  1. Considerations for Task Analysis Methods and Rapid E-Learning Development Techniques

    Directory of Open Access Journals (Sweden)

    Dr. Ismail Ipek

    2014-02-01

    Full Text Available The purpose of this paper is to provide basic dimensions for rapid training development in e-learning courses in education and business. Principally, it starts with defining task analysis and how to select tasks for analysis and task analysis methods for instructional design. To do this, first, learning and instructional technologies as visions of the future were discussed. Second, the importance of task analysis methods in rapid e-learning was considered, with learning technologies as asynchronous and synchronous e-learning development. Finally, rapid instructional design concepts and e-learning design strategies were defined and clarified with examples, that is, all steps for effective task analysis and rapid training development techniques based on learning and instructional design approaches were discussed, such as m-learning and other delivery systems. As a result, the concept of task analysis, rapid e-learning development strategies and the essentials of online course design were discussed, alongside learner interface design features for learners and designers.

  2. Uranium solution mining cost estimating technique: means for rapid comparative analysis of deposits

    International Nuclear Information System (INIS)

    Anon.

    1978-01-01

    Twelve graphs provide a technique for determining relative cost ranges for uranium solution mining projects. The use of the technique can provide a consistent framework for rapid comparative analysis of various properties of mining situations. The technique is also useful to determine the sensitivities of cost figures to incremental changes in mining factors or deposit characteristics

  3. Rapid Automated Dissolution and Analysis Techniques for Radionuclides in Recycle Process Streams

    International Nuclear Information System (INIS)

    Sudowe, Ralf; Roman, Audrey; Dailey, Ashlee; Go, Elaine

    2013-01-01

    The analysis of process samples for radionuclide content is an important part of current procedures for material balance and accountancy in the different process streams of a recycling plant. The destructive sample analysis techniques currently available necessitate a significant amount of time. It is therefore desirable to develop new sample analysis procedures that allow for a quick turnaround time and increased sample throughput with a minimum of deviation between samples. In particular, new capabilities for rapid sample dissolution and radiochemical separation are required. Most of the radioanalytical techniques currently employed for sample analysis are based on manual laboratory procedures. Such procedures are time- and labor-intensive, and not well suited for situations in which a rapid sample analysis is required and/or large number of samples need to be analyzed. To address this issue we are currently investigating radiochemical separation methods based on extraction chromatography that have been specifically optimized for the analysis of process stream samples. The influence of potential interferences present in the process samples as well as mass loading, flow rate and resin performance is being studied. In addition, the potential to automate these procedures utilizing a robotic platform is evaluated. Initial studies have been carried out using the commercially available DGA resin. This resin shows an affinity for Am, Pu, U, and Th and is also exhibiting signs of a possible synergistic effects in the presence of iron.

  4. Large-volume constant-concentration sampling technique coupling with surface-enhanced Raman spectroscopy for rapid on-site gas analysis

    Science.gov (United States)

    Zhang, Zhuomin; Zhan, Yisen; Huang, Yichun; Li, Gongke

    2017-08-01

    In this work, a portable large-volume constant-concentration (LVCC) sampling technique coupling with surface-enhanced Raman spectroscopy (SERS) was developed for the rapid on-site gas analysis based on suitable derivatization methods. LVCC sampling technique mainly consisted of a specially designed sampling cell including the rigid sample container and flexible sampling bag, and an absorption-derivatization module with a portable pump and a gas flowmeter. LVCC sampling technique allowed large, alterable and well-controlled sampling volume, which kept the concentration of gas target in headspace phase constant during the entire sampling process and made the sampling result more representative. Moreover, absorption and derivatization of gas target during LVCC sampling process were efficiently merged in one step using bromine-thiourea and OPA-NH4+ strategy for ethylene and SO2 respectively, which made LVCC sampling technique conveniently adapted to consequent SERS analysis. Finally, a new LVCC sampling-SERS method was developed and successfully applied for rapid analysis of trace ethylene and SO2 from fruits. It was satisfied that trace ethylene and SO2 from real fruit samples could be actually and accurately quantified by this method. The minor concentration fluctuations of ethylene and SO2 during the entire LVCC sampling process were proved to be samples were achieved in range of 95.0-101% and 97.0-104% respectively. It is expected that portable LVCC sampling technique would pave the way for rapid on-site analysis of accurate concentrations of trace gas targets from real samples by SERS.

  5. Rapid nuclear forensics analysis via laser based microphotonic techniques coupled with chemometrics

    International Nuclear Information System (INIS)

    Bhatta, B.; Kalambuka, H.A.; Dehayem-Kamadjeu, A.

    2017-01-01

    Nuclear forensics (NF) is an important tool for analysis and attribution of nuclear and radiological materials (NRM) in support of nuclear security. The critical challenge in NF currently is the lack of suitable microanalytical methodologies for direct, rapid and minimally-invasive detection and quantification of NF signatures. Microphotonic techniques can achieve this task particularly when the materials are of limited size and under concealed condition. The purpose of this paper is to demonstrate the combined potential of chemometrics enabled LIBS and laser Raman spectromicroscopy (LRS) for rapid NF analysis and attribution. Using LIBS, uranium lines at 385.464 nm, 385.957 nm and 386.592 nm were identified as NF signatures in uranium ore surrogates. A multivariate calibration strategy using artificial neural network was developed for quantification of trace uranium. Principal component analysis (PCA) of LIBS spectra achieved source attribution of the ores. LRS studies on UCl3, UO3(NO3)2.6H2O, UO2SO4.3H2O and UO3 in pellet state identified the bands associated with different uranium molecules as varying in the range of (840 to 867) ± 15 cm-1. Using this signature, we have demonstrated spectral imaging of uranium under concealed conditions (author)

  6. A histogram-based technique for rapid vector extraction from PIV photographs

    Science.gov (United States)

    Humphreys, William M., Jr.

    1991-01-01

    A new analysis technique, performed totally in the image plane, is proposed which rapidly extracts all available vectors from individual interrogation regions on PIV photographs. The technique avoids the need for using Fourier transforms with the associated computational burden. The data acquisition and analysis procedure is described, and results of a preliminary simulation study to evaluate the accuracy of the technique are presented. Recently obtained PIV photographs are analyzed.

  7. Large-volume constant-concentration sampling technique coupling with surface-enhanced Raman spectroscopy for rapid on-site gas analysis.

    Science.gov (United States)

    Zhang, Zhuomin; Zhan, Yisen; Huang, Yichun; Li, Gongke

    2017-08-05

    In this work, a portable large-volume constant-concentration (LVCC) sampling technique coupling with surface-enhanced Raman spectroscopy (SERS) was developed for the rapid on-site gas analysis based on suitable derivatization methods. LVCC sampling technique mainly consisted of a specially designed sampling cell including the rigid sample container and flexible sampling bag, and an absorption-derivatization module with a portable pump and a gas flowmeter. LVCC sampling technique allowed large, alterable and well-controlled sampling volume, which kept the concentration of gas target in headspace phase constant during the entire sampling process and made the sampling result more representative. Moreover, absorption and derivatization of gas target during LVCC sampling process were efficiently merged in one step using bromine-thiourea and OPA-NH 4 + strategy for ethylene and SO 2 respectively, which made LVCC sampling technique conveniently adapted to consequent SERS analysis. Finally, a new LVCC sampling-SERS method was developed and successfully applied for rapid analysis of trace ethylene and SO 2 from fruits. It was satisfied that trace ethylene and SO 2 from real fruit samples could be actually and accurately quantified by this method. The minor concentration fluctuations of ethylene and SO 2 during the entire LVCC sampling process were proved to be gas targets from real samples by SERS. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Histogram analysis for smartphone-based rapid hematocrit determination

    Science.gov (United States)

    Jalal, Uddin M.; Kim, Sang C.; Shim, Joon S.

    2017-01-01

    A novel and rapid analysis technique using histogram has been proposed for the colorimetric quantification of blood hematocrits. A smartphone-based “Histogram” app for the detection of hematocrits has been developed integrating the smartphone embedded camera with a microfluidic chip via a custom-made optical platform. The developed histogram analysis shows its effectiveness in the automatic detection of sample channel including auto-calibration and can analyze the single-channel as well as multi-channel images. Furthermore, the analyzing method is advantageous to the quantification of blood-hematocrit both in the equal and varying optical conditions. The rapid determination of blood hematocrits carries enormous information regarding physiological disorders, and the use of such reproducible, cost-effective, and standard techniques may effectively help with the diagnosis and prevention of a number of human diseases. PMID:28717569

  9. TV content analysis techniques and applications

    CERN Document Server

    Kompatsiaris, Yiannis

    2012-01-01

    The rapid advancement of digital multimedia technologies has not only revolutionized the production and distribution of audiovisual content, but also created the need to efficiently analyze TV programs to enable applications for content managers and consumers. Leaving no stone unturned, TV Content Analysis: Techniques and Applications provides a detailed exploration of TV program analysis techniques. Leading researchers and academics from around the world supply scientifically sound treatment of recent developments across the related subject areas--including systems, architectures, algorithms,

  10. Manufacturing implant supported auricular prostheses by rapid prototyping techniques.

    Science.gov (United States)

    Karatas, Meltem Ozdemir; Cifter, Ebru Demet; Ozenen, Didem Ozdemir; Balik, Ali; Tuncer, Erman Bulent

    2011-08-01

    Maxillofacial prostheses are usually fabricated on the models obtained following the impression procedures. Disadvantages of conventional impression techniques used in production of facial prosthesis are deformation of soft tissues caused by impression material and disturbance of the patient due to. Additionally production of prosthesis by conventional methods takes longer time. Recently, rapid prototyping techniques have been developed for extraoral prosthesis in order to reduce these disadvantages of conventional methods. Rapid prototyping technique has the potential to simplify the procedure and decrease the laboratory work required. It eliminates the need for measurement impression procedures and preparation of wax model to be performed by prosthodontists themselves In the near future this technology will become a standard for fabricating maxillofacial prostheses.

  11. Contrast bolus technique with rapid CT scanning

    International Nuclear Information System (INIS)

    Arnold, H.; Kuehne, D.; Rohr, W.; Heller, M.

    1981-01-01

    Twenty-three patients complying with the clinical criteria for brain death were studied by contrast-enhanced CT. In all but one, the great intracranial vessels escaped visualization; accordingly, angiography demonstrated cerebral circulatory arrest. In the remaining case, faint enhancement of the circle of Willis corresponded to angiographic demonstration of the proximal segments of cerebral arteris. Neither in normal brain nor in dead brain did slow CT scanning disclose any postcontrast increase in parenchymal attenuation. An improved technique is proposed to demonstrate the transit of the contrast bolus by rapid CT with image splitting. If cerebral blood flow is preserved, the grey and white matter will enhance significantly following administration of contrast medium. Vice versa, the absence of enhancement confirms brain death, even in instances in which the great cerebral vessels are obscured by hemorrhage or other extensive lesions. Two additional cases of brain death were evaluated by rapid CT scanning. As to brain death, the technique obviates the need for angiography or radionuclide angiography, usually applied in prospective organ donors, because its informative content is superior to that of either method. The CT technique described affords a reliable and safe diagnosis of brain death, and can be interpreted easily. (orig.)

  12. [Rapid multi-elemental analysis on four precious Tibetan medicines based on LIBS technique].

    Science.gov (United States)

    Liu, Xiao-na; Shi, Xin-yuan; Jia, Shuai-yun; Zhao, Na; Wu, Zhi-sheng; Qiao, Yan-jiang

    2015-06-01

    The laser-induced breakdown spectroscopy (LIBS) was applied to perform a qualitative elementary analysis on four precious Tibetan medicines, i. e. Renqing Mangjue, Renqing Changjue, 25-herb coral pills and 25-herb pearl pills. The specific spectra of the four Tibetan medicines were established. In the experiment, Nd: YAG and 1 064 nm-baseband pulse laser were adopted to collect the spectra. A laser beam focused on the surface of the samples to generate plasma. Its spectral signal was detected by using spectrograph. Based on the National Institute of Standard and Technology (NIST) database, LIBS spectral lines were indentified. The four Tibetan medicines mainly included Ca, Na, K, Mg and other elements and C-N molecular band. Specifically, Fe was detected in Renqing Changjue and 25-herb pearl pills; heavy mental elements Hg and Cu were shown in Renqing Mangjue and Renqing Changjue; Ag was found in Renqing Changjue. The results demonstrated that LIBS is a reliable and rapid multi-element analysis on the four Tibetan medicines. With Real-time, rapid and nondestructive advantages, LIBS has a wide application prospect in the element analysis on ethnic medicines.

  13. Manufacturing Implant Supported Auricular Prostheses by Rapid Prototyping Techniques

    OpenAIRE

    Karatas, Meltem Ozdemir; Cifter, Ebru Demet; Ozenen, Didem Ozdemir; Balik, Ali; Tuncer, Erman Bulent

    2011-01-01

    Maxillofacial prostheses are usually fabricated on the models obtained following the impression procedures. Disadvantages of conventional impression techniques used in production of facial prosthesis are deformation of soft tissues caused by impression material and disturbance of the patient due to. Additionally production of prosthesis by conventional methods takes longer time. Recently, rapid prototyping techniques have been developed for extraoral prosthesis in order to reduce these disadv...

  14. Rapid analysis of steels using laser-based techniques

    International Nuclear Information System (INIS)

    Cremers, D.A.; Archuleta, F.L.; Dilworth, H.C.

    1985-01-01

    Based on the data obtained by this study, we conclude that laser-based techniques can be used to provide at least semi-quantitative information about the elemental composition of molten steel. Of the two techniques investigated here, the Sample-Only method appears preferable to the LIBS (laser-induced breakdown spectroscopy) method because of its superior analytical performance. In addition, the Sample-Only method would probably be easier to incorporate into a steel plant environment. However, before either technique can be applied to steel monitoring, additional research is needed

  15. Rapid analysis of molybdenum contents in molybdenum master alloys by X-ray fluorescence technique

    International Nuclear Information System (INIS)

    Tongkong, P.

    1985-01-01

    Determination of molybdenum contents in molybdenum master alloy had been performed using energy dispersive x-ray fluorescence (EDX) technique where analysis were made via standard additions and calibration curves. Comparison of EDX technique with other analyzing techniques, i.e., wavelength dispersive x-ray fluorescence, neutron activation analysis and inductive coupled plasma spectrometry, showed consistency in the results. This technique was found to yield reliable results when molybdenum contents in master alloys were in the range of 13 to 50 percent using HPGe detector or proportional counter. When the required error was set at 1%, the minimum analyzing time was found to be 30 and 60 seconds for Fe-Mo master alloys with molybdenum content of 13.54 and 49.09 percent respectively. For Al-Mo master alloys, the minimum times required were 120 and 300 seconds with molybdenum content of 15.22 and 47.26 percent respectively

  16. Rapid prototyping: An innovative technique in dentistry

    Directory of Open Access Journals (Sweden)

    Shakeba Quadri

    2017-01-01

    Full Text Available Emergence of advanced digital technology has opened up new perspectives for design and production in the field of dentistry. Rapid prototyping (RP is a technique to quickly and automatically construct a three-dimensional (3D model of a part or product using 3D printers or stereolithography machines. RP has various dental applications, such as fabrication of implant surgical guides, zirconia prosthesis and molds for metal castings, maxillofacial prosthesis and frameworks for fixed and removable partial dentures, wax patterns for the dental prosthesis and complete denture. Rapid prototyping presents fascinating opportunities, but the process is difficult as it demands a high level of artistic skill, which means that the dental technicians should be able to work with the models obtained after impression to form a mirror image and achieve good esthetics. This review aims to focus on various RP methods and its application in dentistry.

  17. Rapid Analysis of Corni fructus Using Paper Spray-Mass Spectrometry.

    Science.gov (United States)

    Guo, Yuan; Gu, Zhixin; Liu, Xuemei; Liu, Jingjing; Ma, Ming; Chen, Bo; Wang, Liping

    2017-07-01

    Paper spray-mass spectrometry (PS-MS) is a kind of ambient MS technique for the rapid analysis of samples. Corni fructus has been widely used in traditional Chinese compound preparations and healthy food. However, a number of counterfeits of Corni fructus, such as Crataegi fructus, Lycii fructus, and grape skin are illegally sold in crude herb markets. Therefore, the development of a rapid and high-throughput quality evaluation method is important for ensuring the effectiveness and safety of the crude materials of Corni fructus. To develop PS-MS chemical profiles and a semi-quantitative method of Corni fructus for quality assessment and control, and species distinction of Corni fructus. Both positive and negative ion PS-MS chemical profiles were constructed for species distinction. The statistical analysis of the chemical profiles was accomplished by principal component analysis (PCA). Rapid semi-quantitative analysis of loganin and morroniside in the extracts of Corni fructus were accomplished by PS-MS. The profiles of the Corni fructus and Crataegi fructus samples were clearly clustered into two categories. The limit of quantification (LOQ) in the semi-quantitative analysis was 6 μg/mL and 5.6 μg/mL for loganin and morroniside, respectively. PS-MS is a simple, rapid, and high-throughput method for the quality control and species distinction of Corni fructus. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  18. Applications of neutron activation analysis technique

    International Nuclear Information System (INIS)

    Jonah, S. A.

    2000-07-01

    The technique was developed as far back as 1936 by G. Hevesy and H. Levy for the analysis of Dy using an isotopic source. Approximately 40 elements can be analyzed by instrumental neutron activation analysis (INNA) technique with neutrons from a nuclear reactor. By applying radiochemical separation, the number of elements that can be analysed may be increased to almost 70. Compared with other analytical methods used in environmental and industrial research, NAA has some unique features. These are multi-element capability, rapidity, reproducibility of results, complementarity to other methods, freedom from analytical blank and independency of chemical state of elements. There are several types of neutron sources namely: nuclear reactors, accelerator-based and radioisotope-based sources, but nuclear reactors with high fluxes of neutrons from the fission of 235 U give the most intense irradiation, and hence the highest available sensitivities for NAA. In this paper, the applications of NAA of socio-economic importance are discussed. The benefits of using NAA and related nuclear techniques for on-line applications in industrial process control are highlighted. A brief description of the NAA set-ups at CERT is enumerated. Finally, NAA is compared with other leading analytical techniques

  19. DEVELOPMENT OF RAPID TECHNIQUE FOR DETERMINATION OF THE TOTAL MINERALIZATION OF NATURAL WATERS

    Directory of Open Access Journals (Sweden)

    T. A. Kuchmenko

    2015-01-01

    Full Text Available A new approach has been proposed for rapid and easy evaluation of a indicator of quality and properties of natural water - soluble salt content (mineralization. The method of quartz crystal microbalance is employed at load of the mass-sensitive resonator electrode (BAW-type with investigated water. The degree of correlation between the various indicators related to the contents of salts and insoluble compounds and the level of mineralization obtained by the standard method (gravimetry has been studied. A procedure for salt weighing by single sensor at unilateral load with small sample of natural water has been developed. The optimal conditions for measurement is established using the design of experiment by model 23 . The possibilities of quartz crystal microbalance for determination of non-volatile compounds in the water are described. The calibration of piezosensor is produced by standard solution NaCl (c = 1.000 g / dm3 at optimal conditions of experiment. The adequacy and accuracy of proposed technique is assessed by the correlation between the results of quartz crystal microbalance and conductometry. The correlation between indicators of mineralization established by quartz crystal microbalance and gravimetry is found. It has been obtained an equation that can be used to calculate the standard indicator of the mineralization by the results of a quartz crystal microbalance using single sensor. The approaches to enhance the analytical capabilities of the developed technique for water with low and high mineralization are proposed. The metrological characteristics of quartz crystal microbalance of insoluble compounds in natural water are estimated. A new technique of determination of the mass concentration of the dry residue in water with a conductivity of 0.2 mS or above has been developed, which can be used for rapid analysis of the water at nonlaboratory conditions and in the laboratory for rapid obtaining the information about a sample.

  20. Laser induced breakdown spectroscopy (LIBS) as a rapid tool for material analysis

    International Nuclear Information System (INIS)

    Hussain, T; Gondal, M A

    2013-01-01

    Laser induced breakdown spectroscopy (LIBS) is a novel technique for elemental analysis based on laser-generated plasma. In this technique, laser pulses are applied for ablation of the sample, resulting in the vaporization and ionization of sample in hot plasma which is finally analyzed by the spectrometer. The elements are identified by their unique spectral signatures. LIBS system was developed for elemental analysis of solid and liquid samples. The developed system was applied for qualitative as well as quantitative measurement of elemental concentration present in iron slag and open pit ore samples. The plasma was generated by focusing a pulsed Nd:YAG laser at 1064 nm on test samples to study the capabilities of LIBS as a rapid tool for material analysis. The concentrations of various elements of environmental significance such as cadmium, calcium, magnesium, chromium, manganese, titanium, barium, phosphorus, copper, iron, zinc etc., in these samples were determined. Optimal experimental conditions were evaluated for improving the sensitivity of developed LIBS system through parametric dependence study. The laser-induced breakdown spectroscopy (LIBS) results were compared with the results obtained using standard analytical technique such as inductively couple plasma emission spectroscopy (ICP). Limit of detection (LOD) of our LIBS system were also estimated for the above mentioned elements. This study demonstrates that LIBS could be highly appropriate for rapid online analysis of iron slag and open pit waste.

  1. Laser induced breakdown spectroscopy (LIBS) as a rapid tool for material analysis

    Science.gov (United States)

    Hussain, T.; Gondal, M. A.

    2013-06-01

    Laser induced breakdown spectroscopy (LIBS) is a novel technique for elemental analysis based on laser-generated plasma. In this technique, laser pulses are applied for ablation of the sample, resulting in the vaporization and ionization of sample in hot plasma which is finally analyzed by the spectrometer. The elements are identified by their unique spectral signatures. LIBS system was developed for elemental analysis of solid and liquid samples. The developed system was applied for qualitative as well as quantitative measurement of elemental concentration present in iron slag and open pit ore samples. The plasma was generated by focusing a pulsed Nd:YAG laser at 1064 nm on test samples to study the capabilities of LIBS as a rapid tool for material analysis. The concentrations of various elements of environmental significance such as cadmium, calcium, magnesium, chromium, manganese, titanium, barium, phosphorus, copper, iron, zinc etc., in these samples were determined. Optimal experimental conditions were evaluated for improving the sensitivity of developed LIBS system through parametric dependence study. The laser-induced breakdown spectroscopy (LIBS) results were compared with the results obtained using standard analytical technique such as inductively couple plasma emission spectroscopy (ICP). Limit of detection (LOD) of our LIBS system were also estimated for the above mentioned elements. This study demonstrates that LIBS could be highly appropriate for rapid online analysis of iron slag and open pit waste.

  2. Rapid Detection of Biological and Chemical Threat Agents Using Physical Chemistry, Active Detection, and Computational Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Myung; Dong, Li; Fu, Rong; Liotta, Lance; Narayanan, Aarthi; Petricoin, Emanuel; Ross, Mark; Russo, Paul; Zhou, Weidong; Luchini, Alessandra; Manes, Nathan; Chertow, Jessica; Han, Suhua; Kidd, Jessica; Senina, Svetlana; Groves, Stephanie

    2007-01-01

    Basic technologies have been successfully developed within this project: rapid collection of aerosols and a rapid ultra-sensitive immunoassay technique. Water-soluble, humidity-resistant polyacrylamide nano-filters were shown to (1) capture aerosol particles as small as 20 nm, (2) work in humid air and (3) completely liberate their captured particles in an aqueous solution compatible with the immunoassay technique. The immunoassay technology developed within this project combines electrophoretic capture with magnetic bead detection. It allows detection of as few as 150-600 analyte molecules or viruses in only three minutes, something no other known method can duplicate. The technology can be used in a variety of applications where speed of analysis and/or extremely low detection limits are of great importance: in rapid analysis of donor blood for hepatitis, HIV and other blood-borne infections in emergency blood transfusions, in trace analysis of pollutants, or in search of biomarkers in biological fluids. Combined in a single device, the water-soluble filter and ultra-sensitive immunoassay technique may solve the problem of early warning type detection of aerosolized pathogens. These two technologies are protected with five patent applications and are ready for commercialization.

  3. A review of rapid prototyping techniques for tissue engineering purposes

    NARCIS (Netherlands)

    Peltola, Sanna M.; Melchels, Ferry P. W.; Grijpma, Dirk W.; Kellomaki, Minna

    2008-01-01

    Rapid prototyping (RP) is a common name for several techniques, which read in data from computer-aided design (CAD) drawings and manufacture automatically three-dimensional objects layer-by-layer according to the virtual design. The utilization of RP in tissue engineering enables the production of

  4. Simulation of the fissureless technique for thoracoscopic segmentectomy using rapid prototyping.

    Science.gov (United States)

    Akiba, Tadashi; Nakada, Takeo; Inagaki, Takuya

    2015-01-01

    The fissureless lobectomy or anterior fissureless technique is a novel surgical technique, which avoids dissection of the lung parenchyma over the pulmonary artery during lobectomy by open thoracotomy approach or direct vision thoracoscopic surgery. This technique is indicated for fused lobes. We present two cases where thoracoscopic pulmonary segmentectomy was performed using the fissureless technique simulated by three-dimensional (3D) pulmonary models. The 3D model and rapid prototyping provided an accurate anatomical understanding of the operative field in both cases. We believe that the construction of these models is useful for thoracoscopic and other complicated surgeries of the chest.

  5. Simulation of the Fissureless Technique for Thoracoscopic Segmentectomy Using Rapid Prototyping

    Science.gov (United States)

    Nakada, Takeo; Inagaki, Takuya

    2014-01-01

    The fissureless lobectomy or anterior fissureless technique is a novel surgical technique, which avoids dissection of the lung parenchyma over the pulmonary artery during lobectomy by open thoracotomy approach or direct vision thoracoscopic surgery. This technique is indicated for fused lobes. We present two cases where thoracoscopic pulmonary segmentectomy was performed using the fissureless technique simulated by three-dimensional (3D) pulmonary models. The 3D model and rapid prototyping provided an accurate anatomical understanding of the operative field in both cases. We believe that the construction of these models is useful for thoracoscopic and other complicated surgeries of the chest. PMID:24633132

  6. Understanding rapid theoretical change in particle physics: a month-by-month co-citation analysis

    International Nuclear Information System (INIS)

    Sullivan, D.; Koester, D.; White, D.H.; Kern, R.

    1979-01-01

    While co-citation analysis has proved a powerful tool in the study of changes in intellectual foci in science, no one has ever used the technique to study very rapid changes in the theoretical structure of a scientific field. This paper presents month-by-month co-citation analyses of key phases in the weak-electromagnetic unification research program within particle physics, and shows that these analyses capture and illuminate very rapid intellectual changes. These data provide yet another illustration of the utility of co-citation analysis for understanding the history of science. 8 figures

  7. Review and classification of variability analysis techniques with clinical applications

    Science.gov (United States)

    2011-01-01

    Analysis of patterns of variation of time-series, termed variability analysis, represents a rapidly evolving discipline with increasing applications in different fields of science. In medicine and in particular critical care, efforts have focussed on evaluating the clinical utility of variability. However, the growth and complexity of techniques applicable to this field have made interpretation and understanding of variability more challenging. Our objective is to provide an updated review of variability analysis techniques suitable for clinical applications. We review more than 70 variability techniques, providing for each technique a brief description of the underlying theory and assumptions, together with a summary of clinical applications. We propose a revised classification for the domains of variability techniques, which include statistical, geometric, energetic, informational, and invariant. We discuss the process of calculation, often necessitating a mathematical transform of the time-series. Our aims are to summarize a broad literature, promote a shared vocabulary that would improve the exchange of ideas, and the analyses of the results between different studies. We conclude with challenges for the evolving science of variability analysis. PMID:21985357

  8. Review and classification of variability analysis techniques with clinical applications.

    Science.gov (United States)

    Bravi, Andrea; Longtin, André; Seely, Andrew J E

    2011-10-10

    Analysis of patterns of variation of time-series, termed variability analysis, represents a rapidly evolving discipline with increasing applications in different fields of science. In medicine and in particular critical care, efforts have focussed on evaluating the clinical utility of variability. However, the growth and complexity of techniques applicable to this field have made interpretation and understanding of variability more challenging. Our objective is to provide an updated review of variability analysis techniques suitable for clinical applications. We review more than 70 variability techniques, providing for each technique a brief description of the underlying theory and assumptions, together with a summary of clinical applications. We propose a revised classification for the domains of variability techniques, which include statistical, geometric, energetic, informational, and invariant. We discuss the process of calculation, often necessitating a mathematical transform of the time-series. Our aims are to summarize a broad literature, promote a shared vocabulary that would improve the exchange of ideas, and the analyses of the results between different studies. We conclude with challenges for the evolving science of variability analysis.

  9. Use of computer tomography and 3DP Rapid Prototyping technique in cranioplasty planning - analysis of accuracy of bone defect modeling

    International Nuclear Information System (INIS)

    Markowska, O.; Gardzinska, A.; Miechowicz, S.; Chrzan, R.; Urbanik, A.; Miechowicz, S.

    2009-01-01

    Background: The accuracy considerations of alignment of skull bone loss and artificial model of implant are presented. In standard surgical treatment the application of prefabricated alloplastic implants requires complicated procedures during surgery, especially additional geometry processing to provide better adjustment of implant. Rapid Prototyping can be used as an effective tool to generate complex 3D medical models and to improve and simplify surgical treatment planning. The operation time can also be significantly reduced. The aim of the study is adjustment accuracy analysis by measurements of fissure between the bone loss and implant. Material/Methods: The 3D numerical model was obtained from CT imaging with Siemens Sensation 10 CT scanner. The physical models were fabricated with 3DP Rapid Prototyping technology. The measurements were performed in determined points of the bone loss and implant borders. Results: Maximal width of fissure between bone loss and implant was 1.8 mm and minimal 0 mm. Average width was 0.714 mm, standard deviation 0.663 mm. Conclusions: Accuracy of 3DP technique is enough to create medical models in selected field of medicine. Models created using RP methods may be then used to produce implants of biocompatible material, for example by vacuum casting. Using of method suggested may allow shortening of presurgery and surgery time. (authors)

  10. Rapid thyroid dysfunction screening based on serum surface-enhanced Raman scattering and multivariate statistical analysis

    Science.gov (United States)

    Tian, Dayong; Lü, Guodong; Zhai, Zhengang; Du, Guoli; Mo, Jiaqing; Lü, Xiaoyi

    2018-01-01

    In this paper, serum surface-enhanced Raman scattering and multivariate statistical analysis are used to investigate a rapid screening technique for thyroid function diseases. At present, the detection of thyroid function has become increasingly important, and it is urgently necessary to develop a rapid and portable method for the detection of thyroid function. Our experimental results show that, by using the Silmeco-based enhanced Raman signal, the signal strength greatly increases and the characteristic peak appears obviously. It is also observed that the Raman spectra of normal and anomalous thyroid function human serum are significantly different. Principal component analysis (PCA) combined with linear discriminant analysis (LDA) was used to diagnose thyroid dysfunction, and the diagnostic accuracy was 87.4%. The use of serum surface-enhanced Raman scattering technology combined with PCA-LDA shows good diagnostic performance for the rapid detection of thyroid function. By means of Raman technology, it is expected that a portable device for the rapid detection of thyroid function will be developed.

  11. Atmospheric Pressure-Thermal Desorption (AP-TD)/Electrospray Ionization-Mass Spectrometry for the Rapid Analysis of Bacillus Spores

    Science.gov (United States)

    A technique is described where an atmospheric pressure-thermal desorption (AP-TD) device and electrospray ionization (ESI)-mass spectrometry are coupled and used for the rapid analysis of Bacillus spores in complex matrices. The resulting AP-TD/ESI-MS technique combines the generation of volatile co...

  12. Rapid analysis of pharmaceutical drugs using LIBS coupled with multivariate analysis.

    Science.gov (United States)

    Tiwari, P K; Awasthi, S; Kumar, R; Anand, R K; Rai, P K; Rai, A K

    2018-02-01

    Type 2 diabetes drug tablets containing voglibose having dose strengths of 0.2 and 0.3 mg of various brands have been examined, using laser-induced breakdown spectroscopy (LIBS) technique. The statistical methods such as the principal component analysis (PCA) and the partial least square regression analysis (PLSR) have been employed on LIBS spectral data for classifying and developing the calibration models of drug samples. We have developed the ratio-based calibration model applying PLSR in which relative spectral intensity ratios H/C, H/N and O/N are used. Further, the developed model has been employed to predict the relative concentration of element in unknown drug samples. The experiment has been performed in air and argon atmosphere, respectively, and the obtained results have been compared. The present model provides rapid spectroscopic method for drug analysis with high statistical significance for online control and measurement process in a wide variety of pharmaceutical industrial applications.

  13. Technique for rapid detection of phthalates in water and beverages

    KAUST Repository

    Zia, Asif I.

    2013-05-01

    The teratogenic and carcinogenic effects of phthalate esters on living beings are proven in toxicology studies. These ubiquitous food and environmental pollutants pose a great danger to the human race due to their extraordinary use as a plasticizer in the consumer product industry. Contemporary detection techniques used for phthalates require a high level of skills, expensive equipment and longer analysis time than the presented technique. Presented research work introduces a real time non-invasive detection technique using a new type of silicon substrate based planar interdigital (ID) sensor fabricated on basis of thin film micro-electromechanical system (MEMS) semiconductor device fabrication technology. Electrochemical impedance spectroscopy (EIS) was used in conjunction with the fabricated sensor to detect phthalates in deionized water. Various concentrations of di(2-ethylhexyl) phthalate (DEHP) as low as 2 ppb to a higher level of 2 ppm in deionized water were detected distinctively using new planar ID sensor based EIS sensing system. Dip testing method was used to obtain the conductance and dielectric properties of the bulk samples. Parylene C polymer coating was used as a passivation layer on the surface of the fabricated sensor to reduce the influence of Faradaic currents. In addition, inherent dielectric properties of the coating enhanced the sensitivity of the capacitive type sensor. Electrochemical spectrum analysis algorithm was used to model experimentally observed impedance spectrum to deduce constant phase element (CPE) equivalent circuit to analyse the kinetic processes taking place inside the electrochemical cell. Curve fitting technique was used to extract the values of the circuit components and explain experimental results on theoretical grounds. The sensor performance was tested by adding DEHP to an energy drink at concentrations above and below the minimal risk level (MRL) limit set by the ATSDR (Agency for Toxic Substances & Disease Registry

  14. Techniques for rapid determination of effects of synergy between radionuclides and pollutants

    International Nuclear Information System (INIS)

    Saas, A.; Grauby, A.

    1975-01-01

    The authors present a number of chromatographic techniques for rapid determination of synergy between radionuclides and various compounds in water. The first technique consists in studying how the chemical equilibrium of iodine varies in the presence of various organic and mineral compounds. The second makes it possible to define the effects of synergy within a given hydrographic basin. A third technique deals with the effects of synergy in ground water in the presence of various types of irrigation water. Finally, to complete this set of techniques, the authors define the mobility potential of a radionuclide in a given aqueous effluent

  15. A novel technique for presurgical nasoalveolar molding using computer-aided reverse engineering and rapid prototyping.

    Science.gov (United States)

    Yu, Quan; Gong, Xin; Wang, Guo-Min; Yu, Zhe-Yuan; Qian, Yu-Fen; Shen, Gang

    2011-01-01

    To establish a new method of presurgical nasoalveolar molding (NAM) using computer-aided reverse engineering and rapid prototyping technique in infants with unilateral cleft lip and palate (UCLP). Five infants (2 males and 3 females with mean age of 1.2 w) with complete UCLP were recruited. All patients were subjected to NAM before the cleft lip repair. The upper denture casts were recorded using a three-dimensional laser scanner within 2 weeks after birth in UCLP infants. A digital model was constructed and analyzed to simulate the NAM procedure with reverse engineering software. The digital geometrical data were exported to print the solid model with rapid prototyping system. The whole set of appliances was fabricated based on these solid models. Laser scanning and digital model construction simplified the NAM procedure and estimated the treatment objective. The appliances were fabricated based on the rapid prototyping technique, and for each patient, the complete set of appliances could be obtained at one time. By the end of presurgical NAM treatment, the cleft was narrowed, and the malformation of nasoalveolar segments was aligned normally. We have developed a novel technique of presurgical NAM based on a computer-aided design. The accurate digital denture model of UCLP infants could be obtained with laser scanning. The treatment design and appliance fabrication could be simplified with a computer-aided reverse engineering and rapid prototyping technique.

  16. New Strategies for Powder Compaction in Powder-based Rapid Prototyping Techniques

    NARCIS (Netherlands)

    Budding, A.; Vaneker, Thomas H.J.

    2013-01-01

    In powder-based rapid prototyping techniques, powder compaction is used to create thin layers of fine powder that are locally bonded. By stacking these layers of locally bonded material, an object is made. The compaction of thin layers of powder mater ials is of interest for a wide range of

  17. Towards the development of rapid screening techniques for shale gas core properties

    Science.gov (United States)

    Cave, Mark R.; Vane, Christopher; Kemp, Simon; Harrington, Jon; Cuss, Robert

    2013-04-01

    Shale gas has been produced for many years in the U.S.A. and forms around 8% of total their natural gas production. Recent testing for gas on the Fylde Coast in Lancashire UK suggests there are potentially large reserves which could be exploited. The increasing significance of shale gas has lead to the need for deeper understanding of shale behaviour. There are many factors which govern whether a particular shale will become a shale gas resource and these include: i) Organic matter abundance, type and thermal maturity; ii) Porosity-permeability relationships and pore size distribution; iii) Brittleness and its relationship to mineralogy and rock fabric. Measurements of these properties require sophisticated and time consuming laboratory techniques (Josh et al 2012), whereas rapid screening techniques could provide timely results which could improve the efficiency and cost effectiveness of exploration. In this study, techniques which are portable and provide rapid on-site measurements (X-ray Fluorescence (XRF) and Infra-red (IR) spectroscopy) have been calibrated against standard laboratory techniques (Rock-Eval 6 analyser-Vinci Technologies) and Powder whole-rock XRD analysis was carried out using a PANalytical X'Pert Pro series diffractometer equipped with a cobalt-target tube, X'Celerator detector and operated at 45kV and 40mA, to predict properties of potential shale gas material from core material from the Bowland shale Roosecote, south Cumbria. Preliminary work showed that, amongst various mineralogical and organic matter properties of the core, regression models could be used so that the total organic carbon content could be predicted from the IR spectra with a 95 percentile confidence prediction error of 0.6% organic carbon, the free hydrocarbons could be predicted with a 95 percentile confidence prediction error of 0.6 mgHC/g rock, the bound hydrocarbons could be predicted with a 95 percentile confidence prediction error of 2.4 mgHC/g rock, mica content

  18. The rapid determination of manganese, vanadium, and aluminium by instrumental neutron-activation analysis

    International Nuclear Information System (INIS)

    Watterson, J.I.W.; Eddy, B.T.; Pearton, D.C.G.

    1976-01-01

    Aluminium, manganese, and vanadium were determined in chromuim, ferrochromium, and slags. Because of the short-lived isotopes produced, the technique is rapid, and the total analysis time per sample is 15 minutes. The reproducibility is 3 to 4 per cent, and this value can be improved by certain modifications, particularly to the irradiation facilities. A similar method could be applied to on-line or in-plant analysis if an isotopic source of neutrons were used [af

  19. Reliability analysis techniques for the design engineer

    International Nuclear Information System (INIS)

    Corran, E.R.; Witt, H.H.

    1982-01-01

    This paper describes a fault tree analysis package that eliminates most of the housekeeping tasks involved in proceeding from the initial construction of a fault tree to the final stage of presenting a reliability analysis in a safety report. It is suitable for designers with relatively little training in reliability analysis and computer operation. Users can rapidly investigate the reliability implications of various options at the design stage and evolve a system which meets specified reliability objectives. Later independent review is thus unlikely to reveal major shortcomings necessitating modification and project delays. The package operates interactively, allowing the user to concentrate on the creative task of developing the system fault tree, which may be modified and displayed graphically. For preliminary analysis, system data can be derived automatically from a generic data bank. As the analysis proceeds, improved estimates of critical failure rates and test and maintenance schedules can be inserted. The technique is applied to the reliability analysis of the recently upgraded HIFAR Containment Isolation System. (author)

  20. Statistical intensity variation analysis for rapid volumetric imaging of capillary network flux.

    Science.gov (United States)

    Lee, Jonghwan; Jiang, James Y; Wu, Weicheng; Lesage, Frederic; Boas, David A

    2014-04-01

    We present a novel optical coherence tomography (OCT)-based technique for rapid volumetric imaging of red blood cell (RBC) flux in capillary networks. Previously we reported that OCT can capture individual RBC passage within a capillary, where the OCT intensity signal at a voxel fluctuates when an RBC passes the voxel. Based on this finding, we defined a metric of statistical intensity variation (SIV) and validated that the mean SIV is proportional to the RBC flux [RBC/s] through simulations and measurements. From rapidly scanned volume data, we used Hessian matrix analysis to vectorize a segment path of each capillary and estimate its flux from the mean of the SIVs gathered along the path. Repeating this process led to a 3D flux map of the capillary network. The present technique enabled us to trace the RBC flux changes over hundreds of capillaries with a temporal resolution of ~1 s during functional activation.

  1. Rapid scanning system for fuel drawers

    International Nuclear Information System (INIS)

    Caldwell, J.T.; Fehlau, P.E.; France, S.W.

    1981-01-01

    A nondestructive method for uniqely distinguishing among and quantifying the mass of individual fuel plates in situ in fuel drawers utilized in nuclear reactors is described. The method is both rapid and passive, eliminating the personnel hazard of the commonly used irradiation techniques which require that the analysis be performed in proximity to an intense neutron source such as a reactor. In the present technique, only normally decaying nuclei are observed. This allows the analysis to be performed anywhere. This feature, combined with rapid scanning of a given fuel drawer (in approximately 30 s), and the computer data analysis allows the processing of large numbers of fuel drawers efficiently in the event of a loss alert

  2. Learning Over Time: Using Rapid Prototyping Generative Analysis Experts and Reduction of Scope to Operationalize Design

    Science.gov (United States)

    2010-05-04

    during the Vietnam Conflict. 67 David A. Kolb , Experiential Learning : Experience as the Source of Learning and Development. (Upper Saddle River, NJ...Essentials for Military Applications. Newport Paper #10. Newport: Newport War College Press. 1996. Kolb , David A. Experiential Learning : Experience... learning over analysis. A broad review of design theory suggests that four techniques - rapid prototyping, generative analysis, use of experts, and

  3. Finite element analysis (FEA) of dental implant fixture for mechanical stability and rapid osseointegration

    Science.gov (United States)

    Tabassum, Shafia; Murtaza, Ahmar; Ali, Hasan; Uddin, Zia Mohy; Zehra, Syedah Sadaf

    2017-10-01

    For rapid osseointegration of dental implant fixtures, various surface treatments including plasma spraying, hydroxyapatite coating, acid-etching, and surface grooving are used. However undesirable effects such as chemical modifications, loss of mechanical properties, prolonged processing times and post production treatment steps are often associated with these techniques. The osseointegration rate of the dental implants can be promoted by increasing the surface area of the dental implant, thus increasing the bone cells - implant material contact and allow bone tissues to grow rapidly. Additive Manufacturing (AM) techniques can be used to fabricate dental implant fixtures with desirable surface area in a single step manufacturing process. AM allows the use of Computer Aided Designing (CAD) for customised rapid prototyping of components with precise control over geometry. In this study, the dental implant fixture that replaces the tooth root was designed on commercially available software COMSOL. Nickel - titanium alloy was selected as build materials for dental implant. The geometry of the dental fixture was varied by changing the interspacing distance (thread pitch) and number of threads to increase the total surface area. Three different microstructures were introduced on the surface of dental implant. The designed models were used to examine the effect of changing geometries on the total surface area. Finite Element Analysis (FEA) was performed to investigate the effect of changing geometries on the mechanical properties of the dental implant fixtures using stress analysis.

  4. Clan structure analysis and rapidity gap probability

    International Nuclear Information System (INIS)

    Lupia, S.; Giovannini, A.; Ugoccioni, R.

    1995-01-01

    Clan structure analysis in rapidity intervals is generalized from negative binomial multiplicity distribution to the wide class of compound Poisson distributions. The link of generalized clan structure analysis with correlation functions is also established. These theoretical results are then applied to minimum bias events and evidentiate new interesting features, which can be inspiring and useful in order to discuss data on rapidity gap probability at TEVATRON and HERA. (orig.)

  5. Clan structure analysis and rapidity gap probability

    Energy Technology Data Exchange (ETDEWEB)

    Lupia, S. [Turin Univ. (Italy). Ist. di Fisica Teorica]|[Istituto Nazionale di Fisica Nucleare, Turin (Italy); Giovannini, A. [Turin Univ. (Italy). Ist. di Fisica Teorica]|[Istituto Nazionale di Fisica Nucleare, Turin (Italy); Ugoccioni, R. [Turin Univ. (Italy). Ist. di Fisica Teorica]|[Istituto Nazionale di Fisica Nucleare, Turin (Italy)

    1995-03-01

    Clan structure analysis in rapidity intervals is generalized from negative binomial multiplicity distribution to the wide class of compound Poisson distributions. The link of generalized clan structure analysis with correlation functions is also established. These theoretical results are then applied to minimum bias events and evidentiate new interesting features, which can be inspiring and useful in order to discuss data on rapidity gap probability at TEVATRON and HERA. (orig.)

  6. Nuclear techniques for on-line analysis in the mineral and energy industries

    International Nuclear Information System (INIS)

    Sowerby, B.D.; Watt, J.S.

    1994-01-01

    Nuclear techniques are the basis of many on-line analysis systems which are now widely used in the mineral and energy industries. Some of the systems developed by the CSIRO depend entirely on nuclear techniques; others use a combination of nuclear techniques and microwave, capacitance, or ultrasonic techniques. The continuous analysis and rapid response of these CSIRO systems has led to improved control of mining, processing and blending operations, with increased productivity valued at A$50 million per year to Australia, and $90 million per year world wide. This paper reviews developments in nuclear on-line analysis systems by the On-Line Analysis Group in CSIRO at Lucas Heights. Commercialised systems based on this work analyse mineral and coal slurries and determine the ash and moisture contents of coal and coke on conveyors. This paper also reviews two on-line nuclear analysis systems recently developed and licensed to industry, firstly for the determination of the mass flow rates of oil/water/gas mixtures in pipelines, and secondly for determination of the moisture, specific energy, ash and fouling index in low rank coals. 8 refs., 3 tabs., 4 figs

  7. Small area analysis using micro-diffraction techniques

    International Nuclear Information System (INIS)

    Goehner, Raymond P.; Tissot, Ralph G. Jr.; Michael, Joseph R.

    2000-01-01

    used for simultaneous element identification which enhances phase identification of unknowns. The x-ray area detector also allows for rapid microstructure information including crystallite orientation and size by directly observing the diffraction rings. These techniques allow for small area analysis that in the past would have been difficult if not impossible to obtain. The future development in x-ray optics and the use of synchrotron sources will allow for the potential of nondestructive submicron x-ray diffraction analysis

  8. Assessing a new gene expression analysis technique for radiation biodosimetry applications

    Energy Technology Data Exchange (ETDEWEB)

    Manning, Grainne; Kabacik, Sylwia; Finnon, Paul; Paillier, Francois; Bouffler, Simon [Cancer Genetics and Cytogenetics, Biological Effects Department, Centre for Radiation, Chemical and Environmental Hazards, Health Protection Agency, Chilton, Didcot, Oxfordshire OX11 ORQ (United Kingdom); Badie, Christophe, E-mail: christophe.badie@hpa.org.uk [Cancer Genetics and Cytogenetics, Biological Effects Department, Centre for Radiation, Chemical and Environmental Hazards, Health Protection Agency, Chilton, Didcot, Oxfordshire OX11 ORQ (United Kingdom)

    2011-09-15

    The response to any radiation accident or incident involving actual or potential ionising radiation exposure requires accurate and rapid assessment of the doses received by individuals. The techniques available today for biodosimetry purposes are not fully adapted to rapid high-throughput measurements of exposures in large numbers of individuals. A recently emerging technique is based on gene expression analysis, as there are a number of genes which are radiation responsive in a dose-dependent manner. The present work aimed to assess a new technique which allows the detection of the level of expression of up to 800 genes without need of enzymatic reactions. In order to do so, human peripheral blood was exposed ex vivo to a range of x-ray doses from 5 mGy to 4 Gy of x-rays and the transcriptional expression of five radiation-responsive genes PHPT1, PUMA, CCNG1, DDB2 and MDM2 was studied by both the nCounter Digital Analyzer and Multiplex Quantitative Real-Time Polymerase Chain Reaction (MQRT-PCR) as the benchmark technology. Results from both techniques showed good correlation for all genes with R{sup 2} values ranging between 0.8160 and 0.9754. The reproducibility of the nCounter Digital Analyzer was also assessed in independent biological replicates and proved to be good. Although the slopes of the correlation of results obtained by the techniques suggest that MQRT-PCR is more sensitive than the nCounter Digital Analyzer, the nCounter Digital Analyzer provides sensitive and reliable data on modifications in gene expression in human blood exposed to radiation without enzymatic amplification of RNA prior to analysis.

  9. PLEASE: The Python Low-energy Electron Analysis SuitE – Enabling Rapid Analysis of LEEM and LEED Data

    Directory of Open Access Journals (Sweden)

    Maxwell Grady

    2018-02-01

    Full Text Available PLEASE, the Python Low-energy Electron Analysis SuitE, provides an open source and cross-platform graphical user interface (GUI for rapid analysis and visualization of low energy electron microscopy (LEEM data sets. LEEM and the associated technique, selected area micro-spot low energy electron diffraction (μ-LEED, are powerful tools for analysis of the surface structure for many novel materials. Specifically, these tools are uniquely suited for the characterization of two-dimensional materials. PLEASE offers a user-friendly point-and-click method for extracting intensity-voltage curves from LEEM and LEED data sets. Analysis of these curves provides insight into the atomic structure of the target material surface with unparalleled resolution.

  10. A comparative analysis of soft computing techniques for gene prediction.

    Science.gov (United States)

    Goel, Neelam; Singh, Shailendra; Aseri, Trilok Chand

    2013-07-01

    The rapid growth of genomic sequence data for both human and nonhuman species has made analyzing these sequences, especially predicting genes in them, very important and is currently the focus of many research efforts. Beside its scientific interest in the molecular biology and genomics community, gene prediction is of considerable importance in human health and medicine. A variety of gene prediction techniques have been developed for eukaryotes over the past few years. This article reviews and analyzes the application of certain soft computing techniques in gene prediction. First, the problem of gene prediction and its challenges are described. These are followed by different soft computing techniques along with their application to gene prediction. In addition, a comparative analysis of different soft computing techniques for gene prediction is given. Finally some limitations of the current research activities and future research directions are provided. Copyright © 2013 Elsevier Inc. All rights reserved.

  11. Rapid, low-cost, image analysis through video processing

    International Nuclear Information System (INIS)

    Levinson, R.A.; Marrs, R.W.; Grantham, D.G.

    1976-01-01

    Remote Sensing now provides the data necessary to solve many resource problems. However, many of the complex image processing and analysis functions used in analysis of remotely-sensed data are accomplished using sophisticated image analysis equipment. High cost of this equipment places many of these techniques beyond the means of most users. A new, more economical, video system capable of performing complex image analysis has now been developed. This report describes the functions, components, and operation of that system. Processing capability of the new video image analysis system includes many of the tasks previously accomplished with optical projectors and digital computers. Video capabilities include: color separation, color addition/subtraction, contrast stretch, dark level adjustment, density analysis, edge enhancement, scale matching, image mixing (addition and subtraction), image ratioing, and construction of false-color composite images. Rapid input of non-digital image data, instantaneous processing and display, relatively low initial cost, and low operating cost gives the video system a competitive advantage over digital equipment. Complex pre-processing, pattern recognition, and statistical analyses must still be handled through digital computer systems. The video system at the University of Wyoming has undergone extensive testing, comparison to other systems, and has been used successfully in practical applications ranging from analysis of x-rays and thin sections to production of color composite ratios of multispectral imagery. Potential applications are discussed including uranium exploration, petroleum exploration, tectonic studies, geologic mapping, hydrology sedimentology and petrography, anthropology, and studies on vegetation and wildlife habitat

  12. Analysis of Atorvastatin in Commercial Solid Drugs using the TT-PIGE Technique

    International Nuclear Information System (INIS)

    Younes, G; Zahraman, K; Nsouli, B; Bejjani, A; Mahmoud, R; El-Yazbi, F

    2008-01-01

    The quantification of the active ingredient (Al) in drugs is a crucial and important step in the drug quality control process. This is usually performed by using wet chemical techniques like LC-MS, UV spectrophotometry and other appropriate organic analytical methods. In the case of an active ingredient contains specific heteroatoms (F, S, Cl), elemental IBA techniques can be explored for molecular quantification. IBA techniques permit the analysis of the sample under solid form, without any laborious sample preparations. This is an advantage when the number of sample is relatively large. In this work, we demonstrate the ability of the Thick Target PIGE technique for rapid and accurate quantification of low concentration AtorvastatinTM in three commercial anti-hyperlipidemic drugs (Lipitor, Liponorm and Storvas). (author)

  13. Analysis of Atorvastatin in Commercial Solid Drugs using the TT-PIGE Technique

    Energy Technology Data Exchange (ETDEWEB)

    Younes, G [Beirut Arab University, Faculty of Science, Chemistry Department Beirut (Lebanon); Zahraman, K; Nsouli, B; Bejjani, A [Lebanese Atomic Energy Commission, National Council for Scientific Research, Beirut (Lebanon); Mahmoud, R; El-Yazbi, F [Beirut Arab University, Faculty of Pharmacy, Department of Pharmaceutical and Analytical Chemistry, Beirut (Lebanon)

    2008-07-01

    The quantification of the active ingredient (Al) in drugs is a crucial and important step in the drug quality control process. This is usually performed by using wet chemical techniques like LC-MS, UV spectrophotometry and other appropriate organic analytical methods. In the case of an active ingredient contains specific heteroatoms (F, S, Cl), elemental IBA techniques can be explored for molecular quantification. IBA techniques permit the analysis of the sample under solid form, without any laborious sample preparations. This is an advantage when the number of sample is relatively large. In this work, we demonstrate the ability of the Thick Target PIGE technique for rapid and accurate quantification of low concentration AtorvastatinTM in three commercial anti-hyperlipidemic drugs (Lipitor, Liponorm and Storvas). (author)

  14. New Strategies for Powder Compaction in Powder-based Rapid Prototyping Techniques

    OpenAIRE

    Budding, A.; Vaneker, T.H.J.

    2013-01-01

    In powder-based rapid prototyping techniques, powder compaction is used to create thin layers of fine powder that are locally bonded. By stacking these layers of locally bonded material, an object is made. The compaction of thin layers of powder mater ials is of interest for a wide range of applications, but this study solely focuses on the application for powder -based three-dimensional printing (e.g. SLS, 3DP). This research is primarily interested in powder compaction for creating membrane...

  15. Rapid clonal analysis of recurrent tuberculosis by direct MIRU-VNTR typing on stored isolates

    Directory of Open Access Journals (Sweden)

    de Viedma Darío

    2007-07-01

    Full Text Available Abstract Background The application of molecular tools to the analysis of tuberculosis has revealed examples of clonal complexity, such as exogenous reinfection, coinfection, microevolution or compartmentalization. The detection of clonal heterogeneity by standard genotyping approaches is laborious and often requires expertise. This restricts the rapid availability of Mycobacterium tuberculosis (MTB genotypes for clinical or therapeutic decision-making. A new PCR-based technique, MIRU-VNTR, has made it possible to genotype MTB in a time frame close to real-time fingerprinting. Our purpose was to evaluate the capacity of this technique to provide clinicians with a rapid discrimination between reactivation and exogenous reinfection and whether MIRU-VNTR makes it possible to obtain data directly from stored MTB isolates from recurrent episodes. Results We detected differences, between the MIRUtypes of recurrent isolates in 38.5% (5/13 of the cases studied. These included cases of i exogenous reinfection, often with more resistant strains, ii likely examples of microevolution, leading to the appearance of new clonal variants and iii a combination of microevolution, coinfection and competition. Conclusion MIRU-VNTR rapidly obtained clinically useful genotyping data in a challenging situation, directly from stored MTB isolates without subculturing them or purifying their DNA. Our results also mean that MIRU-VNTR could be applied for easy, rapid and affordable massive screening of collections of stored MTB isolates, which could establish the real dimension of clonal heterogeneity in MTB infection.

  16. A microfluidics-based technique for automated and rapid labeling of cells for flow cytometry

    International Nuclear Information System (INIS)

    Patibandla, Phani K; Estrada, Rosendo; Kannan, Manasaa; Sethu, Palaniappan

    2014-01-01

    Flow cytometry is a powerful technique capable of simultaneous multi-parametric analysis of heterogeneous cell populations for research and clinical applications. In recent years, the flow cytometer has been miniaturized and made portable for application in clinical- and resource-limited settings. The sample preparation procedure, i.e. labeling of cells with antibodies conjugated to fluorescent labels, is a time consuming (∼45 min) and labor-intensive procedure. Microfluidics provides enabling technologies to accomplish rapid and automated sample preparation. Using an integrated microfluidic device consisting of a labeling and washing module, we demonstrate a new protocol that can eliminate sample handling and accomplish sample and reagent metering, high-efficiency mixing, labeling and washing in rapid automated fashion. The labeling module consists of a long microfluidic channel with an integrated chaotic mixer. Samples and reagents are precisely metered into this device to accomplish rapid and high-efficiency mixing. The mixed sample and reagents are collected in a holding syringe and held for up to 8 min following which the mixture is introduced into an inertial washing module to obtain ‘analysis-ready’ samples. The washing module consists of a high aspect ratio channel capable of focusing cells to equilibrium positions close to the channel walls. By introducing the cells and labeling reagents in a narrow stream at the center of the channel flanked on both sides by a wash buffer, the elution of cells into the wash buffer away from the free unbound antibodies is accomplished. After initial calibration experiments to determine appropriate ‘holding time’ to allow antibody binding, both modules were used in conjunction to label MOLT-3 cells (T lymphoblast cell line) with three different antibodies simultaneously. Results confirm no significant difference in mean fluorescence intensity values for all three antibodies labels (p < 0.01) between the

  17. Current applications of miniaturized chromatographic and electrophoretic techniques in drug analysis.

    Science.gov (United States)

    Aturki, Zeineb; Rocco, Anna; Rocchi, Silvia; Fanali, Salvatore

    2014-12-01

    In the last decade, miniaturized separation techniques have become greatly popular in pharmaceutical analysis. Miniaturized separation methods are increasingly utilized in all processes of drug discovery as well as quality control of pharmaceutical preparation. The great advantages presented by the analytical miniaturized techniques, including high separation efficiency and resolution, rapid analysis and minimal consumption of reagents and samples, make them an attractive alternative to the conventional chromatographic methods for drug analysis. The purpose of this review is to give a general overview of the applicability of capillary electrophoresis (CE), capillary electrochromatography (CEC) and micro/capillary/nano-liquid chromatography (micro-LC/CLC/nano-LC) for the analysis of pharmaceutical formulations, active pharmaceutical ingredients (API), drug impurity testing, chiral drug separation, determination of drugs and metabolites in biological fluids. The results concerning the use of CEC, micro-LC, CLC, and nano-LC in the period 2009-2013, while for CE, those from 2012 up to the review draft are here summarized and some specific examples are discussed. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Model order reduction techniques with applications in finite element analysis

    CERN Document Server

    Qu, Zu-Qing

    2004-01-01

    Despite the continued rapid advance in computing speed and memory the increase in the complexity of models used by engineers persists in outpacing them. Even where there is access to the latest hardware, simulations are often extremely computationally intensive and time-consuming when full-blown models are under consideration. The need to reduce the computational cost involved when dealing with high-order/many-degree-of-freedom models can be offset by adroit computation. In this light, model-reduction methods have become a major goal of simulation and modeling research. Model reduction can also ameliorate problems in the correlation of widely used finite-element analyses and test analysis models produced by excessive system complexity. Model Order Reduction Techniques explains and compares such methods focusing mainly on recent work in dynamic condensation techniques: - Compares the effectiveness of static, exact, dynamic, SEREP and iterative-dynamic condensation techniques in producing valid reduced-order mo...

  19. [Rapid analysis of suppositories by quantitative 1H NMR spectroscopy].

    Science.gov (United States)

    Abramovich, R A; Kovaleva, S A; Goriainov, S V; Vorob'ev, A N; Kalabin, G A

    2012-01-01

    Rapid analysis of suppositories with ibuprofen and arbidol by quantitative 1H NMR spectroscopy was performed. Optimal conditions for the analysis were developed. The results are useful for design of rapid methods for quality control of suppositories with different components

  20. An XRD technique for quantitative phase analysis of Al-U-Zr alloy

    International Nuclear Information System (INIS)

    Khan, K.B.; Kulkarni, N.K.; Jain, G.C.

    2003-01-01

    In several nuclear research reactors all over the world, Al-U alloy is used as fuel. To stabilise less brittle phase UAl 3 in Al-U alloy, a small amount of Zr (1 to 3 wt% ) is added. A rapid, non destructive and simple x-ray diffraction technique has been developed for quantitative phase analysis Al-U-Zr alloy system containing UAl 4 , UAl 3 and Al. (author)

  1. Research Progress on Pesticide Residue Analysis Techniques in Agro-products

    Directory of Open Access Journals (Sweden)

    HE Ze-ying

    2016-07-01

    Full Text Available There are constant occurrences of acute pesticide poisoning among consumers and pesticide residue violations in agro-products import/export trading. Pesticide residue analysis is the important way to protect the food safety and the interest of import/export enterprises. There has been a rapid development in pesticide residue analysis techniques in recent years. In this review, the research progress in the past five years were discussed in the respects of samples preparation and instrument determination. The application, modification and development of the QuEChERS method in samples preparation and the application of tandem mass spectrometry and high resolution mass spectrometry were reviewed. And the implications for the future of the field were discussed.

  2. Rapid Prototyping and the Human Factors Engineering Process

    Science.gov (United States)

    2016-08-29

    conventional systems development techniques. It is not clear, however, exactly how rapid prototyping could be used in relation to conventional human...factors engineering analyses. Therefore, an investigation of the use of the V APS virtual prototyping system was carried out in five organizations. The...results show that a variety of task analysis approaches can be used to initiate rapid prototyping . Overall, it appears that rapid prototyping

  3. Fast GC-analysis of selected organic compounds at trace levels with the novel RAPID-MS/MS-technology

    International Nuclear Information System (INIS)

    Poell, S.

    2002-03-01

    The main topic of the present thesis was the development of rapid analytical procedures for the environmental analysis of a steel producing company, to speed up the sample throughput for the daily routine work. Additionally, high precision of analysis results was requested. This brought a certain effort concerning the validation of the results which was supported by the analysis of certified reference materials. Special interest was laid on the optimization of the trace analysis of dioxins and furans (PCDD/DF). An expansion of the established methods with powerful techniques like single ion storage and tandem-mass spectrometry resulted in an obvious improvement of the limits of quantitation and the reliability of analysis. Further advances could be achieved with the simplification of the clean-up procedure by the application of a new sampling technique which reduced the demand on sample preparation time as well. Analysis were also carried out with brominated Dioxins and Furans (PBrDD/DF). The next item focused on the analysis of polycyclic aromatic hydrocarbons (PAH) with the implementation of five new representatives with a highly carcinogenic potential. In this case, the coupling of three detectors resulted in a robust and precise HPLC-method with a highly qualitative and quantitative analytical reliability. Furthermore, the aim was to promote the routine analysis of alkylated aromatics (BTEX) and halogenated volatile organic (VOC) compounds. By the use of gas chromatography coupled with mass spectrometric detection a common analytical technique for both classes of substances could be found with an enhancement of sensitivity due to application of the single ion storage technique. The existing method for the determination of polychlorinated biphenyls (PCB) was improved by replacing the electron capture detector with mass spectrometry. Due to an optimization of the single ion storage and tandem mass spectrometry parameters the requested demands on low detection

  4. Rapid analysis of adulterations in Chinese lotus root powder (LRP) by near-infrared (NIR) spectroscopy coupled with chemometric class modeling techniques.

    Science.gov (United States)

    Xu, Lu; Shi, Peng-Tao; Ye, Zi-Hong; Yan, Si-Min; Yu, Xiao-Ping

    2013-12-01

    This paper develops a rapid analysis method for adulteration identification of a popular traditional Chinese food, lotus root powder (LRP), by near-infrared spectroscopy and chemometrics. 85 pure LRP samples were collected from 7 main lotus producing areas of China to include most if not all of the significant variations likely to be encountered in unknown authentic materials. To evaluate the model specificity, 80 adulterated LRP samples prepared by blending pure LRP with different levels of four cheaper and commonly used starches were measured and predicted. For multivariate quality models, two class modeling methods, the traditional soft independent modeling of class analogy (SIMCA) and a recently proposed partial least squares class model (PLSCM) were used. Different data preprocessing techniques, including smoothing, taking derivative and standard normal variate (SNV) transformation were used to improve the classification performance. The results indicate that smoothing, taking second-order derivatives and SNV can improve the class models by enhancing signal-to-noise ratio, reducing baseline and background shifts. The most accurate and stable models were obtained with SNV spectra for both SIMCA (sensitivity 0.909 and specificity 0.938) and PLSCM (sensitivity 0.909 and specificity 0.925). Moreover, both SIMCA and PLSCM could detect LRP samples mixed with 5% (w/w) or more other cheaper starches, including cassava, sweet potato, potato and maize starches. Although it is difficult to perform an exhaustive collection of all pure LRP samples and possible adulterations, NIR spectrometry combined with class modeling techniques provides a reliable and effective method to detect most of the current LRP adulterations in Chinese market. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. Clinical utility of RapidArc™ radiotherapy technology

    International Nuclear Information System (INIS)

    Infusino, Erminia

    2015-01-01

    RapidArc™ is a radiation technique that delivers highly conformal dose distributions through the complete rotation (360°) and speed variation of the linear accelerator gantry. This technique, called volumetric modulated arc therapy (VMAT), compared with conventional radiotherapy techniques, can achieve high-target volume coverage and sparing damage to normal tissues. RapidArc delivers precise dose distribution and conformity similar to or greater than intensity-modulated radiation therapy in a short time, generally a few minutes, to which image-guided radiation therapy is added. RapidArc has become a currently used technology in many centers, which use RapidArc technology to treat a large number of patients. Large and small hospitals use it to treat the most challenging cases, but more and more frequently for the most common cancers. The clinical use of RapidArc and VMAT technology is constantly growing. At present, a limited number of clinical data are published, mostly concerning planning and feasibility studies. Clinical outcome data are increasing for a few tumor sites, even if only a little. The purpose of this work is to discuss the current status of VMAT techniques in clinical use through a review of the published data of planning systems and clinical outcomes in several tumor sites. The study consisted of a systematic review based on analysis of manuscripts retrieved from the PubMed, BioMed Central, and Scopus databases by searching for the keywords “RapidArc”, “Volumetric modulated arc radiotherapy”, and “Intensity-modulated radiotherapy”

  6. Development of Experimental Setup of Metal Rapid Prototyping Machine using Selective Laser Sintering Technique

    Science.gov (United States)

    Patil, S. N.; Mulay, A. V.; Ahuja, B. B.

    2018-04-01

    Unlike in the traditional manufacturing processes, additive manufacturing as rapid prototyping, allows designers to produce parts that were previously considered too complex to make economically. The shift is taking place from plastic prototype to fully functional metallic parts by direct deposition of metallic powders as produced parts can be directly used for desired purpose. This work is directed towards the development of experimental setup of metal rapid prototyping machine using selective laser sintering and studies the various parameters, which plays important role in the metal rapid prototyping using SLS technique. The machine structure in mainly divided into three main categories namely, (1) Z-movement of bed and table, (2) X-Y movement arrangement for LASER movements and (3) feeder mechanism. Z-movement of bed is controlled by using lead screw, bevel gear pair and stepper motor, which will maintain the accuracy of layer thickness. X-Y movements are controlled using timing belt and stepper motors for precise movements of LASER source. Feeder mechanism is then developed to control uniformity of layer thickness metal powder. Simultaneously, the study is carried out for selection of material. Various types of metal powders can be used for metal RP as Single metal powder, mixture of two metals powder, and combination of metal and polymer powder. Conclusion leads to use of mixture of two metals powder to minimize the problems such as, balling effect and porosity. Developed System can be validated by conducting various experiments on manufactured part to check mechanical and metallurgical properties. After studying the results of these experiments, various process parameters as LASER properties (as power, speed etc.), and material properties (as grain size and structure etc.) will be optimized. This work is mainly focused on the design and development of cost effective experimental setup of metal rapid prototyping using SLS technique which will gives the feel of

  7. Rapid analysis and exploration of fluorescence microscopy images.

    Science.gov (United States)

    Pavie, Benjamin; Rajaram, Satwik; Ouyang, Austin; Altschuler, Jason M; Steininger, Robert J; Wu, Lani F; Altschuler, Steven J

    2014-03-19

    Despite rapid advances in high-throughput microscopy, quantitative image-based assays still pose significant challenges. While a variety of specialized image analysis tools are available, most traditional image-analysis-based workflows have steep learning curves (for fine tuning of analysis parameters) and result in long turnaround times between imaging and analysis. In particular, cell segmentation, the process of identifying individual cells in an image, is a major bottleneck in this regard. Here we present an alternate, cell-segmentation-free workflow based on PhenoRipper, an open-source software platform designed for the rapid analysis and exploration of microscopy images. The pipeline presented here is optimized for immunofluorescence microscopy images of cell cultures and requires minimal user intervention. Within half an hour, PhenoRipper can analyze data from a typical 96-well experiment and generate image profiles. Users can then visually explore their data, perform quality control on their experiment, ensure response to perturbations and check reproducibility of replicates. This facilitates a rapid feedback cycle between analysis and experiment, which is crucial during assay optimization. This protocol is useful not just as a first pass analysis for quality control, but also may be used as an end-to-end solution, especially for screening. The workflow described here scales to large data sets such as those generated by high-throughput screens, and has been shown to group experimental conditions by phenotype accurately over a wide range of biological systems. The PhenoBrowser interface provides an intuitive framework to explore the phenotypic space and relate image properties to biological annotations. Taken together, the protocol described here will lower the barriers to adopting quantitative analysis of image based screens.

  8. Determination of Li, B, and F by rapid instrumental neutron activation analysis using beta-particle counting

    International Nuclear Information System (INIS)

    Schmidt, J.O.; Palgaard, L.; Gwozdz, R.; Belhage, L.O.

    1984-01-01

    For the simultaneous determination of Li, B, and F, the application of rapid instrument neutron activation analysis was studied using 1.5s of irradiation and β-particle counting of 8 Li, 12 B, and 20 F. The fast transfer facility, Mach-1, the counting equipment, a 4-channel multiplexer, and a time-base controller are discussed. Further, the technique of simultaneous decay curve analysis of three successive decays is presented and quality control by residual analysis is demonstrated. Finally, analytical results are presented of the NBS-environmental standards Coal-1632a and Coal-1635, and of three BCR-coals intended as references materials

  9. Proposal for Analysis of the Safeguarded Nuclear Materials 235U and 239Pu by Delayed Neutrons Technique

    International Nuclear Information System (INIS)

    El-Mongy, S.A.

    2000-01-01

    This paper introduces, describes and initiates a very sensitive and rapid non-destructive technique to be used for analysis of the safeguarded nuclear materials 235 U and 239 Pu. The technique is based on fission of the nuclear material by neutrons and then measuring the delayed neutrons produced from the neutron rich fission products. By this technique, fissile isotope content ( 235 U) can be determined in the presence of the other fissile (e.g. 239 Pu) or fertile isotopes (e.g. 238 U) in fresh and spent fuel. The time consumed for analysis of bulk materials by this technique is only 4 minutes. The method is also used for analysis of uranium in rock, sediment, soil, meteorites, lunar, biological, urine, archaeological, zircon sand and seawater samples. The method enables uranium in a sample to be measured without respect to its oxidation state, organic and inorganic elements

  10. Rapid Visual Site Analysis for Post-disaster Landscape Planning: Expanding the Range of Choice in a Tsunami-affected Town in Japan

    Directory of Open Access Journals (Sweden)

    James Wescoat

    2012-12-01

    Full Text Available Problem statement In post-disaster situations, it is often necessary to undertake rapid visual site reconnaissance to characterise patterns of damage and identify reconstruction opportunities and constraints. Rapid visual site analysis can occur over a period of hours to days rather than weeks to months. The time constraint is often necessary to assess the viability of initial reconstruction scenarios and help broaden the range of choice among site planning options. Rapid assessment can also minimise the use of scarce local post-disaster resources during the initial reconnaissance phases of planning. Because it involves visual methods rather than equipment-intensive survey techniques, it serves as an initial scoping of alternatives. It may follow emergency shelter response planning methods (for example, Sphere Project, 2011, ch 4 and be followed by more comprehensive site mapping and screening. This action–research project reviews the literature on post-disaster site analysis with an emphasis on the tsunami-affected area of north-eastern Japan. Because research on rapid visual site analysis in post-disaster contexts is limited, we combined field-based site analysis methods, adapted for post-disaster planning, with visual methods for assessing seismic and tsunami hazards.

  11. A comparative study of different techniques in the stress analysis of a nuclear component

    International Nuclear Information System (INIS)

    Dickenson, P.W.; Floyd, C.G.

    1985-01-01

    The inner surface stresses around the corner between the cylindrical wall and end plate of a flat ended pressure vessel have been determined using finite element, boundary element and photoelastic techniques. The results demonstrate severe deficiencies under certain conditions in the performance of the quadrilateral axisymmetric finite element which is commonly used in this type of analysis. The boundary element method is shown to provide an alternative analysis route giving more accurate results. The hybrid formulation finite element is also found to give reasonable results for the analysis of stresses in regions of rapidly varying stress. (orig.)

  12. Rapid structural analysis of nanomaterials in aqueous solutions

    Science.gov (United States)

    Ryuzaki, Sou; Tsutsui, Makusu; He, Yuhui; Yokota, Kazumichi; Arima, Akihide; Morikawa, Takanori; Taniguchi, Masateru; Kawai, Tomoji

    2017-04-01

    Rapid structural analysis of nanoscale matter in a liquid environment represents innovative technologies that reveal the identities and functions of biologically important molecules. However, there is currently no method with high spatio-temporal resolution that can scan individual particles in solutions to gain structural information. Here we report the development of a nanopore platform realizing quantitative structural analysis for suspended nanomaterials in solutions with a high z-axis and xy-plane spatial resolution of 35.8 ± 1.1 and 12 nm, respectively. We used a low thickness-to-diameter aspect ratio pore architecture for achieving cross sectional areas of analyte (i.e. tomograms). Combining this with multiphysics simulation methods to translate ionic current data into tomograms, we demonstrated rapid structural analysis of single polystyrene (Pst) beads and single dumbbell-like Pst beads in aqueous solutions.

  13. Rapid Analysis and Exploration of Fluorescence Microscopy Images

    OpenAIRE

    Pavie, Benjamin; Rajaram, Satwik; Ouyang, Austin; Altschuler, Jason; Steininger, Robert J; Wu, Lani; Altschuler, Steven

    2014-01-01

    Despite rapid advances in high-throughput microscopy, quantitative image-based assays still pose significant challenges. While a variety of specialized image analysis tools are available, most traditional image-analysis-based workflows have steep learning curves (for fine tuning of analysis parameters) and result in long turnaround times between imaging and analysis. In particular, cell segmentation, the process of identifying individual cells in an image, is a major bottleneck in this regard.

  14. Development of techniques for rapid analysis of 90Sr breakthrough and 90Y activity from a 90Sr-90Y generator

    International Nuclear Information System (INIS)

    Chism, S.E.; Goodwin, D.A.; Meares, C.F.

    1986-01-01

    Recently there has been interest in labelling monoclonal antibodies with therapeutic amounts of a pure beta emitting isotope. 90 Y offers many desirable features and may be conveniently and economically obtained from a 90 Sr- 90 Y generator. A potential hazard with this system is breakthrough of the parent 90 Sr which has a half life of 28 years and is an extremely toxic bone seeking isotope. Therefore it is essential that the daughter be completely separated from its parent. We have devised two simple techniques which allow us to monitor rapidly the amount of 90 Sr breakthrough and quantitate the 90 Y activity over a 5 log range. (author)

  15. Rapid analysis of the skin irritant p-phenylenediamine (PPD) in henna products using atmospheric solids analysis probe mass spectrometry.

    Science.gov (United States)

    Chen, Weiyang; Nkosi, Thobile A N; Combrinck, Sandra; Viljoen, Alvaro M; Cartwright-Jones, Catherine

    2016-09-05

    Henna (Lawsonia inermis) is applied to stain keratin, present in hair, skin and fingernails, a red-orange or rust colour. Producers of temporary tattoos mix the aromatic amine compound, para-phenylenediamine (PPD) into natural henna to create 'black henna' that rapidly stains the skin black. However, PPD may cause severe delayed hypersensitivity reactions following skin contact. This study proposes a rapid direct-analysis method to detect and identify PPD using an atmospheric solids analysis probe (ASAP) coupled to a Q-ToF mass spectrometer (MS). Since laborious, multistep methods of analysis to determine PPD are undesirable, due to the instability of the compound in solution, a screening method involving no sample preparation steps was developed. Experiments were carried out to optimise the corona current, sample cone voltage, source temperature, and desolvation gas temperature to determine ideal ASAP-Q-ToF-MS analysing conditions. Eleven of the 109 henna samples, originating from various countries, tested positive for PPD when henna products were screened using ASAP-MS, without any form of sample preparation other than grinding. Ultra-performance liquid chromatography electrospray ionisation-mass spectrometry (UPLC-Q-ToF-MS) was subsequently used to confirm the results from ASAP and to determine the concentrations of PPD in henna products. The allergen was detected in the same eleven samples, with concentrations ranging from 0.05-4.21% (w/w). It can be concluded that the sensitivity of the ASAP-MS technique is sufficient (limit of detection=0.025% w/w) to allow screening of henna samples for the presence of PPD. This relatively new technique can be applied to commercial products without extraction, sample treatment or chromatographic separation. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Surface analysis the principal techniques

    CERN Document Server

    Vickerman, John C

    2009-01-01

    This completely updated and revised second edition of Surface Analysis: The Principal Techniques, deals with the characterisation and understanding of the outer layers of substrates, how they react, look and function which are all of interest to surface scientists. Within this comprehensive text, experts in each analysis area introduce the theory and practice of the principal techniques that have shown themselves to be effective in both basic research and in applied surface analysis. Examples of analysis are provided to facilitate the understanding of this topic and to show readers how they c

  17. Analytical sensitivity of rapid isotopic analysis of water by refractometry for monitoring D2O concentration in nuclear reactor

    International Nuclear Information System (INIS)

    Dhole, K.; Tripathy, M.K.; Ghadigaonkar, R.D.; Datta, A.; Bose, H.; Roy, M.

    2011-01-01

    The feasibility of refractometry for rapid measurement of D 2 O (heavy water) concentration has been studied. Refractometry has been utilised to be an excellent analytical technique to quickly and non-invasively determine D 2 O concentration in water samples without using any chemical reagents. The measurement of refractive index property of water samples with use of temperature control has been utilized for the purpose of their quantitative analysis. The calibration performance provided a reasonable analytical sensitivity of this technique in the 1-100% D 2 O range. (author)

  18. A rapid method for counting nucleated erythrocytes on stained blood smears by digital image analysis

    Science.gov (United States)

    Gering, E.; Atkinson, C.T.

    2004-01-01

    Measures of parasitemia by intraerythrocytic hematozoan parasites are normally expressed as the number of infected erythrocytes per n erythrocytes and are notoriously tedious and time consuming to measure. We describe a protocol for generating rapid counts of nucleated erythrocytes from digital micrographs of thin blood smears that can be used to estimate intensity of hematozoan infections in nonmammalian vertebrate hosts. This method takes advantage of the bold contrast and relatively uniform size and morphology of erythrocyte nuclei on Giemsa-stained blood smears and uses ImageJ, a java-based image analysis program developed at the U.S. National Institutes of Health and available on the internet, to recognize and count these nuclei. This technique makes feasible rapid and accurate counts of total erythrocytes in large numbers of microscope fields, which can be used in the calculation of peripheral parasitemias in low-intensity infections.

  19. Hyperspectral image analysis for rapid and accurate discrimination of bacterial infections: A benchmark study.

    Science.gov (United States)

    Arrigoni, Simone; Turra, Giovanni; Signoroni, Alberto

    2017-09-01

    With the rapid diffusion of Full Laboratory Automation systems, Clinical Microbiology is currently experiencing a new digital revolution. The ability to capture and process large amounts of visual data from microbiological specimen processing enables the definition of completely new objectives. These include the direct identification of pathogens growing on culturing plates, with expected improvements in rapid definition of the right treatment for patients affected by bacterial infections. In this framework, the synergies between light spectroscopy and image analysis, offered by hyperspectral imaging, are of prominent interest. This leads us to assess the feasibility of a reliable and rapid discrimination of pathogens through the classification of their spectral signatures extracted from hyperspectral image acquisitions of bacteria colonies growing on blood agar plates. We designed and implemented the whole data acquisition and processing pipeline and performed a comprehensive comparison among 40 combinations of different data preprocessing and classification techniques. High discrimination performance has been achieved also thanks to improved colony segmentation and spectral signature extraction. Experimental results reveal the high accuracy and suitability of the proposed approach, driving the selection of most suitable and scalable classification pipelines and stimulating clinical validations. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. [Applications of spectral analysis technique to monitoring grasshoppers].

    Science.gov (United States)

    Lu, Hui; Han, Jian-guo; Zhang, Lu-da

    2008-12-01

    Grasshopper monitoring is of great significance in protecting environment and reducing economic loss. However, how to predict grasshoppers accurately and effectively is a difficult problem for a long time. In the present paper, the importance of forecasting grasshoppers and its habitat is expounded, and the development in monitoring grasshopper populations and the common arithmetic of spectral analysis technique are illustrated. Meanwhile, the traditional methods are compared with the spectral technology. Remote sensing has been applied in monitoring the living, growing and breeding habitats of grasshopper population, and can be used to develop a forecast model combined with GIS. The NDVI values can be analyzed throughout the remote sensing data and be used in grasshopper forecasting. Hyper-spectra remote sensing technique which can be used to monitor grasshoppers more exactly has advantages in measuring the damage degree and classifying damage areas of grasshoppers, so it can be adopted to monitor the spatial distribution dynamic of rangeland grasshopper population. Differentialsmoothing can be used to reflect the relations between the characteristic parameters of hyper-spectra and leaf area index (LAI), and indicate the intensity of grasshopper damage. The technology of near infrared reflectance spectroscopy has been employed in judging grasshopper species, examining species occurrences and monitoring hatching places by measuring humidity and nutrient of soil, and can be used to investigate and observe grasshoppers in sample research. According to this paper, it is concluded that the spectral analysis technique could be used as a quick and exact tool in monitoring and forecasting the infestation of grasshoppers, and will become an important means in such kind of research for their advantages in determining spatial orientation, information extracting and processing. With the rapid development of spectral analysis methodology, the goal of sustainable monitoring

  1. Soil analysis. Modern instrumental technique

    International Nuclear Information System (INIS)

    Smith, K.A.

    1993-01-01

    This book covers traditional methods of analysis and specialist monographs on individual instrumental techniques, which are usually not written with soil or plant analysis specifically in mind. The principles of the techniques are combined with discussions of sample preparation and matrix problems, and critical reviews of applications in soil science and related disciplines. Individual chapters are processed separately for inclusion in the appropriate data bases

  2. Application of Rapid Prototyping Technique and Intraoperative Navigation System for the Repair and Reconstruction of Orbital Wall Fractures

    Science.gov (United States)

    Cha, Jong Hyun; Lee, Yong Hae; Ruy, Wan Chul; Roe, Young; Moon, Myung Ho

    2016-01-01

    Background Restoring the orbital cavity in large blow out fractures is a challenge for surgeons due to the anatomical complexity. This study evaluated the clinical outcomes and orbital volume after orbital wall fracture repair using a rapid prototyping (RP) technique and intraoperative navigation system. Methods This prospective study was conducted on the medical records and radiology records of 12 patients who had undergone a unilateral blow out fracture reconstruction using a RP technique and an intraoperative navigation system from November 2014 to March 2015. The surgical results were assessed by an ophthalmic examination and a comparison of the preoperative and postoperative orbital volume ratio (OVR) values. Results All patients had a successful treatment outcome without complications. Volumetric analysis revealed a significant decrease in the mean OVR from 1.0952±0.0662 (ranging from 0.9917 to 1.2509) preoperatively to 0.9942±0.0427 (ranging from 0.9394 to 1.0680) postoperatively. Conclusion The application of a RP technique for the repair of orbital wall fractures is a useful tool that may help improve the clinical outcomes by understanding the individual anatomy, determining the operability, and restoring the orbital cavity volume through optimal implant positioning along with an intraoperative navigation system. PMID:28913272

  3. The zygomatic implant perforated (ZIP) flap: a new technique for combined surgical reconstruction and rapid fixed dental rehabilitation following low-level maxillectomy.

    Science.gov (United States)

    Butterworth, C J; Rogers, S N

    2017-12-01

    This aim of this report is to describe the development and evolution of a new surgical technique for the immediate surgical reconstruction and rapid post-operative prosthodontic rehabilitation with a fixed dental prosthesis following low-level maxillectomy for malignant disease.The technique involves the use of a zygomatic oncology implant perforated micro-vascular soft tissue flap (ZIP flap) for the primary management of maxillary malignancy with surgical closure of the resultant maxillary defect and the installation of osseointegrated support for a zygomatic implant-supported maxillary fixed dental prosthesis.The use of this technique facilitates extremely rapid oral and dental rehabilitation within a few weeks of resective surgery, providing rapid return to function and restoring appearance following low-level maxillary resection, even in cases where radiotherapy is required as an adjuvant treatment post-operatively. The ZIP flap technique has been adopted as a standard procedure in the unit for the management of low-level maxillary malignancy, and this report provides a detailed step-by-step approach to treatment and discusses modifications developed over the treatment of an initial cohort of patients.

  4. Numerical analysis of rapid drawdown: Applications in real cases

    Directory of Open Access Journals (Sweden)

    Eduardo E. Alonso

    2016-07-01

    Full Text Available In this study, rapid drawdown scenarios were analyzed by means of numerical examples as well as modeling of real cases with in situ measurements. The aim of the study was to evaluate different approaches available for calculating pore water pressure distributions during and after a drawdown. To do that, a single slope subjected to a drawdown was first analyzed under different calculation alternatives, and numerical results were discussed. Simple methods, such as undrained analysis and pure flow analysis, implicitly assuming a rigid soil skeleton, lead to significant errors in pore water pressure distributions when compared with coupled flow-deformation analysis. A similar analysis was performed for the upstream slope of the Glen Shira Dam, Scotland, and numerical results were compared with field measurements during a controlled drawdown. Field records indicate that classical undrained calculations are conservative but unrealistic. Then, a recent case of a major landslide triggered by a rapid drawdown in a reservoir was interpreted. A key aspect of the case was the correct characterization of permeability of a representative soil profile. This was achieved by combining laboratory test results and a back analysis of pore water pressure time records during a period of reservoir water level fluctuations. The results highlight the difficulty of predicting whether the pore water pressure is overestimated or underestimated when using simplified approaches, and it is concluded that predicting the pore water pressure distribution in a slope after a rapid drawdown requires a coupled flow-deformation analysis in saturated and unsaturated porous media.

  5. Potential of MALDI-TOF mass spectrometry as a rapid detection technique in plant pathology: identification of plant-associated microorganisms.

    Science.gov (United States)

    Ahmad, Faheem; Babalola, Olubukola O; Tak, Hamid I

    2012-09-01

    Plant diseases caused by plant pathogens substantially reduce crop production every year, resulting in massive economic losses throughout the world. Accurate detection and identification of plant pathogens is fundamental to plant pathogen diagnostics and, thus, plant disease management. Diagnostics and disease-management strategies require techniques to enable simultaneous detection and quantification of a wide range of pathogenic and non-pathogenic microorganisms. Over the past decade, rapid development of matrix-assisted laser-desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) techniques for characterization of microorganisms has enabled substantially improved detection and identification of microorganisms. In the biological sciences, MALDI-TOF MS is used to analyze specific peptides or proteins directly desorbed from intact bacteria, fungal spores, nematodes, and other microorganisms. The ability to record biomarker ions, in a broad m/z range, which are unique to and representative of individual microorganisms, forms the basis of taxonomic identification of microorganisms by MALDI-TOF MS. Recent advances in mass spectrometry have initiated new research, i.e. analysis of more complex microbial communities. Such studies are just beginning but have great potential for elucidation not only of the interactions between microorganisms and their host plants but also those among different microbial taxa living in association with plants. There has been a recent effort by the mass spectrometry community to make data from large scale mass spectrometry experiments publicly available in the form of a centralized repository. Such a resource could enable the use of MALDI-TOF MS as a universal technique for detection of plant pathogens and non-pathogens. The effects of experimental conditions are sufficiently understood, reproducible spectra can be obtained from computational database search, and microorganisms can be rapidly characterized by genus, species

  6. Recent advances in the instrumental techniques for the analysis of modern materials (II)

    International Nuclear Information System (INIS)

    Ahmed, M.

    1990-01-01

    Inductively Coupled Plasma Mass Spectrometry ICP-MS a logical development of equally established sister technique of ICP-AEA discussed in part-1 of this series of article on modern analytical techniques. The rapid adaptation of argon plasma as ion source for time of flight quadrupole mass analyser has led to the development of truly integrated instrumental technique for analysis of solutions and slurries. The powerful combination with laser ablation device has made the direct analysis of geological, geochemical and other complex conducting and non conducting samples possible in days rather months at sub ppm levels. Parallel development in computer hardware and software has made the instrumental optimization easy enabling the generation of meaningful analytical data a matter of routine. The limitations imposed by spectroscopic and non restricted the variety of matrices and materials covered by ICP-MS of LA-ICP-MS. The technique has provided it formidable analytical power in wide areas of industrial environmental, social, biological and break through advanced materials used in space mass communication, transportation and general areas of advanced analytical chemistry. It is expected that in combination with other instrumental methods as HPLC, ETC, ion chromatography. ICP-MS shall continue to dominate well into the 21st century. (author)

  7. Direct rapid analysis of trace bioavailable soil macronutrients by chemometrics-assisted energy dispersive X-ray fluorescence and scattering spectrometry

    International Nuclear Information System (INIS)

    Kaniu, M.I.; Angeyo, K.H.; Mwala, A.K.; Mangala, M.J.

    2012-01-01

    Highlights: ► Chemometrics-assisted EDXRFS spectroscopy realizes direct, rapid and accurate analysis of trace bioavailable macronutrients in soils. ► The method is minimally invasive, involves little sample preparation, short analysis times and is relatively insensitive to matrix effects. ► This opens up the ability to rapidly characterize large number of samples/matrices with this method. - Abstract: Precision agriculture depends on the knowledge and management of soil quality (SQ), which calls for affordable, simple and rapid but accurate analysis of bioavailable soil nutrients. Conventional SQ analysis methods are tedious and expensive. We demonstrate the utility of a new chemometrics-assisted energy dispersive X-ray fluorescence and scattering (EDXRFS) spectroscopy method we have developed for direct rapid analysis of trace ‘bioavailable’ macronutrients (i.e. C, N, Na, Mg, P) in soils. The method exploits, in addition to X-ray fluorescence, the scatter peaks detected from soil pellets to develop a model for SQ analysis. Spectra were acquired from soil samples held in a Teflon holder analyzed using 109 Cd isotope source EDXRF spectrometer for 200 s. Chemometric techniques namely principal component analysis (PCA), partial least squares (PLS) and artificial neural networks (ANNs) were utilized for pattern recognition based on fluorescence and Compton scatter peaks regions, and to develop multivariate quantitative calibration models based on Compton scatter peak respectively. SQ analyses were realized with high CMD (R 2 > 0.9) and low SEP (0.01% for N and Na, 0.05% for C, 0.08% for Mg and 1.98 μg g −1 for P). Comparison of predicted macronutrients with reference standards using a one-way ANOVA test showed no statistical difference at 95% confidence level. To the best of the authors’ knowledge, this is the first time that an XRF method has demonstrated utility in trace analysis of macronutrients in soil or related matrices.

  8. Development of flexural vibration inspection techniques to rapidly assess the structural health of rural bridge systems

    Science.gov (United States)

    Brian K. Brashaw; Robert Vatalaro; Xiping Wang; Kevin Sarvela; James P. Wacker

    2008-01-01

    Approximately 4,000 vehicle bridges in the State of Minnesota contain structural timber members. Recent research at the University of Minnesota Duluth Natural Resources Research Institute (UMD NRRI) has been conducted on vibration testing of timber bridges as a means of developing rapid in-place testing techniques for assessing the structural health of bridges. The...

  9. Application of functional analysis techniques to supervisory systems

    International Nuclear Information System (INIS)

    Lambert, Manuel; Riera, Bernard; Martel, Gregory

    1999-01-01

    The aim of this paper is to apply firstly two interesting functional analysis techniques for the design of supervisory systems for complex processes, and secondly to discuss the strength and the weaknesses of each of them. Two functional analysis techniques have been applied, SADT (Structured Analysis and Design Technique) and FAST (Functional Analysis System Technique) on a process, an example of a Water Supply Process Control (WSPC) system. These techniques allow a functional description of industrial processes. The paper briefly discusses the functions of a supervisory system and some advantages of the application of functional analysis for the design of a 'human' centered supervisory system. Then the basic principles of the two techniques applied on the WSPC system are presented. Finally, the different results obtained from the two techniques are discussed

  10. A rapid inoculation technique for assessing pathogenicity of Fusarium oxysporum f. sp. niveum and F. o. melonis on Cucurbits

    Science.gov (United States)

    Freeman, S.; Rodriguez, R.J.

    1993-01-01

    A continuous-dip inoculation technique for rapid assessment of pathogenicity of Fusarium oxysporum f. sp. niveum and F. o. melonis was developed. The method, adapted from a similar procedure for determining pathogenicity of Colletotrichum magna (causal agent of anthracnose of cucurbits), involves constant exposure of seedlings and cuttings (seedlings with root systems excised) of watermelon and muskmelon to conidial suspensions contained in small scintillation vials. Disease development in intact seedlings corresponded well to disease responses observed with the standard root-dip inoculation/pot assay. The continuous-dip inoculation technique resulted in rapid disease development, with 50% of watermelon cuttings dying after 4–6 days of exposure to F. o. niveum. A mortality of 30% also was observed in watermelon cuttings exposed to conidia of F. o. melonis, as opposed to only a 0–2.5% mortality in seedlings with intact roots. Disease response was similar with muskmelon seedlings and cuttings continuously dip-inoculated with F. o. melonis isolates. However, no disease symptoms were observed in muskmelon seedlings or cuttings inoculated with F. o. niveum. Four nonpathogenic isolates of F. oxysporum did not cause disease symptoms in either watermelon or muskmelon cuttings and seedlings when assayed by this technique. The proposed method enables a rapid screening of pathogenicity and requires less time, labor, and greenhouse space than the standard root-dip inoculation/pot assay. The reliability of the continuous-dip inoculation technique is limited, however, to exposure of intact seedlings at a concentration of 1 × 106conidia per milliliter; the method is not accurate at this range for excised seedlings.

  11. Rapid Genetic Analysis in Congenital Hyperinsulinism

    DEFF Research Database (Denmark)

    Christesen, Henrik Thybo; Brusgaard, Klaus; Alm, Jan

    2007-01-01

    BACKGROUND: In severe, medically unresponsive congenital hyperinsulinism (CHI), the histological differentiation of focal versus diffuse disease is vital, since the surgical management is completely different. Genetic analysis may help in the differential diagnosis, as focal CHI is associated...... with a paternal germline ABCC8 or KCNJ11 mutation and a focal loss of maternal chromosome 11p15, whereas a maternal mutation, or homozygous/compound heterozygous ABCC8 and KCNJ11 mutations predict diffuse-type disease. However, genotyping usually takes too long to be helpful in the absence of a founder mutation....... METHODS: In 4 patients, a rapid genetic analysis of the ABBC8 and KCNJ11 genes was performed within 2 weeks on request prior to the decision of pancreatic surgery. RESULTS: Two patients had no mutations, rendering the genetic analysis non-informative. Peroperative multiple biopsies showed diffuse disease...

  12. A technique for a rapid imaging of regional CBF and partition coefficient using dynamic SPECT and N-isopropyl-p-[123I]iodoamphetamine (123I-IMP)

    International Nuclear Information System (INIS)

    Itoh, Hiroshi; Iida, Hidehiro; Murakami, Matsutaro

    1993-01-01

    IMP (iodoamphetamine) is a flow tracer due to a large first pass extraction fraction and high affinity in the brain, but significant clearance from the brain causes change of distribution when the beginning time of scan is delayed. The purpose of the present study was to develop a new method to rapidly calculate a quantitative cerebral blood flow (CBF) image by taking clearance effects into account. A dynamic SPECT scan was performed on 5 subjects (4 patients with cerebral infarction and one normal volunteer) following slow intravenous infusion of 123 I-IMP. The arterial input function was obtained by frequent blood sampling and by measuring an octanol extraction ratio for each sample. Firstly, non-linear least square fitting (NLS) was performed to investigate the tracer kinetics of 123 I-IMP. The 3 compartment model analysis yielded negligibly small k 3 (retaining rate constant) (0.0056±0.0128 (ml/ml/min)), and consistent k 1 (transport rate constant) with those determined by 2 compartment model (2CM) analysis (r=0.96, p 1 was consistent with CBF measured by 15 O water PET technique. These observations suggested the validity of using 2CM for describing the IMP tracer kinetics. Secondly, a weighted integration (WI) technique has been implemented to calculate rapidly images of CBF and partition coefficient (V d ). The WI technique yielded values of CBF (k 1 ) and V d (k 1 /k 2 ). They were confirmed to be consistent with those determined by NLS technique (CBF; r=0.99, p d ; r=0.99, p 1 agreed well with PET CBF (r=0.91, p d in infarcted patients. This supports an importance for calculating V d image. V d image will provide additional clinical information because 123 I-IMP binding mechanism may be related to cell viability. (author)

  13. Survey of immunoassay techniques for biological analysis

    International Nuclear Information System (INIS)

    Burtis, C.A.

    1986-10-01

    Immunoassay is a very specific, sensitive, and widely applicable analytical technique. Recent advances in genetic engineering have led to the development of monoclonal antibodies which further improves the specificity of immunoassays. Originally, radioisotopes were used to label the antigens and antibodies used in immunoassays. However, in the last decade, numerous types of immunoassays have been developed which utilize enzymes and fluorescent dyes as labels. Given the technical, safety, health, and disposal problems associated with using radioisotopes, immunoassays that utilize the enzyme and fluorescent labels are rapidly replacing those using radioisotope labels. These newer techniques are as sensitive, are easily automated, have stable reagents, and do not have a disposal problem. 6 refs., 1 fig., 2 tabs

  14. Teaching Tip: Using Rapid Game Prototyping for Exploring Requirements Discovery and Modeling

    Science.gov (United States)

    Dalal, Nikunj

    2012-01-01

    We describe the use of rapid game prototyping as a pedagogic technique to experientially explore and learn requirements discovery, modeling, and specification in systems analysis and design courses. Students have a natural interest in gaming that transcends age, gender, and background. Rapid digital game creation is used to build computer games…

  15. A new facility for rapid neutron activation analysis

    International Nuclear Information System (INIS)

    Zeisler, R.; Makarewicz, M.; Grass, F.; Casta, J.

    1996-01-01

    Many research groups have undertaken efforts on the utilization of short-lived nuclides in a broad spectrum of neutron activation analysis (NAA) applications. The advantages of these approaches are obvious because the information on the sample can be extracted more rapidly. In addition to its other advantages, NAA can become extremely competitive in price and analysis time. Nevertheless, NAA with short-lived nuclides has not gained broad popularity, perhaps because of some difficulties in accuracy and the availability of suitable irradiation facilities. This report discusses the ASTRA reactor for neutron activation analysis capabilities

  16. A new rapid immunohistochemical staining technique using the EnVision antibody complex.

    Science.gov (United States)

    Kämmerer, U; Kapp, M; Gassel, A M; Richter, T; Tank, C; Dietl, J; Ruck, P

    2001-05-01

    Rapid immunohistochemical investigation, in addition to staining with hematoxylin and eosin, would be useful during intraoperative frozen section diagnosis in some cases. This study was undertaken to investigate whether the recently described EnVision system, a highly sensitive two-step immunohistochemical technique, could be modified for rapid immunostaining of frozen sections. Forty-five primary antibodies were tested on frozen sections from various different tissues. After fixation in acetone for 1 min and air-drying, the sections were incubated for 3 min each with the primary antibody, the EnVision complex (a large number of secondary antibodies and horseradish peroxidase coupled to a dextran backbone), and the chromogen (3,3'diaminobenzidine or 3-amino-9-ethylcarbazole). All reactions were carried out at 37C. Specific staining was seen with 38 antibodies (including HMB-45 and antibodies against keratin, vimentin, leukocyte common antigen, smooth muscle actin, synaptophysin, CD34, CD3, CD20, and prostate-specific antigen). A modification of the EnVision method allows the detection of a broad spectrum of antigens in frozen sections in less than 13 min. This method could be a useful new tool in frozen section diagnosis and research. (J Histochem Cytochem 49:623-630, 2001)

  17. Microlensing observations rapid search for exoplanets: MORSE code for GPUs

    Science.gov (United States)

    McDougall, Alistair; Albrow, Michael D.

    2016-02-01

    The rapid analysis of ongoing gravitational microlensing events has been integral to the successful detection and characterization of cool planets orbiting low-mass stars in the Galaxy. In this paper, we present an implementation of search and fit techniques on graphical processing unit (GPU) hardware. The method allows for the rapid identification of candidate planetary microlensing events and their subsequent follow-up for detailed characterization.

  18. Macro elemental analysis of food samples by nuclear analytical technique

    Science.gov (United States)

    Syahfitri, W. Y. N.; Kurniawati, S.; Adventini, N.; Damastuti, E.; Lestiani, D. D.

    2017-06-01

    Energy-dispersive X-ray fluorescence (EDXRF) spectrometry is a non-destructive, rapid, multi elemental, accurate, and environment friendly analysis compared with other detection methods. Thus, EDXRF spectrometry is applicable for food inspection. The macro elements calcium and potassium constitute important nutrients required by the human body for optimal physiological functions. Therefore, the determination of Ca and K content in various foods needs to be done. The aim of this work is to demonstrate the applicability of EDXRF for food analysis. The analytical performance of non-destructive EDXRF was compared with other analytical techniques; neutron activation analysis and atomic absorption spectrometry. Comparison of methods performed as cross checking results of the analysis and to overcome the limitations of the three methods. Analysis results showed that Ca found in food using EDXRF and AAS were not significantly different with p-value 0.9687, whereas p-value of K between EDXRF and NAA is 0.6575. The correlation between those results was also examined. The Pearson correlations for Ca and K were 0.9871 and 0.9558, respectively. Method validation using SRM NIST 1548a Typical Diet was also applied. The results showed good agreement between methods; therefore EDXRF method can be used as an alternative method for the determination of Ca and K in food samples.

  19. Time-Resolved Fluorescent Immunochromatography of Aflatoxin B1 in Soybean Sauce: A Rapid and Sensitive Quantitative Analysis.

    Science.gov (United States)

    Wang, Du; Zhang, Zhaowei; Li, Peiwu; Zhang, Qi; Zhang, Wen

    2016-07-14

    Rapid and quantitative sensing of aflatoxin B1 with high sensitivity and specificity has drawn increased attention of studies investigating soybean sauce. A sensitive and rapid quantitative immunochromatographic sensing method was developed for the detection of aflatoxin B1 based on time-resolved fluorescence. It combines the advantages of time-resolved fluorescent sensing and immunochromatography. The dynamic range of a competitive and portable immunoassay was 0.3-10.0 µg·kg(-1), with a limit of detection (LOD) of 0.1 µg·kg(-1) and recoveries of 87.2%-114.3%, within 10 min. The results showed good correlation (R² > 0.99) between time-resolved fluorescent immunochromatographic strip test and high performance liquid chromatography (HPLC). Soybean sauce samples analyzed using time-resolved fluorescent immunochromatographic strip test revealed that 64.2% of samples contained aflatoxin B1 at levels ranging from 0.31 to 12.5 µg·kg(-1). The strip test is a rapid, sensitive, quantitative, and cost-effective on-site screening technique in food safety analysis.

  20. A rapid and robust gradient measurement technique using dynamic single-point imaging.

    Science.gov (United States)

    Jang, Hyungseok; McMillan, Alan B

    2017-09-01

    We propose a new gradient measurement technique based on dynamic single-point imaging (SPI), which allows simple, rapid, and robust measurement of k-space trajectory. To enable gradient measurement, we utilize the variable field-of-view (FOV) property of dynamic SPI, which is dependent on gradient shape. First, one-dimensional (1D) dynamic SPI data are acquired from a targeted gradient axis, and then relative FOV scaling factors between 1D images or k-spaces at varying encoding times are found. These relative scaling factors are the relative k-space position that can be used for image reconstruction. The gradient measurement technique also can be used to estimate the gradient impulse response function for reproducible gradient estimation as a linear time invariant system. The proposed measurement technique was used to improve reconstructed image quality in 3D ultrashort echo, 2D spiral, and multi-echo bipolar gradient-echo imaging. In multi-echo bipolar gradient-echo imaging, measurement of the k-space trajectory allowed the use of a ramp-sampled trajectory for improved acquisition speed (approximately 30%) and more accurate quantitative fat and water separation in a phantom. The proposed dynamic SPI-based method allows fast k-space trajectory measurement with a simple implementation and no additional hardware for improved image quality. Magn Reson Med 78:950-962, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  1. Bulk analysis using nuclear techniques

    International Nuclear Information System (INIS)

    Borsaru, M.; Holmes, R.J.; Mathew, P.J.

    1983-01-01

    Bulk analysis techniques developed for the mining industry are reviewed. Using penetrating neutron and #betta#-radiations, measurements are obtained directly from a large volume of sample (3-30 kg) #betta#-techniques were used to determine the grade of iron ore and to detect shale on conveyor belts. Thermal neutron irradiation was developed for the simultaneous determination of iron and aluminium in iron ore on a conveyor belt. Thermal-neutron activation analysis includes the determination of alumina in bauxite, and manganese and alumina in manganese ore. Fast neutron activation analysis is used to determine silicon in iron ores, and alumina and silica in bauxite. Fast and thermal neutron activation has been used to determine the soil in shredded sugar cane. (U.K.)

  2. Reliability analysis techniques in power plant design

    International Nuclear Information System (INIS)

    Chang, N.E.

    1981-01-01

    An overview of reliability analysis techniques is presented as applied to power plant design. The key terms, power plant performance, reliability, availability and maintainability are defined. Reliability modeling, methods of analysis and component reliability data are briefly reviewed. Application of reliability analysis techniques from a design engineering approach to improving power plant productivity is discussed. (author)

  3. Direct rapid analysis of trace bioavailable soil macronutrients by chemometrics-assisted energy dispersive X-ray fluorescence and scattering spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Kaniu, M.I., E-mail: ikaniu@uonbi.ac.ke [Institute of Nuclear Science and Technology, University of Nairobi, P.O. Box 30197-00100 Nairobi (Kenya); Angeyo, K.H. [Department of Physics, University of Nairobi, P.O. Box 30197-00100 Nairobi (Kenya); Mwala, A.K. [Department of Land Resource Management and Agricultural Technology, University of Nairobi, P.O. Box 30197-00100 Nairobi (Kenya); Mangala, M.J. [Institute of Nuclear Science and Technology, University of Nairobi, P.O. Box 30197-00100 Nairobi (Kenya)

    2012-06-04

    Highlights: Black-Right-Pointing-Pointer Chemometrics-assisted EDXRFS spectroscopy realizes direct, rapid and accurate analysis of trace bioavailable macronutrients in soils. Black-Right-Pointing-Pointer The method is minimally invasive, involves little sample preparation, short analysis times and is relatively insensitive to matrix effects. Black-Right-Pointing-Pointer This opens up the ability to rapidly characterize large number of samples/matrices with this method. - Abstract: Precision agriculture depends on the knowledge and management of soil quality (SQ), which calls for affordable, simple and rapid but accurate analysis of bioavailable soil nutrients. Conventional SQ analysis methods are tedious and expensive. We demonstrate the utility of a new chemometrics-assisted energy dispersive X-ray fluorescence and scattering (EDXRFS) spectroscopy method we have developed for direct rapid analysis of trace 'bioavailable' macronutrients (i.e. C, N, Na, Mg, P) in soils. The method exploits, in addition to X-ray fluorescence, the scatter peaks detected from soil pellets to develop a model for SQ analysis. Spectra were acquired from soil samples held in a Teflon holder analyzed using {sup 109}Cd isotope source EDXRF spectrometer for 200 s. Chemometric techniques namely principal component analysis (PCA), partial least squares (PLS) and artificial neural networks (ANNs) were utilized for pattern recognition based on fluorescence and Compton scatter peaks regions, and to develop multivariate quantitative calibration models based on Compton scatter peak respectively. SQ analyses were realized with high CMD (R{sup 2} > 0.9) and low SEP (0.01% for N and Na, 0.05% for C, 0.08% for Mg and 1.98 {mu}g g{sup -1} for P). Comparison of predicted macronutrients with reference standards using a one-way ANOVA test showed no statistical difference at 95% confidence level. To the best of the authors' knowledge, this is the first time that an XRF method has demonstrated

  4. High resolution melting analysis: a rapid and accurate method to detect CALR mutations.

    Directory of Open Access Journals (Sweden)

    Cristina Bilbao-Sieyro

    Full Text Available The recent discovery of CALR mutations in essential thrombocythemia (ET and primary myelofibrosis (PMF patients without JAK2/MPL mutations has emerged as a relevant finding for the molecular diagnosis of these myeloproliferative neoplasms (MPN. We tested the feasibility of high-resolution melting (HRM as a screening method for rapid detection of CALR mutations.CALR was studied in wild-type JAK2/MPL patients including 34 ET, 21 persistent thrombocytosis suggestive of MPN and 98 suspected secondary thrombocytosis. CALR mutation analysis was performed through HRM and Sanger sequencing. We compared clinical features of CALR-mutated versus 45 JAK2/MPL-mutated subjects in ET.Nineteen samples showed distinct HRM patterns from wild-type. Of them, 18 were mutations and one a polymorphism as confirmed by direct sequencing. CALR mutations were present in 44% of ET (15/34, 14% of persistent thrombocytosis suggestive of MPN (3/21 and none of the secondary thrombocytosis (0/98. Of the 18 mutants, 9 were 52 bp deletions, 8 were 5 bp insertions and other was a complex mutation with insertion/deletion. No mutations were found after sequencing analysis of 45 samples displaying wild-type HRM curves. HRM technique was reproducible, no false positive or negative were detected and the limit of detection was of 3%.This study establishes a sensitive, reliable and rapid HRM method to screen for the presence of CALR mutations.

  5. Development of novel hybrid poly(l-lactide)/chitosan scaffolds using the rapid freeze prototyping technique

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, N; Chen, X B [Division of Biomedical Engineering, University of Saskatchewan, Saskatoon, Saskatchewan (Canada); Li, M G [Department of Mechanical Engineering, University of Saskatchewan, Saskatoon, Saskatchewan (Canada); Cooper, D, E-mail: xbc719@mail.usask.ca [Department of Anatomy and Cell Biology, University of Saskatchewan, Saskatoon, Saskatchewan (Canada)

    2011-09-15

    Engineered scaffolds have been shown to be critical to various tissue engineering applications. This paper presents the development of a novel three-dimensional scaffold made from a mixture of chitosan microspheres (CMs) and poly(l-lactide) by means of the rapid freeze prototyping (RFP) technique. The CMs were used to encapsulate bovine serum albumin (BSA) and improve the scaffold mechanical properties. Experiments to examine the BSA release were carried out; the BSA release could be controlled by adjusting the crosslink degree of the CMs and prolonged after the CMs were embedded into the PLLA scaffolds, while the examination of the mechanical properties of the scaffolds illustrates that they depend on the ratio of CMs to PLLA in the scaffolds as well as the cryogenic temperature used in the RFP fabrication process. The chemical characteristics of the PLLA/chitosan scaffolds were evaluated by Fourier transform infrared (FTIR) spectroscopy. The morphological and pore structure of the scaffolds were also examined by scanning electron microscopy and micro-tomography. The results obtained show that the scaffolds have higher porosity and enhanced pore size distribution compared to those fabricated by the dispensing-based rapid prototyping technique. This study demonstrates that the novel scaffolds have not only enhanced porous structure and mechanical properties but also showed the potential to preserve the bioactivities of the biomolecules and to control the biomolecule distribution and release rate.

  6. Evaluation of nitrate quantification techniques for in-line analysis in drinking water

    International Nuclear Information System (INIS)

    Hernandez Alpizar, Laura; Coy Herrera, Ricardo

    2015-01-01

    The results of a study are presented to determine the potential use of four techniques for the quantification of nitrates in continuous sampling: ion chromatography, ultraviolet absorption spectrophotometry; one table equipment and two mini-spectrophotometers with continuous flow sample injection are used, one for measurements in the field of visible radiation and the other optimized for measurements of ultraviolet radiation absorption. Variables that are considered: reagent and accessory consumption, waste toxicity, analyte response, detection limit (LD), quantification limit (LC), linearity in the field of interest and sensitivity. Ultraviolet absorption detection spectro photometry with continuous flow sample injection is the best of the techniques for line analysis. The response has been between 0-10 mg / L linear, data recommended by WHO for the concentration of nitrates in drinking water. Low consumption of reagents and accessories is shown. This spectrophotometry without hazardous waste generated, has had LD 0.002 mg / L and LC 0.006 mg / L and an adequate sensitivity to respond rapidly to the concentration of the analyte without signal saturation. The desirable characteristics are fulfilled for an on-line analysis system. (author) [es

  7. Coacervative extraction as a green technique for sample preparation for the analysis of organic compounds.

    Science.gov (United States)

    Melnyk, A; Wolska, L; Namieśnik, J

    2014-04-25

    One of the present trends in analytical chemistry is miniaturization, which is one of the methods of green analytical chemistry application. A particular emphasis is placed on the elimination of the use of large amounts of organic solvents which are toxic and harmful to the environment, maintaining high efficiency of the extraction process, high recovery values and low values of quantification (LOQ) and detection (LOD) limits. These requirements are fulfilled by coacervative extraction (CAE) technique. In this review, theoretical aspects of the coacervation process are presented along with environmental and bioanalytical applications of this technique, its advantages, limitations and competitiveness with other techniques. Due to its simplicity and rapidity, CAE is an excellent alternative for currently practiced procedures of sample preparation for the analysis of organic compounds. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Nuclear analysis techniques and environmental sciences

    International Nuclear Information System (INIS)

    1997-10-01

    31 theses are collected in this book. It introduced molecular activation analysis micro-PIXE and micro-probe analysis, x-ray fluorescence analysis and accelerator mass spectrometry. The applications about these nuclear analysis techniques are presented and reviewed for environmental sciences

  9. Rapid analysis method for the determination of 14C specific activity in irradiated graphite.

    Science.gov (United States)

    Remeikis, Vidmantas; Lagzdina, Elena; Garbaras, Andrius; Gudelis, Arūnas; Garankin, Jevgenij; Plukienė, Rita; Juodis, Laurynas; Duškesas, Grigorijus; Lingis, Danielius; Abdulajev, Vladimir; Plukis, Artūras

    2018-01-01

    14C is one of the limiting radionuclides used in the categorization of radioactive graphite waste; this categorization is crucial in selecting the appropriate graphite treatment/disposal method. We propose a rapid analysis method for 14C specific activity determination in small graphite samples in the 1-100 μg range. The method applies an oxidation procedure to the sample, which extracts 14C from the different carbonaceous matrices in a controlled manner. Because this method enables fast online measurement and 14C specific activity evaluation, it can be especially useful for characterizing 14C in irradiated graphite when dismantling graphite moderator and reflector parts, or when sorting radioactive graphite waste from decommissioned nuclear power plants. The proposed rapid method is based on graphite combustion and the subsequent measurement of both CO2 and 14C, using a commercial elemental analyser and the semiconductor detector, respectively. The method was verified using the liquid scintillation counting (LSC) technique. The uncertainty of this rapid method is within the acceptable range for radioactive waste characterization purposes. The 14C specific activity determination procedure proposed in this study takes approximately ten minutes, comparing favorably to the more complicated and time consuming LSC method. This method can be potentially used to radiologically characterize radioactive waste or used in biomedical applications when dealing with the specific activity determination of 14C in the sample.

  10. Rapid analysis method for the determination of 14C specific activity in irradiated graphite.

    Directory of Open Access Journals (Sweden)

    Vidmantas Remeikis

    Full Text Available 14C is one of the limiting radionuclides used in the categorization of radioactive graphite waste; this categorization is crucial in selecting the appropriate graphite treatment/disposal method. We propose a rapid analysis method for 14C specific activity determination in small graphite samples in the 1-100 μg range. The method applies an oxidation procedure to the sample, which extracts 14C from the different carbonaceous matrices in a controlled manner. Because this method enables fast online measurement and 14C specific activity evaluation, it can be especially useful for characterizing 14C in irradiated graphite when dismantling graphite moderator and reflector parts, or when sorting radioactive graphite waste from decommissioned nuclear power plants. The proposed rapid method is based on graphite combustion and the subsequent measurement of both CO2 and 14C, using a commercial elemental analyser and the semiconductor detector, respectively. The method was verified using the liquid scintillation counting (LSC technique. The uncertainty of this rapid method is within the acceptable range for radioactive waste characterization purposes. The 14C specific activity determination procedure proposed in this study takes approximately ten minutes, comparing favorably to the more complicated and time consuming LSC method. This method can be potentially used to radiologically characterize radioactive waste or used in biomedical applications when dealing with the specific activity determination of 14C in the sample.

  11. Statistical evaluation of vibration analysis techniques

    Science.gov (United States)

    Milner, G. Martin; Miller, Patrice S.

    1987-01-01

    An evaluation methodology is presented for a selection of candidate vibration analysis techniques applicable to machinery representative of the environmental control and life support system of advanced spacecraft; illustrative results are given. Attention is given to the statistical analysis of small sample experiments, the quantification of detection performance for diverse techniques through the computation of probability of detection versus probability of false alarm, and the quantification of diagnostic performance.

  12. Rapid development of medical imaging tools with open-source libraries.

    Science.gov (United States)

    Caban, Jesus J; Joshi, Alark; Nagy, Paul

    2007-11-01

    Rapid prototyping is an important element in researching new imaging analysis techniques and developing custom medical applications. In the last ten years, the open source community and the number of open source libraries and freely available frameworks for biomedical research have grown significantly. What they offer are now considered standards in medical image analysis, computer-aided diagnosis, and medical visualization. A cursory review of the peer-reviewed literature in imaging informatics (indeed, in almost any information technology-dependent scientific discipline) indicates the current reliance on open source libraries to accelerate development and validation of processes and techniques. In this survey paper, we review and compare a few of the most successful open source libraries and frameworks for medical application development. Our dual intentions are to provide evidence that these approaches already constitute a vital and essential part of medical image analysis, diagnosis, and visualization and to motivate the reader to use open source libraries and software for rapid prototyping of medical applications and tools.

  13. Techniques for sensitivity analysis of SYVAC results

    International Nuclear Information System (INIS)

    Prust, J.O.

    1985-05-01

    Sensitivity analysis techniques may be required to examine the sensitivity of SYVAC model predictions to the input parameter values, the subjective probability distributions assigned to the input parameters and to the relationship between dose and the probability of fatal cancers plus serious hereditary disease in the first two generations of offspring of a member of the critical group. This report mainly considers techniques for determining the sensitivity of dose and risk to the variable input parameters. The performance of a sensitivity analysis technique may be improved by decomposing the model and data into subsets for analysis, making use of existing information on sensitivity and concentrating sampling in regions the parameter space that generates high doses or risks. A number of sensitivity analysis techniques are reviewed for their application to the SYVAC model including four techniques tested in an earlier study by CAP Scientific for the SYVAC project. This report recommends the development now of a method for evaluating the derivative of dose and parameter value and extending the Kruskal-Wallis technique to test for interactions between parameters. It is also recommended that the sensitivity of the output of each sub-model of SYVAC to input parameter values should be examined. (author)

  14. Techniques involving extreme environment, nondestructive techniques, computer methods in metals research, and data analysis

    International Nuclear Information System (INIS)

    Bunshah, R.F.

    1976-01-01

    A number of different techniques which range over several different aspects of materials research are covered in this volume. They are concerned with property evaluation of 4 0 K and below, surface characterization, coating techniques, techniques for the fabrication of composite materials, computer methods, data evaluation and analysis, statistical design of experiments and non-destructive test techniques. Topics covered in this part include internal friction measurements; nondestructive testing techniques; statistical design of experiments and regression analysis in metallurgical research; and measurement of surfaces of engineering materials

  15. Development of High Speed Imaging and Analysis Techniques Compressible Dynamics Stall

    Science.gov (United States)

    Chandrasekhara, M. S.; Carr, L. W.; Wilder, M. C.; Davis, Sanford S. (Technical Monitor)

    1996-01-01

    Dynamic stall has limited the flight envelope of helicopters for many years. The problem has been studied in the laboratory as well as in flight, but most research, even in the laboratory, has been restricted to surface measurement techniques such as pressure transducers or skin friction gauges, except at low speed. From this research, it became apparent that flow visualization tests performed at Mach numbers representing actual flight conditions were needed if the complex physics associated with dynamic stall was to be properly understood. However, visualization of the flow field during compressible conditions required carefully aligned and meticulously reconstructed holographic interferometry. As part of a long-range effort focused on exposing of the physics of compressible dynamic stall, a research wind tunnel was developed at NASA Ames Research Center which permits visual access to the full flow field surrounding an oscillating airfoil during compressible dynamic stall. Initially, a stroboscopic schlieren technique was used for visualization of the stall process, but the primary research tool has been point diffraction interferometry(PDI), a technique carefully optimized for use in th is project. A review of the process of development of PDI will be presented in the full paper. One of the most valuable aspects of PDI is the fact that interferograms are produced in real time on a continuous basis. The use of a rapidly-pulsed laser makes this practical; a discussion of this approach will be presented in the full paper. This rapid pulsing(up to 40,000 pulses/sec) produces interferograms of the rapidly developing dynamic stall field in sufficient resolution(both in space and time) that the fluid physics of the compressible dynamic stall flowfield can be quantitatively determined, including the gradients of pressure in space and time. This permits analysis of the influence of the effect of pitch rate, Mach number, Reynolds number, amplitude of oscillation, and other

  16. Direct, rapid RNA sequence analysis

    International Nuclear Information System (INIS)

    Peattie, D.A.

    1987-01-01

    The original methods of RNA sequence analysis were based on enzymatic production and chromatographic separation of overlapping oligonucleotide fragments from within an RNA molecule followed by identification of the mononucleotides comprising the oligomer. Over the past decade the field of nucleic acid sequencing has changed dramatically, however, and RNA molecules now can be sequenced in a variety of more streamlined fashions. Most of the more recent advances in RNA sequencing have involved one-dimensional electrophoretic separation of 32 P-end-labeled oligoribonucleotides on polyacrylamide gels. In this chapter the author discusses two of these methods for determining the nucleotide sequences of RNA molecules rapidly: the chemical method and the enzymatic method. Both methods are direct and degradative, i.e., they rely on fragmatic and chemical approaches should be utilized. The single-strand-specific ribonucleases (A, T 1 , T 2 , and S 1 ) provide an efficient means to locate double-helical regions rapidly, and the chemical reactions provide a means to determine the RNA sequence within these regions. In addition, the chemical reactions allow one to assign interactions to specific atoms and to distinguish secondary interactions from tertiary ones. If the RNA molecule is small enough to be sequenced directly by the enzymatic or chemical method, the probing reactions can be done easily at the same time as sequencing reactions

  17. Approaches for the analysis of low molecular weight compounds with laser desorption/ionization techniques and mass spectrometry.

    Science.gov (United States)

    Bergman, Nina; Shevchenko, Denys; Bergquist, Jonas

    2014-01-01

    This review summarizes various approaches for the analysis of low molecular weight (LMW) compounds by different laser desorption/ionization mass spectrometry techniques (LDI-MS). It is common to use an agent to assist the ionization, and small molecules are normally difficult to analyze by, e.g., matrix assisted laser desorption/ionization mass spectrometry (MALDI-MS) using the common matrices available today, because the latter are generally small organic compounds themselves. This often results in severe suppression of analyte peaks, or interference of the matrix and analyte signals in the low mass region. However, intrinsic properties of several LDI techniques such as high sensitivity, low sample consumption, high tolerance towards salts and solid particles, and rapid analysis have stimulated scientists to develop methods to circumvent matrix-related issues in the analysis of LMW molecules. Recent developments within this field as well as historical considerations and future prospects are presented in this review.

  18. Applications of Electromigration Techniques: Applications of Electromigration Techniques in Food Analysis

    Science.gov (United States)

    Wieczorek, Piotr; Ligor, Magdalena; Buszewski, Bogusław

    Electromigration techniques, including capillary electrophoresis (CE), are widely used for separation and identification of compounds present in food products. These techniques may also be considered as alternate and complementary with respect to commonly used analytical techniques, such as high-performance liquid chromatography (HPLC), or gas chromatography (GC). Applications of CE concern the determination of high-molecular compounds, like polyphenols, including flavonoids, pigments, vitamins, food additives (preservatives, antioxidants, sweeteners, artificial pigments) are presented. Also, the method developed for the determination of proteins and peptides composed of amino acids, which are basic components of food products, are studied. Other substances such as carbohydrates, nucleic acids, biogenic amines, natural toxins, and other contaminations including pesticides and antibiotics are discussed. The possibility of CE application in food control laboratories, where analysis of the composition of food and food products are conducted, is of great importance. CE technique may be used during the control of technological processes in the food industry and for the identification of numerous compounds present in food. Due to the numerous advantages of the CE technique it is successfully used in routine food analysis.

  19. Flow analysis techniques for phosphorus: an overview.

    Science.gov (United States)

    Estela, José Manuel; Cerdà, Víctor

    2005-04-15

    A bibliographical review on the implementation and the results obtained in the use of different flow analytical techniques for the determination of phosphorus is carried out. The sources, occurrence and importance of phosphorus together with several aspects regarding the analysis and terminology used in the determination of this element are briefly described. A classification as well as a brief description of the basis, advantages and disadvantages of the different existing flow techniques, namely; segmented flow analysis (SFA), flow injection analysis (FIA), sequential injection analysis (SIA), all injection analysis (AIA), batch injection analysis (BIA), multicommutated FIA (MCFIA), multisyringe FIA (MSFIA) and multipumped FIA (MPFIA) is also carried out. The most relevant manuscripts regarding the analysis of phosphorus by means of flow techniques are herein classified according to the detection instrumental technique used with the aim to facilitate their study and obtain an overall scope. Finally, the analytical characteristics of numerous flow-methods reported in the literature are provided in the form of a table and their applicability to samples with different matrixes, namely water samples (marine, river, estuarine, waste, industrial, drinking, etc.), soils leachates, plant leaves, toothpaste, detergents, foodstuffs (wine, orange juice, milk), biological samples, sugars, fertilizer, hydroponic solutions, soils extracts and cyanobacterial biofilms are tabulated.

  20. Comparison of infrared spectroscopy techniques: developing an efficient method for high resolution analysis of sediment properties from long records

    Science.gov (United States)

    Hahn, Annette; Rosén, Peter; Kliem, Pierre; Ohlendorf, Christian; Persson, Per; Zolitschka, Bernd; Pasado Science Team

    2010-05-01

    The analysis of sediment samples in visible to mid-infrared spectra is ideal for high-resolution records. It requires only small amounts (0.01-0.1g dry weight) of sample material and facilitates rapid and cost efficient analysis of a wide variety of biogeochemical properties on minerogenic and organic substances (Kellner et al. 1998). One of these techniques, the Diffuse Reflectance Fourier Transform Infrared Spectrometry (DRIFTS), has already been successfully applied to lake sediment from very different settings and has shown to be a promising technique for high resolution analyses of long sedimentary records on glacial-interglacial timescales (Rosén et al. 2009). However, the DRIFTS technique includes a time-consuming step where sediment samples are mixed with KBr. To assess if alternative and more rapid infrared (IR) techniques can be used, four different IR spectroscopy techniques are compared for core catcher sediment samples from Laguna Potrok Aike - an ICDP site located in southernmost South America. Partial least square (PLS) calibration models were developed using the DRIFTS technique. The correlation coefficients (R) for correlations between DRIFTS-inferred and conventionally measured biogeochemical properties show values of 0.80 for biogenic silica (BSi), 0.95 for total organic carbon (TOC), 0.91 for total nitrogen (TN), and 0.92 for total inorganic carbon (TIC). Good statistical performance was also obtained by using the Attenuated Total Reflectance Fourier Transform Infrared Spectroscopy ATR-FTIRS technique which requires less sample preparation. Two devices were used, the full-sized Bruker Equinox 252 and the smaller and less expensive Bruker Alpha. R for ATR-FTIRS-inferred and conventionally measured biogeochemical properties were 0.87 (BSi), 0.93 (TOC), 0.90 (TN), and 0.91 (TIC) for the Alpha, and 0.78 (TOC), 0.85 (TN), 0.79 (TIC) for the Equinox 252 device. As the penetration depth of the IR beam is frequency dependent, a firm surface contact of

  1. Simple and rapid analytical method for detection of amino acids in blood using blood spot on filter paper, fast-GC/MS and isotope dilution technique.

    Science.gov (United States)

    Kawana, Shuichi; Nakagawa, Katsuhiro; Hasegawa, Yuki; Yamaguchi, Seiji

    2010-11-15

    A simple and rapid method for quantitative analysis of amino acids, including valine (Val), leucine (Leu), isoleucine (Ile), methionine (Met) and phenylalanine (Phe), in whole blood has been developed using GC/MS. In this method, whole blood was collected using a filter paper technique, and a 1/8 in. blood spot punch was used for sample preparation. Amino acids were extracted from the sample, and the extracts were purified using cation-exchange resins. The isotope dilution method using ²H₈-Val, ²H₃-Leu, ²H₃-Met and ²H₅-Phe as internal standards was applied. Following propyl chloroformate derivatization, the derivatives were analyzed using fast-GC/MS. The extraction recoveries using these techniques ranged from 69.8% to 87.9%, and analysis time for each sample was approximately 26 min. Calibration curves at concentrations from 0.0 to 1666.7 μmol/l for Val, Leu, Ile and Phe and from 0.0 to 333.3 μmol/l for Met showed good linearity with regression coefficients=1. The method detection limits for Val, Leu, Ile, Met and Phe were 24.2, 16.7, 8.7, 1.5 and 12.9 μmol/l, respectively. This method was applied to blood spot samples obtained from patients with phenylketonuria (PKU), maple syrup urine disease (MSUD), hypermethionine and neonatal intrahepatic cholestasis caused by citrin deficiency (NICCD), and the analysis results showed that the concentrations of amino acids that characterize these diseases were increased. These results indicate that this method provides a simple and rapid procedure for precise determination of amino acids in whole blood. Copyright © 2010 Elsevier B.V. All rights reserved.

  2. Evaluation of explicit finite-difference techniques for LMFBR safety analysis

    International Nuclear Information System (INIS)

    Bernstein, D.; Golden, R.D.; Gross, M.B.; Hofmann, R.

    1976-01-01

    In the past few years, the use of explicit finite-difference (EFD) and finite-element computer programs for reactor safety calculations has steadily increased. One of the major areas of application has been for the analysis of hypothetical core disruptive accidents in liquid metal fast breeder reactors. Most of these EFD codes were derived to varying degrees from the same roots, but the codes are large and have progressed rapidly, so there may be substantial differences among them in spite of a common ancestry. When this fact is coupled with the complexity of HCDA calculations, it is not possible to assure that independent calculations of an HCDA will produce substantially the same results. Given the extreme importance of nuclear safety, it is essential to be sure that HCDA analyses are correct, and additional code validation is therefore desirable. A comparative evaluation of HCDA computational techniques is being performed under an ERDA-sponsored program called APRICOT (Analysis of PRImary COntainment Transients). The philosophy, calculations, and preliminary results from this program are described in this paper

  3. PHOTOGRAMMETRIC TECHNIQUES FOR ROAD SURFACE ANALYSIS

    Directory of Open Access Journals (Sweden)

    V. A. Knyaz

    2016-06-01

    Full Text Available The quality and condition of a road surface is of great importance for convenience and safety of driving. So the investigations of the behaviour of road materials in laboratory conditions and monitoring of existing roads are widely fulfilled for controlling a geometric parameters and detecting defects in the road surface. Photogrammetry as accurate non-contact measuring method provides powerful means for solving different tasks in road surface reconstruction and analysis. The range of dimensions concerned in road surface analysis can have great variation from tenths of millimetre to hundreds meters and more. So a set of techniques is needed to meet all requirements of road parameters estimation. Two photogrammetric techniques for road surface analysis are presented: for accurate measuring of road pavement and for road surface reconstruction based on imagery obtained from unmanned aerial vehicle. The first technique uses photogrammetric system based on structured light for fast and accurate surface 3D reconstruction and it allows analysing the characteristics of road texture and monitoring the pavement behaviour. The second technique provides dense 3D model road suitable for road macro parameters estimation.

  4. Improvements to Rapfish: a rapid evaluation technique for fisheries integrating ecological and human dimensions.

    Science.gov (United States)

    Pitcher, T J; Lam, M E; Ainsworth, C; Martindale, A; Nakamura, K; Perry, R I; Ward, T

    2013-10-01

    This paper reports recent developments in Rapfish, a normative, scalable and flexible rapid appraisal technique that integrates both ecological and human dimensions to evaluate the status of fisheries in reference to a norm or goal. Appraisal status targets may be sustainability, compliance with a standard (such as the UN code of conduct for responsible fisheries) or the degree of progress in meeting some other goal or target. The method combines semi-quantitative (e.g. ecological) and qualitative (e.g. social) data via multiple evaluation fields, each of which is assessed through scores assigned to six to 12 attributes or indicators: the scoring method allows user flexibility to adopt a wide range of utility relationships. For assessing sustainability, six evaluation fields have been developed: ecological, technological, economic, social, ethical and institutional. Each field can be assessed directly with a set of scored attributes, or several of the fields can be dealt with in greater detail using nested subfields that themselves comprise multidimensional Rapfish assessments (e.g. the hierarchical institutional field encompasses both governance and management, including a detailed analysis of legality). The user has the choice of including all or only some of the available sustainability fields. For the attributes themselves, there will rarely be quantitative data, but scoring allows these items to be estimated. Indeed, within a normative framework, one important advantage with Rapfish is transparency of the rigour, quality and replicability of the scores. The Rapfish technique employs a constrained multidimensional ordination that is scaled to situate data points within evaluation space. Within each evaluation field, results may be presented as a two-dimensional plot or in a one-dimensional rank order. Uncertainty is expressed through the probability distribution of Monte-Carlo simulations that use the C.L. on each original observation. Overall results of the

  5. How Rapid is Rapid Prototyping? Analysis of ESPADON Programme Results

    Directory of Open Access Journals (Sweden)

    Ian D. Alston

    2003-05-01

    Full Text Available New methodologies, engineering processes, and support environments are beginning to emerge for embedded signal processing systems. The main objectives are to enable defence industry to field state-of-the-art products in less time and with lower costs, including retrofits and upgrades, based predominately on commercial off the shelf (COTS components and the model-year concept. One of the cornerstones of the new methodologies is the concept of rapid prototyping. This is the ability to rapidly and seamlessly move from functional design to the architectural design to the implementation, through automatic code generation tools, onto real-time COTS test beds. In this paper, we try to quantify the term “rapid” and provide results, the metrics, from two independent benchmarks, a radar and sonar beamforming application subset. The metrics show that the rapid prototyping process may be sixteen times faster than a conventional process.

  6. Constrained principal component analysis and related techniques

    CERN Document Server

    Takane, Yoshio

    2013-01-01

    In multivariate data analysis, regression techniques predict one set of variables from another while principal component analysis (PCA) finds a subspace of minimal dimensionality that captures the largest variability in the data. How can regression analysis and PCA be combined in a beneficial way? Why and when is it a good idea to combine them? What kind of benefits are we getting from them? Addressing these questions, Constrained Principal Component Analysis and Related Techniques shows how constrained PCA (CPCA) offers a unified framework for these approaches.The book begins with four concre

  7. Time-series-analysis techniques applied to nuclear-material accounting

    International Nuclear Information System (INIS)

    Pike, D.H.; Morrison, G.W.; Downing, D.J.

    1982-05-01

    This document is designed to introduce the reader to the applications of Time Series Analysis techniques to Nuclear Material Accountability data. Time series analysis techniques are designed to extract information from a collection of random variables ordered by time by seeking to identify any trends, patterns, or other structure in the series. Since nuclear material accountability data is a time series, one can extract more information using time series analysis techniques than by using other statistical techniques. Specifically, the objective of this document is to examine the applicability of time series analysis techniques to enhance loss detection of special nuclear materials. An introductory section examines the current industry approach which utilizes inventory differences. The error structure of inventory differences is presented. Time series analysis techniques discussed include the Shewhart Control Chart, the Cumulative Summation of Inventory Differences Statistics (CUSUM) and the Kalman Filter and Linear Smoother

  8. Phenylketonuria mutation analysis in Northern Ireland: A rapid stepwise approach

    Energy Technology Data Exchange (ETDEWEB)

    Zschocke, J.; Graham, C.A.; Nevin, N.C. [Queen`s Univ., Belfast (Australia)] [and others

    1995-12-01

    We present a multistep approach for the rapid analysis of phenylketonuria (PKU) mutations. In the first step, three common mutations and a polymorphic short tandem repeat (STR) system are rapidly analyzed with a fluorescent multiplex assay. In the second step, minihaplotypes combining STR and VNTR data are used to determine rare mutations likely to be present in an investigated patient, which are then confirmed by restriction enzyme analysis. The remaining mutations are analyzed with denaturant gradient-gel electrophoresis and sequencing. The first two steps together identify both mutations in 90%-95% of PKU patients, and results can be obtained within 2 d. We have investigated 121 Northern Irish families with hyperphenylalaninemia, including virtually all patients born since 1972, and have found 34 different mutations on 241 of the 242 mutant alleles. Three mutations (R408W, 165T, and F39L) account for 57.5% of mutations, while 14 mutations occur with a frequency of 1%-6%. The present analysis system is efficient and inexpensive and is particularly well suited to routine mutation analysis in a diagnostic setting. 19 refs., 5 tabs.

  9. A rapid compression technique for 4-D functional MRI images using data rearrangement and modified binary array techniques.

    Science.gov (United States)

    Uma Vetri Selvi, G; Nadarajan, R

    2015-12-01

    Compression techniques are vital for efficient storage and fast transfer of medical image data. The existing compression techniques take significant amount of time for performing encoding and decoding and hence the purpose of compression is not fully satisfied. In this paper a rapid 4-D lossy compression method constructed using data rearrangement, wavelet-based contourlet transformation and a modified binary array technique has been proposed for functional magnetic resonance imaging (fMRI) images. In the proposed method, the image slices of fMRI data are rearranged so that the redundant slices form a sequence. The image sequence is then divided into slices and transformed using wavelet-based contourlet transform (WBCT). In WBCT, the high frequency sub-band obtained from wavelet transform is further decomposed into multiple directional sub-bands by directional filter bank to obtain more directional information. The relationship between the coefficients has been changed in WBCT as it has more directions. The differences in parent–child relationships are handled by a repositioning algorithm. The repositioned coefficients are then subjected to quantization. The quantized coefficients are further compressed by modified binary array technique where the most frequently occurring value of a sequence is coded only once. The proposed method has been experimented with fMRI images the results indicated that the processing time of the proposed method is less compared to existing wavelet-based set partitioning in hierarchical trees and set partitioning embedded block coder (SPECK) compression schemes [1]. The proposed method could also yield a better compression performance compared to wavelet-based SPECK coder. The objective results showed that the proposed method could gain good compression ratio in maintaining a peak signal noise ratio value of above 70 for all the experimented sequences. The SSIM value is equal to 1 and the value of CC is greater than 0.9 for all

  10. Rapid chemical analysis of allanite

    International Nuclear Information System (INIS)

    Nishiyama, Goro; Hayashi, Hiroshi

    1981-01-01

    Rapid chemical analysis of allanite was studied by atomic absorption spectrophotometry. Powdered sample was fused with mixture of sodium carbonate anhydrous and borax (4 : 1 weight) in platinum crucible and sample solution was prepared. SiO 2 , Fe 2 O 3 , Al 2 O 3 , MnO and rare earth metals were determined by atomic absorption spectrophotometry, CaO, MgO and Ce 2 O 3 by titration, ThO 2 by colorimetry, and La 2 O 3 by flame photometry respectively. For sample solution treated with hydrofluoric acid and sulfuric acid. Na 2 O and K 2 O were determined by atomic absorption spectrophotometry, TiO 2 and P 2 O 5 by colorimetry. Chemical analyses for four samples were carried out and gave consistent results. (author)

  11. Retrospective Study of Rapid-Exchange Monorail Versus Over-the-Wire Technique for Femoropopliteal Angioplasty

    International Nuclear Information System (INIS)

    Jahnke, Thomas; Schaefer, Jost Philipp; Bolte, Hendrik; Schaefer, Fritz; Michalek, Jens; Charalambous, Nicholas; Sapoval, Marc; Mueller-Huelsbeck, Stefan

    2008-01-01

    PurposeThe purpose of this study was to compare procedural outcome of rapid-exchange (RX) monorail versus conventional over-the-wire (OTW) technique for femoropopliteal angioplasty.Materials and MethodsDemographic data, procedure details, angioplasty success, and complications of 328 consecutive percutaneous transluminal angioplasties (PTAs) were collected from a prospective database and retrospectively analyzed. Procedure details included duration of fluoroscopy, area-dose product, amount of contrast agent, sheath sizes, access route, length of stenosis, presence of total occlusion, technical and anatomical success (residual stenosis <30% in the absence of complications), need for bail-out stenting, and periprocedural complications. The RX technique alone was used in 102 of 328 cases (31%); the OTW technique, in 226 of 328 of cases (68%).ResultsTechnical success was 98% for the RX versus 95.4% for the OTW technique (p = 0.2). A significantly greater number of stents had to be implanted due to angioplasty failure when the OTW technique was used (RX, 5.9%; OTW, 13.7%; p = 0.04). There were no significant differences in fluorocopy time, dose-area product, or amount of contrast medium used. The RX system facilitated the use of smaller sheath sizes (5 Fr = 38% and 6 Fr = 59% for RX versus 5 Fr = 16.8% and ≥6 Fr = 82.5% for OTW) but showed only a tendency toward lower overall complication rates (16.6% [17/102] in the RX group versus 19.9% [45/226] in the OTW group; p = 0.09). There was no effect on length of hospitalization. RX monorail systems were not associated with higher procedural costs when compared to conventional OTW technique.ConclusionWe conclude that RX monorail systems seem to enhance the technical success of femoropopliteal angioplasty. Although smaller sheath sizes can be used due to the lower profile of the RX systems, there is only a tendency toward lower complication rates.

  12. A rapid, simple method for the genetic discrimination of intact Arabidopsis thaliana mutant seeds using metabolic profiling by direct analysis in real-time mass spectrometry

    Directory of Open Access Journals (Sweden)

    Jang Young

    2011-06-01

    Full Text Available Abstract Background Efficient high throughput screening systems of useful mutants are prerequisite for study of plant functional genomics and lots of application fields. Advance in such screening tools, thanks to the development of analytic instruments. Direct analysis in real-time (DART-mass spectrometry (MS by ionization of complex materials at atmospheric pressure is a rapid, simple, high-resolution analytical technique. Here we describe a rapid, simple method for the genetic discrimination of intact Arabidopsis thaliana mutant seeds using metabolic profiling by DART-MS. Results To determine whether this DART-MS combined by multivariate analysis can perform genetic discrimination based on global metabolic profiling, intact Arabidopsis thaliana mutant seeds were subjected to DART-MS without any sample preparation. Partial least squares-discriminant analysis (PLS-DA of DART-MS spectral data from intact seeds classified 14 different lines of seeds into two distinct groups: Columbia (Col-0 and Landsberg erecta (Ler ecotype backgrounds. A hierarchical dendrogram based on partial least squares-discriminant analysis (PLS-DA subdivided the Col-0 ecotype into two groups: mutant lines harboring defects in the phenylpropanoid biosynthetic pathway and mutants without these defects. These results indicated that metabolic profiling with DART-MS could discriminate intact Arabidopsis seeds at least ecotype level and metabolic pathway level within same ecotype. Conclusion The described DART-MS combined by multivariate analysis allows for rapid screening and metabolic characterization of lots of Arabidopsis mutant seeds without complex metabolic preparation steps. Moreover, potential novel metabolic markers can be detected and used to clarify the genetic relationship between Arabidopsis cultivars. Furthermore this technique can be applied to predict the novel gene function of metabolic mutants regardless of morphological phenotypes.

  13. Rapid discrimination of bergamot essential oil by paper spray mass spectrometry and chemometric analysis.

    Science.gov (United States)

    Taverna, Domenico; Di Donna, Leonardo; Mazzotti, Fabio; Tagarelli, Antonio; Napoli, Anna; Furia, Emilia; Sindona, Giovanni

    2016-09-01

    A novel approach for the rapid discrimination of bergamot essential oil from other citrus fruits oils is presented. The method was developed using paper spray mass spectrometry (PS-MS) allowing for a rapid molecular profiling coupled with a statistic tool for a precise and reliable discrimination between the bergamot complex matrix and other similar matrices, commonly used for its reconstitution. Ambient mass spectrometry possesses the ability to record mass spectra of ordinary samples, in their native environment, without sample preparation or pre-separation by creating ions outside the instrument. The present study reports a PS-MS method for the determination of oxygen heterocyclic compounds such as furocoumarins, psoralens and flavonoids present in the non-volatile fraction of citrus fruits essential oils followed by chemometric analysis. The volatile fraction of Bergamot is one of the most known and fashionable natural products, which found applications in flavoring industry as ingredient in beverages and flavored foodstuff. The development of the presented method employed bergamot, sweet orange, orange, cedar, grapefruit and mandarin essential oils. PS-MS measurements were carried out in full scan mode for a total run time of 2 min. The capability of PS-MS profiling to act as marker for the classification of bergamot essential oils was evaluated by using multivariate statistical analysis. Two pattern recognition techniques, linear discriminant analysis and soft independent modeling of class analogy, were applied to MS data. The cross-validation procedure has shown excellent results in terms of the prediction ability because both models have correctly classified all samples for each category. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  14. Assessing direct analysis in real-time-mass spectrometry (DART-MS) for the rapid identification of additives in food packaging.

    Science.gov (United States)

    Ackerman, L K; Noonan, G O; Begley, T H

    2009-12-01

    The ambient ionization technique direct analysis in real time (DART) was characterized and evaluated for the screening of food packaging for the presence of packaging additives using a benchtop mass spectrometer (MS). Approximate optimum conditions were determined for 13 common food-packaging additives, including plasticizers, anti-oxidants, colorants, grease-proofers, and ultraviolet light stabilizers. Method sensitivity and linearity were evaluated using solutions and characterized polymer samples. Additionally, the response of a model additive (di-ethyl-hexyl-phthalate) was examined across a range of sample positions, DART, and MS conditions (temperature, voltage and helium flow). Under optimal conditions, molecular ion (M+H+) was the major ion for most additives. Additive responses were highly sensitive to sample and DART source orientation, as well as to DART flow rates, temperatures, and MS inlet voltages, respectively. DART-MS response was neither consistently linear nor quantitative in this setting, and sensitivity varied by additive. All additives studied were rapidly identified in multiple food-packaging materials by DART-MS/MS, suggesting this technique can be used to screen food packaging rapidly. However, method sensitivity and quantitation requires further study and improvement.

  15. Rapid Late Holocene glacier fluctuations reconstructed from South Georgia lake sediments using novel analytical and numerical techniques

    Science.gov (United States)

    van der Bilt, Willem; Bakke, Jostein; Werner, Johannes; Paasche, Øyvind; Rosqvist, Gunhild

    2016-04-01

    The collapse of ice shelves, rapidly retreating glaciers and a dramatic recent temperature increase show that Southern Ocean climate is rapidly shifting. Also, instrumental and modelling data demonstrate transient interactions between oceanic and atmospheric forcings as well as climatic teleconnections with lower-latitude regions. Yet beyond the instrumental period, a lack of proxy climate timeseries impedes our understanding of Southern Ocean climate. Also, available records often lack the resolution and chronological control required to resolve rapid climate shifts like those observed at present. Alpine glaciers are found on most Southern Ocean islands and quickly respond to shifts in climate through changes in mass balance. Attendant changes in glacier size drive variations in the production of rock flour, the suspended product of glacial erosion. This climate response may be captured by downstream distal glacier-fed lakes, continuously recording glacier history. Sediment records from such lakes are considered prime sources for paleoclimate reconstructions. Here, we present the first reconstruction of Late Holocene glacier variability from the island of South Georgia. Using a toolbox of advanced physical, geochemical (XRF) and magnetic proxies, in combination with state-of-the-art numerical techniques, we fingerprinted a glacier signal from glacier-fed lake sediments. This lacustrine sediment signal was subsequently calibrated against mapped glacier extent with the help of geomorphological moraine evidence and remote sensing techniques. The outlined approach enabled us to robustly resolve variations of a complex glacier at sub-centennial timescales, while constraining the sedimentological imprint of other geomorphic catchment processes. From a paleoclimate perspective, our reconstruction reveals a dynamic Late Holocene climate, modulated by long-term shifts in regional circulation patterns. We also find evidence for rapid medieval glacier retreat as well as a

  16. OVERVIEW OF DEVELOPMENT OF P-CARES: PROBABILISTIC COMPUTER ANALYSIS FOR RAPID EVALUATION OF STRUCTURES

    International Nuclear Information System (INIS)

    NIE, J.; XU, J.; COSTANTINO, C.; THOMAS, V.

    2007-01-01

    Brookhaven National Laboratory (BNL) undertook an effort to revise the CARES (Computer Analysis for Rapid Evaluation of Structures) program under the auspices of the US Nuclear Regulatory Commission (NRC). The CARES program provided the NRC staff a capability to quickly check the validity and/or accuracy of the soil-structure interaction (SSI) models and associated data received from various applicants. The aim of the current revision was to implement various probabilistic simulation algorithms in CARES (referred hereinafter as P-CARES [1]) for performing the probabilistic site response and soil-structure interaction (SSI) analyses. This paper provides an overview of the development process of P-CARES, including the various probabilistic simulation techniques used to incorporate the effect of site soil uncertainties into the seismic site response and SSI analyses and an improved graphical user interface (GUI)

  17. Rapid response teams: qualitative analysis of their effectiveness.

    Science.gov (United States)

    Leach, Linda Searle; Mayo, Ann M

    2013-05-01

    Multidisciplinary rapid response teams focus on patients' emergent needs and manage critical situations to prevent avoidable deaths. Although research has focused primarily on outcomes, studies of the actual team effectiveness within the teams from multiple perspectives have been limited. To describe effectiveness of rapid response teams in a large teaching hospital in California that had been using such teams for 5 years. The grounded-theory method was used to discover if substantive theory might emerge from interview and/or observational data. Purposeful sampling was used to conduct in-person semistructured interviews with 17 key informants. Convenience sampling was used for the 9 observed events that involved a rapid response team. Analysis involved use of a concept or indicator model to generate empirical results from the data. Data were coded, compared, and contrasted, and, when appropriate, relationships between concepts were formed. Results Dimensions of effective team performance included the concepts of organizational culture, team structure, expertise, communication, and teamwork. Professionals involved reported that rapid response teams functioned well in managing patients at risk or in crisis; however, unique challenges were identified. Teams were loosely coupled because of the inconsistency of team members from day to day. Team members had little opportunity to develop relationships or team skills. The need for team training may be greater than that among teams that work together regularly under less time pressure to perform. Communication between team members and managing a crisis were critical aspects of an effective response team.

  18. Controlled cooling versus rapid freezing of teratozoospermic semen samples: Impact on sperm chromatin integrity

    Directory of Open Access Journals (Sweden)

    Shivananda N Kalludi

    2011-01-01

    Full Text Available Aim: The present study evaluates the impact of controlled slow cooling and rapid freezing techniques on the sperm chromatin integrity in teratozoospermic and normozoospermic samples. Setting: The study was done in a university infertility clinic, which is a tertiary healthcare center serving the general population. Design: It was a prospective study designed in vitro. Materials and Methods: Semen samples from normozoospermic (N=16 and teratozoospermic (N=13 infertile men were cryopreserved using controlled cooling and rapid freezing techniques. The sperm chromatin integrity was analyzed in fresh and frozen-thawed samples. Statistical Analysis Used: Data were reported as mean and standard error (mean ± SEM of mean. The difference between two techniques was determined by a paired t-test. Results: The freeze-thaw induced chromatin denaturation was significantly (P<0.01 elevated in the post-thaw samples of normozoospermic and teratozoospermic groups. Compared to rapid freezing, there was no difference in the number of red sperms (with DNA damage by the controlled slow cooling method in both normozoospermic and teratozoospermic groups. Freeze-thaw induced sperm chromatin denaturation in teratozoospermic samples did not vary between controlled slow cooling and rapid freezing techniques. Conclusions: Since the controlled slow cooling technique involves the use of expensive instrument and is a time consuming protocol, rapid freezing can be a good alternative technique for teratozoospermic and normozoospermic samples when sperm DNA damage is a concern.

  19. [Fabrication of 3-dimensional skull model with rapid prototyping technique and its primary application in repairing one case of cranio-maxillo-facial trauma].

    Science.gov (United States)

    Xia, Delin; Gui, Lai; Zhang, Zhiyong; Lu, Changsheng; Niu, Feng; Jin, Ji; Liu, Xiaoqing

    2005-10-01

    To investigate the methods of establishing 3-dimensional skull model using electron beam CT (EBCT) data rapid prototyping technique, and to discuss its application in repairing cranio-maxillo-facial trauma. The data were obtained by EBCT continuous volumetric scanning with 1.0 mm slice at thickness. The data were transferred to work-station for 3-dimensional surface reconstruction by computer-aided design software and the images were saved as STL file. The data can be used to control a laser rapid-prototyping device (AFS-320QZ) to construct geometric model. The material for the model construction is a kind of laser-sensitive resin power, which will become a mass when scanned by laser beam. The design and simulation of operation can be done on the model. The image data were transferred to the device slice by slice. Thus a geometric model is constructed according to the image data by repeating this process. Preoperative analysis, surgery simulation and implant of bone defect could be done on this computer-aided manufactured 3D model. One case of cranio-maxillo-facial bone defect resulting from trauma was reconstructed with this method. The EBCT scanning showed that the defect area was 4 cm x 6 cm. The nose was flat and deviated to left. The 3-dimensional skull was reconstructed with EBCT data and rapid prototyping technique. The model can display the structure of 3-dimensional anatomy and their relationship. The prefabricated implant by 3-dimensional model was well-matched with defect. The deformities of flat and deviated nose were corrected. The clinical result was satisfactory after a follow-up of 17 months. The 3-dimensional model of skull can replicate the prototype of disease and play an important role in the diagnosis and simulation of operation for repairing cranio-maxillo-facial trauma.

  20. Rapid fabricating technique for multi-layered human hepatic cell sheets by forceful contraction of the fibroblast monolayer.

    Directory of Open Access Journals (Sweden)

    Yusuke Sakai

    Full Text Available Cell sheet engineering is attracting attention from investigators in various fields, from basic research scientists to clinicians focused on regenerative medicine. However, hepatocytes have a limited proliferation potential in vitro, and it generally takes a several days to form a sheet morphology and multi-layered sheets. We herein report our rapid and efficient technique for generating multi-layered human hepatic cell (HepaRG® cell sheets using pre-cultured fibroblast monolayers derived from human skin (TIG-118 cells as a feeder layer on a temperature-responsive culture dish. Multi-layered TIG-118/HepaRG cell sheets with a thick morphology were harvested on day 4 of culturing HepaRG cells by forceful contraction of the TIG-118 cells, and the resulting sheet could be easily handled. In addition, the human albumin and alpha 1-antitrypsin synthesis activities of TIG-118/HepaRG cells were approximately 1.2 and 1.3 times higher than those of HepaRG cells, respectively. Therefore, this technique is considered to be a promising modality for rapidly fabricating multi-layered human hepatocyte sheets from cells with limited proliferation potential, and the engineered cell sheet could be used for cell transplantation with highly specific functions.

  1. Retrospective study of rapid-exchange monorail versus over-the-wire technique for femoropopliteal angioplasty.

    Science.gov (United States)

    Jahnke, Thomas; Schäfer, Jost Philipp; Bolte, Hendrik; Schäfer, Fritz; Michalek, Jens; Charalambous, Nicholas; Sapoval, Marc; Müller-Hülsbeck, Stefan

    2008-01-01

    The purpose of this study was to compare procedural outcome of rapid-exchange (RX) monorail versus conventional over-the-wire (OTW) technique for femoropopliteal angioplasty. Demographic data, procedure details, angioplasty success, and complications of 328 consecutive percutaneous transluminal angioplasties (PTAs) were collected from a prospective database and retrospectively analyzed. Procedure details included duration of fluoroscopy, area-dose product, amount of contrast agent, sheath sizes, access route, length of stenosis, presence of total occlusion, technical and anatomical success (residual stenosis or = 6 Fr = 82.5% for OTW) but showed only a tendency toward lower overall complication rates (16.6% [17/102] in the RX group versus 19.9% [45/226] in the OTW group; p = 0.09). There was no effect on length of hospitalization. RX monorail systems were not associated with higher procedural costs when compared to conventional OTW technique. We conclude that RX monorail systems seem to enhance the technical success of femoropopliteal angioplasty. Although smaller sheath sizes can be used due to the lower profile of the RX systems, there is only a tendency toward lower complication rates.

  2. Rapid and accurate evaluation of the quality of commercial organic fertilizers using near infrared spectroscopy.

    Directory of Open Access Journals (Sweden)

    Chang Wang

    Full Text Available The composting industry has been growing rapidly in China because of a boom in the animal industry. Therefore, a rapid and accurate assessment of the quality of commercial organic fertilizers is of the utmost importance. In this study, a novel technique that combines near infrared (NIR spectroscopy with partial least squares (PLS analysis is developed for rapidly and accurately assessing commercial organic fertilizers quality. A total of 104 commercial organic fertilizers were collected from full-scale compost factories in Jiangsu Province, east China. In general, the NIR-PLS technique showed accurate predictions of the total organic matter, water soluble organic nitrogen, pH, and germination index; less accurate results of the moisture, total nitrogen, and electrical conductivity; and the least accurate results for water soluble organic carbon. Our results suggested the combined NIR-PLS technique could be applied as a valuable tool to rapidly and accurately assess the quality of commercial organic fertilizers.

  3. Rapid and accurate evaluation of the quality of commercial organic fertilizers using near infrared spectroscopy.

    Science.gov (United States)

    Wang, Chang; Huang, Chichao; Qian, Jian; Xiao, Jian; Li, Huan; Wen, Yongli; He, Xinhua; Ran, Wei; Shen, Qirong; Yu, Guanghui

    2014-01-01

    The composting industry has been growing rapidly in China because of a boom in the animal industry. Therefore, a rapid and accurate assessment of the quality of commercial organic fertilizers is of the utmost importance. In this study, a novel technique that combines near infrared (NIR) spectroscopy with partial least squares (PLS) analysis is developed for rapidly and accurately assessing commercial organic fertilizers quality. A total of 104 commercial organic fertilizers were collected from full-scale compost factories in Jiangsu Province, east China. In general, the NIR-PLS technique showed accurate predictions of the total organic matter, water soluble organic nitrogen, pH, and germination index; less accurate results of the moisture, total nitrogen, and electrical conductivity; and the least accurate results for water soluble organic carbon. Our results suggested the combined NIR-PLS technique could be applied as a valuable tool to rapidly and accurately assess the quality of commercial organic fertilizers.

  4. Gold analysis by the gamma absorption technique

    International Nuclear Information System (INIS)

    Kurtoglu, Arzu; Tugrul, A.B.

    2003-01-01

    Gold (Au) analyses are generally performed using destructive techniques. In this study, the Gamma Absorption Technique has been employed for gold analysis. A series of different gold alloys of known gold content were analysed and a calibration curve was obtained. This curve was then used for the analysis of unknown samples. Gold analyses can be made non-destructively, easily and quickly by the gamma absorption technique. The mass attenuation coefficients of the alloys were measured around the K-shell absorption edge of Au. Theoretical mass attenuation coefficient values were obtained using the WinXCom program and comparison of the experimental results with the theoretical values showed generally good and acceptable agreement

  5. Analysis of Pteridium ribosomal RNA sequences by rapid direct sequencing.

    Science.gov (United States)

    Tan, M K

    1991-08-01

    A total of 864 bases from 5 regions interspersed in the 18S and 26S rRNA molecules from various clones of Pteridium covering the general geographical distribution of the genus was analysed using a rapid rRNA sequencing technique. No base difference has been detected amongst the three major lineages, two of which apparently separated before the breakup of the ancient supercontinent, Pangaea. These regions of the rRNA sequences have thus been conserved for at least 160 million years and are here compared with other eukaryotic, especially plant rRNAs.

  6. INTERNAL ENVIRONMENT ANALYSIS TECHNIQUES

    Directory of Open Access Journals (Sweden)

    Caescu Stefan Claudiu

    2011-12-01

    Full Text Available Theme The situation analysis, as a separate component of the strategic planning, involves collecting and analysing relevant types of information on the components of the marketing environment and their evolution on the one hand and also on the organization’s resources and capabilities on the other. Objectives of the Research The main purpose of the study of the analysis techniques of the internal environment is to provide insight on those aspects that are of strategic importance to the organization. Literature Review The marketing environment consists of two distinct components, the internal environment that is made from specific variables within the organization and the external environment that is made from variables external to the organization. Although analysing the external environment is essential for corporate success, it is not enough unless it is backed by a detailed analysis of the internal environment of the organization. The internal environment includes all elements that are endogenous to the organization, which are influenced to a great extent and totally controlled by it. The study of the internal environment must answer all resource related questions, solve all resource management issues and represents the first step in drawing up the marketing strategy. Research Methodology The present paper accomplished a documentary study of the main techniques used for the analysis of the internal environment. Results The special literature emphasizes that the differences in performance from one organization to another is primarily dependant not on the differences between the fields of activity, but especially on the differences between the resources and capabilities and the ways these are capitalized on. The main methods of analysing the internal environment addressed in this paper are: the analysis of the organizational resources, the performance analysis, the value chain analysis and the functional analysis. Implications Basically such

  7. AAA and AXB algorithms for the treatment of nasopharyngeal carcinoma using IMRT and RapidArc techniques.

    Science.gov (United States)

    Kamaleldin, Maha; Elsherbini, Nader A; Elshemey, Wael M

    2017-09-27

    The aim of this study is to evaluate the impact of anisotropic analytical algorithm (AAA) and 2 reporting systems (AXB-D m and AXB-D w ) of Acuros XB algorithm (AXB) on clinical plans of nasopharyngeal patients using intensity-modulated radiotherapy (IMRT) and RapidArc (RA) techniques. Six plans of different algorithm-technique combinations are performed for 10 patients to calculate dose-volume histogram (DVH) physical parameters for planning target volumes (PTVs) and organs at risk (OARs). The number of monitor units (MUs) and calculation time are also determined. Good coverage is reported for all algorithm-technique combination plans without exceeding the tolerance for OARs. Regardless of the algorithm, RA plans persistently reported higher D 2% values for PTV-70. All IMRT plans reported higher number of MUs (especially with AXB) than did RA plans. AAA-IMRT produced the minimum calculation time of all plans. Major differences between the investigated algorithm-technique combinations are reported only for the number of MUs and calculation time parameters. In terms of these 2 parameters, it is recommended to employ AXB in calculating RA plans and AAA in calculating IMRT plans to achieve minimum calculation times at reduced number of MUs. Copyright © 2017 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

  8. Rapid analysis of formic acid, acetic acid, and furfural in pretreated wheat straw hydrolysates and ethanol in a bioethanol fermentation using atmospheric pressure chemical ionisation mass spectrometry

    Directory of Open Access Journals (Sweden)

    Smart Katherine A

    2011-09-01

    Full Text Available Abstract Atmospheric pressure chemical ionisation mass spectrometry (APCI-MS offers advantages as a rapid analytical technique for the quantification of three biomass degradation products (acetic acid, formic acid and furfural within pretreated wheat straw hydrolysates and the analysis of ethanol during fermentation. The data we obtained using APCI-MS correlated significantly with high-performance liquid chromatography analysis whilst offering the analyst minimal sample preparation and faster sample throughput.

  9. Rapid penetration into granular media visualizing the fundamental physics of rapid earth penetration

    CERN Document Server

    Iskander, Magued

    2015-01-01

    Rapid Penetration into Granular Media: Visualizing the Fundamental Physics of Rapid Earth Penetration introduces readers to the variety of methods and techniques used to visualize, observe, and model the rapid penetration of natural and man-made projectiles into earth materials. It provides seasoned practitioners with a standard reference that showcases the topic's most recent developments in research and application. The text compiles the findings of new research developments on the subject, outlines the fundamental physics of rapid penetration into granular media, and assembles a com

  10. Rapid cloning and bioinformatic analysis of spinach Y chromosome ...

    Indian Academy of Sciences (India)

    Rapid cloning and bioinformatic analysis of spinach Y chromosome- specific EST sequences. Chuan-Liang Deng, Wei-Li Zhang, Ying Cao, Shao-Jing Wang, ... Arabidopsis thaliana mRNA for mitochondrial half-ABC transporter (STA1 gene). 389 2.31E-13. 98.96. SP3−12. Betula pendula histidine kinase 3 (HK3) mRNA, ...

  11. Enabling Rapid and Robust Structural Analysis During Conceptual Design

    Science.gov (United States)

    Eldred, Lloyd B.; Padula, Sharon L.; Li, Wu

    2015-01-01

    This paper describes a multi-year effort to add a structural analysis subprocess to a supersonic aircraft conceptual design process. The desired capabilities include parametric geometry, automatic finite element mesh generation, static and aeroelastic analysis, and structural sizing. The paper discusses implementation details of the new subprocess, captures lessons learned, and suggests future improvements. The subprocess quickly compares concepts and robustly handles large changes in wing or fuselage geometry. The subprocess can rank concepts with regard to their structural feasibility and can identify promising regions of the design space. The automated structural analysis subprocess is deemed robust and rapid enough to be included in multidisciplinary conceptual design and optimization studies.

  12. Porous titanium scaffolds fabricated using a rapid prototyping and powder metallurgy technique.

    Science.gov (United States)

    Ryan, Garrett E; Pandit, Abhay S; Apatsidis, Dimitrios P

    2008-09-01

    One of the main issues in orthopaedic implant design is the fabrication of scaffolds that closely mimic the biomechanical properties of the surrounding bone. This research reports on a multi-stage rapid prototyping technique that was successfully developed to produce porous titanium scaffolds with fully interconnected pore networks and reproducible porosity and pore size. The scaffolds' porous characteristics were governed by a sacrificial wax template, fabricated using a commercial 3D-printer. Powder metallurgy processes were employed to generate the titanium scaffolds by filling around the wax template with titanium slurry. In the attempt to optimise the powder metallurgy technique, variations in slurry concentration, compaction pressure and sintering temperature were investigated. By altering the wax design template, pore sizes ranging from 200 to 400 microm were achieved. Scaffolds with porosities of 66.8 +/- 3.6% revealed compression strengths of 104.4+/-22.5 MPa in the axial direction and 23.5 +/- 9.6 MPa in the transverse direction demonstrating their anisotropic nature. Scaffold topography was characterised using scanning electron microscopy and microcomputed tomography. Three-dimensional reconstruction enabled the main architectural parameters such as pore size, interconnecting porosity, level of anisotropy and level of structural disorder to be determined. The titanium scaffolds were compared to their intended designs, as governed by their sacrificial wax templates. Although discrepancies in architectural parameters existed between the intended and the actual scaffolds, overall the results indicate that the porous titanium scaffolds have the properties to be potentially employed in orthopaedic applications.

  13. Identification of Microorganisms by Modern Analytical Techniques.

    Science.gov (United States)

    Buszewski, Bogusław; Rogowska, Agnieszka; Pomastowski, Paweł; Złoch, Michał; Railean-Plugaru, Viorica

    2017-11-01

    Rapid detection and identification of microorganisms is a challenging and important aspect in a wide range of fields, from medical to industrial, affecting human lives. Unfortunately, classical methods of microorganism identification are based on time-consuming and labor-intensive approaches. Screening techniques require the rapid and cheap grouping of bacterial isolates; however, modern bioanalytics demand comprehensive bacterial studies at a molecular level. Modern approaches for the rapid identification of bacteria use molecular techniques, such as 16S ribosomal RNA gene sequencing based on polymerase chain reaction or electromigration, especially capillary zone electrophoresis and capillary isoelectric focusing. However, there are still several challenges with the analysis of microbial complexes using electromigration technology, such as uncontrolled aggregation and/or adhesion to the capillary surface. Thus, an approach using capillary electrophoresis of microbial aggregates with UV and matrix-assisted laser desorption ionization time-of-flight MS detection is presented.

  14. Multivariate reference technique for quantitative analysis of fiber-optic tissue Raman spectroscopy.

    Science.gov (United States)

    Bergholt, Mads Sylvest; Duraipandian, Shiyamala; Zheng, Wei; Huang, Zhiwei

    2013-12-03

    We report a novel method making use of multivariate reference signals of fused silica and sapphire Raman signals generated from a ball-lens fiber-optic Raman probe for quantitative analysis of in vivo tissue Raman measurements in real time. Partial least-squares (PLS) regression modeling is applied to extract the characteristic internal reference Raman signals (e.g., shoulder of the prominent fused silica boson peak (~130 cm(-1)); distinct sapphire ball-lens peaks (380, 417, 646, and 751 cm(-1))) from the ball-lens fiber-optic Raman probe for quantitative analysis of fiber-optic Raman spectroscopy. To evaluate the analytical value of this novel multivariate reference technique, a rapid Raman spectroscopy system coupled with a ball-lens fiber-optic Raman probe is used for in vivo oral tissue Raman measurements (n = 25 subjects) under 785 nm laser excitation powers ranging from 5 to 65 mW. An accurate linear relationship (R(2) = 0.981) with a root-mean-square error of cross validation (RMSECV) of 2.5 mW can be obtained for predicting the laser excitation power changes based on a leave-one-subject-out cross-validation, which is superior to the normal univariate reference method (RMSE = 6.2 mW). A root-mean-square error of prediction (RMSEP) of 2.4 mW (R(2) = 0.985) can also be achieved for laser power prediction in real time when we applied the multivariate method independently on the five new subjects (n = 166 spectra). We further apply the multivariate reference technique for quantitative analysis of gelatin tissue phantoms that gives rise to an RMSEP of ~2.0% (R(2) = 0.998) independent of laser excitation power variations. This work demonstrates that multivariate reference technique can be advantageously used to monitor and correct the variations of laser excitation power and fiber coupling efficiency in situ for standardizing the tissue Raman intensity to realize quantitative analysis of tissue Raman measurements in vivo, which is particularly appealing in

  15. Rapid Radiochemical Methods for Asphalt Paving Material ...

    Science.gov (United States)

    Technical Brief Validated rapid radiochemical methods for alpha and beta emitters in solid matrices that are commonly encountered in urban environments were previously unavailable for public use by responding laboratories. A lack of tested rapid methods would delay the quick determination of contamination levels and the assessment of acceptable site-specific exposure levels. Of special concern are matrices with rough and porous surfaces, which allow the movement of radioactive material deep into the building material making it difficult to detect. This research focuses on methods that address preparation, radiochemical separation, and analysis of asphalt paving materials and asphalt roofing shingles. These matrices, common to outdoor environments, challenge the capability and capacity of very experienced radiochemistry laboratories. Generally, routine sample preparation and dissolution techniques produce liquid samples (representative of the original sample material) that can be processed using available radiochemical methods. The asphalt materials are especially difficult because they do not readily lend themselves to these routine sample preparation and dissolution techniques. The HSRP and ORIA coordinate radiological reference laboratory priorities and activities in conjunction with HSRP’s Partner Process. As part of the collaboration, the HSRP worked with ORIA to publish rapid radioanalytical methods for selected radionuclides in building material matrice

  16. Elemental analysis techniques using proton microbeam

    International Nuclear Information System (INIS)

    Sakai, Takuro; Oikawa, Masakazu; Sato, Takahiro

    2005-01-01

    Proton microbeam is a powerful tool for two-dimensional elemental analysis. The analysis is based on Particle Induced X-ray Emission (PIXE) and Particle Induced Gamma-ray Emission (PIGE) techniques. The paper outlines the principles and instruments, and describes the dental application has been done in JAERI Takasaki. (author)

  17. Direct typing of Canine parvovirus (CPV) from infected dog faeces by rapid mini sequencing technique.

    Science.gov (United States)

    V, Pavana Jyothi; S, Akila; Selvan, Malini K; Naidu, Hariprasad; Raghunathan, Shwethaa; Kota, Sathish; Sundaram, R C Raja; Rana, Samir Kumar; Raj, G Dhinakar; Srinivasan, V A; Mohana Subramanian, B

    2016-12-01

    Canine parvovirus (CPV) is a non-enveloped single stranded DNA virus with an icosahedral capsid. Mini-sequencing based CPV typing was developed earlier to detect and differentiate all the CPV types and FPV in a single reaction. This technique was further evaluated in the present study by performing the mini-sequencing directly from fecal samples which avoided tedious virus isolation steps by cell culture system. Fecal swab samples were collected from 84 dogs with enteritis symptoms, suggestive of parvoviral infection from different locations across India. Seventy six of these samples were positive by PCR; the subsequent mini-sequencing reaction typed 74 of them as type 2a virus, and 2 samples as type 2b. Additionally, 25 of the positive samples were typed by cycle sequencing of PCR products. Direct CPV typing from fecal samples using mini-sequencing showed 100% correlation with CPV typing by cycle sequencing. Moreover, CPV typing was achieved by mini-sequencing even with faintly positive PCR amplicons which was not possible by cycle sequencing. Therefore, the mini-sequencing technique is recommended for regular epidemiological follow up of CPV types, since the technique is rapid, highly sensitive and high capacity method for CPV typing. Copyright © 2016. Published by Elsevier B.V.

  18. Rapid prenatal diagnosis of cytogenetic abnormalities by array CGH analysis

    Science.gov (United States)

    Array CGH analysis has been shown to be highly accurate for rapid detection of chromosomal aneuploidies and submicroscopic deletions or duplications on fetal DNA samples in a clinical prenatal diagnostic setting. The objective of this study is to present our "post-validation phase" experience with ...

  19. Development of evaluation method for software safety analysis techniques

    International Nuclear Information System (INIS)

    Huang, H.; Tu, W.; Shih, C.; Chen, C.; Yang, W.; Yih, S.; Kuo, C.; Chen, M.

    2006-01-01

    Full text: Full text: Following the massive adoption of digital Instrumentation and Control (I and C) system for nuclear power plant (NPP), various Software Safety Analysis (SSA) techniques are used to evaluate the NPP safety for adopting appropriate digital I and C system, and then to reduce risk to acceptable level. However, each technique has its specific advantage and disadvantage. If the two or more techniques can be complementarily incorporated, the SSA combination would be more acceptable. As a result, if proper evaluation criteria are available, the analyst can then choose appropriate technique combination to perform analysis on the basis of resources. This research evaluated the applicable software safety analysis techniques nowadays, such as, Preliminary Hazard Analysis (PHA), Failure Modes and Effects Analysis (FMEA), Fault Tree Analysis (FTA), Markov chain modeling, Dynamic Flowgraph Methodology (DFM), and simulation-based model analysis; and then determined indexes in view of their characteristics, which include dynamic capability, completeness, achievability, detail, signal/ noise ratio, complexity, and implementation cost. These indexes may help the decision makers and the software safety analysts to choose the best SSA combination arrange their own software safety plan. By this proposed method, the analysts can evaluate various SSA combinations for specific purpose. According to the case study results, the traditional PHA + FMEA + FTA (with failure rate) + Markov chain modeling (without transfer rate) combination is not competitive due to the dilemma for obtaining acceptable software failure rates. However, the systematic architecture of FTA and Markov chain modeling is still valuable for realizing the software fault structure. The system centric techniques, such as DFM and Simulation-based model analysis, show the advantage on dynamic capability, achievability, detail, signal/noise ratio. However, their disadvantage are the completeness complexity

  20. Analysis of archaeological pieces with nuclear techniques

    International Nuclear Information System (INIS)

    Tenorio, D.

    2002-01-01

    In this work nuclear techniques such as Neutron Activation Analysis, PIXE, X-ray fluorescence analysis, Metallography, Uranium series, Rutherford Backscattering for using in analysis of archaeological specimens and materials are described. Also some published works and thesis about analysis of different Mexican and Meso american archaeological sites are referred. (Author)

  1. Comparison of laser fluorimetry, high resolution gamma-ray spectrometry and neutron activation analysis techniques for determination of uranium content in soil samples

    International Nuclear Information System (INIS)

    Ghods, A.; Asgharizadeh, F.; Salimi, B.; Abbasi, A.

    2004-01-01

    Much more concern is given nowadays for exposure of the world population to natural radiation especially to uranium since 57% of that exposure is due to radon-222, which is a member of uranium decay series. Most of the methods used for uranium determination is low concentration require either tedious separation and preconcentration or the accessibility to special instrumentation for detection of uranium at this low level. this study compares three techniques and methods for uranium analysis among different soil sample with variable uranium contents. Two of these techniques, neutron activation analysis and high resolution gamma-ray spectrometry , are non-destructive while the other, laser fluorimetry is done via chemical extraction of uranium. Analysis of standard materials is done also to control the quality and accuracy of the work. In spite of having quite variable ranges of detection limit, results obtained by high resolution gamma-ray spectrometry based on the assumption of having secular equilibrium between uranium and its daughters, which causes deviation whenever this condition was missed. For samples with reasonable uranium content, neutron activation analysis would be a rapid and reliable technique, while for low uranium content laser fluorimetry would be the most appropriate and accurate technique

  2. Recently-developed neutron activation analysis techniques utilizing the University of California at Irvine TRIGA Mark I reactor

    International Nuclear Information System (INIS)

    Guinn, V.P.; Chambless, D.; Cortes T, E.; DeLancey, K.; Garzonov, E.; Miller, D.A.; Miller, G.E.; Purcell, M.A.

    1976-01-01

    The University of California at Irvine (UCI) 250 kW TRIGA Mark I reactor is used extensively for neutron activation analysis (NAA) studies. These particularly include basic technique studies and application studies in the fields of environmental pollution, crime investigation, archaeology, oceanography, and geochemistry. In recent NAA studies at UCI, a number of techniques have been developed which considerably improve the usefulness of such a research reactor for NAA work, and which should be of interest and use to others. Six of these techniques will be described in further detail in the full paper. They are as follows: development and use of (1) an automated high-precision rapid transfer system for instrumental NAA measurements with induced activities having half lives as short as 0.5 second, (2) an automated measurement system and computer program for making accurate dead-time corrections under conditions where the Ge(Li) spectrometer deadtime is changing rapidly during the counting period, (3) a technique to minimize the loss of mercury from samples during reactor irradiation via the use of dry-ice-packed, vented TRIGA rotary rack tubes, (4) a technique for compacting powdered samples, by pre-irradiation treatment with a solution of paraffin in carbon disulfide, to provide reproducible irradiation and counting geometries, (5) a method utilizing hydrated antimony pentoxide (HAP) as a pre-irradiation treatment material for removal of sodium from aqueous and wet-ashed samples, and (6) a computerized system for predicting in advance of activation, from approximate known elemental compositions, the total counting rate, deadtime, spectrum shape, principal photopeaks, and approximate actual lower limits of instrumental NAA detection of designated elements for any selected irradiation and decay times. (author)

  3. Comparing rapid methods for detecting Listeria in seafood and environmental samples using the most probably number (MPN) technique.

    Science.gov (United States)

    Cruz, Cristina D; Win, Jessicah K; Chantarachoti, Jiraporn; Mutukumira, Anthony N; Fletcher, Graham C

    2012-02-15

    The standard Bacteriological Analytical Manual (BAM) protocol for detecting Listeria in food and on environmental surfaces takes about 96 h. Some studies indicate that rapid methods, which produce results within 48 h, may be as sensitive and accurate as the culture protocol. As they only give presence/absence results, it can be difficult to compare the accuracy of results generated. We used the Most Probable Number (MPN) technique to evaluate the performance and detection limits of six rapid kits for detecting Listeria in seafood and on an environmental surface compared with the standard protocol. Three seafood products and an environmental surface were inoculated with similar known cell concentrations of Listeria and analyzed according to the manufacturers' instructions. The MPN was estimated using the MPN-BAM spreadsheet. For the seafood products no differences were observed among the rapid kits and efficiency was similar to the BAM method. On the environmental surface the BAM protocol had a higher recovery rate (sensitivity) than any of the rapid kits tested. Clearview™, Reveal®, TECRA® and VIDAS® LDUO detected the cells but only at high concentrations (>10(2) CFU/10 cm(2)). Two kits (VIP™ and Petrifilm™) failed to detect 10(4) CFU/10 cm(2). The MPN method was a useful tool for comparing the results generated by these presence/absence test kits. There remains a need to develop a rapid and sensitive method for detecting Listeria in environmental samples that performs as well as the BAM protocol, since none of the rapid tests used in this study achieved a satisfactory result. Copyright © 2011 Elsevier B.V. All rights reserved.

  4. The DNA 'comet assay' as a rapid screening technique to control irradiated food

    International Nuclear Information System (INIS)

    Cerda, H.; Delincee, H.; Haine, H.; Rupp, H.

    1997-01-01

    The exposure of food to ionizing radiation is being progressively used in many countries to inactivate food pathogens, to eradicate pests, and to extend shelf-life, thereby contributing to a safer and more plentiful food supply. To ensure free consumer choice, irradiated food will be labelled as such, and to enforce labelling, analytical methods to detect the irradiation treatment in the food product itself are desirable. In particular, there is a need for simple and rapid screening methods for the control of irradiated food. The DNA comet assay offers great potential as a rapid tool to detect whether a wide variety of foodstuffs have been radiation processed. In order to simplify the test, the agarose single-layer set-up has been chosen, using a neutral protocol. Interlaboratory blind trials have been successfully carried out with a number of food products, both of animal and plant origin. This paper presents an overview of the hitherto obtained results and in addition the results of an intercomparison test with seeds, dried fruits and spices are described. In this intercomparison, an identification rate of 95% was achieved. Thus, using this novel technique, an effective screening of radiation-induced DNA fragmentation is obtained. Since other food treatments also may cause DNA fragmentation, samples with fragmented DNA suspected to have been irradiated should be analyzed by other validated methods for irradiated food, if such treatments which damage DNA cannot be excluded

  5. Advanced Techniques of Stress Analysis

    Directory of Open Access Journals (Sweden)

    Simion TATARU

    2013-12-01

    Full Text Available This article aims to check the stress analysis technique based on 3D models also making a comparison with the traditional technique which utilizes a model built directly into the stress analysis program. This comparison of the two methods will be made with reference to the rear fuselage of IAR-99 aircraft, structure with a high degree of complexity which allows a meaningful evaluation of both approaches. Three updated databases are envisaged: the database having the idealized model obtained using ANSYS and working directly on documentation, without automatic generation of nodes and elements (with few exceptions, the rear fuselage database (performed at this stage obtained with Pro/ ENGINEER and the one obtained by using ANSYS with the second database. Then, each of the three databases will be used according to arising necessities.The main objective is to develop the parameterized model of the rear fuselage using the computer aided design software Pro/ ENGINEER. A review of research regarding the use of virtual reality with the interactive analysis performed by the finite element method is made to show the state- of- the-art achieved in this field.

  6. Using molecular techniques for rapid detection of Salmonella ...

    African Journals Online (AJOL)

    PRECIOUS

    2010-02-01

    Feb 1, 2010 ... A total of 152 samples of chicken and chicken products ... detection of Salmonella species in the collected field samples ... that 16 million new cases of typhoid fever occur each ... vative methods for the rapid identification of Salmonella ... saved for the PCR-Non Selective test (PCR-NS) and 1 ml of the.

  7. Direct rapid analysis of trace bioavailable soil macronutrients by chemometrics-assisted energy dispersive X-ray fluorescence and scattering spectrometry.

    Science.gov (United States)

    Kaniu, M I; Angeyo, K H; Mwala, A K; Mangala, M J

    2012-06-04

    Precision agriculture depends on the knowledge and management of soil quality (SQ), which calls for affordable, simple and rapid but accurate analysis of bioavailable soil nutrients. Conventional SQ analysis methods are tedious and expensive. We demonstrate the utility of a new chemometrics-assisted energy dispersive X-ray fluorescence and scattering (EDXRFS) spectroscopy method we have developed for direct rapid analysis of trace 'bioavailable' macronutrients (i.e. C, N, Na, Mg, P) in soils. The method exploits, in addition to X-ray fluorescence, the scatter peaks detected from soil pellets to develop a model for SQ analysis. Spectra were acquired from soil samples held in a Teflon holder analyzed using (109)Cd isotope source EDXRF spectrometer for 200 s. Chemometric techniques namely principal component analysis (PCA), partial least squares (PLS) and artificial neural networks (ANNs) were utilized for pattern recognition based on fluorescence and Compton scatter peaks regions, and to develop multivariate quantitative calibration models based on Compton scatter peak respectively. SQ analyses were realized with high CMD (R(2)>0.9) and low SEP (0.01% for N and Na, 0.05% for C, 0.08% for Mg and 1.98 μg g(-1) for P). Comparison of predicted macronutrients with reference standards using a one-way ANOVA test showed no statistical difference at 95% confidence level. To the best of the authors' knowledge, this is the first time that an XRF method has demonstrated utility in trace analysis of macronutrients in soil or related matrices. Copyright © 2012 Elsevier B.V. All rights reserved.

  8. A new analysis technique for microsamples

    International Nuclear Information System (INIS)

    Boyer, R.; Journoux, J.P.; Duval, C.

    1989-01-01

    For many decades, isotopic analysis of Uranium or Plutonium has been performed by mass spectrometry. The most recent analytical techniques, using the counting method or a plasma torch combined with a mass spectrometer (ICP.MS) have not yet to reach a greater degree of precision than the older methods in this field. The two means of ionization for isotopic analysis - by electronic bombardment of atoms or molecules (source of gas ions) and - by thermal effect (thermoionic source) are compared revealing some inconsistency between the quantity of sample necessary for analysis and the luminosity. In fact, the quantity of sample necessary for the gas source mass spectrometer is 10 to 20 times greater than that for the thermoionization spectrometer, while the sample consumption is between 10 5 to 10 6 times greater. This proves that almost the entire sample is not necessary for the measurement; it is only required because of the system of introduction for the gas spectrometer. The new analysis technique referred to as ''Microfluorination'' corrects this anomaly and exploits the advantages of the electron bombardment method of ionization

  9. Handbook of Qualitative Research Techniques and Analysis in Entrepreneurship

    DEFF Research Database (Denmark)

    One of the most challenging tasks in the research design process is choosing the most appropriate data collection and analysis techniques. This Handbook provides a detailed introduction to five qualitative data collection and analysis techniques pertinent to exploring entreprneurial phenomena....

  10. The utilization of cranial models created using rapid prototyping techniques in the development of models for navigation training.

    Science.gov (United States)

    Waran, V; Pancharatnam, Devaraj; Thambinayagam, Hari Chandran; Raman, Rajagopal; Rathinam, Alwin Kumar; Balakrishnan, Yuwaraj Kumar; Tung, Tan Su; Rahman, Z A

    2014-01-01

    Navigation in neurosurgery has expanded rapidly; however, suitable models to train end users to use the myriad software and hardware that come with these systems are lacking. Utilizing three-dimensional (3D) industrial rapid prototyping processes, we have been able to create models using actual computed tomography (CT) data from patients with pathology and use these models to simulate a variety of commonly performed neurosurgical procedures with navigation systems. To assess the possibility of utilizing models created from CT scan dataset obtained from patients with cranial pathology to simulate common neurosurgical procedures using navigation systems. Three patients with pathology were selected (hydrocephalus, right frontal cortical lesion, and midline clival meningioma). CT scan data following an image-guidance surgery protocol in DIACOM format and a Rapid Prototyping Machine were taken to create the necessary printed model with the corresponding pathology embedded. The ability in registration, planning, and navigation of two navigation systems using a variety of software and hardware provided by these platforms was assessed. We were able to register all models accurately using both navigation systems and perform the necessary simulations as planned. Models with pathology utilizing 3D rapid prototyping techniques accurately reflect data of actual patients and can be used in the simulation of neurosurgical operations using navigation systems. Georg Thieme Verlag KG Stuttgart · New York.

  11. Quality assurance techniques for activation analysis

    International Nuclear Information System (INIS)

    Becker, D.A.

    1984-01-01

    The principles and techniques of quality assurance are applied to the measurement method of activation analysis. Quality assurance is defined to include quality control and quality assessment. Plans for quality assurance include consideration of: personnel; facilities; analytical design; sampling and sample preparation; the measurement process; standards; and documentation. Activation analysis concerns include: irradiation; chemical separation; counting/detection; data collection, and analysis; and calibration. Types of standards discussed include calibration materials and quality assessment materials

  12. Rapid and sensitive ultrasonic-assisted derivatisation microextraction (UDME) technique for bitter taste-free amino acids (FAA) study by HPLC-FLD.

    Science.gov (United States)

    Chen, Guang; Li, Jun; Sun, Zhiwei; Zhang, Shijuan; Li, Guoliang; Song, Cuihua; Suo, Yourui; You, Jinmao

    2014-01-15

    Amino acids, as the main contributors to taste, are usually found in relatively high levels in bitter foods. In this work, we focused on seeking a rapid, sensitive and simple method to determine FAA for large batches of micro-samples and to explore the relationship between FAA and bitterness. Overall condition optimisation indicated that the new UDME technique offered higher derivatisation yields and extraction efficiencies than traditional methods. Only 35min was needed in the whole operation process. Very low LLOQ (Lower limit of quantification: 0.21-5.43nmol/L) for FAA in twelve bitter foods was obtained, with which BTT (bitter taste thresholds) and CABT (content of FAA at BTT level) were newly determined. The ratio of CABT to BTT increased with decreasing of BTT. This work provided powerful potential for the high-throughput trace analysis of micro-sample and also a methodology to study the relationship between the chemical constituents and the taste. Copyright © 2013 Elsevier Ltd. All rights reserved.

  13. Rapid determination of phenol content in extra virgin olive oil

    Directory of Open Access Journals (Sweden)

    Favati, F.

    1994-04-01

    Full Text Available A quick extraction methodology was developed to reduce the time usually required to determine the phenol content in olive oil. The validity of this method, based on SPE technique, was tested against two other phenol extraction techniques.
    The statistical analysis of the analytical data showed that over a phenol content range of 110-550 μg/g oil, the proposed method can be a reliable alternative for a rapid extraction of the phenols from olive oil.

    No disponible.

  14. Effectiveness Analysis of a Part-Time Rapid Response System During Operation Versus Nonoperation.

    Science.gov (United States)

    Kim, Youlim; Lee, Dong Seon; Min, Hyunju; Choi, Yun Young; Lee, Eun Young; Song, Inae; Park, Jong Sun; Cho, Young-Jae; Jo, You Hwan; Yoon, Ho Il; Lee, Jae Ho; Lee, Choon-Taek; Do, Sang Hwan; Lee, Yeon Joo

    2017-06-01

    To evaluate the effect of a part-time rapid response system on the occurrence rate of cardiopulmonary arrest by comparing the times of rapid response system operation versus nonoperation. Retrospective cohort study. A 1,360-bed tertiary care hospital. Adult patients admitted to the general ward were screened. Data were collected over 36 months from rapid response system implementation (October 2012 to September 2015) and more than 45 months before rapid response system implementation (January 2009 to September 2012). None. The rapid response system operates from 7 AM to 10 PM on weekdays and from 7 AM to 12 PM on Saturdays. Primary outcomes were the difference of cardiopulmonary arrest incidence between pre-rapid response system and post-rapid response system periods and whether the rapid response system operating time affects the cardiopulmonary arrest incidence. The overall cardiopulmonary arrest incidence (per 1,000 admissions) was 1.43. Although the number of admissions per month and case-mix index were increased (3,555.18 vs 4,564.72, p times (0.82 vs 0.49/1,000 admissions; p = 0.001) but remained similar during rapid response system nonoperating times (0.77 vs 0.73/1,000 admissions; p = 0.729). The implementation of a part-time rapid response system reduced the cardiopulmonary arrest incidence based on the reduction of cardiopulmonary arrest during rapid response system operating times. Further analysis of the cost effectiveness of part-time rapid response system is needed.

  15. Protein folding kinetics by combined use of rapid mixing techniques and NMR observation of individual amide protons

    International Nuclear Information System (INIS)

    Roder, H.; Wuethrich, K.

    1986-01-01

    A method to be used for experimental studies of protein folding introduced by Schmid and Baldwin, which is based on the competition between amide hydrogen exchange and protein refolding, was extended by using rapid mixing techniques and 1 H NMR to provide site-resolved kinetic information on the early phases of protein structure acquisition. In this method, a protonated solution of the unfolded protein is rapidly mixed with a deuterated buffer solution at conditions assuring protein refolding in the mixture. This simultaneously initiates the exchange of unprotected amide protons with solvent deuterium and the refolding of protein segments which can protect amide groups from further exchange. After variable reaction times the amide proton exchange is quenched while folding to the native form continues to completion. By using 1 H NMR, the extent of exchange at individual amide sites is then measured in the refolded protein. Competition experiments at variable reaction times or variable pH indicate the time at which each amide group is protected in the refolding process. This technique was applied to the basic pancreatic trypsin inhibitor, for which sequence-specific assignments of the amide proton NMR lines had previously been obtained. For eight individual amide protons located in the beta-sheet and the C-terminal alpha-helix of this protein, apparent refolding rates in the range from 15 s-1 to 60 s-1 were observed. These rates are on the time scale of the fast folding phase observed with optical probes

  16. P-CARES 2.0.0, Probabilistic Computer Analysis for Rapid Evaluation of Structures

    International Nuclear Information System (INIS)

    2008-01-01

    1 - Description of program or function: P-CARES 2.0.0 (Probabilistic Computer Analysis for Rapid Evaluation of Structures) was developed for NRC staff use to determine the validity and accuracy of the analysis methods used by various utilities for structural safety evaluations of nuclear power plants. P-CARES provides the capability to effectively evaluate the probabilistic seismic response using simplified soil and structural models and to quickly check the validity and/or accuracy of the SSI data received from applicants and licensees. The code is organized in a modular format with the basic modules of the system performing static, seismic, and nonlinear analysis. 2 - Methods: P-CARES is an update of the CARES program developed at Brookhaven National Laboratory during the 1980's. A major improvement is the enhanced analysis capability in which a probabilistic algorithm has been implemented to perform the probabilistic site response and soil-structure interaction (SSI) analyses. This is accomplished using several sampling techniques such as the Latin Hypercube sampling (LHC), engineering LHC, the Fekete Point Set method, and also the traditional Monte Carlo simulation. This new feature enhances the site response and SSI analysis such that the effect of uncertainty in local site soil properties can now be quantified. Another major addition to P-CARES is a graphical user interface (GUI) which significantly improves the performance of P-Cares in terms of the inter-relations among different functions of the program, and facilitates the input/output processing and execution management. It also provides many user friendly features that would allow an analyst to quickly develop insights from the analysis results. 3 - Restrictions on the complexity of the problem: None noted

  17. Sensitive rapid analysis of iodine-labelled protein mixture on flat substrates with high spatial resolution

    International Nuclear Information System (INIS)

    Zanevskij, Yu.V.; Ivanov, A.B.; Movchan, S.A.; Peshekhonov, V.D.; Chan Dyk Tkhan'; Chernenko, S.P.; Kaminir, L.B.; Krejndlin, Eh.Ya.; Chernyj, A.A.

    1983-01-01

    Usability of rapid analysis by electrophoresis of the admixture of I 125 -labelled proteins on flat samples by means of URAN type installation developed using a multiwire proportional chamber is studied. The sensitivity of the method is better than 200 cpm/cm 2 and the spatial resolution is approximately 1 mm. The procedure of the rapid analysis is no longer than several tens of minutes

  18. Techniques for the thermal/hydraulic analysis of LMFBR check valves

    International Nuclear Information System (INIS)

    Cho, S.M.; Kane, R.S.

    1979-01-01

    A thermal/hydraulic analysis of the check valves in liquid sodium service for LMFBR plants is required to provide temperature data for thermal stress analysis of the valves for specified transient conditions. Because of the complex three-dimensional flow pattern within the valve, the heat transfer analysis techniques for less complicated shapes could not be used. This paper discusses the thermal analysis techniques used to assure that the valve stress analysis is conservative. These techniques include a method for evaluating the recirculating flow patterns and for selecting appropriately conservative heat transfer correlations in various regions of the valve

  19. A fractal analysis of skin pigmented lesions using the novel tool of the variogram technique

    Energy Technology Data Exchange (ETDEWEB)

    Mastrolonardo, Mario [Department of Medical and Occupational Sciences, Unit of Dermatology, Azienda Ospedaliero-Universitaria ' Ospedali Riuniti' di Foggia (Italy)]. E-mail: mariomastrolonardo@libero.it; Conte, Elio [Department of Medical and Occupational Sciences, Unit of Dermatology, Azienda Ospedaliero-Universitaria ' Ospedali Riuniti' di Foggia (Italy); Department of Pharmacology and Human Physiology, TIRES-Center for Innovative Technology for Signal Detection and Processing, Bari University, 70100 Bari (Italy); Zbilut, Joseph P. [Department of Molecular Biophysics and Physiology, Rush University, Chicago, IL 60612 (United States)

    2006-06-15

    The incidence of the cutaneous malignant melanoma is increasing rapidly in the world [Ferlay J, Bray F, Pisani P, et al. GLOBOCAN 2000: Cancer incidence, mortality and prevalence worldwide, Version 1.0 IARC Cancer Base no. 5. Lyon: IARC Press, 2001]. The therapeutic address requires a method having high sensitivity and capability to diagnose such disease at an early stage. We introduce a new diagnostic method based on non-linear methodologies. In detail we suggest that fractal as well as noise and chaos dynamics are the most important components responsible for genetic instability of melanocytes. As consequence we introduce the new technique of the variogram and of fractal analysis extended to the whole regions of interest of skin in order to obtain parameters able to identify the malignant lesion. In a preliminary analysis, satisfactory results are reached.

  20. Microextraction sample preparation techniques in biomedical analysis.

    Science.gov (United States)

    Szultka, Malgorzata; Pomastowski, Pawel; Railean-Plugaru, Viorica; Buszewski, Boguslaw

    2014-11-01

    Biologically active compounds are found in biological samples at relatively low concentration levels. The sample preparation of target compounds from biological, pharmaceutical, environmental, and food matrices is one of the most time-consuming steps in the analytical procedure. The microextraction techniques are dominant. Metabolomic studies also require application of proper analytical technique for the determination of endogenic metabolites present in biological matrix on trace concentration levels. Due to the reproducibility of data, precision, relatively low cost of the appropriate analysis, simplicity of the determination, and the possibility of direct combination of those techniques with other methods (combination types on-line and off-line), they have become the most widespread in routine determinations. Additionally, sample pretreatment procedures have to be more selective, cheap, quick, and environmentally friendly. This review summarizes the current achievements and applications of microextraction techniques. The main aim is to deal with the utilization of different types of sorbents for microextraction and emphasize the use of new synthesized sorbents as well as to bring together studies concerning the systematic approach to method development. This review is dedicated to the description of microextraction techniques and their application in biomedical analysis. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Analysis of deployment techniques for webbased applications in SMEs

    OpenAIRE

    Browne, Cathal

    2011-01-01

    The Internet is no longer just a source for accessing information; it has become a valuable medium for social networking and software services. Web-browsers can now access entire software systems available online to provide the user with a range of services. The concept of software as a service(SAAS) was born out of this. The number of development techniques and frameworks for such web-applications has grown rapidly and much research and development has been carried out on adva...

  2. The Advanced Rapid Imaging and Analysis (ARIA) Project: Status of SAR products for Earthquakes, Floods, Volcanoes and Groundwater-related Subsidence

    Science.gov (United States)

    Owen, S. E.; Yun, S. H.; Hua, H.; Agram, P. S.; Liu, Z.; Sacco, G. F.; Manipon, G.; Linick, J. P.; Fielding, E. J.; Lundgren, P.; Farr, T. G.; Webb, F.; Rosen, P. A.; Simons, M.

    2017-12-01

    The Advanced Rapid Imaging and Analysis (ARIA) project for Natural Hazards is focused on rapidly generating high-level geodetic imaging products and placing them in the hands of the solid earth science and local, national, and international natural hazard communities by providing science product generation, exploration, and delivery capabilities at an operational level. Space-based geodetic measurement techniques including Interferometric Synthetic Aperture Radar (InSAR), differential Global Positioning System, and SAR-based change detection have become critical additions to our toolset for understanding and mapping the damage and deformation caused by earthquakes, volcanic eruptions, floods, landslides, and groundwater extraction. Up until recently, processing of these data sets has been handcrafted for each study or event and has not generated products rapidly and reliably enough for response to natural disasters or for timely analysis of large data sets. The ARIA project, a joint venture co-sponsored by the California Institute of Technology and by NASA through the Jet Propulsion Laboratory, has been capturing the knowledge applied to these responses and building it into an automated infrastructure to generate imaging products in near real-time that can improve situational awareness for disaster response. In addition to supporting the growing science and hazard response communities, the ARIA project has developed the capabilities to provide automated imaging and analysis capabilities necessary to keep up with the influx of raw SAR data from geodetic imaging missions such as ESA's Sentinel-1A/B, now operating with repeat intervals as short as 6 days, and the upcoming NASA NISAR mission. We will present the progress and results we have made on automating the analysis of Sentinel-1A/B SAR data for hazard monitoring and response, with emphasis on recent developments and end user engagement in flood extent mapping and deformation time series for both volcano

  3. A Laboratory Experiment for Rapid Determination of the Stability of Vitamin C

    Science.gov (United States)

    Adem, Seid M.; Lueng, Sam H.; Elles, Lisa M. Sharpe; Shaver, Lee Alan

    2016-01-01

    Experiments in laboratory manuals intended for general, organic, and biological (GOB) chemistry laboratories include few opportunities for students to engage in instrumental methods of analysis. Many of these students seek careers in modern health-related fields where experience in spectroscopic techniques would be beneficial. A simple, rapid,…

  4. New layer-based imaging and rapid prototyping techniques for computer-aided design and manufacture of custom dental restoration.

    Science.gov (United States)

    Lee, M-Y; Chang, C-C; Ku, Y C

    2008-01-01

    Fixed dental restoration by conventional methods greatly relies on the skill and experience of the dental technician. The quality and accuracy of the final product depends mostly on the technician's subjective judgment. In addition, the traditional manual operation involves many complex procedures, and is a time-consuming and labour-intensive job. Most importantly, no quantitative design and manufacturing information is preserved for future retrieval. In this paper, a new device for scanning the dental profile and reconstructing 3D digital information of a dental model based on a layer-based imaging technique, called abrasive computer tomography (ACT) was designed in-house and proposed for the design of custom dental restoration. The fixed partial dental restoration was then produced by rapid prototyping (RP) and computer numerical control (CNC) machining methods based on the ACT scanned digital information. A force feedback sculptor (FreeForm system, Sensible Technologies, Inc., Cambridge MA, USA), which comprises 3D Touch technology, was applied to modify the morphology and design of the fixed dental restoration. In addition, a comparison of conventional manual operation and digital manufacture using both RP and CNC machining technologies for fixed dental restoration production is presented. Finally, a digital custom fixed restoration manufacturing protocol integrating proposed layer-based dental profile scanning, computer-aided design, 3D force feedback feature modification and advanced fixed restoration manufacturing techniques is illustrated. The proposed method provides solid evidence that computer-aided design and manufacturing technologies may become a new avenue for custom-made fixed restoration design, analysis, and production in the 21st century.

  5. Kinematics analysis technique fouettes 720° classic ballet.

    Directory of Open Access Journals (Sweden)

    Li Bo

    2011-07-01

    Full Text Available Athletics practice proved that the more complex the item, the more difficult technique of the exercises. Fouettes at 720° one of the most difficult types of the fouettes. Its implementation is based on high technology during rotation of the performer. To perform this element not only requires good physical condition of the dancer, but also requires possession correct technique dancer. On the basis corresponding kinematic theory in this study, qualitative analysis and quantitative assessment of fouettes at 720 by the best Chinese dancers. For analysis, was taken the method of stereoscopic images and the theoretical analysis.

  6. A Comparative Study with RapidMiner and WEKA Tools over some Classification Techniques for SMS Spam

    Science.gov (United States)

    Foozy, Cik Feresa Mohd; Ahmad, Rabiah; Faizal Abdollah, M. A.; Chai Wen, Chuah

    2017-08-01

    SMS Spamming is a serious attack that can manipulate the use of the SMS by spreading the advertisement in bulk. By sending the unwanted SMS that contain advertisement can make the users feeling disturb and this against the privacy of the mobile users. To overcome these issues, many studies have proposed to detect SMS Spam by using data mining tools. This paper will do a comparative study using five machine learning techniques such as Naïve Bayes, K-NN (K-Nearest Neighbour Algorithm), Decision Tree, Random Forest and Decision Stumps to observe the accuracy result between RapidMiner and WEKA for dataset SMS Spam UCI Machine Learning repository.

  7. Skills and Vacancy Analysis with Data Mining Techniques

    Directory of Open Access Journals (Sweden)

    Izabela A. Wowczko

    2015-11-01

    Full Text Available Through recognizing the importance of a qualified workforce, skills research has become one of the focal points in economics, sociology, and education. Great effort is dedicated to analyzing labor demand and supply, and actions are taken at many levels to match one with the other. In this work we concentrate on skills needs, a dynamic variable dependent on many aspects such as geography, time, or the type of industry. Historically, skills in demand were easy to evaluate since transitions in that area were fairly slow, gradual, and easy to adjust to. In contrast, current changes are occurring rapidly and might take an unexpected turn. Therefore, we introduce a relatively simple yet effective method of monitoring skills needs straight from the source—as expressed by potential employers in their job advertisements. We employ open source tools such as RapidMiner and R as well as easily accessible online vacancy data. We demonstrate selected techniques, namely classification with k-NN and information extraction from a textual dataset, to determine effective ways of discovering knowledge from a given collection of vacancies.

  8. [Rapid karyotyping in the 2nd and 3rd trimester: results and experiences].

    Science.gov (United States)

    Claussen, U; Voigt, H J; Ulmer, R; Beinder, E

    1995-01-01

    Rapid karyotyping in the second and third trimester is an increasing field of collaboration between women's hospitals and human genetics. Techniques available for rapid karyotyping are: 1. Amniocentesis; to obtain amniotic fluid cells for culturing and subsequent chromosome harvesting using the pipette method or the "in situ" technique. The average time between preparation of the amniotic fluid and the verbal notification of the analysed karyotype is 4.65 days for the pipette method and 5.97 days for the "in situ" technique. The major advantages are that amniocentesis can be handled safely by many gynaecologist, and the amniotic fluid samples can be posted easily to cytogenetic units familiar with rapid karyotyping. The main disadvantage is that currently only a few laboratories are able to handle the pipette method or the "in situ" technique for rapid karyotyping. 2. Fetal blood sampling (cordocentesis); and subsequent chromosome analysis on cultivated fetal lymphocytes leading to results within 2 to 4 days. The main advantage of this procedure is the reliability of the results obtained. Fetal blood sampling, however, is restricted to specialists; this may involve scheduling delays. 3. Placental biopsy; with subsequent direct preparation and long term culturing. In comparison to both other techniques this procedure is faster if direct preparation is used. Results can be obtained even on the same day. The main disadvantage, however, is the problem with the reliability of the direct preparation results. They must be confirmed by time-consuming long-term culturing. Data are presented on the likelihood of abnormal ultrasound findings being caused by chromosomal aberrations.(ABSTRACT TRUNCATED AT 250 WORDS)

  9. Toward rapid analysis, forecast and discovery of bioactive compounds from herbs by jointly using thin layer chromatography and ratiometric surface-enhanced Raman spectroscopy technique.

    Science.gov (United States)

    Gu, Xiaoling; Jin, Yang; Dong, Fang; Cai, Yueqing; You, Zhengyi; You, Junhui; Zhang, Liying; Du, Shuhu

    2018-05-10

    Conventional isolation and identification of active compounds from herbs have been extensively reported by using various chromatographic and spectroscopic techniques. However, how to quickly discover new bioactive ingredients from natural sources still remains a challenging task due to the interference of their similar structures or matrices. Here, we present a grand approach for rapid analysis, forecast and discovery of bioactive compounds from herbs based on a hyphenated strategy of thin layer chromatography and ratiometric surface-enhanced Raman spectroscopy. The performance of the hyphenated strategy is first evaluated by analyzing four protoberberine alkaloids, berberine (BER), coptisine (COP), palmatine (PAT) and jatrorrhizine (JAT), from a typical herb Coptidis Rhizoma as an example. It has been demonstrated that this coupling method can identify the four compounds by characteristic peaks at 728, 708, 736 and 732 cm -1 , and especially discriminate BER and COP (with similar migration distances) by ratiometric Raman intensity (I 708 /I 728 ). The corresponding limits of detection are 0.1, 0.05, 0.1 and 0.5 μM, respectively, which are about 1-2 orders of magnitude lower than those of direct observation method under 254 nm UV lamp. Based on these findings, the proposed method further guides forecast and discovery of unknown compounds from traditional Chinese herb Typhonii Rhizoma. Results infer that two trace alkaloids (BER and COP) from the n-butanol extract of Typhonii Rhizoma are found for the first time. Moreover, in vitro experiments manifest that BER can effectively decrease the viability of human glioma U87 cells by inducing cell cycle arrest in a concentration-dependent manner. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. Nuclear techniques for bulk and surface analysis of materials

    International Nuclear Information System (INIS)

    D'Agostino, M.D.; Kamykowski, E.A.; Kuehne, F.J.; Padawer, G.M.; Schneid, E.J.; Schulte, R.L.; Stauber, M.C.; Swanson, F.R.

    1978-01-01

    A review is presented summarizing several nondestructive bulk and surface analysis nuclear techniques developed in the Grumman Research Laboratories. Bulk analysis techniques include 14-MeV-neutron activation analysis and accelerator-based neutron radiography. The surface analysis techniques include resonant and non-resonant nuclear microprobes for the depth profile analysis of light elements (H, He, Li, Be, C, N, O and F) in the surface of materials. Emphasis is placed on the description and discussion of the unique nuclear microprobe analytical capacibilities of immediate importance to a number of current problems facing materials specialists. The resolution and contrast of neutron radiography was illustrated with an operating heat pipe system. The figure shows that the neutron radiograph has a resolution of better than 0.04 cm with sufficient contrast to indicate Freon 21 on the inner capillaries of the heat pipe and pooling of the liquid at the bottom. (T.G.)

  11. Event tree analysis using artificial intelligence techniques

    International Nuclear Information System (INIS)

    Dixon, B.W.; Hinton, M.F.

    1985-01-01

    Artificial Intelligence (AI) techniques used in Expert Systems and Object Oriented Programming are discussed as they apply to Event Tree Analysis. A SeQUence IMPortance calculator, SQUIMP, is presented to demonstrate the implementation of these techniques. Benefits of using AI methods include ease of programming, efficiency of execution, and flexibility of application. The importance of an appropriate user interface is stressed. 5 figs

  12. Rapid 3-D analysis of rockfalls

    Science.gov (United States)

    Stock, Greg M.; Guerin, A.; Avdievitch, Nikita N.; Collins, Brian D.; Jaboyedoff, Michel

    2018-01-01

    Recent fatal and damaging rockfalls in Yosemite National Park indicate the need for rapid response data collection methods to inform public safety and assist with management response. Here we show the use of multiple-platform remote sensing methods to rapidly capture pertinent data needed to inform management and the public following a several large rockfalls from El Capitan cliff in Yosemite Valley, California.

  13. The development of human behavior analysis techniques

    International Nuclear Information System (INIS)

    Lee, Jung Woon; Lee, Yong Hee; Park, Geun Ok; Cheon, Se Woo; Suh, Sang Moon; Oh, In Suk; Lee, Hyun Chul; Park, Jae Chang.

    1997-07-01

    In this project, which is to study on man-machine interaction in Korean nuclear power plants, we developed SACOM (Simulation Analyzer with a Cognitive Operator Model), a tool for the assessment of task performance in the control rooms using software simulation, and also develop human error analysis and application techniques. SACOM was developed to assess operator's physical workload, workload in information navigation at VDU workstations, and cognitive workload in procedural tasks. We developed trip analysis system including a procedure based on man-machine interaction analysis system including a procedure based on man-machine interaction analysis and a classification system. We analyzed a total of 277 trips occurred from 1978 to 1994 to produce trip summary information, and for 79 cases induced by human errors time-lined man-machine interactions. The INSTEC, a database system of our analysis results, was developed. The MARSTEC, a multimedia authoring and representation system for trip information, was also developed, and techniques for human error detection in human factors experiments were established. (author). 121 refs., 38 tabs., 52 figs

  14. The development of human behavior analysis techniques

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jung Woon; Lee, Yong Hee; Park, Geun Ok; Cheon, Se Woo; Suh, Sang Moon; Oh, In Suk; Lee, Hyun Chul; Park, Jae Chang

    1997-07-01

    In this project, which is to study on man-machine interaction in Korean nuclear power plants, we developed SACOM (Simulation Analyzer with a Cognitive Operator Model), a tool for the assessment of task performance in the control rooms using software simulation, and also develop human error analysis and application techniques. SACOM was developed to assess operator`s physical workload, workload in information navigation at VDU workstations, and cognitive workload in procedural tasks. We developed trip analysis system including a procedure based on man-machine interaction analysis system including a procedure based on man-machine interaction analysis and a classification system. We analyzed a total of 277 trips occurred from 1978 to 1994 to produce trip summary information, and for 79 cases induced by human errors time-lined man-machine interactions. The INSTEC, a database system of our analysis results, was developed. The MARSTEC, a multimedia authoring and representation system for trip information, was also developed, and techniques for human error detection in human factors experiments were established. (author). 121 refs., 38 tabs., 52 figs.

  15. Nuclear analytical techniques in medicine

    International Nuclear Information System (INIS)

    Cesareo, R.

    1988-01-01

    This book acquaints one with the fundamental principles and the instrumentation relevant to analytical technique based on atomic and nuclear physics, as well as present and future biomedical applications. Besides providing a theoretical description of the physical phenomena, a large part of the book is devoted to applications in the medical and biological field, particularly in hematology, forensic medicine and environmental science. This volume reviews methods such as the possibility of carrying out rapid multi-element analysis of trace elements on biomedical samples, in vitro and in vivo, by XRF-analysis; the ability of the PIXE-microprobe to analyze in detail and to map trace elements in fragments of biomedical samples or inside the cells; the potentiality of in vivo nuclear activation analysis for diagnostic purposes. Finally, techniques are described such as radiation scattering (elastic and inelastic scattering) and attenuation measurements which will undoubtedly see great development in the immediate future

  16. Nuclear analytical techniques in medicine

    Energy Technology Data Exchange (ETDEWEB)

    Cesareo, R.

    1988-01-01

    This book acquaints one with the fundamental principles and the instrumentation relevant to analytical technique based on atomic and nuclear physics, as well as present and future biomedical applications. Besides providing a theoretical description of the physical phenomena, a large part of the book is devoted to applications in the medical and biological field, particularly in hematology, forensic medicine and environmental science. This volume reviews methods such as the possibility of carrying out rapid multi-element analysis of trace elements on biomedical samples, in vitro and in vivo, by XRF-analysis; the ability of the PIXE-microprobe to analyze in detail and to map trace elements in fragments of biomedical samples or inside the cells; the potentiality of in vivo nuclear activation analysis for diagnostic purposes. Finally, techniques are described such as radiation scattering (elastic and inelastic scattering) and attenuation measurements which will undoubtedly see great development in the immediate future.

  17. Spectroscopic analysis technique for arc-welding process control

    Science.gov (United States)

    Mirapeix, Jesús; Cobo, Adolfo; Conde, Olga; Quintela, María Ángeles; López-Higuera, José-Miguel

    2005-09-01

    The spectroscopic analysis of the light emitted by thermal plasmas has found many applications, from chemical analysis to monitoring and control of industrial processes. Particularly, it has been demonstrated that the analysis of the thermal plasma generated during arc or laser welding can supply information about the process and, thus, about the quality of the weld. In some critical applications (e.g. the aerospace sector), an early, real-time detection of defects in the weld seam (oxidation, porosity, lack of penetration, ...) is highly desirable as it can reduce expensive non-destructive testing (NDT). Among others techniques, full spectroscopic analysis of the plasma emission is known to offer rich information about the process itself, but it is also very demanding in terms of real-time implementations. In this paper, we proposed a technique for the analysis of the plasma emission spectrum that is able to detect, in real-time, changes in the process parameters that could lead to the formation of defects in the weld seam. It is based on the estimation of the electronic temperature of the plasma through the analysis of the emission peaks from multiple atomic species. Unlike traditional techniques, which usually involve peak fitting to Voigt functions using the Levenberg-Marquardt recursive method, we employ the LPO (Linear Phase Operator) sub-pixel algorithm to accurately estimate the central wavelength of the peaks (allowing an automatic identification of each atomic species) and cubic-spline interpolation of the noisy data to obtain the intensity and width of the peaks. Experimental tests on TIG-welding using fiber-optic capture of light and a low-cost CCD-based spectrometer, show that some typical defects can be easily detected and identified with this technique, whose typical processing time for multiple peak analysis is less than 20msec. running in a conventional PC.

  18. A rapid, solid phase extraction (SPE technique for the extraction and gas chromatographic determination lindane pesticide residue in tissue and milk

    Directory of Open Access Journals (Sweden)

    Yuningsih

    2006-03-01

    Full Text Available Organochlorine pesticide contamination in feed can cause residue in animal product (tissue and milk, so its become a problem in food safety. Solid phase extraction (SPE has been carried out for determination organochlorine pesticide residues in food animal production. The technique was rapid, not costly and produce limited amount of hazardous-waste. Samples were homogenized with acetonitrile trough cartridge C18, eluted in fluorocyl column with 2% ether-petroleum or acetonitrile fortissue and milk samples respectively. The recoveries of tissue sample by addition lindane standard solution: 0.50 and 1.00 μg are 85.10 and 103.10% respectively, while that of milk with the addition of 0.50, 1.00 and 1.50 μg are 83.80, 88.69 and 91.24% respectively. Three replicates were carried out for every sample. According of validation criteria of FAO/IAEA the recovery for analysis of pesticide residues was 70-110%. Therefore, the method is applicable.

  19. Determining the Number of Factors in P-Technique Factor Analysis

    Science.gov (United States)

    Lo, Lawrence L.; Molenaar, Peter C. M.; Rovine, Michael

    2017-01-01

    Determining the number of factors is a critical first step in exploratory factor analysis. Although various criteria and methods for determining the number of factors have been evaluated in the usual between-subjects R-technique factor analysis, there is still question of how these methods perform in within-subjects P-technique factor analysis. A…

  20. 10th Australian conference on nuclear techniques of analysis. Proceedings

    International Nuclear Information System (INIS)

    1998-01-01

    These proceedings contains abstracts and extended abstracts of 80 lectures and posters presented at the 10th Australian conference on nuclear techniques of analysis hosted by the Australian National University in Canberra, Australia from 24-26 of November 1997. The conference was divided into sessions on the following topics : ion beam analysis and its applications; surface science; novel nuclear techniques of analysis, characterization of thin films, electronic and optoelectronic material formed by ion implantation, nanometre science and technology, plasma science and technology. A special session was dedicated to new nuclear techniques of analysis, future trends and developments. Separate abstracts were prepared for the individual presentation included in this volume

  1. 10th Australian conference on nuclear techniques of analysis. Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-06-01

    These proceedings contains abstracts and extended abstracts of 80 lectures and posters presented at the 10th Australian conference on nuclear techniques of analysis hosted by the Australian National University in Canberra, Australia from 24-26 of November 1997. The conference was divided into sessions on the following topics : ion beam analysis and its applications; surface science; novel nuclear techniques of analysis, characterization of thin films, electronic and optoelectronic material formed by ion implantation, nanometre science and technology, plasma science and technology. A special session was dedicated to new nuclear techniques of analysis, future trends and developments. Separate abstracts were prepared for the individual presentation included in this volume.

  2. Technique for determining cesium-137 in milk excluding ashing

    International Nuclear Information System (INIS)

    Antonova, V.A.; Prokof'ev, O.N.

    1984-01-01

    For the purpose of simplification of the method of milk sample preparation for the radiochemical analysis for 137 Cs in laboratory sanitary and higienic investigations rapid analysis technique excluding sample ashing is developed. The technique comprises sample mixing with silica gel during an hour, 137 Cs desorption from silica gel into the 1N solution of hydrochloric acid, radiochemical analysis of hydrochloric solution for determining 137 Cs. The comparison of the results obtained by the above method and that with ashing provides perfect agreement. For taking into account the incompleteness of 137 Cs adsorption by silica gel a correction factor is applied in calculation formulae

  3. Rapid Exploitation and Analysis of Documents

    Energy Technology Data Exchange (ETDEWEB)

    Buttler, D J; Andrzejewski, D; Stevens, K D; Anastasiu, D; Gao, B

    2011-11-28

    Analysts are overwhelmed with information. They have large archives of historical data, both structured and unstructured, and continuous streams of relevant messages and documents that they need to match to current tasks, digest, and incorporate into their analysis. The purpose of the READ project is to develop technologies to make it easier to catalog, classify, and locate relevant information. We approached this task from multiple angles. First, we tackle the issue of processing large quantities of information in reasonable time. Second, we provide mechanisms that allow users to customize their queries based on latent topics exposed from corpus statistics. Third, we assist users in organizing query results, adding localized expert structure over results. Forth, we use word sense disambiguation techniques to increase the precision of matching user generated keyword lists with terms and concepts in the corpus. Fifth, we enhance co-occurrence statistics with latent topic attribution, to aid entity relationship discovery. Finally we quantitatively analyze the quality of three popular latent modeling techniques to examine under which circumstances each is useful.

  4. The financial impact of the incorporation of IMRT and RapidArc™ techniques on shielding calculation of a linear accelerator

    International Nuclear Information System (INIS)

    Santos, Maira R.; Silveira, Thiago B.; Garcia, Paulo L.; Trindade, Cassia; Martins, Lais P.; Batista, Delano V.S.

    2013-01-01

    Given the new methodology introduced in the shielding calculation due to recent modulated techniques in radiotherapy treatment, it became necessary to evaluate the impact of changes in the accelerator routine using such techniques. Based on a group of 30 patients from the National Cancer Institute (INCA) the workload multiplier factors for intensity modulated radiotherapy (IMRT factor) and for RapidArc™ (RA factor) were established. Four different routines in a 6 MV generic accelerator were proposed to estimate the impact of these modified workloads in the building cost of the secondary barriers. The results indicate that if 50% of patients are treating with IMRT, the secondary barrier becomes 14,1% more expensive than the barrier calculated for conformal treatments exclusive. While RA, in the same proportion, leads to a barrier only 3,7% more expensive. Showing that RA can, while reducing treatment time, increase the proportion of patients treated with modulation technique, without increasing the cost of the barrier, when compared with IMRT. (author)

  5. Integrating Remote Sensing Data, Hybrid-Cloud Computing, and Event Notifications for Advanced Rapid Imaging & Analysis (Invited)

    Science.gov (United States)

    Hua, H.; Owen, S. E.; Yun, S.; Lundgren, P.; Fielding, E. J.; Agram, P.; Manipon, G.; Stough, T. M.; Simons, M.; Rosen, P. A.; Wilson, B. D.; Poland, M. P.; Cervelli, P. F.; Cruz, J.

    2013-12-01

    Space-based geodetic measurement techniques such as Interferometric Synthetic Aperture Radar (InSAR) and Continuous Global Positioning System (CGPS) are now important elements in our toolset for monitoring earthquake-generating faults, volcanic eruptions, hurricane damage, landslides, reservoir subsidence, and other natural and man-made hazards. Geodetic imaging's unique ability to capture surface deformation with high spatial and temporal resolution has revolutionized both earthquake science and volcanology. Continuous monitoring of surface deformation and surface change before, during, and after natural hazards improves decision-making from better forecasts, increased situational awareness, and more informed recovery. However, analyses of InSAR and GPS data sets are currently handcrafted following events and are not generated rapidly and reliably enough for use in operational response to natural disasters. Additionally, the sheer data volumes needed to handle a continuous stream of InSAR data sets also presents a bottleneck. It has been estimated that continuous processing of InSAR coverage of California alone over 3-years would reach PB-scale data volumes. Our Advanced Rapid Imaging and Analysis for Monitoring Hazards (ARIA-MH) science data system enables both science and decision-making communities to monitor areas of interest with derived geodetic data products via seamless data preparation, processing, discovery, and access. We will present our findings on the use of hybrid-cloud computing to improve the timely processing and delivery of geodetic data products, integrating event notifications from USGS to improve the timely processing for response, as well as providing browse results for quick looks with other tools for integrative analysis.

  6. Computer-controlled system for rapid soil analysis of 226Ra

    International Nuclear Information System (INIS)

    Doane, R.W.; Berven, B.A.; Blair, M.S.

    1984-01-01

    A computer-controlled multichannel analysis system has been developed by the Radiological Survey Activities Group at Oak Ridge National Laboratory (ORNL) for the Department of Energy (DOE) in support of the DOE's remedial action programs. The purpose of this system is to provide a rapid estimate of the 226 Ra concentration in soil samples using a 6 x 9-in. NaI(Tl) crystal containing a 3.25-in. deep by 3.5-in. diameter well. This gamma detection system is controlled by a mini-computer with a dual floppy disk storage medium. A two-chip interface was also designed at ORNL which handles all control signals generated from the computer keyboard. These computer-generated control signals are processed in machine language for rapid data transfer and BASIC language is used for data processing

  7. Mobile Image Ratiometry: A New Method for Instantaneous Analysis of Rapid Test Strips

    OpenAIRE

    Donald C. Cooper; Bryan Callahan; Phil Callahan; Lee Burnett

    2012-01-01

    Here we describe Mobile Image Ratiometry (MIR), a new method for the automated quantification of standardized rapid immunoassay strips using consumer-based mobile smartphone and tablet cameras. To demonstrate MIR we developed a standardized method using rapid immunotest strips directed against cocaine (COC) and its major metabolite, benzoylecgonine (BE). We performed image analysis of three brands of commercially available dye-conjugated anti-COC/BE antibody test strips in response to three d...

  8. Reverse engineering--rapid prototyping of the skull in forensic trauma analysis.

    Science.gov (United States)

    Kettner, Mattias; Schmidt, Peter; Potente, Stefan; Ramsthaler, Frank; Schrodt, Michael

    2011-07-01

    Rapid prototyping (RP) comprises a variety of automated manufacturing techniques such as selective laser sintering (SLS), stereolithography, and three-dimensional printing (3DP), which use virtual 3D data sets to fabricate solid forms in a layer-by-layer technique. Despite a growing demand for (virtual) reconstruction models in daily forensic casework, maceration of the skull is frequently assigned to ensure haptic evidence presentation in the courtroom. Owing to the progress in the field of forensic radiology, 3D data sets of relevant cases are usually available to the forensic expert. Here, we present a first application of RP in forensic medicine using computed tomography scans for the fabrication of an SLS skull model in a case of fatal hammer impacts to the head. The report is intended to show that this method fully respects the dignity of the deceased and is consistent with medical ethics but nevertheless provides an excellent 3D impression of anatomical structures and injuries. © 2011 American Academy of Forensic Sciences.

  9. A numerical technique for reactor subchannel analysis

    International Nuclear Information System (INIS)

    Fath, Hassan E.S.

    1983-01-01

    A numerical technique is developed for the solution of the transient boundary layer equations with a moving liquid-vapour interface boundary. The technique uses the finite difference method with the velocity components defined over an Eulerian mesh. A system of interface massless markers is defined where the markers move with the flow field according to a simple kinematic relation between the interface geometry and the fluid velocity. Different applications of nuclear engineering interest are reported with some available results. The present technique is capable of predicting the interface profile near the wall which is important in the reactor subchannel analysis

  10. A probabilistic analysis of rapid boron dilution scenarios

    International Nuclear Information System (INIS)

    Kohut, P.; Diamond, D.J.

    1993-01-01

    A probabilistic and deterministic analysis of a rapid boron dilution scenario related to reactor restart was performed. The event is initiated by a loss of off-site power during the startup dilution process. The automatic restart of the charging pump in such cases may lead to the accumulation of a diluted slug of water in the lower plenum. The restart of the reactor coolant pumps may send the diluted slug through the core, adding sufficient reactivity to overcome the shutdown margin and cause a power excursion. The concern is that the power excursion is sufficient in certain circumstances to cause fuel damage. The estimated core damage frequency based on the scoping analysis is 1.0--3.0E-05/yr for the plants analyzed. These are relatively significant values when compared to desirable goals. The analysis contained assumptions related to plant specific design characteristics which may lead to non-conservative estimates. The most important conservative assumptions were that mixing of the injected diluted water is insignificant and that fuel damage occurs when the slug passes through the core

  11. Artificial intelligence techniques used in respiratory sound analysis--a systematic review.

    Science.gov (United States)

    Palaniappan, Rajkumar; Sundaraj, Kenneth; Sundaraj, Sebastian

    2014-02-01

    Artificial intelligence (AI) has recently been established as an alternative method to many conventional methods. The implementation of AI techniques for respiratory sound analysis can assist medical professionals in the diagnosis of lung pathologies. This article highlights the importance of AI techniques in the implementation of computer-based respiratory sound analysis. Articles on computer-based respiratory sound analysis using AI techniques were identified by searches conducted on various electronic resources, such as the IEEE, Springer, Elsevier, PubMed, and ACM digital library databases. Brief descriptions of the types of respiratory sounds and their respective characteristics are provided. We then analyzed each of the previous studies to determine the specific respiratory sounds/pathology analyzed, the number of subjects, the signal processing method used, the AI techniques used, and the performance of the AI technique used in the analysis of respiratory sounds. A detailed description of each of these studies is provided. In conclusion, this article provides recommendations for further advancements in respiratory sound analysis.

  12. A methodological comparison of customer service analysis techniques

    Science.gov (United States)

    James Absher; Alan Graefe; Robert Burns

    2003-01-01

    Techniques used to analyze customer service data need to be studied. Two primary analysis protocols, importance-performance analysis (IP) and gap score analysis (GA), are compared in a side-by-side comparison using data from two major customer service research projects. A central concern is what, if any, conclusion might be different due solely to the analysis...

  13. Rapid prototyping model for percutaneous nephrolithotomy training.

    Science.gov (United States)

    Bruyère, Franck; Leroux, Cecile; Brunereau, Laurent; Lermusiaux, Patrick

    2008-01-01

    Rapid prototyping is a technique used for creating computer images in three dimensions more efficiently than classic techniques. Percutaneous nephrolithotomy (PCNL) is a popular method to remove kidney stones; however, broader use by the urologic community has been hampered by the morbidity associated with needle puncture to gain access to the renal calix (bleeding, pneumothorax, hydrothorax, inadvertent colon injury). A training model to improve technique and understanding of renal anatomy could improve complications related to renal puncture; however, no model currently exists for resident training. We created a training model using the rapid prototyping technique based on abdominal CT images of a patient scheduled to undergo PCNL. This allowed our staff and residents to train on the model before performing the operation. This model allowed anticipation of particular difficulties inherent to the patient's anatomy. After training, the procedure proceeded without complication, and the patient was discharged at postoperative day 1 without problems. We hypothesize that rapid prototyping could be useful for resident education, allowing the creation of numerous models for research and surgical training. In addition, we anticipate that experienced urologists could find this technique helpful in preparation for difficult PCNL operations.

  14. Removing the bottleneck in whole genome sequencing of Mycobacterium tuberculosis for rapid drug resistance analysis: a call to action

    Directory of Open Access Journals (Sweden)

    Ruth McNerney

    2017-03-01

    Full Text Available Whole genome sequencing (WGS can provide a comprehensive analysis of Mycobacterium tuberculosis mutations that cause resistance to anti-tuberculosis drugs. With the deployment of bench-top sequencers and rapid analytical software, WGS is poised to become a useful tool to guide treatment. However, direct sequencing from clinical specimens to provide a full drug resistance profile remains a serious challenge. This article reviews current practices for extracting M. tuberculosis DNA and possible solutions for sampling sputum. Techniques under consideration include enzymatic digestion, physical disruption, chemical degradation, detergent solubilization, solvent extraction, ligand-coated magnetic beads, silica columns, and oligonucleotide pull-down baits. Selective amplification of genomic bacterial DNA in sputum prior to WGS may provide a solution, and differential lysis to reduce the levels of contaminating human DNA is also being explored. To remove this bottleneck and accelerate access to WGS for patients with suspected drug-resistant tuberculosis, it is suggested that a coordinated and collaborative approach be taken to more rapidly optimize, compare, and validate methodologies for sequencing from patient samples.

  15. Automated thermal mapping techniques using chromatic image analysis

    Science.gov (United States)

    Buck, Gregory M.

    1989-01-01

    Thermal imaging techniques are introduced using a chromatic image analysis system and temperature sensitive coatings. These techniques are used for thermal mapping and surface heat transfer measurements on aerothermodynamic test models in hypersonic wind tunnels. Measurements are made on complex vehicle configurations in a timely manner and at minimal expense. The image analysis system uses separate wavelength filtered images to analyze surface spectral intensity data. The system was initially developed for quantitative surface temperature mapping using two-color thermographic phosphors but was found useful in interpreting phase change paint and liquid crystal data as well.

  16. Modular techniques for dynamic fault-tree analysis

    Science.gov (United States)

    Patterson-Hine, F. A.; Dugan, Joanne B.

    1992-01-01

    It is noted that current approaches used to assess the dependability of complex systems such as Space Station Freedom and the Air Traffic Control System are incapable of handling the size and complexity of these highly integrated designs. A novel technique for modeling such systems which is built upon current techniques in Markov theory and combinatorial analysis is described. It enables the development of a hierarchical representation of system behavior which is more flexible than either technique alone. A solution strategy which is based on an object-oriented approach to model representation and evaluation is discussed. The technique is virtually transparent to the user since the fault tree models can be built graphically and the objects defined automatically. The tree modularization procedure allows the two model types, Markov and combinatoric, to coexist and does not require that the entire fault tree be translated to a Markov chain for evaluation. This effectively reduces the size of the Markov chain required and enables solutions with less truncation, making analysis of longer mission times possible. Using the fault-tolerant parallel processor as an example, a model is built and solved for a specific mission scenario and the solution approach is illustrated in detail.

  17. Microcalorimeter Q-spectroscopy for rapid isotopic analysis of trace actinide samples

    Energy Technology Data Exchange (ETDEWEB)

    Croce, M.P., E-mail: mpcroce@lanl.gov [Los Alamos National Laboratory, Los Alamos, NM (United States); Bond, E.M.; Hoover, A.S.; Kunde, G.J.; Mocko, V.; Rabin, M.W.; Weisse-Bernstein, N.R.; Wolfsberg, L.E. [Los Alamos National Laboratory, Los Alamos, NM (United States); Bennett, D.A.; Hays-Wehle, J.; Schmidt, D.R.; Ullom, J.N. [National Institute of Standards and Technology, Boulder, CO (United States)

    2015-06-01

    We are developing superconducting transition-edge sensor (TES) microcalorimeters that are optimized for rapid isotopic analysis of trace actinide samples by Q-spectroscopy. By designing mechanically robust TESs and simplified detector assembly methods, we have developed a detector for Q-spectroscopy of actinides that can be assembled in minutes. We have characterized the effects of each simplification and present the results. Finally, we show results of isotopic analysis of plutonium samples with Q-spectroscopy detectors and compare the results to mass spectrometry.

  18. Microcalorimeter Q-spectroscopy for rapid isotopic analysis of trace actinide samples

    International Nuclear Information System (INIS)

    Croce, M.P.; Bond, E.M.; Hoover, A.S.; Kunde, G.J.; Mocko, V.; Rabin, M.W.; Weisse-Bernstein, N.R.; Wolfsberg, L.E.; Bennett, D.A.; Hays-Wehle, J.; Schmidt, D.R.; Ullom, J.N.

    2015-01-01

    We are developing superconducting transition-edge sensor (TES) microcalorimeters that are optimized for rapid isotopic analysis of trace actinide samples by Q-spectroscopy. By designing mechanically robust TESs and simplified detector assembly methods, we have developed a detector for Q-spectroscopy of actinides that can be assembled in minutes. We have characterized the effects of each simplification and present the results. Finally, we show results of isotopic analysis of plutonium samples with Q-spectroscopy detectors and compare the results to mass spectrometry

  19. A rapid technique for analysis of formalin-fixed, paraffin-embedded tissues by fluorescent in situ hybridization with alpha-satellite probes

    Directory of Open Access Journals (Sweden)

    Nilce Barril

    1998-12-01

    Full Text Available We describe a rapid procedure for preparing archival tissues for interphase FISH analysis. The present protocol differs from others previously described because it allows the obtention of nuclei in satisfactory number and quality without using special equipments, adhesive-treated slides or solutions for chromatin decondensation. The method is of low cost and useful for retrospective analyses of formalin-fixed, paraffin-embedded samples.Descrevemos aqui um procedimento rápido para obtenção de núcleos interfásicos a partir de amostras arquivadas que podem ser utilizados para análise citogenética através da técnica de FISH. Este procedimento difere de outros previamente descritos porque permite a obtenção de núcleos em número e qualidade satisfatórios sem a utilização de equipamentos ou lâminas especiais e soluções para descondensação da cromatina. O método é de baixo custo e possibilita estudos retrospectivos de tecidos fixados em formol e emblocados em parafina.

  20. Key-space analysis of double random phase encryption technique

    Science.gov (United States)

    Monaghan, David S.; Gopinathan, Unnikrishnan; Naughton, Thomas J.; Sheridan, John T.

    2007-09-01

    We perform a numerical analysis on the double random phase encryption/decryption technique. The key-space of an encryption technique is the set of possible keys that can be used to encode data using that technique. In the case of a strong encryption scheme, many keys must be tried in any brute-force attack on that technique. Traditionally, designers of optical image encryption systems demonstrate only how a small number of arbitrary keys cannot decrypt a chosen encrypted image in their system. However, this type of demonstration does not discuss the properties of the key-space nor refute the feasibility of an efficient brute-force attack. To clarify these issues we present a key-space analysis of the technique. For a range of problem instances we plot the distribution of decryption errors in the key-space indicating the lack of feasibility of a simple brute-force attack.

  1. TECHNIQUE OF THE STATISTICAL ANALYSIS OF INVESTMENT APPEAL OF THE REGION

    Directory of Open Access Journals (Sweden)

    А. А. Vershinina

    2014-01-01

    Full Text Available The technique of the statistical analysis of investment appeal of the region is given in scientific article for direct foreign investments. Definition of a technique of the statistical analysis is given, analysis stages reveal, the mathematico-statistical tools are considered.

  2. Investigation of modified thin SnO2 layers treated by rapid thermal annealing by means of hollow cathode spectroscopy and AFM technique

    International Nuclear Information System (INIS)

    Djulgerova, R; Popova, L; Beshkov, G; Petrovic, Z Lju; Rakocevic, Z; Mihailov, V; Gencheva, V; Dohnalik, T

    2006-01-01

    By means of hollow cathode spectroscopy and atomic force microscopy the surface morphology and composition of SnO 2 thin film, modified with hexamethyldisilazane after rapid thermal annealing treatment (800-1200 deg. C), are investigated. Formation of crystalline structure is suggested at lower temperatures. Depolimerization, destruction and dehydration are developed at temperatures of 1200 deg. C. It is shown that the rapid thermal annealing treatment could modify both the surface morphology and the composition of the layer, thus changing the adsorption ability of the sensing layer. The results confirm the ability of hollow cathode emission spectroscopy for depth profiling of new materials especially combined with standard techniques

  3. Development of fault diagnostic technique using reactor noise analysis

    International Nuclear Information System (INIS)

    Park, Jin Ho; Kim, J. S.; Oh, I. S.; Ryu, J. S.; Joo, Y. S.; Choi, S.; Yoon, D. B.

    1999-04-01

    The ultimate goal of this project is to establish the analysis technique to diagnose the integrity of reactor internals using reactor noise. The reactor noise analyses techniques for the PWR and CANDU NPP(Nuclear Power Plants) were established by which the dynamic characteristics of reactor internals and SPND instrumentations could be identified, and the noise database corresponding to each plant(both Korean and foreign one) was constructed and compared. Also the change of dynamic characteristics of the Ulchin 1 and 2 reactor internals were simulated under presumed fault conditions. Additionally portable reactor noise analysis system was developed so that real time noise analysis could directly be able to be performed at plant site. The reactor noise analyses techniques developed and the database obtained from the fault simulation, can be used to establish a knowledge based expert system to diagnose the NPP's abnormal conditions. And the portable reactor noise analysis system may be utilized as a substitute for plant IVMS(Internal Vibration Monitoring System). (author)

  4. Development of fault diagnostic technique using reactor noise analysis

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jin Ho; Kim, J. S.; Oh, I. S.; Ryu, J. S.; Joo, Y. S.; Choi, S.; Yoon, D. B

    1999-04-01

    The ultimate goal of this project is to establish the analysis technique to diagnose the integrity of reactor internals using reactor noise. The reactor noise analyses techniques for the PWR and CANDU NPP(Nuclear Power Plants) were established by which the dynamic characteristics of reactor internals and SPND instrumentations could be identified, and the noise database corresponding to each plant(both Korean and foreign one) was constructed and compared. Also the change of dynamic characteristics of the Ulchin 1 and 2 reactor internals were simulated under presumed fault conditions. Additionally portable reactor noise analysis system was developed so that real time noise analysis could directly be able to be performed at plant site. The reactor noise analyses techniques developed and the database obtained from the fault simulation, can be used to establish a knowledge based expert system to diagnose the NPP's abnormal conditions. And the portable reactor noise analysis system may be utilized as a substitute for plant IVMS(Internal Vibration Monitoring System). (author)

  5. Rapid chemical separations

    CERN Document Server

    Trautmann, N

    1976-01-01

    A survey is given on the progress of fast chemical separation procedures during the last few years. Fast, discontinuous separation techniques are illustrated by a procedure for niobium. The use of such techniques for the chemical characterization of the heaviest known elements is described. Other rapid separation methods from aqueous solutions are summarized. The application of the high speed liquid chromatography to the separation of chemically similar elements is outlined. The use of the gas jet recoil transport method for nuclear reaction products and its combination with a continuous solvent extraction technique and with a thermochromatographic separation is presented. Different separation methods in the gas phase are briefly discussed and the attachment of a thermochromatographic technique to an on-line mass separator is shown. (45 refs).

  6. Multivariate Analysis Techniques for Optimal Vision System Design

    DEFF Research Database (Denmark)

    Sharifzadeh, Sara

    The present thesis considers optimization of the spectral vision systems used for quality inspection of food items. The relationship between food quality, vision based techniques and spectral signature are described. The vision instruments for food analysis as well as datasets of the food items...... used in this thesis are described. The methodological strategies are outlined including sparse regression and pre-processing based on feature selection and extraction methods, supervised versus unsupervised analysis and linear versus non-linear approaches. One supervised feature selection algorithm...... (SSPCA) and DCT based characterization of the spectral diffused reflectance images for wavelength selection and discrimination. These methods together with some other state-of-the-art statistical and mathematical analysis techniques are applied on datasets of different food items; meat, diaries, fruits...

  7. Chromatographic Techniques for Rare Earth Elements Analysis

    Science.gov (United States)

    Chen, Beibei; He, Man; Zhang, Huashan; Jiang, Zucheng; Hu, Bin

    2017-04-01

    The present capability of rare earth element (REE) analysis has been achieved by the development of two instrumental techniques. The efficiency of spectroscopic methods was extraordinarily improved for the detection and determination of REE traces in various materials. On the other hand, the determination of REEs very often depends on the preconcentration and separation of REEs, and chromatographic techniques are very powerful tools for the separation of REEs. By coupling with sensitive detectors, many ambitious analytical tasks can be fulfilled. Liquid chromatography is the most widely used technique. Different combinations of stationary phases and mobile phases could be used in ion exchange chromatography, ion chromatography, ion-pair reverse-phase chromatography and some other techniques. The application of gas chromatography is limited because only volatile compounds of REEs can be separated. Thin-layer and paper chromatography are techniques that cannot be directly coupled with suitable detectors, which limit their applications. For special demands, separations can be performed by capillary electrophoresis, which has very high separation efficiency.

  8. Rapid-swept CW cavity ring-down laser spectroscopy for carbon isotope analysis

    International Nuclear Information System (INIS)

    Tomita, Hideki; Watanabe, Kenichi; Takiguchi, Yu; Kawarabayashi, Jun; Iguchi, Tetsuo

    2006-01-01

    With the aim of developing a portable system for an in field isotope analysis, we investigate an isotope analysis based on rapid-swept CW cavity ring-down laser spectroscopy, in which the concentration of a chemical species is derived from its photo absorbance. Such a system can identify the isotopomer and still be constructed as a quite compact system. We have made some basic experimental measurements of the overtone absorption lines of carbon dioxide ( 12 C 16 O 2 , 13 C 16 O 2 ) by rapid-swept cavity ring-down spectroscopy with a CW infrared diode laser at 6,200 cm -1 (1.6 μm). The isotopic ratio has been obtained as (1.07±0.13)x10 -2 , in good agreement with the natural abundance within experimental uncertainty. The detection sensitivity in absorbance has been estimated to be 3x10 -8 cm -1 . (author)

  9. Dependence of mitochondrial and cytosolic adenine nucleotides on oxygen partial pressure in isolated hepatocytes. Application of a new rapid high pressure filtration technique for fractionation.

    OpenAIRE

    Hummerich, H; de Groot, H; Noll, T; Soboll, S

    1988-01-01

    By using a new rapid high pressure filtration technique, mitochondrial and cytosolic ATP and ADP contents were determined in isolated hepatocytes at different oxygen partial pressures. At 670 mmHg, subcellular adenine nucleotide contents and ATP/ADP ratios were comparable with values obtained with the digitonin fractionation technique. However at lower oxygen partial pressure ADP appears to be rephosphorylated during digitonin fractionation whereas with high pressure filtration fractionation ...

  10. Application of a rapid screening method to detect irradiated meat in Brazil

    International Nuclear Information System (INIS)

    Villavicencio, A.L.C.H.; Delincee, H.

    1998-01-01

    Complete text of publication follows. Based on the enormous potential for food irradiation in Brazil, and to ensure free consumer choice, there is a need to find a convenient and rapid method for detection of irradiated food. Since treatment with ionizing radiation causes DNA fragmentation, the analysis of DNA damage might be promising. In fact, DNA fragmentation measured in single cells by agarose gel electrophoresis - DNA Comet Assay - has shown to offer great potential as a rapid tool to detect whether a wide variety of foodstuffs has been radiation processed. However, more work is needed to exploit the full potential of this promising technique. In this paper, the DNA Comet Assay was used to identify exotic meat (boar, jacare and capybara), irradiated with 60 Co gamma-rays. The applied radiation doses were 0, 1.5, 3.0 and 4.5 kGy. Analysis of the DNA migration enable a rapid identification of the radiation treatment

  11. Neutron activation analysis: an emerging technique for conservation/preservation

    International Nuclear Information System (INIS)

    Sayre, E.V.

    1976-01-01

    The diverse applications of neutron activation in analysis, preservation, and documentation of art works and artifacts are described with illustrations for each application. The uses of this technique to solve problems of attribution and authentication, to reveal the inner structure and composition of art objects, and, in some instances to recreate details of the objects are described. A brief discussion of the theory and techniques of neutron activation analysis is also included

  12. Diffraction analysis of customized illumination technique

    Science.gov (United States)

    Lim, Chang-Moon; Kim, Seo-Min; Eom, Tae-Seung; Moon, Seung Chan; Shin, Ki S.

    2004-05-01

    Various enhancement techniques such as alternating PSM, chrome-less phase lithography, double exposure, etc. have been considered as driving forces to lead the production k1 factor towards below 0.35. Among them, a layer specific optimization of illumination mode, so-called customized illumination technique receives deep attentions from lithographers recently. A new approach for illumination customization based on diffraction spectrum analysis is suggested in this paper. Illumination pupil is divided into various diffraction domains by comparing the similarity of the confined diffraction spectrum. Singular imaging property of individual diffraction domain makes it easier to build and understand the customized illumination shape. By comparing the goodness of image in each domain, it was possible to achieve the customized shape of illumination. With the help from this technique, it was found that the layout change would not gives the change in the shape of customized illumination mode.

  13. Decision Analysis Technique

    Directory of Open Access Journals (Sweden)

    Hammad Dabo Baba

    2014-01-01

    Full Text Available One of the most significant step in building structure maintenance decision is the physical inspection of the facility to be maintained. The physical inspection involved cursory assessment of the structure and ratings of the identified defects based on expert evaluation. The objective of this paper is to describe present a novel approach to prioritizing the criticality of physical defects in a residential building system using multi criteria decision analysis approach. A residential building constructed in 1985 was considered in this study. Four criteria which includes; Physical Condition of the building system (PC, Effect on Asset (EA, effect on Occupants (EO and Maintenance Cost (MC are considered in the inspection. The building was divided in to nine systems regarded as alternatives. Expert's choice software was used in comparing the importance of the criteria against the main objective, whereas structured Proforma was used in quantifying the defects observed on all building systems against each criteria. The defects severity score of each building system was identified and later multiplied by the weight of the criteria and final hierarchy was derived. The final ranking indicates that, electrical system was considered the most critical system with a risk value of 0.134 while ceiling system scored the lowest risk value of 0.066. The technique is often used in prioritizing mechanical equipment for maintenance planning. However, result of this study indicates that the technique could be used in prioritizing building systems for maintenance planning

  14. Rapid world modeling

    International Nuclear Information System (INIS)

    Little, Charles; Jensen, Ken

    2002-01-01

    Sandia National Laboratories has designed and developed systems capable of large-scale, three-dimensional mapping of unstructured environments in near real time. This mapping technique is called rapid world modeling and has proven invaluable when used by prototype systems consisting of sensory detection devices mounted on mobile platforms. These systems can be deployed into previously unmapped environments and transmit real-time 3-D visual images to operators located remotely. This paper covers a brief history of the rapid world modeling system, its implementation on mobile platforms, and the current state of the technology. Applications to the nuclear power industry are discussed. (author)

  15. Rapid MRI using a modified Dixon technique: a non-invasive and effective method for detection and monitoring of fatty metamorphosis of the liver

    Energy Technology Data Exchange (ETDEWEB)

    Fishbein, M.H. [Pediatric Gastroenterology, Dept. of Pediatrics, Springfield, IL (United States); Stevens, W.R. [St. John' s Hospital, Department of Radiology, Springfield, IL (United States)

    2001-11-01

    Fatty liver and non-alcoholic steatohepatitis are frequently associated with obesity. Weight loss is the mainstay of therapy for these conditions. In this case report, we used a modification of the Dixon method to demonstrate normalization of hepatic fat content in an obese individual with fatty liver following weight reduction. This technique involves fast gradient echo instead of spin echo, which has been utilized previously, as the former provides an accurate and more rapid means of assessing hepatic fat content. This technique is recommended for the assessment of hepatic steatosis in at-risk subjects. (orig.)

  16. Rapid MRI using a modified Dixon technique: a non-invasive and effective method for detection and monitoring of fatty metamorphosis of the liver

    International Nuclear Information System (INIS)

    Fishbein, M.H.; Stevens, W.R.

    2001-01-01

    Fatty liver and non-alcoholic steatohepatitis are frequently associated with obesity. Weight loss is the mainstay of therapy for these conditions. In this case report, we used a modification of the Dixon method to demonstrate normalization of hepatic fat content in an obese individual with fatty liver following weight reduction. This technique involves fast gradient echo instead of spin echo, which has been utilized previously, as the former provides an accurate and more rapid means of assessing hepatic fat content. This technique is recommended for the assessment of hepatic steatosis in at-risk subjects. (orig.)

  17. Study on rapid valid acidity evaluation of apple by fiber optic diffuse reflectance technique

    Science.gov (United States)

    Liu, Yande; Ying, Yibin; Fu, Xiaping; Jiang, Xuesong

    2004-03-01

    Some issues related to nondestructive evaluation of valid acidity in intact apples by means of Fourier transform near infrared (FTNIR) (800-2631nm) method were addressed. A relationship was established between the diffuse reflectance spectra recorded with a bifurcated optic fiber and the valid acidity. The data were analyzed by multivariate calibration analysis such as partial least squares (PLS) analysis and principal component regression (PCR) technique. A total of 120 Fuji apples were tested and 80 of them were used to form a calibration data set. The influence of data preprocessing and different spectra treatments were also investigated. Models based on smoothing spectra were slightly worse than models based on derivative spectra and the best result was obtained when the segment length was 5 and the gap size was 10. Depending on data preprocessing and multivariate calibration technique, the best prediction model had a correlation efficient (0.871), a low RMSEP (0.0677), a low RMSEC (0.056) and a small difference between RMSEP and RMSEC by PLS analysis. The results point out the feasibility of FTNIR spectral analysis to predict the fruit valid acidity non-destructively. The ratio of data standard deviation to the root mean square error of prediction (SDR) is better to be less than 3 in calibration models, however, the results cannot meet the demand of actual application. Therefore, further study is required for better calibration and prediction.

  18. Automated rapid particle investigation using scanning electron microscopy

    Science.gov (United States)

    Wilkins, Jerod Laurence

    The chemical composition of fly ash particles has been known to vary significantly depending on a number of factors. Current bulk methods of investigation including X-Ray Fluorescence and X-Ray Diffraction are thought to be inadequate in determining the performance of fly ash in concrete. It is the goal of this research to develop a method of Automated Rapid Particle Investigation that will not look at fly ash as a bulk material but as individual particles. By examining each particle individually scientists and engineers will have the ability to study the variation in chemical composition by comparing the chemistry present in each particle. The method of investigation developed by this research provides a practical technique that will allow the automated chemical analysis of hundreds, or even thousands, of fly ash particles in a matter of minutes upon completion of sample preparation and automated scanning electron microscope (ASEM) scanning. This research does not examine the significance of the chemical compounds discovered; rather, only the investigation methodology is discussed. Further research will be done to examine the importance of the chemistry discovered with this automated rapid particle investigation technique.

  19. 48 CFR 15.404-1 - Proposal analysis techniques.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Proposal analysis techniques. 15.404-1 Section 15.404-1 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION... assistance of other experts to ensure that an appropriate analysis is performed. (6) Recommendations or...

  20. We really need to talk: adapting FDA processes to rapid change.

    Science.gov (United States)

    Lykken, Sara

    2013-01-01

    The rapidly evolving realm of modern commerce strains traditional regulatory paradigms. This paper traces the historical evolution of FDA crisis-response regulation and provides examples of ways in which the definitions and procedures resulting from that past continue to be challenged by new products as market entrants, some in good faith and others not, take actions that create disconnects between actual product and marketing controls and those that consumers might expect. The paper then explores some of the techniques used by other federal agencies that have faced similar challenges in environments characterized by rapid innovation, and draws from this analysis suggestions for improvement of the FDA's warning letter system.

  1. Rapid surface enhanced Raman scattering detection method for chloramphenicol residues

    Science.gov (United States)

    Ji, Wei; Yao, Weirong

    2015-06-01

    Chloramphenicol (CAP) is a widely used amide alcohol antibiotics, which has been banned from using in food producing animals in many countries. In this study, surface enhanced Raman scattering (SERS) coupled with gold colloidal nanoparticles was used for the rapid analysis of CAP. Density functional theory (DFT) calculations were conducted with Gaussian 03 at the B3LYP level using the 3-21G(d) and 6-31G(d) basis sets to analyze the assignment of vibrations. Affirmatively, the theoretical Raman spectrum of CAP was in complete agreement with the experimental spectrum. They both exhibited three strong peaks characteristic of CAP at 1104 cm-1, 1344 cm-1, 1596 cm-1, which were used for rapid qualitative analysis of CAP residues in food samples. The use of SERS as a method for the measurements of CAP was explored by comparing use of different solvents, gold colloidal nanoparticles concentration and absorption time. The method of the detection limit was determined as 0.1 μg/mL using optimum conditions. The Raman peak at 1344 cm-1 was used as the index for quantitative analysis of CAP in food samples, with a linear correlation of R2 = 0.9802. Quantitative analysis of CAP residues in foods revealed that the SERS technique with gold colloidal nanoparticles was sensitive and of a good stability and linear correlation, and suited for rapid analysis of CAP residue in a variety of food samples.

  2. Automated rapid chemistry in heavy element research

    International Nuclear Information System (INIS)

    Schaedel, M.

    1994-01-01

    With the increasingly short half-lives of the heavy element isotopes in the transition region from the heaviest actinides to the transactinide elements the demand for automated rapid chemistry techniques is also increasing. Separation times of significantly less than one minute, high chemical yields, high repetition rates, and an adequate detection system are prerequisites for many successful experiments in this field. The development of techniques for separations in the gas phase and in the aqueous phase for applications of chemical or nuclear studies of the heaviest elements are briefly outlined. Typical examples of results obtained with automated techniques are presented for studies up to element 105, especially those obtained with the Automated Rapid Chemistry Apparatus, ARCA. The prospects to investigate the properties of even heavier elements with chemical techniques are discussed

  3. Applications Of Binary Image Analysis Techniques

    Science.gov (United States)

    Tropf, H.; Enderle, E.; Kammerer, H. P.

    1983-10-01

    After discussing the conditions where binary image analysis techniques can be used, three new applications of the fast binary image analysis system S.A.M. (Sensorsystem for Automation and Measurement) are reported: (1) The human view direction is measured at TV frame rate while the subject's head is free movable. (2) Industrial parts hanging on a moving conveyor are classified prior to spray painting by robot. (3) In automotive wheel assembly, the eccentricity of the wheel is minimized by turning the tyre relative to the rim in order to balance the eccentricity of the components.

  4. AN ANALYSIS OF THE RAPID GROWTH FACTORS PRESENTED IN THE LITERATURE OF THE FIELD

    Directory of Open Access Journals (Sweden)

    ALB MARIA

    2015-03-01

    Full Text Available This paper presents the main rapid growth factors, as encountered in literature and discusses the importance and contribution of these factors in achieving the rapid growth, respectively if this growth phenomenon may be achieved in the absence of the aforesaid factors. The paper examines the factors and subfactors considered or found by scholars to have an effect on or be in connection with the rapid growth. A comparative analysis was performed on several studies concerning the rapid growth companies. Among the main factors influencing the rapid growth are those related to the human resources management, the entrepreneur characteritics and the characteristics of the business. The paper also discusses several issues related to the will of the manager or the entrepreneur, repectively the need to understand the role of the factors that intervene when the growth is not wanted and still obtained or when the growth is targeted but not achieved. The conclusion is in agreement with other scholars’ findings reported in the literature. Certain factors correlated with the appropriate actions may lead to the rapid growth. The paper represents a starting point for the study of those management related aspects enabling companies to grow rapidly in the Romanian business environment.

  5. Rapid detection of Escherichia coli and enterococci in recreational water using an immunomagnetic separation/adenosine triphosphate technique

    Science.gov (United States)

    Bushon, R.N.; Brady, A.M.; Likirdopulos, C.A.; Cireddu, J.V.

    2009-01-01

    Aims: The aim of this study was to examine a rapid method for detecting Escherichia coli and enterococci in recreational water. Methods and Results: Water samples were assayed for E. coli and enterococci by traditional and immunomagnetic separation/adenosine triphosphate (IMS/ATP) methods. Three sample treatments were evaluated for the IMS/ATP method: double filtration, single filtration, and direct analysis. Pearson's correlation analysis showed strong, significant, linear relations between IMS/ATP and traditional methods for all sample treatments; strongest linear correlations were with the direct analysis (r = 0.62 and 0.77 for E. coli and enterococci, respectively). Additionally, simple linear regression was used to estimate bacteria concentrations as a function of IMS/ATP results. The correct classification of water-quality criteria was 67% for E. coli and 80% for enterococci. Conclusions: The IMS/ATP method is a viable alternative to traditional methods for faecal-indicator bacteria. Significance and Impact of the Study: The IMS/ATP method addresses critical public health needs for the rapid detection of faecal-indicator contamination and has potential for satisfying US legislative mandates requiring methods to detect bathing water contamination in 2 h or less. Moreover, IMS/ATP equipment is considerably less costly and more portable than that for molecular methods, making the method suitable for field applications. ?? 2009 The Authors.

  6. Exploring data with RapidMiner

    CERN Document Server

    Chisholm, Andrew

    2013-01-01

    A step-by-step tutorial style using examples so that users of different levels will benefit from the facilities offered by RapidMiner.If you are a computer scientist or an engineer who has real data from which you want to extract value, this book is ideal for you. You will need to have at least a basic awareness of data mining techniques and some exposure to RapidMiner.

  7. Use of refractometry and colorimetry as field methods to rapidly assess antimalarial drug quality.

    Science.gov (United States)

    Green, Michael D; Nettey, Henry; Villalva Rojas, Ofelia; Pamanivong, Chansapha; Khounsaknalath, Lamphet; Grande Ortiz, Miguel; Newton, Paul N; Fernández, Facundo M; Vongsack, Latsamy; Manolin, Ot

    2007-01-04

    The proliferation of counterfeit and poor-quality drugs is a major public health problem; especially in developing countries lacking adequate resources to effectively monitor their prevalence. Simple and affordable field methods provide a practical means of rapidly monitoring drug quality in circumstances where more advanced techniques are not available. Therefore, we have evaluated refractometry, colorimetry and a technique combining both processes as simple and accurate field assays to rapidly test the quality of the commonly available antimalarial drugs; artesunate, chloroquine, quinine, and sulfadoxine. Method bias, sensitivity, specificity and accuracy relative to high-performance liquid chromatographic (HPLC) analysis of drugs collected in the Lao PDR were assessed for each technique. The HPLC method for each drug was evaluated in terms of assay variability and accuracy. The accuracy of the combined method ranged from 0.96 to 1.00 for artesunate tablets, chloroquine injectables, quinine capsules, and sulfadoxine tablets while the accuracy was 0.78 for enterically coated chloroquine tablets. These techniques provide a generally accurate, yet simple and affordable means to assess drug quality in resource-poor settings.

  8. Sensitivity analysis of hybrid thermoelastic techniques

    Science.gov (United States)

    W.A. Samad; J.M. Considine

    2017-01-01

    Stress functions have been used as a complementary tool to support experimental techniques, such as thermoelastic stress analysis (TSA) and digital image correlation (DIC), in an effort to evaluate the complete and separate full-field stresses of loaded structures. The need for such coupling between experimental data and stress functions is due to the fact that...

  9. Rapid mass spectrometric analysis of 15N-Leu incorporation fidelity during preparation of specifically labeled NMR samples

    DEFF Research Database (Denmark)

    Truhlar, Stephanie M E; Cervantes, Carla F; Torpey, Justin W

    2008-01-01

    . MALDI TOF-TOF MS/MS data provide additional information that shows where the "extra" (15)N labels are incorporated, which can be useful in confirming ambiguous assignments. The described procedure provides a rapid technique to monitor the fidelity of selective labeling that does not require a lot...

  10. Rapid Separation of Bacteria from Blood—Review and Outlook

    Science.gov (United States)

    Alizadeh, Mahsa; Husseini, Ghaleb A.; McClellan, Daniel S.; Buchanan, Clara M.; Bledsoe, Colin G.; Robison, Richard A.; Blanco, Rae; Roeder, Beverly L.; Melville, Madison; Hunter, Alex K.

    2017-01-01

    The high morbidity and mortality rate of bloodstream infections involving antibiotic-resistant bacteria necessitate a rapid identification of the infectious organism and its resistance profile. Traditional methods based on culturing the blood typically require at least 24 h, and genetic amplification by PCR in the presence of blood components has been problematic. The rapid separation of bacteria from blood would facilitate their genetic identification by PCR or other methods so that the proper antibiotic regimen can quickly be selected for the septic patient. Microfluidic systems that separate bacteria from whole blood have been developed, but these are designed to process only microliter quantities of whole blood or only highly diluted blood. However, symptoms of clinical blood infections can be manifest with bacterial burdens perhaps as low as 10 CFU/mL, and thus milliliter quantities of blood must be processed to collect enough bacteria for reliable genetic analysis. This review considers the advantages and shortcomings of various methods to separate bacteria from blood, with emphasis on techniques that can be done in less than 10 min on milliliter-quantities of whole blood. These techniques include filtration, screening, centrifugation, sedimentation, hydrodynamic focusing, chemical capture on surfaces or beads, field-flow fractionation, and dielectrophoresis. Techniques with the most promise include screening, sedimentation, and magnetic bead capture, as they allow large quantities of blood to be processed quickly. Some microfluidic techniques can be scaled up. PMID:27160415

  11. Computational System For Rapid CFD Analysis In Engineering

    Science.gov (United States)

    Barson, Steven L.; Ascoli, Edward P.; Decroix, Michelle E.; Sindir, Munir M.

    1995-01-01

    Computational system comprising modular hardware and software sub-systems developed to accelerate and facilitate use of techniques of computational fluid dynamics (CFD) in engineering environment. Addresses integration of all aspects of CFD analysis process, including definition of hardware surfaces, generation of computational grids, CFD flow solution, and postprocessing. Incorporates interfaces for integration of all hardware and software tools needed to perform complete CFD analysis. Includes tools for efficient definition of flow geometry, generation of computational grids, computation of flows on grids, and postprocessing of flow data. System accepts geometric input from any of three basic sources: computer-aided design (CAD), computer-aided engineering (CAE), or definition by user.

  12. Fault tree analysis: concepts and techniques

    International Nuclear Information System (INIS)

    Fussell, J.B.

    1976-01-01

    Concepts and techniques of fault tree analysis have been developed over the past decade and now predictions from this type analysis are important considerations in the design of many systems such as aircraft, ships and their electronic systems, missiles, and nuclear reactor systems. Routine, hardware-oriented fault tree construction can be automated; however, considerable effort is needed in this area to get the methodology into production status. When this status is achieved, the entire analysis of hardware systems will be automated except for the system definition step. Automated analysis is not undesirable; to the contrary, when verified on adequately complex systems, automated analysis could well become a routine analysis. It could also provide an excellent start for a more in-depth fault tree analysis that includes environmental effects, common mode failure, and human errors. The automated analysis is extremely fast and frees the analyst from the routine hardware-oriented fault tree construction, as well as eliminates logic errors and errors of oversight in this part of the analysis. Automated analysis then affords the analyst a powerful tool to allow his prime efforts to be devoted to unearthing more subtle aspects of the modes of failure of the system

  13. Ion backscattering techniques applied in materials science research

    International Nuclear Information System (INIS)

    Sood, D.K.

    1978-01-01

    The applications of Ion Backscattering Technique (IBT) to material analysis have expanded rapidly during the last decade. It is now regarded as an analysis tool indispensable for a versatile materials research program. The technique consists of simply shooting a beam of monoenergetic ions (usually 4 He + ions at about 2 MeV) onto a target, and measuring their energy distribution after backscattering at a fixed angle. Simple Rutherford scattering analysis of the backscattered ion spectrum yields information on the mass, the absolute amount and the depth profile of elements present upto a few microns of the target surface. The technique is nondestructive, quick, quantitative and the only known method of analysis which gives quantitative results without recourse to calibration standards. Its major limitations are the inability to separate elements of similar mass and a complete absence of chemical-binding information. A typical experimental set up and spectrum analysis have been described. Examples, some of them based on the work at the Bhabha Atomic Research Centre, Bombay, have been given to illustrate the applications of this technique to semiconductor technology, thin film materials science and nuclear energy materials. Limitations of IBT have been illustrated and a few remedies to partly overcome these limitations are presented. (auth.)

  14. Nonlinear analysis techniques of block masonry walls in nuclear power plants

    International Nuclear Information System (INIS)

    Hamid, A.A.; Harris, H.G.

    1986-01-01

    Concrete masonry walls have been used extensively in nuclear power plants as non-load bearing partitions serving as pipe supports, fire walls, radiation shielding barriers, and similar heavy construction separations. When subjected to earthquake loads, these walls should maintain their structural integrity. However, some of the walls do not meet design requirements based on working stress allowables. Consequently, utilities have used non-linear analysis techniques, such as the arching theory and the energy balance technique, to qualify such walls. This paper presents a critical review of the applicability of non-linear analysis techniques for both unreinforced and reinforced block masonry walls under seismic loading. These techniques are critically assessed in light of the performance of walls from limited available test data. It is concluded that additional test data are needed to justify the use of nonlinear analysis techniques to qualify block walls in nuclear power plants. (orig.)

  15. On-line and bulk analysis for the resource industries

    International Nuclear Information System (INIS)

    Lim, C.S.; Sowerby, B.D.; Tickner, J.R.; Madsen, I.C.

    2001-01-01

    Nuclear techniques are the basis of many CSIRO on-line and bulk analysis systems that are now widely used in the mineral and energy industries. The continuous analysis and rapid response of these systems have led to improved control of mining, processing and blending operations. This paper reviews recent developments in neutron, gamma-ray and X-ray techniques for on-line and bulk analysis by CSIRO Minerals including neutron techniques for the on-conveyor belt determination of the composition of cement raw meal, the on-line analysis of composition in pyrometallurgical applications, the on-conveyor belt determination of ash in coal, and the rapid and accurate determination of gold in bulk laboratory samples. The paper also discusses a new gamma-ray technique for the on-line determination of ash in coal and the application of X-ray diffraction techniques for the on-line determination of mineralogy in the cement industry

  16. Development of environmental sample analysis techniques for safeguards

    International Nuclear Information System (INIS)

    Magara, Masaaki; Hanzawa, Yukiko; Esaka, Fumitaka

    1999-01-01

    JAERI has been developing environmental sample analysis techniques for safeguards and preparing a clean chemistry laboratory with clean rooms. Methods to be developed are a bulk analysis and a particle analysis. In the bulk analysis, Inductively-Coupled Plasma Mass Spectrometer or Thermal Ionization Mass Spectrometer are used to measure nuclear materials after chemical treatment of sample. In the particle analysis, Electron Probe Micro Analyzer and Secondary Ion Mass Spectrometer are used for elemental analysis and isotopic analysis, respectively. The design of the clean chemistry laboratory has been carried out and construction will be completed by the end of March, 2001. (author)

  17. Rapid orthodontic treatment after the ridge-splitting technique--a combined surgical-orthodontic approach for implant site development: case report.

    Science.gov (United States)

    Amato, Francesco; Mirabella, A Davide; Borlizzi, Diego

    2012-08-01

    This article presents a clinical case of bilateral partial edentulism in the posterior mandible with severe horizontal and moderate vertical bone atrophy. A new technique using rapid orthodontics after ridge splitting is presented. The split-crest technique was carried out using piezosurgical instruments in the first molar and second premolar areas to widen the bone crest and open a channel for tooth movement. Immediately after, orthodontic appliances were used to move the first premolars distally and the second molars mesially into the surgical site. The rationale was to facilitate and accelerate orthodontic movement of the teeth, which is otherwise difficult in a cortical knife-edged ridge. The bone defect was filled with the alveolar bone of the adjacent teeth that were moved into the surgically opened path. Adequate bone volume for implant placement was generated in the first premolar area. Implants were then inserted, and the patient was rehabilitated.

  18. Motion Analysis Based on Invertible Rapid Transform

    Directory of Open Access Journals (Sweden)

    J. Turan

    1999-06-01

    Full Text Available This paper presents the results of a study on the use of invertible rapid transform (IRT for the motion estimation in a sequence of images. Motion estimation algorithms based on the analysis of the matrix of states (produced in the IRT calculation are described. The new method was used experimentally to estimate crowd and traffic motion from the image data sequences captured at railway stations and at high ways in large cities. The motion vectors may be used to devise a polar plot (showing velocity magnitude and direction for moving objects where the dominant motion tendency can be seen. The experimental results of comparison of the new motion estimation methods with other well known block matching methods (full search, 2D-log, method based on conventional (cross correlation (CC function or phase correlation (PC function for application of crowd motion estimation are also presented.

  19. Fabrication of channeled scaffolds with ordered array of micro-pores through microsphere leaching and indirect Rapid Prototyping technique.

    Science.gov (United States)

    Tan, J Y; Chua, C K; Leong, K F

    2013-02-01

    Advanced scaffold fabrication techniques such as Rapid Prototyping (RP) are generally recognized to be advantageous over conventional fabrication methods in terms architectural control and reproducibility. Yet, most RP techniques tend to suffer from resolution limitations which result in scaffolds with uncontrollable, random-size pores and low porosity, albeit having interconnected channels which is characteristically present in most RP scaffolds. With the increasing number of studies demonstrating the profound influences of scaffold pore architecture on cell behavior and overall tissue growth, a scaffold fabrication method with sufficient architectural control becomes imperative. The present study demonstrates the use of RP fabrication techniques to create scaffolds having interconnected channels as well as controllable micro-size pores. Adopted from the concepts of porogen leaching and indirect RP techniques, the proposed fabrication method uses monodisperse microspheres to create an ordered, hexagonal closed packed (HCP) array of micro-pores that surrounds the existing channels of the RP scaffold. The pore structure of the scaffold is shaped using a single sacrificial construct which comprises the microspheres and a dissolvable RP mold that were sintered together. As such, the size of pores as well as the channel configuration of the scaffold can be tailored based on the design of the RP mold and the size of microspheres used. The fabrication method developed in this work can be a promising alternative way of preparing scaffolds with customized pore structures that may be required for specific studies concerning cell-scaffold interactions.

  20. Biological sensing with surface-enhanced Raman spectroscopy (SERS) using a facile and rapid silver colloid-based synthesis technique

    Science.gov (United States)

    Smyth, C.; Mehigan, S.; Rakovich, Y. P.; Bell, S. E. J.; McCabe, E. M.

    2011-03-01

    Optical techniques towards the realisation of sensitive and selective biosensing platforms have received a considerable amount of attention in recent times. Techniques based on interferometry, surface plasmon resonance, field-effect transistors and waveguides have all proved popular, and in particular, spectroscopy offers a large range of options. Raman spectroscopy has always been viewed as an information rich technique in which the vibrational frequencies reveal a lot about the structure of a compound. The issue with Raman spectroscopy has traditionally been that its rather low cross section leads to poor limits-of-detection. In response to this problem, Surface-enhanced Raman Scattering (SERS), which increases sensitivity by bringing the sample in contact with many types of enhanceing substrates, has been developed. Here we discuss a facile and rapid technique for the detection of pterins using colloidal silver suspensions. Pteridine compounds are a family of biochemicals, heterocyclic in structure, and employed in nature as components of colour pigmentation and also as facilitators for many metabolic pathways, particularly those relating to the amino acid hydroxylases. In this work, xanthopterin, isoxanthopterin and 7,8- dihydrobiopterin have been examined whilst absorbed to SERS-active silver colloids. SERS, while far more sensitive than regular Raman spectroscopy, has its own issues relating to the reproducibility of substrates. In order to obtain quantitative data for the pteridine compounds mentioned above, exploratory studies of methods for introducing an internal standard for normalisation of the signals have been carried out.e

  1. Application of pattern recognition techniques to crime analysis

    Energy Technology Data Exchange (ETDEWEB)

    Bender, C.F.; Cox, L.A. Jr.; Chappell, G.A.

    1976-08-15

    The initial goal was to evaluate the capabilities of current pattern recognition techniques when applied to existing computerized crime data. Performance was to be evaluated both in terms of the system's capability to predict crimes and to optimize police manpower allocation. A relation was sought to predict the crime's susceptibility to solution, based on knowledge of the crime type, location, time, etc. The preliminary results of this work are discussed. They indicate that automatic crime analysis involving pattern recognition techniques is feasible, and that efforts to determine optimum variables and techniques are warranted. 47 figures (RWR)

  2. [Evaluation of a new blood gas analysis system: RapidPoint 500(®)].

    Science.gov (United States)

    Nicolas, Thierry; Cabrolier, Nadège; Bardonnet, Karine; Davani, Siamak

    2013-01-01

    We present here evaluation of a new blood gas analysis system, RapidPoint 500(®) (Siemens Healthcare Diagnostics). The aim of this research was to compare the ergonomics and analytical performances of this analyser with those of the RapidLab 1265 for the following parameters: pH, partial oxygen pressure, partial carbon dioxide pressure, sodium, potassium, ionized calcium, lactate and the CO-oximetry parameters: hemoglobin, oxyhemoglobin, carboxyhemoglobin, methemoglobin, reduced hemoglobin, neonatal bilirubin; as well as with the Dimension Vista 500 results for chloride and glucose. The Valtec protocol, recommended by the French Society of Clinical Biology (SFBC), was used to analyze the study results. The experiment was carried out over a period of one month in the Department of medical biochemistry. One hundred sixty five samples from adult patients admitted to the ER or hospitalized in intensive care were tested. The RapidPoint 500(®) was highly satisfactory from an ergonomic point of view. Intra-and inter- assay coefficients of variation (CV) with the three control levels were below those recommended by the SFBC for all parameters, and the comparative study gave coefficients of determination higher than 0.91. Taken together, the RapidPoint 500(®) appears fully satisfactory in terms of ergonomics and analytical performance.

  3. Application status of on-line nuclear techniques in analysis of coal quality

    International Nuclear Information System (INIS)

    Cai Shaohui

    1993-01-01

    Nuclear techniques are favourable for continuous on-line analysis, because they are fast, non-intrusive. They can be used in the adverse circumstances in coal industry. The paper reviews the application status of on-line nuclear techniques in analysis of coal quality and economic benefits derived from such techniques in developed countries

  4. Magnetic separation techniques in sample preparation for biological analysis: a review.

    Science.gov (United States)

    He, Jincan; Huang, Meiying; Wang, Dongmei; Zhang, Zhuomin; Li, Gongke

    2014-12-01

    Sample preparation is a fundamental and essential step in almost all the analytical procedures, especially for the analysis of complex samples like biological and environmental samples. In past decades, with advantages of superparamagnetic property, good biocompatibility and high binding capacity, functionalized magnetic materials have been widely applied in various processes of sample preparation for biological analysis. In this paper, the recent advancements of magnetic separation techniques based on magnetic materials in the field of sample preparation for biological analysis were reviewed. The strategy of magnetic separation techniques was summarized. The synthesis, stabilization and bio-functionalization of magnetic nanoparticles were reviewed in detail. Characterization of magnetic materials was also summarized. Moreover, the applications of magnetic separation techniques for the enrichment of protein, nucleic acid, cell, bioactive compound and immobilization of enzyme were described. Finally, the existed problems and possible trends of magnetic separation techniques for biological analysis in the future were proposed. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Rapid microbiology - raising awareness.

    Science.gov (United States)

    Bailie, Jonathan

    2016-01-01

    A 'high-level overview' of some of the emerging rapid microbiology technologies designed to help healthcare engineering and infection control teams working in hospitals and other healthcare facilities more rapidly identify potentially hazardous levels of waterborne microorganisms in their water systems, enabling them to take prompt remedial action, and a look at the some of the 'pros and cons' of such testing techniques, was given by Nalco technical director, Howard Barnes, the vice-chair of the Legionella Control Association (LCA), at a recent LCA open day. HEJ editor, Jonathan Bailie, reports.

  6. A field technique for rapid lithological discrimination and ore mineral ...

    Indian Academy of Sciences (India)

    This work illustrates the efficiency of field spectroscopy for rapid identification of minerals in ore body, alteration zone and host rocks. The adopted procedure involves collection of field spectra, their processing for noise, spectral matching and spectral un-mixing with selected library end-members. Average weighted spectral ...

  7. Principles, Techniques, and Applications of Tissue Microfluidics

    Science.gov (United States)

    Wade, Lawrence A.; Kartalov, Emil P.; Shibata, Darryl; Taylor, Clive

    2011-01-01

    The principle of tissue microfluidics and its resultant techniques has been applied to cell analysis. Building microfluidics to suit a particular tissue sample would allow the rapid, reliable, inexpensive, highly parallelized, selective extraction of chosen regions of tissue for purposes of further biochemical analysis. Furthermore, the applicability of the techniques ranges beyond the described pathology application. For example, they would also allow the posing and successful answering of new sets of questions in many areas of fundamental research. The proposed integration of microfluidic techniques and tissue slice samples is called "tissue microfluidics" because it molds the microfluidic architectures in accordance with each particular structure of each specific tissue sample. Thus, microfluidics can be built around the tissues, following the tissue structure, or alternatively, the microfluidics can be adapted to the specific geometry of particular tissues. By contrast, the traditional approach is that microfluidic devices are structured in accordance with engineering considerations, while the biological components in applied devices are forced to comply with these engineering presets.

  8. Performance analysis of clustering techniques over microarray data: A case study

    Science.gov (United States)

    Dash, Rasmita; Misra, Bijan Bihari

    2018-03-01

    Handling big data is one of the major issues in the field of statistical data analysis. In such investigation cluster analysis plays a vital role to deal with the large scale data. There are many clustering techniques with different cluster analysis approach. But which approach suits a particular dataset is difficult to predict. To deal with this problem a grading approach is introduced over many clustering techniques to identify a stable technique. But the grading approach depends on the characteristic of dataset as well as on the validity indices. So a two stage grading approach is implemented. In this study the grading approach is implemented over five clustering techniques like hybrid swarm based clustering (HSC), k-means, partitioning around medoids (PAM), vector quantization (VQ) and agglomerative nesting (AGNES). The experimentation is conducted over five microarray datasets with seven validity indices. The finding of grading approach that a cluster technique is significant is also established by Nemenyi post-hoc hypothetical test.

  9. Techniques for Automated Performance Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Marcus, Ryan C. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2014-09-02

    The performance of a particular HPC code depends on a multitude of variables, including compiler selection, optimization flags, OpenMP pool size, file system load, memory usage, MPI configuration, etc. As a result of this complexity, current predictive models have limited applicability, especially at scale. We present a formulation of scientific codes, nodes, and clusters that reduces complex performance analysis to well-known mathematical techniques. Building accurate predictive models and enhancing our understanding of scientific codes at scale is an important step towards exascale computing.

  10. High-Resolution Melt Analysis for Rapid Comparison of Bacterial Community Compositions

    DEFF Research Database (Denmark)

    Hjelmsø, Mathis Hjort; Hansen, Lars Hestbjerg; Bælum, Jacob

    2014-01-01

    In the study of bacterial community composition, 16S rRNA gene amplicon sequencing is today among the preferred methods of analysis. The cost of nucleotide sequence analysis, including requisite computational and bioinformatic steps, however, takes up a large part of many research budgets. High......-resolution melt (HRM) analysis is the study of the melt behavior of specific PCR products. Here we describe a novel high-throughput approach in which we used HRM analysis targeting the 16S rRNA gene to rapidly screen multiple complex samples for differences in bacterial community composition. We hypothesized...... that HRM analysis of amplified 16S rRNA genes from a soil ecosystem could be used as a screening tool to identify changes in bacterial community structure. This hypothesis was tested using a soil microcosm setup exposed to a total of six treatments representing different combinations of pesticide...

  11. Rapid fluorescence detection of pathogenic bacteria using magnetic enrichment technique combined with magnetophoretic chromatography.

    Science.gov (United States)

    Che, Yulan; Xu, Yi; Wang, Renjie; Chen, Li

    2017-08-01

    A rapid and sensitive analytical method was developed to detect pathogenic bacteria which combined magnetic enrichment, fluorescence labeling with polyethylene glycol (PEG) magnetophoretic chromatography. As pathogenic bacteria usually exist in complex matrixes at low concentration, an efficient enrichment is essential for diagnosis. In order to capture series types of pathogenic bacteria in samples, amino-modified magnetic nanoparticles (Fe 3 O 4 @SiO 2 -NH 2 ) were prepared for efficient enrichment by the electrostatic interaction with pathogenic bacteria. It was shown that the capture efficiency reached up to 95.4% for Escherichia coli (E. coli). Furthermore, quantitative analysis of the bacteria was achieved by using acridine orange (AO) as a fluorescence probe for the captured E. coli due to its ability of staining series types of bacteria and rapid labeling. In order to remove the free magnetic nanoparticles and redundant fluorescent reagent, the labeled suspension was poured into a PEG separation column and was separated by applying an external magnetic field. The presence of 100 cfu mL -1 E. coli could be detected for semi-quantitative analysis by observing the separation column with the naked eye, and the concentration could be further evaluated by fluorescence detection. All the above processes were finished within 80 min. It was demonstrated that a good linear relationship existed between the fluorescence intensity and the concentration of E. coli ranging from 10 2 to 10 6  cfu mL -1 , with a detection limit of 100 cfu mL -1 when E. coli acted as target bacteria. The recovery rate of E. coli was 93.6∼102.0% in tap water and cooked meat samples, and the RSD was lower than 7% (n = 6); the result coincided with the conventional plate count method. Graphical abstract ᅟ.

  12. Rapid determination of sugar level in snack products using infrared spectroscopy.

    Science.gov (United States)

    Wang, Ting; Rodriguez-Saona, Luis E

    2012-08-01

    Real-time spectroscopic methods can provide a valuable window into food manufacturing to permit optimization of production rate, quality and safety. There is a need for cutting edge sensor technology directed at improving efficiency, throughput and reliability of critical processes. The aim of the research was to evaluate the feasibility of infrared systems combined with chemometric analysis to develop rapid methods for determination of sugars in cereal products. Samples were ground and spectra were collected using a mid-infrared (MIR) spectrometer equipped with a triple-bounce ZnSe MIRacle attenuated total reflectance accessory or Fourier transform near infrared (NIR) system equipped with a diffuse reflection-integrating sphere. Sugar contents were determined using a reference HPLC method. Partial least squares regression (PLSR) was used to create cross-validated calibration models. The predictability of the models was evaluated on an independent set of samples and compared with reference techniques. MIR and NIR spectra showed characteristic absorption bands for sugars, and generated excellent PLSR models (sucrose: SEP 0.96). Multivariate models accurately and precisely predicted sugar level in snacks allowing for rapid analysis. This simple technique allows for reliable prediction of quality parameters, and automation enabling food manufacturers for early corrective actions that will ultimately save time and money while establishing a uniform quality. The U.S. snack food industry generates billions of dollars in revenue each year and vibrational spectroscopic methods combined with pattern recognition analysis could permit optimization of production rate, quality, and safety of many food products. This research showed that infrared spectroscopy is a powerful technique for near real-time (approximately 1 min) assessment of sugar content in various cereal products. © 2012 Institute of Food Technologists®

  13. Prompt Gamma Activation Analysis (PGAA): Technique of choice for nondestructive bulk analysis of returned comet samples

    International Nuclear Information System (INIS)

    Lindstrom, D.J.; Lindstrom, R.M.

    1989-01-01

    Prompt gamma activation analysis (PGAA) is a well-developed analytical technique. The technique involves irradiation of samples in an external neutron beam from a nuclear reactor, with simultaneous counting of gamma rays produced in the sample by neutron capture. Capture of neutrons leads to excited nuclei which decay immediately with the emission of energetic gamma rays to the ground state. PGAA has several advantages over other techniques for the analysis of cometary materials: (1) It is nondestructive; (2) It can be used to determine abundances of a wide variety of elements, including most major and minor elements (Na, Mg, Al, Si, P, K, Ca, Ti, Cr, Mn, Fe, Co, Ni), volatiles (H, C, N, F, Cl, S), and some trace elements (those with high neutron capture cross sections, including B, Cd, Nd, Sm, and Gd); and (3) It is a true bulk analysis technique. Recent developments should improve the technique's sensitivity and accuracy considerably

  14. A review on applications of the wavelet transform techniques in spectral analysis

    International Nuclear Information System (INIS)

    Medhat, M.E.; Albdel-hafiez, A.; Hassan, M.F.; Ali, M.A.; Awaad, Z.

    2004-01-01

    Starting from 1989, a new technique known as wavelet transforms (WT) has been applied successfully for analysis of different types of spectra. WT offers certain advantages over Fourier transforms for analysis of signals. A review of using this technique through different fields of elemental analysis is presented

  15. The rapid determination of americium curium, and uranium in urine by ultrafiltration

    International Nuclear Information System (INIS)

    Stradling, G.N.; Popplewell, D.S.; Ham, G.J.; Griffin, R.

    1975-01-01

    The rapid ultrafiltration method developed for the assay of plutonium has been extended to the determination of americium, curium and uranium in urine. The limits of detection for americium and curium, and uranium are 0.09 and 0.12 dm -1 l -1 respectively, and the analysis time excluding counting less than 2 hours. The method can therefor be effectively used as a rapid screening procedure. When the reference level for plutonium is exceeded, the α activity may require to be characterised. The single ultrafiltration technique must be modified for turbid urine samples. The method is inappropriate, except for uranium, when the urine contains DTPA. (author)

  16. Advances in oriental document analysis and recognition techniques

    CERN Document Server

    Lee, Seong-Whan

    1999-01-01

    In recent years, rapid progress has been made in computer processing of oriental languages, and the research developments in this area have resulted in tremendous changes in handwriting processing, printed oriental character recognition, document analysis and recognition, automatic input methodologies for oriental languages, etc. Advances in computer processing of oriental languages can also be seen in multimedia computing and the World Wide Web. Many of the results in those domains are presented in this book.

  17. Novel technique for rapid screening of tinnitus in rats

    Science.gov (United States)

    Turner, Jeremy G.; Brozoski, Thomas J.; Parrish, Jennifer L.; Bauer, Carol A.; Hughes, Larry F.; Caspary, Donald M.

    2005-04-01

    Measuring tinnitus in laboratory animals is difficult, involving weeks or months of operant training. Preliminary data suggest that rapid screening for tinnitus in rats can be accomplished using an unconditioned acoustic startle reflex. In control animals, a gap in an otherwise constant acoustic background inhibits a subsequent startle response to a sound impulse. If, however, the background signal is qualitatively similar to the animal's tinnitus, poorer detection of the gap and less inhibition of the startle might be expected. Fourteen animals with putative tinnitus at 10 kHz and 13 control animals were tested for gap detection using three different background signals: broadband noise, and filtered bandpass noise centered either at 16 kHz (15.5-16.5 kHz) or at their suspected tinnitus locus of 10 kHz (9.5-10.5 kHz). As predicted, animals with evidence of tinnitus exhibited significantly worse gap detection at 10 kHz, and were not significantly different than control animals at 16 kHz and broadband noise. These results suggest a new methodology for rapidly detecting tinnitus in individual animals. Equipment donated by Hamilton-Kinder Inc Behavioral Testing Systems in the memory of SIU graduate Dorothy Jean Kinder (Walker). [Work supported by NIH grants AG023910-01 (JT), DC4830 (TB & CB), and DC00151 (DC).

  18. Rapid Analysis Procedures for Triglycerides and Fatty Acids as Pentyl and Phenethyl Esters for the Detection of Butter Adulteration Using Chromatographic Techniques

    Directory of Open Access Journals (Sweden)

    Daniele Naviglio

    2017-01-01

    Full Text Available This paper presents the development of three methods for quality control, fraud detection, and authentication of butter fat and other oils/fats using chromatographic techniques, with one method for triglycerides and two methods for fatty acids (FAs. The procedure for the analysis of triglycerides requires only dissolution of the sample in n-hexane and gas chromatography (GC analysis using a capillary column. The second method is based on the transesterification of triglycerides as pentyl esters in a single-step reaction using sodium pentanoate in pentanol. The reaction proceeds at room temperature and is similar to the potassium hydroxide-catalysed transesterification of triglycerides with methanol and even more similar to the sodium methoxide method and sodium butanoate method. The advantage of using pentyl esters includes reducing the volatility of short-chain FAs, and substantial recoveries were obtained compared with methyl ester analysis. The third method involves the transesterification of triglycerides in fat through reaction with 2-phenylethanol in a single step; 2-phenylethanol possesses a chromophore, and the phenethyl esters formed are analysed by high-performance liquid chromatography (HPLC with UV detection.

  19. Analysis technique for controlling system wavefront error with active/adaptive optics

    Science.gov (United States)

    Genberg, Victor L.; Michels, Gregory J.

    2017-08-01

    The ultimate goal of an active mirror system is to control system level wavefront error (WFE). In the past, the use of this technique was limited by the difficulty of obtaining a linear optics model. In this paper, an automated method for controlling system level WFE using a linear optics model is presented. An error estimate is included in the analysis output for both surface error disturbance fitting and actuator influence function fitting. To control adaptive optics, the technique has been extended to write system WFE in state space matrix form. The technique is demonstrated by example with SigFit, a commercially available tool integrating mechanical analysis with optical analysis.

  20. Diagnostic accuracy of dynamic contrast-enhanced MR imaging of renal masses with rapid-acquisition spin-echo technique

    International Nuclear Information System (INIS)

    Eilenberg, S.S.; Lee, J.K.T.; Brown, J.J.; Heiken, J.P.; Mirowitz, S.A.

    1990-01-01

    This paper compares the diagnostic accuracy of Gd-DTPA-enhanced rapid-acquisition spin-echo (RASE) imaging with standard spin-echo techniques for detecting renal cysts and solid renal neoplasms. RASE imaging combines a short TR (275 msec)/short TE (10 msec), single excitation pulse sequence with half-Fourier data sampling. Eighteen patients with CT evidence of renal masses were first evaluated with standard T1-and T2-weighted SE sequences. Pre- and serial postcontrast (Cd-DTPA, 0.1 mmol./kg) RASE sequences were then performed during suspended respiration. A final set of postcontrast images was obtained with the standard T1-weighted SE sequence. Each set of MR images was first reviewed separately (ie, T1, T2, pre- and post-contrast RASE, etc)

  1. Rapid DNA analysis for automated processing and interpretation of low DNA content samples.

    Science.gov (United States)

    Turingan, Rosemary S; Vasantgadkar, Sameer; Palombo, Luke; Hogan, Catherine; Jiang, Hua; Tan, Eugene; Selden, Richard F

    2016-01-01

    Short tandem repeat (STR) analysis of casework samples with low DNA content include those resulting from the transfer of epithelial cells from the skin to an object (e.g., cells on a water bottle, or brim of a cap), blood spatter stains, and small bone and tissue fragments. Low DNA content (LDC) samples are important in a wide range of settings, including disaster response teams to assist in victim identification and family reunification, military operations to identify friend or foe, criminal forensics to identify suspects and exonerate the innocent, and medical examiner and coroner offices to identify missing persons. Processing LDC samples requires experienced laboratory personnel, isolated workstations, and sophisticated equipment, requires transport time, and involves complex procedures. We present a rapid DNA analysis system designed specifically to generate STR profiles from LDC samples in field-forward settings by non-technical operators. By performing STR in the field, close to the site of collection, rapid DNA analysis has the potential to increase throughput and to provide actionable information in real time. A Low DNA Content BioChipSet (LDC BCS) was developed and manufactured by injection molding. It was designed to function in the fully integrated Accelerated Nuclear DNA Equipment (ANDE) instrument previously designed for analysis of buccal swab and other high DNA content samples (Investigative Genet. 4(1):1-15, 2013). The LDC BCS performs efficient DNA purification followed by microfluidic ultrafiltration of the purified DNA, maximizing the quantity of DNA available for subsequent amplification and electrophoretic separation and detection of amplified fragments. The system demonstrates accuracy, precision, resolution, signal strength, and peak height ratios appropriate for casework analysis. The LDC rapid DNA analysis system is effective for the generation of STR profiles from a wide range of sample types. The technology broadens the range of sample

  2. Research on digital multi-channel pulse height analysis techniques

    International Nuclear Information System (INIS)

    Xiao Wuyun; Wei Yixiang; Ai Xianyun; Ao Qi

    2005-01-01

    Multi-channel pulse height analysis techniques are developing in the direction of digitalization. Based on digital signal processing techniques, digital multi-channel analyzers are characterized by powerful pulse processing ability, high throughput, improved stability and flexibility. This paper analyzes key techniques of digital nuclear pulse processing. With MATLAB software, main algorithms are simulated, such as trapezoidal shaping, digital baseline estimation, digital pole-zero/zero-pole compensation, poles and zeros identification. The preliminary general scheme of digital MCA is discussed, as well as some other important techniques about its engineering design. All these lay the foundation of developing homemade digital nuclear spectrometers. (authors)

  3. A mass spectrometer for the rapid analysis of gaseous mixtures

    International Nuclear Information System (INIS)

    Cassignol, C.; Ortel, Y.; Taieb, J.

    1950-01-01

    A mass spectrometer for leak detection and rapid gas analysis were constructed, having the characteristics and several structural features of a simple instrument described by Siry in Rev. Sri. Instruments. 540 (1947). Although exhibiting a good resolving power, the apparatus, which has no ion lenses and whose electrodes can be regulated during the performance, has not been sufficiently tested. Since several design defects have been discovered, it will probably be rebuilt with various improvements (ion source outside the magnetic field, modified circuits, etc.). (author)

  4. Characterization of decommissioned reactor internals: Monte Carlo analysis technique

    International Nuclear Information System (INIS)

    Reid, B.D.; Love, E.F.; Luksic, A.T.

    1993-03-01

    This study discusses computer analysis techniques for determining activation levels of irradiated reactor component hardware to yield data for the Department of Energy's Greater-Than-Class C Low-Level Radioactive Waste Program. The study recommends the Monte Carlo Neutron/Photon (MCNP) computer code as the best analysis tool for this application and compares the technique to direct sampling methodology. To implement the MCNP analysis, a computer model would be developed to reflect the geometry, material composition, and power history of an existing shutdown reactor. MCNP analysis would then be performed using the computer model, and the results would be validated by comparison to laboratory analysis results from samples taken from the shutdown reactor. The report estimates uncertainties for each step of the computational and laboratory analyses; the overall uncertainty of the MCNP results is projected to be ±35%. The primary source of uncertainty is identified as the material composition of the components, and research is suggested to address that uncertainty

  5. Application of Multivariable Statistical Techniques in Plant-wide WWTP Control Strategies Analysis

    DEFF Research Database (Denmark)

    Flores Alsina, Xavier; Comas, J.; Rodríguez-Roda, I.

    2007-01-01

    The main objective of this paper is to present the application of selected multivariable statistical techniques in plant-wide wastewater treatment plant (WWTP) control strategies analysis. In this study, cluster analysis (CA), principal component analysis/factor analysis (PCA/FA) and discriminant...... analysis (DA) are applied to the evaluation matrix data set obtained by simulation of several control strategies applied to the plant-wide IWA Benchmark Simulation Model No 2 (BSM2). These techniques allow i) to determine natural groups or clusters of control strategies with a similar behaviour, ii......) to find and interpret hidden, complex and casual relation features in the data set and iii) to identify important discriminant variables within the groups found by the cluster analysis. This study illustrates the usefulness of multivariable statistical techniques for both analysis and interpretation...

  6. Preconditioned conjugate gradient technique for the analysis of symmetric anisotropic structures

    Science.gov (United States)

    Noor, Ahmed K.; Peters, Jeanne M.

    1987-01-01

    An efficient preconditioned conjugate gradient (PCG) technique and a computational procedure are presented for the analysis of symmetric anisotropic structures. The technique is based on selecting the preconditioning matrix as the orthotropic part of the global stiffness matrix of the structure, with all the nonorthotropic terms set equal to zero. This particular choice of the preconditioning matrix results in reducing the size of the analysis model of the anisotropic structure to that of the corresponding orthotropic structure. The similarities between the proposed PCG technique and a reduction technique previously presented by the authors are identified and exploited to generate from the PCG technique direct measures for the sensitivity of the different response quantities to the nonorthotropic (anisotropic) material coefficients of the structure. The effectiveness of the PCG technique is demonstrated by means of a numerical example of an anisotropic cylindrical panel.

  7. Technique Triangulation for Validation in Directed Content Analysis

    Directory of Open Access Journals (Sweden)

    Áine M. Humble PhD

    2009-09-01

    Full Text Available Division of labor in wedding planning varies for first-time marriages, with three types of couples—traditional, transitional, and egalitarian—identified, but nothing is known about wedding planning for remarrying individuals. Using semistructured interviews, the author interviewed 14 couples in which at least one person had remarried and used directed content analysis to investigate the extent to which the aforementioned typology could be transferred to this different context. In this paper she describes how a triangulation of analytic techniques provided validation for couple classifications and also helped with moving beyond “blind spots” in data analysis. Analytic approaches were the constant comparative technique, rank order comparison, and visual representation of coding, using MAXQDA 2007's tool called TextPortraits.

  8. A rapid method of radium-226 analysis in water samples using an alpha spectroscopic technique

    International Nuclear Information System (INIS)

    Lim, T.P.

    1981-01-01

    A fast, reliable and accurate method for radium-226 determination in environmental water samples has been devised, using an alpha spectroscopic technique. The correlation between barium-133 and radium-226 in the barium-radium sulphate precipitation mechanism was studied and in the limited experimental recovery range, the coefficient of correlation was r = 0.986. A self-absorption study for various barium carrier concentrations was also undertaken to obtain the least broadening of alpha energy line widths. An optimum value of 0.3 mg barium carrier was obtained for chemical recovery in the range of 85 percent. (auth)

  9. Sensitivity analysis technique for application to deterministic models

    International Nuclear Information System (INIS)

    Ishigami, T.; Cazzoli, E.; Khatib-Rahbar, M.; Unwin, S.D.

    1987-01-01

    The characterization of sever accident source terms for light water reactors should include consideration of uncertainties. An important element of any uncertainty analysis is an evaluation of the sensitivity of the output probability distributions reflecting source term uncertainties to assumptions regarding the input probability distributions. Historically, response surface methods (RSMs) were developed to replace physical models using, for example, regression techniques, with simplified models for example, regression techniques, with simplified models for extensive calculations. The purpose of this paper is to present a new method for sensitivity analysis that does not utilize RSM, but instead relies directly on the results obtained from the original computer code calculations. The merits of this approach are demonstrated by application of the proposed method to the suppression pool aerosol removal code (SPARC), and the results are compared with those obtained by sensitivity analysis with (a) the code itself, (b) a regression model, and (c) Iman's method

  10. Study of analysis techniques of thermoluminescent dosimeters response

    International Nuclear Information System (INIS)

    Castro, Walber Amorim

    2002-01-01

    The Personal Monitoring Service of the Centro Regional de Ciencias Nucleares uses in its dosemeter the TLD 700 material . The TLD's analysis is carried out using a Harshaw-Bicron model 6600 automatic reading system. This system uses dry air instead of the traditional gaseous nitrogen. This innovation brought advantages to the service but introduced uncertainties in the reference of the detectors; one of these was observed for doses below 0,5 mSv. In this work different techniques of analysis of the TLD response were investigated and compared, involving dose values in this interval. These techniques include thermal pre-treatment, and different kinds of the glow curves analysis methods were investigated. Obtained results showed the necessity of developing a specific software that permits the automatic background subtraction for the glow curves for each dosemeter . This software was developed and it bean tested. Preliminary results showed the software increase the response reproducibility. (author)

  11. Rapid die manufacturing using direct laser metal deposition

    CSIR Research Space (South Africa)

    Pereira, MFVT

    2009-01-01

    Full Text Available This paper highlights the work undertaken at the CSIR on the issue of rapid die manufacturing through the application and evaluation of a rapid prototyping technique and coating technologies applied to die components of a high pressure casting die...

  12. Dosimetric comparison of helical tomotherapy, RapidArc, and a novel IMRT and Arc technique for esophageal carcinoma

    International Nuclear Information System (INIS)

    Martin, Spencer; Chen, Jeff Z.; Rashid Dar, A.; Yartsev, Slav

    2011-01-01

    Purpose: To compare radiotherapy treatment plans for mid- and distal-esophageal cancer with primary involvement of the gastroesophageal (GE) junction using a novel IMRT and Arc technique (IMRT and Arc), helical tomotherapy (HT), and RapidArc (RA1 and RA2). Methods and materials: Eight patients treated on HT for locally advanced esophageal cancer with radical intent were re-planned for RA and IMRT and Arc. RA plans employed single and double arcs (RA1 and RA2, respectively), while IMRT and Arc plans had four fixed-gantry IMRT fields and a conformal arc. Dose-volume histogram statistics, dose uniformity, and dose homogeneity were analyzed to compare treatment plans. Results: RA2 plans showed significant improvement over RA1 plans in terms of OAR dose and PTV dose uniformity and homogeneity. HT plan provided best dose uniformity (p = 0.001) and dose homogeneity (p = 0.002) to planning target volume (PTV), while IMRT and Arc and RA2 plans gave lowest dose to lungs among four radiotherapy techniques with acceptable PTV dose coverage. Mean V 10 of the lungs was significantly reduced by the RA2 plans compared to IMRT and Arc (40.3%, p = 0.001) and HT (66.2%, p 15 of the lungs for the RA2 plans also showed significant improvement over the IMRT and Arc (25.2%, p = 0.042) and HT (34.8%, p = 0.027) techniques. These improvements came at the cost of higher doses to the heart volume compared to HT and IMRT and Arc techniques. Mean lung dose (MLD) for the IMRT and Arc technique (21.2 ± 5.0% of prescription dose) was significantly reduced compared to HT (26.3%, p = 0.004), RA1 (23.3%, p = 0.028), and RA2 (23.2%, p = 0.017) techniques. Conclusion: The IMRT and Arc technique is a good option for treating esophageal cancer with thoracic involvement. It achieved optimal low dose to the lungs and heart with acceptable PTV coverage. HT is a good option for treating esophageal cancer with little thoracic involvement as it achieves superior dose conformality and uniformity. The RA2

  13. Accurate and Rapid Differentiation of Acinetobacter baumannii Strains by Raman Spectroscopy: a Comparative Study.

    Science.gov (United States)

    Ghebremedhin, Meron; Heitkamp, Rae; Yesupriya, Shubha; Clay, Bradford; Crane, Nicole J

    2017-08-01

    In recent years, matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has become the standard for routine bacterial species identification due to its rapidity and low costs for consumables compared to those of traditional DNA-based methods. However, it has been observed that strains of some bacterial species, such as Acinetobacter baumannii strains, cannot be reliably identified using mass spectrometry (MS). Raman spectroscopy is a rapid technique, as fast as MALDI-TOF, and has been shown to accurately identify bacterial strains and species. In this study, we compared hierarchical clustering results for MS, genomic, and antimicrobial susceptibility test data to hierarchical clustering results from Raman spectroscopic data for 31 A. baumannii clinical isolates labeled according to their pulsed-field gel electrophoresis data for strain differentiation. In addition to performing hierarchical cluster analysis (HCA), multiple chemometric methods of analysis, including principal-component analysis (PCA) and partial least-squares discriminant analysis (PLSDA), were performed on the MS and Raman spectral data, along with a variety of spectral preprocessing techniques for best discriminative results. Finally, simple HCA algorithms were performed on all of the data sets to explore the relationships between, and natural groupings of, the strains and to compare results for the four data sets. To obtain numerical comparison values of the clustering results, the external cluster evaluation criteria of the Rand index of the HCA dendrograms were calculated. With a Rand index value of 0.88, Raman spectroscopy outperformed the other techniques, including MS (with a Rand index value of 0.58). Copyright © 2017 Ghebremedhin et al.

  14. Nuclear techniques of analysis in diamond synthesis and annealing

    Energy Technology Data Exchange (ETDEWEB)

    Jamieson, D. N.; Prawer, S.; Gonon, P.; Walker, R.; Dooley, S.; Bettiol, A.; Pearce, J. [Melbourne Univ., Parkville, VIC (Australia). School of Physics

    1996-12-31

    Nuclear techniques of analysis have played an important role in the study of synthetic and laser annealed diamond. These measurements have mainly used ion beam analysis with a focused MeV ion beam in a nuclear microprobe system. A variety of techniques have been employed. One of the most important is nuclear elastic scattering, sometimes called non-Rutherford scattering, which has been used to accurately characterise diamond films for thickness and composition. This is possible by the use of a database of measured scattering cross sections. Recently, this work has been extended and nuclear elastic scattering cross sections for both natural boron isotopes have been measured. For radiation damaged diamond, a focused laser annealing scheme has been developed which produces near complete regrowth of MeV phosphorus implanted diamonds. In the laser annealed regions, proton induced x-ray emission has been used to show that 50 % of the P atoms occupy lattice sites. This opens the way to produce n-type diamond for microelectronic device applications. All these analytical applications utilize a focused MeV microbeam which is ideally suited for diamond analysis. This presentation reviews these applications, as well as the technology of nuclear techniques of analysis for diamond with a focused beam. 9 refs., 6 figs.

  15. Reliability analysis of large scaled structures by optimization technique

    International Nuclear Information System (INIS)

    Ishikawa, N.; Mihara, T.; Iizuka, M.

    1987-01-01

    This paper presents a reliability analysis based on the optimization technique using PNET (Probabilistic Network Evaluation Technique) method for the highly redundant structures having a large number of collapse modes. This approach makes the best use of the merit of the optimization technique in which the idea of PNET method is used. The analytical process involves the minimization of safety index of the representative mode, subjected to satisfaction of the mechanism condition and of the positive external work. The procedure entails the sequential performance of a series of the NLP (Nonlinear Programming) problems, where the correlation condition as the idea of PNET method pertaining to the representative mode is taken as an additional constraint to the next analysis. Upon succeeding iterations, the final analysis is achieved when a collapse probability at the subsequent mode is extremely less than the value at the 1st mode. The approximate collapse probability of the structure is defined as the sum of the collapse probabilities of the representative modes classified by the extent of correlation. Then, in order to confirm the validity of the proposed method, the conventional Monte Carlo simulation is also revised by using the collapse load analysis. Finally, two fairly large structures were analyzed to illustrate the scope and application of the approach. (orig./HP)

  16. Nuclear techniques of analysis in diamond synthesis and annealing

    Energy Technology Data Exchange (ETDEWEB)

    Jamieson, D N; Prawer, S; Gonon, P; Walker, R; Dooley, S; Bettiol, A; Pearce, J [Melbourne Univ., Parkville, VIC (Australia). School of Physics

    1997-12-31

    Nuclear techniques of analysis have played an important role in the study of synthetic and laser annealed diamond. These measurements have mainly used ion beam analysis with a focused MeV ion beam in a nuclear microprobe system. A variety of techniques have been employed. One of the most important is nuclear elastic scattering, sometimes called non-Rutherford scattering, which has been used to accurately characterise diamond films for thickness and composition. This is possible by the use of a database of measured scattering cross sections. Recently, this work has been extended and nuclear elastic scattering cross sections for both natural boron isotopes have been measured. For radiation damaged diamond, a focused laser annealing scheme has been developed which produces near complete regrowth of MeV phosphorus implanted diamonds. In the laser annealed regions, proton induced x-ray emission has been used to show that 50 % of the P atoms occupy lattice sites. This opens the way to produce n-type diamond for microelectronic device applications. All these analytical applications utilize a focused MeV microbeam which is ideally suited for diamond analysis. This presentation reviews these applications, as well as the technology of nuclear techniques of analysis for diamond with a focused beam. 9 refs., 6 figs.

  17. Nuclear techniques of analysis in diamond synthesis and annealing

    International Nuclear Information System (INIS)

    Jamieson, D. N.; Prawer, S.; Gonon, P.; Walker, R.; Dooley, S.; Bettiol, A.; Pearce, J.

    1996-01-01

    Nuclear techniques of analysis have played an important role in the study of synthetic and laser annealed diamond. These measurements have mainly used ion beam analysis with a focused MeV ion beam in a nuclear microprobe system. A variety of techniques have been employed. One of the most important is nuclear elastic scattering, sometimes called non-Rutherford scattering, which has been used to accurately characterise diamond films for thickness and composition. This is possible by the use of a database of measured scattering cross sections. Recently, this work has been extended and nuclear elastic scattering cross sections for both natural boron isotopes have been measured. For radiation damaged diamond, a focused laser annealing scheme has been developed which produces near complete regrowth of MeV phosphorus implanted diamonds. In the laser annealed regions, proton induced x-ray emission has been used to show that 50 % of the P atoms occupy lattice sites. This opens the way to produce n-type diamond for microelectronic device applications. All these analytical applications utilize a focused MeV microbeam which is ideally suited for diamond analysis. This presentation reviews these applications, as well as the technology of nuclear techniques of analysis for diamond with a focused beam. 9 refs., 6 figs

  18. Rapid automatic keyword extraction for information retrieval and analysis

    Science.gov (United States)

    Rose, Stuart J [Richland, WA; Cowley,; E, Wendy [Richland, WA; Crow, Vernon L [Richland, WA; Cramer, Nicholas O [Richland, WA

    2012-03-06

    Methods and systems for rapid automatic keyword extraction for information retrieval and analysis. Embodiments can include parsing words in an individual document by delimiters, stop words, or both in order to identify candidate keywords. Word scores for each word within the candidate keywords are then calculated based on a function of co-occurrence degree, co-occurrence frequency, or both. Based on a function of the word scores for words within the candidate keyword, a keyword score is calculated for each of the candidate keywords. A portion of the candidate keywords are then extracted as keywords based, at least in part, on the candidate keywords having the highest keyword scores.

  19. Clinical utilisation of a rapid low-pass whole genome sequencing technique for the diagnosis of aneuploidy in human embryos prior to implantation.

    Science.gov (United States)

    Wells, Dagan; Kaur, Kulvinder; Grifo, Jamie; Glassner, Michael; Taylor, Jenny C; Fragouli, Elpida; Munne, Santiago

    2014-08-01

    The majority of human embryos created using in vitro fertilisation (IVF) techniques are aneuploid. Comprehensive chromosome screening methods, applicable to single cells biopsied from preimplantation embryos, allow reliable identification and transfer of euploid embryos. Recently, randomised trials using such methods have indicated that aneuploidy screening improves IVF success rates. However, the high cost of testing has restricted the availability of this potentially beneficial strategy. This study aimed to harness next-generation sequencing (NGS) technology, with the intention of lowering the costs of preimplantation aneuploidy screening. Embryo biopsy, whole genome amplification and semiconductor sequencing. A rapid (cost only two-thirds that of the most widely used method for embryo aneuploidy detection. Validation involved blinded analysis of 54 cells from cell lines or biopsies from human embryos. Sensitivity and specificity were 100%. The method was applied clinically, assisting in the selection of euploid embryos in two IVF cycles, producing healthy children in both cases. The NGS approach was also able to reveal specified mutations in the nuclear or mitochondrial genomes in parallel with chromosome assessment. Interestingly, elevated mitochondrial DNA content was associated with aneuploidy (pcost diagnosis of aneuploidy in cells from human preimplantation embryos and is rapid enough to allow testing without embryo cryopreservation. The method described also has the potential to shed light on other aspects of embryo genetics of relevance to health and viability. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  20. HIV Rapid Testing in a VA Emergency Department Setting: Cost Analysis at 5 Years.

    Science.gov (United States)

    Knapp, Herschel; Chan, Kee

    2015-07-01

    To conduct a comprehensive cost-minimization analysis to comprehend the financial attributes of the first 5 years of an implementation wherein emergency department (ED) registered nurses administered HIV oral rapid tests to patients. A health science research implementation team coordinated with ED stakeholders and staff to provide training, implementation guidelines, and support to launch ED registered nurse-administered HIV oral rapid testing. Deidentified quantitative data were gathered from the electronic medical records detailing quarterly HIV rapid test rates in the ED setting spanning the first 5 years. Comprehensive cost analyses were conducted to evaluate the financial impact of this implementation. At 5 years, a total of 2,620 tests were conducted with a quarterly mean of 131 ± 81. Despite quarterly variability in testing rates, regression analysis revealed an average increase of 3.58 tests per quarter. Over the course of this implementation, Veterans Health Administration policy transitioned from written to verbal consent for HIV testing, serving to reduce the time and cost(s) associated with the testing process. Our data indicated salient health outcome benefits for patients with respect to the potential for earlier detection, and associated long-run cost savings. Copyright © 2015. Published by Elsevier Inc.

  1. Spin-Label CW Microwave Power Saturation and Rapid Passage with Triangular Non-Adiabatic Rapid Sweep (NARS) and Adiabatic Rapid Passage (ARP) EPR Spectroscopy

    Science.gov (United States)

    Kittell, Aaron W.; Hyde, James S.

    2015-01-01

    Non-adiabatic rapid passage (NARS) electron paramagnetic resonance (EPR) spectroscopy was introduced by Kittell, A.W., Camenisch, T.G., Ratke, J.J. Sidabras, J.W., Hyde, J.S., 2011 as a general purpose technique to collect the pure absorption response. The technique has been used to improve sensitivity relative to sinusoidal magnetic field modulation, increase the range of inter-spin distances that can be measured under near physiological conditions, and enhance spectral resolution in copper (II) spectra. In the present work, the method is extended to CW microwave power saturation of spin-labeled T4 Lysozyme (T4L). As in the cited papers, rapid triangular sweep of the polarizing magnetic field was superimposed on slow sweep across the spectrum. Adiabatic rapid passage (ARP) effects were encountered in samples undergoing very slow rotational diffusion as the triangular magnetic field sweep rate was increased. The paper reports results of variation of experimental parameters at the interface of adiabatic and non-adiabatic rapid sweep conditions. Comparison of the forward (up) and reverse (down) triangular sweeps is shown to be a good indicator of the presence of rapid passage effects. Spectral turning points can be distinguished from spectral regions between turning points in two ways: differential microwave power saturation and differential passage effects. Oxygen accessibility data are shown under NARS conditions that appear similar to conventional field modulation data. However, the sensitivity is much higher, permitting, in principle, experiments at substantially lower protein concentrations. Spectral displays were obtained that appear sensitive to rotational diffusion in the range of rotational correlation times of 10−3 to 10−7 s in a manner that is analogous to saturation transfer spectroscopy. PMID:25917132

  2. CRDM motion analysis using machine learning technique

    International Nuclear Information System (INIS)

    Nishimura, Takuya; Nakayama, Hiroyuki; Saitoh, Mayumi; Yaguchi, Seiji

    2017-01-01

    Magnetic jack type Control Rod Drive Mechanism (CRDM) for pressurized water reactor (PWR) plant operates control rods in response to electrical signals from a reactor control system. CRDM operability is evaluated by quantifying armature's response of closed/opened time which means interval time between coil energizing/de-energizing points and armature closed/opened points. MHI has already developed an automatic CRDM motion analysis and applied it to actual plants so far. However, CRDM operational data has wide variation depending on their characteristics such as plant condition, plant, etc. In the existing motion analysis, there is an issue of analysis accuracy for applying a single analysis technique to all plant conditions, plants, etc. In this study, MHI investigated motion analysis using machine learning (Random Forests) which is flexibly accommodated to CRDM operational data with wide variation, and is improved analysis accuracy. (author)

  3. Technique of sample preparation for analysis of gasoline and lubricating oils by X-ray fluorescence analysis

    International Nuclear Information System (INIS)

    Avila P, P.

    1990-03-01

    The X-ray fluorescence laboratory of the National Institute of Nuclear Research when not having a technique for the analysis of oils it has intended, with this work, to develop a preparation technique for the analysis of the metals of Pb, Cr, Ni, V and Mo in gasolines and oils, by means of the spectrometry by X-ray fluorescence analysis. The obtained results, its will be of great utility for the one mentioned laboratory. (Author)

  4. Ultra-modified rapid sequence induction with transnasal humidified rapid insufflation ventilatory exchange: Challenging convention

    Directory of Open Access Journals (Sweden)

    Ketan Sakharam Kulkarni

    2018-01-01

    Full Text Available During positive pressure ventilation, gastric inflation and subsequent pulmonary aspiration can occur. Rapid sequence induction (RSI technique is an age-old formula to prevent this. We adopted a novel approach of RSI for patients with high risk of aspiration and evaluated it further in patients undergoing laparoscopic surgeries. We believe that, in patients with risk of gastric insufflation and pulmonary aspiration, transnasal humidified rapid-insufflation ventilatory exchange can be useful in facilitating pre- and apnoeic oxygenation till tracheal isolation is achieved.

  5. The design of rapid turbidity measurement system based on single photon detection techniques

    Science.gov (United States)

    Yang, Yixin; Wang, Huanqin; Cao, Yangyang; Gui, Huaqiao; Liu, Jianguo; Lu, Liang; Cao, Huibin; Yu, Tongzhu; You, Hui

    2015-10-01

    A new rapid turbidity measurement system has been developed to measure the turbidity of drinking water. To determinate the turbidity quantitatively, the total intensity of scattering light has been measured and quantified as number of photons by adopting the single photon detection techniques (SPDT) which has the advantage of high sensitivity. On the basis of SPDT, the measurement system has been built and series of experiments have been carried out. Combining then the 90° Mie scattering theory with the principle of SPDT, a turbidity measurement model has been proposed to explain the experimental results. The experimental results show that a turbidity, which is as low as 0.1 NTU (Nephelometric Turbidity Units), can be measured steadily within 100 ms. It also shows a good linearity and stability over the range of 0.1-400 NTU and the precision can be controlled within 5% full scale. In order to improve its precision and stability, some key parameters, including the sampling time and incident light intensity, have been discussed. It has been proved that, to guarantee an excellent system performance, a good compromise between the measurement speed and the low power consumption should be considered adequately depending on the practical applications.

  6. Diffusion MRI of the neonate brain: acquisition, processing and analysis techniques

    Energy Technology Data Exchange (ETDEWEB)

    Pannek, Kerstin [University of Queensland, Centre for Clinical Research, Brisbane (Australia); University of Queensland, School of Medicine, Brisbane (Australia); University of Queensland, Centre for Advanced Imaging, Brisbane (Australia); Guzzetta, Andrea [IRCCS Stella Maris, Department of Developmental Neuroscience, Calambrone Pisa (Italy); Colditz, Paul B. [University of Queensland, Centre for Clinical Research, Brisbane (Australia); University of Queensland, Perinatal Research Centre, Brisbane (Australia); Rose, Stephen E. [University of Queensland, Centre for Clinical Research, Brisbane (Australia); University of Queensland, Centre for Advanced Imaging, Brisbane (Australia); University of Queensland Centre for Clinical Research, Royal Brisbane and Women' s Hospital, Brisbane (Australia)

    2012-10-15

    Diffusion MRI (dMRI) is a popular noninvasive imaging modality for the investigation of the neonate brain. It enables the assessment of white matter integrity, and is particularly suited for studying white matter maturation in the preterm and term neonate brain. Diffusion tractography allows the delineation of white matter pathways and assessment of connectivity in vivo. In this review, we address the challenges of performing and analysing neonate dMRI. Of particular importance in dMRI analysis is adequate data preprocessing to reduce image distortions inherent to the acquisition technique, as well as artefacts caused by head movement. We present a summary of techniques that should be used in the preprocessing of neonate dMRI data, and demonstrate the effect of these important correction steps. Furthermore, we give an overview of available analysis techniques, ranging from voxel-based analysis of anisotropy metrics including tract-based spatial statistics (TBSS) to recently developed methods of statistical analysis addressing issues of resolving complex white matter architecture. We highlight the importance of resolving crossing fibres for tractography and outline several tractography-based techniques, including connectivity-based segmentation, the connectome and tractography mapping. These techniques provide powerful tools for the investigation of brain development and maturation. (orig.)

  7. Hyphenated chromatographic techniques for the rapid screening and identification of antioxidants in methanolic extracts of pharmaceutically used plants .

    NARCIS (Netherlands)

    Exarchou, V.; Fiamegos, Y.C.; Beek, van T.A.; Nanos, C.G.; Vervoort, J.J.M.

    2006-01-01

    Phytochemical analysis is an important scientific research area, which normally relies on a number of rather laborious and time-consuming techniques for compound identification. Isolation of the ingredients of plant extracts in adequate quantities for spectral and biological analysis was the basis

  8. Analysis of body fluids for forensic purposes: from laboratory testing to non-destructive rapid confirmatory identification at a crime scene.

    Science.gov (United States)

    Virkler, Kelly; Lednev, Igor K

    2009-07-01

    Body fluid traces recovered at crime scenes are among the most important types of evidence to forensic investigators. They contain valuable DNA evidence which can identify a suspect or victim as well as exonerate an innocent individual. The first step of identifying a particular body fluid is highly important since the nature of the fluid is itself very informative to the investigation, and the destructive nature of a screening test must be considered when only a small amount of material is available. The ability to characterize an unknown stain at the scene of the crime without having to wait for results from a laboratory is another very critical step in the development of forensic body fluid analysis. Driven by the importance for forensic applications, body fluid identification methods have been extensively developed in recent years. The systematic analysis of these new developments is vital for forensic investigators to be continuously educated on possible superior techniques. Significant advances in laser technology and the development of novel light detectors have dramatically improved spectroscopic methods for molecular characterization over the last decade. The application of this novel biospectroscopy for forensic purposes opens new and exciting opportunities for the development of on-field, non-destructive, confirmatory methods for body fluid identification at a crime scene. In addition, the biospectroscopy methods are universally applicable to all body fluids unlike the majority of current techniques which are valid for individual fluids only. This article analyzes the current methods being used to identify body fluid stains including blood, semen, saliva, vaginal fluid, urine, and sweat, and also focuses on new techniques that have been developed in the last 5-6 years. In addition, the potential of new biospectroscopic techniques based on Raman and fluorescence spectroscopy is evaluated for rapid, confirmatory, non-destructive identification of a body

  9. Flash Infrared Thermography Contrast Data Analysis Technique

    Science.gov (United States)

    Koshti, Ajay

    2014-01-01

    This paper provides information on an IR Contrast technique that involves extracting normalized contrast versus time evolutions from the flash thermography inspection infrared video data. The analysis calculates thermal measurement features from the contrast evolution. In addition, simulation of the contrast evolution is achieved through calibration on measured contrast evolutions from many flat-bottom holes in the subject material. The measurement features and the contrast simulation are used to evaluate flash thermography data in order to characterize delamination-like anomalies. The thermal measurement features relate to the anomaly characteristics. The contrast evolution simulation is matched to the measured contrast evolution over an anomaly to provide an assessment of the anomaly depth and width which correspond to the depth and diameter of the equivalent flat-bottom hole (EFBH) similar to that used as input to the simulation. A similar analysis, in terms of diameter and depth of an equivalent uniform gap (EUG) providing a best match with the measured contrast evolution, is also provided. An edge detection technique called the half-max is used to measure width and length of the anomaly. Results of the half-max width and the EFBH/EUG diameter are compared to evaluate the anomaly. The information provided here is geared towards explaining the IR Contrast technique. Results from a limited amount of validation data on reinforced carbon-carbon (RCC) hardware are included in this paper.

  10. Rapid Mapping and Deformation Analysis over Cultural Heritage and Rural Sites Based on Persistent Scatterer Interferometry

    Directory of Open Access Journals (Sweden)

    D. Tapete

    2012-01-01

    Full Text Available We propose an easy-to-use procedure of “PSI-based rapid mapping and deformation analysis,” to effectively exploit Persistent Scatterer Interferometry (PSI for multispatial/temporal hazard assessment of cultural heritage and rural sites, update the condition report at the scale of entire site and single building, and address the conservation strategies. Advantages and drawbacks of the methodology are critically discussed based on feasibility tests performed over Pitigliano and Bivigliano, respectively, located in Southern and Northern Tuscany, Italy, and representative of hilltop historic towns and countryside settlements chronically affected by natural hazards. We radar-interpreted ERS-1/2 (1992–2000 and ENVISAT (2003–2010 datasets, already processed, respectively with the Permanent Scatterers (PSs and Persistent Scatterers Pairs (PSPs techniques, and assigned the levels of conservation criticality for both the sites. The PSI analysis allowed the zoning of the most unstable sectors of Pitigliano and showed a good agreement with the most updated hazard assessment of the cliff. The reconstruction of past/recent deformation patterns over Bivigliano confirmed the criticality for the Church of San Romolo, supporting the hypothesis of a correlation with local landslide phenomena, as also perceived from the annual motions observed over the entire site, where several landslide bodies are mapped.

  11. [Rapid measurement of trace mercury in aqueous solutions with optical-electrical dual pulse LIBS technique].

    Science.gov (United States)

    Zhang, Qian; Xiong, Wei; Chen, Yu-Qi; Li, Run-Hua

    2011-02-01

    A wood slice was used as absorber to transfer liquid sample to solid sample in order to solve the problems existing in directly analyzing aqueous solutions with laser-induced breakdown spectroscopy (LIBS). An optical-electrical dual pulse LIBS (OEDP-LIBS) technique was first used to enhance atomic emission of mercury in laser-induced plasma. The calibration curves of mercury were obtained by typical single pulse LIBS and OEDP-LIBS techniques. The limit of detection (LOD) of mercury in these two techniques reaches 2.4 and 0.3 mg x L(-1), respectively. Under current experimental conditions, the time-integrated a tomic emission of mercury at 253.65 nm was enhanced 50 times and the LOD of mercury was improved by one order, if comparing OEDP-LIBS to single pulse LIBS. The required time for a whole analysis process is less than 5 minutes. As the atomic emission of mercury decays slowly while increasing the delay time between electrical pulse and laser pulse, increasing the electrical pulse width can further enhance the time integrated intensity of mercury emission and improve the detection sensitivity of mercury by OEDP-LIBS technique.

  12. A rapid, non-sacrificial chromosome preparation technique for ...

    African Journals Online (AJOL)

    ... centrifuges or sacrificing the specimen. In situations such as the induction of triploidy or tetraploidy, it is necessary to have a quick, reliable method of assessing the results of experimental design. The technique presented in this report provides numerous, well-spread metaphase chromosomes with a tissue handling time ...

  13. Conference on Techniques of Nuclear and Conventional Analysis and Applications

    International Nuclear Information System (INIS)

    2012-01-01

    Full text : With their wide scope, particularly in the areas of environment, geology, mining, industry and life sciences; analysis techniques are of great importance in research as fundamental and applied. The Conference on Techniques for Nuclear and Conventional Analysis and Applications (TANCA) are Registered in the national strategy of opening of the University and national research centers on their local, national and international levels. This conference aims to: Promoting nuclear and conventional analytical techniques; Contribute to the creation of synergy between the different players involved in these techniques include, Universities, Research Organizations, Regulatory Authorities, Economic Operators, NGOs and others; Inform and educate potential users of the performance of these techniques; Strengthen exchanges and links between researchers, industry and policy makers; Implement a program of inter-laboratory comparison between Moroccan one hand, and their foreign counterparts on the other; Contribute to the research training of doctoral students and postdoctoral scholars. Given the relevance and importance of the issues related to environment and impact on cultural heritage, this fourth edition of TANCA is devoted to the application of analytical techniques for conventional and nuclear Questions ied to environment and its impact on cultural heritage.

  14. Rapid Analysis of U isotopic ratios in Food Stuff samples using Fusion and ICP-MS measurement: For radiation monitoring program in the vicinity of nuclear facilities

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Jong Myoung; Park, Ji Young; Jung, Yoon Hee; Kim, Hyun Cheol; Kim, Won Young; Chung, Gun Ho; Kang, Mun Ja [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    In this study, a rapid digestion and separation method for U isotopes was developed in food stuff matrix such as cabbage and rice. As an attempt to reduce social costs and apprehension arising from the radioactivity in food, an accurate and rapid assessment of radioactivity is highly desirable. Hence, it is very important to develop a series of evaluation of rapid procedures for efficient radioactivity management in food. Contrary to the α-spectrometry method, a measurement technique using ICP-MS with an advanced sample introduction and mass counting system allows radioactivity in many samples to be measured with a short time period with a high degree of accuracy and precision. In order to satisfy the method detectable activity (MDA) for the regulation of radioactivity monitoring program the analysis of U isotopes always require the extremely large sample amount. These procedures make usually the food stuff sample to carbonize during dry ashing process. The ashed residues have been especially complicated into a liquid phase because of their carbonization. This process are very time consuming and not fully recovered target isotopes.

  15. Low energy analysis techniques for CUORE

    Energy Technology Data Exchange (ETDEWEB)

    Alduino, C.; Avignone, F.T.; Chott, N.; Creswick, R.J.; Rosenfeld, C.; Wilson, J. [University of South Carolina, Department of Physics and Astronomy, Columbia, SC (United States); Alfonso, K.; Huang, H.Z.; Sakai, M.; Schmidt, J. [University of California, Department of Physics and Astronomy, Los Angeles, CA (United States); Artusa, D.R.; Rusconi, C. [University of South Carolina, Department of Physics and Astronomy, Columbia, SC (United States); INFN-Laboratori Nazionali del Gran Sasso, L' Aquila (Italy); Azzolini, O.; Camacho, A.; Keppel, G.; Palmieri, V.; Pira, C. [INFN-Laboratori Nazionali di Legnaro, Padua (Italy); Bari, G.; Deninno, M.M. [INFN-Sezione di Bologna, Bologna (Italy); Beeman, J.W. [Lawrence Berkeley National Laboratory, Materials Science Division, Berkeley, CA (United States); Bellini, F.; Cosmelli, C.; Ferroni, F.; Piperno, G. [Sapienza Universita di Roma, Dipartimento di Fisica, Rome (Italy); INFN-Sezione di Roma, Rome (Italy); Benato, G.; Singh, V. [University of California, Department of Physics, Berkeley, CA (United States); Bersani, A.; Caminata, A. [INFN-Sezione di Genova, Genoa (Italy); Biassoni, M.; Brofferio, C.; Capelli, S.; Carniti, P.; Cassina, L.; Chiesa, D.; Clemenza, M.; Faverzani, M.; Fiorini, E.; Gironi, L.; Gotti, C.; Maino, M.; Nastasi, M.; Nucciotti, A.; Pavan, M.; Pozzi, S.; Sisti, M.; Terranova, F.; Zanotti, L. [Universita di Milano-Bicocca, Dipartimento di Fisica, Milan (Italy); INFN-Sezione di Milano Bicocca, Milan (Italy); Branca, A.; Taffarello, L. [INFN-Sezione di Padova, Padua (Italy); Bucci, C.; Cappelli, L.; D' Addabbo, A.; Gorla, P.; Pattavina, L.; Pirro, S. [INFN-Laboratori Nazionali del Gran Sasso, L' Aquila (Italy); Canonica, L. [INFN-Laboratori Nazionali del Gran Sasso, L' Aquila (Italy); Massachusetts Institute of Technology, Cambridge, MA (United States); Cao, X.G.; Fang, D.Q.; Ma, Y.G.; Wang, H.W.; Zhang, G.Q. [Shanghai Institute of Applied Physics, Chinese Academy of Sciences, Shanghai (China); Cardani, L.; Casali, N.; Dafinei, I.; Morganti, S.; Mosteiro, P.J.; Tomei, C.; Vignati, M. [INFN-Sezione di Roma, Rome (Italy); Copello, S.; Di Domizio, S.; Marini, L.; Pallavicini, M. [INFN-Sezione di Genova, Genoa (Italy); Universita di Genova, Dipartimento di Fisica, Genoa (Italy); Cremonesi, O.; Ferri, E.; Giachero, A.; Pessina, G.; Previtali, E. [INFN-Sezione di Milano Bicocca, Milan (Italy); Cushman, J.S.; Davis, C.J.; Heeger, K.M.; Lim, K.E.; Maruyama, R.H. [Yale University, Department of Physics, New Haven, CT (United States); D' Aguanno, D.; Pagliarone, C.E. [INFN-Laboratori Nazionali del Gran Sasso, L' Aquila (Italy); Universita degli Studi di Cassino e del Lazio Meridionale, Dipartimento di Ingegneria Civile e Meccanica, Cassino (Italy); Dell' Oro, S. [INFN-Laboratori Nazionali del Gran Sasso, L' Aquila (Italy); INFN-Gran Sasso Science Institute, L' Aquila (Italy); Di Vacri, M.L.; Santone, D. [INFN-Laboratori Nazionali del Gran Sasso, L' Aquila (Italy); Universita dell' Aquila, Dipartimento di Scienze Fisiche e Chimiche, L' Aquila (Italy); Drobizhev, A.; Hennings-Yeomans, R.; Kolomensky, Yu.G.; Wagaarachchi, S.L. [University of California, Department of Physics, Berkeley, CA (United States); Lawrence Berkeley National Laboratory, Nuclear Science Division, Berkeley, CA (United States); Franceschi, M.A.; Ligi, C.; Napolitano, T. [INFN-Laboratori Nazionali di Frascati, Rome (Italy); Freedman, S.J. [University of California, Department of Physics, Berkeley, CA (United States); Lawrence Berkeley National Laboratory, Nuclear Science Division, Berkeley, CA (United States); Fujikawa, B.K.; Mei, Y.; Schmidt, B.; Smith, A.R.; Welliver, B. [Lawrence Berkeley National Laboratory, Nuclear Science Division, Berkeley, CA (United States); Giuliani, A.; Novati, V. [Universite Paris-Saclay, CSNSM, Univ. Paris-Sud, CNRS/IN2P3, Orsay (France); Gladstone, L.; Leder, A.; Ouellet, J.L.; Winslow, L.A. [Massachusetts Institute of Technology, Cambridge, MA (United States); Gutierrez, T.D. [California Polytechnic State University, Physics Department, San Luis Obispo, CA (United States); Haller, E.E. [Lawrence Berkeley National Laboratory, Materials Science Division, Berkeley, CA (United States); University of California, Department of Materials Science and Engineering, Berkeley, CA (United States); Han, K. [Shanghai Jiao Tong University, Department of Physics and Astronomy, Shanghai (China); Hansen, E. [University of California, Department of Physics and Astronomy, Los Angeles, CA (United States); Massachusetts Institute of Technology, Cambridge, MA (United States); Kadel, R. [Lawrence Berkeley National Laboratory, Physics Division, Berkeley, CA (United States); Martinez, M. [Sapienza Universita di Roma, Dipartimento di Fisica, Rome (Italy); INFN-Sezione di Roma, Rome (Italy); Universidad de Zaragoza, Laboratorio de Fisica Nuclear y Astroparticulas, Saragossa (Spain); Moggi, N.; Zucchelli, S. [INFN-Sezione di Bologna, Bologna (Italy); Universita di Bologna - Alma Mater Studiorum, Dipartimento di Fisica e Astronomia, Bologna (IT); Nones, C. [CEA/Saclay, Service de Physique des Particules, Gif-sur-Yvette (FR); Norman, E.B.; Wang, B.S. [Lawrence Livermore National Laboratory, Livermore, CA (US); University of California, Department of Nuclear Engineering, Berkeley, CA (US); O' Donnell, T. [Virginia Polytechnic Institute and State University, Center for Neutrino Physics, Blacksburg, VA (US); Sangiorgio, S.; Scielzo, N.D. [Lawrence Livermore National Laboratory, Livermore, CA (US); Wise, T. [Yale University, Department of Physics, New Haven, CT (US); University of Wisconsin, Department of Physics, Madison, WI (US); Woodcraft, A. [University of Edinburgh, SUPA, Institute for Astronomy, Edinburgh (GB); Zimmermann, S. [Lawrence Berkeley National Laboratory, Engineering Division, Berkeley, CA (US)

    2017-12-15

    CUORE is a tonne-scale cryogenic detector operating at the Laboratori Nazionali del Gran Sasso (LNGS) that uses tellurium dioxide bolometers to search for neutrinoless double-beta decay of {sup 130}Te. CUORE is also suitable to search for low energy rare events such as solar axions or WIMP scattering, thanks to its ultra-low background and large target mass. However, to conduct such sensitive searches requires improving the energy threshold to 10 keV. In this paper, we describe the analysis techniques developed for the low energy analysis of CUORE-like detectors, using the data acquired from November 2013 to March 2015 by CUORE-0, a single-tower prototype designed to validate the assembly procedure and new cleaning techniques of CUORE. We explain the energy threshold optimization, continuous monitoring of the trigger efficiency, data and event selection, and energy calibration at low energies in detail. We also present the low energy background spectrum of CUORE-0 below 60 keV. Finally, we report the sensitivity of CUORE to WIMP annual modulation using the CUORE-0 energy threshold and background, as well as an estimate of the uncertainty on the nuclear quenching factor from nuclear recoils in CUORE-0. (orig.)

  16. Hlaallele Detection Using Molecular Techniques

    Directory of Open Access Journals (Sweden)

    Philip A. Dyer

    1993-01-01

    Full Text Available There are now many molecular biological techniques available to define HLA class I and class II alleles. Some of these are also applicable to other human polymorphic genes, in particular to those non-HLA genes encoded within the Mhc. The range of techniques available allows laboratories to choose those most suited to their purpose. The routine laboratory supporting solid organ transplants will need to type large numbers of potential recipients over a period of time, probably using PCR-SSOP while donors will be typed singly and rapidly using PCR-SSP with HLA allele compatibility determined by heteroduplex analysis. Laboratories supporting bone marrow transplantation, where time is less pressing, can choose from the whole range of techniques to determine accurately donor recipient Mhc compatibility. For disease studies, techniques defining precise HLA allele sequence polymorphisms are needed and high sample numbers have to be accommodated. When an association is established allele sequencing has to be used. In the near future, the precise role of HLA alleles in transplantation and disease susceptibility is likely to be established unambiguously.

  17. Analyzing suitability for urban expansion under rapid coastal urbanization with remote sensing and GIS techniques: a case study of Lianyungang, China

    Science.gov (United States)

    Zhao, Wenjun; Zhu, Xiaodong; Reenberg, Anette; Sun, Xiang

    2010-10-01

    Beginning in 2000, Lianyungang's urbanization entered a period of rapid growth, spatially as well as economically. Rapid and intensive expansion of "construction land" imposed increasing pressures on regional environment. With the support of remote sensing data and GIS tools, this paper reports a "present-capacity-potential" integrated suitability analysis framework, in order to characterize and evaluate the suitability of urban expansion in Lianyungang. We found that during the rapid coastal urbanization process from 2000 to 2008, the characteristics of physical expansion in the study area were characterized by a combination of high-density expansion and sprawling development. The land use conversion driven by urbanization and industrialization has not occurred only in city districts, but also the surrounding areas that were spatially absorbed by urban growth, while closely associated and greatly influenced by the explosive growth of industrial establishment. The over-consumption of land resources in the areas with low environmental carrying capacity, particularly in the eastern coastal area, should be strictly controlled. Compared to conventional land suitability analysis methods, the proposed integrated approach could better review the potential environmental impacts of urban expansion and provide guidance for decision makers.

  18. Rapid tryptic mapping using enzymatically active mass spectrometer probe tips

    Energy Technology Data Exchange (ETDEWEB)

    Dogruel, D.; Williams, P.; Nelson, R.W. [Arizona State Univ., Tempe, AZ (United States)

    1995-12-01

    A method has been developed for rapid, sensitive, and accurate tryptic mapping of polypeptides using matrix-assisted laser desorption/ionization time-of-flight mass analysis. The technique utilizes mass spectrometer probe tips which have been activated through the covalent immobilization of trypsin. The enzymatically active probe tips were used for the tryptic mapping of chicken egg lysozyme and the results compared with those obtained using either free trypsin or agarose-immobilized trypsin. A significant increase in the overall sensitivity of the process was observed using the active probe tips, as well as the production of more characteristic proteolytic fragments and the elimination of background signals due to the autolysis of the trypsin. Further, probe tip digestions were found to be rapid and convenient. 19 refs., 6 figs., 2 tabs.

  19. NMR and modelling techniques in structural and conformation analysis

    Energy Technology Data Exchange (ETDEWEB)

    Abraham, R J [Liverpool Univ. (United Kingdom)

    1994-12-31

    The use of Lanthanide Induced Shifts (L.I.S.) and modelling techniques in conformational analysis is presented. The use of Co{sup III} porphyrins as shift reagents is discussed, with examples of their use in the conformational analysis of some heterocyclic amines. (author) 13 refs., 9 figs.

  20. The application of value analysis techniques for complex problems

    International Nuclear Information System (INIS)

    Chiquelin, W.R.; Cossel, S.C.; De Jong, V.J.; Halverson, T.W.

    1986-01-01

    This paper discusses the application of the Value Analysis technique to the transuranic package transporter (TRUPACT). A team representing five different companies or organizations with diverse technical backgrounds was formed to analyze and recommend improvements. The results were a 38% systems-wide savings, if incorporated, and a shipping container which is volumetrically and payload efficient as well as user friendly. The Value Analysis technique is a proven tool widely used in many diverse areas both in the government and the private sector. Value Analysis uses functional diagramming of a piece of equipment or process to discretely identify every facet of the item being analyzed. A standard set of questions is then asked: What is it?, What does it do?, What does it cost?, What else will do the task?, and What would that cost? Using logic and a disciplined approach, the result of the Value Analysis performs the necessary functions at a high quality and the lowest overall cost

  1. Use of Atomic and Nuclear Techniques in Elemental and Isotopic Analysis

    International Nuclear Information System (INIS)

    2008-01-01

    This book is divided into four chapters which were presented by six authors of the best Arab specialists who have used the atomic and nuclear techniques for a long time and recognized their importance and capabilities in scientific researches. Atomic and Nuclear techniques are very successful in the field of analysis because they are the only way to proceed the analysis process with the requested accuracy and they are the cheapest at the same time. A number of these techniques were collected in this book on the basis of their accuracy and the abundance of using them in the analysis of material components, specially when these elements exist with insignificant percentage as in the case of poisons science, archaeology, nutrition, medicine and other applications.

  2. Atoms for Food and Nutrition: Application of Nuclear Techniques in Food and Agriculture

    International Nuclear Information System (INIS)

    Nyambura, M.

    2017-01-01

    Light-based soil and plant analysis for evidence-based decision making Leveraging latest technology from lab to space. Soil-Plants Spectroscopy is the Simplicity of light-Light based techniques for measurement of soil and plant materials and farmers advisory. Interaction of light with matter provides rapid, low cost & reproducible soil characterization. Soil Health Surveillance enables surveillance science and evidence-based approaches - things not previously feasible.human and laboratory capacity for diagnosing, surveying and managing soil nutrient deficiencies in Sub-Saharan Africa is woefully inadequate for the task. Strengthening Africa capacity on new science and technology a key resilience strategy for rapid and low cost analytical and diagnostic techniques, improved and well-targeted guidelines and Scientific expertise

  3. Infusing Reliability Techniques into Software Safety Analysis

    Science.gov (United States)

    Shi, Ying

    2015-01-01

    Software safety analysis for a large software intensive system is always a challenge. Software safety practitioners need to ensure that software related hazards are completely identified, controlled, and tracked. This paper discusses in detail how to incorporate the traditional reliability techniques into the entire software safety analysis process. In addition, this paper addresses how information can be effectively shared between the various practitioners involved in the software safety analyses. The author has successfully applied the approach to several aerospace applications. Examples are provided to illustrate the key steps of the proposed approach.

  4. Meta-analysis in a nutshell: Techniques and general findings

    DEFF Research Database (Denmark)

    Paldam, Martin

    2015-01-01

    The purpose of this article is to introduce the technique and main findings of meta-analysis to the reader, who is unfamiliar with the field and has the usual objections. A meta-analysis is a quantitative survey of a literature reporting estimates of the same parameter. The funnel showing...

  5. Rapid detection of pathogenic bacteria by volatile organic compound (VOC) analysis

    Science.gov (United States)

    Senecal, Andre G.; Magnone, Joshua; Yeomans, Walter; Powers, Edmund M.

    2002-02-01

    Developments in rapid detection technologies have made countless improvements over the years. However, because of the limited sample that these technologies can process in a single run, the chance of capturing and identifying a small amount of pathogens is difficult. The problem is further magnified by the natural random distribution of pathogens in foods. Methods to simplify pathogenic detection through the identification of bacteria specific VOC were studied. E. coli O157:H7 and Salmonella typhimurium were grown on selected agar medium to model protein, and carbohydrate based foods. Pathogenic and common spoilage bacteria (Pseudomonas and Morexella) were screened for unique VOC production. Bacteria were grown on agar slants in closed vials. Headspace sampling was performed at intervals up to 24 hours using Solid Phase Micro-Extraction (SPME) techniques followed by GC/MS analysis. Development of unique volatiles was followed to establish sensitivity of detection. E. coli produced VOC not found in either Trypticase Soy Yeast (TSY) agar blanks or spoilage organism samples were - indole, 1-decanol, and 2-nonanone. Salmonella specific VOC grown on TSY were 3-methyl-1-butanol, dimethyl sulfide, 2-undecanol, 2-pentadecanol and 1-octanol. Trials on potato dextrose agar (PDA) slants indicated VOC specific for E. coli and Salmonella when compared to PDA blanks and Pseudomonas samples. However, these VOC peaks were similar for both pathogens. Morexella did not grow on PDA slants. Work will continue with model growth mediums at various temperatures, and mixed flora inoculums. As well as, VOC production based on the dynamics of bacterial growth.

  6. Contributions to fuzzy polynomial techniques for stability analysis and control

    OpenAIRE

    Pitarch Pérez, José Luis

    2014-01-01

    The present thesis employs fuzzy-polynomial control techniques in order to improve the stability analysis and control of nonlinear systems. Initially, it reviews the more extended techniques in the field of Takagi-Sugeno fuzzy systems, such as the more relevant results about polynomial and fuzzy polynomial systems. The basic framework uses fuzzy polynomial models by Taylor series and sum-of-squares techniques (semidefinite programming) in order to obtain stability guarantees...

  7. Rapid screening of pharmaceutical drugs using thermal desorption – SALDI mass spectrometry

    International Nuclear Information System (INIS)

    Grechnikov, A A; Kubasov, A E; Borodkov, A S; Georgieva, V B; Nikiforov, S M; Simanovsky, Ya O; Alimpiev, S S

    2012-01-01

    A novel approach to the rapid screening of pharmaceutical drugs by surface assisted laser desorption-ionization (SALDI) mass spectrometry with the rotating ball interface coupled with temperature programmed thermal desorption has been developed. Analytes were thermally desorbed and deposited onto the surface of amorphous silicon substrate attached to the rotating ball. The ball was rotated and the deposited analytes were analyzed using SALDI. The effectiveness of coupling SALDI mass spectrometry with thermal desorption was evaluated by the direct and rapid analysis of tablets containing lidocaine, diphenhydramine and propranolol without any sample pretreatment. The overall duration of the screening procedure was 30÷40 sec. Real urine samples were studied for drug analysis. It is shown that with simple preparation steps, urine samples can be quantitatively analyzed using the proposed technique with the detection limits in the range of 0.2÷0.5 ng/ml.

  8. Analytical techniques for wine analysis: An African perspective; a review

    International Nuclear Information System (INIS)

    Villiers, André de; Alberts, Phillipus; Tredoux, Andreas G.J.; Nieuwoudt, Hélène H.

    2012-01-01

    Highlights: ► Analytical techniques developed for grape and wine analysis in Africa are reviewed. ► The utility of infrared spectroscopic methods is demonstrated. ► An overview of separation of wine constituents by GC, HPLC, CE is presented. ► Novel LC and GC sample preparation methods for LC and GC are presented. ► Emerging methods for grape and wine analysis in Africa are discussed. - Abstract: Analytical chemistry is playing an ever-increasingly important role in the global wine industry. Chemical analysis of wine is essential in ensuring product safety and conformity to regulatory laws governing the international market, as well as understanding the fundamental aspects of grape and wine production to improve manufacturing processes. Within this field, advanced instrumental analysis methods have been exploited more extensively in recent years. Important advances in instrumental analytical techniques have also found application in the wine industry. This review aims to highlight the most important developments in the field of instrumental wine and grape analysis in the African context. The focus of this overview is specifically on the application of advanced instrumental techniques, including spectroscopic and chromatographic methods. Recent developments in wine and grape analysis and their application in the African context are highlighted, and future trends are discussed in terms of their potential contribution to the industry.

  9. Analytical techniques for wine analysis: An African perspective; a review

    Energy Technology Data Exchange (ETDEWEB)

    Villiers, Andre de, E-mail: ajdevill@sun.ac.za [Department of Chemistry and Polymer Science, Stellenbosch University, Private Bag X1, Matieland 7602, Stellenbosch (South Africa); Alberts, Phillipus [Department of Chemistry and Polymer Science, Stellenbosch University, Private Bag X1, Matieland 7602, Stellenbosch (South Africa); Tredoux, Andreas G.J.; Nieuwoudt, Helene H. [Institute for Wine Biotechnology, Department of Viticulture and Oenology, Stellenbosch University, Private Bag X1, Matieland 7602, Stellenbosch (South Africa)

    2012-06-12

    Highlights: Black-Right-Pointing-Pointer Analytical techniques developed for grape and wine analysis in Africa are reviewed. Black-Right-Pointing-Pointer The utility of infrared spectroscopic methods is demonstrated. Black-Right-Pointing-Pointer An overview of separation of wine constituents by GC, HPLC, CE is presented. Black-Right-Pointing-Pointer Novel LC and GC sample preparation methods for LC and GC are presented. Black-Right-Pointing-Pointer Emerging methods for grape and wine analysis in Africa are discussed. - Abstract: Analytical chemistry is playing an ever-increasingly important role in the global wine industry. Chemical analysis of wine is essential in ensuring product safety and conformity to regulatory laws governing the international market, as well as understanding the fundamental aspects of grape and wine production to improve manufacturing processes. Within this field, advanced instrumental analysis methods have been exploited more extensively in recent years. Important advances in instrumental analytical techniques have also found application in the wine industry. This review aims to highlight the most important developments in the field of instrumental wine and grape analysis in the African context. The focus of this overview is specifically on the application of advanced instrumental techniques, including spectroscopic and chromatographic methods. Recent developments in wine and grape analysis and their application in the African context are highlighted, and future trends are discussed in terms of their potential contribution to the industry.

  10. Ratiometric analysis of fura red by flow cytometry: a technique for monitoring intracellular calcium flux in primary cell subsets.

    Directory of Open Access Journals (Sweden)

    Emily R Wendt

    Full Text Available Calcium flux is a rapid and sensitive measure of cell activation whose utility could be enhanced with better techniques for data extraction. We describe a technique to monitor calcium flux by flow cytometry, measuring Fura Red calcium dye by ratiometric analysis. This technique has several advantages: 1 using a single calcium dye provides an additional channel for surface marker characterization, 2 allows robust detection of calcium flux by minority cell populations within a heterogeneous population of primary T cells and monocytes 3 can measure total calcium flux and additionally, the proportion of responding cells, 4 can be applied to studying the effects of drug treatment, simultaneously stimulating and monitoring untreated and drug treated cells. Using chemokine receptor activation as an example, we highlight the utility of this assay, demonstrating that only cells expressing a specific chemokine receptor are activated by cognate chemokine ligand. Furthermore, we describe a technique for simultaneously stimulating and monitoring calcium flux in vehicle and drug treated cells, demonstrating the effects of the Gαi inhibitor, pertussis toxin (PTX, on chemokine stimulated calcium flux. The described real time calcium flux assay provides a robust platform for characterizing cell activation within primary cells, and offers a more accurate technique for studying the effect of drug treatment on receptor activation in a heterogeneous population of primary cells.

  11. Rapid screening for targeted genetic variants via high-resolution melting curve analysis.

    Science.gov (United States)

    Chambliss, Allison B; Resnick, Molly; Petrides, Athena K; Clarke, William A; Marzinke, Mark A

    2017-03-01

    Current methods for the detection of single nucleotide polymorphisms (SNPs) associated with aberrant drug-metabolizing enzyme function are hindered by long turnaround times and specialized techniques and instrumentation. In this study, we describe the development and validation of a high-resolution melting (HRM) curve assay for the rapid screening of variant genotypes for targeted genetic polymorphisms in the cytochrome P450 enzymes CYP2C9, CYP2C19, and CYP3A5. Sequence-specific primers were custom-designed to flank nine SNPs within the genetic regions of aforementioned drug metabolizing enzymes. PCR amplification was performed followed by amplicon denaturation by precise temperature ramping in order to distinguish genotypes by melting temperature (Tm). A standardized software algorithm was used to assign amplicons as 'reference' or 'variant' as compared to duplicate reference sequence DNA controls for each SNP. Intra-assay (n=5) precision of Tms for all SNPs was ≤0.19%, while inter-assay (n=20) precision ranged from 0.04% to 0.21%. When compared to a reference method of Sanger sequencing, the HRM assay produced no false negative results, and overcall frequency ranged from 0% to 26%, depending on the SNP. Furthermore, HRM genotyping displayed accuracy over input DNA concentrations ranging from 10 to 200 ng/μL. The presented assay provides a rapid method for the screening for genetic variants in targeted CYP450 regions with a result of 'reference' or 'variant' available within 2 h from receipt of extracted DNA. The method can serve as a screening approach to rapidly identify individuals with variant sequences who should be further investigated by reflexed confirmatory testing for aberrant cytochrome P450 enzymatic activity. Rapid knowledge of variant status may aid in the avoidance of adverse clinical events by allowing for dosing of normal metabolizer patients immediately while identifying the need to wait for confirmatory testing in those patients who are

  12. Mobile Techniques for Rapid Detection of Concealed Nuclear Material

    International Nuclear Information System (INIS)

    Rosenstock, W.; Koeble, T.; Risse, M.; Berky, W.

    2015-01-01

    To prevent the diversion of nuclear material as well as illicit production, transport and use of nuclear material we investigated in mobile techniques to detect and identify such material in the field as early as possible. For that purpose we use a highly sensitive gamma measurement system installed in a car. It consists of two large volume plastic scintillators, one on each side of the car, each scintillator with 12 l active volume, and two extreme sensitive high purity Germanium detectors with 57 cm 2 crystal diameter, cooled electrically. The measured data are processed immediately with integrated, appropriate analysis software for direct assessment including material identification and classification within seconds. The software for the plastic scintillators can differentiate between natural and artificial radioactivity, thus giving a clear hint for the existence of unexpected material. In addition, the system is equipped with highly sensitive neutron detectors. We have performed numerous measurements by passing different radioactive and nuclear sources in relatively large distances with this measurement car. Even shielded as well as masked material was detected and identified in most of the cases. We will report on the measurements performed in the field (on an exercise area) and in the lab and discuss the capabilities of the system, especially with respect to timeliness and identification. This system will improve the nuclear verification capabilities also. (author)

  13. Rapid detection of undesired cosmetic ingredients by matrix-assisted laser desorption ionization time-of-flight mass spectrometry.

    Science.gov (United States)

    Ouyang, Jie; An, Dongli; Chen, Tengteng; Lin, Zhiwei

    2017-10-01

    In recent years, cosmetic industry profits soared due to the widespread use of cosmetics, which resulted in illicit manufacturers and products of poor quality. Therefore, the rapid and accurate detection of the composition of cosmetics has become crucial. At present, numerous methods, such as gas chromatography and liquid chromatography-mass spectrometry, were available for the analysis of cosmetic ingredients. However, these methods present several limitations, such as failure to perform comprehensive and rapid analysis of the samples. Compared with other techniques, matrix-assisted laser desorption ionization time-of-flight mass spectrometry offered the advantages of wide detection range, fast speed and high accuracy. In this article, we briefly summarized how to select a suitable matrix and adjust the appropriate laser energy. We also discussed the rapid identification of undesired ingredients, focusing on antibiotics and hormones in cosmetics.

  14. In-situ Polymerization of Polyaniline/Polypyrrole Copolymer using Different Techniques

    Science.gov (United States)

    Hammad, A. S.; Noby, H.; Elkady, M. F.; El-Shazly, A. H.

    2018-01-01

    The morphology and surface area of the poly(aniline-co-pyrrole) copolymer (PANPY) are important properties which improve the efficiency of the copolymer in various applications. In this investigation, different techniques were employed to produce PANPY in different morphologies. Aniline and pyrrole were used as monomers, and ammonium peroxydisulfate (APS) was used as an oxidizer with uniform molar ratio. Rapid mixing, drop-wise mixing, and supercritical carbon dioxide (ScCO2) polymerization techniques were appointed. The chemical structure, crystallinity, porosity, and morphology of the composite were distinguished by Fourier transform infrared spectroscopy (FT-IR), X-ray diffraction (XRD), Brunauer, Emmett and Teller (BET) analysis, and transmission electron microscopy (TEM) respectively. The characterization tests indicated that the polyaniline/polypyrrole copolymer was successfully prepared with different morphologies. Based on the obtained TEM, hollow nanospheres were formed using rapid mixing technique with acetic acid that have a diameter of 75 nm and thickness 26 nm approximately. Also, according to the XRD, the produced structures have a semi- crystalline structure. The synthesized copolymer with ScCO2-assisted polymerization technique showed improved surface area (38.1 m2/g) with HCl as dopant.

  15. An operator expansion technique for path integral analysis

    International Nuclear Information System (INIS)

    Tsvetkov, I.V.

    1995-01-01

    A new method of path integral analysis in the framework of a power series technique is presented. The method is based on the operator expansion of an exponential. A regular procedure to calculate the correction terms is found. (orig.)

  16. Application of nuclear analysis techniques in ancient chinese porcelain

    International Nuclear Information System (INIS)

    Feng Songlin; Xu Qing; Feng Xiangqian; Lei Yong; Cheng Lin; Wang Yanqing

    2005-01-01

    Ancient ceramic was fired with porcelain clay. It contains various provenance information and age characteristic. It is the scientific foundation of studying Chinese porcelain to analyze and research the ancient ceramic with modern analysis methods. According to the property of nuclear analysis technique, its function and application are discussed. (authors)

  17. Application of energy dispersive x-ray techniques for water analysis

    International Nuclear Information System (INIS)

    Funtua, I. I.

    2000-07-01

    Energy dispersive x-ray fluorescence (EDXRF) is a class of emission spectroscopic techniques that depends upon the emission of characteristic x-rays following excitation of the atomic electron energy levels by tube or isotopic source x-rays. The technique has found wide range of applications that include determination of chemical elements of water and water pollutants. Three EDXRF systems, the isotopic source, secondary target and total reflection (TXRF) are available at the Centre for Energy research and Training. These systems have been applied for the analysis of sediments, suspensions, ground water, river and rainwater. The isotopic source is based on 55 Fe, 109 Cd and 241 Am excitations while the secondary target and the total reflection are utilizing a Mo x-ray tube. Sample preparation requirements for water analysis range from physical and chemical pre-concentration steps to direct analysis and elements from Al to U can be determined with these systems. The EDXRF techniques, TXRF in particular with its multielement capability, low detection limit and possibility of direct analysis for water have competitive edge over the traditional methods of atomic absorption and flame photometry

  18. The Recoverability of P-Technique Factor Analysis

    Science.gov (United States)

    Molenaar, Peter C. M.; Nesselroade, John R.

    2009-01-01

    It seems that just when we are about to lay P-technique factor analysis finally to rest as obsolete because of newer, more sophisticated multivariate time-series models using latent variables--dynamic factor models--it rears its head to inform us that an obituary may be premature. We present the results of some simulations demonstrating that even…

  19. Patient specific ankle-foot orthoses using rapid prototyping.

    Science.gov (United States)

    Mavroidis, Constantinos; Ranky, Richard G; Sivak, Mark L; Patritti, Benjamin L; DiPisa, Joseph; Caddle, Alyssa; Gilhooly, Kara; Govoni, Lauren; Sivak, Seth; Lancia, Michael; Drillio, Robert; Bonato, Paolo

    2011-01-12

    Prefabricated orthotic devices are currently designed to fit a range of patients and therefore they do not provide individualized comfort and function. Custom-fit orthoses are superior to prefabricated orthotic devices from both of the above-mentioned standpoints. However, creating a custom-fit orthosis is a laborious and time-intensive manual process performed by skilled orthotists. Besides, adjustments made to both prefabricated and custom-fit orthoses are carried out in a qualitative manner. So both comfort and function can potentially suffer considerably. A computerized technique for fabricating patient-specific orthotic devices has the potential to provide excellent comfort and allow for changes in the standard design to meet the specific needs of each patient. In this paper, 3D laser scanning is combined with rapid prototyping to create patient-specific orthoses. A novel process was engineered to utilize patient-specific surface data of the patient anatomy as a digital input, manipulate the surface data to an optimal form using Computer Aided Design (CAD) software, and then download the digital output from the CAD software to a rapid prototyping machine for fabrication. Two AFOs were rapidly prototyped to demonstrate the proposed process. Gait analysis data of a subject wearing the AFOs indicated that the rapid prototyped AFOs performed comparably to the prefabricated polypropylene design. The rapidly prototyped orthoses fabricated in this study provided good fit of the subject's anatomy compared to a prefabricated AFO while delivering comparable function (i.e. mechanical effect on the biomechanics of gait). The rapid fabrication capability is of interest because it has potential for decreasing fabrication time and cost especially when a replacement of the orthosis is required.

  20. Quantitative comparison of performance analysis techniques for modular and generic network-on-chip

    Directory of Open Access Journals (Sweden)

    M. C. Neuenhahn

    2009-05-01

    Full Text Available NoC-specific parameters feature a huge impact on performance and implementation costs of NoC. Hence, performance and cost evaluation of these parameter-dependent NoC is crucial in different design-stages but the requirements on performance analysis differ from stage to stage. In an early design-stage an analysis technique featuring reduced complexity and limited accuracy can be applied, whereas in subsequent design-stages more accurate techniques are required.

    In this work several performance analysis techniques at different levels of abstraction are presented and quantitatively compared. These techniques include a static performance analysis using timing-models, a Colored Petri Net-based approach, VHDL- and SystemC-based simulators and an FPGA-based emulator. Conducting NoC-experiments with NoC-sizes from 9 to 36 functional units and various traffic patterns, characteristics of these experiments concerning accuracy, complexity and effort are derived.

    The performance analysis techniques discussed here are quantitatively evaluated and finally assigned to the appropriate design-stages in an automated NoC-design-flow.

  1. Atomic and electronic structure transformations of silver nanoparticles under rapid cooling conditions

    OpenAIRE

    Lobato, I.; Rojas, J.; Landauro, C. V.; Torres, J.

    2008-01-01

    The structural evolution and dynamics of silver nanodrops Ag${}_{2896}$ (4.4 nm in diameter) during rapid cooling conditions has been studied by means of molecular dynamics simulations and electronic density of state calculations. The interaction of silver atoms is modeled by a tight-binding semiempirical interatomic potential proposed by Cleri and Rosato. The pair correlation functions and the pair analysis technique is applied to reveal the structural transition in the process of solidifica...

  2. Reliability analysis techniques for the design engineer

    International Nuclear Information System (INIS)

    Corran, E.R.; Witt, H.H.

    1980-01-01

    A fault tree analysis package is described that eliminates most of the housekeeping tasks involved in proceeding from the initial construction of a fault tree to the final stage of presenting a reliability analysis in a safety report. It is suitable for designers with relatively little training in reliability analysis and computer operation. Users can rapidly investigate the reliability implications of various options at the design stage, and evolve a system which meets specified reliability objectives. Later independent review is thus unlikely to reveal major shortcomings necessitating modification and projects delays. The package operates interactively allowing the user to concentrate on the creative task of developing the system fault tree, which may be modified and displayed graphically. For preliminary analysis system data can be derived automatically from a generic data bank. As the analysis procedes improved estimates of critical failure rates and test and maintenance schedules can be inserted. The computations are standard, - identification of minimal cut-sets, estimation of reliability parameters, and ranking of the effect of the individual component failure modes and system failure modes on these parameters. The user can vary the fault trees and data on-line, and print selected data for preferred systems in a form suitable for inclusion in safety reports. A case history is given - that of HIFAR containment isolation system. (author)

  3. DATA ANALYSIS TECHNIQUES IN SERVICE QUALITY LITERATURE: ESSENTIALS AND ADVANCES

    Directory of Open Access Journals (Sweden)

    Mohammed naved Khan

    2013-05-01

    Full Text Available Academic and business researchers have for long debated on the most appropriate data analysis techniques that can be employed in conducting empirical researches in the domain of services marketing. On the basis of an exhaustive review of literature, the present paper attempts to provide a concise and schematic portrayal of generally followed data analysis techniques in the field of services quality literature. Collectively, the extant literature suggests that there is a growing trend among researchers to rely on higher order multivariate techniques viz. confirmatory factor analysis, structural equation modeling etc. to generate and analyze complex models, while at times ignoring very basic and yet powerful procedures such as mean, t-Test, ANOVA and correlation. The marked shift in orientation of researchers towards using sophisticated analytical techniques can largely beattributed to the competition within the community of researchers in social sciences in general and those working in the area of service quality in particular as also growing demands of reviewers ofjournals. From a pragmatic viewpoint, it is expected that the paper will serve as a useful source of information and provide deeper insights to academic researchers, consultants, and practitionersinterested in modelling patterns of service quality and arriving at optimal solutions to increasingly complex management problems.

  4. Large-timestep techniques for particle-in-cell simulation of systems with applied fields that vary rapidly in space

    International Nuclear Information System (INIS)

    Friedman, A.; Grote, D.P.

    1996-10-01

    Under conditions which arise commonly in space-charge-dominated beam applications, the applied focusing, bending, and accelerating fields vary rapidly with axial position, while the self-fields (which are, on average, comparable in strength to the applied fields) vary smoothly. In such cases it is desirable to employ timesteps which advance the particles over distances greater than the characteristic scales over which the applied fields vary. Several related concepts are potentially applicable: sub-cycling of the particle advance relative to the field solution, a higher-order time-advance algorithm, force-averaging by integration along approximate orbits, and orbit-averaging. We report on our investigations into the utility of such techniques for systems typical of those encountered in accelerator studies for heavy-ion beam-driven inertial fusion

  5. Maximum entropy technique in the doublet structure analysis

    International Nuclear Information System (INIS)

    Belashev, B.Z.; Panebrattsev, Yu.A.; Shakhaliev, Eh.I.; Soroko, L.M.

    1998-01-01

    The Maximum Entropy Technique (MENT) for solution of the inverse problems is explained. The effective computer program for resolution of the nonlinear equations system encountered in the MENT has been developed and tested. The possibilities of the MENT have been demonstrated on the example of the MENT in the doublet structure analysis of noisy experimental data. The comparison of the MENT results with results of the Fourier algorithm technique without regularization is presented. The tolerant noise level is equal to 30% for MENT and only 0.1% for the Fourier algorithm

  6. Motor current and leakage flux signature analysis technique for condition monitoring

    International Nuclear Information System (INIS)

    Pillai, M.V.; Moorthy, R.I.K.; Mahajan, S.C.

    1994-01-01

    Till recently analysis of vibration signals was the only means available to predict the state of health of plant equipment. Motor current and leakage magnetic flux signature analysis is acquiring importance as a technique for detection of incipient damages in the electrical machines and as a supplementary technique for diagnostics of driven equipment such as centrifugal and reciprocating pumps. The state of health of the driven equipment is assessed by analysing time signal, frequency spectrum and trend analysis. For example, the pump vane frequency, piston stroke frequency, gear frequency and bearing frequencies are indicated in the current and flux spectra. By maintaining a periodic record of the amplitudes of various frequency lines in the frequency spectra, it is possible to understand the trend of deterioration of parts and components of the pump. All problems arising out of inappropriate mechanical alignment of vertical pumps are easily identified by a combined analysis of current, flux and vibration signals. It is found that current signature analysis technique is a sufficient method in itself for the analysis of state of health of reciprocating pumps and compressors. (author). 10 refs., 4 figs

  7. Nuclear analysis techniques as a component of thermoluminescence dating

    Energy Technology Data Exchange (ETDEWEB)

    Prescott, J R; Hutton, J T; Habermehl, M A [Adelaide Univ., SA (Australia); Van Moort, J [Tasmania Univ., Sandy Bay, TAS (Australia)

    1997-12-31

    In luminescence dating, an age is found by first measuring dose accumulated since the event being dated, then dividing by the annual dose rate. Analyses of minor and trace elements performed by nuclear techniques have long formed an essential component of dating. Results from some Australian sites are reported to illustrate the application of nuclear techniques of analysis in this context. In particular, a variety of methods for finding dose rates are compared, an example of a site where radioactive disequilibrium is significant and a brief summary is given of a problem which was not resolved by nuclear techniques. 5 refs., 2 tabs.

  8. Nuclear analysis techniques as a component of thermoluminescence dating

    Energy Technology Data Exchange (ETDEWEB)

    Prescott, J.R.; Hutton, J.T.; Habermehl, M.A. [Adelaide Univ., SA (Australia); Van Moort, J. [Tasmania Univ., Sandy Bay, TAS (Australia)

    1996-12-31

    In luminescence dating, an age is found by first measuring dose accumulated since the event being dated, then dividing by the annual dose rate. Analyses of minor and trace elements performed by nuclear techniques have long formed an essential component of dating. Results from some Australian sites are reported to illustrate the application of nuclear techniques of analysis in this context. In particular, a variety of methods for finding dose rates are compared, an example of a site where radioactive disequilibrium is significant and a brief summary is given of a problem which was not resolved by nuclear techniques. 5 refs., 2 tabs.

  9. Using Machine Learning Techniques in the Analysis of Oceanographic Data

    Science.gov (United States)

    Falcinelli, K. E.; Abuomar, S.

    2017-12-01

    Acoustic Doppler Current Profilers (ADCPs) are oceanographic tools capable of collecting large amounts of current profile data. Using unsupervised machine learning techniques such as principal component analysis, fuzzy c-means clustering, and self-organizing maps, patterns and trends in an ADCP dataset are found. Cluster validity algorithms such as visual assessment of cluster tendency and clustering index are used to determine the optimal number of clusters in the ADCP dataset. These techniques prove to be useful in analysis of ADCP data and demonstrate potential for future use in other oceanographic applications.

  10. The development of RFT technique for carbon steel tubes in balance-of-plant heat exchangers

    International Nuclear Information System (INIS)

    Kim, Chang Soo; Kim, Han Jong; Moon, Yong Sick; Kim, Jae Dong; Kim, Wang Bae; Nam, Min Woo

    2005-01-01

    The NDT method of carbon steel tubes is applied RFT technique. As other NDT methods, It is surprising that RFT has been rapidly developed over the past decade. These improvements have resulted in multi-frequency system, dual driver probes and development of analysis technique. Also these improvements give some profit to power plants as well as general industry. Therefore, the purpose of this study is to improve the reliability of RFT technique for carbon steel tubes. To uplift RFT technique, probes, calibration standards and specimen was developed.

  11. Rapid, all-optical crystal orientation imaging of two-dimensional transition metal dichalcogenide monolayers

    International Nuclear Information System (INIS)

    David, Sabrina N.; Zhai, Yao; Zande, Arend M. van der; O'Brien, Kevin; Huang, Pinshane Y.; Chenet, Daniel A.; Hone, James C.; Zhang, Xiang; Yin, Xiaobo

    2015-01-01

    Two-dimensional (2D) atomic materials such as graphene and transition metal dichalcogenides (TMDCs) have attracted significant research and industrial interest for their electronic, optical, mechanical, and thermal properties. While large-area crystal growth techniques such as chemical vapor deposition have been demonstrated, the presence of grain boundaries and orientation of grains arising in such growths substantially affect the physical properties of the materials. There is currently no scalable characterization method for determining these boundaries and orientations over a large sample area. We here present a second-harmonic generation based microscopy technique for rapidly mapping grain orientations and boundaries of 2D TMDCs. We experimentally demonstrate the capability to map large samples to an angular resolution of ±1° with minimal sample preparation and without involved analysis. A direct comparison of the all-optical grain orientation maps against results obtained by diffraction-filtered dark-field transmission electron microscopy plus selected-area electron diffraction on identical TMDC samples is provided. This rapid and accurate tool should enable large-area characterization of TMDC samples for expedited studies of grain boundary effects and the efficient characterization of industrial-scale production techniques

  12. Application of computer-aided three-dimensional skull model with rapid prototyping technique in repair of zygomatico-orbito-maxillary complex fracture.

    Science.gov (United States)

    Li, Wei Zhong; Zhang, Mei Chao; Li, Shao Ping; Zhang, Lei Tao; Huang, Yu

    2009-06-01

    With the advent of CAD/CAM and rapid prototyping (RP), a technical revolution in oral and maxillofacial trauma was promoted to benefit treatment, repair of maxillofacial fractures and reconstruction of maxillofacial defects. For a patient with zygomatico-facial collapse deformity resulting from a zygomatico-orbito-maxillary complex (ZOMC) fracture, CT scan data were processed by using Mimics 10.0 for three-dimensional (3D) reconstruction. The reduction design was aided by 3D virtual imaging and the 3D skull model was reproduced using the RP technique. In line with the design by Mimics, presurgery was performed on the 3D skull model and the semi-coronal incision was taken for reduction of ZOMC fracture, based on the outcome from the presurgery. Postoperative CT and images revealed significantly modified zygomatic collapse and zygomatic arch rise and well-modified facial symmetry. The CAD/CAM and RP technique is a relatively useful tool that can assist surgeons with reconstruction of the maxillofacial skeleton, especially in repairs of ZOMC fracture.

  13. Air pollution studies in Tianjing city using neutron activation analysis techniques

    International Nuclear Information System (INIS)

    Ni Bangfa; Tian Weizhi; Nie Nuiling; Wang Pingsheng

    1999-01-01

    Two sites of airborne sampling from industrial and residential areas were made in Tianjing city during February and June using PM-10 sampler and analyzed by NAA techniques; Comparison of air pollution between urban and rural area in Tianjing city was made using neutron activation analysis techniques and some other data analyzing techniques. (author)

  14. FDTD technique based crosstalk analysis of bundled SWCNT interconnects

    International Nuclear Information System (INIS)

    Duksh, Yograj Singh; Kaushik, Brajesh Kumar; Agarwal, Rajendra P.

    2015-01-01

    The equivalent electrical circuit model of a bundled single-walled carbon nanotube based distributed RLC interconnects is employed for the crosstalk analysis. The accurate time domain analysis and crosstalk effect in the VLSI interconnect has emerged as an essential design criteria. This paper presents a brief description of the numerical method based finite difference time domain (FDTD) technique that is intended for estimation of voltages and currents on coupled transmission lines. For the FDTD implementation, the stability of the proposed model is strictly restricted by the Courant condition. This method is used for the estimation of crosstalk induced propagation delay and peak voltage in lossy RLC interconnects. Both functional and dynamic crosstalk effects are analyzed in the coupled transmission line. The effect of line resistance on crosstalk induced delay, and peak voltage under dynamic and functional crosstalk is also evaluated. The FDTD analysis and the SPICE simulations are carried out at 32 nm technology node for the global interconnects. It is observed that the analytical results obtained using the FDTD technique are in good agreement with the SPICE simulation results. The crosstalk induced delay, propagation delay, and peak voltage obtained using the FDTD technique shows average errors of 4.9%, 3.4% and 0.46%, respectively, in comparison to SPICE. (paper)

  15. Development of a rapid and efficient microinjection technique for gene insertion into fertilized salmonid eggs

    Energy Technology Data Exchange (ETDEWEB)

    Chandler, D.P.; Welt, M.; Leung, F.C.

    1990-10-01

    An efficient one-step injection technique for gene insertion into fertilized rainbow trout (Oncorhynchus mykiss) eggs is described, and basic parameters affecting egg survival are reported. Freshly fertilized rainbow trout eggs were injected in the perivitelline space with a recombinant mouse metallothionein-genomic bovine growth hormone (bGH) DNA construct using a 30-gauge hypodermic needle and a standard microinjection system. Relative to control, site of injection and DNA concentration did not affect the egg survival, but injections later than 3--4 hours post fertilization were detrimental. The injection technique permitted treatment of 100 eggs/hr with survivals up to 100%, resulting in a 4% DNA uptake rate as indicated by DNA dot blot analysis. Positive dot blot results also indicated that the injected DNA is able to cross the vitelline membrane and persist for 50--60 days post hatching, obviating the need for direct injection into the germinal disk. Results are consistent with previous transgenic fish work, underscoring the usefulness of the technique for generating transgenic trout and salmonids. 24 refs., 6 figs., 3 tabs.

  16. Colour and shape analysis techniques for weed detection in cereal fields

    DEFF Research Database (Denmark)

    Pérez, A.J; López, F; Benlloch, J.V.

    2000-01-01

    . The proposed methods use colour information to discriminate between vegetation and background, whilst shape analysis techniques are applied to distinguish between crop and weeds. The determination of crop row position helps to reduce the number of objects to which shape analysis techniques are applied....... The performance of algorithms was assessed by comparing the results with a human classification, providing an acceptable success rate. The study has shown that despite the difficulties in accurately determining the number of seedlings (as in visual surveys), it is feasible to use image processing techniques......Information on weed distribution within the field is necessary to implement spatially variable herbicide application. This paper deals with the development of near-ground image capture and processing techniques in order to detect broad-leaved weeds in cereal crops under actual field conditions...

  17. A method for rapid similarity analysis of RNA secondary structures

    Directory of Open Access Journals (Sweden)

    Liu Na

    2006-11-01

    Full Text Available Abstract Background Owing to the rapid expansion of RNA structure databases in recent years, efficient methods for structure comparison are in demand for function prediction and evolutionary analysis. Usually, the similarity of RNA secondary structures is evaluated based on tree models and dynamic programming algorithms. We present here a new method for the similarity analysis of RNA secondary structures. Results Three sets of real data have been used as input for the example applications. Set I includes the structures from 5S rRNAs. Set II includes the secondary structures from RNase P and RNase MRP. Set III includes the structures from 16S rRNAs. Reasonable phylogenetic trees are derived for these three sets of data by using our method. Moreover, our program runs faster as compared to some existing ones. Conclusion The famous Lempel-Ziv algorithm can efficiently extract the information on repeated patterns encoded in RNA secondary structures and makes our method an alternative to analyze the similarity of RNA secondary structures. This method will also be useful to researchers who are interested in evolutionary analysis.

  18. A novel method for perceptual assessment of small room acoustics using rapid sensory analysis

    DEFF Research Database (Denmark)

    Kaplanis, Neofytos; Bech, Søren; Lokki, Tapio

    2016-01-01

    presented with auralized sound over a loudspeaker array and followed a rapid sensory analysis protocol. The elicited attributes and ratings are analyzed and possible links to the acoustical properties of these spaces are discussed. [This study is a part of Marie Curie Network on Dereverberation...

  19. Prompt gamma neutron activation analysis

    International Nuclear Information System (INIS)

    Goswami, A.

    2003-01-01

    Prompt gamma neutron activation analysis (PGNAA) is a technique for the analysis of elements present in solid, liquid and gaseous samples by measuring the capture gamma rays emitted from the sample during neutron irradiation. The technique is complementary to conventional neutron activation analysis (NAA) as it can be used in number of cases where NAA fails. Though the technique was first used in sixties, the advantage of the technique was first highlighted by Lindstrom and Anderson. PGNAA is increasingly being used as a rapid, instrumental, nondestructive and multielement analysis technique. A monograph and several excellent reviews on this topic have appeared recently. In this review, an attempt has been made to bring out the essential aspects of the technique, experimental arrangement and instrumentation involved, and areas of application. Some of the results will also be presented

  20. Fourier Transform Infrared Spectroscopy (FT-IR) and Simple Algorithm Analysis for Rapid and Non-Destructive Assessment of Developmental Cotton Fibers.

    Science.gov (United States)

    Liu, Yongliang; Kim, Hee-Jin

    2017-06-22

    With cotton fiber growth or maturation, cellulose content in cotton fibers markedly increases. Traditional chemical methods have been developed to determine cellulose content, but it is time-consuming and labor-intensive, mostly owing to the slow hydrolysis process of fiber cellulose components. As one approach, the attenuated total reflection Fourier transform infrared (ATR FT-IR) spectroscopy technique has also been utilized to monitor cotton cellulose formation, by implementing various spectral interpretation strategies of both multivariate principal component analysis (PCA) and 1-, 2- or 3-band/-variable intensity or intensity ratios. The main objective of this study was to compare the correlations between cellulose content determined by chemical analysis and ATR FT-IR spectral indices acquired by the reported procedures, among developmental Texas Marker-1 (TM-1) and immature fiber ( im ) mutant cotton fibers. It was observed that the R value, CI IR , and the integrated intensity of the 895 cm -1 band exhibited strong and linear relationships with cellulose content. The results have demonstrated the suitability and utility of ATR FT-IR spectroscopy, combined with a simple algorithm analysis, in assessing cotton fiber cellulose content, maturity, and crystallinity in a manner which is rapid, routine, and non-destructive.

  1. Environmental science applications with Rapid Integrated Mapping and analysis System (RIMS)

    Science.gov (United States)

    Shiklomanov, A.; Prusevich, A.; Gordov, E.; Okladnikov, I.; Titov, A.

    2016-11-01

    The Rapid Integrated Mapping and analysis System (RIMS) has been developed at the University of New Hampshire as an online instrument for multidisciplinary data visualization, analysis and manipulation with a focus on hydrological applications. Recently it was enriched with data and tools to allow more sophisticated analysis of interdisciplinary data. Three different examples of specific scientific applications with RIMS are demonstrated and discussed. Analysis of historical changes in major components of the Eurasian pan-Arctic water budget is based on historical discharge data, gridded observational meteorological fields, and remote sensing data for sea ice area. Express analysis of the extremely hot and dry summer of 2010 across European Russia is performed using a combination of near-real time and historical data to evaluate the intensity and spatial distribution of this event and its socioeconomic impacts. Integrative analysis of hydrological, water management, and population data for Central Asia over the last 30 years provides an assessment of regional water security due to changes in climate, water use and demography. The presented case studies demonstrate the capabilities of RIMS as a powerful instrument for hydrological and coupled human-natural systems research.

  2. A rapid screening procedure for the analysis of proliferation compounds in complex matrices using solid phase microextraction (SPME) and SPME with in-situ derivatization

    International Nuclear Information System (INIS)

    Alcaraz, A.; Hulsey, S.S.; Andresen, B.D.

    1995-01-01

    A variety of methods have been established using advanced chromatographic techniques and new detection systems for the analysis of chemical signatures associated with nuclear and chemical weapon (CW) proliferation. Most of these analytical methods are used in the laboratory and seldom applied in the field. The Chemical Weapons Convention (an international treaty to ban chemical weapons) may require the rapid on-site analysis of environmental samples which contain CW agents, their precursors, and/or their degradation products. In addition to the fact that certain countries are involved in CW non-compliance, there is a current uncertainty regarding nuclear proliferation. This also creates new demands on sample work-up and analytical instrumentation use in the field. The isolation and identification of unique chemical signatures in complex samples such as soils, waste tanks, and decontamination solutions would determine non-compliance. However, a primary area of detection research continues to be sample preparation. Most of the established sample cleanup technologies involve liquid/liquid, Soxhlet, or most recently, solid phase extraction (SPE). Despite the success of these traditional sample preparation techniques, they are time consuming and require multi-step procedures (especially when preparing samples for gas chromatographic mass-spectrometric analysis). The goal of this work is to demonstrate the advantages of utilizing SPME and SPME in-situ derivatization techniques to eliminate time consuming steps necessary to prepare a sample for on-site GC-MS. The authors' approach was to compare two SPME fibers and to develop methods to facilitate the isolation of polar and moderately polar proliferation compounds from complex environmental samples. This work will help to evaluate current SPME technologies for use during on-site environmental monitoring analysis

  3. Techniques for Investigating Molecular Toxicology of Nanomaterials.

    Science.gov (United States)

    Wang, Yanli; Li, Chenchen; Yao, Chenjie; Ding, Lin; Lei, Zhendong; Wu, Minghong

    2016-06-01

    Nanotechnology has been a rapidly developing field in the past few decades, resulting in the more and more exposure of nanomaterials to human. The increased applications of nanomaterials for industrial, commercial and life purposes, such as fillers, catalysts, semiconductors, paints, cosmetic additives and drug carriers, have caused both obvious and potential impacts on human health and environment. Nanotoxicology is used to study the safety of nanomaterials and has grown at the historic moment. Molecular toxicology is a new subdiscipline to study the interactions and impacts of materials at the molecular level. To better understand the relationship between the molecular toxicology and nanomaterials, this review summarizes the typical techniques and methods in molecular toxicology which are applied when investigating the toxicology of nanomaterials and include six categories: namely; genetic mutation detection, gene expression analysis, DNA damage detection, chromosomal aberration analysis, proteomics, and metabolomics. Each category involves several experimental techniques and methods.

  4. Rapid Radiochemical Analyses in Support of Fukushima Nuclear Accident - 13196

    Energy Technology Data Exchange (ETDEWEB)

    Maxwell, Sherrod L.; Culligan, Brian K.; Hutchison, Jay B. [Savannah River National Laboratory, Building 735-B, Aiken, SC 29808 (United States)

    2013-07-01

    There is an increasing need to develop faster analytical methods for emergency response, including emergency soil and air filter samples [1, 2]. The Savannah River National Laboratory (SRNL) performed analyses on samples received from Japan in April, 2011 as part of a U.S. Department of Energy effort to provide assistance to the government of Japan, following the nuclear event at Fukushima Daiichi, resulting from the earthquake and tsunami on March 11, 2011. Of particular concern was whether it was safe to plant rice in certain areas (prefectures) near Fukushima. The primary objectives of the sample collection, sample analysis, and data assessment teams were to evaluate personnel exposure hazards, identify the nuclear power plant radiological source term and plume deposition, and assist the government of Japan in assessing any environmental and agricultural impacts associated with the nuclear event. SRNL analyzed approximately 250 samples and reported approximately 500 analytical method determinations. Samples included soil from farmland surrounding the Fukushima reactors and air monitoring samples of national interest, including those collected at the U.S. Embassy and American military bases. Samples were analyzed for a wide range of radionuclides, including strontium-89, strontium-90, gamma-emitting radionuclides, and plutonium, uranium, americium and curium isotopes. Technical aspects of the rapid soil and air filter analyses will be described. The extent of radiostrontium contamination was a significant concern. For {sup 89,90}Sr analyses on soil samples, a rapid fusion technique using 1.5 gram soil aliquots to enable a Minimum Detectable Activity (MDA) of <1 pCi {sup 89,90}Sr /g of soil was employed. This sequential technique has been published recently by this laboratory for actinides and radiostrontium in soil and vegetation [3, 4]. It consists of a rapid sodium hydroxide fusion, pre-concentration steps using iron hydroxide and calcium fluoride

  5. Quality-assurance techniques used with automated analysis of gamma-ray spectra

    International Nuclear Information System (INIS)

    Killian, E.W.; Koeppen, L.D.; Femec, D.A.

    1994-01-01

    In the course of developing gamma-ray spectrum analysis algorithms for use by the Radiation Measurements Laboratory at the Idaho National Engineering Laboratory (INEL), several techniques have been developed that enhance and verify the quality of the analytical results. The use of these quality-assurance techniques is critical when gamma-ray analysis results from low-level environmental samples are used in risk assessment or site restoration and cleanup decisions. This paper describes four of the quality-assurance techniques that are in routine use at the laboratory. They are used for all types of samples, from reactor effluents to environmental samples. The techniques include: (1) the use of precision pulsers (with subsequent removal) to validate the correct operation of the spectrometer electronics for each and every spectrum acquired, (2) the use of naturally occurring and cosmically induced radionuclides in samples to help verify that the data acquisition and analysis were performed properly, (3) the use of an ambient background correction technique that involves superimposing (open-quotes mappingclose quotes) sample photopeak fitting parameters onto multiple background spectra for accurate and more consistent quantification of the background activities, (4) the use of interactive, computer-driven graphics to review the automated locating and fitting of photopeaks and to allow for manual fitting of photopeaks

  6. Study of electroless nickel plating on PerFactoryTM rapid prototype model

    OpenAIRE

    J.C. Rajaguru; C. Au, M. Duke

    2012-01-01

    This paper presents an investigation of electroless nickel plating on PerFactoryTM rapid prototype model built on PerFactoryTM R05 material. PerFactoryTM R05 is acrylic based photo sensitive resin. It is a popular material in rapid prototyping using PerFactoryTM method which employs addictive manufacturing technique to build prototypes for visual inspection, assembly etc. Metallization of such a prototype can extend the application envelop of the rapid prototyping technique as they can be use...

  7. A rapid method for estimation of Pu-isotopes in urine samples using high volume centrifuge.

    Science.gov (United States)

    Kumar, Ranjeet; Rao, D D; Dubla, Rupali; Yadav, J R

    2017-07-01

    The conventional radio-analytical technique used for estimation of Pu-isotopes in urine samples involves anion exchange/TEVA column separation followed by alpha spectrometry. This sequence of analysis consumes nearly 3-4 days for completion. Many a times excreta analysis results are required urgently, particularly under repeat and incidental/emergency situations. Therefore, there is need to reduce the analysis time for the estimation of Pu-isotopes in bioassay samples. This paper gives the details of standardization of a rapid method for estimation of Pu-isotopes in urine samples using multi-purpose centrifuge, TEVA resin followed by alpha spectrometry. The rapid method involves oxidation of urine samples, co-precipitation of plutonium along with calcium phosphate followed by sample preparation using high volume centrifuge and separation of Pu using TEVA resin. Pu-fraction was electrodeposited and activity estimated using 236 Pu tracer recovery by alpha spectrometry. Ten routine urine samples of radiation workers were analyzed and consistent radiochemical tracer recovery was obtained in the range 47-88% with a mean and standard deviation of 64.4% and 11.3% respectively. With this newly standardized technique, the whole analytical procedure is completed within 9h (one working day hour). Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. [Electromyography Analysis of Rapid Eye Movement Sleep Behavior Disorder].

    Science.gov (United States)

    Nakano, Natsuko; Kinoshita, Fumiya; Takada, Hiroki; Nakayama, Meiho

    2018-01-01

    Polysomnography (PSG), which records physiological phenomena including brain waves, breathing status, and muscle tonus, is useful for the diagnosis of sleep disorders as a gold standard. However, measurement and analysis are complex for several specific sleep disorders, such as rapid eye movement (REM) sleep behavior disorder (RBD). Usually, brain waves during REM sleep indicate an awakening pattern under relaxed conditions of skeletal and antigravity muscles. However, these muscles are activated during REM sleep when patients suffer from RBD. These activated muscle movements during REM, so-called REM without atonia (RWA) recorded by PSG, may be related to a neurodegenerative disease such as Parkinson's disease. Thus, careful analysis of RWA is significant not only physically, but also clinically. Commonly, manual viewing measurement analysis of RWA is time-consuming. Therefore, quantitative studies on RWA are rarely reported. A software program, developed from Microsoft Office Excel ® , was used to semiautomatically analyze the RWA ratio extracted from PSG to compare with manual viewing measurement analysis. In addition, a quantitative muscle tonus study was carried out to evaluate the effect of medication on RBD patients. Using this new software program, we were able to analyze RWA on the same cases in approximately 15 min as compared with 60 min in the manual viewing measurement analysis. This software program can not only quantify RWA easily but also identify RWA waves for either phasic or tonic bursts. We consider that this software program will support physicians and scientists in their future research on RBD. We are planning to offer this software program for free to physicians and scientists.

  9. Rapid detection of defects in fuel-cell electrodes using infrared reactive-flow-through technique

    Science.gov (United States)

    Das, Prodip K.; Weber, Adam Z.; Bender, Guido; Manak, Austin; Bittinat, Daniel; Herring, Andrew M.; Ulsh, Michael

    2014-09-01

    As fuel cells become more prominent, new manufacturing and production methods will need to be developed to deal efficiently and effectively with increased demand. One necessary component of this industrial growth is the accurate measurement of the variability in the manufacturing process. In this study, we present a diagnostic system that combines infrared thermography with a reactive-flow-through technique to detect catalyst-loading defects in fuel-cell gas-diffusion electrodes accurately with high spatial and temporal resolutions. Experimental results are compared with model predictions of thermal response with good agreement. Data analysis, operating-condition impacts, and detection limits are explored using both experiments and simulation. Overall, the results demonstrate the potential of this technique to measure defects on the millimeter length scale with temporal resolutions appropriate for use on a web-line. Thus we present the first development stage of a next-generation non-destructive diagnostic tool, which may be amenable to eventual use on roll-to-roll manufacturing lines.

  10. Analysis of rocks involving the x-ray diffraction, infrared and thermal gravimetric techniques

    International Nuclear Information System (INIS)

    Ikram, M.; Rauf, M.A.; Munir, N.

    1998-01-01

    Chemical analysis of rocks and minerals are usually obtained by a number of analytical techniques. The purpose of present work is to investigate the chemical composition of the rock samples and also to find that how far the results obtained by different instrumental methods are closely related. Chemical tests wee performed before using the instrumental techniques in order to determined the nature of these rocks. The chemical analysis indicated mainly the presence of carbonate and hence the carbonate nature of these rocks. The x-ray diffraction, infrared spectroscopy and thermal gravimetric analysis techniques were used for the determination of chemical composition of these samples. The results obtained by using these techniques have shown a great deal of similarities. (author)

  11. Uncertainty analysis techniques

    International Nuclear Information System (INIS)

    Marivoet, J.; Saltelli, A.; Cadelli, N.

    1987-01-01

    The origin of the uncertainty affecting Performance Assessments, as well as their propagation to dose and risk results is discussed. The analysis is focused essentially on the uncertainties introduced by the input parameters, the values of which may range over some orders of magnitude and may be given as probability distribution function. The paper briefly reviews the existing sampling techniques used for Monte Carlo simulations and the methods for characterizing the output curves, determining their convergence and confidence limits. Annual doses, expectation values of the doses and risks are computed for a particular case of a possible repository in clay, in order to illustrate the significance of such output characteristics as the mean, the logarithmic mean and the median as well as their ratios. The report concludes that provisionally, due to its better robustness, such estimation as the 90th percentile may be substituted to the arithmetic mean for comparison of the estimated doses with acceptance criteria. In any case, the results obtained through Uncertainty Analyses must be interpreted with caution as long as input data distribution functions are not derived from experiments reasonably reproducing the situation in a well characterized repository and site

  12. SWOT ANALYSIS-MANAGEMENT TECHNIQUES TO STREAMLINE PUBLIC BUSINESS MANAGEMENT

    OpenAIRE

    Rodica IVORSCHI

    2012-01-01

    SWOT analysis is the most important management techniques for understanding the strategic position of an organization. Objective SWOT analysis is to recommend strategies to ensure the best alignment between internal and external environment, and choosing the right strategy can be benefi cial organization in order to adapt their strengths to opportunities, minimize risks and eliminate weaknesses.

  13. SWOT ANALYSIS-MANAGEMENT TECHNIQUES TO STREAMLINE PUBLIC BUSINESS MANAGEMENT

    Directory of Open Access Journals (Sweden)

    Rodica IVORSCHI

    2012-06-01

    Full Text Available SWOT analysis is the most important management techniques for understanding the strategic position of an organization.Objective SWOT analysis is to recommend strategies to ensure the best alignment between internal and external environment, and choosing the right strategy can be beneficial organization in order to adapt their strengths to opportunities, minimize risks and eliminate weaknesses.

  14. Review of procedures involving separation and preconcentration for the determination of cadmium using spectrometric techniques

    International Nuclear Information System (INIS)

    Ferreira, Sergio L.C.; Andrade, Jailson B. de; Korn, Maria das Gracas A.; Pereira, Madson de G.; Lemos, Valfredo A.; Santos, Walter N.L. dos; Rodrigues, Frederico de Medeiros; Souza, Anderson S.; Ferreira, Hadla S.; Silva, Erik G.P. da

    2007-01-01

    Spectrometric techniques for the analysis of trace cadmium have developed rapidly due to the increasing need for accurate measurements at extremely low levels of this element in diverse matrices. This review covers separation and preconcentration procedures, such as electrochemical deposition, precipitation, coprecipitation, solid phase extraction, liquid-liquid extraction (LLE) and cloud point extraction (CPE), and consider the features of the their application with several spectrometric techniques

  15. Rapid characterisation of Klebsiella oxytoca isolates from contaminated liquid hand soap using mass spectrometry, FTIR and Raman spectroscopy.

    Science.gov (United States)

    Dieckmann, Ralf; Hammerl, Jens Andre; Hahmann, Hartmut; Wicke, Amal; Kleta, Sylvia; Dabrowski, Piotr Wojciech; Nitsche, Andreas; Stämmler, Maren; Al Dahouk, Sascha; Lasch, Peter

    2016-06-23

    Microbiological monitoring of consumer products and the efficiency of early warning systems and outbreak investigations depend on the rapid identification and strain characterisation of pathogens posing risks to the health and safety of consumers. This study evaluates the potential of three rapid analytical techniques for identification and subtyping of bacterial isolates obtained from a liquid hand soap product, which has been recalled and reported through the EU RAPEX system due to its severe bacterial contamination. Ten isolates recovered from two bottles of the product were identified as Klebsiella oxytoca and subtyped using matrix-assisted laser desorption/ionisation time-of-flight mass spectrometry (MALDI TOF MS), near-infrared Fourier transform (NIR FT) Raman spectroscopy and Fourier transform infrared (FTIR) spectroscopy. Comparison of the classification results obtained by these phenotype-based techniques with outcomes of the DNA-based methods pulsed-field gel electrophoresis (PFGE), multi-locus sequence typing (MLST) and single nucleotide polymorphism (SNP) analysis of whole-genome sequencing (WGS) data revealed a high level of concordance. In conclusion, a set of analytical techniques might be useful for rapid, reliable and cost-effective microbial typing to ensure safe consumer products and allow source tracking.

  16. Rapid, portable and cost-effective yeast cell viability and concentration analysis using lensfree on-chip microscopy and machine learning

    KAUST Repository

    Feizi, Alborz; Zhang, Yibo; Greenbaum, Alon; Guziak, Alex; Luong, Michelle; Chan, Raymond Yan Lok; Berg, Brandon; Ozkan, Haydar; Luo, Wei; Wu, Michael; Wu, Yichen; Ozcan, Aydogan

    2016-01-01

    and cost-effective automatic yeast analysis platform (AYAP), which can rapidly measure cell concentration and viability. AYAP is based on digital in-line holography and on-chip microscopy and rapidly images a large field-of-view of 22.5 mm2. This lens

  17. Compartmental analysis of roots in intact rapidly-growing Spergularia marina and Lactuca sativa: partial characterization of the symplasms functional in the radial transport of Na+ and K+

    International Nuclear Information System (INIS)

    Lazof, D.B.

    1987-01-01

    Techniques of compartmental analysis were adapted to the study of intact roots of rapidly-growing Spergularia marine and Lactuca sativa. Using large numbers of plants short time-courses of uptake and chase, 42 K + and 22 Na + transport could be resolved, even during a chase following a brief 10 minute labeling period. The use of intact plant systems allowed distinction of that portion of the isotope flux into the root, associated with the ion-conducting symplasms. A small compartment, which rapidly (t/sub .5/ + , accounting for the observed obtention of linear translocation rates within minutes of transferring to labeled solution. The ion contents of this compartment varied in proportion to the external ion concentration. When K + was at a high external concentration, labeled K + exchanged into this same symplasm, but chasing a short pulse indicated that K + transport to the xylem was not through a rapidly-exchanging compartment. At physiological concentrations of K + the evidence indicated that transport of K + across the root proceeded through a compartment which was not exchanging rapidly with the external medium. The rise to a linear rate of isotope translocation was gradual and translocation during a chase, following a brief pulse,was prolonged, indicating that this compartment retained its specific activity for a considerable period

  18. A BWR 24-month cycle analysis using multicycle techniques

    International Nuclear Information System (INIS)

    Hartley, K.D.

    1993-01-01

    Boiling water reactor (BWR) fuel cycle design analyses have become increasingly challenging in the past several years. As utilities continue to seek improved capacity factors, reduced power generation costs, and reduced outage costs, longer cycle lengths and fuel design optimization become important considerations. Accurate multicycle analysis techniques are necessary to determine the viability of fuel designs and cycle operating strategies to meet reactor operating requirements, e.g., meet thermal and reactivity margin constraints, while minimizing overall fuel cycle costs. Siemens Power Corporation (SPC), Nuclear Division, has successfully employed multi-cycle analysis techniques with realistic rodded cycle depletions to demonstrate equilibrium fuel cycle performance in 24-month cycles. Analyses have been performed by a BWR/5 reactor, at both rated and uprated power conditions

  19. Techniques and environments for big data analysis parallel, cloud, and grid computing

    CERN Document Server

    Dehuri, Satchidananda; Kim, Euiwhan; Wang, Gi-Name

    2016-01-01

    This volume is aiming at a wide range of readers and researchers in the area of Big Data by presenting the recent advances in the fields of Big Data Analysis, as well as the techniques and tools used to analyze it. The book includes 10 distinct chapters providing a concise introduction to Big Data Analysis and recent Techniques and Environments for Big Data Analysis. It gives insight into how the expensive fitness evaluation of evolutionary learning can play a vital role in big data analysis by adopting Parallel, Grid, and Cloud computing environments.

  20. A rapid method for the separation and estimation of uranium in geological materials using ion chromatography

    International Nuclear Information System (INIS)

    Prakash, Satya; Bangroo, P.N.

    2013-01-01

    Ion Chromatography is an elegant analytical technique which was primarily developed for the analysis of anionic species and over the years it has been used successfully to analyse various elements in different matrices. In this work the potential of Ion Chromatography has been used for the rapid separation and estimation of uranium in hydrogeochemical and other geological materials

  1. Comparative Performance Analysis of Machine Learning Techniques for Software Bug Detection

    OpenAIRE

    Saiqa Aleem; Luiz Fernando Capretz; Faheem Ahmed

    2015-01-01

    Machine learning techniques can be used to analyse data from different perspectives and enable developers to retrieve useful information. Machine learning techniques are proven to be useful in terms of software bug prediction. In this paper, a comparative performance analysis of different machine learning techniques is explored f or software bug prediction on public available data sets. Results showed most of the mac ...

  2. A rapid technique for estimating the depth and width of a two-dimensional plate from self-potential data

    International Nuclear Information System (INIS)

    Mehanee, Salah; Smith, Paul D; Essa, Khalid S

    2011-01-01

    Rapid techniques for self-potential (SP) data interpretation are of prime importance in engineering and exploration geophysics. Parameters (e.g. depth, width) estimation of the ore bodies has also been of paramount concern in mineral prospecting. In many cases, it is useful to assume that the SP anomaly is due to an ore body of simple geometric shape and to use the data to determine its parameters. In light of this, we describe a rapid approach to determine the depth and horizontal width of a two-dimensional plate from the SP anomaly. The rationale behind the scheme proposed in this paper is that, unlike the two- (2D) and three-dimensional (3D) SP rigorous source current inversions, it does not demand a priori information about the subsurface resistivity distribution nor high computational resources. We apply the second-order moving average operator on the SP anomaly to remove the unwanted (regional) effect, represented by up to a third-order polynomial, using filters of successive window lengths. By defining a function F at a fixed window length (s) in terms of the filtered anomaly computed at two points symmetrically distributed about the origin point of the causative body, the depth (z) corresponding to each half-width (w) is estimated by solving a nonlinear equation in the form ξ(s, w, z) = 0. The estimated depths are then plotted against their corresponding half-widths on a graph representing a continuous curve for this window length. This procedure is then repeated for each available window length. The depth and half-width solution of the buried structure is read at the common intersection of these various curves. The improvement of this method over the published first-order moving average technique for SP data is demonstrated on a synthetic data set. It is then verified on noisy synthetic data, complicated structures and successfully applied to three field examples for mineral exploration and we have found that the estimated depth is in good agreement with

  3. A mass spectrometer for the rapid analysis of gaseous mixtures; Spectrometre de masse pour l'analyse rapide des melanges gazeux

    Energy Technology Data Exchange (ETDEWEB)

    Cassignol, C; Ortel, Y; Taieb, J

    1950-07-01

    A mass spectrometer for leak detection and rapid gas analysis were constructed, having the characteristics and several structural features of a simple instrument described by Siry in Rev. Sri. Instruments. 540 (1947). Although exhibiting a good resolving power, the apparatus, which has no ion lenses and whose electrodes can be regulated during the performance, has not been sufficiently tested. Since several design defects have been discovered, it will probably be rebuilt with various improvements (ion source outside the magnetic field, modified circuits, etc.). (author)

  4. SHOT PUT O’BRIAN TECHNIQUE, EXTENDING THE ANALYSIS OF TECHNIQUE FROM FOUR TO SIX PHASES WITH THE DESCRIPTION

    Directory of Open Access Journals (Sweden)

    Zlatan Saračević

    2011-09-01

    Full Text Available Due to the complexity of the motion, shot put technique is described in phases for easier analysis, easer learning of technique and error correction. It is complete so that in its implementation the transition from phase to phase is not noticed. In aforementioned and described phases of O'Brian spinal shot put technique a large distance, emptiness and disconnection appear between the initial position phase and a phase of overtaking the device, which in the training methods and training technique in primary and secondary education, as well as for students and athletes beginners in shot put represents a major problem regarding connecting, training and technique advancement. Therefore, this work is aimed at facilitating the methods of training of shot put technique, extending from four to six phases, which have been described and include the complete O'Brian technique.

  5. Rapid screening assay for calcium bioavailability studies

    International Nuclear Information System (INIS)

    Luhrsen, K.R.; Hudepohl, G.R.; Smith, K.T.

    1986-01-01

    Calcium bioavailability has been studied by numerous techniques. The authors report here the use of the gamma emitting isotope of calcium ( 47 Ca) in a whole body retention assay system. In this system, calcium sources are administered by oral gavage and subsequent counts are determined and corrected for isotopic decay. Unlike iron and zinc retention curves, which exhibit a 2-3 day equilibration period, calcium reaches equilibration after 24 hours. Autoradiographic analysis of the femurs indicate that the newly absorbed calcium is rapidly distributed to the skeletal system. Moreover, the isotope is distributed along the entire bone. Comparisons of calcium bioavailability were made using intrinsic/extrinsic labeled milk from two species i.e. rat and goat as well as CaCO 3 . In addition, extrinsic labeled cow milk was examined. In the rat, the extrinsic labeled calcium from milk was better absorbed than the intrinsic calcium. This was not the case in goat milk or the calcium carbonate which exhibited no significant differences. Chromatographic analysis of the labeled milk indicates a difference in distribution of the 47 Ca. From these data, the authors recommend the use of this assay system in calcium bioavailability studies. The labeling studies and comparisons indicate caution should be used, however, in labeling techniques and species milk comparison

  6. Evaluation of Blood-Based Antibody Rapid Testing for HIV Early Therapy: A Meta-Analysis of the Evidence

    Directory of Open Access Journals (Sweden)

    Xiaojie Huang

    2018-06-01

    Full Text Available BackgroundWestern blot (WB assay is considered the gold standard test for HIV infection confirmation. However, it requires technical expertise and is quite time-consuming. WHO recommends blood-based rapid diagnosis to achieve same-day test and treatment. However, this rapid testing strategy has not been promoted worldwide due to inadequate research evaluating the effectiveness of rapid tests (RTs as an alternative confirmatory HIV test for WB. This study aims to compare the diagnostic performance of rapid HIV tests compared with WB.MethodsPubMed and Web of Science were searched for publications on rapid HIV tests using blood specimen. A meta-analysis was performed to quantitatively evaluate the diagnostic performance of rapid HIV tests compared with the WB assay in terms of pooled sensitivity, specificity, area under summary receiver operating characteristic (SROC curve, and diagnostic odds ratio (DOR.ResultsTwenty articles involving 27,343 fresh specimens for rapid HIV tests were included in the meta-analysis. Regarding Capillus HIV-1/HIV-2, the pooled sensitivity, specificity, area under SROC curve, and DOR derived from six studies were 0.999 (95% CI, 0.956–1.000, 0.999 (95% CI, 0.991–1.00, 1.00 (95% CI, 0.99–1.00, and 1.0 × 106 (95% CI, 2.6 × 104–3.9 × 107 compared with the WB assay, respectively. With respect to Determine HIV-1/2, the pooled sensitivity, specificity area under SROC, and DOR derived from eight studies were 1.00 (95% CI, 0.789–1.000, 0.992 (95% CI, 0.985–0.996, 1.00 (95% CI, 0.99–1.00, and 1.8 × 106 (95% CI 406.049–7.8 × 109 compared with the WB assay, respectively. Regarding two-step serial RTs, the pooled sensitivity, specificity area under SROC, and DOR derived from eight studies were 0.998 (95% CI, 0.991–1.000, 0.998 (95% CI, 0.994–0.999, and 1.00 (95% CI 0.99–1.00 compared with the WB assay, respectively.ConclusionOur meta-analysis results may provide evidenced-based support

  7. Rapid solidification for preparation of high Tc superconductors

    International Nuclear Information System (INIS)

    Yavari, A.R.

    1988-01-01

    High Tc superconducting oxides are prepared in two different ways using rapid solidification: by oxidation of microcrystalline or amorphous tapes obtained by quenching the liquid alloy and via crystallisation of the amorphous oxide obtained by rapid quenching of the oxide melt. This technique is applied for the first time to the BiCaSrCuO family [fr

  8. Setting Component Priorities in Protecting NPPs against Cyber-Attacks Using Reliability Analysis Techniques

    International Nuclear Information System (INIS)

    Choi, Moon Kyoung; Seong, Poong Hyun; Son, Han Seong

    2017-01-01

    The digitalization of infrastructure makes systems vulnerable to cyber threats and hybrid attacks. According to ICS-CERT report, as time goes by, the number of vulnerabilities in ICS industries increases rapidly. Digital I and C systems have been developed and installed in nuclear power plants, and due to installation of the digital I and C systems, cyber security concerns are increasing in nuclear industry. However, there are too many critical digital assets to be inspected in digitalized NPPs. In order to reduce the inefficiency of regulation in nuclear facilities, the critical components that are directly related to an accident are elicited by using the reliability analysis techniques. Target initial events are selected, and their headings are analyzed through event tree analysis about whether the headings can be affected by cyber-attacks or not. Among the headings, the headings that can be proceeded directly to the core damage by the cyber-attack when they are fail are finally selected as the target of deriving the minimum cut-sets. We analyze the fault trees and derive the minimum set-cuts. In terms of original PSA, the value of probability for the cut-sets is important but the probability is not important in terms of cyber security of NPPs. The important factors is the number of basic events consisting of the minimal cut-sets that is proportional to vulnerability.

  9. Development of rapid urine analysis method for uranium

    Energy Technology Data Exchange (ETDEWEB)

    Kuwabara, J.; Noguchi, H. [Japan Atomic Energy Research Institute, Tokai, Ibaraki (Japan)

    2000-05-01

    ICP-MS has begun to spread in the field of individual monitoring for internal exposure as a very effective machine for uranium analysis. Although the ICP-MS has very high sensitivity, it requires longer time than conventional analysis, such as fluorescence analysis, because it is necessary to remove matrix from a urine sample sufficiently. To shorten time required for the urine bioassay by ICP-MS, a rapid uranium analysis method using the ICP-MS connected with a flow injection system was developed. Since this method does not involve chemical separation steps, the time required is equivalent to the conventional analysis. A measurement test was carried out using 10 urine solutions prepared from a urine sample. Required volume of urine solution is 5 ml. Main chemical treatment is only the digestion with 5 ml of nitric acid using a microwave oven to decompose organic matter and to dissolve suspended or precipitated matter. The microwave oven can digest 10 samples at once within an hour. Volume of digested sample solution was adjusted to 10 ml. The prepared sample solutions were directly introduced to the ICP-MS without any chemical separation procedure. The ICP-MS was connected with a flow injection system and an auto sampler. The flow injection system can minimize the matrix effects caused from salt dissolved in high matrix solution, such as non chemical separated urine sample, because it can introduce micro volume of sample solution into the ICP-MS. The ICP-MS detected uranium within 2 min/sample using the auto sampler. The 10 solutions prepared from a urine sample showed an average of 7.5 ng/l of uranium concentration in urine with 10 % standard deviation. A detection limit is about 1 ng/l. The total time required was less than 4 hours for 10 sample analysis. In the series of measurement, any memory effect was not observed. The present analysis method using the ICP-MS equipped with the flow injection system demonstrated that the shortening of time required on high

  10. Development of rapid urine analysis method for uranium

    International Nuclear Information System (INIS)

    Kuwabara, J.; Noguchi, H.

    2000-01-01

    ICP-MS has begun to spread in the field of individual monitoring for internal exposure as a very effective machine for uranium analysis. Although the ICP-MS has very high sensitivity, it requires longer time than conventional analysis, such as fluorescence analysis, because it is necessary to remove matrix from a urine sample sufficiently. To shorten time required for the urine bioassay by ICP-MS, a rapid uranium analysis method using the ICP-MS connected with a flow injection system was developed. Since this method does not involve chemical separation steps, the time required is equivalent to the conventional analysis. A measurement test was carried out using 10 urine solutions prepared from a urine sample. Required volume of urine solution is 5 ml. Main chemical treatment is only the digestion with 5 ml of nitric acid using a microwave oven to decompose organic matter and to dissolve suspended or precipitated matter. The microwave oven can digest 10 samples at once within an hour. Volume of digested sample solution was adjusted to 10 ml. The prepared sample solutions were directly introduced to the ICP-MS without any chemical separation procedure. The ICP-MS was connected with a flow injection system and an auto sampler. The flow injection system can minimize the matrix effects caused from salt dissolved in high matrix solution, such as non chemical separated urine sample, because it can introduce micro volume of sample solution into the ICP-MS. The ICP-MS detected uranium within 2 min/sample using the auto sampler. The 10 solutions prepared from a urine sample showed an average of 7.5 ng/l of uranium concentration in urine with 10 % standard deviation. A detection limit is about 1 ng/l. The total time required was less than 4 hours for 10 sample analysis. In the series of measurement, any memory effect was not observed. The present analysis method using the ICP-MS equipped with the flow injection system demonstrated that the shortening of time required on high

  11. Hardness and microstructural characteristics of rapidly solidified Al-8-16 wt.%Si alloys

    International Nuclear Information System (INIS)

    Uzun, O.; Karaaslan, T.; Gogebakan, M.; Keskin, M.

    2004-01-01

    Al-Si alloys with nominal composition of Al-8 wt.%Si, Al-12 wt.%Si, and Al-16 wt.%Si were rapidly solidified by using melt-spinning technique to examine the influence of the cooling rate/conditions on microstructure and mechanical properties. The microstructures of the rapidly solidified ribbons and ingot samples were investigated by the optical microscopy, electron microscopy and X-ray diffraction (XRD) techniques. The results showed that the structures of all melt-spun ribbons were completely composed of finely dispersed α-Al and eutectic Si phase, and primary silicon was not observed. The XRD analysis indicated that the solubility of Si in the α-Al matrix was greatly increased with rapid solidification. Additionally, mechanical properties of both conventionally cast (ingot) and melt-spun ribbons were examined by using Vickers indenter for one applied load (0.098 N). The hardness values of the melt-spun ribbons were about three times higher than those of ingot counterparts. The high hardness of the rapidly solidified state can be attributed to the supersaturated solid solutions. Besides, hardness values with different applied loads were measured for melt-spun ribbons. The results indicated that Vickers hardness values (H v ) of the ribbons depended on the applied load. Applying the concept of Hays-Kendall, the load independent hardness values were calculated as 694.0, 982.8 and 1186.8 MN/m 2 for Al-8 wt.%Si, Al-12 wt.%Si and Al-16 wt.%Si, respectively

  12. A survey on reliability and safety analysis techniques of robot systems in nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Eom, H S; Kim, J H; Lee, J C; Choi, Y R; Moon, S S

    2000-12-01

    The reliability and safety analysis techniques was surveyed for the purpose of overall quality improvement of reactor inspection system which is under development in our current project. The contents of this report are : 1. Reliability and safety analysis techniques suvey - Reviewed reliability and safety analysis techniques are generally accepted techniques in many industries including nuclear industry. And we selected a few techniques which are suitable for our robot system. They are falut tree analysis, failure mode and effect analysis, reliability block diagram, markov model, combinational method, and simulation method. 2. Survey on the characteristics of robot systems which are distinguished from other systems and which are important to the analysis. 3. Survey on the nuclear environmental factors which affect the reliability and safety analysis of robot system 4. Collection of the case studies of robot reliability and safety analysis which are performed in foreign countries. The analysis results of this survey will be applied to the improvement of reliability and safety of our robot system and also will be used for the formal qualification and certification of our reactor inspection system.

  13. A survey on reliability and safety analysis techniques of robot systems in nuclear power plants

    International Nuclear Information System (INIS)

    Eom, H.S.; Kim, J.H.; Lee, J.C.; Choi, Y.R.; Moon, S.S.

    2000-12-01

    The reliability and safety analysis techniques was surveyed for the purpose of overall quality improvement of reactor inspection system which is under development in our current project. The contents of this report are : 1. Reliability and safety analysis techniques suvey - Reviewed reliability and safety analysis techniques are generally accepted techniques in many industries including nuclear industry. And we selected a few techniques which are suitable for our robot system. They are falut tree analysis, failure mode and effect analysis, reliability block diagram, markov model, combinational method, and simulation method. 2. Survey on the characteristics of robot systems which are distinguished from other systems and which are important to the analysis. 3. Survey on the nuclear environmental factors which affect the reliability and safety analysis of robot system 4. Collection of the case studies of robot reliability and safety analysis which are performed in foreign countries. The analysis results of this survey will be applied to the improvement of reliability and safety of our robot system and also will be used for the formal qualification and certification of our reactor inspection system

  14. A rapid chemical method for lysing Arabidopsis cells for protein analysis

    Directory of Open Access Journals (Sweden)

    Takano Tetsuo

    2011-07-01

    Full Text Available Abstract Background Protein extraction is a frequent procedure in biological research. For preparation of plant cell extracts, plant materials usually have to be ground and homogenized to physically break the robust cell wall, but this step is laborious and time-consuming when a large number of samples are handled at once. Results We developed a chemical method for lysing Arabidopsis cells without grinding. In this method, plants are boiled for just 10 minutes in a solution containing a Ca2+ chelator and detergent. Cell extracts prepared by this method were suitable for SDS-PAGE and immunoblot analysis. This method was also applicable to genomic DNA extraction for PCR analysis. Our method was applied to many other plant species, and worked well for some of them. Conclusions Our method is rapid and economical, and allows many samples to be prepared simultaneously for protein analysis. Our method is useful not only for Arabidopsis research but also research on certain other species.

  15. A novel model-free data analysis technique based on clustering in a mutual information space: application to resting-state fMRI

    Directory of Open Access Journals (Sweden)

    Simon Benjaminsson

    2010-08-01

    Full Text Available Non-parametric data-driven analysis techniques can be used to study datasets with few assumptions about the data and underlying experiment. Variations of Independent Component Analysis (ICA have been the methods mostly used on fMRI data, e.g. in finding resting-state networks thought to reflect the connectivity of the brain. Here we present a novel data analysis technique and demonstrate it on resting-state fMRI data. It is a generic method with few underlying assumptions about the data. The results are built from the statistical relations between all input voxels, resulting in a whole-brain analysis on a voxel level. It has good scalability properties and the parallel implementation is capable of handling large datasets and databases. From the mutual information between the activities of the voxels over time, a distance matrix is created for all voxels in the input space. Multidimensional scaling is used to put the voxels in a lower-dimensional space reflecting the dependency relations based on the distance matrix. By performing clustering in this space we can find the strong statistical regularities in the data, which for the resting-state data turns out to be the resting-state networks. The decomposition is performed in the last step of the algorithm and is computationally simple. This opens up for rapid analysis and visualization of the data on different spatial levels, as well as automatically finding a suitable number of decomposition components.

  16. Patient specific ankle-foot orthoses using rapid prototyping

    Directory of Open Access Journals (Sweden)

    Sivak Seth

    2011-01-01

    Full Text Available Abstract Background Prefabricated orthotic devices are currently designed to fit a range of patients and therefore they do not provide individualized comfort and function. Custom-fit orthoses are superior to prefabricated orthotic devices from both of the above-mentioned standpoints. However, creating a custom-fit orthosis is a laborious and time-intensive manual process performed by skilled orthotists. Besides, adjustments made to both prefabricated and custom-fit orthoses are carried out in a qualitative manner. So both comfort and function can potentially suffer considerably. A computerized technique for fabricating patient-specific orthotic devices has the potential to provide excellent comfort and allow for changes in the standard design to meet the specific needs of each patient. Methods In this paper, 3D laser scanning is combined with rapid prototyping to create patient-specific orthoses. A novel process was engineered to utilize patient-specific surface data of the patient anatomy as a digital input, manipulate the surface data to an optimal form using Computer Aided Design (CAD software, and then download the digital output from the CAD software to a rapid prototyping machine for fabrication. Results Two AFOs were rapidly prototyped to demonstrate the proposed process. Gait analysis data of a subject wearing the AFOs indicated that the rapid prototyped AFOs performed comparably to the prefabricated polypropylene design. Conclusions The rapidly prototyped orthoses fabricated in this study provided good fit of the subject's anatomy compared to a prefabricated AFO while delivering comparable function (i.e. mechanical effect on the biomechanics of gait. The rapid fabrication capability is of interest because it has potential for decreasing fabrication time and cost especially when a replacement of the orthosis is required.

  17. A computer-controlled system for rapid soil analysis of 226Ra

    International Nuclear Information System (INIS)

    Doane, R.W.; Berven, B.A.; Blair, M.S.

    1984-01-01

    A computer-controlled multichannel analysis system has been developed by the Radiological Survey Activities (RASA) Group at Oak Ridge National Laboratory (ORNL) for the Department of Energy (DOE) in support of the DOE's remedial action programs. The purpose of this system is to provide a rapid estimate of the 226 Ra concentration in soil samples using a 6 x 9 inch NaI(T1) crystal containing a 3.25 inch deep by 3.5 inch diameter well. This gamma detection system is controlled by a minicomputer with a dual floppy disk storage medium, line printer, and optional X-Y plotter. A two-chip interface was also designed at ORNL which handles all control signals generated from the computer keyboard. These computer-generated control signals are processed in machine language for rapid data transfer and BASIC language is used for data processing. The computer system is a Commodore Business Machines (CBM) Model 8032 personal computer with CBM peripherals. Control and data signals are utilized via the parallel user's port to the interface unit. The analog-to-digital converter (ADC) is controlled in machine language, bootstrapped to high memory, and is addressed through the BASIC program. The BASIC program is designed to be ''user friendly'' and provides the operator with several modes of operation such as background and analysis acquisition. Any number of energy regions-of-interest (ROI) may be analyzed with automatic background substraction. Also employed in the BASIC program are the 226 Ra algorithms which utilize linear and polynomial regression equations for data conversion and look-up tables for radon equilibrating coefficients. The optional X-Y plotter may be used with two- or three-dimensional curve programs to enhance data analysis and presentation. A description of the system is presented and typical applications are discussed

  18. Rapid Analysis of Ash Composition Using Laser-Induced Breakdown Spectroscopy (LIBS)

    Energy Technology Data Exchange (ETDEWEB)

    Tyler L. Westover

    2013-01-01

    Inorganic compounds are known to be problematic in the thermochemical conversion of biomass to syngas and ultimately hydrocarbon fuels. The elements Si, K, Ca, Na, S, P, Cl, Mg, Fe, and Al are particularly problematic and are known to influence reaction pathways, contribute to fouling and corrosion, poison catalysts, and impact waste streams. Substantial quantities of inorganic species can be entrained in the bark of trees during harvest operations. Herbaceous feedstocks often have even greater quantities of inorganic constituents, which can account for as much as one-fifth of the total dry matter. Current methodologies to measure the concentrations of these elements, such as inductively coupled plasma-optical emission spectrometry/mass spectrometry (ICP-OES/MS) are expensive in time and reagents. This study demonstrates that a new methodology employing laser-induced breakdown spectroscopy (LIBS) can rapidly and accurately analyze the inorganic constituents in a wide range of biomass materials, including both woody and herbaceous examples. This technique requires little or no sample preparation, does not consume any reagents, and the analytical data is available immediately. In addition to comparing LIBS data with the results from ICP-OES methods, this work also includes discussions of sample preparation techniques, calibration curves for interpreting LIBS spectra, minimum detection limits, and the use of internal standards and standard reference materials.

  19. Aggregation factor analysis for protein formulation by a systematic approach using FTIR, SEC and design of experiments techniques.

    Science.gov (United States)

    Feng, Yan Wen; Ooishi, Ayako; Honda, Shinya

    2012-01-05

    A simple systematic approach using Fourier transform infrared (FTIR) spectroscopy, size exclusion chromatography (SEC) and design of experiments (DOE) techniques was applied to the analysis of aggregation factors for protein formulations in stress and accelerated testings. FTIR and SEC were used to evaluate protein conformational and storage stabilities, respectively. DOE was used to determine the suitable formulation and to analyze both the main effect of single factors and the interaction effect of combined factors on aggregation. Our results indicated that (i) analysis at a low protein concentration is not always applicable to high concentration formulations; (ii) an investigation of interaction effects of combined factors as well as main effects of single factors is effective for improving conformational stability of proteins; (iii) with the exception of pH, the results of stress testing with regard to aggregation factors would be available for suitable formulation instead of performing time-consuming accelerated testing; (iv) a suitable pH condition should not be determined in stress testing but in accelerated testing, because of inconsistent effects of pH on conformational and storage stabilities. In summary, we propose a three-step strategy, using FTIR, SEC and DOE techniques, to effectively analyze the aggregation factors and perform a rapid screening for suitable conditions of protein formulation. Copyright © 2011 Elsevier B.V. All rights reserved.

  20. Digital radiographic techniques in the analysis of paintings

    International Nuclear Information System (INIS)

    James, A.E. Jr.; Gibbs, S.J.; James, A.E. III; Pickens, D.R.; Sloan, M.; Price, R.R.; Erickson, J.J.

    1985-01-01

    In this chapter the authors use the term digital radiography to mean any method of radiographic image production in which the silver halide-based film is replaced by an electronic sensor for production of an image. There are essentially three types of digital radiographic systems available at present, but others will be developed. These differ primarily in the method of image production and the rapidity with which images can be produced. The three methods discussed are digital fluoroscopy, scanned projection radiography, and the scanned point source radiography. Each has certain characteristics which, if properly utilized, will allow improved x-ray analysis of paintings

  1. Ion beam analysis techniques applied to large scale pollution studies

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, D D; Bailey, G; Martin, J; Garton, D; Noorman, H; Stelcer, E; Johnson, P [Australian Nuclear Science and Technology Organisation, Lucas Heights, NSW (Australia)

    1994-12-31

    Ion Beam Analysis (IBA) techniques are ideally suited to analyse the thousands of filter papers a year that may originate from a large scale aerosol sampling network. They are fast multi-elemental and, for the most part, non-destructive so other analytical methods such as neutron activation and ion chromatography can be performed afterwards. ANSTO in collaboration with the NSW EPA, Pacific Power and the Universities of NSW and Macquarie has established a large area fine aerosol sampling network covering nearly 80,000 square kilometres of NSW with 25 fine particle samplers. This network known as ASP was funded by the Energy Research and Development Corporation (ERDC) and commenced sampling on 1 July 1991. The cyclone sampler at each site has a 2.5 {mu}m particle diameter cut off and runs for 24 hours every Sunday and Wednesday using one Gillman 25mm diameter stretched Teflon filter for each day. These filters are ideal targets for ion beam analysis work. Currently ANSTO receives 300 filters per month from this network for analysis using its accelerator based ion beam techniques on the 3 MV Van de Graaff accelerator. One week a month of accelerator time is dedicated to this analysis. Four simultaneous accelerator based IBA techniques are used at ANSTO, to analyse for the following 24 elements: H, C, N, O, F, Na, Al, Si, P, S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Cu, Ni, Co, Zn, Br and Pb. The IBA techniques were proved invaluable in identifying sources of fine particles and their spatial and seasonal variations accross the large area sampled by the ASP network. 3 figs.

  2. Ion beam analysis techniques applied to large scale pollution studies

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, D.D.; Bailey, G.; Martin, J.; Garton, D.; Noorman, H.; Stelcer, E.; Johnson, P. [Australian Nuclear Science and Technology Organisation, Lucas Heights, NSW (Australia)

    1993-12-31

    Ion Beam Analysis (IBA) techniques are ideally suited to analyse the thousands of filter papers a year that may originate from a large scale aerosol sampling network. They are fast multi-elemental and, for the most part, non-destructive so other analytical methods such as neutron activation and ion chromatography can be performed afterwards. ANSTO in collaboration with the NSW EPA, Pacific Power and the Universities of NSW and Macquarie has established a large area fine aerosol sampling network covering nearly 80,000 square kilometres of NSW with 25 fine particle samplers. This network known as ASP was funded by the Energy Research and Development Corporation (ERDC) and commenced sampling on 1 July 1991. The cyclone sampler at each site has a 2.5 {mu}m particle diameter cut off and runs for 24 hours every Sunday and Wednesday using one Gillman 25mm diameter stretched Teflon filter for each day. These filters are ideal targets for ion beam analysis work. Currently ANSTO receives 300 filters per month from this network for analysis using its accelerator based ion beam techniques on the 3 MV Van de Graaff accelerator. One week a month of accelerator time is dedicated to this analysis. Four simultaneous accelerator based IBA techniques are used at ANSTO, to analyse for the following 24 elements: H, C, N, O, F, Na, Al, Si, P, S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Cu, Ni, Co, Zn, Br and Pb. The IBA techniques were proved invaluable in identifying sources of fine particles and their spatial and seasonal variations accross the large area sampled by the ASP network. 3 figs.

  3. Comparative analysis of the aroma chemicals of Melissa officinalis using hydrodistillation and HS-SPME techniques

    Directory of Open Access Journals (Sweden)

    Shakeel-u- Rehman

    2017-05-01

    Full Text Available Headspace solid-phase micro extraction (HS-SPME coupled with gas chromatography–mass spectrometry (GC–MS has been used for the chemical analysis of Melissa officinalis (leaves cultivated in Institute Germplasm. The HS-SPME analysis led to the identification of 22 components constituting 99.1% of the total volatile constituents present in the leaves whereas its hydrodistillate led to the identification of 24 volatile constituents constituting 98.1% of the volatile material. The chemical composition of the SPME and hydrodistilled extract of M. officinalis leaves comprised mainly of oxygenated monoterpenes (78.5% and 57.8% respectively and sesquiterpene hydrocarbons (14.9% and 29.7% respectively. The major components identified in the HS-SPME extract were citronellal (31.1%, citronellol (18.3%, β-caryophyllene (12.0%, (E-citral (11.9%, (Z-citral (9.6%, geraniol (3.6%, (Z-β-ocimene (3.1% and 1-octen-3-ol (2.0% whereas hydrodistilled essential oil was rich in (Z-citral (19.6%, β-caryophyllene (13.2%, (E-citral (11.2%, citronellal (10.2%, germacrene-d (8.3%, δ-3-carene (5.0%, 6-methyl-5-hepten-2-one (3.7% and citronellyl acetate (3.7%. The comparative analysis of volatile constituents of M. officinalis leaf extract using HS-SPME and hydrodistillation techniques shows both qualitative as well as quantitative differences. The current study is the first report involving rapid analysis of volatile components of M. officinalis by HS-SPME.

  4. An automated robotic platform for rapid profiling oligosaccharide analysis of monoclonal antibodies directly from cell culture.

    Science.gov (United States)

    Doherty, Margaret; Bones, Jonathan; McLoughlin, Niaobh; Telford, Jayne E; Harmon, Bryan; DeFelippis, Michael R; Rudd, Pauline M

    2013-11-01

    Oligosaccharides attached to Asn297 in each of the CH2 domains of monoclonal antibodies play an important role in antibody effector functions by modulating the affinity of interaction with Fc receptors displayed on cells of the innate immune system. Rapid, detailed, and quantitative N-glycan analysis is required at all stages of bioprocess development to ensure the safety and efficacy of the therapeutic. The high sample numbers generated during quality by design (QbD) and process analytical technology (PAT) create a demand for high-performance, high-throughput analytical technologies for comprehensive oligosaccharide analysis. We have developed an automated 96-well plate-based sample preparation platform for high-throughput N-glycan analysis using a liquid handling robotic system. Complete process automation includes monoclonal antibody (mAb) purification directly from bioreactor media, glycan release, fluorescent labeling, purification, and subsequent ultra-performance liquid chromatography (UPLC) analysis. The entire sample preparation and commencement of analysis is achieved within a 5-h timeframe. The automated sample preparation platform can easily be interfaced with other downstream analytical technologies, including mass spectrometry (MS) and capillary electrophoresis (CE), for rapid characterization of oligosaccharides present on therapeutic antibodies. Copyright © 2013 Elsevier Inc. All rights reserved.

  5. Machine monitoring via current signature analysis techniques

    International Nuclear Information System (INIS)

    Smith, S.F.; Castleberry, K.N.; Nowlin, C.H.

    1992-01-01

    A significant need in the effort to provide increased production quality is to provide improved plant equipment monitoring capabilities. Unfortunately, in today's tight economy, even such monitoring instrumentation must be implemented in a recognizably cost effective manner. By analyzing the electric current drawn by motors, actuator, and other line-powered industrial equipment, significant insights into the operations of the movers, driven equipment, and even the power source can be obtained. The generic term 'current signature analysis' (CSA) has been coined to describe several techniques for extracting useful equipment or process monitoring information from the electrical power feed system. A patented method developed at Oak Ridge National Laboratory is described which recognizes the presence of line-current modulation produced by motors and actuators driving varying loads. The in-situ application of applicable linear demodulation techniques to the analysis of numerous motor-driven systems is also discussed. The use of high-quality amplitude and angle-demodulation circuitry has permitted remote status monitoring of several types of medium and high-power gas compressors in (US DOE facilities) driven by 3-phase induction motors rated from 100 to 3,500 hp, both with and without intervening speed increasers. Flow characteristics of the compressors, including various forms of abnormal behavior such as surging and rotating stall, produce at the output of the specialized detectors specific time and frequency signatures which can be easily identified for monitoring, control, and fault-prevention purposes. The resultant data are similar in form to information obtained via standard vibration-sensing techniques and can be analyzed using essentially identical methods. In addition, other machinery such as refrigeration compressors, brine pumps, vacuum pumps, fans, and electric motors have been characterized

  6. Instrumental analysis of bacterial cells using vibrational and emission Moessbauer spectroscopic techniques

    International Nuclear Information System (INIS)

    Kamnev, Alexander A.; Tugarova, Anna V.; Antonyuk, Lyudmila P.; Tarantilis, Petros A.; Kulikov, Leonid A.; Perfiliev, Yurii D.; Polissiou, Moschos G.; Gardiner, Philip H.E.

    2006-01-01

    In biosciences and biotechnology, the expanding application of physicochemical approaches using modern instrumental techniques is an efficient strategy to obtain valuable and often unique information at the molecular level. In this work, we applied a combination of vibrational (Fourier transform infrared (FTIR), FT-Raman) spectroscopic techniques, useful in overall structural and compositional analysis of bacterial cells of the rhizobacterium Azospirillum brasilense, with 57 Co emission Moessbauer spectroscopy (EMS) used for sensitive monitoring of metal binding and further transformations in live bacterial cells. The information obtained, together with ICP-MS analyses for metals taken up by the bacteria, is useful in analysing the impact of the environmental conditions (heavy metal stress) on the bacterial metabolism and some differences in the heavy metal stress-induced behaviour of non-endophytic (Sp7) and facultatively endophytic (Sp245) strains. The results show that, while both strains Sp7 and Sp245 take up noticeable and comparable amounts of heavy metals from the medium (0.12 and 0.13 mg Co, 0.48 and 0.44 mg Cu or 4.2 and 2.1 mg Zn per gram of dry biomass, respectively, at a metal concentration of 0.2 mM in the medium), their metabolic responses differ essentially. Whereas for strain Sp7 the FTIR measurements showed significant accumulation of polyhydroxyalkanoates as storage materials involved in stress endurance, strain Sp245 did not show any major changes in cellular composition. Nevertheless, EMS measurements showed rapid binding of cobalt(II) by live bacterial cells (chemically similar to metal binding by dead bacteria) and its further transformation in the live cells within an hour

  7. Instrumental analysis of bacterial cells using vibrational and emission Moessbauer spectroscopic techniques

    Energy Technology Data Exchange (ETDEWEB)

    Kamnev, Alexander A. [Laboratory of Biochemistry of Plant-Bacterial Symbioses, Institute of Biochemistry and Physiology of Plants and Microorganisms, Russian Academy of Sciences, 410049 Saratov (Russian Federation)]. E-mail: aakamnev@ibppm.sgu.ru; Tugarova, Anna V. [Laboratory of Biochemistry of Plant-Bacterial Symbioses, Institute of Biochemistry and Physiology of Plants and Microorganisms, Russian Academy of Sciences, 410049 Saratov (Russian Federation); Antonyuk, Lyudmila P. [Laboratory of Biochemistry of Plant-Bacterial Symbioses, Institute of Biochemistry and Physiology of Plants and Microorganisms, Russian Academy of Sciences, 410049 Saratov (Russian Federation); Tarantilis, Petros A. [Laboratory of Chemistry, Department of Science, Agricultural University of Athens, 11855 Athens (Greece); Kulikov, Leonid A. [Laboratory of Nuclear Chemistry Techniques, Department of Radiochemistry, Faculty of Chemistry, M.V. Lomonosov Moscow State University, 119992 Moscow (Russian Federation); Perfiliev, Yurii D. [Laboratory of Nuclear Chemistry Techniques, Department of Radiochemistry, Faculty of Chemistry, M.V. Lomonosov Moscow State University, 119992 Moscow (Russian Federation); Polissiou, Moschos G. [Laboratory of Chemistry, Department of Science, Agricultural University of Athens, 11855 Athens (Greece); Gardiner, Philip H.E. [Division of Chemistry, School of Science and Mathematics, Sheffield Hallam University, Sheffield S1 1WB (United Kingdom)

    2006-07-28

    In biosciences and biotechnology, the expanding application of physicochemical approaches using modern instrumental techniques is an efficient strategy to obtain valuable and often unique information at the molecular level. In this work, we applied a combination of vibrational (Fourier transform infrared (FTIR), FT-Raman) spectroscopic techniques, useful in overall structural and compositional analysis of bacterial cells of the rhizobacterium Azospirillum brasilense, with {sup 57}Co emission Moessbauer spectroscopy (EMS) used for sensitive monitoring of metal binding and further transformations in live bacterial cells. The information obtained, together with ICP-MS analyses for metals taken up by the bacteria, is useful in analysing the impact of the environmental conditions (heavy metal stress) on the bacterial metabolism and some differences in the heavy metal stress-induced behaviour of non-endophytic (Sp7) and facultatively endophytic (Sp245) strains. The results show that, while both strains Sp7 and Sp245 take up noticeable and comparable amounts of heavy metals from the medium (0.12 and 0.13 mg Co, 0.48 and 0.44 mg Cu or 4.2 and 2.1 mg Zn per gram of dry biomass, respectively, at a metal concentration of 0.2 mM in the medium), their metabolic responses differ essentially. Whereas for strain Sp7 the FTIR measurements showed significant accumulation of polyhydroxyalkanoates as storage materials involved in stress endurance, strain Sp245 did not show any major changes in cellular composition. Nevertheless, EMS measurements showed rapid binding of cobalt(II) by live bacterial cells (chemically similar to metal binding by dead bacteria) and its further transformation in the live cells within an hour.

  8. Search for the top quark using multivariate analysis techniques

    International Nuclear Information System (INIS)

    Bhat, P.C.

    1994-08-01

    The D0 collaboration is developing top search strategies using multivariate analysis techniques. We report here on applications of the H-matrix method to the eμ channel and neural networks to the e+jets channel

  9. Comparative Analysis of Some Techniques in the Biological ...

    African Journals Online (AJOL)

    The experiments involved the simulation of conditions of a major spill by pouring crude oil on the cells from perforated cans and the in-situ bioremediation of the polluted soils using the techniques that consisted in the manipulation of different variables within the soil environment. The analysis of soil characteristics after a ...

  10. Environmental impact assessment of structural flood mitigation measures by a rapid impact assessment matrix (RIAM) technique: a case study in Metro Manila, Philippines.

    Science.gov (United States)

    Gilbuena, Romeo; Kawamura, Akira; Medina, Reynaldo; Amaguchi, Hideo; Nakagawa, Naoko; Bui, Duong Du

    2013-07-01

    In recent decades, the practice of environmental impact assessment (EIA) in the planning processes of infrastructure projects has created significant awareness on the benefits of environmentally sound and sustainable urban development around the world. In the highly urbanized megacities in the Philippines, like Metro Manila, high priority is given by the national government to structural flood mitigation measures (SFMM) due to the persistently high frequency of flood-related disasters, which are exacerbated by the on-going effects of climate change. EIA thus, should be carefully and effectively executed to maximize the potential benefits of the SFMM. The common practice of EIA in the Philippines is generally qualitative and lacks clear methodology in evaluating multi-criteria systems. Thus, this study proposes the use of the rapid impact assessment matrix (RIAM) technique to provide a method that would systematically and quantitatively evaluate the socio-economic and environmental impacts of planned SFMM in Metro Manila. The RIAM technique was slightly modified to fit the requirements of this study. The scale of impact was determined for each perceived impact, and based on the results, the planned SFMM for Metro Manila will likely bring significant benefits; however, significant negative impacts may also likely occur. The proposed modifications were found to be highly compatible with RIAM, and the results of the RIAM analysis provided a clear view of the impacts associated with the implementation of SFMM projects. This may prove to be valuable in the practice of EIA in the Philippines. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. Radio-analysis. Definitions and techniques

    International Nuclear Information System (INIS)

    Bourrel, F.; Courriere, Ph.

    2003-01-01

    This paper presents the different steps of the radio-labelling of a molecule for two purposes: the radio-immuno-analysis and the auto-radiography: 1 - definitions, radiations and radioprotection: activity of a radioactive source; half-life; radioactivity (alpha-, beta- and gamma radioactivity, internal conversion); radioprotection (irradiation, contamination); 2 - radionuclides used in medical biology and obtention of labelled molecules: gamma emitters ( 125 I, 57 Co); beta emitters; obtention of labelled molecules (general principles, high specific activity and choice of the tracer, molecule to be labelled); main labelling techniques (iodation, tritium); purification of the labelled compound (dialysis, gel-filtering or molecular exclusion chromatography, high performance liquid chromatography); quality estimation of the labelled compound (labelling efficiency calculation, immuno-reactivity conservation, stability and preservation). (J.S.)

  12. The Statistical Analysis Techniques to Support the NGNP Fuel Performance Experiments

    International Nuclear Information System (INIS)

    Pham, Bihn T.; Einerson, Jeffrey J.

    2010-01-01

    This paper describes the development and application of statistical analysis techniques to support the AGR experimental program on NGNP fuel performance. The experiments conducted in the Idaho National Laboratory's Advanced Test Reactor employ fuel compacts placed in a graphite cylinder shrouded by a steel capsule. The tests are instrumented with thermocouples embedded in graphite blocks and the target quantity (fuel/graphite temperature) is regulated by the He-Ne gas mixture that fills the gap volume. Three techniques for statistical analysis, namely control charting, correlation analysis, and regression analysis, are implemented in the SAS-based NGNP Data Management and Analysis System (NDMAS) for automated processing and qualification of the AGR measured data. The NDMAS also stores daily neutronic (power) and thermal (heat transfer) code simulation results along with the measurement data, allowing for their combined use and comparative scrutiny. The ultimate objective of this work includes (a) a multi-faceted system for data monitoring and data accuracy testing, (b) identification of possible modes of diagnostics deterioration and changes in experimental conditions, (c) qualification of data for use in code validation, and (d) identification and use of data trends to support effective control of test conditions with respect to the test target. Analysis results and examples given in the paper show the three statistical analysis techniques providing a complementary capability to warn of thermocouple failures. It also suggests that the regression analysis models relating calculated fuel temperatures and thermocouple readings can enable online regulation of experimental parameters (i.e. gas mixture content), to effectively maintain the target quantity (fuel temperature) within a given range.

  13. The statistical analysis techniques to support the NGNP fuel performance experiments

    Energy Technology Data Exchange (ETDEWEB)

    Pham, Binh T., E-mail: Binh.Pham@inl.gov; Einerson, Jeffrey J.

    2013-10-15

    This paper describes the development and application of statistical analysis techniques to support the Advanced Gas Reactor (AGR) experimental program on Next Generation Nuclear Plant (NGNP) fuel performance. The experiments conducted in the Idaho National Laboratory’s Advanced Test Reactor employ fuel compacts placed in a graphite cylinder shrouded by a steel capsule. The tests are instrumented with thermocouples embedded in graphite blocks and the target quantity (fuel temperature) is regulated by the He–Ne gas mixture that fills the gap volume. Three techniques for statistical analysis, namely control charting, correlation analysis, and regression analysis, are implemented in the NGNP Data Management and Analysis System for automated processing and qualification of the AGR measured data. The neutronic and thermal code simulation results are used for comparative scrutiny. The ultimate objective of this work includes (a) a multi-faceted system for data monitoring and data accuracy testing, (b) identification of possible modes of diagnostics deterioration and changes in experimental conditions, (c) qualification of data for use in code validation, and (d) identification and use of data trends to support effective control of test conditions with respect to the test target. Analysis results and examples given in the paper show the three statistical analysis techniques providing a complementary capability to warn of thermocouple failures. It also suggests that the regression analysis models relating calculated fuel temperatures and thermocouple readings can enable online regulation of experimental parameters (i.e. gas mixture content), to effectively maintain the fuel temperature within a given range.

  14. Image Analysis Technique for Material Behavior Evaluation in Civil Structures

    Science.gov (United States)

    Moretti, Michele; Rossi, Gianluca

    2017-01-01

    The article presents a hybrid monitoring technique for the measurement of the deformation field. The goal is to obtain information about crack propagation in existing structures, for the purpose of monitoring their state of health. The measurement technique is based on the capture and analysis of a digital image set. Special markers were used on the surface of the structures that can be removed without damaging existing structures as the historical masonry. The digital image analysis was done using software specifically designed in Matlab to follow the tracking of the markers and determine the evolution of the deformation state. The method can be used in any type of structure but is particularly suitable when it is necessary not to damage the surface of structures. A series of experiments carried out on masonry walls of the Oliverian Museum (Pesaro, Italy) and Palazzo Silvi (Perugia, Italy) have allowed the validation of the procedure elaborated by comparing the results with those derived from traditional measuring techniques. PMID:28773129

  15. BATMAN: Bayesian Technique for Multi-image Analysis

    Science.gov (United States)

    Casado, J.; Ascasibar, Y.; García-Benito, R.; Guidi, G.; Choudhury, O. S.; Bellocchi, E.; Sánchez, S. F.; Díaz, A. I.

    2017-04-01

    This paper describes the Bayesian Technique for Multi-image Analysis (BATMAN), a novel image-segmentation technique based on Bayesian statistics that characterizes any astronomical data set containing spatial information and performs a tessellation based on the measurements and errors provided as input. The algorithm iteratively merges spatial elements as long as they are statistically consistent with carrying the same information (I.e. identical signal within the errors). We illustrate its operation and performance with a set of test cases including both synthetic and real integral-field spectroscopic data. The output segmentations adapt to the underlying spatial structure, regardless of its morphology and/or the statistical properties of the noise. The quality of the recovered signal represents an improvement with respect to the input, especially in regions with low signal-to-noise ratio. However, the algorithm may be sensitive to small-scale random fluctuations, and its performance in presence of spatial gradients is limited. Due to these effects, errors may be underestimated by as much as a factor of 2. Our analysis reveals that the algorithm prioritizes conservation of all the statistically significant information over noise reduction, and that the precise choice of the input data has a crucial impact on the results. Hence, the philosophy of BaTMAn is not to be used as a 'black box' to improve the signal-to-noise ratio, but as a new approach to characterize spatially resolved data prior to its analysis. The source code is publicly available at http://astro.ft.uam.es/SELGIFS/BaTMAn.

  16. A parylene-based dual channel microelectrophoresis system for rapid mutation detection via heteroduplex analysis

    NARCIS (Netherlands)

    Sukas, S.; Erson, Ayse Elif; Sert, Cuneyt; Kulah, Haluk

    2008-01-01

    A new dual channel micro-electrophoresis system for rapid mutation detection based on heteroduplex analysis was designed and implemented. Mutation detection was successfully achieved in a total separation length of 250 μm in less than 3 min for a 590 bp DNA sample harboring a 3 bp mutation causing

  17. Control charts technique - a tool to data analysis for chemical experiments

    International Nuclear Information System (INIS)

    Yadav, M.B.; Venugopal, V.

    1999-01-01

    A procedure using control charts technique has been developed to analyse data of a chemical experiment which was conducted to assign a value to uranium content in Rb 2 U(SO 4 ) 3 . A value of (34.164 ± 0.031)% has been assigned against (34.167 ± 0.042)% already assigned by analysis of variance (ANOVA) technique. These values do not differ significantly. Merits and demerits of the two techniques have been discussed. (author)

  18. Comparing dynamical systems concepts and techniques for biomechanical analysis

    OpenAIRE

    van Emmerik, Richard E.A.; Ducharme, Scott W.; Amado, Avelino C.; Hamill, Joseph

    2016-01-01

    Traditional biomechanical analyses of human movement are generally derived from linear mathematics. While these methods can be useful in many situations, they do not describe behaviors in human systems that are predominately nonlinear. For this reason, nonlinear analysis methods based on a dynamical systems approach have become more prevalent in recent literature. These analysis techniques have provided new insights into how systems (1) maintain pattern stability, (2) transition into new stat...

  19. Techniques of sample attack used in soil and mineral analysis. Phase I

    International Nuclear Information System (INIS)

    Chiu, N.W.; Dean, J.R.; Sill, C.W.

    1984-07-01

    Several techniques of sample attack for the determination of radioisotopes are reviewed. These techniques include: 1) digestion with nitric or hydrochloric acid in Parr digestion bomb, 2) digestion with a mixture of nitric and hydrochloric acids, 3) digestion with a mixture of hydrofluoric, nitric and perchloric acids, and 4) fusion with sodium carbonate, potassium fluoride or alkali pyrosulfates. The effectiveness of these techniques to decompose various soils and minerals containing radioisotopes such as lead-210 uranium, thorium and radium-226 are discussed. The combined procedure of potassium fluoride fusion followed by alkali pyrosulfate fusion is recommended for radium-226, uranium and thorium analysis. This technique guarantees the complete dissolution of samples containing refractory materials such as silica, silicates, carbides, oxides and sulfates. For the lead-210 analysis, the procedure of digestion with a mixture of hydrofluoric, nitric and perchloric acids followed by fusion with alkali pyrosulfate is recommended. These two procedures are detailed. Schemes for the sequential separation of the radioisotopes from a dissolved sample solution are outlined. Procedures for radiochemical analysis are suggested

  20. A comparative study of standard intensity-modulated radiotherapy and RapidArc planning techniques for ipsilateral and bilateral head and neck irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Pursley, Jennifer, E-mail: jpursley@mgh.harvard.edu [Department of Radiation Oncology, Dana-Farber Cancer Institute/Brigham and Women' s Hospital, Boston, MA (United States); Department of Radiation Oncology, Massachusetts General Hospital, Boston, MA (United States); Damato, Antonio L.; Czerminska, Maria A.; Margalit, Danielle N. [Department of Radiation Oncology, Dana-Farber Cancer Institute/Brigham and Women' s Hospital, Boston, MA (United States); Sher, David J. [Department of Radiation Oncology, Dana-Farber Cancer Institute/Brigham and Women' s Hospital, Boston, MA (United States); Department of Radiation Oncology, UT Southwestern Medical Center, Dallas, TX (United States); Tishler, Roy B. [Department of Radiation Oncology, Dana-Farber Cancer Institute/Brigham and Women' s Hospital, Boston, MA (United States)

    2017-04-01

    The purpose of this study was to investigate class solutions using RapidArc volumetric-modulated arc therapy (VMAT) planning for ipsilateral and bilateral head and neck (H&N) irradiation, and to compare dosimetric results with intensity-modulated radiotherapy (IMRT) plans. A total of 14 patients who received ipsilateral and 10 patients who received bilateral head and neck irradiation were retrospectively replanned with several volumetric-modulated arc therapy techniques. For ipsilateral neck irradiation, the volumetric-modulated arc therapy techniques included two 360° arcs, two 360° arcs with avoidance sectors around the contralateral parotid, two 260° or 270° arcs, and two 210° arcs. For bilateral neck irradiation, the volumetric-modulated arc therapy techniques included two 360° arcs, two 360° arcs with avoidance sectors around the shoulders, and 3 arcs. All patients had a sliding-window-delivery intensity-modulated radiotherapy plan that was used as the benchmark for dosimetric comparison. For ipsilateral neck irradiation, a volumetric-modulated arc therapy technique using two 360° arcs with avoidance sectors around the contralateral parotid was dosimetrically comparable to intensity-modulated radiotherapy, with improved conformity (conformity index = 1.22 vs 1.36, p < 0.04) and lower contralateral parotid mean dose (5.6 vs 6.8 Gy, p < 0.03). For bilateral neck irradiation, 3-arc volumetric-modulated arc therapy techniques were dosimetrically comparable to intensity-modulated radiotherapy while also avoiding irradiation through the shoulders. All volumetric-modulated arc therapy techniques required fewer monitor units than sliding-window intensity-modulated radiotherapy to deliver treatment, with an average reduction of 35% for ipsilateral plans and 67% for bilateral plans. Thus, for ipsilateral head and neck irradiation a volumetric-modulated arc therapy technique using two 360° arcs with avoidance sectors around the contralateral parotid is

  1. Arabidopsis seedling flood-inoculation technique: a rapid and reliable assay for studying plant-bacterial interactions

    Directory of Open Access Journals (Sweden)

    Uppalapati Srinivasa R

    2011-10-01

    Full Text Available Abstract Background The Arabidopsis thaliana-Pseudomonas syringae model pathosystem is one of the most widely used systems to understand the mechanisms of microbial pathogenesis and plant innate immunity. Several inoculation methods have been used to study plant-pathogen interactions in this model system. However, none of the methods reported to date are similar to those occurring in nature and amicable to large-scale mutant screens. Results In this study, we developed a rapid and reliable seedling flood-inoculation method based on young Arabidopsis seedlings grown on MS medium. This method has several advantages over conventional soil-grown plant inoculation assays, including a shorter growth and incubation period, ease of inoculation and handling, uniform infection and disease development, requires less growth chamber space and is suitable for high-throughput screens. In this study we demonstrated the efficacy of the Arabidopsis seedling assay to study 1 the virulence factors of P. syringae pv. tomato DC3000, including type III protein secretion system (TTSS and phytotoxin coronatine (COR; 2 the effector-triggered immunity; and 3 Arabidopsis mutants affected in salicylic acid (SA- and pathogen-associated molecular pattern (PAMPs-mediated pathways. Furthermore, we applied this technique to study nonhost resistance (NHR responses in Arabidopsis using nonhost pathogens, such as P. syringae pv. tabaci, pv. glycinea and pv. tomato T1, and confirmed the functional role of FLAGELLIN-SENSING 2 (FLS2 in NHR. Conclusions The Arabidopsis seedling flood-inoculation assay provides a rapid, efficient and economical method for studying Arabidopsis-Pseudomonas interactions with minimal growth chamber space and time. This assay could also provide an excellent system for investigating the virulence mechanisms of P. syringae. Using this method, we demonstrated that FLS2 plays a critical role in conferring NHR against nonhost pathovars of P. syringae, but not to

  2. Electrospun fibrous thin film microextraction coupled with desorption corona beam ionization-mass spectrometry for rapid analysis of antidepressants in human plasma.

    Science.gov (United States)

    Chen, Di; Hu, Yu-Ning; Hussain, Dilshad; Zhu, Gang-Tian; Huang, Yun-Qing; Feng, Yu-Qi

    2016-05-15

    Appropriate sample preparations prior to analysis can significantly enhance the sensitivity of ambient ionization techniques, especially during the enrichment or purification of analytes in the presence of complex biological matrix. Here in, we developed a rapid analysis method by the combination of thin film microextraction (TFME) and desorption corona beam ionization (DCBI) for the determination of antidepressants in human plasma. Thin films used for extraction consisted of sub-micron sized highly ordered mesoporous silica-carbon composite fibers (OMSCFs), simply prepared by electrospinning and subsequent carbonization. Typically, OMSCFs thin film was immersed into the diluted plasma for extraction of target analytes and then directly subjected to the DCBI-MS for detection. Size-exclusion effect of mesopores contributed to avoid of the protein precipitation step prior to extraction. Mass transfer was benefited from high surface-to-volume ratio which is attributed to macroporous network and ordered mesostructures. Moreover, the OMSCFs provided mixed-mode hydrophobic/ion-exchange interactions towards target analytes. Thus, the detection sensitivity was greatly improved due to effective enrichment of the target analytes and elimination of matrix interferences. After optimization of several parameters related to extraction performance, the proposed method was eventually applied for the determination of three antidepressants in human plasma. The calibration curves were plotted in the range of 5-1000 ng/mL with acceptable linearity (R(2) >0.983). The limits of detection (S/N=3) of three antidepressants were in ranges of 0.3-1 ng/mL. Reproducibility was achieved with RSD less than 17.6% and the relative recoveries were in ranges of 83.6-116.9%. Taken together, TFME-DCBI-MS method offers a powerful capacity for rapid analysis to achieve much-improved sensitivity. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Rapid hydrogen hydrate growth from non-stoichiometric tuning mixtures during liquid nitrogen quenching.

    Science.gov (United States)

    Grim, R Gary; Kerkar, Prasad B; Sloan, E Dendy; Koh, Carolyn A; Sum, Amadeu K

    2012-06-21

    In this study the rapid growth of sII H(2) hydrate within 20 min of post formation quenching towards liquid nitrogen (LN(2)) temperature is presented. Initially at 72 MPa and 258 K, hydrate samples would cool to the conditions of ~60 MPa and ~90 K after quenching. Although within the stability region for H(2) hydrate, new hydrate growth only occurred under LN(2) quenching of the samples when preformed hydrate "seeds" of THF + H(2) were in the presence of unconverted ice. The characterization of hydrate seeds and the post-quenched samples was performed with confocal Raman spectroscopy. These results suggest that quenching to LN(2) temperature, a common preservation technique for ex situ hydrate analysis, can lead to rapid unintended hydrate growth. Specifically, guest such as H(2) that may otherwise need sufficiently long induction periods to nucleate, may still experience rapid growth through an increased kinetic effect from a preformed hydrate template.

  4. Practical applications of activation analysis and other nuclear techniques

    International Nuclear Information System (INIS)

    Lyon, W.S.

    1982-01-01

    Neeutron activation analysis (NAA) is a versatile, sensitive multielement, usually nondestructive analytical technique used to determine elemental concentrations in a variety of materials. Samples are irradiated with neutrons in a nuclear reactor, removed, and for the nondestructive technique, the induced radioactivity measured. This measurement of γ rays emitted from specific radionuclides makes possible the quantitative determination of elements present. The method is described, advantages and disadvantages listed and a number of examples of its use given. Two other nuclear methods, particle induced x-ray emission and synchrotron produced x-ray fluorescence are also briefly discussed

  5. Tailored Cloze: Improved with Classical Item Analysis Techniques.

    Science.gov (United States)

    Brown, James Dean

    1988-01-01

    The reliability and validity of a cloze procedure used as an English-as-a-second-language (ESL) test in China were improved by applying traditional item analysis and selection techniques. The 'best' test items were chosen on the basis of item facility and discrimination indices, and were administered as a 'tailored cloze.' 29 references listed.…

  6. The application of two recently developed human reliability techniques to cognitive error analysis

    International Nuclear Information System (INIS)

    Gall, W.

    1990-01-01

    Cognitive error can lead to catastrophic consequences for manned systems, including those whose design renders them immune to the effects of physical slips made by operators. Four such events, pressurized water and boiling water reactor accidents which occurred recently, were analysed. The analysis identifies the factors which contributed to the errors and suggests practical strategies for error recovery or prevention. Two types of analysis were conducted: an unstructured analysis based on the analyst's knowledge of psychological theory, and a structured analysis using two recently-developed human reliability analysis techniques. In general, the structured techniques required less effort to produce results and these were comparable to those of the unstructured analysis. (author)

  7. Optical Coherence Tomography in the UK Biobank Study - Rapid Automated Analysis of Retinal Thickness for Large Population-Based Studies.

    Directory of Open Access Journals (Sweden)

    Pearse A Keane

    Full Text Available To describe an approach to the use of optical coherence tomography (OCT imaging in large, population-based studies, including methods for OCT image acquisition, storage, and the remote, rapid, automated analysis of retinal thickness.In UK Biobank, OCT images were acquired between 2009 and 2010 using a commercially available "spectral domain" OCT device (3D OCT-1000, Topcon. Images were obtained using a raster scan protocol, 6 mm x 6 mm in area, and consisting of 128 B-scans. OCT image sets were stored on UK Biobank servers in a central repository, adjacent to high performance computers. Rapid, automated analysis of retinal thickness was performed using custom image segmentation software developed by the Topcon Advanced Biomedical Imaging Laboratory (TABIL. This software employs dual-scale gradient information to allow for automated segmentation of nine intraretinal boundaries in a rapid fashion.67,321 participants (134,642 eyes in UK Biobank underwent OCT imaging of both eyes as part of the ocular module. 134,611 images were successfully processed with 31 images failing segmentation analysis due to corrupted OCT files or withdrawal of subject consent for UKBB study participation. Average time taken to call up an image from the database and complete segmentation analysis was approximately 120 seconds per data set per login, and analysis of the entire dataset was completed in approximately 28 days.We report an approach to the rapid, automated measurement of retinal thickness from nearly 140,000 OCT image sets from the UK Biobank. In the near future, these measurements will be publically available for utilization by researchers around the world, and thus for correlation with the wealth of other data collected in UK Biobank. The automated analysis approaches we describe may be of utility for future large population-based epidemiological studies, clinical trials, and screening programs that employ OCT imaging.

  8. Sentiment Analysis in Geo Social Streams by using Machine Learning Techniques

    OpenAIRE

    Twanabasu, Bikesh

    2018-01-01

    Treball de Final de Màster Universitari Erasmus Mundus en Tecnologia Geoespacial (Pla de 2013). Codi: SIW013. Curs acadèmic 2017-2018 Massive amounts of sentiment rich data are generated on social media in the form of Tweets, status updates, blog post, reviews, etc. Different people and organizations are using these user generated content for decision making. Symbolic techniques or Knowledge base approaches and Machine learning techniques are two main techniques used for analysis sentiment...

  9. Noble Gas Measurement and Analysis Technique for Monitoring Reprocessing Facilities

    International Nuclear Information System (INIS)

    William S. Charlton

    1999-01-01

    An environmental monitoring technique using analysis of stable noble gas isotopic ratios on-stack at a reprocessing facility was developed. This technique integrates existing technologies to strengthen safeguards at reprocessing facilities. The isotopic ratios are measured using a mass spectrometry system and are compared to a database of calculated isotopic ratios using a Bayesian data analysis method to determine specific fuel parameters (e.g., burnup, fuel type, fuel age, etc.). These inferred parameters can be used by investigators to verify operator declarations. A user-friendly software application (named NOVA) was developed for the application of this technique. NOVA included a Visual Basic user interface coupling a Bayesian data analysis procedure to a reactor physics database (calculated using the Monteburns 3.01 code system). The integrated system (mass spectrometry, reactor modeling, and data analysis) was validated using on-stack measurements during the reprocessing of target fuel from a U.S. production reactor and gas samples from the processing of EBR-II fast breeder reactor driver fuel. These measurements led to an inferred burnup that matched the declared burnup with sufficient accuracy and consistency for most safeguards applications. The NOVA code was also tested using numerous light water reactor measurements from the literature. NOVA was capable of accurately determining spent fuel type, burnup, and fuel age for these experimental results. Work should continue to demonstrate the robustness of this system for production, power, and research reactor fuels

  10. Multiple predictor smoothing methods for sensitivity analysis: Description of techniques

    International Nuclear Information System (INIS)

    Storlie, Curtis B.; Helton, Jon C.

    2008-01-01

    The use of multiple predictor smoothing methods in sampling-based sensitivity analyses of complex models is investigated. Specifically, sensitivity analysis procedures based on smoothing methods employing the stepwise application of the following nonparametric regression techniques are described: (i) locally weighted regression (LOESS), (ii) additive models, (iii) projection pursuit regression, and (iv) recursive partitioning regression. Then, in the second and concluding part of this presentation, the indicated procedures are illustrated with both simple test problems and results from a performance assessment for a radioactive waste disposal facility (i.e., the Waste Isolation Pilot Plant). As shown by the example illustrations, the use of smoothing procedures based on nonparametric regression techniques can yield more informative sensitivity analysis results than can be obtained with more traditional sensitivity analysis procedures based on linear regression, rank regression or quadratic regression when nonlinear relationships between model inputs and model predictions are present

  11. Analysis of obsidians by PIXE technique

    International Nuclear Information System (INIS)

    Nuncio Q, A.E.

    1998-01-01

    This work presents the characterization of obsydian samples from different mineral sites in Mexico, undertaken by an Ion Beam Analysis: PIXE (Proton Induced X-ray Emission). As part of an intensive investigation of obsidian in Mesoamerica by anthropologists from Mexico National Institute of Anthropology and History, 818 samples were collected from different volcanic sources in central Mexico for the purpose of establishing a data bank of element concentrations of each source. Part of this collection was analyzed by Neutron activation analysis and most of the important elements concentrations reported. In this work, a non-destructive IBA technique (PIXE) are used to analyze obsydian samples. The application of this technique were carried out at laboratories of the ININ Nuclear Center facilities. The samples consisted of of obsydians from ten different volcanic sources. This pieces were mounted on a sample holder designed for the purpose of exposing each sample to the proton beam. This PIXE analysis was carried out with an ET Tandem Accelerator at the ININ. X-ray spectrometry was carried out with an external beam facility employing a Si(Li) detector set at 52.5 degrees in relation to the target normal (parallel to the beam direction) and 4.2 cm away from the target center. A filter was set in front of the detector, to determine the best attenuation conditions to obtain most of the elements, taking into account that X-ray spectra from obsydians are dominated by intense major elements lines. Thus, a 28 μ m- thick aluminium foil absorber was selected and used to reduce the intensity of the major lines as well as pile-up effects. The mean proton energy was 2.62 MeV, and the beam profile was about 4 mm in diameter. As results were founded elemental concentrations of a set of samples from ten different sources: Altotonga (Veracruz), Penjamo (Guanajuato), Otumba (Mexico), Zinapecuaro (Michoacan), Ucareo (Michoacan), Tres Cabezas (Puebla), Sierra Navajas (Hidalgo), Zaragoza

  12. The composite sequential clustering technique for analysis of multispectral scanner data

    Science.gov (United States)

    Su, M. Y.

    1972-01-01

    The clustering technique consists of two parts: (1) a sequential statistical clustering which is essentially a sequential variance analysis, and (2) a generalized K-means clustering. In this composite clustering technique, the output of (1) is a set of initial clusters which are input to (2) for further improvement by an iterative scheme. This unsupervised composite technique was employed for automatic classification of two sets of remote multispectral earth resource observations. The classification accuracy by the unsupervised technique is found to be comparable to that by traditional supervised maximum likelihood classification techniques. The mathematical algorithms for the composite sequential clustering program and a detailed computer program description with job setup are given.

  13. Rapid analysis of carbohydrates in aqueous extracts and hydrolysates of biomass using a carbonate-modified anion-exchange column.

    Science.gov (United States)

    Sevcik, Richard S; Mowery, Richard A; Becker, Christopher; Chambliss, C Kevin

    2011-03-04

    Quantitative liquid-chromatography techniques used to characterize carbohydrates present in biomass samples can suffer from long analysis times, limited analyte resolution, poor stability, or a combination of these factors. The current manuscript details a novel procedure enabling resolution of glucose, xylose, arabinose, galactose, mannose, fructose, and sucrose via isocratic elution in less than 5 min. Equivalent conditions also enable analysis of cellobiose and maltose with a minimal increase in chromatographic run time (ca. 3 and 6 min, respectively). Noted chromatographic performance requires that a commercially available anion-exchange column be modified with carbonate prior to analysis. Analytical performance of a modified column was assessed over a 5-day period via repeated analyses of 4 samples, resulting from aqueous extraction or quantitative saccharification of a potential biofuel feedstock (i.e., corn stover or switchgrass). A simple solid phase extraction procedure was utilized to clean up each sample prior to analysis. Analytical accuracy of the extraction protocol was assessed by evaluation of matrix spike recoveries which typically ranged from 84% to 98%. The instrumental variability of measured concentrations in real samples over the 5-day period was generally less than 5% RSD for all detected analytes, independent of sample type. Finally, it is important to note that the modified column exhibited exceptional stability over approximately 800 injections of biofeedstock-based samples. These data demonstrate that a carbonate-modified anion-exchange column can be employed for rapid determination of carbohydrates in biomass samples of lignocellulosic origin. Copyright © 2011 Elsevier B.V. All rights reserved.

  14. Population estimation techniques for routing analysis

    International Nuclear Information System (INIS)

    Sathisan, S.K.; Chagari, A.K.

    1994-01-01

    A number of on-site and off-site factors affect the potential siting of a radioactive materials repository at Yucca Mountain, Nevada. Transportation related issues such route selection and design are among them. These involve evaluation of potential risks and impacts, including those related to population. Population characteristics (total population and density) are critical factors in the risk assessment, emergency preparedness and response planning, and ultimately in route designation. This paper presents an application of Geographic Information System (GIS) technology to facilitate such analyses. Specifically, techniques to estimate critical population information are presented. A case study using the highway network in Nevada is used to illustrate the analyses. TIGER coverages are used as the basis for population information at a block level. The data are then synthesized at tract, county and state levels of aggregation. Of particular interest are population estimates for various corridor widths along transport corridors -- ranging from 0.5 miles to 20 miles in this paper. A sensitivity analysis based on the level of data aggregation is also presented. The results of these analysis indicate that specific characteristics of the area and its population could be used as indicators to aggregate data appropriately for the analysis

  15. The IDEAL (Integrated Design and Engineering Analysis Languages) modeling methodology: Capabilities and Applications

    Science.gov (United States)

    Evers, Ken H.; Bachert, Robert F.

    1987-01-01

    The IDEAL (Integrated Design and Engineering Analysis Languages) modeling methodology has been formulated and applied over a five-year period. It has proven to be a unique, integrated approach utilizing a top-down, structured technique to define and document the system of interest; a knowledge engineering technique to collect and organize system descriptive information; a rapid prototyping technique to perform preliminary system performance analysis; and a sophisticated simulation technique to perform in-depth system performance analysis.

  16. Analysis of pulse-shape discrimination techniques for BC501A using GHz digital signal processing

    International Nuclear Information System (INIS)

    Rooney, B.D.; Dinwiddie, D.R.; Nelson, M.A.; Rawool-Sullivan, Mohini W.

    2001-01-01

    A comparison study of pulse-shape analysis techniques was conducted for a BC501A scintillator using digital signal processing (DSP). In this study, output signals from a preamplifier were input directly into a 1 GHz analog-to-digital converter. The digitized data obtained with this method was post-processed for both pulse-height and pulse-shape information. Several different analysis techniques were evaluated for neutron and gamma-ray pulse-shape discrimination. It was surprising that one of the simplest and fastest techniques resulted in some of the best pulse-shape discrimination results. This technique, referred to here as the Integral Ratio technique, was able to effectively process several thousand detector pulses per second. This paper presents the results and findings of this study for various pulse-shape analysis techniques with digitized detector signals.

  17. Global Landslides on Rapidly Spinning Spheroids

    Science.gov (United States)

    Scheeres, Daniel J.; Sanchez, P.

    2013-10-01

    The angle of repose and conditions for global landslides on the surfaces of small, rapidly spinning, spheroidal asteroids are studied. Applying techniques of soil mechanics, we develop a theory for, and examples of, how regolith will fail and flow in this microgravity environment. Our motivation is to develop an understanding of the "top-shaped" class of asteroids based on analytical soil mechanics. Our analysis transforms the entire asteroid surface into a local frame where we can model it as a conventional granular pile with a surface slope, acceleration and height variations as a function of the body's spin rate, shape and density. A general finding is that the lowest point on a rapidly spinning spheroid is at the equator with the effective height of surface material monotonically increasing towards the polar regions, where the height can be larger than the physical radius of the body. We study the failure conditions of both cohesionless and cohesive regolith, and develop specific predictions of the surface profile as a function of the regolith angle of friction and the maximum spin rate experienced by the body. The theory also provides simple guidelines on what the shape may look like, although we do not analyze gravitationally self-consistent evolution of the body shape. The theory is tested with soft-sphere discrete element method granular mechanics simulations to better understand the dynamical aspects of global asteroid landslides. We find significant differences between failure conditions for cohesive and cohesionless regolith. In the case of cohesive regolith, we show that extremely small values of strength (much less than that found in lunar regolith) can stabilize a surface even at very rapid spin rates. Cohesionless surfaces, as expected, fail whenever their surface slopes exceed the angle of friction. Based on our analysis we propose that global landslides and the flow of material towards the equator on spheroidal bodies are precipitated by exogenous

  18. Automated Techniques for the Qualitative Analysis of Ecological Models: Continuous Models

    Directory of Open Access Journals (Sweden)

    Lynn van Coller

    1997-06-01

    Full Text Available The mathematics required for a detailed analysis of the behavior of a model can be formidable. In this paper, I demonstrate how various computer packages can aid qualitative analyses by implementing techniques from dynamical systems theory. Because computer software is used to obtain the results, the techniques can be used by nonmathematicians as well as mathematicians. In-depth analyses of complicated models that were previously very difficult to study can now be done. Because the paper is intended as an introduction to applying the techniques to ecological models, I have included an appendix describing some of the ideas and terminology. A second appendix shows how the techniques can be applied to a fairly simple predator-prey model and establishes the reliability of the computer software. The main body of the paper discusses a ratio-dependent model. The new techniques highlight some limitations of isocline analyses in this three-dimensional setting and show that the model is structurally unstable. Another appendix describes a larger model of a sheep-pasture-hyrax-lynx system. Dynamical systems techniques are compared with a traditional sensitivity analysis and are found to give more information. As a result, an incomplete relationship in the model is highlighted. I also discuss the resilience of these models to both parameter and population perturbations.

  19. Program for rapid dose assessment in criticality accident, RADAPAS

    International Nuclear Information System (INIS)

    Takahashi, Fumiaki

    2006-09-01

    In a criticality accident, a person near fissile material can receive extremely high dose which can cause acute health effect. For such a case, medical treatment should be carried out for the exposed person, according to severity of the exposure. Then, radiation dose should be rapidly assessed soon after an outbreak of an accident. Dose assessment based upon the quantity of induced 24 Na in human body through neutron exposure is expected as one of useful dosimetry techniques in a criticality accident. A dose assessment program, called RADAPAS (RApid Dose Assessment Program from Activated Sodium in Criticality Accidents), was therefore developed to assess rapidly radiation dose to exposed persons from activity of induced 24 Na. RADAPAS consists of two parts; one is a database part and the other is a part for execution of dose calculation. The database contains data compendiums of energy spectra and dose conversion coefficients from specific activity of 24 Na induced in human body, which had been derived in a previous analysis using Monte Carlo calculation code. Information for criticality configuration or characteristics of radiation in the accident field is to be interactively given with interface displays in the dose calculation. RADAPAS can rapidly derive radiation dose to the exposed person from the given information and measured 24 Na specific activity by using the conversion coefficient in database. This report describes data for dose conversions and dose calculation in RADAPAS and explains how to use the program. (author)

  20. A review of residual stress analysis using thermoelastic techniques

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, A F; Dulieu-Barton, J M; Quinn, S [University of Southampton, School of Engineering Sciences, Highfield, Southampton, SO17 1BJ (United Kingdom); Burguete, R L [Airbus UK Ltd., New Filton House, Filton, Bristol, BS99 7AR (United Kingdom)

    2009-08-01

    Thermoelastic Stress Analysis (TSA) is a full-field technique for experimental stress analysis that is based on infra-red thermography. The technique has proved to be extremely effective for studying elastic stress fields and is now well established. It is based on the measurement of the temperature change that occurs as a result of a stress change. As residual stress is essentially a mean stress it is accepted that the linear form of the TSA relationship cannot be used to evaluate residual stresses. However, there are situations where this linear relationship is not valid or departures in material properties due to manufacturing procedures have enabled evaluations of residual stresses. The purpose of this paper is to review the current status of using a TSA based approach for the evaluation of residual stresses and to provide some examples of where promising results have been obtained.

  1. A review of residual stress analysis using thermoelastic techniques

    International Nuclear Information System (INIS)

    Robinson, A F; Dulieu-Barton, J M; Quinn, S; Burguete, R L

    2009-01-01

    Thermoelastic Stress Analysis (TSA) is a full-field technique for experimental stress analysis that is based on infra-red thermography. The technique has proved to be extremely effective for studying elastic stress fields and is now well established. It is based on the measurement of the temperature change that occurs as a result of a stress change. As residual stress is essentially a mean stress it is accepted that the linear form of the TSA relationship cannot be used to evaluate residual stresses. However, there are situations where this linear relationship is not valid or departures in material properties due to manufacturing procedures have enabled evaluations of residual stresses. The purpose of this paper is to review the current status of using a TSA based approach for the evaluation of residual stresses and to provide some examples of where promising results have been obtained.

  2. Measurement of very rapidly variable temperatures

    International Nuclear Information System (INIS)

    Elberg, S.; Mathonnet, P.

    1974-01-01

    Bibliographical research and visits to laboratories were undertaken in order to survey the different techniques used to measure rapidly variable temperatures, specifying the limits in maximum temperature and variation rate (time constant). On the basis of the bibliographical study these techniques were classified in three categories according to the physical meaning of their response time. Extension of the bibliographical research to methods using fast temperature variation measurement techniques and visits to research and industrial laboratories gave in an idea of the problems raised by the application of these methods. The use of these techniques in fields other than those for which they were developed can sometimes be awkward in the case of thermometric probe devices where the time constant cannot generally be specified [fr

  3. Analysis and analytical techniques

    Energy Technology Data Exchange (ETDEWEB)

    Batuecas Rodriguez, T [Department of Chemistry and Isotopes, Junta de Energia Nuclear, Madrid (Spain)

    1967-01-01

    The technology associated with the use of organic coolants in nuclear reactors depends to a large extent on the determination and control of their physical and chemical properties, and particularly on the viability, speed, sensitivity, precision and accuracy (depending on the intended usage) of the methods employed in detection and analytical determination. This has led to the study and development of numerous techniques, some specially designed for the extreme conditions involved in working with the types of product in question and others adapted from existing techniques. In the specific case of polyphenyl and hydropolyphenyl mixtures, which have been the principal subjects of study to date and offer greatest promise, the analytical problems are broadly as follows: Composition of initial product or virgin coolant composition of macro components and amounts of organic and inorganic impurities; Coolant during and after operation. Determination of gases and organic compounds produced by pyrolysis and radiolysis (degradation and polymerization products); Control of systems for purifying and regenerating the coolant after use. Dissolved pressurization gases; Detection of intermediate products during decomposition; these are generally very unstable (free radicals); Degree of fouling and film formation. Tests to determine potential formation of films; Corrosion of structural elements and canning materials; Health and safety. Toxicity, inflammability and impurities that can be activated. Although some of the above problems are closely interrelated and entail similar techniques, they vary as to degree of difficulty. Another question is the difficulty of distinguishing clearly between techniques for determining physical and physico-chemical properties, on one hand, and analytical techniques on the other. Any classification is therefore somewhat arbitrary (for example, in the case of dosimetry and techniques for determining mean molecular weights or electrical conductivity

  4. Integration of novel low-cost colorimetric, laser photometric, and visual fluorescent techniques for rapid identification of falsified medicines in resource-poor areas: application to artemether-lumefantrine.

    Science.gov (United States)

    Green, Michael D; Hostetler, Dana M; Nettey, Henry; Swamidoss, Isabel; Ranieri, Nicola; Newton, Paul N

    2015-06-01

    The availability of falsified antimalarial drugs can be reduced with effective drug regulatory agencies and proper enforcement. Fundamental to these agencies taking action, rapid identification must be made as soon as they appear in the market place. Since falsified antimalarials occur mostly in developing countries, performing drug analysis presents itself with unique challenges. A fundamental factor in choosing a useful technique is affordability and simplicity. Therefore, we suggest a three-tiered drug evaluation strategy for identifying a falsified drug in resource-poor areas. Tier I is a simple comparison of a tablet's weight and dimensions with official specifications. Tier II uses inexpensive photometric devices (laser and fluorescence) to evaluate a tablet. Suspicious samples from Tier I and II assessments are then subjected to a colorimetric assay for active ingredients identification and quantification. In this article, we evaluate a novel colorimetric assay for the simultaneous assessment of both lumefantrine and artemether in co-formulated Coartem™ tablets, and integrate the method with two novel, low-cost, fluorescence and laser photometric devices. Image analysis software is used for the assessments. Although artemether-lumefantrine is used as an example, the strategy may be adapted to other medicines. © The American Society of Tropical Medicine and Hygiene.

  5. A microhistological technique for analysis of food habits of mycophagous rodents.

    Science.gov (United States)

    Patrick W. McIntire; Andrew B. Carey

    1989-01-01

    We present a technique, based on microhistological analysis of fecal pellets, for quantifying the diets of forest rodents. This technique provides for the simultaneous recording of fungal spores and vascular plant material. Fecal samples should be freeze dried, weighed, and rehydrated with distilled water. We recommend a minimum sampling intensity of 50 fields of view...

  6. Rapid thermal pulse annealing

    International Nuclear Information System (INIS)

    Miller, M.G.; Koehn, B.W.; Chaplin, R.L.

    1976-01-01

    Characteristics of recovery processes have been investigated for cases of heating a sample to successively higher temperatures by means of isochronal annealing or by using a rapid pulse annealing. A recovery spectra shows the same features independent of which annealing procedure is used. In order to determine which technique provides the best resolution, a study was made of how two independent first-order processes are separated for different heating rates and time increments of the annealing pulses. It is shown that the pulse anneal method offers definite advantages over isochronal annealing when annealing for short time increments. Experimental data by means of the pulse anneal techniques are given for the various substages of stage I of aluminium. (author)

  7. Rapid Prototyping in Orthopaedic Surgery: A User's Guide

    OpenAIRE

    Frame, Mark; Huntley, James S.

    2012-01-01

    Rapid prototyping (RP) is applicable to orthopaedic problems involving three dimensions, particularly fractures, deformities, and reconstruction. In the past, RP has been hampered by cost and difficulties accessing the appropriate expertise. Here we outline the history of rapid prototyping and furthermore a process using open-source software to produce a high fidelity physical model from CT data. This greatly mitigates the expense associated with the technique, allowing surgeons to produce pr...

  8. [Efficient and rapid non-test tube cloning of Jatropha curcas].

    Science.gov (United States)

    Wang, Zhao-Yu; Lin, Jing-Ming; Xu, Zeng-Fu

    2007-08-01

    To develop a new technique for efficient and rapid non-test tube cloning of the medicinal and energy- producing plant Jatropha curcas. Using the mini-stem fragment (2-3 cm) of Jatropha curcas with merely one axillary bud as the explant, the effect of an auxin IBA concentration on the plantlet regeneration was studied. When treated with 1 mg/LIBA for 1h, the explants showed the most rapid propagation. The mini-stem fragments high root regeneration ratio (96.7%), short root regeneration period (18.2-/+2.0 d), large number of new roots per explant (6.3-/+1.8), and long total root length (6.8-/+3.5 cm), demonstrating that this technique can be a simple and efficient method for rapid non-test tube cloning of Jatropha curcas of potential industrial value.

  9. Design and implementation of a rapid-mixer flow cell for time-resolved infrared microspectroscopy

    International Nuclear Information System (INIS)

    Marinkovic, Nebojsa S.; Adzic, Aleksandar R.; Sullivan, Michael; Kovacs, Kevin; Miller, Lisa M.; Rousseau, Denis L.; Yeh, Syun-Ru; Chance, Mark R.

    2000-01-01

    A rapid mixer for the analysis of reactions in the millisecond and submillisecond time domains by Fourier-transform infrared microspectroscopy has been constructed. The cell was tested by examination of cytochrome-c folding kinetics. The device allows collection of full infrared spectral data on millisecond and faster time scales subsequent to chemical jump reaction initiation. The data quality is sufficiently good such that spectral fitting techniques could be applied to analysis of the data. Thus, this method provides an advantage over kinetic measurements at single wavelengths using infrared laser or diode sources, particularly where band overlap exists

  10. An Analysis of Army Rapid Acquisition

    Science.gov (United States)

    2015-09-01

    measuring its bottom-line impacts enables managers to increase the productivity of these critical assets.”16 If we determine that the current rapid...readiness-requirements/. 111 William Beaver , “Mantech Awarded $61M for Contractor Logistics Sustainment Support Services,” Danger Zone Jobs (blog...could be quickly produced and fielded.”120  Stable and Available Funding. MRAP “was able to avoid negative cost and schedule impacts that are

  11. VLBI FOR GRAVITY PROBE B. IV. A NEW ASTROMETRIC ANALYSIS TECHNIQUE AND A COMPARISON WITH RESULTS FROM OTHER TECHNIQUES

    International Nuclear Information System (INIS)

    Lebach, D. E.; Ratner, M. I.; Shapiro, I. I.; Bartel, N.; Bietenholz, M. F.; Lederman, J. I.; Ransom, R. R.; Campbell, R. M.; Gordon, D.; Lestrade, J.-F.

    2012-01-01

    When very long baseline interferometry (VLBI) observations are used to determine the position or motion of a radio source relative to reference sources nearby on the sky, the astrometric information is usually obtained via (1) phase-referenced maps or (2) parametric model fits to measured fringe phases or multiband delays. In this paper, we describe a 'merged' analysis technique which combines some of the most important advantages of these other two approaches. In particular, our merged technique combines the superior model-correction capabilities of parametric model fits with the ability of phase-referenced maps to yield astrometric measurements of sources that are too weak to be used in parametric model fits. We compare the results from this merged technique with the results from phase-referenced maps and from parametric model fits in the analysis of astrometric VLBI observations of the radio-bright star IM Pegasi (HR 8703) and the radio source B2252+172 nearby on the sky. In these studies we use central-core components of radio sources 3C 454.3 and B2250+194 as our positional references. We obtain astrometric results for IM Peg with our merged technique even when the source is too weak to be used in parametric model fits, and we find that our merged technique yields astrometric results superior to the phase-referenced mapping technique. We used our merged technique to estimate the proper motion and other astrometric parameters of IM Peg in support of the NASA/Stanford Gravity Probe B mission.

  12. Quantitative analysis of topoisomerase IIα to rapidly evaluate cell proliferation in brain tumors

    International Nuclear Information System (INIS)

    Oda, Masashi; Arakawa, Yoshiki; Kano, Hideyuki; Kawabata, Yasuhiro; Katsuki, Takahisa; Shirahata, Mitsuaki; Ono, Makoto; Yamana, Norikazu; Hashimoto, Nobuo; Takahashi, Jun A.

    2005-01-01

    Immunohistochemical cell proliferation analyses have come into wide use for evaluation of tumor malignancy. Topoisomerase IIα (topo IIα), an essential nuclear enzyme, has been known to have cell cycle coupled expression. We here show the usefulness of quantitative analysis of topo IIα mRNA to rapidly evaluate cell proliferation in brain tumors. A protocol to quantify topo IIα mRNA was developed with a real-time RT-PCR. It took only 3 h to quantify from a specimen. A total of 28 brain tumors were analyzed, and the level of topo IIα mRNA was significantly correlated with its immuno-staining index (p < 0.0001, r = 0.9077). Furthermore, it sharply detected that topo IIα mRNA decreased in growth-inhibited glioma cell. These results support that topo IIα mRNA may be a good and rapid indicator to evaluate cell proliferate potential in brain tumors

  13. Rapid quantification of TBP and TBP degradation product ratios by FTIR-ATR

    International Nuclear Information System (INIS)

    Gillens, A.R.; Powell, B.A.; Clemson University, Clemson, SC

    2013-01-01

    Tri-n-butyl phosphate (TBP) is the key complexant within the plutonium and uranium reduction extraction process used to extract uranium and plutonium from used nuclear fuel. During reprocessing TBP degrades to dibutyl phosphate (DBP), butyl acid phosphate (MBP), butanol, and phosphoric acid over time. A method for rapidly monitoring TBP degradation is needed for the support of nuclear forensics. Therefore, a Fourier transform infrared spectrometry-attenuated total reflectance (FTIR-ATR) technique was developed to determine approximate peak intensity ratios of TBP and its degradation products. The technique was developed by combining variable concentrations of TBP, DBP, and MBP to simulate TBP degradation. This method is achieved by analyzing selected peak positions and peak intensity ratios of TBP and DBP at different stages of degradation. The developed technique was tested on TBP samples degraded with nitric acid. In mock degradation samples, the 1,235 cm -1 peak position shifts to 1,220 cm -1 as the concentration of TBP decreases and DBP increases. Peak intensity ratios of TBP positions at 1,279 and 1,020 cm -1 relative to DBP positions at 909 and 1,003 cm -1 demonstrate an increasing trend as the concentration of DBP increases. The same peak intensity ratios were used to analyze DBP relative to MBP whereas a decreasing trend is seen with increasing DBP concentrations. The technique developed from this study may be used as a tool to determine TBP degradation in nuclear reprocessing via a rapid FTIR-ATR measurement without gas chromatography analysis. (author)

  14. Rapid wide-field Mueller matrix polarimetry imaging based on four photoelastic modulators with no moving parts.

    Science.gov (United States)

    Alali, Sanaz; Gribble, Adam; Vitkin, I Alex

    2016-03-01

    A new polarimetry method is demonstrated to image the entire Mueller matrix of a turbid sample using four photoelastic modulators (PEMs) and a charge coupled device (CCD) camera, with no moving parts. Accurate wide-field imaging is enabled with a field-programmable gate array (FPGA) optical gating technique and an evolutionary algorithm (EA) that optimizes imaging times. This technique accurately and rapidly measured the Mueller matrices of air, polarization elements, and turbid phantoms. The system should prove advantageous for Mueller matrix analysis of turbid samples (e.g., biological tissues) over large fields of view, in less than a second.

  15. Rapid analysis of some rare earth magnets

    Energy Technology Data Exchange (ETDEWEB)

    Raoot, K N; Raoot, S; Rukmani Desikan, N [Defence Metallurgical Research Lab., Hyderabad (India)

    1978-12-01

    A simple complexometric method for the quick analysis of the constituent elements in some quaternary rare earth magnets of the type RE-Co-Cu-Fe and RE-Ni-Cu-Fe is described. The technique is based on a total titration, subsequent release of EDTA from rare earth with ammonium fluoride and that from copper (II) with ascorbic acid and thiourea followed by determination of the excess and liberated EDTA by lead nitrate in a weak acid medium using xylenol orange indicator. In another, aliquot iron (III) and rare earth are first masked with sodium fluoride, and copper (II) with ascorbic acid and thiourea before cobalt (II) or nickel (II) is estimated by back titration. Iron is calculated by difference. The new method yields accurate and reproducible results with error not exceeding 1%. A set of three samples can conveniently be analysed in two hours.

  16. Rapid analysis of some rare earth magnets

    International Nuclear Information System (INIS)

    Raoot, K.N.; Raoot, Sarala; Rukmani Desikan, N.

    1978-01-01

    A simple complexometric method for the quick analysis of the constituent elements in some quaternary rare earth magnets of the type RE-Co-Cu-Fe and RE-Ni-Cu-Fe is described. The technique is based on a total titration, subsequent release of EDTA from rare earth with ammonium fluoride and that from copper (II) with ascorbic acid and thiourea followed by determination of the excess and liberated EDTA by lead nitrate in a weak acid medium using xylenol orange indicator. In another, aliquot iron (III) and rare earth are first masked with sodium fluoride, and copper (II) with ascorbic acid and thiourea before cobalt (II) or nickel (II) is estimated by back titration. Iron is calculated by difference. The new method yields accurate and reproducible results with error not exceeding 1%. A set of three samples can conveniently be analysed in two hours. (author)

  17. Application of optimal estimation techniques to FFTF decay heat removal analysis

    International Nuclear Information System (INIS)

    Nutt, W.T.; Additon, S.L.; Parziale, E.A.

    1979-01-01

    The verification and adjustment of plant models for decay heat removal analysis using a mix of engineering judgment and formal techniques from control theory are discussed. The formal techniques facilitate dealing with typical test data which are noisy, redundant and do not measure all of the plant model state variables directly. Two pretest examples are presented. 5 refs

  18. Cost analysis and estimating tools and techniques

    CERN Document Server

    Nussbaum, Daniel

    1990-01-01

    Changes in production processes reflect the technological advances permeat­ ing our products and services. U. S. industry is modernizing and automating. In parallel, direct labor is fading as the primary cost driver while engineering and technology related cost elements loom ever larger. Traditional, labor-based ap­ proaches to estimating costs are losing their relevance. Old methods require aug­ mentation with new estimating tools and techniques that capture the emerging environment. This volume represents one of many responses to this challenge by the cost analysis profession. The Institute of Cost Analysis (lCA) is dedicated to improving the effective­ ness of cost and price analysis and enhancing the professional competence of its members. We encourage and promote exchange of research findings and appli­ cations between the academic community and cost professionals in industry and government. The 1990 National Meeting in Los Angeles, jointly spo~sored by ICA and the National Estimating Society (NES),...

  19. Burnout prediction using advance image analysis coal characterization techniques

    Energy Technology Data Exchange (ETDEWEB)

    Edward Lester; Dave Watts; Michael Cloke [University of Nottingham, Nottingham (United Kingdom). School of Chemical Environmental and Mining Engineering

    2003-07-01

    The link between petrographic composition and burnout has been investigated previously by the authors. However, these predictions were based on 'bulk' properties of the coal, including the proportion of each maceral or the reflectance of the macerals in the whole sample. Combustion studies relating burnout with microlithotype analysis, or similar, remain less common partly because the technique is more complex than maceral analysis. Despite this, it is likely that any burnout prediction based on petrographic characteristics will become more accurate if it includes information about the maceral associations and the size of each particle. Chars from 13 coals, 106-125 micron size fractions, were prepared using a Drop Tube Furnace (DTF) at 1300{degree}C and 200 millisecond and 1% Oxygen. These chars were then refired in the DTF at 1300{degree}C 5% oxygen and residence times of 200, 400 and 600 milliseconds. The progressive burnout of each char was compared with the characteristics of the initial coals. This paper presents an extension of previous studies in that it relates combustion behaviour to coals that have been characterized on a particle by particle basis using advanced image analysis techniques. 13 refs., 7 figs.

  20. Analysis on Big Data Problems and Technique Supports of Archives Informatization

    Directory of Open Access Journals (Sweden)

    Du Xiaoyan

    2017-06-01

    Full Text Available [Purpose/significance] The realistic questions of the archives informatization management are faced with data size rapidly increasing, and their types and structures more diverse and complex. [Method/process] Based on the essential attribute of archives in this paper, the big data characteristics of digital archives in their storage and utilization links were analyzed, and the support of new big data techniques in the course of archives informatization, and their applications to the storage and utilization of digital archives and knowledge discovery were researched. [Result/conclusion] Modern processing technology for big data would not only bring certain supports for the management of archives informatization, but also promote the development of its theory and practice.

  1. Artificial Intelligence techniques for big data analysis

    OpenAIRE

    Aditya Khatri

    2017-01-01

    During my stay in Salamanca (Spain), I was fortunate enough to participate in the BISITE Research Group of the University of Salamanca. The University of Salamanca is the oldest university in Spain and in 2018 it celebrates its 8th centenary. As a computer science researcher, I participated in one of the many international projects that the research group has active, especially in big data analysis using Artificial Intelligence (AI) techniques. AI is one of BISITE's main lines of rese...

  2. Techniques to extract physical modes in model-independent analysis of rings

    International Nuclear Information System (INIS)

    Wang, C.-X.

    2004-01-01

    A basic goal of Model-Independent Analysis is to extract the physical modes underlying the beam histories collected at a large number of beam position monitors so that beam dynamics and machine properties can be deduced independent of specific machine models. Here we discuss techniques to achieve this goal, especially the Principal Component Analysis and the Independent Component Analysis.

  3. Review of sample preparation techniques for the analysis of pesticide residues in soil.

    Science.gov (United States)

    Tadeo, José L; Pérez, Rosa Ana; Albero, Beatriz; García-Valcárcel, Ana I; Sánchez-Brunete, Consuelo

    2012-01-01

    This paper reviews the sample preparation techniques used for the analysis of pesticides in soil. The present status and recent advances made during the last 5 years in these methods are discussed. The analysis of pesticide residues in soil requires the extraction of analytes from this matrix, followed by a cleanup procedure, when necessary, prior to their instrumental determination. The optimization of sample preparation is a very important part of the method development that can reduce the analysis time, the amount of solvent, and the size of samples. This review considers all aspects of sample preparation, including extraction and cleanup. Classical extraction techniques, such as shaking, Soxhlet, and ultrasonic-assisted extraction, and modern techniques like pressurized liquid extraction, microwave-assisted extraction, solid-phase microextraction and QuEChERS (Quick, Easy, Cheap, Effective, Rugged, and Safe) are reviewed. The different cleanup strategies applied for the purification of soil extracts are also discussed. In addition, the application of these techniques to environmental studies is considered.

  4. Comparative study of macrotexture analysis using X-ray diffraction and electron backscattered diffraction techniques

    International Nuclear Information System (INIS)

    Serna, Marilene Morelli

    2002-01-01

    The macrotexture is one of the main characteristics in metallic materials, which the physical properties depend on the crystallographic direction. The analysis of the macrotexture to middles of the decade of 80 was just accomplished by the techniques of Xray diffraction and neutrons diffraction. The possibility of the analysis of the macrotexture using, the technique of electron backscattering diffraction in the scanning electronic microscope, that allowed to correlate the measure of the orientation with its location in the micro structure, was a very welcome tool in the area of engineering of materials. In this work it was studied the theoretical aspects of the two techniques and it was used of both techniques for the analysis of the macrotexture of aluminum sheets 1050 and 3003 with intensity, measured through the texture index 'J', from 2.00 to 5.00. The results obtained by the two techniques were shown reasonably similar, being considered that the statistics of the data obtained by the technique of electron backscatter diffraction is much inferior to the obtained by the X-ray diffraction. (author)

  5. Multivariate analysis of remote LIBS spectra using partial least squares, principal component analysis, and related techniques

    Energy Technology Data Exchange (ETDEWEB)

    Clegg, Samuel M [Los Alamos National Laboratory; Barefield, James E [Los Alamos National Laboratory; Wiens, Roger C [Los Alamos National Laboratory; Sklute, Elizabeth [MT HOLYOKE COLLEGE; Dyare, Melinda D [MT HOLYOKE COLLEGE

    2008-01-01

    Quantitative analysis with LIBS traditionally employs calibration curves that are complicated by the chemical matrix effects. These chemical matrix effects influence the LIBS plasma and the ratio of elemental composition to elemental emission line intensity. Consequently, LIBS calibration typically requires a priori knowledge of the unknown, in order for a series of calibration standards similar to the unknown to be employed. In this paper, three new Multivariate Analysis (MV A) techniques are employed to analyze the LIBS spectra of 18 disparate igneous and highly-metamorphosed rock samples. Partial Least Squares (PLS) analysis is used to generate a calibration model from which unknown samples can be analyzed. Principal Components Analysis (PCA) and Soft Independent Modeling of Class Analogy (SIMCA) are employed to generate a model and predict the rock type of the samples. These MV A techniques appear to exploit the matrix effects associated with the chemistries of these 18 samples.

  6. A restricted access material for rapid analysis of [(11)C]-labeled radiopharmaceuticals and their metabolites in plasma

    DEFF Research Database (Denmark)

    Gillings, N.

    2009-01-01

    , combined with a monolithic analysis column in a column-switching HPLC system. RESULTS: Up to 4 ml of plasma was analyzed by this method within 4.5-7 min in a fully automated process. Because of the rapid analysis, a large number of samples could be analyzed during a 90-min PET scan. The extraction column...

  7. Image-analysis techniques for investigation localized corrosion processes

    International Nuclear Information System (INIS)

    Quinn, M.J.; Bailey, M.G.; Ikeda, B.M.; Shoesmith, D.W.

    1993-12-01

    We have developed a procedure for determining the mode and depth of penetration of localized corrosion by combining metallography and image analysis of corroded coupons. Two techniques, involving either a face-profiling or an edge-profiling procedure, have been developed. In the face-profiling procedure, successive surface grindings and image analyses were performed until corrosion was no longer visible. In this manner, the distribution of corroded sites on the surface and the total area of the surface corroded were determined as a function of depth into the specimen. In the edge-profiling procedure, surface grinding exposed successive cross sections of the corroded region. Image analysis of the cross section quantified the distribution of depths across the corroded section, and a three-dimensional distribution of penetration depths was obtained. To develop these procedures, we used artificially creviced Grade-2 titanium specimens that were corroded in saline solutions containing various amounts of chloride maintained at various fixed temperatures (105 to 150 degrees C) using a previously developed galvanic-coupling technique. We discuss some results from these experiments to illustrate how the procedures developed can be applied to a real corroded system. (author). 6 refs., 4 tabs., 21 figs

  8. Potential applications of rapid/elementary nonparametric statistical techniques (NST) to electrochemical problems

    International Nuclear Information System (INIS)

    Fahidy, Thomas Z.

    2009-01-01

    A major advantage of NST lies in the unimportance of the probability distribution of observations. In this paper, the sign test, the rank-sum test, the Kruskal-Wallis test, the Friedman test, and the runs test illustrate the potential of certain rapid NST for the evaluation of electrochemical process performance.

  9. Performance evaluation using bootstrapping DEA techniques: Evidence from industry ratio analysis

    OpenAIRE

    Halkos, George; Tzeremes, Nickolaos

    2010-01-01

    In Data Envelopment Analysis (DEA) context financial data/ ratios have been used in order to produce a unified measure of performance metric. However, several scholars have indicated that the inclusion of financial ratios create biased efficiency estimates with implications on firms’ and industries’ performance evaluation. There have been several DEA formulations and techniques dealing with this problem including sensitivity analysis, Prior-Ratio-Analysis and DEA/ output–input ratio analysis ...

  10. The financial impact of the incorporation of IMRT and RapidArc™ techniques on shielding calculation of a linear accelerator; O impacto financeiro da incorporacao das tecnicas de IMRT e RapidArc™ no calculo de blindagem de um acelerador linear

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Maira R.; Silveira, Thiago B.; Garcia, Paulo L.; Trindade, Cassia; Martins, Lais P.; Batista, Delano V.S., E-mail: mairafisica@gmail.com [Instituto Nacional do Cancer (INCA), Rio de Janeiro, RJ (Brazil)

    2013-08-15

    Given the new methodology introduced in the shielding calculation due to recent modulated techniques in radiotherapy treatment, it became necessary to evaluate the impact of changes in the accelerator routine using such techniques. Based on a group of 30 patients from the National Cancer Institute (INCA) the workload multiplier factors for intensity modulated radiotherapy (IMRT factor) and for RapidArc™ (RA factor) were established. Four different routines in a 6 MV generic accelerator were proposed to estimate the impact of these modified workloads in the building cost of the secondary barriers. The results indicate that if 50% of patients are treating with IMRT, the secondary barrier becomes 14,1% more expensive than the barrier calculated for conformal treatments exclusive. While RA, in the same proportion, leads to a barrier only 3,7% more expensive. Showing that RA can, while reducing treatment time, increase the proportion of patients treated with modulation technique, without increasing the cost of the barrier, when compared with IMRT. (author)

  11. Rapid prototyping using robot welding : process description

    OpenAIRE

    Ribeiro, António Fernando; Norrish, John

    1997-01-01

    Rapid Prototyping is a relatively recent technique to produce component prototypes for industry in a much shorter period of time, since the time to market a product is essential to its success. A new Rapid Prototyping process which uses metal as the raw material had been under development at Cranfield University in the last few years. The process uses a Gas Metal Arc fusion welding robot which deposits successive layers of metal in such way that it forms a 3D solid component. Firstly, a CAD s...

  12. Pesticide residues in canned foods, fruits, and vegetables: the application of Supercritical Fluid Extraction and chromatographic techniques in the analysis.

    Science.gov (United States)

    El-Saeid, Mohamed H

    2003-12-11

    Multiple pesticide residues have been observed in some samples of canned foods, frozen vegetables, and fruit jam, which put the health of the consumers at risk of adverse effects. It is quite apparent that such a state of affairs calls for the need of more accurate, cost-effective, and rapid analytical techniques capable of detecting the minimum concentrations of the multiple pesticide residues. The aims of this paper were first, to determine the effectiveness of the use of Supercritical Fluid Extraction (SFE) and Supercritical Fluid Chromatography (SFC) techniques in the analysis of the levels of pesticide residues in canned foods, vegetables, and fruits; and second, to contribute to the promotion of consumer safety by excluding pesticide residue contamination from markets. Fifteen different types of imported canned and frozen fruits and vegetables samples obtained from the Houston local food markets were investigated. The major types of pesticides tested were pyrethroids, herbicides, fungicides, and carbamates. By using these techniques, the overall data showed 60.82% of the food samples had no detection of any pesticide residues under this investigation. On the other hand, 39.15% different food samples were contaminated by four different pyrethroid residues +/- RSD% ranging from 0.03 +/- 0.005 to 0.05 +/- 0.03 ppm, of which most of the pyrethroid residues were detected in frozen vegetables and strawberry jam. Herbicide residues in test samples ranged from 0.03 +/- 0.005 to 0.8 +/- 0.01 ppm. Five different fungicides, ranging from 0.05 +/- 0.02 to 0.8 +/- 0.1 ppm, were found in five different frozen vegetable samples. Carbamate residues were not detected in 60% of investigated food samples. It was concluded that SFE and SFC techniques were accurate, reliable, less time consuming, and cost effective in the analysis of imported canned foods, fruits, and vegetables and are recommended for the monitoring of pesticide contaminations.

  13. Analysis and Comparison of the Antioxidant Component of Portulaca Oleracea Leaves Obtained by Different Solid-Liquid Extraction Techniques

    Science.gov (United States)

    Conte, Esterina

    2017-01-01

    Portulaca oleracea is a wild plant pest of orchards and gardens, but is also an edible vegetable rich in beneficial nutrients. It possesses many antioxidant properties due to the high content of vitamins, minerals, omega-3 essential fatty acids and other healthful compounds; therefore, the intake of purslane and/or its bioactive compounds could help to improve the health and function of the whole human organism. Accordingly, in this work it was analyzed and compared to the extractive capacity of the antioxidant component of purslane leaves obtained by solid-liquid extraction techniques such as: hot-maceration, maceration with ultrasound, rapid solid-liquid dynamic extraction using the Naviglio extractor, and a combination of two techniques (mix extraction). The chromatographic analysis by High Performance Liquid Chromatography (HPLC) of the methanolic extract of dried purslane leaves allowed the identification of various polyphenolic compounds for comparison with the standards. In addition, the properties of the different extracts were calculated on dry matter and the antioxidant properties of the total polyphenol components analyzed by the DPPH (2,2-diphenyl-1-picrylhydrazyl) assay. The results showed that mix extraction was the most efficient compared to other techniques. In fact, it obtained a quantity of polyphenols amounting to 237.8 mg Gallic Acid Equivalents (GAE)/100 g of fresh weight, while in other techniques, the range varied from 60–160 mg GAE/100 g fresh weight. In addition, a qualitative analysis by Liquid Chromatography-Tandem Mass Spectrometry (LC/MS/MS) of the phenolic compounds present in the purslane leaves examined was carried out. The compounds were identified by comparison of their molecular weight, fragmentation pattern and retention time with those of standards, using the “Multiple Reaction Monitoring” mode (MRM). Therefore, this study allowed the re-evaluation of a little-known plant that possesses as its beneficial properties, a

  14. Analysis of the Rapid Chloride Migration test

    NARCIS (Netherlands)

    Spiesz, P.R.; Ballari, M.; Brouwers, H.J.H.; Ferreira, R. M.; Gulikers, J.; Andrade, C.

    2009-01-01

    In this study the Rapid Chloride Migration test (RCM) standardized as NT Build 492 and BAW-Merkblatt is reviewed. Since the traditional natural diffusion tests are laborious, time consuming and costly, they are not always preferred from a practical point of view. To overcome these disadvantages,

  15. Recent developments in fast spectroscopy for plant mineral analysis

    Directory of Open Access Journals (Sweden)

    Marie evan Maarschalkerweerd

    2015-03-01

    Full Text Available Ideal fertilizer management to optimize plant productivity and quality is more relevant than ever, as global food demands increase along with the rapidly growing world population. At the same time, sub-optimal or excessive use of fertilizers leads to severe environmental damage in areas of intensive crop production. The approaches of soil and plant mineral analysis are briefly compared and discussed here, and the new techniques using fast spectroscopy that offer cheap, rapid and easy-to-use analysis of plant nutritional status are reviewed. The majority of these methods use vibrational spectroscopy, such as Visual-Near Infrared (Vis-NIR and to a lesser extent Ultraviolet (UV and Mid-Infrared (MIR spectroscopy. Advantages of and problems with application of these techniques are thoroughly discussed. Spectroscopic techniques considered having major potential for plant mineral analysis, such as chlorophyll a fluorescence, X-ray fluorescence (XRF and Laser-Induced Breakdown Spectroscopy (LIBS are also described.

  16. Interferogram analysis using the Abel inversion technique

    International Nuclear Information System (INIS)

    Yusof Munajat; Mohamad Kadim Suaidi

    2000-01-01

    High speed and high resolution optical detection system were used to capture the image of acoustic waves propagation. The freeze image in the form of interferogram was analysed to calculate the transient pressure profile of the acoustic waves. The interferogram analysis was based on the fringe shift and the application of the Abel inversion technique. An easier approach was made by mean of using MathCAD program as a tool in the programming; yet powerful enough to make such calculation, plotting and transfer of file. (Author)

  17. Analysis of fresh fallout from Chinese tests by beta counting technique

    International Nuclear Information System (INIS)

    Mishra, U.C.; Lalit, B.Y.; Shukla, V.K.; Ramachandran, T.V.

    1979-01-01

    The paper describes beta counting techniques used in the analysis of fresh radioactive fallout samples from nuclear weapon tests. Fresh fallout samples have been collected by swiping the exposed portion of the engine covers of commercial aircrafts arriving at Bombay from New York after Chinese tests on September 26, 1976 and September 17, 1977. Activities of short-lived radionuclides such as Ag 111, Sr 89, Mo 99, U 237 and Np 239 were determined using these techniques. The results obtained from this analysis is discussed in brief in relation to the kind of fissile material, the extent of thermonuclear reaction in the weapon and the mode of detonation. (orig.) [de

  18. Skull reconstruction after resection of bone tumors in a single surgical time by the association of the techniques of rapid prototyping and surgical navigation.

    Science.gov (United States)

    Anchieta, M V M; Salles, F A; Cassaro, B D; Quaresma, M M; Santos, B F O

    2016-10-01

    Presentation of a new cranioplasty technique employing a combination of two technologies: rapid prototyping and surgical navigation. This technique allows the reconstruction of the skull cap after the resection of a bone tumor in a single surgical time. The neurosurgeon plans the craniotomy previously on the EximiusMed software, compatible with the Eximius Surgical Navigator, both from the company Artis Tecnologia (Brazil). The navigator imports the planning and guides the surgeon during the craniotomy. The simulation of the bone fault allows the virtual reconstruction of the skull cap and the production of a personalized modelling mold using the Magics-Materialise (Belgium)-software. The mold and a replica of the bone fault are made by rapid prototyping by the company Artis Tecnologia (Brazil) and shipped under sterile conditions to the surgical center. The PMMA prosthesis is produced during the surgical act with the help of a hand press. The total time necessary for the planning and production of the modelling mold is four days. The precision of the mold is submillimetric and accurately reproduces the virtual reconstruction of the prosthesis. The production of the prosthesis during surgery takes until twenty minutes depending on the type of PMMA used. The modelling mold avoids contraction and dissipates the heat generated by the material's exothermic reaction in the polymerization phase. The craniectomy is performed with precision over the drawing made with the help of the Eximius Surgical Navigator, according to the planned measurements. The replica of the bone fault serves to evaluate the adaptation of the prosthesis as a support for the perforations and the placement of screws and fixation plates, as per the surgeon's discretion. This technique allows the adequate oncologic treatment associated with a satisfactory aesthetic result, with precision, in a single surgical time, reducing time and costs.

  19. Use of rapid sampling microdialysis for intraoperative monitoring of bowel ischemia.

    Science.gov (United States)

    Deeba, S; Corcoles, E P; Hanna, G B; Hanna, B G; Pareskevas, P; Aziz, O; Boutelle, M G; Darzi, A

    2008-09-01

    Intestinal ischemia is a major cause of anastomotic leak and death and remains a clinical challenge as the physician relies on several nonspecific signs, biologic markers, and radiologic studies to make the diagnosis. This study used rapid sampling online microdialysis to evaluate the biochemical changes occurring in a segment of human bowel during and after resection, and assessed for the feasibility and reproducibility of this technique in monitoring intestinal ischemia. A custom made, rapid sampling online microdialysis analyzer was used to monitor the changes in the bowel wall of specimens being resected intraoperatively. Two patients were recruited for the pilot study to optimize the analyzer and seven patients undergoing colonic resections were recruited for the data collection and analysis. The concentration of glucose in the extracellular bowel wall fluid decreased transiently after division of individual feeding arteries followed by a rebound increase in the concentration back to baseline concentrations. After completion of resection, glucose concentrations continued to decrease while lactate concentrations increased constantly. Rapid sampling microdialysis was feasible in the clinical environment. These results suggest that tissue responds to ischemic insult by mobilizing glucose stores which later decrease again, whereas lactate concentrations constantly increased.

  20. Spatial Analysis for Potential Water Catchment Areas using GIS: Weighted Overlay Technique

    Science.gov (United States)

    Awanda, Disyacitta; Anugrah Nurul, H.; Musfiroh, Zahrotul; Dinda Dwi, N. P.

    2017-12-01

    The development of applied GIS is growing rapidly and has been widely applied in various fields. Preparation of a model to obtain information is one of the benefits of GIS. Obtaining information for water resources such as water catchment areas is one part of GIS modelling. Water catchment model can be utilized to see the distribution of potential and ability of a region in water absorbing. The use of overlay techniques with the weighting obtained from the literature from previous research is used to build the model. Model builder parameters are obtained through remote sensing interpretation techniques such as land use, landforms, and soil texture. Secondary data such as rock type maps are also used as water catchment model parameters. The location of this research is in the upstream part of the Opak river basin. The purpose of this research is to get information about potential distribution of water catchment area with overlay technique. The results of this study indicate the potential of water catchment areas with excellent category, good, medium, poor and very poor. These results may indicate that the Upper river basin is either good or in bad condition, so it can be used for better water resources management policy determination.

  1. Cost-effective and rapid blood analysis on a cell-phone.

    Science.gov (United States)

    Zhu, Hongying; Sencan, Ikbal; Wong, Justin; Dimitrov, Stoyan; Tseng, Derek; Nagashima, Keita; Ozcan, Aydogan

    2013-04-07

    We demonstrate a compact and cost-effective imaging cytometry platform installed on a cell-phone for the measurement of the density of red and white blood cells as well as hemoglobin concentration in human blood samples. Fluorescent and bright-field images of blood samples are captured using separate optical attachments to the cell-phone and are rapidly processed through a custom-developed smart application running on the phone for counting of blood cells and determining hemoglobin density. We evaluated the performance of this cell-phone based blood analysis platform using anonymous human blood samples and achieved comparable results to a standard bench-top hematology analyser. Test results can either be stored on the cell-phone memory or be transmitted to a central server, providing remote diagnosis opportunities even in field settings.

  2. A Comparative Analysis of Uranium Ore using Laser Fluorimetric and gamma Spectrometry Techniques

    International Nuclear Information System (INIS)

    Madbouly, M.; Nassef, M. H.; El-Mongy, S.A.; Diab, A.M.

    2009-01-01

    A developed chemical separation method was used for the analysis of uranium in a standard U-ore (IAEA-RGU-1) by LASER fluorimetric technique. The non-destructive gamma assay technique was also applied to verify and compare the uranium content analyzed using laser technique. The results of the uranium analysis obtained by laser fluorimetry were found to be in the range of 360 - 420 μg/g with an average value of 390 μg/g. The bias between the measured and the certified value does not exceed 9.9%. For gamma-ray spectrometric analysis, the results of the measured uranium content were found to be in the range of 393.8 - 399.4 μg/g with an average value of 396.3 μg/g. The % difference in the case of γ- assay was 1.6 %. In general, the methods of analysis used in this study are applicable for a precise determination of uranium. It can be concluded that, laser analysis is preferred for assay of uranium ore due to the required small sample weight, the low time of sample preparation and cost of analysis.

  3. Rapid Prototyping Technologies and their Applications in Prosthodontics, a Review of Literature.

    Science.gov (United States)

    Torabi, Kianoosh; Farjood, Ehsan; Hamedani, Shahram

    2015-03-01

    The early computer-aided design/computer-aided manufacturing (CAD/CAM) systems were relied exclusively on subtractive methods. In recent years, additive methods by employing rapid prototyping (RP) have progressed rapidly in various fields of dentistry as they have the potential to overcome known drawbacks of subtractive techniques such as fit problems. RP techniques have been exploited to build complex 3D models in medicine since the 1990s. RP has recently proposed successful applications in various dental fields, such as fabrication of implant surgical guides, frameworks for fixed and removable partial dentures, wax patterns for the dental prosthesis, zirconia prosthesis and molds for metal castings, and maxillofacial prosthesis and finally, complete dentures. This paper aimed to offer a comprehensive literature review of various RP methods, particularly in dentistry, that are expected to bring many improvements to the field. A search was made through MEDLINE database and Google scholar search engine. The keywords; 'rapid prototyping' and 'dentistry' were searched in title/abstract of publications; limited to 2003 to 2013, concerning past decade. The inclusion criterion was the technical researches that predominately included laboratory procedures. The exclusion criterion was meticulous clinical and excessive technical procedures. A total of 106 articles were retrieved, recited by authors and only 50 met the specified inclusion criteria for this review. Selected articles had used rapid prototyping techniques in various fields in dentistry through different techniques. This review depicted the different laboratory procedures employed in this method and confirmed that RP technique have been substantially feasible in dentistry. With advancement in various RP systems, it is possible to benefit from this technique in different dental practices, particularly in implementing dental prostheses for different applications.

  4. [A new method of fabricating photoelastic model by rapid prototyping].

    Science.gov (United States)

    Fan, Li; Huang, Qing-feng; Zhang, Fu-qiang; Xia, Yin-pei

    2011-10-01

    To explore a novel method of fabricating the photoelastic model using rapid prototyping technique. A mandible model was made by rapid prototyping with computerized three-dimensional reconstruction, then the photoelastic model with teeth was fabricated by traditional impression duplicating and mould casting. The photoelastic model of mandible with teeth, which was fabricated indirectly by rapid prototyping, was very similar to the prototype in geometry and physical parameters. The model was of high optical sensibility and met the experimental requirements. Photoelastic model of mandible with teeth indirectly fabricated by rapid prototyping meets the photoelastic experimental requirements well.

  5. Fault tree technique: advances in probabilistic and logical analysis

    International Nuclear Information System (INIS)

    Clarotti, C.A.; Amendola, A.; Contini, S.; Squellati, G.

    1982-01-01

    Fault tree reliability analysis is used for assessing the risk associated to systems of increasing complexity (phased mission systems, systems with multistate components, systems with non-monotonic structure functions). Much care must be taken to make sure that fault tree technique is not used beyond its correct validity range. To this end a critical review of mathematical foundations of reliability fault tree analysis is carried out. Limitations are enlightened and potential solutions to open problems are suggested. Moreover an overview is given on the most recent developments in the implementation of an integrated software (SALP-MP, SALP-NOT, SALP-CAFT Codes) for the analysis of a wide class of systems

  6. A field technique for rapid lithological discrimination and ore mineral ...

    Indian Academy of Sciences (India)

    weighted spectral similarity and effective peak matching techniques were used to draw end-members from library. ...... D A 2006 A mobile tram system for systematic sampling .... Rogers A D and Christensen P R 2007 Surface mineralogy of.

  7. Rapid determination of fluorine in coral skeletons by non-destructive neutron activation analysis using 20F

    International Nuclear Information System (INIS)

    Ramos, A.A.; Ohde, S.; Sirirattanachai, S.; Snidvongs, A.

    2003-01-01

    A rapid non-destructive technique has been proposed for the determination of fluorine in coral skeletons by thermal neutron activation analysis, using the short half-life 20 F nuclide (11.0 s). About 0.2-0.5 g samples were irradiated for 10 seconds in a Triga Mark II Reactor. Soon after the irradiation (25-35 s), measurements of γ-rays were performed with each sample and standard. The method has the drawback of low sensitivity (∼20 ppm of F), and the manual operation employed in the cooling step could lead to less precise measurements. Fluorine in coral standards was determined within ∼8% of analytical precision. The result obtained for the dolomite standard was fairly consistent with literature values, but those for the limestone standard showed to be considerably higher than the reported values. The present method was applied for the determination of fluorine in modern corals from Khang Khao Island, Thailand and Okinawa, Japan. Two core samples of an ancient reef from Funafuti Atoll were measured for fluorine to compare with modern samples. In order to understand the environmental media in which coral grew, the partition of fluorine between seawater and coral skeletons is also discussed. (author)

  8. Sensitivity analysis techniques applied to a system of hyperbolic conservation laws

    International Nuclear Information System (INIS)

    Weirs, V. Gregory; Kamm, James R.; Swiler, Laura P.; Tarantola, Stefano; Ratto, Marco; Adams, Brian M.; Rider, William J.; Eldred, Michael S.

    2012-01-01

    Sensitivity analysis is comprised of techniques to quantify the effects of the input variables on a set of outputs. In particular, sensitivity indices can be used to infer which input parameters most significantly affect the results of a computational model. With continually increasing computing power, sensitivity analysis has become an important technique by which to understand the behavior of large-scale computer simulations. Many sensitivity analysis methods rely on sampling from distributions of the inputs. Such sampling-based methods can be computationally expensive, requiring many evaluations of the simulation; in this case, the Sobol' method provides an easy and accurate way to compute variance-based measures, provided a sufficient number of model evaluations are available. As an alternative, meta-modeling approaches have been devised to approximate the response surface and estimate various measures of sensitivity. In this work, we consider a variety of sensitivity analysis methods, including different sampling strategies, different meta-models, and different ways of evaluating variance-based sensitivity indices. The problem we consider is the 1-D Riemann problem. By a careful choice of inputs, discontinuous solutions are obtained, leading to discontinuous response surfaces; such surfaces can be particularly problematic for meta-modeling approaches. The goal of this study is to compare the estimated sensitivity indices with exact values and to evaluate the convergence of these estimates with increasing samples sizes and under an increasing number of meta-model evaluations. - Highlights: ► Sensitivity analysis techniques for a model shock physics problem are compared. ► The model problem and the sensitivity analysis problem have exact solutions. ► Subtle details of the method for computing sensitivity indices can affect the results.

  9. Rapid analysis of vessel elements (RAVE: a tool for studying physiologic, pathologic and tumor angiogenesis.

    Directory of Open Access Journals (Sweden)

    Marc E Seaman

    Full Text Available Quantification of microvascular network structure is important in a myriad of emerging research fields including microvessel remodeling in response to ischemia and drug therapy, tumor angiogenesis, and retinopathy. To mitigate analyst-specific variation in measurements and to ensure that measurements represent actual changes in vessel network structure and morphology, a reliable and automatic tool for quantifying microvascular network architecture is needed. Moreover, an analysis tool capable of acquiring and processing large data sets will facilitate advanced computational analysis and simulation of microvascular growth and remodeling processes and enable more high throughput discovery. To this end, we have produced an automatic and rapid vessel detection and quantification system using a MATLAB graphical user interface (GUI that vastly reduces time spent on analysis and greatly increases repeatability. Analysis yields numerical measures of vessel volume fraction, vessel length density, fractal dimension (a measure of tortuosity, and radii of murine vascular networks. Because our GUI is open sourced to all, it can be easily modified to measure parameters such as percent coverage of non-endothelial cells, number of loops in a vascular bed, amount of perfusion and two-dimensional branch angle. Importantly, the GUI is compatible with standard fluorescent staining and imaging protocols, but also has utility analyzing brightfield vascular images, obtained, for example, in dorsal skinfold chambers. A manually measured image can be typically completed in 20 minutes to 1 hour. In stark comparison, using our GUI, image analysis time is reduced to around 1 minute. This drastic reduction in analysis time coupled with increased repeatability makes this tool valuable for all vessel research especially those requiring rapid and reproducible results, such as anti-angiogenic drug screening.

  10. Rapid assay of plutonium in soils by passive L x-ray counting

    International Nuclear Information System (INIS)

    Gehrke, R.J.; Putnam, M.H.; Goodwin, S.G.; Kynaston, R.L.

    1992-05-01

    A technique has been developed to rapidly measure the presence of plutonium in soils, filters, smears, and glass waste forms by measuring the uranium L-shell x-ray emissions associated with the decay of plutonium. In addition, the technique can simultaneously acquire spectra of samples and automatically analyze them for the amount of americium, and gamma-ray emitting activation and fission products present. The samples are counted with a large area, thin-window, n-type Ge spectrometer which is equally efficient for the detection of low energy x-rays (>10 key), as well as high-energy gamma rays (>1 MeV). A 8192-channel analyzer is used to acquire the entire photon spectrum at one time. A dual-energy, time-tagged pulser, that is injected into the test input of the preamplifier to monitor the energy scale, detector resolution, and pulse pile-up will be installed in FY-92. The L x-ray portion of each spectrum is analyzed by a linear least-squares spectral fitting technique originally developed for the analysis of spectra from NaI(Tl) detectors. The gamma-ray portion of each spectrum is analyzed by a standard Ge gamma-ray analysis package. Detection limits (also referred to as lower limits of detection) for plutonium in contaminated soils that have been achieved by this technique are reported

  11. Novel technique for coal pyrolysis and hydrogenation production analysis

    Energy Technology Data Exchange (ETDEWEB)

    Pfefferle, L.D.

    1990-01-01

    The overall objective of this study is to establish vacuum ultraviolet photoionization-MS and VUV pulsed EI-MS as useful tools for a simpler and more accurate direct mass spectrometric measurement of a broad range of hydrocarbon compounds in complex mixtures for ultimate application to the study of the kinetics of coal hydrogenation and pyrolysis processes. The VUV-MS technique allows ionization of a broad range of species with minimal fragmentation. Many compounds of interest can be detected with the 118 nm wavelength, but additional compound selectivity is achievable by tuning the wavelength of the photo-ionization source in the VUV. Resonant four wave mixing techniques in Hg vapor will allow near continuous tuning from about 126 to 106 nm. This technique would facilitate the scientific investigation of coal upgrading processes such as pyrolysis and hydrogenation by allowing accurate direct analysis of both stable and intermediate reaction products.

  12. Study on the experimental VHTR safety with analysis for a hypothetical rapid depressurization accident

    International Nuclear Information System (INIS)

    Mitake, S.; Suzuki, K.; Ohno, T.; Okada, T.

    1982-01-01

    A hypothetical rapid depressurization accident of the experimental VHTR has been analyzed, including all phenomena in the accident, from its initiating depressurization of the coolant to consequential radiological hazard. Based on reliability analysis of the engineered safety features, all possible sequences, in which the safety systems are in success or in failure, have been investigated with event tree analysis. The result shows the inherent safety characteristics of the reactor and the effectiveness of the engineered safety features. And through the analysis, it has been indicated that further investigations on some phenomena in the accident, e.g., air ingress by natural circulation flow and fission product transport in the plant, will bring forth more reasonable and sufficient safety of the reactor

  13. Rapid Diagnosis of Bacterial Meningitis Using a Microarray

    Directory of Open Access Journals (Sweden)

    Ren-Jy Ben

    2008-06-01

    Conclusion: The microarray method provides a more accurate and rapid diagnostic tool for bacterial meningitis compared to traditional culture methods. Clinical application of this new technique may reduce the potential risk of delay in treatment.

  14. SU-E-T-393: Evaluation of Large Field IMRT Versus RapidArc Planning for Carcinoma Cervix with Para-Aotic Node Irradiation

    International Nuclear Information System (INIS)

    Raman, S Kothanda; Girigesh, Y; MISHRA, M; Lalit, K

    2015-01-01

    Purpose: The objective of this work is to evaluate and compare Large field IMRT and RapidArc planning for Carcinoma Cervix and Para-aotic node irradiation. Methods: In this study, ten patients of Cervix with para-aotic node have been selected with PTV length 35+2cm. All plans were generated in Eclipse TPS V10.0 with Dynamic IMRT and RapidArc technique using 6MV photon energy. In IMRT planning, 7 fields were chosen to get optimal plan and in RapidArc, double Full arc clockwise and counter clockwise were used for planning. All the plans were generated with single isocenter and calculated using AAA dose algorithm. For all the cases the prescribed dose to PTV was same and the plan acceptance criteria is; 95% of the PTV volume should receive 100% prescribed dose. The tolerance doses for the OAR’s is also taken in to account. The evaluation criteria used for analysis are; 1) Homogeneity Index, 2) Conformity Index, 3) Mean Dose to OAR’s, 4)Total monitor units delivered. Results: DVH analysis were performed for both IMRT and RapidArc planning. In both the plans, 95% of PTV volume receives prescribed dose and maximum dose are less than 107%. The conformity index are same in both the techniques. The mean Homogeneity index are 1.036 and 1.053 for IMRT and RapidArc plan. The mean (mean + SD) dose of bladder and rectum in IMRT is 44.2+1.55, 42.05+2.52 and RapidArc is 46.66+1.6, 44.2+2.75 respectively. There is no significant difference found in Right Femoral head, Left Femoral head and Kidney doses. It is found that total MU’s are more in IMRT compared with RapidArc planning. Conclusion: In the case of cervix with Para-arotic node single isocenter irradiation, IMRT planning in large-field is better compared to RapidArc planning in terms of Homogeneity Index and mean dose of Bladder and Rectum

  15. SU-E-T-393: Evaluation of Large Field IMRT Versus RapidArc Planning for Carcinoma Cervix with Para-Aotic Node Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Raman, S Kothanda; Girigesh, Y; MISHRA, M; Lalit, K [Rajiv Gandhi Cancer Institute & Research Centre, New Delhi (India)

    2015-06-15

    Purpose: The objective of this work is to evaluate and compare Large field IMRT and RapidArc planning for Carcinoma Cervix and Para-aotic node irradiation. Methods: In this study, ten patients of Cervix with para-aotic node have been selected with PTV length 35+2cm. All plans were generated in Eclipse TPS V10.0 with Dynamic IMRT and RapidArc technique using 6MV photon energy. In IMRT planning, 7 fields were chosen to get optimal plan and in RapidArc, double Full arc clockwise and counter clockwise were used for planning. All the plans were generated with single isocenter and calculated using AAA dose algorithm. For all the cases the prescribed dose to PTV was same and the plan acceptance criteria is; 95% of the PTV volume should receive 100% prescribed dose. The tolerance doses for the OAR’s is also taken in to account. The evaluation criteria used for analysis are; 1) Homogeneity Index, 2) Conformity Index, 3) Mean Dose to OAR’s, 4)Total monitor units delivered. Results: DVH analysis were performed for both IMRT and RapidArc planning. In both the plans, 95% of PTV volume receives prescribed dose and maximum dose are less than 107%. The conformity index are same in both the techniques. The mean Homogeneity index are 1.036 and 1.053 for IMRT and RapidArc plan. The mean (mean + SD) dose of bladder and rectum in IMRT is 44.2+1.55, 42.05+2.52 and RapidArc is 46.66+1.6, 44.2+2.75 respectively. There is no significant difference found in Right Femoral head, Left Femoral head and Kidney doses. It is found that total MU’s are more in IMRT compared with RapidArc planning. Conclusion: In the case of cervix with Para-arotic node single isocenter irradiation, IMRT planning in large-field is better compared to RapidArc planning in terms of Homogeneity Index and mean dose of Bladder and Rectum.

  16. Breath Analysis Using Laser Spectroscopic Techniques: Breath Biomarkers, Spectral Fingerprints, and Detection Limits

    Directory of Open Access Journals (Sweden)

    Peeyush Sahay

    2009-10-01

    Full Text Available Breath analysis, a promising new field of medicine and medical instrumentation, potentially offers noninvasive, real-time, and point-of-care (POC disease diagnostics and metabolic status monitoring. Numerous breath biomarkers have been detected and quantified so far by using the GC-MS technique. Recent advances in laser spectroscopic techniques and laser sources have driven breath analysis to new heights, moving from laboratory research to commercial reality. Laser spectroscopic detection techniques not only have high-sensitivity and high-selectivity, as equivalently offered by the MS-based techniques, but also have the advantageous features of near real-time response, low instrument costs, and POC function. Of the approximately 35 established breath biomarkers, such as acetone, ammonia, carbon dioxide, ethane, methane, and nitric oxide, 14 species in exhaled human breath have been analyzed by high-sensitivity laser spectroscopic techniques, namely, tunable diode laser absorption spectroscopy (TDLAS, cavity ringdown spectroscopy (CRDS, integrated cavity output spectroscopy (ICOS, cavity enhanced absorption spectroscopy (CEAS, cavity leak-out spectroscopy (CALOS, photoacoustic spectroscopy (PAS, quartz-enhanced photoacoustic spectroscopy (QEPAS, and optical frequency comb cavity-enhanced absorption spectroscopy (OFC-CEAS. Spectral fingerprints of the measured biomarkers span from the UV to the mid-IR spectral regions and the detection limits achieved by the laser techniques range from parts per million to parts per billion levels. Sensors using the laser spectroscopic techniques for a few breath biomarkers, e.g., carbon dioxide, nitric oxide, etc. are commercially available. This review presents an update on the latest developments in laser-based breath analysis.

  17. Scanning angle Raman spectroscopy: Investigation of Raman scatter enhancement techniques for chemical analysis

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, Matthew W. [Iowa State Univ., Ames, IA (United States)

    2013-01-01

    This thesis outlines advancements in Raman scatter enhancement techniques by applying evanescent fields, standing-waves (waveguides) and surface enhancements to increase the generated mean square electric field, which is directly related to the intensity of Raman scattering. These techniques are accomplished by employing scanning angle Raman spectroscopy and surface enhanced Raman spectroscopy. A 1064 nm multichannel Raman spectrometer is discussed for chemical analysis of lignin. Extending dispersive multichannel Raman spectroscopy to 1064 nm reduces the fluorescence interference that can mask the weaker Raman scattering. Overall, these techniques help address the major obstacles in Raman spectroscopy for chemical analysis, which include the inherently weak Raman cross section and susceptibility to fluorescence interference.

  18. Bienzymatic Biosensor for Rapid Detection of Aspartame by Flow Injection Analysis

    Directory of Open Access Journals (Sweden)

    Maria-Cristina Radulescu

    2014-01-01

    Full Text Available A rapid, simple and stable biosensor for aspartame detection was developed. Alcohol oxidase (AOX, carboxyl esterase (CaE and bovine serum albumin (BSA were immobilised with glutaraldehyde (GA onto screen-printed electrodes modified with cobalt-phthalocyanine (CoPC. The biosensor response was fast. The sample throughput using a flow injection analysis (FIA system was 40 h−1 with an RSD of 2.7%. The detection limits for both batch and FIA measurements were 0.1 µM for methanol and 0.2 µM for aspartame, respectively. The enzymatic biosensor was successfully applied for aspartame determination in different sample matrices/commercial products (liquid and solid samples without any pre-treatment step prior to measurement.

  19. Bienzymatic biosensor for rapid detection of aspartame by flow injection analysis.

    Science.gov (United States)

    Radulescu, Maria-Cristina; Bucur, Bogdan; Bucur, Madalina-Petruta; Radu, Gabriel Lucian

    2014-01-09

    A rapid, simple and stable biosensor for aspartame detection was developed. Alcohol oxidase (AOX), carboxyl esterase (CaE) and bovine serum albumin (BSA) were immobilised with glutaraldehyde (GA) onto screen-printed electrodes modified with cobalt-phthalocyanine (CoPC). The biosensor response was fast. The sample throughput using a flow injection analysis (FIA) system was 40 h⁻¹ with an RSD of 2.7%. The detection limits for both batch and FIA measurements were 0.1 µM for methanol and 0.2 µM for aspartame, respectively. The enzymatic biosensor was successfully applied for aspartame determination in different sample matrices/commercial products (liquid and solid samples) without any pre-treatment step prior to measurement.

  20. Comparison of Spares Logistics Analysis Techniques for Long Duration Human Spaceflight

    Science.gov (United States)

    Owens, Andrew; de Weck, Olivier; Mattfeld, Bryan; Stromgren, Chel; Cirillo, William

    2015-01-01

    As the durations and distances involved in human exploration missions increase, the logistics associated with the repair and maintenance becomes more challenging. Whereas the operation of the International Space Station (ISS) depends upon regular resupply from the Earth, this paradigm may not be feasible for future missions. Longer mission durations result in higher probabilities of component failures as well as higher uncertainty regarding which components may fail, and longer distances from Earth increase the cost of resupply as well as the speed at which the crew can abort to Earth in the event of an emergency. As such, mission development efforts must take into account the logistics requirements associated with maintenance and spares. Accurate prediction of the spare parts demand for a given mission plan and how that demand changes as a result of changes to the system architecture enables full consideration of the lifecycle cost associated with different options. In this paper, we utilize a range of analysis techniques - Monte Carlo, semi-Markov, binomial, and heuristic - to examine the relationship between the mass of spares and probability of loss of function related to the Carbon Dioxide Removal System (CRS) for a notional, simplified mission profile. The Exploration Maintainability Analysis Tool (EMAT), developed at NASA Langley Research Center, is utilized for the Monte Carlo analysis. We discuss the implications of these results and the features and drawbacks of each method. In particular, we identify the limitations of heuristic methods for logistics analysis, and the additional insights provided by more in-depth techniques. We discuss the potential impact of system complexity on each technique, as well as their respective abilities to examine dynamic events. This work is the first step in an effort that will quantitatively examine how well these techniques handle increasingly more complex systems by gradually expanding the system boundary.