WorldWideScience

Sample records for range measured neg

  1. Predictive validity of measures of comorbidity in older community dwellers: the Insufficienza Cardiaca negli Anziani Residenti a Dicomano Study.

    Science.gov (United States)

    Di Bari, Mauro; Virgillo, Adriana; Matteuzzi, Daniela; Inzitari, Marco; Mazzaglia, Giampiero; Pozzi, Claudia; Geppetti, Pierangelo; Masotti, Giulio; Marchionni, Niccolò; Pini, Riccardo

    2006-02-01

    To compare the ability of five measures of comorbidity to predict mortality and incident disability in basic activities of daily living (BADLs) in unselected older persons. An assessment of the data obtained from the Insufficienza Cardiaca negli Anziani Residenti a Dicomano (ICARe Dicomano) Study, a longitudinal epidemiological survey on heart failure in older people. Dicomano, a small, rural town near Florence, Italy. The entire population aged 65 and older living in Dicomano, Italy, was enrolled in the ICARe Dicomano Study. At baseline (1995), comorbidity was quantified in 688 participants, based on clinical diagnoses, using disease count (DC), Charlson Comorbidity Index (CCI), Index of Co-Existent Diseases (ICED), and Geriatric Index of Comorbidity (GIC), or on drug use, using Chronic Disease Score (CDS). Incident ADL disability was assessed in 1999 and vital status in 2004. Mortality increased with the severity of comorbidity, with hazard ratios around 2 when comparing the highest and the lowest quartiles of DC, CCI, and ICED in Cox regressions adjusted for age, sex, and physical and cognitive performance. Prediction of mortality with GIC and CDS was only borderline significant. All measures predicted incident ADL disability; the strongest risk gradient (hazard ratio = 8.2 between the highest and lowest quartiles) was observed with ICED. Physical and, to a minor extent, cognitive performance added significantly to predicting mortality and incident BADL disability. All the measures of comorbidity predicted death and BADL disability in older community dwellers. DC, CCI, and ICED performed better than GIC and CDS. Physical performance measures are strong, independent contributors to the prediction of these outcomes.

  2. Outgassing measurement of an LHC collimator and estimation for the NEG performances

    CERN Document Server

    Kamiya, Junichiro; Jimenez, J M; Bregliozzi, G

    2011-01-01

    The outgassing rate of the collimators in the Large Hadron Collider (LHC) at CERN has an important role for the life-time of the Non-Evaporable Getter (NEC), and an accurate analysis allows the definition of future activities, like NEC vacuum activation. For these reasons, both, total outgassing rate and gas composition of a secondary collimator have been measured in the laboratory. The outgassing rate decreases by about two orders of magnitude by after bake-out and moreover, repeated bake-out further reduced the outgassing rate. The gas transmission through the NEC coated beam pipes and the resulting pressure distributions near the collimator were also measured in a dedicated setup. It is found that the main gas component after just 2 m of NEC coated beam pipe is CH(4) due to the extreme pumping speed of NEC for the other gases. Large amount of outgassing for H(2) and carbon related molecules are released when moving the collimator jaws. It is found that the NEC is very effective even in such case with large...

  3. Policy Issues in NEG Models: Established Results and Open Questions

    OpenAIRE

    Commendatore, Pasquale; Hammer, Christoph; Kubin, Ingrid; Petraglia, Carmelo

    2017-01-01

    This paper provides a non-technical overview of NEG models dealing with policy issues. Considered policy measures include alternative categories of public expenditure, international tax competition, unilateral actions of protection/liberalisation, and trade agreements. The implications of public intervention in two-region NEG models are discussed by unfolding the impact of policy measures on agglomeration/dispersion forces. Results are described in contrast with those obtained in standard non...

  4. Radar range measurements in the atmosphere.

    Energy Technology Data Exchange (ETDEWEB)

    Doerry, Armin Walter

    2013-02-01

    The earths atmosphere affects the velocity of propagation of microwave signals. This imparts a range error to radar range measurements that assume the typical simplistic model for propagation velocity. This range error is a function of atmospheric constituents, such as water vapor, as well as the geometry of the radar data collection, notably altitude and range. Models are presented for calculating atmospheric effects on radar range measurements, and compared against more elaborate atmospheric models.

  5. NEG-shift, Licensing, and Repair Strategies

    DEFF Research Database (Denmark)

    Christensen, Ken Ramshøj

    2008-01-01

    I entertain the idea that the cross-linguistic variation in the licensing of NEG-shift, the movement of negative objects to spec-NegP, can be accounted for by a few representational constraints that are not directly related to case licensing or feature checking, and which potentially conflict wit...

  6. Compact ranges in antenna and RCS measurements

    Science.gov (United States)

    Audone, B.

    1989-09-01

    With the increased complexity and extended frequency range of operation model measurements and far field test ranges are no longer suitable to satisfy the demand of accurate testing. Moreover plane wave test conditions are required for Radar Cross Section (RCS) measurements which represent a key point in stealth technology. Compact ranges represent the best test facilities available presently since they allow for indoor measurements under far field conditions in real time without any calculation effort. Several types of compact ranges are described and compared discussing their relevant advantages with regard to RCS and antenna measurements. In parallel to measuring systems sophisticated computer models were developed with such a high level of accuracy that it is questionable whether experiments give better results than theory. Tests performed on simple structures show the correlation between experimental results and theoretical ones derived on the basis of GTD computer codes.

  7. Development of low-cost, high-performance non-evaporable getter (NEG) pumps

    Energy Technology Data Exchange (ETDEWEB)

    Mase, Kazuhiko, E-mail: mase@post.kek.jp [Institute of Materials Structure Science, KEK, 1-1 Oho, Tsukuba 305-0801 (Japan); SOKENDAI (The Graduate University for Advanced Studies), 1-1 Oho, Tsukuba 305-0801 (Japan); Tanaka, Masato [Faculty of Engineering, Chiba University, 1-33 Yayoi-cho, Inage-ku 263-8522 (Japan); Ida, Naoya [Faculty of Science and Technology, Hirosaki University, 1 Bunkyocho, Hirosaki 036-8560 (Japan); Kodama, Hiraku [Faculty of Engineering, Yokohama National University, 79-5 Tokiwadai, Hodogaya-ku, Yokohama 240-8501 (Japan); Kikuchi, Takashi [Institute of Materials Structure Science, KEK, 1-1 Oho, Tsukuba 305-0801 (Japan)

    2016-07-27

    Low-cost, high-performance non-evaporable getter (NEG) pumps were constructed using commercial NEG pills comprising 70 wt% Zr, 24.6 wt% V, and 5.4 wt% Fe, a conflat flange with an outer diameter of 70, 152, or 203 mm (DN 40 CF, DN 100 CF, and DN 160 CF, respectively), and a tantalum heater. After activation at 400 °C for 30 min, the pumping speeds of a DN 40 CF NEG pump measured with the orifice method were 47–40, 8–6, 24–17, and 19–15 L/s for H{sub 2}, N{sub 2}, CO, and CO{sub 2} gasses, respectively. NEG pumps using DN 100 CF and DN 160 CF were also developed, and their pumping speeds are estimated. These NEG pumps are favorable alternatives to sputtering ion pumps in VSX beamlines because they do not produce hydrocarbons except during the activation period. The NEG pumps can also be used for accelerators, front ends, end stations, and differential pumping systems.

  8. NEG pumps can go to the extremes

    CERN Multimedia

    Manini, Paolo

    2004-01-01

    Non-evaporable getters are highly reactive materials, generally made of zirconium or titanium; NEG pumps are efficient and clean sinks for molecules and they regularly achieve pressures as low as 10¯11, or even 10¯13 mbar (½ page)

  9. Comparative study of four physical performance measures as predictors of death, incident disability, and falls in unselected older persons: the insufficienza Cardiaca negli Anziani Residenti a Dicomano Study.

    Science.gov (United States)

    Minneci, Cristina; Mello, Anna Maria; Mossello, Enrico; Baldasseroni, Samuele; Macchi, Loredana; Cipolletti, Stefano; Marchionni, Niccolò; Di Bari, Mauro

    2015-01-01

    To compare the ability of the Short Physical Performance Battery (SPPB), 4-m walk test (4mWT), 6-minute walk test (6MWT), and handgrip strength to predict mortality, incident disability, worsening mobility, and falls in older community dwellers. Cohort study. Population-based. Individuals aged 65 and older n = 561) without prevalent basic activity of daily living (ADL) disability participating. Separate logistic regression models were developed to predict incident ADL disability, worsening mobility, and falls in 3 years, and Cox regression models were used to assess 7-year risk of death as a function of the four tests, adjusting for covariates. Performance tests were reciprocally correlated at baseline. After 3 years, 33 (7.3%) of 453 participants reexamined were disabled in ADLs, 87 (20%) had worsening mobility, and 99 (22%) reported falls. Of the 561 baseline participants, 141 (25%) died over the 7 years. All measures predicted incident ADL disability, with adjusted odds ratios (ORs) per unit increase of 0.85 (95% confidence interval (CI) = 0.77-0.93) for handgrip strength, 0.08 (95% CI = 0.02-0.36) for 4mWT, 0.74 (95% CI = 0.61-0.89) for SPPB, and 0.993 (95% CI = 0.988-0.997) for 6MWT. Handgrip strength (OR = 0.88, 95% CI = 0.83-0.93), 4mWT (OR = 0.33, 95% CI = 0.11-0.94), and SPPB (OR = 0.81, 95%CI = 0.71-0.93) predicted worsening mobility. No measure predicted falls; only SPPB (hazard ratio (HR) = 0.92, 95% CI = 0.85-0.997) and 6MWT (HR = 0.997, 95% CI = 0.995-0.999) predicted death. Performance measures are independent predictors of relevant health outcomes, with the exception of falls. Because SPPB is easily applied and is the only measure predicting incident ADL disability, worsening mobility, and death, it is preferable to the other tests. © 2015, Copyright the Authors Journal compilation © 2015, The American Geriatrics Society.

  10. Ultrasonic range measurements on the human body

    NARCIS (Netherlands)

    Weenk, D.; van Beijnum, Bernhard J.F.; Droog, Adriaan; Hermens, Hermanus J.; Veltink, Petrus H.

    2013-01-01

    Ambulatory range estimation on the human body is important for the assessment of the performance of upper- and lower limb tasks outside a laboratory. In this paper an ultrasound sensor for estimating ranges on the human body is presented and validated during gait. The distance between the feet is

  11. Electron Stimulated Molecular Desorption of a NEG St 707 at Room Temperature

    CERN Document Server

    Le Pimpec, F; Laurent, Jean Michel

    2001-01-01

    Electron stimulated molecular desorption (ESD) from a NEG St 707 (SAES GettersTM) sample after conditioning and after saturation with isotopic carbon monoxide2,13C18O, has been studied on a laboratory setup. Measurements were performed using an electron beam of 300 eV kinetic energy, with an average electron intensity of 1.6 1015 electrons s-1. The electrons were impinging on the 15 cm2 target surface at perpendicular incidence. It is found that the desorption yields h (molecules/electron) of the characteristic gases in an UHV system (hydrogen, methane, water, carbon monoxide, carbon dioxide) for a fully activated NEG as well as for a NEG fully saturated with 13C18O are lower than for OFHC copper baked at 120oC. A small fraction only of the gas which is required to saturate the getter surface can be re-desorbed and thus appears to be accessible to ESD.

  12. POS-1 promotes endo-mesoderm development by inhibiting the cytoplasmic polyadenylation of neg-1 mRNA

    Science.gov (United States)

    Elewa, Ahmed; Shirayama, Masaki; Kaymak, Ebru; Harrison, Paul F.; Powell, David R.; Du, Zhuo; Chute, Christopher D.; Woolf, Hannah; Yi, Dongni; Ishidate, Takao; Srinivasan, Jagan; Bao, Zhirong; Beilharz, Traude H.; Ryder, Sean; Mello, Craig C.

    2015-01-01

    SUMMARY The regulation of mRNA translation is of fundamental importance in biological mechanisms ranging from embryonic axis specification to formation of long-term memory. POS-1 is one of several CCCH zinc-finger RNA-binding proteins that regulate cell-fate specification during C. elegans embryogenesis. Paradoxically, pos-1 mutants exhibit striking defects in endo-mesoderm development, but have wildtype distributions of SKN-1, a key determinant of endo-mesoderm fates. RNAi screens for pos-1 suppressors identified genes encoding the cytoplasmic poly(A)-polymerase homolog GLD-2, the Bicaudal-C homolog GLD-3, and the protein NEG-1. We show that NEG-1 localizes in anterior nuclei where it negatively regulates endo-mesoderm fates. In posterior cells, POS-1 binds the neg-1 3′UTR to oppose GLD-2 and GLD-3 activities that promote NEG-1 expression and cytoplasmic lengthening of the neg-1 mRNA poly(A) tail. Our findings uncover an intricate series of post-transcriptional regulatory interactions that together achieve precise spatial expression of endo-mesoderm fates in C. elegans embryos. PMID:26096734

  13. High speed high dynamic range high accuracy measurement system

    Science.gov (United States)

    Deibele, Craig E.; Curry, Douglas E.; Dickson, Richard W.; Xie, Zaipeng

    2016-11-29

    A measuring system includes an input that emulates a bandpass filter with no signal reflections. A directional coupler connected to the input passes the filtered input to electrically isolated measuring circuits. Each of the measuring circuits includes an amplifier that amplifies the signal through logarithmic functions. The output of the measuring system is an accurate high dynamic range measurement.

  14. Pile volume measurement by range imaging camera in indoor environment

    Directory of Open Access Journals (Sweden)

    C. Altuntas

    2014-06-01

    Full Text Available Range imaging (RIM camera is recent technology in 3D location measurement. The new study areas have been emerged in measurement and data processing together with RIM camera. It has low-cost and fast measurement technique compared to the current measurement techniques. However its measurement accuracy varies according to effects resulting from the device and the environment. The direct sunlight is affect measurement accuracy of the camera. Thus, RIM camera should be used for indoor measurement. In this study gravel pile volume was measured by SwissRanger SR4000 camera. The measured volume is acquired as different 8.13% from the known.

  15. Discrete filtering techniques applied to sequential GPS range measurements

    Science.gov (United States)

    Vangraas, Frank

    1987-01-01

    The basic navigation solution is described for position and velocity based on range and delta range (Doppler) measurements from NAVSTAR Global Positioning System satellites. The application of discrete filtering techniques is examined to reduce the white noise distortions on the sequential range measurements. A second order (position and velocity states) Kalman filter is implemented to obtain smoothed estimates of range by filtering the dynamics of the signal from each satellite separately. Test results using a simulated GPS receiver show a steady-state noise reduction, the input noise variance divided by the output noise variance, of a factor of four. Recommendations for further noise reduction based on higher order Kalman filters or additional delta range measurements are included.

  16. Comparison of methods of measuring active cervical range of motion.

    Science.gov (United States)

    Whitcroft, Katherine L; Massouh, Laura; Amirfeyz, Rouin; Bannister, Gordon

    2010-09-01

    Experimental study. Cervical range of motion (CROM) was measured using different clinical methods. To compare the reliability and accuracy of visual estimation, tape measurement, and the universal goniometer (UG) with that of the CROM goniometer in measuring active CROM in healthy volunteers. The secondary objective was to identify the single neck movement that best represents overall range of motion. Neck movement is affected by pathology in the spine and shoulder. A reliable and accurate measurement of neck movement is required to quantify injury, recovery, and disability. Various methods of measuring neck movement have been described of which radiography remains the accepted reference standard. However, radiography is impractical for routine clinical assessment. Visual estimation, tape measurement, and the UG are convenient alternatives. To date, the accuracy and reliability of these methods have not been compared in healthy subjects, and the single neck movement that best reflects overall range has not yet been identified. Active cervical flexion, extension, right and left lateral flexion and rotation were measured in 100 healthy volunteers. Visual estimation, tape measurement between fixed landmarks, and the UG aligned on fixed and anatomic landmarks were compared with the CROM goniometer, which was used as the reference standard. Compared with the CROM goniometer, the UG aligned on fixed landmarks was the most accurate method, followed by the UG on anatomic landmarks. The reliability of the UG was between substantial and perfect. Visual estimation was reproducible but measured range of movement inaccurately. Tape measurement was inaccurate. Extension best reflected overall range. The UG aligned on a fixed landmark is most reliable method of measuring neck movement clinically. Where range must be quickly assessed, extension should be measured.

  17. High Precision Ranging and Range-Rate Measurements over Free-Space-Laser Communication Link

    Science.gov (United States)

    Yang, Guangning; Lu, Wei; Krainak, Michael; Sun, Xiaoli

    2016-01-01

    We present a high-precision ranging and range-rate measurement system via an optical-ranging or combined ranging-communication link. A complete bench-top optical communication system was built. It included a ground terminal and a space terminal. Ranging and range rate tests were conducted in two configurations. In the communication configuration with 622 data rate, we achieved a two-way range-rate error of 2 microns/s, or a modified Allan deviation of 9 x 10 (exp -15) with 10 second averaging time. Ranging and range-rate as a function of Bit Error Rate of the communication link is reported. They are not sensitive to the link error rate. In the single-frequency amplitude modulation mode, we report a two-way range rate error of 0.8 microns/s, or a modified Allan deviation of 2.6 x 10 (exp -15) with 10 second averaging time. We identified the major noise sources in the current system as the transmitter modulation injected noise and receiver electronics generated noise. A new improved system will be constructed to further improve the system performance for both operating modes.

  18. A quantum inspired model of radar range and range-rate measurements with applications to weak value measurements

    Science.gov (United States)

    Escalante, George

    2017-05-01

    Weak Value Measurements (WVMs) with pre- and post-selected quantum mechanical ensembles were proposed by Aharonov, Albert, and Vaidman in 1988 and have found numerous applications in both theoretical and applied physics. In the field of precision metrology, WVM techniques have been demonstrated and proven valuable as a means to shift, amplify, and detect signals and to make precise measurements of small effects in both quantum and classical systems, including: particle spin, the Spin-Hall effect of light, optical beam deflections, frequency shifts, field gradients, and many others. In principal, WVM amplification techniques are also possible in radar and could be a valuable tool for precision measurements. However, relatively limited research has been done in this area. This article presents a quantum-inspired model of radar range and range-rate measurements of arbitrary strength, including standard and pre- and post-selected measurements. The model is used to extend WVM amplification theory to radar, with the receive filter performing the post-selection role. It is shown that the description of range and range-rate measurements based on the quantum-mechanical measurement model and formalism produces the same results as the conventional approach used in radar based on signal processing and filtering of the reflected signal at the radar receiver. Numerical simulation results using simple point scatterrer configurations are presented, applying the quantum-inspired model of radar range and range-rate measurements that occur in the weak measurement regime. Potential applications and benefits of the quantum inspired approach to radar measurements are presented, including improved range and Doppler measurement resolution.

  19. Smartphone photography utilized to measure wrist range of motion.

    Science.gov (United States)

    Wagner, Eric R; Conti Mica, Megan; Shin, Alexander Y

    2018-02-01

    The purpose was to determine if smartphone photography is a reliable tool in measuring wrist movement. Smartphones were used to take digital photos of both wrists in 32 normal participants (64 wrists) at extremes of wrist motion. The smartphone measurements were compared with clinical goniometry measurements. There was a very high correlation between the clinical goniometry and smartphone measurements, as the concordance coefficients were high for radial deviation, ulnar deviation, wrist extension and wrist flexion. The Pearson coefficients also demonstrated the high precision of the smartphone measurements. The Bland-Altman plots demonstrated 29-31 of 32 smartphone measurements were within the 95% confidence interval of the clinical measurements for all positions of the wrists. There was high reliability between the photography taken by the volunteer and researcher, as well as high inter-observer reliability. Smartphone digital photography is a reliable and accurate tool for measuring wrist range of motion. II.

  20. Modelos de Negócio na Era Digital

    OpenAIRE

    Siqueira, Luciene Diana; CRISPIM, Sérgio Feliciano

    2012-01-01

    O termo de modelo de negócio passou a ser utilizado proeminente no final dos anos 1990, coincidindo com o advento da Internet no mundo dos negócios e acentuando-se com o desenvolvimento do mercado de ações da NASDAQ para empresas de tecnologia. Usado não somente no âmbito de mercados digitais, e muitas vezes tomado como sinônimo de estratégia, a literatura ainda apresenta uma falta de consenso quanto sua definição conceitual. Com a nova economia, a evolução da Internet possibilita novos model...

  1. Small Device For Short-Range Antenna Measurements Using Optics

    DEFF Research Database (Denmark)

    Yanakiev, Boyan Radkov; Nielsen, Jesper Ødum; Christensen, Morten

    2011-01-01

    This paper gives a practical solution for implementing an antenna radiation pattern measurement device using optical fibers. It is suitable for anechoic chambers as well as short range channel sounding. The device is optimized for small size and provides a cheap and easy way to make optical antenna...

  2. Measuring the relativistic perigee advance with satellite laser ranging

    CERN Document Server

    Iorio, L; Pavlis, E C

    2002-01-01

    The pericentric advance of a test body by a central mass is one of the classical tests of general relativity. Today, this effect is measured with radar ranging by the perihelion shift of Mercury and other planets in the gravitational field of the Sun, with a relative accuracy of the order of 10 sup - sup 2 -10 sup - sup 3. In this paper, we explore the possibility of a measurement of the pericentric advance in the gravitational field of Earth by analysing the laser-ranged data of some orbiting, or proposed, laser-ranged geodetic satellites. Such a measurement of the perigee advance would place limits on hypothetical, very weak, Yukawa-type components of the gravitational interaction with a finite range of the order of 10 sup 4 km. Thus, we show that, at the present level of knowledge of the orbital perturbations, the relative accuracy, achievable with suitably combined orbital elements of LAGEOS and LAGEOS II, is of the order of 10 sup - sup 3. With the corresponding measured value of (2 + 2 gamma - beta)/3, ...

  3. Ion range measurements using fluorescent nuclear track detectors

    DEFF Research Database (Denmark)

    Klimpki, G.; Osinga, J.-M.; Herrmann, R.

    2013-01-01

    Fluorescent nuclear track detectors (FNTDs) show excellent detection properties for heavy charged particles and have, therefore, been investigated in this study in terms of their potential for in-vivo range measurements. We irradiated FNTDs with protons as well as with C, Mg, S, Fe and Xe ion beams...

  4. Absolute stress measurements at the rangely anticline, Northwestern Colorado

    Science.gov (United States)

    de la Cruz, R. V.; Raleigh, C.B.

    1972-01-01

    Five different methods of measuring absolute state of stress in rocks in situ were used at sites near Rangely, Colorado, and the results compared. For near-surface measurements, overcoring of the borehole-deformation gage is the most convenient and rapid means of obtaining reliable values for the magnitude and direction of the state of stress in rocks in situ. The magnitudes and directions of the principal stresses are compared to the geologic features of the different areas of measurement. The in situ stresses are consistent in orientation with the stress direction inferred from the earthquake focal-plane solutions and existing joint patterns but inconsistent with stress directions likely to have produced the Rangely anticline. ?? 1972.

  5. Reliability of three measures of ankle dorsiflexion range of motion.

    Science.gov (United States)

    Konor, Megan M; Morton, Sam; Eckerson, Joan M; Grindstaff, Terry L

    2012-06-01

    A variety of methods exist to measure ankle dorsiflexion range of motion (ROM). Few studies have examined the reliability of a novice rater. The purpose of this study was to determine the reliability of ankle ROM measurements using three different techniques in a novice rater. Twenty healthy subjects (mean±SD, age=24±3 years, height=173.2±8.1 cm, mass=72.6±15.2 kg) participated in this study. Ankle dorsiflexion ROM measures were obtained in a weight-bearing lunge position using a standard goniometer, digital inclinometer, and a tape measure using the distance-to-wall technique. All measures were obtained three times per side, with 10 minutes of rest between the first and second set of measures. Intrarater reliability was determined using an intraclass correlation coefficient (ICC(2,3)) and associated 95% confidence intervals (CI). Standard error of measurement (SEM) and the minimal detectable change (MDC) for each measurement technique were also calculated. The within-session intrarater reliability (ICC(2,3)) estimates for each measure are as follows: tape measure (right 0.98, left 0.99), digital inclinometer (right 0.96; left 0.97), and goniometer (right 0.85; left 0.96). The SEM for the tape measure method ranged from 0.4-0.6 cm and the MDC was between 1.1-1.5 cm. The SEM for the inclinometer was between 1.3-1.4° and the MDC was 3.7-3.8°. The SEM for the goniometer ranged from 1.8-2.8° with an MDC of 5.0-7.7°. The results indicate that reliable measures of weight-bearing ankle dorsiflexion ROM can be obtained from a novice rater. All three techniques had good reliability and low measurement error, with the distance-to-wall technique using a tape measure and inclinometer methods resulting in higher reliability coefficients (ICC(2,3)=0.96 to 0.99) and a lower SEM compared to the goniometer (ICC(2,3)=0.85 to 0.96). 2b.

  6. Performance characteristics of lumped nonevaporable getter (NEG) pump

    Energy Technology Data Exchange (ETDEWEB)

    In, Sang-Ryul; Yokouchi, Shigeru; Be, Suck-Hee (JAERI-RIKEN SPring-8 Project Team, Wako, Saitama (Japan)); Maruyama, Takashi

    1991-12-01

    A prototype of the lumped NEG pump (LNP) designed as a main pump of the crotches and absorbers of the SPring-8 storage ring was manufactured with 14 nonevaporable getter (NEG) modules and a cylindrical pump body made of aluminum alloy. Vacuum Performance and operating characteristics of the LNP have been tested. Initial pumping speeds of the LNP for H{sub 2}, CO, N{sub 2} and CO{sub 2} were typically 3 m{sup 3}/s, 1.7 m{sup 3}/s, 1 m{sup 3}/s and 1.3 m{sup 3}/s, respectively. The experimental results were compared with the pumping speeds calculated by the Monte Carlo method. Equilibrium characteristics of the LNP in the activation period were studies to obtain basic data for the design of the auxiliary pumping system, and to set a pertinent activation schedule for the LNP. Operating characteristics such as the power consumption of the NEG modules and the temperature rise of the adjacent chambers including the aluminum alloy pump body during the NEG activation were also investigated. (author).

  7. Entanglement-enhanced lidars for simultaneous range and velocity measurements

    Science.gov (United States)

    Zhuang, Quntao; Zhang, Zheshen; Shapiro, Jeffrey H.

    2017-10-01

    Lidar is a well-known optical technology for measuring a target's range and radial velocity. We describe two lidar systems that use entanglement between transmitted signals and retained idlers to obtain significant quantum enhancements in simultaneous measurements of these parameters. The first entanglement-enhanced lidar circumvents the Arthurs-Kelly uncertainty relation for simultaneous measurements of range and radial velocity from the detection of a single photon returned from the target. This performance presumes there is no extraneous (background) light, but is robust to the round-trip loss incurred by the signal photons. The second entanglement-enhanced lidar—which requires a lossless, noiseless environment—realizes Heisenberg-limited accuracies for both its range and radial-velocity measurements, i.e., their root-mean-square estimation errors are both proportional to 1 /M when M signal photons are transmitted. These two lidars derive their entanglement-based enhancements from the use of a unitary transformation that takes a signal-idler photon pair with frequencies ωS and ωI and converts it to a signal-idler photon pair whose frequencies are (ωS+ωI)/2 and (ωS-ωI)/2 . Insight into how this transformation provides its benefits is provided through an analogy to continuous-variable superdense coding.

  8. Range-limited centrality measures in complex networks

    Science.gov (United States)

    Ercsey-Ravasz, Mária; Lichtenwalter, Ryan N.; Chawla, Nitesh V.; Toroczkai, Zoltán

    2012-06-01

    Here we present a range-limited approach to centrality measures in both nonweighted and weighted directed complex networks. We introduce an efficient method that generates for every node and every edge its betweenness centrality based on shortest paths of lengths not longer than ℓ=1,...,L in the case of nonweighted networks, and for weighted networks the corresponding quantities based on minimum weight paths with path weights not larger than wℓ=ℓΔ, ℓ=1,2...,L=R/Δ. These measures provide a systematic description on the positioning importance of a node (edge) with respect to its network neighborhoods one step out, two steps out, etc., up to and including the whole network. They are more informative than traditional centrality measures, as network transport typically happens on all length scales, from transport to nearest neighbors to the farthest reaches of the network. We show that range-limited centralities obey universal scaling laws for large nonweighted networks. As the computation of traditional centrality measures is costly, this scaling behavior can be exploited to efficiently estimate centralities of nodes and edges for all ranges, including the traditional ones. The scaling behavior can also be exploited to show that the ranking top list of nodes (edges) based on their range-limited centralities quickly freezes as a function of the range, and hence the diameter-range top list can be efficiently predicted. We also show how to estimate the typical largest node-to-node distance for a network of N nodes, exploiting the afore-mentioned scaling behavior. These observations were made on model networks and on a large social network inferred from cell-phone trace logs (˜5.5×106 nodes and ˜2.7×107 edges). Finally, we apply these concepts to efficiently detect the vulnerability backbone of a network (defined as the smallest percolating cluster of the highest betweenness nodes and edges) and illustrate the importance of weight-based centrality measures in

  9. Mode-locked laser autocollimator with an expanded measurement range.

    Science.gov (United States)

    Chen, Yuan-Liu; Shimizu, Yuki; Kudo, Yukitoshi; Ito, So; Gao, Wei

    2016-07-11

    A mode-locked laser is employed as the light source of a laser autocollimator, instead of the conventionally employed single-wavelength laser, for an expanded range of tilt angle measurement. A group of the spatially separated diffracted beams from a diffraction grating are focused by a collimator objective to form an array of light spots on the focal plane of the collimator objective where a light position-sensing photodiode is located for detecting the linear displacement of the light spot array corresponding to the tilt angle of the reflector. A prototype mode-locked femtosecond laser autocollimator is designed and constructed for achieving a measurement range of 11000 arc-seconds.

  10. An Observability Metric for Underwater Vehicle Localization Using Range Measurements

    Science.gov (United States)

    Arrichiello, Filippo; Antonelli, Gianluca; Aguiar, Antonio Pedro; Pascoal, Antonio

    2013-01-01

    The paper addresses observability issues related to the general problem of single and multiple Autonomous Underwater Vehicle (AUV) localization using only range measurements. While an AUV is submerged, localization devices, such as Global Navigation Satellite Systems, are ineffective, due to the attenuation of electromagnetic waves. AUV localization based on dead reckoning techniques and the use of affordable motion sensor units is also not practical, due to divergence caused by sensor bias and drift. For these reasons, localization systems often build on trilateration algorithms that rely on the measurements of the ranges between an AUV and a set of fixed transponders using acoustic devices. Still, such solutions are often expensive, require cumbersome calibration procedures and only allow for AUV localization in an area that is defined by the geometrical arrangement of the transponders. A viable alternative for AUV localization that has recently come to the fore exploits the use of complementary information on the distance from the AUV to a single transponder, together with information provided by on-board resident motion sensors, such as, for example, depth, velocity and acceleration measurements. This concept can be extended to address the problem of relative localization between two AUVs equipped with acoustic sensors for inter-vehicle range measurements. Motivated by these developments, in this paper, we show that both the problems of absolute localization of a single vehicle and the relative localization of multiple vehicles can be treated using the same mathematical framework, and tailoring concepts of observability derived for nonlinear systems, we analyze how the performance in localization depends on the types of motion imparted to the AUVs. For this effect, we propose a well-defined observability metric and validate its usefulness, both in simulation and by carrying out experimental tests with a real marine vehicle during which the performance of an

  11. An Observability Metric for Underwater Vehicle Localization Using Range Measurements

    Directory of Open Access Journals (Sweden)

    Filippo Arrichiello

    2013-11-01

    Full Text Available The paper addresses observability issues related to the general problem of single and multiple Autonomous Underwater Vehicle (AUV localization using only range measurements. While an AUV is submerged, localization devices, such as Global Navigation Satellite Systems, are ineffective, due to the attenuation of electromagnetic waves. AUV localization based on dead reckoning techniques and the use of affordable motion sensor units is also not practical, due to divergence caused by sensor bias and drift. For these reasons, localization systems often build on trilateration algorithms that rely on the measurements of the ranges between an AUV and a set of fixed transponders using acoustic devices. Still, such solutions are often expensive, require cumbersome calibration procedures and only allow for AUV localization in an area that is defined by the geometrical arrangement of the transponders. A viable alternative for AUV localization that has recently come to the fore exploits the use of complementary information on the distance from the AUV to a single transponder, together with information provided by on-board resident motion sensors, such as, for example, depth, velocity and acceleration measurements. This concept can be extended to address the problem of relative localization between two AUVs equipped with acoustic sensors for inter-vehicle range measurements. Motivated by these developments, in this paper, we show that both the problems of absolute localization of a single vehicle and the relative localization of multiple vehicles can be treated using the same mathematical framework, and tailoring concepts of observability derived for nonlinear systems, we analyze how the performance in localization depends on the types of motion imparted to the AUVs. For this effect, we propose a well-defined observability metric and validate its usefulness, both in simulation and by carrying out experimental tests with a real marine vehicle during which the

  12. Optical measurements of long-range protein vibrations

    Science.gov (United States)

    Acbas, Gheorghe; Niessen, Katherine A.; Snell, Edward H.; Markelz, A. G.

    2014-01-01

    Protein biological function depends on structural flexibility and change. From cellular communication through membrane ion channels to oxygen uptake and delivery by haemoglobin, structural changes are critical. It has been suggested that vibrations that extend through the protein play a crucial role in controlling these structural changes. While nature may utilize such long-range vibrations for optimization of biological processes, bench-top characterization of these extended structural motions for engineered biochemistry has been elusive. Here we show the first optical observation of long-range protein vibrational modes. This is achieved by orientation-sensitive terahertz near-field microscopy measurements of chicken egg white lysozyme single crystals. Underdamped modes are found to exist for frequencies >10 cm-1. The existence of these persisting motions indicates that damping and intermode coupling are weaker than previously assumed. The methodology developed permits protein engineering based on dynamical network optimization.

  13. Measurement of individual loudness functions by trisection of loudness ranges.

    Science.gov (United States)

    Villchur, Edgar; Killion, Mead C

    2008-10-01

    Loudness-balance measurements with monaurally impaired subjects have shown that the shape of the loudness versus sound-pressure curve among hearing-impaired persons varies significantly. But the effectiveness of adjusting the compression characteristics of wide-dynamic-range compression hearing aids-the compression ratios, the variation of compression ratio with level, and the threshold of compression-to restore normal loudness growth for the individual patient has never been properly tested; individual loudness measurements have been too uncertain to permit meaningful individual adjustments. Recent investigators have reported standard deviations of such measurements in normal-hearing subjects of 6.4 dB and 7.8 dB. This investigation describes a method of measuring loudness function with a standard deviation in normal-hearing subjects of the order of 1 dB, both significantly lower than that of previous methods and sufficiently accurate for individual-subject adjustments. Each of nine normal-hearing subjects-seven of them inexperienced and one a 9-year-old was asked to make three successive loudness trisections within an amplitude range of 40 to 80 dB SPL, providing six points from which to plot a loudness-function curve between these limits. The individual and average curves were validated as accurate loudness functions by comparing them to the curve defined by the equation of loudness versus amplitude in current Standards. In a second validation experiment, the loudness functions of masked ears measured by trisection were compared to the loudness function of those ears measured by loudness balance between masked and unmasked ears. The difference between a loudness function based on the average of subject trisections and the loudness function defined by the ANSI Standard loudness equation was -1.92 dB at the lowest trisection level and +0.05 dB at the highest level. The standard deviations of subject responses were 1.63 dB for the lowest trisection level and 0.68 d

  14. Livros digitais e os modelos de negócios

    OpenAIRE

    Serra, Liliana Giusti; Silva, José Fernando Modesto da

    2015-01-01

    O estudo enfoca a questão do licenciamento de livros digitais pelas bibliotecas a partir da análise dos principais modelos de negócios existentes (Aquisição perpétua, Assinatura, DDA, STL e EBS), com o objetivo de analisar as alterações decorrentes para o desenvolvimento de coleções. A partir de revisão de literatura e dos relatos de experiências identificam-se particularidades e características dos modelos de negócios e suas implicações para a gestão dos acervos bibliográficos, apresentando ...

  15. Measuring Systems for Thermometer Calibration in Low-Temperature Range

    Science.gov (United States)

    Szmyrka-Grzebyk, A.; Lipiński, L.; Manuszkiewicz, H.; Kowal, A.; Grykałowska, A.; Jancewicz, D.

    2011-12-01

    The national temperature standard for the low-temperature range between 13.8033 K and 273.16 K has been established in Poland at the Institute of Low Temperature and Structure Research (INTiBS). The standard consists of sealed cells for realization of six fixed points of the International Temperature Scale of 1990 (ITS-90) in the low-temperature range, an adiabatic cryostat and Isotech water and mercury triple-point baths, capsule standard resistance thermometers (CSPRT), and AC and DC bridges with standard resistors for thermometers resistance measurements. INTiBS calibrates CSPRTs at the low-temperature fixed points with uncertainties less than 1 mK. In lower temperature range—between 2.5 K and about 25 K — rhodium-iron (RhFe) resistance thermometers are calibrated by comparison with a standard which participated in the EURAMET.T-K1.1 comparison. INTiBS offers a calibration service for industrial platinum resistance thermometers and for digital thermometers between 77 K and 273 K. These types of thermometers may be calibrated at INTiBS also in a higher temperature range up to 550°C. The Laboratory of Temperature Standard at INTiBS acquired an accreditation from the Polish Centre for Accreditation. A management system according to EN ISO/IEC 17025:2005 was established at the Laboratory and presented on EURAMET QSM Forum.

  16. Proton range verification in homogeneous materials through acoustic measurements

    Science.gov (United States)

    Nie, Wei; Jones, Kevin C.; Petro, Scott; Kassaee, Alireza; Sehgal, Chandra M.; Avery, Stephen

    2018-01-01

    Clinical proton beam quality assurance (QA) requires a simple and accurate method to measure the proton beam Bragg peak (BP) depth. Protoacoustics, the measurement of the pressure waves emitted by thermal expansion resulting from proton dose deposition, may be used to obtain the depth of the BP in a phantom by measuring the time-of-flight of the pressure wave. Rectangular and cylindrical phantoms of different materials (aluminum, lead, and polyethylene) were used for protoacoustic studies. Four different methods for analyzing the protoacoustic signals are compared. Data analysis shows that, for Methods 1 and 2, plastic phantoms have better accuracy than metallic ones because of the lower speed of sound. Method 3 does not require characterizing the speed of sound in the material, but it results in the largest error. Method 4 exhibits minimal error, less than 3 mm (with an uncertainty  ⩽1.5 mm) for all the materials and geometries. Psuedospectral wave-equation simulations (k-Wave MATLAB toolbox) are used to understand the origin of acoustic reflections within the phantom. The presented simulations and experiments show that protoacoustic measurements may provide a low cost and simple QA procedure for proton beam range verification as long as the proper phantoms and calculation methods are used.

  17. Broadband Measurement of Aerosol Extinction in the Visible Range

    Science.gov (United States)

    He, Quanfu; Bluvshtein, Nir; Segev, Lior; Flores, Michel; Rudich, Yinon; Washenfelder, Rebecca; Brown, Steven

    2017-04-01

    Atmospheric aerosols influence the Earth's radiative budget directly by scattering and absorbing incoming solar radiation. Aerosol direct forcing remains one of the largest uncertainties in quantifying the role that aerosols play in the Earth's radiative budget. The optical properties of aerosols vary as a function of wavelength, but few measurements reported the wavelength dependence of aerosol extinction cross section and complex refractive indices, particularly in the blue and visible spectral range. There is also currently a large gap in our knowledge of how the optical properties evolve as a function of atmospheric aging in the visible spectrum. In this study, we constructed a new and novel laboratory instrument to measure aerosol extinction as a function of wavelength, using cavity enhanced spectroscopy with a white light source. This broadband cavity enhanced spectroscopy (BBCES) covers the 395-700 nm spectral region using a broadband light source and a grating spectrometer with charge-coupled device detector (CCD). We evaluated this BBCES by measuring extinction cross section for aerosols that are pure scattering, slightly absorbing and strongly absorbing atomized from standard materials. We also retrieved the refractive indices from the measured extinction cross sections. Secondary organic aerosols from biogenic and anthropogenic precursors were "aged" to differential time scales (1 to 10 days) in an Oxidation Flow Reactor (OFR) under the combined influence of OH, O3 and UV light. The new BBCES was used to online measure the extinction cross sections of the SOA. This talk will provide a comprehensive understanding of aerosol optical properties alerting during aging process in the 395 - 700 nm spectrum.

  18. Picosecond X-ray streak camera dynamic range measurement

    Energy Technology Data Exchange (ETDEWEB)

    Zuber, C., E-mail: celine.zuber@cea.fr; Bazzoli, S.; Brunel, P.; Gontier, D.; Raimbourg, J.; Rubbelynck, C.; Trosseille, C. [CEA, DAM, DIF, F-91297 Arpajon (France); Fronty, J.-P.; Goulmy, C. [Photonis SAS, Avenue Roger Roncier, BP 520, 19106 Brive Cedex (France)

    2016-09-15

    Streak cameras are widely used to record the spatio-temporal evolution of laser-induced plasma. A prototype of picosecond X-ray streak camera has been developed and tested by Commissariat à l’Énergie Atomique et aux Énergies Alternatives to answer the Laser MegaJoule specific needs. The dynamic range of this instrument is measured with picosecond X-ray pulses generated by the interaction of a laser beam and a copper target. The required value of 100 is reached only in the configurations combining the slowest sweeping speed and optimization of the streak tube electron throughput by an appropriate choice of high voltages applied to its electrodes.

  19. Tunnel and Subsurface Void Detection and Range to Target Measurement

    Energy Technology Data Exchange (ETDEWEB)

    Phillip B. West

    2009-06-01

    Engineers and technicians at the Idaho National Laboratory invented, designed, built and tested a device capable of detecting and measuring the distance to, an underground void, or tunnel. Preliminary tests demonstrated positive detection of, and range to, a void thru as much as 30 meters of top-soil earth. Device uses acoustic driving point impedance principles pioneered by the Laboratory for well-bore physical properties logging. Data receipts recorded by the device indicates constructive-destructive interference patterns characteristic of acoustic wave reflection from a downward step-change in impedance mismatch. Prototype tests demonstrated that interference patterns in receipt waves could depict the patterns indicative of specific distances. A tool with this capability can quickly (in seconds) indicate the presence and depth/distance of a void or tunnel. Using such a device, border security and military personnel can identify threats of intrusion or weapons caches in most all soil conditions including moist and rocky.

  20. CENTIMETER COSMO-SKYMED RANGE MEASUREMENTS FOR MONITORING GROUND DISPLACEMENTS

    Directory of Open Access Journals (Sweden)

    F. Fratarcangeli

    2016-06-01

    Full Text Available The SAR (Synthetic Aperture Radar imagery are widely used in order to monitor displacements impacting the Earth surface and infrastructures. The main remote sensing technique to extract sub-centimeter information from SAR imagery is the Differential SAR Interferometry (DInSAR, based on the phase information only. However, it is well known that DInSAR technique may suffer for lack of coherence among the considered stack of images. New Earth observation SAR satellite sensors, as COSMO-SkyMed, TerraSAR-X, and the coming PAZ, can acquire imagery with high amplitude resolutions too, up to few decimeters. Thanks to this feature, and to the on board dual frequency GPS receivers, allowing orbits determination with an accuracy at few centimetres level, the it was proven by different groups that TerraSAR-X imagery offer the capability to achieve, in a global reference frame, 3D positioning accuracies in the decimeter range and even better just exploiting the slant-range measurements coming from the amplitude information, provided proper corrections of all the involved geophysical phenomena are carefully applied. The core of this work is to test this methodology on COSMO-SkyMed data acquired over the Corvara area (Bolzano – Northern Italy, where, currently, a landslide with relevant yearly displacements, up to decimeters, is monitored, using GPS survey and DInSAR technique. The leading idea is to measure the distance between the satellite and a well identifiable natural or artificial Persistent Scatterer (PS, taking in account the signal propagation delays through the troposphere and ionosphere and filtering out the known geophysical effects that induce periodic and secular ground displacements. The preliminary results here presented and discussed indicate that COSMO-SkyMed Himage imagery appear able to guarantee a displacements monitoring with an accuracy of few centimetres using only the amplitude data, provided few (at least one stable PS’s are

  1. NEG (non evaporable getter) pumps for organic compounds and water removal in EUVL tools

    Science.gov (United States)

    Conte, A.; Manini, P.; Raimondi, S.

    2008-03-01

    One of present EUVL challenges is to reduce as much as possible the organic compounds and water partial pressures during the lithographic process. These gases can in fact interact with sensitive surfaces and, in the presence of EUV radiation, decompose to generate carbon-based films and oxides, which are detrimental to the optics, reducing its performance, lifetime and significantly increasing the equipment total cost of ownership. With this respect, use of Non Evaporable Getter (NEG) pumps seems particularly attractive. Getter pumps are very clean, vibration-free, compact, able to deliver large pumping speed for all active gases, including water and hydrogen. In the present paper, we report for the first time the results of specific tests aimed at measuring the pumping speed for some selected organic compounds, namely toluene and decane (n-decane). The study shows that getter pumps can effectively sorb these large organic molecules with high speed and capacity. Speed and capacity increases when operating the getter cartridge at moderate temperature (e.g. 150-200°C), however remarkable sorption is achieved, even at room temperature, without any power applied. When coupled with turbo-molecular pumps NEG pumps have therefore the potential to improve the ultimate vacuum and mitigate the carbon/oxygen contamination in a UHV lithographic system.

  2. Fusing range measurements from ultrasonic beacons and a laser range finder for localization of a mobile robot.

    Science.gov (United States)

    Ko, Nak Yong; Kuc, Tae-Yong

    2015-05-11

    This paper proposes a method for mobile robot localization in a partially unknown indoor environment. The method fuses two types of range measurements: the range from the robot to the beacons measured by ultrasonic sensors and the range from the robot to the walls surrounding the robot measured by a laser range finder (LRF). For the fusion, the unscented Kalman filter (UKF) is utilized. Because finding the Jacobian matrix is not feasible for range measurement using an LRF, UKF has an advantage in this situation over the extended KF. The locations of the beacons and range data from the beacons are available, whereas the correspondence of the range data to the beacon is not given. Therefore, the proposed method also deals with the problem of data association to determine which beacon corresponds to the given range data. The proposed approach is evaluated using different sets of design parameter values and is compared with the method that uses only an LRF or ultrasonic beacons. Comparative analysis shows that even though ultrasonic beacons are sparsely populated, have a large error and have a slow update rate, they improve the localization performance when fused with the LRF measurement. In addition, proper adjustment of the UKF design parameters is crucial for full utilization of the UKF approach for sensor fusion. This study contributes to the derivation of a UKF-based design methodology to fuse two exteroceptive measurements that are complementary to each other in localization.

  3. Book review. Procedure cliniche e terapeutiche negli animali esotici. Marta Avanzi

    Directory of Open Access Journals (Sweden)

    Manuel Graziani

    2014-12-01

    Full Text Available Negli ultimi anni è in costante aumento il numero degli animali da compagnia, con la diretta conseguenza che negli ambulatori veterinari arrivano sempre più pet diversi dal cane e dal gatto. Per dare loro cure di qualità non è sufficiente conoscere soltanto la fisiologia e la patologia ma c'è bisogno di saper maneggiare correttamente questi animali non convenzionali, oltre che conoscere le procedure per arrivare a una diagnosi e quindi ad una terapia appropriata. Procedure cliniche e terapeutiche negli animali esotici di Marta Avanzi risponde al bisogno di conoscenza in un settore in cui la formazione accademica è ancora scarsa, a fronte di un aumento della richiesta di cure da parte dei proprietari. Come scrive l'autrice nella prefazione: "Non sempre il professionista ha la possibilità di seguire un periodo di tirocinio pratico presso colleghi più esperti e spesso è la mancanza di esperienza che scoraggia il neofita ad ampliare il range di specie a cui dedicarsi. Il libro nasce proprio dall'esigenza di colmare questa lacuna, rispondendo al bisogno crescente di formazione nel campo della cura e del trattamento degli animali esotici da compagnia". Il manuale della dott.ssa Avanzi illustra con chiarezza le procedure diagnostiche, anestesiologiche, terapeutiche indispensabili per la pratica clinica. Per questo è rivolto principalmente ai medici veterinari che si occupano degli animali esotici da compagnia quali furetti, conigli, roditori, uccelli e rettili, di cui vengono illustrate le tecniche fondamentali per maneggiarli e contenerli con competenza e sicurezza. Il volume, pubblicato nel grande formato 19,5x26,5 cm, contiene più di mille fotografie a colori, comprese quelle delle attrezzature specifiche per i vari casi. Un'iconografia ricchissima che ha la funzione di descrivere passo dopo passo le manovre e le procedure per trattare questi particolari pazienti. I capitoli sono 14 e descrivono circa 150 procedure, dalla dermatologia all

  4. Extending the range of turbidity measurement using polarimetry

    Energy Technology Data Exchange (ETDEWEB)

    Baba, Justin S.

    2017-11-21

    Turbidity measurements are obtained by directing a polarized optical beam to a scattering sample. Scattered portions of the beam are measured in orthogonal polarization states to determine a scattering minimum and a scattering maximum. These values are used to determine a degree of polarization of the scattered portions of the beam, and concentrations of scattering materials or turbidity can be estimated using the degree of polarization. Typically, linear polarizations are used, and scattering is measured along an axis that orthogonal to the direction of propagation of the polarized optical beam.

  5. Intensity autocorrelation measurements of frequency combs in the terahertz range

    Science.gov (United States)

    Benea-Chelmus, Ileana-Cristina; Rösch, Markus; Scalari, Giacomo; Beck, Mattias; Faist, Jérôme

    2017-09-01

    We report on direct measurements of the emission character of quantum cascade laser based frequency combs, using intensity autocorrelation. Our implementation is based on fast electro-optic sampling, with a detection spectral bandwidth matching the emission bandwidth of the comb laser, around 2.5 THz. We find the output of these frequency combs to be continuous even in the locked regime, but accompanied by a strong intensity modulation. Moreover, with our record temporal resolution of only few hundreds of femtoseconds, we can resolve correlated intensity modulation occurring on time scales as short as the gain recovery time, about 4 ps. By direct comparison with pulsed terahertz light originating from a photoconductive emitter, we demonstrate the peculiar emission pattern of these lasers. The measurement technique is self-referenced and ultrafast, and requires no reconstruction. It will be of significant importance in future measurements of ultrashort pulses from quantum cascade lasers.

  6. Silicon device performance measurements to support temperature range enhancement

    Science.gov (United States)

    Johnson, R. Wayne; Askew, Ray; Bromstead, James; Weir, Bennett

    1991-01-01

    The results of the NPN bipolar transistor (BJT) (2N6023) breakdown voltage measurements were analyzed. Switching measurements were made on the NPN BJT, the insulated gate bipolar transistor (IGBT) (TA9796) and the N-channel metal oxide semiconductor field effect transistor (MOSFET) (RFH75N05E). Efforts were also made to build a H-bridge inverter. Also discussed are the plans that have been made to do life testing on the devices, to build an inductive switching test circuit and to build a dc/dc switched mode converter.

  7. Offshore wind profiling using light detection and ranging measurements

    DEFF Research Database (Denmark)

    Pena Diaz, Alfredo; Hasager, Charlotte Bay; Gryning, Sven-Erik

    2009-01-01

    The advantages and limitations of the ZephlR (R), a continuous-wave, focused light detection and ranging (LiDAR) wind profiler, to observe offshore winds and turbulence characteristics were tested during a 6 month campaign at the tronsformer/platform of Hams Rev, the world's largest wind form......-derived friction velocities and roughness lengths were compared to Charnock's sea roughness model. These overage values were found to be close to the model, although the scatter of the individual estimations of sea roughness length was large. Copyright (C) 2008 John Wiley & Sons, Ltd....

  8. Measurements of Capture Efficiency of Range Hoods in Homes

    DEFF Research Database (Denmark)

    Simone, Angela; Sherman, Max H.; Walker, Iain S.

    2015-01-01

    mapped the pollution distribution in the room, and showed that the pollutants escape more at the sides of the cooktop. These preliminary results suggest that more measurements should be conducted investigating the capture efficiency at different pollutant source temperature, size and location...

  9. Nanoemulgel (NEG) of Ketoprofen with eugenol as oil phase for the treatment of ligature-induced experimental periodontitis in Wistar rats.

    Science.gov (United States)

    Srivastava, Manish; Neupane, Yub Raj; Kumar, Parveen; Kohli, Kanchan

    2016-09-01

    The aim of the novel study was to check the efficacy of a locally applied 2%w/w nanoemulgel (NEG) of Ketoprofen (KP) in preventing the periodontitis, and was also checked NEG without KP to ensure the effect of eugenol in NEG as an oil phase. For experimentally induced periodontitis, sterile silk ligatures (3/0) were placed around the crevices of the first left lower molar teeth of the male Wistar rats. During 8 weeks, all rats were fed with 10%w/v sucrose solution. The experimental assessment was carried out at 11 d after treatment of experimental periodontal disease (EPD) rats by various clinical parameters like gingival index (GI), tooth mobility (TM), alveolar bone loss (ABL), histological analysis, detection of TNF-α, and IL-1β in gingival tissue by ELISA and the roughness were measured by atomic force microscopy (AFM) in tapping modes. After treatment, comparison studies with EPD were performed. NEG loaded with KP prevents significantly (p eugenol as the oil phase, which have potential antibacterial, analgesic, and anesthetic properties to combat periodontal disease.

  10. Robust Long-Range Optical Tracking for Tunneling Measurement Tasks

    Science.gov (United States)

    Mossel, Annette; Gerstweiler, Georg; Vonach, Emanuel; Chmelina, Klaus; Kaufmann, Hannes

    2013-04-01

    Over the last years, automation for tunnel construction and mining activities increased rapidly. To allow for enhanced tunneling measurement, monitoring of workers and remote control of machines, systems are required that are capable of real-time positioning of several static as well as moving targets. Such a system must provide continuous and precise 3D position estimation in large volumes and must be capable to be installed and work correctly during on-going tunneling or mining tasks. Tracking systems are a fundamental component of a VR system to determine the 3D-position and orientation of a target in 3D space. Infrared optical tracking systems use infrared light to track several static or moving targets simultaneously with low latency in small tracking volumes. To benefit from the capabilities of infrared optical tracking, a system is proposed to track static as well as moving optical targets in large tracking volumes with a maximum depth extend of 70 meters. Our system needs a minimal hardware setup consisting out of two high quality machine vision cameras, which are mounted on both walls of the tunnel, and a standard (portable) workstation for data processing. Targets are equipped with infrared LEDs and can be either carried by workers or attached to a machine. The two cameras form a stereo rig and face into the measurement volume to allow for continuous tracking. Using image processing techniques, the LEDs of the target(s) are detected in both 2D camera images and are back-projected into 3D using projective reconstruction algorithms. Thereby, the 3D position estimate of the target is determined. Using image filtering techniques, fitting methods based on target's geometric constraints and prediction heuristics, the system allows for unique target identification during calibration and tracking even in environments with heavy interferences such as vibrations, tunnel illumination or machine lights. We extensively tested the system to (1) determine optimal

  11. Panorama dos modelos de negócios emerg entes da tv digital aberta

    OpenAIRE

    Felippe Souza de Lima; Danilo Leme Bressan; Francisco Rolfsen Belda; Gisleine Fátima Durigan; Matheus Monteiro de Lima

    2015-01-01

    O presente artigo tem como objetivo descrever modelos de negócios emergentes aplicados àTV digital aberta. A partir de uma pesquisa exploratória, o trabalho apresenta a atual realidadeda televisão aberta e seus modelos de negócios. Posteriormente, é feito um mapeamentopanorâmico buscando, assim, novas oportunidades de geração de receitas em negócio decomunicação audiovisual, considerando novos recursos tecnológicos que foramproporcionados pela digitalização da televisão aberta. Por fim, são a...

  12. Long-range measurement system using ultrasonic range sensor with high-power transmitter array in air.

    Science.gov (United States)

    Kumar, Sahdev; Furuhashi, Hideo

    2017-02-01

    A long-range measurement system comprising an ultrasonic range sensor with a high-power ultrasonic transmitter array in air was investigated. The system is simple in construction and can be used under adverse conditions such as fog, rain, darkness, and smoke. However, due to ultrasonic waves are well absorbed by air molecules, the measurable range is limited to a few meters. Therefore, we developed a high-power ultrasonic transmitter array consisting of 144 transmitting elements. All elements are arranged in the form of a 12×12 array pattern. The sound pressure level at 5m from the transmitter array was >30dB higher than that of a single element. A measuring range of over 25m was achieved using this transmitter array in conjunction with a receiver array having 32 receiving elements. The characteristics of the transmitter array and range sensor system are discussed by comparing simulation and experimental results. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Measured Response of Local, Mid-range and Far-range Discontinuities of Large Metal Groundplanes using Time Domain Techniques

    Directory of Open Access Journals (Sweden)

    T. Schrader

    2005-01-01

    Full Text Available This work describes a method to detect and to quantify any local or mid-range discontinuity on extended flat metal planes. Often these planes are used for antenna calibration (open area test site - OATS or the plane could be the ground of a semi-anechoic chamber used in Electromagnetic Compatibility (EMC testing. The measurement uncertainty of antenna calibration or EMC testing depends on the groundplane's quality, which can be accessed using this method. A vector network analyzer with time-domain option is used to determine the complex-valued input scattering parameter S11,F of an aperture antenna in a monostatic setup. S11,F contains the information desired about the discontinuities and is measured in the frequency domain with high dynamic range. But only after a linear filtering utilizing the Chirp-Z-Transform the obtained time-domain signal S11,T evidence of local and mid-range discontinuities.

  14. Panorama dos modelos de negócios emerg entes da tv digital aberta

    Directory of Open Access Journals (Sweden)

    Felippe Souza de Lima

    2015-12-01

    Full Text Available O presente artigo tem como objetivo descrever modelos de negócios emergentes aplicados àTV digital aberta. A partir de uma pesquisa exploratória, o trabalho apresenta a atual realidadeda televisão aberta e seus modelos de negócios. Posteriormente, é feito um mapeamentopanorâmico buscando, assim, novas oportunidades de geração de receitas em negócio decomunicação audiovisual, considerando novos recursos tecnológicos que foramproporcionados pela digitalização da televisão aberta. Por fim, são apresentados casos,demonstrando maneiras adotadas por emissoras televisivas para gerar conteúdo adicionalmultiplataforma e desdobramentos estratégicos desenvolvidos para captar receitas por meiodestes modelos de negócios emergentes.

  15. Range Measurements of keV Hydrogen Ions in Solid Oxygen and Carbon Monoxide

    DEFF Research Database (Denmark)

    Schou, Jørgen; Sørensen, H.; Andersen, H.H.

    1984-01-01

    Ranges of 1.3–3.5 keV/atom hydrogen and deuterium molecular ions have been measured by a thin-film reflection method. The technique, used here for range measurements in solid oxygen and carbon monoxide targets, is identical to the one used previously for range measurements in hydrogen and nitrogen....... The main aim was to look for phase-effects, i.e. gas-solid differences in the stopping processes. While measured ranges in solid oxygen were in agreement with known gas data, the ranges in solid carbon monoxide were up to 50% larger than those calculated from gas-stopping data. The latter result agrees...

  16. Communication system features dual mode range acquisition plus time delay measurement

    Science.gov (United States)

    Atwood, S. W.; Kline, A. W., Jr.; Welter, N. E.

    1968-01-01

    Communication system combines range acquisition system and time measurement system for tracking high velocity aircraft and spacecraft. The range acquisition system uses a pseudonoise code to determine range and the time measurement system reduces uncontrolled phase variations in the demodulated signal.

  17. Weightbearing and nonweightbearing ankle dorsiflexion range of motion: are we measuring the same thing?

    Science.gov (United States)

    Rabin, Alon; Kozol, Zvi

    2012-01-01

    Ankle dorsiflexion range of motion has been measured in weightbearing and nonweightbearing conditions. The different measurement conditions may contribute to inconsistent conclusions regarding the role of ankle dorsiflexion in several pathologic conditions. The purpose of this study was to examine the relationship between ankle dorsiflexion range of motion as measured in weightbearing and nonweightbearing conditions. We compared ankle dorsiflexion range of motion as measured in a weightbearing versus a nonweightbearing position in 43 healthy volunteers. Measurements were taken separately by two examiners. Weightbearing and nonweightbearing ankle dorsiflexion measurements produced significantly different results (P dorsiflexion measurements produce significantly different results and only a moderate correlation, suggesting that these two measurements should not be used interchangeably as measures of ankle dorsiflexion range of motion.

  18. Reliability of digital compass goniometer in knee joint range of motion measurement.

    Science.gov (United States)

    Yaikwawongs, Nammond; Limpaphayom, Noppachart; Wilairatana, Vajara

    2009-04-01

    To compare the reliability of range of motion measurement in the knee joint using a digital compass goniometer combined with inclinometer with standard range of motion measurement from roentgenographic picture. Range of flexion and extension of the knee joint in volunteer participants was measured by the newly developed digital compass goniometer combined with inclinometer (DCG). The results were compared with range of knee joint motion obtained from standard roentgenographic picture by intraclass correlation coefficient. Range of motion of knee joint measured by DCG correlated very well with the data obtained from standard knee roentgenographic picture. The intraclass correlation coefficient equals 0.973. The digital compass goniometer was a reliable tool to measure knee joint range of motion in flexion and extension plane.

  19. Program to perform research on use of lidar for range resolved turbulence measurements

    Science.gov (United States)

    Moskowitz, Warren P.; Garner, Richard C.

    1989-11-01

    The design of a lidar system capable of measuring remotely range resolved atmospheric turbulence is presented. The connection between the measured quantities and the accepted turbulence strength parameter (C sub n)-sq is developed theoretically. Simulations of an operating system were made, and the results provide a measure of system capability. A typical value for (C sub n)-sq of 10(exp -16) m to the -2/3 power at 3 km vertical range is measurable with a 200 m range resolution.

  20. Absorption and fluorescence characteristics of photo-activated adenylate cyclase nano-clusters from the amoeboflagellate Naegleria gruberi NEG-M strain

    Energy Technology Data Exchange (ETDEWEB)

    Penzkofer, A., E-mail: alfons.penzkofer@physik.uni-regensburg.de [Fakultaet fuer Physik, Universitaet Regensburg, Universitaetsstrasse 31, D-93053 Regensburg (Germany); Stierl, M.; Hegemann, P. [Institut fuer Biologie/Experimentelle Biophysik, Humboldt Universitaet zu Berlin, Invalidenstrasse 42, D-10115 Berlin (Germany); Kateriya, S. [Department of Biochemistry, University of Delhi South Campus, Benito Juarez Road, New Delhi 110021 (India)

    2012-01-02

    Graphical abstract: Protein color center emissions were observed in the wavelength range from 340 nm to 900 nm from nano-clusters of the photo-activated adenylate cyclase (nPAC) from the amoeboflagellate Naegleria gruberi. Highlights: Black-Right-Pointing-Pointer Adenylyl cyclase nPAC in aqueous pH 7.5 buffer dissolved only to nano-clusters. Black-Right-Pointing-Pointer Nano-cluster size was determined by light attenuation (scattering) measurements. Black-Right-Pointing-Pointer The size of the nano-clusters was growing by coalescing during observation period. Black-Right-Pointing-Pointer In nPAC nano-clusters color centers were present in emission range of 360-900 nm. Black-Right-Pointing-Pointer The nPAC color center emission is compared with fluorescent protein emission. - Abstract: The spectroscopic characteristics of BLUF (BLUF = sensor of blue light using flavin) domain containing soluble adenylate cyclase (nPAC = Naegleria photo-activated cyclase) samples from the amoeboflagellate Naegleria gruberi NEG-M strain is studied at room temperature. The absorption and fluorescence spectroscopic development in the dark was investigated over two weeks. Attenuation coefficient spectra, fluorescence quantum distributions, fluorescence quantum yields, and fluorescence excitation distributions were measured. Thawing of frozen nPAC samples gave solutions with varying protein nano-cluster size and varying flavin, tyrosine, tryptophan, and protein color-center emission. Protein color-center emission was observed in the wavelength range of 360-900 nm with narrow emission bands of small Stokes shift and broad emission bands of large Stokes shift. The emission spectra evolved in time with protein nano-cluster aging.

  1. Enhanced Strain Measurement Range of an FBG Sensor Embedded in Seven-Wire Steel Strands

    Directory of Open Access Journals (Sweden)

    Jae-Min Kim

    2017-07-01

    Full Text Available FBG sensors offer many advantages, such as a lack of sensitivity to electromagnetic waves, small size, high durability, and high sensitivity. However, their maximum strain measurement range is lower than the yield strain range (about 1.0% of steel strands when embedded in steel strands. This study proposes a new FBG sensing technique in which an FBG sensor is recoated with polyimide and protected by a polyimide tube in an effort to enhance the maximum strain measurement range of FBG sensors embedded in strands. The validation test results showed that the proposed FBG sensing technique has a maximum strain measurement range of 1.73% on average, which is 1.73 times higher than the yield strain of the strands. It was confirmed that recoating the FBG sensor with polyimide and protecting the FBG sensor using a polyimide tube could effectively enhance the maximum strain measurement range of FBG sensors embedded in strands.

  2. Correction of motion measurement errors beyond the range resolution of a synthetic aperture radar

    Science.gov (United States)

    Doerry, Armin W [Albuquerque, NM; Heard, Freddie E [Albuquerque, NM; Cordaro, J Thomas [Albuquerque, NM

    2008-06-24

    Motion measurement errors that extend beyond the range resolution of a synthetic aperture radar (SAR) can be corrected by effectively decreasing the range resolution of the SAR in order to permit measurement of the error. Range profiles can be compared across the slow-time dimension of the input data in order to estimate the error. Once the error has been determined, appropriate frequency and phase correction can be applied to the uncompressed input data, after which range and azimuth compression can be performed to produce a desired SAR image.

  3. Coherent change detection and interferometric ISAR measurements in the folded compact range

    Energy Technology Data Exchange (ETDEWEB)

    Sorensen, K.W.

    1996-08-01

    A folded compact range configuration has been developed ant the Sandia National Laboratories` compact range antenna and radar-cross- section measurement facility as a means of performing indoor, environmentally-controlled, far-field simulations of synthetic aperture radar (SAR) measurements of distributed target samples (i.e. gravel, sand, etc.). The folded compact range configuration has previously been used to perform coherent-change-detection (CCD) measurements, which allow disturbances to distributed targets on the order of fractions of a wavelength to be detected. This report describes follow-on CCD measurements of other distributed target samples, and also investigates the sensitivity of the CCD measurement process to changes in the relative spatial location of the SAR sensor between observations of the target. Additionally, this report describes the theoretical and practical aspects of performing interferometric inverse-synthetic-aperture-radar (IFISAR) measurements in the folded compact range environment. IFISAR measurements provide resolution of the relative heights of targets with accuracies on the order of a wavelength. Several examples are given of digital height maps that have been generated from measurements performed at the folded compact range facility.

  4. Multipath error in range rate measurement by PLL-transponder/GRARR/TDRS

    Science.gov (United States)

    Sohn, S. J.

    1970-01-01

    Range rate errors due to specular and diffuse multipath are calculated for a tracking and data relay satellite (TDRS) using an S band Goddard range and range rate (GRARR) system modified with a phase-locked loop transponder. Carrier signal processing in the coherent turn-around transponder and the GRARR reciever is taken into account. The root-mean-square (rms) range rate error was computed for the GRARR Doppler extractor and N-cycle count range rate measurement. Curves of worst-case range rate error are presented as a function of grazing angle at the reflection point. At very low grazing angles specular scattering predominates over diffuse scattering as expected, whereas for grazing angles greater than approximately 15 deg, the diffuse multipath predominates. The range rate errors at different low orbit altutudes peaked between 5 and 10 deg grazing angles.

  5. Optimal frequency range for medical radar measurements of human heartbeats using body-contact radar.

    Science.gov (United States)

    Brovoll, Sverre; Aardal, Øyvind; Paichard, Yoann; Berger, Tor; Lande, Tor Sverre; Hamran, Svein-Erik

    2013-01-01

    In this paper the optimal frequency range for heartbeat measurements using body-contact radar is experimentally evaluated. A Body-contact radar senses electromagnetic waves that have penetrated the human body, but the range of frequencies that can be used are limited by the electric properties of the human tissue. The optimal frequency range is an important property needed for the design of body-contact radar systems for heartbeat measurements. In this study heartbeats are measured using three different antennas at discrete frequencies from 0.1 - 10 GHz, and the strength of the received heartbeat signal is calculated. To characterize the antennas, when in contact with the body, two port S-parameters(†) are measured for the antennas using a pork rib as a phantom for the human body. The results shows that frequencies up to 2.5 GHz can be used for heartbeat measurements with body-contact radar.

  6. Employee Identification with Corporate Values within the Danish Windmill Company NEG Micon

    DEFF Research Database (Denmark)

    Andersen, Mona Agerholm

    2008-01-01

    This paper presents the findings of a holistic study of the communication processes during a corporate value implementation within the Danish windmill company NEG Micon. This implies firstly a study of the different processes of management's formulation, construction and communication of the value...

  7. DEEPEN: A negation detection system for clinical text incorporating dependency relation into NegEx.

    Science.gov (United States)

    Mehrabi, Saeed; Krishnan, Anand; Sohn, Sunghwan; Roch, Alexandra M; Schmidt, Heidi; Kesterson, Joe; Beesley, Chris; Dexter, Paul; Max Schmidt, C; Liu, Hongfang; Palakal, Mathew

    2015-04-01

    In Electronic Health Records (EHRs), much of valuable information regarding patients' conditions is embedded in free text format. Natural language processing (NLP) techniques have been developed to extract clinical information from free text. One challenge faced in clinical NLP is that the meaning of clinical entities is heavily affected by modifiers such as negation. A negation detection algorithm, NegEx, applies a simplistic approach that has been shown to be powerful in clinical NLP. However, due to the failure to consider the contextual relationship between words within a sentence, NegEx fails to correctly capture the negation status of concepts in complex sentences. Incorrect negation assignment could cause inaccurate diagnosis of patients' condition or contaminated study cohorts. We developed a negation algorithm called DEEPEN to decrease NegEx's false positives by taking into account the dependency relationship between negation words and concepts within a sentence using Stanford dependency parser. The system was developed and tested using EHR data from Indiana University (IU) and it was further evaluated on Mayo Clinic dataset to assess its generalizability. The evaluation results demonstrate DEEPEN, which incorporates dependency parsing into NegEx, can reduce the number of incorrect negation assignment for patients with positive findings, and therefore improve the identification of patients with the target clinical findings in EHRs. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Measurement of dragging of inertial frames and gravitomagnetic field using laser-ranged satellites.

    Science.gov (United States)

    Ciufolini, I.; Lucchesi, D.; Vespe, F.; Mandiello, A.

    1996-05-01

    By analysing the observations of the orbits of the laser-ranged satellites LAGEOS and LAGEOS II, using the program GEODYN, the authors have obtained the first direct measurement of the Lense-Thirring effect, or dragging of inertial frames and the first direct experimental evidence for the gravitomagnetic field. The accuracy of their measurement is of about 30%.

  9. Expanding the dynamic measurement range for polymeric nanoparticle pH sensors

    DEFF Research Database (Denmark)

    Sun, Honghao; Almdal, Kristoffer; Andresen, Thomas Lars

    2011-01-01

    Conventional optical nanoparticle pH sensors that are designed for ratiometric measurements in cells have been based on utilizing one sensor fluorophore and one reference fluorophore in each nanoparticle, which results in a relatively narrow dynamic measurement range. This results in substantial...

  10. Variation in measurements of range of motion : a study in reflex sympathetic dystrophy patients

    NARCIS (Netherlands)

    Geertzen, J.H.B.; Dijkstra, P.U.; Stewart, R.E; Groothoff, J.W.; ten Duis, H J; Eisma, W.H.

    1998-01-01

    Objective: To quantify the amount of variation attributed to different sources of variation in measurement results of upper extremity range of motion, and to estimate the smallest detectable difference (SDD) between measurements in reflex sympathetic dystrophy (RSD) patients. Design: Two observers

  11. Clinical measurement of range of motion. Review of goniometry emphasizing reliability and validity.

    Science.gov (United States)

    Gajdosik, R L; Bohannon, R W

    1987-12-01

    Clinical measurement of range of motion is a fundamental evaluation procedure with ubiquitous application in physical therapy. Objective measurements of ROM and correct interpretation of the measurement results can have a substantial impact on the development of the scientific basis of therapeutic interventions. The purpose of this article is to review the related literature on the reliability and validity of goniometric measurements of the extremities. Special emphasis is placed on how the reliability of goniometry is influenced by instrumentation and procedures, differences among joint actions and body regions, passive versus active measurements, intratester versus intertester measurements, and different patient types. Our discussion of validity encourages objective interpretation of the meaning of ROM measurements in light of the purposes and the limitations of goniometry. We conclude that clinicians should adopt standardized methods of testing and should interpret and report goniometric results as ROM measurements only, not as measurements of factors that may affect ROM.

  12. Simultaneous measurement of spectra at multiple ranges using a single spectrometer.

    Science.gov (United States)

    Lienert, Barry; Porter, John; Sharma, Shiv K

    2009-08-20

    We have designed and built an instrument having the capability to measure and display spectra at multiple ranges near simultaneously in real time. An excitation laser beam is oriented parallel to and offset from the axis of the light collection optics. The image of the laser beam is then displaced with range. Multiple optical fibers collect the displaced images at different ranges. The output ends of these fibers are positioned vertically along the input slit of a spectrometer that disperses the light from each fiber along different rows of the spectrometer's two-dimensional detector array. The detector array rows then give an immediate visual comparison of spectra at different ranges. A small prototype of this system covering a range from 3 to 13 m has been built. It has been successfully tested using containers holding two distinct fluorescent dyes. Numerical simulations indicate that the technique can be extended to longer-range systems.

  13. Near Field HF Antenna Pattern Measurement Method Using an Antenna Pattern Range

    Science.gov (United States)

    2015-12-01

    TECHNICAL REPORT 3006 December 2015 Near-Field HF Antenna Pattern Measurement Method Using an Antenna Pattern Range Ani Siripuram Michael Daly...link budget. This report focuses on computing absolute gain for HF antennas measured on the APR. Recent research efforts by SSC Pacific’s Applied...Electromagnetics Branch (Code 52250) show that the APR extends to accurate measurement of normalized far-field radiation patterns of HF antennas. The

  14. Accuracy and Reliability of Visual Inspection and Smartphone Applications for Measuring Finger Range of Motion.

    Science.gov (United States)

    Lee, Hannah H; St Louis, Kwesi; Fowler, John R

    2018-01-08

    Measurement of finger range of motion is critical in clinical settings, especially for outcome analysis, clinical decision making, and rehabilitation/disability assessment. Although goniometer measurement is clinically considered the gold standard, its accuracy compared with the true radiographic measurements of the joint angles remains questionable. The authors compared 3 smartphone applications and visual inspection measurements of the finger joints with the radiographic measurements and determined interrater reliability for these measurement tools. A finger was held in place using an aluminum-alloy splint, and a fluoroscopic image was acquired by a mini C-arm. An independent observer measured each joint flexion angle of the fluoroscopic image using a universal handheld goniometer, and this was used as the reference. Finger joint flexion angles were then independently measured by 3 observers using 3 different smartphone applications. In addition, visual inspection was used to estimate the flexion angles of finger joints. The results of this study suggest that all 3 smartphone measurement tools, as well as visual inspection, agree and correlate well with the reference fluoroscopic image measurement. Average differences between the fluoroscopic image measurements with the measured angles using the tools studied ranged from 9.4° to 12.2°. The mean correlation coefficients for each smartphone application exceeded 0.7. Overall interrater reliabilities were similar, with the interclass correlation coefficient being greater than 0.9 for all of the measurement tools. These data suggest that new smartphone applications hold promise for providing accurate and reliable measures of range of motion. [Orthopedics. 201x; xx(x):xx-xx.]. Copyright 2018, SLACK Incorporated.

  15. An impedance bridge measuring the capacitance ratio in the high frequency range up to 1 MHz

    Science.gov (United States)

    Bee Kim, Dan; Kew Lee, Hyung; Kim, Wan-Seop

    2017-02-01

    This paper describes a 2-terminal-pair impedance bridge, measuring the capacitance ratio in the high frequency range up to 1 MHz. The bridge was configured with two voltage sources and a phase control unit which enabled the bridge balance by synchronizing the voltage sources with an enhanced phase resolution. Without employing the transformers such as inductive voltage divider, injection and detection transformers, etc, the bridge system is quite simple to set up, and the balance procedure is quick and easy. Using this dual-source coaxial bridge, the 1:1 and 10:1 capacitance ratios were measured with 1 pF-1 nF capacitors in the frequency range from 1 kHz to 1 MHz. The measurement values obtained by the dual-source bridge were then compared with reference values measured using a commercial precision capacitance bridge of AH2700A, the Z-matrix method developed by ourselves, and the 4-terminal-pair coaxial bridge by the Czech Metrological Institute. All the measurements agreed within the reference uncertainty range of an order of 10-6-10-5, proving the bridge ability as a trustworthy tool for measuring the capacitance ratio in the high frequency range.

  16. Propagation Loss Measurements at 400 Hertz in the BIFI Range Using a Towed Source.

    Science.gov (United States)

    1971-01-27

    series using the BIFI Range (Reference 1) located between Block Island, Rhode Island and Fishers Island, New York. Three types of acoustic tests were... Colossus theoretical predictions (Reference 7). The agreement is fairly good; it is apparent, howev er, that the Colossus predictions do not take into...given in reference 11. - Propagation loss was measured as a function of range and the results compared to the Colossus predictions’ (reference 7). The

  17. Varying the item format improved the range of measurement in patient-reported outcome measures assessing physical function

    DEFF Research Database (Denmark)

    Liegl, Gregor; Gandek, Barbara; Fischer, H. Felix

    2017-01-01

    Background: Physical function (PF) is a core patient-reported outcome domain in clinical trials in rheumatic diseases. Frequently used PF measures have ceiling effects, leading to large sample size requirements and low sensitivity to change. In most of these instruments, the response category...... easy, increases the range of precise measurement of self-reported PF. Methods: Three five-item PF short forms were constructed from the Patient-Reported Outcomes Measurement Information System (PROMIS®) wave 1 data. All forms included the same physical activities but varied in item stem and response...... precision between the short forms using different item formats. Results: Sufficient unidimensionality of all short-form items and the original PF item bank was supported. Compared to formats A and B, format C increased the range of reliable measurement by about 0.5 standard deviations on the positive side...

  18. Long-Range Channel Measurements on Small Terminal Antennas Using Optics

    DEFF Research Database (Denmark)

    Yanakiev, Boyan; Nielsen, Jesper Ødum; Christensen, Morten

    2012-01-01

    In this paper, details are given on a novel measurement device for radio propagation-channel measurements. To avoid measurement errors due to the conductive cables on small terminal antennas, as well as to improve the handling of the prototypes under investigation, an optical measurement device has...... been developed. It utilizes thin, light, and flexible glass fibers as opposed to heavy, stiff, and conductive coaxial cables. This paper looks at the various system parameters such as overall gain, noise figure, and dynamic range and compares the solution to other methods. An estimate of the device...

  19. Accurate Measurement of First Metatarsophalangeal Range of Motion in Patients With Hallux Rigidus.

    Science.gov (United States)

    Vulcano, Ettore; Tracey, Joseph A; Myerson, Mark S

    2016-05-01

    The reliability of range of motion (ROM) measurements has not been established for the hallux metatarsophalangeal (MTP) joint in patients with hallux rigidus. The aim of the present study was to prospectively assess the clinical versus radiographic difference in ROM of the arthritic hallux MTP joint. One hundred consecutive patients who presented with any grade of hallux rigidus were included in this prospective study to determine the hallux MTP range of motion. Clinical range of motion using a goniometer and radiographic range of motion on dynamic x-rays was recorded. The mean difference between clinical and radiographic dorsiflexion was 13 degrees (P dorsiflexion was equal to or less than radiographically measured dorsiflexion. The difference was significantly greater in patients with a clinical dorsiflexion of less than 30 degrees than in patients with 30 degrees or more. Radiographic measurement of hallux dorsiflexion had an excellent intra- and interobserver reliability. We describe a reliable, reproducible, and straightforward method of measuring hallux MTP ROM that improved upon measuring clinical ROM. Level II, prospective comparative study. © The Author(s) 2015.

  20. Human-Induced Effects on RSS Ranging Measurements for Cooperative Positioning

    OpenAIRE

    Francescantonio Della Rosa; Mauro Pelosi; Jari Nurmi

    2012-01-01

    We present experimental evaluations of human-induced perturbations on received-signal-strength-(RSS-) based ranging measurements for cooperative mobile positioning. To the best of our knowledge, this work is the first attempt to gain insight and understand the impact of both body loss and hand grip on the RSS for enhancing proximity measurements among neighbouring devices in cooperative scenarios. Our main contribution is represented by experimental investigations. Analysis of the errors intr...

  1. Intersatellite laser ranging with homodyne optical phase locking for Space Advanced Gravity Measurements mission.

    Science.gov (United States)

    Yeh, Hsien-Chi; Yan, Qi-Zhong; Liang, Yu-Rong; Wang, Ying; Luo, Jun

    2011-04-01

    In this paper, we present the scheme and the preliminary results of an intersatellite laser ranging system that is designed for the Earth's gravity recovery mission proposed in China, called Space Advanced Gravity Measurements (SAGM). The proposed intersatellite distance is about 100 km and the precision of inter-satellite range monitoring is 10 nm/Hz(1/2) at 0.1 Hz. To meet the needs, we designed a transponder-type intersatellite laser ranging system by using a homodyne optical phase locking technique, which is different from the heterodyne optical phase-locked loop used in GRACE follow-on mission. Since an ultrastable oscillator is unnecessary in the homodyne phase-locked loop, the measurement error caused by the frequency instability of the ultrastable oscillator need not be taken into account. In the preliminary study, a heterodyne interferometer with 10-m baseline (measurement arm-length) was built up to demonstrate the validity of the measurement scheme. The measurement results show that a resolution of displacement measurement of about 3.2 nm had been achieved. © 2011 American Institute of Physics

  2. Evaluation of Soil Loss and Erosion Control Measures on Ranges and Range Structures at Installations in Temperate Climates

    Science.gov (United States)

    2006-06-01

    classified as discontinu- ous loess on bedrock and are finely textured silty clays and silty loams (Noble et al. 1990). The first visit to Camp...challenge as vegetation reestablishment is diffi- cult on the remaining eroded nutrient -poor soil. Investigations of newly constructed embankments as in...concentrations through range monitoring. Camp Atterbury Soils The soils in this area are classified as discontinuous loess on bedrock. Soil surveys completed

  3. Acoustic absorption measurement of human hair and skin within the audible frequency range.

    Science.gov (United States)

    Katz, B F

    2000-11-01

    Utilizing the two-microphone impedance tube method, the acoustic absorption of human skin and hair is measured in the frequency range 1-6 kHz. Various locations on a number of human subjects are measured to determine if the presence of bone or an air pocket affects the acoustic absorption of human skin. The absorption coefficient of human hair is also measured. Additional techniques are utilized to minimize errors due to sample mounting methods. Techniques are employed to minimize potential errors in sensor and sample locations. The results of these measurements are compared to relevant historical papers on similar investigations. Results for skin measurements compare well with previous work. Measured hair absorption data do not agree with previous work in the area but do coincide with expected trends, which previous works do not.

  4. An extended set-value observer for position estimation using single range measurements

    DEFF Research Database (Denmark)

    Marcal, Jose; Jouffroy, Jerome; Fossen, Thor I.

    of transponders. The knowledge of the bearing of the vehicle and the range measurements from a single location can provide a solution which is sensitive to the trajectory that the vehicle is following, since there is no complete constraint on the position estimate with a single beacon. In this paper...

  5. Polymeric pH nanosensor with extended measurement range bearing octaarginine as cell penetrating peptide

    DEFF Research Database (Denmark)

    Ke, Peng; Sun, Honghao; Liu, Mingxing

    2016-01-01

    A synthetic peptide octaarginine which mimics human immunodeficiency virus-1, Tat protein is used as cell penetrating moiety for new pH nanosensors which demonstrate enhanced cellular uptake and expanded measurement range from pH 3.9 to pH 7.3 by simultaneously incorporating two complemental p...

  6. Spin motion determination of the Envisat satellite through laser ranging measurements from a single pass measured by a single station

    Science.gov (United States)

    Pittet, Jean-Noël; Šilha, Jiří; Schildknecht, Thomas

    2018-02-01

    The Satellite Laser Ranging (SLR) technology is used to accurately determine the position of space objects equipped with so-called retro-reflectors or retro-reflector arrays (RRA). This type of measurement allows to measure the range to the spacecraft with high precision, which leads to determination of very accurate orbits for these targets. Non-active spacecraft, which are not attitude controlled any longer, tend to start to spin or tumble under influence of the external and internal torques and forces. If the return signal is measured for a non-spherical non-active rotating object, the signal in the range residuals with respect to the reference orbit is more complex. For rotating objects the return signal shows an oscillating pattern or patterns caused by the RRA moving around the satellite's centre of mass. This behaviour is projected onto the radial component measured by the SLR. In our work, we demonstrate how the SLR ranging technique from one sensor to a satellite equipped with a RRA can be used to precisely determine its spin motion during one passage. Multiple SLR measurements of one target over time allow to accurately monitor spin motion changes which can be further used for attitude predictions. We show our solutions of the spin motion determined for the non-active ESA satellite Envisat obtained from measurements acquired during years 2013-2015 by the Zimmerwald SLR station, Switzerland. All the necessary parameters are defined for our own so-called point-like model which describes the motion of a point in space around the satellite centre of mass.

  7. The value of forage measurement information in rangeland management. [implementation of satellite data in range management

    Science.gov (United States)

    Lietzke, K. R.

    1975-01-01

    An economic model and simulation are developed to estimate the potential social benefit arising from the use of alternative measurement systems in rangeland management. In order to estimate these benefits, it was necessary to model three separate systems: the range environment, the rangeland manager, and the information system which links the two. The rancher's decision-making behavior is modeled according to sound economic principles. Results indicate substantial potential benefits, particularly when used in assisting management of government-operated ranges; possible annual benefits in this area range from $20 to $46 million, depending upon the system capabilities assumed. Possible annual benefit in privately-managed stocker operations range from $2.8 to $49.5 million, depending upon where actual rancher capabilities lie and what system capabilities are assumed.

  8. High-resolution and wide range displacement measurement based on planar grating

    Science.gov (United States)

    Lin, Jie; Guan, Jian; Wen, Feng; Tan, Jiubin

    2017-12-01

    High/ultra-precision motion measurements for precision translation stages are highly desired in modern manufacturing systems and instruments. In this work, we introduce a wide range three-axis grating encoder with nanometric resolution, which can measure the x-, y- and z-axial translational motions of a stage simultaneously. The grating encoder is composed of a reflective-type planar scale grating with a period of 8 μm and an optical reading head. A planar reference grating, which is the same as the planar scale grating except the length and width, is employed in the optical reading head. The x- and y- directional ±1st order diffractive beams of the planar scale grating interfere with the corresponding diffractive beams of the planar reference grating, forming the measurement signals. The x- and y- directional ±1st order diffractive beams of the two planar gratings propagate against their original incident path, working as the autocollimatic diffractive beams. Therefore, the z-axial measurement range of the proposed grating encoder is greatly enhanced. The x- and y- axial measurement ranges depend on the size of the planar scale grating. To make the grating encoder more compact, a double grating beam-splitting (DGBS) unit and two diffractive optical elements (DOEs) are introduced. The experimental results indicate that the z-axial displacement resolution is as high as 4 nm with an electronic data division card of 80 segments developed by our lab.

  9. Improving the Dynamic Emissivity Measurement Above 1000 K by Extending the Spectral Range

    Science.gov (United States)

    Urban, D.; Krenek, S.; Anhalt, K.; Taubert, D. R.

    2018-01-01

    To improve the dynamic emissivity measurement, which is based on the laser-flash method, an array spectrometer is characterized regarding its spectral radiance responsivity for a spectrally resolved emissivity measurement above 1000 K in the wavelength range between 550 nm and 1100 nm. Influences like dark signals, the nonlinearity of the detector, the size-of-source effect, wavelength calibration and the spectral radiance responsivity of the system are investigated to obtain an uncertainty budget for the spectral radiance and emissivity measurements. Uncertainties for the spectral radiance of lower than a relative 2 % are achieved for wavelengths longer than 550 nm. Finally, the spectral emissivity of a graphite sample was determined in the temperature range between 1000 K and 1700 K, and the experimental data show a good repeatability and agreement with literature data.

  10. LUMOS - A Sensitive and Reliable Optode System for Measuring Dissolved Oxygen in the Nanomolar Range

    DEFF Research Database (Denmark)

    Lehner, Philipp; Larndorfer, Christoph; Garcia-Robledo, Emilio

    2015-01-01

    Most commercially available optical oxygen sensors target the measuring range of 300 to 2 mu mol L-1. However these are not suitable for investigating the nanomolar range which is relevant for many important environmental situations. We therefore developed a miniaturized phase fluorimeter based...... measurement system called the LUMOS (Luminescence Measuring Oxygen Sensor). It consists of a readout device and specialized "sensing chemistry" that relies on commercially available components. The sensor material is based on palladium(II)-5,10,15,20-tetrakis-(2,3,4,5,6-pentafluorphenyl)-porphyrin embedded...... for read out of less sensitive optical oxygen sensors based on the same or similar indicator dyes, for example for monitoring oxygen at physiological conditions. The presented sensor system exhibits lower noise, higher resolution and higher sensitivity than the electrochemical STOX sensor previously used...

  11. LUMOS - A Sensitive and Reliable Optode System for Measuring Dissolved Oxygen in the Nanomolar Range

    Science.gov (United States)

    Lehner, Philipp; Larndorfer, Christoph; Garcia-Robledo, Emilio; Larsen, Morten; Borisov, Sergey M.; Revsbech, Niels-Peter; Glud, Ronnie N.; Canfield, Donald E.; Klimant, Ingo

    2015-01-01

    Most commercially available optical oxygen sensors target the measuring range of 300 to 2 μmol L-1. However these are not suitable for investigating the nanomolar range which is relevant for many important environmental situations. We therefore developed a miniaturized phase fluorimeter based measurement system called the LUMOS (Luminescence Measuring Oxygen Sensor). It consists of a readout device and specialized “sensing chemistry” that relies on commercially available components. The sensor material is based on palladium(II)-5,10,15,20-tetrakis-(2,3,4,5,6-pentafluorphenyl)-porphyrin embedded in a Hyflon AD 60 polymer matrix and has a KSV of 6.25 x 10-3 ppmv-1. The applicable measurement range is from 1000 nM down to a detection limit of 0.5 nM. A second sensor material based on the platinum(II) analogue of the porphyrin is spectrally compatible with the readout device and has a measurement range of 20 μM down to 10 nM. The LUMOS device is a dedicated system optimized for a high signal to noise ratio, but in principle any phase flourimeter can be adapted to act as a readout device for the highly sensitive and robust sensing chemistry. Vise versa, the LUMOS fluorimeter can be used for read out of less sensitive optical oxygen sensors based on the same or similar indicator dyes, for example for monitoring oxygen at physiological conditions. The presented sensor system exhibits lower noise, higher resolution and higher sensitivity than the electrochemical STOX sensor previously used to measure nanomolar oxygen concentrations. Oxygen contamination in common sample containers has been investigated and microbial or enzymatic oxygen consumption at nanomolar concentrations is presented. PMID:26029920

  12. Comparing range data across the slow-time dimension to correct motion measurement errors beyond the range resolution of a synthetic aperture radar

    Science.gov (United States)

    Doerry, Armin W.; Heard, Freddie E.; Cordaro, J. Thomas

    2010-08-17

    Motion measurement errors that extend beyond the range resolution of a synthetic aperture radar (SAR) can be corrected by effectively decreasing the range resolution of the SAR in order to permit measurement of the error. Range profiles can be compared across the slow-time dimension of the input data in order to estimate the error. Once the error has been determined, appropriate frequency and phase correction can be applied to the uncompressed input data, after which range and azimuth compression can be performed to produce a desired SAR image.

  13. Knee range of motion: reliability and agreement of 3 measurement methods.

    Science.gov (United States)

    Peters, Paul G; Herbenick, Michael A; Anloague, Philip A; Markert, Ronald J; Rubino, L Joseph

    2011-12-01

    We conducted a study to compare 3 methods of measuring knee range of motion: visual estimation by physicians, hand goniometry by physical therapists, and radiographic goniometry. We hypothesized that reliability would be high within and across all techniques. We found intrarater and interrater reliability to be satisfactory for visual estimation, hand goniometry, and radiographic goniometry. Interrater reliability across methods did not agree satisfactorily. Between-methods differences in estimating knee range of motion may result from variations in technique among physicians and physical therapists.

  14. Fluorescent Protein Based FRET Pairs with Improved Dynamic Range for Fluorescence Lifetime Measurements

    Science.gov (United States)

    George Abraham, Bobin; Sarkisyan, Karen S.; Mishin, Alexander S.; Santala, Ville; Tkachenko, Nikolai V.; Karp, Matti

    2015-01-01

    Fluorescence Resonance Energy Transfer (FRET) using fluorescent protein variants is widely used to study biochemical processes in living cells. FRET detection by fluorescence lifetime measurements is the most direct and robust method to measure FRET. The traditional cyan-yellow fluorescent protein based FRET pairs are getting replaced by green-red fluorescent protein variants. The green-red pair enables excitation at a longer wavelength which reduces cellular autofluorescence and phototoxicity while monitoring FRET. Despite the advances in FRET based sensors, the low FRET efficiency and dynamic range still complicates their use in cell biology and high throughput screening. In this paper, we utilized the higher lifetime of NowGFP and screened red fluorescent protein variants to develop FRET pairs with high dynamic range and FRET efficiency. The FRET variations were analyzed by proteolytic activity and detected by steady-state and time-resolved measurements. Based on the results, NowGFP-tdTomato and NowGFP-mRuby2 have shown high potentials as FRET pairs with large fluorescence lifetime dynamic range. The in vitro measurements revealed that the NowGFP-tdTomato has the highest Förster radius for any fluorescent protein based FRET pairs yet used in biological studies. The developed FRET pairs will be useful for designing FRET based sensors and studies employing Fluorescence Lifetime Imaging Microscopy (FLIM). PMID:26237400

  15. Fluorescent Protein Based FRET Pairs with Improved Dynamic Range for Fluorescence Lifetime Measurements.

    Directory of Open Access Journals (Sweden)

    Bobin George Abraham

    Full Text Available Fluorescence Resonance Energy Transfer (FRET using fluorescent protein variants is widely used to study biochemical processes in living cells. FRET detection by fluorescence lifetime measurements is the most direct and robust method to measure FRET. The traditional cyan-yellow fluorescent protein based FRET pairs are getting replaced by green-red fluorescent protein variants. The green-red pair enables excitation at a longer wavelength which reduces cellular autofluorescence and phototoxicity while monitoring FRET. Despite the advances in FRET based sensors, the low FRET efficiency and dynamic range still complicates their use in cell biology and high throughput screening. In this paper, we utilized the higher lifetime of NowGFP and screened red fluorescent protein variants to develop FRET pairs with high dynamic range and FRET efficiency. The FRET variations were analyzed by proteolytic activity and detected by steady-state and time-resolved measurements. Based on the results, NowGFP-tdTomato and NowGFP-mRuby2 have shown high potentials as FRET pairs with large fluorescence lifetime dynamic range. The in vitro measurements revealed that the NowGFP-tdTomato has the highest Förster radius for any fluorescent protein based FRET pairs yet used in biological studies. The developed FRET pairs will be useful for designing FRET based sensors and studies employing Fluorescence Lifetime Imaging Microscopy (FLIM.

  16. Fluorescent Protein Based FRET Pairs with Improved Dynamic Range for Fluorescence Lifetime Measurements.

    Science.gov (United States)

    George Abraham, Bobin; Sarkisyan, Karen S; Mishin, Alexander S; Santala, Ville; Tkachenko, Nikolai V; Karp, Matti

    2015-01-01

    Fluorescence Resonance Energy Transfer (FRET) using fluorescent protein variants is widely used to study biochemical processes in living cells. FRET detection by fluorescence lifetime measurements is the most direct and robust method to measure FRET. The traditional cyan-yellow fluorescent protein based FRET pairs are getting replaced by green-red fluorescent protein variants. The green-red pair enables excitation at a longer wavelength which reduces cellular autofluorescence and phototoxicity while monitoring FRET. Despite the advances in FRET based sensors, the low FRET efficiency and dynamic range still complicates their use in cell biology and high throughput screening. In this paper, we utilized the higher lifetime of NowGFP and screened red fluorescent protein variants to develop FRET pairs with high dynamic range and FRET efficiency. The FRET variations were analyzed by proteolytic activity and detected by steady-state and time-resolved measurements. Based on the results, NowGFP-tdTomato and NowGFP-mRuby2 have shown high potentials as FRET pairs with large fluorescence lifetime dynamic range. The in vitro measurements revealed that the NowGFP-tdTomato has the highest Förster radius for any fluorescent protein based FRET pairs yet used in biological studies. The developed FRET pairs will be useful for designing FRET based sensors and studies employing Fluorescence Lifetime Imaging Microscopy (FLIM).

  17. Spatiotemporal treadmill gait measurements using a laser range scanner: feasibility study of the healthy young adults.

    Science.gov (United States)

    Tanabe, S; Ii, T; Koyama, S; Saitoh, E; Itoh, N; Ohtsuka, K; Katoh, Y; Shimizu, A; Tomita, Y

    2017-04-01

    Spatio-temporal parameters are typically used for gait analysis. Although these parameters are measured by sophisticated systems such as 3D motion capture system or optoelectronic bars, these systems cannot be deployed easily because of their high costs, large space requirements and elaborate set-up. The purpose of this study is to develope a system for measuring spatiotemporal gait parameters using a laser range scanner during treadmill gait. To calculate accurate spatiotemporal parameters, the differences between the laser range scanner measured values and the reference values obtained from a 3D motion capture system were investigated in thirty subjects. From measurements in time and position at foot contact/off, adjustments to compensate for the differences in time and position were derived. Then, to determine the validity of the proposed system, values from the proposed system and the reference system were compared in four additional subjects. The results indicate that the data from the laser range scanner demonstrate certain differences in time and position compared with reference values. However, when compensation values were introduced, each spatiotemporal parameter correlated well with the reference values. This newer system is smaller, is easier to deploy and requires less training than the 3D motion capture system.

  18. As Interfaces entre Empreendedorismo Social, Negócios Sociais e Redes Sociais no Campo Social

    Directory of Open Access Journals (Sweden)

    Maria de Fátima da Silva

    2015-08-01

    Full Text Available http://dx.doi.org/10.5007/2175-8077.2015v17n42p121 Este ensaio discute os conceitos do empreendedorismo social, dos negócios sociais e das redes sociais no enfrentamento das demandas sociais, respondendo à pergunta: há interfaces entre esses conceitos? A busca pela mudança social tem no empreendedorismo social, nos negócios sociais e nas redes sociais a possibilidade de gerar ações inovadoras por organizações que atuam tanto no setor público como no privado, com o objetivo de promover a transformação social. As interfaces podem contribuir para a construção do campo da gestão social na medida em que a ação empreendedora no desenvolvimento dos negócios sociais intensifica-se com as redes sociais. O debate dessas ideias sugere a abertura de novos caminhos que possam contribuir para o enfrentamento dos problemas sociais.

  19. Is goniometry suitable for measuring ankle range of motion in female ballet dancers? An initial comparison with radiographic measurement.

    Science.gov (United States)

    Russell, Jeffrey A; Shave, Ruth M; Kruse, David W; Nevill, Alan M; Koutedakis, Yiannis; Wyon, Matthew A

    2011-06-01

    Female ballet dancers require extreme ankle motion to attain the demi-plié (weight-bearing full dorsiflexion [DF]) and en pointe (weight-bearing full plantar flexion [PF]) positions of ballet. However, techniques for assessing this amount of motion have not yet received sufficient scientific scrutiny. Therefore, the purpose of this study was to examine possible differences between weight-bearing goniometric and radiographic ankle range of motion measurements in female ballet dancers. Ankle range of motion in 8 experienced female ballet dancers was assessed by goniometry and 2 radiographic measurement methods. The latter were performed on 3 mediolateral x-rays, in demi-plié, neutral, and en pointe positions; one of them used the same landmarks as goniometry. DF values were not significantly different among the methods, but PF values were (P ballet dancers and suggest that goniometry may not be ideal for assessing ankle range of motion in these individuals. Therefore, further research is needed to standardize how DF and PF are measured in ballet dancers. Diagnostic, Level I.

  20. Electron probe microanalysis (EPMA) measurement of thin-film thickness in the nanometre range.

    Science.gov (United States)

    Procop, M; Radtke, M; Krumrey, M; Hasche, K; Schädlich, S; Frank, W

    2002-10-01

    The thickness of thin films of platinum and nickel on fused silica and silicon substrates has been determined by EPMA using the commercial software STRATAGEM for calculation of film thickness. Film thickness ranged in the order 10 nm. An attempt was made to estimate the confidence range of the method by comparison with results from other methods of analysis. The data show that in addition to the uncertainty of the spectral intensity measurement and the complicated fitting routine, systematic deviation caused by the underlying model should be added. The scattering in the results from other methods does not enable specification of a range of uncertainty, but deviations from the real thickness are estimated to be less than 20%.

  1. A Non-Contact Measurement System for the Range of Motion of the Hand

    Directory of Open Access Journals (Sweden)

    Trieu Pham

    2015-07-01

    Full Text Available An accurate and standardised tool to measure the active range of motion (ROM of the hand is essential to any progressive assessment scenario in hand therapy practice. Goniometers are widely used in clinical settings for measuring the ROM of the hand. However, such measurements have limitations with regard to inter-rater and intra-rater reliability and involve direct physical contact with the hand, possibly increasing the risk of transmitting infections. The system proposed in this paper is the first non-contact measurement system utilising Intel Perceptual Technology and a Senz3D Camera for measuring phalangeal joint angles. To enhance the accuracy of the system, we developed a new approach to achieve the total active movement without measuring three joint angles individually. An equation between the actual spacial position and measurement value of the proximal inter-phalangeal joint was established through the measurement values of the total active movement, so that its actual position can be inferred. Verified by computer simulations, experimental results demonstrated a significant improvement in the calculation of the total active movement and successfully recovered the actual position of the proximal inter-phalangeal joint angles. A trial that was conducted to examine the clinical applicability of the system involving 40 healthy subjects confirmed the practicability and consistency in the proposed system. The time efficiency conveyed a stronger argument for this system to replace the current practice of using goniometers.

  2. Measuring finite-range phase coherence in an optical lattice using Talbot interferometry

    Science.gov (United States)

    Santra, Bodhaditya; Baals, Christian; Labouvie, Ralf; Bhattacherjee, Aranya B.; Pelster, Axel; Ott, Herwig

    2017-06-01

    One of the important goals of present research is to control and manipulate coherence in a broad variety of systems, such as semiconductor spintronics, biological photosynthetic systems, superconducting qubits and complex atomic networks. Over the past decades, interferometry of atoms and molecules has proven to be a powerful tool to explore coherence. Here we demonstrate a near-field interferometer based on the Talbot effect, which allows us to measure finite-range phase coherence of ultracold atoms in an optical lattice. We apply this interferometer to study the build-up of phase coherence after a quantum quench of a Bose-Einstein condensate residing in a one-dimensional optical lattice. Our technique of measuring finite-range phase coherence is generic, easy to adopt and can be applied in practically all lattice experiments without further modifications.

  3. Wide-range dynamic strain measurements based on K-BOTDA and frequency-agile technique

    Science.gov (United States)

    Zhou, Dengwang; Dong, Yongkang; Wang, Benzhang; Zhang, Hongying; Lu, Zhiwei

    2017-04-01

    We propose and demonstrate a novel fast Brillouin optical time-domain analysis system using the coefficient K spectrum which is defined as the ratio of phase-shift and gain of Brillouin amplification, where K features linear response, immune to the variation of pump power and a wide measure range. For a 30ns-square pump pulse, the frequency span of K spectrum can reach up to 200MHz. In dynamic strain experiment, a multi-slope assisted K-BOTDA with the measured strain of 5358.3μɛ and the vibration frequency of 6.01Hz and 12.05Hz are demonstrated.

  4. [Measurement of the knee range of motion: standard goniometer or smartphone?].

    Science.gov (United States)

    Rwakabayiza, Sylvia; Pereira, Luis Carlos; Lécureux, Estelle; Jolles-Haeberli, Brigitte

    2013-12-18

    Universal standard goniometer is an essential tool to measure articulations' range of motion (ROM). In this time of technological advances and increasing use of smartphones, new measurement's tools appear as specific smartphone applications. This article compares the iOS application "Knee Goniometer" with universal standard goniometer to assess knee ROM. To our knowledge, this is the first study that uses a goniometer application in a clinical context. The purpose of this study is to determine if this application could be used in clinical practice.

  5. Human-Induced Effects on RSS Ranging Measurements for Cooperative Positioning

    DEFF Research Database (Denmark)

    Della Rosa, Francescantonio; Pelosi, Mauro; Nurmi, Jari

    2012-01-01

    We present experimental evaluations of human-induced perturbations on received-signal-strength-(RSS-) based ranging measurements for cooperative mobile positioning. To the best of our knowledge, this work is the first attempt to gain insight and understand the impact of both body loss and hand grip...... on the RSS for enhancing proximity measurements among neighbouring devices in cooperative scenarios. Our main contribution is represented by experimental investigations. Analysis of the errors introduced in the distance estimation using path-loss-based methods has been carried out. Moreover, the exploitation...

  6. Repeatability of Contour Method Residual Stress Measurements for a Range of Material, Process, and Geometry (Preprint)

    Science.gov (United States)

    2017-09-19

    titanium, and nickel, reflecting key industrial alloys . The set of conditions also includes a range of geometry, including plate, disk, and...for measurements. 2.2.3. Titanium Electron Beam Welded Plate Titanium alloy electron beam (EB) welded plate specimens were fabricated using one...right to use , modify, reproduce, release, perform, display, or disclose the work. 14. ABSTRACT (Maximum 200 words) This paper examines precision of

  7. Measurement of the short-range attractive force between Ge plates using a torsion balance

    OpenAIRE

    Kim, W. J.; Sushkov, A. O.; Dalvit, D. A. R.; Lamoreaux, S. K.

    2008-01-01

    We have measured the short-range attractive force between crystalline Ge plates, and found contributions from both the Casimir force and an electrical force possibly generated by surface patch potentials. Using a model of surface patch effects that generates an additional force due to a distance dependence of the apparent contact potential, the electrical force was parameterized using data at distances where the Casimir force is relatively small. Extrapolating this model, to provide a correct...

  8. Validity and reliability of using photography for measuring knee range of motion: a methodological study

    OpenAIRE

    Adie Sam; Ko Victoria; Naylor Justine M; Gaskin Clive; Walker Richard; Harris Ian A; Mittal Rajat

    2011-01-01

    Abstract Background The clinimetric properties of knee goniometry are essential to appreciate in light of its extensive use in the orthopaedic and rehabilitative communities. Intra-observer reliability is thought to be satisfactory, but the validity and inter-rater reliability of knee goniometry often demonstrate unacceptable levels of variation. This study tests the validity and reliability of measuring knee range of motion using goniometry and photographic records. Methods Design: Methodolo...

  9. Comparison of linear gain and wide dynamic range compression hearing aid circuits II: aided loudness measures.

    Science.gov (United States)

    Jenstad, L M; Pumford, J; Seewald, R C; Cornelisse, L E

    2000-02-01

    The goal of this study was to test the theoretical advantages of a single-channel wide dynamic range compression (WDRC) circuit fitted using the DSL method for increased dynamic range and normalized loudness growth. Ten adolescents and young adults with moderate to severe sensorineural hearing loss were fitted monaurally with the Siemens Viva 2 Pro behind-the-ear instrument set to DSL 4.0 targets for both linear gain and WDRC processing. Threshold, upper limit of comfort and loudness growth were measured in the unaided, linear gain and WDRC conditions for warble tones, environmental sounds and speech. Twelve adult listeners with normal hearing also were tested monaurally in the unaided condition to provide normative data for comparison purposes. The WDRC hearing aid provided a greater input dynamic range than the linear circuit for all stimuli. The dynamic range was normalized for more subjects with the WDRC than the linear hearing aid. In addition, exponential loudness growth functions fitted to the loudness growth data showed that, on average, loudness growth was more normalized with the WDRC hearing aid fitted to DSL[i/o] targets than the linear hearing aid fitted to DSL[i/o] targets. WDRC processing, fitted using the DSL[i/o] method, has potential applications in hearing aid fittings for listeners with moderate to severe hearing loss because it provides an audible, comfortable and tolerable amplified signal across a wider range of inputs than linear gain processing, without the need for volume control adjustments.

  10. Reliability of speaking and maximum voice range measures in screening for dysphonia.

    Science.gov (United States)

    Ma, Estella; Robertson, Jennie; Radford, Claire; Vagne, Sarah; El-Halabi, Ruba; Yiu, Edwin

    2007-07-01

    Speech range profile (SRP) is a graphical display of frequency-intensity occurring interactions during functional speech activity. Few studies have suggested the potential clinical applications of SRP. However, these studies are limited to qualitative case comparisons and vocally healthy participants. The present study aimed to examine the effects of voice disorders on speaking and maximum voice ranges in a group of vocally untrained women. It also aimed to examine whether voice limit measures derived from SRP were as sensitive as those derived from voice range profile (VRP) in distinguishing dysphonic from healthy voices. Ninety dysphonic women with laryngeal pathologies and 35 women with normal voices, who served as controls, participated in this study. Each subject recorded a VRP for her physiological vocal limits. In addition, each subject read aloud the "North Wind and the Sun" passage to record SRP. All the recordings were captured and analyzed by Soundswell's computerized real-time phonetogram Phog 1.0 (Hitech Development AB, Täby, Sweden). The SRPs and the VRPs were compared between the two groups of subjects. Univariate analysis results demonstrated that individual SRP measures were less sensitive than the corresponding VRP measures in discriminating dysphonic from normal voices. However, stepwise logistic regression analyses revealed that the combination of only two SRP measures was almost as effective as a combination of three VRP measures in predicting the presence of dysphonia (overall prediction accuracy: 93.6% for SRP vs 96.0% for VRP). These results suggest that in a busy clinic where quick voice screening results are desirable, SRP can be an acceptable alternate procedure to VRP.

  11. Measurement of soil water potential over an extended range by polymer tensiometers: comparison with other instruments

    Science.gov (United States)

    van der Ploeg, M. J.; Gooren, H. P.; Hoogendam, R. C.; Bakker, G.; Huiskes, C.; Koopal, L. K.; Kruidhof, H.; de Rooij, G. H.

    2007-12-01

    In water scarce areas, plant growth and productivity can be severely hampered by irregular precipitation and overall water shortage. Root water uptake is mainly driven by matric potential gradients, but measurement of soil water matric potential is limited by the measurement range of water-filled tensiometers (-0.085 MPa). Other measurement techniques indirectly measure soil water potential by converting soil water content with the use of the water retention curve. In dry soils, the water content measurements may become insensitive to small variations, and consequently this conversion may lead to large errors. We developed a polymer tensiometer (POT) that is able to measure matric potentials down to -2.0 MPa. The POT consists of a solid ceramic, a stainless steel cup and a pressure transducer. The ceramic consist of a support layer and a membrane with 2 nm pore-size to prevent polymer leakage. Between the ceramic membrane and the pressure transducer a tiny chamber is located, which contains the polymer solution. The polymer's osmotic potential strongly reduces the total water potential inside the polymer tensiometer, which causes build-up of osmotic pressure. Hence, the water in the polymer tensiometer will cavitate at a much lower matric potential than the nearly pure water in a conventional tensiometer. Direct observation of the potential of soil water at different locations in the root-system will yield knowledge about the ability of a plant to take up the water under conditions of water shortage or salinity stress. With this knowledge it will be possible to adjust existing unsaturated flow models accounting for root water uptake. We tested 8 POTs in an experimental setup, where we compared matric potential measurements to TDR water content measurements, matric potentials derived from measured water contents, and matric potentials measured by water-filled tensiometers. The experimental setup consisted of two evaporation boxes, one filled with sand (97.6% sand, 1

  12. Dynamic Data Filtering of Long-Range Doppler LiDAR Wind Speed Measurements

    Directory of Open Access Journals (Sweden)

    Hauke Beck

    2017-06-01

    Full Text Available Doppler LiDARs have become flexible and versatile remote sensing devices for wind energy applications. The possibility to measure radial wind speed components contemporaneously at multiple distances is an advantage with respect to meteorological masts. However, these measurements must be filtered due to the measurement geometry, hard targets and atmospheric conditions. To ensure a maximum data availability while producing low measurement errors, we introduce a dynamic data filter approach that conditionally decouples the dependency of data availability with increasing range. The new filter approach is based on the assumption of self-similarity, that has not been used so far for LiDAR data filtering. We tested the accuracy of the dynamic data filter approach together with other commonly used filter approaches, from research and industry applications. This has been done with data from a long-range pulsed LiDAR installed at the offshore wind farm ‘alpha ventus’. There, an ultrasonic anemometer located approximately 2.8 km from the LiDAR was used as reference. The analysis of around 1.5 weeks of data shows, that the error of mean radial velocity can be minimised for wake and free stream conditions.

  13. Average Neutron Total Cross Sections in the Unresolved Energy Range From ORELA High Resolutio Transmission Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Derrien, H

    2004-05-27

    Average values of the neutron total cross sections of {sup 233}U, {sup 235}U, {sup 238}U, and {sup 239}Pu have been obtained in the unresolved resonance energy range from high-resolution transmission measurements performed at ORELA in the past two decades. The cross sections were generated by correcting the effective total cross sections for the self-shielding effects due to the resonance structure of the data. The self-shielding factors were found by calculating the effective and true cross sections with the computer code SAMMY for the same Doppler and resolution conditions as for the transmission measurements, using an appropriate set of resonance parameters. Our results are compared to results of previous measurements and to the current ENDF/B-VI data.

  14. Measurements and correlations of turbulent burning velocities over wide ranges of fuels and elevated pressures

    KAUST Repository

    Bradley, Derek

    2013-01-01

    The implosion technique has been used to extend measurements of turbulent burning velocities over greater ranges of fuels and pressures. Measurements have been made up to 3.5 MPa and at strain rate Markstein numbers as low as 23. The implosion technique, with spark ignition at two opposite wall positions within a fan-stirred spherical bomb is capable of measuring turbulent burning velocities, at higher pressures than is possible with central ignition. Pressure records and schlieren high speed photography define the rate of burning and the smoothed area of the flame front. The first aim of the study was to extend the previous measurements with ethanol and propane-air, with further measurements over wider ranges of fuels and equivalence ratios with mixtures of hydrogen, methane, 10% hydrogen-90% methane, toluene, and i-octane, with air. The second aim was to study further the low turbulence regime in which turbulent burning co-exists with laminar flame instabilities. Correlations are presented of turbulent burning velocity normalised by the effective rms turbulent velocity acting on the flame front, ut=u0k , with the Karlovitz stretch factor, K, for different strain rate Markstein numbers, a decrease in which increases ut=u0k . Experimental correlations are presented for the present measurements, combined with previous ones. Different burning regimes are also identified, extending from that of mixed turbulence/laminar instability at low values of K to that at high values of K, in which ut=u0k is gradually reduced due to increasing localised flame extinctions. © 2012 The Combustion Institute.

  15. Feasibility of RACT for 3D dose measurement and range verification in a water phantom.

    Science.gov (United States)

    Alsanea, Fahed; Moskvin, Vadim; Stantz, Keith M

    2015-02-01

    The objective of this study is to establish the feasibility of using radiation-induced acoustics to measure the range and Bragg peak dose from a pulsed proton beam. Simulation studies implementing a prototype scanner design based on computed tomographic methods were performed to investigate the sensitivity to proton range and integral dose. Derived from thermodynamic wave equation, the pressure signals generated from the dose deposited from a pulsed proton beam with a 1 cm lateral beam width and a range of 16, 20, and 27 cm in water using Monte Carlo methods were simulated. The resulting dosimetric images were reconstructed implementing a 3D filtered backprojection algorithm and the pressure signals acquired from a 71-transducer array with a cylindrical geometry (30 × 40 cm) rotated over 2π about its central axis. Dependencies on the detector bandwidth and proton beam pulse width were performed, after which, different noise levels were added to the detector signals (using 1 μs pulse width and a 0.5 MHz cutoff frequency/hydrophone) to investigate the statistical and systematic errors in the proton range (at 20 cm) and Bragg peak dose (of 1 cGy). The reconstructed radioacoustic computed tomographic image intensity was shown to be linearly correlated to the dose within the Bragg peak. And, based on noise dependent studies, a detector sensitivity of 38 mPa was necessary to determine the proton range to within 1.0 mm (full-width at half-maximum) (systematic error ionizing radiation-induced acoustics can be used to verify dose distribution and proton range with centi-Gray sensitivity. Realizing this technology into the clinic has the potential to significantly impact beam commissioning, treatment verification during particle beam therapy and image guided techniques.

  16. Sensitivity of physiological emotional measures to odors depends on the product and the pleasantness ranges used

    Directory of Open Access Journals (Sweden)

    Aline Marie Pichon

    2015-12-01

    Full Text Available Emotions are characterized by synchronized changes in several components of an organism. Among them, physiological variations provide energy support for the expression of approach/avoid action tendencies induced by relevant stimuli, while self-reported subjective pleasantness feelings integrate all other emotional components and are plastic.Consequently, emotional responses evoked by odors should be highly differentiated when they are linked to different functions of olfaction (e.g., avoiding environmental hazards. As this differentiation has been observed for contrasted odors (very pleasant or unpleasant, we questioned whether subjective and physiological emotional response indicators could still disentangle subtle affective variations when no clear functional distinction is made (mildly pleasant or unpleasant fragrances. Here, we compared the sensitivity of behavioral and physiological (respiration, skin conductance, facial electromyography (EMG, and heart rate indicators in differentiating odor-elicited emotions in two situations: when a wide range of odor families was presented (e.g., fruity, animal, covering different functional meanings; or in response to a restricted range of products in one particular family (fragrances. Results show clear differences in physiological indicators to odors that display a wide range of reported pleasantness, but these differences almost entirely vanish when fragrances are used even though their subjective pleasantness still differed. Taken together, these results provide valuable information concerning the ability of classic verbal and psychophysiological measures to investigate subtle differences in emotional reactions to a restricted range of similar olfactory stimuli.

  17. Validation of a photography-based goniometry method for measuring joint range of motion.

    Science.gov (United States)

    Blonna, Davide; Zarkadas, Peter C; Fitzsimmons, James S; O'Driscoll, Shawn W

    2012-01-01

    A critical component of evaluating the outcomes after surgery to restore lost elbow motion is the range of motion (ROM) of the elbow. This study examined if digital photography-based goniometry is as accurate and reliable as clinical goniometry for measuring elbow ROM. Instrument validity and reliability for photography-based goniometry were evaluated for a consecutive series of 50 elbow contractures by 4 observers with different levels of elbow experience. Goniometric ROM measurements were taken with the elbows in full extension and full flexion directly in the clinic (once) and from digital photographs (twice in a blinded random manner). Instrument validity for photography-based goniometry was extremely high (intraclass correlation coefficient: extension = 0.98, flexion = 0.96). For extension and flexion measurements by the expert surgeon, systematic error was negligible (0° and 1°, respectively). Limits of agreement were 7° (95% confidence interval [CI], 5° to 9°) and -7° (95% CI, -5° to -9°) for extension and 8° (95% CI, 6° to 10°) and -7° (95% CI, -5° to -9°) for flexion. Interobserver reliability for photography-based goniometry was better than that for clinical goniometry. The least experienced observer's photographic goniometry measurements were closer to the reference measurements than the clinical goniometry measurements. Photography-based goniometry is accurate and reliable for measuring elbow ROM. The photography-based method relied less on observer expertise than clinical goniometry. This validates an objective measure of patient outcome without requiring doctor-patient contact at a tertiary care center, where most contracture surgeries are done. Copyright © 2012 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  18. CFD comparison with centrifugal compressor measurements on a wide operating range

    Directory of Open Access Journals (Sweden)

    Arnou D.

    2013-04-01

    Full Text Available Centrifugal compressors are widely used in industrial applications thanks to their high efficiency. They are able to provide a wide operating range before reaching the flow barrier or surge limits. Performances and range are described by compressor maps obtained experimentally. After a description of performance test rig, this article compares measured centrifugal compressor performances with computational fluid dynamics results. These computations are performed at steady conditions with R134a refrigerant as fluid. Navier-Stokes equations, coupled with k-ε turbulence model, are solved by the commercial software ANSYS-CFX by means of volume finite method. Input conditions are varied in order to calculate several speed lines. Theoretical isentropic efficiency and theoretical surge line are finally compared to experimental data.

  19. Calibration Standards for Surface Topography Measuring Systems down to Nanometric Range

    DEFF Research Database (Denmark)

    Trumpold, H.; De Chiffre, Leonardo; Andreasen, Jan Lasson

    geometry of basic bodies for compression and injection moulding of plastic negatives with different step height, sinusoidal-, triangular and arcuate profiles covering Pt-values from 0.05 µm up to 100 µm and PSm values from 0.8 µm up to 800 µm. For active calibration in Z-direction a small size vertical...... and for the calibration of filters. Existing ISO standards on calibration specimens are inadequate and limited in that they only cover contacting instruments and only partially the measuring ranges for these instruments. The whole range of non-contacting instruments are not covered despite their increasing use...... compression and injection moulded plastic negatives and Ni-negatives have been made from which again Ni-positives were produced. The replication processes showed negligible deviations from the Pt and Pa values compared to the primary standards. An important prerequisite is the cleanliness of the surfaces...

  20. Range Resolved CO2 Atmospheric Backscattering Measurements Using Fiber Lasers and RZPN Code Modulation

    Science.gov (United States)

    Burris, John

    2011-01-01

    We report the use of a return-to- zero (RZPN) pseudo noise modulation technique for making range resolved measurements of CO2 within the planetary boundary layer (PBL) using commercial, off-the-shelf, components. Conventional, range resolved, DIAL measurements require laser pulse widths that are significantly shorter than the desired spatial resolution and necessitate using pulses whose temporal spacing is such that scattered returns from only a single pulse are observed by the receiver at any one time (for the PBL pulse separations must be greater than approximately 20 microseconds). This imposes significant operational limitations when using currently available fiber lasers because of the resulting low duty cycle (less than approximately 0.0005) and consequent low average laser output power. The RZPN modulation technique enables a fiber laser to operate at much higher duty cycles (approaching 0.04) thereby more effectively utilizing the amplifier's output. This increases the counts received by approximately two orders of magnitude. Our approach involves employing two distributed feedback lasers (DFB), each modulated by a different RPZN code, whose outputs are then amplified by a CW fiber amplifier. One laser is tuned to a CO2 absorption line; the other operates offline thereby permitting the simultaneous acquisition of both on and offline signals using independent RZPN codes. This minimizes the impact of atmospheric turbulence on the measurement. The on and offline signals are retrieved by deconvolving the return signal using the appropriate kernels.

  1. Testing accuracy of long-range ultrasonic sensors for olive tree canopy measurements.

    Science.gov (United States)

    Gamarra-Diezma, Juan Luis; Miranda-Fuentes, Antonio; Llorens, Jordi; Cuenca, Andrés; Blanco-Roldán, Gregorio L; Rodríguez-Lizana, Antonio

    2015-01-28

    Ultrasonic sensors are often used to adjust spray volume by allowing the calculation of the crown volume of tree crops. The special conditions of the olive tree require the use of long-range sensors, which are less accurate and faster than the most commonly used sensors. The main objectives of the study were to determine the suitability of the sensor in terms of sound cone determination, angle errors, crosstalk errors and field measurements. Different laboratory tests were performed to check the suitability of a commercial long-range ultrasonic sensor, as were the experimental determination of the sound cone diameter at several distances for several target materials, the determination of the influence of the angle of incidence of the sound wave on the target and distance on the accuracy of measurements for several materials and the determination of the importance of the errors due to interference between sensors for different sensor spacings and distances for two different materials. Furthermore, sensor accuracy was tested under real field conditions. The results show that the studied sensor is appropriate for olive trees because the sound cone is narrower for an olive tree than for the other studied materials, the olive tree canopy does not have a large influence on the sensor accuracy with respect to distance and angle, the interference errors are insignificant for high sensor spacings and the sensor's field distance measurements were deemed sufficiently accurate.

  2. Improving detection range, signal-to-noise ratio, and measurement time through hyperentanglement

    Science.gov (United States)

    Smith, James F.

    2017-07-01

    An atmospheric imaging system based on quantum hyperentanglement has been developed. Hyper-entanglement can increase the maximum detection range of the system by more than a factor of 10, improve the signal-to-noise ratio (SNR) by more than a factor of 10,000, and decrease measurement time. Hyperentanglement refers to entanglement in more than one degree of freedom. A design for creating states hyperentangled in the degrees of freedom polarization, energy-time, orbital angular momentum (OAM), and the radial quantum number is examined. The design helps reduce propagation loss. Figures of merit related to generation and detection efficiencies, the SNR, signal to interference ratio, the measurement time, and phase estimation are provided in closed form. A formula describing how hyperentanglement greatly improves the maximum detection range of the system is derived. Hermite-Gaussian modes, Laguerre-Gaussian (LG) modes, OAM dependence of the LG modes, and mode conversion are discussed. Bell state generation and Bell state measurement, i.e., the ability to distinguish the various Bell states, is discussed. Mathematical and circuit representations of Bell state generation and the Bell state analyzer are provided. Signatures for unique detection of the various Bell states are developed. The formalism permits random noise and entangled or nonentangled sources of interference to be modeled.

  3. Geophysical interpretation of satellite laser ranging measurements of crustal movement in California

    Science.gov (United States)

    Cohen, S. C.

    1984-01-01

    As determined by satellite laser ranging the rate of contraction of a 900 kilometer baseline between sites located near Quincy in northern California and San Diego in southern California is about 61 to 65 mm/yr with a formal uncertainty of about 10 mm/yr. The measured changes in baseline length are a manifestation of the relative motion between the North America and Pacific tectonic plates. This long baseline result is compared to measurements made by more conventional means on shorter baselines. Additional information based on seismicity, geology, and theoretical modelling is also analyzed. Deformation lying within a few tens of kilometers about the major faults in southern California accounts for most, but not all of the observed motion. Further motion is attributable to a broader scale deformation in southern California. Data suggesting crustal movements north of the Garlock fault, in and near the southern Sierra Nevada and local motion at an observatory are also critically reviewed. The best estimates of overall motion indicated by ground observations lie between 40 and 60 mm/yr. This lies within one or two standard deviations of that deduced by satellite ranging but the possibility of some unresolved deficit cannot be dismissed. The long time scale RM2 plate tectonic model of Minster and Jordan predicts a contraction between 47 and 53 mm/yr depending on the extension rate of the Basin and Range. Thus the ground based observations, satellite laser ranging (SLR) results, and RM2 rates differ at about the 10 mm/yr level and are consistent with one another within the data and model uncertainties.

  4. Feasibility of RACT for 3D dose measurement and range verification in a water phantom

    Energy Technology Data Exchange (ETDEWEB)

    Alsanea, Fahed [School of Health Sciences, Purdue University, 550 Stadium Mall Drive, West Lafayette, Indiana 47907-2051 (United States); Moskvin, Vadim [Radiation Oncology, Indiana University School of Medicine, 535 Barnhill Drive, RT 041, Indianapolis, Indiana 46202-5289 (United States); Stantz, Keith M., E-mail: kstantz@purdue.edu [School of Health Sciences, Purdue University, 550 Stadium Mall Drive, West Lafayette, Indiana 47907-2051 and Radiology and Imaging Sciences, Indiana University School of Medicine, 950 West Walnut Street, Indianapolis, Indiana 46202-5289 (United States)

    2015-02-15

    Purpose: The objective of this study is to establish the feasibility of using radiation-induced acoustics to measure the range and Bragg peak dose from a pulsed proton beam. Simulation studies implementing a prototype scanner design based on computed tomographic methods were performed to investigate the sensitivity to proton range and integral dose. Methods: Derived from thermodynamic wave equation, the pressure signals generated from the dose deposited from a pulsed proton beam with a 1 cm lateral beam width and a range of 16, 20, and 27 cm in water using Monte Carlo methods were simulated. The resulting dosimetric images were reconstructed implementing a 3D filtered backprojection algorithm and the pressure signals acquired from a 71-transducer array with a cylindrical geometry (30 × 40 cm) rotated over 2π about its central axis. Dependencies on the detector bandwidth and proton beam pulse width were performed, after which, different noise levels were added to the detector signals (using 1 μs pulse width and a 0.5 MHz cutoff frequency/hydrophone) to investigate the statistical and systematic errors in the proton range (at 20 cm) and Bragg peak dose (of 1 cGy). Results: The reconstructed radioacoustic computed tomographic image intensity was shown to be linearly correlated to the dose within the Bragg peak. And, based on noise dependent studies, a detector sensitivity of 38 mPa was necessary to determine the proton range to within 1.0 mm (full-width at half-maximum) (systematic error < 150 μm) for a 1 cGy Bragg peak dose, where the integral dose within the Bragg peak was measured to within 2%. For existing hydrophone detector sensitivities, a Bragg peak dose of 1.6 cGy is possible. Conclusions: This study demonstrates that computed tomographic scanner based on ionizing radiation-induced acoustics can be used to verify dose distribution and proton range with centi-Gray sensitivity. Realizing this technology into the clinic has the potential to significantly

  5. Measurement based scenario analysis of short-range distribution system planning

    DEFF Research Database (Denmark)

    Chen, Peiyuan; Bak-Jensen, Birgitte; Chen, Zhe

    2009-01-01

    feasible scenarios are performed based on a local distribution system at Støvring in Denmark. Simulation results provide more accurate and insightful information for the decision-maker when using the probabilistic analysis than using the worst-case analysis, so that a better planning can be achieved.......This paper focuses on short-range distribution system planning using a probabilistic approach. Empirical probabilistic distributions of load demand and distributed generations are derived from the historical measurement data and incorporated into the system planning. Simulations with various...

  6. Frequency Comb Driven Raman Transitions in the THz Range: High Precision Isotope Shift Measurements in Ca+

    DEFF Research Database (Denmark)

    Meyer, Steffen

    2017-01-01

    to picoseconds in the previous experiments. For the broad spectrum, the additional effect of group delay dispersion (GDD) has to be taken into account, since the Raman process relies on the coherent interaction of all frequency components of the spectrum, with GDD influencing the relative phase which leads......This thesis presents for the first time the experimental implementation of coherent Raman oscillations with a femtosecond frequency comb for transition frequencies in the THz range. The technique has been successfully demonstrated before to drive Raman transitions between hyperfine structure states...... to destructive interference. Therefore, GDD is compensated using a prism compressor and it is shown quantitatively that the measured GDD matches the theoretically predicted effect on the total Raman Rabi frequency. For the measurements and compensation of GDD, the techniques of interferometric autocorrelation...

  7. Human-Induced Effects on RSS Ranging Measurements for Cooperative Positioning

    Directory of Open Access Journals (Sweden)

    Francescantonio Della Rosa

    2012-01-01

    Full Text Available We present experimental evaluations of human-induced perturbations on received-signal-strength-(RSS- based ranging measurements for cooperative mobile positioning. To the best of our knowledge, this work is the first attempt to gain insight and understand the impact of both body loss and hand grip on the RSS for enhancing proximity measurements among neighbouring devices in cooperative scenarios. Our main contribution is represented by experimental investigations. Analysis of the errors introduced in the distance estimation using path-loss-based methods has been carried out. Moreover, the exploitation of human-induced perturbations for enhancing the final positioning accuracy through cooperative schemes has been assessed. It has been proved that the effect of cooperation is very limited if human factors are not taken into account when performing experimental activities.

  8. L’analisi delle decisioni negli studi di farmacoeconomia

    Directory of Open Access Journals (Sweden)

    Antonella Bacchieri

    2005-06-01

    Full Text Available This paper is a review of the decision tree methodology. This is a very useful technique in complex decision making, when the consequences of the decisions are distant in time and the information upon which we can rely is uncertain. Decision trees are the basic structure underlying most applications of decision analysis in medicine. However, in this review we only cover their application to the pharmaco-economic field. The main steps of this decision analysis are explained. Thereafter, a case study from the literature is used as an example, i.e. an application of the decision tree analysis to a study aimed at comparing two different drugs in the treatment of gastro-esophageal reflux. The main focus of our paper is on the statistical aspects, which include the definition and quantification of the outcome variables, the definition and quantification of the probabilities of occurrence of the uncertain events considered in the decision tree, and the sensitivity analysis. The knowledge of the basic laws of the probability theory is mandatory for assigning correct values to the parameters of the decision tree (outcomes and probabilities. Finally, the sensitivity analysis is an important part of the work to be performed in the last stage of the decision analysis in order to measure the degree of robustness of the results when varying the assumptions.

  9. The validity and reliability of a new instrumented device for measuring ankle dorsiflexion range of motion.

    Science.gov (United States)

    Calatayud, Joaquin; Martin, Fernando; Gargallo, Pedro; García-Redondo, Jessica; Colado, Juan Carlos; Marín, Pedro J

    2015-04-01

    A restriction in ankle dorsiflexion range of motion (ROM) has been linked to several clinical manifestations such as metatarsalgia, heel pain, nerve entrapment, ankle joint equinus, patellar and ankle injuries. The purpose of the present study was to examine the validity and reliability of the Leg Motion system for measuring ankle dorsiflexion ROM. Descriptive repeated-measures study. Twenty-six healthy male university students were recruited to test the reliability of the Leg Motion system, which is a portable tool used for assessment of ankle dorsiflexion during the weight-bearing lunge test. The participants were tested two times separated by two weeks and measurements were performed at the same time of the day by the same single rater. To test the validity of the Leg Motion system, other maximal ankle dorsiflexion ROM assessments (goniometer, inclinometer and measuring tape) were measured in a single session (i.e., the first test session) during the weight-bearing lunge position using a standard goniometer, a digital inclinometer and a measuring tape measure with the ability to measure to the nearest 0.1 cm. Paired t-tests showed the absence of significant differences between right and left limb measurements of dorsiflexion in all tests. Mean values ± standard deviations were as follows: Leg Motion test (left 11.6cm±3.9; right 11.9cm ±4.0), tape measure (left 11.6cm±4.0; right 11.8cm±4.2), goniometer (left 40.6º±5.2; right 40.6º±5.2), and digital inclinometer (left 40.0º±5.8; right 39.9º±5.6). The Leg Motion composite values (i.e., average of the two legs) showed a significant (pMotion system as a valid, portable, and easy to use alternative to the weight-bearing lunge test to assess ankle dorsiflexion ROM in healthy participants. 2b.

  10. The 1995-99 measurements of the Lense-Thirring effect using laser-ranged satellites

    Science.gov (United States)

    Ciufolini, Ignazio

    2000-06-01

    In general relativity a current of mass-energy, such as a spinning body, gives rise to peculiar phenomena on bodies, particles and clocks in its vicinity, which are not predicted by the Newtonian gravitational theory; one of these phenomena is the Lense-Thirring effect on particles orbiting a spinning central body. In this paper we first review the method used to measure the Lense-Thirring effect, by analysing the orbits of the two laser-ranged satellites LAGEOS and LAGEOS II, that has provided a direct measurements of this effect; we then report on these detections of the Lense-Thirring effect, obtained by analysing the nodes of LAGEOS and LAGEOS II and the perigee of LAGEOS II with the orbital programs GEODYN-SOLVE, using the Earth gravitational models JGM-3 and EGM-96 and this new method. The first detection was obtained in 1995, the most accurate measurements were obtained in 1998 using EGM-96, with about 20-30% accuracy. Finally, we briefly review the proposed LARES experiment to measure the Lense-Thirring effect with an accuracy of about 2-3% and to provide other basic tests of general relativity and gravitation.

  11. Development of a Coherent Differential Absorption Lidar for Range Resolved Atmospheric CO2 Measurements

    Science.gov (United States)

    Yu, Jirong; Petros, Mulgueta; Chen, Songsheng; Bai, Yingxin; Petzar, Paul J.; Trieu, Bo. C.; Koch, Grady J.; Beyon, Jeffery J.; Singh, Upendra N.

    2010-01-01

    A pulsed, 2-m coherent Differential Absorption Lidar (DIAL) / Integrated Path Differential Absorption (IPDA) transceiver, developed under the Laser Risk Reduction Program (LRRP) at NASA, is integrated into a fully functional lidar instrument. This instrument will measure atmospheric CO2 profiles (by DIAL) initially from a ground platform, and then be prepared for aircraft installation to measure the atmospheric CO2 column densities in the atmospheric boundary layer (ABL) and lower troposphere. The airborne prototype CO2 lidar can measure atmospheric CO2 column density in a range bin of 1km with better than 1.5% precision at horizontal resolution of less than 50km. It can provide the image of the pooling of CO2 in lowlying areas and performs nighttime mass balance measurements at landscape scale. This sensor is unique in its capability to study the vertical ABL-free troposphere exchange of CO2 directly. It will allow the investigators to pursue subsequent in science-driven deployments, and provides a unique tool for Active Sensing of CO2 Emissions over Night, Days, and Seasons (ASCENDS) validation that was strongly advocated in the recent ASCENDS Workshop.

  12. Measurement of peak impact loads differ between accelerometers - Effects of system operating range and sampling rate.

    Science.gov (United States)

    Ziebart, Christina; Giangregorio, Lora M; Gibbs, Jenna C; Levine, Iris C; Tung, James; Laing, Andrew C

    2017-06-14

    A wide variety of accelerometer systems, with differing sensor characteristics, are used to detect impact loading during physical activities. The study examined the effects of system characteristics on measured peak impact loading during a variety of activities by comparing outputs from three separate accelerometer systems, and by assessing the influence of simulated reductions in operating range and sampling rate. Twelve healthy young adults performed seven tasks (vertical jump, box drop, heel drop, and bilateral single leg and lateral jumps) while simultaneously wearing three tri-axial accelerometers including a criterion standard laboratory-grade unit (Endevco 7267A) and two systems primarily used for activity-monitoring (ActiGraph GT3X+, GCDC X6-2mini). Peak acceleration (gmax) was compared across accelerometers, and errors resulting from down-sampling (from 640 to 100Hz) and range-limiting (to ±6g) the criterion standard output were characterized. The Actigraph activity-monitoring accelerometer underestimated gmax by an average of 30.2%; underestimation by the X6-2mini was not significant. Underestimation error was greater for tasks with greater impact magnitudes. gmax was underestimated when the criterion standard signal was down-sampled (by an average of 11%), range limited (by 11%), and by combined down-sampling and range-limiting (by 18%). These effects explained 89% of the variance in gmax error for the Actigraph system. This study illustrates that both the type and intensity of activity should be considered when selecting an accelerometer for characterizing impact events. In addition, caution may be warranted when comparing impact magnitudes from studies that use different accelerometers, and when comparing accelerometer outputs to osteogenic impact thresholds proposed in literature. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

  13. Escopo de projeto para criação de um Plano de Negócios

    Directory of Open Access Journals (Sweden)

    Armando Terribili Filho

    2014-04-01

    Full Text Available No Brasil, 27% das empresas criadas encerrem suas atividades no primeiro ano de existência, e 58% delas até o final do quinto ano. Assim, os objetivos do artigo são: apresentar a composição de um Plano de Negócios por meio da EAP (Estrutura Analítica de Projetos utilizando o padrão do Guia PMBOK® (Project Management Body of Knowledge, e discutir se a criação de um Plano de Negócios aumentaria a probabilidade de sucesso de uma nova empresa. A metodologia utilizada foi composta de três etapas: revisão bibliográfica, definição dos entregáveis de um projeto para criação de um novo negócio e análise das principais razões para o encerramento de uma empresa em seus primeiros anos de existência. Os resultados apontaram que a existência de um Plano de Negócios não é sinônimo de sucesso, mas, certamente aumenta a probabilidade disto acontecer, pois a maioria das causas identificadas teria sido suprida pela elaboração de um Plano de Negócios.

  14. Plano de negócios: empresa de comércio electrónico

    OpenAIRE

    Simões, Paula Marise Martins Jorge

    2010-01-01

    Mestrado em Gestão O crescimento exponencial da internet potenciou profundas alterações nos comportamentos dos consumidores, dando origem a uma nova forma de comprar, o comércio electrónico. Neste trabalho é elaborado o plano de negócios da empresa G2R que propõe a comercialização de equipamentos para motociclistas exclusivamente através de uma loja online. A proposta da empresa é inovadora em Portugal pela quase inexistência de pure players 1 no mercado nacional e pela l...

  15. Plano de Negócios de uma microempresa de Pescaturismo no litoral caminhense

    OpenAIRE

    AZEVEDO,Carlos

    2016-01-01

    O presente estudo de dissertação consiste no estudo da viabilidade económica e financeira de uma microempresa de Pescaturismo. Trata-se da apresentação de um plano de negócios turístico-pesqueiro, onde a principal ideia - através de um modelo de intraempreendedorismo marítimo de criação de valor social, económico e financeiro - é a conceção de uma unidade empresarial, sob o conceito de turismo marítimo-pesqueiro, estrategicamente posicionada no nicho de mercado de turismo criativo e costeiro,...

  16. Measurements of pulse rate using long-range imaging photoplethysmography and sunlight illumination outdoors

    Science.gov (United States)

    Blackford, Ethan B.; Estepp, Justin R.

    2017-02-01

    Imaging photoplethysmography, a method using imagers to record absorption variations caused by microvascular blood volume pulsations, shows promise as a non-contact cardiovascular sensing technology. The first long-range imaging photoplethysmography measurements at distances of 25, 50, and 100 meters from the participant was recently demonstrated. Degraded signal quality was observed with increasing imager-to-subject distances. The degradation in signal quality was hypothesized to be largely attributable to inadequate light return to the image sensor with increasing lens focal length. To test this hypothesis, a follow-up evaluation with 27 participants was conducted outdoors with natural sunlight illumination resulting in 5-33 times the illumination intensity. Video was recorded from cameras equipped with ultra-telephoto lenses and positioned at distances of 25, 50, 100, and 150 meters. The brighter illumination allowed high-definition video recordings at increased frame rates of 60fps, shorter exposure times, and lower ISO settings, leading to higher quality image formation than the previous indoor evaluation. Results were compared to simultaneous reference measurements from electrocardiography. Compared to the previous indoor study, we observed lower overall error in pulse rate measurement with the same pattern of degradation in signal quality with respect to increasing distance. This effect was corroborated by the signal-to-noise ratio of the blood volume pulse signal which also showed decreasing quality with respect to increasing distance. Finally, a popular chrominance-based method was compared to a blind source separation approach; while comparable in measurement of signal-to-noise ratio, we observed higher overall error in pulse rate measurement using the chrominance method in this data.

  17. At Home Photography-Based Method for Measuring Wrist Range of Motion.

    Science.gov (United States)

    Trehan, Samir K; Rancy, Schneider K; Johnsen, Parker H; Hillstrom, Howard J; Lee, Steve K; Wolfe, Scott W

    2017-11-01

    Purpose  To determine the reliability of wrist range of motion (WROM) measurements based on digital photographs taken by patients at home compared with traditional measurements done in the office with a goniometer. Methods  Sixty-nine postoperative patients were enrolled in this study at least 3 months postoperatively. Active and passive wrist flexion/extension and radial/ulnar deviation were recorded by one of the two attending surgeons with a 1-degree resolution goniometer at the last postoperative office visit. Patients were provided an illustrated instruction sheet detailing how to take digital photographic images at home in six wrist positions (active and passive flexion/extension, and radial/ulnar deviation). Wrist position was measured from digital images by both the attending surgeons in a randomized, blinded fashion on two separate occasions greater than 2 weeks apart using the same goniometer. Reliability analysis was performed using the intraclass correlation coefficient to assess agreement between clinical and photography-based goniometry, as well as intra- and interobserver agreement. Results  Out of 69 enrolled patients, 30 (43%) patients sent digital images. Of the 180 digital photographs, only 9 (5%) were missing or deemed inadequate for WROM measurements. Agreement between clinical and photography-based measurements was "almost perfect" for passive wrist flexion/extension and "substantial" for active wrist flexion/extension and radial/ulnar deviation. Inter- and intraobserver agreement for the attending surgeons was "almost perfect" for all measurements. Discussion  This study validates a photography-based goniometry protocol allowing accurate and reliable WROM measurements without direct physician contact. Passive WROM was more accurately measured from photographs than active WROM. This study builds on previous photography-based goniometry literature by validating a protocol in which patients or their families take and submit their own

  18. Measurement of the extreme ankle range of motion required by female ballet dancers.

    Science.gov (United States)

    Russell, Jeffrey A; Kruse, David W; Nevill, Alan M; Koutedakis, Yiannis; Wyon, Matthew A

    2010-12-01

    Female ballet dancers require extreme ankle motion, especially plantar flexion, but research about measuring such motion is lacking. The purposes of this study were to determine in a sample of ballet dancers whether non-weight-bearing ankle range of motion is significantly different from the weight-bearing equivalent and whether inclinometric plantar flexion measurement is a suitable substitute for standard plantar flexion goniometry. Fifteen female ballet dancers (5 university, 5 vocational, and 5 professional dancers; age 21 ± 3.0 years) volunteered. Subjects received 5 assessments on 1 ankle: non-weight-bearing goniometry dorsiflexion (NDF) and plantar flexion (NPF), weight-bearing goniometry in the ballet positions demi-plié (WDF) and en pointe (WPF), and non-weight-bearing plantar flexion inclinometry (IPF). Mean NDF was significantly lower than WDF (17° ± 1.3° vs 30° ± 1.8°, P ballet proficiency. The authors conclude that assessment of extreme ankle motion in female ballet dancers is challenging, and goniometry and inclinometry appear to measure plantar flexion differently.

  19. Accelerated ice-sheet mass loss in Antarctica from 18-year satellite laser ranging measurements

    Directory of Open Access Journals (Sweden)

    Shuanggen Jin

    2016-02-01

    Full Text Available Accurate estimate of the ice-sheet mass balance in Antarctic is very difficult due to complex ice sheet condition and sparse in situ measurements. In this paper, the low-degree gravity field coefficients of up to degree and order 5 derived from Satellite Laser Ranging (SLR measurements are used to determine the ice mass variations in Antarctica for the period 1993–2011. Results show that the ice mass is losing with -36±13 Gt/y in Antarctica, -42±11 Gt/y in the West Antarctica and 6±10 Gt/y in the East Antarctica from 1993 to 2011. The ice mass variations from the SLR 5×5 have a good agreement with the GRACE 5×5, GRACE 5×5 (1&2 and GRACE (60×60 for the entire continent since 2003, but degree 5 from SLR is not sufficient to quantify ice losses in West and East Antarctica, respectively. The rate of ice loss in Antarctica is -28±17 Gt/y for 1993-2002 and -55±17 Gt/y for 2003-2011, indicating significant accelerated ice mass losses since 2003. Furthermore, the results from SLR are comparable with GRACE measurements.

  20. Accurate Measurements of Aerosol Hygroscopic Growth over a Wide Range in Relative Humidity.

    Science.gov (United States)

    Rovelli, Grazia; Miles, Rachael E H; Reid, Jonathan P; Clegg, Simon L

    2016-06-30

    Using a comparative evaporation kinetics approach, we describe a new and accurate method for determining the equilibrium hygroscopic growth of aerosol droplets. The time-evolving size of an aqueous droplet, as it evaporates to a steady size and composition that is in equilibrium with the gas phase relative humidity, is used to determine the time-dependent mass flux of water, yielding information on the vapor pressure of water above the droplet surface at every instant in time. Accurate characterization of the gas phase relative humidity is provided from a control measurement of the evaporation profile of a droplet of know equilibrium properties, either a pure water droplet or a sodium chloride droplet. In combination, and by comparison with simulations that account for both the heat and mass transport governing the droplet evaporation kinetics, these measurements allow accurate retrieval of the equilibrium properties of the solution droplet (i.e., the variations with water activity in the mass fraction of solute, diameter growth factor, osmotic coefficient or number of water molecules per solute molecule). Hygroscopicity measurements can be made over a wide range in water activity (from >0.99 to, in principle, 0.9 and ∼±1% below 80% RH, and maximum uncertainties in diameter growth factor of ±0.7%. For all of the inorganic systems examined, the time-dependent data are consistent with large values of the mass accommodation (or evaporation) coefficient (>0.1).

  1. Realization of High Dynamic Range Imaging in the GLORIA Network and Its Effect on Astronomical Measurement

    Directory of Open Access Journals (Sweden)

    Stanislav Vítek

    2016-01-01

    Full Text Available Citizen science project GLORIA (GLObal Robotic-telescopes Intelligent Array is a first free- and open-access network of robotic telescopes in the world. It provides a web-based environment where users can do research in astronomy by observing with robotic telescopes and/or by analyzing data that other users have acquired with GLORIA or from other free-access databases. Network of 17 telescopes allows users to control selected telescopes in real time or schedule any more demanding observation. This paper deals with new opportunity that GLORIA project provides to teachers and students of various levels of education. At the moment, there are prepared educational materials related to events like Sun eclipse (measuring local atmosphere changes, Aurora Borealis (calculation of Northern Lights height, or transit of Venus (measurement of the Earth-Sun distance. Student should be able to learn principles of CCD imaging, spectral analysis, basic calibration like dark frames subtraction, or advanced methods of noise suppression. Every user of the network can design his own experiment. We propose advanced experiment aimed at obtaining astronomical image data with high dynamic range. We also introduce methods of objective image quality evaluation in order to discover how HDR methods are affecting astronomical measurements.

  2. Respiration rate of stream insects measured in situ along a large altitude range

    DEFF Research Database (Denmark)

    Rostgaard, S.; Jacobsen, D.

    2005-01-01

    conditions in streams from 400 to 3800 m above sea level in tropical Ecuador. Mean active respiration rates of the animals at 3800 m were approximately half of those at 400 m. Trichoptera showed a slightly larger difference in respiration with altitude than Ephemeroptera. Comparative respiration measurements...... at 100 and 50% oxygen saturation indicated that highland animals reduced their oxygen uptake more than their counterparts in the lowland when oxygen availability decreased. The temperature response of respiration calculated between the insect assemblages at different altitudes showed a mean assemblage Q...... to temperature in tropical streams is probably due to full acclimatization of the component species to stable and narrow temperature ranges. Adaptations to the low oxygen availability at high altitude probably consist of a suite of genetic physiological and behavioural features....

  3. OPO DIAL lidar for remote measurements of atmospheric gases in the IR range

    Science.gov (United States)

    Romanovskii, O. A.; Kharchenko, O. V.; Shumskii, V. K.; Sadovnikov, S. A.; Yakovlev, S. V.

    2016-05-01

    Applicability of a KTA crystal-based laser system with optical parametric oscillators (OPO) generation to lidar sounding of the atmosphere in the spectral range 3-4 μm is studied in this work. A technique developed for lidar sounding of trace atmospheric gases (TAG) is based on differential absorption lidar (DIAL) method and differential optical absorption spectroscopy (DOAS). The new technique uses broadband radiation and a CCD detector, which ensures measurement of backscattering signals with simultaneous altitude and wavelength resolution. The DIAL-DOAS technique is tested to estimate its efficiency for lidar sounding of atmospheric trace gases. The numerical simulation performed shows that a KTA-based OPO laser is a promising source of radiation for remote DIAL-DOAS sounding of the TAGs under study along surface tropospheric paths. The laser system design provides a possibility of narrowing the laser line within the 0.01-5 cm-1 limits. This possible improvement along with a small step of laser line tuning and the presence of absorption lines of other atmospheric gases, including atmospheric pollutants, in the spectral range under study make this laser a unique instrument for atmospheric sounding.

  4. Design Optimization for the Measurement Accuracy Improvement of a Large Range Nanopositioning Stage

    Directory of Open Access Journals (Sweden)

    Marta Torralba

    2016-01-01

    Full Text Available Both an accurate machine design and an adequate metrology loop definition are critical factors when precision positioning represents a key issue for the final system performance. This article discusses the error budget methodology as an advantageous technique to improve the measurement accuracy of a 2D-long range stage during its design phase. The nanopositioning platform NanoPla is here presented. Its specifications, e.g., XY-travel range of 50 mm × 50 mm and sub-micrometric accuracy; and some novel designed solutions, e.g., a three-layer and two-stage architecture are described. Once defined the prototype, an error analysis is performed to propose improvement design features. Then, the metrology loop of the system is mathematically modelled to define the propagation of the different sources. Several simplifications and design hypothesis are justified and validated, including the assumption of rigid body behavior, which is demonstrated after a finite element analysis verification. The different error sources and their estimated contributions are enumerated in order to conclude with the final error values obtained from the error budget. The measurement deviations obtained demonstrate the important influence of the working environmental conditions, the flatness error of the plane mirror reflectors and the accurate manufacture and assembly of the components forming the metrological loop. Thus, a temperature control of ±0.1 °C results in an acceptable maximum positioning error for the developed NanoPla stage, i.e., 41 nm, 36 nm and 48 nm in X-, Y- and Z-axis, respectively.

  5. Higher measured than modeled ozone production at increased NOx levels in the Colorado Front Range

    Science.gov (United States)

    Baier, Bianca C.; Brune, William H.; Miller, David O.; Blake, Donald; Long, Russell; Wisthaler, Armin; Cantrell, Christopher; Fried, Alan; Heikes, Brian; Brown, Steven; McDuffie, Erin; Flocke, Frank; Apel, Eric; Kaser, Lisa; Weinheimer, Andrew

    2017-09-01

    Chemical models must correctly calculate the ozone formation rate, P(O3), to accurately predict ozone levels and to test mitigation strategies. However, air quality models can have large uncertainties in P(O3) calculations, which can create uncertainties in ozone forecasts, especially during the summertime when P(O3) is high. One way to test mechanisms is to compare modeled P(O3) to direct measurements. During summer 2014, the Measurement of Ozone Production Sensor (MOPS) directly measured net P(O3) in Golden, CO, approximately 25 km west of Denver along the Colorado Front Range. Net P(O3) was compared to rates calculated by a photochemical box model that was constrained by measurements of other chemical species and that used a lumped chemical mechanism and a more explicit one. Median observed P(O3) was up to a factor of 2 higher than that modeled during early morning hours when nitric oxide (NO) levels were high and was similar to modeled P(O3) for the rest of the day. While all interferences and offsets in this new method are not fully understood, simulations of these possible uncertainties cannot explain the observed P(O3) behavior. Modeled and measured P(O3) and peroxy radical (HO2 and RO2) discrepancies observed here are similar to those presented in prior studies. While a missing atmospheric organic peroxy radical source from volatile organic compounds co-emitted with NO could be one plausible solution to the P(O3) discrepancy, such a source has not been identified and does not fully explain the peroxy radical model-data mismatch. If the MOPS accurately depicts atmospheric P(O3), then these results would imply that P(O3) in Golden, CO, would be NOx-sensitive for more of the day than what is calculated by models, extending the NOx-sensitive P(O3) regime from the afternoon further into the morning. These results could affect ozone reduction strategies for the region surrounding Golden and possibly other areas that do not comply with national ozone regulations

  6. Higher measured than modeled ozone production at increased NOx levels in the Colorado Front Range

    Directory of Open Access Journals (Sweden)

    B. C. Baier

    2017-09-01

    Full Text Available Chemical models must correctly calculate the ozone formation rate, P(O3, to accurately predict ozone levels and to test mitigation strategies. However, air quality models can have large uncertainties in P(O3 calculations, which can create uncertainties in ozone forecasts, especially during the summertime when P(O3 is high. One way to test mechanisms is to compare modeled P(O3 to direct measurements. During summer 2014, the Measurement of Ozone Production Sensor (MOPS directly measured net P(O3 in Golden, CO, approximately 25 km west of Denver along the Colorado Front Range. Net P(O3 was compared to rates calculated by a photochemical box model that was constrained by measurements of other chemical species and that used a lumped chemical mechanism and a more explicit one. Median observed P(O3 was up to a factor of 2 higher than that modeled during early morning hours when nitric oxide (NO levels were high and was similar to modeled P(O3 for the rest of the day. While all interferences and offsets in this new method are not fully understood, simulations of these possible uncertainties cannot explain the observed P(O3 behavior. Modeled and measured P(O3 and peroxy radical (HO2 and RO2 discrepancies observed here are similar to those presented in prior studies. While a missing atmospheric organic peroxy radical source from volatile organic compounds co-emitted with NO could be one plausible solution to the P(O3 discrepancy, such a source has not been identified and does not fully explain the peroxy radical model–data mismatch. If the MOPS accurately depicts atmospheric P(O3, then these results would imply that P(O3 in Golden, CO, would be NOx-sensitive for more of the day than what is calculated by models, extending the NOx-sensitive P(O3 regime from the afternoon further into the morning. These results could affect ozone reduction strategies for the region surrounding Golden and possibly other areas that do not comply with national ozone

  7. Maturidade do Negócio e Comércio Electrónico nas Microempresas Portuguesas

    OpenAIRE

    Barros, Luís Gonzaga Valente de

    2009-01-01

    Dissertação de Mestrado em em Tecnologias de Informação e Comunicação O negócio electrónico está associado à utilização intensiva de tecnologias de informação e comunicação. No entanto, para implementar iniciativas de negócio electrónico, é necessário bem mais do que utilizar computadores e redes. Aspectos como o mercado, o nível de integração funcional das organizações e de preparação de sistemas e a oferta de produtos e serviços têm de estar devidamente acautelados. O termo negócio ele...

  8. Objective Measurement of Fusional Vergence Ranges and Heterophoria in Infants and Preschool Children

    Science.gov (United States)

    Sreenivasan, Vidhyapriya; Babinsky, Erin E.; Wu, Yifei; Candy, T. Rowan

    2016-01-01

    Purpose Binocular alignment typically includes motor fusion compensating for heterophoria. This study evaluated heterophoria and then accommodation and vergence responses during measurement of fusional ranges in infants and preschoolers. Methods Purkinje image eye tracking and eccentric photorefraction (MCS PowerRefractor) were used to record the eye alignment and accommodation of uncorrected infants (n = 17; 3–5 months old), preschoolers (n = 19; 2.5–5 years), and naïve functionally emmetropic adults (n = 14; 20–32 years; spherical equivalent [SE], +1 to −1 diopters [D]). Heterophoria was derived from the difference between monocular and binocular alignments while participants viewed naturalistic images at 80 cm. The presence or absence of fusion was then assessed after base-in (BI) and base-out (BO) prisms (2–40 prism diopters [pd]) were introduced. Results Mean (±SD) SE refractions were hyperopic in infants (+2.4 ± 1.2 D) and preschoolers (+1.1 ± 0.6 D). The average exophoria was similar (P = 0.11) across groups (Infants, −0.79 ± 2.5 pd; Preschool, −2.43 ± 2.0 pd; Adults, −1.0 ± 2.7 pd). Mean fusional vergence range also was similar (P = 0.1) for BI (Infants, 11.2 ± 2.5 pd; Preschool, 8.8 ± 2.8 pd; Adults, 11.8 ± 5.2 pd) and BO (Infants, 14 ± 6.6 pd; Preschool, 15.3 ± 8.3 pd; Adults, 20 ± 9.2 pd). Maximum change in accommodation to the highest fusible prism was positive (increased accommodation) for BO (Infants, 1.69 ± 1.4 D; Preschool, 1.35 ± 1.6 D; Adults, 1.22 ± 1.0 D) and negative for BI (Infants, −0.96 ± 1.0 D; Preschool, −0.78 ± 0.6 D; Adults, −0.62 ± 0.3 D), with a similar magnitude across groups (BO, P = 0.6; BI, P = 0.4). Conclusions Despite typical uncorrected hyperopia, infants and preschoolers exhibited small exophorias at 80 cm, similar to adults. All participants demonstrated substantial fusional ranges, providing evidence that even 3- to 5-month-old infants can respond to a large range of image disparities

  9. Outlier Detection in GNSS Pseudo-Range/Doppler Measurements for Robust Localization.

    Science.gov (United States)

    Zair, Salim; Le Hégarat-Mascle, Sylvie; Seignez, Emmanuel

    2016-04-22

    In urban areas or space-constrained environments with obstacles, vehicle localization using Global Navigation Satellite System (GNSS) data is hindered by Non-Line Of Sight (NLOS) and multipath receptions. These phenomena induce faulty data that disrupt the precise localization of the GNSS receiver. In this study, we detect the outliers among the observations, Pseudo-Range (PR) and/or Doppler measurements, and we evaluate how discarding them improves the localization. We specify a contrario modeling for GNSS raw data to derive an algorithm that partitions the dataset between inliers and outliers. Then, only the inlier data are considered in the localization process performed either through a classical Particle Filter (PF) or a Rao-Blackwellization (RB) approach. Both localization algorithms exclusively use GNSS data, but they differ by the way Doppler measurements are processed. An experiment has been performed with a GPS receiver aboard a vehicle. Results show that the proposed algorithms are able to detect the 'outliers' in the raw data while being robust to non-Gaussian noise and to intermittent satellite blockage. We compare the performance results achieved either estimating only PR outliers or estimating both PR and Doppler outliers. The best localization is achieved using the RB approach coupled with PR-Doppler outlier estimation.

  10. Reliability assessment of measuring active wrist pronation and supination range of motion with a smartphone.

    Science.gov (United States)

    Santos, C; Pauchard, N; Guilloteau, A

    2017-10-01

    This study aimed to improve clinical examination techniques by determining the reliability of different methods to evaluate forearm movements. Two methods using the iPhone™ 5 and its gyroscope application (alone [I5] or attached to a selfie stick [ISS]) were compared with two conventional measurement devices (a plastic goniometer with a hand-held pencil [HHP] and a bubble goniometer [BG]) to evaluate the active range of movement (AROM) of the wrist during pronation and supination. Two independent groups of subjects took part in this prospective single-center diagnostic study: 20 healthy subjects and 20 patients. The four evaluation methods had high intra-observer consistency after three measurements (intra-class correlation coefficient [ICC] [3, 1] of 0.916 for the HHP; 0.944 for ISS; 0.925 for BG; 0.933 for I5) and excellent inter-observer reliability (ICC [2, k] of 0.926 for HHP; 0.934 for ISS; 0.899 for BG; 0.894 for I5), with an agreement of plus or minus 2°. When these devices are used with rigorous methodology, they are reliable for the goniometric evaluation of AROM of wrist pronation and supination. Copyright © 2017 SFCM. Published by Elsevier Masson SAS. All rights reserved.

  11. Outlier Detection in GNSS Pseudo-Range/Doppler Measurements for Robust Localization

    Directory of Open Access Journals (Sweden)

    Salim Zair

    2016-04-01

    Full Text Available In urban areas or space-constrained environments with obstacles, vehicle localization using Global Navigation Satellite System (GNSS data is hindered by Non-Line Of Sight (NLOS and multipath receptions. These phenomena induce faulty data that disrupt the precise localization of the GNSS receiver. In this study, we detect the outliers among the observations, Pseudo-Range (PR and/or Doppler measurements, and we evaluate how discarding them improves the localization. We specify a contrario modeling for GNSS raw data to derive an algorithm that partitions the dataset between inliers and outliers. Then, only the inlier data are considered in the localization process performed either through a classical Particle Filter (PF or a Rao-Blackwellization (RB approach. Both localization algorithms exclusively use GNSS data, but they differ by the way Doppler measurements are processed. An experiment has been performed with a GPS receiver aboard a vehicle. Results show that the proposed algorithms are able to detect the ‘outliers’ in the raw data while being robust to non-Gaussian noise and to intermittent satellite blockage. We compare the performance results achieved either estimating only PR outliers or estimating both PR and Doppler outliers. The best localization is achieved using the RB approach coupled with PR-Doppler outlier estimation.

  12. Prototype system for proton beam range measurement based on gamma electron vertex imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Han Rim [Neutron Utilization Technology Division, Korea Atomic Energy Research Institute, 111, Daedeok-daero 989beon-gil, Yuseong-gu, Daejeon 34057 (Korea, Republic of); Kim, Sung Hun; Park, Jong Hoon [Department of Nuclear Engineering, Hanyang University, Seongdong-gu, Seoul 04763 (Korea, Republic of); Jung, Won Gyun [Heavy-ion Clinical Research Division, Korean Institute of Radiological & Medical Sciences, Seoul 01812 (Korea, Republic of); Lim, Hansang [Department of Electronics Convergence Engineering, Kwangwoon University, Seoul 01897 (Korea, Republic of); Kim, Chan Hyeong, E-mail: chkim@hanyang.ac.kr [Department of Nuclear Engineering, Hanyang University, Seongdong-gu, Seoul 04763 (Korea, Republic of)

    2017-06-11

    In proton therapy, for both therapeutic effectiveness and patient safety, it is very important to accurately measure the proton dose distribution, especially the range of the proton beam. For this purpose, recently we proposed a new imaging method named gamma electron vertex imaging (GEVI), in which the prompt gammas emitting from the nuclear reactions of the proton beam in the patient are converted to electrons, and then the converted electrons are tracked to determine the vertices of the prompt gammas, thereby producing a 2D image of the vertices. In the present study, we developed a prototype GEVI system, including dedicated signal processing and data acquisition systems, which consists of a beryllium plate (= electron converter) to convert the prompt gammas to electrons, two double-sided silicon strip detectors (= hodoscopes) to determine the trajectories of those converted electrons, and a plastic scintillation detector (= calorimeter) to measure their kinetic energies. The system uses triple coincidence logic and multiple energy windows to select only the events from prompt gammas. The detectors of the prototype GEVI system were evaluated for electronic noise level, energy resolution, and time resolution. Finally, the imaging capability of the GEVI system was tested by imaging a {sup 90}Sr beta source, a {sup 60}Co gamma source, and a 45-MeV proton beam in a PMMA phantom. The overall results of the present study generally show that the prototype GEVI system can image the vertices of the prompt gammas produced by the proton nuclear interactions.

  13. Validity and reliability of using photography for measuring knee range of motion: a methodological study.

    Science.gov (United States)

    Naylor, Justine M; Ko, Victoria; Adie, Sam; Gaskin, Clive; Walker, Richard; Harris, Ian A; Mittal, Rajat

    2011-04-18

    The clinimetric properties of knee goniometry are essential to appreciate in light of its extensive use in the orthopaedic and rehabilitative communities. Intra-observer reliability is thought to be satisfactory, but the validity and inter-rater reliability of knee goniometry often demonstrate unacceptable levels of variation. This study tests the validity and reliability of measuring knee range of motion using goniometry and photographic records. Methodology study assessing the validity and reliability of one method ('Marker Method') which uses a skin marker over the greater trochanter and another method ('Line of Femur Method') which requires estimation of the line of femur. Radiology and orthopaedic departments of two teaching hospitals. 31 volunteers (13 arthritic and 18 healthy subjects). Knee range of motion was measured radiographically and photographically using a goniometer. Three assessors were assessed for reliability and validity. Agreement between methods and within raters was assessed using concordance correlation coefficient (CCCs). Agreement between raters was assessed using intra-class correlation coefficients (ICCs). 95% limits of agreement for the mean difference for all paired comparisons were computed. Validity (referenced to radiographs): Each method for all 3 raters yielded very high CCCs for flexion (0.975 to 0.988), and moderate to substantial CCCs for extension angles (0.478 to 0.678). The mean differences and 95% limits of agreement were narrower for flexion than they were for extension. Intra-rater reliability: For flexion and extension, very high CCCs were attained for all 3 raters for both methods with slightly greater CCCs seen for flexion (CCCs varied from 0.981 to 0.998). Inter-rater reliability: For both methods, very high ICCs (min to max: 0.891 to 0.995) were obtained for flexion and extension. Slightly higher coefficients were obtained for flexion compared to extension, and with the Marker compared to the Line of Femur Method

  14. A Internet das Coisas e o Big Data inovando os negócios

    Directory of Open Access Journals (Sweden)

    Dalma de Oliveira Santos

    2016-10-01

    Full Text Available A Internet das Coisas e o Big Data permitem que grandes volumes de dados sejam analisados, verificados e transformados em informações organizadas para as empresas. Essas informações são utilizadas para que as empresas possam tomar as melhores decisões, apoiando o surgimento de novas perspectivas e, assim, possibilitando que novos impactos transformem a maneira de criar e expandir os negócios. O uso dessas ferramentas cresceu nos últimos anos e existem previsões de crescimento ainda maiores para os próximos anos, inovando o tratamento de dados no cotidiano das empresas fazendo com que os negócios sofram impactos em seus paradigmas. Empresas e usuários precisam se preocupar com as consequências dessa nova maneira de tratamento de dados. O objetivo desse artigo é tratar os aspectos que modificam a forma de trabalho, o uso em empresas e de usuários com o advento da conectividade entre objetos: máquinas com máquinas e pessoas com objetos e máquinas. Além de se propor a analisar as vantagens, as desvantagens e os riscos do uso dessas tecnologias.

  15. Cloud cover detection combining high dynamic range sky images and ceilometer measurements

    Science.gov (United States)

    Román, R.; Cazorla, A.; Toledano, C.; Olmo, F. J.; Cachorro, V. E.; de Frutos, A.; Alados-Arboledas, L.

    2017-11-01

    This paper presents a new algorithm for cloud detection based on high dynamic range images from a sky camera and ceilometer measurements. The algorithm is also able to detect the obstruction of the sun. This algorithm, called CPC (Camera Plus Ceilometer), is based on the assumption that under cloud-free conditions the sky field must show symmetry. The symmetry criteria are applied depending on ceilometer measurements of the cloud base height. CPC algorithm is applied in two Spanish locations (Granada and Valladolid). The performance of CPC retrieving the sun conditions (obstructed or unobstructed) is analyzed in detail using as reference pyranometer measurements at Granada. CPC retrievals are in agreement with those derived from the reference pyranometer in 85% of the cases (it seems that this agreement does not depend on aerosol size or optical depth). The agreement percentage goes down to only 48% when another algorithm, based on Red-Blue Ratio (RBR), is applied to the sky camera images. The retrieved cloud cover at Granada and Valladolid is compared with that registered by trained meteorological observers. CPC cloud cover is in agreement with the reference showing a slight overestimation and a mean absolute error around 1 okta. A major advantage of the CPC algorithm with respect to the RBR method is that the determined cloud cover is independent of aerosol properties. The RBR algorithm overestimates cloud cover for coarse aerosols and high loads. Cloud cover obtained only from ceilometer shows similar results than CPC algorithm; but the horizontal distribution cannot be obtained. In addition, it has been observed that under quick and strong changes on cloud cover ceilometers retrieve a cloud cover fitting worse with the real cloud cover.

  16. Ética nos negócios e ética pessoal: uma questão de integridade

    OpenAIRE

    Ventura, Adriana Miguel

    2010-01-01

    Este trabalho aborda os conceitos de Ética nos Negócios e Ética Pessoal, usando como base a Ética das Virtudes de Robert Solomon, oriunda da abordagem Aristotélica. Discorre sobre conceitos como Valores, Atitudes e Comportamentos, bem como Dissonância Cognitiva e Tomada de Decisão. A coerência da Ética nos Negócios e da Ética Pessoal leva à integridade, a maior das virtudes. Com base no referencial teórico, foi realizada uma pesquisa que tinha por objetivo verificar a coerência entre os compo...

  17. Comparison of linear gain and wide dynamic range compression hearing aid circuits: aided speech perception measures.

    Science.gov (United States)

    Jenstad, L M; Seewald, R C; Cornelisse, L E; Shantz, J

    1999-04-01

    The goal of this study was to test the theoretical advantages of a single-channel wide dynamic range compression (WDRC) circuit for speech intelligibility and loudness comfort for five speech spectra. Twelve adolescents and young adults with moderate to severe hearing loss were fitted with the Siemens Viva 2 Pro behind-the-ear instrument set to DSL 4.0 targets for both linear gain and WDRC processing. Speech intelligibility was measured in the unaided, linear gain and WDRC conditions using two tasks in quiet: nonsense words and sentences. The items were digitally filtered to represent five speech spectra: average speech at 4 m, average speech at 1 m, own voice at ear level, classroom at 1 m, and shouted speech at 1 m. The subjects also rated the loudness of each hearing aid/speech spectrum combination using a categorical rating scale. Both the linear gain and WDRC settings provided improved speech recognition relative to the unaided condition, and the two circuits resulted in equivalent performance for average speech input levels. On average, the WDRC aid resulted in high and uniform speech recognition scores across the five spectra. In contrast, the linear gain aid resulted in a lower recognition score for soft speech and shouted speech relative to that obtained with an average speech level. Analysis of individual speech recognition benefit scores revealed that 11 out of 12 subjects had equal or greater performance with the WDRC processing than the linear processing. Subjective loudness ratings in the linear gain condition were compatible with decreased sensation level for soft speech and loudness discomfort for shouted speech. WDRC processing has potential applications in hearing aid fittings for listeners with moderate to severe hearing loss because it provides a consistently audible and comfortable signal across a wide range of listening conditions in quiet without the need for volume control adjustments.

  18. 40 CFR Table C-1 to Subpart C of... - Test Concentration Ranges, Number of Measurements Required, and Maximum Discrepancy Specification

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 5 2010-07-01 2010-07-01 false Test Concentration Ranges, Number of... Reference Methods Pt. 53, Subpt. C, Table C-1 Table C-1 to Subpart C of Part 53—Test Concentration Ranges, Number of Measurements Required, and Maximum Discrepancy Specification Pollutant Concentration range...

  19. Comércio eletrônico, modelos de negócios e a dinâmica organizacional : caso Cisco

    OpenAIRE

    Rufino, Mônica Soares

    2010-01-01

    Trata dos modelos de negócio que as empresas adotam para implantar o comércio eletrônico e obter vantagens competitivas. Aborda as características dos modelos de negócio, assim como, as estratégias e a dinâmica organizacional inerentes ao processo.

  20. CD28neg. T lymphocytes of a melanoma patient harbor tumor immunity and a high frequency of germline-encoded and public TCRs.

    Science.gov (United States)

    Hashimoto, Hisayoshi; Sterk, Marco; Schilbach, Karin

    2017-11-14

    Increased numbers of CD8+CD28neg. T cells have been detected in the peripheral blood of patients with several types of malignancies. However, the role of these cells in anticancer immunity are not yet clear and CD8+CD28neg. T cells are a controversially discussed subpopulation reported both as immunosuppressive and cytotoxic. In this study, we examined the T cell receptor (TCR) repertoire and complementarity-determining region 3 sequences of CD28neg. T cells in a melanoma patient with recurrent disease who achieved long-term disease-free status. As a result, the patient's oligoclonal CD8+CD28neg. T cell compartment holds TCRs that are public and specific for Melan-A as well as several public TCRs reported for common viral antigens. While over 80% of his CD8+CD28neg. T cells expressed a cytotoxicity marker, CD57, only 0.01% of CD8+ CD28neg. T cells were positive for Foxp3. In conclusion, our results demonstrate that besides virus-specific also tumor-associated self-antigen targeting T cells accumulate in the CD28neg. compartment of the immunological memory. Since the patient is in ongoing complete remission for more than 9 years, CD8+CD28neg. T cells with the Melan-A-specific TCR might contribute to antitumor immunity in this patient.

  1. MeV-range velocity-space tomography from gamma-ray and neutron emission spectrometry measurements at JET

    DEFF Research Database (Denmark)

    Salewski, Mirko; Nocente, M.; Jacobsen, Asger Schou

    2017-01-01

    We demonstrate the measurement of a 2D MeV-range ion velocity distribution function by velocity-space tomography at JET. Deuterium ions were accelerated into the MeV-range by third harmonic ion cyclotron resonance heating. We made measurements with three neutron emission spectrometers and a high-...

  2. Mobile Robot Self-Localization by Matching Range Maps Using a Hausdorff Measure

    Science.gov (United States)

    Olson, C. F.

    1997-01-01

    This paper examines techniques for a mobile robot to perform self-localization in natural terrain by comparing a dense range map computed from stereo imagery to a range map in a known frame of reference.

  3. An intercomparison of POLARIS measurement results from the DTU-ESA Facility and from the ESTEC Near-Field Range

    DEFF Research Database (Denmark)

    Pivnenko, Sergey; Breinbjerg, Olav

    This report documents an intercomparison of measurement results of the POLARIS antenna from measurement at the DTU-ESA Spherical Near-Field Antenna Test Facility in August 2011 and from measurement at the ESTEC Near-Field Range in the fall 2012. The comparison was carried out at the DTU-ESA Facil......This report documents an intercomparison of measurement results of the POLARIS antenna from measurement at the DTU-ESA Spherical Near-Field Antenna Test Facility in August 2011 and from measurement at the ESTEC Near-Field Range in the fall 2012. The comparison was carried out at the DTU...

  4. Measurement of a wide-range of X-ray doses using specialty doped silica fibres

    Science.gov (United States)

    Abdul Sani, S. F.; Hammond, R.; Jafari, S. M.; Wahab, Norfadira; Amouzad Mahdiraji, G.; Siti Shafiqah, A. S.; Abdul Rashid, H. A.; Maah, M. J.; Aldousari, H.; Alkhorayef, M.; Alzimami, M.; Bradley, D. A.

    2017-08-01

    Using six types of tailor-made doped optical fibres, we carry out thermoluminescent (TL) studies of X-rays, investigating the TL yield for doses from 20 mGy through to 50 Gy. Dosimetric parameters were investigated for nominal 8 wt% Ge doped fibres that in two cases were co-doped, using B in one case and Br in the other. A comparative measurement of surface analysis has also been made for non-annealed and annealed capillary fibres, use being made of X-ray Photoelectron Spectroscopy (XPS) analysis. Comparison was made with the conventional TL phosphor LiF in the form of the proprietary product TLD-100, including dose response and glow curves investigated for X-rays generated at 60 kVp over a dose range from 2 cGy to 50 Gy. The energy response of the fibres was also performed for X-rays generated at peak accelerating potentials of 80 kVp, 140 kVp, 250 kVp and 6 MV photons for an absorbed dose of 2 Gy. Present results show the samples to be suitable for use as TL dosimeters, with good linearity of response and a simple glow curve (simple trap) distribution. It has been established that the TL performance of an irradiated fibre is not only influenced by radiation parameters such as energy, dose-rate and total dose but also the type of fibre.

  5. Airborne Dust Cloud Measurements at the INL National Security Test Range

    Energy Technology Data Exchange (ETDEWEB)

    Michael L. Abbott; Norm Stanley; Larry Radke; Charles Smeltzer

    2007-09-01

    On July 11, 2007, a surface, high-explosive test (<20,000 lb TNT-equivalent) was carried out at the National Security Test Range (NSTR) on the Idaho National Laboratory (INL) Site. Aircraft-mounted rapid response (1-sec) particulate monitors were used to measure airborne PM-10 concentrations directly in the dust cloud and to develop a PM-10 emission factor that could be used for subsequent tests at the NSTR. The blast produced a mushroom-like dust cloud that rose approximately 2,500–3,000 ft above ground level, which quickly dissipated (within 5 miles of the source). In general, the cloud was smaller and less persistence than expected, or that might occur in other areas, likely due to the coarse sand and subsurface conditions that characterize the immediate NSTR area. Maximum short time-averaged (1-sec) PM-10 concentrations at the center of the cloud immediately after the event reached 421 µg m-3 but were rapidly reduced (by atmospheric dispersion and fallout) to near background levels (~10 µg m-3) after about 15 minutes. This occurred well within the INL Site boundary, about 8 km (5 miles) from the NSTR source. These findings demonstrate that maximum concentrations in ambient air beyond the INL Site boundary (closest is 11.2 km from NSTR) from these types of tests would be well within the 150 µg m-3 24-hour National Ambient Air Quality Standards for PM-10. Aircraft measurements and geostatistical techniques were used to successfully quantify the initial volume (1.64E+9 m3 or 1.64 km3) and mass (250 kg) of the PM-10 dust cloud, and a PM-10 emission factor (20 kg m-3 crater soil volume) was developed for this specific type of event at NSTR. The 250 kg of PM-10 mass estimated from this experiment is almost seven-times higher than the 36 kg estimated for the environmental assessment (DOE-ID 2007) using available Environmental Protection Agency (EPA 1995) emission factors. This experiment demonstrated that advanced aircraft-mounted instruments operated by

  6. Validity and reliability of using photography for measuring knee range of motion: a methodological study

    Directory of Open Access Journals (Sweden)

    Adie Sam

    2011-04-01

    Full Text Available Abstract Background The clinimetric properties of knee goniometry are essential to appreciate in light of its extensive use in the orthopaedic and rehabilitative communities. Intra-observer reliability is thought to be satisfactory, but the validity and inter-rater reliability of knee goniometry often demonstrate unacceptable levels of variation. This study tests the validity and reliability of measuring knee range of motion using goniometry and photographic records. Methods Design: Methodology study assessing the validity and reliability of one method ('Marker Method' which uses a skin marker over the greater trochanter and another method ('Line of Femur Method' which requires estimation of the line of femur. Setting: Radiology and orthopaedic departments of two teaching hospitals. Participants: 31 volunteers (13 arthritic and 18 healthy subjects. Knee range of motion was measured radiographically and photographically using a goniometer. Three assessors were assessed for reliability and validity. Main outcomes: Agreement between methods and within raters was assessed using concordance correlation coefficient (CCCs. Agreement between raters was assessed using intra-class correlation coefficients (ICCs. 95% limits of agreement for the mean difference for all paired comparisons were computed. Results Validity (referenced to radiographs: Each method for all 3 raters yielded very high CCCs for flexion (0.975 to 0.988, and moderate to substantial CCCs for extension angles (0.478 to 0.678. The mean differences and 95% limits of agreement were narrower for flexion than they were for extension. Intra-rater reliability: For flexion and extension, very high CCCs were attained for all 3 raters for both methods with slightly greater CCCs seen for flexion (CCCs varied from 0.981 to 0.998. Inter-rater reliability: For both methods, very high ICCs (min to max: 0.891 to 0.995 were obtained for flexion and extension. Slightly higher coefficients were obtained

  7. Bovine WC1+ and WC1neg γδ T Lymphocytes Influence Monocyte Differentiation and Monocyte-Derived Dendritic Cell Maturation during In Vitro Mycobacterium avium Subspecies paratuberculosis Infection

    Directory of Open Access Journals (Sweden)

    Monica M. Baquero

    2017-05-01

    Full Text Available During early Mycobacterium avium subspecies paratuberculosis (Map infection, complex interactions occur between the bacteria, cells from the mononuclear phagocyte system (MPS including both resident (macrophages and dendritic cells and recruited (monocytes cells, and other mucosal sentinel cells such as γδ T lymphocytes. Though the details of early host–pathogen interactions in cattle remain largely underexplored, our hypothesis is that these significantly influence development of host immunity and ultimate success or failure of the host to respond to Map infection. The aims of the present study were to first characterize monocyte-derived MPS cells from young calves with respect to their immunophenotype and function. Then, we set out to investigate the effects of WC1+ and WC1neg γδ T lymphocytes on (1 the differentiation of autologous monocytes and (2 the maturation of autologous monocyte-derived dendritic cells (MDDCs. To achieve this, peripheral blood WC1+ or WC1neg γδ T lymphocytes were cocultured with either autologous freshly isolated peripheral blood-derived monocytes or autologous immature MDDCs (iMDDCs. We began by measuring several markers of interest on MPS cells. Useful markers to distinguish monocyte-derived macrophages (MDMs from MDDCs include CD11b, CD163, and CD172a, which are expressed significantly higher on MDMs compared with MDDCs. Function, but not phenotype, was influenced by WC1neg γδ T lymphocytes: viability of Map harvested from monocytes differentiated in the presence of WC1neg γδ T lymphocytes (dMonWC1neg was significantly lower compared to MDMs and MDDCs. With respect to DC maturation, we first showed that mature MDDCs (mMDDCs have significantly higher expression of CD11c, CD80, and CD86 compared with iMDDCs, and the phagocytic capacity of mMDDCs is significantly reduced compared to iMDDCs. We then showed that γδ T lymphocyte subsets induce functional (reduced phagocytosis but not phenotypic (surface

  8. Photon Pressure Force on Space Debris TOPEX/Poseidon Measured by Satellite Laser Ranging

    Science.gov (United States)

    Kucharski, D.; Kirchner, G.; Bennett, J. C.; Lachut, M.; Sośnica, K.; Koshkin, N.; Shakun, L.; Koidl, F.; Steindorfer, M.; Wang, P.; Fan, C.; Han, X.; Grunwaldt, L.; Wilkinson, M.; Rodríguez, J.; Bianco, G.; Vespe, F.; Catalán, M.; Salmins, K.; del Pino, J. R.; Lim, H.-C.; Park, E.; Moore, C.; Lejba, P.; Suchodolski, T.

    2017-10-01

    The (TOPography EXperiment) TOPEX/Poseidon (T/P) altimetry mission operated for 13 years before the satellite was decommissioned in January 2006, becoming a large space debris object at an altitude of 1,340 km. Since the end of the mission, the interaction of T/P with the space environment has driven the satellite's spin dynamics. Satellite laser ranging (SLR) measurements collected from June 2014 to October 2016 allow for the satellite spin axis orientation to be determined with an accuracy of 1.7°. The spin axis coincides with the platform yaw axis (formerly pointing in the nadir direction) about which the body rotates in a counterclockwise direction. The combined photometric and SLR data collected over the 11 year time span indicates that T/P has continuously gained rotational energy at an average rate of 2.87 J/d and spins with a period of 10.73 s as of 19 October 2016. The satellite attitude model shows a variation of the cross-sectional area in the Sun direction between 8.2 m2 and 34 m2. The direct solar radiation pressure is the main factor responsible for the spin-up of the body, and the exerted photon force varies from 65 μN to 228 μN around the mean value of 138.6 μN. Including realistic surface force modeling in orbit propagation algorithms will improve the prediction accuracy, giving better conjunction warnings for scenarios like the recent close approach reported by the ILRS Space Debris Study Group—an approximate 400 m flyby between T/P and Jason-2 on 20 June 2017.

  9. Inflammatory challenge increases measures of oxidative stress in a free-ranging, long-lived mammal.

    Science.gov (United States)

    Schneeberger, Karin; Czirják, Gábor Á; Voigt, Christian C

    2013-12-15

    Oxidative stress - the imbalance between reactive oxygen species (ROS) and neutralising antioxidants - has been under debate as the main cause of ageing in aerobial organisms. The level of ROS should increase during infection as part of the activation of an immune response, leading to oxidative damage to proteins, lipids and DNA. Yet, it is unknown how long-lived organisms, especially mammals, cope with oxidative stress. Bats are known to carry a variety of zoonotic pathogens and at the same time are, despite their high mass-specific basal metabolic rate, unusually long lived, which may be partly the result of low oxidative damage of organs. Here, we asked whether an immune challenge causes oxidative stress in free-ranging bats, measuring two oxidative stress markers. We injected 20 short-tailed fruit bats (Carollia perspicillata) with bacterially derived lipopolysaccharide (LPS) and 20 individuals with phosphate-buffered saline solution (PBS) as a control. Individuals injected with LPS showed an immune reaction by increased white blood cell count after 24 h, whereas there was no significant change in leukocyte count in control animals. The biological antioxidant potential (BAP) remained the same in both groups, but reactive oxygen metabolites (ROMs) increased after treatment with LPS, indicating a significant increase in oxidative stress in animals when mounting an immune reaction toward the inflammatory challenge. Control individuals did not show a change in oxidative stress markers. We conclude that in a long-lived mammal, even high concentrations of antioxidants do not immediately neutralise free radicals produced during a cellular immune response. Thus, fighting an infection may lead to oxidative stress in bats.

  10. Wildlife speed cameras: measuring animal travel speed and day range using camera traps

    NARCIS (Netherlands)

    Rowcliffe, J.M.; Jansen, P.A.; Kays, R.; Kranstauber, B.; Carbone, C.

    2016-01-01

    Travel speed (average speed of travel while active) and day range (average speed over the daily activity cycle) are behavioural metrics that influence processes including energy use, foraging success, disease transmission and human-wildlife interactions, and which can therefore be applied to a range

  11. Investigation of hopped frequency waveforms for range and velocity measurements of radar targets

    CSIR Research Space (South Africa)

    Kathree, U

    2015-10-01

    Full Text Available In the field of radar, High Range Resolution (HRR) profiles are often used to improve target tracking accuracy in range and to allow the radar system to produce an image of an object using techniques such as inverse synthetic aperture radar (ISAR...

  12. Determination of plant growth rate and growth temperature range from measurement of physiological parameters

    Science.gov (United States)

    R. S. Criddle; B. N. Smith; L. D. Hansen; J. N. Church

    2001-01-01

    Many factors influence species range and diversity, but temperature and temperature variability are always major global determinants, irrespective of local constraints. On a global scale, the ranges of many taxa have been observed to increase and their diversity decrease with increasing latitude. On a local scale, gradients in species distribution are observable with...

  13. Food bike Rosa Mel: viabilidade do empreendimento por meio de Plano de Negócio

    OpenAIRE

    Danielle de Oliveira Barutti; Daphne de Oliveira Barutti; Ivani Ferreira da Cruz Ribeiro

    2016-01-01

    Este artigo objetiva propor a criação de um comércio itinerante de doces caseiros comercializando pão de mel, nos sabores brigadeiro, doce de leite e coco, trufas tradicionais, alfajor, café e água na modalidade Food Bike, na cidade de São Paulo. A modalidade Food Bike é o tipo de comércio itinerante em que se vendem comidas e bebidas, tendo como suporte uma bicicleta e não havendo necessidade de muito espaço para sua instalação. Utiliza-se como metodologia de análise, plano de negócio e pesq...

  14. Unionismo fiorentino negli anni Venti. L’Associazione Cristiana dei Giovani di Firenze

    Directory of Open Access Journals (Sweden)

    Letizia Pagliai

    2013-02-01

    Full Text Available Scarni sono i riferimenti storiografici sulla sezione fiorentina dell’Associazione Cristiana dei Giovani (ACDG, il corrispettivo italiano della Young Men’s Christian Association (YMCA, costituita dopo la Grande Guerra da quel Giovanni Battista Giorgini (1898-1971, noto piuttosto come talento imprenditoriale della ‘moda italiana’ negli anni del Miracolo economico. Sotto la presidenza di Giorgini (1924-1933, di formazione religiosa valdese, la sezione fiorentina dell’ACDG divenne punto di riferimento di tutta l’organizzazione italiana. Questo contributo, attraverso documenti esemplificativi, segue alcune fondamentali tappe e aspetti della vita dell’Associazione fino al 1931, quando il governo fascista ne intimò drasticamente lo scioglimento con ordinanza prefettizia.

  15. The distribution of micro zooplankton in the lagoon environments; La distribuzione del microzooplancton negli ambienti lagunari

    Energy Technology Data Exchange (ETDEWEB)

    Grenni, P.; Creo, C. [ENEA, Centro Ricerche Casaccia, Rome (Italy). Dipt. Ambiente

    1998-07-01

    The aim of this work is to verify the possible use of micro zooplankton as a biological indicator in aquatic environments. In particular, studies carried out in lagoon environments are reported, relatively to the Venice lagoon and the Pontine coastal lakes (Italy). New methodologies to assess the micro plankton component are developed and tested, particularly the concentration and count steps. The use of the same methodologies to assess nano plankton component, as biological indicator. are reported. [Italian] Nel presente lavoro viene analizzata la possibilita' di utilizzare il microzooplancton quale indicatore biologico negli ambienti acquatici (mmarini, acquadulcicoli, salmastri). In particolare, vengono riportati gli studi effettuati dall'ENEA (National Agency for New Technology, Energy and the Environment) su tale componente in ambienti lagunari, con riferimento alla laguna di Venezia e alle lagune pontine.

  16. Evaluation of knee range of motion: Correlation between measurements using a universal goniometer and a smartphone goniometric application.

    Science.gov (United States)

    Dos Santos, Rafael Aparecido; Derhon, Viviane; Brandalize, Michelle; Brandalize, Danielle; Rossi, Luciano Pavan

    2017-07-01

    Goniometers are commonly used to measure range of motion in the musculoskeletal system. Recently smartphone goniometry applications have become available to clinicians. Compare angular measures using a universal goniometer and a smartphone application. Thirty four healthy women with at least 20° of limited range of motion regarding knee extension were recruited. Knee flexion angles of the dominant limb were measured with a universal goniometer and the ROM(©) goniometric application for the smartphone. Three trained examiners compared the two assessment tools. Strong correlations were found between the measures of the universal goniometer and smartphone application (Pearson's correlation and interclass correlation coefficient > 0.93). The measurements with both devices demonstrated low dispersion and little variation. Measurements obtained using the smartphone goniometric application analyzed are as reliable as those of a universal goniometer. This application is therefore a useful tool for the evaluation of knee range of motion. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Precise Gravity Measurements for Lunar Laser Ranging at Apache Point Observatory

    Science.gov (United States)

    Crossley, D. J.; Murphy, T.; Boy, J.; De Linage, C.; Wheeler, R. D.; Krauterbluth, K.

    2012-12-01

    Lunar Laser Ranging (LLR) at Apache Point Observatory began in 2006 under the APOLLO project using a 3.5 m telescope on a 2780 m summit in New Mexico. Recent improvements in the technical operations are producing uncertainties at the few-mm level in the 1.5 x 10^13 cm separation of the solar orbits of the Earth and Moon. This level of sensitivity permits a number of important aspects of gravitational theory to be tested. Among these is the Equivalence Principle that determines the universality of free fall, tests of the time variation of the Gravitational Constant G, deviations from the inverse square law, and preferred frame effects. In 2009 APOLLO installed a superconducting gravimeter (SG) on the concrete pier under the main telescope to further constrain the deformation of the site as part of an initiative to improve all aspects of the modeling process. We have analyzed more than 3 years of high quality SG data that provides unmatched accuracy in determining the local tidal gravimetric factors for the solid Earth and ocean tide loading. With on-site gravity we have direct measurements of signals such as polar motion, and can compute global atmospheric and hydrological loading for the site using GLDAS and local hydrology models that are compared with the SG observations. We also compare the SG residuals with satellite estimates of seasonal ground gravity variations from the GRACE mission. Apache Point is visited regularly by a team from the National Geospatial-Intelligence Agency to provide absolute gravity values for the calibration of the SG and to determine secular gravity changes. Nearby GPS location P027 provides continuous position information from the Plate Boundary Observatory of Earthscope that is used to correlate gravity/height variations at the site. Unusual aspects of the data processing include corrections for the telescope azimuth that appear as small offsets at the 1 μGal level and can be removed by correlating the azimuth data with the SG

  18. A hydrogel based nanosensor with an unprecedented broad sensitivity range for pH measurements in cellular compartments

    DEFF Research Database (Denmark)

    Zhang, M.; Søndergaard, Rikke Vicki; Ek, Pramod Kumar

    2015-01-01

    Optical pH nanosensors have been applied for monitoring intracellular pH in real-time for about two decades. However, the pH sensitivity range of most nanosensors is too narrow, and measurements that are on the borderline of this range may not be correct. Furthermore, ratiometric measurements...... of acidic intracellular pH (pH nanosensors. In this paper we successfully developed a multiple sensor, a fluorophore based nanosensor, with an unprecedented broad measurement range from pH 1.4 to 7.0. In this nanosensor, three p......H-sensitive fluorophores (difluoro-Oregon Green, Oregon Green 488, and fluorescein) and one pH-insensitive fluorophore (Alexa 568) were covalently incorporated into a nanoparticle hydrogel matrix. With this broad range quadruple-labelled nanosensor all physiological relevant pH levels in living cells can be measured...

  19. Submillimeter-Wave Polarimetric Compact Ranges for Scale-Model Radar Measurements

    National Research Council Canada - National Science Library

    Coulombe, Michael J; Waldman, Jerry; Giles, R. H; Gatesman, Andrew J; Goyette, Thomas M; Nixon, William

    2002-01-01

    .... A dielectric material fabrication and characterization capability has also been developed to fabricate custom anechoic materials for the ranges as well as scaled dielectric parts for the models and clutter scenes...

  20. Validation of an in-vivo proton beam range check method in an anthropomorphic pelvic phantom using dose measurements.

    Science.gov (United States)

    Bentefour, El H; Tang, Shikui; Cascio, Ethan W; Testa, Mauro; Samuel, Deepak; Prieels, Damien; Gottschalk, Bernard; Lu, Hsiao-Ming

    2015-04-01

    In-vivo dosimetry and beam range verification in proton therapy could play significant role in proton treatment validation and improvements. In-vivo beam range verification, in particular, could enable new treatment techniques one of which could be the use of anterior fields for prostate treatment instead of opposed lateral fields as in current practice. This paper reports validation study of an in-vivo range verification method which can reduce the range uncertainty to submillimeter levels and potentially allow for in-vivo dosimetry. An anthropomorphic pelvic phantom is used to validate the clinical potential of the time-resolved dose method for range verification in the case of prostrate treatment using range modulated anterior proton beams. The method uses a 3 × 4 matrix of 1 mm diodes mounted in water balloon which are read by an ADC system at 100 kHz. The method is first validated against beam range measurements by dose extinction measurements. The validation is first completed in water phantom and then in pelvic phantom for both open field and treatment field configurations. Later, the beam range results are compared with the water equivalent path length (WEPL) values computed from the treatment planning system XIO. Beam range measurements from both time-resolved dose method and the dose extinction method agree with submillimeter precision in water phantom. For the pelvic phantom, when discarding two of the diodes that show sign of significant range mixing, the two methods agree with ±1 mm. Only a dose of 7 mGy is sufficient to achieve this result. The comparison to the computed WEPL by the treatment planning system (XIO) shows that XIO underestimates the protons beam range. Quantifying the exact XIO range underestimation depends on the strategy used to evaluate the WEPL results. To our best evaluation, XIO underestimates the treatment beam range between a minimum of 1.7% and maximum of 4.1%. Time-resolved dose measurement method satisfies the two basic

  1. Light detection and ranging measurements of wake dynamics. Part II: two-dimensional scanning

    DEFF Research Database (Denmark)

    Trujillo, Juan-José; Bingöl, Ferhat; Larsen, Gunner Chr.

    2011-01-01

    A nacelle-mounted lidar system pointing downstream has been used to measure wind turbine wake dynamics. The new measurement and data analysis techniques allow estimation of quasi-instantaneous wind fields in planes perpendicular to the rotor axis. A newly developed wake tracking procedure deliver...

  2. Inter and intra-rater reliability of mobile device goniometer in measuring lumbar flexion range of motion.

    Science.gov (United States)

    Bedekar, Nilima; Suryawanshi, Mayuri; Rairikar, Savita; Sancheti, Parag; Shyam, Ashok

    2014-01-01

    Evaluation of range of motion (ROM) is integral part of assessment of musculoskeletal system. This is required in health fitness and pathological conditions; also it is used as an objective outcome measure. Several methods are described to check spinal flexion range of motion. Different methods for measuring spine ranges have their advantages and disadvantages. Hence, a new device was introduced in this study using the method of dual inclinometer to measure lumbar spine flexion range of motion (ROM). To determine Intra and Inter-rater reliability of mobile device goniometer in measuring lumbar flexion range of motion. iPod mobile device with goniometer software was used. The part being measure i.e the back of the subject was suitably exposed. Subject was standing with feet shoulder width apart. Spinous process of second sacral vertebra S2 and T12 were located, these were used as the reference points and readings were taken. Three readings were taken for each: inter-rater reliability as well as the intra-rater reliability. Sufficient rest was given between each flexion movement. Intra-rater reliability using ICC was r=0.920 and inter-rater r=0.812 at CI 95%. Validity r=0.95. Mobile device goniometer has high intra-rater reliability. The inter-rater reliability was moderate. This device can be used to assess range of motion of spine flexion, representing uni-planar movement.

  3. Sensitivity analysis of nacelle lidar free stream wind speed measurements to wind-induction reconstruction model and lidar range configuration

    DEFF Research Database (Denmark)

    Svensson, Elin; Borraccino, Antoine; Meyer Forsting, Alexander Raul

    The sensitivity of nacelle lidar wind speed measurements to wind-induction models and lidar range configurations is studied using experimental data from the Nørrekær Enge (NKE) measurement campaign and simulated lidar data from Reynold-Averaged Navier Stokes (RANS) aerodynamic computational fluid...

  4. Aerial low-frequency hearing in captive and free-ranging harbour seals (Phoca vitulina) measured using auditory brainstem responses

    NARCIS (Netherlands)

    Lucke, K.; Hastie, Gordon D.; Ternes, Kerstin; McConnell, Bernie; Moss, Simon; Russell, Deborah J.F.; Weber, Heike; Janik, Vincent M.

    2016-01-01

    The hearing sensitivity of 18 free-ranging and 10 captive harbour seals (Phoca vitulina) to aerial sounds was measured in the presence of typical environmental noise through auditory brainstem response measurements. A focus was put on the comparative hearing sensitivity at low frequencies. Low-

  5. High dynamic range isotope ratio measurements using an analog electron multiplier

    Czech Academy of Sciences Publication Activity Database

    Williams, P.; Lorinčík, Jan; Franzreb, K.; Herwig, R.

    2013-01-01

    Roč. 45, č. 1 (2013), s. 549-552 ISSN 0142-2421 R&D Projects: GA MŠk ME 894 Institutional support: RVO:67985882 Keywords : Isotope ratios * electron multiplier * dynamic range Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 1.393, year: 2013

  6. A rede de negócios do turismo: um estudo sobre suas características e implicações estratégicas

    OpenAIRE

    Donaire, Denis; Silva,Marcos Pereira da; GASPAR, Marcos Antonio

    2009-01-01

    A atividade turística é representativa para o país em termos econômicos e sociais. A rede de negócios do turismo é formada por um complexo conjunto de elementos, que incluem os relacionamentos entre seus integrantes como parte fundamental no seu desenvolvimento. O presente trabalho busca analisar os relacionamentos existentes na rede de negócios do turismo, a fim de averiguar a qualidade dos negócios nela gerados. Para tanto, realizou-se um estudo exploratório junto às entidades representa...

  7. Reliability and Validity of Electro-Goniometric Range of Motion Measurements in Patients with Hand and Wrist Limitations.

    Science.gov (United States)

    Bashardoust Tajali, Siamak; MacDermid, Joy C; Grewal, Ruby; Young, Chris

    2016-01-01

    Cross-sectional reliability and validity study. 1. To determine intrarater, interrater and inter instrument reliabilities and validity of two digital electro goniometry to measure active wrist/finger range of motions (ROMs) in patients with limited motion. 2. To determine intrarater and interrater reliabilities of digital goniometry to measure torques of PIP passive flexion of the index finger in patients with limited motion. The study was designed in a randomized block plan on 44 patients (24 women, 20 men) with limited wrist or hand motions. Two experienced raters measured active wrist ROMs, and active and passive index PIP flexion using two digital goniometers. All measures were repeated by one rater 2-5 days after the initial measurements. The reliability measures were analyzed using Intraclass Correlation Coefficients (ICCs) and the construct validity was determined by correlation coefficients analysis between sub measures of scores; patient rated pain and function (PRWE) and quick Disabilities of the Arm, Shoulder and Hand (quick DASH) scores. The intrarater, interrater and inter instrument reliabilities were high in most ROM measures (range 0.64-0.97) for both types of electro-goniometers. The 95% limit of agreements and Bland and Altman plots did not show progressive changes. There was a significant difference in force application between the raters when performing passive ROM measures for PIP index, but the same rater produced consistent force. Most of the NK and J-Tech ROM measures were moderately correlated with the patient rated pain and function scores (range 0.32-0.63).

  8. Ultrasonic Measurement of Body Fat as a Means of Assessing Body Condition in Free-Ranging Raccoons (Procyon lotor

    Directory of Open Access Journals (Sweden)

    Elizabeth M. Stringer

    2010-01-01

    Full Text Available Assessment of body condition of free-ranging animals is important when evaluating population health and fitness. The following study used body condition scoring, ultrasound, and dissected physical measurement to assess fat stores in free-ranging raccoons (Procyon lotor. Measurements were taken of subcutaneous fat at interscapular, thoracolumbar, and lumbosacral paraspinal and ventral midline sites. These measurements were examined in relationship to body condition scores and body weight. The ultrasound technique accurately measured the subcutaneous fat of raccoons when compared to dissected physical measurement and yielded data that strongly correlated with both body condition score and body weight, with the ventral midline measurement most strongly correlated. This noninvasive method may be useful in conjunction with body condition score and body weight when assessing the nutritional status of raccoons and potentially other small carnivore species.

  9. Comparison of the measurement of heart rate in adult free-range chickens (Gallus domesticus) by auscultation and electrocardiography.

    Science.gov (United States)

    Smith, C F; Gavaghan, B J; McSweeney, D; Powell, V; Lisle, A

    2014-12-01

    To compare the heart rates of adult free-range chickens (Gallus domesticus) measured by auscultation with a stethoscope with those measured simultaneously using electrocardiography (ECG). With each bird in a standing position, estimation of the heart rate was performed by placing a mark on paper for every 4 beats for roosters and 8 beats for hens as detected by auscultation over 30 s, while simultaneous ECG was performed. Heart rates measured by auscultation showed a high correlation (r = 0.97) with those measured by ECG. There was a high correlation between the heart rates of adult free-range chickens measured by auscultation with a stethoscope and those measured simultaneously using ECG. © 2014 Australian Veterinary Association.

  10. Microwave-range shielding effectiveness measurements using a dual vibrating intrinsic reverberation chamber

    NARCIS (Netherlands)

    Leferink, Frank Bernardus Johannes; Serra, Ramiro; Schipper, H.

    2012-01-01

    Reverberation chambers create a statistical uniformly distributed field which is very useful for reliable electromagnetic interference measurements. Another advantage of these chambers is the high field strength which can be generated compared to conventional test setups. A reverberation chamber

  11. Assessment of health status by molecular measures in adults ranging from middle-aged to old

    DEFF Research Database (Denmark)

    Waaijer, M. E. C.; Westendorp, R. G. J.; Goldeck, D.

    2017-01-01

    substitution test and 15-picture learning test) with age and with cardiovascular or metabolic disease as a measure of the health status. These associations with age and health status were also tested for molecular measures (C reactive protein (CRP), numbers of senescent p16INK4a positive cells in the epidermis...... disease, as was epidermal p16INK4a positivity. All associations with cardiovascular or metabolic disease attenuated when adjusting for age. In conclusion, in middle-aged to old persons, the molecular measures tested here were more weakly associated with age and health status than functional capacity...... and dermis and putative immunosenescence (presence of CD57+ T cells)). All functional capacity measures were associated with age. CRP and epidermal p16INK4a positivity were also associated with age, but with smaller estimates. Grip strength and the Stroop test were associated with cardiovascular or metabolic...

  12. Validity and reliability of range of motion measured on smartphone (mROM)

    OpenAIRE

    Cuesta-Vargas, Antonio

    2014-01-01

    Background: Nowadays, as internet-based communication is advancing rapidly, it is getting more and more interesting to adapt clinical examination of patients to remote communication. The use of smartphone photographic is presented as a method for studying the measurement of shoulders joint ROM. Objective: To investigate the reliability of smartphone photographic measurements of upper limbs abduction angle through mRom app compared to inertial sensors as the criterion standard. Methods: ...

  13. Fluorescent Protein Based FRET Pairs with Improved Dynamic Range for Fluorescence Lifetime Measurements

    OpenAIRE

    Bobin George Abraham; Karen S Sarkisyan; Mishin, Alexander S.; Ville Santala; Tkachenko, Nikolai V.; Matti Karp

    2015-01-01

    Fluorescence Resonance Energy Transfer (FRET) using fluorescent protein variants is widely used to study biochemical processes in living cells. FRET detection by fluorescence lifetime measurements is the most direct and robust method to measure FRET. The traditional cyan-yellow fluorescent protein based FRET pairs are getting replaced by green-red fluorescent protein variants. The green-red pair enables excitation at a longer wavelength which reduces cellular autofluorescence and phototoxicit...

  14. Close Range Photogrammetry for Direct Multiple Feature Positioning Measurement without Targets

    OpenAIRE

    Gorka Kortaberria; Aitor Olarra; Alberto Tellaeche; Rikardo Minguez

    2017-01-01

    The main objective of this study is to present a new method to carry out measurements so as to improve the positioning verification step in the wind hub part dimensional validation process. This enhancement will speed up the measuring procedures for these types of parts. An industrial photogrammetry based system was applied to take advantage of its results, and new functions were added to existing capabilities. In addition to a new development based on photogrammetry modelling and image proce...

  15. New measurements of high-momentum nucleons and short-range structures in nuclei

    CERN Document Server

    Fomin, N; Asaturyan, R; Benmokhtar, F; Boeglin, W; Bosted, P; Bruell, A; Bukhari, M H S; Chudakov, E; Clasie, B; Connell, S H; Dalton, M M; Daniel, A; Day, D B; Dutta, D; Ent, R; Fassi, L El; Fenker, H; Filippone, B W; Garrow, K; Gaskell, D; Hill, C; Holt, R J; Horn, T; Jones, M K; Jourdan, J; Kalantarians, N; Keppel, C E; Kiselev, D; Kotulla, M; Lindgren, R; Lung, A F; Malace, S; Markowitz, P; McKee, P; Meekins, D G; Mkrtchyan, H; Navasardyan, T; Niculescu, G; Opper, A K; Perdrisat, C; Potterveld, D H; Punjabi, V; Qian, X; Reimer, P E; Roche, J; Rodriguez, V M; Rondon, O; Schulte, E; Seely, J; Segbefia, E; Slifer, K; Smith, G R; Solvignon, P; Tadevosyan, V; Tajima, S; Tang, L; Testa, G; Trojer, R; Tvaskis, V; Vulcan, W F; Wasko, C; Wesselmann, F R; Wood, S A; Wright, J; Zheng, X

    2011-01-01

    We present new, high-Q^2 measurements of inclusive electron scattering from high-momentum nucleons in nuclei. This yields an improved extraction of the strength of two-nucleon correlations for several nuclei, including light nuclei where clustering effects can, for the first time, be examined. The data extend to the kinematic regime where three-nucleon correlations are expected to dominate and we observe significantly greater strength in this region than previous measurements.

  16. Measured electric field intensities near electric cloud discharges detected by the Kennedy Space Center's Lightning Detection and Ranging System, LDAR

    Science.gov (United States)

    Poehler, H. A.

    1977-01-01

    For a summer thunderstorm, for which simultaneous, airborne electric field measurements and Lightning Detection and Ranging (LDAR) System data was available, measurements were coordinated to present a picture of the electric field intensity near cloud electrical discharges detected by the LDAR System. Radar precipitation echos from NOAA's 10 cm weather radar and measured airborne electric field intensities were superimposed on LDAR PPI plots to present a coordinated data picture of thunderstorm activity.

  17. Direct measurement of additional Ar-H2O vibration-rotation-tunneling bands in the millimeter-submillimeter range

    Science.gov (United States)

    Zou, Luyao; Widicus Weaver, Susanna L.

    2016-06-01

    Three new weak bands of the Ar-H2O vibration-rotation-tunneling spectrum have been measured in the millimeter wavelength range. These bands were predicted from combination differences based on previously measured bands in the submillimeter region. Two previously reported submillimeter bands were also remeasured with higher frequency resolution. These new measurements allow us to obtain accurate information on the Coriolis interaction between the 101 and 110 states. Here we report these results and the associated improved molecular constants.

  18. What range of trait levels can the Autism-Spectrum Quotient (AQ) measure reliably? An item response theory analysis.

    Science.gov (United States)

    Murray, Aja Louise; Booth, Tom; McKenzie, Karen; Kuenssberg, Renate

    2016-06-01

    It has previously been noted that inventories measuring traits that originated in a psychopathological paradigm can often reliably measure only a very narrow range of trait levels that are near and above clinical cutoffs. Much recent work has, however, suggested that autism spectrum disorder traits are on a continuum of severity that extends well into the nonclinical range. This implies a need for inventories that can capture individual differences in autistic traits from very high levels all the way to the opposite end of the continuum. The Autism-Spectrum Quotient (AQ) was developed based on a closely related rationale, but there has, to date, been no direct test of the range of trait levels that the AQ can reliably measure. To assess this, we fit a bifactor item response theory model to the AQ. Results suggested that AQ measures moderately low to moderately high levels of a general autistic trait with good measurement precision. The reliable range of measurement was significantly improved by scoring the instrument using its 4-point response scale, rather than dichotomizing responses. These results support the use of the AQ in nonclinical samples, but suggest that items measuring very low and very high levels of autistic traits would be beneficial additions to the inventory. (PsycINFO Database Record (c) 2016 APA, all rights reserved).

  19. A hydrogel based nanosensor with an unprecedented broad sensitivity range for pH measurements in cellular compartments.

    Science.gov (United States)

    Zhang, M; Søndergaard, R V; Kumar, E K P; Henriksen, J R; Cui, D; Hammershøj, P; Clausen, M H; Andresen, T L

    2015-11-07

    Optical pH nanosensors have been applied for monitoring intracellular pH in real-time for about two decades. However, the pH sensitivity range of most nanosensors is too narrow, and measurements that are on the borderline of this range may not be correct. Furthermore, ratiometric measurements of acidic intracellular pH (pH pH 1.4 to 7.0. In this nanosensor, three pH-sensitive fluorophores (difluoro-Oregon Green, Oregon Green 488, and fluorescein) and one pH-insensitive fluorophore (Alexa 568) were covalently incorporated into a nanoparticle hydrogel matrix. With this broad range quadruple-labelled nanosensor all physiological relevant pH levels in living cells can be measured without being too close to the limits of its pH-range. The nanosensor exhibits no susceptibility to interference by other intracellular ions at physiological concentrations. Due to its positive surface charge it is spontaneously internalized by HeLa cells and localizes to the lysosomes where the mean pH was measured at 4.6. This quadruple-labelled nanosensor performs accurate measurements of fluctuations of lysosomal pH in both directions, which was shown by treatment with the V-ATPase inhibitor bafilomycin A1 or its substrate ATP in HeLa cells. These measurements indicate that this novel quadruple-labelled nanosensor is a promising new tool for measuring the pH of acidic compartments in living cells.

  20. Methane emission from free-ranging sheep: a comparison of two measurement methods

    Science.gov (United States)

    Leuning, R.; Baker, S. K.; Jamie, I. M.; Hsu, C. H.; Klein, L.; Denmead, O. T.; Griffith, D. W. T.

    Methane emissions from a flock of 14, 1-year old sheep grazing on a grass and legume pasture were measured using a micrometeorological mass-balance method and a sulphur hexaflouride (SF 6) tracer technique. The former measured the mean emission, over 45 min intervals, from all the sheep within a fenced 24 m×24 m enclosure, from the enrichment of methane (CH 4) in air as it passed over the sheep. The tracer technique measured emissions from a subset of 7 individual animals over 24 h periods from measurements of CH 4 and SF 6 concentrations in air exhaled by the sheep, and from the known rate of release of SF 6 from small permeation tubes placed in the animals' rumens. Both methods gave highly similar results for 4 out of 5 days. When the species composition of dietary intake was steady during the last two days of measurement, the mean emission rate from the mass-balance method was 11.9±1.5 (SEM) g CH 4 sheep -1 d -1, while the rate from the tracer technique was 11.7±0.4 (SEM) g CH 4 sheep -1 d -1. These rates are for sheep with mean live mass of 27 kg, with a measured dry matter intake of 508 g sheep -1 d -1 and pasture dry matter digestibility of 69.5%. There was close agreement between these measurements and estimates from algorithms used to predict methane emissions from sheep for the Australian National Greenhouse Gas Inventory.

  1. Measurement of Ion Motional Heating Rates over a Range of Trap Frequencies and Temperatures

    CERN Document Server

    Bruzewicz, C D; Chiaverini, J

    2014-01-01

    We present measurements of the motional heating rate of a trapped ion at different trap frequencies and temperatures between $\\sim$0.6 and 1.5 MHz and $\\sim$4 and 295 K. Additionally, we examine the possible effect of adsorbed surface contaminants with boiling points below $\\sim$105$^{\\circ}$C by measuring the ion heating rate before and after locally baking our ion trap chip under ultrahigh vacuum conditions. We compare the heating rates presented here to those calculated from available electric-field noise models. We can tightly constrain a subset of these models based on their expected frequency and temperature scaling interdependence. Discrepancies between the measured results and predicted values point to the need for refinement of theoretical noise models in order to more fully understand the mechanisms behind motional trapped-ion heating.

  2. Close Range Photogrammetry for Direct Multiple Feature Positioning Measurement without Targets

    Directory of Open Access Journals (Sweden)

    Gorka Kortaberria

    2017-01-01

    Full Text Available The main objective of this study is to present a new method to carry out measurements so as to improve the positioning verification step in the wind hub part dimensional validation process. This enhancement will speed up the measuring procedures for these types of parts. An industrial photogrammetry based system was applied to take advantage of its results, and new functions were added to existing capabilities. In addition to a new development based on photogrammetry modelling and image processing, a measuring procedure was defined based on optical and vision system considerations. A validation against a certified procedure by means of a laser-tracker has also been established obtaining deviations of ±0.125 μm/m.

  3. Comparison of repeated measurements of methane production in sheep over 5 years and a range of measurement protocols.

    Science.gov (United States)

    Robinson, D L; Goopy, J P; Hegarty, R S; Oddy, V H

    2015-10-01

    Emissions of 710 ewes at pasture were measured for 1 h (between 09:00-16:30 h) in batches of 15 sheep in portable accumulation chambers (PAC) after an overnight fast continuing until 2 h before measurement, when the sheep had access to baled hay for 1 h. The test was used to identify a group of 104 low emitters (I-Low) and a group of 103 high emitters (I-Hi) for methane emissions adjusted for liveweight (CHawt). The 207 ewes selected at the initial study were remeasured in 5 repeat tests from 2009 through 2014 at another location. The first repeat used the original measurement protocol. Two modified protocols, each used in 2 yr, drafted unfasted sheep on the morning of the test into a yard or holding paddock until measurement. Emissions of the I-Hi sheep were higher (102-112%) than I-Low sheep in all subsequent PAC tests, with statistical significance ( sheep were measured in respiration chambers (RC); 10 high (Hi-10) and 10 low (Low-10) sheep were chosen, representing extremes (top and bottom 6.25%) for methane yield (MY; g CH/kg DMI). The Hi-10 group emitted 14% more methane (adjusted for feed intake) in a follow-up RC test, but Low-10 and Hi-10 sheep differed in only 1 of the 5 PAC tests, when Hi-10 sheep emitted less CHawt than Low-10 sheep ( = 0.002) and tended to eat less in the feeding opportunity ( = 0.085). Compared with their weight on good pasture, Low-10 sheep were proportionately lighter than Hi-10 sheep in the relatively poor pasture conditions of the initial test. Sheep identified as low emitters by PAC tests using the initial protocol did not produce less CH (mg/min) when fed a fixed level of intake in RC. Correlations between estimates of an animal's CHawt measured in PAC and CH adjusted for feed intake in RC were quite low ( = 0-19%) and significant ( sheep. With moderate repeatability over the 5 yr, PAC tests of CHawt could be a viable way to select for reduced emissions of grazing sheep. As well as exploiting any variation in MY, selecting for

  4. High resolution kilometric range optical telemetry in air by radio frequency phase measurement

    Energy Technology Data Exchange (ETDEWEB)

    Guillory, Joffray; García-Márquez, Jorge; Truong, Daniel; Wallerand, Jean-Pierre [Laboratoire Commun de Métrologie LNE-Cnam (LCM), LNE, 1 rue Gaston Boissier, 75015 Paris (France); Šmíd, Radek [Laboratoire Commun de Métrologie LNE-Cnam (LCM), LNE, 1 rue Gaston Boissier, 75015 Paris (France); Institute of Scientific Instruments of the CAS, Kralovopolska 147, 612 64 Brno (Czech Republic); Alexandre, Christophe [Centre d’Études et de Recherche en Informatique et Communications (CEDRIC), Cnam, 292 rue St-Martin, 75003 Paris (France)

    2016-07-15

    We have developed an optical Absolute Distance Meter (ADM) based on the measurement of the phase accumulated by a Radio Frequency wave during its propagation in the air by a laser beam. In this article, the ADM principle will be described and the main results will be presented. In particular, we will emphasize how the choice of an appropriate photodetector can significantly improve the telemeter performances by minimizing the amplitude to phase conversion. Our prototype, tested in the field, has proven its efficiency with a resolution better than 15 μm for a measurement time of 10 ms and distances up to 1.2 km.

  5. Characterization of short-pulse oscillators by means of a high-dynamic-range autocorrelation measurement.

    Science.gov (United States)

    Braun, A; Rudd, J V; Cheng, H; Mourou, G; Kopf, D; Jung, I D; Weingarten, K J; Keller, U

    1995-09-15

    A high-dynamic-range autocorrelation technique was used to characterize the temporal pulse shape of ultrashort laser pulses produced from four separate oscillators. These lasers included two Kerr-lens mode-locked Ti:sapphire oscillators as well as a Nd:glass and a Ti:sapphire oscillator, each passively mode locked by an antiresonant Fabry-Perot semiconductor saturable absorber. It was shown that the Nd:glass oscillator supported a pulse that was temporally clean over 8 orders of magnitude.

  6. A measurement of auroral electrons in the 1–10 MeV range

    NARCIS (Netherlands)

    Gils, J.N. van; Beek, H.F. van; Fetter, L.D. de; Hendrickx, R.V.

    Particle fluxes have been measured by means of shielded Geiger-Müller telescopes mounted m a rocket, which was launched from ESRANGE(Kiruna) into a diffuse aurora. The analysis of the dependence of the counting rates on altitude indicates that a weak flux of energetic electrons, 1–10 MeV, has been

  7. Quantifying uncertainty of measuring gully morphological evolution with close-range digital photogrammetry

    Science.gov (United States)

    Measurement of geomorphic change may be of interest to researchers and practitioners in a variety of fields including geology, geomorphology, hydrology, engineering, and soil science. Landscapes are often represented by digital elevation models. Surface models generated of the same landscape over a ...

  8. Marketing de Relacionamento: Agregando Valor ao Negócio com Big Data

    Directory of Open Access Journals (Sweden)

    Ana Cláudia Borges Coutrim dos Reis

    2016-12-01

    Full Text Available Nos últimos anos, as constantes inovações tecnológicas, o aumento exponencial do volume de dados, junto às evoluções nas tendências de consumo, geraram um cenário global de grandes desafios para as organizações. O uso de tecnologias de Big Data, para análise do volume crescente de dados, disponíveis no mundo virtual globalizado, oferece uma nova visão sobre o mercado e pode contribuir com o futuro das organizações, por meio da disponibilização de informações de qualidade que apoiarão fortemente a tomada de decisão. Nesse cenário de alta competitividade, considerar o contexto de análises de dados, com o uso de tecnologias de Big Data, pode ampliar a visão das empresas para as tendências do mercado, favorecendo a identificação de estratégias melhor direcionadas aos perfis de comportamentos e preferências de consumo. O objetivo da pesquisa é investigar como o uso das tecnologias de Big Data pode ampliar a capacidade do marketing de relacionamento das organizações, agregando valor ao negócio. Os resultados demonstram que as organizações que fazem uso das tecnologias de Big Data, conseguem melhor definir suas estratégias de marketing de relacionamento com os clientes, obtendo como resultados relacionamentos mais duradouros com o mercado e seus clientes e retornos favoráveis aos seus negócios. Em um futuro próximo, a utilização de Big Data, para ampliação das estratégias de marketing de relacionamento, serão regras de sobrevivência para as organizações. O diferencial estará na forma como o gestor interpretará as informações disponíveis e agirá para alcançar os resultados almejados.

  9. Non-destructive testing principles and accurate evaluation of the hydraulic measure impact range using the DC method

    Science.gov (United States)

    Qiu, Liming; Shen, Rongxi; Song, Dazhao; Wang, Enyuan; Liu, Zhentang; Niu, Yue; Jia, Haishan; Xia, Shankui; Zheng, Xiangxin

    2017-12-01

    An accurate and non-destructive evaluation method for the hydraulic measure impact range in coal seams is urgently needed. Aiming at the application demands, a theoretical study and field test are presented using the direct current (DC) method to evaluate the impact range of coal seam hydraulic measures. We firstly analyzed the law of the apparent resistivity response of an abnormal conductive zone in a coal seam, and then investigated the principle of non-destructive testing of the coal seam hydraulic measure impact range using the DC method, and used an accurate evaluation method based on the apparent resistivity cloud chart. Finally, taking hydraulic fracturing and hydraulic flushing as examples, field experiments were carried out in coal mines to evaluate the impact ranges. The results showed that: (1) in the process of hydraulic fracturing, coal conductivity was enhanced by high-pressure water in the coal seam, and after hydraulic fracturing, the boundary of the apparent resistivity decrease area was the boundary impact range. (2) In the process of hydraulic flushing, coal conductivity was reduced by holes and cracks in the coal seam, and after hydraulic flushing, the boundary of the apparent resistivity increase area was the boundary impact range. (3) After the implementation of the hydraulic measures, there may be some blind zones in the coal seam; in hydraulic fracturing blind zones, the apparent resistivity increased or stayed constant, while in hydraulic flushing blind zones, the apparent resistivity decreased or stayed constant. The DC method realized a comprehensive and non-destructive evaluation of the impact range of the hydraulic measures, and greatly reduced the time and cost of evaluation.

  10. Reliability of two goniometric methods of measuring active inversion and eversion range of motion at the ankle

    Directory of Open Access Journals (Sweden)

    Refshauge Kathryn M

    2006-07-01

    Full Text Available Abstract Background Active inversion and eversion ankle range of motion (ROM is widely used to evaluate treatment effect, however the error associated with the available measurement protocols is unknown. This study aimed to establish the reliability of goniometry as used in clinical practice. Methods 30 subjects (60 ankles with a wide variety of ankle conditions participated in this study. Three observers, with different skill levels, measured active inversion and eversion ankle ROM three times on each of two days. Measurements were performed with subjects positioned (a sitting and (b prone. Intra-class correlation coefficients (ICC[2,1] were calculated to determine intra- and inter-observer reliability. Results Within session intra-observer reliability ranged from ICC[2,1] 0.82 to 0.96 and between session intra-observer reliability ranged from ICC[2,1] 0.42 to 0.80. Reliability was similar for the sitting and the prone positions, however, between sessions, inversion measurements were more reliable than eversion measurements. Within session inter-observer measurements in sitting were more reliable than in prone and inversion measurements were more reliable than eversion measurements. Conclusion Our findings show that ankle inversion and eversion ROM can be measured with high to very high reliability by the same observer within sessions and with low to moderate reliability by different observers within a session. The reliability of measures made by the same observer between sessions varies depending on the direction, being low to moderate for eversion measurements and moderate to high for inversion measurements in both positions.

  11. Reliability of two goniometric methods of measuring active inversion and eversion range of motion at the ankle.

    Science.gov (United States)

    Menadue, Collette; Raymond, Jacqueline; Kilbreath, Sharon L; Refshauge, Kathryn M; Adams, Roger

    2006-07-28

    Active inversion and eversion ankle range of motion (ROM) is widely used to evaluate treatment effect, however the error associated with the available measurement protocols is unknown. This study aimed to establish the reliability of goniometry as used in clinical practice. 30 subjects (60 ankles) with a wide variety of ankle conditions participated in this study. Three observers, with different skill levels, measured active inversion and eversion ankle ROM three times on each of two days. Measurements were performed with subjects positioned (a) sitting and (b) prone. Intra-class correlation coefficients (ICC[2,1]) were calculated to determine intra- and inter-observer reliability. Within session intra-observer reliability ranged from ICC[2,1] 0.82 to 0.96 and between session intra-observer reliability ranged from ICC[2,1] 0.42 to 0.80. Reliability was similar for the sitting and the prone positions, however, between sessions, inversion measurements were more reliable than eversion measurements. Within session inter-observer measurements in sitting were more reliable than in prone and inversion measurements were more reliable than eversion measurements. Our findings show that ankle inversion and eversion ROM can be measured with high to very high reliability by the same observer within sessions and with low to moderate reliability by different observers within a session. The reliability of measures made by the same observer between sessions varies depending on the direction, being low to moderate for eversion measurements and moderate to high for inversion measurements in both positions.

  12. Measuring Pulse Rate Variability using Long-Range, Non-Contact Imaging Photoplethysmography

    Science.gov (United States)

    2016-08-20

    Photoplethysmography (PPG), first pioneered in the 1930’s, is a low cost , noninvasive method of detecting changes in blood volume using variations in...glasses, piercings, and use of skin or beauty products were recorded but not otherwise used for analysis or screening purposes. C. Experimental Design...and Lei Wang. A review of non-contact, low- cost physiological information measurement based on photoplethysmographic imaging. Annu. Int. Conf. IEEE

  13. Measurement of long-range particle correlations in small systems with the ATLAS detector

    CERN Document Server

    Milov, Alexander; The ATLAS collaboration

    2016-01-01

    Study of particle correlations is an important instrument to understand the nature of relativistic heavy ion collisions. Using a wealth of new data available from the recent heavy ion runs of Large Hadron Collider at CERN it becomes possible to study particle correlations in different collisions systems under the same conditions. The results of several recent measurement performed by the ATLAS experiment are reviewed in this proceeding. Measurements are performed in various techniques in $pp$, $p+$Pb and PbPb collisions at the energies $\\sqrt{s_{_{\\rm{NN}}}}$, $\\sqrt{s}$ from 2.76 to 13 TeV. The results are compared between the systems having the same charged particle multiplicities in the final state, but different initial geometries. Results for multiplicity correlations, two-particle and muti-particle correlations measured in different techniques are presented and discussed. The goal of these comparison is to make further steps in understanding the nature of fluctuations observed in the small collisions sy...

  14. Angstrom-range optical path-length measurement with a high-speed scanning heterodyne optical interferometer.

    Science.gov (United States)

    Riza, Nabeel A; Arain, Muzammil A

    2003-05-01

    A highly accurate method of optical path-length measurement is introduced by use of a scanning heterodyne optical interferometer with no moving parts. The instrument has demonstrated the potential to measure optical path length at angstrom resolution over continuous thickness in the micrometer range. This optical path length can be used to calculate the thickness of any material if the refractive index is known or to measure the refractive index of the material if the thickness is known. The instrument uses a single acousto-optic device in an in-line ultra-stable reflective geometry to implement rapid scanning in the microsecond domain for thickness measurements of the test medium.

  15. Radar measurements of surface deformation in the sub mm-range

    Science.gov (United States)

    Peters, Gerhard; Hort, Matthias; Gerst, Alexander; Scharff, Lea

    2016-04-01

    A portable low power Doppler radar at 24 GHz is used for volcano eruption observations since more than a decade (e.g. Hort and Seyfried, 1998, doi: 10.1029/97GL03482; Seyfried and Hort, 1999, doi: 10.1007/s004450050256; Vöge et al., 2005, doi: 10.1029/2005 EO510001, Vöge and Hort, 2009, doi: 10.1109/TGRS. 2008.2002693, Gerst et al., 2013, doi: 10.1002/jgrb.50234; Scharff et al, 2015, doi: 10.1130/G36705.1) The typical radar products are range resolved Doppler spectra containing information on the reflectivity, radial velocity and its distribution of ejected particles. Here we present the analysis of the phase of radar signals for the detection of comparably slow and small deformations of the solid surface which may occur for example prior to an eruption [Hort et al., 2010, AGU Fall meeting, Abstract V32B-03]. While the phase analysis of weather radar echoes from ground targets is established for estimating the atmospheric refractivity [Besson and du Châtelet, 2013, http://dx.doi.org/ 10.1175/ JTECH-D-12-00167.1], we consider here the variability of the atmosphere as a source of uncertainty. We describe the implementation of this technique in a dedicated compact low power FMCW system. Observations at Stromboli suggest an expansion of the vent prior to the eruption on the order of millimeter which is on the same oder as reported by [Noferini et al., 2009, doi: 10.1109/IGARSS. 2009. 5416901] and in case of Santiaguito volcano we were able to observe the post eruptive subsidence of the volcanic dome. We suggest further to resolve the range/refractivity ambiguity by using a dual frequency radar with sufficient frequency separation for utilizing the frequency dependence of refractivity.

  16. A simple and wide-range refractive index measuring approach by using a sub-micron grating

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Chun-Wei; Wu, Chun-Che; Lin, Shih-Chieh [Department of Power Mechanical Engineering, National Tsing Hua University, 101 Section 2, Kuang-Fu Road, Hsinchu 30013, Taiwan (China)

    2015-04-13

    This paper presents the design and simulation results of a high-precision low-cost refractometer that demonstrates the main advantage of a wide measurement range (1 ≤ n ≤ 2). The proposed design is based on the diffractive properties of sub-micron gratings and Snell's Law. The precision and uncertainty factors of the proposed system were tested and analyzed, revealing that the proposed refractometer demonstrates a wide measurement range with sensitivity of 10{sup −4}.

  17. Flux pinning and superconducting properties of melt-textured NEG-123 superconductor with TiO.sub.2./sub. addition

    Czech Academy of Sciences Publication Activity Database

    Muralidhar, M.; Jirsa, Miloš; Tomita, M.

    2010-01-01

    Roč. 470, 13-14 (2010), s. 592-597 ISSN 0921-4534 R&D Projects: GA ČR GA202/08/0722 Institutional research plan: CEZ:AV0Z10100520 Keywords : flux pinning, NEG-123 * high-Tc superconductors * high temperature levitation Subject RIV: BM - Solid Matter Physics ; Magnet ism Impact factor: 1.407, year: 2010

  18. Light detection and ranging measurements of wake dynamics Part I: One-dimensional Scanning

    DEFF Research Database (Denmark)

    Bingöl, Ferhat; Mann, Jakob; Larsen, Gunner Chr.

    2010-01-01

    of the wake meandering, as well as the instantaneous wake expansion expressed in a meandering frame of reference. The experiment was conducted primarily to test the simple hypothesis that the wake deficit is advected passively by the larger-than-rotor-size eddies in the atmospheric flow, and that the wake...... at the same time widens gradually, primarily because of mixing caused by small-scale atmospheric eddies. In this first paper, we focus on our new measurement technique, and test if the wake meandering follows the wind direction fluctuations, i.e. if it is advected passively in the lateral direction...

  19. Shock initiation of nano-Al/Teflon: High dynamic range pyrometry measurements

    Science.gov (United States)

    Wang, Jue; Bassett, Will P.; Dlott, Dana D.

    2017-02-01

    Laser-launched flyer plates (25 μm thick Cu) were used to impact-initiate reactive materials consisting of 40 nm Al particles embedded in TeflonAF polymer (Al/Teflon) on sapphire substrates at a stoichiometric concentration (2.3:1 Teflon:Al), as well as one-half and one-fourth that concentration. A high dynamic range emission spectrometer was used to time and spectrally resolve the emitted light and to determine graybody temperature histories with nanosecond time resolution. At 0.5 km s-1, first light emission was observed from Teflon, but at 0.6 km s-1, the emission from Al/Teflon became much more intense, so we assigned the impact threshold for Al/Teflon reactions to be 0.6 (±0.1) km s-1. The flyer plates produced a 7 ns duration steady shock drive. Emission from shocked Al/Teflon above threshold consisted of two bursts. At the higher impact velocities, the first burst started 15 ns after impact, peaked at 25 ns, and persisted for 75 ns. The second burst started at a few hundred nanoseconds and lasted until 2 μs. The 15 ns start time was exactly the time the flyer plate velocity dropped to zero after impact with sapphire. The first burst was associated with shock-triggered reactions and the second, occurring at ambient pressure, was associated with combustion of leftover material that did not react during shock. The emission spectrum was found to be a good fit to a graybody at all times, allowing temperature histories to be extracted. At 25 ns, the temperature at 0.7 km s-1 and the one-fourth Al load was 3800 K. Those temperatures increased significantly with impact velocity, up to 4600 K, but did not increase as much with Al load. A steady combustion process at 2800 (±100) K was observed in the microsecond range. The minimal dependence on Al loading indicates that these peak temperatures arise primarily from Al nanoparticles reacting almost independently, since the presence of nearby heat sources had little influence on the peak temperatures.

  20. Measurements of cnidae from sea anemones (Cnidaria: Actiniaria, III: ranges and other measures of statistical dispersion, their interrelations and taxonomic relevance

    Directory of Open Access Journals (Sweden)

    R. B. Williams

    2000-03-01

    Full Text Available This is the third of a series of papers examining the taxonomic relevance of some statistical treatments of measurements of cnidae from sea anemones (Actiniaria. Some cnida lengths from fresh tissue samples (column ectoderm, tentacles or acontia from Nematostella vectensis, Haliplanella lineata, Sagartia elegans, Metridium senile, Cereus pedunculatus, Sagartia troglodytes, Anthopleura thallia, Urticina eques and Sagartiogeton lacerates were measured. Five measures of statistical dispersion (sample standard deviation, coefficient of variation, observed sample range, standard range, and 99% probable maximum value of the standard range were calculated, and their interrelations and potential applications were appraised. It has long been the convention to use the largest and smallest cnida sizes (observed sample range from tissue samples in attempts to establish differences between actiniarian taxa. However, such data do not reflect the true extremes of a population range. In the present study, the 99% probable maximum value of the standard range for a standard abundance of 1,000 gave the greatest and, therefore, the most cautious estimate of a population range of cnida sizes for a species. This maximum standard range is the only measure of dispersion of cnida sizes that may be used validly to demonstrate that anemone specimens are of different species, and then only if there is no overlap between the extreme cnida sizes being compared. However, partial or complete overlaps of cnida size extremes do not necessarily indicate that specimens are conspecific; other taxonomic characters must also be considered. Coefficients of variation may provide valuable clues as to the homogeneity or heterogeneity of samples of cnida measurements. This paper should be read in conjunction with the first two in this series, which address the taxonomic relevance of differences between mean cnida sizes (Williams, 1996, Sci. Mar., 60: 339-351; 1998, Sci. Mar., 62: 361-372.

  1. Design, Manufacture and Testing of Capacitive Pressure Sensors for Low-Pressure Measurement Ranges

    Directory of Open Access Journals (Sweden)

    Vasileios Mitrakos

    2017-02-01

    Full Text Available This article presents the design, manufacture and testing of a capacitive pressure sensor with a high, tunable performance to low compressive loads (<10 kPa and a resolution of less than 0.5 kPa. Such a performance is required for the monitoring of treatment efficacy delivered by compression garments to treat or prevent medical conditions such as deep vein thrombosis, leg ulcers, varicose veins or hypertrophic scars. Current commercial sensors used in such medical applications have been found to be either impractical, costly or of insufficient resolution. A microstructured elastomer film of a polydimethylsiloxane (PDMS blend with a tunable Young’s modulus was used as the force-sensing dielectric medium. The resulting 18 mm × 18 mm parallel-plate capacitive pressure sensor was characterised in the range of 0.8 to 6.5 kPa. The microstructuring of the surface morphology of the elastomer film combined with the tuning of the Young’s modulus of the PDMS blend is demonstrated to enhance the sensor performance achieving a 0.25 kPa pressure resolution and a 10 pF capacitive change under 6.5 kPa compressive load. The resulting sensor holds good potential for the targeted medical application.

  2. Analysis of the properties of targets used in digital close-range photogrammetric measurement

    Science.gov (United States)

    Clarke, Timothy A.

    1994-10-01

    It is common to use some form of targeting in close range photogrammetry as there are seldom enough points on the surface of an object with sufficient contrast. Targets which have been used include: light emitting diodes; black circles on a white background; retro-reflective film; projected laser beams; projected `white light' slides; feature encoded targets; and color targets. This paper discusses the characteristics of targets. In particular the established retro- reflective target and the promising projected laser target are considered as they both offer high signal-to-noise ratios together with optimum target sizes. The performance of the targets are analyzed by use of laboratory tests, for example: (1) a retro-reflective target was placed on a rotating mount with the center of the target located on the axis of rotation and the target monitored by a CCD camera under varying conditions; and (2) a laser target was analyzed by experiments which were designed to indicate the effect of speckle by moving a flat object in a direction perpendicular to the laser beam.

  3. Nanocomposite-Based Microstructured Piezoresistive Pressure Sensors for Low-Pressure Measurement Range

    Directory of Open Access Journals (Sweden)

    Vasileios Mitrakos

    2018-01-01

    Full Text Available Piezoresistive pressure sensors capable of detecting ranges of low compressive stresses have been successfully fabricated and characterised. The 5.5 × 5 × 1.6 mm3 sensors consist of a planar aluminium top electrode and a microstructured bottom electrode containing a two-by-two array of truncated pyramids with a piezoresistive composite layer sandwiched in-between. The responses of two different piezocomposite materials, a Multiwalled Carbon Nanotube (MWCNT-elastomer composite and a Quantum Tunneling Composite (QTC, have been characterised as a function of applied pressure and effective contact area. The MWCNT piezoresistive composite-based sensor was able to detect pressures as low as 200 kPa. The QTC-based sensor was capable of detecting pressures as low as 50 kPa depending on the contact area of the bottom electrode. Such sensors could find useful applications requiring the detection of small compressive loads such as those encountered in haptic sensing or robotics.

  4. The concurrent validity and reliability of the Leg Motion system for measuring ankle dorsiflexion range of motion in older adults

    OpenAIRE

    Romero Morales, Carlos; Calvo Lobo, C?sar; Rodr?guez Sanz, David; Sanz Corbal?n, Irene; Ruiz Ruiz, Beatriz; L?pez L?pez, Daniel

    2017-01-01

    Background New reliable devices for range of motion (ROM) measures in older adults are necessary to improve knowledge about the functional capability in this population. Dorsiflexion ROM limitation is associated with ankle injuries, foot pain, lower limb disorders, loss of balance, gait control disorders and fall risk in older adults. The aim of the present study was to assess the validity and reliability of the Leg Motion device for measuring ankle dorsiflexion ROM in older adults. Methods A...

  5. Reliability and Validity of Electro-Goniometric Range of Motion Measurements in Patients with Hand and Wrist Limitations

    OpenAIRE

    Bashardoust Tajali, Siamak; MacDermid, Joy C.; Grewal, Ruby; Young, Chris

    2016-01-01

    Study Design: Cross-sectional reliability and validity study. Purpose: 1. To determine intrarater, interrater and inter instrument reliabilities and validity of two digital electro goniometry to measure active wrist/finger range of motions (ROMs) in patients with limited motion. 2. To determine intrarater and interrater reliabilities of digital goniometry to measure torques of PIP passive flexion of the index finger in patients with limited motion. Methods: The study was designed in a randomi...

  6. Francisco Ferreira Saturnino Braga: negócios e fortuna em Campos dos Goytacazes

    Directory of Open Access Journals (Sweden)

    Walter Luiz Carneiro de Mattos Pereira

    2012-12-01

    Full Text Available O artigo pretende investir no estudo da dinâmica da economia em Campos dos Goytacazes, Rio de Janeiro, nas duas décadas que antecedem a abolição da escravatura no Brasil, a partir dos negócios e da fortuna de Francisco Ferreira Saturnino Braga, proprietário de terras, escravos, usineiro, industrial, concessionário de ferrovias e banqueiro, figura-chave para se perceberem as transformações ocorridas em uma área de produção açucareira voltada para o mercado interno. As singularidades e particularidades obtidas pela observação em escala reduzida podem revelar a possibilidade de perceber uma articulação mais ampla com as estruturas de uma economia de mercado.The article intends to invest in the study of the dynamics of the economy in Campos dos Goytacazes, Rio de Janeiro, in the two decades preceding the abolition of slavery in Brazil, from the business and fortune of Francisco Ferreira Saturnino Braga, owner of land, slaves, mill owner, industrial, railroad dealer and banker, a key figure to understand the changes occurred in an area of the sugar production directs to the domestic market. The singularities and particularities obtained by observation in small scale may reveal the possibility of perceiving a broader articulation with the structures of a market economy.

  7. Food bike Rosa Mel: viabilidade do empreendimento por meio de Plano de Negócio

    Directory of Open Access Journals (Sweden)

    Danielle de Oliveira Barutti

    2016-02-01

    Full Text Available Este artigo objetiva propor a criação de um comércio itinerante de doces caseiros comercializando pão de mel, nos sabores brigadeiro, doce de leite e coco, trufas tradicionais, alfajor, café e água na modalidade Food Bike, na cidade de São Paulo. A modalidade Food Bike é o tipo de comércio itinerante em que se vendem comidas e bebidas, tendo como suporte uma bicicleta e não havendo necessidade de muito espaço para sua instalação. Utiliza-se como metodologia de análise, plano de negócio e pesquisa qualitativa exploratória para verificar o perfil do comércio itinerante e analisar o consumidor desse serviço. Foi concluído que este tipo de empreendimento é inovador, atraente, de baixo custo inicial, rentável e com taxa de retorno em torno de onze meses.

  8. Systematic Study of Acquisition Electronics with a High Dynamic Range for a Beam Loss Measurement System

    CERN Document Server

    Venturini, G G; Effinger, E; Emery, J; Zamantzas, C

    2009-01-01

    A discrete components design for a current digitizer based on the current-to-frequency converter (CFC) principle is currently under development at CERN. The design targets at higher current inputs than similar designs, with a maximum equal to 100mA and a minimum of 1nA, as required by the ionization chamber that will be employed in the Proton Synchrotron and Booster accelerators as well as in the LINAC 4. It allows the acquisition of currents of both polarities without requiring any configuration and provides fractional counts through an ADC to increase resolution. Several architectural choices are considered for the front-end circuit, including charge balance integrators, dual-integrator input stages, integrators with switchable-capacitor. Design approach and measurements are discussed in this article.

  9. O que tem sido estudado sobre escolas de negócio? A evolução dos trabalhos e a estrutura intelectual que os suporta

    Directory of Open Access Journals (Sweden)

    Isabel Cristina Scafuto

    2017-02-01

    Full Text Available O objetivo do artigo foi de mapear a estrutura intelectual da pesquisa sobre escolas de negócios a partir das referências das publicações nesse tema. O método utilizado para a avaliação da pesquisa existente foi uma análise bibliométrica de citação e cocitação, em conjunto com análise fatorial e escalonamento multidimensional (MDS. Os resultados apresentam quatro campos que orientam as pesquisas em escolas de negócio: Críticas ao currículo e à formação de executivos nas escolas de negócio; ações para a mudança das escolas de negócio; visão crítica das escolas de negócio como produtoras e disseminadoras de conhecimento; comportamento e pressões institucionais nas escolas de negócio.

  10. Reliability and validity of a weight-bearing measure of ankle dorsiflexion range of motion.

    Science.gov (United States)

    Chisholm, Martin D; Birmingham, Trevor B; Brown, Janet; Macdermid, Joy; Chesworth, Bert M

    2012-01-01

    To examine reliability and validity of the Lunge Test (LT) of dorsiflexion range of motion and determine the impact of different approaches to obtain a score on these parameters. Fifty-three patients with ankle injury/dysfunction provided initial assessment data for cross-sectional convergent and known-groups validity analysis with the Pearson coefficient (r) and paired t-test, respectively; data after 4-8 weeks of treatment for longitudinal validity analysis with coefficient r; and data 3 days later for test-retest reliability using the intra-class correlation coefficient (ICC) and minimal detectable change (MDC). LT scores were determined for the affected leg only (LTAff) and for the difference between the two limbs (LTDiff). Two strategies were used to calculate LT scores: a single series and the mean of three series of lunges. LTs were correlated with the Lower Extremity Functional Scale and Global Foot and Ankle Scale. Reliability coefficients were high (ICC=0.93-0.99). The MDC=1.0/1.5 cm, LTAff/LTDiff, respectively. Cross-sectional validity was confirmed for LTDiff (r=-0.40 to -0.50). Between-limb differences (p<0.05) supported known-groups validity. Longitudinal validity was supported for both LT change scores (r=0.39-0.63). The number of series of lunges used did not impact results. A single series of lunges produces a reliable LT score. From a validity perspective, clinicians should use LTDiff on initial assessment and either LT to assess change.

  11. Dual sightline measurements of MeV range deuterons with neutron and gamma-ray spectroscopy at JET

    DEFF Research Database (Denmark)

    Eriksson, J.; Nocente, M.; Binda, F.

    2015-01-01

    Observations made in a JET experiment aimed at accelerating deuterons to the MeV range by third harmonic radio-frequency (RF) heating coupled into a deuterium beam are reported. Measurements are based on a set of advanced neutron and gamma-ray spectrometers that, for the first time, observe the p...

  12. Reliability of the spin-T cervical goniometer in measuring cervical range of motion in an asymptomatic Indian population.

    Science.gov (United States)

    Agarwal, Shabnam; Allison, Garry T; Singer, Kevin P

    2005-09-01

    To examine the intratester reliability of the Spin-T goniometer, a cervical range of motion device, in a normal Indian population. Subjects comprised 30 healthy adults with mean age of 34 years (range, 18-65 years). The subjects were stabilized in the sitting position and the Spin-T goniometer mounted on the head of the subject. The study design was a within-subject repeated intratester reliability trial conducted for cervical range of motion in 6 directions of movement. Three measurements were taken in each direction (flexion, extension lateral flexion, and lateral rotation) per participant. Reliability coefficients, intraclass correlation coefficients, and 95% confidence interval were derived from repeated-measures analysis of variance (ANOVA). Where differences in ANOVA were detected, a paired t test was conducted and the typical error values and coefficient of variance were calculated. All repeated measures showed high intraclass correlation coefficients (all >0.96, P goniometer proved to be a reliable measuring instrument for cervical range of movement in an Indian population. The use of a laser pointer fixed to the instrument ensured a consistent neutral start position.

  13. Synthesis and Characterization of a Micelle-Based pH Nanosensor with an Unprecedented Broad Measurement Range

    DEFF Research Database (Denmark)

    Ek, Pramod Kumar; Feldborg, Lise N.; Almdal, Kristoffer

    2013-01-01

    ) carboxyfluorescein and a reference fluorophore Alexa 633 to the PAEMA shell region of the micelles. Fluorescence measurements show that these pH nanosensors are sensitive in a surprisingly broad pH range of 3.4–8.0, which is hypothesized to be due to small differences in the individual fluorophores’ local...

  14. Reproducibility of range of motion and muscle strength measurements in patients with hip osteoarthritis – an interrater study

    DEFF Research Database (Denmark)

    Poulsen, Erik; Christensen, Henrik Wulff; Penny, Jeannette Østergaard

    2012-01-01

    ABSTRACT: BACKGROUND: Assessment of range of motion (ROM) and muscle strength is fundamental in the clinical diagnosis of hip osteoarthritis (OA) but reproducibility of these measurements has mostly involved clinicians from secondary care and has rarely reported agreement parameters. Therefore, t...

  15. Linear viscoelasticity of emulsions : II. Measurements of the linear viscoelastic behavior of emulsions in the kilohertz range

    NARCIS (Netherlands)

    Oosterbroek, M.; Mellema, J.; Lopulissa, J.S.

    1981-01-01

    Linear viscoelasticity of emulsions in shear deformation in the kilohertz range is demonstrated experimentally. In order to avoid complications due to inertia effects, emulsions with small droplet sizes are studied. The preliminary measurements are interpreted as being the result of droplet

  16. Relative Orbital Element Estimation and Observability Analysis for Formation Flying Satellites using Inter-Satellite Range Measurements Only

    NARCIS (Netherlands)

    Maessen, D.C.; Gill, E.K.A.

    2010-01-01

    This paper investigates to what extent the relative orbital elements of two satellites flying in formation can be estimated making use of inter-satellite range measurements only. Since the determination of relative orbital elements does not require the orientation of the relative orbit with respect

  17. Muon momentum measurement in ICARUS-T600 LAr-TPC via multiple scattering in few-GeV range

    Science.gov (United States)

    Antonello, M.; Baibussinov, B.; Bellini, V.; Benetti, P.; Boffelli, F.; Bubak, A.; Calligarich, E.; Centro, S.; Cervi, T.; Cesana, A.; Cieslik, K.; Cocco, A. G.; Dabrowska, A.; Dermenev, A.; Falcone, A.; Farnese, C.; Fava, A.; Ferrari, A.; Gibin, D.; Gninenko, S.; Guglielmi, A.; Haranczyk, M.; Holeczek, J.; Janik, M.; Kirsanov, M.; Kisiel, J.; Kochanek, I.; Lagoda, J.; Menegolli, A.; Meng, G.; Montanari, C.; Otwinowski, S.; Picchi, P.; Pietropaolo, F.; Plonski, P.; Rappoldi, A.; Raselli, G. L.; Rossella, M.; Rubbia, C.; Sala, P.; Scaramelli, A.; Sergiampietri, F.; Spanu, M.; Stefan, D.; Sulej, R.; Szarska, M.; Terrani, M.; Torti, M.; Tortorici, F.; Varanini, F.; Ventura, S.; Vignoli, C.; Wang, H.; Yang, X.; Zalewska, A.; Zani, A.; Zaremba, K.

    2017-04-01

    The measurement of muon momentum by Multiple Coulomb Scattering is a crucial ingredient to the reconstruction of νμ CC events in the ICARUS-T600 liquid argon TPC in absence of magnetic field, as in the search for sterile neutrinos at Fermilab where ICARUS will be exposed to ~ 1 GeV Booster neutrino beam. A sample of ~ 1000 stopping muons produced by charged current interactions of CNGS νμ in the surrounding rock at the INFN Gran Sasso underground Laboratory provides an ideal benchmark in the few-GeV range since their momentum can be directly and independently obtained by the calorimetric measurement. Stopping muon momentum in the 0.5-4.5 GeV/c range has been reconstructed via Multiple Coulomb Scattering with resolution ranging from 10 to 25% depending on muon energy, track length and uniformity of the electric field in the drift volume.

  18. Long Range Weather Prediction III: Miniaturized Distributed Sensors for Global Atmospheric Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Teller, E; Leith, C; Canavan, G; Wood, L

    2001-11-13

    impacts of weather involve continuing costs of the order of 1% of GDP, a large fraction of which could be retrieved if high-fidelity predictions of two weeks forward applicability were available. These {approx}$10{sup 2} B annual savings dwarf the <$1 B costs of operating a rational, long-range weather prediction system of the type proposed.

  19. Pose and Shape Reconstruction of a Noncooperative Spacecraft Using Camera and Range Measurements

    Directory of Open Access Journals (Sweden)

    Renato Volpe

    2017-01-01

    Full Text Available Recent interest in on-orbit proximity operations has pushed towards the development of autonomous GNC strategies. In this sense, optical navigation enables a wide variety of possibilities as it can provide information not only about the kinematic state but also about the shape of the observed object. Various mission architectures have been either tested in space or studied on Earth. The present study deals with on-orbit relative pose and shape estimation with the use of a monocular camera and a distance sensor. The goal is to develop a filter which estimates an observed satellite’s relative position, velocity, attitude, and angular velocity, along with its shape, with the measurements obtained by a camera and a distance sensor mounted on board a chaser which is on a relative trajectory around the target. The filter’s efficiency is proved with a simulation on a virtual target object. The results of the simulation, even though relevant to a simplified scenario, show that the estimation process is successful and can be considered a promising strategy for a correct and safe docking maneuver.

  20. Signal processing and analysis for copper layer thickness measurement within a large variation range in the CMP process

    Science.gov (United States)

    Li, Hongkai; Zhao, Qian; Lu, Xinchun; Luo, Jianbin

    2017-11-01

    In the copper (Cu) chemical mechanical planarization (CMP) process, accurate determination of a process reaching the end point is of great importance. Based on the eddy current technology, the in situ thickness measurement of the Cu layer is feasible. Previous research studies focus on the application of the eddy current method to the metal layer thickness measurement or endpoint detection. In this paper, an in situ measurement system, which is independently developed by using the eddy current method, is applied to the actual Cu CMP process. A series of experiments are done for further analyzing the dynamic response characteristic of the output signal within different thickness variation ranges. In this study, the voltage difference of the output signal is used to represent the thickness of the Cu layer, and we can extract the voltage difference variations from the output signal fast by using the proposed data processing algorithm. The results show that the voltage difference decreases as thickness decreases in the conventional measurement range and the sensitivity increases at the same time. However, it is also found that there exists a thickness threshold, and the correlation is negative, when the thickness is more than the threshold. Furthermore, it is possible that the in situ measurement system can be used within a larger Cu layer thickness variation range by creating two calibration tables.

  1. Neck range of motion measurements using a new three-dimensional motion analysis system: validity and repeatability.

    Science.gov (United States)

    Inokuchi, Haruhi; Tojima, Michio; Mano, Hiroshi; Ishikawa, Yuki; Ogata, Naoshi; Haga, Nobuhiko

    2015-12-01

    Neck movement is important for many activities of daily living (ADL). Neck disorders, such as cervical spondylosis and whiplash can limit neck movement and ADL. The cervical range of motion (CROM) device has been recently used to measure neck range of motion (ROM); however, this measurement includes trunk motion, and therefore does not represent a pure neck ROM measurement. The authors aimed to develop a new method to establish pure neck ROM measurements during flexion, extension, lateral bending, and rotation using a three-dimensional motion analysis system, VICON. Twelve healthy participants were recruited and neck ROMs during flexion, extension, lateral bending, and rotation were measured using VICON and the CROM device. Test-retest repeatability was assessed using interclass correlation coefficients (ICCs), standard error of measurement (SEM), and minimal detectable change (MDC). Validity between two measurements was evaluated using a determination coefficient and Pearson's correlation coefficient. ICCs of neck ROM measured using VICON and the CROM device were all at substantial or almost perfect levels [VICON: ICC(1,2) = 0.786-0.962, the CROM device: ICC(1,2) = 0.736-0.950]. Both SEMs and MDCs were low in all measurement directions (VICON: SEM = 1.3°-4.5°, MDC = 3.6°-12.5°; the CROM device: SEM = 2.2°-3.9°, MDC = 6.1°-10.7°). Determination coefficients (R(2)s) and Pearson's correlation coefficients (rs) between the two measurement methods were high (R(2) = 0.607-0.745, r = 0.779-0.863). VICON is a useful system to measure neck ROMs and evaluate the efficacy of interventions, such as surgery or physiotherapeutic exercise.

  2. A Multi-hop Topology Control Based on Inter-node Range Measurement for Wireless Sensor Networks Node Localization

    Directory of Open Access Journals (Sweden)

    Ali Husein ALASIRY

    2011-10-01

    Full Text Available In centralized range-based localization techniques, sufficiency of inter-node range information received by the base station strongly affects node position estimation results. Successful data aggregation is influenced by link stability of each connection of routes, especially in a multi-hop topology model. In general, measuring the inter-node range is only performed for position determination purposes. This research introduces the use of inter-node range measurement information for link selection in a multi-hop route composition in order to increase the rate of data aggregation. Due to irregularity problems of wireless media, two areas of node communication have been considered. The regular communication area is the area in which other nodes are able to perform symmetrical communication to the node without failure. The irregular area is the area in which other nodes are seldom able to communicate. Due to its instability, some existing methods tried to avoid the irregular area completely. The proposed method, named Virtual Boundaries (VBs prioritizes these areas. The regular communication area’s nodes have high priority to be selected as link vertices; however, when there is no link candidate inside this area, nodes within the irregular area will be selected with respect to their range to the parent node. This technique resulted in a more robust multi-hop topology that can reduce isolated node numbers and increase the percentage of data collected by the base station accordingly.

  3. Polymeric nanosensors for measuring the full dynamic pH range of endosomes and lysosomes in mammalian cells

    DEFF Research Database (Denmark)

    Sun, Honghao; Andresen, Thomas Lars; Benjaminsen, Rikke Vicki

    2009-01-01

    as pH sensitive dyes, which gave a dynamic pH measurement range from 4.1-7.5. Thus, the sensors cover the pH range of almost all intracellular compartments in mammalian cells. Both neutral and cationic polyacrylamide particles were synthesized where (3-acrylamidopropyl) trimethylammonium chloride...... was used to introduce a net positive charge in the cationic particles. It was found that the positively charged particle sensors were internalized spontaneously by HepG2 cancer cells. These new pH nanosensors are potential tools in time resolved quantification of pH in the endocytic pathway of living cells....

  4. SU-F-T-184: 3D Range-Modulator for Scanned Particle Therapy: Development, Monte Carlo Simulations and Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Simeonov, Y; Penchev, P; Ringbaek, T Printz [University of Applied Sciences, Institute of Medical Physics and Radiation Protection, Giessen (Germany); Brons, S [Heidelberg Ion-Beam Therapy Center (HIT), Heidelberg (Germany); Weber, U [GSI Helmholtzzentrum fuer Schwerionenforschung GmbH, Darmstadt (Germany); Zink, K [University of Applied Sciences, Institute of Medical Physics and Radiation Protection, Giessen (Germany); University Hospital Giessen-Marburg, Marburg (Germany)

    2016-06-15

    Purpose: Active raster scanning in particle therapy results in highly conformal dose distributions. Treatment time, however, is relatively high due to the large number of different iso-energy layers used. By using only one energy and the so called 3D range-modulator irradiation times of a few seconds only can be achieved, thus making delivery of homogeneous dose to moving targets (e.g. lung cancer) more reliable. Methods: A 3D range-modulator consisting of many pins with base area of 2.25 mm2 and different lengths was developed and manufactured with rapid prototyping technique. The form of the 3D range-modulator was optimised for a spherical target volume with 5 cm diameter placed at 25 cm in a water phantom. Monte Carlo simulations using the FLUKA package were carried out to evaluate the modulating effect of the 3D range-modulator and simulate the resulting dose distribution. The fine and complicated contour form of the 3D range-modulator was taken into account by a specially programmed user routine. Additionally FLUKA was extended with the capability of intensity modulated scanning. To verify the simulation results dose measurements were carried out at the Heidelberg Ion Therapy Center (HIT) with a 400.41 MeV 12C beam. Results: The high resolution measurements show that the 3D range-modulator is capable of producing homogeneous 3D conformal dose distributions, simultaneously reducing significantly irradiation time. Measured dose is in very good agreement with the previously conducted FLUKA simulations, where slight differences were traced back to minor manufacturing deviations from the perfect optimised form. Conclusion: Combined with the advantages of very short treatment time the 3D range-modulator could be an alternative to treat small to medium sized tumours (e.g. lung metastasis) with the same conformity as full raster-scanning treatment. Further simulations and measurements of more complex cases will be conducted to investigate the full potential of the 3D

  5. A Proposal for an Out-of-Range Glycemic Population Health Safety Measure for Older Adults With Diabetes.

    Science.gov (United States)

    Pogach, Leonard; Tseng, Chin-Lin; Soroka, Orysya; Maney, Miriam; Aron, David

    2017-04-01

    To evaluate patient-level glycemic control and facility variation of a proposed out-of-range (OOR) measure (overtreatment [OT] [HbA1c 9% (75 mmol/mol)]) compared with the standard measure (SM) (HbA1c 75 years. The 47.4% of patients 65-75 years met the OOR measure (33.4% OT, 14% UT), and 65.7% met the SM. For patients aged >75 years, rates were 48.1% for OOR (39.2% OT; 8.9% UT) and 73.2% for SM. Facility-level rates for OOR for patients aged 65-75 years ranged from 33.7 to 60.4% (median 47.4%), with a strong inverse correlation (ρ = -0.41) between SM and OOR performance rankings. Among the best-performing 20% facilities on the SM, 14 of 28 ranked in the worst-performing 20% on the OOR measure; 12 of 27 of the worst-performing 20% facilities on the SM ranked in the best-performing 20% on the OOR measure. Facility rankings that are based on an SM (potential benefits) and OOR measure (potential risks) differ substantially. An OOR for high-risk populations can focus quality improvement on individual patient evaluation to reduce the risk for short-term harms. © 2017 by the American Diabetes Association.

  6. Tilted Magnetic Levitation Enables Measurement of the Complete Range of Densities of Materials with Low Magnetic Permeability.

    Science.gov (United States)

    Nemiroski, Alex; Soh, Siowling; Kwok, Sen Wai; Yu, Hai-Dong; Whitesides, George M

    2016-02-03

    Magnetic levitation (MagLev) of diamagnetic or weakly paramagnetic materials suspended in a paramagnetic solution in a magnetic field gradient provides a simple method to measure the density of small samples of solids or liquids. One major limitation of this method, thus far, has been an inability to measure or manipulate materials outside of a narrow range of densities (0.8 g/cm(3) levitated magnetically. Tilting the MagLev device relative to the gravitational vector enables the magnetic force to be decreased (relative to the magnetic force) along the axis of measurement. This approach enables many practical measurements over the entire range of densities observed in matter at ambient conditions-from air bubbles (ρ ≈ 0) to osmium and iridium (ρ ≈ 23 g/cm(3)). The ability to levitate, simultaneously, objects with a broad range of different densities provides an operationally simple method that may find application to forensic science (e.g., for identifying the composition of miscellaneous objects or powders), industrial manufacturing (e.g., for quality control of parts), or resource-limited settings (e.g., for identifying and separating small particles of metals and alloys).

  7. NegAIT: A new parser for medical text simplification using morphological, sentential and double negation.

    Science.gov (United States)

    Mukherjee, Partha; Leroy, Gondy; Kauchak, David; Rajanarayanan, Srinidhi; Romero Diaz, Damian Y; Yuan, Nicole P; Pritchard, T Gail; Colina, Sonia

    2017-05-01

    Many different text features influence text readability and content comprehension. Negation is commonly suggested as one such feature, but few general-purpose tools exist to discover negation and studies of the impact of negation on text readability are rare. In this paper, we introduce a new negation parser (NegAIT) for detecting morphological, sentential, and double negation. We evaluated the parser using a human annotated gold standard containing 500 Wikipedia sentences and achieved 95%, 89% and 67% precision with 100%, 80%, and 67% recall, respectively. We also investigate two applications of this new negation parser. First, we performed a corpus statistics study to demonstrate different negation usage in easy and difficult text. Negation usage was compared in six corpora: patient blogs (4K sentences), Cochrane reviews (91K sentences), PubMed abstracts (20K sentences), clinical trial texts (48K sentences), and English and Simple English Wikipedia articles for different medical topics (60K and 6K sentences). The most difficult text contained the least negation. However, when comparing negation types, difficult texts (i.e., Cochrane, PubMed, English Wikipedia and clinical trials) contained significantly (pstudy to show the importance of negation in distinguishing between easy and difficulty text. Five binary classifiers (Naïve Bayes, SVM, decision tree, logistic regression and linear regression) were trained using only negation information. All classifiers achieved better performance than the majority baseline. The Naïve Bayes' classifier achieved the highest accuracy at 77% (9% higher than the majority baseline). Copyright © 2017 Elsevier Inc. All rights reserved.

  8. S3 HMBC hetero: Spin-State-Selective HMBC for accurate measurement of long-range heteronuclear coupling constants

    Science.gov (United States)

    Hoeck, Casper; Gotfredsen, Charlotte H.; Sørensen, Ole W.

    2017-02-01

    A novel method, Spin-State-Selective (S3) HMBC hetero, for accurate measurement of heteronuclear coupling constants is introduced. The method extends the S3 HMBC technique for measurement of homonuclear coupling constants by appending a pulse sequence element that interchanges the polarization in 13C-1H methine pairs. This amounts to converting the spin-state selectivity from 1H spin states to 13C spin states in the spectra of long-range coupled 1H spins, allowing convenient measurement of heteronuclear coupling constants similar to other S3 or E.COSY-type methods. As usual in this type of techniques, the accuracy of coupling constant measurement is independent of the size of the coupling constant of interest. The merits of the new method are demonstrated by application to vinyl acetate, the alkaloid strychnine, and the carbohydrate methyl β-maltoside.

  9. Measuring Relativistic effects in the field of the Earth with Laser Ranged Satellites and the LARASE research program

    Science.gov (United States)

    Lucchesi, David; Anselmo, Luciano; Bassan, Massimo; Magnafico, Carmelo; Pardini, Carmen; Peron, Roberto; Pucacco, Giuseppe; Stanga, Ruggero; Visco, Massimo

    2017-04-01

    The main goal of the LARASE (LAser RAnged Satellites Experiment) research program is to obtain refined tests of Einstein's theory of General Relativity (GR) by means of very precise measurements of the round-trip time among a number of ground stations of the International Laser Ranging Service (ILRS) network and a set of geodetic satellites. These measurements are guaranteed by means of the powerful and precise Satellite Laser Ranging (SLR) technique. In particular, a big effort of LARASE is dedicated to improve the dynamical models of the LAGEOS, LAGEOS II and LARES satellites, with the objective to obtain a more precise and accurate determination of their orbit. These activities contribute to reach a final error budget that should be robust and reliable in the evaluation of the main systematic errors sources that come to play a major role in masking the relativistic precession on the orbit of these laser-ranged satellites. These error sources may be of gravitational and non-gravitational origin. It is important to stress that a more accurate and precise orbit determination, based on more reliable dynamical models, represents a fundamental prerequisite in order to reach a sub-mm precision in the root-mean-square of the SLR range residuals and, consequently, to gather benefits in the fields of geophysics and space geodesy, such as stations coordinates knowledge, geocenter determination and the realization of the Earth's reference frame. The results reached over the last year will be presented in terms of the improvements achieved in the dynamical model, in the orbit determination and, finally, in the measurement of the relativistic precessions that act on the orbit of the satellites considered.

  10. Comparative study on three highly sensitive absorption measurement techniques characterizing lithium niobate over its entire transparent spectral range.

    Science.gov (United States)

    Leidinger, M; Fieberg, S; Waasem, N; Kühnemann, F; Buse, K; Breunig, I

    2015-08-24

    We employ three highly sensitive spectrometers: a photoacoustic spectrometer, a photothermal common-path interferometer and a whispering-gallery-resonator-based absorption spectrometer, for a comparative study of measuring the absorption coefficient of nominally transparent undoped, congruently grown lithium niobate for ordinarily and extraordinarily polarized light in the wavelength range from 390 to 3800 nm. The absorption coefficient ranges from below 10(-4) cm(-1) up to 2 cm(-1). Furthermore, we measure the absorption at the Urbach tail as well as the multiphonon edge of the material by a standard grating spectrometer and a Fourier-transform infrared spectrometer, providing for the first time an absorption spectrum of the whole transparency window of lithium niobate. The absorption coefficients obtained by the three highly sensitive and independent methods show good agreement.

  11. Measurement of cervical range of motion (CROM) by electronic CROM goniometer: a test of reliability and validity.

    Science.gov (United States)

    Law, Ellis Yuk Hung; Chiu, Thomas Tai-Wing

    2013-01-01

    To investigate the reliability and validity of the Electronic Cervical Range of Motion (CROM) Goniometer in measurement of cervical spine mobility in adults with and without neck pain. A cross-sectional reliability study was conducted on 54 subjects (26 neck pain and 26 non-neck pain) aged from 20-70 years old. The Numerical Pain Rating Scale and Chinese version of Northwick Park Neck Pain Questionnaire were used to assess neck pain severity and disability respectively. The CROM was measured in sitting position except left to right rotation was measured in supine lying. All the cervical active movements were measured by using the Electronic CROM Goniometer from ARCON TM Functional Capacity Evaluation (FCE) systems. The intra-tester and inter-tester reliability were high in both normal and chronic neck pain groups with ICC coefficients ranged from 0.75-*0.92. There was significant difference in the total CROM between the normal (374.7°) and chronic neck pain group (292.6°). The ACRON cervical goniometer was found to be reliable for measuring cervical mobility in 3 planes for both normal and patient subjects. Construct validity of the goniometer was supported as the test's result documented significant difference in CROM between the control and the neck pain groups.

  12. Reliability and responsiveness of a goniometric device for measuring the range of motion in the dart-throwing motion plane.

    Science.gov (United States)

    Kasubuchi, Kenji; Dohi, Yoshihiro; Fujita, Hiroyuki; Fukumoto, Takahiko

    2018-02-26

    Dart-throwing motion (DTM) is an important component of wrist function and, consequently, has the potential to become an evaluation tool in rehabilitation. However, no measurement method is currently available to reliably measure range of motion (ROM) of the wrist in the DTM plane. To determine the reliability and responsiveness of a goniometric device to measure wrist ROM in the DTM plane. ROM of the wrist in the DTM plane was measured in 70 healthy participants. The intra-class correlation coefficient (ICC) was used to evaluate the relative reliability of measurement, and a Bland-Altman analysis conducted to establish its absolute reliability, including the 95% limits of agreement (95% LOA). The standard error of the measurement (SEM) and minimal detectable change at the 95% confidence level (MDC 95 ) were calculated as measures of responsiveness. The intra-rater ICC was 0.87, and an inter-rater ICC of 0.71. There was no evidence of a fixed or proportional bias. For intra- and inter-rater reliability, 95% LOA ranged from -13.83 to 11.12 and from -17.75 to 16.19, respectively. The SEM and MDC 95 were 4.5° and 12.4°, respectively, for intra-rater reliability, and 6.0° and 16.6°, respectively, for inter-rater reliability. The ROM of the wrist in the DTM plane was measured with fair-to-good reliability and responsiveness and, therefore, has the potential to become an evaluation tool for rehabilitation.

  13. Airborne Measurements of CO2 Column Concentration and Range Using a Pulsed Direct-Detection IPDA Lidar

    Science.gov (United States)

    Abshire, James B.; Ramanathan, Anand; Riris, Haris; Mao, Jianping; Allan, Graham R.; Hasselbrack, William E.; Weaver, Clark J.; Browell, Edward V.

    2013-01-01

    We have previously demonstrated a pulsed direct detection IPDA lidar to measure range and the column concentration of atmospheric CO2. The lidar measures the atmospheric backscatter profiles and samples the shape of the 1,572.33 nm CO2 absorption line. We participated in the ASCENDS science flights on the NASA DC-8 aircraft during August 2011 and report here lidar measurements made on four flights over a variety of surface and cloud conditions near the US. These included over a stratus cloud deck over the Pacific Ocean, to a dry lake bed surrounded by mountains in Nevada, to a desert area with a coal-fired power plant, and from the Rocky Mountains to Iowa, with segments with both cumulus and cirrus clouds. Most flights were to altitudes >12 km and had 5-6 altitude steps. Analyses show the retrievals of lidar range, CO2 column absorption, and CO2 mixing ratio worked well when measuring over topography with rapidly changing height and reflectivity, through thin clouds, between cumulus clouds, and to stratus cloud tops. The retrievals shows the decrease in column CO2 due to growing vegetation when flying over Iowa cropland as well as a sudden increase in CO2 concentration near a coal-fired power plant. For regions where the CO2 concentration was relatively constant, the measured CO2 absorption lineshape (averaged for 50 s) matched the predicted shapes to better than 1% RMS error. For 10 s averaging, the scatter in the retrievals was typically 2-3 ppm and was limited by the received signal photon count. Retrievals were made using atmospheric parameters from both an atmospheric model and from in situ temperature and pressure from the aircraft. The retrievals had no free parameters and did not use empirical adjustments, and >70% of the measurements passed screening and were used in analysis. The differences between the lidar-measured retrievals and in situ measured average CO2 column concentrations were 6 km.

  14. A Comparison of Antenna Measurements in a Near-Field Range and a Newly Renovated Short-Tapered Chamber

    Science.gov (United States)

    2016-09-01

    Research Laboratory’s (ARL) near-field range (NFR) and tapered anechoic chamber, which has been newly renovated with absorber material . ARL would like...SUPPLEMENTARY NOTES 14. ABSTRACT This study was undertaken to quantify and compare electromagnetic device (i.e., antenna) measurements using the US Army...to know the performance levels with the NFR and the newly renovated, slightly different absorber layout configuration laid out and designed by the

  15. Mathematical Model and Calibration Experiment of a Large Measurement Range Flexible Joints 6-UPUR Six-Axis Force Sensor

    Directory of Open Access Journals (Sweden)

    Yanzhi Zhao

    2016-08-01

    Full Text Available Nowadays improving the accuracy and enlarging the measuring range of six-axis force sensors for wider applications in aircraft landing, rocket thrust, and spacecraft docking testing experiments has become an urgent objective. However, it is still difficult to achieve high accuracy and large measuring range with traditional parallel six-axis force sensors due to the influence of the gap and friction of the joints. Therefore, to overcome the mentioned limitations, this paper proposed a 6-Universal-Prismatic-Universal-Revolute (UPUR joints parallel mechanism with flexible joints to develop a large measurement range six-axis force sensor. The structural characteristics of the sensor are analyzed in comparison with traditional parallel sensor based on the Stewart platform. The force transfer relation of the sensor is deduced, and the force Jacobian matrix is obtained using screw theory in two cases of the ideal state and the state of flexibility of each flexible joint is considered. The prototype and loading calibration system are designed and developed. The K value method and least squares method are used to process experimental data, and in errors of kind Ι and kind II linearity are obtained. The experimental results show that the calibration error of the K value method is more than 13.4%, and the calibration error of the least squares method is 2.67%. The experimental results prove the feasibility of the sensor and the correctness of the theoretical analysis which are expected to be adopted in practical applications.

  16. Performance Analysis of ToA-Based Positioning Algorithms for Static and Dynamic Targets with Low Ranging Measurements.

    Science.gov (United States)

    Ferreira, André G; Fernandes, Duarte; Catarino, André P; Monteiro, João L

    2017-08-19

    Indoor Positioning Systems (IPSs) for emergency responders is a challenging field attracting researchers worldwide. When compared with traditional indoor positioning solutions, the IPSs for emergency responders stand out as they have to operate in harsh and unstructured environments. From the various technologies available for the localization process, ultra-wide band (UWB) is a promising technology for such systems due to its robust signaling in harsh environments, through-wall propagation and high-resolution ranging. However, during emergency responders' missions, the availability of UWB signals is generally low (the nodes have to be deployed as the emergency responders enter a building) and can be affected by the non-line-of-sight (NLOS) conditions. In this paper, the performance of four typical distance-based positioning algorithms (Analytical, Least Squares, Taylor Series, and Extended Kalman Filter methods) with only three ranging measurements is assessed based on a COTS UWB transceiver. These algorithms are compared based on accuracy, precision and root mean square error (RMSE). The algorithms were evaluated under two environments with different propagation conditions (an atrium and a lab), for static and mobile devices, and under the human body's influence. A NLOS identification and error mitigation algorithm was also used to improve the ranging measurements. The results show that the Extended Kalman Filter outperforms the other algorithms in almost every scenario, but it is affected by the low measurement rate of the UWB system.

  17. The Value of Motion: Patient-Reported Outcome Measures Are Correlated With Range of Motion in Total Ankle Replacement.

    Science.gov (United States)

    Dekker, Travis J; Hamid, Kamran S; Federer, Andrew E; Steele, John R; Easley, Mark E; Nunley, James A; Adams, Samuel B

    2017-12-01

    The proposed benefit of total ankle replacement (TAR) over ankle fusion is preserved ankle motion, thus we hypothesized that an increase in range of motion (ROM) is positively correlated with validated patient-reported outcome measures (PROMs) in individuals receiving TAR. Patients undergoing TAR at a single academic medical center between 2007 and 2013 were evaluated in this study. In addition to a minimum of 2-year follow-up, complete preoperative and postoperative outcome measures for the Foot and Ankle Disability Index (FADI), Short Musculoskeletal Function Assessment (SMFA) Bother and Function Indices, Visual Analog Scale (VAS), and 36-Item Short Form Health Survey (SF-36) were requisite for inclusion. Standardized weightbearing maximum dorsiflexion and plantarflexion sagittal radiographs were obtained and previously described ankle and foot measurements were performed to determine ankle ROM. Eighty-eight patients met inclusion criteria (33 INBONE, 18 Salto-Talaris, 37 STAR). Mean time to final ROM radiographs was 43.8 months (range 24-89 months). All aforementioned PROMs improved between preoperative evaluation and most recent follow-up (  P dorsiflexion was positively associated with FADI, SF-36 MCS, and SMFA Function (  P motion was positively correlated with multiple PROMs. Disease-specific and generic health-related quality of life PROMs demonstrated improvement postoperatively in all domains when evaluating final total range of motion. Patients who undergo TAR for end-stage osteoarthritis with improvement in ROM demonstrate a direct correlation with improved patient-centric metrics and outcome scores. Level III: Retrospective comparative study.

  18. A wide-frequency range AC magnetometer to measure the specific absorption rate in nanoparticles for magnetic hyperthermia

    Energy Technology Data Exchange (ETDEWEB)

    Garaio, E., E-mail: eneko.garayo@ehu.es [Elektrizitatea eta Elektronika Saila, UPV/EHU, P.K. 644, Bilbao (Spain); Collantes, J.M. [Elektrizitatea eta Elektronika Saila, UPV/EHU, P.K. 644, Bilbao (Spain); Garcia, J.A. [Fisika Aplikatua II Saila, UPV/EHU, P.K. 644, Bilbao (Spain); Plazaola, F. [Elektrizitatea eta Elektronika Saila, UPV/EHU, P.K. 644, Bilbao (Spain); Mornet, S. [Institut de Chimie de la Matière Condensée de Bordeaux, UPR 9048 CNRS / Université de Bordeaux, Bordeaux (France); Couillaud, F. [Résonance Magnétique des Systèmes Biologiques, UMR 5536 CNRS / Université de Bordeaux, Bordeaux (France); Sandre, O., E-mail: olivier.sandre@enscbp.fr [Laboratoire de Chimie des Polymères Organiques, UMR 5629 CNRS / Université de Bordeaux, Bordeaux (France)

    2014-11-15

    Measurement of specific absorption rate (SAR) of magnetic nanoparticles is crucial to assert their potential for magnetic hyperthermia. To perform this task, calorimetric methods are widely used. However, those methods are not very accurate and are difficult to standardize. In this paper, we present AC magnetometry results performed with a lab-made magnetometer that is able to obtain dynamic hysteresis-loops in the AC magnetic field frequency range from 50 kHz to 1 MHz and intensities up to 24 kA m{sup −1}. In this work, SAR values of maghemite nanoparticles dispersed in water are measured by AC magnetometry. The so-obtained values are compared with the SAR measured by calorimetric methods. Both measurements, by calorimetry and magnetometry, are in good agreement. Therefore, the presented AC magnetometer is a suitable way to obtain SAR values of magnetic nanoparticles. - Highlights: • We propose AC magnetometry as a method to measure the specific absorption rate (SAR) of magnetic nanoparticles suitable for magnetic hyperthermia therapy. • We have built a lab-made AC magnetometer, which is able to measure magnetic dynamic hysteresis-loops of nanoparticle dispersions. • The device works with AC magnetic field intensities up to 24 kA m{sup −1} in a frequency range from 75 kHz to 1 MHz. • The SAR values of maghemite nanoparticles around 12 nm in magnetic diameter dispersed in water are measured by the lab-made magnetometer and different calorimetric methods. • Although all methods are in good agreement, several factors (probe location, thermal inertia, losses, etc.) make calorimetric method less accurate than AC magnetometry.

  19. Estratégia empresarial e modos de busca de novos negócios - uma análise das estratégias de busca de novos negócios em empresas brasileiras

    OpenAIRE

    Vasconcelos, Flávio Carvalho de

    2003-01-01

    O objetivo deste trabalho é a investigação de como as empresas brasileiras, no contexto nacional, empreendem a busca de novas oportunidades de negócios, identificando quais os fatores que mais claramente influenciam este comportamento. Este trabalho se estruturou a partir da operacionalização do modelo de modelo de busca estratégica e interpretação ambiental proposto por Richard Daft e Karl Weick em 1984. Foram para tanto realizadas análises estatísticas e teóricas a partir de uma pesquisa em...

  20. Short-range lidar measurement of top fruit tree canopies for pesticide applications research in the United Kingdom

    Science.gov (United States)

    Walklate, Peter J.; Richardson, G. M.; Baker, D. E.; Richards, P. A.; Cross, J. V.

    1997-07-01

    This paper presents the measurements of dwarf and semi-dwarf Cox apple trees with a tractor-mounted LIDAR (light detecting and ranging). An analysis is presented which derives structural parameters of the canopy for use in pesticide spraying research by considering the number flux of LIDAR scans intercepted by the crop in a known spatial segment. LIDAR measurements of the crop area normalized by the horizontal projected area of the crop are compared with measurements derived from a destructive sampling method. The distributions of local crop area density and crop interception probability are also presented. Crop area density distribution can be used to estimate the deposition distribution of spray by utilizing a suitable transport and deposition model. Alternatively, crop interception probability distribution can be used as a first order estimate of the spray deposition distribution by making an analogy between light and spray transmission.

  1. [Research on the range of motion measurement system for spine based on LabVIEW image processing technology].

    Science.gov (United States)

    Li, Xiaofang; Deng, Linhong; Lu, Hu; He, Bin

    2014-08-01

    A measurement system based on the image processing technology and developed by LabVIEW was designed to quickly obtain the range of motion (ROM) of spine. NI-Vision module was used to pre-process the original images and calculate the angles of marked needles in order to get ROM data. Six human cadaveric thoracic spine segments T7-T10 were selected to carry out 6 kinds of loads, including left/right lateral bending, flexion, extension, cis/counterclockwise torsion. The system was used to measure the ROM of segment T8-T9 under the loads from 1 Nm to 5 Nm. The experimental results showed that the system is able to measure the ROM of the spine accurately and quickly, which provides a simple and reliable tool for spine biomechanics investigators.

  2. Earth gravity field modeling and relativistic measurements with laser-ranged satellites and the LARASE research program

    Science.gov (United States)

    Pucacco, Giuseppe; Lucchesi, David; Anselmo, Luciano; Bassan, Massimo; Magnafico, Carmelo; Pardini, Carmen; Peron, Roberto; Stanga, Ruggero; Visco, Massimo

    2017-04-01

    The importance of General Relativity (GR) for space geodesy — and for geodesy in general — is well known since several decades and it has been confirmed by a number of very significant results. For instance, GR plays a fundamental role for the following very notable techniques: Satellite-and-Lunar Laser Ranging (SLR/LLR), Very Long Baseline Interferometry (VLBI), Doppler Orbitography and Radio-positioning Integrated by Satellite (DORIS), and Global Navigation Satellite Systems (GNSS). Each of these techniques is intimately and closely related with both GR and geodesy, i.e. they are linked in a loop where benefits in one field provide positive improvements in the other ones. A common ingredient for a suitable and reliable use of each of these techniques is represented by the knowledge of the Earth's gravitational field, both in its static and temporal dependence. Spaceborne gravimetry, with the inclusion of accelerometers and gradiometers on board dedicated satellites, together with microwave links between satellites and GPS measurements, have allowed a huge improvement in the determination of the Earth's geopotential during the last 15 years. In the near future, further improvements are expected in this knowledge thanks to the inclusion of laser inter-satellite link and the possibility to compare frequency and atomic standards by a direct use of atomic clocks, both on the Earth's surface and in space. Such results will be also important for the possibility to further improve the GR tests and measurements in the field of the Earth with laser-ranged satellites in order to compare the predictions of Einstein's theory with those of other (proposed) relativistic theories for the interpretation of the gravitational interaction. Within the present paper we describe the state of the art of such measurements with geodetic satellites, as the two LAGEOS and LARES, and we discuss the effective impact of the systematic errors of gravitational origin on the measurement of

  3. Entropy measures, entropy estimators, and their performance in quantifying complex dynamics: Effects of artifacts, nonstationarity, and long-range correlations

    Science.gov (United States)

    Xiong, Wanting; Faes, Luca; Ivanov, Plamen Ch.

    2017-06-01

    Entropy measures are widely applied to quantify the complexity of dynamical systems in diverse fields. However, the practical application of entropy methods is challenging, due to the variety of entropy measures and estimators and the complexity of real-world time series, including nonstationarities and long-range correlations (LRC). We conduct a systematic study on the performance, bias, and limitations of three basic measures (entropy, conditional entropy, information storage) and three traditionally used estimators (linear, kernel, nearest neighbor). We investigate the dependence of entropy measures on estimator- and process-specific parameters, and we show the effects of three types of nonstationarities due to artifacts (trends, spikes, local variance change) in simulations of stochastic autoregressive processes. We also analyze the impact of LRC on the theoretical and estimated values of entropy measures. Finally, we apply entropy methods on heart rate variability data from subjects in different physiological states and clinical conditions. We find that entropy measures can only differentiate changes of specific types in cardiac dynamics and that appropriate preprocessing is vital for correct estimation and interpretation. Demonstrating the limitations of entropy methods and shedding light on how to mitigate bias and provide correct interpretations of results, this work can serve as a comprehensive reference for the application of entropy methods and the evaluation of existing studies.

  4. Critical current measurements of high-temperature superconducting short samples at a wide range of temperatures and magnetic fields.

    Science.gov (United States)

    Ma, Hongjun; Liu, Huajun; Liu, Fang; Zhang, Huahui; Ci, Lu; Shi, Yi; Lei, Lei

    2018-01-01

    High-Temperature Superconductors (HTS) are potential materials for high-field magnets, low-loss transmission cables, and Superconducting Magnetic Energy Storage (SMES) due to their high upper critical magnetic field (H c2 ) and critical temperature (T c ). The critical current (I c ) of HTS, which is one of the most important parameters for superconductor application, depends strongly on the magnetic fields and temperatures. A new I c measurement system that can carry out accurate I c measurement for HTS short samples with various temperatures (4.2-80 K), magnetic fields (0-14 T), and angles of the magnetic field (0°-90°) has been developed. The I c measurement system mainly consists of a measurement holder, temperature-control system, background magnet, test cryostat, data acquisition system, and DC power supply. The accuracy of temperature control is better than ±0.1 K over the 20-80 K range and ±0.05 K when measured below 20 K. The maximum current is over 1000 A with a measurement uncertainty of 1%. The system had been successfully used for YBa 2 Cu 3 O 7-x (YBCO) tapes I c determination with different temperatures and magnetic fields.

  5. Current Practices of Measuring and Reference Range Reporting of Free and Total Testosterone in the United States.

    Science.gov (United States)

    Le, Margaret; Flores, David; May, Danica; Gourley, Eric; Nangia, Ajay K

    2016-05-01

    The evaluation and management of male hypogonadism should be based on symptoms and on serum testosterone levels. Diagnostically this relies on accurate testing and reference values. Our objective was to define the distribution of reference values and assays for free and total testosterone by clinical laboratories in the United States. Upper and lower reference values, assay methodology and source of published reference ranges were obtained from laboratories across the country. A standardized survey was reviewed with laboratory staff via telephone. Descriptive statistics were used to tabulate results. We surveyed a total of 120 laboratories in 47 states. Total testosterone was measured in house at 73% of laboratories. At the remaining laboratories studies were sent to larger centralized reference facilities. The mean ± SD lower reference value of total testosterone was 231 ± 46 ng/dl (range 160 to 300) and the mean upper limit was 850 ± 141 ng/dl (range 726 to 1,130). Only 9% of laboratories where in-house total testosterone testing was performed created a reference range unique to their region. Others validated the instrument recommended reference values in a small number of internal test samples. For free testosterone 82% of laboratories sent testing to larger centralized reference laboratories where equilibrium dialysis and/or liquid chromatography with mass spectrometry was done. The remaining laboratories used published algorithms to calculate serum free testosterone. Reference ranges for testosterone assays vary significantly among laboratories. The ranges are predominantly defined by limited population studies of men with unknown medical and reproductive histories. These poorly defined and variable reference values, especially the lower limit, affect how clinicians determine treatment. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  6. Long-range weight functions in fundamental measure theory of the non-uniform hard-sphere fluid.

    Science.gov (United States)

    Hansen-Goos, Hendrik

    2016-06-22

    We introduce long-range weight functions to the framework of fundamental measure theory (FMT) of the non-uniform, single-component hard-sphere fluid. While the range of the usual weight functions is equal to the hard-sphere radius R, the modified weight functions have range 3R. Based on the augmented FMT, we calculate the radial distribution function g(r) up to second order in the density within Percus' test particle theory. Consistency of the compressibility and virial routes on this level allows us to determine the free parameter γ of the theory. As a side result, we obtain a value for the fourth virial coefficient B 4 which deviates by only 0.01% from the exact result. The augmented FMT is tested for the dense fluid by comparing results for g(r) calculated via the test particle route to existing results from molecular dynamics simulations. The agreement at large distances (r  >  6R) is significantly improved when the FMT with long-range weight functions is used. In order to improve agreement close to contact (r  =  2R) we construct a free energy which is based on the accurate Carnahan-Starling equation of state, rather than the Percus-Yevick compressibility equation underlying standard FMT.

  7. Modelos de negócio na economia compartilhada: uma investigação multi-caso

    OpenAIRE

    Villanova, Ana Luisa

    2015-01-01

    A economia compartilhada teve origem na década de 1990 nos Estados Unidos impulsionada pelos avanços tecnológicos que propiciaram a redução dos custos das transações on-line peer-to-peer (SHIRKY, 2008), viabilizando a criação de novos modelos de negócio baseados na troca e no compartilhamento de bens e serviços entre pessoas desconhecidas (SCHOR, 2015). A economia compartilhada é constituída por práticas comerciais que possibilitam o acesso a bens e serviços, sem que haja, necessariamente, a ...

  8. Turismo de Negócios. Convention & Visitors Bureau na Região Centro de Portugal

    OpenAIRE

    Marques, Jorge Humberto Soares

    2014-01-01

    Tese de doutoramento em Turismo, Lazer e Cultura, apresentada ao Departamento de Geografia da Faculdade de Letras da Universidade de Coimbra Para além do alojamento, dos espaços para reuniões, das acessibilidades e das organizações locais de apoio (como é o caso dos Convention & Visitors Bureaux) representarem uma grande importância no momento de escolha do local para realizar ou assistir a uma conferência ou outro evento de negócios, também a atratividade do destino, relacionada com as at...

  9. Sucesso, mídia de negócios e a cultura do management no Brasil

    OpenAIRE

    Ituassu, Cristiana Trindade; Tonelli, Maria José

    2014-01-01

    A lógica das modernas práticas de gestão ultrapassou a esfera econômica e disseminou-se como modelo de conduta para outras esferas da vida social, em um processo denominado management ou cultura do management, intensamente difundido após a Segunda Guerra Mundial. Ao se expandir para países em desenvolvimento, argumentamos que esse processo trouxe, entre outros valores, modelos de sucesso que se propagaram a partir da mídia de negócios. A mídia, entendida como comunicação de massa, possibilita...

  10. Airborne Measurements of CO2 Column Concentration and Range Using a Pulsed Direct-Detection IPDA Lidar

    Directory of Open Access Journals (Sweden)

    James B. Abshire

    2013-12-01

    Full Text Available We have previously demonstrated a pulsed direct detection IPDA lidar to measure range and the column concentration of atmospheric CO2. The lidar measures the atmospheric backscatter profiles and samples the shape of the 1,572.33 nm CO2 absorption line. We participated in the ASCENDS science flights on the NASA DC-8 aircraft during August 2011 and report here lidar measurements made on four flights over a variety of surface and cloud conditions near the US. These included over a stratus cloud deck over the Pacific Ocean, to a dry lake bed surrounded by mountains in Nevada, to a desert area with a coal-fired power plant, and from the Rocky Mountains to Iowa, with segments with both cumulus and cirrus clouds. Most flights were to altitudes >12 km and had 5–6 altitude steps. Analyses show the retrievals of lidar range, CO2 column absorption, and CO2 mixing ratio worked well when measuring over topography with rapidly changing height and reflectivity, through thin clouds, between cumulus clouds, and to stratus cloud tops. The retrievals shows the decrease in column CO2 due to growing vegetation when flying over Iowa cropland as well as a sudden increase in CO2 concentration near a coal-fired power plant. For regions where the CO2 concentration was relatively constant, the measured CO2 absorption lineshape (averaged for 50 s matched the predicted shapes to better than 1% RMS error. For 10 s averaging, the scatter in the retrievals was typically 2–3 ppm and was limited by the received signal photon count. Retrievals were made using atmospheric parameters from both an atmospheric model and from in situ temperature and pressure from the aircraft. The retrievals had no free parameters and did not use empirical adjustments, and >70% of the measurements passed screening and were used in analysis. The differences between the lidar-measured retrievals and in situ measured average CO2 column concentrations were <1.4 ppm for flight measurement altitudes >6

  11. The concurrent validity and reliability of the Leg Motion system for measuring ankle dorsiflexion range of motion in older adults.

    Science.gov (United States)

    Romero Morales, Carlos; Calvo Lobo, César; Rodríguez Sanz, David; Sanz Corbalán, Irene; Ruiz Ruiz, Beatriz; López López, Daniel

    2017-01-01

    New reliable devices for range of motion (ROM) measures in older adults are necessary to improve knowledge about the functional capability in this population. Dorsiflexion ROM limitation is associated with ankle injuries, foot pain, lower limb disorders, loss of balance, gait control disorders and fall risk in older adults. The aim of the present study was to assess the validity and reliability of the Leg Motion device for measuring ankle dorsiflexion ROM in older adults. Adescriptive repeated-measures study was designed to test the reliability of Leg Motion in thirty-three healthy elderly patients older than 65 years. The subjects had to meet the following inclusion and exclusion criteria in their medical records: older than 65 years; no lower extremity injury for at least one year prior to evaluation (meniscopathy, or fractures) and any chronic injuries (e.g., osteoarthritis); no previous hip, knee or ankle surgery; no neuropathic alterations and no cognitive conditions (e.g., Alzheimer's disease or dementia). Participants were recruited through the person responsible for the physiotherapist area from a nursing center. The subjects were evaluated in two different sessions at the same time of day, and there was a break of two weeks between sessions. To test the validity of the Leg Motion system, the participants were measured in a weight-bearing lunge position using a classic goniometer with 1° increments, a smartphone with an inclinometer standard app (iPhone 5S®) with 1° increments and a measuring tape that could measure 0.1 cm. All testing was performed while the patients were barefoot. The researcher had ten years of experience as a physiotherapist using goniometer, tape measure and inclinometer devices. Mean values and standard deviations were as follows: Leg Motion (right 5.15 ± 3.08; left 5.19 ± 2.98), tape measure (right 5.12 ± 3.08; left 5.12 ± 2.80), goniometer (right 45.87° ± 4.98; left 44.50° ± 5.54) and inclinometer app (right

  12. The concurrent validity and reliability of the Leg Motion system for measuring ankle dorsiflexion range of motion in older adults

    Directory of Open Access Journals (Sweden)

    Carlos Romero Morales

    2017-01-01

    Full Text Available Background New reliable devices for range of motion (ROM measures in older adults are necessary to improve knowledge about the functional capability in this population. Dorsiflexion ROM limitation is associated with ankle injuries, foot pain, lower limb disorders, loss of balance, gait control disorders and fall risk in older adults. The aim of the present study was to assess the validity and reliability of the Leg Motion device for measuring ankle dorsiflexion ROM in older adults. Methods Adescriptive repeated-measures study was designed to test the reliability of Leg Motion in thirty-three healthy elderly patients older than 65 years. The subjects had to meet the following inclusion and exclusion criteria in their medical records: older than 65 years; no lower extremity injury for at least one year prior to evaluation (meniscopathy, or fractures and any chronic injuries (e.g., osteoarthritis; no previous hip, knee or ankle surgery; no neuropathic alterations and no cognitive conditions (e.g., Alzheimer’s disease or dementia. Participants were recruited through the person responsible for the physiotherapist area from a nursing center. The subjects were evaluated in two different sessions at the same time of day, and there was a break of two weeks between sessions. To test the validity of the Leg Motion system, the participants were measured in a weight-bearing lunge position using a classic goniometer with 1° increments, a smartphone with an inclinometer standard app (iPhone 5S® with 1° increments and a measuring tape that could measure 0.1 cm. All testing was performed while the patients were barefoot. The researcher had ten years of experience as a physiotherapist using goniometer, tape measure and inclinometer devices. Results Mean values and standard deviations were as follows: Leg Motion (right 5.15 ± 3.08; left 5.19 ± 2.98, tape measure (right 5.12 ± 3.08; left 5.12 ± 2.80, goniometer (right 45.87° ± 4.98; left 44

  13. Validity and intra-rater reliability of an android phone application to measure cervical range-of-motion.

    Science.gov (United States)

    Quek, June; Brauer, Sandra G; Treleaven, Julia; Pua, Yong-Hao; Mentiplay, Benjamin; Clark, Ross Allan

    2014-04-17

    Concurrent validity and intra-rater reliability using a customized Android phone application to measure cervical-spine range-of-motion (ROM) has not been previously validated against a gold-standard three-dimensional motion analysis (3DMA) system. Twenty-one healthy individuals (age:31 ± 9.1 years, male:11) participated, with 16 re-examined for intra-rater reliability 1-7 days later. An Android phone was fixed on a helmet, which was then securely fastened on the participant's head. Cervical-spine ROM in flexion, extension, lateral flexion and rotation were performed in sitting with concurrent measurements obtained from both a 3DMA system and the phone.The phone demonstrated moderate to excellent (ICC = 0.53-0.98, Spearman ρ = 0.52-0.98) concurrent validity for ROM measurements in cervical flexion, extension, lateral-flexion and rotation. However, cervical rotation demonstrated both proportional and fixed bias. Excellent intra-rater reliability was demonstrated for cervical flexion, extension and lateral flexion (ICC = 0.82-0.90), but poor for right- and left-rotation (ICC = 0.05-0.33) using the phone. Possible reasons for the outcome are that flexion, extension and lateral-flexion measurements are detected by gravity-dependent accelerometers while rotation measurements are detected by the magnetometer which can be adversely affected by surrounding magnetic fields. The results of this study demonstrate that the tested Android phone application is valid and reliable to measure ROM of the cervical-spine in flexion, extension and lateral-flexion but not in rotation likely due to magnetic interference. The clinical implication of this study is that therapists should be mindful of the plane of measurement when using the Android phone to measure ROM of the cervical-spine.

  14. Beam-based measurements of long-range transverse wakefields in the Compact Linear Collider main-linac accelerating structure

    Directory of Open Access Journals (Sweden)

    Hao Zha

    2016-01-01

    Full Text Available The baseline design of CLIC (Compact Linear Collider uses X-band accelerating structures for its main linacs. In order to maintain beam stability in multibunch operation, long-range transverse wakefields must be suppressed by 2 orders of magnitude between successive bunches, which are separated in time by 0.5 ns. Such strong wakefield suppression is achieved by equipping every accelerating structure cell with four damping waveguides terminated with individual rf loads. A beam-based experiment to directly measure the effectiveness of this long-range transverse wakefield and benchmark simulations was made in the FACET test facility at SLAC using a prototype CLIC accelerating structure. The experiment showed good agreement with the simulations and a strong suppression of the wakefields with an unprecedented minimum resolution of 0.1  V/(pC mm m.

  15. Measurement of the Range Component Directional Signature in a DRIFT-II Detector using 252Cf Neutrons

    CERN Document Server

    Burgos, S; Forbes, J; Ghag, C; Gold, M; Hagemann, C; Kudryavtsev, V A; Lawson, T B; Loomba, D; Majewski, P; Muna, D; Murphy, A St J; Nicklin, G G; Paling, S M; Petkov, A; Plank, S J S; Robinson, M; Sanghi, N; Snowden-Ifft, D P; Spooner, N J C; Turk, J; Tziaferi, E

    2008-01-01

    The DRIFT collaboration utilizes low pressure gaseous detectors to search for WIMP dark matter with directional signatures. A 252Cf neutron source was placed on each of the principal axes of a DRIFT detector in order to test its ability to measure directional signatures from the three components of very low energy (~keV/amu) recoil ranges. A high trigger threshold and the event selection procedure ensured that only sulfur recoils were analyzed. Sulfur recoils produced in the CS2 target gas by the 252Cf source closely match those expected from massive WIMP induced sulfur recoils. For each orientation of the source a directional signal from the range components was observed, indicating that the detector is directional along all 3 axes. An analysis of these results yields an optimal orientation for DRIFT detectors when searching for a directional signature from WIMPs. Additional energy dependent information is provided to aid in understanding this effect.

  16. Measurements of the conduction of heat in water vapor, nitrogen and mixtures of these gases in an extended temperature range

    Science.gov (United States)

    Frohn, A.; Westerdorf, M.

    Experimental and analytical results are presented from trials with heat conduction in water vapor, nitrogen, and mixtures of the two in a cylindrical heat transfer cell. The pressures examined ranged from 100-0.01 mbar, corresponding to Knudsen numbers of 0.01-100. Formulations are defined for the continuum conditions, the free molecule conditions, the transition region, and the momentum equation solution. Experimentation with an instrumented configuration of an inner and outer cylinder over the temperature range 300-725 K is described, noting the use of a vacuum around the inner, gas-filled container in order to measure the radiative heat losses. The results are useful for predicting heat transfer in high altitude flight or among small droplets in natural fogs, cooling towers, and combustion chambers.

  17. Validity and test-retest reliability of manual goniometers for measuring passive hip range of motion in femoroacetabular impingement patients.

    Directory of Open Access Journals (Sweden)

    Nussbaumer Silvio

    2010-08-01

    Full Text Available Abstract Background The aims of this study were to evaluate the construct validity (known group, concurrent validity (criterion based and test-retest (intra-rater reliability of manual goniometers to measure passive hip range of motion (ROM in femoroacetabular impingement patients and healthy controls. Methods Passive hip flexion, abduction, adduction, internal and external rotation ROMs were simultaneously measured with a conventional goniometer and an electromagnetic tracking system (ETS on two different testing sessions. A total of 15 patients and 15 sex- and age-matched healthy controls participated in the study. Results The goniometer provided greater hip ROM values compared to the ETS (range 2.0-18.9 degrees; P P Conclusions The present study suggests that goniometer-based assessments considerably overestimate hip joint ROM by measuring intersegmental angles (e.g., thigh flexion on trunk for hip flexion rather than true hip ROM. It is likely that uncontrolled pelvic rotation and tilt due to difficulties in placing the goniometer properly and in performing the anatomically correct ROM contribute to the overrating of the arc of these motions. Nevertheless, conventional manual goniometers can be used with confidence for longitudinal assessments in the clinic.

  18. Intra-examiner reliability of measurements of ankle range of motion using a modified inclinometer: a pilot study

    Science.gov (United States)

    Tavares, Patricia; Landsman, Victoria; Wiltshire, Leslie

    2017-01-01

    A modified inclinometer was designed for measuring total ankle range of motion (ROM) in the standing position for a large future study. The purpose of this pilot study was to assess the intra-examiner reliability of this new device in order to see if the examiner would be able to produce equally reliable measurements with this instrument as with a routinely used goniometer. Nineteen young healthy individuals took part in the pilot. The same examiner took the ROM measurements using both devices twice on the same day and one further time 2 or 3 days later. Test-retest reliability was measured using the intraclass correlation coefficient (ICC). The ICC values were 0.86 (95% CI=[0.67; 0.94]) and 0.83 (95% CI=[0.61; 0.93]) for the measurements taken with the goniometer on the same day and for those on two different days. The corresponding values for the modified inclinometer were 0.88 (95% CI=[0.72;0.95]) and 0.81 (95% CI=[0.57; 0.92]). Both instruments were found to have very good test-retest reliability. PMID:28928495

  19. Validity of an Alternate Hand Behind Back Shoulder Range of Motion Measurement in Patients With Shoulder Pain and Movement Dysfunction.

    Science.gov (United States)

    Satpute, Kiran H; Hall, Toby; Adanani, Aditi

    2018-02-23

    The purpose of this study was to determine the criterion-related validity of a novel method of measuring hand behind back (HBB) shoulder range of motion (ROM) for evaluating pain and disability in people with shoulder pain and movement impairment. This cross-sectional study design evaluated shoulder ROM, pain, fear-avoidance beliefs, and disability in 60 people (aged 35-70 years, 31 male) with chronic unilateral shoulder dysfunction (mean duration 15.73 weeks). Shoulder HBB ROM was measured with a bubble inclinometer in a manner that did not require the patient to disrobe. Correlations were sought between HBB ROM and other shoulder movements, as well as scores recorded on the Shoulder Pain and Disability Index (SPADI), visual analogue scale for pain, Fear Avoidance Beliefs Questionnaire (FABQ), and duration of symptoms. Restriction of HBB movement was significantly correlated with SPADI total disability score (r = 0.39, P shoulder movements. These findings suggest that this novel method of measuring HBB ROM could be used as a functional outcome measure in the evaluation of patients with shoulder disorders. This method could be considered as an additional or alternative where there are challenges in measuring HBB because of restrictions in undressing a patient, such as for cultural reasons. Copyright © 2018. Published by Elsevier Inc.

  20. Micro-Viscometer for Measuring Shear-Varying Blood Viscosity over a Wide-Ranging Shear Rate

    Science.gov (United States)

    Kim, Byung Jun; Lee, Seung Yeob; Jee, Solkeun; Atajanov, Arslan; Yang, Sung

    2017-01-01

    In this study, a micro-viscometer is developed for measuring shear-varying blood viscosity over a wide-ranging shear rate. The micro-viscometer consists of 10 microfluidic channel arrays, each of which has a different micro-channel width. The proposed design enables the retrieval of 10 different shear rates from a single flow rate, thereby enabling the measurement of shear-varying blood viscosity with a fixed flow rate condition. For this purpose, an optimal design that guarantees accurate viscosity measurement is selected from a parametric study. The functionality of the micro-viscometer is verified by both numerical and experimental studies. The proposed micro-viscometer shows 6.8% (numerical) and 5.3% (experimental) in relative error when compared to the result from a standard rotational viscometer. Moreover, a reliability test is performed by repeated measurement (N = 7), and the result shows 2.69 ± 2.19% for the mean relative error. Accurate viscosity measurements are performed on blood samples with variations in the hematocrit (35%, 45%, and 55%), which significantly influences blood viscosity. Since the blood viscosity correlated with various physical parameters of the blood, the micro-viscometer is anticipated to be a significant advancement for realization of blood on a chip. PMID:28632151

  1. Measures of range of motion and strength among healthy women with differing quality of lower extremity movement during the lateral step-down test

    National Research Council Canada - National Science Library

    Rabin, Alon; Kozol, Zvi

    2010-01-01

    Cross-sectional. To determine the association between hip and ankle range-of-motion measures, as well as measures of hip muscle strength, with measures of quality of lower extremity movement, as assessed visually...

  2. Impact of blood volume changes within the human skin on the diffuse reflectance measurements in visible and NIR spectral ranges

    Science.gov (United States)

    Zherebtsov, Evgeny; Bykov, Alexander; Popov, Alexey; Doronin, Alexander; Meglinski, Igor

    2017-03-01

    We consider changes in the volume of blood and oxygen saturation caused by a pulse wave and their influence on the diffuse reflectance spectra in the visible/NIR spectral range. CUDA-based Monte-Carlo model was used for routine simulation of detector depth sensitivity (sampling volume) and skin spectra, and their variations associated with physiological changes in the human skin. The results presented in the form of animated graphs of sampling volume changes for scaling of the parameters of the main human skin layers related to the results of experimental measurements are of particular interest for pulse oximetry, photoplethysmography, Doppler flowmetry, reflectance spectroscopy.

  3. Upper limit on a stochastic background of gravitational waves from seismic measurements in the range 0.05-1 Hz.

    Science.gov (United States)

    Coughlin, Michael; Harms, Jan

    2014-03-14

    In this Letter, we present an upper limit of ΩGWgravitational-wave (GW) background integrated over a year in the frequency range 0.05-1 Hz, which improves current upper limits from high-precision laboratory experiments by about 9 orders of magnitude. The limit is obtained using the response of Earth itself to GWs via a free-surface effect described more than 40 years ago by Dyson. The response was measured by a global network of broadband seismometers selected to maximize the sensitivity.

  4. Excited state absorption measurement in the 900-1250 nm wavelength range for bismuth-doped silicate fibers.

    Science.gov (United States)

    Yoo, Seongwoo; Kalita, Mridu P; Nilsson, Johan; Sahu, Jayanta

    2009-02-15

    The feasibility of direct laser diode pumping of Bi-doped fiber lasers at the wavelengths of 915 and 975 nm was examined by measuring excited state absorption in Bi-doped silicate fibers for the wavelength range of 900-1250 nm. When the Bi-doped fibers were pumped at 1047 nm a strong excited state absorption was found at 915 and 975 nm, whereas no significant excited state absorption was observed in the 1080 nm pumping band nor in the emission band, approximately 1160 nm, of Bi-doped fiber lasers.

  5. Validity of clinical outcome measures to evaluate ankle range of motion during the weight-bearing lunge test.

    Science.gov (United States)

    Hall, Emily A; Docherty, Carrie L

    2017-07-01

    To determine the concurrent validity of standard clinical outcome measures compared to laboratory outcome measure while performing the weight-bearing lunge test (WBLT). Cross-sectional study. Fifty participants performed the WBLT to determine dorsiflexion ROM using four different measurement techniques: dorsiflexion angle with digital inclinometer at 15cm distal to the tibial tuberosity (°), dorsiflexion angle with inclinometer at tibial tuberosity (°), maximum lunge distance (cm), and dorsiflexion angle using a 2D motion capture system (°). Outcome measures were recorded concurrently during each trial. To establish concurrent validity, Pearson product-moment correlation coefficients (r) were conducted, comparing each dependent variable to the 2D motion capture analysis (identified as the reference standard). A higher correlation indicates strong concurrent validity. There was a high correlation between each measurement technique and the reference standard. Specifically the correlation between the inclinometer placement at 15cm below the tibial tuberosity (44.9°±5.5°) and the motion capture angle (27.0°±6.0°) was r=0.76 (p=0.001), between the inclinometer placement at the tibial tuberosity angle (39.0°±4.6°) and the motion capture angle was r=0.71 (p=0.001), and between the distance from the wall clinical measure (10.3±3.0cm) to the motion capture angle was r=0.74 (p=0.001). This study determined that the clinical measures used during the WBLT have a high correlation with the reference standard for assessing dorsiflexion range of motion. Therefore, obtaining maximum lunge distance and inclinometer angles are both valid assessments during the weight-bearing lunge test. Copyright © 2016 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  6. Reliability of knee joint range of motion and circumference measurements after total knee arthroplasty: does tester experience matter?

    DEFF Research Database (Denmark)

    Jakobsen, Thomas Linding; Christensen, Malene; Christensen, Stine Sommer

    2010-01-01

    BACKGROUND AND PURPOSE: Two of the most utilized outcome measures to assess knee joint range of motion (ROM) and intra-articular effusion are goniometry and circumference, respectively. Neither goniometry nor circumference of the knee joint have been examined for both intra-tester and inter......-tester in patients with total knee arthroplasty (TKA). The purpose of this study was to determine the intra-tester and inter-tester reliability of active and passive knee joint ROM and circumference in patients with TKA when administered by physiotherapists (testers) with different clinical experience. METHOD......: The design was an intra-tester, inter-tester and intra-day reliability study. Nineteen outpatients (10 females) having received a TKA were examined by an inexperienced and an experienced physiotherapist. Following a standardized protocol, active and passive knee joint ROM and circumference measurements were...

  7. Educação gerencial para atuação em ambientes de negócios sustentáveis: desafios e tendências de uma escola de negócios brasileira.

    Directory of Open Access Journals (Sweden)

    Katia Cyrlene de Araujo Vasconcelos

    2013-08-01

    Full Text Available O objetivo deste artigo é descrever e analisar, por meio de um estudo de caso de natureza qualitativa, como o projeto pedagógico de um programa de educação gerencial viabiliza a formação de gestores para atuação em ambientes de negócios sustentáveis. Para isso, estabeleceu-se um debate sobre os temas negócios sustentáveis e educação gerencial no contexto de uma escola de negócios brasileira com atuação internacional. Considera-se que o ambiente de negócios passa por transformações que implicam repensar a relação entre o homem, a organização e o mundo, o paradigma econômico e a forma de produzir e de gerar valor não só para o presente, mas também para as gerações futuras. Em relação ao papel gerencial, assume-se que há uma transição em curso que extrapola as funções administrativas típicas, como planejamento, organização, liderança e controle, chegando ao campo da influência, da adaptação a diferentes contextos, da imprevisibilidade, do pensamento para além das cercas mentais e da convivência com os paradoxos. Os dados foram coletados via triangulação, ao articular a realização de entrevistas semiestruturadas com dez profissionais do corpo diretivo e técnico da escola, com análise documental e observação assistemática. As evidências apontam que há esforços da escola para viabilizar seus projetos pedagógicos com base em pressupostos de uma educação voltada para a sustentabilidade, ao disponibilizar um ambiente de aprendizagem experiencial, colaborativo, coletivo e interdisciplinar, e promover a educação de pessoas reflexivas, conscientes, autônomas, com visão ampliada e responsável por suas ações. Entretanto, a escola vive situações paradoxais ao atender às demandas de um mundo corporativo, que ainda insiste em práticas gerenciais que já não são mais suficientes para o modelo de negócios em ambientes sustentáveis, uma vez que o universo corporativo ainda vivencia a l

  8. A study on the measurement of wrist motion range using the iPhone 4 gyroscope application.

    Science.gov (United States)

    Kim, Tae Seob; Park, David Dae Hwan; Lee, Young Bae; Han, Dong Gil; Shim, Jeong Su; Lee, Young Jig; Kim, Peter Chan Woo

    2014-08-01

    Measuring the range of motion (ROM) of the wrist is an important physical examination conducted in the Department of Hand Surgery for the purpose of evaluation, diagnosis, prognosis, and treatment of patients. The most common method for performing this task is by using a universal goniometer. This study was performed using 52 healthy participants to compare wrist ROM measurement using a universal goniometer and the iPhone 4 Gyroscope application. Participants did not have previous wrist illnesses and their measured values for wrist motion were compared in each direction. Normal values for wrist ROM are 73 degrees of flexion, 71 degrees of extension, 19 degrees of radial deviation, 33 degrees of ulnar deviation, 140 degrees of supination, and 60 degrees of pronation.The average measurement values obtained using the goniometer were 74.2 (5.1) degrees for flexion, 71.1 (4.9) degrees for extension, 19.7 (3.0) degrees for radial deviation, 34.0 (3.7) degrees for ulnar deviation, 140.8 (5.6) degrees for supination, and 61.1 (4.7) degrees for pronation. The average measurement values obtained using the iPhone 4 Gyroscope application were 73.7 (5.5) degrees for flexion, 70.8 (5.1) degrees for extension, 19.5 (3.0) degrees for radial deviation, 33.7 (3.9) degrees for ulnar deviation, 140.4 (5.7) degrees for supination, and 60.8 (4.9) degrees for pronation. The differences between the measurement values by the Gyroscope application and average value were 0.7 degrees for flexion, -0.2 degrees for extension, 0.5 degrees for radial deviation, 0.7 degrees for ulnar deviation, 0.4 degrees for supination, and 0.8 degrees for pronation. The differences in average value were not statistically significant. The authors introduced a new method of measuring the range of wrist motion using the iPhone 4 Gyroscope application that is simpler to use and can be performed by the patient outside a clinical setting.

  9. Molecular Desorption of a NEG St 707 Irradiated at Room Temperature with Synchrotron Radiation of 194 eV Critical Photon Energy

    CERN Document Server

    Le Pimpec, F; Laurent, Jean Michel

    2002-01-01

    Photon stimulated molecular desorption from a NEG St 707 (SAES Getters$^{TM}$) surface after conditioning and after saturation with isotopic carbon monoxide, 13C18O, has been studied on a dedicated beam line at the EPA ring at CERN. The synchrotron radiation of 194 eV critical energy and with an average photon intensity of ~1 10**17 photons.s**-1 was impinging on the sample at perpendicular incidence. It is found that the desorption yields h molecules/photon) of the characteristic gases in an UHV system (hydrogen, methane, carbon monoxide and carbon dioxide) for a freshly activated NEG and for a NEG fully saturated with 13C18O are lower than that of 300 C baked stainless steel.

  10. A comparison of two stretching modalities on lower-limb range of motion measurements in recreational dancers.

    Science.gov (United States)

    Wyon, Matthew; Felton, Lee; Galloway, Shaun

    2009-10-01

    Most stretching techniques are designed to place a "stress" on the musculoskeletal unit that will increase its resting length and range of motion (ROM). Twenty-four adolescent dancers participated in a 6-week intervention program that compared low-intensity stretching (Microstretching) with moderate-intensity static stretching on active and passive ranges of motion. Microstretching is a new modality that reduces the possibility of the parasympathetic system being activated. Repeated measures analysis indicated changes in ROM over the intervention period (p active ROM than the static stretch group (p stretching increases the compliance of any given muscle and therefore increases the range of motion. One main finding of the present study was that throughout a 6-week training program very-low-intensity stretching had a greater positive effect on lower-limb ROM than moderate-intensity static stretching. The most interesting aspect of the study was the greater increase in active ROM compared to passive ROM by the Microstretching group. This suggests that adaptation has occurred within the muscle itself to a greater extent than in structures of the hip joint. Practical application for this technique suggests it is beneficial as a postexercise modality that potentially has a restorative component.

  11. Precise Measurement of the $\\bar{p}p$ Total Cross-Section in the ISR Energy Range

    CERN Multimedia

    2002-01-01

    The major aim of this experiment is the precise measurement of the antiproton-proton total cross-section in the ISR energy range, using the total-rate method. The proton-proton total cross-section is remeasured with the same method and the same apparatus, and a precision of 0.5\\% is expected for both cross-sections. The total-rate method consists in the simultaneous measurement of the total interaction rate and the ISR luminosity. This is done with a set of scintillation-counter hodoscopes covering over 99.99\\% of the solid angle, which are sensitive to over 95\\% of all interactions. In addition to these detectors, small-angle drift-tube hodoscopes are used to measure the differential elastic cross-section as a function of the momentum transfert t. The total cross-section can be measured independently by extrapolating this differential cross-section to the forward direction and invoking the optical theorem. A study of the general features of charged-particle production is performed using finely divided scinti...

  12. Optimal Sensor Placement for Multiple Target Positioning with Range-Only Measurements in Two-Dimensional Scenarios

    Directory of Open Access Journals (Sweden)

    Joaquin Aranda

    2013-08-01

    Full Text Available The problem of determining the optimal geometric configuration of a sensor network that will maximize the range-related information available for multiple target positioning is of key importance in a multitude of application scenarios. In this paper, a set of sensors that measures the distances between the targets and each of the receivers is considered, assuming that the range measurements are corrupted by white Gaussian noise, in order to search for the formation that maximizes the accuracy of the target estimates. Using tools from estimation theory and convex optimization, the problem is converted into that of maximizing, by proper choice of the sensor positions, a convex combination of the logarithms of the determinants of the Fisher Information Matrices corresponding to each of the targets in order to determine the sensor configuration that yields the minimum possible covariance of any unbiased target estimator. Analytical and numerical solutions are well defined and it is shown that the optimal configuration of the sensors depends explicitly on the constraints imposed on the sensor configuration, the target positions, and the probabilistic distributions that define the prior uncertainty in each of the target positions. Simulation examples illustrate the key results derived.

  13. Multispectral measurement of contrast in tissue-mimicking phantoms in near-infrared spectral range of 650 to 1600 nm.

    Science.gov (United States)

    Salo, Daniel; Zhang, Hairong; Kim, David M; Berezin, Mikhail Y

    2014-08-01

    In order to identify the optimal imaging conditions for the highest spatial contrast in biological tissue, we explored the properties of a tissue-mimicking phantom as a function of the wavelengths in a broad range of near-infrared spectra (650 to 1600 nm). Our customized multispectral hardware, which featured a scanning transmission microscope and imaging spectrographs equipped with silicon and InGaAs charge-coupled diode array detectors, allowed for direct comparison of the Michelson contrast obtained from a phantom composed of a honeycomb grid, Intralipid, and India ink. The measured contrast depended on the size of the grid, luminance, and the wavelength of measurements. We demonstrated that at low thickness of the phantom, a reasonable contrast of the objects can be achieved at any wavelength between 700 and 1400 nm and between 1500 and 1600 nm. At larger thicknesses, such contrast can be achieved mostly between 1200 and 1350 nm. These results suggest that distinguishing biological features in deep tissue and developing contrast agents for in vivo may benefit from imaging in this spectral range.

  14. Evaluation of EIT systems and algorithms for handling full void fraction range in two-phase flow measurement

    Science.gov (United States)

    Jia, Jiabin; Wang, Mi; Faraj, Yousef

    2015-01-01

    In the aqueous-based two-phase flow, if the void fraction of dispersed phase exceeds 0.25, conventional electrical impedance tomography (EIT) produces a considerable error due to the linear approximation of the sensitivity back-projection (SBP) method, which limits the EIT’s wider application in the process industry. In this paper, an EIT sensing system which is able to handle full void fraction range in two-phase flow is reported. This EIT system employs a voltage source, conducts true mutual impedance measurement and reconstructs an online image with the modified sensitivity back-projection (MSBP) algorithm. The capability of the Maxwell relationship to convey full void fraction is investigated. The limitation of the linear sensitivity back-projection method is analysed. The MSBP algorithm is used to derive relative conductivity change in the evaluation. A series of static and dynamic experiments demonstrating the mean void fraction obtained using this EIT system has a good agreement with reference void fractions over the range from 0 to 1. The combination of the new EIT system and MSBP algorithm would significantly extend the applications of EIT in industrial process measurement.

  15. Fatores relevantes de competitividade no negócio de consultoria de tecnologia da informação

    Directory of Open Access Journals (Sweden)

    Antonio Carlos Calicchio

    Full Text Available Resumo Este artigo identifica como as empresas de consultoria de tecnologia da informação (TI utilizam seus recursos e capacidades na busca pela vantagem competitiva, sob a abordagem da Visão Baseada em Recursos (VBR. A pesquisa foi do tipo exploratório e de natureza descritiva, tendo-se adotado o método qualitativo, com entrevistas em profundidade orientadas por um roteiro padrão com perguntas abertas. Foram entrevistados sete executivos da alta gestão de empresas de consultoria de TI classificadas entre as Top 10 deste segmento. Para a análise e interpretação dos dados, foi aplicada a Análise de Conteúdo, com o apoio de uma planilha para gerar as categorias da análise. Como resultado, foi identificado que as empresas que participaram da pesquisa utilizam-se do conhecimento dos seus recursos humanos e do relacionamento com os clientes, como componentes cruciais de suas estratégias de negócios. Esses recursos e capacidades são estrategicamente utilizados, aproveitando o vínculo estabelecido com o cliente na busca de novas oportunidades de negócios, de maneira a criar uma barreira às ameaças de novos entrantes.

  16. Fatores críticos na implementação de estratégias de negócios

    OpenAIRE

    Yazaki, Paulo Akihumi

    2010-01-01

    Identifica-se os fatores críticos na implementação de estratégias de negócios, as dificuldades e as barreiras quando da formulação da estratégia, na gestão de pessoas e no desenho dos processos para se alcançar as metas e os resultados planejados. Uma pesquisa de campo realizada dentro de um ambiente real de negócios permitiu identificar e avaliar a pertinência dos fatores críticos de implementação de estratégia.

  17. A influência das arenas esportivas na criação e sobrevivência de micro e pequenos negócios

    OpenAIRE

    Orlando, Silvia Simoni

    2015-01-01

    O futebol é um esporte reconhecido no Brasil como fenômeno cultural e mobilizador da economia por influenciar e movimentar diversos segmentos de negócio. Tendo em vista essa característica do esporte, este estudo teve por objetivo identificar a influência das arenas esportivas dos principais clubes de futebol do estado de São Paulo, na criação e sobrevivência de micro e pequenos negócios empreendedores em seu entorno. As arenas pesquisadas foram: Arena Corinthians, Allianz Park, Estádio Cícer...

  18. Radiological Assessment of the Sacrofemoral Angle: A Novel Method to Measure the Range of Hip Joint Flexion.

    Science.gov (United States)

    Wei, Xian-Zhao; Xu, Xi-Ming; Wang, Fei; Li, Ming; Wang, Zi-Min

    2015-09-05

    A quantitative and accurate measurement of the range of hip joint flexion (RHF) is necessarily required in the evaluation of disordered or artificial hip joint function. This study aimed to assess a novel method to measure RHF more accurately and objectively. Lateral radiographs were taken of 31 supine men with hip joints extended or flexed. Relevant angles were measured directly from the radiographs. The change in the sacrofemoral angle (SFA) (the angle formed between the axis of the femur and the line tangent to the upper endplate of S1) from hip joint extension to hip joint flexion, was proposed as the RHF. The validity of this method was assessed via concomitant measurements of changes in the femur-horizontal angle (between the axis of the femur and the horizontal line) and the sacrum-horizontal angle (SHA) (between the line tangent to the upper endplate of S1 and the horizontal line), the difference of which should equal the change in the SFA. The mean change in the SFA was 112.5 ± 7.4°, and was independent of participant age, height, weight, or body mass index. The mean changes in the femur-horizontal and SHAs were 123.0 ± 6.4° and 11.4 ± 3.0°, respectively. This confirmed that the change of SFA between hip joint extension and hip joint flexion was equal to the difference between the changes in the femur-horizontal and SHAs. Using the SFA, to evaluate RHF could prevent compromised measurements due to the movements of pelvis and lumbar spine during hip flexion, and is, therefore, a more accurate and objective method with reasonable reliability and validity.

  19. Reliability of knee joint range of motion and circumference measurements after total knee arthroplasty: does tester experience matter?

    Science.gov (United States)

    Jakobsen, Thomas Linding; Christensen, Malene; Christensen, Stine Sommer; Olsen, Marie; Bandholm, Thomas

    2010-09-01

    Two of the most utilized outcome measures to assess knee joint range of motion (ROM) and intra-articular effusion are goniometry and circumference, respectively. Neither goniometry nor circumference of the knee joint have been examined for both intra-tester and inter-tester in patients with total knee arthroplasty (TKA). The purpose of this study was to determine the intra-tester and inter-tester reliability of active and passive knee joint ROM and circumference in patients with TKA when administered by physiotherapists (testers) with different clinical experience. The design was an intra-tester, inter-tester and intra-day reliability study. Nineteen outpatients (10 females) having received a TKA were examined by an inexperienced and an experienced physiotherapist. Following a standardized protocol, active and passive knee joint ROM and circumference measurements were obtained using a universal goniometer and a tape measure, respectively. To establish reliability, intraclass correlation coefficients (ICC(2,1)) and smallest real difference (SRD) were calculated. The knee joint ROM and circumference measurements were generally reliable (ICC > 0.8) within and between physiotherapists (except passive knee extension). Changes in knee joint ROM of more than 6.6 degrees and 10 degrees (except active knee flexion) and knee joint circumference of more than 1.0 cm and 1.63 cm represent a real clinical improvement (SRD) or deterioration for a single individual within and between physiotherapists, respectively. Generally, the experienced tester recorded larger knee joint ROM and lower circumference values than that of the inexperienced tester. In clinical practice, we suggest that repeated knee goniometric and circumferential measurements should be recorded by the same physiotherapist in individual patients with TKA. Tester experience appears not to influence the degree of reliability. (c) 2009 John Wiley & Sons, Ltd.

  20. Wide range instantaneous temperature measurements of convective fluid flows by using a schlieren system based in color images

    Science.gov (United States)

    Martínez-González, A.; Moreno-Hernández, D.; Monzón-Hernández, D.; León-Rodríguez, M.

    2017-06-01

    In the schlieren method, the deflection of light by the presence of an inhomogeneous medium is proportional to the gradient of its refractive index. Such deflection, in a schlieren system, is represented by light intensity variations on the observation plane. Then, for a digital camera, the intensity level registered by each pixel depends mainly on the variation of the medium refractive index and the status of the digital camera settings. Therefore, in this study, we regulate the intensity value of each pixel by controlling the camera settings such as exposure time, gamma and gain values in order to calibrate the image obtained to the actual temperature values of a particular medium. In our approach, we use a color digital camera. The images obtained with a color digital camera can be separated on three different color-channels. Each channel corresponds to red, green, and blue color, moreover, each one has its own sensitivity. The differences in sensitivity allow us to obtain a range of temperature values for each color channel. Thus, high, medium and low sensitivity correspond to green, blue, and red color channel respectively. Therefore, by adding up the temperature contribution of each color channel we obtain a wide range of temperature values. Hence, the basic idea in our approach to measure temperature, using a schlieren system, is to relate the intensity level of each pixel in a schlieren image to the corresponding knife-edge position measured at the exit focal plane of the system. Our approach was applied to the measurement of instantaneous temperature fields of the air convection caused by a heated rectangular metal plate and a candle flame. We found that for the metal plate temperature measurements only the green and blue color-channels were required to sense the entire phenomena. On the other hand, for the candle case, the three color-channels were needed to obtain a complete measurement of temperature. In our study, the candle temperature was took as

  1. Measurement of changes in glacier extent in the Rimo glacier, a sub-range of the Karakoram Range, determined from Landsat imagery

    Directory of Open Access Journals (Sweden)

    Prashant Kumar

    2014-01-01

    Full Text Available Accurate estimation of the spatiotemporal surface dynamics is very important for natural resource planning. This paper discusses a novel approach for the study of the surface patterns of a particular glacier Rimo located at 35°21′21″N77°22′05″E, about 20 km northeast of the snout of Siachen. Change detection in multiple images of the same location taken at different time intervals are of widely circulated use due to a large number of applications in various disciplines such as climate change, remote sensing and so on. The proposed technique uses image processing to derive regression models of selected glacier segments, these models are then used to measure area under the curve to estimate the surface area changes of the glacier. The surface area changes thus obtained have also been validated by standard method of pixel counting. With the rise in the global warming, the net change in the surface area of the concerned glacier is estimated using statistical analysis from 1998 to 2011. The results obtained show a fair degree of accuracy as compared to the standard method of pixel counting. We also discuss important pre-processing methods used in extracting the final concerned region of interest from a large satellite imagery of fairly average resolution.

  2. Normal ranges of right ventricular systolic and diastolic strain measures in children: a systematic review and meta-analysis.

    Science.gov (United States)

    Levy, Philip T; Sanchez Mejia, Aura A; Machefsky, Aliza; Fowler, Susan; Holland, Mark R; Singh, Gautam K

    2014-05-01

    Establishment of the range of normal values and associated variations of two-dimensional (2D) speckle-tracking echocardiography (STE)-derived right ventricular (RV) strain is a prerequisite for its routine clinical application in children. The objectives of this study were to perform a meta-analysis of normal ranges of RV longitudinal strain measurements derived by 2D STE in children and to identify confounders that may contribute to differences in reported measures. A systematic review was conducted in PubMed, Embase, Scopus, the Cochrane Central Register of Controlled Trials, and ClinicalTrials.gov. Search hedges were created to cover the concepts of pediatrics, STE, and the right heart ventricle. Two investigators independently identified and included studies if they reported the 2D STE-derived RV strain measure RV peak global longitudinal strain, peak global longitudinal systolic strain rate, peak global longitudinal early diastolic strain rate, peak global longitudinal late diastolic strain rate, or segmental longitudinal strain at the apical, middle, and basal ventricular levels in healthy children. Quality and reporting of the studies were assessed. The weighted mean was estimated using random effects with 95% confidence intervals (CIs), heterogeneity was assessed using Cochran's Q statistic and the inconsistency index (I(2)), and publication bias was evaluated using funnel plots and Egger's test. Effects of demographic, clinical, equipment, and software variables were assessed in a metaregression. The search identified 226 children from 10 studies. The reported normal mean values of peak global longitudinal strain among the studies varied from -20.80% to -34.10% (mean, -29.03%; 95% CI, -31.52% to -26.54%), peak global longitudinal systolic strain rate varied from -1.30 to -2.40 sec(-1) (mean, -1.88 sec(-1); 95% CI, -2.10 to -1.59 sec(-1)), peak global longitudinal early diastolic strain rate ranged from 1.7 to 2.69 sec(-1) (mean, 2.34 sec(-1); 95% CI, 2

  3. Gerenciamento de processos de negócio em biblioteca pública

    Directory of Open Access Journals (Sweden)

    Thatiane Aparecida de Lima Giviani

    2015-09-01

    Full Text Available Este trabalho traz um estudo da Divisão de Tratamento Técnico da Informação do Sistema Integrado de Bibliotecas do Município de São Carlos (SIBI/SC. O objetivo é mapear os processos do setor de processamento técnico do material bibliográfico do sistema, desde sua aquisição até sua disponibilização para o usuário. Para isto, fez uso da modelagem de processos de negócios.  A metodologia empregada foi a pesquisa-ação e bibliográfica. Como resultado do mapeamento foram identificados pontos críticos e propostas soluções, visando a melhoria dos serviços prestados no Sistema Integrado de Bibliotecas do Município de São Carlos. Abstract: This paper presents a study from Division of Information Technical Treatment belonging to the Library Integrated System of São Carlos City (SIBI-SC. Technical Treatment is responsible for receiving works, classification and indexing, tipping, availability on the collection and inventory of all library materials of system integrators libraries. The aim is to map the processes from division of technical treatment of the system, since its acquisition to its availability to the user. For such, the study applied the business process modeling approach. The methodological procedures used in the research include action research and bibliographic research. The result of mapping identified critical points for which solutions were proposed, aiming to improve the services provided by the system. Keywords: Library. BPM. Business processes management. Public management. Process integration. Process mapping. Resumen: En este trabajo se presenta un estudio de la División de Tratamiento Técnico de Información del Sistema Integrado de Biblioteca en São Carlos / SP (SIBI-SC. Tratamiento Técnico se encarga de recibir las obras, la clasificación y la indexación, la propina, disponible en los activos e inventario de todos los materiales de la biblioteca de las bibliotecas integradores de sistemas. El

  4. A new faces scale in pain measurement: a test of bias from current mood, trait affectivity, and scale range.

    Science.gov (United States)

    Elfering, Achim; Grebner, Simone

    2012-01-01

    Faces pain rating scales used among children have been criticized to confound affective states with pain when smiling faces are included. This experimental study is an attempt to examine the possible confounding of affective states with pain when smiling faces are used as part of a faces scale. The meaning of the faces was tested to depend on current mood, current pain, trait affectivity, and inclusion versus exclusion of smiling faces. Sixty-four participants made 6,720 two-categorical pain judgments on faces with different mouth curvature. In multilevel regression analysis, current level of pain and negative trait affectivity biased faces' meaning only when the smiling faces were excluded from the scale. In adults, the new full range faces pain scale including a midpoint neutral face and smiling faces was more robust than the restricted scale. The faces scale that was tested in this study is not applicable for patient measurement but it is an interesting tool for psychological research.

  5. Measurement of performance of thermoacoustic heat pump in a -3 to 160 °C temperature range

    Science.gov (United States)

    Kikuchi, Ryo; Tsuda, Kenichiro; Bassem, Mohamed Mehdi; Ueda, Yuki

    2015-11-01

    A thermoacoustic heat pump was constructed and tested. It was composed of a looped tube, a straight tube, and a regenerator. The looped tube contained the regenerator and was connected to the straight tube. The tubes were filled with nitrogen. When an acoustic wave was input to the tubes, a temperature difference formed along the regenerator. Our experiments showed that this heat pump could work as both a cooler and a heater. This heat pump achieved -39 °C as a cooler and 270 °C as a heater. Using antifreeze liquid and oil as heat media, the cooling and heating performance of the heat pump was measured within the temperature range from -3 to 160 °C.

  6. Blackbody Sources for the Range 100 K to 3500 K for Precision Measurements in Radiometry and Radiation Thermometry

    Science.gov (United States)

    Sapritsky, V. I.; Khlevnoy, B. B.; Khromchenko, V. B.; Ogarev, S. A.; Morozova, S. P.; Lisiansky, B. E.; Samoylov, M. L.; Shapoval, V. I.; Sudarev, K. A.

    2003-09-01

    The paper presents a detailed review of precision blackbodies that are low-, medium-, and high-temperature range sources developed at VNIIOFI during the past 30 years. Low-temperature blackbodies were developed for calibration facilities of spaceborne instruments. Medium-temperature blackbodies are used for radiance temperature and IR radiometric measurements. The high-temperature pyrolitic graphite blackbodies BB3200 and BB3500 were developed for world-leading metrology centers as NIST (USA), PTB (Germany), NPL (Great Britain), VNIIOFI (Russia), CNAM (France) and others for the realization and dissemination of radiometric and radiation temperature scales. The latest modification of the high-temperature blackbody BB3500MP, the large-aperture version (with an opening of up to 16 mm) of the famous BB3500, suitable for holding large fixed-point cells with high-temperature TiC-C and ZrC-C eutectics, is under development.

  7. Application of the Two-Step Filter to Process Ranging Measurements for Relative Navigation in an Elliptical Orbit

    Science.gov (United States)

    Garrison, James L.; Axelrad, Penina

    1997-01-01

    This estimator breaks a nonlinear estimation problem into a set of over determined 'first step' states which are linear in the observations and 'second step' states which are ultimately the states of interest. Linear estimation methods are applied to filter the observations and produce the optimal first step state estimate. The 'second step' states are obtained through iterative nonlinear parameter estimation considering the first step states as observations. It has been shown that this process exactly minimizes the least squares cost function for static problems and provides a better solution than the iterated extended Kalman filter (EKF) for dynamic problems. The two step filter is applied in this paper to process range and range rate measurements between the two spacecraft. Details of the application of the two step estimator to this problem will be given, highlighting the use of a test for ill-conditioned covariance estimates that can result from the first order covariance propagation. A comparison will be made between the performance of the two step filter and the IEKF.

  8. Measurements and Monte Carlo calculations with the extended-range Bonner sphere spectrometer at high-energy mixed fields

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00406842; Bay, Aurelio; Silari, Marco; Aroua, Abbas

    The use of spectrometry to provide information for neutron radiation protection has become an increasingly important activity over recent years. The need for spectral data arises because neither area survey instruments nor personal dosimeters give the correct dose equivalent results at all neutron energies. It is important therefore to know the spectra of the fields in which these devices are used. One of the systems most commonly employed in neutron spectrometry and dosimetry is the Bonner Sphere Spectrometers (BSS). The extended- range BSS that was used for this work, consists of 7 spheres with an overall response to neutrons up to 2 GeV. A 3He detector is used as a thermal counter in the centre of each sphere. In the context of this thesis the BSS was calibrated in monoenergetic neutron fields at low and intermediate energies. It was also used for measurements in several high energy mixed fields. These measurements have led to the calculation of neutron yields and spectral fluences from unshielded targets....

  9. Measurement and Modeling of Short and Medium Range Order in Amorphous Ta2O5 Thin Films

    Science.gov (United States)

    Shyam, Badri; Stone, Kevin H.; Bassiri, Riccardo; Fejer, Martin M.; Toney, Michael F.; Mehta, Apurva

    2016-08-01

    Amorphous films and coatings are rapidly growing in importance. Yet, there is a dearth of high-quality structural data on sub-micron films. Not understanding how these materials assemble at atomic scale limits fundamental insights needed to improve their performance. Here, we use grazing-incidence x-ray total scattering measurements to examine the atomic structure of the top 50-100 nm of Ta2O5 films; mirror coatings that show high promise to significantly improve the sensitivity of the next generation of gravitational-wave detectors. Our measurements show noticeable changes well into medium range, not only between crystalline and amorphous, but also between as-deposited, annealed and doped amorphous films. It is a further challenge to quickly translate the structural information into insights into mechanisms of packing and disorder. Here, we illustrate a modeling approach that allows translation of observed structural features to a physically intuitive packing of a primary structural unit based on a kinked Ta-O-Ta backbone. Our modeling illustrates how Ta-O-Ta units link to form longer 1D chains and even 2D ribbons, and how doping and annealing influences formation of 2D order. We also find that all the amorphousTa2O5 films studied in here are not just poorly crystalline but appear to lack true 3D order.

  10. Airborne Light Detection and Ranging (LiDAR for Individual Tree Stem Location, Height, and Biomass Measurements

    Directory of Open Access Journals (Sweden)

    Michael G. Wing

    2011-11-01

    Full Text Available Light Detection and Ranging (LiDAR remote sensing has demonstrated potential in measuring forest biomass. We assessed the ability of LiDAR to accurately estimate forest total above ground biomass (TAGB on an individual stem basis in a conifer forest in the US Pacific Northwest region using three different computer software programs and compared results to field measurements. Software programs included FUSION, TreeVaW, and watershed segmentation. To assess the accuracy of LiDAR TAGB estimation, stem counts and heights were analyzed. Differences between actual tree locations and LiDAR-derived tree locations using FUSION, TreeVaW, and watershed segmentation were 2.05 m (SD 1.67, 2.19 m (SD 1.83, and 2.31 m (SD 1.94, respectively, in forested plots. Tree height differences from field measured heights for FUSION, TreeVaW, and watershed segmentation were −0.09 m (SD 2.43, 0.28 m (SD 1.86, and 0.22 m (2.45 in forested plots; and 0.56 m (SD 1.07 m, 0.28 m (SD 1.69 m, and 1.17 m (SD 0.68 m, respectively, in a plot containing young conifers. The TAGB comparisons included feature totals per plot, mean biomass per feature by plot, and total biomass by plot for each extraction method. Overall, LiDAR TAGB estimations resulted in FUSION and TreeVaW underestimating by 25 and 31% respectively, and watershed segmentation overestimating by approximately 10%. LiDAR TAGB underestimation occurred in 66% and overestimation occurred in 34% of the plot comparisons.

  11. Wide Dynamic Range Multiband Infrared Radiometer for In-Fire Measurements of Wildland Fire Radiant Flux Density

    Science.gov (United States)

    Kremens, R.; Dickinson, M. B.; Hardy, C.; Skowronski, N.; Ellicott, E. A.; Schroeder, W.

    2016-12-01

    We have developed a wide dynamic range (24-bit) data acquisition system for collection of radiant flux density (FRFD) data from wildland fires. The data collection subsystem was designed as an Arduino `shield' and incorporates a 24-bit analog-to-digital converter, precision voltage reference, real time clock, microSD card interface, audible annuciator and interface for various digital communication interfaces (RS232, I2C, SPI, etc.). The complete radiometer system consists of our custom-designed `shield', a commercially available Arduino MEGA computer circuit board and a thermopile sensor -amplifier daughter board. Software design and development is greatly assisted by the availability of a library of public-domain, user-implemented software. The daughter board houses a 5-band radiometer using thermopiles designed for this experiment (Dexter Research Corp., Dexter, MI) to allow determination of the total FRFD from the fire (using a wide band thermopile with a KRS-5 window, 0.1 - 30 um), the FRFD as would be received by an orbital asset like MODIS (3.95 um center wavelength (CWL) and 10.95 CWL, corresponding to MODIS bands 21/22 and 31, respectively) and wider bandpass (0.1-5.5 um and 8-14 um) corresponding to the FRFD recorded by `MWIR' and `LWIR' imaging systems. We required a very wide dynamic range system in order to be able to record the flux density from `cold' ground before the fire, through the `hot' flaming combustion stage, to the `cool' phase after passage of the fire front. The recording dynamic range required (with reasonable resolution at the lowest temperatures) is on the order of 106, which is not currently available in commercial instrumentation at a price point, size or feature set that is suitable for wildland fire investigations. The entire unit, along with rechargeable battery power supply is housed in a fireproof aluminum chassis box, which is then mounted on a mast at a height of 5 - 7 m above the fireground floor. We will report initial

  12. Lógica de empreendedorismo no Ensino Superior: empreendedorismo de negócio e empreendedorismo social

    OpenAIRE

    Lopes, Rui Pedro; Mesquita, Cristina

    2015-01-01

    Os recentes Relatório da União Europeia (2012) e da OECDE (2012) sobre o ensino superior têm acentuado a importância da dinamização da cultura empreendedora, enunciado mesmo os impactos que esta tem ao nível da construção de competências- chave, da inserção no mercado de trabalho e do desenvolvimento da economia e da sociedade. Tem surgido, neste âmbito, uma diversidade de estudos que fazem emergir duas correntes de empreendedorismo: o social e o de negócios. A interação das IES com parcei...

  13. Sviluppo e validazione di un antigene-capture ELISA basato su anticorpi monoclonali specifici per Listeria monocytogenes negli alimenti

    Directory of Open Access Journals (Sweden)

    Rossella Lelli

    2011-09-01

    Full Text Available È stato standardizzato e validato un dosaggio immunoenzimatico capture ELISA per l’identificazione di Listeria monocytogenes negli alimenti. Il dosaggio è stato messo a punto analizzando campioni di prodotti carnei, ittici e lattiero-caseari, pasta di semola e di farina di grano. Il metodo è risultato specifico al 100% per Listeria spp., con limite di rivelazione di 6,6 × 10(3 cfu/ml. Il metodo L. monocytogenes capture ELISA è stato confrontato con il metodo ufficiale ISO 11290-1:1996 per l’isolamento e l’identificazione di L. monocytogenes in matrici alimentari ottenendo un indice di concordanza significativo. Il dosaggio è stato validato in base alle indicazioni della norma ISO 16140:2003 relativamente ai metodi di analisi qualitativi. Il dosaggio è risultato accurato, specifico, sensibile, selettivo, riproducibile e rapido da eseguire, consentendo nello screening degli alimenti la riduzione di tempi e costi dell’indagine microbiologica.

  14. Evaluation of long-range transport potential of selected brominated flame retardants with measured 1-octanol-air partition coefficients

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hyun Jeong; Kwon, Jung Hwan [Div. of Environmental Science and Ecological Engineering, Korea University, Seoul (Korea, Republic of)

    2016-10-15

    Various alternative flame retardants are used in many countries since polybrominated diphenyl ethers (PBDEs) were classified as persistent organic pollutants (POPs). However, difficulties in the evaluation of the long-range transport potential (LRTP) of the alternatives are related to the lack of information on their physicochemical properties, which govern their environmental fates and transport. Based on the simulation of LRTP using OECD P{sub OV} and LRTP Screening Tool, five alternative brominated flame retardants (BFRs) (hexabromobenzene [HBB], 2,3,4,5,6-pentabromotoluene [PBT], 2,3,4,5,6-pentabromoethylbenzene [PBEB], 2-ethylhexyl 2,3,4,5-tetrabromobenzoate [TBB], and 1,2,4,5-tetrabromo-3,6-dimethylbenzene [TBX]), and 3 PBDEs (BDE-28, BDE-47, and BDE-99) were chosen to perform a refined assessment. This was done using an experimentally measured 1-octanol–air partition coefficient (K{sub OA}) for the calculation of the air–water partition coefficient (K{sub AW}) required for the model. The four selected alternative BFRs (HBB, PBT, PBEB, TBX) have K{sub OA} values close to the in silico estimation used in the screening evaluation. On the other hand, the measured K{sub OA} value for TBB was two orders of magnitude lower than the estimated value used in the screening simulation. The refined simulation showed that characteristic travel distance (CTD) and transfer efficiency (TE) for HBB, PBT, PBEB, and TBX were greater than those for BDE-28, whereas CTD and TE for TBB were lower than those for BDE-28. This suggested that TBB has a lower LRTP than BDE-28, considering the refined partition coefficients.

  15. Gerando Modelo de Negócio: a pré-incubação como ambiente experimental

    Directory of Open Access Journals (Sweden)

    Anderson Paiva Cruz

    2016-04-01

    Full Text Available Este estudo visa contribuir para a construção de um modelo de monitoramento e avaliação que possibilite um melhor acompanhamento das empresas na fase de pré-incubação em uma incubadora de base tecnológica da Universidade Federal do Rio Grande do Norte (UFRN. O modelo de monitoramento e avaliação foi estruturado de acordo com o programa definido para a pré-incubação da incubadora. Na etapa de pré-incubação a incubadora tem a função de apoiar empreendedores a transformarem ideias inovadoras em negócios rentáveis e, para isso, oferece cursos e mentorias sobre Business Model Generation (BMG; Design Thinking Startup Enxuta; Estratégia do Oceano Azul; Métricas e Indicadores; e Pitch. A forma de acompanhamento dos empreendedores concilia os conceitos apresentados nos módulos do curso com as etapas de construção do BMG, desenvolvimento do protótipo e validação do negócio proposto pelos empreendedores. Metodologicamente, trata-se de uma pesquisa exploratória, com abordagem qualitativa, sendo utilizada a Pesquisa-ação para o modelo de acompanhamento das empresas e definição dos módulos do curso.A definição de um modelo padrão para acompanhamento e avaliação das empresas pré-incubadas permitiu um acompanhamento mais preciso do estágio de desenvolvimento da empresa e possibilitou que a incubadora pudesse cumprir seu papel de forma mais eficiente.

  16. Systemic immune suppression in glioblastoma: the interplay between CD14+HLA-DRlo/neg monocytes, tumor factors, and dexamethasone.

    Science.gov (United States)

    Gustafson, Michael P; Lin, Yi; New, Kent C; Bulur, Peggy A; O'Neill, Brian Patrick; Gastineau, Dennis A; Dietz, Allan B

    2010-07-01

    Patients with glioblastoma (GBM) exhibit profound systemic immune defects that affect the success of conventional and immune-based treatments. A better understanding of the contribution of the tumor and/or therapy on systemic immune suppression is necessary for improved therapies, to monitor negative effects of novel treatments, to improve patient outcomes, and to increase understanding of this complex system. To characterize the immune profile of GBM patients, we phenotyped peripheral blood and compared these to normal donors. In doing so, we identified changes in systemic immunity associated with both the tumor and dexamethasone treated tumor bearing patients. In particular, dexamethasone exacerbated tumor associated lymphopenia primarily in the T cell compartment. We have also identified unique tumor and dexamethasone dependent altered monocyte phenotypes. The major population of altered monocytes (CD14(+)HLA-DR(lo/neg)) had a phenotype distinct from classical myeloid suppressor cells. These cells inhibited T cell proliferation, were unable to fully differentiate into mature dendritic cells, were associated with dexamethasone-mediated changes in CCL2 levels, and could be re-created in vitro using tumor supernatants. We provide evidence that tumors express high levels of CCL2, can contain high numbers of CD14(+) cells, that tumor supernatants can transform CD14(+)HLA-DR(+) cells into CD14(+)HLA-DR(lo/neg) immune suppressors, and that dexamethasone reduces CCL2 in vitro and is correlated with reduction of CCL2 in vivo. Consequently, we have developed a model for tumor mediated systemic immune suppression via recruitment and transformation of CD14(+) cells.

  17. Evaluation of Spatial Resolution for Heavy Ion CT System Based on the Measurement of Residual Range Distribution With HIMAC

    Science.gov (United States)

    Muraishi, H.; Nishimura, K.; Abe, S.; Satoh, H.; Hara, S.; Hara, H.; Takahashi, Y.; Mogaki, T.; Kawai, R.; Yokoyama, K.; Yasuda, N.; Tomida, T.; Ohno, Y.; Kanai, T.

    2009-10-01

    We report experimental results from a heavy ion CT system based on the measurement of residual range distribution using an X-ray intensifying screen and a charged coupled device (CCD) camera system. This technique was first investigated by Zygmanski (2000) for proton beams, and they reported that the spatial resolution was significantly degraded by multiple Coulomb scattering (MCS) effects in the irradiated medium. Experiments were done on the spatial resolution phantom by using helium and carbon beams accelerated up to 120 MeV/u and 230 MeV/u by the Heavy Ion Medical Accelerator in Chiba (HIMAC), installed in the National Institute of Radiological Sciences (NIRS) in Japan, using a high performance intensified CCD (ICCD) camera. We show that the MCS blurring effect can be significantly reduced in the reconstructed image by using a carbon beam with this technique. Our results suggest that heavier particles such as carbon would be more useful if this technique is envisioned as a clinical tool to obtain data that would aid proton and/or heavy ion treatment planning.

  18. Uncertainties in forces extracted from non-contact atomic force microscopy measurements by fitting of long-range background forces

    Directory of Open Access Journals (Sweden)

    Adam Sweetman

    2014-04-01

    Full Text Available In principle, non-contact atomic force microscopy (NC-AFM now readily allows for the measurement of forces with sub-nanonewton precision on the atomic scale. In practice, however, the extraction of the often desired ‘short-range’ force from the experimental observable (frequency shift is often far from trivial. In most cases there is a significant contribution to the total tip–sample force due to non-site-specific van der Waals and electrostatic forces. Typically, the contribution from these forces must be removed before the results of the experiment can be successfully interpreted, often by comparison to density functional theory calculations. In this paper we compare the ‘on-minus-off’ method for extracting site-specific forces to a commonly used extrapolation method modelling the long-range forces using a simple power law. By examining the behaviour of the fitting method in the case of two radically different interaction potentials we show that significant uncertainties in the final extracted forces may result from use of the extrapolation method.

  19. Ozone sonde measurements aboard long-range boundary-layer pressurized balloons over the western Mediterranean basin

    Science.gov (United States)

    Gheusi, François; Barret, Brice; Verdier, Nicolas; Dulac, François; Durand, Pierre; Jambert, Corinne

    ChArMEx (http://charmex.lsce.ipsl.fr), including TRAQA in 2012 (launch base at Martigues, France) and ADRIMED (launch base at Sant Lluís, Minorca Island, Spain) and SAFMED (launch base at Levant Island off Hyères, France) in 2013. Complementary radiosoundings -- including ozone -- were also launched from these sites. BLPB drifting altitudes were in the range 0.25-3.2 km. The longest flight lasted more than 32 hours and covered more than 1000 km between Minorca and the limit of the authorized area south of Malta. Those quasi-Lagrangian measurements allow an evaluation of the ozone production/destruction rate as a function of the solar radiation (also measured onboard, as well as standard weather variables) that will be helpful to test chemistry-transport models.

  20. A low-power tool for measuring acceleration, pressure, and temperature (APT) with wide dynamic range and bandwidth

    Science.gov (United States)

    Heesemann, Martin; Davis, Earl E.; Paros, Jerome; Johnson, Greg; Meldrum, Robert; Scherwath, Martin; Mihaly, Steven

    2017-04-01

    We present a new tool that facilitates the study of inter-related geodetic, geodynamic, seismic, and oceanographic phenomena. It incorporates a temperature compensated tri-axial accelerometer developed by Quartz Seismic Sensors, Inc., a pressure sensor built by Paroscientific Inc., and a low-power, high-precision frequency counter developed by Bennest Enterprises Ltd. and built by RBR, Ltd. The sensors are housed in a 7 cm o.d. titanium pressure case designed for use to full ocean depths (withstands more than 20 km of water pressure). Sampling intervals are programmable from 0.08 s to 1 hr; standard memory can store up to 130 million samples; total power consumption is roughly 115 mW when operating continuously and proportionately lower when operating intermittently (e.g., 2 mW average at 1 sample per min). Serial and USB communications protocols allow a variety of autonomous and cable-connection options. Measurement precision of the order of 10-8 of full scale (e.g., pressure equivalent to 4000 m water depth, acceleration = +/- 3 g) allows observations of pressure and acceleration variations of 0.4 Pa and 0.3 μm s-2. Long-term variations in vertical acceleration are sensitive to displacement through the gravity gradient down to a level of roughly 2 cm, and variations in horizontal acceleration are sensitive to tilt down to a level of 0.03 μrad. With the large dynamic ranges, high sensitivities and broad bandwidth (6 Hz to DC), ground motion associated with microseisms, strong and weak seismic ground motion, tidal loading, and slow and rapid geodynamic deformation - all normally studied using disparate instruments - can be observed with a single tool. Installation in the marine environment is accomplished by pushing the tool roughly 1 m vertically below the seafloor with a submersible or remotely operated vehicle, with no profile remaining above the seafloor to cause current-induced noise. The weight of the tool is designed to match the sediment it displaces to

  1. Fibular taping does not influence ankle dorsiflexion range of motion or balance measures in individuals with chronic ankle instability.

    Science.gov (United States)

    Wheeler, Todd J; Basnett, Curtis R; Hanish, Michael J; Miriovsky, Daniel J; Danielson, Erin L; Barr, J B; Threlkeld, A Joseph; Grindstaff, Terry L

    2013-11-01

    To determine the effects of fibular taping on ankle dorsiflexion range of motion (ROM) and dynamic balance in individuals with chronic ankle instability (CAI). Single-blind, randomized crossover. Twenty-three individuals (age=23.4 ± 2.5 years, height=171.6 ± 12.4 cm, mass=71.5±13.1 kg) with CAI were allocated to either a fibular taping intervention or sham taping intervention (tape applied without tension) over the course of two visits. Weight-bearing ankle dorsiflexion ROM and components of the Star Excursion Balance Test (SEBT) were measured before and after intervention. There was not a significant change in ankle dorsiflexion ROM when comparing the taping interventions (F1,43=1.03, P=.32), but both interventions resulted in a small increase (F1,43=8.07, P=.007) in dorsiflexion ROM (pre=36.7° ± 6.9°, post=37.7° ± 6.2°). This increase in ROM did not exceed the established minimal detectable change for dorsiflexion ROM. Fibular taping with tension produced an increase (F1,41=5.84, P=.02) (pre=69.0 ± 9.1%, post=70.6±8.6%) in posterolateral reach distance when compared to taping without tension (pre=72.7 ± 11.0%, post=71.4 ± 9.6%), but this increase did not exceed the established minimal detectable change. There was not a significant change in dynamic balance between groups for the anterior (F1,41=2.33, P=.14) and posteromedial (F1,41=.41, P=.53) reach directions. Although small changes in ankle dorsiflexion ROM and posterolateral reach distances were observed, these changes did not exceed established minimal detectable change values for these measures. These results suggest that the benefits of fibular taping are not related to an increase in ankle dorsiflexion ROM or dynamic balance. Copyright © 2013 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  2. Wide range of body composition measures are associated with cognitive function in community-dwelling older adults.

    Science.gov (United States)

    Won, Huiloo; Abdul Manaf, Zahara; Mat Ludin, Arimi Fitri; Shahar, Suzana

    2017-04-01

    Studies of the association between body composition, both body fat and body muscle, and cognitive function are rarely reported. The aim of the present study was to determine the association between a wide range of body composition measures with cognitive function in older adults. A total of 2322 Malaysian older adults aged 60 years and older were recruited using multistage random sampling in a population-based cross-sectional study. Out of 2322 older adults recruited, 2309 (48% men) completed assessments on cognitive function and body composition. Cognitive functions were assessed using the Malay version of the Mini-Mental State Examination, the Bahasa Malaysia version of Montreal Cognitive Assessment, Digit Span Test, Digit Symbol Test and Rey Auditory Verbal Learning Test. Body composition included body mass index, mid-upper arm circumference, waist circumference, calf circumference, waist-to-hip ratio, percentage body fat and skeletal muscle mass. The association between body composition and cognitive functions was analyzed using multiple linear regression. After adjustment for age, education years, hypertension, hypercholesterolemia, diabetes mellitus, depression, smoking status and alcohol consumption, we found that calf circumference appeared as a significant predictor for all cognitive tests among both men and women (P < 0.05), except for the Rey Auditory Verbal Learning Test. Waist-to-hip ratio was detected as a significant predictor for all cognitive tests among women (P < 0.05), but was only a significant predictor for the Bahasa Malaysia version of Montreal Cognitive Assessment among men (P < 0.05). These results suggest that there is a need to maintain muscle mass and lower adipose tissue among older adults for optimal cognitive function. Geriatr Gerontol Int 2017; 17: 554-560. © 2016 Japan Geriatrics Society.

  3. Enso-like cyclicity In Late Pleistocene varve thickness measurements from two alpine lakes, Wind River Range, Wyoming, USA

    Science.gov (United States)

    Dahms, D. E.; Noren, A. J.; Geiss, C. E.; Dorale, J. A.; Myrbo, A.

    2011-12-01

    Spectral analyses of varve thickness measurements in sediment cores from two moraine-dammed lakes in the Wind River Range of Wyoming, USA, reveal a 2.8-to-8-yr cyclicity consistent with that expressed by ENSO. The lakes [Louis Lake (42.596°N,108.846°W, 2610 m and nearby Fiddlers Lake 42.6312°N, 108.8786°W, 2868 m] and hold the possibility of longer records of mid-continental climate change even into the last interglacial. Nine macrofossil-based 14C ages (AMS) combined with varve thicknesses indicate the lakes were deep enough during the LGM to form and preserve varves and that the minimum age for the lacustrine sediments here is ~20 kyrs. The ENSO signal is most robust in the Louis Lake varves, displaying high spectral power across the entire band of frequencies associated with ENSO. Analysis of the Fiddlers Lake varves yield predictably less significant results, a consequence of the different geomorphic settings of these two lakes. Specifically, (1) Louis Lake has a large catchment and receives surface water input from a stream, which has delivered a large quantity of sediment to the lake margin and deposited a substantial delta. In this setting, variations in precipitation appear closely linked to sediment delivery to the lake, and are reflected in sediment distributions, while (2) Fiddlers Lake is located in a small re-entrant basin with a relatively insignificant catchment area and fed almost entirely by groundwater and direct rain/snow events, with little surface runoff; (3) the deeper water of Louis Lake aids in the formation and preservation of varves, while (4) lake level fluctuations in the shallower Fiddlers Lake directly affect varve creation and preservation (the onset of glaciation in the Fiddlers Lake core is represented by thick sediment packages that eventually thin to varves by ~1m up-core). The significant ENSO-like periodicities in the the varved sediments in these lakes suggests that the effects of ENSO forcing were felt far into the western

  4. Fluorescent sensors for the basic metabolic panel enable measurement with a smart phone device over the physiological range.

    Science.gov (United States)

    Awqatty, Becker; Samaddar, Shayak; Cash, Kevin J; Clark, Heather A; Dubach, J Matthew

    2014-10-21

    The advanced functionality of portable devices such as smart phones provides the necessary hardware to potentially perform complex diagnostic measurements in any setting. Recent research and development have utilized cameras and data acquisition properties of smart phones to create diagnostic approaches for a variety of diseases or pollutants. However, in concentration measurements, such as blood glucose, the performance of handheld diagnostic devices depends largely on the sensing mechanism. To expand measurements to multiple components, often necessary in medical tests, with a single diagnostic device, robust platform based sensors are needed. Here, we developed a suite of dual wavelength fluorescent sensors with response characteristics necessary to measure each component of a basic metabolic panel, a common clinical measurement. Furthermore, the response of these sensors could be measured with a simple optical setup to convert a smart phone into a fluorescence measurement instrument. This approach could be used as a mobile basic metabolic panel measurement system for point of care diagnostics.

  5. Close Range Photogrammetry in Space - Measuring the On-Orbit Clearance between Hardware on the International Space Station

    Science.gov (United States)

    Liddle, Donn

    2017-01-01

    When photogrammetrists read an article entitled "Photogrammetry in Space" they immediately think of terrestrial mapping using satellite imagery. However in the last 19 years the roll of close range photogrammetry in support of the manned space flight program has grown exponentially. Management and engineers have repeatedly entrusted the safety of the vehicles and their crews to the results of photogrammetric analysis. In February 2010, the Node 3 module was attached to the port side Common Berthing Mechanism (CBM) of the International Space Station (ISS). Since this was not the location at which the module was originally designed to be located on the ISS, coolant lines containing liquid ammonia, were installed externally from the US Lab to Node 3 during a spacewalk. During mission preparation I had developed a plan and a set of procedures to have the astronauts acquire stereo imagery of these coolant lines at the conclusion of the spacewalk to enable us to map their as-installed location relative to the rest of the space station. Unfortunately, the actual installation of the coolant lines took longer than expected and in an effort to wrap up the spacewalk on time, the mission director made a real-time call to drop the photography. My efforts to reschedule the photography on a later spacewalk never materialized, so rather than having an as-installed model for the location of coolant lines, the master ISS CAD database continued to display an as-designed model of the coolant lines. Fast forward to the summer of 2015, the ISS program planned to berth a Japanese cargo module to the nadir Common Berthing Mechanism (CBM), immediately adjacent to the Node 3 module. A CAD based clearance analysis revealed a negative four inch clearance between the ammonia lines and a thruster nozzle on the port side of the cargo vehicle. Recognizing that the model of the ammonia line used in the clearance analysis was "as-designed" rather than "as-installed", I was asked to determine the

  6. A meta-analysis of echocardiographic measurements of the left heart for the development of normative reference ranges in a large international cohort

    DEFF Research Database (Denmark)

    Møgelvang, Rasmus

    2014-01-01

    AIM: To develop age-, sex-, and ethnic-appropriate normative reference ranges for standard echocardiographic measurements of the left heart by combining echocardiographic measurements obtained from adult volunteers without clinical cardiovascular disease or significant cardiovascular risk factors......, from multiple studies around the world. METHODS AND RESULTS: The Echocardiographic Normal Ranges Meta-Analysis of the Left heart (EchoNoRMAL) collaboration was established and population-based data sets of echocardiographic measurements combined to perform an individual person data meta-analysis. Data...... and 95th centile of each measurement against age. CONCLUSION: This unique data set represents a large, multi-ethnic cohort of subjects resident in a wide range of countries. The resultant reference ranges will have wide applicability for normative data based on age, sex, and ethnicity....

  7. Characteristics and reference ranges of Insulin-Like Growth Factor-I measured with a commercially available immunoassay in 724 healthy adult Caucasians

    DEFF Research Database (Denmark)

    Andreassen, Mikkel; Nielsen, Kaspar Renÿ; Kristensen, Lars Østergaard

    2009-01-01

    BACKGROUND AND OBJECTIVE: Measurements of Insulin-Like Growth Factor-I (IGF-I) play a pivotal role in the evaluation of the growth hormone-IGF-I axis. Due to assay variation IGF-I reference ranges are assay specific. We provide serum IGF-I reference ranges for adult men and women obtained...

  8. Measurements of the Complex Permittivity of Liquid Helium-4 in the Millimeter Wave Range by a Whispering Gallery Mode Resonator

    Science.gov (United States)

    Smorodin, A. V.; Rybalko, A. S.; Konstantinov, D.

    2017-06-01

    We report an experimental study of the electrical properties of liquid helium-4 in the temperature range 1.2-3 K. The experiment is carried out in the millimeter wave range using a whispering gallery mode dielectric resonator, and the complex permittivity of liquid helium is extracted from the data using the resonant perturbation method. The results for the temperature dependence of the dielectric constant are consistent with the previous studies. In addition, we find strong enhancement of the loss tangent around the superfluid transition temperature.

  9. Calorimetry for dose measurement at electron accelerators in the 80-120 keV energy range

    DEFF Research Database (Denmark)

    Helt-Hansen, J.; Miller, A.; Duane, S.

    2005-01-01

    Calorimeters for dose measurement at low-energy electron accelerator energies (80-120 keV) are described. Three calorimeters with different characteristics were designed and their dose response and measurement uncertainties were characterized. The heated air between the beam exit window and the c...

  10. Associations of self-report measures with gait, range of motion and proprioception in patients with lumbar spinal stenosis.

    Science.gov (United States)

    Conrad, Bryan P; Shokat, Maximilian S; Abbasi, Abdullah Z; Vincent, Heather K; Seay, Amanda; Kennedy, David J

    2013-09-01

    Spinal stenosis is defined as neurogenic claudication due to narrowing of the spinal canal lumen diameter. As the disease progresses, ambulation and gait may be impaired. Self-report measures are routinely used in the clinical setting to capture data related to lumbar pain symptoms, function and perceived disability. The associations between self-report measures and objective measures of physical function in patients with lumbar spinal stenosis are not well characterized. The purpose of this study was to determine the correlation between self-reported assessments of function with objective biomechanical measures of function. 25 subjects were enrolled in this study. Subjects completed self-report questionnaires and biomechanical assessments of gait analysis, lumbar 3D ROM and lumbar proprioception. Correlations were determined between self-report measures and biomechanical data. The Oswestry Disability Index (ODI) was strongly correlated with stride length and gait velocity and weakly correlated with base of support. ODI was also weakly correlated with left lateral bending proprioception but not right lateral bending. The SF12 was not significantly correlated with any of the biomechanical measurements. Pain scores were weakly correlated with velocity, and base of support, and had no correlation any of the other biomechanical measures. There is a strong correlation between gait parameters and functional disability as measured with the ODI. Quantified gait analysis can be a useful tool to evaluate patients with lumbar spinal stenosis and to assess the outcomes of treatments on this group of patients. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. Coherent detection of spontaneous Brillouin scattering combined with Raman amplification for long range distributed temperature and strain measurements

    Science.gov (United States)

    Alahbabi, M. N.; Cho, Y. T.; Newson, T. P.

    2005-05-01

    Brillouin intensity and frequency measurements achieved temperature and strain to be unambiguously resolved with resolutions of 3.5°C and 85 μɛ at 50km. Frequency only measurements, achieved temperature or strain resolution of 1.7°C and 35 μɛ at 100km.

  12. Modelos de negócios para periódicos científicos eletrônicos de acesso aberto.

    OpenAIRE

    Katiúcia Araujo Gumeiro

    2011-01-01

    Trata-se de uma pesquisa que estuda o uso de modelos de negócios no contexto da publicação de periódicos científicos eletrônicos de acesso aberto, em que as diferenças disciplinares são consideradas, especificamente quanto às seguintes questões: velocidades de publicação exigidas, financiamentos e particularidades que envolvem a edição de um periódico científico. Tem como objetivo elaborar um modelo que permita identificar os elementos necessários para configurar um modelo de negócios adequad...

  13. O uso de modelos de negócios por editoras de periódicos científicos eletrônicos de acesso aberto

    OpenAIRE

    Gumieiro,Katiucia Araujo; Costa, Sely Maria de Souza

    2012-01-01

    Estuda o uso de modelos de negócios, no contexto da atividade de publicação de periódicos científicos eletrônicos de acesso aberto. Adicionalmente, discute as diferenças disciplinares, especificamente quanto às seguintes questões: velocidades de publicação exigidas, financiamentos e particularidades que envolvem a edição de um periódico científico. O estudo objetivou identificar os componentes necessários para configurar modelos de negócios adequados à atividade de publicação de periódicos ci...

  14. Acoustic and Perceptual Measurement of Expressive Prosody in High-Functioning Autism: Increased Pitch Range and What it Means to Listeners

    Science.gov (United States)

    Nadig, Aparna; Shaw, Holly

    2012-01-01

    Are there consistent markers of atypical prosody in speakers with high functioning autism (HFA) compared to typically-developing speakers? We examined: (1) acoustic measurements of pitch range, mean pitch and speech rate in conversation, (2) perceptual ratings of conversation for these features and overall prosody, and (3) acoustic measurements of…

  15. Final Environmental Assessment for the Bridge Replacement and Scour Protection Measures at Avon Park Air Force Range, Florida

    Science.gov (United States)

    2012-03-01

    documented at the site or are known to occur at or near the project locations: Eastern indigo snake, (Drymarchon corais Avon Park Air Force Range...Eastem indigo snake (D1ymarchon corais couperi) The threatened eastem indigo snake (indigo snake) is a large snake which can reach lengths of up to

  16. L'aquila e il littorio: direttive, strutture e strumenti della propaganda fascista negli Stati Uniti d'America (1922-1941)

    OpenAIRE

    Di Legge, Francesco

    2015-01-01

    L’oggetto di questa ricerca è la propaganda fascista negli Stati Uniti nel periodo compreso tra la marcia su Roma e l’ingresso dell’America nella seconda guerra mondiale. In particolare, questo lavoro intende delineare gli orientamenti, i temi, le strutture e gli strumenti di propaganda utilizzati dal regime fascista per migliorare la propria immagine presso il pubblico americano e per sviluppare un senso di rinnovato orgoglio nazionale in seno alle numerose comunità italo-americane, al fine ...

  17. Espressione genica e proteica dell’albumina negli adipociti umani maturi. Relazione tra albuminemia e tessuto adiposo nei pazienti in trattamento dialitico.

    OpenAIRE

    Sirico, Maria Luisa

    2013-01-01

    Scopo: Lo scopo di questo lavoro era quello di indagare l’espressione genica dell’albumina negli adipociti umani maturi, la regolazione di tale espressione da parte dell’infiammazione e il contributo del tessuto adiposo ai livelli circolanti di albumina. Metodi: Campioni di tessuto adiposo sono stati prelevati da soggetti sani e infiammati. Sono state effettuate analisi di espressione genica (RT-PCR e Real-Time PCR) e proteica (Western Blot ) sugli adipociti e preadipociti estratti. Inoltr...

  18. Ankle joint range of motion measurements in spastic cerebral palsy children: intraobserver and interobserver reliability and reproducibility of goniometry and visual estimation.

    Science.gov (United States)

    Allington, Nanni J; Leroy, Nathalie; Doneux, Carole

    2002-07-01

    The aim of this study was to assess the intra- and interobserver reliability and reproducibility of goniometry and visual estimation of ankle joint range of motion measurements in children with spastic cerebral palsy. Forty-six ankles of 24 spastic cerebral palsy children were measured under a strict protocol. The global mean measurement error was 5 degrees (SD, 5 degrees) for intra- and interobserver measurements and 3 degrees (SD, 3 degrees) for goniometry versus visual estimation. Statistical analysis showed a high reliability for intra- and interobserver measurements (r>0.75), between visual estimation and goniometry (correlation coefficient, r>0.967; concordance coefficient, r>0.957). Both visual estimation and goniometry ankle range-of-motion measurements are reliable and reproducible in spastic cerebral palsy children if a strict but simple protocol is applied.

  19. Radiological Assessment of the Sacrofemoral Angle: A Novel Method to Measure the Range of Hip Joint Flexion

    Directory of Open Access Journals (Sweden)

    Xian-Zhao Wei

    2015-01-01

    Conclusions: Using the SFA, to evaluate RHF could prevent compromised measurements due to the movements of pelvis and lumbar spine during hip flexion, and is, therefore, a more accurate and objective method with reasonable reliability and validity.

  20. Defining a functionally distinct subset of human memory CD4+ T cells that are CD25POS and FOXP3NEG.

    Science.gov (United States)

    Triplett, Todd A; Curti, Brendan D; Bonafede, Peter R; Miller, William L; Walker, Edwin B; Weinberg, Andrew D

    2012-07-01

    Surface expression of the IL-2 receptor α-chain (CD25) has been used to discriminate between CD4(+) CD25(HI) FOXP3(+) regulatory T (Treg) cells and CD4(+) CD25(NEG) FOXP3(-) non-Treg cells. However, this study reports that the majority of resting human memory CD4(+) FOXP3(-) T cells expresses intermediate levels of CD25 and that CD25 expression can be used to delineate a functionally distinct memory subpopulation. The CD25(NEG) memory T-cell population contains the vast majority of late differentiated cells that respond to antigens associated with chronic immune responses and are increased in patients with systemic lupus erythematosus (SLE). In contrast, the CD25(INT) memory T cells respond to antigens associated with recall responses, produce a greater array of cytokines, and are less dependent on costimulation for effector responses due to their expression of CD25. Lastly, compared to the CD25(NEG) and Treg-cell populations, the CD25(INT) memory population is lost to a greater degree from the blood of cancer patients treated with IL-2. Collectively, these results show that in humans, a large proportion of CD4(+) memory T cells express intermediate levels of CD25, and this CD25(INT) FOXP3(-) subset is a functionally distinct memory population that is uniquely affected by IL-2. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Modelo de Negócio: Uma Abordagem Evolutiva no Setor de SVA sob a Ótica do Método Canvas.

    Directory of Open Access Journals (Sweden)

    Fábio Luiz Zandoval Bonazzi

    2015-11-01

    Full Text Available Este estudo objetivou analisar e descrever o modelo de negócios da empresa Movile e sua forma de criação e captura de valor. Trata-se de uma pesquisa qualitativa com foco empírico, baseada em um estudo de caso único realizado por meio de entrevista, análise documental e observações indiretas da empresa. O estudo permitiu analisar a concepção do modelo de negócio atual da empresa com base em todo em seu processo evolutivo delineado pelas alterações vivenciadas pelo segmento de serviço de valor agregado – SVA na última década, além de inferir sobre sua participação na cadeia de valor no setor de telecomunicações e descrever as nove dimensões de seu modelo de acordo com o Business Model Canvas – BMC (OSTERWALDER E PIGNEUR, 2010. Como contribuição teórica destaca-se a aproximação de antigos autores como Penrose (2006 e Chandler Jr. (2000 com o tema modelo de negócio, bem como o dinamismo que os mesmos puderam fornecer à ferramenta CANVAS, essencialmente caracterizada como um método estático, a partir da discussão do processo evolutivo organizacional.

  2. A gestão ordinária dos pequenos negócios: outro olhar sobre a gestão em estudos organizacionais

    Directory of Open Access Journals (Sweden)

    Alexandre de Pádua Carrieri

    2014-12-01

    Full Text Available Neste artigo, o objetivo é apresentar a gestão ordinária, que foge aos parâmetros gerencialistas ao focar o cotidiano do homem comum que administra negócios ordinários, os empreendimentos familiares, com suas relações sociais estabelecidas, sua forma de organizar seus negócios, suas estratégias de sobrevivência, seus usos e sentidos dos espaços – de negócio e de família – e a rede de relações tecidas por eles. Neste texto, questiona-se a perspectiva da administração como única, baseada em um conhecimento tido como puro ou neutro (restrito ao racional, absoluto e universal (excludente de outros saberes concorrentes e que triunfou política e economicamente por meio das tecnologias de gestão. Em contrapartida a esse posicionamento, defende-se que se devem levar em consideração os fatores históricos, sociais, culturais e identitários que diferenciam os sujeitos e na prática cotidiana pluralizam a gestão. Portanto, há outras abordagens capazes de contribuir para o avanço do conhecimento científico na área de estudos organizacionais, sendo a gestão ordinária uma dessas abordagens.

  3. I sistemi biometrici lo sviluppo dei mercati negli Usa, UE e nel mondo. La normativa frena quello italiano

    Directory of Open Access Journals (Sweden)

    Franco Zucchetti

    2007-04-01

    Full Text Available Negli ultimi anni il settore biometrico sta compiendo, a livello mondiale, importanti passi in avanti soprattutto in termini di sviluppo e di diffusione. Questo trend positivo riguarda il mondo anglosassone e, in particolare, la realtà statunitense dove i sistemi biometrici vengono utilizzati, nelle più svariate situazioni, sia come controllo della sicurezza fisica delle persone, sia come terminali per l’autorizzazione all’accesso. La stessa diffusione non è riscontrabile nella maggior parte dei Paesi europei e in Italia dove raffrontiamo una realtà assai atipica nella quale la biometria fa un gran parlare di sé ma, in concreto, viene utilizzata con molta difficoltà. Tuttavia, un punto di contatto tra tutti gli attori europei ed extraeuropei può essere individuato nello sviluppo del settore relativo al riconoscimento biometrico applicato ai passaporti ed alle carte di identità. Il processo di globalizzazione ha generato, infatti, grandi masse di individui in continuo e costante movimento da un Paese all’altro e, contestualmente, ha prodotto una crescente domanda di sicurezza soprattutto nei confronti della minaccia terroristica. Appare chiaro, quindi, come l’identificazione certa delle persone diventi una necessità e debba presentare tecnologie simili per essere utilizzate ovunque.

  4. Folga Organizacional em Unidades de Negócios de Empresa Descentralizada na Percepção dos Controllers

    Directory of Open Access Journals (Sweden)

    Ilse Maria Beuren

    2013-05-01

    Full Text Available O estudo objetiva examinar determinantes da folga organizacional em unidades de negócios (UN de empresa descentralizada na percepção dos controllers. Pesquisa descritiva, com abordagem qualitativa, foi realizada por meio de um estudo de caso em cinco UN de empresa multinacional do setor de embalagens. Entrevista estruturada foi realizada com os controllers da UN do Brasil e de quatro UN dos Estados Unidos, pautada no instrumento de pesquisa de Indjejikian e Matejka (2006. Na análise de conteúdo das respostas constata-se a existência de folga organizacional em maior ou menor proporção no alcance das metas orçamentárias; nas informações disponibilizadas sob o enfoque da assimetria entre o gerente geral da unidade e o controller corporativo; na autoridade das decisões relativas à gestão de pessoas e de mudanças nas técnicas e procedimentos contábeis; e na autonomia das UN. Conclui-se que os quatro determinantes da folga organizacional identificados na pesquisa de Indjejikian e Matejka (2006 também possuem relativa presença nas UN da empresa pesquisada, o que justifica ampliar o estudo para outras empresas e de futuras pesquisas explorar motivações para a folga organizacional e de novos determinantes.

  5. Regimes de convocação do ambientalismo nas revistas brasileiras de negócios

    Directory of Open Access Journals (Sweden)

    Jose Luiz Aidar Prado

    2012-12-01

    Full Text Available As tensões entre o discurso liberal-capitalista e os discursos antagonistas do ambientalismo revestem-se de um especial interesse no Brasil. Este artigo apresenta um estudo dos regimes de convocação das reportagens sobre meio ambiente publicadas em 2010 nas duas revistas brasileiras mais influentes de economia e negócios, cujos contratos de comunicação propõem a modalização de executivos e empresas em direção ao sucesso econômico. Seu objetivo é analisar como os enunciadores tematizam os antagonismos ambientais conservando seu contrato geral de comunicação sob o paradigma liberal. Para isso, o enunciador constitui um regime de mesmidade/alteridade, sendo que a mesmidade é construída nos termos da corrente reformista do ambientalismo, enquanto a ecologia profunda e a ecologia radical são apresentadas como alteridades. Os pontos nodais que suturam as cadeias de equivalência do campo discursivo do ambientalismo, nos termos da mesmidade ambiental reformista, ou “sustentabilidade”, são a tecnologia e a gestão eficiente, que restituem o enunciatário ao contrato de comunicação original.

  6. Listening for bats: the hearing range of the bushcricket Phaneroptera falcata for bat echolocation calls measured in the field.

    OpenAIRE

    Schul, J.; Matt, F; von Helversen, O

    2000-01-01

    The hearing range of the tettigoniid Phaneropterafalcata for the echolocation calls of freely flying mouseeared bats (Myotis myotis) was determined in the field. The hearing of the insect was monitored using hook electrode recordings from an auditory interneuron, which is as sensitive as the hearing organ for frequencies above 16 kHz. The flight path of the bat relative to the insect's position was tracked by recording the echolocation calls with two microphone arrays, and calculating the bat...

  7. A benchmark for protein dynamics: Ribonuclease A measured by neutron scattering in a large wavevector-energy transfer range

    Energy Technology Data Exchange (ETDEWEB)

    Wood, Kathleen [Institut Laue Langevin, BP 156, 38042 Grenoble Cedex 9 (France); Department of Membrane Biochemistry, Max Planck Institute of Biochemistry, Am Klopferspitz 18, D-82152 Martinsried (Germany); Caronna, Chiara [European Synchrotron Radiation Facility, B.P. 220, 38043 Grenoble (France); Dipartimento di Scienze Fisiche ed Astronomiche, Universita di Palermo, Via Archirafi 36, 90123, Palermo (Italy); Fouquet, Peter [Institut Laue Langevin, BP 156, 38042 Grenoble Cedex 9 (France); Haussler, Wolfgang [Forschungsneutronenquelle Heinz Maier-Leibnitz (FRM II), 85747 Garching (Germany); Technische Universitaet Muenchen, Physik Department E21, Lichtenbergstrasse 1, 85747 Garching (Germany); Natali, Francesca [INFM-CNR OGG and CRS-SOFT, c/o ILL, 6 Rue Jules Horowitz, BP 156-38042, Grenoble Cedex 9 (France); Ollivier, Jacques [Institut Laue Langevin, BP 156, 38042 Grenoble Cedex 9 (France); Orecchini, Andrea [Dipartimento di Fisica, Universita di Perugia, Via Pascoli, 06123 Perugia (Italy); CNR-INFM CRS SOFT c/o Dipartimento di Fisica, Universita La Sapienza, p.le Aldo Moro 4, 00185 Roma (Italy); Plazanet, Marie [European Laboratory for Non-Linear Spectroscopy, University of Florence, Via N. Carrara 1, 50019 Sesto Fiorentino (Italy); CNR-INFM CRS SOFT c/o Dipartimento di Fisica, Universita La Sapienza, p.le Aldo Moro 4, 00185 Roma (Italy); Zaccai, Giuseppe [Institut Laue Langevin, BP 156, 38042 Grenoble Cedex 9 (France)], E-mail: zaccai@ill.fr

    2008-04-18

    The dynamics of Ribonuclease A was explored in the full range of time and length-scales accessible by neutron spectroscopy, on time-of-flight, backscattering and spin-echo spectrometers. Samples were examined in dry and hydrated powder forms and in concentrated and dilute solutions. The aim of the study was an experimental characterisation of the full variety of protein dynamics arising from stabilisation forces. The results provide a benchmark against which other sample dynamics can be compared.

  8. Validation of Attitude and Heading Reference System and Microsoft Kinect for Continuous Measurement of Cervical Range of Motion Compared to the Optical Motion Capture System.

    Science.gov (United States)

    Song, Young Seop; Yang, Kyung Yong; Youn, Kibum; Yoon, Chiyul; Yeom, Jiwoon; Hwang, Hyeoncheol; Lee, Jehee; Kim, Keewon

    2016-08-01

    To compare optical motion capture system (MoCap), attitude and heading reference system (AHRS) sensor, and Microsoft Kinect for the continuous measurement of cervical range of motion (ROM). Fifteen healthy adult subjects were asked to sit in front of the Kinect camera with optical markers and AHRS sensors attached to the body in a room equipped with optical motion capture camera. Subjects were instructed to independently perform axial rotation followed by flexion/extension and lateral bending. Each movement was repeated 5 times while being measured simultaneously with 3 devices. Using the MoCap system as the gold standard, the validity of AHRS and Kinect for measurement of cervical ROM was assessed by calculating correlation coefficient and Bland-Altman plot with 95% limits of agreement (LoA). MoCap and ARHS showed fair agreement (95% LoA10°) for measuring ROM in all directions. Intraclass correlation coefficient (ICC) values between MoCap and AHRS in -40° to 40° range were excellent for flexion/extension and lateral bending (ICC>0.9). ICC values were also fair for axial rotation (ICC>0.8). ICC values between MoCap and Kinect system in -40° to 40° range were fair for all motions. Our study showed feasibility of using AHRS to measure cervical ROM during continuous motion with an acceptable range of error. AHRS and Kinect system can also be used for continuous monitoring of flexion/extension and lateral bending in ordinary range.

  9. Areal-averaged trace gas emission rates from long-range open-path measurements in stable boundary layer conditions

    Directory of Open Access Journals (Sweden)

    K. Schäfer

    2012-07-01

    Full Text Available Measurements of land-surface emission rates of greenhouse and other gases at large spatial scales (10 000 m2 are needed to assess the spatial distribution of emissions. This can be readily done using spatial-integrating micro-meteorological methods like flux-gradient methods which were evaluated for determining land-surface emission rates of trace gases under stable boundary layers. Non-intrusive path-integrating measurements are utilized. Successful application of a flux-gradient method requires confidence in the gradients of trace gas concentration and wind, and in the applicability of boundary-layer turbulence theory; consequently the procedures to qualify measurements that can be used to determine the flux is critical. While there is relatively high confidence in flux measurements made under unstable atmospheres with mean winds greater than 1 m s−1, there is greater uncertainty in flux measurements made under free convective or stable conditions. The study of N2O emissions of flat grassland and NH3 emissions from a cattle lagoon involves quality-assured determinations of fluxes under low wind, stable or night-time atmospheric conditions when the continuous "steady-state" turbulence of the surface boundary layer breaks down and the layer has intermittent turbulence. Results indicate that following the Monin-Obukhov similarity theory (MOST flux-gradient methods that assume a log-linear profile of the wind speed and concentration gradient incorrectly determine vertical profiles and thus flux in the stable boundary layer. An alternative approach is considered on the basis of turbulent diffusivity, i.e. the measured friction velocity as well as height gradients of horizontal wind speeds and concentrations without MOST correction for stability. It is shown that this is the most accurate of the flux-gradient methods under stable conditions.

  10. Measures of range of motion and strength among healthy women with differing quality of lower extremity movement during the lateral step-down test.

    Science.gov (United States)

    Rabin, Alon; Kozol, Zvi

    2010-12-01

    Cross-sectional. To determine the association between hip and ankle range-of-motion measures, as well as measures of hip muscle strength, with measures of quality of lower extremity movement, as assessed visually during the lateral step-down test in healthy women. Altered lower extremity movement pattern consisting of excessive femoral adduction and internal rotation, leading to excessive knee valgus alignment, is associated with increased risk of knee ligament injury, as well as patellofemoral pain syndrome. Previous investigations of lower extremity kinematics, using 3-dimensional motion analysis systems, document an inconsistent association between hip muscle strength and lower extremity movement pattern. Currently, it is unknown whether differences in hip muscle strength or other physical measures exist among women with differing quality of lower extremity movement as assessed by visual observation. Two physical therapists assessed the quality of movement during the lateral step-down among 29 healthy women (mean ± SD age, 24.3 ± 3.2 years). Subjects were instructed on the optimal movement pattern prior to performing the test. The quality of movement was categorized as "good" or "moderate," based on a previously established 6-point scale. Several measures of hip strength (handheld dynamometer) and hip and ankle range of motion (fluid-filled inclinometer and universal goniometer) were also assessed. Differences in strength and range-of-motion measures between women with good and women with moderate quality of movement were assessed with a Mann-Whitney U test. Both examiners found decreased ankle dorsiflexion range of motion, as measured with the knee bent (Pdorsiflexion range of motion compared to women with a good quality of movement. Clinicians should consider evaluating ankle dorsiflexion range of motion when observing an altered lower extremity movement pattern during the lateral step-down test.

  11. Proton clouds to measure long-range contacts between nonexchangeable side chain protons in solid-state NMR.

    Science.gov (United States)

    Sinnige, Tessa; Daniëls, Mark; Baldus, Marc; Weingarth, Markus

    2014-03-26

    We show that selective labeling of proteins with protonated amino acids embedded in a perdeuterated matrix, dubbed 'proton clouds', provides general access to long-range contacts between nonexchangeable side chain protons in proton-detected solid-state NMR, which is important to study protein tertiary structure. Proton-cloud labeling significantly improves spectral resolution by simultaneously reducing proton line width and spectral crowding despite a high local proton density in clouds. The approach is amenable to almost all canonical amino acids. Our method is demonstrated on ubiquitin and the β-barrel membrane protein BamA.

  12. A system to measure isomeric state half-lives in the 10 ns to 10 μs range

    Energy Technology Data Exchange (ETDEWEB)

    Toufen, D. L., E-mail: dennis@if.usp.br [Institute of Physics, University of São Paulo, C.P. 66318, 05315-970 São Paulo, São Paulo (Brazil); Federal Institute of Education, Science and Technology of São Paulo - IFSP, 07115-000 Guarulhos, São Paulo (Brazil); Allegro, P. R. P.; Medina, N. H.; Oliveira, J. R. B.; Cybulska, E. W.; Seale, W. A.; Ribas, R. V. [Institute of Physics, University of São Paulo, C.P. 66318, 05315-970 São Paulo, São Paulo (Brazil); Linares, R. [Fluminense Federal University, 24220-900 Niterói, Rio de Janeiro (Brazil); Silveira, M. A. G. [Universitary Center of FEI, 09850-901 São Bernardo do Campo, São Paulo (Brazil)

    2014-07-15

    The Isomeric State Measurement System (SISMEI) was developed to search for isomeric nuclear states produced by fusion-evaporation reactions. The SISMEI consists of 10 plastic phoswich telescopes, two lead shields, one NaI(Tl) scintillation detector, two Compton suppressed HPGe γ-ray detectors, and a cone with a recoil product catcher. The new system was tested at the 8 UD Pelletron tandem accelerator of the University of São Paulo with the measurement of two known isomeric states: {sup 54}Fe, 10{sup +} state (E = 6527.1 (11) keV, T{sub 1/2} = 364(7) ns) and the 5/2{sup +} state of {sup 19}F (E = 197.143 (4) keV, T{sub 1/2} = 89.3 (10) ns). The results indicate that the system is capable of identifying delayed transitions, of measuring isomeric state lifetimes, and of identifying the feeding transitions of the isomeric state through the delayed γ-γ coincidence method. The measured half-life for the 10{sup +} state was T{sub 1/2} = 365(14) ns and for the 5/2{sup +} state, 100(36) ns.

  13. Thermoregulation of the bovine scrotum 1: measurements of free-range animals in a paddock and pen

    Science.gov (United States)

    Wallage, Andrea L.; Johnston, S. D.; Lisle, A. T.; Beard, L.; Lees, A. M.; Collins, C. W.; Gaughan, J. B.

    2017-08-01

    The bull's scrotum and scrotal cord vasculature has traditionally been regarded as a thermoregulatory device for maintaining optimal testicular temperature for normal spermatogenesis. This assumption has mostly been derived from discrete measurements using thermocouples with limited data correlating continuous scrotal temperature (ST) to body temperature (BT). From mid-summer to early autumn, four Wagyu bulls (9-18 months) were surgically implanted with two data loggers (DL) logging at 30 min intervals: one on the right hand side flank and the other was attached to the visceral vaginal tunic of the mid-testis. Bulls were firstly housed in a paddock (PK) for 13 days and then moved to individual pens (IP), again for 13 days. Repeated measures analysis modelled the long-term and diurnal trends in BT and ST. While both day and time of day (TOD) were significant effects for ST at both housing locations ( P thermoregulation capacity.

  14. 10 CFR Appendix I to Subpart B of... - Uniform Test Method for Measuring the Energy Consumption of Conventional Ranges, Conventional...

    Science.gov (United States)

    2010-01-01

    ... (228.6±1.3 mm) in diameter, approximately 3.0 inches (76 mm) high and shall weigh 19±0.1 lbs (8.62±0.05... measuring the electrical energy consumption of conventional ovens and cooking tops shall have a resolution... microwave ovens shall have a resolution of 0.1 watt-hour (0.36 kJ) or less and a maximum error no greater...

  15. Polarization Diversity Image-Reject Homodyne Receiver for Directional Radial Velocity Measurements in Light Detection and Ranging (LIDAR) Instruments

    DEFF Research Database (Denmark)

    2015-01-01

    The present invention relates to an improved method and a LIDAR system comprising an emitter for emission of a coherent electromagnetic EM signal and a transmitting optical arrangement configured to transmit the electromagnetic signal towards a measurement area. By the method and system, detectio...... of both the polarized and depolarized backscattered EM signal is obtained, whereby an improved signal-to-noise ratio is obtained....

  16. Quantitative methanol-burning lung model for validating gas-exchange measurements over wide ranges of FIO2.

    Science.gov (United States)

    Miodownik, S; Melendez, J; Carlon, V A; Burda, B

    1998-06-01

    The methanol-burning lung model has been used as a technique for generating a predictable ratio of carbon dioxide production (VCO2) to oxygen consumption (VO2) or respiratory quotient (RQ). Although an accurate RQ can be generated, quantitatively predictable and adjustable VO2 and VCO2 cannot be generated. We describe a new burner device in which the combustion rate of methanol is always equal to the infusion rate of fuel over an extended range of O2 concentrations. This permits the assembly of a methanol-burning lung model that is usable with O2 concentrations up to 100% and provides continuously adjustable and quantitative VO2 (69-1,525 ml/min) and VCO2 (46-1,016 ml/min) at a RQ of 0.667.

  17. DEIMOS: a beamline dedicated to dichroism measurements in the 350-2500 eV energy range.

    Science.gov (United States)

    Ohresser, P; Otero, E; Choueikani, F; Chen, K; Stanescu, S; Deschamps, F; Moreno, T; Polack, F; Lagarde, B; Daguerre, J-P; Marteau, F; Scheurer, F; Joly, L; Kappler, J-P; Muller, B; Bunau, O; Sainctavit, Ph

    2014-01-01

    The DEIMOS (Dichroism Experimental Installation for Magneto-Optical Spectroscopy) beamline was part of the second phase of the beamline development at French Synchrotron SOLEIL (Source Optimisée de Lumière à Energie Intermédiaire du LURE) and opened to users in March 2011. It delivers polarized soft x-rays to perform x-ray absorption spectroscopy, x-ray magnetic circular dichroism, and x-ray linear dichroism in the energy range 350-2500 eV. The beamline has been optimized for stability and reproducibility in terms of photon flux and photon energy. The main end-station consists in a cryo-magnet with 2 split coils providing a 7 T magnetic field along the beam or 2 T perpendicular to the beam with a controllable temperature on the sample from 370 K down to 1.5 K.

  18. Determining Damping Trends from a Range of Cable Harness Assemblies on a Launch Vehicle Panel from Test Measurements

    Science.gov (United States)

    Smith, Andrew; Davis, R. Ben; LaVerde, Bruce; Jones, Douglas

    2012-01-01

    The team of authors at Marshall Space Flight Center (MSFC) has been investigating estimating techniques for the vibration response of launch vehicle panels excited by acoustics and/or aero-fluctuating pressures. Validation of the approaches used to estimate these environments based on ground tests of flight like hardware is of major importance to new vehicle programs. The team at MSFC has recently expanded upon the first series of ground test cases completed in December 2010. The follow on tests recently completed are intended to illustrate differences in damping that might be expected when cable harnesses are added to the configurations under test. This validation study examines the effect on vibroacoustic response resulting from the installation of cable bundles on a curved orthogrid panel. Of interest is the level of damping provided by the installation of the cable bundles and whether this damping could be potentially leveraged in launch vehicle design. The results of this test are compared with baseline acoustic response tests without cables. Damping estimates from the measured response data are made using a new software tool that employs a finite element model (FEM) of the panel in conjunction with advanced optimization techniques. This paper will report on the \\damping trend differences. observed from response measurements for several different configurations of cable harnesses. The data should assist vibroacoustics engineers to make more informed damping assumptions when calculating vibration response estimates when using model based analysis approach. Achieving conservative estimates that have more flight like accuracy is desired. The paper may also assist analysts in determining how ground test data may relate to expected flight response levels. Empirical response estimates may also need to be adjusted if the measured response used as an input to the study came from a test article without flight like cable harnesses.

  19. Investigation of Ozone Sources in California Using AJAX Airborne Measurements and Models: Implications for Stratospheric Intrusion and Long Range Transport

    Science.gov (United States)

    Ryoo, Ju-Mee; Johnson, Matthew S.; Iraci, Laura T.; Yates, Emma L.; Pierce, R. Bradley; Tanaka, Tomoaki; Gore, Warren

    2015-01-01

    High ozone concentrations at low altitudes near the surface were detected from airborne Alpha Jet Atmospheric eXperiment (AJAX) measurements on May 30, 2012. We investigate the causes of the elevated ozone concentrations using the airborne measurements and various models. GEOS-chem and WRF-STILT model simulations show that the contribution from local sources is small. From MERRA reanalysis, it is found that high potential vorticity (PV) is observed at low altitudes. This high PV appears to be only partially coming through the stratospheric intrusions because the air inside the high PV region is moist, which shows that mixing appears to be enhanced in the low altitudes. Considering that diabatic heating can also produce high PV in the lower troposphere, high ozone is partially coming through stratospheric intrusion, but this cannot explain the whole ozone concentration in the target areas of the western U.S. A back-trajectory model is utilized to see where the air masses originated. The air masses of the target areas came from the lower stratosphere (LS), upper (UT), mid- (MT), and lower troposphere (LT). The relative number of trajectories coming from LS and UT is low (7.7 and 7.6, respectively) compared to that from LT (64.1), but the relative ozone concentration coming from LS and UT is high (38.4 and 20.95, respectively) compared to that from LT (17.7). The air mass coming from LT appears to be mostly coming from Asia. Q diagnostics show that there is sufficient mixing along the trajectory to indicate that ozone from the different origins is mixed and transported to the western U.S. This study shows that high ozone concentrations can be detected by airborne measurements, which can be analyzed by integrated platforms such as models, reanalysis, and satellite data.

  20. Investigating Sources of Ozone over California Using AJAX Airborne Measurements and Models: Assessing the Contribution from Long Range Transport

    Science.gov (United States)

    Ryoo, Ju-Mee; Johnson, Matthew S.; Iraci, Laura T.; Yates, Emma L.; Gore, Warren

    2017-01-01

    High ozone (O3) concentrations at low altitudes (1.5e4 km) were detected from airborne Alpha Jet Atmospheric eXperiment (AJAX) measurements on 30 May 2012 off the coast of California (CA). We investigate the causes of those elevated O3 concentrations using airborne measurements and various models. GEOS-Chem simulation shows that the contribution from local sources is likely small. A back trajectory model was used to determine the air mass origins and how much they contributed to the O3 over CA. Low-level potential vorticity (PV) from Modern Era Retrospective analysis for Research and Applications 2 (MERRA-2) reanalysis data appears to be a result of the diabatic heating and mixing of airs in the lower altitudes, rather than be a result of direct transport from stratospheric intrusion. The Q diagnostic, which is a measure of the mixing of the air masses, indicates that there is sufficient mixing along the trajectory to indicate that O3 from the different origins is mixed and transported to the western U.S.The back-trajectory model simulation demonstrates the air masses of interest came mostly from the mid troposphere (MT, 76), but the contribution of the lower troposphere (LT, 19) is also significant compared to those from the upper troposphere/lower stratosphere (UTLS, 5). Air coming from the LT appears to be mostly originating over Asia. The possible surface impact of the high O3 transported aloft on the surface O3 concentration through vertical and horizontal transport within a few days is substantiated by the influence maps determined from the Weather Research and Forecasting Stochastic Time Inverted Lagrangian Transport (WRF-STILT) model and the observed increases in surface ozone mixing ratios. Contrasting this complex case with a stratospheric-dominant event emphasizes the contribution of each source to the high O3 concentration in the lower altitudes over CA. Integrated analyses using models, reanalysis, and diagnostic tools, allows high ozone values

  1. Measurements of the capture cross sections of natural silver in the resonance range with the time of flight technique

    Directory of Open Access Journals (Sweden)

    Šalamon L.

    2017-01-01

    Full Text Available Neutron capture cross section measurements have been performed at the time-of-flight facility GELINA of the EC-JRC-Geel. Prompt gamma rays, originating from a natural silver sample, were detected by a pair of C6D6 liquid scintillation detectors. The total energy detection principle in combination with the pulse height weighting technique has been used. In this contribution the experimental details together with the data reduction process are described. In addition, first results of calculations with REFIT are presented to verify the quality of recommended cross section data in the resolved resonance region.

  2. Investigating sources of ozone over California using AJAX airborne measurements and models: Assessing the contribution from long-range transport

    Science.gov (United States)

    Ryoo, Ju-Mee; Johnson, Matthew S.; Iraci, Laura T.; Yates, Emma L.; Gore, Warren

    2017-04-01

    High ozone (O3) concentrations at low altitudes (1.5-4 km) were detected from airborne Alpha Jet Atmospheric eXperiment (AJAX) measurements on 30 May 2012 off the coast of California (CA). We investigate the causes of those elevated O3 concentrations using airborne measurements and various models. GEOS-Chem simulation shows that the contribution from local sources is likely small. A back-trajectory model was used to determine the air mass origins and how much they contributed to the O3 over CA. Low-level potential vorticity (PV) from Modern Era Retrospective analysis for Research and Applications 2 (MERRA-2) reanalysis data appears to be a result of the diabatic heating and mixing of airs in the lower altitudes, rather than be a result of direct transport from stratospheric intrusion. The Q diagnostic, which is a measure of the mixing of the air masses, indicates that there is sufficient mixing along the trajectory to indicate that O3 from the different origins is mixed and transported to the western U.S. The back-trajectory model simulation demonstrates the air masses of interest came mostly from the mid troposphere (MT, 76%), but the contribution of the lower troposphere (LT, 19%) is also significant compared to those from the upper troposphere/lower stratosphere (UT/LS, 5%). Air coming from the LT appears to be mostly originating over Asia. The possible surface impact of the high O3 transported aloft on the surface O3 concentration through vertical and horizontal transport within a few days is substantiated by the influence maps determined from the Weather Research and Forecasting-Stochastic Time Inverted Lagrangian Transport (WRF-STILT) model and the observed increases in surface ozone mixing ratios. Contrasting this complex case with a stratospheric-dominant event emphasizes the contribution of each source to the high O3 concentration in the lower altitudes over CA. Integrated analyses using models, reanalysis, and diagnostic tools, allows high ozone values

  3. Measurement and Modeling of Short and Medium Range Order in Amorphous Ta2O5 Thin Films

    OpenAIRE

    Badri Shyam; Stone, Kevin H.; Riccardo Bassiri; Martin M. Fejer; Toney, Michael F.; Apurva Mehta

    2016-01-01

    Amorphous films and coatings are rapidly growing in importance. Yet, there is a dearth of high-quality structural data on sub-micron films. Not understanding how these materials assemble at atomic scale limits fundamental insights needed to improve their performance. Here, we use grazing-incidence x-ray total scattering measurements to examine the atomic structure of the top 50?100?nm of Ta2O5 films; mirror coatings that show high promise to significantly improve the sensitivity of the next g...

  4. Measurement of long-range angular correlations and azimuthal anisotropies in high-multiplicity $p$$+$Au collisions at $\\sqrt{s_{_{NN}}}=200$ GeV

    CERN Document Server

    Aidala, C; Alfred, M; Andrieux, V; Apadula, N; Asano, H; Azmoun, B; Babintsev, V; Bandara, N S; Barish, K N; Bathe, S; Bazilevsky, A; Beaumier, M; Belmont, R; Berdnikov, A; Berdnikov, Y; Blau, D S; Bok, J S; Brooks, M L; Bryslawskyj, J; Bumazhnov, V; Campbell, S; Cervantes, R; Chi, C Y; Chiu, M; Choi, I J; Choi, J B; Citron, Z; Cronin, N; Csanád, M; Csörgő, T; Danley, T W; Daugherity, M S; David, G; DeBlasio, K; Dehmelt, K; Denisov, A; Deshpande, A; Desmond, E J; Dion, A; Dixit, D; Do, J H; Drees, A; Drees, K A; Durham, J M; Durum, A; Enokizono, A; En'yo, H; Esumi, S; Fadem, B; Fan, W; Feege, N; Fields, D E; Finger, M; Finger, M; Jr., \\,; Fokin, S L; Frantz, J E; Franz, A; Frawley, A D; Fukuda, Y; Gal, C; Gallus, P; Garg, P; Ge, H; Giordano, F; Goto, Y; Grau, N; Greene, S V; Perdekamp, M Grosse; Gunji, T; Guragain, H; Hachiya, T; Haggerty, J S; Hahn, K I; Hamagaki, H; Hamilton, H F; Han, S Y; Hanks, J; Hasegawa, S; Haseler, T O S; He, X; Hemmick, T K; Hill, J C; Hill, K; Hollis, R S; Homma, K; Hong, B; Hoshino, T; Hotvedt, N; Huang, J; Huang, S; Imai, K; Inaba, M; Iordanova, A; Isenhower, D; Ivanishchev, D; Jacak, B V; Jezghani, M; Jiang, X; Johnson, B M; Jouan, D; Jumper, D S; Kang, J H; Kapukchyan, D; Karthas, E; Kawall, D; Kazantsev, A V; Khachatryan, V; Khanzadeev, A; Kim, C; Kim, E -J; Kim, M; Kincses, D; Kistenev, E; Klatsky, J; Kline, P; Koblesky, T; Kotov, D; Kudo, S; Kurita, K; Kwon, Y; Lajoie, J G; Lebedev, A; Lee, S; Leitch, M J; Leung, Y H; Li, X; Lim, S H; Liu, M X; Loggins, V-R; Lovasz, K; Lynch, D; Majoros, T; Makdisi, Y I; Makek, M; Manko, V I; Mannel, E; McCumber, M; McGaughey, P L; McGlinchey, D; McKinney, C; Mendoza, M; Mignerey, A C; Milov, A; Mishra, D K; Mitchell, J T; Mitsuka, G; Miyasaka, S; Mizuno, S; Montuenga, P; Moon, T; Morrison, D P; Murakami, T; Murata, J; Nagai, K; Nagashima, K; Nagashima, T; Nagle, J L; Nagy, M I; Nakagawa, I; Nakano, K; Nattrass, C; Niida, T; Nouicer, R; Novák, T; Novitzky, N; Nyanin, A S; O'Brien, E; Ogilvie, C A; Koop, J D Orjuela; Osborn, J D; Oskarsson, A; Ottino, G J; Ozawa, K; Pantuev, V; Papavassiliou, V; Park, J S; Park, S; Pate, S F; Patel, M; Perepelitsa, D V; Perera, G D N; Peressounko, D Yu; PerezLara, C E; Perry, J; Petti, R; Phipps, M; Pinkenburg, C; Pisani, R P; Purschke, M L; Read, K F; Reynolds, D; Riabov, V; Riabov, Y; Rinn, T; Rolnick, S D; Rosati, M; Rowan, Z; Safonov, A S; Sakaguchi, T; Sako, H; Samsonov, V; Sarsour, M; Sato, S; Schaefer, B; Schmoll, B K; Sedgwick, K; Seidl, R; Sen, A; Seto, R; Sexton, A; Sharma, D; Shein, I; Shibata, T -A; Shigaki, K; Shimomura, M; Shioya, T; Shukla, P; Sickles, A; Silva, C L; Silvermyr, D; Singh, B K; Singh, C P; Singh, V; Slunečka, M; Snowball, M; Soltz, R A; Sondheim, W E; Sorensen, S P; Sourikova, I V; Stankus, P W; Stoll, S P; Sugitate, T; Sukhanov, A; Sumita, T; Sun, J; Sziklai, J; Tanida, K; Tannenbaum, M J; Tarafdar, S; Tarnai, G; Tieulent, R; Timilsina, A; Todoroki, T; Tomášek, M; Towell, C L; Towell, R S; Tserruya, I; Ueda, Y; Ujvari, B; van Hecke, H W; Velkovska, J; Virius, M; Vrba, V; Vukman, N; Wang, X R; Watanabe, Y S; Wong, C P; Woody, C L; Xu, C; Xu, Q; Xue, L; Yalcin, S; Yamaguchi, Y L; Yamamoto, H; Yanovich, A; Yoo, J H; Yoon, I; Yu, H; Yushmanov, I E; Zajc, W A; Zelenski, A; Zou, L

    2016-01-01

    We present the first measurements of long-range angular correlations and the transverse momentum dependence of elliptic flow $v_2$ in high-multiplicity $p$$+$Au collisions at $\\sqrt{s_{_{NN}}}=200$ GeV. A comparison of these results with previous measurements in high-multiplicity $d$$+$Au and $^3{\\rm He}$$+$Au collisions demonstrates a relation between $v_2$ and the initial collision eccentricity $\\varepsilon_2$, suggesting that the observed momentum-space azimuthal anisotropies in these small systems have a collective origin and reflect the initial geometry. Good agreement is observed between the measured $v_2$ and hydrodynamic calculations for all systems, and an argument disfavoring theoretical explanations based on momentum-space domain correlations is presented. The set of measurements presented here allows us to leverage the distinct intrinsic geometry of each of these systems to distinguish between different theoretical descriptions of the long-range correlations observed in small collision systems.

  5. Measurement of long-range correlations in pp collisions characterized by presence of a Z-boson

    CERN Document Server

    Milov, Alexander; The ATLAS collaboration

    2017-01-01

    Recent measurements of correlations between two particles separated in pesudorapidity and azimuthal angles have shown striking similarities between results obtained in pp, and in p+A and A+A collision systems. In pp collision system, unlike in the p+A and A+A systems, the strength of the correlations quantified by the anisotropy parameter $v_2$ does not show any dependence on the charged-particle multiplicity. Recent theoretical models suggest that this can be due to lack of correlation between the charged-particle multiplicity and the impact parameter of the pp collision. An independent handle on the impact parameter can be obtained by requiring the presence of a hard-scattering process in the collision. This talk presents the first measurement of two-particle correlations in pp collisions with a Z boson identified via its dimuon decay channel. The analysis uses ATLAS data recorded under nominal pp luminosities, and a procedure to correct for contribution of the tracks coming from pileup vertices is used. Th...

  6. Base deformation of full metal-jacketed rifle bullets as a measure of impact velocity and range of fire.

    Science.gov (United States)

    Haag, Lucien C

    2015-03-01

    Full metal-jacketed rifle bullets with lead cores and open bases can experience deformation of their cylindrical shapes as they yaw during the penetration of soft tissues. The amount of deformation depends upon the strength of the bullet and the velocity in soft tissue when they go into yaw. The yaw behavior of a bullet in soft tissue depends upon its design (length, ogive shape, ogive length, center of gravity, and pre-impact stability) as it penetrates soft tissue. The yaw characteristics of common spitzer-type military rifle bullets are relatively well known and quite reproducible when fired into suitable soft tissue simulants. This, in turn, results in a relationship between the amount of deformation of the bullet's shank and impact velocity with soft tissue. The specific relationship between impact velocity and bullet deformation must be worked out through empirical testing, but this relationship can be of critical importance in determining impact velocity, which, in turn, relates to range of fire.

  7. Simpson's Method of Discs for Measurement of Echocardiographic End?Diastolic and End?Systolic Left Ventricular Volumes: Breed?Specific Reference Ranges in Boxer Dogs

    OpenAIRE

    Smets, P.; Daminet, S.; Wess, G

    2013-01-01

    Background Boxer dogs are predisposed to congenital and adult onset cardiac diseases. Breed?specific reference values for M?mode and Doppler echocardiographic measurements previously have been established. Left ventricular (LV) end?systolic (ESV) and end?diastolic volumes (EDV) can be measured by M?mode or two?dimensional methods, such as Simpson's method of discs (SMOD). Reference ranges for SMOD?derived LV volumes are lacking. Objectives To determine reference intervals for EDV and ESV in B...

  8. This week?s Citation Classic: 'Stickel, L. F. A comparison of certain methods of measuring ranges of small mammals. J. Mammalogy 35: 1-15, 1954.'

    Science.gov (United States)

    Stickel, L.F.

    1986-01-01

    During my first employment as a junior biologist conducting food habits analyses at the Patuxent Research Refuge (now Patuxent Wildlife Research Center) of the US Fish and Wildlife Service, the first station director, Arnold L. Nelson, gave each staff biologist the opportunity to spend a little time conducting field studies on the 2,600-acre research area. These studies were to help in ecological evaluation of the area, but also, no doubt, functioned as a morale builder for biologists daily engaged in difficult, demanding and confining laboratory work. I undertook to measure the population density of small mammals in different habitats. The state-of-the-art methods recommended to me and prevalent in the literature worried me, especially after preliminary field work. Reading the classic, paper by W.H. Burt [Terrioriality and home range concepts as applied to mammals. J. Mammalogy 24:346-352, 1943] was a turning point for me in seeing that knowledge of home-range size was the key to measuring population density. My first papers employed these concepts in field evaluations. However, they could give-only limited attention to the question of how home ranges could be measured. Furthermore, the importance of knowledge of the home range to habitat evaluation and to understanding animal behavior was becoming increasingly apparent. Advocacy of many different methods of measuring home ranges appeared in the literature. It did not seem possible to evaluate them objectively. It occurred to me that artificial populations could be used to help in understanding the mechanisms of measuring home ranges. The effects of random trap-visiting, bias toward central traps, trap-spacing, range shape, and other factors could be considered. So grids of traps were inked onto oversize graph paper, and simulated ranges were cut from plastic to be tossed as randomly as possible on the trap-grids. It was a slow, laborious job. Analysis showed that random captures in artificial populations produced

  9. Measurements of Surface-Layer Turbulence in a Wide Norwegian Fjord Using Synchronized Long-Range Doppler Wind Lidars

    Directory of Open Access Journals (Sweden)

    Etienne Cheynet

    2017-09-01

    Full Text Available Three synchronized pulsed Doppler wind lidars were deployed from May 2016 to June 2016 on the shores of a wide Norwegian fjord called Bjørnafjord to study the wind characteristics at the proposed location of a planned bridge. The purpose was to investigate the potential of using lidars to gather information on turbulence characteristics in the middle of a wide fjord. The study includes the analysis of the single-point and two-point statistics of wind turbulence, which are of major interest to estimate dynamic wind loads on structures. The horizontal wind components were measured by the intersecting scanning beams, along a line located 25 m above the sea surface, at scanning distances up to 4.6 k m . For a mean wind velocity above 8 m · s - 1 , the recorded turbulence intensity was below 0.06 on average. Even though the along-beam spatial averaging leads to an underestimated turbulence intensity, such a value indicates a roughness length much lower than provided in the European standard EN 1991-1-4:2005. The normalized spectrum of the along-wind component was compared to the one provided by the Norwegian Petroleum Industry Standard and the Norwegian Handbook for bridge design N400. A good overall agreement was observed for wave-numbers below 0 . 02 / m . The along-beam spatial averaging in the adopted set-up prevented a more detailed comparison at larger wave-numbers, which challenges the study of wind turbulence at scanning distances of several kilometres. The results presented illustrate the need to complement lidar data with point-measurement to reduce the uncertainties linked to the atmospheric stability and the spatial averaging of the lidar probe volume. The measured lateral coherence was associated with a decay coefficient larger than expected for the along-wind component, with a value around 21 for a mean wind velocity bounded between 10 m · s - 1 and 14 m · s - 1 , which may be related to a stable atmospheric stratification.

  10. Gastric emptying in rats following administration of a range of different fats measured as acetaminophen concentration in plasma

    DEFF Research Database (Denmark)

    Porsgaard, Trine; Straarup, Ellen Marie; Høy, Carl-Erik

    2003-01-01

    butter as well as different structured lipids containing decanoic acid (10:0) and long-chain n-3 polyunsaturated fatty acids of marine origin. Overall, these fats had wide variations in fatty acid compositions and triacylglycerol structures. Results: No statistically significant differences were observed...... of this fat as compared with the other fats, because similar weights of fat were administered. Conclusion: The gastric emptying of fat was not influenced by fatty acid composition and triacylglycerol structure of the fats administered.......Aim: To investigate the gastric emptying upon administration of ten different fats in order to determine whether major differences in fatty acid profiles resulted in differences in gastric emptying. Methods: Gastric emptying was measured as the appearance of acetaminophen in plasma which represents...

  11. Static and Dynamic Accuracy of an Innovative Miniaturized Wearable Platform for Short Range Distance Measurements for Human Movement Applications

    Science.gov (United States)

    Cereatti, Andrea; Comotti, Daniele; Caldara, Michele; Della Croce, Ugo

    2017-01-01

    Magneto-inertial measurement units (MIMU) are a suitable solution to assess human motor performance both indoors and outdoors. However, relevant quantities such as step width and base of support, which play an important role in gait stability, cannot be directly measured using MIMU alone. To overcome this limitation, we developed a wearable platform specifically designed for human movement analysis applications, which integrates a MIMU and an Infrared Time-of-Flight proximity sensor (IR-ToF), allowing for the estimate of inter-object distance. We proposed a thorough testing protocol for evaluating the IR-ToF sensor performances under experimental conditions resembling those encountered during gait. In particular, we tested the sensor performance for different (i) target colors; (ii) sensor-target distances (up to 200 mm) and (iii) sensor-target angles of incidence (AoI) (up to 60∘). Both static and dynamic conditions were analyzed. A pendulum, simulating the oscillation of a human leg, was used to generate highly repeatable oscillations with a maximum angular velocity of 6 rad/s. Results showed that the IR-ToF proximity sensor was not sensitive to variations of both distance and target color (except for black). Conversely, a relationship between error magnitude and AoI values was found. For AoI equal to 0∘, the IR-ToF sensor performed equally well both in static and dynamic acquisitions with a distance mean absolute error technology represents a valuable alternative solution in terms of accuracy, sampling frequency, dimension and power consumption, compared to existing technologies. PMID:28672803

  12. Extending the frequency range of free-field reciprocity calibration of measurement microphones to frequencies up to 150 kHz

    DEFF Research Database (Denmark)

    Barrera Figueroa, Salvador; Torras Rosell, Antoni; Jacobsen, Finn

    2013-01-01

    Measurement microphones are typically calibrated in a free field at frequencies up to 50 kHz. This is a sufficiently high frequency for the most sound measurement applications related with noise assessment. However, other applications such as the measurement of noise emitted by ultrasound cleaning...... machines and failure detection in aeronautic structures require that the sensitivity of the microphone is known at frequencies up to 150 kHz. Another area of particular interest is the investigation of the perception mechanisms of ultrasound. In any of these applications, it is of fundamental importance...... to establish a well-defined traceability chain to support the measurement results. In order to extend the frequency range of free-field calibration the measurement system and measurement methods must undergo a series of changes and adaptations including the type of excitation signal, techniques for eliminating...

  13. Práticas do CMMI® como regras de negócio CMMI® practices as business rules

    Directory of Open Access Journals (Sweden)

    Gisele P. Morgado

    2007-08-01

    Full Text Available A busca pela qualidade de software leva à adoção de boas práticas no processo do desenvolvimento de software, como as práticas especificadas pelo modelo de maturidade do CMMI. A implantação do CMMI, entretanto, constitui um processo penoso e demorado. Além disso, a qualidade deste processo afeta diretamente os resultados obtidos. Este artigo explora a possibilidade de formalização das práticas do CMMI através do seu mapeamento para Regras de Negócio. A viabilidade desta proposta é estudada através do mapeamento da parte do CMMI relativa à área Gerência de Requisitos. As vantagens desta abordagem encontram-se tanto no aumento da qualidade do processo de certificação/auditoria do CMMI, quanto na melhoria da qualidade do sistema de informação que apóia o processo de desenvolvimento de software.The search for software quality results in the adoption of best practices in the software development process, such as the practices specified by the CMMI maturity model. However, the CMMI implementation constitutes a difficult and slow process. Besides, the quality of such a process directly affects the results obtained. This article explores the possibility of formalizing the CMMI practices via their mapping into Business Rules. This proposal viability was studied through the mapping of the CMMI part that concerns the Requirements Management area. This approach implies in an improvement of the CMMI certification/audit process and of the information system that supports the software development process.

  14. Attivitá fisica extra-scolastica negli adolescenti: il ruolo dello stato socio-economico delle famiglie

    Directory of Open Access Journals (Sweden)

    G. Capelli

    2003-05-01

    Full Text Available

    Obiettivi: l’associazione fra stato socio-economico (SES ed attività fisica è poco indagata. Obiettivo del presente studio è quello di valutare la relazione tra attività fisica extra-scolastica di adolescenti scolarizzati e lo SES della famiglia di provenienza.

    Metodi: l’indagine ha previsto la somministrazione nel corso dell’anno scolastico 2002-2003 di un apposito questionario anonimo autocompilato, già validato in uno studio pilota, ad un campione di studenti delle scuole medie inferiori del Lazio (province di Roma, Frosinone e Latina.

    Risultati: hanno partecipato allo studio 1486 studenti di cui 756 maschi (50.9% e 730 femmine (49.1%. L’età dei partecipanti varia fra gli 11 ed i 15 anni (età mediana 12 anni. Il 72.7% degli studenti dichiara di svolgere attività fisica al di fuori della scuola. Il livello di istruzione dei genitori e la loro attività lavorativa sembrano avere un peso notevole sui determinanti dell’attività fisica negli studenti. Infatti, svolgono prevalentemente attività fisica extra-scolastica i figli di genitori manager/libero professionisti (OR = 3.29 e con un elevato livello educativo (OR = 10.38 per i figli di genitori laureati.

    Conclusioni: i risultati confermano quanto la situazione socio-economica delle famiglie sia in netta relazione con l’attività fisico-sportiva dei giovani. Tali risultati potranno essere utili per gli operatori scolastici e gli amministratori nell’ispirare e realizzare azioni volte a diminuire il divario esistente fra i giovani che hanno le possibilità economiche e svolgono attività sportiva extra-scolastica e quelli che, invece, appartenendo a famiglie svantaggiate, hanno minore accesso a tali attività.

  15. Static and Dynamic Accuracy of an Innovative Miniaturized Wearable Platform for Short Range Distance Measurements for Human Movement Applications

    Directory of Open Access Journals (Sweden)

    Stefano Bertuletti

    2017-06-01

    Full Text Available Magneto-inertial measurement units (MIMU are a suitable solution to assess human motor performance both indoors and outdoors. However, relevant quantities such as step width and base of support, which play an important role in gait stability, cannot be directly measured using MIMU alone. To overcome this limitation, we developed a wearable platform specifically designed for human movement analysis applications, which integrates a MIMU and an Infrared Time-of-Flight proximity sensor (IR-ToF, allowing for the estimate of inter-object distance. We proposed a thorough testing protocol for evaluating the IR-ToF sensor performances under experimental conditions resembling those encountered during gait. In particular, we tested the sensor performance for different (i target colors; (ii sensor-target distances (up to 200 mm and (iii sensor-target angles of incidence (AoI (up to 60 ∘ . Both static and dynamic conditions were analyzed. A pendulum, simulating the oscillation of a human leg, was used to generate highly repeatable oscillations with a maximum angular velocity of 6 rad/s. Results showed that the IR-ToF proximity sensor was not sensitive to variations of both distance and target color (except for black. Conversely, a relationship between error magnitude and AoI values was found. For AoI equal to 0 ∘ , the IR-ToF sensor performed equally well both in static and dynamic acquisitions with a distance mean absolute error <1.5 mm. Errors increased up to 3.6 mm (static and 11.9 mm (dynamic for AoI equal to ± 30 ∘ , and up to 7.8 mm (static and 25.6 mm (dynamic for AoI equal to ± 60 ∘ . In addition, the wearable platform was used during a preliminary experiment for the estimation of the inter-foot distance on a single healthy subject while walking. In conclusion, the combination of magneto-inertial unit and IR-ToF technology represents a valuable alternative solution in terms of accuracy, sampling frequency, dimension and power consumption

  16. Contribution of long-range transported aerosols to aerosol optical and physical properties: 3-year measurements at Gosan, Korea

    Science.gov (United States)

    Heo, J.; Kim, S. W.; Kim, J. H.; Ogren, J. A.; Yoon, S. C.

    2015-12-01

    Recently, more attentions have been paid to air quality in East Asia due to the enhanced loading of atmospheric pollutants related to rapid industrialization. Gosan Climate Observatory (GCO), Korea is regarded as an ideal site to study the transport of atmospheric pollutants because it is frequently influenced by various airmasses from China, Korea, Japan and Pacific Ocean. In order to understand aerosol optical and physical properties according to airmass transport routes, three-year (2012-2014) continuous measurements of aerosol scattering/absorption coefficient and number size distribution were analyzed, together with 48-hour backward trajectory calculations. The averaged aerosol absorption (σa) and scattering coefficient (σs) for airmasses transported from North China (NC; 36% of all trajectories) were 6.65 Mm-1 and 94.72 Mm-1 at 550 nm wavelength, respectively, which were similar to those for stagnant airmasses (ST; 22% of all trajectories; σa: 6.26 Mm-1, σs: 93.99 Mm-1). The highest values of σa (7.03 Mm-1) and σs (108.34 Mm-1) were observed when airmasses were traveled from South China (SC; 11% of all trajectories). σa and σs for airmasses from Korean Peninsula (KP; 7% of all trajectories) and Pacific Ocean (PO; 14% of all trajectories; in parenthesis) were 5.63 (2.76) Mm-1 and 73.63 (50.93) Mm-1, respectively. Compared to other airmasses, the higher values of Scattering Angstrom Exponent (SAE) for ST (1.65) is thought to be the build-up of anthropogenic fine particulate pollutants. The Absorption Angstrom Exponent (AAE) was estimated to be 1.32 for NC airmass and 1.02 for SC airmass. Over the study period, 130 days of total 557 days were identified as new particle formation and growth event (NPF) from Scanning Mobility Particle Sizer (SMPS) measurements by Cyclostationary Empirical Orthogonal Function (CSEOF) approach. Especially, 55.4% (72 days) of total 130 NPF days were found when a cold and dry airmass comes from NC after passing the frontal

  17. Dynamic emergence of the mesenchymal CD44(pos)CD24(neg/low) phenotype in HER2-gene amplified breast cancer cells with de novo resistance to trastuzumab (Herceptin).

    Science.gov (United States)

    Oliveras-Ferraros, Cristina; Vazquez-Martin, Alejandro; Martin-Castillo, Begoña; Cufí, Silvia; Del Barco, Sonia; Lopez-Bonet, Eugeni; Brunet, Joan; Menendez, Javier A

    2010-06-18

    Evidence is mounting that the occurrence of the CD44(pos)/CD24(neg/low) cell population, which contains potential breast cancer (BC) stem cells, could explain BC clinical resistance to HER2-targeted therapies. We investigated whether de novo refractoriness to the anti-HER2 monoclonal antibody trastuzumab (Tzb; Herceptin) may relate to the dynamic regulation of the mesenchymal CD44(pos)/CD24(neg/low) phenotype in HER2-positive BC. We observed that the subpopulation of Tzb-refractory JIMT-1 BC cells exhibiting CD44(pos)/CD24(neg/low)-surface markers switched with time. Low-passage JIMT-1 cell cultures were found to spontaneously contain approximately 10% of cells bearing the CD44(pos)/CD24(neg/low) immunophenotype. Late-passage (>60) JIMT-1 cultures accumulated approximately 80% of CD44(pos)/CD24(neg/low) cells and closely resembled the CD44(pos)/CD24(neg/low)-enriched ( approximately 85%) cell population constitutively occurring in HER2-negative MDA-MB-231 mesenchymal BC cells. Dynamic expression of mesenchymal markers was not limited to CD44/CD24 because high-passages of JIMT-1 cells exhibited also reduced expression of the HER2 protein and over-secretion of pro-invasive/metastatic chemokines and metalloproteases. Accordingly, late-passage JIMT-1 cells displayed an exacerbated migratogenic phenotype in plastic, collagen, and fibronectin substrates. Intrinsic genetic plasticity to efficiently drive the emergence of the CD44(pos)/CD24(neg/low) mesenchymal phenotype may account for de novo resistance to HER2 targeting therapies in basal-like BC carrying HER2 gene amplification. Copyright (c) 2010 Elsevier Inc. All rights reserved.

  18. A perspective on reagent diversity and non-covalent binding of reactive carbonyl species (RCS) and effector reagents in nonenzymatic glycation (NEG): Mechanistic considerations and implications for future research

    Science.gov (United States)

    Rodnick, Kenneth J.; Holman, R. W.; Ropski, Pamela S.; Huang, Mingdong; Swislocki, Arthur L. M.

    2017-06-01

    This perspective focuses on illustrating the underappreciated connections between reactive carbonyl species (RCS), initial binding in the nonenzymatic glycation (NEG) process, and nonenzymatic covalent protein modification (here termed NECPM). While glucose is the central species involved in NEG, recent studies indicate that the initially-bound glucose species in the NEG of human hemoglobin (HbA) and human serum albumin (HSA) are non-RCS ring-closed isomers. The ring-opened glucose, an RCS structure that reacts in the NEG process, is most likely generated from previously-bound ring-closed isomers undergoing concerted acid/base reactions while bound to protein. The generation of the glucose RCS can involve concomitantly-bound physiological species (e.g., inorganic phosphate, water, etc.); here termed effector reagents. Extant NEG schemes do not account for these recent findings. In addition, effector reagent reactions with glucose in the serum and erythrocyte cytosol can generate RCS (e.g., glyoxal, glyceraldehyde, etc.). Recent research has shown that these RCS covalently modify proteins in vivo via NECPM mechanisms. A general scheme that reflects both the reagent and mechanistic diversity that can lead to NEG and NECPM is presented here. A perspective that accounts for the relationships between RCS, NEG, and NECPM can facilitate the understanding of site selectivity, may help explain overall glycation rates, and may have implications for the clinical assessment/control of diabetes mellitus. In view of this perspective, concentrations of ribose, fructose, Pi, bicarbonate, counter ions, and the resulting RCS generated within intracellular and extracellular compartments may be of importance and of clinical relevance. Future research is also proposed.

  19. Alanine-EPR dosimetry for measurements of ionizing radiation absorbed doses in the range 0.5-10 kGy

    CERN Document Server

    Peimel-Stuglik, Z

    2001-01-01

    The usefulness of two, easy accessible alanine dosimeters (ALANPOL from IChTJ and foil dosimeter from Gamma Service, Radeberg, Germany) to radiation dose measurement in the range of 0.5-10 kGy, were investigated. In both cases, the result of the test was positive. The foil dosemeter from Gamma Service is recommended for dose distribution measurements in fantoms or products, ALANPOL - for routine measurements. The EPR-alanine method based on the described dosimeters can be successfully used, among others, in the technology of radiation protection of food.

  20. Reliability of ankle dorsiflexion passive range of motion measurements obtained using a hand-held goniometer and Biodex dynamometer in stroke patients.

    Science.gov (United States)

    Jung, In-Gui; Yu, Il-Young; Kim, Soo-Yong; Lee, Dong-Kyu; Oh, Jae-Seop

    2015-06-01

    [Purpose] This study investigated the reliability of ankle dorsiflexion passive range of motion (DF-PROM) measurements obtained using a goniometer and Biodex dynamometer in stroke patients. [Subjects] Fifteen stroke patients participated in this study. [Methods] Ankle DF-PROM was assessed using a goniometer and Biodex dynamometer. Ankle DF-PROM was measured during two sessions with 7 days between tests. Intraclass correlation coefficient, standard error of measurement, and minimal detectable change values were used to assess the reliability of measurements obtained using both instruments. [Results] The intra-rater reliability for ankle DF-PROM using the goniometer was moderate and good for the two raters, while using the Biodex dynamometer, it was good for both raters. Inter-rater reliability using the goniometer was moderate; using the Biodex, it was good. [Conclusion] Both intra- and inter-reliability measurements of ankle DF-PROM were higher using a Biodex dynamometer than with a goniometer.

  1. Indoor biological pollution; L'inquinamento ambientale negli ambienti indoor

    Energy Technology Data Exchange (ETDEWEB)

    Bressa, G. [Padua Univ., Padua (Italy)

    2000-06-01

    Inside buildings - besides the umpteen toxic substances emanating from materials and appliances used daily for the most assorted activities - there are may be a number of different pathogenic micro-organisms able to cause diseases and respiratory system infections. Indoor pollution caused by biological agents may be due not only to living microorganisms, but also to dead ones or to the produce of their metabolism as well as to allergens. The most efficient precautionary measure against biological agents is to ventilate the rooms one lives in. In case of air-conditioning, it's good rule to keep air pipes dry and clean, renewing filters at regular intervals in order to avoid fungi and bacteria from settling in. [Italian] All'interno degli edifici oltre alle innumerevoli sostanze tossiche che si sprigionano da materiali e apparecchiature impiegate nelle piu' svariate attivita' quotidiane vi possono essere diversi microorganismi patogeni in grado di provocare malattie ed infezioni dell'apparato respiratorio. L'inquinamento indoor da agenti biologici puo' essere dovuto non solo ai microorganismi viventi ma anche a quelli morti, oppure ai prodotti del loro metabolismo ed anche agli allergeni. Il mezzo di prevenzione piu' efficace nel confronto degli agenti biologici consiste nel ricambio di aria all'interno dei locali in cui si vive. In presenza di impianti di climatizzazione, una buona regola e' quella di mantenere pulite e asciutte le condotte dell'aria, sostituendo periodicamente i filtri per evitare l'insediamento di funghi e batteri.

  2. Signature of biased range in the non-dynamical Chern-Simons modified gravity and its measurements with satellite-satellite tracking missions: theoretical studies

    Energy Technology Data Exchange (ETDEWEB)

    Qiang, Li-E [Chang' an University, Department of Geophysics, College of Geology Engineering and Geomatics, Xi' an (China); Xu, Peng [Chinese Academy of Sciences, Academy of Mathematics and Systems Science, Beijing (China)

    2015-08-15

    Having great accuracy in the range and range rate measurements, the GRACE mission and the planed GRACE follow on mission can in principle be employed to place strong constraints on certain relativistic gravitational theories. In this paper, we work out the range observable of the non-dynamical Chern-Simons modified gravity for the satellite-to-satellite tracking (SST) measurements. We find out that a characteristic time accumulating range signal appears in non-dynamical Chern-Simons gravity, which has no analogue found in the standard parity-preserving metric theories of gravity. The magnitude of this Chern-Simons range signal will reach a few times of χ cm for each free flight of these SST missions, here χ is the dimensionless post-Newtonian parameter of the non-dynamical Chern-Simons theory. Therefore, with the 12 years data of the GRACE mission, one expects that the mass scale M{sub CS} = (4ℎc)/(χa) of the non-dynamical Chern-Simons gravity could be constrained to be larger than 1.9 x 10.9 eV. For the GRACE FO mission that scheduled to be launched in 2017, the much stronger bound that M{sub CS} ≥ 5 x 10{sup -7} eV is expected. (orig.)

  3. A three-line lateral flow assay strip for the measurement of C-reactive protein covering a broad physiological concentration range in human sera.

    Science.gov (United States)

    Oh, Young Kyoung; Joung, Hyou-Arm; Han, Hyung Soo; Suk, Ho-Jun; Kim, Min-Gon

    2014-11-15

    The lateral flow assay (LFA) strip sensor possesses many advantages as a diagnostic device, including the capabilities of rapid, one-step assay performance, and high throughput production. A major limitation of the sensor, however, is its difficulty in measuring a broad concentration range of target proteins, including C-reactive protein (CRP), due to the "hook effect." In this study, we report the use of a three-line LFA strip sensor, adding an antigen line to the conventional two-line LFA sensor, for detecting CRP within a broad concentration range in human sera. We introduced an antigen line between test and control lines in the LFA sensor. The antigen line was formed by dispensing a CRP antibody solution followed by a CRP solution in nitrocellulose membrane. All other conditions were identical to those applied to the conventional LFA strip sensor. The CRP level in test samples was generated by data processing from the intensities of three lines. The strip sensor measured a linear detection range of CRP concentration from 1 ng/mL to 500 μg/mL within 10 min, with a calculated detection range of 0.69 ng/mL-1.02 mg/mL. Using the developed three-line LFA sensor, 50 clinical samples were measured at a detection range of 0.4-84.7 μg/mL. This novel and easy-to-use CRP sensor can be a useful tool for rapid, sensitive, and cost-effective detection of a broad physiological concentration range of CRP capabilities that are vital for various diagnostic applications. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Wavelength dispersion measurement of electro-optic coefficients in the range of 520 to 930 nm in rubidium titanyl phosphate using spectral interferometry.

    Science.gov (United States)

    Gobert, Olivier; Fedorov, Nikita; Mennerat, Gabriel; Lupinski, Dominique; Guillaumet, Delphine; Perdrix, Michel; Bourgeade, Antoine; Comte, Michel

    2012-02-10

    Rubidium titanyl phosphate (RTP) is widely used for electro-optical applications at low switching voltages. RTP is nonhygroscopic and does not induce piezoelectric ringing up to the megahertz range. It has large electro-optic (EO) coefficients and a high damage threshold. We present here the EO coefficient wavelength dispersion measurements in the [550,950] nm spectral range using a method based on spectral interferometry. These data are necessary for, among other things, a quantitative modelization of an EO carrier-envelope phase shifter.

  5. Tools used in mineral exploration for measuring the conductivity and the resistivity in drillholes and on drill core: observations on their range of sensitivity

    Science.gov (United States)

    Parry, Devon; Smith, Richard S.; Mahmoodi, Omid

    2016-07-01

    A study has been undertaken to acquire conductivity data using the EM39 low-induction-number conductivity tool. Measurements were taken in three holes in the Sudbury, Ontario, area: at Victoria in the south-west part of the Sudbury structure; at Levack, in the north range; and at the Lady Violet deposit near Copper Cliff. These data were compared with pre-existing data acquired using four other tools and measurements taken on core extracted from the holes. The four tools are the DGI galvanic downhole resistivity tool, the IFG downhole conductivity tool, and the handheld KT-10 and GDD meters. The comparison shows that each tool has a finite range of sensitivity. The resistivity tool used by DGI Geoscience is sensitive to conductivities primarily in the range 0.01 to 100 mS/m; the EM39 tool is sensitive to conductivities in the range of ~30 mS/m to 3000 mS/m and the IFG tool to conductivities greater than 30 mS/m. In the sub-ranges where the ranges of two instruments overlap, one might expect a good correlation between the measurements derived from the two tools. However, this is not always the case, as the instruments can have a different volume of sensitivity: the EM39 has a coil separation of 50 cm and will see material greater than 20 cm away from the hole; whereas the IFG conductivity tool seems to have a smaller spatial scale of sensitivity due to its 10 cm coil size. The handheld instruments used to log the conductivity of the core are sensitive to more conductive material (greater than ~1 S/m). The scale of the sensors of these handheld instruments is a few cm, so they are focussing on a very local estimate. The spatial characteristics of the handheld instruments are similar to the IFG tool, so there is a reasonable linear correlation between the conductivities derived from these three different instruments. However, the slopes are not unity; for example, the GDD instrument gives values three times greater than the KT-10. When selecting tools for measuring

  6. A study to compare the reliability of composite finger flexion with goniometry for measurement of range of motion in the hand.

    Science.gov (United States)

    Ellis, Bridget; Bruton, Anne

    2002-08-01

    To establish the intra- and inter-rater reliability of composite finger flexion (CFF), and to compare this with goniometry. Fifty-one physiotherapists and occupational therapists took part in the study. The hand of a normal subject was splinted in three different positions. Using a goniometer and a ruler alternately, each therapist measured both the proximal interphalangeal joint and CFF of three digits, following a standardized protocol. This process was repeated three times. Eighteen NHS hospital sites in the UK. The two measurement methods produced different ranges and standard deviations for each digit. The repeatability coefficient shows that repeated intra-rater goniometric measures fall within 4-5 degrees of each other 95% of the time. Inter-rater goniometric measures fall within 7-9 degrees. Repeated intra-rater CFF measures fall within 5-6 mm of each other, whereas inter-rater fall within 7-9 mm. The influence of occupation, experience in hand therapy, years of practice and routine use were found to have no effect on reliability. Scaling of the two methods of measurement allowed comparison between them to be made. CFF and goniometry are equally reliable when comparing inter-rater reliability, but goniometry displays less variability than composite finger flexion for intra-rater measurements. In this study involving a subject with normal joints, goniometry is more reliable than CFF when only one measurer is involved. However, CFF may be a useful alternative where multiple joint measures are required, or when goniometry is impracticable.

  7. Processo de inclusão digital como indutor de estratégia para a sustentabilidade dos negócios

    Directory of Open Access Journals (Sweden)

    Silvia Gattai

    2007-06-01

    Full Text Available As estratégias empresariais têm como principal função garantir a sustentabilidade das organizações, o que depende, entre outros fatores, a médio e longo prazos, da existência de mercados que sejam capazes economicamente de absorver seus produtos. Por outro lado, a concentração de riqueza em pequenos grupos econômicos e o aumento da pobreza em muitos países geram riscos para a perpetuidade dos negócios. As empresas, nesse contexto, necessitam de estratégias que considerem o desenvolvimento estrutural dos países onde atuam, e essa compreensão passa pelo entendimento de sua participação na governança das cidades nas quais possuem suas unidades de negócios, condição fundamental nesse processo. Tal visão é necessária para o desenvolvimento do meio no qual a empresa se insere e, conseqüentemente, à sustentabilidade do negócio. O objetivo deste artigo é buscar compreender o papel de processo de desenvolvimento social, promovido pela empresa, como indutor de estratégias empresariais sustentáveis. Nesse sentido, o artigo aborda os conceitos de prospecção de cenários, ações estratégicas, desenvolvimento empresarial e a agregação de valor social ao ambiente no qual as organizações estão inseridas. A título de exemplificação, relata projeto de inclusão digital envolvendo cadeia de distribuição de empresa cimenteira brasileira de grande porte e o analisa à luz dos conceitos acima referenciados.

  8. Changes in natural Foxp3(+Treg but not mucosally-imprinted CD62L(negCD38(+Foxp3(+Treg in the circulation of celiac disease patients.

    Directory of Open Access Journals (Sweden)

    Marieke A van Leeuwen

    Full Text Available BACKGROUND: Celiac disease (CD is an intestinal inflammation driven by gluten-reactive CD4(+ T cells. Due to lack of selective markers it has not been determined whether defects in inducible regulatory T cell (Treg differentiation are associated with CD. This is of importance as changes in numbers of induced Treg could be indicative of defects in mucosal tolerance development in CD. Recently, we have shown that, after encounter of retinoic acid during differentiation, circulating gut-imprinted T cells express CD62L(negCD38(+. Using this new phenotype, we now determined whether alterations occur in the frequency of natural CD62L(+Foxp3(+ Treg or mucosally-imprinted CD62L(negCD38(+Foxp3(+ Treg in peripheral blood of CD patients. In particular, we compared pediatric CD, aiming to select for disease at onset, with adult CD. METHODS: Cell surface markers, intracellular Foxp3 and Helios were determined by flow cytometry. Foxp3 expression was also detected by immunohistochemistry in duodenal tissue of CD patients. RESULTS: In children, the percentages of peripheral blood CD4(+Foxp3(+ Treg were comparable between CD patients and healthy age-matched controls. Differentiation between natural and mucosally-imprinted Treg on the basis of CD62L and CD38 did not uncover differences in Foxp3. In adult patients on gluten-free diet and in refractory CD increased percentages of circulating natural CD62L(+Foxp3(+ Treg, but normal mucosally-imprinted CD62L(negCD38(+Foxp3(+ Treg frequencies were observed. CONCLUSIONS: Our data exclude that significant numeric deficiency of mucosally-imprinted or natural Foxp3(+ Treg explains exuberant effector responses in CD. Changes in natural Foxp3(+ Treg occur in a subset of adult patients on a gluten-free diet and in refractory CD patients.

  9. Bovine peripheral blood WC1+ and WC1neg γδ T lymphocytes modulate monocyte-derived macrophage effector functions during in vitro Mycobacterium avium subspecies paratuberculosis infection.

    Science.gov (United States)

    Baquero, Monica M; Plattner, Brandon L

    2017-05-01

    The importance of bovine γδ T lymphocytes during anti-mycobacterial immunity is recognized; however, the role of major subsets of γδ T lymphocytes (WC1+ and WC1neg) in this process remains unclear. We investigated how WC1+ and WC1neg γδ T lymphocyte subsets of calves modulate monocyte-derived macrophage (MDM) functions during Map infection in vitro. To achieve this, Map-infected or uninfected MDMs from young calves were co-cultured with autologous WC1+ or WC1neg γδ T lymphocytes. Our data indicate that WC1+ and WC1neg γδ T lymphocytes of young calves modulate effector functions of MDMs with respect to Map killing, CD11b and MHC-II expression. We observed differences in IFN-γ production and CD25 expression on γδ T lymphocyte subsets, as well as MDM expression of CD1b when in contact with WC1neg γδ T lymphocytes. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. O modelo de negócio da Starbucks e a sua aplicação ao caso português

    OpenAIRE

    Pereira, Feliciano Pires

    2009-01-01

    Relatório de Projecto / Mestrado em Gestão / Códigos do JEL Classification System: M10, M16. Classificações do JEL Classification System: Gestão, Estratégia Empresarial. O caso em estudo insere-se no âmbito da estratégia empresarial e descreve o modelo de negócio da Starbucks, um dos gigantes mundiais no fornecimento, torrefacção e retalho do mercado do café de alta qualidade. A empresa, criada em Seattle em 1971, teve um crescimento exponencial nos últimos anos, conseguindo em...

  11. Valor das capacidades de TI para o negócio: análise de desempenho multinível nas organizações brasileiras

    Directory of Open Access Journals (Sweden)

    Deyvison de Lima Oliveira

    Full Text Available Resumo: Considerando as demandas da Teoria Baseada em Recursos (TBR e da literatura de Sistemas de Informação (SI quanto à captação do valor da TI em multiníveis de desempenho do negócio, este artigo objetiva identificar em que medida as Capacidades de TI impactam diretamente o Desempenho em nível de Processos e indiretamente o Desempenho em nível de Firma. Adota-se como método a survey, aplicada em três fases de pesquisa: i. Survey pré-teste – com pesquisadores representantes das áreas de TI e de negócios; ii. Survey piloto – com profissionais de TI e de negócios; e iii. Survey completa – aplicada a gestores de TI e de negócios em organizações brasileiras de grande porte, conforme ranking de 2012 das maiores empresas do Brasil. Por meio da Modelagem de Equações Estruturais, o modelo de medida é definido no estudo piloto e confirmado no estudo completo – sendo testadas as hipóteses de pesquisa no modelo estrutural. Os resultados evidenciam que as Capacidades de TI impactam positivamente o Desempenho de Processos e este impacta o Desempenho em nível da Firma. Adicionalmente, constata-se o impacto indireto das Capacidades de TI no Desempenho da Firma, configurando-se a mediação parcial pelo Desempenho de Processos. Testa-se a moderação de quatro variáveis (tamanho da firma, tempo de atuação, dinamismo do setor e indústria na relação entre Capacidades de TI e Desempenho de Processos, obtendo-se resultados nulos para ambas as moderadoras. As contribuições teóricas da pesquisa, as limitações e oportunidades de investigação constam na discussão e nas conclusões do artigo.

  12. Indicadores de Sustentabilidade em Simulações de Negócios: uma proposição no contexto do jogo de empresas SEE

    OpenAIRE

    Paulo da Costa Lopes; Rafael Bonrim de Souza

    2010-01-01

    O artigo foi desenvolvido com o objetivo de propor a inserção de indicadores de sustentabilidade em simulações de negócios. Para tanto, foi realizada uma pesquisa básica, qualitativa, descritiva, bibliográfica e documental. Foi elaborado um levantamento teórico-metodológico sobre jogos de empresas e sustentabilidade, foi introduzida a Global Reporting Initiative (GRI) como promotora de um padrão de comunicação global em ações empresariais sustentáveis, e apresentou-se o jogo de empresas SEE (...

  13. Impactos da internet na indústria farmacêutica: novo modelo de negócios na economia da informação

    OpenAIRE

    Andrade, Marcelo Gelamos de

    2010-01-01

    Trata dos efeitos da Internet sobre as organizações, abordando as características da chamada Nova Economia da Informação. Focando a Indústria Farmacêutica, analisa os fundamentos que devem ser considerados pelas na revisão de seus modelos estratégicos e a proposição de um novo modelo de negócios para a Indústria Farmacêutica tomando em conta os impactos da Internet.

  14. Reliability of measuring the passive range of shoulder horizontal adduction using a smartphone in the supine versus the side-lying position.

    Science.gov (United States)

    Lim, Jin-Yong; Kim, Tae-Ho; Lee, Jung-Seok

    2015-10-01

    [Purpose] The purpose of this study was to compare the reliability of the measurement of the passive range of motion (PROM) of shoulder horizontal adduction (SHA) measurements using a smartphone for the assessment posterior shoulder tightness (PST) between the side-lying and supine test positions. [Subjects and Methods] Forty-seven subjects (mean ± age, 24.9 ± 3.5 years) without shoulder pathology were included in this study. Intra-rater and inter-rater reliabilities were determined using intraclass correlation coefficients. The SHA PROM of each subject's dominant shoulder was measured using a smartphone by two investigators in two positions: the standard supine position, and a side-lying position on the tested side. [Results] The intra-rater reliability of the supine measurements was fair to good (ICC3,1 = 0.72-0.89), and for the side-lying measurements was excellent (ICC3,1 = 0.95-0.97). The inter-rater reliability of the supine measurements was fair (ICC2,2 = 0.79) and for the side-lying measurements was excellent (ICC2,2 = 0.94). [Conclusion] These results suggest that for healthy subjects, measurements of SHA using smartphones in the side-lying position has superior intra-rater and inter-rater reliabilities compared to the standard supine position.

  15. Design of a sun tracker for the automatic measurement of spectral irradiance and construction of an irradiance database in the 330-1100 nm range

    Energy Technology Data Exchange (ETDEWEB)

    Canada, J.; Maj, A. [Departamento de Termodinamica Aplicada, Universidad Politecnica de Valencia, Camino de Vera, s/n. 46022 Valencia (Spain); Utrillas, M.P.; Martinez-Lozano, J.A.; Pedros, R.; Gomez-Amo, J.L. [Departamento de Fisica de la Tierra y Termodinamica, Facultat de Fisica, Universitat de Valencia, 46100 Burjassot (Valencia) (Spain)

    2007-10-15

    An automatic global and direct solar spectral irradiance system has been designed based on two LICOR spectro radiometers equipped with fibre optics and remote cosine sensors. To measure direct irradiance a sun tracker based on step motors has been developed. The whole system is autonomous and works continuously. From the measurements provided by this system a spectral irradiance database in the 330-1100 nm range has been created. This database contains normal direct and global horizontal irradiances as well as diffuse irradiance on a horizontal plane, together with total atmospheric optical thickness and aerosol optical depth. (author)

  16. Accurate and stable equal-pressure measurements of water vapor transmission rate reaching the 10-6 g m-2 day-1 range

    Science.gov (United States)

    Nakano, Yoichiro; Yanase, Takashi; Nagahama, Taro; Yoshida, Hajime; Shimada, Toshihiro

    2016-10-01

    The water vapor transmission rate (WVTR) of a gas barrier coating is a critically important parameter for flexible organic device packaging, but its accurate measurement without mechanical stress to ultrathin films has been a significant challenge in instrumental analysis. At the current stage, no reliable results have been reported in the range of 10-6 g m-2 day-1 that is required for organic light emitting diodes (OLEDs). In this article, we describe a solution for this difficult, but important measurement, involving enhanced sensitivity by a cold trap, stabilized temperature system, pumped sealing and calibration by a standard conductance element.

  17. Using the Rasch Model to Develop a Measure of Participation Capturing the Full Range of Participation Characteristics for the Patients with Hand Injuries.

    Science.gov (United States)

    Farzad, Maryam; Layeghi, Fereydoun; Hosseini, Ali; Whiteneck, Gale; Asgari, Ali

    2017-08-01

    Objective  The purpose of this paper was to report on the first step in the development of a new instrument to measure participation including the full range of its characteristics. Methods  The 30-item participation behavior questionnaire (PBQ) was developed from four main sources (a literature review of the theatrical basis of participation, available participation measures, and interviews with patients and experts about participation). Item selection and the reliability and validity of the measure were explored using Rasch measurement modeling for analysis. Participants  A total of 404 individuals referred to rehabilitation after hand, wrist, or upper extremity surgery to reduce impairment from trauma, at least 2 months post-injury. Results  An initial pool of 100 items; reflecting 14 characteristics of participation was initially reduced to 91 items after review by 15 participation experts and then further reduced to 30 items by three rounds of Rasch analysis removing misfitting items. The final PBQ has a person reliability of 0.91 with separation of 3.22, indicating it can reliably differentiate four levels of participation. There are no misfitting items and the instrument is unidimensional. All 14 characteristics of participation were retained in the PBQ, and none of the 30 items refer specifically to upper extremity issues. Conclusion  The 30 participation behavior items of the PBQ show promise of being a psychometrically sound measure of participation. Further research is needed to validate the PBQ in samples of people with a range of other disabilities.

  18. Development of a quartz tuning-fork-based force sensor for measurements in the tens of nanoNewton force range during nanomanipulation experiments

    Energy Technology Data Exchange (ETDEWEB)

    Oiko, V. T. A., E-mail: oiko@ifi.unicamp.br; Rodrigues, V.; Ugarte, D. [Instituto de Física “Gleb Wataghin,” Univ. Estadual de Campinas (UNICAMP), Campinas 13083-859 (Brazil); Martins, B. V. C. [Department of Physics, University of Alberta, Edmonton, Alberta T6G 2R3 (Canada); Silva, P. C. [Laboratório Nacional de Nanotecnologia, CNPEM, Campinas 13083-970 (Brazil)

    2014-03-15

    Understanding the mechanical properties of nanoscale systems requires new experimental and theoretical tools. In particular, force sensors compatible with nanomechanical testing experiments and with sensitivity in the nN range are required. Here, we report the development and testing of a tuning-fork-based force sensor for in situ nanomanipulation experiments inside a scanning electron microscope. The sensor uses a very simple design for the electronics and it allows the direct and quantitative force measurement in the 1–100 nN force range. The sensor response is initially calibrated against a nN range force standard, as, for example, a calibrated Atomic Force Microscopy cantilever; subsequently, applied force values can be directly derived using only the electric signals generated by the tuning fork. Using a homemade nanomanipulator, the quantitative force sensor has been used to analyze the mechanical deformation of multi-walled carbon nanotube bundles, where we analyzed forces in the 5–40 nN range, measured with an error bar of a few nN.

  19. Influence of temporal noise on the skin blood flow measurements performed by cooled thermal imaging camera: limit possibilities within each physiological frequency range

    Science.gov (United States)

    Sagaidachnyi, A. A.; Volkov, I. U.; Fomin, A. V.

    2016-04-01

    This paper describes limit possibilities of modern cooled thermal imaging cameras as a tool for estimation of blood flow oscillations at the surface of living body. Skin temperature oscillations, as we assumed, are a consequence of the blood flow oscillations. We considered the temperature sensitivity 0.01-0.02 °C as a typical for the most of modern cooled long wave thermal imaging cameras. Fourier filter used to investigate the temperature signal separately within endothelial, neurogenic, myogenic, respiratory and cardiac frequency ranges. The level of temporal noise has been estimated during measurements of no living body with stabilized temperature ~ 24°C. The level of temperature oscillations has been calculated for the group of healthy subjects within each frequency range. Thus, we were able to determine signal-to-noise ratio within frequency band [0.001, 1] Hz. As a result, we determine that skin temperature oscillations measured by thermal imaging camera with sensitivity 0.02°C have the upper frequency limit ~ 0.2 Hz. In other words, within the respiratory and cardiac frequency ranges of blood flow oscillations the noise level exceeds signal one, and temperature measurements at the skin surface are practically useless. The endothelial, neurogenic and myogenic components of the temperature oscillations contain ~98% of the total spectral power of the signal. We have plot the empirical extrapolated curve of sensitivity of thermal imaging camera vs. frequency of the temperature oscillations. The data analysis shows that measurements of skin temperature oscillations within respiratory and cardiac ranges require the temperature sensitivity at least ~ 0.01°C and 0.001°C, respectively.

  20. Modification of streaming potential by precipitation of calcite in a sand-water system: laboratory measurements pH range from 4 to 12

    OpenAIRE

    Guichet, Xavier; Jouniaux, Laurence; Catel, Nicole

    2006-01-01

    The definitive version is available at www.blackwell-synergy.com; We acknowledge the Geophysical Journal International, the Royal Astronomical Society and Blackwell Publishing. Full bibliographic reference is : Guichet, X., L. Jouniaux, and N. Catel, Modification of streaming potential by precipitation of calcite in a sand-water system: laboratory measurements in the pH range from 4 to 12, Geophysical Journal International, 166, 445-460, doi:10.1111/j.1365-246X.2006.02922.x, 2006; Spontaneous...

  1. Dissemination of ultraprecise measurements in radiometry and remote sensing within 100-3500K temperature range based on blackbody sources developed in VNIIOFI

    Science.gov (United States)

    Sapritsky, Victor I.; Ogarev, Sergey A.; Khlevnoy, Boris B.; Samoylov, Mikhail L.; Khromchenko, Vladimir B.; Morozova, Svetlana P.

    2002-12-01

    The large variety of high-precision unique blackbody sources: those operating at fixed temperatures provided by phase transitions of metals and metal-carbon eutectics, and variable-temperature ones had been designed in VNIIOFI for high-precision radiometry, radiation thermometry and spaceborne remote sensing within a 100 to 3500K temperature range. Paper reviews the blackbodies (BBs) ranged to low, middle and high temperatures, and describes spectral radiance and irradiance calibration facilities on the base of these BBs in IR and V-UV spectral ranges. The latest investigations of high-temperature fix-points based on metal-carbon eutectics Re-C (2748K) demonstrated an excellent reproducibility of freezing plateau (up to 0.01% in terms of radiation temperature) between series of measurements/crucibles, and about 0.003% within a sample measurement session, i.e. better than 100mK. Further Re-C (spectral irradiance measurements) and TiC-C (3057° C) eutectics are being investigated for use as high-stable radiance/irradiance sources above the conventionally assigned values of temperatures of ITS-90.

  2. Systematic errors in the measurement of adsorption isotherms by frontal analysis Impact of the choice of column hold-up volume, range and density of the data points.

    Science.gov (United States)

    Gritti, Fabrice; Guiochon, Georges

    2005-12-02

    Besides the accuracy and the precision of the measurements of the data points, several important parameters affect the accuracy of the adsorption isotherms that are derived from the data acquired by frontal analysis (FA). The influence of these parameters is discussed. First, the effects of the width of the concentration range within which the adsorption data are measured and of the distribution of the data points in this range are investigated. Systematic elimination of parts of the data points before the calculation of the nonlinear regression of the data to the model illustrates the importance of the numbers of data points (1) within the linear range and (2) at high concentrations. The influence of the inaccuracy of the estimate of the column hold-up volume on each adsorption data point, on the selection of the isotherm model, and on the best estimates of the adsorption isotherm parameters is also stressed. Depending on the method used to measure it, the hold-up time can vary by more than 10%. The high concentration part of the adsorption isotherm is particularly sensitive to errors made on t(0,exp) and as a result, when the isotherm follows bi-Langmuir isotherm behavior, the equilibrium constant of the low-energy sites may change by a factor 2. This study shows that the agreement between calculated and experimental overloaded band profiles is a necessary condition to validate the choice of an adsorption model and the calculation of its numerical parameters but that this condition is not sufficient.

  3. An adiabatic calorimeter for heat capacity measurements of polyurethane foam with blowing agent of HFC245fa in the temperature range 60-290K

    Energy Technology Data Exchange (ETDEWEB)

    Yang, C.G.; Xu, L.; Zhang, L.Q.; Chen, N. [Institute of Refrigeration and Cryogenics, Shanghai Jiao Tong University, Shanghai 200030 (China)

    2006-06-15

    In order to meet the urgent need of heat insulating materials used under low temperature in the area of aerospace, a new polyurethane (PU) foam with HFC245fa as blowing agent was developed. In this paper, the heat capacity in the temperature range of 60-290K of the new material was measured through an automated adiabatic calorimeter, which was composed of a heat insulation system, a power measuring system, a vacuum pumping system and a cooling system. The sample cell of the calorimeter was equipped with a miniature platinum thermometer surrounded by two adiabatic shields and housed in a high vacuum can. The temperature differences among the sample cell and the inner and outer adiabatic shields could be adjusted automatically to less than 0.05K, all which ensure there was no heat exchange between the sample and surroundings. Under these conditions, the mathematical formulation of the sample with the physical model was given. Through measuring the heat capacity of {alpha}-Al{sub 2}O{sub 3}, which is a standard reference material, a relatively high reliability with a deviation of +/-2.5% of this adiabatic calorimeter was shown compared with the standard data. The results indicate that the newly developed PU foam has a higher heat capacity compared with other heat insulating materials, and there is no obvious sign of any phase transition or thermal anomaly in the entire temperature range. That is to say, the material is thermodynamically stable when used in the low temperature range. (author)

  4. An adiabatic calorimeter for heat capacity measurements of polyurethane foam with blowing agent of HFC245fa in the temperature range 60-290 K

    Energy Technology Data Exchange (ETDEWEB)

    Yang, C.G. [Institute of Refrigeration and Cryogenics, Shanghai Jiao Tong University, Shanghai 200030 (China)]. E-mail: chunguang_yang@sjtu.edu.cn; Xu, L. [Institute of Refrigeration and Cryogenics, Shanghai Jiao Tong University, Shanghai 200030 (China); Zhang, L.Q. [Institute of Refrigeration and Cryogenics, Shanghai Jiao Tong University, Shanghai 200030 (China); Chen, N. [Institute of Refrigeration and Cryogenics, Shanghai Jiao Tong University, Shanghai 200030 (China)

    2006-06-15

    In order to meet the urgent need of heat insulating materials used under low temperature in the area of aerospace, a new PU foam with HFC245fa as blowing agent was developed. In this paper, the heat capacity in the temperature range of 60-290 K of the new material was measured through an automated adiabatic calorimeter, which was composed of a heat insulation system, a power measuring system, a vacuum pumping system and a cooling system. The sample cell of the calorimeter was equipped with a miniature platinum thermometer surrounded by two adiabatic shields and housed in a high vacuum can. The temperature differences among the sample cell and the inner and outer adiabatic shields could be adjusted automatically to less than 0.05 K, all which ensure there was no heat exchange between the sample and surroundings. Under these conditions, the mathematical formulation of the sample with the physical model was given. Through measuring the heat capacity of {alpha}-Al{sub 2}O{sub 3}, which is a standard reference material, a relatively high reliability with a deviation of {+-}2.5% of this adiabatic calorimeter was shown compared with the standard data. The results indicate that the newly developed PU foam has a higher heat capacity compared with other heat insulating materials, and there is no obvious sign of any phase transition or thermal anomaly in the entire temperature range. That is to say, the material is thermodynamically stable when used in the low temperature range.

  5. The application of multi-baseline digital close-range photogrammetry in three-dimensional imaging and measurement of dental casts.

    Science.gov (United States)

    Fu, Xiaoming; Peng, Chun; Li, Zan; Liu, Shan; Tan, Minmin; Song, Jinlin

    2017-01-01

    To explore a new technique for reconstructing and measuring three-dimensional (3D) models of orthodontic plaster casts using multi-baseline digital close-range photogrammetry (MBDCRP) with a single-lens reflex camera. Thirty sets of orthodontic plaster casts that do not exhibit severe horizontal overlap (>2 mm) between any two teeth were recorded by a single-lens reflex camera with 72 pictures taken in different directions. The 3D models of these casts were reconstructed and measured using the open source software MeshLab. These parameters, including mesio-distal crown diameter, arch width, and arch perimeter, were recorded six times on both the 3D digital models and on plaster casts by two examiners. Statistical analysis was carried out using the Bland-Altman method to measure agreement between the novel method and the traditional calliper method by calculating the differences between mean values. The average differences between the measurements of the photogrammetric 3D models and the plaster casts were 0.011-0.402mm. The mean differences between measurements obtained by the photogrammetric 3D models and the dental casts were not significant except for the lower arch perimeter (P>0.05), and all the differences were regarded as clinically acceptable (<0.5 mm). Measurements obtained by MBDCRP are compared well with those obtained from plaster casts, indicating that MBDCRP is an alternate way to store and measure dental plaster casts without severe horizontal overlap between any two teeth.

  6. Adoção das IFRS para operações de combinações de negócios nas demonstrações financeiras consolidadas de empresas listadas na Espanha e Reino Unido

    OpenAIRE

    Cristal, Carisa Santos Portela

    2009-01-01

    Operações de combinação de negócios representam uma estratégia de crescimento para muitas companhias ao redor do mundo. No Brasil observa-se um grande aumento no volume de operações de combinação de negócios nos últimos anos. A edição da Lei n° 11.638/07 vem propiciar condições para que o Brasil caminhe para a convergência às normas internacionais, tornando obrigatória a adoção dessas normas, incluídas aquelas concernentes às operações de combinações de negócios. Esse estudo tem por objetivo:...

  7. Impacts of long-range transports of PM10 on air quality in Gwangju, South Korea using satellite and in-situ measured data

    Science.gov (United States)

    Park, R.; Han, K.; Song, C.; Kang, Y.; Jung, W.; Ahan, S.

    2013-12-01

    To investigate the impact of long-range transported particular matter on the city of Gwangju which is one of metropolitan cities in the South Korea and is located in the southwestern part of the Korean peninsula, the PM10 concentrations measured at six measurement sites in Gwangju area were used. A decadal trend (2002-2011) of PM10 was analyzed and then the monthly and daily variations of PM10 for the years of 2002, 2003, 2006, and 2011 were investigated. The events of long-range transport were selected from peaks of daily PM10 and were evaluated through 72-hours backward trajectory analysis using NOAA HYbrid Single-Particle Lagrangian Integrated Trajectory (HYSPLIT) model. In addition, the events were evaluated using Total Ozone Mapping Spectrometer (TOMS)-retrieved AI (Aerosol Index), Moderate Resolution Imaging Spectrometer (MODIS) and Geostationary Ocean Color Imager (GOCI)-retrieved Aerosol Optical Depth (AOD). Then the daily PM10 influenced by the long-range transport was filtered and the monthly variations calculated from the filtered daily PM10 and the daily PM10 influenced by the long-range transport were compared. For the year of 2002, up to ~50% of the PM10 concentration was influenced by Asian dust in March and April, respectively. In contrast, for the year of 2003, the impact of LRT on the PM10 concentrations were relatively small in the Gwangju areas. The monthly variations and annual mean values for 2002, 2003, 2006, and 2011, calculated from the filtered daily PM10, were similar and therefore, the annual variations of PM10 in Gwangju could be mainly affected by the long-range transport.

  8. Local complex permittivity measurements of porcine skin tissue in the frequency range from 1 GHz to 15 GHz by evanescent microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Kleismit, Richard A; Kozlowski, Gregory; Foy, Brent D [Department of Physics, Wright State University, 3640 Col. Glenn Hwy, Dayton, OH 45435-0001 (United States); Hull, Barbara E [Department of Biological Sciences, Wright State University, 3640 Col. Glenn Hwy, Dayton, OH 45435-0001 (United States); Kazimierczuk, Marian [Department of Electrical Engineering, Wright State University, 3640 Col. Glenn Hwy, Dayton, OH 45435-0001 (United States)], E-mail: richard.kleismit@wright.edu

    2009-02-07

    The near-field evanescent microwave microscope is based on a coaxial transmission line resonator with a silver plated tungsten tip protruding through an end-wall aperture. The sensor is used to measure the local dielectric properties of porcine skin in the frequency range from 1 GHz to 15 GHz. The dielectric property of the skin within the near field of the tip frustrates the electric field and measurably changes the transmission line's resonant frequency and quality factor (Q). The shift of the resonator's frequency and Q is measured as a function of tip-sample separation, and a quantitative relationship between the real and imaginary parts of the local dielectric constant using the method of images is established. The associated changes in quality factor image scans of subsurface tissue structure and dielectric properties of skin surface lesions are presented.

  9. Spectral Aerosol Extinction (SpEx): A New Instrument for In situ Ambient Aerosol Extinction Measurements Across the UV/Visible Wavelength Range

    Science.gov (United States)

    Jordan, C. E.; Anderson, B. E.; Beyersdorf, A. J.; Corr, C. A.; Dibb, J. E.; Greenslade, M. E.; Martin, R. F.; Moore, R. H.; Scheuer, E.; Shook, M. A.; hide

    2015-01-01

    We introduce a new instrument for the measurement of in situ ambient aerosol extinction over the 300-700 nm wavelength range, the Spectral Aerosol Extinction (SpEx) instrument. This measurement capability is envisioned to complement existing in situ instrumentation, allowing for simultaneous measurement of the evolution of aerosol optical, chemical, and physical characteristics in the ambient environment. In this work, a detailed description of the instrument is provided along with characterization tests performed in the laboratory. Measured spectra of NO2 and polystyrene latex spheres agreed well with theoretical calculations. Good agreement was also found with simultaneous aerosol extinction measurements at 450, 530, and 630 nm using CAPS PMex instruments in a series of 22 tests including non-absorbing compounds, dusts, soot, and black and brown carbon analogs. SpEx can more accurately distinguish the presence of brown carbon from other absorbing aerosol due to its 300 nm lower wavelength limit compared to measurements limited to visible wavelengths. In addition, the spectra obtained by SpEx carry more information than can be conveyed by a simple power law fit that is typically defined by the use of Angstrom Exponents. Future improvements aim at lowering detection limits and ruggedizing the instrument for mobile operation.

  10. Simulating a Range of Regolith Porosities in the Lab: An Investigation into the Effects of Porosity on Spectral Measurements of Olivine

    Science.gov (United States)

    Evans, R.; Bowles, N. E.; Donaldson Hanna, K. L.

    2016-12-01

    Our current understanding of the composition of planetary bodies primarily comes from remote sensing spectroscopic observations. The interpretation of spectroscopic data requires analogue mineral spectra measured in the lab under appropriate environmental conditions.This is particularly true in the thermal infrared. At these wavelengths porosity, particle size, and near-surface environmental conditions have significant effects on the wavelength position and spectral contrast of diagnostic features. To isolate the effects due to porosity, diffuse reflectance measurements were made from 2.5 to 25 µm of a fine particulate San Carlos olivine sample (University of Oxford's Simulated Lunar Environment Chamber. When measured in diffuse reflectance, we find that as the porosity increases the Christiansen feature (CF, a reflection minimum or emissivity maximum near 8 µm) shifts to longer wavelengths. In the thermal emissivity spectral measurements, we see no discernible shift in the CF position as the porosity changes. In both reflectance and emission the strength and position of the transparency feature (the spectral region from 11 to 13 µm where volume scattering dominates) behaves as expected, as the strength of the feature increases with porosity. In reflectance the relative strength of the reststrahlen bands (RB) were not observed to change systematically with porosity. In this presentation we provide details of our experimental set-up, the range of porosities simulated in the lab, and our spectroscopic results. These new measurements place important constraints for interpreting remote sensing measurements of planetary bodies.

  11. Intraobserver and interobserver reliability of a method to measure ankle plantar-flexion range of motion in the hook-lying position.

    Science.gov (United States)

    Nunes, Guilherme S; Bayer, Gabriela S; M R da Costa, Letícia; de Noronha, Marcos

    2012-10-11

    Physical therapists often have to measure ankle range of motion (ROM) to decide on intervention and investigate improvements. The most common method of measurement is goniometry, but it has been questioned due to its unsatisfactory levels of reliability. To investigate the intraobserver and interobserver reliability of a new method of measuring plantar-flexion ROM. Prospective and descriptive. Laboratory. 20 healthy participants (12 women and 8 men). Ankle plantar flexion was measured by 3 observers (A, B, and C) with 3 methods (goniometry, measurement in hook-lying position [MHP], and static-image analysis [SIA]). Observer A was the most experienced therapist, and C, the least. MHP was performed with the participant in the supine position, knees flexed, and first and fifth metatarsals in contact with the treatment table. SIA was recorded and analyzed in the same position. Goniometry was performed with participant seated, lower legs unsupported, and axis positioned on the lateral malleolus. For the interobserver analysis, the ICC2,1 was high for the MHP (.88), high for SIA (.87), and moderate for goniometry (.57). For the intraobserver analysis, the ICC2,1 was high or very high for MHP (.91-.92), high for SIA (.79-.83), and low to moderate for goniometry (.18-.60). MHP is inexpensive, fast, and more reliable than goniometry for measuring plantar-flexion ROM.

  12. Measurements of long-range near-side angular correlations in $\\sqrt{s_{\\text{NN}}}=5$TeV proton-lead collisions in the forward region

    CERN Document Server

    Aaij, Roel; Adeva, Bernardo; Adinolfi, Marco; Affolder, Anthony; Ajaltouni, Ziad; Akar, Simon; Albrecht, Johannes; Alessio, Federico; Alexander, Michael; Ali, Suvayu; Alkhazov, Georgy; Alvarez Cartelle, Paula; Alves Jr, Antonio Augusto; Amato, Sandra; Amerio, Silvia; Amhis, Yasmine; An, Liupan; Anderlini, Lucio; Anderson, Jonathan; Andreassi, Guido; Andreotti, Mirco; Andrews, Jason; Appleby, Robert; Aquines Gutierrez, Osvaldo; Archilli, Flavio; d'Argent, Philippe; Artamonov, Alexander; Artuso, Marina; Aslanides, Elie; Auriemma, Giulio; Baalouch, Marouen; Bachmann, Sebastian; Back, John; Badalov, Alexey; Baesso, Clarissa; Baldini, Wander; Barlow, Roger; Barschel, Colin; Barsuk, Sergey; Barter, William; Batozskaya, Varvara; Battista, Vincenzo; Bay, Aurelio; Beaucourt, Leo; Beddow, John; Bedeschi, Franco; Bediaga, Ignacio; Bel, Lennaert; Bellee, Violaine; Belloli, Nicoletta; Belyaev, Ivan; Ben-Haim, Eli; Bencivenni, Giovanni; Benson, Sean; Benton, Jack; Berezhnoy, Alexander; Bernet, Roland; Bertolin, Alessandro; Bettler, Marc-Olivier; van Beuzekom, Martinus; Bien, Alexander; Bifani, Simone; Billoir, Pierre; Bird, Thomas; Birnkraut, Alex; Bizzeti, Andrea; Blake, Thomas; Blanc, Frédéric; Blouw, Johan; Blusk, Steven; Bocci, Valerio; Bondar, Alexander; Bondar, Nikolay; Bonivento, Walter; Borghi, Silvia; Borsato, Martino; Bowcock, Themistocles; Bowen, Espen Eie; Bozzi, Concezio; Braun, Svende; Britsch, Markward; Britton, Thomas; Brodzicka, Jolanta; Brook, Nicholas; Buchanan, Emma; Burr, Christopher; Bursche, Albert; Buytaert, Jan; Cadeddu, Sandro; Calabrese, Roberto; Calvi, Marta; Calvo Gomez, Miriam; Campana, Pierluigi; Campora Perez, Daniel; Capriotti, Lorenzo; Carbone, Angelo; Carboni, Giovanni; Cardinale, Roberta; Cardini, Alessandro; Carniti, Paolo; Carson, Laurence; Carvalho Akiba, Kazuyoshi; Casse, Gianluigi; Cassina, Lorenzo; Castillo Garcia, Lucia; Cattaneo, Marco; Cauet, Christophe; Cavallero, Giovanni; Cenci, Riccardo; Charles, Matthew; Charpentier, Philippe; Chefdeville, Maximilien; Chen, Shanzhen; Cheung, Shu-Faye; Chiapolini, Nicola; Chrzaszcz, Marcin; Cid Vidal, Xabier; Ciezarek, Gregory; Clarke, Peter; Clemencic, Marco; Cliff, Harry; Closier, Joel; Coco, Victor; Cogan, Julien; Cogneras, Eric; Cogoni, Violetta; Cojocariu, Lucian; Collazuol, Gianmaria; Collins, Paula; Comerma-Montells, Albert; Contu, Andrea; Cook, Andrew; Coombes, Matthew; Coquereau, Samuel; Corti, Gloria; Corvo, Marco; Couturier, Benjamin; Cowan, Greig; Craik, Daniel Charles; Crocombe, Andrew; Cruz Torres, Melissa Maria; Cunliffe, Samuel; Currie, Robert; D'Ambrosio, Carmelo; Dall'Occo, Elena; Dalseno, Jeremy; David, Pieter; Davis, Adam; De Aguiar Francisco, Oscar; De Bruyn, Kristof; De Capua, Stefano; De Cian, Michel; De Miranda, Jussara; De Paula, Leandro; De Simone, Patrizia; Dean, Cameron Thomas; Decamp, Daniel; Deckenhoff, Mirko; Del Buono, Luigi; Déléage, Nicolas; Demmer, Moritz; Derkach, Denis; Deschamps, Olivier; Dettori, Francesco; Dey, Biplab; Di Canto, Angelo; Di Ruscio, Francesco; Dijkstra, Hans; Donleavy, Stephanie; Dordei, Francesca; Dorigo, Mirco; Dosil Suárez, Alvaro; Dossett, David; Dovbnya, Anatoliy; Dreimanis, Karlis; Dufour, Laurent; Dujany, Giulio; Dupertuis, Frederic; Durante, Paolo; Dzhelyadin, Rustem; Dziurda, Agnieszka; Dzyuba, Alexey; Easo, Sajan; Egede, Ulrik; Egorychev, Victor; Eidelman, Semen; Eisenhardt, Stephan; Eitschberger, Ulrich; Ekelhof, Robert; Eklund, Lars; El Rifai, Ibrahim; Elsasser, Christian; Ely, Scott; Esen, Sevda; Evans, Hannah Mary; Evans, Timothy; Falabella, Antonio; Färber, Christian; Farley, Nathanael; Farry, Stephen; Fay, Robert; Ferguson, Dianne; Fernandez Albor, Victor; Ferrari, Fabio; Ferreira Rodrigues, Fernando; Ferro-Luzzi, Massimiliano; Filippov, Sergey; Fiore, Marco; Fiorini, Massimiliano; Firlej, Miroslaw; Fitzpatrick, Conor; Fiutowski, Tomasz; Fohl, Klaus; Fol, Philip; Fontana, Marianna; Fontanelli, Flavio; Forshaw, Dean Charles; Forty, Roger; Frank, Markus; Frei, Christoph; Frosini, Maddalena; Fu, Jinlin; Furfaro, Emiliano; Gallas Torreira, Abraham; Galli, Domenico; Gallorini, Stefano; Gambetta, Silvia; Gandelman, Miriam; Gandini, Paolo; Gao, Yuanning; García Pardiñas, Julián; Garra Tico, Jordi; Garrido, Lluis; Gascon, David; Gaspar, Clara; Gauld, Rhorry; Gavardi, Laura; Gazzoni, Giulio; Gerick, David; Gersabeck, Evelina; Gersabeck, Marco; Gershon, Timothy; Ghez, Philippe; Gianì, Sebastiana; Gibson, Valerie; Girard, Olivier Göran; Giubega, Lavinia-Helena; Gligorov, V.V.; Göbel, Carla; Golubkov, Dmitry; Golutvin, Andrey; Gomes, Alvaro; Gotti, Claudio; Grabalosa Gándara, Marc; Graciani Diaz, Ricardo; Granado Cardoso, Luis Alberto; Graugés, Eugeni; Graverini, Elena; Graziani, Giacomo; Grecu, Alexandru; Greening, Edward; Gregson, Sam; Griffith, Peter; Grillo, Lucia; Grünberg, Oliver; Gui, Bin; Gushchin, Evgeny; Guz, Yury; Gys, Thierry; Hadavizadeh, Thomas; Hadjivasiliou, Christos; Haefeli, Guido; Haen, Christophe; Haines, Susan; Hall, Samuel; Hamilton, Brian; Han, Xiaoxue; Hansmann-Menzemer, Stephanie; Harnew, Neville; Harnew, Samuel; Harrison, Jonathan; He, Jibo; Head, Timothy; Heijne, Veerle; Heister, Arno; Hennessy, Karol; Henrard, Pierre; Henry, Louis; Hernando Morata, Jose Angel; van Herwijnen, Eric; Heß, Miriam; Hicheur, Adlène; Hill, Donal; Hoballah, Mostafa; Hombach, Christoph; Hulsbergen, Wouter; Humair, Thibaud; Hussain, Nazim; Hutchcroft, David; Hynds, Daniel; Idzik, Marek; Ilten, Philip; Jacobsson, Richard; Jaeger, Andreas; Jalocha, Pawel; Jans, Eddy; Jawahery, Abolhassan; Jing, Fanfan; John, Malcolm; Johnson, Daniel; Jones, Christopher; Joram, Christian; Jost, Beat; Jurik, Nathan; Kandybei, Sergii; Kanso, Walaa; Karacson, Matthias; Karbach, Moritz; Karodia, Sarah; Kecke, Matthieu; Kelsey, Matthew; Kenyon, Ian; Kenzie, Matthew; Ketel, Tjeerd; Khairullin, Egor; Khanji, Basem; Khurewathanakul, Chitsanu; Kirn, Thomas; Klaver, Suzanne; Klimaszewski, Konrad; Kochebina, Olga; Kolpin, Michael; Komarov, Ilya; Koopman, Rose; Koppenburg, Patrick; Kozeiha, Mohamad; Kravchuk, Leonid; Kreplin, Katharina; Kreps, Michal; Krocker, Georg; Krokovny, Pavel; Kruse, Florian; Krzemien, Wojciech; Kucewicz, Wojciech; Kucharczyk, Marcin; Kudryavtsev, Vasily; Kuonen, Axel Kevin; Kurek, Krzysztof; Kvaratskheliya, Tengiz; Lacarrere, Daniel; Lafferty, George; Lai, Adriano; Lambert, Dean; Lanfranchi, Gaia; Langenbruch, Christoph; Langhans, Benedikt; Latham, Thomas; Lazzeroni, Cristina; Le Gac, Renaud; van Leerdam, Jeroen; Lees, Jean-Pierre; Lefèvre, Regis; Leflat, Alexander; Lefrançois, Jacques; Lemos Cid, Edgar; Leroy, Olivier; Lesiak, Tadeusz; Leverington, Blake; Li, Yiming; Likhomanenko, Tatiana; Liles, Myfanwy; Lindner, Rolf; Linn, Christian; Lionetto, Federica; Liu, Bo; Liu, Xuesong; Loh, David; Longstaff, Iain; Lopes, Jose; Lucchesi, Donatella; Lucio Martinez, Miriam; Luo, Haofei; Lupato, Anna; Luppi, Eleonora; Lupton, Oliver; Lusiani, Alberto; Machefert, Frederic; Maciuc, Florin; Maev, Oleg; Maguire, Kevin; Malde, Sneha; Malinin, Alexander; Manca, Giulia; Mancinelli, Giampiero; Manning, Peter Michael; Mapelli, Alessandro; Maratas, Jan; Marchand, Jean François; Marconi, Umberto; Marin Benito, Carla; Marino, Pietro; Marks, Jörg; Martellotti, Giuseppe; Martin, Morgan; Martinelli, Maurizio; Martinez Santos, Diego; Martinez Vidal, Fernando; Martins Tostes, Danielle; Massafferri, André; Matev, Rosen; Mathad, Abhijit; Mathe, Zoltan; Matteuzzi, Clara; Mauri, Andrea; Maurin, Brice; Mazurov, Alexander; McCann, Michael; McCarthy, James; McNab, Andrew; McNulty, Ronan; Meadows, Brian; Meier, Frank; Meissner, Marco; Melnychuk, Dmytro; Merk, Marcel; Michielin, Emanuele; Milanes, Diego Alejandro; Minard, Marie-Noelle; Mitzel, Dominik Stefan; Molina Rodriguez, Josue; Monroy, Ignacio Alberto; Monteil, Stephane; Morandin, Mauro; Morawski, Piotr; Mordà, Alessandro; Morello, Michael Joseph; Moron, Jakub; Morris, Adam Benjamin; Mountain, Raymond; Muheim, Franz; Müller, Dominik; Müller, Janine; Müller, Katharina; Müller, Vanessa; Mussini, Manuel; Muster, Bastien; Naik, Paras; Nakada, Tatsuya; Nandakumar, Raja; Nandi, Anita; Nasteva, Irina; Needham, Matthew; Neri, Nicola; Neubert, Sebastian; Neufeld, Niko; Neuner, Max; Nguyen, Anh Duc; Nguyen, Thi-Dung; Nguyen-Mau, Chung; Niess, Valentin; Niet, Ramon; Nikitin, Nikolay; Nikodem, Thomas; Novoselov, Alexey; O'Hanlon, Daniel Patrick; Oblakowska-Mucha, Agnieszka; Obraztsov, Vladimir; Ogilvy, Stephen; Okhrimenko, Oleksandr; Oldeman, Rudolf; Onderwater, Gerco; Osorio Rodrigues, Bruno; Otalora Goicochea, Juan Martin; Otto, Adam; Owen, Patrick; Oyanguren, Maria Aranzazu; Palano, Antimo; Palombo, Fernando; Palutan, Matteo; Panman, Jacob; Papanestis, Antonios; Pappagallo, Marco; Pappalardo, Luciano; Pappenheimer, Cheryl; Parker, William; Parkes, Christopher; Passaleva, Giovanni; Patel, Girish; Patel, Mitesh; Patrignani, Claudia; Pearce, Alex; Pellegrino, Antonio; Penso, Gianni; Pepe Altarelli, Monica; Perazzini, Stefano; Perret, Pascal; Pescatore, Luca; Petridis, Konstantinos; Petrolini, Alessandro; Petruzzo, Marco; Picatoste Olloqui, Eduardo; Pietrzyk, Boleslaw; Pilař, Tomas; Pinci, Davide; Pistone, Alessandro; Piucci, Alessio; Playfer, Stephen; Plo Casasus, Maximo; Poikela, Tuomas; Polci, Francesco; Poluektov, Anton; Polyakov, Ivan; Polycarpo, Erica; Popov, Alexander; Popov, Dmitry; Popovici, Bogdan; Potterat, Cédric; Price, Eugenia; Price, Joseph David; Prisciandaro, Jessica; Pritchard, Adrian; Prouve, Claire; Pugatch, Valery; Puig Navarro, Albert; Punzi, Giovanni; Qian, Wenbin; Quagliani, Renato; Rachwal, Bartolomiej; Rademacker, Jonas; Rama, Matteo; Rangel, Murilo; Raniuk, Iurii; Rauschmayr, Nathalie; Raven, Gerhard; Redi, Federico; Reichert, Stefanie; Reid, Matthew; dos Reis, Alberto; Ricciardi, Stefania; Richards, Sophie; Rihl, Mariana; Rinnert, Kurt; Rives Molina, Vincente; Robbe, Patrick; Rodrigues, Ana Barbara; Rodrigues, Eduardo; Rodriguez Lopez, Jairo Alexis; Rodriguez Perez, Pablo; Roiser, Stefan; Romanovsky, Vladimir; Romero Vidal, Antonio; Ronayne, John William; Rotondo, Marcello; Rouvinet, Julien; Ruf, Thomas; Ruiz Valls, Pablo; Saborido Silva, Juan Jose; Sagidova, Naylya; Sail, Paul; Saitta, Biagio; Salustino Guimaraes, Valdir; Sanchez Mayordomo, Carlos; Sanmartin Sedes, Brais; Santacesaria, Roberta; Santamarina Rios, Cibran; Santimaria, Marco; Santovetti, Emanuele; Sarti, Alessio; Satriano, Celestina; Satta, Alessia; Saunders, Daniel Martin; Savrina, Darya; Schael, Stefan; Schiller, Manuel; Schindler, Heinrich; Schlupp, Maximilian; Schmelling, Michael; Schmelzer, Timon; Schmidt, Burkhard; Schneider, Olivier; Schopper, Andreas; Schubiger, Maxime; Schune, Marie Helene; Schwemmer, Rainer; Sciascia, Barbara; Sciubba, Adalberto; Semennikov, Alexander; Sergi, Antonino; Serra, Nicola; Serrano, Justine; Sestini, Lorenzo; Seyfert, Paul; Shapkin, Mikhail; Shapoval, Illya; Shcheglov, Yury; Shears, Tara; Shekhtman, Lev; Shevchenko, Vladimir; Shires, Alexander; Siddi, Benedetto Gianluca; Silva Coutinho, Rafael; Silva de Oliveira, Luiz Gustavo; Simi, Gabriele; Sirendi, Marek; Skidmore, Nicola; Skwarnicki, Tomasz; Smith, Edmund; Smith, Eluned; Smith, Iwan Thomas; Smith, Jackson; Smith, Mark; Snoek, Hella; Sokoloff, Michael; Soler, Paul; Soomro, Fatima; Souza, Daniel; Souza De Paula, Bruno; Spaan, Bernhard; Spradlin, Patrick; Sridharan, Srikanth; Stagni, Federico; Stahl, Marian; Stahl, Sascha; Stefkova, Slavomira; Steinkamp, Olaf; Stenyakin, Oleg; Stevenson, Scott; Stoica, Sabin; Stone, Sheldon; Storaci, Barbara; Stracka, Simone; Straticiuc, Mihai; Straumann, Ulrich; Sun, Liang; Sutcliffe, William; Swientek, Krzysztof; Swientek, Stefan; Syropoulos, Vasileios; Szczekowski, Marek; Szumlak, Tomasz; T'Jampens, Stephane; Tayduganov, Andrey; Tekampe, Tobias; Teklishyn, Maksym; Tellarini, Giulia; Teubert, Frederic; Thomas, Christopher; Thomas, Eric; van Tilburg, Jeroen; Tisserand, Vincent; Tobin, Mark; Todd, Jacob; Tolk, Siim; Tomassetti, Luca; Tonelli, Diego; Topp-Joergensen, Stig; Torr, Nicholas; Tournefier, Edwige; Tourneur, Stephane; Trabelsi, Karim; Tran, Minh Tâm; Tresch, Marco; Trisovic, Ana; Tsaregorodtsev, Andrei; Tsopelas, Panagiotis; Tuning, Niels; Ukleja, Artur; Ustyuzhanin, Andrey; Uwer, Ulrich; Vacca, Claudia; Vagnoni, Vincenzo; Valenti, Giovanni; Vallier, Alexis; Vazquez Gomez, Ricardo; Vazquez Regueiro, Pablo; Vázquez Sierra, Carlos; Vecchi, Stefania; van Veghel, Maarten; Velthuis, Jaap; Veltri, Michele; Veneziano, Giovanni; Vesterinen, Mika; Viaud, Benoit; Vieira, Daniel; Vieites Diaz, Maria; Vilasis-Cardona, Xavier; Volkov, Vladimir; Vollhardt, Achim; Volyanskyy, Dmytro; Voong, David; Vorobyev, Alexey; Vorobyev, Vitaly; Voß, Christian; de Vries, Jacco; Waldi, Roland; Wallace, Charlotte; Wallace, Ronan; Walsh, John; Wandernoth, Sebastian; Wang, Jianchun; Ward, David; Watson, Nigel; Websdale, David; Weiden, Andreas; Whitehead, Mark; Wilkinson, Guy; Wilkinson, Michael; Williams, Mark Richard James; Williams, Matthew; Williams, Mike; Williams, Timothy; Wilson, Fergus; Wimberley, Jack; Wishahi, Julian; Wislicki, Wojciech; Witek, Mariusz; Wormser, Guy; Wotton, Stephen; Wright, Simon; Wyllie, Kenneth; Xie, Yuehong; Xu, Zhirui; Yang, Zhenwei; Yu, Jiesheng; Yuan, Xuhao; Yushchenko, Oleg; Zangoli, Maria; Zavertyaev, Mikhail; Zhang, Liming; Zhang, Yanxi; Zhelezov, Alexey; Zhokhov, Anatoly; Zhong, Liang; Zhukov, Valery; Zucchelli, Stefano

    2016-01-01

    Two-particle angular correlations are studied in proton-lead collisions at a nucleon-nucleon centre-of-mass energy of $\\sqrt{s_{\\text{NN}}}=5$TeV, collected with the LHCb detector at the LHC. The analysis is based on data recorded in two beam configurations, in which either the direction of the proton or that of the lead ion is analysed. The correlations are measured as a function of relative pseudorapidity, $\\Delta\\eta$, and relative azimuthal angle, $\\Delta\\phi$, for events in different classes of event activity and for different bins of particle transverse momentum. In high-activity events a long-range correlation on the near side, $\\Delta\\phi \\approx 0$, is observed in the pseudorapidity range $2.0<\\eta<4.9$. This measurement of long-range correlations on the near side in proton-lead collisions extends previous observations into the forward region up to $\\eta=4.9$. The correlation increases with growing event activity and is found to be more pronounced in the direction of the lead beam. However, the...

  13. LHCb - First measurements of long-range near-side angular correlations in $\\sqrt {^SNN} = 5$ TeV proton-lead collisions in the forward region

    CERN Multimedia

    Yang, Zhenwei

    2015-01-01

    Two-particle angular correlations are studied in proton-lead collisions at a nucleon-nucleon centre-of-mass energy of $\\sqrt {^SNN} = 5$ TeV, collected with the LHCb detector at the LHC. The analysis is based on data recorded in two opposing beam configurations, in which either the direction of the proton or that of the lead remnant is analysed. The correlations are measured as a function of relative pseudorapidity, $\\Delta \\eta$, and relative azimuthal angle, $\\Delta \\phi$, for events in different classes of event activity and for different bins of particle transverse momentum. In high-activity events a long-range correlation on the near side is observed in the pseudorapidity range $2.0 < \\eta < 4.9$. This is the first measurement of a long-range correlation on the near side in proton-lead collisions in the forward region and extends previous observations in the central region. The correlation increases with growing event activity and is found to be more pronounced in the direction of the lead beam. Wh...

  14. Wireless network of stand-alone end effect probes for soil in situ permittivity measurements over the 100MHZ-6GHz frequency range

    Science.gov (United States)

    Demontoux, François; Bircher, Simone; Ruffié, Gilles; Bonnaudiin, Fabrice; Wigneron, Jean-Pierre; Kerr, Yann

    2017-04-01

    Microwave remote sensing and non-destructive analysis are a powerful way to provide properties estimation of materials. Numerous applications using microwave frequency behavior of materials (remote sensing above land surfaces, non-destructive analysis…) are strongly dependent on the material's permittivity (i.e. dielectric properties). This permittivity depends on numerous parameters such as moisture, texture, temperature, frequency or bulk density. Permittivity measurements are generally carried out in the laboratory. Additionally, dielectric mixing models allow, over a restricted range of conditions, the assessment of a material's permittivity. in-situ measurements are more difficult to obtain. Some in situ measurement probes based on permittivity properties of soil exist (e.g. Time Domain Reflectometers and Transmissometers, capacitance and impedance sensors). They are dedicated to the acquisition of soil moisture data based on permittivity (mainly the real part) estimations over a range of frequencies from around 50 MHz to 1 or 2 GHz. Other Dielectric Assessment Kits exist but they are expensive and they are rather dedicated to laboratory measurements. Furthermore, the user can't address specific issues related to particular materials (e.g. organic soils) or specific measurement conditions (in situ long time records). At the IMS Laboratory we develop probes for in situ soil permittivity measurements (real and imaginary parts) in the 0.5 - 6 GHz frequency range. They are based on the end effect phenomenon of a coaxial waveguide and so are called end effect probes in this paper. The probes can be connected to a portable Vector Network Analyzer (VNA, ANRITSU MS2026A) for the S11 coefficient measurements needed to compute permittivity. It is connected to a PC to record data using an USB connection. This measurement set-up is already used for in situ measurement of soil properties in the framework of the European Space Agency's (ESA) SMOS space mission. However

  15. Do mainframe à nuvem: inovações, estrutura industrial e modelos de negócios nas tecnologias da informação e da comunicação

    OpenAIRE

    Paulo Bastos Tigre; Vitor Branco Noronha

    2013-01-01

    Inovações radicais nas tecnologias da informação e da comunicação (TIC) abrem oportunidades para o desenvolvimento de novos modelos de negócios que, quando bem-sucedidos, acabam por alterar a própria estrutura da indústria global. A partir da revisão de mudanças estruturais ocorridas nas TIC nas últimas cinco décadas, neste artigo analisam-se a relação entre novas tecnologias, o surgimento de empresas consideradas paradigmas e seus respectivos modelos de negócios visando contribuir para o pro...

  16. Modelo conceitual de decisões no estágio de criação de um negócio: base para construção de um simulador para jogos de empresas

    OpenAIRE

    André Rosenfeld Rosas; Antonio Carlos Aidar Sauaia

    2009-01-01

    O estudo teve como objetivo desenvolver um modelo conceitual para jogo de empresas que reúne as principais decisões de um empreendedor no estágio de criação de um negócio. As decisões, identificadas na literatura de empreendedorismo que foca o processo de criação de negócios, foram modeladas pelo método do diagrama de influências e confirmadas com especialistas norte-americanos e brasileiros no tema. O modelo conceitual resultante, aqui proposto para a criação de um simulador, foi comparado a...

  17. Secondary neutron spectrum from 250-MeV passively scattered proton therapy: Measurement with an extended-range Bonner sphere system

    Energy Technology Data Exchange (ETDEWEB)

    Howell, Rebecca M., E-mail: rhowell@mdanderson.org [Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030 (United States); Burgett, E. A. [Department of Nuclear Engineering, Idaho State University, Pocatello, Idaho 83201 (United States)

    2014-09-15

    Purpose: Secondary neutrons are an unavoidable consequence of proton therapy. While the neutron dose is low compared to the primary proton dose, its presence and contribution to the patient dose is nonetheless important. The most detailed information on neutrons includes an evaluation of the neutron spectrum. However, the vast majority of the literature that has reported secondary neutron spectra in proton therapy is based on computational methods rather than measurements. This is largely due to the inherent limitations in the majority of neutron detectors, which are either not suitable for spectral measurements or have limited response at energies greater than 20 MeV. Therefore, the primary objective of the present study was to measure a secondary neutron spectrum from a proton therapy beam using a spectrometer that is sensitive to neutron energies over the entire neutron energy spectrum. Methods: The authors measured the secondary neutron spectrum from a 250-MeV passively scattered proton beam in air at a distance of 100 cm laterally from isocenter using an extended-range Bonner sphere (ERBS) measurement system. Ambient dose equivalent H*(10) was calculated using measured fluence and fluence-to-ambient dose equivalent conversion coefficients. Results: The neutron fluence spectrum had a high-energy direct neutron peak, an evaporation peak, a thermal peak, and an intermediate energy continuum between the thermal and evaporation peaks. The H*(10) was dominated by the neutrons in the evaporation peak because of both their high abundance and the large quality conversion coefficients in that energy interval. The H*(10) 100 cm laterally from isocenter was 1.6 mSv per proton Gy (to isocenter). Approximately 35% of the dose equivalent was from neutrons with energies ≥20 MeV. Conclusions: The authors measured a neutron spectrum for external neutrons generated by a 250-MeV proton beam using an ERBS measurement system that was sensitive to neutrons over the entire

  18. Secondary neutron spectrum from 250-MeV passively scattered proton therapy: measurement with an extended-range Bonner sphere system.

    Science.gov (United States)

    Howell, Rebecca M; Burgett, E A

    2014-09-01

    Secondary neutrons are an unavoidable consequence of proton therapy. While the neutron dose is low compared to the primary proton dose, its presence and contribution to the patient dose is nonetheless important. The most detailed information on neutrons includes an evaluation of the neutron spectrum. However, the vast majority of the literature that has reported secondary neutron spectra in proton therapy is based on computational methods rather than measurements. This is largely due to the inherent limitations in the majority of neutron detectors, which are either not suitable for spectral measurements or have limited response at energies greater than 20 MeV. Therefore, the primary objective of the present study was to measure a secondary neutron spectrum from a proton therapy beam using a spectrometer that is sensitive to neutron energies over the entire neutron energy spectrum. The authors measured the secondary neutron spectrum from a 250-MeV passively scattered proton beam in air at a distance of 100 cm laterally from isocenter using an extended-range Bonner sphere (ERBS) measurement system. Ambient dose equivalent H*(10) was calculated using measured fluence and fluence-to-ambient dose equivalent conversion coefficients. The neutron fluence spectrum had a high-energy direct neutron peak, an evaporation peak, a thermal peak, and an intermediate energy continuum between the thermal and evaporation peaks. The H*(10) was dominated by the neutrons in the evaporation peak because of both their high abundance and the large quality conversion coefficients in that energy interval. The H*(10) 100 cm laterally from isocenter was 1.6 mSv per proton Gy (to isocenter). Approximately 35% of the dose equivalent was from neutrons with energies ≥20 MeV. The authors measured a neutron spectrum for external neutrons generated by a 250-MeV proton beam using an ERBS measurement system that was sensitive to neutrons over the entire energy range being measured, i.e., thermal to

  19. Temperature dependence of the thermal diffusivity of GaAs in the 100-305 K range measured by the pulsed photothermal displacement technique

    Science.gov (United States)

    Soltanolkotabi, M.; Bennis, G. L.; Gupta, R.

    1999-01-01

    We have measured the variation of the value of the thermal diffusivity of semi-insulating GaAs in the 100-305 K range. The method used is the pulsed photothermal displacement technique. This is a noncontact technique, and the value of the thermal diffusivity is derived from the temporal evolution of the signal rather than its amplitude. This makes the technique less susceptible to uncertainties. We find that the temperature dependence of the thermal conductivity of semi-insulating GaAs follows a power law as T-1.62, in disagreement with results obtained previously. Possible reasons for the deviation within this very important intermediate temperature range are discussed.

  20. Endocrine correlates of musth in free-ranging Asian elephants (Elephas maximus determined by non-invasive faecal steroid hormone metabolite measurements.

    Directory of Open Access Journals (Sweden)

    Ratna Ghosal

    Full Text Available The occurrence of musth, a period of elevated levels of androgens and heightened sexual activity, has been well documented for the male Asian elephant (Elephas maximus. However, the relationship between androgen-dependent musth and adrenocortical function in this species is unclear. The current study is the first assessment of testicular and adrenocortical function in free-ranging male Asian elephants by measuring levels of testosterone (androgen and cortisol (glucocorticoid--a physiological indicator of stress metabolites in faeces. During musth, males expectedly showed significant elevation in faecal testosterone metabolite levels. Interestingly, glucocorticoid metabolite concentrations remained unchanged between musth and non-musth periods. This observation is contrary to that observed with wild and captive African elephant bulls and captive Asian bull elephants. Our results show that musth may not necessarily represent a stressful condition in free-ranging male Asian elephants.

  1. Optical properties measurement of laser coagulated tissues with double integrating sphere and inverse Monte Carlo technique in the wavelength range from 350 to 2100 nm

    Science.gov (United States)

    Honda, Norihiro; Nanjo, Takuya; Ishii, Katsunori; Awazu, Kunio

    2012-03-01

    In laser medicine, the accurate knowledge about the optical properties (absorption coefficient; μa, scattering coefficient; μs, anisotropy factor; g) of laser irradiated tissues is important for the prediction of light propagation in tissues, since the efficacy of laser treatment depends on the photon propagation within the irradiated tissues. Thus, it is likely that the optical properties of tissues at near-ultraviolet, visible and near-infrared wavelengths will be more important due to more biomedical applications of lasers will be developed. For improvement of the laser induced thermotherapy, the optical property change during laser treatment should be considered in the wide wavelength range. For estimation of the optical properties of the biological tissues, the optical properties measurement system with a double integrating sphere setup and an inverse Monte Carlo technique was developed. The optical properties of chicken muscle tissue were measured in the native state and after laser coagulation using the optical properties measurement system in the wavelength range from 350 to 2100 nm. A CO2 laser was used for laser coagulation. After laser coagulation, the reduced scattering coefficient of the tissue increased. And, the optical penetration depth decreased. For improvement of the treatment depth during laser coagulation, a quantitative procedure using the treated tissue optical properties for determination of the irradiation power density following light penetration decrease might be important in clinic.

  2. Medium-Range Order in Amorphous Silicon Measured by Fluctuation Electron Microscopy: Final Report, 23 June 1999--23 August 2002

    Energy Technology Data Exchange (ETDEWEB)

    Voyles, P. M.; Abelson, J. R.

    2003-10-01

    Despite occasional experimental hints, medium-range structural order in covalently bonded amorphous semiconductors had largely escaped detection until the advent of fluctuation electron microscopy (FEM) in 1996. Using FEM, we find that every sample of amorphous silicon and germanium we have investigated, regardless of deposition method or hydrogen content, is rich in medium-range order. The paracrystalline structural model, which consists of small, topologically ordered grains in an amorphous matrix, is consistent with the FEM data; but due to strain effects, materials with a paracrystalline structure appear to be amorphous in diffraction measurements. We present measurements on hydrogenated amorphous silicon deposited by different methods, some of which are reported to have greater stability against the Staebler-Wronski effect. FEM reveals that the matrix material of these samples is relatively similar, but the order changes in different ways upon both light soaking and thermal annealing. Some materials are inhomogeneous, with either nanocrystalline inclusions or large area-to-area variation in the medium-range order. We cite recent calculations that electronic states in the conduction band tail are preferentially located around the boundaries of the nm-scale paracrystalline regions that we have identified. This is new evidence in support of spatially inhomogeneous conduction mechanisms in a-Si. The key discovery in our work is that all samples of amorphous silicon must be described as having nm-scale topological crystalline order. This strongly modifies the long-standing model of a covalent random network. Our new understanding of medium-range order must be considered in all future models of electronic properties and the Staebler-Wronski effect.

  3. CLINICAL MEASURES OF HIP RANGE OF MOTION DO NOT CORRELATE WITH THE DEGREE OF CAM MORPHOLOGY IN SEMI-ELITE AUSTRALIAN FOOTBALLERS: A CROSS-SECTIONAL STUDY.

    Science.gov (United States)

    Murphy, Myles; Kemp, Joanne; Smith, Anne; Charlesworth, Jonathon; Briffa, Kathy

    2017-12-01

    Clinical testing to determine the presence of a cam morphology is becoming more common however the correlation between hip range of motion and the degree of cam morphology remains controversial in the literature. The prevalence of a cam morphology in athletes has been reported as higher than in the general population but the prevalence of cam morphology has not been reported in Australian Football (AF). The purpose of this study was to determine the correlation between hip range of motion and hip alpha angle and report the proportion of players with a cam morphology in a sample of AF players. Cross-sectional Study. Twenty-one semi-elite AF players (42 hips) from the Peel Thunder Football Club were included in this study. A hip Flexion Internal Rotation (IR) test and a modified maximal squat test using the difference in depth of squat in hip internal and external rotation were used. These measures were then compared to alpha angles on 90 degree Dunn view x-rays. Four of the 42 hips (9.5%) had a cam morphology (alpha angle > 60 degrees). There was no significant correlation between alpha angle and ROM in a Flexion IR test or the difference in modified maximal squat test depth within this sample of players. The proportion of cam morphology seems to be lower in this sample than the previously reported prevalence in other sports. The lack of correlations between hip range and hip alpha angle in players means that screening hips using clinical measures to detect cam morphology associated with poor hip range of motion may be inaccurate. Level 3a.

  4. Refractive index measurements of films with biaxial symmetry. 2. Determination of film thickness and refractive indices using polarized transmission spectra in the transparent wavelength range.

    Science.gov (United States)

    Diao, Jie; Hess, Dennis W

    2005-07-07

    A technique is formulated to determine both thickness and refractive indices of free-standing films with biaxial symmetry from polarized transmission spectra. The films must be transparent and show little dispersion in refractive indices in the wavelength range where the transmission spectra are collected. Methods are proposed to correct the errors caused by imperfect polarization of incident radiation and thickness variation across the sampling area. Anisotropic refractive indices and thickness of poly(biphenyl dianhydride-p-phenylenediamine) films which exhibit uniaxial optical anisotropy are determined from polarized transmission spectra. The refractive index and thickness values compare well to those obtained from waveguide prism coupler and profilometer measurements.

  5. Reliability of the intra and inter-test measures with universal goniometer and podalic arthrometer of the active range of ankle inversion and eversion

    OpenAIRE

    Araújo, Ana Gabriela de Figueiredo; Barbosa, Germanna de Medeiros; Freire, Roberta de Andrade; Andrade, Palloma Rodrigues de; Ferreira, José Jamacy de Almeida; Santos, Heleodório Honorato dos

    2014-01-01

    The objective this study was to evaluate intra and inter-rater and inter-instruments reliability of ankle inversion and eversion active range of motion. The study included 100 healthy individuals (71 women and 29 men; ages: 21.32±2.83 years old; body mass: 60.40±4.95 kg; height: 1.66±0.04 m; and body mass index: 21.89±2.83 kg/m2), who were submitted to measurement of ankle inversion and eversion using the universal goniometer and podalic arthrometer. We used the intra-class correlation coeffi...

  6. The application of multi-baseline digital close-range photogrammetry in three-dimensional imaging and measurement of dental casts.

    Directory of Open Access Journals (Sweden)

    Xiaoming Fu

    Full Text Available To explore a new technique for reconstructing and measuring three-dimensional (3D models of orthodontic plaster casts using multi-baseline digital close-range photogrammetry (MBDCRP with a single-lens reflex camera.Thirty sets of orthodontic plaster casts that do not exhibit severe horizontal overlap (>2 mm between any two teeth were recorded by a single-lens reflex camera with 72 pictures taken in different directions. The 3D models of these casts were reconstructed and measured using the open source software MeshLab. These parameters, including mesio-distal crown diameter, arch width, and arch perimeter, were recorded six times on both the 3D digital models and on plaster casts by two examiners. Statistical analysis was carried out using the Bland-Altman method to measure agreement between the novel method and the traditional calliper method by calculating the differences between mean values.The average differences between the measurements of the photogrammetric 3D models and the plaster casts were 0.011-0.402mm. The mean differences between measurements obtained by the photogrammetric 3D models and the dental casts were not significant except for the lower arch perimeter (P>0.05, and all the differences were regarded as clinically acceptable (<0.5 mm.Measurements obtained by MBDCRP are compared well with those obtained from plaster casts, indicating that MBDCRP is an alternate way to store and measure dental plaster casts without severe horizontal overlap between any two teeth.

  7. Compact Antenna Range

    Data.gov (United States)

    Federal Laboratory Consortium — Facility consists of a folded compact antenna range including a computer controlled three axis position table, parabolic reflector and RF sources for the measurement...

  8. Measurements of double differential charged particle emission cross sections and development of a wide range charged particles spectrometer for ten`s MeV neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Nauchi, Yasushi; Baba, Mamoru; Kiyosumi, Takehide [Tohoku Univ., Sendai (Japan). Faculty of Engineering] [and others

    1997-03-01

    We measured (n,xp), (n,xd) cross sections of C and Al for En=64.3 MeV neutrons at the {sup 7}Li(p,n) neutron sources facility at TIARA (Takasaki Establishment, JAERI) by using a conventional SSD-NaI telescope placed in the air. They show characteristic energy and angular dependence in high energy regions. In order to extend the measurements to low energy protons and {alpha} particles, a new spectrometer consisting of low pressure gas counters and BaF{sub 2} scintillators is now under development. A low threshold for low energy {alpha} particles will be achieved by using the gas counters. The particle identification over a wide energy range will be achieved by combining the {Delta}E-E method for low energy particles with the pulse shape discrimination (PSD) method of BaF{sub 2} for high energy particles. (author)

  9. Measurement of mass attenuation coefficients of some boron compounds and the trommel sieve waste in the energy range 15.746-40.930 keV

    Energy Technology Data Exchange (ETDEWEB)

    Icelli, Orhan E-mail: orhan_icelli@hotmail.com; Erzeneoglu, Salih; Boncukcuoglu, Recep

    2003-05-01

    Mass attenuation coefficients of some boron compounds (H{sub 3}BO{sub 3}, Na{sub 2}B{sub 4}O{sub 7} and B{sub 3}Al{sub 2}O{sub 3}) and the trommel sieve waste (TSW) have been measured by using an extremely narrow collimated-beam transmission method in the energy range 15.746-40.930 keV. The characteristic K{alpha} and K{beta} X-rays of Zr, Mo, Ag, In, Sb, Ba and Pr passed through H{sub 3}BO{sub 3}, Na{sub 2}B{sub 4}O{sub 7}, B{sub 3}Al{sub 2}O{sub 3} and TSW were detected with a high-resolution Si(Li) detector. The measured values are compared with the theoretical ones obtained using the WINXCOM.

  10. The Activation of Non-evaporable Getters Monitored by AES, XPS, SSIMS and Secondary Electron Yield Measurements

    CERN Document Server

    Scheuerlein, C

    2002-01-01

    In this thesis the potential of the three classical surface analysis techniques Auger electron spectroscopy (AES), X-ray photoelectron spectroscopy (XPS) and static secondary ion mass spectrometry (SSIMS) for the characterisation of non-evaporable getter (NEG) materials is assessed and artefacts are described. The various NEG samples have been analysed in the context of the development of NEG thin film coatings for use in accelerator ultra high vacuum (UHV) systems. The secondary electron yield (SEY), which is a functional surface property of great importance for the application of NEG to accelerators, has been measured. The maximum SEY of an air exposed TiZr and TiZrV coating can be reduced from above 2.0 to below 1.1 during a 2 h heat treatment at 250 and 200 °C, respectively. Saturating an activated TiZrV surface in UHV increases the maximum SEY by about 0.1. Thus, in UHV the SEY of an activated NEG coating does not exceed the threshold value of 1.35, above which multipacting is predicted to occur in th...

  11. Investigating the influence of long-range transport on surface O{sub 3} in Nevada, USA, using observations from multiple measurement platforms

    Energy Technology Data Exchange (ETDEWEB)

    Fine, Rebekka, E-mail: rebekkafine@gmail.com [Department of Natural Resources and Environmental Science, University of Nevada-Reno, Reno, NV (United States); Miller, Matthieu B. [Department of Natural Resources and Environmental Science, University of Nevada-Reno, Reno, NV (United States); Yates, Emma L.; Iraci, Laura T. [Atmospheric Science Branch, NASA Ames Research Center, Moffett Field, CA 94035 (United States); Gustin, Mae Sexauer, E-mail: mgustin@cabnr.unr.edu [Department of Natural Resources and Environmental Science, University of Nevada-Reno, Reno, NV (United States)

    2015-10-15

    The current United States (US) National Ambient Air Quality Standard (NAAQS) for O{sub 3} (75 ppb) is expected to be revised to between 60 and 70 ppb. As the NAAQS becomes more stringent, characterizing the extent of O{sub 3} and precursors transported into the US is increasingly important. Given the high elevation, complex terrain, and location in the Intermountain West, the State of Nevada is ideally situated to intercept air transported into the US. Until recently, measurements of O{sub 3} and associated pollutants were limited to areas in and around the cities of Las Vegas and Reno. In 2011, the Nevada Rural Ozone Initiative began and through this project 13 surface monitoring sites were established. Also in 2011, the NASA Ames Alpha Jet Atmospheric eXperiment (AJAX) began making routine aircraft measurements of O{sub 3} and other greenhouse gases in Nevada. The availability of aircraft and surface measurements in a relatively rural, remote setting in the Intermountain West presented a unique opportunity to investigate sources contributing to the O{sub 3} observed in Nevada. Our analyses indicate that stratosphere to troposphere transport, long-range transport of Asian pollution, and regional emissions from urban areas and wildfires influence surface observations. The complexity of sources identified here along with the fact that O{sub 3} frequently approaches the threshold being considered for a revised NAAQS indicate that interstate and international cooperation will be necessary to achieve compliance with a more stringent regulatory standard. Further, on a seasonal basis we found no significant difference between daily 1-h maximum O{sub 3} at surface sites, which ranged in elevation from 888 to 2307 m, and aircraft measurements of O{sub 3} < 2500 m which suggests that similar processes influence daytime O{sub 3} across rural Nevada and indicates that column measurements from Railroad Valley, NV are useful in understanding these processes. - Highlights:

  12. Measurement of long-range near-side two-particle angular correlations in pp collisions at $\\sqrt{s} =$ 13 TeV

    CERN Document Server

    Khachatryan, Vardan; Tumasyan, Armen; Adam, Wolfgang; Aşılar, Ece; Bergauer, Thomas; Brandstetter, Johannes; Brondolin, Erica; Dragicevic, Marko; Erö, Janos; Flechl, Martin; Friedl, Markus; Fruehwirth, Rudolf; Ghete, Vasile Mihai; Hartl, Christian; Hörmann, Natascha; Hrubec, Josef; Jeitler, Manfred; Knünz, Valentin; König, Axel; Krammer, Manfred; Krätschmer, Ilse; Liko, Dietrich; Matsushita, Takashi; Mikulec, Ivan; Rabady, Dinyar; Rahbaran, Babak; Rohringer, Herbert; Schieck, Jochen; Schöfbeck, Robert; Strauss, Josef; Treberer-Treberspurg, Wolfgang; Waltenberger, Wolfgang; Wulz, Claudia-Elisabeth; Mossolov, Vladimir; Shumeiko, Nikolai; Suarez Gonzalez, Juan; Alderweireldt, Sara; Cornelis, Tom; De Wolf, Eddi A; Janssen, Xavier; Knutsson, Albert; Lauwers, Jasper; Luyckx, Sten; Van De Klundert, Merijn; Van Haevermaet, Hans; Van Mechelen, Pierre; Van Remortel, Nick; Van Spilbeeck, Alex; Abu Zeid, Shimaa; Blekman, Freya; D'Hondt, Jorgen; Daci, Nadir; De Bruyn, Isabelle; Deroover, Kevin; Heracleous, Natalie; Keaveney, James; Lowette, Steven; Moreels, Lieselotte; Olbrechts, Annik; Python, Quentin; Strom, Derek; Tavernier, Stefaan; Van Doninck, Walter; Van Mulders, Petra; Van Onsem, Gerrit Patrick; Van Parijs, Isis; Barria, Patrizia; Brun, Hugues; Caillol, Cécile; Clerbaux, Barbara; De Lentdecker, Gilles; Fasanella, Giuseppe; Favart, Laurent; Grebenyuk, Anastasia; Karapostoli, Georgia; Lenzi, Thomas; Léonard, Alexandre; Maerschalk, Thierry; Marinov, Andrey; Perniè, Luca; Randle-conde, Aidan; Seva, Tomislav; Vander Velde, Catherine; Vanlaer, Pascal; Yonamine, Ryo; Zenoni, Florian; Zhang, Fengwangdong; Beernaert, Kelly; Benucci, Leonardo; Cimmino, Anna; Crucy, Shannon; Dobur, Didar; Fagot, Alexis; Garcia, Guillaume; Gul, Muhammad; Mccartin, Joseph; Ocampo Rios, Alberto Andres; Poyraz, Deniz; Ryckbosch, Dirk; Salva Diblen, Sinem; Sigamani, Michael; Tytgat, Michael; Van Driessche, Ward; Yazgan, Efe; Zaganidis, Nicolas; Basegmez, Suzan; Beluffi, Camille; Bondu, Olivier; Brochet, Sébastien; Bruno, Giacomo; Caudron, Adrien; Ceard, Ludivine; Da Silveira, Gustavo Gil; Delaere, Christophe; Favart, Denis; Forthomme, Laurent; Giammanco, Andrea; Hollar, Jonathan; Jafari, Abideh; Jez, Pavel; Komm, Matthias; Lemaitre, Vincent; Mertens, Alexandre; Musich, Marco; Nuttens, Claude; Perrini, Lucia; Pin, Arnaud; Piotrzkowski, Krzysztof; Popov, Andrey; Quertenmont, Loic; Selvaggi, Michele; Vidal Marono, Miguel; Beliy, Nikita; Hammad, Gregory Habib; Aldá Júnior, Walter Luiz; Alves, Fábio Lúcio; Alves, Gilvan; Brito, Lucas; Correa Martins Junior, Marcos; Hamer, Matthias; Hensel, Carsten; Moraes, Arthur; Pol, Maria Elena; Rebello Teles, Patricia; Belchior Batista Das Chagas, Ewerton; Carvalho, Wagner; Chinellato, Jose; Custódio, Analu; Melo Da Costa, Eliza; De Jesus Damiao, Dilson; De Oliveira Martins, Carley; Fonseca De Souza, Sandro; Huertas Guativa, Lina Milena; Malbouisson, Helena; Matos Figueiredo, Diego; Mora Herrera, Clemencia; Mundim, Luiz; Nogima, Helio; Prado Da Silva, Wanda Lucia; Santoro, Alberto; Sznajder, Andre; Tonelli Manganote, Edmilson José; Vilela Pereira, Antonio; Ahuja, Sudha; Bernardes, Cesar Augusto; De Souza Santos, Angelo; Dogra, Sunil; Tomei, Thiago; De Moraes Gregores, Eduardo; Mercadante, Pedro G; Moon, Chang-Seong; Novaes, Sergio F; Padula, Sandra; Romero Abad, David; Ruiz Vargas, José Cupertino; Aleksandrov, Aleksandar; Hadjiiska, Roumyana; Iaydjiev, Plamen; Rodozov, Mircho; Stoykova, Stefka; Sultanov, Georgi; Vutova, Mariana; Dimitrov, Anton; Glushkov, Ivan; Litov, Leander; Pavlov, Borislav; Petkov, Peicho; Ahmad, Muhammad; Bian, Jian-Guo; Chen, Guo-Ming; Chen, He-Sheng; Chen, Mingshui; Cheng, Tongguang; Du, Ran; Jiang, Chun-Hua; Plestina, Roko; Romeo, Francesco; Shaheen, Sarmad Masood; Spiezia, Aniello; Tao, Junquan; Wang, Chunjie; Wang, Zheng; Zhang, Huaqiao; Asawatangtrakuldee, Chayanit; Ban, Yong; Li, Qiang; Liu, Shuai; Mao, Yajun; Qian, Si-Jin; Wang, Dayong; Xu, Zijun; Avila, Carlos; Cabrera, Andrés; Chaparro Sierra, Luisa Fernanda; Florez, Carlos; Gomez, Juan Pablo; Gomez Moreno, Bernardo; Sanabria, Juan Carlos; Godinovic, Nikola; Lelas, Damir; Puljak, Ivica; Ribeiro Cipriano, Pedro M; Antunovic, Zeljko; Kovac, Marko; Brigljevic, Vuko; Kadija, Kreso; Luetic, Jelena; Micanovic, Sasa; Sudic, Lucija; Attikis, Alexandros; Mavromanolakis, Georgios; Mousa, Jehad; Nicolaou, Charalambos; Ptochos, Fotios; Razis, Panos A; Rykaczewski, Hans; Bodlak, Martin; Finger, Miroslav; Finger Jr, Michael; El-khateeb, Esraa; Elkafrawy, Tamer; Mohamed, Amr; Salama, Elsayed; Calpas, Betty; Kadastik, Mario; Murumaa, Marion; Raidal, Martti; Tiko, Andres; Veelken, Christian; Eerola, Paula; Pekkanen, Juska; Voutilainen, Mikko; Härkönen, Jaakko; Karimäki, Veikko; Kinnunen, Ritva; Lampén, Tapio; Lassila-Perini, Kati; Lehti, Sami; Lindén, Tomas; Luukka, Panja-Riina; Peltola, Timo; Tuominen, Eija; Tuominiemi, Jorma; Tuovinen, Esa; Wendland, Lauri; Talvitie, Joonas; Tuuva, Tuure; Besancon, Marc; Couderc, Fabrice; Dejardin, Marc; Denegri, Daniel; Fabbro, Bernard; Faure, Jean-Louis; Favaro, Carlotta; Ferri, Federico; Ganjour, Serguei; Givernaud, Alain; Gras, Philippe; Hamel de Monchenault, Gautier; Jarry, Patrick; Locci, Elizabeth; Machet, Martina; Malcles, Julie; Rander, John; Rosowsky, André; Titov, Maksym; Zghiche, Amina; Antropov, Iurii; Baffioni, Stephanie; Beaudette, Florian; Busson, Philippe; Cadamuro, Luca; Chapon, Emilien; Charlot, Claude; Davignon, Olivier; Filipovic, Nicolas; Granier de Cassagnac, Raphael; Jo, Mihee; Lisniak, Stanislav; Mastrolorenzo, Luca; Miné, Philippe; Naranjo, Ivo Nicolas; Nguyen, Matthew; Ochando, Christophe; Ortona, Giacomo; Paganini, Pascal; Pigard, Philipp; Regnard, Simon; Salerno, Roberto; Sauvan, Jean-Baptiste; Sirois, Yves; Strebler, Thomas; Yilmaz, Yetkin; Zabi, Alexandre; Agram, Jean-Laurent; Andrea, Jeremy; Aubin, Alexandre; Bloch, Daniel; Brom, Jean-Marie; Buttignol, Michael; Chabert, Eric Christian; Chanon, Nicolas; Collard, Caroline; Conte, Eric; Coubez, Xavier; Fontaine, Jean-Charles; Gelé, Denis; Goerlach, Ulrich; Goetzmann, Christophe; Le Bihan, Anne-Catherine; Merlin, Jeremie Alexandre; Skovpen, Kirill; Van Hove, Pierre; Gadrat, Sébastien; Beauceron, Stephanie; Bernet, Colin; Boudoul, Gaelle; Bouvier, Elvire; Carrillo Montoya, Camilo Andres; Chierici, Roberto; Contardo, Didier; Courbon, Benoit; Depasse, Pierre; El Mamouni, Houmani; Fan, Jiawei; Fay, Jean; Gascon, Susan; Gouzevitch, Maxime; Ille, Bernard; Lagarde, Francois; Laktineh, Imad Baptiste; Lethuillier, Morgan; Mirabito, Laurent; Pequegnot, Anne-Laure; Perries, Stephane; Ruiz Alvarez, José David; Sabes, David; Sgandurra, Louis; Sordini, Viola; Vander Donckt, Muriel; Verdier, Patrice; Viret, Sébastien; Toriashvili, Tengizi; Tsamalaidze, Zviad; Autermann, Christian; Beranek, Sarah; Feld, Lutz; Heister, Arno; Kiesel, Maximilian Knut; Klein, Katja; Lipinski, Martin; Ostapchuk, Andrey; Preuten, Marius; Raupach, Frank; Schael, Stefan; Schulte, Jan-Frederik; Verlage, Tobias; Weber, Hendrik; Zhukov, Valery; Ata, Metin; Brodski, Michael; Dietz-Laursonn, Erik; Duchardt, Deborah; Endres, Matthias; Erdmann, Martin; Erdweg, Sören; Esch, Thomas; Fischer, Robert; Güth, Andreas; Hebbeker, Thomas; Heidemann, Carsten; Hoepfner, Kerstin; Knutzen, Simon; Kreuzer, Peter; Merschmeyer, Markus; Meyer, Arnd; Millet, Philipp; Mukherjee, Swagata; Olschewski, Mark; Padeken, Klaas; Papacz, Paul; Pook, Tobias; Radziej, Markus; Reithler, Hans; Rieger, Marcel; Scheuch, Florian; Sonnenschein, Lars; Teyssier, Daniel; Thüer, Sebastian; Cherepanov, Vladimir; Erdogan, Yusuf; Flügge, Günter; Geenen, Heiko; Geisler, Matthias; Hoehle, Felix; Kargoll, Bastian; Kress, Thomas; Kuessel, Yvonne; Künsken, Andreas; Lingemann, Joschka; Nehrkorn, Alexander; Nowack, Andreas; Nugent, Ian Michael; Pistone, Claudia; Pooth, Oliver; Stahl, Achim; Aldaya Martin, Maria; Asin, Ivan; Bartosik, Nazar; Behnke, Olaf; Behrens, Ulf; Bell, Alan James; Borras, Kerstin; Burgmeier, Armin; Campbell, Alan; Costanza, Francesco; Diez Pardos, Carmen; Dolinska, Ganna; Dooling, Samantha; Dorland, Tyler; Eckerlin, Guenter; Eckstein, Doris; Eichhorn, Thomas; Flucke, Gero; Gallo, Elisabetta; Garay Garcia, Jasone; Geiser, Achim; Gizhko, Andrii; Gunnellini, Paolo; Hauk, Johannes; Hempel, Maria; Jung, Hannes; Kalogeropoulos, Alexis; Karacheban, Olena; Kasemann, Matthias; Katsas, Panagiotis; Kieseler, Jan; Kleinwort, Claus; Korol, Ievgen; Lange, Wolfgang; Leonard, Jessica; Lipka, Katerina; Lobanov, Artur; Lohmann, Wolfgang; Mankel, Rainer; Marfin, Ihar; Melzer-Pellmann, Isabell-Alissandra; Meyer, Andreas Bernhard; Mittag, Gregor; Mnich, Joachim; Mussgiller, Andreas; Naumann-Emme, Sebastian; Nayak, Aruna; Ntomari, Eleni; Perrey, Hanno; Pitzl, Daniel; Placakyte, Ringaile; Raspereza, Alexei; Roland, Benoit; Sahin, Mehmet Özgür; Saxena, Pooja; Schoerner-Sadenius, Thomas; Seitz, Claudia; Spannagel, Simon; Trippkewitz, Karim Damun; Walsh, Roberval; Wissing, Christoph; Blobel, Volker; Centis Vignali, Matteo; Draeger, Arne-Rasmus; Erfle, Joachim; Garutti, Erika; Goebel, Kristin; Gonzalez, Daniel; Görner, Martin; Haller, Johannes; Hoffmann, Malte; Höing, Rebekka Sophie; Junkes, Alexandra; Klanner, Robert; Kogler, Roman; Kovalchuk, Nataliia; Lapsien, Tobias; Lenz, Teresa; Marchesini, Ivan; Marconi, Daniele; Meyer, Mareike; Nowatschin, Dominik; Ott, Jochen; Pantaleo, Felice; Peiffer, Thomas; Perieanu, Adrian; Pietsch, Niklas; Poehlsen, Jennifer; Rathjens, Denis; Sander, Christian; Scharf, Christian; Schettler, Hannes; Schleper, Peter; Schlieckau, Eike; Schmidt, Alexander; Schwandt, Joern; Sola, Valentina; Stadie, Hartmut; Steinbrück, Georg; Tholen, Heiner; Troendle, Daniel; Usai, Emanuele; Vanelderen, Lukas; Vanhoefer, Annika; Vormwald, Benedikt; Barth, Christian; Baur, Sebastian; Baus, Colin; Berger, Joram; Böser, Christian; Butz, Erik; Chwalek, Thorsten; Colombo, Fabio; De Boer, Wim; Descroix, Alexis; Dierlamm, Alexander; Fink, Simon; Frensch, Felix; Friese, Raphael; Giffels, Manuel; Gilbert, Andrew; Haitz, Dominik; Hartmann, Frank; Heindl, Stefan Michael; Husemann, Ulrich; Katkov, Igor; Kornmayer, Andreas; Lobelle Pardo, Patricia; Maier, Benedikt; Mildner, Hannes; Mozer, Matthias Ulrich; Müller, Thomas; Müller, Thomas; Plagge, Michael; Quast, Gunter; Rabbertz, Klaus; Röcker, Steffen; Roscher, Frank; Schröder, Matthias; Sieber, Georg; Simonis, Hans-Jürgen; Stober, Fred-Markus Helmut; Ulrich, Ralf; Wagner-Kuhr, Jeannine; Wayand, Stefan; Weber, Marc; Weiler, Thomas; Williamson, Shawn; Wöhrmann, Clemens; Wolf, Roger; Anagnostou, Georgios; Daskalakis, Georgios; Geralis, Theodoros; Giakoumopoulou, Viktoria Athina; Kyriakis, Aristotelis; Loukas, Demetrios; Psallidas, Andreas; Topsis-Giotis, Iasonas; Agapitos, Antonis; Kesisoglou, Stilianos; Panagiotou, Apostolos; Saoulidou, Niki; Tziaferi, Eirini; Evangelou, Ioannis; Flouris, Giannis; Foudas, Costas; Kokkas, Panagiotis; Loukas, Nikitas; Manthos, Nikolaos; Papadopoulos, Ioannis; Paradas, Evangelos; Strologas, John; Bencze, Gyorgy; Hajdu, Csaba; Hazi, Andras; Hidas, Pàl; Horvath, Dezso; Sikler, Ferenc; Veszpremi, Viktor; Vesztergombi, Gyorgy; Zsigmond, Anna Julia; Beni, Noemi; Czellar, Sandor; Karancsi, János; Molnar, Jozsef; Szillasi, Zoltan; Bartók, Márton; Makovec, Alajos; Raics, Peter; Trocsanyi, Zoltan Laszlo; Ujvari, Balazs; Choudhury, Somnath; Mal, Prolay; Mandal, Koushik; Sahoo, Deepak Kumar; Sahoo, Niladribihari; Swain, Sanjay Kumar; Bansal, Sunil; Beri, Suman Bala; Bhatnagar, Vipin; Chawla, Ridhi; Gupta, Ruchi; Bhawandeep, Bhawandeep; Kalsi, Amandeep Kaur; Kaur, Anterpreet; Kaur, Manjit; Kumar, Ramandeep; Mehta, Ankita; Mittal, Monika; Singh, Jasbir; Walia, Genius; Kumar, Ashok; Bhardwaj, Ashutosh; Choudhary, Brajesh C; Garg, Rocky Bala; Malhotra, Shivali; Naimuddin, Md; Nishu, Nishu; Ranjan, Kirti; Sharma, Ramkrishna; Sharma, Varun; Bhattacharya, Satyaki; Chatterjee, Kalyanmoy; Dey, Sourav; Dutta, Suchandra; Jain, Sandhya; Majumdar, Nayana; Modak, Atanu; Mondal, Kuntal; Mukhopadhyay, Supratik; Roy, Ashim; Roy, Debarati; Roy Chowdhury, Suvankar; Sarkar, Subir; Sharan, Manoj; Abdulsalam, Abdulla; Chudasama, Ruchi; Dutta, Dipanwita; Jha, Vishwajeet; Kumar, Vineet; Mohanty, Ajit Kumar; Pant, Lalit Mohan; Shukla, Prashant; Topkar, Anita; Aziz, Tariq; Banerjee, Sudeshna; Bhowmik, Sandeep; Chatterjee, Rajdeep Mohan; Dewanjee, Ram Krishna; Dugad, Shashikant; Ganguly, Sanmay; Ghosh, Saranya; Guchait, Monoranjan; Gurtu, Atul; Kole, Gouranga; Kumar, Sanjeev; Mahakud, Bibhuprasad; Maity, Manas; Majumder, Gobinda; Mazumdar, Kajari; Mitra, Soureek; Mohanty, Gagan Bihari; Parida, Bibhuti; Sarkar, Tanmay; Sur, Nairit; Sutar, Bajrang; Wickramage, Nadeesha; Chauhan, Shubhanshu; Dube, Sourabh; Kapoor, Anshul; Kothekar, Kunal; Sharma, Seema; Bakhshiansohi, Hamed; Behnamian, Hadi; Etesami, Seyed Mohsen; Fahim, Ali; Goldouzian, Reza; Khakzad, Mohsen; Mohammadi Najafabadi, Mojtaba; Naseri, Mohsen; Paktinat Mehdiabadi, Saeid; Rezaei Hosseinabadi, Ferdos; Safarzadeh, Batool; Zeinali, Maryam; Felcini, Marta; Grunewald, Martin; Abbrescia, Marcello; Calabria, Cesare; Caputo, Claudio; Colaleo, Anna; Creanza, Donato; Cristella, Leonardo; De Filippis, Nicola; De Palma, Mauro; Fiore, Luigi; Iaselli, Giuseppe; Maggi, Giorgio; Maggi, Marcello; Miniello, Giorgia; My, Salvatore; Nuzzo, Salvatore; Pompili, Alexis; Pugliese, Gabriella; Radogna, Raffaella; Ranieri, Antonio; Selvaggi, Giovanna; Silvestris, Lucia; Venditti, Rosamaria; Abbiendi, Giovanni; Battilana, Carlo; Benvenuti, Alberto; Bonacorsi, Daniele; Braibant-Giacomelli, Sylvie; Brigliadori, Luca; Campanini, Renato; Capiluppi, Paolo; Castro, Andrea; Cavallo, Francesca Romana; Chhibra, Simranjit Singh; Codispoti, Giuseppe; Cuffiani, Marco; Dallavalle, Gaetano-Marco; Fabbri, Fabrizio; Fanfani, Alessandra; Fasanella, Daniele; Giacomelli, Paolo; Grandi, Claudio; Guiducci, Luigi; Marcellini, Stefano; Masetti, Gianni; Montanari, Alessandro; Navarria, Francesco; Perrotta, Andrea; Rossi, Antonio; Rovelli, Tiziano; Siroli, Gian Piero; Tosi, Nicolò; Travaglini, Riccardo; Cappello, Gigi; Chiorboli, Massimiliano; Costa, Salvatore; Di Mattia, Alessandro; Giordano, Ferdinando; Potenza, Renato; Tricomi, Alessia; Tuve, Cristina; Barbagli, Giuseppe; Ciulli, Vitaliano; Civinini, Carlo; D'Alessandro, Raffaello; Focardi, Ettore; Gori, Valentina; Lenzi, Piergiulio; Meschini, Marco; Paoletti, Simone; Sguazzoni, Giacomo; Viliani, Lorenzo; Benussi, Luigi; Bianco, Stefano; Fabbri, Franco; Piccolo, Davide; Primavera, Federica; Calvelli, Valerio; Ferro, Fabrizio; Lo Vetere, Maurizio; Monge, Maria Roberta; Robutti, Enrico; Tosi, Silvano; Brianza, Luca; Dinardo, Mauro Emanuele; Fiorendi, Sara; Gennai, Simone; Gerosa, Raffaele; Ghezzi, Alessio; Govoni, Pietro; Malvezzi, Sandra; Manzoni, Riccardo Andrea; Marzocchi, Badder; Menasce, Dario; Moroni, Luigi; Paganoni, Marco; Pedrini, Daniele; Ragazzi, Stefano; Redaelli, Nicola; Tabarelli de Fatis, Tommaso; Buontempo, Salvatore; Cavallo, Nicola; Di Guida, Salvatore; Esposito, Marco; Fabozzi, Francesco; Iorio, Alberto Orso Maria; Lanza, Giuseppe; Lista, Luca; Meola, Sabino; Merola, Mario; Paolucci, Pierluigi; Sciacca, Crisostomo; Thyssen, Filip; Azzi, Patrizia; Bacchetta, Nicola; Benato, Lisa; Bisello, Dario; Boletti, Alessio; Branca, Antonio; Carlin, Roberto; Checchia, Paolo; Dall'Osso, Martino; Dorigo, Tommaso; Dosselli, Umberto; Gasparini, Fabrizio; Gasparini, Ugo; Gonella, Franco; Gozzelino, Andrea; Kanishchev, Konstantin; Lacaprara, Stefano; Margoni, Martino; Meneguzzo, Anna Teresa; Pazzini, Jacopo; Pozzobon, Nicola; Ronchese, Paolo; Simonetto, Franco; Torassa, Ezio; Tosi, Mia; Zanetti, Marco; Zotto, Pierluigi; Zucchetta, Alberto; Zumerle, Gianni; Braghieri, Alessandro; Magnani, Alice; Montagna, Paolo; Ratti, Sergio P; Re, Valerio; Riccardi, Cristina; Salvini, Paola; Vai, Ilaria; Vitulo, Paolo; Alunni Solestizi, Luisa; Bilei, Gian Mario; Ciangottini, Diego; Fanò, Livio; Lariccia, Paolo; Mantovani, Giancarlo; Menichelli, Mauro; Saha, Anirban; Santocchia, Attilio; Androsov, Konstantin; Azzurri, Paolo; Bagliesi, Giuseppe; Bernardini, Jacopo; Boccali, Tommaso; Castaldi, Rino; Ciocci, Maria Agnese; Dell'Orso, Roberto; Donato, Silvio; Fedi, Giacomo; Foà, Lorenzo; Giassi, Alessandro; Grippo, Maria Teresa; Ligabue, Franco; Lomtadze, Teimuraz; Martini, Luca; Messineo, Alberto; Palla, Fabrizio; Rizzi, Andrea; Savoy-Navarro, Aurore; Serban, Alin Titus; Spagnolo, Paolo; Tenchini, Roberto; Tonelli, Guido; Venturi, Andrea; Verdini, Piero Giorgio; Barone, Luciano; Cavallari, Francesca; D'imperio, Giulia; Del Re, Daniele; Diemoz, Marcella; Gelli, Simone; Jorda, Clara; Longo, Egidio; Margaroli, Fabrizio; Meridiani, Paolo; Organtini, Giovanni; Paramatti, Riccardo; Preiato, Federico; Rahatlou, Shahram; Rovelli, Chiara; Santanastasio, Francesco; Traczyk, Piotr; Amapane, Nicola; Arcidiacono, Roberta; Argiro, Stefano; Arneodo, Michele; Bellan, Riccardo; Biino, Cristina; Cartiglia, Nicolo; Costa, Marco; Covarelli, Roberto; Degano, Alessandro; Demaria, Natale; Finco, Linda; Kiani, Bilal; Mariotti, Chiara; Maselli, Silvia; Migliore, Ernesto; Monaco, Vincenzo; Monteil, Ennio; Obertino, Maria Margherita; Pacher, Luca; Pastrone, Nadia; Pelliccioni, Mario; Pinna Angioni, Gian Luca; Ravera, Fabio; Romero, Alessandra; Ruspa, Marta; Sacchi, Roberto; Solano, Ada; Staiano, Amedeo; Belforte, Stefano; Candelise, Vieri; Casarsa, Massimo; Cossutti, Fabio; Della Ricca, Giuseppe; Gobbo, Benigno; La Licata, Chiara; Marone, Matteo; Schizzi, Andrea; Zanetti, Anna; Kropivnitskaya, Anna; Nam, Soon-Kwon; Kim, Dong Hee; Kim, Gui Nyun; Kim, Min Suk; Kong, Dae Jung; Lee, Sangeun; Oh, Young Do; Sakharov, Alexandre; Son, Dong-Chul; Brochero Cifuentes, Javier Andres; Kim, Hyunsoo; Kim, Tae Jeong; Song, Sanghyeon; Choi, Suyong; Go, Yeonju; Gyun, Dooyeon; Hong, Byung-Sik; Kim, Hyunchul; Kim, Yongsun; Lee, Byounghoon; Lee, Kisoo; Lee, Kyong Sei; Lee, Songkyo; Park, Sung Keun; Roh, Youn; Yoo, Hwi Dong; Choi, Minkyoo; Kim, Hyunyong; Kim, Ji Hyun; Lee, Jason Sang Hun; Park, Inkyu; Ryu, Geonmo; Ryu, Min Sang; Choi, Young-Il; Goh, Junghwan; Kim, Donghyun; Kwon, Eunhyang; Lee, Jongseok; Yu, Intae; Dudenas, Vytautas; Juodagalvis, Andrius; Vaitkus, Juozas; Ahmed, Ijaz; Ibrahim, Zainol Abidin; Komaragiri, Jyothsna Rani; Md Ali, Mohd Adli Bin; Mohamad Idris, Faridah; Wan Abdullah, Wan Ahmad Tajuddin; Yusli, Mohd Nizam; Casimiro Linares, Edgar; Castilla-Valdez, Heriberto; De La Cruz-Burelo, Eduard; Heredia-De La Cruz, Ivan; Hernandez-Almada, Alberto; Lopez-Fernandez, Ricardo; Sánchez Hernández, Alberto; Carrillo Moreno, Salvador; Vazquez Valencia, Fabiola; Pedraza, Isabel; Salazar Ibarguen, Humberto Antonio; Morelos Pineda, Antonio; Krofcheck, David; Butler, Philip H; Ahmad, Ashfaq; Ahmad, Muhammad; Hassan, Qamar; Hoorani, Hafeez R; Khan, Wajid Ali; Khurshid, Taimoor; Shoaib, Muhammad; Bialkowska, Helena; Bluj, Michal; Boimska, Bożena; Frueboes, Tomasz; Górski, Maciej; Kazana, Malgorzata; Nawrocki, Krzysztof; Romanowska-Rybinska, Katarzyna; Szleper, Michal; Zalewski, Piotr; Brona, Grzegorz; Bunkowski, Karol; Byszuk, Adrian; Doroba, Krzysztof; Kalinowski, Artur; Konecki, Marcin; Krolikowski, Jan; Misiura, Maciej; Olszewski, Michal; Walczak, Marek; Bargassa, Pedrame; Beirão Da Cruz E Silva, Cristóvão; Di Francesco, Agostino; Faccioli, Pietro; Ferreira Parracho, Pedro Guilherme; Gallinaro, Michele; Leonardo, Nuno; Lloret Iglesias, Lara; Nguyen, Federico; Rodrigues Antunes, Joao; Seixas, Joao; Toldaiev, Oleksii; Vadruccio, Daniele; Varela, Joao; Vischia, Pietro; Afanasiev, Serguei; Bunin, Pavel; Gavrilenko, Mikhail; Golutvin, Igor; Gorbunov, Ilya; Kamenev, Alexey; Karjavin, Vladimir; Lanev, Alexander; Malakhov, Alexander; Matveev, Viktor; Moisenz, Petr; Palichik, Vladimir; Perelygin, Victor; Shmatov, Sergey; Shulha, Siarhei; Skatchkov, Nikolai; Smirnov, Vitaly; Zarubin, Anatoli; Golovtsov, Victor; Ivanov, Yury; Kim, Victor; Kuznetsova, Ekaterina; Levchenko, Petr; Murzin, Victor; Oreshkin, Vadim; Smirnov, Igor; Sulimov, Valentin; Uvarov, Lev; Vavilov, Sergey; Vorobyev, Alexey; Andreev, Yuri; Dermenev, Alexander; Gninenko, Sergei; Golubev, Nikolai; Karneyeu, Anton; Kirsanov, Mikhail; Krasnikov, Nikolai; Pashenkov, Anatoli; Tlisov, Danila; Toropin, Alexander; Epshteyn, Vladimir; Gavrilov, Vladimir; Lychkovskaya, Natalia; Popov, Vladimir; Pozdnyakov, Ivan; Safronov, Grigory; Spiridonov, Alexander; Vlasov, Evgueni; Zhokin, Alexander; Bylinkin, Alexander; Andreev, Vladimir; Azarkin, Maksim; Dremin, Igor; Kirakosyan, Martin; Leonidov, Andrey; Mesyats, Gennady; Rusakov, Sergey V; Baskakov, Alexey; Belyaev, Andrey; Boos, Edouard; Ershov, Alexander; Gribushin, Andrey; Khein, Lev; Klyukhin, Vyacheslav; Kodolova, Olga; Lokhtin, Igor; Lukina, Olga; Miagkov, Igor; Obraztsov, Stepan; Petrushanko, Sergey; Savrin, Viktor; Snigirev, Alexander; Azhgirey, Igor; Bayshev, Igor; Bitioukov, Sergei; Kachanov, Vassili; Kalinin, Alexey; Konstantinov, Dmitri; Krychkine, Victor; Petrov, Vladimir; Ryutin, Roman; Sobol, Andrei; Tourtchanovitch, Leonid; Troshin, Sergey; Tyurin, Nikolay; Uzunian, Andrey; Volkov, Alexey; Adzic, Petar; Cirkovic, Predrag; Milosevic, Jovan; Rekovic, Vladimir; Alcaraz Maestre, Juan; Calvo, Enrique; Cerrada, Marcos; Chamizo Llatas, Maria; Colino, Nicanor; De La Cruz, Begona; Delgado Peris, Antonio; Escalante Del Valle, Alberto; Fernandez Bedoya, Cristina; Fernández Ramos, Juan Pablo; Flix, Jose; Fouz, Maria Cruz; Garcia-Abia, Pablo; Gonzalez Lopez, Oscar; Goy Lopez, Silvia; Hernandez, Jose M; Josa, Maria Isabel; Navarro De Martino, Eduardo; Pérez-Calero Yzquierdo, Antonio María; Puerta Pelayo, Jesus; Quintario Olmeda, Adrián; Redondo, Ignacio; Romero, Luciano; Santaolalla, Javier; Senghi Soares, Mara; Albajar, Carmen; de Trocóniz, Jorge F; Missiroli, Marino; Moran, Dermot; Cuevas, Javier; Fernandez Menendez, Javier; Folgueras, Santiago; Gonzalez Caballero, Isidro; Palencia Cortezon, Enrique; Vizan Garcia, Jesus Manuel; Cabrillo, Iban Jose; Calderon, Alicia; Castiñeiras De Saa, Juan Ramon; De Castro Manzano, Pablo; Fernandez, Marcos; Garcia-Ferrero, Juan; Gomez, Gervasio; Lopez Virto, Amparo; Marco, Jesus; Marco, Rafael; Martinez Rivero, Celso; Matorras, Francisco; Piedra Gomez, Jonatan; Rodrigo, Teresa; Rodríguez-Marrero, Ana Yaiza; Ruiz-Jimeno, Alberto; Scodellaro, Luca; Trevisani, Nicolò; Vila, Ivan; Vilar Cortabitarte, Rocio; Abbaneo, Duccio; Auffray, Etiennette; Auzinger, Georg; Bachtis, Michail; Baillon, Paul; Ball, Austin; Barney, David; Benaglia, Andrea; Bendavid, Joshua; Benhabib, Lamia; Benitez, Jose F; Berruti, Gaia Maria; Bloch, Philippe; Bocci, Andrea; Bonato, Alessio; Botta, Cristina; Breuker, Horst; Camporesi, Tiziano; Castello, Roberto; Cerminara, Gianluca; D'Alfonso, Mariarosaria; D'Enterria, David; Dabrowski, Anne; Daponte, Vincenzo; David Tinoco Mendes, Andre; De Gruttola, Michele; De Guio, Federico; De Roeck, Albert; De Visscher, Simon; Di Marco, Emanuele; Dobson, Marc; Dordevic, Milos; Dorney, Brian; Du Pree, Tristan; Duggan, Daniel; Dünser, Marc; Dupont, Niels; Elliott-Peisert, Anna; Franzoni, Giovanni; Fulcher, Jonathan; Funk, Wolfgang; Gigi, Dominique; Gill, Karl; Giordano, Domenico; Girone, Maria; Glege, Frank; Guida, Roberto; Gundacker, Stefan; Guthoff, Moritz; Hammer, Josef; Harris, Philip; Hegeman, Jeroen; Innocente, Vincenzo; Janot, Patrick; Kirschenmann, Henning; Kortelainen, Matti J; Kousouris, Konstantinos; Krajczar, Krisztian; Lecoq, Paul; Lourenco, Carlos; Lucchini, Marco Toliman; Magini, Nicolo; Malgeri, Luca; Mannelli, Marcello; Martelli, Arabella; Masetti, Lorenzo; Meijers, Frans; Mersi, Stefano; Meschi, Emilio; Moortgat, Filip; Morovic, Srecko; Mulders, Martijn; Nemallapudi, Mythra Varun; Neugebauer, Hannes; Orfanelli, Styliani; Orsini, Luciano; Pape, Luc; Perez, Emmanuelle; Peruzzi, Marco; Petrilli, Achille; Petrucciani, Giovanni; Pfeiffer, Andreas; Pierini, Maurizio; Piparo, Danilo; Racz, Attila; Reis, Thomas; Rolandi, Gigi; Rovere, Marco; Ruan, Manqi; Sakulin, Hannes; Schäfer, Christoph; Schwick, Christoph; Seidel, Markus; Sharma, Archana; Silva, Pedro; Simon, Michal; Sphicas, Paraskevas; Steggemann, Jan; Stieger, Benjamin; Stoye, Markus; Takahashi, Yuta; Treille, Daniel; Triossi, Andrea; Tsirou, Andromachi; Veres, Gabor Istvan; Wardle, Nicholas; Wöhri, Hermine Katharina; Zagoździńska, Agnieszka; Zeuner, Wolfram Dietrich; Bertl, Willi; Deiters, Konrad; Erdmann, Wolfram; Horisberger, Roland; Ingram, Quentin; Kaestli, Hans-Christian; Kotlinski, Danek; Langenegger, Urs; Renker, Dieter; Rohe, Tilman; Bachmair, Felix; Bäni, Lukas; Bianchini, Lorenzo; Casal, Bruno; Dissertori, Günther; Dittmar, Michael; Donegà, Mauro; Eller, Philipp; Grab, Christoph; Heidegger, Constantin; Hits, Dmitry; Hoss, Jan; Kasieczka, Gregor; Lustermann, Werner; Mangano, Boris; Marionneau, Matthieu; Martinez Ruiz del Arbol, Pablo; Masciovecchio, Mario; Meister, Daniel; Micheli, Francesco; Musella, Pasquale; Nessi-Tedaldi, Francesca; Pandolfi, Francesco; Pata, Joosep; Pauss, Felicitas; Perrozzi, Luca; Quittnat, Milena; Rossini, Marco; Schönenberger, Myriam; Starodumov, Andrei; Takahashi, Maiko; Tavolaro, Vittorio Raoul; Theofilatos, Konstantinos; Wallny, Rainer; Aarrestad, Thea Klaeboe; Amsler, Claude; Caminada, Lea; Canelli, Maria Florencia; Chiochia, Vincenzo; De Cosa, Annapaola; Galloni, Camilla; Hinzmann, Andreas; Hreus, Tomas; Kilminster, Benjamin; Lange, Clemens; Ngadiuba, Jennifer; Pinna, Deborah; Rauco, Giorgia; Robmann, Peter; Ronga, Frederic Jean; Salerno, Daniel; Yang, Yong; Cardaci, Marco; Chen, Kuan-Hsin; Doan, Thi Hien; Jain, Shilpi; Khurana, Raman; Konyushikhin, Maxim; Kuo, Chia-Ming; Lin, Willis; Lu, Yun-Ju; Pozdnyakov, Andrey; Yu, Shin-Shan; Kumar, Arun; Bartek, Rachel; Chang, Paoti; Chang, You-Hao; Chang, Yu-Wei; Chao, Yuan; Chen, Kai-Feng; Chen, Po-Hsun; Dietz, Charles; Fiori, Francesco; Grundler, Ulysses; Hou, George Wei-Shu; Hsiung, Yee; Liu, Yueh-Feng; Lu, Rong-Shyang; Miñano Moya, Mercedes; Petrakou, Eleni; Tsai, Jui-fa; Tzeng, Yeng-Ming; Asavapibhop, Burin; Kovitanggoon, Kittikul; Singh, Gurpreet; Srimanobhas, Norraphat; Suwonjandee, Narumon; Adiguzel, Aytul; Cerci, Salim; Demiroglu, Zuhal Seyma; Dozen, Candan; Dumanoglu, Isa; Gecit, Fehime Hayal; Girgis, Semiray; Gokbulut, Gul; Guler, Yalcin; Gurpinar, Emine; Hos, Ilknur; Kangal, Evrim Ersin; Kayis Topaksu, Aysel; Onengut, Gulsen; Ozcan, Merve; Ozdemir, Kadri; Ozturk, Sertac; Tali, Bayram; Topakli, Huseyin; Vergili, Mehmet; Zorbilmez, Caglar; Akin, Ilina Vasileva; Bilin, Bugra; Bilmis, Selcuk; Isildak, Bora; Karapinar, Guler; Yalvac, Metin; Zeyrek, Mehmet; Gülmez, Erhan; Kaya, Mithat; Kaya, Ozlem; Yetkin, Elif Asli; Yetkin, Taylan; Cakir, Altan; Cankocak, Kerem; Sen, Sercan; Vardarlı, Fuat Ilkehan; Grynyov, Boris; Levchuk, Leonid; Sorokin, Pavel; Aggleton, Robin; Ball, Fionn; Beck, Lana; Brooke, James John; Clement, Emyr; Cussans, David; Flacher, Henning; Goldstein, Joel; Grimes, Mark; Heath, Greg P; Heath, Helen F; Jacob, Jeson; Kreczko, Lukasz; Lucas, Chris; Meng, Zhaoxia; Newbold, Dave M; Paramesvaran, Sudarshan; Poll, Anthony; Sakuma, Tai; Seif El Nasr-storey, Sarah; Senkin, Sergey; Smith, Dominic; Smith, Vincent J; Bell, Ken W; Belyaev, Alexander; Brew, Christopher; Brown, Robert M; Calligaris, Luigi; Cieri, Davide; Cockerill, David JA; Coughlan, John A; Harder, Kristian; Harper, Sam; Olaiya, Emmanuel; Petyt, David; Shepherd-Themistocleous, Claire; Thea, Alessandro; Tomalin, Ian R; Williams, Thomas; Worm, Steven; Baber, Mark; Bainbridge, Robert; Buchmuller, Oliver; Bundock, Aaron; Burton, Darren; Casasso, Stefano; Citron, Matthew; Colling, David; Corpe, Louie; Dauncey, Paul; Davies, Gavin; De Wit, Adinda; Della Negra, Michel; Dunne, Patrick; Elwood, Adam; Futyan, David; Hall, Geoffrey; Iles, Gregory; Lane, Rebecca; Lucas, Robyn; Lyons, Louis; Magnan, Anne-Marie; Malik, Sarah; Nash, Jordan; Nikitenko, Alexander; Pela, Joao; Pesaresi, Mark; Petridis, Konstantinos; Raymond, David Mark; Richards, Alexander; Rose, Andrew; Seez, Christopher; Tapper, Alexander; Uchida, Kirika; Vazquez Acosta, Monica; Virdee, Tejinder; Zenz, Seth Conrad; Cole, Joanne; Hobson, Peter R; Khan, Akram; Kyberd, Paul; Leggat, Duncan; Leslie, Dawn; Reid, Ivan; Symonds, Philip; Teodorescu, Liliana; Turner, Mark; Borzou, Ahmad; Call, Kenneth; Dittmann, Jay; Hatakeyama, Kenichi; Liu, Hongxuan; Pastika, Nathaniel; Charaf, Otman; Cooper, Seth; Henderson, Conor; Rumerio, Paolo; Arcaro, Daniel; Avetisyan, Aram; Bose, Tulika; Fantasia, Cory; Gastler, Daniel; Lawson, Philip; Rankin, Dylan; Richardson, Clint; Rohlf, James; St John, Jason; Sulak, Lawrence; Zou, David; Alimena, Juliette; Berry, Edmund; Cutts, David; Ferapontov, Alexey; Garabedian, Alex; Hakala, John; Heintz, Ulrich; Laird, Edward; Landsberg, Greg; Mao, Zaixing; Narain, Meenakshi; Piperov, Stefan; Sagir, Sinan; Syarif, Rizki; Breedon, Richard; Breto, Guillermo; Calderon De La Barca Sanchez, Manuel; Chauhan, Sushil; Chertok, Maxwell; Conway, John; Conway, Rylan; Cox, Peter Timothy; Erbacher, Robin; Funk, Garrett; Gardner, Michael; Ko, Winston; Lander, Richard; Mclean, Christine; Mulhearn, Michael; Pellett, Dave; Pilot, Justin; Ricci-Tam, Francesca; Shalhout, Shalhout; Smith, John; Squires, Michael; Stolp, Dustin; Tripathi, Mani; Wilbur, Scott; Yohay, Rachel; Cousins, Robert; Everaerts, Pieter; Florent, Alice; Hauser, Jay; Ignatenko, Mikhail; Saltzberg, David; Takasugi, Eric; Valuev, Vyacheslav; Weber, Matthias; Burt, Kira; Clare, Robert; Ellison, John Anthony; Gary, J William; Hanson, Gail; Heilman, Jesse; Ivova PANEVA, Mirena; Jandir, Pawandeep; Kennedy, Elizabeth; Lacroix, Florent; Long, Owen Rosser; Luthra, Arun; Malberti, Martina; Olmedo Negrete, Manuel; Shrinivas, Amithabh; Wei, Hua; Wimpenny, Stephen; Yates, Brent; Branson, James G; Cerati, Giuseppe Benedetto; Cittolin, Sergio; D'Agnolo, Raffaele Tito; Derdzinski, Mark; Holzner, André; Kelley, Ryan; Klein, Daniel; Letts, James; Macneill, Ian; Olivito, Dominick; Padhi, Sanjay; Pieri, Marco; Sani, Matteo; Sharma, Vivek; Simon, Sean; Tadel, Matevz; Vartak, Adish; Wasserbaech, Steven; Welke, Charles; Würthwein, Frank; Yagil, Avraham; Zevi Della Porta, Giovanni; Bradmiller-Feld, John; Campagnari, Claudio; Dishaw, Adam; Dutta, Valentina; Flowers, Kristen; Franco Sevilla, Manuel; Geffert, Paul; George, Christopher; Golf, Frank; Gouskos, Loukas; Gran, Jason; Incandela, Joe; Mccoll, Nickolas; Mullin, Sam Daniel; Richman, Jeffrey; Stuart, David; Suarez, Indara; West, Christopher; Yoo, Jaehyeok; Anderson, Dustin; Apresyan, Artur; Bornheim, Adolf; Bunn, Julian; Chen, Yi; Duarte, Javier; Mott, Alexander; Newman, Harvey B; Pena, Cristian; Spiropulu, Maria; Vlimant, Jean-Roch; Xie, Si; Zhu, Ren-Yuan; Andrews, Michael Benjamin; Azzolini, Virginia; Calamba, Aristotle; Carlson, Benjamin; Ferguson, Thomas; Paulini, Manfred; Russ, James; Sun, Menglei; Vogel, Helmut; Vorobiev, Igor; Cumalat, John Perry; Ford, William T; Gaz, Alessandro; Jensen, Frank; Johnson, Andrew; Krohn, Michael; Mulholland, Troy; Nauenberg, Uriel; Stenson, Kevin; Wagner, Stephen Robert; Alexander, James; Chatterjee, Avishek; Chaves, Jorge; Chu, Jennifer; Dittmer, Susan; Eggert, Nicholas; Mirman, Nathan; Nicolas Kaufman, Gala; Patterson, Juliet Ritchie; Rinkevicius, Aurelijus; Ryd, Anders; Skinnari, Louise; Soffi, Livia; Sun, Werner; Tan, Shao Min; Teo, Wee Don; Thom, Julia; Thompson, Joshua; Tucker, Jordan; Weng, Yao; Wittich, Peter; Abdullin, Salavat; Albrow, Michael; Apollinari, Giorgio; Banerjee, Sunanda; Bauerdick, Lothar AT; Beretvas, Andrew; Berryhill, Jeffrey; Bhat, Pushpalatha C; Bolla, Gino; Burkett, Kevin; Butler, Joel Nathan; Cheung, Harry; Chlebana, Frank; Cihangir, Selcuk; Elvira, Victor Daniel; Fisk, Ian; Freeman, Jim; Gottschalk, Erik; Gray, Lindsey; Green, Dan; Grünendahl, Stefan; Gutsche, Oliver; Hanlon, Jim; Hare, Daryl; Harris, Robert M; Hasegawa, Satoshi; Hirschauer, James; Hu, Zhen; Jayatilaka, Bodhitha; Jindariani, Sergo; Johnson, Marvin; Joshi, Umesh; Klima, Boaz; Kreis, Benjamin; Lammel, Stephan; Linacre, Jacob; Lincoln, Don; Lipton, Ron; Liu, Tiehui; Lopes De Sá, Rafael; Lykken, Joseph; Maeshima, Kaori; Marraffino, John Michael; Maruyama, Sho; Mason, David; McBride, Patricia; Merkel, Petra; Mrenna, Stephen; Nahn, Steve; Newman-Holmes, Catherine; O'Dell, Vivian; Pedro, Kevin; Prokofyev, Oleg; Rakness, Gregory; Sexton-Kennedy, Elizabeth; Soha, Aron; Spalding, William J; Spiegel, Leonard; Strobbe, Nadja; Taylor, Lucas; Tkaczyk, Slawek; Tran, Nhan Viet; Uplegger, Lorenzo; Vaandering, Eric Wayne; Vernieri, Caterina; Verzocchi, Marco; Vidal, Richard; Weber, Hannsjoerg Artur; Whitbeck, Andrew; Acosta, Darin; Avery, Paul; Bortignon, Pierluigi; Bourilkov, Dimitri; Carnes, Andrew; Carver, Matthew; Curry, David; Das, Souvik; Field, Richard D; Furic, Ivan-Kresimir; Gleyzer, Sergei V; Konigsberg, Jacobo; Korytov, Andrey; Kotov, Khristian; Ma, Peisen; Matchev, Konstantin; Mei, Hualin; Milenovic, Predrag; Mitselmakher, Guenakh; Rank, Douglas; Rossin, Roberto; Shchutska, Lesya; Snowball, Matthew; Sperka, David; Terentyev, Nikolay; Thomas, Laurent; Wang, Jian; Wang, Sean-Jiun; Yelton, John; Hewamanage, Samantha; Linn, Stephan; Markowitz, Pete; Martinez, German; Rodriguez, Jorge Luis; Ackert, Andrew; Adams, Jordon Rowe; Adams, Todd; Askew, Andrew; Bein, Samuel; Bochenek, Joseph; Diamond, Brendan; Haas, Jeff; Hagopian, Sharon; Hagopian, Vasken; Johnson, Kurtis F; Khatiwada, Ajeeta; Prosper, Harrison; Weinberg, Marc; Baarmand, Marc M; Bhopatkar, Vallary; Colafranceschi, Stefano; Hohlmann, Marcus; Kalakhety, Himali; Noonan, Daniel; Roy, Titas; Yumiceva, Francisco; Adams, Mark Raymond; Apanasevich, Leonard; Berry, Douglas; Betts, Russell Richard; Bucinskaite, Inga; Cavanaugh, Richard; Evdokimov, Olga; Gauthier, Lucie; Gerber, Cecilia Elena; Hofman, David Jonathan; Kurt, Pelin; O'Brien, Christine; Sandoval Gonzalez, Irving Daniel; Turner, Paul; Varelas, Nikos; Wu, Zhenbin; Zakaria, Mohammed; Bilki, Burak; Clarida, Warren; Dilsiz, Kamuran; Durgut, Süleyman; Gandrajula, Reddy Pratap; Haytmyradov, Maksat; Khristenko, Viktor; Merlo, Jean-Pierre; Mermerkaya, Hamit; Mestvirishvili, Alexi; Moeller, Anthony; Nachtman, Jane; Ogul, Hasan; Onel, Yasar; Ozok, Ferhat; Penzo, Aldo; Snyder, Christina; Tiras, Emrah; Wetzel, James; Yi, Kai; Anderson, Ian; Barnett, Bruce Arnold; Blumenfeld, Barry; Eminizer, Nicholas; Fehling, David; Feng, Lei; Gritsan, Andrei; Maksimovic, Petar; Martin, Christopher; Osherson, Marc; Roskes, Jeffrey; Cocoros, Alice; Sarica, Ulascan; Swartz, Morris; Xiao, Meng; Xin, Yongjie; You, Can; Baringer, Philip; Bean, Alice; Benelli, Gabriele; Bruner, Christopher; Kenny III, Raymond Patrick; Majumder, Devdatta; Malek, Magdalena; Murray, Michael; Sanders, Stephen; Stringer, Robert; Wang, Quan; Ivanov, Andrew; Kaadze, Ketino; Khalil, Sadia; Makouski, Mikhail; Maravin, Yurii; Mohammadi, Abdollah; Saini, Lovedeep Kaur; Skhirtladze, Nikoloz; Toda, Sachiko; Lange, David; Rebassoo, Finn; Wright, Douglas; Anelli, Christopher; Baden, Drew; Baron, Owen; Belloni, Alberto; Calvert, Brian; Eno, Sarah Catherine; Ferraioli, Charles; Gomez, Jaime; Hadley, Nicholas John; Jabeen, Shabnam; Kellogg, Richard G; Kolberg, Ted; Kunkle, Joshua; Lu, Ying; Mignerey, Alice; Shin, Young Ho; Skuja, Andris; Tonjes, Marguerite; Tonwar, Suresh C; Apyan, Aram; Barbieri, Richard; Baty, Austin; Bierwagen, Katharina; Brandt, Stephanie; Busza, Wit; Cali, Ivan Amos; Demiragli, Zeynep; Di Matteo, Leonardo; Gomez Ceballos, Guillelmo; Goncharov, Maxim; Gulhan, Doga; Iiyama, Yutaro; Innocenti, Gian Michele; Klute, Markus; Kovalskyi, Dmytro; Lai, Yue Shi; Lee, Yen-Jie; Levin, Andrew; Luckey, Paul David; Marini, Andrea Carlo; Mcginn, Christopher; Mironov, Camelia; Narayanan, Siddharth; Niu, Xinmei; Paus, Christoph; Roland, Christof; Roland, Gunther; Salfeld-Nebgen, Jakob; Stephans, George; Sumorok, Konstanty; Varma, Mukund; Velicanu, Dragos; Veverka, Jan; Wang, Jing; Wang, Ta-Wei; Wyslouch, Bolek; Yang, Mingming; Zhukova, Victoria; Dahmes, Bryan; Evans, Andrew; Finkel, Alexey; Gude, Alexander; Hansen, Peter; Kalafut, Sean; Kao, Shih-Chuan; Klapoetke, Kevin; Kubota, Yuichi; Lesko, Zachary; Mans, Jeremy; Nourbakhsh, Shervin; Ruckstuhl, Nicole; Rusack, Roger; Tambe, Norbert; Turkewitz, Jared; Acosta, John Gabriel; Oliveros, Sandra; Avdeeva, Ekaterina; Bloom, Kenneth; Bose, Suvadeep; Claes, Daniel R; Dominguez, Aaron; Fangmeier, Caleb; Gonzalez Suarez, Rebeca; Kamalieddin, Rami; Knowlton, Dan; Kravchenko, Ilya; Meier, Frank; Monroy, Jose; Ratnikov, Fedor; Siado, Joaquin Emilo; Snow, Gregory R; Alyari, Maral; Dolen, James; George, Jimin; Godshalk, Andrew; Harrington, Charles; Iashvili, Ia; Kaisen, Josh; Kharchilava, Avto; Kumar, Ashish; Rappoccio, Salvatore; Roozbahani, Bahareh; Alverson, George; Barberis, Emanuela; Baumgartel, Darin; Chasco, Matthew; Hortiangtham, Apichart; Massironi, Andrea; Morse, David Michael; Nash, David; Orimoto, Toyoko; Teixeira De Lima, Rafael; Trocino, Daniele; Wang, Ren-Jie; Wood, Darien; Zhang, Jinzhong; Bhattacharya, Saptaparna; Hahn, Kristan Allan; Kubik, Andrew; Low, Jia Fu; Mucia, Nicholas; Odell, Nathaniel; Pollack, Brian; Schmitt, Michael Henry; Stoynev, Stoyan; Sung, Kevin; Trovato, Marco; Velasco, Mayda; Brinkerhoff, Andrew; Dev, Nabarun; Hildreth, Michael; Jessop, Colin; Karmgard, Daniel John; Kellams, Nathan; Lannon, Kevin; Marinelli, Nancy; Meng, Fanbo; Mueller, Charles; Musienko, Yuri; Planer, Michael; Reinsvold, Allison; Ruchti, Randy; Smith, Geoffrey; Taroni, Silvia; Valls, Nil; Wayne, Mitchell; Wolf, Matthias; Woodard, Anna; Antonelli, Louis; Brinson, Jessica; Bylsma, Ben; Durkin, Lloyd Stanley; Flowers, Sean; Hart, Andrew; Hill, Christopher; Hughes, Richard; Ji, Weifeng; Ling, Ta-Yung; Liu, Bingxuan; Luo, Wuming; Puigh, Darren; Rodenburg, Marissa; Winer, Brian L; Wulsin, Howard Wells; Driga, Olga; Elmer, Peter; Hardenbrook, Joshua; Hebda, Philip; Koay, Sue Ann; Lujan, Paul; Marlow, Daniel; Medvedeva, Tatiana; Mooney, Michael; Olsen, James; Palmer, Christopher; Piroué, Pierre; Saka, Halil; Stickland, David; Tully, Christopher; Zuranski, Andrzej; Malik, Sudhir; Barker, Anthony; Barnes, Virgil E; Benedetti, Daniele; Bortoletto, Daniela; Gutay, Laszlo; Jha, Manoj; Jones, Matthew; Jung, Andreas Werner; Jung, Kurt; Kumar, Ajay; Miller, David Harry; Neumeister, Norbert; Radburn-Smith, Benjamin Charles; Shi, Xin; Shipsey, Ian; Silvers, David; Sun, Jian; Svyatkovskiy, Alexey; Wang, Fuqiang; Xie, Wei; Xu, Lingshan; Parashar, Neeti; Stupak, John; Adair, Antony; Akgun, Bora; Chen, Zhenyu; Ecklund, Karl Matthew; Geurts, Frank JM; Guilbaud, Maxime; Li, Wei; Michlin, Benjamin; Northup, Michael; Padley, Brian Paul; Redjimi, Radia; Roberts, Jay; Rorie, Jamal; Tu, Zhoudunming; Zabel, James; Betchart, Burton; Bodek, Arie; de Barbaro, Pawel; Demina, Regina; Eshaq, Yossof; Ferbel, Thomas; Galanti, Mario; Garcia-Bellido, Aran; Han, Jiyeon; Harel, Amnon; Hindrichs, Otto; Khukhunaishvili, Aleko; Petrillo, Gianluca; Tan, Ping; Verzetti, Mauro; Arora, Sanjay; Chou, John Paul; Contreras-Campana, Christian; Contreras-Campana, Emmanuel; Ferencek, Dinko; Gershtein, Yuri; Gray, Richard; Halkiadakis, Eva; Hidas, Dean; Hughes, Elliot; Kaplan, Steven; Kunnawalkam Elayavalli, Raghav; Lath, Amitabh; Nash, Kevin; Panwalkar, Shruti; Park, Michael; Salur, Sevil; Schnetzer, Steve; Sheffield, David; Somalwar, Sunil; Stone, Robert; Thomas, Scott; Thomassen, Peter; Walker, Matthew; Foerster, Mark; Riley, Grant; Rose, Keith; Spanier, Stefan; Bouhali, Othmane; Castaneda Hernandez, Alfredo; Celik, Ali; Dalchenko, Mykhailo; De Mattia, Marco; Delgado, Andrea; Dildick, Sven; Eusebi, Ricardo; Gilmore, Jason; Huang, Tao; Kamon, Teruki; Krutelyov, Vyacheslav; Mueller, Ryan; Osipenkov, Ilya; Pakhotin, Yuriy; Patel, Rishi; Perloff, Alexx; Rose, Anthony; Safonov, Alexei; Tatarinov, Aysen; Ulmer, Keith; Akchurin, Nural; Cowden, Christopher; Damgov, Jordan; Dragoiu, Cosmin; Dudero, Phillip Russell; Faulkner, James; Kunori, Shuichi; Lamichhane, Kamal; Lee, Sung Won; Libeiro, Terence; Undleeb, Sonaina; Volobouev, Igor; Appelt, Eric; Delannoy, Andrés G; Greene, Senta; Gurrola, Alfredo; Janjam, Ravi; Johns, Willard; Maguire, Charles; Mao, Yaxian; Melo, Andrew; Ni, Hong; Sheldon, Paul; Tuo, Shengquan; Velkovska, Julia; Xu, Qiao; Arenton, Michael Wayne; Cox, Bradley; Francis, Brian; Goodell, Joseph; Hirosky, Robert; Ledovskoy, Alexander; Li, Hengne; Lin, Chuanzhe; Neu, Christopher; Sinthuprasith, Tutanon; Sun, Xin; Wang, Yanchu; Wolfe, Evan; Wood, John; Xia, Fan; Clarke, Christopher; Harr, Robert; Karchin, Paul Edmund; Kottachchi Kankanamge Don, Chamath; Lamichhane, Pramod; Sturdy, Jared; Belknap, Donald; Carlsmith, Duncan; Cepeda, Maria; Dasu, Sridhara; Dodd, Laura; Duric, Senka; Gomber, Bhawna; Grothe, Monika; Hall-Wilton, Richard; Herndon, Matthew; Hervé, Alain; Klabbers, Pamela; Lanaro, Armando; Levine, Aaron; Long, Kenneth; Loveless, Richard; Mohapatra, Ajit; Ojalvo, Isabel; Perry, Thomas; Pierro, Giuseppe Antonio; Polese, Giovanni; Ruggles, Tyler; Sarangi, Tapas; Savin, Alexander; Sharma, Archana; Smith, Nicholas; Smith, Wesley H; Taylor, Devin; Verwilligen, Piet; Woods, Nathaniel

    2016-04-27

    Results on two-particle angular correlations for charged particles produced in pp collisions at a center-of-mass energy of 13 TeV are presented. The data were taken with the CMS detector at the LHC and correspond to an integrated luminosity of about 270 inverse-nanobarns. The correlations are studied over a broad range of pseudo rapidity (|$ \\eta $| 2.0), near-side ($\\Delta\\phi\\approx$ 0) structure emerges in the two-particle $\\Delta\\eta$-$\\Delta\\phi$ correlation functions. The magnitude of the correlation exhibits a pronounced maximum in the range 1.0 < $p_{\\mathrm{T}}$ < 2.0 GeV/$c$ and an approximately linear increase with the charged particle multiplicity. The overall correlation strength at $\\sqrt{s} =$ 13TeV is similar to that found in earlier pp data at $\\sqrt{s} =$ 7 TeV, but is measured up to much higher multiplicity values. The observed long-range correlations are compared to those seen in pp, pPb, and PbPb collisions at lower collision energies.

  13. Profiting from Probability; Combining Low and High Probability Isotopes as a Tool Extending the Dynamic Range of an Assay Measuring Amphetamine and Methamphetamine in Urine.

    Science.gov (United States)

    Miller, Anna M; Goggin, Melissa M; Nguyen, An; Gozum, Stephanie D; Janis, Gregory C

    2017-06-01

    A wide range of concentrations are frequently observed when measuring drugs of abuse in urine toxicology samples; this is especially true for amphetamine and methamphetamine. Routine liquid chromatography-tandem mass spectrometry confirmatory methods commonly anchored at a 50 ng/mL lower limit of quantitation can span approximately a 100-fold concentration range before regions of non-linearity are reached deteriorating accurate quantitation and qualitative assessments. In our experience, approximately a quarter of amphetamine and methamphetamine positive samples are above a 5,000 ng/mL upper limit of quantitation and thus require reanalysis with dilution for accurate quantitative and acceptable qualitative results. We present here the development of an analytical method capable of accurately quantifying samples with concentrations spanning several orders of magnitude without the need for sample dilution and reanalysis. For each analyte the major isotopes were monitored for analysis through the lower concentration ranges (50-5,000 ng/mL), and the naturally occurring, low probability 13C2 isotopes were monitored for the analysis of the high concentration samples (5,000-100,000 ng/mL amphetamine and 5,000-200,000 ng/mL methamphetamine). The method simultaneously monitors transitions for the molecules containing only 12C and 13C2 isotopologues eliminating the need for re-extraction and reanalysis of high concentration samples. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  14. Towards direct realisation of the SI unit of sound pressure in the audible hearing range based on optical free-field acoustic particle measurements

    Energy Technology Data Exchange (ETDEWEB)

    Koukoulas, Triantafillos, E-mail: triantafillos.koukoulas@npl.co.uk; Piper, Ben [Acoustics Group, National Physical Laboratory, Hampton Road, Teddington, Middlesex TW11 0LW (United Kingdom)

    2015-04-20

    Since the introduction of the International System of Units (the SI system) in 1960, weights, measures, standardised approaches, procedures, and protocols have been introduced, adapted, and extensively used. A major international effort and activity concentrate on the definition and traceability of the seven base SI units in terms of fundamental constants, and consequently those units that are derived from the base units. In airborne acoustical metrology and for the audible range of frequencies up to 20 kHz, the SI unit of sound pressure, the pascal, is realised indirectly and without any knowledge or measurement of the sound field. Though the principle of reciprocity was originally formulated by Lord Rayleigh nearly two centuries ago, it was devised in the 1940s and eventually became a calibration standard in the 1960s; however, it can only accommodate a limited number of acoustic sensors of specific types and dimensions. International standards determine the device sensitivity either through coupler or through free-field reciprocity but rely on the continuous availability of specific acoustical artefacts. Here, we show an optical method based on gated photon correlation spectroscopy that can measure sound pressures directly and absolutely in fully anechoic conditions, remotely, and without disturbing the propagating sound field. It neither relies on the availability or performance of any measurement artefact nor makes any assumptions of the device geometry and sound field characteristics. Most importantly, the required units of sound pressure and microphone sensitivity may now be experimentally realised, thus providing direct traceability to SI base units.

  15. Multispectral measurement of contrast in tissue-mimicking phantoms in near-infrared spectral range of 650 to 1600 nm

    Science.gov (United States)

    Salo, Daniel; Zhang, Hairong; Kim, David M.; Berezin, Mikhail Y.

    2014-01-01

    Abstract. In order to identify the optimal imaging conditions for the highest spatial contrast in biological tissue, we explored the properties of a tissue-mimicking phantom as a function of the wavelengths in a broad range of near-infrared spectra (650 to 1600 nm). Our customized multispectral hardware, which featured a scanning transmission microscope and imaging spectrographs equipped with silicon and InGaAs charge-coupled diode array detectors, allowed for direct comparison of the Michelson contrast obtained from a phantom composed of a honeycomb grid, Intralipid, and India ink. The measured contrast depended on the size of the grid, luminance, and the wavelength of measurements. We demonstrated that at low thickness of the phantom, a reasonable contrast of the objects can be achieved at any wavelength between 700 and 1400 nm and between 1500 and 1600 nm. At larger thicknesses, such contrast can be achieved mostly between 1200 and 1350 nm. These results suggest that distinguishing biological features in deep tissue and developing contrast agents for in vivo may benefit from imaging in this spectral range. PMID:25104414

  16. Measurements of complex permittivity of microwave substrates in the 20 to 300 K temperature range from 26.5 to 40.0 GHz

    Science.gov (United States)

    Miranda, Felix A.; Gordon, William L.; Heinen, Vernon O.; Ebihara, Ben T.; Bhasin, Kul B.

    1990-01-01

    A knowledge of the dielectric properties of microwve substrates at low temperatures is useful in the design of superconducting microwave circuits. Results are reported for a study of the complex permittivity of sapphire (Al2O3), magnesium oxide (MgO), silicon oxide (SiO2), lanthanum aluminate (LaAlO3), and zirconium oxide (ZrO2), in the 20 to 300 Kelvin temperature range, at frequencies from 26.5 to 40.0 GHz. The values of the real and imaginary parts of the complex permittivity were obtained from the scattering parameters, which were measured using an HP-8510 automatic network analyzer. For these measurements, the samples were mounted on the cold head of a helium gas closed cycle refrigerator, in a specially designated vacuum chamber. An arrangement of wave guides, with mica windows, was used to connect the cooling system to the network analyzer. A decrease in the value of the real part of the complex permittivity of these substrates, with decreasing temperature, was observed. For MgO and Al2O3, the decrease from room temperature to 20 K was of 7 and 15 percent, respectively. For LaAlO3, it decreased by 14 percent, for ZrO2 by 15 percent, and for SiO2 by 2 percent, in the above mentioned temperature range.

  17. Determination of vertebral range of motion using inertial measurement units in 27 Franches-Montagnes stallions and comparison between conditions and with a mixed population.

    Science.gov (United States)

    Heim, C; Pfau, T; Gerber, V; Schweizer, C; Doherr, M; Schüpbach-Regula, G; Witte, S

    2016-07-01

    The diagnosis of equine back disorders is challenging. Objectively determining movement of the vertebral column may therefore be of value in a clinical setting. To establish whether surface-mounted inertial measurement units (IMUs) can be used to establish normal values for range of motion (ROM) of the vertebral column in a uniform population of horses trotting under different conditions. Vertebral ROM was established in Franches-Montagnes stallions and a general population of horses and the variability in measurements compared between the two groups. Repeatability and the influence of specific exercise condition (on ROM) were assessed. Finally, attempts were made to explain the findings of the study through the evaluation of factors that might influence ROM. Dorsoventral (DV) and mediolateral (ML) vertebral ROM was measured at a trot under different exercise conditions in 27 Franches-Montagnes stallions and six general population horses using IMUs distributed over the vertebral column. Variability in the ROM measurements was significantly higher for general population horses than for Franches-Montagnes stallions (both DV and ML ROM). Repeatability was strong to very strong for DV measurements and moderate for ML measurements. Trotting under saddle significantly reduced the ROM, with sitting trot resulting in a significantly lower ROM than rising trot. Age is unlikely to explain the low variability in vertebral ROM recorded in the Franches-Montagnes horses, while this may be associated with conformational factors. It was possible to establish a normal vertebral ROM for a group of Franches-Montagnes stallions. While within-breed variation was low in this population, further studies are necessary to determine variation in vertebral ROM for other breeds and to assess their utility for diagnosis of equine back disorders. © 2015 EVJ Ltd.

  18. Statistical analysis of long- and short-range forces involved in bacterial adhesion to substratum surfaces as measured using atomic force microscopy.

    Science.gov (United States)

    Chen, Yun; Busscher, Henk J; van der Mei, Henny C; Norde, Willem

    2011-08-01

    Surface thermodynamic analyses of microbial adhesion using measured contact angles on solid substrata and microbial cell surfaces are widely employed to determine the nature of the adhesion forces, i.e., the interplay between Lifshitz-van der Waals and acid-base forces. While surface thermodynamic analyses are often viewed critically, atomic force microscopy (AFM) can also provide information on the nature of the adhesion forces by means of Poisson analysis of the measured forces. This review first presents a description of Poisson analysis and its underlying assumptions. The data available from the literature for different combinations of bacterial strains and substrata are then summarized, leading to the conclusion that bacterial adhesion to surfaces is generally dominated by short-range, attractive acid-base interactions, in combination with long-range, weaker Lifshitz-van der Waals forces. This is in line with the findings of surface thermodynamic analyses of bacterial adhesion. Comparison with single-molecule ligand-receptor forces from the literature suggests that the short-range-force contribution from Poisson analysis involves a discrete adhesive bacterial cell surface site rather than a single molecular force. The adhesion force arising from these cell surface sites and the number of sites available may differ from strain to strain. Force spectroscopy, however, involves the tedious task of identifying the minor peaks in the AFM retraction force-distance curve. This step can be avoided by carrying out Poisson analysis on the work of adhesion, which can also be derived from retraction force-distance curves. This newly proposed way of performing Poisson analysis confirms that multiple molecular bonds, rather than a single molecular bond, contribute to a discrete adhesive bacterial cell surface site.

  19. A Opinião dos Turistas de Negócios sobre a Imagem da Cidade de São Paulo

    Directory of Open Access Journals (Sweden)

    Luis Noriega Vera

    2010-07-01

    Full Text Available Resumo O artigo apresenta a análise descritiva dos principais resultados obtidos em pesquisa de campo realizada entre a segunda quinzena de junho e primeira de julho do ano de 2006 nos dois aeroportos da cidade de São Paulo. A pesquisa teve como público alvo os turistas de negócios que visitam a cidade. A amostra foi escolhida intencionalmente e o critério de estratificação foi o local de residência permanente dos turistas. O principal objetivo da pesquisa foi aprimorar o entendimento sobre a avaliação da imagem de um destino turístico. Foi proposto um modelo conceitual a partir do referencial teórico sobre comportamento do consumidor existente nas áreas de turismo e marketing. Os resultados apontam que o perfil dos turistas é consistente com estudos anteriores e a imagem da cidade consolidada como destino de negócios. Em adição é destacada a qualidade dos serviços consumidos, a satisfação e a intenção do turista de retornar e indicar o destino a parentes e amigos. Palavras-chave: destino turístico; turista de negócios; avaliação de imagem; qualidade; lealdade. Abstract This article presents the descriptive analysis of the main results of a survey held from June 15th through July 15th 2006 in the two São Paulo City airports. The survey targeted business tourists visiting the city. It was used an intentional sample and the stratification parameter was tourists’ place of permanent residence. The main objective was to enhance the knowledge on tourism destination image evaluation. A conceptual model was proposed based on tourism and marketing literature consumer behavior theoretical background. The results obtained pointed out that tourist profile are consistent with prior studies and the consolidated city image as a business destination. It is also highlighted its service quality, satisfaction and tourist’s intention to return or indicate the destination to relatives and friends. Keywords: tourism

  20. Analysis of aircraft and satellite measurements from the Intercontinental Chemical Transport Experiment (INTEX-B to quantify long-range transport of East Asian sulfur to Canada

    Directory of Open Access Journals (Sweden)

    A. van Donkelaar

    2008-06-01

    Full Text Available We interpret a suite of satellite, aircraft, and ground-based measurements over the North Pacific Ocean and western North America during April–May 2006 as part of the Intercontinental Chemical Transport Experiment Phase B (INTEX-B campaign to understand the implications of long-range transport of East Asian emissions to North America. The Canadian component of INTEX-B included 33 vertical profiles from a Cessna 207 aircraft equipped with an aerosol mass spectrometer. Long-range transport of organic aerosols was insignificant, contrary to expectations. Measured sulfate plumes in the free troposphere over British Columbia exceeded 2 μg/m3. We update the global anthropogenic emission inventory in a chemical transport model (GEOS-Chem and use it to interpret the observations. Aerosol Optical Depth (AOD retrieved from two satellite instruments (MISR and MODIS for 2000–2006 are analyzed with GEOS-Chem to estimate an annual growth in Chinese sulfur emissions of 6.2% and 9.6%, respectively. Analysis of aircraft sulfate measurements from the NASA DC-8 over the central Pacific, the NSF C-130 over the east Pacific and the Cessna over British Columbia indicates most Asian sulfate over the ocean is in the lower free troposphere (800–600 hPa, with a decrease in pressure toward land due to orographic effects. We calculate that 56% of the measured sulfate between 500–900 hPa over British Columbia is due to East Asian sources. We find evidence of a 72–85% increase in the relative contribution of East Asian sulfate to the total burden in spring off the northwest coast of the United States since 1985. Campaign-average simulations indicate anthropogenic East Asian sulfur emissions increase mean springtime sulfate in Western Canada at the surface by 0.31 μg/m3 (~30% and account for 50% of the overall regional sulfate burden between 1 and 5 km. Mean measured daily surface sulfate concentrations taken in the Vancouver area increase by

  1. Measurement of high-dynamic range x-ray Thomson scattering spectra for the characterization of nano-plasmas at LCLS

    Energy Technology Data Exchange (ETDEWEB)

    MacDonald, M. J., E-mail: macdonm@umich.edu [University of Michigan, Ann Arbor, Michigan 48109 (United States); SLAC National Accelerator Laboratory, Menlo Park, California 94025 (United States); Gorkhover, T. [SLAC National Accelerator Laboratory, Menlo Park, California 94025 (United States); Technische Universität, 10623 Berlin (Germany); Bachmann, B.; Hau-Riege, S. P.; Pardini, T.; Döppner, T. [Lawrence Livermore National Laboratory, Livermore, California 94551 (United States); Bucher, M. [SLAC National Accelerator Laboratory, Menlo Park, California 94025 (United States); Argonne National Lab, Lemont, Illinois 60439 (United States); Carron, S. [California Lutheran University, Thousand Oaks, California 91360 (United States); Coffee, R. N.; Fletcher, L. B.; Gamboa, E. J.; Glenzer, S. H.; Göde, S.; Krzywinski, J.; O’Grady, C. P.; Osipov, T.; Swiggers, M. [SLAC National Accelerator Laboratory, Menlo Park, California 94025 (United States); Drake, R. P. [University of Michigan, Ann Arbor, Michigan 48109 (United States); Ferguson, K. R. [SLAC National Accelerator Laboratory, Menlo Park, California 94025 (United States); Stanford University, Stanford, California 94305 (United States); Kraus, D. [University of California, Berkeley, California 94720 (United States); and others

    2016-11-15

    Atomic clusters can serve as ideal model systems for exploring ultrafast (∼100 fs) laser-driven ionization dynamics of dense matter on the nanometer scale. Resonant absorption of optical laser pulses enables heating to temperatures on the order of 1 keV at near solid density conditions. To date, direct probing of transient states of such nano-plasmas was limited to coherent x-ray imaging. Here we present the first measurement of spectrally resolved incoherent x-ray scattering from clusters, enabling measurements of transient temperature, densities, and ionization. Single shot x-ray Thomson scattering signals were recorded at 120 Hz using a crystal spectrometer in combination with a single-photon counting and energy-dispersive pnCCD. A precise pump laser collimation scheme enabled recording near background-free scattering spectra from Ar clusters with an unprecedented dynamic range of more than 3 orders of magnitude. Such measurements are important for understanding collective effects in laser-matter interactions on femtosecond time scales, opening new routes for the development of schemes for their ultrafast control.

  2. Normal ranges and test-retest reproducibility of flow and velocity parameters in intracranial arteries measured with phase-contrast magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Correia de Verdier, Maria; Wikstroem, Johan [Uppsala University Hospital, Department of Radiology, Uppsala University, Uppsala (Sweden)

    2016-05-15

    The purpose of the present study was to investigate normal ranges and test-retest reproducibility of phase-contrast MRI (PC-MRI)-measured flow and velocity parameters in intracranial arteries. Highest flow (HF), lowest flow (LF), peak systolic velocity (PSV), and end diastolic velocity (EDV) were measured at two dates in the anterior (ACA), middle (MCA), and posterior (PCA) cerebral arteries of 30 healthy volunteers using two-dimensional PC-MRI at 3 T. Least detectable difference (LDD) was calculated. In the left ACA, HF was (mean (range, LDD)) 126 ml/min (36-312, 59 %), LF 61 ml/min (0-156, 101 %), PSV 64 cm/s (32-141, 67 %), and EDV 35 cm/s (18-55, 42 %); in the right ACA, HF was 154 ml/min (42-246, 49 %), LF 77 ml/min (0-156, 131 %), PSV 75 cm/s (26-161, 82 %), and EDV 39 cm/s (7-59, 67 %). In the left MCA, HF was 235 ml/min (126-372, 35 %), LF 116 ml/min (42-186, 48 %), PSV 90 cm/s (55-183, 39 %), and EDV 46 cm/s (20-66, 28 %); in the right MCA, HF was 238 ml/min (162-342, 44 %), LF 120 ml/min (72-216, 48 %), PSV 88 cm/s (55-141, 35 %), and EDV 45 cm/s (26-67, 23 %). In the left PCA, HF was 108 ml/min (42-168, 54 %), LF 53 ml/min (18-108, 64 %), PSV 50 cm/s (24-77, 63 %), and EDV 28 cm/s (14-40, 45 %); in the right PCA, HF was 98 ml/min (30-162, 49 %), LF 49 ml/min (12-84, 55 %), PSV 47 cm/s (27-88, 59 %), and EDV 27 cm/s (16-41, 45 %). PC-MRI-measured flow and velocity parameters in the main intracranial arteries have large normal ranges. Reproducibility is highest in MCA. (orig.)

  3. Agreement of high definition oscillometry with direct arterial blood pressure measurement at different blood pressure ranges in horses under general anaesthesia.

    Science.gov (United States)

    Tünsmeyer, Julia; Hopster, Klaus; Feige, Karsten; Kästner, Sabine Br

    2015-05-01

    To determine the agreement of high definition oscillometry (HDO) with direct arterial blood pressure measurements in normotensive, hypotensive and hypertensive horses during general anaesthesia. Experimental study. Seven healthy warmblood horses, aged 3-11 years, weighing 470-565 kg. Measurements from a HDO device with the cuff placed around the base of the tail were compared with pressures measured invasively from the facial artery. High blood pressures were induced by intravenous (IV) administration of dobutamine (5 μg kg(-1) minute(-1)) over ten minutes followed by norepinephrine (0.1 mg kg(-1) IV) and low pressures by increasing the inspired fraction of isoflurane and administration of nitroglycerine (0.05 mg kg(-1) IV). For analysis three pressure levels were determined: high (MAP>110 mmHg), normal (60 mmHginvasive and invasive measurements. A total of 245 paired measurements of systolic (SAP), mean (MAP) and diastolic (DAP) pressures were obtained. The HDO device underestimated blood pressure at hypertensive and normotensive levels and overestimated blood pressure at hypotensive levels. Best agreement was obtained for SAP and MAP within normotensive limits. At normotension, bias ± standard deviation for SAP, MAP and DAP were 0.1 ± 19.4 mmHg, 0.5 ± 14.0, 4.7 ± 15.6, respectively. At high pressure levels bias and SD were 26.1 ± 37.3 (SAP), 4.2 ± 19.4 (MAP), 1.5 ± 16.8 (DAP) and at low pressures -20.0 ± 20.9 (SAP), -11.4 ± 19.6 (MAP), -4.7 ± 20.1 (DAP), with HDO measurements at a MAP invasive arterial blood pressures was obtained with HDO at normotensive levels in horses. At high and low pressure ranges HDO was unreliable. Therefore, if haemodynamic instability is expected, invasive measurement remains preferable. © 2014 Association of Veterinary Anaesthetists and the American College of Veterinary Anesthesia and Analgesia.

  4. Plano de negócios para a instalação de uma comercial de implementos agrícolas

    OpenAIRE

    Tengaten, Juliane

    2015-01-01

    Em um ambiente competitivo, ao implementar um empreendimento, é de suma importância a análise de um plano de negócio como um todo, nesse foco, o objetivo principal do estudo é analisar se é viável ou não a instalação da organização, ou seja, a constituição de uma empresa de revenda de máquinas e implementos agrícolas, empreendimento ligado diretamente ao agronegócio. A metodologia utilizada constitui-se em pesquisa aplicada, descritiva, bibliográfica, buscando em livros, internet, artigos e p...

  5. Transplantation of Allogeneic PW1pos/Pax7neg Interstitial Cells Enhance Endogenous Repair of Injured Porcine Skeletal Muscle

    Directory of Open Access Journals (Sweden)

    Fiona C. Lewis, BSc, PhD

    2017-12-01

    Full Text Available Skeletal muscle-derived PW1pos/Pax7neg interstitial cells (PICs express and secrete a multitude of proregenerative growth factors and cytokines. Utilizing a porcine preclinical skeletal muscle injury model, delivery of allogeneic porcine PICs (pPICs significantly improved and accelerated myofiber regeneration and neocapillarization, compared with saline vehicle control-treated muscles. Allogeneic pPICs did not contribute to new myofibers or capillaries and were eliminated by the host immune system. In conclusion, allogeneic pPIC transplantation stimulated the endogenous stem cell pool to bring about enhanced autologous skeletal muscle repair and regeneration. This allogeneic cell approach is considered a cost-effective, easy to apply, and readily available regenerative therapeutic strategy.

  6. Photo-dynamics of the lyophilized photo-activated adenylate cyclase NgPAC2 from the amoeboflagellate Naegleria gruberi NEG-M strain

    Science.gov (United States)

    Penzkofer, A.; Tanwar, M.; Veetil, S. K.; Kateriya, S.; Stierl, M.; Hegemann, P.

    2013-09-01

    The absorption and emission spectroscopic behavior of lyophilized photo-activated adenylate cyclase NgPAC2 from the amoeboflagellate Naegleria gruberi NEG-M strain consisting of a BLUF domain (BLUF = Blue Light sensor Using Flavin) and a cyclase homology domain was studied in the dark, during blue-light exposure and after blue-light exposure at a temperature of 4 °C. The BLUF domain photo-cycle dynamics observed for snap-frozen NgPAC2 was lost by lyophilization (no signaling state formation with flavin absorption red-shift). Instead, blue-light photo-excitation of lyophilized NgPAC2 caused sterically restricted Tyr-Tyr cross-linking (o,o‧-ditysosine formation) and partial flavin cofactor reduction.

  7. Congruências entre posicionamentos estratégicos e redes de negócios: estudo de caso de uma subsidiária brasileira

    Directory of Open Access Journals (Sweden)

    Márcio Roberto Moran

    2012-03-01

    Full Text Available Na pesquisa exploratória aqui relatada, realizada em 2009 e guiada por uma extensa revisão bibliográfica e pelo emprego do método de estudo de caso, busca-se identificar congruências entre o posicionamento estratégico adotado pela subsidiária brasileira de uma corporação multinacional e o tipo de rede de negócios por ela integrada. Apoiando-se em dois modelos específicos da literatura acadêmica sobre os temas mencionados (posicionamento estratégico e redes, as conclusões dessa investigação sugerem que as Redes Verticais de Demanda e Fornecimento (MOLLER e RAJALA, 2007 são adequadas para operacionalizar o posicionamento definido como Melhor Produto no Modelo Delta (HAX e WILDE II, 1999; 2001.

  8. Elaboração do mapa de recursos: processo de apoio ao planejamento de um novo negócio de internet

    Directory of Open Access Journals (Sweden)

    Josué Vitor de Medeiros Júnior

    2015-10-01

    Full Text Available O artigo tem como objetivo apresentar a aplicação de um método de elaboração do Mapa de Recursos para apoiar o planejamento de um novo negócio baseado na internet a partir da percepção do seu empreendedor. O mapa de recursos resultante é uma representação visual das inter-relações entre os recursos estratégicos, assim caracterizados em função dos pressupostos teóricos da Visão Baseada em Recursos (VBR, bem como da Dinâmica de Sistemas, que caracteriza tais representações por enlaces de feedback, fluxos e acumulações, responsáveis por comportamentos de aspectos sistêmicos como o desempenho organizacional. Em relação a metodologia, a pesquisa se caracteriza como exploratória descritiva, subtipo estudo de caso e para a coleta de dados foram utilizados questionários e entrevistas com o empreendedor responsável pelo negócio. O método da elaboração do mapa ocorreu em algumas etapas como levantamento e seleção dos recursos estratégicos da empresa, definição dos fluxos de acúmulo dos recursos e os relacionamentos entre eles, identificação das políticas de desenvolvimento dos recursos, incorporação de variáveis financeiras e identificação das capacidades responsáveis pelo desenvolvimento do negócio. Como resultados da pesquisa, obteve-se a identificação e classificação dos recursos estratégicos da organização e como esses recursos se inter-relacionam e impactam no seu desempenho. A originalidade do trabalho se justifica pela construção do mapa de recursos em uma empresa nascente, auxiliando o empreendedor a identificar e explorar os recursos estratégicos iniciais e como a tomada de decisão por parte do empreendedor pode impactar no desempenho da empresa. Como contribuição, o processo de elaboração do mapa, através de uma representação visual não linear dos recursos estratégicos, a partir do modelo mental do empreendedor, mostrou-se como um processo de aprendizado e reflexão sobre

  9. Elaboração do mapa de recursos: processo de apoio ao planejamento de um novo negócio de internet

    OpenAIRE

    Josué Vitor Medeiros Júnior; Miguel Eduardo Moreno Añez; Manoel Veras de Sousa Neto; Marcelo Hugo de Medeiros Bezerra

    2015-01-01

    RESUMOO artigo tem como objetivo apresentar a aplicação de um método de elaboração do mapa de recursos para apoiar o planejamento de um novo negócio baseado na internet a partir da percepção do seu empreendedor. O mapa de recursos resultante é uma representação visual das inter-relações entre os recursos estratégicos, assim caracterizados em função dos pressupostos teóricos da visão baseada em recursos (resource-based view – VBR), bem como da dinâmica de sistemas, que caracteriza tais r...

  10. Measured sections and discussion of the main turbidite member, Middle Pennsylvanian Minturn Formation, northern Sangre de Cristo Range, Custer and Saguache counties, Colorado

    Science.gov (United States)

    Soulliere, S.J.; DeAngelis, B.L.; Lindsey, D.A.

    1984-01-01

    Turbidites are sediments deposited by turbid density currents. The turbidites described here are interpreted as prodelta deposits that formed in front of fan deltas and alluvial fans during the uplift of the ancestral Rocky Mountains in Pennsylvanian time. Laterally extensive, lenticular sand bodies deposited by turbidity flows crop out in the Middle Pennsylvanian Minturn Formation in the northern Sangre de Crísto Range, Custer and Saguache Counties, Colo. (figs. 1, 2). One of the turbidite-bearing intervals, informally designated the "main turbidite member," lies 90.6 m above the base of the Minturn; it reaches 150 m in thickness and extends more than 13 km along strike. The internal stratigraphy and sedimentary structures of the main turbidite member are described from the measured sections presented here.

  11. Discovery and cross-section measurement of neutron-rich isotopes in the element range from neodymium to platinum with the FRS

    Energy Technology Data Exchange (ETDEWEB)

    Kurcewicz, J., E-mail: j.kurcewicz@gsi.de [GSI Helmholtzzentrum fuer Schwerionenforschung, 64291 Darmstadt (Germany); Farinon, F.; Geissel, H. [GSI Helmholtzzentrum fuer Schwerionenforschung, 64291 Darmstadt (Germany); Justus-Liebig-Universitaet Giessen, 35392 Giessen (Germany); Pietri, S.; Nociforo, C. [GSI Helmholtzzentrum fuer Schwerionenforschung, 64291 Darmstadt (Germany); Prochazka, A. [GSI Helmholtzzentrum fuer Schwerionenforschung, 64291 Darmstadt (Germany); Justus-Liebig-Universitaet Giessen, 35392 Giessen (Germany); Weick, H.; Winfield, J.S. [GSI Helmholtzzentrum fuer Schwerionenforschung, 64291 Darmstadt (Germany); Estrade, A. [GSI Helmholtzzentrum fuer Schwerionenforschung, 64291 Darmstadt (Germany); Astronomy and Physics Department, Saint Mary' s University, Halifax, Nova Scotia B3H 3C3 (Canada); Allegro, P.R.P. [Institute of Physics, Universidade de Sao Paulo, CEP 05508-090 Cidade Universitaria, Sao Paulo (Brazil); Bail, A.; Belier, G. [CEA DAM DiF, 91290 Arpajon Cedex (France); Benlliure, J. [Universidad de Santiago de Compostela, E-15706 Santiago de Compostella (Spain); Benzoni, G. [INFN sezione di Milano, I-20133 Milano (Italy); Bunce, M.; Bowry, M. [Department of Physics, University of Surrey, Guildford, Surrey, GU2 7XH (United Kingdom); Caballero-Folch, R. [Universitat Politecnica de Catalunya, 08034 Barcelona (Spain); and others

    2012-10-31

    Using the high-resolution performance of the fragment separator FRS at GSI we have discovered 60 new neutron-rich isotopes in the atomic number range of 60 Less-Than-Or-Slanted-Equal-To Z Less-Than-Or-Slanted-Equal-To 78. The new isotopes were unambiguously identified in reactions with a {sup 238}U beam impinging on a Be target at 1 GeV/nucleon. The production cross-section for the new isotopes have been measured down to the pico-barn level and compared with predictions of different model calculations. For elements above hafnium fragmentation is the dominant reaction mechanism which creates the new isotopes, whereas fission plays a dominant role for the production of the new isotopes up to thulium.

  12. Discovery and cross-section measurement of neutron-rich isotopes in the element range from neodymium to platinum with the FRS

    Science.gov (United States)

    Kurcewicz, J.; Farinon, F.; Geissel, H.; Pietri, S.; Nociforo, C.; Prochazka, A.; Weick, H.; Winfield, J. S.; Estradé, A.; Allegro, P. R. P.; Bail, A.; Bélier, G.; Benlliure, J.; Benzoni, G.; Bunce, M.; Bowry, M.; Caballero-Folch, R.; Dillmann, I.; Evdokimov, A.; Gerl, J.; Gottardo, A.; Gregor, E.; Janik, R.; Kelić-Heil, A.; Knöbel, R.; Kubo, T.; Litvinov, Yu. A.; Merchan, E.; Mukha, I.; Naqvi, F.; Pfützner, M.; Pomorski, M.; Podolyák, Zs.; Regan, P. H.; Riese, B.; Ricciardi, M. V.; Scheidenberger, C.; Sitar, B.; Spiller, P.; Stadlmann, J.; Strmen, P.; Sun, B.; Szarka, I.; Taïeb, J.; Terashima, S.; Valiente-Dobón, J. J.; Winkler, M.; Woods, Ph.

    2012-10-01

    Using the high-resolution performance of the fragment separator FRS at GSI we have discovered 60 new neutron-rich isotopes in the atomic number range of 60 ⩽ Z ⩽ 78. The new isotopes were unambiguously identified in reactions with a 238U beam impinging on a Be target at 1 GeV/nucleon. The production cross-section for the new isotopes have been measured down to the pico-barn level and compared with predictions of different model calculations. For elements above hafnium fragmentation is the dominant reaction mechanism which creates the new isotopes, whereas fission plays a dominant role for the production of the new isotopes up to thulium.

  13. Measurement of activation cross-section of long-lived products in deuteron induced nuclear reactions on palladium in the 30-50MeV energy range.

    Science.gov (United States)

    Ditrói, F; Tárkányi, F; Takács, S; Hermanne, A; Ignatyuk, A V

    2017-10-01

    Excitation functions were measured in the 31-49.2MeV energy range for the natPd(d,xn)111,110m,106m,105,104g,103Ag, natPd(d,x) 111m,109,101,100Pd, natPd(d,x), 105,102m,102g,101m,101g,100,99m,99gRh and natPd(d,x)103,97Ru nuclear reactions by using the stacked foil irradiation technique. The experimental results are compared with our previous results and with the theoretical predictions calculated with the ALICE-D, EMPIRE-D and TALYS (TENDL libraries) codes. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Measurements of the Atmospheric Electric Field through a Triangular Array and the Long-range Saharan Dust Electrification in Southern Portugal

    CERN Document Server

    Silva, H G; Pereira, S; Barbosa, S M; Nicoll, K; Pereira, M Collares; Harrison, R G

    2016-01-01

    Atmospheric electric field (AEF) measurements were carried out in three different sites forming a triangular array in Southern Portugal. The campaign was performed during the summer characterized by Saharan dust outbreaks; the 16th-17th July 2014 desert dust event is considered here. Evidence of long-range dust electrification is attributed to the air-Earth electrical current creating a positive space-charge inside of the dust layer. An increase of ~23 V/m is observed in AEF on the day of the dust event corresponding to space-charges of ~20-2 pCm-3 (charge layer thicknesses ~10-100 m). A reduction of AEF is observed after the dust event.

  15. Reliability and validity of CODA motion analysis system for measuring cervical range of motion in patients with cervical spondylosis and anterior cervical fusion.

    Science.gov (United States)

    Gao, Zhongyang; Song, Hui; Ren, Fenggang; Li, Yuhuan; Wang, Dong; He, Xijing

    2017-12-01

    The aim of the present study was to evaluate the reliability of the Cartesian Optoelectronic Dynamic Anthropometer (CODA) motion system in measuring the cervical range of motion (ROM) and verify the construct validity of the CODA motion system. A total of 26 patients with cervical spondylosis and 22 patients with anterior cervical fusion were enrolled and the CODA motion analysis system was used to measure the three-dimensional cervical ROM. Intra- and inter-rater reliability was assessed by interclass correlation coefficients (ICCs), standard error of measurement (SEm), Limits of Agreements (LOA) and minimal detectable change (MDC). Independent samples t-tests were performed to examine the differences of cervical ROM between cervical spondylosis and anterior cervical fusion patients. The results revealed that in the cervical spondylosis group, the reliability was almost perfect (intra-rater reliability: ICC, 0.87-0.95; LOA, -12.86-13.70; SEm, 2.97-4.58; inter-rater reliability: ICC, 0.84-0.95; LOA, -13.09-13.48; SEm, 3.13-4.32). In the anterior cervical fusion group, the reliability was high (intra-rater reliability: ICC, 0.88-0.97; LOA, -10.65-11.08; SEm, 2.10-3.77; inter-rater reliability: ICC, 0.86-0.96; LOA, -10.91-13.66; SEm, 2.20-4.45). The cervical ROM in the cervical spondylosis group was significantly higher than that in the anterior cervical fusion group in all directions except for left rotation. In conclusion, the CODA motion analysis system is highly reliable in measuring cervical ROM and the construct validity was verified, as the system was sufficiently sensitive to distinguish between the cervical spondylosis and anterior cervical fusion groups based on their ROM.

  16. Long-term high frequency measurements of ethane, benzene and methyl chloride at Ragged Point, Barbados: Identification of long-range transport events

    Directory of Open Access Journals (Sweden)

    A.T. Archibald

    2015-09-01

    Full Text Available AbstractHere we present high frequency long-term observations of ethane, benzene and methyl chloride from the AGAGE Ragged Point, Barbados, monitoring station made using a custom built GC-MS system. Our analysis focuses on the first three years of data (2005–2007 and on the interpretation of periodic episodes of high concentrations of these compounds. We focus specifically on an exemplar episode during September 2007 to assess if these measurements are impacted by long-range transport of biomass burning and biogenic emissions. We use the Lagrangian Particle Dispersion model, NAME, run forwards and backwards in time to identify transport of air masses from the North East of Brazil during these events. To assess whether biomass burning was the cause we used hot spots detected using the MODIS instrument to act as point sources for simulating the release of biomass burning plumes. Excellent agreement for the arrival time of the simulated biomass burning plumes and the observations of enhancements in the trace gases indicates that biomass burning strongly influenced these measurements. These modelling data were then used to determine the emissions required to match the observations and compared with bottom up estimates based on burnt area and literature emission factors. Good agreement was found between the two techniques highlight the important role of biomass burning. The modelling constrained by in situ observations suggests that the emission factors were representative of their known upper limits, with the in situ data suggesting slightly greater emissions of ethane than the literature emission factors account for. Further analysis was performed concluding only a small role for biogenic emissions of methyl chloride from South America impacting measurements at Ragged Point. These results highlight the importance of long-term high frequency measurements of NMHC and ODS and highlight how these data can be used to determine sources of emissions

  17. Reproducible measurement of vancomycin MICs within the susceptible range in Staphylococcus aureus by a broth microdilution method with a "quasi-continuum" gradient of antibiotic concentrations.

    Science.gov (United States)

    Falcón, R; Mateo, E M; Talaya, A; Giménez, E; Vinuesa, V; Clari, M Á; Navarro, D

    2017-12-01

    The availability of reproducible broth microdilution (BMD) methods including inter log 2 antibiotic dilutions for measuring Staphylococcus aureus (SA) vancomycin minimum inhibitory concentrations (MICs) within the susceptible range is needed to elucidate the impact of vancomycin MICs on clinical outcomes of invasive SA infections. Here, we report on the development of a very precise BMD method that incorporates the following incremental antibiotic concentrations: 0.50, 0.62, 0.75, 0.87, 1.0, 1.25, 1.40, 1.50, 1.60, 1.75, and 2.0 μg/mL. The intra- and inter-assay coefficients of variation of this method were around 20%. The mean of the differences in MIC values for all isolates obtained across two independent runs performed at one center was 0.04 μg/mL [95% confidence interval (CI), 0.011-0.07 μg/mL] and that for ten isolates measured at two different centers was 0.04 μg/mL (95% CI, 0-13 μg/mL). Vancomycin MIC values differed by less than 0.1 μg/mL between runs for most isolates. Storage of isolates at -20 °C for up to 3 months had no impact on the vancomycin MIC values. The mean vancomycin MIC values obtained by the Etest using a standard inoculum (0.5 McFarland) were significantly higher (p ≤ 0.001) than those measured by BMD and the MIC values measured by the two methods correlated poorly (Rho, 0.319; p = 0.148). Nevertheless, the mean MIC values measured by the Etest using lower inocula (10 7 or 10 6  CFU/mL) and those measured by BMD were comparable and correlated significantly (p = 0.004 for 10 7  CFU/mL and p = 0.029 for 10 6  CFU/mL).

  18. Measurements of the reaction e/+/e/-/ yielding gamma-gamma at center-of-mass energies in the range 6.2-7.4 GeV

    Science.gov (United States)

    Hilger, E.; Beron, B. L.; Carrington, R. L.; Ford, R. L.; Hill, W. T.; Hofstadter, R.; Hughes, E. B.; Liberman, A. D.; Martin, T. W.; Oneill, L. H.

    1977-01-01

    The cross section for the pair-annihilation reaction e(+)e(-) yields gamma-gamma were measured at center-of-mass energies in the range 6.2-7.4 GeV and at production angles close to 90 deg. The experimental apparatus consisted of two identical spectrometers which were set to view the luminous region at SPEAR-II from opposite directions at an azimuthal angle of 45 deg. In each spectrometer there was a NaI(TI) crystal 20 radiation lengths thick and 30 in. in diameter to measure the gamma-ray energies. Annihilation events were detected by an electronic trigger which required only the observation in coincidence of more than 0.2 GeV in each NaI(TI) crystal within + or - 15 nsec of the crossing beams. The observed rates of pair-annihilation events were found to be in agreement with those expected from quantum electrodynamics (QED) at all the center-of-mass energies used.

  19. Sample environment for neutron scattering measurements of internal stresses in engineering materials in the temperature range of 6 K to 300 K.

    Science.gov (United States)

    Kirichek, O; Timms, J D; Kelleher, J F; Down, R B E; Offer, C D; Kabra, S; Zhang, S Y

    2017-02-01

    Internal stresses in materials have a considerable effect on material properties including strength, fracture toughness, and fatigue resistance. The ENGIN-X beamline is an engineering science facility at ISIS optimized for the measurement of strain and stress using the atomic lattice planes as a strain gauge. Nowadays, the rapidly rising interest in the mechanical properties of engineering materials at low temperatures has been stimulated by the dynamic development of the cryogenic industry and the advanced applications of the superconductor technology. Here we present the design and discuss the test results of a new cryogenic sample environment system for neutron scattering measurements of internal stresses in engineering materials under a load of up to 100 kN and in the temperature range of 6 K to 300 K. Complete cooling of the system starting from the room temperature down to the base temperature takes around 90 min. Understanding of internal stresses in engineering materials at cryogenic temperatures is vital for the modelling and designing of cutting-edge superconducting magnets and other superconductor based applications.

  20. Measurement of the neutron fields produced by a 62 MeV proton beam on a PMMA phantom using extended range Bonner sphere spectrometers

    Science.gov (United States)

    Amgarou, K.; Bedogni, R.; Domingo, C.; Esposito, A.; Gentile, A.; Carinci, G.; Russo, S.

    2011-10-01

    The experimental characterization of the neutron fields produced as parasitic effect in medical accelerators is assuming an increased importance for either the patient protection or the facility design aspects. Medical accelerators are diverse in terms of particle type (electrons or hadrons) and energy, but the radiation fields around them have in common (provided that a given threshold energy is reached) the presence of neutrons with energy span over several orders of magnitude. Due to the large variability of neutron energy, field or dosimetry measurements in these workplaces are very complex, and in general, cannot be performed with ready-to-use commercial instruments. In spite of its poor energy resolution, the Bonner Sphere Spectrometer (BSS) is the only instrument able to simultaneously determine all spectral components in such workplaces. The energy range of this instrument is limited to EFisica Nucleare—Laboratori Nazionali di Frascati) were exposed to characterize the "forward" and "sideward" proton-induced neutron fields. The use of two ERBSS characterized by different set of spheres, central detectors, and independently established and calibrated, is important for guaranteeing the robustness of the measured spectra and estimating their overall uncertainties.

  1. Measurements of ion cyclotron range of frequencies mode converted wave intensity with phase contrast imaging in Alcator C-Mod and comparison with full-wave simulations

    Energy Technology Data Exchange (ETDEWEB)

    Tsujii, N.; Porkolab, M.; Bonoli, P. T.; Lin, Y.; Wright, J. C.; Wukitch, S. J. [MIT Plasma Science and Fusion Center, Cambridge, Massachusetts 02139 (United States); Jaeger, E. F. [XCEL Engineering, Inc., Oak Ridge, Tennessee 37830 (United States); Green, D. L. [Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831 (United States); Harvey, R. W. [CompX, Del Mar, California 92014 (United States)

    2012-08-15

    Radio frequency waves in the ion cyclotron range of frequencies (ICRF) are widely used to heat tokamak plasmas. In ICRF heating schemes involving multiple ion species, the launched fast waves convert to ion cyclotron waves or ion Bernstein waves at the two-ion hybrid resonances. Mode converted waves are of interest as actuators to optimise plasma performance through current drive and flow drive. In order to describe these processes accurately in a realistic tokamak geometry, numerical simulations are essential, and it is important that these codes be validated against experiment. In this study, the mode converted waves were measured using a phase contrast imaging technique in D-H and D-{sup 3}He plasmas. The measured mode converted wave intensity in the D-{sup 3}He mode conversion regime was found to be a factor of {approx}50 weaker than the full-wave predictions. The discrepancy was reduced in the hydrogen minority heating regime, where mode conversion is weaker.

  2. VOC Measurements in the Northern Colorado Front Range Metropolitan Area: Investigating the Impact of Oil and Natural Gas Emissions on O3 Production

    Science.gov (United States)

    Abeleira, A.; Farmer, D.; Fischer, E. V.; Pollack, I. B.; Zaragoza, J.

    2015-12-01

    Authors: Ilana Pollock1,2, Jake Zaragoza2, Emily V. Fischer2, Delphine K. Farmer11. Department of Chemistry, Colorado State University, Fort Collins, CO 2. Department of Atmospheric Science, Colorado State University, Fort Collins, CO During summer months, the Northern Front Range Metropolitan Area (NFRMA) of Colorado consistently violates the 75 ppbv 8-hour EPA National Ambient Air Quality Standard (NAAQS) for ambient ozone (O3), despite continued reduction in anthropogenic emissions. The region has been deemed an O3 non-attainment zone since 2008. Ground-level O3 is produced from photochemical catalytic cycles involving OH radicals, volatile organic compounds (VOCs), and NOx (NO + NO2). VOC emissions in the NFRMA are dominated by anthropogenic sources and influenced by biogenic and agricultural sources, while NOx emissions are mainly from automobile exhaust. A growing concern in the region is the role of oil and natural gas (ONG) on VOC concentrations and the potential for O3 production. Increases in local VOC emissions will likely cause subsequent increase in local O3 concentrations as PO3 increases in a region that is already affected by high O3episodes. As a part of the SONGNEX 2015 (Shale Oil and Natural Gas Nexus) campaign, we measured a broad suite of speciated VOCs during two 8-week deployments (March-May 2015, July-September 2015) at the Boulder Atmospheric Observatory in Erie, CO. VOC measurements were made with a custom-online multichannel gas chromatography system (50+ compounds hourly), along with measurements of O3, SO2, NOx, NOy, PAN, CO, CO2, and CH4. We use these data to investigate the role of different VOC sources, and ONG in particular, in contributing to VOC reactivity and thus instantaneous O3 production. Preliminary analysis of the Spring VOC data indicates that VOC reactivity is dominated by light alkanes typical of ONG emissions - specifically propane, consistent with previous winter-time studies. We will use the observed temperature

  3. Solubility Measurements and Predictions of Gypsum, Anhydrite, and Calcite Over Wide Ranges of Temperature, Pressure, and Ionic Strength with Mixed Electrolytes

    Science.gov (United States)

    Dai, Zhaoyi; Kan, Amy T.; Shi, Wei; Zhang, Nan; Zhang, Fangfu; Yan, Fei; Bhandari, Narayan; Zhang, Zhang; Liu, Ya; Ruan, Gedeng; Tomson, Mason B.

    2017-02-01

    Today's oil and gas production from deep reservoirs permits exploitation of more oil and gas reserves but increases risks due to conditions of high temperature and high pressure. Predicting mineral solubility under such extreme conditions is critical for mitigating scaling risks, a common and costly problem. Solubility predictions use solubility products and activity coefficients, commonly from Pitzer theory virial coefficients. However, inaccurate activity coefficients and solubility data have limited accurate mineral solubility predictions and applications of the Pitzer theory. This study measured gypsum solubility under its stable phase conditions up to 1400 bar; it also confirmed the anhydrite solubility reported in the literature. Using a novel method, the virial coefficients for Ca2+ and {{SO}}4^{2 - } (i.e., β_{{{{CaSO}}4 }}^{(0)} ,β_{{{{CaSO}}4 }}^{(2)} ,C_{{{{CaSO}}4 }}^{φ }) were calculated over wide ranges of temperature and pressure (0-250 °C and 1-1400 bar). The determination of this set of virial coefficients widely extends the applicable temperature and pressure ranges of the Pitzer theory in Ca2+ and SO 4 2- systems. These coefficients can be applied to improve the prediction of calcite solubility in the presence of high concentrations of Ca2+ and SO 4 2- ions. These new virial coefficients can also be used to predict the solubilities of gypsum and anhydrite accurately. Moreover, based on the derived β_{{{{CaSO}}4 }}^{(2)} values in this study, the association constants of {{CaSO}}4^{( 0 )} at 1 bar and 25 °C can be estimated by K_{{assoc}} = - 2β_{{{{CaSO}}4 }}^{(2)}. These values match very well with those reported in the literature based on other methods.

  4. Variable- and fixed-point blackbody sources developed at VNIIOFI for precision measurements in radiometry and thermometry within 100K-3500K temperature range

    Science.gov (United States)

    Sapritsky, V. I.; Khlevnoy, B. B.; Ogarev, S. A.; Privalsky, V. E.; Samoylov, M. L.; Sakharov, M. K.; Bourdakin, A. A.; Panfilov, A. S.

    2006-09-01

    The demands of modern radiation thermometry and radiometry are being satisfied by a large variety of high-precision unique BB sources (both fixed-point and variable temperature) designed for a wide range of temperature from 100 K to 3500 K. The paper contains a detailed review of low-, medium- and high-temperature precision blackbodies developed at VNIIOFI as the basis of the spectral radiance and irradiance calibration devices in the rank of National standards. The blackbodies include: 1) variable-temperature (100K..1000K) research-grade extended-area (up to 100 mm) models intended to perform radiometric calibrations by comparison with a primary standard source, as well as can be used as the sources for high-accuracy IR calibration of space-borne and other systems not requiring a vacuum environment; 2) low-temperature fixed-point blackbodies on the basis of phase transitions of pure metals such as In and Ga sources, and the metal-metal eutectics operating within the medium-temperature range (300K to 400K); these are used for pyrometric measurements, IR-radiometry, preflight and (future aspects) in-flight calibration of space borne IR instruments; 3) high-temperature wide aperture variable-temperature blackbodies (1800K to 3500K) such as BB3500MP, BB3500YY designed and fabricated, along with fixed-point cells working above the ITS-90 temperatures on the basis of phase transitions of metal-carbon eutectic alloys (Re-C, TiC-C, ZrC-C, HfC-C), which possess unique reproducibility of 0.1% or less.

  5. Determination of the Thermal Diffusivity of Electrically Non-Conductive Solids in the Temperature Range from 80 K to 300 K by Laser-Flash Measurement

    Science.gov (United States)

    Hemberger, F.; Göbel, A.; Ebert, H.-P.

    2010-12-01

    The adoption of the popular laser-flash method at temperatures far below 300 K is restricted by the weak signal-to-noise ratio and the limited spectral bandwidth of the commonly used mercury cadmium tellurite (MCT) infrared (IR) detector used as a non-contacting temperature probe. In this work, a different approach to measure the temperature rise in pulse heating experiments is described and evaluated. This method utilizes the change of the temperature-dependent electrical resistance of a thin strip of sputtered gold for the detection of a temperature rise as it was proposed by Kogure et al. The main advantage of this method at lower temperatures is the significantly higher signal-to-noise ratio compared to the commonly used IR detectors. A newly developed laser-flash apparatus using this detection method for the determination of the thermal diffusivity in the temperature range from 80 K to 300 K is presented. To test the accuracy of the new detection method, the thermal diffusivity of a borosilicate crown glass (BK7) specimen at 300 K was determined and compared to results derived with a MCT detector. Good agreement of the derived thermal diffusivity values within 3 % was found. The thermal diffusivity of BK7 and polycrystalline aluminum nitride (AlN) was measured at temperatures between 80 K and 300 K by a laser-flash method to test the functionality of the apparatus. Finally, the thermal conductivity was calculated using values for the specific heat capacity determined by temperature modulated differential scanning calorimetry (MDSC). Comparisons with literature data confirm the reliability of the experimental setup.

  6. Aircraft-borne aerosol chemical composition measurements in the lower to middle troposphere over southern West Africa: Biomass burning, urban outflow plumes, and long-range transport.

    Science.gov (United States)

    Batenburg, Anneke; Schulz, Christiane; Schneider, Johannes; Sauer, Daniel; Schlager, Hans; Borrmann, Stephan

    2017-04-01

    During the DACCIWA field campaign in June and July 2016, aircraft-borne in-situ aerosol chemical composition measurements were performed over southern West Africa (SWA). This presentation will focus on the submicron particle measurements done with a Compact Time-of-Flight Aerosol Mass Spectrometer (C-ToF-AMS) on board of the DLR Falcon aircraft during twelve research flights from Lomé, Togo, covering the altitude range from the boundary layer (BL) to the middle troposphere (12 km). A preliminary analysis of the results shows typical baseline total non-refractory aerosol mass loadings of 1.5 to 2.8 μg m-3 in the BL, and 0.4 to 1.1 μg m-3above. Up to half of the baseline aerosol mass in the BL appears to consist of sulphate, compared to only 10 to 35 % above the BL; organic matter dominates in the middle troposphere. During several flights, the DLR Falcon crossed a pronounced and seemingly widespread aerosol layer at 2—4.5 km altitude, partly in or slightly above the BL. The AMS data indicate that about half of the non-refractory aerosol mass in the middle of this layer consisted of organic matter. We consider it likely that these aerosol particles were produced by biomass burning in Central Africa. Emissions from cities and industrial areas were also intercepted, as well as enhancements in some species at higher altitudes. Trajectory analysis suggests that an increase of the organics to more than 2.5 μg m-3 observed at 8 km during one flight came from the Arabian Peninsula. Several ammonium peaks during the same flight at higher altitudes were traced back to the Asian Summer Monsoon Anticyclone (ASMA).

  7. Investigations of coal ignition in a short-range flame burner using optical measuring systems; Untersuchungen zur Kohlezuendung am Flachflammenbrenner unter Verwendung optischer Messtechnik

    Energy Technology Data Exchange (ETDEWEB)

    Hackert, G.; Kremer, H.; Wirtz, S. [Bochum Univ. (Germany). Lehrstuhl fuer Energieanlagentechnik

    1999-09-01

    The short-range flame burner and the KOALA reactor of DMT are experimental facilities for realistic simulation of coal conversion processes at high temperatures and pressures in atmospheric conditions. The TOSCA system enable measurements of temperatures, sizes, shapes and velocities of the fuel particles, which serve as a basis for a three-dimensional simulation model of coal combustion. In the future, further parameter studies will deepen the present knowledge of coal dust combustion under pressure and enable optimisation of the numerical models for simulation of industrial-scale systems for coal dust combustion under pressure. [Deutsch] Mit dem Flachflammenbrenner und dem KOALA-Reaktor der DMT stehen Versuchsapparaturen zur Verfuegung, mit deren Hilfe die Kohleumwandlungsprozesse bei hohen Temperaturen unter Druck und unter atmosphaerischen Bedingungen realistisch wiedergegeben werden. Das TOSCA-System erlaubt dabei die Bestimmung von Temperaturen, Groessen, Formen und Geschwindigkeiten der Brennstoffpartikel. Diese Daten liefern die Grundlage fuer die Erstellung eines dreidimensionalen Simulationsmodells zur Modellierung der Kohleverbrennung. In Zukunft werden weitere Parameterstudien das Verstaendnis der Kohlenstaubdruckverbrennung vertiefen und ein Optimierung der numerischen Modelle ermoeglichen, so dass die Simulation grosstechnischer Kohlenstaubdruckverbrennungsanlagen realisiert werden kann. (orig.)

  8. Rotation of Magnetization Derived from Brownian Relaxation in Magnetic Fluids of Different Viscosity Evaluated by Dynamic Hysteresis Measurements over a Wide Frequency Range

    Directory of Open Access Journals (Sweden)

    Satoshi Ota

    2016-09-01

    Full Text Available The dependence of magnetic relaxation on particle parameters, such as the size and anisotropy, has been conventionally discussed. In addition, the influences of external conditions, such as the intensity and frequency of the applied field, the surrounding viscosity, and the temperature on the magnetic relaxation have been researched. According to one of the basic theories regarding magnetic relaxation, the faster type of relaxation dominates the process. However, in this study, we reveal that Brownian and Néel relaxations coexist and that Brownian relaxation can occur after Néel relaxation despite having a longer relaxation time. To understand the mechanisms of Brownian rotation, alternating current (AC hysteresis loops were measured in magnetic fluids of different viscosities. These loops conveyed the amplitude and phase delay of the magnetization. In addition, the intrinsic loss power (ILP was calculated using the area of the AC hysteresis loops. The ILP also showed the magnetization response regarding the magnetic relaxation over a wide frequency range. To develop biomedical applications of magnetic nanoparticles, such as hyperthermia and magnetic particle imaging, it is necessary to understand the mechanisms of magnetic relaxation.

  9. High accuracy measurement of the $^{235}$U(n,f) reaction cross-section in the 10-30 keV neutron energy range

    CERN Multimedia

    The analysis of the neutron flux of n_TOF (in EAR1) revealed an anomaly in the 10-30 keV neutron energy range. While the flux extracted on the basis of the $^{6}$Li(n,t)$^{4}$He and $^{10}$B(n,$\\alpha$)$^{7}$Li reactions mostly agreed with each other and with the results of FLUKA simulations of the neutron beam, the one based on the $^{235}$U(n,f) reaction was found to be systematically lower, independently of the detection system used. A possible explanation is that the $^{235}$U(n,f) crosssection in that energy region, where in principle should be known with an uncertainty of 1%, may be systematically overestimated. Such a finding, which has a negligible influence on thermal reactors, would be important for future fast critical or subcritical reactors. Furthermore, its interest is more general, since the $^{235}$U(n,f) reaction is often used at that energy to determine the neutron flux, or as reference in measurements of fission cross section of other actinides. We propose to perform a high-accuracy, high-r...

  10. Using the American alligator and a repeated-measures design to place constraints on in vivo shoulder joint range of motion in dinosaurs and other fossil archosaurs.

    Science.gov (United States)

    Hutson, Joel D; Hutson, Kelda N

    2013-01-15

    Using the extant phylogenetic bracket of dinosaurs (crocodylians and birds), recent work has reported that elbow joint range of motion (ROM) studies of fossil dinosaur forearms may be providing conservative underestimates of fully fleshed in vivo ROM. As humeral ROM occupies a more central role in forelimb movements, the placement of quantitative constraints on shoulder joint ROM could improve fossil reconstructions. Here, we investigated whether soft tissues affect the more mobile shoulder joint in the same manner in which they affect elbow joint ROM in an extant archosaur. This test involved separately and repeatedly measuring humeral ROM in Alligator mississippiensis as soft tissues were dissected away in stages to bare bone. Our data show that the ROMs of humeral flexion and extension, as well as abduction and adduction, both show a statistically significant increase as flesh is removed, but then decrease when the bones must be physically articulated and moved until they separate from one another and/or visible joint surfaces. A similar ROM pattern is inferred for humeral pronation and supination. All final skeletonized ROMs were less than initial fully fleshed ROMs. These results are consistent with previously reported elbow joint ROM patterns from the extant phylogenetic bracket of dinosaurs. Thus, studies that avoid separation of complementary articular surfaces may be providing fossil shoulder joint ROMs that underestimate in vivo ROM in dinosaurs, as well as other fossil archosaurs.

  11. Measuring Relative Motions Across a Fault Using Seafloor Transponders Installed at Close Range to each Other Based on Differential GPS/Acoustic Technique

    Science.gov (United States)

    Kido, M.; Ashi, J.; Tsuji, T.; Tomita, F.

    2016-12-01

    Seafloor geodesy based on acoustic ranging technique is getting popular means to reveal crustal deformation beneath the ocean. GPS/acoustic technique can be applied to monitoring regional deformation or absolute position, while direct-path acoustic ranging can be applied to detecting localized strain or relative motion in a short distance ( 1-10 km). However the latter observation sometimes fails to keep the clearance of an acoustic path between the seafloor transponders because of topographic obstacle or of downward bending nature of the path due to vertical gradient of sound speed in deep-ocean. Especially at steep fault scarp, it is almost impossible to keep direct path between the top and bottom of the fault scarp. Even in such a situation, acoustic path to the sea surface might be always clear. Then we propose a new approach to monitor the relative motion of across a fault scarp using "differential" GPS/acoustic measurement, which account only for traveltime differences among the transponders. The advantages of this method are that: (1) uncertainty in sound speed in shallow water is almost canceled; (2) possible GPS error is also canceled; (3) picking error in traveltime detection is almost canceled; (4) only a pair of transponders can fully describe relative 3-dimensional motion. On the other hand the disadvantages are that: (5) data is not continuous but only campaign; (6) most advantages are only effective only for very short baseline (< 100-300 m). Our target being applied this method is a steep fault scarp near the Japan trench, which is expected as a surface expression of back thrust, in where time scale of fault activity is still controversial especially after the Tohoku earthquake. We have carefully installed three transponders across this scarp using a NSS system, which can remotely navigate instrument near the seafloor from a mother vessel based on video camera image. Baseline lengths among the transponders are 200-300 m at 3500 m depth. Initial

  12. Sensemaking e o Desenvolvimento de Redes de Relacionamentos de Negócios no Contexto das Empresas de Base Tecnológica

    Directory of Open Access Journals (Sweden)

    Ricardo Sérgio Gomes Vieira

    2012-06-01

    Full Text Available Nas últimas três décadas, questões relativas ao papel e à importância das redes sociais de negócio têm surgido como foco de amplo e acalorado debate entre acadêmicos e profissionais da Administração. Apesar da existência de diversos arcabouços conceituais ligados à Network Theory, o modelo Ator-Atividades-Recursos (AAR desenvolvido pelo IMP-Group tem sido amplamente utilizado numa variedade de contextos organizacionais. Neste artigo, utilizamos o AAR para investigar como oportunidades de negócios são identificadas por dirigentes de empresas de base tecnológica. Nesta pesquisa de natureza qualitativa, básica e de caráter exploratório-descritivo, foram realizadas entrevistas em profundidade. A análise de conteúdo foi adotada como método para interpretar os dados coletados pelas entrevistas. O principal resultado aponta para uma dinâmica coletiva desenvolvida nas redes de relacionamentos de negócios. Além disso, observam-se a importância e o papel do sensemaking em tal atividade. Em linhas gerais, o sensemaking é o processo pelo qual as pessoas geram sentido de suas experiências. Reflexões teóricas sobre os achados são discutidas e implicações para a academia e a prática organizacional, bem como indicações para futuras pesquisas são consideradas. ----- Sensemaking and Business Relationships Network Development in the Context of High-Tech Firms ----- ABSTRACT ----- In the last three decades, issues concerning the role and influence of business social networks have sprung up as the main focus of debate amongst academics and professionals from the Business Area. Although there have been many theoretical backgrounds bounded to Network Theory, the Actor-Activities-Resources model (AAR model developed by IMP-Group has been mostly adopted in a wide array of organizational contexts. Bearing this in mind, the AAR model was used to investigate how business opportunities are identifi ed by the CEOs of High-Tech Firms

  13. Photo-dynamics of the BLUF domain containing soluble adenylate cyclase (nPAC) from the amoeboflagellate Naegleria gruberi NEG-M strain

    Energy Technology Data Exchange (ETDEWEB)

    Penzkofer, A., E-mail: alfons.penzkofer@physik.uni-regensburg.de [Fakultaet fuer Physik, Universitaet Regensburg, Universitaetsstrasse 31, D-93053 Regensburg (Germany); Stierl, M.; Hegemann, P. [Institut fuer Biologie/Experimentelle Biophysik, Humboldt Universitaet zu Berlin, Invalidenstrasse 42, D-10115 Berlin (Germany); Kateriya, Suneel [Department of Biochemistry, University of Delhi South Campus, Benito Juarez Road, New Delhi 110021 (India)

    2011-08-25

    Graphical abstract: The photoactivated adenylyl cyclase (nPAC) from Naegleria gruberi was expressed heterologously in Escherichia coli and its photo-cycling dynamics was studied by optical absorption and fluorescence spectroscopy. Highlights: {yields} Photo-activated adenylyl cyclase (nPAC) from Naegleria gruberi NEG-M was expressed. {yields} Photodynamics of BLUF domain in BLUF sensor - cyclase actuator protein was studied. {yields} Photo-excitation caused BLUF photo-cycling and permanent protein re-conformation. {yields} Re-conformed protein enabled photo-induced flavin reduction by proton transfer. {yields} Fluorescence of flavin in dark- and light-adapted state of nPAC was characterized. - Abstract: The amoeboflagellate Naegleria gruberi NEG-M comprises a BLUF (blue light sensor using flavin) regulated adenylate cyclase (nPAC). The nPAC gene was expressed heterologously in Escherichia coli and the photo-dynamics of the nPAC protein was studied by optical absorption and fluorescence spectroscopy. Blue-light exposure of nPAC caused a typical BLUF-type photo-cycle behavior (spectral absorption red-shift, fluorescence quenching, absorption and fluorescence recovery in the dark). Additionally, time-delayed reversible photo-induced one-electron reduction of fully oxidized flavin (Fl{sub ox}) to semi-reduced flavin (FlH{sup {center_dot}}) occurred. Furthermore, photo-excitation of FlH{sup {center_dot}} caused irreversible electron transfer to fully reduced anionic flavin (FlH{sup -}). A photo-induced electron transfer from Tyr or Trp to flavin (Tyr{sup {center_dot}+}-Fl{sup {center_dot}-} or Trp{sup {center_dot}+}-Fl{sup {center_dot}-} radical ion-pair formation) is thought to cause H-bond restructuring responsible for BLUF-type photo-cycling and permanent protein re-conformation enabling photo-induced flavin reduction by proton transfer. Some photo-degradation of Fl{sub ox} to lumichrome was observed. A model of the photo-dynamics of nPAC is developed.

  14. A alavanca que move o mundo: o discurso da mídia de negócios sobre o capitalis