WorldWideScience

Sample records for rapid antibody tests

  1. A rapid ultrasound particle agglutination method for HIV antibody detection: Comparison with conventional rapid HIV tests.

    Science.gov (United States)

    Bystryak, Simon; Ossina, Natalya

    2017-11-01

    We present the results of the feasibility and preliminary studies on analytical performance of a rapid test for detection of human immunodeficiency virus (HIV) antibodies in human serum or plasma that is an important advance in detecting HIV infection. Current methods for rapid testing of antibodies against HIV are qualitative and exhibit poor sensitivity (limit of detection). In this paper, we describe an ultrasound particle agglutination (UPA) method that leads to a significant increase of the sensitivity of conventional latex agglutination tests for HIV antibody detection in human serum or plasma. The UPA method is based on the use of: 1) a dual mode ultrasound, wherein a first single-frequency mode is used to accelerate the latex agglutination process, and then a second swept-frequency mode of sonication is used to disintegrate non-specifically bound aggregates; and 2) a numerical assessment of results of the agglutination process. The numerical assessment is carried out by optical detection and analysis of moving patterns in the resonator cell during the swept-frequency mode. The single-step UPA method is rapid and more sensitive than the three commercial rapid HIV test kits analyzed in the study: analytical sensitivity of the new UPA method was found to be 510-, 115-, and 80-fold higher than that for Capillus™, Multispot™ and Uni-Gold™ Recombigen HIV antibody rapid test kits, respectively. The newly developed UPA method opens up additional possibilities for detection of a number of clinically significant markers in point-of-care settings. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. [Development of a rapid test kit for antibody to HIV by nano immunomagnetic lateral flow method].

    Science.gov (United States)

    Yang, Fa-qing; Lee, Tony; Wang, Chao-nan; Sun, Shu-ye; Li, Shan-shan; Tian, Hui

    2010-06-01

    To develop a rapid test kit for antibody to HIV by nano immunomagnetic lateral flow method. A rapid test kit was developed by conjugation of the HIV antigen gp41 and gp36 to 200nm super paramagnetic particles by carbodiimide (EDC) and coating of the HIV antigen gp41 and gp36 to nitrocellulose membrane. Then the kit was evaluated with serials of experiments. The kit was qualified with examination of national reference panel of anti-HIV antibody for colloidal gold diagnostic kit. The sensitivity was 100% by tested with 20 HIV antibody positive sera, the specificity was 98.5% by tested with 600 HIV antibody negative sera, respectively. The stability of the kit was over 12 month by storage at room temperature. A diagnostic kit for antibody to HIV was developed with the advantages of convenience, rapid test, good stability and point of care.

  3. Evaluation of a Rapid Immunochromatographic Treponemal Antibody Test Comparing the Treponema Pallidum Particle Agglutination Assay.

    Science.gov (United States)

    Lee, Jong-Han; Lim, Chae Seung; Lee, Min-Geol; Kim, Hyon-Suk

    2015-09-01

    In addition to conventional tests, several methods for detection of treponema-specific antibodies in clinical settings have been recently introduced. We aim to comparatively evaluate a rapid immunochromatographic test (ICT) for Treponema pallidum specific antibody (SD Bioline Syphilis 3.0) and the T. pallidum particle agglutination (TPPA) assay. In all, 132 serum samples from 78 syphilis patients and 54 syphilis-negative controls were analyzed. SD Bioline Syphilis 3.0 test (Standard Diagnostic, Inc., Yongin, Korea) was evaluated and compared to Serodia TPPA assay (Fujirebio, Inc., Tokyo, Japan). All discrepant results between the two assays were repeatedly tested and evaluated by the fluorescent treponemal antibody-absorption (FTA-ABS) assay. Test reproducibility and 95% limit of detection of SD Bioline Syphilis 3.0 were determined across three different lots for seven consecutive days in triplicate. Interference due to autoantibodies and pregnancy was also tested. Percent agreement between SD Bioline Syphilis 3.0 and TPPA assays was 99.2%. Sensitivity and specificity were 100%, respectively. In TPPA assay, test-to-test, day-to-day, and lot-to-lot variations were not identified until 1:320 titer (eightfold dilutions). There was no interference due to the presence of antinuclear antibodies or samples or pregnancy. Percent agreement of SD Syphilis 3.0 and TPPA was very good. Sensitivity and specificity were appropriate for T. pallidum antibody detection. Thus, a rapid ICT could be suitable for syphilis antibody detection. © 2014 Wiley Periodicals, Inc.

  4. Comparison of a rapid immunochromatographic assay with an immunofluorescent antibody test for detection of Leishmania infantum antibodies in dogs.

    Science.gov (United States)

    Proverbio, Daniela; Spada, Eva; Perego, Roberta; Baggiani, Luciana; Bagnagatti De Giorgi, Giada; Migliazzo, Antonella; Vitale, Fabrizio

    2016-12-01

    Identification of Leishmania infantum-infected dogs is crucial for control of canine leishmaniosis. In particular, in areas where access to specialized laboratories is limited, the availability of reliable and rapid in-clinic serologic tests may support immediate diagnosis in suspected cases and permit detection of asymptomatic canine carriers of L infantum infection. The purpose of the study was to validate the immunochromatographic test (ICT) Anigen Rapid Leishmania Ab Test kit for detection of L infantum antibodies in naturally exposed dogs in comparison with the immunofluorescence antibody test (IFAT). Serum samples from 66 dogs, including 20 healthy control dogs and 46 dogs suspected or confirmed with canine leishmaniosis, were measured by both tests. Anti-Leishmania IgG titers ≥ 1:40 by IFAT were considered positive. Kappa statistic with a 95% CI was calculated to evaluate agreement between the 2 testing methods, and sensitivity, specificity, and positive and negative likelihood ratio were calculated. Anti-L infantum IgG antibodies were found in 35 of 66 samples using the IFAT test (titers 1:40-1:5120). Thirty-one out of 66 samples tested positive with the qualitative ICT. Four IFAT-positive (titers ICT-negative. The Kappa value of 0.853 demonstrated very good agreement between the 2 tests. The Anigen Rapid Leishmania Ab Test kit reliably identified canine sera with anti-L infantum IgG antibody titers ≥ 1:40. The ICT requires neither special preparation of the serum nor specialized equipment and can be stored at ambient temperature. The test is applicable as a field test because it is easy to use and provides rapid results. © 2016 American Society for Veterinary Clinical Pathology.

  5. Sensitivity of a rapid immuno-chromatographic test for hepatitis C antibodies detection.

    Science.gov (United States)

    Desbois, Delphine; Vaghefi, Parissa; Savary, Jeanine; Dussaix, Elisabeth; Roque-Afonso, Anne-Marie

    2008-02-01

    Enzyme-linked immunoassays (ELISA) are the most widely used anti-hepatitis C virus (HCV) screening tests but simple, instrument and electricity-free screening tests have been developed with results available in a few minutes. The sensitivity of a rapid immuno-chromatographic assay for the detection of anti-HCV antibodies was evaluated on 421 HCV RNA-positive samples from chronic carriers and compared with ELISA method. The sensitivity of the ELISA method was 99.3% and the sensitivity of the rapid test was 95.5%. False negative results were independent of HCV genotype, but were associated with human immunodeficiency virus (HIV)-positive status. Among HIV-negative people, sensitivities of the rapid test and the EIA assay were 99.2% and 100%, respectively. Whereas among HIV-positive people, sensitivities were 77.5% and 96.3%. The immuno-chromatographic test is rapid and simple, and could be used along with rapid anti-HIV determination, in settings with limited facilities or when rapid results are required.

  6. Preclinical and clinical performance of the Efoora test, a rapid test for detection of human immunodeficiency virus-specific antibodies.

    Science.gov (United States)

    Arens, Max Q; Mundy, Linda M; Amsterdam, Daniel; Barrett, J Tom; Bigg, Dan; Bruckner, David; Hanna, Bruce; Prince, Harry; Purington, Timothy; Hanna, Todd; Hewitt, Ross; Kalinka, Carolyn; Koppes, Thomas; Maxwell, Sarz; Moe, Ardis; Doymaz, Mehmet; Poulter, Melinda; Saber-Tehrani, Maryam; Simard, Lorenzo; Wilkins-Carmody, Donna; Vidaver, John; Berger, Cheryl; Davis, Alan H; Alzona, Mortimer T

    2005-05-01

    Barriers to effective diagnostic testing for human immunodeficiency virus type 1 (HIV-1) infection can be reduced with simple, reliable, and rapid detection methods. Our objective was to determine the accuracy, sensitivity, and specificity of a new rapid, lateral-flow immunochromatographic HIV-1 antibody detection device. Preclinical studies were performed using seroconversion, cross-reaction, and interference panels, archived clinical specimens, and fresh whole blood. In a multicenter, prospective clinical trial, a four-sample matrix of capillary (fingerstick) whole-blood specimens and venous whole blood, plasma, and serum was tested for HIV-1 antibodies with the Efoora HIV rapid test (Efoora Inc., Buffalo Grove, IL) and compared with an enzyme immunoassay (EIA) (Abbott Laboratories) licensed by the Food and Drug Administration. Western blot and nucleic acid test supplemental assays were employed to adjudicate discordant samples. Preclinical testing of seroconversion panels showed that antibodies were often detected earlier by the rapid test than by a reference EIA. No significant interference or cross-reactions were observed. Testing of 4,984 archived specimens yielded a sensitivity of 99.2% and a specificity of 99.7%. A prospective multicenter clinical study with 2,954 adult volunteers demonstrated sensitivity and specificity for the Efoora HIV rapid test of 99.8% (95% confidence interval [CI], 99.3 and 99.98%) and 99.0% (95% CI, 98.5 and 99.4%), respectively. Reactive rapid HIV-1 antibody detection was confirmed in 99.6% of those with a known HIV infection (n = 939), 5.2% of those in the high-risk group (n = 1,003), and 0.1% of those in the low-risk group (n = 1,012). For 21 (0.71%) patients, there was discordance between the results of the rapid test and the confirmatory EIA/Western blot tests. We conclude that the Efoora HIV rapid test is a simple, rapid assay for detection of HIV-1 antibodies, with high sensitivity and specificity compared to a standardized

  7. Comparison of Rapid Point-of-Care Tests for Detection of Antibodies to Hepatitis C Virus.

    Science.gov (United States)

    Fisher, Dennis G; Hess, Kristen L; Erlyana, Erlyana; Reynolds, Grace L; Cummins, Catherine A; Alonzo, Todd A

    2015-09-01

    Background.  Hepatitis C is one of the most prevalent blood-borne diseases in the United States. Despite the benefits of early screening, among 3.2 million Americans who are infected with hepatitis C virus (HCV), 50%-70% are unaware of their infection status. Methods.  Data were collected between 2011 and 2014, from 1048 clients who were in the following groups: (1) injection drug users, (2) women at sexual risk, (3) gay and bisexual men, and (4) transgender individuals. The sensitivity and specificity of point-of-care tests included (1) the MedMira rapid human immunodeficiency virus (HIV)/HCV antibody test, (2) MedMira hepatitis B (HBV)/HIV/HCV antibody test, (3) Chembio HCV Screen Assay used with both whole blood and (4) oral specimens, (5) Chembio HIV-HCV Assay also used with both whole blood and (6) oral specimens, (7) Chembio HIV-HCV-Syphilis Assay, and (8) OraSure HCV Rapid Antibody Test used with whole blood. The gold standard for the HCV tests were HCV enzyme immunoassay (EIA) 2.0. Results.  OraSure had the highest sensitivity at 92.7% (95% confidence interval [CI] = 88.8%-96.5%) followed closely by Chembio's 3 blood tests at 92.1% (95% CI = 87.7%-96.4%), 91.5% (95% CI = 87.2%-95.7%), and 92.3% (95% CI = 88.4%-96.2%). The sensitivities of MedMira HIV/HCV and MedMira HIV/HCV/HBV tests were the lowest, at 79.1% (95% CI = 72.6%-85.5%), and 81.5% (95% CI = 75.2%-87.8%), respectively. Specificity for the OraSure was 99.8% (95% CI = 99.4%-100%); specificity for the Chembio blood tests was 99.2% (95% CI = 98.6%-99.9%), 99.4% (95% CI = 98.8%-99.9%), and 99.3% (95% CI = 98.8%-99.9%); and specificity for the MedMira was100% and 100%. False-negative results were associated with HIV and hepatitis B core antibody serostatus. Conclusions.  The OraSure and Chembio blood tests (including those multiplexed with HIV and syphilis) appear to good performance characteristics. This study has identified potential limitations of rapid testing in those testing positive for

  8. Negative results of a rapid antibody test for HIV in a 16-month-old infant with AIDS.

    Science.gov (United States)

    Zhang, Yunzhi; Wang, Jiangrong; Wilson, Gregory J; Tang, Yi-Wei; Lu, Hong-Zhou

    2008-01-01

    In a 16-mo-old infant born to an HIV-infected mother, repeatedly negative results of a HIV rapid antibody test had been reported during the past 6 mo. The infant presented with several HIV-defining illnesses and HIV RT-PCR testing confirmed the presence of HIV infection. There are at least 2 possible explanations for the child's false-negative rapid HIV test results: First, his primary antibody production may have been suppressed by the presence of maternal IgG antibodies. Second, his mother was highly immunosuppressed, so that the low level of maternally derived IgG was only detected by HIV-EIA and Western blot. Our data suggest that the HIV rapid antibody test may not be sufficiently sensitive to detect HIV antibodies in infants aged <18 mo.

  9. Comparison of two commercial rapid in-clinic serological tests for detection of antibodies against Leishmania spp. in dogs.

    Science.gov (United States)

    Athanasiou, Labrini V; Petanides, Theodoros A; Chatzis, Manolis K; Kasabalis, Dimitrios; Apostolidis, Kosmas N; Saridomichelakis, Manolis N

    2014-03-01

    Antibodies against Leishmania spp. are detected in most dogs with clinical signs of leishmaniasis due to Leishmania infantum. Accurate, rapid in-clinic serological tests may permit immediate confirmation of the diagnosis and implementation of therapeutic measures. The aim of the current study was to evaluate the diagnostic accuracy of 2 commercial, rapid in-clinic serological tests for the detection of anti-Leishmania antibodies in sera of dogs, the Snap Canine Leishmania Antibody Test kit (IDEXX Laboratories Inc., Westbrook, Maine) and the ImmunoRun Antibody Detection kit (Biogal Galed Labs, Kibbutz Galed, Israel), using indirect fluorescent antibody test (IFAT) as the reference method. A total of 109 sera collected from 65 seropositive and 44 seronegative dogs were used. The sensitivities of the Snap and ImmunoRun kits were 89.23% (95% confidence interval: 79.05-95.54%) and 86.15% (95% confidence interval: 75.33-93.45%), respectively, and the specificity of both tests was 100%. A good agreement between each of the rapid in-clinic serological tests and IFAT and between the 2 rapid in-clinic serological tests was witnessed. Both rapid in-clinic serological tests showed an adequate diagnostic accuracy and can be used for the fast detection of antibodies against L. infantum in dogs.

  10. Investigation of false positive results with an oral fluid rapid HIV-1/2 antibody test.

    Science.gov (United States)

    Jafa, Krishna; Patel, Pragna; Mackellar, Duncan A; Sullivan, Patrick S; Delaney, Kevin P; Sides, Tracy L; Newman, Alexandra P; Paul, Sindy M; Cadoff, Evan M; Martin, Eugene G; Keenan, Patrick A; Branson, Bernard M

    2007-01-31

    In March 2004, the OraQuick rapid HIV antibody test became the first rapid HIV test approved by the US Food and Drug Administration for use on oral fluid specimens. Test results are available in 20 minutes, and the oral fluid test is non-invasive. From August 2004-June 2005, we investigated a sudden increase in false-positive results occurring in a performance study of OraQuick oral-fluid rapid HIV tests in Minnesota. In a field investigation, we reviewed performance study data on oral-fluid and whole-blood OraQuick rapid HIV test device lots and expiration dates and assessed test performance and interpretation with oral-fluid and whole-blood specimens by operators who reported false-positive results. We used multivariate logistic regression to evaluate client demographic and risk characteristics associated with false-positive results. Next, we conducted an incidence study of false-positive OraQuick rapid HIV tests in nine US cities and tested both oral-fluid and finger-stick whole-blood specimens from clients; reactive tests were confirmed with Western blot. Sixteen (4.1%) false-positive oral-fluid results occurred in the performance study from April 15, 2004 through August 31, 2004 with unexpired devices from six test lots among 388 HIV-uninfected clients (specificity, 95.9%; 95% CI: 93.4-97.6). Three test operators who had reported false-positive results performed and interpreted the test according to package-insert instructions. In multivariate analysis, only older age was significantly associated with false-positive results (adjusted odds ratio = 4.5, 95% CI: 1.2-25.7). In the incidence study, all valid oral-fluid and whole-blood results from 2,268 clients were concordant and no false-positive results occurred (100% specificity). The field investigation did not identify a cause for the increase in false-positive oral-fluid results, and the incidence study detected no false-positive results. The findings suggest this was an isolated cluster; the test's overall

  11. Investigation of false positive results with an oral fluid rapid HIV-1/2 antibody test.

    Directory of Open Access Journals (Sweden)

    Krishna Jafa

    Full Text Available BACKGROUND: In March 2004, the OraQuick rapid HIV antibody test became the first rapid HIV test approved by the US Food and Drug Administration for use on oral fluid specimens. Test results are available in 20 minutes, and the oral fluid test is non-invasive. From August 2004-June 2005, we investigated a sudden increase in false-positive results occurring in a performance study of OraQuick oral-fluid rapid HIV tests in Minnesota. METHODOLOGY/PRINCIPAL FINDINGS: In a field investigation, we reviewed performance study data on oral-fluid and whole-blood OraQuick rapid HIV test device lots and expiration dates and assessed test performance and interpretation with oral-fluid and whole-blood specimens by operators who reported false-positive results. We used multivariate logistic regression to evaluate client demographic and risk characteristics associated with false-positive results. Next, we conducted an incidence study of false-positive OraQuick rapid HIV tests in nine US cities and tested both oral-fluid and finger-stick whole-blood specimens from clients; reactive tests were confirmed with Western blot. Sixteen (4.1% false-positive oral-fluid results occurred in the performance study from April 15, 2004 through August 31, 2004 with unexpired devices from six test lots among 388 HIV-uninfected clients (specificity, 95.9%; 95% CI: 93.4-97.6. Three test operators who had reported false-positive results performed and interpreted the test according to package-insert instructions. In multivariate analysis, only older age was significantly associated with false-positive results (adjusted odds ratio = 4.5, 95% CI: 1.2-25.7. In the incidence study, all valid oral-fluid and whole-blood results from 2,268 clients were concordant and no false-positive results occurred (100% specificity. CONCLUSIONS/SIGNIFICANCE: The field investigation did not identify a cause for the increase in false-positive oral-fluid results, and the incidence study detected no false

  12. The diagnostic sensitivity of dengue rapid test assays is significantly enhanced by using a combined antigen and antibody testing approach.

    Directory of Open Access Journals (Sweden)

    Scott R Fry

    2011-06-01

    Full Text Available BACKGROUND: Serological tests for IgM and IgG are routinely used in clinical laboratories for the rapid diagnosis of dengue and can differentiate between primary and secondary infections. Dengue virus non-structural protein 1 (NS1 has been identified as an early marker for acute dengue, and is typically present between days 1-9 post-onset of illness but following seroconversion it can be difficult to detect in serum. AIMS: To evaluate the performance of a newly developed Panbio® Dengue Early Rapid test for NS1 and determine if it can improve diagnostic sensitivity when used in combination with a commercial IgM/IgG rapid test. METHODOLOGY: The clinical performance of the Dengue Early Rapid was evaluated in a retrospective study in Vietnam with 198 acute laboratory-confirmed positive and 100 negative samples. The performance of the Dengue Early Rapid in combination with the IgM/IgG Rapid test was also evaluated in Malaysia with 263 laboratory-confirmed positive and 30 negative samples. KEY RESULTS: In Vietnam the sensitivity and specificity of the test was 69.2% (95% CI: 62.8% to 75.6% and 96% (95% CI: 92.2% to 99.8 respectively. In Malaysia the performance was similar with 68.9% sensitivity (95% CI: 61.8% to 76.1% and 96.7% specificity (95% CI: 82.8% to 99.9% compared to RT-PCR. Importantly, when the Dengue Early Rapid test was used in combination with the IgM/IgG test the sensitivity increased to 93.0%. When the two tests were compared at each day post-onset of illness there was clear differentiation between the antigen and antibody markers. CONCLUSIONS: This study highlights that using dengue NS1 antigen detection in combination with anti-glycoprotein E IgM and IgG serology can significantly increase the sensitivity of acute dengue diagnosis and extends the possible window of detection to include very early acute samples and enhances the clinical utility of rapid immunochromatographic testing for dengue.

  13. Rapid identification of vibrio-cholerae O1 by coaglutination test using mono-specifis antibody

    Directory of Open Access Journals (Sweden)

    Bazargan SA

    1996-07-01

    Full Text Available In our investigation, rabbit hyper-immune serum to V.cholerae ogawa was absorbed with V.cholerae inaba whole-cells and vice versa. Applying ammonium sulphate precipitation method, mono-specific g globulins were purified and concentrated from the absorbed whole serum. These antibodies were fixed on staphylococcus cowan 1 NCTC-8325 whole-cells, using different chemical fixatives. It was observed that maximum fixation of g globulin to protein-A was achieved by 1-propanol 50% at 3 hours, which revealed through single radial immuno-diffusion techniqe. The rectal swab samples were cultured in an enrichment bile-peptons broth. After 5 hours 37°C while agitations, one drop of each sample was mixed with one drop of vibrio-cholerae bivalent mono-specific coagglutination reagent (VBCR. The results were read after 2 to 3 minutes. Finally though statistical analysis sensitivity and specificity of coagglutination test were calculated to be 95.1% and 99.2% respectively, when compared to positive & negative controls and conventional culture methods. Using VBCR, coagglutination test can be therefore considered as a simple, reliable and rapid method to detect V.cholerae O1 in the stool of patients in endemic area and less equipped laboratories

  14. Minimising invasiveness in diagnostics: developing a rapid urine-based monoclonal antibody dipstick test for malaria.

    Science.gov (United States)

    Markakpo, Uri S; Bosompem, Kwabena M; Dzodzomenyo, Mawuli; Danso-Appiah, Anthony; Essuman, Edward E; Anyan, William K; Suzuki, Mitsuko; Stephens, Judith K; Anim-Baidoo, Isaac; Asmah, Richard H; Ofori, Michael F; Madjitey, Parnor; Danquah, Jonas B; Frempong, Naa Adjeley; Kwofie, Kofi D; Amoa-Bosompem, Michael; Sullivan, David; Fobil, Julius N; Quakyi, Isabella A

    2016-10-01

    To generate monoclonal antibodies (MAbs) for developing a rapid malaria diagnostic urine-based assay (RUBDA), using Plasmodium-infected human urinary antigens. Plasmodium-infected human urinary (PAgHU) and cultured parasite (CPfAg) antigens were used to generate mouse MAbs. The reactivity and accuracy of the MAbs produced were then evaluated using microplate ELISA, SDS-PAGE, Western blotting assay, microscopy and immunochromatographic tests. Ninety-six MAb clones were generated, of which 68.8% reacted to both PAgHU and CPfAg, 31.3% reacted to PAgHU only, and none reacted to CPfAg only. One promising MAb (UCP4W7) reacted in WBA, to both PAgHU and CPfAg, but not to Plasmodium-negative human urine and blood, Schistosoma haematobium and S. mansoni antigens nor measles and poliomyelitis vaccines. MAb UCP4W7 seems promising for diagnosing Plasmodium infection. Urine is a reliable biomarker source for developing non-invasive malaria diagnostic tests. SDS-PAGE and MAb-based WBA appear explorable in assays for detecting different levels of Plasmodium parasitaemia. © 2016 John Wiley & Sons Ltd.

  15. Comparison of a Micro-Neutralization Test with the Rapid Fluorescent Focus Inhibition Test for Measuring Rabies Virus Neutralizing Antibodies

    Directory of Open Access Journals (Sweden)

    Todd G. Smith

    2017-07-01

    Full Text Available The rapid fluorescent focus inhibition test (RFFIT is routinely used in the United States to measure rabies virus neutralizing antibodies (rVNA. RFFIT has a long history of reproducible and reliable results. The test has been modified over the years to use smaller volumes of reagents and samples, but requires a 50 μL minimum volume of test serum. To conduct pathogenesis studies, small laboratory animals such as mice are regularly tested for rVNA, but the minimum volume for a standard RFFIT may be impossible to obtain, particularly in scenarios of repeated sampling. To address this problem, a micro-neutralization test was developed previously. In the current study, the micro-neutralization test was compared to the RFFIT using 129 mouse serum samples from rabies vaccine studies. Using a cut-off value of 0.1 IU/mL, the sensitivity, specificity, and concordance of the micro-neutralization test were 100%, 97.5%, and 98%, respectively. The geometric mean titer of all samples above the cut-off was 2.0 IU/mL using RFFIT and 3.4 IU/mL using the micro-neutralization test, indicating that titers determined using the micro-neutralization test are not equivalent to RFFIT titers. Based on four rVNA-positive hamster serum samples, the intra-assay coefficient of variability was 24% and inter-assay coefficient of variability was 30.4%. These results support continued use of the micro-neutralization test to determine rabies virus neutralizing antibody titers for low-volume serum samples.

  16. Development of immunochromatographic strip test using fluorescent, micellar silica nanosensors for rapid detection of B. abortus antibodies in milk samples.

    Science.gov (United States)

    Vyas, Swati S; Jadhav, Sushma V; Majee, Sharmila B; Shastri, Jayanthi S; Patravale, Vandana B

    2015-08-15

    Presence of bacteria such as Brucella spp. in dairy products is an immense risk to public health. Point of care immunoassays are rapid in that they can quickly screen various samples in a relatively short amount of time, are sensitive, specific and offer a great advantage in accurate and fast diagnosis of infectious diseases. We have fabricated a point of care rapid diagnostic assay that employs fluorescent, micellar silica nanosensors capable of specifically detecting Brucella IgG antibodies in milk samples of afflicted animals. Currently, point of care detection assays are not commercially available for field testing of farm animals using milk samples. The nanosensing allows precise detection of antibodies with low sample volumes (50 μl). We demonstrate recognition of B. abortus antibodies through capture by fluorescent silica nanosensors using spiked and raw milk samples validated by ELISA and PCR. The test results are accurate and repeatable with high sensitivity and specificity, and a short assay time of 10 min for antigenic recognition and do not require any sample processing procedures such as isolation and separation. Additionally, well defined antigenic components and surface biomarkers of various disease causing microbes can be broadly incorporated within the purview of this technology for accurate and rapid detection of suspected bovine pathological conditions, and can largely enable rapid field testing that can be implemented in farms and food industry. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Factors associated with false-positive results from fingerstick OraQuick ADVANCE rapid HIV 1/2 antibody test.

    Science.gov (United States)

    Rifkin, Samara B; Owens, Lauren E; Greenwald, Jeffrey L

    2012-01-01

    Identify factors associated with false-positive rapid HIV antibody tests. This retrospective cohort study with nested case-controls involved patients tested for HIV by Boston Medical Center (BMC) affiliates. Cases had a reactive fingerstick OraQuick ADVANCE rapid HIV 1/2 antibody test and a negative Western blot. Controls had nonreactive rapid tests. We compared the prevalence of HIV risk factors between cases and the total nonreactive population and the prevalence of other clinical factors between cases and controls. Of the 15 094 tests, 14 937 (98.9%) were negative and 11 (0.07%) were false positives (specificity of 99.9%). Cases were more likely to have had an HIV-infected sex partner and to be tested at certain sites compared to true negatives. More cases than controls had O-negative blood type. O-negative blood type and sex with an HIV-infected person may increase false-positive HIV fingerstick results. More targeted studies should examine these risk factors.

  18. Hepatitis B Surface Antibody (HBsAb Screening with Rapid Test among Teenagers in Surabaya

    Directory of Open Access Journals (Sweden)

    Moch Irfan Hadi

    2017-09-01

    Full Text Available Hepatitis was an inflammation or infection of the liver cells and generally caused by the virus, resulting in the liver swelled. Hepatitis B disease is caused by acute or chronic Hepatitis B virus and includes the most dangerous liver disease. World Health Organization (WHO estimates in 2002 that one billion living individuals are infected with Hepatitis B, so more than 200 million people worldwide are infected, and 1-2 million deaths annually are associated with VHB. In 2008 the number of people infected with VHB was 2 billion, and 350 million people continued to be patients with chronic hepatitis B infection. Generally most of Hepatitis B immunization studies that have been conducted in Indonesia only observe the early age group (infant and quite rare for adolescence groups. Those group of teenagers becomes very important subject because they will soon be married and have children in the future. The research aimed to investigated HbsAb-based hepatitis using Rapid test among teenagers. This research was conducted in the Boarding School Health Study Center of Nadhlatul Ulama University Surabaya. Fifty-four teenagers were tested using HbsAb rapid test. The HBsAb rapid test result found 2 teenagers positive to hepatitis.

  19. Platelet antibodies blood test

    Science.gov (United States)

    This blood test shows if you have antibodies against platelets in your blood. Platelets are a part of the blood ... Chernecky CC, Berger BJ. Platelet antibody - blood. In: Chernecky ... caused by platelet destruction, hypersplenism, or hemodilution. ...

  20. Poor sensitivity of rapid tests for the detection of antibodies to the hepatitis B virus: implications for field studies

    Directory of Open Access Journals (Sweden)

    Helena Medina Cruz

    Full Text Available Rapid tests (RTs can be used as an alternative method for the conventional diagnosis of hepatitis B virus (HBV. This study aims to evaluate antibodies to HBsAg (anti-HBs and antibodies to HBeAg (anti-HBe RTs under different Brazilian settings. The following three groups were included: GI: viral hepatitis outpatient services; GII: low resource areas; and GIII: crack users and beauticians. Imuno-rápido anti-HBsAg™ and Imuno-rápido anti-HBeAg™ RTs were evaluated and showed specificities greater than 95% in all groups. The sensitivity values to anti-HBs were 50.38%, 51.05% and 46.73% and the sensitivity values to anti-HBe were 76.99%, 10.34% and 11.76% in the GI, GII and GIII groups, respectively. The assays had a low sensitivity and high specificity, which indicated their use for screening in regions endemic for HBV.

  1. Development and Evaluation of a Rapid Latex Agglutination Test Using a Monoclonal Antibody To Identify Candida dubliniensis Colonies

    Science.gov (United States)

    Marot-Leblond, Agnes; Beucher, Bertrand; David, Sandrine; Nail-Billaud, Sandrine; Robert, Raymond

    2006-01-01

    Cell components of the dimorphic pathogenic fungus Candida dubliniensis were used to prepare monoclonal antibodies (MAbs). One MAb, designated 12F7-F2, was shown by indirect immunofluorescence to be specific for a surface antigen of Candida dubliniensis yeast cells. No reactivity was observed with other fungal genera or with other Candida species, including Candida albicans, that share many phenotypic features with C. dubliniensis. The use of different chemical and physical treatments for cell component extraction suggested that the specific epitope probably resides on a protein moiety absent from C. albicans. However, we failed to identify the target protein by Western blotting, owing to its sensitivity to heat and sodium dodecyl sulfate. MAb 12F7-F2 was further used to develop a commercial latex agglutination test to identify C. dubliniensis colonies (Bichro-dubli Fumouze test; Fumouze Diagnostics). The test was validated on yeast strains previously identified by PCR and on fresh clinical isolates; these included 46 C. dubliniensis isolates, 45 C. albicans isolates, and other yeast species. The test had 100% sensitivity and specificity for C. dubliniensis isolated on Sabouraud dextrose, CHROMagar Candida, and CandiSelect media and 97.8% sensitivity for C. dubliniensis grown on Candida ID medium. The test is rapid (5 min) and easy to use and may be recommended for routine use in clinical microbiology laboratories and for epidemiological investigations. PMID:16390961

  2. Evaluation of a rapid test for HIV antibodies in saliva and blood ...

    African Journals Online (AJOL)

    Saliva specimens can be readily collected from any individual, and there is a reduction in hazard risk. Anti-HIV saliva testing using the test strip methodology is recommended for South Africa, particularly in high-risk situations such as the paediatric and forensic medicine settings. A larger field study obtaining specimens from ...

  3. Development of monoclonal antibodies and immunochromatographic lateral flow device for rapid test of alanine aminotransferase isoenzyme 1.

    Science.gov (United States)

    Hu, Xiaomei; Cheng, Shiliang; Liu, Xinfeng; Li, Jie; Zheng, Wen; Lu, Gang; Zhang, Jun; Zheng, Jian; Zhang, Juan

    2016-03-01

    Alanine aminotransferase (ALT) has been used as a sensitive marker for liver injury in people and in preclinical toxicity studies. But measurement of ALT isoenzymes, ALT1 and ALT2, was reported to be of more diagnostic value. The aim of this study is to develop an ideal pair of anti-ALT1 monoclonal antibodies (MAbs) of high specificity and affinity, and subsequently prepare a Immunochromatographic lateral flow device (LFD) for rapid test of ALT1 in human serums. The complete coding sequence of ALT1 gene (1500 bp) was cloned from human hepatoma G2 cells (HepG2) and inserted into the expression vector pET-32a(+). ALT1 recombinant protein was routinely prepared by E. coli BL21 (DE3) expression and Ni(2+) affinity purification. Balb/c mice were immunized with purified ALT1 and the splenocytes were fused with Sp2/0 myeloma cells. The positive clones, verified by indirect enzyme-linked immunosorbent assay (ELISA) using purified ALT1, were subcloned to single clones by limiting dilution process. A MAb pair was selected from the obtained MAbs according the sandwich ELISA pairing results and then used for lateral flow device (LFD) production. After evaluation of the sensitivity and specificity, the LFD strips were employed to test human serum samples with known ALT activity levels. ALT1 recombinant protein was expectedly prepared by expression and purification. A total of 8 stable clones that produced antibodies specifically recognizing ALT1 protein were developed. After sandwich ELISA pairing, an ideal pair of anti-ALT1 MAbs, designated as BD7 and DG3, were selected and proved to be of high specificity, titer and affinity. Based on the MAb pair, LFD strips specifically for ALT1 rapid test were subsequently prepared. The detection threshold of the LFD strips was 12 U/L. No cross reaction was found. The ALT1 LFD with high sensitivity and specificity was successfully developed. It is valuable for testing ALT1 protein in human sera and can be a beneficial complement for

  4. Failure of a novel, rapid antigen and antibody combination test to detect antigen-positive HIV infection in African adults with early HIV infection.

    Directory of Open Access Journals (Sweden)

    William Kilembe

    Full Text Available BACKGROUND: Acute HIV infection (prior to antibody seroconversion represents a high-risk window for HIV transmission. Development of a test to detect acute infection at the point-of-care is urgent. METHODS: Volunteers enrolled in a prospective study of HIV incidence in four African cities, Kigali in Rwanda and Ndola, Kitwe and Lusaka in Zambia, were tested regularly for HIV by rapid antibody test and p24 antigen ELISA. Five subgroups of samples were also tested by the Determine Ag/Ab Combo test 1 Antigen positive, antibody negative (acute infection; 2 Antigen positive, antibody positive; 3 Antigen negative, antibody positive; 4 Antigen negative, antibody negative; and 5 Antigen false positive, antibody negative (HIV uninfected. A sixth group included serial dilutions from a p24 antigen-positive control sample. Combo test results were reported as antigen positive, antibody positive, or both. RESULTS: Of 34 group 1 samples with VL between 5x105 and >1.5x107 copies/mL (median 3.5x106, 1 (2.9% was detected by the Combo antigen component, 7 (20.6% others were positive by the Combo antibody component. No group 2 samples were antigen positive by the Combo test (0/18. Sensitivity of the Combo antigen test was therefore 1.9% (1/52, 95% CI 0.0, 9.9. One false positive Combo antibody result (1/30, 3.3% was observed in group 4. No false-positive Combo antigen results were observed. The Combo antigen test was positive in group 6 at concentrations of 80 pg/mL, faintly positive at 40 and 20 pg/mL, and negative thereafter. The p24 ELISA antigen test remained positive at 5 pg/mL. CONCLUSIONS: Although the antibody component of the Combo test detected antibodies to HIV earlier than the comparison antibody tests used, less than 2% of the cases of antigen-positive HIV infection were detected by the Combo antigen component. The development of a rapid point-of-care test to diagnose acute HIV infection remains an urgent goal.

  5. Failure of a novel, rapid antigen and antibody combination test to detect antigen-positive HIV infection in African adults with early HIV infection.

    Science.gov (United States)

    Kilembe, William; Keeling, Michelle; Karita, Etienne; Lakhi, Shabir; Chetty, Paramesh; Price, Matt A; Makkan, Heeran; Latka, Mary; Likoti, Morongwe; Ilukui, Kenneth; Hurlston, Mackenzie; Allen, Susan; Stevens, Gwynn; Hunter, Eric

    2012-01-01

    Acute HIV infection (prior to antibody seroconversion) represents a high-risk window for HIV transmission. Development of a test to detect acute infection at the point-of-care is urgent. Volunteers enrolled in a prospective study of HIV incidence in four African cities, Kigali in Rwanda and Ndola, Kitwe and Lusaka in Zambia, were tested regularly for HIV by rapid antibody test and p24 antigen ELISA. Five subgroups of samples were also tested by the Determine Ag/Ab Combo test 1) Antigen positive, antibody negative (acute infection); 2) Antigen positive, antibody positive; 3) Antigen negative, antibody positive; 4) Antigen negative, antibody negative; and 5) Antigen false positive, antibody negative (HIV uninfected). A sixth group included serial dilutions from a p24 antigen-positive control sample. Combo test results were reported as antigen positive, antibody positive, or both. Of 34 group 1 samples with VL between 5x105 and >1.5x107 copies/mL (median 3.5x106), 1 (2.9%) was detected by the Combo antigen component, 7 (20.6%) others were positive by the Combo antibody component. No group 2 samples were antigen positive by the Combo test (0/18). Sensitivity of the Combo antigen test was therefore 1.9% (1/52, 95% CI 0.0, 9.9). One false positive Combo antibody result (1/30, 3.3%) was observed in group 4. No false-positive Combo antigen results were observed. The Combo antigen test was positive in group 6 at concentrations of 80 pg/mL, faintly positive at 40 and 20 pg/mL, and negative thereafter. The p24 ELISA antigen test remained positive at 5 pg/mL. Although the antibody component of the Combo test detected antibodies to HIV earlier than the comparison antibody tests used, less than 2% of the cases of antigen-positive HIV infection were detected by the Combo antigen component. The development of a rapid point-of-care test to diagnose acute HIV infection remains an urgent goal.

  6. Programmatic evaluation of a combined antigen and antibody test for rapid HIV diagnosis in a community and sexual health clinic screening programme.

    Science.gov (United States)

    Taegtmeyer, Miriam; MacPherson, Peter; Jones, Kathy; Hopkins, Mark; Moorcroft, Jay; Lalloo, David G; Chawla, Anu

    2011-01-01

    A substantial proportion of HIV-infected individuals in the UK are unaware of their status and late presentations continue, especially in low prevalence areas. Fourth generation antigen/antibody rapid test kits could facilitate earlier diagnosis of HIV in non-clinical settings but lack data on performance under programmatic conditions. We evaluated the performance of Determine HIV-1/2 Ag/Ab Combo Test (Determine Combo), a rapid test with indicators for both HIV antibodies and p24 antigen, in participants recruited from community outreach and hospital-based sexual health clinics. HIV infection was confirmed using laboratory enzyme-linked immunosorbent assay (EIA), Line Immuno Assay (LIA) and quantitative polymerase chain reaction (PCR). In total, 953 people underwent HIV testing. HIV antibody (Ab) prevalence was 1.8% (17/953). Four false positive rapid tests were identified: two antibody and two p24 antigen (Ag) reactions. Of participants diagnosed as HIV Ab positive, 2/17 (12%) were recent seroconverters based on clinical history and HIV antibody avidity test results. However, none of these were detected by the p24 antigen component of the rapid test kit. There were no other true positive p24 Ag tests. These data lend support to an increasing body of evidence suggesting that 4th generation rapid HIV tests have little additional benefit over 3rd generation HIV kits for routine screening in low prevalence settings and have high rates of false positives. In order to optimally combine community-based case-finding among hard-to-reach groups with reliable and early diagnosis 3rd generation kits should be primarily used with laboratory testing of individuals thought to be at risk of acute HIV infection. A more reliable point of care diagnostic is required for the accurate detection of acute HIV infection under programmatic conditions.

  7. Programmatic evaluation of a combined antigen and antibody test for rapid HIV diagnosis in a community and sexual health clinic screening programme.

    Directory of Open Access Journals (Sweden)

    Miriam Taegtmeyer

    Full Text Available BACKGROUND: A substantial proportion of HIV-infected individuals in the UK are unaware of their status and late presentations continue, especially in low prevalence areas. Fourth generation antigen/antibody rapid test kits could facilitate earlier diagnosis of HIV in non-clinical settings but lack data on performance under programmatic conditions. METHODS AND FINDINGS: We evaluated the performance of Determine HIV-1/2 Ag/Ab Combo Test (Determine Combo, a rapid test with indicators for both HIV antibodies and p24 antigen, in participants recruited from community outreach and hospital-based sexual health clinics. HIV infection was confirmed using laboratory enzyme-linked immunosorbent assay (EIA, Line Immuno Assay (LIA and quantitative polymerase chain reaction (PCR. In total, 953 people underwent HIV testing. HIV antibody (Ab prevalence was 1.8% (17/953. Four false positive rapid tests were identified: two antibody and two p24 antigen (Ag reactions. Of participants diagnosed as HIV Ab positive, 2/17 (12% were recent seroconverters based on clinical history and HIV antibody avidity test results. However, none of these were detected by the p24 antigen component of the rapid test kit. There were no other true positive p24 Ag tests. CONCLUSION: These data lend support to an increasing body of evidence suggesting that 4th generation rapid HIV tests have little additional benefit over 3rd generation HIV kits for routine screening in low prevalence settings and have high rates of false positives. In order to optimally combine community-based case-finding among hard-to-reach groups with reliable and early diagnosis 3rd generation kits should be primarily used with laboratory testing of individuals thought to be at risk of acute HIV infection. A more reliable point of care diagnostic is required for the accurate detection of acute HIV infection under programmatic conditions.

  8. ANA (Antinuclear Antibody Test)

    Science.gov (United States)

    ... Testing Leptin Levetiracetam Lipase Lipid Profile Lipoprotein (a) Lithium Liver Panel Lp-PLA2 Lupus Anticoagulant Testing Luteinizing ... Scleroderma Elsewhere On The Web Lupus Foundation of America American College of Rheumatology: Antinuclear Antibodies (ANA) American ...

  9. Antibody Blood Tests

    Science.gov (United States)

    Antibody Blood Tests Researchers have discovered that people with celiac disease who eat gluten have higher than normal levels of ... do I do if I have a negative blood test (or panel) but I’m still having symptoms? ...

  10. Evaluation of the HerpeSelect Express rapid test in the detection of herpes simplex virus type 2 antibodies in patients with genital ulcer disease.

    Science.gov (United States)

    Al-Shobaili, Hani; Hassanein, Khaled M; Mostafa, Marwa Salah; Al Duways, Ali Saleh

    2015-01-01

    A rapid point-of-care test with high sensitivity and specificity is required in order to fulfill the need for early detection and screening of Herpes simplex virus type 2 (HSV-2) infection among patients with genital ulcer disease (GUD), for better management and control of virus transmission. The goal of this study is to evaluate the performance of the commercially available HerpeSelect Express rapid test in comparison with three ELISA assays: HerpeSelect ELISA, Kalon HSV-2 glycoprotein G2 assay, and monoclonal antibody blocking enzyme immunoassay, which was used as the gold standard for the detection of HSV-2 antibodies. This study showed high sensitivity (ranging from 82.6 to 100%) and specificity (100%) of the HerpeSelect Express rapid test when compared to the three ELISA assays. The agreement between the HerpeSelect Express rapid test with the three ELISAs ranged from 93.3 to 100%. The HerpeSelect Express rapid test has adequate sensitivity and specificity for confirming HSV-2 infection in patients with GUD, indicating its suitability for epidemiological studies. © 2014 Wiley Periodicals, Inc.

  11. Comparison of biotinylated monoclonal and polyclonal antibodies in an evaluation of a direct rapid immunohistochemical test for the routine diagnosis of rabies in southern Africa.

    Science.gov (United States)

    Coetzer, Andre; Sabeta, Claude T; Markotter, Wanda; Rupprecht, Charles E; Nel, Louis H

    2014-09-01

    The major etiological agent of rabies, rabies virus (RABV), accounts for tens of thousands of human deaths per annum. The majority of these deaths are associated with rabies cycles in dogs in resource-limited countries of Africa and Asia. Although routine rabies diagnosis plays an integral role in disease surveillance and management, the application of the currently recommended direct fluorescent antibody (DFA) test in countries on the African and Asian continents remains quite limited. A novel diagnostic assay, the direct rapid immunohistochemical test (dRIT), has been reported to have a diagnostic sensitivity and specificity equal to that of the DFA test while offering advantages in cost, time and interpretation. Prior studies used the dRIT utilized monoclonal antibody (MAb) cocktails. The objective of this study was to test the hypothesis that a biotinylated polyclonal antibody (PAb) preparation, applied in the dRIT protocol, would yield equal or improved results compared to the use of dRIT with MAbs. We also wanted to compare the PAb dRIT with the DFA test, utilizing the same PAb preparation with a fluorescent label. The PAb dRIT had a diagnostic sensitivity and specificity of 100%, which was shown to be marginally higher than the diagnostic efficacy observed for the PAb DFA test. The classical dRIT, relying on two-biotinylated MAbs, was applied to the same panel of samples and a reduced diagnostic sensitivity (83.50% and 90.78% respectively) was observed. Antigenic typing of the false negative samples indicated all of these to be mongoose RABV variants. Our results provided evidence that a dRIT with alternative antibody preparations, conjugated to a biotin moiety, has a diagnostic efficacy equal to that of a DFA relying on the same antibody and that the antibody preparation should be optimized for virus variants specific to the geographical area of focus.

  12. Comparison of biotinylated monoclonal and polyclonal antibodies in an evaluation of a direct rapid immunohistochemical test for the routine diagnosis of rabies in southern Africa.

    Directory of Open Access Journals (Sweden)

    Andre Coetzer

    2014-09-01

    Full Text Available The major etiological agent of rabies, rabies virus (RABV, accounts for tens of thousands of human deaths per annum. The majority of these deaths are associated with rabies cycles in dogs in resource-limited countries of Africa and Asia. Although routine rabies diagnosis plays an integral role in disease surveillance and management, the application of the currently recommended direct fluorescent antibody (DFA test in countries on the African and Asian continents remains quite limited. A novel diagnostic assay, the direct rapid immunohistochemical test (dRIT, has been reported to have a diagnostic sensitivity and specificity equal to that of the DFA test while offering advantages in cost, time and interpretation. Prior studies used the dRIT utilized monoclonal antibody (MAb cocktails. The objective of this study was to test the hypothesis that a biotinylated polyclonal antibody (PAb preparation, applied in the dRIT protocol, would yield equal or improved results compared to the use of dRIT with MAbs. We also wanted to compare the PAb dRIT with the DFA test, utilizing the same PAb preparation with a fluorescent label. The PAb dRIT had a diagnostic sensitivity and specificity of 100%, which was shown to be marginally higher than the diagnostic efficacy observed for the PAb DFA test. The classical dRIT, relying on two-biotinylated MAbs, was applied to the same panel of samples and a reduced diagnostic sensitivity (83.50% and 90.78% respectively was observed. Antigenic typing of the false negative samples indicated all of these to be mongoose RABV variants. Our results provided evidence that a dRIT with alternative antibody preparations, conjugated to a biotin moiety, has a diagnostic efficacy equal to that of a DFA relying on the same antibody and that the antibody preparation should be optimized for virus variants specific to the geographical area of focus.

  13. Comparison of two dengue NS1 rapid tests for sensitivity, specificity and relationship to viraemia and antibody responses

    Directory of Open Access Journals (Sweden)

    Farrar Jeremy

    2010-05-01

    Full Text Available Abstract Background Dengue is a major public health problem in tropical and subtropical countries. Rapid and easy diagnosis of dengue can assist patient triage and care-management. The detection of DENV NS1 on rapid lateral flow tests offers a fast route to a presumptive dengue diagnosis but careful evaluations are urgently needed as more and more people use them. Methods The sensitivity and specificity of the Bio-Rad NS1 Ag Strip and SD Dengue Duo (NS1/IgM/IgG lateral flow rapid tests were evaluated in a panel of plasma samples from 245 Vietnamese patients with RT-PCR confirmed dengue and 47 with other febrile illnesses. Results The NS1 rapid tests had similar diagnostic sensitivities (respectively 61.6% and 62.4% in confirmed dengue cases but were 100% specific. When IgM/IgG results from the SD Dengue Duo were included in the test interpretation, the sensitivity improved significantly from 62.4% with NS1 alone to 75.5% when NS1 and/or IgM was positive and 83.7% when NS1 and/or IgM and/or IgG was positive. Both NS1 assays were significantly more sensitive for primary than secondary dengue. NS1 positivity was associated with the underlying viraemia as NS1-positive samples had a significantly higher viraemia than NS1-negative samples. Conclusions These data suggest that the NS1 test component of these assays are highly specific and have similar levels of sensitivity. The IgM parameter in the SD Duo test improved overall test sensitivity without compromising specificity. The SD Dengue Duo lateral flow rapid test deserves further prospective evaluation in dengue endemic settings.

  14. Comparison of a rapid immunoassay for antibodies to the C6 antigen with conventional tests for antibodies to Borrelia burgdorferi in dogs in Europe.

    Science.gov (United States)

    Gerber, B; Haug, K; Eichenberger, S; Reusch, C E; Wittenbrink, M M

    2009-11-14

    A commercial immunoassay for antibodies to the C6 antigen of Borrelia burgdorferi was evaluated against an IgG in-house ELISA in combination with a Western blot assay to examine 104 samples of serum from 53 healthy Bernese mountain dogs, which were suspected to have a breed predisposition to Lyme borreliosis, and 55 samples from 30 healthy large-breed longhair dogs. The two test methods correlated in 125 (79 per cent) of the samples with an agreement of kappa=0.571 (Pdogs (k=0.681) than with the samples from the control dogs (k=0.347).

  15. Anti-insulin antibody test

    Science.gov (United States)

    Insulin antibodies - serum; Insulin Ab test; Insulin resistance - insulin antibodies; Diabetes - insulin antibodies ... You appear to have an allergic response to insulin Insulin no longer seems to control your diabetes

  16. Antiparietal cell antibody test

    Science.gov (United States)

    APCA; Anti-gastric parietal cell antibody; Atrophic gastritis - anti-gastric parietal cell antibody; Gastric ulcer - anti-gastric parietal cell antibody; Pernicious anemia - anti-gastric parietal cell antibody; ...

  17. Metal Affinity-Enabled Capture and Release Antibody Reagents Generate a Multiplex Biomarker Enrichment System that Improves Detection Limits of Rapid Diagnostic Tests.

    Science.gov (United States)

    Bauer, Westley S; Gulka, Christopher P; Silva-Baucage, Lidalee; Adams, Nicholas M; Haselton, Frederick R; Wright, David W

    2017-10-03

    Multi-antigen rapid diagnostic tests (RDTs) are highly informative, simple, mobile, and inexpensive, making them valuable point-of-care (POC) diagnostic tools. However, these RDTs suffer from several technical limitations-the most significant being the failure to detect low levels of infection. To overcome this, we have developed a magnetic bead-based multiplex biomarker enrichment strategy that combines metal affinity and immunospecific capture to purify and enrich multiple target biomarkers. Modifying antibodies to contain histidine-rich peptides enables reversible loading onto immobilized metal affinity magnetic beads, generating a novel class of antibodies coined "Capture and Release" (CaR) antibody reagents. This approach extends the specificity of immunocapture to metal affinity magnetic beads while also maintaining a common trigger for releasing multiple biomarkers. Multiplex biomarker enrichment is accomplished by adding magnetic beads equipped with CaR antibody reagents to a large sample volume to capture biomarkers of interest. Once captured, these biomarkers are magnetically purified, concentrated, and released into a RDT-compatible volume. This system was tailored to enhance a popular dual-antigen lateral flow malaria RDT that targets Plasmodium falciparum histidine-rich protein-II (HRPII) and Plasmodium lactate dehydrogenase (pLDH). A suite of pLDH CaR antibody reagents were synthesized, characterized, and the optimal CaR antibody reagent was loaded onto magnetic beads to make a multiplex magnetic capture bead that simultaneously enriches pLDH and HRPII from Plasmodium falciparum parasitized blood samples. This system achieves a 17.5-fold improvement in the dual positive HRPII/pan-pLDH detection limits enabling visual detection of both antigens at levels correlating to 5 p/μL. This front-end sample processing system serves as an efficient strategy to improve the sensitivity of RDTs without the need for modifications or remanufacturing.

  18. Validation of the rapid fluorescent focus inhibition test for rabies virus-neutralizing antibodies in clinical samples

    NARCIS (Netherlands)

    Kostense, Stefan; Moore, Susan; Companjen, Arjen; Bakker, Alexander B. H.; Marissen, Wilfred E.; von Eyben, Rie; Weverling, Gerrit Jan; Hanlon, Cathleen; Goudsmit, Jaap

    2012-01-01

    Monoclonal antibodies are successful biologics in treating a variety of diseases, including the prevention or treatment of viral infections. CL184 is a 1:1 combination of two human monoclonal IgG1 antibodies (CR57 and CR4098) against rabies virus, produced in the PER.C6 human cell line. The two

  19. Development of a rapid agglutination latex test for diagnosis of enteropathogenic and enterohemorrhagic Escherichia coli infection in developing world: defining the biomarker, antibody and method.

    Directory of Open Access Journals (Sweden)

    Letícia B Rocha

    2014-09-01

    Full Text Available Enteropathogenic and enterohemorrhagic Escherichia coli (EPEC/EHEC are human intestinal pathogens responsible for diarrhea in both developing and industrialized countries. In research laboratories, EPEC and EHEC are defined on the basis of their pathogenic features; nevertheless, their identification in routine laboratories is expensive and laborious. Therefore, the aim of the present work was to develop a rapid and simple assay for EPEC/EHEC detection. Accordingly, the EPEC/EHEC-secreted proteins EspA and EspB were chosen as target antigens.First, we investigated the ideal conditions for EspA/EspB production/secretion by ELISA in a collection of EPEC/EHEC strains after cultivating bacterial isolates in Dulbecco's modified Eagle's medium (DMEM or DMEM containing 1% tryptone or HEp-2 cells-preconditioned DMEM, employing either anti-EspA/anti-EspB polyclonal or monoclonal antibodies developed and characterized herein. Subsequently, a rapid agglutination latex test (RALT was developed and tested with the same collection of bacterial isolates.EspB was defined as a biomarker and its corresponding monoclonal antibody as the tool for EPEC/EHEC diagnosis; the production of EspB was better in DMEM medium. RALT assay has the sensitivity and specificity required for high-impact diagnosis of neglected diseases in the developing world.RALT assay described herein can be considered an alternative assay for diarrhea diagnosis in low-income countries since it achieved 97% sensitivity, 98% specificity and 97% efficiency.

  20. Evaluation of the accuracy and ease of use of a rapid HIV-1 Antibody Test performed by untrained operators at the point of care.

    Science.gov (United States)

    Galli, Richard A; Green, Kevin F; La Marca, Anthony; Waldman, Lawrence F; Powers, Ronald E; Daly, Amelia C; Shackleton, Christopher R

    2013-12-01

    For broader utilization of rapid HIV antibody assays in point-of-care (POC) settings, methods should be simple enough to be performed with accuracy by untrained test providers, using only the test manufacturer's written instructions. To demonstrate that the INSTI HIV-1 Antibody Test is simple and accurate enough to be successfully run by untrained operators in a POC setting. A prospective study was conducted to compare the results of the FDA-cleared, INSTI HIV-1 Antibody Test (INSTI, bioLytical Laboratories Inc., Richmond, BC, Canada) used by untrained operators on finger-stick whole blood to results obtained by trained laboratory professionals using FDA-cleared comparator methods (CM) on matching venous blood. A total of 1388 subjects were recruited into the study in three diverse US POC sites. One central laboratory was used for CM testing. Untrained operators and experienced laboratory professionals also conducted a study on prepared plasma specimens to compare limit of detection (LoD) abilities. Of the 517 HIV positive subjects (34 new positives and 483 known positives) the concordance between INSTI performed by untrained operators and CM performed by trained laboratory professionals was 100% (95% CI=99.3-100%). Concordance for HIV negative results (n=871) was 99.8% (95% CI=99.2-99.9%). There were no significant differences in INSTI limit of detection between untrained operators and laboratory professionals. Untrained operators with no laboratory background were able to perform and interpret the results of INSTI on finger-stick blood and LoD specimens with a high degree of accuracy by following only the manufacturer's written instructions. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. Comparative evaluation of a rapid diagnostic test, an antibody ELISA, and a pLDH ELISA in detecting asymptomatic malaria parasitaemia in blood donors in Buea, Cameroon.

    Science.gov (United States)

    Kwenti, Tebit Emmanuel; Njunda, Longdoh Anna; Tsamul, Beltine; Nsagha, Shey Dickson; Assob, Nguedia Jules-Clement; Tufon, Kukwah Anthony; Meriki, Dilonga Henry; Orock, Enow George

    2017-08-01

    In malaria endemic areas, infected blood donors serve as a source of infection to blood recipients, which may adversely affect their prognosis. This necessitates the proper screening of blood to be used for transfusion in these areas. The purpose of this study was to determine the prevalence of malaria parasitaemia in blood donors in Buea, Cameroon, and to evaluate the performance of a rapid diagnostic test (RDT), a malaria antibody enzyme-linked immunosorbent assay (ELISA), and a Plasmodium lactate dehydrogenase (pLDH) ELISA in the detection of asymptomatic malaria parasitaemia in the target population. In a prospective study conducted between September 2015 and June 2016, 1 240 potential blood donors were enrolled. The donors were screened for malaria parasites using Giemsa microscopy (GM) and a RDT. A sub-sample of 184 samples, comprising 88 positive and 96 negative samples, were selected for the evaluation of the pLDH ELISA and the antibody ELISA. The chi-square test and correlation analysis were performed as part of the statistical analyses. The statistical significance cut-off was set at P malaria parasitaemia in this study was found to be 8.1% (95% CI: 6.6 - 9.7). The prevalence was not observed to be dependent on the age or sex of the participants. The RDT had a sensitivity (88.0%), specificity (99.1%), and negative predictive value (99.0%) higher than the ELISAs. The performance of the pLDH ELISA, which demonstrated the highest positive predictive value (91.6%), was generally comparable to the RDT. The sensitivity was lowest with the antibody ELISA (69.9%), which also demonstrated the highest false positive and false negative rates. The detection threshold for the pLDH (three parasites/μl) was lower compared to the RDT (50 - 60 parasites/μl). Non-significant positive correlations were observed between the parasite density and the pLDH titers and malaria antibody titers. Overall, the RDT and the pLDH ELISA demonstrated a perfectly correlated agreement

  2. Rapid Strep Test

    Science.gov (United States)

    ... worse than normal. Your first thoughts turn to strep throat. A rapid strep test in your doctor’s office ... your suspicions.Viruses cause most sore throats. However, strep throat is an infection caused by the Group A ...

  3. Utility of feline coronavirus antibody tests.

    Science.gov (United States)

    Addie, Diane D; le Poder, Sophie; Burr, Paul; Decaro, Nicola; Graham, Elizabeth; Hofmann-Lehmann, Regina; Jarrett, Oswald; McDonald, Michael; Meli, Marina L

    2015-02-01

    Eight different tests for antibodies to feline coronavirus (FCoV) were evaluated for attributes that are important in situations in veterinary practice. We compared four indirect immunofluorescent antibody tests (IFAT), one enzyme-linked immunosorbent assay (ELISA) (FCoV Immunocomb; Biogal) and three rapid immunochromatographic (RIM) tests against a panel of samples designated by consensus as positive or negative. Specificity was 100% for all but the two IFATs based on transmissible gastroenteritis virus (TGEV), at 83.3% and 97.5%. The IFAT and ELISA tests were best for obtaining an antibody titre and for working in the presence of virus. The RIM tests were the best for obtaining a result quickly (10-15 mins); of these, the Speed F-Corona was the most sensitive, at 92.4%, followed by FASTest feline infectious peritonitis (FIP; 84.6%) and Anigen Rapid FCoV antibody test (64.1%). Sensitivity was 100% for the ELISA, one FCoV IFAT and one TGEV IFAT; and 98.2% for a second TGEV IFA and 96.1% for a second FCoV IFAT. All tests worked with effusions, even when only blood products were stipulated in the instruction manual. The ELISA and Anigen RIM tests were best for small quantities of sample. The most appropriate FCoV antibody test to use depends on the reason for testing: in excluding a diagnosis of FIP, sensitivity, specificity, small sample quantity, rapidity and ability to work in the presence of virus all matter. For FCoV screening, speed and sensitivity are important, and for FCoV elimination antibody titre is essential. © ISFM and AAFP 2014.

  4. Rapid HIV testing using Determine™ HIV 1/2 antibody tests: is there a difference between the visual appearance of true- and false-positive tests?

    Science.gov (United States)

    Sacks, R; Omodele-Lucien, A; Whitbread, N; Muir, D; Smith, A

    2012-09-01

    HIV point-of-care tests (POCTs) give occasional false positive results, causing unnecessary patient anxiety. We aimed to elicit whether false- and true-positive POCTs differed visually. Seventeen false- and 17 true-positive serum samples were randomized into pairs, comprising one false- and one true-positive sample. Two independent readers identified each POCT as negative or positive and compared line strength between pairs. Six further readers graded line strength, 0-5, from POCT photographs. All true-positive samples were identified positive and 8/17 false-positive samples negative, on repeat testing of stored sera. Eight out of the 9 remaining false-positive tests were described as having weaker pigment uptake than their paired true-positive POCT. Mean grade of line strength was 4.2 in true- and 0.9 in false-positive samples, on photographic evaluation. These results suggest false-positive POCTs may differ visually from true-positive POCTs. If larger studies confirm these findings, we may be able to alleviate anxiety in low risk patients with faintly positive POCTs awaiting their confirmatory laboratory result, where the possibility of a false-positive result could be emphasized.

  5. Rapid detection of anti-Vaccinia virus neutralizing antibodies

    Directory of Open Access Journals (Sweden)

    Lichtfuss Gregor F

    2011-03-01

    Full Text Available Abstract Increasing infections with Monkeypox and Cowpox viruses pose a continuous and growing threat to human health. The standard method for detecting poxvirus neutralizing antibodies is the plaque-reduction neutralization test that is specific but also time-consuming and laborious. Therefore, a rapid and reliable method was developed to determine neutralizing antibody titers within twelve hours. The new assay measures viral mRNA transcription as a marker for actively replicating virus after incomplete neutralization using real-time PCR.

  6. Rapid prototype and test

    Energy Technology Data Exchange (ETDEWEB)

    Gregory, D.L.; Hansche, B.D.

    1996-06-01

    In order to support advanced manufacturing, Sandia has acquired the capability to produce plastic prototypes using stereolithography. Currently, these prototypes are used mainly to verify part geometry and ``fit and form`` checks. This project investigates methods for rapidly testing these plastic prototypes, and inferring from prototype test data actual metal part performance and behavior. Performances examined include static load/stress response, and structural dynamic (modal) and vibration behavior. The integration of advanced non-contacting measurement techniques including scanning laser velocimetry, laser holography, and thermoelasticity into testing of these prototypes is described. Photoelastic properties of the epoxy prototypes to reveal full field stress/strain fields are also explored.

  7. Evaluation of the proficiency of trained non-laboratory health staffs and laboratory technicians using a rapid and simple HIV antibody test.

    Science.gov (United States)

    Kanal, Koum; Chou, Thai Leang; Sovann, Ly; Morikawa, Yasuo; Mukoyama, Yumi; Kakimoto, Kazuhiro

    2005-05-20

    In Cambodia, nearly half of pregnant women attend antenatal care (ANC), which is an entry point of services for prevention of mother-to-child transmission of HIV (PMTCT). However, most of ANC services are provided in health centres or fields, where laboratory services by technicians are not available. In this study, those voluntary confidential counselling and testing (VCCT) counsellors involved in PMTCT were trained by experienced laboratory technicians in our centre on HIV testing using Determine (Abbot Laboratories) HIV1/2 test kits through a half-day training course, which consisted of use of a pipette, how to process whole blood samples, and how to read test result. The trained counsellors were midwives working for ANC and delivery ward in our centre without any experience on laboratory works. The objective of this study was to assess the feasibility of the training by evaluating the proficiency of the trained non-laboratory staffs. The trained counsellors withdrew blood sample after pre-test counselling following ANC, and performed the rapid test. Laboratory technicians routinely did the same test and returned reports of the test results to counsellors. Reports by the counsellors and the laboratory technicians were compared, and discordant reports in two groups were re-tested with the same rapid test kit using the same blood sample. Cause of discordance was detected in discussion with both groups. Of 563 blood samples tested by six trained VCCT counsellors and three laboratory technicians, 11 samples (2.0%) were reported positive in each group, however four discordant reports (0.7%) between the groups were observed, in which two positive reports and two negative reports by the counsellors were negative and positive by the laboratory technicians, respectively. Further investigation confirmed that all the reports by the counsellors were correct, and that human error in writing reports in the laboratory was a cause of these discordant reports. These findings

  8. Evaluation of the proficiency of trained non-laboratory health staffs and laboratory technicians using a rapid and simple HIV antibody test

    Directory of Open Access Journals (Sweden)

    Mukoyama Yumi

    2005-05-01

    Full Text Available Abstract In Cambodia, nearly half of pregnant women attend antenatal care (ANC, which is an entry point of services for prevention of mother-to-child transmission of HIV (PMTCT. However, most of ANC services are provided in health centres or fields, where laboratory services by technicians are not available. In this study, those voluntary confidential counselling and testing (VCCT counsellors involved in PMTCT were trained by experienced laboratory technicians in our centre on HIV testing using Determine (Abbot Laboratories HIV1/2 test kits through a half-day training course, which consisted of use of a pipette, how to process whole blood samples, and how to read test result. The trained counsellors were midwives working for ANC and delivery ward in our centre without any experience on laboratory works. The objective of this study was to assess the feasibility of the training by evaluating the proficiency of the trained non-laboratory staffs. The trained counsellors withdrew blood sample after pre-test counselling following ANC, and performed the rapid test. Laboratory technicians routinely did the same test and returned reports of the test results to counsellors. Reports by the counsellors and the laboratory technicians were compared, and discordant reports in two groups were re-tested with the same rapid test kit using the same blood sample. Cause of discordance was detected in discussion with both groups. Of 563 blood samples tested by six trained VCCT counsellors and three laboratory technicians, 11 samples (2.0% were reported positive in each group, however four discordant reports (0.7% between the groups were observed, in which two positive reports and two negative reports by the counsellors were negative and positive by the laboratory technicians, respectively. Further investigation confirmed that all the reports by the counsellors were correct, and that human error in writing reports in the laboratory was a cause of these discordant

  9. The development of a prototype of a “rapid test” for detection of equine antibodies against tetanus

    OpenAIRE

    Stelzmann, Mareike

    2011-01-01

    the following dissertation, the prototype of a “rapid test” for detection of equine antibodies against tetanus is developed. This test makes it possible to detect antibodies against tetanus in equine serum within one hour. Moreover the prototype allows making a statement about the antibody titer. The standard values of the OIE (WORLD ORGANISATION FOR ANIMAL HEALTH, 2009) to validate in vitro-diagnostical tests for veterinary medicine were followed. The rapid test achieves results comparabl...

  10. Diagnostic accuracy of NS1 ELISA and lateral flow rapid tests for dengue sensitivity, specificity and relationship to viraemia and antibody responses.

    Directory of Open Access Journals (Sweden)

    Vu Ty Hang

    Full Text Available Dengue is a public health problem in many countries. Rapid diagnosis of dengue can assist patient triage and management. Detection of the dengue viral protein, NS1, represents a new approach to dengue diagnosis.The sensitivity and specificity of the Platelia NS1 ELISA assay and an NS1 lateral flow rapid test (LFRT were compared against a gold standard reference diagnostic algorithm in 138 Vietnamese children and adults. Overall, the Platelia NS1 ELISA was modestly more sensitive (82% than the NS1 LFRT (72% in confirmed dengue cases. Both ELISA and LFRT assays were more sensitive for primary than secondary dengue, and for specimens collected within 3 days of illness onset relative to later time points. The presence of measurable DENV-reactive IgG and to a lesser extent IgM in the test sample was associated with a significantly lower rate of NS1 detection in both assays. NS1 positivity was associated with the underlying viraemia, as NS1-positive samples had a significantly higher viraemia than NS1-negative samples matched for duration of illness. The Platelia and NS1 LFRT were 100% specific, being negative in all febrile patients without evidence of recent dengue, as well as in patients with enteric fever, malaria, Japanese encephalitis and leptospirosis.Collectively, these data suggest NS1 assays deserve inclusion in the diagnostic evaluation of dengue patients, but with due consideration for the limitations in patients who present late in their illness or have a concomitant humoral immune response.

  11. Evaluation of Gamma Interferon and Antibody Tuberculosis Tests in Alpacas

    Science.gov (United States)

    Holder, Tom; Clifford, Derek; Dexter, Ian; Brewer, Jacky; Smith, Noel; Waring, Laura; Crawshaw, Tim; Gillgan, Steve; Lyashchenko, Konstantin; Lawrence, John; Clarke, John; de la Rua-Domenech, Ricardo; Vordermeier, Martin

    2012-01-01

    We describe the performance of cell-based and antibody blood tests for the antemortem diagnosis of tuberculosis (TB) in South American camelids (SAC). The sensitivity and specificity of the gamma interferon (IFN-γ) release assay, two lateral flow rapid antibody tests (Stat-Pak and Dual Path Platform [DPP]), and two enzyme-linked immunosorbent assay (ELISA)-based antibody tests (Idexx and Enferplex) were determined using diseased alpacas from Mycobacterium bovis culture-confirmed breakdown herds and TB-free alpacas from geographical areas with no history of bovine TB, respectively. Our results show that while the sensitivities of the IFN-γ and antibody tests were similar (range of 57.7% to 66.7%), the specificity of the IFN-γ test (89.1%) was lower than those of any of the antibody tests (range of 96.4% to 97.4%). This lower specificity of the IFN-γ test was at least in part due to undisclosed Mycobacterium microti infection in the TB-free cohort, which stimulates a positive purified protein derivative (PPD) response. The sensitivity of infection detection could be increased by combining two antibody tests, but even the use of all four antibody tests failed to detect all diseased alpacas. These antibody-negative alpacas were IFN-γ positive. We found that the maximum sensitivity could be achieved only by the combination of the IFN-γ test with two antibody tests in a “test package,” although this resulted in decreased specificity. The data from this evaluation of tests with defined sensitivity and specificity provide potential options for antemortem screening of SAC for TB in herd breakdown situations and could also find application in movement testing and tracing investigations. PMID:22914362

  12. rapid assessment of polio virus antibodies prevalence amongst ...

    African Journals Online (AJOL)

    northern Nigeria. There is paucity of information as it relates to polio antibody prevalence amongst children in the state. Periodic serologic assessment is needed to determine the quality and effectiveness of routine vaccination campaigns carried in the state to rapidly build immunity against poliovirus. Children were.

  13. Epstein-Barr Virus Antibodies Test

    Science.gov (United States)

    ... Links Patient Resources For Health Professionals Subscribe Search Epstein-Barr Virus (EBV) Antibody Tests Send Us Your Feedback ... Antigen D, EA-D IgG Ab Formal Name Epstein-Barr Virus Antibodies This article was last reviewed on ...

  14. Usefulness in clinical practice of a point-of-care rapid test for simultaneous detection of nontreponemal and Treponema pallidum-specific antibodies in patients suffering from documented syphilis.

    Science.gov (United States)

    Guinard, Jérôme; Prazuck, Thierry; Péré, Hélène; Poirier, Claire; LeGoff, Jérôme; Boedec, Erwan; Guigon, Aurélie; Day, Nesrine; Bélec, Laurent

    2013-12-01

    The usefulness of a point-of-care immunochromatographic dual test for the simultaneous detection of both nontreponemal and Treponema pallidum-specific antibodies (Chembio Diagnostics Systems Inc., Medford, NY, USA) was assessed in various situations related to syphilis, by reference to conventional syphilis serology. Thawed sera were obtained from 100 adults including 36 primary syphilis, 6 secondary syphilis, 6 re-infection, 9 recently-treated syphilis, and 43 old syphilis. Doubtful reactivities for the treponemal line were considered positive; doubtful reactivities for the nontreponemal line were considered positive only when the treponemal line was present. The sensitivity, the specificity, and its concordance to gold standard serology of treponemal line were high, around 90%. The sensitivity of nontreponemal line was 96.3%, its specificity 76.7%, and its concordance 83.4%. In conclusion, the dual rapid test from Chembio Diagnostics Systems Inc. is useful for rapid point-of-care diagnosis in the various situations encountered with patients suffering from syphilis.

  15. 21 CFR 866.3290 - Gonococcal antibody test (GAT).

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Gonococcal antibody test (GAT). 866.3290 Section... antibody test (GAT). (a) Identification. A gonococcal antibody test (GAT) is an in vitro device that..., indirect fluorescent antibody, or radioimmunoassay, antibodies to Neisseria gonorrhoeae in sera of...

  16. [Rapid diagnostic test for malaria].

    Science.gov (United States)

    Houzé, S

    2017-02-01

    The rapid diagnostic tests (RDTs) whose main interest lies in their implementation without special equipment by unskilled personnel have grown significantly over the past fifteen years to diagnose malaria. They rely on the detection of specific Plasmodium proteins, PfHRP2, pLDH and aldolase. If the detection of PfHRP2 has very good sensitivity for the diagnosis of Plasmodium falciparum malaria, the detection of pLDH or aldolase is less efficient for other species, leaving its place to the reference microscopic diagnosis. RDT could not generally be used to monitor therapeutic efficacy because they can remain positive after clinical and parasitological cure. Furthermore, the development of the use of these tests has highlighted the need for quality assurance programs to monitor their production as their use.

  17. Evaluation of accuracy of OraQuick ® rapid test in detecting HIV ...

    African Journals Online (AJOL)

    Objective: The accuracy of OraQuick® rapid test in detecting HIV 1 & 2 antibodies in saliva is evaluated against the blood EIA benchmark tests with confirmatory testing, against which OraQuick® accuracy is determined. Method: Paired samples of saliva and blood from 281 Nigerians were tested for HIV antibodies, and ...

  18. Comparison of Xpert Flu rapid nucleic acid testing with rapid antigen testing for the diagnosis of influenza A and B.

    Science.gov (United States)

    DiMaio, Michael A; Sahoo, Malaya K; Waggoner, Jesse; Pinsky, Benjamin A

    2012-12-01

    Influenza infections are associated with thousands of hospital admissions and deaths each year. Rapid detection of influenza is important for prompt initiation of antiviral therapy and appropriate patient triage. In this study the Cepheid Xpert Flu assay was compared with two rapid antigen tests, BinaxNOW Influenza A & B and BD Directigen EZ Flu A+B, as well as direct fluorescent antibody testing for the rapid detection of influenza A and B. Using real-time, hydrolysis probe-based, reverse transcriptase PCR as the reference method, influenza A sensitivity was 97.3% for Xpert Flu, 95.9% for direct fluorescent antibody testing, 62.2% for BinaxNOW, and 71.6% for BD Directigen. Influenza B sensitivity was 100% for Xpert Flu and direct fluorescent antibody testing, 54.5% for BinaxNOW, and 48.5% for BD Directigen. Specificity for influenza A was 100% for Xpert Flu, BinaxNOW, and BD Directigen, and 99.2% for direct fluorescent antibody testing. All methods demonstrated 100% specificity for influenza B. These findings support the use of the Xpert Flu assay in settings requiring urgent diagnosis of influenza A and B. Copyright © 2012 Elsevier B.V. All rights reserved.

  19. Test plan for the Rapid Geophysical Surveyor

    Energy Technology Data Exchange (ETDEWEB)

    Roybal, L.G.

    1993-06-01

    This document describes the test plant for demonstrating and testing a set of optically pumped cesium-based total field magnetometers using the Rapid Geophysical Surveyor platform. The proposed testing will be used to assess the function of these magnetometers as deployed on the Rapid Geophysical Surveyor and evaluate the practical utility of high resolution magnetic data for supporting waste retrieval efforts.

  20. Behavioral and Psychological Responses to HIV Antibody Testing.

    Science.gov (United States)

    Jacobsen, Paul B.; And Others

    1990-01-01

    Considers effects of informing individuals of their antibody status as determined by human immunodeficiency virus (HIV) antibody testing. Reviews research examining changes in psychological distress and in behaviors associated with HIV infections among individuals who have undergone antibody testing. Identifies methodological issues in studying…

  1. Rapid HIV-1 testing during labor: a multicenter study.

    Science.gov (United States)

    Bulterys, Marc; Jamieson, Denise J; O'Sullivan, Mary Jo; Cohen, Mardge H; Maupin, Robert; Nesheim, Steven; Webber, Mayris P; Van Dyke, Russell; Wiener, Jeffrey; Branson, Bernard M

    2004-07-14

    Timely testing of women in labor with undocumented human immunodeficiency virus (HIV) status could enable immediate provision of antiretroviral prophylaxis. To determine the feasibility and acceptance of rapid HIV testing among women in labor and to assess rapid HIV assay performance. The Mother-Infant Rapid Intervention At Delivery (MIRIAD) study implemented 24-hour counseling and voluntary rapid HIV testing for women in labor at 16 US hospitals from November 16, 2001, through November 15, 2003. A rapid HIV-1 antibody test for whole blood was used. Acceptance of HIV testing; sensitivity, specificity, and predictive value of the rapid test; time from blood collection to patient notification of results. There were 91,707 visits to the labor and delivery units in the study, 7381 of which were by eligible women without documentation of HIV testing. Of these, 5744 (78%) women were approached for rapid HIV testing and 4849 (84%) consented. HIV-1 test results were positive for 34 women (prevalence = 7/1000). Sensitivity and specificity of the rapid test were 100% and 99.9%, respectively; positive predictive value was 90% compared with 76% for enzyme immunoassay (EIA). Factors independently associated with higher test acceptance included younger age, being black or Hispanic, gestational age less than 32 weeks, and having had no prenatal care. Lower acceptance was associated with being admitted between 4 pm and midnight, particularly on Friday nights, but this may be explained in part by fewer available personnel. Median time from blood collection to patient notification of result was 66 minutes (interquartile range, 45-120 minutes), compared with 28 hours for EIA (PHIV testing is feasible and delivers accurate and timely test results for women in labor. It provides HIV-positive women prompt access to intrapartum and neonatal antiretroviral prophylaxis, proven to reduce perinatal HIV transmission, and may be particularly applicable to higher-risk populations.

  2. Indeterminate and discrepant rapid HIV test results in couples' HIV testing and counselling centres in Africa

    Science.gov (United States)

    2011-01-01

    Background Many HIV voluntary testing and counselling centres in Africa use rapid antibody tests, in parallel or in sequence, to establish same-day HIV status. The interpretation of indeterminate or discrepant results between different rapid tests on one sample poses a challenge. We investigated the use of an algorithm using three serial rapid HIV tests in cohabiting couples to resolve unclear serostatuses. Methods Heterosexual couples visited the Rwanda Zambia HIV Research Group testing centres in Kigali, Rwanda, and Lusaka, Zambia, to assess HIV infection status. Individuals with unclear HIV rapid antibody test results (indeterminate) or discrepant results were asked to return for repeat testing to resolve HIV status. If either partner of a couple tested positive or indeterminate with the screening test, both partners were tested with a confirmatory test. Individuals with indeterminate or discrepant results were further tested with a tie-breaker and monthly retesting. HIV-RNA viral load was determined when HIV status was not resolved by follow-up rapid testing. Individuals were classified based on two of three initial tests as "Positive", "Negative" or "Other". Follow-up testing and/or HIV-RNA viral load testing determined them as "Infected", "Uninfected" or "Unresolved". Results Of 45,820 individuals tested as couples, 2.3% (4.1% of couples) had at least one discrepant or indeterminate rapid result. A total of 65% of those individuals had follow-up testing and of those individuals initially classified as "Negative" by three initial rapid tests, less than 1% were resolved as "Infected". In contrast, of those individuals with at least one discrepant or indeterminate result who were initially classified as "Positive", only 46% were resolved as "Infected", while the remainder was resolved as "Uninfected" (46%) or "Unresolved" (8%). A positive HIV serostatus of one of the partners was a strong predictor of infection in the other partner as 48% of individuals who

  3. ANCA / MPO / PR3 Antibodies Test

    Science.gov (United States)

    ... High-sensitivity C-reactive Protein (hs-CRP) Histamine Histone Antibody HIV Antibody and HIV Antigen (p24) HIV ... palpath.com . Accessed June 2010. (© 1995–2010) Unit Code 83012: Antineutrophil Cytoplasmic Antibodies Vasculitis Panel, Serum. Mayo ...

  4. Heparin-Induced Thrombocytopenia Antibody Test

    Science.gov (United States)

    ... High-sensitivity C-reactive Protein (hs-CRP) Histamine Histone Antibody HIV Antibody and HIV Antigen (p24) HIV ... Sources Used in Previous Reviews (© 1995-2011). Unit Code 81904: Heparin-PF4 Antibody (HIT), Serum. Mayo Clinic ...

  5. Rapid HIV testing for developing countries: the challenge of false-negative tests

    Science.gov (United States)

    Yogev, Ram

    2012-06-01

    It is a common practice in resource-constrained countries to accept two positive rapid HIV antibody test results as diagnostic for HIV infection. Because these tests are inexpensive and results are obtained quickly, they are recommended by the WHO to "scale-up" HIV testing to increase the number of people tested. The negative predictive value of rapid HIV tests is so high that negative results are considered conclusive despite the fact that false-negative results can occur in several situations. While the specificity and sensitivity of rapid HIV tests in resource-rich countries is acceptable, there are only limited data about their performance in resource-constrained countries. The challenges of rapid HIV testing in these situations will be discussed.

  6. A rapid online telepathy test.

    Science.gov (United States)

    Sheldrake, Rupert; Beharee, Ashwin

    2009-06-01

    In an automated online telepathy test, each participant had four senders, two actual and two virtual, generated by the computer. In a series of 12 30-sec. trials, the computer selected one of the senders at random and asked him to write a message to the subject. After 30 sec., the participant was asked to guess who had written a message. After the computer had recorded his guess, it sent him the message. In a total of 6,000 trials, there were 1,559 hits (26.7%), significantly above the chance expectation of 25%. In filmed tests, the hit rate was very similar. The hit rate with actual senders was higher than with virtual senders, but there was a strong guessing bias in favour of actual senders. When high-scoring subjects were retested, hit rates generally declined, but one subject repeatedly scored above chance.

  7. A rapid assay for Hendra virus IgG antibody detection and its titre estimation using magnetic nanoparticles and phycoerythrin.

    Science.gov (United States)

    Gao, Yuan; Pallister, Jackie; Lapierre, Florian; Crameri, Gary; Wang, Lin-Fa; Zhu, Yonggang

    2015-09-15

    Detection of Hendra viral IgG antibody in animal sera is useful for surveillance following a virus outbreak. The commonly used enzyme-linked immunosorbent assay and fluorescence-based Luminex assay typically consist of three steps and take at least several hours to complete. We have simplified the procedure to two steps in an effort to develop a rapid procedure for IgG antibody, but not IgM antibody, detection. This is achieved by conjugating the fluorescence label R-phycoerythrin directly onto the IgG binding protein Protein G. The use of magnetic nanoparticles, due to their large specific surface area, has helped reduce each of the binding steps to 20 min. As a result, the whole assay can be completed in 60 min. We also demonstrate a method to quickly estimate IgG antibody titres by assaying the sera at only two dilutions (i.e. 1:20 and 1:1000) and using the fluorescence ratio at these dilutions as an indicator of antibody titre. The results of this approach correlated well with the well-regarded serum neutralization test in virus antibody assays. This protocol reported here can be adopted in Luminex assays, fluorescence-linked immunosorbent assays and assays on microfluidics platforms for rapid antibody surveillance of Hendra and other viruses. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. HIV-Selectest enzyme immunoassay and rapid test: ability to detect seroconversion following HIV-1 infection.

    Science.gov (United States)

    Khurana, Surender; Norris, Philip J; Busch, Michael P; Haynes, Barton F; Park, Susan; Sasono, Pretty; Mlisana, Koleka; Salim, Abdool Karim; Hecht, Frederick M; Mulenga, Joseph; Chomba, Elwyn; Hunter, Eric; Allen, Susan; Nemo, George; Rodriguez-Chavez, Isaac R; Margolick, Joseph B; Golding, Hana

    2010-01-01

    HIV-Selectest is a serodiagnostic enzyme immunoassay (EIA), containing p6 and gp41 peptides, designed to differentiate between vaccine-induced antibodies and true infections. A rapid test version of the HIV-Selectest was developed. Both assays detected HIV antibodies in men and women within 2 to 4 weeks of infection, with sensitivity similar to third-generation EIAs.

  9. Evaluation of the OptiMAL Test for Rapid Diagnosis of Malaria | Ujah ...

    African Journals Online (AJOL)

    This study evaluated the ability of a newly developed rapid test for laboratory diagnosis of malaria. OptiMAL is a rapid test that utilizes a dipstick coated with monoclonal antibodies against the intracellular parasite dehydrogenase (PLDH). The differentiation of Plasmodium species is based on antigenic differences between ...

  10. The antibody mining toolbox: an open source tool for the rapid analysis of antibody repertoires.

    Science.gov (United States)

    D'Angelo, Sara; Glanville, Jacob; Ferrara, Fortunato; Naranjo, Leslie; Gleasner, Cheryl D; Shen, Xiaohong; Bradbury, Andrew R M; Kiss, Csaba

    2014-01-01

    In vitro selection has been an essential tool in the development of recombinant antibodies against various antigen targets. Deep sequencing has recently been gaining ground as an alternative and valuable method to analyze such antibody selections. The analysis provides a novel and extremely detailed view of selected antibody populations, and allows the identification of specific antibodies using only sequencing data, potentially eliminating the need for expensive and laborious low-throughput screening methods such as enzyme-linked immunosorbant assay. The high cost and the need for bioinformatics experts and powerful computer clusters, however, have limited the general use of deep sequencing in antibody selections. Here, we describe the AbMining ToolBox, an open source software package for the straightforward analysis of antibody libraries sequenced by the three main next generation sequencing platforms (454, Ion Torrent, MiSeq). The ToolBox is able to identify heavy chain CDR3s as effectively as more computationally intense software, and can be easily adapted to analyze other portions of antibody variable genes, as well as the selection outputs of libraries based on different scaffolds. The software runs on all common operating systems (Microsoft Windows, Mac OS X, Linux), on standard personal computers, and sequence analysis of 1-2 million reads can be accomplished in 10-15 min, a fraction of the time of competing software. Use of the ToolBox will allow the average researcher to incorporate deep sequence analysis into routine selections from antibody display libraries.

  11. Evaluation of a New and Rapid Serologic Test for Detecting Brucellosis: Brucella Coombs Gel Test.

    Science.gov (United States)

    Hanci, Hayrunisa; Igan, Hakan; Uyanik, Muhammet Hamidullah

    2017-01-01

    Many serological tests have been used for the diagnosis of human brucellosis. A new serological method is identified as Brucella Coombs gel test based on the principle of centrifugation gel system similar to the gel system used in blood group determination. In this system, if Brucella antibodies were present in the serum, antigen and antibody would remain as a pink complex on the gel. Otherwise, the pink Brucella antigens would precipitate at the bottom of the gel card system. In this study, we aimed to compare the Brucella Coombs gel test, a new, rapid screen and titration method for detection of non-agglutinating IgG with the Brucella Coombs test. For this study, a total of 88 serum samples were obtained from 45 healthy persons and 43 individuals who had clinical signs and symptoms of brucellosis. For each specimen, Rose Bengal test, standard agglutination test, Coombs test and Brucella Coombs gel test were carried out. Sensitivity and specificity of Brucella Coombs gel test were found as 100.0 and 82.2%, respectively. Brucella Coombs gel test can be used as a screening test with high sensitivity. By the help of pink Brucella antigen precipitation, the tests' evaluation is simple and objective. In addition, determination of Brucella antibody by rapid titration offers another important advantage.

  12. Rapid diagnostic test for identifying group B streptococcus.

    Science.gov (United States)

    Faro, Jonathan; Katz, Allan; Bishop, Karen; Riddle, Gerald; Faro, Sebastian

    2011-12-01

    Neonatal infection with Streptococcus agalactiae (group B streptococcus [GBS]) causes significant morbidity and mortality. A truly rapid diagnostic test for identifying GBS would allow for more timely initiation of antibiotic prophylaxis and also reduce the administration of antibiotics for the prevention of early onset neonatal GBS infection. A stock culture was formed from a laboratory reference strain of GBS and was diluted from 10 (7) to 10 (1) bacteria/mL. Specific concentrations were used to inoculate nitrocellulose membranes (NCMs) that had been coated previously with polyclonal rabbit antibody against GBS. After specific times, the NCMs were removed from the sheep blood agar medium, and horseradish-peroxidase conjugate polyclonal antibody against GBS was added. Bound antibody was detected with diaminobenzidine. After 6 hours of incubation, GBS was detected at concentrations from 10 (7) through 10 (4) bacterial/mL. After 4 hours of incubation, GBS was detected at concentrations from 10 (7) through 10 (5) bacteria/mL. GBS was not detected at 2 hours of incubation. Rapid growth and detection of GBS can be performed, and the results can be reliably attained as early as 4 hours. This is in marked contrast to the 48 to 72 hours required by current methods. © Thieme Medical Publishers.

  13. Application of microagglutination test for detection of antibodies to ...

    African Journals Online (AJOL)

    Application of microagglutination test for detection of antibodies to Salmonella gallinarum in commercial layer chickens Application du test de microagglutination pour la detection des anticorps a Salmonella gallinarum chez les pondeuses commerciales.

  14. Rapid high-level production of functional HIV broadly neutralizing monoclonal antibodies in transient plant expression systems.

    Directory of Open Access Journals (Sweden)

    Yvonne Rosenberg

    Full Text Available Passive immunotherapy using anti-HIV broadly neutralizing monoclonal antibodies (mAbs has shown promise as an HIV treatment, reducing mother-to-child-transmission (MTCT of simian/human immunodeficiency virus (SHIV in non-human primates and decreasing viral rebound in patients who ceased receiving anti-viral drugs. In addition, a cocktail of potent mAbs may be useful as mucosal microbicides and provide an effective therapy for post-exposure prophylaxis. However, even highly neutralizing HIV mAbs used today may lose their effectiveness if resistance occurs, requiring the rapid production of new or engineered mAbs on an ongoing basis in order to counteract the viral resistance or the spread of a certain HIV-1 clade in a particular region or patient. Plant-based expression systems are fast, inexpensive and scalable and are becoming increasingly popular for the production of proteins and monoclonal antibodies. In the present study, Agrobacterium-mediated transient transfection of plants, utilizing two species of Nicotiana, have been tested to rapidly produce high levels of an HIV 89.6PΔ140env and several well-studied anti-HIV neutralizing monoclonal antibodies (b12, 2G12, 2F5, 4E10, m43, VRC01 or a single chain antibody construct (m9, for evaluation in cell-based viral inhibition assays. The protein-A purified plant-derived antibodies were intact, efficiently bound HIV envelope, and were equivalent to, or in one case better than, their counterparts produced in mammalian CHO or HEK-293 cells in both neutralization and antibody dependent viral inhibition assays. These data indicate that transient plant-based transient expression systems are very adaptable and could rapidly generate high levels of newly identified functional recombinant HIV neutralizing antibodies when required. In addition, they warrant detailed cost-benefit analysis of prolonged incubation in plants to further increase mAb production.

  15. Rapid high-level production of functional HIV broadly neutralizing monoclonal antibodies in transient plant expression systems.

    Science.gov (United States)

    Rosenberg, Yvonne; Sack, Markus; Montefiori, David; Forthal, Donald; Mao, Lingjun; Hernandez-Abanto, Segundo; Urban, Lori; Landucci, Gary; Fischer, Rainer; Jiang, Xiaoming

    2013-01-01

    Passive immunotherapy using anti-HIV broadly neutralizing monoclonal antibodies (mAbs) has shown promise as an HIV treatment, reducing mother-to-child-transmission (MTCT) of simian/human immunodeficiency virus (SHIV) in non-human primates and decreasing viral rebound in patients who ceased receiving anti-viral drugs. In addition, a cocktail of potent mAbs may be useful as mucosal microbicides and provide an effective therapy for post-exposure prophylaxis. However, even highly neutralizing HIV mAbs used today may lose their effectiveness if resistance occurs, requiring the rapid production of new or engineered mAbs on an ongoing basis in order to counteract the viral resistance or the spread of a certain HIV-1 clade in a particular region or patient. Plant-based expression systems are fast, inexpensive and scalable and are becoming increasingly popular for the production of proteins and monoclonal antibodies. In the present study, Agrobacterium-mediated transient transfection of plants, utilizing two species of Nicotiana, have been tested to rapidly produce high levels of an HIV 89.6PΔ140env and several well-studied anti-HIV neutralizing monoclonal antibodies (b12, 2G12, 2F5, 4E10, m43, VRC01) or a single chain antibody construct (m9), for evaluation in cell-based viral inhibition assays. The protein-A purified plant-derived antibodies were intact, efficiently bound HIV envelope, and were equivalent to, or in one case better than, their counterparts produced in mammalian CHO or HEK-293 cells in both neutralization and antibody dependent viral inhibition assays. These data indicate that transient plant-based transient expression systems are very adaptable and could rapidly generate high levels of newly identified functional recombinant HIV neutralizing antibodies when required. In addition, they warrant detailed cost-benefit analysis of prolonged incubation in plants to further increase mAb production.

  16. Rapid, easy and economical dot EIA for detection of antibodies to HIV-1 using recombinant env- and gag-proteins.

    Science.gov (United States)

    Müller, R; Glathe, H; Lang, H; Simon, H; Clausnitzer, R; Petzold, G; Dittmann, S

    1991-01-01

    A rapid and simple screening test for antibodies to HIV-1 was designed on the principle of dot-EIA. Recombinant HIV-1 env and gag polypeptides are fixed on nitrocellulose sheets. Peroxidase conjugated protein A is used for detection of bound antibodies. After addition of hydrogen peroxide and 2-bromo-1-naphtol antigen-antibody complexes are visualized as discrete blue coloured spots. The test is completed within 15 min. Out of 111 sera positive by commercial EIA and Western blot analysis 110 were recognized by dot-EIA (sensitivity: 99.1%). False positive results compared with commercial EIA were found in 2 of 423 healthy blood donors (specificity: 99.5%).

  17. A Rapid Zika Diagnostic Assay to Measure Neutralizing Antibodies in Patients

    Directory of Open Access Journals (Sweden)

    Chao Shan

    2017-03-01

    Full Text Available The potential association of microcephaly and other congenital abnormalities with Zika virus (ZIKV infection during pregnancy underlines the critical need for a rapid and accurate diagnosis. Due to the short duration of ZIKV viremia in infected patients, a serologic assay that detects antibody responses to viral infection plays an essential role in diagnosing patient specimens. The current serologic diagnosis of ZIKV infection relies heavily on the labor-intensive Plaque Reduction Neutralization Test (PRNT that requires more than one-week turnaround time and represents a major bottleneck for patient diagnosis. To overcome this limitation, we have developed a high-throughput assay for ZIKV and dengue virus (DENV diagnosis that can attain the “gold standard” of the current PRNT assay. The new assay is homogeneous and utilizes luciferase viruses to quantify the neutralizing antibody titers in a 96-well format. Using 91 human specimens, we showed that the reporter diagnostic assay has a higher dynamic range and maintains the relative specificity of the traditional PRNT assay. Besides the improvement of assay throughput, the reporter virus technology has also shortened the turnaround time to less than two days. Collectively, our results suggest that, along with the viral RT-PCR assay, the reporter virus-based serologic assay could be potentially used as the first-line test for clinical diagnosis of ZIKV infection as well as for vaccine clinical trials.

  18. Evaluation of the World Health Organisation' antibody-testing ...

    African Journals Online (AJOL)

    Objective. To evaluate the World Health Organisation. (WHO) antibody testing strategy for the individual patient diagnosis of HIV infection (strategy Ill). Design. Evaluation of a combination of enzyme-linked immunosorbent assays (ELlSAs) for the detection of antibodies to HIV-1 and HIV-2 infection. The WHO strategy.

  19. Rapid detection of Hendra virus antibodies: an integrated device with nanoparticle assay and chaotic micromixing.

    Science.gov (United States)

    Petkovic, K; Metcalfe, G; Chen, H; Gao, Y; Best, M; Lester, D; Zhu, Y

    2016-12-20

    Current diagnosis of infectious diseases such as Hendra virus (HeV) relies mostly on laboratory-based tests. There is an urgent demand for rapid diagnosis technology to detect and identify these diseases in humans and animals so that disease spread can be controlled. In this study, an integrated lab-on-a-chip device using a magnetic nanoparticle immunoassay is developed. The key features of the device are the chaotic fluid mixing, achieved by magnetically driven motion of nanoparticles with the optimal mixing protocol developed using chaotic transport theory, and the automatic liquid handling system for loading reagents and samples. The device has been demonstrated to detect Hendra virus antibodies in dilute horse serum samples within a short time of 15 minutes and the limit of detection is about 0.48 ng ml -1 . The device platform can potentially be used for field detection of viruses and other biological and chemical substances.

  20. DARPA ANTIBODY TECHNOLOGY PROGRAM STANDARDIZED TEST BED FOR ANTIBODY CHARACTERIZATION: CHARACTERIZATION OF TWO MS2 SCFV ANTIBODIES PRODUCED BY THE UNIVERSITY OF TEXAS

    Science.gov (United States)

    2017-05-01

    ECBC-TR-1434 DARPA ANTIBODY TECHNOLOGY PROGRAM STANDARDIZED TEST BED FOR...COVERED (From - To) Oct 2010 – Sep 2012 4. TITLE AND SUBTITLE DARPA Antibody Technology Program Standardized Test Bed for Antibody Characterization...Characterization of Two MS2 scFv Antibodies Produced by the University of Texas 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER

  1. Diagnosis of acute mononucleosis in emergency: comparison of rapid tests

    Directory of Open Access Journals (Sweden)

    Federica Scaggiante

    2011-09-01

    Full Text Available Epstein-Barr virus (EBV is a gammaherpesvirus that causes a number of clinical syndromes, including acute mononucleosis.Acute infection with EBV can vary widely with regard to the severity and presentation of illness, ranging from an asymptomatic infection to a serious, life-threatening version of mononucleosis with associated liver damage and splenomegaly. Additionally, other acute viral syndromes, including those caused by hepatitis viruses and cytomegalovirus (CMV, can lead to similar clinical syndromes. The variety of symptoms and the overlap with other viral infections underscore the importance of laboratory testing in the diagnosis of acute EBV-related disease.The purpose of this study was to evaluate the utility of an agglutination test for the detection of heterophile antibodies (Monotest and two EBV-specific rapid immunochromatographic tests (VCA-IgM and VCA-IgG/EBNA-IgG. Heterophile antibody determination is resulted to have not a real diagnostic utility for the low sensibility and specificity of the test. In our experience the only use of VCA-IgG/EBNA-IgG test is sufficient to discriminate between an acute mononucleosis and a past infection.

  2. Sensitivity of HIV rapid tests compared with fourth-generation enzyme immunoassays or HIV RNA tests.

    Science.gov (United States)

    Tan, Wei Sheng; Chow, Eric P F; Fairley, Christopher K; Chen, Marcus Y; Bradshaw, Catriona S; Read, Tim R H

    2016-07-31

    Determine the sensitivity of HIV rapid tests compared with fourth-generation enzyme immunoassays (EIA) or nucleic acid amplification tests (NAAT) in clinical settings. Systematic review and meta-analysis. Medline, PubMed, Embase, Cochrane Controlled Trials Register, Cochrane reviews and Cumulative Index to Nursing and Allied Health Literature were searched until 14 July 2015 for studies of adults comparing point-of-care HIV rapid tests to fourth-generation HIV EIA antibody/p24 antigen or HIV NAAT. From 953 titles, 18 studies were included, involving 110 122 HIV rapid test results. Compared with EIA, the estimated sensitivity (random effects) of HIV rapid tests was 94.5% [95% confidence interval (CI): 87.4-97.7]. Compared with NAAT, the sensitivity of HIV rapid tests was 93.7% (95% CI: 88.7-96.5). The sensitivity of HIV rapid tests in high-income countries was 85.7% (95% CI: 81.9-88.9) and in low-income countries was 97.7% (95% CI: 95.2-98.9) compared with either EIA or NAAT (P HIV rapid tests were less sensitive in high-income countries compared with low-income countries, missing about one in seven infections, possibly because of the larger proportion of acute infections in targeted populations. This suggests that in high-income countries, HIV rapid tests should be used in combination with fourth-generation EIA or NAAT tests, except in special circumstances. Prospective Registration of Systematic Reviews registration number CRD42015020154.Supplementary video link: http://links.lww.com/QAD/A924.

  3. Rapid HIV Testing and Counselling in

    African Journals Online (AJOL)

    Conseil et le test rapide du VIH pendant le travail dans un milieu du Nigéria du nord Entre avril et aôut. 2004 toutes les femmes en travail à]UTH ont subi le test pour le VIH et ont reçu du conseil avec l'opportunité de refuser le test. Les femmes séro-positives reçu la monothérapie de névirapine standard shéma prophylaxie.

  4. Antibody dynamics in Holstein Friesian heifers vaccinated with Brucella abortus strain 19, using seven serological tests.

    Science.gov (United States)

    Aguirre, N P; Vanzini, V R; Torioni de Echaide, S; Valentini, B S; De Lucca, G; Aufranc, C; Canal, A; Vigliocco, A; Nielsen, K

    2002-01-01

    The serological response induced by Brucella abortus strain 19 was evaluated in 52 Holstein females from a brucellosis-free herd using seven serological tests. Each calf was vaccinated at an age of 4 and 8 months old with 3 x 10(10) CFU B. abortus S19 and the antibody response was determined as the proportion of positive results to each test. The antibody dynamics, measured with the buffered plate antigen (BPA) test and the rapid automated presumptive (RAP) test, were similar. The proportion of positive reactions in these tests reached 100% one week after vaccination and remained at this level for seven weeks, after which the proportion of positive samples slowly declined to 8% (BPA) and 2% (RAP) at week 50. The response in the indirect enzyme immunoassay (i-ELISA) was similar, but shorter than that observed with the BPA/RAP. The antibody dynamic, measured using the seroagglutination test (SAT) in parallel with the 2-mercaptoethanol (2-Me) test and the complement fixation test (CFT) were similar to the RAP/BPA, but of slightly shorter duration. The competitive ELISA (c-ELISA) was positive in all animals for 3 weeks, followed by a rapid decline. The fluorescence polarization assay (FPA) reached a maximum of 68.5% positive animals at week 4 and then declined. Based on these data, the c-ELISA and FPA discriminated residual antibody activity due to vaccination more efficiently than the other tests.

  5. Indeterminate rapid HIV-1 test results among antenatal and postnatal mothers

    OpenAIRE

    Matemo, D; Kinuthia, J.; John, F.; Chung, M.; Farquhar, C; John-Stewart, G.; Kiarie, J.

    2009-01-01

    The sensitivity and specificity of rapid HIV-1 tests may be altered during pregnancy and postpartum. We conducted a study to determine the prevalence and correlates of false-positive Abbott Determine™ and false-negative Uni-Gold™ rapid HIV-1 test results among antenatal and postnatal mothers attending a primary care clinic in Nairobi, Kenya. Mothers were tested for HIV-1 using Abbott Determine™ and non-reactive results were considered HIV-1 antibody negative. Reactive samples by Determine wer...

  6. Sensitivity and specificity of rapid HIV testing of pregnant women in India.

    Science.gov (United States)

    Bhore, A V; Sastry, J; Patke, D; Gupte, N; Bulakh, P M; Lele, S; Karmarkar, A; Bharucha, K E; Shrotri, A; Pisal, H; Suryawanshi, N; Tripathy, S; Risbud, A R; Paranjape, R S; Shankar, A V; Kshirsagar, A; Phadke, M A; Joshi, P L; Brookmeyer, R S; Bollinger, R C

    2003-01-01

    Efforts to prevent HIV transmission from mother to infants in settings like India may benefit from the availability of reliable methods for rapid and simple HIV screening. Data from India on the reliability of rapid HIV test kits are limited and there are no data on the use of rapid HIV tests for screening of pregnant women. Pregnant women attending an antenatal clinic and delivery room in Pune agreed to participate in an evaluation of five rapid HIV tests, including (a) a saliva brush test (Oraquick HIV-1/2, Orasure Technologies Inc.), (b) a rapid plasma test (Oraquick HIV-1/2) and (c) three rapid finger prick tests (Oraquick HIV-1/2; HIV-1/2 Determine, Abbott; NEVA HIV-1/2 Cadila). Results of the rapid tests were compared with three commercial plasma enzyme immunoassay (EIA) tests (Innotest HIV AB EIA, Lab systems/ELISCAN HIV AB EIA, UBI HIV Ab EIA). Between September 2000 and October 1, 2001, 1258 pregnant women were screened for HIV using these rapid tests. Forty-four (3.49%) of the specimens were HIV-antibody-positive by at least two plasma EIA tests. All of the rapid HIV tests demonstrated excellent specificity (96-100%). The sensitivity of the rapid tests ranged from 75-94%. The combined sensitivity and specificity of a two-step algorithm for rapid HIV testing was excellent for a number of combinations of the five rapid finger stick tests. In this relatively low HIV prevalence population of pregnant women in India, the sensitivity of the rapid HIV tests varied, when compared to a dual EIA algorithm. In general, the specificity of all the rapid tests was excellent, with very few false positive HIV tests. Based upon these data, two different rapid HIV tests for screening pregnant women in India would be highly sensitive, with excellent specificity to reliably prevent inappropriate use of antiretroviral therapy for prevention of vertical HIV transmission.

  7. Automated pipeline for rapid production and screening of HIV-specific monoclonal antibodies using pichia pastoris.

    Science.gov (United States)

    Shah, Kartik A; Clark, John J; Goods, Brittany A; Politano, Timothy J; Mozdzierz, Nicholas J; Zimnisky, Ross M; Leeson, Rachel L; Love, J Christopher; Love, Kerry R

    2015-12-01

    Monoclonal antibodies (mAbs) that bind and neutralize human pathogens have great therapeutic potential. Advances in automated screening and liquid handling have resulted in the ability to discover antigen-specific antibodies either directly from human blood or from various combinatorial libraries (phage, bacteria, or yeast). There remain, however, bottlenecks in the cloning, expression and evaluation of such lead antibodies identified in primary screens that hinder high-throughput screening. As such, "hit-to-lead identification" remains both expensive and time-consuming. By combining the advantages of overlap extension PCR (OE-PCR) and a genetically stable yet easily manipulatable microbial expression host Pichia pastoris, we have developed an automated pipeline for the rapid production and screening of full-length antigen-specific mAbs. Here, we demonstrate the speed, feasibility and cost-effectiveness of our approach by generating several broadly neutralizing antibodies against human immunodeficiency virus (HIV). © 2015 Wiley Periodicals, Inc.

  8. A rapid and scalable method for selecting recombinant mouse monoclonal antibodies

    Directory of Open Access Journals (Sweden)

    Wright Gavin J

    2010-06-01

    Full Text Available Abstract Background Monoclonal antibodies with high affinity and selectivity that work on wholemount fixed tissues are valuable reagents to the cell and developmental biologist, and yet isolating them remains a long and unpredictable process. Here we report a rapid and scalable method to select and express recombinant mouse monoclonal antibodies that are essentially equivalent to those secreted by parental IgG-isotype hybridomas. Results Increased throughput was achieved by immunizing mice with pools of antigens and cloning - from small numbers of hybridoma cells - the functionally rearranged light and heavy chains into a single expression plasmid. By immunizing with the ectodomains of zebrafish cell surface receptor proteins expressed in mammalian cells and screening for formalin-resistant epitopes, we selected antibodies that gave expected staining patterns on wholemount fixed zebrafish embryos. Conclusions This method can be used to quickly select several high quality monoclonal antibodies from a single immunized mouse and facilitates their distribution using plasmids.

  9. The clinical significance comparison of a latex agglutination based syphilis screening test at low antibody titer.

    Science.gov (United States)

    Wang, Hua-Cheng; Chen, Cha; Wang, Li-Na; Long, Yi-Fei; Zhang, Wei-Zheng; Li, You-Qiang; Xiao, Qian; Yuan, Hui

    2013-01-01

    The rapid increase of syphilis underscores a tremendous need to carefully evaluate many new serological tests for syphilis and choose efficient and economical strategies for syphilis screening, especially in the case of primary infection with low antibody titer. Between 2011 and 2012, 73 patients' sera samples were included in this retrospective study. They were either TRUST or TPPA reactive, either LA (latex agglutination) based auto3 TP or CLIA (chemiluminescence assay) based Architect Syphilis TP assay reactive. The contradictory weak response samples were further examined by FTA-Abs method. TPPA could not give reactive results in samples with antibody concentration less than 10 mIU. Auto3 TP reagent shows good linearity at low antibody titers and was more sensitive than TPPA, while the former does not show significant superiority compared to the Architect Syphilis TP assay at low antibody titer, except that it is suitable for adaptation on diverse automated chemistry analyzers.

  10. ANCA / MPO / PR3 Antibodies Test

    Science.gov (United States)

    ... Testing Leptin Levetiracetam Lipase Lipid Profile Lipoprotein (a) Lithium Liver Panel Lp-PLA2 Lupus Anticoagulant Testing Luteinizing ... What is Vasculitis? Crohn's and Colitis Foundation of America: Diagnosing and Managing IBD National Digestive Diseases Information ...

  11. A novel double antibody sandwich-lateral flow immunoassay for the rapid and simple detection of hepatitis C virus.

    Science.gov (United States)

    Xiang, Tingxiu; Jiang, Zheng; Zheng, Jian; Lo, Chaoyu; Tsou, Harry; Ren, Guosheng; Zhang, Jun; Huang, Ailong; Lai, Guoqi

    2012-11-01

    The objective of this study was to screen for antigens of the hepatitis C virus (HCV) to establish a new double antibody sandwich-lateral flow immunoassay (DAS-LFIA) method for testing the presence of anti-HCV antibodies in human serum or plasma. A series of different recombinant HCV proteins in Escherichia coli cells were constructed, expressed, purified and the new DAS-LFIA strip was developed. The sensitivity and specificity of new the DAS-LFIA strip were evaluated by detecting 23 HCV-positive sera, a set of quality control references for anti-HCV detection that contain known amounts of anti-HCV antibodies, and 8 HCV-negative sera. A total of 300 clinical serum samples was examined by both the new DAS-LFIA strip and enzyme-linked immunosorbent assay (ELISA). Data were analyzed using SPSS 11.5 software. The sensitivity and specificity of the new DAS-LFIA strip were 100%. The lowest test line of the HCV DAS-LFIA strips was 2 NCU/ml. Additionally, the concordance between the new DAS-LFIA strip and ELISA methods was 94.33%. In conclusion, our new testing method is rapid, simple, sensitive and specifically detects the presence of anti-HCV antibodies in human serum or plasma. Therefore, it may be used for monitoring HCV.

  12. Functionally Active Fc Mutant Antibodies Recognizing Cancer Antigens Generated Rapidly at High Yields

    Directory of Open Access Journals (Sweden)

    Kristina M. Ilieva

    2017-09-01

    Full Text Available Monoclonal antibodies find broad application as therapy for various types of cancer by employing multiple mechanisms of action against tumors. Manipulating the Fc-mediated functions of antibodies that engage immune effector cells, such as NK cells, represents a strategy to influence effector cell activation and to enhance antibody potency and potentially efficacy. We developed a novel approach to generate and ascertain the functional attributes of Fc mutant monoclonal antibodies. This entailed coupling single expression vector (pVitro1 antibody cloning, using polymerase incomplete primer extension (PIPE polymerase chain reaction, together with simultaneous Fc region point mutagenesis and high yield transient expression in human mammalian cells. Employing this, we engineered wild type, low (N297Q, NQ, and high (S239D/I332E, DE FcR-binding Fc mutant monoclonal antibody panels recognizing two cancer antigens, HER2/neu and chondroitin sulfate proteoglycan 4. Antibodies were generated with universal mutagenic primers applicable to any IgG1 pVitro1 constructs, with high mutagenesis and transfection efficiency, in small culture volumes, at high yields and within 12 days from design to purified material. Antibody variants conserved their Fab-mediated recognition of target antigens and their direct anti-proliferative effects against cancer cells. Fc mutations had a significant impact on antibody interactions with Fc receptors (FcRs on human NK cells, and consequently on the potency of NK cell activation, quantified by immune complex-mediated calcium mobilization and by antibody-dependent cellular cytotoxicity (ADCC of tumor cells. This strategy for manipulation and testing of Fc region engagement with cognate FcRs can facilitate the design of antibodies with defined effector functions and potentially enhanced efficacy against tumor cells.

  13. Refolded scFv Antibody Fragment against Myoglobin Shows Rapid Reaction Kinetics

    Directory of Open Access Journals (Sweden)

    Hyung-Nam Song

    2014-12-01

    Full Text Available Myoglobin is one of the early biomarkers for acute myocardial infarction. Recently, we have screened an antibody with unique rapid reaction kinetics toward human myoglobin antigen. Antibodies with rapid reaction kinetics are thought to be an early IgG form produced during early stage of in vivo immunization. We produced a recombinant scFv fragment for the premature antibody from Escherichia coli using refolding technology. The scFv gene was constructed by connection of the VH–VL sequence with a (Gly4Ser3 linker. The scFv fragment without the pelB leader sequence was expressed at a high level, but the solubility was extremely low. A high concentration of 8 M urea was used for denaturation. The dilution refolding process in the presence of arginine and the redox reagents GSH and GSSH successfully produced a soluble scFv protein. The resultant refolded scFv protein showed association and dissociation values of 9.32 × 10−4 M−1·s−1 and 6.29 × 10−3 s−1, respectively, with an affinity value exceeding 107 M−1 (kon/koff, maintaining the original rapid reaction kinetics of the premature antibody. The refolded scFv could provide a platform for protein engineering for the clinical application for diagnosis of heart disease and the development of a continuous biosensor.

  14. Utility of HLA Antibody Testing in Kidney Transplantation

    Science.gov (United States)

    Konvalinka, Ana

    2015-01-01

    HLA antigens are polymorphic proteins expressed on donor kidney allograft endothelium and are critical targets for recipient immune recognition. HLA antibodies are risk factors for acute and chronic rejection and allograft loss. Solid-phase immunoassays for HLA antibody detection represent a major advance in sensitivity and specificity over cell-based methods and are widely used in organ allocation and pretransplant risk assessment. Post-transplant, development of de novo donor–specific HLA antibodies and/or increase in donor-specific antibodies from pretransplant levels are associated with adverse outcomes. Although single antigen bead assays have allowed sensitive detection of recipient HLA antibodies and their specificities, a number of interpretive considerations must be appreciated to understand test results in clinical and research contexts. This review, which is especially relevant for clinicians caring for transplant patients, discusses the technical aspects of single antigen bead assays, emphasizes their quantitative limitations, and explores the utility of HLA antibody testing in identifying and managing important pre- and post-transplant clinical outcomes. PMID:25804279

  15. Epstein-Barr Virus Antibodies Test

    Science.gov (United States)

    ... a Glance Why Get Tested? To help diagnose infectious mononucleosis (mono); to distinguish between an Epstein-Barr virus ( ... initial infection occurs in adolescence, it can cause infectious mononucleosis, commonly called mono, a condition associated with fatigue, ...

  16. Comparison of the Fluorescent Antibody Test and Direct Microscopic ...

    African Journals Online (AJOL)

    One hundred and eighty-nine (189) dog brain samples submitted to the National Veterinary Research Institute, Vom, Nigeria for rabies diagnosis were assayed by the Direct Microscopic Examination (DME) for Negri bodies, the Fluorescent Antibody Test (FAT) for rabies antigens, and the Mouse Inoculation Test (MIT).

  17. A rapid test for soy aeroallergens exposure assessment.

    Science.gov (United States)

    Alvarez-Simon, Daniel; Cruz, María-Jesús; Untoria, María-Dolores; Muñoz, Xavier; Villalbí, Joan R; Morell, Ferran; Gómez-Ollés, Susana

    2014-01-01

    Determining soy aeroallergens levels is extremely important in the assessment of health risks due to these airborne substances. Currently, soy aeroallergens exposure in the environment is monitored using enzyme immunoassays (EIA) which must be evaluated in a specialized laboratory by skilled personnel. To describe the development and performance of a rapid immunochromatography assay for the detection of soy aeroallergens in environmental samples. A test strip using gold labeled anti-soy hull low molecular weight extract (SHLMWE) antibody for the rapid detection of soy aeroallergens in environmental samples was developed. One hundred nineteen airborne samples were analysed in parallel by the strip assay and the anti-SHLMWE sandwich EIA. The assay results were visually analysed by three independent observers who ranked samples as: -, + or ++. Strips were also scanned and analysed by densitometry. The rapid test detected a range of concentrations from 6.25 to 25 ng/mL. Agreement in strip assay interpretations between evaluators was substantial (Kappa = 0.63; CI 0.544-0.715). Visual interpretation also gave a good concordance with EIA results, with sensitivity ranging from 77.3 to 100 and specificity from 65 to 83.5 depending on the observer. Furthermore, a strong correlation was observed between densitometry results of strip assay and EIA determinations. The strip assay developed is rapid, simple, and sensitive and does not require expensive equipment or specific skills. It has considerable potential in the environmental monitoring field for screening soy aeroallergens levels in port cities where allergen measurements are not currently performed. Due to its simplicity, the test will improve the management of soy allergic patients by controlling environmental allergen exposure without the need for apparatus or skilled personnel.

  18. [Rapid antibiotic susceptibility test in Clinical Microbiology].

    Science.gov (United States)

    March Rosselló, Gabriel Alberto; Bratos Pérez, Miguel Ángel

    2016-01-01

    The most widely used antibiotic susceptibility testing methods in Clinical Microbiology are based on the phenotypic detection of antibiotic resistance by measuring bacterial growth in the presence of the antibiotic being tested. These conventional methods take typically 24hours to obtain results. A review is presented here of recently developed techniques for the rapid determination of antibiotic susceptibility. Data obtained with different methods such as molecular techniques, flow cytometry, chemiluminescence, mass spectrometry, commercial methods used in routine work, colorimetric methods, nephelometry, microarrays, microfluids, and methods based on cell disruption and sequencing, are analyzed and discussed in detail. Copyright © 2014 Elsevier España, S.L.U. y Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.

  19. Rapid Assay for Simultaneous Detection and Differentiation of Immunoglobulin G Antibodies to Human Immunodeficiency Virus Type 1 (HIV-1) Group M, HIV-1 Group O, and HIV-2

    OpenAIRE

    Vallari, Ana S.; Hickman, Robert K.; Hackett, John R.; Brennan, Catherine A.; Varitek, Vincent A.; Devare, Sushil G.

    1998-01-01

    A rapid immunodiagnostic test that detects and discriminates human immunodeficiency virus (HIV) infections on the basis of viral type, HIV type 1 (HIV-1) group M, HIV-1 group O, or HIV-2, was developed. The rapid assay for the detection of HIV (HIV rapid assay) was designed as an instrument-free chromatographic immunoassay that detects immunoglobulin G (IgG) antibodies to HIV. To assess the performance of the HIV rapid assay, 470 HIV-positive plasma samples were tested by PCR and/or Western b...

  20. Comparative Evaluation of Seven Commercial Tests for Detection of Heterophile Antibody in Infectious Mononucleosis

    Directory of Open Access Journals (Sweden)

    Martin Skulnick

    1992-01-01

    Full Text Available Detection of heterophile antibodies in infectious mononucleosis is the most rapid and cost-effective method for confirming the clinical diagnosis of the disease. This study compared seven commercial test kits (the Oxoid Infectious Mononucleosis Kit [Oxoid Ltd], Immunoscan Im-Latex [Baxter Travenol], Mono-Latex [Wampole Laboratories], Monospot and Im Screen Test [Ortho Diagnostics], Immunoscan Im-RBC Test [Baxter Travenol], and Infectious Mononucleosis Test [NCS Diagnostics] to the Davidsohn differential test. All of the kits were shown to be acceptable for use, with specificities and sensitivities greater than 96.5% and 95.5%, respectively.

  1. Development of a blocking latex agglutination test for the detection of antibodies to chicken anemia virus.

    Science.gov (United States)

    Trinh, Dai Quang; Ogawa, Haruko; Bui, Vuong Nghia; Nguyen, Tham Thi Hong; Gronsang, Dulyatad; Baatartsogt, Tugsbaatar; Kizito, Mugimba Kahoza; AboElkhair, Mohammed; Yamaguchi, Shigeo; Nguyen, Viet Khong; Imai, Kunitoshi

    2015-09-01

    A blocking latex agglutination test (b-LAT) developed in this study was evaluated for the detection of antibodies against chicken anemia virus (CAV) in chickens. Polystyrene latex beads were coupled with a neutralizing monoclonal antibody (mAb) to CAV (mAb-beads). When mAb-beads were mixed with antigens prepared from the lysate of MDCC-MSB1 cells infected with CAV, agglutination occurred. A short pre-incubation of CAV antigens with CAV-specific antiserum inhibited the agglutination of mAb-beads. The test results were obtained within 5min. The specificity of b-LAT was evaluated using sera from specific pathogen-free chickens and sera containing antibodies to avian influenza virus, Newcastle disease virus, infectious bursal disease virus, and Marek's disease virus; nonspecific agglutination and cross-reactivity with antibodies to unrelated viruses were not observed. The examination of 94 serum samples collected from commercial breeder chickens of various ages (17-63 weeks) revealed good agreement (93.6%, Kappa value=0.82) between b-LAT and a virus neutralization test, known to be most sensitive and specific in the detection of antibodies to CAV. These results indicate that b-LAT, a simple and rapid test, is a useful and reliable tool in CAV serology. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. False-positive human immunodeficiency virus antibody test in a dialysis patient.

    Science.gov (United States)

    Silverstein, Douglas M; Aviles, Diego H; Vehaskari, V Matti

    2004-05-01

    A patient developed end-stage renal disease secondary to p-anti-neutrophil cytoplasmic antibody (p-ANCA) positive rapidly progressive glomerulonephritis. He subsequently had human immunodeficiency virus (HIV)-1 antibody screening performed as part of a pre-transplant evaluation. The HIV-1 enzyme immunoassay (EIA) antibody test was repeatedly reactive. The HIV-1 western blot was indeterminate. The western blot pattern revealed "non-specific staining obscuring bands in that region." Another sample of serum was sent and the results were identical to the first result. An HIV-1 proviral qualitative polymerase chain reaction test was then performed several months later and no HIV-1 DNA was detected. One year later, an HIV-1 RNA test was negative. Thus, the positive antibody EIA test and the indeterminate western blot represent a false-positive result, most likely due to cross-reacting antigens in the patient's serum with various HIV antibodies. Throughout this period and thereafter, the patient has exhibited no symptoms of HIV infection.

  3. Rapid non-invasive tests for diagnostics of infectious diseases

    Science.gov (United States)

    Malamud, Daniel

    2014-06-01

    A rapid test for an infectious disease that can be used at point-of-care at a physician's office, a pharmacy, or in the field is critical for the prompt and appropriate therapeutic intervention. Ultimately by treating infections early on will decrease transmission of the pathogen. In contrast to metabolic diseases or cancer where multiple biomarkers are required, infectious disease targets (e.g. antigen, antibody, nucleic acid) are simple and specific for the pathogen causing the disease. Our laboratory has focused on three major infectious disease; HIV, Tuberculosis, and Malaria. These diseases are pandemic in much of the world thus putting natives, tourists and military personnel at risk for becoming infected, and upon returning to the U.S., transmitting these diseases to their contacts. Our devices are designed to detect antigens, antibodies or nucleic acids in blood or saliva samples in less than 30 minutes. An overview describing the current status of each of the three diagnostic platforms is presented. These microfluidic point-of-care devices will be relatively inexpensive, disposable, and user friendly.

  4. How to use … the Monospot and other heterophile antibody tests.

    Science.gov (United States)

    Marshall-Andon, Tess; Heinz, Peter

    2017-08-01

    Epstein-Barr virus (EBV) is a highly prevalent virus, transmitted via saliva, which often causes asymptomatic infection in children but frequently results in infectious mononucleosis in adolescents. Heterophile antibody tests, including the Monospot test, are red cell or latex agglutination assays, which detect antired cell antibodies produced as part of a polyclonal antibody response occurring during EBV infection. Heterophile antibody tests are rapid, cheap and specific tests that can be performed from the onset of symptoms of infectious mononucleosis. In adolescents, heterophile antibody tests have high specificity and sensitivity in the diagnosis of primary acute EBV infection. However, the tests have low sensitivity and low negative predictive value in young children and are not useful under the age of 4. Heterophile tests may be positive in other viral infections, autoimmune disease and haematological malignancies, but do not appear to be positive in primary bacterial infection. Virus-specific serology is required in children under the age of 4 or if an older child is heterophile negative. Virus-specific serology allows diagnosis and the pattern of positivity and negativity enables the clinician to stage the EBV infection. Virus-specific serology appears to have better sensitivity in young children, but there is cross-reaction with other herpesvirus infections, a longer turnaround time and it is more expensive to perform. Further research is needed to establish which children benefit from and hence require testing for heterophile antibodies, the cost-effectiveness of EBV investigations and whether heterophile titres have predictive value for the severity of infection and the likelihood of complications. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  5. A Global Comparative Evaluation of Commercial Immunochromatographic Rapid Diagnostic Tests for Visceral Leishmaniasis

    NARCIS (Netherlands)

    Cunningham, Jane; Hasker, Epco; Das, Pradeep; El Safi, Sayda; Goto, Hiro; Mondal, Dinesh; Mbuchi, Margaret; Mukhtar, Maowia; Rabello, Ana; Rijal, Suman; Sundar, Shyam; Wasunna, Monique; Adams, Emily; Menten, Joris; Peeling, Rosanna; Boelaert, Marleen; Khanal, Basudha; Das, Murari; Oliveira, Edward; de Assis, Tália Machado; Costa, Dorcas Lamounier; Bhaskar, Khondaker Rifathassan; Huda, M. Mamun; Hassan, Mukidul; Abdoun, Asim Osman; Awad, Aymen; Osman, Mohamed; Prajapati, Dinesh Kumar; Gidwani, Kamlesh; Tiwary, Puja; Paniago, Anamaria Mello Miranda; Sanchez, Maria Carmen Arroyo; Celeste, Beatriz Julieta; Jacquet, Diane; Magiri, Charles; Muia, A.; Kesusu, J.; Ageed, Al Farazdag; Galal, Nuha; Osman, Osman Salih; Gupta, A. K.; Bimal, Afrad S.; Das, V. N. R.

    2012-01-01

    Background. Poor access to diagnosis stymies control of visceral leishmaniasis (VL). Antibody-detecting rapid diagnostic tests (RDTs) can be performed in peripheral health settings. However, there are many brands available and published reports of variable accuracy. Methods. Commercial VL RDTs

  6. An automated robotic platform for rapid profiling oligosaccharide analysis of monoclonal antibodies directly from cell culture.

    Science.gov (United States)

    Doherty, Margaret; Bones, Jonathan; McLoughlin, Niaobh; Telford, Jayne E; Harmon, Bryan; DeFelippis, Michael R; Rudd, Pauline M

    2013-11-01

    Oligosaccharides attached to Asn297 in each of the CH2 domains of monoclonal antibodies play an important role in antibody effector functions by modulating the affinity of interaction with Fc receptors displayed on cells of the innate immune system. Rapid, detailed, and quantitative N-glycan analysis is required at all stages of bioprocess development to ensure the safety and efficacy of the therapeutic. The high sample numbers generated during quality by design (QbD) and process analytical technology (PAT) create a demand for high-performance, high-throughput analytical technologies for comprehensive oligosaccharide analysis. We have developed an automated 96-well plate-based sample preparation platform for high-throughput N-glycan analysis using a liquid handling robotic system. Complete process automation includes monoclonal antibody (mAb) purification directly from bioreactor media, glycan release, fluorescent labeling, purification, and subsequent ultra-performance liquid chromatography (UPLC) analysis. The entire sample preparation and commencement of analysis is achieved within a 5-h timeframe. The automated sample preparation platform can easily be interfaced with other downstream analytical technologies, including mass spectrometry (MS) and capillary electrophoresis (CE), for rapid characterization of oligosaccharides present on therapeutic antibodies. Copyright © 2013 Elsevier Inc. All rights reserved.

  7. Development of a double-antibody sandwich ELISA for rapid detection of Bacillus Cereus in food

    Science.gov (United States)

    Zhu, Longjiao; He, Jing; Cao, Xiaohan; Huang, Kunlun; Luo, Yunbo; Xu, Wentao

    2016-01-01

    Bacillus cereus is increasingly recognized as one of the major causes of food poisoning in the industrialized world. In this paper, we describe a sensitive double-antibody sandwich enzyme-linked immunosorbent assay (ELISA) that was developed for rapid detection of B. cereus in food to minimize the risk of contamination. The polyclonal antibody (pAb) and monoclonal antibodies (mAbs) specific to B. cereus were generated from rabbit antiserum and mouse ascites, respectively, using the octanoic acid/saturated ammonium sulfate precipitation method and protein A-sepharose columns. IgG-isotype mAbs were specially developed to undergo a novel peripheral multiple sites immunization for rapid gain of hybridomas and a subtractive screen was used to eliminate cross reactivity with closely related species such as Bacillus thuringiensis, B. subtilis, B. licheniformis and B. perfringens. The linear detection range of the method was approximately 1 × 104–2.8 × 106 cells/mL with a detection limit (LOD) of 0.9 × 103 cells/mL. The assay was able to detect B. cereus when the samples were prepared in meat with various pathogens. The newly developed analytical method provides a rapid method to sensitively detect B. cereus in food specimens. PMID:26976753

  8. High-content analysis of antibody phage-display library selection outputs identifies tumor selective macropinocytosis-dependent rapidly internalizing antibodies.

    Science.gov (United States)

    Ha, Kevin D; Bidlingmaier, Scott M; Zhang, Yafeng; Su, Yang; Liu, Bin

    2014-12-01

    Many forms of antibody-based targeted therapeutics, including antibody drug conjugates, utilize the internalizing function of the targeting antibody to gain intracellular entry into tumor cells. Ideal antibodies for developing such therapeutics should be capable of both tumor-selective binding and efficient endocytosis. The macropinocytosis pathway is capable of both rapid and bulk endocytosis, and recent studies have demonstrated that it is selectively up-regulated by cancer cells. We hypothesize that receptor-dependent macropinocytosis can be achieved using tumor-targeting antibodies that internalize via the macropinocytosis pathway, improving potency and selectivity of the antibody-based targeted therapeutic. Although phage antibody display libraries have been utilized to find antibodies that bind and internalize to target cells, no methods have been described to screen for antibodies that internalize specifically via macropinocytosis. We hereby describe a novel screening strategy to identify phage antibodies that bind and rapidly enter tumor cells via macropinocytosis. We utilized an automated microscopic imaging-based, High Content Analysis platform to identify novel internalizing phage antibodies that colocalize with macropinocytic markers from antibody libraries that we have generated previously by laser capture microdissection-based selection, which are enriched for internalizing antibodies binding to tumor cells in situ residing in their tissue microenvironment (Ruan, W., Sassoon, A., An, F., Simko, J. P., and Liu, B. (2006) Identification of clinically significant tumor antigens by selecting phage antibody library on tumor cells in situ using laser capture microdissection. Mol. Cell. Proteomics. 5, 2364-2373). Full-length human IgG molecules derived from macropinocytosing phage antibodies retained the ability to internalize via macropinocytosis, validating our screening strategy. The target antigen for a cross-species binding antibody with a highly active

  9. High-content Analysis of Antibody Phage-display Library Selection Outputs Identifies Tumor Selective Macropinocytosis-dependent Rapidly Internalizing Antibodies*

    Science.gov (United States)

    Ha, Kevin D.; Bidlingmaier, Scott M.; Zhang, Yafeng; Su, Yang; Liu, Bin

    2014-01-01

    Many forms of antibody-based targeted therapeutics, including antibody drug conjugates, utilize the internalizing function of the targeting antibody to gain intracellular entry into tumor cells. Ideal antibodies for developing such therapeutics should be capable of both tumor-selective binding and efficient endocytosis. The macropinocytosis pathway is capable of both rapid and bulk endocytosis, and recent studies have demonstrated that it is selectively up-regulated by cancer cells. We hypothesize that receptor-dependent macropinocytosis can be achieved using tumor-targeting antibodies that internalize via the macropinocytosis pathway, improving potency and selectivity of the antibody-based targeted therapeutic. Although phage antibody display libraries have been utilized to find antibodies that bind and internalize to target cells, no methods have been described to screen for antibodies that internalize specifically via macropinocytosis. We hereby describe a novel screening strategy to identify phage antibodies that bind and rapidly enter tumor cells via macropinocytosis. We utilized an automated microscopic imaging-based, High Content Analysis platform to identify novel internalizing phage antibodies that colocalize with macropinocytic markers from antibody libraries that we have generated previously by laser capture microdissection-based selection, which are enriched for internalizing antibodies binding to tumor cells in situ residing in their tissue microenvironment (Ruan, W., Sassoon, A., An, F., Simko, J. P., and Liu, B. (2006) Identification of clinically significant tumor antigens by selecting phage antibody library on tumor cells in situ using laser capture microdissection. Mol. Cell. Proteomics. 5, 2364–2373). Full-length human IgG molecules derived from macropinocytosing phage antibodies retained the ability to internalize via macropinocytosis, validating our screening strategy. The target antigen for a cross-species binding antibody with a highly

  10. The rise of targeted HIV oral rapid testing in Australia.

    Science.gov (United States)

    Chan, Derek; Stewart, Michael; Smith, Maggie; Price, Tony; Lusk, Jo; Ooi, Catriona; Read, Phillip; Finlayson, Robert

    2015-03-16

    To assess the performance and acceptability of the OraQuick Advance Rapid HIV-1/2 Antibody Test (ORT) in Australia. Cross-sectional study of 1074 men who have sex with men (MSM) and individuals aged 18 years or older at high risk of acquiring HIV infection who attended five public HIV or sexual health services, two general practices and one community clinic in Sydney from 1 January to 31 December 2013. One ORT confirmed by fourth-generation HIV enzyme immunoassay (EIA). ORT sensitivity and specificity compared with EIA; acceptabiity of the ORT to participants. 83.5% of participants were MSM, 90.3% were aged under 50 years, and 9% had never been tested for HIV. There were 11 true-positive ORT results, two false-negative (non-reactive) results (both were early infections), and one false-positive (reactive) result (due to reader error). Sensitivity and specificity were 84.6% and 99.8%, respectively (compared with a sensitivity of 99.3% and specificity of 99.8% listed by the manufacturer). Three quarters of participants (74.0%; 730/987) found the ORT less stressful than venous sampling. Those who usually had tests at intervals of greater than 3 months deemed the ORT less stressful than those who had quarterly tests (77.5% v 64.8%; Ptesting. ORT sensitivity is reduced in early HIV infection. The test is highly acceptable and less stressful than venous sampling. Participants are keen to be tested with the ORT in future, would recommend it to peers and would have tests more frequently if the ORT were licensed. TGA approval of this test might slow increasing HIV infection rates among MSM and others by facilitating diagnosis and treatment.

  11. Lateral flow-based antibody testing for Chlamydia trachomatis.

    Science.gov (United States)

    Gwyn, Sarah; Mitchell, Alexandria; Dean, Deborah; Mkocha, Harran; Handali, Sukwan; Martin, Diana L

    2016-08-01

    We describe here a lateral flow-based assay (LFA) for the detection of antibodies against immunodominant antigen Pgp3 from Chlamydia trachomatis, the causative agent of urogenital chlamydia infection and ocular trachoma. Optimal signal detection was achieved when the gold-conjugate and test line contained Pgp3, creating a dual sandwich capture assay. The LFA yielded positive signals with serum and whole blood but not with eluted dried blood spots. For serum, the agreement of the LFA with the non-reference multiplex assay was 96%, the specificity using nonendemic pediatric sera was 100%, and the inter-rater agreement was κ=0.961. For whole blood, the agreement of LFA with multiplex was 81.5%, the specificity was 100%, and the inter-rater agreement was κ=0.940. The LFA was tested in a field environment and yielded similar results to those from laboratory-based testing. These data show the successful development of a lateral flow assay for detection of antibodies against Pgp3 with reliable use in field settings, which would make antibody-based testing for trachoma surveillance highly practical, especially after cessation of trachoma elimination programs. Published by Elsevier B.V.

  12. Rapid high yield production of different glycoforms of Ebola virus monoclonal antibody.

    Directory of Open Access Journals (Sweden)

    Alexandra Castilho

    Full Text Available Fc-glycosylation of monoclonal antibodies (mAbs has profound implications on the Fc-mediated effector functions. Alteration of this glycosylation may affect the efficiency of an antibody. However, difficulties in the production of mAbs with homogeneous N-glycosylation profiles in sufficient amounts hamper investigations of the potential biological impact of different glycan residues.Here we set out to evaluate a transient plant viral based production system for the rapid generation of different glycoforms of a monoclonal antibody. Ebola virus mAb h-13F6 was generated using magnICON expression system in Nicotiana benthamiana, a plant species developed for commercial scale production of therapeutic proteins. h-13F6 was co-expressed with a series of modified mammalian enzymes involved in the processing of complex N-glycans. Using wild type (WT plants and the glycosylation mutant ΔXTFT that synthesizes human like biantennary N-glycans with terminal N-acetylglucosamine on each branch (GnGn structures as expression hosts we demonstrate the generation of h-13F6 complex N-glycans with (i bisected structures, (ii core α1,6 fucosylation and (iii β1,4 galactosylated oligosaccharides. In addition we emphasize the significance of precise sub Golgi localization of enzymes for engineering of IgG Fc-glycosylation.The method described here allows the efficient generation of a series of different human-like glycoforms at large homogeneity of virtually any antibody within one week after cDNA delivery to plants. This accelerates follow up functional studies and thus may contribute to study the biological role of N-glycan residues on Fcs and maximizing the clinical efficacy of therapeutic antibodies.

  13. Rapid diagnosis of bacterial meningitis by latex agglutination test.

    Science.gov (United States)

    Abdel-Ghani, S M; Hassan, E M; Masoud, S; Guirgis, N I

    1989-01-01

    Forty-three patients admitted to Abassia Fever Hospital suffering from meningitis were studied. They were 27 male and 16 female and divided into 3 age groups, as a control, 4 normal CSF samples were collected. A sterile CSF was collected and examined for pressure, aspect, glucose, protein and cellular content. Although all these tests were helpful in differentiating the type of meningitis, a remarkable overlap between the results were detected. Bacteriological study of CSF showed that bacterial culture was more sensitive than the Gram-stained film in (80% and 72% respectively) (p less than 0.05). However, it is a time consuming and its results greatly affected by prior uses of antibiotics. Also the antigen of N. meningitidis A & C, H. influenzae and S. pneumoniae were detected by latex agglutination (L.A.) and gave positive results in 76% of cases. It was less sensitive than the culture method. As a conclusion, L.A. test is a rapid and simple method of diagnosis of bacterial meningitis which give immediate information to the clinician. The sensitivity and specificity of L.A. can be greatly improved by using a higher quality of antibody for all serotypes in the locality.

  14. Antibody

    Science.gov (United States)

    An antibody is a protein produced by the body's immune system when it detects harmful substances, called antigens. Examples ... microorganisms (bacteria, fungi, parasites, and viruses) and chemicals. Antibodies may be produced when the immune system mistakenly ...

  15. Performance of rapid point-of-care and laboratory tests for acute and established HIV infection in San Francisco.

    Directory of Open Access Journals (Sweden)

    Christopher D Pilcher

    Full Text Available Current laboratory and point-of-care tests for HIV detect different analytes and use different sample types. Some have fast turnaround times (<1 hour. We investigated how HIV test choice could impact case finding by testing programs.We analyzed 21,234 consecutive HIV tests with venous blood obtained by San Francisco HIV testing programs from 2003 to 2008. For a subset, oral fluid (n = 6446 or fingerstick blood (n = 8127 samples were also obtained for rapid testing. In all cases, HIV status was determined using an HIV antibody-plus-RNA test algorithm. We assessed how the screening antibody tests performed individually versus the gold standard of the full algorithm. We then evaluated the potential ability of other tests (including new tests to detect more cases, by re-testing all specimens that had negative/discrepant antibody results on initial screening.The antibody-RNA algorithm identified 58 acute and 703 established HIV infection cases. 1(st-generation (Vironostika and 3(rd-generation (Genetic Systems immunoassays had 92 and 96 percent sensitivity, respectively. The Oraquick rapid test had clinical sensitivity of only 86 percent on oral fluid samples, but 92 percent on finger-stick blood. Newer 4(th-generation, antigen-antibody combo rapid immunoassay (ARCHITECT detected HIV in 87 percent of all the acute cases that had been missed by one of the previous screening assays. A point-of-care 4(th generation antigen-antibody combo rapid test (Determine detected about 54 percent of such acute cases.Our study suggests that some rapid antibody blood tests will give similar case detection to laboratory antibody tests, but that oral fluid testing greatly reduces ability to detect HIV. New 4(th-generation combo tests can detect the majority of acute infections detectable by HIV RNA but with rapid results. Using these tests as a primary screening assay in high-risk HIV testing programs could reduce or eliminate the need for HIV RNA testing.

  16. Ultrasensitive cardiac troponin I antibody based nanohybrid sensor for rapid detection of human heart attack.

    Science.gov (United States)

    Bhatnagar, Deepika; Kaur, Inderpreet; Kumar, Ashok

    2017-02-01

    An ultrasensitive cardiac troponin I antibody conjugated with graphene quantum dots (GQD) and polyamidoamine (PAMAM) nanohybrid modified gold electrode based sensor was developed for the rapid detection of heart attack (myocardial infarction) in human. Screen printed gold (Au) electrode was decorated with 4-aminothiophenol for amine functionalization of the Au surface. These amino groups were further coupled with carboxyl functionalities of GQD with EDC-NHS reaction. In order to enhance the sensitivity of the sensor, PAMAM dendrimer was successively embedded on GQD through carbodiimide coupling to provide ultra-high surface area for antibody immobilization. The activated cardiac troponin I (cTnI) monoclonal antibody was immobilized on PAMAM to form nanoprobe for sensing specific heart attack marker cTnI. Various concentrations of cardiac marker, cTnI were electrochemically measured using cyclic voltammetry (CV) and differential pulse voltammetry (DPV) in human blood serum. The modifications on sensor surface were characterized by FTIR and AFM techniques. The sensor is highly specific to cTnI and showed negligible response to non-specific antigens. The sensitivity of the sensor was 109.23μAcm(-2)μg(-1) and lower limit of detection of cTnI was found 20fgmL(-1). Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Rapidly progressive antineutrophil cytoplasm antibodies associated with pulmonary-renal syndrome in a 10-year-old girl

    Directory of Open Access Journals (Sweden)

    Fermin Blanco Filho

    2001-01-01

    Full Text Available CONTEXT: The term pulmonary-renal syndrome has been used frequently to describe the clinical manifestations of a great number of diseases in which pulmonary hemorrhage and glomerulonephritis coexist. The classic example of this type of vasculitis is Goodpasture´s syndrome, a term used to describe the association of pulmonary hemorrhage, glomerulonephritis and the presence of circulating antiglomerular basement membrane antibodies (anti-GBM. Among the several types of systemic vasculitides that can present clinical manifestations of the pulmonary-renal syndrome, we focus the discussion on two types more frequently associated with antineutrophil cytoplasm antibodies (ANCA, microscopic polyangiitis and Wegener´s granulomatosis, concerning a 10 year old girl with clinical signs and symptoms of pulmonary-renal syndrome, with positive ANCA and rapidly progressive evolution. CASE REPORT: We describe the case of a 10-year-old girl referred to our hospital for evaluation of profound anemia detected in a primary health center. Five days before entry she had experienced malaise, pallor and began to cough up blood-tinged sputum that was at first attributed to dental bleeding. She was admitted to the infirmary with hemoglobin = 4 mg/dL, hematocrit = 14%, platelets = 260,000, white blood cells = 8300, 74% segmented, 4% eosinophils, 19% lymphocytes and 3% monocytes. Radiographs of the chest revealed bilateral diffuse interstitial alveolar infiltrates. There was progressive worsening of cough and respiratory distress during the admission day, when she began to cough up large quantities of blood and hematuria was noted. There was rapid and progressive loss of renal function and massive lung hemorrhage. The antineutrophil cytoplasm antibody (ANCA test with antigen specificity for myeloperoxidase (anti-MPO was positive and the circulating anti-GBM showed an indeterminate result.

  18. Human immunodeficiency virus antibody test and seroprevalence in psychiatric patients.

    Science.gov (United States)

    Naber, D; Pajonk, F G; Perro, C; Löhmer, B

    1994-05-01

    Psychiatric inpatients are at risk for human immunodeficiency virus (HIV) infection. Investigations in the United States revealed seroprevalence rates of 5.5-8.9%. Therefore, inclusion of HIV antibody testing in routine laboratory screening is sometimes suggested. To investigate this issue for inpatients in the Department of Psychiatry, University of Munich, the incidence, reason for HIV testing and results were analyzed. Of 12,603 patients, hospitalized from 1985 to 1993, 4.9% (623 patients, 265 in risk groups) underwent the HIV test after informed consent. Thirty patients (4.8% of those tested) were found to be positive, but only in 5 cases (all of risk groups) was infection newly detected. Data indicate that, in psychiatry, HIV testing is reasonable only in patients in risk groups or if clinical variables suggest HIV infection.

  19. Performance of an oral fluid rapid HIV-1/2 test: experience from four CDC studies.

    Science.gov (United States)

    Delaney, Kevin P; Branson, Bernard M; Uniyal, Apurva; Kerndt, Peter R; Keenan, Patrick A; Jafa, Krishna; Gardner, Ann D; Jamieson, Denise J; Bulterys, Marc

    2006-08-01

    To evaluate the performance of a rapid HIV antibody test used with whole blood and oral fluid in settings where the test is likely to be used. In four separate studies, we compared the accuracy of the rapid test performed on whole blood and oral fluid specimens with the results of conventional HIV tests. Oral fluid and whole blood from persons of unknown HIV status recruited from clinics, labor and delivery units, and outreach venues were tested with the OraQuick Advance rapid HIV-1/2 antibody test. Sensitivity and specificity were compared with results of the enzyme immunoassay (EIA) and Western blot algorithm used by the study sites. OraQuick sensitivity was 99.7% with whole blood and 99.1% with oral fluid from 327 persons who were HIV antibody positive by the conventional algorithm. OraQuick specificity was 99.9% with whole blood and 99.6% with oral fluid from 12 010 HIV-negative persons; EIA specificity was 99.7%. A cluster of 16 false-positive oral fluid tests occurred in one study, in which specificity was lower (99.0%) than in the other three studies (99.6-99.8%). In diverse settings in four studies, the OraQuick test showed high sensitivity and specificity for HIV antibody in whole blood and oral fluid specimens. Slightly more false-positive and false-negative results occurred with oral fluid than with whole blood, but performance with both specimen types was similar to, or better than, that of conventional EIAs.

  20. 21 CFR 864.9175 - Automated blood grouping and antibody test system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Automated blood grouping and antibody test system... Manufacture Blood and Blood Products § 864.9175 Automated blood grouping and antibody test system. (a) Identification. An automated blood grouping and antibody test system is a device used to group erythrocytes (red...

  1. Comparison of the NIDS® rapid assay with ELISA methods in immunogenicity testing of two biotherapeutics.

    Science.gov (United States)

    Pan, Jing; Small, Thomas; Qin, Dujie; Li, Shawn; Wang, Li; Chen, Dave; Pauley, Cindy; Verch, Thorsten; Kaplanski, Catherine; Bakhtiar, Ray; Vallejo, Yli Remo; Yin, Ray

    2011-01-01

    Rapid lateral flow immunogenicity assays for the detection of anti-drug antibodies (ADAs) to two biotherapeutic antibodies, an anti-HER2 antibody and an anti-TNF-α antibody, were developed using ANP Technologies, Inc.'s proprietary Nano-Intelligent Detection System (NIDS®) and compared to their ELISA counterparts. Biotin and hapten-labeled drugs are incubated with the patient serum sample to allow ADA to form a bridge complex with each drug conjugate. The reaction mixture is then added to a test strip with an anti-hapten capture zone which captures the mixed bridge complex. The bridge-complexed biotinylated drug then reacts with streptavidin-labeled gold particles in situ. The signal developed at the capture zone, which is directly proportional to ADA in the sample, is then quantitatively measured with a handheld reader. The counterpart ELISAs were run using the same reagents. Dose-response, specificity/free drug depletion, and screening cut-point assays were performed using both methods. The rapid assays' performance compare very closely to their ELISA counterparts'. Both types of assays identified the same positive samples in screening a limited population of 50 normal serum samples for the anti-HER2 antibody. In the case of anti-TNF-α, both assays identified the same positive samples out of 50 normal and 20 rheumatoid arthritis patient serum samples but differed in the assessment of two others. The rapid assay correctly identified as negative an ELISA false positive sample, and correctly tested as positive an ELISA false negative sample. Positive results were verified with a specificity/free drug depletion assay. The NIDS® rapid immunogenicity assay offers distinct advantages over current methods in simplicity, low cost, and short time to result. More importantly, the method requires no sample dilution and no washing steps which can perturb fragile complexes formed by low-affinity ADAs. Thus, the assay can potentially detect ADAs with various affinities

  2. Rapid detection of respiratory viruses by shell vial culture and direct staining by using pooled and individual monoclonal antibodies.

    Science.gov (United States)

    Matthey, S; Nicholson, D; Ruhs, S; Alden, B; Knock, M; Schultz, K; Schmuecker, A

    1992-03-01

    The Bartels respiratory virus panel detection kit is an indirect fluorescent-antibody (IFA) method that uses pooled and individual antisera for tissue culture confirmation of seven respiratory viruses. We evaluated these reagents for detecting viral antigen in shell vial cultures and by direct staining of cells from respiratory specimens. The isolation from 254 specimens of respiratory viruses in shell vial cultures compared with standard tube cultures was highly sensitive (94%) and specific (97.3%). The numbers of viral isolates detected in three consecutive years of testing with shell vial cultures were 68 of 254 (26.8%), 101 of 381 (26.5%), and 122 of 430 (28.4%). IFA direct staining of all 1,065 specimens resulted in 183 (17.2) being uninterpretable because of inadequate numbers of cells or interfering fluorescence. The sensitivity and specificity of the interpretable IFA direct stains in comparison with shell vial cultures were 85.9 and 87.1%, respectively. For detection of 881 adequate specimens, Bartels respiratory syncytial virus IFA direct staining compared with an Ortho Diagnostics Systems direct fluorescent-antibody test for respiratory syncytial virus RSV was highly sensitive (95.5%) and specific (97%). Shell vial cultures combined with Bartels IFA reagents are a rapid alternative to standard tube cultures. Bartels IFA direct staining with individual antisera provides useful same-day screening of respiratory specimens, but the antiserum pool was not effective in screening for positive specimens because of excessive amounts of nonspecific fluorescence.

  3. A rapid diagnostic test for schistosomiasis mansoni

    Directory of Open Access Journals (Sweden)

    Clelia Christina Mello-Silva

    2013-12-01

    Full Text Available This article presents an improvement to the Kato-Katz (KK method, making it faster and more efficient for the visualisation of fertile eggs in stool samples. This modified KK method uses sodium acetate formalin as a fixative and reveals the intensity of infection in less than 1 h, reducing the diagnostic time without increasing the cost. This modified method may contribute to future epidemiological studies in both hospitals and the field due to its rapid and precise diagnostic, which allow for immediate treatment.

  4. Limited Applicability of Direct Fluorescent-Antibody Testing for Bordetella sp. and Legionella sp. Specimens for the Clinical Microbiology Laboratory▿

    OpenAIRE

    She, Rosemary C.; Billetdeaux, Erick; Phansalkar, Amit R.; Petti, Cathy A.

    2007-01-01

    The rapid diagnosis of infections with Bordetella and Legionella species is important for patient management. With observed increases in direct fluorescent-antibody (DFA) testing volumes, we retrospectively compared the performance characteristics of DFA testing to those of culture and PCR. For Bordetella sp., samples were classified as positive by DFA testing (184 [3%] of 6,195 samples) and culture (150 [2%] of 6,251 samples) significantly less often than by PCR (2,557 [10%] of 26,929 sample...

  5. Pretravel consultation: rapid dipstick test as a decision guidance for the application of tetanus booster vaccinations.

    Science.gov (United States)

    Paulke-Korinek, Maria; Rendi-Wagner, Pamela; Kundi, Michael; Tomann, Batya; Wiedermann, Ursula; Kollaritsch, Herwig

    2008-01-01

    When deciding whether to administer a tetanus vaccination--for international travel or injury--a subject's vaccination certificate should be investigated. As many people lack valid vaccination cards and are unable to recall their vaccination history, the Tetanos Quick Stick (TQS) test rapidly detects protective tetanus immunoglobulin IgG antibodies in whole blood, serum, or plasma. This immunochromatographic dipstick test yields a positive or negative result. Our study evaluates the effectiveness of the TQS test by comparing the binary TQS test results of 100 sera with the tetanus antibody levels as measured by the standardized enzyme-linked immunosorbent assay (ELISA) method. We used the TQS test to determine whether a person needed a tetanus booster vaccination. If the test showed a clearly visible line that was similar to the control line, the result was determined to be positive. All positive TQS test results had a concentration of IgG antibodies above 0.5 IU/mL as measured by ELISA, indicating that no booster vaccination was required. Similarly, in all cases with an antibody level below 0.1 IU/mL, where a vaccination would have been recommended based on the ELISA test result, the TQS test yielded a negative result. The positive predictive value and the specificity for the dipstick test were therefore 100%. The TQS test is a reliable, fast, and cost-effective means of identifying subjects with a preexisiting level of tetanus IgG antibodies above approximately 0.5 IU/mL. This can help to avoid unnecessary tetanus vaccinations in travel clinics, emergency departments, and practices of family doctors.

  6. Immunofluorescence tests for HIV antibody and their value as confirmatory tests.

    Science.gov (United States)

    van der Groen, G; Vercauteren, G; Piot, P

    1987-08-01

    The enzyme-linked immunosorbent assay (ELISA) is currently being used as a sensitive screening test for HIV antibody. The immunoblot assay (IBA) and indirect immunofluorescence (IF) techniques are two recommended confirmation tests for EIA-positive sera. An indirect IF test has been developed by various laboratories using acetone fixed mixtures of uninfected and HIV-infected cells, which facilitated the reading, since nonspecific reactions were easily differentiated from specific staining. Similar results have been obtained with H9-, CEM-, and HUT78-HIV-infected and uninfected cells. Anti-nuclear antibodies and auto-antibodies resulting in false-positive EIA results, could easily be differentiated by the IF test. Aspecific fluorescence can be removed by absorption of the specimens with non-infected cells. However, IF is not suitable for the screening of large series of specimens. IF is especially well suited for quantitative analysis of serum antibody levels. Whereas serum antibody titers rise initially after infection, they decrease as AIDS develops. Heat inactivation of sera did not affect reactivity in IF, in contrast to a high rate of false-positive results obtained with heat inactivated sera in some ELISAs. A well characterized serum from an AIDS patient can be used to perform IF in order to monitor HIV infection of susceptible cells. It has been claimed that titers of neutralizing antibodies significantly correlate with the levels of IF anti-HIV antibodies. An overall correlation of 99% between IF and IBA was reported by different laboratories, when HIV ELISA-reactive European and North American sera were tested. The concordance with IBA was 97% when HIV ELISA-reactive African sera were tested.(ABSTRACT TRUNCATED AT 250 WORDS)

  7. Development of an immunochromatographic strip test for rapid detection of melamine in raw milk, milk products, and animal feed

    Science.gov (United States)

    A simple, rapid and sensitive immunogold chromatographic strip test based on a monoclonal antibody was developed for the detection of melamine (MEL) residues in raw milk, milk products and animal feed. The limit of detection was estimated to be 0.05 µg/mL in raw milk, since the detection test line ...

  8. New monoclonal antibody-based test for Helicobacter pylori urease in gastric tissue.

    Science.gov (United States)

    Kim, Do Hyun; Kim, Ho Dong; Park, Hyeuk; Choi, Seung; Beom, Jae Won; Kim, Woo Jong; Park, Chang Kook; Lee, Young Jik; Park, Ju Young; Kim, Hyung Rag; Park, Chul; Joo, Young Eun; Jung, Young Do

    2016-01-01

    To evaluate a new monoclonal antibody for Helicobacter pylori urease in gastric tissue. A total of 107 volunteers were enrolled. All subjects underwent a (13)C-urea breath test and esophagogastroduodenoscopy. Gastric aspirates were analyzed for pH and ammonia. Six biopsy specimens in the gastric antrum and body were obtained for a rapid urease test and histology. The new monoclonal antibody-based H. pylori urease test (HPU) was performed to rapidly and qualitatively detect urease in two biopsy specimens. H. pylori infection was diagnosed in 73 subjects. The sensitivity and specificity of the HPU was 89% and 74%, respectively. The subjects were divided into two groups: one with true-positive and true-negative HPU results (n = 90) and the other with false-positive and false-negative HPU results (n = 17). Across all subjects, ammonia levels were 900.5 ± 646.7 and 604.3 ± 594.3 μmol/L (p > 0.05), and pH was 3.37 ± 1.64 and 2.82 ± 1.51 (p > 0.05). Sensitivity was higher in the presence of atrophic gastritis or intestinal metaplasia. HPU detected H. pylori in approximately 10 min. Gastric aspirate ammonia and pH levels did not affect the test results. Sensitivity was good in the presence of atrophic gastritis or intestinal metaplasia.

  9. Haploid technology allows for the efficient and rapid generation of homozygous antibody-accumulating transgenic tobacco plants.

    Science.gov (United States)

    Floss, Doreen M; Kumlehn, Jochen; Conrad, Udo; Saalbach, Isolde

    2009-09-01

    The large-scale production of plant-derived recombinant proteins requires the breeding of lines homozygous for the transgene(s). These can be selected by progeny testing over multiple sexual generations, but a more efficient means is to fix homozygosity in a single generation using doubled haploid technology. In this study, transgenic tobacco plants, hemizygous for both of the independently inherited genes encoding the light and heavy chains of the anti-human immunodeficiency virus monoclonal antibody 2F5, were used to establish embryogenic pollen cultures. The improved protocol employed in this study guaranteed a very high regeneration efficiency, with more than 50% of the regenerants being spontaneously doubled haploids. Hence, there was no requirement to chemically induce chromosome doubling to recover sufficient entirely homozygous recombinants. As expected, approximately 25% of the regenerants were homozygous for both transgenes. Thus, the employment of haploid technology allowed for the efficient and rapid generation of true-breeding tobacco lines accumulating functional immunoglobulins.

  10. Parallel rapid HIV testing in pregnant women at Tijuana General Hospital, Baja California, Mexico.

    Science.gov (United States)

    Viani, Rolando M; Araneta, Maria Rosario G; Spector, Stephen A

    2013-03-01

    The objectives of this study were to evaluate the performance of parallel rapid HIV testing and the presence of HIV-associated risk factors in pregnant women with unknown HIV status in Baja California, Mexico. Pregnant women attending the delivery unit or the prenatal clinic at Tijuana General Hospital had blood drawn for parallel rapid HIV testing with Determine™ HIV-1/2 and Uni-Gold™ Recombigen(®) HIV. The parallel rapid HIV test performance was compared to the enzyme immunoassay (EIA) and western blot. From September 2007 to July 2008, 1,383 (94%) of 1,464 women in labor and 1,992 (96%) of 2,075 women in prenatal care were enrolled. The HIV seroprevalence among women screened during labor (19/1,383, 1.37%, 95% CI: 0.85-2.18%) was significantly higher compared to those seeking prenatal care (5/1,992, 0.25%, 95% CI: 0.09-0.62%; ppositive by parallel rapid HIV testing 24 had a positive confirmatory western blot and one (0.03%) was confirmed as false positive. Additionally, two (0.06%) women had parallel rapid HIV discordant testing results; both tested negative by western blot. All women who tested negative by rapid testing had negative results on pooled EIA antibody testing. The overall sensitivity, specificity, and positive and negative predictive values of parallel rapid HIV testing were 100%, 99.9%, 96%, and 100%, respectively. These findings document a very high acceptance rate and an excellent performance of the parallel rapid HIV testing strategy during pregnancy.

  11. Development and testing of a rapid diagnostic test for bubonic and pneumonic plague.

    Science.gov (United States)

    Chanteau, Suzanne; Rahalison, Lila; Ralafiarisoa, Lalao; Foulon, Jeanine; Ratsitorahina, Mahery; Ratsifasoamanana, Lala; Carniel, Elisabeth; Nato, Farida

    2003-01-18

    Plague is often fatal without prompt and appropriate treatment. It affects mainly poor and remote populations. Late diagnosis is one of the major causes of human death and spread of the disease, since it limits the effectiveness of control measures. We aimed to develop and assess a rapid diagnostic test (RDT) for plague. We developed a test that used monoclonal antibodies to the F1 antigen of Yersinia pestis. Sensitivity and specificity were assessed with a range of bacterial cultures and clinical samples, and compared with findings from available ELISA and bacteriological tests for plague. Samples from patients thought to have plague were tested with the RDT in the laboratory and by health workers in 26 pilot sites in Madagascar. The RDT detected concentrations of F1 antigen as low as 0.5 ng/mL in up to 15 min, and had a shelf life of 21 days at 60 degrees C. Its sensitivity and specificity were both 100%. RDT detected 41.6% and 31% more positive clinical specimens than did bacteriological methods and ELISA, respectively. The agreement rate between tests done at remote centres and in the laboratory was 89.8%. With the combination of bacteriological methods and F1 ELISA as reference standard, the positive and negative predictive values of the RDT were 90.6% and 86.7%, respectively. Our RDT is a specific, sensitive, and reliable test that can easily be done by health workers at the patient's bedside, for the rapid diagnosis of pneumonic and bubonic plague. This test will be of key importance for the control of plague in endemic countries.

  12. Evaluation of a direct immunofluorescent antibody (difma test using Leishmania genus - specific monoclonal antibody in the routine diagnosis of cutaneous leishmaniasis

    Directory of Open Access Journals (Sweden)

    Martha E. Chico

    1995-06-01

    Full Text Available A direct immunofluorescent antibody (DIFMA test using a Leishmania genus- specific monoclonal antibody was evaluated in the routine diagnosis of cutaneous leishmaniasis (CL in Ecuador. This test was compared with the standard diagnostic techniques of scrapings, culture and histology. Diagnostic samples were taken from a total of 90 active dermal ulcers from patients from areas of Ecuador known to be endemic for cutaneous leishmaniasis. DIFMA was positive in all lesions. It was shown to be significantly superior to standard diagnostic methods either alone or in combination. The sensitivity of DIFMA did not diminish with chronicity of lesions. This test proved to be extremely useful in the routine diagnosis of CL because it is highly sensitive, is easy to use and produces rapid results.

  13. A comparison of rapid diagnostic testing (by plasmodium lactate ...

    African Journals Online (AJOL)

    Background: The World Health Organization (WHO) considers early and rapid diagnosis as one of the strategies to control malaria. This study compared the performance of Quantitative Buffy Coat (QBC) test and the Plasmodium lactate dehydrogenase (pLDH) rapid diagnostic test (RDT) with microscopy as the gold ...

  14. An alternative chemical redox method for the production of bispecific antibodies: implication in rapid detection of food borne pathogens.

    Directory of Open Access Journals (Sweden)

    Mohammad Owais

    Full Text Available Bi-functional antibodies with the ability to bind two unrelated epitopes have remarkable potential in diagnostic and bio-sensing applications. In the present study, bispecific antibodies that recognize human red blood cell (RBC and the food borne pathogen Listeria monocytogenes (L. monocytogenes were engineered. The procedure involves initial reduction of a mixture of anti-RBC and anti-Listeria antibodies followed by gradual re-oxidation of the reduced disulphides. This facilitates association of the separated antibody chains and formation of hybrid immunoglobulins with affinity for the L. monocytogenes and human RBC. The bispecific antibodies caused the agglutination of the RBCs only in the presence of L. monocytogenes cells. The agglutination process necessitated the specific presence of L. monocytogenes and the red colored clumps formed were readily visible with naked eyes. The RBC agglutination assay described here provides a remarkably simple approach for the rapid and highly specific screening of various pathogens in their biological niches.

  15. An ELISA-inhibition test using monoclonal antibody for the serology of leprosy

    NARCIS (Netherlands)

    Klatser, P. R.; de Wit, M. Y.; Kolk, A. H.

    1985-01-01

    In this study a mouse monoclonal antibody (47-9) is described, which recognized an epitope on the 36 kD protein antigen of M. leprae. The monoclonal antibody showed specificity for M. leprae. An ELISA-inhibition test based on the competitive inhibition by antibodies from human test sera of the

  16. Bifunctional recombinant fusion proteins for rapid detection of antibodies to both HIV-1 and HIV-2 in whole blood

    Directory of Open Access Journals (Sweden)

    Chaudhary Vijay K

    2006-09-01

    Full Text Available Abstract Background Availability of accurate diagnostic tests has been helpful in curtailing the spread of HIV infection. Among these, simple, point of care, inexpensive tests which require only a drop of blood from finger-prick and give reliable results within minutes are a must for expansion of testing services and for reaching mobile and marginalised populations. Such tests will not only be a boon for the infrastructure-starved developing and underdeveloped countries but will also be extremely useful in developed countries where post-testing compliance is a major problem. Our laboratory has been involved in developing reagents for heamagglutination-based rapid detection of antibodies to HIV in whole blood using recombinant molecules specific for either HIV-1 or HIV-2. Since it is not required of a screening test to differentially detect HIV and HIV-2, it would useful to create a single molecule capable of simultaneous detection of both HIV-1 and HIV-2 in a drop of blood. Results The present paper describes designing, high-level expression and large-scale purification of new molecules comprising recombinant anti-RBC Fab fused to immunodominant regions of envelope sequences from both gp41 of HIV-1 and gp36 of HIV-2. These immunodominant regions of HIV envelope contain cysteine residues, which make disulfide bond and can interfere with the assembly of light chain and heavy chain fragment to make Fab molecule in vitro. To circumvent this problem, a series of fusion proteins having different combinations of native and mutant envelope sequences were constructed, purified and evaluated for their efficacy in detecting antibodies to HIV-1 and HIV-2. A chimeric molecule comprising native envelope sequence of gp41 of HIV-1 and modified envelope sequence of gp36 of HIV-2 gave good production yield and also detected both HIV-1 and HIV-2 samples with high sensitivity and specificity. Conclusion The new bifunctional antibody fusion protein identified in

  17. Rapid single-tube method for small-scale affinity purification of polyclonal antibodies using HaloTag Technology.

    Science.gov (United States)

    Hata, Toshiyuki; Nakayama, Manabu

    2007-06-10

    Even in this era of advanced biotechniques, specific antibodies against a protein still prove to be powerful tools to study proteins and their functions. The polyclonal antisera obtained from the immunized rabbits, however, are not always pure, high affinity, antigen-specific polyclonal antibodies. With our new rapid HaloTag-based procedure, specific antibodies are obtained in just two, short steps: (1) simultaneous purification and covalent coupling of the antigen to Sepharose resin via the HaloTag and HaloLink reaction, and (2) affinity column purification of the polyclonal serum (10 microl). The combined antigen purification and coupling step requires only 1 h of room-temperature incubation, plus successive washing steps. Because different regions of an antigen can elicit the production of low affinity antibodies with relatively high cross-reactivity, the best way to produce high affinity antibodies against a protein of interest is to survey all antigenic determinants of that protein and identify the epitopes that result in the production of antibodies with a high affinity and specificity for that protein. Because our HaloTag procedure is quite rapid and simple, potential epitopes can be assessed with relatively little effort for their ability to elicit the production of highly specific antibodies.

  18. Rapid diagnosis of occult abscesses using sup 99m Tc-labeled monoclonal antibodies

    Energy Technology Data Exchange (ETDEWEB)

    Coons, T.A.; Rhodes, B.A. (RhoMed, Inc., Albuquerque, NM (USA)); Thakur, M.L. (Thomas Jefferson Univ., Philadelphia, PA (USA)); Marcus, C.S. (Harbor-UCLA Medical Center, Torrance, CA (USA)); Ballou, B. (Pittsburgh Univ., PA (USA))

    1991-01-01

    Acute infections, such as appendicitis and occult infections in AIDS patients, can be diagnosed within two hours by gamma scintigraphy after i.v. administration of {sup 99m}Tc labeled antibodies reactive with human granulocytes. The antibody, murine IgM anti-SSEA-1, is partially reduced using Sn(II) to expose and protect reactive sulfide groups. The antibody is then purified, stannous tartrate and stabilizers are added, and the mixture is lyophilized. To label, sodium pertechnetate is added. After a 15 minute incubation the tracer drug is injected. The rate of accumulation and degree of concentration at the site of infection is presumptively determinative of the severity of the infection. Acceptance criteria and tests for the {sup 99m}Tc labeled antibody product have been established and validated. Greater than 93% of the {sup 99m}Tc is firmly bound to the protein as determined by quantitative HPLC. Radiochemical impurities, colloidal {sup 99m}Tc and free pertechnetate are together less than 4% as determined by thin layer chromatography. The immunoreactive fraction, measured by binding to solid phase antigen, and affinity measured be ELISA, are unchanged by the {sup 99m}Tc-direct labeling process. Two hour blood clearance in rats is within 90% of the value of the {sup 125}I labeled analog. The immunoreactive fraction decreases less than 10% when incubated in human plasma for 24 hours. This method has been compared to other direct labeling methods, and found to give higher radiochemical yields. 5 figs.

  19. DARPA Antibody Technology Program Standardized Test Bed for Antibody Characterization: Characterization of an MS2 Human IgG Antibody Produced by AnaptysBio, Inc.

    Science.gov (United States)

    2016-02-01

    human IgG antibody produced by AnaptysBio DARPA ATP Standardized Test Bed for Antibody Characterization: Characterization of an MS2 Patricia E...Buckley, Patricia E.; Calm, Alena; Welsh, Heather; Thompson, Roy; Carney, James (ECBC); Warner, Candice; and Zacharko, Melody (Excet) 5d. PROJECT...corresponding aliquot was removed and placed in an ice bath . These samples were then tested for activity using ELISA. 2.7 ELISA ELISAs were

  20. False negative HIV antibody test in HIV infected children who receive early antiretroviral treatment in a resource-limited setting

    Directory of Open Access Journals (Sweden)

    Gerardo Alvarez-Uria

    2012-01-01

    Full Text Available With the implementation of 2010 World Health Organization guidelines, the number of infants from developing countries who will initiate antiretroviral therapy (ART will increase considerably. In this study we describe the HIV antibody tests of 14 HIV infected children who initiated ART at age less than one year in a rural setting of India. The HIV rapid test was negative in seven and indeterminate in two cases, whereas the HIV enzyme-linked immunosorbent assay (ELISA antibody test was negative in three and indeterminate in one case. In one child who had both negative HIV rapid test and ELISA initially, HIV serology turned positive after having a virological failure to ART, suggesting the possibility of utilizing HIV serology for monitoring ART effectiveness in children who experience HIV seroreversion. In conclusion, HIV seroreversion of children with early initiation of ART is common and should be considered for avoiding misdiagnosis of HIV infection. 

  1. Utility of point of care test devices for infectious disease testing of blood and oral fluid and application to rapid testing in the field

    Science.gov (United States)

    Lee, Stephen R.; Kardos, Keith W.; Yearwood, Graham D.; Guillon, Geraldine B.; Kurtz, Lisa A.; Mokkapati, Vijaya K.

    2008-04-01

    Rapid, point of care (POC) testing has been increasingly deployed as an aid in the diagnosis of infectious disease, due to its ability to deliver rapid, actionable results. In the case of HIV, a number of rapid test devices have been FDA approved and CLIA-waived in order to enable diagnosis of HIV infection outside of traditional laboratory settings. These settings include STD clinics, community outreach centers and mobile testing units, as well as identifying HIV infection among pregnant women and managing occupational exposure to infection. The OraQuick ® rapid test platform has been widely used to identify HIV in POC settings, due to its simplicity, ease of use and the ability to utilize oral fluid as an alternative specimen to blood. More recently, a rapid test for antibodies to hepatitis C virus (HCV) has been developed on the same test platform which uses serum, plasma, finger-stick blood, venous blood and oral fluid. Clinical testing using this POC test device has shown that performance is equivalent to state of the art, laboratory based tests. These devices may be suitable for rapid field testing of blood and other body fluids for the presence of infectious agents.

  2. Evaluation of current rapid HIV test algorithms in Rakai, Uganda.

    Science.gov (United States)

    Galiwango, Ronald M; Musoke, Richard; Lubyayi, Lawrence; Ssekubugu, Robert; Kalibbala, Sarah; Ssekweyama, Viola; Mirembe, Viola; Nakigozi, Gertrude; Reynolds, Steven J; Serwadda, David; Gray, Ronald H; Kigozi, Godfrey

    2013-09-01

    Rapid HIV tests are a crucial component of HIV diagnosis in resource limited settings. In Uganda, the Ministry of Health allows both serial and parallel HIV rapid testing using Determine, Stat-Pak and Uni-Gold. In serial testing, a non-reactive result on Determine ends testing. The performance of serial and parallel algorithms with Determine and Stat-Pak test kits was assessed. A cross-sectional diagnostic test accuracy evaluation using three rapid HIV test kits as per the recommended parallel test algorithm was followed by EIA-WB testing with estimates of the performance of serial testing algorithm. In 2520 participants tested by parallel rapid algorithms, 0.6% had weakly reactive result. Parallel testing had 99.7% sensitivity and 99.8% specificity. If Stat-Pak was used as the first screening test for a serial algorithm, the sensitivity was 99.6% and specificity was 99.7%. However, if Determine was used as the screening test, sensitivity was 97.3% and specificity was 99.9%. Serial testing with Stat-Pak as the initial screening test performed as well as parallel testing, but Determine was a less sensitive screen. Serial testing could be cost saving. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. Establishment of serological test to detect antibody against ferret coronavirus.

    Science.gov (United States)

    Minami, Shohei; Terada, Yutaka; Shimoda, Hiroshi; Takizawa, Masaki; Onuma, Mamoru; Ota, Akihiko; Ota, Yuichi; Akabane, Yoshihito; Tamukai, Kenichi; Watanabe, Keiichiro; Naganuma, Yumiko; Kanagawa, Eiichi; Nakamura, Kaneichi; Ohashi, Masanari; Takami, Yoshinori; Miwa, Yasutsugu; Tanoue, Tomoaki; Ohwaki, Masao; Ohta, Jouji; Une, Yumi; Maeda, Ken

    2016-07-01

    Since there is no available serological methods to detect antibodies to ferret coronavirus (FRCoV), an enzyme-linked immunosorbent assay (ELISA) using recombinant partial nucleocapsid (N) proteins of the ferret coronavirus (FRCoV) Yamaguchi-1 strain was developed to establish a serological method for detection of FRCoV infection. Many serum samples collected from ferrets recognized both a.a. 1-179 and a.a. 180-374 of the N protein, but two serum samples did not a.a. 180-374 of the N protein. This different reactivity was also confirmed by immunoblot analysis using the serum from the ferret.Therefore, the a.a. 1-179 of the N protein was used as an ELISA antigen. Serological test was carried out using sera or plasma of ferrets in Japan. Surprisingly, 89% ferrets in Japan had been infected with FRCoV. These results indicated that our established ELISA using a.a. 1-179 of the N protein is useful for detection of antibody to FRCoV for diagnosis and seroepidemiology of FRCoV infection.

  4. Prospective, multi-centre clinic-based evaluation of four rapid diagnostic tests for syphilis.

    Science.gov (United States)

    Mabey, D; Peeling, R W; Ballard, R; Benzaken, A S; Galbán, E; Changalucha, J; Everett, D; Balira, R; Fitzgerald, D; Joseph, P; Nerette, S; Li, J; Zheng, H

    2006-12-01

    To evaluate prospectively four rapid, point-of-care serological tests for syphilis in prenatal or high risk populations in four countries. Tests were performed on consecutive clinic attenders, using whole blood in the clinic, and whole blood and serum in the laboratory. The sensitivity and specificity of each test was evaluated, using a standard treponemal test (Treponema pallidum haemagglutination assay (TPHA) or fluorescent treponemal antibody, absorbed (FTA-ABS) as gold standard. Non-treponemal tests (rapid plasma reagin (RPR) or venereal diseases research laboratory (VDRL) tests) were also performed on all subjects at three sites. The specificity of each rapid test was >95% at each site. Sensitivities varied from 64-100% and, in most cases, were lower when whole blood was used rather than serum. Rapid serological tests for syphilis are an acceptable alternative to conventional laboratory tests. Since they do not require equipment or electricity, they could increase coverage of syphilis screening, and enable treatment to be given at the first clinic visit.

  5. Prospective, multi‐centre clinic‐based evaluation of four rapid diagnostic tests for syphilis

    Science.gov (United States)

    Mabey, D; Peeling, R W; Ballard, R; Benzaken, A S; Galbán, E; Changalucha, J; Everett, D; Balira, R; Fitzgerald, D; Joseph, P; Nerette, S; Li, J; Zheng, H

    2006-01-01

    Objectives To evaluate prospectively four rapid, point‐of‐care serological tests for syphilis in prenatal or high risk populations in four countries. Methods Tests were performed on consecutive clinic attenders, using whole blood in the clinic, and whole blood and serum in the laboratory. The sensitivity and specificity of each test was evaluated, using a standard treponemal test (Treponema pallidum haemagglutination assay (TPHA) or fluorescent treponemal antibody, absorbed (FTA‐ABS) as gold standard. Non‐treponemal tests (rapid plasma reagin (RPR) or venereal diseases research laboratory (VDRL) tests) were also performed on all subjects at three sites. Results The specificity of each rapid test was >95% at each site. Sensitivities varied from 64–100% and, in most cases, were lower when whole blood was used rather than serum. Conclusions Rapid serological tests for syphilis are an acceptable alternative to conventional laboratory tests. Since they do not require equipment or electricity, they could increase coverage of syphilis screening, and enable treatment to be given at the first clinic visit. PMID:17215274

  6. Evaluation Of Algorithms Of Anti- HIV Antibody Tests

    Directory of Open Access Journals (Sweden)

    Paranjape R.S

    1997-01-01

    Full Text Available Research question: Can alternate algorithms be used in place of conventional algorithm for epidemiological studies of HIV infection with less expenses? Objective: To compare the results of HIV sero- prevalence as determined by test algorithms combining three kits with conventional test algorithm. Study design: Cross â€" sectional. Participants: 282 truck drivers. Statistical analysis: Sensitivity and specificity analysis and predictive values. Results: Three different algorithms that do not include Western Blot (WB were compared with the conventional algorithm, in a truck driver population with 5.6% prevalence of HIV â€"I infection. Algorithms with one EIA (Genetic Systems or Biotest and a rapid test (immunocomb or with two EIAs showed 100% positive predictive value in relation to the conventional algorithm. Using an algorithm with EIA as screening test and a rapid test as a confirmatory test was 50 to 70% less expensive than the conventional algorithm per positive scrum sample. These algorithms obviate the interpretation of indeterminate results and also give differential diagnosis of HIV-2 infection. Alternate algorithms are ideally suited for community based control programme in developing countries. Application of these algorithms in population with low prevalence should also be studied in order to evaluate universal applicability.

  7. False-positive oral fluid rapid HIV tests--New York City, 2005-2008.

    Science.gov (United States)

    2008-06-20

    The New York City Department of Health and Mental Hygiene (NYC DOHMH) operates 10 sexually transmitted disease (STD) walk-in clinics offering various free services, including confidential or anonymous testing for human immunodeficiency virus (HIV). In January 2004, the STD clinics introduced on-site rapid HIV testing of finger-stick whole-blood specimens using the OraQuick(R) brand test (OraSure Technologies, Bethlehem, Pennsylvania). In March 2005, the clinics replaced finger-stick whole-blood testing with oral fluid testing with the OraQuick Advance Rapid HIV-1/2 Antibody Test. The clinics use Western blot confirmatory tests on serum to confirm all whole-blood or oral fluid reactive (i.e., preliminary positive) rapid tests. In late 2005, an unexpected increase in the number of false-positive oral fluid tests occurred, but the increase subsided after several months. In December 2005, while the cluster of false-positive oral fluid test results was being investigated, the NYC DOHMH Bureau of STD Control suspended oral fluid testing in the clinics for 3 weeks and replaced it with finger-stick whole-blood rapid testing, which produced no false-positive test results. On December 21, 2005, NYC DOHMH resumed oral fluid rapid testing but also introduced the use of immediate follow-up finger-stick whole-blood testing, using a second OraQuick test, after any reactive oral fluid test result. In late 2007, another larger increase in the incidence of false-positive oral fluid rapid test results was observed. The cause for the episodic increases in false-positive oral fluid tests has not yet been determined. NYC DOHMH has again suspended the use of oral fluid testing in STD clinics, and finger-stick whole-blood testing is the only rapid HIV test being used in this setting. These findings underscore the importance of confirming all reactive HIV tests, both from oral fluid and whole-blood specimens. In addition, the results suggest that the NYC DOHMH strategy of following up

  8. Testing techniques for mechanical characterization of rapidly solidified materials

    Science.gov (United States)

    Koch, C. C.

    1986-01-01

    Mechanical property testing techniques are reviewed for rapidly solidified materials. Mechanical testing of rapidly solidified materials is complicated by the fact that in most cases at least one dimension of the material is very small (less than 100 microns). For some geometries, i.e., powder or thin surface layers, microhardness is the only feasible mechanical test. The ribbon geometry which is obtained by the melt-spinning method, however, has been used for a variety of mechanical property measurements including elastic properties, tensile properties, fracture toughness, creep, and fatigue. These techniques are described with emphasis placed on the precautions required by the restricted geometry of rapidly solidified specimens.

  9. HybriFree: a robust and rapid method for the development of monoclonal antibodies from different host species.

    Science.gov (United States)

    Kivi, Gaily; Teesalu, Kaupo; Parik, Jüri; Kontkar, Elen; Ustav, Mart; Noodla, Liis; Ustav, Mart; Männik, Andres

    2016-01-08

    The production of recombinant monoclonal antibodies in mammalian cell culture is of high priority in research and medical fields. A critical step in this process is the isolation of the antigen-binding domain sequences of antibodies possessing the desired properties. Many different techniques have been described to achieve this goal, but all have shortcomings; most techniques have problems with robustness, are time-consuming and costly, or have complications in the transfer from isolation to production phase. Here, we report a novel HybriFree technology for the development of monoclonal antibodies from different species that is robust, rapid, inexpensive and flexible and can be used for the subsequent production of antibodies in mammalian cell factories. HybriFree technology is illustrated herein via detailed examples of isolating mouse, rabbit and chicken monoclonal antibody sequences from immunized animals. Starting from crude spleen samples, antigen capturing of specific B-cells is performed initially. cDNA of antibody variable domains is amplified from the captured cells and used a source material for simple and rapid restriction/ligation free cloning of expression vector library in order to produce scFv-Fc or intact IgG antibodies. The vectors can be directly used for screening purposes as well as for the subsequent production of the developed monoclonal antibodies in mammalian cell culture. The antibodies isolated by the method have been shown to be functional in different immunoassays, including ELISA, immunofluorescence and Western blot. In addition, we demonstrate that by using a modified method including a negative selection step, we can isolate specific antibodies targeting the desired epitope and eliminate antibodies directed to undesired off-targets. HybriFree can be used for the reliable development of monoclonal antibodies and their subsequent production in mammalian cells. This simple protocol requires neither the culturing of B-cells nor single

  10. Detection of chikungunya virus antigen by a novel rapid immunochromatographic test.

    Science.gov (United States)

    Okabayashi, Tamaki; Sasaki, Tadahiro; Masrinoul, Promsin; Chantawat, Nantarat; Yoksan, Sutee; Nitatpattana, Narong; Chusri, Sarunyou; Morales Vargas, Ronald E; Grandadam, Marc; Brey, Paul T; Soegijanto, Soegeng; Mulyantno, Kris Cahyo; Churrotin, Siti; Kotaki, Tomohiro; Faye, Oumar; Faye, Ousmane; Sow, Abdourahmane; Sall, Amadou Alpha; Puiprom, Orapim; Chaichana, Panjaporn; Kurosu, Takeshi; Kato, Seiji; Kosaka, Mieko; Ramasoota, Pongrama; Ikuta, Kazuyoshi

    2015-02-01

    Chikungunya fever is a mosquito-borne disease of key public health importance in tropical and subtropical countries. Although severe joint pain is the most distinguishing feature of chikungunya fever, diagnosis remains difficult because the symptoms of chikungunya fever are shared by many pathogens, including dengue fever. The present study aimed to develop a new immunochromatographic diagnosis test for the detection of chikungunya virus antigen in serum. Mice were immunized with isolates from patients with Thai chikungunya fever, East/Central/South African genotype, to produce mouse monoclonal antibodies against chikungunya virus. Using these monoclonal antibodies, a new diagnostic test was developed and evaluated for the detection of chikungunya virus. The newly developed diagnostic test reacted with not only the East/Central/South African genotype but also with the Asian and West African genotypes of chikungunya virus. Testing of sera from patients suspected to have chikungunya fever in Thailand (n = 50), Laos (n = 54), Indonesia (n = 2), and Senegal (n = 6) revealed sensitivity, specificity, and real-time PCR (RT-PCR) agreement values of 89.4%, 94.4%, and 91.1%, respectively. In our study using serial samples, a new diagnostic test showed high agreement with the RT-PCR within the first 5 days after onset. A rapid diagnostic test was developed using mouse monoclonal antibodies that react with chikungunya virus envelope proteins. The diagnostic accuracy of our test is clinically acceptable for chikungunya fever in the acute phase. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  11. Human antibody titers to Epstein-Barr Virus (EBV) gp350 correlate with neutralization of infectivity better than antibody titers to EBV gp42 using a rapid flow cytometry-based EBV neutralization assay.

    Science.gov (United States)

    Sashihara, Junji; Burbelo, Peter D; Savoldo, Barbara; Pierson, Theodore C; Cohen, Jeffrey I

    2009-09-01

    Measurement of neutralizing antibodies to Epstein-Barr virus (EBV) is important for evaluation of candidate vaccines. The current neutralization assay is based on antibody inhibition of EBV transformation of B cells and requires 6 weeks to perform. We developed a rapid, quantitative flow cytometry assay and show that neutralizing antibody titers measured by the new assay strongly correlate with antibody titers in the standard transformation-based assay. Antibodies to EBV gp350 and gp42 have been shown to block infection of B cells by EBV. Using new assays to quantify antibodies to these glycoproteins, we show for the first time that human plasma contains high titers of antibody to gp42; these titers correlate with neutralization of EBV infectivity or transformation. Furthermore, we show that antibody titers to EBV gp350 correlate more strongly with neutralization than antibody titers to gp42. These assays should be useful in accessing antibody responses to candidate EBV vaccines.

  12. Trichomonas spp. in pigeons: detection by OSOM Trichomonas Rapid Test.

    Science.gov (United States)

    Valek, Petr; Kunca, Tomas; Langrova, Iva; Hartlova, Helena; Brozova, Adela; Jankovska, Ivana; Kudrnacova, Marie; Sloup, Vladislav

    2013-12-01

    The efficacy of the OSOM Trichomonas Rapid Test (developed for rapid diagnosis of human Trichomonas vaginalis) in detection of Trichomonas spp. in pigeons (Columba livia) was investigated. Two oral cavity swabs were taken from 50 farm pigeons. Cultivation in Diamond Trichomonas medium was used as a reference method. According to a morphological determination, Trichomonas gallinae was the only protozoan found; however, no further molecular analysis was conducted. The OSOM Trichomonas test was positive in 39 oral swabs. In comparison with the cultivation method three samples were identified as false negative and one as false positive. Test specificity and sensitivity were established as 93% and 90%, respectively. Using Cohen's Kappa, the concordance between the two testing methods was found to be strong (kappa = 0.7506, 95% CI = 0.5162-0.9850). The OSOM Trichomonas test is not able to distinguish between Trichomonas species; however, results suggest that the test is suitable for the rapid detection of Trichomonas spp. infection in pigeons.

  13. Rapid Generation of In Vitro Multicellular Spheroids for the Study of Monoclonal Antibody Therapy

    Directory of Open Access Journals (Sweden)

    Yen T. Phung, Dario Barbone, V. Courtney Broaddus, Mitchell Ho

    2011-01-01

    Full Text Available Tumor microenvironments present significant barriers to penetration by antibodies and immunoconjugates and are difficult to study in vitro. Cells cultured as monolayers typically exhibit less resistance to therapy than those grown in vivo. Therefore, it is important to develop an alternative research model that better represents in vivo tumors. We have developed a protocol to produce multicellular spheroids, a simple and more relevant model of in vivo tumors that allows for further investigations of the microenvironmental effects on drug penetration and tumor cell killing. The protocol is used to produce in vitro three-dimensional tumor spheroids from established human cancer cell lines and primary cancer cells isolated from patients without the use of any extracellular components. To study the ability of tumor-targeting immunoconjugates to penetrate these tumor spheroids in vitro, we have used an immunotoxin targeting mesothelin, a surface protein expressed in malignant mesotheliomas. This method for producing consistent, reproducible 3D spheroids may allow for improved testing of novel monoclonal antibodies and other agents for their ability to penetrate solid tumors for cancer therapy.

  14. Community-based rapid oral human immunodeficiency virus testing for tuberculosis patients in Lima, Peru.

    Science.gov (United States)

    Nelson, Adrianne K; Caldas, Adolfo; Sebastian, Jose Luis; Muñoz, Maribel; Bonilla, Cesear; Yamanija, Jose; Jave, Oswaldo; Magan, Christina; Saldivar, Judith; Espiritu, Betty; Rosell, Gustavo; Bayona, Jaime; Shin, Sonya

    2012-09-01

    Among tuberculosis patients, timely diagnosis of human immunodeficiency virus (HIV) co-infection and early antiretroviral treatment are crucial, but are hampered by a myriad of individual and structural barriers. Community-based models to provide counseling and rapid HIV testing are few but offer promise. During November 2009-April 2010, community health workers offered and performed HIV counseling and testing by using the OraQuick Rapid HIV-1/2 Antibody Test to new tuberculosis cases in 22 Ministry of Health establishments and their household contacts (n = 130) in Lima, Peru. Refusal of HIV testing or study participation was low (4.7%). Intervention strengths included community-based approach with participant preference for testing site, use of a rapid, non-invasive test, and accompaniment to facilitate HIV care and family disclosure. We will expand the intervention under programmatic auspices for rapid community-based testing for new tuberculosis cases in high incidence establishments. Other potential target populations include contacts of HIV-positive persons and pregnant women.

  15. Rapid characterization of binding specificity and cross-reactivity of antibodies using recombinant human protein arrays.

    Science.gov (United States)

    Kijanka, Gregor; Ipcho, Simon; Baars, Sabine; Chen, Hong; Hadley, Katie; Beveridge, Allan; Gould, Edith; Murphy, Derek

    2009-01-30

    Antibodies are routinely used as research tools, in diagnostic assays and increasingly as therapeutics. Ideally, these applications require antibodies with high sensitivity and specificity; however, many commercially available antibodies are limited in their use as they cross-react with non-related proteins. Here we describe a novel method to characterize antibody specificity. Six commercially available monoclonal and polyclonal antibodies were screened on high-density protein arrays comprising of ~10,000 recombinant human proteins (Imagenes). Two of the six antibodies examined; anti-pICln and anti-GAPDH, bound exclusively to their target antigen and showed no cross-reactivity with non-related proteins. However, four of the antibodies, anti-HSP90, anti-HSA, anti-bFGF and anti-Ro52, showed strong cross-reactivity with other proteins on the array. Antibody-antigen interactions were readily confirmed using Western immunoblotting. In addition, the redundant nature of the protein array used, enabled us to define the epitopic region within HSP90 of the anti-HSP90 antibody, and identify possible shared epitopes in cross-reacting proteins. In conclusion, high-density protein array technology is a fast and effective means for determining the specificity of antibodies and can be used to further improve the accuracy of antibody applications.

  16. A retrospective evaluation of proficiency testing, and rapid HIV test ...

    African Journals Online (AJOL)

    Background: Proficiency testing (PT) has been implemented as a form of External Quality Assurance (EQA) by the National HIV Reference Laboratory in Kenya since 2007 in order to monitor and improve on the quality of HIV testing and counselling HTC services. Objective: To compare concordance between National HIV ...

  17. Clinical testing for neutralizing antibodies to interferon-? in multiple sclerosis

    OpenAIRE

    Creeke, Paul I.; Farrell, Rachel A.

    2013-01-01

    Biopharmaceuticals are drugs which are based on naturally occurring proteins (antibodies, receptors, cytokines, enzymes, toxins), nucleic acids (DNA, RNA) or attenuated microorganisms. Immunogenicity of these agents has been commonly described and refers to a specific antidrug antibody response. Such immunogenicity represents a major factor impairing the efficacy of biopharmaceuticals due to biopharmaceutical neutralization. Indeed, clinical experience has shown that induction of antidrug ant...

  18. 21 CFR 866.5785 - Anti-Saccharomyces cerevisiae (S. cerevisiae) antibody (ASCA) test systems.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Anti-Saccharomyces cerevisiae (S. cerevisiae... Immunological Test Systems § 866.5785 Anti-Saccharomyces cerevisiae (S. cerevisiae) antibody (ASCA) test systems. (a) Identification. The Anti-Saccharomyces cerevisiae (S. cerevisiae) antibody (ASCA) test system is...

  19. Indeterminate rapid HIV-1 test results among antenatal and postnatal mothers.

    Science.gov (United States)

    Matemo, D; Kinuthia, J; John, F; Chung, M; Farquhar, C; John-Stewart, G; Kiarie, J

    2009-11-01

    The sensitivity and specificity of rapid HIV-1 tests may be altered during pregnancy and postpartum. We conducted a study to determine the prevalence and correlates of false-positive Abbott Determine and false-negative Uni-Gold rapid HIV-1 test results among antenatal and postnatal mothers attending a primary care clinic in Nairobi, Kenya. Mothers were tested for HIV-1 using Abbott Determine and non-reactive results were considered HIV-1 antibody negative. Reactive samples by Determine were re-tested by Uni-Gold. Vironostika HIV-1 and Uni-FORM II Enzyme-linked immunosorbent assays were used to confirm samples that had positive Abbott Determine and negative Uni-Gold. Among 2311 women who accepted HIV-1 testing, 1238 (54%) were tested antenatally and 1073 (46%) were tested postnatally. Of tested women, 274 (12%) women were reactive by Abbott Determine and on retesting with Uni-Gold 30 (11%) had indeterminate results. The prevalence of indeterminate results was significantly higher in antenatal women than in postnatal women (2% versus 1%, P = 0.03). In conclusion, indeterminate rapid HIV-1 test results are more common in the antenatal period and appropriate safeguards to confirm HIV-1 infection status should be implemented in antenatal programmes.

  20. Development of microLIPS (Luciferase Immunoprecipitation Systems): a novel microfluidic assay for rapid serum antibody detection

    Science.gov (United States)

    Chandrangsu, Matt; Burbelo, Peter D.; Iadarola, Michael J.; Smith, Paul D.; Morgan, Nicole Y.

    2012-06-01

    There is considerable interest in the development of rapid, point-of-care antibody detection for the diagnosis of infectious and auto-immune diseases. In this paper, we present work on the development of a self-contained microfluidic format for the Luciferase Immunoprecipitation Systems (LIPS) assay. Whereas the majority of immunoassays for antigen-specific antibodies employ either bacteria- or yeast-expressed proteins and require the use of secondary antibodies, the LIPS technique uses a fusion protein comprised of a Renilla luciferase reporter and the antigen of interest produced via mammalian cell culture, ensuring the addition of mammalian post-translational modifications. Patient serum is mixed with the fusion protein and passed over immobilized Protein A/G; after washing, the only remaining luciferase-tagged antigens are those retained by specific antibodies. These can be quantitatively measured using chemiluminescence upon the introduction of coelenterazine. The assay has been successfully employed for a wide variety of diseases in a microwell format. We report on a recent demonstration of rapid HSV-2 diagnosis with the LIPS assay in a microfluidic format, using one microliter of serum and obtaining results in under ten minutes. We will also discuss recent progress on two fronts, both aimed at the deployment of this technology in the field: first, simplifying assay operation through the automation of flow control using power-free means; and second, efforts to increase signal levels, primarily through strategies to increase antibody binding capacity, in order to move towards portable battery powered electronics.

  1. Causes of false-positive HIV rapid diagnostic test results

    OpenAIRE

    Klarkowski, Derryck; O?Brien, Daniel P.; Shanks, Leslie; Singh, Kasha P.

    2014-01-01

    HIV rapid diagnostic tests have enabled widespread implementation of HIV programs in resource-limited settings. If the tests used in the diagnostic algorithm are susceptible to the same cause for false positivity, a false-positive diagnosis may result in devastating consequences. In resource-limited settings, the lack of routine confirmatory testing, compounded by incorrect interpretation of weak positive test lines and use of tie-breaker algorithms, can leave a false-positive diagnosis undet...

  2. Mortality among British Columbians testing for hepatitis C antibody.

    Science.gov (United States)

    Yu, Amanda; Spinelli, John J; Cook, Darrel A; Buxton, Jane A; Krajden, Mel

    2013-04-02

    Hepatitis C virus (HCV) infection is a major preventable and treatable cause of morbidity and mortality. The ability to link population based centralized laboratory HCV testing data with administrative databases provided a unique opportunity to compare mortality between HCV seronegative and seropositive individuals. Through the use of laboratory testing patterns and results, the objective of this study was to differentiate the viral effects of mortality due to HCV infection from risk behaviours/activities that are associated with acquisition of HCV infection. Serological testing data from the British Columbia (BC) Centre for Disease Control Public Health Microbiology and Reference Laboratory from 1992-2004 were linked to the BC Vital Statistics Agency death registry. Four groups of HCV testers were defined by their HCV antibody (anti-HCV) testing patterns: single non-reactive (SNR); serial multiple tested non-reactive (MNR); reactive at initial testing (REAC); and seroconverter (SERO) (previously seronegative followed by reactive, a marker for incident infection). Standardized mortality ratios (SMRs) were calculated to compare the relative risk of all cause and disease specific mortality to that of the BC population for each serological group. Time dependent Cox proportional hazard regression was used to compare hazard ratios (HRs) among HCV serological groups. All anti-HCV testers had higher SMRs than the BC population. Referent to the SNR group, the REAC group had higher risks for liver (HR: 9.62; 95% CI=8.55-10.87) and drug related mortality (HR: 13.70; 95% CI=11.76-16.13). Compared to the REAC group, the SERO group had a lower risk for liver (HR: 0.53; 95% CI=0.24-0.99), but a higher risk for drug related mortality (HR: 1.54; 95% CI=1.12-2.05). These findings confirm that individuals who test anti-HCV positive have increased mortality related to progressive liver disease, and that a substantial proportion of the mortality is attributable to drug use and risk

  3. Development and evaluation of a pseudovirus-luciferase assay for rapid and quantitative detection of neutralizing antibodies against enterovirus 71.

    Directory of Open Access Journals (Sweden)

    Xing Wu

    Full Text Available The level of neutralizing antibodies (NtAb induced by vaccine inoculation is an important endpoint to evaluate the efficacy of EV71 vaccine. In order to evaluate the efficacy of EV71 vaccine, here, we reported the development of a novel pseudovirus system expression firefly luciferase (PVLA for the quantitative measurement of NtAb. We first evaluated and validated the sensitivity and specificity of the PVLA method. A total of 326 serum samples from an epidemiological survey and 144 serum specimens from 3 clinical trials of EV71 vaccines were used, and the level of each specimen's neutralizing antibodies (NtAb was measured in parallel using both the conventional CPE-based and PVLA-based assay. Against the standard neutralization assay based on the inhibition of the cytopathic effect (CPE, the sensitivity and specificity of the PVLA method are 98% and 96%, respectively. Then, we tested the potential interference of NtAb against hepatitis A virus, Polio-I, Polio-II, and Polio-III standard antisera (WHO and goat anti-G10/CA16 serum, the PVLA based assay showed no cross-reactivity with NtAb against other specific sera. Importantly, unlike CPE based method, no live replication-competent EV71 is used during the measurement. Taken together, PVLA is a rapid and specific assay with higher sensitivity and accuracy. It could serve as a valuable tool in assessing the efficacy of EV71 vaccines in clinical trials and disease surveillance in epidemiology studies.

  4. Comparison of Rapid Malaria Test and Laboratory Microscopy ...

    African Journals Online (AJOL)

    Michael Horsfall

    ABSTRACT: Blood samples collected from 272 volunteers in two communities of Bayelsa State in the Niger. Delta area were investigated for falciparum malaria parasite using the rapid test based on the detection of soluble antigen and laboratory microscopy test. The data showed that out of the 272 samples collected, ...

  5. Field evaluation of a malaria rapid diagnostic test (ICT Pf ...

    African Journals Online (AJOL)

    Field evaluation of a malaria rapid diagnostic test (ICT Pf) ... province to determine the accuracy of the MRDT currently used in public sector clinics and hospitals. ... The positive predictive value of the test was 98.48 (99% CI 98.41 - 100%), and the negative predictive value was 99.52% (95% CI 96.47 – 100%). Conclusions.

  6. 21 CFR 866.5110 - Antiparietal antibody immunological test system.

    Science.gov (United States)

    2010-04-01

    ... absorbed by the body. The measurements aid in the diagnosis of vitamin B12 deficiency (or pernicious anemia... resulting when the body produces antibodies against its own tissues). (b) Classification. Class II...

  7. Evaluation of an inhouse rapid ELISA test for detection of giardia in domestic sheep (Ovis aries).

    Science.gov (United States)

    Wilson, Jolaine M; Hankenson, F Claire

    2010-11-01

    Sheep (Ovis aries) are increasingly used at our institution as models of human disease. Within the research environment, routine husbandry and handling of sheep has potential for transmission of zoonotic agents, including Giardia. The prevalence of Giardia in sheep may approach 68%. Classic diagnostic testing involves microscopic examination for fecal cysts or trophozoites; however, limitations of microscopy include time, labor, and potential false-negative results due to intermittent shedding. We wished to determine whether a commercial rapid ELISA used for Giardia detection in dogs and cats could be used in sheep. Fecal samples collected from sheep (n = 93) were tested with a combination of 6 methods: reference laboratory fecal flotation, reference laboratory ELISA, inhouse fecal flotation, and commercially available tests (enzyme immunoassay, direct fluorescence antibody assay, and rapid ELISA). Prevalence of Giardia infection in facility sheep was 11.8% (11 of 93 animals). Of the 11 samples considered positive, 3 were confirmed by multiple testing methods, and 5 were positive by microscopy alone. Inhouse fecal flotation for 8 samples was positive on only 1 of 2 consecutive testing days. The rapid ELISA test exhibited 0% sensitivity for sheep giardiasis. Overall, the examined methods had low sensitivities and low positive predictive values. Despite limitations, microscopic analysis of repeat fecal samples remained the most accurate diagnostic method for ovine giardiasis among the methods tested.

  8. Rapid assay for simultaneous detection and differentiation of immunoglobulin G antibodies to human immunodeficiency virus type 1 (HIV-1) group M, HIV-1 group O, and HIV-2.

    Science.gov (United States)

    Vallari, A S; Hickman, R K; Hackett, J R; Brennan, C A; Varitek, V A; Devare, S G

    1998-12-01

    A rapid immunodiagnostic test that detects and discriminates human immunodeficiency virus (HIV) infections on the basis of viral type, HIV type 1 (HIV-1) group M, HIV-1 group O, or HIV-2, was developed. The rapid assay for the detection of HIV (HIV rapid assay) was designed as an instrument-free chromatographic immunoassay that detects immunoglobulin G (IgG) antibodies to HIV. To assess the performance of the HIV rapid assay, 470 HIV-positive plasma samples were tested by PCR and/or Western blotting to confirm the genotype of the infecting virus. These samples were infected with strains that represented a wide variety of HIV strains including HIV-1 group M (subtypes A through G), HIV-1 group O, and HIV-2 (subtypes A and B). The results showed that the HIV genotype identity established by the rapid assay reliably (469 of 470 samples) correlates with the HIV genotype identity established by PCR or Western blotting. A total of 879 plasma samples were tested for IgG to HIV by a licensed enzyme immunoassay (EIA) (470 HIV-positive samples and 409 HIV-negative samples). When they were tested by the rapid assay, 469 samples were positive and 410 were negative (99.88% agreement). Twelve seroconversion panels were tested by both the rapid assay and a licensed EIA. For nine panels identical results were obtained by the two assays. For the remaining three panels, the rapid assay was positive one bleed later in comparison to the bleed at which the EIA was positive. One hundred three urine samples, including 93 urine samples from HIV-seropositive individuals and 10 urine samples from seronegative individuals, were tested by the rapid assay. Ninety-one of the ninety-three urine samples from HIV-seropositive individuals were found to be positive by the rapid assay. There were no false-positive results (98.05% agreement). Virus in all urine samples tested were typed as HIV-1 group M. These results suggest that a rapid assay based on the detection of IgG specific for selected

  9. Usefulness of Leukocyte Esterase Test Versus Rapid Strep Test for Diagnosis of Acute Strep Pharyngitis.

    Science.gov (United States)

    Nibhanipudi, Kumara V

    2015-01-01

    A study to compare the usage of throat swab testing for leukocyte esterase on a test strip(urine dip stick-multi stick) to rapid strep test for rapid diagnosis of Group A Beta hemolytic streptococci in cases of acute pharyngitis in children. The testing of throat swab for leukocyte esterase on test strip currently used for urine testing may be used to detect throat infection and might be as useful as rapid strep. All patients who come with a complaint of sore throat and fever were examined clinically for erythema of pharynx, tonsils and also for any exudates. Informed consent was obtained from the parents and assent from the subjects. 3 swabs were taken from pharyngo-tonsillar region, testing for culture, rapid strep & Leukocyte Esterase. Total number is 100. Cultures 9(+); for rapid strep== 84(-) and16 (+); For LE== 80(-) and 20(+) From data configuration Rapid Strep versus LE test don't seem to be a random (independent) assignment but extremely aligned. The Statistical results show rapid and LE show very agreeable results. Calculated Value of Chi Squared Exceeds Tabulated under 1 Degree Of Freedom (Pthroat swab is as useful as rapid strep test for rapid diagnosis of strep pharyngitis on test strip currently used for urine dip stick causing acute pharyngitis in children.

  10. Usefulness of Leukocyte Esterase Test Versus Rapid Strep Test for Diagnosis of Acute Strep Pharyngitis

    Directory of Open Access Journals (Sweden)

    Kumara V. Nibhanipudi MD

    2015-08-01

    Full Text Available Objective: A study to compare the usage of throat swab testing for leukocyte esterase on a test strip(urine dip stick-multi stick to rapid strep test for rapid diagnosis of Group A Beta hemolytic streptococci in cases of acute pharyngitis in children. Hypothesis: The testing of throat swab for leukocyte esterase on test strip currently used for urine testing may be used to detect throat infection and might be as useful as rapid strep. Methods: All patients who come with a complaint of sore throat and fever were examined clinically for erythema of pharynx, tonsils and also for any exudates. Informed consent was obtained from the parents and assent from the subjects. 3 swabs were taken from pharyngo-tonsillar region, testing for culture, rapid strep & Leukocyte Esterase. Results: Total number is 100. Cultures 9(+; for rapid strep== 84(- and16 (+; For LE== 80(- and 20(+ Statistics: From data configuration Rapid Strep versus LE test don’t seem to be a random (independent assignment but extremely aligned. The Statistical results show rapid and LE show very agreeable results. Calculated Value of Chi Squared Exceeds Tabulated under 1 Degree Of Freedom (P<.0.0001 reject Null Hypothesis and Conclude Alternative Conclusions: Leukocyte esterase on throat swab is as useful as rapid strep test for rapid diagnosis of strep pharyngitis on test strip currently used for urine dip stick causing acute pharyngitis in children.

  11. Application of a human monoclonal antibody in a rapid competitive anti-HIV ELISA.

    Science.gov (United States)

    Döpel, S H; Porstmann, T; Grunow, R; Jungbauer, A; Von Baehr, R

    1989-01-17

    The ELISA is the established screening technique for the detection of antibodies directed against HIV. The first generation assays, mostly based on the sandwich principle, employed purified virus from cell culture and gave both false-positive and false-negative results. Sandwich-type assays preferentially detect IgG antibodies, require a high serum dilution and are two-step procedures. In order to detect an immune response as early as possible after infection anti-HIV antibodies of the IgM class should also be measured. To this end a competitive ELISA has been developed using a solid phase-adsorbed recombinant HIV envelope protein and an enzyme-labelled human monoclonal antibody. This detects both IgM and IgG antibodies, the results are available within 1 h and a serum predilution is not necessary.

  12. A Rapid Detection Method of Brucella with Quantum Dots and Magnetic Beads Conjugated with Different Polyclonal Antibodies

    Science.gov (United States)

    Song, Dandan; Qu, Xiaofeng; Liu, Yushen; Li, Li; Yin, Dehui; Li, Juan; Xu, Kun; Xie, Renguo; Zhai, Yue; Zhang, Huiwen; Bao, Hao; Zhao, Chao; Wang, Juan; Song, Xiuling; Song, Wenzhi

    2017-03-01

    Brucella spp. are facultative intracellular bacteria that cause zoonotic disease of brucellosis worldwide. Traditional methods for detection of Brucella spp. take 48-72 h that does not meet the need of rapid detection. Herein, a new rapid detection method of Brucella was developed based on polyclonal antibody-conjugating quantum dots and antibody-modified magnetic beads. First, polyclonal antibodies IgG and IgY were prepared and then the antibody conjugated with quantum dots (QDs) and immunomagnetic beads (IMB), respectively, which were activated by N-(3-dimethylaminopropyl)- N'-ethylcar-bodiimide hydrochloride (EDC) and N-hydroxysuccinimide (NHS) to form probes. We used the IMB probe to separate the Brucella and labeled by the QD probe, and then detected the fluorescence intensity with a fluorescence spectrometer. The detection method takes 105 min with a limit of detection of 103 CFU/mL and ranges from 10 to 105 CFU/mL ( R 2 = 0.9983), and it can be well used in real samples.

  13. Rapid detection of avian influenza A virus by immunochromatographic test using a novel fluorescent dye.

    Science.gov (United States)

    Yeo, Seon-Ju; Cuc, Bui Thi; Kim, Soon-Ai; Kim, Do Thi Hoang; Bao, Duong Tuan; Tien, Trinh Thi Thuy; Anh, Nguyen Thi Viet; Choi, Do-Young; Chong, Chom-Kyu; Kim, Hak Sung; Park, Hyun

    2017-08-15

    Sensitive and rapid diagnostic systems for avian influenza (AI) virus are required to screen large numbers of samples during a disease outbreak and to prevent the spread of infection. In this study, we employed a novel fluorescent dye for the rapid and sensitive recognition of AI virus. The styrylpyridine phosphor derivative was synthesized by adding allyl bromide as a stable linker and covalently immobilizing it on latex beads with antibodies generating the unique Red dye 53-based fluorescent probe. The performance of the innovative rapid fluorescent immnunochromatographic test (FICT) employing Red dye 53 in detecting the AI virus (A/H5N3) was 4-fold and 16-fold higher than that of Europium-based FICT and the rapid diagnostic test (RDT), respectively. In clinical studies, the presence of human nasopharyngeal specimens did not alter the performance of Red dye 53-linked FICT for the detection of H7N1 virus. Furthermore, in influenza A virus-infected human nasopharyngeal specimens, the sensitivity of the Red dye 53-based assay and RDT was 88.89% (8/9) and 55.56% (5/9) relative to rRT-PCR, respectively. The photostability of Red dye 53 was higher than that of fluorescein isothiocyanate (FITC), showing a stronger fluorescent signal persisting up to 8min under UV. The Red dye 53 could therefore be a potential probe for rapid fluorescent diagnostic systems that can recognize AI virus in clinical specimens. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Comparison of five assays for antibody to varicella-zoster virus and the fluorescent-antibody-to-membrane-antigen test.

    OpenAIRE

    Larussa, P; Steinberg, S; Waithe, E; Hanna, B; Holzman, R

    1987-01-01

    Three commercially available assays (the Varicelisa Test Kit [Whittaker M.A. Bioproducts, Walkersville, Md.], the VZV Indirect Fluorescent-Antibody Test [Electro-Nucleonics, Inc., Columbia, Md.], and the Litton VZV Bio-EnzaBead Screen Kit [Litton Bionetics, Inc., Charleston, S.C.]) and two enzyme-linked immunosorbent assays used in our laboratory, one using a membrane-associated antigen and the other using a soluble antigen dotted on nitrocellulose paper, were compared with a varicella-zoster...

  15. Risk factors for feline immunodeficiency virus antibody test status in Cats Protection adoption centres (2004).

    Science.gov (United States)

    Murray, Jane K; Roberts, Margaret A; Skillings, Elizabeth; Morrow, Lisa D; Gruffydd-Jones, Timothy J

    2009-06-01

    A study was carried out to determine the prevalence of feline immunodeficiency virus (FIV) within a population of cats entering 10 UK adoption centres run by Cats Protection. All cats entering the adoption centres during 2004 were tested for FIV using a rapid enzyme immunoassay antibody test. The overall prevalence of positive test results was 3.1% (95% confidence intervals (CI) 2.7-3.5%), whilst the prevalence at different adoption centres varied from 0.8% (95% CI 0.1-1.5%) to 6.7% (95% CI 4.9-8.5%). Results of the multivariable logistic regression analysis showed that male cats, stray/feral cats and cats in poor health were at a greater risk of testing positive for FIV than female cats, cats that were relinquished by an owner and cats that were in good/fair health, respectively. No evidence was found for an association between neuter status and FIV test results. This study may help to identify cats that are relinquished to rescue centres with an increased risk of FIV for routine FIV testing.

  16. Usefulness of Leukocyte Esterase Test Versus Rapid Strep Test for Diagnosis of Acute Strep Pharyngitis

    OpenAIRE

    Kumara V. Nibhanipudi MD

    2015-01-01

    Objective: A study to compare the usage of throat swab testing for leukocyte esterase on a test strip(urine dip stick-multi stick) to rapid strep test for rapid diagnosis of Group A Beta hemolytic streptococci in cases of acute pharyngitis in children. Hypothesis: The testing of throat swab for leukocyte esterase on test strip currently used for urine testing may be used to detect throat infection and might be as useful as rapid strep. Methods: All patients who come with a complaint of sore t...

  17. Rapid Color Test Identification System for Screening of Counterfeit Fluoroquinolone

    Directory of Open Access Journals (Sweden)

    B. K. Singh

    2009-01-01

    Full Text Available The protocol of rapid identification system consists of three chemical color reactions; two group tests for fluoroquinolone class and a compound specific test each for norfloxacin, ciprofloxacin, gatifloxacin, ofloxacin, levofloxacin and sparfloxacin. The group color reactions are based on (a Oxidizing behavior of quinolone and (b Fluorine functional groups, both of which are characteristic of fluoroquinolone class. The compound specific color reactions are developed taking into consideration unique chemical behavior of each compound. The proposed chemical color tests have high selectivity⁄specificity, are ideal for screening purpose. The color of each test was defined by two standard color systems namely CIE lab and Munsell color. A suspected counterfeit tablet of any of the above mentioned drugs can be identified within 10-15 min using this rapid identification system.

  18. Comparison of Reliability of Rapid Diagonostic Test to Microscopy in ...

    African Journals Online (AJOL)

    Comparison of Reliability of Rapid Diagonostic Test to Microscopy in the Diagnosis of Malaria at Gulu Regional Referral Hospital. ... East African Medical Journal ... Conclusion: RDTs can be used to quickly confirm the clinical diagnosis of malaria to reduce irrational use of anti-malarials when microscopy is not available ...

  19. Simple and rapid field tests for brucellosis in livestock

    NARCIS (Netherlands)

    Abdoel, Theresia; Dias, Isabel Travassos; Cardoso, Regina; Smits, Henk L.

    2008-01-01

    Four simple and rapid field tests for the serodiagnosis of brucellosis in cattle, goat, sheep and swine were developed. The performance of the assays was investigated using serum samples collected in Portugal from animals originating from herds with a defined sanitary status with respect to the

  20. DARPA Antibody Technology Program. Standardized Test Bed for Antibody Characterization: Characterization of an MS2 ScFv Antibody Produced by Illumina

    Science.gov (United States)

    2016-08-01

    Proving Ground , MD) has provided specific technical support on immune reagents and defined the government-supplied antibody–antigen pairs. The goal of this... resonance (SPR) thermostability testing. A Tm above 70 °C predicts that the percent of antibody activity after the thermal stress test will remain above... resonance angle (SPR angle) changes, and this SPR angle shift provides information on the protein adsorption kinetics on the surface. The software can

  1. Rapid enzymatic test for phenotypic HIV protease drug resistance

    OpenAIRE

    Hoffmann, D.; Assfalg-Machleidt, Irmgard; Nitschko, H; Helm, K. von der; Koszinowski, U.; Machleidt, Werner

    2003-01-01

    A phenotypic resistance test based on recombinant expression of the active HIV protease in E. coli from patient blood samples was developed. The protease is purified in a rapid onestep procedure as active enzyme and tested for inhibition by five selected synthetic inhibitors (amprenavir, indinavir, nelfinavir, ritonavir, and saquinavir) used presently for chemotherapy of HIVinfected patients. The HPLC system used in a previous approach was replaced by a continuous fluorogenic assay suitable f...

  2. Method and apparatus using selected superparamagnetic labels for rapid quantification of immunochromatographic tests

    Directory of Open Access Journals (Sweden)

    Mika PA Laitinen

    2009-04-01

    Full Text Available Mika PA Laitinen1, Jari Salmela2, Leona Gilbert1, Risto Kaivola1, Topi Tikkala2, Christian Oker-Blom1, Jukka Pekola3, Matti Vuento11Department of Biological and Environmental Science; 2Department of Physics, University of Jyväskylä, Jyväskylä, Finland; 3Low Temperature Laboratory, Helsinki University of Technology, Helsinki, FinlandAbstract: A rapid method and instrumentation for quantification of immunochromatographic tests (ICT are described. The principle and performance of the method was demonstrated by measuring the levels of human chorionic gonadotropin (hCG present in urine. The test format was a sandwich assay using two distinct monoclonal antibodies directed against hCG. The first anti-hCG antibody was labeled with superparamagnetic particles whereas the second was immobilized as a narrow detection zone on a porous membrane. The human urine sample was mixed with superparamagnetic particles coated with the first anti-hCG antibody, and the mixture was allowed to migrate past the detection zone containing the second anti-hCG antibody. Capillary forces facilitated migration of the immune complexes along the porous membrane. The amount of superparamagnetic particle-labelled monoclonal anti-hCG bound to the detection zone was directly proportional to the amount of hCG present in the sample as detected by measuring magnetization in the detector coil. The method had a practical detection limit of 20 U/l (54 nM of hCG per 5 μl of human urine and a linear range of three decades from 20 U/l to 10 000 U/l. In addition, the analysis was completed within less than 10 minutes. Thus, the test format should be suitable for fast detection and monitoring of a large variety of clinically important parameters and analytes.Keywords: affinity, biosensor, hCG, immunochromatography, magnetization, superparamagnetic

  3. Testing for Antibodies to Brucella abortus in Milk From Consumers ...

    African Journals Online (AJOL)

    Over 85% of all milk sales on Kenya pass through informal channels. The extent of the risk posed by the sale of this raw milk to human health in respect to brucellosis is unknown. This paper presents the results of a study on the occurrence of antibodies to Brucella abortus in milk from households consuming raw ...

  4. Reliability of the INSTI® rapid test for the diagnosis of HIV-1 non-B subtypes and recombinant variants.

    Science.gov (United States)

    Goupil de Bouillé, Jeanne; Le Moal, Gwénaël; Hocqueloux, Laurent; Guigon, Aurélie; Plainchamp, David; Giraudeau, Geneviève; Theillay, Aurélie; Languille, Anne; Bélec, Laurent; Prazuck, Thierry

    2016-01-01

    Data regarding the efficacy of Rapid HIV tests (RHTs) in detecting non-B subtype HIV-1 are limited. We evaluated the sensitivity of the INSTI® test for the detection of HIV-1 antibodies for the diagnosis of HIV-1 non-B subtypes and recombinant variants. We identified adults with HIV-1 infection due to non-B subtypes and recombinant variants. The participants were re-tested with INSTI® test. We included 258 patients. Overall, the INSTI® test sensitivity was 98.4% (95%CI: 96.9-99.9%). For the major CRF_02AG subtype, the sensitivity was 99.0% (95%CI: 97.1-100%). The HIV INSTI® test is reliable for the detection of various non-B HIV-1 antibodies. © 2015 Wiley Periodicals, Inc.

  5. Causes of false-positive HIV rapid diagnostic test results.

    Science.gov (United States)

    Klarkowski, Derryck; O'Brien, Daniel P; Shanks, Leslie; Singh, Kasha P

    2014-01-01

    HIV rapid diagnostic tests have enabled widespread implementation of HIV programs in resource-limited settings. If the tests used in the diagnostic algorithm are susceptible to the same cause for false positivity, a false-positive diagnosis may result in devastating consequences. In resource-limited settings, the lack of routine confirmatory testing, compounded by incorrect interpretation of weak positive test lines and use of tie-breaker algorithms, can leave a false-positive diagnosis undetected. We propose that heightened CD5+ and early B-lymphocyte response polyclonal cross-reactivity are a major cause of HIV false positivity in certain settings; thus, test performance may vary significantly in different geographical areas and populations. There is an urgent need for policy makers to recognize that HIV rapid diagnostic tests are screening tests and mandate confirmatory testing before reporting an HIV-positive result. In addition, weak positive results should not be recognized as valid except in the screening of blood donors.

  6. Immunoblotting as a confirmatory test for antimitochondrial antibodies in primary biliary cirrhosis.

    Science.gov (United States)

    Provenzano, G; Diquattro, O; Craxì, A; Almasio, P; Pinzello, G; Marino, L; Fiorentino, G; Rinaldi, F; Pagliaro, L

    1993-01-01

    Primary biliary cirrhosis is characterised by the presence of antimitochondrial antibodies which are directed against components of mitochondrial dehydrogenase complexes. The specificity of antimitochondrial antibodies for primary biliary cirrhosis as detected by immunoblotting was investigated. Commercially available preparations of pyruvate and oxo-glutarate dehydrogenases and beef-heart mitochondria were used as source of antigens. Sera from 47 primary biliary cirrhosis patients (46 of whom were antimitochondrial antibody positive by immunofluorescence), 16 non-primary biliary cirrhosis patients (antimitochondrial antibody positive by immunofluorescence), 23 liver-kidney microsomal antibody positive chronic active hepatitis patients, and 32 patients with connective tissue diseases were examined. Of the 47 subjects with primary biliary cirrhosis, 43 (91%) and 13 (28%) tested positive by immunoblotting for pyruvate and oxo-glutarate dehydrogenase, respectively. Only three primary biliary cirrhosis patients were negative for both antigens, including the only one shown to be antimitochondrial antibody negative by immunofluorescence. The other two patients were positive by immunoblotting with beef-heart mitochondria. In contrast, only three of 16 (19%) non-primary biliary cirrhosis patients who were antimitochondrial antibody positive by immunofluorescence tested positive by immunoblotting (for both pyruvate dehydrogenase and beef-heart mitochondria). None of the 23 liver-kidney microsomal antibody positive and the 32 patients with rheumatic diseases were positive by immunoblotting with any antigen. Our data show that immunoblotting with commercially available oxo-acid dehydrogenases is a reproducible method for the detection of antimitochondrial antibodies highly specific for primary biliary cirrhosis. Images p546-a PMID:8491404

  7. Evaluation of rapid tests for anti-HIV detection in Brazil.

    Science.gov (United States)

    Ferreira Junior, Orlando C; Ferreira, Cristine; Riedel, Maristela; Widolin, Marcya Regina Visinoni; Barbosa-Júnior, Aristides

    2005-10-01

    This assessment in Brazil was to evaluate the performance of commercially available HIV rapid test (RT) against the gold standard testing and to establish a highly sensitive and specific RT algorithm for HIV diagnosis. A prospective, anonymous and unlinked study. An evaluation of seven commercially available RT to compare their performance against the gold standard tests for Brazil. This includes two competing enzyme immunoassays plus a Western blot for confirmation. After informed consent, whole blood samples were collected from volunteers in voluntary counselling and testing sites (n = 400), antenatal clinics (n = 500) and from HIV-positive controls in AIDS treatment centres (n = 200). Two seroconversion panels, one HIV-1 subtype (B, B', C and F) panel and an operational assay performance evaluation were also part of the study parameters. For the seven RT the clinical sensitivity ranged from 97.74 to 100% and clinical specificity from 99.43 to 100%. However, only four RT were considered acceptable after full evaluation. The two EIA had a clinical sensitivity of 100% and clinical specificity of 99.32 and 99.66%. Two RT had the same performance on the seroconversions panels as the EIA. The operational assay performance evaluation for the RT indicated that Hexagon and Capillus could not be classified as simple assays. We have provided evidence that RT assays can perform equally or better than EIA for the detection of HIV antibodies. The simplicity and rapidity of the RT warrants its utilization in an algorithm for a rapid diagnosis of HIV infection.

  8. Improving prescribing practices with rapid diagnostic tests (RDTs)

    DEFF Research Database (Denmark)

    Burchett, Helen E D; Leurent, Baptiste; Baiden, Frank

    2017-01-01

    OBJECTIVES: The overuse of antimalarial drugs is widespread. Effective methods to improve prescribing practice remain unclear. We evaluated the impact of 10 interventions that introduced rapid diagnostic tests for malaria (mRDTs) on the use of tests and adherence to results in different contexts...... packages, supervision, supplies and community sensitisation. OUTCOME MEASURES: Analysis explored variation in: (1) uptake of mRDTs (% febrile patients tested); (2) provider adherence to positive mRDTs (% Plasmodium falciparum positive prescribed/given Artemisinin Combination Treatment); (3) provider...

  9. Evaluation of simple rapid HIV assays and development of national rapid HIV test algorithms in Dar es Salaam, Tanzania

    Directory of Open Access Journals (Sweden)

    Mbwana Judica

    2009-02-01

    Full Text Available Abstract Background Suitable algorithms based on a combination of two or more simple rapid HIV assays have been shown to have a diagnostic accuracy comparable to double enzyme-linked immunosorbent assay (ELISA or double ELISA with Western Blot strategies. The aims of this study were to evaluate the performance of five simple rapid HIV assays using whole blood samples from HIV-infected patients, pregnant women, voluntary counseling and testing attendees and blood donors, and to formulate an alternative confirmatory strategy based on rapid HIV testing algorithms suitable for use in Tanzania. Methods Five rapid HIV assays: Determine™ HIV-1/2 (Inverness Medical, SD Bioline HIV 1/2 3.0 (Standard Diagnostics Inc., First Response HIV Card 1–2.0 (PMC Medical India Pvt Ltd, HIV1/2 Stat-Pak Dipstick (Chembio Diagnostic System, Inc and Uni-Gold™ HIV-1/2 (Trinity Biotech were evaluated between June and September 2006 using 1433 whole blood samples from hospital patients, pregnant women, voluntary counseling and testing attendees and blood donors. All samples that were reactive on all or any of the five rapid assays and 10% of non-reactive samples were tested on a confirmatory Inno-Lia HIV I/II immunoblot assay (Immunogenetics. Results Three hundred and ninety samples were confirmed HIV-1 antibody positive, while 1043 were HIV negative. The sensitivity at initial testing of Determine, SD Bioline and Uni-Gold™ was 100% (95% CI; 99.1–100 while First Response and Stat-Pak had sensitivity of 99.5% (95% CI; 98.2–99.9 and 97.7% (95% CI; 95.7–98.9, respectively, which increased to 100% (95% CI; 99.1–100 on repeat testing. The initial specificity of the Uni-Gold™ assay was 100% (95% CI; 99.6–100 while specificities were 99.6% (95% CI; 99–99.9, 99.4% (95% CI; 98.8–99.7, 99.6% (95% CI; 99–99.9 and 99.8% (95% CI; 99.3–99.9 for Determine, SD Bioline, First Response and Stat-Pak assays, respectively. There was no any sample which was

  10. Rapid Isolation of Monoclonal Antibodies Specific for Cell Surface Differentiation Antigens

    Science.gov (United States)

    Barclay, Stephen L.; Smith, Alan M.

    1986-06-01

    Two immunization procedures were compared for their ability to yield monoclonal antibodies that react with plasma membrane-bound differentiation antigens of Dictyostelium. In the first method, hybridomas prepared from BALB/c mice immunized with aggregating amoebae produced monoclonal antibodies that recognized antigens present on both growing and aggregating Dictyostelium amoebae. None of the monoclonal antibodies reacted with only the injected aggregation-stage cell type. In contrast, monoclonal antibodies that reacted with differentiation antigens were easily obtained by primary immunization of BALB/c mice with living aggregation-stage cells, followed by secondary immunization with a preparation of plasma membrane from aggregating cells or intact aggregating cells mixed with polyclonal BALB/c antiserum raised against undifferentiated cells. By this method, approximately 20% of all anti-Dictyostelium monoclonal antibodies obtained in a fusion are specific for differentiation antigens. The properties and developmental regulation of several of these antigens are described. The possible uses of this immunological method to detect unique determinants on other kinds of cells and the likely immune mechanisms that make it successful are discussed.

  11. A Lateral Flow Protein Microarray for Rapid and Sensitive Antibody Assays

    Directory of Open Access Journals (Sweden)

    Helene Andersson-Svahn

    2011-11-01

    Full Text Available Protein microarrays are useful tools for highly multiplexed determination of presence or levels of clinically relevant biomarkers in human tissues and biofluids. However, such tools have thus far been restricted to laboratory environments. Here, we present a novel 384-plexed easy to use lateral flow protein microarray device capable of sensitive (< 30 ng/mL determination of antigen-specific antibodies in ten minutes of total assay time. Results were developed with gold nanobeads and could be recorded by a cell-phone camera or table top scanner. Excellent accuracy with an area under curve (AUC of 98% was achieved in comparison with an established glass microarray assay for 26 antigen-specific antibodies. We propose that the presented framework could find use in convenient and cost-efficient quality control of antibody production, as well as in providing a platform for multiplexed affinity-based assays in low-resource or mobile settings.

  12. Commercial serological antibody detection tests for the diagnosis of pulmonary tuberculosis: a systematic review.

    Directory of Open Access Journals (Sweden)

    Karen R Steingart

    2007-06-01

    Full Text Available BACKGROUND: The global tuberculosis epidemic results in nearly 2 million deaths and 9 million new cases of the disease a year. The vast majority of tuberculosis patients live in developing countries, where the diagnosis of tuberculosis relies on the identification of acid-fast bacilli on unprocessed sputum smears using conventional light microscopy. Microscopy has high specificity in tuberculosis-endemic countries, but modest sensitivity which varies among laboratories (range 20% to 80%. Moreover, the sensitivity is poor for paucibacillary disease (e.g., pediatric and HIV-associated tuberculosis. Thus, the development of rapid and accurate new diagnostic tools is imperative. Immune-based tests are potentially suitable for use in low-income countries as some test formats can be performed at the point of care without laboratory equipment. Currently, dozens of distinct commercial antibody detection tests are sold in developing countries. The question is "do they work?" METHODS AND FINDINGS: We conducted a systematic review to assess the accuracy of commercial antibody detection tests for the diagnosis of pulmonary tuberculosis. Studies from all countries using culture and/or microscopy smear for confirmation of pulmonary tuberculosis were eligible. Studies with fewer than 50 participants (25 patients and 25 control participants were excluded. In a comprehensive search, we identified 68 studies. The results demonstrate that (1 overall, commercial tests vary widely in performance; (2 sensitivity is higher in smear-positive than smear-negative samples; (3 in studies of smear-positive patients, Anda-TB IgG by enzyme-linked immunosorbent assay shows limited sensitivity (range 63% to 85% and inconsistent specificity (range 73% to 100%; (4 specificity is higher in healthy volunteers than in patients in whom tuberculosis disease is initially suspected and subsequently ruled out; and (5 there are insufficient data to determine the accuracy of most

  13. Rapid Visual Tests: Fast and Reliable Detection of Ochratoxin A

    Directory of Open Access Journals (Sweden)

    Miguel Lopez-Ferber

    2010-08-01

    Full Text Available This paper reviews the early detection strategies that have been employed for the rapid monitoring of ochratoxin A (OTA contamination of food. OTA, a mycotoxin mainly produced by some Aspergillus and Penicillium species, is found in cereals, coffee, wine, pork and grapes. To minimize the entry of this mycotoxin into the food chain, rapid diagnostic tools are required. To this end, the potential use of lateral flow devices has also been developed. In this study, we analyze the robustness of test strips using published methods for colorimetric detection. Different test formats are discussed, and challenges in the development of lateral flow devices for on-site determination of OTA, with requirements such as robustness, speed, and cost-effectiveness, are discussed.

  14. A novel double antibody sandwich-lateral flow immunoassay for the rapid and simple detection of hepatitis C virus

    OpenAIRE

    XIANG, TINGXIU; JIANG, ZHENG; ZHENG, JIAN; LO, CHAOYU; TSOU, HARRY; REN, GUOSHENG; ZHANG, JUN; HUANG, AILONG; LAI, GUOQI

    2012-01-01

    The objective of this study was to screen for antigens of the hepatitis C virus (HCV) to establish a new double antibody sandwich-lateral flow immunoassay (DAS-LFIA) method for testing the presence of anti-HCV antibodies in human serum or plasma. A series of different recombinant HCV proteins in Escherichia coli cells were constructed, expressed, purified and the new DAS-LFIA strip was developed. The sensitivity and specificity of new the DAS-LFIA strip were evaluated by detecting 23 HCV-posi...

  15. Comparison of rapid diagnostic tests to detect Mycobacterium avium subsp. paratuberculosis disseminated infection in bovine liver.

    Science.gov (United States)

    Zarei, Mehdi; Ghorbanpour, Masoud; Tajbakhsh, Samaneh; Mosavari, Nader

    2017-08-01

    Mycobacterium avium subsp. paratuberculosis (MAP) causes Johne's disease, a chronic enteritis in cattle and other domestic and wild ruminants. The presence of MAP in tissues other than intestines and associated lymph nodes, such as meat and liver, is a potential public health concern. In the present study, the relationship between the results of rapid diagnostic tests of the Johne's disease, such as serum ELISA, rectal scraping PCR, and acid-fast staining, and the presence of MAP in liver was evaluated. Blood, liver, and rectal scraping samples were collected from 200 slaughtered cattle with unknown Johne's disease status. ELISA was performed to determine the MAP antibody activity in the serum. Acid-fast staining was performed on rectal scraping samples, and PCR was performed on rectal scraping and liver samples. PCR-positive liver samples were used for mycobacterial culture. Overall, the results of this study demonstrated that MAP can be detected and cultured from liver of slaughtered cattle and rapid diagnostic tests of Johne's disease have limited value in detecting cattle with MAP infection in liver. These findings show that the presence of MAP in liver tissue may occur in cows with negative results for rapid diagnostic tests and vice versa. Hence, liver might represent another possible risk of human exposure to MAP. Given concerns about a potential zoonotic role for MAP, these results show the necessity to find new methods for detecting cattle with MAP disseminated infection.

  16. Development of a Rapid Qualitative Assay for Determining Elevated Antibody Levels to Periodontopathic Organisms

    Science.gov (United States)

    1990-01-01

    antibody to several species of Nocardia in an attempt to ease diagnosis of the disease. They found that 100% of sera from patients with confirmed...Identification of a common immunodominant protein in culture filtrates of.hree Nocardia species and use in etiologic diagnosis of mycetoma. J. Clin

  17. Pentamerization of single-domain antibodies from phage libraries: a novel strategy for the rapid generation of high-avidity antibody reagents.

    Science.gov (United States)

    Zhang, Jianbing; Tanha, Jamshid; Hirama, Tomoko; Khieu, Nam Huan; To, Rebecca; Tong-Sevinc, Hong; Stone, Emily; Brisson, Jean Robert; MacKenzie, C Roger

    2004-01-02

    We describe a novel type of molecule in which single-domain antibodies (sdAbs) isolated from a nai;ve llama single domain antibody library are linked to an oligomerization domain to generate high-avidity, antigen-binding reagents. An sdAb is fused to the B-subunit of Escherichia coli verotoxin, or shiga-like toxin, which self-assembles to form a homopentamer and results in simultaneous sdAb pentamerization and introduction of avidity. Molecular modeling indicated that this fusion protein (PDB: 1OJF), termed pentabody, has structural flexibility for binding to surface-presented antigen. In the instance of an sdAb specific for a peptide antigen, pentamerization resulted in a dramatic increase in functional affinity for immobilized antigen. The pentabody was expressed in high yield in E.coli in a non-aggregated state, and exhibited excellent thermostability and protease resistance. This technology provides a relatively rapid means of generating novel antigen-binding molecules that bind strongly to immobilized antigen. It is expected that pentavalent sdAbs will have general applicability in proteomics, immunochemical staining, cancer diagnosis and other applications in which antigens are presented multivalently.

  18. Comparison between the Counter Immunoelectrophoresis Test and Mouse Neutralization Test for the Detection of Antibodies against Rabies Virus in Dog Sera

    Directory of Open Access Journals (Sweden)

    Luzia Helena Queiroz da Silva

    2002-03-01

    Full Text Available The detection of rabies antibodies is extremely valuable for epidemiological studies, determination of immune status in man, animals, and for the diagnosis of the disease. Several serological procedures have been described for this purpose. The present study reports a comparison between counterimmunoelectrophoresis test (CIET and mouse neutralization test (MNT in the detection of antibodies against rabies virus from 212 serum samples of vaccinated dogs. The agreement between both techniques was 79.7% and a significative association was demonstrated. The correlation coefficients between MNT and the CIET titers was determined considering 88 samples showing positive results in both techniques [CIET = 2 and MNT = 5 (0.13 IU/ml] and resulted r² = 0.7926 (p < 0.001. The performance of CIET system was technically simple, cheap and rapid, and thereby it could be useful for serological monitoring of dog vaccination campaigns as well as for individual analysis.

  19. [Rapid test for detection of susceptibility to cefotaxime in Enterobacteriaceae].

    Science.gov (United States)

    Jiménez-Guerra, Gemma; Hoyos-Mallecot, Yannik; Rodríguez-Granger, Javier; Navarro-Marí, José María; Gutiérrez-Fernández, José

    In this work an "in house" rapid test based on the change in pH that is due to hydrolysis for detecting Enterobacteriaceae susceptible to cefotaxime is evaluated. The strains of Enterobacteriaceae from 1947 urine cultures were assessed using MicroScan panels and the "in house" test. This rapid test includes red phenol solution and cefotaxime. Using MicroScan panels, 499 Enterobacteriaceae isolates were evaluated, which included 27 isolates of Escherichia coli producing extended-spectrum beta-lactamases (ESBL), 16 isolates of Klebsiella pneumoniae ESBL and 1 isolate of Klebsiella oxytoca ESBL. The "in house" test offers the following values: sensitivity 98% and specificity 97%, with negative predictive value 100% and positive predictive value 78%. The "in house" test based on the change of pH is useful in our area for detecting presumptively cefotaxime-resistant Enterobacteriaceae strains. Copyright © 2016 Asociación Argentina de Microbiología. Publicado por Elsevier España, S.L.U. All rights reserved.

  20. Triple positive antiphospholipid antibody profile in outpatients with tests for lupus anticoagulants.

    Science.gov (United States)

    Froom, Paul; Saffuri-Elias, Enas; Rozenberg, Orit; Barak, Mira

    2015-01-01

    A triple positive antiphospholipid (aPL) antibody profile [two positive serum IgG aPL antibodies along with one positive functional plasma lupus anticoagulant (LAC) test result] is associated with an increased risk for thrombosis, whereas patients with single positive test results may have little to no increased risk. The frequency of triple positivity in outpatients with various combinations of LAC test results is unclear. We extracted from our database all LAC test results [dilute Russell viper venom times (dRVVT) and silica clotting times (SCT)] that had concomitant serum IgG aPL testing [both serum anti β2-glycoprotein I (anti-β2GPI) and anti-cardiolipin (aCL) antibodies]. There were 3195 patients without a prolonged prothrombin time. Double antibody positivity was found in 1% (31/2955) of those with normal functional LAC test results, in 16.0% (31/81) of those with a positive dRVVT, in 12.7% (10/79) of those with a positive SCT, and in 56.3% (45/80) of those with both tests positive (pLAC test result. We conclude that 28% of patients with elevated LAC tests have a triple positive aPL antibody profile and patients with two positive LAC tests have a higher prevalence of a triple positive profile than do those with one positive LAC test result.

  1. Fingertip rapid point-of-care test in adult case-finding in coeliac disease.

    Science.gov (United States)

    Popp, Alina; Jinga, Mariana; Jurcut, Ciprian; Balaban, Vasile; Bardas, Catalina; Laurila, Kaija; Vasilescu, Florina; Ene, Adina; Anca, Ioana; Mäki, Markku

    2013-07-12

    Coeliac disease (CD), due to its protean clinical manifestation, is still very under diagnosed in adults and delays in diagnosis may take years and even decades. Simple tools to find cases in primary care may help to identify patients for further diagnostic tests. We have evaluated the usefulness of an on site rapid fingertip whole blood point-of-care test (POCT) for such a purpose. As CD is known to run within families, we tested 148 healthy relatives of 70 Romanian index cases with biopsy-proven CD (87% of all first-degree family members, median age 36 years) for the presence of circulating autoantibodies. In addition to performing the POCT (which measures blood erythrocyte self-TG2-autoantibody complexes) on site, blood was drawn for later evaluations of serum IgA-class endomysial antibodies (EMA). EMA-positive sera were further tested for transglutaminase 2 antibodies (TG2-IgA). All serological parameters were analyzed blindly in a centralized laboratory that had no knowledge of the on site POCT result. Endoscopic small intestinal biopsies was recommended for all POCT- or EMA-test positive subjects. In on site testing the POCT was positive in 12/148 first-degree relatives (8%) and all these subjects were also serum EMA-positive. A positive EMA test was found only in one other subject. All remaining 135 healthy first-degree relatives were negative for both POCT and EMA. Four subjects positive for both POCT and EMA were negative for TG2-IgA. Ten out of thirteen of the antibody-positive subjects agreed to undergo endoscopy. The POCT was found to be positive in 8/9 first-degree relatives having coeliac-type mucosal lesions of grade Marsh 2 (n = 3) or Marsh 3 (n = 6). The three POCT-positive subjects not agreeing to undergo endoscopy were also both EMA- and TG2-IgA-positive. The fingertip whole blood rapid POCT might fulfill the unmet need for a simple and cheap case-finding biomarker for early detection and presumptive diagnosis of CD. Confirmatory studies

  2. Rapid diagnostic tests for diagnosing uncomplicated non-falciparum or Plasmodium vivax malaria in endemic countries

    Science.gov (United States)

    Abba, Katharine; Kirkham, Amanda J; Olliaro, Piero L; Deeks, Jonathan J; Donegan, Sarah; Garner, Paul; Takwoingi, Yemisi

    2014-01-01

    Background In settings where both Plasmodium vivax and Plasmodium falciparum infection cause malaria, rapid diagnostic tests (RDTs) need to distinguish which species is causing the patients' symptoms, as different treatments are required. Older RDTs incorporated two test lines to distinguish malaria due to P. falciparum, from malaria due to any other Plasmodium species (non-falciparum). These RDTs can be classified according to which antibodies they use: Type 2 RDTs use HRP-2 (for P. falciparum) and aldolase (all species); Type 3 RDTs use HRP-2 (for P. falciparum) and pLDH (all species); Type 4 use pLDH (fromP. falciparum) and pLDH (all species). More recently, RDTs have been developed to distinguish P. vivax parasitaemia by utilizing a pLDH antibody specific to P. vivax. Objectives To assess the diagnostic accuracy of RDTs for detecting non-falciparum or P. vivax parasitaemia in people living in malaria-endemic areas who present to ambulatory healthcare facilities with symptoms suggestive of malaria, and to identify which types and brands of commercial test best detect non-falciparum and P. vivax malaria. Search methods We undertook a comprehensive search of the following databases up to 31 December 2013: Cochrane Infectious Diseases Group Specialized Register; MEDLINE; EMBASE; MEDION; Science Citation Index; Web of Knowledge; African Index Medicus; LILACS; and IndMED. Selection criteria Studies comparing RDTs with a reference standard (microscopy or polymerase chain reaction) in blood samples from a random or consecutive series of patients attending ambulatory health facilities with symptoms suggestive of malaria in non-falciparum endemic areas. Data collection and analysis For each study, two review authors independently extracted a standard set of data using a tailored data extraction form. We grouped comparisons by type of RDT (defined by the combinations of antibodies used), and combined in meta-analysis where appropriate. Average sensitivities and

  3. Rapid screening test for porphyria diagnosis using fluorescence spectroscopy

    Science.gov (United States)

    Lang, A.; Stepp, H.; Homann, C.; Hennig, G.; Brittenham, G. M.; Vogeser, M.

    2015-07-01

    Porphyrias are rare genetic metabolic disorders, which result from deficiencies of enzymes in the heme biosynthesis pathway. Depending on the enzyme defect, different types of porphyrins and heme precursors accumulate for the different porphyria diseases in erythrocytes, liver, blood plasma, urine and stool. Patients with acute hepatic porphyrias can suffer from acute neuropathic attacks, which can lead to death when undiagnosed, but show only unspecific clinical symptoms such as abdominal pain. Therefore, in addition to chromatographic methods, a rapid screening test is required to allow for immediate identification and treatment of these patients. In this study, fluorescence spectroscopic measurements were conducted on blood plasma and phantom material, mimicking the composition of blood plasma of porphyria patients. Hydrochloric acid was used to differentiate the occurring porphyrins (uroporphyrin-III and coproporphyrin-III) spectroscopically despite their initially overlapping excitation spectra. Plasma phantom mixtures were measured using dual wavelength excitation and the corresponding concentrations of uroporphyrin-III and coproporphyrin-III were determined. Additionally, three plasma samples of porphyria patients were examined and traces of coproporphyrin-III and uroporphyrin-III were identified. This study may therefore help to establish a rapid screening test method with spectroscopic differentiation of the occurring porphyrins, which consequently allows for the distinction of different porphyrias. This may be a valuable tool for clinical porphyria diagnosis and rapid or immediate treatment.

  4. A comparison of standard acute toxicity tests with rapid-screening toxicity tests

    Energy Technology Data Exchange (ETDEWEB)

    Toussaint, M.W. [Geo-Centers, Inc., Fort Washington, MD (United States); Shedd, T.R. [Army Biomedical Research and Development Lab., Frederick, MD (United States); Schalie, W.H. van der [Environmental Protection Agency, Washington, DC (United States); Leather, G.R. [Hood Coll., Frederick, MD (United States). Dept. of Biology

    1995-05-01

    This study compared the relative sensitivity of five inexpensive, rapid toxicity tests to the sensitivity of five standard aquatic acute toxicity tests through literature review and testing. The rapid toxicity tests utilized organisms that require little culturing or handling prior to testing: a freshwater rotifer (Branchionus calyciflorus); brine shrimp (Artemia salina); lettuce (Lactuca sativa); and two microbial tests (Photobacterium phosphoreum--Microtox{reg_sign} test, and a mixture of bacterial species--the Polytox{reg_sign} test). Standard acute toxicity test species included water fleas (Daphnia magna and Ceriodaphnia dubia), green algae (Selenastrum capricornutum), fathead minnows (Pimephales promelas), and mysid shrimp (Mysidopsis bahia). Sensitivity comparisons between rapid and standard acute toxicity tests were based on LC50/EC50 data from 11 test chemicals. Individually, the lettuce and rotifer tests ranked most similar in sensitivity to the standard tests, while Microtox fell just outside the range of sensitivities represented by the group of standard acute toxicity tests. The brine shrimp and Polytox tests were one or more orders of magnitude different from the standard acute toxicity tests for most compounds. The lettuce, rotifer, and Microtox tests could be used as a battery for preliminary toxicity screening of chemicals. Further evaluation of complex real-world environmental samples is recommended.

  5. Mono Test

    Science.gov (United States)

    ... Heterophile Test Heterophile Antibody Test Monospot Formal Name Infectious Mononucleosis Rapid Test This article was last reviewed on ... Why Get Tested? To detect and help diagnose infectious mononucleosis (mono) When To Get Tested? When a person, ...

  6. A Lateral Flow Protein Microarray for Rapid and Sensitive Antibody Assays

    Science.gov (United States)

    Gantelius, Jesper; Bass, Tarek; Sjöberg, Ronald; Nilsson, Peter; Andersson-Svahn, Helene

    2011-01-01

    Protein microarrays are useful tools for highly multiplexed determination of presence or levels of clinically relevant biomarkers in human tissues and biofluids. However, such tools have thus far been restricted to laboratory environments. Here, we present a novel 384-plexed easy to use lateral flow protein microarray device capable of sensitive (gold nanobeads and could be recorded by a cell-phone camera or table top scanner. Excellent accuracy with an area under curve (AUC of 98% was achieved in comparison with an established glass microarray assay for 26 antigen-specific antibodies. We propose that the presented framework could find use in convenient and cost-efficient quality control of antibody production, as well as in providing a platform for multiplexed affinity-based assays in low-resource or mobile settings. PMID:22174629

  7. A comparison of test statistics for the recovery of rapid growth-based enumeration tests

    NARCIS (Netherlands)

    van den Heuvel, Edwin R.; IJzerman-Boon, Pieta C.

    This paper considers five test statistics for comparing the recovery of a rapid growth-based enumeration test with respect to the compendial microbiological method using a specific nonserial dilution experiment. The finite sample distributions of these test statistics are unknown, because they are

  8. A sensitive and specific lateral flow assay for rapid detection of antibodies against glycoprotein B of Aujeszky's disease virus.

    Science.gov (United States)

    Vrublevskaya, Veronika V; Afanasyev, Vladimir N; Grinevich, Andrey A; Skarga, Yuri Y; Gladyshev, Pavel P; Ibragimova, Sagila A; Krylsky, Dmitry V; Dezhurov, Sergey V; Morenkov, Oleg S

    2017-11-01

    A direct double antibody lateral flow assay (DDA-gB-LFA) for the detection of antibodies against the glycoprotein B (gB) of Aujeszky's disease virus (ADV) in swine sera was developed. A native ADV gB was used for the preparation of a conjugate with colloidal gold particles and the immobilization on the strip membrane. The gB purified from ADV virions by immunoaffinity chromatography retained its native epitope structure after adsorption on the nitrocellulose membrane and the surface of colloidal gold particles. The diagnostic specificity and sensitivity of the DDA-gB-LFA were evaluated using 236 field swine sera. The diagnostic specificity and sensitivity of the DDA-gB-LFA compared to a commercially available gB-based ELISA were 98.0% and 98.6%, respectively, when determined with the use of the reader-detection mode, and 98.0% and 93.5%, respectively, when determined using visual detection. The DDA-gB-LFA provides a rapid, sensitive, and specific determination of ADV gB-directed antibodies in sera and can be used for the detection of ADV-exposed swine. Copyright © 2017. Published by Elsevier B.V.

  9. Rapid characterization of hybridomas producing monoclonal antibodies against platelet β3 integrin using ELIspot.

    Science.gov (United States)

    Maenner, Denis; Werth, Silke; Bein, Gregor; Santoso, Sentot

    2016-12-01

    Generally, B-cell responses against human platelet antigens are assessed by the serological detection of specific platelet antibodies, mostly against β3 integrin. However, this approach seems to be of low sensitivity, since platelet autoantibodies against αIIbβ3 are detected in only 50% of all patients with immune thrombocytopenia (ITP). In this study, a novel B-cell ELIspot method was established to characterize the specificity of mouse monoclonal antibodies (moabs) against human β3 integrin. Moabs produced by hybridomas were immobilized on membrane and bound antibodies were visualized as spots using biotinylated recombinant proteins αIIbβ3 or αvβ3 and the enzyme labeled streptavidin-substrate system. Three hybridomas, Gi5, Gi16 and AP3, designated previously as anti-αIIbβ3, anti-αIIb and anti-β3, respectively, were investigated. Hybridoma producing moab against CD177 was used as the negative control. Whereas AP3 reacted with αIIbβ3 and αvβ3, Gi5 only formed spots with αIIbβ3. Titration analysis showed that the number of spots correlated significantly with the number of seeded cells. Approximately 15 antibody producing hybridoma cells could be identified among 103 nonproducing B-cells. Furthermore, superior correlation with the total number of IgG producing cells was obtained. Analysis of the third hybridoma, Gi16 (anti-αIIb), showed only few spots with αIIbβ3, indicating that this hybridoma contained different clones (producer and non-producer). Significant increased number of spots could be identified after re-cloning of these clones by limiting dilution method. Our results demonstrate that this B-cell ELIspot assay can be used for the identification of a small number of hybridoma cells producing moabs against β3 integrin, verification of their monoclonality, productivity and for determining their specificity in the early state of workup steps. In the future, this approach may be useful to define B-cell clones in patients who developed

  10. Rapid diagnostic tests for typhoid and paratyphoid (enteric) fever

    Science.gov (United States)

    Wijedoru, Lalith; Mallett, Sue; Parry, Christopher M

    2017-01-01

    Background Differentiating both typhoid (Salmonella Typhi) and paratyphoid (Salmonella Paratyphi A) infection from other causes of fever in endemic areas is a diagnostic challenge. Although commercial point-of-care rapid diagnostic tests (RDTs) for enteric fever are available as alternatives to the current reference standard test of blood or bone marrow culture, or to the widely used Widal Test, their diagnostic accuracy is unclear. If accurate, they could potentially replace blood culture as the World Health Organization (WHO)-recommended main diagnostic test for enteric fever. Objectives To assess the diagnostic accuracy of commercially available rapid diagnostic tests (RDTs) and prototypes for detecting Salmonella Typhi or Paratyphi A infection in symptomatic persons living in endemic areas. Search methods We searched the Cochrane Infectious Diseases Group Specialized Register, MEDLINE, Embase, Science Citation Index, IndMED, African Index Medicus, LILACS, ClinicalTrials.gov, and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) up to 4 March 2016. We manually searched WHO reports, and papers from international conferences on Salmonella infections. We also contacted test manufacturers to identify studies. Selection criteria We included diagnostic accuracy studies of enteric fever RDTs in patients with fever or with symptoms suggestive of enteric fever living in endemic areas. We classified the reference standard used as either Grade 1 (result from a blood culture and a bone marrow culture) or Grade 2 (result from blood culture and blood polymerase chain reaction, or from blood culture alone). Data collection and analysis Two review authors independently extracted the test result data. We used a modified QUADAS-2 extraction form to assess methodological quality. We performed a meta-analysis when there were sufficient studies for the test and heterogeneity was reasonable. Main results Thirty-seven studies met the inclusion

  11. The effects of surface treatments on rapid chloride permeability tests

    KAUST Repository

    Yoon, Seyoon

    2012-08-01

    Surface treatments are commonly applied to improve the chloride resistance of concrete structures exposed to saline environments. Information on chloride ingress to surface-treated concrete is mostly provided by application of the rapid chloride permeability test (RCPT); this test is short in duration and provides rapid results. This study presents a numerical formulation, based on the extended Nernst-Plank/Poisson (NPP) equation, to model the effect of the surface treatment on a sample tested by RCPT. Predictions of the model are compared to experimental measurements. The simulations show that the results from RCPT, in terms of ionic profiles and measurement of the electric field, are dependent on the effectiveness of surface treatments. During RCPT, highly effective surface treatments cause both cations and anions to flocculate at the interface between the surface treatment and the concrete, creating a local electric field. Our numerical model includes these phenomena and presents a methodology to obtain more accurate diffusivities of the surface-treated- concrete from RCPT. © 2012 Elsevier B.V. All rights reserved.

  12. Measurement of antibodies to varicella-zoster virus using a virus-free fluorescent-antibody-to-membrane-antigen (FAMA) test.

    Science.gov (United States)

    Park, Rackhyun; Hwang, Ji Young; Lee, Kang Il; Namkoong, Sim; Choi, Seuk-Keun; Park, Songyong; Park, Hosun; Park, Junsoo

    2015-02-01

    The fluorescent-antibody-to-membrane-antigen (FAMA) test is regarded as the "gold standard" to detect protective antibodies to varicella-zoster virus (VZV) because of its high sensitivity and specificity. Because the classic FAMA test uses an infectious virus for detection of antibodies to VZV, it is labor-intensive, and also requires special equipment for handling the virus. For this reason, we attempted to develop a simple and safe FAMA assay. Because VZV glycoprotein E (gE) is one of the major VZV glycoproteins, we used the gE protein for the FAMA test (gE FAMA). Here, we demonstrate that overexpression of gE in HEK293T cells can be used to measure antibodies in human serum, and that gE FAMA titers are closely correlated with gpEIA ELISA data. These results indicate that our gE FAMA test has the potential to measure antibodies to VZV.

  13. Potential for false positive HIV test results with the serial rapid HIV testing algorithm

    Directory of Open Access Journals (Sweden)

    Baveewo Steven

    2012-03-01

    Full Text Available Abstract Background Rapid HIV tests provide same-day results and are widely used in HIV testing programs in areas with limited personnel and laboratory infrastructure. The Uganda Ministry of Health currently recommends the serial rapid testing algorithm with Determine, STAT-PAK, and Uni-Gold for diagnosis of HIV infection. Using this algorithm, individuals who test positive on Determine, negative to STAT-PAK and positive to Uni-Gold are reported as HIV positive. We conducted further testing on this subgroup of samples using qualitative DNA PCR to assess the potential for false positive tests in this situation. Results Of the 3388 individuals who were tested, 984 were HIV positive on two consecutive tests, and 29 were considered positive by a tiebreaker (positive on Determine, negative on STAT-PAK, and positive on Uni-Gold. However, when the 29 samples were further tested using qualitative DNA PCR, 14 (48.2% were HIV negative. Conclusion Although this study was not primarily designed to assess the validity of rapid HIV tests and thus only a subset of the samples were retested, the findings show a potential for false positive HIV results in the subset of individuals who test positive when a tiebreaker test is used in serial testing. These findings highlight a need for confirmatory testing for this category of individuals.

  14. Potential for false positive HIV test results with the serial rapid HIV testing algorithm.

    Science.gov (United States)

    Baveewo, Steven; Kamya, Moses R; Mayanja-Kizza, Harriet; Fatch, Robin; Bangsberg, David R; Coates, Thomas; Hahn, Judith A; Wanyenze, Rhoda K

    2012-03-19

    Rapid HIV tests provide same-day results and are widely used in HIV testing programs in areas with limited personnel and laboratory infrastructure. The Uganda Ministry of Health currently recommends the serial rapid testing algorithm with Determine, STAT-PAK, and Uni-Gold for diagnosis of HIV infection. Using this algorithm, individuals who test positive on Determine, negative to STAT-PAK and positive to Uni-Gold are reported as HIV positive. We conducted further testing on this subgroup of samples using qualitative DNA PCR to assess the potential for false positive tests in this situation. Of the 3388 individuals who were tested, 984 were HIV positive on two consecutive tests, and 29 were considered positive by a tiebreaker (positive on Determine, negative on STAT-PAK, and positive on Uni-Gold). However, when the 29 samples were further tested using qualitative DNA PCR, 14 (48.2%) were HIV negative. Although this study was not primarily designed to assess the validity of rapid HIV tests and thus only a subset of the samples were retested, the findings show a potential for false positive HIV results in the subset of individuals who test positive when a tiebreaker test is used in serial testing. These findings highlight a need for confirmatory testing for this category of individuals.

  15. Incorporating Direct Rapid Immunohistochemical Testing into Large-Scale Wildlife Rabies Surveillance

    Directory of Open Access Journals (Sweden)

    Kevin Middel

    2017-06-01

    Full Text Available Following an incursion of the mid-Atlantic raccoon variant of the rabies virus into southern Ontario, Canada, in late 2015, the direct rapid immunohistochemical test for rabies (dRIT was employed on a large scale to establish the outbreak perimeter and to diagnose specific cases to inform rabies control management actions. In a 17-month period, 5800 wildlife carcasses were tested using the dRIT, of which 307 were identified as rabid. When compared with the gold standard fluorescent antibody test (FAT, the dRIT was found to have a sensitivity of 100% and a specificity of 98.2%. Positive and negative test agreement was shown to be 98.3% and 99.1%, respectively, with an overall test agreement of 98.8%. The average cost to test a sample was $3.13 CAD for materials, and hands-on technical time to complete the test is estimated at 0.55 h. The dRIT procedure was found to be accurate, fast, inexpensive, easy to learn and perform, and an excellent tool for monitoring the progression of a wildlife rabies incursion.

  16. [Field assessment of the new rapid diagnostic test Ebola eZYSCREEN®].

    Science.gov (United States)

    Gallais, F; Gay-Andrieu, F; Picot, V; Magassouba, N; Mély, S; Peyrefitte, C N; Bellanger, L

    2017-02-01

    During the Ebola virus disease outbreak in West Africa in 2014, the World Health Organization has pointed out the need for rapid diagnostic tests (RDT) affordable, sensitive, specific, user-friendly, rapid, equipment-free, and deliverable. The rapid diagnostic test (Lateral Flow Assay) Ebola eZYSCREEN® was developed in this emergency frame using monoclonal antibodies against the envelope glycoprotein of the virus. Two distinct versions have been industrialized, one for whole-blood samples and the other for serum/plasma samples. Both versions have an analytical detection limit of 10 5 pfu/ml, the stability is at least 393 days at 30°C and 120 days at 45°C. The nonretrospective and independent validation study was carried out in the course of the outbreak in Conakry and at the Ebola Treatment Center of Coyah (Guinea) on 144 patients. In this study, the RDT showed a sensitivity of 65.3% and a specificity of 98.9% on whole blood, a sensitivity of 74.5% and a specificity of 100% on serum. Results from the whole-blood version must be analyzed with caution because of the delay between the blood collection and the completion of the tests, which was out of specification (3 days on average instead of 2 h). In contrast to laboratory tests, this easy to use field test does not require sophisticated instrumentation or even electricity and can contribute to the diagnostic chain of Ebola virus disease taking into account its benefits, high stability, and specificity but also its limit of sensitivity compared to laboratory techniques RT-qPCR (Real-Time reverse transcription Polymerase Chain Reaction), which remain the reference for the diagnosis of Ebola. The RDT Ebola eZYSCREEN® was granted EC IVD (IVD = In Vitro Diagnostic) marking.

  17. Introducing rapid tests for malaria into the retail sector

    DEFF Research Database (Denmark)

    Hutchinson, Eleanor; Hutchison, Coll; Lal, Sham

    2017-01-01

    The observation that many people in Africa seek care for febrile illness in the retail sector has led to a number of public health initiatives to try to improve the quality of care provided in these settings. The potential to support the introduction of rapid diagnostic tests for malaria (m......RDTs) into drug shops is coming under increased scrutiny. Those in favour argue that it enables the harmonisation of policy around testing and treatment for malaria and maintains a focus on market-based solutions to healthcare. Despite the enthusiasm among many global health actors for this policy option......, there is a limited understanding of the consequences of the introduction of mRDTs in the retail sector. We undertook an interpretive, mixed methods study with drug shop vendors (DSVs), their clients and local health workers to explore the uses and interpretations of mRDTs as they became part of daily practice...

  18. Laboratory and On-Site Tests for Rapid Runway Repair

    Directory of Open Access Journals (Sweden)

    Federico Leonelli

    2017-11-01

    Full Text Available The attention to rapid pavement repair has grown fast in recent decades: this topic is strategic for the airport management process for civil purposes and peacekeeping missions. This work presents the results of laboratory and on-site tests for rapid runway repair, in order to analyse and compare technical and mechanical performances of 12 different materials currently used in airport. The study focuses on site repairs, a technique adopted most frequently than repairs with modular elements. After describing mechanical and physical properties of the examined materials (2 bituminous emulsions, 5 cement mortars, 4 cold bituminous mixtures and 1 expanding resin, the study presents the results of carried out mechanical tests. The results demonstrate that the best performing material is a one-component fast setting and hardening cement mortar with graded aggregates. This material allows the runway reopening 6 h after the work. A cold bituminous mixture (bicomponent premixed cold asphalt with water as catalyst and the ordinary cement concrete allow the reopening to traffic after 18 h, but both ensure a lower service life (1000 coverages than the cement mortar (10,000 coverages. The obtained results include important information both laboratory level and field, and they could be used by airport management bodies and road agencies when scheduling and evaluating pavement repairs.

  19. Accuracy and user-acceptability of HIV self-testing using an oral fluid-based HIV rapid test.

    Directory of Open Access Journals (Sweden)

    Oon Tek Ng

    Full Text Available BACKGROUND: The United States FDA approved an over-the-counter HIV self-test, to facilitate increased HIV testing and earlier linkage to care. We assessed the accuracy of self-testing by untrained participants compared to healthcare worker (HCW testing, participants' ability to interpret sample results and user-acceptability of self-tests in Singapore. METHODOLOGY/PRINCIPAL FINDINGS: A cross-sectional study, involving 200 known HIV-positive patients and 794 unknown HIV status at-risk participants was conducted. Participants (all without prior self-test experience performed self-testing guided solely by visual instructions, followed by HCW testing, both using the OraQuick ADVANCE Rapid HIV 1/2 Antibody Test, with both results interpreted by the HCW. To assess ability to interpret results, participants were provided 3 sample results (positive, negative, and invalid to interpret. Of 192 participants who tested positive on HCW testing, self-testing was positive in 186 (96.9%, negative in 5 (2.6%, and invalid in 1 (0.5%. Of 794 participants who tested negative on HCW testing, self-testing was negative in 791 (99.6%, positive in 1 (0.1%, and invalid in 2 (0.3%. Excluding invalid tests, self-testing had sensitivity of 97.4% (95% CI 95.1% to 99.7% and specificity of 99.9% (95% CI: 99.6% to 100%. When interpreting results, 96%, 93.1% and 95.2% correctly read the positive, negative and invalid respectively. There were no significant demographic predictors for false negative self-testing or wrongly interpreting positive or invalid sample results as negative. Eighty-seven percent would purchase the kit over-the-counter; 89% preferred to take HIV tests in private. 72.5% and 74.9% felt the need for pre- and post-test counseling respectively. Only 28% would pay at least USD15 for the test. CONCLUSIONS/SIGNIFICANCE: Self-testing was associated with high specificity, and a small but significant number of false negatives. Incorrectly identifying model results as

  20. Accuracy and user-acceptability of HIV self-testing using an oral fluid-based HIV rapid test.

    Science.gov (United States)

    Ng, Oon Tek; Chow, Angela L; Lee, Vernon J; Chen, Mark I C; Win, Mar Kyaw; Tan, Hiok Hee; Chua, Arlene; Leo, Yee Sin

    2012-01-01

    The United States FDA approved an over-the-counter HIV self-test, to facilitate increased HIV testing and earlier linkage to care. We assessed the accuracy of self-testing by untrained participants compared to healthcare worker (HCW) testing, participants' ability to interpret sample results and user-acceptability of self-tests in Singapore. A cross-sectional study, involving 200 known HIV-positive patients and 794 unknown HIV status at-risk participants was conducted. Participants (all without prior self-test experience) performed self-testing guided solely by visual instructions, followed by HCW testing, both using the OraQuick ADVANCE Rapid HIV 1/2 Antibody Test, with both results interpreted by the HCW. To assess ability to interpret results, participants were provided 3 sample results (positive, negative, and invalid) to interpret. Of 192 participants who tested positive on HCW testing, self-testing was positive in 186 (96.9%), negative in 5 (2.6%), and invalid in 1 (0.5%). Of 794 participants who tested negative on HCW testing, self-testing was negative in 791 (99.6%), positive in 1 (0.1%), and invalid in 2 (0.3%). Excluding invalid tests, self-testing had sensitivity of 97.4% (95% CI 95.1% to 99.7%) and specificity of 99.9% (95% CI: 99.6% to 100%). When interpreting results, 96%, 93.1% and 95.2% correctly read the positive, negative and invalid respectively. There were no significant demographic predictors for false negative self-testing or wrongly interpreting positive or invalid sample results as negative. Eighty-seven percent would purchase the kit over-the-counter; 89% preferred to take HIV tests in private. 72.5% and 74.9% felt the need for pre- and post-test counseling respectively. Only 28% would pay at least USD15 for the test. Self-testing was associated with high specificity, and a small but significant number of false negatives. Incorrectly identifying model results as invalid was a major reason for incorrect result interpretation. Survey

  1. Mortality among British Columbians testing for hepatitis C antibody

    National Research Council Canada - National Science Library

    Yu, Amanda; Spinelli, John J; Cook, Darrel A; Buxton, Jane A; Krajden, Mel

    2013-01-01

    .... The ability to link population based centralized laboratory HCV testing data with administrative databases provided a unique opportunity to compare mortality between HCV seronegative and seropositive individuals...

  2. Accuracy of individual rapid tests for serodiagnosis of gambiense sleeping sickness in West Africa.

    Directory of Open Access Journals (Sweden)

    Vincent Jamonneau

    2015-02-01

    Full Text Available Individual rapid tests for serodiagnosis (RDT of human African trypanosomiasis (HAT are particularly suited for passive screening and surveillance. However, so far, no large scale evaluation of RDTs has been performed for diagnosis of Trypanosoma brucei gambiense HAT in West Africa. The objective of this study was to assess the diagnostic accuracy of 2 commercial HAT-RDTs on stored plasma samples from West Africa.SD Bioline HAT and HAT Sero-K-Set were performed on 722 plasma samples originating from Guinea and Côte d'Ivoire, including 231 parasitologically confirmed HAT patients, 257 healthy controls, and 234 unconfirmed individuals whose blood tested antibody positive in the card agglutination test but negative by parasitological tests. Immune trypanolysis was performed as a reference test for trypanosome specific antibody presence. Sensitivities in HAT patients were respectively 99.6% for SD Bioline HAT, and 99.1% for HAT Sero-K-Set, specificities in healthy controls were respectively 87.9% and 88.3%. Considering combined positivity in both RDTs, increased the specificity significantly (p ≤ 0.0003 to 93.4%, while 98.7% sensitivity was maintained. Specificities in controls were 98.7-99.6% for the combination of one or two RDTs with trypanolysis, maintaining a sensitivity of at least 98.1%.The observed specificity of the single RDTs was relatively low. Serial application of SD Bioline HAT and HAT Sero-K-Set might offer superior specificity compared to a single RDT, maintaining high sensitivity. The combination of one or two RDTs with trypanolysis seems promising for HAT surveillance.

  3. [False positives and false negatives seen in anti-HIV-1 antibody tests].

    Science.gov (United States)

    Osato, K; Matsubayashi, T; Nagao, T; Inuzumi, K; Araki, H; Kawai, K

    1994-08-01

    From September 1986 to December 1993 31059 anti-HIV antibody tests were performed on the samples from our clinic, from 29 health centers and their branches of Osaka Prefecture, from a hospital and from high risk groups. Enzyme immune assay (EIA) was used up to 1988 and from 1989 particle agglutination (PA) has been employed. The indeterminates of Western blot (WB) were seen in 5 EIA positives and in 2 PA positives. False positive rate of EIA was 0.235% (11/467) and that of PA was 0.011% (2/17922). Two false negative cases of anti-HIV-1 antibody test due to window period were documented and the importance of co-use of antigen test at the time of confirmative antibody tests was discussed.

  4. False positive rate of rapid oral fluid HIV tests increases as kits near expiration date.

    Science.gov (United States)

    Facente, Shelley N; Dowling, Teri; Vittinghoff, Eric; Sykes, Deanna L; Colfax, Grant N

    2009-12-14

    Because a recent cluster of false positive results on the OraQuick ADVANCE Rapid HIV-1/2 Antibody Test occurred in San Francisco on test kits close to their expiration date, we decided to assess the relationship between time to expiration and rate of false positive results from tests used with oral fluid. We analyzed results of 20,904 tests with either an initial HIV-negative result (n = 20,828) or a preliminary positive result that was then negative on confirmatory tests (n = 76). We computed specificity for kits with time to expiration from or = 6 months, with exact binomial confidence intervals, then used logistic regression to estimate the independent association of time to expiration with false positive results, adjusting for site and technician effects. For 1,108 kits used in the last month before expiration, specificity was 98.83% (95% exact binomial confidence interval (CI) 98.00%-99.37%); the upper bound is below the claimed specificity of 99.60%. After adjustment using regression standardization for the effects of site, test lot, and technician factors, adjusted specificity in the last month before expiration was 99.18% (95% bootstrap confidence interval 98.60-99.57%). We found that specificity of the OraQuick ADVANCE with oral fluid declined significantly with < or = 1 month remaining to expiration, leaving little margin for error from other sources.

  5. Is there a role for antibody testing in the diagnosis of invasive candidiasis?

    Science.gov (United States)

    Quindós, Guillermo; Moragues, María Dolores; Pontón, José

    2004-03-01

    During the last decades, the use of antibody tests for the diagnosis of invasive mycoses has declined as a consequence of the general belief that they are insensitive and non-specific. However, there is a clear evidence that antibodies can be detected in highly immunodeficient patients (such as bone marrow transplant recipients), and that those antibodies are useful for the diagnosis. Antibody tests are currently in use as diagnostic tools for some primary mycoses, such as the endemic mycoses, aspergilloma, allergic bronchopulmonary aspergilosis and sporothrichosis. For invasive candidiasis, diagnostic methods must differentiate Candida colonization of mucous membranes or superficial infection from tissue invasion by this microorganism. Substantial progress has been made in diagnosis of invasive candidiasis with the development of a variety of methods for the detection of antibodies and antigens. However, no single test has found widespread clinical use and there is a consensus that diagnosis based on a single specimen lacks sensitivity. It is necessary to test sequential samples taken while the patient is at greatest risk for developing invasive candidiasis to optimize the diagnosis. Results obtained from a panel of diagnostic tests in association with clinical aspects will likely be the most useful strategy for early diagnosis and therapy.

  6. Integrated rapid-diagnostic-test reader platform on a cellphone.

    Science.gov (United States)

    Mudanyali, Onur; Dimitrov, Stoyan; Sikora, Uzair; Padmanabhan, Swati; Navruz, Isa; Ozcan, Aydogan

    2012-08-07

    We demonstrate a cellphone-based rapid-diagnostic-test (RDT) reader platform that can work with various lateral flow immuno-chromatographic assays and similar tests to sense the presence of a target analyte in a sample. This compact and cost-effective digital RDT reader, weighing only ~65 g, mechanically attaches to the existing camera unit of a cellphone, where various types of RDTs can be inserted to be imaged in reflection or transmission modes under light-emitting diode (LED)-based illumination. Captured raw images of these tests are then digitally processed (within less than 0.2 s per image) through a smart application running on the cellphone for validation of the RDT, as well as for automated reading of its diagnostic result. The same smart application then transmits the resulting data, together with the RDT images and other related information (e.g., demographic data), to a central server, which presents the diagnostic results on a world map through geo-tagging. This dynamic spatio-temporal map of various RDT results can then be viewed and shared using internet browsers or through the same cellphone application. We tested this platform using malaria, tuberculosis (TB) and HIV RDTs by installing it on both Android-based smartphones and an iPhone. Providing real-time spatio-temporal statistics for the prevalence of various infectious diseases, this smart RDT reader platform running on cellphones might assist healthcare professionals and policymakers to track emerging epidemics worldwide and help epidemic preparedness.

  7. A Novel Automatic Rapid Diagnostic Test Reader Platform

    Science.gov (United States)

    Ozkan, Haydar; Kayhan, Osman Semih

    2016-01-01

    A novel automatic Rapid Diagnostic Test (RDT) reader platform is designed to analyze and diagnose target disease by using existing consumer cameras of a laptop-computer or a tablet. The RDT reader is useable with numerous lateral immunochromatographic assays and similar biomedical tests. The system has two different components, which are 3D-printed, low-cost, tiny, and compact stand and a decision program named RDT-AutoReader 2.0. The program takes the image of RDT, crops the region of interest (ROI), and extracts the features from the control end test lines to classify the results as invalid, positive, or negative. All related patient's personal information, image of ROI, and the e-report are digitally saved and transferred to the related clinician. Condition of the patient and the progress of the disease can be monitored by using the saved data. The reader platform has been tested by taking image from used cassette RDTs of rotavirus (RtV)/adenovirus (AdV) and lateral flow strip RDTs of Helicobacter pylori (H. pylori) before discarding them. The created RDT reader can also supply real-time statistics of various illnesses by using databases and Internet. This can help to inhibit propagation of contagious diseases and to increase readiness against epidemic diseases worldwide. PMID:27190549

  8. Use of rapid HIV assays as supplemental tests in specimens with repeatedly reactive screening immunoassay results not confirmed by HIV-1 Western blot.

    Science.gov (United States)

    Wesolowski, Laura G; Delaney, Kevin P; Meyer, William A; Blatt, Amy J; Bennett, Berry; Chavez, Pollyanna; Granade, Timothy C; Owen, Michele

    2013-09-01

    An alternate HIV testing algorithm has been proposed which includes a fourth-generation immunoassay followed by an HIV-1/HIV-2 antibody differentiation supplemental test for reactive specimens and a nucleic acid test (NAT) for specimens with discordant results. To evaluate the performance of five rapid tests (Alere Clearview, Bio-Rad Multispot, OraSure OraQuick, MedMira Reveal, and Trinity Biotech Unigold) as the supplemental antibody assay in the algorithm. A total of 3273 serum and plasma specimens that were third-generation immunoassay repeatedly reactive and Western blot (WB) negative or indeterminate were tested with rapid tests and NAT. Specimens were classified by NAT: (1) HIV-1 infected (NAT-reactive; n=184, 5.6%), (2) HIV-status unknown (NAT nonreactive; n=3078, 94.2%) or by Multispot, (3) HIV-2 positive (n=5), and (4) HIV-1 and HIV-2 positive (n=6). Excluding HIV-2 positive specimens, we calculated the proportion of reactive rapid tests among specimens with reactive and nonreactive NAT. The proportion of infected specimens with reactive rapid test results and negative or indeterminate WB ranged from 30.4% (56) to 47.8% (88) depending on the rapid test. From 1% to 2% of NAT-negative specimens had reactive rapid test results. In these diagnostically challenging specimens, all rapid tests identified infections that were missed by the Western blot, but only Multispot could differentiate HIV-1 from HIV-2. Regardless of which rapid test is used as a supplemental test in the alternative algorithm, false-positive algorithm results (i.e., reactive screening and rapid test in uninfected person) may occur, which will need to be resolved during the baseline medical evaluation. Published by Elsevier B.V.

  9. Evaluation of a direct immunofluorescent antibody (difma test using Leishmania genus - specific monoclonal antibody in the routine diagnosis of cutaneous leishmaniasis

    Directory of Open Access Journals (Sweden)

    Martha E. Chico

    1995-06-01

    Full Text Available A direct immunofluorescent antibody (DIFMA test using a Leishmania genus- specific monoclonal antibody was evaluated in the routine diagnosis of cutaneous leishmaniasis (CL in Ecuador. This test was compared with the standard diagnostic techniques of scrapings, culture and histology. Diagnostic samples were taken from a total of 90 active dermal ulcers from patients from areas of Ecuador known to be endemic for cutaneous leishmaniasis. DIFMA was positive in all lesions. It was shown to be significantly superior to standard diagnostic methods either alone or in combination. The sensitivity of DIFMA did not diminish with chronicity of lesions. This test proved to be extremely useful in the routine diagnosis of CL because it is highly sensitive, is easy to use and produces rapid results.O método de imunofluorescência direta (DIFMA, com anticorpos monoclonais gênero- específicos para Leishmania, foi avaliado na rotina diagnostica da leishmaniose cutânea no Equador. O método foi comparado com técnicas diagnosticas de rotina: o esfregaço, a cultura e o exame histopatolôgico. As amostras para o diagnóstico foram obtidas de um total de 90 lesões cutâneas ativas, de doentes das ãreas do Equador, endêmicas para leishmaniose cutânea. O DIFMA foi positivo em todas as lesões, com resultados significativamente superior aos métodos diagnósticos de rotina, isolado ou em combinação. A sensibilidade do DFIMA não diminui em lesões crônicas. O método mostra-se muito útil no diagnóstico de leishmaniose cutânea, pela sua sensibilidade, rapidez e facilidade de execução.

  10. Comparison of Four Serological Tests for Detecting Antibodies to Japanese Encephalitis Virus after Vaccination in Children

    Science.gov (United States)

    Cha, Go Woon; Cho, Jung Eun; Ju, Young Ran; Hong, Young-Jin; Han, Myung Guk; Lee, Won-Ja; Choi, Eui Yul; Jeong, Young Eui

    2014-01-01

    Objectives Several different methods are currently used to detect antibodies to Japanese encephalitis virus (JEV) in serum samples or cerebrospinal fluid. These methods include the plaque reduction neutralization test (PRNT), the hemagglutination inhibition (HI) test, indirect immunofluorescence assay (IFA), and enzyme-linked immunosorbent assay (ELISA). The purpose of this study was to compare the performance of each method in detecting vaccine-induced antibodies to JEV. Methods The study included 29 children who had completed a primary immunization schedule with an inactivated vaccine against JEV derived from mouse brain (n = 15) or a live attenuated SA14-14-2 vaccine (n = 14). Serum samples were collected between 3 months and 47 months after the last immunization. The serum samples were tested by performing the PRNT, HI test, in-house IFA, and commercial ELISA. The antibody detection rates were compared between tests. Results All 29 serum samples were positive with the PRNT, showing antibody titers from 1:20 to 1:2560. The HI test showed positive rates of 86.7% (13/15) and 71.4% (10/14) in the inactivated and live attenuated vaccine groups, respectively. The results of the IFA for immunoglobulin (Ig)G were positive in 53.3% (8/15) of children in the inactivated vaccine group and 35.7% (5/14) in the live attenuated vaccine group. Neither the IFA nor ELISA detected JEV IgM antibodies in any of the 29 children. Conclusion These results show that detection rates of vaccine-induced antibodies to JEV have a wide range (0–100%) depending on the testing method as well as the time since immunization and individual differences between children. These findings are helpful in interpreting serological test results for the diagnosis of Japanese encephalitis in situations where vaccines are widely administered. PMID:25389515

  11. Diagnostic value of animal-side antibody assays for rapid detection of Mycobacterium bovis or Mycobacterium microti infection in South American camelids.

    Science.gov (United States)

    Lyashchenko, Konstantin P; Greenwald, Rena; Esfandiari, Javan; Rhodes, Shelley; Dean, Gillian; de la Rua-Domenech, Ricardo; Meylan, Mireille; Vordermeier, H Martin; Zanolari, Patrik

    2011-12-01

    Tuberculosis (TB) in South American camelids (SAC) is caused by Mycobacterium bovis or Mycobacterium microti. Two serological methods, rapid testing (RT) and the dual-path platform (DPP) assay, were evaluated using naturally infected SAC. The study population included 156 alpacas and 175 llamas in Great Britain, Switzerland, and the United States. TB due to M. bovis (n = 44) or M. microti (n = 8) in 35 alpacas and 17 llamas was diagnosed by gross pathology examination and culture. Control animals were from herds with no TB history. The RT and the DPP assay showed sensitivities of 71% and 74%, respectively, for alpacas, while the sensitivity for llamas was 77% for both assays. The specificity of the DPP assay (98%) was higher than that of RT (94%) for llamas; the specificities of the two assays were identical (98%) for alpacas. When the two antibody tests were combined, the parallel-testing interpretation (applied when either assay produced a positive result) enhanced the sensitivities of antibody detection to 89% for alpacas and 88% for llamas but at the cost of lower specificities (97% and 93%, respectively), whereas the serial-testing interpretation (applied when both assays produced a positive result) maximized the specificity to 100% for both SAC species, although the sensitivities were 57% for alpacas and 65% for llamas. Over 95% of the animals with evidence of TB failed to produce skin test reactions, thus confirming concerns about the validity of this method for testing SAC. The findings suggest that serological assays may offer a more accurate and practical alternative for antemortem detection of camelid TB.

  12. Diagnostic Value of Animal-Side Antibody Assays for Rapid Detection of Mycobacterium bovis or Mycobacterium microti Infection in South American Camelids▿

    Science.gov (United States)

    Lyashchenko, Konstantin P.; Greenwald, Rena; Esfandiari, Javan; Rhodes, Shelley; Dean, Gillian; de la Rua-Domenech, Ricardo; Meylan, Mireille; Vordermeier, HMartin; Zanolari, Patrik

    2011-01-01

    Tuberculosis (TB) in South American camelids (SAC) is caused by Mycobacterium bovis or Mycobacterium microti. Two serological methods, rapid testing (RT) and the dual-path platform (DPP) assay, were evaluated using naturally infected SAC. The study population included 156 alpacas and 175 llamas in Great Britain, Switzerland, and the United States. TB due to M. bovis (n = 44) or M. microti (n = 8) in 35 alpacas and 17 llamas was diagnosed by gross pathology examination and culture. Control animals were from herds with no TB history. The RT and the DPP assay showed sensitivities of 71% and 74%, respectively, for alpacas, while the sensitivity for llamas was 77% for both assays. The specificity of the DPP assay (98%) was higher than that of RT (94%) for llamas; the specificities of the two assays were identical (98%) for alpacas. When the two antibody tests were combined, the parallel-testing interpretation (applied when either assay produced a positive result) enhanced the sensitivities of antibody detection to 89% for alpacas and 88% for llamas but at the cost of lower specificities (97% and 93%, respectively), whereas the serial-testing interpretation (applied when both assays produced a positive result) maximized the specificity to 100% for both SAC species, although the sensitivities were 57% for alpacas and 65% for llamas. Over 95% of the animals with evidence of TB failed to produce skin test reactions, thus confirming concerns about the validity of this method for testing SAC. The findings suggest that serological assays may offer a more accurate and practical alternative for antemortem detection of camelid TB. PMID:22012976

  13. Rapid screening test for detection of oxytetracycline residues in milk using lateral flow assay.

    Science.gov (United States)

    Naik, Laxmana; Sharma, Rajan; Mann, Bimlesh; Lata, Kiran; Rajput, Y S; Surendra Nath, B

    2017-03-15

    A rapid, semi-quantitative lateral flow assay (LFA) was developed to screen the oxytetracycline (OTC) antibiotics residues in milk samples. In this study a competitive immuno-assay format was established. Colloidal gold nano-particles (GNP) were prepared and used as labelling material in LFA. Polyclonal antibodies were generated against OTC molecule (anti-OTC), purified and the quality was assessed by enzyme linked immuno sorbet assay. For the first time membrane components required for LFA in milk system was optimized. GNP and anti-OTC stable conjugate preparation method was standardized, and then these components were placed over the conjugate pad. OTC coupled with carrier protein was placed on test line; species specific secondary antibodies were placed on the control line of the membrane matrix. Assay was validated by spiking OTC to antibiotic free milk samples and results could be accomplished within 5min. without need of any equipment. The visual detection limit was 30ppb. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Parvovirus antibodies in vaccinated gilts in field conditions--results with HI and ELISA tests.

    Science.gov (United States)

    Oravainen, J; Hakala, M; Rautiainen, E; Veijalainen, P; Heinonen, M; Tast, A; Virolainen, J V; Peltoniemi, O A T

    2006-02-01

    This study was conducted to determine the antibody response for porcine parvovirus (PPV) of 39 gilts in field conditions after vaccination. Gilts from four herds endemically infected with PPV were injected twice with a commercial vaccine of inactivated PPV and Erysipelothrix rhusiopathiae. The PPV antibodies were analysed both with haemagglutination inhibition (HI) and enzyme-linked immunosorbent assay (ELISA) in order to study the agreement between these methods. The possible association between high-antibody titres and reproductive failure (repeat breeding, culling for infertility, gilts (84.6%) had not seroconverted by the age of 6 months. On-field vaccination resulted in a consistent increase of humoral immunity not exceeding the antibody level of 1 : 512 in the majority of gilts in all herds examined. The agreement between ELISA and HI tests was moderate (Spearman's rho = 0.87, kappa = 0.63). The seroconversion over the level >1:512 by mid-pregnancy was not associated with reproductive failure.

  15. An audit on HIV antibody test uptake amongst GUM clinic attendees in the West Midland region.

    Science.gov (United States)

    Das, Satyajit; Huengsberg, Mia; Natin, Dan; Walzman, Mike

    2004-08-01

    We audited the practice of offering, and the uptake of, an HIV antibody test amongst genitourinary medicine clinic patients in the West Midlands region. There were wide variations in the offering (from 14 to 100%) and uptake (18 to 64%) of the test in the different clinics within the same region.

  16. Accuracy of diagnostic antibody tests for coeliac disease in children

    DEFF Research Database (Denmark)

    Giersiepen, Klaus; Lelgemann, Monika; Stuhldreher, Nina

    2012-01-01

    The aim of this study was to summarise the evidence from 2004 to September 2009 on the performance of laboratory-based serological and point of care (POC) tests for diagnosing coeliac disease (CD) in children using histology as reference standard.......The aim of this study was to summarise the evidence from 2004 to September 2009 on the performance of laboratory-based serological and point of care (POC) tests for diagnosing coeliac disease (CD) in children using histology as reference standard....

  17. THE INVESTIGATION OF BRUCELLA ANTIBODY WITH MILK RING TEST AND AGGLUTINATION TEST IN MILK COLLECTED FROM SAMSUN REGION

    Directory of Open Access Journals (Sweden)

    Goknur TERZI

    2006-06-01

    Full Text Available In this study Brucella antibodies were investigated with agglutination test (Whey-AT and Milk Ring Test (MRT in a total of 100 milk samples as 50 of cow milk and 50 of goat milk collected from center and villages of Samsun. According to MRT Brucella antibodies was positive at 10 samples (20 % of cow milk and 6 samples (12 % of goat milk. In cow milk, 4 (8 % positive, 3 (6 % suspicious and 43 (86 % negative samples; in goat milk 3 (6 % positive, 2 (4 % suspicious and 45 (90 % negative samples were determined according to antibodies titre of serum agglutination test (Whey-AT. [TAF Prev Med Bull 2006; 5(3.000: 196-203

  18. Comparative efficacy of antigen and antibody detection tests for human trichinellosis

    Energy Technology Data Exchange (ETDEWEB)

    Ivanoska, D.; Cuperlovic, K.; Gamble, H.R.; Murrell, K.D.

    1989-02-01

    Sera collected from patients with suspected or confirmed exposure to Trichinella spiralis were tested for circulating parasite antigens and antiparasite antibodies. Using an immunoradiometric assay, excretory--secretory antigens from muscle-stage larvae of T. spiralis were detected in the sera of 47% of 62 patients with clinical trichinellosis and 13% of 39 patients without clinical signs but suspected of exposure to infected meat. In comparison, antibodies were detected using an indirect immunofluorescent test in the circulation of 100% of the 62 patients with clinical trichinellosis and 46% of the 39 patients with suspected exposure. The presence of antibodies specific to excretory-secretory products of T. spiralis muscle larvae was confirmed in the majority of the samples tested by a monoclonal antibody-based competitive inhibition assay. These results indicate that antibody detection is a more sensitive diagnostic method for human trichinellosis, but that antigen detection might be a useful confirmatory test because it is a direct demonstration of parasite products in the circulation.

  19. Identifying HIV infection in South African women: How does a fourth generation HIV rapid test perform?

    Directory of Open Access Journals (Sweden)

    Kapila Bhowan

    2011-12-01

    Full Text Available Background: HIV rapid tests (RT play an important role in tackling the HIV pandemic in South Africa. Third generation RT that detect HIV antibodies are currently used to diagnose HIV infection at the point of care. Determine Combo (DC is the first fourth generation RT that detects both p24 antigen (p24Ag and HIV antibodies (Ab, theoretically reducing the window period and increasing detection rates. Early detection of maternal HIV infection is important to mitigate the high risk of vertical transmission associated with acute maternal infection. Objectives: We assessed the performance of the DC RT against third generation RT in antenatal and post-partum women. Methods: Third generation RT Advance Quality and Acon were used in a serial algorithm to diagnose HIV infection in antenatal and post-partum women over six months at a tertiary hospital in Johannesburg, South Africa. This data provided the reference against which the DC RT was compared on plasma and whole blood samples. Results: The 1019 participants comprised 345 (34% antenatal and 674 (66% post-partum women. Ninety women (8.8% tested HIV-positive of whom 59 (66% were tested antenatally, and 31 (34% post-partum yielding prevalence rates of 17.1% and 4.6% respectively. The sensitivity and specificity of the Ab component of DC on plasma antenatally was 100% (93.8% – 100% and 100% (98.6% – 100% respectively and post-partum was 100% (88.9% – 100% and 99.6% (98.8% – 99.9% respectively. One false positive and not a single true positive p24Ag was detected. Of 505 post-partum women who tested HIV-negative 6–12 months prior to enrolment, 12 (2.4% seroconverted. Conclusion: The fourth generation DC offered no advantage over current third generation RT in the diagnosis of HIV infection.

  20. [Rapid diagnostic tests for the serodiagnosis of human cystic echinococcosis].

    Science.gov (United States)

    Tamarozzi, F; Mariconti, M; Covini, I; Brunetti, E

    2017-02-01

    Cystic echinococcosis (CE) is a parasitic zoonosis especially affecting resource-poor populations in livestock raising areas. Imaging, in particular ultrasound (US), is crucial for the diagnosis, staging, and clinical management of abdominal CE in humans. Serology is a valuable complement to imaging, especially when ultrasound features of CE are absent or unclear. In rural endemic areas, where expertise in US is scant, and conventional serology techniques are unavailable due to lack of laboratory equipment, rapid diagnostic tests (RDTs) may be very useful. Several reports have described the performance of commercial and experimental RDTs in the diagnosis of CE, including a recent study by our group that compared the diagnostic performances of three commercial RDTs for the diagnosis of hepatic CE. To put RDTs for CE in context, we reviewed the available literature in English on this topic. Overall, RDTs appear to be useful in resourcepoor settings where they may replace conventional serodiagnostic tests. However, like other serodiagnostic tests, RDTs lack standardization and show unsatisfactory sensitivity and specificity. An important issue that needs to be addressed is that studies on the diagnostic performance of RDTs fail to take into account the variables known to influence results such as anatomical location and cyst stage.

  1. [Viral load test conducive to excluding negative subjects from suspects in HIV antibody detections].

    Science.gov (United States)

    Hei, Fa-Xin; Zhang, Qi-Yun; Sun, Wei-Dong; Zhang, Qin; Ye, Jing-Rong; Liu, Hai-Lin; Lu, Hong-Yan

    2008-01-01

    To study whether plasma viral load testing is helpful to exclude ones free from Human immunodeficiency virus (HIV) infections from suspects in HIV antibody detections. 19 Specimens, which showed disconcordant results of the two HIV EIA testing (S/CO test, were selected. Viral load of the specimens were detected. A six-month follow up survey in detecting HIV antibody was conducted in these subjects. None of these 19 cases was observed to be positive HIV viral loads and there was no any progress in WB bands development during the follow-up period. The possibility of HIV infection could be excluded. When the specimens react with very low intensity in both EIA and WB, negative viral load result is conducive to exclude negative subjects from suspects in HIV antibody detections.

  2. A novel non-rapid-eye movement and rapid-eye-movement parasomnia with sleep breathing disorder associated with antibodies to IgLON5: a case series, characterisation of the antigen, and post-mortem study.

    Science.gov (United States)

    Sabater, Lidia; Gaig, Carles; Gelpi, Ellen; Bataller, Luis; Lewerenz, Jan; Torres-Vega, Estefanía; Contreras, Angeles; Giometto, Bruno; Compta, Yaroslau; Embid, Cristina; Vilaseca, Isabel; Iranzo, Alex; Santamaría, Joan; Dalmau, Josep; Graus, Francesc

    2014-06-01

    Autoimmunity might be associated with or implicated in sleep and neurodegenerative disorders. We aimed to describe the features of a novel neurological syndrome associated with prominent sleep dysfunction and antibodies to a neuronal antigen. In this observational study, we used clinical and video polysomnography to identify a novel sleep disorder in three patients referred to the Sleep Unit of Hospital Clinic, University of Barcelona, Spain, for abnormal sleep behaviours and obstructive sleep apnoea. These patients had antibodies against a neuronal surface antigen, which were also present in five additional patients referred to our laboratory for antibody studies. These five patients had been assessed with polysomnography, which was done in our sleep unit in one patient and the recording reviewed in a second patient. Two patients underwent post-mortem brain examination. Immunoprecipitation and mass spectrometry were used to characterise the antigen and develop an assay for antibody testing. Serum or CSF from 298 patients with neurodegenerative, sleep, or autoimmune disorders served as control samples. All eight patients (five women; median age at disease onset 59 years [range 52-76]) had abnormal sleep movements and behaviours and obstructive sleep apnoea, as confirmed by polysomnography. Six patients had chronic progression with a median duration from symptom onset to death or last visit of 5 years (range 2-12); in four the sleep disorder was the initial and most prominent feature, and in two it was preceded by gait instability followed by dysarthria, dysphagia, ataxia, or chorea. Two patients had a rapid progression with disequilibrium, dysarthria, dysphagia, and central hypoventilation, and died 2 months and 6 months, respectively, after symptom onset. In five of five patients, video polysomnography showed features of obstructive sleep apnoea, stridor, and abnormal sleep architecture (undifferentiated non-rapid-eye-movement [non-REM] sleep or poorly structured

  3. Reactivity of routine HIV antibody tests in children who initiated antiretroviral therapy in early infancy as part of the Children with HIV Early Antiretroviral Therapy (CHER) trial

    Science.gov (United States)

    Payne, H; Mkhize, NN; Otwombe, K; Lewis, J; Panchia, R; Callard, R; Morris, L; Babiker, A; Violari, A; Cotton, MF; Klein, N; Gibb, DM

    2015-01-01

    Background Early ART and virological suppression may impact on evolving antibody responses to HIV-infection. We evaluated frequency and predictors of seronegativity in infants starting early ART. Methods HIV-antibody results were compared between two of three arms of the Children with HIV Early Antiretroviral Therapy (CHER) trial: HIV-infected infants aged HIV-infection was diagnosed by DNA PCR and RNA >1000 copies/ml. ART started at median age 7 and 23 weeks respectively. Antibody was measured from all available stored samples, ART-96W (n=109) and ART-Def (n=75), at trial week 84 (median age 92 (IQR 90.6–93.4) weeks) using 3 assays: 4th generation EIA HIV-antigen/antibody combination; HIV-1/2 rapid-antibody test and quantitative anti-gp120 IgG ELISA. Findings More ART-96W were seronegative than ART-Def by EIA (46% versus 11%, ptest (53% versus 14%, p24 weeks were seropositive. Cumulative viral load to week 84 correlated with anti-gp120 IgG levels (coefficient=0.54, pHIV-seronegative by at aged ∼2 years. HIV-antibody tests cannot be used to re-confirm HIV-diagnosis in children starting early-ART. Long-term consequences of seronegativity need further study. Funding Wellcome Trust, Medical Research Council, National Institutes of Health. PMID:26043884

  4. Validating a Rapid, Automated Test of Spatial Release From Masking.

    Science.gov (United States)

    Jakien, Kasey M; Kampel, Sean D; Stansell, Meghan M; Gallun, Frederick J

    2017-09-21

    age only reached significance for colocated conditions. The SR2 is a reliable and effective method of testing spatial release from masking, suitable for screening abnormal listening abilities and for tracking rehabilitation over time. Future work should focus on developing and validating rapid, automated testing to identify the ability of listeners to benefit from high-frequency amplification, smaller spatial separations, and larger spectral differences among talkers.

  5. Rapid comparison of a candidate biosimilar to an innovator monoclonal antibody with advanced liquid chromatography and mass spectrometry technologies.

    Science.gov (United States)

    Xie, Hongwei; Chakraborty, Asish; Ahn, Joomi; Yu, Ying Qing; Dakshinamoorthy, Deepalakshmi P; Gilar, Martin; Chen, Weibin; Skilton, St John; Mazzeo, Jeffery R

    2010-01-01

    This study shows that state-of-the-art liquid chromatography (LC) and mass spectrometry (MS) can be used for rapid verification of identity and characterization of sequence variants and posttranslational modifications (PTMs) for antibody products. A candidate biosimilar IgG1 monoclonal antibody (mAb) was compared in detail to a commercially available innovator product. Intact protein mass, primary sequence, PTMs, and the micro-differences between the two mAbs were identified and quantified simultaneously. Although very similar in terms of sequences and modifications, a mass difference observed by LC-MS intact mass measurements indicated that they were not identical. Peptide mapping, performed with data independent acquisition LC-MS using an alternating low and elevated collision energy scan mode (LC-MS(E)), located the mass difference between the biosimilar and the innovator to a two amino acid residue variance in the heavy chain sequences. The peptide mapping technique was also used to comprehensively catalogue and compare the differences in PTMs of the biosimilar and innovator mAbs. Comprehensive glycosylation profiling confirmed that the proportion of individual glycans was different between the biosimilar and the innovator, although the number and identity of glycans were the same. These results demonstrate that the combination of accurate intact mass measurement, released glycan profiling, and LC-MS(E) peptide mapping provides a set of routine tools that can be used to comprehensively compare a candidate biosimilar and an innovator mAb.

  6. Rapid Transient Production of a Monoclonal Antibody Neutralizing the Porcine Epidemic Diarrhea Virus (PEDV) in Nicotiana benthamiana and Lactuca sativa.

    Science.gov (United States)

    Rattanapisit, Kaewta; Srijangwad, Anchalee; Chuanasa, Taksina; Sukrong, Suchada; Tantituvanont, Angkana; Mason, Hugh S; Nilubol, Dachrit; Phoolcharoen, Waranyoo

    2017-12-01

    Porcine epidemic diarrhea virus (PEDV) causes acute diarrhea, vomiting, dehydration, weight loss, and high mortality rate in neonatal piglets. Porcine epidemic diarrhea (PED) has been reported in Europe, America, and Asia including Thailand. The disease causes substantial losses to the swine industry in many countries. Presently, there is no effective PEDV vaccine available. In this study, we developed a plant-produced monoclonal antibody (mAb) 2C10 as a prophylactic candidate to prevent the PEDV infection. Recently, plant expression systems have gained interest as an alternative for the production of antibodies because of many advantages, such as low production cost, lack of human and animal pathogen, large scalability, etc. The 2C10 mAb was transiently expressed in Nicotiana benthamiana and lettuce using geminiviral vector. After purification by protein A affinity chromatography, the antibody was tested for the binding and neutralizing activity against PEDV. Our result showed that the plant produced 2C10 mAb can bind to the virus and also inhibit PEDV infection in vitro . These results show excellent potential for a plant-expressed 2C10 as a PEDV prophylaxis and a diagnostic for PEDV infection. Georg Thieme Verlag KG Stuttgart · New York.

  7. Babesial antibody dynamics after cattle immunisation with live vaccines, measured with an indirect immunofluorescence test.

    Science.gov (United States)

    Guglielmone, A A; Lugaresi, C I; Volpogni, M M; Anziani, O S; Vanzini, V R

    1997-06-01

    The efficacy of vaccination of Argentinean cattle against babesiosis and anaplasmosis using live immunogens was tested to detect specific antibodies in samples obtained about 60 days after vaccination. Under these conditions a higher than expected proportion of cattle failed to show antibodies against Babesia bigemina. Therefore, a study was designed to evaluate if this failure was due to insensitivity of the routine test to detect antibodies to B. bigemina or to lack of infectivity of the live vaccine. Four groups (G) of cattle were each inoculated subcutaneously with 10 million Babesia bovis (vaccinal strain R1A), 10 million B. bigemina (vaccinal strain S1A) and 10 million Anaplasma centrale (strain M1). G1 and G2 consisted of ten Angus bulls 20-24 months old and ten Angus bulls 15-18 months old, respectively; G3 and G4 consisted of ten and 16 Holstein 1-month-old male calves, respectively. Blood samples were obtained on days 0, 10, 20, 30, 40, 50 and 60 after vaccination and the sera were analysed with an indirect immunofluorescent (IFA) test to detect antibodies to B. bovis (baseline dilution for a positive result 1:60) and B. bigemina (baseline dilution 1:120). Positive IFA titres were considered as evidence of the infectivity of the Babesia vaccinal strains contained in the vaccine. All Angus bulls were found positive to antibodies against both Babesia species, by day 20 (B. bovis) and day 30 (B. bigemina), whereas 10-25% of Holstein calves were negative throughout. The partial lack of vaccine infectivity in the calves was considered to be a consequence of innate resistance of young calves to Babesia. Antibody titres to B. bovis and B. bigemina declined by day 60 after vaccination. However, all cattle that were positive to B. bovis antibodies on day 50 were still positive to the IFA test 10 days later while 10%, 30% and 12% of cattle of G1, G2 and G3 that were positive to B. bigemina antibodies on day 50 after vaccination were found negative to the IFA test

  8. Diagnostic accuracy of tests to detect Hepatitis C antibody: a meta-analysis and review of the literature

    Directory of Open Access Journals (Sweden)

    Weiming Tang

    2017-11-01

    Full Text Available Abstract Background Although direct-acting antivirals can achieve sustained virological response rates greater than 90% in Hepatitis C Virus (HCV infected persons, at present the majority of HCV-infected individuals remain undiagnosed and therefore untreated. While there are a wide range of HCV serological tests available, there is a lack of formal assessment of their diagnostic performance. We undertook a systematic review and meta-analysis to evaluate he diagnostic accuracy of available rapid diagnostic tests (RDT and laboratory based EIA assays in detecting antibodies to HCV. Methods We used the PRISMA checklist and Cochrane guidance to develop our search protocol. The search strategy was registered in PROSPERO (CRD42015023567. The search focused on hepatitis C, diagnostic tests, and diagnostic accuracy within eight databases (MEDLINE, EMBASE, the Cochrane Central Register of Controlled Trials, Science Citation Index Expanded, Conference Proceedings Citation Index-Science, SCOPUS, Literatura Latino-Americana e do Caribe em Ciências da Saúde and WHO Global Index Medicus. Studies were included if they evaluated an assay to determine the sensitivity and specificity of HCV antibody (HCV Ab in humans. Two reviewers independently extracted data and performed a quality assessment of the studies using the QUADAS tool. We pooled test estimates using the DerSimonian-Laird method, by using the software R and RevMan. 5.3. Results A total of 52 studies were identified that included 52,673 unique test measurements. Based on five studies, the pooled sensitivity and specificity of HCV Ab rapid diagnostic tests (RDTs were 98% (95% CI 98-100% and 100% (95% CI 100-100% compared to an enzyme immunoassay (EIA reference standard. High HCV Ab RDTs sensitivity and specificity were observed across screening populations (general population, high risk populations, and hospital patients using different reference standards (EIA, nucleic acid testing, immunoblot. There

  9. Diagnostic accuracy of tests to detect Hepatitis C antibody: a meta-analysis and review of the literature.

    Science.gov (United States)

    Tang, Weiming; Chen, Wen; Amini, Ali; Boeras, Debi; Falconer, Jane; Kelly, Helen; Peeling, Rosanna; Varsaneux, Olivia; Tucker, Joseph D; Easterbrook, Philippa

    2017-11-01

    Although direct-acting antivirals can achieve sustained virological response rates greater than 90% in Hepatitis C Virus (HCV) infected persons, at present the majority of HCV-infected individuals remain undiagnosed and therefore untreated. While there are a wide range of HCV serological tests available, there is a lack of formal assessment of their diagnostic performance. We undertook a systematic review and meta-analysis to evaluate he diagnostic accuracy of available rapid diagnostic tests (RDT) and laboratory based EIA assays in detecting antibodies to HCV. We used the PRISMA checklist and Cochrane guidance to develop our search protocol. The search strategy was registered in PROSPERO (CRD42015023567). The search focused on hepatitis C, diagnostic tests, and diagnostic accuracy within eight databases (MEDLINE, EMBASE, the Cochrane Central Register of Controlled Trials, Science Citation Index Expanded, Conference Proceedings Citation Index-Science, SCOPUS, Literatura Latino-Americana e do Caribe em Ciências da Saúde and WHO Global Index Medicus. Studies were included if they evaluated an assay to determine the sensitivity and specificity of HCV antibody (HCV Ab) in humans. Two reviewers independently extracted data and performed a quality assessment of the studies using the QUADAS tool. We pooled test estimates using the DerSimonian-Laird method, by using the software R and RevMan. 5.3. A total of 52 studies were identified that included 52,673 unique test measurements. Based on five studies, the pooled sensitivity and specificity of HCV Ab rapid diagnostic tests (RDTs) were 98% (95% CI 98-100%) and 100% (95% CI 100-100%) compared to an enzyme immunoassay (EIA) reference standard. High HCV Ab RDTs sensitivity and specificity were observed across screening populations (general population, high risk populations, and hospital patients) using different reference standards (EIA, nucleic acid testing, immunoblot). There were insufficient studies to undertake

  10. Erythrocyte adenosine transport. A rapid screening test for cardiovascular drugs.

    Science.gov (United States)

    Yeung, P K; Mosher, S J; Li, R; Farmer, P S; Klassen, G A; Pollak, P T; McMullen, M; Ferrier, G

    1993-11-01

    An erythrocyte (RBC) model based on whole blood was used to investigate the effect of cardiovascular drugs on the uptake of adenosine in vitro. Fresh whole blood obtained from healthy volunteers was allowed to equilibrate with various concentrations (5-1000 microM) of a tested agent. (2-3H)-Adenosine was used as a substrate, and the reaction was terminated after 2 sec of incubation at room temperature by rapid addition of a "Stopping Solution" which was a mixture of erythro-9-(2-hydroxy-3-nonyl)adenine, dipyridamole, and EDTA. The mixture was centrifuged (1760 g, 4 degrees C, 10 min), and the radioactivity of an aliquot of the supernatant was determined by a scintillation counter. The results showed that dipyridamole was the most potent agent tested (IC50 = 0.2 microM). Amongst the calcium antagonists studied, isradipine was most potent, followed by verapamil, clentiazem, diltiazem, and then nifedipine. The racemates of two metabolites of diltiazem, MX and MB, were more potent than the parent drug. The antiarrhythmic agents, amiodarone and sotalol, the two new lipid peroxidation inhibitors, U-74389F and U-78517F, and the anxiolytic agent, alprazolam, were as active as verapamil. The beta-receptor antagonist propranolol and the angiotensin converting enzyme (ACE) inhibitor, enalapril, were practically inactive. In addition, the model was stereoselective such that the S(-)-enantiomer of verapamil was considerably more potent than the R(+)-antipote, whereas d(+)-sotalol was practically inactive compared to racemic sotalol.

  11. Rapid Detection and Differentiation of Antibodies to HIV-1 and HIV-2 Using Multivalent Antigens and Magnetic Immunochromatography Testing▿

    Science.gov (United States)

    Granade, Timothy C.; Workman, Shon; Wells, Susan K.; Holder, Angela N.; Owen, S. Michele; Pau, Chou-Pong

    2010-01-01

    A simplified lateral-flow assay for the detection of antibodies to HIV using magnetic-bead conjugates and multibranched peptides from both HIV-1 and HIV-2 was developed. Magnetic immunochromatography testing (MICT) uses a standard lateral-flow platform that incorporates magnetic-bead conjugates for quantitative measurement of the magnetic field distortion associated with the bound magnetic conjugate (reported as adjusted relative magnetic units [MAR]). The results of the optimized MICT assay were compared to standard enzyme immunoassay (EIA) and Western blotting (WB) results using a blinded 649-member panel of specimens from the United States, Cameroon, and West Africa. The panel was comprised of samples from individuals infected with various HIV-1 subtypes (n = 234) or HIV-2 (n = 65) and HIV-seronegative specimens (n = 350). Additionally, 13 HIV-1 seroconversion panels (total specimens = 85), a worldwide panel containing seven of the major circulating HIV-1 subtypes (n = 18), an HIV-2 panel, an HIV-1/HIV-2 mixed panel, and 100 prospective specimens were tested with completely concordant results. Assay reproducibility (observed MAR) for both intra- and interrun testing was excellent, with coefficients of variation of HIV antibody status requiring no subjective interpretations. PMID:20410326

  12. Rapid cytometric antibiotic susceptibility testing utilizing adaptive multidimensional statistical metrics.

    Science.gov (United States)

    Huang, Tzu-Hsueh; Ning, Xinghai; Wang, Xiaojian; Murthy, Niren; Tzeng, Yih-Ling; Dickson, Robert M

    2015-02-03

    Flow cytometry holds promise to accelerate antibiotic susceptibility determinations; however, without robust multidimensional statistical analysis, general discrimination criteria have remained elusive. In this study, a new statistical method, probability binning signature quadratic form (PB-sQF), was developed and applied to analyze flow cytometric data of bacterial responses to antibiotic exposure. Both sensitive lab strains (Escherichia coli and Pseudomonas aeruginosa) and a multidrug resistant, clinically isolated strain (E. coli) were incubated with the bacteria-targeted dye, maltohexaose-conjugated IR786, and each of many bactericidal or bacteriostatic antibiotics to identify changes induced around corresponding minimum inhibition concentrations (MIC). The antibiotic-induced damages were monitored by flow cytometry after 1-h incubation through forward scatter, side scatter, and fluorescence channels. The 3-dimensional differences between the flow cytometric data of the no-antibiotic treated bacteria and the antibiotic-treated bacteria were characterized by PB-sQF into a 1-dimensional linear distance. A 99% confidence level was established by statistical bootstrapping for each antibiotic-bacteria pair. For the susceptible E. coli strain, statistically significant increments from this 99% confidence level were observed from 1/16x MIC to 1x MIC for all the antibiotics. The same increments were recorded for P. aeruginosa, which has been reported to cause difficulty in flow-based viability tests. For the multidrug resistant E. coli, significant distances from control samples were observed only when an effective antibiotic treatment was utilized. Our results suggest that a rapid and robust antimicrobial susceptibility test (AST) can be constructed by statistically characterizing the differences between sample and control flow cytometric populations, even in a label-free scheme with scattered light alone. These distances vs paired controls coupled with rigorous

  13. CHO-S antibody titers >1 gram/liter using flow electroporation-mediated transient gene expression followed by rapid migration to high-yield stable cell lines.

    Science.gov (United States)

    Steger, Krista; Brady, James; Wang, Weili; Duskin, Meg; Donato, Karen; Peshwa, Madhusudan

    2015-04-01

    In recent years, researchers have turned to transient gene expression (TGE) as an alternative to CHO stable cell line generation for early-stage antibody development. Despite advances in transfection methods and culture optimization, the majority of CHO-based TGE systems produce insufficient antibody titers for extensive use within biotherapeutic development pipelines. Flow electroporation using the MaxCyte STX Scalable Transfection System is a highly efficient, scalable means of CHO-based TGE for gram-level production of antibodies without the need for specialized expression vectors or genetically engineered CHO cell lines. CHO cell flow electroporation is easily scaled from milligram to multigram quantities without protocol reoptimization while maintaining transfection performance and antibody productivity. In this article, data are presented that demonstrate the reproducibility, scalability, and antibody production capabilities of CHO-based TGE using the MaxCyte STX. Data show optimization of posttransfection parameters such as cell density, media composition, and feed strategy that result in secreted antibody titers >1 g/L and production of multiple grams of antibody within 2 weeks of a single CHO-S cell transfection. In addition, data are presented to demonstrate the application of scalable electroporation for the rapid generation of high-yield stable CHO cell lines to bridge the gap between early- and late-stage antibody development activities. © 2014 Society for Laboratory Automation and Screening.

  14. Detection of antibody against limax amoebae by means of the indirect haemagglutination test.

    Science.gov (United States)

    Cerva, L

    1977-01-01

    A detailed description is given of the procuedure of the indirect haemagglutination test employed in the detection of specific antibodies against pathogenic amoebae of the genera Naegleria and Acanthamoeba. The preservation of all ingredients obtained by lyophilisation provide for a standard pattern of the test. The results of the test with experimentally prepared immune rabbit sera demonstrate an antigenic uniformity of the various isolates of Naegleria fowleri, and their marked difference from Acanthamoeba.

  15. Urine antibody tests: new insights into the dynamics of HIV-1 infection.

    Science.gov (United States)

    Urnovitz, H B; Sturge, J C; Gottfried, T D; Murphy, W H

    1999-09-01

    Noninvasive methodologies provide alternatives to diagnostic blood tests and have high patient acceptance, increased safety, and reduced costs. Such tests may supplement or replace blood diagnostic assays currently in use. Using a licensed urine-based test for antibody to HIV-1, we performed 25 991 HIV-1 urine antibody enzyme immunoassay (EIA) screening tests [confirmable by HIV-1 Western blot (WB)] on paired urine and blood specimens obtained from high- and low-risk HIV-1 subjects collected at six sites representative of the US population. Using HIV-1 urine EIA tests confirmed by urine Western blot, a compartmentalized immune response (urine positive/serum negative) occurred in 0.24% of a cohort of 11 896 subjects. In the same cohort, specimens that were urine negative/serum positive occurred in 0.17% of subjects. In a second study of 25 991 subjects that included 859 high-risk individuals, the false-positive urine EIA frequency (urine WB negative or indeterminate) was 1.3%. This false-positive frequency in the high-risk cohort was attributed, in part, to an IgA antibody response. We tabulated urine and serum indeterminate reactivities and examined their possible causes. Data are presented showing that antibodies from a seroindeterminate HIV-1vau group O subject were reactive in urine EIA and urine WB tests. An analysis of the HIV-1vau strain group O env nucleotide sequence disclosed a high frequency of homology with human chromosome 7q31, a fragile site implicated in many human malignancies. These results demonstrate the utility of urine for alternative HIV-1 antibody testing and provide new insights into the pathogenesis of HIV-1 infection and into potential application of this approach in investigation of other microbial pathogens and toxic compounds.

  16. [Evaluation of an immunochromatographic fourth generation test for the rapid diagnosis of acute HIV infection].

    Science.gov (United States)

    Kawahata, Takuya; Nagashima, Mami; Sadamasu, Kenji; Kojima, Yoko; Mori, Haruyo

    2013-07-01

    The early diagnosis of human immunodeficiency virus (HIV) infection is important to provide effective antiviral treatment and to prevent transmission of HIV. One of the key issues to achieve this goal is to shorten the so-called "diagnostic window period" when the humoral immune response toward the virus is not fully developed during the acute phase of HIV-1 infection. In 2008, the Espline HIV Ag/Ab test kit (E4G, Fujirebio Inc. Japan) was marketed in Japan belonging to the fourth generation of HIV test kits characterized by its ability to detect both viral antigens (Ag) and anti-HIV-1/2 antibodies (Ab). E4G is the first and only fourth generation immunochromatographic HIV test kit approved in Japan at present. To evaluate its performance to diagnose acute HIV infection (AHI), E4G was compared with fourth generation Ag/Ab ELISA test kits, a third generation PA test kit, WB and real-time PCR for the testing of 25 AHI clinical specimens. E4G detected HIV infection in 18/25 specimens (sensitivity : 72.0%), of which the viral Ag was detected in only 2 specimens (8.0%) bearing a viral load > 10 million copies/mL. No spesimens were simultaneously reactive to both Ag and Ab against HIV. The third generation PA achieved a positive score of 17/ 25 specimens (68.0%), which was almost the same as the E4G figure. In contrast the fourth generation Ag/ Ab ELISA scored all the 25 AHI specimens positive (sensitivity : 100%). Overall, although having the merit of offering a rapid diagnostic test for HIV infection, E4G does not provide a sensitivity in AHI diagnosis superior to test kits currently available.

  17. Performance evaluation of the point-of-care INSTI™ HIV-1/2 antibody test in early and established HIV infections.

    Science.gov (United States)

    Adams, Sarah; Luo, Wei; Wesolowski, Laura; Cohen, Stephanie E; Peters, Philip J; Owen, S Michele; Masciotra, Silvina

    2017-06-01

    The flow-through INSTI™ HIV-1/HIV-2 Rapid Antibody (INSTI) test is a 60s FDA-approved test for HIV-1 and HIV-2 antibody testing using whole blood and plasma. We evaluated the performance of INSTI using plasma and simulated whole blood specimens. INSTI's performance in plasma specimens from commercial seroconversion panels was assessed by estimating the relative sensitivity using a 50% cumulative frequency analysis and by comparing its performance with other FDA-approved rapid tests (RTs). INSTI was further evaluated using 320 HIV-1 plasma specimens collected during a cross-sectional study and with 107 HIV-1 and 24 HIV-2 simulated whole blood specimens. Sensitivity and specificity were calculated using 615 known HIV-1 group M/O and 80 HIV-2 (Western blot (WB)-positive), and 497 HIV-negative plasma specimens, respectively. In HIV-1 seroconversion panels, INSTI became reactive 9days before a positive WB. When compared to FDA-approved antibody-based lateral flow RTs, INSTI detected significantly more early infections. Among HIV-1-infected cross-sectional plasma samples, INSTI detected 23 (27%) of 85 Architect-positive/Multispot-negative or indeterminate specimens. For plasma specimens, the sensitivity was 99.84% for HIV-1 and 100% for HIV-2, and the specificity was 99.80%. Using simulated whole blood from seroconverters, INSTI performed similarly to plasma. INSTI performed significantly better than antibody-based lateral flow RTs during early stages of seroconversion. Sensitivity and specificity were within the manufacturer's reported ranges. Considering the observed test performance and the almost immediate results, INSTI is an accurate option to detect HIV-1/HIV-2 antibodies in point-of-care settings where lab testing is not feasible. Published by Elsevier B.V.

  18. Bulk tank milk ELISA for detection of antibodies to Mycobacterium avium subsp paratuberculosis: Correlation between repeated tests and within-herd antibody-prevalence

    DEFF Research Database (Denmark)

    Nielsen, Søren Saxmose; Toft, Nils

    2014-01-01

    Detection of bulk tank milk (BTM) antibodies using ELISA (BTM-ELISA) may constitute an inexpensive test for surveillance of Mycobacterium avium subsp. paratuberculosis (MAP) infection in dairy cattle herds provided that the test is accurate and consistent. The objectives of this study were...... Danish Holstein herds over a period of one year. All samples were tested using a commercial indirect ELISA for detection of MAP specific antibodies. The individual cow's results were dichotomised and used to estimate the within-herd antibody prevalence at each test-date. These prevalences were...... then combined with the ELISA reading on the BTM test-date closest to the cow-level test-date. A mixed-effect analysis of covariance with autoregressive type 1 correlation structure was carried out using the log-transformed BTM-ELISA results as outcome. This model was used to assess the correlation between...

  19. Evaluation of the clinical utility of a rapid blood test for human leptospirosis

    NARCIS (Netherlands)

    Eapen, C. K.; Sugathan, Sheela; Kuriakose, Mariamma; Abdoel, Theresia; Smits, Henk L.

    2002-01-01

    A rapid assay device for the detection of Leptospira-specific immunoglobulin M (IgM) antibodies was applied on whole blood samples collected from a group of consecutive patients admitted with clinical suspicion of leptospirosis to a district hospital in Kerala, India. The hospital is located in an

  20. Rapid prototyping of replica knee implants for in vitro testing

    Directory of Open Access Journals (Sweden)

    Verjans Mark

    2016-09-01

    Full Text Available The understanding of the complex biomechanics of the knee is a key for an optimal implant design. To easily investigate the influence of prosthetic designs on knee biomechanics a rapid prototyping workflow for knee implants has been developed and evaluated. Therefore, different manufacturing technologies and post-treatment methods have been examined and overall seven different replica knee implants were manufactured. For evaluation, the manufacturing properties such as surface accuracy and roughness were determined and kinematic behaviour was investigated in a novel knee testing rig. It was carried out that PolyJet-Modelling with a sanded surface resulted in changed kinematic patterns compared to a usual CoCr-UHMWPE implant. However, fused deposition modelling using ABS and subsequent surface smoothening with acetone vapor showed the lowest roughness of the manufactured implants and only minor kinematic differences. For this reason this method constitutes a promising approach towards an optimal implant design for improved patient-satisfaction and long lifetime of the implant. Finally the workflow is not only limited to the knee.

  1. Monitoring caries risks before the window of infection and later caries increment: a caries prediction study on rapid detection of Streptococcus mutans using monoclonal antibodies.

    Science.gov (United States)

    Maki, Yoshinobu; Sakayori, Takaharu; Hirata, SoIchiro; Ishii, Takuo; Tachino, Atsushi

    2014-01-01

    A new semi-quantitative enumeration system has been developed for the detection of Streptococcus mutans in saliva. Using two kinds of species-specific monoclonal antibodies, this system can quickly detect salivary S. mutans within 30 min and classify the results into three levels. The aim of this study was to evaluate the potential of this test kit in determining risk for the development of caries. Saliva samples collected during a compulsory dental examination from 56 children aged 18-months were tested. The children were classified into 3 groups according to the level of salivary S. mutans determined. After 18 months, 36 of the children underwent a second examination to investigate whether there was a correlation between salivary S. mutans level at the first examination and subsequent increment in caries. The results showed a good correlation between the two. This indicates that salivary S. mutans level before the window of infection is an indicator of caries risk and can be quickly detected using this test kit. This rapid test should be particularly useful in assessing risk of future caries in very young children.

  2. Highly Accurate Antibody Assays for Early and Rapid Detection of Tuberculosis in African and Asian Elephants

    Science.gov (United States)

    Tuberculosis (TB) in elephants is a re-emerging zoonotic disease caused primarily by Mycobacterium tuberculosis. Current methods for screening and diagnosis rely on trunk wash culture, which has serious limitations due to low test sensitivity, slow turn-around time, and variable sample quality. Inn...

  3. RAPID DETECTION OF RESPIRATORY VIRUSES USING MIXTURES OF MONOCLONAL-ANTIBODIES ON SHELL VIAL CULTURES

    NARCIS (Netherlands)

    SCHIRM, J; LUIJT, DS; PASTOOR, GW; MANDEMA, JM; SCHRODER, FP

    1992-01-01

    Eleven hundred and thirty-three clinical specimens submitted to the laboratory for diagnosis of respiratory virus infections were tested by direct immunofluorescence (DIF) for respiratory syncytial virus (RSV), by shell vial culture, and by conventional cell culture. The shell vial cultures were

  4. Inadequacy of IgM antibody tests for diagnosis of Rocky Mountain Spotted Fever.

    Science.gov (United States)

    McQuiston, Jennifer H; Wiedeman, Caleb; Singleton, Joseph; Carpenter, L Rand; McElroy, Kristina; Mosites, Emily; Chung, Ida; Kato, Cecilia; Morris, Kevin; Moncayo, Abelardo C; Porter, Susan; Dunn, John

    2014-10-01

    Among 13 suspected Rocky Mountain spotted fever (RMSF) cases identified through an enhanced surveillance program in Tennessee, antibodies to Rickettsia rickettsii were detected in 10 (77%) patients using a standard indirect immunofluorescent antibody (IFA) assay. Immunoglobulin M (IgM) antibodies were observed for 6 of 13 patients (46%) without a corresponding development of IgG, and for 3 of 10 patients (30%) at least 1 year post-onset. However, recent infection with a spotted fever group rickettsiae could not be confirmed for any patient, based on a lack of rising antibody titers in properly timed acute and convalescent serologic specimens, and negative findings by polymerase chain reaction testing. Case definitions used in national surveillance programs lack specificity and may capture cases that do not represent current rickettsial infections. Use of IgM antibodies should be reconsidered as a basis for diagnosis and public health reporting of RMSF and other spotted fever group rickettsiae in the United States. © The American Society of Tropical Medicine and Hygiene.

  5. Seroprevalence of Mycoplasma gallisepticum antibody by ELISA and serum plate agglutination test of laying chicken

    Directory of Open Access Journals (Sweden)

    Md. Zulfekar Ali

    2015-01-01

    Full Text Available Aim: Mycoplasma gallisepticum (MG is important avian pathogen responsible for chronic respiratory disease of chicken and turkeys, which result in large economic loss for the poultry industry. The objectives of this study were determination of seroprevalence of MG antibody of commercial layer chicken at laying period in selected areas of Bangladesh. Materials and Methods: A total of 563 blood samples were collected randomly from selected commercial layer chickens at laying period during the period from July to December, 2013. Indirect enzyme linked immunosorbent assay (iELISA and serum plate agglutination (SPA test were performed to detect the presence of antibodies against MG. Results: Of 563 samples, 64.47% and 56.13% showed an overall prevalence of MG antibodies in iELISA and SPA test respectively. Prevalence of MG was recorded the highest (69.63% at 50-55 weeks of age compared with lowest (53.26% at 56-61 weeks of age (p<0.05. Significant (p<0.05 effect of breed were observed in the seroprevalence of MG infection in layer birds in the present study. The overall, 68.77%, 63.74% and 59.37% prevalence were found respectively in sonali, ISA Brown and White leg horn. The prevalence of MG antibodies was the highest (70.13% in December followed by November (68%, October (65.67%, August (63.46%, September (58.54% and July (51.78% month. The seroprevalence of MG antibodies was higher (69.63% in most of the large flocks and lower (56.82% in small flocks. Conclusion: Therefore, might be suggested that the commercial layer farms should be routinely checked to monitor MG infection and the reactor birds should be culled since MG organism has the potential to transmit vertically. The correlation between MG antibody in month and flock size was not significant (p=0.359 and p=0.868, respectively.

  6. Epitrochoid Power-Law Nozzle Rapid Prototype Build/Test Project (Briefing Charts)

    Science.gov (United States)

    2015-02-01

    Power-Law Nozzle Rapid Prototype Build/Test Project Mr. Eric J. Paulson-Vehicle Analyst Rocket Propulsion Division Combustion devices Branch Systems...to build axisymmetric cold flow nozzle test articles using plastic-based inexpensive rapid additive manufacturing – Feasible to rapid prototype lobed...Briefing Charts 3. DATES COVERED (From - To) February 2015-March 2015 4. TITLE AND SUBTITLE Epitrochoid Power-Law Nozzle Rapid Prototype Build/Test

  7. Rabies direct fluorescent antibody test does not inactivate rabies or eastern equine encephalitis viruses.

    Science.gov (United States)

    Jarvis, Jodie A; Franke, Mary A; Davis, April D

    2016-08-01

    An examination using the routine rabies direct fluorescent antibody test was performed on rabies or Eastern equine encephalitis positive mammalian brain tissue to assess inactivation of the virus. Neither virus was inactivated with acetone fixation nor the routine test, thus laboratory employees should treat all samples as rabies and when appropriate Eastern equine encephalitis positive throughout the whole procedure. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. A Novel, Rapid Assay for Detection and Differentiation of Serotype-Specific Antibodies to Venezuelan Equine Encephalitis Complex Alphaviruses

    National Research Council Canada - National Science Library

    Wang, Eryu; Paessler, Slobodan; Smith, Darci R; Coffey, Lark L; Kang, Wenli; Estrada-Franco, Jose; Weaver, Scott C; Aguilar, Patricia V; Pfeffer, Martin; Olson, James

    2005-01-01

    ... of Venezuelan equine encephalitis (VEE) virus. Two monoclonal antibodies that differentially recognize epizootic versus enzootic VEE virus epitopes were used to measure the serotype-specific blocking abilities of antibodies in sera of naturally...

  9. RAPID TEST METHOD FOR EVALUATION OF ANTIFREEZE ADDITIVE EFFICIENCY

    Directory of Open Access Journals (Sweden)

    S. V. Gushchin

    2015-01-01

    Full Text Available Usage of chemical additives while executing concrete works at negative temperatures is considered as a convenient and economical method. Range of the used antifreeze additives is rather wide. A great number of new additives are advertised but their characteristics have not been practically studied. Evaluation of the antifreeze additive efficiency is unfortunately rather long process and it does not provide comprehensive data on concrete structure formation processes. Due to this development of rapid and comprehensive methodology for construction companies is urgently required.Freezing processes of antifreeze additive aqueous solutions and hardening of cement paste with them have been investigated in the paper. The paper proposes a methodology for determination of freezing point for aqueous solutions of chemical additives of various applications. Identity of  freezing point for a chemical additive aqueous solution and cement paste with an equal concentration of the additive in the paste pore fluid has been determined while taking  calcium nitrate and sodium formate additives as an example. The paper demonstrates the possibility to evaluate efficiency of antifreeze additive action on the basis of kinetics in temperature changes of the cement paste with additives by its consecutive freezing and defrosting.  A methodology for operational evaluation in the field of chemical additive application for concreting items at negative temperatures has been offered in the paper.  The methodology does not require  deficient and expensive test-equipment. It can be applied at ordinary construction companies and it is comprehensible for personnel of low-qualification.  The paper shows the possibility to develop an original methodology for designing concrete structure which is based on operating efficiency determinations  for single and integrated antifreeze additives.

  10. Ninhydrin sweat test: a simple method for detecting antibodies neutralizing botulinum toxin type A.

    Science.gov (United States)

    Voller, Bernhard; Moraru, Ekaterina; Auff, Eduard; Benesch, Michael; Poewe, Werner; Wissel, Jörg; Müller, Jörg; Entner, Tanja; Bigalke, Hans; Schnider, Peter

    2004-08-01

    Approximately 5% of patients with cervical dystonia receiving repeated botulinum neurotoxin A (BoNT/A) injections develop secondary loss of treatment benefit. Currently available tests to directly detect neutralizing BoNT/A antibodies (BoNT/A-AB) are either expensive or time consuming. To establish a simple, clinically useful test for antibody detection, we adapted the ninhydrin sweat test (NST). Eighteen dystonic patients with secondary nonresponse and clinically suspected BoNT/A-AB formation were tested for BoNT/A-AB in the mouse diaphragm test (MDT). In addition, the size of the anhidrotic area was determined by the NST 21 days after an intradermal dose of 10 U Dysport into the hypothenar region of the left palm. In nine patients, positive BoNT-AB titers were found in the MDT. There was a significant correlation between the BoNT/A-AB titers and the anhidrotic area (Spearman's rho = -0.9, P < 0.0001). Both tests provided comparably good results with respect to qualitative antibody detection. In the clinical situation of secondary nonresponse to BoNT/A therapy, the economical NST may be a helpful tool to detect neutralizing BoNT/A-AB. Copyright 2004 Movement Disorder Society

  11. Prospective evaluation of three rapid diagnostic tests for diagnosis of human leptospirosis.

    Directory of Open Access Journals (Sweden)

    Marga G A Goris

    Full Text Available BACKGROUND: Diagnosis of leptospirosis by the microscopic agglutination test (MAT or by culture is confined to specialized laboratories. Although ELISA techniques are more common, they still require laboratory facilities. Rapid Diagnostic Tests (RDTs can be used for easy point-of-care diagnosis. This study aims to evaluate the diagnostic performance of the RDTs LeptoTek Dri Dot, LeptoTek Lateral Flow, and Leptocheck-WB, prospectively. METHODOLOGY: During 2001 to 2012, one or two of the RDTs at the same time have been applied prior to routine diagnostics (MAT, ELISA and culture on serum specimens from participants sent in for leptospirosis diagnosis. The case definition was based on MAT, ELISA and culture results. Participants not fulfilling the case definition were considered not to have leptospirosis. The diagnostic accuracy was determined based on the 1(st submitted sample and paired samples, either in an overall analysis or stratified according to days post onset of illness. RESULTS: The overall sensitivity and specificity for the LeptoTek Dri Dot was 75% respectively 96%, for the LeptoTek Lateral Flow 78% respectively 95%, and for the Leptocheck-WB 78% respectively 98%. Based on the 1(st submitted sample the sensitivity was low (51% for LeptoTek Dri Dot, 69% for LeptoTek Lateral Flow, and 55% for Leptocheck-WB, but substantially increased when the results of paired samples were combined, although accompanied by a lower specificity (82% respectively 91% for LeptoTek Dri Dot, 86% respectively 84% for LeptoTek Lateral Flow, and 80% respectively 93% for Leptocheck-WB. CONCLUSIONS: All three tests present antibody tests contributing to the diagnosis of leptospirosis, thus supporting clinical suspicion and contributing to awareness. Since the overall sensitivity of the tested RDTs did not exceed 80%, one should be cautious to rely only on an RDT result, and confirmation by reference tests is strongly recommended.

  12. A Laboratory-Based Evaluation of Four Rapid Point-of-Care Tests for Syphilis

    Science.gov (United States)

    Causer, Louise M.; Kaldor, John M.; Fairley, Christopher K.; Donovan, Basil; Karapanagiotidis, Theo; Leslie, David E.; Robertson, Peter W.; McNulty, Anna M.; Anderson, David; Wand, Handan; Conway, Damian P.; Denham, Ian; Ryan, Claire; Guy, Rebecca J.

    2014-01-01

    Background Syphilis point-of-care tests may reduce morbidity and ongoing transmission by increasing the proportion of people rapidly treated. Syphilis stage and co-infection with HIV may influence test performance. We evaluated four commercially available syphilis point-of-care devices in a head-to-head comparison using sera from laboratories in Australia. Methods Point-of-care tests were evaluated using sera stored at Sydney and Melbourne laboratories. Sensitivity and specificity were calculated by standard methods, comparing point-of-care results to treponemal immunoassay (IA) reference test results. Additional analyses by clinical syphilis stage, HIV status, and non-treponemal antibody titre were performed. Non-overlapping 95% confidence intervals (CI) were considered statistically significant differences in estimates. Results In total 1203 specimens were tested (736 IA-reactive, 467 IA-nonreactive). Point-of-care test sensitivities were: Determine 97.3%(95%CI:95.8–98.3), Onsite 92.5%(90.3–94.3), DPP 89.8%(87.3–91.9) and Bioline 87.8%(85.1–90.0). Specificities were: Determine 96.4%(94.1–97.8), Onsite 92.5%(90.3–94.3), DPP 98.3%(96.5–99.2), and Bioline 98.5%(96.8–99.3). Sensitivity of the Determine test was 100% for primary and 100% for secondary syphilis. The three other tests had reduced sensitivity among primary (80.4–90.2%) compared to secondary syphilis (94.3–98.6%). No significant differences in sensitivity were observed by HIV status. Test sensitivities were significantly higher among high-RPR titre (RPR≥8) (range: 94.6–99.5%) than RPR non-reactive infections (range: 76.3–92.9%). Conclusions The Determine test had the highest sensitivity overall. All tests were most sensitive among high-RPR titre infections. Point-of-care tests have a role in syphilis control programs however in developed countries with established laboratory infrastructures, the lower sensitivities of some tests observed in primary syphilis suggest these would

  13. A laboratory-based evaluation of four rapid point-of-care tests for syphilis.

    Directory of Open Access Journals (Sweden)

    Louise M Causer

    Full Text Available BACKGROUND: Syphilis point-of-care tests may reduce morbidity and ongoing transmission by increasing the proportion of people rapidly treated. Syphilis stage and co-infection with HIV may influence test performance. We evaluated four commercially available syphilis point-of-care devices in a head-to-head comparison using sera from laboratories in Australia. METHODS: Point-of-care tests were evaluated using sera stored at Sydney and Melbourne laboratories. Sensitivity and specificity were calculated by standard methods, comparing point-of-care results to treponemal immunoassay (IA reference test results. Additional analyses by clinical syphilis stage, HIV status, and non-treponemal antibody titre were performed. Non-overlapping 95% confidence intervals (CI were considered statistically significant differences in estimates. RESULTS: In total 1203 specimens were tested (736 IA-reactive, 467 IA-nonreactive. Point-of-care test sensitivities were: Determine 97.3%(95%CI:95.8-98.3, Onsite 92.5%(90.3-94.3, DPP 89.8%(87.3-91.9 and Bioline 87.8%(85.1-90.0. Specificities were: Determine 96.4%(94.1-97.8, Onsite 92.5%(90.3-94.3, DPP 98.3%(96.5-99.2, and Bioline 98.5%(96.8-99.3. Sensitivity of the Determine test was 100% for primary and 100% for secondary syphilis. The three other tests had reduced sensitivity among primary (80.4-90.2% compared to secondary syphilis (94.3-98.6%. No significant differences in sensitivity were observed by HIV status. Test sensitivities were significantly higher among high-RPR titre (RPR ≥ 8 (range: 94.6-99.5% than RPR non-reactive infections (range: 76.3-92.9%. CONCLUSIONS: The Determine test had the highest sensitivity overall. All tests were most sensitive among high-RPR titre infections. Point-of-care tests have a role in syphilis control programs however in developed countries with established laboratory infrastructures, the lower sensitivities of some tests observed in primary syphilis suggest these would need to be

  14. The diagnostic accuracy of three rapid diagnostic tests for typhoid fever at Chittagong Medical College Hospital, Chittagong, Bangladesh.

    Science.gov (United States)

    Maude, Rapeephan R; de Jong, Hanna K; Wijedoru, Lalith; Fukushima, Masako; Ghose, Aniruddha; Samad, Rasheda; Hossain, Mohammed Amir; Karim, Mohammed Rezaul; Faiz, Mohammed Abul; Parry, Christopher M

    2015-10-01

    To determine the diagnostic accuracy of three rapid diagnostic tests (RDTs) for typhoid fever in febrile hospitalised patients in Bangladesh. Febrile adults and children admitted to Chittagong Medical College Hospital, Bangladesh, were investigated with Bact/Alert(®) blood cultures and real-time PCR to detect Salmonella enterica Typhi and Paratyphi A and assays for Rickettsia, leptospirosis and dengue fever. Acute serum samples were examined with the LifeAssay (LA) Test-it™ Typhoid IgM lateral flow assay detecting IgM antibodies against S. Typhi O antigen, CTKBiotech Onsite Typhoid IgG/IgM Combo Rapid-test cassette lateral flow assay detecting IgG and IgM antibodies against S. Typhi O and H antigens and SD Bioline line assay for IgG and IgM antibodies against S. Typhi proteins. In 300 malaria smear-negative febrile patients [median (IQR) age of 13.5 (5-31) years], 34 (11.3%) had confirmed typhoid fever: 19 positive by blood culture for S. Typhi (three blood PCR positive) and 15 blood culture negative but PCR positive for S. Typhi in blood. The respective sensitivity and specificity of the three RDTs in patients using a composite reference standard of blood culture and/or PCR-confirmed typhoid fever were 59% and 61% for LifeAssay, 59% and 74% for the CTK IgM and/or IgG, and 24% and 96% for the SD Bioline RDT IgM and/or IgG. The LifeAssay RDT had a sensitivity of 63% and a specificity of 91% when modified with a positive cut-off of ≥2+ and analysed using a Bayesian latent class model. These typhoid RDTs demonstrated moderate diagnostic accuracies, and better tests are needed. © 2015 The Authors. Tropical Medicine & International Health Published by John Wiley & Sons Ltd.

  15. Autoantibodies to beta2-glycoprotein I in systemic lupus erythematosus and primary antiphospholipid antibody syndrome: clinical correlations in comparison with other antiphospholipid antibody tests.

    Science.gov (United States)

    Day, H M; Thiagarajan, P; Ahn, C; Reveille, J D; Tinker, K F; Arnett, F C

    1998-04-01

    To examine relationships between anti-beta2-glycoprotein (beta2-GPI) antibodies and other antiphospholipid antibody (aPL) tests (aPL ELISA and the lupus anticoagulant or LAC) and the associations of each of these aPL tests with individual clinical manifestations of the antiphospholipid antibody syndrome (APS). IgG and IgM anti-beta2-GPI antibodies were determined by ELISA in 281 patients with SLE, primary APS, or other connective tissue diseases. Frequencies, sensitivities, specificities, and predictive values and correlations of anti-beta2-GPI were compared to the aPL ELISA (IgG and IgM) and LAC for individual (and combined) features of APS. Among 139 patients with positive aPL ELISA and/or LAC tests, 57 (41%) had anti-beta2-GPI antibodies (IgG and/or IgM) compared to 11% of patients with SLE negative for these tests (p = 0.00001). In 130 patients with APS, anti-beta2-GPI occurred in 42% and tended to be more specific but less sensitive than the aPL ELISA or LAC. When all 3 aPL tests were combined, the best sensitivities and negative predictive values were achieved; however, specificity and positive predictive values remained low. Anti-beta2-GPI antibodies occurred more frequently in primary APS (58%) vs secondary antiphospholipid syndromes (33%) (p = 0.008, OR = 2.9). Among 79 patients with SLE negative by both aPL ELISA and LAC, 9 (11 %) were positive for anti-beta2-GPI, 7 of whom had clinical features consistent with APS (representing 5% of all with APS). Stepwise multiple logistic regression analysis revealed beta2-GPI to be most strongly associated with neurological syndromes other than stroke, deep venous thrombosis, and recurrent fetal loss, while LAC was most strongly correlated with stroke and thrombocytopenia. IgM aPL antibodies also were independently associated with neurological syndromes and recurrent fetal loss. Testing for beta2-GPI antibodies may be clinically useful in the diagnosis of APS but cannot supplant other aPL ELISA or LAC. Multivariate

  16. Performance of a rapid, on-site human immunodeficiency virus antibody assay in a public health setting.

    Science.gov (United States)

    Kassler, W J; Haley, C; Jones, W K; Gerber, A R; Kennedy, E J; George, J R

    1995-11-01

    Rapid, on-site human immunodeficiency virus (HIV) testing has the potential to improve the delivery of prevention services in publicly funded counseling and testing sites. The Single Use Diagnostic System (SUDS) HIV-1 is the only rapid enzyme immunoassay (EIA) approved for diagnostic use in the United States. To evaluate the feasibility of using SUDS in public clinics and to validate the test's performance in a public health laboratory, we conducted blinded SUDS testing on plasma sent for HIV testing. From 19 March through 30 June 1993, 1,923 consecutive samples from a sexually transmitted diseases clinic and an HIV counseling and testing clinic were tested on site with SUDS. Tests done in the first two weeks with a malfunctioning centrifuge n = 402) and those done when there were excessively high temperatures in the laboratory (n = 53) were analyzed separately. Of 1,466 tests, 39 were positive by both SUDS and EIA (with Western blot [immunoblot] confirmation) and 7 were SUDS positive and EIA negative. Western blotting was used as the "gold standard" to adjudicate these discrepancies. There were no SUDS-negative and EIA-positive tests. Compared with that of EIA (with Western blot confirmation), the sensitivity of SUDS was 100% (95% confidence interval, 88.8 to 100%) and the specificity was 99.5% (95% confidence interval, 98.9 to 99.8%). The positive predictive value of SUDS was 88% in the STD clinic and 81% in the HIV counseling and testing clinic. There was a 7.7-fold increase in false positives, from 0.48 to 3.7%, when there was inadequate centrifugation and when the temperature exceeded the manufacturer's recommendations. Rapid, on-site HIV testing by the SUDS assay is feasible and practical in public health settings. The test can be performed accurately, at reasonable cost, and within the time frame of a typical clinic visit. Caution should be used, however, as two conditions adversely affected the accuracy of this test: inadequate specimen preparation and

  17. Comparison of Platforms for Testing Antibody Responses against the Chlamydia trachomatis Antigen Pgp3.

    Science.gov (United States)

    Gwyn, Sarah; Cooley, Gretchen; Goodhew, Brook; Kohlhoff, Stephan; Banniettis, Natalie; Wiegand, Ryan; Martin, Diana L

    2017-12-01

    Antibody responses to Chlamydia trachomatis (CT) antigens may be useful tools for surveillance of trachoma by estimating cumulative prevalence of infection within a population. Data were compared from three different platforms-multiplex bead array (MBA), enzyme-linked immunosorbent assay (ELISA), and lateral flow assay (LFA)-measuring antibody responses against the CT antigen protein plasmid gene product 3 (Pgp3). Sensitivity was defined as the proportion of specimens testing antibody positive from a set of dried blood spots from Tanzanian 1-9-year olds who were positive for CT nucleic acid of all nucleic acid amplification test (NAAT)-positive individuals (N = 103). The sensitivity of the LFA could not be determined because of the use of dried blood spots for this test; this specimen type has yet to be adapted to LFA. Specificity was defined as the proportion of sera from U.S. and Bolivian 1-9-year olds that had previously tested negative by the Chlamydia microimmunofluorescence (MIF) assay testing negative to Pgp3-specific antibodies (N = 154). The sensitivity for MBA and ELISA was the same-93.2 (95% confidence interval [CI]: 88.3-98.1). Specificity ranged across platforms from 96.1 (95% CI: 91.8-98.2) to 99.4% (95% CI: 98.2-100). ELISA performance was similar regardless of whether the plates were precoated or freshly coated with antigen. Sensitivity and specificity of control panels were similar if the cutoff was determined using receiver operator curves or a finite mixture model, but the cutoffs themselves differed by approximately 0.5 OD using the different methodologies. These platforms show good sensitivity and specificity and show good agreement between tests at a population level, but indicate variability for ELISA outcomes depending on the cutoff determination methodology.

  18. Thyroid Antibodies

    Science.gov (United States)

    ... Fungal Infections Gout Graves Disease Guillain-Barré Syndrome Hashimoto Thyroiditis Heart Attack and Acute Coronary Syndrome Heart ... hypothyroidism or hyperthyroidism , such as Graves disease or Hashimoto thyroiditis . Thyroid antibody tests include: Thyroid peroxidase antibody ( ...

  19. Buffer substitution in malaria rapid diagnostic tests causes false-positive results

    Directory of Open Access Journals (Sweden)

    Van den Ende Jef

    2010-07-01

    Full Text Available Abstract Background Malaria rapid diagnostic tests (RDTs are kits that generally include 20 to 25 test strips or cassettes, but only a single buffer vial. In field settings, laboratory staff occasionally uses saline, distilled water (liquids for parenteral drugs dilution or tap water as substitutes for the RDT kit's buffer to compensate for the loss of a diluent bottle. The present study assessed the effect of buffer substitution on the RDT results. Methods Twenty-seven RDT brands were run with EDTA-blood samples of five malaria-free subjects, who were negative for rheumatoid factor and antinuclear antibodies. Saline, distilled water and tap water were used as substitute liquids. RDTs were also run with distilled water, without adding blood. Results were compared to those obtained with the RDT kit's buffer and Plasmodium positive samples. Results Only eight cassettes (in four RDT brands showed no control line and were considered invalid. Visible test lines occurred for at least one malaria-free sample and one of the substitutes in 20/27 (74% RDT brands (saline: n = 16; distilled water: n = 17; and tap water: n = 20, and in 15 RDTs which were run with distilled water only. They occurred for all Plasmodium antigens and RDT formats (two-, three- and four-band RDTs. Clearance of the background of the strip was excellent except for saline. The aspects (colour, intensity and crispness of the control and the false-positive test lines were similar to those obtained with the RDT kits' buffer and Plasmodium positive samples. Conclusion Replacement of the RDT kit's dedicated buffer by saline, distilled water and tap water can cause false-positive test results.

  20. An automated screening test for antibodies to human immunodeficiency virus-1.

    Science.gov (United States)

    Sekiguchi, S; Ikeda, H; Kato, T; Maeda, R; Fukai, K

    1988-01-01

    An automated pretransfusion testing system was applied to HIV antibody screening by a gelatin particle agglutination (HIV-PA) test. The test conditions for the test, such as diluent, plate shape, and incubation time, were applicable not only for the HIV-PA test but also for other routine tests, including those for hepatitis B surface antigen and HTLV-1 antibodies. After a 60-minute incubation, the plates were read automatically and then were assessed visually. Tests with seropositive samples obtained from hemophiliacs and an HIV enzyme immunoassay (EIA) familiarization panel showed that the automated HIV-PA test was more sensitive than the EIA and did not show a false-negative result. Of 11,300 blood donors, 44 were positive by the automated test, and 51 were positive by the EIA. None of the blood donors was confirmed to be seropositive. Using the automated test, a large number of samples could be screened in a relatively short time without a significant increase of nonspecific reactions.

  1. Antithyroglobulin antibody

    Science.gov (United States)

    Thyroglobulin antibody; Thyroiditis - thyroglobulin antibody; Hypothyroidism - thyroglobulin antibody; Thyroiditis - thyroglobulin antibody; Graves disease - thyroglobulin antibody; Underactive thyroid - thyroglobulin antibody

  2. Development of a simultaneous lateral flow strip test for the rapid and simple detection of deoxynivalenol and zearalenone.

    Science.gov (United States)

    Kim, Kyeong-Yeol; Shim, Won-Bo; Kim, Jeong-Sook; Chung, Duck-Hwa

    2014-10-01

    The objective of this study was to develop a 1-step simultaneous lateral flow strip test for the rapid and simple detection of deoxynivalenol (DON) and zearalenone (ZEA) in grains. Two monoclonal antibodies (MAbs) against DON and ZEA were respectively conjugated with gold nanoparticles and used to develop a lateral flow strip test for a single toxin and multiple toxins. First, individual lateral flow strips for a single toxin were optimized, and their conditions were used to develop a simultaneous lateral flow strip for multiple toxins. Limits of detection of both lateral flow strip tests for DON and ZEA were the same (DON: 50 ng/mL, ZEA: 1 ng/mL). Both methods showed cross-reactivity for α-zearalenol and β-zearalenol, but no cross-reaction to other mycotoxins. The results can be completed obtained within 15 min. The cut-off values of the simultaneous lateral flow strip for the spiked rice and corn were 500 and 10 ng/g for DON and ZEA, respectively. The results demonstrated that the developed simultaneous lateral flow strip test offers a rapid, easy-to-use, and portable analytical system and can be used as a convenient qualitative tool for the on-site detection of DON and ZEA in food and agricultural commodities. Simultaneous lateral strip test is useful for a rapid detection of DON and ZEA at a time in food and grain samples. © 2014 Institute of Food Technologists®

  3. Field-friendly serological tests for determination of M. leprae-specific antibodies

    National Research Council Canada - National Science Library

    Anouk van Hooij; Elisa M Tjon Kon Fat; Susan J F van den Eeden; Louis Wilson; Moises Batista da Silva; Claudio G Salgado; John S Spencer; Paul L A M Corstjens; Annemieke Geluk

    2017-01-01

    .... leprae PGL-I represent a useful biomarker for detecting multibacillary (MB) patients. Since efficient leprosy diagnosis requires field-friendly test conditions, we evaluated two rapid lateral flow assays (LFA...

  4. Intestinal biopsy is not always required to diagnose celiac disease: a retrospective analysis of combined antibody tests

    Directory of Open Access Journals (Sweden)

    Bürgin-Wolff Annemarie

    2013-01-01

    Full Text Available Abstract Background The objective of this study was to compare celiac disease (CD– specific antibody tests to determine if they could replace jejunal biopsy in patients with a high pretest probability of CD. Methods This retrospective study included sera from 149 CD patients and 119 controls, all with intestinal biopsy. All samples were analyzed for IgA and IgG antibodies against native gliadin (ngli and deamidated gliadin peptides (dpgli, as well as for IgA antibodies against tissue transglutaminase and endomysium. Results Tests for dpgli were superior to ngli for IgG antibody determination: 68% vs. 92% specificity and 79% vs. 85% sensitivity for ngli and dpgli, respectively. Positive (76% vs. 93% and negative (72% vs. 83% predictive values were also higher for dpgli than for ngli. Regarding IgA gliadin antibody determination, sensitivity improved from 61% to 78% with dpgli, while specificity and positive predictive value remained at 97% (P Conclusion Antibody tests for dpgli yielded superior results compared with ngli. A combination of three or four antibody tests including IgA anti-tissue transglutaminase and/or IgA anti- endomysium permitted diagnosis or exclusion of CD without intestinal biopsy in a high proportion of patients (78%. Jejunal biopsy would be necessary in patients with discordant antibody results (22%. With this two-step procedure, only patients with no CD-specific antibodies would be missed.

  5. Interference of daratumumab with pretransfusion testing, mimicking a high-titer, low avidity like antibody

    Directory of Open Access Journals (Sweden)

    Mei-Hwa Lin

    2017-01-01

    Full Text Available Daratumumab is a monoclonal immunoglobulin against CD38 and has been approved for treating patients with refractory multiple myeloma. The presence of daratumumab in the sera can interfere with pretransfusion testing due to the weakly expression of CD38 on red cells. The reactivity could be mistaken as autoantibody (if autocontrol is positive or alloantibody (if autocontrol is negative. We present a case that demonstrates daratumumab could mimic a high titer low avidity (HTLA alloantibody. A 34-year-old male patient of refractory myeloma was recruited in phase three clinical trial involving daratumumab. Samples were sent to the blood bank for pretransfusion testing. Without knowledge of patient having used daratumumab, we mistook the reactivity in the patient's sera as an HTLA antibody due to the results of negative autocontrol and high titers of antibody activity. Antibody screen showed a panreactive pattern and the reactivity against screening cells was up to a titer of 1: 1240. The reactivity was weaker against cord cells than adult cells, became weaker against ZZAP-treated cells and became negative against DDT-treated cells. A discussion with attending physician finally revealed the reactivity was due to the interference caused by daratumumab. The case demonstrates good communication is essential in performing pretransfusion testing for patients receiving daratumumab and other new biological regimens that can interfere with compatibility test.

  6. Interference of daratumumab with pretransfusion testing, mimicking a high-titer, low avidity like antibody.

    Science.gov (United States)

    Lin, Mei-Hwa; Liu, Fei-Yun; Wang, Hsiu-Mien; Cho, Hsin-Ching; Lo, Shyh-Chyi

    2017-01-01

    Daratumumab is a monoclonal immunoglobulin against CD38 and has been approved for treating patients with refractory multiple myeloma. The presence of daratumumab in the sera can interfere with pretransfusion testing due to the weakly expression of CD38 on red cells. The reactivity could be mistaken as autoantibody (if autocontrol is positive) or alloantibody (if autocontrol is negative). We present a case that demonstrates daratumumab could mimic a high titer low avidity (HTLA) alloantibody. A 34-year-old male patient of refractory myeloma was recruited in phase three clinical trial involving daratumumab. Samples were sent to the blood bank for pretransfusion testing. Without knowledge of patient having used daratumumab, we mistook the reactivity in the patient's sera as an HTLA antibody due to the results of negative autocontrol and high titers of antibody activity. Antibody screen showed a panreactive pattern and the reactivity against screening cells was up to a titer of 1: 1240. The reactivity was weaker against cord cells than adult cells, became weaker against ZZAP-treated cells and became negative against DDT-treated cells. A discussion with attending physician finally revealed the reactivity was due to the interference caused by daratumumab. The case demonstrates good communication is essential in performing pretransfusion testing for patients receiving daratumumab and other new biological regimens that can interfere with compatibility test.

  7. Field evaluation of the performance and testing costs of a rapid point-of-care test for syphilis in a red-light district of Manaus, Brazil.

    Science.gov (United States)

    Benzaken, A S; Sabidó, M; Galban, E G; Pedroza, V; Vasquez, F; Araújo, A; Peeling, R W; Mayaud, P

    2008-08-01

    To assess the performance, usefulness and cost of a rapid treponemal antibody assay (VisiTect Syphilis) to detect syphilis in high risk populations. People who attended STI clinics in Manaus, Brazil, were screened for syphilis using the fluorescent treponemal antibody absorption (FTA-Abs) test and a non-treponemal test (Venereal Diseases Research Laboratory (VDRL)), and for HIV. Finger prick blood samples were tested with VisiTect Syphilis. The rapid test was evaluated against the reference FTA-Abs and for its usefulness in detecting active syphilis (FTA-Abs and VDRL positive). Operational performance was assessed through providers' and patients' interviews. An economic evaluation was conducted from the provider's perspective. 510 patients (60% men) were enrolled, of whom 13 (2.5%) were HIV-1 seropositive. Syphilis prevalence (FTA-Abs) was 18% and active syphilis prevalence was 7.5%. 11% (57/506) of samples were positive by VisiTect. The sensitivity, specificity, positive and negative predictive values of VisiTect Syphilis were 57% (95% CI 45.8 to 66.7), 99% (95% CI 97.0 to 99.6), 91% (95% CI 80.0 to 96.7) and 91% (95% CI 88.0 to 93.5), respectively. VisiTect Syphilis identified 79% (30/38) of active syphilis cases. The cost per case of syphilis was $16.8 for VDRL, $33.2 for low cost and $56.3 for high cost VisiTect Syphilis; the cost per case of active syphilis was $21.3, $57.5 and $97.6, respectively. Patients identified finger prick pain and preference for venous blood collection as minor barriers to test use. VisiTect Syphilis had low sensitivity in field use and was less cost effective than conventional VDRL. However, rapid and correct identification of a high proportion of active syphilis cases combined with operational characteristics suggest a role in high risk populations.

  8. Evaluation of a bovine antibody test for diagnosing Mycobacterium avium complex in patients with cystic fibrosis

    DEFF Research Database (Denmark)

    Qvist, Tavs; Pressler, Tacjana; Katzenstein, Terese L.

    2017-01-01

    Introduction: The aim of this study was to test a commercial bovine enzyme-linked immunosorbent assay for investigating antibody activity against Mycobacterium avium complex. Methods: All patients at the Copenhagen Cystic Fibrosis (CF) Center who had culture for nontuberculous mycobacteria...... before and after culture conversion was performed in case patients. Results: Out of 286 included subjects, six had clinical M. avium complex pulmonary disease at the time of sera sampling. These patients presented with higher antibody test values (P-value ... at ruling out pulmonary disease. Screening sera from patients with CF could guide clinicians to focus attention on patients at higher risk of M. avium complex pulmonary disease. Pediatr Pulmonol. 2017;52:34–40....

  9. Comparison of Rapid Diagnostic Tests and Microscopy for Malaria ...

    African Journals Online (AJOL)

    Presumptive treatment of malaria results in significant overuse of antimalarials. This study compared the diagnostic accuracy of Histidine Rich Protein II and plasmodium lactate dehydrogenase (pLDH)-based Rapid Kits( RDTs)and using expert microscopy as the gold standard for the detection of falciparum and ...

  10. Comparative study of blood smears microscopy and rapid test strips ...

    African Journals Online (AJOL)

    To evaluate two of the currently available assay methods, specimen from 200 patients admitted on provisional diagnosis of malaria were screened in this study and compared with the smear microscopy method. Our results showed a statistical significant difference (p< 0.05) between the two rapid strip methods of ACON and ...

  11. Evaluation of nine HIV rapid test kits to develop a national HIV testing algorithm in Nigeria

    Directory of Open Access Journals (Sweden)

    Orji Bassey

    2015-05-01

    Full Text Available Background: Non-cold chain-dependent HIV rapid testing has been adopted in many resource-constrained nations as a strategy for reaching out to populations. HIV rapid test kits (RTKs have the advantage of ease of use, low operational cost and short turnaround times. Before 2005, different RTKs had been used in Nigeria without formal evaluation. Between 2005 and 2007, a study was conducted to formally evaluate a number of RTKs and construct HIV testing algorithms. Objectives: The objectives of this study were to assess and select HIV RTKs and develop national testing algorithms. Method: Nine RTKs were evaluated using 528 well-characterised plasma samples. These comprised 198 HIV-positive specimens (37.5% and 330 HIV-negative specimens (62.5%, collected nationally. Sensitivity and specificity were calculated with 95% confidence intervals for all nine RTKs singly and for serial and parallel combinations of six RTKs; and relative costs were estimated. Results: Six of the nine RTKs met the selection criteria, including minimum sensitivity and specificity (both ≥ 99.0% requirements. There were no significant differences in sensitivities or specificities of RTKs in the serial and parallel algorithms, but the cost of RTKs in parallel algorithms was twice that in serial algorithms. Consequently, three serial algorithms, comprising four test kits (BundiTM, DetermineTM, Stat-Pak® and Uni-GoldTM with 100.0% sensitivity and 99.1% – 100.0% specificity, were recommended and adopted as national interim testing algorithms in 2007. Conclusion: This evaluation provides the first evidence for reliable combinations of RTKs for HIV testing in Nigeria. However, these RTKs need further evaluation in the field (Phase II to re-validate their performance.

  12. Helicobacter pylori Test

    Science.gov (United States)

    ... Content Related Images View Sources Also Known As H. pylori antibody test, stool antigen, breath tests Urea breath test CLO test Rapid urease test (RUT) for H. pylori Formal Name Helicobacter pylori This article was last ...

  13. A Simple Saliva-Based Test for Detecting Antibodies to Human Immunodeficiency Virus*

    OpenAIRE

    Schramm, Willfried; Angulo, Gustavo Barriga; Torres, Patricia Castillo; Burgess-Cassler, Anthony

    1999-01-01

    This study was performed to determine the feasibility of using saliva as a diagnostic medium for the detection of antibodies to human immunodeficiency virus type 1 (HIV-1) and HIV-2 under nonlaboratory conditions and to evaluate the performance characteristics of such a test. We developed for this purpose a self-contained kit (Saliva · Strip [ST]), which combines the collection and processing, as well as the analysis, of the specimen. The kit’s performance was eval...

  14. Interlaboratory testing of porcine sera for antibodies to porcine circovirus type 2

    DEFF Research Database (Denmark)

    McNair, I.; Marshall, M.; McNeilly, F.

    2004-01-01

    A panel of 20 porcine sera was distributed to 5 laboratories across Europe and Canada. Each center was requested to test the sera for the presence of porcine circovirus type 2 antibodies using the routine assays, indirect immunofluorescence assay (IFA) and indirect immunoperoxidase monolayer assa...... than did IFA, and paraformaldehyde gave higher titers than did acetone or ethyl alcohol. This report highlights the need for standardized procedures and biologicals for this virus....

  15. [Evaluation of a rapid diagnostic test in the diagnosis of toxoplasmosis in pregnant women in Cotonou (Bénin)].

    Science.gov (United States)

    Ogouyèmi-Hounto, A; Agbayahoun-Chokki, F; Sissinto Savi de Tove, Y; Biokou Bankole, B; Adinsi de Souza, V; Assogba, M; Kinde-Gazard, D; Massougbodji, A

    2014-05-01

    The aim of the study was to evaluate the performance of the ImmunoComb® Toxo IgG and ImmunoComb® Toxo IgMassays (rapid diagnostic test) in the laboratory diagnosis of toxoplasmosis in pregnant women in Cotonou. We interviewed 266 pregnant women, who first answered an epidemiological questionnaire, and collected blood samples for measurement of IgG and IgM anti T. gondii antibodies with the ImmunoComb toxo assays and with the ARCHITECT CIMA method. The sensitivity, specificity, positive predictive values (PPV) and negative predictive values (NPV) were calculated to determine the performance of the rapid test. The seroprevalences of IgG against T. gondii by CIMA technique and rapid test were respectively 48.9% and 48.5%. The prevalence increased with age. Performances for IgG were: sensitivity 97%, specificity 100%, PPV 100%, NPV = 97.10%. For IgM, Sensitivity: 33.3% Specificity: 100%, PPV 100%, NPV = 99.2%. Seroprevalence obtained shows that about half of the study population is not immune against T. gondii and requires regular serological monitoring until delivery. According to these results, and given the needs of toxoplasmosis diagnosis on the field characterized by an important decrease of immunized women, this test may be recommended in the laboratory diagnosis of toxoplasmosis in peripheral levels of the health pyramid.

  16. [The primary application of direct rapid immunohistochemical test to rabies diagnosis in China].

    Science.gov (United States)

    Tao, Xiao-Yan; Niezgoda, Michael; Du, Jia-Liang; Li, Hao; Wang, Xiao-Guang; Huang, Ying; Jiao, Yang; Cao, Lei; Tang, Qing; Liang, Guo-Dong

    2008-06-01

    Evaluation of the direct rapid immumohistochemical test (DRIT) for laboratory surveillance of rabies. 72 brain specimens of domestic dogs or patients collected from Guizhou, Guangxi, Hunan, Anhui, Jiangsu and Yunnan provinces were detected by conventional methods including Direct Fluorescent-antibody Assay (DFA) and Reverse Transcription Polymerase Chain Reaction (RT-PCR), and by DRIT which was newly developed in the Rabies Section of the Centers for Disease Control and Prevention in the United States. The sensitivity and specificity of DRIT were evaluated by compare of the three results. By analysis of the index including cost of experiment, technique requirement and so on, the advancement and applicability of DRIT were discussed. Compared with DFA and RT-PCR, DRIT will be more applicable for laboratories with limited funds and weak techniques because of its lower cost needed and simpler techniques required while its sensitivity and specificity are equal to the other two methods. DRIT is more valuable in rabies diagnosis and more applicable for extension and popularization in rabies laboratory surveillance in local CDC.

  17. Cross-reactive antibodies in convalescent SARS patients' sera against the emerging novel human coronavirus EMC (2012) by both immunofluorescent and neutralizing antibody tests.

    Science.gov (United States)

    Chan, Kwok-Hung; Chan, Jasper Fuk-Woo; Tse, Herman; Chen, Honglin; Lau, Candy Choi-Yi; Cai, Jian-Piao; Tsang, Alan Ka-Lun; Xiao, Xincai; To, Kelvin Kai-Wang; Lau, Susanna Kar-Pui; Woo, Patrick Chiu-Yat; Zheng, Bo-Jiang; Wang, Ming; Yuen, Kwok-Yung

    2013-08-01

    A severe acute respiratory syndrome (SARS)-like disease due to a novel betacoronavirus, human coronavirus EMC (HCoV-EMC), has emerged recently. HCoV-EMC is phylogenetically closely related to Tylonycteris-bat-coronavirus-HKU4 and Pipistrellus-bat-coronavirus-HKU5 in Hong Kong. We conducted a seroprevalence study on archived sera from 94 game-food animal handlers at a wild life market, 28 SARS patients, and 152 healthy blood donors in Southern China to assess the zoonotic potential and evidence for intrusion of HCoV-EMC and related viruses into humans. Anti-HCoV-EMC and anti-SARS-CoV antibodies were detected using screening indirect immunofluorescence (IF) and confirmatory neutralizing antibody tests. Two (2.1%) animal handlers had IF antibody titer of ≥ 1:20 against both HCoV-EMC and SARS-CoV with neutralizing antibody titer of SARS patients had significant IF antibody titers with 7/28 (25%) having anti-HCoV-EMC neutralizing antibodies at low titers which significantly correlated with that of HCoV-OC43. Bioinformatics analysis demonstrated a significant B-cell epitope overlapping the heptad repeat-2 region of Spike protein. Virulence of SARS-CoV over other betacoronaviruses may boost cross-reactive neutralizing antibodies against other betacoronaviruses. Convalescent SARS sera may contain cross-reactive antibodies against other betacoronaviruses and confound seroprevalence study for HCoV-EMC. Copyright © 2013 The British Infection Association. Published by Elsevier Ltd. All rights reserved.

  18. Rapid Detection and Isolation of Escherichia coli O104:H4 from Milk Using Monoclonal Antibody-coated Magnetic Beads

    Science.gov (United States)

    Luciani, Mirella; Di Febo, Tiziana; Zilli, Katiuscia; Di Giannatale, Elisabetta; Armillotta, Gisella; Manna, Laura; Minelli, Fabio; Tittarelli, Manuela; Caprioli, Alfredo

    2016-01-01

    Monoclonal antibodies (MAbs) specific for the lipopolysaccharide (LPS) of Escherichia coli O104:H4 were produced by fusion of Sp2/O-Ag-14 mouse myeloma cells with spleen cells of Balb/c mice, immunized with heat-inactivated and sonicated E. coli O104:H4 bacterial cells. Four MAbs specific for the E. coli O104:H4 LPS (1E6G6, 1F4C9, 3G6G7, and 4G10D2) were characterized and evaluated for the use in a method for the detection of E. coli O104:H4 in milk samples that involves antibody conjugation to magnetic microbeads to reduce time and increase the efficiency of isolation. MAb 1E6G6 was selected and coupled to microbeads, then used for immuno-magnetic separation (IMS); the efficiency of the IMS method for E. coli O104:H4 isolation from milk was evaluated and compared to that of the EU RL VTEC conventional culture-based isolation procedure. Milk suspensions also containing other pathogenic bacteria that could potentially be found in milk (Campylobacter jejuni, Listeria monocytogenes, and Staphylococcus aureus) were also tested to evaluate the specificity of MAb-coated beads. Beads coated with MAb 1E6G6 showed a good ability to capture the E. coli O104:H4, even in milk samples contaminated with other bacteria, with a higher number of E. coli O104:H4 CFU reisolated in comparison with the official method (121 and 41 CFU, respectively, at 103 E. coli O104:H4 initial load; 19 and 6 CFU, respectively, at 102 E. coli O104:H4 initial load; 1 and 0 CFU, respectively, at 101 E. coli O104:H4 initial load). The specificity was 100%. PMID:27379071

  19. Field Evaluation of the Determine Rapid Human Immunodeficiency Virus Diagnostic Test in Honduras and the Dominican Republic

    Science.gov (United States)

    Palmer, Carol J.; Dubon, Jose M.; Koenig, Ellen; Perez, Eddy; Ager, Arba; Jayaweera, Dushyantha; Cuadrado, Raul R.; Rivera, Ada; Rubido, Alex; Palmer, Dennis A.

    1999-01-01

    Rapid detection of human immunodeficiency virus (HIV) infection can result in improved patient care and/or faster implementation of public health preventive measures. A new rapid test, Determine (Abbott, Abbott Park, Ill.), detects HIV type 1 (HIV-1) and HIV-2 antibodies within 15 min by using 50 μl of serum or plasma. No specialized equipment or ancillary supplies are required, and results are read visually. A positive result is noted by the appearance of a red line. An operational control (red line) indicates proper test performance. We evaluated the Determine rapid HIV detection test with a group of well-characterized serum samples (CD4 counts and viral loads were known) and serum samples from HIV-positive individuals at field sites in Honduras and the Dominican Republic. In the field evaluations, the results obtained by the Determine assay were compared to those obtained by local in-country HIV screening procedures. We evaluated serum from 100 HIV-positive patients and 66 HIV-negative patients. All samples gave the expected results. In a companion study, 42 HIV-positive samples from a Miami, Fla., serum bank were tested by the Determine assay. The samples had been characterized in terms of CD4 counts and viral loads. Fifteen patients had CD4 counts 200 cells/mm3. Viral loads ranged from 630 to 873,746 log10 copies/ml. All samples from the Miami serum bank were positive by the Determine test. Combined results from the multicenter studies indicated that the correct results were obtained by the Determine assay for 100% (142 of 142) of the HIV-positive serum samples and 100% (66 of 66) of the HIV-negative serum samples. The Determine test was simple to perform and the results were easy to interpret. The Determine test provides a valuable new method for the rapid identification of HIV-positive individuals, especially in developing countries with limited laboratory infrastructures. PMID:10523577

  20. Validation of serological tests for the detection of antibodies against Treponema pallidum in nonhuman primates.

    Science.gov (United States)

    Knauf, Sascha; Dahlmann, Franziska; Batamuzi, Emmanuel K; Frischmann, Sieghard; Liu, Hsi

    2015-03-01

    There is evidence to suggest that the yaws bacterium (Treponema pallidum ssp. pertenue) may exist in non-human primate populations residing in regions where yaws is endemic in humans. Especially in light of the fact that the World Health Organizaiton (WHO) recently launched its second yaws eradication campaign, there is a considerable need for reliable tools to identify treponemal infection in our closest relatives, African monkeys and great apes. It was hypothesized that commercially available serological tests detect simian anti-T. pallidum antibody in serum samples of baboons, with comparable sensitivity and specificity to their results on human sera. Test performances of five different treponemal tests (TTs) and two non-treponemal tests (NTTs) were evaluated using serum samples of 57 naturally T. pallidum-infected olive baboons (Papio anubis) from Lake Manyara National Park in Tanzania. The T. pallidum particle agglutination assay (TP-PA) was used as a gold standard for comparison. In addition, the overall infection status of the animals was used to further validate test performances. For most accurate results, only samples that originated from baboons of known infection status, as verified in a previous study by clinical inspection, PCR and immunohistochemistry, were included. All tests, TTs and NTTs, used in this study were able to reliably detect antibodies against T. pallidum in serum samples of infected baboons. The sensitivity of TTs ranged from 97.7-100%, while specificity was between 88.0-100.0%. The two NTTs detected anti-lipoidal antibodies in serum samples of infected baboons with a sensitivity of 83.3% whereas specificity was 100%. For screening purposes, the TT Espline TP provided the highest sensitivity and specificity and at the same time provided the most suitable format for use in the field. The enzyme immune assay Mastblot TP (IgG), however, could be considered as a confirmatory test.

  1. Validation of serological tests for the detection of antibodies against Treponema pallidum in nonhuman primates.

    Directory of Open Access Journals (Sweden)

    Sascha Knauf

    2015-03-01

    Full Text Available There is evidence to suggest that the yaws bacterium (Treponema pallidum ssp. pertenue may exist in non-human primate populations residing in regions where yaws is endemic in humans. Especially in light of the fact that the World Health Organizaiton (WHO recently launched its second yaws eradication campaign, there is a considerable need for reliable tools to identify treponemal infection in our closest relatives, African monkeys and great apes. It was hypothesized that commercially available serological tests detect simian anti-T. pallidum antibody in serum samples of baboons, with comparable sensitivity and specificity to their results on human sera. Test performances of five different treponemal tests (TTs and two non-treponemal tests (NTTs were evaluated using serum samples of 57 naturally T. pallidum-infected olive baboons (Papio anubis from Lake Manyara National Park in Tanzania. The T. pallidum particle agglutination assay (TP-PA was used as a gold standard for comparison. In addition, the overall infection status of the animals was used to further validate test performances. For most accurate results, only samples that originated from baboons of known infection status, as verified in a previous study by clinical inspection, PCR and immunohistochemistry, were included. All tests, TTs and NTTs, used in this study were able to reliably detect antibodies against T. pallidum in serum samples of infected baboons. The sensitivity of TTs ranged from 97.7-100%, while specificity was between 88.0-100.0%. The two NTTs detected anti-lipoidal antibodies in serum samples of infected baboons with a sensitivity of 83.3% whereas specificity was 100%. For screening purposes, the TT Espline TP provided the highest sensitivity and specificity and at the same time provided the most suitable format for use in the field. The enzyme immune assay Mastblot TP (IgG, however, could be considered as a confirmatory test.

  2. EU-approved rapid tests might underestimate bovine spongiform encephalopathy infection in goats

    NARCIS (Netherlands)

    Meloni, Daniela; Bozzetta, Elena; Langeveld, Jan P.M.; Groschup, Martin H.; Goldmann, Wilfred; Andrèoletti, Olivier; Lantier, Isabelle; Keulen, Van Lucien; Bossers, Alex; Pitardi, Danilo; Nonno, Romolo; Sklaviadis, Theodoros; Ingravalle, Francesco; Peletto, Simone; Colussi, Silvia; Acutis, Pier Luigi

    2017-01-01

    We report the diagnostic sensitivity of 3 EU-approved rapid tests (ELISAs; 1 from IDEXX and 2 from Bio-Rad) for the detection of transmissible spongiform encephalopathy diseases in goats. Ninety-eight goat brainstem samples were tested. All the rapid tests had 100% specificity and ≥80% sensitivity,

  3. An Analysis of Test And Evaluation in Rapid Acquisition Programs

    Science.gov (United States)

    2015-12-01

    Outfits DT Developmental Testing DT&E Development Test and Evaluation DTC Developmental Test Command E3 Electromagnetic Environmental Effects...by the OEM and evaluated by the Communication-Electronics Command (CECOM) Safety Office and the former Developmental Test Command ( DTC ) covering all...Force Management School AMC Army Materiel Command AOA Analysis of Alternatives AOR Area of Operation APC Acquisition Program Candidates APG Aberdeen

  4. Evaluation of a multiple food specific IgE antibody test compared to parental perception, allergy skin tests and RAST.

    Science.gov (United States)

    Adler, B R; Assadullahi, T; Warner, J A; Warner, J O

    1991-11-01

    This study was set up to evaluate the food panel of a multiple specific IgE antibody assay in 67 atopic asthmatic children by comparing it to the conventional radioallergosorbent test (RAST) and skin-prick tests (SPT) and then comparing the results of these investigations with the parents' perceptions of food related problems. Fifteen food specific IgE antibodies were measured using the multiple chemiluminescence assay (MAST-CLA). IgE antibodies to five of these food allergens were also measured by conventional RAST and SPTs were performed in 43 using 11 standardized food extracts matched to the multiple allergosorbent chemiluminescent assay (MAST-CLA) profile. SPT and MAST-CLA results showed good agreement with one another, range 68.8-96.7% (average 87%), with significant correlation for most allergens tested. MAST-CLA was discrepant with RAST and/or SPTs in 58/210 (27.6%). A questionnaire was sent to the parents to determine their perception of food related symptoms. Sixty-two (92%) questionnaire replies were received, of which 56% reported symptoms with food. The most frequent symptom perceived to be due to food intolerance was behavioural disturbance. The commonest foods implicated were additives (39%), egg (27%), milk (26%), chocolate (23%) and orange (15%). History, SPT, MAST-CLA and RAST were compared for five allergens in 42 patients (210 values). In 14/210 (6.7%), all the tests were negative despite reported symptoms. Conversely in 49/210 (23.3%) at least one test was positive without symptoms. This study did not support a benefit of multipole testing instead of individually selected RASTs or SPTs.(ABSTRACT TRUNCATED AT 250 WORDS)

  5. Screening tests for antibodies to cytomegalovirus: an evaluation of five commercial products.

    Science.gov (United States)

    Grint, P C; Ronalds, C J; Kangro, H O; Campbell-Benzie, A; Ward, F; Hardiman, A E; Heath, R B

    1985-09-01

    Four hundred and ninety two samples of serum from blood donors were screened for the presence of antibodies specific to cytomegalovirus using radioimmunoassay, a modified complement fixation test, and five commercially available tests: the Cetus CMV IHA, Abbott CMV total AB EIA, Cytomegalisa Stat EIA, Enzygnost EIA, and Virenz G-CMV EIA. A wide variation in results was found, with only 53.5% of the sera giving total concordance by all methods. Rates of seropositivity in the different tests ranged from 34.9% to 59.3%, with sensitivities ranging from 75.2% to 99.1% compared with the radioimmunoassay. Of 211 sera which gave positive results with four or more of the tests, none was negative by the radioimmunoassay and Abbott EIA, three were negative in Cetus IHA and Enzygnost EIA, and 11 were negative in the modified complement fixation test. Virenz G and Cytomegalisa Stat EIAs, however, gave 40 (19%) and 49 (23.2%), respectively, as negative. The results confirmed the reliability of the radioimmunoassay for the detection of the antibody status to CMV, but this test is too elaborate for a screening procedure. The Abbott EIA and Cetus IHA were found to be the most suitable for this purpose in spite of high false positive rates.

  6. Should we systematically test patients with clinically isolated syndrome for auto-antibodies?

    Science.gov (United States)

    Negrotto, Laura; Tur, Carmen; Tintoré, Mar; Arrambide, Georgina; Sastre-Garriga, Jaume; Río, Jordi; Comabella, Manuel; Nos, Carlos; Galán, Ingrid; Vidal-Jordana, Angela; Simon, Eva; Castilló, Joaquín; Palavra, Filipe; Mitjana, Raquel; Auger, Cristina; Rovira, Àlex; Montalban, Xavier

    2015-12-01

    Several autoimmune diseases (ADs) can mimic multiple sclerosis (MS). For this reason, testing for auto-antibodies (auto-Abs) is often included in the diagnostic work-up of patients with a clinically isolated syndrome (CIS). The purpose was to study how useful it was to systematically determine antinuclear-antibodies, anti-SSA and anti-SSB in a non-selected cohort of CIS patients, regarding the identification of other ADs that could represent an alternative diagnosis. From a prospective CIS cohort, we selected 772 patients in which auto-Ab levels were tested within the first year from CIS. Baseline characteristics of auto-Ab positive and negative patients were compared. A retrospective revision of clinical records was then performed in the auto-Ab positive patients to identify those who developed ADs during follow-up. One or more auto-Ab were present in 29.4% of patients. Only 1.8% of patients developed other ADs during a mean follow-up of 6.6 years. In none of these cases the concurrent AD was considered the cause of the CIS. In all cases the diagnosis of the AD resulted from the development of signs and/or symptoms suggestive of each disease. Antinuclear-antibodies, anti-SSA and anti-SSB should not be routinely determined in CIS patients but only in those presenting symptoms suggestive of other ADs. © The Author(s), 2015.

  7. Effects of heat inactivation on HIV antibody screening and confirmatory test systems.

    Science.gov (United States)

    Fipps, D R; Damato, J J; Burke, D S

    1988-06-01

    In order to evaluate the effect of heat inactivation on serum undergoing testing for HIV antibody, 100 heat-inactivated and nonheat-inactivated serum samples were tested by two modifications of Abbott's screening assays for human T-cell lymphotropic virus type-III (lot numbers 1037 and 3036) and by two confirmatory assays (Cambridge BioScience CBre3-EIA; Damon Corporation Western blot). The samples consisted of 75 HIV antibody-negative and 25 HIV antibody-positive sera. The specimens were divided into two equal aliquots. One set was not subjected to heat inactivation, while the others were subjected to heat inactivation at 56 degrees C for 30 min. Heat inactivation had no significant effect on the HIV-position sera; however, heat-inactivated, negative sera evaluated by Abbott lot numbers 1037 and 3036 resulted in false-positive rates of 8% and 7%, respectively. No false positives were generated by the two confirmatory assays; however, the CBre3-EIA recombinant envelope protein assay had a significantly increased optical density reading following heat inactivation of the negative sera. The Western blot procedure used in the study was not affected by heat inactivation.

  8. Early infliximab antibody testing does not prevent infusion reactions when reinitiating infliximab

    Directory of Open Access Journals (Sweden)

    Joseph D. Feuerstein

    2016-08-01

    Full Text Available Infliximab drug level checking has started to revolutionize the treatment of inflammatory bowel disease, allowing for more accurate dosing. Recently, Brandse and colleagues and Gagniere and colleagues both noted the potential benefit of a re-introduction of infliximab after prior failure in patients with Crohn’s disease. Unfortunately though, approximately 1/3 of patients stopped the drug due to side effects of the attempted retreatment from infusion reactions. In their study, they also noted that concomitant usage of a thiopurine did not provide any additional benefit. Presumably, majority of these reactions are secondary to antibody formation to infliximab. In order to reduce the risk of infusion reactions, we present a case of a patient with Crohn’s disease who was retried on infliximab and had antibody testing after the first dose to assess if it would be safe to continue the drug, as most infusion reactions occur at the second dose.

  9. Developmental toxicity testing of monoclonal antibodies: an enhanced pre- and postnatal study design option.

    Science.gov (United States)

    Stewart, Jane

    2009-09-01

    For many monoclonal antibodies (mAb), the preferred species for general and reproductive safety testing is often the cynomolgus monkey. This article describes the rationale for combining the traditional "segmented" embryofetal development study with the pre- and postnatal development (PPND) study into a single "enhanced" PPND study design in the cynomolgus monkey where a single cohort of animals is exposed throughout gestation and allowed to give birth naturally. The proposed "enhanced" PPND study design evaluates all the stages of the traditional two study design using fewer animals. It also assesses the functional consequences of mid to late gestational exposure. This is of particular relevance to the risk assessment of monoclonal antibodies where fetal exposure to maternal IgG increases as pregnancy progresses and where morphologic examination of a pre-term fetus may not be adequate to reveal the presence of adverse effects on functional development of key target organs.

  10. An imaging diagnosis of cerebral paragonimiasis: CT and MR findings and correlation with ELISA antibody test

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Kee Hyun; Cha, Sang Hoon; Han, Moon Hee; Kim, Hong Dae; Cho, Seung Yull; Kong, Yoon; Kang, Hyung Keun; Kim, Myung Soon [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    1993-05-15

    To evaluate the CT and MR findings of cerebral paragonimiasis(PW) and to assess the diagnostic value of the specific antibody test by enzyme-linked immunosorbent assay(ELISA) for PW, 55 CT scans and 13 MR images of 57 patients with cerebral PW were reviewed retrospectively, and correlated with the serum/ CSF antibody levels. We divided the patients into three groups, early active (n=21), chronic(n=32), and combined stage(n=4), on the basis of CT/MR findings. In the groups of early active stage the most common and characteristic finding was multiple, conglomerated, ring-like enhancing lesion in the unilateral cerebral hemisphere, which was seen in 52% on CT and 44% on MR. Other non-specific findings included a solitary ring-like or irregular enhancing lesions, ill-defined low density lesions without enhancement, localized hemorrhage with or without enhancing lesions. In the group of chronic stage, there were multiple calcifications of various shapes, most commonly 1-2 cm sized round shape, and associated encephalomalacia. MR was superior to CT in detecting hemorrhage and in characterizing the central contents of ring-shaped calcifications, while it was inferior to CT in identifying small calcifications. Antibody levels of serum and CSF were positive in 86% and 82% in early active group, and in 48% and 31% in chronic stage,retrospectively.The positive rate was significantly different between the two groups (P=0.001). CT/MR findings were characteristic in only approximately half the cases in early active cerebral PW which can be cured by Praziquantel therapy. Therefore, antibody test by ELISA is recommended as a complementary tool, particularly in patients with non-specific imaging findings.

  11. Comparison of two rapid tests for anti-phenolic glycolipid-I serology in Brazil and Nepal

    Directory of Open Access Journals (Sweden)

    Mariane Martins de Araújo Stefani

    2012-12-01

    Full Text Available The diagnosis of leprosy continues to be based on clinical symptoms and early diagnosis and treatment are critical to preventing disability and transmission. Sensitive and specific laboratory tests are not available for diagnosing leprosy. Despite the limited applicability of anti-phenolic glycolipid-I (PGL-I serology for diagnosis, it has been suggested as an additional tool to classify leprosy patients (LPs for treatment purposes. Two formats of rapid tests to detect anti-PGL-I antibodies [ML immunochromatography assay (ICA and ML Flow] were compared in different groups, multibacillary patients, paucibacillary patients, household contacts and healthy controls in Brazil and Nepal. High ML Flow intra-test concordance was observed and low to moderate agreement between the results of ML ICA and ML Flow tests on the serum of LPs was observed. LPs were "seroclassified" according to the results of these tests and the seroclassification was compared to other currently used classification systems: the World Health Organization operational classification, the bacilloscopic index and the Ridley-Jopling classification. When analysing the usefulness of these tests in the operational classification of PB and MB leprosy for treatment and follow-up purposes, the ML Flow test was the best point-of-care test for subjects in Nepal and despite the need for sample dilution, the ML ICA test yielded better performance among Brazilian subjects. Our results identified possible ways to improve the performance of both tests.

  12. Portable Rapid Test Fuel Tank Leak Detection System

    Science.gov (United States)

    2010-04-01

    the site-specific test parameters and selects the “Start Test” icon . Leak test final results can be obtained in less than 5 hours. 3.0 PROTOTYPE...the reference tube into section lengths of less than 7 feet for shipping, and 3) downsizing the reference tube diameter to reduce weight and for

  13. Simultaneous Quantitative Detection of Helicobacter Pylori Based on a Rapid and Sensitive Testing Platform using Quantum Dots-Labeled Immunochromatiographic Test Strips

    Science.gov (United States)

    Zheng, Yu; Wang, Kan; Zhang, Jingjing; Qin, Weijian; Yan, Xinyu; Shen, Guangxia; Gao, Guo; Pan, Fei; Cui, Daxiang

    2016-02-01

    Quantum dots-labeled urea-enzyme antibody-based rapid immunochromatographic test strips have been developed as quantitative fluorescence point-of-care tests (POCTs) to detect helicobacter pylori. Presented in this study is a new test strip reader designed to run on tablet personal computers (PCs), which is portable for outdoor detection even without an alternating current (AC) power supply. A Wi-Fi module was integrated into the reader to improve its portability. Patient information was loaded by a barcode scanner, and an application designed to run on tablet PCs was developed to handle the acquired images. A vision algorithm called Kmeans was used for picture processing. Different concentrations of various human blood samples were tested to evaluate the stability and accuracy of the fabricated device. Results demonstrate that the reader can provide an easy, rapid, simultaneous, quantitative detection for helicobacter pylori. The proposed test strip reader has a lighter weight than existing detection readers, and it can run for long durations without an AC power supply, thus verifying that it possesses advantages for outdoor detection. Given its fast detection speed and high accuracy, the proposed reader combined with quantum dots-labeled test strips is suitable for POCTs and owns great potential in applications such as screening patients with infection of helicobacter pylori, etc. in near future.

  14. A Rapid Method to Characterize Mouse IgG Antibodies and Isolate Native Antigen Binding IgG B Cell Hybridomas.

    Directory of Open Access Journals (Sweden)

    Haolin Liu

    Full Text Available B cell hybridomas are an important source of monoclonal antibodies. In this paper, we developed a high-throughput method to characterize mouse IgG antibodies using surface plasmon resonance technology. This assay rapidly determines their sub-isotypes, whether they bind native antigen and their approximate affinities for the antigen using only 50 μl of hybridoma cell culture supernatant. Moreover, we found that mouse hybridomas secreting IgG antibodies also have membrane form IgG expression without Igα. Based on this surface IgG, we used flow cytometry to isolate rare γ2a isotype switched variants from a γ2b antibody secreting hybridoma cell line. Also, we used fluorescent antigen to single cell sort antigen binding hybridoma cells from bulk mixture of fused hybridoma cells instead of the traditional multi-microwell plate screening and limiting dilution sub-cloning thus saving time and labor. The IgG monoclonal antibodies specific for the native antigen identified with these methods are suitable for in vivo therapeutic uses, but also for sandwich ELISA assays, histology, flow cytometry, immune precipitation and x-ray crystallography.

  15. Development of a Rapid Immunodiagnostic Test for Pork Components in Raw Beef and Chicken Meats: a Preliminary Study

    Directory of Open Access Journals (Sweden)

    S. N. Depamede

    2011-08-01

    Full Text Available A rapid immunodiagnostic test that provides visual evidence of the presence of pork components in raw beef and chicken meats was developed. Colloidal gold was prepared and conjugated with anti-Swine IgG polyclonal antibody. Immunochromatographic test strips were produced, and then were used to test laboratory adulterated raw meat samples. The samples consisted adulteration meat, immunodiagnostic, pork, rapid test of pork-in-beef, or pork-in-chicken at 1/0; 1/100; 1/1,000; 1/5,000; 1/10,000 (w/w adulteration levels that were extracted in phosphate-buffered saline. Raw beef and chicken meats without pork were included as controls. Analysis was completed in 10 min. Detection limit was 1/5,000 (w/w, although 1/10,000 was also observed. This immunodiagnostic tests can be conveniently applied to detect low levels of pork components in raw beef and chicken meat products. For the commercial purposes, further studies need to be carried out.

  16. Preferences for rapid point-of-care HIV testing in Nova Scotia, Canada.

    Science.gov (United States)

    Lewis, Nathaniel M; Gahagan, Jacqueline C; Stein, Carlye

    2013-05-01

    Rapid point-of-care (POC) testing for HIV has been shown to increase the uptake of testing, rates of clients receiving test results, numbers of individuals aware of their status and timely access to care for those who test positive. In addition, several studies have shown that rapid POC testing for HIV is highly acceptable to clients in a variety of clinical and community-based health care settings. Most acceptability studies conducted in North America, however, have been conducted in large, urban environments where concentrations of HIV testing sites and testing innovations are greatest. Using a survey of client preferences at a sexual health clinic in Halifax, Nova Scotia, we suggest that HIV test seekers living in a region outside of Canada's major urban HIV epicentres find rapid POC testing highly acceptable. We compare the results of the Halifax survey with existing acceptability studies of rapid POC HIV testing in North America and suggest ways in which it might be of particular benefit to testing clients and potential clients in Nova Scotia and other regions of Canada that currently have few opportunities for anonymous or rapid testing. Overall, we found that rapid POC HIV testing was highly desirable at this study site and may serve to overcome many of the challenges associated with HIV prevention and testing outside of well-resourced metropolitan environments.

  17. The impact of commercial rapid respiratory virus diagnostic tests on patient outcomes and health system utilization.

    Science.gov (United States)

    Ko, Fiona; Drews, Steven J

    2017-10-01

    Acute respiratory tract infections due to influenza A/B and respiratory syncytial virus (RSV) are major causes of morbidity and mortality globally. Rapid tests for detection of these pathogens include antigen detection point of care tests (POC) and newer easy to use molecular tests. From experience, these assays improve both laboratory workflow and assay interpretation issues. However, the question of the benefits of using rapid test technology compared to routine laboratory testing for respiratory viral pathogens is still often asked. Areas covered: Specifically, this review aims to; 1) identify clinical/patient indicators that can be measured prior to and following the implementation of rapid diagnostic test for influenza and RSV, 2) provide multiple perspectives on the extent of impact of a rapid diagnostic test, including direct and indirect outcomes, and 3) identify the technological advancements in the development of rapid testing, demonstrating a timeline that transitions from antigen-based assays to molecular assays. Expert commentary: Key benefits to the use of either antigen-based or molecular rapid tests for patient care, patient flow within institutions, as well as laboratory utilization are identified. Due to improved test characteristics, the authors feel that rapid molecular tests have greater benefits than antigen-based detection methods.

  18. Validation of a commercially available cELISA test for canine neosporosis against an indirect fluorescent antibody test (IFAT).

    Science.gov (United States)

    Capelli, Gioia; Natale, Alda; Nardelli, Stefano; Frangipane di Regalbono, Antonio; Pietrobelli, Mario

    2006-03-16

    A commercially available competitive enzyme-linked immunosorbent assay (cELISA, VMRD) was validated for the detection of Neospora caninum antibodies in the serum of dogs, using as a reference test an indirect fluorescent antibody test (IFAT, Fuller). A partial verification approach was used. A total of 618 dogs were screened with cELISA and a subset of positive and negative sera (n=237) were then tested with IFAT. Naïve relative sensitivity (SE(nv)) and naïve relative specificity (SP(nv)) of cELISA were calculated and then corrected (SE(corr); SP(corr)) for studies with partial validation. Results showed a SE(nv) of 72% and a SP(nv) of 89.3%; corrected estimates showed a SE(corr) of 47% and a SP(corr) of 96%. ROC analysis showed that the cutoff recommended by the manufacturer (30%) corresponded to the highest naïve sensitivity (72%) combined with a good naïve specificity (90%) of cELISA. Corrected estimates of SE and SP for partial verification method revealed that SE of the cELISA is lower and SP is higher than naïve estimates. The results suggest to use this test for confirmation of a clinical suspicion of neosporosis, and to use some techniques for adjustment of misclassification in prevalence and risk-factor studies.

  19. Rapid Quantification of the Toxic Alga Prymnesium parvum in Natural Samples by Use of a Specific Monoclonal Antibody and Solid-Phase Cytometry

    DEFF Research Database (Denmark)

    West, N. J.; Bacchieri, R.; Hansen, Gert

    2006-01-01

    The increasing incidence of harmful algal blooms around the world and their associated health and economic effects require the development of methods to rapidly and accurately detect and enumerate the target species. Here we describe use of a solid-phase cytometer to detect and enumerate the toxi......-phase cytometer can be used to rapidly enumerate natural P. parvum cells and that it could be used to detect other toxic algae, with an appropriate antibody or DNA probe.......The increasing incidence of harmful algal blooms around the world and their associated health and economic effects require the development of methods to rapidly and accurately detect and enumerate the target species. Here we describe use of a solid-phase cytometer to detect and enumerate the toxic...... alga Prymnesium parvum in natural samples, using a specific monoclonal antibody and indirect immunofluorescence. The immunoglobulin G antibody 16E4 exhibited narrow specificity in that it recognized several P. parvum strains and a Prymnesium nemamethecum strain but it did not cross-react with P. parvum...

  20. Increased Sensitivity of a New Coagglutination Test for Rapid Identification of Haemophilus influenzae Type b

    OpenAIRE

    Grasso, Robert J.; West, Loyd A.; Holbrook, Nikki J.; Halkias, Demetrios G.; Paradise, Lois J.; Friedman, Herman

    1981-01-01

    A newly developed rapid coagglutination test for identifying Haemophilus influenzae type b organisms isolated from clinical specimens correlated 100% with the slide agglutination test but was 100- to 200-fold more sensitive.

  1. Immunochemical parameters of some commercial conjugates for the fluorescent treponemal antibody-absorption test.

    Science.gov (United States)

    Hunter, E F; Smith, J F; Lewis, J S; McGrew, B E; Schmale, J D

    1972-06-01

    Fluorescein-labeled anti-human globulins were examined to determine the need for standardization of conjugates used in the fluorescent treponemal antibody-absorption (FTA-ABS) test. Twenty-one of 33 conjugates submitted by commercial manufacturers to the Reagents Control Activity, Venereal Disease Research Laboratory, for evaluation in the FTA-ABS test were available for study. Conjugates, after evaluation in FTA-ABS performance tests, were examined by immunoelectrophoresis, by titration against immunoglobulins G and M (IgG, IgM) with FTA-ABS techniques, and by the biuret protein and fluorescein diacetate methods for determining fluorescein to protein (F/P) ratios. The conjugates were predominately anti-IgG globulin with anti-light-chain activity. Differences were noted in the ability of some conjugates to detect IgM antibody. The F/P ratios of those conjugates that could be determined varied from 2.6 to 17.8 mug of fluorescein per mg of protein. The need to identify and standardize both the immunologic capabilities and the optimum F/P ratio for FTA-ABS test conjugates is presented.

  2. Comparative assay of fluorescent antibody test results among twelve European National Reference Laboratories using various anti-rabies conjugates

    DEFF Research Database (Denmark)

    Robardet, E.; Andrieu, S.; Rasmussen, Thomas Bruun

    2013-01-01

    Twelve National Reference Laboratories (NRLs) for rabies have undertaken a comparative assay to assess the comparison of fluorescent antibody test (FAT) results using five coded commercial anti-rabies conjugates (Biorad, Bioveta, Fujirebio, Millipore, and SIFIN conjugates). Homogenized positive...

  3. DARPA Antibody Technology Program Standardized Test Bed for Antibody Characterization: Characterization of an MS2 sdAb Produced by U.S. Naval Research Laboratory

    Science.gov (United States)

    2016-10-01

    Functioning as an independent testing laboratory for this program, the U.S. Army Edgewood Chemical Biological Center (ECBC; Aberdeen Proving Ground ...Tm should predict the results of subsequent ELISA and surface plasmon resonance (SPR) thermostability testing. A Tm above 70 °C predicts that the...antibody. 5 accumulated mass (bound proteins) adsorbs on the surface. Therefore, if binding occurs, the resonance angle (SPR angle) changes, and this

  4. A new rapid home test for faecal calprotectin in ulcerative colitis

    DEFF Research Database (Denmark)

    Elkjaer, M; Burisch, Johan; Hansen, V Voxen

    2010-01-01

    Enzyme-linked immunosorbent assay (ELISA) is a time-consuming method for the measurement of faecal calprotectin. Two new quantitative rapid tests have been developed.......Enzyme-linked immunosorbent assay (ELISA) is a time-consuming method for the measurement of faecal calprotectin. Two new quantitative rapid tests have been developed....

  5. Centrifuge modeling of rapid load tests with open-ended piles

    NARCIS (Netherlands)

    Nguyen, T.C.; Van Lottum, H.; Holscher, P.; Van Tol, A.F.

    2012-01-01

    Rapid and static load tests were conducted on open-ended and close-ended piles in the Deltares GeoCentriflige. hi flight, a pile was driven into the soil. Both fme-grained sand and silt beds were tested. Both the rapid and static soil resistances o f a close-ended pile were higher than the soil

  6. Combined rapid (TUBEX test for typhoid-paratyphoid A fever based on strong anti-O12 response: design and critical assessment of sensitivity.

    Directory of Open Access Journals (Sweden)

    Meiying Yan

    Full Text Available Rapid diagnostics can be accurate but, often, those based on antibody detection for infectious diseases are unwittingly underrated for various reasons. Herein, we described the development of a combined rapid test for two clinically-indistinguishable bacterial diseases, typhoid and paratyphoid A fever, the latter fast emerging as a global threat. By using monoclonal antibodies (mAbs to bacterial antigens of known chemical structures as probes, we were able to dissect the antibody response in patients at the level of monosaccharides. Thus, a mAb specific for a common lipopolysaccharide antigen (O12 found in both the causative organisms was employed to semi-quantify the amounts of anti-O12 antibodies present in both types of patients in an epitope-inhibition particle-based (TUBEX immunoassay. This colorimetric assay detected not only anti-O12 antibodies that were abundantly produced, but also, by steric hindrance, antibodies to an adjoining epitope (O9 or O2 in the typhoid or paratyphoid bacillus, respectively. Sensitivity and, particularly, reaction intensities, were significantly better than those obtained using an anti-O9 or anti-O2 mAb-probe in the examination of paired sera from 22 culture-confirmed typhoid patients (sensitivity, 81.8% vs 75.0% or single sera from 36 culture-confirmed paratyphoid patients (52.8% vs 28.6, respectively. Importantly, sensitivity was better (97.1% for typhoid, 75.0% for paratyphoid if allowance was made for the absence of relevant antibodies in certain specimens as determined by an independent, objective assay (ELISA--such specimens might have been storage-denatured (especially the older paratyphoid samples or procured from non-responders. Benchmarking against ELISA, which revealed high concordance between the two tests, was useful and more appropriate than comparing with culture methods as traditionally done, since antibody tests and culture target slightly different stages of these diseases. Paired sera

  7. Magnetic Fe3O4@TiO2 Nanoparticles-based Test Strip Immunosensing Device for Rapid Detection of Phosphorylated Butyrylcholinesterase

    Energy Technology Data Exchange (ETDEWEB)

    Ge, Xiaoxiao; Zhang, Weiying; Lin, Yuehe; Du, Dan

    2013-12-15

    An integrated magnetic nanoparticles-based test-strip immunosensing device was developed for rapid and sensitive quantification of phosphorylated butyrylcholinesterase (BChE), the biomarker of exposure to organophosphous pesticides (OP), in human plasma. In order to overcome the difficulty in scarce availability of OP-specific antibody, here magnetic Fe3O4@TiO2 nanoparticles were used and adsorbed on the test strip through a small magnet inserted in the device to capture target OP-BChE through selective binding between TiO2 and OP moiety. Further recognition was completed by horseradish peroxidase (HRP) and anti-BChE antibody (Ab) co-immobilized gold nanoparticles (GNPs). Their strong affinities among Fe3O4@TiO2, OP-BChE and HRP/Ab-GNPs were characterized by quartz crystal microbalance (QCM), surface plasmon resonance (SPR) and square wave voltammetry (SWV) measurements. After cutting off from test strip, the resulted immunocomplex (HRP/Ab-GNPs/OP-BChE/Fe3O4@TiO2) was measured by SWV using a screen printed electrode under the test zone. Greatly enhanced sensitivity was achieved by introduction of GNPs to link enzyme and antibody at high ratio, which amplifies electrocatalytic signal significantly. Moreover, the use of test strip for fast immunoreactions reduces analytical time remarkably. Coupling with a portable electrochemical detector, the integrated device with advanced nanotechnology displays great promise for sensitive, rapid and in-filed on-site evaluation of OP poisoning.

  8. Peroxidase antibody test for mucocutaneous leishmaniasis serology performance indexes and comparison with a fluorescent antibody test: Comparação com o desempenho da reação de imunofluorescência

    Directory of Open Access Journals (Sweden)

    Beatriz J. Celeste

    1988-12-01

    Full Text Available Performance indexes of the peroxidase antibody test were compared to that of the fluorescent antibody test. The peroxidase antibody test had a statistically higher sensitivity and negative predictive value and a higher efficiency than the fluorescent antibody test but its specificity and positive predictive value were within the 95% confidence limits for the values found for the fluorescent antibody test. Such differences did not change when Chagas' disease and visceral leishmaniasis sera were included in index calculations. Statistical analysis showed that the two tests have a substantial degree of agreement but the immunofluorescent test had a specificity index and a positive predictive value equal to 100.0% when Chagas' disease and visceral leishmaniasis sera were not included in the calculations of the performance index; in this instance, a positive test result equals a disclosure of the disease attribute due to the inexistence of false positive results. The enzyme/ protein ratio of the peroxidase conjugate, resulting in heavy or light-labeled conjugates may pose technical problems to its use in serology tests.

  9. Determination of HIV status in African adults with discordant HIV rapid tests

    Science.gov (United States)

    Fogel, Jessica M.; Piwowar-Manning, Estelle; Donohue, Kelsey; Cummings, Vanessa; Marzinke, Mark A.; Clarke, William; Breaud, Autumn; Fiamma, Agnès; Donnell, Deborah; Kulich, Michal; Mbwambo, Jessie K. K.; Richter, Linda; Gray, Glenda; Sweat, Michael; Coates, Thomas J.; Eshleman, Susan H.

    2015-01-01

    Background In resource-limited settings, HIV infection is often diagnosed using two rapid tests. If the results are discordant, a third tie-breaker test is often used to determine HIV status. This study characterized samples with discordant rapid tests and compared different testing strategies for determining HIV status in these cases. Methods Samples were previously collected from 173 African adults in a population-based survey who had discordant rapid test results. Samples were classified as HIV positive or HIV negative using a rigorous testing algorithm that included two fourth-generation tests, a discriminatory test, and two HIV RNA tests. Tie-breaker tests were evaluated, including: rapid tests (one performed in-country), a third-generation enzyme immunoassay (EIA), and two fourth-generation tests. Selected samples were further characterized using additional assays. Results Twenty-nine (16.8%) samples were classified as HIV positive; 24 (82.8%) of those samples had undetectable HIV RNA. Antiretroviral drugs were detected in one sample. Sensitivity was 8.3%–43% for the rapid tests; 24.1% for the third-generation EIA; 95.8% and 96.6% for the fourth-generation tests. Specificity was lower for the fourth-generation tests than the other tests. Accuracy ranged from 79.5–91.3%. Conclusions In this population-based survey, most HIV-infected adults with discordant rapid tests were virally suppressed without antiretroviral drugs. Use of individual assays as tie-breaker tests was not a reliable method for determining HIV status in these individuals. More extensive testing algorithms that use a fourth-generation screening test with a discriminatory test and HIV RNA test are preferable for determining HIV status in these cases. PMID:25835607

  10. Efficacy of a Direct Rapid Immunohistochemical Test (DRIT) For ...

    African Journals Online (AJOL)

    Rabies is an acute, infectious disease mostly transmitted through bites from an infected animal. Dogs majorly transmit rabies to humans. Human rabies is not curable once clinical signs commence, but can be prevented. The aim of this study was to find an appropriate diagnostic test suitable for use in Nigeria and other ...

  11. Comparison of Rapid Malaria Test and Laboratory Microscopy ...

    African Journals Online (AJOL)

    The Global (p.f) malaria test kit yielded 22 false negative and 35 false positive results when compared with microscopic findings. Only 18 cases shows true positive results. The specificity and sensitivity of the kit was 80% and 45% respectively when the parasite density is below 100 parasite/ µl. These results shows that ...

  12. Diagnostic accuracy of rapid urease test for the diagnosis of ...

    African Journals Online (AJOL)

    Background: The strong association of Helicobacter pylori (H. pylori) with dyspepsia has caused a major paradigm shift in patients' management. It has been observed that histology is usually employed as the routine test for the diagnosing H. pylori in centres where Oesophagogastroduodenoscopy (OGD) is available in ...

  13. Rapid determination of the hypoxanthine increase in ischemic exercise tests

    NARCIS (Netherlands)

    Bolhuis, P. A.; Zwart, R.; Bär, P. R.; de Visser, M.; van der Helm, H. J.

    1988-01-01

    After ischemic exercise tests, performed to detect glycogenoses or myoadenylate deaminase (EC 3.5.4.6) deficiency, the increases in serum lactate and ammonia usually are measured. Determination of hypoxanthine instead of ammonia can also be used to show myoadenylate deaminase deficiency, but HPLC of

  14. Development of an immunochromatographic strip test for rapid detection of melamine in raw milk, milk products and animal feed.

    Science.gov (United States)

    Li, Xiangmei; Luo, Pengjie; Tang, Shusheng; Beier, Ross C; Wu, Xiaoping; Yang, Lili; Li, Yanwei; Xiao, Xilong

    2011-06-08

    A simple, rapid and sensitive immunogold chromatographic strip test based on a monoclonal antibody was developed for the detection of melamine (MEL) residues in raw milk, milk products and animal feed. The limit of detection was estimated to be 0.05 μg/mL in raw milk, since the detection test line on the strip test completely disappeared at this concentration. The limit of detection was 2 μg/mL (or 2 μg/g) for milk drinks, yogurt, condensed milk, cheese, and animal feed and 1 μg/g for milk powder. Sample pretreatment was simple and rapid, and the results can be obtained within 3-10 min. A parallel analysis of MEL in 52 blind raw milk samples conducted by gas chromatography-mass spectrometry showed comparable results to those obtained from the strip test. The results demonstrate that the developed method is suitable for the onsite determination of MEL residues in a large number of samples.

  15. A rapid field test for sylvatic plague exposure in wild animals

    Science.gov (United States)

    Abbott, Rachel C.; Hudak, Robert; Mondesire, Roy; Baeten, Laurie A.; Russell, Robin E.; Rocke, Tonie E.

    2014-01-01

    Plague surveillance is routinely conducted to predict future epizootics in wildlife and exposure risk for humans. The most common surveillance method for sylvatic plague is detection of antibodies to Yersinia pestis F1 capsular antigen in sentinel animals, such as coyotes (Canis latrans). Current serologic tests for Y. pestis, hemagglutination (HA) test and enzyme-linked immunosorbent assay (ELISA), are expensive and labor intensive. To address this need, we developed a complete lateral flow device for the detection of specific antibodies to Y. pestis F1 and V antigens. Our test detected anti-F1 and anti-V antibodies in serum and Nobuto filter paper samples from coyotes, and in serum samples from prairie dogs (Cynomys ludovicianus), lynx (Lynx canadensis), and black-footed ferrets (Mustela nigripes). Comparison of cassette results for anti-F1 and anti-V antibodies with results of ELISA or HA tests showed correlations ranging from 0.68 to 0.98. This device provides an affordable, user-friendly tool that may be useful in plague surveillance programs and as a research tool.

  16. A rapid field test for sylvatic plague exposure in wild animals.

    Science.gov (United States)

    Abbott, Rachel C; Hudak, Robert; Mondesire, Roy; Baeten, Laurie A; Russell, Robin E; Rocke, Tonie E

    2014-04-01

    Plague surveillance is routinely conducted to predict future epizootics in wildlife and exposure risk for humans. The most common surveillance method for sylvatic plague is detection of antibodies to Yersinia pestis F1 capsular antigen in sentinel animals, such as coyotes (Canis latrans). Current serologic tests for Y. pestis, hemagglutination (HA) test and enzyme-linked immunosorbent assay (ELISA), are expensive and labor intensive. To address this need, we developed a complete lateral flow device for the detection of specific antibodies to Y. pestis F1 and V antigens. Our test detected anti-F1 and anti-V antibodies in serum and Nobuto filter paper samples from coyotes, and in serum samples from prairie dogs (Cynomys ludovicianus), lynx (Lynx canadensis), and black-footed ferrets (Mustela nigripes). Comparison of cassette results for anti-F1 and anti-V antibodies with results of ELISA or HA tests showed correlations ranging from 0.68 to 0.98. This device provides an affordable, user-friendly tool that may be useful in plague surveillance programs and as a research tool.

  17. High frequency of inadequate test requests for antiphospholipid antibodies in daily clinical practice.

    Science.gov (United States)

    Mameli, Antonella; Barcellona, Doris; Vannini, Maria Luigia; Marongiu, Francesco

    2011-04-01

    We have empirically noted that many physicians routinely request anti-phospholipid antibodies (aPL) without a correct clinical indication. The aim of this study was to evaluate retrospectively whether aPL testing at our Thrombosis Centre was justified. Medical records from 520 subjects for aPL screening tests for various clinical conditions were reviewed. The aPL screening tests were: lupus anticoagulant (LA), anti-cardiolipin antibodies (aCL) and anti-β(2) glycoptotein I (aβ(2) GPI). Requests for aPL screening were divided into justified, potentially justified or not adequately justified. aPL testing requests were considered justified in 358 (69%) patients, potentially justified in 66 (12.6%) and not adequately justified in 96 (18.4%). LA was positive in 65 (18%) of justified requests and in only one (1%) of the 96 potentially justified requests. None of the 66 not adequately justified for aPL testing was positive for LA. aβ(2) GPI was positive in 63 (17.6%) of the 358 justified, in four (6%) of the 66 potentially justified and in five (5.2%) of the 96 not adequately justified requests; aCL IgG were positive in 59 (16.4%) of the 358 justified and in five (7.5%) and six (6.2%) of the potentially justified and not adequately justified requests, respectively. The presence of the triple aPL positivity was found exclusively in the justified requests. This study suggests that requests for aPL tests should be addressed more adequately. This work could be an example of how to focus attention on requests for laboratory tests especially on the basis of valid clinical criteria before the analyte is measured.

  18. The meningococcal antibody test: how useful in the diagnosis of meningococcal disease?

    DEFF Research Database (Denmark)

    Weis, N; Berthelsen, L; Wachmann, H

    2005-01-01

    Based on 9257 [correction] blood samples received from 7365 patients with a request for a meningococcal antibody test (MAT) during a 10-year period (1986-1995), the usefulness of the test in the diagnosis of meningococcal disease was assessed. Of 635 patients with culture-confirmed meningococcal...... (29%) had been notified as cases of meningococcal disease. Among 228 patients notified as serologically confirmed the MAT results were consistent with the clinical diagnosis in 86%. MAT is a reliable tool for establishing a diagnosis in patients with suspected meningococcal disease. Key factors...... facilitating appropriate interpretation of negative as well as positive test results were: time(s) of sampling(s) after onset of disease, age of the patient and clinical features....

  19. RBC Antibody Screen

    Science.gov (United States)

    ... products and services. Advertising & Sponsorship: Policy | Opportunities RBC Antibody Screen Share this page: Was this page helpful? ... Indirect Coombs Test; Indirect Anti-human Globulin Test; Antibody Screen Formal name: Red Blood Cell Antibody Screen ...

  20. Rapid Runway Repair (RRR) In-House Test and Evaluation

    Science.gov (United States)

    1988-03-01

    benzoyl peroxide ( BPO ) catalyst, sandbags of crushed stone to extend the Silikal 100 percent, and 5-gallon cans of liquid hardener. Tools in each truck...in that R17/AF has premixed benzoyl peroxide catalyst ( BPO ) and grey powder while R7/AF has separately packaged BPO and grey powder. During the tests...place, but does not meet the "A" quality and cannot be used in place of an "A" level repair. o Repair Upheaval: Repair surface that is above the

  1. Rapid monitoring of recombinant antibody production by mammalian cell cultures using fourier transform infrared spectroscopy and chemometrics.

    Science.gov (United States)

    Sellick, Christopher A; Hansen, Rasmus; Jarvis, Roger M; Maqsood, Arfa R; Stephens, Gill M; Dickson, Alan J; Goodacre, Royston

    2010-06-15

    Fourier transform infrared (FT-IR) spectroscopy combined with multivariate statistical analyses was investigated as a physicochemical tool for monitoring secreted recombinant antibody production in cultures of Chinese hamster ovary (CHO) and murine myeloma non-secreting 0 (NS0) cell lines. Medium samples were taken during culture of CHO and NS0 cells lines, which included both antibody-producing and non-producing cell lines, and analyzed by FT-IR spectroscopy. Principal components analysis (PCA) alone, and combined with discriminant function analysis (PC-DFA), were applied to normalized FT-IR spectroscopy datasets and showed a linear trend with respect to recombinant protein production. Loadings plots of the most significant spectral components showed a decrease in the C-O stretch from polysaccharides and an increase in the amide I band during culture, respectively, indicating a decrease in sugar concentration and an increase in protein concentration in the medium. Partial least squares regression (PLSR) analysis was used to predict antibody titers, and these regression models were able to predict antibody titers accurately with low error when compared to ELISA data. PLSR was also able to predict glucose and lactate amounts in the medium samples accurately. This work demonstrates that FT-IR spectroscopy has great potential as a tool for monitoring cell cultures for recombinant protein production and offers a starting point for the application of spectroscopic techniques for the on-line measurement of antibody production in industrial scale bioreactors. 2010 Wiley Periodicals, Inc.

  2. Problems with rapid agglutination methods for identification of Staphylococcus aureus when Staphylococcus saprophyticus is being tested.

    OpenAIRE

    Gregson, D B; Low, D E; Skulnick, M; Simor, A E

    1988-01-01

    Six rapid agglutination tests for identification of Staphylococcus aureus were evaluated by using 62 strains of S. aureus, 63 strains of S. saprophyticus, and 67 strains of other coagulase-negative staphylococci. S. saprophyticus was responsible for 19 of 26 false-positive results and 20 uninterpretable reactions. Thus, urinary staphylococcal isolates that are positive by rapid agglutination tests may require other confirmatory tests for the identification of possible S. saprophyticus.

  3. A Protein-Conjugate Approach to Develop a Monoclonal Antibody-Based Antigen Detection Test for the Diagnosis of Human Brucellosis

    Science.gov (United States)

    Patra, Kailash P.; Saito, Mayuko; Atluri, Vidya L.; Rolán, Hortensia G.; Young, Briana; Kerrinnes, Tobias; Smits, Henk; Ricaldi, Jessica N.; Gotuzzo, Eduardo; Gilman, Robert H.; Tsolis, Renee M.; Vinetz, Joseph M.

    2014-01-01

    Human brucellosis is most commonly diagnosed by serology based on agglutination of fixed Brucella abortus as antigen. Nucleic acid amplification techniques have not proven capable of reproducibly and sensitively demonstrating the presence of Brucella DNA in clinical specimens. We sought to optimize a monoclonal antibody-based assay to detect Brucella melitensis lipopolysaccharide in blood by conjugating B. melitensis LPS to keyhole limpet hemocyanin, an immunogenic protein carrier to maximize IgG affinity of monoclonal antibodies. A panel of specific of monoclonal antibodies was obtained that recognized both B. melitensis and B. abortus lipopolysaccharide epitopes. An antigen capture assay was developed that detected B. melitensis in the blood of experimentally infected mice and, in a pilot study, in naturally infected Peruvian subjects. As a proof of principle, a majority (7/10) of the patients with positive blood cultures had B. melitensis lipopolysaccharide detected in the initial blood specimen obtained. One of 10 patients with relapsed brucellosis and negative blood culture had a positive serum antigen test. No seronegative/blood culture negative patients had a positive serum antigen test. Analysis of the pair of monoclonal antibodies (2D1, 2E8) used in the capture ELISA for potential cross-reactivity in the detection of lipopolysaccharides of E. coli O157:H7 and Yersinia enterocolitica O9 showed specificity for Brucella lipopolysaccharide. This new approach to develop antigen-detection monoclonal antibodies against a T cell-independent polysaccharide antigen based on immunogenic protein conjugation may lead to the production of improved rapid point-of-care-deployable assays for the diagnosis of brucellosis and other infectious diseases. PMID:24901521

  4. 9 CFR 147.3 - The stained-antigen, rapid, whole-blood test. 3

    Science.gov (United States)

    2010-01-01

    ...-blood test. 3 147.3 Section 147.3 Animals and Animal Products ANIMAL AND PLANT HEALTH INSPECTION SERVICE... Blood Testing Procedures § 147.3 The stained-antigen, rapid, whole-blood test. 3 3 The procedure... necessary. The test plate should be rocked from side to side a few times to mix the antigen and blood...

  5. evaluation of a rapid test for hiv antibodies in saliva and blood

    African Journals Online (AJOL)

    The implications of this epidemic include the rising costs and logistics associated with laboratory analysis of traditional diagnostic methods for diagnOSing HIV, which often involve the taking, handling, transport and storage of invasively obtained specimens as well as the availability of equipment, electricity and refrigeration.

  6. evaluation of a rapid test for hiv antibodies in saliva and blood

    African Journals Online (AJOL)

    costs and logistics associated with laboratory analysis of ... hospital setting. Twenty-three HIV-negative specimens were selected from individuals in the community and 23 from hospital patients. Forty-one postmortem specimens were ..... Presented at the XI International Conference on AIDS, Vancouver, British Colombia;.

  7. Rapid high temperature field test method for evaluation of geothermal calcite scale inhibitors

    Energy Technology Data Exchange (ETDEWEB)

    Asperger, R.G.

    1982-08-01

    A test method is described which allows the rapid field testing of calcite scale inhibitors in high- temperature geothermal brines. Five commercial formulations, chosen on the basis of laboratory screening tests, were tested in brines with low total dissolved solids at ca 500 F. Four were found to be effective; of these, 2 were found to be capable of removing recently deposited scale. One chemical was tested in the full-flow brine line for 6 wks. It was shown to stop a severe surface scaling problem at the well's control valve, thus proving the viability of the rapid test method. (12 refs.)

  8. Acute HIV Discovered During Routine HIV Screening With HIV Antigen-Antibody Combination Tests in 9 US Emergency Departments.

    Science.gov (United States)

    White, Douglas A E; Giordano, Thomas P; Pasalar, Siavash; Jacobson, Kathleen R; Glick, Nancy R; Sha, Beverly E; Mammen, Priya E; Hunt, Bijou R; Todorovic, Tamara; Moreno-Walton, Lisa; Adomolga, Vincent; Feaster, Daniel J; Branson, Bernard M

    2018-01-05

    Newer combination HIV antigen-antibody tests allow detection of HIV sooner after infection than previous antibody-only immunoassays because, in addition to HIV-1 and -2 antibodies, they detect the HIV-1 p24 antigen, which appears before antibodies develop. We determine the yield of screening with HIV antigen-antibody tests and clinical presentations for new diagnoses of acute and established HIV infection across US emergency departments (EDs). This was a retrospective study of 9 EDs in 6 cities with HIV screening programs that integrated laboratory-based antigen-antibody tests between November 1, 2012, and December 31, 2015. Unique patients with newly diagnosed HIV infection were identified and classified as having either acute HIV infection or established HIV infection. Acute HIV infection was defined as a repeatedly reactive antigen-antibody test result, a negative HIV-1/HIV-2 antibody differentiation assay, or Western blot result, but detectable HIV ribonucleic acid (RNA); established HIV infection was defined as a repeatedly reactive antigen-antibody test result and a positive HIV-1/HIV-2 antibody differentiation assay or Western blot result. The primary outcomes were the number of new HIV diagnoses and proportion of patients with laboratory-defined acute HIV infection. Secondary outcomes compared reason for visit and the clinical presentation of acute HIV infection. In total, 214,524 patients were screened for HIV and 839 (0.4%) received a new diagnosis, of which 122 (14.5%) were acute HIV infection and 717 (85.5%) were established HIV infection. Compared with patients with established HIV infection, those with acute HIV infection were younger, had higher RNA and CD4 counts, and were more likely to have viral syndrome (41.8% versus 6.5%) or fever (14.3% versus 3.4%) as their reason for visit. Most patients with acute HIV infection displayed symptoms attributable to acute infection (median symptom count 5 [interquartile range 3 to 6]), with fever often

  9. Small Projects Rapid Integration and Test Environment (SPRITE): Application for Increasing Robustness

    Science.gov (United States)

    Rakoczy, John; Heater, Daniel; Lee, Ashley

    2013-01-01

    Marshall Space Flight Center's (MSFC) Small Projects Rapid Integration and Test Environment (SPRITE) is a Hardware-In-The-Loop (HWIL) facility that provides rapid development, integration, and testing capabilities for small projects (CubeSats, payloads, spacecraft, and launch vehicles). This facility environment focuses on efficient processes and modular design to support rapid prototyping, integration, testing and verification of small projects at an affordable cost, especially compared to larger type HWIL facilities. SPRITE (Figure 1) consists of a "core" capability or "plant" simulation platform utilizing a graphical programming environment capable of being rapidly re-configured for any potential test article's space environments, as well as a standard set of interfaces (i.e. Mil-Std 1553, Serial, Analog, Digital, etc.). SPRITE also allows this level of interface testing of components and subsystems very early in a program, thereby reducing program risk.

  10. In silico design and performance of peptide microarrays for breast cancer tumour-auto-antibody testing

    Directory of Open Access Journals (Sweden)

    Andreas Weinhäusel

    2012-06-01

    Full Text Available The simplicity and potential of minimally invasive testing using sera from patients makes auto-antibody based biomarkers a very promising tool for use in cancer diagnostics. Protein microarrays have been used for the identification of such auto-antibody signatures. Because high throughput protein expression and purification is laborious, synthetic peptides might be a good alternative for microarray generation and multiplexed analyses. In this study, we designed 1185 antigenic peptides, deduced from proteins expressed by 642 cDNA expression clones found to be sero-reactive in both breast tumour patients and controls. The sero-reactive proteins and the corresponding peptides were used for the production of protein and peptide microarrays. Serum samples from females with benign and malignant breast tumours and healthy control sera (n=16 per group were then analysed. Correct classification of the serum samples on peptide microarrays were 78% for discrimination of ‘malignant versus healthy controls’, 72% for ‘benign versus malignant’ and 94% for ‘benign versus controls’. On protein arrays, correct classification for these contrasts was 69%, 59% and 59%, respectively. The over-representation analysis of the classifiers derived from class prediction showed enrichment of genes associated with ribosomes, spliceosomes, endocytosis and the pentose phosphate pathway. Sequence analyses of the peptides with the highest sero-reactivity demonstrated enrichment of the zinc-finger domain. Peptides’ sero-reactivities were found negatively correlated with hydrophobicity and positively correlated with positive charge, high inter-residue protein contact energies and a secondary structure propensity bias. This study hints at the possibility of using in silico designed antigenic peptide microarrays as an alternative to protein microarrays for the improvement of tumour auto-antibody based diagnostics.

  11. Comparison of a serum indirect fluorescent antibody test with two Western blot tests for the diagnosis of equine protozoal myeloencephalitis.

    Science.gov (United States)

    Duarte, Paulo C; Daft, Barbara M; Conrad, Patricia A; Packham, Andrea E; Gardner, Ian A

    2003-01-01

    A serum indirect fluorescent antibody test (IFAT) was compared with a Western blot (WB) and a modified Western blot (mWB) for diagnosis of equine protozoal myeloencephalitis (EPM). Using receiver-operating characteristic (ROC) analysis, the area under the curve of the IFAT was greater than the areaunder the curves of the WB and the mWB (P = 0.025 and P = 0.044, respectively). There was no statistically significant difference between the areas under the curves of the WBs (P > 0.05). On the basis of an arbitrarily chosen cut-off titer for a positive test result of 1:80 for the IFAT and interpreting weak positive WB results as positive test results, the sensitivities and 95% confidence intervals (CI) of all 3 tests were identical and equal to 88.9% (51.8-99.7%). The specificities and 95% CIs of the IFAT, WB, and mWB test were 100% (91-100%), 87.2% (72.6-95.7%), and 69.2% (52.4-83%), respectively. The overall accuracy of the IFAT was shown to be better than that of the WBs and, therefore, the test has potential for use in the diagnosis of EPM caused by Sarcocystis neurona.

  12. Hepatitis B core antibody testing in Indian blood donors: A double-edged sword!

    Directory of Open Access Journals (Sweden)

    R N Makroo

    2012-01-01

    Full Text Available Background: Until lately, anti-HBc antibodies were considered an effective marker for occult Hepatitis B virus (HBV infection and have served their role in improving blood safety. But, with the development of advanced tests for HBV DNA detection, the role of anti-HBc in this regard stands uncertain. Materials and Methods: Anti-HBc and HBsAg ELISA and ID-NAT tests were run in parallel on donor blood samples between April 1, 2006 and December 31, 2010 at the Department of Transfusion Medicine, Indraprastha Apollo Hospitals, New Delhi. A positive ID-NAT was followed by Discriminatory NAT assay. Results: A total of 94 247 samples were tested with a total core positivity rate of 10.22%. We identified nearly 9.17% of donors who were reactive for anti-HBc and negative for HBsAg and HBV DNA. These are the donors who are potentially non-infectious and may be returned to the donor pool. Conclusion: Although anti HBc testing has a definite role in improving blood safety, centers that have incorporated NAT testing may not derive any additional benefit by performing anti-HBc testing, especially in resource-limited countries like ours.

  13. A Pilot Study of Rapid Hepatitis C Testing in Probation and Parole Populations in Rhode Island.

    Science.gov (United States)

    Zaller, Nickolas D; Patry, Emily J; Bazerman, Lauri B; Noska, Amanda; Kuo, Irene; Kurth, Ann; Beckwith, Curt G

    2016-01-01

    Hepatitis C virus (HCV) affects between five and seven million individuals in the United States and chronic infection can lead to liver disease, cirrhosis, and hepatocellular carcinoma. Probation/parole offices are a novel setting for rapid HCV testing, providing outreach to populations at increased risk for HCV infection and/or transmitting HCV to others. While some correctional facilities offer HCV testing, many individuals who present to probation/parole offices are never or briefly incarcerated and may not access medical services. We conducted a rapid HCV testing pilot at probation/parole offices in Rhode Island. Overall, 130 people accepted rapid HCV testing, of whom 12 had reactive tests. Only four of these individuals presented to a community-based clinic for confirmatory testing, despite being offered a monetary incentive. Identifying and addressing barriers to HCV confirmatory testing and follow-up care is critical to increasing the uptake of HCV care and treatment in this vulnerable population.

  14. Rapid Immunochromatographic Detection of Serum Anti-α-Galactosidase A Antibodies in Fabry Patients after Enzyme Replacement Therapy.

    Directory of Open Access Journals (Sweden)

    Sachie Nakano

    Full Text Available We developed an immunochromatography-based assay for detecting antibodies against recombinant α-galactosidase A proteins in serum. The evaluation of 29 serum samples from Fabry patients, who had received enzyme replacement therapy with agalsidase alpha and/or agalsidase beta, was performed by means of this assay method, and the results clearly revealed that the patients exhibited the same level of antibodies against both agalsidase alpha and agalsidase beta, regardless of the species of recombinant α-galactosidase A used for enzyme replacement therapy. A conventional enzyme-linked immunosorbent assay supported the results. Considering these, enzyme replacement therapy with agalsidase alpha or agalsidase beta would generate antibodies against the common epitopes in both agalsidase alpha and agalsidase beta. Most of the patients who showed immunopositive reaction exhibited classic Fabry phenotype and harbored gene mutations affecting biosynthesis of α-galactosidase A. As immunochromatography is a handy and simple assay system which can be available at bedside, this assay method would be extremely useful for quick evaluation or first screening of serum antibodies against agalsidase alpha or agalsidase beta in Fabry disease with enzyme replacement therapy.

  15. [A case of rapid-onset antimitochondrial antibody-positive autoimmune hepatitis possibly triggered by a urinary tract infection].

    Science.gov (United States)

    Kiriyama, Kazuo; Usui, Takeo; Takemura, Tadaharu; Ikeda, Koichiro; Kishida, Hiroshi; Izumoto, Takayuki; Kanayama, Yoshio; Hirota, Seiichi

    2010-02-01

    A 54-year-old woman suffered acute hepatitis after she acquired cystitis. Laboratory results on admission showed: AST 925, ALT 1171, ALP 623, gamma-GTP127 IU/l, T-Bil 5.0 mg/dl, antinuclear antibodies negative, smooth muscle antibodies 80, antimitochondrial antibodies (AMA) 80, antimitochondrial M2 antibody (AMA-M2) 117 index, IgG 2210 mg/dl. She also had HLA-DR4 and HLA-DR8. Histological study of a liver biopsy specimen suggested that she had autoimmune hepatitis rather than primary biliary cirrhosis. When prednisolone was administered, her liver function immediately improved and AMA and AMA-M2 levels fell to 20 and 52 respectively. However when cystitis recurred 4 months later, her liver function worsened. Laboratory findings showed AST 174, ALT 183 IU/l. Upon increasing the dosage of prednisolone, her liver function improved again. After the recurrence of hepatitis, AMA and AMA-M2 levels increased to 320 and 149 respectively. We speculate that the urinary tract infection triggered an autoimmune response and her genetic predisposition also played a crucial role in the process.

  16. Qualification Testing Versus Quantitative Reliability Testing of PV - Gaining Confidence in a Rapidly Changing Technology: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Kurtz, Sarah [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Repins, Ingrid L [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Hacke, Peter L [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Jordan, Dirk [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Kempe, Michael D [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Whitfield, Kent [Underwriters Laboratories; Phillips, Nancy [DuPont; Sample, Tony [European Commission; Monokroussos, Christos [TUV Rheinland; Hsi, Edward [Swiss RE; Wohlgemuth, John [PowerMark Corporation; Seidel, Peter [First Solar; Jahn, Ulrike [TUV Rheinland; Tanahashi, Tadanori [National Institute of Advanced Industrial Science and Technology; Chen, Yingnan [China General Certification Center; Jaeckel, Bengt [Underwriters Laboratories; Yamamichi, Masaaki [RTS Corporation

    2017-10-05

    Continued growth of PV system deployment would be enhanced by quantitative, low-uncertainty predictions of the degradation and failure rates of PV modules and systems. The intended product lifetime (decades) far exceeds the product development cycle (months), limiting our ability to reduce the uncertainty of the predictions for this rapidly changing technology. Yet, business decisions (setting insurance rates, analyzing return on investment, etc.) require quantitative risk assessment. Moving toward more quantitative assessments requires consideration of many factors, including the intended application, consequence of a possible failure, variability in the manufacturing, installation, and operation, as well as uncertainty in the measured acceleration factors, which provide the basis for predictions based on accelerated tests. As the industry matures, it is useful to periodically assess the overall strategy for standards development and prioritization of research to provide a technical basis both for the standards and the analysis related to the application of those. To this end, this paper suggests a tiered approach to creating risk assessments. Recent and planned potential improvements in international standards are also summarized.

  17. Are participants in a street-based HIV testing program able to perform their own rapid test and interpret the results?

    Directory of Open Access Journals (Sweden)

    Luis de la Fuente

    Full Text Available OBJECTIVE: Availability of over-the-counter rapid HIV tests could improve access to testing those reluctant or unable to use current services. We aimed to evaluate the feasibility of HIV self-testing using a finger-stick whole-blood rapid test (Determine™ HIV Combo to detect both antigen and antibody. METHODS: Before being tested, 313 participants in a street-based testing program were given adapted instructions and a test kit, and performed the self-test without supervision. These participants, together with another 207 who performed supervised self-testing, received additional instructions on how to interpret the test results shown in six colour photos and filled out a questionnaire. Logistic regression and generalized estimating equations (GEE were used in the statistical analysis. RESULTS: About 8.0% (95%CI:4.8%-11.2% obtained an invalid self-test. An invalid result was inversely associated with male participants who had sex with men (OR=0.3;95%CI:0.1-1.0. Of the 3111 photos interpreted,4.9% (95%CI:4.1-5.7 were incorrect. Only 1.1% (95%CI:0.3-1.8 of the positive results were interpreted as negative. Age 30 or older (OR=2.1; 95%CI:1.2-3.7, having been born in Latin America (OR=1.6; 95%CI:1.1-2.2,and not having university education (OR=2.1;95%CI:1.2-3.7 were associated with misinterpreting test results in the GEE. Participant's perceptions of both their proficiency when conducting the test and interpretation were related with actual outcomes. Most participants (83.9% were more motivated than before to use the self-test in the future, and 51.7% would pay >10 Euros for the test if it was sold in pharmacies. CONCLUSIONS: This is the first study showing that blood-based self-testing with current technology is feasible in HIV-negative participants demanding the test and without prior training or supervision. Bearing in mind that it was conducted under difficult weather conditions and using a complex kit, over-the-counter tests could be a feasible

  18. Are participants in a street-based HIV testing program able to perform their own rapid test and interpret the results?

    Science.gov (United States)

    de la Fuente, Luis; Rosales-Statkus, María Elena; Hoyos, Juan; Pulido, José; Santos, Sara; Bravo, María José; Barrio, Gregorio; Fernández-Balbuena, Sonia; Belza, María José

    2012-01-01

    Availability of over-the-counter rapid HIV tests could improve access to testing those reluctant or unable to use current services. We aimed to evaluate the feasibility of HIV self-testing using a finger-stick whole-blood rapid test (Determine™ HIV Combo) to detect both antigen and antibody. Before being tested, 313 participants in a street-based testing program were given adapted instructions and a test kit, and performed the self-test without supervision. These participants, together with another 207 who performed supervised self-testing, received additional instructions on how to interpret the test results shown in six colour photos and filled out a questionnaire. Logistic regression and generalized estimating equations (GEE) were used in the statistical analysis. About 8.0% (95%CI:4.8%-11.2%) obtained an invalid self-test. An invalid result was inversely associated with male participants who had sex with men (OR=0.3;95%CI:0.1-1.0). Of the 3111 photos interpreted,4.9% (95%CI:4.1-5.7) were incorrect. Only 1.1% (95%CI:0.3-1.8) of the positive results were interpreted as negative. Age 30 or older (OR=2.1; 95%CI:1.2-3.7), having been born in Latin America (OR=1.6; 95%CI:1.1-2.2),and not having university education (OR=2.1;95%CI:1.2-3.7) were associated with misinterpreting test results in the GEE. Participant's perceptions of both their proficiency when conducting the test and interpretation were related with actual outcomes. Most participants (83.9%) were more motivated than before to use the self-test in the future, and 51.7% would pay >10 Euros for the test if it was sold in pharmacies. This is the first study showing that blood-based self-testing with current technology is feasible in HIV-negative participants demanding the test and without prior training or supervision. Bearing in mind that it was conducted under difficult weather conditions and using a complex kit, over-the-counter tests could be a feasible option to complement current diagnostic strategies

  19. False positive malaria rapid diagnostic test in returning traveler with typhoid fever.

    Science.gov (United States)

    Meatherall, Bonnie; Preston, Keith; Pillai, Dylan R

    2014-07-09

    Rapid diagnostic tests play a pivotal role in the early diagnosis of malaria where microscopy or polymerase chain reaction are not immediately available. We report the case of a 39 year old traveler to Canada who presented with fever, headache, and abdominal pain after visiting friends and relatives in India. While in India, the individual was not ill and had no signs or symptoms of malaria. Laboratory testing upon his return to Canada identified a false positive malaria rapid diagnostic (BinaxNOW® malaria) result for P. falciparum with coincident Salmonella Typhi bacteraemia without rheumatoid or autoimmune factors. Rapid diagnostic test false positivity for malaria coincided with the presence or absence of Salmonella Typhi in the blood. Clinicians should be aware that Salmonella Typhi infection may result in a false positive malaria rapid diagnostic test. The mechanism of this cross-reactivity is not clear.

  20. Performance of rapid HIV testing using Determine HIV-1/2 for the diagnosis of HIV infection during pregnancy in Tijuana, Baja California, Mexico.

    Science.gov (United States)

    Viani, R M; Hubbard, P; Ruiz-Calderon, J; Araneta, M R G; Lopez, G; Chacón-Cruz, E; Spector, S A

    2007-02-01

    The aim of this study was to evaluate the performance of the rapid antibody test Determine HIV-1/2, in pregnant women at Tijuana General Hospital. Pregnant women seeking prenatal care or admitted in labour had blood drawn for a rapid HIV test (Determine HIV-1/2), enzyme immunoassay (EIA) and Western blot. Between March and November 2003, 1068 women in labour and 1529 women in prenatal care were enrolled. The sensitivity, specificity, positive and negative predictive values were 100%, 99.8%, 77% and 100%, respectively. For women in labour, the mean time between blood collection and rapid test results was 92 minutes (range: 20-205 minutes) compared with 41 hours (range 24-120 hours) for HIV EIA (P = 0.012). All HIV-exposed infants received oral zidovudine. These findings indicate that the rapid test Determine HIV-1/2 has a high sensitivity and specificity in pregnant women. Rapid HIV testing greatly diminishes the time to diagnosis and enables prompt intervention with antiretrovirals at delivery.

  1. Assessment of the validity of rapid diagnostic test kits available in ...

    African Journals Online (AJOL)

    Blood samples were collected for serology tests using five (5) different rapid diagnostic test kits from different manufacturers, HIV status determination and evaluation of the haematological parameters we carried out. As a result, there were significant differences in the results obtained between AFB tests and serological ...

  2. Rapid Point-of-Care Diagnostic Test for Syphilis in High-Risk Populations, Manaus, Brazil

    Science.gov (United States)

    Benzaken, Adele S.; de Andrade Rodrigues, Ệnio José; Mayaud, Philippe

    2009-01-01

    We assessed the acceptability and operational suitability of a rapid point-of-care syphilis test and identified barriers to testing among high-risk groups and healthcare professionals in a sexually transmitted infections clinic in Manaus, Brazil. Use of this test could considerably alleviate the impact of syphilis in hard-to-reach populations in the Amazon region of Brazil. PMID:19331762

  3. Direct, rapid antimicrobial susceptibility test from positive blood cultures based on microscopic imaging analysis

    OpenAIRE

    Choi, Jungil; Jeong, Hyun Yong; Lee, Gi Yoon; Han, Sangkwon; Han, Shinhun; Jin, Bonghwan; Lim, Taegeun; Kim, Shin; Kim, Dong Young; Kim, Hee Chan; Kim, Eui-Chong; Song, Sang Hoon; Kim, Taek Soo; Kwon, Sunghoon

    2017-01-01

    For the timely treatment of patients with infections in bloodstream and cerebrospinal fluid, a rapid antimicrobial susceptibility test (AST) is urgently needed. Here, we describe a direct and rapid antimicrobial susceptibility testing (dRAST) system, which can determine the antimicrobial susceptibility of bacteria from a positive blood culture bottle (PBCB) in six hours. The positive blood culture sample is directly mixed with agarose and inoculated into a micropatterned plastic microchip wit...

  4. Comparison of different commercial serological tests for the detection of Toxoplasma gondii antibodies in serum of naturally exposed pigs.

    Science.gov (United States)

    Steinparzer, R; Reisp, K; Grünberger, B; Köfer, J; Schmoll, F; Sattler, T

    2015-03-01

    Toxoplasma gondii is the aetiological agent of the zoonotic disease toxoplasmosis and transmitted among other ways by chemically and physically untreated, that is, raw pork to humans. The detection of Toxoplasma gondii is impossible by currently practiced meat inspection, but serological tests can be used to detect Toxoplasma gondii antibodies in pig herds and can consequently be helpful to identify potentially contaminated pork. Therefore, appropriate serological tests are required. In this study, serum samples of 1368 naturally exposed slaughter pigs from 73 Austrian farms were collected. Serum samples of at least 16 slaughter pigs per farm were tested. The prevalence of Toxoplasma gondii antibodies in serum was measured by a commercial available modified agglutination test (MAT) and compared to three different commercial available enzyme-linked immunosorbent assays (ELISA). The MAT detected 6.5%, ELISA I 6.7%, ELISA II 4.8% and ELISA III 4.3% of the pigs as Toxoplasma gondii antibody positive. The agreement, according to the kappa coefficient (κ), was substantial between the MAT and ELISA I (κ = 0.62), II (κ = 0.64) and III (κ = 0.67). A better agreement was determined between ELISA I and II (κ = 0.715), ELISA I and III (κ = 0.747) and ELISA II and III (κ = 0.865). At least one pig per farm was detected Toxoplasma gondii antibody positive in 17 (23.3%) farms by the MAT, 26 (35.6%) farms by ELISA I, 16 (21.9%) farms by ELISA II and 11 (15.1%) farms by ELISA III. Pig farms with a high number of Toxoplasma gondii antibody-positive pigs or high antibody titres were identified by all of the four used serological tests. Concerning the occurrence of Toxoplasma gondii antibodies in Austrian pig farms, a monitoring and surveillance programme would be reasonable to find high-risk farms. © 2014 Blackwell Verlag GmbH.

  5. Multiplex viral polymerase chain reaction testing using the FilmArray device compared with direct fluorescent antibody testing.

    Science.gov (United States)

    Wang, Jason; Simons, Debra B; Adams, James L; Jerris, Robert C; Rogers, Beverly Barton

    2014-01-01

    Advances in fluidics, electronics, and instrument design have enabled automation of complex molecular assays. The FilmArray Respiratory Panel (RP) is one such assay; it allows for rapid detection of multiple viral and bacterial respiratory targets via nested polymerase chain reaction (PCR), with all components contained within a single pouch. We performed a detailed comparison of workflow between the FilmArray RP and direct fluorescent antibody (DFA) staining. The FilmArray RP proved to be more efficient, with as few as 91 total touches needed and as little as 4 minutes 52 seconds hands-on time. This compares with as many as 502 total touches and 12 minutes 45 seconds hands-on time for DFA staining. FilmArray RP detected a greater number of organisms (20 viruses and bacteria vs 7 viruses for DFA staining) and required less training compared with DFA staining. The ease of use of the FilmArray RP makes this molecular assay amenable to operation 24 hours a day, 7 days a week in routine laboratory and point-of-care settings.

  6. An Evaluation of Introduction of Rapid HIV Testing in a Perinatal Program.

    Science.gov (United States)

    Saunders, Sarah; Tulloch, Karen; Maan, Evelyn J; van Schalkwyk, Julianne; Money, Deborah M

    2017-08-01

    This study was conducted to evaluate the roll-out of rapid HIV testing as part of an emergency Prevention of Perinatal HIV Transmission Program. Specifically, HIV prevalence in this population, the reason(s) for performing the rapid HIV test, and compliance with recommendations for antiretroviral prophylaxis were assessed. Since November 2011, all women presenting to a tertiary labour and delivery unit with unknown HIV status or with ongoing risk of HIV infection since their last HIV test were offered rapid HIV testing. Through retrospective chart review, demographic data, HIV risk and prior testing history, and antiretroviral prophylaxis, data were collected and descriptive statistics were performed. One hundred fourteen rapid HIV tests were conducted and there were two preliminary reactive rapid results (one true positive, one false positive). None of the infants was HIV infected. Sixty-three percent of women had multiple risk factors for HIV acquisition, most commonly intravenous drug use (54%). Forty-four percent of women were within the 4-week seroconversion window at the time of delivery; 25% of these women and 52% of their infants received prophylactic drug therapy. Rapid HIV testing identified a high-risk cohort and enabled aggressive management of a newly diagnosed HIV-positive pregnancy, successfully preventing perinatal HIV transmission. Risk factors for HIV acquisition were ongoing within the seroconversion window for over half of the women, impacting the utility of the test in eliminating unnecessary antiretroviral prophylaxis in this population because prophylaxis is recommended despite a negative rapid HIV test in these cases. Copyright © 2017 The Society of Obstetricians and Gynaecologists of Canada/La Société des obstétriciens et gynécologues du Canada. Published by Elsevier Inc. All rights reserved.

  7. Diagnostic Value of ELISA Tests for the Detection of Specific Antibodies in Cats and Rabbits with Dermatophytosis

    Directory of Open Access Journals (Sweden)

    Marinka Drobnič-Košorok

    2002-01-01

    Full Text Available Two indirect ELISA tests developed for the detection of specific IgG in cats and rabbits, infected with M. canis and T. mentagrophytes, respectively, were evaluated and compared. The levels of specific antibodies were determined in sera of 20 cats and 25 rabbits naturally infected with M. canis and T. mentagrophytes, respectively. Infection was confirmed by the results of fungal culture. Blood samples from 12 cats and 17 rabbits, previously unexposed to dermatophytes, served as negative controls. A significant increase in the level of specific antibodies in groups of infected animals was demonstrated. Sensitivity, specificity and predictive values of a positive and a negative test were determined to evaluate the diagnostic potential. ELISA for the detection of specific antibodies in cats infected with M. canis (ELISA-cats test exhibited 75.0 % of sensitivity at 91.7 % of specificity, whereas the test for the detection of specific antibodies in rabbits, infected with T. mentagrophytes (ELISA-rabbits test is highly sensitive (96.0 % and highly specific (94.1 %, confirming its encouraging diagnostic potential. The cross-reactivity of fungal antigens was tested by performing the assays with antigens M. canis, T. mentagrophytes, M. pachydermatis and A. fumigatus. There were no significant indications of cross-reactions in the test T. mentagrophytes-rabbits, whereas strong cross-reaction between dermatophyte antigens was observed in the test M. canis-cats.

  8. [Evaluation of Mascia Brunelli rapid antigen test in the diagnosis of group A streptococcal pharyngitis].

    Science.gov (United States)

    Barış, Ayşe; Anlıaçık, Nur; Bulut, Mehmet Emin; Deniz, Rıdvan; Yücel, Elif; Aktaş, Elif

    2017-01-01

    Pharyngitis in most cases is due to viral microorganisms however drug therapy without the detection of etiological agent leads to unnecessary use of antibiotics. On the other hand, when the etiologic agent is group A beta-hemolytic streptococci (GAS) it is important to identify the etiologic agent rapidly which will guide the treatment with appropriate antibiotics. The use of highly sensitive rapid tests will contribute significantly to early diagnosis and appropriate therapy. The aim of this study is to evaluate the efficacy of Mascia Brunelli rapid antigen test for the detection of GAS in throat swab samples. A total of 833 throat swab samples submitted to our laboratory with pre-diagnosis of pharyngitis were assessed between June 2016 and August 2016. The samples were simultaneously cultured and tested by rapid Mascia Brunelli Strep-A Card (Mascia Brunelli S.p.a, Italy). For identification, bacitracin sensitivity, PYR test and latex agglutination test in addition to Bruker MALDI-TOF MS (Daltonics, Germany) system were used. The density of GAS growth in the culture was noted. The samples that were false negative with Mascia Brunelli test were re-tested with QuickVue + Strep A Test (Quidel Corporation, San Diego, USA) rapid antigen test. A total of 833 patients, 376 (45.2%) female and 457 (54.8%) male were included in the study. The age range was between 0-94 years with a mean value of 7.86 ± 6.72. 125 (15%) and 94 (11.28%) of the samples were positive with culture and rapid antigen test, respectively. Mascia Brunelli antigen test gave negative results for 31 culture positive samples. Of these 31 samples, 28 were found positive by QuickVue + Strep A antigen test. As a result, the sensitivity of the test was found to be independent of the inoculum effect. The culture positivity rate in patients between 5-15 years was 18.4%. The sensitivity, specificity, positive predictive value, negative predictive value and the accuracy of Mascia Brunelli antigen test, with

  9. Development and Evaluation of a Pseudovirus-Luciferase Assay for Rapid and Quantitative Detection of Neutralizing Antibodies against Enterovirus 71

    OpenAIRE

    Xing Wu; Qunying Mao; Xin Yao; Pan Chen; Xiangmei Chen; Jie Shao; Fan Gao; Xiang Yu; Fengcai Zhu; Rongcheng Li; Wenhui Li; Zhenglun Liang; Junzhi Wang; Fengmin Lu

    2013-01-01

    The level of neutralizing antibodies (NtAb) induced by vaccine inoculation is an important endpoint to evaluate the efficacy of EV71 vaccine. In order to evaluate the efficacy of EV71 vaccine, here, we reported the development of a novel pseudovirus system expression firefly luciferase (PVLA) for the quantitative measurement of NtAb. We first evaluated and validated the sensitivity and specificity of the PVLA method. A total of 326 serum samples from an epidemiological survey and 144 serum sp...

  10. Rapid transient production in plants by replicating and non-replicating vectors yields high quality functional anti-HIV antibody.

    Science.gov (United States)

    Sainsbury, Frank; Sack, Markus; Stadlmann, Johannes; Quendler, Heribert; Fischer, Rainer; Lomonossoff, George P

    2010-11-12

    The capacity of plants and plant cells to produce large amounts of recombinant protein has been well established. Due to advantages in terms of speed and yield, attention has recently turned towards the use of transient expression systems, including viral vectors, to produce proteins of pharmaceutical interest in plants. However, the effects of such high level expression from viral vectors and concomitant effects on host cells may affect the quality of the recombinant product. To assess the quality of antibodies transiently expressed to high levels in plants, we have expressed and characterised the human anti-HIV monoclonal antibody, 2G12, using both replicating and non-replicating systems based on deleted versions of Cowpea mosaic virus (CPMV) RNA-2. The highest yield (approximately 100 mg/kg wet weight leaf tissue) of affinity purified 2G12 was obtained when the non-replicating CPMV-HT system was used and the antibody was retained in the endoplasmic reticulum (ER). Glycan analysis by mass-spectrometry showed that the glycosylation pattern was determined exclusively by whether the antibody was retained in the ER and did not depend on whether a replicating or non-replicating system was used. Characterisation of the binding and neutralisation properties of all the purified 2G12 variants from plants showed that these were generally similar to those of the Chinese hamster ovary (CHO) cell-produced 2G12. Overall, the results demonstrate that replicating and non-replicating CPMV-based vectors are able to direct the production of a recombinant IgG similar in activity to the CHO-produced control. Thus, a complex recombinant protein was produced with no apparent effect on its biochemical properties using either high-level expression or viral replication. The speed with which a recombinant pharmaceutical with excellent biochemical characteristics can be produced transiently in plants makes CPMV-based expression vectors an attractive option for biopharmaceutical development

  11. Rapid High-Level Production of Functional HIV Broadly Neutralizing Monoclonal Antibodies in Transient Plant Expression Systems

    OpenAIRE

    Yvonne Rosenberg; Markus Sack; David Montefiori; Donald Forthal; Lingjun Mao; Segundo Hernandez-Abanto; Lori Urban; Gary Landucci; Rainer Fischer; Xiaoming Jiang

    2013-01-01

    Passive immunotherapy using anti-HIV broadly neutralizing monoclonal antibodies (mAbs) has shown promise as an HIV treatment, reducing mother-to-child-transmission (MTCT) of simian/human immunodeficiency virus (SHIV) in non-human primates and decreasing viral rebound in patients who ceased receiving anti-viral drugs. In addition, a cocktail of potent mAbs may be useful as mucosal microbicides and provide an effective therapy for post-exposure prophylaxis. However, even highly neutralizing HIV...

  12. Rapid transient production in plants by replicating and non-replicating vectors yields high quality functional anti-HIV antibody.

    Directory of Open Access Journals (Sweden)

    Frank Sainsbury

    2010-11-01

    Full Text Available The capacity of plants and plant cells to produce large amounts of recombinant protein has been well established. Due to advantages in terms of speed and yield, attention has recently turned towards the use of transient expression systems, including viral vectors, to produce proteins of pharmaceutical interest in plants. However, the effects of such high level expression from viral vectors and concomitant effects on host cells may affect the quality of the recombinant product.To assess the quality of antibodies transiently expressed to high levels in plants, we have expressed and characterised the human anti-HIV monoclonal antibody, 2G12, using both replicating and non-replicating systems based on deleted versions of Cowpea mosaic virus (CPMV RNA-2. The highest yield (approximately 100 mg/kg wet weight leaf tissue of affinity purified 2G12 was obtained when the non-replicating CPMV-HT system was used and the antibody was retained in the endoplasmic reticulum (ER. Glycan analysis by mass-spectrometry showed that the glycosylation pattern was determined exclusively by whether the antibody was retained in the ER and did not depend on whether a replicating or non-replicating system was used. Characterisation of the binding and neutralisation properties of all the purified 2G12 variants from plants showed that these were generally similar to those of the Chinese hamster ovary (CHO cell-produced 2G12.Overall, the results demonstrate that replicating and non-replicating CPMV-based vectors are able to direct the production of a recombinant IgG similar in activity to the CHO-produced control. Thus, a complex recombinant protein was produced with no apparent effect on its biochemical properties using either high-level expression or viral replication. The speed with which a recombinant pharmaceutical with excellent biochemical characteristics can be produced transiently in plants makes CPMV-based expression vectors an attractive option for

  13. Standardization of serological tests for detecting anti-Trypanosoma cruzi antibodies in dogs

    Directory of Open Access Journals (Sweden)

    M. A. Lauricella

    1993-09-01

    Full Text Available This paper reports on the standardization of four serological reactions currently used in human serodiagnosis for the detection of anti-Trypanosoma cruzi antibodies in naturally and experimentally infected dogs. Indirect immunofluorescence test (IFAT and hemagglutination test (IHAT were standardized, and complement fixation test (CFT and direct agglutination test (DAT were used for diagnostic confirmation. Four hundred and eighty one mongrel dogs that were studied by xenodiagnosis were used: (1 parasitemic dogs of two localities of endemic area (EA of Santiago del Estero province in Argentina (n = 134; (2 non-parasitemic dogs of the same area (n = 285; (3 dogs experimentally infected with T. cruzi in the patent period (n = 6; (4 non-infected dogs (n = 56 which were born in the city of Buenos Aires (BA, one non-EA for Chagas' disease. For IFAT, parasitemic dogs EA showed 95% of reactive sera. Non parasitemic dogs EA showed 77% of non reactive sera. None sera from BA were reactive for dilutions higher than four. For IHAT, 84% of sera of parasitemic dogs EA showed serological reactivity and among non parasitemic dogs BA, 61% were non reactive, while the remainder showed at most titres of 1/16. The cut-off titres for IFAT and IHAT were 1/16 and 1/32 respectively, and for CFT and DAT 1/1 and 1/128 respectively. Sensitivity for IFAT, IHAT, CF and DAT were 95%, 84%, 97% and 95% respectively.

  14. Rapid profiling of the antigen regions recognized by serum antibodies using massively parallel sequencing of antigen-specific libraries.

    KAUST Repository

    Domina, Maria

    2014-12-04

    There is a need for techniques capable of identifying the antigenic epitopes targeted by polyclonal antibody responses during deliberate or natural immunization. Although successful, traditional phage library screening is laborious and can map only some of the epitopes. To accelerate and improve epitope identification, we have employed massive sequencing of phage-displayed antigen-specific libraries using the Illumina MiSeq platform. This enabled us to precisely identify the regions of a model antigen, the meningococcal NadA virulence factor, targeted by serum antibodies in vaccinated individuals and to rank hundreds of antigenic fragments according to their immunoreactivity. We found that next generation sequencing can significantly empower the analysis of antigen-specific libraries by allowing simultaneous processing of dozens of library/serum combinations in less than two days, including the time required for antibody-mediated library selection. Moreover, compared with traditional plaque picking, the new technology (named Phage-based Representation OF Immuno-Ligand Epitope Repertoire or PROFILER) provides superior resolution in epitope identification. PROFILER seems ideally suited to streamline and guide rational antigen design, adjuvant selection, and quality control of newly produced vaccines. Furthermore, this method is also susceptible to find important applications in other fields covered by traditional quantitative serology.

  15. EU-approved rapid tests might underestimate bovine spongiform encephalopathy infection in goats.

    Science.gov (United States)

    Meloni, Daniela; Bozzetta, Elena; Langeveld, Jan P M; Groschup, Martin H; Goldmann, Wilfred; Andrèoletti, Olivier; Lantier, Isabelle; Van Keulen, Lucien; Bossers, Alex; Pitardi, Danilo; Nonno, Romolo; Sklaviadis, Theodoros; Ingravalle, Francesco; Peletto, Simone; Colussi, Silvia; Acutis, Pier Luigi

    2017-03-01

    We report the diagnostic sensitivity of 3 EU-approved rapid tests (ELISAs; 1 from IDEXX and 2 from Bio-Rad) for the detection of transmissible spongiform encephalopathy diseases in goats. Ninety-eight goat brainstem samples were tested. All the rapid tests had 100% specificity and ≥80% sensitivity, with the IDEXX test significantly more sensitive than the 2 Bio-Rad tests. All tests detected 100% of samples from goats with clinical scrapie, but missed 8% (IDEXX) to 33% (Bio-Rad SG) of samples from preclinical goats. Importantly, only IDEXX picked up all samples from clinical bovine spongiform encephalopathy (BSE)-infected goats, whereas the other 2 rapid tests missed 15% (Bio-Rad SG) to 25% (Bio-Rad SAP). These results show that a fraction of preclinical scrapie infections are likely missed by EU surveillance, with sensitivity of detection strongly dependent on the choice of the rapid test. Moreover, a significant proportion of clinical BSE infections are underestimated by using either Bio-Rad test. Assuming that the same sensitivity on preclinical goats would also occur in BSE-infected goats, our data suggest that IDEXX is likely the most sensitive test for detecting preclinical field cases of BSE infection in goats, although with an 8% failure rate. These results raise some concerns about the reliability of current EU surveillance figures on BSE infection in goats.

  16. Acceptability of Rapid HIV Testing Among Latinos in Washington Heights, New York City, New York, USA.

    Science.gov (United States)

    Rowell-Cunsolo, Tawandra L; Cortes, Yamnia I; Long, Yue; Castro-Rivas, Erida; Liu, Jianfang

    2017-08-01

    In the United States, human immunodeficiency virus (HIV) has a disproportionately large impact on Latino Americans. This study assessed the acceptability of rapid HIV testing among a sample of Latinos from New York City. A cross-sectional study was conducted with 192 participants from The Washington Heights/Inwood Informatics Infrastructure for Community-Centered Comparative Effectiveness Research (WICER) study. Participants were interviewed and offered rapid HIV testing and post-test counseling. Seventy-five percent (n = 143) accepted rapid HIV testing when offered. More religious participants were less likely than less religious participants to undergo testing (RR = 0.73; 95% CI 0.54-0.99). Participants tested for HIV within the past year were less likely than those who had not been tested within the past year to agree to undergo testing (RR = 0.27; 95% CI 0.11-0.66). Community-based rapid HIV testing is feasible among Latinos in urban environments. Outreach efforts to engage religious individuals and encouraging routine testing should be reinforced.

  17. ClearColi BL21(DE3)-based expression of Zika virus antigens illustrates a rapid method of antibody production against emerging pathogens.

    Science.gov (United States)

    Viranaicken, Wildriss; Nativel, Brice; Krejbich-Trotot, Pascale; Harrabi, Wissal; Bos, Sandra; El Kalamouni, Chaker; Roche, Marjolaine; Gadea, Gilles; Desprès, Philippe

    2017-11-01

    Available rapid, simple and accurate methods for detection and diagnosis of emerging viral diseases are required. Recently, there was an urgent need for specific antibodies against mosquito-borne Zika virus (ZIKV), which is an emerging zoonotic disease of medical concern in different regions of the world. Here, we showed that overexpression of ZIKV antigens in ClearColi BL21(DE3), a bacteria strain expressing a non-endotoxic form of LPS, is suitable for the production of specific ZIKV antisera. Two major ZIKV antigenic domains, the domain III from envelope E glycoprotein, which brings the virus-specific epitopes, and the N-terminal region of nonstructural NS1 glycoprotein, which is responsible for pathophysiological conditions, were overexpressed in ClearColi BL21(DE3). Immunization of adult rat with insoluble recombinant ZIKV antigens in inclusion bodies resulted in the production of specific antibodies in a few weeks. Anti-E and anti-NS1 antibodies are efficient as biological tools for ZIKV detection by indirect ELISA and immunoblot assay. This method could successfully be applied to any emerging viruses. Copyright © 2017 Elsevier B.V. and Société Française de Biochimie et Biologie Moléculaire (SFBBM). All rights reserved.

  18. Rapid HIV testing for individuals on probation/parole: outcomes of an intervention trial.

    Science.gov (United States)

    Gordon, Michael S; Kinlock, Timothy W; McKenzie, Michelle; Wilson, Monique E; Rich, Josiah D

    2013-07-01

    Many probationers and parolees do not receive HIV testing despite being at increased risk for obtaining and transmitting HIV. A two-group randomized controlled trial was conducted between April, 2011 and May, 2012 at probation/parole offices in Baltimore, Maryland and Providence/Pawtucket, Rhode Island. Male and female probationers/parolees were interviewed (n = 1,263) and then offered HIV testing based on random assignment to one of two conditions: (1) On-site rapid HIV testing conducted at the probation/parole office; or (2) Referral for rapid HIV testing off site at a community HIV testing clinic. Outcomes were: (1) undergoing HIV testing; and (2) receipt of HIV testing results. Participants were significantly more likely to be tested on-site at a probation/parole office versus off-site at a HIV testing clinic (p < 0.001). There was no difference between the two groups in terms of receiving HIV testing results. Findings indicate that probationers/parolees are willing to be tested on-site and, independent of testing location, are equally willing to receive their results. Implications for expanding rapid HIV testing to more criminal justice related locations and populations are discussed.

  19. Comparison of PCR, Culture, and Direct Fluorescent-Antibody Testing for Detection of Bordetella pertussis

    Science.gov (United States)

    Loeffelholz, Mike J.; Thompson, Curt J.; Long, Karla S.; Gilchrist, Mary J. R.

    1999-01-01

    We prospectively compared the performance of culture, direct fluorescent-antibody testing (DFA), and an in-house-developed PCR test targeting the repeated insertion sequence IS481 for the detection of Bordetella pertussis in nasopharyngeal swab specimens. We tested 319 consecutive paired specimens on which all three tests were performed. A total of 59 specimens were positive by one or more tests. Of these, 5 were positive by all three tests, 2 were positive by culture and PCR, 16 were positive by PCR and DFA, 28 were positive by PCR only, and 8 were positive by DFA only. Any specimen positive by culture was considered to be a true positive, as were specimens positive by both PCR and DFA. Specimens positive only by PCR or DFA were considered discrepant, and their status was resolved by review of patient histories. Patients with symptoms meeting the Centers for Disease Control and Prevention clinical case definition for pertussis and who had a specimen positive by PCR or DFA were considered to have true B. pertussis infections. Of the 28 patients positive by PCR only, 20 met the clinical case definition for pertussis, while 3 of the 8 patients positive by DFA only met the clinical case definition. After resolution of the status of discrepant specimens, the sensitivity, specificity, positive predictive value, and negative predictive value were 15.2, 100, 100, and 87.5%, respectively, for culture; 93.5, 97.1, 84.3, and 98.9%, respectively, for PCR; and 52.2, 98.2, 82.8, and 92.4%, respectively, for DFA. The actual positive predictive value of PCR was probably greater, as several PCR-positive patients who did not meet the clinical case definition had symptoms consistent with typical or atypical pertussis. PCR is a sensitive and specific method for the detection of B. pertussis. PMID:10449467

  20. Cost-effectiveness of rapid syphilis screening in prenatal HIV testing programs in Haiti.

    Directory of Open Access Journals (Sweden)

    Bruce R Schackman

    2007-05-01

    Full Text Available New rapid syphilis tests permit simple and immediate diagnosis and treatment at a single clinic visit. We compared the cost-effectiveness, projected health outcomes, and annual cost of screening pregnant women using a rapid syphilis test as part of scaled-up prenatal testing to prevent mother-to-child HIV transmission in Haiti.A decision analytic model simulated health outcomes and costs separately for pregnant women in rural and urban areas. We compared syphilis syndromic surveillance (rural standard of care, rapid plasma reagin test with results and treatment at 1-wk follow-up (urban standard of care, and a new rapid test with immediate results and treatment. Test performance data were from a World Health Organization-Special Programme for Research and Training in Tropical Diseases field trial conducted at the GHESKIO Center Groupe Haitien d'Etude du Sarcome de Kaposi et des Infections Opportunistes in Port-au-Prince. Health outcomes were projected using historical data on prenatal syphilis treatment efficacy and included disability-adjusted life years (DALYs of newborns, congenital syphilis cases, neonatal deaths, and stillbirths. Cost-effectiveness ratios are in US dollars/DALY from a societal perspective; annual costs are in US dollars from a payer perspective. Rapid testing with immediate treatment has a cost-effectiveness ratio of $6.83/DALY in rural settings and $9.95/DALY in urban settings. Results are sensitive to regional syphilis prevalence, rapid test sensitivity, and the return rate for follow-up visits. Integrating rapid syphilis testing into a scaled-up national HIV testing and prenatal care program would prevent 1,125 congenital syphilis cases and 1,223 stillbirths or neonatal deaths annually at a cost of $525,000.In Haiti, integrating a new rapid syphilis test into prenatal care and HIV testing would prevent congenital syphilis cases and stillbirths, and is cost-effective. A similar approach may be beneficial in other resource

  1. Cost-effectiveness of rapid syphilis screening in prenatal HIV testing programs in Haiti.

    Science.gov (United States)

    Schackman, Bruce R; Neukermans, Christopher P; Fontain, Sandy N Nerette; Nolte, Claudine; Joseph, Patrice; Pape, Jean W; Fitzgerald, Daniel W

    2007-05-01

    New rapid syphilis tests permit simple and immediate diagnosis and treatment at a single clinic visit. We compared the cost-effectiveness, projected health outcomes, and annual cost of screening pregnant women using a rapid syphilis test as part of scaled-up prenatal testing to prevent mother-to-child HIV transmission in Haiti. A decision analytic model simulated health outcomes and costs separately for pregnant women in rural and urban areas. We compared syphilis syndromic surveillance (rural standard of care), rapid plasma reagin test with results and treatment at 1-wk follow-up (urban standard of care), and a new rapid test with immediate results and treatment. Test performance data were from a World Health Organization-Special Programme for Research and Training in Tropical Diseases field trial conducted at the GHESKIO Center Groupe Haitien d'Etude du Sarcome de Kaposi et des Infections Opportunistes in Port-au-Prince. Health outcomes were projected using historical data on prenatal syphilis treatment efficacy and included disability-adjusted life years (DALYs) of newborns, congenital syphilis cases, neonatal deaths, and stillbirths. Cost-effectiveness ratios are in US dollars/DALY from a societal perspective; annual costs are in US dollars from a payer perspective. Rapid testing with immediate treatment has a cost-effectiveness ratio of $6.83/DALY in rural settings and $9.95/DALY in urban settings. Results are sensitive to regional syphilis prevalence, rapid test sensitivity, and the return rate for follow-up visits. Integrating rapid syphilis testing into a scaled-up national HIV testing and prenatal care program would prevent 1,125 congenital syphilis cases and 1,223 stillbirths or neonatal deaths annually at a cost of $525,000. In Haiti, integrating a new rapid syphilis test into prenatal care and HIV testing would prevent congenital syphilis cases and stillbirths, and is cost-effective. A similar approach may be beneficial in other resource-poor countries

  2. Rapid Quantification of the Toxic Alga Prymnesium parvum in Natural Samples by Use of a Specific Monoclonal Antibody and Solid-Phase Cytometry

    Science.gov (United States)

    West, N. J.; Bacchieri, R.; Hansen, G.; Tomas, C.; Lebaron, P.; Moreau, H.

    2006-01-01

    The increasing incidence of harmful algal blooms around the world and their associated health and economic effects require the development of methods to rapidly and accurately detect and enumerate the target species. Here we describe use of a solid-phase cytometer to detect and enumerate the toxic alga Prymnesium parvum in natural samples, using a specific monoclonal antibody and indirect immunofluorescence. The immunoglobulin G antibody 16E4 exhibited narrow specificity in that it recognized several P. parvum strains and a Prymnesium nemamethecum strain but it did not cross-react with P. parvum strains from Scandinavia or any other algal strains, including species of the closely related genus Chrysochromulina. Prymnesium sp. cells labeled with 16E4 were readily detected by the solid-phase cytometer because of the large fluorescence signal and the signal/noise ratio. Immunofluorescence detection and enumeration of cultured P. parvum cells preserved with different fixatives showed that the highest cell counts were obtained when cells were fixed with either glutaraldehyde or formaldehyde plus the cell protectant Pluronic F-68, whereas the use of formaldehyde alone resulted in significantly lower counts. Immunofluorescence labeling and analysis with the solid-phase cytometer of fixed natural samples from a bloom of P. parvum occurring in Lake Colorado in Texas gave cell counts that were close to those obtained by the traditional method of counting using light microscopy. These results show that a solid-phase cytometer can be used to rapidly enumerate natural P. parvum cells and that it could be used to detect other toxic algae, with an appropriate antibody or DNA probe. PMID:16391128

  3. Qualitative evaluation of selective tests for detection of Neospora hughesi antibodies in serum and cerebrospinal fluid of experimentally infected horses.

    Science.gov (United States)

    Packham, Andrea E; Conrad, Patricia A; Wilson, W David; Jeanes, Lisa V; Sverlow, Karen W; Gardner, Ian A; Daft, Barbara M; Marsh, Antoinette E; Blagburn, Byron L; Ferraro, Gregory L; Barr, Bradd C

    2002-12-01

    Neospora hughesi is a newly recognized protozoan pathogen in horses that causes a myeloencephalitis similar to Sarcocystis neurona. There are no validated serologic tests using the gold standard sera that are currently available to detect specific N. hughesi antibodies and, thus, no tests available to detect antemortem exposure or estimate seroprevalence in the horse. The objectives of the present study were to establish a bank of gold standard equine sera through experimental infections with N. hughesi and to assess several serologic tests for the detection of related protozoan antibodies. Seven horses were inoculated with N. hughesi tachyzoites, and 7 horses received uninfected cell culture material. The horses were monitored, and blood and cerebrospinal fluid were collected repeatedly over a 4-mo period. With the sera, 4 different serologic techniques were evaluated. including a whole-parasite lysate enzyme-linked immunosorbent assay (ELISA), a recombinant protein ELISA, a modified direct agglutination test, and an indirect fluorescent antibody test. Qualitative and quantitative evaluation of the results showed that the N. hughesi indirect fluorescent antibody test (IFAT) consistently discriminated between experimentally infected and noninfected horses, using a cutoff of 1:640. Sera from 3 naturally infected horses had titers >1:640. Cerebrospinal fluid in all but I infected horse had very low N. hughesi IFAT titers (<1:160), starting at postinoculation day 30.

  4. Complement C3d conjugation to anthrax protective antigen promotes a rapid, sustained, and protective antibody response.

    Directory of Open Access Journals (Sweden)

    Ravi V Kolla

    Full Text Available B. anthracis is the causative agent of anthrax. Pathogenesis is primarily mediated through the exotoxins lethal factor and edema factor, which bind protective antigen (PA to gain entry into the host cell. The current anthrax vaccine (AVA, Biothrax consists of aluminum-adsorbed cell-free filtrates of unencapsulated B. anthracis, wherein PA is thought to be the principle target of neutralization. In this study, we evaluated the efficacy of the natural adjuvant, C3d, versus alum in eliciting an anti-PA humoral response and found that C3d conjugation to PA and emulsion in incomplete Freund's adjuvant (IFA imparted superior protection from anthrax challenge relative to PA in IFA or PA adsorbed to alum. Relative to alum-PA, immunization of mice with C3d-PA/IFA augmented both the onset and sustained production of PA-specific antibodies, including neutralizing antibodies to the receptor-binding portion (domain 4 of PA. C3d-PA/IFA was efficacious when administered either i.p. or s.c., and in adolescent mice lacking a fully mature B cell compartment. Induction of PA-specific antibodies by C3d-PA/IFA correlated with increased efficiency of germinal center formation and plasma cell generation. Importantly, C3d-PA immunization effectively protected mice from intranasal challenge with B. anthracis spores, and was approximately 10-fold more effective than alum-PA immunization or PA/IFA based on dose challenge. These data suggest that incorporation of C3d as an adjuvant may overcome shortcomings of the currently licensed aluminum-based vaccine, and may confer protection in the early days following acute anthrax exposure.

  5. The quality of rapid HIV testing in South Africa: an assessment of ...

    African Journals Online (AJOL)

    Abstract. Background: The aim of this study was to assess the quality of rapid HIV testing in South Africa. Method: A two-stage sampling procedure was used to select HCT sites in eight provinces of South Africa. The study employed both semi-structured interviews with HIV testers and observation of testing sessions as a ...

  6. The quality of rapid HIV testing in South Africa: an assessment of ...

    African Journals Online (AJOL)

    Background: The aim of this study was to assess the quality of rapid HIV testing in South Africa. Method: A two-stage sampling procedure was used to select HCT sites in eight provinces of South Africa. The study employed both semi-structured interviews with HIV testers and observation of testing sessions as a means of ...

  7. Response to “Rapid tests for HIV type discrimination in West Africa may perform differently”

    National Research Council Canada - National Science Library

    Tchounga, Boris K; Ekouevi, Didier K; Eholie, Serge P

    2015-01-01

    ... of each test used for the initial discrimination of HIV‐positive patients. Our team previously conducted in 2004 a field evaluation of rapid HIV serologic tests in Côte d'Ivoire and highlighted the lower accuracy of Genie II for differentiating between HIV‐1, HIV‐2 and dually reactive patients [ 4 ]. In our most recent study, the initial HIV diag...

  8. Response to "Rapid tests for HIV type discrimination in West Africa may perform differently"

    National Research Council Canada - National Science Library

    Tchounga, Boris K; Ekouevi, Didier K; Eholie, Serge P

    2015-01-01

    ... test used for the initial discrimination of HIV-positive patients. Our team previously conducted in 2004 a field evaluation of rapid HIV serologic tests in Cote d'Ivoire and highlighted the lower accuracy of Genie II for differentiating between HIV-1, HIV-2 and dually reactive patients [4]. In our most recent study, the initial HIV diagnostic te...

  9. Rapid test for fecal calprotectin levels in children with crohn disease

    DEFF Research Database (Denmark)

    Kolho, K L; Turner, D; Veereman-Wauters, G

    2012-01-01

    Assessment of fecal calprotectin, a surrogate marker of mucosal inflammation, is a promising means to monitor therapeutic response in pediatric inflammatory bowel disease, especially if the result is readily available. We tested the performance of a novel calprotectin rapid test, Quantum Blue...

  10. Prospective evaluation of three rapid diagnostic tests for diagnosis of human leptospirosis.

    NARCIS (Netherlands)

    M.G.A. Goris (Marga); M.M.G. Leeflang (Mariska); M. Lodén (Martin); J.F.P. Wagenaar (Jiri); P.R. Klatser (Paul); R.A. Hartskeerl (Rudy); K.R. Boer (Kimberly)

    2013-01-01

    markdownabstractDiagnosis of leptospirosis by the microscopic agglutination test (MAT) or by culture is confined to specialized laboratories. Although ELISA techniques are more common, they still require laboratory facilities. Rapid Diagnostic Tests (RDTs) can be used for easy point-of-care

  11. Rapid HIV Testing and Counselling in Labour in a Northern Nigeria ...

    African Journals Online (AJOL)

    Between April and August 2004, all pregnant women in labour at JUTH, were offered rapid HIV testing and counseling with opportunity to decline testing. HIV positive women were offered the standard nevirapine mono-therapy prophylaxis regimen (HIVNET 012). Four hundred and thirty (99.8%) of the 431 pregnant women ...

  12. Rapid acquisition of isolate-specific antibodies to chondroitin sulfate A-adherent Plasmodium falciparum isolates in Ghanaian primigravidae

    DEFF Research Database (Denmark)

    Cox, Sharon E; Staalsoe, Trine; Arthur, Paul

    2005-01-01

    vitamin A supplementation. Antibody responses to VSA(CSA) were detected within the first trimester of pregnancy and increased with increasing duration of pregnancy, and they seemed to be isolate specific, indicating that different CSA-adherent parasite lines express antigenically distinct VSA and thus may...... not be as antigenically conserved as has been previously suggested. Levels of anti-VSA(CSA) were not significantly associated with placental malarial infection determined by histology, indicating that primary immune responses to VSA(CSA) may not be sufficient to eradicate placental parasitemia in primigravidae....

  13. Rapid and sensitive detection of the food allergen glycinin in powdered milk using a lateral flow colloidal gold immunoassay strip test.

    Science.gov (United States)

    Wang, Yao; Deng, Ruiguang; Zhang, Gaiping; Li, Qingmei; Yang, Jifei; Sun, Yaning; Li, Zhixi; Hu, Xiaofei

    2015-03-04

    A rapid immunochromatographic lateral flow test strip in a sandwich format was developed with the colloidal gold-labeled mouse antiglycinin monoclonal antibody (mAb) and rabbit antiglycinin polyclonal antibody (pAb) to specifically identify glycinin, a soybean allergen. The test strip is composed of a sample pad, a conjugate reagent pad, an absorbent pad, and a test membrane containing a control line and a test line. This test strip has high sensitivity, and results can be obtained within 10 min without sophisticated procedures. The limit of detection (LOD) of the test strip was calculated to be 0.69 mg/kg using an optical density scanner that measures relative optical density. The assay showed high specificity for glycinin, with no cross-reactions with other soybean proteins or other food allergens. The recoveries of the lateral flow test strip in detecting glycinin in powdered milk samples ranged between 80.5 and 89.9% with relative standard deviations of less than 5.29% (intra-assay) and 6.72% (interassay). Therefore, the test strip is useful as a quantitative, semiquantitative, or qualitative detection method for glycinin in powdered milk. In addition, the test strip can be used to detect glycinin in other processed foods and may be a valuable tool in identifying effective approaches for reducing the impact of glycinin.

  14. Susceptibility testing of filamentous fungi to amphotericin B by a rapid radiometric method

    Energy Technology Data Exchange (ETDEWEB)

    Merz, W.G.; Fay, D.; Thumar, B.; Dixon, D.

    1984-01-01

    A rapid, radiometric method was developed to determine the susceptibility of filamentous fungi to amphotericin B. The rapid, radiometric method depended on measurement of the inhibition of /sup 24/CO/sub 2/ production in the presence of amphotericin B. Thirty isolates of filamentous fungi were tested by the rapid, radiometric method and a reference agar dilution method. There was 93% agreement between the two methods when an 80% or greater decrease in CO/sub 2/ production was used to calculate the minimal inhibitory concentration with the rapid, radiometric method. Minimal inhibitory concentrations, based on 80% decrease of CO/sub 2/ production, were achieved within 24 h of incubation with all of the fungi tested.

  15. Anti-tissue transglutaminase antibodies in patients with abnormal liver tests: is it always coeliac disease?

    Science.gov (United States)

    Lo Iacono, Oreste; Petta, Salvatore; Venezia, Giovanna; Di Marco, Vito; Tarantino, Giuseppe; Barbaria, Francesco; Mineo, Claudia; De Lisi, Stefania; Almasio, Piero Luigi; Craxì, Antonio

    2005-11-01

    Coeliac disease (CD) is found in 5-10% of patients with chronically abnormal liver tests and no obvious cause of liver disease. In this population the efficacy of screening for CD by anti-tissue transglutaminase (anti-tTG) may be impaired by the high rate of positive anti-tTG found in chronic liver disease. To evaluate the prevalence of coeliac disease and the role of anti-tTG in patients with non-viral, non-autoimmune chronic and no obvious cause of liver damage. Out of 2,512 consecutive patients with abnormal liver tests, 168 (118 men, 50 women; mean age 40.7 +/- 12.6 years) were defined, on the basis of clinical data and liver biopsy, as NAFLD or cryptogenic chronic hepatitis. All were tested by recombinant IgA and IgG anti-tissue transglutaminase. Patients with a positive serology underwent endoscopy with duodenal biopsies. NAFLD was diagnosed in 121 patients, in 6 associated with cirrhosis, while 47 patients were considered as cryptogenic hepatitis in the absence of steatosis. Anti-tTG were positive in 20/168 patients (3 IgA alone; 11 IgG alone; 6 both IgA and IgG). Coeliac disease was found at endoscopy and confirmed by histopathology only in the 6 patients (3.6%) with both IgA and IgG anti-tTG positivity. Four of the patients with CD had NAFLD (3.3%), in 2 of them associated with cirrhosis; while 2 of those with cryptogenic hepatitis (4.2%) had CD. The prevalence of CD in patients with chronically abnormal liver tests of unexplained etiology is 4%, with no relation with the degree of liver steatosis. Screening should be done by testing for IgA and IgG antibodies and then evaluating by endoscopy and biopsy only patients positive for both.

  16. Dipstick test for rapid diagnosis of Shigella dysenteriae 1 in bacterial cultures and its potential use on stool samples.

    Science.gov (United States)

    Taneja, Neelam; Nato, Faridabano; Dartevelle, Sylvie; Sire, Jean Marie; Garin, Benoit; Thi Phuong, Lan Nguyen; Diep, Tai The; Shako, Jean Christophe; Bimet, François; Filliol, Ingrid; Muyembe, Jean-Jacques; Ungeheuer, Marie Noëlle; Ottone, Catherine; Sansonetti, Philippe; Germani, Yves

    2011-01-01

    We describe a test for rapid detection of S. dysenteriae 1 in bacterial cultures and in stools, at the bedside of patients. The test is based on the detection of S. dysenteriae 1 lipopolysaccharide (LPS) using serotype 1-specific monoclonal antibodies coupled to gold particles and displayed on a one-step immunochromatographic dipstick. A concentration as low as 15 ng/ml of LPS was detected in distilled water and in reconstituted stools in 10 minutes. In distilled water and in reconstituted stools, an unequivocal positive reaction was obtained with 1.6×10⁶ CFU/ml and 4.9×10⁶ CFU/ml of S. dysenteriae 1, respectively. Optimal conditions to read the test have been determined to limit the risk of ambiguous results due to appearance of a faint yellow test band in some negative samples. The specificity was 100% when tested with a battery of Shigella and unrelated strains in culture. When tested on 328 clinical samples in India, Vietnam, Senegal and France by laboratory technicians and in Democratic Republic of Congo by a field technician, the specificity (312/316) was 98.7% (95% CI:96.6-99.6%) and the sensitivity (11/12) was 91.7% (95% CI:59.8-99.6%). Stool cultures and the immunochromatographic test showed concordant results in 98.4 % of cases (323/328) in comparative studies. Positive and negative predictive values were 73.3% (95% CI:44.8-91.1%) and 99.7% (95% CI:98-100%). The initial findings presented here for a simple dipstick-based test to diagnose S. dysenteriae 1 demonstrates its promising potential to become a powerful tool for case management and epidemiological surveys.

  17. India Ink Staining, a Rapid and Affordable Test for Diagnosis of Cryptococcal Meningitis

    OpenAIRE

    Masfiyah Masfiyah

    2016-01-01

    Cryptococcal meningitis incidence has increased along with an increase in incidence of HIV-AIDS. This infection causes increased morbidity and mortality in patients with HIV-AIDS. A rapid diagnosis plays an important role to ensure a prompt therapy of the disease. The cryptococcal polysaccharide antigen test for diagnosis of meningitis is rapid but relatively expensive while culture is time consuming. A 47-year man was admitted to hospital with a headache, fever, nausea, and vomiting and ...

  18. Colloidal gold-based immunochromatographic strip test compromising optimised combinations of anti-S. suis capsular polysaccharide polyclonal antibodies for detection of Streptococcus suis.

    Science.gov (United States)

    Nakayama, Tatsuya; Zhao, Jizi; Takeuchi, Dan; Kerdsin, Anusack; Chiranairadul, Piphat; Areeratana, Prasanee; Loetthong, Phacharaphan; Pienpringam, Anupong; Akeda, Yukihiro; Oishi, Kazunori

    2014-10-15

    A rapid diagnosis kit that detects Streptococcus suis (S. suis) antigens from urine with an immunochromatographic stripe (ICS) test was developed in this study. The ICS test was produced using colloidal gold coated with polyclonal antibodies (pAbs) against S. suis. The pAbs were developed from rabbits immunised with S. suis serotype 2 capsular polysaccharides (CPS). Development of the pAbs was investigated to establish their binding to CPS and to determine the maximum sensitivity of two combination antibodies for the ICS test. The results of the ICS optimisation revealed that the combinations of pAb C-N1 and pAb C-N2 had the highest sensitivity to CPS. The minimum limitation of ICS sensitivity indicated 1.0 × 10(4) colony forming units (CFU) and a CPS concentration of 0.05 µg. The assay time for detection of S. suis antigens is less than 15 min, which is suitable for rapid detection. A cross-reactive test was also conducted, and it detected no other bacteria (Streptococcus pneumoniae, Streptococcus agalactiae, Staphylococcus aureus, Enterococcus faecalis, Escherichia coli, Pseudomonas aeruginosa, and Klebsiella pneumoniae). The cross-reactivity of other serotypes in S. suis was also investigated, and tests for serotypes of 1, 1/2, 3, 4, 5, 6, 7, 8, 9, 14, and 16 were positive. This study presents the first report of a development of an ICS that enables the quantitative detection of streptococcal antigens. The S. suis ICS provides several advantages over other methods, including the speed and simplicity of use. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Should we offer routine hepatitis C antibody testing in men who have sex with men?

    Directory of Open Access Journals (Sweden)

    Christopher Ward

    2014-11-01

    Full Text Available Introduction: There has been a significant rise in the number of HIV positive men who have sex with men (MSM co-infected with hepatitis C (HCV. Most infections are thought to occur through high risk sexual practices, exacerbated by drug use. Previous data has suggested no need for routine screening in HIV negative MSM. We looked at HCV antibody testing and HCV risk assessment in all MSM clinic attenders as part of a Public Health England initiative. Materials and Methods: Routine HCV antibody testing was offered to all MSM attending a large inner city sexual health clinic from April to June 2014. Patients were asked to fill in a questionnaire assessing HCV risk. Demographic data, HIV status and STI results were collected and compared. Results: We collected 471 HCV risk assessment questionnaires during the eight-week period. The median age was 34 (range 18–71 and 403 (85.6% were White British. Ten (2.1% patients were known to be HCV positive, of which 3 were on treatment and 5 (1.1% had cleared HCV. One hundred and forty-nine (31.6% patients were HIV negative, 254 (53.9% were HIV positive and 68 (14.5% had unknown HIV status at time of clinic visit. In the last three months 151 (32.1% reported unprotected receptive anal intercourse, 58 (12.3% reported group sex, 11 (2.3% reported receptive fisting and 32 (6.8% reported more than 10 partners. Eighty-seven (18.5% patients had shared notes/straws to snort drugs and 29 (6.2% reported injecting drugs or slamming. One hundred and forty-two (30.0% patients reported recreational drug use in the last 12 months, with cocaine, methadrone and ketamine most popular. One hundred and fifteen (24.4% patients reported sex under the influence of recreational drugs. There were no statistical differences between HIV positive and HIV negative patients in their risk, sexual behaviour and drug use. STI screens were performed on 269 patients with nine (3.3% new HIV diagnoses, four (1.5% early syphilis, and 28 (10

  20. Should we offer routine hepatitis C antibody testing in men who have sex with men?

    Science.gov (United States)

    Ward, Christopher; Lee, Vincent

    2014-01-01

    There has been a significant rise in the number of HIV positive men who have sex with men (MSM) co-infected with hepatitis C (HCV). Most infections are thought to occur through high risk sexual practices, exacerbated by drug use. Previous data has suggested no need for routine screening in HIV negative MSM. We looked at HCV antibody testing and HCV risk assessment in all MSM clinic attenders as part of a Public Health England initiative. Routine HCV antibody testing was offered to all MSM attending a large inner city sexual health clinic from April to June 2014. Patients were asked to fill in a questionnaire assessing HCV risk. Demographic data, HIV status and STI results were collected and compared. We collected 471 HCV risk assessment questionnaires during the eight-week period. The median age was 34 (range 18-71) and 403 (85.6%) were White British. Ten (2.1%) patients were known to be HCV positive, of which 3 were on treatment and 5 (1.1%) had cleared HCV. One hundred and forty-nine (31.6%) patients were HIV negative, 254 (53.9%) were HIV positive and 68 (14.5%) had unknown HIV status at time of clinic visit. In the last three months 151 (32.1%) reported unprotected receptive anal intercourse, 58 (12.3%) reported group sex, 11 (2.3%) reported receptive fisting and 32 (6.8%) reported more than 10 partners. Eighty-seven (18.5%) patients had shared notes/straws to snort drugs and 29 (6.2%) reported injecting drugs or slamming. One hundred and forty-two (30.0%) patients reported recreational drug use in the last 12 months, with cocaine, methadrone and ketamine most popular. One hundred and fifteen (24.4%) patients reported sex under the influence of recreational drugs. There were no statistical differences between HIV positive and HIV negative patients in their risk, sexual behaviour and drug use. STI screens were performed on 269 patients with nine (3.3%) new HIV diagnoses, four (1.5%) early syphilis, and 28 (10.4%) rectal gonorrhoea infections. There were three (1

  1. Rapid HIV testing experience at Veterans Affairs North Texas Health Care System's Homeless Stand Downs.

    Science.gov (United States)

    Hooshyar, Dina; Surís, Alina M; Czarnogorski, Maggie; Lepage, James P; Bedimo, Roger; North, Carol S

    2014-01-01

    In the USA, 21% of the estimated 1.1 million people living with human immunodeficiency virus/acquired immune deficiency syndrome (HIV/AIDS) are unaware they are HIV-infected. In 2011, Veterans Health Administration (VHA)'s Office of Public Health in conjunction with VHA's Health Care for Homeless Veterans Program funded grants to support rapid HIV testing at homeless outreach events because homeless populations are more likely to obtain emergent rather than preventive care and have a higher HIV seroprevalence as compared to the general population. Because of a Veterans Affairs North Texas Health Care System (VANTHCS)'s laboratory testing requirement, VANTHCS partnered with community agencies to offer rapid HIV testing for the first time at VANTHCS' 2011 Homeless Stand Downs in Dallas, Fort Worth, and Texoma, Texas. Homeless Stand Downs are outreach events that connect Veterans with services. Veterans who declined testing were asked their reasons for declining. Comparisons by Homeless Stand Down site used Pearson χ², substituting Fisher's Exact tests for expected cell sizes Veterans attending the Homeless Stand Downs, 261 Veterans reported reasons for declining HIV testing, and 133 Veterans were tested, where 92% of the tested Veterans obtained their test results at the events - all tested negative. Veterans' reported reasons for declining HIV testing included previous negative result (n=168), no time to test (n=49), no risk factors (n=36), testing is not a priority (n=11), uninterested in knowing serostatus (n=6), and HIV-infected (n=3). Only "no time to test" differed significantly by Homeless Stand Down site. Nonresponse rate was 54%. Offering rapid HIV testing at Homeless Stand Downs is a promising testing venue since 15% of Veterans attending VANTHCS' Homeless Stand Downs were tested for HIV, and majority obtained their HIV test results at point-of-care while further research is needed to determine how to improve these rates.

  2. PrimaTB STAT-PAK Assay, a Novel, Rapid Lateral-Flow Test for Tuberculosis in Nonhuman Primates

    NARCIS (Netherlands)

    Lyashchenko, K.P.; Greenwald, R.; Esfandiari, J.; Greenwald, D.; Nacy, C.A.; Gibson, S.; Didier, P.J.; Washington, M.; Szczerba, P.; Motzel, S.; Handt, L.; Pollock, J.M.; McNair, J.; Andersen, P.; Langermans, J.A.M.; Verreck, F.; Ervin, S.; Ervin, F.; McCombs, C.

    2007-01-01

    Tuberculosis (TB) is the most important zoonotic bacterial disease in nonhuman primates (NHP). The current diagnostic method, the intradermal palpebral tuberculin test, has serious shortcomings. We characterized antibody responses in NHP against Mycobacterium tuberculosis to identify immunodominant

  3. Novel gold nanoparticle trimer reporter probe combined with dry-reagent cotton thread immunoassay device for rapid human ferritin test.

    Science.gov (United States)

    Mao, Xun; Du, Ting-E; Meng, Lili; Song, Tingting

    2015-08-19

    We reported here for the first time on the use of cotton thread combined with novel gold nanoparticle trimer reporter probe for low-cost, sensitive and rapid detection of a lung cancer related biomarker, human ferritin. A model system comprising ferritin as an analyte and a pair of monoclonal antibodies was used to demonstrate the proof-of-concept on the dry-reagent natural cotton thread immunoassay device. Results indicated that the using of novel gold nanoparticle trimer reporter probe greatly improved the sensitivity comparing with traditional gold nanoparticle reporter probe on the cotton thread immunoassay device. The assay avoids multiple incubation and washing steps performed in most conventional protein analyses. Although qualitative tests are realized by observing the color change of the test zone, quantitative data are obtained by recording the optical responses of the test zone with a commercial scanner and corresponding analysis software. Under optimal conditions, the cotton thread immunoassay device was capable of measuring 10 ng/mL human ferritin under room temperature which is sensitive enough for clinical diagnosis. Moreover, the sample solution employed in the assays is just 8 μL, which is much less than traditional lateral flow strip based biosensors. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Screening and Monitoring Coeliac Disease: Multicentre Trial of a New Serum Antibody Test Kit

    Directory of Open Access Journals (Sweden)

    Peter L. Devine

    1994-01-01

    average interassay CV was 6.4% for IgA and 4.3% for IgG (n=3. By defining a positive te st as both IgA and IgG elevated, a sensitivity of 93% in untreated coeliacs (n=75 was observed. The corresponding specificities in healthy adults (n=130 and healthy children (n=77 were >99% and 100% respectively, while in patients with other gastrointestinal disorders (disease controls the specificity was 94% (n=129. The test was also useful in monitoring patients, with anti-gliadin IgA and IgG falling for up to a year after commencing a gluten-free diet (GFD (12 adults. In some patients however, antibody levels did not reach the normal cutpoint after many months on a GFD, which may reflect the patients ' poor adherence to their gluten free diet. The test was superior to the Pharmacia anti-gliadin ELISA, and should be useful as an aid to the diagnosis of coeliac disease, as well as in the follow-up of treated patients.

  5. Sensitivity and specificity of point-of-care rapid combination syphilis-HIV-HCV tests.

    Directory of Open Access Journals (Sweden)

    Kristen L Hess

    Full Text Available New rapid point-of-care (POC tests are being developed that would offer the opportunity to increase screening and treatment of several infections, including syphilis. This study evaluated three of these new rapid POC tests at a site in Southern California.Participants were recruited from a testing center in Long Beach, California. A whole blood specimen was used to evaluate the performance of the Dual Path Platform (DPP Syphilis Screen & Confirm, DPP HIV-Syphilis, and DPP HIV-HCV-Syphilis rapid tests. The gold-standard comparisons were Treponema pallidum passive particle agglutination (TPPA, rapid plasma reagin (RPR, HCV enzyme immunoassay (EIA, and HIV-1/2 EIA.A total of 948 whole blood specimens were analyzed in this study. The sensitivity of the HIV tests ranged from 95.7-100% and the specificity was 99.7-100%. The sensitivity and specificity of the HCV test were 91.8% and 99.3%, respectively. The treponemal-test sensitivity when compared to TPPA ranged from 44.0-52.7% and specificity was 98.7-99.6%. The non-treponemal test sensitivity and specificity when compared to RPR was 47.8% and 98.9%, respectively. The sensitivity of the Screen & Confirm test improved to 90.0% when cases who were both treponemal and nontreponemal positive were compared to TPPA+/RPR ≥ 1 ∶ 8.The HIV and HCV on the multi-infection tests showed good performance, but the treponemal and nontreponemal tests had low sensitivity. These results could be due to a low prevalence of active syphilis in the sample population because the sensitivity improved when the gold standard was limited to those more likely to be active cases. Further evaluation of the new syphilis POC tests is required before implementation into testing programs.

  6. Sensitivity and specificity of point-of-care rapid combination syphilis-HIV-HCV tests.

    Science.gov (United States)

    Hess, Kristen L; Fisher, Dennis G; Reynolds, Grace L

    2014-01-01

    New rapid point-of-care (POC) tests are being developed that would offer the opportunity to increase screening and treatment of several infections, including syphilis. This study evaluated three of these new rapid POC tests at a site in Southern California. Participants were recruited from a testing center in Long Beach, California. A whole blood specimen was used to evaluate the performance of the Dual Path Platform (DPP) Syphilis Screen & Confirm, DPP HIV-Syphilis, and DPP HIV-HCV-Syphilis rapid tests. The gold-standard comparisons were Treponema pallidum passive particle agglutination (TPPA), rapid plasma reagin (RPR), HCV enzyme immunoassay (EIA), and HIV-1/2 EIA. A total of 948 whole blood specimens were analyzed in this study. The sensitivity of the HIV tests ranged from 95.7-100% and the specificity was 99.7-100%. The sensitivity and specificity of the HCV test were 91.8% and 99.3%, respectively. The treponemal-test sensitivity when compared to TPPA ranged from 44.0-52.7% and specificity was 98.7-99.6%. The non-treponemal test sensitivity and specificity when compared to RPR was 47.8% and 98.9%, respectively. The sensitivity of the Screen & Confirm test improved to 90.0% when cases who were both treponemal and nontreponemal positive were compared to TPPA+/RPR ≥ 1 ∶ 8. The HIV and HCV on the multi-infection tests showed good performance, but the treponemal and nontreponemal tests had low sensitivity. These results could be due to a low prevalence of active syphilis in the sample population because the sensitivity improved when the gold standard was limited to those more likely to be active cases. Further evaluation of the new syphilis POC tests is required before implementation into testing programs.

  7. Veterans health administration hepatitis B testing and treatment with anti-CD20 antibody administration.

    Science.gov (United States)

    Hunt, Christine M; Beste, Lauren A; Lowy, Elliott; Suzuki, Ayako; Moylan, Cynthia A; Tillmann, Hans L; Ioannou, George N; Lim, Joseph K; Kelley, Michael J; Provenzale, Dawn

    2016-05-21

    To evaluate pretreatment hepatitis B virus (HBV) testing, vaccination, and antiviral treatment rates in Veterans Affairs patients receiving anti-CD20 Ab for quality improvement. We performed a retrospective cohort study using a national repository of Veterans Health Administration (VHA) electronic health record data. We identified all patients receiving anti-CD20 Ab treatment (2002-2014). We ascertained patient demographics, laboratory results, HBV vaccination status (from vaccination records), pharmacy data, and vital status. The high risk period for HBV reactivation is during anti-CD20 Ab treatment and 12 mo follow up. Therefore, we analyzed those who were followed to death or for at least 12 mo after completing anti-CD20 Ab. Pretreatment serologic tests were used to categorize chronic HBV (hepatitis B surface antigen positive or HBsAg+), past HBV (HBsAg-, hepatitis B core antibody positive or HBcAb+), resolved HBV (HBsAg-, HBcAb+, hepatitis B surface antibody positive or HBsAb+), likely prior vaccination (isolated HBsAb+), HBV negative (HBsAg-, HBcAb-), or unknown. Acute hepatitis B was defined by the appearance of HBsAg+ in the high risk period in patients who were pretreatment HBV negative. We assessed HBV antiviral treatment and the incidence of hepatitis, liver failure, and death during the high risk period. Cumulative hepatitis, liver failure, and death after anti-CD20 Ab initiation were compared by HBV disease categories and differences compared using the χ(2) test. Mean time to hepatitis peak alanine aminotransferase, liver failure, and death relative to anti-CD20 Ab administration and follow-up were also compared by HBV disease group. Among 19304 VHA patients who received anti-CD20 Ab, 10224 (53%) had pretreatment HBsAg testing during the study period, with 49% and 43% tested for HBsAg and HBcAb, respectively within 6 mo pretreatment in 2014. Of those tested, 2% (167/10224) had chronic HBV, 4% (326/7903) past HBV, 5% (427/8110) resolved HBV, 8% (628

  8. [Introduction of a rapid HIV test in Sexually Transmitted Infections Units].

    Science.gov (United States)

    Cuesta, María del Mar; López, María del Carmen; Nieto, Paula; Junquera, María Luisa; Varela, José Antonio; Vázquez, Fernando

    2012-04-01

    The aim of the study was to analyze the implementation of a rapid HIV test in Asturias (Spain). The study was conducted in two STI Units using the Determine® HIV-1/2 test. A total of 1011 people were tested, of whom 65.3% had never been tested for HIV previously, and 71.4% were heterosexual men. Twenty-one tests were confirmed positive by Enzyme Immunoassay/Western Blot (EIA/WB) assay An increase was observed in the diagnosis of HIV. Awareness campaigns and rapid tests could be effective methods for the early diagnosis of HIV. Copyright © 2010 Elsevier España, S.L. All rights reserved.

  9. Factors Associated With Receiving Rapid HIV Testing Among Individuals on Probation or Parole.

    Science.gov (United States)

    Gordon, Michael S; Carswell, Steven B; Wilson, Monique; Kinlock, Timothy W; Restivo, Lauren; McKenzie, Michelle; Rich, Josiah D

    2016-10-01

    Despite the strong correlation between HIV and corrections, testing and prevention efforts have largely been ignored among community corrections populations. The current study is a secondary analysis to compare characteristics of individuals under community corrections supervision who completed rapid HIV testing with those who refused such testing (N = 2,382) in Baltimore, Maryland, and Providence, Rhode Island. Results indicate that the following variables were significantly associated with the receipt of rapid HIV testing: being female (p = .024), Black race (p = .004), homeless (p = .016), early age of crime onset (p = .001), more drug use during the past 90 days (p = .033), and previously tested for hepatitis C virus/hepatitis B virus (p = .024). Such findings make it especially important that individuals under community supervision be linked with services in the community to ensure that HIV testing and health care planning occur simultaneously. © The Author(s) 2016.

  10. Comparison of two rapid influenza A/B test kits with reference methods showing high specificity and sensitivity for influenza A infection.

    Science.gov (United States)

    Booth, Susanne; Baleriola, Cristina; Rawlinson, William D

    2006-05-01

    The rapid detection of influenza viruses is important for forming preventative strategies, directing initiation of anti-viral therapy, detecting potential avian influenza viruses, and excluding influenza-like pathogens, such as SARS. The ImmunoCard STAT! Flu A and B Plus test (Meridian Bioscience, Cincinnati, OH) is a new point of care (POC) test utilizing influenza-specific monoclonal antibodies for rapid diagnosis. The performance of this assay was compared to the established POC Binax NowFlu A and NowFlu B test, and the reference diagnostic standards of viral culture, indirect immunofluorescence (IFA), and RT-PCR where appropriate. Testing of nasopharyngeal aspirates (NPA) from children, throat swabs, and nasal swabs from adults indicated ImmunoCard STAT! specificity of 98% and 100% for influenza A and B, respectively in 224 specimens. The Binax test showed specificity of 99% and 100%, respectively for influenza A and B. Sensitivity results were identical for both rapid detection kits (80% and 47% for Flu A and B, respectively). Overall results were very similar for both testing devices with the advantage of ImmunoCard STAT! Flu A and B Plus test detecting influenza A and B with sharp and easy to read results. Copyright 2006 Wiley-Liss, Inc.

  11. Rabies and bats in a rabies-endemic area of southern Africa: application of two commercial test kits for antigen and antibody detection.

    Science.gov (United States)

    Oelofsen, M J; Smith, M S

    1993-09-01

    In southern Africa, isolates of rabies-related viruses (i.e. Duvenhage virus and Lagos bat virus) have been made from insectivorous and frugivorous bats. As no recent formal bat virus survey has been reported in southern Africa, a survey of bats in rabies-endemic areas was undertaken. Five hundred and forty-seven bats (13 species) were collected from 21 localities in the Orange Free State, Lesotho and the northern Cape Province. None of the 190 bat sera tested using the "Trousse Platelia Rage" ELISA kit (Diagnostic Pasteur), had antibodies to rabies virus glycoprotein G. Rabies virus nucleocapsid antigen was also sought for in the brains of 530 bats (13 species) by means of the "Rapid rabies enzyme immunodiagnosis" (RREID) test (Diagnostics Pasteur). No positive results were obtained. These results show that bats are unlikely to play an important role as hosts of rabies in these parts of Africa, although a low rate of infection cannot be excluded.

  12. Use of the anti-endomysial antibody test to diagnose coeliac disease in clinical practice.

    Science.gov (United States)

    Pearce, Allum B; Sinclair, David; Duncan, Hamish D; Saas, Myk; Poller, David N

    2002-01-01

    Guidelines suggest that duodenal biopsies should be taken in patients with iron deficiency anaemia. To examine anti-endomysial antibody (anti-EMA) and duodenal biopsy testing in Portsmouth, UK. To evaluate if the current pathology workload can be reduced by anti-EMA replacing some duodenal biopsies. To determine to what extent doctors in Portsmouth are confirming a positive anti-EMA test by small bowel biopsy. Patients' records were examined firstly from whom duodenal biopsies were taken between April 1999 and September 2000, and secondly who had anti-EMA tested between December 1999 and September 2000. Queen Alexandra Hospital, UK. District General Hospital. Medical Outpatients Department. In the first group, of 354 patients undergoing duodenal biopsy, 108 patients had anti-EMA tested. Of these 108 patients, 25 had positive IgA anti-EMA and 83 had negative IgA anti-EMA. Of these 83 patients who had negative IgA EMA, 8 patients had a duodenal biopsy suggestive of Coeliac Disease. 4 of these 8 patients were on gluten free diets at the time of anti-EMA testing so were excluded. 1 of the 4 patients who had a duodenal biopsy indicative of Coeliac Disease had a positive IgG anti-EMA despite negative IgA anti-EMA. Therefore 3 false negative IgG anti-EMA were ultimately identified giving a sensitivity of 89% and a specificity of 100%. On follow up one has subsequently been found to have T-cell lymphoma; if this patient is taken into account the sensitivity of anti-EMA increases to 93%. In the second group; 1450 patients had anti-EMA tested. Of the 67 positive anti-EMA tests in this group only 12 had a duodenal biopsy. Many patients who have been tested for anti-EMA are not offered duodenal biopsy in Portsmouth despite current British Society of Gastroenterology (BSG) guidelines, although it should be noted that the BSG guidelines on iron-deficiency anaemia recommend using anti-EMA without histology to exclude Coeliac Disease in menstruating women (biopsy would still be

  13. Systematic review of the performance of rapid rifampicin resistance testing for drug-resistant tuberculosis.

    Directory of Open Access Journals (Sweden)

    Matthew Arentz

    Full Text Available INTRODUCTION: Rapid tests for rifampicin resistance may be useful for identifying isolates at high risk of drug resistance, including multidrug-resistant TB (MDR-TB. However, choice of diagnostic test and prevalence of rifampicin resistance may both impact a diagnostic strategy for identifying drug resistant-TB. We performed a systematic review to evaluate the performance of WHO-endorsed rapid tests for rifampicin resistance detection. METHODS: We searched MEDLINE, Embase and the Cochrane Library through January 1, 2012. For each rapid test, we determined pooled sensitivity and specificity estimates using a hierarchical random effects model. Predictive values of the tests were determined at different prevalence rates of rifampicin resistance and MDR-TB. RESULTS: We identified 60 publications involving six different tests (INNO-LiPA Rif. TB assay, Genotype MTBDR assay, Genotype MTBDRplus assay, Colorimetric Redox Indicator (CRI assay, Nitrate Reductase Assay (NRA and MODS tests: for all tests, negative predictive values were high when rifampicin resistance prevalence was ≤ 30%. However, positive predictive values were considerably reduced for the INNO-LiPA Rif. TB assay, the MTBDRplus assay and MODS when rifampicin resistance prevalence was < 5%. LIMITATIONS: In many studies, it was unclear whether patient selection or index test performance could have introduced bias. In addition, we were unable to evaluate critical concentration thresholds for the colorimetric tests. DISCUSSION: Rapid tests for rifampicin resistance alone cannot accurately predict rifampicin resistance or MDR-TB in areas with a low prevalence of rifampicin resistance. However, in areas with a high prevalence of rifampicin resistance and MDR-TB, these tests may be a valuable component of an MDR-TB management strategy.

  14. Wind Tunnel Model Design and Test Using Rapid Prototype Materials and Processes

    Science.gov (United States)

    2001-07-23

    UNCLASSIFIED WIND TUNNEL MODEL DESIGN AND TEST USING RAPID PROTOTYPE MATERIALS AND PROCESSES Richard R. Heisler and Clifford L. Ratliff The Johns Hopkins...deflection, and attach directly to the strongback with screws. A and tolerance deviations when the material was grown. schematic diagram of the RPM...constructed around the clay to contain the I. R. R. Heisler , "Final Test Report for the Wind pouring of silicon resin. Tunnel Test of the JHU/APL WTM-01 at

  15. Leveraging rapid community-based hiv testing campaigns for non-communicable diseases in rural uganda

    OpenAIRE

    Gabriel Chamie; Dalsone Kwarisiima; Clark, Tamara D; Jane Kabami; Vivek Jain; Elvin Geng; Petersen, Maya L; Harsha Thirumurthy; Moses R Kamya; Havlir, Diane V.; Charlebois, Edwin D.

    2012-01-01

    Background The high burden of undiagnosed HIV in sub-Saharan Africa limits treatment and prevention efforts. Community-based HIV testing campaigns can address this challenge and provide an untapped opportunity to identify non-communicable diseases (NCDs). We tested the feasibility and diagnostic yield of integrating NCD and communicable diseases into a rapid HIV testing and referral campaign for all residents of a rural Ugandan parish. Methods A five-day, multi-disease campaign, offering diag...

  16. Comparison between the Traditional and a Rapid Screening Test for Cryoimmunoglobulins Detection

    Directory of Open Access Journals (Sweden)

    Federica Romitelli

    2015-01-01

    Full Text Available Objectives. A new rapid, automatic, and sensitive screening test useful to detect cryoglobulins in serum samples is proposed. Design and Methods. The increase of turbidity during the cryoglobulin aggregation was monitored spectrophotometrically in sera from 400 patients with clinical evidence of cryoglobulinemia related disorders and 100 controls. Results were correlated to those obtained by the traditional method. Results. Kinetics of the aggregation curves were described by their maximum turbidity increase, lag time, and slope. Despite a partial correspondence between the traditional and the rapid test, patients with symptomatic cryoglobulinemia showed turbidity values significantly higher than the determined cutoff. Moreover, a functional classification of cryoglobulins is proposed. Conclusions. Due to its high reproducibility, operator independence, low cost, and results obtained within 2 hours, the rapid test can be used as a “real time” monitoring of cryoglobulinemia related diseases and for the evaluation of plasmapheresis efficacy.

  17. Rapid and simple IgG specific test for the exclusion of heparin induced thrombocytopenia (HIT).

    Science.gov (United States)

    Kolde, Hans-Jürgen; Dostatni, Ralf; Mauracher, Susanne

    2011-08-29

    The exclusion of heparin induced thrombocytopenia (HIT) is required for selecting the most appropriate anticoagulation therapy in affected patients. It requires the combination of clinical data with the detection of antibodies directed against platelet factor 4 (PF4) in complex with polyanions (PA) such as heparin. We developed a lateral flow immunoassay (LFIA) for PF4/PA complex specific IgG antibodies based on gold nanoparticles. Unlike most other assays, the initial immune reaction takes place in the liquid phase. The sensitivity of the assay has been adjusted with clinical samples aiming in the reliable detection of sera which are positive in a functional platelet activation assay. Sera from 60 patients with suspected HIT were investigated. LFIA identified correctly all samples (n=20) which were positive in a functional assay (HIPA) and an IgG specific ELISA. It correlated with ELISA, but false positive results were less frequent (7 samples were negative with LFIA and HIPA but positive with ELISA). The LFIA may be a suitable tool for the rapid exclusion of HIT within 10 min.

  18. Inappropriate use of commercial Antinuclear Antibody Testing in a community-based US hospital: a retrospective study

    Directory of Open Access Journals (Sweden)

    Abdul S. Mohammed

    2016-09-01

    Full Text Available Healthcare providers use antinuclear antibodies (ANAs to screen and diagnose patients with autoimmune diseases. In the recent years, commercial multiplex ANA kits have emerged as a convenient and fast diagnostic method. Diagnostic testing should follow sequenced algorithms: initial screen followed by specific antibody analysis. Second-level testing as an initial screen for autoimmune disease is inappropriate. We reviewed 68 patients with ANA comprehensive panels over a 6-month period from May 2015 to October 2015. We assessed appropriateness and estimated incurred losses from inappropriate testing. We found 92.6% (63 out of 68 of the ANA comprehensive panel results to be negative. Incurred losses from inappropriate ANA comprehensive panel testing were $66,000. Physicians should become familiar with ANA-sequenced diagnostic algorithms to avoid unnecessary higher level testing.

  19. Pregnancy does not affect HIV incidence test results obtained using the BED capture enzyme immunoassay or an antibody avidity assay

    National Research Council Canada - National Science Library

    Laeyendecker, Oliver; Church, Jessica D; Oliver, Amy E; Mwatha, Anthony; Owen, S Michele; Donnell, Deborah; Brookmeyer, Ron; Musoke, Philippa; Jackson, J Brooks; Guay, Laura; Nakabiito, Clemesia; Quinn, Thomas C; Eshleman, Susan H

    2010-01-01

    .... We used the BED capture immunoassay (BED) and an antibody avidity assay to test longitudinal samples from 51 HIV-infected Ugandan women infected with subtype A, C, D and intersubtype recombinant HIV who were enrolled in the HIVNET 012 trial...

  20. Thyroid Antibodies

    Science.gov (United States)

    ... Factor Antibody Iron Iron Tests JAK2 Mutation Kidney Stone Analysis Kidney Stone Risk Panel KRAS Mutation Lactate Lactate Dehydrogenase (LD) ... gain Fatigue Dry skin Hair loss Intolerance to cold Constipation A high level of thyroid hormone ( hyperthyroidism ) ...

  1. Testing iOS apps with HadoopUnit rapid distributed GUI testing

    CERN Document Server

    Tilley, Scott

    2014-01-01

    Smartphone users have come to expect high-quality apps. This has increased the importance of software testing in mobile software development. Unfortunately, testing apps-particularly the GUI-can be very time-consuming. Exercising every user interface element and verifying transitions between different views of the app under test quickly becomes problematic. For example, execution of iOS GUI test suites using Apple's UI Automation framework can take an hour or more if the app's interface is complicated. The longer it takes to run a test, the less frequently the test can be run, which in turn re

  2. Rapid antimicrobial susceptibility testing with electrokinetics enhanced biosensors for diagnosis of acute bacterial infections.

    Science.gov (United States)

    Liu, Tingting; Lu, Yi; Gau, Vincent; Liao, Joseph C; Wong, Pak Kin

    2014-11-01

    Rapid pathogen detection and antimicrobial susceptibility testing (AST) are required in diagnosis of acute bacterial infections to determine the appropriate antibiotic treatment. Molecular approaches for AST are often based on the detection of known antibiotic resistance genes. Phenotypic culture analysis requires several days from sample collection to result reporting. Toward rapid diagnosis of bacterial infection in non-traditional healthcare settings, we have developed a rapid AST approach that combines phenotypic culture of bacterial pathogens in physiological samples and electrochemical sensing of bacterial 16S rRNA. The assay determines the susceptibility of pathogens by detecting bacterial growth under various antibiotic conditions. AC electrokinetic fluid motion and Joule heating induced temperature elevation are optimized to enhance the sensor signal and minimize the matrix effect, which improve the overall sensitivity of the assay. The electrokinetics enhanced biosensor directly detects the bacterial pathogens in blood culture without prior purification. Rapid determination of the antibiotic resistance profile of Escherichia coli clinical isolates is demonstrated.

  3. Rapid whole monoclonal antibody analysis by mass spectrometry: An ultra scale-down study of the effect of harvesting by centrifugation on the post-translational modification profile.

    Science.gov (United States)

    Reid, C Q; Tait, A; Baldascini, H; Mohindra, A; Racher, A; Bilsborough, S; Smales, C M; Hoare, M

    2010-09-01

    With the trend towards the generation and production of increasing numbers of complex biopharmaceutical (protein based) products, there is an increased need and requirement to characterize both the product and production process in terms of robustness and reproducibility. This is of particular importance for products from mammalian cell culture which have large molecular structures and more often than not complex post-translational modifications (PTMs) that can impact the efficacy, stability and ultimately the safety of the final product. It is therefore vital to understand how the operating conditions of a bioprocess affect the distribution and make up of these PTMs to ensure a consistent quality and activity in the final product. Here we have characterized a typical bioprocess and determined (a) how the time of harvest from a mammalian cell culture and, (b) through the use of an ultra scale-down mimic how the nature of the primary recovery stages, affect the distribution and make up of the PTMs observed on a recombinant IgG(4) monoclonal antibody. In particular we describe the use of rapid whole antibody analysis by mass spectrometry to analyze simultaneously the changes that occur to the cleavage of heavy chain C-terminal lysine residues and the glycosylation pattern, as well as the presence of HL dimers. The time of harvest was found to have a large impact upon the range of glycosylation patterns observed, but not upon C-terminal lysine cleavage. The culture age had a profound impact on the ratio of different glycan moieties found on antibody molecules. The proportion of short glycans increased (e.g., (G0F)(2) 20-35%), with an associated decrease in the proportion of long glycans with culture age (e.g., (G2F)(2) 7-4%, and G1F/G2F from 15.2% to 7.8%). Ultra scale-down mimics showed that subsequent processing of these cultures did not change the post-translational modifications investigated, but did increase the proportion of half antibodies present in the

  4. Mobile Universal Lexicon Evaluation System (MULES) test: A new measure of rapid picture naming for concussion.

    Science.gov (United States)

    Cobbs, Lucy; Hasanaj, Lisena; Amorapanth, Prin; Rizzo, John-Ross; Nolan, Rachel; Serrano, Liliana; Raynowska, Jenelle; Rucker, Janet C; Jordan, Barry D; Galetta, Steven L; Balcer, Laura J

    2017-01-15

    This study introduces a rapid picture naming test, the Mobile Universal Lexicon Evaluation System (MULES), as a novel, vision-based performance measure for concussion screening. The MULES is a visual-verbal task that includes 54 original photographs of fruits, objects and animals. We piloted MULES in a cohort of volunteers to determine feasibility, ranges of picture naming responses, and the relation of MULES time scores to those of King-Devick (K-D), a rapid number naming test. A convenience sample (n=20, age 34±10) underwent MULES and K-D (spiral bound, iPad versions). Administration order was randomized; MULES tests were audio-recorded to provide objective data on temporal variability and ranges of picture naming responses. Scores for the best of two trials for all tests were 40-50s; average times required to name each MULES picture (0.72±0.14s) was greater than those needed for each K-D number ((spiral: 0.33±0.05s, iPad: 0.36±0.06s, 120 numbers), psystems than more commonly used rapid number naming tasks. Rapid picture naming may require additional processing devoted to color perception, object identification, and categorization. Both tests rely on initiation and sequencing of saccadic eye movements. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Validation of the Puumala virus rapid field test for bank voles in Germany.

    Science.gov (United States)

    Reil, D; Imholt, C; Rosenfeld, U M; Drewes, S; Fischer, S; Heuser, E; Petraityte-Burneikiene, R; Ulrich, R G; Jacob, J

    2017-02-01

    Puumala virus (PUUV) causes many human infections in large parts of Europe and can lead to mild to moderate disease. The bank vole (Myodes glareolus) is the only reservoir of PUUV in Central Europe. A commercial PUUV rapid field test for rodents was validated for bank-vole blood samples collected in two PUUV-endemic regions in Germany (North Rhine-Westphalia and Baden-Württemberg). A comparison of the results of the rapid field test and standard ELISAs indicated a test efficacy of 93-95%, largely independent of the origin of the antigens used in the ELISA. In ELISAs, reactivity for the German PUUV strain was higher compared to the Swedish strain but not compared to the Finnish strain, which was used for the rapid field test. In conclusion, the use of the rapid field test can facilitate short-term estimation of PUUV seroprevalence in bank-vole populations in Germany and can aid in assessing human PUUV infection risk.

  6. Clinical performance of the Multispot HIV-1/HIV-2 rapid test to correctly differentiate HIV-2 from HIV-1 infection in screening algorithms using third and fourth generation assays and to identify cross reactivity with the HIV-1 Western Blot.

    Science.gov (United States)

    Ramos, Eric M; Harb, Socorro; Dragavon, Joan; Coombs, Robert W

    2013-12-01

    An accurate and rapid serologic method to differentiate HIV-2 from HIV-1 infection is required since the confirmatory HIV-1 Western Blot (WB) may demonstrate cross-reactivity with HIV-2 antibodies. To evaluate the performance of the Bio-Rad Multispot HIV-1/HIV-2 rapid assay as a supplemental test to correctly identify HIV-2 infection and identify HIV-1 WB cross-reactivity with HIV-2 in clinical samples tested at an academic medical center. Between August 2008 and July 2012, clinical samples were screened for HIV using either 3rd- or 4th-generation HIV-1/2 antibody or combination antibody and HIV-1 p24 antigen assays, respectively. All repeatedly reactive samples were reflexed for Multispot rapid testing. Multispot HIV-2 and HIV-1 and HIV-2-reactive samples were further tested using an HIV-2 immunoblot assay and HIV-1 or HIV-2 RNA assays when possible. The HIV-1 WB was performed routinely for additional confirmation and to assess for HIV-2 antibody cross-reactivity. Of 46,061 samples screened, 890 (89.6%) of 993 repeatedly reactive samples were also Multispot-reactive: 882 for HIV-1; three for only HIV-2; and five for both HIV-1 and HIV-2. All three HIV-2-only Multispot-positives along with a single dually reactive HIV-1/2 Multispot-positive were also HIV-2 immunoblot-positive; the latter was HIV-1 RNA negative and HIV-2 RNA positive. The Multispot rapid test performed well as a supplemental test for HIV-1/2 diagnostic testing. Four new HIV-2 infections (0.45%) were identified from among 890 Multispot-reactive tests. The use of HIV-1 WB alone to confirm HIV-1/2 screening assays may underestimate the true prevalence of HIV-2 infection in the United States. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. Combination of SDS-PAGE and intact mass analysis for rapid determination of heterogeneities in monoclonal antibody therapeutics.

    Science.gov (United States)

    Yamada, Hideaki; Matsumura, Chiemi; Yamada, Keita; Teshima, Koichiro; Hiroshima, Takashi; Kinoshita, Mitsuhiro; Suzuki, Shigeo; Kakehi, Kazuaki

    2017-05-01

    mAbs are currently mainstream in biopharmaceuticals, and their market has been growing due to their high target specificity. Characterization of heterogeneities in mAbs is performed to secure their quality and safety by physicochemical analyses. However, they require time-consuming task, which often strain the resources of drug development in pharmaceuticals. Rapid and direct method to determine the heterogeneities should be a powerful tool for pharmaceutical analysis. Considering the advantages of electrophoresis and MS, this study addresses the combination of SDS-PAGE and intact mass analysis, which provides direct, rapid, and orthogonal determination of heterogeneities in mAb therapeutics. mAb therapeutics that migrated in SDS-PAGE were recovered from gel by treatment with SDC-containing buffer. Usage of SDC-containing buffer as extraction solvent and ethanol-based staining solution enhanced the recovery of intact IgG from SDS-PAGE gels. Recovery of mAbs reached more than 86% with 0.2% SD. The heterogeneities, especially N-glycan variants in the recovered mAb therapeutics, were clearly determined by intact mass analysis. We believe that the study is important in pharmaceuticals‧ perspective since orthogonal combination of gel electrophoresis and intact mass analysis should be pivotal role for rapid and precise characterization of mAbs. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Performance of rapid test in detection of HBsAg in frozen sera

    Directory of Open Access Journals (Sweden)

    Firat Zafer Mengeloglu

    2014-03-01

    Full Text Available Background — Hepatitis B is a widespread infectious disease throughout the world. Clinical and laboratory diagnosis of this infection is important. Rapid test of hepatitis B, known as cassette test, is a useful test that is easy to perform as well as it may have lack of sensitivity and specificity. Materials and Methods — Sera of a total of 55 patients were used for the study. All the sera that were tested for hepatitis B surface antigen (HBsAg using macro enzyme-linked immunosorbent assay (Macro ELISA were stored at -20°C for a maximum period of 3.5 years. The sera were thawed and tested again for HBsAg using the Nanosign rapid test kit (Bioland, South Korea for hepatitis B virus (HBV infection. Results — A total of 16 (29.1% sera revealed negative and the rest 39 were positive, meaning of a positivity rate of 70.9%. Rapid test revealed a very low positivity rate of 6.6% in sera with below 100 IU/ml level of HBsAg. In contrast, only two of the rest 40 sera with HBsAg levels above 100 units were negative, meaning of a positivity rate of 95.0% in high HBsAg level samples. A highly significant positive correlation was found between positivity levels and HBsAg levels (R=0.734, P<0.001, correlation is significant at the 0.01 level by 2-tailed analysis. We didn’t find any correlation between positivity and the period passed after freezing. Besides this, no significant difference was observed amongst the groups in terms of the time intervals of freezing. These findings suggest that the time passed after the first freeze of the sera didn’t cause any impact on the results of rapid tests. Conclusion — The findings of the present study suggest that the rapid test of HBV infection is reliable in sera with high levels of HBsAg, and the time passed after freezing of the sample doesn’t change the results of the tests. Besides this, a negative rapid test result doesn’t rule out the infection.

  9. Initial testing of a monoclonal antibody (IMC-A12) against IGF-1R by the Pediatric Preclinical Testing Program.

    Science.gov (United States)

    Houghton, Peter J; Morton, Christopher L; Gorlick, Richard; Kolb, E Anders; Keir, Stephen T; Reynolds, C Patrick; Kang, Min H; Maris, John M; Wu, Jianrong; Smith, Malcolm A

    2010-07-01

    Many childhood malignancies including sarcomas, neuroblastoma, and Wilms tumor show the presence of both, active, type-1-insulin-like growth factor receptor (IGF-1R), and the autocrine production of its ligands IGF-1/IGF-2. IMC-A12 is a fully human IgG1 antibody that prevents ligand binding to the IGF-1R. IMC-A12 was evaluated against the 23 cell lines of the Pediatric Preclinical Testing Program (PPTP) in vitro panel using 96 hr exposure at concentrations ranging from 0.01 nM to 0.1 microM. IMC-A12 was tested in vivo at a dose of 1 mg/mouse administered intraperitoneally twice weekly for 6 weeks. In vitro, IMC-A12-induced T/C values IMC-A12 induced significant differences in EFS distribution compared to control in 24 of 34 (71%) evaluable solid tumor xenografts. Using the PPTP "time to event" activity measure, IMC-A12 induced intermediate (n = 13) or high (n = 1) activity in 33 xenografts evaluable for this activity measure, including 6 of 6 rhabdomyosarcoma xenografts, 3 of 5 osteosarcoma xenografts, 2 of 5 neuroblastoma xenografts, and 1 of 5 Ewing sarcoma xenografts. The only objective response observed was observed in a rhabdomyosarcoma xenograft (Rh28) that achieved a maintained complete response. IMC-A12 demonstrated broad antitumor activity against the PPTP's in vivo solid tumor panels, with the activity primarily being tumor growth inhibition rather than tumor regression. IMC-A12 showed its greatest activity in vivo against the PPTP's rhabdomyosarcoma xenografts. Copyright 2010 Wiley-Liss, Inc.

  10. Rapid tests for the diagnosis of visceral leishmaniasis in patients with suspected disease

    Science.gov (United States)

    Boelaert, Marleen; Verdonck, Kristien; Menten, Joris; Sunyoto, Temmy; van Griensven, Johan; Chappuis, Francois; Rijal, Suman

    2014-01-01

    Background The diagnosis of visceral leishmaniasis (VL) in patients with fever and a large spleen relies on showing Leishmania parasites in tissue samples and on serological tests. Parasitological techniques are invasive, require sophisticated laboratories, consume time, or lack accuracy. Recently, rapid diagnostic tests that are easy to perform have become available. Objectives To determine the diagnostic accuracy of rapid tests for diagnosing VL in patients with suspected disease presenting at health services in endemic areas. Search methods We searched MEDLINE, EMBASE, LILACS, CIDG SR, CENTRAL, SCI-expanded, Medion, Arif, CCT, and the WHO trials register on 3 December 2013, without applying language or date limits. Selection criteria This review includes original, phase III, diagnostic accuracy studies of rapid tests in patients clinically suspected to have VL. As reference standards, we accepted: (1) direct smear or culture of spleen aspirate; (2) composite reference standard based on one or more of the following: parasitology, serology, or response to treatment; and (3) latent class analysis. Data collection and analysis Two review authors independently extracted data and assessed quality of included studies using the QUADAS-2 tool. Discrepancies were resolved by a third author. We carried out a meta-analysis to estimate sensitivity and specificity of rapid tests, using a bivariate normal model with a complementary log-log link function. We analysed each index test separately. As possible sources of heterogeneity, we explored: geographical area, commercial brand of index test, type of reference standard, disease prevalence, study size, and risk of bias (QUADAS-2). We also undertook a sensitivity analysis to assess the influence of imperfect reference standards. Main results Twenty-four studies containing information about five index tests (rK39 immunochromatographic test (ICT), KAtex latex agglutination test in urine, FAST agglutination test, rK26 ICT, and r

  11. The fourth generation AlereTM HIV Combo rapid test improves detection of acute infection in MTN-003 (VOICE) samples.

    Science.gov (United States)

    Livant, Edward; Heaps, Amy; Kelly, Cliff; Maharaj, Rashika; Samsunder, Natasha; Nhlangulela, Lindiwe; Karugaba, Patrick; Panchia, Ravindre; Marrazzo, Jeanne; Chirenje, Zvavahera Mike; Parikh, Urvi M

    2017-09-01

    Early and accurate detection of HIV is crucial when using pre-exposure prophylaxis (PrEP) for HIV prevention to avoid PrEP initiation in acutely infected individuals and to minimize the risk of drug resistance in individuals with breakthrough infection. To determine if fourth-generation antigen/antibody (Ag/Ab) rapid diagnostic tests (RDT) would have detected HIV infection earlier than the third-generation RDT used in MTN-003 (VOICE). 5029 VOICE participants were evaluated with third-generation Alere Determine™ HIV-1/2, OraQuick ADVANCE® Rapid HIV-1/2, Uni-Gold™ Recombigen® HIV-1/2 and Bio-Rad GS HIV-1/2+O EIA; and fourth-generation Alere Determine™ HIV-1/2 Ag/Ab Combo, Conformité Européene (CE)-Marked Alere™ HIV Combo and Bio-Rad HIV Combo Ag/Ab EIA. Multispot®, GS HIV-1 Western Blot (WB) and Geenius™ (Bio-Rad) were also evaluated. Of 57 antibody-negative pre-seroconversion plasma samples with HIV RNA >20 copies/mL identified, 16 (28%) were reactive by CE-Marked Alere™ HIV Combo (1 Ab; 9 Ag; 6 Ag/Ab reactive) and 4 (7%) by Alere Determine™ HIV-1/2 Ag/Ab Combo (2 Ab; 2 Ag; 0 Ag/Ab reactive) (p=0.0005). Multispot® confirmed only 1 of 16 acute infections while WB and Geenius™ confirmed none. GS HIV Combo Ag/Ab EIA identified 27 of 57 (47%) pre-seroconversion RNA-positive samples. In VOICE, 28% of infections missed by current third-generation RDT would have been identified with the use of CE-Marked Alere™ HIV Combo. Geenius™, Multispot® and WB were all insensitive (HIV RNA testing will be essential for efficiently identifying seroconverters on PrEP. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Rapid Bedside Inactivation of Ebola Virus for Safe Nucleic Acid Tests

    DEFF Research Database (Denmark)

    Rosenstierne, Maiken Worsøe; Karlberg, Helen; Bragstad, Karoline

    2016-01-01

    for nucleic acid extraction inactivates Ebola virus. A rapid bedside inactivation method for nucleic acid tests is obtained by simply adding Magna Pure lysis/binding buffer directly into vacuum blood collection EDTA tubes using a thin needle and syringe prior to sampling. The ready-to-use inactivation vacuum......Rapid bedside inactivation of Ebola virus would be a solution for the safety of medical and technical staff, risk containment, sample transport, and high-throughput or rapid diagnostic testing during an outbreak. We show that the commercially available Magna Pure lysis/binding buffer used...... tubes are stable for more than 4 months, and Ebola virus RNA is preserved in the Magna Pure lysis/binding buffer for at least 5 weeks independent of the storage temperature. We also show that Ebola virus RNA can be manually extracted from Magna Pure lysis/binding buffer-inactivated samples using...

  13. Rapid antigen detection test for respiratory syncytial virus diagnosis as a diagnostic tool,

    Directory of Open Access Journals (Sweden)

    Flávio da Silva Mesquita

    Full Text Available Abstract Objective: The aim of this study was to evaluate the QuickVue® RSV Test Kit (QUIDEL Corp, CA, USA as a screening tool for respiratory syncytial virus in children with acute respiratory disease in comparison with the indirect immunofluorescence assay as gold standard. In Brazil, rapid antigen detection tests for respiratory syncytial virus are not routinely utilized as a diagnostic tool, except for the diagnosis of dengue and influenza. Methods: The authors retrospectively analyzed 486 nasopharyngeal aspirate samples from children under age 5 with acute respiratory infection, between December 2013 and August 2014, the samples were analyzed by indirect immunofluorescence assay and QuickVue® RSV Test kit. Samples with discordant results were analyzed by real time PCR and nucleotide sequencing. Results: From 313 positive samples by immunofluorescence assays, 282 (90% were also positive by the rapid antigen detection test, two were positive only by rapid antigen detection test, 33 were positive only by immunofluorescence assays, and 171 were positive by both methods. The 35 samples with discordant results were analyzed by real time PCR; the two samples positive only by rapid antigen detection test and the five positive only by immunofluorescence assays were also positive by real time PCR. There was no relation between the negativity by QuickVue® RSV Test and viral load or specific strain. The QuickVue® RSV Test showed sensitivity of 90%, specificity of 98.8%, predictive positive value of 99.3%, and negative predictive value of 94.6%, with accuracy of 93.2% and agreement κ index of 0.85 in comparison to immunofluorescence assay. Conclusions: This study demonstrated that the QuickVue® RSV Test Kit can be effective in early detection of Respiratory syncytial virus in nasopharyngeal aspirate and is reliable for use as a diagnostic tool in pediatrics.

  14. Rapid antigen detection test for respiratory syncytial virus diagnosis as a diagnostic tool.

    Science.gov (United States)

    Mesquita, Flávio da Silva; Oliveira, Danielle Bruna Leal de; Crema, Daniela; Pinez, Célia Miranda Nunes; Colmanetti, Thaís Cristina; Thomazelli, Luciano Matsumia; Gilio, Alfredo Elias; Vieira, Sandra Elisabeth; Martinez, Marina Baquerizo; Botosso, Viviane Fongaro; Durigon, Edison Luiz

    The aim of this study was to evaluate the QuickVue® RSV Test Kit (QUIDEL Corp, CA, USA) as a screening tool for respiratory syncytial virus in children with acute respiratory disease in comparison with the indirect immunofluorescence assay as gold standard. In Brazil, rapid antigen detection tests for respiratory syncytial virus are not routinely utilized as a diagnostic tool, except for the diagnosis of dengue and influenza. The authors retrospectively analyzed 486 nasopharyngeal aspirate samples from children under age 5 with acute respiratory infection, between December 2013 and August 2014, the samples were analyzed by indirect immunofluorescence assay and QuickVue® RSV Test kit. Samples with discordant results were analyzed by real time PCR and nucleotide sequencing. From 313 positive samples by immunofluorescence assays, 282 (90%) were also positive by the rapid antigen detection test, two were positive only by rapid antigen detection test, 33 were positive only by immunofluorescence assays, and 171 were positive by both methods. The 35 samples with discordant results were analyzed by real time PCR; the two samples positive only by rapid antigen detection test and the five positive only by immunofluorescence assays were also positive by real time PCR. There was no relation between the negativity by QuickVue® RSV Test and viral load or specific strain. The QuickVue® RSV Test showed sensitivity of 90%, specificity of 98.8%, predictive positive value of 99.3%, and negative predictive value of 94.6%, with accuracy of 93.2% and agreement κ index of 0.85 in comparison to immunofluorescence assay. This study demonstrated that the QuickVue® RSV Test Kit can be effective in early detection of Respiratory syncytial virus in nasopharyngeal aspirate and is reliable for use as a diagnostic tool in pediatrics. Copyright © 2016 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  15. Comparison of a New and Rapid Method: Brucella Coombs Gel Test With Other Diagnostic Tests.

    Science.gov (United States)

    Kalem, Fatma; Ergün, Ayşe Gül; Durmaz, Süleyman; Doğan, Metin; Ertuğrul, Ömür; Gündem, Seval

    2016-09-01

    The aim of this study was to detect reliability of Brucella Coombs gel test (BCGT) by comparing with with ELISA (IgG + IgM), Standard agglutination test, and Brucella immunocapture agglutination methods in serological diagnosis of brucellosis. Brucella Coombs gel test (BCGT), Brucella ELISA (IgG + IgM), Standard agglutination test, and Brucella immunocapture agglutination tests of 78 patients with presumptive diagnosis of brucellosis which were sent to Microbiology Laboratory of Konya Numune Hospital from various regions of Konya were studied. Of 78 patients with ELISA IgG and IgM, STA, BICA and BCGT; 26, 21, 10, 12 and 12 were positive. When compared with BICA, the sensitivity and specifity of BCGT were 100% and 100%, respectively. According to results BCGT can be used as a diagnostic test in routine laboratories after more comprehensive studies in control groups and patients. © 2016 Wiley Periodicals, Inc.

  16. Investigating Recent Testing among MSM: Results from Community-Based HIV Rapid Testing Attendees in France

    Directory of Open Access Journals (Sweden)

    Nicolas Lorente

    2013-01-01

    Full Text Available Background. We aimed to identify factors associated with recent HIV testing in MSM who attended two experimental community-based and nonmedicalized voluntary counselling and testing programmes (CB-VCT targeting MSM in France. Methods. This analysis was based on data collected in 2009–2011 through a self-administered pretesting questionnaire. An index measuring the level of participants’ sexual orientation disclosure was built: the higher the index, the greater the disclosure. Factors associated with recent HIV testing (last test ≤ 1 year were identified using a multivariate logistic regression model adjusted for the CB-VCT programme of enrolment. Results. 716 MSM provided data on testing history. Overall, 49% were recently tested for HIV and 51% were not. Recently tested MSM had a higher homosexuality disclosure index (adjusted OR [95% confidence interval]: aOR = 1.2 [1.1–1.4], reported more inconsistent condom use during anal sex with men (aOR = 1.6 [1.2–2.1], and were less likely to have sex under the influence of club drugs (aOR = 0.6 [0.4–1.0]. Conclusion. New testing strategies should focus on those who live their homosexuality relatively secretly and those who use club drugs before sex. Governments should develop policies which encourage improved social acceptance of homosexuality as concealment of sexual orientation represents a major barrier to testing.

  17. Immunochromatographic Lateral-flow test strip for the rapid detection of added bovine rennet whey in milk and milk powder

    NARCIS (Netherlands)

    Martin-Hernandez, C.; Munoz, M.; Daury, C.; Weymuth, H.; Kemmers-Voncken, A.; Corbation, V.; Toribo, T.; Bremer, M.G.E.G.

    2009-01-01

    An immunochromatographic lateral-flow test dipstick test was developed for the fast detection of bovine rennet whey in liquid milk and milk powder. The test is based on the binding of casein glycomacropeptide (cGMP) by two specific anti-bovine ¿-casein monoclonal antibodies and has a visual

  18. One-step antibody immobilization-based rapid and highly-sensitive sandwich ELISA procedure for potential in vitro diagnostics

    Science.gov (United States)

    Vashist, Sandeep Kumar; Marion Schneider, E.; Lam, Edmond; Hrapovic, Sabahudin; Luong, John H. T.

    2014-01-01

    An improved enzyme-linked immunosorbent (ELISA) assay using one-step antibody immobilization has been developed for the detection of human fetuin A (HFA), a specific biomarker for atherosclerosis and hepatocellular carcinoma. The anti-HFA formed a stable complex with 3-aminopropyltriethoxysilane (APTES) by ionic and hydrophobic interactions. The complex adsorbed on microtiter plates exhibited a detection range of 4.9 pg mL−1 to 20 ng mL−1 HFA, with a limit of detection of 7 pg mL−1. Furthermore, an analytical sensitivity of 10 pg mL−1 was achieved, representing a 51-fold increase in sensitivity over the commercial sandwich ELISA kit. The results obtained for HFA spiked in diluted human whole blood and plasma showed the same precision as the commercial kit. When stored at 4°C in 0.1 M phosphate-buffered saline (PBS, pH 7.4), the anti-HFA bound microtiter plates displayed no significant decrease in their functional activity after two months. The new ELISA procedure was extended for the detection of C-reactive protein, human albumin and human lipocalin-2 with excellent analytical performance. PMID:24638258

  19. Rapid prototyping of centrifugal microfluidic modules for point of care blood testing

    CSIR Research Space (South Africa)

    Madzivhandila, Phophi

    2016-11-01

    Full Text Available We present modular centrifugal microfluidic devices that enable a series of blood tests to be performed towards a full blood count. The modular approach allows for rapid prototyping of device components in a generic format to complete different...

  20. Cost-effectiveness of rapid susceptibility testing against second-line drugs for tuberculosis

    NARCIS (Netherlands)

    Dowdy, D. W.; van't Hoog, A.; Shah, M.; Cobelens, F.

    2014-01-01

    Drug susceptibility testing (DST) against second-line tuberculosis drugs (SLDs) is essential for improving outcomes among multidrug-resistant (MDR-) and extensively drug-resistant tuberculosis (XDR-TB) cases. To evaluate the potential cost-effectiveness of rapid DST for SLDs. We constructed a

  1. APTEC: aptamer-tethered enzyme capture as a novel rapid diagnostic test for malaria.

    Science.gov (United States)

    Dirkzwager, Roderick M; Kinghorn, Andrew B; Richards, Jack S; Tanner, Julian A

    2015-03-18

    We report the rapid diagnosis of malaria by aptamer-tethered enzyme capture (APTEC) whereby an aptamer captures biomarker Plasmodium falciparum lactate dehydrogenase (PfLDH) then activity is measured colorimetrically. The robust test was sensitive (limit of detection = 4.9 ng mL(-1)) and could reliably diagnose malaria in clinical blood samples.

  2. A cluster randomised trial introducing rapid diagnostic tests into registered drug shops in Uganda

    DEFF Research Database (Denmark)

    Mbonye, Anthony K; Magnussen, Pascal; Lal, Sham

    2015-01-01

    the impact of introducing rapid diagnostic tests for malaria (mRDTs) in registered drug shops in Uganda, with the aim to increase appropriate treatment of malaria with artemisinin-based combination therapy (ACT) in patients seeking treatment for fever in drug shops. METHODS: A cluster-randomized trial...

  3. [Introduction of rapid syphilis and HIV testing in prenatal care in Colombia: qualitative analysis].

    Science.gov (United States)

    Ochoa-Manjarrés, María Teresa; Gaitán-Duarte, Hernando Guillermo; Caicedo, Sidia; Gómez, Berta; Pérez, Freddy

    2016-12-01

    Interpret perceptions of Colombian health professionals concerning factors that obstruct and facilitate the introduction of rapid syphilis and HIV testing in prenatal care services. A qualitative study based on semi-structured interviews was carried out. A convenience sample was selected with 37 participants, who included health professionals involved in prenatal care services, programs for pregnant women, clinical laboratories, and directors of health care units or centers, as well as representatives from regional departments and the Ministry of Health. Colombia does not do widespread screening with rapid syphilis and HIV tests in prenatal care. The professionals interviewed stated they did not have prior experience in the use of rapid tests-except for laboratory staff-or in the course of action in response to a positive result. The insurance system hinders access to timely diagnosis and treatment. Health authorities perceive a need to review existing standards, strengthen the first level of care, and promote comprehensive prenatal care starting with contracts between insurers and health service institutional providers. Participants recommended staff training and integration between health-policymaking and academic entities for updating training programs. The market approach and the characteristics of the Colombian health system constitute the main barriers to implementation of rapid testing as a strategy for elimination of mother-to-child transmission of syphilis and HIV. Measures identified include making changes in contracts between insurers and health service institutional providers, adapting the timing and duration of prenatal care procedures, and training physicians and nurses involved in prenatal care.

  4. Comparison of blood smear microscopy to a rapid diagnostic test for ...

    African Journals Online (AJOL)

    Objective: To compare the diagnostic performance of microscopy using Giemsastained thick and thin blood smears to a rapid malaria dipstick test (RDT) in detecting P. falciparum malaria in Kenyan school children. Design: Randomised, controlled feeding intervention trial from 1998-2001. Setting: Rural Embu district, Kenya ...

  5. Rapid antimicrobial susceptibility testing of clinical isolates by digital time-lapse microscopy

    DEFF Research Database (Denmark)

    Fredborg, M; Rosenvinge, F S; Spillum, E

    2015-01-01

    Rapid antimicrobial susceptibility testing (AST) is essential for early and appropriate therapy. Methods with short detection time enabling same-day treatment optimisation are highly favourable. In this study, we evaluated the potential of a digital time-lapse microscope system, the oCelloScope s...

  6. Rapid catalase supplemental test for identification of members of the family Enterobacteriaceae.

    OpenAIRE

    Chester, B; Moskowitz, L B

    1987-01-01

    A simple, rapid, semiquantitative slide catalase test useful for differentiating members of the family Enterobacteriaceae is described. Judging by the time required for appearance of oxygen bubbles in 3% hydrogen peroxide, the immediate catalase reactors were Yersinia, Serratia, Proteus, Morganella, Providencia, Cedecea, and Hafnia spp. The delayed catalase reactors were Escherichia, Shigella, Klebsiella, Enterobacter, Salmonella, Citrobacter, Edwardsiella, Kluyvera, and Tatumella spp. This i...

  7. The impact of introducing malaria rapid diagnostic tests on fever case management

    DEFF Research Database (Denmark)

    Bruxvoort, Katia J; Leurent, Baptiste; Chandler, Clare I R

    2017-01-01

    Since 2010, the World Health Organization has been recommending that all suspected cases of malaria be confirmed with parasite-based diagnosis before treatment. These guidelines represent a paradigm shift away from presumptive antimalarial treatment of fever. Malaria rapid diagnostic tests (mRDTs...

  8. Rapid Generation and Testing of a Lassa Fever Vaccine Using VaxCelerate Platform

    Science.gov (United States)

    2014-08-28

    981959472 222357 In silico analysis of Mtb HSP70 subdomains for modification University of Washington 1100 NE 45th Street, Suite 300 Seattle WA 981054696...222357 In silico analysis of Mtb HSP70 subdomains for modification 1 a. 1 a. 6 Grant Title: Rapid Generation and Testing of a Lassa Fever Vaccine...14 Figure 6: Linear Structure of the Mtb HSP70 Variants

  9. The role of rapid diagnostic tests in managing adults with pneumonia in low-resource settings

    Directory of Open Access Journals (Sweden)

    Stephen J Aston

    2014-06-01

    Full Text Available In well-resourced settings the systematic use of rapid diagnostics tests (e.g. pneumococcal urinary antigen test that define the causal pathogen to direct therapy has not resulted in significantly improved outcomes in adults with pneumonia. The management of pneumonia in many low-resource settings is complicated by a substantial burden of tuberculosis and HIV-associated opportunistic infections, in addition to the usual spectrum of pathogens seen in well-resourced settings. Clinical features alone do not reliably distinguish between these different aetiologies and physicians often have to treat empirically. Given the limitations in diagnostic laboratory capability present in most low-resource settings, rapid and point-of-care diagnostic tests could become valuable tools to guide treatment decisions. Pneumococcal and Legionella urinary antigen tests are specific and moderately sensitive, but their utility in low-resource settings is uncertain. The Xpert MTB/RIF (Cepheid, USA platform and rapid assays for urinary lipoarabinomannan can substantially speed up tuberculosis diagnosis; the current challenge is to translate this into earlier treatment and hopefully improve patient outcome. In HIV-infected patients, 1-3-β-D-glucan is a serum marker of Pneumocystis jirovecii infection with excellent sensitivity. Further studies are needed to assess the clinical utility and cost-effectiveness of these rapid diagnostic assays when they are incorporated into treatment algorithms.

  10. Human Plasmodium knowlesi infection detected by rapid diagnostic tests for malaria

    NARCIS (Netherlands)

    J.J. van Hellemond (Jaap); M. Rutten (Martine); R. Koelewijn (Rob); A.M. Zeeman (Anne Marie); J. Verweij (Jaap); P.J. Wismans (Pieter); C.H. Kocken (Clemens); P.J.J. van Genderen (Perry)

    2009-01-01

    textabstractWe describe a PCR-confirmed case of Plasmodium knowlesi infection with a high parasitemia level and clinical signs of severe malaria in a migrant worker from Malaysian Borneo in the Netherlands. Investigations showed that commercially available rapid antigen tests for detection of human

  11. Immunoblotting as a confirmatory test for antimitochondrial antibodies in primary biliary cirrhosis.

    OpenAIRE

    Provenzano, G; Diquattro, O; Craxì, A; Almasio, P; Pinzello, G; Marino, L; Fiorentino, G; Rinaldi, F; Pagliaro, L

    1993-01-01

    Primary biliary cirrhosis is characterised by the presence of antimitochondrial antibodies which are directed against components of mitochondrial dehydrogenase complexes. The specificity of antimitochondrial antibodies for primary biliary cirrhosis as detected by immunoblotting was investigated. Commercially available preparations of pyruvate and oxo-glutarate dehydrogenases and beef-heart mitochondria were used as source of antigens. Sera from 47 primary biliary cirrhosis patients (46 of who...

  12. Factors associated with refusal of rapid HIV testing in an emergency department.

    Science.gov (United States)

    Pisculli, Mary L; Reichmann, William M; Losina, Elena; Donnell-Fink, Laurel A; Arbelaez, Christian; Katz, Jeffrey N; Walensky, Rochelle P

    2011-05-01

    HIV screening studies in the emergency department (ED) have demonstrated rates of HIV test refusal ranging from 40-67%. This study aimed to determine the factors associated with refusal to undergo routine rapid HIV testing in an academic ED in Boston. HIV counselors offered routine testing to 1,959 patients; almost one-third of patients (29%) refused. Data from a self-administered survey were used to determine independent correlates of HIV testing refusal. In multivariate analysis, women and patients with annual household incomes of $50,000 or more were more likely to refuse testing, as were those who reported not engaging in HIV risk behaviors, those previously HIV tested and those who did not perceive a need for testing. Enrollment during morning hours was also associated with an increased risk of refusal. Increased educational efforts to convey the rationale and benefits of universal screening may improve testing uptake among these groups.

  13. Rapid point-of-care HIV testing in pregnant women: a systematic review and meta-analysis.

    Science.gov (United States)

    Pai, Nitika Pant; Tulsky, Jacqueline Peterson; Cohan, Deborah; Colford, John M; Reingold, Arthur L

    2007-02-01

    Rapid, point-of-care human immunodeficiency virus (HIV) testing has the potential to enhance strategies to prevent mother-to-child transmission (MTCT) of HIV infection. Rapid tests need minimal laboratory infrastructure and can be performed by health workers with minimal training. In our systematic review and meta-analysis, we aimed to summarize the overall diagnostic accuracy of rapid HIV tests in pregnancy, and outcomes such as acceptability, patient preference, feasibility and impact of rapid testing. We searched four major databases, identified and screened 1377 citations, and included 17 studies that met our eligibility criteria. Analyses of these studies suggested that the overall sensitivity and specificity of blood-based rapid tests was high compared with oral rapid tests. A two-step testing strategy, particularly parallel testing, was found to be superior to single-test strategy in labour and delivery settings. Acceptability of rapid tests and patient preference was variable across studies. Overall, rapid HIV testing was highly accurate compared with conventional tests and offer a clear advantage of enabling the implementation of timely interventions to reduce MTCT of HIV. To improve diagnostic accuracy and to reduce false-positive results, it may be necessary to use two rapid tests during labour and delivery.

  14. Development of VHH Antibodies against Dengue Virus Type 2 NS1 and Comparison with Monoclonal Antibodies for Use in Immunological Diagnosis

    Science.gov (United States)

    Fatima, Aneela; Wang, Haiying; Kang, Keren; Xia, Liliang; Wang, Ying; Ye, Wei; Wang, Jufang; Wang, Xiaoning

    2014-01-01

    The possibility of using variable domain heavy-chain antibodies (VHH antibodies) as diagnostic tools for dengue virus (DENV) type 2 NS1 protein was investigated and compared with the use of conventional monoclonal antibodies. After successful expression of DENV type 2 NS1 protein, the genes of VHH antibodies against NS1 protein were biopanned from a non-immune llama library by phage display. VHH antibodies were then expressed and purified from Escherichia coli. Simultaneously, monoclonal antibodies were obtained by the conventional route. Sequence analysis of the VHH antibodies revealed novel and long complementarity determining regions 3 (CDR3). Epitope mapping was performed via a phage display peptide library using purified VHH and monoclonal antibodies as targets. Interestingly, the same region of NS1, which comprises amino acids 224HWPKPHTLW232, was conserved for both kinds of antibodies displaying the consensus motif histidine-tryptophan-tryptophan or tryptophan-proline-tryptophan. The two types of antibodies were used to prepare rapid diagnostic kits based on immunochromatographic assay. The VHH antibody immobilized rapid diagnostic kit showed better sensitivity and specificity than the monoclonal antibody immobilized rapid diagnostic kit, which might be due to the long CDR3 regions of the VHH antibodies and their ability to bind to the pocket and cleft of the targeted antigen. This demonstrates that VHH antibodies are likely to be an option for developing point-of-care tests against DENV infection. PMID:24751715

  15. Quantum dot-based lateral-flow immunoassay for rapid detection of rhein using specific egg yolk antibodies.

    Science.gov (United States)

    Zhang, Yue; Kong, Hui; Liu, Xiaoman; Cheng, Jinjun; Zhang, Meiling; Wang, Yongzhi; Lu, Fang; Qu, Huihua; Zhao, Yan

    2017-10-16

    The lateral-flow immunoassays based on novel fluorescent labels have been receiving increasing attention. Here, we developed a rapid, quantitative, lateral-flow immunoassay for rapid and accurate detection of rhein (RHE). The competitive immunoassay used anti-RHE IgY (immunoglobulin of yolk) probe conjugated with QDs as reporter. Our results showed that the immunochromatographic strip can be applied for qualitative and quantitative analysis of RHE in samples. For quantitative analysis, the strips were scanned by a membrane-strip reader, and a detection curve (y = -0.128ln(x) + 1.7627, correlation coefficient = 0.9792) representing the averages of the scanned data was obtained. The detection range was 80-5000 ng mL -1 and the qualitative-detection limit for RHE was 98.2 ng mL -1 . To our knowledge, this is the first report of the quantitative detection of a natural product by QDs-IgY immunochromatography, which creates a new strategy to detect the harmful or index component of TCM and may be applied as a supplement or alternative to instrument detection.

  16. Evaluation of a rapid and simple fourth-generation HIV screening assay for qualitative detection of HIV p24 antigen and/or antibodies to HIV-1 and HIV-2.

    Science.gov (United States)

    Beelaert, G; Fransen, K

    2010-09-01

    The performance was assessed of a new, rapid, visual and qualitative immunoassay for the detection of HIV p24 antigen (Ag) and antibodies (Ab) to HIV-1 and HIV-2. Characterised serum or plasma specimens from patients diagnosed with HIV infection were tested: 179 samples of known Ab-positive patients harbouring different subtypes of HIV-1 (n=154) and HIV-2 (n=25) and 200 samples from individuals not infected with HIV. The assay's Ag sensitivity was assessed by testing HIV seroconversion panels (n=10) and primary HIV infection specimens (n=57). In addition, the influence of the genetic variability of HIV-1 on Ag detection was evaluated using dilutions of culture supernatants infected with different subtypes (n=50). The performance of the rapid test was compared to a "gold standard" testing algorithm with the use of a single Ag ELISA and with the Vironostika((R)) HIV Uni-Form II Ag/Ab test, a fourth-generation ELISA. The new assay, the Determine HIV-1/2 Combo demonstrated 100% (98.2-100.0) Ab specificity (200/200) and 100% (98.0-100.0) Ab sensitivity (179/179). In these samples, the observed Ag sensitivity was 86.6% (58/67) with the Determine HIV-1/2 Combo test and 92.5% (62/67) with the Vironostika compared to the reference single Ag ELISA. The assay could not detect Ag in one group O, one subtype F and two subtype H cell supernatant isolates. None of the HIV-2 Ag could be detected. Copyright 2010 Elsevier B.V. All rights reserved.

  17. Detection of Early Sero-Conversion HIV Infection Using the INSTITM HIV-1 Antibody Point-of-Care Test

    OpenAIRE

    Cook, Darrel; Gilbert, Mark; DiFrancesco, Lillo; Krajden, Mel

    2010-01-01

    We compared the INSTITM HIV-1 Antibody Point-of-Care (POC) Test to laboratory-based tests for detection of early sero-conversion (i.e. acute) HIV infections. Fifty-three (53) individuals with early HIV infection, (i.e. 3rd generation anti-HIV EIA non-reactive or reactive, HIV-1 Western Blot non-reactive or indeterminate and HIV-1 p24 antigen reactive) were tested by INSTITM. The INSTITM test was reactive for 34/49 (sensitivity 69.4%; 95% confidence interval 54.6-81.8%) early-infected individu...

  18. Evaluation of dengue NS1 antigen rapid tests and ELISA kits using clinical samples.

    Directory of Open Access Journals (Sweden)

    Subhamoy Pal

    Full Text Available Early diagnosis of dengue virus (DENV infection can improve clinical outcomes by ensuring close follow-up, initiating appropriate supportive therapies and raising awareness to the potential of hemorrhage or shock. Non-structural glycoprotein-1 (NS1 has proven to be a useful biomarker for early diagnosis of dengue. A number of rapid diagnostic tests (RDTs and enzyme-linked immunosorbent assays (ELISAs targeting NS1 antigen (Ag are now commercially available. Here we evaluated these tests using a well-characterized panel of clinical samples to determine their effectiveness for early diagnosis.Retrospective samples from South America were used to evaluate the following tests: (i "Dengue NS1 Ag STRIP" and (ii "Platelia Dengue NS1 Ag ELISA" (Bio-Rad, France, (iii "Dengue NS1 Detect Rapid Test (1st Generation" and (iv "DENV Detect NS1 ELISA" (InBios International, United States, (v "Panbio Dengue Early Rapid (1st generation" (vi "Panbio Dengue Early ELISA (2nd generation" and (vii "SD Bioline Dengue NS1 Ag Rapid Test" (Alere, United States. Overall, the sensitivity of the RDTs ranged from 71.9%-79.1% while the sensitivity of the ELISAs varied between 85.6-95.9%, using virus isolation as the reference method. Most tests had lower sensitivity for DENV-4 relative to the other three serotypes, were less sensitive in detecting secondary infections, and appeared to be most sensitive on Day 3-4 post symptom onset. The specificity of all evaluated tests ranged from 95%-100%.ELISAs had greater overall sensitivity than RDTs. In conjunction with other parameters, the performance data can help determine which dengue diagnostics should be used during the first few days of illness, when the patients are most likely to present to a clinic seeking care.

  19. Application of non-structural protein antibody tests in substantiating freedom from foot-and-mouth disease virus infection after emergency vaccination of cattle

    DEFF Research Database (Denmark)

    Paton, D.J.; de Clercq, K.; Greiner, Matthias

    2006-01-01

    There has been much debate about the use of the so-called "vaccinate-to-live" policy for the control of foot-and-mouth disease (FMD) in Europe, according to which, spread of the FMD virus (FMDV) from future outbreaks could be controlled by a short period of "emergency" vaccination of surrounding...... herds, reducing the need for large-scale pre-emptive culling of at-risk animals. Since vaccinated animals may become subclinically infected with FMDV following challenge exposure, it is necessary to either remove all vaccinates (vaccinate-to-kill) or to detect and remove vaccinates in which virus...... is circulating or has established persistent infections (vaccinate-to-live), in order to rapidly regain the most favoured trading status of FMD-free without vaccination. The latter approach can be supported by testing vaccinated animals for the presence of antibodies to certain non-structural proteins (NSP...

  20. Economic analysis of rapid multiplex polymerase chain reaction testing for meningitis/encephalitis in pediatric patients.

    Science.gov (United States)

    Duff, Steve; Hasbun, Rodrigo; Ginocchio, Christine C; Balada-Llasat, Joan-Miquel; Zimmer, Louise; Bozzette, Samuel A

    2018-01-10

    We assessed the possible economic impact of a rapid test in pediatric patients with suspected community-acquired meningitis/encephalitis. Modeling simulated diagnosis, clinical decisions, resource use/costs of standard of care (SOC) and two cerebrospinal fluid testing strategies using FilmArray ® (FA), a US FDA-cleared system that provides results in approximately 1 h. Pathogens detected by FA caused approximately 75% of cases, 97% of which would be accurately diagnosed with FA.  Mean cost/case ranged from $17,599 to $22,025.  Syndromic testing is less expensive than SOC. Testing all suspected cases yielded greater savings ($3481/case) than testing only those with abnormal cerebrospinal fluid ($2157/case). Greater economic benefits are achievable with syndromic testing of all cases, rather than SOC or targeted syndromic testing.

  1. Diagnosing dengue virus infection: rapid tests and the role of micro/nanotechnologies.

    Science.gov (United States)

    Zhang, Bei; Salieb-Beugelaar, Georgette B; Nigo, Maurice Mutro; Weidmann, Manfred; Hunziker, Patrick

    2015-10-01

    Due to the progressive spread of the dengue virus and a rising incidence of dengue disease, its rapid diagnosis is important for developing countries and of increasing relevance for countries in temperate climates. Recent advances in bioelectronics, micro- and nanofabrication technologies have led to new miniaturized point-of-care devices and analytical platforms suited for rapid detection of infections. Starting from the available tests for dengue diagnosis, this review examines emerging rapid, micro/nanotechnologies-based tools, including label-free biosensor methods, microarray and microfluidic platforms, which hold significant potential, but still need further development and evaluation. The epidemiological and clinical setting as key determinants for selecting the best analytical strategy in patients presenting with fever is then discussed. This review is aimed at the clinicians and microbiologists to deepen understanding and enhance application of dengue diagnostics, and also serves as knowledge base for researchers and test developers to overcome the challenges posed by this disease. Dengue disease remains a significant problem in many developing countries. Unfortunately rapid diagnosis with easy and low cost tests for this disease is currently still not realized. In this comprehensive review, the authors highlighted recent advances in nanotechnology which would enable development in this field, which would result in beneficial outcomes to the population. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. Rapid Immunization Scheme for Spouses of Individuals Estabilished as Hepatitis B Carriers during Premarital Tests

    Directory of Open Access Journals (Sweden)

    Selma Tosun

    2012-01-01

    Full Text Available Background. The aim of this study was to monitor the cases identified as hepatitis B carriers during premarital tests, to vaccinate their prospective spouses with a rapid vaccination scheme, and to compare the anti-HBs responses with the traditional vaccination scheme. Methods. Blood samples of 1250 couple spouses were tested for HBsAg and anti-HBs. HBsAg positive cases' fiancées which were found HBV negative were administered a rapid three-dose vaccination scheme on days 0, 7, and 21. Forty controls with similar age and gender were also were administered three doses of the same vaccine. Results. Out of 1250 cases (625 couples, 46 (3.6% were HBsAg positive, and 40 of them aged between 18 and 39 were admitted to the rapid vaccination program. Conclusion. Upon determination of HBsAg positivity in premarital tests, a rapid vaccination program provides early protection, but the 6th and 12th month vaccinations are also required. Anti-HBs response should be monitored.

  3. Viral hepatitis and rapid diagnostic test based screening for HBsAg in HIV-infected patients in rural Tanzania.

    Science.gov (United States)

    Franzeck, Fabian C; Ngwale, Ramadhani; Msongole, Bernadeta; Hamisi, Marian; Abdul, Omary; Henning, Lars; Letang, Emilio; Mwaigomole, Geoffrey; Battegay, Manuel; Hatz, Christoph; Tanner, Marcel

    2013-01-01

    Co-infection with hepatitis B virus (HBV) is highly prevalent in people living with HIV in Sub-Saharan Africa. Screening for HBV surface antigen (HBsAg) before initiation of combination antiretroviral therapy (cART) is recommended. However, it is not part of diagnostic routines in HIV programs in many resource-limited countries although patients could benefit from optimized antiretroviral therapy covering both infections. Screening could be facilitated by rapid diagnostic tests for HBsAg. Operating experience with these point of care devices in HIV-positive patients in Sub-Saharan Africa is largely lacking. We determined the prevalence of HBV and Hepatitis C virus (HCV) infection as well as the diagnostic accuracy of the rapid test device Determine HBsAg in an HIV cohort in rural Tanzania. Prospectively collected blood samples from adult, HIV-1 positive and antiretroviral treatment-naïve patients in the Kilombero and Ulanga antiretroviral cohort (KIULARCO) in rural Tanzania were analyzed at the point of care with Determine HBsAg, a reference HBsAg EIA and an anti-HCV EIA. Samples of 272 patients were included. Median age was 38 years (interquartile range [IQR] 32-47), 169/272 (63%) subjects were females and median CD4+ count was 250 cells/µL (IQR 97-439). HBsAg was detected in 25/272 (9.2%, 95% confidence interval [CI] 6.2-13.0%) subjects. Of these, 7/25 (28%) were positive for HBeAg. Sensitivity of Determine HBsAg was rated at 96% (95% CI 82.8-99.6%) and specificity at 100% (95% CI, 98.9-100%). Antibodies to HCV (anti-HCV) were found in 10/272 (3.7%, 95% CI 2.0-6.4%) of patients. This study reports a high prevalence of HBV in HIV-positive patients in a rural Tanzanian setting. The rapid diagnostic test Determine HBsAg is an accurate assay for screening for HBsAg in HIV-1 infected patients at the point of care and may further help to guide cART in Sub-Saharan Africa.

  4. Viral hepatitis and rapid diagnostic test based screening for HBsAg in HIV-infected patients in rural Tanzania.

    Directory of Open Access Journals (Sweden)

    Fabian C Franzeck

    Full Text Available BACKGROUND: Co-infection with hepatitis B virus (HBV is highly prevalent in people living with HIV in Sub-Saharan Africa. Screening for HBV surface antigen (HBsAg before initiation of combination antiretroviral therapy (cART is recommended. However, it is not part of diagnostic routines in HIV programs in many resource-limited countries although patients could benefit from optimized antiretroviral therapy covering both infections. Screening could be facilitated by rapid diagnostic tests for HBsAg. Operating experience with these point of care devices in HIV-positive patients in Sub-Saharan Africa is largely lacking. We determined the prevalence of HBV and Hepatitis C virus (HCV infection as well as the diagnostic accuracy of the rapid test device Determine HBsAg in an HIV cohort in rural Tanzania. METHODS: Prospectively collected blood samples from adult, HIV-1 positive and antiretroviral treatment-naïve patients in the Kilombero and Ulanga antiretroviral cohort (KIULARCO in rural Tanzania were analyzed at the point of care with Determine HBsAg, a reference HBsAg EIA and an anti-HCV EIA. RESULTS: Samples of 272 patients were included. Median age was 38 years (interquartile range [IQR] 32-47, 169/272 (63% subjects were females and median CD4+ count was 250 cells/µL (IQR 97-439. HBsAg was detected in 25/272 (9.2%, 95% confidence interval [CI] 6.2-13.0% subjects. Of these, 7/25 (28% were positive for HBeAg. Sensitivity of Determine HBsAg was rated at 96% (95% CI 82.8-99.6% and specificity at 100% (95% CI, 98.9-100%. Antibodies to HCV (anti-HCV were found in 10/272 (3.7%, 95% CI 2.0-6.4% of patients. CONCLUSION: This study reports a high prevalence of HBV in HIV-positive patients in a rural Tanzanian setting. The rapid diagnostic test Determine HBsAg is an accurate assay for screening for HBsAg in HIV-1 infected patients at the point of care and may further help to guide cART in Sub-Saharan Africa.

  5. Impact of introduction of rapid diagnostic tests for malaria on antibiotic prescribing

    DEFF Research Database (Denmark)

    Hopkins, Heidi; Bruxvoort, Katia J; Cairns, Matthew E

    2017-01-01

    Objectives To examine the impact of use of rapid diagnostic tests for malaria on prescribing of antimicrobials, specifically antibiotics, for acute febrile illness in Africa and Asia.Design Analysisof nine preselected linked and codesigned observational and randomised studies (eight cluster...... or individually randomised trials and one observational study).Setting Public and private healthcare settings, 2007-13, in Afghanistan, Cameroon, Ghana, Nigeria, Tanzania, and Uganda.Participants 522 480 children and adults with acute febrile illness.Interventions Rapid diagnostic tests for malaria.Main outcome...... in different settings.Results Antibiotics were prescribed to 127 052/238 797 (53%) patients in control groups and 167 714/283 683 (59%) patients in intervention groups. Antibiotics were prescribed to 40% (35 505/89 719) of patients with a positive test result for malaria and to 69% (39 400/57 080) of those...

  6. Antimicrobial susceptibility testing of rapidly growing mycobacteria by microdilution - Experience of a tertiary care centre

    Directory of Open Access Journals (Sweden)

    Set R

    2010-01-01

    Full Text Available Purpose: The objective of the study was to perform antimicrobial susceptibility testing of rapidly growing mycobacteria (RGM isolated from various clinically suspected cases of extrapulmonary tuberculosis, from January 2007 to April 2008, at a tertiary care centre in Mumbai. Materials and Methods: The specimens were processed for microscopy and culture using the standard procedures. Minimum inhibitory concentrations (MIC were determined by broth microdilution, using Sensititre CA MHBT. Susceptibility testing was also carried out on Mueller Hinton agar by the Kirby Bauer disc diffusion method. Results: Of the 1062 specimens received for mycobacterial cultures, 104 (9.79% grew mycobacteria. Of the mycobacterial isolates, six (5.76% were rapid growers. M. abscessus and M. chelonae appeared to be resistant organisms, with M. chelonae showing intermediate resistance to amikacin and minocycline. However, all the six isolates showed sensitivity to vancomycin and gentamicin by the disc diffusion test. Also all three isolates of M. abscessus were sensitive to piperacillin and erythromycin. Further studies are required to test their sensitivity to these four antimicrobials by using the microbroth dilution test, before they can be prescribed to patients. Conclusions: We wish to emphasize that reporting of rapidly growing mycobacteria from clinical settings, along with their sensitivity patterns, is an absolute need of the hour.

  7. Optimization of a rapid diagnostic test for detection of group B streptococcus from antepartum patients.

    Science.gov (United States)

    Faro, Jonathan P; Bishop, Karen; Riddle, Gerald; Katz, Allan; Faro, Sebastian

    2012-07-01

    We analyzed the performance of a new rapid diagnostic test for use in determining group B streptococcus colonization in pregnancy. Vaginal-rectal specimens were compared by the rapid test, a commercial laboratory culture result, and an in-house culture. Of 150 patient samples, 72 were positive by the rapid test, giving a prevalence of 48.0% versus 24.7% by traditional culture. Characterization of these results showed cross-reactivity with Enterococcus. The addition of bacitracin reduced this interference, and when reanalyzed, a colonization rate of 31.3% was found (P = 0.3961, chi-square), as well as a sensitivity of 100% (95% confidence interval [CI] 89.1-100) and a specificity of 93.6% (95% CI 86.9-97.2). The addition of bacitracin greatly improves the reliability of this diagnostic test and demonstrates a novel approach to reduce interference. An accurate determination of the test's sensitivity and specificity, however, awaits enrollment of the remaining subjects. Copyright © 2012 Elsevier Inc. All rights reserved.

  8. Misdiagnosis of HIV infection during a South African community-based survey: implications for rapid HIV testing.

    Science.gov (United States)

    Kufa, Tendesayi; Kharsany, Ayesha Bm; Cawood, Cherie; Khanyile, David; Lewis, Lara; Grobler, Anneke; Chipeta, Zawadi; Bere, Alfred; Glenshaw, Mary; Puren, Adrian

    2017-08-29

    We describe the overall accuracy and performance of a serial rapid HIV testing algorithm used in community-based HIV testing in the context of a population-based household survey conducted in two sub-districts of uMgungundlovu district, KwaZulu-Natal, South Africa, against reference fourth-generation HIV-1/2 antibody and p24 antigen combination immunoassays. We discuss implications of the findings on rapid HIV testing programmes. Cross-sectional design: Following enrolment into the survey, questionnaires were administered to eligible and consenting participants in order to obtain demographic and HIV-related data. Peripheral blood samples were collected for HIV-related testing. Participants were offered community-based HIV testing in the home by trained field workers using a serial algorithm with two rapid diagnostic tests (RDTs) in series. In the laboratory, reference HIV testing was conducted using two fourth-generation immunoassays with all positives in the confirmatory test considered true positives. Accuracy, sensitivity, specificity, positive predictive value, negative predictive value and false-positive and false-negative rates were determined. Of 10,236 individuals enrolled in the survey, 3740 were tested in the home (median age 24 years (interquartile range 19-31 years), 42.1% males and HIV positivity on RDT algorithm 8.0%). From those tested, 3729 (99.7%) had a definitive RDT result as well as a laboratory immunoassay result. The overall accuracy of the RDT when compared to the fourth-generation immunoassays was 98.8% (95% confidence interval (CI) 98.5-99.2). The sensitivity, specificity, positive predictive value and negative predictive value were 91.1% (95% CI 87.5-93.7), 99.9% (95% CI 99.8-100), 99.3% (95% CI 97.4-99.8) and 99.1% (95% CI 98.8-99.4) respectively. The false-positive and false-negative rates were 0.06% (95% CI 0.01-0.24) and 8.9% (95% CI 6.3-12.53). Compared to true positives, false negatives were more likely to be recently infected on

  9. Misdiagnosis of HIV infection during a South African community-based survey: implications for rapid HIV testing

    Science.gov (United States)

    Kufa, Tendesayi; Kharsany, Ayesha BM; Cawood, Cherie; Khanyile, David; Lewis, Lara; Grobler, Anneke; Chipeta, Zawadi; Bere, Alfred; Glenshaw, Mary; Puren, Adrian

    2017-01-01

    Abstract Introduction: We describe the overall accuracy and performance of a serial rapid HIV testing algorithm used in community-based HIV testing in the context of a population-based household survey conducted in two sub-districts of uMgungundlovu district, KwaZulu-Natal, South Africa, against reference fourth-generation HIV-1/2 antibody and p24 antigen combination immunoassays. We discuss implications of the findings on rapid HIV testing programmes. Methods: Cross-sectional design: Following enrolment into the survey, questionnaires were administered to eligible and consenting participants in order to obtain demographic and HIV-related data. Peripheral blood samples were collected for HIV-related testing. Participants were offered community-based HIV testing in the home by trained field workers using a serial algorithm with two rapid diagnostic tests (RDTs) in series. In the laboratory, reference HIV testing was conducted using two fourth-generation immunoassays with all positives in the confirmatory test considered true positives. Accuracy, sensitivity, specificity, positive predictive value, negative predictive value and false-positive and false-negative rates were determined. Results: Of 10,236 individuals enrolled in the survey, 3740 were tested in the home (median age 24 years (interquartile range 19–31 years), 42.1% males and HIV positivity on RDT algorithm 8.0%). From those tested, 3729 (99.7%) had a definitive RDT result as well as a laboratory immunoassay result. The overall accuracy of the RDT when compared to the fourth-generation immunoassays was 98.8% (95% confidence interval (CI) 98.5–99.2). The sensitivity, specificity, positive predictive value and negative predictive value were 91.1% (95% CI 87.5–93.7), 99.9% (95% CI 99.8–100), 99.3% (95% CI 97.4–99.8) and 99.1% (95% CI 98.8–99.4) respectively. The false-positive and false-negative rates were 0.06% (95% CI 0.01–0.24) and 8.9% (95% CI 6.3–12.53). Compared to true positives

  10. The use of the rapid osmotic fragility test as an additional test to diagnose canine immune-mediated haemolytic anaemia

    DEFF Research Database (Denmark)

    Paes, Geert; Paepe, Dominique; Meyer, Evelyne

    2013-01-01

    hyperlipemic dogs (group 3), 10 dogs with lymphoma (group 4), 8 dogs with an infection (group 5) and 13 healthy dogs (group 6) were included. In all dogs, blood smear examination, in-saline auto-agglutination test, Coombs' test, COFT and ROFT were performed. In the COFT, OF5, OF50 and OF90 were defined......Background: Diagnosing canine immune-mediated haemolytic anaemia (IMHA) is often challenging because all currently available tests have their limitations. Dogs with IMHA often have an increased erythrocyte osmotic fragility (OF), a characteristic that is sometimes used in the diagnosis of IMHA....... Since the classic osmotic fragility test (COFT) is time-consuming and requires specialized equipment, an easy and less labour-intensive rapid osmotic fragility test (ROFT) has been used in some countries, but its diagnostic value has not yet been investigated. This study aimed to evaluate erythrocyte...

  11. Detection of antibodies against H5 and H7 strains in birds: evaluation of influenza pseudovirus particle neutralization tests

    Directory of Open Access Journals (Sweden)

    Sofie Wallerström

    2014-01-01

    Full Text Available Introduction: Avian influenza viruses circulate in bird populations, and it is important to maintain and uphold our knowledge of the viral strains that are currently of interest in this context. Here, we describe the use of hemagglutinin-pseudotype retroviruses based on highly pathogenic influenza viruses for the screening of avian sera for influenza A antibodies. Our aim was also to determine whether the pseudovirus neutralization tests that we assessed were sensitive and simple to use compared to the traditional methods, including hemagglutination inhibition assays and microneutralization tests. Material and methods: H5 and H7 pseudovirus neutralization tests were evaluated by using serum from infected rabbits. Subsequently, the assays were further investigated using a panel of serum samples from avian species. The panel contained samples that were seropositive for five different hemagglutinin subtypes as well as influenza A seronegative samples. Results and discussion: The results suggest that the pseudovirus neutralization test is an alternative to hemagglutination inhibition assays, as we observed comparable titers to those of both standard microneutralizations assays as well as hemagglutinin inhibition assays. When evaluated by a panel of avian sera, the method also showed its capability to recognize antibodies directed toward low-pathogenic H5 and H7. Hence, we conclude that it is possible to use pseudoviruses based on highly pathogenic avian influenza viruses to screen avian sera for antibodies directed against influenza A subtypes H5 and H7.

  12. Periodontal disease and Helicobacter pylori infection: a community-based study using serology and rapid urease test.

    Science.gov (United States)

    Nisha, Krishnavilasom J; Nandakumar, Krishnankutty; Shenoy, Kottacherry T; Janam, Presanthila

    2016-02-01

    The aims of the present study were to assess the prevalence of periodontal disease and Helicobacter pylori (H. pylori) infection and their associations within a predefined Indian population. A community-based cross-sectional study of 500 selected individuals using a questionnaire, oral examination, rapid urease testing of dental plaque, and serological examination for immunoglobulin G antibody to H. pylori was carried out. Periodontal disease and H. pylori infection were prevalent in more than 50% of the population. Age, smoking, and diabetic status of the individuals were risk factors for periodontal disease after multivariate analysis, and a lack of proper sewage and waste disposal facilities were found to increase the risk of H. pylori infection. Although there was no association between periodontal disease and H. pylori seropositivity in the community, a highly-significant association was found between periodontal disease and colonization of H. pylori in dental plaque. Because periodontal disease is associated with the increased colonization of H. pylori, new treatment modalities, such as plaque control measures, should be employed for the complete management of H. pylori-associated gastric disease. © 2014 Wiley Publishing Asia Pty Ltd.

  13. Lateral flow test strip based on colloidal selenium immunoassay for rapid detection of melamine in milk, milk powder, and animal feed.

    Science.gov (United States)

    Wang, Zhizeng; Zhi, Dejuan; Zhao, Yang; Zhang, Hailong; Wang, Xin; Ru, Yi; Li, Hongyu

    2014-01-01

    Although high melamine (MEL) intake has been proven to cause serious health problems, MEL is sometimes illegally added to milk products and animal feed, arousing serious food safety concerns. A satisfactory method of detecting MEL in onsite or in-home testing is in urgent need of development. This work aimed to explore a rapid, convenient, and cost-effective method of identifying MEL in milk products or other food by colloidal selenium-based lateral flow immunoassay. Colloidal selenium was synthesized by L-ascorbic acid to reduce seleninic acid at room temperature. After conjugation with a monoclonal antibody anti-MEL, a test strip was successfully prepared. The detection limit of the test strip reached 150 μg/kg, 1,000 μg/kg, and 800 μg/kg in liquid milk, milk powder, and animal feed, respectively. No cross-reactions with homologues cyanuric acid, cyanurodiamide, or ammelide were found. Moreover, the MEL test strip can remain stable after storage for 1 year at room temperature. Our results demonstrate that the colloidal selenium MEL test strip can detect MEL in adulterated milk products or animal feed conveniently, rapidly, and sensitively. In contrast with a colloidal gold MEL test strip, the colloidal selenium MEL test strip was easy to prepare and more cost-efficient.

  14. Screening of the adult population in Iran for coeliac disease: comparison of the tissue-transglutaminase antibody and anti-endomysial antibody tests.

    Science.gov (United States)

    Akbari, Mohammad Reza; Mohammadkhani, Ashraf; Fakheri, Hafez; Javad Zahedi, Mohammad; Shahbazkhani, Bijan; Nouraie, Mehdi; Sotoudeh, Masoud; Shakeri, Ramin; Malekzadeh, Reza

    2006-11-01

    Population-based studies for the prevalence of coeliac disease (CD) in west-Asian countries are scarce. We aimed to determine the prevalence of gluten-sensitive enteropathy (GSE) in the general population of northern and southern Iran, and evaluate the sensitivity and specificity of the anti-endomysial antibody (EMA) immunofluorescent test and the enzyme-linked immunosorbent assay-based test for determination of the IgA anti-tissue transglutaminase antibody (tTG-Ab) using the human recombinant transglutaminase antigen for the detection of CD in screening the asymptomatic adult population. Using a stratified random sampling method we enrolled a total of 2799 individuals (1438 from Sari and 1361 from Kerman). The mean age was 33.7 years (range 18-66), with 1398 men. IgA anti-tissue transglutaminase (tTG) and IgA anti-EMA were determined in the serum of all subjects. Those participants with a positive serology for any of the two tests underwent small intestinal biopsy, and were classified according to revised Marsh criteria histologically. A diagnosis of GSE was based on positive serology and a compatible histopathological finding. The maximum likelihood latent class model was used to estimate the sensitivity and specificity of the two tests. Twenty-nine cases showed positive IgA tTG-Ab (15 men and 14 women, mean age 35.4 years, range 18-59), whereas only five were simultaneously positive for EMA. Except for two subjects with normal small bowel histology (Marsh 0), all other subjects were found to have biopsy findings compatible with GSE: 18 Marsh I, five Marsh II, three Marsh IIIa and one Marsh IIIc lesions. he prevalence of GSE was 0.96% or 1:104. The sensitivity and specificity of the human-recombinant IgA tTG-Ab assay were 100 and 99%, respectively, whereas the results for IgA EMA were 19 and 100%, respectively. The IgA EMA was positive in cases with advanced mucosal lesions of the small bowel. The mean serum value of IgA tTG-Ab was higher in patients with severe

  15. Evaluation of Xenostrip-Tv, a rapid diagnostic test for Trichomonas vaginalis infection.

    Science.gov (United States)

    Pillay, A; Lewis, J; Ballard, R C

    2004-08-01

    An immunochromatographic strip test, Xenostrip-Tv, was compared to wet mount and PCR for the diagnosis of Trichomonas vaginalis infection in women. Of 428 specimens tested, 54 (12.6%) were positive by an "expanded gold standard," defined as either a positive wet mount and PCR test with primers TVK3 and TVK7 and/or a positive PCR test confirmed by a second PCR assay with primers TVA5-1 and TVA6; 26 (6%) were positive by wet mount, and 36 (8.4%) were positive by Xenostrip-Tv test. Since the Xenostrip-Tv test is rapid and easy to perform and proved to be more sensitive than wet mount, it should be considered as an alternative to wet mount for point-of-care diagnosis of trichomoniasis, especially in settings where microscopy is impractical.

  16. Evaluation of capillary zone electrophoresis for charge heterogeneity testing of monoclonal antibodies.

    Science.gov (United States)

    Moritz, Bernd; Schnaible, Volker; Kiessig, Steffen; Heyne, Andrea; Wild, Markus; Finkler, Christof; Christians, Stefan; Mueller, Kerstin; Zhang, Li; Furuya, Kenji; Hassel, Marc; Hamm, Melissa; Rustandi, Richard; He, Yan; Solano, Oscar Salas; Whitmore, Colin; Park, Sung Ae; Hansen, Dietmar; Santos, Marcia; Lies, Mark

    2015-03-01

    with a 30cm capillary which demonstrates that an increased stability indicating potential can be combined with the increased separation velocity and high throughput capability of a shorter capillary. Separation can be performed in as little as approx. 3min allowing high throughput applications. The intercompany study delivered precise results without explicit training of the participating labs in the method prior to the study (standard deviations in the range of 1%). It was demonstrated that CZE is an alternative platform technology for the charge heterogeneity testing of antibodies in the pharmaceutical industry. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Acceptability of rapid oral fluid HIV testing among male injection drug users in Taiwan, 1997 and 2007.

    Science.gov (United States)

    Lyu, Shu-Yu; Morisky, Donald E; Yeh, Ching-Ying; Twu, Shiing-Jer; Peng, Eugene Yu-Chang; Malow, Robert M

    2011-04-01

    Rapid oral fluid HIV testing (rapid oral testing) is in the process of being adapted in Taiwan and elsewhere given its advantages over prior HIV testing methods. To guide this process, we examined the acceptability of rapid oral testing at two time points (i.e., 1997 and 2007) among one of the highest risk populations, male injection drug users (IDUs). For this purpose, an anonymous self-administered survey was completed by HIV-negative IDUs involved in the criminal justice system in 1997 (N (1)=137 parolees) and 2007 (N (2)=106 prisoners). A social marketing model helped guide the design of ou