phasing. Pretreatment of assay plates with glutaraldehyde increased binding of target peptide and maximized antibody binding by optimizing antigen presentation. The hypothesis that glutaraldehyde affects both peptide binding to the plate and orientation of the peptide was confirmed by analysis of several peptide analogs. These studies indicate that peptide binding was mediated through a free amino group leaving the carboxy-terminal portion of the target peptide accessible for antibody binding. It was observed that the length of the peptide also affects the amount of monoclonal antibody that will bind. Under the optimal conditions, results from quantitation of gastrin-releasing peptide in relevant samples agree well with those from previously reported techniques. Thus, we report here a modified microplate assay which may be generally applied for the rapid and sensitive quantitation of peptide hormones

  16. Antibody response to the lipopolysaccharide and protein antigens of Salmonella typhi during typhoid infection. I. Measurement of serum antibodies by radioimmunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Tsang, R S.W.; Chau, P Y; Lam, S K [Hong Kong Univ.; La Brooy, J T; Rowley, D [Adelaide Univ. (Australia)

    1981-12-01

    Serum antibody responses to the lipopolysaccharide and protein antigens of S. typhi in typhoid patients were studied using a solid-phase radioimmunoassay technique with /sup 125/I labelled anti-immunoglobulin antibody. Sera from 24 adult typhoid patients and 20 non-typhoid adult controls were compared. As a group, sera from typhoid patients showed increased IgA, IgG and IgM immunoglobulin levels and gave significantly higher anti-LPS and anti-protein antibody titres in all three major immunoglobulin classes than did non-typhoid controls. Levels of antibodies against LPS or protein in sera of typhoid patients were highly variable with a skew distribution. A good correlation was found between antibody titres to the LPS antigen and those to a protein antigen. No correlation, however, was found between the anti-LPS antibody titres measured by radioimmunoassay and the anti-O antibody titres measured by the Widal agglutination test. Titration of anti-LPS or anti-protein antibodies by radioimmunoassay was found to be more sensitive and specific than Widal test for the serological diagnosis of typhoid fever. The advantages of measuring antibody response by radioimmunoassay over conventional Widal test are discussed.

  17. Rapid and simultaneous detection of human hepatitis B virus and hepatitis C virus antibodies based on a protein chip assay using nano-gold immunological amplification and silver staining method

    Directory of Open Access Journals (Sweden)

    Wan Zhixiang

    2005-07-01

    Full Text Available Abstract Background Viral hepatitis due to hepatitis B virus and hepatitis C virus are major public health problems all over the world. Traditional detection methods including polymerase chain reaction (PCR-based assays and enzyme-linked immunosorbent assays (ELISA are expensive and time-consuming. In our assay, a protein chip assay using Nano-gold Immunological Amplification and Silver Staining (NIASS method was applied to detect HBV and HCV antibodies rapidly and simultaneously. Methods Chemically modified glass slides were used as solid supports (named chip, on which several antigens, including HBsAg, HBeAg, HBcAg and HCVAg (a mixture of NS3, NS5 and core antigens were immobilized respectively. Colloidal nano-gold labelled staphylococcal protein A (SPA was used as an indicator and immunogold silver staining enhancement technique was applied to amplify the detection signals, producing black image on array spots, which were visible with naked eyes. To determine the detection limit of the protein chip assay, a set of model arrays in which human IgG was spotted were structured and the model arrays were incubated with different concentrations of anti-IgG. A total of 305 serum samples previously characterized with commercial ELISA were divided into 4 groups and tested in this assay. Results We prepared mono-dispersed, spherical nano-gold particles with an average diameter of 15 ± 2 nm. Colloidal nano-gold-SPA particles observed by TEM were well-distributed, maintaining uniform and stable. The optimum silver enhancement time ranged from 8 to 12 minutes. In our assay, the protein chips could detect serum antibodies against HBsAg, HBeAg, HBcAg and HCVAg with the absence of the cross reaction. In the model arrays, the anti-IgG as low as 3 ng/ml could be detected. The data for comparing the protein chip assay with ELISA indicated that no distinct difference (P > 0.05 existed between the results determined by our assay and ELISA respectively. Conclusion

  18. Insulin radioimmunoassay kit (125I) using polyethyleneglycol (PEG) and a double antibody separation method

    International Nuclear Information System (INIS)

    Borza, Virginia; Chariton, Delfina; Neacsu, Elena

    1997-01-01

    Insulin is a polypeptide hormone formed from proinsulin in the b-cells of the islets of Langerhans in the pancreas. It has a widespread effect on carbohydrate, lipid and protein metabolism. Diabetes mellitus is the result of an insulin deficiency brought about either by insufficient insulin secretion or by rapid insulin catabolism. The determination of the insulin level is important for differential etiologic diagnosis and subsequent therapy and prognosis. Insulin radioimmunoassay kit provides a sensitive, precise and specific assay for insulin concentration in serum. Standard and insulin in the patient sample compete with tracer for binding sites on an insulin antibody. The antigen-antibody combination, which forms during incubation time, will be separated from free insulin by different methods. The separation technique using the double antibody technique combined with Polyethyleneglycol (PEG) is presented. The results are compared with the separation method using PEG alone and with double antibody technique. Antiserum to insulin was produced in rats immunized with porcine insulin, while rabbits immunized with rat-g globulin were used as a source for the second antibody.The tested PEG was PEG 6000. The best results were obtained using the double antibody at a 1/50 dilution combined with 7.5 PEG solutions. The time for precipitating the antibody bound fraction by this technique was established to be 30 minutes. The results obtained using this method as separation technique for insulin - antibody complex were better than those obtained using the double antibody techniques or PEG as precipitating agent alone. (authors)

  19. Simple, rapid, and affordable point-of-care test for the serodiagnosis of typhoid fever

    NARCIS (Netherlands)

    Pastoor, Rob; Hatta, Mochammad; Abdoel, Theresia H.; Smits, Henk L.

    2008-01-01

    We developed a point-of-care test for the serodiagnosis of typhoid fever in the format of an immunochromatographic lateral flow assay. The flow assay for typhoid fever is based on the detection of Salmonella enterica serotype Typhi lipopolysaccharide-specific immunoglobulin M (IgM) antibodies. The

  20. Repeat confirmatory testing for persons with discordant whole blood and oral fluid rapid HIV test results: findings from post marketing surveillance.

    Science.gov (United States)

    Wesolowski, Laura G; Mackellar, Duncan A; Ethridge, Steven F; Zhu, Julia H; Owen, S Michele; Sullivan, Patrick S

    2008-02-06

    Reactive oral fluid and whole blood rapid HIV tests must be followed with a confirmatory test (Western blot (WB), immunofluorescent assay (IFA) or approved nucleic acid amplification test (NAAT)). When the confirmatory result is negative or indeterminate (i.e. discordant with rapid result), repeat confirmatory testing should be conducted using a follow-up specimen. Previous reports have not described whether repeat testing adequately resolves the HIV-infection status of persons with discordant results. Post-marketing surveillance was conducted in 368 testing sites affiliated with 14 state and 2 city health departments from August 11, 2004 to June 30, 2005 and one health department through December 31, 2005. For persons with discordant results, data were collected on demographics, risk behaviors, HIV test results and specimen types. Persons with repeat confirmatory results were classified as HIV-infected or uninfected. Regression models were created to assess risk factors for not having repeat testing. Of 167,371 rapid tests conducted, 2589 (1.6%) were reactive: of these, 2417 (93%) had positive WB/IFA, 172 (7%) had negative or indeterminate WB/IFA. Of 89/172 (52%) persons with a repeat confirmatory test: 17 (19%) were HIV-infected, including 3 with indeterminate WB and positive NAAT; 72 (81%) were uninfected, including 12 with repeat indeterminate WB. Factors associated with HIV-infection included having an initial indeterminate WB/IFA (vs. negative) (ptest [adjusted OR 2.6, 95% CI (1.3, 4.9)]. Though only half of persons with discordant results had repeat confirmatory testing, of those who did, nearly one in five were HIV-infected. These findings underscore the need for rapid HIV testing programs to increase repeat confirmatory testing for persons with discordant results. Because of the lower sensitivity of oral fluid WBs, confirmatory testing following a reactive rapid test should be conducted using serum or plasma, when possible.

  1. The processing and fate of antibodies and their radiolabels bound to the surface of tumor cells in vitro: A comparison of nine radiolabels

    International Nuclear Information System (INIS)

    Shih, L.B.; Thorpe, S.R.; Griffiths, G.L.; Diril, H.; Ong, G.L.; Hansen, H.J.; Goldenberg, D.M.; Mattes, M.J.

    1994-01-01

    Processing radiolabeled degradation products is the key factor affecting retention of antibodies within the cell. In this study, the authors have analyzed the processing of antibodies labeled in nine different ways. Antibodies were labeled with three different radioisotopes and seven different forms of 125 I. Eight of the radiolabels (except 188 Re) were conjugated to the same antibody, MA103, and tested on the renal carcinoma cell line SK-RC-18 and/or the ovarian carcinoma cell line SK-OV-6. Rhenium conjugation utilized the antibody RS7, the target cell line ME180 and three of the other radiolabels were also tested with this antibody-target cell combination for comparison. Iodine conjugated to antibodies by conventional methods was rapidly released from the cell after antibody catabolism. In contrast, iodinated moieties, such as dilactitol-tyramine and inulin-tyramine were retained within cells four to five times longer. The use of radiolabels that are trapped within cells after antibody catabolism can potentially increase the dose of radiation delivered to the tumor, from the same amount of radioactivity deposited by a factor of four or five. The prolonged retention of 111 In relative to 125 I is not due to deiodination of iodine conjugates, but rather to intracellular retention of catabolic products containing 111 In, perhaps within lysosomes. 45 refs., 4 figs., 1 tab

  2. Simple and rapid field tests for brucellosis in livestock

    NARCIS (Netherlands)

    Abdoel, Theresia; Dias, Isabel Travassos; Cardoso, Regina; Smits, Henk L.

    2008-01-01

    Four simple and rapid field tests for the serodiagnosis of brucellosis in cattle, goat, sheep and swine were developed. The performance of the assays was investigated using serum samples collected in Portugal from animals originating from herds with a defined sanitary status with respect to the

  3. Factors predicting the acceptance of herpes simplex virus type 2 antibody testing among adolescents and young adults.

    Science.gov (United States)

    Zimet, Gregory D; Rosenthal, Susan L; Fortenberry, J Dennis; Brady, Rebecca C; Tu, Wanzhu; Wu, Jingwei; Bernstein, David I; Stanberry, Lawrence R; Stone, Katherine M; Leichliter, Jami S; Fife, Kenneth H

    2004-11-01

    The rates and determinants of acceptance of herpes simplex virus type 2 (HSV-2) testing have not been adequately studied. The objective of this study was to identify factors associated with acceptance of HSV-2 antibody testing in individuals with no history of genital herpes. We conducted a cross-sectional survey study followed by the offer of free HSV-2 serologic testing at an urban sexually transmitted disease (STD) clinic, 2 general adult medical clinics, an urban university campus, and an urban adolescent medicine clinic. A total of 1199 individuals aged 14 to 30 years completed the survey and were offered testing. A total of 68.4% accepted HSV-2 testing. Factors independently associated with acceptance were female sex, older age, having an STD history, having 1 or more sexual partners in the last 6 months, perceived vulnerability to HSV-2 infection, and perceived benefits of HSV-2 testing. Fear of needles predicted rejection of testing, as did attending a general medical clinic versus an STD clinic and nonwhite race. There is a substantial interest in HSV-2 antibody testing across a variety of settings. Those at greatest behavioral and historic risk for HSV-2 infection, women, and persons whose health beliefs are consistent with testing are more likely to accept serologic testing when it is offered.

  4. The Ausab test - a radioimmunoassay in the solid phase for the detection of antibodies against HBsAg

    International Nuclear Information System (INIS)

    Lange, W.; Koehler, H.; Apodaca, J.

    1974-01-01

    The suitability of a newly developed RIA (Ausab test, Abbott laboratories) for the detection of antibodies against the Hepatitis B (surface) antigen (HBsAg) has been tested on 1968 sera of blood donors. Reproducibility test and specificity test were included. During the examination the technique of the Ausab test was changed from the original one-step to the two-step procedure. With the one-step technique 431 of 1968 sera (21.9%) showed positive reactions. During the test problems concerning the differentiation between positive and negative results were encountered due to high unspecific binding of radioactivity. Positive sera were re-examined employing the two-step technique and only 77.4% of the previously positive reactions could be reproduced. 50 sera that were negative in the one-step test remained negative in the two-step test. Difficulties concerning nonspecific binding of radioactivity as observed with the one-step technique were not encountered with the two-step procedure. On 92 of the confirmed positive sera a specificity test was run and 90 (97.8%) proved to be specific. A calculated 16.5% of the blood donors in Berlin have to be considered as antibody carriers. Only 6 of the Ausab positive sera were found to give positive reactions in CEP. 3 sera that were initially positive in CEP could neither be confirmed in a repeated CEP nor in the Ausab test. (orig.) [de

  5. Protective levels of canine distemper virus antibody in an urban dog population using plaque reduction neutralization test

    Directory of Open Access Journals (Sweden)

    O.I. Oyedele

    2004-11-01

    Full Text Available Blood samples from 50 dogs were collected at three veterinary clinics in Ibadan and Abuja, Nigeria and the serum from each sample was evaluated serologically for neutralizing antibodies against canine distemper virus (CDV by the highly sensitive plaque reduction (PRN neutralization assay. Thirteen dogs had plaque reduction neutralization titres of 0-100, seven had titres of 100-1 000 while 30 had titres ranging from 1 000-6 000. The PRN titres of vaccinated dogs were found to be significantly higher than unvaccinated dogs. The widespread use of the highly reproducible PRN test for the evaluation of antibody response to CDV may be very important in the generation of international CDV positive serum standards that should help to improve pre-and post-vaccination testing of dogs worldwide.

  6. Feasibility of utilizing the SD BIOLINE Onchocerciasis IgG4 rapid test in onchocerciasis surveillance in Senegal

    Science.gov (United States)

    Dieye, Yakou; Barrett, Kelsey L.; Gerth-Guyette, Emily; Di Giorgio, Laura; Golden, Allison; Faulx, Dunia; Kalnoky, Michael; Ndiaye, Marie Khemesse Ngom; Sy, Ngayo; Mané, Malang; Faye, Babacar; Sarr, Mamadou; Dioukhane, Elhadji Mamadou; Peck, Roger B.; Guinot, Philippe; de los Santos, Tala

    2017-01-01

    As effective onchocerciasis control efforts in Africa transition to elimination efforts, different diagnostic tools are required to support country programs. Senegal, with its long standing, successful control program, is transitioning to using the SD BIOLINE Onchocerciasis IgG4 (Ov16) rapid test over traditional skin snip microscopy. The aim of this study is to demonstrate the feasibility of integrating the Ov16 rapid test into onchocerciasis surveillance activities in Senegal, based on the following attributes of acceptability, usability, and cost. A cross-sectional study was conducted in 13 villages in southeastern Senegal in May 2016. Individuals 5 years and older were invited to participate in a demographic questionnaire, an Ov16 rapid test, a skin snip biopsy, and an acceptability interview. Rapid test technicians were interviewed and a costing analysis was conducted. Of 1,173 participants, 1,169 (99.7%) agreed to the rapid test while 383 (32.7%) agreed to skin snip microscopy. The sero-positivity rate of the rapid test among those tested was 2.6% with zero positives 10 years and younger. None of the 383 skin snips were positive for Ov microfilaria. Community members appreciated that the rapid test was performed quickly, was not painful, and provided reliable results. The total costs for this surveillance activity was $22,272.83, with a cost per test conducted at $3.14 for rapid test, $7.58 for skin snip microscopy, and $13.43 for shared costs. If no participants had refused skin snip microscopy, the total cost per method with shared costs would have been around $16 per person tested. In this area with low onchocerciasis sero-positivity, there was high acceptability and perceived value of the rapid test by community members and technicians. This study provides evidence of the feasibility of implementing the Ov16 rapid test in Senegal and may be informative to other country programs transitioning to Ov16 serologic tools. PMID:28972982

  7. Feasibility of utilizing the SD BIOLINE Onchocerciasis IgG4 rapid test in onchocerciasis surveillance in Senegal.

    Directory of Open Access Journals (Sweden)

    Yakou Dieye

    2017-10-01

    Full Text Available As effective onchocerciasis control efforts in Africa transition to elimination efforts, different diagnostic tools are required to support country programs. Senegal, with its long standing, successful control program, is transitioning to using the SD BIOLINE Onchocerciasis IgG4 (Ov16 rapid test over traditional skin snip microscopy. The aim of this study is to demonstrate the feasibility of integrating the Ov16 rapid test into onchocerciasis surveillance activities in Senegal, based on the following attributes of acceptability, usability, and cost. A cross-sectional study was conducted in 13 villages in southeastern Senegal in May 2016. Individuals 5 years and older were invited to participate in a demographic questionnaire, an Ov16 rapid test, a skin snip biopsy, and an acceptability interview. Rapid test technicians were interviewed and a costing analysis was conducted. Of 1,173 participants, 1,169 (99.7% agreed to the rapid test while 383 (32.7% agreed to skin snip microscopy. The sero-positivity rate of the rapid test among those tested was 2.6% with zero positives 10 years and younger. None of the 383 skin snips were positive for Ov microfilaria. Community members appreciated that the rapid test was performed quickly, was not painful, and provided reliable results. The total costs for this surveillance activity was $22,272.83, with a cost per test conducted at $3.14 for rapid test, $7.58 for skin snip microscopy, and $13.43 for shared costs. If no participants had refused skin snip microscopy, the total cost per method with shared costs would have been around $16 per person tested. In this area with low onchocerciasis sero-positivity, there was high acceptability and perceived value of the rapid test by community members and technicians. This study provides evidence of the feasibility of implementing the Ov16 rapid test in Senegal and may be informative to other country programs transitioning to Ov16 serologic tools.

  8. Feasibility of utilizing the SD BIOLINE Onchocerciasis IgG4 rapid test in onchocerciasis surveillance in Senegal.

    Science.gov (United States)

    Dieye, Yakou; Storey, Helen L; Barrett, Kelsey L; Gerth-Guyette, Emily; Di Giorgio, Laura; Golden, Allison; Faulx, Dunia; Kalnoky, Michael; Ndiaye, Marie Khemesse Ngom; Sy, Ngayo; Mané, Malang; Faye, Babacar; Sarr, Mamadou; Dioukhane, Elhadji Mamadou; Peck, Roger B; Guinot, Philippe; de Los Santos, Tala

    2017-10-01

    As effective onchocerciasis control efforts in Africa transition to elimination efforts, different diagnostic tools are required to support country programs. Senegal, with its long standing, successful control program, is transitioning to using the SD BIOLINE Onchocerciasis IgG4 (Ov16) rapid test over traditional skin snip microscopy. The aim of this study is to demonstrate the feasibility of integrating the Ov16 rapid test into onchocerciasis surveillance activities in Senegal, based on the following attributes of acceptability, usability, and cost. A cross-sectional study was conducted in 13 villages in southeastern Senegal in May 2016. Individuals 5 years and older were invited to participate in a demographic questionnaire, an Ov16 rapid test, a skin snip biopsy, and an acceptability interview. Rapid test technicians were interviewed and a costing analysis was conducted. Of 1,173 participants, 1,169 (99.7%) agreed to the rapid test while 383 (32.7%) agreed to skin snip microscopy. The sero-positivity rate of the rapid test among those tested was 2.6% with zero positives 10 years and younger. None of the 383 skin snips were positive for Ov microfilaria. Community members appreciated that the rapid test was performed quickly, was not painful, and provided reliable results. The total costs for this surveillance activity was $22,272.83, with a cost per test conducted at $3.14 for rapid test, $7.58 for skin snip microscopy, and $13.43 for shared costs. If no participants had refused skin snip microscopy, the total cost per method with shared costs would have been around $16 per person tested. In this area with low onchocerciasis sero-positivity, there was high acceptability and perceived value of the rapid test by community members and technicians. This study provides evidence of the feasibility of implementing the Ov16 rapid test in Senegal and may be informative to other country programs transitioning to Ov16 serologic tools.

  9. Affinity chromatography: A versatile technique for antibody purification.

    Science.gov (United States)

    Arora, Sushrut; Saxena, Vikas; Ayyar, B Vijayalakshmi

    2017-03-01

    Antibodies continue to be extremely utilized entities in myriad applications including basic research, imaging, targeted delivery, chromatography, diagnostics, and therapeutics. At production stage, antibodies are generally present in complex matrices and most of their intended applications necessitate purification. Antibody purification has always been a major bottleneck in downstream processing of antibodies, due to the need of high quality products and associated high costs. Over the years, extensive research has focused on finding better purification methodologies to overcome this holdup. Among a plethora of different techniques, affinity chromatography is one of the most selective, rapid and easy method for antibody purification. This review aims to provide a detailed overview on affinity chromatography and the components involved in purification. An array of support matrices along with various classes of affinity ligands detailing their underlying working principles, together with the advantages and limitations of each system in purifying different types of antibodies, accompanying recent developments and important practical methodological considerations to optimize purification procedure are discussed. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Evaluation of microscopy and rapid diagnostic tests in screening ...

    African Journals Online (AJOL)

    Malaria is a life-threatening disease caused by the protozoa of the genus Plasmodium. Infection of individual is through the bites of infected female Anopheles mosquitoes. This study evaluated the performance of microscopy and rapid diagnostic tests (RDTs) in diagnosing malaria. A total of 400 clinically suspected malaria ...

  11. Analytical Validation of the ReEBOV Antigen Rapid Test for Point-of-Care Diagnosis of Ebola Virus Infection

    Science.gov (United States)

    Cross, Robert W.; Boisen, Matthew L.; Millett, Molly M.; Nelson, Diana S.; Oottamasathien, Darin; Hartnett, Jessica N.; Jones, Abigal B.; Goba, Augustine; Momoh, Mambu; Fullah, Mohamed; Bornholdt, Zachary A.; Fusco, Marnie L.; Abelson, Dafna M.; Oda, Shunichiro; Brown, Bethany L.; Pham, Ha; Rowland, Megan M.; Agans, Krystle N.; Geisbert, Joan B.; Heinrich, Megan L.; Kulakosky, Peter C.; Shaffer, Jeffrey G.; Schieffelin, John S.; Kargbo, Brima; Gbetuwa, Momoh; Gevao, Sahr M.; Wilson, Russell B.; Saphire, Erica Ollmann; Pitts, Kelly R.; Khan, Sheik Humarr; Grant, Donald S.; Geisbert, Thomas W.; Branco, Luis M.; Garry, Robert F.

    2016-01-01

    Background. Ebola virus disease (EVD) is a severe viral illness caused by Ebola virus (EBOV). The 2013–2016 EVD outbreak in West Africa is the largest recorded, with >11 000 deaths. Development of the ReEBOV Antigen Rapid Test (ReEBOV RDT) was expedited to provide a point-of-care test for suspected EVD cases. Methods. Recombinant EBOV viral protein 40 antigen was used to derive polyclonal antibodies for RDT and enzyme-linked immunosorbent assay development. ReEBOV RDT limits of detection (LOD), specificity, and interference were analytically validated on the basis of Food and Drug Administration (FDA) guidance. Results. The ReEBOV RDT specificity estimate was 95% for donor serum panels and 97% for donor whole-blood specimens. The RDT demonstrated sensitivity to 3 species of Ebolavirus (Zaire ebolavirus, Sudan ebolavirus, and Bundibugyo ebolavirus) associated with human disease, with no cross-reactivity by pathogens associated with non-EBOV febrile illness, including malaria parasites. Interference testing exhibited no reactivity by medications in common use. The LOD for antigen was 4.7 ng/test in serum and 9.4 ng/test in whole blood. Quantitative reverse transcription–polymerase chain reaction testing of nonhuman primate samples determined the range to be equivalent to 3.0 × 105–9.0 × 108 genomes/mL. Conclusions. The analytical validation presented here contributed to the ReEBOV RDT being the first antigen-based assay to receive FDA and World Health Organization emergency use authorization for this EVD outbreak, in February 2015. PMID:27587634

  12. Rapid screening test for porphyria diagnosis using fluorescence spectroscopy

    Science.gov (United States)

    Lang, A.; Stepp, H.; Homann, C.; Hennig, G.; Brittenham, G. M.; Vogeser, M.

    2015-07-01

    Porphyrias are rare genetic metabolic disorders, which result from deficiencies of enzymes in the heme biosynthesis pathway. Depending on the enzyme defect, different types of porphyrins and heme precursors accumulate for the different porphyria diseases in erythrocytes, liver, blood plasma, urine and stool. Patients with acute hepatic porphyrias can suffer from acute neuropathic attacks, which can lead to death when undiagnosed, but show only unspecific clinical symptoms such as abdominal pain. Therefore, in addition to chromatographic methods, a rapid screening test is required to allow for immediate identification and treatment of these patients. In this study, fluorescence spectroscopic measurements were conducted on blood plasma and phantom material, mimicking the composition of blood plasma of porphyria patients. Hydrochloric acid was used to differentiate the occurring porphyrins (uroporphyrin-III and coproporphyrin-III) spectroscopically despite their initially overlapping excitation spectra. Plasma phantom mixtures were measured using dual wavelength excitation and the corresponding concentrations of uroporphyrin-III and coproporphyrin-III were determined. Additionally, three plasma samples of porphyria patients were examined and traces of coproporphyrin-III and uroporphyrin-III were identified. This study may therefore help to establish a rapid screening test method with spectroscopic differentiation of the occurring porphyrins, which consequently allows for the distinction of different porphyrias. This may be a valuable tool for clinical porphyria diagnosis and rapid or immediate treatment.

  13. Design, development and evaluation of rK28-based point-of-care tests for improving rapid diagnosis of visceral leishmaniasis.

    Directory of Open Access Journals (Sweden)

    Sowmya Pattabhi

    Full Text Available BACKGROUND: Visceral leishmaniasis (VL is diagnosed by microscopic confirmation of the parasite in bone marrow, spleen or lymph node aspirates. These procedures are unsuitable for rapid diagnosis of VL in field settings. The development of rK39-based rapid diagnostic tests (RDT revolutionized diagnosis of VL by offering high sensitivity and specificity in detecting disease in the Indian subcontinent; however, these tests have been less reliable in the African subcontinent (sensitivity range of 75-85%, specificity of 70-92%. We have addressed limitations of the rK39 with a new synthetic polyprotein, rK28, followed by development and evaluation of two new rK28-based RDT prototype platforms. METHODOLOGY/PRINCIPAL FINDINGS: Evaluation of 62 VL-confirmed sera from Sudan provided sensitivities of 96.8% and 93.6% (95% CI = K28: 88.83-99.61%; K39: 84.30-98.21% and specificities of 96.2% and 92.4% (95% CI = K28: 90.53-98.95%; K39: 85.54-96.65% for rK28 and rK39, respectively. Of greater interest was the observation that individual VL sera with low rK39 reactivity often had much higher rK28 reactivity. This characteristic of the fusion protein was exploited in the development of rK28 rapid tests, which may prove to be crucial in detecting VL among patients with low rK39 antibody levels. Evaluation of two prototype lateral flow-based rK28 rapid tests on 53 VL patients in Sudan and 73 VL patients in Bangladesh provided promisingly high sensitivities (95.9% [95% CI = 88.46-99.1 in Sudan and 98.1% [95% CI = 89.93-99.95%] in Bangladesh compared to the rK39 RDT (sensitivities of 86.3% [95% CI = 76.25-93.23%] in Sudan and 88.7% [95% CI = 76.97-95.73%] in Bangladesh. CONCLUSIONS/SIGNIFICANCE: Our study compares the diagnostic accuracy of rK39 and rK28 in detecting active VL cases and our findings indicate that rK28 polyprotein has great potential as a serodiagnostic tool. A new rK28-based RDT will prove to be a valuable asset in

  14. Development of a Novel, Ultra-rapid Biosensor for the Qualitative Detection of Hepatitis B Virus-associated Antigens and Anti-HBV, Based on “Membrane-engineered” Fibroblast Cells with Virus-Specific Antibodies and Antigens

    Directory of Open Access Journals (Sweden)

    Antonios Perdikaris

    2009-03-01

    Full Text Available A novel miniature cell biosensor detection system for the detection of Hepatis B virus (HBV-associated antigens and anti-HBV is described. The biosensor is based on “membrane-engineered” Vero fibroblast cells immobilized in an alginate matrix. The membrane-engineering process involved the electroinsertion of anti-HBV specific antibodies (anti-HBs, anti-HBe or antigens (HBsAg in the membranes of the Vero cells. The attachment of a homologous antigen to the electroinserted antibody (or, respectively, of the antibody to the electroinserted antigen triggered specific changes to the cell membrane potential that were measured by appropriate microelectrodes, according to the principle of the Bioelectric Recognition Assay (BERA. The sensor was used for screening 133 clinical blood serum samples according to a double-blind protocol. Considerably higher sensor responses were observed against HBV-positive samples, compared with responses against negative samples or samples positive for heterologous hepatitis viruses such as Hepatitis C (HCV virus. Detection of anti-HBs antibodies was made possible by using a biosensor based on immobilized Vero cells bearing the respective antigen (HBsAg. The observed response was rapid (45 sec and quite reproducible. Fluorescence microscopy observations showed that attachment of HBV particles to cells membrane-engineered with anti-HBs was associated with a decrease of [Ca2+]cyt. The perspectives for using the novel biosensor as a qualitative, rapid screening, high throughput assay for HBV antigens and anti-HBs in clinical samples is discussed.

  15. Test plan for demonstration of Rapid Transuranic Monitoring Laboratory

    International Nuclear Information System (INIS)

    McIsaac, C.V.; Sill, C.W.; Gehrke, R.J.; Killian, E.W.; Watts, K.D.

    1993-06-01

    This plan describes tests to demonstrate the capability of the Rapid Transuranic Monitoring Laboratory (RTML) to monitor airborne alpha-emitting radionuclides and analyze soil, smear, and filter samples for alpha- and gamma-emitting radionuclides under field conditions. The RTML will be tested during June 1993 at a site adjacent to the Cold Test Pit at the Radioactive Waste Management Complex at the Idaho National Engineering Laboratory. Measurement systems installed in the RTML that will be demonstrated include two large-area ionization chamber alpha spectrometers, an x-ray/gamma-ray spectrometer, and four alpha continuous air monitors. Test objectives, requirements for data quality, experimental apparatus and procedures, and safety and logistics issues are described

  16. Rapid-cycle testing cuts bed turnaround by 85%.

    Science.gov (United States)

    2004-11-01

    You can use rapid-cycle testing to try out new approaches to overcrowding much more frequently than with more traditional process improvement strategies. Improving bed turnaround notification can yield dramatic improvements. Telling staff they have to try a new process only for three days makes it easier to gain buy-in. Look for old policies that are no longer needed, yet continue to keep your staff bogged down.

  17. Diagnostic performance of serological tests to detect antibodies against acute scrub typhus infection in central India

    Directory of Open Access Journals (Sweden)

    Kiran Pote

    2018-01-01

    Full Text Available Background: Differentiating scrub typhus from other acute febrile illness is difficult due to non specificity of clinical symptoms and relative absence of eschar in Indian population. The diagnosis thus relies mainly on laboratory tests. Antibody based serological tests are mainstay of scrub typhus diagnosis. Here, we evaluated the diagnostic performance of IgM ELISA, IgM IFA and ICT to detect antibodies against O. tsutsugamushi in acute serum of febrile patients. Methodology: The serum samples from 600 randomly selected patients suffering from acute undifferentiated fever were tested by all the three tests mentioned above. We used latent class analysis to generate unbiased results as all the tests for scrub typhus diagnosis are imperfect and none of them can be considered as reference standard. Results: We found that IgM ELISA with cutoff titer 0.5 OD has high diagnostic accuracy (sensitivity 99.9% and specificity 99.15 than IgM IFA (sensitivity 96.8% and specificity 99.7% for scrub typhus diagnosis. ICT used in our study had very high specificity 100% but low sensitivity (38% which would limit its use for acute serum samples. ICT being a screening or point of care test, has to be more sensitive while some compromise with specificity is affordable. Hence, optimal cutoff for ICT should be evaluated under different settings. Conclusion: IgM ELISA being simple and affordable could be an alternative diagnostic test to IgM IFA which is subjective and costly.

  18. Diagnostic performance of serological tests to detect antibodies against acute scrub typhus infection in central India.

    Science.gov (United States)

    Pote, Kiran; Narang, Rahul; Deshmukh, Pradeep

    2018-01-01

    Differentiating scrub typhus from other acute febrile illness is difficult due to non specificity of clinical symptoms and relative absence of eschar in Indian population. The diagnosis thus relies mainly on laboratory tests. Antibody based serological tests are mainstay of scrub typhus diagnosis. Here, we evaluated the diagnostic performance of IgM ELISA, IgM IFA and ICT to detect antibodies against O. tsutsugamushi in acute serum of febrile patients. The serum samples from 600 randomly selected patients suffering from acute undifferentiated fever were tested by all the three tests mentioned above. We used latent class analysis to generate unbiased results as all the tests for scrub typhus diagnosis are imperfect and none of them can be considered as reference standard. We found that IgM ELISA with cutoff titer 0.5 OD has high diagnostic accuracy (sensitivity 99.9% and specificity 99.15) than IgM IFA (sensitivity 96.8% and specificity 99.7%) for scrub typhus diagnosis. ICT used in our study had very high specificity 100% but low sensitivity (38%) which would limit its use for acute serum samples. ICT being a screening or point of care test, has to be more sensitive while some compromise with specificity is affordable. Hence, optimal cutoff for ICT should be evaluated under different settings. IgM ELISA being simple and affordable could be an alternative diagnostic test to IgM IFA which is subjective and costly.

  19. Periodontal disease and Helicobacter pylori infection: a community-based study using serology and rapid urease test.

    Science.gov (United States)

    Nisha, Krishnavilasom J; Nandakumar, Krishnankutty; Shenoy, Kottacherry T; Janam, Presanthila

    2016-02-01

    The aims of the present study were to assess the prevalence of periodontal disease and Helicobacter pylori (H. pylori) infection and their associations within a predefined Indian population. A community-based cross-sectional study of 500 selected individuals using a questionnaire, oral examination, rapid urease testing of dental plaque, and serological examination for immunoglobulin G antibody to H. pylori was carried out. Periodontal disease and H. pylori infection were prevalent in more than 50% of the population. Age, smoking, and diabetic status of the individuals were risk factors for periodontal disease after multivariate analysis, and a lack of proper sewage and waste disposal facilities were found to increase the risk of H. pylori infection. Although there was no association between periodontal disease and H. pylori seropositivity in the community, a highly-significant association was found between periodontal disease and colonization of H. pylori in dental plaque. Because periodontal disease is associated with the increased colonization of H. pylori, new treatment modalities, such as plaque control measures, should be employed for the complete management of H. pylori-associated gastric disease. © 2014 Wiley Publishing Asia Pty Ltd.

  20. Evaluation of the diagnostic performance and operational characteristics of four rapid immunochromatographic syphilis tests in Burkina Faso.

    Science.gov (United States)

    Bocoum, Fadima Yaya; Ouédraogo, Henri; Tarnagda, Grissoum; Kiba, Alice; Tiendrebeogo, Simon; Bationo, Fabrice; Liestman, Benjamin; Diagbouga, Serge; Zarowsky, Christina; Traoré, Ramata Ouédraogo; Kouanda, Séni

    2015-06-01

    Little information is available on the rapid diagnostic testing for syphilis in Burkina Faso. The objectives of the study were (i) to assess the sensitivity and specificity of four on site rapid tests in comparison with Treponema pallidum haemagglutination assay (TPHA) as a gold standard and (ii) to evaluate the operational characteristics of those tests among health workers in a maternity unit. Four rapid syphilis tests commercially available in Burkina Faso were evaluated using archived serum samples and Treponema pallidum hemagglutination assay (TPHA) as the gold standard. Blood samples were collected between November 2011 and June 2012 from blood donors at the Regional Blood Transfusion Center of Ouagadougou. The sensitivity and specificity of the tests were calculated. Evaluation of operational characteristics such as clarity of pamphlet, complexity of technique, duration, was conducted in a first-level healthcare center with health workers in maternity unit. Alere DetermineTM Syphilis was the most sensitive of the four rapid syphilis tests evaluated. It was followed by SD Bioline Syphilis 3.0, Cypress Diagnostics Syphilis Quick test and Accu-Tell ® Rapid Anti-TP, which was the least sensitive. The four tests demonstrated a good diagnostic specificity for syphilis (95-98%), and healthcare workers found them easy to use. The study allowed confirming the good performance of three of four rapid syphilis tests in Burkina Faso. More research will be conducted to assess the feasibility of introducing selected rapid tests for syphilis in antenatal care services.

  1. A rapid and simple screening method for methamphetamine in urine by radioimmunoassay using a 125I-labeled metahmphetamine derivative

    International Nuclear Information System (INIS)

    Inayama, Seiichi; Tokunaga, Yukiko; Hosoya, Eikichi; Nakadate, Teruo; Niwaguchi, Tetsukichi.

    1980-01-01

    N-Carboxymethylmethamphetamine, a derivative of methamphetamine, was prepared through a new synthetic pathway from ephedrine. Specific antiserum was obtained by immunization of rabbits with the conjugate of N-carboxymethylmethamphetamine with bovine serum albumin. A radioimmunoassay procedure was established using this antibody (specific for methamphetamine) and a 125 I-methamphetamine derivative. A high degree of specificity of the antibody was confirmed by testing for cross-reaction with several methamphetamine analogs, and the sensitivity was found to be 1 ng/tube. The present micro method using radioimmunoassay is highly sensitive, rapid, simple and may be useful as a micro-scale primary screening test for methamphetamine excreted in human urine, for forensic and medical purposes. (author)

  2. Rapid antigen detection test for respiratory syncytial virus diagnosis as a diagnostic tool.

    Science.gov (United States)

    Mesquita, Flávio da Silva; Oliveira, Danielle Bruna Leal de; Crema, Daniela; Pinez, Célia Miranda Nunes; Colmanetti, Thaís Cristina; Thomazelli, Luciano Matsumia; Gilio, Alfredo Elias; Vieira, Sandra Elisabeth; Martinez, Marina Baquerizo; Botosso, Viviane Fongaro; Durigon, Edison Luiz

    The aim of this study was to evaluate the QuickVue ® RSV Test Kit (QUIDEL Corp, CA, USA) as a screening tool for respiratory syncytial virus in children with acute respiratory disease in comparison with the indirect immunofluorescence assay as gold standard. In Brazil, rapid antigen detection tests for respiratory syncytial virus are not routinely utilized as a diagnostic tool, except for the diagnosis of dengue and influenza. The authors retrospectively analyzed 486 nasopharyngeal aspirate samples from children under age 5 with acute respiratory infection, between December 2013 and August 2014, the samples were analyzed by indirect immunofluorescence assay and QuickVue ® RSV Test kit. Samples with discordant results were analyzed by real time PCR and nucleotide sequencing. From 313 positive samples by immunofluorescence assays, 282 (90%) were also positive by the rapid antigen detection test, two were positive only by rapid antigen detection test, 33 were positive only by immunofluorescence assays, and 171 were positive by both methods. The 35 samples with discordant results were analyzed by real time PCR; the two samples positive only by rapid antigen detection test and the five positive only by immunofluorescence assays were also positive by real time PCR. There was no relation between the negativity by QuickVue ® RSV Test and viral load or specific strain. The QuickVue ® RSV Test showed sensitivity of 90%, specificity of 98.8%, predictive positive value of 99.3%, and negative predictive value of 94.6%, with accuracy of 93.2% and agreement κ index of 0.85 in comparison to immunofluorescence assay. This study demonstrated that the QuickVue ® RSV Test Kit can be effective in early detection of Respiratory syncytial virus in nasopharyngeal aspirate and is reliable for use as a diagnostic tool in pediatrics. Copyright © 2016 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  3. Rapid antigen detection test for respiratory syncytial virus diagnosis as a diagnostic tool,

    Directory of Open Access Journals (Sweden)

    Flávio da Silva Mesquita

    Full Text Available Abstract Objective: The aim of this study was to evaluate the QuickVue® RSV Test Kit (QUIDEL Corp, CA, USA as a screening tool for respiratory syncytial virus in children with acute respiratory disease in comparison with the indirect immunofluorescence assay as gold standard. In Brazil, rapid antigen detection tests for respiratory syncytial virus are not routinely utilized as a diagnostic tool, except for the diagnosis of dengue and influenza. Methods: The authors retrospectively analyzed 486 nasopharyngeal aspirate samples from children under age 5 with acute respiratory infection, between December 2013 and August 2014, the samples were analyzed by indirect immunofluorescence assay and QuickVue® RSV Test kit. Samples with discordant results were analyzed by real time PCR and nucleotide sequencing. Results: From 313 positive samples by immunofluorescence assays, 282 (90% were also positive by the rapid antigen detection test, two were positive only by rapid antigen detection test, 33 were positive only by immunofluorescence assays, and 171 were positive by both methods. The 35 samples with discordant results were analyzed by real time PCR; the two samples positive only by rapid antigen detection test and the five positive only by immunofluorescence assays were also positive by real time PCR. There was no relation between the negativity by QuickVue® RSV Test and viral load or specific strain. The QuickVue® RSV Test showed sensitivity of 90%, specificity of 98.8%, predictive positive value of 99.3%, and negative predictive value of 94.6%, with accuracy of 93.2% and agreement κ index of 0.85 in comparison to immunofluorescence assay. Conclusions: This study demonstrated that the QuickVue® RSV Test Kit can be effective in early detection of Respiratory syncytial virus in nasopharyngeal aspirate and is reliable for use as a diagnostic tool in pediatrics.

  4. Comparison of a new rapid plasma reagin card test with the standard rapid plasma reagin 18-mm circle card test and the venereal disease research laboratory slide test for serodiagnosis of syphilis.

    OpenAIRE

    Hambie, E A; Larsen, S A; Perryman, M W; Pettit, D E; Mullally, R L; Whittington, W

    1983-01-01

    The rapid plasma reagin (RPR) card test manufactured by Beckman Instruments, Inc., was compared, qualitatively and quantitatively, with the Venereal Disease Research Laboratory (VDRL) slide test and the standard RPR 18-mm circle card tests for the serodiagnosis of syphilis. Sera from 638 individuals were used in this study. Two pilot lots and two production lots of antigen were submitted by Beckman Instruments, Inc., for evaluation. Qualitative agreement among the three RPR card tests was 98....

  5. Hypervapotron flow testing with rapid prototype models

    International Nuclear Information System (INIS)

    Driemeyer, D.; Hellwig, T.; Kubik, D.; Langenderfer, E.; Mantz, H.; McSmith, M.; Jones, B.; Butler, J.

    1995-01-01

    A flow test model of the inlet section of a three channel hypervapotron plate that has been proposed as a heat sink in the ITER divertor was prepared using a rapid prototyping stereolithography process that is widely used for component development in US industry. An existing water flow loop at the University of Illinois is being used for isothermal flow tests to collect pressure drop data for comparison with proposed vapotron friction factor correlations. Differential pressure measurements are taken, across the test section inlet manifold, the vapotron channel (about a seven inch length), the outlet manifold and the inlet-to-outlet. The differential pressures are currently measured with manometers. Tests were conducted at flow velocities from 1--10 m/s to cover the full range of ITER interest. A tap was also added for a small hypodermic needle to inject dye into the flow channel at several positions to examine the nature of the developing flow field at the entrance to the vapotron section. Follow-on flow tests are planned using a model with adjustable flow channel dimensions to permit more extensive pressure drop data to be collected. This information will be used to update vapotron design correlations for ITER

  6. The Rapid Integration and Test Environment - A Process for Achieving Software Test Acceptance

    OpenAIRE

    Jack, Rick

    2010-01-01

    Proceedings Paper (for Acquisition Research Program) Approved for public release; distribution unlimited. The Rapid Integration and Test Environment (RITE) initiative, implemented by the Program Executive Office, Command, Control, Communications, Computers and Intelligence, Command and Control Program Office (PMW-150), was born of necessity. Existing processes for requirements definition and management, as well as those for software development, did not consistently deliver high-qualit...

  7. The Ausab test - a radioimmunoassay in the solid phase for the detection of antibodies against HBsAg

    International Nuclear Information System (INIS)

    Lange, W.; Koehler, H.; Apodaca, J.

    1974-01-01

    The suitability of a newly developed RIA (Ausab test, Abbott Laboratories) for the detection of antibodies against the Hepatitis B (surface) antigen (HBsAg) has been tested on 1,968 sera of blood donors. Reproducibility test and specificity test were included. During the examination the technique of the Ausab test was changed from the original one-step to the two-step procedure. With the one-step technique 431 of 1,968 sera (21.9%) showed positive reactions. During the test problems concerning the differentiation between positive and negative results were encountered due to high unspecific binding of radioactivity. Positive sera were reexamined employing the two-step technique and only 77.4% of the previously positive reactions could be reproduced. 50 sera that were negative in the one-step test remained negative in the two-step test. Difficulties concerning nonspecific binding of radioactivity as observed with the one-step technique were not ecountered with the two-step procedure. On 92 of the confirmed positive sera a specificity test was run and 90 (97.8%) proved to be specific. A calculated 16.5% of the blood donors in Berlin have to be considered as antibody carriers. Only 6 of the Ausab positive sera were found to give positive reactions in CEP. 3 sera that were initially positive in CEP could neither be confirmed in a repeated CEP nor in the Ausab test. (orig.) [de

  8. The effects of surface treatments on rapid chloride permeability tests

    KAUST Repository

    Yoon, Seyoon

    2012-08-01

    Surface treatments are commonly applied to improve the chloride resistance of concrete structures exposed to saline environments. Information on chloride ingress to surface-treated concrete is mostly provided by application of the rapid chloride permeability test (RCPT); this test is short in duration and provides rapid results. This study presents a numerical formulation, based on the extended Nernst-Plank/Poisson (NPP) equation, to model the effect of the surface treatment on a sample tested by RCPT. Predictions of the model are compared to experimental measurements. The simulations show that the results from RCPT, in terms of ionic profiles and measurement of the electric field, are dependent on the effectiveness of surface treatments. During RCPT, highly effective surface treatments cause both cations and anions to flocculate at the interface between the surface treatment and the concrete, creating a local electric field. Our numerical model includes these phenomena and presents a methodology to obtain more accurate diffusivities of the surface-treated- concrete from RCPT. © 2012 Elsevier B.V. All rights reserved.

  9. The effects of surface treatments on rapid chloride permeability tests

    KAUST Repository

    Yoon, Seyoon; Oh, Sang-gyun; Ha, Juyoung; Monteiro, Paulo M.

    2012-01-01

    Surface treatments are commonly applied to improve the chloride resistance of concrete structures exposed to saline environments. Information on chloride ingress to surface-treated concrete is mostly provided by application of the rapid chloride permeability test (RCPT); this test is short in duration and provides rapid results. This study presents a numerical formulation, based on the extended Nernst-Plank/Poisson (NPP) equation, to model the effect of the surface treatment on a sample tested by RCPT. Predictions of the model are compared to experimental measurements. The simulations show that the results from RCPT, in terms of ionic profiles and measurement of the electric field, are dependent on the effectiveness of surface treatments. During RCPT, highly effective surface treatments cause both cations and anions to flocculate at the interface between the surface treatment and the concrete, creating a local electric field. Our numerical model includes these phenomena and presents a methodology to obtain more accurate diffusivities of the surface-treated- concrete from RCPT. © 2012 Elsevier B.V. All rights reserved.

  10. Anti sperm antibodies detection in infertile patients by radioimmunometry

    International Nuclear Information System (INIS)

    ELnabarawy, F.; Megahed, Y.M.; Tadrous, G.A.; Hamada, T.; Elbadry, A.

    1992-01-01

    Three different methods of testing for anti sperm antibodies were compared: complement cytotoxicity, sperm agglutination, and radiolabelled anti globulin antibody technique, for detection of anti sperm antibodies in serum and secretions (seminal plasma and cervical mucus). Sample from 120 patients with infertility were investigated by the previous three methods. The results of unexplained infertile patients revealed wide variations in figures, concerning the positivity of anti sperm antibody whether in their serum or secretions, by using the cytotoxicity or sperm agglutination tests. Using a specific radiolabelled anti globulin test, a subset of patients (44.9% in the serum of men and 50% in seminal plasma) with IgG anti sperm antibody was identified, and this antibody was present in 65.4% and 78,6% of infertile wives sera and cervical mucus, respectively. Therefore, this test has been used to identify and quantitate antibodies directed toward other human cell surfaces. It was concluded that this radiolabelled method is a clinically useful and a potentially versatile procedure that can be successfully applied to the diagnosis and management of patients with suspected immunologic infertility. 1 fig., 5 tab

  11. Application tests of a new-type LNG rapid gasification unit

    Directory of Open Access Journals (Sweden)

    Ping Yan

    2017-01-01

    Full Text Available Liquefied natural gas (LNG is stored under low temperature and high pressure. It has to be gasified before it is used. Therefore, LNG gasification unit is essential and it is vital to the high-efficiency utilization of LNG. In this paper, a new-type LNG rapid gasification unit was developed. Adopted in this unit are some innovative technologies authorized with the national patent of invention, such as the umbrella-shape gas flow circle unit, the flue gas circulation system and the water feeding system, which help to guarantee its operation safety and increase its operation efficiency. After it was justified in lab test, the unit for industrial application was designed and manufactured and then tested to verify its design rationality. The results show that the new-type LNG rapid gasification unit meets the design requirements in the aspect of efficiency, exhaust gas loss, radiation loss and fuel gas consumption rate; at a load of 1800–2200 m3/h, its efficiency is over 95%; at a load of 1976.0 m3/h which is close to the design value of 2000 m3/h, its efficiency is 96.34% or even up to 2800 m3/h. This new-type LNG rapid gasification unit is adaptable to a large range of loads and can adapt to the rapid increase of external load. Its fuel gas consumption rate is only 1.5%, which is in the range of energy conservation. It presents the advantages of high heating efficiency, rapid startup, high gasification rate, compact structure, small land occupation and invulnerability to the environment, therefore, it is applicable to the middle and small independent regions which cannot be connected to the natural gas supply pipeline networks due to various reasons.

  12. Application of Rapid Prototyping Methods to High-Speed Wind Tunnel Testing

    Science.gov (United States)

    Springer, A. M.

    1998-01-01

    This study was undertaken in MSFC's 14-Inch Trisonic Wind Tunnel to determine if rapid prototyping methods could be used in the design and manufacturing of high speed wind tunnel models in direct testing applications, and if these methods would reduce model design/fabrication time and cost while providing models of high enough fidelity to provide adequate aerodynamic data, and of sufficient strength to survive the test environment. Rapid prototyping methods utilized to construct wind tunnel models in a wing-body-tail configuration were: fused deposition method using both ABS plastic and PEEK as building materials, stereolithography using the photopolymer SL-5170, selective laser sintering using glass reinforced nylon, and laminated object manufacturing using plastic reinforced with glass and 'paper'. This study revealed good agreement between the SLA model, the metal model with an FDM-ABS nose, an SLA nose, and the metal model for most operating conditions, while the FDM-ABS data diverged at higher loading conditions. Data from the initial SLS model showed poor agreement due to problems in post-processing, resulting in a different configuration. A second SLS model was tested and showed relatively good agreement. It can be concluded that rapid prototyping models show promise in preliminary aerodynamic development studies at subsonic, transonic, and supersonic speeds.

  13. High prevalence of HIV p24 antigen among HIV antibody negative prospective blood donors in Ile-Ife, Nigeria.

    Science.gov (United States)

    Japhet, Margaret Oluwatoyin; Adewumi, Moses Olubusuyi; Adesina, Olufisayo Adeyemi; Donbraye, Emmanuel

    2016-01-01

    Blood transfusion service centers in Nigeria screen donated blood for markers of HIV infection using antibody- (Ab) based rapid test and in some centers, positives are re-tested using Ab-based ELISA. Paucity of data exists on p24 antigen prevalence among HIV Ab-negative donors in Nigeria. This study aims at detecting HIV p24 antigen among prospective blood donors in Osun State, Nigeria. Prospective blood donors negative for HIV antibodies using Determine test kit were re-tested using BIORAD GENSCREEN Ultra Ag-Ab ELISA kit, a fourth-generation ELISA kit that detects HIV antibodies/p24 antigen. Of the 169 HIV Ab-negative prospective donors, 10 (5.9%) were positive for HIV p24 antigen and 70% (7/10) of them were in the age range 18-30 years. Results of this study show that blood transfusion is still one of the major routes of HIV transmission in Nigeria and a higher proportion is among youth. Inclusion of p24 antigen testing into the blood donor screening will help reduce transfusion associated HIV in Nigeria if Nucleic Acid Testing (NAT) of all blood donor samples is not affordable; also, HIV enlightenment programs tailored toward youth may help reduce this rate among donors since more young people donate blood in low/middle-income countries than in high-income countries.

  14. Another Piece of the Antibody Puzzle: Observations from the HALT study\\.

    Science.gov (United States)

    Snyder, Laurie D; Tinckam, Kathryn J

    2018-06-04

    In the rapidly evolving domain of clinical transplantation immunobiology, the interrogation and interpretation of HLA antibodies and their associated clinical consequences are in the spotlight. In lung transplant, HLA antibodies, in particular donor specific antibodies (DSA), are a determining component of the lung transplant antibody mediated rejection (AMR) definition (1). DSA after lung transplant are widely regarded as poor prognosticator, though sparse data to date necessitate ongoing discourse and continued investigation into incidence, timing and treatment. Prior studies reported a wide range of DSA incidence with differing consequences on a background of highly variable timing, methods, antibody analytic strategies and clinical definitions. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  15. Monoclonal antibodies and Fc fragments for treating solid tumors

    Directory of Open Access Journals (Sweden)

    Eisenbeis AM

    2012-01-01

    Full Text Available Andrea M Eisenbeis, Stefan J GrauDepartment of Neurosurgery, University Hospital of Cologne, Cologne, GermanyAbstract: Advances in biotechnology, better understanding of pathophysiological processes, as well as the identification of an increasing number of molecular markers have facilitated the use of monoclonal antibodies and Fc fragments in various fields in medicine. In this context, a rapidly growing number of these substances have also emerged in the field of oncology. This review will summarize the currently approved monoclonal antibodies used for the treatment of solid tumors with a focus on their clinical application, biological background, and currently ongoing trials.Keywords: targeted therapy, monoclonal antibodies, cancer, biological therapy

  16. [The social marketing models and policy advices for HIV rapid testing initiated by non-govermental organization].

    Science.gov (United States)

    Liu, H; Cai, L P; Xue, H; Zhao, Y; Wu, D; Zhang, D P; Yin, W Y; Sun, J P

    2016-10-06

    Currently, a growing number of community-based organizations are providing rapid HIV testing service in various forms, some people with specific needs also purchase HIV rapid test papers through online sales channels, those imply that the demand of HIV self-test is in increasing year by year.In this paper, aims to understand the current situation of HIV rapid test led by CBOs and the approach, strategies and results of social marketing by means of expert interviews and site visits. Hope to illustrate the current situation, and make recommendations for future work.

  17. Duration of detection of anti-BmR1 IgG4 antibodies after mass-drug administration (MDA) in Sarawak, Malaysia.

    Science.gov (United States)

    Noordin, R; Muhi, J; Md Idris, Z; Arifin, N; Kiyu, A

    2012-03-01

    The detection rates of brugian filariasis in three regions of Sarawak namely Central, North and South after three courses of mass drug administration (MDA) from year 2004 to 2006 was investigated. A recombinant BmR1 antigen-based IgG4 detection test, named Brugia Rapid and night blood smear for microfilaria (mf) detection were used. All three regions recorded a sharp fall in mf positive rates after a year post-MDA. Meanwhile Brugia Rapid positive rates declined more gradually to 3.8% and 5.6% of the pre-MDA levels in the Central and North regions, respectively. This study showed that in filariasis endemic areas in Sarawak, anti-filarial IgG4 antibodies to BmR1, as detected by the Brugia Rapid test, were positive for one to two years after mf disappearance.

  18. Radioimmunological proof of thyroglobulin antibodies in humans by the use of a double antibody method

    International Nuclear Information System (INIS)

    Waller, V.

    1982-01-01

    Thyroid antibodies, especially thyroglobulin antibodies, allow themselves to be proven with the double antibody method, in competitive radio binding assays and with the solid phase technique. These methods offer advantages relative to sensitivity and quantifiability. In this work a sensitive radioimmunoassay as a double antibody method was worked out whereby a 125 I-thyroglobulin/thyroglobulin antibody immune complex was precipitated out using anti-human immunoglobulin. The measured results from the radioimmunoassay show a good correlation with the results of the immune histological findings. A high to very high Tg antibody level occurs with autoimmune thyroiditis (80%), primary hypothyroidism (74%) and hyperthyroidism (70%). The control values with healthy people came to less than 5% specific binding. In correlation with the results of other authors this method is advantageous relative to test start and evaluation procedures. (orig.) [de

  19. [Evaluation of a rapid trehalase test for the identification of Candida glabrata].

    Science.gov (United States)

    Kirdar, Sevin; Gültekin, Berna; Evcil, Gonca; Ozkütük, Aydan; Sener, Asli Gamze; Aydin, Neriman

    2009-04-01

    Candida species which cause local infections, may also lead to fatal systemic infections. The increasing incidence of non-albicans Candida, especially fluconazole susceptible or resistant dose-dependent C. glabrata, increased the importance of rapid and accurate species level identification for Candida. Rapid and correct identification of C. glabrata is essential for the initiation of the appropriate antifungal therapy. This study was conducted to evaluate the performance of the rapid trehalase test in the diagnosis of C. glabrata isolates. A total of 173 Candida strains isolated from various clinical specimens and identified according to germ tube test, growth on cornmeal Tween 80 agar and the colony morphologies on Mast-CHROMagar Candida medium (Mast Diagnostics, UK), were included to the study. The identification of non-albicans Candida species were also confirmed by API 20CAUX (BioMerieux, France) system. Accordingly 86 (50%) of the isolates were identified as C. glabrata, 48 (28%) C. albicans, 17 (10%) C. krusei, 13 (8%) C. tropicalis, 5 (3%) C. parapsilosis, 3 (2%) C. kefyr and 1 (1%) Cutilis. In order to detect the presence of trehalase enzyme in Condida strains, all isolates were grown on Sabouraud dextrose agar containing 4% glucose and then one yeast colony was emulsified in 50 microl of citrate buffer containing 4% (wt/vol) trehalose for 3 h at 37 degrees C. Presence of glucose which emerged after the action of trehalase on trehalose, was detected by a commercial "urinary glucose detection dipstick" (Spinreacta, Spain). All C. glabrata strains yielded positive result by trehalase test. None C. glabrata isolates were found negative by trehalase test except for one strain of C. tropicalis. In this study, the trehalase test allowed identification of C. globrata with 100% sensitivity and 98.9% specificity. It was concluded that trehalase test is a rapid, cost-effective and simple test that can be used for the accurate identification of C. glabrata.

  20. Naturally acquired Lawsonia intracellularis infection in pigs studied from weaning to slaughter by indirect immunofluorescence antibody test and polymerase chain reaction on faeces

    DEFF Research Database (Denmark)

    Jensen, Tim Kåre; Vigre, Håkan; Sørensen, Vibeke

    2005-01-01

    by immunofluorescence antibody test compared to 24% by immunohistochemistry on ileal samples. Thus, applied at the time of slaughter the antibody test appeared to be a highly sensitive ante-mortem diagnostic tool for identifying L. intracelluaris exposed pigs with or without current proliferative enteropathy. (c) 2004......The course of naturally acquired Lawsonia intracellularis infection was studied in 41 pigs by testing blood and faeces samples collected four to seven times from before weaning to slaughter 5 months old. At slaughter, a sample of ileum was taken for histopathology. In the first sampling when...... later on shed and/or were seropositive for L. intracellularis. The lowest prevalence of L. intracellularis was observed in 6-13 weeks old pigs and it seemed as though L. intracellularis in early infected pigs only activates a minor antibody response. At slaughter 66% of the pigs were found positive...

  1. Antibody-mediated phagocytosis contributes to the anti-tumor activity of the therapeutic antibody daratumumab in lymphoma and multiple myeloma

    DEFF Research Database (Denmark)

    Overdijk, M. B.; Verploegen, S.; Bogels, M.

    2015-01-01

    Daratumumab (DARA) is a human CD38-specific IgG1 antibody that is in clinical development for the treatment of multiple myeloma (MM). The potential for IgG1 antibodies to induce macrophage-mediated phagocytosis, in combination with the known presence of macrophages in the tumor microenvironment...... in MM and other hematological tumors, led us to investigate the contribution of antibody-dependent, macrophage-mediated phagocytosis to DARA's mechanism of action. Live cell imaging revealed that DARA efficiently induced macrophage-mediated phagocytosis, in which individual macrophages rapidly...... and sequentially engulfed multiple tumor cells. DARA-dependent phagocytosis by mouse and human macrophages was also observed in an in vitro flow cytometry assay, using a range of MM and Burkitt's lymphoma cell lines. Phagocytosis contributed to DARA's anti-tumor activity in vivo, in both a subcutaneous...

  2. A large-scale radiometric micro-quantitative complement fixation test for serum antibody titration

    International Nuclear Information System (INIS)

    Bengali, Z.H.; Levine, P.H.; Das, S.R.

    1980-01-01

    A micro-quantitative complement fixation (CF) procedure based on 51 Cr release is described. The method employs 50% hemolysis as end point and the alternation equation to calculate the amount of complement involved in the hemolytic reaction. Compared to the conventional CF tests, the radiometric procedure described here is very precise and consistently reproducible. Also, since only 3 4-fold dilutions of sera are used for the titration of antibodies over a wide range of concentrations, the test is very concise and is economical to perform. Its format is amenable to automation and computerization. This radioimetric CF procedure is thus most useful for large-scale immunological research and epidemiological surveilance studies. (Auth.)

  3. Reliable cloning of functional antibody variable domains from hybridomas and spleen cell repertoires employing a reengineered phage display system.

    Science.gov (United States)

    Krebber, A; Bornhauser, S; Burmester, J; Honegger, A; Willuda, J; Bosshard, H R; Plückthun, A

    1997-02-14

    A prerequisite for the use of recombinant antibody technologies starting from hybridomas or immune repertoires is the reliable cloning of functional immunoglobulin genes. For this purpose, a standard phage display system was optimized for robustness, vector stability, tight control of scFv-delta geneIII expression, primer usage for PCR amplification of variable region genes, scFv assembly strategy and subsequent directional cloning using a single rare cutting restriction enzyme. This integrated cloning, screening and selection system allowed us to rapidly obtain antigen binding scFvs derived from spleen-cell repertoires of mice immunized with ampicillin as well as from all hybridoma cell lines tested to date. As representative examples, cloning of monoclonal antibodies against a his tag, leucine zippers, the tumor marker EGP-2 and the insecticide DDT is presented. Several hybridomas whose genes could not be cloned in previous experimental setups, but were successfully obtained with the present system, expressed high amounts of aberrant heavy and light chain mRNAs, which were amplified by PCR and greatly exceeded the amount of binding antibody sequences. These contaminating variable region genes were successfully eliminated by employing the optimized phage display system, thus avoiding time consuming sequencing of non-binding scFv genes. To maximize soluble expression of functional scFvs subsequent to cloning, a compatible vector series to simplify modification, detection, multimerization and rapid purification of recombinant antibody fragments was constructed.

  4. Magnesium Test

    Science.gov (United States)

    ... PF4 Antibody Hepatitis A Testing Hepatitis B Testing Hepatitis C Testing HER2/neu Herpes Testing High-sensitivity C-reactive Protein (hs-CRP) Histamine Histone Antibody HIV Antibody and HIV Antigen (p24) HIV Antiretroviral Drug Resistance Testing, Genotypic HIV Viral Load HLA Testing HLA- ...

  5. Lipase Test

    Science.gov (United States)

    ... PF4 Antibody Hepatitis A Testing Hepatitis B Testing Hepatitis C Testing HER2/neu Herpes Testing High-sensitivity C-reactive Protein (hs-CRP) Histamine Histone Antibody HIV Antibody and HIV Antigen (p24) HIV Antiretroviral Drug Resistance Testing, Genotypic HIV Viral Load HLA Testing HLA- ...

  6. Rubella Test

    Science.gov (United States)

    ... PF4 Antibody Hepatitis A Testing Hepatitis B Testing Hepatitis C Testing HER2/neu Herpes Testing High-sensitivity C-reactive Protein (hs-CRP) Histamine Histone Antibody HIV Antibody and HIV Antigen (p24) HIV Antiretroviral Drug Resistance Testing, Genotypic HIV Viral Load HLA Testing HLA- ...

  7. Mono Test

    Science.gov (United States)

    ... PF4 Antibody Hepatitis A Testing Hepatitis B Testing Hepatitis C Testing HER2/neu Herpes Testing High-sensitivity C-reactive Protein (hs-CRP) Histamine Histone Antibody HIV Antibody and HIV Antigen (p24) HIV Antiretroviral Drug Resistance Testing, Genotypic HIV Viral Load HLA Testing HLA- ...

  8. AMA Test

    Science.gov (United States)

    ... PF4 Antibody Hepatitis A Testing Hepatitis B Testing Hepatitis C Testing HER2/neu Herpes Testing High-sensitivity C-reactive Protein (hs-CRP) Histamine Histone Antibody HIV Antibody and HIV Antigen (p24) HIV Antiretroviral Drug Resistance Testing, Genotypic HIV Viral Load HLA Testing HLA- ...

  9. Radioiodination of monoclonal antibody intact anti-CEA

    International Nuclear Information System (INIS)

    Okada, H.; Souza, I.T.T.; Silva, C.P.G.

    1990-11-01

    The purpose of this study is to examine a convenient system that can be used to iodinate monoclonal antibodies which is rapid, simple, efficient and reproducible, and which can be accomplished in radiopharmaceutical laboratories. It is important to remember that antibodies are sensitive biochemicals, subject to losses of the activity that is essential to their mode of action, namely the ability to bind specific antigen. The advent of solid phase iodination agents has greatly expanded the range of gentle iodination techniques available for iodinating sensitive biological materials. The agent most widely used is the Iodogen (1,3,4,6 tetrachloro-3a-6a diphenylglycoluril) method. Anti-CEA 4C sub(11) IgG sub(2a,k) (prepared in the Ludwig Institute-Sao Paulo-Brazil ) is used as model to evaluate the Iodogen methodology. The miniature chromatographic system, also rapid, accurate, simple, efficient was elaborated to determine the labelling efficiency incorporation of iodine into immunoglobulin, and the radiochemical purity of sup(131)I-anti-CEA. (author)

  10. HIV Rapid Testing in a VA Emergency Department Setting: Cost Analysis at 5 Years.

    Science.gov (United States)

    Knapp, Herschel; Chan, Kee

    2015-07-01

    To conduct a comprehensive cost-minimization analysis to comprehend the financial attributes of the first 5 years of an implementation wherein emergency department (ED) registered nurses administered HIV oral rapid tests to patients. A health science research implementation team coordinated with ED stakeholders and staff to provide training, implementation guidelines, and support to launch ED registered nurse-administered HIV oral rapid testing. Deidentified quantitative data were gathered from the electronic medical records detailing quarterly HIV rapid test rates in the ED setting spanning the first 5 years. Comprehensive cost analyses were conducted to evaluate the financial impact of this implementation. At 5 years, a total of 2,620 tests were conducted with a quarterly mean of 131 ± 81. Despite quarterly variability in testing rates, regression analysis revealed an average increase of 3.58 tests per quarter. Over the course of this implementation, Veterans Health Administration policy transitioned from written to verbal consent for HIV testing, serving to reduce the time and cost(s) associated with the testing process. Our data indicated salient health outcome benefits for patients with respect to the potential for earlier detection, and associated long-run cost savings. Copyright © 2015. Published by Elsevier Inc.

  11. The Role of Anti-Drug Antibodies in the Pharmacokinetics, Disposition, Target Engagement, and Efficacy of a GITR Agonist Monoclonal Antibody in Mice.

    Science.gov (United States)

    Brunn, Nicholas D; Mauze, Smita; Gu, Danling; Wiswell, Derek; Ueda, Roanna; Hodges, Douglas; Beebe, Amy M; Zhang, Shuli; Escandón, Enrique

    2016-03-01

    Administration of biologics to enhance T-cell function is part of a rapidly growing field of cancer immunotherapy demonstrated by the unprecedented clinical success of several immunoregulatory receptor targeting antibodies. While these biologic agents confer significant anti-tumor activity through targeted immune response modulation, they can also elicit broad immune responses potentially including the production of anti-drug antibodies (ADAs). DTA-1, an agonist monoclonal antibody against GITR, is a highly effective anti-tumor treatment in preclinical models. We demonstrate that repeated dosing with murinized DTA-1 (mDTA-1) generates ADAs with corresponding reductions in drug exposure and engagement of GITR on circulating CD3(+) CD4(+) T cells, due to rapid hepatic drug uptake and catabolism. Mice implanted with tumors after induction of preexisting mDTA-1 ADA show no anti-tumor efficacy when given 3 mg/kg mDTA-1, an efficacious dose in naive mice. Nonetheless, increasing mDTA-1 treatment to 30 mg/kg in ADA-positive mice restores mDTA-1 exposure and GITR engagement on circulating CD3(+) CD4(+) T cells, thereby partially restoring anti-tumor efficacy. Formation of anti-mDTA-1 antibodies and changes in drug exposure and disposition does not occur in GITR(-/-) mice, consistent with a role for GITR agonism in humoral immunity. Finally, the administration of muDX400, a murinized monoclonal antibody against the checkpoint inhibitor PD-1, dosed alone or combined with mDTA-1 did not result in reduced muDX400 exposure, nor did it change the nature of the anti-mDTA-1 response. This indicates that anti-GITR immunogenicity may not necessarily impact the pharmacology of coadministered monoclonal antibodies, supporting combination immunomodulatory strategies. Copyright © 2016 by The American Society for Pharmacology and Experimental Therapeutics.

  12. Specificity of anti-phospholipid antibodies in infectious mononucleosis: a role for anti-cofactor protein antibodies

    Science.gov (United States)

    Sorice, M; Pittoni, V; Griggi, T; Losardo, A; Leri, O; Magno, M S; Misasi, R; Valesini, G

    2000-01-01

    The antigen specificity of anti-phospholipid antibodies in infectious mononucleosis (IM) was studied using ELISA for the detection of anti-β2-glycoprotein I (β2-GPI), anti-annexin V, anti-protein S and anti-prothrombin antibodies and TLC immunostaining for the detection of anti-phospholipid antibodies. This technique enabled us to look at antibodies reacting to ‘pure’ phospholipid antigens in the absence of protein contamination. Sera from 46 patients with IM, 18 with systemic lupus erythematosus (SLE), 21 with primary anti-phospholipid antibody syndrome (PAPS), 50 with Helicobacter pylori infection and 30 healthy blood donors were tested. This study highlights anti-phospholipid antibodies in patients with IM as specific ‘pure’ anti-cardiolipin antibodies, while in PAPS and SLE patients anti-phosphatidylserine and anti-phosphatidylethanolamine antibodies were also found. This investigation also shows that the anti-cardiolipin antibodies found in IM can be present with anti-cofactor protein antibodies. The higher prevalence of anti-cofactor antibodies found in IM sera than in Helicobacter pylori sera may be due to the immunostimulatory effect and/or the polyclonal activation often observed in course of Epstein–Barr virus infection. However, anti-β2-GPI and, to a lesser extent, anti-prothrombin antibodies occur with a significantly lower prevalence in IM than in PAPS patients. This finding suggests that these antibodies should be regarded as the expression of the broad autoimmune syndrome involving the phospholipid-binding plasma proteins. PMID:10792380

  13. Detection of antibody responses by using haemagglutination inhibiton test and the protection titer of avian influenza virus H5N1 subtype

    Directory of Open Access Journals (Sweden)

    Risa Indriani

    2004-10-01

    Full Text Available Study on the detection of antibody responses using haemagglutination inhibition (HI test and the protection titer to Avian influenza (AI virus H5N1 subtype local isolate has been conducted at the Research Institute for Veterinary Science (RIVS. A total number of 50 village chicken (10 chicken served as un-injected controls and 30 quail were injected intramuscularly with inactivated virus of AI H5N1 subtype local isolate. Serum samples were collected 3 weeks after injection and were tested using haemagglutination inhibition tests. The correlation between antibody titer and its protection to AI virus H5N1 local isolate were measured by challenging the birds with AI virus H5N1 local isolate The HI test was then used to determine field serum samples. A total number of 48 village chicken from three (3 Districts (Bekasi, Tangerang and Bogor and 96 quails from two (2 farms in District of Sukabumi which were all vaccinated with commercial AI adjuvant vaccine were sampled. The study revealed that village chicken and quails showed antibody responses after 3 weeks vaccination and that titer of ≥ 3 log 2 was able to protect chicken and quails when they were challenged with local isolate virus. Based on this result, village chicken field samples from Districts of Tangerang, Bekasi and Bogor showed antibody titer which will protect 50, 100 and 85% of the flocks respectively. While quail field samples from Farm I and Farm II in District of Sukabumi showed antibody titer which will protect 60-100% and 0-80% of the flocks respectively. It is concluded that the study has successfully measured antibody titer to AI virus H5N1 subtype which protect village chicken and quails from local isolate virus challenge so that the results will be used to analyze field serum samples after vaccination program to eradicate AI from Indonesia.

  14. Repeat confirmatory testing for persons with discordant whole blood and oral fluid rapid HIV test results: findings from post marketing surveillance.

    Directory of Open Access Journals (Sweden)

    Laura G Wesolowski

    Full Text Available BACKGROUND: Reactive oral fluid and whole blood rapid HIV tests must be followed with a confirmatory test (Western blot (WB, immunofluorescent assay (IFA or approved nucleic acid amplification test (NAAT. When the confirmatory result is negative or indeterminate (i.e. discordant with rapid result, repeat confirmatory testing should be conducted using a follow-up specimen. Previous reports have not described whether repeat testing adequately resolves the HIV-infection status of persons with discordant results. METHODOLOGY: Post-marketing surveillance was conducted in 368 testing sites affiliated with 14 state and 2 city health departments from August 11, 2004 to June 30, 2005 and one health department through December 31, 2005. For persons with discordant results, data were collected on demographics, risk behaviors, HIV test results and specimen types. Persons with repeat confirmatory results were classified as HIV-infected or uninfected. Regression models were created to assess risk factors for not having repeat testing. PRINCIPAL FINDINGS: Of 167,371 rapid tests conducted, 2589 (1.6% were reactive: of these, 2417 (93% had positive WB/IFA, 172 (7% had negative or indeterminate WB/IFA. Of 89/172 (52% persons with a repeat confirmatory test: 17 (19% were HIV-infected, including 3 with indeterminate WB and positive NAAT; 72 (81% were uninfected, including 12 with repeat indeterminate WB. Factors associated with HIV-infection included having an initial indeterminate WB/IFA (vs. negative (p<0.001 and having an initial oral fluid WB (vs. serum (p<0.001. Persons who had male-female sex (vs. male-male sex were at increased risk for not having a repeat test [adjusted OR 2.6, 95% CI (1.3, 4.9]. CONCLUSIONS: Though only half of persons with discordant results had repeat confirmatory testing, of those who did, nearly one in five were HIV-infected. These findings underscore the need for rapid HIV testing programs to increase repeat confirmatory testing for

  15. Application of the Ceditest FMDV type O and FMDV-NS enzyme-linked immunosorbent assays for detection of antibodies against Foot-and-mouth disease virus in selected livestock and wildlife species in Uganda

    DEFF Research Database (Denmark)

    Ayebazibwe, Chrisostom; Mwiine, Frank Norbert; Balinda, Sheila Nina

    2012-01-01

    Diagnosis and control of Foot-and-mouth disease virus (FMDV) requires rapid and sensitive diagnostic tests. Two antibody enzyme-linked immunosorbent assay (ELISA) kits, Ceditest FMDV-NS for the detection of antibodies against the nonstructural proteins of all FMDV serotypes and Ceditest FMDV type O......, and selected samples were tested not only in serotype-specific ELISAs for antibodies against primarily FMDV serotype O, but also against other serotypes. The FMDV-NS assay detected far more positive samples (93%) than the FMDV type O assay (30%) in buffalo (P ... the South African Territories (SAT) serotypes, while the seroprevalence was generally comparable in cattle with antibodies against serotype O elicited by infection and/or vaccination. However, some districts had higher seroprevalence using the FMDV type O assay indicating vaccination without infection...

  16. Fed-batch CHO cell culture for lab-scale antibody production

    DEFF Research Database (Denmark)

    Fan, Yuzhou; Ley, Daniel; Andersen, Mikael Rørdam

    2017-01-01

    Fed-batch culture is the most commonly used upstream process in industry today for recombinant monoclonal antibody production using Chinese hamster ovary cells. Developing and optimizing this process in the lab is crucial for establishing process knowledge, which enable rapid and predictable tech......-transfer to manufacturing scale. In this chapter, we will describe stepwise how to carry out fed-batch CHO cell culture for lab-scale antibody production....

  17. Efficient generation of monoclonal antibodies from single rhesus macaque antibody secreting cells.

    Science.gov (United States)

    Meng, Weixu; Li, Leike; Xiong, Wei; Fan, Xuejun; Deng, Hui; Bett, Andrew J; Chen, Zhifeng; Tang, Aimin; Cox, Kara S; Joyce, Joseph G; Freed, Daniel C; Thoryk, Elizabeth; Fu, Tong-Ming; Casimiro, Danilo R; Zhang, Ningyan; A Vora, Kalpit; An, Zhiqiang

    2015-01-01

    Nonhuman primates (NHPs) are used as a preclinical model for vaccine development, and the antibody profiles to experimental vaccines in NHPs can provide critical information for both vaccine design and translation to clinical efficacy. However, an efficient protocol for generating monoclonal antibodies from single antibody secreting cells of NHPs is currently lacking. In this study we established a robust protocol for cloning immunoglobulin (IG) variable domain genes from single rhesus macaque (Macaca mulatta) antibody secreting cells. A sorting strategy was developed using a panel of molecular markers (CD3, CD19, CD20, surface IgG, intracellular IgG, CD27, Ki67 and CD38) to identify the kinetics of B cell response after vaccination. Specific primers for the rhesus macaque IG genes were designed and validated using cDNA isolated from macaque peripheral blood mononuclear cells. Cloning efficiency was averaged at 90% for variable heavy (VH) and light (VL) domains, and 78.5% of the clones (n = 335) were matched VH and VL pairs. Sequence analysis revealed that diverse IGHV subgroups (for VH) and IGKV and IGLV subgroups (for VL) were represented in the cloned antibodies. The protocol was tested in a study using an experimental dengue vaccine candidate. About 26.6% of the monoclonal antibodies cloned from the vaccinated rhesus macaques react with the dengue vaccine antigens. These results validate the protocol for cloning monoclonal antibodies in response to vaccination from single macaque antibody secreting cells, which have general applicability for determining monoclonal antibody profiles in response to other immunogens or vaccine studies of interest in NHPs.

  18. 9 CFR 147.3 - The stained-antigen, rapid, whole-blood test. 3

    Science.gov (United States)

    2010-01-01

    ...-blood test. 3 147.3 Section 147.3 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE... Blood Testing Procedures § 147.3 The stained-antigen, rapid, whole-blood test. 3 3 The procedure described is a modification of the method reported by Schaffer, MacDonald, Hall, and Bunyea, Jour. Amer. Vet...

  19. Clinical validation of a point-of-care multiplexed in vitro immunoassay using monoclonal antibodies (the MSD influenza test) in four hospitals in Vietnam.

    Science.gov (United States)

    van Doorn, H Rogier; Kinh, Nguyen van; Tuan, Ha Manh; Tuan, Tran Anh; Minh, Ngo Ngoc Quang; Bryant, Juliet E; Hang, Vu thi Ty; Uyen, Le thi Tham; Thinh, Le Quoc; Anh, Tran thi Ngoc; Lan, Nguyen Phu Huong; Trung, Nguyen Vu; Taylor, Walter; Merson, Laura; Wertheim, Heiman F L; Farrar, Jeremy; Wolbers, Marcel; Chau, Nguyen van Vinh; de Jong, Menno D

    2012-05-01

    Point-of-care (POC) diagnostic tests for influenza can considerably shorten the time to clinical decision making. An investigational POC test based on a multiplexed immunoassay was developed by Meso Scale Diagnostics, LLC (MSD), with the objective to make a more sensitive rapid test that can also subtype influenza A viruses (1977 H1, H3, and H5). Between February and November 2010, we conducted a prospective multicenter study at four hospitals in Vietnam and compared the performance of this test to that of the WHO/CDC real-time reverse transcriptase PCR (RT-PCR) on nasal and throat swab specimens from patients presenting with influenza-like illness. Five hundred sixty-three adults and children with a median age of 25 months were enrolled. Sensitivity and specificity of the test with combined results from nasal and throat swab samples were 74.0% (131/177) and 99.7% (351/352), respectively, compared to RT-PCR. The POC test was as sensitive for influenza virus B as for influenza virus A (74.4% [64/86] versus 73.6% [67/91]). The positivity rate was associated with lower cycle threshold values (a marker for higher viral loads), sample type (73.6% for nasal swab versus 52.4% for throat swab), and younger age. A total of 210 (18.7%) out of 1,126 MSD tests failed, and for 34 (6%) of patients, both test samples failed (these were excluded from the performance analysis). Subtyping could be assessed only for influenza virus A/H3N2, as 1977 H1N1 was not circulating at the time and no H5N1-infected patients were enrolled, and was successful only in 9/54 patients infected with H3 influenza virus who had a positive POC test result for influenza virus A. This novel POC test provided highly sensitive detection of influenza viruses A and B compared to the reported sensitivities of other rapid tests. However, 18.7% of tests failed for technical reasons and subtyping for H3 was poor. Drawbacks to the technology include the requirement for a dedicated reader instrument and the need for

  20. Rapid Magnetic Nanobiosensor for the detection of Serratia marcescen

    Science.gov (United States)

    Aljabali, Alaa A. A.; Hussein, Emad; Aljumaili, Omar; Zoubi, Mazhar Al; Altrad, Bahaa; Albatayneh, Khaled; Al-razaq, Mutaz A. Abd

    2018-02-01

    The development of rapid, sensitive, accurate and reliable bacterial detection methods are of keen interest to ensure food safety and hospital security. Therefore, the development of a fast, specific, low-cost and trusted methods is in high demand. Magnetic nanoparticles with their unique material properties have been utilized as a tool for pathogen detection. Here, we present a novel iron oxide nanoparticles labeled with specific targeting antibodies to improve specificity and extend the use of nanoparticles as nanosensors. The results indicated that antibody labeled iron oxide platform that binds specifically to Serriata marcescenst in a straightforward method is very specific and sensitive. The system is capable of rapid and specific detection of various clinically relevant bacterial species, with sensitivity down to single bacteria. The generic platform could be used to identify pathogens for a variety of applications rapidly.

  1. Analytical Validation of the ReEBOV Antigen Rapid Test for Point-of-Care Diagnosis of Ebola Virus Infection.

    Science.gov (United States)

    Cross, Robert W; Boisen, Matthew L; Millett, Molly M; Nelson, Diana S; Oottamasathien, Darin; Hartnett, Jessica N; Jones, Abigal B; Goba, Augustine; Momoh, Mambu; Fullah, Mohamed; Bornholdt, Zachary A; Fusco, Marnie L; Abelson, Dafna M; Oda, Shunichiro; Brown, Bethany L; Pham, Ha; Rowland, Megan M; Agans, Krystle N; Geisbert, Joan B; Heinrich, Megan L; Kulakosky, Peter C; Shaffer, Jeffrey G; Schieffelin, John S; Kargbo, Brima; Gbetuwa, Momoh; Gevao, Sahr M; Wilson, Russell B; Saphire, Erica Ollmann; Pitts, Kelly R; Khan, Sheik Humarr; Grant, Donald S; Geisbert, Thomas W; Branco, Luis M; Garry, Robert F

    2016-10-15

     Ebola virus disease (EVD) is a severe viral illness caused by Ebola virus (EBOV). The 2013-2016 EVD outbreak in West Africa is the largest recorded, with >11 000 deaths. Development of the ReEBOV Antigen Rapid Test (ReEBOV RDT) was expedited to provide a point-of-care test for suspected EVD cases.  Recombinant EBOV viral protein 40 antigen was used to derive polyclonal antibodies for RDT and enzyme-linked immunosorbent assay development. ReEBOV RDT limits of detection (LOD), specificity, and interference were analytically validated on the basis of Food and Drug Administration (FDA) guidance.  The ReEBOV RDT specificity estimate was 95% for donor serum panels and 97% for donor whole-blood specimens. The RDT demonstrated sensitivity to 3 species of Ebolavirus (Zaire ebolavirus, Sudan ebolavirus, and Bundibugyo ebolavirus) associated with human disease, with no cross-reactivity by pathogens associated with non-EBOV febrile illness, including malaria parasites. Interference testing exhibited no reactivity by medications in common use. The LOD for antigen was 4.7 ng/test in serum and 9.4 ng/test in whole blood. Quantitative reverse transcription-polymerase chain reaction testing of nonhuman primate samples determined the range to be equivalent to 3.0 × 10 5 -9.0 × 10 8 genomes/mL.  The analytical validation presented here contributed to the ReEBOV RDT being the first antigen-based assay to receive FDA and World Health Organization emergency use authorization for this EVD outbreak, in February 2015. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.

  2. Sensitive and rapid immunoassay for parathyroid hormone using magnetic particle labels and magnetic actuation.

    Science.gov (United States)

    Dittmer, W U; de Kievit, P; Prins, M W J; Vissers, J L M; Mersch, M E C; Martens, M F W C

    2008-09-30

    A rapid method for the sensitive detection of proteins using actuated magnetic particle labels, which are measured with a giant magneto-resistive (GMR) biosensor, is described. The technique involves a 1-step sandwich immunoassay with no fluid replacement steps. The various assay binding reactions as well as the bound/free separation are entirely controlled by magnetic forces induced by electromagnets above and below the sensor chip. During the assay, particles conjugated with tracer antibodies are actuated through the sample for target capture, and rapidly brought to the sensor surface where they bind to immobilized capture antibodies. Weakly or unbound labels are removed with a magnetic force oriented away from the GMR sensor surface. For the measurement of parathyroid hormone (PTH), a detection limit in the 10 pM range is obtained with a total assay time of 15 min when 300 nm particles are used. The same sensitivity can be achieved in 5 min when 500 nm particles are used. If 500 nm particles are employed in a 15-minute assay, then 0.8 pM of PTH is detectable. The low sample volume, high analytical performance and high speed of the test coupled with the compact GMR biosensor make the system especially suitable for sensitive testing outside of laboratory environments.

  3. Rapid diagnostic tests for typhoid and paratyphoid (enteric) fever

    Science.gov (United States)

    Wijedoru, Lalith; Mallett, Sue; Parry, Christopher M

    2017-01-01

    Background Differentiating both typhoid (Salmonella Typhi) and paratyphoid (Salmonella Paratyphi A) infection from other causes of fever in endemic areas is a diagnostic challenge. Although commercial point-of-care rapid diagnostic tests (RDTs) for enteric fever are available as alternatives to the current reference standard test of blood or bone marrow culture, or to the widely used Widal Test, their diagnostic accuracy is unclear. If accurate, they could potentially replace blood culture as the World Health Organization (WHO)-recommended main diagnostic test for enteric fever. Objectives To assess the diagnostic accuracy of commercially available rapid diagnostic tests (RDTs) and prototypes for detecting Salmonella Typhi or Paratyphi A infection in symptomatic persons living in endemic areas. Search methods We searched the Cochrane Infectious Diseases Group Specialized Register, MEDLINE, Embase, Science Citation Index, IndMED, African Index Medicus, LILACS, ClinicalTrials.gov, and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) up to 4 March 2016. We manually searched WHO reports, and papers from international conferences on Salmonella infections. We also contacted test manufacturers to identify studies. Selection criteria We included diagnostic accuracy studies of enteric fever RDTs in patients with fever or with symptoms suggestive of enteric fever living in endemic areas. We classified the reference standard used as either Grade 1 (result from a blood culture and a bone marrow culture) or Grade 2 (result from blood culture and blood polymerase chain reaction, or from blood culture alone). Data collection and analysis Two review authors independently extracted the test result data. We used a modified QUADAS-2 extraction form to assess methodological quality. We performed a meta-analysis when there were sufficient studies for the test and heterogeneity was reasonable. Main results Thirty-seven studies met the inclusion

  4. Determination of antinucleic factors and anti-DNA antibodies with immunefluorescence, radioimmunoassay and latex-test

    International Nuclear Information System (INIS)

    Lemmel, E.M.; Hoffmann, R.; Botzenhardt, U.; Mainz Univ.

    1976-01-01

    The results obtained with the 3 test methods are not completely equal. This is, on the one hand, based on the fact that at least in the fluorescence test other antibodies than in the DNS-compound test are also detected. Quantitatively, however, the two tests show a good correlation to the progress of the illness; strong positive DNA-compound is practically only found in SLE. The authors were able to prove that the addition of purified C1 or C1q components of the complementary system to the test can result in a DNA binding of over 50% and, consequently, in incorrect positive values in the compound test. The Latex test is less suitable for diagnosis and course observation since it relatively often renders negative results at established cases of SLE with distinct illness activity on the one hand, while on the other hand, quantitative evidence, which is desirable for assessing the illness activity, is not possible. (orig./GSE) [de

  5. Monoclonal antibody against Porphyromonas (Bacteroides) endodontalis lipopolysaccharide and application of the antibody for direct identification of the species.

    OpenAIRE

    Hanazawa, S; Sagiya, T; Kitami, H; Ohta, K; Nishikawa, H; Kitano, S

    1991-01-01

    The aim of the present study was to develop a monoclonal antibody that recognizes the shared antigen of Porphyromonas endodontalis so that we could use the antibody in direct identification and detection of P. endodontalis in infectious material from apical periodontal patients. We established a hybridoma cell line producing monoclonal antibody (BEB5) specific for P. endodontalis. BEB5 antibody reacted with all of the P. endodontalis strains tested, but not with any of the other black-pigment...

  6. Detection of antibodies against H5 and H7 strains in birds: evaluation of influenza pseudovirus particle neutralization tests

    Directory of Open Access Journals (Sweden)

    Sofie Wallerström

    2014-01-01

    Full Text Available Introduction: Avian influenza viruses circulate in bird populations, and it is important to maintain and uphold our knowledge of the viral strains that are currently of interest in this context. Here, we describe the use of hemagglutinin-pseudotype retroviruses based on highly pathogenic influenza viruses for the screening of avian sera for influenza A antibodies. Our aim was also to determine whether the pseudovirus neutralization tests that we assessed were sensitive and simple to use compared to the traditional methods, including hemagglutination inhibition assays and microneutralization tests. Material and methods: H5 and H7 pseudovirus neutralization tests were evaluated by using serum from infected rabbits. Subsequently, the assays were further investigated using a panel of serum samples from avian species. The panel contained samples that were seropositive for five different hemagglutinin subtypes as well as influenza A seronegative samples. Results and discussion: The results suggest that the pseudovirus neutralization test is an alternative to hemagglutination inhibition assays, as we observed comparable titers to those of both standard microneutralizations assays as well as hemagglutinin inhibition assays. When evaluated by a panel of avian sera, the method also showed its capability to recognize antibodies directed toward low-pathogenic H5 and H7. Hence, we conclude that it is possible to use pseudoviruses based on highly pathogenic avian influenza viruses to screen avian sera for antibodies directed against influenza A subtypes H5 and H7.

  7. Rapid Transient Production of a Monoclonal Antibody Neutralizing the Porcine Epidemic Diarrhea Virus (PEDV) in Nicotiana benthamiana and Lactuca sativa.

    Science.gov (United States)

    Rattanapisit, Kaewta; Srijangwad, Anchalee; Chuanasa, Taksina; Sukrong, Suchada; Tantituvanont, Angkana; Mason, Hugh S; Nilubol, Dachrit; Phoolcharoen, Waranyoo

    2017-12-01

    Porcine epidemic diarrhea virus (PEDV) causes acute diarrhea, vomiting, dehydration, weight loss, and high mortality rate in neonatal piglets. Porcine epidemic diarrhea (PED) has been reported in Europe, America, and Asia including Thailand. The disease causes substantial losses to the swine industry in many countries. Presently, there is no effective PEDV vaccine available. In this study, we developed a plant-produced monoclonal antibody (mAb) 2C10 as a prophylactic candidate to prevent the PEDV infection. Recently, plant expression systems have gained interest as an alternative for the production of antibodies because of many advantages, such as low production cost, lack of human and animal pathogen, large scalability, etc. The 2C10 mAb was transiently expressed in Nicotiana benthamiana and lettuce using geminiviral vector. After purification by protein A affinity chromatography, the antibody was tested for the binding and neutralizing activity against PEDV. Our result showed that the plant produced 2C10 mAb can bind to the virus and also inhibit PEDV infection in vitro . These results show excellent potential for a plant-expressed 2C10 as a PEDV prophylaxis and a diagnostic for PEDV infection. Georg Thieme Verlag KG Stuttgart · New York.

  8. Hybridization-based antibody cDNA recovery for the production of recombinant antibodies identified by repertoire sequencing.

    Science.gov (United States)

    Valdés-Alemán, Javier; Téllez-Sosa, Juan; Ovilla-Muñoz, Marbella; Godoy-Lozano, Elizabeth; Velázquez-Ramírez, Daniel; Valdovinos-Torres, Humberto; Gómez-Barreto, Rosa E; Martinez-Barnetche, Jesús

    2014-01-01

    High-throughput sequencing of the antibody repertoire is enabling a thorough analysis of B cell diversity and clonal selection, which may improve the novel antibody discovery process. Theoretically, an adequate bioinformatic analysis could allow identification of candidate antigen-specific antibodies, requiring their recombinant production for experimental validation of their specificity. Gene synthesis is commonly used for the generation of recombinant antibodies identified in silico. Novel strategies that bypass gene synthesis could offer more accessible antibody identification and validation alternatives. We developed a hybridization-based recovery strategy that targets the complementarity-determining region 3 (CDRH3) for the enrichment of cDNA of candidate antigen-specific antibody sequences. Ten clonal groups of interest were identified through bioinformatic analysis of the heavy chain antibody repertoire of mice immunized with hen egg white lysozyme (HEL). cDNA from eight of the targeted clonal groups was recovered efficiently, leading to the generation of recombinant antibodies. One representative heavy chain sequence from each clonal group recovered was paired with previously reported anti-HEL light chains to generate full antibodies, later tested for HEL-binding capacity. The recovery process proposed represents a simple and scalable molecular strategy that could enhance antibody identification and specificity assessment, enabling a more cost-efficient generation of recombinant antibodies.

  9. Evaluation of Serum Specific Antibody against Recombinant ESAT-6 Antigen in Patients with Tuberculosis and Comparing to Normal Controls

    Directory of Open Access Journals (Sweden)

    Homeira Izadi

    2017-02-01

    Full Text Available Background & Objective: Tuberculosis (TB is a zoonotic disease which is caused by Mycobacterium tuberculosis. Because of common structural and secretory antigens between pathogen and nonpathogenic mycobacterium, the specific diagnosis of TB is difficult. Therefore, it is very important to find a new method with high specificity and sensitivity for accurate and rapid diagnosis of tuberculosis. In this study, the serodiagnostic potential of Mycobacterium tuberculosis recombinant ESAT-6 in TB infected patients was evaluated by Enzyme Linked Immunosorbent Assay (ELISA. Materials & Methods: 55 TB patients with active disease and 28 healthy controls have been collected and evaluated in different dilutions in ELISA methods for the presence of specific anti-ESAT-6 antibody. The specificity and the sensitivity of this method was compared with the culture test. Results: TB patients have high levels of specific antibody against ESAT-6 antigens. The specificity and the sensitivity of this method was calculated as 80.90% and 85.45%, respectively. Conclusion: These findings provide useful information on the importance of ESAT-6 protein and suggested this serologic test as a good alternative method for rapid and prefect diagnosis of tuberculosis.

  10. Micromethod for quantification of SH groups generated after reduction of monoclonal antibodies

    International Nuclear Information System (INIS)

    Escobar, Normando Iznaga; Morales, Alejo; Nunez, Gilda

    1996-01-01

    A simple, rapid, and reproducible micromethod for quantification of sulfhydryl (SH) groups generated after reduction of monoclonal antibody (MAb) disulfide bonds with 2-mercaptoethanol (2-ME) is described. The number of SH groups per molecule of antibody in the 2-ME and in the other reducing agents was calculated from the cysteine standard curve using Ellman's reagent to develop the yellow color. Results were plotted as absorbance at 405 nm vs. cysteine concentration (μg/mL). After subtraction of the background due to Ellman's reagent, a straight-line relationship passing through the origin was obtained. Absorption spectrum of the yellow products was controlled, and no significative differences were found between optical density at 412 nm and 405 nm. Using a small quantity of antibody in the order of 37 μg, the lowest detection limit for cysteine quantification was 0.03 μg. An excellent linear correlation was found between both cysteine concentration and absorbance (r = 0.999), and the mean value of the relative error in the quantification of cysteine from samples was 2.8%. A statistical Student t-test showed an excellent linearity and parallelism between cysteine standard and samples

  11. Micromethod for quantification of SH groups generated after reduction of monoclonal antibodies

    Energy Technology Data Exchange (ETDEWEB)

    Escobar, Normando Iznaga; Morales, Alejo; Nunez, Gilda

    1996-07-01

    A simple, rapid, and reproducible micromethod for quantification of sulfhydryl (SH) groups generated after reduction of monoclonal antibody (MAb) disulfide bonds with 2-mercaptoethanol (2-ME) is described. The number of SH groups per molecule of antibody in the 2-ME and in the other reducing agents was calculated from the cysteine standard curve using Ellman's reagent to develop the yellow color. Results were plotted as absorbance at 405 nm vs. cysteine concentration ({mu}g/mL). After subtraction of the background due to Ellman's reagent, a straight-line relationship passing through the origin was obtained. Absorption spectrum of the yellow products was controlled, and no significative differences were found between optical density at 412 nm and 405 nm. Using a small quantity of antibody in the order of 37 {mu}g, the lowest detection limit for cysteine quantification was 0.03 {mu}g. An excellent linear correlation was found between both cysteine concentration and absorbance (r = 0.999), and the mean value of the relative error in the quantification of cysteine from samples was 2.8%. A statistical Student t-test showed an excellent linearity and parallelism between cysteine standard and samples.

  12. Comparative evaluation of two rapid Salmonella-IgM tests and blood culture in the diagnosis of enteric fever.

    Science.gov (United States)

    Prasad, K J; Oberoi, J K; Goel, N; Wattal, C

    2015-01-01

    Enteric fever is a major public health problem in developing countries like India. An early and accurate diagnosis is necessary for a prompt and effective treatment. We have evaluated the diagnostic accuracy of two Rapid Salmonella-IgM tests (Typhidot-IgM and Enteroscreen-IgM) as compared to blood culture in rapid and early diagnosis of enteric fever. A total of 2,699 patients' serum samples were tested by Rapid Salmonella-IgM tests and blood culture. Patients were divided into two groups. Test group - patients with enteric fever and blood culture positives for Salmonella Typhi; and three types of Controls, i.e. patients with non-enteric fever illnesses, normal healthy controls and patients positive for S. Paratyphi- A. In addition to this we have also evaluated the significance of positive Salmonella-IgM tests among blood culture-negative cases. The overall sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of the Typhidot-IgM test and Enteroscreen-IgM test considering blood culture as gold standard were 97.29% and 88.13%, 97.40% and 87.83%, 98.18% and 92.03%, 96.15% and 82.27%, respectively. Typhidot-IgM test was found to be significantly more sensitive and specific as compared to Enteroscreen-IgM. Among blood culture-negative patients, Rapid Salmonella-IgM tests detected 72.25% additional cases of enteric fever. Although the Rapid Salmonella-IgM tests are meant to diagnose S. Typhi only, but these tests detect S. Paratyphi- A also. Thirty-eight patients who were blood culture-positive for S. Paratyphi- A were also positive by Rapid Salmonella-IgM tests. Rapid Salmonella-IgM tests offer an advantage of increased sensitivity, rapidity, early diagnosis and simplicity over blood culture.

  13. Comparison of in-house biotin-avidin tetanus IgG enzyme-linked-immunosorbent assay (ELISA) with gold standard in vivo mouse neutralization test for the detection of low level antibodies.

    Science.gov (United States)

    Sonmez, Cemile; Coplu, Nilay; Gozalan, Aysegul; Akin, Lutfu; Esen, Berrin

    2017-06-01

    Detection of anti-tetanus antibody levels is necessary for both determination of the immune status of individuals and also for planning preventive measures. ELISA is the preferred test among in vitro tests however it can be affected by the cross reacting antibodies. A previously developed in-house ELISA test was found not reliable for the antibody levels ≤1.0IU/ml. A new method was developed to detect low antibody levels correctly. The aim of the present study was to compare the results of the newly developed in-house biotin-avidin tetanus IgG ELISA test with the in vivo mouse neutralization test, for the antibody levels ≤1.0IU/ml. A total of 54 serum samples with the antibody levels of three different levels, =0.01IU/ml, 0.01-0.1IU/ml, 0.1-1IU/ml, which were detected by in vivo mouse neutralization test were studied by the newly developed in-house biotin-avidin tetanus IgG ELISA test. Test was validated by using five different concentrations (0.01IU/ml, 0.06IU/ml, 0.2IU/ml, 0.5IU/ml, 1.0IU/ml). A statistically significant correlation (r 2 =0.9967 p=0,001) between in vivo mouse neutralization test and in-house biotin-avidin tetanus IgG ELISA test, was observed. For the tested concentrations intra-assay, inter-assay, accuracy, sensitivity, specificity and coefficients of variations were determined as ≤15%. In-house biotin-avidin tetanus IgG ELISA test can be an alternative method to in vivo mouse neutralization method for the detection of levels ≤1.0IU/ml. By using in-house biotin-avidin tetanus IgG ELISA test, individuals with non protective levels, will be reliably detected. Copyright © 2017. Published by Elsevier B.V.

  14. Selection of phage-displayed accessible recombinant targeted antibodies (SPARTA): methodology and applications.

    Science.gov (United States)

    D'Angelo, Sara; Staquicini, Fernanda I; Ferrara, Fortunato; Staquicini, Daniela I; Sharma, Geetanjali; Tarleton, Christy A; Nguyen, Huynh; Naranjo, Leslie A; Sidman, Richard L; Arap, Wadih; Bradbury, Andrew Rm; Pasqualini, Renata

    2018-05-03

    We developed a potentially novel and robust antibody discovery methodology, termed selection of phage-displayed accessible recombinant targeted antibodies (SPARTA). This combines an in vitro screening step of a naive human antibody library against known tumor targets, with in vivo selections based on tumor-homing capabilities of a preenriched antibody pool. This unique approach overcomes several rate-limiting challenges to generate human antibodies amenable to rapid translation into medical applications. As a proof of concept, we evaluated SPARTA on 2 well-established tumor cell surface targets, EphA5 and GRP78. We evaluated antibodies that showed tumor-targeting selectivity as a representative panel of antibody-drug conjugates (ADCs) and were highly efficacious. Our results validate a discovery platform to identify and validate monoclonal antibodies with favorable tumor-targeting attributes. This approach may also extend to other diseases with known cell surface targets and affected tissues easily isolated for in vivo selection.

  15. Immunochromatographic Lateral-flow test strip for the rapid detection of added bovine rennet whey in milk and milk powder

    NARCIS (Netherlands)

    Martin-Hernandez, C.; Munoz, M.; Daury, C.; Weymuth, H.; Kemmers-Voncken, A.; Corbation, V.; Toribo, T.; Bremer, M.G.E.G.

    2009-01-01

    An immunochromatographic lateral-flow test dipstick test was developed for the fast detection of bovine rennet whey in liquid milk and milk powder. The test is based on the binding of casein glycomacropeptide (cGMP) by two specific anti-bovine ¿-casein monoclonal antibodies and has a visual

  16. Rapid detection, characterization, and enumeration of foodborne pathogens.

    Science.gov (United States)

    Hoorfar, J

    2011-11-01

    As food safety management further develops, microbiological testing will continue to play an important role in assessing whether Food Safety Objectives are achieved. However, traditional microbiological culture-based methods are limited, particularly in their ability to provide timely data. The present review discusses the reasons for the increasing interest in rapid methods, current developments in the field, the research needs, and the future trends. The advent of biotechnology has introduced new technologies that led to the emergence of rapid diagnostic methods and altered food testing practices. Rapid methods are comprised of many different detection technologies, including specialized enzyme substrates, antibodies and DNA, ranging from simple differential plating media to the use of sophisticated instruments. The use of non-invasive sampling techniques for live animals especially came into focus with the 1990s outbreak of bovine spongiform encephalopathy that was linked to the human outbreak of Creutzfeldt Jakob's Disease. Serology is still an important tool in preventing foodborne pathogens to enter the human food supply through meat and milk from animals. One of the primary uses of rapid methods is for fast screening of large number of samples, where most of them are expected to be test-negative, leading to faster product release for sale. This has been the main strength of rapid methods such as real-time Polymerase Chain Reaction (PCR). Enrichment PCR, where a primary culture broth is tested in PCR, is the most common approach in rapid testing. Recent reports show that it is possible both to enrich a sample and enumerate by pathogen-specific real-time PCR, if the enrichment time is short. This can be especially useful in situations where food producers ask for the level of pathogen in a contaminated product. Another key issue is automation, where the key drivers are miniaturization and multiple testing, which mean that not only one instrument is flexible

  17. Severe antiphospholipid antibody syndrome - response to plasmapheresis and rituximab.

    Science.gov (United States)

    Gkogkolou, Paraskevi; Ehrchen, Jan; Goerge, Tobias

    2017-09-01

    Antiphospholipid antibody syndrome (APS) is a systemic autoimmune disease characterized by arterial and/or venous thrombosis, recurrent abortions and detection of antiphospholipid antibodies. In fulminant cases, involvement of multiple organs can lead to significant morbidity and even fatal outcomes, so that a rapid, interdisciplinary treatment is needed. Here, we describe the case of a 39-year-old woman with a severe hard-to-treat APS with arterial occlusion and progressive skin necrosis, who was successfully treated with a combination therapy with plasmapheresis and rituximab. The treatment led to complete remission of the skin lesions for over a year. Clinical response correlated with a long-lasting reduction of antiphospholipid antibodies and B-cell depletion. This case demonstrates the use of antiphospholipid antibodies for monitoring APS-activity and shows that this severe vascular disease requires rigorous therapeutic approaches.

  18. Comparative assay of fluorescent antibody test results among twelve European National Reference Laboratories using various anti-rabies conjugates

    DEFF Research Database (Denmark)

    Robardet, E.; Andrieu, S.; Rasmussen, Thomas Bruun

    2013-01-01

    Twelve National Reference Laboratories (NRLs) for rabies have undertaken a comparative assay to assess the comparison of fluorescent antibody test (FAT) results using five coded commercial anti-rabies conjugates (Biorad, Bioveta, Fujirebio, Millipore, and SIFIN conjugates). Homogenized positive...

  19. Anti-transferrin receptor antibody and antibody-drug conjugates cross the blood-brain barrier

    International Nuclear Information System (INIS)

    Friden, P.M.; Walus, L.R.; Musso, G.F.; Taylor, M.A.; Malfroy, B.; Starzyk, R.M.

    1991-01-01

    Delivery of nonlipophilic drugs to the brain is hindered by the tightly apposed capillary endothelial cells that make up the blood-brain barrier. The authors have examined the ability of a monoclonal antibody (OX-26), which recognizes the rat transferrin receptor, to function as a carrier for the delivery of drugs across the blood-brain barrier. This antibody, which was previously shown to bind preferentially to capillary endothelial cells in the brain after intravenous administration, labels the entire cerebrovascular bed in a dose-dependent manner. The initially uniform labeling of brain capillaries becomes extremely punctate ∼ 4 hr after injection, suggesting a time-dependent sequestering of the antibody. Capillary-depletion experiments, in which the brain is separated into capillary and parenchymal fractions, show a time-dependent migration of radiolabeled antibody from the capillaries into the brain parenchyma, which is consistent with the transcytosis of compounds across the blood-brain barrier. Antibody-methotrexate conjugates were tested in vivo to assess the carrier ability of this antibody. Immunohistochemical staining for either component of an OX-26-methotrexate conjugate revealed patterns of cerebrovascular labeling identical to those observed with the unaltered antibody. Accumulation of radiolabeled methotrexate in the brain parenchyma is greatly enhanced when the drug is conjugated to OX-26

  20. Estimation of sensitivity, specificity and predictive values of two serologic tests for the detection of antibodies against Actinobacillus pleuropneumoniae serotype 2 in the absence of a reference test (gold standard)

    DEFF Research Database (Denmark)

    Enøe, Claes; Andersen, Søren; Sørensen, Vibeke

    2001-01-01

    Latent-class models were used to determine the sensitivity, specificity and predictive values of a polyclonal blocking enzyme-linked immunosorbent assay (ELISA) and a modified complement-fixation test (CFT) when there was no reference test. The tests were used for detection of antibodies against ...

  1. Imaging of myocardial infarction in dogs and humans using monoclonal antibodies specific for human myosin heavy chains

    International Nuclear Information System (INIS)

    Leger, J.; Chevalier, J.; Larue, C.; Gautier, P.; Planchenault, J.; Aumaitre, E.; Messner, P.; Puech, P.; Saccavini, J.C.; Pau, B.

    1991-01-01

    The use of three different monoclonal antibodies specific for human ventricular myosin heavy chains in the visualization of the location and extent of necrosis in dogs with experimental acute myocardial infarction and in humans is described. Using a classic immunohistochemical method or ex vivo analysis of heart slices in dogs with acute myocardial infarction subjected to intravenous injection of unlabeled antimyosin antibodies or antimyosin antibodies labeled with indium-111, it was observed that all antibody fragments specifically reached the targeted necrotic zone less than 2 h after antibody injection and remained bound for up to 24 h. In a limited but significant number of cases (5 of the 12 humans and 11 of 43 dogs), it was possible to image the necrotic zone in vivo as early as 2 to 4 h after antibody injection. In other cases, individual blood clearance variations retarded or even prevented in vivo necrosis detection. Higher antimyosin fixation values were obtained in the necrotic zones in dogs with a rapid blood clearance relative to that of the other dogs. It is concluded that antimyosin antibodies always reached necrotic areas within 2 h. If blood clearance was rapid, in vivo imaging of the necrotic area was possible 2 to 6 h after necrosis, even in humans. In some cases, however, uncontrolled individual variations in the timing required for sufficient blood clearance hampered this rapid in vivo detection of myocardial necrosis

  2. Addressing unmet need for HIV testing in emergency care settings: a role for computer-facilitated rapid HIV testing?

    Science.gov (United States)

    Kurth, Ann E; Severynen, Anneleen; Spielberg, Freya

    2013-08-01

    HIV testing in emergency departments (EDs) remains underutilized. The authors evaluated a computer tool to facilitate rapid HIV testing in an urban ED. Randomly assigned nonacute adult ED patients were randomly assigned to a computer tool (CARE) and rapid HIV testing before a standard visit (n = 258) or to a standard visit (n = 259) with chart access. The authors assessed intervention acceptability and compared noted HIV risks. Participants were 56% nonWhite and 58% male; median age was 37 years. In the CARE arm, nearly all (251/258) of the patients completed the session and received HIV results; four declined to consent to the test. HIV risks were reported by 54% of users; one participant was confirmed HIV-positive, and two were confirmed false-positive (seroprevalence 0.4%, 95% CI [0.01, 2.2]). Half (55%) of the patients preferred computerized rather than face-to-face counseling for future HIV testing. In the standard arm, one HIV test and two referrals for testing occurred. Computer-facilitated HIV testing appears acceptable to ED patients. Future research should assess cost-effectiveness compared with staff-delivered approaches.

  3. Clinical experience in humans with radiolabeled antibody for tumor detection

    International Nuclear Information System (INIS)

    Morrison, R.T.; Lyster, D.M.; Szasz, I.; Alcorn, L.N.; Huckell, V.F.; Rhodes, B.; Breslow, K.; Burchiel, S.

    1982-01-01

    I-131 and Tc-99m labeled polyclonal or monoclonal antibody and fragments of antibody, specific to human chorionic gonadotropin (hCG) or to a melanoma cell surface antigen (MCSA) were injected into proven cancer patients. Using standard homeostasis parameters, and scanning techniques, the safety and efficacy of each antibody was evaluated. Antibody fragments were expected to clear faster from the circulation allowing for earlier imaging and a better target-to-non-target ratio. The technetium label may perturb the antiboby's kinetics so that clearance is more rapid for both whole antibody and fragments. After a statistical evaluation of all parameters measured pre and post injection it was concluded that no acute toxicity reactions were present in any patient studied. Scan results were not acceptable for a tumor detecting procedure used in routine practice. Tumor upake was seen in less than 10% of scans

  4. Immunization of chickens with an agonistic monoclonal anti-chicken CD40 antibody-hapten complex: rapid and robust IgG response induced by a single subcutaneous injection.

    Science.gov (United States)

    Chen, Chang-Hsin; Abi-Ghanem, Daad; Waghela, Suryakant D; Chou, Wen-Ko; Farnell, Morgan B; Mwangi, Waithaka; Berghman, Luc R

    2012-04-30

    Producing diagnostic antibodies in chicken egg yolk represents an alternate animal system that offers many advantages including high productivity at low cost. Despite being an excellent counterpart to mammalian antibodies, chicken IgG from yolk still represents an underused resource. The potential of agonistic monoclonal anti-CD40 antibodies (mAb) as a powerful immunological adjuvant has been demonstrated in mammals, but not in chickens. We recently reported an agonistic anti-chicken CD40 mAb (designated mAb 2C5) and showed that it may have potential as an immunological adjuvant. In this study, we examined the efficacy of targeting a short peptide to chicken CD40 [expressed by the antigen-presenting cells (APCs)] in enhancing an effective IgG response in chickens. For this purpose, an immune complex consisting of one streptavidin molecule, two directionally biotinylated mAb 2C5 molecules, and two biotinylated peptide molecules was produced. Chickens were immunized subcutaneously with doses of this complex ranging from 10 to 90 μg per injection once, and relative quantification of the peptide-specific IgG response showed that the mAb 2C5-based complex was able to elicit a strong IgG response as early as four days post-immunization. This demonstrates that CD40-targeting antigen to chicken APCs can significantly enhance antibody responses and induce immunoglobulin isotype-switching. This immunization strategy holds promise for rapid production of hapten-specific IgG in chickens. Copyright © 2012 Elsevier B.V. All rights reserved.

  5. Prevalence of Antibodies Against Hepatitis e Virus in Veterinarians in Estonia

    DEFF Research Database (Denmark)

    Lassen, Brian; Janson, Marilin; Neare, Kädi

    2017-01-01

    positive with both tests. Antibody-positive samples were further examined for the presence of HEV RNA. Three (2.6%) of the 115 veterinarians tested positive for immunoglobulin G antibodies against HEV, whereas no immunoglobulin M antibodies against the virus were detected. The antibody......-positive veterinarians were small animal practitioners. Pigs comprised no or small part of their working time or patients. No HEV RNA was detected in the antibody-positive samples. The prevalence of antibodies against HEV in veterinarians in Estonia was lower than what has been observed in veterinarians in other...

  6. Two rapid pigmentation tests for identification of Cryptococcus neoformans.

    Science.gov (United States)

    Kaufmann, C S; Merz, W G

    1982-01-01

    Two tests were developed for the rapid identification of Cryptococcus neoformans based on pigment produced by the organism's phenoloxidase activity. Caffeic acid was incorporated into cornmeal agar, a medium used routinely for yeast identification. When tested on this medium, only C. neoformans isolates produced brown pigment. All other yeasts maintained their normal morphology and did not produce the reaction product. A non-medium-based test was developed for same-day identification of C. neoformans isolates. Paper strips saturated with a buffered L-beta-3,4-dihydroxyphenylalanine-ferric citrate solution were inoculated with isolates and incubated at 37 degrees C. Pigment production occurred only with C. neoformans isolates, many within 60 to 90 min. All other yeasts remained negative. PMID:7040452

  7. Microradioimmunoassay for antibodies to tumor-associated antigens

    International Nuclear Information System (INIS)

    Huang, J.C.C.; Berczi, I.; Froese, G.; Tsay, H.M.; Sehon, A.H.

    1975-01-01

    A versatile microradioimmunoassay for the detection of antibodies to tumor-associated and other tissue antigens was described. The method involved: the preparation of solid-phase antigen with cultured (already adhered) or noncultured cells (sedimented by centrifugation) fixed to Micro-Test plates with neutral buffered formaldehyde or absolute methanol; the incubation of the antigen with test or control sera; and the incubation of the antigen with radioiodinated antiglobulin antibody. The nonspecific background of radioactivity was reduced to an acceptable level by the fixed cells being precoated in the wells with 0.5 percent bovine serum albumin in phosphate-buffered saline which was also used for the dilution of sera and labeled antiglobulin antibody. Tumor cells in primary cultures gave a high background, as compared to long-term cultures, which was due to the presence of immunoglobulins (most likely tumor-specific antibody). The specific antibody response to a syngeneic mouse tumor was demonstrated by this technique. (auth)

  8. Mouse-specific antibody responses to a monoclonal antibody during repeated immunoscintigraphy investigations: Comparison of antibody titres and imaging studies in a rat model

    International Nuclear Information System (INIS)

    Pimm, M.V.; Gribben, S.J.; Markham, A.J.; Perkins, A.C.

    1990-01-01

    As a model for human mouse-specific antibody responses in patients undergoing immunoscintigraphy, we have investigated in rats the production of mouse-specific antibodies (MA) to the mouse monoclonal antibody 791T/36. At intervals of between 5 and 16 weeks the rats were given repeated cycles of intravenous (IV) injections of antibody with or without a simultaneous intradermal (ID) injection. The IV dose was 60 μg/kg, a dose similar to that used in many clinical immunoscintigraphy studies. The ID injection was 2 μg, which mimicks the skin test dose often given in clinical imaging protocols. The study was carried out with both 131 I-labelled antibody and with antibody labelled with 111 In by DTPA chelation. MA was measured with a passive haemagglutination assay using sheep red blood cells coated with the monoclonal antibody. Of rats given ID injections of unlabelled antibody at the same time as the IV imaging doses, 9/20 produced MA during 4 cycles of injections. In contrast, only 2/16 rats given only the IV dose produced MA. Both 131 I- and 111 In-labelled antibody appeared equally immunogenic with 5/18 and 6/18 overall responders, respectively. The production of MA was associated with a significant perturbation in the biodistribution of the IV dose of labelled antibody as seen by gamma-camera imaging of the rats given 111 In-labelled antibody. There was clearance of immune complexes to the liver, this organ accumulating up to 90% of the whole body count rate of radiolabel. MA titres of between 1/100 and 1/78000 caused equal perturbation of biodistribution, although below 1/100 the effect was more variable. (orig.)

  9. Antibodies against rabies virus in dogs with and without history of vaccination in Santa Maria - RS - Brazil

    Directory of Open Access Journals (Sweden)

    Karina Gonzalez Fernandes

    2017-10-01

    Full Text Available ABSTRACT: The present study investigated the frequency and magnitude of neutralizing antibodies to rabies virus (RABV in dogs with and without historic of vaccination in Santa Maria/RS. Group A included serum samples from 440 dogs with recent historic of vaccination against rabies, obtained during the 2015 rabies vaccination campaign. Group B included 300 serum samples from dogs submitted to the Veterinary Hospital of the Universidade Federal de Santa Maria in 2015, whose historic of rabies vaccination was unknown. Serum samples were submitted to the rapid fluorescent focus inhibition test (RFFIT to detect neutralizing antibodies against RABV. In group A, 70.6% (310/440 of the samples had neutralizing antibody titers ≥0.5 international units per milliliter (IU mL-1, considered an indicative of protection against rabies by the World Health Organization. However, approximately 30% of the dogs did not contain antibodies in adequate levels. In group B, 42.3% (127/300 of the samples contained neutralizing antibody titers ≥0.5IU mL-1 and 57.7% (173/300 were negative or contained titers below of the value considered immunized. These results demonstrate that an important proportion of vaccinated dogs (~30% did not develop adequate antibody levels, mainly those receiving a single vaccine dose. Serologic testing of animals with unknown historic of vaccination revealed relatively low vaccine coverage in the general dog population. Thus, reformulation of immunization strategies - especially the recommendation of a boost vaccination 30 days after the primary dose - and extension of vaccination campaigns are necessary to reach adequate levels and coverage of immunity against RABV in the canine population.

  10. A monoclonal antibody to inclusion body disease of cranes virus enabling specific immunohistochemistry and competitive ELISA

    Science.gov (United States)

    Letchworth, G.J.; Fishel, J.R.; Hansen, W.R.

    1997-01-01

    Inclusion body disease of cranes (IBDC) herpesvirus kills some infected cranes and persists in convalescent animals. To enable further study and rapid identification of carrier animals, we developed a monoclonal antibody (MAb) to IBDC virus and used it in immunohistochemistry and a competitive enzyme-linked immunosorbent assay (ELISA). We used conventional techniques to make murine MAbs directed against IBDC virus purified from infected duck embryo cells. Hybridomas reacting in an ELISA with IBDC virus but not uninfected duck embryo cells were characterized by radioimmunoprecipitation, in situ immunohistochemistry, and competitive ELISA with neutralizing and nonneutralizing crane sera. MAb 2C11 immunoprecipitated 59-, 61-, and 110-kD proteins from IBDC virus-infected but not uninfected cells and stained glutaraldehyde-fixed IBDC virus plaques but not surrounding uninfected duck embryo cells in vitro. Antibody 2C11 did not react with duck embryo cells infected with falcon herpesvirus, psittacine herpesvirus, infectious laryngotracheitis, pigeon herpesvirus, or duck plague virus. A competitive ELISA using antibody 2C11 identified most sera that were positive in the neutralization test. This antibody will be useful in further characterizing IBDC virus, its pathogenesis, and its natural history.

  11. Generation of human antibody fragments recognizing distinct epitopes of the nucleocapsid (N SARS-CoV protein using a phage display approach

    Directory of Open Access Journals (Sweden)

    Grasso Felicia

    2005-09-01

    Full Text Available Abstract Background Severe acute respiratory syndrome (SARS-CoV is a newly emerging virus that causes SARS with high mortality rate in infected people. Successful control of the global SARS epidemic will require rapid and sensitive diagnostic tests to monitor its spread, as well as, the development of vaccines and new antiviral compounds including neutralizing antibodies that effectively prevent or treat this disease. Methods The human synthetic single-chain fragment variable (scFv ETH-2 phage antibody library was used for the isolation of scFvs against the nucleocapsid (N protein of SARS-CoV using a bio panning-based strategy. The selected scFvs were characterized under genetics-molecular aspects and for SARS-CoV N protein detection in ELISA, western blotting and immunocytochemistry. Results Human scFv antibodies to N protein of SARS-CoV can be easily isolated by selecting the ETH-2 phage library on immunotubes coated with antigen. These in vitro selected human scFvs specifically recognize in ELISA and western blotting studies distinct epitopes in N protein domains and detect in immunohistochemistry investigations SARS-CoV particles in infected Vero cells. Conclusion The human scFv antibodies isolated and described in this study represent useful reagents for rapid detection of N SARS-CoV protein and SARS virus particles in infected target cells.

  12. A point-of-care test for measles diagnosis: detection of measles-specific IgM antibodies and viral nucleic acid.

    Science.gov (United States)

    Warrener, Lenesha; Slibinskas, Rimantas; Chua, Kaw Bing; Nigatu, Wondatir; Brown, Kevin E; Sasnauskas, Kestutis; Samuel, Dhanraj; Brown, David

    2011-09-01

    To evaluate the performance of a newly developed point-of-care test (POCT) for the detection of measles-specific IgM antibodies in serum and oral fluid specimens and to assess if measles virus nucleic acid could be recovered from used POCT strips. The POCT was used to test 170 serum specimens collected through measles surveillance or vaccination programmes in Ethiopia, Malaysia and the Russian Federation: 69 were positive for measles immunoglobulin M (IgM) antibodies, 74 were positive for rubella IgM antibodies and 7 were positive for both. Also tested were 282 oral fluid specimens from the measles, mumps and rubella (MMR) surveillance programme of the United Kingdom of Great Britain and Northern Ireland. The Microimmune measles IgM capture enzyme immunoassay was the gold standard for comparison. A panel of 24 oral fluids was used to investigate if measles virus haemagglutinin (H) and nucleocapsid (N) genes could be amplified by polymerase chain reaction directly from used POCT strips. With serum POCT showed a sensitivity and specificity of 90.8% (69/76) and 93.6% (88/94), respectively; with oral fluids, sensitivity and specificity were 90.0% (63/70) and 96.2% (200/208), respectively. Both H and N genes were reliably detected in POCT strips and the N genes could be sequenced for genotyping. Measles virus genes could be recovered from POCT strips after storage for 5 weeks at 20-25 °C. The POCT has the sensitivity and specificity required of a field-based test for measles diagnosis. However, its role in global measles control programmes requires further evaluation.

  13. A simple sandwich ELISA (WELYSSA) for the detection of lyssavirus nucleocapsid in rabies suspected specimens using mouse monoclonal antibodies.

    Science.gov (United States)

    Xu, Gelin; Weber, Patrick; Hu, Qiaoling; Xue, Honggang; Audry, Laurent; Li, Chengping; Wu, Jie; Bourhy, Herve

    2007-10-01

    Monoclonal antibody (MAb)-based capture enzyme-linked immunosorbent assays (ELISA) were developed for the diagnosis of rabies-suspect specimens. A combination of four mouse monoclonal antibodies directed against the rabies virus nucleocapsid was selected and used for the detection. The test was optimized and standardized so that maximum concordance could be maintained with the standard procedures of rabies diagnosis recommended by the WHO expert committee. Using prototype viruses from the different genotypes of lyssavirus and from various geographic origins and phylogenetic lineages, this paper presents a reliable, rapid and transferable diagnostic method, named WELYSSA that readily permits the detection of lyssaviruses belonging to the 7 genotypes of lyssavirus circulating in Europe, Africa, Asia and Oceania. The threshold of detection of lyssavirus nucleocapsids is low (0.8 ng/ml). With a panel of 1030 specimens received for rabies diagnostic testing, this test was found to be highly specific (0.999) and sensitive (0.970) when compared to other recommended rabies diagnostic methods.

  14. DETECTION OF RABIES VIRAL ANTIGEN IN CATTLE BY RAPID IMMUNOCHROMTOGRAPHIC DIAGNOSTIC TEST

    Directory of Open Access Journals (Sweden)

    Santanu Panda

    2016-06-01

    Full Text Available In recent years, improved quality, accuracy and speed for diagnosis of rabies has been adopted for rabies control strategies in developing countries. In field condition, rapid immunochromtographic diagnostic test (RIDT is a true requirement for rapid epidemiological surveillance of rabies. In the present study, a total of ten numbers of rabies suspected cattle brain sample form different parts of West Bengal, India were examined through RIDT. The results revealed that one sample was found to be positive. The test was established as powerful screening tool for rabies with high sensitivity and specificity. Thus, RIDT can be employed as a reliable and quick approach for diagnosis and control of rabies under field condition.

  15. Application of the indirect enzyme-labeled antibody microtest to the detection and surveillance of animal diseases. [Brucellosis, cholera, and trichinosis in cattle and swine

    Energy Technology Data Exchange (ETDEWEB)

    Saunders, G.C. Clinard, E.H.; Bartlett, M.L.; Sanders, W.M.

    1976-01-01

    The rapid, indirect enzyme-labeled antibody (ELA) microplate test has been developed as a diagnostic and surveillance tool to aid in the control of animal disease. Data are presented, which illustrate the application of the test to viral (hog cholera), parasitic (trichinosis), and bacterial (brucellosis) diseases of animals. A greater than 95 percent correlation was observed between the hog cholera ELA test and the hog cholera serum neutralization test performed on over 2000 mixed hog cholera positive and negative field samples obtained during the 1976 New Jersey epizootic. Of 56 swine naturally infected with Trichinella spiralis at a level considered dangerous to man, all were ELA positive, while only one of 360 T. spiralis negative packing house sera was ELA positive. Preliminary experiments with bovine brucellosis (Brucella abortus) indicate that the ELA test is more sensitive than other test methods currently in use. ELA procedures should soon become tests of choice for the detection of antibodies to animal disease agents.

  16. Continuous-Flow Detector for Rapid Pathogen Identification

    Energy Technology Data Exchange (ETDEWEB)

    Barrett, Louise M. [Sandia National Lab. (SNL-CA), Livermore, CA (United States). Microfluidics; Skulan, Andrew J. [Sandia National Lab. (SNL-CA), Livermore, CA (United States). Microfluidics; Singh, Anup K. [Sandia National Lab. (SNL-CA), Livermore, CA (United States). Microfluidics; Cummings, Eric B. [Sandia National Lab. (SNL-CA), Livermore, CA (United States). Microfluidics; Fiechtner, Gregory J. [Sandia National Lab. (SNL-CA), Livermore, CA (United States). Microfluidics

    2006-09-01

    This report describes the continued development of a low-power, portable detector for the rapid identification of pathogens such as B. anthracis and smallpox. Based on our successful demonstration of the continuous filter/concentrator inlet, we believe strongly that the inlet section will enable differentiation between viable and non-viable populations, between types of cells, and between pathogens and background contamination. Selective, continuous focusing of particles in a microstream enables highly selective and sensitive identification using fluorescently labeled antibodies and other receptors such as peptides, aptamers, or small ligands to minimize false positives. Processes such as mixing and lysing will also benefit from the highly localized particle streams. The concentrator is based on faceted prisms to contract microfluidic flows while maintaining uniform flowfields. The resulting interfaces, capable of high throughput, serve as high-, low-, and band-pass filters to direct selected bioparticles to a rapid, affinity-based detection system. The proposed device is superior to existing array-based detectors as antibody-pathogen binding can be accomplished in seconds rather than tens of minutes or even hours. The system is being designed to interface with aerosol collectors under development by the National Laboratories or commercial systems. The focused stream is designed to be interrogated using diode lasers to differentiate pathogens by light scattering. Identification of particles is done using fluorescently labeled antibodies to tag the particles, followed by multiplexed laser-induced fluorescence (LIF) detection (achieved by labeling each antibody with a different dye).

  17. 5-HIAA Test

    Science.gov (United States)

    ... PF4 Antibody Hepatitis A Testing Hepatitis B Testing Hepatitis C Testing HER2/neu Herpes Testing High-sensitivity C-reactive Protein (hs-CRP) Histamine Histone Antibody HIV Antibody and HIV Antigen (p24) HIV Antiretroviral Drug Resistance Testing, Genotypic HIV Viral Load HLA Testing HLA- ...

  18. Uric Acid Test

    Science.gov (United States)

    ... PF4 Antibody Hepatitis A Testing Hepatitis B Testing Hepatitis C Testing HER2/neu Herpes Testing High-sensitivity C-reactive Protein (hs-CRP) Histamine Histone Antibody HIV Antibody and HIV Antigen (p24) HIV Antiretroviral Drug Resistance Testing, Genotypic HIV Viral Load HLA Testing HLA- ...

  19. Direct Antiglobulin Test

    Science.gov (United States)

    ... PF4 Antibody Hepatitis A Testing Hepatitis B Testing Hepatitis C Testing HER2/neu Herpes Testing High-sensitivity C-reactive Protein (hs-CRP) Histamine Histone Antibody HIV Antibody and HIV Antigen (p24) HIV Antiretroviral Drug Resistance Testing, Genotypic HIV Viral Load HLA Testing HLA- ...

  20. CK-MB Test

    Science.gov (United States)

    ... PF4 Antibody Hepatitis A Testing Hepatitis B Testing Hepatitis C Testing HER2/neu Herpes Testing High-sensitivity C-reactive Protein (hs-CRP) Histamine Histone Antibody HIV Antibody and HIV Antigen (p24) HIV Antiretroviral Drug Resistance Testing, Genotypic HIV Viral Load HLA Testing HLA- ...

  1. Understanding Your Tests

    Science.gov (United States)

    ... PF4 Antibody Hepatitis A Testing Hepatitis B Testing Hepatitis C Testing HER2/neu Herpes Testing High-sensitivity C-reactive Protein (hs-CRP) Histamine Histone Antibody HIV Antibody and HIV Antigen (p24) HIV Antiretroviral Drug Resistance Testing, Genotypic HIV Viral Load HLA Testing HLA- ...

  2. Myasthenia Gravis Tests

    Science.gov (United States)

    ... PF4 Antibody Hepatitis A Testing Hepatitis B Testing Hepatitis C Testing HER2/neu Herpes Testing High-sensitivity C-reactive Protein (hs-CRP) Histamine Histone Antibody HIV Antibody and HIV Antigen (p24) HIV Antiretroviral Drug Resistance Testing, Genotypic HIV Viral Load HLA Testing HLA- ...

  3. Factors associated with willingness to accept oral fluid HIV rapid testing among most-at-risk populations in China.

    Directory of Open Access Journals (Sweden)

    Huanmiao Xun

    Full Text Available The availability of oral fluid HIV rapid testing provides an approach that may have the potential to expand HIV testing in China, especially among most-a-risk populations. There are few investigations about the acceptability of oral fluid HIV testing among most-at-risk populations in China.A cross-sectional study with men who have sex with men (MSM, female sex workers (FSW and voluntary counseling and testing (VCT clients was conducted in three cities of Shandong province, China from 2011 to 2012. Data were collected by face-to-face questionnaire.About 71% of participants were willing to accept the oral fluid HIV rapid testing, and home HIV testing was independently associated with acceptability of the new testing method among MSM, FSW and VCT clients (AOR of 4.46, 3.19 and 5.74, respectively. Independent predictors of oral fluid HIV rapid testing acceptability among MSM were having ever taken an oral fluid HIV rapid test (AOR= 15.25, having ever taken an HIV test (AOR= 2.07, and education level (AOR= 1.74. Engagement in HIV-related risk behaviors (AOR= 1.68 was an independent predictor of acceptability for FSW. Having taken an HIV test (AOR= 2.85 was an independent predictor of acceptability for VCT clients. The primary concern about the oral fluid HIV testing was accuracy. The median price they would pay for the testing ranged from 4.8 to 8.1 U.S. dollars.High acceptability of oral fluid HIV rapid testing was shown among most-at-risk populations. Findings provide support for oral rapid HIV testing as another HIV prevention tool, and provide a backdrop for the implementation of HIV home testing in the near future. Appropriate pricing and increased public education through awareness campaigns that address concerns about the accuracy and safety of the oral fluid HIV rapid testing may help increase acceptability and use among most-at-risk populations in China.

  4. Dipstick test for rapid diagnosis of Shigella dysenteriae 1 in bacterial cultures and its potential use on stool samples.

    Directory of Open Access Journals (Sweden)

    Neelam Taneja

    Full Text Available BACKGROUND: We describe a test for rapid detection of S. dysenteriae 1 in bacterial cultures and in stools, at the bedside of patients. METHODOLOGY/PRINCIPAL FINDINGS: The test is based on the detection of S. dysenteriae 1 lipopolysaccharide (LPS using serotype 1-specific monoclonal antibodies coupled to gold particles and displayed on a one-step immunochromatographic dipstick. A concentration as low as 15 ng/ml of LPS was detected in distilled water and in reconstituted stools in 10 minutes. In distilled water and in reconstituted stools, an unequivocal positive reaction was obtained with 1.6×10⁶ CFU/ml and 4.9×10⁶ CFU/ml of S. dysenteriae 1, respectively. Optimal conditions to read the test have been determined to limit the risk of ambiguous results due to appearance of a faint yellow test band in some negative samples. The specificity was 100% when tested with a battery of Shigella and unrelated strains in culture. When tested on 328 clinical samples in India, Vietnam, Senegal and France by laboratory technicians and in Democratic Republic of Congo by a field technician, the specificity (312/316 was 98.7% (95% CI:96.6-99.6% and the sensitivity (11/12 was 91.7% (95% CI:59.8-99.6%. Stool cultures and the immunochromatographic test showed concordant results in 98.4 % of cases (323/328 in comparative studies. Positive and negative predictive values were 73.3% (95% CI:44.8-91.1% and 99.7% (95% CI:98-100%. CONCLUSION: The initial findings presented here for a simple dipstick-based test to diagnose S. dysenteriae 1 demonstrates its promising potential to become a powerful tool for case management and epidemiological surveys.

  5. Comparison of Two Assays to Determine Anti-Citrullinated Peptide Antibodies in Rheumatoid Arthritis in relation to Other Chronic Inflammatory Rheumatic Diseases: Assaying Anti-Modified Citrullinated Vimentin Antibodies Adds Value to Second-Generation Anti-Citrullinated Cyclic Peptides Testing

    Directory of Open Access Journals (Sweden)

    Miriam Lizette Díaz-Toscano

    2014-01-01

    Full Text Available Determination of anti-citrullinated peptide antibodies (ACPA plays a relevant role in the diagnosis of rheumatoid arthritis (RA. To date, it is still unclear if the use of several tests for these autoantibodies in the same patient offers additional value as compared to performing only one test. Therefore, we evaluated the performance of using two assays for ACPA: second-generation anti-citrullinated cyclic peptides antibodies (anti-CCP2 and anti-mutated citrullinated vimentin (anti-MCV antibodies for the diagnosis of RA. We compared three groups: RA (n=142, chronic inflammatory disease (CIRD, n=86, and clinically healthy subjects (CHS, n=56 to evaluate sensitivity, specificity, predictive values, and likelihood ratios (LR of these two assays for the presence of RA. A lower frequency of positivity for anti-CCP2 was found in RA (66.2% as compared with anti-MCV (81.0%. When comparing RA versus other CIRD, sensitivity increased when both assays were performed. This strategy of testing both assays had high specificity and LR+. We conclude that adding the assay of anti-MCV antibodies to the determination of anti-CCP2 increases the sensitivity for detecting seropositive RA. Therefore, we propose the use of both assays in the initial screening of RA in longitudinal studies, including early onset of undifferentiated arthritis.

  6. Antithyroglobulin antibody

    Science.gov (United States)

    Thyroglobulin antibody; Thyroiditis - thyroglobulin antibody; Hypothyroidism - thyroglobulin antibody; Thyroiditis - thyroglobulin antibody; Graves disease - thyroglobulin antibody; Underactive thyroid - thyroglobulin antibody

  7. Complement-fixing antibodies against denatured HLA and MICA antigens are associated with antibody mediated rejection.

    Science.gov (United States)

    Cai, Junchao; Terasaki, Paul I; Zhu, Dong; Lachmann, Nils; Schönemann, Constanze; Everly, Matthew J; Qing, Xin

    2016-02-01

    We have found antibodies against denatured HLA class I antigens in the serum of allograft recipients which were not significantly associated with graft failure. It is unknown whether transplant recipients also have denatured HLA class II and MICA antibodies. The effects of denatured HLA class I, class II, and MICA antibodies on long-term graft outcome were further investigated based on their ability to fix complement c1q. In this 4-year retrospective cohort study, post-transplant sera from 975 kidney transplant recipients were tested for antibodies against denatured HLA/MICA antigens and these antibodies were further classified based on their ability to fix c1q. Thirty percent of patients had antibodies against denatured HLA class I, II, or MICA antigens. Among them, 8.5% and 21.5% of all patients had c1q-fixing and non c1q-fixing antibodies respectively. There was no significant difference on graft survival between patients with or without antibodies against denatured HLA/MICA. However, when these antibodies were further classified according to their ability to fix c1q, patients with c1q-fixing antibodies had a significantly lower graft survival rate than patients without antibodies or patients with non c1q-fixing antibodies (p=0.008). In 169 patients who lost renal grafts, 44% of them had c1q-fixing antibodies against denatured HLA/MICA antigens, which was significantly higher than that in patients with functioning renal transplants (25%, pantibodies were more significantly associated with graft failure caused by AMR (72.73%) or mixed AMR/CMR (61.9%) as compared to failure due to CMR (35.3%) or other causes (39.2%) (p=0.026). Transplant recipients had antibodies against denatured HLA class I, II, and MICA antigens. However, only c1q-fixing antibodies were associated with graft failure which was related to antibody mediated rejection. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Laboratory and On-Site Tests for Rapid Runway Repair

    Directory of Open Access Journals (Sweden)

    Federico Leonelli

    2017-11-01

    Full Text Available The attention to rapid pavement repair has grown fast in recent decades: this topic is strategic for the airport management process for civil purposes and peacekeeping missions. This work presents the results of laboratory and on-site tests for rapid runway repair, in order to analyse and compare technical and mechanical performances of 12 different materials currently used in airport. The study focuses on site repairs, a technique adopted most frequently than repairs with modular elements. After describing mechanical and physical properties of the examined materials (2 bituminous emulsions, 5 cement mortars, 4 cold bituminous mixtures and 1 expanding resin, the study presents the results of carried out mechanical tests. The results demonstrate that the best performing material is a one-component fast setting and hardening cement mortar with graded aggregates. This material allows the runway reopening 6 h after the work. A cold bituminous mixture (bicomponent premixed cold asphalt with water as catalyst and the ordinary cement concrete allow the reopening to traffic after 18 h, but both ensure a lower service life (1000 coverages than the cement mortar (10,000 coverages. The obtained results include important information both laboratory level and field, and they could be used by airport management bodies and road agencies when scheduling and evaluating pavement repairs.

  9. Incomplete Antibodies May Reduce ABO Cross-Match Incompatibility: A Pilot Study

    Directory of Open Access Journals (Sweden)

    Mehmet Özen

    2018-02-01

    Full Text Available Objective: Any erythrocyte transfusion among humans having type A or B blood groups is impossible due to antibodies causing fatal transfusion complications. A cross-match test is performed to prevent immune transfusion complications before transfusion. Our hypothesis is that the fragment antibody (Fab part of the antibody (incomplete antibody may be used to prevent an immune stimulus related to the complete antibody. Therefore, we designed a pilot study to evaluate the effectiveness of these incomplete antibodies using cross-match tests. Materials and Methods: Pepsin enzyme and staphylococcal protein A columns were used to cut anti-A and anti-B monoclonal antibodies and purify their Fab (2 fragments, respectively. An Rh-positive erythrocyte suspension with purified anti-A Fab (2 solution and B Rh-positive erythrocyte suspension with purified anti-B Fab (2 solution were combined correspondingly. Cross-match tests were performed by tube and gel centrifugation methods. The agglutination levels due to the anti-A and anti-B Fab (2 antibodies and their effects on the agglutination normally observed with complete antibodies were then measured. Results: No agglutination for the purified incomplete anti-A Fab (2 with A Rh+ erythrocyte and anti-B Fab (2 with B Rh+ erythrocyte combinations was observed in the tube cross-match tests. These agglutination levels were 1+ in two wells in the gel centrifugation cross-match tests. Fab (2-treated erythrocytes were also resistant to the agglutination that normally occurs with complete antibodies. Conclusion: We determined that the Fab (2 fragments of antibodies may not only be used to obtain a mild or negative reaction when compared to complete antibodies, but they might also be used for decreasing ABO incompatibility. Incomplete antibodies might be a therapeutic option in autoimmune hemolytic anemia and they may also be used in solid organ or hematopoietic stem cell transplantation. Therefore, we have planned an

  10. Performance of a rapid self-test for detection of Trichomonas vaginalis in South Africa and Brazil

    NARCIS (Netherlands)

    Jones, Heidi E.; Lippman, Sheri A.; Caiaffa-Filho, Helio H.; Young, Taryn; van de Wijgert, Janneke H. H. M.

    2013-01-01

    Women participating in studies in Brazil (n = 695) and South Africa (n = 230) performed rapid point-of-care tests for Trichomonas vaginalis on self-collected vaginal swabs. Using PCR as the gold standard, rapid self-testing achieved high specificity (99.1%; 95% confidence interval [CI], 98.2 to

  11. Evaluation of a new in-clinic test system to detect feline immunodeficiency virus and feline leukemia virus infection.

    Science.gov (United States)

    Sand, Christina; Englert, Theresa; Egberink, Herman; Lutz, Hans; Hartmann, Katrin

    2010-06-01

    Many in-house tests for the diagnosis of feline immunodeficiency virus (FIV) and feline leukemia virus (FeLV) infection are licensed for use in veterinary practice. A new test with unknown performance has recently appeared on the market. The aims of this study were to define the efficacy of a new in-clinic test system, the Anigen Rapid FIV Ab/FeLV Ag Test, and to compare it with the current leading in-clinic test, the SNAP Kombi Plus FeLV Antigen/FIB Antibody Test. Three-hundred serum samples from randomly selected healthy and diseased cats presented to the Clinic of Small Animal Medicine at Ludwig Maximilian University were tested using both the Anigen Rapid Test and the SNAP Kombi Plus Test. Diagnostic sensitivity, specificity, and positive and negative predictive values were calculated for both tests using Western blot as the gold standard for verification of FIV infection and PCR as the gold standard for FeLV infection. The presence of antibodies against FIV was confirmed by Western blot in 9/300 samples (prevalence 3%). FeLV DNA was detected by PCR in 15/300 samples (prevalence 5%). For FIV infection the Anigen Rapid Test had a sensitivity of 88.9%, specificity of 99.7%, positive predictive value of 88.9%, and negative predictive value of 99.7%. For FeLV infection, the Anigen Rapid Test had a sensitivity of 40.0%, specificity of 100%, positive predictive value of 100%, and negative predictive value of 96.9%. Diagnostic accuracy was similar to that of the SNAP Kombi Plus Test. The new Anigen Rapid FIV Ab/FeLV Ag Test performed very well and can be recommended for use in veterinary practice.

  12. Comparative effectiveness of single and dual rapid diagnostic tests for syphilis and HIV in antenatal care services in Colombia.

    Science.gov (United States)

    Gaitán-Duarte, Hernando Guillermo; Newman, Lori; Laverty, Maura; Habib, Ndema Abu; González-Gordon, Lina María; Ángel-Müller, Edith; Abella, Catleya; Barros, Esther Cristina; Rincón, Carlos; Caicedo, Sidia; Gómez, Bertha; Pérez, Freddy

    2016-12-01

    To assess the effectiveness of a dual rapid test compared to a single rapid test for syphilis and HIV screening. A cluster-randomized open-label clinical trial was performed in 12 public antenatal care (ANC) centers in the cities of Bogotá and Cali, Colombia. Pregnant women who were over 14 years of age at their first antenatal visit and who had not been previously tested for HIV and syphilis during the current pregnancy were included. Pregnant women were randomized to single HIV and single syphilis rapid diagnostic tests (Arm A) or to dual HIV and syphilis rapid diagnostic tests (Arm B). The four main outcomes measured were: (1) acceptability of the test, (2) uptake in testing, (3) treatment on the same day (that is, timely treatment), and (4) treatment at any time for positive rapid test cases. Bivariate and multivariate analyses were calculated to adjust for the clustering effect and the period. A total of 1 048 patients were analyzed in Arm A, and 1 166 in Arm B. Acceptability of the rapid tests was 99.8% in Arm A and 99.6% in Arm B. The prevalence of positive rapid tests was 2.21% for syphilis and 0.36% for HIV. Timely treatment was provided to 20 of 29 patients (69%) in Arm A and 16 of 20 patients (80%) in Arm B (relative risk (RR), 1.10; 95% confidence interval (CI): (1.00 -1.20). Treatment at any time was given to 24 of 29 patients (83%) in Arm A and to 20 of 20 (100%) in Arm B (RR, 1.11; 95% CI: 1.01-1.22). There were no differences in patient acceptability, testing and timely treatment between dual rapid tests and single rapid tests for HIV and syphilis screening in the ANC centers. Same-day treatment depends also on the interpretation of and confidence in the results by the health providers.

  13. Comparative effectiveness of single and dual rapid diagnostic tests for syphilis and HIV in antenatal care services in Colombia

    Directory of Open Access Journals (Sweden)

    Hernando Guillermo Gaitán-Duarte

    Full Text Available ABSTRACT Objective To assess the effectiveness of a dual rapid test compared to a single rapid test for syphilis and HIV screening. Methods A cluster-randomized open-label clinical trial was performed in 12 public antenatal care (ANC centers in the cities of Bogotá and Cali, Colombia. Pregnant women who were over 14 years of age at their first antenatal visit and who had not been previously tested for HIV and syphilis during the current pregnancy were included. Pregnant women were randomized to single HIV and single syphilis rapid diagnostic tests (Arm A or to dual HIV and syphilis rapid diagnostic tests (Arm B. The four main outcomes measured were: (1 acceptability of the test, (2 uptake in testing, (3 treatment on the same day (that is, timely treatment, and (4 treatment at any time for positive rapid test cases. Bivariate and multivariate analyses were calculated to adjust for the clustering effect and the period. Results A total of 1 048 patients were analyzed in Arm A, and 1 166 in Arm B. Acceptability of the rapid tests was 99.8% in Arm A and 99.6% in Arm B. The prevalence of positive rapid tests was 2.21% for syphilis and 0.36% for HIV. Timely treatment was provided to 20 of 29 patients (69% in Arm A and 16 of 20 patients (80% in Arm B (relative risk (RR, 1.10; 95% confidence interval (CI: (1.00 −1.20. Treatment at any time was given to 24 of 29 patients (83% in Arm A and to 20 of 20 (100% in Arm B (RR, 1.11; 95% CI: 1.01−1.22. Conclusions There were no differences in patient acceptability, testing and timely treatment between dual rapid tests and single rapid tests for HIV and syphilis screening in the ANC centers. Same-day treatment depends also on the interpretation of and confidence in the results by the health providers.

  14. Detection of avian influenza antibodies and antigens in poultry and ...

    African Journals Online (AJOL)

    Using HI test, the wild birds were negative for AI (H5) antibodies but ELISA detected AI (NP) antibodies in Black Stork (Ciconia nigra) with an overall seroprevalence of 4.5% and mean titre of 24.50±2.400 EU. Cloacal swabs from the same species of wild birds that were tested for antibodies and 710 oropharyngeal swabs ...

  15. Antisporozoite antibodies in mice immunized with irradiation-attenuated Plasmodium berghei sporozoites

    International Nuclear Information System (INIS)

    Hansen, R.; Silva, S.de; Strickland, G.T.

    1979-01-01

    Sera from NMRI/NIH mice were tested for the presence of IgM and IgG anti-sporozoite antibodies using the indirect fluorescent antibody test (IFAT). Both IgM and IgG antibody titres were related to the number of immunizations with irradiation-attenuated Plasmodium berghei sporozoites, and protection from challenge with subsequent non-attenuated sporozoites correlated with the pre-challenge antibody titre. Sera taken five days following challenge showed marked reductions in antibody titres, except for the group receiving the maximum (four) immunizations. Groups immunized with frozen sporozoites or mosquito tissue antigen developed neither antibodies to sporozoites nor protective immunity; nor did animals infected with parasitized blood. However, sera from mice immunized four times with attenuated sporozoites demonstrated IFA titres to blood-stage antigens. The results showed that both IgM and IgG anti-sporozoite antibodies could be detected in mice immunized with attenuated-sporozoites by IFAT, and that the antibody titres correlated with protective immunity. Cross reaction with blood-stage antigens occurred, but the test should still prove useful. (author)

  16. Determination of antinucleic factors and anti-DNA and antibodies with immunefluorescence, radioimmunoassay and latex-test

    Energy Technology Data Exchange (ETDEWEB)

    Lemmel, E M; Hoffmann, R; Botzenhardt, U

    1976-01-01

    The results obtained with the 3 test methods are not completely equal. This is, on the one hand, based on the fact that at least in the fluorescence test other antibodies than in the DNA-compound test are also detected. Quantitatively, however, the two tests show a good correlation to the progress of the illness; strong positive DNA-compound is practically only found in SLE. The authors were able to prove that the addition of purified C1 or C1q components of the complementary system to the test can result in a DNA binding of over 50% and, consequently, in incorrect positive values in the compound test. The Latex test is less suitable for diagnosis and course observation since it relatively often renders negative results at established cases of SLE with distinct illness activity on the one hand, while on the other hand, quantitative evidence, which is desirable for assessing the illness activity, is not possible.

  17. Rapid Detection of Bacillus anthracis Spores Using Immunomagnetic Separation and Amperometry

    Directory of Open Access Journals (Sweden)

    David F. Waller

    2016-12-01

    Full Text Available Portable detection and quantitation methods for Bacillus anthracis (anthrax spores in pure culture or in environmental samples are lacking. Here, an amperometric immunoassay has been developed utilizing immunomagnetic separation to capture the spores and remove potential interferents from test samples followed by amperometric measurement on a field-portable instrument. Antibody-conjugated magnetic beads and antibody-conjugated glucose oxidase were used in a sandwich format for the capture and detection of target spores. Glucose oxidase activity of spore pellets was measured indirectly via amperometry by applying a bias voltage after incubation with glucose, horseradish peroxidase, and the electron mediator 2,2′-azino-bis (3-ethylbenzthiazoline-6-sulphonic acid. Target capture was mediated by polyclonal antisera, whereas monoclonal antibodies were used for signal generation. This strategy maximized sensitivity (500 target spores, 5000 cfu/mL, while also providing a good specificity for Bacillus anthracis spores. Minimal signal deviation occurs in the presence of environmental interferents including soil and modified pH conditions, demonstrating the strengths of immunomagnetic separation. The simultaneous incubation of capture and detection antibodies and rapid substrate development (5 min result in short sample-to-signal times (less than an hour. With attributes comparable or exceeding that of ELISA and LFDs, amperometry is a low-cost, low-weight, and practical method for detecting anthrax spores in the field.

  18. Radioimmunoassay of IgM, IgG, and IgA brucella antibodies

    International Nuclear Information System (INIS)

    Parrett, D.; Nielson, K.H.; White, R.G.; Payne, D.J.H.

    1977-01-01

    A radioimmunoassay (R.I.A.) has been devised to measure the serum antibody against Brucella abortus in each of the immunoglobulin classes IgM, IgG, and IgA. This test was applied to 46 sera from individuals with various clinical types of brucellosis, and the results were compared with the results of conventional direct and indirect agglutination and complement-fixation tests. The R.I.A. provided a highly sensitive primary-type assay which avoided the difficulties with blocking or non-agglutinating antibody, and thus has many advantages in the diagnosis of acute and chronic stages of brucella infection in man. The R.I.A. was successful in detection of antibody in many instances in which conventional serological tests were negative, and such antibody could (if IgM) be associated with acute or (if IgG or IgA) with chronic cases of brucellosis. One case in which B.abortus was isolated by blood culture but which failed to yield antibody by conventional tests, nevertheless showed substantial levels of IgM and IgG antibody by R.I.A. In other cases the R.I.A. test helped to eliminate the diagnosis of brucellosis by revealing absent or low antibody levels. (author)

  19. A Novel, Rapid Assay for Detection and Differentiation of Serotype-Specific Antibodies to Venezuelan Equine Encephalitis Complex Alphaviruses

    National Research Council Canada - National Science Library

    Wang, Eryu; Paessler, Slobodan; Smith, Darci R; Coffey, Lark L; Kang, Wenli; Estrada-Franco, Jose; Weaver, Scott C; Aguilar, Patricia V; Pfeffer, Martin; Olson, James

    2005-01-01

    ... of Venezuelan equine encephalitis (VEE) virus. Two monoclonal antibodies that differentially recognize epizootic versus enzootic VEE virus epitopes were used to measure the serotype-specific blocking abilities of antibodies in sera of naturally...

  20. Development of antibody against sulfamethazine

    International Nuclear Information System (INIS)

    Li Ziying; Xi Wenge; Liu Yibing; Zhang Liling; Guo Weizheng; Han Shiquan

    2004-01-01

    Sulfamethazine (SMT) is widely used to treat bacterial and protozoan infections in food animals. So its residue has been detected in various food products, and in Europe, the tolerance level for sulfonamides in meat and milk is 100 ng/g. To ensure that residues in animal food products do not exceed this limit, a simple, sensitive, and rapid method to determinate their residues in animal tissues is needed. In this paper the development of polyclonal or monoclonal antibodies against sulfamethazine (SMT) and a simplified method to identify residual sulfamethazine by radio immunoassay (RIA) is presented. Polyclonal antibodies (PcAbs) against sulfamethazine (SMT) were obtained by immunizing rabbits with SMT-conjugated bovine serum albumin (BSA). The association constants (Ka) of the PcAbs were higher than 108 and the cross-reactivities with Sulfadiazine(SD), Sulfaquinoxaline(SQX) which were structurally related compounds were lower than 0.05%(RIA). Simultaneous, six strains of hybridoma cell were prepared which can secrete monoclonal antibodies (McAbs) against SMT . The Ka of the McAbs against SMT were higher than 107 and the cross-reactivities with SD, SQX were lower than 0.1%(RIA). (authors)

  1. Rapid drug desensitization for hypersensitivity reactions to chemotherapy and monoclonal antibodies in the 21st century.

    Science.gov (United States)

    Castells Guitart, M C

    2014-01-01

    The frequency of hypersensitivity reactions (HSR) to drugs has risen in the last 10 years owing to increased exposure to better and more allergenic medications including monoclonal antibodies. HSRs prevent patients from using their first-line therapy, leading to decreased quality of life and life expectancy. Although premedication with antihistamines, leukotriene blockers, and corticosteroids can protect against mild-to-moderate HSR, none of these medications has provided protection against anaphylaxis. Rapid drug desensitization is a treatment option for patients with HSR to their first-line medication that protects against anaphylaxis.Although the mechanisms of drug desensitization are not completely understood, in vitro mast cell models of IgE antigen desensitization have led to the design of safe and effective in vivo protocols aimed at protecting highly sensitized patients from hypersensitivity reactions and anaphylaxis. This review provides an insight into the mechanisms of IgE/mast cell desensitization, the principles and practice of drug desensitization, and an overview of the different desensitization protocols and their safety and efficacy profiles. Drug desensitization should only be performed by allergists, trained nurses, and experienced pharmacists, since this high-risk procedure involves reintroducing allergenic medication to highly sensitized patients, with the consequent potential for severe or fatal HSRs.

  2. Evaluation of dengue NS1 antigen rapid tests and ELISA kits using clinical samples.

    Directory of Open Access Journals (Sweden)

    Subhamoy Pal

    Full Text Available Early diagnosis of dengue virus (DENV infection can improve clinical outcomes by ensuring close follow-up, initiating appropriate supportive therapies and raising awareness to the potential of hemorrhage or shock. Non-structural glycoprotein-1 (NS1 has proven to be a useful biomarker for early diagnosis of dengue. A number of rapid diagnostic tests (RDTs and enzyme-linked immunosorbent assays (ELISAs targeting NS1 antigen (Ag are now commercially available. Here we evaluated these tests using a well-characterized panel of clinical samples to determine their effectiveness for early diagnosis.Retrospective samples from South America were used to evaluate the following tests: (i "Dengue NS1 Ag STRIP" and (ii "Platelia Dengue NS1 Ag ELISA" (Bio-Rad, France, (iii "Dengue NS1 Detect Rapid Test (1st Generation" and (iv "DENV Detect NS1 ELISA" (InBios International, United States, (v "Panbio Dengue Early Rapid (1st generation" (vi "Panbio Dengue Early ELISA (2nd generation" and (vii "SD Bioline Dengue NS1 Ag Rapid Test" (Alere, United States. Overall, the sensitivity of the RDTs ranged from 71.9%-79.1% while the sensitivity of the ELISAs varied between 85.6-95.9%, using virus isolation as the reference method. Most tests had lower sensitivity for DENV-4 relative to the other three serotypes, were less sensitive in detecting secondary infections, and appeared to be most sensitive on Day 3-4 post symptom onset. The specificity of all evaluated tests ranged from 95%-100%.ELISAs had greater overall sensitivity than RDTs. In conjunction with other parameters, the performance data can help determine which dengue diagnostics should be used during the first few days of illness, when the patients are most likely to present to a clinic seeking care.

  3. Associations among immunological, parasitological and clinical parameters in canine visceral leishmaniasis: Emaciation, spleen parasitism, specific antibodies and leishmanin skin test reaction.

    Science.gov (United States)

    Dos-Santos, W L C; Jesus, E E; Paranhos-Silva, M; Pereira, A M; Santos, J C; Baleeiro, C O; Nascimento, E G; Moreira, E D; Oliveira, G G S; Pontes-de-Carvalho, L C

    2008-06-15

    Associations among parameters commonly used as markers of infection by Leishmania sp., or of susceptibility to visceral leishmaniasis, were investigated in 325 stray dogs from an area where this disease is endemic. Evidence of infection (presence of Leishmania in splenic cultures, positive leishmanin skin test (LST) or detection of anti-Leishmania antibody activity in the serum) was found in 57% of the animals. Both evidence of weight loss (chi(2)-test, P=0.0005) and presence of specific antibody activity in the serum (chi(2)-test, Ptest results and emaciation (chi(2), P=0.0089). Furthermore, animals with positive splenic cultures and negative leishmanin skin test results had higher levels of total serum IgG (Kruskal-Wallis test, P=0.001) and IgG2 (Kruskal-Wallis test, P=0.05) than animals with negative splenic cultures, and were more emaciated than animals with negative LST results and positive splenic cultures. The data presented herein suggest that associating these common parameters may improve their performance in predicting susceptibility to canine visceral leishmaniasis.

  4. Staphylococcal enterotoxin-specific IgE antibodies in atopic dermatitis.

    Science.gov (United States)

    Ide, Fumihito; Matsubara, Tomoyo; Kaneko, Miho; Ichiyama, Takashi; Mukouyama, Tokuko; Furukawa, Susumu

    2004-06-01

    The authors clarified the clinical significance of the measurement of serum concentrations of specific IgE antibodies to staphylococcal enterotoxin (SE) A- and SEB in atopic dermatitis (AD). The serum concentrations of SEA- and SEB-specific IgE antibodies in 140 pediatric patients with AD were measured with an immuno CAP -radioallergosorbent test system (RAST). To check the cross-reaction of specific IgE antibodies to SEA/SEB and other allergens, the CAP RAST fluorescent enzyme immunoassay inhibition test was performed. Forty-seven patients (33.6%) tested positive for either SEA- or SEB-specific IgE antibodies. School children showed higher positive rates of SEA/SEB-specific IgE antibodies than infants or young children. The patients with severe AD and those with exacerbation of symptoms in summer, had higher positive rates of SEA/SEB-specific IgE antibodies than patients with mild AD or those with exacerbation in winter. In addition, the positive rates of specific IgE antibodies to both dog-dander and cat-dander were higher in patients with positive SEA/SEB-specific IgE antibodies than in patients with negative ones. No cross-reactions occurred among specific IgE antibodies to SEA/SEB and dog/cat dander with one patient's serum, which had positive IgE-specific antibodies against cat/dog dander and SEA/SEB. The positive rate of SEA/SEB-specific IgE antibodies in the patients with dogs and/or cats as pets was 48.4%, which was higher than in those with no pets. Atopic dermatitis patients who exhibit high positive rates of SEA/SEB-specific IgE antibodies were found to be school children, severe cases, cases with high serum concentrations of total IgE, cases with exacerbation in summer, and cases with dogs and/or cats as pets. The measurement of serum concentrations of specific IgE antibodies to SEA and SEB, thus has some value for evaluating AD patients.

  5. Simultaneous quantitative detection of multiple tumor markers with a rapid and sensitive multicolor quantum dots based immunochromatographic test strip.

    Science.gov (United States)

    Wang, Chunying; Hou, Fei; Ma, Yicai

    2015-06-15

    A novel multicolor quantum dots (QDs) based immunochromatographic test strip (ICTS) was developed for simultaneous quantitative detection of multiple tumor markers, by utilizing alpha fetoprotein (AFP) and carcinoembryonic antigen (CEA) as models. The immunosensor could realize simultaneous quantitative detection of tumor markers with only one test line and one control line on the nitrocellulose membrane (NC membrane) due to the introduction of multicolor QDs. In this method, a mixture of mouse anti-AFP McAb and mouse anti-CEA McAb was coated on NC membrane as test line and goat anti-mouse IgG antibody was coated as control line. Anti-AFP McAb-QDs546 conjugates and anti-CEA McAb-QDs620 conjugates were mixed and applied to the conjugate pad. Simultaneous quantitative detection of multiple tumor markers was achieved by detecting the fluorescence intensity of captured QDs labels on test line and control line using a test strip reader. Under the optimum conditions, AFP and CEA could be detected as low as 3 ng/mL and 2 ng/mL in 15 min with a sample volume of 80 μL, and no obvious cross-reactivity was observed. The immunosensor was validated with 130 clinical samples and in which it exhibited high sensitivity (93% for AFP and 87% for CEA) and specificity (94% for AFP and 97% for CEA). The immunosensor also demonstrated high recoveries (87.5-113% for AFP and 90-97.3% for CEA) and low relative standard deviations (RSDs) (2.8-6.2% for AFP and 4.9-9.6% for CEA) when testing spiked human serum. This novel multicolor QDs based ICTS provides an easy and rapid, simultaneous quantitative detecting strategy for point-of-care testing of tumor markers. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. [Attempt for development of rapid word reading test for children--evaluation of reliability and validity].

    Science.gov (United States)

    Hashimoto, Ryusaku; Kashiwagi, Mitsuru; Suzuki, Shuhei

    2008-09-01

    We developed a rapid word reading test for examining the phonological processing ability of Japanese children. We prepared two versions of the test, version A and B. Each test has word and non-word tasks. Twenty-two healthy boys of third grade in primary schools participated in this validation study. For criterion related validity, we performed the serial Hiragana reading test, the sentence reading test, Raven's coloured progressive matrices (RCPM), the Token test for children, the Kana word dictation test, the standardized comprehension test of abstract words (SCTAW), and Trail Circle test. The reading times of the newly developed test correlated moderately or highly with those of the serial Hiragana reading test and the sentence reading test. However, the scores of the other tests (RCPM, Token test for children, Kana word dictation test, SCTAW, Trail Circle test) did not correlated with the reading time of the rapid word reading test. Test-retest reliabilities in the word tasks were more than moderate: 0.52 and 0.76 in versions A and B, while those in the non-word tasks were high: 0.91 and 0.88 in versions A and B. The correlation coefficient between versions A and B was 0.7 for the word tasks and 0.92 for the non-word tasks. This study showed that the rapid word reading test has substantial validity and reliability for testing the phonological processing ability of Japanese children. In addition, the non-word tasks were more suitable for selectively examining the speed of the grapheme to phoneme conversion process.

  7. Sero-prevalence of virus neutralizing antibodies for rabies in different groups of dogs following vaccination.

    Science.gov (United States)

    Pimburage, R M S; Gunatilake, M; Wimalaratne, O; Balasuriya, A; Perera, K A D N

    2017-05-18

    Mass vaccination of dogs is considered fundamental for national rabies control programmes in Sri Lanka, as dog is the main reservoir and transmitter of the disease. Dogs were followed to determine the sero-prevalence of antibodies to the rabies virus. Altogether 510 previously vaccinated and unvaccinated dogs with owners (domestic dogs) and dogs without owners (stray dogs) of the local guard dog breed in different age groups recruited from Kalutara District, Sri Lanka. The dogs were vaccinated with a monovalent inactivated vaccine intramuscularly and serum antibody titres on days 0, 30, 180 and 360 were determined by the Rapid Fluorescent Focus Inhibition Test (RFFIT). The results indicated, a single dose of anti-rabies vaccination fails to generate a protective level of immunity (0.5 IU/ml) which lasts until 1 year in 40.42% of dogs without owners and 57.14% of previously unvaccinated juvenile (age: 3 months to 1 year) dogs with owners. More than one vaccination would help to maintain antibody titres above the protective level in the majority of dogs. The pattern of antibody titre development in annually vaccinated and irregularly vaccinated (not annual) adult dogs with owners is closely similar irrespective of regularity in vaccination. Previously vaccinated animals have higher (2 IU/ml) antibody titres to begin with and have a higher antibody titre on day 360 too. They show a very good antibody titre by day 180. Unvaccinated animals start with low antibody titre and return to low titres by day 360, but have a satisfactory antibody titre by day 180. A single dose of anti-rabies vaccination is not sufficient for the maintenance of antibody titres for a period of 1 year in puppies, juvenile dogs with owners and in dogs without owners. Maternal antibodies do not provide adequate protection to puppies of previously vaccinated dams and puppies of previously unvaccinated dams. Immunity development after vaccination seems to be closely similar in both the groups

  8. Screening individual hybridomas by microengraving to discover monoclonal antibodies

    Science.gov (United States)

    Ogunniyi, Adebola O; Story, Craig M; Papa, Eliseo; Guillen, Eduardo; Love, J Christopher

    2014-01-01

    The demand for monoclonal antibodies (mAbs) in biomedical research is significant, but the current methodologies used to discover them are both lengthy and costly. Consequently, the diversity of antibodies available for any particular antigen remains limited. Microengraving is a soft lithographic technique that provides a rapid and efficient alternative for discovering new mAbs. This protocol describes how to use microengraving to screen mouse hybridomas to establish new cell lines producing unique mAbs. Single cells from a polyclonal population are isolated into an array of microscale wells (~105 cells per screen). The array is then used to print a protein microarray, where each element contains the antibodies captured from individual wells. The antibodies on the microarray are screened with antigens of interest, and mapped to the corresponding cells, which are then recovered from their microwells by micromanipulation. Screening and retrieval require approximately 1–3 d (9–12 d including the steps for preparing arrays of microwells). PMID:19528952

  9. Rapid antibiotic susceptibility testing of Mycobacterium tuberculosis : Its utility in resource poor settings

    Directory of Open Access Journals (Sweden)

    Poojary A

    2006-01-01

    Full Text Available Purpose: To compare the rapid colorimetric nitrate reductase based antibiotic susceptibility (CONRAS test performed on Mycobacterium tuberculosis isolates with the conventional method i.e., the proportion method. Methods: One hundred clinical isolates of M. tuberculosis were tested for susceptibility to isoniazid (INH and rifampicin (RIF by the conventional proportion method and CONRAS in Middlebrook 7H9 liquid medium enriched with growth supplements (MB7H9S. Results: The performance of the CONRAS test was evaluated using proportion method as the gold standard. The sensitivity (ability to detect true drug resistance and specificity (ability to detect true drug susceptibility of the CONRAS test to INH was 93.75 and 98.52% and for RIF it was 96.10 and 100% respectively. The mean time for reporting was 6.3 days and the test showed excellent reproducibility. The kappa (k value for INH was 0.92 and for RIF was 0.99, indicating excellent agreement between the two methods. Conclusions: CONRAS test is a rapid and reliable method of drug susceptibility for M. tuberculosis.

  10. Case report: lymphogranuloma venereum proctitis-from rapid screening to molecular confirmation of a masked sexually transmitted disease.

    Science.gov (United States)

    Markowicz, Mateusz; Grilnberger, Evelyn; Huber, Florian; Leibl, Gabriele; Abrahamian, Heidemarie; Gartner, Manfred; Huber, Monika; Chott, Andreas; Reiter, Michael; Stanek, Gerold

    2013-08-01

    Proctitis caused by Chlamydia trachomatis L2b can manifest with very mild, nonspecific symptoms, and appropriate diagnostic evaluation is crucial. The case report demonstrates that rapid screening test, detection of specific antibodies in serum, and direct pathogen identification by PCR performed on tissue sample or rectal swab allow successful diagnosis of the still emerging sexually transmitted disease among homosexual patients. Copyright © 2013 Elsevier Inc. All rights reserved.

  11. Feasibility of supervised self-testing using an oral fluid-based HIV rapid testing method: a cross-sectional, mixed method study among pregnant women in rural India

    OpenAIRE

    Sarkar, Archana; Mburu, Gitau; Shivkumar, Poonam Varma; Sharma, Pankhuri; Campbell, Fiona; Behera, Jagannath; Dargan, Ritu; Mishra, Surendra Kumar; Mehra, Sunil

    2016-01-01

    Introduction: HIV self-testing can increase coverage of essential HIV services. This study aimed to establish the acceptability, concordance and feasibility of supervised HIV self-testing among pregnant women in rural India. Methods: A cross-sectional, mixed methods study was conducted among 202 consenting pregnant women in a rural Indian hospital between August 2014 and January 2015. Participants were provided with instructions on how to self-test using OraQuick® HIV antibody test, and subse...

  12. Rapid testing may not improve uptake of HIV testing and same day results in a rural South African community: a cohort study of 12,000 women.

    Directory of Open Access Journals (Sweden)

    Ntombizodumo B Mkwanazi

    Full Text Available Rapid testing of pregnant women aims to increase uptake of HIV testing and results and thus optimize care. We report on the acceptability of HIV counselling and testing, and uptake of results, before and after the introduction of rapid testing in this area.HIV counsellors offered counselling and testing to women attending 8 antenatal clinics, prior to enrolment into a study examining infant feeding and postnatal HIV transmission. From August 2001 to April 2003, blood was sent for HIV ELISA testing in line with the Prevention of Mother-to-Child Transmission (PMTCT programme in the district. From May 2003 to September 2004 women were offered a rapid HIV test as part of the PMTCT programme, but also continued to have ELISA testing for study purposes. Of 12,323 women counselled, 5,879 attended clinic prior to May 2003, and 6,444 after May 2003 when rapid testing was introduced; of whom 4,324 (74.6% and 4,810 (74.6% agreed to have an HIV test respectively. Of the 4,810 women who had a rapid HIV test, only 166 (3.4% requested to receive their results on the same day as testing, the remainder opted to return for results at a later appointment. Women with secondary school education were less likely to agree to testing than those with no education (AOR 0.648, p35 years (AOR 0.756, p<0.01 compared to those <20 years.Contrary to other reports, few women who had rapid tests accepted their HIV results the same day. Finding strategies to increase the proportion of pregnant women knowing their HIV results is critical so that appropriate care can be given.

  13. Efficacy comparative of different laboratory test reagents for hepatitis C virus antibody

    Directory of Open Access Journals (Sweden)

    GUO Feibo

    2016-09-01

    Full Text Available Objective To investigate the effects of different laboratory test reagents for hepatitis C virus (HCV antibody through a comparative analysis. Methods A total of 207 samples which tested positive by four anti-HCV screening reagents commonly used in the laboratories in China (Kehua, Xinchuang, Wantai, and Abbott were included. HCV RNA nucleic acid amplification (NAT was performed, and if NAT results were negative, recombinant immunoblot assay (RIBA was performed for further confirmation. The test results of these four screening reagents were compared, and their S/CO values and true positive rates were analyzed. Results Of all the 205 samples testing positive by any one reagent, 191 (93.2% tested positive by the four reagents, and 14 (6.8% were tested inconsistently by the four reagents. The positive predictive values of Xinchuang, Kehua, Wantai, and Abbott reagents were 88.2% (180/204, 93.8% (180/192, 91.4% (180/197, and 90.0% (180/200, respectively. The S/CO thresholds with a positive predictive value of ≥95% for Xinchuang, Kehua, Wantai, and Abbott reagents were 9.0, 4.0, 5.0, and 7.0, respectively. Conclusion Xinchuang, Kehua, Wantai, and Abbott reagents have significantly different S/CO thresholds with a positive predictive value of ≥95%, which are significantly different from those in other domestic laboratories. Each laboratory should establish an applicable S/CO threshold with a positive predictive value of ≥95%, in order to reduce the sample size for confirmatory test.

  14. APTES Functionalized Iron Oxide-Silver Magnetic Hetero-Nanocomposites for Selective Capture and Rapid Removal of Salmonella enteritidis from Aqueous Solution

    Science.gov (United States)

    Trang, Vu Thi; Dinh, Ngo Xuan; Lan, Hoang; Tam, Le Thi; Huy, Tran Quang; Tuan, Pham Anh; Phan, Vu Ngoc; Le, Anh-Tuan

    2018-02-01

    Magnetic nanomaterials, as a promising platform for the fast and sensitive detection of bacterial pathogens, have attracted increasing interest from researchers in recent years. In this work, by utilizing a two-step synthetic technique consisting of co-precipitation and subsequent hydrothermal reaction, followed by functionalization steps with (3-aminopropyl)triethoxysilane (APTES) and the antibody against Salmonella enteritidis, antibody-conjugated Fe3O4-Ag@APTES hetero-nanocomposites were successfully prepared. Due to the specific antibody, the developed Fe3O4-Ag@APTES@SE-Ab conjugates are capable of selectively capturing S. enteritidis at a low concentration of about 101 CFU/mL. Moreover, the prepared magnetic conjugates also revealed that the S. enteritidis could be rapidly removed from water solution in 20 min by using an external magnetic field with a removal efficiency obtained of ˜ 91.36%. These results indicated that the Fe3O4-Ag@APTES@SE-Ab conjugates are promising for the rapid selective capture and removal of bacterial pathogens from aqueous environments, and can be used for improving the detection quality of pathogens in water samples using immunosensor-based diagnostic tests.

  15. Detection of anti-lactoferrin antibodies and anti-myeloperoxidase antibodies in autoimmune hepatitis: a retrospective study.

    Science.gov (United States)

    Tan, Liming; Zhang, Yuhong; Peng, Weihua; Chen, Juanjuan; Li, Hua; Ming, Feng

    2014-01-01

    Anti-lactoferrin antibodies (ALA) and anti-myeloperoxidase antibodies (AMPA) are specific serological markers for autoimmune hepatitis (AIH). The project aimed to detect ALA and AMPA and explore their clinical significances in AIH patients. 59 AIH patients, 217 non AIH patients, and 50 healthy controls were enrolled in this study. ALA and AMPA were detected by ELISA. Antineutropil cytoplasmic antibodies (ANCA) and anti-smooth muscle antibodies (ASMA) were examined by indirect immunofluorescence. Antimitochondrial antibody M2 subtype (AMA-M2), anti-liver kidney microsomal antibody Type 1 (LKM1), anti-liver cytosol antibody Type 1 (LC1), and anti-soluble liver antigen/liver-pancreas antibodies (SLA/LP) were tested by immunoblot. The positivity for ALA was 18.6% in AIH group, only one patient in non-AIH group was positive for ALA; the positivity for AMPA was 59.3% in AIH group, with significant differences (P < 0.01) compared with other groups. The specificities for ALA and AMPA were 99.63% and 97.75%; the sensitivities were 18.64% and 59.32%; and the accuracy rates were 84.97% and 90.80%, respectively. A certain correlation was observed between ALA and SLA/LP, AMPA and ANCA, ASMA in AIH group. ALA and AMPA were associated with AIH, and had high clinical diagnostic value. Co-detection with other relative autoantibodies could play an important role in differential diagnosis of AIH.

  16. Assessment of the Diagnostic Potential of Clinotech TB Screen Test ...

    African Journals Online (AJOL)

    The Clinotech TB Screen test, a 3rd generation multi-antigen rapid chromatographic immunoassay for detection of IgG antibodies in serum against recombinant protein antigens 38kDa, 16kDa and 6kDa, was assessed for its diagnostic potential for diagnosis of active pulmonary TB in routine TB control programme in Abia ...

  17. Characterization of novel monoclonal antibodies against the MERS-coronavirus spike protein and their application in species-independent antibody detection by competitive ELISA.

    Science.gov (United States)

    Fukushi, Shuetsu; Fukuma, Aiko; Kurosu, Takeshi; Watanabe, Shumpei; Shimojima, Masayuki; Shirato, Kazuya; Iwata-Yoshikawa, Naoko; Nagata, Noriyo; Ohnishi, Kazuo; Ato, Manabu; Melaku, Simenew Keskes; Sentsui, Hiroshi; Saijo, Masayuki

    2018-01-01

    Since discovering the Middle East respiratory syndrome coronavirus (MERS-CoV) as a causative agent of severe respiratory illness in the Middle East in 2012, serological testing has been conducted to assess antibody responses in patients and to investigate the zoonotic reservoir of the virus. Although the virus neutralization test is the gold standard assay for MERS diagnosis and for investigating the zoonotic reservoir, it uses live virus and so must be performed in high containment laboratories. Competitive ELISA (cELISA), in which a labeled monoclonal antibody (MAb) competes with test serum antibodies for target epitopes, may be a suitable alternative because it detects antibodies in a species-independent manner. In this study, novel MAbs against the spike protein of MERS-CoV were produced and characterized. One of these MAbs was used to develop a cELISA. The cELISA detected MERS-CoV-specific antibodies in sera from MERS-CoV-infected rats and rabbits immunized with the spike protein of MERS-CoV. The MAb-based cELISA was validated using sera from Ethiopian dromedary camels. Relative to the neutralization test, the cELISA detected MERS-CoV-specific antibodies in 66 Ethiopian dromedary camels with a sensitivity and specificity of 98% and 100%, respectively. The cELISA and neutralization test results correlated well (Pearson's correlation coefficients=0.71-0.76, depending on the cELISA serum dilution). This cELISA may be useful for MERS epidemiological investigations on MERS-CoV infection. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Immunoradiometric assay for cytomegalovirus-specific IgG antibodies

    International Nuclear Information System (INIS)

    Klapper, P.E.; Cleator, G.M.; Prinja-Wolks, D.; Morris, D.J.

    1990-01-01

    An immunoradiometric assay (radio-immunosorbent test; RIST) for the detection of IgG antibodies to human herpesvirus 4 [human cytomegalovirus (CMV)] has been developed. The technique utilizes CMV antigen passively adsorbed to a polyvinyl microtitration plate and a radiolabelled murine monoclonal anti-human IgG antibody to detect binding of human antibody to the 'solid phase' reagent. The assay was optimized, and its specifity confirmed by testing paired acute and convalescent sera from patients with acute CMV or other human herpesvirus infections. To determine the assay's sensitivity 1433 blood donor sera were examined. The RIST was more sensitive than a standard complement fixation (CFT). Use of a monoclonal anti-human IgG antibody in the RIST reduced non-specific binding to the control uninfected cell antigen such that blood donor sera could be tested in the assay using only a CMV antigen without generating an unacceptable false positive rate. (author). 23 refs.; 1 tab

  19. Evaluation of nine HIV rapid test kits to develop a national HIV testing algorithm in Nigeria

    Directory of Open Access Journals (Sweden)

    Orji Bassey

    2015-05-01

    Full Text Available Background: Non-cold chain-dependent HIV rapid testing has been adopted in many resource-constrained nations as a strategy for reaching out to populations. HIV rapid test kits (RTKs have the advantage of ease of use, low operational cost and short turnaround times. Before 2005, different RTKs had been used in Nigeria without formal evaluation. Between 2005 and 2007, a study was conducted to formally evaluate a number of RTKs and construct HIV testing algorithms. Objectives: The objectives of this study were to assess and select HIV RTKs and develop national testing algorithms. Method: Nine RTKs were evaluated using 528 well-characterised plasma samples. These comprised 198 HIV-positive specimens (37.5% and 330 HIV-negative specimens (62.5%, collected nationally. Sensitivity and specificity were calculated with 95% confidence intervals for all nine RTKs singly and for serial and parallel combinations of six RTKs; and relative costs were estimated. Results: Six of the nine RTKs met the selection criteria, including minimum sensitivity and specificity (both ≥ 99.0% requirements. There were no significant differences in sensitivities or specificities of RTKs in the serial and parallel algorithms, but the cost of RTKs in parallel algorithms was twice that in serial algorithms. Consequently, three serial algorithms, comprising four test kits (BundiTM, DetermineTM, Stat-Pak® and Uni-GoldTM with 100.0% sensitivity and 99.1% – 100.0% specificity, were recommended and adopted as national interim testing algorithms in 2007. Conclusion: This evaluation provides the first evidence for reliable combinations of RTKs for HIV testing in Nigeria. However, these RTKs need further evaluation in the field (Phase II to re-validate their performance.

  20. Next Generation Antibody Therapeutics Using Bispecific Antibody Technology.

    Science.gov (United States)

    Igawa, Tomoyuki

    2017-01-01

    Nearly fifty monoclonal antibodies have been approved to date, and the market for monoclonal antibodies is expected to continue to grow. Since global competition in the field of antibody therapeutics is intense, we need to establish novel antibody engineering technologies to provide true benefit for patients, with differentiated product values. Bispecific antibodies are among the next generation of antibody therapeutics that can bind to two different target antigens by the two arms of immunoglobulin G (IgG) molecule, and are thus believed to be applicable to various therapeutic needs. Until recently, large scale manufacturing of human IgG bispecific antibody was impossible. We have established a technology, named asymmetric re-engineering technology (ART)-Ig, to enable large scale manufacturing of bispecific antibodies. Three examples of next generation antibody therapeutics using ART-Ig technology are described. Recent updates on bispecific antibodies against factor IXa and factor X for the treatment of hemophilia A, bispecific antibodies against a tumor specific antigen and T cell surface marker CD3 for cancer immunotherapy, and bispecific antibodies against two different epitopes of soluble antigen with pH-dependent binding property for the elimination of soluble antigen from plasma are also described.