WorldWideScience

Sample records for rapid accurate preliminary

  1. Accurate reconstruction of discontinuous mandible using a reverse engineering/computer-aided design/rapid prototyping technique: a preliminary clinical study.

    Science.gov (United States)

    Zhou, Li-bin; Shang, Hong-tao; He, Li-sheng; Bo, Bin; Liu, Gui-cai; Liu, Yan-pu; Zhao, Jin-long

    2010-09-01

    To improve the reconstructive surgical outcome of a discontinuous mandibular defect, we used reverse engineering (RE), computer-aided design (CAD), and rapid prototyping (RP) technique to fabricate customized mandibular trays to precisely restore the mandibular defects. Autogenous bone grafting was also used to restore the bony continuity for occlusion rehabilitation. Six patients who had undergone block resection of the mandible underwent reconstruction using a custom titanium tray combining autogenous iliac grafts. The custom titanium tray was made using a RE/CAD/RP technique. A virtual 3-dimensional model was obtained by spiral computed tomography scanning. The opposite side of the mandible was mirrored to cover the defect area to restore excellent facial symmetry. A bone grafting tray was designed from the mirrored image and manufactured using RP processing and casting. The mandibular defects were restored using the trays in combination of autologous iliac grafting. An implant denture was made for 1 of the 6 patients at 24 weeks postoperatively for occlusion rehabilitation. The trays fabricated using this technique fit well in all 6 patients. The reconstructive procedures were easy and time saving. Satisfactory facial symmetry was restored. No severe complications occurred in the 5 patients without occlusion rehabilitation during a mean 50-month follow-up period. The reconstruction in the patient with occlusion lasted for only 1 year and failed eventually because of bone resorption and infection. Mandibular reconstruction was facilitated using the RE/CAD/RP technique. Satisfactory esthetic results were achieved. However, the rigidity of the cast tray could cause severe stress shielding to the grafts, which could lead to disuse atrophy. Therefore, some modification is needed for functional reconstruction. Copyright 2010 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  2. Rapid and accurate pyrosequencing of angiosperm plastid genomes

    Directory of Open Access Journals (Sweden)

    Farmerie William G

    2006-08-01

    Full Text Available Abstract Background Plastid genome sequence information is vital to several disciplines in plant biology, including phylogenetics and molecular biology. The past five years have witnessed a dramatic increase in the number of completely sequenced plastid genomes, fuelled largely by advances in conventional Sanger sequencing technology. Here we report a further significant reduction in time and cost for plastid genome sequencing through the successful use of a newly available pyrosequencing platform, the Genome Sequencer 20 (GS 20 System (454 Life Sciences Corporation, to rapidly and accurately sequence the whole plastid genomes of the basal eudicot angiosperms Nandina domestica (Berberidaceae and Platanus occidentalis (Platanaceae. Results More than 99.75% of each plastid genome was simultaneously obtained during two GS 20 sequence runs, to an average depth of coverage of 24.6× in Nandina and 17.3× in Platanus. The Nandina and Platanus plastid genomes shared essentially identical gene complements and possessed the typical angiosperm plastid structure and gene arrangement. To assess the accuracy of the GS 20 sequence, over 45 kilobases of sequence were generated for each genome using conventional sequencing. Overall error rates of 0.043% and 0.031% were observed in GS 20 sequence for Nandina and Platanus, respectively. More than 97% of all observed errors were associated with homopolymer runs, with ~60% of all errors associated with homopolymer runs of 5 or more nucleotides and ~50% of all errors associated with regions of extensive homopolymer runs. No substitution errors were present in either genome. Error rates were generally higher in the single-copy and noncoding regions of both plastid genomes relative to the inverted repeat and coding regions. Conclusion Highly accurate and essentially complete sequence information was obtained for the Nandina and Platanus plastid genomes using the GS 20 System. More importantly, the high accuracy

  3. Improved method for rapid and accurate isolation and identification of Streptococcus mutans and Streptococcus sobrinus from human plaque samples.

    Science.gov (United States)

    Villhauer, Alissa L; Lynch, David J; Drake, David R

    2017-08-01

    Mutans streptococci (MS), specifically Streptococcus mutans (SM) and Streptococcus sobrinus (SS), are bacterial species frequently targeted for investigation due to their role in the etiology of dental caries. Differentiation of S. mutans and S. sobrinus is an essential part of exploring the role of these organisms in disease progression and the impact of the presence of either/both on a subject's caries experience. Of vital importance to the study of these organisms is an identification protocol that allows us to distinguish between the two species in an easy, accurate, and timely manner. While conducting a 5-year birth cohort study in a Northern Plains American Indian tribe, the need for a more rapid procedure for isolating and identifying high volumes of MS was recognized. We report here on the development of an accurate and rapid method for MS identification. Accuracy, ease of use, and material and time requirements for morphological differentiation on selective agar, biochemical tests, and various combinations of PCR primers were compared. The final protocol included preliminary identification based on colony morphology followed by PCR confirmation of species identification using primers targeting regions of the glucosyltransferase (gtf) genes of SM and SS. This method of isolation and identification was found to be highly accurate, more rapid than the previous methodology used, and easily learned. It resulted in more efficient use of both time and material resources. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Experiments in rapid development of accurate phonetic alignments for TTS in Afrikaans

    CSIR Research Space (South Africa)

    Van Niekerk, DR

    2011-11-01

    Full Text Available The quality of corpus-based text-to-speech (TTS) systems depends on the accuracy of phonetic annotation (alignments) which directly influences the process of acoustic modelling. In this paper the author discusses the rapid development of accurate...

  5. High performance liquid chromatography method for rapid and accurate determination of homocysteine in plasma and serum

    DEFF Research Database (Denmark)

    Vester, Birte; Rasmussen, K

    1991-01-01

    Determination of homocysteine in plasma or serum for evaluation of cobalamin and folate deficiency is becoming an important diagnostic procedure. Accurate, rapid and low cost methods for measuring homocysteine are therefore required. We have improved an HPLC method and made it suitable for clinical...

  6. Rapid identification of sequences for orphan enzymes to power accurate protein annotation.

    Directory of Open Access Journals (Sweden)

    Kevin R Ramkissoon

    Full Text Available The power of genome sequencing depends on the ability to understand what those genes and their proteins products actually do. The automated methods used to assign functions to putative proteins in newly sequenced organisms are limited by the size of our library of proteins with both known function and sequence. Unfortunately this library grows slowly, lagging well behind the rapid increase in novel protein sequences produced by modern genome sequencing methods. One potential source for rapidly expanding this functional library is the "back catalog" of enzymology--"orphan enzymes," those enzymes that have been characterized and yet lack any associated sequence. There are hundreds of orphan enzymes in the Enzyme Commission (EC database alone. In this study, we demonstrate how this orphan enzyme "back catalog" is a fertile source for rapidly advancing the state of protein annotation. Starting from three orphan enzyme samples, we applied mass-spectrometry based analysis and computational methods (including sequence similarity networks, sequence and structural alignments, and operon context analysis to rapidly identify the specific sequence for each orphan while avoiding the most time- and labor-intensive aspects of typical sequence identifications. We then used these three new sequences to more accurately predict the catalytic function of 385 previously uncharacterized or misannotated proteins. We expect that this kind of rapid sequence identification could be efficiently applied on a larger scale to make enzymology's "back catalog" another powerful tool to drive accurate genome annotation.

  7. Rapid Identification of Sequences for Orphan Enzymes to Power Accurate Protein Annotation

    Science.gov (United States)

    Ojha, Sunil; Watson, Douglas S.; Bomar, Martha G.; Galande, Amit K.; Shearer, Alexander G.

    2013-01-01

    The power of genome sequencing depends on the ability to understand what those genes and their proteins products actually do. The automated methods used to assign functions to putative proteins in newly sequenced organisms are limited by the size of our library of proteins with both known function and sequence. Unfortunately this library grows slowly, lagging well behind the rapid increase in novel protein sequences produced by modern genome sequencing methods. One potential source for rapidly expanding this functional library is the “back catalog” of enzymology – “orphan enzymes,” those enzymes that have been characterized and yet lack any associated sequence. There are hundreds of orphan enzymes in the Enzyme Commission (EC) database alone. In this study, we demonstrate how this orphan enzyme “back catalog” is a fertile source for rapidly advancing the state of protein annotation. Starting from three orphan enzyme samples, we applied mass-spectrometry based analysis and computational methods (including sequence similarity networks, sequence and structural alignments, and operon context analysis) to rapidly identify the specific sequence for each orphan while avoiding the most time- and labor-intensive aspects of typical sequence identifications. We then used these three new sequences to more accurately predict the catalytic function of 385 previously uncharacterized or misannotated proteins. We expect that this kind of rapid sequence identification could be efficiently applied on a larger scale to make enzymology’s “back catalog” another powerful tool to drive accurate genome annotation. PMID:24386392

  8. Research on the rapid and accurate positioning and orientation approach for land missile-launching vehicle.

    Science.gov (United States)

    Li, Kui; Wang, Lei; Lv, Yanhong; Gao, Pengyu; Song, Tianxiao

    2015-10-20

    Getting a land vehicle's accurate position, azimuth and attitude rapidly is significant for vehicle based weapons' combat effectiveness. In this paper, a new approach to acquire vehicle's accurate position and orientation is proposed. It uses biaxial optical detection platform (BODP) to aim at and lock in no less than three pre-set cooperative targets, whose accurate positions are measured beforehand. Then, it calculates the vehicle's accurate position, azimuth and attitudes by the rough position and orientation provided by vehicle based navigation systems and no less than three couples of azimuth and pitch angles measured by BODP. The proposed approach does not depend on Global Navigation Satellite System (GNSS), thus it is autonomous and difficult to interfere. Meanwhile, it only needs a rough position and orientation as algorithm's iterative initial value, consequently, it does not have high performance requirement for Inertial Navigation System (INS), odometer and other vehicle based navigation systems, even in high precise applications. This paper described the system's working procedure, presented theoretical deviation of the algorithm, and then verified its effectiveness through simulation and vehicle experiments. The simulation and experimental results indicate that the proposed approach can achieve positioning and orientation accuracy of 0.2 m and 20″ respectively in less than 3 min.

  9. Research on the Rapid and Accurate Positioning and Orientation Approach for Land Missile-Launching Vehicle

    Directory of Open Access Journals (Sweden)

    Kui Li

    2015-10-01

    Full Text Available Getting a land vehicle’s accurate position, azimuth and attitude rapidly is significant for vehicle based weapons’ combat effectiveness. In this paper, a new approach to acquire vehicle’s accurate position and orientation is proposed. It uses biaxial optical detection platform (BODP to aim at and lock in no less than three pre-set cooperative targets, whose accurate positions are measured beforehand. Then, it calculates the vehicle’s accurate position, azimuth and attitudes by the rough position and orientation provided by vehicle based navigation systems and no less than three couples of azimuth and pitch angles measured by BODP. The proposed approach does not depend on Global Navigation Satellite System (GNSS, thus it is autonomous and difficult to interfere. Meanwhile, it only needs a rough position and orientation as algorithm’s iterative initial value, consequently, it does not have high performance requirement for Inertial Navigation System (INS, odometer and other vehicle based navigation systems, even in high precise applications. This paper described the system’s working procedure, presented theoretical deviation of the algorithm, and then verified its effectiveness through simulation and vehicle experiments. The simulation and experimental results indicate that the proposed approach can achieve positioning and orientation accuracy of 0.2 m and 20″ respectively in less than 3 min.

  10. Development of a Fieldable, Rapid, Accurate and Sensitive Bio-Electronic, DNA Biosensor

    Science.gov (United States)

    2004-12-01

    single molecule of DNA or RNA and therefore does not require the use of PCR. The sensor chip can be engineered with an array of hundreds of independent test sites, which allows for confirmatory tests leading to a high level of specificity, the ability to screen for multiple threat agents simultaneously, and the capability to detect genetically engineered organisms. Biological agents continue to pose a major threat to U.S. troops as well as U.S. civilians both domestically and overseas. Rapid, accurate and sensitive detection and identification of biological agents is

  11. Rapid and accurate identification of microorganisms contaminating cosmetic products based on DNA sequence homology.

    Science.gov (United States)

    Fujita, Y; Shibayama, H; Suzuki, Y; Karita, S; Takamatsu, S

    2005-12-01

    The aim of this study was to develop rapid and accurate procedures to identify microorganisms contaminating cosmetic products, based on the identity of the nucleotide sequences of the internal transcribed spacer (ITS) region of the ribosomal RNA coding DNA (rDNA). Five types of microorganisms were isolated from the inner portion of lotion bottle caps, skin care lotions, and cleansing gels. The rDNA ITS region of microorganisms was amplified through the use of colony-direct PCR or ordinal PCR using DNA extracts as templates. The nucleotide sequences of the amplified DNA were determined and subjected to homology search of a publicly available DNA database. Thereby, we obtained DNA sequences possessing high similarity with the query sequences from the databases of all the five organisms analyzed. The traditional identification procedure requires expert skills, and a time period of approximately 1 month to identify the microorganisms. On the contrary, 3-7 days were sufficient to complete all the procedures employed in the current method, including isolation and cultivation of organisms, DNA sequencing, and the database homology search. Moreover, it was possible to develop the skills necessary to perform the molecular techniques required for the identification procedures within 1 week. Consequently, the current method is useful for rapid and accurate identification of microorganisms, contaminating cosmetics.

  12. Multifrequency excitation method for rapid and accurate dynamic test of micromachined gyroscope chips.

    Science.gov (United States)

    Deng, Yan; Zhou, Bin; Xing, Chao; Zhang, Rong

    2014-10-17

    A novel multifrequency excitation (MFE) method is proposed to realize rapid and accurate dynamic testing of micromachined gyroscope chips. Compared with the traditional sweep-frequency excitation (SFE) method, the computational time for testing one chip under four modes at a 1-Hz frequency resolution and 600-Hz bandwidth was dramatically reduced from 10 min to 6 s. A multifrequency signal with an equal amplitude and initial linear-phase-difference distribution was generated to ensure test repeatability and accuracy. The current test system based on LabVIEW using the SFE method was modified to use the MFE method without any hardware changes. The experimental results verified that the MFE method can be an ideal solution for large-scale dynamic testing of gyroscope chips and gyroscopes.

  13. Multifrequency Excitation Method for Rapid and Accurate Dynamic Test of Micromachined Gyroscope Chips

    Directory of Open Access Journals (Sweden)

    Yan Deng

    2014-10-01

    Full Text Available A novel multifrequency excitation (MFE method is proposed to realize rapid and accurate dynamic testing of micromachined gyroscope chips. Compared with the traditional sweep-frequency excitation (SFE method, the computational time for testing one chip under four modes at a 1-Hz frequency resolution and 600-Hz bandwidth was dramatically reduced from 10 min to 6 s. A multifrequency signal with an equal amplitude and initial linear-phase-difference distribution was generated to ensure test repeatability and accuracy. The current test system based on LabVIEW using the SFE method was modified to use the MFE method without any hardware changes. The experimental results verified that the MFE method can be an ideal solution for large-scale dynamic testing of gyroscope chips and gyroscopes.

  14. Easy Leaf Area: Automated Digital Image Analysis for Rapid and Accurate Measurement of Leaf Area

    Directory of Open Access Journals (Sweden)

    Hsien Ming Easlon

    2014-07-01

    Full Text Available Premise of the study: Measurement of leaf areas from digital photographs has traditionally required significant user input unless backgrounds are carefully masked. Easy Leaf Area was developed to batch process hundreds of Arabidopsis rosette images in minutes, removing background artifacts and saving results to a spreadsheet-ready CSV file. Methods and Results: Easy Leaf Area uses the color ratios of each pixel to distinguish leaves and calibration areas from their background and compares leaf pixel counts to a red calibration area to eliminate the need for camera distance calculations or manual ruler scale measurement that other software methods typically require. Leaf areas estimated by this software from images taken with a camera phone were more accurate than ImageJ estimates from flatbed scanner images. Conclusions: Easy Leaf Area provides an easy-to-use method for rapid measurement of leaf area and nondestructive estimation of canopy area from digital images.

  15. The preliminary exploration of 64-slice volume computed tomography in the accurate measurement of pleural effusion

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Zhi-Jun [Dept. of Radiology, North China Petroleum Bureau General Hospital, Renqiu, Hebei (China)], e-mail: Gzj3@163.com; Lin, Qiang [Dept. of Oncology, North China Petroleum Bureau General Hospital, Renqiu, Hebei (China); Liu, Hai-Tao [Dept. of General Surgery, North China Petroleum Bureau General Hospital, Renqiu, Hebei (China)] [and others])

    2013-09-15

    Background: Using computed tomography (CT) to rapidly and accurately quantify pleural effusion volume benefits medical and scientific research. However, the precise volume of pleural effusions still involves many challenges and currently does not have a recognized accurate measuring. Purpose: To explore the feasibility of using 64-slice CT volume-rendering technology to accurately measure pleural fluid volume and to then analyze the correlation between the volume of the free pleural effusion and the different diameters of the pleural effusion. Material and Methods: The 64-slice CT volume-rendering technique was used to measure and analyze three parts. First, the fluid volume of a self-made thoracic model was measured and compared with the actual injected volume. Second, the pleural effusion volume was measured before and after pleural fluid drainage in 25 patients, and the volume reduction was compared with the actual volume of the liquid extract. Finally, the free pleural effusion volume was measured in 26 patients to analyze the correlation between it and the diameter of the effusion, which was then used to calculate the regression equation. Results: After using the 64-slice CT volume-rendering technique to measure the fluid volume of the self-made thoracic model, the results were compared with the actual injection volume. No significant differences were found, P = 0.836. For the 25 patients with drained pleural effusions, the comparison of the reduction volume with the actual volume of the liquid extract revealed no significant differences, P = 0.989. The following linear regression equation was used to compare the pleural effusion volume (V) (measured by the CT volume-rendering technique) with the pleural effusion greatest depth (d): V = 158.16 X d - 116.01 (r = 0.91, P = 0.000). The following linear regression was used to compare the volume with the product of the pleural effusion diameters (l X h X d): V = 0.56 X (l X h X d) + 39.44 (r = 0.92, P = 0

  16. Rapid and accurate biofuel moisture content gauging using magnetic resonance measurement technology

    Energy Technology Data Exchange (ETDEWEB)

    Jaervinen, T.

    2013-04-15

    Biomass is extensively utilised in energy production and as a raw material, such as for the production of liquid biofuels. All those processes will benefit if the moisture content of bio material is known in advance as accurately as possible under transient circumstances. Biofuel trade is increasingly based on the calorific value of fuels. In the first step, this also increases the need for rapid and accurate moisture content determination. During the last few years, large biofuel standardisation has been implemented, emphasising biofuel quality control at all stages of the utilisation chain. In principle, the moisture instrumental measurement can be utilised by many technologies and procedures. Typical techniques are infrared, radiofrequency, microwave, radiometric, electrical conductivity, capacitance, and impedance. Nuclear magnetic resonance (MR) and thermal neutron absorption are also applied. The MR measurement principle has been known and utilised already since the early 1950s. It has become the basic instrumental analysis tool in chemistry. It is also well-known as a very accurate method for analysing most compounds, especially substances containing hydrogen. The utilisation of MR metering is expanded extensively to medical diagnostics as a form of magnetic resonance imaging (MRI). Because of the precision of the MR principle, there have for a long time been efforts to apply it in new and different areas, and to make more user-friendly, smaller, and even portable devices. Such a device was designed by Vaisala a few years ago. VTT has utilised Vaisala's MR prototype for approximately one year for moisture content measurement of different biofuels. The first step in the use of an MR device for moisture determination was the definition of its measurement accuracy compared to the standard method (EN 14774). Those tests proved that the absolute precision seems to be comparable to the standard moisture content measurement method. It was also found out that

  17. Optimal pcr primers for rapid and accurate detection of Aspergillus flavus isolates.

    Science.gov (United States)

    Al-Shuhaib, Mohammed Baqur S; Albakri, Ali H; Alwan, Sabah H; Almandil, Noor B; AbdulAzeez, Sayed; Borgio, J Francis

    2018-02-07

    Aspergillus flavus is among the most devastating opportunistic pathogens of several food crops including rice, due to its high production of carcinogenic aflatoxins. The presence of these organisms in economically important rice strip farming is a serious food safety concern. Several polymerase chain reaction (PCR) primers have been designed to detect this species; however, a comparative assessment of their accuracy has not been conducted. This study aims to identify the optimal diagnostic PCR primers for the identification of A. flavus, among widely available primers. We isolated 122 A. flavus native isolates from randomly collected rice strips (N = 300). We identified 109 isolates to the genus level using universal fungal PCR primer pairs. Nine pairs of primers were examined for their PCR diagnostic specificity on the 109 isolates. FLA PCR was found to be the optimal PCR primer pair for specific identification of the native isolates, over aflP(1), aflM, aflA, aflD, aflP(3), aflP(2), and aflR. The PEP primer pair was found to be the most unsuitable for A. flavus identification. In conclusion, the present study indicates the powerful specificity of the FLA PCR primer over other commonly available diagnostic primers for accurate, rapid, and large-scale identification of A. flavus native isolates. This study provides the first simple, practical comparative guide to PCR-based screening of A. flavus infection in rice strips. Copyright © 2018 Elsevier Ltd. All rights reserved.

  18. Rapid and accurate intraoperative pathological diagnosis by artificial intelligence with deep learning technology.

    Science.gov (United States)

    Zhang, Jing; Song, Yanlin; Xia, Fan; Zhu, Chenjing; Zhang, Yingying; Song, Wenpeng; Xu, Jianguo; Ma, Xuelei

    2017-09-01

    Frozen section is widely used for intraoperative pathological diagnosis (IOPD), which is essential for intraoperative decision making. However, frozen section suffers from some drawbacks, such as time consuming and high misdiagnosis rate. Recently, artificial intelligence (AI) with deep learning technology has shown bright future in medicine. We hypothesize that AI with deep learning technology could help IOPD, with a computer trained by a dataset of intraoperative lesion images. Evidences supporting our hypothesis included the successful use of AI with deep learning technology in diagnosing skin cancer, and the developed method of deep-learning algorithm. Large size of the training dataset is critical to increase the diagnostic accuracy. The performance of the trained machine could be tested by new images before clinical use. Real-time diagnosis, easy to use and potential high accuracy were the advantages of AI for IOPD. In sum, AI with deep learning technology is a promising method to help rapid and accurate IOPD. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. DNA Barcoding Coupled with High Resolution Melting Analysis Enables Rapid and Accurate Distinction of Aspergillus species.

    Science.gov (United States)

    Fidler, Gabor; Kocsube, Sandor; Leiter, Eva; Biro, Sandor; Paholcsek, Melinda

    2017-08-01

    We describe a high-resolution melting (HRM) analysis method that is rapid, reproducible, and able to identify reference strains and further 40 clinical isolates of Aspergillus fumigatus (14), A. lentulus (3), A. terreus (7), A. flavus (8), A. niger (2), A. welwitschiae (4), and A. tubingensis (2). Asp1 and Asp2 primer sets were designed to amplify partial sequences of the Aspergillus benA (beta-tubulin) genes in a closed-, single-tube system. Human placenta DNA, further Aspergillus (3), Candida (9), Fusarium (6), and Scedosporium (2) nucleic acids from type strains and clinical isolates were also included in this study to evaluate cross reactivity with other relevant pathogens causing invasive fungal infections. The barcoding capacity of this method proved to be 100% providing distinctive binomial scores; 14, 34, 36, 35, 25, 15, 26 when tested among species, while the within-species distinction capacity of the assay proved to be 0% based on the aligned thermodynamic profiles of the Asp1, Asp2 melting clusters allowing accurate species delimitation of all tested clinical isolates. The identification limit of this HRM assay was also estimated on Aspergillus reference gDNA panels where it proved to be 10-102 genomic equivalents (GE) except the A. fumigatus panel where it was 103 only. Furthermore, misidentification was not detected with human genomic DNA or with Candida, Fusarium, and Scedosporium strains. Our DNA barcoding assay introduced here provides results within a few hours, and it may possess further diagnostic utility when analyzing standard cultures supporting adequate therapeutic decisions. © The Author 2016. Published by Oxford University Press on behalf of The International Society for Human and Animal Mycology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  20. Development a rapid and accurate multiplex real time PCR method for the detection Chlamydia trachomatis and Mycoplasma hominis.

    Science.gov (United States)

    Safarkar, Roya; Mehrabadi, Jalil Fallah; Noormohammadi, Zahra; Mirnejad, Reza

    2017-11-01

    Sexually transmitted diseases easily spread among sexually active people and often have no symptoms. Rapid and accurate method for detecting these infections are necessary in early stages. The traditional detection methods of them are difficult and time-consuming. In this study, multiplex real time PCR was optimized for rapid identification of Chlamydia trachomatis and Mycoplasma hominis in a single tube and was performed with our designed primers. The sensitivity test was carried out to designed primers with diluted genomic DNA. To defined the specificity, non STD bacteria were used as DNA template. This study indicated that the developed multiplex real time PCR can be an effective alternative procedure to the conventional methods for rapid and accurate identification of C Chlamydia trachomatis and Mycoplasma hominis. Multiplex real-time PCR Results of them were checked with melting curves. The sensitivity of our designed primer by multiplex real time PCR for Chlamydia trachomatis and Mycoplasma hominis were 4.78×1010 and 8.35×1010 , respectively, Which the primers did not amplify any product from a non-STD species. Multiplex real time PCR by our new primers and analysis of melting curves were successfully usable for rapid and accurate detection of Chlamydia trachomatis and Mycoplasma hominis. This assay instead of traditional culture method, has considerable potential to be rapid, accurate and highly sensitive molecular diagnostic tool for simultaneous and direct detection. © 2017 Wiley Periodicals, Inc.

  1. Rapid, accurate, and comparative differentiation of clinically and industrially relevant microorganisms via multiple vibrational spectroscopic fingerprinting.

    Science.gov (United States)

    Muhamadali, Howbeer; Subaihi, Abdu; Mohammadtaheri, Mahsa; Xu, Yun; Ellis, David I; Ramanathan, Rajesh; Bansal, Vipul; Goodacre, Royston

    2016-08-15

    Despite the fact that various microorganisms (e.g., bacteria, fungi, viruses, etc.) have been linked with infectious diseases, their crucial role towards sustaining life on Earth is undeniable. The huge biodiversity, combined with the wide range of biochemical capabilities of these organisms, have always been the driving force behind their large number of current, and, as of yet, undiscovered future applications. The presence of such diversity could be said to expedite the need for the development of rapid, accurate and sensitive techniques which allow for the detection, differentiation, identification and classification of such organisms. In this study, we employed Fourier transform infrared (FT-IR), Raman, and surface enhanced Raman scattering (SERS) spectroscopies, as molecular whole-organism fingerprinting techniques, combined with multivariate statistical analysis approaches for the classification of a range of industrial, environmental or clinically relevant bacteria (P. aeruginosa, P. putida, E. coli, E. faecium, S. lividans, B. subtilis, B. cereus) and yeast (S. cerevisiae). Principal components-discriminant function analysis (PC-DFA) scores plots of the spectral data collected from all three techniques allowed for the clear differentiation of all the samples down to sub-species level. The partial least squares-discriminant analysis (PLS-DA) models generated using the SERS spectral data displayed lower accuracy (74.9%) when compared to those obtained from conventional Raman (97.8%) and FT-IR (96.2%) analyses. In addition, whilst background fluorescence was detected in Raman spectra for S. cerevisiae, this fluorescence was quenched when applying SERS to the same species, and conversely SERS appeared to introduce strong fluorescence when analysing P. putida. It is also worth noting that FT-IR analysis provided spectral data of high quality and reproducibility for the whole sample set, suggesting its applicability to a wider range of samples, and perhaps the

  2. Rapid Evaporative Ionisation Mass Spectrometry (REIMS) Provides Accurate Direct from Culture Species Identification within the Genus Candida.

    Science.gov (United States)

    Cameron, Simon J S; Bolt, Frances; Perdones-Montero, Alvaro; Rickards, Tony; Hardiman, Kate; Abdolrasouli, Alireza; Burke, Adam; Bodai, Zsolt; Karancsi, Tamas; Simon, Daniel; Schaffer, Richard; Rebec, Monica; Balog, Julia; Takáts, Zoltan

    2016-11-14

    Members of the genus Candida, such as C. albicans and C. parapsilosis, are important human pathogens. Other members of this genus, previously believed to carry minimal disease risk, are increasingly recognised as important human pathogens, particularly because of variations in susceptibilities to widely used anti-fungal agents. Thus, rapid and accurate identification of clinical Candida isolates is fundamental in ensuring timely and effective treatments are delivered. Rapid Evaporative Ionisation Mass Spectrometry (REIMS) has previously been shown to provide a high-throughput platform for the rapid and accurate identification of bacterial and fungal isolates. In comparison to commercially available matrix assisted laser desorption ionisation time of flight mass spectrometry (MALDI-ToF), REIMS based methods require no preparative steps nor time-consuming cell extractions. Here, we report on the ability of REIMS-based analysis to rapidly and accurately identify 153 clinical Candida isolates to species level. Both handheld bipolar REIMS and high-throughput REIMS platforms showed high levels of species classification accuracy, with 96% and 100% of isolates classified correctly to species level respectively. In addition, significantly different (FDR corrected P value < 0.05) lipids within the 600 to 1000 m/z mass range were identified, which could act as species-specific biomarkers in complex microbial communities.

  3. Collision-induced fragmentation accurate mass spectrometric analysis methods to rapidly characterize plant extracts

    Science.gov (United States)

    The rapid advances in analytical chromatography equipment have made the reliable and reproducible measurement of a wide range of plant chemical components possible. Full chemical characterization of a given plant material is possible with the new mass spectrometers currently available. For phytochem...

  4. Collision-induced fragmentation accurate mass spectrometric analysis methods to rapidly characterize phytochemicals in plant extracts

    Science.gov (United States)

    The rapid advances in analytical chromatography equipment have made the reliable and reproducible measurement of a wide range of plant chemical components possible. Full chemical characterization of a given plant material is possible with the new mass spectrometers currently available. New methods a...

  5. [Preliminary reports of noninvasive accurate method to measure pulmonary vascular capacity in normal volunteers].

    Science.gov (United States)

    Sun, Xing-guo; Mao, Song-shou; Budoff, M J; Stringer, W W; Cheng, Xian-sheng

    2015-07-01

    Because the traditional loop of breathing control and regulation effect on blood circulation, there was rare study of pulmonary vein capacity. We need a noninvasive and accurate pulmonary vascular capacity measurement and analysis method. Twelve normal volunteers were performed a total lung CT scan, image data analysis processing by computer software, the whole lungs from the apex to the base of lung with 40-50 layers by hand-cut, the connection between adjacent layers automatically by a computer simulation, the full pulmonary vascular (≥ 0.6 mm) were treated by high-accuracy three-dimensional imaging technology after removing the interference, and then calculate the whole lung and pulmonary vascular. The whole lung of the 12 normal volunteers from the apex to the base of lung CT scan image layers was 530 ± 98 (range, 431-841). The total capacity of lung and pulmonary vascular blood was 3705 ± 857 (range, 2398-5383) ml, and the total volume of the pulmonary vascular blood was 125 ± 32 (range, 94-201) ml. The pulmonary vein vascular blood volume was 63 ± 16 (range, 47-100) ml. The method of measuring the three-dimensional imaging of pulmonary vascular capacity by analyzing lung CT scan data is available and accurate.

  6. Preliminary evidence that DEXA provides an accurate assessment of body composition.

    Science.gov (United States)

    Kohrt, W M

    1998-01-01

    It was previously found that dual-energy X-ray absorptiometry (DEXA) underestimated central body fat. The purposes of this study were to determine whether an updated version (enhanced version 5.64) of the analysis program corrected this problem (experiment 1) and to compare body composition assessed by DEXA and hydrodensitometry (HD) in women (n = 225) and men (n = 110) across a 21- to 81-yr age range (experiment 2). For experiment 1, 10 subjects underwent DEXA procedures in a control condition and with packets of lard positioned over either the thighs or the truncal region. DEXA accurately quantified the additional mass as approximately 96% fat, regardless of position. For experiment 2, DEXA yielded higher (P fatness than did HD (32.1 +/- 12.0 vs. 31.2 +/- 10.1%). The mean difference between the two methods was similar in young, middle-aged, and older subjects, but was different in men (HD-DEXA, 1.6 +/- 3.4% of body wt) than in women (-2.1 +/- 3.8% of body wt). Correcting the density of fat-free mass for variance in the bone mineral fraction of fat-free mass reduced the difference between the methods in men from 1.6 +/- 3.4 to -0.7 +/- 2.9% but widened it in women from -2.1 +/- 3.8 to -3.5 +/- 3.4%. A second correction procedure that adjusted for variance in water, protein, and mineral fractions of fat-free mass eliminated the differences in estimates of fat content by DEXA and HD in both men (21.1 +/- 9.3 vs. 20.6 +/- 8.4%, respectively) and women (37.5 +/- 9.3 vs. 36.8 +/- 8.0%, respectively). These results provide encouraging, but not definitive, evidence that the assessment of body composition by DEXA is accurate under the specified conditions.

  7. Rapid and accurate determination of the lignin content of lignocellulosic biomass by solid-state NMR.

    Science.gov (United States)

    Fu, Li; McCallum, Scott A; Miao, Jianjun; Hart, Courtney; Tudryn, Gregory J; Zhang, Fuming; Linhardt, Robert J

    2015-02-01

    Biofuels and biomaterials, produced from lignocellulosic feedstock, require facile access to cellulose and hemicellulose to be competitive with petroleum processing and sugar-based fermentation. Physical-chemical barriers resulting from lignin complicates the hydrolysis biomass into fermentable sugars. Thus, the amount of lignin within a substrate is critical in determining biomass processing. The application of 13 C cross-polarization, magic-angle spinning, and solid-state nuclear magnetic resonance for the direct quantification of lignin content in biomass is examined. Using a standard curve constructed from pristine lignin and cellulose, the lignin content of a biomass sample is accurately determined through direct measurement without chemical or enzymatic pre-treatment.

  8. Rapid and accurate prediction and scoring of water molecules in protein binding sites.

    Directory of Open Access Journals (Sweden)

    Gregory A Ross

    Full Text Available Water plays a critical role in ligand-protein interactions. However, it is still challenging to predict accurately not only where water molecules prefer to bind, but also which of those water molecules might be displaceable. The latter is often seen as a route to optimizing affinity of potential drug candidates. Using a protocol we call WaterDock, we show that the freely available AutoDock Vina tool can be used to predict accurately the binding sites of water molecules. WaterDock was validated using data from X-ray crystallography, neutron diffraction and molecular dynamics simulations and correctly predicted 97% of the water molecules in the test set. In addition, we combined data-mining, heuristic and machine learning techniques to develop probabilistic water molecule classifiers. When applied to WaterDock predictions in the Astex Diverse Set of protein ligand complexes, we could identify whether a water molecule was conserved or displaced to an accuracy of 75%. A second model predicted whether water molecules were displaced by polar groups or by non-polar groups to an accuracy of 80%. These results should prove useful for anyone wishing to undertake rational design of new compounds where the displacement of water molecules is being considered as a route to improved affinity.

  9. Rapid yet accurate measurement of mass diffusion coefficients by phase shifting interferometer

    CERN Document Server

    Guo Zhi Xiong; Komiya, A

    1999-01-01

    The technique of using a phase-shifting interferometer is applied to the study of diffusion in transparent liquid mixtures. A quick method is proposed for determining the diffusion coefficient from the measurements of the location of fringes on a grey level picture. The measurement time is very short (within 100 s) and a very small transient diffusion field can be observed and recorded accurately with a rate of 30 frames per second. The measurement can be completed using less than 0.12 cc of solutions. The influence of gravity on the measurement of the diffusion coefficient is eliminated in the present method. Results on NaCl-water diffusion systems are presented and compared with the reference data. (author)

  10. Accurate and rapid optical characterization of an anisotropic guided structure based on a neural method.

    Science.gov (United States)

    Robert, Stéphane; Battie, Yann; Jamon, Damien; Royer, Francois

    2007-04-10

    Optimal performances of integrated optical devices are obtained by the use of an accurate and reliable characterization method. The parameters of interest, i.e., optical indices and thickness of the waveguide structure, are calculated from effective indices by means of an inversion procedure. We demonstrate how an artificial neural network can achieve such a process. The artificial neural network used is a multilayer perceptron. The first result concerns a simulated anisotropic waveguide. The accuracy in the determination of optical indices and waveguide thickness is 5 x 10(-5) and 4 nm, respectively. Then an experimental application on a silica-titania thin film is performed. In addition, effective indices are measured by m-lines spectroscopy. Finally, a comparison with a classical optimization algorithm demonstrates the robustness of the neural method.

  11. Rapid yet accurate first principle based predictions of alkali halide crystal phases using alchemical perturbation

    CERN Document Server

    Solovyeva, Alisa

    2016-01-01

    We assess the predictive power of alchemical perturbations for estimating fundamental properties in ionic crystals. Using density functional theory we have calculated formation energies, lattice constants, and bulk moduli for all sixteen iso-valence-electronic combinations of pure pristine alkali halides involving elements $A \\in \\{$Na, K, Rb, Cs$\\}$ and $X \\in \\{$F, Cl, Br, I$\\}$. For rock salt, zincblende and cesium chloride symmetry, alchemical Hellmann-Feynman derivatives, evaluated along lattice scans of sixteen reference crystals, have been obtained for all respective 16$\\times$15 combinations of reference and predicted target crystals. Mean absolute errors (MAE) are on par with density functional theory level of accuracy for energies and bulk modulus. Predicted lattice constants are less accurate. NaCl is the best reference salt for alchemical estimates of relative energies (MAE $<$ 40 meV/atom) while alkali fluorides are the worst. By contrast, lattice constants are predicted best using NaF as a re...

  12. A rapid, highly accurate method for quantifying CALR mutant allele burden in persons with myeloproliferative neoplasms.

    Science.gov (United States)

    Yao, Qiu-Mei; Zhou, Jiao; Gale, Robert Peter; Li, Jin-Lan; Li, Ling-Di; Li, Ning; Chen, Shan-Shan; Ruan, Guo-Rui

    2015-10-01

    Calreticulin (CALR) mutations were recently identified in a substantial proportion of persons with essential thrombocythemia (ET) and with primary myelofibrosis (PMF) without JAK2(V617F). Consequently rapid, sensitive, and specific methods to detect and quantify these mutations are needed. We studied samples from 1088 persons with myeloproliferative neoplasms (MPNs) including 421 JAK2(V617F) negative subjects with ET, PMF, polycythemia vera (PV), chronic myeloid leukemia (CML) and hyper-eosinophilic syndrome (HES). Detection of CALR exon 9 mutations was done by PCR amplification followed by fragment length analysis and direct sequencing. Dilution assays were used to determine CALR mutant allele burden. We detected CALR mutations in blood and bone marrow samples from 152 subjects with ET and with PMF but not in samples from normal or persons with PV, CML, or HES. CALR mutant peaks were distinct from wild-type peaks and dilution experiments indicated a sensitivity level of 0.5-5% for a CALR mutant allele in a wild-type background. Diverse types of mutations were detected including deletions, insertions, and complex indels. All mutations were confirmed by direct sequencing. We also used dilution experiments to quantify mutant allele burden. We were able to reproducibly detect mutant allele levels as low 5% (0.5-5%) in a wild-type background. PCR amplification followed by fragment length analysis is a rapid, sensitive, and specific method for screening persons with MPNs for CALR mutations, especially those with ET and PMF and for estimating mutant allele burden.

  13. Bacterial Cytological Profiling (BCP as a Rapid and Accurate Antimicrobial Susceptibility Testing Method for Staphylococcus aureus

    Directory of Open Access Journals (Sweden)

    D.T. Quach

    2016-02-01

    Full Text Available Successful treatment of bacterial infections requires the timely administration of appropriate antimicrobial therapy. The failure to initiate the correct therapy in a timely fashion results in poor clinical outcomes, longer hospital stays, and higher medical costs. Current approaches to antibiotic susceptibility testing of cultured pathogens have key limitations ranging from long run times to dependence on prior knowledge of genetic mechanisms of resistance. We have developed a rapid antimicrobial susceptibility assay for Staphylococcus aureus based on bacterial cytological profiling (BCP, which uses quantitative fluorescence microscopy to measure antibiotic induced changes in cellular architecture. BCP discriminated between methicillin-susceptible (MSSA and -resistant (MRSA clinical isolates of S. aureus (n = 71 within 1–2 h with 100% accuracy. Similarly, BCP correctly distinguished daptomycin susceptible (DS from daptomycin non-susceptible (DNS S. aureus strains (n = 20 within 30 min. Among MRSA isolates, BCP further identified two classes of strains that differ in their susceptibility to specific combinations of beta-lactam antibiotics. BCP provides a rapid and flexible alternative to gene-based susceptibility testing methods for S. aureus, and should be readily adaptable to different antibiotics and bacterial species as new mechanisms of resistance or multidrug-resistant pathogens evolve and appear in mainstream clinical practice.

  14. Use of flow cytometry for rapid and accurate enumeration of live pathogenic Leptospira strains.

    Science.gov (United States)

    Fontana, Célia; Crussard, Steve; Simon-Dufay, Nathalie; Pialot, Daniel; Bomchil, Natalia; Reyes, Jean

    2017-01-01

    Enumeration of Leptospira, the causative agent of leptospirosis, is arduous mainly because of its slow growth rate. Rapid and reliable tools for numbering leptospires are still lacking. The current standard for Leptospira cultures is the count on Petroff-Hausser chamber under dark-field microscopy, but this method remains time-consuming, requires well-trained operators and lacks reproducibility. Here we present the development of a flow-cytometry technique for counting leptospires. We showed that upon addition of fluorescent dyes, necessary to discriminate the bacterial population from debris, several live Leptospira strains could be enumerated at different physiologic states. Flow cytometry titers were highly correlated to counts with Petroff-Hausser chambers (R(2)>0.99). Advantages of flow cytometry lie in its rapidity, its reproducibility significantly higher than Petroff-Hausser method and its wide linearity range, from 10(4) to 10(8)leptospires/ml. Therefore, flow cytometry is a fast, reproducible and sensitive tool representing a promising technology to replace current enumeration techniques of Leptospira in culture. We were also able to enumerate Leptospira in artificially infected urine and blood with a sensitivity limit of 10(5)leptospires/ml and 10(6)leptospires/ml, respectively, demonstrating the feasibility to use flow cytometry as first-line tool for diagnosis or bacterial dissemination studies. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Molecular Detection of Foodborne Pathogens: A Rapid and Accurate Answer to Food Safety.

    Science.gov (United States)

    Mangal, Manisha; Bansal, Sangita; Sharma, Satish K; Gupta, Ram K

    2016-07-03

    Food safety is a global health concern. For the prevention and recognition of problems related to health and safety, detection of foodborne pathogen is of utmost importance at all levels of food production chain. For several decades, a lot of research has been targeted at the development of rapid methodology as reducing the time needed to complete pathogen detection tests has been the primary goal of food microbiologists. With the result, food microbiology laboratories now have a wide array of detection methods and automated technologies such as enzyme immunoassay, polymerase chain reaction, and microarrays, which can cut test times considerably. Nucleic acid amplification strategies and advances in amplicon detection methodologies have been the key factors in the progress of molecular microbiology. A comprehensive literature survey has been carried out to give an overview in the field of foodborne pathogen detection. In this paper, we describe the conventional methods, as well as recent developments in food pathogen detection, identification, and quantification, with a major emphasis on molecular detection methods.

  16. Rapid and Accurate MRI Segmentation of Peritumoral Brain Edema in Meningiomas.

    Science.gov (United States)

    Latini, F; Larsson, E-M; Ryttlefors, M

    2017-06-01

    The extent of peritumoral brain edema (PTBE) in meningiomas commonly affects the clinical outcome. Despite its importance, edema volume is usually highly inaccurately approximated to a spheroid shape. We tested the accuracy and the reproducibility of semiautomatic lesion management software for the analysis of PTBE in a homogeneous case series of surgically confirmed intracranial meningiomas. PTBE volume was calculated on magnetic resonance images in 50 patients with intracranial meningiomas using commercial lesion management software (Vue PACS Livewire, Carestream, Rochester, NY, USA). Inter and intraobserver agreement evaluation and a comparison between manual volume calculation, the semiautomatic software and spheroid approximation were performed in 22 randomly selected patients. The calculation of edema volume was possible in all cases irrespective of the extent of the signal changes. The median time for each calculation was 3 min. Interobserver and intraobserver agreement confirmed the reproducibility of the method. Comparison with standard (fully manual) calculation confirmed the accuracy of this software. Our study showed a high level of reproducibility of this semiautomatic computational method for peritumoral brain edema. It is rapid and easy to use after relatively short training and is suitable for implementation in clinical practice.

  17. OrthoReD: a rapid and accurate orthology prediction tool with low computational requirement.

    Science.gov (United States)

    Battenberg, Kai; Lee, Ernest K; Chiu, Joanna C; Berry, Alison M; Potter, Daniel

    2017-06-21

    Identifying orthologous genes is an initial step required for phylogenetics, and it is also a common strategy employed in functional genetics to find candidates for functionally equivalent genes across multiple species. At the same time, in silico orthology prediction tools often require large computational resources only available on computing clusters. Here we present OrthoReD, an open-source orthology prediction tool with accuracy comparable to published tools that requires only a desktop computer. The low computational resource requirement of OrthoReD is achieved by repeating orthology searches on one gene of interest at a time, thereby generating a reduced dataset to limit the scope of orthology search for each gene of interest. The output of OrthoReD was highly similar to the outputs of two other published orthology prediction tools, OrthologID and/or OrthoDB, for the three dataset tested, which represented three phyla with different ranges of species diversity and different number of genomes included. Median CPU time for ortholog prediction per gene by OrthoReD executed on a desktop computer was <15 min even for the largest dataset tested, which included all coding sequences of 100 bacterial species. With high-throughput sequencing, unprecedented numbers of genes from non-model organisms are available with increasing need for clear information about their orthologies and/or functional equivalents in model organisms. OrthoReD is not only fast and accurate as an orthology prediction tool, but also gives researchers flexibility in the number of genes analyzed at a time, without requiring a high-performance computing cluster.

  18. Rapid and accurate tumor-target bio-imaging through specific in vivo biosynthesis of a fluorescent europium complex.

    Science.gov (United States)

    Ye, Jing; Wang, Jianling; Li, Qiwei; Dong, Xiawei; Ge, Wei; Chen, Yun; Jiang, Xuerui; Liu, Hongde; Jiang, Hui; Wang, Xuemei

    2016-04-01

    A new and facile method for rapidly and accurately achieving tumor targeting fluorescent images has been explored using a specifically biosynthesized europium (Eu) complex in vivo and in vitro. It demonstrated that a fluorescent Eu complex could be bio-synthesized through a spontaneous molecular process in cancerous cells and tumors, but not prepared in normal cells and tissues. In addition, the proteomics analyses show that some biological pathways of metabolism, especially for NADPH production and glutamine metabolism, are remarkably affected during the relevant biosynthesis process, where molecular precursors of europium ions are reduced to fluorescent europium complexes inside cancerous cells or tumor tissues. These results proved that the specific self-biosynthesis of a fluorescent Eu complex by cancer cells or tumor tissues can provide a new strategy for accurate diagnosis and treatment strategies in the early stages of cancers and thus is beneficial for realizing precise surgical intervention based on the relevant cheap and readily available agents.

  19. Rapid and accurate identification of Xanthomonas citri subspecies citri by fluorescence in situ hybridization.

    Science.gov (United States)

    Waite, D W; Griffin, R; Taylor, R; George, S

    2016-11-01

    Citrus canker is an economically important disease caused by the bacterial pathogen Xanthomonas citri subsp. citri (Xcc). This organism targets a wide range of citrus plants, including sweet orange, grapefruit, lemon and lime. As Xcc is spread by environmental factors such as wind and rain, it is difficult to control its movement once the disease has established. In order to facilitate monitoring of citrus canker we sought to design a novel diagnostic protocol based on fluorescence in situ hybridization (FISH) for identification of bacterial cells directly from canker pustules without cultivation or DNA extraction. This method was validated for specificity against a range of Xanthomonas species and strains. We show that our assay is extremely rapid (typically requiring between 2 and 3 h), and possesses a similar specificity to existing PCR diagnostic tools. The sensitivity of the assay is comparable to that of an existing PCR-based technique and sufficient for identifying Xcc in symptomatic plant material. The method is easily transferable to diagnosticians without prior experience using FISH. Xanthomonas citri subsp. citri (Xcc) is an aggressive and hardy pathogen of citrus plants worldwide. Outbreaks are difficult and costly to contain and the establishment of citrus canker results in restricted trade. In order to extend the existing toolkit for identification of Xcc we developed a novel diagnostic approach based on fluorescence in situ hybridization. Our approach is of comparable specificity and sensitivity to existing methods but can be performed directly on infected tissue making it significantly faster than existing PCRs, and requiring fewer laboratory resources. © 2016 The Society for Applied Microbiology.

  20. Fourier Transform Mass Spectrometry and Nuclear Magnetic Resonance Analysis for the Rapid and Accurate Characterization of Hexacosanoylceramide.

    Science.gov (United States)

    Ross, Charles W; Simonsick, William J; Bogusky, Michael J; Celikay, Recep W; Guare, James P; Newton, Randall C

    2016-06-28

    Ceramides are a central unit of all sphingolipids which have been identified as sites of biological recognition on cellular membranes mediating cell growth and differentiation. Several glycosphingolipids have been isolated, displaying immunomodulatory and anti-tumor activities. These molecules have generated considerable interest as potential vaccine adjuvants in humans. Accurate analyses of these and related sphingosine analogues are important for the characterization of structure, biological function, and metabolism. We report the complementary use of direct laser desorption ionization (DLDI), sheath flow electrospray ionization (ESI) Fourier transform ion cyclotron resonance mass spectrometry (FTICR MS) and high-field nuclear magnetic resonance (NMR) analysis for the rapid, accurate identification of hexacosanoylceramide and starting materials. DLDI does not require stringent sample preparation and yields representative ions. Sheath-flow ESI yields ions of the product and byproducts and was significantly better than monospray ESI due to improved compound solubility. Negative ion sheath flow ESI provided data of starting materials and products all in one acquisition as hexacosanoic acid does not ionize efficiently when ceramides are present. NMR provided characterization of these lipid molecules complementing the results obtained from MS analyses. NMR data was able to differentiate straight chain versus branched chain alkyl groups not easily obtained from mass spectrometry.

  1. Rapid and accurate analyses of silicon and phosphorus in plants using a portable X-ray fluorescence spectrometer.

    Science.gov (United States)

    Reidinger, Stefan; Ramsey, Michael H; Hartley, Susan E

    2012-08-01

    The elemental analysis of plant material is a frequently employed tool across biological disciplines, yet accurate, convenient and economical methods for the determination of some important elements are currently lacking. For instance, digestion-based techniques are often hazardous and time-consuming and, particularly in the case of silicon (Si), can suffer from low accuracy due to incomplete solubilization and potential volatilization, whilst other methods may require large, expensive and specialised equipment. Here, we present a rapid, safe and accurate procedure for the simultaneous, nonconsumptive analysis of Si and phosphorus (P) in as little as 0.1 g dried and ground plant material using a portable X-ray fluorescence spectrometer (P-XRF). We used certified reference materials from different plant species to test the analytical performance of P-XRF and show that the analysis suffers from very little bias and that the repeatability precision of the measurements is as good as or better than that of other methods. Using this technique we were able to process and analyse 200 ground samples a day, so P-XRF could provide a particularly valuable tool for plant biologists requiring the simultaneous nonconsumptive analysis of multiple elements, including those known to be difficult to measure such as Si, in large numbers of samples. © 2012 The Authors. New Phytologist © 2012 New Phytologist Trust.

  2. Fourier Transform Mass Spectrometry and Nuclear Magnetic Resonance Analysis for the Rapid and Accurate Characterization of Hexacosanoylceramide

    Directory of Open Access Journals (Sweden)

    Charles W. Ross

    2016-06-01

    Full Text Available Ceramides are a central unit of all sphingolipids which have been identified as sites of biological recognition on cellular membranes mediating cell growth and differentiation. Several glycosphingolipids have been isolated, displaying immunomodulatory and anti-tumor activities. These molecules have generated considerable interest as potential vaccine adjuvants in humans. Accurate analyses of these and related sphingosine analogues are important for the characterization of structure, biological function, and metabolism. We report the complementary use of direct laser desorption ionization (DLDI, sheath flow electrospray ionization (ESI Fourier transform ion cyclotron resonance mass spectrometry (FTICR MS and high-field nuclear magnetic resonance (NMR analysis for the rapid, accurate identification of hexacosanoylceramide and starting materials. DLDI does not require stringent sample preparation and yields representative ions. Sheath-flow ESI yields ions of the product and byproducts and was significantly better than monospray ESI due to improved compound solubility. Negative ion sheath flow ESI provided data of starting materials and products all in one acquisition as hexacosanoic acid does not ionize efficiently when ceramides are present. NMR provided characterization of these lipid molecules complementing the results obtained from MS analyses. NMR data was able to differentiate straight chain versus branched chain alkyl groups not easily obtained from mass spectrometry.

  3. Development of improved enzyme-based and lateral flow immunoassays for rapid and accurate serodiagnosis of canine brucellosis.

    Science.gov (United States)

    Cortina, María E; Novak, Analía; Melli, Luciano J; Elena, Sebastián; Corbera, Natalia; Romero, Juan E; Nicola, Ana M; Ugalde, Juan E; Comerci, Diego J; Ciocchini, Andrés E

    2017-09-01

    Brucellosis is a widespread zoonotic disease caused by Brucella spp. Brucella canis is the etiological agent of canine brucellosis, a disease that can lead to sterility in bitches and dogs causing important economic losses in breeding kennels. Early and accurate diagnosis of canine brucellosis is central to control the disease and lower the risk of transmission to humans. Here, we develop and validate enzyme and lateral flow immunoassays for improved serodiagnosis of canine brucellosis using as antigen the B. canis rough lipopolysaccharide (rLPS). The method used to obtain the rLPS allowed us to produce more homogeneous batches of the antigen that facilitated the standardization of the assays. To validate the assays, 284 serum samples obtained from naturally infected dogs and healthy animals were analyzed. For the B. canis-iELISA and B. canis-LFIA the diagnostic sensitivity was of 98.6%, and the specificity 99.5% and 100%, respectively. We propose the implementation of the B. canis-LFIA as a screening test in combination with the highly accurate laboratory g-iELISA. The B. canis-LFIA is a rapid, accurate and easy to use test, characteristics that make it ideal for the serological surveillance of canine brucellosis in the field or veterinary laboratories. Finally, a blind study including 1040 serum samples obtained from urban dogs showed a prevalence higher than 5% highlighting the need of new diagnostic tools for a more effective control of the disease in dogs and therefore to reduce the risk of transmission of this zoonotic pathogen to humans. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Evaluation of a pan-serotype point-of-care rapid diagnostic assay for accurate detection of acute dengue infection.

    Science.gov (United States)

    Vivek, Rosario; Ahamed, Syed Fazil; Kotabagi, Shalini; Chandele, Anmol; Khanna, Ira; Khanna, Navin; Nayak, Kaustuv; Dias, Mary; Kaja, Murali-Krishna; Shet, Anita

    2017-03-01

    The catastrophic rise in dengue infections in India and globally has created a need for an accurate, validated low-cost rapid diagnostic test (RDT) for dengue. We prospectively evaluated the diagnostic performance of NS1/IgM RDT (dengue day 1) using 211 samples from a pediatric dengue cohort representing all 4 serotypes in southern India. The dengue-positive panel consisted of 179 dengue real-time polymerase chain reaction (RT-PCR) positive samples from symptomatic children. The dengue-negative panel consisted of 32 samples from dengue-negative febrile children and asymptomatic individuals that were negative for dengue RT-PCR/NS1 enzyme-linked immunosorbent assay/IgM/IgG. NS1/IgM RDT sensitivity was 89.4% and specificity was 93.8%. The NS1/IgM RDT showed high sensitivity throughout the acute phase of illness, in primary and secondary infections, in different severity groups, and detected all 4 dengue serotypes, including coinfections. This NS1/IgM RDT is a useful point-of-care assay for rapid and reliable diagnosis of acute dengue and an excellent surveillance tool in our battle against dengue. Copyright © 2016. Published by Elsevier Inc.

  5. Evaluation of a novel immunochromatographic device for rapid and accurate clinical detection of Porphyromonas gingivalis in subgingival plaque.

    Science.gov (United States)

    Imamura, K; Takayama, S; Saito, A; Inoue, E; Nakayama, Y; Ogata, Y; Shirakawa, S; Nagano, T; Gomi, K; Morozumi, T; Akiishi, K; Watanabe, K; Yoshie, H

    2015-10-01

    An important goal for the improved diagnosis and management of infectious and inflammatory diseases, such as periodontitis, is the development of rapid and accurate technologies for the decentralized detection of bacterial pathogens. The aim of this prospective multicenter study was to evaluate the clinical use of a novel immunochromatographic device with monoclonal antibodies for the rapid point-of-care detection and semi-quantification of Porphyromonas gingivalis in subgingival plaque. Sixty-three patients with chronic periodontitis and 28 periodontally healthy volunteers were subjected to clinical and microbiological examinations. Subgingival plaque samples were analyzed for the presence of P. gingivalis using a novel immunochromatography based device DK13-PG-001, designed to detect the 40k-outer membrane protein of P. gingivalis, and compared with a PCR-Invader method. In the periodontitis group, a significant strong positive correlation in detection results was found between the test device score and the PCR-Invader method (Spearman rank correlation, r=0.737, pgingivalis, whereas 76% (n=48) of periodontitis subjects were tested positive. There was a significant positive correlation between device scores for P. gingivalis and periodontal parameters including probing pocket depth and clinical attachment level (r=0.317 and 0.281, respectively, pgingivalis in subgingival plaque. UMIN Clinical Trials Registry (UMIN-CTR) UMIN000011943. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Accurate and rapid identification of the Burkholderia pseudomallei near-neighbour, Burkholderia ubonensis, using real-time PCR.

    Science.gov (United States)

    Price, Erin P; Sarovich, Derek S; Webb, Jessica R; Ginther, Jennifer L; Mayo, Mark; Cook, James M; Seymour, Meagan L; Kaestli, Mirjam; Theobald, Vanessa; Hall, Carina M; Busch, Joseph D; Foster, Jeffrey T; Keim, Paul; Wagner, David M; Tuanyok, Apichai; Pearson, Talima; Currie, Bart J

    2013-01-01

    Burkholderia ubonensis is an environmental bacterium belonging to the Burkholderia cepacia complex (Bcc), a group of genetically related organisms that are associated with opportunistic but generally nonfatal infections in healthy individuals. In contrast, the near-neighbour species Burkholderia pseudomallei causes melioidosis, a disease that can be fatal in up to 95% of cases if left untreated. B. ubonensis is frequently misidentified as B. pseudomallei from soil samples using selective culturing on Ashdown's medium, reflecting both the shared environmental niche and morphological similarities of these species. Additionally, B. ubonensis shows potential as an important biocontrol agent in B. pseudomallei-endemic regions as certain strains possess antagonistic properties towards B. pseudomallei. Current methods for characterising B. ubonensis are laborious, time-consuming and costly, and as such this bacterium remains poorly studied. The aim of our study was to develop a rapid and inexpensive real-time PCR-based assay specific for B. ubonensis. We demonstrate that a novel B. ubonensis-specific assay, Bu550, accurately differentiates B. ubonensis from B. pseudomallei and other species that grow on selective Ashdown's agar. We anticipate that Bu550 will catalyse research on B. ubonensis by enabling rapid identification of this organism from Ashdown's-positive colonies that are not B. pseudomallei.

  7. Accurate and rapid identification of the Burkholderia pseudomallei near-neighbour, Burkholderia ubonensis, using real-time PCR.

    Directory of Open Access Journals (Sweden)

    Erin P Price

    Full Text Available Burkholderia ubonensis is an environmental bacterium belonging to the Burkholderia cepacia complex (Bcc, a group of genetically related organisms that are associated with opportunistic but generally nonfatal infections in healthy individuals. In contrast, the near-neighbour species Burkholderia pseudomallei causes melioidosis, a disease that can be fatal in up to 95% of cases if left untreated. B. ubonensis is frequently misidentified as B. pseudomallei from soil samples using selective culturing on Ashdown's medium, reflecting both the shared environmental niche and morphological similarities of these species. Additionally, B. ubonensis shows potential as an important biocontrol agent in B. pseudomallei-endemic regions as certain strains possess antagonistic properties towards B. pseudomallei. Current methods for characterising B. ubonensis are laborious, time-consuming and costly, and as such this bacterium remains poorly studied. The aim of our study was to develop a rapid and inexpensive real-time PCR-based assay specific for B. ubonensis. We demonstrate that a novel B. ubonensis-specific assay, Bu550, accurately differentiates B. ubonensis from B. pseudomallei and other species that grow on selective Ashdown's agar. We anticipate that Bu550 will catalyse research on B. ubonensis by enabling rapid identification of this organism from Ashdown's-positive colonies that are not B. pseudomallei.

  8. Use of Fourier transform infrared spectroscopy (FTIR spectroscopy for rapid and accurate identification of Yeasts isolated from human and animals

    Directory of Open Access Journals (Sweden)

    M. Taha

    2013-06-01

    Full Text Available Rapid and accurate identification of yeast is increasingly important to stipulate the appropriate therapy thus reducing morbidity and mortality related to yeast infections. Vibrational spectroscopic techniques (infrared (IR and Raman could provide potential alternatives to conventional typing methods, because they constitute a rapid, inexpensive and highly specific spectroscopic fingerprint through-which microorganism can be identified. The present study evaluate (FTIR spectroscopy as a sensitive and effective assay for the identification of the most frequent yeast species isolated from human and animals. One hundred and twenty-eight yeasts isolated from infected human mouths/vaginas, chronic diseased cows, crop mycosis in chicken and soil contaminated with pigeon droppings were phenotypically identified. Using universal primers, ITS1/ITS4, we have amplified ITS1-5.8S-ITS2 rDNA regions for 39 yeast isolates as representative samples. The PCR products were digested with restriction enzyme MspI and examined by PCR-RFLP, which was an efficient technique for identification of Candida spp., Cryptococcus neoformans and Trichosporon asahii. Further, identification of the same 39 isolates were done by FTIR spectroscopy and considered as reference for other strains by comparison of their FTIR spectra. The current study has sharply demonstrated the significant spectral differences between the various examined species of Candida, Cryptococcus, Trichosporon, Rhodotorula and Geotrichum isolated from different sources. Decisively, our research has confirmed that FTIR spectroscopy is a promising diagnostic tool, because of its sensitivity, rapidity, high differentiation capacity and simplicity compared to conventional/molecular techniques.

  9. Rapid screening of wheat bran contaminated by deoxynivalenol mycotoxin using Raman spectroscopy: a preliminary experiment

    Science.gov (United States)

    Mignani, A. G.; Ciaccheri, L.; Mencaglia, A. A.; De Girolamo, A.; Lippolis, V.; Pascale, M.

    2016-05-01

    Deoxynivalenol (DON) is a mycotoxin frequently occurring in cereals and derived products, and regulated in many countries. Raman spectroscopy performed using optical fibers, with excitation at 1064 nm and a dispersive detection scheme, was utilized to analyze wheat bran samples naturally contaminated with DON. A multivariate processing of the spectroscopic data allowed to distinguish two classes of contamination, with DON below and above 400 μg/kg, respectively. Only one highly contaminated sample was misclassified. This preliminary result demonstrates the potential of Raman spectroscopy as a useful analytical tool for the non-destructive and rapid analysis of mycotoxins in food.

  10. A tool for rapid assessment of product usability and universal design: development and preliminary psychometric testing.

    Science.gov (United States)

    Lenker, James A; Nasarwanji, Mahiyar; Paquet, Victor; Feathers, David

    2011-01-01

    While there are many available tools and methods to evaluate product usability, few have been tested on user groups with disabilities and even fewer systematically consider universal design principles. This paper describes the development and preliminary psychometric testing of the Rapid Assessment of Product Usability & Universal Design (RAPUUD), a 12-item user-report tool based on the seven principles of universal design. A preliminary set of items was created to elicit ratings of diverse product characteristics (e.g., physical effort, cognitive effort, assistance required, safety). Data were gathered from 61 participants who rated the usability of products they use in their own environments. Each item elicited a full range of responses, with no apparent floor or ceiling effects. Collectively, the 12 items achieved a high internal consistency (Cronbach's α=0.80). The data indicate that the tool was sensitive to differences in functional abilities, as well as differences in product characteristics. The instrument was usable for a range of consumer products, though not all items were appropriate for each and every product. The results suggest that the instrument could become a pragmatic tool for designers to identify usability problems experienced by a diversity of user populations. © 2011 - IOS Press and the authors. All rights reserved

  11. Are rapid diagnostic tests more accurate in diagnosis of plasmodium falciparum malaria compared to microscopy at rural health centres?

    Directory of Open Access Journals (Sweden)

    Magnussen Pascal

    2010-12-01

    Full Text Available Abstract Background Prompt, accurate diagnosis and treatment with artemisinin combination therapy remains vital to current malaria control. Blood film microscopy the current standard test for diagnosis of malaria has several limitations that necessitate field evaluation of alternative diagnostic methods especially in low income countries of sub-Saharan Africa where malaria is endemic. Methods The accuracy of axillary temperature, health centre (HC microscopy, expert microscopy and a HRP2-based rapid diagnostic test (Paracheck was compared in predicting malaria infection using polymerase chain reaction (PCR as the gold standard. Three hundred patients with a clinical suspicion of malaria based on fever and or history of fever from a low and high transmission setting in Uganda were consecutively enrolled and provided blood samples for all tests. Accuracy of each test was calculated overall with 95% confidence interval and then adjusted for age-groups and level of transmission intensity using a stratified analysis. The endpoints were: sensitivity, specificity, positive predictive value (PPV and negative predictive value (NPV. This study is registered with Clinicaltrials.gov, NCT00565071. Results Of the 300 patients, 88(29.3% had fever, 56(18.7% were positive by HC microscopy, 47(15.7% by expert microscopy, 110(36.7% by Paracheck and 89(29.7% by PCR. The overall sensitivity >90% was only shown by Paracheck 91.0% [95%CI: 83.1-96.0]. The sensitivity of expert microscopy was 46%, similar to HC microscopy. The superior sensitivity of Paracheck compared to microscopy was maintained when data was stratified for transmission intensity and age. The overall specificity rates were: Paracheck 86.3% [95%CI: 80.9-90.6], HC microscopy 93.4% [95%CI: 89.1-96.3] and expert microscopy 97.2% [95%CI: 93.9-98.9]. The NPV >90% was shown by Paracheck 95.8% [95%CI: 91.9-98.2]. The overall PPV was Conclusion The HRP2-based RDT has shown superior sensitivity compared to

  12. Rapid Bayesian point source inversion using pattern recognition --- bridging the gap between regional scaling relations and accurate physical modelling

    Science.gov (United States)

    Valentine, A. P.; Kaeufl, P.; De Wit, R. W. L.; Trampert, J.

    2014-12-01

    Obtaining knowledge about source parameters in (near) real-time during or shortly after an earthquake is essential for mitigating damage and directing resources in the aftermath of the event. Therefore, a variety of real-time source-inversion algorithms have been developed over recent decades. This has been driven by the ever-growing availability of dense seismograph networks in many seismogenic areas of the world and the significant advances in real-time telemetry. By definition, these algorithms rely on short time-windows of sparse, local and regional observations, resulting in source estimates that are highly sensitive to observational errors, noise and missing data. In order to obtain estimates more rapidly, many algorithms are either entirely based on empirical scaling relations or make simplifying assumptions about the Earth's structure, which can in turn lead to biased results. It is therefore essential that realistic uncertainty bounds are estimated along with the parameters. A natural means of propagating probabilistic information on source parameters through the entire processing chain from first observations to potential end users and decision makers is provided by the Bayesian formalism.We present a novel method based on pattern recognition allowing us to incorporate highly accurate physical modelling into an uncertainty-aware real-time inversion algorithm. The algorithm is based on a pre-computed Green's functions database, containing a large set of source-receiver paths in a highly heterogeneous crustal model. Unlike similar methods, which often employ a grid search, we use a supervised learning algorithm to relate synthetic waveforms to point source parameters. This training procedure has to be performed only once and leads to a representation of the posterior probability density function p(m|d) --- the distribution of source parameters m given observations d --- which can be evaluated quickly for new data.Owing to the flexibility of the pattern

  13. A rapid, accurate and robust particle-based assay for the simultaneous screening of plasma samples for the presence of five different anti-cytokine autoantibodies

    DEFF Research Database (Denmark)

    Guldager, Daniel Kring Rasmussen; von Stemann, Jakob Hjorth; Larsen, Rune

    2015-01-01

    PURPOSE: To establish and validate a rapid, cost-effective and accurate screening assay for the simultaneous testing of human naturally occurring anti-cytokine autoantibodies (c-aAb) targeting interleukin-1α (IL-1α), interleukin-6 (IL-6), interleukin-10 (IL-10), granulocyte-macrophage colony...

  14. Rapid and Accurate Identification of Adulterants via an Electronic Nose and DNA Identification Platform: Identification of Fake Velvet Antlers as an Example

    OpenAIRE

    Guojie Xu; Chunsheng Liu; Caili Liao; Xiaolei Ren; Xinyue Zhang; Xiaorui Fu; Xueyong Wang

    2016-01-01

    Background. Adulterants in Chinese medicines had always affected the efficacy of Chinese medicines and resulted in safety problems in drug use. We aimed to take the identification of fake velvet antlers as an example for establishment of a rapid and accurate identification platform for modern pharmaceutical companies and markets of Chinese medicine. Methods. In this study, we developed a novel electronic nose and DNA identification platform for identifying fake velvet antlers. Electronic nose...

  15. Preliminary Inter-Comparison between AHI, VIIRS and MODIS Clear-Sky Ocean Radiances for Accurate SST Retrievals

    Directory of Open Access Journals (Sweden)

    Xingming Liang

    2016-03-01

    Full Text Available Clear-sky brightness temperatures (BT in five bands of the Advanced Himawari Imager (AHI; flown onboard Himawari-8 satellite centered at 3.9, 8.6, 10.4, 11.2, and 12.3 µm (denoted by IR37, IR86, IR10, IR11, and IR12, respectively are used in the NOAA Advanced Clear-Sky Processor for Oceans (ACSPO sea surface temperature (SST retrieval system. Here, AHI BTs are preliminarily evaluated for stability and consistency with the corresponding VIIRS and MODIS BTs, using the sensor observation minus model simulation (O-M biases and corresponding double differences. The objective is to ensure accurate and consistent SST products from the polar and geo sensors, and to prepare for the launch of the GOES-R satellite in 2016. All five AHI SST bands are found to be largely in-family with their polar counterparts, but biased low relative to the VIIRS and MODIS (which, in turn, were found to be stable and consistent, except for Terra IR86, which is biased high by 1.5 K. The negative biases are larger in IR37 and IR12 (up to ~−0.5 K, followed by the three remaining longwave IR bands IR86, IR10, and IR11 (from −0.3 to −0.4 K. These negative biases may be in part due to the uncertainties in AHI calibration and characterization, although uncertainties in the coefficients of the Community Radiative Transfer Model (CRTM, used to generate the “M” term may also contribute. Work is underway to add AHI analyses in the NOAA Monitoring of IR Clear-Sky Radiances over Oceans for SST (MICROS system and improve AHI BTs by collaborating with the sensor calibration and CRTM teams. The Advanced Baseline Imager (ABI analyses will be also added in MICROS when GOES-R is launched in late 2016 and the ABI IR data become available.

  16. Rapid and Accurate Identification of Animal Species in Natural Leather Goods by Liquid Chromatography/Mass Spectrometry.

    Science.gov (United States)

    Izuchi, Yukari; Takashima, Tsuneo; Hatano, Naoya

    2016-01-01

    The demand for leather goods has grown globally in recent years. Industry revenue is forecast to reach $91.2 billion by 2018. There is an ongoing labelling problem in the leather items market, in that it is currently impossible to identify the species that a given piece of leather is derived from. To address this issue, we developed a rapid and simple method for the specific identification of leather derived from cattle, horses, pigs, sheep, goats, and deer by analysing peptides produced by the trypsin-digestion of proteins contained in leather goods using liquid chromatography/mass spectrometry. We determined species-specific amino acid sequences by liquid chromatography/tandem mass spectrometry analysis using the Mascot software program and demonstrated that collagen α-1(I), collagen α-2(I), and collagen α-1(III) from the dermal layer of the skin are particularly useful in species identification.

  17. Accurate, rapid identification of dislocation lines in coherent diffractive imaging via a min-max optimization formulation

    Science.gov (United States)

    Ulvestad, A.; Menickelly, M.; Wild, S. M.

    2018-01-01

    Defects such as dislocations impact materials properties and their response during external stimuli. Imaging these defects in their native operating conditions to establish the structure-function relationship and, ultimately, to improve performance via defect engineering has remained a considerable challenge for both electron-based and x-ray-based imaging techniques. While Bragg coherent x-ray diffractive imaging (BCDI) is successful in many cases, nuances in identifying the dislocations has left manual identification as the preferred method. Derivative-based methods are also used, but they can be inaccurate and are computationally inefficient. Here we demonstrate a derivative-free method that is both more accurate and more computationally efficient than either derivative- or human-based methods for identifying 3D dislocation lines in nanocrystal images produced by BCDI. We formulate the problem as a min-max optimization problem and show exceptional accuracy for experimental images. We demonstrate a 227x speedup for a typical experimental dataset with higher accuracy over current methods. We discuss the possibility of using this algorithm as part of a sparsity-based phase retrieval process. We also provide MATLAB code for use by other researchers.

  18. New rapid, accurate T2 quantification detects pathology in normal-appearing brain regions of relapsing-remitting MS patients.

    Science.gov (United States)

    Shepherd, Timothy M; Kirov, Ivan I; Charlson, Erik; Bruno, Mary; Babb, James; Sodickson, Daniel K; Ben-Eliezer, Noam

    2017-01-01

    Quantitative T2 mapping may provide an objective biomarker for occult nervous tissue pathology in relapsing-remitting multiple sclerosis (RRMS). We applied a novel echo modulation curve (EMC) algorithm to identify T2 changes in normal-appearing brain regions of subjects with RRMS (N = 27) compared to age-matched controls (N = 38). The EMC algorithm uses Bloch simulations to model T2 decay curves in multi-spin-echo MRI sequences, independent of scanner, and scan-settings. T2 values were extracted from normal-appearing white and gray matter brain regions using both expert manual regions-of-interest and user-independent FreeSurfer segmentation. Compared to conventional exponential T2 modeling, EMC fitting provided more accurate estimations of T2 with less variance across scans, MRI systems, and healthy individuals. Thalamic T2 was increased 8.5% in RRMS subjects (p brain regions of RRMS patients. These presumably capture both axon and myelin changes from inflammation and neurodegeneration. Further, T2 variations between different brain regions of healthy controls may correlate with distinct nervous tissue environments that differ from one another at a mesoscopic length-scale.

  19. Rapid and Accurate Identification by Real-Time PCR of Biotoxin-Producing Dinoflagellates from the Family Gymnodiniaceae

    Directory of Open Access Journals (Sweden)

    Kirsty F. Smith

    2014-03-01

    Full Text Available The identification of toxin-producing dinoflagellates for monitoring programmes and bio-compound discovery requires considerable taxonomic expertise. It can also be difficult to morphologically differentiate toxic and non-toxic species or strains. Various molecular methods have been used for dinoflagellate identification and detection, and this study describes the development of eight real-time polymerase chain reaction (PCR assays targeting the large subunit ribosomal RNA (LSU rRNA gene of species from the genera Gymnodinium, Karenia, Karlodinium, and Takayama. Assays proved to be highly specific and sensitive, and the assay for G. catenatum was further developed for quantification in response to a bloom in Manukau Harbour, New Zealand. The assay estimated cell densities from environmental samples as low as 0.07 cells per PCR reaction, which equated to three cells per litre. This assay not only enabled conclusive species identification but also detected the presence of cells below the limit of detection for light microscopy. This study demonstrates the usefulness of real-time PCR as a sensitive and rapid molecular technique for the detection and quantification of micro-algae from environmental samples.

  20. An accurate and rapid continuous wavelet dynamic time warping algorithm for unbalanced global mapping in nanopore sequencing

    KAUST Repository

    Han, Renmin

    2017-12-24

    Long-reads, point-of-care, and PCR-free are the promises brought by nanopore sequencing. Among various steps in nanopore data analysis, the global mapping between the raw electrical current signal sequence and the expected signal sequence from the pore model serves as the key building block to base calling, reads mapping, variant identification, and methylation detection. However, the ultra-long reads of nanopore sequencing and an order of magnitude difference in the sampling speeds of the two sequences make the classical dynamic time warping (DTW) and its variants infeasible to solve the problem. Here, we propose a novel multi-level DTW algorithm, cwDTW, based on continuous wavelet transforms with different scales of the two signal sequences. Our algorithm starts from low-resolution wavelet transforms of the two sequences, such that the transformed sequences are short and have similar sampling rates. Then the peaks and nadirs of the transformed sequences are extracted to form feature sequences with similar lengths, which can be easily mapped by the original DTW. Our algorithm then recursively projects the warping path from a lower-resolution level to a higher-resolution one by building a context-dependent boundary and enabling a constrained search for the warping path in the latter. Comprehensive experiments on two real nanopore datasets on human and on Pandoraea pnomenusa, as well as two benchmark datasets from previous studies, demonstrate the efficiency and effectiveness of the proposed algorithm. In particular, cwDTW can almost always generate warping paths that are very close to the original DTW, which are remarkably more accurate than the state-of-the-art methods including FastDTW and PrunedDTW. Meanwhile, on the real nanopore datasets, cwDTW is about 440 times faster than FastDTW and 3000 times faster than the original DTW. Our program is available at https://github.com/realbigws/cwDTW.

  1. Using MALDI-TOF mass spectrometry as a rapid and accurate diagnostic tool in infective endocarditis: a case report of a patient with mitral valve infective endocarditis caused by Abiotrophia defectiva

    DEFF Research Database (Denmark)

    Holler, Jon Gitz; Pedersen, Line; Calum, Henrik

    2011-01-01

    A case of infective endocarditis caused by Abiotrophia defectiva is presented. The use of MALDI-TOF mass spectrometry as a rapid and accurate diagnostic tool in infective endocarditis is discussed.......A case of infective endocarditis caused by Abiotrophia defectiva is presented. The use of MALDI-TOF mass spectrometry as a rapid and accurate diagnostic tool in infective endocarditis is discussed....

  2. A reliable and accurate portable device for rapid quantitative estimation of iodine content in different types of edible salt.

    Science.gov (United States)

    Yadav, Kapil; Kumar, Rakesh; Chakrabarty, Arijit; Pandav, Chandrakant S

    2015-01-01

    Continuous monitoring of salt iodization to ensure the success of the Universal Salt Iodization (USI) program can be significantly strengthened by the use of a simple, safe, and rapid method of salt iodine estimation. This study assessed the validity of a new portable device, iCheck Iodine developed by the BioAnalyt GmbH to estimate the iodine content in salt. Validation of the device was conducted in the laboratory of the South Asia regional office of the International Council for Control of Iodine Deficiency Disorders (ICCIDD). The validity of the device was assessed using device specific indicators, comparison of iCheck Iodine device with the iodometric titration, and comparison between iodine estimation using 1 g and 10 g salt by iCheck Iodine using 116 salt samples procured from various small-, medium-, and large-scale salt processors across India. The intra- and interassay imprecision for 10 parts per million (ppm), 30 ppm, and 50 ppm concentrations of iodized salt were 2.8%, 6.1%, and 3.1%, and 2.4%, 2.2%, and 2.1%, respectively. Interoperator imprecision was 6.2%, 6.3%, and 4.6% for the salt with iodine concentrations of 10 ppm, 30 ppm, and 50 ppm respectively. The correlation coefficient between measurements by the two methods was 0.934 and the correlation coefficient between measurements using 1 g of iodized salt and 10 g of iodized salt by the iCheck Iodine device was 0.983. The iCheck Iodine device is reliable and provides a valid method for the quantitative estimation of the iodine content of iodized salt fortified with potassium iodate in the field setting and in different types of salt.

  3. A rapid and accurate approach for prediction of interactomes from co-elution data (PrInCE).

    Science.gov (United States)

    Stacey, R Greg; Skinnider, Michael A; Scott, Nichollas E; Foster, Leonard J

    2017-10-23

    An organism's protein interactome, or complete network of protein-protein interactions, defines the protein complexes that drive cellular processes. Techniques for studying protein complexes have traditionally applied targeted strategies such as yeast two-hybrid or affinity purification-mass spectrometry to assess protein interactions. However, given the vast number of protein complexes, more scalable methods are necessary to accelerate interaction discovery and to construct whole interactomes. We recently developed a complementary technique based on the use of protein correlation profiling (PCP) and stable isotope labeling in amino acids in cell culture (SILAC) to assess chromatographic co-elution as evidence of interacting proteins. Importantly, PCP-SILAC is also capable of measuring protein interactions simultaneously under multiple biological conditions, allowing the detection of treatment-specific changes to an interactome. Given the uniqueness and high dimensionality of co-elution data, new tools are needed to compare protein elution profiles, control false discovery rates, and construct an accurate interactome. Here we describe a freely available bioinformatics pipeline, PrInCE, for the analysis of co-elution data. PrInCE is a modular, open-source library that is computationally inexpensive, able to use label and label-free data, and capable of detecting tens of thousands of protein-protein interactions. Using a machine learning approach, PrInCE offers greatly reduced run time, more predicted interactions at the same stringency, prediction of protein complexes, and greater ease of use over previous bioinformatics tools for co-elution data. PrInCE is implemented in Matlab (version R2017a). Source code and standalone executable programs for Windows and Mac OSX are available at https://github.com/fosterlab/PrInCE , where usage instructions can be found. An example dataset and output are also provided for testing purposes. PrInCE is the first fast and easy

  4. Rapid Preliminary Design of Interplanetary Trajectories Using the Evolutionary Mission Trajectory Generator

    Science.gov (United States)

    Englander, Jacob

    2016-01-01

    This set of tutorial slides is an introduction to the Evolutionary Mission Trajectory Generator (EMTG), NASA Goddard Space Flight Center's autonomous tool for preliminary design of interplanetary missions. This slide set covers the basics of creating and post-processing simple interplanetary missions in EMTG using both high-thrust chemical and low-thrust electric propulsion along with a variety of operational constraints.

  5. Rapid and accurate identification of Mycobacterium tuberculosis complex and common non-tuberculous mycobacteria by multiplex real-time PCR targeting different housekeeping genes.

    Science.gov (United States)

    Nasr Esfahani, Bahram; Rezaei Yazdi, Hadi; Moghim, Sharareh; Ghasemian Safaei, Hajieh; Zarkesh Esfahani, Hamid

    2012-11-01

    Rapid and accurate identification of mycobacteria isolates from primary culture is important due to timely and appropriate antibiotic therapy. Conventional methods for identification of Mycobacterium species based on biochemical tests needs several weeks and may remain inconclusive. In this study, a novel multiplex real-time PCR was developed for rapid identification of Mycobacterium genus, Mycobacterium tuberculosis complex (MTC) and the most common non-tuberculosis mycobacteria species including M. abscessus, M. fortuitum, M. avium complex, M. kansasii, and the M. gordonae in three reaction tubes but under same PCR condition. Genetic targets for primer designing included the 16S rDNA gene, the dnaJ gene, the gyrB gene and internal transcribed spacer (ITS). Multiplex real-time PCR was setup with reference Mycobacterium strains and was subsequently tested with 66 clinical isolates. Results of multiplex real-time PCR were analyzed with melting curves and melting temperature (T (m)) of Mycobacterium genus, MTC, and each of non-tuberculosis Mycobacterium species were determined. Multiplex real-time PCR results were compared with amplification and sequencing of 16S-23S rDNA ITS for identification of Mycobacterium species. Sensitivity and specificity of designed primers were each 100 % for MTC, M. abscessus, M. fortuitum, M. avium complex, M. kansasii, and M. gordonae. Sensitivity and specificity of designed primer for genus Mycobacterium was 96 and 100 %, respectively. According to the obtained results, we conclude that this multiplex real-time PCR with melting curve analysis and these novel primers can be used for rapid and accurate identification of genus Mycobacterium, MTC, and the most common non-tuberculosis Mycobacterium species.

  6. Rapid and Accurate Determination of Lipopolysaccharide O-Antigen Types in Klebsiella pneumoniae with a Novel PCR-Based O-Genotyping Method

    Science.gov (United States)

    Shih, Yun-Jui; Cheong, Cheng-Man; Yi, Wen-Ching

    2015-01-01

    Klebsiella pneumoniae, a Gram-negative bacillus that causes life-threatening infections in both hospitalized patients and ambulatory persons, can be classified into nine lipopolysaccharide (LPS) O-antigen serotypes. The O-antigen type has important clinical and epidemiological significance. However, K. pneumoniae O serotyping is cumbersome, and the reagents are not commercially available. To overcome the limitations of conventional serotyping methods, we aimed to create a rapid and accurate PCR method for K. pneumoniae O genotyping. We sequenced the genetic determinants of LPS O antigen from serotypes O1, O2a, O2ac, O3, O4, O5, O8, O9, and O12. We established a two-step genotyping scheme, based on the two genomic regions associated with O-antigen biosynthesis. The first set of PCR primers, which detects alleles at the wzm-wzt loci of the wb gene cluster, distinguishes between O1/O2, O3, O4, O5, O8, O9, and O12. The second set of PCR primers, which detects alleles at the wbbY region, further differentiates between O1, O2a, and O2ac. We verified the specificity of O genotyping against the O-serotype reference strains. We then tested the sensitivity and specificity of O genotyping in K. pneumoniae, using the 56 K-serotype reference strains with known O serotypes determined by an inhibition enzyme-linked immunosorbent assay (iELISA). There is a very good correlation between the O genotypes and classical O serotypes. Three discrepancies were observed and resolved by nucleotide sequencing—all in favor of O genotyping. The PCR-based O genotyping, which can be easily performed in clinical and research microbiology laboratories, is a rapid and accurate method for determining the LPS O-antigen types of K. pneumoniae isolates. PMID:26719438

  7. Rapid and accurate species and genomic species identification and exhaustive population diversity assessment of Agrobacterium spp. using recA-based PCR.

    Science.gov (United States)

    Shams, M; Vial, L; Chapulliot, D; Nesme, X; Lavire, C

    2013-07-01

    Agrobacteria are common soil bacteria that interact with plants as commensals, plant growth promoting rhizobacteria or alternatively as pathogens. Indigenous agrobacterial populations are composites, generally with several species and/or genomic species and several strains per species. We thus developed a recA-based PCR approach to accurately identify and specifically detect agrobacteria at various taxonomic levels. Specific primers were designed for all species and/or genomic species of Agrobacterium presently known, including 11 genomic species of the Agrobacterium tumefaciens complex (G1-G9, G13 and G14, among which only G2, G4, G8 and G14 still received a Latin epithet: pusense, radiobacter, fabrum and nepotum, respectively), A. larrymoorei, A. rubi, R. skierniewicense, A. sp. 1650, and A. vitis, and for the close relative Allorhizobium undicola. Specific primers were also designed for superior taxa, Agrobacterium spp. and Rhizobiaceace. Primer specificities were assessed with target and non-target pure culture DNAs as well as with DNAs extracted from composite agrobacterial communities. In addition, we showed that the amplicon cloning-sequencing approach used with Agrobacterium-specific or Rhizobiaceae-specific primers is a way to assess the agrobacterial diversity of an indigenous agrobacterial population. Hence, the agrobacterium-specific primers designed in the present study enabled the first accurate and rapid identification of all species and/or genomic species of Agrobacterium, as well as their direct detection in environmental samples. Copyright © 2013 Elsevier GmbH. All rights reserved.

  8. Photogrammetry-Based Head Digitization for Rapid and Accurate Localization of EEG Electrodes and MEG Fiducial Markers Using a Single Digital SLR Camera.

    Science.gov (United States)

    Clausner, Tommy; Dalal, Sarang S; Crespo-García, Maité

    2017-01-01

    The performance of EEG source reconstruction has benefited from the increasing use of advanced head modeling techniques that take advantage of MRI together with the precise positions of the recording electrodes. The prevailing technique for registering EEG electrode coordinates involves electromagnetic digitization. However, the procedure adds several minutes to experiment preparation and typical digitizers may not be accurate enough for optimal source reconstruction performance (Dalal et al., 2014). Here, we present a rapid, accurate, and cost-effective alternative method to register EEG electrode positions, using a single digital SLR camera, photogrammetry software, and computer vision techniques implemented in our open-source toolbox, janus3D. Our approach uses photogrammetry to construct 3D models from multiple photographs of the participant's head wearing the EEG electrode cap. Electrodes are detected automatically or semi-automatically using a template. The rigid facial features from these photo-based models are then surface-matched to MRI-based head reconstructions to facilitate coregistration to MRI space. This method yields a final electrode coregistration error of 0.8 mm, while a standard technique using an electromagnetic digitizer yielded an error of 6.1 mm. The technique furthermore reduces preparation time, and could be extended to a multi-camera array, which would make the procedure virtually instantaneous. In addition to EEG, the technique could likewise capture the position of the fiducial markers used in magnetoencephalography systems to register head position.

  9. Rapid and accurate detection of Escherichia coli growth by fluorescent pH-sensitive organic nanoparticles for high-throughput screening applications.

    Science.gov (United States)

    Si, Yang; Grazon, Chloé; Clavier, Gilles; Rieger, Jutta; Audibert, Jean-Frédéric; Sclavi, Bianca; Méallet-Renault, Rachel

    2016-01-15

    Rapid detection of bacterial growth is an important issue in the food industry and for medical research. Here we present a novel kind of pH-sensitive fluorescent nanoparticles (FANPs) that can be used for the rapid and accurate real-time detection of Escherichia coli growth. These organic particles are designed to be non-toxic and highly water-soluble. Here we show that the coupling of pH sensitive fluoresceinamine to the nanoparticles results in an increased sensitivity to changes in pH within a physiologically relevant range that can be used to monitor the presence of live bacteria. In addition, these FANPs do not influence bacterial growth and are stable over several hours in a complex medium and in the presence of bacteria. The use of these FANPs allows for continuous monitoring of bacterial growth via real-time detection over long time scales in small volumes and can thus be used for the screening of a large number of samples for high-throughput applications such as screening for the presence of antibiotic resistant strains. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. A Rapid, Accurate, and Efficient Method to Map Heavy Metal-Contaminated Soils of Abandoned Mine Sites Using Converted Portable XRF Data and GIS.

    Science.gov (United States)

    Suh, Jangwon; Lee, Hyeongyu; Choi, Yosoon

    2016-12-01

    The use of portable X-ray fluorescence (PXRF) and inductively coupled plasma atomic emission spectrometry (ICP-AES) increases the rapidity and accuracy of soil contamination mapping, respectively. In practice, it is often necessary to repeat the soil contamination assessment and mapping procedure several times during soil management within a limited budget. In this study, we have developed a rapid, inexpensive, and accurate soil contamination mapping method using a PXRF data and geostatistical spatial interpolation. To obtain a large quantity of high quality data for interpolation, in situ PXRF data analyzed at 40 points were transformed to converted PXRF data using the correlation between PXRF and ICP-AES data. The method was applied to an abandoned mine site in Korea to generate a soil contamination map for copper and was validated for investigation speed and prediction accuracy. As a result, regions that required soil remediation were identified. Our method significantly shortened the time required for mapping compared to the conventional mapping method and provided copper concentration estimates with high accuracy similar to those measured by ICP-AES. Therefore, our method is an effective way of mapping soil contamination if we consistently construct a database based on the correlation between PXRF and ICP-AES data.

  11. Accurate Mass Fragment Library for Rapid Analysis of Pesticides on Produce Using Ambient Pressure Desorption Ionization with High-Resolution Mass Spectrometry

    Science.gov (United States)

    Kern, Sara E.; Lin, Lora A.; Fricke, Frederick L.

    2014-08-01

    U.S. food imports have been increasing steadily for decades, intensifying the need for a rapid and sensitive screening technique. A method has been developed that uses foam disks to sample the surface of incoming produce. This work provides complimentary information to the extensive amount of published pesticide fragmentation data collected using LCMS systems (Sack et al. Journal of Agricultural and Food Chemistry, 59, 6383-6411, 2011; Mol et al. Analytical and Bioanalytical Chemistry, 403, 2891-2908, 2012). The disks are directly analyzed using transmission-mode direct analysis in real time (DART) ambient pressure desorption ionization coupled to a high resolution accurate mass-mass spectrometer (HRAM-MS). In order to provide more certainty in the identification of the pesticides detected, a library of accurate mass fragments and isotopes of the protonated parent molecular ion (the [M+H]+) has been developed. The HRAM-MS is equipped with a quadrupole mass filter, providing the capability of "data-dependent" fragmentation, as opposed to "all -ion" fragmentation (where all of the ions enter a collision chamber and are fragmented at once). A temperature gradient for the DART helium stream and multiple collision energies were employed to detect and fragment 164 pesticides of varying chemical classes, sizes, and polarities. The accurate mass information of precursor ([M+H]+ ion) and fragment ions is essential in correctly identifying chemical contaminants on the surface of imported produce. Additionally, the inclusion of isotopes of the [M+H]+ in the database adds another metric to the confirmation process. The fragmentation data were collected using a Q-Exactive mass spectrometer and were added to a database used to process data collected with an Exactive mass spectrometer, an instrument that is more readily available for this screening application. The commodities investigated range from smooth-skinned produce such as apples to rougher surfaces like broccoli. The

  12. A Preliminary Investigation of Rapid Depressurization Phenomena Following a Sudden DLOFC in a VHTR

    Energy Technology Data Exchange (ETDEWEB)

    Richard C. Martineau; Ray A. Berry; Dana A. Knoll

    2009-03-01

    Air ingress has been identified as a potential threat for Very High Temperature gas-cooled Reactors (VHTR). Reactor components constructed of graphite will, at high temperatures, produce exothermic reactions in the presence of oxygen. The danger lies in the possibility of fuel element damage and core structural failure. Previous investigations of air ingress mechanisms have focused on thermal and molecular diffusion, density-driven stratified flow, and natural convection. Here, we investigate the possibility of a rapid ingress of air due to a Taylor wave expansion after a hypothetical sudden loss of coolant accident (LOCA) scenario in a VHTR. Our analysis starts with a one-dimensional shock tube simulation to simply illustrate the development of a Taylor wave with resulting reentrant flow. Then, a simulation is performed of an idealized two-dimensional axisymmetric representation of the lower plenum of General Atomics GT-MHR subjected to a hypothetical catastrophic break of the hot duct. Analysis shows the potential for significant and rapid air ingress into the reactor vessel in the case of a large break in the cooling system.

  13. Rapid, Sensitive, and Accurate Evaluation of Drug Resistant Mutant (NS5A-Y93H Strain Frequency in Genotype 1b HCV by Invader Assay.

    Directory of Open Access Journals (Sweden)

    Satoshi Yoshimi

    Full Text Available Daclatasvir and asunaprevir dual oral therapy is expected to achieve high sustained virological response (SVR rates in patients with HCV genotype 1b infection. However, presence of the NS5A-Y93H substitution at baseline has been shown to be an independent predictor of treatment failure for this regimen. By using the Invader assay, we developed a system to rapidly and accurately detect the presence of mutant strains and evaluate the proportion of patients harboring a pre-treatment Y93H mutation. This assay system, consisting of nested PCR followed by Invader reaction with well-designed primers and probes, attained a high overall assay success rate of 98.9% among a total of 702 Japanese HCV genotype 1b patients. Even in serum samples with low HCV titers, more than half of the samples could be successfully assayed. Our assay system showed a better lower detection limit of Y93H proportion than using direct sequencing, and Y93H frequencies obtained by this method correlated well with those of deep-sequencing analysis (r = 0.85, P <0.001. The proportion of the patients with the mutant strain estimated by this assay was 23.6% (164/694. Interestingly, patients with the Y93H mutant strain showed significantly lower ALT levels (p=8.8 x 10-4, higher serum HCV RNA levels (p=4.3 x 10-7, and lower HCC risk (p=6.9 x 10-3 than those with the wild type strain. Because the method is both sensitive and rapid, the NS5A-Y93H mutant strain detection system established in this study may provide important pre-treatment information valuable not only for treatment decisions but also for prediction of disease progression in HCV genotype 1b patients.

  14. Sensitive, accurate and rapid detection of trace aliphatic amines in environmental samples with ultrasonic-assisted derivatization microextraction using a new fluorescent reagent for high performance liquid chromatography.

    Science.gov (United States)

    Chen, Guang; Liu, Jianjun; Liu, Mengge; Li, Guoliang; Sun, Zhiwei; Zhang, Shijuan; Song, Cuihua; Wang, Hua; Suo, Yourui; You, Jinmao

    2014-07-25

    A new fluorescent reagent, 1-(1H-imidazol-1-yl)-2-(2-phenyl-1H-phenanthro[9,10-d]imidazol-1-yl)ethanone (IPPIE), is synthesized, and a simple pretreatment based on ultrasonic-assisted derivatization microextraction (UDME) with IPPIE is proposed for the selective derivatization of 12 aliphatic amines (C1: methylamine-C12: dodecylamine) in complex matrix samples (irrigation water, river water, waste water, cultivated soil, riverbank soil and riverbed soil). Under the optimal experimental conditions (solvent: ACN-HCl, catalyst: none, molar ratio: 4.3, time: 8 min and temperature: 80°C), micro amount of sample (40 μL; 5mg) can be pretreated in only 10 min, with no preconcentration, evaporation or other additional manual operations required. The interfering substances (aromatic amines, aliphatic alcohols and phenols) get the derivatization yields of impurities. With this UDME-HPLC-FD-MS method, the accuracy (-0.73-2.12%), precision (intra-day: 0.87-3.39%; inter-day: 0.16-4.12%), recovery (97.01-104.10%) and sensitivity were significantly improved. Successful applications in environmental samples demonstrate the superiority of this method in the sensitive, accurate and rapid determination of trace aliphatic amines in micro amount of complex samples. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. A rapid and accurate method for determining protein content in dairy products based on asynchronous-injection alternating merging zone flow-injection spectrophotometry.

    Science.gov (United States)

    Liang, Qin-Qin; Li, Yong-Sheng

    2013-12-01

    An accurate and rapid method and a system to determine protein content using asynchronous-injection alternating merging zone flow-injection spectrophotometry based on reaction between coomassie brilliant blue G250 (CBBG) and protein was established. Main merit of our approach is that it can avoid interferences of other nitric-compounds in samples, such as melamine and urea. Optimized conditions are as follows: Concentrations of CBBG, polyvinyl alcohol (PVA), NaCl and HCl are 150 mg/l, 30 mg/l, 0.1 mol/l and 1.0% (v/v), respectively; volumes of the sample and reagent are 150 μl and 30 μl, respectively; length of a reaction coil is 200 cm; total flow rate is 2.65 ml/min. The linear range of the method is 0.5-15 mg/l (BSA), its detection limit is 0.05 mg/l, relative standard deviation is less than 1.87% (n=11), and analytical speed is 60 samples per hour. Copyright © 2013 Elsevier Ltd. All rights reserved.

  16. Rapid and accurate assessment of GPCR-ligand interactions Using the fragment molecular orbital-based density-functional tight-binding method.

    Science.gov (United States)

    Morao, Inaki; Fedorov, Dmitri G; Robinson, Roger; Southey, Michelle; Townsend-Nicholson, Andrea; Bodkin, Mike J; Heifetz, Alexander

    2017-09-05

    The reliable and precise evaluation of receptor-ligand interactions and pair-interaction energy is an essential element of rational drug design. While quantum mechanical (QM) methods have been a promising means by which to achieve this, traditional QM is not applicable for large biological systems due to its high computational cost. Here, the fragment molecular orbital (FMO) method has been used to accelerate QM calculations, and by combining FMO with the density-functional tight-binding (DFTB) method we are able to decrease computational cost 1000 times, achieving results in seconds, instead of hours. We have applied FMO-DFTB to three different GPCR-ligand systems. Our results correlate well with site directed mutagenesis data and findings presented in the published literature, demonstrating that FMO-DFTB is a rapid and accurate means of GPCR-ligand interactions. © 2017 Authors. Journal of Computational Chemistry Published by Wiley Periodicals, Inc. © 2017 Authors. Journal of Computational Chemistry Published by Wiley Periodicals, Inc.

  17. Enzymic colorimetry-based DNA chip: a rapid and accurate assay for detecting mutations for clarithromycin resistance in the 23S rRNA gene of Helicobacter pylori.

    Science.gov (United States)

    Xuan, Shi-Hai; Zhou, Yu-Gui; Shao, Bo; Cui, Ya-Lin; Li, Jian; Yin, Hong-Bo; Song, Xiao-Ping; Cong, Hui; Jing, Feng-Xiang; Jin, Qing-Hui; Wang, Hui-Min; Zhou, Jie

    2009-11-01

    Macrolide drugs, such as clarithromycin (CAM), are a key component of many combination therapies used to eradicate Helicobacter pylori. However, resistance to CAM is increasing in H. pylori and is becoming a serious problem in H. pylori eradication therapy. CAM resistance in H. pylori is mostly due to point mutations (A2142G/C, A2143G) in the peptidyltransferase-encoding region of the 23S rRNA gene. In this study an enzymic colorimetry-based DNA chip was developed to analyse single-nucleotide polymorphisms of the 23S rRNA gene to determine the prevalence of mutations in CAM-related resistance in H. pylori-positive patients. The results of the colorimetric DNA chip were confirmed by direct DNA sequencing. In 63 samples, the incidence of the A2143G mutation was 17.46 % (11/63). The results of the colorimetric DNA chip were concordant with DNA sequencing in 96.83 % of results (61/63). The colorimetric DNA chip could detect wild-type and mutant signals at every site, even at a DNA concentration of 1.53 x 10(2) copies microl(-1). Thus, the colorimetric DNA chip is a reliable assay for rapid and accurate detection of mutations in the 23S rRNA gene of H. pylori that lead to CAM-related resistance, directly from gastric tissues.

  18. Performance Assessment of GPS-Sensed Precipitable Water Vapor using IGS Ultra-Rapid Orbits: A Preliminary Study in Thailand

    Directory of Open Access Journals (Sweden)

    Yoon-Soo Choi

    2011-01-01

    Full Text Available Precipitable Water Vapor (PWV is a significant variable used for climate change studies. Currently PWV can be derived from the Global Positioning System (GPS observation in addition to the specific instruments such as Radiosondes (RS, Microwave Radiometers (MWR and Meteorological Satellites. To accurately derive PWV from GPS data, long periods of observation time in conjunction with final orbit data have to be applied in the data processing steps. This final orbit data can be acquired from the International GNSS Service (IGS with 13 days latency, which is not practical in climate change studies or meteorological forecasting. Alternatively, real-time ultra-rapid orbits are more suitable for this application but with lower orbit accuracy. It is therefore interesting to evaluate the impact of using different orbits in the estimation of PWV. In this study, data from permanent GPS base stations in Thailand were processed using Bernese 5.0 software to derive near real-time PWV values. Ultra-rapid orbit data have been introduced in the data processing step with different time windows and compared to that using final orbit data with the 24-hr time window. The results have shown that 1.0 mm and 2.9 mm biases can be achieved using 24-hr and 12-hr time windows, respectively. These results therefore address the potential use of ultra-rapid orbits for a near real-time estimation of PWV.

  19. DART-MS for rapid, preliminary screening of urine for DMAA.

    Science.gov (United States)

    Lesiak, Ashton D; Adams, Kendra J; Domin, Marek A; Henck, Colin; Shepard, Jason R E

    2014-01-01

    Dimethylamylamine (DMAA) is a sympathomimetic amine found in weight-loss/workout supplements or used as an appetite suppressant. DMAA is a stimulant that is banned by the World Anti-Doping Agency (WADA). Adverse health effects as well as fatalities have been implicated with its use. Direct analysis in real time mass spectrometry (DART-MS) is an ambient ionization method that was employed to rapidly identify the presence of DMAA in various samples without any extraction or preparations whatsoever. DMAA was first identified in supplements, sampled directly in their solid forms. Furthermore, DMAA was detected directly in urine over 48 h as a means of indicating recent abuse of the substance. DART-MS analysis is instantaneous, and coupled with the high mass accuracy associated with the time-of-flight mass analyzer, results in unequivocal identification of the presence of DMAA. These features demonstrate DART-MS as an attractive potential alternative screening method for the presence of drugs and medications or for toxicological investigations. Copyright © 2013 John Wiley & Sons, Ltd.

  20. A rapid and sensitive HPLC-MS/MS analysis and preliminary pharmacokinetic characterization of sibiricaxanthone F in rats.

    Science.gov (United States)

    Yang, Xiaojuan; Zhou, Guanshen; Zou, Pingping; Ning, Ying; Zan, Ke; Tu, Pengfei; Jiang, Yong

    2011-09-01

    A simple, rapid and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for quantifying sibiricaxanthone F (SF) in rat plasma following oral and intravenous dosings. After addition of the internal standard (IS) kaempferol and the antioxidant, 20% ascorbic acid, plasma samples were precipitated with acetonitrile and separated on an Aglient Zorbax XDB-C(18) column (50 mm × 4.6mm I.D., 2.1 μm) with gradient acetonitrile and water (both containing 0.01% formic acid) as the mobile phase. The detection was performed on a Sciex API 4000 LC-MS/MS with electrospray ionization (ESI) inlet in the negative multiple reaction monitoring (MRM) mode. Good linearity was achieved over the concentration range of 0.5-500.0ng/mL (r>0.996). Intra- and inter-day precisions were less than 7.60%, and accuracy ranged from 97.18% to 99.84%. The lower limit of quantification for SF was 0.5 ng/mL, and analytes were stable under various conditions (during freeze-thaw, at room temperature and under deep-freeze conditions). This validated method was successfully applied to the preliminary pharmacokinetic study of SF in rats for the first time, and the absolute bioavailability of SF was found to be only 0.22 ± 0.15%. Copyright © 2011 Elsevier B.V. All rights reserved.

  1. Comparison of Acoustic Energy Meter (AEM) and Schmidt hammer 'R' for rapid assessment of rock surface hardness: a preliminary assessment from southeast Queensland, Australia

    Science.gov (United States)

    Brook, Martin; Winkler, Stefan

    2015-04-01

    This research focuses on one of the key challenges in geomorphology - quantifying rock surface hardness via in situ measurements, to provide information on rock physical properties. This has been a focus in recent years with the rapid emergence of studies that center on surface and near surface weathering impacts, and rates of material loss. Indeed, a key element to understanding how weathering and erosion processes combine to influence rock surface (and landscape) evolution is the measurement and monitoring of rock surface hardness. We provide results from a preliminary assessment of the applicability of the Acoustic Energy Meter (AEM) to subaerial rock surface hardness, in comparison with an N-Type Schmidt hammer. The AEM apparatus consists of a geophone which is in contact with the rock surface and some electronics. The AEM is held normal to the surface to be tested and the surface is struck with a small hammer (typically 0.75 kg), with the AEM quantifying the decay time of seismically-induced oscillations within the top c. 1-2 m of the rock mass. Previous work using an AEM has focused on measuring roof stability and delamination in South African underground coal, gold and platinum mines, where long AEM reverberation times correlated well with weak rock mass and dense microfracturing. However, the technique has rarely been applied to the assessment of rock surfaces in a subaerial setting. We applied the technique to a range of lithologies at five sites in southeast Queensland in the Brisbane area, each an exposure of phyllite, granite, mudstone, argillite or volcanic tuff. The aims were: (1) quantifying the response of different rock masses to the AEM technique; and (2) assessing the applicability of the AEM as a rapid in situ measure of rock hardness by comparing results with Schmidt hammer 'R' values from the same exposures. Results showed that the AEM is useful in discriminating rock hardness across rocks with different lithological properties. Second, an

  2. Preliminary test of the LFA rapid evaluation of activity in lupus (LFA-REAL): an efficient outcome measure correlates with validated instruments

    OpenAIRE

    Askanase, Anca; Li, Xiaoqing; Pong, Avery; Shum, Katrina; Kamp, Stan; Carthen, Fredonna; Aberle, Teresa; Hanrahan, Leslie; Daly, Paola; Giles, Jon; Merrill, Joan T

    2015-01-01

    Objective Current disease activity measures for systemic lupus erythematosus (SLE) are difficult to score or interpret and problematic for use in clinical practice. Lupus Foundation of America (LFA)-Rapid Evaluation of Activity in Lupus (REAL) is a pilot application composed of anchored visual analogue scores (0?100?mm each) for each organ affected by lupus. This study evaluated the use of LFA-REAL in capturing SLE disease activity. Methods In a preliminary test of LFA-REAL, this simplified, ...

  3. Development of a Rapid and Accurate Identification Method for Citrobacter Species Isolated from Pork Products Using a Matrix-Assisted Laser-Desorption Ionization Time-of-Flight Mass Spectrometry (MALDI-TOF MS).

    Science.gov (United States)

    Kwak, Hye-Lim; Han, Sun-Kyung; Park, Sunghoon; Park, Si Hong; Shim, Jae-Yong; Oh, Mihwa; Ricke, Steven C; Kim, Hae-Yeong

    2015-09-01

    Previous detection methods for Citrobacter are considered time consuming and laborious. In this study, we have developed a rapid and accurate detection method for Citrobacter species in pork products, using matrix-assisted laser desorption ionization time-of-flight (MALDI-TOF) mass spectrometry (MS). A total of 35 Citrobacter strains were isolated from 30 pork products and identified by both MALDI-TOF MS and 16S rRNA gene sequencing approaches. All isolates were identified to the species level by the MALDI-TOF MS, while 16S rRNA gene sequencing results could not discriminate them clearly. These results confirmed that MALDI-TOF MS is a more accurate and rapid detection method for the identification of Citrobacter species.

  4. Immediate-Early Gene Transcriptional Activation in Hippocampus Ca1 and Ca3 Does Not Accurately Reflect Rapid, Pattern Completion-Based Retrieval of Context Memory

    Science.gov (United States)

    Pevzner, Aleksandr; Guzowski, John F.

    2015-01-01

    No studies to date have examined whether immediate-early gene (IEG) activation is driven by context memory recall. To address this question, we utilized the context preexposure facilitation effect (CPFE) paradigm. In CPFE, animals acquire contextual fear conditioning through hippocampus-dependent rapid retrieval of a previously formed contextual…

  5. Rapid and accurate identification of isolates of Candida species by melting peak and melting curve analysis of the internally transcribed spacer region 2 fragment (ITS2-MCA)

    NARCIS (Netherlands)

    Decat, E.; van Mechelen, E.; Saerens, B.; Vermeulen, S.J.T.; Boekhout, T.; de Blaiser, S.; Vaneechoutte, M.; Deschaght, P.

    2013-01-01

    Rapid identification of clinically important yeasts can facilitate the initiation of anti-fungal therapy, since susceptibility is largely species-dependent. We evaluated melting peak and melting curve analysis of the internally transcribed spacer region 2 fragment (ITS2-MCA) as an identification

  6. Blood urea nitrogen to serum creatinine ratio is an accurate predictor of outcome in diarrhea-associated hemolytic uremic syndrome, a preliminary study.

    Science.gov (United States)

    Keenswijk, Werner; Vanmassenhove, Jill; Raes, Ann; Dhont, Evelyn; Vande Walle, Johan

    2017-03-01

    Diarrhea-associated hemolytic uremic syndrome (D+HUS) is a common thrombotic microangiopathy during childhood and early identification of parameters predicting poor outcome could enable timely intervention. This study aims to establish the accuracy of BUN-to-serum creatinine ratio at admission, in addition to other parameters in predicting the clinical course and outcome. Records were searched for children between 1 January 2008 and 1 January 2015 admitted with D+HUS. A complicated course was defined as developing one or more of the following: neurological dysfunction, pancreatitis, cardiac or pulmonary involvement, hemodynamic instability, and hematologic complications while poor outcome was defined by death or development of chronic kidney disease. Thirty-four children were included from which 11 with a complicated disease course/poor outcome. Risk of a complicated course/poor outcome was strongly associated with oliguria (p = 0.000006) and hypertension (p = 0.00003) at presentation. In addition, higher serum creatinine (p = 0.000006) and sLDH (p = 0.02) with lower BUN-to-serum creatinine ratio (p = 0.000007) were significantly associated with development of complications. A BUN-to-sCreatinine ratio ≤40 at admission was a sensitive and highly specific predictor of a complicated disease course/poor outcome. A BUN-to-serum Creatinine ratio can accurately identify children with D+HUS at risk for a complicated course and poor outcome. What is Known: • Oliguria is a predictor of poor long-term outcome in D+HUS What is New: • BUN-to-serum Creatinine ratio at admission is an entirely novel and accurate predictor of poor outcome and complicated clinical outcome in D+HUS • Early detection of the high risk group in D+HUS enabling early treatment and adequate monitoring.

  7. Using modeling, satellite images and existing global datasets for rapid preliminary assessments of renewable energy resources: The case of Mali

    DEFF Research Database (Denmark)

    Nygaard, Ivan; Rasmussen, K.; Badger, Jake

    2010-01-01

    This paper presents a novel approach to the preliminary, low-cost, national-scale mapping of wind energy, solar energy and certain categories of bio-energy resources in developing countries, using Mali as an example. The methods applied make extensive use of satellite remote sensing and meteorolo...

  8. Are Treponema pallidum specific rapid and point-of-care tests for syphilis accurate enough for screening in resource limited settings? Evidence from a meta-analysis.

    Directory of Open Access Journals (Sweden)

    Yalda Jafari

    Full Text Available Rapid and point-of-care (POC tests for syphilis are an invaluable screening tool, yet inadequate evaluation of their diagnostic accuracy against best reference standards limits their widespread global uptake. To fill this gap, a systematic review and meta-analysis was conducted to evaluate the sensitivity and specificity of rapid and POC tests in blood and serum samples against Treponema pallidum (TP specific reference standards.Five electronic databases (1980-2012 were searched, data was extracted from 33 articles, and Bayesian hierarchical models were fit.In serum samples, against a TP specific reference standard point estimates with 95% credible intervals (CrI for the sensitivities of popular tests were: i Determine, 90.04% (80.45, 95.21, ii SD Bioline, 87.06% (75.67, 94.50, iii VisiTect, 85.13% (72.83, 92.57, and iv Syphicheck, 74.48% (56.85, 88.44, while specificities were: i Syphicheck, 99.14% (96.37, 100, ii Visitect, 96.45% (91.92, 99.29, iii SD Bioline, 95.85% (89.89, 99.53, and iv Determine, 94.15% (89.26, 97.66. In whole blood samples, sensitivities were: i Determine, 86.32% (77.26, 91.70, ii SD Bioline, 84.50% (78.81, 92.61, iii Syphicheck, 74.47% (63.94, 82.13, and iv VisiTect, 74.26% (53.62, 83.68, while specificities were: i Syphicheck, 99.58% (98.91, 99.96, ii VisiTect, 99.43% (98.22, 99.98, iii SD Bioline, 97.95%(92.54, 99.33, and iv Determine, 95.85% (92.42, 97.74.Rapid and POC treponemal tests reported sensitivity and specificity estimates comparable to laboratory-based treponemal tests. In resource limited settings, where access to screening is limited and where risk of patients lost to follow up is high, the introduction of these tests has already been shown to improve access to screening and treatment to prevent stillbirths and neonatal mortality due to congenital syphilis. Based on the evidence, it is concluded that rapid and POC tests are useful in resource limited settings with poor access to laboratories or screening

  9. Importance of a Rapid and Accurate Diagnosis inStrongyloides Stercoralisand Human T-Lymphotropic Virus 1 Co-infection: A Case Report and Review of the Literature.

    Science.gov (United States)

    Quintero, Olga; Berini, Carolina A; Waldbaum, Carlos; Avagnina, Alejandra; Juarez, María; Repetto, Silvia; Sorda, Juan; Biglione, Mirna

    2017-01-01

    Strongyloides (S.) stercoralis and Human T-Lymphotropic Virus 1 (HTLV-1) share some endemic regions such as Japan, Jamaica, and South America and are mostly diagnosed elsewhere in immigrants from endemic areas. This co-infection has not been documented in Argentina although both pathogens are endemic in the Northwest. We present a case of S. stercoralis and HTLV-1 co-infection with an initial presentation due to gastrointestinal symptoms which presented neither eosinophilia nor the presence of larvae in stool samples in a non-endemic area for these infections. A young Peruvian woman living in Buenos Aires attended several emergency rooms and finally ended up admitted in a gastroenterology ward due to incoercible vomiting, diarrhea, abdominal pain, fever, and weight loss. Gastrointestinal symptoms started 3 months before she returned to Argentina from a trip to Peru. She presented malnutrition and abdominal distension parameters. HIV-1 and other immunodeficiencies were discarded. The serial coproparasitological test was negative. Computed tomography showed diffuse thickening of duodenal and jejunal walls. At the beginning, vasculitis was suspected and corticosteroid therapy was initiated. The patient worsened rapidly. Skin, new enteral biopsies, and a new set of coproparasitological samples revealed S. stercoralis . Then, HTLV-1 was suspected and infection was confirmed. Ivermectin and albendazole were administrated, until the stool sample remained negative for 2 weeks. Larvae were not observed in fresh stool, Ritchie method, and agar culture 1 week post-treatment. Although she required initial support with parenteral nutrition due to oral intolerance she slowly progressed favorably. It has been highly recommended to include a rapid and sensitive PCR strategy in the algorithm to confirm Strongyloides infection, which has demonstrated to improve early diagnosis in patients at-risk of disseminated strongyloidiasis.

  10. Snow thickness profiling on Antarctic sea ice with GPR—Rapid and accurate measurements with the potential to upscale needles to a haystack

    Science.gov (United States)

    Pfaffhuber, Andreas A.; Lieser, Jan L.; Haas, Christian

    2017-08-01

    Snow thickness on sea ice is a largely undersampled parameter yet of importance for the sea ice mass balance and for satellite-based sea ice thickness estimates and thus our general understanding of global ice volume change. Traditional direct thickness measurements with meter sticks can provide accurate but only spot information, referred to as "needles" due to their pinpoint focus and information, while airborne and satellite remote sensing snow products, referred to as "the haystack," have large uncertainties due to their scale. We demonstrate the remarkable accuracy and applicability of ground-penetrating radar (GPR) snow thickness measurements by comparing them with in situ meter stick data from two field campaigns to Antarctica in late winter/early spring. The efficiency and millimeter-to-centimeter accuracy of GPR enables practitioners to acquire extensive, semiregional data with the potential to upscale needles to the haystack and to potentially calibrate satellite remote sensing products that we confirm to derive roughly 30% of the in situ thickness. We find the radar wave propagation velocity in snow to be rather constant (± 6%), encouraging regional snow thickness surveys. Snow thinner than 10 cm is under the detection limit with the off-the-shelf GPR setup utilized in our study.

  11. Rapid and Accurate Approach for Screening of Microsatellite Unstable Tumours Using Quasimonomorphic Mononucleotide Repeats and Denaturating High Performance Liquid Chromatography (DHPLC

    Directory of Open Access Journals (Sweden)

    Gašper Berginc

    2009-01-01

    Full Text Available MSI analysis is becoming increasingly important for the detection of both hereditary non-polyposis colorectal cancer and sporadic primary colorectal tumours with MSI high phenotype. The Bethesda panel of five microsatellite markers has been proposed to provide uniform criteria for MSI analysis. Here we report on an MSI analysis approach using quasimonomorphic mononucleotide repeats and denaturating high performance liquid chromatography (DHPLC. We analysed 595 newly diagnosed colorectal tumours and 145 normal samples. Microsatellite markers BAT-25, BAT-26, NR-21, NR-22, and NR-27 were amplified in multiplex reaction and analysed using DHPLC and capillary electrophoresis (CE. DHPLC conditions for analysis of MSI multiplex assay were evaluated and tested. Analysis and cross-examination of the results obtained from 96 samples using DHPLC and capillary electrophoresis showed the same sensitivity and specificity of the two approaches for detecting MSI-H tumours. Using our new approach we showed that the tested markers are quasimonomorphic in a Slovenian population, with frequencies of polymorphisms 0.07%, 1.4%, 2.1%, 1.4%, and 1.4% for BAT-25, BAT-26, NR-21, NR-22, and NR-27, respectively. Forty-three (7.2% new MSI-H tumours were identified, of which 84% showed instability in all 5 tested markers. Overall, we developed a high-throughput, robust, accurate and cost-effective approach for the detection of MSI-H tumours.

  12. Rapid genome mapping in nanochannel arrays for highly complete and accurate de novo sequence assembly of the complex Aegilops tauschii genome.

    Directory of Open Access Journals (Sweden)

    Alex R Hastie

    Full Text Available Next-generation sequencing (NGS technologies have enabled high-throughput and low-cost generation of sequence data; however, de novo genome assembly remains a great challenge, particularly for large genomes. NGS short reads are often insufficient to create large contigs that span repeat sequences and to facilitate unambiguous assembly. Plant genomes are notorious for containing high quantities of repetitive elements, which combined with huge genome sizes, makes accurate assembly of these large and complex genomes intractable thus far. Using two-color genome mapping of tiling bacterial artificial chromosomes (BAC clones on nanochannel arrays, we completed high-confidence assembly of a 2.1-Mb, highly repetitive region in the large and complex genome of Aegilops tauschii, the D-genome donor of hexaploid wheat (Triticum aestivum. Genome mapping is based on direct visualization of sequence motifs on single DNA molecules hundreds of kilobases in length. With the genome map as a scaffold, we anchored unplaced sequence contigs, validated the initial draft assembly, and resolved instances of misassembly, some involving contigs <2 kb long, to dramatically improve the assembly from 75% to 95% complete.

  13. Rapid genome mapping in nanochannel arrays for highly complete and accurate de novo sequence assembly of the complex Aegilops tauschii genome.

    Science.gov (United States)

    Hastie, Alex R; Dong, Lingli; Smith, Alexis; Finklestein, Jeff; Lam, Ernest T; Huo, Naxin; Cao, Han; Kwok, Pui-Yan; Deal, Karin R; Dvorak, Jan; Luo, Ming-Cheng; Gu, Yong; Xiao, Ming

    2013-01-01

    Next-generation sequencing (NGS) technologies have enabled high-throughput and low-cost generation of sequence data; however, de novo genome assembly remains a great challenge, particularly for large genomes. NGS short reads are often insufficient to create large contigs that span repeat sequences and to facilitate unambiguous assembly. Plant genomes are notorious for containing high quantities of repetitive elements, which combined with huge genome sizes, makes accurate assembly of these large and complex genomes intractable thus far. Using two-color genome mapping of tiling bacterial artificial chromosomes (BAC) clones on nanochannel arrays, we completed high-confidence assembly of a 2.1-Mb, highly repetitive region in the large and complex genome of Aegilops tauschii, the D-genome donor of hexaploid wheat (Triticum aestivum). Genome mapping is based on direct visualization of sequence motifs on single DNA molecules hundreds of kilobases in length. With the genome map as a scaffold, we anchored unplaced sequence contigs, validated the initial draft assembly, and resolved instances of misassembly, some involving contigs <2 kb long, to dramatically improve the assembly from 75% to 95% complete.

  14. An Immunoassay to Rapidly Measure Acetaminophen Protein Adducts Accurately Identifies Patients With Acute Liver Injury or Failure.

    Science.gov (United States)

    Roberts, Dean W; Lee, William M; Hinson, Jack A; Bai, Shasha; Swearingen, Christopher J; Stravitz, R Todd; Reuben, Adrian; Letzig, Lynda; Simpson, Pippa M; Rule, Jody; Fontana, Robert J; Ganger, Daniel; Reddy, K Rajender; Liou, Iris; Fix, Oren; James, Laura P

    2017-04-01

    A rapid and reliable point-of-care assay to detect acetaminophen protein adducts in the serum of patients with acute liver injury could improve diagnosis and management. AcetaSTAT is a competitive immunoassay used to measure acetaminophen protein adducts formed by toxic metabolites in serum samples from patients. We compared the accuracy of AcetaSTAT vs high-pressure liquid chromatography with electrochemical detection (HPLC-EC; a sensitive and specific quantitative analytic assay) to detect acetaminophen protein adducts. We collected serum samples from 19 healthy individuals (no liver injury, no recent acetaminophen use), 29 patients without acetaminophen-associated acute liver injury, and 33 patients with acetaminophen-associated acute liver injury participating in the Acute Liver Failure Study Group registry. Each serum sample was analyzed by AcetaSTAT (reported as test band amplitude) and HPLC-EC (the reference standard). We also collected data on patient age, sex, weight, level of alanine aminotransferase on test day and peak values, concentration of acetaminophen, diagnoses (by site investigator and causality review committee), and outcome after 21 days. Differences between groups were analyzed using the Fisher exact test for categoric variables and the Kruskal-Wallis test or rank-sum test for continuous variables. AcetaSTAT discriminated between patients with and without acetaminophen-associated acute liver injury; the median AcetaSTAT test band amplitude for patients with acetaminophen-associated acute liver injury was 584 (range, 222-1027) vs 3678 (range, 394-8289) for those without (P acetaminophen-associated acute liver injury with 100% sensitivity, 86.2% specificity, a positive predictive value of 89.2%, and a negative predictive value of 100%. Results from AcetaSTAT were positive in 4 subjects who received a causality review committee diagnosis of non-acetaminophen-associated acute liver injury; HPLC-EC and biochemical profiles were consistent with

  15. A new general and rapid method for investigating hot corrosion: preliminary tests on electrodes for molten carbonate fuel cells

    Energy Technology Data Exchange (ETDEWEB)

    Griffiths, T.R. [Dept. of Chemistry, Univ. of Leeds, Leeds (United Kingdom); Volkovich, V.A. [Dept. of Rare Metals, Ural State Technical Univ. - UPI, Ekaterinburg (Russian Federation)

    2004-07-01

    With the increase and improvement in corrosion resistant alloys, coatings and surface treatments, the ability to test and predict their long-term behaviour to oxidation under hot corrosion conditions, within a reasonable time period, becomes diminished. Peroxide and superoxide ions are the most active oxidisers and we have established a means for generating them in significant concentrations in molten carbonates. This thus has the potential for enabling accelerated hot corrosion studies and we here describe the technique and report preliminary studies on the nickel and nickel oxide electrodes used in molten carbonate fuel cells. Further applications are expected to follow. (orig.)

  16. Dual rapid lateral flow immunoassay fingerstick wholeblood testing for syphilis and HIV infections is acceptable and accurate, Port-au-Prince, Haiti.

    Science.gov (United States)

    Bristow, Claire C; Severe, Linda; Pape, Jean William; Javanbakht, Marjan; Lee, Sung-Jae; Comulada, Warren Scott; Klausner, Jeffrey D

    2016-06-18

    Dual rapid tests for HIV and syphilis infections allow for detection of HIV infection and syphilis at the point-of-care. Those tests have been evaluated in laboratory settings and show excellent performance but have not been evaluated in the field. We evaluated the field performance of the SD BIOLINE HIV/Syphilis Duo test in Port-au-Prince, Haiti using whole blood fingerprick specimens. GHESKIO (Haitian Study Group for Kaposi's Sarcoma and Opportunistic Infections) clinic attendees 18 years of age or older were invited to participate. Venipuncture blood specimens were used for reference testing with standard commercially available tests for HIV and syphilis in Haiti. The sensitivity and specificity of the Duo test compared to the reference standard were calculated. The exact binomial method was used to determine 95 % confidence intervals (CI). Of 298 study participants, 237 (79.5 %) were female, of which 49 (20.7 %) were pregnant. For the HIV test component, the sensitivity and specificity were 99.2 % (95 % CI: 95.8 %, 100 %) and 97.0 % (95 % CI: 93.2 %, 99.0 %), respectively; and for the syphilis component were 96.5 % (95 % CI: 91.2 %, 99.0 %) and 90.8 % (95 % CI: 85.7 %, 94.6 %), respectively. In pregnant women, the sensitivity and specificity of the HIV test component were 93.3 % (95 % CI: 68.0 %, 99.8 %) and 94.1 % (95 % CI: 80.3 %, 99.3 %), respectively; and for the syphilis component were 100 % (95 % CI:81.5 %, 100 %) and 96.8 % (95 % CI:83.3 %, 99.9 %), respectively. The Standard Diagnostics BIOLINE HIV/Syphilis Duo dual test performed well in a field setting in Haiti and should be considered for wider use.

  17. Development of a Rapid Immunodiagnostic Test for Pork Components in Raw Beef and Chicken Meats: a Preliminary Study

    Directory of Open Access Journals (Sweden)

    S. N. Depamede

    2011-08-01

    Full Text Available A rapid immunodiagnostic test that provides visual evidence of the presence of pork components in raw beef and chicken meats was developed. Colloidal gold was prepared and conjugated with anti-Swine IgG polyclonal antibody. Immunochromatographic test strips were produced, and then were used to test laboratory adulterated raw meat samples. The samples consisted adulteration meat, immunodiagnostic, pork, rapid test of pork-in-beef, or pork-in-chicken at 1/0; 1/100; 1/1,000; 1/5,000; 1/10,000 (w/w adulteration levels that were extracted in phosphate-buffered saline. Raw beef and chicken meats without pork were included as controls. Analysis was completed in 10 min. Detection limit was 1/5,000 (w/w, although 1/10,000 was also observed. This immunodiagnostic tests can be conveniently applied to detect low levels of pork components in raw beef and chicken meat products. For the commercial purposes, further studies need to be carried out.

  18. Preliminary Study of Fiber Optic Multi-Cardiac-Marker Biosensing System for Rapid Coronary Heart Disease Diagnosis and Prognosis

    Science.gov (United States)

    Tang, Liang; Kang, Kyung A.

    A fiber-optic biosensing system for the simultaneous quantification of four cardiac markers is currently under development, in our research group, for rapid coronary disease diagnosis and prognosis. As an initial effort, four individual BNP, cTnI, MG, and CRP sensors were developed. The sensors showed excellent performance in quantifying these cardiac markers in their clinically significant ranges within 15 minutes, at a S/N ratio of 25-50. The cross-reactivity of the four sensors was also found to be negligible. A mixture of four AF647-2o Mabs has shown only a slight interference to the four sensors, indicating that the mixture can be applied through a multi-sensing unit for simultaneous detection with an easier operation.

  19. Preliminary Clinical Application of Removable Partial Denture Frameworks Fabricated Using Computer-Aided Design and Rapid Prototyping Techniques.

    Science.gov (United States)

    Ye, Hongqiang; Ning, Jing; Li, Man; Niu, Li; Yang, Jian; Sun, Yuchun; Zhou, Yongsheng

    The aim of this study was to explore the application of computer-aided design and rapid prototyping (CAD/RP) for removable partial denture (RPD) frameworks and evaluate the fitness of the technique for clinical application. Three-dimensional (3D) images of dentition defects were obtained using a lab scanner. The RPD frameworks were designed using commercial dental software and manufactured using selective laser melting (SLM). A total of 15 cases of RPD prostheses were selected, wherein each patient received two types of RPD frameworks, prepared by CAD/RP and investment casting. Primary evaluation of the CAD/RP framework was performed by visual inspection. The gap between the occlusal rest and the relevant rest seat was then replaced using silicone, and the specimens were observed and measured. Paired t test was used to compare the average thickness and distributed thickness between the CAD/RP and investment casting frameworks. Analysis of variance test was used to compare the difference in thickness among different zones. The RPD framework was designed and directly manufactured using the SLM technique. CAD/RP frameworks may meet the clinical requirements with satisfactory retention and stability and no undesired rotation. Although the average gap between the occlusal rest and the corresponding rest seat of the CAD/RP frameworks was slightly larger than that of the investment casting frameworks (P < .05), it was acceptable for clinical application. RPD frameworks can be designed and fabricated directly using digital techniques with acceptable results in clinical application.

  20. A rapid, accurate and sensitive method with the new stable isotopic tags based on microwave-assisted dispersive liquid-liquid microextraction and its application to the determination of hydroxyl UV filters in environmental water samples.

    Science.gov (United States)

    Li, Xiu; Chen, Guang; Liu, Jianjun; Liu, Yuxia; Zhao, Xianen; Cao, Ziping; Xia, Lian; Li, Guoliang; Sun, Zhiwei; Zhang, Shijuan; Wang, Hua; You, Jinmao

    2017-05-15

    A rapid, accurate and sensitive method, using the stable isotope labeling (SIL), microwave-assisted dispersive liquid-liquid micro extraction (MADLLME) and the ultra-high performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS), was developed and validated for the determination of hydroxyl UV Filters in environmental water samples. A pair of new isotopic tags D0-/D3-1-methylindole-3-acetic acid (D0-/D3-MIAA) is synthesized, with which a simple yet efficient pretreatment MADLLME-SIL is developed. Under the optimized conditions (80℃, 240W, 180s), the sample pretreatment including analyte extraction, pre-concentration and isotope labeling can be finished conveniently in only 9min. D0-/D3-MIAA labeling improves the chromatographic retention by strengthening the hydrophobicity and enhances the MS response for 3-4 orders of magnitude. Excellent linearity is established by the H/D ratios of 1/10-10/1 with the correlation coefficients >0.9990. The quite low detection limits (0.54-1.79ng/L) are achieved, ensuring the trace detection. This method is successfully applied to a series of environmental water samples. The recoveries (93.2%~103.5%) are significantly improved and the analysis time is largely reduced (filters in water samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Preliminary test of the LFA rapid evaluation of activity in lupus (LFA-REAL): an efficient outcome measure correlates with validated instruments.

    Science.gov (United States)

    Askanase, Anca; Li, Xiaoqing; Pong, Avery; Shum, Katrina; Kamp, Stan; Carthen, Fredonna; Aberle, Teresa; Hanrahan, Leslie; Daly, Paola; Giles, Jon; Merrill, Joan T

    2015-01-01

    Current disease activity measures for systemic lupus erythematosus (SLE) are difficult to score or interpret and problematic for use in clinical practice. Lupus Foundation of America (LFA)-Rapid Evaluation of Activity in Lupus (REAL) is a pilot application composed of anchored visual analogue scores (0-100 mm each) for each organ affected by lupus. This study evaluated the use of LFA-REAL in capturing SLE disease activity. In a preliminary test of LFA-REAL, this simplified, organ-based system was compared with the most widely used outcome measures in clinical trials, the British Isles Lupus Assessment Group 2004 Index (BILAG), the SLE Disease Activity Index (SLEDAI) and the Safety of Estrogens in Lupus Erythematosus National Assessment (SELENA) SLEDAI Physician's Global Assessment (SS-PGA). The level of agreement was analysed using Spearman rank correlations. 91 patients with SLE with mild to severe disease activity were evaluated, their median SLEDAI score was 4.0 (range 0-28) and BILAG score 8.0 (0-32). The median SS-PGA was 38 mm (4-92) versus the total REAL 50 mm (0-268), which expands in range by additive organ scores. Thirty-three patients had moderate to severe disease activity (≥1.5 on SS-PGA landmarks). The median SS-PGA score of this group was 66 mm (50-92) versus median REAL score of 100 mm (59-268), confirming ability to detect a wider distribution of scores at higher disease activity. Total REAL correlated with SLEDAI, BILAG and SS-PGA (correlation coefficient=0.816, 0.933 and 0.903, respectively; pexercise, there were strong correlations between LFA-REAL and validated lupus disease activity indices. Further development may be valuable for consistent scoring in clinical trials, grading optimal assessment of change in disease activity and reliable monitoring of patients in practice.

  2. Novel, In-House, SYBR Green Based One-Step rRT-PCR: Rapid and Accurate Diagnosis of Crimean-Congo Hemorrhagic Fever Virus in Suspected Patients From Iran.

    Science.gov (United States)

    Zahraei, Bentolhoda; Hashemzadeh, Mohammad Sadegh; Najarasl, Mohammad; Zahiriyeganeh, Samaneh; Tat, Mahdi; Metanat, Maliheh; Sepehri Rad, Nahid; Khansari-Nejad, Behzad; Zafari, Ehsan; Sharti, Mojtaba; Dorostkar, Ruhollah

    2016-01-01

    The Crimean-Congo hemorrhagic fever (CCHF) virus causes severe disease in humans, with a high mortality rate. Since, there is no approved vaccine or specific treatment for CCHF, an early and accurate diagnosis, as well as reliable surveillance, is essential for case management and patient improvement. For this research, our aim was to evaluate the application of a novel SYBR Green based one-step real-time reverse-transcriptase polymerase chain reaction (rRT-PCR) assay for the in-house diagnosis of the CCHF virus. In this experimental study, the highly conserved S-region sequence of the CCHF viral genome was first adapted from GenBank, and the specific primers targeting this region were designed. Then, the viral RNA was extracted from 75 serum samples from different patients in eastern Iran. The sensitivity and specificity of the primers were also evaluated in positive serum samples previously confirmed to have the CCHF virus, by this one-step rRT-PCR assay, as well as a DNA sequencing analysis. From a total of 75 suspected serum samples, 42 were confirmed to be positive for CCHF virus, with no false-positives detected by the sequencing results. After 40 amplification cycles, the melting curve analysis revealed a mean melting temperature (Tm) of 86.5 ± 0.6°C (quite different from those of the primer-dimers), and the positive samples showed only a small variation in the parameters. In all of the positive samples, the predicted length of 420 bp was confirmed by electrophoresis. Moreover, the sensitivity test showed that this assay can detect less than 20 copies of viral RNA per reaction. This study showed that this novel one-step rRT-PCR assay is a rapid, reliable, repeatable, specific, sensitive, and simple tool for the detection of the CCHF virus.

  3. Development of Dual TaqMan Based One-Step rRT-PCR Assay Panel for Rapid and Accurate Diagnostic Test of MERS-CoV: A Novel Human Coronavirus, Ahead of Hajj Pilgrimage.

    Science.gov (United States)

    Hashemzadeh, Mohammad Sadegh; Rasouli, Rahimeh; Zahraei, Bentolhoda; Izadi, Morteza; Tat, Mahdi; Saadat, Seyed Hassan; Najarasl, Mohammad; Khansari Nejad, Behzad; Dorostkar, Ruhollah

    2016-11-01

    Coronaviruses (CoVs) are large ribonucleic acid (RNA) viruses causing primarily respiratory disease in humans. A novel human coronavirus, subsequently named middle east respiratory syndrome coronavirus (MERS-CoV), was first reported in Saudi Arabia in September of 2012. With increasing numbers of infections and deaths from MERS-CoV, development of a rapid and reliable kit was crucial to prevent further spread of MERS-CoV. In this study, we present two real-time reverse-transcription polymerase chain reaction (rRT-PCR) assays for in-house rapid and sensitive diagnostic testing of MERS-CoV, detecting the regions upstream of the envelope gene (upE) and open reading frame (ORF) 1b, respectively, for initial screening and final confirmation of MERS-CoV infection, as recommended by the world health organization (WHO). In this experimental study, acquiring patient samples was difficult; thus, according to WHO recommendations and standard protocols, we synthesized RNA sequences of upE and ORF1b genes as the template signatures and TaqMan based-diagnostic rRT-PCR assays were carried out using these synthetic genes for detection of MERS-CoV. In this research, we also inaugurated a cell-free system to transcribe these RNA sequences using the DNA templates synthesized. The upE and ORF1b based one-step rRT-PCR assays were optimized by testing several times via different synthetic RNAs, and validation results were highly successful. The sensitivity obtained for upE was fewer than ten copies of RNA template per reaction and for ORF1b was 50 or fewer copies per reaction. This study showed that the developed rRT-PCR assays are rapid, reliable, reproducible, specific, sensitive, and simple tools for detection of MERS-CoV. Finally, a kit consisting of two assay signatures and controls was assembled, which can be distributed to public health laboratories in Iran to support international MERS-CoV surveillance and public health response.

  4. A rapid and fully automatic method for the accurate determination of a wide carbon-chain range of per- and polyfluoroalkyl substances (C4-C18) in human serum.

    Science.gov (United States)

    Gao, Ke; Gao, Yan; Li, Yili; Fu, Jianjie; Zhang, Aiqian

    2016-11-04

    A rapid and fully automatic method for determining 21 per- and polyfluoroalkyl substances (with carbon chains ranging from C4 to C18, including 13 PFCAs, 5 PFSAs, 2 Cl-PFESAs, and PFOSA) in human serum samples was developed. The HPLC parameters, Turboflow column, mobile phase, sample injection volume, loading flow rate, and sample cleanup and elution time were optimized. 25μL serum sample was directly injected into the developed on-line Turboflow SPE HPLC-MS/MS system for analysis after dilution. Matrix effects were corrected due to the matrix removal efficiency of the Turboflow column and sufficient types of internal isotope standards that were used. The established method showed a good linearity (r2>0.99), rapid processing time (20min per sample), satisfactory recoveries (matrix spiked recoveries range from 84.6% to 114%) and precision (intra-day and inter-day RSDs ranged from 1.5% to 9.2% and from 1.1% to 7.0%, respectively). The limits of detection (LODs) of the 21 analyzed PFASs were between 0.008 and 0.19ngmL-1. The LODs of short- and long-chain PFASs, such as PFBA, PFPeA, PFHxDA, and PFODA, were 0.008, 0.022, 0.15 and 0.19ngmL-1, respectively; the spiked recoveries of these PFASs were 101, 105, 87.1, and 85.8%, respectively. Both the LODs and recoveries were better than previous studies. Further, serum PFASs concentrations detected by the presented on-line SPE method were consistent with the traditional off-line SPE method (r: 0.98-0.99), which verified the accuracy and applicability of the present method. The method shows good practical prospects in the analysis of trace per- and polyfluoroalkyl substances in human serum. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Grading More Accurately

    Science.gov (United States)

    Rom, Mark Carl

    2011-01-01

    Grades matter. College grading systems, however, are often ad hoc and prone to mistakes. This essay focuses on one factor that contributes to high-quality grading systems: grading accuracy (or "efficiency"). I proceed in several steps. First, I discuss the elements of "efficient" (i.e., accurate) grading. Next, I present analytical results…

  6. The identification of fall history using maximal and rapid isometric torque characteristics of the hip extensors in healthy, recreationally active elderly females: a preliminary investigation.

    Science.gov (United States)

    Palmer, Ty B; Thiele, Ryan M; Williams, Katherine B; Adams, Bailey M; Akehi, Kazuma; Smith, Douglas B; Thompson, Brennan J

    2015-08-01

    Maximal and rapid torque characteristics of the hip extensor muscles play an important role in fall prevention and other balance-related performances; however, few studies have investigated the ability of these variables at identifying fall-history status in healthy, recreationally active elderly adults. This study aimed to examine the effectiveness of maximal and rapid isometric torque characteristics of the hip extensor muscles to differentiate between healthy, recreationally active elderly females with (fallers) and without (non-fallers) a history a falls. Six elderly female fallers (mean ± SD: age = 73 ± 7 year; mass = 68 ± 16 kg; height = 160 ± 5 cm) and nine elderly female non-fallers (age = 71 ± 7 year; mass = 66 ± 16 kg; height = 157 ± 6 cm) performed two isometric maximal voluntary contractions (MVCs) of the hip extensor muscles. Peak torque (PT) and absolute and relative rate of torque development (RTD) at the early (0-50 ms) and late (100-200 ms) phases of muscle contraction were examined during each MVC. Absolute and relative RTD at 0-50 ms were greater (P = 0.039 and 0.011, respectively) in the non-fallers compared to the fallers. However, no group-related differences (P = 0.160-0.573) were observed for PT nor absolute and relative RTD at 100-200 ms. Early rapid strength production of the hip extensor muscles may be a sensitive and effective measure for discriminating between elderly females of different fall histories. These findings may provide important insight regarding implications for the assessment of fall risk and in the development of proper training programs aimed at minimizing the occurrence of falls and other balance-related injuries in the elderly.

  7. Rapid and Accurate Idea Transfer: Presenting Ideas with Concept Maps

    Science.gov (United States)

    2008-07-30

    50 PowerPoint slides, in thum bnail...numerically inferior to the rest of the population of the state, in a non-dominant position , whose members being citizens of a state, possess ethnic beliefs...acceptable of these definitions is that minority people, who are in a subordinate position due to their numbers, have to be different by "ethnic or

  8. BIOACCESSIBILITY TESTS ACCURATELY ESTIMATE ...

    Science.gov (United States)

    Hazards of soil-borne Pb to wild birds may be more accurately quantified if the bioavailability of that Pb is known. To better understand the bioavailability of Pb to birds, we measured blood Pb concentrations in Japanese quail (Coturnix japonica) fed diets containing Pb-contaminated soils. Relative bioavailabilities were expressed by comparison with blood Pb concentrations in quail fed a Pb acetate reference diet. Diets containing soil from five Pb-contaminated Superfund sites had relative bioavailabilities from 33%-63%, with a mean of about 50%. Treatment of two of the soils with P significantly reduced the bioavailability of Pb. The bioaccessibility of the Pb in the test soils was then measured in six in vitro tests and regressed on bioavailability. They were: the “Relative Bioavailability Leaching Procedure” (RBALP) at pH 1.5, the same test conducted at pH 2.5, the “Ohio State University In vitro Gastrointestinal” method (OSU IVG), the “Urban Soil Bioaccessible Lead Test”, the modified “Physiologically Based Extraction Test” and the “Waterfowl Physiologically Based Extraction Test.” All regressions had positive slopes. Based on criteria of slope and coefficient of determination, the RBALP pH 2.5 and OSU IVG tests performed very well. Speciation by X-ray absorption spectroscopy demonstrated that, on average, most of the Pb in the sampled soils was sorbed to minerals (30%), bound to organic matter 24%, or present as Pb sulfate 18%. Ad

  9. Groundwater recharge: Accurately representing evapotranspiration

    CSIR Research Space (South Africa)

    Bugan, Richard DH

    2011-09-01

    Full Text Available Groundwater recharge is the basis for accurate estimation of groundwater resources, for determining the modes of water allocation and groundwater resource susceptibility to climate change. Accurate estimations of groundwater recharge with models...

  10. Is Near-Patient Monitoring with Haemoglobinometer as accurate as ...

    African Journals Online (AJOL)

    In the surgical patient, intravascular volume and haemoglobin may change rapidly and frequent rapid assessment of patient status is indicated. We investigated whether near-patient monitoring using a haemoglobinometer was as accurate as a laboratory spectrophotometry in determining haemoglobin concentration.

  11. Rapid reduction in blood flow to the rat ventral prostate gland after castration: preliminary evidence that androgens influence prostate size by regulating blood flow to the prostate gland and prostatic endothelial cell survival.

    Science.gov (United States)

    Shabsigh, A; Chang, D T; Heitjan, D F; Kiss, A; Olsson, C A; Puchner, P J; Buttyan, R

    1998-08-01

    Androgenic steroids regulate the development and size of the mammalian prostate gland. The mechanism(s) for this growth control might involve a direct effect on prostate cell proliferation and survival as well as more complex effects on the tissue environment supporting nourishment and oxygenation. In this study, we evaluated an animal model of androgen action on the prostate, the rat ventral prostate gland, to determine whether acute androgen withdrawal, by means of castration, might alter the primary blood flow to the prostate gland and for the effects of castration on prostatic endothelial cell viability. Groups of rats studied included intact control males, males that had been surgically castrated, or males that received a sham-surgical castration. Relative blood flow (RBF) to the rat ventral prostate glands and rat bladders were measured at 18 and 24 hr after castration or sham castration using a fluorescent microsphere infusion technique. Thin sections from fixed and embedded rat ventral prostate glands obtained from unoperated or 12-hr castrated rats were analyzed by the TUNEL immunostaining technique to microscopically identify and quantify apoptotic epithelial, stromal, and endothelial cells. RBF to the rat ventral prostate was reduced by 38%, at 18 hr after castration when compared with intact or sham-operated rats and by 45% at 24 hr after castration (P=0.038 unoperated/0.025 sham operated). In contrast, RBF to the bladder was not significantly different between any of the groups in the 24-hr castrate experiment. TUNEL staining analysis of ventral prostate tissues obtained from 12-hr castrated rats showed only rare TUNEL-positive epithelial cells similar to the control tissue but significantly increased TUNEL labeling for endothelial and other ventral prostate stromal cells. Castration resulted in a rapid and significant reduction of blood flow to the mature rat ventral prostate gland that was not seen in the bladder. This reduction precedes the

  12. NNLOPS accurate associated HW production

    CERN Document Server

    Astill, William; Re, Emanuele; Zanderighi, Giulia

    2016-01-01

    We present a next-to-next-to-leading order accurate description of associated HW production consistently matched to a parton shower. The method is based on reweighting events obtained with the HW plus one jet NLO accurate calculation implemented in POWHEG, extended with the MiNLO procedure, to reproduce NNLO accurate Born distributions. Since the Born kinematics is more complex than the cases treated before, we use a parametrization of the Collins-Soper angles to reduce the number of variables required for the reweighting. We present phenomenological results at 13 TeV, with cuts suggested by the Higgs Cross Section Working Group.

  13. Molecular Tools for Rapid and Accurate Detection of Black Truffle (Tuber melanosporum Vitt. in Inoculated Nursery Plants and Commercial Plantations in Chile Uso de Marcadores Moleculares para la Detección Rápida y Precisa de Trufa Negra (Tuber melanosporum Vitt. en Plantas de Vivero y Plantaciones Comerciales de Chile

    Directory of Open Access Journals (Sweden)

    Cecilia Cordero

    2011-09-01

    Full Text Available Truffle (Tuber melanosporum Vitt. culture is an agroforestry sector in Chile of increasing interest due to the high prices that truffles fetch in the national market and the recent evidence that its commercial production is possible in Chilean climatic and soil conditions. In this study, the efficiency of three methods of DNA extraction from a mix of 5 g of soil and roots from both nursery and field plants of Quercus ilex L. mycorrhized with T. melanosporum were evaluated, and a simple and reproducible protocol was established. Detection of T. melanosporum was performed by the technique of cleaved amplified polymorphic sequence (CAPS from amplicons generated with the primers ADL1 (5´-GTAACGATAAAGGCCATCTATAGG-3´ and ADL3 (5´-CGTTTTTCCTGAACTCTTCATCAC-3`, where a restriction fragment of 160 bp specific for T. melanosporum was generated, which allows the discrimination of this species from the rest of the species belonging to the Tuber sp. genus. Direct detection of T. melanosporum in one step was also obtained by polymerase chain reaction (PCR from total DNA isolated from mycorrhized roots and with the primers ITSML (5´-TGGCCATGTGTCAGATTTAGTA-3´ and ITSLNG (5´-TGATATGCTTAAGTTCAGCGGG-3´, generating a single amplicon of 440 bp. The molecular detection of T. melanosporum by the methods presented here will allow the rapid and accurate detection of mycorrhization of trees, both under nursery and field conditions. This technology will also provide more security to farmers by controlling the quality of the mycorrhized trees they will plant and also by following the mycorrhization status of established orchards.

  14. Accurate phase-shift velocimetry in rock.

    Science.gov (United States)

    Shukla, Matsyendra Nath; Vallatos, Antoine; Phoenix, Vernon R; Holmes, William M

    2016-06-01

    Spatially resolved Pulsed Field Gradient (PFG) velocimetry techniques can provide precious information concerning flow through opaque systems, including rocks. This velocimetry data is used to enhance flow models in a wide range of systems, from oil behaviour in reservoir rocks to contaminant transport in aquifers. Phase-shift velocimetry is the fastest way to produce velocity maps but critical issues have been reported when studying flow through rocks and porous media, leading to inaccurate results. Combining PFG measurements for flow through Bentheimer sandstone with simulations, we demonstrate that asymmetries in the molecular displacement distributions within each voxel are the main source of phase-shift velocimetry errors. We show that when flow-related average molecular displacements are negligible compared to self-diffusion ones, symmetric displacement distributions can be obtained while phase measurement noise is minimised. We elaborate a complete method for the production of accurate phase-shift velocimetry maps in rocks and low porosity media and demonstrate its validity for a range of flow rates. This development of accurate phase-shift velocimetry now enables more rapid and accurate velocity analysis, potentially helping to inform both industrial applications and theoretical models. Copyright © 2016. Published by Elsevier Inc.

  15. DOMAC: an accurate, hybrid protein domain prediction server

    OpenAIRE

    Cheng, Jianlin

    2007-01-01

    Protein domain prediction is important for protein structure prediction, structure determination, function annotation, mutagenesis analysis and protein engineering. Here we describe an accurate protein domain prediction server (DOMAC) combining both template-based and ab initio methods. The preliminary version of the server was ranked among the top domain prediction servers in the seventh edition of Critical Assessment of Techniques for Protein Structure Prediction (CASP7), 2006. DOMAC server...

  16. Accurate measurements in volume data

    NARCIS (Netherlands)

    Oliván Bescós, J.; Bosma, Marco; Smit, Jaap; Mun, S.K.

    2001-01-01

    An algorithm for very accurate visualization of an iso- surface in a 3D medical dataset has been developed in the past few years. This technique is extended in this paper to several kinds of measurements in which exact geometric information of a selected iso-surface is used to derive volume, length,

  17. Toward Accurate and Quantitative Comparative Metagenomics.

    Science.gov (United States)

    Nayfach, Stephen; Pollard, Katherine S

    2016-08-25

    Shotgun metagenomics and computational analysis are used to compare the taxonomic and functional profiles of microbial communities. Leveraging this approach to understand roles of microbes in human biology and other environments requires quantitative data summaries whose values are comparable across samples and studies. Comparability is currently hampered by the use of abundance statistics that do not estimate a meaningful parameter of the microbial community and biases introduced by experimental protocols and data-cleaning approaches. Addressing these challenges, along with improving study design, data access, metadata standardization, and analysis tools, will enable accurate comparative metagenomics. We envision a future in which microbiome studies are replicable and new metagenomes are easily and rapidly integrated with existing data. Only then can the potential of metagenomics for predictive ecological modeling, well-powered association studies, and effective microbiome medicine be fully realized. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. When Is Network Lasso Accurate?

    Directory of Open Access Journals (Sweden)

    Alexander Jung

    2018-01-01

    Full Text Available The “least absolute shrinkage and selection operator” (Lasso method has been adapted recently for network-structured datasets. In particular, this network Lasso method allows to learn graph signals from a small number of noisy signal samples by using the total variation of a graph signal for regularization. While efficient and scalable implementations of the network Lasso are available, only little is known about the conditions on the underlying network structure which ensure network Lasso to be accurate. By leveraging concepts of compressed sensing, we address this gap and derive precise conditions on the underlying network topology and sampling set which guarantee the network Lasso for a particular loss function to deliver an accurate estimate of the entire underlying graph signal. We also quantify the error incurred by network Lasso in terms of two constants which reflect the connectivity of the sampled nodes.

  19. Accurate Accident Reconstruction in VANET

    OpenAIRE

    Kopylova, Yuliya; Farkas, Csilla; Xu, Wenyuan

    2011-01-01

    Part 9: Short Papers; International audience; We propose a forensic VANET application to aid an accurate accident reconstruction. Our application provides a new source of objective real-time data impossible to collect using existing methods. By leveraging inter-vehicle communications, we compile digital evidence describing events before, during, and after an accident in its entirety. In addition to sensors data and major components’ status, we provide relative positions of all vehicles involv...

  20. Accurate determination of antenna directivity

    DEFF Research Database (Denmark)

    Dich, Mikael

    1997-01-01

    The derivation of a formula for accurate estimation of the total radiated power from a transmitting antenna for which the radiated power density is known in a finite number of points on the far-field sphere is presented. The main application of the formula is determination of directivity from power......-pattern measurements. The derivation is based on the theory of spherical wave expansion of electromagnetic fields, which also establishes a simple criterion for the required number of samples of the power density. An array antenna consisting of Hertzian dipoles is used to test the accuracy and rate of convergence...

  1. Accurate Modeling of Advanced Reflectarrays

    DEFF Research Database (Denmark)

    Zhou, Min

    of the incident field, the choice of basis functions, and the technique to calculate the far-field. Based on accurate reference measurements of two offset reflectarrays carried out at the DTU-ESA Spherical NearField Antenna Test Facility, it was concluded that the three latter factors are particularly important...... to the conventional phase-only optimization technique (POT), the geometrical parameters of the array elements are directly optimized to fulfill the far-field requirements, thus maintaining a direct relation between optimization goals and optimization variables. As a result, better designs can be obtained compared...... using the GDOT to demonstrate its capabilities. To verify the accuracy of the GDOT, two offset contoured beam reflectarrays that radiate a high-gain beam on a European coverage have been designed and manufactured, and subsequently measured at the DTU-ESA Spherical Near-Field Antenna Test Facility...

  2. The Accurate Particle Tracer Code

    CERN Document Server

    Wang, Yulei; Qin, Hong; Yu, Zhi

    2016-01-01

    The Accurate Particle Tracer (APT) code is designed for large-scale particle simulations on dynamical systems. Based on a large variety of advanced geometric algorithms, APT possesses long-term numerical accuracy and stability, which are critical for solving multi-scale and non-linear problems. Under the well-designed integrated and modularized framework, APT serves as a universal platform for researchers from different fields, such as plasma physics, accelerator physics, space science, fusion energy research, computational mathematics, software engineering, and high-performance computation. The APT code consists of seven main modules, including the I/O module, the initialization module, the particle pusher module, the parallelization module, the field configuration module, the external force-field module, and the extendible module. The I/O module, supported by Lua and Hdf5 projects, provides a user-friendly interface for both numerical simulation and data analysis. A series of new geometric numerical methods...

  3. Rapid Airplane Parametric Input Design (RAPID)

    Science.gov (United States)

    Smith, Robert E.

    1995-01-01

    ADIFOR to the grid generation program. The output of ADIFOR is a new source code containing the old code plus expressions for derivatives of specified dependent variables (grid coordinates) with respect to specified independent variables (design parameters). The RAPID methodology and software provide a means of rapidly defining numerical prototypes, grids, and grid sensitivity of a class of airplane configurations. This technology and software is highly useful for CFD research for preliminary design and optimization processes.

  4. The accurate particle tracer code

    Science.gov (United States)

    Wang, Yulei; Liu, Jian; Qin, Hong; Yu, Zhi; Yao, Yicun

    2017-11-01

    The Accurate Particle Tracer (APT) code is designed for systematic large-scale applications of geometric algorithms for particle dynamical simulations. Based on a large variety of advanced geometric algorithms, APT possesses long-term numerical accuracy and stability, which are critical for solving multi-scale and nonlinear problems. To provide a flexible and convenient I/O interface, the libraries of Lua and Hdf5 are used. Following a three-step procedure, users can efficiently extend the libraries of electromagnetic configurations, external non-electromagnetic forces, particle pushers, and initialization approaches by use of the extendible module. APT has been used in simulations of key physical problems, such as runaway electrons in tokamaks and energetic particles in Van Allen belt. As an important realization, the APT-SW version has been successfully distributed on the world's fastest computer, the Sunway TaihuLight supercomputer, by supporting master-slave architecture of Sunway many-core processors. Based on large-scale simulations of a runaway beam under parameters of the ITER tokamak, it is revealed that the magnetic ripple field can disperse the pitch-angle distribution significantly and improve the confinement of energetic runaway beam on the same time.

  5. Rapid Assessment of Aircraft Structural Topologies for Multidisciplinary Optimization and Weight Estimation

    Science.gov (United States)

    Samareh, Jamshid A.; Sensmeier, mark D.; Stewart, Bret A.

    2006-01-01

    Algorithms for rapid generation of moderate-fidelity structural finite element models of air vehicle structures to allow more accurate weight estimation earlier in the vehicle design process have been developed. Application of these algorithms should help to rapidly assess many structural layouts before the start of the preliminary design phase and eliminate weight penalties imposed when actual structure weights exceed those estimated during conceptual design. By defining the structural topology in a fully parametric manner, the structure can be mapped to arbitrary vehicle configurations being considered during conceptual design optimization. Recent enhancements to this approach include the porting of the algorithms to a platform-independent software language Python, and modifications to specifically consider morphing aircraft-type configurations. Two sample cases which illustrate these recent developments are presented.

  6. Effective and Accurate Colormap Selection

    Science.gov (United States)

    Thyng, K. M.; Greene, C. A.; Hetland, R. D.; Zimmerle, H.; DiMarco, S. F.

    2016-12-01

    Science is often communicated through plots, and design choices can elucidate or obscure the presented data. The colormap used can honestly and clearly display data in a visually-appealing way, or can falsely exaggerate data gradients and confuse viewers. Fortunately, there is a large resource of literature in color science on how color is perceived which we can use to inform our own choices. Following this literature, colormaps can be designed to be perceptually uniform; that is, so an equally-sized jump in the colormap at any location is perceived by the viewer as the same size. This ensures that gradients in the data are accurately percieved. The same colormap is often used to represent many different fields in the same paper or presentation. However, this can cause difficulty in quick interpretation of multiple plots. For example, in one plot the viewer may have trained their eye to recognize that red represents high salinity, and therefore higher density, while in the subsequent temperature plot they need to adjust their interpretation so that red represents high temperature and therefore lower density. In the same way that a single Greek letter is typically chosen to represent a field for a paper, we propose to choose a single colormap to represent a field in a paper, and use multiple colormaps for multiple fields. We have created a set of colormaps that are perceptually uniform, and follow several other design guidelines. There are 18 colormaps to give options to choose from for intuitive representation. For example, a colormap of greens may be used to represent chlorophyll concentration, or browns for turbidity. With careful consideration of human perception and design principles, colormaps may be chosen which faithfully represent the data while also engaging viewers.

  7. Rapid Prototyping

    Science.gov (United States)

    1999-01-01

    Javelin, a Lone Peak Engineering Inc. Company has introduced the SteamRoller(TM) System as a commercial product. The system was designed by Javelin during a Phase II NASA funded small commercial product. The purpose of the invention was to allow automated-feed of flexible ceramic tapes to the Laminated Object Manufacturing rapid prototyping equipment. The ceramic material that Javelin was working with during the Phase II project is silicon nitride. This engineered ceramic material is of interest for space-based component.

  8. Note: Fast, small, accurate 90° rotator for a polarizer.

    Science.gov (United States)

    Shelton, David P; O'Donnell, William M; Norton, James L

    2011-03-01

    A permanent magnet stepper motor is modified to hold a dichroic polarizer inside the motor. Rotation of the polarizer by 90° ± 0.04° is accomplished within 80 ms. This device is used for measurements of the intensity ratio for two orthogonal linear polarized components of a light beam. The two selected polarizations can be rapidly alternated to allow for signal drift compensation, and the two selected polarizations are accurately orthogonal.

  9. Efficient and Accurate Computational Framework for Injector Design and Analysis Project

    Data.gov (United States)

    National Aeronautics and Space Administration — CFD codes used to simulate upper stage expander cycle engines are not adequately mature to support design efforts. Rapid and accurate simulations require more...

  10. 38 CFR 4.46 - Accurate measurement.

    Science.gov (United States)

    2010-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2010-07-01 2010-07-01 false Accurate measurement. 4... RATING DISABILITIES Disability Ratings The Musculoskeletal System § 4.46 Accurate measurement. Accurate measurement of the length of stumps, excursion of joints, dimensions and location of scars with respect to...

  11. Preliminary Monthly Climatological Summaries

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Preliminary Local Climatological Data, recorded since 1970 on Weather Burean Form 1030 and then National Weather Service Form F-6. The preliminary climate data pages...

  12. Rapid Detection of Pathogens

    Energy Technology Data Exchange (ETDEWEB)

    David Perlin

    2005-08-14

    Pathogen identification is a crucial first defense against bioterrorism. A major emphasis of our national biodefense strategy is to establish fast, accurate and sensitive assays for diagnosis of infectious diseases agents. Such assays will ensure early and appropriate treatment of infected patients. Rapid diagnostics can also support infection control measures, which monitor and limit the spread of infectious diseases agents. Many select agents are highly transmissible in the early stages of disease, and it is critical to identify infected patients and limit the risk to the remainder of the population and to stem potential panic in the general population. Nucleic acid-based molecular approaches for identification overcome many of the deficiencies associated with conventional culture methods by exploiting both large- and small-scale genomic differences between organisms. PCR-based amplification of highly conserved ribosomal RNA (rRNA) genes, intergenic sequences, and specific toxin genes is currently the most reliable approach for bacterial, fungal and many viral pathogenic agents. When combined with fluorescence-based oligonucleotide detection systems, this approach provides real-time, quantitative, high fidelity analysis capable of single nucleotide allelic discrimination (4). These probe systems offer rapid turn around time (<2 h) and are suitable for high throughput, automated multiplex operations that are critical for clinical diagnostic laboratories. In this pilot program, we have used molecular beacon technology invented at the Public health Research Institute to develop a new generation of molecular probes to rapidly detect important agents of infectious diseases. We have also developed protocols to rapidly extract nucleic acids from a variety of clinical specimen including and blood and tissue to for detection in the molecular assays. This work represented a cooperative research development program between the Kramer-Tyagi/Perlin labs on probe development

  13. Accurate Biomass Estimation via Bayesian Adaptive Sampling

    Science.gov (United States)

    Wheeler, K.; Knuth, K.; Castle, P.

    2005-12-01

    and IKONOS imagery and the 3-D volume estimates. The combination of these then allow for a rapid and hopefully very accurate estimation of biomass.

  14. Preliminary Analysis of Photoreading

    Science.gov (United States)

    McNamara, Danielle S.

    2000-01-01

    The purpose of this project was to provide a preliminary analysis of a reading strategy called PhotoReading. PhotoReading is a technique developed by Paul Scheele that claims to increase reading rate to 25,000 words per minute (Scheele, 1993). PhotoReading itself involves entering a "relaxed state" and looking at, but not reading, each page of a text for a brief moment (about I to 2 seconds). While this technique has received attention in the popular press, there had been no objective examinations of the technique's validity. To examine the effectiveness of PhotoReading, the principal investigator (i.e., trainee) participated in a PhotoReading workshop to learn the technique. Parallel versions of two standardized and three experimenter-created reading comprehension tests were administered to the trainee and an expert user of the PhotoReading technique to compare the use of normal reading strategies and the PhotoReading technique by both readers. The results for all measures yielded no benefits of using the PhotoReading technique. The extremely rapid reading rates claimed by PhotoReaders were not observed; indeed, the reading rates were generally comparable to those for normal reading. Moreover, the PhotoReading expert generally showed an increase in reading time when using the PhotoReading technique in comparison to when using normal reading strategies to process text. This increase in reading time when PhotoReading was accompanied by a decrease in text comprehension.

  15. Compact and Accurate Turbocharger Modelling for Engine Control

    DEFF Research Database (Denmark)

    Sorenson, Spencer C; Hendricks, Elbert; Magnússon, Sigurjón

    2005-01-01

    (Engine Control Unit) as a table. This method uses a great deal of memory space and often requires on-line interpolation and thus a large amount of CPU time. In this paper a more compact, accurate and rapid method of dealing with the compressor modelling problem is presented and is applicable to all......With the current trend towards engine downsizing, the use of turbochargers to obtain extra engine power has become common. A great díffuculty in the use of turbochargers is in the modelling of the compressor map. In general this is done by inserting the compressor map directly into the engine ECU...

  16. Accurate registration of temporal CT images for pulmonary nodules detection

    Science.gov (United States)

    Yan, Jichao; Jiang, Luan; Li, Qiang

    2017-02-01

    Interpretation of temporal CT images could help the radiologists to detect some subtle interval changes in the sequential examinations. The purpose of this study was to develop a fully automated scheme for accurate registration of temporal CT images for pulmonary nodule detection. Our method consisted of three major registration steps. Firstly, affine transformation was applied in the segmented lung region to obtain global coarse registration images. Secondly, B-splines based free-form deformation (FFD) was used to refine the coarse registration images. Thirdly, Demons algorithm was performed to align the feature points extracted from the registered images in the second step and the reference images. Our database consisted of 91 temporal CT cases obtained from Beijing 301 Hospital and Shanghai Changzheng Hospital. The preliminary results showed that approximately 96.7% cases could obtain accurate registration based on subjective observation. The subtraction images of the reference images and the rigid and non-rigid registered images could effectively remove the normal structures (i.e. blood vessels) and retain the abnormalities (i.e. pulmonary nodules). This would be useful for the screening of lung cancer in our future study.

  17. Accurate test limits under prescribed consumer risk

    NARCIS (Netherlands)

    Albers, Willem/Wim; Arts, G.R.J.; Kallenberg, W.C.M.

    1997-01-01

    Measurement errors occurring during inspection of manufactured parts force producers to replace specification limits by slightly more strict test limits. Here accurate test limits are presented which maximize the yield while limiting the fraction of defectives reaching the consumer.

  18. Accurate atmospheric parameters at moderate resolution using spectral indices: Preliminary application to the marvels survey

    Energy Technology Data Exchange (ETDEWEB)

    Ghezzi, Luan; Da Costa, Luiz N.; Maia, Marcio A. G.; Ogando, Ricardo L. C. [Observatório Nacional, Rua Gal. José Cristino 77, Rio de Janeiro, RJ 20921-400 (Brazil); Dutra-Ferreira, Letícia; Lorenzo-Oliveira, Diego; Porto de Mello, Gustavo F.; Santiago, Basílio X. [Laboratório Interinstitucional de e-Astronomia - LIneA, Rua Gal. José Cristino 77, Rio de Janeiro, RJ 20921-400 (Brazil); De Lee, Nathan [Department of Physics and Geology, Northern Kentucky University, Highland Heights, KY 41099 (United States); Lee, Brian L.; Ge, Jian [Department of Astronomy, University of Florida, 211 Bryant Space Science Center, Gainesville, FL 32611-2055 (United States); Wisniewski, John P. [H. L. Dodge Department of Physics and Astronomy, University of Oklahoma, 440 West Brooks St Norman, OK 73019 (United States); González Hernández, Jonay I. [Instituto de Astrofísica de Canarias (IAC), E-38205 La Laguna, Tenerife (Spain); Stassun, Keivan G.; Cargile, Phillip; Pepper, Joshua [Department of Physics and Astronomy, Vanderbilt University, Nashville, TN 37235 (United States); Fleming, Scott W. [Space Telescope Science Institute - STScI, 3700 San Martin Drive, Baltimore, MD 21218 (United States); Schneider, Donald P.; Mahadevan, Suvrath [Department of Astronomy and Astrophysics, The Pennsylvania State University, University Park, PA 16802 (United States); Wang, Ji, E-mail: luan@linea.gov.br [Department of Astronomy, Yale University, New Haven, CT 06511 (United States); and others

    2014-12-01

    Studies of Galactic chemical, and dynamical evolution in the solar neighborhood depend on the availability of precise atmospheric parameters (effective temperature T {sub eff}, metallicity [Fe/H], and surface gravity log g) for solar-type stars. Many large-scale spectroscopic surveys operate at low to moderate spectral resolution for efficiency in observing large samples, which makes the stellar characterization difficult due to the high degree of blending of spectral features. Therefore, most surveys employ spectral synthesis, which is a powerful technique, but relies heavily on the completeness and accuracy of atomic line databases and can yield possibly correlated atmospheric parameters. In this work, we use an alternative method based on spectral indices to determine the atmospheric parameters of a sample of nearby FGK dwarfs and subgiants observed by the MARVELS survey at moderate resolving power (R ∼ 12,000). To avoid a time-consuming manual analysis, we have developed three codes to automatically normalize the observed spectra, measure the equivalent widths of the indices, and, through a comparison of those with values calculated with predetermined calibrations, estimate the atmospheric parameters of the stars. The calibrations were derived using a sample of 309 stars with precise stellar parameters obtained from the analysis of high-resolution FEROS spectra, permitting the low-resolution equivalent widths to be directly related to the stellar parameters. A validation test of the method was conducted with a sample of 30 MARVELS targets that also have reliable atmospheric parameters derived from the high-resolution spectra and spectroscopic analysis based on the excitation and ionization equilibria method. Our approach was able to recover the parameters within 80 K for T {sub eff}, 0.05 dex for [Fe/H], and 0.15 dex for log g, values that are lower than or equal to the typical external uncertainties found between different high-resolution analyses. An additional test was performed with a subsample of 138 stars from the ELODIE stellar library, and the literature atmospheric parameters were recovered within 125 K for T {sub eff}, 0.10 dex for [Fe/H], and 0.29 dex for log g. These precisions are consistent with or better than those provided by the pipelines of surveys operating with similar resolutions. These results show that the spectral indices are a competitive tool to characterize stars with intermediate resolution spectra.

  19. Accurate Atmospheric Parameters at Moderate Resolution Using Spectral Indices: Preliminary Application to the MARVELS Survey

    Science.gov (United States)

    Ghezzi, Luan; Dutra-Ferreira, Letícia; Lorenzo-Oliveira, Diego; Porto de Mello, Gustavo F.; Santiago, Basílio X.; De Lee, Nathan; Lee, Brian L.; da Costa, Luiz N.; Maia, Marcio A. G.; Ogando, Ricardo L. C.; Wisniewski, John P.; González Hernández, Jonay I.; Stassun, Keivan G.; Fleming, Scott W.; Schneider, Donald P.; Mahadevan, Suvrath; Cargile, Phillip; Ge, Jian; Pepper, Joshua; Wang, Ji; Paegert, Martin

    2014-12-01

    Studies of Galactic chemical, and dynamical evolution in the solar neighborhood depend on the availability of precise atmospheric parameters (effective temperature T eff, metallicity [Fe/H], and surface gravity log g) for solar-type stars. Many large-scale spectroscopic surveys operate at low to moderate spectral resolution for efficiency in observing large samples, which makes the stellar characterization difficult due to the high degree of blending of spectral features. Therefore, most surveys employ spectral synthesis, which is a powerful technique, but relies heavily on the completeness and accuracy of atomic line databases and can yield possibly correlated atmospheric parameters. In this work, we use an alternative method based on spectral indices to determine the atmospheric parameters of a sample of nearby FGK dwarfs and subgiants observed by the MARVELS survey at moderate resolving power (R ~ 12,000). To avoid a time-consuming manual analysis, we have developed three codes to automatically normalize the observed spectra, measure the equivalent widths of the indices, and, through a comparison of those with values calculated with predetermined calibrations, estimate the atmospheric parameters of the stars. The calibrations were derived using a sample of 309 stars with precise stellar parameters obtained from the analysis of high-resolution FEROS spectra, permitting the low-resolution equivalent widths to be directly related to the stellar parameters. A validation test of the method was conducted with a sample of 30 MARVELS targets that also have reliable atmospheric parameters derived from the high-resolution spectra and spectroscopic analysis based on the excitation and ionization equilibria method. Our approach was able to recover the parameters within 80 K for T eff, 0.05 dex for [Fe/H], and 0.15 dex for log g, values that are lower than or equal to the typical external uncertainties found between different high-resolution analyses. An additional test was performed with a subsample of 138 stars from the ELODIE stellar library, and the literature atmospheric parameters were recovered within 125 K for T eff, 0.10 dex for [Fe/H], and 0.29 dex for log g. These precisions are consistent with or better than those provided by the pipelines of surveys operating with similar resolutions. These results show that the spectral indices are a competitive tool to characterize stars with intermediate resolution spectra. Based on observations obtained with the 2.2 m MPG telescope at the European Southern Observatory (La Silla, Chile), under the agreement ESO-Observatório Nacional/MCT, and the Sloan Digital Sky Survey, which is owned and operated by the Astrophysical Research Consortium.

  20. Rapid Polymer Sequencer

    Science.gov (United States)

    Stolc, Viktor (Inventor); Brock, Matthew W (Inventor)

    2013-01-01

    Method and system for rapid and accurate determination of each of a sequence of unknown polymer components, such as nucleic acid components. A self-assembling monolayer of a selected substance is optionally provided on an interior surface of a pipette tip, and the interior surface is immersed in a selected liquid. A selected electrical field is impressed in a longitudinal direction, or in a transverse direction, in the tip region, a polymer sequence is passed through the tip region, and a change in an electrical current signal is measured as each polymer component passes through the tip region. Each of the measured changes in electrical current signals is compared with a database of reference electrical change signals, with each reference signal corresponding to an identified polymer component, to identify the unknown polymer component with a reference polymer component. The nanopore preferably has a pore inner diameter of no more than about 40 nm and is prepared by heating and pulling a very small section of a glass tubing.

  1. Rapid and Accurate Assembly Method for a New Laue Lens Prototype

    DEFF Research Database (Denmark)

    Wade, Colin; Barriere, Nicolas; Hanlon, Lorraine

    2015-01-01

    The Laue lens is a technology for gamma-ray astrophysics whereby gamma-rays of particular energies can be focused by a suitable arrangement of crystals. The Laue lens assembly station at UC Berkeley was used to build a technological demonstrator addressing the key issues of crystal mounting speed...

  2. Implementing an accurate and rapid sparse sampling approach for low-dose atomic resolution STEM imaging

    Science.gov (United States)

    Kovarik, L.; Stevens, A.; Liyu, A.; Browning, N. D.

    2016-10-01

    While aberration correction for scanning transmission electron microscopes (STEMs) dramatically increased the spatial resolution obtainable in the images of materials that are stable under the electron beam, the practical resolution of many STEM images is now limited by the sample stability rather than the microscope. To extract physical information from the images of beam sensitive materials, it is becoming clear that there is a critical dose/dose-rate below which the images can be interpreted as representative of the pristine material, while above it the observation is dominated by beam effects. Here, we describe an experimental approach for sparse sampling in the STEM and in-painting image reconstruction in order to reduce the electron dose/dose-rate to the sample during imaging. By characterizing the induction limited rise-time and hysteresis in the scan coils, we show that a sparse line-hopping approach to scan randomization can be implemented that optimizes both the speed of the scan and the amount of the sample that needs to be illuminated by the beam. The dose and acquisition time for the sparse sampling is shown to be effectively decreased by at least a factor of 5× relative to conventional acquisition, permitting imaging of beam sensitive materials to be obtained without changing the microscope operating parameters. The use of sparse line-hopping scan to acquire STEM images is demonstrated with atomic resolution aberration corrected the Z-contrast images of CaCO3, a material that is traditionally difficult to image by TEM/STEM because of dosage issues.

  3. Highly Accurate Antibody Assays for Early and Rapid Detection of Tuberculosis in African and Asian Elephants

    Science.gov (United States)

    Tuberculosis (TB) in elephants is a re-emerging zoonotic disease caused primarily by Mycobacterium tuberculosis. Current methods for screening and diagnosis rely on trunk wash culture, which has serious limitations due to low test sensitivity, slow turn-around time, and variable sample quality. Inn...

  4. Application of the antibiotic batumin for accurate and rapid identification of staphylococcal small colony variants

    Directory of Open Access Journals (Sweden)

    Churkina Larisa N

    2012-07-01

    Full Text Available Abstract Background Staphylococcus aureus is a major human pathogen causing significant morbidity and mortality. The S. aureus colonies in osteomyelitis, in patients with cystic fibrosis and patients with endoprosthesis rejection frequently have an atypical morphology, i.e. staphylococcal small-colony variants, which form a naturally occurring subpopulation of clinically important staphylococci. Identification of these small colony variants is difficult, because of the loss of typical phenotypic characteristics of these variants. We wanted to improve and simplify the diagnosis of staphylococcal infection using a diagnostic preparation, consisting of 5 μg batumin paper disks. Batumin possesses a unique selective activity against all studied Staphylococcus spp., whereas all other species tested thus far are batumin resistant. We assessed the efficacy of the batumin diagnostic preparation to identify staphylococcal small colony variants, isolated from osteomyelitis patients. Findings With the batumin diagnostic preparation, all 30 tested staphylococcal small-colony variants had a growth inhibition zone around the disk of minimum 25 mm, accordant with the inhibition zones of the parent strains, isolated from the same patients. Conclusions The batumin diagnostic preparation correctly identified the small-colony variants of S. aureus, S. haemolyticus and S. epidermidis as belonging to the genus Staphylococcus, which differ profoundly from parental strains and are difficult to identify with standard methods. Identification of staphylococcal small-colony variants with the batumin diagnostic preparation is technically simple and can facilitate practical laboratory work.

  5. Rapid and accurate assembly method for a new Laue lens prototype

    Science.gov (United States)

    Wade, Colin; Barrière, Nicolas; Hanlon, Lorraine; Boggs, Steven E.; Brejnholt, Nicolai F.; Massahi, Sonny; Tomsick, John A.; von Ballmoos, Peter

    2015-09-01

    The Laue lens is a technology for gamma-ray astrophysics whereby gamma-rays of particular energies can be focused by a suitable arrangement of crystals. The Laue lens assembly station at UC Berkeley was used to build a technological demonstrator addressing the key issues of crystal mounting speed, crystal position and orientation accuracy, and crystal reflectivity. The new prototype is a lens segment containing a total of 48 5 x 5 mm2 crystals - 36 Iron and 12 Aluminium. The segment is composed of 8 partial rings, each of which is aligned to diffract an energy between 95 and 130 keV from a source at 12:5m with a focal length of 1:5 m.

  6. Apparatus for use in rapid and accurate controlled-potential coulometric analysis

    Science.gov (United States)

    Frazzini, Thomas L.; Holland, Michael K.; Pietri, Charles E.; Weiss, Jon R.

    1981-01-01

    An apparatus for controlled-potential coulometric analysis of a solution includes a cell to contain the solution to be analyzed and a plurality of electrodes to contact the solution in the cell. Means are provided to stir the solution and to control the atmosphere above it. A potentiostat connected to the electrodes controls potential differences among the electrodes. An electronic circuit connected to the potentiostat provides analog-to-digital conversion and displays a precise count of charge transfer during a desired chemical process. This count provides a measure of the amount of an unknown substance in the solution.

  7. Rapid accurate analysis of metal (oxide)-on-silica catalysts by atomic absorption spectrometry

    NARCIS (Netherlands)

    Jütte, B.A.H.G.; Heikamp, A.; Agterdenbos, J.

    1979-01-01

    The catalysts, which contain 10–60% copper, chromium, nickel and silicon, are decomposed in sealed Teflon-lined vessels and analyzed by atomic absorption spectrometry. Matrix matching and bracketing standards are applied. The RSD of a single determination is about 1% for all components.

  8. Accurate and rapid species typing from cutaneous and mucocutaneous leishmaniasis lesions of the New World.

    Science.gov (United States)

    Fraga, Jorge; Veland, Nicolas; Montalvo, Ana M; Praet, Nicolas; Boggild, Andrea K; Valencia, Braulio M; Arévalo, Jorge; Llanos-Cuentas, Alejandro; Dujardin, Jean-Claude; Van der Auwera, Gert

    2012-10-01

    The heat-shock protein 70 gene (hsp70) has been exploited for Leishmania species identification in the Old and New World, using polymerase chain reaction (PCR) followed by restriction fragment length polymorphism analysis. Three new Leishmania-specific hsp70 PCRs were recently described, and we applied 2 of these on 89 clinical samples from a total of 73 Peruvian patients with either cutaneous or mucocutaneous leishmaniasis. The new PCRs on average showed a 2- to 3-fold improved sensitivity in the tested sample types (lesion biopsies, aspirates, and scrapings), for both genus detection and species typing, and were most successful in biopsies. Leishmania braziliensis, L. peruviana, and L. guyanensis were encountered. About one third of the L. braziliensis parasites contained 2 hsp70 alleles. This study is a paradigm for the implementation of a globally applicable upgraded tool for the identification of Leishmania directly on human specimens from cutaneous and mucocutaneous lesions in the New World. Copyright © 2012 Elsevier Inc. All rights reserved.

  9. Implementing an Accurate and Rapid Sparse Sampling Approach for Low-Dose Atomic Resolution STEM Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kovarik, Libor; Stevens, Andrew J.; Liyu, Andrey V.; Browning, Nigel D.

    2016-10-17

    Aberration correction for scanning transmission electron microscopes (STEM) has dramatically increased spatial image resolution for beam-stable materials, but it is the sample stability rather than the microscope that often limits the practical resolution of STEM images. To extract physical information from images of beam sensitive materials it is becoming clear that there is a critical dose/dose-rate below which the images can be interpreted as representative of the pristine material, while above it the observation is dominated by beam effects. Here we describe an experimental approach for sparse sampling in the STEM and in-painting image reconstruction in order to reduce the electron dose/dose-rate to the sample during imaging. By characterizing the induction limited rise-time and hysteresis in scan coils, we show that sparse line-hopping approach to scan randomization can be implemented that optimizes both the speed of the scan and the amount of the sample that needs to be illuminated by the beam. The dose and acquisition time for the sparse sampling is shown to be effectively decreased by factor of 5x relative to conventional acquisition, permitting imaging of beam sensitive materials to be obtained without changing the microscope operating parameters. The use of sparse line-hopping scan to acquire STEM images is demonstrated with atomic resolution aberration corrected Z-contrast images of CaCO3, a material that is traditionally difficult to image by TEM/STEM because of dose issues.

  10. A Rapid and Accurate Solution for the Poisson Equation with Neumann Boundary Conditions on General Domains.

    Science.gov (United States)

    1981-12-17

    4] Hockney , R. W., "The Potential Calculation and Some Application," Methods in Computational Physics, Vol. 9, 1970, pp. 135-211. [5] Ghia, K. N. and...Merkle Commander The Pennsylvania State University David W. Taylor Naval Ship R&D Center Department of Mechanical Engineering Department of the Navy

  11. High Order Accurate Algorithms for Shocks, Rapidly Changing Solutions and Multiscale Problems

    Science.gov (United States)

    2014-11-13

    convection boundary layer flow and heat transfer of non - Newtonian power law fluid over a cylinder. Different from most classical works, the temperature...dependent variable fluid viscosity and thermal conductivity are taken into account in highly coupled velocity and temperature fields. The motion of the...SECURITY CLASSIFICATION OF: Research has been performed on weighted essentially non -oscillatory schemes and discontinuous Galerkin methods, and other

  12. Rapid, accurate and direct determination of total lycopene content in tomato paste

    NARCIS (Netherlands)

    Bicanic, D.D.; Anese, M.; Luterotti, S.; Dadarlat, D.; Gibkes, J.; Lubbers, M.T.M.H.

    2003-01-01

    Lycopene that imparts red color to the tomato fruit is the most potent antioxidant among carotenes, an important nutrient and also used as a color ingredient in many food formulations. Since cooked and processed foods derived from tomatoes were shown to provide optimal lycopene boost, products such

  13. TRI Preliminary Dataset

    Science.gov (United States)

    The TRI preliminary dataset includes the most current TRI data available and reflects toxic chemical releases and pollution prevention activities that occurred at TRI facilities during the each calendar year.

  14. 2016 TRI Preliminary Dataset

    Science.gov (United States)

    The TRI preliminary dataset includes the most current TRI data available and reflects toxic chemical releases and pollution prevention activities that occurred at TRI facilities during the 2016 calendar year.

  15. Corrosion of metal samples rapidly measured

    Science.gov (United States)

    Maskell, C. E.

    1966-01-01

    Corrosion of a large number of metal samples that have been exposed to controlled environment is accurately and rapidly measured. Wire samples of the metal are embedded in clear plastic and sectioned for microexamination. Unexposed wire can be included in the matrix as a reference.

  16. Fast and accurate methods for phylogenomic analyses

    Directory of Open Access Journals (Sweden)

    Warnow Tandy

    2011-10-01

    Full Text Available Abstract Background Species phylogenies are not estimated directly, but rather through phylogenetic analyses of different gene datasets. However, true gene trees can differ from the true species tree (and hence from one another due to biological processes such as horizontal gene transfer, incomplete lineage sorting, and gene duplication and loss, so that no single gene tree is a reliable estimate of the species tree. Several methods have been developed to estimate species trees from estimated gene trees, differing according to the specific algorithmic technique used and the biological model used to explain differences between species and gene trees. Relatively little is known about the relative performance of these methods. Results We report on a study evaluating several different methods for estimating species trees from sequence datasets, simulating sequence evolution under a complex model including indels (insertions and deletions, substitutions, and incomplete lineage sorting. The most important finding of our study is that some fast and simple methods are nearly as accurate as the most accurate methods, which employ sophisticated statistical methods and are computationally quite intensive. We also observe that methods that explicitly consider errors in the estimated gene trees produce more accurate trees than methods that assume the estimated gene trees are correct. Conclusions Our study shows that highly accurate estimations of species trees are achievable, even when gene trees differ from each other and from the species tree, and that these estimations can be obtained using fairly simple and computationally tractable methods.

  17. Accurate overlaying for mobile augmented reality

    NARCIS (Netherlands)

    Pasman, W; van der Schaaf, A; Lagendijk, RL; Jansen, F.W.

    1999-01-01

    Mobile augmented reality requires accurate alignment of virtual information with objects visible in the real world. We describe a system for mobile communications to be developed to meet these strict alignment criteria using a combination of computer vision. inertial tracking and low-latency

  18. Accurate automatic profile monitoring. Genaue automatische Profilkontrolle

    Energy Technology Data Exchange (ETDEWEB)

    Sacher, F. (Amberg Messtechnik AG (Germany))

    1994-06-09

    It is almost inconceivable that the present tunnelling methods will not employ modern surveying and monitoring technologies. Accurate, automatic profile monitoring is an aid to optimization of construction work in technical, financial and scheduling respects. These aspects are explained in more detail on the basis of a description of use, various practical examples and a cost analysis. (orig.)

  19. Leveraging Two Kinect Sensors for Accurate Full-Body Motion Capture.

    Science.gov (United States)

    Gao, Zhiquan; Yu, Yao; Zhou, Yu; Du, Sidan

    2015-09-22

    Accurate motion capture plays an important role in sports analysis, the medical field and virtual reality. Current methods for motion capture often suffer from occlusions, which limits the accuracy of their pose estimation. In this paper, we propose a complete system to measure the pose parameters of the human body accurately. Different from previous monocular depth camera systems, we leverage two Kinect sensors to acquire more information about human movements, which ensures that we can still get an accurate estimation even when significant occlusion occurs. Because human motion is temporally constant, we adopt a learning analysis to mine the temporal information across the posture variations. Using this information, we estimate human pose parameters accurately, regardless of rapid movement. Our experimental results show that our system can perform an accurate pose estimation of the human body with the constraint of information from the temporal domain.

  20. Rapid Diagnosis of Bacterial Meningitis Using a Microarray

    Directory of Open Access Journals (Sweden)

    Ren-Jy Ben

    2008-06-01

    Conclusion: The microarray method provides a more accurate and rapid diagnostic tool for bacterial meningitis compared to traditional culture methods. Clinical application of this new technique may reduce the potential risk of delay in treatment.

  1. Feedback about More Accurate versus Less Accurate Trials: Differential Effects on Self-Confidence and Activation

    Science.gov (United States)

    Badami, Rokhsareh; VaezMousavi, Mohammad; Wulf, Gabriele; Namazizadeh, Mahdi

    2012-01-01

    One purpose of the present study was to examine whether self-confidence or anxiety would be differentially affected by feedback from more accurate rather than less accurate trials. The second purpose was to determine whether arousal variations (activation) would predict performance. On Day 1, participants performed a golf putting task under one of…

  2. New Claus catalyst tests accurately reflect process conditions

    Energy Technology Data Exchange (ETDEWEB)

    Maglio, A.; Schubert, P.F.

    1988-09-12

    Methods for testing Claus catalysts are developed that more accurately represent the actual operating conditions in commercial sulfur recovery units. For measuring catalyst activity, an aging method has been developed that results in more meaningful activity data after the catalyst has been aged, because all catalysts undergo rapid initial deactivation in commercial units. An activity test method has been developed where catalysts can be compared at less than equilibrium conversion. A test has also been developed to characterize abrasion loss of Claus catalysts, in contrast to the traditional method of determining physical properties by measuring crush strengths. Test results from a wide range of materials correlated well with actual pneumatic conveyance attrition. Substantial differences in Claus catalyst properties were observed as a result of using these tests.

  3. An Integrative Approach to Accurate Vehicle Logo Detection

    Directory of Open Access Journals (Sweden)

    Hao Pan

    2013-01-01

    required for many applications in intelligent transportation systems and automatic surveillance. The task is challenging considering the small target of logos and the wide range of variability in shape, color, and illumination. A fast and reliable vehicle logo detection approach is proposed following visual attention mechanism from the human vision. Two prelogo detection steps, that is, vehicle region detection and a small RoI segmentation, rapidly focalize a small logo target. An enhanced Adaboost algorithm, together with two types of features of Haar and HOG, is proposed to detect vehicles. An RoI that covers logos is segmented based on our prior knowledge about the logos’ position relative to license plates, which can be accurately localized from frontal vehicle images. A two-stage cascade classier proceeds with the segmented RoI, using a hybrid of Gentle Adaboost and Support Vector Machine (SVM, resulting in precise logo positioning. Extensive experiments were conducted to verify the efficiency of the proposed scheme.

  4. Accurate estimation of indoor travel times

    DEFF Research Database (Denmark)

    Prentow, Thor Siiger; Blunck, Henrik; Stisen, Allan

    2014-01-01

    The ability to accurately estimate indoor travel times is crucial for enabling improvements within application areas such as indoor navigation, logistics for mobile workers, and facility management. In this paper, we study the challenges inherent in indoor travel time estimation, and we propose...... the InTraTime method for accurately estimating indoor travel times via mining of historical and real-time indoor position traces. The method learns during operation both travel routes, travel times and their respective likelihood---both for routes traveled as well as for sub-routes thereof. InTraTime...... allows to specify temporal and other query parameters, such as time-of-day, day-of-week or the identity of the traveling individual. As input the method is designed to take generic position traces and is thus interoperable with a variety of indoor positioning systems. The method's advantages include...

  5. Highly Accurate Prediction of Jobs Runtime Classes

    OpenAIRE

    Anat Reiner-Benaim; Anna Grabarnick; Edi Shmueli

    2016-01-01

    Separating the short jobs from the long is a known technique to improve scheduling performance. In this paper we describe a method we developed for accurately predicting the runtimes classes of the jobs to enable this separation. Our method uses the fact that the runtimes can be represented as a mixture of overlapping Gaussian distributions, in order to train a CART classifier to provide the prediction. The threshold that separates the short jobs from the long jobs is determined during the ev...

  6. Accurate Calculation of Electric Fields Inside Enzymes.

    Science.gov (United States)

    Wang, X; He, X; Zhang, J Z H

    2016-01-01

    The specific electric field generated by a protease at its active site is considered as an important source of the catalytic power. Accurate calculation of electric field at the active site of an enzyme has both fundamental and practical importance. Measuring site-specific changes of electric field at internal sites of proteins due to, eg, mutation, has been realized by using molecular probes with CO or CN groups in the context of vibrational Stark effect. However, theoretical prediction of change in electric field inside a protein based on a conventional force field, such as AMBER or OPLS, is often inadequate. For such calculation, quantum chemical approach or quantum-based polarizable or polarized force field is highly preferable. Compared with the result from conventional force field, significant improvement is found in predicting experimentally measured mutation-induced electric field change using quantum-based methods, indicating that quantum effect such as polarization plays an important role in accurate description of electric field inside proteins. In comparison, the best theoretical prediction comes from fully quantum mechanical calculation in which both polarization and inter-residue charge transfer effects are included for accurate prediction of electrostatics in proteins. © 2016 Elsevier Inc. All rights reserved.

  7. ACCURATE CHEMICAL MASTER EQUATION SOLUTION USING MULTI-FINITE BUFFERS

    Science.gov (United States)

    Cao, Youfang; Terebus, Anna; Liang, Jie

    2016-01-01

    The discrete chemical master equation (dCME) provides a fundamental framework for studying stochasticity in mesoscopic networks. Because of the multi-scale nature of many networks where reaction rates have large disparity, directly solving dCMEs is intractable due to the exploding size of the state space. It is important to truncate the state space effectively with quantified errors, so accurate solutions can be computed. It is also important to know if all major probabilistic peaks have been computed. Here we introduce the Accurate CME (ACME) algorithm for obtaining direct solutions to dCMEs. With multi-finite buffers for reducing the state space by O(n!), exact steady-state and time-evolving network probability landscapes can be computed. We further describe a theoretical framework of aggregating microstates into a smaller number of macrostates by decomposing a network into independent aggregated birth and death processes, and give an a priori method for rapidly determining steady-state truncation errors. The maximal sizes of the finite buffers for a given error tolerance can also be pre-computed without costly trial solutions of dCMEs. We show exactly computed probability landscapes of three multi-scale networks, namely, a 6-node toggle switch, 11-node phage-lambda epigenetic circuit, and 16-node MAPK cascade network, the latter two with no known solutions. We also show how probabilities of rare events can be computed from first-passage times, another class of unsolved problems challenging for simulation-based techniques due to large separations in time scales. Overall, the ACME method enables accurate and efficient solutions of the dCME for a large class of networks. PMID:27761104

  8. Accurate reading with sequential presentation of single letters

    Directory of Open Access Journals (Sweden)

    Nicholas Seow Chiang Price

    2012-10-01

    Full Text Available Rapid, accurate reading is possible when isolated, single words from a sentence are sequentially presented at a fixed spatial location. We investigated if reading of words and sentences is possible when single letters are rapidly presented at the fovea under user-controlled or automatically-controlled rates. When tested with complete sentences, trained participants achieved reading rates of over 60 words/minute and accuracies of over 90% with the single letter reading (SLR method and naive participants achieved average reading rates over 30 wpm with >90% accuracy. Accuracy declined as individual letters were presented for shorter periods of time, even when the overall reading rate was maintained by increasing the duration of spaces between words. Words in the lexicon that occur more frequently were identified with higher accuracy and more quickly, demonstrating that trained participants have lexical access. In combination, our data strongly suggest that comprehension is possible and that SLR is a practicable form of reading under conditions in which normal scanning of text is not possible, or for scenarios with limited spatial and temporal resolution such as patients with low vision or prostheses.

  9. Rapid diagnosis of mycobacterial infections

    Directory of Open Access Journals (Sweden)

    Michel Drancourt

    2015-01-01

    Full Text Available While pulmonary tuberculosis (PTB remains an important public health issue worldwide, there is an emerging interest in non-tuberculous mycobacteria (NTM which is responsible for opportunistic infections of the respiratory tract as well as other anatomical sites in both developed and developing countries. In this context the one goal of the clinical mycobacteriology laboratories is to provide physicians with an accurate identification of the mycobacterium as rapidly as possible. During the last ten years, several lines of laboratory tools have been developed in order to speed the isolation and identification of mycobacteria from clinical specimens. Chiefly, the composition of culture medium was renewed along with the protocol of incubation in order to recover Mycobacterium tuberculosis (MTB micro-colonies as soon as 48 h after the inoculation of the specimen. MALDI-TOF rapid identification is clearly the tool to be implemented in the laboratory for the rapid identification of the micro-colonies. Also, molecular tools and genomics are necessary in order to depict new mycobacteria species, including those of the Mycobacterium abscessus complex and the Mycobacterium avium complex. All these tools and their connections will be presented during this conference.

  10. Methodology for Computer-aided, Interactive Rapid Assessment of Local or Regional Stress Fields on Mars

    Science.gov (United States)

    Colton, S. L.; Ferrill, D. A.; Sims, D. W.; Wyrick, D. Y.; Franklin, N. M.

    2003-03-01

    We present a method for rapid assessment of stress fields on Mars: (i) mapping geologic structures, (ii) calculating stress fields, and (iii) determining resolved stresses on faults. Preliminary results are presented for northern Utopia Planitia.

  11. Accurate measurement of unsteady state fluid temperature

    Science.gov (United States)

    Jaremkiewicz, Magdalena

    2017-03-01

    In this paper, two accurate methods for determining the transient fluid temperature were presented. Measurements were conducted for boiling water since its temperature is known. At the beginning the thermometers are at the ambient temperature and next they are immediately immersed into saturated water. The measurements were carried out with two thermometers of different construction but with the same housing outer diameter equal to 15 mm. One of them is a K-type industrial thermometer widely available commercially. The temperature indicated by the thermometer was corrected considering the thermometers as the first or second order inertia devices. The new design of a thermometer was proposed and also used to measure the temperature of boiling water. Its characteristic feature is a cylinder-shaped housing with the sheath thermocouple located in its center. The temperature of the fluid was determined based on measurements taken in the axis of the solid cylindrical element (housing) using the inverse space marching method. Measurements of the transient temperature of the air flowing through the wind tunnel using the same thermometers were also carried out. The proposed measurement technique provides more accurate results compared with measurements using industrial thermometers in conjunction with simple temperature correction using the inertial thermometer model of the first or second order. By comparing the results, it was demonstrated that the new thermometer allows obtaining the fluid temperature much faster and with higher accuracy in comparison to the industrial thermometer. Accurate measurements of the fast changing fluid temperature are possible due to the low inertia thermometer and fast space marching method applied for solving the inverse heat conduction problem.

  12. Climate Models have Accurately Predicted Global Warming

    Science.gov (United States)

    Nuccitelli, D. A.

    2016-12-01

    Climate model projections of global temperature changes over the past five decades have proven remarkably accurate, and yet the myth that climate models are inaccurate or unreliable has formed the basis of many arguments denying anthropogenic global warming and the risks it poses to the climate system. Here we compare average global temperature predictions made by both mainstream climate scientists using climate models, and by contrarians using less physically-based methods. We also explore the basis of the myth by examining specific arguments against climate model accuracy and their common characteristics of science denial.

  13. A preliminary assessment of the potential risks from electrical ...

    African Journals Online (AJOL)

    concern in Kenya, 17 (71 %) face a high risk of direct interactions with electrical infrastructure. Priority species ... A rapid preliminary risk assessment of electrical infrastructure was conducted in two areas of Kenya: i) ..... The fundamentals and practice of Overhead Line Maintenance (132kV and above), pp217-245. Eskom ...

  14. ROUTES: a computer program for preliminary route location.

    Science.gov (United States)

    S.E. Reutebuch

    1988-01-01

    An analytical description of the ROUTES computer program is presented. ROUTES is part of the integrated preliminary harvest- and transportation-planning software package, PLANS. The ROUTES computer program is useful where grade and sideslope limitations are important in determining routes for vehicular travel. With the program, planners can rapidly identify route...

  15. Accurate renormalization group analyses in neutrino sector

    Energy Technology Data Exchange (ETDEWEB)

    Haba, Naoyuki [Graduate School of Science and Engineering, Shimane University, Matsue 690-8504 (Japan); Kaneta, Kunio [Kavli IPMU (WPI), The University of Tokyo, Kashiwa, Chiba 277-8568 (Japan); Takahashi, Ryo [Graduate School of Science and Engineering, Shimane University, Matsue 690-8504 (Japan); Yamaguchi, Yuya [Department of Physics, Faculty of Science, Hokkaido University, Sapporo 060-0810 (Japan)

    2014-08-15

    We investigate accurate renormalization group analyses in neutrino sector between ν-oscillation and seesaw energy scales. We consider decoupling effects of top quark and Higgs boson on the renormalization group equations of light neutrino mass matrix. Since the decoupling effects are given in the standard model scale and independent of high energy physics, our method can basically apply to any models beyond the standard model. We find that the decoupling effects of Higgs boson are negligible, while those of top quark are not. Particularly, the decoupling effects of top quark affect neutrino mass eigenvalues, which are important for analyzing predictions such as mass squared differences and neutrinoless double beta decay in an underlying theory existing at high energy scale.

  16. Accurate metacognition for visual sensory memory representations.

    Science.gov (United States)

    Vandenbroucke, Annelinde R E; Sligte, Ilja G; Barrett, Adam B; Seth, Anil K; Fahrenfort, Johannes J; Lamme, Victor A F

    2014-04-01

    The capacity to attend to multiple objects in the visual field is limited. However, introspectively, people feel that they see the whole visual world at once. Some scholars suggest that this introspective feeling is based on short-lived sensory memory representations, whereas others argue that the feeling of seeing more than can be attended to is illusory. Here, we investigated this phenomenon by combining objective memory performance with subjective confidence ratings during a change-detection task. This allowed us to compute a measure of metacognition--the degree of knowledge that subjects have about the correctness of their decisions--for different stages of memory. We show that subjects store more objects in sensory memory than they can attend to but, at the same time, have similar metacognition for sensory memory and working memory representations. This suggests that these subjective impressions are not an illusion but accurate reflections of the richness of visual perception.

  17. Accurate predictions for the LHC made easy

    CERN Multimedia

    CERN. Geneva

    2014-01-01

    The data recorded by the LHC experiments is of a very high quality. To get the most out of the data, precise theory predictions, including uncertainty estimates, are needed to reduce as much as possible theoretical bias in the experimental analyses. Recently, significant progress has been made in computing Next-to-Leading Order (NLO) computations, including matching to the parton shower, that allow for these accurate, hadron-level predictions. I shall discuss one of these efforts, the MadGraph5_aMC@NLO program, that aims at the complete automation of predictions at the NLO accuracy within the SM as well as New Physics theories. I’ll illustrate some of the theoretical ideas behind this program, show some selected applications to LHC physics, as well as describe the future plans.

  18. Fast and accurate multicomponent transport property evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Ern, A. [CERMICS-ENPC, Le Grand (France)]|[Yale Univ., New Haven, CT (United States); Giovangigli, V. [CMAP-CNRS, Palaiseau (France)

    1995-08-01

    We investigate iterative methods for solving linear systems arising from the kinetic theory and providing transport coefficients of dilute polyatomic gas mixtures. These linear systems are obtained in their naturally constrained, singular, and symmetric form, using the formalism of Waldmann and Truebenbacher. The transport coefficients associated with the systems obtained by Monchick, Yun, and Mason are also recovered, if two misprints are corrected in the work of these authors. Using the recent theory of Ern and Giovangigli, all the transport coefficients are expressed as convergent series. By truncating these series, new, accurate, approximate expressions are obtained for all the transport coefficients. Finally, the computational efficiency of the present transport algorithms in multicomponent flow applications is illustrated with several numerical experiments. 38 refs., 12 tabs.

  19. Apparatus for accurately measuring high temperatures

    Science.gov (United States)

    Smith, D.D.

    The present invention is a thermometer used for measuring furnace temperatures in the range of about 1800/sup 0/ to 2700/sup 0/C. The thermometer comprises a broadband multicolor thermal radiation sensor positioned to be in optical alignment with the end of a blackbody sight tube extending into the furnace. A valve-shutter arrangement is positioned between the radiation sensor and the sight tube and a chamber for containing a charge of high pressure gas is positioned between the valve-shutter arrangement and the radiation sensor. A momentary opening of the valve shutter arrangement allows a pulse of the high gas to purge the sight tube of air-borne thermal radiation contaminants which permits the radiation sensor to accurately measure the thermal radiation emanating from the end of the sight tube.

  20. Surface integral formulation of Maxwell's equations for simulation of non-destructive testing by eddy currents. Preliminary study on the implementation of the fast multipole method; Formulation integrale surfacique des equations de Maxwell pour la simulation de controles non destructifs par courant de Foucault. Etude preliminaire a la mise en oeuvre de la methode multipole rapide.

    Energy Technology Data Exchange (ETDEWEB)

    Lim, T.

    2011-04-28

    To simulate numerically a non-destructive by eddy current testing (NDT-CF), the sensor response can be modeled through a semi-analytical approach by volume integral equations. Faster than the finite element method, this approach is however restricted to the study of plane or cylindrical parts (without taking into account the edge effects) because of the complexity of the expression of the dyadic Green function for more general configurations. However, there is an industrial demand to extend the capabilities of the CF model in complex configurations (deformed plates, edges effects...). We were thus brought to formulate the electromagnetic problem differently, by setting ourselves the goal of maintaining a semi-analytical approach. The surface integral equation (SIE) expresses the volume problem by an equivalent transmission one at the interfaces (2D) between homogeneous sub-domains. This problem is approached by a linear system (by the method of moments), whose number of unknowns is reduced due to the nature of the surfacic mesh. Therefore, this system can be solved by a direct solver for small configurations. That enabled us to treat several various positions of the sensor for only one inversion of the impedance matrix. The numerical results obtained using this formulation involve plates with consideration of edge effects such as edge and corner. They are consistent with results obtained by the finite element method. For larger configurations, we conducted a preliminary study for the adaptation of an acceleration method of the matrix vector product involved in an iterative solver (fast multipole method or FMM) to define the conditions under which the FMM calculation works correctly (accuracy, convergence...) in the NDT's domain. A special attention has been given to the choice of basis functions (which have to satisfy an Hdiv conforming property) and on the evaluation of near interactions (which are weakly singular). (author) [French] Pour simuler

  1. New accurate measurements of neutron emission probabilities for relevant fission products

    Directory of Open Access Journals (Sweden)

    Agramunt J.

    2017-01-01

    Full Text Available We have performed new accurate measurements of the beta-delayed neutron emission probability for ten isotopes of the elements Y, Sb, Te and I. These are fission products that either have a significant contribution to the fraction of delayed neutrons in reactors or are relatively close to the path of the astrophysical r process. The measurements were performed with isotopically pure radioactive beams using a constant and high efficiency neutron counter and a low noise beta detector. Preliminary results are presented for six of the isotopes and compared with previous measurements and theoretical calculations.

  2. Accurate atom-mapping computation for biochemical reactions.

    Science.gov (United States)

    Latendresse, Mario; Malerich, Jeremiah P; Travers, Mike; Karp, Peter D

    2012-11-26

    The complete atom mapping of a chemical reaction is a bijection of the reactant atoms to the product atoms that specifies the terminus of each reactant atom. Atom mapping of biochemical reactions is useful for many applications of systems biology, in particular for metabolic engineering where synthesizing new biochemical pathways has to take into account for the number of carbon atoms from a source compound that are conserved in the synthesis of a target compound. Rapid, accurate computation of the atom mapping(s) of a biochemical reaction remains elusive despite significant work on this topic. In particular, past researchers did not validate the accuracy of mapping algorithms. We introduce a new method for computing atom mappings called the minimum weighted edit-distance (MWED) metric. The metric is based on bond propensity to react and computes biochemically valid atom mappings for a large percentage of biochemical reactions. MWED models can be formulated efficiently as Mixed-Integer Linear Programs (MILPs). We have demonstrated this approach on 7501 reactions of the MetaCyc database for which 87% of the models could be solved in less than 10 s. For 2.1% of the reactions, we found multiple optimal atom mappings. We show that the error rate is 0.9% (22 reactions) by comparing these atom mappings to 2446 atom mappings of the manually curated Kyoto Encyclopedia of Genes and Genomes (KEGG) RPAIR database. To our knowledge, our computational atom-mapping approach is the most accurate and among the fastest published to date. The atom-mapping data will be available in the MetaCyc database later in 2012; the atom-mapping software will be available within the Pathway Tools software later in 2012.

  3. Accurate, fully-automated NMR spectral profiling for metabolomics.

    Science.gov (United States)

    Ravanbakhsh, Siamak; Liu, Philip; Bjorndahl, Trent C; Bjordahl, Trent C; Mandal, Rupasri; Grant, Jason R; Wilson, Michael; Eisner, Roman; Sinelnikov, Igor; Hu, Xiaoyu; Luchinat, Claudio; Greiner, Russell; Wishart, David S

    2015-01-01

    Many diseases cause significant changes to the concentrations of small molecules (a.k.a. metabolites) that appear in a person's biofluids, which means such diseases can often be readily detected from a person's "metabolic profile"-i.e., the list of concentrations of those metabolites. This information can be extracted from a biofluids Nuclear Magnetic Resonance (NMR) spectrum. However, due to its complexity, NMR spectral profiling has remained manual, resulting in slow, expensive and error-prone procedures that have hindered clinical and industrial adoption of metabolomics via NMR. This paper presents a system, BAYESIL, which can quickly, accurately, and autonomously produce a person's metabolic profile. Given a 1D 1H NMR spectrum of a complex biofluid (specifically serum or cerebrospinal fluid), BAYESIL can automatically determine the metabolic profile. This requires first performing several spectral processing steps, then matching the resulting spectrum against a reference compound library, which contains the "signatures" of each relevant metabolite. BAYESIL views spectral matching as an inference problem within a probabilistic graphical model that rapidly approximates the most probable metabolic profile. Our extensive studies on a diverse set of complex mixtures including real biological samples (serum and CSF), defined mixtures and realistic computer generated spectra; involving > 50 compounds, show that BAYESIL can autonomously find the concentration of NMR-detectable metabolites accurately (~ 90% correct identification and ~ 10% quantification error), in less than 5 minutes on a single CPU. These results demonstrate that BAYESIL is the first fully-automatic publicly-accessible system that provides quantitative NMR spectral profiling effectively-with an accuracy on these biofluids that meets or exceeds the performance of trained experts. We anticipate this tool will usher in high-throughput metabolomics and enable a wealth of new applications of NMR in

  4. Accurate, fully-automated NMR spectral profiling for metabolomics.

    Directory of Open Access Journals (Sweden)

    Siamak Ravanbakhsh

    Full Text Available Many diseases cause significant changes to the concentrations of small molecules (a.k.a. metabolites that appear in a person's biofluids, which means such diseases can often be readily detected from a person's "metabolic profile"-i.e., the list of concentrations of those metabolites. This information can be extracted from a biofluids Nuclear Magnetic Resonance (NMR spectrum. However, due to its complexity, NMR spectral profiling has remained manual, resulting in slow, expensive and error-prone procedures that have hindered clinical and industrial adoption of metabolomics via NMR. This paper presents a system, BAYESIL, which can quickly, accurately, and autonomously produce a person's metabolic profile. Given a 1D 1H NMR spectrum of a complex biofluid (specifically serum or cerebrospinal fluid, BAYESIL can automatically determine the metabolic profile. This requires first performing several spectral processing steps, then matching the resulting spectrum against a reference compound library, which contains the "signatures" of each relevant metabolite. BAYESIL views spectral matching as an inference problem within a probabilistic graphical model that rapidly approximates the most probable metabolic profile. Our extensive studies on a diverse set of complex mixtures including real biological samples (serum and CSF, defined mixtures and realistic computer generated spectra; involving > 50 compounds, show that BAYESIL can autonomously find the concentration of NMR-detectable metabolites accurately (~ 90% correct identification and ~ 10% quantification error, in less than 5 minutes on a single CPU. These results demonstrate that BAYESIL is the first fully-automatic publicly-accessible system that provides quantitative NMR spectral profiling effectively-with an accuracy on these biofluids that meets or exceeds the performance of trained experts. We anticipate this tool will usher in high-throughput metabolomics and enable a wealth of new applications of

  5. Rapid Prototyping Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The ARDEC Rapid Prototyping (RP) Laboratory was established in December 1992 to provide low cost RP capabilities to the ARDEC engineering community. The Stratasys,...

  6. UVISS preliminary visibility analysis

    DEFF Research Database (Denmark)

    Betto, Maurizio

    1998-01-01

    The goal of this work is to obtain a preliminary assessment of the sky visibility for anastronomical telescope located on the express pallet of the International SpaceStation (ISS)} taking into account the major constraints imposed on the instrument by the ISSattitude and structure. Part of the w......The goal of this work is to obtain a preliminary assessment of the sky visibility for anastronomical telescope located on the express pallet of the International SpaceStation (ISS)} taking into account the major constraints imposed on the instrument by the ISSattitude and structure. Part...... of the work is also to setup the kernel of a software tool for the visibility analysis thatshould be easily expandable to consider more complex strucures for future activities.This analysis is part of the UVISS assessment study and it is meant to provide elementsfor the definition and the selection...

  7. Rapid detection of listeria spp. using an internalin A aptasensor based on carbon-metal nanohybrid structures

    Science.gov (United States)

    Vanegas, D. C.; Rong, Yue; Schwalb, N.; Hills, K. D.; Gomes, C.; McLamore, E. S.

    2015-05-01

    Foodborne outbreaks caused by Listeria monocytogenes continue to raise major public health concerns worldwide. In the United States alone, the centers for disease control and prevention have confirmed the occurrence of 183 cases of listeriosis with 39 fatalities within the last 3 years. Standard methods for the detection of pathogenic strains require up to 7 days to yield results, thus faster techniques with the same level of reliability for bacteria detection are desirable. This study reports on the development of a rapid, accurate, and sensitive electrochemical biosensor for rapid testing of Listeria spp. based on the selective binding of InlA aptamers to internalins in the cell membrane of the target bacteria. Hybrid nanomaterial platforms based on reduced graphene oxide and nanoplatinum were deposited onto Pt/Ir electrodes for enhancing electrochemical transduction during the recognition events. InlA aptamers were immobilized onto the nanomaterial platforms via metal-thiol adsorption. Aptamer loading onto different platform nanostructures was investigated through cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The detection mechanism was evaluated by recording the electrochemical response to several bacterial dilutions in PBS buffer using the non-pathogenic species Listeria innocua. These preliminary results show that the aptasensor can be tuned for detection of Listeria concentrations as low as 100 CFU/ml in less than 3 hours (including incubation time and data analysis). The developed aptasensor opens a promising direction for rapid testing of Listeria monocytogenes in food products.

  8. Use of GMM and SCMS for Accurate Road Centerline Extraction from the Classified Image

    Directory of Open Access Journals (Sweden)

    Zelang Miao

    2015-01-01

    Full Text Available The extraction of road centerline from the classified image is a fundamental image analysis technology. Common problems encountered in road centerline extraction include low ability for coping with the general case, production of undesired objects, and inefficiency. To tackle these limitations, this paper presents a novel accurate centerline extraction method using Gaussian mixture model (GMM and subspace constraint mean shift (SCMS. The proposed method consists of three main steps. GMM is first used to partition the classified image into several clusters. The major axis of the ellipsoid of each cluster is extracted and deemed to be taken as the initial centerline. Finally, the initial result is adjusted using SCMS to produce precise road centerline. Both simulated and real datasets are used to validate the proposed method. Preliminary results demonstrate that the proposed method provides a comparatively robust solution for accurate centerline extraction from a classified image.

  9. Preliminary decommissioning study reports

    Energy Technology Data Exchange (ETDEWEB)

    Reed, W.R.

    1984-09-01

    The Old Hydrofracture Facility (OHF) is one of approximately 76 facilities currently managed by the Oak Ridge National Laboratory (ORNL) Surplus Facilities Management Program (SFMP). This program, as part of the Department of Energy (DOE) national SFMP, is responsible for the maintenance and surveillance and the final decommissioning of radioactively contaminated surplus ORNL facilities. A long-range planning effort is being conducted that will outline the scope and objectives of the ORNL program and establish decommissioning priorities based on health and safety concerns, budget constraints, and other progammatic constraints. IN support of this SFMP planning activity, preliminary engineering assessments are being conducted for each of the ORNL surplus facilities currently managed under the program. These efforts are designed to: (1) provide an initial assessment of the potential decommissioning alternatives, (2) choose a preferred alternative and provide a justification for that choice, and (3) provide a preliminary description of the decommissioning plan, including cost and schedule estimates. This report presents the results of the preliminary analysis for the OHF.

  10. A stiffly accurate integrator for elastodynamic problems

    KAUST Repository

    Michels, Dominik L.

    2017-07-21

    We present a new integration algorithm for the accurate and efficient solution of stiff elastodynamic problems governed by the second-order ordinary differential equations of structural mechanics. Current methods have the shortcoming that their performance is highly dependent on the numerical stiffness of the underlying system that often leads to unrealistic behavior or a significant loss of efficiency. To overcome these limitations, we present a new integration method which is based on a mathematical reformulation of the underlying differential equations, an exponential treatment of the full nonlinear forcing operator as opposed to more standard partially implicit or exponential approaches, and the utilization of the concept of stiff accuracy which ensures that the efficiency of the simulations is significantly less sensitive to increased stiffness. As a consequence, we are able to tremendously accelerate the simulation of stiff systems compared to established integrators and significantly increase the overall accuracy. The advantageous behavior of this approach is demonstrated on a broad spectrum of complex examples like deformable bodies, textiles, bristles, and human hair. Our easily parallelizable integrator enables more complex and realistic models to be explored in visual computing without compromising efficiency.

  11. Accurate Theoretical Thermochemistry for Fluoroethyl Radicals.

    Science.gov (United States)

    Ganyecz, Ádám; Kállay, Mihály; Csontos, József

    2017-02-09

    An accurate coupled-cluster (CC) based model chemistry was applied to calculate reliable thermochemical quantities for hydrofluorocarbon derivatives including radicals 1-fluoroethyl (CH3-CHF), 1,1-difluoroethyl (CH3-CF2), 2-fluoroethyl (CH2F-CH2), 1,2-difluoroethyl (CH2F-CHF), 2,2-difluoroethyl (CHF2-CH2), 2,2,2-trifluoroethyl (CF3-CH2), 1,2,2,2-tetrafluoroethyl (CF3-CHF), and pentafluoroethyl (CF3-CF2). The model chemistry used contains iterative triple and perturbative quadruple excitations in CC theory, as well as scalar relativistic and diagonal Born-Oppenheimer corrections. To obtain heat of formation values with better than chemical accuracy perturbative quadruple excitations and scalar relativistic corrections were inevitable. Their contributions to the heats of formation steadily increase with the number of fluorine atoms in the radical reaching 10 kJ/mol for CF3-CF2. When discrepancies were found between the experimental and our values it was always possible to resolve the issue by recalculating the experimental result with currently recommended auxiliary data. For each radical studied here this study delivers the best heat of formation as well as entropy data.

  12. Accurate lineshape spectroscopy and the Boltzmann constant.

    Science.gov (United States)

    Truong, G-W; Anstie, J D; May, E F; Stace, T M; Luiten, A N

    2015-10-14

    Spectroscopy has an illustrious history delivering serendipitous discoveries and providing a stringent testbed for new physical predictions, including applications from trace materials detection, to understanding the atmospheres of stars and planets, and even constraining cosmological models. Reaching fundamental-noise limits permits optimal extraction of spectroscopic information from an absorption measurement. Here, we demonstrate a quantum-limited spectrometer that delivers high-precision measurements of the absorption lineshape. These measurements yield a very accurate measurement of the excited-state (6P1/2) hyperfine splitting in Cs, and reveals a breakdown in the well-known Voigt spectral profile. We develop a theoretical model that accounts for this breakdown, explaining the observations to within the shot-noise limit. Our model enables us to infer the thermal velocity dispersion of the Cs vapour with an uncertainty of 35 p.p.m. within an hour. This allows us to determine a value for Boltzmann's constant with a precision of 6 p.p.m., and an uncertainty of 71 p.p.m.

  13. Accurate Emission Line Diagnostics at High Redshift

    Science.gov (United States)

    Jones, Tucker

    2017-08-01

    How do the physical conditions of high redshift galaxies differ from those seen locally? Spectroscopic surveys have invested hundreds of nights of 8- and 10-meter telescope time as well as hundreds of Hubble orbits to study evolution in the galaxy population at redshifts z 0.5-4 using rest-frame optical strong emission line diagnostics. These surveys reveal evolution in the gas excitation with redshift but the physical cause is not yet understood. Consequently there are large systematic errors in derived quantities such as metallicity.We have used direct measurements of gas density, temperature, and metallicity in a unique sample at z=0.8 to determine reliable diagnostics for high redshift galaxies. Our measurements suggest that offsets in emission line ratios at high redshift are primarily caused by high N/O abundance ratios. However, our ground-based data cannot rule out other interpretations. Spatially resolved Hubble grism spectra are needed to distinguish between the remaining plausible causes such as active nuclei, shocks, diffuse ionized gas emission, and HII regions with escaping ionizing flux. Identifying the physical origin of evolving excitation will allow us to build the necessary foundation for accurate measurements of metallicity and other properties of high redshift galaxies. Only then can we expoit the wealth of data from current surveys and near-future JWST spectroscopy to understand how galaxies evolve over time.

  14. Fast and accurate exhaled breath ammonia measurement.

    Science.gov (United States)

    Solga, Steven F; Mudalel, Matthew L; Spacek, Lisa A; Risby, Terence H

    2014-06-11

    This exhaled breath ammonia method uses a fast and highly sensitive spectroscopic method known as quartz enhanced photoacoustic spectroscopy (QEPAS) that uses a quantum cascade based laser. The monitor is coupled to a sampler that measures mouth pressure and carbon dioxide. The system is temperature controlled and specifically designed to address the reactivity of this compound. The sampler provides immediate feedback to the subject and the technician on the quality of the breath effort. Together with the quick response time of the monitor, this system is capable of accurately measuring exhaled breath ammonia representative of deep lung systemic levels. Because the system is easy to use and produces real time results, it has enabled experiments to identify factors that influence measurements. For example, mouth rinse and oral pH reproducibly and significantly affect results and therefore must be controlled. Temperature and mode of breathing are other examples. As our understanding of these factors evolves, error is reduced, and clinical studies become more meaningful. This system is very reliable and individual measurements are inexpensive. The sampler is relatively inexpensive and quite portable, but the monitor is neither. This limits options for some clinical studies and provides rational for future innovations.

  15. Comparative Ebulliometry: a Simple, Reliable Technique for Accurate Measurement of the Number Average Molecular Weight of Macromolecules. Preliminary Studies on Heavy Crude Fractions Ébulliométrie comparative : technique simple et fiable pour déterminer précisément la masse molaire moyenne en nombre des macromolécules. Etudes préliminaires sur des fractions lourdes de bruts

    Directory of Open Access Journals (Sweden)

    Behar E.

    2006-12-01

    Full Text Available This article is divided into two parts. In the first part, the authors present a comparison of the major techniques for the measurement of the molecular weight of macromolecules. The bibliographic results are gathered in several tables. In the second part, a comparative ebulliometer for the measurement of the number average molecular weight (Mn of heavy crude oil fractions is described. The high efficiency of the apparatus is demonstrated with a preliminary study of atmospheric distillation residues and resins. The measurement of molecular weights up to 2000 g/mol is possible in less than 4 hours with an uncertainty of about 2%. Cet article comprend deux parties. Dans la première, les auteurs présentent une comparaison entre les principales techniques de détermination de la masse molaire de macromolécules. Les résultats de l'étude bibliographique sont rassemblés dans plusieurs tableaux. La seconde partie décrit un ébulliomètre comparatif conçu pour la mesure de la masse molaire moyenne en nombre (Mn des fractions lourdes des bruts. Une illustration de l'efficacité de cet appareil est indiquée avec l'étude préliminaire de résidus de distillation atmosphérique et de résines. En particulier, la mesure de masses molaires pouvant atteindre 2000 g/mol est possible en moins de 4 heures avec une incertitude expérimentale de l'ordre de 2 %.

  16. Towards Accurate Application Characterization for Exascale (APEX)

    Energy Technology Data Exchange (ETDEWEB)

    Hammond, Simon David [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)

    2015-09-01

    Sandia National Laboratories has been engaged in hardware and software codesign activities for a number of years, indeed, it might be argued that prototyping of clusters as far back as the CPLANT machines and many large capability resources including ASCI Red and RedStorm were examples of codesigned solutions. As the research supporting our codesign activities has moved closer to investigating on-node runtime behavior a nature hunger has grown for detailed analysis of both hardware and algorithm performance from the perspective of low-level operations. The Application Characterization for Exascale (APEX) LDRD was a project concieved of addressing some of these concerns. Primarily the research was to intended to focus on generating accurate and reproducible low-level performance metrics using tools that could scale to production-class code bases. Along side this research was an advocacy and analysis role associated with evaluating tools for production use, working with leading industry vendors to develop and refine solutions required by our code teams and to directly engage with production code developers to form a context for the application analysis and a bridge to the research community within Sandia. On each of these accounts significant progress has been made, particularly, as this report will cover, in the low-level analysis of operations for important classes of algorithms. This report summarizes the development of a collection of tools under the APEX research program and leaves to other SAND and L2 milestone reports the description of codesign progress with Sandia’s production users/developers.

  17. Accurate Thermal Conductivities from First Principles

    Science.gov (United States)

    Carbogno, Christian

    2015-03-01

    In spite of significant research efforts, a first-principles determination of the thermal conductivity at high temperatures has remained elusive. On the one hand, Boltzmann transport techniques that include anharmonic effects in the nuclear dynamics only perturbatively become inaccurate or inapplicable under such conditions. On the other hand, non-equilibrium molecular dynamics (MD) methods suffer from enormous finite-size artifacts in the computationally feasible supercells, which prevent an accurate extrapolation to the bulk limit of the thermal conductivity. In this work, we overcome this limitation by performing ab initio MD simulations in thermodynamic equilibrium that account for all orders of anharmonicity. The thermal conductivity is then assessed from the auto-correlation function of the heat flux using the Green-Kubo formalism. Foremost, we discuss the fundamental theory underlying a first-principles definition of the heat flux using the virial theorem. We validate our approach and in particular the techniques developed to overcome finite time and size effects, e.g., by inspecting silicon, the thermal conductivity of which is particularly challenging to converge. Furthermore, we use this framework to investigate the thermal conductivity of ZrO2, which is known for its high degree of anharmonicity. Our calculations shed light on the heat resistance mechanism active in this material, which eventually allows us to discuss how the thermal conductivity can be controlled by doping and co-doping. This work has been performed in collaboration with R. Ramprasad (University of Connecticut), C. G. Levi and C. G. Van de Walle (University of California Santa Barbara).

  18. Optimizing cell arrays for accurate functional genomics.

    Science.gov (United States)

    Fengler, Sven; Bastiaens, Philippe I H; Grecco, Hernán E; Roda-Navarro, Pedro

    2012-07-17

    Cellular responses emerge from a complex network of dynamic biochemical reactions. In order to investigate them is necessary to develop methods that allow perturbing a high number of gene products in a flexible and fast way. Cell arrays (CA) enable such experiments on microscope slides via reverse transfection of cellular colonies growing on spotted genetic material. In contrast to multi-well plates, CA are susceptible to contamination among neighboring spots hindering accurate quantification in cell-based screening projects. Here we have developed a quality control protocol for quantifying and minimizing contamination in CA. We imaged checkered CA that express two distinct fluorescent proteins and segmented images into single cells to quantify the transfection efficiency and interspot contamination. Compared with standard procedures, we measured a 3-fold reduction of contaminants when arrays containing HeLa cells were washed shortly after cell seeding. We proved that nucleic acid uptake during cell seeding rather than migration among neighboring spots was the major source of contamination. Arrays of MCF7 cells developed without the washing step showed 7-fold lower percentage of contaminant cells, demonstrating that contamination is dependent on specific cell properties. Previously published methodological works have focused on achieving high transfection rate in densely packed CA. Here, we focused in an equally important parameter: The interspot contamination. The presented quality control is essential for estimating the rate of contamination, a major source of false positives and negatives in current microscopy based functional genomics screenings. We have demonstrated that a washing step after seeding enhances CA quality for HeLA but is not necessary for MCF7. The described method provides a way to find optimal seeding protocols for cell lines intended to be used for the first time in CA.

  19. Optimizing cell arrays for accurate functional genomics

    Directory of Open Access Journals (Sweden)

    Fengler Sven

    2012-07-01

    Full Text Available Abstract Background Cellular responses emerge from a complex network of dynamic biochemical reactions. In order to investigate them is necessary to develop methods that allow perturbing a high number of gene products in a flexible and fast way. Cell arrays (CA enable such experiments on microscope slides via reverse transfection of cellular colonies growing on spotted genetic material. In contrast to multi-well plates, CA are susceptible to contamination among neighboring spots hindering accurate quantification in cell-based screening projects. Here we have developed a quality control protocol for quantifying and minimizing contamination in CA. Results We imaged checkered CA that express two distinct fluorescent proteins and segmented images into single cells to quantify the transfection efficiency and interspot contamination. Compared with standard procedures, we measured a 3-fold reduction of contaminants when arrays containing HeLa cells were washed shortly after cell seeding. We proved that nucleic acid uptake during cell seeding rather than migration among neighboring spots was the major source of contamination. Arrays of MCF7 cells developed without the washing step showed 7-fold lower percentage of contaminant cells, demonstrating that contamination is dependent on specific cell properties. Conclusions Previously published methodological works have focused on achieving high transfection rate in densely packed CA. Here, we focused in an equally important parameter: The interspot contamination. The presented quality control is essential for estimating the rate of contamination, a major source of false positives and negatives in current microscopy based functional genomics screenings. We have demonstrated that a washing step after seeding enhances CA quality for HeLA but is not necessary for MCF7. The described method provides a way to find optimal seeding protocols for cell lines intended to be used for the first time in CA.

  20. How flatbed scanners upset accurate film dosimetry.

    Science.gov (United States)

    van Battum, L J; Huizenga, H; Verdaasdonk, R M; Heukelom, S

    2016-01-21

    Film is an excellent dosimeter for verification of dose distributions due to its high spatial resolution. Irradiated film can be digitized with low-cost, transmission, flatbed scanners. However, a disadvantage is their lateral scan effect (LSE): a scanner readout change over its lateral scan axis. Although anisotropic light scattering was presented as the origin of the LSE, this paper presents an alternative cause. Hereto, LSE for two flatbed scanners (Epson 1680 Expression Pro and Epson 10000XL), and Gafchromic film (EBT, EBT2, EBT3) was investigated, focused on three effects: cross talk, optical path length and polarization. Cross talk was examined using triangular sheets of various optical densities. The optical path length effect was studied using absorptive and reflective neutral density filters with well-defined optical characteristics (OD range 0.2-2.0). Linear polarizer sheets were used to investigate light polarization on the CCD signal in absence and presence of (un)irradiated Gafchromic film. Film dose values ranged between 0.2 to 9 Gy, i.e. an optical density range between 0.25 to 1.1. Measurements were performed in the scanner's transmission mode, with red-green-blue channels. LSE was found to depend on scanner construction and film type. Its magnitude depends on dose: for 9 Gy increasing up to 14% at maximum lateral position. Cross talk was only significant in high contrast regions, up to 2% for very small fields. The optical path length effect introduced by film on the scanner causes 3% for pixels in the extreme lateral position. Light polarization due to film and the scanner's optical mirror system is the main contributor, different in magnitude for the red, green and blue channel. We concluded that any Gafchromic EBT type film scanned with a flatbed scanner will face these optical effects. Accurate dosimetry requires correction of LSE, therefore, determination of the LSE per color channel and dose delivered to the film.

  1. Important Nearby Galaxies without Accurate Distances

    Science.gov (United States)

    McQuinn, Kristen

    2014-10-01

    The Spitzer Infrared Nearby Galaxies Survey (SINGS) and its offspring programs (e.g., THINGS, HERACLES, KINGFISH) have resulted in a fundamental change in our view of star formation and the ISM in galaxies, and together they represent the most complete multi-wavelength data set yet assembled for a large sample of nearby galaxies. These great investments of observing time have been dedicated to the goal of understanding the interstellar medium, the star formation process, and, more generally, galactic evolution at the present epoch. Nearby galaxies provide the basis for which we interpret the distant universe, and the SINGS sample represents the best studied nearby galaxies.Accurate distances are fundamental to interpreting observations of galaxies. Surprisingly, many of the SINGS spiral galaxies have numerous distance estimates resulting in confusion. We can rectify this situation for 8 of the SINGS spiral galaxies within 10 Mpc at a very low cost through measurements of the tip of the red giant branch. The proposed observations will provide an accuracy of better than 0.1 in distance modulus. Our sample includes such well known galaxies as M51 (the Whirlpool), M63 (the Sunflower), M104 (the Sombrero), and M74 (the archetypal grand design spiral).We are also proposing coordinated parallel WFC3 UV observations of the central regions of the galaxies, rich with high-mass UV-bright stars. As a secondary science goal we will compare the resolved UV stellar populations with integrated UV emission measurements used in calibrating star formation rates. Our observations will complement the growing HST UV atlas of high resolution images of nearby galaxies.

  2. Concurrent and Accurate Short Read Mapping on Multicore Processors.

    Science.gov (United States)

    Martínez, Héctor; Tárraga, Joaquín; Medina, Ignacio; Barrachina, Sergio; Castillo, Maribel; Dopazo, Joaquín; Quintana-Ortí, Enrique S

    2015-01-01

    We introduce a parallel aligner with a work-flow organization for fast and accurate mapping of RNA sequences on servers equipped with multicore processors. Our software, HPG Aligner SA (HPG Aligner SA is an open-source application. The software is available at http://www.opencb.org, exploits a suffix array to rapidly map a large fraction of the RNA fragments (reads), as well as leverages the accuracy of the Smith-Waterman algorithm to deal with conflictive reads. The aligner is enhanced with a careful strategy to detect splice junctions based on an adaptive division of RNA reads into small segments (or seeds), which are then mapped onto a number of candidate alignment locations, providing crucial information for the successful alignment of the complete reads. The experimental results on a platform with Intel multicore technology report the parallel performance of HPG Aligner SA, on RNA reads of 100-400 nucleotides, which excels in execution time/sensitivity to state-of-the-art aligners such as TopHat 2+Bowtie 2, MapSplice, and STAR.

  3. Accuracy of rapid disposition by emergency clinicians.

    Science.gov (United States)

    Backay, Andrew; Bystrzycki, Adam; Smit, De Villiers; Keogh, Martin; O'Reilly, Gerard; Mitra, Biswadev

    2017-05-01

    Objectives Rapid disposition protocols are increasingly being considered for implementation in emergency departments (EDs). Among patients presenting to an adult tertiary referral hospital, this study aimed to compare prediction accuracy of a rapid disposition decision at the conclusion of history and examination, compared with disposition following standard assessment. Methods Prospective observational data were collected for 1 month between October and November 2012. Emergency clinicians (including physicians, registrars, hospital medical officers, interns and nurse practitioners) filled out a questionnaire within 5min of obtaining a history and clinical examination for eligible patients. Predicted patient disposition (representing 'rapid disposition') was compared with final disposition (determined by 'standard assessment'). Results There were 301 patient episodes included in the study. Predicted disposition was correct in 249 (82.7%, 95% confidence interval (CI) 78.0-86.8) cases. Accuracy of predicting discharge to home appeared highest among emergency physicians at 95.8% (95% CI 78.9-99.9). Overall accuracy at predicting admission was 79.7% (95% CI 67.2-89.0). The remaining 20.3% (95% CI 11.0-32.8) were not admitted following standard assessment. Conclusion Rapid disposition by ED clinicians can predict patient destination accurately but was associated with a potential increase in admission rates. Any model of care using rapid disposition decision making should involve establishment of inpatient systems for further assessment, and a culture of timely inpatient team transfer of patients to the most appropriate treating team for ongoing patient management. What is known about the topic? In response to the National Emergency Access Targets, there has been widespread adoption of rapid-disposition-themed care models across Australia. Although there is emerging data that clinicians can predict disposition accurately, this data is currently limited. What does this

  4. Polyjet technology applications for rapid tooling

    Directory of Open Access Journals (Sweden)

    Udroiu Razvan

    2017-01-01

    Full Text Available Polymer Jetting (PolyJet has proved to be one of the most accurate additive manufacturing technologies, in order to manufacture rapid tools. Rapid Tooling (RT is different from conventional tooling as follow: manufacturing time is shorter, the cost is much less, but the tool life is shorter and tolerances are wider. The purpose of this paper is to make a comparative study between the soft tools (silicon moulds and hard tools (acrylic thermoplastic moulds based on the Polymer Jetting technology. Thus, two types of moulds have been made in order to manufacture a test part. Reaction injection moulding (RIM and casting techniques were used to fill these moulds with resins that simulate the plastic injection materials. Rapid tooling applications, such as indirect tooling and direct tooling, based on PolyJet technology were experimentally investigated.

  5. An Efficient Approach for Fast and Accurate Voltage Stability Margin Computation in Large Power Grids

    OpenAIRE

    Heng-Yi Su

    2016-01-01

    This paper proposes an efficient approach for the computation of voltage stability margin (VSM) in a large-scale power grid. The objective is to accurately and rapidly determine the load power margin which corresponds to voltage collapse phenomena. The proposed approach is based on the impedance match-based technique and the model-based technique. It combines the Thevenin equivalent (TE) network method with cubic spline extrapolation technique and the continuation technique to achieve fast an...

  6. Diagnostic Limitations to Accurate Diagnosis of Cholera▿

    Science.gov (United States)

    Alam, Munirul; Hasan, Nur A.; Sultana, Marzia; Nair, G. Balakrish; Sadique, A.; Faruque, A. S. G.; Endtz, Hubert P.; Sack, R. B.; Huq, A.; Colwell, R. R.; Izumiya, Hidemasa; Morita, Masatomo; Watanabe, Haruo; Cravioto, Alejandro

    2010-01-01

    The treatment regimen for diarrhea depends greatly on correct diagnosis of its etiology. Recent diarrhea outbreaks in Bangladesh showed Vibrio cholerae to be the predominant cause, although more than 40% of the suspected cases failed to show cholera etiology by conventional culture methods (CMs). In the present study, suspected cholera stools collected from every 50th patient during an acute diarrheal outbreak were analyzed extensively using different microbiological and molecular tools to determine their etiology. Of 135 stools tested, 86 (64%) produced V. cholerae O1 by CMs, while 119 (88%) tested positive for V. cholerae O1 by rapid cholera dipstick (DS) assay; all but three samples positive for V. cholerae O1 by CMs were also positive for V. cholerae O1 by DS assay. Of 49 stools that lacked CM-based cholera etiology despite most being positive for V. cholerae O1 by DS assay, 25 (51%) had coccoid V. cholerae O1 cells as confirmed by direct fluorescent antibody (DFA) assay, 36 (73%) amplified primers for the genes wbe O1 and ctxA by multiplex-PCR (M-PCR), and 31 (63%) showed El Tor-specific lytic phage on plaque assay (PA). Each of these methods allowed the cholera etiology to be confirmed for 97% of the stool samples. The results suggest that suspected cholera stools that fail to show etiology by CMs during acute diarrhea outbreaks may be due to the inactivation of V. cholerae by in vivo vibriolytic action of the phage and/or nonculturability induced as a host response. PMID:20739485

  7. Are patients referred to rehabilitation diagnosed accurately?

    Science.gov (United States)

    Tederko, Piotr; Krasuski, Marek; Nyka, Izabella; Mycielski, Jerzy; Tarnacka, Beata

    2017-07-17

    An accurate diagnosis of the leading health condition and comorbidities is a prerequisite for safe and effective rehabilitation. The problem of diagnostic errors in physical and rehabilitation medicine (PRM) has not been addressed sufficiently. The responsibility of a referring physician is to determine indications and contraindications for rehabilitation. To assess the rate of and risk factors for inaccurate referral diagnoses (RD) in patients referred to a rehabilitation facility. We hypothesized that inaccurate RD would be more common in patients 1) referred by non-PRM physicians; 2) waiting longer for the admission; 3) older patients. Retrospective observational study. 1000 randomly selected patients admitted between 2012 and 2016 to a day- rehabilitation center (DRC). University DRC specialized in musculoskeletal diseases. On admission all cases underwent clinical verification of RD. Inappropriateness regarding primary diagnoses and comorbidities were noted. Influence of several factors affecting probability of inaccurate RD was analyzed with multiple binary regression model applied to 6 categories of diseases. The rate of inaccurate RD was 25.2%. Higher frequency of inaccurate RD was noted among patients referred by non-PRM specialists (30.3% vs 17.3% in cases referred by PRM specialists). Application of logit regression showed highly significant influence of the specialty of a referring physician on the odds of inaccurate RD (joint Wald test ch2(6)=38.98, p- value=0.000), controlling for the influence of other variables. This may reflect a suboptimal knowledge of the rehabilitation process and a tendency to neglect of comorbidities by non-PRM specialists. The rate of inaccurate RD did not correlate with time between referral and admission (joint Wald test of all odds ratios equal to 1, chi2(6)=5.62, p-value=0.467), however, mean and median waiting times were relatively short (35.7 and 25 days respectively).A high risk of overlooked multimorbidity was

  8. An automated method for accurate vessel segmentation

    Science.gov (United States)

    Yang, Xin; Liu, Chaoyue; Le Minh, Hung; Wang, Zhiwei; Chien, Aichi; (Tim Cheng, Kwang-Ting

    2017-05-01

    Vessel segmentation is a critical task for various medical applications, such as diagnosis assistance of diabetic retinopathy, quantification of cerebral aneurysm’s growth, and guiding surgery in neurosurgical procedures. Despite technology advances in image segmentation, existing methods still suffer from low accuracy for vessel segmentation in the two challenging while common scenarios in clinical usage: (1) regions with a low signal-to-noise-ratio (SNR), and (2) at vessel boundaries disturbed by adjacent non-vessel pixels. In this paper, we present an automated system which can achieve highly accurate vessel segmentation for both 2D and 3D images even under these challenging scenarios. Three key contributions achieved by our system are: (1) a progressive contrast enhancement method to adaptively enhance contrast of challenging pixels that were otherwise indistinguishable, (2) a boundary refinement method to effectively improve segmentation accuracy at vessel borders based on Canny edge detection, and (3) a content-aware region-of-interests (ROI) adjustment method to automatically determine the locations and sizes of ROIs which contain ambiguous pixels and demand further verification. Extensive evaluation of our method is conducted on both 2D and 3D datasets. On a public 2D retinal dataset (named DRIVE (Staal 2004 IEEE Trans. Med. Imaging 23 501-9)) and our 2D clinical cerebral dataset, our approach achieves superior performance to the state-of-the-art methods including a vesselness based method (Frangi 1998 Int. Conf. on Medical Image Computing and Computer-Assisted Intervention) and an optimally oriented flux (OOF) based method (Law and Chung 2008 European Conf. on Computer Vision). An evaluation on 11 clinical 3D CTA cerebral datasets shows that our method can achieve 94% average accuracy with respect to the manual segmentation reference, which is 23% to 33% better than the five baseline methods (Yushkevich 2006 Neuroimage 31 1116-28; Law and Chung 2008

  9. Environmental Survey preliminary report

    Energy Technology Data Exchange (ETDEWEB)

    1988-04-01

    This report presents the preliminary findings from the first phase of the Environmental Survey of the United States Department of Energy (DOE) Sandia National Laboratories conducted August 17 through September 4, 1987. The objective of the Survey is to identify environmental problems and areas of environmental risk associated with Sandia National Laboratories-Albuquerque (SNLA). The Survey covers all environmental media and all areas of environmental regulation. It is being performed in accordance with the DOE Environmental Survey Manual. This phase of the Survey involves the review of existing site environmental data, observations of the operations carried on at SNLA, and interviews with site personnel. 85 refs., 49 figs., 48 tabs.

  10. Rapid shallow breathing

    Science.gov (United States)

    ... the smallest air passages of the lungs in children ( bronchiolitis ) Pneumonia or other lung infection Transient tachypnea of the newborn Anxiety and panic Other serious lung disease Home Care Rapid, shallow breathing should not be treated at home. It is ...

  11. Rapid Strep Test

    Science.gov (United States)

    ... worse than normal. Your first thoughts turn to strep throat. A rapid strep test in your doctor’s office ... your suspicions.Viruses cause most sore throats. However, strep throat is an infection caused by the Group A ...

  12. RAPID3? Aptly named!

    Science.gov (United States)

    Berthelot, J-M

    2014-01-01

    The RAPID3 score is the sum of three 0-10 patient self-report scores: pain, functional impairment on MDHAQ, and patient global estimate. It requires 5 seconds for scoring and can be used in all rheumatologic conditions, although it has mostly been used in rheumatoid arthritis where cutoffs for low disease activity (12/30) have been set. A RAPID3 score of ≤ 3/30 with 1 or 0 swollen joints (RAPID3 ≤ 3 + ≤ SJ1) provides remission criteria comparable to Boolean, SDAI, CDAI, and DAS28 remission criteria, in far less time than a formal joint count. RAPID3 performs as well as the DAS28 in separating active drugs from placebos in clinical trials. RAPID3 also predicts subsequent structural disease progression. RAPID3 can be determined at short intervals at home, allowing the determination of the area under the curve of disease activity between two visits and flare detection. However, RAPID3 should not be seen as a substitute for DAS28 and face to face visits in routine care. Monitoring patient status with only self-report information without a rheumatologist's advice (including joints and physical examination, and consideration of imaging and laboratory tests) may indeed be as undesirable for most patients than joint examination without a patient questionnaire. Conversely, combining the RAPID3 and the DAS28 may consist in faster or more sensitive confirmation that a medication is effective. Similarly, better enquiring of most important concerns of patients (pain, functional status and overall opinion on their disorder) should reinforces patients' confidence in their rheumatologist and treatments.

  13. Accurate mobile malware detection and classification in the cloud.

    Science.gov (United States)

    Wang, Xiaolei; Yang, Yuexiang; Zeng, Yingzhi

    2015-01-01

    As the dominator of the Smartphone operating system market, consequently android has attracted the attention of s malware authors and researcher alike. The number of types of android malware is increasing rapidly regardless of the considerable number of proposed malware analysis systems. In this paper, by taking advantages of low false-positive rate of misuse detection and the ability of anomaly detection to detect zero-day malware, we propose a novel hybrid detection system based on a new open-source framework CuckooDroid, which enables the use of Cuckoo Sandbox's features to analyze Android malware through dynamic and static analysis. Our proposed system mainly consists of two parts: anomaly detection engine performing abnormal apps detection through dynamic analysis; signature detection engine performing known malware detection and classification with the combination of static and dynamic analysis. We evaluate our system using 5560 malware samples and 6000 benign samples. Experiments show that our anomaly detection engine with dynamic analysis is capable of detecting zero-day malware with a low false negative rate (1.16 %) and acceptable false positive rate (1.30 %); it is worth noting that our signature detection engine with hybrid analysis can accurately classify malware samples with an average positive rate 98.94 %. Considering the intensive computing resources required by the static and dynamic analysis, our proposed detection system should be deployed off-device, such as in the Cloud. The app store markets and the ordinary users can access our detection system for malware detection through cloud service.

  14. Rapid small lot manufacturing

    Energy Technology Data Exchange (ETDEWEB)

    Harrigan, R.W.

    1998-05-09

    The direct connection of information, captured in forms such as CAD databases, to the factory floor is enabling a revolution in manufacturing. Rapid response to very dynamic market conditions is becoming the norm rather than the exception. In order to provide economical rapid fabrication of small numbers of variable products, one must design with manufacturing constraints in mind. In addition, flexible manufacturing systems must be programmed automatically to reduce the time for product change over in the factory and eliminate human errors. Sensor based machine control is needed to adapt idealized, model based machine programs to uncontrolled variables such as the condition of raw materials and fabrication tolerances.

  15. Rapid Cycling and Its Treatment

    Science.gov (United States)

    ... Announcements Public Service Announcements Partnering with DBSA Rapid Cycling and its Treatment What is bipolar disorder? Bipolar ... to Depression and Manic Depression . What is rapid cycling? Rapid cycling is defined as four or more ...

  16. Using optical coherence tomography to rapidly phenotype and quantify congenital heart defects associated with prenatal alcohol exposure.

    Science.gov (United States)

    Karunamuni, Ganga; Gu, Shi; Doughman, Yong Qiu; Noonan, Amanda I; Rollins, Andrew M; Jenkins, Michael W; Watanabe, Michiko

    2015-04-01

    The most commonly used method to analyze congenital heart defects involves serial sectioning and histology. However, this is often a time-consuming process where the quantification of cardiac defects can be difficult due to problems with accurate section registration. Here we demonstrate the advantages of using optical coherence tomography, a comparatively new and rising technology, to phenotype avian embryo hearts in a model of fetal alcohol syndrome where a binge-like quantity of alcohol/ethanol was introduced at gastrulation. The rapid, consistent imaging protocols allowed for the immediate identification of cardiac anomalies, including ventricular septal defects and misaligned/missing vessels. Interventricular septum thicknesses and vessel diameters for three of the five outflow arteries were also significantly reduced. Outflow and atrioventricular valves were segmented using image processing software and had significantly reduced volumes compared to controls. This is the first study to our knowledge that has 3D reconstructed the late-stage cardiac valves in precise detail to examine their morphology and dimensions. We believe, therefore, that optical coherence tomography, with its ability to rapidly image and quantify tiny embryonic structures in high resolution, will serve as an excellent and cost-effective preliminary screening tool for developmental biologists working with a variety of experimental/disease models. © 2014 Wiley Periodicals, Inc.

  17. Rapid manufacturing for microfluidics

    CSIR Research Space (South Africa)

    Land, K

    2012-10-01

    Full Text Available . Microfluidics is at the forefront of developing solutions for drug discovery, diagnostics (from glucose tests to malaria and TB testing) and environmental diagnostics (E-coli monitoring of drinking water). In order to quickly implement new designs, a rapid...

  18. Rapid Prototyping in PVS

    Science.gov (United States)

    Munoz, Cesar A.; Butler, Ricky (Technical Monitor)

    2003-01-01

    PVSio is a conservative extension to the PVS prelude library that provides basic input/output capabilities to the PVS ground evaluator. It supports rapid prototyping in PVS by enhancing the specification language with built-in constructs for string manipulation, floating point arithmetic, and input/output operations.

  19. Rapid Prototyping Reconsidered

    Science.gov (United States)

    Desrosier, James

    2011-01-01

    Continuing educators need additional strategies for developing new programming that can both reduce the time to market and lower the cost of development. Rapid prototyping, a time-compression technique adapted from the high technology industry, represents one such strategy that merits renewed evaluation. Although in higher education rapid…

  20. Jet-Like Correlations between Forward and Mid-Rapidity

    CERN Document Server

    Wang, F

    2007-01-01

    Mid-rapidity azimuthal correlations probe di-jets originating mainly from gluon-gluon hard-scattering. Measurements of such correlations have revealed significant (gluon-)jet modification in central Au+Au collisions. Azimuthal correlations at forward rapidity with a mid-rapidity high-pt hadron, on the other hand, are sensitive primarily to quark-gluon hard-scattering and may probe quark-jet modification in nuclear medium. They may be also sensitive to the Color Glass Condensate by separating d-side and Au-side in d+Au collisions. We present the first results on correlations of charged hadrons at forward rapidity in the STAR FTPCs (2.7 3 GeV/c). Preliminary results from pp, d+Au, and Au+Au collisions at 200 GeV are compared. Implications of the results are discussed.

  1. Rapid solidification via melt spinning - Equipment and techniques

    Science.gov (United States)

    Jech, R. W.; Moore, T. J.; Glasgow, T. K.; Orth, N. W.

    1984-01-01

    One of the simpler methods available to accomplish rapid solidification processing is free jet melt spinning. With only a modest expenditure of time, effort, and capital, an apparatus suitable for preliminary experimentation can be assembled. Wheel and crucible materials, process atmospheres, crucible design, heating methods, and process parameters and their relationship to melt composition are described. Practical solutions to processing problems, based on 'hands-on' experience, are offered. Alloys with melting points up to 3000 F have been rapidly solidified using the techniques described.

  2. Host markers in Quantiferon supernatants differentiate active TB from latent TB infection: preliminary report

    Directory of Open Access Journals (Sweden)

    Walzl Gerhard

    2009-05-01

    Full Text Available Abstract Background Interferon gamma release assays, including the QuantiFERON® TB Gold In Tube (QFT have been shown to be accurate in diagnosing Mycobacterium tuberculosis infection. These assays however, do not discriminate between latent TB infection (LTBI and active TB disease. Methods We recruited twenty-three pulmonary TB patients and 34 household contacts from Cape Town, South Africa and performed the QFT test. To investigate the ability of new host markers to differentiate between LTBI and active TB, levels of 29 biomarkers in QFT supernatants were evaluated using a Luminex multiplex cytokine assay. Results Eight out of 29 biomarkers distinguished active TB from LTBI in a pilot study. Baseline levels of epidermal growth factor (EGF soluble CD40 ligand (sCD40L, antigen stimulated levels of EGF, and the background corrected antigen stimulated levels of EGF and macrophage inflammatory protein (MIP-1β were the most informative single markers for differentiation between TB disease and LTBI, with AUCs of 0.88, 0.84, 0.87, 0.90 and 0.79 respectively. The combination of EGF and MIP-1β predicted 96% of active TB cases and 92% of LTBIs. Combinations between EGF, sCD40L, VEGF, TGF-α and IL-1α also showed potential to differentiate between TB infection states. EGF, VEGF, TGF-α and sCD40L levels were higher in TB patients. Conclusion These preliminary data suggest that active TB may be accurately differentiated from LTBI utilizing adaptations of the commercial QFT test that includes measurement of EGF, sCD40L, MIP-1β, VEGF, TGF-α or IL-1α in supernatants from QFT assays. This approach holds promise for development as a rapid diagnostic test for active TB.

  3. Biomimetic Approach for Accurate, Real-Time Aerodynamic Coefficients Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Aerodynamic and structural reliability and efficiency depends critically on the ability to accurately assess the aerodynamic loads and moments for each lifting...

  4. A PRELIMINARY JUPITER MODEL

    Energy Technology Data Exchange (ETDEWEB)

    Hubbard, W. B. [Lunar and Planetary Laboratory, The University of Arizona, Tucson, AZ 85721 (United States); Militzer, B. [Department of Earth and Planetary Science, Department of Astronomy, University of California, Berkeley, CA 94720 (United States)

    2016-03-20

    In anticipation of new observational results for Jupiter's axial moment of inertia and gravitational zonal harmonic coefficients from the forthcoming Juno orbiter, we present a number of preliminary Jupiter interior models. We combine results from ab initio computer simulations of hydrogen–helium mixtures, including immiscibility calculations, with a new nonperturbative calculation of Jupiter's zonal harmonic coefficients, to derive a self-consistent model for the planet's external gravity and moment of inertia. We assume helium rain modified the interior temperature and composition profiles. Our calculation predicts zonal harmonic values to which measurements can be compared. Although some models fit the observed (pre-Juno) second- and fourth-order zonal harmonics to within their error bars, our preferred reference model predicts a fourth-order zonal harmonic whose absolute value lies above the pre-Juno error bars. This model has a dense core of about 12 Earth masses and a hydrogen–helium-rich envelope with approximately three times solar metallicity.

  5. Rapid Prototyping of Electrically Small Spherical Wire Antennas

    DEFF Research Database (Denmark)

    Kim, Oleksiy S.

    2014-01-01

    It is shown how modern rapid prototyping technologies can be applied for quick and inexpensive, but still accurate, fabrication of electrically small wire antennas. A well known folded spherical helix antenna and a novel spherical zigzag antenna have been fabricated and tested, exhibiting the imp...

  6. Two Unusual Occurrences of Trichomoniasis: Rapid Species Identification by PCR▿

    Science.gov (United States)

    Bellanger, A. P.; Cabaret, O.; Costa, J. M.; Foulet, F.; Bretagne, S.; Botterel, F.

    2008-01-01

    PCR analysis in two unusual occurrences of trichomoniasis, trichomonal empyema due to Trichomonas tenax and Trichomonas vaginalis in an infant urine sample, allowed us to obtain rapid and accurate trichomonad species identification. The weak sensitivity of wet preparations and the low viability of the flagellates can be remedied by the PCR method. PMID:18632901

  7. Development of rapid phenotypic system for the identification of ...

    Indian Academy of Sciences (India)

    Rapid and accurate identification of bacterial pathogens is a fundamental goal of clinical microbiology. The diagnosis and surveillance of diseases is dependent, to a great extent, on laboratory services, which cannot function without effective reliable reagents and diagnostics. Despite the advancement in microbiology ...

  8. Rapid manufacturing facilitated customisation

    OpenAIRE

    Tuck, Christopher John; Hague, Richard; Ruffo, Massimiliano; Ransley, Michelle; Adams, Paul Russell

    2008-01-01

    Abstract This paper describes the production of body-fitting customised seat profiles utilising the following digital methods: three dimensional laser scanning, reverse engineering and Rapid Manufacturing (RM). The seat profiles have been manufactured in order to influence the comfort characteristics of an existing ejector seat manufactured by Martin Baker Aircraft Ltd. The seat, known as Navy Aircrew Common Ejection Seat (NACES), was originally designed with a generic profile. ...

  9. Estimating the Effective Permittivity for Reconstructing Accurate Microwave-Radar Images.

    Science.gov (United States)

    Lavoie, Benjamin R; Okoniewski, Michal; Fear, Elise C

    2016-01-01

    We present preliminary results from a method for estimating the optimal effective permittivity for reconstructing microwave-radar images. Using knowledge of how microwave-radar images are formed, we identify characteristics that are typical of good images, and define a fitness function to measure the relative image quality. We build a polynomial interpolant of the fitness function in order to identify the most likely permittivity values of the tissue. To make the estimation process more efficient, the polynomial interpolant is constructed using a locally and dimensionally adaptive sampling method that is a novel combination of stochastic collocation and polynomial chaos. Examples, using a series of simulated, experimental and patient data collected using the Tissue Sensing Adaptive Radar system, which is under development at the University of Calgary, are presented. These examples show how, using our method, accurate images can be reconstructed starting with only a broad estimate of the permittivity range.

  10. Estimating the Effective Permittivity for Reconstructing Accurate Microwave-Radar Images.

    Directory of Open Access Journals (Sweden)

    Benjamin R Lavoie

    Full Text Available We present preliminary results from a method for estimating the optimal effective permittivity for reconstructing microwave-radar images. Using knowledge of how microwave-radar images are formed, we identify characteristics that are typical of good images, and define a fitness function to measure the relative image quality. We build a polynomial interpolant of the fitness function in order to identify the most likely permittivity values of the tissue. To make the estimation process more efficient, the polynomial interpolant is constructed using a locally and dimensionally adaptive sampling method that is a novel combination of stochastic collocation and polynomial chaos. Examples, using a series of simulated, experimental and patient data collected using the Tissue Sensing Adaptive Radar system, which is under development at the University of Calgary, are presented. These examples show how, using our method, accurate images can be reconstructed starting with only a broad estimate of the permittivity range.

  11. Automated rapid finite fault inversion for megathrust earthquakes: Application to the Maule (2010), Iquique (2014) and Illapel (2015) great earthquakes

    Science.gov (United States)

    Benavente, Roberto; Cummins, Phil; Dettmer, Jan

    2016-04-01

    Rapid estimation of the spatial and temporal rupture characteristics of large megathrust earthquakes by finite fault inversion is important for disaster mitigation. For example, estimates of the spatio-temporal evolution of rupture can be used to evaluate population exposure to tsunami waves and ground shaking soon after the event by providing more accurate predictions than possible with point source approximations. In addition, rapid inversion results can reveal seismic source complexity to guide additional, more detailed subsequent studies. This work develops a method to rapidly estimate the slip distribution of megathrust events while reducing subjective parameter choices by automation. The method is simple yet robust and we show that it provides excellent preliminary rupture models as soon as 30 minutes for three great earthquakes in the South-American subduction zone. This may slightly change for other regions depending on seismic station coverage but method can be applied to any subduction region. The inversion is based on W-phase data since it is rapidly and widely available and of low amplitude which avoids clipping at close stations for large events. In addition, prior knowledge of the slab geometry (e.g. SLAB 1.0) is applied and rapid W-phase point source information (time delay and centroid location) is used to constrain the fault geometry and extent. Since the linearization by multiple time window (MTW) parametrization requires regularization, objective smoothing is achieved by the discrepancy principle in two fully automated steps. First, the residuals are estimated assuming unknown noise levels, and second, seeking a subsequent solution which fits the data to noise level. The MTW scheme is applied with positivity constraints and a solution is obtained by an efficient non-negative least squares solver. Systematic application of the algorithm to the Maule (2010), Iquique (2014) and Illapel (2015) events illustrates that rapid finite fault inversion with

  12. Tiber Personal Rapid Transit

    Directory of Open Access Journals (Sweden)

    Diego Carlo D'agostino

    2011-02-01

    Full Text Available The project “Tiber Personal Rapid Transit” have been presented by the author at the Rome City Vision Competition1 2010, an ideas competition, which challenges architects, engineers, designers, students and creatives individuals to develop visionary urban proposals with the intention of stimulating and supporting the contemporary city, in this case Rome. The Tiber PRT proposal tries to answer the competition questions with the definition of a provocative idea: a Personal Rapid transit System on the Tiber river banks. The project is located in the central section of the Tiber river and aims at the renewal of the river banks with the insertion of a Personal Rapid Transit infrastructure. The project area include the riverbank of Tiber from Rome Transtevere RFI station to Piazza del Popolo, an area where main touristic and leisure attractions are located. The intervention area is actually no used by the city users and residents and constitute itself a strong barrier in the heart of the historic city.

  13. An efficient and accurate 3D displacements tracking strategy for digital volume correlation

    KAUST Repository

    Pan, Bing

    2014-07-01

    Owing to its inherent computational complexity, practical implementation of digital volume correlation (DVC) for internal displacement and strain mapping faces important challenges in improving its computational efficiency. In this work, an efficient and accurate 3D displacement tracking strategy is proposed for fast DVC calculation. The efficiency advantage is achieved by using three improvements. First, to eliminate the need of updating Hessian matrix in each iteration, an efficient 3D inverse compositional Gauss-Newton (3D IC-GN) algorithm is introduced to replace existing forward additive algorithms for accurate sub-voxel displacement registration. Second, to ensure the 3D IC-GN algorithm that converges accurately and rapidly and avoid time-consuming integer-voxel displacement searching, a generalized reliability-guided displacement tracking strategy is designed to transfer accurate and complete initial guess of deformation for each calculation point from its computed neighbors. Third, to avoid the repeated computation of sub-voxel intensity interpolation coefficients, an interpolation coefficient lookup table is established for tricubic interpolation. The computational complexity of the proposed fast DVC and the existing typical DVC algorithms are first analyzed quantitatively according to necessary arithmetic operations. Then, numerical tests are performed to verify the performance of the fast DVC algorithm in terms of measurement accuracy and computational efficiency. The experimental results indicate that, compared with the existing DVC algorithm, the presented fast DVC algorithm produces similar precision and slightly higher accuracy at a substantially reduced computational cost. © 2014 Elsevier Ltd.

  14. Tools for Accurate and Efficient Analysis of Complex Evolutionary Mechanisms in Microbial Genomes. Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Nakhleh, Luay

    2014-03-12

    I proposed to develop computationally efficient tools for accurate detection and reconstruction of microbes' complex evolutionary mechanisms, thus enabling rapid and accurate annotation, analysis and understanding of their genomes. To achieve this goal, I proposed to address three aspects. (1) Mathematical modeling. A major challenge facing the accurate detection of HGT is that of distinguishing between these two events on the one hand and other events that have similar "effects." I proposed to develop a novel mathematical approach for distinguishing among these events. Further, I proposed to develop a set of novel optimization criteria for the evolutionary analysis of microbial genomes in the presence of these complex evolutionary events. (2) Algorithm design. In this aspect of the project, I proposed to develop an array of e cient and accurate algorithms for analyzing microbial genomes based on the formulated optimization criteria. Further, I proposed to test the viability of the criteria and the accuracy of the algorithms in an experimental setting using both synthetic as well as biological data. (3) Software development. I proposed the nal outcome to be a suite of software tools which implements the mathematical models as well as the algorithms developed.

  15. An Efficient Approach for Fast and Accurate Voltage Stability Margin Computation in Large Power Grids

    Directory of Open Access Journals (Sweden)

    Heng-Yi Su

    2016-11-01

    Full Text Available This paper proposes an efficient approach for the computation of voltage stability margin (VSM in a large-scale power grid. The objective is to accurately and rapidly determine the load power margin which corresponds to voltage collapse phenomena. The proposed approach is based on the impedance match-based technique and the model-based technique. It combines the Thevenin equivalent (TE network method with cubic spline extrapolation technique and the continuation technique to achieve fast and accurate VSM computation for a bulk power grid. Moreover, the generator Q limits are taken into account for practical applications. Extensive case studies carried out on Institute of Electrical and Electronics Engineers (IEEE benchmark systems and the Taiwan Power Company (Taipower, Taipei, Taiwan system are used to demonstrate the effectiveness of the proposed approach.

  16. Laser guided automated calibrating system for accurate bracket ...

    African Journals Online (AJOL)

    Background: The basic premise of preadjusted bracket system is accurate bracket positioning. It is widely recognized that accurate bracket placement is of critical importance in the efficient application of biomechanics and in realizing the full potential of a preadjusted edgewise appliance. Aim: The purpose of this study was ...

  17. Accurately Diagnosing Uric Acid Stones from Conventional Computerized Tomography Imaging: Development and Preliminary Assessment of a Pixel Mapping Software.

    Science.gov (United States)

    Ganesan, Vishnu; De, Shubha; Shkumat, Nicholas; Marchini, Giovanni; Monga, Manoj

    2018-02-01

    Preoperative determination of uric acid stones from computerized tomography imaging would be of tremendous clinical use. We sought to design a software algorithm that could apply data from noncontrast computerized tomography to predict the presence of uric acid stones. Patients with pure uric acid and calcium oxalate stones were identified from our stone registry. Only stones greater than 4 mm which were clearly traceable from initial computerized tomography to final composition were included in analysis. A semiautomated computer algorithm was used to process image data. Average and maximum HU, eccentricity (deviation from a circle) and kurtosis (peakedness vs flatness) were automatically generated. These parameters were examined in several mathematical models to predict the presence of uric acid stones. A total of 100 patients, of whom 52 had calcium oxalate and 48 had uric acid stones, were included in the final analysis. Uric acid stones were significantly larger (12.2 vs 9.0 mm, p = 0.03) but calcium oxalate stones had higher mean attenuation (457 vs 315 HU, p = 0.001) and maximum attenuation (918 vs 553 HU, p uric acid stones. A combination of stone size, attenuation intensity and attenuation pattern from conventional computerized tomography can distinguish uric acid stones from calcium oxalate stones with high sensitivity and specificity. Copyright © 2018 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  18. Rapidly variable relatvistic absorption

    Science.gov (United States)

    Parker, M.; Pinto, C.; Fabian, A.; Lohfink, A.; Buisson, D.; Alston, W.; Jiang, J.

    2017-10-01

    I will present results from the 1.5Ms XMM-Newton observing campaign on the most X-ray variable AGN, IRAS 13224-3809. We find a series of nine absorption lines with a velocity of 0.24c from an ultra-fast outflow. For the first time, we are able to see extremely rapid variability of the UFO features, and can link this to the X-ray variability from the inner accretion disk. We find a clear flux dependence of the outflow features, suggesting that the wind is ionized by increasing X-ray emission.

  19. Rapid prototype and test

    Energy Technology Data Exchange (ETDEWEB)

    Gregory, D.L.; Hansche, B.D.

    1996-06-01

    In order to support advanced manufacturing, Sandia has acquired the capability to produce plastic prototypes using stereolithography. Currently, these prototypes are used mainly to verify part geometry and ``fit and form`` checks. This project investigates methods for rapidly testing these plastic prototypes, and inferring from prototype test data actual metal part performance and behavior. Performances examined include static load/stress response, and structural dynamic (modal) and vibration behavior. The integration of advanced non-contacting measurement techniques including scanning laser velocimetry, laser holography, and thermoelasticity into testing of these prototypes is described. Photoelastic properties of the epoxy prototypes to reveal full field stress/strain fields are also explored.

  20. Right-Rapid-Rough

    Science.gov (United States)

    Lawrence, Craig

    2003-01-01

    IDEO (pronounced 'eye-dee-oh') is an international design, engineering, and innovation firm that has developed thousands of products and services for clients across a wide range of industries. Its process and culture attracted the attention of academics, businesses, and journalists around the world, and are the subject of a bestselling book, The Art of Innovation by Tom Kelley. One of the keys to IDEO's success is its use of prototyping as a tool for rapid innovation. This story covers some of IDEO's projects, and gives reasons for why they were successful.

  1. Rapid mineralocorticoid receptor trafficking.

    Science.gov (United States)

    Gekle, M; Bretschneider, M; Meinel, S; Ruhs, S; Grossmann, C

    2014-03-01

    The mineralocorticoid receptor (MR) is a ligand-dependent transcription factor that physiologically regulates water-electrolyte homeostasis and controls blood pressure. The MR can also elicit inflammatory and remodeling processes in the cardiovascular system and the kidneys, which require the presence of additional pathological factors like for example nitrosative stress. However, the underlying molecular mechanism(s) for pathophysiological MR effects remain(s) elusive. The inactive MR is located in the cytosol associated with chaperone molecules including HSP90. After ligand binding, the MR monomer rapidly translocates into the nucleus while still being associated to HSP90 and after dissociation from HSP90 binds to hormone-response-elements called glucocorticoid response elements (GREs) as a dimer. There are indications that rapid MR trafficking is modulated in the presence of high salt, oxidative or nitrosative stress, hypothetically by induction or posttranslational modifications. Additionally, glucocorticoids and the enzyme 11beta hydroxysteroid dehydrogenase may also influence MR activation. Because MR trafficking and its modulation by micro-milieu factors influence MR cellular localization, it is not only relevant for genomic but also for nongenomic MR effects. Copyright © 2013 Elsevier Inc. All rights reserved.

  2. Rapid response manufacturing (RRM)

    Energy Technology Data Exchange (ETDEWEB)

    Cain, W.D. [Lockheed Martin Energy Systems, Inc., Oak Ridge, TN (United States); Waddell, W.L. [National Centers for Manufacturing Sciences, Ann Arbor, MI (United States)

    1997-02-18

    US industry is fighting to maintain its competitive edge in the global market place. Today markets fluctuate rapidly. Companies, to survive, have to be able to respond with quick-to-market, improved, high quality, cost efficient products. The way products are developed and brought to market can be improved and made more efficient through the proper incorporation of emerging technologies. The RRM project was established to leverage the expertise and resources of US private industries and federal agencies to develop, integrate, and deploy new technologies that meet critical needs for effective product realization. The RRM program addressed a needed change in the US Manufacturing infrastructure that will ensure US competitiveness in world market typified by mass customization. This project provided the effort needed to define, develop and establish a customizable infrastructure for rapid response product development design and manufacturing. A major project achievement was the development of a broad-based framework for automating and integrating the product and process design and manufacturing activities involved with machined parts. This was accomplished by coordinating and extending the application of feature-based product modeling, knowledge-based systems, integrated data management, and direct manufacturing technologies in a cooperative integrated computing environment. Key technological advancements include a product model that integrates product and process data in a consistent, minimally redundant manner, an advanced computer-aided engineering environment, knowledge-based software aids for design and process planning, and new production technologies to make products directly from design application software.

  3. Rapid and highly accurate detection of Drosophila suzukii, spotted wing Drosophila (Diptera: Drosophilidae) by loop-mediated isothermal amplification assays

    Science.gov (United States)

    Drosophila suzukii, the spotted wing drosophila (SWD), is currently a major pest that causes severe economic losses to thin-skinned, small fruit growers in North America and Europe. The monitoring and early detection of SWD in the field is of the utmost importance for its proper management. Althou...

  4. Rapid and accurate detection of Cyanobacterial toxin microcystin-LR using fiber-optic long-period grating based immunosensor

    CERN Document Server

    Tripathi, Saurabh Mani; Mikulic, Predrag; Mishra, Garima

    2014-01-01

    In this paper we present a label-free, stable and highly sensitive fiber-optic sensor for detection of environmental toxin microcystin-LR (MC-LR). Thiolated MC-LR-targeting aptamer covalently immobilized on dual-resonance long-period fiber gratings (DR-LPFG) is used as MC-LR recognition element and the spectral response of the DR-LPFG is monitored for various concentrations of MC-LR. Sensitivity of the DR-LPFG is optimized by coating an appropriate thickness of gold layer to the fiber surface. Gold coating serves two purposes, first it locally supports a surface-Plasmon mode associated with the modified cladding modes and second it helps covalently immobilize the MC-LR targeting aptamer to the sensor surface. Monitoring both the resonance wavelengths of our ultra sensitive DR-LPFGs (3891.5 nm/RIU) we study the aptamer and MC-LR binding to the sensor surface. Real-time, efficient MC-LR molecular binding to the sensor surface is also confirmed using atomic force microscopy. The detection limit of our sensor, li...

  5. Direct susceptibility testing by disk diffusion on clinical samples : a rapid and accurate tool for antibiotic stewardship

    NARCIS (Netherlands)

    Coorevits, L.; Boelens, J.; Claeys, G.

    We compared the accuracy of direct susceptibility testing (DST) with conventional antimicrobial susceptibility testing (AST), both using disk diffusion, on clinical samples. A total of 123 clinical samples (respiratory tract samples, urine, vaginal and abdominal abscess discharges, bile fluid and a

  6. Rapid and accurate identification of Streptococcus equi subspecies by MALDI-TOF MS

    DEFF Research Database (Denmark)

    Kudirkiene, Egle; Welker, Martin; Knudsen, Nanna Reumert

    2015-01-01

    Streptococcus equi includes very important animal and human pathogens. S. equi subsp. equi (SEE) is a highly pathogenic equine specific subspecies, while S. equi subsp. zooepidemicus (SEZ) and S. equi subsp. ruminatorum are opportunistic pathogens of various animal species and humans. Due to grea...... with spectra analyses using the SARAMIS database. Additionally, first results on subtyping of SEZ indicated that a more refined discrimination, for example for epidemiological surveys, may be possible...

  7. NASP: an accurate, rapid method for the identification of SNPs in WGS datasets that supports flexible input and output formats.

    Science.gov (United States)

    Sahl, Jason W; Lemmer, Darrin; Travis, Jason; Schupp, James M; Gillece, John D; Aziz, Maliha; Driebe, Elizabeth M; Drees, Kevin P; Hicks, Nathan D; Williamson, Charles Hall Davis; Hepp, Crystal M; Smith, David Earl; Roe, Chandler; Engelthaler, David M; Wagner, David M; Keim, Paul

    2016-08-01

    Whole-genome sequencing (WGS) of bacterial isolates has become standard practice in many laboratories. Applications for WGS analysis include phylogeography and molecular epidemiology, using single nucleotide polymorphisms (SNPs) as the unit of evolution. NASP was developed as a reproducible method that scales well with the hundreds to thousands of WGS data typically used in comparative genomics applications. In this study, we demonstrate how NASP compares with other tools in the analysis of two real bacterial genomics datasets and one simulated dataset. Our results demonstrate that NASP produces similar, and often better, results in comparison with other pipelines, but is much more flexible in terms of data input types, job management systems, diversity of supported tools and output formats. We also demonstrate differences in results based on the choice of the reference genome and choice of inferring phylogenies from concatenated SNPs or alignments including monomorphic positions. NASP represents a source-available, version-controlled, unit-tested method and can be obtained from tgennorth.github.io/NASP.

  8. Rapid and accurate simultaneous determination of abamectin and ivermectin in bovine milk by high performance liquid chromatography with fluorescence detection

    OpenAIRE

    Kolberg, D. I. S.; Presta, M.A.; Wickert, C.; Adaime,M. B.; R. Zanella

    2009-01-01

    An analytical method using high performance liquid chromatography with fluorescence detection for the simultaneous determination of abamectin and ivermectin in bovine milk was developed and validated. The best recovery results were achieved by using acetonitrile for extraction of the compounds followed by solid phase extraction in cartridges containing C18 for the purification of the extract. Pre-column derivatization was accomplished with N-methylimidazole and trifluoroacetic anhydride. The ...

  9. New rapid, accurate T2 quantification detects pathology in normal-appearing brain regions of relapsing-remitting MS patients

    Directory of Open Access Journals (Sweden)

    Timothy M. Shepherd

    2017-01-01

    Conclusions: The EMC algorithm precisely characterizes T2 values, and is able to detect subtle T2 changes in normal-appearing brain regions of RRMS patients. These presumably capture both axon and myelin changes from inflammation and neurodegeneration. Further, T2 variations between different brain regions of healthy controls may correlate with distinct nervous tissue environments that differ from one another at a mesoscopic length-scale.

  10. Accurate submicron edge detection using the phase change of a nano-scale shifting laser spot

    Science.gov (United States)

    Hai, Hoang Hong; Chen, Liang-Chia; Nguyen, Duc Trung; Lin, Shyh-Tsong; Yeh, Sheng Lih; Yao, Ying

    2017-07-01

    Accurate edge detection with lateral super-resolution has been a critical issue in optical measurement because of the barrier imposed by the optical diffraction limit. In this study, a diffraction model that applies scalar diffraction theory of Fresnel-Kirchhoff is developed to simulate phase variance and distribution along edge location. Edge position is detected based on the phase variation that occurs on the edge with a surface step-height jump. To detect accurate edge positioning beyond the optical diffraction limit, a nanopositioning stage is used to scan the super steep edge of a single-edge and multi-edges submicron grating with nano-scale, and its phase distribution is captured. Model simulation is performed to confirm the phase-shifting phenomenon of the edge. A phase-shifting detection algorithm is developed to spatially detect the edge when a finite step scanning with a pitch of several tenth nanometers is used. A 180 nm deviation can occur during detection when the step height of the detecting edge varies, or the detecting laser spot covers more than one edge. Preliminary experimental results show that for the edge detection of the submicron line width of the grating, the standard deviation of the optical phase difference detection measurement is 38 nm. This technique provides a feasible means to achieve optical super-resolution on micro-grating measurement.

  11. esophageal cancer: preliminary results

    Directory of Open Access Journals (Sweden)

    Afsaneh Maddah Safaei

    2017-01-01

    Full Text Available Purpose: Dysphagia is a common initial presentation in locally advanced esophageal cancer and negatively impacts patient quality of life and treatment compliance. To induce fast relief of dysphagia in patients with potentially operable esophageal cancer high-dose-rate (HDR brachytherapy was applied prior to definitive radiochemotherapy. Material and methods : In this single arm phase II clinical trial between 2013 to 2014 twenty patients with locally advanced esophageal cancer (17 squamous cell and 3 adenocarcinoma were treated with upfront 10 Gy HDR brachytherapy, followed by 50.4 Gy external beam radiotherapy (EBRT and concurrent chemotherapy with cisplatin/5-fluorouracil. Results : Tumor response, as measured by endoscopy and/or computed tomography scan, revealed complete remission in 16 and partial response in 4 patients (overall response rate 100%. Improvement of dysphagia was induced by brachytherapy within a few days and maintained up to the end of treatment in 80% of patients. No differences in either response rate or dysphagia resolution were found between squamous cell and adenocarcinoma histology. The grade 2 and 3 acute pancytopenia or bicytopenia reported in 4 patients, while sub-acute adverse effects with painful ulceration was seen in five patients, occurring after a median of 2 months. A perforation developed in one patient during the procedure of brachytherapy that resolved successfully with immediate surgery. Conclusions : Brachytherapy before EBRT was a safe and effective procedure to induce rapid and durable relief from dysphagia, especially when combined with EBRT.

  12. Methods for Rapid Screening in Woody Plant Herbicide Development

    Directory of Open Access Journals (Sweden)

    William Stanley

    2014-07-01

    Full Text Available Methods for woody plant herbicide screening were assayed with the goal of reducing resources and time required to conduct preliminary screenings for new products. Rapid screening methods tested included greenhouse seedling screening, germinal screening, and seed screening. Triclopyr and eight experimental herbicides from Dow AgroSciences (DAS 313, 402, 534, 548, 602, 729, 779, and 896 were tested on black locust, loblolly pine, red maple, sweetgum, and water oak. Screening results detected differences in herbicide and species in all experiments in much less time (days to weeks than traditional field screenings and consumed significantly less resources (<500 mg acid equivalent per herbicide per screening. Using regression analysis, various rapid screening methods were linked into a system capable of rapidly and inexpensively assessing herbicide efficacy and spectrum of activity. Implementation of such a system could streamline early-stage herbicide development leading to field trials, potentially freeing resources for use in development of beneficial new herbicide products.

  13. Accurate vehicle classification including motorcycles using piezoelectric sensors.

    Science.gov (United States)

    2013-03-01

    State and federal departments of transportation are charged with classifying vehicles and monitoring mileage traveled. Accurate data reporting enables suitable roadway design for safety and capacity. Vehicle classifiers currently employ inductive loo...

  14. Digital system accurately controls velocity of electromechanical drive

    Science.gov (United States)

    Nichols, G. B.

    1965-01-01

    Digital circuit accurately regulates electromechanical drive mechanism velocity. The gain and phase characteristics of digital circuits are relatively unimportant. Control accuracy depends only on the stability of the input signal frequency.

  15. Medication errors: the importance of an accurate drug history

    National Research Council Canada - National Science Library

    FitzGerald, Richard J

    2009-01-01

    .... Apart from preventing prescription errors, accurate medication histories are also useful in detecting drug-related pathology or changes in clinical signs that may be the result of drug therapy...

  16. Highly Accurate Sensor for High-Purity Oxygen Determination Project

    Data.gov (United States)

    National Aeronautics and Space Administration — In this STTR effort, Los Gatos Research (LGR) and the University of Wisconsin (UW) propose to develop a highly-accurate sensor for high-purity oxygen determination....

  17. Rapid Refresh (RAP) [13 km

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Rapid Refresh (RAP) numerical weather model took the place of the Rapid Update Cycle (RUC) on May 1, 2012. Run by the National Centers for Environmental...

  18. Rapid Refresh (RAP) [20 km

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Rapid Refresh (RAP) numerical weather model took the place of the Rapid Update Cycle (RUC) on May 1, 2012. Run by the National Centers for Environmental...

  19. Accurate Alignment of Plasma Channels Based on Laser Centroid Oscillations

    Energy Technology Data Exchange (ETDEWEB)

    Gonsalves, Anthony; Nakamura, Kei; Lin, Chen; Osterhoff, Jens; Shiraishi, Satomi; Schroeder, Carl; Geddes, Cameron; Toth, Csaba; Esarey, Eric; Leemans, Wim

    2011-03-23

    A technique has been developed to accurately align a laser beam through a plasma channel by minimizing the shift in laser centroid and angle at the channel outptut. If only the shift in centroid or angle is measured, then accurate alignment is provided by minimizing laser centroid motion at the channel exit as the channel properties are scanned. The improvement in alignment accuracy provided by this technique is important for minimizing electron beam pointing errors in laser plasma accelerators.

  20. Extraction of Accurate Stomach Contour Using Approximated Stomach Region

    OpenAIRE

    小林, 富士男; 尾崎, 誠; コバヤシ, フジオ; オザキ, マコト; Fujio, KOBAYASHI; Makoto, OZAKI

    1999-01-01

    In this paper, the method of stomach extraction is proposed. The stomach contour is automatically and accurately extracted by the characteristics of X-ray image. The approximate stomach is obtained by the combination image which is constructed from binarize of the original image and its differential image. The stomach contour is extracted by the brightness of the differential image and the shape of stomach approximation. The stomach contour is accurately extracted.

  1. Rapid chemical separations

    CERN Document Server

    Trautmann, N

    1976-01-01

    A survey is given on the progress of fast chemical separation procedures during the last few years. Fast, discontinuous separation techniques are illustrated by a procedure for niobium. The use of such techniques for the chemical characterization of the heaviest known elements is described. Other rapid separation methods from aqueous solutions are summarized. The application of the high speed liquid chromatography to the separation of chemically similar elements is outlined. The use of the gas jet recoil transport method for nuclear reaction products and its combination with a continuous solvent extraction technique and with a thermochromatographic separation is presented. Different separation methods in the gas phase are briefly discussed and the attachment of a thermochromatographic technique to an on-line mass separator is shown. (45 refs).

  2. A rapid ultrasound particle agglutination method for HIV antibody detection: Comparison with conventional rapid HIV tests.

    Science.gov (United States)

    Bystryak, Simon; Ossina, Natalya

    2017-11-01

    We present the results of the feasibility and preliminary studies on analytical performance of a rapid test for detection of human immunodeficiency virus (HIV) antibodies in human serum or plasma that is an important advance in detecting HIV infection. Current methods for rapid testing of antibodies against HIV are qualitative and exhibit poor sensitivity (limit of detection). In this paper, we describe an ultrasound particle agglutination (UPA) method that leads to a significant increase of the sensitivity of conventional latex agglutination tests for HIV antibody detection in human serum or plasma. The UPA method is based on the use of: 1) a dual mode ultrasound, wherein a first single-frequency mode is used to accelerate the latex agglutination process, and then a second swept-frequency mode of sonication is used to disintegrate non-specifically bound aggregates; and 2) a numerical assessment of results of the agglutination process. The numerical assessment is carried out by optical detection and analysis of moving patterns in the resonator cell during the swept-frequency mode. The single-step UPA method is rapid and more sensitive than the three commercial rapid HIV test kits analyzed in the study: analytical sensitivity of the new UPA method was found to be 510-, 115-, and 80-fold higher than that for Capillus™, Multispot™ and Uni-Gold™ Recombigen HIV antibody rapid test kits, respectively. The newly developed UPA method opens up additional possibilities for detection of a number of clinically significant markers in point-of-care settings. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Accurate Behavioral Simulator of All-Digital Time-Domain Smart Temperature Sensors by Using SIMULINK

    Directory of Open Access Journals (Sweden)

    Chun-Chi Chen

    2016-08-01

    Full Text Available This study proposes a new behavioral simulator that uses SIMULINK for all-digital CMOS time-domain smart temperature sensors (TDSTSs for performing rapid and accurate simulations. Inverter-based TDSTSs offer the benefits of low cost and simple structure for temperature-to-digital conversion and have been developed. Typically, electronic design automation tools, such as HSPICE, are used to simulate TDSTSs for performance evaluations. However, such tools require extremely long simulation time and complex procedures to analyze the results and generate figures. In this paper, we organize simple but accurate equations into a temperature-dependent model (TDM by which the TDSTSs evaluate temperature behavior. Furthermore, temperature-sensing models of a single CMOS NOT gate were devised using HSPICE simulations. Using the TDM and these temperature-sensing models, a novel simulator in SIMULINK environment was developed to substantially accelerate the simulation and simplify the evaluation procedures. Experiments demonstrated that the simulation results of the proposed simulator have favorable agreement with those obtained from HSPICE simulations, showing that the proposed simulator functions successfully. This is the first behavioral simulator addressing the rapid simulation of TDSTSs.

  4. A rapid, small-scale sedimentation method to predict breadmaking quality of hard winter wheat

    Science.gov (United States)

    Breeders and processors are always looking for rapid and accurate methods to evaluate wheat quality. A rapid small-scale hybrid sedimentation method was developed for predicting breadmaking quality of breeders samples by combining the sodium dodecyl-sulfate (SDS) sedimentation method (AACC 56-70) an...

  5. Malaria rapid diagnostic tests: a revolution and a challenge for the ...

    African Journals Online (AJOL)

    Febrile patients in malaria-endemic areas need rapid and accurate diagnosis to ensure prompt access to antimalarial treatment to avoid severe disease. As most fevers in malaria-endemic areas of South Africa are not caused by malaria, and symptom-based diagnosis is highly nonspecific, rapid demonstration of the ...

  6. Preliminary investigation of an active PLZT lens

    Science.gov (United States)

    Peters, Bruce R.; Reardon, Patrick J.; Wong, K. J.

    2001-05-01

    The design analysis and preliminary testing of a prototype AFOCL is described. The AFOCL is an active optical component composed of solid state lead lanthanum-modified zirconate titanate (PLZT) ferroelectric ceramic with patterned indium tin oxide (ITO) transparent surface electrodes that modulate the refractive index of the PLZT to function as an electro- optic lens. The AFOCL was developed to perform optical re- alignment and wavefront correction to enhance the performance of Ultra-Lightweight Structures and Space Observatories. The AFOCL would be an active optical component within a larger optical system. Information from a wavefront sensor would be processed to provide input to the AFOCL to drive the sense4d wavefront tot he desired shape and location. While offering variable and rapid focusing capability similar to liquid crystal based spatial light modulators, the AFOCL offers some potential advantages because it is a solid-stat, stationary, low-mass, rugged, and thin optical element that can produce wavefront quality comparable to the solid refractive lens it replaces. The AFOCL acts as a positive or negative lens by producing a parabolic phase-shift in the PLZT material through the application of a controlled voltage potential across the ITO electrodes. To demonstrate the technology, a 4 mm diameter lens was fabricated to produce 5-waves of optical power operating at 2.051 micrometers wavelength. Optical metrology was performed on the device to measure focal length, optical quality, and efficiency for a variety of test configurations. Preliminary data was analyzed and compared to idealized performance available from computer-based models of the AFOCL.

  7. Comparison of conventional ultrasonography and ultrasonography-computed tomography fusion imaging for target identification using digital/real hybrid phantoms: a preliminary study.

    Science.gov (United States)

    Soyama, Takeshi; Sakuhara, Yusuke; Kudo, Kohsuke; Abo, Daisuke; Wang, Jeff; Ito, Yoichi M; Hasegawa, Yu; Shirato, Hiroki

    2016-07-01

    This preliminary study compared ultrasonography-computed tomography (US-CT) fusion imaging and conventional ultrasonography (US) for accuracy and time required for target identification using a combination of real phantoms and sets of digitally modified computed tomography (CT) images (digital/real hybrid phantoms). In this randomized prospective study, 27 spheres visible on B-mode US were placed at depths of 3.5, 8.5, and 13.5 cm (nine spheres each). All 27 spheres were digitally erased from the CT images, and a radiopaque sphere was digitally placed at each of the 27 locations to create 27 different sets of CT images. Twenty clinicians were instructed to identify the sphere target using US alone and fusion imaging. The accuracy of target identification of the two methods was compared using McNemar's test. The mean time required for target identification and error distances were compared using paired t tests. At all three depths, target identification was more accurate and the mean time required for target identification was significantly less with US-CT fusion imaging than with US alone, and the mean error distances were also shorter with US-CT fusion imaging. US-CT fusion imaging was superior to US alone in terms of accurate and rapid identification of target lesions.

  8. Toward long-term and accurate augmented-reality for monocular endoscopic videos.

    Science.gov (United States)

    Puerto-Souza, Gustavo A; Cadeddu, Jeffrey A; Mariottini, Gian-Luca

    2014-10-01

    By overlaying preoperative radiological 3-D models onto the intraoperative laparoscopic video, augmented-reality (AR) displays promise to increase surgeons' visual awareness of high-risk surgical targets (e.g., the location of a tumor). Existing AR surgical systems lack in robustness and accuracy because of the many challenges in endoscopic imagery, such as frequent changes in illumination, rapid camera motions, prolonged organ occlusions, and tissue deformations. The frequent occurrence of these events can cause the loss of image (anchor) points, and thus, the loss of the AR display after a few frames. In this paper, we present the design of a new AR system that represents a first step toward long term and accurate augmented surgical display for monocular (calibrated and uncalibrated) endoscopic videos. Our system uses correspondence-search methods, and a new weighted sliding-window registration approach, to automatically and accurately recover the overlay by predicting the image locations of a high number of anchor points that were lost after a sudden image change. The effectiveness of the proposed system in maintaining a long term (over 2 min) and accurate (less than 1 mm) augmentation has been documented over a set of real partial-nephrectomy laparascopic videos.

  9. Breaking Snake Camouflage: Humans Detect Snakes More Accurately than Other Animals under Less Discernible Visual Conditions.

    Directory of Open Access Journals (Sweden)

    Nobuyuki Kawai

    Full Text Available Humans and non-human primates are extremely sensitive to snakes as exemplified by their ability to detect pictures of snakes more quickly than those of other animals. These findings are consistent with the Snake Detection Theory, which hypothesizes that as predators, snakes were a major source of evolutionary selection that favored expansion of the visual system of primates for rapid snake detection. Many snakes use camouflage to conceal themselves from both prey and their own predators, making it very challenging to detect them. If snakes have acted as a selective pressure on primate visual systems, they should be more easily detected than other animals under difficult visual conditions. Here we tested whether humans discerned images of snakes more accurately than those of non-threatening animals (e.g., birds, cats, or fish under conditions of less perceptual information by presenting a series of degraded images with the Random Image Structure Evolution technique (interpolation of random noise. We find that participants recognize mosaic images of snakes, which were regarded as functionally equivalent to camouflage, more accurately than those of other animals under dissolved conditions. The present study supports the Snake Detection Theory by showing that humans have a visual system that accurately recognizes snakes under less discernible visual conditions.

  10. Breaking Snake Camouflage: Humans Detect Snakes More Accurately than Other Animals under Less Discernible Visual Conditions.

    Science.gov (United States)

    Kawai, Nobuyuki; He, Hongshen

    2016-01-01

    Humans and non-human primates are extremely sensitive to snakes as exemplified by their ability to detect pictures of snakes more quickly than those of other animals. These findings are consistent with the Snake Detection Theory, which hypothesizes that as predators, snakes were a major source of evolutionary selection that favored expansion of the visual system of primates for rapid snake detection. Many snakes use camouflage to conceal themselves from both prey and their own predators, making it very challenging to detect them. If snakes have acted as a selective pressure on primate visual systems, they should be more easily detected than other animals under difficult visual conditions. Here we tested whether humans discerned images of snakes more accurately than those of non-threatening animals (e.g., birds, cats, or fish) under conditions of less perceptual information by presenting a series of degraded images with the Random Image Structure Evolution technique (interpolation of random noise). We find that participants recognize mosaic images of snakes, which were regarded as functionally equivalent to camouflage, more accurately than those of other animals under dissolved conditions. The present study supports the Snake Detection Theory by showing that humans have a visual system that accurately recognizes snakes under less discernible visual conditions.

  11. Building a rapid response team.

    Science.gov (United States)

    Halvorsen, Lisa; Garolis, Salomeja; Wallace-Scroggs, Allyson; Stenstrom, Judy; Maunder, Richard

    2007-01-01

    The use of rapid response teams is a relatively new approach for decreasing or eliminating codes in acute care hospitals. Based on the principles of a code team for cardiac and/or respiratory arrest in non-critical care units, the rapid response teams have specially trained nursing, respiratory, and medical personnel to respond to calls from general care units to assess and manage decompensating or rapidly changing patients before their conditions escalate to a full code situation. This article describes the processes used to develop a rapid response team, clinical indicators for triggering a rapid response team call, topics addressed in an educational program for the rapid response team members, and methods for evaluating effectiveness of the rapid response team.

  12. Preliminary investigations of Agrobacterium -mediated ...

    African Journals Online (AJOL)

    Preliminary steps in the genetic transformation of indica rice MR219 was investigated in the plant- Agrobacterium tumefaciens interaction. Agrobacterium tumefaciens strain LBA 4404 carrying a binary vector pCAMBIA 1305.2 harboring the modified GUS gene driven by the CaMV 35S promoter was used. Various ...

  13. Preliminary test-shrinkage estimators

    Directory of Open Access Journals (Sweden)

    H. H. Lemmer

    1983-03-01

    Full Text Available The advantages of using the very simple shrinkage estimator TL proposed by Lemmer rather than that proposed by Mehta and Srivivasan in the case of preliminary test estimators for parameters of the normal, binomial and Poisson distributions are examined.

  14. Problems of rapid growth.

    Science.gov (United States)

    Kim, T D

    1980-01-01

    South Korea's export-oriented development strategy has achieved a remarkable growth record, but it has also brought 2 different problems: 1) since the country's exports accounted for about 1% of total world export volume, the 1st world has become fearful about Korea's aggressive export drive; and 2) the fact that exports account for over 30% of its total gross national product (GNP) exposes the vulnerability of South Korea's economy itself. South Korea continues to be a poor nation, although it is rated as 1 of the most rapidly growing middle income economies. A World Bank 1978 report shows Korea to be 28th of 58 middle income countries in terms of per capita GNP in 1976. Of 11 newly industrializing countries (NIC), 5 in the European continent are more advanced than the others. A recent emphasis on the basic human needs approach has tended to downgrade the concept of GNP. Korea has only an abundant labor force and is without any natural resources. Consequently, Korea utilized an export-oriented development strategy. Oil requirements are met with imports, and almost all raw materials to be processed into exportable products must be imported. To pay import bills Korea must export and earn foreign exchange. It must be emphasized that foreign trade must always be 2-way traffic. In order to export more to middle income countries like Korea, the countries of the 1st world need to ease their protectionist measures against imports from developing countries.

  15. Rapidly rotating red giants

    Science.gov (United States)

    Gehan, Charlotte; Mosser, Benoît; Michel, Eric

    2017-10-01

    Stellar oscillations give seismic information on the internal properties of stars. Red giants are targets of interest since they present mixed modes, wich behave as pressure modes in the convective envelope and as gravity modes in the radiative core. Mixed modes thus directly probe red giant cores, and allow in particular the study of their mean core rotation. The high-quality data obtained by CoRoT and Kepler satellites represent an unprecedented perspective to obtain thousands of measurements of red giant core rotation, in order to improve our understanding of stellar physics in deep stellar interiors. We developed an automated method to obtain such core rotation measurements and validated it for stars on the red giant branch. In this work, we particularly focus on the specific application of this method to red giants having a rapid core rotation. They show complex spectra where it is tricky to disentangle rotational splittings from mixed-mode period spacings. We demonstrate that the method based on the identification of mode crossings is precise and efficient. The determination of the mean core rotation directly derives from the precise measurement of the asymptotic period spacing ΔΠ1 and of the frequency at which the crossing of the rotational components is observed.

  16. Nonexposure Accurate Location K-Anonymity Algorithm in LBS

    Directory of Open Access Journals (Sweden)

    Jinying Jia

    2014-01-01

    Full Text Available This paper tackles location privacy protection in current location-based services (LBS where mobile users have to report their exact location information to an LBS provider in order to obtain their desired services. Location cloaking has been proposed and well studied to protect user privacy. It blurs the user’s accurate coordinate and replaces it with a well-shaped cloaked region. However, to obtain such an anonymous spatial region (ASR, nearly all existent cloaking algorithms require knowing the accurate locations of all users. Therefore, location cloaking without exposing the user’s accurate location to any party is urgently needed. In this paper, we present such two nonexposure accurate location cloaking algorithms. They are designed for K-anonymity, and cloaking is performed based on the identifications (IDs of the grid areas which were reported by all the users, instead of directly on their accurate coordinates. Experimental results show that our algorithms are more secure than the existent cloaking algorithms, need not have all the users reporting their locations all the time, and can generate smaller ASR.

  17. Nonexposure accurate location K-anonymity algorithm in LBS.

    Science.gov (United States)

    Jia, Jinying; Zhang, Fengli

    2014-01-01

    This paper tackles location privacy protection in current location-based services (LBS) where mobile users have to report their exact location information to an LBS provider in order to obtain their desired services. Location cloaking has been proposed and well studied to protect user privacy. It blurs the user's accurate coordinate and replaces it with a well-shaped cloaked region. However, to obtain such an anonymous spatial region (ASR), nearly all existent cloaking algorithms require knowing the accurate locations of all users. Therefore, location cloaking without exposing the user's accurate location to any party is urgently needed. In this paper, we present such two nonexposure accurate location cloaking algorithms. They are designed for K-anonymity, and cloaking is performed based on the identifications (IDs) of the grid areas which were reported by all the users, instead of directly on their accurate coordinates. Experimental results show that our algorithms are more secure than the existent cloaking algorithms, need not have all the users reporting their locations all the time, and can generate smaller ASR.

  18. Preliminary Outcomes from an Integrated Pediatric Mental Health Outpatient Clinic.

    Science.gov (United States)

    Maslow, Gary R; Banny, Adrienne; Pollock, McLean; Stefureac, Kristen; Rosa, Kendra; Walter, Barbara Keith; Hobbs Knutson, Katherine; Lucas, Joseph; Heilbron, Nicole

    2017-10-01

    An estimated 1 in 5 children in the United States meet criteria for a diagnosable mental disorder, yet fewer than 20% receive mental health services. Unmet need for psychiatric treatment may contribute to patterns of increasing use of the emergency department. This article describes an integrated pediatric evaluation center designed to prevent the need for treatment in emergency settings by increasing access to timely and appropriate care for emergent and critical mental health needs. Preliminary results showed that the center provided rapid access to assessment and treatment services for children and adolescents presenting with a wide range of psychiatric concerns. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. A New Accurate Finite-Difference Scheme Based on the Optimally Accurate Operators and Boundary-Condition Consistent Material Parameterization

    Science.gov (United States)

    Kristek, J.; Moczo, P.; Galis, M.

    2005-12-01

    Geller and Takeuchi (1995) developed optimally accurate finite-difference (FD) operators. The operators minimize the error of the numerical solution of the discretized equation of motion. The criterion for obtaining the optimally accurate operators requires that the leading term of the truncation error of the discretized homogeneous (without body-force term) equation of motion (that is if operand is an eigenfunction and frequency is equal to eigenfrequency) is zero. Consequently, the optimally accurate operators satisfy (up to the leading term of the truncation error) homogeneous equation of motion. The grid dispersion of an optimally accurate FD scheme is significantly smaller than that of a standard FD scheme. A heterogeneous FD scheme cannot be anything else than a FD approximation to the heterogeneous formulation of the equation of motion (the same form of the equation for a point away from a material discontinuity and a point at the material discontinuity). If an optimally accurate FD scheme for heterogeneous media is to be obtained, the optimally accurate operators have to be applied to the heterogeneous formulation of the equation of motion. Moczo et al. (2002) found a heterogeneous formulation and developed a FD scheme based on standard staggered-grid 4th-order operators. The scheme is capable to sense both smooth material heterogeneity and material discontinuity at any position in a spatial grid. We present a new FD scheme that combines optimally accurate operators of Geller and Takeuchi (1995) with a material parameterization of Moczo et al. (2002). Models of a single material discontinuity, interior constant-velocity layer, and interior layer with the velocity gradient were calculated with the new scheme, conventional-operator scheme and analytically. Numerical results clearly isolate and demonstrate effects of the boundary and grid dispersion. The results demonstrate significant accuracy improvement compared to previous FD schemes.

  20. Fast and accurate computation of projected two-point functions

    Science.gov (United States)

    Grasshorn Gebhardt, Henry S.; Jeong, Donghui

    2018-01-01

    We present the two-point function from the fast and accurate spherical Bessel transformation (2-FAST) algorithm1Our code is available at https://github.com/hsgg/twoFAST. for a fast and accurate computation of integrals involving one or two spherical Bessel functions. These types of integrals occur when projecting the galaxy power spectrum P (k ) onto the configuration space, ξℓν(r ), or spherical harmonic space, Cℓ(χ ,χ'). First, we employ the FFTLog transformation of the power spectrum to divide the calculation into P (k )-dependent coefficients and P (k )-independent integrations of basis functions multiplied by spherical Bessel functions. We find analytical expressions for the latter integrals in terms of special functions, for which recursion provides a fast and accurate evaluation. The algorithm, therefore, circumvents direct integration of highly oscillating spherical Bessel functions.

  1. Accurate intelligence assessments in social interactions: mediators and gender effects.

    Science.gov (United States)

    Murphy, Nora A; Hall, Judith A; Colvin, C Randal

    2003-06-01

    Research indicates that people can assess a stranger's measured intelligence more accurately than expected by chance, based on minimal information involving appearance and behavior. The present research documents behavioral correlates of perceived and measured intelligence and identifies behaviors that mediate the relationship between perceived and measured intelligence. In particular, when judges rated targets with video and auditory stimuli available, responsiveness to conversation partner, eye-gaze, and looking at partner while speaking were each significant mediators in the accurate assessment of intelligence. Each of those behaviors, as well as the percentage of looking at partner while speaking as a function of the target's own speaking time, were significant mediators in the video silent condition. Additionally, judge and target gender contributed to accurate intelligence assessments.

  2. Accurate Astrometry of 22 Southern Hemisphere Radio Sources

    Science.gov (United States)

    Fey, Alan L.; Ojha, Roopesh; Jauncey, David L.; Johnston, Kenneth J.; Reynolds, John E.; Lovell, James E. J.; Tzioumis, Anastasios K.; Quick, Jonathan F. H.; Nicolson, George D.; Ellingsen, Simon P.; McCulloch, Peter M.; Koyama, Yasuhiro

    2004-03-01

    Milliarcsecond-accurate radio positions for 22 southern hemisphere extragalactic sources are reported. These positions are derived from Mark III very long baseline interferometry observations made between 2003 February and 2003 August. The results presented here supplement an ongoing project to increase the sky density of southern hemisphere sources in order to better define the International Celestial Reference Frame and to provide additional phase-reference sources with accurate positions for use in astrophysical observations. The positions for all 22 sources are south of δ=-30° (positions for 10 of the sources are south of δ=-60°) and represent the largest group of new milliarcsecond-accurate astrometric positions for sources in this declination range since the initial definition of the International Celestial Reference Frame. The reported positions have average formal uncertainties of 0.5 mas in right ascension and 0.6 mas in declination.

  3. Memory conformity affects inaccurate memories more than accurate memories.

    Science.gov (United States)

    Wright, Daniel B; Villalba, Daniella K

    2012-01-01

    After controlling for initial confidence, inaccurate memories were shown to be more easily distorted than accurate memories. In two experiments groups of participants viewed 50 stimuli and were then presented with these stimuli plus 50 fillers. During this test phase participants reported their confidence that each stimulus was originally shown. This was followed by computer-generated responses from a bogus participant. After being exposed to this response participants again rated the confidence of their memory. The computer-generated responses systematically distorted participants' responses. Memory distortion depended on initial memory confidence, with uncertain memories being more malleable than confident memories. This effect was moderated by whether the participant's memory was initially accurate or inaccurate. Inaccurate memories were more malleable than accurate memories. The data were consistent with a model describing two types of memory (i.e., recollective and non-recollective memories), which differ in how susceptible these memories are to memory distortion.

  4. Rapid mixing kinetic techniques.

    Science.gov (United States)

    Martin, Stephen R; Schilstra, Maria J

    2013-01-01

    Almost all of the elementary steps in a biochemical reaction scheme are either unimolecular or bimolecular processes that frequently occur on sub-second, often sub-millisecond, time scales. The traditional approach in kinetic studies is to mix two or more reagents and monitor the changes in concentrations with time. Conventional spectrophotometers cannot generally be used to study reactions that are complete within less than about 20 s, as it takes that amount of time to manually mix the reagents and activate the instrument. Rapid mixing techniques, which generally achieve mixing in less than 2 ms, overcome this limitation. This chapter is concerned with the use of these techniques in the study of reactions which reach equilibrium; the application of these methods to the study of enzyme kinetics is described in several excellent texts (Cornish-Bowden, Fundamentals of enzyme kinetics. Portland Press, 1995; Gutfreund, Kinetics for the life sciences. Receptors, transmitters and catalysis. Cambridge University Press, 1995).There are various ways to monitor changes in concentration of reactants, intermediates and products after mixing, but the most common way is to use changes in optical signals (absorbance or fluorescence) which often accompany reactions. Although absorbance can sometimes be used, fluorescence is often preferred because of its greater sensitivity, particularly in monitoring conformational changes. Such methods are continuous with good time resolution but they seldom permit the direct determination of the concentrations of individual species. Alternatively, samples may be taken from the reaction volume, mixed with a chemical quenching agent to stop the reaction, and their contents assessed by techniques such as HPLC. These methods can directly determine the concentrations of different species, but are discontinuous and have a limited time resolution.

  5. Accelerated training for accurate neural net based load forecasting

    Energy Technology Data Exchange (ETDEWEB)

    Borsje, H.J.; Ling, B. [Stone and Webster Advanced Systems Development Services, Inc., Boston, MA (United States)

    1995-10-01

    A fast, accurate, robust and reliable load forecast method was developed, tested and demonstrated. The achieved prediction accuracy, based on a practical input parameters, matches or exceeds that of currently used methods. The time required to train the system is orders of magnitude shorter than other methods. This gives utility personnel the tools to refine local forecasts by quickly evaluating the effect of user selectable parameters. The conventional back propagation method can accurately predict the adaptive one-hour ahead forecast with reasonable learning requirements.

  6. Rapid induction of false memory for pictures.

    Science.gov (United States)

    Weinstein, Yana; Shanks, David R

    2010-07-01

    Recognition of pictures is typically extremely accurate, and it is thus unclear whether the reconstructive nature of memory can yield substantial false recognition of highly individuated stimuli. A procedure for the rapid induction of false memories for distinctive colour photographs is proposed. Participants studied a set of object pictures followed by a list of words naming those objects, but embedded in the list were names of unseen objects. When subsequently shown full colour pictures of these unseen objects, participants consistently claimed that they had seen them, while discriminating with high accuracy between studied pictures and new pictures whose names did not appear in the misleading word list. These false memories can be reported with high confidence as well as the feeling of recollection. This new procedure allows the investigation of factors that influence false memory reports with ecologically valid stimuli and of the similarities and differences between true and false memories.

  7. Rapid inactivation of SARS-like coronaviruses.

    Energy Technology Data Exchange (ETDEWEB)

    Kapil, Sanjay (Kansas State University, Manhattan, KS); Oberst, R. D. (Kansas State University, Manhattan, KS); Bieker, Jill Marie; Tucker, Mark David; Souza, Caroline Ann; Williams, Cecelia Victoria

    2004-03-01

    Chemical disinfection and inactivation of viruses is largely understudied, but is very important especially in the case of highly infectious viruses. The purpose of this LDRD was to determine the efficacy of the Sandia National Laboratories developed decontamination formulations against Bovine Coronavirus (BCV) as a surrogate for the coronavirus that causes Severe Acute Respiratory Syndrome (SARS) in humans. The outbreak of SARS in late 2002 resulted from a highly infectious virus that was able to survive and remain infectious for extended periods. For this study, preliminary testing with Escherichia coli MS-2 (MS-2) and Escherichia coli T4 (T4) bacteriophages was conducted to develop virucidal methodology for verifying the inactivation after treatment with the test formulations following AOAC germicidal methodologies. After the determination of various experimental parameters (i.e. exposure, concentration) of the formulations, final testing was conducted on BCV. All experiments were conducted with various organic challenges (horse serum, bovine feces, compost) for results that more accurately represent field use condition. The MS-2 and T4 were slightly more resistant than BCV and required a 2 minute exposure while BCV was completely inactivated after a 1 minute exposure. These results were also consistent for the testing conducted in the presence of the various organic challenges indicating that the test formulations are highly effective for real world application.

  8. Desorption electrospray ionisation mass spectrometry: A rapid screening tool for veterinary drug preparations and forensic samples from hormone crime investigations

    Energy Technology Data Exchange (ETDEWEB)

    Nielen, M.W.F. [RIKILT Institute of Food Safety, P.O. Box 230, 6700 AE Wageningen (Netherlands); Wageningen University, Laboratory of Organic Chemistry, Dreijenplein 8, 6703 HB Wageningen (Netherlands)], E-mail: michel.nielen@wur.nl; Hooijerink, H. [RIKILT Institute of Food Safety, P.O. Box 230, 6700 AE Wageningen (Netherlands); Claassen, F.C. [Wageningen University, Laboratory of Organic Chemistry, Dreijenplein 8, 6703 HB Wageningen (Netherlands); Engelen, M.C. van [RIKILT Institute of Food Safety, P.O. Box 230, 6700 AE Wageningen (Netherlands); Beek, T.A. van [Wageningen University, Laboratory of Organic Chemistry, Dreijenplein 8, 6703 HB Wageningen (Netherlands)

    2009-04-01

    Hormone and veterinary drug screening and forensics can benefit from the recent developments in desorption electrospray ionisation (DESI) mass spectrometry (MS). In this work the feasibility of DESI application has been studied. Using a linear ion trap or quadrupole time-of-flight (TOF) MS instrument both full-scan and data-dependent collision-induced dissociation MS{sup n} spectra were acquired in seconds without sample preparation. Preliminary data are presented for the rapid screening of (pro)hormone supplement samples, an illegal steroid cocktail and forensic samples from veterinary drug investigations. The potential of this DESI approach is clearly demonstrated since compounds observed could be independently confirmed by liquid chromatography/TOFMS with accurate mass measurement, and/or proton nuclear magnetic resonance spectroscopy. Specific concerns related to false-positive and false-negative findings due to limitations in quantification and memory-effects are briefly discussed. It is envisaged that DESI will achieve a prominent role in hormone and veterinary drug analysis in the near future.

  9. Rapid Active Sampling Package

    Science.gov (United States)

    Peters, Gregory

    2010-01-01

    A field-deployable, battery-powered Rapid Active Sampling Package (RASP), originally designed for sampling strong materials during lunar and planetary missions, shows strong utility for terrestrial geological use. The technology is proving to be simple and effective for sampling and processing materials of strength. Although this originally was intended for planetary and lunar applications, the RASP is very useful as a powered hand tool for geologists and the mining industry to quickly sample and process rocks in the field on Earth. The RASP allows geologists to surgically acquire samples of rock for later laboratory analysis. This tool, roughly the size of a wrench, allows the user to cut away swaths of weathering rinds, revealing pristine rock surfaces for observation and subsequent sampling with the same tool. RASPing deeper (.3.5 cm) exposes single rock strata in-situ. Where a geologist fs hammer can only expose unweathered layers of rock, the RASP can do the same, and then has the added ability to capture and process samples into powder with particle sizes less than 150 microns, making it easier for XRD/XRF (x-ray diffraction/x-ray fluorescence). The tool uses a rotating rasp bit (or two counter-rotating bits) that resides inside or above the catch container. The container has an open slot to allow the bit to extend outside the container and to allow cuttings to enter and be caught. When the slot and rasp bit are in contact with a substrate, the bit is plunged into it in a matter of seconds to reach pristine rock. A user in the field may sample a rock multiple times at multiple depths in minutes, instead of having to cut out huge, heavy rock samples for transport back to a lab for analysis. Because of the speed and accuracy of the RASP, hundreds of samples can be taken in one day. RASP-acquired samples are small and easily carried. A user can characterize more area in less time than by using conventional methods. The field-deployable RASP used a Ni

  10. Rapid Robot Design Validation Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Energid Technologies will create a comprehensive software infrastructure for rapid validation of robotic designs. The software will support push-button validation...

  11. Rapid Robot Design Validation Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Energid Technologies will create a comprehensive software infrastructure for rapid validation of robot designs. The software will support push-button validation...

  12. The dilemma of malaria diagnosis: How accurate are the diagnostic ...

    African Journals Online (AJOL)

    The dilemma of malaria diagnosis: How accurate are the diagnostic tools? ... Materials and Methods: This is a descriptive, cross-sectional hospital-based study, conducted at the casualty of Atbara Hospital, in January 2011. Any patient clinically suspected to have malaria in this month was included. Demographic and ...

  13. Adaptive through-thickness integration for accurate springback prediction

    NARCIS (Netherlands)

    Burchitz, I.A.; Meinders, Vincent T.

    2007-01-01

    Accurate numerical prediction of springback in sheet metal forming is essential for the automotive industry. Numerous factors influence the accuracy of prediction of this complex phenomenon by using the finite element method. One of them is the numerical integration through the thickness of shell

  14. On a more accurate Hardy-Mulholland-type inequality

    Directory of Open Access Journals (Sweden)

    Bicheng Yang

    2016-03-01

    Full Text Available Abstract By using weight coefficients, technique of real analysis, and Hermite-Hadamard’s inequality, we give a more accurate Hardy-Mulholland-type inequality with multiparameters and a best possible constant factor related to the beta function. The equivalent forms, the reverses, the operator expressions, and some particular cases are also considered.

  15. MSmetrix: accurate untrained method for longitudinal lesion segmentation

    OpenAIRE

    Jain, Saurabh; Sima, Diana; Maertens, Anke; Van Huffel, Sabine; Maes, Frederik; Smeets, Dirk

    2015-01-01

    Jain S., Sima D.M., Maertens A., Van Huffel S., Maes F., Smeets D., ''MSmetrix: accurate untrained method for longitudinal lesion segmentation'', Multiple sclerosis journal, vol. 21 (S11), pp. 193-194, 2015 (31th congress of the European Committee for Treatment and Reseach in Multiple Sclerosis (ECTRIMS), October 7-10, 2015, Barcelona, Spain).

  16. Nonlinear oscillations of laminated plates using an accurate four ...

    Indian Academy of Sciences (India)

    Abstract. The objective of the present paper is to investigate the large amplitude vibratory behaviour of unsymmetrically laminated plates. For this purpose, an efficient and accurate four-node shear flexible rectangular material finite element (MFE) with six degrees of freedom per node (three displacements. (uY vY w) along ...

  17. Improved fingercode alignment for accurate and compact fingerprint recognition

    CSIR Research Space (South Africa)

    Brown, Dane

    2016-05-01

    Full Text Available The traditional texture-based fingerprint recognition system known as FingerCode is improved in this work. Texture-based fingerprint recognition methods are generally more accurate than other methods, but at the disadvantage of increased storage...

  18. Accurate determination of selenium and iron in erythrocytes from ...

    African Journals Online (AJOL)

    Accurate determination of selenium and iron in erythrocytes from Nigeria subjects using INAA. JO Ojo, Jan Kucera. Abstract. Levels of two essential elements playing crucial roles in erythrocyte's structure and functions, iron and selenium, have been carefully determined in 36 erythrocyte samples drawn from two healthy ...

  19. Precise and Accurate Density Determination of Explosives Using Hydrostatic Weighing

    Energy Technology Data Exchange (ETDEWEB)

    B. Olinger

    2005-07-01

    Precise and accurate density determination requires weight measurements in air and water using sufficiently precise analytical balances, knowledge of the densities of air and water, knowledge of thermal expansions, availability of a density standard, and a method to estimate the time to achieve thermal equilibrium with water. Density distributions in pressed explosives are inferred from the densities of elements from a central slice.

  20. Accurate conjugate gradient methods for families of shifted systems

    NARCIS (Netherlands)

    Eshof, J. van den; Sleijpen, G.L.G.

    We present an efficient and accurate variant of the conjugate gradient method for solving families of shifted systems. In particular we are interested in shifted systems that occur in Tikhonov regularization for inverse problems since these problems can be sensitive to roundoff errors. The

  1. Foresight begins with FMEA. Delivering accurate risk assessments.

    Science.gov (United States)

    Passey, R D

    1999-03-01

    If sufficient factors are taken into account and two- or three-stage analysis is employed, failure mode and effect analysis represents an excellent technique for delivering accurate risk assessments for products and processes, and for relating them to legal liability. This article describes a format that facilitates easy interpretation.

  2. A Simple and Accurate Method for Measuring Enzyme Activity.

    Science.gov (United States)

    Yip, Din-Yan

    1997-01-01

    Presents methods commonly used for investigating enzyme activity using catalase and presents a new method for measuring catalase activity that is more reliable and accurate. Provides results that are readily reproduced and quantified. Can also be used for investigations of enzyme properties such as the effects of temperature, pH, inhibitors,…

  3. Dense and accurate whole-chromosome haplotyping of individual genomes

    NARCIS (Netherlands)

    Porubsky, David; Garg, Shilpa; Sanders, Ashley D.; Korbel, Jan O.; Guryev, Victor; Lansdorp, Peter M.; Marschall, Tobias

    2017-01-01

    The diploid nature of the human genome is neglected in many analyses done today, where a genome is perceived as a set of unphased variants with respect to a reference genome. This lack of haplotype-level analyses can be explained by a lack of methods that can produce dense and accurate

  4. Fast, Accurate and Detailed NoC Simulations

    NARCIS (Netherlands)

    Wolkotte, P.T.; Holzenspies, P.K.F.; Smit, Gerardus Johannes Maria; Kellenberger, P.

    Network-on-Chip (NoC) architectures have a wide variety of parameters that can be adapted to the designer's requirements. Fast exploration of this parameter space is only possible at a high-level and several methods have been proposed. Cycle and bit accurate simulation is necessary when the actual

  5. Laser Guided Automated Calibrating System for Accurate Bracket ...

    African Journals Online (AJOL)

    It is widely recognized that accurate bracket placement is of critical importance in the efficient application of biomechanics and in realizing the full potential of a preadjusted edgewise appliance. When bands were used originally, Angle[1] thought the best position to place the bracket was at the center of the tooth.

  6. Toward more accurate loss tangent measurements in reentrant cavities

    Energy Technology Data Exchange (ETDEWEB)

    Moyer, R. D.

    1980-05-01

    Karpova has described an absolute method for measurement of dielectric properties of a solid in a coaxial reentrant cavity. His cavity resonance equation yields very accurate results for dielectric constants. However, he presented only approximate expressions for the loss tangent. This report presents more exact expressions for that quantity and summarizes some experimental results.

  7. Fast and Accurate Residential Fire Detection Using Wireless Sensor Networks

    NARCIS (Netherlands)

    Bahrepour, M.; Meratnia, Nirvana; Havinga, Paul J.M.

    2010-01-01

    Prompt and accurate residential fire detection is important for on-time fire extinguishing and consequently reducing damages and life losses. To detect fire sensors are needed to measure the environmental parameters and algorithms are required to decide about occurrence of fire. Recently, wireless

  8. Is Expressive Language Disorder an Accurate Diagnostic Category?

    Science.gov (United States)

    Leonard, Laurence B.

    2009-01-01

    Purpose: To propose that the diagnostic category of "expressive language disorder" as distinct from a disorder of both expressive and receptive language might not be accurate. Method: Evidence that casts doubt on a pure form of this disorder is reviewed from several sources, including the literature on genetic findings, theories of language…

  9. Using the micro to accurately allocate a hospital's departmental overhead.

    Science.gov (United States)

    Linder, C A

    1986-02-01

    A major component of standard costing is overhead allocation. Unfortunately, overhead allocation can be complex and difficult. But, at one hospital, this problem was solved with a microcomputer-based technique. The technique, using the spreadsheet Lotus 1-2-3, was logical, simple, and technically sound, allowing the financial manager to more accurately allocate overhead in the standard costing process.

  10. Novel multi-beam radiometers for accurate ocean surveillance

    DEFF Research Database (Denmark)

    Cappellin, C.; Pontoppidan, K.; Nielsen, P. H.

    2014-01-01

    Novel antenna architectures for real aperture multi-beam radiometers providing high resolution and high sensitivity for accurate sea surface temperature (SST) and ocean vector wind (OVW) measurements are investigated. On the basis of the radiometer requirements set for future SST/OVW missions...

  11. Quantifying Accurate Calorie Estimation Using the "Think Aloud" Method

    Science.gov (United States)

    Holmstrup, Michael E.; Stearns-Bruening, Kay; Rozelle, Jeffrey

    2013-01-01

    Objective: Clients often have limited time in a nutrition education setting. An improved understanding of the strategies used to accurately estimate calories may help to identify areas of focused instruction to improve nutrition knowledge. Methods: A "Think Aloud" exercise was recorded during the estimation of calories in a standard dinner meal…

  12. Dynamic weighing for accurate fertilizer application and monitoring

    NARCIS (Netherlands)

    Bergeijk, van J.; Goense, D.; Willigenburg, van L.G.; Speelman, L.

    2001-01-01

    The mass flow of fertilizer spreaders must be calibrated for the different types of fertilizers used. To obtain accurate fertilizer application manual calibration of actual mass flow must be repeated frequently. Automatic calibration is possible by measurement of the actual mass flow, based on

  13. Electronic ampere-hour integrator is accurate to one percent

    Science.gov (United States)

    Paulkovich, J.

    1965-01-01

    Electronic ampere-hour integrator is based on current-to-frequency conversion. It operates on low power and is accurate to one percent. This device can measure the ampere-hour capacity of batteries and can be adapted for other functions.

  14. Low-dimensional, morphologically accurate models of subthreshold membrane potential

    Science.gov (United States)

    Kellems, Anthony R.; Roos, Derrick; Xiao, Nan; Cox, Steven J.

    2009-01-01

    The accurate simulation of a neuron’s ability to integrate distributed synaptic input typically requires the simultaneous solution of tens of thousands of ordinary differential equations. For, in order to understand how a cell distinguishes between input patterns we apparently need a model that is biophysically accurate down to the space scale of a single spine, i.e., 1 μm. We argue here that one can retain this highly detailed input structure while dramatically reducing the overall system dimension if one is content to accurately reproduce the associated membrane potential at a small number of places, e.g., at the site of action potential initiation, under subthreshold stimulation. The latter hypothesis permits us to approximate the active cell model with an associated quasi-active model, which in turn we reduce by both time-domain (Balanced Truncation) and frequency-domain (ℋ2 approximation of the transfer function) methods. We apply and contrast these methods on a suite of typical cells, achieving up to four orders of magnitude in dimension reduction and an associated speed-up in the simulation of dendritic democratization and resonance. We also append a threshold mechanism and indicate that this reduction has the potential to deliver an accurate quasi-integrate and fire model. PMID:19172386

  15. Ultra-Rapid Vision in Birds.

    Directory of Open Access Journals (Sweden)

    Jannika E Boström

    Full Text Available Flying animals need to accurately detect, identify and track fast-moving objects and these behavioral requirements are likely to strongly select for abilities to resolve visual detail in time. However, evidence of highly elevated temporal acuity relative to non-flying animals has so far been confined to insects while it has been missing in birds. With behavioral experiments on three wild passerine species, blue tits, collared and pied flycatchers, we demonstrate temporal acuities of vision far exceeding predictions based on the sizes and metabolic rates of these birds. This implies a history of strong natural selection on temporal resolution. These birds can resolve alternating light-dark cycles at up to 145 Hz (average: 129, 127 and 137, respectively, which is ca. 50 Hz over the highest frequency shown in any other vertebrate. We argue that rapid vision should confer a selective advantage in many bird species that are ecologically similar to the three species examined in our study. Thus, rapid vision may be a more typical avian trait than the famously sharp vision found in birds of prey.

  16. Rapid precision casting for complex thin-walled aluminum alloy parts

    Directory of Open Access Journals (Sweden)

    Xuanpu DONG

    2004-11-01

    Full Text Available Based on Vacuum Differential Pressure Casting (VDPC precision forming technology and the Selective Laser Sintering (SLS Rapid Prototyping (RP technology, a rapid manufacturing method called Rapid Precision Casting (RPC process from computer three-dimensional solid models to metallic parts was investigated. The experimental results showed that the main advantage of RPC was not only its ability to cast higher internal quality and more accurate complex thin-walled aluminum alloy parts, but also the greatly-reduced lead time cycle from Selective Laser Sintering(SLS plastic prototyping to metallic parts. The key forming technology of RPC for complex thin-walled metallic parts has been developed for new casting production and Rapid Tooling (RT, and it is possible to rapidly manufacture high-quality and accurate metallic parts by means of RP in foundry industry.

  17. A hierarchical construction scheme for accurate potential energy surface generation: an application to the F+H2 reaction.

    Science.gov (United States)

    Fu, Bina; Xu, Xin; Zhang, Dong H

    2008-07-07

    We present a hierarchical construction scheme for accurate ab initio potential energy surface generation. The scheme is based on the observation that when molecular configuration changes, the variation in the potential energy difference between different ab initio methods is much smaller than the variation for potential energy itself. This means that it is easier to numerically represent energy difference to achieve a desired accuracy. Because the computational cost for ab initio calculations increases very rapidly with the accuracy, one can gain substantial saving in computational time by constructing a high accurate potential energy surface as a sum of a low accurate surface based on extensive ab initio data points and an energy difference surface for high and low accuracy ab initio methods based on much fewer data points. The new scheme was applied to construct an accurate ground potential energy surface for the FH(2) system using the coupled-cluster method and a very large basis set. The constructed potential energy surface is found to be more accurate on describing the resonance states in the FH(2) and FHD systems than the existing surfaces.

  18. Rapid prototyping in medical sciences

    Directory of Open Access Journals (Sweden)

    Ákos Márk Horváth

    2015-09-01

    Full Text Available Even if it sound a bit incredible rapid prototyping (RPT as production method has been used for decades in other professions. Nevertheless medical science just started discover the possibilities of this technology and use the offered benefits of 3D printing. In this paper authors have investigated the pharmaceutical usage of rapid prototyping.

  19. Treatment Integrity Assessment of a Daily Report Card Intervention: A Preliminary Evaluation of Two Methods and Frequencies

    Science.gov (United States)

    Sanetti, Lisa M. Hagermoser; Chafouleas, Sandra M.; O'Keeffe, Breda V.; Kilgus, Stephen P.

    2013-01-01

    Although intuitively appealing, teacher self-report of treatment integrity is not currently recommended as a method for collecting treatment integrity data. Education researchers have not, however, evaluated features of a treatment integrity self-reporting system that may facilitate accurate self-report. In this preliminary investigation, four…

  20. DNA barcode data accurately assign higher spider taxa

    Directory of Open Access Journals (Sweden)

    Jonathan A. Coddington

    2016-07-01

    Full Text Available The use of unique DNA sequences as a method for taxonomic identification is no longer fundamentally controversial, even though debate continues on the best markers, methods, and technology to use. Although both existing databanks such as GenBank and BOLD, as well as reference taxonomies, are imperfect, in best case scenarios “barcodes” (whether single or multiple, organelle or nuclear, loci clearly are an increasingly fast and inexpensive method of identification, especially as compared to manual identification of unknowns by increasingly rare expert taxonomists. Because most species on Earth are undescribed, a complete reference database at the species level is impractical in the near term. The question therefore arises whether unidentified species can, using DNA barcodes, be accurately assigned to more inclusive groups such as genera and families—taxonomic ranks of putatively monophyletic groups for which the global inventory is more complete and stable. We used a carefully chosen test library of CO1 sequences from 49 families, 313 genera, and 816 species of spiders to assess the accuracy of genus and family-level assignment. We used BLAST queries of each sequence against the entire library and got the top ten hits. The percent sequence identity was reported from these hits (PIdent, range 75–100%. Accurate assignment of higher taxa (PIdent above which errors totaled less than 5% occurred for genera at PIdent values >95 and families at PIdent values ≥ 91, suggesting these as heuristic thresholds for accurate generic and familial identifications in spiders. Accuracy of identification increases with numbers of species/genus and genera/family in the library; above five genera per family and fifteen species per genus all higher taxon assignments were correct. We propose that using percent sequence identity between conventional barcode sequences may be a feasible and reasonably accurate method to identify animals to family/genus. However

  1. Rapid magnetic cell delivery for large tubular bioengineered constructs.

    Science.gov (United States)

    Gonzalez-Molina, J; Riegler, J; Southern, P; Ortega, D; Frangos, C C; Angelopoulos, Y; Husain, S; Lythgoe, M F; Pankhurst, Q A; Day, R M

    2012-11-07

    Delivery of cells into tubular tissue constructs with large diameters poses significant spatial and temporal challenges. This study describes preliminary findings for a novel process for rapid and uniform seeding of cells onto the luminal surface of large tubular constructs. Fibroblasts, tagged with superparamagnetic iron oxide nanoparticles (SPION), were directed onto the luminal surface of tubular constructs by a magnetic field generated by a k4-type Halbach cylinder device. The spatial distribution of attached cells, as measured by the mean number of cells, was compared with a conventional, dynamic, rotational cell-delivery technique. Cell loading onto the constructs was measured by microscopy and magnetic resonance imaging. The different seeding techniques employed had a significant effect on the spatial distribution of the cells (p same construct was significantly different for the dynamic rotation technique (p delivery techniques and is amenable to a variety of tubular organs where rapid loading and uniform distribution of cells for therapeutic applications are required.

  2. Intraperitoneal Glucose Sensing is Sometimes Surprisingly Rapid

    Directory of Open Access Journals (Sweden)

    Anders Lyngvi Fougner

    2016-04-01

    Full Text Available Rapid, accurate and robust glucose measurements are needed to make a safe artificial pancreas for the treatment of diabetes mellitus type 1 and 2. The present gold standard of continuous glucose sensing, subcutaneous (SC glucose sensing, has been claimed to have slow response and poor robustness towards local tissue changes such as mechanical pressure, temperature changes, etc. The present study aimed at quantifying glucose dynamics from central circulation to intraperitoneal (IP sensor sites, as an alternative to the SC location. Intraarterial (IA and IP sensors were tested in three anaesthetized non-diabetic pigs during experiments with intravenous infusion of glucose boluses, enforcing rapid glucose level excursions in the range 70--360 mg/dL (approximately 3.8--20 mmol/L. Optical interferometric sensors were used for IA and IP measurements. A first-order dynamic model with time delay was fitted to the data after compensating for sensor dynamics. Additionally, off-the-shelf Medtronic Enlite sensors were used for illustration of SC glucose sensing. The time delay in glucose excursions from central circulation (IA to IP sensor location was found to be in the range 0--26 s (median: 8.5 s, mean: 9.7 s, SD 9.5 s, and the time constant was found to be 0.5--10.2 min (median: 4.8 min, mean: 4.7 min, SD 2.9 min. IP glucose sensing sites have a substantially faster and more distinctive response than SC sites when sensor dynamics is ignored, and the peritoneal fluid reacts even faster to changes in intravascular glucose levels than reported in previous animal studies. This study may provide a benchmark for future, rapid IP glucose sensors.

  3. Fast and accurate generation method of PSF-based system matrix for PET reconstruction

    CERN Document Server

    Sun, Xiao-Li; Yun, Ming-Kai; Li, Dao-Wu; Gao, Juan; Li, Mo-Han; Chai, Pei; Tang, Hao-Hui; Zhang, Zhi-Ming; Wei, Long

    2016-01-01

    Positional single photon incidence response (P-SPIR) theory is researched in this paper to generate more accurate PSF-contained system matrix simply and quickly. The method has been proved highly effective to improve the spatial resolution by applying to the Eplus-260 primate PET designed by the Institute of High Energy Physics of the Chinese Academy of Sciences(IHEP). Simultaneously, to meet the clinical needs, GPU acceleration is put to use. Basically, P-SPIR theory takes both incidence angle and incidence position by crystal subdivision instead of only incidence angle into consideration based on Geant4 Application for Emission Tomography (GATE). The simulation conforms to the actual response distribution and can be completed rapidly within less than 1s. Furthermore,two-block penetration and normalization of the response probability are raised to fit the reality. With PSF obtained, the homogenization model is analyzed to calculate the spread distribution of bins within a few minutes for system matrix genera...

  4. ROM Plus(®): accurate point-of-care detection of ruptured fetal membranes.

    Science.gov (United States)

    McQuivey, Ross W; Block, Jon E

    2016-01-01

    Accurate and timely diagnosis of rupture of fetal membranes is imperative to inform and guide gestational age-specific interventions to optimize perinatal outcomes and reduce the risk of serious complications, including preterm delivery and infections. The ROM Plus is a rapid, point-of-care, qualitative immunochromatographic diagnostic test that uses a unique monoclonal/polyclonal antibody approach to detect two different proteins found in amniotic fluid at high concentrations: alpha-fetoprotein and insulin-like growth factor binding protein-1. Clinical study results have uniformly demonstrated high diagnostic accuracy and performance characteristics with this point-of-care test that exceeds conventional clinical testing with external laboratory evaluation. The description, indications for use, procedural steps, and laboratory and clinical characterization of this assay are presented in this article.

  5. Accurate Identification of Fatty Liver Disease in Data Warehouse Utilizing Natural Language Processing.

    Science.gov (United States)

    Redman, Joseph S; Natarajan, Yamini; Hou, Jason K; Wang, Jingqi; Hanif, Muzammil; Feng, Hua; Kramer, Jennifer R; Desiderio, Roxanne; Xu, Hua; El-Serag, Hashem B; Kanwal, Fasiha

    2017-10-01

    Natural language processing is a powerful technique of machine learning capable of maximizing data extraction from complex electronic medical records. We utilized this technique to develop algorithms capable of "reading" full-text radiology reports to accurately identify the presence of fatty liver disease. Abdominal ultrasound, computerized tomography, and magnetic resonance imaging reports were retrieved from the Veterans Affairs Corporate Data Warehouse from a random national sample of 652 patients. Radiographic fatty liver disease was determined by manual review by two physicians and verified with an expert radiologist. A split validation method was utilized for algorithm development. For all three imaging modalities, the algorithms could identify fatty liver disease with >90% recall and precision, with F-measures >90%. These algorithms could be used to rapidly screen patient records to establish a large cohort to facilitate epidemiological and clinical studies and examine the clinic course and outcomes of patients with radiographic hepatic steatosis.

  6. Compact model of power MOSFET with temperature dependent Cauer RC network for more accurate thermal simulations

    Science.gov (United States)

    Marek, Juraj; Chvála, Aleš; Donoval, Daniel; Príbytný, Patrik; Molnár, Marián; Mikolášek, Miroslav

    2014-04-01

    A new, more accurate SPICE-like model of a power MOSFET containing a temperature dependent thermal network is described. The designed electro-thermal MOSFET model consists of several parts which represent different transistor behavior under different conditions such as reverse bias, avalanche breakdown and others. The designed model is able to simulate destruction of the device as thermal runaway and/or overcurrent destruction during the switching process of a wide variety of inductive loads. Modified thermal equivalent circuit diagrams were designed taking into account temperature dependence of thermal resistivity. The potential and limitations of the new models are presented and analyzed. The new model is compared with the standard and empirical models and brings a higher accuracy for rapid heating pulses. An unclamped inductive switching (UIS) test as a stressful condition was used to verify the proper behavior of the designed MOSFET model.

  7. Multimodal Spatial Calibration for Accurately Registering EEG Sensor Positions

    Directory of Open Access Journals (Sweden)

    Jianhua Zhang

    2014-01-01

    Full Text Available This paper proposes a fast and accurate calibration method to calibrate multiple multimodal sensors using a novel photogrammetry system for fast localization of EEG sensors. The EEG sensors are placed on human head and multimodal sensors are installed around the head to simultaneously obtain all EEG sensor positions. A multiple views’ calibration process is implemented to obtain the transformations of multiple views. We first develop an efficient local repair algorithm to improve the depth map, and then a special calibration body is designed. Based on them, accurate and robust calibration results can be achieved. We evaluate the proposed method by corners of a chessboard calibration plate. Experimental results demonstrate that the proposed method can achieve good performance, which can be further applied to EEG source localization applications on human brain.

  8. Note-accurate audio segmentation based on MPEG-7

    Science.gov (United States)

    Wellhausen, Jens

    2003-12-01

    Segmenting audio data into the smallest musical components is the basis for many further meta data extraction algorithms. For example, an automatic music transcription system needs to know where the exact boundaries of each tone are. In this paper a note accurate audio segmentation algorithm based on MPEG-7 low level descriptors is introduced. For a reliable detection of different notes, both features in the time and the frequency domain are used. Because of this, polyphonic instrument mixes and even melodies characterized by human voices can be examined with this alogrithm. For testing and verification of the note accurate segmentation, a simple music transcription system was implemented. The dominant frequency within each segment is used to build a MIDI file representing the processed audio data.

  9. The FLUKA code: An accurate simulation tool for particle therapy

    CERN Document Server

    Battistoni, Giuseppe; Böhlen, Till T; Cerutti, Francesco; Chin, Mary Pik Wai; Dos Santos Augusto, Ricardo M; Ferrari, Alfredo; Garcia Ortega, Pablo; Kozlowska, Wioletta S; Magro, Giuseppe; Mairani, Andrea; Parodi, Katia; Sala, Paola R; Schoofs, Philippe; Tessonnier, Thomas; Vlachoudis, Vasilis

    2016-01-01

    Monte Carlo (MC) codes are increasingly spreading in the hadrontherapy community due to their detailed description of radiation transport and interaction with matter. The suitability of a MC code for application to hadrontherapy demands accurate and reliable physical models capable of handling all components of the expected radiation field. This becomes extremely important for correctly performing not only physical but also biologically-based dose calculations, especially in cases where ions heavier than protons are involved. In addition, accurate prediction of emerging secondary radiation is of utmost importance in innovative areas of research aiming at in-vivo treatment verification. This contribution will address the recent developments of the FLUKA MC code and its practical applications in this field. Refinements of the FLUKA nuclear models in the therapeutic energy interval lead to an improved description of the mixed radiation field as shown in the presented benchmarks against experimental data with bot...

  10. Simple and High-Accurate Schemes for Hyperbolic Conservation Laws

    Directory of Open Access Journals (Sweden)

    Renzhong Feng

    2014-01-01

    Full Text Available The paper constructs a class of simple high-accurate schemes (SHA schemes with third order approximation accuracy in both space and time to solve linear hyperbolic equations, using linear data reconstruction and Lax-Wendroff scheme. The schemes can be made even fourth order accurate with special choice of parameter. In order to avoid spurious oscillations in the vicinity of strong gradients, we make the SHA schemes total variation diminishing ones (TVD schemes for short by setting flux limiter in their numerical fluxes and then extend these schemes to solve nonlinear Burgers’ equation and Euler equations. The numerical examples show that these schemes give high order of accuracy and high resolution results. The advantages of these schemes are their simplicity and high order of accuracy.

  11. A Highly Accurate Approach for Aeroelastic System with Hysteresis Nonlinearity

    Directory of Open Access Journals (Sweden)

    C. C. Cui

    2017-01-01

    Full Text Available We propose an accurate approach, based on the precise integration method, to solve the aeroelastic system of an airfoil with a pitch hysteresis. A major procedure for achieving high precision is to design a predictor-corrector algorithm. This algorithm enables accurate determination of switching points resulting from the hysteresis. Numerical examples show that the results obtained by the presented method are in excellent agreement with exact solutions. In addition, the high accuracy can be maintained as the time step increases in a reasonable range. It is also found that the Runge-Kutta method may sometimes provide quite different and even fallacious results, though the step length is much less than that adopted in the presented method. With such high computational accuracy, the presented method could be applicable in dynamical systems with hysteresis nonlinearities.

  12. Morphologically accurate reduced order modeling of spiking neurons.

    Science.gov (United States)

    Kellems, Anthony R; Chaturantabut, Saifon; Sorensen, Danny C; Cox, Steven J

    2010-06-01

    Accurately simulating neurons with realistic morphological structure and synaptic inputs requires the solution of large systems of nonlinear ordinary differential equations. We apply model reduction techniques to recover the complete nonlinear voltage dynamics of a neuron using a system of much lower dimension. Using a proper orthogonal decomposition, we build a reduced-order system from salient snapshots of the full system output, thus reducing the number of state variables. A discrete empirical interpolation method is then used to reduce the complexity of the nonlinear term to be proportional to the number of reduced variables. Together these two techniques allow for up to two orders of magnitude dimension reduction without sacrificing the spatially-distributed input structure, with an associated order of magnitude speed-up in simulation time. We demonstrate that both nonlinear spiking behavior and subthreshold response of realistic cells are accurately captured by these low-dimensional models.

  13. FIXED-WING MICRO AERIAL VEHICLE FOR ACCURATE CORRIDOR MAPPING

    Directory of Open Access Journals (Sweden)

    M. Rehak

    2015-08-01

    Full Text Available In this study we present a Micro Aerial Vehicle (MAV equipped with precise position and attitude sensors that together with a pre-calibrated camera enables accurate corridor mapping. The design of the platform is based on widely available model components to which we integrate an open-source autopilot, customized mass-market camera and navigation sensors. We adapt the concepts of system calibration from larger mapping platforms to MAV and evaluate them practically for their achievable accuracy. We present case studies for accurate mapping without ground control points: first for a block configuration, later for a narrow corridor. We evaluate the mapping accuracy with respect to checkpoints and digital terrain model. We show that while it is possible to achieve pixel (3-5 cm mapping accuracy in both cases, precise aerial position control is sufficient for block configuration, the precise position and attitude control is required for corridor mapping.

  14. Accurate automated detection of autism related corpus callosum abnormalities.

    Science.gov (United States)

    El-Baz, Ayman; Elnakib, Ahmed; Casanova, Manuel F; Gimel'farb, Georgy; Switala, Andrew E; Jordan, Desha; Rainey, Sabrina

    2011-10-01

    The importance of accurate early diagnostics of autism that severely affects personal behavior and communication skills cannot be overstated. Neuropathological studies have revealed an abnormal anatomy of the Corpus Callosum (CC) in autistic brains. We propose a new approach to quantitative analysis of three-dimensional (3D) magnetic resonance images (MRI) of the brain that ensures a more accurate quantification of anatomical differences between the CC of autistic and normal subjects. It consists of three main processing steps: (i) segmenting the CC from a given 3D MRI using the learned CC shape and visual appearance; (ii) extracting a centerline of the CC; and (iii) cylindrical mapping of the CC surface for its comparative analysis. Our experiments revealed significant differences (at the 95% confidence level) between 17 normal and 17 autistic subjects in four anatomical divisions, i.e. splenium, rostrum, genu and body of their CCs.

  15. Accurate identification of fear facial expressions predicts prosocial behavior.

    Science.gov (United States)

    Marsh, Abigail A; Kozak, Megan N; Ambady, Nalini

    2007-05-01

    The fear facial expression is a distress cue that is associated with the provision of help and prosocial behavior. Prior psychiatric studies have found deficits in the recognition of this expression by individuals with antisocial tendencies. However, no prior study has shown accuracy for recognition of fear to predict actual prosocial or antisocial behavior in an experimental setting. In 3 studies, the authors tested the prediction that individuals who recognize fear more accurately will behave more prosocially. In Study 1, participants who identified fear more accurately also donated more money and time to a victim in a classic altruism paradigm. In Studies 2 and 3, participants' ability to identify the fear expression predicted prosocial behavior in a novel task designed to control for confounding variables. In Study 3, accuracy for recognizing fear proved a better predictor of prosocial behavior than gender, mood, or scores on an empathy scale.

  16. Groundtruth approach to accurate quantitation of fluorescence microarrays

    Energy Technology Data Exchange (ETDEWEB)

    Mascio-Kegelmeyer, L; Tomascik-Cheeseman, L; Burnett, M S; van Hummelen, P; Wyrobek, A J

    2000-12-01

    To more accurately measure fluorescent signals from microarrays, we calibrated our acquisition and analysis systems by using groundtruth samples comprised of known quantities of red and green gene-specific DNA probes hybridized to cDNA targets. We imaged the slides with a full-field, white light CCD imager and analyzed them with our custom analysis software. Here we compare, for multiple genes, results obtained with and without preprocessing (alignment, color crosstalk compensation, dark field subtraction, and integration time). We also evaluate the accuracy of various image processing and analysis techniques (background subtraction, segmentation, quantitation and normalization). This methodology calibrates and validates our system for accurate quantitative measurement of microarrays. Specifically, we show that preprocessing the images produces results significantly closer to the known ground-truth for these samples.

  17. Fixed-Wing Micro Aerial Vehicle for Accurate Corridor Mapping

    Science.gov (United States)

    Rehak, M.; Skaloud, J.

    2015-08-01

    In this study we present a Micro Aerial Vehicle (MAV) equipped with precise position and attitude sensors that together with a pre-calibrated camera enables accurate corridor mapping. The design of the platform is based on widely available model components to which we integrate an open-source autopilot, customized mass-market camera and navigation sensors. We adapt the concepts of system calibration from larger mapping platforms to MAV and evaluate them practically for their achievable accuracy. We present case studies for accurate mapping without ground control points: first for a block configuration, later for a narrow corridor. We evaluate the mapping accuracy with respect to checkpoints and digital terrain model. We show that while it is possible to achieve pixel (3-5 cm) mapping accuracy in both cases, precise aerial position control is sufficient for block configuration, the precise position and attitude control is required for corridor mapping.

  18. Signal self-enhancement by coordinated assembly of gold nanoparticles enables accurate one-step-immunoassays.

    Science.gov (United States)

    Kwon, J-H; Kim, H-T; Lee, J-H; Kim, R; Heo, M; Shin, J; Lee, H-Y; Cha, Y J; Lee, J

    2017-11-02

    Current immunoassays are in general performed through time-consuming multi-step procedures that depend on the use of premade signal-producing reporters and often cause assay inaccuracy. Here we report an advanced immunoassay technology that resolves the delayed, complex, and inaccurate assay problems of conventional immunoassays. We have developed an accurate, rapid, simple, and label-free one-step-immunoassay based on the self-enhancement of sensitive immunoassay signals in an assay solution. The nano-scale protein particles (hepatitis B virus capsid and human ferritin heavy chain particles) were genetically engineered to present many well-oriented antibody (or antigen) probes and multi-copies of poly-histidine peptides on their surface, resulting in the construction of 3-dimensional (3D) bioprobes that chemisorb gold ions via coordination bonding and sensitively detect both antigen and antibody analytes. Systematic numerical and experimental analyses show that the signal self-enhancement happens through two coupled reactions under reducing conditions: (1) 3D bioprobe-based sensitive immuno-detection of analytes and (2) coordinated assembly of free and chemisorbed gold nanoparticles around the 3D bioprobe-analyte-associated complexes, which is followed by the quick generation of apparent optical signals. This advanced one-step-immunoassay was successfully applied to diagnostic assays requiring high accuracy and/or speed, i.e. diagnosis of acute myocardial infarction and hepatitis C through detecting a cardiac protein (troponin I) and anti-hepatitis C virus antibodies in patient sera, indicating that it is applicable to the accurate and rapid detection of both antigen and antibody markers of a wide range of diseases.

  19. A More Accurate Model for Finding Tutorial Segments Explaining APIs

    OpenAIRE

    Jiang, He; Zhang, Jingxuan; Li, Xiaochen; Ren, Zhilei; Lo, David

    2017-01-01

    Developers prefer to utilize third-party libraries when they implement some functionalities and Application Programming Interfaces (APIs) are frequently used by them. Facing an unfamiliar API, developers tend to consult tutorials as learning resources. Unfortunately, the segments explaining a specific API scatter across tutorials. Hence, it remains a challenging issue to find the relevant segments. In this study, we propose a more accurate model to find the exact tutorial fragments explaining...

  20. An accurate SPICE-compatible circuit model for power FLYMOSFETs

    Science.gov (United States)

    Galadi, A.; Morancho, F.; Benhida, K.; Hassani, M. M.

    2007-09-01

    In this paper, a new SPICE-compatible circuit model for low voltage, low on-resistance power FLYMOSFETs is presented for the first time. In this new structure, the improvement of the on-resistance has been obtained by inserting floating islands in the lowly doped layer. Our modelling is based on device physics, analytical study and on experimental characterization. The inter-electrode capacitances are modelled accurately as nonlinear functions, and good agreement between simulation and measurements is found.

  1. Hybrid Predictive Models for Accurate Forecasting in PV Systems

    Directory of Open Access Journals (Sweden)

    Marco Mussetta

    2013-04-01

    Full Text Available The accurate forecasting of energy production from renewable sources represents an important topic also looking at different national authorities that are starting to stimulate a greater responsibility towards plants using non-programmable renewables. In this paper the authors use advanced hybrid evolutionary techniques of computational intelligence applied to photovoltaic systems forecasting, analyzing the predictions obtained by comparing different definitions of the forecasting error.

  2. Accurate Modeling of Buck Converters with Magnetic-Core Inductors

    DEFF Research Database (Denmark)

    Astorino, Antonio; Antonini, Giulio; Swaminathan, Madhavan

    2015-01-01

    In this paper, a modeling approach for buck converters with magnetic-core inductors is presented. Due to the high nonlinearity of magnetic materials, the frequency domain analysis of such circuits is not suitable for an accurate description of their behaviour. Hence, in this work, a timedomain mo...... hysteretic behavior to be thoroughly taken into account....

  3. Fast and Accurate Bilateral Filtering using Gauss-Polynomial Decomposition

    OpenAIRE

    Chaudhury, Kunal N.

    2015-01-01

    The bilateral filter is a versatile non-linear filter that has found diverse applications in image processing, computer vision, computer graphics, and computational photography. A widely-used form of the filter is the Gaussian bilateral filter in which both the spatial and range kernels are Gaussian. A direct implementation of this filter requires $O(\\sigma^2)$ operations per pixel, where $\\sigma$ is the standard deviation of the spatial Gaussian. In this paper, we propose an accurate approxi...

  4. Developing a second generation Laue lens prototype: high-reflectivity crystals and accurate assembly

    Science.gov (United States)

    Barrière, Nicolas M.; Tomsick, John A.; Boggs, Steven E.; Lowell, Alexander; von Ballmoos, Peter

    2011-09-01

    Laue lenses are an emerging technology that will enhance gamma-ray telescope sensitivity by one to two orders of magnitude in selected energy bands of the ~100 keV to ~1.5 MeV range. This optic would be particularly well adapted to the observation of faint gamma ray lines, as required for the study of Supernovae and Galactic positron annihilation. It could also prove very useful for the study of hard X-ray tails from a variety of compact objects, especially making a difference by providing sufficient sensitivity for polarization to be measured by the focal plane detector. Our group has been addressing the two key issues relevant to improve performance with respect to the first generation of Laue lens prototypes: obtaining large numbers of efficient crystals and developing a method to fix them with accurate orientation and dense packing factor onto a substrate. We present preliminary results of an on-going study aiming to enable a large number of crystals suitable for diffraction at energies above 500 keV. In addition, we show the first results of the Laue lens prototype assembled using our beamline at SSL/UC Berkeley, which demonstrates our ability to orient and glue crystals with accuracy of a few arcsec, as required for an efficient Laue lens telescope.

  5. Can cancer researchers accurately judge whether preclinical reports will reproduce?

    Directory of Open Access Journals (Sweden)

    Daniel Benjamin

    2017-06-01

    Full Text Available There is vigorous debate about the reproducibility of research findings in cancer biology. Whether scientists can accurately assess which experiments will reproduce original findings is important to determining the pace at which science self-corrects. We collected forecasts from basic and preclinical cancer researchers on the first 6 replication studies conducted by the Reproducibility Project: Cancer Biology (RP:CB to assess the accuracy of expert judgments on specific replication outcomes. On average, researchers forecasted a 75% probability of replicating the statistical significance and a 50% probability of replicating the effect size, yet none of these studies successfully replicated on either criterion (for the 5 studies with results reported. Accuracy was related to expertise: experts with higher h-indices were more accurate, whereas experts with more topic-specific expertise were less accurate. Our findings suggest that experts, especially those with specialized knowledge, were overconfident about the RP:CB replicating individual experiments within published reports; researcher optimism likely reflects a combination of overestimating the validity of original studies and underestimating the difficulties of repeating their methodologies.

  6. An accurate metric for the spacetime around neutron stars

    CERN Document Server

    Pappas, George

    2016-01-01

    The problem of having an accurate description of the spacetime around neutron stars is of great astrophysical interest. For astrophysical applications, one needs to have a metric that captures all the properties of the spacetime around a neutron star. Furthermore, an accurate appropriately parameterised metric, i.e., a metric that is given in terms of parameters that are directly related to the physical structure of the neutron star, could be used to solve the inverse problem, which is to infer the properties of the structure of a neutron star from astrophysical observations. In this work we present such an approximate stationary and axisymmetric metric for the exterior of neutron stars, which is constructed using the Ernst formalism and is parameterised by the relativistic multipole moments of the central object. This metric is given in terms of an expansion on the Weyl-Papapetrou coordinates with the multipole moments as free parameters and is shown to be extremely accurate in capturing the physical propert...

  7. Accurate and Reliable Gait Cycle Detection in Parkinson's Disease.

    Science.gov (United States)

    Hundza, Sandra R; Hook, William R; Harris, Christopher R; Mahajan, Sunny V; Leslie, Paul A; Spani, Carl A; Spalteholz, Leonhard G; Birch, Benjamin J; Commandeur, Drew T; Livingston, Nigel J

    2014-01-01

    There is a growing interest in the use of Inertial Measurement Unit (IMU)-based systems that employ gyroscopes for gait analysis. We describe an improved IMU-based gait analysis processing method that uses gyroscope angular rate reversal to identify the start of each gait cycle during walking. In validation tests with six subjects with Parkinson disease (PD), including those with severe shuffling gait patterns, and seven controls, the probability of True-Positive event detection and False-Positive event detection was 100% and 0%, respectively. Stride time validation tests using high-speed cameras yielded a standard deviation of 6.6 ms for controls and 11.8 ms for those with PD. These data demonstrate that the use of our angular rate reversal algorithm leads to improvements over previous gyroscope-based gait analysis systems. Highly accurate and reliable stride time measurements enabled us to detect subtle changes in stride time variability following a Parkinson's exercise class. We found unacceptable measurement accuracy for stride length when using the Aminian et al gyro-based biomechanical algorithm, with errors as high as 30% in PD subjects. An alternative method, using synchronized infrared timing gates to measure velocity, combined with accurate mean stride time from our angular rate reversal algorithm, more accurately calculates mean stride length.

  8. Rapid detection of genetic modification for GMO monitoring in agriculture

    Directory of Open Access Journals (Sweden)

    Petrović Sofija

    2015-01-01

    Full Text Available Transgenic technology has expanded the ways of new genetic variability creation. Genetically modified organisms (GMOs are organisms which total genome is altered in a way that could not happen in nature. GM crops recorded a steady increase in its share in agricultural production. However, for the most part, GMO in agriculture has been limited to two cultivars - soy and corn, and the two genetic modifications, the total herbicide resistance and pest of the Lepidoptera genus. In order to monitor cultivation and trade of GMOs, tests of different precision are used, qualitatively and/or quantitatively determining the presence of genetic modification. Tests for the rapid determination of the presence of GM are suitable, since they can be implemented quickly and accurately, in terms of declared sensitivity, outside or in the laboratory. The example of the use of rapid tests demonstrates their value in use for rapid and efficient monitoring.

  9. How Rapid is Rapid Prototyping? Analysis of ESPADON Programme Results

    Directory of Open Access Journals (Sweden)

    Ian D. Alston

    2003-05-01

    Full Text Available New methodologies, engineering processes, and support environments are beginning to emerge for embedded signal processing systems. The main objectives are to enable defence industry to field state-of-the-art products in less time and with lower costs, including retrofits and upgrades, based predominately on commercial off the shelf (COTS components and the model-year concept. One of the cornerstones of the new methodologies is the concept of rapid prototyping. This is the ability to rapidly and seamlessly move from functional design to the architectural design to the implementation, through automatic code generation tools, onto real-time COTS test beds. In this paper, we try to quantify the term “rapid” and provide results, the metrics, from two independent benchmarks, a radar and sonar beamforming application subset. The metrics show that the rapid prototyping process may be sixteen times faster than a conventional process.

  10. Accurate Measurement of the in vivo Ammonium Concentration in Saccharomyces cerevisiae

    Directory of Open Access Journals (Sweden)

    Hugo F. Cueto-Rojas

    2016-04-01

    Full Text Available Ammonium (NH4+ is the most common N-source for yeast fermentations, and N-limitation is frequently applied to reduce growth and increase product yields. While there is significant molecular knowledge on NH4+ transport and assimilation, there have been few attempts to measure the in vivo concentration of this metabolite. In this article, we present a sensitive and accurate analytical method to quantify the in vivo intracellular ammonium concentration in Saccharomyces cerevisiae based on standard rapid sampling and metabolomics techniques. The method validation experiments required the development of a proper sample processing protocol to minimize ammonium production/consumption during biomass extraction by assessing the impact of amino acid degradation—an element that is often overlooked. The resulting cold chloroform metabolite extraction method, together with quantification using ultra high performance liquid chromatography-isotope dilution mass spectrometry (UHPLC-IDMS, was not only more sensitive than most of the existing methods but also more accurate than methods that use electrodes, enzymatic reactions, or boiling water or boiling ethanol biomass extraction because it minimized ammonium consumption/production during sampling processing and interference from other metabolites in the quantification of intracellular ammonium. Finally, our validation experiments showed that other metabolites such as pyruvate or 2-oxoglutarate (αKG need to be extracted with cold chloroform to avoid measurements being biased by the degradation of other metabolites (e.g., amino acids.

  11. Comparison of thermistor linearization techniques for accurate temperature measurement in phase change materials

    Energy Technology Data Exchange (ETDEWEB)

    Stankovic, S B; Kyriacou, P A, E-mail: p.kyriacou@city.ac.uk [School of Engineering and Mathematical Sciences, City University London, Northampton Square, London EC1V 0HB (United Kingdom)

    2011-08-17

    Alternate energy technologies are developing rapidly in the recent years. A significant part of this trend is the development of different phase change materials (PCMs). Proper utilization of PCMs requires accurate thermal characterization. There are several methodologies used in this field. This paper stresses the importance of accurate temperature measurements during the implementation of T-history method. Since the temperature sensor size is also important thermistors have been selected as the sensing modality. Two thermistor linearization techniques, one based on Wheatstone bridge and the other based on simple serial-parallel resistor connection, are compared in terms of achievable temperature accuracy through consideration of both, nonlinearity and self-heating errors. Proper calibration was performed before T-history measurement of RT21 (RUBITHERM (registered) GmbH) PCM. Measurement results suggest that the utilization of serial-parallel resistor connection gives better accuracy (less than {+-}0.1 deg. C) in comparison with the Wheatstone bridge based configuration (up to {+-}1.5 deg. C).

  12. Evaluation of new reference genes in papaya for accurate transcript normalization under different experimental conditions.

    Directory of Open Access Journals (Sweden)

    Xiaoyang Zhu

    Full Text Available Real-time reverse transcription PCR (RT-qPCR is a preferred method for rapid and accurate quantification of gene expression studies. Appropriate application of RT-qPCR requires accurate normalization though the use of reference genes. As no single reference gene is universally suitable for all experiments, thus reference gene(s validation under different experimental conditions is crucial for RT-qPCR analysis. To date, only a few studies on reference genes have been done in other plants but none in papaya. In the present work, we selected 21 candidate reference genes, and evaluated their expression stability in 246 papaya fruit samples using three algorithms, geNorm, NormFinder and RefFinder. The samples consisted of 13 sets collected under different experimental conditions, including various tissues, different storage temperatures, different cultivars, developmental stages, postharvest ripening, modified atmosphere packaging, 1-methylcyclopropene (1-MCP treatment, hot water treatment, biotic stress and hormone treatment. Our results demonstrated that expression stability varied greatly between reference genes and that different suitable reference gene(s or combination of reference genes for normalization should be validated according to the experimental conditions. In general, the internal reference genes EIF (Eukaryotic initiation factor 4A, TBP1 (TATA binding protein 1 and TBP2 (TATA binding protein 2 genes had a good performance under most experimental conditions, whereas the most widely present used reference genes, ACTIN (Actin 2, 18S rRNA (18S ribosomal RNA and GAPDH (Glyceraldehyde-3-phosphate dehydrogenase were not suitable in many experimental conditions. In addition, two commonly used programs, geNorm and Normfinder, were proved sufficient for the validation. This work provides the first systematic analysis for the selection of superior reference genes for accurate transcript normalization in papaya under different experimental

  13. Preliminary

    Directory of Open Access Journals (Sweden)

    Desde el Jardín de Freud

    2017-01-01

    Full Text Available Desde el Jardín de Freud is indexed in the IBN-Publindex (Colciencias in category C, and the following databases and catalogs: EBSCO, ProQuest, Google Scholar, CLASE, Latindex, Dialnet, Rebiun, Doaj, e-revistas and Library Luis Angel Arango virtual.

  14. Preliminaries

    Directory of Open Access Journals (Sweden)

    Desde el jardín de Freud

    2014-10-01

    Full Text Available Desde el Jardín de Freud se encuentra indexada en el IBN-Publindex (Colciencias, en categoría C, y en Latindex. También se encuentra en las siguientes bases de datos y catálogos: ebsco, Dialnet, Rebiun, Doaj y e-Revistas.

  15. Preliminary

    Directory of Open Access Journals (Sweden)

    Abeer M. Ismail

    2016-06-01

    Full Text Available Phytochemical analysis of the methanolic and aqueous extracts of Faidherbia albida legumes indicated the presence of terpenes, cardiac glycosides, monosaccharides and carbohydrates type of compounds in both extracts. While alkaloids and saponins were found in aqueous extract only, flavonoids were found to be absent in both extracts. The aqueous and methanolic extracts exhibited a potent growth stimulation effect. Inhibition of both the rootlet and shoot showed a dose dependent response. Aqueous extract has a greater inhibitory effect on rootlet growth than shoot growth. The methanolic extract has a greater inhibitory effect than the aqueous extract. Both extracts and some fractions were tested against three pathogenic bacterial species; Staphylococcus aureus, Escherichia coli and Shigella dysenteriae, also tested against three pathogenic fungal species; Fusarium oxysporum, Alternaria alternate, and Aspergillus niger. Most of the plant extracts stimulate the studied fungal growth specially the aqueous extract. Meanwhile it shows interesting results by inhibiting the growth of the studied pathogenic bacterial species with most extracts and fractions.

  16. Rapid diagnosis of pyrazinamide-resistant multidrug-resistant tuberculosis using a molecular-based diagnostic algorithm

    NARCIS (Netherlands)

    Simons, S.O.; Laan, T. van der; Mulder, A.; Ingen, J. van; Rigouts, L.; Dekhuijzen, P.N.R.; Boeree, M.J.; Soolingen, D. van

    2014-01-01

    There is an urgent need for rapid and accurate diagnosis of pyrazinamide-resistant multidrug-resistant tuberculosis (MDR-TB). No diagnostic algorithm has been validated in this population. We hypothesized that pncA sequencing added to rpoB mutation analysis can accurately identify patients with

  17. Use of high-resolution accurate mass spectrometry to detect reported and previously unreported cannabinomimetics in "herbal high" products.

    Science.gov (United States)

    Hudson, Simon; Ramsey, John; King, Les; Timbers, Sarah; Maynard, Steve; Dargan, Paul I; Wood, David M

    2010-06-01

    A range of "Herbal High" products were tested for synthetic cannabinoids (cannabinomimetics) to qualitatively determine and compare their individual and relative content. Liquid chromatography-high resolution accurate mass spectrometry was used to rapidly screen samples for a range of cannabinomimetics using mono-isotopic masses derived from the elemental composition of target analytes. A screening database of over 140 compounds was rapidly created. This approach, combined with further tandem mass spectrometric experiments, also facilitated the detection and identification of compounds for which reference materials were not available. Previously reported cannabinomimetics, including JWH-018 and CP47,497 and its homologues, were detected in varying relative proportions along with several tentatively identified unreported cannabinomimetics. In some countries, the decision has been made to include these substances within their drug control legislation, and other countries are considering similar action. The currently applied drug screening techniques are unlikely to be effective in providing scientific evidence to support their identification in seized products. The application of high-resolution accurate mass spectrometry offers a solution. In addition, the technology provides a relatively simple and quick method for screening products, building substance databases, and even identifying novel substances using a combination of accurate mass derived elemental composition and fragment ions combined with fragmentation prediction software.

  18. Preliminary bolted-joint data

    Science.gov (United States)

    Wichorek, G. R.

    1979-01-01

    Bolted-joint strength and failure modes for advanced graphite/polyimide composite laminates at 116K (-250 F), room temperature, and 589K (600 F) were determined to provide preliminary design data. The bolted-joint test setup for the low and elevated temperature tests is described. Test results are reported on a quasi-isotropic laminate of Celion 6000/PMR-15. Single bolt, double lap shear specimens were tested to obtain maximum joint strength and failure mode. The effect of joint geometry and temperature on joint strength and failure mode is presented.

  19. TCA High Lift Preliminary Assessment

    Science.gov (United States)

    Wyatt, G. H.; Polito, R. C.; Yeh, D. T.; Elzey, M. E.; Tran, J. T.; Meredith, Paul T.

    1999-01-01

    This paper presents a TCA (Technology Concept Airplane) High lift Preliminary Assessment. The topics discussed are: 1) Model Description; 2) Data Repeatability; 3) Effect of Inboard L.E. (Leading Edge) Flap Span; 4) Comparison of 14'x22' TCA-1 With NTF (National Transonic Facility) Modified Ref. H; 5) Comparison of 14'x22' and NTF Ref. H Results; 6) Effect of Outboard Sealed Slat on TCA; 7) TCA Full Scale Build-ups; 8) Full Scale L/D Comparisons; 9) TCA Full Scale; and 10) Touchdown Lift Curves. This paper is in viewgraph form.

  20. Preliminary considerations concerning actinide solubilities

    Energy Technology Data Exchange (ETDEWEB)

    Newton, T.W.; Bayhurst, B.P.; Daniels, W.R.; Erdal, B.R.; Ogard, A.E.

    1980-01-01

    Work at the Los Alamos Scientific Laboratory on the fundamental solution chemistry of the actinides has thus far been confined to preliminary considerations of the problems involved in developing an understanding of the precipitation and dissolution behavior of actinide compounds under environmental conditions. Attempts have been made to calculate solubility as a function of Eh and pH using the appropriate thermodynamic data; results have been presented in terms of contour maps showing lines of constant solubility as a function of Eh and pH. Possible methods of control of the redox potential of rock-groundwater systems by the use of Eh buffers (redox couples) is presented.

  1. A Rapid Coliform Detector Project

    Data.gov (United States)

    National Aeronautics and Space Administration — ORBITEC, in collaboration with Lucigen, proposes a rapid genetic detector for spaceflight water systems to enable real-time detection of E-coli with minimal...

  2. Rapid Multiplex Microbial Detector Project

    Data.gov (United States)

    National Aeronautics and Space Administration — ORBITEC, in collaboration with Lucigen, proposes a rapid nucleic acid-based detector for spaceflight water systems to enable simultaneous quantification of multiple...

  3. antibacterial properties and preliminary phytochemical analysis of ...

    African Journals Online (AJOL)

    DR. AMINU

    ISSN 2006 - 6996. ANTIBACTERIAL PROPERTIES AND PRELIMINARY PHYTOCHEMICAL ... MATERIALS AND METHODS. Sources of ... agar diffusion method of Garrod, et al., (1981) and ... positive reference standard to determine the.

  4. Accurate mobile malware detection and classification in the cloud

    OpenAIRE

    Wang, Xiaolei; Yang, Yuexiang; Zeng, Yingzhi

    2015-01-01

    As the dominator of the Smartphone operating system market, consequently android has attracted the attention of s malware authors and researcher alike. The number of types of android malware is increasing rapidly regardless of the considerable number of proposed malware analysis systems. In this paper, by taking advantages of low false-positive rate of misuse detection and the ability of anomaly detection to detect zero-day malware, we propose a novel hybrid detection system based on a new op...

  5. Rapid HIV-1 testing during labor: a multicenter study.

    Science.gov (United States)

    Bulterys, Marc; Jamieson, Denise J; O'Sullivan, Mary Jo; Cohen, Mardge H; Maupin, Robert; Nesheim, Steven; Webber, Mayris P; Van Dyke, Russell; Wiener, Jeffrey; Branson, Bernard M

    2004-07-14

    Timely testing of women in labor with undocumented human immunodeficiency virus (HIV) status could enable immediate provision of antiretroviral prophylaxis. To determine the feasibility and acceptance of rapid HIV testing among women in labor and to assess rapid HIV assay performance. The Mother-Infant Rapid Intervention At Delivery (MIRIAD) study implemented 24-hour counseling and voluntary rapid HIV testing for women in labor at 16 US hospitals from November 16, 2001, through November 15, 2003. A rapid HIV-1 antibody test for whole blood was used. Acceptance of HIV testing; sensitivity, specificity, and predictive value of the rapid test; time from blood collection to patient notification of results. There were 91,707 visits to the labor and delivery units in the study, 7381 of which were by eligible women without documentation of HIV testing. Of these, 5744 (78%) women were approached for rapid HIV testing and 4849 (84%) consented. HIV-1 test results were positive for 34 women (prevalence = 7/1000). Sensitivity and specificity of the rapid test were 100% and 99.9%, respectively; positive predictive value was 90% compared with 76% for enzyme immunoassay (EIA). Factors independently associated with higher test acceptance included younger age, being black or Hispanic, gestational age less than 32 weeks, and having had no prenatal care. Lower acceptance was associated with being admitted between 4 pm and midnight, particularly on Friday nights, but this may be explained in part by fewer available personnel. Median time from blood collection to patient notification of result was 66 minutes (interquartile range, 45-120 minutes), compared with 28 hours for EIA (PHIV testing is feasible and delivers accurate and timely test results for women in labor. It provides HIV-positive women prompt access to intrapartum and neonatal antiretroviral prophylaxis, proven to reduce perinatal HIV transmission, and may be particularly applicable to higher-risk populations.

  6. An accurate metric for the spacetime around rotating neutron stars

    Science.gov (United States)

    Pappas, George

    2017-04-01

    The problem of having an accurate description of the spacetime around rotating neutron stars is of great astrophysical interest. For astrophysical applications, one needs to have a metric that captures all the properties of the spacetime around a rotating neutron star. Furthermore, an accurate appropriately parametrized metric, I.e. a metric that is given in terms of parameters that are directly related to the physical structure of the neutron star, could be used to solve the inverse problem, which is to infer the properties of the structure of a neutron star from astrophysical observations. In this work, we present such an approximate stationary and axisymmetric metric for the exterior of rotating neutron stars, which is constructed using the Ernst formalism and is parametrized by the relativistic multipole moments of the central object. This metric is given in terms of an expansion on the Weyl-Papapetrou coordinates with the multipole moments as free parameters and is shown to be extremely accurate in capturing the physical properties of a neutron star spacetime as they are calculated numerically in general relativity. Because the metric is given in terms of an expansion, the expressions are much simpler and easier to implement, in contrast to previous approaches. For the parametrization of the metric in general relativity, the recently discovered universal 3-hair relations are used to produce a three-parameter metric. Finally, a straightforward extension of this metric is given for scalar-tensor theories with a massless scalar field, which also admit a formulation in terms of an Ernst potential.

  7. Accurate LAI retrieval method based on PROBA/CHRIS data

    Directory of Open Access Journals (Sweden)

    W. J. Fan

    2010-08-01

    Full Text Available Leaf area index (LAI is one of the key structural variables in terrestrial vegetation ecosystems. Remote sensing offers an opportunity to accurately derive LAI at regional scales. The anisotropy of canopy reflectance, variations in background characteristics, and variability in atmospheric conditions constitute three factors that can strongly constrain the accuracy of retrieved LAI. Based on a hybrid canopy reflectance model, a new hyperspectral directional second derivative method (DSD is proposed in this paper. This method can estimate LAI accurately through analyzing the canopy anisotropy. The effect of the background can also be effectively removed. With the aid of a widely-accepted atmospheric model, the influence of atmospheric conditions can be minimized as well. Thus the inversion precision and the dynamic range can be markedly improved, which has been proved by numerical simulations. As the derivative method is very sensitive to random noise, we put forward an innovative filtering approach, by which the data can be de-noised in spectral and spatial dimensions synchronously. It shows that the filtering method can remove random noise effectively; therefore, the method can be applied to hyperspectral images. The study region was situated in Zhangye, Gansu Province, China; hyperspectral and multi-angular images of the study region were acquired via the Compact High-Resolution Imaging Spectrometer/Project for On-Board Autonomy (CHRIS/PROBA, on 4 June 2008. After the pre-processing procedures, the DSD method was applied, and the retrieved LAI was validated by ground reference data at 11 sites. Results show that the new LAI inversion method is accurate and effective with the aid of the innovative filtering method.

  8. Rapid Detection of Bacterial Antibiotic Resistance: Preliminary Evaluation of PCR Assays Targeting Tetracycline Resistance Genes

    Science.gov (United States)

    2007-08-01

    Doxycycline Brucella spp. Brucellosis Aminoglycosides, Doxycycline, Tetracyclines Burkholderia mallei Glanders Penicillins, Tetracyclines...antibiotics: Mode of action, applications, molecular biology, and epidemiology of bacterial resistance. Molecular Biology Reviews 65: 232-260 5

  9. The protocol and preliminary baseline survey results of the thyroid ultrasound examination in Fukushima [Rapid Communication].

    Science.gov (United States)

    Suzuki, Shinichi; Yamashita, Shunichi; Fukushima, Toshihiko; Nakano, Keiichi; Midorikawa, Sanae; Ohtsuru, Akira; Yasumura, Seiji; Hosoya, Mitsunori; Kamiya, Kenji; Shimura, Hiroki; Suzuki, Satoru; Nakamura, Izumi; Abe, Masafumi

    2016-01-01

    After the Fukushima nuclear power plant accident on March 11, 2011, the public of Japan became particularly concerned about the possibility of an increased risk of childhood thyroid cancer, similar to what was observed after the Chernobyl's accident. Due to serious public health perception, there was an urgency to evaluate the baseline levels of childhood thyroid status in Fukushima prefecture. Therefore we have commenced a thyroid ultrasound examination (TUE) survey of the approximately 360,000 pediatric inhabitants (0 to 18 years of age) who lived in Fukushima at the time of the accident in October 2011. The subjects were divided into three categories according to the standardized diagnostic criteria of ultrasound findings. Category A contained the subjects whose TUE findings were intact or benign. Category B were recommended a confirmatory TUE. Category C was recommended an immediate confirmatory TUE. The survey of 40,302 subjects in the first year was completed in March, 2013. There were 40,097 (99.5%), 205 (0.50%) and 0 subjects in categories A, B and C, respectively. Of the 82 category B subjects who underwent fine needle aspiration cytology (FNAC), 12 were diagnosed with a malignant tumor or were suspected to have malignancy. The 12 subjects received thyroid surgery and 11 thyroid cancers and one benign nodule were confirmed histologically after surgery. This is the first large-scaled TUE survey to employ sophisticated ultrasound screening and aim to evaluate the baseline frequency of childhood thyroid nodules and cysts. The results will become the golden standard of future comparative TUE in Fukushima, Japan.

  10. The "RAPID" Cognitive-Behavioral Therapy Program for Inattentive Children: Preliminary Findings

    Science.gov (United States)

    Young, Susan

    2013-01-01

    Objective: The objectives of the current study were to ascertain feasibility and acceptability of directly delivering a cognitive-behavioral therapy (CBT) group intervention for inattentive children in a school setting, to examine the reliability of the RATE-C Questionnaires that accompany the program, and to determine whether they can be used to…

  11. New method for rapid Susceptibility Testing on blood culture with HB&L system: preliminary data

    Directory of Open Access Journals (Sweden)

    Vincenzo Rondinelli

    2010-12-01

    Full Text Available Blood culture, although represents the gold standard in detecting the ethiological agent of sepsis, is rather rarely required in relation to the real diagnostic importance. The result of this test depends in fact on many factors (sample volume, time of collection, accuracy, antibiotic therapy, contamination, number of drawings, drawing site, interpretation difficulties, etc. that are often considered by many clinicians so limited as to doubt about their actual value. The disadvantages are therefore represented by the lack of standardization but also by the low sensitivity and above all by the technical times too long for the clinical needs. Blood culture begins with the drawing of samples from the “septic” patient followed incubation of the bottles in automatic thermostated systems. In case of positive result (36 hours, the culture is Gram stained and streaked on solid media in order to obtain isolated colonies for the identification and the susceptibility testing (48 hours from positive result. The long time required for pathogen identification and susceptibility testing involves empirical broad spectrum antibiotic therapy that can promote the increase of bacterial resistance but also patient management costs. A clinically useful report should be available on short notice in order to guide the clinician to choose the most appropriate antibiotic. The microbiologist has therefore the hard work of reviewing the organization and the management of the procedures.We have therefore started to consider the possibility of treating the blood as an biological liquid in order to quickly determine the susceptibility of bacteria to antibiotics.

  12. Preliminary feasibility studies in times of rapid cost escalation. [Oil shale and tar sand industries

    Energy Technology Data Exchange (ETDEWEB)

    Oliver, E.D.; Moll, A.J.

    1976-01-01

    Not the least of the problems delaying the development and commercialization of synthetic fuel processes has been the extraordinary escalation of cost estimates by factors of up to ten in the past eight years. This study identifies and analyzes some of the most important contributing factors that have converged in the last few years. These factors include overoptimism and ill-defined project scope in the early stages, tightening environmental controls, difficulties in obtaining raw materials and fuels, general inflationary trends, ''hyperinflation'' of the costs of critical equipment, local labor shortages, and increased times required for procurement and construction. Cost increases have been particularly dramatic for ''offsites,'' liberally defined as nonprocess related parts of projects. Case histories of oil shale and tar sand developments are analyzed. Learning curves of costs during development and commercial use are studied. The analysis suggests that the worst of the extraordinary increases (above general inflationary trends) are probably over. Criteria to judge the state of development of processes are given, and some procedures to avoid future pitfalls are suggested.

  13. Non-invasive method for rapid bedside estimation of inotropy: theory and preliminary clinical validation.

    Science.gov (United States)

    Smith, B E; Madigan, V M

    2013-10-01

    There are numerous techniques which attempt to quantify inotropy (or myocardial contractility). None has yet found general acceptance in anaesthesia and critical care as a practical method. We report a novel approach to the determination of inotropy as a bedside procedure which could identify low inotropy states in patients with clinical heart failure. We estimated the potential and kinetic energy delivered by the left ventricle using continuous-wave Doppler ultrasound (ultrasonic cardiac output monitor, Uscom, Sydney, Australia) and data available at the point of care. A formula to calculate effective inotropy [Smith-Madigan inotropy index (SMII)] was tested against historical haemodynamic data for 250 control subjects (ASA I patients from preoperative clinic) and 83 patients with acute left ventricular failure (LVF) of New York Heart Association Grade 4 (LVF group). The ratio of potential to kinetic energy (PKR) was investigated as a measure of arterial impedance. Significant differences were found between the control and LVF groups for cardiac index, mean (range)=3.37 (2.84-5.32) vs 1.84 (1.43-2.26) litre min(-1) m(-2); stroke volume index (SVI), 49.2 (39-55) vs 34.3 (23-37) ml m(-2); systemic vascular resistance, 893 (644-1242) vs 1960 (1744-4048) dyn s cm(-5); SMII, 1.78 (1.35-2.24) vs 0.73 (0.43-0.97) W m(-2); and PKR, 29:1 (24-35:1) vs 124:1 (96-174:1), Pcalculated for SMII and PKR as mean (+/-1.96) standard deviations, yielding 1.6-2.2 W m(-2) for SMII, and 25-34:1 for PKR. The method clearly identified the two clinical groups with no overlap of data points. The discriminant power of SMII and PKR may offer valuable diagnostic methods and monitoring tools in anaesthesia and critical care. This is the first report of normal ranges for SMII and PKR.

  14. Preliminary results from EMERSITO, a rapid response network for site-effect studies

    Directory of Open Access Journals (Sweden)

    Paola Bordoni

    2012-10-01

    Full Text Available On May 20, 2012, at 02:03 UTC, a Ml 5.9 reverse-fault earthquake occurred in the Emilia-Romagna region, northern Italy, at a hypocentral depth of 6.3 km (http://iside.rm.ingv.it/, close to the cities of Modena and Ferrara in the plain of the Po River. The epicenter was near the village of Finale Emilia where macroseismic intensity was assessed at 7 EMS98 [Tertulliani et al. 2012, this issue], while the closest accelerometric station, MRN, located less than 20 km west-ward at Mirandola (Figure 1 recorded peaks of ground accelerations of about 300 cm/s2 (www.protezionecivile.gov.it/resources/cms/documents/Report_DPC_1_Emilia_EQSd.pdf. The mainshock triggered liquefaction phenomena a few kilometers eastwards of the epicenter, around the village of San Carlo. On the same day, two other shocks of Ml 5.1 followed (02:07, 13:18 GMT; http://iside.rm.ingv.it/. On May 29, 2012, at 07:00 UTC another Ml 5.8 earthquake hit the region (http://iside.rm.ingv.it/, with the epicenter close to the village of Mirandola (Figure 1. Three other strong aftershocks occurred afterwards, of Ml 5.3 (May 29, at 10:55, Ml 5.2 (May 29, at 11:00 and Ml 5.1 (June 3, at 19:20. For a detailed description of the seismic sequence, see Moretti et al. [2012], Scognamiglio et al. [2012], and Massa et al. [2012], in this issue. The Emilia seismic sequence resulted in 25 casualties, several of whom were among the workers in the many factories that collapsed during working hours, and there was extensive damage to monuments, public buildings, industrial sites, and private homes. […

  15. Accurate wavelength calibration method for compact CCD spectrometer.

    Science.gov (United States)

    Sun, Y C; Huang, C; Xia, G; Jin, S Q; Lu, H B

    2017-04-01

    Wavelength calibration is an important step in charge-coupled device (CCD) spectrometers. In this paper, an accurate calibration method is proposed. A model of a line profile spectrum is built at the beginning, followed by noise reduction, bandwidth correction, and automatic peak-seeking treatment. Experimental tests are conducted on the USB4000 spectrometer with a mercury-argon calibration light source. Compared with the traditional method, the results show that this wavelength calibration procedure obtains higher accuracy and the deviations are within 0.1 nm.

  16. An Accurate Technique for Calculation of Radiation From Printed Reflectarrays

    DEFF Research Database (Denmark)

    Zhou, Min; Sorensen, Stig B.; Jorgensen, Erik

    2011-01-01

    The accuracy of various techniques for calculating the radiation from printed reflectarrays is examined, and an improved technique based on the equivalent currents approach is proposed. The equivalent currents are found from a continuous plane wave spectrum calculated by use of the spectral dyadic...... Green's function. This ensures a correct relation between the equivalent electric and magnetic currents and thus allows an accurate calculation of the radiation over the entire far-field sphere. A comparison to DTU-ESA Facility measurements of a reference offset reflectarray designed and manufactured...

  17. Pink-Beam, Highly-Accurate Compact Water Cooled Slits

    Science.gov (United States)

    Lyndaker, Aaron; Deyhim, Alex; Jayne, Richard; Waterman, Dave; Caletka, Dave; Steadman, Paul; Dhesi, Sarnjeet

    2007-01-01

    Advanced Design Consulting, Inc. (ADC) has designed accurate compact slits for applications where high precision is required. The system consists of vertical and horizontal slit mechanisms, a vacuum vessel which houses them, water cooling lines with vacuum guards connected to the individual blades, stepper motors with linear encoders, limit (home position) switches and electrical connections including internal wiring for a drain current measurement system. The total slit size is adjustable from 0 to 15 mm both vertically and horizontally. Each of the four blades are individually controlled and motorized. In this paper, a summary of the design and Finite Element Analysis of the system are presented.

  18. Precise and accurate isotopic measurements using multiple-collector ICPMS

    Science.gov (United States)

    Albarède, F.; Telouk, Philippe; Blichert-Toft, Janne; Boyet, Maud; Agranier, Arnaud; Nelson, Bruce

    2004-06-01

    New techniques of isotopic measurements by a new generation of mass spectrometers equipped with an inductively-coupled-plasma source, a magnetic mass filter, and multiple collection (MC-ICPMS) are quickly developing. These techniques are valuable because of (1) the ability of ICP sources to ionize virtually every element in the periodic table, and (2) the large sample throughout. However, because of the complex trajectories of multiple ion beams produced in the plasma source whether from the same or different elements, the acquisition of precise and accurate isotopic data with this type of instrument still requires a good understanding of instrumental fractionation processes, both mass-dependent and mass-independent. Although physical processes responsible for the instrumental mass bias are still to be understood more fully, we here present a theoretical framework that allows for most of the analytical limitations to high precision and accuracy to be overcome. After a presentation of unifying phenomenological theory for mass-dependent fractionation in mass spectrometers, we show how this theory accounts for the techniques of standard bracketing and of isotopic normalization by a ratio of either the same or a different element, such as the use of Tl to correct mass bias on Pb. Accuracy is discussed with reference to the concept of cup efficiencies. Although these can be simply calibrated by analyzing standards, we derive a straightforward, very general method to calculate accurate isotopic ratios from dynamic measurements. In this study, we successfully applied the dynamic method to Nd and Pb as examples. We confirm that the assumption of identical mass bias for neighboring elements (notably Pb and Tl, and Yb and Lu) is both unnecessary and incorrect. We further discuss the dangers of straightforward standard-sample bracketing when chemical purification of the element to be analyzed is imperfect. Pooling runs to improve precision is acceptable provided the pooled

  19. Quantum-Accurate Molecular Dynamics Potential for Tungsten

    Energy Technology Data Exchange (ETDEWEB)

    Wood, Mitchell; Thompson, Aidan P.

    2017-03-01

    The purpose of this short contribution is to report on the development of a Spectral Neighbor Analysis Potential (SNAP) for tungsten. We have focused on the characterization of elastic and defect properties of the pure material in order to support molecular dynamics simulations of plasma-facing materials in fusion reactors. A parallel genetic algorithm approach was used to efficiently search for fitting parameters optimized against a large number of objective functions. In addition, we have shown that this many-body tungsten potential can be used in conjunction with a simple helium pair potential1 to produce accurate defect formation energies for the W-He binary system.

  20. Accurate analysis of multitone signals using a DFT

    Science.gov (United States)

    Burgess, John C.

    2004-07-01

    Optimum data windows make it possible to determine accurately the amplitude, phase, and frequency of one or more tones (sinusoidal components) in a signal. Procedures presented in this paper can be applied to noisy signals, signals having moderate nonstationarity, and tones close in frequency. They are relevant to many areas of acoustics where sounds are quasistationary. Among these are acoustic probes transmitted through media and natural sounds, such as animal vocalization, speech, and music. The paper includes criteria for multitone FFT block design and an example of application to sound transmission in the atmosphere.

  1. Accurate Programming: Thinking about programs in terms of properties

    Directory of Open Access Journals (Sweden)

    Walid Taha

    2011-09-01

    Full Text Available Accurate programming is a practical approach to producing high quality programs. It combines ideas from test-automation, test-driven development, agile programming, and other state of the art software development methods. In addition to building on approaches that have proven effective in practice, it emphasizes concepts that help programmers sharpen their understanding of both the problems they are solving and the solutions they come up with. This is achieved by encouraging programmers to think about programs in terms of properties.

  2. Accurate ocean bottom seismometer positioning method inspired by multilateration technique

    Science.gov (United States)

    Benazzouz, Omar; Pinheiro, Luis M.; Matias, Luis M. A.; Afilhado, Alexandra; Herold, Daniel; Haines, Seth S.

    2018-01-01

    The positioning of ocean bottom seismometers (OBS) is a key step in the processing flow of OBS data, especially in the case of self popup types of OBS instruments. The use of first arrivals from airgun shots, rather than relying on the acoustic transponders mounted in the OBS, is becoming a trend and generally leads to more accurate positioning due to the statistics from a large number of shots. In this paper, a linearization of the OBS positioning problem via the multilateration technique is discussed. The discussed linear solution solves jointly for the average water layer velocity and the OBS position using only shot locations and first arrival times as input data.

  3. Calibration Techniques for Accurate Measurements by Underwater Camera Systems

    Science.gov (United States)

    Shortis, Mark

    2015-01-01

    Calibration of a camera system is essential to ensure that image measurements result in accurate estimates of locations and dimensions within the object space. In the underwater environment, the calibration must implicitly or explicitly model and compensate for the refractive effects of waterproof housings and the water medium. This paper reviews the different approaches to the calibration of underwater camera systems in theoretical and practical terms. The accuracy, reliability, validation and stability of underwater camera system calibration are also discussed. Samples of results from published reports are provided to demonstrate the range of possible accuracies for the measurements produced by underwater camera systems. PMID:26690172

  4. Accurate strand-specific quantification of viral RNA.

    Directory of Open Access Journals (Sweden)

    Nicole E Plaskon

    Full Text Available The presence of full-length complements of viral genomic RNA is a hallmark of RNA virus replication within an infected cell. As such, methods for detecting and measuring specific strands of viral RNA in infected cells and tissues are important in the study of RNA viruses. Strand-specific quantitative real-time PCR (ssqPCR assays are increasingly being used for this purpose, but the accuracy of these assays depends on the assumption that the amount of cDNA measured during the quantitative PCR (qPCR step accurately reflects amounts of a specific viral RNA strand present in the RT reaction. To specifically test this assumption, we developed multiple ssqPCR assays for the positive-strand RNA virus o'nyong-nyong (ONNV that were based upon the most prevalent ssqPCR assay design types in the literature. We then compared various parameters of the ONNV-specific assays. We found that an assay employing standard unmodified virus-specific primers failed to discern the difference between cDNAs generated from virus specific primers and those generated through false priming. Further, we were unable to accurately measure levels of ONNV (- strand RNA with this assay when higher levels of cDNA generated from the (+ strand were present. Taken together, these results suggest that assays of this type do not accurately quantify levels of the anti-genomic strand present during RNA virus infectious cycles. However, an assay permitting the use of a tag-specific primer was able to distinguish cDNAs transcribed from ONNV (- strand RNA from other cDNAs present, thus allowing accurate quantification of the anti-genomic strand. We also report the sensitivities of two different detection strategies and chemistries, SYBR(R Green and DNA hydrolysis probes, used with our tagged ONNV-specific ssqPCR assays. Finally, we describe development, design and validation of ssqPCR assays for chikungunya virus (CHIKV, the recent cause of large outbreaks of disease in the Indian Ocean

  5. Accurate Excited State Geometries within Reduced Subspace TDDFT/TDA.

    Science.gov (United States)

    Robinson, David

    2014-12-09

    A method for the calculation of TDDFT/TDA excited state geometries within a reduced subspace of Kohn-Sham orbitals has been implemented and tested. Accurate geometries are found for all of the fluorophore-like molecules tested, with at most all valence occupied orbitals and half of the virtual orbitals included but for some molecules even fewer orbitals. Efficiency gains of between 15 and 30% are found for essentially the same level of accuracy as a standard TDDFT/TDA excited state geometry optimization calculation.

  6. Topaz II preliminary safety assessment

    Science.gov (United States)

    Marshall, Albert C.; Standley, Vaughn; Voss, Susan S.; Haskin, Eric

    1993-01-01

    The Strategic Defense Initiative Organization (SDIO) decided to investigate the possibility of launching a Russian Topaz II space nuclear power system. A preliminary safety assessment was conducted to determine whether or not a space mission could be conducted safely and within budget constraints. As part of this assessment, a safety policy and safety functional requirements were developed to guide both the safety assessment and future Topaz II activities. A review of the Russian flight safety program was conducted and documented. Our preliminary safety assessment included a top level event tree, neutronic analysis of normal and accident configurations, an evaluation of temperature coefficients of reactivity, a reentry and disposal analysis, and analysis of postulated launch abort impact accidents, and an analysis of postulated propellant fire and explosion accidents. Based on the assessment, it appears that it will be possible to safely launch the Topaz II system in the U.S. with some possible system modifications. The principal system modifications will probably include design changes to preclude water flooded criticality and to assure intact reentry.

  7. Preliminary Estimation of Kappa Parameter in Croatia

    Science.gov (United States)

    Stanko, Davor; Markušić, Snježana; Ivančić, Ines; Mario, Gazdek; Gülerce, Zeynep

    2017-12-01

    Spectral parameter kappa κ is used to describe spectral amplitude decay “crash syndrome” at high frequencies. The purpose of this research is to estimate spectral parameter kappa for the first time in Croatia based on small and moderate earthquakes. Recordings of local earthquakes with magnitudes higher than 3, epicentre distances less than 150 km, and focal depths less than 30 km from seismological stations in Croatia are used. The value of kappa was estimated from the acceleration amplitude spectrum of shear waves from the slope of the high-frequency part where the spectrum starts to decay rapidly to a noise floor. Kappa models as a function of a site and distance were derived from a standard linear regression of kappa-distance dependence. Site kappa was determined from the extrapolation of the regression line to a zero distance. The preliminary results of site kappa across Croatia are promising. In this research, these results are compared with local site condition parameters for each station, e.g. shear wave velocity in the upper 30 m from geophysical measurements and with existing global shear wave velocity – site kappa values. Spatial distribution of individual kappa’s is compared with the azimuthal distribution of earthquake epicentres. These results are significant for a couple of reasons: to extend the knowledge of the attenuation of near-surface crust layers of the Dinarides and to provide additional information on the local earthquake parameters for updating seismic hazard maps of studied area. Site kappa can be used in the re-creation, and re-calibration of attenuation of peak horizontal and/or vertical acceleration in the Dinarides area since information on the local site conditions were not included in the previous studies.

  8. Can rapid assessment protocols be used to judge sediment impairment in gravel-bed streams? A commentary

    Science.gov (United States)

    Thomas E. Lisle; John M. Buffington; Peter R. Wilcock; Kristin Bunte

    2015-01-01

    Land management agencies commonly use rapid assessments to evaluate the impairment of gravel-bed streams by sediment inputs from anthropogenic sources. We question whether rapid assessment can be used to reliably judge sediment impairment at a site or in a region. Beyond the challenges of repeatable and accurate sampling, we argue that a single metric or protocol is...

  9. Pediatric specific shock index accurately identifies severely injured children.

    Science.gov (United States)

    Acker, Shannon N; Ross, James T; Partrick, David A; Tong, Suhong; Bensard, Denis D

    2015-02-01

    Shock index (SI) (heart rate/systolic blood pressure)>0.9 predicts mortality in adult trauma patients. We hypothesized that age adjusted SI could more accurately predict outcomes in children. Retrospective review of children age 4-16 years admitted to two trauma centers between 1/07 and 6/13 following blunt trauma with an injury severity score (ISS)>15 was performed. We evaluated the ability of SI>0.9 at emergency department presentation and elevated shock index, pediatric age adjusted (SIPA) to predict outcomes. SIPA was defined by maximum normal HR and minimum normal SBP by age. Cutoffs included SI>1.22 (age 4-6), >1.0 (7-12), and >0.9 (13-16). Among 543 children, 50% of children had an SI>0.9 but this fell to 28% using age adjusted SI (SIPA). SIPA demonstrated improved discrimination of severe injury relative to SI: ISS>30: 37% vs 26%; blood transfusion within the first 24 hours: 27% vs 20%; Grade III liver/spleen laceration requiring blood transfusion: 41% vs 26%; and in-hospital mortality: 11% vs 7%. A pediatric specific shock index (SIPA) more accurately identifies children who are most severely injured, have intraabdominal injury requiring transfusion, and are at highest risk of death when compared to shock index unadjusted for age. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Automatic and Accurate Shadow Detection Using Near-Infrared Information.

    Science.gov (United States)

    Rüfenacht, Dominic; Fredembach, Clément; Süsstrunk, Sabine

    2014-08-01

    We present a method to automatically detect shadows in a fast and accurate manner by taking advantage of the inherent sensitivity of digital camera sensors to the near-infrared (NIR) part of the spectrum. Dark objects, which confound many shadow detection algorithms, often have much higher reflectance in the NIR. We can thus build an accurate shadow candidate map based on image pixels that are dark both in the visible and NIR representations. We further refine the shadow map by incorporating ratios of the visible to the NIR image, based on the observation that commonly encountered light sources have very distinct spectra in the NIR band. The results are validated on a new database, which contains visible/NIR images for a large variety of real-world shadow creating illuminant conditions, as well as manually labeled shadow ground truth. Both quantitative and qualitative evaluations show that our method outperforms current state-of-the-art shadow detection algorithms in terms of accuracy and computational efficiency.

  11. Accurate colon residue detection algorithm with partial volume segmentation

    Science.gov (United States)

    Li, Xiang; Liang, Zhengrong; Zhang, PengPeng; Kutcher, Gerald J.

    2004-05-01

    Colon cancer is the second leading cause of cancer-related death in the United States. Earlier detection and removal of polyps can dramatically reduce the chance of developing malignant tumor. Due to some limitations of optical colonoscopy used in clinic, many researchers have developed virtual colonoscopy as an alternative technique, in which accurate colon segmentation is crucial. However, partial volume effect and existence of residue make it very challenging. The electronic colon cleaning technique proposed by Chen et al is a very attractive method, which is also kind of hard segmentation method. As mentioned in their paper, some artifacts were produced, which might affect the accurate colon reconstruction. In our paper, instead of labeling each voxel with a unique label or tissue type, the percentage of different tissues within each voxel, which we call a mixture, was considered in establishing a maximum a posterior probability (MAP) image-segmentation framework. A Markov random field (MRF) model was developed to reflect the spatial information for the tissue mixtures. The spatial information based on hard segmentation was used to determine which tissue types are in the specific voxel. Parameters of each tissue class were estimated by the expectation-maximization (EM) algorithm during the MAP tissue-mixture segmentation. Real CT experimental results demonstrated that the partial volume effects between four tissue types have been precisely detected. Meanwhile, the residue has been electronically removed and very smooth and clean interface along the colon wall has been obtained.

  12. Ultra-accurate collaborative information filtering via directed user similarity

    Science.gov (United States)

    Guo, Q.; Song, W.-J.; Liu, J.-G.

    2014-07-01

    A key challenge of the collaborative filtering (CF) information filtering is how to obtain the reliable and accurate results with the help of peers' recommendation. Since the similarities from small-degree users to large-degree users would be larger than the ones in opposite direction, the large-degree users' selections are recommended extensively by the traditional second-order CF algorithms. By considering the users' similarity direction and the second-order correlations to depress the influence of mainstream preferences, we present the directed second-order CF (HDCF) algorithm specifically to address the challenge of accuracy and diversity of the CF algorithm. The numerical results for two benchmark data sets, MovieLens and Netflix, show that the accuracy of the new algorithm outperforms the state-of-the-art CF algorithms. Comparing with the CF algorithm based on random walks proposed by Liu et al. (Int. J. Mod. Phys. C, 20 (2009) 285) the average ranking score could reach 0.0767 and 0.0402, which is enhanced by 27.3% and 19.1% for MovieLens and Netflix, respectively. In addition, the diversity, precision and recall are also enhanced greatly. Without relying on any context-specific information, tuning the similarity direction of CF algorithms could obtain accurate and diverse recommendations. This work suggests that the user similarity direction is an important factor to improve the personalized recommendation performance.

  13. Accurate phylogenetic classification of DNA fragments based onsequence composition

    Energy Technology Data Exchange (ETDEWEB)

    McHardy, Alice C.; Garcia Martin, Hector; Tsirigos, Aristotelis; Hugenholtz, Philip; Rigoutsos, Isidore

    2006-05-01

    Metagenome studies have retrieved vast amounts of sequenceout of a variety of environments, leading to novel discoveries and greatinsights into the uncultured microbial world. Except for very simplecommunities, diversity makes sequence assembly and analysis a verychallenging problem. To understand the structure a 5 nd function ofmicrobial communities, a taxonomic characterization of the obtainedsequence fragments is highly desirable, yet currently limited mostly tothose sequences that contain phylogenetic marker genes. We show that forclades at the rank of domain down to genus, sequence composition allowsthe very accurate phylogenetic 10 characterization of genomic sequence.We developed a composition-based classifier, PhyloPythia, for de novophylogenetic sequence characterization and have trained it on adata setof 340 genomes. By extensive evaluation experiments we show that themethodis accurate across all taxonomic ranks considered, even forsequences that originate fromnovel organisms and are as short as 1kb.Application to two metagenome datasets 15 obtained from samples ofphosphorus-removing sludge showed that the method allows the accurateclassification at genus level of most sequence fragments from thedominant populations, while at the same time correctly characterizingeven larger parts of the samples at higher taxonomic levels.

  14. The economic value of accurate wind power forecasting to utilities

    Energy Technology Data Exchange (ETDEWEB)

    Watson, S.J. [Rutherford Appleton Lab., Oxfordshire (United Kingdom); Giebel, G.; Joensen, A. [Risoe National Lab., Dept. of Wind Energy and Atmospheric Physics, Roskilde (Denmark)

    1999-03-01

    With increasing penetrations of wind power, the need for accurate forecasting is becoming ever more important. Wind power is by its very nature intermittent. For utility schedulers this presents its own problems particularly when the penetration of wind power capacity in a grid reaches a significant level (>20%). However, using accurate forecasts of wind power at wind farm sites, schedulers are able to plan the operation of conventional power capacity to accommodate the fluctuating demands of consumers and wind farm output. The results of a study to assess the value of forecasting at several potential wind farm sites in the UK and in the US state of Iowa using the Reading University/Rutherford Appleton Laboratory National Grid Model (NGM) are presented. The results are assessed for different types of wind power forecasting, namely: persistence, optimised numerical weather prediction or perfect forecasting. In particular, it will shown how the NGM has been used to assess the value of numerical weather prediction forecasts from the Danish Meteorological Institute model, HIRLAM, and the US Nested Grid Model, which have been `site tailored` by the use of the linearized flow model WA{sup s}P and by various Model output Statistics (MOS) and autoregressive techniques. (au)

  15. Cerebral fat embolism: Use of MR spectroscopy for accurate diagnosis

    Directory of Open Access Journals (Sweden)

    Laxmi Kokatnur

    2015-01-01

    Full Text Available Cerebral fat embolism (CFE is an uncommon but serious complication following orthopedic procedures. It usually presents with altered mental status, and can be a part of fat embolism syndrome (FES if associated with cutaneous and respiratory manifestations. Because of the presence of other common factors affecting the mental status, particularly in the postoperative period, the diagnosis of CFE can be challenging. Magnetic resonance imaging (MRI of brain typically shows multiple lesions distributed predominantly in the subcortical region, which appear as hyperintense lesions on T2 and diffusion weighted images. Although the location offers a clue, the MRI findings are not specific for CFE. Watershed infarcts, hypoxic encephalopathy, disseminated infections, demyelinating disorders, diffuse axonal injury can also show similar changes on MRI of brain. The presence of fat in these hyperintense lesions, identified by MR spectroscopy as raised lipid peaks will help in accurate diagnosis of CFE. Normal brain tissue or conditions producing similar MRI changes will not show any lipid peak on MR spectroscopy. We present a case of CFE initially misdiagnosed as brain stem stroke based on clinical presentation and cranial computed tomography (CT scan, and later, MR spectroscopy elucidated the accurate diagnosis.

  16. Individual Differences in Accurately Judging Personality From Text.

    Science.gov (United States)

    Hall, Judith A; Goh, Jin X; Mast, Marianne Schmid; Hagedorn, Christian

    2016-08-01

    This research examines correlates of accuracy in judging Big Five traits from first-person text excerpts. Participants in six studies were recruited from psychology courses or online. In each study, participants performed a task of judging personality from text and performed other ability tasks and/or filled out questionnaires. Participants who were more accurate in judging personality from text were more likely to be female; had personalities that were more agreeable, conscientious, and feminine, and less neurotic and dominant (all controlling for participant gender); scored higher on empathic concern; self-reported more interest in, and attentiveness to, people's personalities in their daily lives; and reported reading more for pleasure, especially fiction. Accuracy was not associated with SAT scores but had a significant relation to vocabulary knowledge. Accuracy did not correlate with tests of judging personality and emotion based on audiovisual cues. This research is the first to address individual differences in accurate judgment of personality from text, thus adding to the literature on correlates of the good judge of personality. © 2015 Wiley Periodicals, Inc.

  17. Data fusion for accurate microscopic rough surface metrology

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Yuhang, E-mail: chenyh@ustc.edu.cn

    2016-06-15

    Data fusion for rough surface measurement and evaluation was analyzed on simulated datasets, one with higher density (HD) but lower accuracy and the other with lower density (LD) but higher accuracy. Experimental verifications were then performed on laser scanning microscopy (LSM) and atomic force microscopy (AFM) characterizations of surface areal roughness artifacts. The results demonstrated that the fusion based on Gaussian process models is effective and robust under different measurement biases and noise strengths. All the amplitude, height distribution, and spatial characteristics of the original sample structure can be precisely recovered, with better metrological performance than any individual measurements. As for the influencing factors, the HD noise has a relatively weaker effect as compared with the LD noise. Furthermore, to enable an accurate fusion, the ratio of LD sampling interval to surface autocorrelation length should be smaller than a critical threshold. In general, data fusion is capable of enhancing the nanometrology of rough surfaces by combining efficient LSM measurement and down-sampled fast AFM scan. The accuracy, resolution, spatial coverage and efficiency can all be significantly improved. It is thus expected to have potential applications in development of hybrid microscopy and in surface metrology. - Highlights: • Data fusion for rough surface nanometrology has been investigated. • Gaussian process based fusion is robust under different biases and noise strengths. • Sampling interval should be smaller than a threshold to enable accurate fusion. • Measurement accuracy, resolution, and efficiency can all be significantly improved. • Data fusion is expected to have potential applications in hybrid microscopy.

  18. An Accurate and Dynamic Computer Graphics Muscle Model

    Science.gov (United States)

    Levine, David Asher

    1997-01-01

    A computer based musculo-skeletal model was developed at the University in the departments of Mechanical and Biomedical Engineering. This model accurately represents human shoulder kinematics. The result of this model is the graphical display of bones moving through an appropriate range of motion based on inputs of EMGs and external forces. The need existed to incorporate a geometric muscle model in the larger musculo-skeletal model. Previous muscle models did not accurately represent muscle geometries, nor did they account for the kinematics of tendons. This thesis covers the creation of a new muscle model for use in the above musculo-skeletal model. This muscle model was based on anatomical data from the Visible Human Project (VHP) cadaver study. Two-dimensional digital images from the VHP were analyzed and reconstructed to recreate the three-dimensional muscle geometries. The recreated geometries were smoothed, reduced, and sliced to form data files defining the surfaces of each muscle. The muscle modeling function opened these files during run-time and recreated the muscle surface. The modeling function applied constant volume limitations to the muscle and constant geometry limitations to the tendons.

  19. Plant diversity accurately predicts insect diversity in two tropical landscapes.

    Science.gov (United States)

    Zhang, Kai; Lin, Siliang; Ji, Yinqiu; Yang, Chenxue; Wang, Xiaoyang; Yang, Chunyan; Wang, Hesheng; Jiang, Haisheng; Harrison, Rhett D; Yu, Douglas W

    2016-09-01

    Plant diversity surely determines arthropod diversity, but only moderate correlations between arthropod and plant species richness had been observed until Basset et al. (Science, 338, 2012 and 1481) finally undertook an unprecedentedly comprehensive sampling of a tropical forest and demonstrated that plant species richness could indeed accurately predict arthropod species richness. We now require a high-throughput pipeline to operationalize this result so that we can (i) test competing explanations for tropical arthropod megadiversity, (ii) improve estimates of global eukaryotic species diversity, and (iii) use plant and arthropod communities as efficient proxies for each other, thus improving the efficiency of conservation planning and of detecting forest degradation and recovery. We therefore applied metabarcoding to Malaise-trap samples across two tropical landscapes in China. We demonstrate that plant species richness can accurately predict arthropod (mostly insect) species richness and that plant and insect community compositions are highly correlated, even in landscapes that are large, heterogeneous and anthropogenically modified. Finally, we review how metabarcoding makes feasible highly replicated tests of the major competing explanations for tropical megadiversity. © 2016 John Wiley & Sons Ltd.

  20. Accurate Sample Time Reconstruction of Inertial FIFO Data

    Directory of Open Access Journals (Sweden)

    Sebastian Stieber

    2017-12-01

    Full Text Available In the context of modern cyber-physical systems, the accuracy of underlying sensor data plays an increasingly important role in sensor data fusion and feature extraction. The raw events of multiple sensors have to be aligned in time to enable high quality sensor fusion results. However, the growing number of simultaneously connected sensor devices make the energy saving data acquisition and processing more and more difficult. Hence, most of the modern sensors offer a first-in-first-out (FIFO interface to store multiple data samples and to relax timing constraints, when handling multiple sensor devices. However, using the FIFO interface increases the negative influence of individual clock drifts—introduced by fabrication inaccuracies, temperature changes and wear-out effects—onto the sampling data reconstruction. Furthermore, additional timing offset errors due to communication and software latencies increases with a growing number of sensor devices. In this article, we present an approach for an accurate sample time reconstruction independent of the actual clock drift with the help of an internal sensor timer. Such timers are already available in modern sensors, manufactured in micro-electromechanical systems (MEMS technology. The presented approach focuses on calculating accurate time stamps using the sensor FIFO interface in a forward-only processing manner as a robust and energy saving solution. The proposed algorithm is able to lower the overall standard deviation of reconstructed sampling periods below 40 μ s, while run-time savings of up to 42% are achieved, compared to single sample acquisition.

  1. Accurate Sample Time Reconstruction of Inertial FIFO Data.

    Science.gov (United States)

    Stieber, Sebastian; Dorsch, Rainer; Haubelt, Christian

    2017-12-13

    In the context of modern cyber-physical systems, the accuracy of underlying sensor data plays an increasingly important role in sensor data fusion and feature extraction. The raw events of multiple sensors have to be aligned in time to enable high quality sensor fusion results. However, the growing number of simultaneously connected sensor devices make the energy saving data acquisition and processing more and more difficult. Hence, most of the modern sensors offer a first-in-first-out (FIFO) interface to store multiple data samples and to relax timing constraints, when handling multiple sensor devices. However, using the FIFO interface increases the negative influence of individual clock drifts-introduced by fabrication inaccuracies, temperature changes and wear-out effects-onto the sampling data reconstruction. Furthermore, additional timing offset errors due to communication and software latencies increases with a growing number of sensor devices. In this article, we present an approach for an accurate sample time reconstruction independent of the actual clock drift with the help of an internal sensor timer. Such timers are already available in modern sensors, manufactured in micro-electromechanical systems (MEMS) technology. The presented approach focuses on calculating accurate time stamps using the sensor FIFO interface in a forward-only processing manner as a robust and energy saving solution. The proposed algorithm is able to lower the overall standard deviation of reconstructed sampling periods below 40 μ s, while run-time savings of up to 42% are achieved, compared to single sample acquisition.

  2. Learning fast accurate movements requires intact frontostriatal circuits.

    Science.gov (United States)

    Shabbott, Britne; Ravindran, Roshni; Schumacher, Joseph W; Wasserman, Paula B; Marder, Karen S; Mazzoni, Pietro

    2013-01-01

    The basal ganglia are known to play a crucial role in movement execution, but their importance for motor skill learning remains unclear. Obstacles to our understanding include the lack of a universally accepted definition of motor skill learning (definition confound), and difficulties in distinguishing learning deficits from execution impairments (performance confound). We studied how healthy subjects and subjects with a basal ganglia disorder learn fast accurate reaching movements. We addressed the definition and performance confounds by: (1) focusing on an operationally defined core element of motor skill learning (speed-accuracy learning), and (2) using normal variation in initial performance to separate movement execution impairment from motor learning abnormalities. We measured motor skill learning as performance improvement in a reaching task with a speed-accuracy trade-off. We compared the performance of subjects with Huntington's disease (HD), a neurodegenerative basal ganglia disorder, to that of premanifest carriers of the HD mutation and of control subjects. The initial movements of HD subjects were less skilled (slower and/or less accurate) than those of control subjects. To factor out these differences in initial execution, we modeled the relationship between learning and baseline performance in control subjects. Subjects with HD exhibited a clear learning impairment that was not explained by differences in initial performance. These results support a role for the basal ganglia in both movement execution and motor skill learning.

  3. Accurate measurement of streamwise vortices using dual-plane PIV

    Science.gov (United States)

    Waldman, Rye M.; Breuer, Kenneth S.

    2012-11-01

    Low Reynolds number aerodynamic experiments with flapping animals (such as bats and small birds) are of particular interest due to their application to micro air vehicles which operate in a similar parameter space. Previous PIV wake measurements described the structures left by bats and birds and provided insight into the time history of their aerodynamic force generation; however, these studies have faced difficulty drawing quantitative conclusions based on said measurements. The highly three-dimensional and unsteady nature of the flows associated with flapping flight are major challenges for accurate measurements. The challenge of animal flight measurements is finding small flow features in a large field of view at high speed with limited laser energy and camera resolution. Cross-stream measurement is further complicated by the predominately out-of-plane flow that requires thick laser sheets and short inter-frame times, which increase noise and measurement uncertainty. Choosing appropriate experimental parameters requires compromise between the spatial and temporal resolution and the dynamic range of the measurement. To explore these challenges, we do a case study on the wake of a fixed wing. The fixed model simplifies the experiment and allows direct measurements of the aerodynamic forces via load cell. We present a detailed analysis of the wake measurements, discuss the criteria for making accurate measurements, and present a solution for making quantitative aerodynamic load measurements behind free-flyers.

  4. Accurate Multisteps Traffic Flow Prediction Based on SVM

    Directory of Open Access Journals (Sweden)

    Zhang Mingheng

    2013-01-01

    Full Text Available Accurate traffic flow prediction is prerequisite and important for realizing intelligent traffic control and guidance, and it is also the objective requirement for intelligent traffic management. Due to the strong nonlinear, stochastic, time-varying characteristics of urban transport system, artificial intelligence methods such as support vector machine (SVM are now receiving more and more attentions in this research field. Compared with the traditional single-step prediction method, the multisteps prediction has the ability that can predict the traffic state trends over a certain period in the future. From the perspective of dynamic decision, it is far important than the current traffic condition obtained. Thus, in this paper, an accurate multi-steps traffic flow prediction model based on SVM was proposed. In which, the input vectors were comprised of actual traffic volume and four different types of input vectors were compared to verify their prediction performance with each other. Finally, the model was verified with actual data in the empirical analysis phase and the test results showed that the proposed SVM model had a good ability for traffic flow prediction and the SVM-HPT model outperformed the other three models for prediction.

  5. Accurately controlled sequential self-folding structures by polystyrene film

    Science.gov (United States)

    Deng, Dongping; Yang, Yang; Chen, Yong; Lan, Xing; Tice, Jesse

    2017-08-01

    Four-dimensional (4D) printing overcomes the traditional fabrication limitations by designing heterogeneous materials to enable the printed structures evolve over time (the fourth dimension) under external stimuli. Here, we present a simple 4D printing of self-folding structures that can be sequentially and accurately folded. When heated above their glass transition temperature pre-strained polystyrene films shrink along the XY plane. In our process silver ink traces printed on the film are used to provide heat stimuli by conducting current to trigger the self-folding behavior. The parameters affecting the folding process are studied and discussed. Sequential folding and accurately controlled folding angles are achieved by using printed ink traces and angle lock design. Theoretical analyses are done to guide the design of the folding processes. Programmable structures such as a lock and a three-dimensional antenna are achieved to test the feasibility and potential applications of this method. These self-folding structures change their shapes after fabrication under controlled stimuli (electric current) and have potential applications in the fields of electronics, consumer devices, and robotics. Our design and fabrication method provides an easy way by using silver ink printed on polystyrene films to 4D print self-folding structures for electrically induced sequential folding with angular control.

  6. Kalign – an accurate and fast multiple sequence alignment algorithm

    Directory of Open Access Journals (Sweden)

    Sonnhammer Erik LL

    2005-12-01

    Full Text Available Abstract Background The alignment of multiple protein sequences is a fundamental step in the analysis of biological data. It has traditionally been applied to analyzing protein families for conserved motifs, phylogeny, structural properties, and to improve sensitivity in homology searching. The availability of complete genome sequences has increased the demands on multiple sequence alignment (MSA programs. Current MSA methods suffer from being either too inaccurate or too computationally expensive to be applied effectively in large-scale comparative genomics. Results We developed Kalign, a method employing the Wu-Manber string-matching algorithm, to improve both the accuracy and speed of multiple sequence alignment. We compared the speed and accuracy of Kalign to other popular methods using Balibase, Prefab, and a new large test set. Kalign was as accurate as the best other methods on small alignments, but significantly more accurate when aligning large and distantly related sets of sequences. In our comparisons, Kalign was about 10 times faster than ClustalW and, depending on the alignment size, up to 50 times faster than popular iterative methods. Conclusion Kalign is a fast and robust alignment method. It is especially well suited for the increasingly important task of aligning large numbers of sequences.

  7. Is Cancer Information Exchanged on Social Media Scientifically Accurate?

    Science.gov (United States)

    Gage-Bouchard, Elizabeth A; LaValley, Susan; Warunek, Molli; Beaupin, Lynda Kwon; Mollica, Michelle

    2017-07-19

    Cancer patients and their caregivers are increasingly using social media as a platform to share cancer experiences, connect with support, and exchange cancer-related information. Yet, little is known about the nature and scientific accuracy of cancer-related information exchanged on social media. We conducted a content analysis of 12 months of data from 18 publically available Facebook Pages hosted by parents of children with acute lymphoblastic leukemia (N = 15,852 posts) and extracted all exchanges of medically-oriented cancer information. We systematically coded for themes in the nature of cancer-related information exchanged on personal Facebook Pages and two oncology experts independently evaluated the scientific accuracy of each post. Of the 15,852 total posts, 171 posts contained medically-oriented cancer information. The most frequent type of cancer information exchanged was information related to treatment protocols and health services use (35%) followed by information related to side effects and late effects (26%), medication (16%), medical caregiving strategies (13%), alternative and complementary therapies (8%), and other (2%). Overall, 67% of all cancer information exchanged was deemed medically/scientifically accurate, 19% was not medically/scientifically accurate, and 14% described unproven treatment modalities. These findings highlight the potential utility of social media as a cancer-related resource, but also indicate that providers should focus on recommending reliable, evidence-based sources to patients and caregivers.

  8. Accurate Evaluation Method of Molecular Binding Affinity from Fluctuation Frequency

    Science.gov (United States)

    Hoshino, Tyuji; Iwamoto, Koji; Ode, Hirotaka; Ohdomari, Iwao

    2008-05-01

    Exact estimation of the molecular binding affinity is significantly important for drug discovery. The energy calculation is a direct method to compute the strength of the interaction between two molecules. This energetic approach is, however, not accurate enough to evaluate a slight difference in binding affinity when distinguishing a prospective substance from dozens of candidates for medicine. Hence more accurate estimation of drug efficacy in a computer is currently demanded. Previously we proposed a concept of estimating molecular binding affinity, focusing on the fluctuation at an interface between two molecules. The aim of this paper is to demonstrate the compatibility between the proposed computational technique and experimental measurements, through several examples for computer simulations of an association of human immunodeficiency virus type-1 (HIV-1) protease and its inhibitor (an example for a drug-enzyme binding), a complexation of an antigen and its antibody (an example for a protein-protein binding), and a combination of estrogen receptor and its ligand chemicals (an example for a ligand-receptor binding). The proposed affinity estimation has proven to be a promising technique in the advanced stage of the discovery and the design of drugs.

  9. Surgeon-performed ultrasound: accurate, reproducible, and more efficient.

    Science.gov (United States)

    Wyrick, Deidre L; Smith, Samuel D; Burford, Jeffrey M; Dassinger, Melvin S

    2015-12-01

    A study previously performed at our institution demonstrated that surgeon-performed ultrasound (SPUS) was accurate compared to radiology department ultrasound (RDUS) when evaluating children with suspected appendicitis. The purpose of this study was to determine if these results were reproducible and if SPUS decreased time to definitive diagnosis. A surgery resident performed examinations and ultrasounds on children with suspected appendicitis. Final diagnosis was confirmed by pathology. Results were compared to RDUS and combined with the previous study for a final comparison with RDUS. Mean time to diagnosis was recorded. Data were analyzed using Fisher exact and Student's t test. Fifty-eight patients underwent SPUS, of these 35 had RDUS. The accuracy of SPUS alone was 93% (54/58) and RDUS accuracy was 94% (33/35) (p = 1). When SPUS was combined with clinical examination accuracy increased to 95% (55/58). When results were combined with the previous study, overall accuracy of SPUS was 90% (101/112) compared to overall RDUS accuracy of 89 % (50/56). Mean time to diagnosis for RDUS was 135 min (n = 35), whereas mean time to diagnosis for SPUS was 30 min (n = 58; p = 0.0001). SPUS is accurate and reproducible in evaluating children with suspected appendicitis. SPUS potentially decreases time to definitive therapy and emergency department wait times.

  10. A Weight-Averaged Interpolation Method for Coupling Time-Accurate Rarefied and Continuum Flows

    Science.gov (United States)

    Diaz, Steven William

    A novel approach to coupling rarefied and continuum flow regimes as a single, hybrid model is introduced. The method borrows from techniques used in the simulation of spray flows to interpolate Lagrangian point-particles onto an Eulerian grid in a weight-averaged sense. A brief overview of traditional methods for modeling both rarefied and continuum domains is given, and a review of the literature regarding rarefied/continuum flow coupling is presented. Details of the theoretical development of the method of weighted interpolation are then described. The method evaluates macroscopic properties at the nodes of a CFD grid via the weighted interpolation of all simulated molecules in a set surrounding the node. The weight factor applied to each simulated molecule is the inverse of the linear distance between it and the given node. During development, the method was applied to several preliminary cases, including supersonic flow over an airfoil, subsonic flow over tandem airfoils, and supersonic flow over a backward facing step; all at low Knudsen numbers. The main thrust of the research centered on the time-accurate expansion of a rocket plume into a near-vacuum. The method proves flexible enough to be used with various flow solvers, demonstrated by the use of Fluent as the continuum solver for the preliminary cases and a NASA-developed Large Eddy Simulation research code, WRLES, for the full lunar model. The method is applicable to a wide range of Mach numbers and is completely grid independent, allowing the rarefied and continuum solvers to be optimized for their respective domains without consideration of the other. The work presented demonstrates the validity, and flexibility of the method of weighted interpolation as a novel concept in the field of hybrid flow coupling. The method marks a significant divergence from current practices in the coupling of rarefied and continuum flow domains and offers a kernel on which to base an ongoing field of research. It has the

  11. Regulatory and Permitting Information Desktop (RAPID) Toolkit (Poster)

    Energy Technology Data Exchange (ETDEWEB)

    Young, K. R.; Levine, A.

    2014-09-01

    The Regulatory and Permitting Information Desktop (RAPID) Toolkit combines the former Geothermal Regulatory Roadmap, National Environmental Policy Act (NEPA) Database, and other resources into a Web-based tool that gives the regulatory and utility-scale geothermal developer communities rapid and easy access to permitting information. RAPID currently comprises five tools - Permitting Atlas, Regulatory Roadmap, Resource Library, NEPA Database, and Best Practices. A beta release of an additional tool, the Permitting Wizard, is scheduled for late 2014. Because of the huge amount of information involved, RAPID was developed in a wiki platform to allow industry and regulatory agencies to maintain the content in the future so that it continues to provide relevant and accurate information to users. In 2014, the content was expanded to include regulatory requirements for utility-scale solar and bulk transmission development projects. Going forward, development of the RAPID Toolkit will focus on expanding the capabilities of current tools, developing additional tools, including additional technologies, and continuing to increase stakeholder involvement.

  12. Research on the Reform of the Preliminary Course of Architectural Design Based on Innovation & Practice Ability Training

    Science.gov (United States)

    Yuping, Cai; Shuang, Liang

    2017-01-01

    The traditional undergraduate education mode of architecture has been unable to adapt to the rapid development of society. Taking the junior professional course of architecture--the preliminary course of architectural design as an example, this paper analyzes the problems existing in the current professional courses of lower grades, puts forward…

  13. Rapid Measurement of Tectonic Deformation Using Structure-from-Motion

    Science.gov (United States)

    Pickering, A.; DeLong, S.; Lienkaemper, J. J.; Hecker, S.; Prentice, C. S.; Schwartz, D. P.; Sickler, R. R.

    2016-12-01

    Rapid collection and distribution of accurate surface slip data after earthquakes can support emergency response, help coordinate scientific response, and constrain coseismic slip that can be rapidly overprinted by postseismic slip, or eliminated as evidence of surface deformation is repaired or obscured. Analysis of earthquake deformation can be achieved quickly, repeatedly and inexpensively with the use of Structure-from-Motion (SfM) photogrammetry. Traditional methods of measuring surface slip (e.g. manual measurement with tape measures) have proven inconsistent and irreproducible, and sophisticated methods such as laser scanning require specialized equipment and longer field time. Here we present a simple, cost-effective workflow for rapid, three-dimensional imaging and measurement of features affected by earthquake rupture. As part of a response drill performed by the USGS and collaborators on May 11, 2016, geologists documented offset cultural features along the creeping Hayward Fault in northern California, in simulation of a surface-rupturing earthquake. We present several photo collections from smart phones, tablets, and DSLR cameras from a number of locations along the fault collected by users with a range of experience. Using professionally calibrated photogrammetric scale bars we automatically and accurately scale our 3D models to 1 mm accuracy for precise measurement in three dimensions. We then generate scaled 3D point clouds and extract offsets from manual measurement and multiple linear regression for comparison with collected terrestrial scanner data. These results further establish dense photo collection and SfM processing as an important, low-cost, rapid means of quantifying surface deformation in the critical hours after a surface-rupturing earthquake and emphasize that researchers with minimal training can rapidly collect three-dimensional data that can be used to analyze and archive the surface effects of damaging earthquakes.

  14. Preliminary Context Analysis of Community Informatics Social ...

    African Journals Online (AJOL)

    Preliminary context analysis is always part of the feasibility study phase in the development of information system for Community Development (CD) purposes. In this paper, a context model and a preliminary context analysis are presented for Social Network Web Application (SNWA) for CD in the Niger Delta region of ...

  15. Plutonium Immobilization Can Loading Preliminary Specifications

    Energy Technology Data Exchange (ETDEWEB)

    Kriikku, E.

    1998-11-25

    This report discusses the Plutonium Immobilization can loading preliminary equipment specifications and includes a process block diagram, process description, equipment list, preliminary equipment specifications, plan and elevation sketches, and some commercial catalogs. This report identifies loading pucks into cans and backfilling cans with helium as the top priority can loading development areas.

  16. 33 CFR 116.10 - Preliminary review.

    Science.gov (United States)

    2010-07-01

    ... bridge in question. (b) In the absence of any written complaint, the District Commander may decide, based... opinion, the complaint is justified and whether a Preliminary Investigation is warranted. (1) The District Commander's opinion as to whether or not the complaint warrants a Preliminary Investigation will be formed...

  17. 23 CFR 645.109 - Preliminary engineering.

    Science.gov (United States)

    2010-04-01

    ... 23 Highways 1 2010-04-01 2010-04-01 false Preliminary engineering. 645.109 Section 645.109 Highways FEDERAL HIGHWAY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION ENGINEERING AND TRAFFIC OPERATIONS UTILITIES Utility Relocations, Adjustments, and Reimbursement § 645.109 Preliminary engineering. (a) As...

  18. A preliminary study for quantitative assessment of upper limb proprioception.

    Science.gov (United States)

    Contu, Sara; Hussain, Asif; Masia, Lorenzo; Campolo, Domenico

    2016-08-01

    Proprioception, or sense of position and movement of the body, strongly correlates with motor recovery of the hemiplegic arm. The evaluation of the awareness of the location of joints in space involves measuring the accuracy of joint-angle replication. Robotic devices allow an accurate manipulation of joint movements necessary to assess proprioceptive status. This study evaluated the proprioceptive performance of healthy subjects by mean of the H-Man, a planar robot designed for upper-limb rehabilitation to gather preliminary normative data for neurorehabilitation applications. Twelve participants were equally divided into Aged and Young groups and were asked to indicate when their dominant hand position matched a predefined target in the contralateral, sagittal and ipsilateral direction. Results indicated a better performance for movements towards the contralateral target in terms of both absolute and signed error while there was not a significant effect of age group. Error variability was not affected by the target location and participants' age. The present study established preliminary proprioceptive metrics that could assist in providing information about the normal range of proprioceptive acuity of healthy subjects of different age.

  19. The KFM, A Homemade Yet Accurate and Dependable Fallout Meter

    Energy Technology Data Exchange (ETDEWEB)

    Kearny, C.H.

    2001-11-20

    The KFM is a homemade fallout meter that can be made using only materials, tools, and skills found in millions of American homes. It is an accurate and dependable electroscope-capacitor. The KFM, in conjunction with its attached table and a watch, is designed for use as a rate meter. Its attached table relates observed differences in the separations of its two leaves (before and after exposures at the listed time intervals) to the dose rates during exposures of these time intervals. In this manner dose rates from 30 mR/hr up to 43 R/hr can be determined with an accuracy of {+-}25%. A KFM can be charged with any one of the three expedient electrostatic charging devices described. Due to the use of anhydrite (made by heating gypsum from wallboard) inside a KFM and the expedient ''dry-bucket'' in which it can be charged when the air is very humid, this instrument always can be charged and used to obtain accurate measurements of gamma radiation no matter how high the relative humidity. The heart of this report is the step-by-step illustrated instructions for making and using a KFM. These instructions have been improved after each successive field test. The majority of the untrained test families, adequately motivated by cash bonuses offered for success and guided only by these written instructions, have succeeded in making and using a KFM. NOTE: ''The KFM, A Homemade Yet Accurate and Dependable Fallout Meter'', was published by Oak Ridge National Laboratory report in1979. Some of the materials originally suggested for suspending the leaves of the Kearny Fallout Meter (KFM) are no longer available. Because of changes in the manufacturing process, other materials (e.g., sewing thread, unwaxed dental floss) may not have the insulating capability to work properly. Oak Ridge National Laboratory has not tested any of the suggestions provided in the preface of the report, but they have been used by other groups. When using these

  20. Preliminary Results Towards Contract Monitorability

    Directory of Open Access Journals (Sweden)

    Annalizz Vella

    2016-05-01

    Full Text Available This paper discusses preliminary investigations on the monitorability of contracts for web service descriptions. There are settings where servers do not guarantee statically whether they satisfy some specified contract, which forces the client (i.e., the entity interacting with the server to perform dynamic checks. This scenario may be viewed as an instance of Runtime Verification, where a pertinent question is whether contracts can be monitored for adequately at runtime, otherwise stated as the monitorability of contracts. We consider a simple language of finitary contracts describing both clients and servers, and develop a formal framework that describes server contract monitoring. We define monitor properties that potentially contribute towards a comprehensive notion of contract monitorability and show that our simple contract language satisfies these properties.

  1. Preliminary results of UCN τ

    Science.gov (United States)

    Pattie, Robert; UCNtau Collaboration

    2017-01-01

    There is currently a 4 σ discrepancy between measurements of the neutron lifetime performed using cold neutron beams and those performed with ultracold neutron (UCN) storage vessels. The UCN τ experiment uses an asymmetric magneto-gravitational UCN trap with in situ counting of surviving neutrons to measure the neutron lifetime. This design eliminates a major systematic of previous bottle experiments related to the loss of UCN on material trap walls and with unloading neutrons from the storage vessel. A new in situ detection system was used in the 2015-2016 run that was able to measure the population of surviving UCN at different heights in the trap, providing important information on spectral evolution. Understanding the behavior of quasi-bound UCN in a bottle experiment is essential to achieving a subsecond precision measurement of τn. We will present the preliminary results from the 2015-2016 data set and an update on the UCN τ experiment.

  2. KALIMER preliminary conceptual design report

    Energy Technology Data Exchange (ETDEWEB)

    Hahn, Do Hee; Kim, Y. J.; Kim, Y. G. and others

    2000-08-01

    This report, which summarizes the result of preliminary conceptual design activities during Phase 1, follows the format of safety analysis report. The purpose of publishing this report is to gather all of the design information developed so far in a systematic way so that KALIMER designers have a common source of the consistent design information necessary for their future design activities. This report will be revised and updated as design changes occur and more detailed design specification is developed during Phase 2. Chapter 1 describes the KALIMER Project. Chapter 2 includes the top level design requirements of KALIMER and general plant description. Chapter 3 summarizes the design of structures, components, equipment and systems. Specific systems and safety analysis results are described in the remaining chapters. Appendix on the HCDA evaluation is attached at the end of this report.

  3. Micromorphological and preliminary phytochemical studies of Azadirachta indica and Melia azedarach

    OpenAIRE

    JAFARI, Samineh; SAEIDNIA, Soodabeh; ARDEKANI, Mohammad Reza SHAMS; HADJIAKHOONDI, Abbas; KHANAVI, Mahnaz

    2013-01-01

    Azadirachta indica A.Juss. and Melia azedarach L. are 2 closely related species from Meliaceae that are considered noteworthy medicinal plants in the world and have very often been confused with each other. Various evaluations like organoleptic and microscopic characteristics, preliminary phytochemical screening, and fluorescence analysis were carried out on the pulp, husk, leaves, and seeds of both plants in powdered form to establish appropriate data that can aid rapid and easy differentiat...

  4. Preliminary hazards analysis -- vitrification process

    Energy Technology Data Exchange (ETDEWEB)

    Coordes, D.; Ruggieri, M.; Russell, J.; TenBrook, W.; Yimbo, P. [Science Applications International Corp., Pleasanton, CA (United States)

    1994-06-01

    This paper presents a Preliminary Hazards Analysis (PHA) for mixed waste vitrification by joule heating. The purpose of performing a PHA is to establish an initial hazard categorization for a DOE nuclear facility and to identify those processes and structures which may have an impact on or be important to safety. The PHA is typically performed during and provides input to project conceptual design. The PHA is then followed by a Preliminary Safety Analysis Report (PSAR) performed during Title 1 and 2 design. The PSAR then leads to performance of the Final Safety Analysis Report performed during the facility`s construction and testing. It should be completed before routine operation of the facility commences. This PHA addresses the first four chapters of the safety analysis process, in accordance with the requirements of DOE Safety Guidelines in SG 830.110. The hazards associated with vitrification processes are evaluated using standard safety analysis methods which include: identification of credible potential hazardous energy sources; identification of preventative features of the facility or system; identification of mitigative features; and analyses of credible hazards. Maximal facility inventories of radioactive and hazardous materials are postulated to evaluate worst case accident consequences. These inventories were based on DOE-STD-1027-92 guidance and the surrogate waste streams defined by Mayberry, et al. Radiological assessments indicate that a facility, depending on the radioactive material inventory, may be an exempt, Category 3, or Category 2 facility. The calculated impacts would result in no significant impact to offsite personnel or the environment. Hazardous materials assessment indicates that a Mixed Waste Vitrification facility will be a Low Hazard facility having minimal impacts to offsite personnel and the environment.

  5. Preliminary Evaluation of Mechanical Properties of Co-Cr Alloys Fabricated by Three New Manufacturing Processes.

    Science.gov (United States)

    Jang, Seong-Ho; Lee, Dae-Ho; Ha, Jung-Yun; Hanawa, Takao; Kim, Kyo-Han; Kwon, Tae-Yub

    2015-01-01

    A preliminary tensile test was performed to evaluate the mechanical properties of cobalt-chromium (Co-Cr) alloys fabricated by three new manufacturing processes: metal milling, milling for soft metal, and rapid prototyping (n=6). For comparison, the three alloy materials were also used to fabricate specimens by a casting procedure. In all groups tested, the proof strength and elongation were over 500 MPa and 2%, respectively. The milled soft alloy in particular showed a substantially greater elongation, whereas the alloy fabricated by rapid prototyping exhibited a higher proof strength.

  6. Accurate Holdup Calculations with Predictive Modeling & Data Integration

    Energy Technology Data Exchange (ETDEWEB)

    Azmy, Yousry [North Carolina State Univ., Raleigh, NC (United States). Dept. of Nuclear Engineering; Cacuci, Dan [Univ. of South Carolina, Columbia, SC (United States). Dept. of Mechanical Engineering

    2017-04-03

    In facilities that process special nuclear material (SNM) it is important to account accurately for the fissile material that enters and leaves the plant. Although there are many stages and processes through which materials must be traced and measured, the focus of this project is material that is “held-up” in equipment, pipes, and ducts during normal operation and that can accumulate over time into significant quantities. Accurately estimating the holdup is essential for proper SNM accounting (vis-à-vis nuclear non-proliferation), criticality and radiation safety, waste management, and efficient plant operation. Usually it is not possible to directly measure the holdup quantity and location, so these must be inferred from measured radiation fields, primarily gamma and less frequently neutrons. Current methods to quantify holdup, i.e. Generalized Geometry Holdup (GGH), primarily rely on simple source configurations and crude radiation transport models aided by ad hoc correction factors. This project seeks an alternate method of performing measurement-based holdup calculations using a predictive model that employs state-of-the-art radiation transport codes capable of accurately simulating such situations. Inverse and data assimilation methods use the forward transport model to search for a source configuration that best matches the measured data and simultaneously provide an estimate of the level of confidence in the correctness of such configuration. In this work the holdup problem is re-interpreted as an inverse problem that is under-determined, hence may permit multiple solutions. A probabilistic approach is applied to solving the resulting inverse problem. This approach rates possible solutions according to their plausibility given the measurements and initial information. This is accomplished through the use of Bayes’ Theorem that resolves the issue of multiple solutions by giving an estimate of the probability of observing each possible solution. To use

  7. Chip breaking for an automated accurate turning system

    Energy Technology Data Exchange (ETDEWEB)

    Burnham, M.W. (BDM Corp., Albuquerque, NM (USA)); Abbatiello, L.A. (Oak Ridge Y-12 Plant, TN (USA))

    1988-01-01

    Based upon a survey of chip breakup information, the various methods have been evaluated for application to automated accurate turning systems. Many chip breaking methods work well on shafts or cylinders but fail to break chips for an entire inside or outside contouring cut. Many metals produce straight or snarled chip forms at small depths of cut, feed rates, or moderate surface speeds. These chip forms can be a cause of workpiece and tool damage. Such forms also interfere with on-machine gaging, part transfer, and tool change. Often the chip wraps around the tool holder and is difficult to remove even in manual operation. Computer analysis now makes it possible to get the most of each types of chip breaking system. Reliable ship breaking is urgently needed for automated systems, especially those operating in an unmanned mode. 83 refs., 10 figs., 2 tabs.

  8. Accurate numerical methods for micromagnetics simulations with general geometries

    CERN Document Server

    García-Cervera, C J

    2003-01-01

    In current FFT-based algorithms for micromagnetics simulations, the boundary is typically replaced by a staircase approximation along the grid lines, either eliminating the incomplete cells or replacing them by complete cells. Sometimes the magnetizations at the boundary cells are weighted by the volume of the sample in the corresponding cell. We show that this leads to large errors in the computed exchange and stray fields. One consequence of this is that the predicted switching mechanism depends sensitively on the orientation of the numerical grid. We present a boundary-corrected algorithm to efficiently and accurately handle the incomplete cells at the boundary. We show that this boundary-corrected algorithm greatly improves the accuracy in micromagnetics simulations. We demonstrate by using A. Arrott's example of a hexagonal element that the switching mechanism is predicted independently of the grid orientation.

  9. Phase rainbow refractometry for accurate droplet variation characterization.

    Science.gov (United States)

    Wu, Yingchun; Promvongsa, Jantarat; Saengkaew, Sawitree; Wu, Xuecheng; Chen, Jia; Gréhan, Gérard

    2016-10-15

    We developed a one-dimensional phase rainbow refractometer for the accurate trans-dimensional measurements of droplet size on the micrometer scale as well as the tiny droplet diameter variations at the nanoscale. The dependence of the phase shift of the rainbow ripple structures on the droplet variations is revealed. The phase-shifting rainbow image is recorded by a telecentric one-dimensional rainbow imaging system. Experiments on the evaporating monodispersed droplet stream show that the phase rainbow refractometer can measure the tiny droplet diameter changes down to tens of nanometers. This one-dimensional phase rainbow refractometer is capable of measuring the droplet refractive index and diameter, as well as variations.

  10. Zadoff-Chu coded ultrasonic signal for accurate range estimation

    KAUST Repository

    AlSharif, Mohammed H.

    2017-11-02

    This paper presents a new adaptation of Zadoff-Chu sequences for the purpose of range estimation and movement tracking. The proposed method uses Zadoff-Chu sequences utilizing a wideband ultrasonic signal to estimate the range between two devices with very high accuracy and high update rate. This range estimation method is based on time of flight (TOF) estimation using cyclic cross correlation. The system was experimentally evaluated under different noise levels and multi-user interference scenarios. For a single user, the results show less than 7 mm error for 90% of range estimates in a typical indoor environment. Under the interference from three other users, the 90% error was less than 25 mm. The system provides high estimation update rate allowing accurate tracking of objects moving with high speed.

  11. Interactive Isogeometric Volume Visualization with Pixel-Accurate Geometry.

    Science.gov (United States)

    Fuchs, Franz G; Hjelmervik, Jon M

    2016-02-01

    A recent development, called isogeometric analysis, provides a unified approach for design, analysis and optimization of functional products in industry. Traditional volume rendering methods for inspecting the results from the numerical simulations cannot be applied directly to isogeometric models. We present a novel approach for interactive visualization of isogeometric analysis results, ensuring correct, i.e., pixel-accurate geometry of the volume including its bounding surfaces. The entire OpenGL pipeline is used in a multi-stage algorithm leveraging techniques from surface rendering, order-independent transparency, as well as theory and numerical methods for ordinary differential equations. We showcase the efficiency of our approach on different models relevant to industry, ranging from quality inspection of the parametrization of the geometry, to stress analysis in linear elasticity, to visualization of computational fluid dynamics results.

  12. Accurate assessment of exposure using tracer gas measurements

    DEFF Research Database (Denmark)

    Kierat, Wojciech; Bivolarova, Mariya; Zavrl, Eva

    2018-01-01

    Room airflow interaction, particularly in the breathing zone, is important to assess exposure to indoor air pollution. A breathing thermal manikin was used to simulate a room occupant with the convective boundary layer (CBL) generated around the body and the respiratory flow. Local airflow against...... the face of the manikin was applied to increase the complexity of the airflow interaction. CO2 was released at the armpits and N2O at the groin to simulate the respective bio-effluents generated at these two body sites. The tracer gas concentration at the mouth/nose of the manikin was measured with gas...... with a decrease in the response time of the gas analyzer. When only CBL was present, shorter measurement time was needed for the accurate concentration measurement of the tracer gas released close to the breathing zone. For more complex flow, as a result of CBL interaction with the exhalation flow, the needed...

  13. Accurate measure by weight of liquids in industry. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Muller, M.R.

    1992-12-12

    This research`s focus was to build a prototype of a computerized liquid dispensing system. This liquid metering system is based on the concept of altering the representative volume to account for temperature changes in the liquid to be dispensed. This is actualized by using a measuring tank and a temperature compensating displacement plunger. By constantly monitoring the temperature of the liquid, the plunger can be used to increase or decrease the specified volume to more accurately dispense liquid with a specified mass. In order to put the device being developed into proper engineering perspective, an extensive literature review was undertaken on all areas of industrial metering of liquids with an emphasis on gravimetric methods.

  14. Accurate measure by weight of liquids in industry

    Energy Technology Data Exchange (ETDEWEB)

    Muller, M.R.

    1992-12-12

    This research's focus was to build a prototype of a computerized liquid dispensing system. This liquid metering system is based on the concept of altering the representative volume to account for temperature changes in the liquid to be dispensed. This is actualized by using a measuring tank and a temperature compensating displacement plunger. By constantly monitoring the temperature of the liquid, the plunger can be used to increase or decrease the specified volume to more accurately dispense liquid with a specified mass. In order to put the device being developed into proper engineering perspective, an extensive literature review was undertaken on all areas of industrial metering of liquids with an emphasis on gravimetric methods.

  15. Accurate and efficient spin integration for particle accelerators

    Directory of Open Access Journals (Sweden)

    Dan T. Abell

    2015-02-01

    Full Text Available Accurate spin tracking is a valuable tool for understanding spin dynamics in particle accelerators and can help improve the performance of an accelerator. In this paper, we present a detailed discussion of the integrators in the spin tracking code gpuSpinTrack. We have implemented orbital integrators based on drift-kick, bend-kick, and matrix-kick splits. On top of the orbital integrators, we have implemented various integrators for the spin motion. These integrators use quaternions and Romberg quadratures to accelerate both the computation and the convergence of spin rotations. We evaluate their performance and accuracy in quantitative detail for individual elements as well as for the entire RHIC lattice. We exploit the inherently data-parallel nature of spin tracking to accelerate our algorithms on graphics processing units.

  16. Accurate mass measurements on neutron-deficient krypton isotopes

    CERN Document Server

    Rodríguez, D.; Äystö, J.; Beck, D.; Blaum, K.; Bollen, G.; Herfurth, F.; Jokinen, A.; Kellerbauer, A.; Kluge, H.-J.; Kolhinen, V.S.; Oinonen, M.; Sauvan, E.; Schwarz, S.

    2006-01-01

    The masses of $^{72–78,80,82,86}$Kr were measured directly with the ISOLTRAP Penning trap mass spectrometer at ISOLDE/CERN. For all these nuclides, the measurements yielded mass uncertainties below 10 keV. The ISOLTRAP mass values for $^{72–75}$Kr being more precise than the previous results obtained by means of other techniques, and thus completely determine the new values in the Atomic-Mass Evaluation. Besides the interest of these masses for nuclear astrophysics, nuclear structure studies, and Standard Model tests, these results constitute a valuable and accurate input to improve mass models. In this paper, we present the mass measurements and discuss the mass evaluation for these Kr isotopes.

  17. Accurate performance analysis of opportunistic decode-and-forward relaying

    KAUST Repository

    Tourki, Kamel

    2011-07-01

    In this paper, we investigate an opportunistic relaying scheme where the selected relay assists the source-destination (direct) communication. In our study, we consider a regenerative opportunistic relaying scheme in which the direct path may be considered unusable, and the destination may use a selection combining technique. We first derive the exact statistics of each hop, in terms of probability density function (PDF). Then, the PDFs are used to determine accurate closed form expressions for end-to-end outage probability for a transmission rate R. Furthermore, we evaluate the asymptotical performance analysis and the diversity order is deduced. Finally, we validate our analysis by showing that performance simulation results coincide with our analytical results over different network architectures. © 2011 IEEE.

  18. A method for accurate temperature measurement using infrared thermal camera.

    Science.gov (United States)

    Tokunaga, Tomoharu; Narushima, Takashi; Yonezawa, Tetsu; Sudo, Takayuki; Okubo, Shuichi; Komatsubara, Shigeyuki; Sasaki, Katsuhiro; Yamamoto, Takahisa

    2012-08-01

    The temperature distribution on a centre-holed thin foil of molybdenum, used as a sample and heated using a sample-heating holder for electron microscopy, was measured using an infrared thermal camera. The temperature on the heated foil area located near the heating stage of the heating holder is almost equal to the temperature on the heating stage. However, during the measurement of the temperature at the edge of the hole of the foil located farthest from the heating stage, a drop in temperature should be taken into consideration; however, so far, no method has been developed to locally measure the temperature distribution on the heated sample. In this study, a method for the accurate measurement of temperature distribution on heated samples for electron microscopy is discussed.

  19. Calculation of Accurate Hexagonal Discontinuity Factors for PARCS

    Energy Technology Data Exchange (ETDEWEB)

    Pounders. J., Bandini, B. R. , Xu, Y, and Downar, T. J.

    2007-11-01

    In this study we derive a methodology for calculating discontinuity factors consistent with the Triangle-based Polynomial Expansion Nodal (TPEN) method implemented in PARCS for hexagonal reactor geometries. The accuracy of coarse-mesh nodal methods is greatly enhanced by permitting flux discontinuities at node boundaries, but the practice of calculating discontinuity factors from infinite-medium (zero-current) single bundle calculations may not be sufficiently accurate for more challenging problems in which there is a large amount of internodal neutron streaming. The authors therefore derive a TPEN-based method for calculating discontinuity factors that are exact with respect to generalized equivalence theory. The method is validated by reproducing the reference solution for a small hexagonal core.

  20. Accurate positioning of long, flexible ARM's (Articulated Robotic Manipulator)

    Science.gov (United States)

    Malachowski, Michael J.

    1988-01-01

    An articulated robotic manipulator (ARM) system is being designed for space applications. Work being done on a concept utilizing an infinitely stiff laser beam for position reference is summarized. The laser beam is projected along the segments of the ARM, and the position is sensed by the beam rider modules (BRM) mounted on the distal ends of the segments. The BRM concept is the heart of the system. It utilizes a combination of lateral displacements and rotational and distance measurement sensors. These determine the relative position of the two ends of the segments with respect to each other in six degrees of freedom. The BRM measurement devices contain microprocessor controlled data acquisition and active positioning components. An indirect adaptive controller is used to accurately control the position of the ARM.

  1. Stereotypes of Age Differences in Personality Traits: Universal and Accurate?

    Science.gov (United States)

    Chan, Wayne; McCrae, Robert R.; De Fruyt, Filip; Jussim, Lee; Löckenhoff, Corinna E.; De Bolle, Marleen; Costa, Paul T.; Sutin, Angelina R.; Realo, Anu; Allik, Jüri; Nakazato, Katsuharu; Shimonaka, Yoshiko; Hřebíčková, Martina; Kourilova, Sylvie; Yik, Michelle; Ficková, Emília; Brunner-Sciarra, Marina; de Figueora, Nora Leibovich; Schmidt, Vanina; Ahn, Chang-kyu; Ahn, Hyun-nie; Aguilar-Vafaie, Maria E.; Siuta, Jerzy; Szmigielska, Barbara; Cain, Thomas R.; Crawford, Jarret T.; Mastor, Khairul Anwar; Rolland, Jean-Pierre; Nansubuga, Florence; Miramontez, Daniel R.; Benet-Martínez, Veronica; Rossier, Jérôme; Bratko, Denis; Halberstadt, Jamin; Yamaguchi, Mami; Knežević, Goran; Martin, Thomas A.; Gheorghiu, Mirona; Smith, Peter B.; Barbaranelli, Claduio; Wang, Lei; Shakespeare-Finch, Jane; Lima, Margarida P.; Klinkosz, Waldemar; Sekowski, Andrzej; Alcalay, Lidia; Simonetti, Franco; Avdeyeva, Tatyana V.; Pramila, V. S.; Terracciano, Antonio

    2012-01-01

    Age trajectories for personality traits are known to be similar across cultures. To address whether stereotypes of age groups reflect these age-related changes in personality, we asked participants in 26 countries (N = 3,323) to rate typical adolescents, adults, and old persons in their own country. Raters across nations tended to share similar beliefs about different age groups; adolescents were seen as impulsive, rebellious, undisciplined, preferring excitement and novelty, whereas old people were consistently considered lower on impulsivity, activity, antagonism, and Openness. These consensual age group stereotypes correlated strongly with published age differences on the five major dimensions of personality and most of 30 specific traits, using as criteria of accuracy both self-reports and observer ratings, different survey methodologies, and data from up to 50 nations. However, personal stereotypes were considerably less accurate, and consensual stereotypes tended to exaggerate differences across age groups. PMID:23088227

  2. Accurate car plate detection via car face landmark localization

    Science.gov (United States)

    Li, Hailiang; Chiu, Man-Yau; Wu, Kangheng; Lei, Zhibin; Lam, Kin-Man

    2017-07-01

    For intelligent vehicle surveillance systems, it is a big challenge to detect small, blurred car plates of vehicles driving on a highway. In this paper, we present a novel, two-stage detection scheme for small, blurred car-plate detection in large surveillance images. Our proposed scheme firstly detects vehicles, and then locates the car plates in specific regions of detected vehicles based on our proposed car-face landmark localization algorithm. Our scheme can also solve the high false-alarming rate problem with small, blurred car-plate detection. Experimental results show that our proposed method is accurate, and able to reduce the false-alarming rate, without any compromise in speed.

  3. Can X-ray Observations Provide Accurate Pulsar Distances?

    Science.gov (United States)

    Roberts, Mallory; Bognar, K.; Chatterjee, S.

    2014-01-01

    X-ray observations are often used to estimate pulsar distances based on such things as the observed correlation between the spin down power and the X-ray luminosity, the fit value of the absorption, or thermal emission from an assumed surface area. However, none of these methods have been systematically tested against pulsars with accurately known distances. We will present initial results from a systematic analysis of archival X-ray data of pulsars which have well determined distances through parallax measurements. We will use these results to derive a new Lx-Edot relationship for both young and recycled pulsars, compare the measured nH to the Drimmel et al. (2003) 3D Galactic Extinction Model, and estimate the surface emission radii using both blackbody and neutron star atmosphere models.

  4. Machine Learning of Accurate Energy-Conserving Molecular Force Fields

    CERN Document Server

    Chmiela, Stefan; Sauceda, Huziel E; Poltavsky, Igor; Schütt, Kristof; Müller, Klaus-Robert

    2016-01-01

    Using conservation of energy -- a fundamental property of closed classical and quantum mechanical systems -- we develop an efficient gradient-domain machine learning (GDML) approach to construct accurate molecular force fields using a restricted number of samples from ab initio molecular dynamics (AIMD) trajectories. The GDML implementation is able to reproduce global potential-energy surfaces of intermediate-size molecules with an accuracy of 0.3 kcal/mol for energies and 1 kcal/mol/{\\AA} for atomic forces using only 1000 conformational geometries for training. We demonstrate this accuracy for AIMD trajectories of molecules, including benzene, toluene, naphthalene, ethanol, uracil, and aspirin. The challenge of constructing conservative force fields is accomplished in our work by learning in a Hilbert space of vector-valued functions that obey the law of energy conservation. The GDML approach enables quantitative molecular dynamics simulations for molecules at a fraction of cost of explicit AIMD calculations...

  5. Accurate evaluation and analysis of functional genomics data and methods

    Science.gov (United States)

    Greene, Casey S.; Troyanskaya, Olga G.

    2016-01-01

    The development of technology capable of inexpensively performing large-scale measurements of biological systems has generated a wealth of data. Integrative analysis of these data holds the promise of uncovering gene function, regulation, and, in the longer run, understanding complex disease. However, their analysis has proved very challenging, as it is difficult to quickly and effectively assess the relevance and accuracy of these data for individual biological questions. Here, we identify biases that present challenges for the assessment of functional genomics data and methods. We then discuss evaluation methods that, taken together, begin to address these issues. We also argue that the funding of systematic data-driven experiments and of high-quality curation efforts will further improve evaluation metrics so that they more-accurately assess functional genomics data and methods. Such metrics will allow researchers in the field of functional genomics to continue to answer important biological questions in a data-driven manner. PMID:22268703

  6. Composites by rapid prototyping technology

    CSIR Research Space (South Africa)

    Kumar, S

    2010-02-01

    Full Text Available powder is a fiber, problems of manufacturing occur. The method has also been used to make Metal Matrix Composite (MMC), e.g Fe and graphite [17], WC-Co [18,19], WC-Co and Cu [20,21], Fe, Ni and TiC [22] etc and Ceramic Matrix Composite (CMC) e.g. Si... of various materials used. Key words: : Rapid Prototyping (RP), Laser, Composites 1 Introduction Rapid Prototyping (RP) initially focussed on polymers. These were later re- placed/supplemented by ceramics, metals and composites. Composites are used in RP...

  7. Rapid onsite assessment of spore viability.

    Energy Technology Data Exchange (ETDEWEB)

    Branda, Steven; Lane, Todd W.; VanderNoot, Victoria A.; Gaucher, Sara P.; Jokerst, Amanda S.

    2005-12-01

    This one year LDRD addresses problems of threat assessment and restoration of facilities following a bioterror incident like the incident that closed down mail facilities in late 2001. Facilities that are contaminated with pathogenic spores such as B. anthracis spores must be shut down while they are treated with a sporicidal agent and the effectiveness of the treatment is ascertained. This process involves measuring the viability of spore test strips, laid out in a grid throughout the facility; the CDC accepted methodologies require transporting the samples to a laboratory and carrying out a 48 hr outgrowth experiment. We proposed developing a technique that will ultimately lead to a fieldable microfluidic device that can rapidly assess (ideally less than 30 min) spore viability and effectiveness of sporicidal treatment, returning facilities to use in hours not days. The proposed method will determine viability of spores by detecting early protein synthesis after chemical germination. During this year, we established the feasibility of this approach and gathered preliminary results that should fuel a future more comprehensive effort. Such a proposal is currently under review with the NIH. Proteomic signatures of Bacillus spores and vegetative cells were assessed by both slab gel electrophoresis as well as microchip based gel electrophoresis employing sensitive laser-induced fluorescence detection. The conditions for germination using a number of chemical germinants were evaluated and optimized and the time course of protein synthesis was ascertained. Microseparations were carried out using both viable spores and spores inactivated by two different methods. A select number of the early synthesis proteins were digested into peptides for analysis by mass spectrometry.

  8. Accurate fluid force measurement based on control surface integration

    Science.gov (United States)

    Lentink, David

    2018-01-01

    Nonintrusive 3D fluid force measurements are still challenging to conduct accurately for freely moving animals, vehicles, and deforming objects. Two techniques, 3D particle image velocimetry (PIV) and a new technique, the aerodynamic force platform (AFP), address this. Both rely on the control volume integral for momentum; whereas PIV requires numerical integration of flow fields, the AFP performs the integration mechanically based on rigid walls that form the control surface. The accuracy of both PIV and AFP measurements based on the control surface integration is thought to hinge on determining the unsteady body force associated with the acceleration of the volume of displaced fluid. Here, I introduce a set of non-dimensional error ratios to show which fluid and body parameters make the error negligible. The unsteady body force is insignificant in all conditions where the average density of the body is much greater than the density of the fluid, e.g., in gas. Whenever a strongly deforming body experiences significant buoyancy and acceleration, the error is significant. Remarkably, this error can be entirely corrected for with an exact factor provided that the body has a sufficiently homogenous density or acceleration distribution, which is common in liquids. The correction factor for omitting the unsteady body force, {{{ {ρ f}} {1 - {ρ f} ( {{ρ b}+{ρ f}} )}.{( {{{{ρ }}b}+{ρ f}} )}}} , depends only on the fluid, {ρ f}, and body, {{ρ }}b, density. Whereas these straightforward solutions work even at the liquid-gas interface in a significant number of cases, they do not work for generalized bodies undergoing buoyancy in combination with appreciable body density inhomogeneity, volume change (PIV), or volume rate-of-change (PIV and AFP). In these less common cases, the 3D body shape needs to be measured and resolved in time and space to estimate the unsteady body force. The analysis shows that accounting for the unsteady body force is straightforward to non

  9. Fast and accurate inference of local ancestry in Latino populations

    Science.gov (United States)

    Baran, Yael; Pasaniuc, Bogdan; Sankararaman, Sriram; Torgerson, Dara G.; Gignoux, Christopher; Eng, Celeste; Rodriguez-Cintron, William; Chapela, Rocio; Ford, Jean G.; Avila, Pedro C.; Rodriguez-Santana, Jose; Burchard, Esteban Gonzàlez; Halperin, Eran

    2012-01-01

    Motivation: It is becoming increasingly evident that the analysis of genotype data from recently admixed populations is providing important insights into medical genetics and population history. Such analyses have been used to identify novel disease loci, to understand recombination rate variation and to detect recent selection events. The utility of such studies crucially depends on accurate and unbiased estimation of the ancestry at every genomic locus in recently admixed populations. Although various methods have been proposed and shown to be extremely accurate in two-way admixtures (e.g. African Americans), only a few approaches have been proposed and thoroughly benchmarked on multi-way admixtures (e.g. Latino populations of the Americas). Results: To address these challenges we introduce here methods for local ancestry inference which leverage the structure of linkage disequilibrium in the ancestral population (LAMP-LD), and incorporate the constraint of Mendelian segregation when inferring local ancestry in nuclear family trios (LAMP-HAP). Our algorithms uniquely combine hidden Markov models (HMMs) of haplotype diversity within a novel window-based framework to achieve superior accuracy as compared with published methods. Further, unlike previous methods, the structure of our HMM does not depend on the number of reference haplotypes but on a fixed constant, and it is thereby capable of utilizing large datasets while remaining highly efficient and robust to over-fitting. Through simulations and analysis of real data from 489 nuclear trio families from the mainland US, Puerto Rico and Mexico, we demonstrate that our methods achieve superior accuracy compared with published methods for local ancestry inference in Latinos. Availability: http://lamp.icsi.berkeley.edu/lamp/lampld/ Contact: bpasaniu@hsph.harvard.edu Supplementary information: Supplementary data are available at Bioinformatics online. PMID:22495753

  10. Sleep Deprivation Impairs the Accurate Recognition of Human Emotions

    Science.gov (United States)

    van der Helm, Els; Gujar, Ninad; Walker, Matthew P.

    2010-01-01

    Study Objectives: Investigate the impact of sleep deprivation on the ability to recognize the intensity of human facial emotions. Design: Randomized total sleep-deprivation or sleep-rested conditions, involving between-group and within-group repeated measures analysis. Setting: Experimental laboratory study. Participants: Thirty-seven healthy participants, (21 females) aged 18–25 y, were randomly assigned to the sleep control (SC: n = 17) or total sleep deprivation group (TSD: n = 20). Interventions: Participants performed an emotional face recognition task, in which they evaluated 3 different affective face categories: Sad, Happy, and Angry, each ranging in a gradient from neutral to increasingly emotional. In the TSD group, the task was performed once under conditions of sleep deprivation, and twice under sleep-rested conditions following different durations of sleep recovery. In the SC group, the task was performed twice under sleep-rested conditions, controlling for repeatability. Measurements and Results: In the TSD group, when sleep-deprived, there was a marked and significant blunting in the recognition of Angry and Happy affective expressions in the moderate (but not extreme) emotional intensity range; differences that were most reliable and significant in female participants. No change in the recognition of Sad expressions was observed. These recognition deficits were, however, ameliorated following one night of recovery sleep. No changes in task performance were observed in the SC group. Conclusions: Sleep deprivation selectively impairs the accurate judgment of human facial emotions, especially threat relevant (Anger) and reward relevant (Happy) categories, an effect observed most significantly in females. Such findings suggest that sleep loss impairs discrete affective neural systems, disrupting the identification of salient affective social cues. Citation: van der Helm E; Gujar N; Walker MP. Sleep deprivation impairs the accurate recognition of human

  11. Coaxial visible and FIR camera system with accurate geometric calibration

    Science.gov (United States)

    Ogino, Yuka; Shibata, Takashi; Tanaka, Masayuki; Okutomi, Masatoshi

    2017-05-01

    A far-infrared (FIR) image contains important invisible information for various applications such as night vision and fire detection, while a visible image includes colors and textures in a scene. We present a coaxial visible and FIR camera system accompanied to obtain the complementary information of both images simultaneously. The proposed camera system is composed of three parts: a visible camera, a FIR camera, and a beam-splitter made from silicon. The FIR radiation from the scene is reflected at the beam-splitter, while the visible radiation is transmitted through this beam-splitter. Even if we use this coaxial visible and FIR camera system, the alignment between the visible and FIR images are not perfect. Therefore, we also present the joint calibration method which can simultaneously estimate accurate geometric parameters of both cameras, i.e. the intrinsic parameters of both cameras and the extrinsic parameters between both cameras. In the proposed calibration method, we use a novel calibration target which has a two-layer structure where thermal emission property of each layer is different. By using the proposed calibration target, we can stably and precisely obtain the corresponding points of the checker pattern in the calibration target from both the visible and the FIR images. Widely used calibration tools can accurately estimate both camera parameters. We can obtain aligned visible and FIR images by the coaxial camera system with precise calibration using two-layer calibration target. Experimental results demonstrate that the proposed camera system is useful for various applications such as image fusion, image denoising, and image up-sampling.

  12. An accurate and portable solid state neutron rem meter

    Energy Technology Data Exchange (ETDEWEB)

    Oakes, T.M. [Nuclear Science and Engineering Institute, University of Missouri, Columbia, MO (United States); Bellinger, S.L. [Department of Mechanical and Nuclear Engineering, Kansas State University, Manhattan, KS (United States); Miller, W.H. [Nuclear Science and Engineering Institute, University of Missouri, Columbia, MO (United States); Missouri University Research Reactor, Columbia, MO (United States); Myers, E.R. [Department of Physics, University of Missouri, Kansas City, MO (United States); Fronk, R.G.; Cooper, B.W [Department of Mechanical and Nuclear Engineering, Kansas State University, Manhattan, KS (United States); Sobering, T.J. [Electronics Design Laboratory, Kansas State University, KS (United States); Scott, P.R. [Department of Physics, University of Missouri, Kansas City, MO (United States); Ugorowski, P.; McGregor, D.S; Shultis, J.K. [Department of Mechanical and Nuclear Engineering, Kansas State University, Manhattan, KS (United States); Caruso, A.N., E-mail: carusoan@umkc.edu [Department of Physics, University of Missouri, Kansas City, MO (United States)

    2013-08-11

    Accurately resolving the ambient neutron dose equivalent spanning the thermal to 15 MeV energy range with a single configuration and lightweight instrument is desirable. This paper presents the design of a portable, high intrinsic efficiency, and accurate neutron rem meter whose energy-dependent response is electronically adjusted to a chosen neutron dose equivalent standard. The instrument may be classified as a moderating type neutron spectrometer, based on an adaptation to the classical Bonner sphere and position sensitive long counter, which, simultaneously counts thermalized neutrons by high thermal efficiency solid state neutron detectors. The use of multiple detectors and moderator arranged along an axis of symmetry (e.g., long axis of a cylinder) with known neutron-slowing properties allows for the construction of a linear combination of responses that approximate the ambient neutron dose equivalent. Variations on the detector configuration are investigated via Monte Carlo N-Particle simulations to minimize the total instrument mass while maintaining acceptable response accuracy—a dose error less than 15% for bare {sup 252}Cf, bare AmBe, an epi-thermal and mixed monoenergetic sources is found at less than 4.5 kg moderator mass in all studied cases. A comparison of the energy dependent dose equivalent response and resultant energy dependent dose equivalent error of the present dosimeter to commercially-available portable rem meters and the prior art are presented. Finally, the present design is assessed by comparison of the simulated output resulting from applications of several known neutron sources and dose rates.

  13. WGS accurately predicts antimicrobial resistance in Escherichia coli.

    Science.gov (United States)

    Tyson, Gregory H; McDermott, Patrick F; Li, Cong; Chen, Yuansha; Tadesse, Daniel A; Mukherjee, Sampa; Bodeis-Jones, Sonya; Kabera, Claudine; Gaines, Stuart A; Loneragan, Guy H; Edrington, Tom S; Torrence, Mary; Harhay, Dayna M; Zhao, Shaohua

    2015-10-01

    The objective of this study was to determine the effectiveness of WGS in identifying resistance genotypes of MDR Escherichia coli and whether these correlate with observed phenotypes. Seventy-six E. coli strains were isolated from farm cattle and measured for phenotypic resistance to 15 antimicrobials with the Sensititre(®) system. Isolates with resistance to at least four antimicrobials in three classes were selected for WGS using an Illumina MiSeq. Genotypic analysis was conducted with in-house Perl scripts using BLAST analysis to identify known genes and mutations associated with clinical resistance. Over 30 resistance genes and a number of resistance mutations were identified among the E. coli isolates. Resistance genotypes correlated with 97.8% specificity and 99.6% sensitivity to the identified phenotypes. The majority of discordant results were attributable to the aminoglycoside streptomycin, whereas there was a perfect genotype-phenotype correlation for most antibiotic classes such as tetracyclines, quinolones and phenicols. WGS also revealed information about rare resistance mechanisms, such as structural mutations in chromosomal copies of ampC conferring third-generation cephalosporin resistance. WGS can provide comprehensive resistance genotypes and is capable of accurately predicting resistance phenotypes, making it a valuable tool for surveillance. Moreover, the data presented here showing the ability to accurately predict resistance suggest that WGS may be used as a screening tool in selecting anti-infective therapy, especially as costs drop and methods improve. Published by Oxford University Press on behalf of the British Society for Antimicrobial Chemotherapy 2015. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  14. Practical Schemes for Accurate Forces in Quantum Monte Carlo.

    Science.gov (United States)

    Moroni, S; Saccani, S; Filippi, C

    2014-11-11

    While the computation of interatomic forces has become a well-established practice within variational Monte Carlo (VMC), the use of the more accurate Fixed-Node Diffusion Monte Carlo (DMC) method is still largely limited to the computation of total energies on structures obtained at a lower level of theory. Algorithms to compute exact DMC forces have been proposed in the past, and one such scheme is also put forward in this work, but remain rather impractical due to their high computational cost. As a practical route to DMC forces, we therefore revisit here an approximate method, originally developed in the context of correlated sampling and named here the Variational Drift-Diffusion (VD) approach. We thoroughly investigate its accuracy by checking the consistency between the approximate VD force and the derivative of the DMC potential energy surface for the SiH and C2 molecules and employ a wide range of wave functions optimized in VMC to assess its robustness against the choice of trial function. We find that, for all but the poorest wave function, the discrepancy between force and energy is very small over all interatomic distances, affecting the equilibrium bond length obtained with the VD forces by less than 0.004 au. Furthermore, when the VMC forces are approximate due to the use of a partially optimized wave function, the DMC forces have smaller errors and always lead to an equilibrium distance in better agreement with the experimental value. We also show that the cost of computing the VD forces is only slightly larger than the cost of calculating the DMC energy. Therefore, the VD approximation represents a robust and efficient approach to compute accurate DMC forces, superior to the VMC counterparts.

  15. Influence of pansharpening techniques in obtaining accurate vegetation thematic maps

    Science.gov (United States)

    Ibarrola-Ulzurrun, Edurne; Gonzalo-Martin, Consuelo; Marcello-Ruiz, Javier

    2016-10-01

    In last decades, there have been a decline in natural resources, becoming important to develop reliable methodologies for their management. The appearance of very high resolution sensors has offered a practical and cost-effective means for a good environmental management. In this context, improvements are needed for obtaining higher quality of the information available in order to get reliable classified images. Thus, pansharpening enhances the spatial resolution of the multispectral band by incorporating information from the panchromatic image. The main goal in the study is to implement pixel and object-based classification techniques applied to the fused imagery using different pansharpening algorithms and the evaluation of thematic maps generated that serve to obtain accurate information for the conservation of natural resources. A vulnerable heterogenic ecosystem from Canary Islands (Spain) was chosen, Teide National Park, and Worldview-2 high resolution imagery was employed. The classes considered of interest were set by the National Park conservation managers. 7 pansharpening techniques (GS, FIHS, HCS, MTF based, Wavelet `à trous' and Weighted Wavelet `à trous' through Fractal Dimension Maps) were chosen in order to improve the data quality with the goal to analyze the vegetation classes. Next, different classification algorithms were applied at pixel-based and object-based approach, moreover, an accuracy assessment of the different thematic maps obtained were performed. The highest classification accuracy was obtained applying Support Vector Machine classifier at object-based approach in the Weighted Wavelet `à trous' through Fractal Dimension Maps fused image. Finally, highlight the difficulty of the classification in Teide ecosystem due to the heterogeneity and the small size of the species. Thus, it is important to obtain accurate thematic maps for further studies in the management and conservation of natural resources.

  16. Electron Microprobe Analysis Techniques for Accurate Measurements of Apatite

    Science.gov (United States)

    Goldoff, B. A.; Webster, J. D.; Harlov, D. E.

    2010-12-01

    Apatite [Ca5(PO4)3(F, Cl, OH)] is a ubiquitous accessory mineral in igneous, metamorphic, and sedimentary rocks. The mineral contains halogens and hydroxyl ions, which can provide important constraints on fugacities of volatile components in fluids and other phases in igneous and metamorphic environments in which apatite has equilibrated. Accurate measurements of these components in apatite are therefore necessary. Analyzing apatite by electron microprobe (EMPA), which is a commonly used geochemical analytical technique, has often been found to be problematic and previous studies have identified sources of error. For example, Stormer et al. (1993) demonstrated that the orientation of an apatite grain relative to the incident electron beam could significantly affect the concentration results. In this study, a variety of alternative EMPA operating conditions for apatite analysis were investigated: a range of electron beam settings, count times, crystal grain orientations, and calibration standards were tested. Twenty synthetic anhydrous apatite samples that span the fluorapatite-chlorapatite solid solution series, and whose halogen concentrations were determined by wet chemistry, were analyzed. Accurate measurements of these samples were obtained with many EMPA techniques. One effective method includes setting a static electron beam to 10-15nA, 15kV, and 10 microns in diameter. Additionally, the apatite sample is oriented with the crystal’s c-axis parallel to the slide surface and the count times are moderate. Importantly, the F and Cl EMPA concentrations are in extremely good agreement with the wet-chemical data. We also present EMPA operating conditions and techniques that are problematic and should be avoided. J.C. Stormer, Jr. et al., Am. Mineral. 78 (1993) 641-648.

  17. Accurate molecular classification of cancer using simple rules

    Directory of Open Access Journals (Sweden)

    Gotoh Osamu

    2009-10-01

    Full Text Available Abstract Background One intractable problem with using microarray data analysis for cancer classification is how to reduce the extremely high-dimensionality gene feature data to remove the effects of noise. Feature selection is often used to address this problem by selecting informative genes from among thousands or tens of thousands of genes. However, most of the existing methods of microarray-based cancer classification utilize too many genes to achieve accurate classification, which often hampers the interpretability of the models. For a better understanding of the classification results, it is desirable to develop simpler rule-based models with as few marker genes as possible. Methods We screened a small number of informative single genes and gene pairs on the basis of their depended degrees proposed in rough sets. Applying the decision rules induced by the selected genes or gene pairs, we constructed cancer classifiers. We tested the efficacy of the classifiers by leave-one-out cross-validation (LOOCV of training sets and classification of independent test sets. Results We applied our methods to five cancerous gene expression datasets: leukemia (acute lymphoblastic leukemia [ALL] vs. acute myeloid leukemia [AML], lung cancer, prostate cancer, breast cancer, and leukemia (ALL vs. mixed-lineage leukemia [MLL] vs. AML. Accurate classification outcomes were obtained by utilizing just one or two genes. Some genes that correlated closely with the pathogenesis of relevant cancers were identified. In terms of both classification performance and algorithm simplicity, our approach outperformed or at least matched existing methods. Conclusion In cancerous gene expression datasets, a small number of genes, even one or two if selected correctly, is capable of achieving an ideal cancer classification effect. This finding also means that very simple rules may perform well for cancerous class prediction.

  18. Rapid detoxification from opioid dependence under general anaesthesia versus standard methadone tapering: abstinence rates and withdrawal distress experiences.

    NARCIS (Netherlands)

    Krabbe, P.F.M.; Koning, J.P.; Heinen, N.; Laheij, R.J.F.; Cauter, R.M.V. van; Jong, C.A.J. de

    2003-01-01

    The aim of this work was to study abstinence rates and withdrawal effects of rapid detoxification of opioid-dependents under general anaesthesia (RD-GA) compared to standard methadone tapering (SMT) using a prospective clinical trial with a follow-up of 3 months, as a preliminary study at the

  19. HomeSpace:Maputo Dwelling Processes in ten Rapidly Expanding Peri-Urban Areas of an African City

    DEFF Research Database (Denmark)

    Eskemose Andersen, Jørgen; Sollien, Silje Erøy; Costa, Ana Bénard da

    2013-01-01

    This chapter deals with key concepts and preliminary findings of the ressearch programme "Home Space-Meanings and perceptions of the built envioment in Peri-urban Maputo, Mozambique." The Programme examines the nature of emerging forms of "urbanism as a way of Life" in a rapidly urbanizing African...

  20. Rapid detoxification from opioid dependence under general anaesthesia versus standard methadone tapering : abstinence rates and withdrawal distress experiences

    NARCIS (Netherlands)

    Krabbe, Paul F M; Koning, Jeroen P F; Heinen, Nadia; Laheij, Robert J F; van Cauter, R M Victory; De Jong, Cor A J

    The aim of this work was to study abstinence rates and withdrawal effects of rapid detoxification of opioid-dependents under general anaesthesia (RD-GA) compared to standard methadone tapering (SMT) using a prospective clinical trial with a follow-up of 3 months, as a preliminary study at the

  1. Performance of commercial platforms for rapid genotyping of polymorphisms affecting warfarin dose.

    Science.gov (United States)

    King, Cristi R; Porche-Sorbet, Rhonda M; Gage, Brian F; Ridker, Paul M; Renaud, Yannick; Phillips, Michael S; Eby, Charles

    2008-06-01

    Initiation of warfarin therapy is associated with bleeding owing to its narrow therapeutic window and unpredictable therapeutic dose. Pharmacogenetic-based dosing algorithms can improve accuracy of initial warfarin dosing but require rapid genotyping for cytochrome P-450 2C9 (CYP2C9) *2 and *3 single nucleotide polymorphisms (SNPs) and a vitamin K epoxide reductase (VKORC1) SNP. We evaluated 4 commercial systems: INFINITI analyzer (AutoGenomics, Carlsbad, CA), Invader assay (Third Wave Technologies, Madison, WI), Tag-It Mutation Detection assay (Luminex Molecular Diagnostics, formerly Tm Bioscience, Toronto, Canada), and Pyrosequencing (Biotage, Uppsala, Sweden). We genotyped 112 DNA samples and resolved any discrepancies with bidirectional sequencing. The INFINITI analyzer was 100% accurate for all SNPs and required 8 hours. Invader and Tag-It were 100% accurate for CYP2C9 SNPs, 99% accurate for VKORC1 -1639/3673 SNP, and required 3 hours and 8 hours, respectively. Pyrosequencing was 99% accurate for CYP2C9 *2, 100% accurate for CYP2C9 *3, and 100% accurate for VKORC1 and required 4 hours. Current commercial platforms provide accurate and rapid genotypes for pharmacogenetic dosing during initiation of warfarin therapy.

  2. Seismogeodesy for rapid earthquake and tsunami characterization

    Science.gov (United States)

    Bock, Y.

    2016-12-01

    Rapid estimation of earthquake magnitude and fault mechanism is critical for earthquake and tsunami warning systems. Traditionally, the monitoring of earthquakes and tsunamis has been based on seismic networks for estimating earthquake magnitude and slip, and tide gauges and deep-ocean buoys for direct measurement of tsunami waves. These methods are well developed for ocean basin-wide warnings but are not timely enough to protect vulnerable populations and infrastructure from the effects of local tsunamis, where waves may arrive within 15-30 minutes of earthquake onset time. Direct measurements of displacements by GPS networks at subduction zones allow for rapid magnitude and slip estimation in the near-source region, that are not affected by instrumental limitations and magnitude saturation experienced by local seismic networks. However, GPS displacements by themselves are too noisy for strict earthquake early warning (P-wave detection). Optimally combining high-rate GPS and seismic data (in particular, accelerometers that do not clip), referred to as seismogeodesy, provides a broadband instrument that does not clip in the near field, is impervious to magnitude saturation, and provides accurate real-time static and dynamic displacements and velocities in real time. Here we describe a NASA-funded effort to integrate GPS and seismogeodetic observations as part of NOAA's Tsunami Warning Centers in Alaska and Hawaii. It consists of a series of plug-in modules that allow for a hierarchy of rapid seismogeodetic products, including automatic P-wave picking, hypocenter estimation, S-wave prediction, magnitude scaling relationships based on P-wave amplitude (Pd) and peak ground displacement (PGD), finite-source CMT solutions and fault slip models as input for tsunami warnings and models. For the NOAA/NASA project, the modules are being integrated into an existing USGS Earthworm environment, currently limited to traditional seismic data. We are focused on a network of

  3. Rapid prototyping and stereolithography in dentistry.

    Science.gov (United States)

    Nayar, Sanjna; Bhuminathan, S; Bhat, Wasim Manzoor

    2015-04-01

    The word rapid prototyping (RP) was first used in mechanical engineering field in the early 1980s to describe the act of producing a prototype, a unique product, the first product, or a reference model. In the past, prototypes were handmade by sculpting or casting, and their fabrication demanded a long time. Any and every prototype should undergo evaluation, correction of defects, and approval before the beginning of its mass or large scale production. Prototypes may also be used for specific or restricted purposes, in which case they are usually called a preseries model. With the development of information technology, three-dimensional models can be devised and built based on virtual prototypes. Computers can now be used to create accurately detailed projects that can be assessed from different perspectives in a process known as computer aided design (CAD). To materialize virtual objects using CAD, a computer aided manufacture (CAM) process has been developed. To transform a virtual file into a real object, CAM operates using a machine connected to a computer, similar to a printer or peripheral device. In 1987, Brix and Lambrecht used, for the first time, a prototype in health care. It was a three-dimensional model manufactured using a computer numerical control device, a type of machine that was the predecessor of RP. In 1991, human anatomy models produced with a technology called stereolithography were first used in a maxillofacial surgery clinic in Viena.

  4. Rapid prototyping and stereolithography in dentistry

    Directory of Open Access Journals (Sweden)

    Sanjna Nayar

    2015-01-01

    Full Text Available The word rapid prototyping (RP was first used in mechanical engineering field in the early 1980s to describe the act of producing a prototype, a unique product, the first product, or a reference model. In the past, prototypes were handmade by sculpting or casting, and their fabrication demanded a long time. Any and every prototype should undergo evaluation, correction of defects, and approval before the beginning of its mass or large scale production. Prototypes may also be used for specific or restricted purposes, in which case they are usually called a preseries model. With the development of information technology, three-dimensional models can be devised and built based on virtual prototypes. Computers can now be used to create accurately detailed projects that can be assessed from different perspectives in a process known as computer aided design (CAD. To materialize virtual objects using CAD, a computer aided manufacture (CAM process has been developed. To transform a virtual file into a real object, CAM operates using a machine connected to a computer, similar to a printer or peripheral device. In 1987, Brix and Lambrecht used, for the first time, a prototype in health care. It was a three-dimensional model manufactured using a computer numerical control device, a type of machine that was the predecessor of RP. In 1991, human anatomy models produced with a technology called stereolithography were first used in a maxillofacial surgery clinic in Viena.

  5. RRTM: A rapid radiative transfer model

    Energy Technology Data Exchange (ETDEWEB)

    Mlawer, E.J.; Taubman, S.J.; Clough, S.A. [Atmospheric and Environmental Research, Inc., Cambridge, MA (United States)

    1996-04-01

    A rapid radiative transfer model (RRTM) for the calculation of longwave clear-sky fluxes and cooling rates has been developed. The model, which uses the correlated-k method, is both accurate and computationally fast. The foundation for RRTM is the line-by-line radiative transfer model (LBLRTM) from which the relevant k-distributions are obtained. LBLRTM, which has been extensively validated against spectral observations e.g., the high-resolution sounder and the Atmospheric Emitted Radiance Interferometer, is used to validate the flux and cooling rate results from RRTM. Validations of RRTM`s results have been performed for the tropical, midlatitude summer, and midlatitude winter atmospheres, as well as for the four Intercomparison of Radiation Codes in Climate Models (ICRCCM) cases from the Spectral Radiance Experiment (SPECTRE). Details of some of these validations are presented below. RRTM has the identical atmospheric input module as LBLRTM, facilitating intercomparisons with LBLRTM and application of the model at the Atmospheric Radiation Measurement Cloud and Radiation Testbed sites.

  6. Accurate measurement of absolute experimental inelastic mean free paths and EELS differential cross-sections

    Energy Technology Data Exchange (ETDEWEB)

    Craven, Alan J.; Bobynko, Joanna; Sala, Bianca; MacLaren, Ian, E-mail: ian.maclaren@glasgow.ac.uk

    2016-11-15

    Methods are described for measuring accurate absolute experimental inelastic mean free paths and differential cross-sections using DualEELS. The methods remove the effects of surface layers and give the results for the bulk materials. The materials used are VC{sub 0.83}, TiC{sub 0.98}, VN{sub 0.97} and TiN{sub 0.88} but the method should be applicable to a wide range of materials. The data was taken at 200 keV using a probe half angle of 29 mrad and a collection angle of 36 mrad. The background can be subtracted from under the ionisation edges, which can then be separated from each other. This is achieved by scaling Hartree-Slater calculated cross-sections to the edges in the atomic regions well above the threshold. The average scaling factors required are 1.00 for the non-metal K-edges and 1.01 for the metal L-edges (with uncertainties of a few percent). If preliminary measurements of the chromatic effects in the post-specimen lenses are correct, both drop to 0.99. The inelastic mean free path for TiC{sub 0.98} was measured as 103.6±0.5 nm compared to the prediction of 126.9 nm based on the widely used Iakoubovskii parameterisation. - Highlights: • We show how to extract absolute cross sections for EELS edges using DualEELS. • The method removes the effects of any surface layers on standards. • We use a needle specimen to determining the mean free path for inelastic scattering. • Constrained background fitting is essential to correct background subtraction. • Absolute cross sections are determined for TiC, TiN, VC and VN.

  7. Combining angular differential imaging and accurate polarimetry with SPHERE/IRDIS to characterize young giant exoplanets

    Science.gov (United States)

    van Holstein, Rob G.; Snik, Frans; Girard, Julien H.; de Boer, Jozua; Ginski, C.; Keller, Christoph U.; Stam, Daphne M.; Beuzit, Jean-Luc; Mouillet, David; Kasper, Markus; Langlois, Maud; Zurlo, Alice; de Kok, Remco J.; Vigan, Arthur

    2017-09-01

    Young giant exoplanets emit infrared radiation that can be linearly polarized up to several percent. This linear polarization can trace: 1) the presence of atmospheric cloud and haze layers, 2) spatial structure, e.g. cloud bands and rotational flattening, 3) the spin axis orientation and 4) particle sizes and cloud top pressure. We introduce a novel high-contrast imaging scheme that combines angular differential imaging (ADI) and accurate near-infrared polarimetry to characterize self-luminous giant exoplanets. We implemented this technique at VLT/SPHEREIRDIS and developed the corresponding observing strategies, the polarization calibration and the data-reduction approaches. The combination of ADI and polarimetry is challenging, because the field rotation required for ADI negatively affects the polarimetric performance. By combining ADI and polarimetry we can characterize planets that can be directly imaged with a very high signal-to-noise ratio. We use the IRDIS pupil-tracking mode and combine ADI and principal component analysis to reduce speckle noise. We take advantage of IRDIS' dual-beam polarimetric mode to eliminate differential effects that severely limit the polarimetric sensitivity (flat-fielding errors, differential aberrations and seeing), and thus further suppress speckle noise. To correct for instrumental polarization effects, we apply a detailed Mueller matrix model that describes the telescope and instrument and that has an absolute polarimetric accuracy analysis. We estimate preliminary 1σ upper limits on the degree of linear polarization of ˜ 1% and ˜ 0.1% for the planets of HR 8799 and PZ Tel B, respectively. The achieved sub-percent sensitivity and accuracy show that our technique has great promise for characterizing exoplanets through direct-imaging polarimetry

  8. Rapid, Reliable Shape Setting of Superelastic Nitinol for Prototyping Robots.

    Science.gov (United States)

    Gilbert, Hunter B; Webster, Robert J

    Shape setting Nitinol tubes and wires in a typical laboratory setting for use in superelastic robots is challenging. Obtaining samples that remain superelastic and exhibit desired precurvatures currently requires many iterations, which is time consuming and consumes a substantial amount of Nitinol. To provide a more accurate and reliable method of shape setting, in this paper we propose an electrical technique that uses Joule heating to attain the necessary shape setting temperatures. The resulting high power heating prevents unintended aging of the material and yields consistent and accurate results for the rapid creation of prototypes. We present a complete algorithm and system together with an experimental analysis of temperature regulation. We experimentally validate the approach on Nitinol tubes that are shape set into planar curves. We also demonstrate the feasibility of creating general space curves by shape setting a helical tube. The system demonstrates a mean absolute temperature error of 10°C.

  9. Developmental evolution facilitates rapid adaptation.

    Science.gov (United States)

    Lin, Hui; Kazlauskas, Romas J; Travisano, Michael

    2017-11-21

    Developmental evolution has frequently been identified as a mode for rapid adaptation, but direct observations of the selective benefits and associated mechanisms of developmental evolution are necessarily challenging to obtain. Here we show rapid evolution of greatly increased rates of dispersal by developmental changes when populations experience stringent selection. Replicate populations of the filamentous fungus Trichoderma citrinoviride underwent 85 serial transfers, under conditions initially favoring growth but not dispersal. T. citrinoviride populations shifted away from multicellular growth toward increased dispersal by producing one thousand times more single-celled asexual conidial spores, three times sooner than the ancestral genotype. Conidia of selected lines also germinated fifty percent faster. Gene expression changed substantially between the ancestral and selected fungi, especially for spore production and growth, demonstrating rapid evolution of tight regulatory control for down-regulation of growth and up-regulation of conidia production between 18 and 24 hours of growth. These changes involved both developmentally fixed and plastic changes in gene expression, showing that complex developmental changes can serve as a mechanism for rapid adaptation.

  10. Multigrade Teaching Rapid Appraisal Procedure.

    Science.gov (United States)

    Nielsen, Dean

    Multigrade classes have been recognized as part of elementary education for many years, but their special needs have been largely ignored. This manual focuses on the survey research that should predate the design of instructional management strategies in multigrade classrooms. It describes rapid and reliable ways to collect information about the…

  11. Rapid thermal processing of semiconductors

    CERN Document Server

    Borisenko, Victor E

    1997-01-01

    Rapid thermal processing has contributed to the development of single wafer cluster processing tools and other innovations in integrated circuit manufacturing environments Borisenko and Hesketh review theoretical and experimental progress in the field, discussing a wide range of materials, processes, and conditions They thoroughly cover the work of international investigators in the field

  12. Furnace for rapid thermal processing

    NARCIS (Netherlands)

    Roozeboom, F.; Duine, P.A.; Sluis, P. van der

    2001-01-01

    A Method (1) for Rapid Thermal Processing of a wafer (7), wherein the wafer (7) is heated by lamps (9), and the heat radiation is reflected by an optical switching device (15,17) which is in the reflecting state during the heating stage. During the cooling stage of the wafer (7), the heat is

  13. Rapid Energy Modeling Workflow Demonstration

    Science.gov (United States)

    2013-10-31

    BIM Building Information Modeling BPA Building Performance Analysis BTU British Thermal Unit CBECS Commercial Building ...geometry, orientation, weather, and materials, generates 3D Building Information Models ( BIM ) guided by satellite views of building footprints and...Rapid Energy Modeling (REM) workflows that employed building information modeling ( BIM ) approaches and conceptual energy analysis.

  14. Portable Diagnostics and Rapid Germination

    Energy Technology Data Exchange (ETDEWEB)

    Dunn, Zachary Spencer [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-12-01

    In the Bioenergy and Defense Department of Sandia National Laboratories, characterization of the BaDx (Bacillus anthracis diagnostic cartridge) was performed and rapid germination chemistry was investigated. BaDx was tested with complex sample matrixes inoculated with Bacillus anthracis, and the trials proved that BaDx will detect Bacillus anthracis in a variety of the medium, such as dirt, serum, blood, milk, and horse fluids. The dimensions of the device were altered to accommodate an E. coli or Listeria lateral flow immunoassay, and using a laser printer, BaDx devices were manufactured to identify E. coli and Listeria. Initial testing with E. coli versions of BaDx indicate that the device will be viable as a portable diagnostic cartridge. The device would be more effective with faster bacteria germination; hence studies were performed the use of rapid germination chemistry. Trials with calcium dipicolinic acid displayed increased cell germination, as shown by control studies using a microplate reader. Upon lyophilization the rapid germination chemistry failed to change growth patterns, indicating that the calcium dipicolinic acid was not solubilized under the conditions tested. Although incompatible with the portable diagnostic device, the experiments proved that the rapid germination chemistry was effective in increasing cell germination.

  15. An accurate Rb density measurement method for a plasma wakefield accelerator experiment using a novel Rb reservoir

    Energy Technology Data Exchange (ETDEWEB)

    Öz, E.; Batsch, F.; Muggli, P.

    2016-09-01

    A method to accurately measure the density of Rb vapor is described. We plan on using this method for the Advanced Wakefield (AWAKE) (Assmann et al., 2014 [1]) project at CERN , which will be the world's first proton driven plasma wakefield experiment. The method is similar to the hook (Marlow, 1967 [2]) method and has been described in great detail in the work by Hill et al. (1986) [3]. In this method a cosine fit is applied to the interferogram to obtain a relative accuracy on the order of 1% for the vapor density–length product. A single-mode, fiber-based, Mach–Zenhder interferometer will be built and used near the ends of the 10 meter-long AWAKE plasma source to be able to make accurate relative density measurement between these two locations. This can then be used to infer the vapor density gradient along the AWAKE plasma source and also change it to the value desired for the plasma wakefield experiment. Here we describe the plan in detail and show preliminary results obtained using a prototype 8 cm long novel Rb vapor cell.

  16. SIMS: a hybrid method for rapid conformational analysis.

    Directory of Open Access Journals (Sweden)

    Bryant Gipson

    Full Text Available Proteins are at the root of many biological functions, often performing complex tasks as the result of large changes in their structure. Describing the exact details of these conformational changes, however, remains a central challenge for computational biology due the enormous computational requirements of the problem. This has engendered the development of a rich variety of useful methods designed to answer specific questions at different levels of spatial, temporal, and energetic resolution. These methods fall largely into two classes: physically accurate, but computationally demanding methods and fast, approximate methods. We introduce here a new hybrid modeling tool, the Structured Intuitive Move Selector (sims, designed to bridge the divide between these two classes, while allowing the benefits of both to be seamlessly integrated into a single framework. This is achieved by applying a modern motion planning algorithm, borrowed from the field of robotics, in tandem with a well-established protein modeling library. sims can combine precise energy calculations with approximate or specialized conformational sampling routines to produce rapid, yet accurate, analysis of the large-scale conformational variability of protein systems. Several key advancements are shown, including the abstract use of generically defined moves (conformational sampling methods and an expansive probabilistic conformational exploration. We present three example problems that sims is applied to and demonstrate a rapid solution for each. These include the automatic determination of "active" residues for the hinge-based system Cyanovirin-N, exploring conformational changes involving long-range coordinated motion between non-sequential residues in Ribose-Binding Protein, and the rapid discovery of a transient conformational state of Maltose-Binding Protein, previously only determined by Molecular Dynamics. For all cases we provide energetic validations using well

  17. Rapid, low-cost prototyping of centrifugal microfluidic devices for effective implementation of various microfluidic components

    Directory of Open Access Journals (Sweden)

    Smith, Suzanne

    2015-05-01

    Full Text Available A centrifugal microfluidic platform to develop various microfluidic operations – the first of its kind in South Africa – is presented. Rapid and low-cost prototyping of centrifugal microfluidic disc devices, as well as a set-up to test the devices using centrifugal forces, is described. Preliminary results show that various microfluidic operations such as fluidic valving, transportation, and microfluidic droplet generation can be achieved. This work provides a complete centrifugal microfluidic platform and the building blocks on which to develop a variety of microfluidic applications and potential products rapidly and at a low cost.

  18. Accurate and interpretable nanoSAR models from genetic programming-based decision tree construction approaches.

    Science.gov (United States)

    Oksel, Ceyda; Winkler, David A; Ma, Cai Y; Wilkins, Terry; Wang, Xue Z

    2016-09-01

    The number of engineered nanomaterials (ENMs) being exploited commercially is growing rapidly, due to the novel properties they exhibit. Clearly, it is important to understand and minimize any risks to health or the environment posed by the presence of ENMs. Data-driven models that decode the relationships between the biological activities of ENMs and their physicochemical characteristics provide an attractive means of maximizing the value of scarce and expensive experimental data. Although such structure-activity relationship (SAR) methods have become very useful tools for modelling nanotoxicity endpoints (nanoSAR), they have limited robustness and predictivity and, most importantly, interpretation of the models they generate is often very difficult. New computational modelling tools or new ways of using existing tools are required to model the relatively sparse and sometimes lower quality data on the biological effects of ENMs. The most commonly used SAR modelling methods work best with large datasets, are not particularly good at feature selection, can be relatively opaque to interpretation, and may not account for nonlinearity in the structure-property relationships. To overcome these limitations, we describe the application of a novel algorithm, a genetic programming-based decision tree construction tool (GPTree) to nanoSAR modelling. We demonstrate the use of GPTree in the construction of accurate and interpretable nanoSAR models by applying it to four diverse literature datasets. We describe the algorithm and compare model results across the four studies. We show that GPTree generates models with accuracies equivalent to or superior to those of prior modelling studies on the same datasets. GPTree is a robust, automatic method for generation of accurate nanoSAR models with important advantages that it works with small datasets, automatically selects descriptors, and provides significantly improved interpretability of models.

  19. Integrated Translatome and Proteome: Approach for Accurate Portraying of Widespread Multifunctional Aspects of Trichoderma

    Science.gov (United States)

    Sharma, Vivek; Salwan, Richa; Sharma, P. N.; Gulati, Arvind

    2017-01-01

    Genome-wide studies of transcripts expression help in systematic monitoring of genes and allow targeting of candidate genes for future research. In contrast to relatively stable genomic data, the expression of genes is dynamic and regulated both at time and space level at different level in. The variation in the rate of translation is specific for each protein. Both the inherent nature of an mRNA molecule to be translated and the external environmental stimuli can affect the efficiency of the translation process. In biocontrol agents (BCAs), the molecular response at translational level may represents noise-like response of absolute transcript level and an adaptive response to physiological and pathological situations representing subset of mRNAs population actively translated in a cell. The molecular responses of biocontrol are complex and involve multistage regulation of number of genes. The use of high-throughput techniques has led to rapid increase in volume of transcriptomics data of Trichoderma. In general, almost half of the variations of transcriptome and protein level are due to translational control. Thus, studies are required to integrate raw information from different “omics” approaches for accurate depiction of translational response of BCAs in interaction with plants and plant pathogens. The studies on translational status of only active mRNAs bridging with proteome data will help in accurate characterization of only a subset of mRNAs actively engaged in translation. This review highlights the associated bottlenecks and use of state-of-the-art procedures in addressing the gap to accelerate future accomplishment of biocontrol mechanisms. PMID:28900417

  20. Can Triage Nurses Accurately Predict Patient Dispositions in the Emergency Department?

    Science.gov (United States)

    Alexander, Danette; Abbott, Lincoln; Zhou, Qiuping; Staff, Ilene

    2016-11-01

    Contemporary emergency departments experience crowded conditions with poor patient outcomes. If triage nurses could accurately predict admission, one theoretical intervention to reduce crowding is to place patients in the admission cue on arrival to the emergency department. The purpose of this study was to determine if triage nurses could accurately predict patient dispositions. This prospective study was conducted in a tertiary academic hospital's emergency department using a data collection tool embedded in the ED electronic information system. Study variables included the predicted and actual disposition, as well as level of care, gender, age, and Emergency Severity Index level. Data were collected for 28 consecutive days from September 17 through October 9, 2013. Sensitivity and specificity, positive and negative predictive values, and accuracy of prediction, as well as the associations between patient characteristics and nurse prediction, were calculated. A total of 5,135 cases were included in the analysis. The triage nurses predicted admissions with a sensitivity of 71.5% and discharges with a specificity of 88.0%. Accuracy was significantly higher for younger patients and for patients at very low or very high severity levels. Although the ability to predict admissions at triage by nurses was not adequate to support a change in the bed procurement process, a specificity of 88.0% could have implications for rapid ED discharges or other low-acuity processes designed within the emergency department. Further studies in additional settings and on alternative interventions are needed. Copyright © 2016 Emergency Nurses Association. Published by Elsevier Inc. All rights reserved.

  1. FragBag, an accurate representation of protein structure, retrieves structural neighbors from the entire PDB quickly and accurately.

    Science.gov (United States)

    Budowski-Tal, Inbal; Nov, Yuval; Kolodny, Rachel

    2010-02-23

    Fast identification of protein structures that are similar to a specified query structure in the entire Protein Data Bank (PDB) is fundamental in structure and function prediction. We present FragBag: An ultrafast and accurate method for comparing protein structures. We describe a protein structure by the collection of its overlapping short contiguous backbone segments, and discretize this set using a library of fragments. Then, we succinctly represent the protein as a "bags-of-fragments"-a vector that counts the number of occurrences of each fragment-and measure the similarity between two structures by the similarity between their vectors. Our representation has two additional benefits: (i) it can be used to construct an inverted index, for implementing a fast structural search engine of the entire PDB, and (ii) one can specify a structure as a collection of substructures, without combining them into a single structure; this is valuable for structure prediction, when there are reliable predictions only of parts of the protein. We use receiver operating characteristic curve analysis to quantify the success of FragBag in identifying neighbor candidate sets in a dataset of over 2,900 structures. The gold standard is the set of neighbors found by six state of the art structural aligners. Our best FragBag library finds more accurate candidate sets than the three other filter methods: The SGM, PRIDE, and a method by Zotenko et al. More interestingly, FragBag performs on a par with the computationally expensive, yet highly trusted structural aligners STRUCTAL and CE.

  2. Investigating rapid eye movement sleep without atonia in Parkinson's disease using the rapid eye movement sleep behavior disorder screening questionnaire.

    Science.gov (United States)

    Bolitho, Samuel J; Naismith, Sharon L; Terpening, Zoe; Grunstein, Ron R; Melehan, Kerri; Yee, Brendon J; Coeytaux, Alessandra; Gilat, Moran; Lewis, Simon J G

    2014-05-01

    Rapid eye movement (REM) sleep behavior disorder (RBD) is frequently observed in patients with Parkinson's disease (PD). Accurate diagnosis is essential for managing this condition. Furthermore, the emergence of idiopathic RBD in later life can represent a premotor feature, heralding the development of PD. Reliable, accurate methods for identifying RBD may offer a window for early intervention. This study sought to identify whether the RBD screening questionnaire (RBDSQ) and three questionnaires focused on dream enactment were able to correctly identify patients with REM without atonia (RWA), the neurophysiological hallmark of RBD. Forty-six patients with PD underwent neurological and sleep assessment in addition to completing the RBDSQ, the RBD single question (RBD1Q), and the Mayo Sleep Questionnaire (MSQ). The REM atonia index was derived for all participants as an objective measure of RWA. Patients identified to be RBD positive on the RBDSQ did not show increased RWA on polysomnography (80% sensitivity and 55% specificity). However, patients positive for RBD on questionnaires specific to dream enactment correctly identified higher degrees of RWA and improved the diagnostic accuracy of these questionnaires. This study suggests that the RBDSQ does not accurately identify RWA, essential for diagnosing RBD in PD. Furthermore, the results suggest that self-report measures of RBD need to focus questions on dream enactment behavior to better identify RWA and RBD. Further studies are needed to develop accurate determination and quantification of RWA in RBD to improve management of patients with PD in the future. © 2014 International Parkinson and Movement Disorder Society.

  3. Approaches for the accurate definition of geological time boundaries

    Science.gov (United States)

    Schaltegger, Urs; Baresel, Björn; Ovtcharova, Maria; Goudemand, Nicolas; Bucher, Hugo

    2015-04-01

    Which strategies lead to the most precise and accurate date of a given geological boundary? Geological units are usually defined by the occurrence of characteristic taxa and hence boundaries between these geological units correspond to dramatic faunal and/or floral turnovers and they are primarily defined using first or last occurrences of index species, or ideally by the separation interval between two consecutive, characteristic associations of fossil taxa. These boundaries need to be defined in a way that enables their worldwide recognition and correlation across different stratigraphic successions, using tools as different as bio-, magneto-, and chemo-stratigraphy, and astrochronology. Sedimentary sequences can be dated in numerical terms by applying high-precision chemical-abrasion, isotope-dilution, thermal-ionization mass spectrometry (CA-ID-TIMS) U-Pb age determination to zircon (ZrSiO4) in intercalated volcanic ashes. But, though volcanic activity is common in geological history, ashes are not necessarily close to the boundary we would like to date precisely and accurately. In addition, U-Pb zircon data sets may be very complex and difficult to interpret in terms of the age of ash deposition. To overcome these difficulties we use a multi-proxy approach we applied to the precise and accurate dating of the Permo-Triassic and Early-Middle Triassic boundaries in South China. a) Dense sampling of ashes across the critical time interval and a sufficiently large number of analysed zircons per ash sample can guarantee the recognition of all system complexities. Geochronological datasets from U-Pb dating of volcanic zircon may indeed combine effects of i) post-crystallization Pb loss from percolation of hydrothermal fluids (even using chemical abrasion), with ii) age dispersion from prolonged residence of earlier crystallized zircon in the magmatic system. As a result, U-Pb dates of individual zircons are both apparently younger and older than the depositional age

  4. Automatic identification of otologic drilling faults: a preliminary report.

    Science.gov (United States)

    Shen, Peng; Feng, Guodong; Cao, Tianyang; Gao, Zhiqiang; Li, Xisheng

    2009-09-01

    A preliminary study was carried out to identify parameters to characterize drilling faults when using an otologic drill under various operating conditions. An otologic drill was modified by the addition of four sensors. Under consistent conditions, the drill was used to simulate three important types of drilling faults and the captured data were analysed to extract characteristic signals. A multisensor information fusion system was designed to fuse the signals and automatically identify the faults. When identifying drilling faults, there was a high degree of repeatability and regularity, with an average recognition rate of >70%. This study shows that the variables measured change in a fashion that allows the identification of particular drilling faults, and that it is feasible to use these data to provide rapid feedback for a control system. Further experiments are being undertaken to implement such a system.

  5. Preliminary characterization of human skin microbiome in healthy Egyptian individuals.

    Science.gov (United States)

    Ramadan, M; Solyman, S; Taha, M; Hanora, A

    2016-07-31

    Human skin is a large, complex ecosystem that harbors diverse microbial communities. The rapid advances in molecular techniques facilitate the exploration of skin associated bacterial populations. The objective of this study was to perform a preliminary characterization of skin associated bacterial populations in Egyptian individuals. Samples were collected from five healthy subjects from two skin sites; Antecubital Fossa (AF) and Popliteal Fossa (PF). Genomic DNA was extracted and used to amplify bacterial 16S rRNA genes which were sequenced on Illumina MiSeq platform. The two sites showed distinct diversity where PF was more diverse than AF. Taxonomic analysis of sequences revealed four main phyla Proteobacteria, Firmicutes, Actinobacteria and Deinococcus-Thermus, with Proteobacteria presenting the highest diversity. Klebsiella, Bacillus, Pseudomonas and Escherichia were the most predominant genera. Our data suggest that environmental factors can shape the composition of the skin microbiome in certain geographical regions. This study presents a new insight for subsequent analyses of human microbiome in Egypt.

  6. Preliminary acclimation strategies for successful startup in conventional biofilters.

    Science.gov (United States)

    Elías, Ana; Barona, Astrid; Gallastegi, Gorka; Rojo, Naiara; Gurtubay, Luis; Ibarra-Berastegi, Gabriel

    2010-08-01

    The question of how to obtain the best inocula for conventional biofilters arises when an acclimation/adaptation procedure is to be applied. Bearing in mind that no standardized procedure for acclimating inocula exists, certain preliminary strategies for obtaining an active inoculum from wastewater treatment sludge are proposed in this work. Toluene was the contaminant to be degraded. Concerning the prior separation of sludge phases, no obvious advantage was found in separating the supernatant phase of the sludge before acclimation. As far as a continuous or discontinuous acclimation mode is concerned, the latter is recommended for rapidly obtaining acclimated sludge samples by operating the system for no longer than 1 month. The continuous mode rendered similar degradation rates, although it required longer operating time. Nevertheless, the great advantage of the continuous system lay in the absence of daily maintenance and the ready availability of the activated sample.

  7. How Accurately Can Emergency Department Providers Estimate Patient Satisfaction?

    Directory of Open Access Journals (Sweden)

    Lalena M. Yarris

    2012-09-01

    Full Text Available Introduction: Patient satisfaction is an important measure of emergency department (ED quality of care. Little is known about providers’ ability to estimate patient satisfaction. We aimed to measure providers’ ability to assess patient satisfaction and hypothesized that providers could accurately estimate overall patient satisfaction.Methods: We surveyed ED patients regarding satisfaction with their care. Treating providers completed analogous surveys, estimating patients’ responses. Sexual assault victims and non-English-speaking or severely ill patients were excluded. Satisfaction responses were categorized as ‘‘satisfied’’ or ‘‘not satisfied.’’ Patient satisfaction scores were considered the ‘‘gold standard,’’ and providers’ perceptions of the patient satisfaction were considered tests. Measures of diagnosticaccuracy, such as positive predictive value (PPV and sensitivity, were used to assess how accurately the provider could estimate his or her patient’s satisfaction.Results: Here, 242/457 eligible patients (53% completed the survey; 227 providers (94% completed a corresponding survey. Subject-reported overall satisfaction was 96.6%, compared with a provider estimated rate of 94.4%. The sensitivity and PPV of the provider’s estimate of the patient’s satisfaction were 95.2 (95% confidence interval [CI] 91.4, 97.7 and 97.5 (95% CI 94.4, 99.2, respectively, for overall patient satisfaction. The PPV was similar for clarity of communication. The PPV was 78.9 for perceived length of ED stay (99% CI 70.8, 85.6 and 82.6 for quality of pain control (95% CI 68.6, 92.2. Accuracy of attending and resident estimates of patient satisfaction did not differ significantly. The agreement between patient-reported and provider-estimated patient satisfaction was not associated with age, gender, patient disposition, or ED divert status.Conclusion: Providers are able to assess overall patient satisfaction and clarity of

  8. Simple Mathematical Models Do Not Accurately Predict Early SIV Dynamics

    Directory of Open Access Journals (Sweden)

    Cecilia Noecker

    2015-03-01

    Full Text Available Upon infection of a new host, human immunodeficiency virus (HIV replicates in the mucosal tissues and is generally undetectable in circulation for 1–2 weeks post-infection. Several interventions against HIV including vaccines and antiretroviral prophylaxis target virus replication at this earliest stage of infection. Mathematical models have been used to understand how HIV spreads from mucosal tissues systemically and what impact vaccination and/or antiretroviral prophylaxis has on viral eradication. Because predictions of such models have been rarely compared to experimental data, it remains unclear which processes included in these models are critical for predicting early HIV dynamics. Here we modified the “standard” mathematical model of HIV infection to include two populations of infected cells: cells that are actively producing the virus and cells that are transitioning into virus production mode. We evaluated the effects of several poorly known parameters on infection outcomes in this model and compared model predictions to experimental data on infection of non-human primates with variable doses of simian immunodifficiency virus (SIV. First, we found that the mode of virus production by infected cells (budding vs. bursting has a minimal impact on the early virus dynamics for a wide range of model parameters, as long as the parameters are constrained to provide the observed rate of SIV load increase in the blood of infected animals. Interestingly and in contrast with previous results, we found that the bursting mode of virus production generally results in a higher probability of viral extinction than the budding mode of virus production. Second, this mathematical model was not able to accurately describe the change in experimentally determined probability of host infection with increasing viral doses. Third and finally, the model was also unable to accurately explain the decline in the time to virus detection with increasing viral

  9. [Application of rapid PCR to authenticate medicinal snakes].

    Science.gov (United States)

    Chen, Kang; Jiang, Chao; Yuan, Yuan; Huang, Lu-Qi; Li, Man

    2014-10-01

    To obtained an accurate, rapid and efficient method for authenticate medicinal snakes listed in Chinese Pharmacopoeia (Zaocysd humnades, Bungarus multicinctus, Agkistrodon acutus), a rapid PCR method for authenticate snakes and its adulterants was established based on the classic molecular authentication methods. DNA was extracted by alkaline lysis and the specific primers were amplified by two-steps PCR amplification method. The denatured and annealing temperature and cycle numbers were optimized. When 100 x SYBR Green I was added in the PCR product, strong green fluorescence was visualized under 365 nm UV whereas adulterants without. The whole process can complete in 30-45 minutes. The established method provides the technical support for authentication of the snakes on field.

  10. Accurate mass measurements of very short-lived nuclei

    CERN Document Server

    Herfurth, F; Ames, F; Audi, G; Beck, D; Blaum, K; Bollen, G; Engels, O; Kluge, H J; Lunney, M D; Moores, R B; Oinonen, M; Sauvan, E; Bolle, C A; Scheidenberger, C; Schwarz, S; Sikler, G; Weber, C

    2002-01-01

    Mass measurements of /sup 34/Ar, /sup 73-78/Kr, and /sup 74,76/Rb were performed with the Penning-trap mass spectrometer ISOLTRAP. Very accurate Q/sub EC/-values are needed for the investigations of the F /sub t/-value of 0/sup +/ to 0/sup +/ nuclear beta -decays used to test the standard model predictions for weak interactions. The necessary accuracy on the Q/sub EC/-value requires the mass of mother and daughter nuclei to be measured with delta m/m

  11. Accurate p-values for adaptive designs with binary endpoints.

    Science.gov (United States)

    Heritier, Stephane; Lloyd, Chris J; Lô, Serigne N

    2017-07-30

    Adaptive designs encompass all trials allowing various types of design modifications over the course of the trial. A key requirement for confirmatory adaptive designs to be accepted by regulators is the strong control of the family-wise error rate. This can be achieved by combining the p-values for each arm and stage to account for adaptations (including but not limited to treatment selection), sample size adaptation and multiple stages. While the theory for this is novel and well-established, in practice, these methods can perform poorly, especially for unbalanced designs and for small to moderate sample sizes. The problem is that standard stagewise tests have inflated type I error rate, especially but not only when the baseline success rate is close to the boundary and this is carried over to the adaptive tests, seriously inflating the family-wise error rate. We propose to fix this problem by feeding the adaptive test with second-order accurate p-values, in particular bootstrap p-values. Secondly, an adjusted version of the Simes procedure for testing intersection hypotheses that reduces the built-in conservatism is suggested. Numerical work and simulations show that unlike their standard counterparts the new approach preserves the overall error rate, at or below the nominal level across the board, irrespective of the baseline rate, stagewise sample sizes or allocation ratio. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  12. A New Path Generation Algorithm Based on Accurate NURBS Curves

    Directory of Open Access Journals (Sweden)

    Sawssen Jalel

    2016-04-01

    Full Text Available The process of finding an optimum, smooth and feasible global path for mobile robot navigation usually involves determining the shortest polyline path, which will be subsequently smoothed to satisfy the requirements. Within this context, this paper deals with a novel roadmap algorithm for generating an optimal path in terms of Non-Uniform Rational B-Splines (NURBS curves. The generated path is well constrained within the curvature limit by exploiting the influence of the weight parameter of NURBS and/or the control points' locations. The novelty of this paper lies in the fact that NURBS curves are not used only as a means of smoothing, but they are also involved in meeting the system's constraints via a suitable parameterization of the weights and locations of control points. The accurate parameterization of weights allows for a greater benefit to be derived from the influence and geometrical effect of this factor, which has not been well investigated in previous works. The effectiveness of the proposed algorithm is demonstrated through extensive MATLAB computer simulations.

  13. Accurate measurement method for tube's endpoints based on machine vision

    Science.gov (United States)

    Liu, Shaoli; Jin, Peng; Liu, Jianhua; Wang, Xiao; Sun, Peng

    2017-01-01

    Tubes are used widely in aerospace vehicles, and their accurate assembly can directly affect the assembling reliability and the quality of products. It is important to measure the processed tube's endpoints and then fix any geometric errors correspondingly. However, the traditional tube inspection method is time-consuming and complex operations. Therefore, a new measurement method for a tube's endpoints based on machine vision is proposed. First, reflected light on tube's surface can be removed by using photometric linearization. Then, based on the optimization model for the tube's endpoint measurements and the principle of stereo matching, the global coordinates and the relative distance of the tube's endpoint are obtained. To confirm the feasibility, 11 tubes are processed to remove the reflected light and then the endpoint's positions of tubes are measured. The experiment results show that the measurement repeatability accuracy is 0.167 mm, and the absolute accuracy is 0.328 mm. The measurement takes less than 1 min. The proposed method based on machine vision can measure the tube's endpoints without any surface treatment or any tools and can realize on line measurement.

  14. Accurate ab initio vibrational energies of methyl chloride

    Energy Technology Data Exchange (ETDEWEB)

    Owens, Alec, E-mail: owens@mpi-muelheim.mpg.de [Max-Planck-Institut für Kohlenforschung, Kaiser-Wilhelm-Platz 1, 45470 Mülheim an der Ruhr (Germany); Department of Physics and Astronomy, University College London, Gower Street, WC1E 6BT London (United Kingdom); Yurchenko, Sergei N.; Yachmenev, Andrey; Tennyson, Jonathan [Department of Physics and Astronomy, University College London, Gower Street, WC1E 6BT London (United Kingdom); Thiel, Walter [Max-Planck-Institut für Kohlenforschung, Kaiser-Wilhelm-Platz 1, 45470 Mülheim an der Ruhr (Germany)

    2015-06-28

    Two new nine-dimensional potential energy surfaces (PESs) have been generated using high-level ab initio theory for the two main isotopologues of methyl chloride, CH{sub 3}{sup 35}Cl and CH{sub 3}{sup 37}Cl. The respective PESs, CBS-35{sup  HL}, and CBS-37{sup  HL}, are based on explicitly correlated coupled cluster calculations with extrapolation to the complete basis set (CBS) limit, and incorporate a range of higher-level (HL) additive energy corrections to account for core-valence electron correlation, higher-order coupled cluster terms, scalar relativistic effects, and diagonal Born-Oppenheimer corrections. Variational calculations of the vibrational energy levels were performed using the computer program TROVE, whose functionality has been extended to handle molecules of the form XY {sub 3}Z. Fully converged energies were obtained by means of a complete vibrational basis set extrapolation. The CBS-35{sup  HL} and CBS-37{sup  HL} PESs reproduce the fundamental term values with root-mean-square errors of 0.75 and 1.00 cm{sup −1}, respectively. An analysis of the combined effect of the HL corrections and CBS extrapolation on the vibrational wavenumbers indicates that both are needed to compute accurate theoretical results for methyl chloride. We believe that it would be extremely challenging to go beyond the accuracy currently achieved for CH{sub 3}Cl without empirical refinement of the respective PESs.

  15. An Accurate Model of Mercury's Spin-Orbit Motion

    Science.gov (United States)

    Rambaux, Nicolas; Bois, Eric

    2005-01-01

    Our work deals with the physical and dynamical causes that induce librations around an equilibrium state defined by the 3:2 spin-orbit resonance of Mercury. In order to integrate the spin-orbit motion of Mercury we have used our gravitational model of the solar System including the Moon's spin-orbit motion. This model called SONYR (acronym of Spin-Orbit N-bodY Relativistic) was previously built by Bois Journet and Vokrouhlicky in accordance with the requirements of the Lunar Laser Ranging observational accuracy. Using the model we have identified and evaluated the main perturbations acting on the spin-orbit motion of Mercury such as the planetary interactions and the dynamical figure of the planet. Moreover the complete rotation of Mercury exhibits two proper frequencies namely 15.825 and 1089 years and one secular variation of 271043 years. Besides we have computed in the Hermean librations the impact of the variation of the greatest principal moment of inertia C/MR2 on the obliquity and on the libration in longitude (1.4 and 0.4 milliarseconds respectively for an increase of 1% on the C/MR2 value). We think that these accurate relations are also significant and useful in the context of the two upcoming missions BepiColombo and MESSENGER.

  16. A new generalized correlation for accurate vapor pressure

    Directory of Open Access Journals (Sweden)

    Luis Fernando Cardona Palacio

    2016-08-01

    Full Text Available In this work, a new generalized correlation for pure substances is proposed for the estimation of vapor pressure, applicable in wide temperature range. Was used equilibrium liquid-vapor data with 28 refrigerants and minimizing the sum of the squares of the relative deviation in liquid-vapour pressure were determined the parameters and constants characteristics of the new equation and generalized for any pure substance using the acentric factor. Vapor pressure predictions were made for 45 pure substances who they didn´t not participate in the minimization, generated percent relative average deviation of 1.6073%. The results were compared with others equations for calculating the vapor pressure and  the  comparison  indicates  that  the  proposed  method provide  more  accurate  results  than  other  methods  used  in  this  work. Finally, the calculations of enthalpies of vaporization were done with deviations of 0.880% and the Waring criterion was applied to check the constants presed in this paper

  17. Accurate stereochemistry for two related 22,26-epiminocholestene derivatives

    Energy Technology Data Exchange (ETDEWEB)

    Vega-Baez, José Luis; Sandoval-Ramírez, Jesús; Meza-Reyes, Socorro; Montiel-Smith, Sara; Gómez-Calvario, Victor [Facultad de Ciencias Químicas, Benemérita Universidad Autónoma de Puebla, Ciudad Universitaria, San Manuel, 72000 Puebla, Pue. (Mexico); Bernès, Sylvain, E-mail: sylvain-bernes@hotmail.com [DEP Facultad de Ciencias Químicas, UANL, Guerrero y Progreso S/N, Col. Treviño, 64570 Monterrey, NL (Mexico); Facultad de Ciencias Químicas, Benemérita Universidad Autónoma de Puebla, Ciudad Universitaria, San Manuel, 72000 Puebla, Pue. (Mexico)

    2008-04-01

    Regioselective opening of ring E of solasodine under various conditions afforded (25R)-22,26-epimino@@cholesta-5,22(N)-di@@ene-3β,16β-diyl diacetate (previously known as 3,16-diacetyl pseudosolasodine B), C{sub 31}H{sub 47}NO{sub 4}, or (22S,25R)-16β-hydr@@oxy-22,26-epimino@@cholesta-5-en-3β-yl acetate (a derivative of the naturally occurring alkaloid oblonginine), C{sub 29}H{sub 47}NO{sub 3}. In both cases, the reactions are carried out with retention of chirality at the C16, C20 and C25 stereogenic centers, which are found to be S, S and R, respectively. Although pseudosolasodine was synthesized 50 years ago, these accurate assignments clarify some controversial points about the actual stereochemistry for these alkaloids. This is of particular importance in the case of oblonginine, since this compound is currently under consideration for the treatment of aphasia arising from apoplexy; the present study defines a diastereoisomerically pure compound for pharmacological studies.

  18. PSnAP: Accurate Synthetic Address Streams through Memory Profiles

    Science.gov (United States)

    Olschanowsky, Catherine Mills; Tikir, Mustafa M.; Carrington, Laura; Snavely, Allan

    Memory address traces are an important information source; they drive memory simulations for performance modeling, systems design and application tuning. For long running applications, the direct use of an address trace is complicated by its size. Previous attempts to reduce trace size incurred a substantial penalty with respect to trace accuracy. We propose a novel method of memory profiling that enables the generation of highly accurate synthetic traces with space requirements typically under 1% of the original traces. We demonstrate the synthetic trace accuracy in terms of cache hit rates, spatial-temporal locality scores and locality surfaces. Simulated cache hit rates from synthetic traces are within 3.5% of observed and on average are within 1.0% for L1 cache. Our profiles are on average 60 times smaller than compressed traces. The combination of small profile sizes and high similarity to original traces makes our technique uniquely applicable to performance modeling and trace driven simulation of large-scale parallel scientific applications.

  19. AUTOMATED, HIGHLY ACCURATE VERIFICATION OF RELAP5-3D

    Energy Technology Data Exchange (ETDEWEB)

    George L Mesina; David Aumiller; Francis Buschman

    2014-07-01

    Computer programs that analyze light water reactor safety solve complex systems of governing, closure and special process equations to model the underlying physics. In addition, these programs incorporate many other features and are quite large. RELAP5-3D[1] has over 300,000 lines of coding for physics, input, output, data management, user-interaction, and post-processing. For software quality assurance, the code must be verified and validated before being released to users. Verification ensures that a program is built right by checking that it meets its design specifications. Recently, there has been an increased importance on the development of automated verification processes that compare coding against its documented algorithms and equations and compares its calculations against analytical solutions and the method of manufactured solutions[2]. For the first time, the ability exists to ensure that the data transfer operations associated with timestep advancement/repeating and writing/reading a solution to a file have no unintended consequences. To ensure that the code performs as intended over its extensive list of applications, an automated and highly accurate verification method has been modified and applied to RELAP5-3D. Furthermore, mathematical analysis of the adequacy of the checks used in the comparisons is provided.

  20. An Accurate Projector Calibration Method Based on Polynomial Distortion Representation

    Directory of Open Access Journals (Sweden)

    Miao Liu

    2015-10-01

    Full Text Available In structure light measurement systems or 3D printing systems, the errors caused by optical distortion of a digital projector always affect the precision performance and cannot be ignored. Existing methods to calibrate the projection distortion rely on calibration plate and photogrammetry, so the calibration performance is largely affected by the quality of the plate and the imaging system. This paper proposes a new projector calibration approach that makes use of photodiodes to directly detect the light emitted from a digital projector. By analyzing the output sequence of the photoelectric module, the pixel coordinates can be accurately obtained by the curve fitting method. A polynomial distortion representation is employed to reduce the residuals of the traditional distortion representation model. Experimental results and performance evaluation show that the proposed calibration method is able to avoid most of the disadvantages in traditional methods and achieves a higher accuracy. This proposed method is also practically applicable to evaluate the geometric optical performance of other optical projection system.