  1. A JPEG backward-compatible HDR image compression

    Science.gov (United States)

    Korshunov, Pavel; Ebrahimi, Touradj

    2012-10-01

    High Dynamic Range (HDR) imaging is expected to become one of the technologies that could shape next generation of consumer digital photography. Manufacturers are rolling out cameras and displays capable of capturing and rendering HDR images. The popularity and full public adoption of HDR content is however hindered by the lack of standards in evaluation of quality, file formats, and compression, as well as large legacy base of Low Dynamic Range (LDR) displays that are unable to render HDR. To facilitate wide spread of HDR usage, the backward compatibility of HDR technology with commonly used legacy image storage, rendering, and compression is necessary. Although many tone-mapping algorithms were developed for generating viewable LDR images from HDR content, there is no consensus on which algorithm to use and under which conditions. This paper, via a series of subjective evaluations, demonstrates the dependency of perceived quality of the tone-mapped LDR images on environmental parameters and image content. Based on the results of subjective tests, it proposes to extend JPEG file format, as the most popular image format, in a backward compatible manner to also deal with HDR pictures. To this end, the paper provides an architecture to achieve such backward compatibility with JPEG and demonstrates efficiency of a simple implementation of this framework when compared to the state of the art HDR image compression.

  2. HDR Image Quality Enhancement Based on Spatially Variant Retinal Response

    Directory of Open Access Journals (Sweden)

    Horiuchi Takahiko

    2010-01-01

    Full Text Available There is a growing demand for being able to display high dynamic range (HDR images on low dynamic range (LDR devices. Tone mapping is a process for enhancing HDR image quality on an LDR device by converting the tonal values of the original image from HDR to LDR. This paper proposes a new tone mapping algorithm for enhancing image quality by deriving a spatially-variant operator for imitating S-potential response in human retina, which efficiently improves local contrasts while conserving good global appearance. The proposed tone mapping operator is studied from a system construction point of view. It is found that the operator is regarded as a natural extension of the Retinex algorithm by adding a global adaptation process to the local adaptation. The feasibility of the proposed algorithm is examined in detail on experiments using standard HDR images and real HDR scene images, comparing with conventional tone mapping algorithms.

  3. High dynamic range (HDR) virtual bronchoscopy rendering for video tracking

    Science.gov (United States)

    Popa, Teo; Choi, Jae

    2007-03-01

    In this paper, we present the design and implementation of a new rendering method based on high dynamic range (HDR) lighting and exposure control. This rendering method is applied to create video images for a 3D virtual bronchoscopy system. One of the main optical parameters of a bronchoscope's camera is the sensor exposure. The exposure adjustment is needed since the dynamic range of most digital video cameras is narrower than the high dynamic range of real scenes. The dynamic range of a camera is defined as the ratio of the brightest point of an image to the darkest point of the same image where details are present. In a video camera exposure is controlled by shutter speed and the lens aperture. To create the virtual bronchoscopic images, we first rendered a raw image in absolute units (luminance); then, we simulated exposure by mapping the computed values to the values appropriate for video-acquired images using a tone mapping operator. We generated several images with HDR and others with low dynamic range (LDR), and then compared their quality by applying them to a 2D/3D video-based tracking system. We conclude that images with HDR are closer to real bronchoscopy images than those with LDR, and thus, that HDR lighting can improve the accuracy of image-based tracking.

  4. Color Calibration of HDR Image under a Known Illumination for Measuring Reflectance Property of Materials

    National Research Council Canada - National Science Library

    YOO, Hyunjin; KIM, Kang Y; LEE, Kwan H

    2009-01-01

    .... Hence, the HDR image can be used to measure the reflectance property of materials. In order to reproduce the original color of materials using this HDR image, characterization of HDR imaging is needed...

  5. HDR IMAGING FOR FEATURE DETECTION ON DETAILED ARCHITECTURAL SCENES

    Directory of Open Access Journals (Sweden)

    G. Kontogianni

    2015-02-01

    Full Text Available 3D reconstruction relies on accurate detection, extraction, description and matching of image features. This is even truer for complex architectural scenes that pose needs for 3D models of high quality, without any loss of detail in geometry or color. Illumination conditions influence the radiometric quality of images, as standard sensors cannot depict properly a wide range of intensities in the same scene. Indeed, overexposed or underexposed pixels cause irreplaceable information loss and degrade digital representation. Images taken under extreme lighting environments may be thus prohibitive for feature detection/extraction and consequently for matching and 3D reconstruction. High Dynamic Range (HDR images could be helpful for these operators because they broaden the limits of illumination range that Standard or Low Dynamic Range (SDR/LDR images can capture and increase in this way the amount of details contained in the image. Experimental results of this study prove this assumption as they examine state of the art feature detectors applied both on standard dynamic range and HDR images.

  6. Developing a multispectral HDR imaging module for a BRDF measurement system

    Science.gov (United States)

    Kim, Duck Bong; Seo, Myoung Kook; Kim, Kang Yeon; Lee, Kwan H.

    2010-08-01

    Most recent bidirectional reflectance distribution function (BRDF) measurement systems are the image-based that consist of a light source, a detector, and curved samples. They are useful for measuring the reflectance properties of a material but they have two major drawbacks. They suffer from high cost of BRDF acquisition and also give inaccurate results due to the limited use of spectral bands. In this paper, we propose a novel multispectral HDR imaging system and its efficient characterization method. It combines two promising technologies: high dynamic range (HDR) imaging and multispectral imaging to measure BRDF. We perform a full spectral recovery using camera response curves for each wavelength band and its analysis. For this, we use an HDR camera to capture HDR images and a liquid crystal tunable filter (LCTF) to generate multi-spectral images. Our method can provide an accurate color reproduction of metameric objects as well as a saturated image. Our multi-spectral HDR imaging system provides a very fast data acquisition time and also gives a low system setup cost compared to previous multi-spectral imaging systems and point-based commercial spectroradiometers. We verify the color accuracy of our multi-spectral HDR imaging system in terms of human vision and metamerism using colorimetric and spectral metric.

  7. HDR Pathological Image Enhancement Based on Improved Bias Field Correction and Guided Image Filter

    Science.gov (United States)

    Zhu, Ganzheng; Li, Siqi; Gong, Shang; Yang, Benqiang; Zhang, Libo

    2016-01-01

    Pathological image enhancement is a significant topic in the field of pathological image processing. This paper proposes a high dynamic range (HDR) pathological image enhancement method based on improved bias field correction and guided image filter (GIF). Firstly, a preprocessing including stain normalization and wavelet denoising is performed for Haematoxylin and Eosin (H and E) stained pathological image. Then, an improved bias field correction model is developed to enhance the influence of light for high-frequency part in image and correct the intensity inhomogeneity and detail discontinuity of image. Next, HDR pathological image is generated based on least square method using low dynamic range (LDR) image, H and E channel images. Finally, the fine enhanced image is acquired after the detail enhancement process. Experiments with 140 pathological images demonstrate the performance advantages of our proposed method as compared with related work. PMID:28116303

  8. The Ansel Adams zone system: HDR capture and range compression by chemical processing

    Science.gov (United States)

    McCann, John J.

    2010-02-01

    We tend to think of digital imaging and the tools of PhotoshopTM as a new phenomenon in imaging. We are also familiar with multiple-exposure HDR techniques intended to capture a wider range of scene information, than conventional film photography. We know about tone-scale adjustments to make better pictures. We tend to think of everyday, consumer, silver-halide photography as a fixed window of scene capture with a limited, standard range of response. This description of photography is certainly true, between 1950 and 2000, for instant films and negatives processed at the drugstore. These systems had fixed dynamic range and fixed tone-scale response to light. All pixels in the film have the same response to light, so the same light exposure from different pixels was rendered as the same film density. Ansel Adams, along with Fred Archer, formulated the Zone System, staring in 1940. It was earlier than the trillions of consumer photos in the second half of the 20th century, yet it was much more sophisticated than today's digital techniques. This talk will describe the chemical mechanisms of the zone system in the parlance of digital image processing. It will describe the Zone System's chemical techniques for image synthesis. It also discusses dodging and burning techniques to fit the HDR scene into the LDR print. Although current HDR imaging shares some of the Zone System's achievements, it usually does not achieve all of them.

  9. High dynamic range adaptive real-time smart camera: an overview of the HDR-ARTiST project

    Science.gov (United States)

    Lapray, Pierre-Jean; Heyrman, Barthélémy; Ginhac, Dominique

    2015-04-01

    Standard cameras capture only a fraction of the information that is visible to the human visual system. This is specifically true for natural scenes including areas of low and high illumination due to transitions between sunlit and shaded areas. When capturing such a scene, many cameras are unable to store the full Dynamic Range (DR) resulting in low quality video where details are concealed in shadows or washed out by sunlight. The imaging technique that can overcome this problem is called HDR (High Dynamic Range) imaging. This paper describes a complete smart camera built around a standard off-the-shelf LDR (Low Dynamic Range) sensor and a Virtex-6 FPGA board. This smart camera called HDR-ARtiSt (High Dynamic Range Adaptive Real-time Smart camera) is able to produce a real-time HDR live video color stream by recording and combining multiple acquisitions of the same scene while varying the exposure time. This technique appears as one of the most appropriate and cheapest solution to enhance the dynamic range of real-life environments. HDR-ARtiSt embeds real-time multiple captures, HDR processing, data display and transfer of a HDR color video for a full sensor resolution (1280 1024 pixels) at 60 frames per second. The main contributions of this work are: (1) Multiple Exposure Control (MEC) dedicated to the smart image capture with alternating three exposure times that are dynamically evaluated from frame to frame, (2) Multi-streaming Memory Management Unit (MMMU) dedicated to the memory read/write operations of the three parallel video streams, corresponding to the different exposure times, (3) HRD creating by combining the video streams using a specific hardware version of the Devebecs technique, and (4) Global Tone Mapping (GTM) of the HDR scene for display on a standard LCD monitor.

  10. An HDR imaging method with DTDI technology for push-broom cameras

    Science.gov (United States)

    Sun, Wu; Han, Chengshan; Xue, Xucheng; Lv, Hengyi; Shi, Junxia; Hu, Changhong; Li, Xiangzhi; Fu, Yao; Jiang, Xiaonan; Huang, Liang; Han, Hongyin

    2017-11-01

    Conventionally, high dynamic-range (HDR) imaging is based on taking two or more pictures of the same scene with different exposure. However, due to a high-speed relative motion between the camera and the scene, it is hard for this technique to be applied to push-broom remote sensing cameras. For the sake of HDR imaging in push-broom remote sensing applications, the present paper proposes an innovative method which can generate HDR images without redundant image sensors or optical components. Specifically, this paper adopts an area array CMOS (complementary metal oxide semiconductor) with the digital domain time-delay-integration (DTDI) technology for imaging, instead of adopting more than one row of image sensors, thereby taking more than one picture with different exposure. And then a new HDR image by fusing two original images with a simple algorithm can be achieved. By conducting the experiment, the dynamic range (DR) of the image increases by 26.02 dB. The proposed method is proved to be effective and has potential in other imaging applications where there is a relative motion between the cameras and scenes.

  11. Stereo Vision-Based High Dynamic Range Imaging Using Differently-Exposed Image Pair.

    Science.gov (United States)

    Park, Won-Jae; Ji, Seo-Won; Kang, Seok-Jae; Jung, Seung-Won; Ko, Sung-Jea

    2017-06-22

    In this paper, a high dynamic range (HDR) imaging method based on the stereo vision system is presented. The proposed method uses differently exposed low dynamic range (LDR) images captured from a stereo camera. The stereo LDR images are first converted to initial stereo HDR images using the inverse camera response function estimated from the LDR images. However, due to the limited dynamic range of the stereo LDR camera, the radiance values in under/over-exposed regions of the initial main-view (MV) HDR image can be lost. To restore these radiance values, the proposed stereo matching and hole-filling algorithms are applied to the stereo HDR images. Specifically, the auxiliary-view (AV) HDR image is warped by using the estimated disparity between initial the stereo HDR images and then effective hole-filling is applied to the warped AV HDR image. To reconstruct the final MV HDR, the warped and hole-filled AV HDR image is fused with the initial MV HDR image using the weight map. The experimental results demonstrate objectively and subjectively that the proposed stereo HDR imaging method provides better performance compared to the conventional method.

  12. Stereo Vision-Based High Dynamic Range Imaging Using Differently-Exposed Image Pair

    Directory of Open Access Journals (Sweden)

    Won-Jae Park

    2017-06-01

    Full Text Available In this paper, a high dynamic range (HDR imaging method based on the stereo vision system is presented. The proposed method uses differently exposed low dynamic range (LDR images captured from a stereo camera. The stereo LDR images are first converted to initial stereo HDR images using the inverse camera response function estimated from the LDR images. However, due to the limited dynamic range of the stereo LDR camera, the radiance values in under/over-exposed regions of the initial main-view (MV HDR image can be lost. To restore these radiance values, the proposed stereo matching and hole-filling algorithms are applied to the stereo HDR images. Specifically, the auxiliary-view (AV HDR image is warped by using the estimated disparity between initial the stereo HDR images and then effective hole-filling is applied to the warped AV HDR image. To reconstruct the final MV HDR, the warped and hole-filled AV HDR image is fused with the initial MV HDR image using the weight map. The experimental results demonstrate objectively and subjectively that the proposed stereo HDR imaging method provides better performance compared to the conventional method.

  13. Transillumination and HDR Imaging for Proximal Caries Detection.

    Science.gov (United States)

    Lederer, A; Kunzelmann, K H; Hickel, R; Litzenburger, F

    2018-02-01

    The purpose was to develop an in vitro model for the validation of near-infrared transillumination (NIRT) for proximal caries detection, to enhance NIRT with high-dynamic-range imaging (HDRI), and to compare both methods, using micro-computed tomography (µCT) as a reference standard. Both proximal surfaces of 53 healthy or decayed permanent human teeth were examined using the Diagnocam (DC) (KaVo) and NIRT with HDRI (NIRT-HDRI). NIRT was combined with HDRI to improve the diagnostic performance by reducing under- and overexposed image areas. For NIRT-HDRI, an exposure series was captured and merged into a single HDR image. A classification was applied according to lesion depth. All surfaces were assessed twice by 2 trained examiners, and additionally with µCT for validation. The Kappa statistic was used to calculate inter-rater reliability and agreement between DC and NIRT-HDRI. Inter-rater reliability (weighted Kappa, wκ) showed very good agreement for the DC (0.90) and NIRT-HDRI (0.96). The overall agreement (wκ) was almost perfect (0.85). In the individual categories (0 to 4), the agreement (simple Kappa) ranged from almost perfect (category 4) to moderate (1 and 2) to substantial (categories 0 and 3). Sensitivity and specificity of sound surfaces, enamel, and dentin caries ranged from 0.57 to 0.99 and were similar for both methods in the different categories. NIRT-HDRI had a higher sensitivity for sound surfaces and enamel caries, as well as a higher specificity for dentin caries. Regarding the obtained images, HDRI allowed for the detection of caries within a greater range of luminance levels, resulting in a more detailed visualization of structures without under- or overexposure. However, HDRI this did not improve the diagnostics significantly. Distinguishing between a processed demineralized enamel and dentin lesions appears to be a problem specific to NIRT and cannot be balanced using HDRI.

  14. Comparative Analysis between LDR and HDR Images for Automatic Fruit Recognition and Counting

    Directory of Open Access Journals (Sweden)

    Tatiana M. Pinho

    2017-01-01

    Full Text Available Precision agriculture is gaining an increasing interest in the current farming paradigm. This new production concept relies on the use of information technology (IT to provide a control and supervising structure that can lead to better management policies. In this framework, imaging techniques that provide visual information over the farming area play an important role in production status monitoring. As such, accurate representation of the gathered production images is a major concern, especially if those images are used in detection and classification tasks. Real scenes, observed in natural environment, present high dynamic ranges that cannot be represented by the common LDR (Low Dynamic Range devices. However, this issue can be handled by High Dynamic Range (HDR images since they have the ability to store luminance information similarly to the human visual system. In order to prove their advantage in image processing, a comparative analysis between LDR and HDR images, for fruits detection and counting, was carried out. The obtained results show that the use of HDR images improves the detection performance to more than 30% when compared to LDR.

  15. WE-F-BRD-01: HDR Brachytherapy II: Integrating Imaging with HDR

    Energy Technology Data Exchange (ETDEWEB)

    Craciunescu, O [Duke University Medical Center, Durham, NC (United States); Todor, D [Virginia Commonwealth University, Richmond, VA (United States); Leeuw, A de

    2014-06-15

    In recent years, with the advent of high/pulsed dose rate afterloading technology, advanced treatment planning systems, CT/MRI compatible applicators, and advanced imaging platforms, image-guided adaptive brachytherapy treatments (IGABT) have started to play an ever increasing role in modern radiation therapy. The most accurate way to approach IGABT treatment is to provide the infrastructure that combines in a single setting an appropriate imaging device, a treatment planning system, and a treatment unit. The Brachytherapy Suite is not a new concept, yet the modern suites are incorporating state-of-the-art imaging (MRI, CBCT equipped simulators, CT, and /or US) that require correct integration with each other and with the treatment planning and delivery systems. Arguably, an MRI-equipped Brachytherapy Suite is the ideal setup for real-time adaptive brachytherapy treatments. The main impediment to MRI-IGABT adoption is access to MRI scanners. Very few radiation oncology departments currently house MRI scanners, and even fewer in a dedicated Brachytherapy Suite. CBCT equipped simulators are increasingly offered by manufacturers as part of a Brachytherapy Suite installation. If optimized, images acquired can be used for treatment planning, or can be registered with other imaging modalities. This infrastructure is relevant for all forms of brachytherapy, especially those utilizing multi-fractionated courses of treatment such as prostate and cervix. Moreover, for prostate brachytherapy, US imaging systems can be part of the suite to allow for real-time HDR/LDR treatments. Learning Objectives: Understand the adaptive workflow of MR-based IGBT for cervical cancer. Familiarize with commissioning aspects of a CBCT equipped simulator with emphasis on brachytherapy applications Learn about the current status and future developments in US-based prostate brachytherapy.

  16. MO-B-BRC-00: Prostate HDR Treatment Planning - Considering Different Imaging Modalities

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2016-06-15

    Brachytherapy has proven to be an effective treatment option for prostate cancer. Initially, prostate brachytherapy was delivered through permanently implanted low dose rate (LDR) radioactive sources; however, high dose rate (HDR) temporary brachytherapy for prostate cancer is gaining popularity. Needle insertion during prostate brachytherapy is most commonly performed under ultrasound (U/S) guidance; however, treatment planning may be performed utilizing several imaging modalities either in an intra- or post-operative setting. During intra-operative prostate HDR, the needles are imaged during implantation, and planning may be performed in real time. At present, the most common imaging modality utilized for intra-operative prostate HDR is U/S. Alternatively, in the post-operative setting, following needle implantation, patients may be simulated with computed tomography (CT) or magnetic resonance imaging (MRI). Each imaging modality and workflow provides its share of benefits and limitations. Prostate HDR has been adopted in a number of cancer centers across the nation. In this educational session, we will explore the role of U/S, CT, and MRI in HDR prostate brachytherapy. Example workflows and operational details will be shared, and we will discuss how to establish a prostate HDR program in a clinical setting. Learning Objectives: Review prostate HDR techniques based on the imaging modality Discuss the challenges and pitfalls introduced by the three imagebased options for prostate HDR brachytherapy Review the QA process and learn about the development of clinical workflows for these imaging options at different institutions.

  17. High dynamic range imaging sensors and architectures

    CERN Document Server

    Darmont, Arnaud

    2013-01-01

    Illumination is a crucial element in many applications, matching the luminance of the scene with the operational range of a camera. When luminance cannot be adequately controlled, a high dynamic range (HDR) imaging system may be necessary. These systems are being increasingly used in automotive on-board systems, road traffic monitoring, and other industrial, security, and military applications. This book provides readers with an intermediate discussion of HDR image sensors and techniques for industrial and non-industrial applications. It describes various sensor and pixel architectures capable

  18. The high dynamic range pixel array detector (HDR-PAD): Concept and design

    Energy Technology Data Exchange (ETDEWEB)

    Shanks, Katherine S.; Philipp, Hugh T.; Weiss, Joel T.; Becker, Julian; Tate, Mark W. [Laboratory of Atomic and Solid State Physics, Cornell University, Ithaca, NY 14853 (United States); Gruner, Sol M., E-mail: smg26@cornell.edu [Laboratory of Atomic and Solid State Physics, Cornell University, Ithaca, NY 14853 (United States); Cornell High Energy Synchrotron Source (CHESS), Cornell University, Ithaca, NY 14853 (United States)

    2016-07-27

    Experiments at storage ring light sources as well as at next-generation light sources increasingly require detectors capable of high dynamic range operation, combining low-noise detection of single photons with large pixel well depth. XFEL sources in particular provide pulse intensities sufficiently high that a purely photon-counting approach is impractical. The High Dynamic Range Pixel Array Detector (HDR-PAD) project aims to provide a dynamic range extending from single-photon sensitivity to 10{sup 6} photons/pixel in a single XFEL pulse while maintaining the ability to tolerate a sustained flux of 10{sup 11} ph/s/pixel at a storage ring source. Achieving these goals involves the development of fast pixel front-end electronics as well as, in the XFEL case, leveraging the delayed charge collection due to plasma effects in the sensor. A first prototype of essential electronic components of the HDR-PAD readout ASIC, exploring different options for the pixel front-end, has been fabricated. Here, the HDR-PAD concept and preliminary design will be described.

  19. The general solution to HDR rendering

    Science.gov (United States)

    McCann, John

    2012-03-01

    Our High-Dynamic-Range (HDR) world is the result of nonuniform illumination. We like to believe that 21st century technology makes it possible to accurately reproduce any scene. On further study, we find that scene rendition remains a best compromise. Despite all the remarkable accomplishments in digital imaging, we cannot capture and reproduce the light in the world exactly. With still further study, we find that accurate reproduction is not necessary. We need an interdisciplinary study of image making - painting, photography and image processing - to find the general solution. HDR imaging would be very confusing, without two observations that resolve many paradoxes. First, optical veiling glare, that depends on the scene content, severely limits the range of light on cameras' sensors, and on retinas. Second, the neural spatial image processing in human vision counteracts glare with variable scene dependent responses. The counter actions of these optical and neural processes shape the goals of HDR imaging. Successful HDR increases the apparent contrast of details lost in the shadows and highlights of conventional images. They change the spatial relationships by altering the local contrast of edges and gradients. The goal of HDR imaging is displaying calculated appearance, rather than accurate light reproduction. By using this strategy we can develop universal algorithms that process all images, LDR and HDR, achromatic and color, by mimicking human vision. The study of the general solution for HDR imaging incorporates painting photography, vision research, color constancy and digital image processing.

  20. Context-dependent JPEG backward-compatible high-dynamic range image compression

    Science.gov (United States)

    Korshunov, Pavel; Ebrahimi, Touradj

    2013-10-01

    High-dynamic range (HDR) imaging is expected, together with ultrahigh definition and high-frame rate video, to become a technology that may change photo, TV, and film industries. Many cameras and displays capable of capturing and rendering both HDR images and video are already available in the market. The popularity and full-public adoption of HDR content is, however, hindered by the lack of standards in evaluation of quality, file formats, and compression, as well as large legacy base of low-dynamic range (LDR) displays that are unable to render HDR. To facilitate the wide spread of HDR usage, the backward compatibility of HDR with commonly used legacy technologies for storage, rendering, and compression of video and images are necessary. Although many tone-mapping algorithms are developed for generating viewable LDR content from HDR, there is no consensus of which algorithm to use and under which conditions. We, via a series of subjective evaluations, demonstrate the dependency of the perceptual quality of the tone-mapped LDR images on the context: environmental factors, display parameters, and image content itself. Based on the results of subjective tests, it proposes to extend JPEG file format, the most popular image format, in a backward compatible manner to deal with HDR images also. An architecture to achieve such backward compatibility with JPEG is proposed. A simple implementation of lossy compression demonstrates the efficiency of the proposed architecture compared with the state-of-the-art HDR image compression.

  1. BrachyView, a novel in-body imaging system for HDR prostate brachytherapy: Experimental evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Safavi-Naeini, M.; Han, Z.; Alnaghy, S.; Cutajar, D.; Petasecca, M.; Lerch, M. L. F.; Rosenfeld, A. B., E-mail: anatoly@uow.edu.au [Centre for Medical Radiation Physics, University of Wollongong, Wollongong 2522 (Australia); Franklin, D. R. [Faculty of Engineering and Information Technology, University of Technology, Sydney 2007 (Australia); Bucci, J. [St George Hospital Cancer Care Centre, Kogarah 2217 (Australia); Carrara, M. [Fondazione IRCCS Istituto Nazionale dei Tumori, Milan 20133 (Italy); Zaider, M. [Memorial Sloan Kettering Cancer Center, New York, New York 10065 (United States)

    2015-12-15

    Purpose: This paper presents initial experimental results from a prototype of high dose rate (HDR) BrachyView, a novel in-body source tracking system for HDR brachytherapy based on a multipinhole tungsten collimator and a high resolution pixellated silicon detector array. The probe and its associated position estimation algorithms are validated and a comprehensive evaluation of the accuracy of its position estimation capabilities is presented. Methods: The HDR brachytherapy source is moved through a sequence of positions in a prostate phantom, for various displacements in x, y, and z. For each position, multiple image acquisitions are performed, and source positions are reconstructed. Error estimates in each dimension are calculated at each source position and combined to calculate overall positioning errors. Gafchromic film is used to validate the accuracy of source placement within the phantom. Results: More than 90% of evaluated source positions were estimated with an error of less than one millimeter, with the worst-case error being 1.3 mm. Experimental results were in close agreement with previously published Monte Carlo simulation results. Conclusions: The prototype of HDR BrachyView demonstrates a satisfactory level of accuracy in its source position estimation, and additional improvements are achievable with further refinement of HDR BrachyView’s image processing algorithms.

  2. Video Enhancement and Dynamic Range Control of HDR Sequences for Automotive Applications

    Directory of Open Access Journals (Sweden)

    Giovanni Ramponi

    2007-01-01

    Full Text Available CMOS video cameras with high dynamic range (HDR output are particularly suitable for driving assistance applications, where lighting conditions can strongly vary, going from direct sunlight to dark areas in tunnels. However, common visualization devices can only handle a low dynamic range, and thus a dynamic range reduction is needed. Many algorithms have been proposed in the literature to reduce the dynamic range of still pictures. Anyway, extending the available methods to video is not straightforward, due to the peculiar nature of video data. We propose an algorithm for both reducing the dynamic range of video sequences and enhancing its appearance, thus improving visual quality and reducing temporal artifacts. We also provide an optimized version of our algorithm for a viable hardware implementation on an FPGA. The feasibility of this implementation is demonstrated by means of a case study.

  3. Spatial imaging in color and HDR: prometheus unchained

    Science.gov (United States)

    McCann, John J.

    2013-03-01

    The Human Vision and Electronic Imaging Conferences (HVEI) at the IS and T/SPIE Electronic Imaging meetings have brought together research in the fundamentals of both vision and digital technology. This conference has incorporated many color disciplines that have contributed to the theory and practice of today's imaging: color constancy, models of vision, digital output, high-dynamic-range imaging, and the understanding of perceptual mechanisms. Before digital imaging, silver halide color was a pixel-based mechanism. Color films are closely tied to colorimetry, the science of matching pixels in a black surround. The quanta catch of the sensitized silver salts determines the amount of colored dyes in the final print. The rapid expansion of digital imaging over the past 25 years has eliminated the limitations of using small local regions in forming images. Spatial interactions can now generate images more like vision. Since the 1950's, neurophysiology has shown that post-receptor neural processing is based on spatial interactions. These results reinforced the findings of 19th century experimental psychology. This paper reviews the role of HVEI in color, emphasizing the interaction of research on vision and the new algorithms and processes made possible by electronic imaging.

  4. Comparing subjective and objective quality assessment of HDR images compressed with JPEG-XT

    DEFF Research Database (Denmark)

    Mantel, Claire; Ferchiu, Stefan Catalin; Forchhammer, Søren

    2014-01-01

    In this paper a subjective test in which participants evaluate the quality of JPEG-XT compressed HDR images is presented. Results show that for the selected test images and display, the subjective quality reached its saturation point starting around 3bpp. Objective evaluations are obtained by app...... the best performance with the limit that it does not capture the quality saturation. The usage of the gamma correction prior to applying metrics depends on the characteristics of each objective metric.......In this paper a subjective test in which participants evaluate the quality of JPEG-XT compressed HDR images is presented. Results show that for the selected test images and display, the subjective quality reached its saturation point starting around 3bpp. Objective evaluations are obtained...... by applying a model of the display and providing the modeled images to three objective metrics dedicated to HDR content. Objective grades are compared with subjective data both in physical domain and using a gamma correction to approximate perceptually uniform luminance coding. The MRSE metric obtains...

  5. Joint focus stacking and high dynamic range imaging

    Science.gov (United States)

    Qian, Qinchun; Gunturk, Bahadir K.; Batur, Aziz U.

    2013-01-01

    Focus stacking and high dynamic range (HDR) imaging are two paradigms of computational photography. Focus stacking aims to produce an image with greater depth of field (DOF) from a set of images taken with different focus distances, whereas HDR imaging aims to produce an image with higher dynamic range from a set of images taken with different exposure settings. In this paper, we present an algorithm which combines focus stacking and HDR imaging in order to produce an image with both higher dynamic range and greater DOF than any of the input images. The proposed algorithm includes two main parts: (i) joint photometric and geometric registration and (ii) joint focus stacking and HDR image creation. In the first part, images are first photometrically registered using an algorithm that is insensitive to small geometric variations, and then geometrically registered using an optical flow algorithm. In the second part, images are merged through weighted averaging, where the weights depend on both local sharpness and exposure information. We provide experimental results with real data to illustrate the algorithm. The algorithm is also implemented on a smartphone with Android operating system.

  6. Interactive, multi-modality image registrations for combined MRI/MRSI-planned HDR prostate brachytherapy

    Directory of Open Access Journals (Sweden)

    Galen Reed

    2011-03-01

    Full Text Available Purpose: This study presents the steps and criteria involved in the series of image registrations used clinically during the planning and dose delivery of focal high dose-rate (HDR brachytherapy of the prostate. Material and methods: Three imaging modalities – Magnetic Resonance Imaging (MRI, Magnetic Resonance Spectroscopic Imaging (MRSI, and Computed Tomography (CT – were used at different steps during the process. MRSI is used for identification of dominant intraprosatic lesions (DIL. A series of rigid and nonrigid transformations were applied to the data to correct for endorectal-coil-induced deformations and for alignment with the planning CT. Mutual information was calculated as a morphing metric. An inverse planning optimization algorithm was applied to boost dose to the DIL while providing protection to the urethra, penile bulb, rectum, and bladder. Six prostate cancer patients were treated using this protocol. Results: The morphing algorithm successfully modeled the probe-induced prostatic distortion. Mutual information calculated between the morphed images and images acquired without the endorectal probe showed a significant (p = 0.0071 increase to that calculated between the unmorphed images and images acquired without the endorectal probe. Both mutual information and visual inspection serve as effective diagnostics of image morphing. The entire procedure adds less than thirty minutes to the treatment planning. Conclusion: This work demonstrates the utility of image transformations and registrations to HDR brachytherapy of prostate cancer.

  7. Tone compatibility between HDR displays

    Science.gov (United States)

    Bist, Cambodge; Cozot, Rémi; Madec, Gérard; Ducloux, Xavier

    2016-09-01

    High Dynamic Range (HDR) is the latest trend in television technology and we expect an in ux of HDR capable consumer TVs in the market. Initial HDR consumer displays will operate on a peak brightness of about 500-1000 nits while in the coming years display peak brightness is expected to go beyond 1000 nits. However, professionally graded HDR content can range from 1000 to 4000 nits. As with Standard Dynamic Range (SDR) content, we can expect HDR content to be available in variety of lighting styles such as low key, medium key and high key video. This raises concerns over tone-compatibility between HDR displays especially when adapting to various lighting styles. It is expected that dynamic range adaptation between HDR displays uses similar techniques as found with tone mapping and tone expansion operators. In this paper, we survey simple tone mapping methods of 4000 nits color-graded HDR content for 1000 nits HDR displays. We also investigate tone expansion strategies when HDR content graded in 1000 nits is displayed on 4000 nits HDR monitors. We conclude that the best tone reproduction technique between HDR displays strongly depends on the lighting style of the content.

  8. Forward and backward tone mapping of high dynamic range images based on subband architecture

    Science.gov (United States)

    Bouzidi, Ines; Ouled Zaid, Azza

    2015-01-01

    This paper presents a novel High Dynamic Range (HDR) tone mapping (TM) system based on sub-band architecture. Standard wavelet filters of Daubechies, Symlets, Coiflets and Biorthogonal were used to estimate the proposed system performance in terms of Low Dynamic Range (LDR) image quality and reconstructed HDR image fidelity. During TM stage, the HDR image is firstly decomposed in sub-bands using symmetrical analysis-synthesis filter bank. The transform coefficients are then rescaled using a predefined gain map. The inverse Tone Mapping (iTM) stage is straightforward. Indeed, the LDR image passes through the same sub-band architecture. But, instead of reducing the dynamic range, the LDR content is boosted to an HDR representation. Moreover, in our TM sheme, we included an optimization module to select the gain map components that minimize the reconstruction error, and consequently resulting in high fidelity HDR content. Comparisons with recent state-of-the-art methods have shown that our method provides better results in terms of visual quality and HDR reconstruction fidelity using objective and subjective evaluations.

  9. An integrated system for clinical treatment verification of HDR prostate brachytherapy combining source tracking with pretreatment imaging.

    Science.gov (United States)

    Smith, Ryan L; Hanlon, Max; Panettieri, Vanessa; Millar, Jeremy L; Matheson, Bronwyn; Haworth, Annette; Franich, Rick D

    2017-09-22

    agreed with the treatment plan on average by 1.5 mm and were identifiable as a predominantly inferior shift. The source tracking was performed during treatment delivery, and for the same case, the mean deviation from the planned dwell positions was 1.9 mm (max = 4.9 mm) for 280 positions across all catheters. We have implemented our noninvasive treatment verification system based on an FPD in the clinical environment. The device is integrated into a patient treatment couch, and the process is now included in the routine clinical treatment procedure with minor impact on workflow. The system which combines both 2D pretreatment imaging and HDR 2D source tracking provides a range of information that can be used for comprehensive treatment verification. The system has the potential to meaningfully improve safety standards by allowing widespread adoption of routine treatment verification in HDR brachytherapy. Copyright © 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  10. Depth maps and high-dynamic range image generation from alternating exposure multiview images

    Science.gov (United States)

    Heo, Yong Seok; Lee, Kyoung Mu; Lee, Sang Uk

    2017-07-01

    For stereo matching, it is hard to find accurate correspondence for saturated regions, such as too dark or too bright regions, because there is rarely reliable information to match. In this situation, conventional high-dynamic range (HDR) imaging techniques combining multiple exposures for each viewpoint can be adopted to generate well-exposed stereo images. This approach is, however, time-consuming and needs much memory to store multiple exposures for each viewpoint. We propose an efficient method to generate HDR multiview images as well as corresponding accurate depth maps. First, we take a single exposure for each viewpoint with alternating exposure setting, such as short and long exposure, as functions of viewpoint changes. Then, we compute an initial depth map for each view only using neighboring images that have the same exposure. To reduce the error of the initial depth maps for the saturated regions, we adopt the fusion move algorithm fusing neighboring depth maps that have different error regions. Finally, using the enhanced depth maps, we generate artifact-free and sharp HDR images using the joint bilateral filtering and a detail-transfer technique. Experimental results show that our method produces both consistent HDR images and accurate depth maps for various indoor and outdoor multiview images.

  11. Long range image enhancement

    CSIR Research Space (South Africa)

    Duvenhage, B

    2015-11-01

    Full Text Available and Vision Computing, Auckland, New Zealand, 23-24 November 2015 Long Range Image Enhancement Bernardt Duvenhage Council for Scientific and Industrial Research South Africa Email: bduvenhage@csir.co.za Abstract Turbulent pockets of air...

  12. New segmentation-based tone mapping algorithm for high dynamic range image

    Science.gov (United States)

    Duan, Weiwei; Guo, Huinan; Zhou, Zuofeng; Huang, Huimin; Cao, Jianzhong

    2017-07-01

    The traditional tone mapping algorithm for the display of high dynamic range (HDR) image has the drawback of losing the impression of brightness, contrast and color information. To overcome this phenomenon, we propose a new tone mapping algorithm based on dividing the image into different exposure regions in this paper. Firstly, the over-exposure region is determined using the Local Binary Pattern information of HDR image. Then, based on the peak and average gray of the histogram, the under-exposure and normal-exposure region of HDR image are selected separately. Finally, the different exposure regions are mapped by differentiated tone mapping methods to get the final result. The experiment results show that the proposed algorithm achieve the better performance both in visual quality and objective contrast criterion than other algorithms.

  13. HDR video synthesis for vision systems in dynamic scenes

    Science.gov (United States)

    Shopovska, Ivana; Jovanov, Ljubomir; Goossens, Bart; Philips, Wilfried

    2016-09-01

    High dynamic range (HDR) image generation from a number of differently exposed low dynamic range (LDR) images has been extensively explored in the past few decades, and as a result of these efforts a large number of HDR synthesis methods have been proposed. Since HDR images are synthesized by combining well-exposed regions of the input images, one of the main challenges is dealing with camera or object motion. In this paper we propose a method for the synthesis of HDR video from a single camera using multiple, differently exposed video frames, with circularly alternating exposure times. One of the potential applications of the system is in driver assistance systems and autonomous vehicles, involving significant camera and object movement, non- uniform and temporally varying illumination, and the requirement of real-time performance. To achieve these goals simultaneously, we propose a HDR synthesis approach based on weighted averaging of aligned radiance maps. The computational complexity of high-quality optical flow methods for motion compensation is still pro- hibitively high for real-time applications. Instead, we rely on more efficient global projective transformations to solve camera movement, while moving objects are detected by thresholding the differences between the trans- formed and brightness adapted images in the set. To attain temporal consistency of the camera motion in the consecutive HDR frames, the parameters of the perspective transformation are stabilized over time by means of computationally efficient temporal filtering. We evaluated our results on several reference HDR videos, on synthetic scenes, and using 14-bit raw images taken with a standard camera.

  14. Medically inoperable endometrial cancer in patients with a high body mass index (BMI): Patterns of failure after 3-D image-based high dose rate (HDR) brachytherapy.

    Science.gov (United States)

    Acharya, Sahaja; Esthappan, Jacqueline; Badiyan, Shahed; DeWees, Todd A; Tanderup, Kari; Schwarz, Julie K; Grigsby, Perry W

    2016-01-01

    High BMI is a reason for medical inoperability in patients with endometrial cancer in the United States. Definitive radiation is an alternative therapy for these patients; however, data on patterns of failure after definitive radiotherapy are lacking. We describe the patterns of failure after definitive treatment with 3-D image-based high dose rate (HDR) brachytherapy for medically inoperable endometrial cancer. Forty-three consecutive patients with endometrial cancer FIGO stages I-III were treated definitively with HDR brachytherapy with or without external beam radiation therapy. Cumulative incidence of failures was estimated and prognostic variables were identified Mean follow up was 29.7 months. Median BMI was 50.2 kg/m(2) (range: 25.1-104 kg/m(2)). The two-year overall survival was 65.2%. The two-year cumulative incidence of pelvic and distant failures was 8.3% and 13.5%, respectively. Grade 3 disease was associated with a higher risk of all-failures (Hazard Ratio [HR]: 4.67, 95% CI: 1.04-20.9, p=0.044). The incidence of acute Grade 3 GI/GU toxicities was 4.6%. Pelvic failure at two years was less than 10%. Patients with grade 3 disease were more likely to experience disease failure and may warrant closer follow up. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  15. Evaluation of the effectiveness of HDR tone-mapping operators for photogrammetric applications

    Directory of Open Access Journals (Sweden)

    Rossella Suma

    2016-11-01

    Full Text Available The ability of High Dynamic Range (HDR imaging to capture the full range of lighting in a scene has meant that it is being increasingly used for Cultural Heritage (CH applications. Photogrammetric techniques allow the semi-automatic production of 3D models from a sequence of images. Current photogrammetric methods are not always effective in reconstructing images under harsh lighting conditions, as significant geometric details may not have been captured accurately within under- and over-exposed regions of the image. HDR imaging offers the possibility to overcome this limitation, however the HDR images need to be tone mapped before they can be used within existing photogrammetric algorithms. In this paper we evaluate four different HDR tone-mapping operators (TMOs that have been used to convert raw HDR images into a format suitable for state-of-the-art algorithms, and in particular keypoint detection techniques. The evaluation criteria used are the number of keypoints, the number of valid matches achieved and the repeatability rate. The comparison considers two local and two global TMOs. HDR data from four CH sites were used: Kaisariani Monastery (Greece, Asinou Church (Cyprus, Château des Baux (France and Buonconsiglio Castle (Italy.

  16. Medically inoperable endometrial cancer in patients with a high body mass index (BMI): Patterns of failure after 3-D image-based high dose rate (HDR) brachytherapy

    DEFF Research Database (Denmark)

    Acharya, Sahaja; Esthappan, Jacqueline; Badiyan, Shahed

    2016-01-01

    BACKGROUND AND PURPOSE: High BMI is a reason for medical inoperability in patients with endometrial cancer in the United States. Definitive radiation is an alternative therapy for these patients; however, data on patterns of failure after definitive radiotherapy are lacking. We describe...... the patterns of failure after definitive treatment with 3-D image-based high dose rate (HDR) brachytherapy for medically inoperable endometrial cancer. MATERIALS AND METHODS: Forty-three consecutive patients with endometrial cancer FIGO stages I-III were treated definitively with HDR brachytherapy...

  17. Evaluating HDR photos using Web 2.0 technology

    Science.gov (United States)

    Qiu, Guoping; Mei, Yujie; Duan, Jiang

    2011-01-01

    High dynamic range (HDR) photography is an emerging technology that has the potential to dramatically enhance the visual quality and realism of digital photos. One of the key technical challenges of HDR photography is displaying HDR photos on conventional devices through tone mapping or dynamic range compression. Although many different tone mapping techniques have been developed in recent years, evaluating tone mapping operators prove to be extremely difficult. Web2.0, social media and crowd-sourcing are emerging Internet technologies which can be harnessed to harvest the brain power of the mass to solve difficult problems in science, engineering and businesses. Paired comparison is used in the scientific study of preferences and attitudes and has been shown to be capable of obtaining an interval-scale ordering of items along a psychometric dimension such as preference or importance. In this paper, we exploit these technologies for evaluating HDR tone mapping algorithms. We have developed a Web2.0 style system that enables Internet users from anywhere to evaluate tone mapped HDR photos at any time. We adopt a simple paired comparison protocol, Internet users are presented a pair of tone mapped images and are simply asked to select the one that they think is better or click a "no difference" button. These user inputs are collected in the web server and analyzed by a rank aggregation algorithm which ranks the tone mapped photos according to the votes they received. We present experimental results which demonstrate that the emerging Internet technologies can be exploited as a new paradigm for evaluating HDR tone mapping algorithms. The advantages of this approach include the potential of collecting large user inputs under a variety of viewing environments rather than limited user participation under controlled laboratory environments thus enabling more robust and reliable quality assessment. We also present data analysis to correlate user generated qualitative

  18. An objective method for High Dynamic Range source content selection

    DEFF Research Database (Denmark)

    Narwaria, Manish; Mantel, Claire; Da Silva, Matthieu Perreira

    2014-01-01

    With the aim of improving the immersive experience of the end user, High Dynamic Range (HDR) imaging has been gaining popularity. Therefore, proper validation and performance benchmarking of HDR processing algorithms is a key step towards standardization and commercial deployment. A crucial compo...... visible errors on contrast reduction. This information is subsequently analyzed via fuzzy clustering to enable a probabilistic interpretation. To evaluate the proposed approach, we performed an experimental study on a large set of publicly available HDR images....

  19. HDR Efex Pro After the Shoot

    CERN Document Server

    Sholik, Stan

    2011-01-01

    A concise, on-the-go guide to the new HDR Efex Pro imaging toolkit for photographers Now that you've gone mobile and HDR, you want to be able to download and enhance your favorite photos on the run, without having to return to the mother ship (i.e., your desktop computer). This book shows you just how to do that using the amazing HDR Efex Pro, the image editing toolset from Nik Software. In brilliant color and using plenty of show-stopping examples, this practical guide explains all tools and features. Follow numbered steps and you'll soon be handling things like alignment, ghosting control, h

  20. HDR ühest kaadrist? / Janno Loide

    Index Scriptorium Estoniae

    Loide, Janno

    2008-01-01

    HDR-töötluse (High dynamic range - pildi kõrge dünaamiline ulatus) ja toonide kohandamise (tone mapping) meetodite kasutamisest pildi digitaalsel salvestusel ning sobiva hele-tumeduse leidmisel loodusfotode parema kvaliteedi saamiseks

  1. MO-B-BRC-04: MRI-Based Prostate HDR

    Energy Technology Data Exchange (ETDEWEB)

    Mourtada, F. [Christiana Care Hospital (United States)

    2016-06-15

    Brachytherapy has proven to be an effective treatment option for prostate cancer. Initially, prostate brachytherapy was delivered through permanently implanted low dose rate (LDR) radioactive sources; however, high dose rate (HDR) temporary brachytherapy for prostate cancer is gaining popularity. Needle insertion during prostate brachytherapy is most commonly performed under ultrasound (U/S) guidance; however, treatment planning may be performed utilizing several imaging modalities either in an intra- or post-operative setting. During intra-operative prostate HDR, the needles are imaged during implantation, and planning may be performed in real time. At present, the most common imaging modality utilized for intra-operative prostate HDR is U/S. Alternatively, in the post-operative setting, following needle implantation, patients may be simulated with computed tomography (CT) or magnetic resonance imaging (MRI). Each imaging modality and workflow provides its share of benefits and limitations. Prostate HDR has been adopted in a number of cancer centers across the nation. In this educational session, we will explore the role of U/S, CT, and MRI in HDR prostate brachytherapy. Example workflows and operational details will be shared, and we will discuss how to establish a prostate HDR program in a clinical setting. Learning Objectives: Review prostate HDR techniques based on the imaging modality Discuss the challenges and pitfalls introduced by the three imagebased options for prostate HDR brachytherapy Review the QA process and learn about the development of clinical workflows for these imaging options at different institutions.

  2. MO-B-BRC-03: CT-Based Prostate HDR

    Energy Technology Data Exchange (ETDEWEB)

    Zoberi, J. [Washington University School of Medicine (United States)

    2016-06-15

    Brachytherapy has proven to be an effective treatment option for prostate cancer. Initially, prostate brachytherapy was delivered through permanently implanted low dose rate (LDR) radioactive sources; however, high dose rate (HDR) temporary brachytherapy for prostate cancer is gaining popularity. Needle insertion during prostate brachytherapy is most commonly performed under ultrasound (U/S) guidance; however, treatment planning may be performed utilizing several imaging modalities either in an intra- or post-operative setting. During intra-operative prostate HDR, the needles are imaged during implantation, and planning may be performed in real time. At present, the most common imaging modality utilized for intra-operative prostate HDR is U/S. Alternatively, in the post-operative setting, following needle implantation, patients may be simulated with computed tomography (CT) or magnetic resonance imaging (MRI). Each imaging modality and workflow provides its share of benefits and limitations. Prostate HDR has been adopted in a number of cancer centers across the nation. In this educational session, we will explore the role of U/S, CT, and MRI in HDR prostate brachytherapy. Example workflows and operational details will be shared, and we will discuss how to establish a prostate HDR program in a clinical setting. Learning Objectives: Review prostate HDR techniques based on the imaging modality Discuss the challenges and pitfalls introduced by the three imagebased options for prostate HDR brachytherapy Review the QA process and learn about the development of clinical workflows for these imaging options at different institutions.

  3. MO-B-BRC-02: Ultrasound Based Prostate HDR

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Z. [Duke University Medical Center (United States)

    2016-06-15

    Brachytherapy has proven to be an effective treatment option for prostate cancer. Initially, prostate brachytherapy was delivered through permanently implanted low dose rate (LDR) radioactive sources; however, high dose rate (HDR) temporary brachytherapy for prostate cancer is gaining popularity. Needle insertion during prostate brachytherapy is most commonly performed under ultrasound (U/S) guidance; however, treatment planning may be performed utilizing several imaging modalities either in an intra- or post-operative setting. During intra-operative prostate HDR, the needles are imaged during implantation, and planning may be performed in real time. At present, the most common imaging modality utilized for intra-operative prostate HDR is U/S. Alternatively, in the post-operative setting, following needle implantation, patients may be simulated with computed tomography (CT) or magnetic resonance imaging (MRI). Each imaging modality and workflow provides its share of benefits and limitations. Prostate HDR has been adopted in a number of cancer centers across the nation. In this educational session, we will explore the role of U/S, CT, and MRI in HDR prostate brachytherapy. Example workflows and operational details will be shared, and we will discuss how to establish a prostate HDR program in a clinical setting. Learning Objectives: Review prostate HDR techniques based on the imaging modality Discuss the challenges and pitfalls introduced by the three imagebased options for prostate HDR brachytherapy Review the QA process and learn about the development of clinical workflows for these imaging options at different institutions.

  4. Speedup of optimization-based approach to local backlight dimming of HDR displays

    DEFF Research Database (Denmark)

    Burini, Nino; Nadernejad, Ehsan; Korhonen, Jari

    2012-01-01

    Local backlight dimming in Liquid Crystal Displays (LCD) is a technique for reducing power consumption and simultaneously increasing contrast ratio to provide a High Dynamic Range (HDR) image reproduction. Several backlight dimming algorithms exist with focus on reducing power consumption, while...

  5. A Survey on the Acceptance and the Use of HDR Photography Among Croatian Photographers

    Directory of Open Access Journals (Sweden)

    Maja Strgar Kurecic

    2013-04-01

    Full Text Available The emerging field of high dynamic range (HDR imaging is directly linked to diverse existing disciplines such as radiometry, photometry, colorimetry and colour appearance - each dealing with specific aspects of light and its perception by humans. Although the idea is not new, it has not been widely used until just a few years ago when digital cameras gained popularity and the computers processing power increased significantly. Now this photographic technique is widely spread and used, but even more often – misused. A research was conducted by means of a questionnaire in order to get some actual information about how Croatian photographers see the HDR photography and how they employ it. The results of the survey proved that indeed a great interest exists in the technique, but that many photographers are scared away from the HDR photography because of the misconception that the artificial look is an unavoidable side effect of the HDR processing. The fact is, however, that the final HDR image is a result of the tone mapping process and post-corrections and adjustments, entirely dependent on the photographer’s intent and vision, as well as his understanding of various adjustments available. The results of the questionnaire have also pointed out to other widely spread misconceptions which are discussed in this paper.

  6. TU-AB-201-07: Image Guided Endorectal HDR Brachytherapy Using a Compliant Balloon Applicator

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, G; Goodman, K [Memorial Sloan Kettering Cancer Center, New York, NY (United States)

    2015-06-15

    Purpose: High dose rate endorectal brachytherapy is an option to deliver a focal, high-dose radiotherapy to rectal tumors for patients undergoing non-operative management. We investigate a new multichannel, MR compatible applicator with a novel balloon-based design to provide improved treatment geometry. We report on the initial clinical experience using this applicator. Methods: Patients were enrolled on an IRB-approved, dose-escalation protocol evaluating the use of the anorectal (AR-1) applicator (Ancer Medical, Hialeah, FL), a multichannel applicator with two concentric balloons. The inner balloon supports 8 source lumens; the compliant outer balloon expands to separate the normal rectal wall and the source lumens, yet deforms around a firm, exophytic rectal mass, leading to dose escalation to tumor while sparing normal rectum. Under general anesthesia, gold fiducial markers were inserted above and below the tumor, and the AR applicator was placed in the rectum. MRI-based treatment plans were prepared to deliver 15 Gy in 3 weekly fractions to the target volume while sparing healthy rectal tissue, bladder, bowel and anal muscles. Prior to each treatment, CBCT/Fluoroscopy were used to place the applicator in the treatment position and confirm the treatment geometry using rigid registration of the CBCT and planning MRI. After registration of the applicator images, positioning was evaluated based on the match of the gold markers. Results: Highly conformal treatment plans were achieved. MR compatibility of the applicator enabled good tumor visualization. In spite of the non-rigid nature of the applicators and the fact that a new applicator was used at each treatment session, treatment geometry was reproducible to within 2.5 mm. Conclusions: This is the first report on using the AR applicator in patients. Highly conformal plans, confidence in MRI target delineation, in combination with reproducible treatment geometry provide encouraging feedback for continuation with

  7. Image-Guided High-Dose-Rate (HDR) Boost Localization Using MRI/MR Spectroscopy: A Correlation Study with Biopsy.

    Science.gov (United States)

    Vigneault, Eric; Mbodji, Khaly; Racine, Louis G; Chevrette, Eric; Lavallee, Marie C; Martin, André-Guy; Despres, Philippe; Beaulieu, Luc

    2016-09-21

    The purpose of this study is to compare the blind interpretations of magnetic resonance imaging (MRI) sequences, diffusion-weighted imaging (DWI), apparent diffusion coefficient (ADC), mapping, and magnetic resonance spectroscopy (MRS) of the prostate, in comparison to prostate biopsy to identify a valid dominant intraprostatic lesion (DIL) for dose escalation using high-dose rate brachytherapy. MRI/MRS were performed on 20 patients with intermediate risk adenocarcinoma of the prostate. T1W, T2W, DWI-ADC, and MRS sequences were performed at 1.5 T with pelvic and endorectal coils. An experienced radiologist rated the presence of cancer in each sextant by using a dichotomic approach, first on MR standard acquisitions (T1W and T2W), then on DWI-ADC mapping, and later on MRS images. Areas under the receiver's operating characteristic curve were calculated using a sextant as the unit of analysis. The transrectal ultrasonography-guided biopsy results were used as the reference standard. A table summarizing the MRI/MRS findings was made and compared to the corresponding area in the prostate biopsy report. A perfect match was defined to be the presence of cancer in the same sextant of the MRI/MRS exam and the prostate biopsy. The interpretation of the MRI/MRS exams per sextant was compared to the diagnostic biopsy report. MRI readings were compared with the biopsy as a surrogate for the complete pathology specimen of the prostate. A sensitivity (Sn) of 98.6% (95% confidence interval, 92.2% - 99.9%) and specificity (Sp) of 60.8% (46.1% - 74.2%) were found. The positive and negative predictive values (PPV, NPV) were 77.3% (67.1% - 85.5%) and 96.9% (83.8% - 99.9%), respectively. When MRS readings were compared with biopsy, we found a Sn of 96.4% (87.7% - 99.6%) and Sp of 54.8% (38.7% - 70.2%). The PPV and NPV were 74% (62.4% - 83.6%) and 92% (74% - 99%), respectively. DWI-ADC mapping results were also compared with biopsy. We found a Sn and Sp of 93.7% (84.5% - 98.2%) and 82

  8. SU-C-16A-01: In Vivo Source Position Verification in High Dose Rate (HDR) Prostate Brachytherapy Using a Flat Panel Imager: Initial Clinical Experience

    Energy Technology Data Exchange (ETDEWEB)

    Franich, R; Smith, R; Millar, J [RMIT University, Melbourne, Victoria (Australia); The Alfred Hospital, Melbourne, Victoria (Australia); Haworth, A [RMIT University, Melbourne, Victoria (Australia); Peter MacCallum Cancer Centre, Melbourne, Victoria (Australia); Taylor, M [RMIT University, Melbourne, Victoria (Australia); Australian Federal Police, Canberra, ACT (Australia); McDermott, L [RMIT University, Melbourne, Victoria (Australia)

    2014-06-15

    Purpose: We report our initial clinical experience with a novel position-sensitive source-tracking system based on a flat panel imager. The system has been trialled with 4 prostate HDR brachytherapy patients (8 treatment fractions) in this initial study. Methods: The flat panel imaging system was mounted under a customised carbon fibre couch top assembly (Figure 1). Three gold fiducial markers were implanted into the prostate of each patient at the time of catheter placement. X-ray dwell position markers were inserted into three catheters and a radiograph acquired to locate the implant relative to the imaging device. During treatment, as the HDR source dwells were delivered, images were acquired and processed to determine the position of the source in the patient. Source positions measured by the imaging device were compared to the treatment plan for verification of treatment delivery. Results: Measured dwell positions provided verification of relative dwell spacing within and between catheters, in the coronal plane. Measurements were typically within 2.0mm (0.2mm – 3.3mm, s.d. 0.8mm) of the planned positions over 60 dwells (Figure 2). Discrimination between larger dwell intervals and catheter differentiation were clear. This confirms important delivery attributes such as correct transfer tube connection, source step size, relative catheter positions and therefore overall correct plan selection and delivery. The fiducial markers, visible on the radiograph, provided verification of treatment delivery to the correct anatomical location. The absolute position of the dwells was determined by comparing the measured dwell positions with the x-ray markers from the radiograph, validating the programmed treatment indexer length. The total impact on procedure time was less than 5 minutes. Conclusion: The novel, noninvasive HDR brachytherapy treatment verification system was used clinically with minor impact on workflow. The system allows verification of correct treatment

  9. Optimizing Low Light Level Imaging Techniques and Sensor Design Parameters using CCD Digital Cameras for Potential NASA Earth Science Research aboard a Small Satellite or ISS Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This project made use of two computational photography techniques, high dynamic range (HDR) imagery formulation and bilateral filters to enable novel imaging...

  10. The conception and implementation of a local HDR fusion algorithm depending on contrast and luminosity parameters

    Science.gov (United States)

    Besrour, Amine; Abdelkefi, Fatma; Siala, Mohamed; Snoussi, Hichem

    2015-09-01

    Nowadays, the high dynamic range (HDR) imaging represents the subject of the most researches. The major problem lies in the implementation of the best algorithm to acquire the best video quality. In fact, the major constraint is to conceive an optimal fusion which must meet the rapid movement of video frames. The implemented merging algorithms were not quick enough to reconstitute the HDR video. In this paper, we detail each of the previous existing works before detailing our algorithm and presenting results from the acquired HDR images, tone mapped with various techniques. Our proposed algorithm guarantees a more enhanced and faster solution compared to the existing ones. In fact, it has the ability to calculate the saturation matrix related to the saturation rate of the neighboring pixels. The computed coefficients are affected respectively to each picture from the tested ones. This analysis provides faster and efficient results in terms of quality and brightness. The originality of our work remains on its processing method including the pixels saturation in the totality of the captured pictures and their combination in order to obtain the best pictures illustrating all the possible details. These parameters are computed for each zone depending on the contrast and the luminosity of the current pixel and its neighboring. The final HDR image's coefficients are calculated dynamically ensuring the best image quality equilibrating the brightness and contrast values and making the perfect final image.

  11. Realistic camera noise modeling with application to improved HDR synthesis

    Science.gov (United States)

    Goossens, Bart; Luong, Hiêp; Aelterman, Jan; Pižurica, Aleksandra; Philips, Wilfried

    2012-12-01

    Due to the ongoing miniaturization of digital camera sensors and the steady increase of the "number of megapixels", individual sensor elements of the camera become more sensitive to noise, even deteriorating the final image quality. To go around this problem, sophisticated processing algorithms in the devices, can help to maximally exploit the knowledge on the sensor characteristics (e.g., in terms of noise), and offer a better image reconstruction. Although a lot of research focuses on rather simplistic noise models, such as stationary additive white Gaussian noise, only limited attention has gone to more realistic digital camera noise models. In this article, we first present a digital camera noise model that takes several processing steps in the camera into account, such as sensor signal amplification, clipping, post-processing,.. We then apply this noise model to the reconstruction problem of high dynamic range (HDR) images from a small set of low dynamic range (LDR) exposures of a static scene. In literature, HDR reconstruction is mostly performed by computing a weighted average, in which the weights are directly related to the observer pixel intensities of the LDR image. In this work, we derive a Bayesian probabilistic formulation of a weighting function that is near-optimal in the MSE sense (or SNR sense) of the reconstructed HDR image, by assuming exponentially distributed irradiance values. We define the weighting function as the probability that the observed pixel intensity is approximately unbiased. The weighting function can be directly computed based on the noise model parameters, which gives rise to different symmetric and asymmetric shapes when electronic noise or photon noise is dominant. We also explain how to deal with the case that some of the noise model parameters are unknown and explain how the camera response function can be estimated using the presented noise model. Finally, experimental results are provided to support our findings.

  12. SU-F-T-29: The Important of Each Fraction Image-Guided Planning for Postoperative HDR-Brachytherapy in Endometrial Carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Piriyasang, D; Pattaranutaporn, P; Manokhoon, K [Ramathibodi Hospital, Rachatewi, Bangkok (Thailand)

    2016-06-15

    Purpose: Cylindrical applicators are often used for postoperative HDRbrachytherapy in endometrial carcinoma. It has been considered that dosimetric variation between fractions for this treatment is minimal and might not be necessary to perform treatment planning for every fractions. At our institute, it is traditional to perform treatment planning with CT simulation on the first fraction and uses this plan for the rest of treatment. This study was aim to evaluate the errors of critical structure doses between the fractions when simulation and planning were done for first fraction only. Methods: Treatment plans of 10 endometrial carcinoma patients who received postoperative HDR-brachytherapy and underwent CT-simulation for every HDR-fractions at our department were retrospectively reviewed. All of these patients were treated with cylindrical applicator and prescribed dose 15Gy in 3 fractions to 0.5cm from vaginal surface. The treatment plan from the first fraction was used to simulate in second and third CT-simulation. Radiation dose for critical structures in term of Dose-to-2cc (D2cc) were evaluated and compared between planning CT. Results: The D2cc for bladder and rectum were evaluated. For bladder, the mean error of D2cc estimation for second and third fractions was 7.6% (0.1–20.1%, SD=5.7). And the mean error for D2cc of rectum was 8.5% (0.1–29.4%, SD=8.5). Conclusion: The critical structure doses could be significant difference between fractions which may affects treatment outcomes or toxicities. From our data, image-guided brachytherapy at least with CT-Simulation should be done for every treatment fractions.

  13. Visual acuity-adaptive detail enhancement and shadow noise reduction for iCAM06-based HDR imaging

    Science.gov (United States)

    Lee, Geun-Young; Lee, Sung-Hak; Kwon, Hyuk-Ju; Sohng, Kyu-Ik

    2015-04-01

    An image appearance model is extremely useful for high-dynamic-range image (HDRI) rendering. However, the base-detail separation and the tone compression process for tonal control cause degradations in image quality. This study focuses on the de-saturation, reduced contrast, and noise problems in dark regions that occur through HDRI-rendering. First, we discuss de-saturation compensation using a bilateral filter that is based on the visual acuity characteristics of various illuminant levels. The edge stop function of the bilateral filter in iCAM06 is adaptively modified according to the illuminant information. Second, to reduce the magnified noise in the dark regions caused by tone mapping, the shadow regions are detected by an object's intensity and illuminant level, and then the noise of the detected regions is reduced using a luminance-adaptive coring function. Finally, we confirmed the enhanced color saturation, image contrast, and reduced noise in shadow regions through the application of the proposed methods.

  14. A method for verification of treatment delivery in HDR prostate brachytherapy using a flat panel detector for both imaging and source tracking

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Ryan L., E-mail: ryan.smith@wbrc.org.au; Millar, Jeremy L.; Franich, Rick D. [Alfred Health Radiation Oncology, The Alfred Hospital, Melbourne, VIC 3004, Australia and School of Science, RMIT University, Melbourne, VIC 3000 (Australia); Haworth, Annette [School of Science, RMIT University, Melbourne, VIC 3000, Australia and Physical Sciences, Peter MacCallum Cancer Centre, East Melbourne, VIC 3002 (Australia); Panettieri, Vanessa [Alfred Health Radiation Oncology, The Alfred Hospital, Melbourne, VIC 3004 (Australia)

    2016-05-15

    Purpose: Verification of high dose rate (HDR) brachytherapy treatment delivery is an important step, but is generally difficult to achieve. A technique is required to monitor the treatment as it is delivered, allowing comparison with the treatment plan and error detection. In this work, we demonstrate a method for monitoring the treatment as it is delivered and directly comparing the delivered treatment with the treatment plan in the clinical workspace. This treatment verification system is based on a flat panel detector (FPD) used for both pre-treatment imaging and source tracking. Methods: A phantom study was conducted to establish the resolution and precision of the system. A pretreatment radiograph of a phantom containing brachytherapy catheters is acquired and registration between the measurement and treatment planning system (TPS) is performed using implanted fiducial markers. The measured catheter paths immediately prior to treatment were then compared with the plan. During treatment delivery, the position of the {sup 192}Ir source is determined at each dwell position by measuring the exit radiation with the FPD and directly compared to the planned source dwell positions. Results: The registration between the two corresponding sets of fiducial markers in the TPS and radiograph yielded a registration error (residual) of 1.0 mm. The measured catheter paths agreed with the planned catheter paths on average to within 0.5 mm. The source positions measured with the FPD matched the planned source positions for all dwells on average within 0.6 mm (s.d. 0.3, min. 0.1, max. 1.4 mm). Conclusions: We have demonstrated a method for directly comparing the treatment plan with the delivered treatment that can be easily implemented in the clinical workspace. Pretreatment imaging was performed, enabling visualization of the implant before treatment delivery and identification of possible catheter displacement. Treatment delivery verification was performed by measuring the

  15. A method for verification of treatment delivery in HDR prostate brachytherapy using a flat panel detector for both imaging and source tracking.

    Science.gov (United States)

    Smith, Ryan L; Haworth, Annette; Panettieri, Vanessa; Millar, Jeremy L; Franich, Rick D

    2016-05-01

    Verification of high dose rate (HDR) brachytherapy treatment delivery is an important step, but is generally difficult to achieve. A technique is required to monitor the treatment as it is delivered, allowing comparison with the treatment plan and error detection. In this work, we demonstrate a method for monitoring the treatment as it is delivered and directly comparing the delivered treatment with the treatment plan in the clinical workspace. This treatment verification system is based on a flat panel detector (FPD) used for both pre-treatment imaging and source tracking. A phantom study was conducted to establish the resolution and precision of the system. A pretreatment radiograph of a phantom containing brachytherapy catheters is acquired and registration between the measurement and treatment planning system (TPS) is performed using implanted fiducial markers. The measured catheter paths immediately prior to treatment were then compared with the plan. During treatment delivery, the position of the (192)Ir source is determined at each dwell position by measuring the exit radiation with the FPD and directly compared to the planned source dwell positions. The registration between the two corresponding sets of fiducial markers in the TPS and radiograph yielded a registration error (residual) of 1.0 mm. The measured catheter paths agreed with the planned catheter paths on average to within 0.5 mm. The source positions measured with the FPD matched the planned source positions for all dwells on average within 0.6 mm (s.d. 0.3, min. 0.1, max. 1.4 mm). We have demonstrated a method for directly comparing the treatment plan with the delivered treatment that can be easily implemented in the clinical workspace. Pretreatment imaging was performed, enabling visualization of the implant before treatment delivery and identification of possible catheter displacement. Treatment delivery verification was performed by measuring the source position as each dwell was delivered

  16. Systematic Review of Focal Prostate Brachytherapy and the Future Implementation of Image-Guided Prostate HDR Brachytherapy Using MR-Ultrasound Fusion

    Directory of Open Access Journals (Sweden)

    M. Sean Peach

    2016-01-01

    Full Text Available Prostate cancer is the most common malignancy found in North American and European men and the second most common cause of cancer related death. Since the practice of PSA screening has become common the disease is most often found early and can have a long indolent course. Current definitive therapy treats the whole gland but has considerable long-term side effects. Focal therapies may be able to target the cancer while decreasing dose to organs at risk. Our objective was to determine if focal prostate brachytherapy could meet target objectives while permitting a decrease in dose to organs at risk in a way that would allow future salvage treatments. Further, we wanted to determine if focal treatment results in less toxicity. Utilizing the Medline repository, dosimetric papers comparing whole gland to partial gland brachytherapy and clinical papers that reported toxicity of focal brachytherapy were selected. A total of 9 dosimetric and 6 clinical papers met these inclusion criteria. Together, these manuscripts suggest that focal brachytherapy may be employed to decrease dose to organs at risk with decreased toxicity. Of current technology, image-guided HDR brachytherapy using MRI registered to transrectal ultrasound offers the flexibility and efficiency to achieve such focal treatments.

  17. HDR brachytherapy for superficial non-melanoma skin cancers.

    Science.gov (United States)

    Gauden, Ruth; Pracy, Martin; Avery, Anne-Marie; Hodgetts, Ian; Gauden, Stan

    2013-04-01

    Our initial experience using recommended high dose per fraction skin brachytherapy (BT) treatment schedules, resulted in poor cosmesis. This study aimed to assess in a prospective group of patients the use of Leipzig surface applicators for High Dose Rate (HDR) brachytherapy, for the treatment of small non-melanoma skin cancers (NMSC) using a protracted treatment schedule. Treatment was delivered by HDR brachytherapy with Leipzig applicators. 36 Gy, prescribed to between 3 to 4 mm, was given in daily 3 Gy fractions. Acute skin toxicity was evaluated weekly during irradiation using the Radiation Therapy Oncology Group criteria. Local response, late skin effects and cosmetic results were monitored at periodic intervals after treatment completion. From March 2002, 200 patients with 236 lesions were treated. Median follow-up was 66 months (range 25-121 months). A total of 162 lesions were macroscopic, while in 74 cases, BT was given after resection because of positive microscopic margins. There were 121 lesions that were basal cell carcinomas, and 115 were squamous cell carcinomas. Lesions were located on the head and neck (198), the extremities (26) and trunk (12). Local control was 232/236 (98%). Four patients required further surgery to treat recurrence. Grade 1 acute skin toxicity was detected in 168 treated lesions (71%) and grade 2 in 81 (34%). Cosmesis was good or excellent in 208 cases (88%). Late skin hypopigmentation changes were observed in 13 cases (5.5%). Delivering 36 Gy over 2 weeks to superficial NMSC using HDR brachytherapy is well tolerated and provides a high local control rate without significant toxicity. © 2012 The Authors. Journal of Medical Imaging and Radiation Oncology © 2012 The Royal Australian and New Zealand College of Radiologists.

  18. Single-layer HDR video coding with SDR backward compatibility

    Science.gov (United States)

    Lasserre, S.; François, E.; Le Léannec, F.; Touzé, D.

    2016-09-01

    The migration from High Definition (HD) TV to Ultra High Definition (UHD) is already underway. In addition to an increase of picture spatial resolution, UHD will bring more color and higher contrast by introducing Wide Color Gamut (WCG) and High Dynamic Range (HDR) video. As both Standard Dynamic Range (SDR) and HDR devices will coexist in the ecosystem, the transition from Standard Dynamic Range (SDR) to HDR will require distribution solutions supporting some level of backward compatibility. This paper presents a new HDR content distribution scheme, named SL-HDR1, using a single layer codec design and providing SDR compatibility. The solution is based on a pre-encoding HDR-to-SDR conversion, generating a backward compatible SDR video, with side dynamic metadata. The resulting SDR video is then compressed, distributed and decoded using standard-compliant decoders (e.g. HEVC Main 10 compliant). The decoded SDR video can be directly rendered on SDR displays without adaptation. Dynamic metadata of limited size are generated by the pre-processing and used to reconstruct the HDR signal from the decoded SDR video, using a post-processing that is the functional inverse of the pre-processing. Both HDR quality and artistic intent are preserved. Pre- and post-processing are applied independently per picture, do not involve any inter-pixel dependency, and are codec agnostic. Compression performance, and SDR quality are shown to be solidly improved compared to the non-backward and backward-compatible approaches, respectively using the Perceptual Quantization (PQ) and Hybrid Log Gamma (HLG) Opto-Electronic Transfer Functions (OETF).

  19. Image-Guided High-Dose-Rate (HDR) Boost Localization Using MRI/MR Spectroscopy: A Correlation Study with Biopsy

    OpenAIRE

    Vigneault, Eric; Mbodji, Khaly; Racine, Louis G; Chevrette, Eric; Lavallee, Marie C; Martin, Andr?-Guy; Despres, Philippe; Beaulieu, Luc

    2016-01-01

    Purpose: The purpose of this study is to compare the blind interpretations of magnetic resonance imaging (MRI) sequences, diffusion-weighted imaging (DWI), apparent diffusion coefficient (ADC), mapping, and magnetic resonance spectroscopy (MRS) of the prostate, in comparison to prostate biopsy to identify a valid dominant intraprostatic lesion (DIL) for dose escalation using high-dose rate brachytherapy. Methods: MRI/MRS were performed on 20 patients with intermediate risk adenocarcinoma of t...

  20. Enhanced dynamic range x-ray imaging.

    Science.gov (United States)

    Haidekker, Mark A; Morrison, Logan Dain-Kelley; Sharma, Ajay; Burke, Emily

    2017-03-01

    X-ray images can suffer from excess contrast. Often, image exposure is chosen to visually optimize the region of interest, but at the expense of over- and underexposed regions elsewhere in the image. When image values are interpreted quantitatively as projected absorption, both over- and underexposure leads to the loss of quantitative information. We propose to combine multiple exposures into a composite that uses only pixels from those exposures in which they are neither under- nor overexposed. The composite image is created in analogy to visible-light high dynamic range photography. We present the mathematical framework for the recovery of absorbance from such composite images and demonstrate the method with biological and non-biological samples. We also show with an aluminum step-wedge that accurate recovery of step thickness from the absorbance values is possible, thereby highlighting the quantitative nature of the presented method. Due to the higher amount of detail encoded in an enhanced dynamic range x-ray image, we expect that the number of retaken images can be reduced, and patient exposure overall reduced. We also envision that the method can improve dual energy absorptiometry and even computed tomography by reducing the number of low-exposure ("photon-starved") projections. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. High-dynamic-range microscope imaging based on exposure bracketing in full-field optical coherence tomography.

    Science.gov (United States)

    Leong-Hoi, Audrey; Montgomery, Paul C; Serio, Bruno; Twardowski, Patrice; Uhring, Wilfried

    2016-04-01

    By applying the proposed high-dynamic-range (HDR) technique based on exposure bracketing, we demonstrate a meaningful reduction in the spatial noise in image frames acquired with a CCD camera so as to improve the fringe contrast in full-field optical coherence tomography (FF-OCT). This new signal processing method thus allows improved probing within transparent or semitransparent samples. The proposed method is demonstrated on 3 μm thick transparent polymer films of Mylar, which, due to their transparency, produce low contrast fringe patterns in white-light interference microscopy. High-resolution tomographic analysis is performed using the technique. After performing appropriate signal processing, resulting XZ sections are observed. Submicrometer-sized defects can be lost in the noise that is present in the CCD images. With the proposed method, we show that by increasing the signal-to-noise ratio of the images, submicrometer-sized defect structures can thus be detected.

  2. Evaluation of High Dynamic Range Photography as a Luminance Mapping Technique

    Energy Technology Data Exchange (ETDEWEB)

    Inanici, Mehlika; Galvin, Jim

    2004-12-30

    The potential, limitations, and applicability of the High Dynamic Range (HDR) photography technique is evaluated as a luminance mapping tool. Multiple exposure photographs of static scenes are taken with a Nikon 5400 digital camera to capture the wide luminance variation within the scenes. The camera response function is computationally derived using the Photosphere software, and is used to fuse the multiple photographs into HDR images. The vignetting effect and point spread function of the camera and lens system is determined. Laboratory and field studies have shown that the pixel values in the HDR photographs can correspond to the physical quantity of luminance with reasonable precision and repeatability.

  3. Introduction to sensors for ranging and imaging

    CERN Document Server

    Brooker, Graham

    2009-01-01

    ""This comprehensive text-reference provides a solid background in active sensing technology. It is concerned with active sensing, starting with the basics of time-of-flight sensors (operational principles, components), and going through the derivation of the radar range equation and the detection of echo signals, both fundamental to the understanding of radar, sonar and lidar imaging. Several chapters cover signal propagation of both electromagnetic and acoustic energy, target characteristics, stealth, and clutter. The remainder of the book introduces the range measurement process, active ima

  4. High Resolution, Range/Range-Rate Imager Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Visidyne proposes to develop a design for a small, lightweight, high resolution, in x, y, and z Doppler imager to assist in the guidance, navigation and control...

  5. Realization of High Dynamic Range Imaging in the GLORIA Network and Its Effect on Astronomical Measurement

    Directory of Open Access Journals (Sweden)

    Stanislav Vítek

    2016-01-01

    Full Text Available Citizen science project GLORIA (GLObal Robotic-telescopes Intelligent Array is a first free- and open-access network of robotic telescopes in the world. It provides a web-based environment where users can do research in astronomy by observing with robotic telescopes and/or by analyzing data that other users have acquired with GLORIA or from other free-access databases. Network of 17 telescopes allows users to control selected telescopes in real time or schedule any more demanding observation. This paper deals with new opportunity that GLORIA project provides to teachers and students of various levels of education. At the moment, there are prepared educational materials related to events like Sun eclipse (measuring local atmosphere changes, Aurora Borealis (calculation of Northern Lights height, or transit of Venus (measurement of the Earth-Sun distance. Student should be able to learn principles of CCD imaging, spectral analysis, basic calibration like dark frames subtraction, or advanced methods of noise suppression. Every user of the network can design his own experiment. We propose advanced experiment aimed at obtaining astronomical image data with high dynamic range. We also introduce methods of objective image quality evaluation in order to discover how HDR methods are affecting astronomical measurements.

  6. Sampling Number Effects in 2D and Range Imaging of Range-gated Acquisition

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Seong-Ouk; Park, Seung-Kyu; Baik, Sung-Hoon; Cho, Jai-Wan; Jeong, Kyung-Min [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    In this paper, we analyzed the number effects of sampling images for making a 2D image and a range image from acquired RGI images. We analyzed the number effects of RGI images for making a 2D image and a range image using a RGI vision system. As the results, 2D image quality was not much depended on the number of sampling images but on how much well extract efficient RGI images. But, the number of RGI images was important for making a range image because range image quality was proportional to the number of RGI images. Image acquiring in a monitoring area of nuclear industry is an important function for safety inspection and preparing appropriate control plans. To overcome the non-visualization problem caused by airborne obstacle particles, vision systems should have extra-functions, such as active illumination lightening through disturbance airborne particles. One of these powerful active vision systems is a range-gated imaging system. The vision system based on the range-gated imaging system can acquire image data from raining or smoking environments. Range-gated imaging (RGI) is a direct active visualization technique using a highly sensitive image sensor and a high intensity illuminant. Currently, the range-gated imaging technique providing 2D and 3D images is one of emerging active vision technologies. The range-gated imaging system gets vision information by summing time sliced vision images. In the RGI system, a high intensity illuminant illuminates for ultra-short time and a highly sensitive image sensor is gated by ultra-short exposure time to only get the illumination light. Here, the illuminant illuminates objects by flashing strong light through airborne disturbance particles. Thus, in contrast to passive conventional vision systems, the RGI active vision technology robust for low-visibility environments.

  7. Characteristics of different frequency ranges in scanning electron microscope images

    Energy Technology Data Exchange (ETDEWEB)

    Sim, K. S., E-mail: kssim@mmu.edu.my; Nia, M. E.; Tan, T. L.; Tso, C. P.; Ee, C. S. [Faculty of Engineering and Technology, Multimedia University, 75450 Melaka (Malaysia)

    2015-07-22

    We demonstrate a new approach to characterize the frequency range in general scanning electron microscope (SEM) images. First, pure frequency images are generated from low frequency to high frequency, and then, the magnification of each type of frequency image is implemented. By comparing the edge percentage of the SEM image to the self-generated frequency images, we can define the frequency ranges of the SEM images. Characterization of frequency ranges of SEM images benefits further processing and analysis of those SEM images, such as in noise filtering and contrast enhancement.

  8. ISAR imaging using the instantaneous range instantaneous Doppler method

    CSIR Research Space (South Africa)

    Wazna, TM

    2015-10-01

    Full Text Available In Inverse Synthetic Aperture Radar (ISAR) imaging, the Range Instantaneous Doppler (RID) method is used to compensate for the nonuniform rotational motion of the target that degrades the Doppler resolution of the ISAR image. The Instantaneous Range...

  9. Gold marker displacement due to needle insertion during HDR-brachytherapy for treatment of prostate cancer: A prospective cone beam computed tomography and kilovoltage on-board imaging (kV-OBI study

    Directory of Open Access Journals (Sweden)

    Herrmann Markus KA

    2012-02-01

    Full Text Available Abstract Purpose To evaluate gold marker displacement due to needle insertion during HDR-brachytherapy for therapy of prostate cancer. Patients and methods 18 patients entered into this prospective evaluation. Three gold markers were implanted into the prostate during the first HDR-brachytherapy procedure after the irradiation was administered. Three days after marker implantation all patients had a CT-scan for planning purpose of the percutaneous irradiation. Marker localization was defined on the digitally-reconstructed-radiographs (DRR for daily (VMAT technique or weekly (IMRT set-up error correction. Percutaneous therapy started one week after first HDR-brachytherapy. After the second HDR-brachytherapy, two weeks after first HDR-brachtherapy, a cone-beam CT-scan was done to evaluate marker displacement due to needle insertion. In case of marker displacement, the actual positions of the gold markers were adjusted on the DRR. Results The value of the gold marker displacement due to the second HDR-brachytherapy was analyzed in all patients and for each gold marker by comparison of the marker positions in the prostate after soft tissue registration of the prostate of the CT-scans prior the first and second HDR-brachytherapy. The maximum deviation was 5 mm, 7 mm and 12 mm for the anterior-posterior, lateral and superior-inferior direction. At least one marker in each patient showed a significant displacement and therefore new marker positions were adjusted on the DRRs for the ongoing percutaneous therapy. Conclusions Needle insertion in the prostate due to HDR-brachytherapy can lead to gold marker displacements. Therefore, it is necessary to verify the actual position of markers after the second HDR-brachytherapy. In case of significant deviations, a new DRR with the adjusted marker positions should be generated for precise positioning during the ongoing percutaneous irradiation.

  10. The history of HDR research and development

    Energy Technology Data Exchange (ETDEWEB)

    Duchane, D.

    1998-12-31

    An energy source rivaling the sun exists in the form of the heat emanating from the interior of the earth. Although limited quantities of this geothermal energy are produced today by bringing natural hot fluids to the surface, most of the earth`s heat is trapped in hot dry rock (HDR). The application of hydraulic fracturing technology to tap this vast HDR resource was pioneered by Los Alamos National Laboratory beginning in 1970. Since that time, engineered geothermal reservoirs have been constructed and operated at numerous locations around the world. Major work at the US HDR facility at Fenton Hill, NM, and at the British HDR site in Cornwall, UK, has been completed, but advanced HDR field work continues at two sites on the island of Honshu in Japan and at Soultz in northeastern France. In addition, plans are currently being completed for the construction of an HDR system on the continent of Australia. Over the past three decades the worldwide research and development effort has taken HDR from its early conceptual stage to its present state as a demonstrated technology that is on the verge of becoming commercially feasible. Extended flow tests in the United States, Japan, and Europe have proven that sustained operation of HDR reservoirs is possible. In support of these field tests, an international body of scientists and engineers have pursued a variety of innovative approaches for assessing HDR resources, constructing and characterizing engineered geothermal reservoirs, and operating HDR systems. Taken together, these developments form a strong base upon which to build the practical HDR systems that will provide clean energy for the world in the 21st century.

  11. Scannerless laser range imaging using loss modulation

    Energy Technology Data Exchange (ETDEWEB)

    Sandusky, John V [Albuquerque, NM

    2011-08-09

    A scannerless 3-D imaging apparatus is disclosed which utilizes an amplitude modulated cw light source to illuminate a field of view containing a target of interest. Backscattered light from the target is passed through one or more loss modulators which are modulated at the same frequency as the light source, but with a phase delay .delta. which can be fixed or variable. The backscattered light is demodulated by the loss modulator and detected with a CCD, CMOS or focal plane array (FPA) detector to construct a 3-D image of the target. The scannerless 3-D imaging apparatus, which can operate in the eye-safe wavelength region 1.4-1.7 .mu.m and which can be constructed as a flash LADAR, has applications for vehicle collision avoidance, autonomous rendezvous and docking, robotic vision, industrial inspection and measurement, 3-D cameras, and facial recognition.

  12. High Dynamic Range Digital Imaging of Spacecraft

    Science.gov (United States)

    Karr, Brian A.; Chalmers, Alan; Debattista, Kurt

    2014-01-01

    The ability to capture engineering imagery with a wide degree of dynamic range during rocket launches is critical for post launch processing and analysis [USC03, NNC86]. Rocket launches often present an extreme range of lightness, particularly during night launches. Night launches present a two-fold problem: capturing detail of the vehicle and scene that is masked by darkness, while also capturing detail in the engine plume.

  13. 3D imaging without range information

    Science.gov (United States)

    Rogers, J. D.; Myatt, D. R.

    2010-04-01

    Three-dimensional (3D) imaging technologies have considerable potential for aiding military operations in areas such as reconnaissance, mission planning and situational awareness through improved visualisation and user-interaction. This paper describes the development of fast 3D imaging capabilities from low-cost, passive sensors. The two systems discussed here are capable of passive depth perception and recovering 3D structure from a single electro-optic sensor attached to an aerial vehicle that is, for example, circling a target. Based on this example, the proposed method has been shown to produce high quality results when positional data of the sensor is known, and also in the more challenging case when the sensor geometry must be estimated from the input imagery alone. The methods described exploit prior knowledge concerning the type of sensor that is used to produce a more robust output.

  14. Dosimetry evaluation of SAVI-based HDR brachytherapy for partial breast irradiation

    Directory of Open Access Journals (Sweden)

    Manoharan Sivasubramanian

    2010-01-01

    Full Text Available Accelerated partial breast irradiation (APBI with high dose rate (HDR brachytherapy offers an excellent compact course of radiation due to its limited number of fractions for early-stage carcinoma of breast. One of the recent devices is SAVI (strut-adjusted volume implant, which has 6, 8 or 10 peripheral source channels with one center channel. Each channel can be differentially loaded. This paper focuses on the treatment planning, dosimetry and quality assurance aspects of HDR brachytherapy implant with GammaMed Plus HDR afterloader unit. The accelerated PBI balloon devices normally inflate above 35 cc range, and hence these balloon type devices cannot be accommodated in small lumpectomy cavity sizes. CT images were obtained and 3-D dosimetric plans were done with Brachyvision planning system. The 3-D treatment planning and dosimetric data were evaluated with planning target volume (PTV_eval V90, V95, V150, V200 skin dose and minimum distance to skin. With the use of the SAVI 6-1 mini device, we were able to accomplish an excellent coverage - V90, V95, V150 and V200 to 98%, 95%, 37 cc (<50 cc volume and 16 cc (<20 cc volume, respectively. Maximum skin dose was between 73% and 90%, much below the prescribed dose of 34 Gy. The minimum skin distance achieved was 5 to 11 mm. The volume that received 50% of the prescribed radiation dose was found to be lower with SAVI. The multi-channel SAVI-based implants reduced the maximum skin dose to markedly lower levels as compared to other modalities, simultaneously achieving best dose coverage to target volume. Differential-source dwell-loading allows modulation of the radiation dose distribution in symmetric or asymmetric opening of the catheter shapes and is also advantageous in cavities close to chest wall.

  15. Capability of Ophthalmology Residents to Detect Glaucoma Using High-Dynamic-Range Concept versus Color Optic Disc Photography.

    Science.gov (United States)

    Ittarat, Mantapond; Itthipanichpong, Rath; Manassakorn, Anita; Tantisevi, Visanee; Chansangpetch, Sunee; Rojanapongpun, Prin

    2017-01-01

    Assessment of color disc photograph (C-DP) is affected by image quality, which decreases the ability to detect glaucoma. High-dynamic-range (HDR) imaging provides a greater range of luminosity. Therefore, the objective of this study was to evaluate the capability of ophthalmology residents to detect glaucoma using HDR-concept disc photography (HDR-DP) compared to C-DP. Cross-sectional study. Twenty subjects were classified by 3 glaucoma specialists as either glaucoma, glaucoma suspect, or control. All C-DPs were converted to HDR-DPs and randomly presented and assessed by 10 first-year ophthalmology residents. Sensitivity and specificity of glaucoma detection were compared. The mean ± SD of averaged retinal nerve fiber layer (RNFL) thickness was 74.0 ± 6.1 μm, 100.2 ± 9.6 μm, and 105.8 ± 17.2 μm for glaucoma, glaucoma suspect, and controls, respectively. The diagnostic sensitivity of HDR-DP was higher than that of C-DP (87% versus 68%, mean difference: 19.0, 95% CI: 4.91 to 33.1; p = 0.014). Regarding diagnostic specificity, HDR-DP and C-DP yielded 46% and 75% (mean difference: 29.0, 95% CI: 13.4 to 44.6; p = 0.002). HDR-DP statistically increased diagnostic sensitivity but not specificity. HDR-DP may be a screening tool for nonexpert ophthalmologists.

  16. Visual Control of Robots Using Range Images

    Directory of Open Access Journals (Sweden)

    Fernando Torres

    2010-08-01

    Full Text Available In the last years, 3D-vision systems based on the time-of-flight (ToF principle have gained more importance in order to obtain 3D information from the workspace. In this paper, an analysis of the use of 3D ToF cameras to guide a robot arm is performed. To do so, an adaptive method to simultaneous visual servo control and camera calibration is presented. Using this method a robot arm is guided by using range information obtained from a ToF camera. Furthermore, the self-calibration method obtains the adequate integration time to be used by the range camera in order to precisely determine the depth information.

  17. Building accurate geometric models from abundant range imaging information

    Science.gov (United States)

    Diegert, Carl F.; Sackos, John T.; Nellums, Robert O.

    1997-08-01

    We define two simple metrics for accuracy of models built from range imaging information. We apply the metric to a model built from a recent range image taken at the laser radar Development and Evaluation Facility, Eglin AFB, using a scannerless range imager (SRI) from Sandia National Laboratories. We also present graphical displays of the residual information produced as a byproduct of this measurement, and discuss mechanisms that these data suggest for further improvement in the performance of this already impressive SRI.

  18. Transition from LDR to HDR brachytherapy for cervical cancer: Evaluation of tumor control, survival, and toxicity.

    Science.gov (United States)

    Romano, K D; Pugh, K J; Trifiletti, D M; Libby, B; Showalter, T N

    In 2012, our institution transitioned from low-dose-rate (LDR) brachytherapy to high dose-rate (HDR) brachytherapy. We report clinical outcomes after brachytherapy for cervical cancer at our institution over a continuous 10-year period. From 2004 to 2014, 258 women (184 LDR and 74 HDR) were treated with tandem and ovoid brachytherapy in the multidisciplinary management of International Federation of Gynecology and Obstetrics Stages IA-IVB cervical cancer. Clinical and treatment-related prognostic factors including age, stage, smoking status, relevant doses, and toxicity data were recorded. Median followup for the LDR and HDR groups was 46 months and 12 months, respectively. The majority of patients (92%) received external beam radiotherapy as well as concurrent chemotherapy (83%) before the start of brachytherapy. For all stages, the 1-year local control and overall survival (OS) rates were comparable between the LDR and HDR groups (87% vs. 81%, p = 0.12; and 75% vs. 85%, p = 0.16), respectively. Factors associated with OS on multivariate analysis include age, stage, and nodal involvement. On multivariate analysis, severe toxicity (acute or chronic) was higher with HDR than LDR (24% vs. 10%, p = 0.04). Additional prognostic factors associated with increased severe toxicity include former/current smokers and total dose to lymph nodes. This comparative retrospective analysis of a large cohort of women treated with brachytherapy demonstrates no significant difference in OS or local control between the LDR and HDR. Acute and chronic toxicity increased shortly after the implementation of HDR, highlighting the importance of continued refinement of HDR methods, including integrating advanced imaging. Copyright © 2016 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  19. High Dynamic Range Video

    CERN Document Server

    Myszkowski, Karol

    2008-01-01

    This book presents a complete pipeline forHDR image and video processing fromacquisition, through compression and quality evaluation, to display. At the HDR image and video acquisition stage specialized HDR sensors or multi-exposure techniques suitable for traditional cameras are discussed. Then, we present a practical solution for pixel values calibration in terms of photometric or radiometric quantities, which are required in some technically oriented applications. Also, we cover the problem of efficient image and video compression and encoding either for storage or transmission purposes, in

  20. Target Image Matching Algorithm Based on Binocular CCD Ranging

    Directory of Open Access Journals (Sweden)

    Dongming Li

    2014-01-01

    Full Text Available This paper proposed target image in a subpixel level matching algorithm for binocular CCD ranging, which is based on the principle of binocular CCD ranging. In the paper, firstly, we introduced the ranging principle of the binocular ranging system and deduced a binocular parallax formula. Secondly, we deduced the algorithm which was named improved cross-correlation matching algorithm and cubic surface fitting algorithm for target images matched, and it could achieve a subpixel level matching for binocular CCD ranging images. Lastly, through experiment we have analyzed and verified the actual CCD ranging images, then analyzed the errors of the experimental results and corrected the formula of calculating system errors. Experimental results showed that the actual measurement accuracy of a target within 3 km was higher than 0.52%, which meet the accuracy requirements of the high precision binocular ranging.

  1. Real-time extended dynamic range imaging in shearography.

    Science.gov (United States)

    Groves, Roger M; Pedrini, Giancarlo; Osten, Wolfgang

    2008-10-20

    Extended dynamic range (EDR) imaging is a postprocessing technique commonly associated with photography. Multiple images of a scene are recorded by the camera using different shutter settings and are merged into a single higher dynamic range image. Speckle interferometry and holography techniques require a well-modulated intensity signal to extract the phase information, and of these techniques shearography is most sensitive to different object surface reflectivities as it uses self-referencing from a sheared image. In this paper the authors demonstrate real-time EDR imaging in shearography and present experimental results from a difficult surface reflectivity sample: a wooden panel painting containing gold and dark earth color paint.

  2. Color appearance and color rendering of HDR scenes: an experiment

    Science.gov (United States)

    Parraman, Carinna; Rizzi, Alessandro; McCann, John J.

    2009-01-01

    In order to gain a deeper understanding of the appearance of coloured objects in a three-dimensional scene, the research introduces a multidisciplinary experimental approach. The experiment employed two identical 3-D Mondrians, which were viewed and compared side by side. Each scene was subjected to different lighting conditions. First, we used an illumination cube to diffuse the light and illuminate all the objects from each direction. This produced a low-dynamicrange (LDR) image of the 3-D Mondrian scene. Second, in order to make a high-dynamic range (HDR) image of the same objects, we used a directional 150W spotlight and an array of WLEDs assembled in a flashlight. The scenes were significant as each contained exactly the same three-dimensional painted colour blocks that were arranged in the same position in the still life. The blocks comprised 6 hue colours and 5 tones from white to black. Participants from the CREATE project were asked to consider the change in the appearance of a selection of colours according to lightness, hue, and chroma, and to rate how the change in illumination affected appearance. We measured the light coming to the eye from still-life surfaces with a colorimeter (Yxy). We captured the scene radiance using multiple exposures with a number of different cameras. We have begun a programme of digital image processing of these scene capture methods. This multi-disciplinary programme continues until 2010, so this paper is an interim report on the initial phases and a description of the ongoing project.

  3. Cosmetic effect in patients with early breast cancer treated with breast conserving therapy (BCT) and with HDR brachytherapy (HDR-BT) “boost”

    Science.gov (United States)

    Łyczek, Jarosław; Kawczyn´ska, Maria; Gruszczyn´ska, Ewelina

    2009-01-01

    Purpose The estimation of cosmetic effect in 93 patients with early breast cancer treated with breast conserving surgery (BCS) followed by combined radiotherapy, including HDR brachytherapy (HDR-BT) boost. Material and methods After BCS (tumorectomy or quadrantectomy) external beam radiation therapy (EBRT) was used in total dose of 50 Gy for the whole breast. Tumor bed was localized basing on clinical and mammographic preoperative examinations and histopathology evaluation. 10 Gy in one fraction was applied to all patients using HDR-BT. Steel interstitial needles stabilized by plastic templates were used. 192-Ir with 10 Ci nominal activity and HDR-GammaMed 12i unit (Mick Radio-Nuclear Instruments, Inc., Mt. Vernon, NY) and ABACUS software were used. 31 patients received additional chemotherapy. Cosmetic effect was evaluated in 36 month after the end of brachytherapy treatment basing on modified EORTC scale. For statistical analysis the rang of correlation test, contingent test, linear regression test and ProbRough rulet induction test were used. Results and Conclusions HDR-BT tolerance was good in most of the cases. Excellent and very good cosmetic effect was observed in 79 patients (85%). Statistically important correlations between following examined prognostic factors and cosmetics outcome were observed: clinical and mammographic tumor estimation, method of breast conserving surgery, type of skin incision, number of interstitial applicators, irradiated reference volume (PTV) and type of optimization method. No correlations with cosmetics effect were found in factors such as: age of patients, location of tumor or additional therapy. PMID:27795716

  4. SEGMENTATION AND QUALITY ANALYSIS OF LONG RANGE CAPTURED IRIS IMAGE

    Directory of Open Access Journals (Sweden)

    Anand Deshpande

    2016-05-01

    Full Text Available The iris segmentation plays a major role in an iris recognition system to increase the performance of the system. This paper proposes a novel method for segmentation of iris images to extract the iris part of long range captured eye image and an approach to select best iris frame from the iris polar image sequences by analyzing the quality of iris polar images. The quality of iris image is determined by the frequency components present in the iris polar images. The experiments are carried out on CASIA-long range captured iris image sequences. The proposed segmentation method is compared with Hough transform based segmentation and it has been determined that the proposed method gives higher accuracy for segmentation than Hough transform.

  5. High Brightness HDR Projection Using Dynamic Freeform Lensing

    KAUST Repository

    Damberg, Gerwin

    2016-05-03

    Cinema projectors need to compete with home theater displays in terms of image quality. High frame rate and spatial resolution as well as stereoscopic 3D are common features today, but even the most advanced cinema projectors lack in-scene contrast and, more important, high peak luminance, both of which are essential perceptual attributes of images appearing realistic. At the same time, HDR image statistics suggest that the average image intensity in a controlled ambient viewing environment such as the cinema can be as low as 1% for cinematic HDR content and not often higher than 18%, middle gray in photography. Traditional projection systems form images and colors by blocking the source light from a lamp, therefore attenuating between 99% and 82% of light, on average. This inefficient use of light poses significant challenges for achieving higher peak brightness levels. In this work, we propose a new projector architecture built around commercially available components, in which light can be steered to form images. The gain in system efficiency significantly reduces the total cost of ownership of a projector (fewer components and lower operating cost), and at the same time increases peak luminance and improves black level beyond what is practically achievable with incumbent projector technologies. At the heart of this computational display technology is a new projector hardware design using phase modulation in combination with a new optimization algorithm that is capable of on-the-fly computation of freeform lens surfaces. © 2016 ACM.

  6. Prostate CT segmentation method based on nonrigid registration in ultrasound-guided CT-based HDR prostate brachytherapy

    Science.gov (United States)

    Yang, Xiaofeng; Rossi, Peter; Ogunleye, Tomi; Marcus, David M.; Jani, Ashesh B.; Mao, Hui; Curran, Walter J.; Liu, Tian

    2014-01-01

    Purpose: The technological advances in real-time ultrasound image guidance for high-dose-rate (HDR) prostate brachytherapy have placed this treatment modality at the forefront of innovation in cancer radiotherapy. Prostate HDR treatment often involves placing the HDR catheters (needles) into the prostate gland under the transrectal ultrasound (TRUS) guidance, then generating a radiation treatment plan based on CT prostate images, and subsequently delivering high dose of radiation through these catheters. The main challenge for this HDR procedure is to accurately segment the prostate volume in the CT images for the radiation treatment planning. In this study, the authors propose a novel approach that integrates the prostate volume from 3D TRUS images into the treatment planning CT images to provide an accurate prostate delineation for prostate HDR treatment. Methods: The authors’ approach requires acquisition of 3D TRUS prostate images in the operating room right after the HDR catheters are inserted, which takes 1–3 min. These TRUS images are used to create prostate contours. The HDR catheters are reconstructed from the intraoperative TRUS and postoperative CT images, and subsequently used as landmarks for the TRUS–CT image fusion. After TRUS–CT fusion, the TRUS-based prostate volume is deformed to the CT images for treatment planning. This method was first validated with a prostate-phantom study. In addition, a pilot study of ten patients undergoing HDR prostate brachytherapy was conducted to test its clinical feasibility. The accuracy of their approach was assessed through the locations of three implanted fiducial (gold) markers, as well as T2-weighted MR prostate images of patients. Results: For the phantom study, the target registration error (TRE) of gold-markers was 0.41 ± 0.11 mm. For the ten patients, the TRE of gold markers was 1.18 ± 0.26 mm; the prostate volume difference between the authors’ approach and the MRI-based volume was 7.28% ± 0

  7. Range image registration using a photometric metric under unknown lighting.

    Science.gov (United States)

    Thomas, Diego; Sugimoto, Akihiro

    2013-09-01

    Based on the spherical harmonics representation of image formation, we derive a new photometric metric for evaluating the correctness of a given rigid transformation aligning two overlapping range images captured under unknown, distant, and general illumination. We estimate the surrounding illumination and albedo values of points of the two range images from the point correspondences induced by the input transformation. We then synthesize the color of both range images using albedo values transferred using the point correspondences to compute the photometric reprojection error. This way allows us to accurately register two range images by finding the transformation that minimizes the photometric reprojection error. We also propose a practical method using the proposed photometric metric to register pairs of range images devoid of salient geometric features, captured under unknown lighting. Our method uses a hypothesize-and-test strategy to search for the transformation that minimizes our photometric metric. Transformation candidates are efficiently generated by employing the spherical representation of each range image. Experimental results using both synthetic and real data demonstrate the usefulness of the proposed metric.

  8. Scientific progress on the Fenton Hill HDR project since 1983

    Energy Technology Data Exchange (ETDEWEB)

    Brown, D.W.; Duchane, D.V.

    1998-02-01

    The modern HDR concept originated at the Los Alamos National Laboratory and was first demonstrated at Fenton Hill, NM. Experience gained during the development of the deeper HDR reservoir at Fenton Hill clearly showed that HDR reservoirs are formed by opening pre-existing, but sealed, multiply connected joint sets. Subsequent flow testing indicated that sustained operation of HDR systems under steady state conditions is feasible. The most significant remaining HDR issues are related to economics and locational flexibility. Additional field test sites are needed to advance the understanding of HDR technology so that the vast potential of this resource can be economically realized around the world.

  9. Simultaneous radiochemotherapy and endoluminal HDR brachytherapy in esophageal cancer; Simultane Radiochemotherapie mit intraluminaler HDR-Brachytherapie des Oesophaguskarzinoms

    Energy Technology Data Exchange (ETDEWEB)

    Patonay, P.; Naszaly, A.; Mayer, A. [Hauptstaedtisches Zentrum fuer Radioonkologie und Strahlentherapie, Budapest (Hungary)

    2007-02-15

    Purpose: to study efficacy and toxicity of radiochemotherapy in esophageal cancer including initial endoluminal high-dose-rate brachytherapy (HDR-BT). Patients and methods: between 01/1995 and 06/2005, 61 patients with esophageal cancer were treated preoperatively with definitive and palliative intent. Treatment started with intraluminal HDR-BT for recanalization of the esophagus (single fraction size of 8 Gy in 0.5 cm depth, three times, q7d) followed by external-beam radiation therapy (50 Gy total dose, 5 x 2 Gy/week, 25 fractions in 5 weeks). Chemotherapy was started simultaneously with external irradiation (three courses of cisplatin and 5-fluorouracil, q21d). Results: swallowing function improved in 55/61 patients (dysphagia classification according to the RTOG), and worsened in 6/61 patients, respectively. Median duration of symptomatic improvement was 11 months, median follow-up 12 months (range 3-68 months). Following simultaneous radiochemotherapy, tumor resectability was achieved in 7/25 patients of the neoadjuvant group, and the histological specimen showed complete remission in 6/7 patients. Conclusion: these results indicate a favorable effect of simultaneous radiochemotherapy starting with endoluminal HDR-after-loading-(AL-)BT in esophageal cancer. (orig.)

  10. : Light Steering Projection Systems and Attributes for HDR Displays

    KAUST Repository

    Damberg, Gerwin

    2017-06-02

    New light steering projectors in cinema form images by moving light away from dark regions into bright areas of an image. In these systems, the peak luminance of small features can far exceed full screen white luminance. In traditional projectors where light is filtered or blocked in order to give shades of gray (or colors), the peak luminance is fixed. The luminance of chromatic features benefit in the same way as white features, and chromatic image details can be reproduced at high brightness leading to a much wider overall color gamut coverage than previously possible. Projectors of this capability are desired by the creative community to aid in and enhance storytelling. Furthermore, reduced light source power requirements of light steering projectors provide additional economic and environmental benefits. While the dependency of peak luminance level on (bright) image feature size is new in the digital cinema space, display technologies with identical characteristics such as OLED, LED LCD and Plasma TVs are well established in the home. Similarly, direct view LED walls are popular in events, advertising and architectural markets. To enable consistent color reproduction across devices in today’s content production pipelines, models that describe modern projectors and display attributes need to evolve together with HDR standards and available metadata. This paper is a first step towards rethinking legacy display descriptors such as contrast, peak luminance and color primaries in light of new display technology. We first summarize recent progress in the field of light steering projectors in cinema and then, based on new projector and existing display characteristics propose the inclusion of two simple display attributes: Maximum Average Luminance and Peak (Color) Primary Luminance. We show that the proposed attributes allow a better prediction of content reproducibility on HDR displays. To validate this assertion, we test professional content on a commercial HDR

  11. Range image segmentation for tree detection in forest scans

    Directory of Open Access Journals (Sweden)

    A. Bienert

    2013-10-01

    Full Text Available To make a tree-wise analysis inside a forest stand, the trees have to be identified. An interactive segmentation is often labourintensive and time-consuming. Therefore, an automatic detection process will aspired using a range image. This paper presents a method for the segmentation of range images extracted from terrestrial laser scanner point clouds of forest stands. After range image generation the segmentation is carried out with a connectivity analysis using the differences of the range values as homogeneity criterion. Subsequently, the tree detection is performed interactively by analysing one horizontal image line. When passing objects with a specific width, the object indicates a potential tree. By using the edge points of a segmented pixel group the tree position and diameter is calculated. Results from one test site are presented to show the performance of the method.

  12. Range-Image Acquisition for Discriminated Objects in a Range-gated Robot Vision System

    Energy Technology Data Exchange (ETDEWEB)

    Park, Seung-Kyu; Ahn, Yong-Jin; Park, Nak-Kyu; Baik, Sung-Hoon; Choi, Young-Soo; Jeong, Kyung-Min [KAERI, Daejeon (Korea, Republic of)

    2015-05-15

    The imaging capability of a surveillance vision system from harsh low-visibility environments such as in fire and detonation areas is a key function to monitor the safety of the facilities. 2D and range image data acquired from low-visibility environment are important data to assess the safety and prepare appropriate countermeasures. Passive vision systems, such as conventional camera and binocular stereo vision systems usually cannot acquire image information when the reflected light is highly scattered and absorbed by airborne particles such as fog. In addition, the image resolution captured through low-density airborne particles is decreased because the image is blurred and dimmed by the scattering, emission and absorption. Active vision systems, such as structured light vision and projected stereo vision are usually more robust for harsh environment than passive vision systems. However, the performance is considerably decreased in proportion to the density of the particles. The RGI system provides 2D and range image data from several RGI images and it moreover provides clear images from low-visibility fog and smoke environment by using the sum of time-sliced images. Nowadays, the Range-gated (RG) imaging is an emerging technology in the field of surveillance for security applications, especially in the visualization of invisible night and fog environment. Although RGI viewing was discovered in the 1960's, this technology is, nowadays becoming more applicable by virtue of the rapid development of optical and sensor technologies. Especially, this system can be adopted in robot-vision system by virtue of its compact portable configuration. In contrast to passive vision systems, this technology enables operation even in harsh environments like fog and smoke. During the past decades, several applications of this technology have been applied in target recognition and in harsh environments, such as fog, underwater vision. Also, this technology has been

  13. Range imager performance comparison in homodyne and heterodyne operating modes

    Science.gov (United States)

    Conroy, Richard M.; Dorrington, Adrian A.; Künnemeyer, Rainer; Cree, Michael J.

    2009-01-01

    Range imaging cameras measure depth simultaneously for every pixel in a given field of view. In most implementations the basic operating principles are the same. A scene is illuminated with an intensity modulated light source and the reflected signal is sampled using a gain-modulated imager. Previously we presented a unique heterodyne range imaging system that employed a bulky and power hungry image intensifier as the high speed gain-modulation mechanism. In this paper we present a new range imager using an internally modulated image sensor that is designed to operate in heterodyne mode, but can also operate in homodyne mode. We discuss homodyne and heterodyne range imaging, and the merits of the various types of hardware used to implement these systems. Following this we describe in detail the hardware and firmware components of our new ranger. We experimentally compare the two operating modes and demonstrate that heterodyne operation is less sensitive to some of the limitations suffered in homodyne mode, resulting in better linearity and ranging precision characteristics. We conclude by showing various qualitative examples that demonstrate the system's three-dimensional measurement performance.

  14. POTENTIALS OF IMAGE BASED ACTIVE RANGING TO CAPTURE DYNAMIC SCENES

    Directory of Open Access Journals (Sweden)

    B. Jutzi

    2012-09-01

    Full Text Available Obtaining a 3D description of man-made and natural environments is a basic task in Computer Vision and Remote Sensing. To this end, laser scanning is currently one of the dominating techniques to gather reliable 3D information. The scanning principle inherently needs a certain time interval to acquire the 3D point cloud. On the other hand, new active sensors provide the possibility of capturing range information by images with a single measurement. With this new technique image-based active ranging is possible which allows capturing dynamic scenes, e.g. like walking pedestrians in a yard or moving vehicles. Unfortunately most of these range imaging sensors have strong technical limitations and are not yet sufficient for airborne data acquisition. It can be seen from the recent development of highly specialized (far-range imaging sensors – so called flash-light lasers – that most of the limitations could be alleviated soon, so that future systems will be equipped with improved image size and potentially expanded operating range. The presented work is a first step towards the development of methods capable for application of range images in outdoor environments. To this end, an experimental setup was set up for investigating these proposed possibilities. With the experimental setup a measurement campaign was carried out and first results will be presented within this paper.

  15. Unsynchronized scanning with a low-cost laser range finder for real-time range imaging

    Science.gov (United States)

    Hatipoglu, Isa; Nakhmani, Arie

    2017-06-01

    Range imaging plays an essential role in many fields: 3D modeling, robotics, heritage, agriculture, forestry, reverse engineering. One of the most popular range-measuring technologies is laser scanner due to its several advantages: long range, high precision, real-time measurement capabilities, and no dependence on lighting conditions. However, laser scanners are very costly. Their high cost prevents widespread use in applications. Due to the latest developments in technology, now, low-cost, reliable, faster, and light-weight 1D laser range finders (LRFs) are available. A low-cost 1D LRF with a scanning mechanism, providing the ability of laser beam steering for additional dimensions, enables to capture a depth map. In this work, we present an unsynchronized scanning with a low-cost LRF to decrease scanning period and reduce vibrations caused by stop-scan in synchronized scanning. Moreover, we developed an algorithm for alignment of unsynchronized raw data and proposed range image post-processing framework. The proposed technique enables to have a range imaging system for a fraction of the price of its counterparts. The results prove that the proposed method can fulfill the need for a low-cost laser scanning for range imaging for static environments because the most significant limitation of the method is the scanning period which is about 2 minutes for 55,000 range points (resolution of 250x220 image). In contrast, scanning the same image takes around 4 minutes in synchronized scanning. Once faster, longer range, and narrow beam LRFs are available, the methods proposed in this work can produce better results.

  16. Color Sensitivity Multiple Exposure Fusion using High Dynamic Range Image

    Directory of Open Access Journals (Sweden)

    Varsha Borole

    2014-02-01

    Full Text Available In this paper, we present a high dynamic range imaging (HDRI method using a capturing camera image using normally exposure, over exposure and under exposure. We make three different images from a multiple input image using local histogram stretching. Because the proposed method generated three histogram-stretched images from a multiple input image, ghost artifacts that are the result of the relative motion between the camera and objects during exposure time, are inherently removed. Therefore, the proposed method can be applied to a consumer compact camera to provide the ghost artifacts free HDRI. Experiments with several sets of test images with different exposures show that the proposed method gives a better performance than existing methods in terms of visual results and computation time.

  17. Aerial Triangulation Close-range Images with Dual Quaternion

    Directory of Open Access Journals (Sweden)

    SHENG Qinghong

    2015-05-01

    Full Text Available A new method for the aerial triangulation of close-range images based on dual quaternion is presented. Using dual quaternion to represent the spiral screw motion of the beam in the space, the real part of dual quaternion represents the angular elements of all the beams in the close-range area networks, the real part and the dual part of dual quaternion represents the line elements corporately. Finally, an aerial triangulation adjustment model based on dual quaternion is established, and the elements of interior orientation and exterior orientation and the object coordinates of the ground points are calculated. Real images and large attitude angle simulated images are selected to run the experiments of aerial triangulation. The experimental results show that the new method for the aerial triangulation of close-range images based on dual quaternion can obtain higher accuracy.

  18. A novel track imaging system as a range counter

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Z. [National Institute of Radiological Sciences (Japan); Matsufuji, N. [National Institute of Radiological Sciences (Japan); Tokyo Institute of Technology (Japan); Kanayama, S. [Chiba University (Japan); Ishida, A. [National Institute of Radiological Sciences (Japan); Tokyo Institute of Technology (Japan); Kohno, T. [Tokyo Institute of Technology (Japan); Koba, Y.; Sekiguchi, M.; Kitagawa, A.; Murakami, T. [National Institute of Radiological Sciences (Japan)

    2016-05-01

    An image-intensified, camera-based track imaging system has been developed to measure the tracks of ions in a scintillator block. To study the performance of the detector unit in the system, two types of scintillators, a dosimetrically tissue-equivalent plastic scintillator EJ-240 and a CsI(Tl) scintillator, were separately irradiated with carbon ion ({sup 12}C) beams of therapeutic energy from HIMAC at NIRS. The images of individual ion tracks in the scintillators were acquired by the newly developed track imaging system. The ranges reconstructed from the images are reported here. The range resolution of the measurements is 1.8 mm for 290 MeV/u carbon ions, which is considered a significant improvement on the energy resolution of the conventional ΔE/E method. The detector is compact and easy to handle, and it can fit inside treatment rooms for in-situ studies, as well as satisfy clinical quality assurance purposes.

  19. Cosmetic changes following surgery and accelerated partial breast irradiation using HDR interstitial brachytherapy : Evaluation by a multidisciplinary/multigender committee.

    Science.gov (United States)

    Soror, Tamer; Kovács, György; Seibold, Nina; Melchert, Corinna; Baumann, Kristin; Wenzel, Eike; Stojanovic-Rundic, Suzana

    2017-05-01

    Patients with early-stage breast cancer can benefit from adjuvant accelerated partial breast irradiation (APBI) following breast-conserving surgery (BCS). This work reports on cosmetic results following APBI using multicatheter high-dose-rate interstitial brachytherapy (HDR-IBT). Between 2006 and 2014, 114 patients received adjuvant APBI using multicatheter HDR-IBT. For each patient, two photographs were analyzed: the first was taken after surgery (baseline image) and the second at the last follow-up visit. Cosmesis was assessed by a multigender multidisciplinary team using the Harvard Breast Cosmesis Scale. Dose-volume histogram (DVH) parameters and the observed cosmetic results were investigated for potential correlations. The median follow-up period was 3.5 years (range 0.6-8.5 years). The final cosmetic scores were 30% excellent, 52% good, 14.5% fair, and 3.5% poor. Comparing the baseline and follow-up photographs, 59.6% of patients had the same score, 36% had a better final score, and 4.4% had a worse final score. Only lower target dose nonuniformity ratio (DNR) values (0.3 vs. 0.26; p = 0.009) were significantly associated with improved cosmetic outcome vs. same/worse cosmesis. APBI using multicatheter HDR-IBT adjuvant to BCS results in favorable final cosmesis. Deterioration in breast cosmesis occurs in less than 5% of patients. The final breast cosmetic outcome in patients treated with BCS and APBI using multicatheter HDR-IBT is influenced primarily by the cosmetic result of the surgery. A lower DNR value is significantly associated with a better cosmetic outcome.

  20. Evaluation of deformable image registration between external beam radiotherapy and HDR brachytherapy for cervical cancer with a 3D-printed deformable pelvis phantom.

    Science.gov (United States)

    Kadoya, Noriyuki; Miyasaka, Yuya; Nakajima, Yujiro; Kuroda, Yoshihiro; Ito, Kengo; Chiba, Mizuki; Sato, Kiyokazu; Dobashi, Suguru; Yamamoto, Takaya; Takahashi, Noriyoshi; Kubozono, Masaki; Takeda, Ken; Jingu, Keiichi

    2017-04-01

    In this study, we developed a 3D-printed deformable pelvis phantom for evaluating spatial DIR accuracy. We then evaluated the spatial DIR accuracies of various DIR settings for cervical cancer. A deformable female pelvis phantom was created based on patient CT data using 3D printing. To create the deformable uterus phantom, we first 3D printed both a model of uterus and a model of the internal cavities of the vagina and uterus. We then made a mold using the 3D printed uterus phantom. Finally, urethane was poured into the mold with the model of the internal cavities in place, creating the deformable uterus phantom with a cavity into which an applicator could be inserted. To create the deformable bladder phantom, we first 3D printed models of the bladder and of the same bladder scaled down by 2 mm. We then made a mold using the larger bladder model. Finally, silicone was poured into the mold with the smaller bladder model in place to create the deformable bladder phantom with a wall thickness of 2 mm. To emulate the anatomical bladder, water was poured into the created bladder. We acquired phantom image without applicator for EBRT. Then, we inserted the applicator into the phantom to simulate BT. In this situation, we scanned the phantom again to obtain the phantom image for BT. We performed DIR using the two phantom images in two cases: Case A, with full bladder (170 ml) in both EBRT and BT images; and Case B with full bladder in the BT image and half-full bladder (100 ml) in the EBRT image. DIR was evaluated using Dice similarity coefficients (DSCs) and 31 landmarks for the uterus and 25 landmarks for the bladder. A hybrid intensity and structure DIR algorithm implemented in RayStation with four DIR settings was evaluated. On visual inspection, reasonable agreement in shape of the uterus between the phantom and patient CT images was observed for both EBRT and BT, although some regional disagreements in shape of the bladder and rectum were apparent. The created

  1. Disocclusion of 3d LIDAR Point Clouds Using Range Images

    Science.gov (United States)

    Biasutti, P.; Aujol, J.-F.; Brédif, M.; Bugeau, A.

    2017-05-01

    This paper proposes a novel framework for the disocclusion of mobile objects in 3D LiDAR scenes aquired via street-based Mobile Mapping Systems (MMS). Most of the existing lines of research tackle this problem directly in the 3D space. This work promotes an alternative approach by using a 2D range image representation of the 3D point cloud, taking advantage of the fact that the problem of disocclusion has been intensively studied in the 2D image processing community over the past decade. First, the point cloud is turned into a 2D range image by exploiting the sensor's topology. Using the range image, a semi-automatic segmentation procedure based on depth histograms is performed in order to select the occluding object to be removed. A variational image inpainting technique is then used to reconstruct the area occluded by that object. Finally, the range image is unprojected as a 3D point cloud. Experiments on real data prove the effectiveness of this procedure both in terms of accuracy and speed.

  2. DISOCCLUSION OF 3D LIDAR POINT CLOUDS USING RANGE IMAGES

    Directory of Open Access Journals (Sweden)

    P. Biasutti

    2017-05-01

    Full Text Available This paper proposes a novel framework for the disocclusion of mobile objects in 3D LiDAR scenes aquired via street-based Mobile Mapping Systems (MMS. Most of the existing lines of research tackle this problem directly in the 3D space. This work promotes an alternative approach by using a 2D range image representation of the 3D point cloud, taking advantage of the fact that the problem of disocclusion has been intensively studied in the 2D image processing community over the past decade. First, the point cloud is turned into a 2D range image by exploiting the sensor’s topology. Using the range image, a semi-automatic segmentation procedure based on depth histograms is performed in order to select the occluding object to be removed. A variational image inpainting technique is then used to reconstruct the area occluded by that object. Finally, the range image is unprojected as a 3D point cloud. Experiments on real data prove the effectiveness of this procedure both in terms of accuracy and speed.

  3. IPIP: A New Approach to Inverse Planning for HDR Brachytherapy by Directly Optimizing Dosimetric Indices

    CERN Document Server

    Siauw, Timmy; Atamturk, Alper; Hsu, I-Chow; Pouliot, Jean; Goldberg, Ken

    2010-01-01

    Purpose: Many planning methods for high dose rate (HDR) brachytherapy treatment planning require an iterative approach. A set of computational parameters are hypothesized that will give a dose plan that meets dosimetric criteria. A dose plan is computed using these parameters, and if any dosimetric criteria are not met, the process is iterated until a suitable dose plan is found. In this way, the dose distribution is controlled by abstract parameters. The purpose of this study is to improve HDR brachytherapy planning by developing a new approach that directly optimizes the dose distribution based on dosimetric criteria. Method: We develop Inverse Planning by Integer Program (IPIP), an optimization model for computing HDR brachytherapy dose plans and a fast heuristic for it. We used our heuristic to compute dose plans for 20 anonymized prostate cancer patient image data sets from our clinic database. Dosimetry was evaluated and compared to dosimetric criteria. Results: Dose plans computed from IPIP satis?ed al...

  4. Calibration and control for range imaging in mobile robot navigation

    Energy Technology Data Exchange (ETDEWEB)

    Dorum, O.H. [Norges Tekniske Hoegskole, Trondheim (Norway). Div. of Computer Systems and Telematics; Hoover, A. [University of South Florida, Tampa, FL (United States). Dept. of Computer Science and Engineering; Jones, J.P. [Oak Ridge National Lab., TN (United States)

    1994-06-01

    This paper addresses some issues in the development of sensor-based systems for mobile robot navigation which use range imaging sensors as the primary source for geometric information about the environment. In particular, we describe a model of scanning laser range cameras which takes into account the properties of the mechanical system responsible for image formation and a calibration procedure which yields improved accuracy over previous models. In addition, we describe an algorithm which takes the limitations of these sensors into account in path planning and path execution. In particular, range imaging sensors are characterized by a limited field of view and a standoff distance -- a minimum distance nearer than which surfaces cannot be sensed. These limitations can be addressed by enriching the concept of configuration space to include information about what can be sensed from a given configuration, and using this information to guide path planning and path following.

  5. Ladar range image denoising by a nonlocal probability statistics algorithm

    Science.gov (United States)

    Xia, Zhi-Wei; Li, Qi; Xiong, Zhi-Peng; Wang, Qi

    2013-01-01

    According to the characteristic of range images of coherent ladar and the basis of nonlocal means (NLM), a nonlocal probability statistics (NLPS) algorithm is proposed in this paper. The difference is that NLM performs denoising using the mean of the conditional probability distribution function (PDF) while NLPS using the maximum of the marginal PDF. In the algorithm, similar blocks are found out by the operation of block matching and form a group. Pixels in the group are analyzed by probability statistics and the gray value with maximum probability is used as the estimated value of the current pixel. The simulated range images of coherent ladar with different carrier-to-noise ratio and real range image of coherent ladar with 8 gray-scales are denoised by this algorithm, and the results are compared with those of median filter, multitemplate order mean filter, NLM, median nonlocal mean filter and its incorporation of anatomical side information, and unsupervised information-theoretic adaptive filter. The range abnormality noise and Gaussian noise in range image of coherent ladar are effectively suppressed by NLPS.

  6. Passive millimeter-wave imaging at short and medium range

    Science.gov (United States)

    Essen, H.; Fuchs, H.-H.; Nötel, D.; Klöppel, F.; Pergande, P.; Stanko, S.

    2005-11-01

    During recent year's research on radiometric signatures, non-imaging, of the exhaust jet of missiles and imaging, on small vehicles in critical background scenarios were conducted by the mmW/submmW-group at FGAN-FHR. The equipment used for these investigations was of low technological status using simple single channel radiometers on a scanning pedestal. Meanwhile components of improved performance are available on a cooperative basis with the Institute for Applied Solid State Physics (Fraunhofer-IAF). Using such components a considerable progress concerning the temperature resolution and image generation time could be achieved. Emphasis has been put on the development of a demonstrator for CWD applications and on an imaging system for medium range applications, up to 200 m. The short range demonstrator is a scanning system operating alternatively at 35 GHz or 94 GHz to detect hidden materials as explosives, guns, knifes beneath the clothing. The demonstrator uses a focal plane array approach using 4 channels in azimuth, while mechanical scanning is used for the elevation. The medium range demonstrator currently employs a single channel radiometer on a pedestal for elevation over azimuth scanning. To improve the image quality, methods have been implemented using a Lorentzian algorithm with Wiener filtering.

  7. SU-E-T-574: Fessiblity of Using the Calypso System for HDR Interstitial Catheter Reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Li, J S; Ma, C [Fox Chase Cancer Center, Philadelphia, PA (United States)

    2014-06-01

    Purpose: It is always a challenge to reconstruct the interstitial catheter for high dose rate (HDR) brachytherapy on patient CT or MR images. This work aims to investigate the feasibility of using the Calypso system (Varian Medical, CA) for HDR catheter reconstruction utilizing its accuracy on tracking the electromagnetic transponder location. Methods: Experiment was done with a phantom that has a HDR interstitial catheter embedded inside. CT scan with a slice thickness of 1.25 mm was taken for this phantom with two Calypso beacon transponders in the catheter. The two transponders were connected with a wire. The Calypso system was used to record the beacon transponders’ location in real time when they were gently pulled out with the wire. The initial locations of the beacon transponders were used for registration with the CT image and the detected transponder locations were used for the catheter path reconstruction. The reconstructed catheter path was validated on the CT image. Results: The HDR interstitial catheter was successfully reconstructed based on the transponders’ coordinates recorded by the Calypso system in real time when the transponders were pulled in the catheter. After registration with the CT image, the shape and location of the reconstructed catheter are evaluated against the CT image and the result shows an accuracy of 2 mm anywhere in the Calypso detectable region which is within a 10 cm X 10 cm X 10 cm cubic box for the current system. Conclusion: It is feasible to use the Calypso system for HDR interstitial catheter reconstruction. The obstacle for its clinical usage is the size of the beacon transponder whose diameter is bigger than most of the interstitial catheters used in clinic. Developing smaller transponders and supporting software and hardware for this application is necessary before it can be adopted for clinical use.

  8. Calibration of the visual difference predictor for estimating visibility of JPEG2000 compression artifacts in CT images

    Science.gov (United States)

    Kim, Kil Joong; Mantiuk, Rafal; Lee, Kyoung Ho; Heidrich, Wolfgang

    2010-02-01

    Many visual difference predictors (VDPs) have used basic psychophysical data (such as ModelFest) to calibrate the algorithm parameters and to validate their performances. However, the basic psychophysical data often do not contain sufficient number of stimuli and its variations to test more complex components of a VDP. In this paper we calibrate the Visual Difference Predictor for High Dynamic Range images (HDR-VDP) using radiologists' experimental data for JPEG2000 compressed CT images which contain complex structures. Then we validate the HDR-VDP in predicting the presence of perceptible compression artifacts. 240 CT-scan images were encoded and decoded using JPEG2000 compression at four compression ratios (CRs). Five radiologists participated to independently determine if each image pair (original and compressed images) was indistinguishable or distinguishable. A threshold CR for each image, at which 50% of radiologists would detect compression artifacts, was estimated by fitting a psychometric function. The CT images compressed at the threshold CRs were used to calibrate the HDR-VDP parameters and to validate its prediction accuracy. Our results showed that the HDR-VDP calibrated for the CT image data gave much better predictions than the HDR-VDP calibrated to the basic psychophysical data (ModelFest + contrast masking data for sine gratings).

  9. Shadow correction in high dynamic range images for generating orthophotos

    Science.gov (United States)

    Suzuki, Hideo; Chikatsu, Hirofumi

    2011-07-01

    High dynamic range imagery is widely used in remote sensing. With the widespread use of aerial digital cameras such as the DMC, ADS40, RMK-D, and UltraCamD, high dynamic range imaging is generally expected for generating minuteness orthophotos in digital aerial photogrammetry. However, high dynamic range images (12-bit, 4,096 gray levels) are generally compressed into an 8-bit depth digital image (256 gray levels) owing to huge amount of data and interface with peripherals such as monitors and printers. This means that a great deal of image data is eliminated from the original image, and this introduces a new shadow problem. In particular, the influence of shadows in urban areas causes serious problems when generating minuteness orthophotos and performing house detection. Therefore, shadow problems can be solved by addressing the image compression problems. There is a large body of literature on image compression techniques such as logarithmic compression and tone mapping algorithms. However, logarithmic compression tends to cause loss of details in dark and/or light areas. Furthermore, the logarithmic method intends to operate on the full scene. This means that high-resolution luminance information can not be obtained. Even though tone mapping algorithms have the ability to operate over both full scene and local scene, background knowledge is required. To resolve the shadow problem in digital aerial photogrammetry, shadow areas should be recognized and corrected automatically without the loss of luminance information. To this end, a practical shadow correction method using 12-bit real data acquired by DMC is investigated in this paper.

  10. Range-gated imaging for near-field target identification

    Energy Technology Data Exchange (ETDEWEB)

    Yates, G.J.; Gallegos, R.A.; McDonald, T.E. [and others

    1996-12-01

    The combination of two complementary technologies developed independently at Los Alamos National Laboratory (LANL) and Sandia National Laboratory (SNL) has demonstrated feasibility of target detection and image capture in a highly light-scattering, medium. The technique uses a compact SNL developed Photoconductive Semiconductor Switch/Laser Diode Array (PCSS/LDA) for short-range (distances of 8 to 10 m) large Field-Of-View (FOV) target illumination. Generation of a time-correlated echo signal is accomplished using a photodiode. The return image signal is recorded with a high-speed shuttered Micro-Channel-Plate Image Intensifier (MCPII), declined by LANL and manufactured by Philips Photonics. The MCPII is rated using a high-frequency impedance-matching microstrip design to produce 150 to 200 ps duration optical exposures. The ultra first shuttering producer depth resolution of a few inches along the optic axis between the MCPII and the target, producing enhanced target images effectively deconvolved from noise components from the scattering medium in the FOV. The images from the MCPII are recorded with an RS-170 Charge-Coupled-Device camera and a Big Sky, Beam Code, PC-based digitizer frame grabber and analysis package. Laser pulse data were obtained by the but jitter problems and spectral mismatches between diode spectral emission wavelength and MCPII photocathode spectral sensitivity prevented the capture of fast gating imaging with this demonstration system. Continued development of the system is underway.

  11. The emerging versatility of a scannerless range imager

    Energy Technology Data Exchange (ETDEWEB)

    Sackos, J.; Bradley, B.; Nellums, B.; Diegert, C.

    1996-04-01

    Sandia National Laboratories is nearing the completion of the initial development of a unique type of range imaging sensor. This innovative imaging optical radar is based on an active flood-light scene illuminator and an image intensified CCD camera receiver. It is an all solid-state device (no moving parts) and offers significant size, performance, reliability, simplicity, and affordability advantages over other types of 3-D sensor technologies, including: scanned laser radar, stereo vision, and structured lighting. The sensor is based on low cost, commercially available hardware, and is very well suited for affordable application to a wide variety of military and commercial uses, including: munition guidance, target recognition, robotic vision, automated inspection, driver enhanced vision, collision avoidance, site security and monitoring, terrain mapping, and facility surveying. This paper reviews the sensor technology and its development for the advanced conventional munition guidance application, and discusses a few of the many other emerging applications for this new innovative sensor technology.

  12. Close-range imaging and research priorities in Europe

    Directory of Open Access Journals (Sweden)

    P. Patias

    2014-06-01

    Full Text Available Since 1984, the European Union’s Framework Program for Research and Innovation has been the main instrument for funding research. Specific priorities, objectives and types of funded activities vary between funding periods. Horizon 2020 is the biggest EU Research and Innovation programme ever with nearly € 80 billion of funding available over 7 years (2014–2020. H2020 is based on three pillars: (i Excellent science, (ii Industrial leadership, (iii Societal challenges. The current economic crisis in Europe and elsewhere leads to extended shortage of research budgets in national levels, which in turn leads researchers to search funds in the highly competitive transnational research instruments, as H2020. This paper : - draws the overall picture of Horizon 2020 - investigates the position of close-range imaging technologies, applications and research areas - presents the research challenges in H2020 that offer funding opportunities in close-range imaging

  13. Adaptive Optics for Satellite Imaging and Space Debris Ranging

    Science.gov (United States)

    Bennet, F.; D'Orgeville, C.; Price, I.; Rigaut, F.; Ritchie, I.; Smith, C.

    Earth's space environment is becoming crowded and at risk of a Kessler syndrome, and will require careful management for the future. Modern low noise high speed detectors allow for wavefront sensing and adaptive optics (AO) in extreme circumstances such as imaging small orbiting bodies in Low Earth Orbit (LEO). The Research School of Astronomy and Astrophysics (RSAA) at the Australian National University have been developing AO systems for telescopes between 1 and 2.5m diameter to image and range orbiting satellites and space debris. Strehl ratios in excess of 30% can be achieved for targets in LEO with an AO loop running at 2kHz, allowing the resolution of small features (system developed at RSAA consists of a high speed EMCCD Shack-Hartmann wavefront sensor, a deformable mirror (DM), and realtime computer (RTC), and an imaging camera. The system works best as a laser guide star system but will also function as a natural guide star AO system, with the target itself being the guide star. In both circumstances tip-tilt is provided by the target on the imaging camera. The fast tip-tilt modes are not corrected optically, and are instead removed by taking images at a moderate speed (>30Hz) and using a shift and add algorithm. This algorithm can also incorporate lucky imaging to further improve the final image quality. A similar AO system for space debris ranging is also in development in collaboration with Electro Optic Systems (EOS) and the Space Environment Management Cooperative Research Centre (SERC), at the Mount Stromlo Observatory in Canberra, Australia. The system is designed for an AO corrected upward propagated 1064nm pulsed laser beam, from which time of flight information is used to precisely range the target. A 1.8m telescope is used for both propagation and collection of laser light. A laser guide star, Shack-Hartmann wavefront sensor, and DM are used for high order correction, and tip-tilt correction provided by reflected sunlight from the target. The

  14. Dosimetry revisited for the HDR {sup 192}Ir brachytherapy source model mHDR-v2

    Energy Technology Data Exchange (ETDEWEB)

    Granero, Domingo; Vijande, Javier; Ballester, Facundo; Rivard, Mark J. [Radiation Physics Department, ERESA, Hospital General Universitario, E-46014 Valencia (Spain); Department of Atomic, Molecular, and Nuclear Physics, University of Valencia, E-46100 Burjassot (Spain) and IFIC, CSIC-University of Valencia, E-46100 Burjassot (Spain); Department of Radiation Oncology, Tufts University School of Medicine, Boston, Massachusetts 02111 (United States)

    2011-01-15

    Purpose: Recently, the manufacturer of the HDR {sup 192}Ir mHDR-v2 brachytherapy source reported small design changes (referred to herein as mHDR-v2r) that are within the manufacturing tolerances but may alter the existing dosimetric data for this source. This study aimed to (1) check whether these changes affect the existing dosimetric data published for this source; (2) obtain new dosimetric data in close proximity to the source, including the contributions from {sup 192}Ir electrons and considering the absence of electronic equilibrium; and (3) obtain scatter dose components for collapsed cone treatment planning system implementation. Methods: Three different Monte Carlo (MC) radiation transport codes were used: MCNP5, PENELOPE2008, and GEANT4. The source was centrally positioned in a 40 cm radius water phantom. Absorbed dose and collision kerma were obtained using 0.1 mm (0.5 mm) thick voxels to provide high-resolution dosimetry near (far from) the source. Dose-rate distributions obtained with the three MC codes were compared. Results: Simulations of mHDR-v2 and mHDR-v2r designs performed with three radiation transport codes showed agreement typically within 0.2% for r{>=}0.25 cm. Dosimetric contributions from source electrons were significant for r<0.25 cm. The dose-rate constant and radial dose function were similar to those from previous MC studies of the mHDR-v2 design. The 2D anisotropy function also coincided with that of the mHDR-v2 design for r{>=}0.25 cm. Detailed results of dose distributions and scatter components are presented for the modified source design. Conclusions: Comparison of these results to prior MC studies showed agreement typically within 0.5% for r{>=}0.25 cm. If dosimetric data for r<0.25 cm are not needed, dosimetric results from the prior MC studies will be adequate.

  15. Imaging using long range dipolar field effects Nuclear magnetic resonance

    CERN Document Server

    Gutteridge, S

    2002-01-01

    The work in this thesis has been undertaken by the except where indicated in reference, within the Magnetic Resonance Centre, at the University of Nottingham during the period from October 1998 to March 2001. This thesis details the different characteristics of the long range dipolar field and its application to magnetic resonance imaging. The long range dipolar field is usually neglected in nuclear magnetic resonance experiments, as molecular tumbling decouples its effect at short distances. However, in highly polarised samples residual long range components have a significant effect on the evolution of the magnetisation, giving rise to multiple spin echoes and unexpected quantum coherences. Three applications utilising these dipolar field effects are documented in this thesis. The first demonstrates the spatial sensitivity of the signal generated via dipolar field effects in structured liquid state samples. The second utilises the signal produced by the dipolar field to create proton spin density maps. Thes...

  16. A gEUD-based inverse planning technique for HDR prostate brachytherapy: feasibility study.

    Science.gov (United States)

    Giantsoudi, D; Baltas, D; Karabis, A; Mavroidis, P; Zamboglou, N; Tselis, N; Shi, C; Papanikolaou, N

    2013-04-01

    The purpose of this work was to study the feasibility of a new inverse planning technique based on the generalized equivalent uniform dose for image-guided high dose rate (HDR) prostate cancer brachytherapy in comparison to conventional dose-volume based optimization. The quality of 12 clinical HDR brachytherapy implants for prostate utilizing HIPO (Hybrid Inverse Planning Optimization) is compared with alternative plans, which were produced through inverse planning using the generalized equivalent uniform dose (gEUD). All the common dose-volume indices for the prostate and the organs at risk were considered together with radiobiological measures. The clinical effectiveness of the different dose distributions was investigated by comparing dose volume histogram and gEUD evaluators. Our results demonstrate the feasibility of gEUD-based inverse planning in HDR brachytherapy implants for prostate. A statistically significant decrease in D10 or/and final gEUD values for the organs at risk (urethra, bladder, and rectum) was found while improving dose homogeneity or dose conformity of the target volume. Following the promising results of gEUD-based optimization in intensity modulated radiation therapy treatment optimization, as reported in the literature, the implementation of a similar model in HDR brachytherapy treatment plan optimization is suggested by this study. The potential of improved sparing of organs at risk was shown for various gEUD-based optimization parameter protocols, which indicates the ability of this method to adapt to the user's preferences.

  17. A gEUD-based inverse planning technique for HDR prostate brachytherapy: Feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Giantsoudi, D. [Department of Radiological Sciences, University of Texas Health Sciences Center, San Antonio, Texas 78229 (United States); Department of Radiation Oncology, Francis H. Burr Proton Therapy Center, Boston, Massachusetts 02114 (United States); Baltas, D. [Department of Medical Physics and Engineering, Strahlenklinik, Klinikum Offenbach GmbH, 63069 Offenbach (Germany); Nuclear and Particle Physics Section, Physics Department, University of Athens, 15701 Athens (Greece); Karabis, A. [Pi-Medical Ltd., Athens 10676 (Greece); Mavroidis, P. [Department of Radiological Sciences, University of Texas Health Sciences Center, San Antonio, Texas 78299 and Department of Medical Radiation Physics, Karolinska Institutet and Stockholm University, 17176 (Sweden); Zamboglou, N.; Tselis, N. [Strahlenklinik, Klinikum Offenbach GmbH, 63069 Offenbach (Germany); Shi, C. [St. Vincent' s Medical Center, 2800 Main Street, Bridgeport, Connecticut 06606 (United States); Papanikolaou, N. [Department of Radiological Sciences, University of Texas Health Sciences Center, San Antonio, Texas 78299 (United States)

    2013-04-15

    Purpose: The purpose of this work was to study the feasibility of a new inverse planning technique based on the generalized equivalent uniform dose for image-guided high dose rate (HDR) prostate cancer brachytherapy in comparison to conventional dose-volume based optimization. Methods: The quality of 12 clinical HDR brachytherapy implants for prostate utilizing HIPO (Hybrid Inverse Planning Optimization) is compared with alternative plans, which were produced through inverse planning using the generalized equivalent uniform dose (gEUD). All the common dose-volume indices for the prostate and the organs at risk were considered together with radiobiological measures. The clinical effectiveness of the different dose distributions was investigated by comparing dose volume histogram and gEUD evaluators. Results: Our results demonstrate the feasibility of gEUD-based inverse planning in HDR brachytherapy implants for prostate. A statistically significant decrease in D{sub 10} or/and final gEUD values for the organs at risk (urethra, bladder, and rectum) was found while improving dose homogeneity or dose conformity of the target volume. Conclusions: Following the promising results of gEUD-based optimization in intensity modulated radiation therapy treatment optimization, as reported in the literature, the implementation of a similar model in HDR brachytherapy treatment plan optimization is suggested by this study. The potential of improved sparing of organs at risk was shown for various gEUD-based optimization parameter protocols, which indicates the ability of this method to adapt to the user's preferences.

  18. Dynamic range compression and detail enhancement algorithm for infrared image.

    Science.gov (United States)

    Sun, Gang; Liu, Songlin; Wang, Weihua; Chen, Zengping

    2014-09-10

    For infrared imaging systems with high sampling width applying to the traditional display device or real-time processing system with 8-bit data width, this paper presents a new high dynamic range compression and detail enhancement (DRCDDE) algorithm for infrared images. First, a bilateral filter is adopted to separate the original image into two parts: the base component that contains large-scale signal variations, and the detail component that contains high-frequency information. Then, the operator model for DRC with local-contrast preservation is established, along with a new proposed nonlinear intensity transfer function (ITF) to implement adaptive DRC of the base component. For the detail component, depending on the local statistical characteristics, we set up suitable intensity level extension criteria to enhance the low-contrast details and suppress noise. Finally, the results of the two components are recombined with a weighted coefficient. Experiment results by real infrared data, and quantitative comparison with other well-established methods, show the better performance of the proposed algorithm. Furthermore, the technique could effectively project a dim target while suppressing noise, which is beneficial to image display and target detection.

  19. Active resonant subwavelength grating for scannerless range imaging sensors.

    Energy Technology Data Exchange (ETDEWEB)

    Kemme, Shanalyn A.; Nellums, Robert O.; Boye, Robert R.; Peters, David William

    2006-11-01

    In this late-start LDRD, we will present a design for a wavelength-agile, high-speed modulator that enables a long-term vision for the THz Scannerless Range Imaging (SRI) sensor. It takes the place of the currently-utilized SRI micro-channel plate which is limited to photocathode sensitive wavelengths (primarily in the visible and near-IR regimes). Two of Sandia's successful technologies--subwavelength diffractive optics and THz sources and detectors--are poised to extend the capabilities of the SRI sensor. The goal is to drastically broaden the SRI's sensing waveband--all the way to the THz regime--so the sensor can see through image-obscuring, scattering environments like smoke and dust. Surface properties, such as reflectivity, emissivity, and scattering roughness, vary greatly with the illuminating wavelength. Thus, objects that are difficult to image at the SRI sensor's present near-IR wavelengths may be imaged more easily at the considerably longer THz wavelengths (0.1 to 1mm). The proposed component is an active Resonant Subwavelength Grating (RSG). Sandia invested considerable effort on a passive RSG two years ago, which resulted in a highly-efficient (reflectivity greater than gold), wavelength-specific reflector. For this late-start LDRD proposal, we will transform the passive RSG design into an active laser-line reflector.

  20. Aquarious Mountain Area, Arizona: APossible HDR Prospect

    Energy Technology Data Exchange (ETDEWEB)

    West, F.G.; Laughlin, A.W.

    1979-05-01

    Exploration for Hot Dry Rock (HDR) requires the ability to delineate areas of thermal enhancement. It is likely that some of these areas will exhibit various sorts of anomalous conditions such as seismic transmission delays, low seismic velocities, high attenuation of seismic waves, high electrical conductivity in the crust, and a relatively shallow depth to Curie point of Magnetization. The Aquarius Mountain area of northwest Arizona exhibits all of these anomalies. The area is also a regional Bouguer gravity low, which may indicate the presence of high silica type rocks that often have high rates of radioactive heat generation. The one deficiency of the area as a HDR prospect is the lack of a thermal insulating blanket.

  1. Pile volume measurement by range imaging camera in indoor environment

    Directory of Open Access Journals (Sweden)

    C. Altuntas

    2014-06-01

    Full Text Available Range imaging (RIM camera is recent technology in 3D location measurement. The new study areas have been emerged in measurement and data processing together with RIM camera. It has low-cost and fast measurement technique compared to the current measurement techniques. However its measurement accuracy varies according to effects resulting from the device and the environment. The direct sunlight is affect measurement accuracy of the camera. Thus, RIM camera should be used for indoor measurement. In this study gravel pile volume was measured by SwissRanger SR4000 camera. The measured volume is acquired as different 8.13% from the known.

  2. Range imaging results from polar mesosphere summer echoes

    Science.gov (United States)

    Zecha, Marius; Hoffmann, Peter; Rapp, Markus; Chen, Jenn-Shyong

    The range resolution of pulsed radars is usually limited by the transmitting pulse length and the sampling time. The so-called range imaging (RIM) has been developed to reduce these lim-itations. To apply this method the radar operates alternately over a set of distinct frequencies. Then the phase differences of the receiving signals can be used for optimization methods to generate high-resolution maps of reflections as function of range insight the pulse length. The technique has been implemented on the ALWIN VHF radar in Andenes (69) and the OSWIN VHF radar in Kühlungsborn (54N). Here we present results of the RIM method from measurements in polar mesosphere summer echoes -PMSE. These strong radar echoes are linked to ice particle clouds in the mesopause region. The dynamic of the PMSE can be reflected very well by RIM. The movement of PMSE and the edges of the extension can be tracked with a high altitude resolution. Comparisons between simultaneous measurements by RIM and by standard radar techniques demonstrate the advan-tages of RIM. Wave structures can be identified with RIM whereas they are not detectable with the lesser resolution of the standard measurements. Gravity wave parameter associated with these variations are estimated using the simultaneous measured velocity field.

  3. Strategies for registering range images from unknown camera positions

    Science.gov (United States)

    Bernardini, Fausto; Rushmeier, Holly E.

    2000-03-01

    We describe a project to construct a 3D numerical model of Michelangelo's Florentine Pieta to be used in a study of the sculpture. Here we focus on the registration of the range images used to construct the model. The major challenge was the range of length scales involved. A resolution of 1 mm or less required for the 2.25 m tall piece. To achieve this resolution, we could only acquire an area of 20 by 20 cm per scan. A total of approximately 700 images were required. Ideally, a tracker would be attached to the scanner to record position and pose. The use of a tracker was not possible in the field. Instead, we used a crude-to-fine approach to registering the meshes to one another. The crudest level consisted of pairwise manual registration, aided by texture maps containing laser dots that were projected onto the sculpture. This crude alignment was refined by an automatic registration of laser dot centers. In this phase, we found that consistency constraints on dot matches were essential to obtaining accurate results. The laser dot alignment was refined by an automatic registration of laser dot centers. In this phase, we found that consistency constraints on dot matches were essential to obtaining accurate results. The laser dot alignment was further refined using a variation of the ICP algorithm developed by Besl and McKay. In the application of ICP to global registration, we developed a method to avoid one class of local minima by finding a set of points, rather than the single point, that matches each candidate point.

  4. Characterization of HDR Ir-192 source for 3D planning system

    Energy Technology Data Exchange (ETDEWEB)

    Fonseca, Gabriel P.; Yoriyaz, Helio; Antunes, Paula C.G.; Siqueira, Paulo T.D., E-mail: gabriel.fonseca@usp.b, E-mail: hyoriyaz@ipen.b, E-mail: ptsiquei@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Rubo, Rodrigo [Universidade de Sao Paulo (HC/FMUSP), Sao Paulo, SP (Brazil). Hospital das Clinicas. Servico de Radioterapia; Minamisawa, Renato A., E-mail: renato.minamisawa@psi.c [Paul Scherrer Institut (PSI), Villigen (Switzerland); Ferreira, Louise A. [Universidade Estadual de Maringa (UEM), PR (Brazil). Fac. de Medicina

    2011-07-01

    Brachytherapy treatment involves surgical or cavitary insertion of radioactive sources for diseases treatments, such as: lung, gynecologic or prostate cancer. This technique has great ability to administer high doses to the tumor, with adjacent normal tissue preservation equal or better than external beam radiation therapy. Several innovations have been incorporated in this treatment technique, such as, 3D treatment planning system and computer guided sources. In detriment to scientific advances there are no protocols that relate dose with tumor volume, organs or A point, established by ICRU38 and used to prescribe dose in treatment planning system. Several international studies, like as EMBRACE, the multicentre international study, has been trying to correlate the dose volume using 3D planning systems and medical images, as those obtained by CT or MRI, to establish treatment protocols. With the objective of analyzing the 3D dose distribution, a micro Selectron-HDR remote afterloading device for high dose-rate (HDR) was characterized in the present work. Through the data provided by the manufacturer the source was simulated, using the MCNP5 code to calculate American Association of Physicists in Medicine Task Group No. 43 report (AAPM TG43) specified parameters. The simulations have shown great agreement when compared to the ONCENTRA planning system results and those provided by literature. The micro Selectron-HDR remote afterloading device will be utilized to simulate 3D dose distribution through CT images processed by an auxiliary software which process DICOM images. (author)

  5. HDR color conversion with varying distortion metrics

    Science.gov (United States)

    Norkin, Andrey

    2016-09-01

    The paper compares three algorithms, which attenuate artifacts that may appear in HDR video in Y'CbCr 4:2:0 format. The algorithms attenuate artifacts in colors at the color gamut boundaries while also improving the objective quality. Two closed form solutions demonstrate the same subjective quality as the iterative approach, while being computationally simpler. One of the closed form solutions also shows similar objective results to the iterative algorithm. The choice of the upsampling filter in the pre-processing stage is important and may negatively affect both the objective and subjective quality if there is a mismatch with the upsampling filter used in the reconstruction.

  6. External radiation and HDR-brachytherapy in the treatment of breast cancer. Externe Bestrahlung und interstitielle HDR-Brachytherapie in der Bestrahlung des Mammakarzinoms

    Energy Technology Data Exchange (ETDEWEB)

    Track, C. (Abt. fuer Radioonkologie, Krankenhaus der Barmherzigen Schwestern, Linz (Austria)); Seewald, D.H. (Abt. fuer Radioonkologie, Krankenhaus der Barmherzigen Schwestern, Linz (Austria)); Zoidl, J.P. (Abt. fuer Radioonkologie, Krankenhaus der Barmherzigen Schwestern, Linz (Austria)); Hammer, J. (Abt. fuer Radioonkologie, Krankenhaus der Barmherzigen Schwestern, Linz (Austria))

    1994-04-01

    In the breast conserving management of mammary cancer a high-dose-rate (HDR)-Iridium-192 source is used for interstitial boosting of the primary tumor site after external radiotherapy. We want to show the clinical results and side effects and to demonstrate the safe use of a HDR source. From December 1984 until November 1988, 154 patients with breast cancer stage T1-2, N0-1 were treated by conservative surgery and radiation. A dose of 45 to 50 Gy was given to the whole breast by external radiotherapy, and the previous tumor area was boosted by an interstitial implant with Iridium-192 HDR. We applied 10 Gy in one or two fractions. The mean follow-up period of survivors is 76 months (range 57 to 107 months). In 36 patients failures occured: eight patients (5%) developed local recurrences, 31 patients (20%) had distant metastases, and 19 (12%) died with cancer. The Kaplan-Meier estimation for five year overall survival is 86.9%, for disease-specific survival 89.3%, for local control 95.8%, and for disease free survival 80.1%. The most frequent late effects were telangiectasia (11%), fibrotic masses in the previous tumor area (6.5%), and lymphedema of the arm (6.5%). No serious complications could be observed. (orig./MG)

  7. Automatic face segmentation and facial landmark detection in range images.

    Science.gov (United States)

    Pamplona Segundo, Maurício; Silva, Luciano; Bellon, Olga Regina Pereira; Queirolo, Chauã C

    2010-10-01

    We present a methodology for face segmentation and facial landmark detection in range images. Our goal was to develop an automatic process to be embedded in a face recognition system using only depth information as input. To this end, our segmentation approach combines edge detection, region clustering, and shape analysis to extract the face region, and our landmark detection approach combines surface curvature information and depth relief curves to find the nose and eye landmarks. The experiments were performed using the two available versions of the Face Recognition Grand Challenge database and the BU-3DFE database, in order to validate our proposed methodology and its advantages for 3-D face recognition purposes. We present an analysis regarding the accuracy of our segmentation and landmark detection approaches. Our results were better compared to state-of-the-art works published in the literature. We also performed an evaluation regarding the influence of the segmentation process in our 3-D face recognition system and analyzed the improvements obtained when applying landmark-based techniques to deal with facial expressions.

  8. A feasibility study of applying thermal imaging to assist quality assurance of high-dose rate brachytherapy

    Directory of Open Access Journals (Sweden)

    Xiaofeng Zhu

    2017-01-01

    Conclusion: Thermal imaging could be a feasible tool to visualize HDR source dwell positions and verify source integrity. Potentially, patient safety and treatment quality may be improved by integrating thermal measurements into HDR QA procedures.

  9. Dosimetric evaluation of PLATO and Oncentra treatment planning systems for High Dose Rate (HDR) brachytherapy gynecological treatments

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Hardev; De La Fuente Herman, Tania; Showalter, Barry; Thompson, Spencer J.; Syzek, Elizabeth J.; Herman, Terence; Ahmad, Salahuddin [Department of Radiation Oncology, Peggy and Charles Stephenson Oklahoma Cancer Center, University of Oklahoma Health Sciences Center, Oklahoma City, OK 73104 (United States)

    2012-10-23

    This study compares the dosimetric differences in HDR brachytherapy treatment plans calculated with Nucletron's PLATO and Oncentra MasterPlan treatment planning systems (TPS). Ten patients (1 T1b, 1 T2a, 6 T2b, 2 T4) having cervical carcinoma, median age of 43.5 years (range, 34-79 years) treated with tandem and ring applicator in our institution were selected retrospectively for this study. For both Plato and Oncentra TPS, the same orthogonal films anterior-posterior (AP) and lateral were used to manually draw the prescription and anatomical points using definitions from the Manchester system and recommendations from the ICRU report 38. Data input for PLATO was done using a digitizer and Epson Expression 10000XL scanner was used for Oncentra where the points were selected on the images in the screen. The prescription doses for these patients were 30 Gy to points right A (RA) and left A (LA) delivered in 5 fractions with Ir-192 HDR source. Two arrangements: one dwell position and two dwell positions on the tandem were used for dose calculation. The doses to the patient points right B (RB) and left B (LB), and to the organs at risk (OAR), bladder and rectum for each patient were calculated. The mean dose and the mean percentage difference in dose calculated by the two treatment planning systems were compared. Paired t-tests were used for statistical analysis. No significant differences in mean RB, LB, bladder and rectum doses were found with p-values > 0.14. The mean percent difference of doses in RB, LB, bladder and rectum are found to be less than 2.2%, 1.8%, 1.3% and 2.2%, respectively. Dose calculations based on the two different treatment planning systems were found to be consistent and the treatment plans can be made with either system in our department without any concern.

  10. Processor for Real-Time Atmospheric Compensation in Long-Range Imaging Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Long-range imaging is a critical component to many NASA applications including range surveillance, launch tracking, and astronomical observation. However,...

  11. Long-Range Reconnaissance Imager on New Horizons

    Science.gov (United States)

    Cheng, A. F.; Weaver, H. A.; Conard, S. J.; Hayes, J. R.; Morgan, M. F.; Noble, M.; Taylor, H. W.; Barnouin, O.; Boldt, J. D.; Darlington, E. H.; Grey, M. P.; Magee, T.; Rossano, E.; Schlemm, C.; Kosakowski, K. E.; Sampath, D.

    2012-10-01

    LORRI is the highest resolution imager on the New Horizons (NH) mission to Pluto and the Kuiper belt. LORRI produced superb images of Jupiter and its satellites even though those bodies are ~35 times brighter than bodies in the Pluto system.

  12. Objective method to report planner-independent skin/rib maximal dose in balloon-based high dose rate (HDR) brachytherapy for breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yongbok; Trombetta, Mark G. [Department of Radiation Oncology, Allegheny General Hospital, Pittsburgh, Pennsylvania 15212 (United States) and Drexel University College of Medicine, Allegheny Campus, Pittsburgh, Pennsylvania 15212 (United States)

    2011-04-15

    Purpose: An objective method was proposed and compared with a manual selection method to determine planner-independent skin and rib maximal dose in balloon-based high dose rate (HDR) brachytherapy planning. Methods: The maximal dose to skin and rib was objectively extracted from a dose volume histogram (DVH) of skin and rib volumes. A virtual skin volume was produced by expanding the skin surface in three dimensions (3D) external to the breast with a certain thickness in the planning computed tomography (CT) images. Therefore, the maximal dose to this volume occurs on the skin surface the same with a conventional manual selection method. The rib was also delineated in the planning CT images and its maximal dose was extracted from its DVH. The absolute (Abdiff=|D{sub max}{sup Man}-D{sub max}{sup DVH}|) and relative (Rediff[%]=100x(|D{sub max}{sup Man}-D{sub max}{sup DVH}|)/D{sub max}{sup DVH}) maximal skin and rib dose differences between the manual selection method (D{sub max}{sup Man}) and the objective method (D{sub max}{sup DVH}) were measured for 50 balloon-based HDR (25 MammoSite and 25 Contura) patients. Results: The average{+-}standard deviation of maximal dose difference was 1.67%{+-}1.69% of the prescribed dose (PD). No statistical difference was observed between MammoSite and Contura patients for both Abdiff and Rediff[%] values. However, a statistically significant difference (p value <0.0001) was observed in maximal rib dose difference compared with maximal skin dose difference for both Abdiff (2.30%{+-}1.71% vs 1.05%{+-}1.43%) and Rediff[%] (2.32%{+-}1.79% vs 1.21%{+-}1.41%). In general, rib has a more irregular contour and it is more proximally located to the balloon for 50 HDR patients. Due to the inverse square law factor, more dose difference was observed in higher dose range (D{sub max}>90%) compared with lower dose range (D{sub max}<90%): 2.16%{+-}1.93% vs 1.19%{+-}1.25% with p value of 0.0049. However, the Rediff[%] analysis eliminated the

  13. IPIP: A new approach to inverse planning for HDR brachytherapy by directly optimizing dosimetric indices

    Energy Technology Data Exchange (ETDEWEB)

    Siauw, Timmy; Cunha, Adam; Atamtuerk, Alper; Hsu, I-Chow; Pouliot, Jean; Goldberg, Ken [Department of Civil and Environmental Engineering, University of California, Berkeley, 760 Davis Hall, Berkeley, California 94720-1710 (United States); Department of Radiation Oncology, University of California, San Francisco, Comprehensive Cancer Center, 1600 Divisadero Street, Suite H1031, San Francisco, California 94143-1708 (United States); Department of Industrial Engineering and Operations, University of California, Berkeley, 4141 Etcheverry Hall, Berkeley, California 94720-1777 (United States); Department of Radiation Oncology, University of California, San Francisco, Comprehensive Cancer Center, 1600 Divisadero Street, Suite H1031, San Francisco, California 94143-1708 (United States); Department of Industrial Engineering and Operations Research and Department of Electrical Engineering and Computer Science, University of California, Berkeley, 4141 Etcheverry Hall, Berkeley, California 94720-1777 (United States)

    2011-07-15

    Purpose: Many planning methods for high dose rate (HDR) brachytherapy require an iterative approach. A set of computational parameters are hypothesized that will give a dose plan that meets dosimetric criteria. A dose plan is computed using these parameters, and if any dosimetric criteria are not met, the process is iterated until a suitable dose plan is found. In this way, the dose distribution is controlled by abstract parameters. The purpose of this study is to develop a new approach for HDR brachytherapy by directly optimizing the dose distribution based on dosimetric criteria. Methods: The authors developed inverse planning by integer program (IPIP), an optimization model for computing HDR brachytherapy dose plans and a fast heuristic for it. They used their heuristic to compute dose plans for 20 anonymized prostate cancer image data sets from patients previously treated at their clinic database. Dosimetry was evaluated and compared to dosimetric criteria. Results: Dose plans computed from IPIP satisfied all given dosimetric criteria for the target and healthy tissue after a single iteration. The average target coverage was 95%. The average computation time for IPIP was 30.1 s on an Intel(R) Core{sup TM}2 Duo CPU 1.67 GHz processor with 3 Gib RAM. Conclusions: IPIP is an HDR brachytherapy planning system that directly incorporates dosimetric criteria. The authors have demonstrated that IPIP has clinically acceptable performance for the prostate cases and dosimetric criteria used in this study, in both dosimetry and runtime. Further study is required to determine if IPIP performs well for a more general group of patients and dosimetric criteria, including other cancer sites such as GYN.

  14. Detection of pitting corrosion in steel using image processing

    OpenAIRE

    Ghosh, Bidisha; Pakrashi, Vikram; Schoefs, Franck

    2010-01-01

    This paper presents an image processing based detection method for detecting pitting corrosion in steel structures. High Dynamic Range (HDR) imaging has been carried out in this regard to demonstrate the effectiveness of such relatively inexpensive techniques that are of immense benefit to Non – Destructive – Tesing (NDT) community. The pitting corrosion of a steel sample in marine environment is successfully detected in this paper using the proposed methodology. It is observed, that the prop...

  15. Objective method to report planner-independent skin/rib maximal dose in balloon-based high dose rate (HDR) brachytherapy for breast cancer.

    Science.gov (United States)

    Kim, Yongbok; Trombetta, Mark G

    2011-04-01

    An objective method was proposed and compared with a manual selection method to determine planner-independent skin and rib maximal dose in balloon-based high dose rate (HDR) brachytherapy planning. The maximal dose to skin and rib was objectively extracted from a dose volume histogram (DVH) of skin and rib volumes. A virtual skin volume was produced by expanding the skin surface in three dimensions (3D) external to the breast with a certain thickness in the planning computed tomography (CT) images. Therefore, the maximal dose to this volume occurs on the skin surface the same with a conventional manual selection method. The rib was also delineated in the planning CT images and its maximal dose was extracted from its DVH. The absolute (Abdiff = [D(max) Man - D (max)DVH]) and relative (Rediff[%] = 100 x ([D(max)Man-D(max)DVH])/D(max)DVH) maximal skin and rib dose differences between the manual selection method (D(max)Man) and the objective method (D(max)DVH) were measured for 50 balloon-based HDR (25 MammoSite and 25 Contura) patients. The average +/- standard deviation of maximal dose difference was 1.67% +/- 1.69% of the prescribed dose (PD). No statistical difference was observed between MammoSite and Contura patients for both Abdiff and Rediff[%] values. However, a statistically significant difference (p value skin dose difference for both Abdiff (2.30% +/- 1.71% vs 1.05% +/- 1.43%) and Rediff[%] (2.32% +/- 1.79% vs 1.21% +/- 1.41%). In general, rib has a more irregular contour and it is more proximally located to the balloon for 50 HDR patients. Due to the inverse square law factor, more dose difference was observed in higher dose range (D(max) > 90%) compared with lower dose range (D(max) skin and rib can determine the planner-independent maximal dose compared with the manual selection method. However, the difference was < 2% of PD, on average, if appropriate attention is paid to selecting a manual dose point in 3D planning CT images.

  16. In-Vivo High Dynamic Range Vector Flow Imaging

    DEFF Research Database (Denmark)

    Villagómez Hoyos, Carlos Armando; Stuart, Matthias Bo; Jensen, Jørgen Arendt

    2015-01-01

    Current vector flow systems are limited in their detectable range of blood flow velocities. Previous work on phantoms has shown that the velocity range can be extended using synthetic aperture directional beamforming combined with an adaptive multi-lag approach. This paper presents a first invivo...

  17. A review of nonstandardized applicators digitization in Nucletron™ HDR procedures.

    Science.gov (United States)

    Wang, Kelin; Ferenci, Michele S; de la Zerda, Alberto; Padgett, Kyle R; Bossart, Elizabeth L; Chao, Ming; Shao, Hua; Zhang, Mutain

    2017-09-01

    The major errors in HDR procedures were failures to enter the correct treatment distance, which could be caused by either entering wrong transmission lengths or imprecisely digitizing the dwelling positions. Most of those errors were not easily avoidable by enhancing the HDR management level because they were caused by implementations of nonstandardized applicators utilizing transmission tubes of different lengths in standard HDR procedures. We performed this comprehensive study to include all possible situations with different nonstandardized applicators that frequently occurred in HDR procedures, provide corresponding situations with standard applicator as comparisons, list all possible errors and in planning, clarify the confusions in offsets setting, and provide mathematical and quantitative solutions for each given scenarios. Training on HDR procedures with nonstandardized applicators are normally not included in most residential program for medical physics, thus this study could be meaningful in both clinical and educational purpose. At precision of 1 mm, our study could be used as the essential and practical reference for finding the correct treatment length as well as locating the accurate dwelling positions in any HDR procedure with nonstandardized applicators. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  18. High-dose-rate (HDR) brachytherapy for the treatment of benign obstructive endobronchial granulation tissue.

    Science.gov (United States)

    Madu, Chika N; Machuzak, Michael S; Sterman, Daniel H; Musani, Ali; Ahya, Vivek; McDonough, James; Metz, James M

    2006-12-01

    Severe airway obstruction can occur in the setting of benign granulation tissue forming at bronchial anastomotic sites after lung transplantation in up to 20% of patients. Many of these benign lesions respond to stent placement, laser ablation, or balloon bronchoplasty. However, in certain cases, proliferation of granulation tissue may persist despite all therapeutic attempts. This study describes a series of refractory patients treated with high-dose-rate (HDR) brachytherapy for benign proliferation of granulation tissue, causing airway compromise. Between April 2002 and June 2005, 5 patients with significant airway compromise from recurrent granulation tissue were treated with HDR brachytherapy. All patients had previously failed to maintain a patent airway despite multiple bronchoscopic interventions. Treatment was delivered using an HDR brachytherapy afterloader with (192)Ir. Dose prescription was to a depth of 1 cm. All patients were treated weekly, with total doses ranging from 10 Gy to 21 Gy in two to three fractions. The median follow-up was 12 months. All patients experienced a reduction in therapeutic bronchoscopic procedures after HDR brachytherapy compared with the pretreatment period. With the exception of possible radiation-induced bronchitis in 1 patient, there were no other treatment related complications. At the time of this report, 2 patients have died and the other 3 are alive with marked symptomatic improvement and reduced bronchoscopic procedures. High-dose-rate brachytherapy is an effective treatment for benign proliferation of granulation tissue causing airway obstruction. The early response to therapy is encouraging and further follow-up is necessary to determine long-term durability and late effects.

  19. An experimental MOSFET approach to characterize (192)Ir HDR source anisotropy.

    Science.gov (United States)

    Toye, W C; Das, K R; Todd, S P; Kenny, M B; Franich, R D; Johnston, P N

    2007-09-07

    The dose anisotropy around a (192)Ir HDR source in a water phantom has been measured using MOSFETs as relative dosimeters. In addition, modeling using the EGSnrc code has been performed to provide a complete dose distribution consistent with the MOSFET measurements. Doses around the Nucletron 'classic' (192)Ir HDR source were measured for a range of radial distances from 5 to 30 mm within a 40 x 30 x 30 cm(3) water phantom, using a TN-RD-50 MOSFET dosimetry system with an active area of 0.2 mm by 0.2 mm. For each successive measurement a linear stepper capable of movement in intervals of 0.0125 mm re-positioned the MOSFET at the required radial distance, while a rotational stepper enabled angular displacement of the source at intervals of 0.9 degrees . The source-dosimeter arrangement within the water phantom was modeled using the standardized cylindrical geometry of the DOSRZnrc user code. In general, the measured relative anisotropy at each radial distance from 5 mm to 30 mm is in good agreement with the EGSnrc simulations, benchmark Monte Carlo simulation and TLD measurements where they exist. The experimental approach employing a MOSFET detection system of small size, high spatial resolution and fast read out capability allowed a practical approach to the determination of dose anisotropy around a HDR source.

  20. Adaptive optics instrument for long-range imaging. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Crawford, T.M.

    1998-06-01

    The science and history of imaging through a turbulent atmosphere is reviewed in detail. Traditional methods for reducing the effects of turbulence are presented. A simplified method for turbulence reduction called the Sheared Coherent Interferometric Photography (SCIP) method is presented. Implementation of SCIP is discussed along with experimental results. Limitations in the use of this method are discussed along with recommendations for future improvements.

  1. Evaluation of water-mimicking solid phantom materials for use in HDR and LDR brachytherapy dosimetry

    Science.gov (United States)

    Schoenfeld, Andreas A.; Thieben, Maike; Harder, Dietrich; Poppe, Björn; Chofor, Ndimofor

    2017-12-01

    In modern HDR or LDR brachytherapy with photon emitters, fast checks of the dose profiles generated in water or a water-equivalent phantom have to be available in the interest of patient safety. However, the commercially available brachytherapy photon sources cover a wide range of photon emission spectra, and the range of the in-phantom photon spectrum is further widened by Compton scattering, so that the achievement of water-mimicking properties of such phantoms involves high requirements on their atomic composition. In order to classify the degree of water equivalence of the numerous commercially available solid water-mimicking phantom materials and the energy ranges of their applicability, the radial profiles of the absorbed dose to water, D w, have been calculated using Monte Carlo simulations in these materials and in water phantoms of the same dimensions. This study includes the HDR therapy sources Nucletron Flexisource Co-60 HDR (60Co), Eckert und Ziegler BEBIG GmbH CSM-11 (137Cs), Implant Sciences Corporation HDR Yb-169 Source 4140 (169Yb) as well as the LDR therapy sources IsoRay Inc. Proxcelan CS-1 (131Cs), IsoAid Advantage I-125 IAI-125A (125I), and IsoAid Advantage Pd-103 IAPd-103A (103Pd). Thereby our previous comparison between phantom materials and water surrounding a Varian GammaMed Plus HDR therapy 192Ir source (Schoenfeld et al 2015) has been complemented. Simulations were performed in cylindrical phantoms consisting of either water or the materials RW1, RW3, Solid Water, HE Solid Water, Virtual Water, Plastic Water DT, Plastic Water LR, Original Plastic Water (2015), Plastic Water (1995), Blue Water, polyethylene, polystyrene and PMMA. While for 192Ir, 137Cs and 60Co most phantom materials can be regarded as water equivalent, for 169Yb the materials Plastic Water LR, Plastic Water DT and RW1 appear as water equivalent. For the low-energy sources 106Pd, 131Cs and 125I, only Plastic Water LR can be classified as water equivalent.

  2. SU-F-T-55: Reproducibility of Interstitial HDR Brachytherapy Plans

    Energy Technology Data Exchange (ETDEWEB)

    Lee, S; Ellis, R; Traughber, B; Podder, T [University Hospitals Case Medical Center, Cleveland, OH (United States)

    2016-06-15

    Purpose: Treating gynecological cancers with interstitial high-dose-rate (HDR) brachytherapy requires precise reconstruction of catheter positions to obtain accurate dosimetric plans. In this study, we investigated the degree of reproducibility of dosimetric plans for Syed HDR brachytherapy. Methods: We randomly selected five patients having cervix-vaginal cancer who were recently treated in our clinic with interstitial HDR brachytherapy with a prescription dose of 25–30 Gy in five fractions. Interstitial needles/catheters were placed under fluoroscopic guidance and intra-operative 3T MRI scan was performed to confirm the desired catheter placement for adequate target volume coverage. A CT scan was performed and fused with the MRI for delineating high-risk CTV (HR-CTV), intermediate-risk CTV (IR-CTV) and OARs. HDR treatment plans were generated using Oncentra planning software. A single plan was used for all five fractions of treatment for each patient. For this study, we took the original clinical plan and removed all the reconstructed catheters from the plan keeping the original contours unchanged. Then, we manually reconstructed all the catheters and entered the same dwell time from the first original clinical plan. The dosimetric parameters studied were: D90 for HR-CTV and IR-CV, and D2cc for bladder, rectum, sigmoid and bowel. Results: The mean of absolute differences in dosimetric coverage (D90) were (range): 1.3% (1.0–2.0%) and 2.0% (0.9–3.6%) for HR-CTV and IR-CTV, respectively. In case of OARs, the mean of absolute variations in D2cc were (range): 4.7% (0.7–8.9%) for bladder, 1.60% (0.3–3.2%) for rectum, 1.6% (0–3.9%) for sigmoid, and 1.8% (0–5.1%) for bowel. Conclusion: Overall, the reproducibility of interstitial HDR plans was within clinically acceptable limit. Observed maximum variation in D2cc for bladder. If number of catchers and dwell points were relatively low or any one catheter was heavily loaded, then reproducibility of the plan

  3. Lookup Table Hough Transform for Real Time Range Image Segmentation and Featureless Co-Registration

    NARCIS (Netherlands)

    Gorte, B.G.H.; Sithole, G.

    2012-01-01

    The paper addresses range image segmentation, particularly of data recorded by range cameras, such as the Microsoft Kinect and the Mesa Swissranger SR4000. These devices record range images at video frame rates and allow for acqui-sition of 3-dimensional measurement sequences that can be used for 3D

  4. Balloon-based adjuvant radiotherapy in breast cancer: comparison between (99m)Tc and HDR (192)Ir.

    Science.gov (United States)

    de Campos, Tarcísio Passos Ribeiro; de Lima, Carla Flavia; Cuperschmid, Ethel Mizrahy

    2016-01-01

    To perform a comparative dosimetric analysis, based on computer simulations, of temporary balloon implants with (99m)Tc and balloon brachytherapy with high-dose-rate (HDR) (192)Ir, as boosts to radiotherapy. We hypothesized that the two techniques would produce equivalent doses under pre-established conditions of activity and exposure time. Simulations of implants with (99m)Tc-filled and HDR (192)Ir-filled balloons were performed with the Siscodes/MCNP5, modeling in voxels a magnetic resonance imaging set related to a young female. Spatial dose rate distributions were determined. In the dosimetric analysis of the protocols, the exposure time and the level of activity required were specified. The (99m)Tc balloon presented a weighted dose rate in the tumor bed of 0.428 cGy.h(-1).mCi(-1) and 0.190 cGyh(-1).mCi(-1) at the balloon surface and at 8-10 mm from the surface, respectively, compared with 0.499 and 0.150 cGyh(-1).mCi(-1), respectively, for the HDR (192)Ir balloon. An exposure time of 24 hours was required for the (99m)Tc balloon to produce a boost of 10.14 Gy with 1.0 Ci, whereas only 24 minutes with 10.0 Ci segments were required for the HDR (192)Ir balloon to produce a boost of 5.14 Gy at the same reference point, or 10.28 Gy in two 24-minutes fractions. Temporary (99m)Tc balloon implantation is an attractive option for adjuvant radiotherapy in breast cancer, because of its availability, economic viability, and similar dosimetry in comparison with the use of HDR (192)Ir balloon implantation, which is the current standard in clinical practice.

  5. Balloon-based adjuvant radiotherapy in breast cancer: comparison between {sup 99m}Tc and HDR {sup 192}Ir

    Energy Technology Data Exchange (ETDEWEB)

    Campos, Tarcisio Passos Ribeiro de; Lima, Carla Flavia de; Cuperschmid, Ethel Mizrahy, E-mail: tprcampos@pq.cnpq.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil)

    2016-03-15

    Objective: To perform a comparative dosimetric analysis, based on computer simulations, of temporary balloon implants with {sup 99m}Tc and balloon brachytherapy with high-dose-rate (HDR) {sup 192}Ir, as boosts to radiotherapy. We hypothesized that the two techniques would produce equivalent doses under pre-established conditions of activity and exposure time. Materials and methods: simulations of implants with {sup 99m}Tc-filled and HDR {sup 192}Ir-filled balloons were performed with the Siscodes/MCNP5, modeling in voxels a magnetic resonance imaging set related to a young female. Spatial dose rate distributions were determined. In the dosimetric analysis of the protocols, the exposure time and the level of activity required were specified. Results: the {sup 99m}Tc balloon presented a weighted dose rate in the tumor bed of 0.428 cGy.h{sup -1}.mCi{sup -1} and 0.190 cGyh{sup -1} at the balloon surface and at 8-10 mm from the surface, respectively, compared with 0.499 and 0.150 cGyh{sup -1}.mCi{sup -1}, respectively, for the HDR {sup 192}Ir balloon. An exposure time of 24 hours was required for the {sup 99m}Tc balloon to produce a boost of 10.14 Gy with 1.0 Ci, whereas only 24 minutes with 10.0 Ci segments were required for the HDR {sup 192}Ir balloon to produce a boost of 5.14 Gy at the same reference point, or 10.28 Gy in two 24-minutes fractions. Conclusion: temporary {sup 99m}Tc balloon implantation is an attractive option for adjuvant radiotherapy in breast cancer, because of its availability, economic viability, and similar dosimetry in comparison with the use of HDR {sup 192}Ir balloon implantation, which is the current standard in clinical practice. (author)

  6. Design and implementation of range-gated underwater laser imaging system

    Science.gov (United States)

    Ge, Wei-long; Zhang, Xiao-hui

    2014-02-01

    A range-gated underwater laser imaging system is designed and implemented in this article, which is made up of laser illumination subsystem, photoelectric imaging subsystem and control subsystem. The experiment of underwater target drone detection has been done, the target of distance 40m far from the range-gated underwater laser imaging system can be imaged in the pool which water attenuation coefficient is 0.159m-1. Experimental results show that the range-gated underwater laser imaging system can detect underwater objects effectively.

  7. Ahsa1 and Hsp90 activity confers more severe craniofacial phenotypes in a zebrafish model of hypoparathyroidism, sensorineural deafness and renal dysplasia (HDR

    Directory of Open Access Journals (Sweden)

    Kelly Sheehan-Rooney

    2013-09-01

    The severity of most human birth defects is highly variable. Our ability to diagnose, treat and prevent defects relies on our understanding of this variability. Mutation of the transcription factor GATA3 in humans causes the highly variable hypoparathyroidism, sensorineural deafness and renal dysplasia (HDR syndrome. Although named for a triad of defects, individuals with HDR can also exhibit craniofacial defects. Through a forward genetic screen for craniofacial mutants, we isolated a zebrafish mutant in which the first cysteine of the second zinc finger of Gata3 is mutated. Because mutation of the homologous cysteine causes HDR in humans, these zebrafish mutants could be a quick and effective animal model for understanding the role of gata3 in the HDR disease spectrum. We demonstrate that, unexpectedly, the chaperone proteins Ahsa1 and Hsp90 promote severe craniofacial phenotypes in our zebrafish model of HDR syndrome. The strengths of the zebrafish system, including rapid development, genetic tractability and live imaging, make this an important model for variability.

  8. Laser range scanning for image-guided neurosurgery: investigation of image-to-physical space registrations.

    Science.gov (United States)

    Cao, Aize; Thompson, R C; Dumpuri, P; Dawant, B M; Galloway, R L; Ding, S; Miga, M I

    2008-04-01

    In this article a comprehensive set of registration methods is utilized to provide image-to-physical space registration for image-guided neurosurgery in a clinical study. Central to all methods is the use of textured point clouds as provided by laser range scanning technology. The objective is to perform a systematic comparison of registration methods that include both extracranial (skin marker point-based registration (PBR), and face-based surface registration) and intracranial methods (feature PBR, cortical vessel-contour registration, a combined geometry/intensity surface registration method, and a constrained form of that method to improve robustness). The platform facilitates the selection of discrete soft-tissue landmarks that appear on the patient's intraoperative cortical surface and the preoperative gadolinium-enhanced magnetic resonance (MR) image volume, i.e., true corresponding novel targets. In an 11 patient study, data were taken to allow statistical comparison among registration methods within the context of registration error. The results indicate that intraoperative face-based surface registration is statistically equivalent to traditional skin marker registration. The four intracranial registration methods were investigated and the results demonstrated a target registration error of 1.6 +/- 0.5 mm, 1.7 +/- 0.5 mm, 3.9 +/- 3.4 mm, and 2.0 +/- 0.9 mm, for feature PBR, cortical vessel-contour registration, unconstrained geometric/intensity registration, and constrained geometric/intensity registration, respectively. When analyzing the results on a per case basis, the constrained geometric/intensity registration performed best, followed by feature PBR, and finally cortical vessel-contour registration. Interestingly, the best target registration errors are similar to targeting errors reported using bone-implanted markers within the context of rigid targets. The experience in this study as with others is that brain shift can compromise extracranial

  9. FVP10: enhancements of VPX for SDR/HDR applications

    Science.gov (United States)

    Topiwala, Pankaj; Dai, Wei; Krishnan, Madhu

    2016-09-01

    This paper describes a study to investigate possible ways to improve the VPX codecs in the context of both 8-bit SDR video and 10-bit HDR video content, for two types of applications: streaming and high quality (near lossless) coding for content contribution editing. For SDR content, the following tools are investigated: (a) lapped biorthogonal transforms for near lossless applications; and (b) optimized resampling filter pairs for adaptive resolution coding in streaming applications. For HDR content, a data adaptive grading technique in conjunction with the VP9/VP10 encoder is studied. Both the objective metrics (measured using BD rate) and informal subjective visual quality assessments are recorded. It is asserted that useful improvements are possible in each of these categories. In particular, substantial value is offered in the coding of HDR content, and especially in creating a coding scheme offering backwards compatibility with SDR.

  10. Improved Feature Detection in Fused Intensity-Range Images with Complex SIFT (ℂSIFT

    Directory of Open Access Journals (Sweden)

    Boris Jutzi

    2011-09-01

    Full Text Available The real and imaginary parts are proposed as an alternative to the usual Polar representation of complex-valued images. It is proven that the transformation from Polar to Cartesian representation contributes to decreased mutual information, and hence to greater distinctiveness. The Complex Scale-Invariant Feature Transform (ℂSIFT detects distinctive features in complex-valued images. An evaluation method for estimating the uniformity of feature distributions in complex-valued images derived from intensity-range images is proposed. In order to experimentally evaluate the proposed methodology on intensity-range images, three different kinds of active sensing systems were used: Range Imaging, Laser Scanning, and Structured Light Projection devices (PMD CamCube 2.0, Z+F IMAGER 5003, Microsoft Kinect.

  11. Study of CT-based positron range correction in high resolution 3D PET imaging

    Energy Technology Data Exchange (ETDEWEB)

    Cal-Gonzalez, J., E-mail: jacobo@nuclear.fis.ucm.es [Grupo de Fisica Nuclear, Dpto. Fisica Atomica, Molecular y Nuclear, Universidad Complutense de Madrid (Spain); Herraiz, J.L. [Grupo de Fisica Nuclear, Dpto. Fisica Atomica, Molecular y Nuclear, Universidad Complutense de Madrid (Spain); Espana, S. [Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School, Boston, MA (United States); Vicente, E. [Grupo de Fisica Nuclear, Dpto. Fisica Atomica, Molecular y Nuclear, Universidad Complutense de Madrid (Spain); Instituto de Estructura de la Materia, Consejo Superior de Investigaciones Cientificas (CSIC), Madrid (Spain); Herranz, E. [Grupo de Fisica Nuclear, Dpto. Fisica Atomica, Molecular y Nuclear, Universidad Complutense de Madrid (Spain); Desco, M. [Unidad de Medicina y Cirugia Experimental, Hospital General Universitario Gregorio Maranon, Madrid (Spain); Vaquero, J.J. [Dpto. de Bioingenieria e Ingenieria Espacial, Universidad Carlos III, Madrid (Spain); Udias, J.M. [Grupo de Fisica Nuclear, Dpto. Fisica Atomica, Molecular y Nuclear, Universidad Complutense de Madrid (Spain)

    2011-08-21

    Positron range limits the spatial resolution of PET images and has a different effect for different isotopes and positron propagation materials. Therefore it is important to consider it during image reconstruction, in order to obtain optimal image quality. Positron range distributions for most common isotopes used in PET in different materials were computed using the Monte Carlo simulations with PeneloPET. The range profiles were introduced into the 3D OSEM image reconstruction software FIRST and employed to blur the image either in the forward projection or in the forward and backward projection. The blurring introduced takes into account the different materials in which the positron propagates. Information on these materials may be obtained, for instance, from a segmentation of a CT image. The results of introducing positron blurring in both forward and backward projection operations was compared to using it only during forward projection. Further, the effect of different shapes of positron range profile in the quality of the reconstructed images with positron range correction was studied. For high positron energy isotopes, the reconstructed images show significant improvement in spatial resolution when positron range is taken into account during reconstruction, compared to reconstructions without positron range modeling.

  12. Palliative interstitial HDR brachytherapy for recurrent rectal cancer. Implantation techniques and results

    Energy Technology Data Exchange (ETDEWEB)

    Kolotas, C. [Dept. of Radiation Oncology, Offenbach Hospital, Offenbach (Germany); Dept. of Radio-Oncology, Univ. of Bern, Inselspital, Bern (Switzerland); Roeddiger, S.; Martin, T.; Tselis, N.; Baltas, D.; Zamboglou, N. [Dept. of Radiation Oncology, Offenbach Hospital, Offenbach (Germany); Strassmann, G. [Dept. of Radiotherapy, Univ. Hospital, Philipps Univ., Marburg (Germany); Aebersold, D.M. [Dept. of Radio-Oncology, Univ. of Bern, Inselspital, Bern (Switzerland)

    2003-07-01

    Purpose: To report the methods and clinical results of CT-based interstitial high-dose-rate (HDR) brachytherapy procedures for the palliative treatment of recurrent rectal cancer. Patients and Methods: A total of 44 brachytherapy implants were performed in 38 patients. CT-guided catheter implants were performed in 34 patients under local anesthesia and sedation, and four patients were implanted intraoperatively. Of 40 CT-guided implants, 20 were done using metallic needles introduced via the sacrum and 20 were transperineal implants of plastic tubes in the presacral region. Postimplant CT scans were used for three-dimensional (3-D) conformal brachytherapy planning. Patients implanted with metallic needles were given a single fraction of 10-15 Gy using HDR {sup 192}Ir, and those who received transperineal implants of plastic catheters were given fractionated brachytherapy, 5 Gy twice daily to a total dose of 30-40 Gy. The median tumor volume was 225 cm{sup 3} with a range of 41-2,103 cm{sup 3}. Results: After a median follow-up of 23.4 months, a total of 13/38 patients were alive. The median postbrachytherapy survival was 15 months with 18 of the 25 deaths due to distant metastases. Tumor response was as follows: 6/38 partial remission, 28/38 stable disease, and 4/38 local progression. A planning target volume (PTV) coverage > 85% was achieved in 42/44 implants. The treatment was well tolerated, and no acute complications were observed. One patient developed a fistula after 8 months. Pain relief was recorded in 34 patients (89.5%), and the median duration of this palliative effect was 5 months with a range of 1-13 months. Conclusions: Interstitial HDR brachytherapy is a valuable tool for the delivery of high doses and achieves effective palliation in recurrent rectal carcinoma. (orig.)

  13. Salvage prostate HDR brachytherapy combined with interstitial hyperthermia for local recurrence after radiation therapy failure

    Energy Technology Data Exchange (ETDEWEB)

    Kukielka, A.M.; Hetnal, M.; Dabrowski, T.; Walasek, T.; Brandys, P.; Reinfuss, M. [Centre of Oncology, M. Sklodowska - Curie Institute, Krakow Branch, Department of Radiotherapy, Krakow (Poland); Nahajowski, D.; Kudzia, R.; Dybek, D. [Centre of Oncology, M. Sklodowska - Curie Institute, Krakow Branch, Department of Medical Physics, Department of Radiotherapy, Krakow (Poland)

    2014-02-15

    The aim of the present retrospective study is to evaluate toxicity and early clinical outcomes of interstitial hyperthermia (IHT) combined with high-dose rate (HDR) brachytherapy as a salvage treatment in patients with biopsy-confirmed local recurrence of prostate cancer after previous external beam radiotherapy. Between September 2008 and March 2013, 25 patients with local recurrence of previously irradiated prostate cancer were treated. The main eligibility criteria for salvage prostate HDR brachytherapy combined with interstitial hyperthermia were biopsy confirmed local recurrence and absence of nodal and distant metastases. All patients were treated with a dose of 30 Gy in 3 fractions at 21-day intervals. We performed 62 hyperthermia procedures out of 75 planned (83 %). The aim of the hyperthermia treatment was to heat the prostate to 41-43 C for 60 min. Toxicity for the organs of the genitourinary system and rectum was assessed according to the Common Terminology Criteria for Adverse Events (CTCAE, v. 4.03). Determination of subsequent biochemical failure was based on the Phoenix definition (nadir + 2 ng/ml). The median age was 71 years (range 62-83 years), the median initial PSA level was 16.3 ng/ml (range 6.37-64 ng/ml), and the median salvage PSA level was 2.8 ng/ml (1.044-25.346 ng/ml). The median follow-up was 13 months (range 4-48 months). The combination of HDR brachytherapy and IHT was well tolerated. The most frequent complications were nocturia, weak urine stream, urinary frequency, hematuria, and urgency. Grade 2 rectal hemorrhage was observed in 1 patient. No grade 3 or higher complications were observed. The 2-year Kaplan-Meier estimate of biochemical control after salvage treatment was 74 %. The PSA in 20 patients decreased below the presalvage level, while 11 patients achieved a PSA nadir < 0.5 ng/ml. All patients are still alive. Of the 7 patients who experienced biochemical failure, bone metastases were found in 2 patients. IHT in combination

  14. Study on enhancing dynamic range of CCD imaging based on digital micro-mirror device

    Science.gov (United States)

    Zhou, Wang

    2009-05-01

    DMD used as SLM modulation area array CCD design is proposed in the paper. It can Solve a problem in exposing high-contrast scenes by ordinary CCD camera, with images appearing over-exposure or under exposure, bringing a loss of the details of the photo. The method adoptes a forecast imaging scene, CCD is purposely designed by way of more exposure regions and exposure times. Through modulation function of DMD micro-mirror, CCD is exposed with sub-region and time-sharing, at the same time a purposely designed structure of image data enhances the area CCD dynamic range. Experiments shows: This method not only improves visible quality of an image and clear details in the backlighting or highlight, but also enhances the dynamic range of image data. The high-quality image and high dynamic range data are real-time captured, the "fused" software is no longer required.

  15. The application of camera calibration in range-gated 3D imaging technology

    Science.gov (United States)

    Liu, Xiao-quan; Wang, Xian-wei; Zhou, Yan

    2013-09-01

    Range-gated laser imaging technology was proposed in 1966 by LF Gillespiethe in U.S. Army Night Vision Laboratory(NVL). Using pulse laser and intensified charge-coupled device(ICCD) as light source and detector respectively, range-gated laser imaging technology can realize space-slice imaging while restraining the atmospheric backs-catter, and in turn detect the target effectively, by controlling the delay between the laser pulse and strobe. Owing to the constraints of the development of key components such as narrow pulse laser and gated imaging devices, the research has been progressed slowly in the next few decades. Until the beginning of this century, as the hardware technology continues to mature, this technology has developed rapidly in fields such as night vision, underwater imaging, biomedical imaging, three-dimensional imaging, especially range-gated three-dimensional(3-D) laser imaging field purposing of access to target spatial information. 3-D reconstruction is the processing of restoration of 3-D objects visible surface geometric structure from three-dimensional(2-D) image. Range-gated laser imaging technology can achieve gated imaging of slice space to form a slice image, and in turn provide the distance information corresponding to the slice image. But to inverse the information of 3-D space, we need to obtain the imaging visual field of system, that is, the focal length of the system. Then based on the distance information of the space slice, the spatial information of each unit space corresponding to each pixel can be inversed. Camera calibration is an indispensable step in 3-D reconstruction, including analysis of the internal structure of camera parameters and the external parameters . In order to meet the technical requirements of the range-gated 3-D imaging, this paper intends to study the calibration of the zoom lens system. After summarizing the camera calibration technique comprehensively, a classic calibration method based on line is

  16. Calculation of the Transit Dose in HDR Brachytherapy Based on ...

    African Journals Online (AJOL)

    The Monte Carlo method, which is the gold standard for accurate dose calculations in radiotherapy, was used to obtain the transit doses around a high dose rate (HDR) brachytherapy implant with thirteen dwell points. The midpoints of each of the inter-dwell separations, of step size 0.25 cm, were representative of the ...

  17. Coexistence Mechanism for Colocated HDR/LDR WPANs Air Interfaces

    Directory of Open Access Journals (Sweden)

    Prasad Ramjee

    2010-01-01

    Full Text Available This paper addresses the issues of interference management among Low Data Rate (LDR and High Data Rate (HDR WPAN air interfaces that are located in close-proximity (up to 10 cm and eventually on the same multimode device. After showing the noticeable performance degradation in terms of Bit Error Rate (BER and goodput due to the out-of-band interference of an HDR air interface over an LDR air interface, the paper presents a novel coexistence mechanism, named Alternating Wireless Activity (AWA, which is shown to greatly improve the performance in terms of goodput of the most interference vulnerable air interface (i.e., the LDR air interface. The main difference of the proposed mechanism with respect to other collaborative mechanisms based on time-scheduling is that it synchronizes the transmission of the LDR and HDR WPANs at the superframe level instead of packet level. Advantages and limitations of this choice are presented in the paper. Furthermore the functionalities of the AWA mechanism are positioned in a common protocol layer over the Medium Access Control (MAC sublayers of the HDR and LDR devices and it can be used with any standard whose MAC is based on a superframe structure.

  18. Error Analysis of non-TLD HDR Brachytherapy Dosimetric Techniques

    Science.gov (United States)

    Amoush, Ahmad

    , and 4cm, 5cm, 6cm, and 7cm, respectively. The Nucletron Freiburg flap applicator is used with the Nucletron remote afterloader HDR machine to deliver dose to surface cancers. Dosimetric data for the Nucletron 192Ir source were generated using Monte Carlo simulation and compared with the published data. Two dimensional dosimetric data were calculated at two source positions; at the center of the sphere of the applicator and between two adjacent spheres. Unlike the TPS dose algorithm, The Monte Carlo code developed for this research accounts for the applicator material, secondary electrons and delta particles, and the air gap between the skin and the applicator. *Standard Imaging, Inc., Middleton, Wisconsin USA † OneDose MOSFET, Sicel Technologies, Morrisville NC ‡ Los Alamos National Laboratory, NM USA

  19. SU-E-T-169: Characterization of Pacemaker/ICD Dose in SAVI HDR Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Kalavagunta, C; Lasio, G; Yi, B; Zhou, J; Lin, M [Univ. of Maryland School Of Medicine, Baltimore, MD (United States)

    2015-06-15

    Purpose: It is important to estimate dose to pacemaker (PM)/Implantable Cardioverter Defibrillator (ICD) before undertaking Accelerated Partial Breast Treatment using High Dose Rate (HDR) brachytherapy. Kim et al. have reported HDR PM/ICD dose using a single-source balloon applicator. To the authors knowledge, there have so far not been any published PM/ICD dosimetry literature for the Strut Adjusted Volume Implant (SAVI, Cianna Medical, Aliso Viejo, CA). This study aims to fill this gap by generating a dose look up table (LUT) to predict maximum dose to the PM/ICD in SAVI HDR brachytherapy. Methods: CT scans for 3D dosimetric planning were acquired for four SAVI applicators (6−1-mini, 6−1, 8−1 and 10−1) expanded to their maximum diameter in air. The CT datasets were imported into the Elekta Oncentra TPS for planning and each applicator was digitized in a multiplanar reconstruction window. A dose of 340 cGy was prescribed to the surface of a 1 cm expansion of the SAVI applicator cavity. Cartesian coordinates of the digitized applicator were determined in the treatment leading to the generation of a dose distribution and corresponding distance-dose prediction look up table (LUT) for distances from 2 to 15 cm (6-mini) and 2 to 20 cm (10–1).The deviation between the LUT doses and the dose to the cardiac device in a clinical case was evaluated. Results: Distance-dose look up table were compared to clinical SAVI plan and the discrepancy between the max dose predicted by the LUT and the clinical plan was found to be in the range (−0.44%, 0.74%) of the prescription dose. Conclusion: The distance-dose look up tables for SAVI applicators can be used to estimate the maximum dose to the ICD/PM, with a potential usefulness for quick assessment of dose to the cardiac device prior to applicator placement.

  20. Electro-optic modulation methods in range-gated active imaging.

    Science.gov (United States)

    Chen, Zhen; Liu, Bo; Liu, Enhai; Peng, Zhangxian

    2016-01-20

    A time-resolved imaging method based on electro-optic modulation is proposed in this paper. To implement range resolution, two kinds of polarization-modulated methods are designed, and high spatial and range resolution can be achieved by the active imaging system. In the system, with polarization beam splitting the incident light is split into two parts, one of which is modulated with cos(2) function and the other is modulated with sin(2) function. Afterward, a depth map can be obtained from two simultaneously received images by dual electron multiplying charge-coupled devices. Furthermore, an intensity image can also be obtained from the two images. Comparisons of the two polarization-modulated methods indicate that range accuracy will be promoted when the polarized light is modulated before beam splitting.

  1. SU-F-T-11: Scintillator Based Quality Assurance Device for HDR Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Jozsef, G [New York University Medical Center, New York, NY (United States)

    2016-06-15

    Purpose: To build a test device for HDR afterloaders capable of checking source positions, times at positions and estimate the activity of the source. Methods: A catheter is taped on a plastic scintillation sheet. When a source travels through the catheter, the scintillator sheet lights up around the source. The sheet is monitored with a video camera, and records the movement of the light spot. The center of the spot on each image on the video provides the source location, and the time stamps of the images can provide the dwell time the source spend in each location. Finally, the brightness of the light spot is related to the activity of the source. A code was developed for noise removal, calibrate the scale of the image to centimeters, eliminate the distortion caused by the oblique view angle, identifying the boundaries of the light spot, transforming the image into binary and detect and calculate the source motion, positions and times. The images are much less noisy if the camera is shielded. That requires that the light spot is monitored in a mirror, rather than directly. The whole assembly is covered from external light and has a size of approximately 17×35×25cm (H×L×W) Results: A cheap camera in BW mode proved to be sufficient with a plastic scintillator sheet. The best images were resulted by a 3mm thick sheet with ZnS:Ag surface coating. The shielding of the camera decreased the noise, but could not eliminate it. A test run even in noisy condition resulted in approximately 1 mm and 1 sec difference from the planned positions and dwell times. Activity tests are in progress. Conclusion: The proposed method is feasible. It might simplify the monthly QA process of HDR Brachytherapy units.

  2. The CAOS camera platform: ushering in a paradigm change in extreme dynamic range imager design

    Science.gov (United States)

    Riza, Nabeel A.

    2017-02-01

    Multi-pixel imaging devices such as CCD, CMOS and Focal Plane Array (FPA) photo-sensors dominate the imaging world. These Photo-Detector Array (PDA) devices certainly have their merits including increasingly high pixel counts and shrinking pixel sizes, nevertheless, they are also being hampered by limitations in instantaneous dynamic range, inter-pixel crosstalk, quantum full well capacity, signal-to-noise ratio, sensitivity, spectral flexibility, and in some cases, imager response time. Recently invented is the Coded Access Optical Sensor (CAOS) Camera platform that works in unison with current Photo-Detector Array (PDA) technology to counter fundamental limitations of PDA-based imagers while providing high enough imaging spatial resolution and pixel counts. Using for example the Texas Instruments (TI) Digital Micromirror Device (DMD) to engineer the CAOS camera platform, ushered in is a paradigm change in advanced imager design, particularly for extreme dynamic range applications.

  3. PROVE GOES-8 Images of Jornada Experimental Range, New Mexico, 1997

    Data.gov (United States)

    National Aeronautics and Space Administration — As part of the Prototype Validation Experiment (PROVE) at the Jornada Experimental Range, GOES-8 images were collected every 30 minutes for 15 days overlapping the...

  4. Fusing range and intensity images for generating dense models of three-dimensional environments

    DEFF Research Database (Denmark)

    Ellekilde, Lars-Peter; Miró, Jaime Valls; Dissanayake., Gamini

    This paper presents a novel strategy for the construction of dense three-dimensional environment models by combining images from a conventional camera and a range imager. Ro- bust data association is ?rst accomplished by exploiting the Scale Invariant Feature Transformation (SIFT) technique on th...

  5. Fast Hue and Range Preserving Histogram: Specification: Theory and New Algorithms for Color Image Enhancement.

    Science.gov (United States)

    Nikolova, Mila; Steidl, Gabriele

    2014-07-16

    Color image enhancement is a complex and challenging task in digital imaging with abundant applications. Preserving the hue of the input image is crucial in a wide range of situations. We propose simple image enhancement algorithms which conserve the hue and preserve the range (gamut) of the R, G, B channels in an optimal way. In our setup, the intensity input image is transformed into a target intensity image whose histogram matches a specified, well-behaved histogram. We derive a new color assignment methodology where the resulting enhanced image fits the target intensity image. We analyse the obtained algorithms in terms of chromaticity improvement and compare them with the unique and quite popular histogram based hue and range preserving algorithm of Naik and Murthy. Numerical tests confirm our theoretical results and show that our algorithms perform much better than the Naik-Murthy algorithm. In spite of their simplicity, they compete with well-established alternative methods for images where hue-preservation is desired.

  6. A study on the dose distributions in various materials from an Ir-192 HDR brachytherapy source.

    Directory of Open Access Journals (Sweden)

    Shih-Ming Hsu

    Full Text Available Dose distributions of (192Ir HDR brachytherapy in phantoms simulating water, bone, lung tissue, water-lung and bone-lung interfaces using the Monte Carlo codes EGS4, FLUKA and MCNP4C are reported. Experiments were designed to gather point dose measurements to verify the Monte Carlo results using Gafchromic film, radiophotoluminescent glass dosimeter, solid water, bone, and lung phantom. The results for radial dose functions and anisotropy functions in solid water phantom were consistent with previously reported data (Williamson and Li. The radial dose functions in bone were affected more by depth than those in water. Dose differences between homogeneous solid water phantoms and solid water-lung interfaces ranged from 0.6% to 14.4%. The range between homogeneous bone phantoms and bone-lung interfaces was 4.1% to 15.7%. These results support the understanding in dose distribution differences in water, bone, lung, and their interfaces. Our conclusion is that clinical parameters did not provide dose calculation accuracy for different materials, thus suggesting that dose calculation of HDR treatment planning systems should take into account material density to improve overall treatment quality.

  7. Luminescence imaging of water during proton-beam irradiation for range estimation

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Seiichi, E-mail: s-yama@met.nagoya-u.ac.jp; Okumura, Satoshi; Komori, Masataka [Radiological and Medical Laboratory Sciences, Nagoya University Graduate School of Medicine, Nagoya 461-8673 (Japan); Toshito, Toshiyuki [Department of Proton Therapy Physics, Nagoya Proton Therapy Center, Nagoya City West Medical Center, Nagoya 462-8508 (Japan)

    2015-11-15

    Purpose: Proton therapy has the ability to selectively deliver a dose to the target tumor, so the dose distribution should be accurately measured by a precise and efficient method. The authors found that luminescence was emitted from water during proton irradiation and conjectured that this phenomenon could be used for estimating the dose distribution. Methods: To achieve more accurate dose distribution, the authors set water phantoms on a table with a spot scanning proton therapy system and measured the luminescence images of these phantoms with a high-sensitivity, cooled charge coupled device camera during proton-beam irradiation. The authors imaged the phantoms of pure water, fluorescein solution, and an acrylic block. Results: The luminescence images of water phantoms taken during proton-beam irradiation showed clear Bragg peaks, and the measured proton ranges from the images were almost the same as those obtained with an ionization chamber. Furthermore, the image of the pure-water phantom showed almost the same distribution as the tap-water phantom, indicating that the luminescence image was not related to impurities in the water. The luminescence image of the fluorescein solution had ∼3 times higher intensity than water, with the same proton range as that of water. The luminescence image of the acrylic phantom had a 14.5% shorter proton range than that of water; the proton range in the acrylic phantom generally matched the calculated value. The luminescence images of the tap-water phantom during proton irradiation could be obtained in less than 2 s. Conclusions: Luminescence imaging during proton-beam irradiation is promising as an effective method for range estimation in proton therapy.

  8. Luminescence imaging of water during carbon-ion irradiation for range estimation

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Seiichi, E-mail: s-yama@met.nagoya-u.ac.jp; Komori, Masataka; Koyama, Shuji; Morishita, Yuki; Sekihara, Eri [Radiological and Medical Laboratory Sciences, Nagoya University Graduate School of Medicine, Higashi-ku, Nagoya, Aichi 461-8673 (Japan); Akagi, Takashi; Yamashita, Tomohiro [Hygo Ion Beam Medical Center, Hyogo 679-5165 (Japan); Toshito, Toshiyuki [Department of Proton Therapy Physics, Nagoya Proton Therapy Center, Nagoya City West Medical Center, Aichi 462-8508 (Japan)

    2016-05-15

    Purpose: The authors previously reported successful luminescence imaging of water during proton irradiation and its application to range estimation. However, since the feasibility of this approach for carbon-ion irradiation remained unclear, the authors conducted luminescence imaging during carbon-ion irradiation and estimated the ranges. Methods: The authors placed a pure-water phantom on the patient couch of a carbon-ion therapy system and measured the luminescence images with a high-sensitivity, cooled charge-coupled device camera during carbon-ion irradiation. The authors also carried out imaging of three types of phantoms (tap-water, an acrylic block, and a plastic scintillator) and compared their intensities and distributions with those of a phantom containing pure-water. Results: The luminescence images of pure-water phantoms during carbon-ion irradiation showed clear Bragg peaks, and the measured carbon-ion ranges from the images were almost the same as those obtained by simulation. The image of the tap-water phantom showed almost the same distribution as that of the pure-water phantom. The acrylic block phantom’s luminescence image produced seven times higher luminescence and had a 13% shorter range than that of the water phantoms; the range with the acrylic phantom generally matched the calculated value. The plastic scintillator showed ∼15 000 times higher light than that of water. Conclusions: Luminescence imaging during carbon-ion irradiation of water is not only possible but also a promising method for range estimation in carbon-ion therapy.

  9. Three-dimensional near-field MIMO array imaging using range migration techniques.

    Science.gov (United States)

    Zhuge, Xiaodong; Yarovoy, Alexander G

    2012-06-01

    This paper presents a 3-D near-field imaging algorithm that is formulated for 2-D wideband multiple-input-multiple-output (MIMO) imaging array topology. The proposed MIMO range migration technique performs the image reconstruction procedure in the frequency-wavenumber domain. The algorithm is able to completely compensate the curvature of the wavefront in the near-field through a specifically defined interpolation process and provides extremely high computational efficiency by the application of the fast Fourier transform. The implementation aspects of the algorithm and the sampling criteria of a MIMO aperture are discussed. The image reconstruction performance and computational efficiency of the algorithm are demonstrated both with numerical simulations and measurements using 2-D MIMO arrays. Real-time 3-D near-field imaging can be achieved with a real-aperture array by applying the proposed MIMO range migration techniques.

  10. Adapting range migration techniques for imaging with metasurface antennas: analysis and limitations

    Science.gov (United States)

    Pulido Mancera, Laura; Fromenteze, Thomas; Sleasman, Timothy; Boyarsky, Michael; Imani, Mohammadreza F.; Reynolds, Matthew S.; Smith, David R.

    2017-04-01

    Dynamic metasurface antennas are planar structures that exhibit remarkable capabilities in controlling electromagnetic wave-fronts, advantages which are particularly attractive for microwave imaging. These antennas exhibit strong frequency dispersion and produce diverse radiation patterns. Such behavior presents unique challenges for integration with conventional imaging algorithms. We analyze an adapted version of the range migration algorithm (RMA) for use with dynamic metasurfaces in image reconstruction. Focusing on the the proposed pre-processing step, that ultimately allows a fast processing of the backscattered signal in the spatial frequency domain from which the fast Fourier transform can efficiently reconstruct the scene. Numerical studies illustrate imaging performance using both conventional methods and the adapted RMA, demonstrating that the RMA can reconstruct images with comparable quality in a fraction of the time. In this paper, we demonstrate the capabilities of the algorithm as a fast reconstruction tool, and we analyze the limitations of the presented technique in terms of image quality.

  11. A comprehensive study on HDR brachytherapy treatments of cervical cancers: using the first Co-60 BEBIG Multisource Unit in Bangladesh

    Directory of Open Access Journals (Sweden)

    Naheed Rukhsana

    2011-07-01

    Full Text Available Purpose: The report presents an extraordinary synthesis of customer acceptance procedures (CAP, quality assurance tests (QA in the treatment of cervical cancer patients, using the first Co-60 Multisource Unit® in Bangladesh. The QA and commissioning required measurements and emergency tests verifying the functional limits of parameters acceptable for the new HDR afterloader. Acceptable limits were: 1 the deviation between specified and measured source strength: ± 3%; 2 the positional accuracy and uniformity: ± 1 mm; 3 the temporal accuracy (i.e. timer error and linearity and end error: ± 1% or 30 sec.; 4 treatment planning system (digitizer and localization software: ± 3% or 1 mm; 5 the distance from line to first dwell position and all the others: 5 mm and 10 mm (± 1 mm. Material and methods: Till February 2011, 47 patients were treated with HDR with more than 140 insertions applied. Amongst them, 12 patients were in stage IIB and IIIB, 22 were postoperative (IA and IB while the remaining 13 patients were with unknown stage. All the cases with stage IIB and IIIB received concurrent chemo-radiation and brachytherapy. Postoperative patients received EBRT (50 Gy and HDR according to the institutional protocol. CT scans were completed before HDR-plus planning with a good reproducibility (± 2% and were documented in repeating the plan for the same set up of a patient. Absorbed dose (Gy to a point P, at a distance of “r” in centimeters from a source of the Reference Air Kerma Rate (RAKR has been utilized for the QA of the source, where source strength measurement was accomplished. Results: All methods and analysis applicable to the QA and commissioning of Co-60 have been investigated and systematically analyzed, measured and documented before the treatment of a patient. Studies and safety requirements of this HDR remote afterloader were carried out. Acceptance and the QA were imperative to justify functionality and dependability in

  12. A comprehensive study on HDR brachytherapy treatments of cervical cancers: using the first Co-60 BEBIG Multisource Unit in Bangladesh.

    Science.gov (United States)

    Malik, Sadiq R; Banu, Parvin A; Rukhsana, Naheed

    2011-06-01

    The report presents an extraordinary synthesis of customer acceptance procedures (CAP), quality assurance tests (QA) in the treatment of cervical cancer patients, using the first Co-60 Multisource Unit® in Bangladesh. The QA and commissioning required measurements and emergency tests verifying the functional limits of parameters acceptable for the new HDR afterloader. Acceptable limits were: 1) the deviation between specified and measured source strength: ± 3%; 2) the positional accuracy and uniformity: ± 1 mm; 3) the temporal accuracy (i.e. timer error and linearity and end error): ± 1% or 30 sec.; 4) treatment planning system (digitizer and localization software): ± 3% or 1 mm; 5) the distance from line to first dwell position and all the others: 5 mm and 10 mm (± 1 mm). Till February 2011, 47 patients were treated with HDR with more than 140 insertions applied. Amongst them, 12 patients were in stage IIB and IIIB, 22 were postoperative (IA and IB) while the remaining 13 patients were with unknown stage. All the cases with stage IIB and IIIB received concurrent chemo-radiation and brachytherapy. Postoperative patients received EBRT (50 Gy and HDR) according to the institutional protocol. CT scans were completed before HDR-plus planning with a good reproducibility (± 2%) and were documented in repeating the plan for the same set up of a patient. Absorbed dose (Gy) to a point P, at a distance of "r" in centimeters from a source of the Reference Air Kerma Rate (RAKR) has been utilized for the QA of the source, where source strength measurement was accomplished. All methods and analysis applicable to the QA and commissioning of Co-60 have been investigated and systematically analyzed, measured and documented before the treatment of a patient. Studies and safety requirements of this HDR remote afterloader were carried out. Acceptance and the QA were imperative to justify functionality and dependability in delivering the treatment. Implications of these studies

  13. Supplementary Golay pair for range side lobe suppression in dual-frequency tissue harmonic imaging.

    Science.gov (United States)

    Shen, Che-Chou; Wu, Chi; Peng, Jun-Kai

    2015-02-01

    In dual-frequency (DF) harmonic imaging, the second harmonic signal at second harmonic (2f0) frequency and the inter-modulation harmonic signal at fundamental (f0) frequency are simultaneously imaged for spectral compounding. When the phase-encoded Golay pair is utilized to improve the harmonic signal-to-noise ratio (SNR), however, the DF imaging suffers from range side lobe artifacts due to spectral cross-talk with other harmonic components at DC and third harmonic (3f0) frequency. In this study, a supplementary Golay pair is developed to suppress the range side lobes in combination with the original Golay pair. Since the phase code of the DC interference cannot be manipulated, the supplementary Golay is designed to reverse the polarity of the 3f0 interference and the f0 signal while keeping the 2f0 signal unchanged. For 2f0 imaging, the echo summation of the supplementary and the original Golay can cancel the 3f0 interference. On the contrary, the echo difference between the two Golay pairs can eliminate the DC interference for f0 imaging. Hydrophone measurements indicate that the range side lobe level (RSLL) increases with the signal bandwidth of DF harmonic imaging. By using the combination of the two Golay pairs, the achievable suppression of RSLL can be 3 and 14 dB, respectively for the f0 and 2f0 harmonic signal. B-mode phantom imaging also verifies the presence of range side lobe artifacts when only the original Golay pair is utilized. In combination with the supplementary Golay pair, the artifacts are effectively suppressed. The corresponding range side lobe magnitude reduces by about 8 dB in 2f0 imaging but remains unchanged in f0 imaging. Meanwhile, the harmonic SNR improves by 8-10 dB and the contrast-to-noise ratio of harmonic image increases from about 1 to 1.2 by spectral compounding. For DF tissue harmonic imaging, the spectral cross-talk in Golay excitation results in severe range side lobe artifacts. To restore the image quality, two particular

  14. Determination of visual range during fog and mist using digital camera images

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, John R; Moogan, Jamie C, E-mail: j.taylor@adfa.edu.a [School of Physical, Environmental and Mathematical Sciences, UNSW-ADFA, Canberra ACT, 2600 (Australia)

    2010-08-15

    During the winter of 2008, daily time series of images of five 'unit-cell chequerboard' targets were acquired using a digital camera. The camera and targets were located in the Majura Valley approximately 3 km from Canberra airport. We show how the contrast between the black and white sections of the targets is related to the meteorological range (or standard visual range), and compare estimates of this quantity derived from images acquired during fog and mist conditions with those from the Vaisala FD-12 visibility meter operated by the Bureau of Meteorology at Canberra Airport. The two sets of ranges are consistent but show the variability of visibility in the patchy fog conditions that often prevail in the Majura Valley. Significant spatial variations of the light extinction coefficient were found to occur over the longest 570 m optical path sampled by the imaging system. Visual ranges could be estimated out to ten times the distance to the furthest target, or approximately 6 km, in these experiments. Image saturation of the white sections of the targets was the major limitation on the quantitative interpretation of the images. In the future, the camera images will be processed in real time so that the camera exposure can be adjusted to avoid saturation.

  15. A new compact, cost-efficient concept for underwater range-gated imaging: the UTOFIA project

    Science.gov (United States)

    Mariani, Patrizio; Quincoces, Iñaki; Galparsoro, Ibon; Bald, Juan; Gabiña, Gorka; Visser, Andy; Jónasdóttir, Sigrun; Haugholt, Karl Henrik; Thorstensen, Jostein; Risholm, Petter; Thielemann, Jens

    2017-04-01

    Underwater Time Of Flight Image Acquisition system (UTOFIA) is a recently launched H2020 project (H2020 - 633098) to develop a compact and cost-effective underwater imaging system especially suited for observations in turbid environments. The UTOFIA project targets technology that can overcome the limitations created by scattering, by introducing cost-efficient range-gated imaging for underwater applications. This technology relies on a image acquisition principle that can extends the imaging range of the cameras 2-3 times respect to other cameras. Moreover, the system will simultaneously capture 3D information of the observed objects. Today range-gated imaging is not widely used, as it relies on specialised optical components making systems large and costly. Recent technology developments have made it possible a significant (2-3 times) reduction in size, complexity and cost of underwater imaging systems, whilst addressing the scattering issues at the same time. By acquiring simultaneous 3D data, the system allows to accurately measure the absolute size of marine life and their spatial relationship to their habitat, enhancing the precision of fish stock monitoring and ecology assessment, hence supporting proper management of marine resources. Additionally, the larger observed volume and the improved image quality make the system suitable for cost-effective underwater surveillance operations in e.g. fish farms, underwater infrastructures. The system can be integrated into existing ocean observatories for real time acquisition and can greatly advance present efforts in developing species recognition algorithms, given the additional features provided, the improved image quality and the independent illumination source based on laser. First applications of the most recent prototype of the imaging system will be provided including inspection of underwater infrastructures and observations of marine life under different environmental conditions.

  16. A comparative analysis of dynamic range compression techniques in IR images for maritime applications

    Science.gov (United States)

    Rossi, Alessandro; Acito, Nicola; Diani, Marco; Luison, Cristian; Olivieri, Monica; Barani, Gianni

    2013-05-01

    Modern thermal cameras acquire IR images with a high dynamic range because they have to sense with high thermal resolution the great temperature changes of monitored scenarios in specific surveillance applications. Initially developed for visible light images and recently extended for display of IR images, high dynamic range compression (HDRC) techniques aim at furnishing plain images to human operators for a first intuitive comprehension of the sensed scenario without altering the features of IR images. In this context, the maritime scenario represents a challenging case to test and develop HDRC strategies since images collected for surveillance at sea are typically characterized by high thermal gradients among the background scene and classes of objects at different temperatures. In the development of a new IRST system, Selex ES assembled a demonstrator equipped with modern thermal cameras and planned a measurement campaign on a maritime scenario so as to collect IR sequences in different operating conditions. This has led to build up a case record of situations suitable to test HDRC techniques. In this work, a survey of HDRC approaches is introduced pointing out advantages and drawbacks with focus on strategies specifically designed to display IR images. A detailed analysis of the performance is discussed in order to address the task of visualization with reference to typical issues of IR maritime images, such as robustness to the horizon effect and displaying of very warm objects and flat areas.

  17. The use of a measure with a strong correlation with the visual system to analyze the influence of the acquisition conditions over image quality in panoramic dental images; Implementacion de una medida objetiva de fuerte correlacion con el sistema visual humano para analizar la influencia de las condiciones de adquisicion sobre la calidad de las imagenes panoramicas dentales

    Energy Technology Data Exchange (ETDEWEB)

    Perez Diaz, M.; Miranda Castaneda, I.; Borges Garcia, T.

    2012-07-01

    The High Dynamic Range Visible Difference Predictor (HDR-VDP) was created to overcome the poor correlation between objective and subjective digital image quality criteria. This metric has been successfully tested to analyze the effect of medical images compression over image quality. A study using 13 dental panoramic images of an anthropomorphic phantom was carried out. Images were acquired with a digital Kodak equipment. Tube current and beam energy were changed among studies in order to analyze how the image quality was affected by the acquisition parameters variation. The criterion about image quality of two expert observers was taken into account. Furthermore, HDR-VDP was fitted to the problem under analysis. Correlation between the metric and the subjective criterion was also analyzed. HDR-VDP had a correlation of r 0.683 (p = 0. 013) with respect to the subjective criterion. The metric calculated over 9 x 9 pixel windows in regions of interest was able to detect differences in image quality for a typical range of kVp and mA in this type of study. (Author) 17 refs.

  18. The use of nomograms in LDR-HDR prostate brachytherapy

    Directory of Open Access Journals (Sweden)

    Ma Carmen Pujades

    2011-09-01

    Full Text Available Purpose: The common use of nomograms in Low Dose Rate (LDR permanent prostate brachytherapy (BT allowsto estimate the number of seeds required for an implant. Independent dosimetry verification is recommended for eachclinical dosimetry in BT. Also, nomograms can be useful for dose calculation quality assurance and they could be adaptedto High Dose Rate (HDR. This work sets nomograms for LDR and HDR prostate-BT implants, which are applied tothree different institutions that use different implant techniques. Material and methods: Patients treated throughout 2010 till April 2011 were considered for this study. This examplewas chosen to be the representative of the latest implant techniques and to ensure consistency in the planning. A sufficientnumber of cases for both BT modalities, prescription dose and different work methodology (depending on theinstitution were taken into account. The specific nomograms were built using the correlation between the prostatevo lume and some characteristic parameters of each BT modality, such as the source Air Kerma Strength, numberof implanted seeds in LDR or total radiation time in HDR. Results: For each institution and BT modality, nomograms normalized to the prescribed dose were obtained andfitted to a linear function. The parameters of the adjustment show a good agreement between data and the fitting.It should be noted that for each institution these linear function parameters are different, indicating that each centreshould construct its own nomograms. Conclusions: Nomograms for LDR and HDR prostate brachytherapy are simple quality assurance tools, specific foreach institution. Nevertheless, their use should be complementary to the necessary independent verification.

  19. Analysis on expressible depth range of integral imaging based on degree of voxel overlap.

    Science.gov (United States)

    Kim, Young Min; Choi, Ki-Hong; Min, Sung-Wook

    2017-02-01

    This paper proposes a practical method to analyze the expressible depth range of an integral imaging system based on image blur at defocused depths, which is one of the most noticeable image degradations, caused by overlaps among voxels in both the real and focused mode. In order to obtain the preferably precise area of overlaps among voxels at each depth, display pixels are regarded as surface light sources in the process of voxel size calculation. As a criterion for determining the range, we determine the tolerable limit of the overlaps among voxels to be at least resolved from each other. Based on this principle, several mathematical expressions about the expressible depth range can be derived in both the real mode and focused mode, and their feasibilities are demonstrated by several experiments. The analyses are processed based on both wave optics and ray optics.

  20. Improvement of range spatial resolution of medical ultrasound imaging by element-domain signal processing

    Science.gov (United States)

    Hasegawa, Hideyuki

    2017-07-01

    The range spatial resolution is an important factor determining the image quality in ultrasonic imaging. The range spatial resolution in ultrasonic imaging depends on the ultrasonic pulse length, which is determined by the mechanical response of the piezoelectric element in an ultrasonic probe. To improve the range spatial resolution without replacing the transducer element, in the present study, methods based on maximum likelihood (ML) estimation and multiple signal classification (MUSIC) were proposed. The proposed methods were applied to echo signals received by individual transducer elements in an ultrasonic probe. The basic experimental results showed that the axial half maximum of the echo from a string phantom was improved from 0.21 mm (conventional method) to 0.086 mm (ML) and 0.094 mm (MUSIC).

  1. Computational ghost imaging of hot objects in long-wave infrared range

    Science.gov (United States)

    Liu, Hong-Chao; Zhang, Shuang

    2017-07-01

    Ghost imaging (GI) is an intriguing imaging modality to obtain the object information from the correlation calculations of spatial intensity fluctuations. In this letter, we report the computational GI of hot objects in the long-wave infrared range both in experiment and simulation. Without employing an independent light source, we reconstruct thermal images of objects only based on the intensity correlations of their thermal radiation at room temperature. By comparing different GI reconstruction algorithms, we demonstrate that GI with compressive sensing can efficiently obtain the thermal object information only with a single-pixel infrared camera, which might be applied to night-vision, environmental sensing, military detection, etc.

  2. [Influence of human body target's spectral characteristics on visual range of low light level image intensifiers].

    Science.gov (United States)

    Zhang, Jun-Ju; Yang, Wen-Bin; Xu, Hui; Liu, Lei; Tao, Yuan-Yaun

    2013-11-01

    To study the effect of different human target's spectral reflective characteristic on low light level (LLL) image intensifier's distance, based on the spectral characteristics of the night-sky radiation and the spectral reflective coefficients of common clothes, we established a equation of human body target's spectral reflective distribution, and analyzed the spectral reflective characteristics of different human targets wearing the clothes of different color and different material, and from the actual detection equation of LLL image intensifier distance, discussed the detection capability of LLL image intensifier for different human target. The study shows that the effect of different human target's spectral reflective characteristic on LLL image intensifier distance is mainly reflected in the average reflectivity rho(-) and the initial contrast of the target and the background C0. Reflective coefficient and spectral reflection intensity of cotton clothes are higher than polyester clothes, and detection capability of LLL image intensifier is stronger for the human target wearing cotton clothes. Experimental results show that the LLL image intensifiers have longer visual ranges for targets who wear cotton clothes than targets who wear same color but polyester clothes, and have longer visual ranges for targets who wear light-colored clothes than targets who wear dark-colored clothes. And in the full moon illumination conditions, LLL image intensifiers are more sensitive to the clothes' material.

  3. ATCOM: accelerated image processing for terrestrial long-range imaging through atmospheric effects

    Science.gov (United States)

    Curt, Petersen F.; Paolini, Aaron

    2013-05-01

    Long-range video surveillance performance is often severely diminished due to atmospheric turbulence. The larger apertures typically used for video-rate operation at long-range are particularly susceptible to scintillation and blurring effects that limit the overall diffraction efficiency and resolution. In this paper, we present research progress made toward a digital signal processing technique which aims to mitigate the effects of turbulence in real-time. Our previous work in this area focused on an embedded implementation for portable applications. Our more recent research has focused on functional enhancements to the same algorithm using general-purpose hardware. We present some techniques that were successfully employed to accelerate processing of high-definition color video streams and study performance under nonideal conditions involving moving objects and panning cameras. Finally, we compare the real-time performance of two implementations using a CPU and a GPU.

  4. Polarized Imaging Lidar Using Underwater Range Gating in a Multifunctional Remote Sensing System.

    Science.gov (United States)

    Fournier, G.; Trees, C.

    2016-02-01

    This work describes the design of a compact imaging underwater polarized LIDAR system using a new modular laser beam shaping technology, which ensures eye safe operation at significant optical power levels that were previously unattainable in such an eye safe mode. The system is based on an existing battery powered high efficiency compact range-gated system which can be operated from a variety of underwater vehicles including AUV's. A detailed analysis is presented of the procedure required to successfully extract information on the depth distribution of the inherent optical properties along with the shape of the phase function in the near forward direction. The effect of polarization in helping to constrain and improve the retrieval of these fundamental optical properties of the water column is also discussed. The LIDAR mode is shown to be only one of the many functionalities useful to oceanographic research, which can be implemented using the beam shaping technology described above. Beyond the improvement in range and image quality of gated imaging over conventional imaging in turbid waters, the application of gated-structured imaging can be shown to significantly improve range and precision of 3D bottom mapping near the turbid seabed environment. We will show that the spatial precision that is available is sufficient for seabed habitat mapping and litter identification required for an environmental impact evaluation.

  5. Investigation of the impact of water absorption on retinal OCT imaging in the 1060 nm range

    DEFF Research Database (Denmark)

    Marschall, Sebastian; Pedersen, Christian; Andersen, Peter E.

    2012-01-01

    Recently, the wavelength range around 1060 nm has become attractive for retinal imaging with optical coherence tomography (OCT), promising deep penetration into the retina and the choroid. The adjacent water absorption bands limit the useful bandwidth of broadband light sources, but until now...... sources for OCT....

  6. Short-Range Ultra-Wideband Imaging with Multiple-Input Multiple-Output Arrays

    NARCIS (Netherlands)

    Zhuge, X.

    2010-01-01

    Compact, cost-efficient and high-resolution imaging sensors are especially desirable in the field of short-range observation and surveillance. Such sensors are of great value in fields of security, rescue and medical applications. Systems can be formed for various practical purposes, such as

  7. Moving target detection in flash mode against stroboscopic mode by active range-gated laser imaging

    Science.gov (United States)

    Zhang, Xuanyu; Wang, Xinwei; Sun, Liang; Fan, Songtao; Lei, Pingshun; Zhou, Yan; Liu, Yuliang

    2018-01-01

    Moving target detection is important for the application of target tracking and remote surveillance in active range-gated laser imaging. This technique has two operation modes based on the difference of the number of pulses per frame: stroboscopic mode with the accumulation of multiple laser pulses per frame and flash mode with a single shot of laser pulse per frame. In this paper, we have established a range-gated laser imaging system. In the system, two types of lasers with different frequency were chosen for the two modes. Electric fan and horizontal sliding track were selected as the moving targets to compare the moving blurring between two modes. Consequently, the system working in flash mode shows more excellent performance in motion blurring against stroboscopic mode. Furthermore, based on experiments and theoretical analysis, we presented the higher signal-to-noise ratio of image acquired by stroboscopic mode than flash mode in indoor and underwater environment.

  8. A comparison of interest point and region detectors on structured, range and texture images

    DEFF Research Database (Denmark)

    Kazmi, Wajahat; Andersen, Hans Jørgen

    2015-01-01

    )) and corner based detectors (such as Hessian and Harris with both Affine/Laplace variants, SURF with determinant of Hessian based corners and SIFT with difference of Gaussians) acquired more than 90% mean average precision, whereas on range images, homogeneous region detector did not work well. TLR offered...... and textured images. It is also shown that in a bi-channel approach, combining surface and edge regions (MSER and TLR) boosts the overall performance. Among the descriptors, SIFT and SURF generally offer higher performance but low dimensional descriptors such as Steerable Filters follow closely.......This article presents an evaluation of the image retrieval and classification potential of local features. Several affine invariant region and scale invariant interest point detectors in combination with well known descriptors were evaluated. Tests on building, range and texture databases were...

  9. Hardware-based smart camera for recovering high dynamic range video from multiple exposures

    Science.gov (United States)

    Lapray, Pierre-Jean; Heyrman, Barthélémy; Ginhac, Dominique

    2014-10-01

    In many applications such as video surveillance or defect detection, the perception of information related to a scene is limited in areas with strong contrasts. The high dynamic range (HDR) capture technique can deal with these limitations. The proposed method has the advantage of automatically selecting multiple exposure times to make outputs more visible than fixed exposure ones. A real-time hardware implementation of the HDR technique that shows more details both in dark and bright areas of a scene is an important line of research. For this purpose, we built a dedicated smart camera that performs both capturing and HDR video processing from three exposures. What is new in our work is shown through the following points: HDR video capture through multiple exposure control, HDR memory management, HDR frame generation, and representation under a hardware context. Our camera achieves a real-time HDR video output at 60 fps at 1.3 megapixels and demonstrates the efficiency of our technique through an experimental result. Applications of this HDR smart camera include the movie industry, the mass-consumer market, military, automotive industry, and surveillance.

  10. The New Approach of Using Image and Range Based Methods for Quality Control of Dimension Stone

    Science.gov (United States)

    Levytskyi, Volodymyr

    2017-06-01

    The basis for the quality control of commodity dimension stone blocks for mining industry is the study of fracturing. The identification of fracturing in rock masses is one of the most important aspects in rock mass modelling. Traditional methods for determination properties of fracturing are difficult and hazardous. This paper describes a new approach of fracturing identification, based on image and range data, which realized by image processing and special software. In this article describes a method using new computer algorithms that allow for automated identification and calculation of fracturing parameters. Different digital filters for image processing and mathematical dependences are analyzed. The digital imaging technique has the potential for being used in real time applications. The purpose of this paper is the accurate and fast mapping of fracturing in some walls of the Bukinsky gabbro deposit.

  11. Image seeker simulation for short-range surface-to-surface missile

    Science.gov (United States)

    Jin, Sang-Hun; Kang, Ho-Gyun

    2007-04-01

    This paper presents an image seeker simulation including image processing, servo control, target model, and missile trajectory. We propose a software architecture for a seeker embedded computer. It makes core processing algorithms including image processing reusable at the source level through multiple platforms. The embedded software simulator implemented in C/C++, the servo control simulator implemented in Matlab, and the integrated simulator combined the both simulators based on Windows Component Object Module (COM) technology is presented. The integrated simulation enables developers to practice an interactive study between image processing and servo control about missions including lock-on and target tracking. The implemented simulator can be operated in low cost computer systems. This can be used to algorithm development and analysis at the design, implementation, and evaluation. Simulation examples for a short range ground-to-ground missile seeker are presented.

  12. Polymer-free optode nanosensors for dynamic, reversible, and ratiometric sodium imaging in the physiological range.

    Science.gov (United States)

    Ruckh, Timothy T; Mehta, Ankeeta A; Dubach, J Matthew; Clark, Heather A

    2013-11-28

    This work introduces a polymer-free optode nanosensor for ratiometric sodium imaging. Transmembrane ion dynamics are often captured by electrophysiology and calcium imaging, but sodium dyes suffer from short excitation wavelengths and poor selectivity. Optodes, optical sensors composed of a polymer matrix with embedded sensing chemistry, have been translated into nanosensors that selectively image ion concentrations. Polymer-free nanosensors were fabricated by emulsification and were stable by diameter and sensitivity for at least one week. Ratiometric fluorescent measurements demonstrated that the nanosensors are selective for sodium over potassium by ~1.4 orders of magnitude, have a dynamic range centered at 20 mM, and are fully reversible. The ratiometric signal changes by 70% between 10 and 100 mM sodium, showing that they are sensitive to changes in sodium concentration. These nanosensors will provide a new tool for sensitive and quantitative ion imaging.

  13. Quantitative analysis of velopharyngeal movement using a stereoendoscope: accuracy and reliability of range images.

    Science.gov (United States)

    Nakano, Asuka; Mishima, Katsuaki; Shiraishi, Ruriko; Ueyama, Yoshiya

    2015-01-01

    We developed a novel method of producing accurate range images of the velopharynx using a three-dimensional (3D) endoscope to obtain detailed measurements of velopharyngeal movements. The purpose of the present study was to determine the relationship between the distance from the endoscope to an object, elucidate the measurement accuracy along the temporal axes, and determine the degree of blurring when using a jig to fix the endoscope. An endoscopic measuring system was developed in which a pattern projection system was incorporated into a commercially available 3D endoscope. After correcting the distortion of the camera images, range images were produced using pattern projection to achieve stereo matching. Graph paper was used to measure the appropriate distance from the camera to an object, the mesial buccal cusp of the right maxillary first molar was measured to clarify the range image stability, and an electric actuator was used to evaluate the measurement accuracy along the temporal axes. The measurement error was substantial when the distance from the camera to the subject was >6.5 cm. The standard error of the 3D coordinate value produced from 30 frames was within 0.1 mm (range, 0.01-0.08 mm). The measurement error of the temporal axes was 9.16% in the horizontal direction and 9.27% in the vertical direction. The optimal distance from the camera to an object is <6.5 cm. The present endoscopic measuring system can provide stable range images of the velopharynx when using an appropriate fixation method and enables quantitative analysis of velopharyngeal movements.

  14. Positron range in PET imaging: an alternative approach for assessing and correcting the blurring

    DEFF Research Database (Denmark)

    Jødal, Lars; Le Loirec, Cindy; Champion, Christophe

    2012-01-01

    Background: Positron range impairs resolution in PET imaging, especially for high-energy emitters and for small-animal PET. De-blurring in image reconstruction is possible if the blurring distribution is known. Further, the percentage of annihilation events within a given distance from the point...... of positron emission is relevant for assessing statistical noise. Aims: The paper aims to determine positron range distribution relevant for blurring for seven medically relevant PET isotopes, 18F, 11C, 13N, 15O, 68Ga, 62Cu, and 82Rb, and derive empirical formulas for the distributions. The paper focuses...... on allowed-decay isotopes. Methods: It is argued that blurring at the detection level should not be described by positron range r, but instead the 2D-projected distance δ (equal to the closest distance between decay and line-of-response). To determine these 2D distributions, results from a dedicated positron...

  15. Stochastic calculus analysis of optical time-of-flight range imaging and estimation of radial motion.

    Science.gov (United States)

    Streeter, Lee

    2017-07-01

    Time-of-flight range imaging is analyzed using stochastic calculus. Through a series of interpretations and simplifications, the stochastic model leads to two methods for estimating linear radial velocity: maximum likelihood estimation on the transition probability distribution between measurements, and a new method based on analyzing the measured correlation waveform and its first derivative. The methods are tested in a simulated motion experiment from (-40)-(+40)  m/s, with data from a camera imaging an object on a translation stage. In tests maximum likelihood is slow and unreliable, but when it works it estimates the linear velocity with standard deviation of 1 m/s or better. In comparison the new method is fast and reliable but works in a reduced velocity range of (-20)-(+20)  m/s with standard deviation ranging from 3.5 m/s to 10 m/s.

  16. Image simulation and a model of noise power spectra across a range of mammographic beam qualities.

    Science.gov (United States)

    Mackenzie, Alistair; Dance, David R; Diaz, Oliver; Young, Kenneth C

    2014-12-01

    The aim of this work is to create a model to predict the noise power spectra (NPS) for a range of mammographic radiographic factors. The noise model was necessary to degrade images acquired on one system to match the image quality of different systems for a range of beam qualities. Five detectors and x-ray systems [Hologic Selenia (ASEh), Carestream computed radiography CR900 (CRc), GE Essential (CSI), Carestream NIP (NIPc), and Siemens Inspiration (ASEs)] were characterized for this study. The signal transfer property was measured as the pixel value against absorbed energy per unit area (E) at a reference beam quality of 28 kV, Mo/Mo or 29 kV, W/Rh with 45 mm polymethyl methacrylate (PMMA) at the tube head. The contributions of the three noise sources (electronic, quantum, and structure) to the NPS were calculated by fitting a quadratic at each spatial frequency of the NPS against E. A quantum noise correction factor which was dependent on beam quality was quantified using a set of images acquired over a range of radiographic factors with different thicknesses of PMMA. The noise model was tested for images acquired at 26 kV, Mo/Mo with 20 mm PMMA and 34 kV, Mo/Rh with 70 mm PMMA for three detectors (ASEh, CRc, and CSI) over a range of exposures. The NPS were modeled with and without the noise correction factor and compared with the measured NPS. A previous method for adapting an image to appear as if acquired on a different system was modified to allow the reference beam quality to be different from the beam quality of the image. The method was validated by adapting the ASEh flat field images with two thicknesses of PMMA (20 and 70 mm) to appear with the imaging characteristics of the CSI and CRc systems. The quantum noise correction factor rises with higher beam qualities, except for CR systems at high spatial frequencies, where a flat response was found against mean photon energy. This is due to the dominance of secondary quantum noise in CR. The use of the

  17. Image simulation and a model of noise power spectra across a range of mammographic beam qualities

    Energy Technology Data Exchange (ETDEWEB)

    Mackenzie, Alistair, E-mail: alistairmackenzie@nhs.net; Dance, David R.; Young, Kenneth C. [National Coordinating Centre for the Physics of Mammography, Royal Surrey County Hospital, Guildford GU2 7XX, United Kingdom and Department of Physics, University of Surrey, Guildford GU2 7XH (United Kingdom); Diaz, Oliver [Centre for Vision, Speech and Signal Processing, Faculty of Engineering and Physical Sciences, University of Surrey, Guildford GU2 7XH, United Kingdom and Computer Vision and Robotics Research Institute, University of Girona, Girona 17071 (Spain)

    2014-12-15

    Purpose: The aim of this work is to create a model to predict the noise power spectra (NPS) for a range of mammographic radiographic factors. The noise model was necessary to degrade images acquired on one system to match the image quality of different systems for a range of beam qualities. Methods: Five detectors and x-ray systems [Hologic Selenia (ASEh), Carestream computed radiography CR900 (CRc), GE Essential (CSI), Carestream NIP (NIPc), and Siemens Inspiration (ASEs)] were characterized for this study. The signal transfer property was measured as the pixel value against absorbed energy per unit area (E) at a reference beam quality of 28 kV, Mo/Mo or 29 kV, W/Rh with 45 mm polymethyl methacrylate (PMMA) at the tube head. The contributions of the three noise sources (electronic, quantum, and structure) to the NPS were calculated by fitting a quadratic at each spatial frequency of the NPS against E. A quantum noise correction factor which was dependent on beam quality was quantified using a set of images acquired over a range of radiographic factors with different thicknesses of PMMA. The noise model was tested for images acquired at 26 kV, Mo/Mo with 20 mm PMMA and 34 kV, Mo/Rh with 70 mm PMMA for three detectors (ASEh, CRc, and CSI) over a range of exposures. The NPS were modeled with and without the noise correction factor and compared with the measured NPS. A previous method for adapting an image to appear as if acquired on a different system was modified to allow the reference beam quality to be different from the beam quality of the image. The method was validated by adapting the ASEh flat field images with two thicknesses of PMMA (20 and 70 mm) to appear with the imaging characteristics of the CSI and CRc systems. Results: The quantum noise correction factor rises with higher beam qualities, except for CR systems at high spatial frequencies, where a flat response was found against mean photon energy. This is due to the dominance of secondary quantum noise

  18. High-dynamic range compressive spectral imaging by grayscale coded aperture adaptive filtering

    Directory of Open Access Journals (Sweden)

    Nelson Eduardo Diaz

    2015-12-01

    Full Text Available The coded aperture snapshot spectral imaging system (CASSI is an imaging architecture which senses the three dimensional informa-tion of a scene with two dimensional (2D focal plane array (FPA coded projection measurements. A reconstruction algorithm takes advantage of the compressive measurements sparsity to recover the underlying 3D data cube. Traditionally, CASSI uses block-un-block coded apertures (BCA to spatially modulate the light. In CASSI the quality of the reconstructed images depends on the design of these coded apertures and the FPA dynamic range. This work presents a new CASSI architecture based on grayscaled coded apertu-res (GCA which reduce the FPA saturation and increase the dynamic range of the reconstructed images. The set of GCA is calculated in a real-time adaptive manner exploiting the information from the FPA compressive measurements. Extensive simulations show the attained improvement in the quality of the reconstructed images when GCA are employed.  In addition, a comparison between traditional coded apertures and GCA is realized with respect to noise tolerance.

  19. WE-A-17A-06: Evaluation of An Automatic Interstitial Catheter Digitization Algorithm That Reduces Treatment Planning Time and Provide Means for Adaptive Re-Planning in HDR Brachytherapy of Gynecologic Cancers

    Energy Technology Data Exchange (ETDEWEB)

    Dise, J [Philadelphia, PA (United States); Liang, X; Lin, L [University of Pennsylvania, Philadelphia, Pennsylvania (United States); Teo, B [University of Pennsylvania, Wayne, PA (United States)

    2014-06-15

    Purpose: To evaluate an automatic interstitial catheter digitization algorithm that reduces treatment planning time and provide means for adaptive re-planning in HDR Brachytherapy of Gynecologic Cancers. Methods: The semi-automatic catheter digitization tool utilizes a region growing algorithm in conjunction with a spline model of the catheters. The CT images were first pre-processed to enhance the contrast between the catheters and soft tissue. Several seed locations were selected in each catheter for the region growing algorithm. The spline model of the catheters assisted in the region growing by preventing inter-catheter cross-over caused by air or metal artifacts. Source dwell positions from day one CT scans were applied to subsequent CTs and forward calculated using the automatically digitized catheter positions. This method was applied to 10 patients who had received HDR interstitial brachytherapy on an IRB approved image-guided radiation therapy protocol. The prescribed dose was 18.75 or 20 Gy delivered in 5 fractions, twice daily, over 3 consecutive days. Dosimetric comparisons were made between automatic and manual digitization on day two CTs. Results: The region growing algorithm, assisted by the spline model of the catheters, was able to digitize all catheters. The difference between automatic and manually digitized positions was 0.8±0.3 mm. The digitization time ranged from 34 minutes to 43 minutes with a mean digitization time of 37 minutes. The bulk of the time was spent on manual selection of initial seed positions and spline parameter adjustments. There was no significance difference in dosimetric parameters between the automatic and manually digitized plans. D90% to the CTV was 91.5±4.4% for the manual digitization versus 91.4±4.4% for the automatic digitization (p=0.56). Conclusion: A region growing algorithm was developed to semi-automatically digitize interstitial catheters in HDR brachytherapy using the Syed-Neblett template. This automatic

  20. Influence of the particle size on polarization-based range-gated imaging in turbid media

    Directory of Open Access Journals (Sweden)

    Heng Tian

    2017-09-01

    Full Text Available The influence of size of the scatterer on the image contrast for polarization-based range-gated imaging in turbid media is investigated here by Monte Carlo method. Circularly polarized light would be more efficient to eliminate the noise photons for both the isotropic medium as well as the anisotropic medium, as compared with linearly polarized light. The improvement in contrast is pronounced for isotropic medium using either linear or circular polarization. The plausible explanations for these observations are also presented.

  1. Prototype system for proton beam range measurement based on gamma electron vertex imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Han Rim [Neutron Utilization Technology Division, Korea Atomic Energy Research Institute, 111, Daedeok-daero 989beon-gil, Yuseong-gu, Daejeon 34057 (Korea, Republic of); Kim, Sung Hun; Park, Jong Hoon [Department of Nuclear Engineering, Hanyang University, Seongdong-gu, Seoul 04763 (Korea, Republic of); Jung, Won Gyun [Heavy-ion Clinical Research Division, Korean Institute of Radiological & Medical Sciences, Seoul 01812 (Korea, Republic of); Lim, Hansang [Department of Electronics Convergence Engineering, Kwangwoon University, Seoul 01897 (Korea, Republic of); Kim, Chan Hyeong, E-mail: chkim@hanyang.ac.kr [Department of Nuclear Engineering, Hanyang University, Seongdong-gu, Seoul 04763 (Korea, Republic of)

    2017-06-11

    In proton therapy, for both therapeutic effectiveness and patient safety, it is very important to accurately measure the proton dose distribution, especially the range of the proton beam. For this purpose, recently we proposed a new imaging method named gamma electron vertex imaging (GEVI), in which the prompt gammas emitting from the nuclear reactions of the proton beam in the patient are converted to electrons, and then the converted electrons are tracked to determine the vertices of the prompt gammas, thereby producing a 2D image of the vertices. In the present study, we developed a prototype GEVI system, including dedicated signal processing and data acquisition systems, which consists of a beryllium plate (= electron converter) to convert the prompt gammas to electrons, two double-sided silicon strip detectors (= hodoscopes) to determine the trajectories of those converted electrons, and a plastic scintillation detector (= calorimeter) to measure their kinetic energies. The system uses triple coincidence logic and multiple energy windows to select only the events from prompt gammas. The detectors of the prototype GEVI system were evaluated for electronic noise level, energy resolution, and time resolution. Finally, the imaging capability of the GEVI system was tested by imaging a {sup 90}Sr beta source, a {sup 60}Co gamma source, and a 45-MeV proton beam in a PMMA phantom. The overall results of the present study generally show that the prototype GEVI system can image the vertices of the prompt gammas produced by the proton nuclear interactions.

  2. Multiple-wavelength range-gated active imaging principle in the accumulation mode for three-dimensional imaging.

    Science.gov (United States)

    Matwyschuk, Alexis

    2017-01-20

    Having laid the foundations of the multiple-wavelength range-gated active imaging principle in flash mode in a previous paper, we have been studying its use in accumulation mode. Whatever the mode, the principle consists of restoring the 3D scene directly in a single image at the moment of recording with a camera. Each emitted light pulse with a different wavelength corresponds to a visualized zone with a different distance in the scene. So each of these visualized zones is identified by a different wavelength. In flash mode, the camera shutter opens just once during the emission of light pulses with the different wavelengths. However, the energy constraints to restore scenes in three dimensions can lead to a change in the recording mode when moving from the flash mode to the accumulation mode. In this mode, the cycle, including a series of light pulses with the used wavelengths and an aperture of the camera shutter, is repeated several times for a given image recorded with the intensified camera. Each wavelength always corresponds to a visualized slice with a different distance in the scene. So, the accumulation enables increasing the illumination of every visualized slice. The modeling conducted in the previous paper must be completed to adapt it to this mode. The tests with a multiple-wavelength laser source confirmed the quality improvement of the recorded images for more remote scenes and validated the principle of restoring, directly in a color image, the three dimensions of a scene.

  3. On the experimental validation of model-based dose calculation algorithms for 192Ir HDR brachytherapy treatment planning

    Science.gov (United States)

    Pappas, Eleftherios P.; Zoros, Emmanouil; Moutsatsos, Argyris; Peppa, Vasiliki; Zourari, Kyveli; Karaiskos, Pantelis; Papagiannis, Panagiotis

    2017-05-01

    There is an acknowledged need for the design and implementation of physical phantoms appropriate for the experimental validation of model-based dose calculation algorithms (MBDCA) introduced recently in 192Ir brachytherapy treatment planning systems (TPS), and this work investigates whether it can be met. A PMMA phantom was prepared to accommodate material inhomogeneities (air and Teflon), four plastic brachytherapy catheters, as well as 84 LiF TLD dosimeters (MTS-100M 1  ×  1  ×  1 mm3 microcubes), two radiochromic films (Gafchromic EBT3) and a plastic 3D dosimeter (PRESAGE). An irradiation plan consisting of 53 source dwell positions was prepared on phantom CT images using a commercially available TPS and taking into account the calibration dose range of each detector. Irradiation was performed using an 192Ir high dose rate (HDR) source. Dose to medium in medium, Dmm , was calculated using the MBDCA option of the same TPS as well as Monte Carlo (MC) simulation with the MCNP code and a benchmarked methodology. Measured and calculated dose distributions were spatially registered and compared. The total standard (k  =  1) spatial uncertainties for TLD, film and PRESAGE were: 0.71, 1.58 and 2.55 mm. Corresponding percentage total dosimetric uncertainties were: 5.4-6.4, 2.5-6.4 and 4.85, owing mainly to the absorbed dose sensitivity correction and the relative energy dependence correction (position dependent) for TLD, the film sensitivity calibration (dose dependent) and the dependencies of PRESAGE sensitivity. Results imply a LiF over-response due to a relative intrinsic energy dependence between 192Ir and megavoltage calibration energies, and a dose rate dependence of PRESAGE sensitivity at low dose rates (required for the full characterization of dosimeter response for 192Ir and the reduction of experimental uncertainties.

  4. Long-range non-contact imaging photoplethysmography: cardiac pulse wave sensing at a distance

    Science.gov (United States)

    Blackford, Ethan B.; Estepp, Justin R.; Piasecki, Alyssa M.; Bowers, Margaret A.; Klosterman, Samantha L.

    2016-03-01

    Non-contact, imaging photoplethysmography uses photo-optical sensors to measure variations in light absorption, caused by blood volume pulsations, to assess cardiopulmonary parameters including pulse rate, pulse rate variability, and respiration rate. Recently, researchers have studied the applications and methodology of imaging photoplethysmography. Basic research has examined some of the variables affecting data quality and accuracy of imaging photoplethysmography including signal processing, imager parameters (e.g. frame rate and resolution), lighting conditions, subject motion, and subject skin tone. This technology may be beneficial for long term or continuous monitoring where contact measurements may be harmful (e.g. skin sensitivities) or where imperceptible or unobtrusive measurements are desirable. Using previously validated signal processing methods, we examined the effects of imager-to-subject distance on one-minute, windowed estimates of pulse rate. High-resolution video of 22, stationary participants was collected using an enthusiast-grade, mirrorless, digital camera equipped with a fully-manual, super-telephoto lens at distances of 25, 50, and 100 meters with simultaneous contact measurements of electrocardiography, and fingertip photoplethysmography. By comparison, previous studies have usually been conducted with imager-to-subject distances of up to only a few meters. Mean absolute error for one-minute, windowed, pulse rate estimates (compared to those derived from gold-standard electrocardiography) were 2.0, 4.1, and 10.9 beats per minute at distances of 25, 50, and 100 meters, respectively. Long-range imaging presents several unique challenges among which include decreased, observed light reflectance and smaller regions of interest. Nevertheless, these results demonstrate that accurate pulse rate measurements can be obtained from over long imager-to-participant distances given these constraints.

  5. A new approach towards image based virtual 3D city modeling by using close range photogrammetry

    Science.gov (United States)

    Singh, S. P.; Jain, K.; Mandla, V. R.

    2014-05-01

    3D city model is a digital representation of the Earth's surface and it's related objects such as building, tree, vegetation, and some manmade feature belonging to urban area. The demand of 3D city modeling is increasing day to day for various engineering and non-engineering applications. Generally three main image based approaches are using for virtual 3D city models generation. In first approach, researchers used Sketch based modeling, second method is Procedural grammar based modeling and third approach is Close range photogrammetry based modeling. Literature study shows that till date, there is no complete solution available to create complete 3D city model by using images. These image based methods also have limitations This paper gives a new approach towards image based virtual 3D city modeling by using close range photogrammetry. This approach is divided into three sections. First, data acquisition process, second is 3D data processing, and third is data combination process. In data acquisition process, a multi-camera setup developed and used for video recording of an area. Image frames created from video data. Minimum required and suitable video image frame selected for 3D processing. In second section, based on close range photogrammetric principles and computer vision techniques, 3D model of area created. In third section, this 3D model exported to adding and merging of other pieces of large area. Scaling and alignment of 3D model was done. After applying the texturing and rendering on this model, a final photo-realistic textured 3D model created. This 3D model transferred into walk-through model or in movie form. Most of the processing steps are automatic. So this method is cost effective and less laborious. Accuracy of this model is good. For this research work, study area is the campus of department of civil engineering, Indian Institute of Technology, Roorkee. This campus acts as a prototype for city. Aerial photography is restricted in many country

  6. SINGLE IMAGE CAMERA CALIBRATION IN CLOSE RANGE PHOTOGRAMMETRY FOR SOLDER JOINT ANALYSIS

    Directory of Open Access Journals (Sweden)

    D. Heinemann

    2016-06-01

    Full Text Available Printed Circuit Boards (PCB play an important role in the manufacturing of electronic devices. To ensure a correct function of the PCBs a certain amount of solder paste is needed during the placement of components. The aim of the current research is to develop an real-time, closed-loop solution for the analysis of the printing process where solder is printed onto PCBs. Close range photogrammetry allows for determination of the solder volume and a subsequent correction if necessary. Photogrammetry is an image based method for three dimensional reconstruction from two dimensional image data of an object. A precise camera calibration is indispensable for an accurate reconstruction. In our certain application it is not possible to use calibration methods with two dimensional calibration targets. Therefore a special calibration target was developed and manufactured, which allows for single image camera calibration.

  7. CLOSE RANGE HYPERSPECTRAL IMAGING INTEGRATED WITH TERRESTRIAL LIDAR SCANNING APPLIED TO ROCK CHARACTERISATION AT CENTIMETRE SCALE

    Directory of Open Access Journals (Sweden)

    T. H. Kurz

    2012-07-01

    Full Text Available Compact and lightweight hyperspectral imagers allow the application of close range hyperspectral imaging with a ground based scanning setup for geological fieldwork. Using such a scanning setup, steep cliff sections and quarry walls can be scanned with a more appropriate viewing direction and a higher image resolution than from airborne and spaceborne platforms. Integration of the hyperspectral imagery with terrestrial lidar scanning provides the hyperspectral information in a georeferenced framework and enables measurement at centimetre scale. In this paper, three geological case studies are used to demonstrate the potential of this method for rock characterisation. Two case studies are applied to carbonate quarries where mapping of different limestone and dolomite types was required, as well as measurements of faults and layer thicknesses from inaccessible parts of the quarries. The third case study demonstrates the method using artificial lighting, applied in a subsurface scanning scenario where solar radiation cannot be utilised.

  8. Range image segmentation using Zernike moment-based generalized edge detector

    Science.gov (United States)

    Ghosal, S.; Mehrotra, R.

    1992-01-01

    The authors proposed a novel Zernike moment-based generalized step edge detection method which can be used for segmenting range and intensity images. A generalized step edge detector is developed to identify different kinds of edges in range images. These edge maps are thinned and linked to provide final segmentation. A generalized edge is modeled in terms of five parameters: orientation, two slopes, one step jump at the location of the edge, and the background gray level. Two complex and two real Zernike moment-based masks are required to determine all these parameters of the edge model. Theoretical noise analysis is performed to show that these operators are quite noise tolerant. Experimental results are included to demonstrate edge-based segmentation technique.

  9. High throughput holographic imaging-in-flow for the analysis of a wide plankton size range.

    Science.gov (United States)

    Yourassowsky, Catherine; Dubois, Frank

    2014-03-24

    We developed a Digital Holographic Microscope (DHM) working with a partial coherent source specifically adapted to perform high throughput recording of holograms of plankton organisms in-flow, in a size range of 3 µm-300 µm, which is of importance for this kind of applications. This wide size range is achieved with the same flow cell and with the same microscope magnification. The DHM configuration combines a high magnification with a large field of view and provides high-resolution intensity and quantitative phase images refocusing on high sample flow rate. Specific algorithms were developed to detect and extract automatically the particles and organisms present in the samples in order to build holograms of each one that are used for holographic refocusing and quantitative phase contrast imaging. Experimental results are shown and discussed.

  10. Fusion of Building Information and Range Imaging for Autonomous Location Estimation in Indoor Environments

    Directory of Open Access Journals (Sweden)

    Tobias K. Kohoutek

    2013-02-01

    Full Text Available We present a novel approach for autonomous location estimation and navigation in indoor environments using range images and prior scene knowledge from a GIS database (CityGML. What makes this task challenging is the arbitrary relative spatial relation between GIS and Time-of-Flight (ToF range camera further complicated by a markerless configuration. We propose to estimate the camera’s pose solely based on matching of GIS objects and their detected location in image sequences. We develop a coarse-to-fine matching strategy that is able to match point clouds without any initial parameters. Experiments with a state-of-the-art ToF point cloud show that our proposed method delivers an absolute camera position with decimeter accuracy, which is sufficient for many real-world applications (e.g., collision avoidance.

  11. Image analysis of gunshot residue on entry wounds. II--A statistical estimation of firing range.

    Science.gov (United States)

    Brown, H; Cauchi, D M; Holden, J L; Allen, F C; Cordner, S; Thatcher, P

    1999-03-29

    A statistical investigation of the relationship between firing range and the amount and distribution of gunshot residue (GSR), used automated image analysis (IA) to quantify GSR deposit resulting from firings into pig skin, from distances ranging between contact and 45 cm. Overall, for a Ruger .22 semi-automatic rifle using CCI solid point, high velocity ammunition, the total area of GSR deposit on the skin sections decreased in a non-linear fashion with firing range. More specifically there were significant differences in the amount of GSR deposited from shots fired at contact compared with shots fired from distances between 2.5 and 45 cm; and between shots fired from a distance of 20 cm or less, with shots fired at a distance of 30 cm or more. In addition, GSR particles were heavily concentrated in the wound tract only for contact and close range shots at 2.5 cm, while the particle distribution was more uniform between the wound tract and the skin surfaces for shots fired from distances greater than 2.5 cm. Consequently, for future scientific investigations of gunshot fatalities, once standards have been established for the weapon and ammunition type in question, image analysis quantification of GSR deposited in and around the gunshot wound may be capable of providing a reliable, statistical basis for estimating firing range.

  12. TRM4: Range performance model for electro-optical imaging systems

    Science.gov (United States)

    Keßler, Stefan; Gal, Raanan; Wittenstein, Wolfgang

    2017-05-01

    TRM4 is a commonly used model for assessing device and range performance of electro-optical imagers. The latest version, TRM4.v2, has been released by Fraunhofer IOSB of Germany in June 2016. While its predecessor, TRM3, was developed for thermal imagers, assuming blackbody targets and backgrounds, TRM4 extends the TRM approach to assess three imager categories: imagers that exploit emitted radiation (TRM4 category Thermal), reflected radiation (TRM4 category Visible/NIR/SWIR), and both emitted and reflected radiation (TRM4 category General). Performance assessment in TRM3 and TRM4 is based on the perception of standard four-bar test patterns, whether distorted by under-sampling or not. Spatial and sampling characteristics are taken into account by the Average Modulation at Optimum Phase (AMOP), which replaces the system MTF used in previous models. The Minimum Temperature Difference Perceived (MTDP) figure of merit was introduced in TRM3 for assessing the range performance of thermal imagers. In TRM4, this concept is generalized to the MDSP (Minimum Difference Signal Perceived), which can be applied to all imager categories. In this paper, we outline and discuss the TRM approach and pinpoint differences between TRM4 and TRM3. In addition, an overview of the TRM4 software and its functionality is given. Features newly introduced in TRM4, such as atmospheric turbulence, irradiation sources, and libraries are addressed. We conclude with an outlook on future work and the new module for intensified CCD cameras that is currently under development

  13. Subinteger Range-Bin Alignment Method for ISAR Imaging of Noncooperative Targets

    Directory of Open Access Journals (Sweden)

    F. Pérez-Martínez

    2010-01-01

    Full Text Available Inverse Synthetic Aperture Radar (ISAR is a coherent radar technique capable of generating images of noncooperative targets. ISAR may have better performance in adverse meteorological conditions than traditional imaging sensors. Unfortunately, ISAR images are usually blurred because of the relative motion between radar and target. To improve the quality of ISAR products, motion compensation is necessary. In this context, range-bin alignment is the first step for translational motion compensation. In this paper, we propose a subinteger range-bin alignment method based on envelope correlation and reference profiles. The technique, which makes use of a carefully designed optimization stage, is robust against noise, clutter, target scintillation, and error accumulation. It provides us with very fine translational motion compensation. Comparisons with state-of-the-art range-bin alignment methods are included and advantages of the proposal are highlighted. Simulated and live data from a high-resolution linear-frequency-modulated continuous-wave radar are included to perform the pertinent comparisons.

  14. 3D FACE RECOGNITION FROM RANGE IMAGES BASED ON CURVATURE ANALYSIS

    Directory of Open Access Journals (Sweden)

    Suranjan Ganguly

    2014-02-01

    Full Text Available In this paper, we present a novel approach for three-dimensional face recognition by extracting the curvature maps from range images. There are four types of curvature maps: Gaussian, Mean, Maximum and Minimum curvature maps. These curvature maps are used as a feature for 3D face recognition purpose. The dimension of these feature vectors is reduced using Singular Value Decomposition (SVD technique. Now from calculated three components of SVD, the non-negative values of ‘S’ part of SVD is ranked and used as feature vector. In this proposed method, two pair-wise curvature computations are done. One is Mean, and Maximum curvature pair and another is Gaussian and Mean curvature pair. These are used to compare the result for better recognition rate. This automated 3D face recognition system is focused in different directions like, frontal pose with expression and illumination variation, frontal face along with registered face, only registered face and registered face from different pose orientation across X, Y and Z axes. 3D face images used for this research work are taken from FRAV3D database. The pose variation of 3D facial image is being registered to frontal pose by applying one to all registration technique then curvature mapping is applied on registered face images along with remaining frontal face images. For the classification and recognition purpose five layer feed-forward back propagation neural network classifiers is used, and the corresponding result is discussed in section 4.

  15. Dwell time modulation restrictions do not necessarily improve treatment plan quality for prostate HDR brachytherapy.

    Science.gov (United States)

    Balvert, Marleen; Gorissen, Bram L; den Hertog, Dick; Hoffmann, Aswin L

    2015-01-21

    Inverse planning algorithms for dwell time optimisation in interstitial high-dose-rate (HDR) brachytherapy may produce solutions with large dwell time variations within catheters, which may result in undesirable selective high-dose subvolumes. Extending the dwell time optimisation model with a dwell time modulation restriction (DTMR) that limits dwell time differences between neighboring dwell positions has been suggested to eliminate this problem. DTMRs may additionally reduce the sensitivity for uncertainties in dwell positions that inevitably result from catheter reconstruction errors and afterloader source positioning inaccuracies. This study quantifies the reduction of high-dose subvolumes and the robustness against these uncertainties by applying a DTMR to template-based prostate HDR brachytherapy implants. Three different DTMRs were consecutively applied to a linear dose-based penalty model (LD) and a dose-volume based model (LDV), both obtained from literature. The models were solved with DTMR levels ranging from no restriction to uniform dwell times within catheters in discrete steps. Uncertainties were simulated on clinical cases using in-house developed software, and dose-volume metrics were calculated in each simulation. For the assessment of high-dose subvolumes, the dose homogeneity index (DHI) and the contiguous dose volume histogram were analysed. Robustness was measured by the improvement of the lowest D90% of the planning target volume (PTV) observed in the simulations. For (LD), a DTMR yields an increase in DHI of approximately 30% and reduces the size of the largest high-dose volume by 2-5 cc. However, this comes at a cost of a reduction in D90% of the PTV of 10%, which often implies that it drops below the desired minimum of 100%. For (LDV), none of the DTMRs were able to improve high-dose volume measures. DTMRs were not capable of improving robustness of PTV D90% against uncertainty in dwell positions for both models.

  16. An automated optimization tool for high-dose-rate (HDR) prostate brachytherapy with divergent needle pattern

    Science.gov (United States)

    Borot de Battisti, M.; Maenhout, M.; de Senneville, B. Denis; Hautvast, G.; Binnekamp, D.; Lagendijk, J. J. W.; van Vulpen, M.; Moerland, M. A.

    2015-10-01

    Focal high-dose-rate (HDR) for prostate cancer has gained increasing interest as an alternative to whole gland therapy as it may contribute to the reduction of treatment related toxicity. For focal treatment, optimal needle guidance and placement is warranted. This can be achieved under MR guidance. However, MR-guided needle placement is currently not possible due to space restrictions in the closed MR bore. To overcome this problem, a MR-compatible, single-divergent needle-implant robotic device is under development at the University Medical Centre, Utrecht: placed between the legs of the patient inside the MR bore, this robot will tap the needle in a divergent pattern from a single rotation point into the tissue. This rotation point is just beneath the perineal skin to have access to the focal prostate tumor lesion. Currently, there is no treatment planning system commercially available which allows optimization of the dose distribution with such needle arrangement. The aim of this work is to develop an automatic inverse dose planning optimization tool for focal HDR prostate brachytherapy with needle insertions in a divergent configuration. A complete optimizer workflow is proposed which includes the determination of (1) the position of the center of rotation, (2) the needle angulations and (3) the dwell times. Unlike most currently used optimizers, no prior selection or adjustment of input parameters such as minimum or maximum dose or weight coefficients for treatment region and organs at risk is required. To test this optimizer, a planning study was performed on ten patients (treatment volumes ranged from 8.5 cm3to 23.3 cm3) by using 2-14 needle insertions. The total computation time of the optimizer workflow was below 20 min and a clinically acceptable plan was reached on average using only four needle insertions.

  17. Dwell time modulation restrictions do not necessarily improve treatment plan quality for prostate HDR brachytherapy

    Science.gov (United States)

    Balvert, Marleen; Gorissen, Bram L.; den Hertog, Dick; Hoffmann, Aswin L.

    2015-01-01

    Inverse planning algorithms for dwell time optimisation in interstitial high-dose-rate (HDR) brachytherapy may produce solutions with large dwell time variations within catheters, which may result in undesirable selective high-dose subvolumes. Extending the dwell time optimisation model with a dwell time modulation restriction (DTMR) that limits dwell time differences between neighboring dwell positions has been suggested to eliminate this problem. DTMRs may additionally reduce the sensitivity for uncertainties in dwell positions that inevitably result from catheter reconstruction errors and afterloader source positioning inaccuracies. This study quantifies the reduction of high-dose subvolumes and the robustness against these uncertainties by applying a DTMR to template-based prostate HDR brachytherapy implants. Three different DTMRs were consecutively applied to a linear dose-based penalty model (LD) and a dose-volume based model (LDV), both obtained from literature. The models were solved with DTMR levels ranging from no restriction to uniform dwell times within catheters in discrete steps. Uncertainties were simulated on clinical cases using in-house developed software, and dose-volume metrics were calculated in each simulation. For the assessment of high-dose subvolumes, the dose homogeneity index (DHI) and the contiguous dose volume histogram were analysed. Robustness was measured by the improvement of the lowest D90% of the planning target volume (PTV) observed in the simulations. For (LD), a DTMR yields an increase in DHI of approximately 30% and reduces the size of the largest high-dose volume by 2-5 cc. However, this comes at a cost of a reduction in D90% of the PTV of 10%, which often implies that it drops below the desired minimum of 100%. For (LDV), none of the DTMRs were able to improve high-dose volume measures. DTMRs were not capable of improving robustness of PTV D90% against uncertainty in dwell positions for both models.

  18. SU-C-202-02: A Comprehensive Evaluation of Adaptive Daily Planning for Cervical Cancer HDR Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Meerschaert, R; Paul, A; Zhuang, L [Department of Oncology, Radiation Oncology Division, Wayne State University School of Medicine, Detroit, MI (United States); Nalichowski, A [Department of Oncology, Radiation Oncology Division, Karmanos Cancer Institute, Detroit, MI (United States); Burmeister, J; Miller, A [Department of Oncology, Radiation Oncology Division, Wayne State University School of Medicine, Detroit, MI (United States); Department of Oncology, Radiation Oncology Division, Karmanos Cancer Institute, Detroit, MI (United States)

    2016-06-15

    Purpose: To evaluate adaptive daily planning for cervical cancer patients who underwent high-dose-rate intra-cavitary brachytherapy (HDR-ICBT). Methods: This study included 22 cervical cancer patients who underwent 5 fractions of HDR ICBT. Regions of interest (ROIs) including high-risk clinical tumor volume (HR-CTV) and organs-at-risk (OARs) were manually contoured on daily CT images. All patients were treated with adaptive daily plans, which involved ROI delineation and dose optimization at each treatment fraction. Single treatment plans were retrospectively generated by applying the first treatment fraction’s dwell times adjusted for decay and dwell positions of the applicator to subsequent treatment fractions. Various existing similarity metrics were calculated for the ROIs to quantify interfractional organ variations. A novel similarity score (JRARM) was established, which combined both volumetric overlap metrics (DSC, JSC, and RVD) and distance metrics (ASD, MSD, and RMSD). Linear regression was performed to determine a relationship between inter-fractional organ variations of various similarity metrics and D2cc variations from both plans. Wilcoxon Signed Rank Tests were used to assess adaptive daily plans and single plans by comparing EQD2 D2cc (α/β=3) for OARs. Results: For inter-fractional organ variations, the sigmoid demonstrated the greatest variations based on the JRARM and DSC similarity metrics. Comparisons between paired ROIs showed differences in JRARM scores and DSCs at each treatment fraction. RVD, MSD, and RMSD were found to be significantly correlated to D2cc variations for bladder and sigmoid. The comparison between plans found that adaptive daily planning provided lower EQD2 D2cc of OARs than single planning, specifically for the sigmoid (p=0.015). Conclusion: Substantial inter-fractional organ motion can occur during HDR-BT, which may significantly affect D2cc of OARs. Adaptive daily planning provides improved dose sparing for OARs

  19. Observation and simulation of non-laminar flow phenomena at the HDR site near Soulth-sous-forets; Beobachtung und Simulation von nicht-laminarem Fliessverhalten am HDR-Standort Soultz

    Energy Technology Data Exchange (ETDEWEB)

    Kohl, T. [ETH Hoenggerberg, Zuerich (Switzerland). Inst. fuer Geophysik; Evans, K.F.; Hopkirk, R.J. [Polydynamics Engineering, Maennedorf (Switzerland); Jung, R. [Bundesanstalt fuer Geowissenschaften und Rohstoffe, Hannover (Germany); Rybach, L. [ETH Hoenggerberg, Zuerich (Switzerland). Inst. fuer Geophysik und Radiometrie

    1997-12-01

    Three independent multi-rate flow experiments were conducted in 1994 and 1995 in the open hole depth interval of a wellbore at the Hot-Dry-Rocks (HDR) test site Soultz. The steady state and transient dowmhole pressure records gave clear indications of non-Darcian flow. A numerical model has been set-up to evaluate these two measurements. An excellent fit of the transient pressure responses of all three flow tests could be achieved by assuming a simple model geometry. The models predict fluid transport along a conduit with substantial surface area in which fully-turbulent flow is occurring. The parameters required by our best-fit simulation all fall into a physically reasonable range. Sensitivity analysis demonstrates a non-Darcian flow regime along highly conductive features. The existence of high capacity far-field faults as postulated in our model confirms earlier characterisations of the Soultz test site. (orig.) [Deutsch] In den Jahren 1994 und 1995 wurden drei unabhaengige Druck- bzw. Fliessratentests in den Bohrungen GPK1 und GPK2 des HDR Standortes Soultz durchgefuehrt. Sowohl die stationaeren wie auch die instationaeren Druckaufzeichnungen gaben bereits klare Hinweise auf nichtlaminare, turbulent-aehnliche Stroemungsverhaeltnisse. Zur genaueren Interpretation dieser Daten wurde das numerische Programm FRACTure erweitert. Unter der Annahme eines geometrisch einfachen Modells konnten die instationaeren Druckantworten sehr gut angepasst werden. Es gelang sogar, die beiden in GPK1 durchgefuehrten Tests durch dieselben Modelle zu erklaeren. Die hierfuer benoetigten Modellparameter liegen in einem physikalisch sinnvollem Rahmen und bestaetigen z.T. fruehere Untersuchungen. Die Existenz grosser Stoerungszonen, welche von den Modellen vorausgesetzt werden, bestaetigt ebenfalls fruehere Charakterisierungen des HDR Standortes Soultz als ein teilweise offenes hydraulisches System. (orig.)

  20. Fluorescence imaging of viscous materials in the ultraviolet-visible wavelength range

    Energy Technology Data Exchange (ETDEWEB)

    Murr, Patrik J., E-mail: patrik.murr@tum.de; Rauscher, Markus S.; Tremmel, Anton; Schardt, Michael; Koch, Alexander W. [Institute for Measurement Systems and Sensor Technology, Technische Universität München, Theresienstraße 90, 80333 München (Germany)

    2014-08-15

    This paper presents an approach of an innovative measurement principle for the quality control of viscous materials during a manufacturing process based on fluorescence imaging. The main contribution to the state of the art provided by this measurement system is that three equal fluorescence images of a static or moving viscous object are available in different optical paths. The independent images are obtained by two beam splitters which are connected in series. Based on these images, it is possible to evaluate each image separately. In our case, three optical bandpass filters with different center wavelengths of 405 nm, 420 nm, and 440 nm were used to filter the separate fluorescence images. The developed system is useable for the detection of impurities in the micrometer range. Further, incorrect mixing ratios of particular components and wrong single components in the viscous materials can be detected with the setup. Moreover, it is possible to realize static and dynamic measurements. In this case the maximum speed of the objects was 0.2 m/s for the dynamic measurements. Advantages of this measurement setup are the universality due to the use of optical standard components, the small dimension and the opportunity to integrate it easily into ongoing processes. In addition, the measurement system works on a non-contact basis. Thus, the expense for maintenance is at a very low level compared to currently available measurement setups for the investigated application. Furthermore, the setup provides for the first time a simultaneous analysis of more than one component and the detection of impurities concerning their nature and size in a manufacturing process.

  1. Measurements of pulse rate using long-range imaging photoplethysmography and sunlight illumination outdoors

    Science.gov (United States)

    Blackford, Ethan B.; Estepp, Justin R.

    2017-02-01

    Imaging photoplethysmography, a method using imagers to record absorption variations caused by microvascular blood volume pulsations, shows promise as a non-contact cardiovascular sensing technology. The first long-range imaging photoplethysmography measurements at distances of 25, 50, and 100 meters from the participant was recently demonstrated. Degraded signal quality was observed with increasing imager-to-subject distances. The degradation in signal quality was hypothesized to be largely attributable to inadequate light return to the image sensor with increasing lens focal length. To test this hypothesis, a follow-up evaluation with 27 participants was conducted outdoors with natural sunlight illumination resulting in 5-33 times the illumination intensity. Video was recorded from cameras equipped with ultra-telephoto lenses and positioned at distances of 25, 50, 100, and 150 meters. The brighter illumination allowed high-definition video recordings at increased frame rates of 60fps, shorter exposure times, and lower ISO settings, leading to higher quality image formation than the previous indoor evaluation. Results were compared to simultaneous reference measurements from electrocardiography. Compared to the previous indoor study, we observed lower overall error in pulse rate measurement with the same pattern of degradation in signal quality with respect to increasing distance. This effect was corroborated by the signal-to-noise ratio of the blood volume pulse signal which also showed decreasing quality with respect to increasing distance. Finally, a popular chrominance-based method was compared to a blind source separation approach; while comparable in measurement of signal-to-noise ratio, we observed higher overall error in pulse rate measurement using the chrominance method in this data.

  2. Advanced Spectroscopic and Thermal Imaging Instrumentation for Shock Tube and Ballistic Range Facilities

    Science.gov (United States)

    Grinstead, Jay H.; Wilder, Michael C.; Reda, Daniel C.; Cruden, Brett A.; Bogdanoff, David W.

    2010-01-01

    The Electric Arc Shock Tube (EAST) facility and Hypervelocity Free Flight Aerodynamic Facility (HFFAF, an aeroballistic range) at NASA Ames support basic research in aerothermodynamic phenomena of atmospheric entry, specifically shock layer radiation spectroscopy, convective and radiative heat transfer, and transition to turbulence. Innovative optical instrumentation has been developed and implemented to meet the challenges posed from obtaining such data in these impulse facilities. Spatially and spectrally resolved measurements of absolute radiance of a travelling shock wave in EAST are acquired using multiplexed, time-gated imaging spectrographs. Nearly complete spectral coverage from the vacuum ultraviolet to the near infrared is possible in a single experiment. Time-gated thermal imaging of ballistic range models in flight enables quantitative, global measurements of surface temperature. These images can be interpreted to determine convective heat transfer rates and reveal transition to turbulence due to isolated and distributed surface roughness at hypersonic velocities. The focus of this paper is a detailed description of the optical instrumentation currently in use in the EAST and HFFAF.

  3. A low-noise wide dynamic range CMOS image sensor with low and high temperatures resistance

    Science.gov (United States)

    Mizobuchi, Koichi; Adachi, Satoru; Tejada, Jose; Oshikubo, Hiromichi; Akahane, Nana; Sugawa, Shigetoshi

    2008-02-01

    A temperature-resistant 1/3 inch SVGA (800×600 pixels) 5.6 μm pixel pitch wide-dynamic-range (WDR) CMOS image sensor has been developed using a lateral-over-flow-integration-capacitor (LOFIC) in a pixel. The sensor chips are fabricated through 0.18 μm 2P3M process with totally optimized front-end-of-line (FEOL) & back-end-of-line (BEOL) for a lower dark current. By implementing a low electrical field potential design for photodiodes, reducing damages, recovering crystal defects and terminating interface states in the FEOL+BEOL, the dark current is improved to 12 e - /pixel-sec at 60 deg.C with 50% reduction from the previous very-low-dark-current (VLDC) FEOL and its contribution to the temporal noise is improved. Furthermore, design optimizations of the readout circuits, especially a signal-and noise-hold circuit and a programmable-gain-amplifier (PGA) are also implemented. The measured temporal noise is 2.4 e -rms at 60 fps (:36 MHz operation). The dynamic-range (DR) is extended to 100 dB with 237 ke - full well capacity. In order to secure the temperature-resistance, the sensor chip also receives both an inorganic cap onto micro lens and a metal hermetic seal package assembly. Image samples at low & high temperatures show significant improvement in image qualities.

  4. PROCESSING OF UAV BASED RANGE IMAGING DATA TO GENERATE DETAILED ELEVATION MODELS OF COMPLEX NATURAL STRUCTURES

    Directory of Open Access Journals (Sweden)

    T. K. Kohoutek

    2012-07-01

    Full Text Available Unmanned Aerial Vehicles (UAVs are more and more used in civil areas like geomatics. Autonomous navigated platforms have a great flexibility in flying and manoeuvring in complex environments to collect remote sensing data. In contrast to standard technologies such as aerial manned platforms (airplanes and helicopters UAVs are able to fly closer to the object and in small-scale areas of high-risk situations such as landslides, volcano and earthquake areas and floodplains. Thus, UAVs are sometimes the only practical alternative in areas where access is difficult and where no manned aircraft is available or even no flight permission is given. Furthermore, compared to terrestrial platforms, UAVs are not limited to specific view directions and could overcome occlusions from trees, houses and terrain structures. Equipped with image sensors and/or laser scanners they are able to provide elevation models, rectified images, textured 3D-models and maps. In this paper we will describe a UAV platform, which can carry a range imaging (RIM camera including power supply and data storage for the detailed mapping and monitoring of complex structures, such as alpine riverbed areas. The UAV platform NEO from Swiss UAV was equipped with the RIM camera CamCube 2.0 by PMD Technologies GmbH to capture the surface structures. Its navigation system includes an autopilot. To validate the UAV-trajectory a 360° prism was installed and tracked by a total station. Within the paper a workflow for the processing of UAV-RIM data is proposed, which is based on the processing of differential GNSS data in combination with the acquired range images. Subsequently, the obtained results for the trajectory are compared and verified with a track of a UAV (Falcon 8, Ascending Technologies carried out with a total station simultaneously to the GNSS data acquisition. The results showed that the UAV's position using differential GNSS could be determined in the centimetre to the decimetre

  5. On the simulation and mitigation of anisoplanatic optical turbulence for long range imaging

    Science.gov (United States)

    Hardie, Russell C.; LeMaster, Daniel A.

    2017-05-01

    We describe a numerical wave propagation method for simulating long range imaging of an extended scene under anisoplanatic conditions. Our approach computes an array of point spread functions (PSFs) for a 2D grid on the object plane. The PSFs are then used in a spatially varying weighted sum operation, with an ideal image, to produce a simulated image with realistic optical turbulence degradation. To validate the simulation we compare simulated outputs with the theoretical anisoplanatic tilt correlation and differential tilt variance. This is in addition to comparing the long- and short-exposure PSFs, and isoplanatic angle. Our validation analysis shows an excellent match between the simulation statistics and the theoretical predictions. The simulation tool is also used here to quantitatively evaluate a recently proposed block- matching and Wiener filtering (BMWF) method for turbulence mitigation. In this method block-matching registration algorithm is used to provide geometric correction for each of the individual input frames. The registered frames are then averaged and processed with a Wiener filter for restoration. A novel aspect of the proposed BMWF method is that the PSF model used for restoration takes into account the level of geometric correction achieved during image registration. This way, the Wiener filter is able fully exploit the reduced blurring achieved by registration. The BMWF method is relatively simple computationally, and yet, has excellent performance in comparison to state-of-the-art benchmark methods.

  6. Automatic grading of appearance retention of carpets using intensity and range images

    Science.gov (United States)

    Orjuela Vargas, Sergio Alejandro; Ortiz-Jaramillo, Benhur; Vansteenkiste, Ewout; Rooms, Filip; De Meulemeester, Simon; de Keyser, Robain; Van Langenhove, Lieva; Philips, Wilfried

    2012-04-01

    Textiles are mainly used for decoration and protection. In both cases, their original appearance and its retention are important factors for customers. Therefore, evaluation of appearance parameters are critical for quality assurance purposes, during and after manufacturing, to determine the lifetime and/or beauty of textile products. In particular, appearance retention of textile products is commonly certified with grades, which are currently assigned by human experts. However, manufacturers would prefer a more objective system. We present an objective system for grading appearance retention, particularly, for textile floor coverings. Changes in appearance are quantified by using linear regression models on texture features extracted from intensity and range images. Range images are obtained by our own laser scanner, reconstructing the carpet surface using two methods that have been previously presented. We extract texture features using a variant of the local binary pattern technique based on detecting those patterns whose frequencies are related to the appearance retention grades. We test models for eight types of carpets. Results show that the proposed approach describes the degree of wear with a precision within the range allowed to human inspectors by international standards. The methodology followed in this experiment has been designed to be general for evaluating global deviation of texture in other types of textiles, as well as other surface materials.

  7. An Analog Gamma Correction Scheme for High Dynamic Range CMOS Logarithmic Image Sensors

    Science.gov (United States)

    Cao, Yuan; Pan, Xiaofang; Zhao, Xiaojin; Wu, Huisi

    2014-01-01

    In this paper, a novel analog gamma correction scheme with a logarithmic image sensor dedicated to minimize the quantization noise of the high dynamic applications is presented. The proposed implementation exploits a non-linear voltage-controlled-oscillator (VCO) based analog-to-digital converter (ADC) to perform the gamma correction during the analog-to-digital conversion. As a result, the quantization noise does not increase while the same high dynamic range of logarithmic image sensor is preserved. Moreover, by combining the gamma correction with the analog-to-digital conversion, the silicon area and overall power consumption can be greatly reduced. The proposed gamma correction scheme is validated by the reported simulation results and the experimental results measured for our designed test structure, which is fabricated with 0.35 μm standard complementary-metal-oxide-semiconductor (CMOS) process. PMID:25517692

  8. CT scan range estimation using multiple body parts detection: let PACS learn the CT image content.

    Science.gov (United States)

    Wang, Chunliang; Lundström, Claes

    2016-02-01

    The aim of this study was to develop an efficient CT scan range estimation method that is based on the analysis of image data itself instead of metadata analysis. This makes it possible to quantitatively compare the scan range of two studies. In our study, 3D stacks are first projected to 2D coronal images via a ray casting-like process. Trained 2D body part classifiers are then used to recognize different body parts in the projected image. The detected candidate regions go into a structure grouping process to eliminate false-positive detections. Finally, the scale and position of the patient relative to the projected figure are estimated based on the detected body parts via a structural voting. The start and end lines of the CT scan are projected to a standard human figure. The position readout is normalized so that the bottom of the feet represents 0.0, and the top of the head is 1.0. Classifiers for 18 body parts were trained using 184 CT scans. The final application was tested on 136 randomly selected heterogeneous CT scans. Ground truth was generated by asking two human observers to mark the start and end positions of each scan on the standard human figure. When compared with the human observers, the mean absolute error of the proposed method is 1.2% (max: 3.5%) and 1.6% (max: 5.4%) for the start and end positions, respectively. We proposed a scan range estimation method using multiple body parts detection and relative structure position analysis. In our preliminary tests, the proposed method delivered promising results.

  9. A compact, short-pulse laser for near-field, range-gated imaging

    Energy Technology Data Exchange (ETDEWEB)

    Zutavern, F.J.; Helgeson, W.D.; Loubriel, G.M. [Sandia National Labs., Albuquerque, NM (United States); Yates, G.J.; Gallegos, R.A.; McDonald, T.E. [Los Alamos National Lab., NM (United States)

    1996-12-31

    This paper describes a compact laser, which produces high power, wide-angle emission for a near-field, range-gated, imaging system. The optical pulses are produced by a 100 element laser diode array (LDA) which is pulsed with a GaAs, photoconductive semiconductor switch (PCSS). The LDA generates 100 ps long, gain-switched, optical pulses at 904 nm when it is driven with 3 ns, 400 A, electrical pulses from a high gain PCSS. Gain switching is facilitated with this many lasers by using a low impedance circuit to drive an array of lasers, which are connected electrically in series. The total optical energy produced per pulse is 10 microjoules corresponding to a total peak power of 100 kW. The entire laser system, including prime power (a nine volt battery), pulse charging, PCSS, and LDA, is the size of a small, hand-held flashlight. System lifetime, which is presently limited by the high gain PCSS, is an active area of research and development. Present limitations and potential improvements will be discussed. The complete range-gated imaging system is based on complementary technologies: high speed optical gating with intensified charge coupled devices (ICCD) developed at Los Alamos National Laboratory (LANL) and high gain, PCSS-driven LDAs developed at Sandia National Laboratories (SNL). The system is designed for use in highly scattering media such as turbid water or extremely dense fog or smoke. The short optical pulses from the laser and high speed gating of the ICCD are synchronized to eliminate the back-scattered light from outside the depth of the field of view (FOV) which may be as short as a few centimeters. A high speed photodiode can be used to trigger the intensifier gate and set the range-gated FOV precisely on the target. The ICCD and other aspects of the imaging system are discussed in a separate paper.

  10. 3D imaging by fast deconvolution algorithm in short-range UWB radar for concealed weapon detection

    NARCIS (Netherlands)

    Savelyev, T.; Yarovoy, A.

    2013-01-01

    A fast imaging algorithm for real-time use in short-range (ultra-wideband) radar with synthetic or real-array aperture is proposed. The reflected field is presented here as a convolution of the target reflectivity and point spread function (PSF) of the imaging system. To obtain a focused 3D image,

  11. A low-power high dynamic range front-end ASIC for imaging calorimeters

    CERN Document Server

    Bagliesi, M G; Marrocchesi, P S; Meucci, M; Millucci, V; Morsani, F; Paoletti, R; Pilo, F; Scribano, A; Turini, N; Valle, G D

    2002-01-01

    High granularity calorimeters with shower imaging capabilities require dedicated front-end electronics. The ICON 4CH and VA4 PMT chip-set is suitable for very high dynamic range systems with strict noise requirements. The ICON 4CH is a 4 channel input, 12 channel output ASIC designed for use in a multi-anode photomultiplier system with very large dynamic range and low-noise requirements. Each of the four input signals to the ASIC is split equally into three branches by a current conveyor. Each of the three branches is scaled differently: 1:1, 1:8 and 1:80. The signal is read out by a 12 channel low noise/low power high dynamic range charge sensitive preamplifier-shaper circuit (VA4-PMT chip), with simultaneous sample- and-hold, multiplexed analog read-out, calibration facilities. Tests performed in our lab with a PMT are reported in terms of linearity, dynamic range and cross-talk of the system. (5 refs).

  12. Application of lidar techniques to time-of-flight range imaging.

    Science.gov (United States)

    Whyte, Refael; Streeter, Lee; Cree, Michael J; Dorrington, Adrian A

    2015-11-20

    Amplitude-modulated continuous wave (AMCW) time-of-flight (ToF) range imaging cameras measure distance by illuminating the scene with amplitude-modulated light and measuring the phase difference between the transmitted and reflected modulation envelope. This method of optical range measurement suffers from errors caused by multiple propagation paths, motion, phase wrapping, and nonideal amplitude modulation. In this paper a ToF camera is modified to operate in modes analogous to continuous wave (CW) and stepped frequency continuous wave (SFCW) lidar. In CW operation the velocity of objects can be measured. CW measurement of velocity was linear with true velocity (R2=0.9969). Qualitative analysis of a complex scene confirms that range measured by SFCW is resilient to errors caused by multiple propagation paths, phase wrapping, and nonideal amplitude modulation which plague AMCW operation. In viewing a complicated scene through a translucent sheet, quantitative comparison of AMCW with SFCW demonstrated a reduction in the median error from -1.3  m to -0.06  m with interquartile range of error reduced from 4.0 m to 0.18 m.

  13. Surface wave effects on long range IR imaging in the marine surface layer

    Science.gov (United States)

    Francius, M. J.; Kunz, G. J.; van Eijk, A. M. J.

    2005-08-01

    The quality of long range infrared (IR) imaging depends on the effects of atmospheric refraction and other pathintegrated effects (e.g., transmission losses, scintillation and blurring), which are strongly related to the prevailing meteorological conditions. EOSTAR is a PC based computer program to quantify these strong nonlinear effects in the marine atmospheric surface layer and to present a spectrally resolved target image influenced by atmospheric effects using ray tracing techniques for the individual camera pixels. Presently, the propagation is predicted with bulk atmospheric models and the sea surface is idealized by steady regular periodic Stokes' waves. Dynamical wind-waves interactions are not taken into account in this approach, although they may strongly modify the refractive index in the near-surface layer. Nonetheless, the inclusion of the sea surface in the ray tracer module already has a great impact on the near-surface grazing rays and thus influences the images especially in situations of super refraction and mirage. This work aims at improving the description of the sea surface in EOSTAR taking into account the non-uniformity of spatially resolved wind-generated waves and swell. A new surface module is developed to model surface wind-waves and swell in EOSTAR on the basis of meteorological observations and spectral wave modeling. Effects due to these new surfaces will be analyzed and presented.

  14. Range imaging observations of PMSE using the EISCAT VHF radar: Phase calibration and first results

    Directory of Open Access Journals (Sweden)

    J. R. Fernandez

    2005-01-01

    Full Text Available A novel phase calibration technique for use with the multiple-frequency Range IMaging (RIM technique is introduced based on genetic algorithms. The method is used on data collected with the European Incoherent SCATter (EISCAT VHF radar during a 2002 experiment with the goal of characterizing the vertical structure of Polar Mesosphere Summer Echoes (PMSE over northern Norway. For typical Doppler measurements, the initial phases of the transmitter and receiver are not required to be the same. The EISCAT receiver systems exploit this fact, allowing a multi-static configuration. However, the RIM method relies on the small phase differences between closely spaced frequencies. As a result, the high-resolution images produced by the RIM method can be significantly degraded if not properly calibrated. Using an enhanced numerical radar simulator, in which data from multiple sampling volumes are simultaneously generated, the proposed calibration method is validated. Subsequently, the method is applied to preliminary data from the EISCAT radar, providing first results of RIM images of PMSE. Data using conventional analysis techniques, and confirmed by RIM, reveal an often-observed double-layer structure with higher stability in the lower layer. Moreover, vertical velocity oscillations exhibit a clear correlation with the apparent motion of the layers shown in the echo power plots.

  15. Monitoring glacier variations in the Urubamba and Vilcabamba Mountain Ranges, Peru, using "Landsat 5" images

    Science.gov (United States)

    Suarez, Wilson; Cerna, Marcos; Ordoñez, Julio; Frey, Holger; Giráldez, Claudia; Huggel, Christian

    2013-04-01

    The Urubamba and Vilcabamba mountain ranges are two geological structures belonging to the Andes in the southern part of Peru, which is located in the tropical region. These mountain ranges are especially located within the transition area between the Amazon region (altitudes close to 1'000 m a.s.l.) and the Andes. These mountains, with a maximum height of 6'280 m a.s.l. (Salkantay Snow Peak in the Vilcabamba range), are characterized by glaciers mainly higher than 5000 m a.s.l. Here we present a study on the evolution of the ice cover based on "Landsat 5" images from 1991 and 2011 is presented in this paper. These data are freely available from the USGS in a georeferenced format and cover a time span of more than 25 years. The glacier mapping is based on the Normalized Difference Snow Index (NDSI). In 1991 the Vilcabamba mountain range had 221 km2 of glacier cover, being reduced to 116.4 km2 in 2011, which represents a loss of 48%. In the Urubamba mountain range, the total glacier area was 64.9 km2 in 1991 and 29.4 km2 in 2011, representing a loss of 54.7%. It means that the glacier area was halved during the past two decades although precipitation patterns show an increase in recent years (the wet season lasts from September to April with precipitation peaks in February and March). Glacier changes in these two tropical mountain ranges also impact from an economic point of view due to small local farming common in this region (use of water from the melting glacier). Furthermore, potential glacier related hazards can pose a threat to people and infrastructure in the valleys below these glaciers, where the access routes to Machu Picchu Inca City, Peru's main tourist destination, are located too.

  16. Full Waveform Analysis for Long-Range 3D Imaging Laser Radar

    Directory of Open Access Journals (Sweden)

    Wallace AndrewM

    2010-01-01

    Full Text Available The new generation of 3D imaging systems based on laser radar (ladar offers significant advantages in defense and security applications. In particular, it is possible to retrieve 3D shape information directly from the scene and separate a target from background or foreground clutter by extracting a narrow depth range from the field of view by range gating, either in the sensor or by postprocessing. We discuss and demonstrate the applicability of full-waveform ladar to produce multilayer 3D imagery, in which each pixel produces a complex temporal response that describes the scene structure. Such complexity caused by multiple and distributed reflection arises in many relevant scenarios, for example in viewing partially occluded targets, through semitransparent materials (e.g., windows and through distributed reflective media such as foliage. We demonstrate our methodology on 3D image data acquired by a scanning time-of-flight system, developed in our own laboratories, which uses the time-correlated single-photon counting technique.

  17. SU-F-T-65: AutomaticTreatment Planning for High-Dose Rate (HDR) Brachytherapy with a VaginalCylinder Applicator

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Y; Tan, J; Jiang, S; Albuquerque, K; Jia, X [UT Southwestern Medical Center, Dallas, TX (United States)

    2016-06-15

    Purpose: High dose rate (HDR) brachytherapy treatment planning is conventionally performed in a manual fashion. Yet it is highly desirable to perform computerized automated planning to improve treatment planning efficiency, eliminate human errors, and reduce plan quality variation. The goal of this research is to develop an automatic treatment planning tool for HDR brachytherapy with a cylinder applicator for vaginal cancer. Methods: After inserting the cylinder applicator into the patient, a CT scan was acquired and was loaded to an in-house developed treatment planning software. The cylinder applicator was automatically segmented using image-processing techniques. CTV was generated based on user-specified treatment depth and length. Locations of relevant points (apex point, prescription point, and vaginal surface point), central applicator channel coordinates, and dwell positions were determined according to their geometric relations with the applicator. Dwell time was computed through an inverse optimization process. The planning information was written into DICOM-RT plan and structure files to transfer the automatically generated plan to a commercial treatment planning system for plan verification and delivery. Results: We have tested the system retrospectively in nine patients treated with vaginal cylinder applicator. These cases were selected with different treatment prescriptions, lengths, depths, and cylinder diameters to represent a large patient population. Our system was able to generate treatment plans for these cases with clinically acceptable quality. Computation time varied from 3–6 min. Conclusion: We have developed a system to perform automated treatment planning for HDR brachytherapy with a cylinder applicator. Such a novel system has greatly improved treatment planning efficiency and reduced plan quality variation. It also served as a testbed to demonstrate the feasibility of automatic HDR treatment planning for more complicated cases.

  18. Automatic Level Control for Video Cameras towards HDR Techniques

    Directory of Open Access Journals (Sweden)

    de With PeterHN

    2010-01-01

    Full Text Available We give a comprehensive overview of the complete exposure processing chain for video cameras. For each step of the automatic exposure algorithm we discuss some classical solutions and propose their improvements or give new alternatives. We start by explaining exposure metering methods, describing types of signals that are used as the scene content descriptors as well as means to utilize these descriptors. We also discuss different exposure control types used for the control of lens, integration time of the sensor, and gain control, such as a PID control, precalculated control based on the camera response function, and propose a new recursive control type that matches the underlying image formation model. Then, a description of commonly used serial control strategy for lens, sensor exposure time, and gain is presented, followed by a proposal of a new parallel control solution that integrates well with tone mapping and enhancement part of the image pipeline. Parallel control strategy enables faster and smoother control and facilitates optimally filling the dynamic range of the sensor to improve the SNR and an image contrast, while avoiding signal clipping. This is archived by the proposed special control modes used for better display and correct exposure of both low-dynamic range and high-dynamic range images. To overcome the inherited problems of limited dynamic range of capturing devices we discuss a paradigm of multiple exposure techniques. Using these techniques we can enable a correct rendering of difficult class of high-dynamic range input scenes. However, multiple exposure techniques bring several challenges, especially in the presence of motion and artificial light sources such as fluorescent lights. In particular, false colors and light-flickering problems are described. After briefly discussing some known possible solutions for the motion problem, we focus on solving the fluorescence-light problem. Thereby, we propose an algorithm for

  19. Applications of the Integrated High-Performance CMOS Image Sensor to Range Finders - from Optical Triangulation to the Automotive Field.

    Science.gov (United States)

    Wu, Jih-Huah; Pen, Cheng-Chung; Jiang, Joe-Air

    2008-03-13

    With their significant features, the applications of complementary metal-oxidesemiconductor (CMOS) image sensors covers a very extensive range, from industrialautomation to traffic applications such as aiming systems, blind guidance, active/passiverange finders, etc. In this paper CMOS image sensor-based active and passive rangefinders are presented. The measurement scheme of the proposed active/passive rangefinders is based on a simple triangulation method. The designed range finders chieflyconsist of a CMOS image sensor and some light sources such as lasers or LEDs. Theimplementation cost of our range finders is quite low. Image processing software to adjustthe exposure time (ET) of the CMOS image sensor to enhance the performance oftriangulation-based range finders was also developed. An extensive series of experimentswere conducted to evaluate the performance of the designed range finders. From theexperimental results, the distance measurement resolutions achieved by the active rangefinder and the passive range finder can be better than 0.6% and 0.25% within themeasurement ranges of 1 to 8 m and 5 to 45 m, respectively. Feasibility tests onapplications of the developed CMOS image sensor-based range finders to the automotivefield were also conducted. The experimental results demonstrated that our range finders arewell-suited for distance measurements in this field.

  20. Initial Comparison of the Lightning Imaging Sensor (LIS) with Lightning Detection and Ranging (LDAR)

    Science.gov (United States)

    Ushio, Tomoo; Driscoll, Kevin; Heckman, Stan; Boccippio, Dennis; Koshak, William; Christian, Hugh

    1999-01-01

    The mapping of the lightning optical pulses detected by the Lightning Imaging Sensor (LIS) is compared with the radiation sources by Lightning Detection and Ranging (LDAR) and the National Lightning Detection Network (NLDN) for three thunderstorms observed during and overpasses on 15 August 1998. The comparison involves 122 flashes including 42 ground and 80 cloud flashes. For ground flash, the LIS recorded the subsequent strokes and changes inside the cloud. For cloud flashes, LIS recorded those with higher sources in altitude and larger number of sources. The discrepancies between the LIS and LDAR flash locations are about 4.3 km for cloud flashes and 12.2 km for ground flashes. The reason for these differences remain a mystery.

  1. Design and fabrication of the New Horizons Long-Range Reconnaissance Imager

    Science.gov (United States)

    Conard, S. J.; Azad, F.; Boldt, J. D.; Cheng, A.; Cooper, K. A.; Darlington, E. H.; Grey, M. P.; Hayes, J. R.; Hogue, P.; Kosakowski, K. E.; Magee, T.; Morgan, M. F.; Rossano, E.; Sampath, D.; Schlemm, C.; Weaver, H. A.

    2005-09-01

    The LOng-Range Reconnaissance Imager (LORRI) is an instrument that was designed, fabricated, and qualified for the New Horizons mission to the outermost planet Pluto, its giant satellite Charon, and the Kuiper Belt, which is the vast belt of icy bodies extending roughly from Neptune's orbit out to 50 astronomical units (AU). New Horizons is being prepared for launch in January 2006 as the inaugural mission in NASA's New Frontiers program. This paper provides an overview of the efforts to produce LORRI. LORRI is a narrow angle (field of view=0.29°), high resolution (instantaneous field of view = 4.94 μrad), Ritchey-Chretien telescope with a 20.8 cm diameter primary mirror, a focal length of 263 cm, and a three lens field-flattening assembly. A 1024 x 1024 pixel (optically active region), back-thinned, backside-illuminated charge-coupled device (CCD) detector (model CCD 47-20 from E2V Technologies) is located at the telescope focal plane and is operated in standard frame-transfer mode. LORRI does not have any color filters; it provides panchromatic imaging over a wide bandpass that extends approximately from 350 nm to 850 nm. A unique aspect of LORRI is the extreme thermal environment, as the instrument is situated inside a near room temperature spacecraft, while pointing primarily at cold space. This environment forced the use of a silicon carbide optical system, which is designed to maintain focus over the operating temperature range without a focus adjustment mechanism. Another challenging aspect of the design is that the spacecraft will be thruster stabilized (no reaction wheels), which places stringent limits on the available exposure time and the optical throughput needed to accomplish the high-resolution observations required. LORRI was designed and fabricated by a combined effort of The Johns Hopkins University Applied Physics Laboratory (APL) and SSG Precision Optronics Incorporated (SSG).

  2. Study of the workload to be applied in the shielding calculation in HDR brachytherapy facilities with IR-192; Estudio de la carga de trabajo a aplicar en el calculo de blindajes en instalaciones de braquiterapia HDR con IR-192

    Energy Technology Data Exchange (ETDEWEB)

    Pujades-Clamarchirant, M. C.; Perez-Calatayud, J.; Ballester, F.; Gimeno, J.; Granero, D.; Camacho, C.; Carmona, V.; Lliso, F.; Vijande, J.

    2011-07-01

    The design of shielding facilities high rate brachytherapy (HDR) requires an estimate of the workload (w) . The aim of this study was to evaluate the W typical service HDR BT with a high number of applications and their impact on the final thickness the shielding of the room. To do this, a review of patients treated in our center HDR W has been evaluated and studied their impact on the shielding design of the facility.

  3. Low-complexity Compression of High Dynamic Range Infrared Images with JPEG compatibility

    DEFF Research Database (Denmark)

    Belyaev, Evgeny; Mantel, Claire; Forchhammer, Søren

    2017-01-01

    data size, then we include the raw residual image instead. If the residual image contains only zero values or the quality factor for it is 0 then we do not include the residual image into the header. Experimental results show that compared with JPEG-XT Part 6 with ’global Reinhard’ tone-mapping....... Then we compress each image by a JPEG baseline encoder and include the residual image bit stream into the application part of JPEG header of the base image. As a result, the base image can be reconstructed by JPEG baseline decoder. If the JPEG bit stream size of the residual image is higher than the raw...

  4. NPIP: A skew line needle configuration optimization system for HDR brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Siauw, Timmy; Cunha, Adam; Berenson, Dmitry; Atamtuerk, Alper; Hsu, I-Chow; Goldberg, Ken; Pouliot, Jean [Department of Civil and Environmental Engineering, University of California, Berkeley, 760 Davis Hall, Berkeley, California 94720-1710 (United States); Department of Radiation Oncology, University of California, San Francisco, Comprehensive Cancer Center, 1600 Divisadero Street, Suite H1031, San Francisco, California 94143-1708 (United States); Department of Electrical Engineering and Computer Science, University of California, Berkeley, 4th Floor Sutardja Dai Hall, Berkeley, California 94720-1764 (United States); Department of Industrial Engineering and Operations, University of California, Berkeley, 4141 Etcheverry Hall, Berkeley, California 94720-1777 (United States); Department of Radiation Oncology, University of California, San Francisco, Comprehensive Cancer Center, 1600 Divisadero Street, Suite H1031, San Francisco, California 94143-1708 (United States); Department of Industrial Engineering and Operations Research and Department of Electrical Engineering and Computer Science, University of California, Berkeley, 4141 Etcheverry Hall, Berkeley, California 94720-1777 (United States); Department of Radiation Oncology, University of California, San Francisco, Comprehensive Cancer Center, 1600 Divisadero Street, Suite H1031, San Francisco, California 94143-1708 (United States)

    2012-07-15

    Purpose: In this study, the authors introduce skew line needle configurations for high dose rate (HDR) brachytherapy and needle planning by integer program (NPIP), a computational method for generating these configurations. NPIP generates needle configurations that are specific to the anatomy of the patient, avoid critical structures near the penile bulb and other healthy structures, and avoid needle collisions inside the body. Methods: NPIP consisted of three major components: a method for generating a set of candidate needles, a needle selection component that chose a candidate needle subset to be inserted, and a dose planner for verifying that the final needle configuration could meet dose objectives. NPIP was used to compute needle configurations for prostate cancer data sets from patients previously treated at our clinic. NPIP took two user-parameters: a number of candidate needles, and needle coverage radius, {delta}. The candidate needle set consisted of 5000 needles, and a range of {delta} values was used to compute different needle configurations for each patient. Dose plans were computed for each needle configuration. The number of needles generated and dosimetry were analyzed and compared to the physician implant. Results: NPIP computed at least one needle configuration for every patient that met dose objectives, avoided healthy structures and needle collisions, and used as many or fewer needles than standard practice. These needle configurations corresponded to a narrow range of {delta} values, which could be used as default values if this system is used in practice. The average end-to-end runtime for this implementation of NPIP was 286 s, but there was a wide variation from case to case. Conclusions: The authors have shown that NPIP can automatically generate skew line needle configurations with the aforementioned properties, and that given the correct input parameters, NPIP can generate needle configurations which meet dose objectives and use as many

  5. Discrimination between Sedimentary Rocks from Close-Range Visible and Very-Near-Infrared Images.

    Directory of Open Access Journals (Sweden)

    Susana Del Pozo

    Full Text Available Variation in the mineral composition of rocks results in a change of their spectral response capable of being studied by imaging spectroscopy. This paper proposes the use of a low-cost handy sensor, a calibrated visible-very near infrared (VIS-VNIR multispectral camera for the recognition of different geological formations. The spectral data was recorded by a Tetracam Mini-MCA-6 camera mounted on a field-based platform covering six bands in the spectral range of 0.530-0.801 µm. Twelve sedimentary formations were selected in the Rhône-Alpes region (France to analyse the discrimination potential of this camera for rock types and close-range mapping applications. After proper corrections and data processing, a supervised classification of the multispectral data was performed trying to distinguish four classes: limestones, marlstones, vegetation and shadows. After a maximum-likelihood classification, results confirmed that this camera can be efficiently exploited to map limestone-marlstone alternations in geological formations with this mineral composition.

  6. Study for online range monitoring with the interaction vertex imaging method

    Science.gov (United States)

    Finck, Ch; Karakaya, Y.; Reithinger, V.; Rescigno, R.; Baudot, J.; Constanzo, J.; Juliani, D.; Krimmer, J.; Rinaldi, I.; Rousseau, M.; Testa, E.; Vanstalle, M.; Ray, C.

    2017-12-01

    Ion beam therapy enables a highly accurate dose conformation delivery to the tumor due to the finite range of charged ions in matter (i.e. Bragg peak (BP)). Consequently, the dose profile is very sensitive to patients anatomical changes as well as minor mispositioning, and so it requires improved dose control techniques. Proton interaction vertex imaging (IVI) could offer an online range control in carbon ion therapy. In this paper, a statistical method was used to study the sensitivity of the IVI technique on experimental data obtained from the Heidelberg Ion-Beam Therapy Center. The vertices of secondary protons were reconstructed with pixelized silicon detectors. The statistical study used the χ2 test of the reconstructed vertex distributions for a given displacement of the BP position as a function of the impinging carbon ions. Different phantom configurations were used with or without bone equivalent tissue and air inserts. The inflection points in the fall-off region of the longitudinal vertex distribution were computed using different methods, while the relation with the BP position was established. In the present setup, the resolution of the BP position was about 4–5 mm in the homogeneous phantom under clinical conditions (106 incident carbon ions). Our results show that the IVI method could therefore monitor the BP position with a promising resolution in clinical conditions.

  7. Discrimination between Sedimentary Rocks from Close-Range Visible and Very-Near-Infrared Images.

    Science.gov (United States)

    Del Pozo, Susana; Lindenbergh, Roderik; Rodríguez-Gonzálvez, Pablo; Kees Blom, Jan; González-Aguilera, Diego

    2015-01-01

    Variation in the mineral composition of rocks results in a change of their spectral response capable of being studied by imaging spectroscopy. This paper proposes the use of a low-cost handy sensor, a calibrated visible-very near infrared (VIS-VNIR) multispectral camera for the recognition of different geological formations. The spectral data was recorded by a Tetracam Mini-MCA-6 camera mounted on a field-based platform covering six bands in the spectral range of 0.530-0.801 µm. Twelve sedimentary formations were selected in the Rhône-Alpes region (France) to analyse the discrimination potential of this camera for rock types and close-range mapping applications. After proper corrections and data processing, a supervised classification of the multispectral data was performed trying to distinguish four classes: limestones, marlstones, vegetation and shadows. After a maximum-likelihood classification, results confirmed that this camera can be efficiently exploited to map limestone-marlstone alternations in geological formations with this mineral composition.

  8. Characterization of commercial MOSFET detectors and their feasibility for in-vivo HDR brachytherapy.

    Science.gov (United States)

    Phurailatpam, Reena; Upreti, Rituraj; Nojin Paul, Siji; Jamema, Swamidas V; Deshpande, Deepak D

    2016-01-01

    The present study was to investigate the use of MOSFET as an vivo dosimeter for the application of Ir-192 HDR brachytherapy treatments. MOSFET was characterized for dose linearity in the range of 50-1000 cGy, depth dose dependence from 2 to 7 cm, angular dependence. Signal fading was checked for two weeks. Dose linearity was found to be within 2% in the dose range (50-1000 cGy). The response varied within 8.07% for detector-source distance of 2-7 cm. The response of MOSFET with the epoxy side facing the source (0 degree) is the highest and the lowest response was observed at 90 and 270 degrees. Signal was stable during the study period. The detector showed high dose linearity and insignificant fading. But due to angular and depth dependence, care should be taken and corrections must be applied for clinical dosimetry. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  9. An intrauterine ultrasound applicator for targeted delivery of thermal therapy in conjunction with HDR brachytherapy to the cervix

    Science.gov (United States)

    Wootton, Jeffery H.; Juang, Titania; Pouliot, Jean; Hsu, I.-Chow Joe; Diederich, Chris J.

    2009-02-01

    An intracavitary hyperthermia applicator for targeted heat delivery to the cervix was developed based on a linear array of sectored tubular ultrasound transducers that provides truly 3-D heating control (angular and along the length). A central conduit can incorporate an HDR source for sequential or simultaneous delivery of heat and radiation. Hyperthermia treatment volumes were determined from brachytherapy treatment planning data and used as a basis for biothermal simulations analyzing the effects of device parameters, tissue properties, and catheter materials on heating patterns. Devices were then developed with 1-3 elements at 6.5-8 MHz with 90-180° sectors and a 15-35 mm heating length, housed within a 6-mm diameter water-cooled PET catheter. Directional heating from sectored transducers could extend lateral penetration of therapeutic heating (41°C) >2 cm while maintaining rectum and bladder temperatures within 12 mm below thermal damage thresholds. Imaging artifacts were evaluated with standard CT, cone beam CT, and MR images. MR thermal imaging was used to demonstrate shaping of heating profiles in axial and coronal slices with artifact <2 mm from the device. The impact of the high-Z applicator materials on the HDR dose distribution was assessed using a well-type ionization chamber and was found to be less than 6% attenuation, which can readily be accounted for with treatment planning software. The intrauterine ultrasound device has demonstrated potential for 3-D conformal heating of clinical tumors in the delivery of targeted hyperthermia in conjunction with brachytherapy to the cervix.

  10. NETWORK DESIGN IN CLOSE-RANGE PHOTOGRAMMETRY WITH SHORT BASELINE IMAGES

    Directory of Open Access Journals (Sweden)

    L. Barazzetti

    2017-08-01

    Full Text Available The avaibility of automated software for image-based 3D modelling has changed the way people acquire images for photogrammetric applications. Short baseline images are required to match image points with SIFT-like algorithms, obtaining more images than those necessary for “old fashioned” photogrammetric projects based on manual measurements. This paper describes some considerations on network design for short baseline image sequences, especially on precision and reliability of bundle adjustment. Simulated results reveal that the large number of 3D points used for image orientation has very limited impact on network precision.

  11. Network Design in Close-Range Photogrammetry with Short Baseline Images

    Science.gov (United States)

    Barazzetti, L.

    2017-08-01

    The avaibility of automated software for image-based 3D modelling has changed the way people acquire images for photogrammetric applications. Short baseline images are required to match image points with SIFT-like algorithms, obtaining more images than those necessary for "old fashioned" photogrammetric projects based on manual measurements. This paper describes some considerations on network design for short baseline image sequences, especially on precision and reliability of bundle adjustment. Simulated results reveal that the large number of 3D points used for image orientation has very limited impact on network precision.

  12. On metrics for objective and subjective evaluation of high dynamic range video

    Science.gov (United States)

    Minoo, Koohyar; Gu, Zhouye; Baylon, David; Luthra, Ajay

    2015-09-01

    In high dynamic range (HDR) video, it is possible to represent a wider range of intensities and contrasts compared to the current standard dynamic range (SDR) video. HDR video can simultaneously preserve details in very bright and very dark areas of a scene whereas these details become lost or washed out in SDR video. Because the perceived quality due to this increased fidelity may not fit the same model of perceived quality in the SDR video, it is not clear whether the objective metrics that have been widely used and studied for SDR visual experience are reasonably accurate for HDR cases, in terms of correlation with subjective measurement for HDR video quality. This paper investigates several objective metrics and their correlation to subjective quality for a variety of HDR video content. Results are given for the case of HDR content compressed at different bit rates. In addition to rating the relevance of each objective metric in terms of its correlation to the subjective measurements, comparisons are also presented to show how closely different objective metrics can predict the results obtained by subjective quality assessment in terms of coding efficiency provided by different coding processes.

  13. Cloud cover detection combining high dynamic range sky images and ceilometer measurements

    Science.gov (United States)

    Román, R.; Cazorla, A.; Toledano, C.; Olmo, F. J.; Cachorro, V. E.; de Frutos, A.; Alados-Arboledas, L.

    2017-11-01

    This paper presents a new algorithm for cloud detection based on high dynamic range images from a sky camera and ceilometer measurements. The algorithm is also able to detect the obstruction of the sun. This algorithm, called CPC (Camera Plus Ceilometer), is based on the assumption that under cloud-free conditions the sky field must show symmetry. The symmetry criteria are applied depending on ceilometer measurements of the cloud base height. CPC algorithm is applied in two Spanish locations (Granada and Valladolid). The performance of CPC retrieving the sun conditions (obstructed or unobstructed) is analyzed in detail using as reference pyranometer measurements at Granada. CPC retrievals are in agreement with those derived from the reference pyranometer in 85% of the cases (it seems that this agreement does not depend on aerosol size or optical depth). The agreement percentage goes down to only 48% when another algorithm, based on Red-Blue Ratio (RBR), is applied to the sky camera images. The retrieved cloud cover at Granada and Valladolid is compared with that registered by trained meteorological observers. CPC cloud cover is in agreement with the reference showing a slight overestimation and a mean absolute error around 1 okta. A major advantage of the CPC algorithm with respect to the RBR method is that the determined cloud cover is independent of aerosol properties. The RBR algorithm overestimates cloud cover for coarse aerosols and high loads. Cloud cover obtained only from ceilometer shows similar results than CPC algorithm; but the horizontal distribution cannot be obtained. In addition, it has been observed that under quick and strong changes on cloud cover ceilometers retrieve a cloud cover fitting worse with the real cloud cover.

  14. Registration of partially overlapping surfaces for range image based augmented reality on mobile devices

    Science.gov (United States)

    Kilgus, T.; Franz, A. M.; Seitel, A.; Marz, K.; Bartha, L.; Fangerau, M.; Mersmann, S.; Groch, A.; Meinzer, H.-P.; Maier-Hein, L.

    2012-02-01

    Visualization of anatomical data for disease diagnosis, surgical planning, or orientation during interventional therapy is an integral part of modern health care. However, as anatomical information is typically shown on monitors provided by a radiological work station, the physician has to mentally transfer internal structures shown on the screen to the patient. To address this issue, we recently presented a new approach to on-patient visualization of 3D medical images, which combines the concept of augmented reality (AR) with an intuitive interaction scheme. Our method requires mounting a range imaging device, such as a Time-of-Flight (ToF) camera, to a portable display (e.g. a tablet PC). During the visualization process, the pose of the camera and thus the viewing direction of the user is continuously determined with a surface matching algorithm. By moving the device along the body of the patient, the physician is given the impression of looking directly into the human body. In this paper, we present and evaluate a new method for camera pose estimation based on an anisotropic trimmed variant of the well-known iterative closest point (ICP) algorithm. According to in-silico and in-vivo experiments performed with computed tomography (CT) and ToF data of human faces, knees and abdomens, our new method is better suited for surface registration with ToF data than the established trimmed variant of the ICP, reducing the target registration error (TRE) by more than 60%. The TRE obtained (approx. 4-5 mm) is promising for AR visualization, but clinical applications require maximization of robustness and run-time.

  15. The curvHDR method for gating flow cytometry samples

    Directory of Open Access Journals (Sweden)

    Wand Matthew P

    2010-01-01

    Full Text Available Abstract Background High-throughput flow cytometry experiments produce hundreds of large multivariate samples of cellular characteristics. These samples require specialized processing to obtain clinically meaningful measurements. A major component of this processing is a form of cell subsetting known as gating. Manual gating is time-consuming and subjective. Good automatic and semi-automatic gating algorithms are very beneficial to high-throughput flow cytometry. Results We develop a statistical procedure, named curvHDR, for automatic and semi-automatic gating. The method combines the notions of significant high negative curvature regions and highest density regions and has the ability to adapt well to human-perceived gates. The underlying principles apply to dimension of arbitrary size, although we focus on dimensions up to three. Accompanying software, compatible with contemporary flow cytometry infor-matics, is developed. Conclusion The method is seen to adapt well to nuances in the data and, to a reasonable extent, match human perception of useful gates. It offers big savings in human labour when processing high-throughput flow cytometry data whilst retaining a good degree of efficacy.

  16. Robust tracking of respiratory rate in high-dynamic range scenes using mobile thermal imaging

    Science.gov (United States)

    Cho, Youngjun; Julier, Simon J.; Marquardt, Nicolai; Bianchi-Berthouze, Nadia

    2017-01-01

    The ability to monitor the respiratory rate, one of the vital signs, is extremely important for the medical treatment, healthcare and fitness sectors. In many situations, mobile methods, which allow users to undertake everyday activities, are required. However, current monitoring systems can be obtrusive, requiring users to wear respiration belts or nasal probes. Alternatively, contactless digital image sensor based remote-photoplethysmography (PPG) can be used. However, remote PPG requires an ambient source of light, and does not work properly in dark places or under varying lighting conditions. Recent advances in thermographic systems have shrunk their size, weight and cost, to the point where it is possible to create smart-phone based respiration rate monitoring devices that are not affected by lighting conditions. However, mobile thermal imaging is challenged in scenes with high thermal dynamic ranges (e.g. due to the different environmental temperature distributions indoors and outdoors). This challenge is further amplified by general problems such as motion artifacts and low spatial resolution, leading to unreliable breathing signals. In this paper, we propose a novel and robust approach for respiration tracking which compensates for the negative effects of variations in the ambient temperature and motion artifacts and can accurately extract breathing rates in highly dynamic thermal scenes. The approach is based on tracking the nostril of the user and using local temperature variations to infer inhalation and exhalation cycles. It has three main contributions. The first is a novel Optimal Quantization technique which adaptively constructs a color mapping of absolute temperature to improve segmentation, classification and tracking. The second is the Thermal Gradient Flow method that computes thermal gradient magnitude maps to enhance the accuracy of the nostril region tracking. Finally, we introduce the Thermal Voxel method to increase the reliability of the

  17. Robust tracking of respiratory rate in high-dynamic range scenes using mobile thermal imaging.

    Science.gov (United States)

    Cho, Youngjun; Julier, Simon J; Marquardt, Nicolai; Bianchi-Berthouze, Nadia

    2017-10-01

    The ability to monitor the respiratory rate, one of the vital signs, is extremely important for the medical treatment, healthcare and fitness sectors. In many situations, mobile methods, which allow users to undertake everyday activities, are required. However, current monitoring systems can be obtrusive, requiring users to wear respiration belts or nasal probes. Alternatively, contactless digital image sensor based remote-photoplethysmography (PPG) can be used. However, remote PPG requires an ambient source of light, and does not work properly in dark places or under varying lighting conditions. Recent advances in thermographic systems have shrunk their size, weight and cost, to the point where it is possible to create smart-phone based respiration rate monitoring devices that are not affected by lighting conditions. However, mobile thermal imaging is challenged in scenes with high thermal dynamic ranges (e.g. due to the different environmental temperature distributions indoors and outdoors). This challenge is further amplified by general problems such as motion artifacts and low spatial resolution, leading to unreliable breathing signals. In this paper, we propose a novel and robust approach for respiration tracking which compensates for the negative effects of variations in the ambient temperature and motion artifacts and can accurately extract breathing rates in highly dynamic thermal scenes. The approach is based on tracking the nostril of the user and using local temperature variations to infer inhalation and exhalation cycles. It has three main contributions. The first is a novel Optimal Quantization technique which adaptively constructs a color mapping of absolute temperature to improve segmentation, classification and tracking. The second is the Thermal Gradient Flow method that computes thermal gradient magnitude maps to enhance the accuracy of the nostril region tracking. Finally, we introduce the Thermal Voxel method to increase the reliability of the

  18. Endocervical ultrasound applicator for integrated hyperthermia and HDR brachytherapy in the treatment of locally advanced cervical carcinoma

    Science.gov (United States)

    Wootton, Jeffery H.; Hsu, I-Chow Joe; Diederich, Chris J.

    2011-01-01

    Purpose: The clinical success of hyperthermia adjunct to radiotherapy depends on adequate temperature elevation in the tumor with minimal temperature rise in organs at risk. Existing technologies for thermal treatment of the cervix have limited spatial control or rapid energy falloff. The objective of this work is to develop an endocervical applicator using a linear array of multisectored tubular ultrasound transducers to provide 3-D conformal, locally targeted hyperthermia concomitant to radiotherapy in the uterine cervix. The catheter-based device is integrated within a HDR brachytherapy applicator to facilitate sequential and potentially simultaneous heat and radiation delivery. Methods: Treatment planning images from 35 patients who underwent HDR brachytherapy for locally advanced cervical cancer were inspected to assess the dimensions of radiation clinical target volumes (CTVs) and gross tumor volumes (GTVs) surrounding the cervix and the proximity of organs at risk. Biothermal simulation was used to identify applicator and catheter material parameters to adequately heat the cervix with minimal thermal dose accumulation in nontargeted structures. A family of ultrasound applicators was fabricated with two to three tubular transducers operating at 6.6–7.4 MHz that are unsectored (360°), bisectored (2×180°), or trisectored (3×120°) for control of energy deposition in angle and along the device length in order to satisfy anatomical constraints. The device is housed in a 6 mm diameter PET catheter with cooling water flow for endocervical implantation. Devices were characterized by measuring acoustic efficiencies, rotational acoustic intensity distributions, and rotational temperature distributions in phantom. Results: The CTV in HDR brachytherapy plans extends 20.5±5.0 mm from the endocervical tandem with the rectum and bladder typically 5EM43 °C over 4–5 cm diameter with Tmaxconformal thermal delivery to the uterine cervix. Feasibility of heating

  19. Multiple Constraints Based Robust Matching of Poor-Texture Close-Range Images for Monitoring a Simulated Landslide

    Directory of Open Access Journals (Sweden)

    Gang Qiao

    2016-05-01

    Full Text Available Landslides are one of the most destructive geo-hazards that can bring about great threats to both human lives and infrastructures. Landslide monitoring has been always a research hotspot. In particular, landslide simulation experimentation is an effective tool in landslide research to obtain critical parameters that help understand the mechanism and evaluate the triggering and controlling factors of slope failure. Compared with other traditional geotechnical monitoring approaches, the close-range photogrammetry technique shows potential in tracking and recording the 3D surface deformation and failure processes. In such cases, image matching usually plays a critical role in stereo image processing for the 3D geometric reconstruction. However, the complex imaging conditions such as rainfall, mass movement, illumination, and ponding will reduce the texture quality of the stereo images, bringing about difficulties in the image matching process and resulting in very sparse matches. To address this problem, this paper presents a multiple-constraints based robust image matching approach for poor-texture close-range images particularly useful in monitoring a simulated landslide. The Scale Invariant Feature Transform (SIFT algorithm was first applied to the stereo images for generation of scale-invariate feature points, followed by a two-step matching process: feature-based image matching and area-based image matching. In the first feature-based matching step, the triangulation process was performed based on the SIFT matches filtered by the Fundamental Matrix (FM and a robust checking procedure, to serve as the basic constraints for feature-based iterated matching of all the non-matched SIFT-derived feature points inside each triangle. In the following area-based image-matching step, the corresponding points of the non-matched features in each triangle of the master image were predicted in the homologous triangle of the searching image by using geometric

  20. Radiobiological restrictions and tolerance doses of repeated single-fraction hdr-irradiation of intersecting small liver volumes for recurrent hepatic metastases

    Directory of Open Access Journals (Sweden)

    Wust Peter

    2010-05-01

    Full Text Available Abstract Background To assess radiobiological restrictions and tolerance doses as well as other toxic effects derived from repeated applications of single-fraction high dose rate irradiation of small liver volumes in clinical practice. Methods Twenty patients with liver metastases were treated repeatedly (2 - 4 times at identical or intersecting locations by CT-guided interstitial brachytherapy with varying time intervals. Magnetic resonance imaging using the hepatocyte selective contrast media Gd-BOPTA was performed before and after treatment to determine the volume of hepatocyte function loss (called pseudolesion, and the last acquired MRI data set was merged with the dose distributions of all administered brachytherapies. We calculated the BED (biologically equivalent dose for a single dose d = 2 Gy for different α/β values (2, 3, 10, 20, 100 based on the linear-quadratic model and estimated the tolerance dose for liver parenchyma D90 as the BED exposing 90% of the pseudolesion in MRI. Results The tolerance doses D90 after repeated brachytherapy sessions were found between 22 - 24 Gy and proved only slightly dependent on α/β in the clinically relevant range of α/β = 2 - 10 Gy. Variance analysis showed a significant dependency of D90 with respect to the intervals between the first irradiation and the MRI control (p 90 and the pseudolesion's volume. No symptoms of liver dysfunction or other toxic effects such as abscess formation occurred during the follow-up time, neither acute nor on the long-term. Conclusions Inactivation of liver parenchyma occurs at a BED of approx. 22 - 24 Gy corresponding to a single dose of ~10 Gy (α/β ~ 5 Gy. This tolerance dose is consistent with the large potential to treat oligotopic and/or recurrent liver metastases by CT-guided HDR brachytherapy without radiation-induced liver disease (RILD. Repeated small volume irradiation may be applied safely within the limits of this study.

  1. SU-G-201-07: Dosimetric Verification of a 3D Printed HDR Skin Brachytherapy Applicator

    Energy Technology Data Exchange (ETDEWEB)

    Rasmussen, K; Stanley, D; Eng, T; Kirby, N; Gutierrez, A; Stathakis, S; Papanikolaou, N [University of Texas HSC SA, San Antonio, TX (United States); Baumgarten, A; Pelletier, C; Jung, J; Feng, Y; Huang, Z; Ju, A [East Carolina University, Greenville, NC (United States); Corbett, M [Greenville Health System, Greenville, SC (United States)

    2016-06-15

    Purpose: The use of radiation as a treatment modality for skin cancer has increased significantly over the last decade with standardized applicators. Utilizing 3D printing, the ability to make applicators specifically designed for each patient’s anatomy has become economically feasible. With this in mind it was the aim of this study to determine the dosimetric accuracy of a 3-D printed HDR brachytherapy applicator for the skin. Methods: A CT reference image was used to generate a custom applicator based on an anthropomorphic head and neck phantom. To create the applicator a 1cm expansion anteriorly with 0.5cmX0.5cm trenches on the outer surface that were spaced 1cm sup-inf to accommodate standard 6F flexible catheters. The applicator was printed using PLA material using a printrbot simple printer. A treatment plan optimized to deliver a clinically representative volume was created in Oncentra and delivered with a nucletron afterloader. Measurements were made using TLDs and EBT3 gafchromic film that were placed between the applicator and the phantom’s forehead. An additional piece of film was also used to qualitatively asses the dose distribution in the transverse plane. Using a standard vaginal cylinder and bolus, a standardized curve correlating TLD and film exposure-to-radiation dose was established by irradiating film to known doses (200,500,700 cGy) at a 3.5 cm radius distance. Results: Evaluated TLDs showed the absolute dose delivered to the skin surface using the 3-D printed bolus was 615cGy±6%, with a mean predicted TPS value in the measured area of 617.5±7%. Additionally, planar dose distributions had good qualitative agreement with calculated TPS isodoses. Conclusion: This work demonstrates patient specific 3-D printed HDR brachytherapy applicators for skin cancer treatments are practical and accurate in TPS calculations but additional measurements are needed to verify additional sites and dose at depth.

  2. Prediction of object detection, recognition, and identification [DRI] ranges at color scene images based on quantifying human color contrast perception

    Science.gov (United States)

    Pinsky, Ephi; Levin, Ilia; Yaron, Ofer

    2016-10-01

    We propose a novel approach to predict, for specified color imaging system and for objects with known characteristics, their detection, recognition, identification (DRI) ranges in a colored dynamic scene, based on quantifying the human color contrast perception. The method refers to the well established L*a*b*, 3D color space. The nonlinear relations of this space are intended to mimic the nonlinear response of the human eye. The metrics of L*a*b* color space is such that the Euclidian distance between any two colors in this space is approximately proportional to the color contrast as perceived by the human eye/brain. The result of this metrics leads to the outcome that color contrast of any two points is always greater (or equal) than their equivalent grey scale contrast. This meets our sense that looking on a colored image, contrast is superior to the gray scale contrast of the same image. Yet, color loss by scattering at very long ranges should be considered as well. The color contrast derived from the distance between the colored object pixels and to the nearby colored background pixels, as derived from the L*a*b* color space metrics, is expressed in terms of gray scale contrast. This contrast replaces the original standard gray scale contrast component of that image. As expected, the resulted DRI ranges are, in most cases, larger than those predicted by the standard gray scale image. Upon further elaboration and validation of this method, it may be combined with the next versions of the well accepted TRM codes for DRI predictions. Consistent prediction of DRI ranges implies a careful evaluation of the object and background color contrast reduction along the range. Clearly, additional processing for reconstructing the objects and background true colors and hence the color contrast along the range, will further increase the DRI ranges.

  3. Compression of Infrared images

    DEFF Research Database (Denmark)

    Mantel, Claire; Forchhammer, Søren

    2017-01-01

    This paper investigates the compression of infrared images with three codecs: JPEG2000, JPEG-XT and HEVC. Results are evaluated in terms of SNR, Mean Relative Squared Error (MRSE) and the HDR-VDP2 quality metric. JPEG2000 and HEVC perform fairy similar and better than JPEG-XT. JPEG2000 performs...

  4. Trans-Pacific HDR Satellite Communications Experiment Phase-2 Project Plan and Experimental Network

    Science.gov (United States)

    Hsu, Eddie; Kadowaki, Naoto; Yoshimura, Naoko; Takahashi, Takashi; Yoshikawa, Makoto; Bergman, Larry; Bhasin, Kul

    2000-01-01

    The trans-Pacific high data rate (TP-HDR) satellite communications experiment was proposed at the Japan-U.S. Cooperation in Space (JUCS) Program Workshop held in Hawaii in 1993 and remote high definition video post-production was demonstrated as the first phase trial. ATM-based 45 Mbps trans-Pacific link was established in the first phase, and the following experiments with 155 Mbps was planned as the phase 2. This paper describes the experimental network configuration and project plan of TP-HDR experiment phase 2. Additional information is provided in the original.

  5. SIM Grid Star Observations: Astrometry With a New High Dynamic Range Imaging Device

    National Research Council Canada - National Science Library

    Winter, L

    2000-01-01

    ... (developed by the Institut fur Mikroelek-tronik Stuttgart, IMS, Germany) are presented. To test the HDRC4 imager at the telescope, a cooled camera had to be constructed by modifying a camera designed by IMS...

  6. SU-E-T-362: Automatic Catheter Reconstruction of Flap Applicators in HDR Surface Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Buzurovic, I; Devlin, P; Hansen, J; O' Farrell, D; Bhagwat, M; Friesen, S; Damato, A; Lewis, J; Cormack, R [Dana-Farber/Brigham and Women' s Cancer Center, Harvard Medical School, Boston, MA (United States)

    2014-06-01

    Purpose: Catheter reconstruction is crucial for the accurate delivery of radiation dose in HDR brachytherapy. The process becomes complicated and time-consuming for large superficial clinical targets with a complex topology. A novel method for the automatic catheter reconstruction of flap applicators is proposed in this study. Methods: We have developed a program package capable of image manipulation, using C++class libraries of The-Visualization-Toolkit(VTK) software system. The workflow for automatic catheter reconstruction is: a)an anchor point is placed in 3D or in the axial view of the first slice at the tip of the first, last and middle points for the curved surface; b)similar points are placed on the last slice of the image set; c)the surface detection algorithm automatically registers the points to the images and applies the surface reconstruction filter; d)then a structured grid surface is generated through the center of the treatment catheters placed at a distance of 5mm from the patient's skin. As a result, a mesh-style plane is generated with the reconstructed catheters placed 10mm apart. To demonstrate automatic catheter reconstruction, we used CT images of patients diagnosed with cutaneous T-cell-lymphoma and imaged with Freiburg-Flap-Applicators (Nucletron™-Elekta, Netherlands). The coordinates for each catheter were generated and compared to the control points selected during the manual reconstruction for 16catheters and 368control point Results: The variation of the catheter tip positions between the automatically and manually reconstructed catheters was 0.17mm(SD=0.23mm). The position difference between the manually selected catheter control points and the corresponding points obtained automatically was 0.17mm in the x-direction (SD=0.23mm), 0.13mm in the y-direction (SD=0.22mm), and 0.14mm in the z-direction (SD=0.24mm). Conclusion: This study shows the feasibility of the automatic catheter reconstruction of flap applicators with a high

  7. Waveguide piezoelectric micromachined ultrasonic transducer array for short-range pulse-echo imaging

    Science.gov (United States)

    Lu, Y.; Tang, H.; Wang, Q.; Fung, S.; Tsai, J. M.; Daneman, M.; Boser, B. E.; Horsley, D. A.

    2015-05-01

    This paper presents an 8 × 24 element, 100 μm-pitch, 20 MHz ultrasound imager based on a piezoelectric micromachined ultrasonic transducer (PMUT) array having integrated acoustic waveguides. The 70 μm diameter, 220 μm long waveguides function both to direct acoustic waves and to confine acoustic energy, and also to provide mechanical protection for the PMUT array used for surface-imaging applications such as an ultrasonic fingerprint sensor. The imager consists of a PMUT array bonded with a CMOS ASIC using wafer-level conductive eutectic bonding. This construction allows each PMUT in the array to have a dedicated front-end receive amplifier, which together with on-chip analog multiplexing enables individual pixel read-out with high signal-to-noise ratio through minimized parasitic capacitance between the PMUT and the front-end amplifier. Finite element method simulations demonstrate that the waveguides preserve the pressure amplitude of acoustic pulses over distances of 600 μm. Moreover, the waveguide design demonstrated here enables pixel-by-pixel readout of the ultrasound image due to improved directivity of the PMUT by directing acoustic waves and creating a pressure field with greater spatial uniformity at the end of the waveguide. Pulse-echo imaging experiments conducted using a one-dimensional steel grating demonstrate the array's ability to form a two-dimensional image of a target.

  8. Octave-spanning hyperspectral coherent diffractive imaging in the extreme ultraviolet range.

    Science.gov (United States)

    Meng, Yijian; Zhang, Chunmei; Marceau, Claude; Naumov, A Yu; Corkum, P B; Villeneuve, D M

    2015-11-02

    Soft x-ray microscopy is a powerful imaging technique that provides sub-micron spatial resolution, as well as chemical specificity using core-level near-edge x-ray absorption fine structure (NEXAFS). Near the carbon K-edge (280-300 eV) biological samples exhibit high contrast, and the detailed spectrum contains information about the local chemical environment of the atoms. Most soft x-ray imaging takes place on dedicated beamlines at synchrotron facilities or at x-ray free electron laser facilities. Tabletop femtosecond laser systems are now able to produce coherent radiation at the carbon K-edge and beyond through the process of high harmonic generation (HHG). The broad bandwidth of HHG is seemingly a limitation to imaging, since x-ray optical elements such as Fresnel zone plates require monochromatic sources. Counter-intuitively, the broad bandwidth of HHG sources can be beneficial as it permits chemically-specific hyperspectral imaging. We apply two separate techniques - Fourier transform spectroscopy, and lensless holographic imaging - to obtain images of an object simultaneously at multiple wavelengths using an octave-spanning high harmonic source with photon energies up to 30 eV. We use an interferometric delay reference to correct for nanometer-scale fluctuations between the two HHG sources.

  9. Test of the Practicality and Feasibility of EDoF-Empowered Image Sensors for Long-Range Biometrics

    Directory of Open Access Journals (Sweden)

    Sheng-Hsun Hsieh

    2016-11-01

    Full Text Available For many practical applications of image sensors, how to extend the depth-of-field (DoF is an important research topic; if successfully implemented, it could be beneficial in various applications, from photography to biometrics. In this work, we want to examine the feasibility and practicability of a well-known “extended DoF” (EDoF technique, or “wavefront coding,” by building real-time long-range iris recognition and performing large-scale iris recognition. The key to the success of long-range iris recognition includes long DoF and image quality invariance toward various object distance, which is strict and harsh enough to test the practicality and feasibility of EDoF-empowered image sensors. Besides image sensor modification, we also explored the possibility of varying enrollment/testing pairs. With 512 iris images from 32 Asian people as the database, 400-mm focal length and F/6.3 optics over 3 m working distance, our results prove that a sophisticated coding design scheme plus homogeneous enrollment/testing setups can effectively overcome the blurring caused by phase modulation and omit Wiener-based restoration. In our experiments, which are based on 3328 iris images in total, the EDoF factor can achieve a result 3.71 times better than the original system without a loss of recognition accuracy.

  10. Time-of-flight neutron rejection to improve prompt gamma imaging for proton range verification : a simulation study

    NARCIS (Netherlands)

    Biegun, Aleksandra K.; Seravalli, Enrica; Lopes, Patricia Cambraia; Rinaldi, Ilaria; Pinto, Marco; Oxley, David C.; Dendooven, Peter; Verhaegen, Frank; Parodi, Katia; Crespo, Paulo; Schaart, Dennis R.

    2012-01-01

    Therapeutic proton and heavier ion beams generate prompt gamma photons that may escape from the patient. In principle, this allows for real-time, in situ monitoring of the treatment delivery, in particular, the hadron range within the patient, by imaging the emitted prompt gamma rays. Unfortunately,

  11. 3D range-gated super-resolution imaging based on stereo matching for moving platforms and targets

    Science.gov (United States)

    Sun, Liang; Wang, Xinwei; Zhou, Yan

    2017-11-01

    3D range-gated superresolution imaging is a novel 3D reconstruction technique for target detection and recognition with good real-time performance. However, for moving targets or platforms such as airborne, shipborne, remote operated vehicle and autonomous vehicle, 3D reconstruction has a large error or failure. In order to overcome this drawback, we propose a method of stereo matching for 3D range-gated superresolution reconstruction algorithm. In experiment, the target is a doll of Mario with a height of 38cm at the location of 34m, and we obtain two successive frame images of the Mario. To confirm our method is effective, we transform the original images with translation, rotation, scale and perspective, respectively. The experimental result shows that our method has a good result of 3D reconstruction for moving targets or platforms.

  12. The Effect of a Pre-Lens Aperture on the Temperature Range and Image Uniformity of Microbolometer Infrared Cameras

    Energy Technology Data Exchange (ETDEWEB)

    Dinwiddie, Ralph Barton [ORNL; Parris, Larkin S. [Wichita State University; Lindal, John M. [Oak Ridge National Laboratory (ORNL); Kunc, Vlastimil [ORNL

    2016-01-01

    This paper explores the temperature range extension of long-wavelength infrared (LWIR) cameras by placing an aperture in front of the lens. An aperture smaller than the lens will reduce the radiance to the sensor, allowing the camera to image targets much hotter than typically allowable. These higher temperatures were accurately determined after developing a correction factor which was applied to the built-in temperature calibration. The relationship between aperture diameter and temperature range is linear. The effect of pre-lens apertures on the image uniformity is a form of anti-vignetting, meaning the corners appear brighter (hotter) than the rest of the image. An example of using this technique to measure temperatures of high melting point polymers during 3D printing provide valuable information of the time required for the weld-line temperature to fall below the glass transition temperature.

  13. SU-F-T-24: Impact of Source Position and Dose Distribution Due to Curvature of HDR Transfer Tubes

    Energy Technology Data Exchange (ETDEWEB)

    Khan, A; Yue, N [Rutgers University, New Brunswick, NJ (United States)

    2016-06-15

    Purpose: Brachytherapy is a highly targeted from of radiotherapy. While this may lead to ideal dose distributions on the treatment planning system, a small error in source location can lead to change in the dose distribution. The purpose of this study is to quantify the impact on source position error due to curvature of the transfer tubes and the impact this may have on the dose distribution. Methods: Since the source travels along the midline of the tube, an estimate of the positioning error for various angles of curvature was determined using geometric properties of the tube. Based on the range of values a specific shift was chosen to alter the treatment plans for a number of cervical cancer patients who had undergone HDR brachytherapy boost using tandem and ovoids. Impact of dose to target and organs at risk were determined and checked against guidelines outlined by radiation oncologist. Results: The estimate of the positioning error was 2mm short of the expected position (the curved tube can only cause the source to not reach as far as with a flat tube). Quantitative impact on the dose distribution is still in the process of being analyzed. Conclusion: The accepted positioning tolerance for the source position of a HDR brachytherapy unit is plus or minus 1mm. If there is an additional 2mm discrepancy due to tube curvature, this can result in a source being 1mm to 3mm short of the expected location. While we do always attempt to keep the tubes straight, in some cases such as with tandem and ovoids, the tandem connector does not extend as far out from the patient so the ovoid tubes always contain some degree of curvature. The dose impact of this may be significant.

  14. Experimental Study of High-Range-Resolution Medical Acoustic Imaging for Multiple Target Detection by Frequency Domain Interferometry

    Science.gov (United States)

    Kimura, Tomoki; Taki, Hirofumi; Sakamoto, Takuya; Sato, Toru

    2009-07-01

    We employed frequency domain interferometry (FDI) for use as a medical acoustic imager to detect multiple targets with high range resolution. The phase of each frequency component of an echo varies with the frequency, and target intervals can be estimated from the phase variance. This processing technique is generally used in radar imaging. When the interference within a range gate is coherent, the cross correlation between the desired signal and the coherent interference signal is nonzero. The Capon method works under the guiding principle that output power minimization cancels the desired signal with a coherent interference signal. Therefore, we utilize frequency averaging to suppress the correlation of the coherent interference. The results of computational simulations using a pseudoecho signal show that the Capon method with adaptive frequency averaging (AFA) provides a higher range resolution than a conventional method. These techniques were experimentally investigated and we confirmed the effectiveness of the proposed method of processing by FDI.

  15. Discrimination between sedimentary rocks from close-range visible and very-near-infrared images

    NARCIS (Netherlands)

    Pozo, Susana Del; Lindenbergh, R.C.; Rodríguez-Gonzálvez, Pablo; Blom, J.C.; González-Aguilera, Diego

    2015-01-01

    Variation in the mineral composition of rocks results in a change of their spectral response capable of being studied by imaging spectroscopy. This paper proposes the use of a low-cost handy sensor, a calibrated visible-very near infrared (VIS-VNIR) multispectral camera for the recognition of

  16. Prediction of HDR quality by combining perceptually transformed display measurements with machine learning

    Science.gov (United States)

    Choudhury, Anustup; Farrell, Suzanne; Atkins, Robin; Daly, Scott

    2017-09-01

    We present an approach to predict overall HDR display quality as a function of key HDR display parameters. We first performed subjective experiments on a high quality HDR display that explored five key HDR display parameters: maximum luminance, minimum luminance, color gamut, bit-depth and local contrast. Subjects rated overall quality for different combinations of these display parameters. We explored two models | a physical model solely based on physically measured display characteristics and a perceptual model that transforms physical parameters using human vision system models. For the perceptual model, we use a family of metrics based on a recently published color volume model (ICT-CP), which consists of the PQ luminance non-linearity (ST2084) and LMS-based opponent color, as well as an estimate of the display point spread function. To predict overall visual quality, we apply linear regression and machine learning techniques such as Multilayer Perceptron, RBF and SVM networks. We use RMSE and Pearson/Spearman correlation coefficients to quantify performance. We found that the perceptual model is better at predicting subjective quality than the physical model and that SVM is better at prediction than linear regression. The significance and contribution of each display parameter was investigated. In addition, we found that combined parameters such as contrast do not improve prediction. Traditional perceptual models were also evaluated and we found that models based on the PQ non-linearity performed better.

  17. Mixed integer programming improves comprehensibility and plan quality in inverse optimization of prostate HDR Brachytherapy

    NARCIS (Netherlands)

    Gorissen, B.L.; den Hertog, D.; Hoffmann, A.L.

    2013-01-01

    Current inverse treatment planning methods that optimize both catheter positions and dwell times in prostate HDR brachytherapy use surrogate linear or quadratic objective functions that have no direct interpretation in terms of dose-volume histogram (DVH) criteria, do not result in an optimum or

  18. Dwell time modulation restrictions do not necessarily improve treatment plan quality for prostate HDR brachytherapy

    NARCIS (Netherlands)

    Balvert, M.; Gorissen, B.L.; den Hertog, D.; Hoffmann, A.L.

    Inverse planning algorithms for dwell time optimisation in interstitial high-dose-rate (HDR) brachytherapy may produce solutions with large dwell time variations within catheters, which may result in undesirable selective high-dose subvolumes. Extending the dwell time optimisation model with a dwell

  19. An automated optimization tool for high-dose-rate (HDR) prostate brachytherapy with divergent needle pattern

    NARCIS (Netherlands)

    Borot, Maxence; Maenhout, M.; de Senneville, B. Denis; Hautvast, G.; Binnekamp, D.; Lagendijk, J. J. W.; van Vulpen, M.; Moerland, M. A.

    2015-01-01

    Focal high-dose-rate (HDR) for prostate cancer has gained increasing interest as an alternative to whole gland therapy as it may contribute to the reduction of treatment related toxicity. For focal treatment, optimal needle guidance and placement is warranted. This can be achieved under MR guidance.

  20. Processor for Real-Time Atmospheric Compensation in Long-Range Imaging Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Range surveillance is a critical component of space exploration because of its implications on safety, cost, and overall mission timeline. However, launch delays,...

  1. Signal-to-noise ratio improvements in laser flow diagnostics using time-resolved image averaging and high dynamic range imaging

    Science.gov (United States)

    Giassi, Davide; Long, Marshall B.

    2016-08-01

    Two alternative image readout approaches are demonstrated to improve the signal-to-noise ratio (SNR) in temporally resolved laser-based imaging experiments of turbulent phenomena. The first method exploits the temporal decay characteristics of the phosphor screens of image intensifiers when coupled to an interline-transfer CCD camera operated in double-frame mode. Specifically, the light emitted by the phosphor screen, which has a finite decay constant, is equally distributed and recorded over the two sequential frames of the detector so that an averaged image can be reconstructed. The characterization of both detector and image intensifier showed that the technique preserves the correct quantitative information, and its applicability to reactive flows was verified using planar Rayleigh scattering and tested with the acquisition of images of both steady and turbulent partially premixed methane/air flames. The comparison between conventional Rayleigh results and the averaged ones showed that the SNR of the averaged image is higher than the conventional one; with the setup used in this work, the gain in SNR was seen to approach 30 %, for both the steady and turbulent cases. The second technique uses the two-frame readout of an interline-transfer CCD to increase the image SNR based on high dynamic range imaging, and it was tested in an unsteady non-reactive flow of Freon-12 injected in air. The result showed a 15 % increase in the SNR of the low-pixel-count regions of an image, when compared to the pixels of a conventionally averaged one.

  2. Temporo-spatial cell-cycle kinetics in HeLa cells irradiated by Ir-192 high dose-rate remote afterloading system (HDR-RALS).

    Science.gov (United States)

    Asahina, Taito; Kaida, Atsushi; Goto, Tatsuaki; Yoshimura, Ryo-Ichi; Sasai, Keisuke; Miura, Masahiko

    2016-07-29

    Intracavitary irradiation plays a pivotal role in definitive radiotherapy for cervical cancer, and the Ir-192 high dose-rate remote afterloading system (HDR-RALS) is often used for this purpose. Under this condition, tumor tissues receive remarkably different absorption doses, with a steep gradient, depending on distance from the radiation source. To obtain temporo-spatial information regarding cell-cycle kinetics in cervical cancer following irradiation by Ir-192 HDR-RALS, we examined HeLa cells expressing the fluorescence ubiquitination-based cell cycle indicator (Fucci), which allowed us to visualize cell-cycle progression. HeLa-Fucci cells, which emit red and green fluorescence in G1 and S/G2/M phases, respectively, were grown on 35-mm dishes and irradiated by Ir-192 HDR-RALS under normoxic and hypoxic conditions. A 6 French (Fr) catheter was used as an applicator. A radiation dose of 6 Gy was prescribed at hypothetical treatment point A, located 20 mm from the radiation source. Changes in Fucci fluorescence after irradiation were visualized for cells from 5 to 20 mm from the Ir-192 source. Several indices, including first green phase duration after irradiation (FGPD), were measured by analysis of time-lapse images. Cells located 5 to 20 mm from the Ir-192 source became green, reflecting arrest in G2, in a similar manner up to 12 h after irradiation; at more distant positions, however, cells were gradually released from the G2 arrest and became red. This could be explained by the observation that the FGPD was longer for cells closer to the radiation source. Detailed observation revealed that FGPD was significantly longer in cells irradiated in the green phase than in the red phase at positions closer to the Ir-192 source. Unexpectedly, the FGPD was significantly longer after irradiation under hypoxia than normoxia, due in large part to the elongation of FGPD in cells irradiated in the red phase. Using HeLa-Fucci cells, we obtained the first temporo

  3. SU-F-T-37: Dosimetric Evaluation of Planned Versus Decay Corrected Treatment Plans for the Treatment of Tandem-Based Cervical HDR Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Goyal, M [Texas Oncology, PA, Fort Worth, TX (United States); Shobhit University, Meerut, Uttar Pradesh (India); Manjhi, J; Rai, D [Shobhit University, Meerut, Uttar Pradesh (India); Kehwar, T [Pinnacle Health Cancer Center, Mechanicsburg, PA (United States); Barker, J; Heintz, B; Shide, K [Texas Oncology, PA, Fort Worth, TX (United States)

    2016-06-15

    Purpose: This study evaluated dosimetric parameters for actual treatment plans versus decay corrected treatment plans for cervical HDR brachytherapy. Methods: 125 plans of 25 patients, who received 5 fractions of HDR brachytherapy, were evaluated in this study. Dose was prescribed to point A (ICRU-38) and High risk clinical tumor volume (HR-CTV) and organs at risk (OAR) were, retrospectively, delineated on original CT images by treating physician. First HDR plan was considered as reference plan and decay correction was applied to calculate treatment time for subsequent fractions, and was applied, retrospectively, to determine point A, HR-CTV D90, and rectum and bladder doses. Results: The differences between mean point A reference doses and the point A doses of the plans computed using decay times were found to be 1.05%±0.74% (−2.26% to 3.26%) for second fraction; −0.25%±0.84% (−3.03% to 3.29%) for third fraction; 0.04%±0.70% (−2.68% to 2.56%) for fourth fraction and 0.30%±0.81% (−3.93% to 2.67%) for fifth fraction. Overall mean point A dose difference, for all fractions, was 0.29%±0.38% (within ± 5%). Mean rectum and bladder dose differences were calculated to be −3.46%±0.12% and −2.47%±0.09%, for points, respectively, and −1.72%±0.09% and −0.96%±0.06%, for D2cc, respectively. HR-CTV D90 mean dose difference was found to be −1.67% ± 0.11%. There was no statistically significant difference between the reference planned point A doses and that calculated using decay time to the subsequent fractions (p<0.05). Conclusion: This study reveals that a decay corrected treatment will provide comparable dosimetric results and can be utilized for subsequent fractions of cervical HDR brachytherapy instead of actual treatment planning. This approach will increase efficiency, decrease workload, reduce patient observation time between applicator insertion and treatment delivery. This would be particularly useful for institutions with limited

  4. An absorbed dose to water standard for HDR 192Ir brachytherapy sources based on water calorimetry: numerical and experimental proof-of-principle.

    Science.gov (United States)

    Sarfehnia, Arman; Stewart, Kristin; Seuntjens, Jan

    2007-12-01

    Water calorimetry is an established technique for absorbed dose to water measurements in external beams. In this paper, the feasibility of direct absorbed dose measurements for high dose rate (HDR) iridium-192 (192Ir) sources using water calorimetry is established. Feasibility is determined primarily by a balance between the need to obtain sufficient signal to perform a reproducible measurement, the effect of heat loss on the measured signal, and the positioning uncertainty affecting the source-detector distance. The heat conduction pattern generated in water by the Nucletron microSelectron-HDR 192Ir brachytherapy source was simulated using COMSOL MULTIPHYSICS software. Source heating due to radiation self-absorption was calculated using EGSnrcMP. A heat-loss correction k(c) was calculated as the ratio of the temperature rise under ideal conditions to temperature rise under realistic conditions. The calorimeter setup used a parallel-plate calorimeter vessel of 79 mm diameter and 1.12 mm thick front and rear glass windows located 24 mm apart. Absorbed dose was measured with two sources with nominal air kerma strengths of 38 000 and 21 000 U, at source-detector separations ranging from 24.7 to 27.6 mm and irradiation times of 36.0 to 80.0 s. The preliminary measured dose rate per unit air kerma strength of (0.502 +/- 0.007) microGy/(s U) compares well with the TG-43 derived 0.505 microGy/(s U). This work shows that combined dose uncertainties of significantly less than 5% can be achieved with only modest modifications of current water calorimetry techniques and instruments. This work forms the basis of a potential future absolute dose to water standard for HDR 192Ir brachytherapy.

  5. Measuring Pulse Rate Variability using Long-Range, Non-Contact Imaging Photoplethysmography

    Science.gov (United States)

    2016-08-20

    Photoplethysmography (PPG), first pioneered in the 1930’s, is a low cost , noninvasive method of detecting changes in blood volume using variations in...glasses, piercings, and use of skin or beauty products were recorded but not otherwise used for analysis or screening purposes. C. Experimental Design...and Lei Wang. A review of non-contact, low- cost physiological information measurement based on photoplethysmographic imaging. Annu. Int. Conf. IEEE

  6. Effectiveness of two different HDR brachytherapy regimens with the same BED value in cervical cancer

    Directory of Open Access Journals (Sweden)

    Rajesh Vashistha

    2010-07-01

    Full Text Available Purpose: To analyze the effectiveness of biologically effective dose (BED in two different regimens of HDR brachytherapy keeping the same total BED to point A and to compare the relationship of overall treatment time in terms of local control and bladder and rectal complications.Material and methods: The study included two groups comprising a total of 90 cervical cancer patients who underwent external beam radiotherapy (EBRT followed by HDR intracavitary brachytherapy (ICBT. EBRT treatment was delivered by a Co-60 teletherapy unit to a prescribed dose of 45 Gy with 1.8 Gy per fraction in 25 fractions over a period of five weeks. Parallel opposed anterior–posterior (AP/PA fields with no central shielding were used, followed by the HDR ICBT dose, to point A, of either two fractions of 9.5 Gy with a gap of 10 days, or three fractions of 7.5 Gy with a gap of 7 days between the fractions. Gemcitabine (dose of 150 mg/m2 was given weekly to all the patients as a radiosensitizer. The calculate BED3 to point A was almost the same in both groups to keep the same late complication rates. The doses, and BED10 and BED3, were calculated at different bladder and rectal point as well as at the lymphatictrapezoid points. During and after treatment patients were evaluated for local control and complications for 24 months.Results and Conclusions: Doses and BEDs at different bladder, rectal and lymphatic trapezoid points, local control, and complications in both HDR ICBT groups did not have statistically significant differences (p > 0.05. Both HDR ICBT schedules are well tolerable and equally effective.

  7. Image-guided high-dose-rate brachytherapy boost to the dominant intraprostatic lesion using multiparametric magnetic resonance imaging including spectroscopy: Results of a prospective study.

    Science.gov (United States)

    Vigneault, Eric; Mbodji, Khaly; Racine, Louis-Gabriel; Chevrette, Eric; Lavallée, Marie-Claude; Martin, André-Guy; Després, Philippe; Beaulieu, Luc

    To evaluate the long-term outcomes of image-guided high-dose-rate (HDR) brachytherapy boost to the dominant intraprostatic lesion (DIL) using multiparametric magnetic resonance imaging (MRI), including spectroscopy (MRI/magnetic resonance spectroscopy [MRS]). Between December 2009 and March 2011, 20 patients with intermediate-risk prostate cancer underwent multiparametric MRI/MRS protocol before treatment. All patients were treated with an external beam radiotherapy dose of 40 Gy, combined with an HDR brachytherapy boost of 15 Gy. Concurrently, the DIL received a boost of 18 Gy. Missing data during followup were handled with multiple imputations. The median followup was 62 months (range, 23-71 months). Six patients (31%) were classified as favorable intermediate risk and 13 patients (69%) as unfavorable intermediate risk. One patient experienced a prostate-specific antigen biochemical failure, and the 5-year biochemical failure-free survival rate was of 94.7%. The mean International Prostate Symptom Score rose from 7, with respect to baseline, to 10.42 1 month after treatment, and rapidly decreased to 6.97 after 3 months. Grade 1, 2, and 3 acute genitourinary toxicities were reported in 13 (68%), 3 (16%), and 1 (5%) patients, respectively. Grade 1 and 2 late genitourinary toxicities were reported in 9 (53%) and 3 (18%) patients, respectively. Only grade 1 acute and late gastrointestinal toxicities were reported in 4 (21%) and 3 (18%) patients, respectively. Delivering an HDR brachytherapy boost to the DIL using image-guided multiparametric MRI/MRS is feasible with good outcomes for biochemical control, acute and late toxicities, and dosimetric constraints for critical organs. Copyright © 2016 American Brachytherapy Society. All rights reserved.

  8. A contest of sensors in close range 3D imaging: performance evaluation with a new metric test object

    Directory of Open Access Journals (Sweden)

    M. Hess

    2014-06-01

    Full Text Available An independent means of 3D image quality assessment is introduced, addressing non-professional users of sensors and freeware, which is largely characterized as closed-sourced and by the absence of quality metrics for processing steps, such as alignment. A performance evaluation of commercially available, state-of-the-art close range 3D imaging technologies is demonstrated with the help of a newly developed Portable Metric Test Artefact. The use of this test object provides quality control by a quantitative assessment of 3D imaging sensors. It will enable users to give precise specifications which spatial resolution and geometry recording they expect as outcome from their 3D digitizing process. This will lead to the creation of high-quality 3D digital surrogates and 3D digital assets. The paper is presented in the form of a competition of teams, and a possible winner will emerge.

  9. A Fast Component-Tree Algorithm for High Dynamic-Range Images and Second Generation Connectivity

    NARCIS (Netherlands)

    Wilkinson, Michael H. F.

    2011-01-01

    Component trees are important data structures for computation of connected attribute filters. Though some of the available algorithms are suitable for high-dynamic range, and in particular floating point data, none are suitable for computation of component trees for so-called second-generation, and

  10. A Very Low Dark Current Temperature-Resistant, Wide Dynamic Range, Complementary Metal Oxide Semiconductor Image Sensor

    Science.gov (United States)

    Mizobuchi, Koichi; Adachi, Satoru; Tejada, Jose; Oshikubo, Hiromichi; Akahane, Nana; Sugawa, Shigetoshi

    2008-07-01

    A very low dark current (VLDC) temperature-resistant approach which best suits a wide dynamic range (WDR) complementary metal oxide semiconductor (CMOS) image sensor with a lateral over-flow integration capacitor (LOFIC) has been developed. By implementing a low electric field photodiode without a trade-off of full well-capacity, reduced plasma damage, re-crystallization, and termination of silicon-silicon dioxide interface states in the front end of line and back end of line (FEOL and BEOL) in a 0.18 µm, two polycrystalline silicon, three metal (2P3M) process, the dark current is reduced to 11 e-/s/pixel (0.35 e-/s/µm2: pixel area normalized) at 60 °C, which is the lowest value ever reported. For further robustness at low and high temperatures, 1/3-in., 5.6-µm pitch, 800×600 pixel sensor chips with low noise readout circuits designed for a signal and noise hold circuit and a programmable gain amplifier (PGA) have also been deposited with an inorganic cap layer on a micro-lens and covered with a metal hermetically sealed package assembly. Image sensing performance results in 2.4 e-rms temporal noise and 100 dB dynamic range (DR) with 237 ke- full well-capacity. The operating temperature range is extended from -40 to 85 °C while retaining good image quality.

  11. A comparison of optical architectures for constrained long-range imaging

    Science.gov (United States)

    Olson, S. Craig; Goodman, Timothy D.; Sparks, Andrew W.; Wheeler, Craig S.

    2017-05-01

    Long-range airborne full-motion-video systems require large apertures to maximize multiple aspects of system performance, including spatial resolution and sensitivity. As systems push to larger apertures for increased resolution and standoff range, both mounting constraints and atmospheric effects limit their effectiveness. This paper considers two questions: first, under what atmospheric and spectral conditions does it make sense to have a larger aperture; second, what types of optical systems can best exploit movement-constrained mounting? We briefly explore high-level atmospheric considerations in determining sensor aperture size for various spectral bands, following with a comparison of the swept-volume-to-aperture ratio of Ritchey-Chrétien and three-mirror-anastigmat optical systems.

  12. Predicted image quality of a CMOS APS X-ray detector across a range of mammographic beam qualities

    Science.gov (United States)

    Konstantinidis, A.

    2015-09-01

    Digital X-ray detectors based on Complementary Metal-Oxide- Semiconductor (CMOS) Active Pixel Sensor (APS) technology have been introduced in the early 2000s in medical imaging applications. In a previous study the X-ray performance (i.e. presampling Modulation Transfer Function (pMTF), Normalized Noise Power Spectrum (NNPS), Signal-to-Noise Ratio (SNR) and Detective Quantum Efficiency (DQE)) of the Dexela 2923MAM CMOS APS X-ray detector was evaluated within the mammographic energy range using monochromatic synchrotron radiation (i.e. 17-35 keV). In this study image simulation was used to predict how the mammographic beam quality affects image quality. In particular, the experimentally measured monochromatic pMTF, NNPS and SNR parameters were combined with various mammographic spectral shapes (i.e. Molybdenum/Molybdenum (Mo/Mo), Rhodium/Rhodium (Rh/Rh), Tungsten/Aluminium (W/Al) and Tungsten/Rhodium (W/Rh) anode/filtration combinations at 28 kV). The image quality was measured in terms of Contrast-to-Noise Ratio (CNR) using a synthetic breast phantom (4 cm thick with 50% glandularity). The results can be used to optimize the imaging conditions in order to minimize patient's Mean Glandular Dose (MGD).

  13. Design and control of multi-actuated atomic force microscope for large-range and high-speed imaging

    Energy Technology Data Exchange (ETDEWEB)

    Soltani Bozchalooi, I.; Careaga Houck, A. [Department of Mechanical Engineering, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, MA 02139 (United States); AlGhamdi, J. [Department of Mechanical Engineering, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, MA 02139 (United States); Department of Chemistry, College of Science, University of Dammam, Dammam (Saudi Arabia); Youcef-Toumi, K. [Department of Mechanical Engineering, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, MA 02139 (United States)

    2016-01-15

    This paper presents the design and control of a high-speed and large-range atomic force microscopy (AFM). A multi-actuation scheme is proposed where several nano-positioners cooperate to achieve the range and speed requirements. A simple data-based control design methodology is presented to effectively operate the AFM scanner components. The proposed controllers compensate for the coupled dynamics and divide the positioning responsibilities between the scanner components. As a result, the multi-actuated scanner behavior is equivalent to that of a single X–Y–Z positioner with large range and high speed. The scanner of the designed AFM is composed of five nano-positioners, features 6 μm out-of-plane and 120 μm lateral ranges and is capable of high-speed operation. The presented AFM has a modular design with laser spot size of 3.5 μm suitable for small cantilever, an optical view of the sample and probe, a conveniently large waterproof sample stage and a 20 MHz data throughput for high resolution image acquisition at high imaging speeds. This AFM is used to visualize etching of calcite in a solution of sulfuric acid. Layer-by-layer dissolution and pit formation along the crystalline lines in a low pH environment is observed in real time. - Highlights: • High-speed AFM imaging is extended to large lateral and vertical scan ranges. • A general multi-actuation approach to atomic force microscopy is presented. • A high-speed AFM is designed and implemented based on the proposed method. • Multi-actuator control is designed auxiliary to a PID unit to maintain flexibility. • Influence of calcite crystal structure on dissolution is visualized in video form.

  14. Evaluation of the Kerma at the entrance of the labyrin thin in facilities with Co-60 HDR brachytherapy; Evaluacion del Kerma en la entrada del laberinto en instalaciones de braquiterapia de HDR con Co-60

    Energy Technology Data Exchange (ETDEWEB)

    Pujades, M. C.; Granero, D.; Ballester, F.; Perez-Calatayud, J.; Vijande, J.

    2013-07-01

    The purpose of this study is to evaluate the kerma's collision at the entrance of the labyrinth adapting the methodology of the NCRP-151 to a bunker of brachytherapy with Co-60, similar to the one carried out in a previous work with HDR Ir-192. To validate the result is simulated using techniques Monte Carlo (MC) two typical designs of HDR with Co-60 bunker. (Author)

  15. A prospective cohort study to compare treatment results between 2 fractionation schedules of high-dose-rate intracavitary brachytherapy (HDR-ICBT) in patients with cervical cancer.

    Science.gov (United States)

    Huang, Eng-Yen; Sun, Li-Min; Lin, Hao; Lan, Jen-Hong; Chanchien, Chan-Chao; Huang, Yu-Jie; Wang, Chang-Yu; Wang, Chong-Jong

    2013-01-01

    To compare the treatment results of 2 fractionation schedules for high-dose-rate intracavitary brachytherapy (HDR-ICBT) in patients with cervical cancer. From June 2001 through January 2008, 267 patients with stage IB-IVA cervical cancer were enrolled in the study. All patients underwent 4-field pelvic irradiation and HDR-ICBT. The median central and parametrial doses were 39.6 Gy and 45 Gy, respectively. Patient underwent either 6 Gy×4 (HDR-4) (n=144) or 4.5 Gy×6 (HDR-6) (n=123) to point A of ICBT using 192Ir isotope twice weekly. The rates of overall survival, locoregional failure, distant metastasis, proctitis, cystitis, and enterocolitis were compared between HDR-4 and HDR-6. There were no significant differences in the demographic data between HDR-4 and HDR-6 except for total treatment time. The 5-year proctitis rates were 23.0% and 21.5% in HDR-4 and HDR-6 (P=.399), respectively. The corresponding rates of grade 2-4 proctitis were 18.7% and 9.6% (P=.060). The corresponding rates of grades 3-4 proctitis were 5.2% and 1.3% (P=.231). Subgroup analysis revealed that HDR-4 significantly increased grade 2-4 proctitis in patients aged≥62 years old (P=.012) but not in patients agedschedules. The small fraction size of HDR-ICBT is associated with grade 2 proctitis without compromise of prognosis in elderly patients. This schedule is suggested for patients who tolerate an additional 2 applications of HDR-ICBT. Copyright © 2013 Elsevier Inc. All rights reserved.

  16. SU-F-P-42: “To Navigate, Or Not to Navigate: HDR BT in Recurrent Spine Lesions”

    Energy Technology Data Exchange (ETDEWEB)

    Voros, L; Cohen, G; Zaider, M; Yamada, Y [Memorial Sloan-Kettering Cancer Center, New York, NY (United States)

    2016-06-15

    Purpose: We compare the accuracy of HDR catheter placement for paraspinal lesions using O-arm CBCT imaging combined with StealthStation navigation and traditional fluoroscopically guided catheter placement. Methods: CT and MRI scans were acquired pre-treatment to outline the lesions and design treatment plans (pre-plans) to meet dosimetric constrains. The pre-planned catheter trajectories were transferred into the StealthStation Navigation system prior to the surgery. The StealthStation is an infra red (IR) optical navigation system used for guidance of surgical instruments. An intraoperative CBCT scan (O-arm) was acquired with reference IR optical fiducials anchored onto the patient and registered with the preplan image study to guide surgical instruments in relation to the patients’ anatomy and to place the brachytherapy catheters along the pre-planned trajectories. The final treatment plan was generated based on a 2nd intraoperative CBCT scan reflecting achieved implant geometry. The 2nd CBCT was later registered with the initial CT scan to compare the preplanned dwell positions with actual dwell positions (catheter placements). Similar workflow was used in placement of 8 catheters (1 patient) without navigation, but under fluoroscopy guidance in an interventional radiology suite. Results: A total of 18 catheters (3 patients) were placed using navigation assisted surgery. Average displacement of 0.66 cm (STD=0.37cm) was observed between the pre-plan source positions and actual source positions in the 3 dimensional space. This translates into an average 0.38 cm positioning error in one direction including registration errors, digitization errors, and the surgeons ability to follow the planned trajectory. In comparison, average displacement of non-navigated catheters was 0.50 cm (STD=0.22cm). Conclusion: Spinal lesion HDR brachytherapy planning is a difficult task. Catheter placement has a direct impact on target coverage and dose to critical structures. While

  17. Tilt-pair analysis of images from a range of different specimens in single-particle electron cryomicroscopy.

    Science.gov (United States)

    Henderson, Richard; Chen, Shaoxia; Chen, James Z; Grigorieff, Nikolaus; Passmore, Lori A; Ciccarelli, Luciano; Rubinstein, John L; Crowther, R Anthony; Stewart, Phoebe L; Rosenthal, Peter B

    2011-11-11

    The comparison of a pair of electron microscope images recorded at different specimen tilt angles provides a powerful approach for evaluating the quality of images, image-processing procedures, or three-dimensional structures. Here, we analyze tilt-pair images recorded from a range of specimens with different symmetries and molecular masses and show how the analysis can produce valuable information not easily obtained otherwise. We show that the accuracy of orientation determination of individual single particles depends on molecular mass, as expected theoretically since the information in each particle image increases with molecular mass. The angular uncertainty is less than 1° for particles of high molecular mass (~50 MDa), several degrees for particles in the range 1-5 MDa, and tens of degrees for particles below 1 MDa. Orientational uncertainty may be the major contributor to the effective temperature factor (B-factor) describing contrast loss and therefore the maximum resolution of a structure determination. We also made two unexpected observations. Single particles that are known to be flexible showed a wider spread in orientation accuracy, and the orientations of the largest particles examined changed by several degrees during typical low-dose exposures. Smaller particles presumably also reorient during the exposure; hence, specimen movement is a second major factor that limits resolution. Tilt pairs thus enable assessment of orientation accuracy, map quality, specimen motion, and conformational heterogeneity. A convincing tilt-pair parameter plot, where 60% of the particles show a single cluster around the expected tilt axis and tilt angle, provides confidence in a structure determined using electron cryomicroscopy. Copyright © 2011 Elsevier Ltd. All rights reserved.

  18. Range-Gated LADAR Coherent Imaging Using Parametric Up-Conversion of IR and NIR Light for Imaging with a Visible-Range Fast-Shuttered Intensified Digital CCD Camera

    Energy Technology Data Exchange (ETDEWEB)

    YATES,GEORGE J.; MCDONALD,THOMAS E. JR.; BLISS,DAVID E.; CAMERON,STEWART M.; ZUTAVERN,FRED J.

    2000-12-20

    Research is presented on infrared (IR) and near infrared (NIR) sensitive sensor technologies for use in a high speed shuttered/intensified digital video camera system for range-gated imaging at ''eye-safe'' wavelengths in the region of 1.5 microns. The study is based upon nonlinear crystals used for second harmonic generation (SHG) in optical parametric oscillators (OPOS) for conversion of NIR and IR laser light to visible range light for detection with generic S-20 photocathodes. The intensifiers are ''stripline'' geometry 18-mm diameter microchannel plate intensifiers (MCPIIS), designed by Los Alamos National Laboratory and manufactured by Philips Photonics. The MCPIIS are designed for fast optical shattering with exposures in the 100-200 ps range, and are coupled to a fast readout CCD camera. Conversion efficiency and resolution for the wavelength conversion process are reported. Experimental set-ups for the wavelength shifting and the optical configurations for producing and transporting laser reflectance images are discussed.

  19. Applications of the Integrated High-Performance CMOS Image Sensor to Range Finders — from Optical Triangulation to the Automotive Field

    Science.gov (United States)

    Wu, Jih-Huah; Pen, Cheng-Chung; Jiang, Joe-Air

    2008-01-01

    With their significant features, the applications of complementary metal-oxide semiconductor (CMOS) image sensors covers a very extensive range, from industrial automation to traffic applications such as aiming systems, blind guidance, active/passive range finders, etc. In this paper CMOS image sensor-based active and passive range finders are presented. The measurement scheme of the proposed active/passive range finders is based on a simple triangulation method. The designed range finders chiefly consist of a CMOS image sensor and some light sources such as lasers or LEDs. The implementation cost of our range finders is quite low. Image processing software to adjust the exposure time (ET) of the CMOS image sensor to enhance the performance of triangulation-based range finders was also developed. An extensive series of experiments were conducted to evaluate the performance of the designed range finders. From the experimental results, the distance measurement resolutions achieved by the active range finder and the passive range finder can be better than 0.6% and 0.25% within the measurement ranges of 1 to 8 m and 5 to 45 m, respectively. Feasibility tests on applications of the developed CMOS image sensor-based range finders to the automotive field were also conducted. The experimental results demonstrated that our range finders are well-suited for distance measurements in this field. PMID:27879789

  20. Proposed NRC portable target case for short-range triangulation-based 3D imaging systems characterization

    Science.gov (United States)

    Carrier, Benjamin; MacKinnon, David; Cournoyer, Luc; Beraldin, J.-Angelo

    2011-03-01

    The National Research Council of Canada (NRC) is currently evaluating and designing artifacts and methods to completely characterize 3-D imaging systems. We have gathered a set of artifacts to form a low-cost portable case and provide a clearly-defined set of procedures for generating characteristic values using these artifacts. In its current version, this case is specifically designed for the characterization of short-range (standoff distance of 1 centimeter to 3 meters) triangulation-based 3-D imaging systems. The case is known as the "NRC Portable Target Case for Short-Range Triangulation-based 3-D Imaging Systems" (NRC-PTC). The artifacts in the case have been carefully chosen for their geometric, thermal, and optical properties. A set of characterization procedures are provided with these artifacts based on procedures either already in use or are based on knowledge acquired from various tests carried out by the NRC. Geometric dimensioning and tolerancing (GD&T), a well-known terminology in the industrial field, was used to define the set of tests. The following parameters of a system are characterized: dimensional properties, form properties, orientation properties, localization properties, profile properties, repeatability, intermediate precision, and reproducibility. A number of tests were performed in a special dimensional metrology laboratory to validate the capability of the NRC-PTC. The NRC-PTC will soon be subjected to reproducibility testing using an intercomparison evaluation to validate its use in different laboratories.

  1. Genetic characterization of the hdrRM operon: a novel high-cell-density-responsive regulator in Streptococcus mutans.

    Science.gov (United States)

    Merritt, Justin; Zheng, Lanyan; Shi, Wenyuan; Qi, Fengxia

    2007-08-01

    Many species of bacteria can adhere to surfaces and grow as sessile communities. The continued accumulation of bacteria can eventually lead to the extremely high-cell-density environment characteristic of many biofilms or cell colonies. This is the normal habitat of the cariogenic species Streptococcus mutans, which normally resides in the high-cell-density, multispecies community commonly referred to as dental plaque. Previous work has demonstrated that the transcription of two separate bacteriocins can be activated by the high-cell-density conditions created through the centrifugation and incubation of cell pellets. In this study, we identified an uncharacterized two-gene operon that was induced >10-fold by conditions of high cell density. The genes of the operon encode a putative transcription regulator and a membrane protein, which were renamed as hdrR and hdrM, respectively. A transcription fusion to the hdrRM operon confirmed its induction by high cell density. Mutation of hdrM abolished bacteriocin production, greatly increased natural competence, reduced the growth rate, and severely affected biofilm formation. Interestingly, no obvious phenotypes were observed from a non-polar mutation of hdrR or mutations affecting the entire operon. These data suggest that the hdrRM operon may constitute a novel regulatory system responsible for mediating a cellular response to a high-cell-density environment.

  2. Lightness perception in high dynamic range images: local and remote luminance effects.

    Science.gov (United States)

    Allred, Sarah R; Radonjic, Ana; Gilchrist, Alan L; Brainard, David H

    2012-02-08

    We measured the perceived lightness of target patches embedded in high dynamic range checkerboards. We independently varied the luminance of checks immediately surrounding the test and those remote from it. The data establish context transfer functions (CTFs) that characterize perceptual matches across checkerboard contexts. Several features of the CTFs are broadly consistent with previous research: Matched luminance decreases when overall context luminance decreases; matched luminance increases when overall context luminance increases; manipulating context locations near the target has a greater effect than manipulating locations far from the target patch. The measured CTFs are not well described, however, by changes with context in multiplicative gain alone or by changes in both multiplicative and subtractive adaptation parameters. We were able to fit the data with a three-parameter model of adaptation. This allowed us to characterize the CTFs by specifying the luminances that appeared white, black, and gray (white point, black point, and gray point, respectively). The white and black points depended additively on the local and remote contrasts, but accounting for the gray point required an interaction term. Analysis of this effect suggests that the target patch itself must be included in a description of the visual context.

  3. A Dynamic Range Enhanced Readout Technique with a Two-Step TDC for High Speed Linear CMOS Image Sensors

    Directory of Open Access Journals (Sweden)

    Zhiyuan Gao

    2015-11-01

    Full Text Available This paper presents a dynamic range (DR enhanced readout technique with a two-step time-to-digital converter (TDC for high speed linear CMOS image sensors. A multi-capacitor and self-regulated capacitive trans-impedance amplifier (CTIA structure is employed to extend the dynamic range. The gain of the CTIA is auto adjusted by switching different capacitors to the integration node asynchronously according to the output voltage. A column-parallel ADC based on a two-step TDC is utilized to improve the conversion rate. The conversion is divided into coarse phase and fine phase. An error calibration scheme is also proposed to correct quantization errors caused by propagation delay skew within −Tclk~+Tclk. A linear CMOS image sensor pixel array is designed in the 0.13 μm CMOS process to verify this DR-enhanced high speed readout technique. The post simulation results indicate that the dynamic range of readout circuit is 99.02 dB and the ADC achieves 60.22 dB SNDR and 9.71 bit ENOB at a conversion rate of 2 MS/s after calibration, with 14.04 dB and 2.4 bit improvement, compared with SNDR and ENOB of that without calibration.

  4. [Research on the range of motion measurement system for spine based on LabVIEW image processing technology].

    Science.gov (United States)

    Li, Xiaofang; Deng, Linhong; Lu, Hu; He, Bin

    2014-08-01

    A measurement system based on the image processing technology and developed by LabVIEW was designed to quickly obtain the range of motion (ROM) of spine. NI-Vision module was used to pre-process the original images and calculate the angles of marked needles in order to get ROM data. Six human cadaveric thoracic spine segments T7-T10 were selected to carry out 6 kinds of loads, including left/right lateral bending, flexion, extension, cis/counterclockwise torsion. The system was used to measure the ROM of segment T8-T9 under the loads from 1 Nm to 5 Nm. The experimental results showed that the system is able to measure the ROM of the spine accurately and quickly, which provides a simple and reliable tool for spine biomechanics investigators.

  5. Towards a comprehensive eye model for zebrafish retinal imaging using full range spectral domain optical coherence tomography

    Science.gov (United States)

    Gaertner, Maria; Weber, Anke; Cimalla, Peter; Köttig, Felix; Brand, Michael; Koch, Edmund

    2014-03-01

    In regenerative medicine, the zebrafish is a prominent animal model for studying degeneration and regeneration processes, e.g. of photoreceptor cells in the retina. By means of optical coherence tomography (OCT), these studies can be conducted over weeks using the same individual and hence reducing the variability of the results. To allow an improvement of zebrafish retinal OCT imaging by suitable optics, we developed a zebrafish eye model using geometrical data obtained by in vivo dispersion encoded full range OCT as well as a dispersion comprising gradient index (GRIN) lens model based on refractive index data found in the literature. Using non-sequential ray tracing, the focal length of the spherical GRIN lens (diameter of 0.96 mm) was determined to be 1.22 mm at 800 nm wavelength giving a Matheissen's ratio (ratio of focal length to radius of the lens) of 2.54, which fits well into the range between 2.19 and 2.82, found for various fish lenses. Additionally, a mean refractive index of 1.64 at 800 nm could be retrieved for the lens to yield the same focal position as found for the GRIN condition. With the aid of the zebrafish eye model, the optics of the OCT scanner head were adjusted to provide high-resolution retinal images with a field of view of 30° x 30°. The introduced model therefore provides the basis for improved retinal imaging with OCT and can be further used to study the image formation within the zebrafish eye.

  6. SU-C-16A-03: Direction Modulated Brachytherapy for HDR Treatment of Cervical Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Han, D; Webster, M; Scanderbeg, D; Yashar, C; Choi, D; Song, B; Song, W [University of California, San Diego, La Jolla, CA (United States); Devic, S [McGill University, Montreal, QC (Canada); Ravi, A [Sunnybrook Odette Cancer Centre, Toronto (Canada)

    2014-06-15

    Purpose: To investigate a new Directional Modulated Brachytherapy (DMBT) intra-uterine tandem using various 192-Ir after-loaders. Methods: Dose distributions from the 192-Ir sources were modulated using a 6.3mm diameter tungsten shield (18.0g/cm3). The source moved along 6 longitudinal grooves, each 1.3mm in diameter, evenly spaced along periphery of the shield, The tungsten rod was enclosqed by 0.5mm thick Delrin (1.41g/cc). Monte Carlo N particle (MCNPX) was used to calculate dose distributions. 51million particles were calculated on 504 cores of a supercomputer. Fifteen different patients originally treated with a traditional tandem-and-ovoid applicator, with 5 fractions each, (15 patients X 5 fxs = 75 plans) were re-planned with the DMBT applicator combined with traditional ovoids, on an in-house developed HDR brachytherapy planning platform, which used intensity modulated planning capabilities using a constrained gradient optimization algorithm. For all plans the prescription dose was 6 Gy and they were normalized to match the clinical treated V100. Results: Generally, the DMBT plan quality was a remarkable improvement from conventional T and O plans because of the anisotropic dose distribution of DMBT. The largest difference was to the bladder which had a 0.59±0.87 Gy (8.5±28.7%) reduction in dose. This was because of the the horseshoe shape (U-shape) of the bladder. The dose reduction to rectum and sigmoid were 0.48±0.55 Gy (21.1±27.2%) and 0.10±0.38 Gy (40.6±214.9%), respectively. The D90 to the HRCTV was 6.55±0.96 Gy (conventional T and O) and 6.59±1.06 Gy (DMBT). Conclusion: For image guided adaptive brachytherapy, greater flexibility of radiation intensity is essential and DMBT can be the solution.

  7. Faulting mechanisms and stress regime at the European HDR site of Soultz-sous-Forets, France

    Energy Technology Data Exchange (ETDEWEB)

    Cuenot, Nicolas; Charlety, Jean; Haessler, Henri [Institut de Physique du Globe de Strasbourg, Ecole et Observatoire des Sciences de la Terre (IPGS-EOST), 5 rue Rene Descartes, 67084 Strasbourg Cedex (France); Dorbath, Louis [Institut de Physique du Globe de Strasbourg, Ecole et Observatoire des Sciences de la Terre (IPGS-EOST), 5 rue Rene Descartes, 67084 Strasbourg Cedex (France); Institut de Recherche pour le Developpement, Laboratoire des Mecanismes et Transferts en Geologie (IRD, LMTG), 14 Avenue Edouard Belin, 31400 Toulouse (France)

    2006-10-15

    The state of stress and its implications for shear on fault planes during fluid injection are crucial issues for the HDR (Hot Dry Rock) or EGS (Enhanced or Engineered Geothermal System) concept. This is especially true for hydraulic stimulation experiments, aimed at enhancing the connectivity of a borehole to the natural fracture network, since they tend to induce the shearing of fractures, which is controlled by the local stress regime. During the 2000 and 2003 stimulation tests at Soultz-sous-Forets, France, about 10,000 microearthquakes were located with a surface seismological network. Hundreds of double-couple (DC) focal mechanisms were automatically determined from first-motion polarities using the FPFIT program [Reasenberg, P.A., Oppenheimer, D., 1985. FPFIT, FPPLOT and FPPAGE: Fortran computer programs for calculating and displaying earthquake fault-plane solutions. US Geological Survey Open-File Report 85-739, 25 pp.]. The majority of these mechanisms indicate normal-faulting movement with a more or less pronounced strike-slip component. Some quasi-pure strike-slip events also occurred, especially in the deeper part of the stimulated rock volume, at more than 5 km depth. Although we found a double-couple solution for all events, we tried to observe and quantify the proportion of the non-double-couple (NDC) component in the seismic moment tensor for several microseisms from the 2003 data. The study shows that the NDC is higher for the events in the vicinity of the injection well than for the events far from the well. We used the method of Rivera and Cisternas [Rivera, L., Cisternas, A., 1990. Stress tensor and fault-plane solutions for a population of earthquakes. Bull. Seismol. Soc. Am. 80, 600-614.] to perform the inversion of the deviatoric part of the stress tensor from P-wave polarities. This method was applied to different datasets from the 2000 test, taken from the shallower and deeper parts of the stimulated region. The results show a stable

  8. Dosimetric study of surface applicators of HDR brachytherapy GammaMed Plus equipment

    Energy Technology Data Exchange (ETDEWEB)

    Reyes-Rivera, E., E-mail: eric-1985@fisica.ugto.mx, E-mail: modesto@fisica.ugto.mx, E-mail: uvaldoreyes@fisica.ugto.mx; Sosa, M., E-mail: eric-1985@fisica.ugto.mx, E-mail: modesto@fisica.ugto.mx, E-mail: uvaldoreyes@fisica.ugto.mx; Reyes, U., E-mail: eric-1985@fisica.ugto.mx, E-mail: modesto@fisica.ugto.mx, E-mail: uvaldoreyes@fisica.ugto.mx; Jesús Bernal-Alvarado, José de, E-mail: bernal@fisica.ugto.mx, E-mail: theo@fisica.ugto.mx, E-mail: gil@fisica.ugto.mx; Córdova, T., E-mail: bernal@fisica.ugto.mx, E-mail: theo@fisica.ugto.mx, E-mail: gil@fisica.ugto.mx; Gil-Villegas, A., E-mail: bernal@fisica.ugto.mx, E-mail: theo@fisica.ugto.mx, E-mail: gil@fisica.ugto.mx [División de Ciencias e Ingenierías, Universidad de Guanajuato, 37150 León, Gto. (Mexico); Monzón, E., E-mail: emonzon@imss.gob.mx [Unidad de Alta Especialidad No.1, Instituto Mexicano del Seguro Social, Léon, Gto. (Mexico)

    2014-11-07

    The cone type surface applicators used in HDR brachytherapy for treatment of small skin lesions are an alternative to be used with both electron beams and orthovoltage X-ray equipment. For a good treatment planning is necessary to know the dose distribution of these applicators, which can be obtained by experimental measurement and Monte Carlo simulation as well. In this study the dose distribution of surface applicators of 3 and 3.5 cm diameter, respectively of HDR brachytherapy GammaMed Plus equipment has been estimated using the Monte Carlo method, MCNP code. The applicators simulated were placed on the surface of a water phantom of 20 × 20 × 20 cm and the dose was calculated at depths from 0 to 3 cm with increments of 0.25 mm. The dose profiles obtained at depth show the expected gradients for surface therapy.

  9. Dosimetric study of surface applicators of HDR brachytherapy GammaMed Plus equipment

    Science.gov (United States)

    Reyes-Rivera, E.; Sosa, M.; Reyes, U.; Monzón, E.; de Jesús Bernal-Alvarado, José; Córdova, T.; Gil-Villegas, A.

    2014-11-01

    The cone type surface applicators used in HDR brachytherapy for treatment of small skin lesions are an alternative to be used with both electron beams and orthovoltage X-ray equipment. For a good treatment planning is necessary to know the dose distribution of these applicators, which can be obtained by experimental measurement and Monte Carlo simulation as well. In this study the dose distribution of surface applicators of 3 and 3.5 cm diameter, respectively of HDR brachytherapy GammaMed Plus equipment has been estimated using the Monte Carlo method, MCNP code. The applicators simulated were placed on the surface of a water phantom of 20 × 20 × 20 cm and the dose was calculated at depths from 0 to 3 cm with increments of 0.25 mm. The dose profiles obtained at depth show the expected gradients for surface therapy.

  10. Quality control for cervical cancer treatments on Hdr brachytherapy with Ir-192

    Energy Technology Data Exchange (ETDEWEB)

    Alvarino B, G.; Cogollo P, R.; Paez M, M., E-mail: lvarinog@hotmail.com [Universidad de Cordoba, Physics and Electronics Department, Carrera 6 No. 76-103, Monteria, Cordoba (Colombia)

    2013-10-01

    This work, developed at the National Cancer Institute in partnership with Universidad Nacional de Colombia located in Bogota, Colombia, presents the results of simulations of cervical cancer treatments, on Hdr brachytherapy with Ir-192, using as a physical simulator a natural female pelvis bone with soft tissue elaborated with the experimental material JJT. The doses were measured experimentally, prior to dosimetric characterization, with crystal thermoluminescence 100 LiF: Mg, Ti, located in the organs at risk: rectum and bladder. On the other hand, these treatments were planned and calculated theoretically by the system Micro-Selectron Hdr, with Plato brachytherapy software V 14.1 from the Netherlands Nucletron, and doses obtained in the same organs were compared with experimental results using dosimeters. The comparison of these results shows the correlation degree between the planning of dosimetric treatments and the experimental results, making the process in a form of quality control in vivo, of this type of procedure. (Author)

  11. Long-range laser scanning and 3D imaging for the Gneiss quarries survey

    Science.gov (United States)

    Schenker, Filippo Luca; Spataro, Alessio; Pozzoni, Maurizio; Ambrosi, Christian; Cannata, Massimiliano; Günther, Felix; Corboud, Federico

    2016-04-01

    In Canton Ticino (Southern Switzerland), the exploitation of natural stone, mostly gneisses, is an important activity of valley's economies. Nowadays, these economic activities are menaced by (i) the exploitation costs related to geological phenomena such as fractures, faults and heterogeneous rocks that hinder the processing of the stone product, (ii) continuously changing demand because of the evolving natural stone fashion and (iii) increasing administrative limits and rules acting to protect the environment. Therefore, the sustainable development of the sector for the next decades needs new and effective strategies to regulate and plan the quarries. A fundamental step in this process is the building of a 3D geological model of the quarries to constrain the volume of commercial natural stone and the volume of waste. In this context, we conducted Terrestrial Laser Scanning surveys of the quarries in the Maggia Valley to obtain a detailed 3D topography onto which the geological units were mapped. The topographic 3D model was obtained with a long-range laser scanning Riegl VZ4000 that can measure from up to 4 km of distance with a speed of 147,000 points per second. It operates with the new V-line technology, which defines the surface relief by sensing differentiated signals (echoes), even in the presence of obstacles such as vegetation. Depending on the esthetics of the gneisses, we defined seven types of natural stones that, together with faults and joints, were mapped onto the 3D models of the exploitation sites. According to the orientation of the geological limits and structures, we projected the different rock units and fractures into the excavation front. This way, we obtained a 3D geological model from which we can quantitatively estimate the volume of the seven different natural stones (with different commercial value) and waste (with low commercial value). To verify the 3D geological models and to quantify exploited rock and waste volumes the same

  12. Flexible cross-correlated (C2) imaging method for the modal content characterization in a broad range of wavelengths

    DEFF Research Database (Denmark)

    Muliar, Olena; Usuga Castaneda, Mario A.; Michieletto, Mattia

    2017-01-01

    as the phase distribution are extracted by the alternative method of 2D FT filtering. Being exceptionally tunable the flexible C2 method gives an ability to adapt the system’s parameters in a desired manner satisfying even measurements of very specific fiber designs opening up new possibilities for advanced......We demonstrate a flexible cross-correlated (C2) imaging method in the time domain by application of a tunable and highly flexible light source. An advantage of the flexible C2method is shown by characterization of the step-index fiber (SMF28) over a broad range of wavelengths from 870nm to 1090nm...

  13. Advanced single-stream HDR coding using JVET JEM with backward compatibility options

    Science.gov (United States)

    Topiwala, Pankaj; Dai, Wei; Krishnan, Madhu

    2017-09-01

    This paper presents a state of the art approach in HDR/WCG video coding developed at FastVDO called FVHDR, and based on the JEM 6 Test Model of the Joint Exploration Team, a joint committee of ITU|ISO/IEC. A fully automatic adaptive video process that differs from a known HDR video processing chain (analogous to HDR10, herein called "anchor") developed recently in the standards committee JVET, is used. FVHDR works entirely within the framework of JEM software model, but adds additional tools. These tools can become an integral part of a future video coding standard, or be extracted as additional pre- and post-processing chains. Reconstructed video sequences using FVHDR show a subjective visual quality superior to the output of the anchor. Moreover the resultant SDR content generated by the data adaptive grading process is backward compatible. Representative objective results for the system include: results for DE100, and PSNRL100, were -13.4%, and -3.8% respectively.

  14. Class solution in inverse planned HDR prostate brachytherapy for dose escalation of DIL defined by combined MRI/MRSI

    Science.gov (United States)

    Kim, Yongbok; Hsu, I-Chow J.; Lessard, Etienne; Kurhanewicz, John; Noworolski, Susan Moyher; Pouliot, Jean

    2015-01-01

    Purpose To establish an inverse planning set of parameters (class solution) to boost dominant intra-prostatic lesion (DIL) defined by MRI/MRSI. Methods For 15 patients, DIL were contoured on CT or MR images and a class solution was developed to boost the DIL under the dosimetric requirements of the RTOG-0321 protocol. To determine the maximum attainable level of boost for each patient, 5 different levels were considered, at least 110%, 120%, 130%, 140% and 150% of the prescribed dose. The maximum attainable level was compared to the plan without boost using cumulative dose volume histogram (DVH). Results DIL dose escalation was feasible for 11/15 patients under the requirements. The planning target volume (PTV) dose was slightly increased, while the DIL dose was significantly increased without any violation of requirements. With slight adjustments of the dose constraint parameters, the dose escalation was feasible for 13/15 patients under requirements. Conclusion Using a class solution, a dose escalation of the MRI/MRSI defined DIL up to 150% while complying with RTOG dosimetric requirements is feasible. This HDR brachytherapy approach to dose escalation allows a significant dose increase to the tumor while maintaining an acceptable risk of complications. PMID:18083260

  15. A laboratory-based Laue X-ray diffraction system for enhanced imaging range and surface grain mapping.

    Science.gov (United States)

    Whitley, William; Stock, Chris; Huxley, Andrew D

    2015-08-01

    Although CCD X-ray detectors can be faster to use, their large-area versions can be much more expensive than similarly sized photographic plate detectors. When indexing X-ray diffraction patterns, large-area detectors can prove very advantageous as they provide more spots, which makes fitting an orientation easier. On the other hand, when looking for single crystals in a polycrystalline sample, the speed of CCD detectors is more useful. A new setup is described here which overcomes some of the limitations of limited-range CCD detectors to make them more useful for indexing, whilst at the same time making it much quicker to find single crystals within a larger polycrystalline structure. This was done by combining a CCD detector with a six-axis goniometer, allowing the compilation of images from different angles into a wide-angled image. Automated scans along the sample were coupled with image processing techniques to produce grain maps, which can then be used to provide a strategy to extract single crystals from a polycrystal.

  16. Short range shooting distance estimation using variable pressure SEM images of the surroundings of bullet holes in textiles.

    Science.gov (United States)

    Hinrichs, Ruth; Frank, Paulo Ricardo Ost; Vasconcellos, M A Z

    2017-03-01

    Modifications of cotton and polyester textiles due to shots fired at short range were analyzed with a variable pressure scanning electron microscope (VP-SEM). Different mechanisms of fiber rupture as a function of fiber type and shooting distance were detected, namely fusing, melting, scorching, and mechanical breakage. To estimate the firing distance, the approximately exponential decay of GSR coverage as a function of radial distance from the entrance hole was determined from image analysis, instead of relying on chemical analysis with EDX, which is problematic in the VP-SEM. A set of backscattered electron images, with sufficient magnification to discriminate micrometer wide GSR particles, was acquired at different radial distances from the entrance hole. The atomic number contrast between the GSR particles and the organic fibers allowed to find a robust procedure to segment the micrographs into binary images, in which the white pixel count was attributed to GSR coverage. The decrease of the white pixel count followed an exponential decay, and it was found that the reciprocal of the decay constant, obtained from the least-square fitting of the coverage data, showed a linear dependence on the shooting distance. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.

  17. Wide range local resistance imaging on fragile materials by conducting probe atomic force microscopy in intermittent contact mode

    Energy Technology Data Exchange (ETDEWEB)

    Vecchiola, Aymeric [Laboratoire de Génie électrique et électronique de Paris (GeePs), UMR 8507 CNRS-CentraleSupélec, Paris-Sud and UPMC Universities, 11 rue Joliot-Curie, Plateau de Moulon, 91192 Gif-sur-Yvette (France); Concept Scientific Instruments, ZA de Courtaboeuf, 2 rue de la Terre de Feu, 91940 Les Ulis (France); Unité Mixte de Physique CNRS-Thales UMR 137, 1 avenue Augustin Fresnel, 91767 Palaiseau (France); Chrétien, Pascal; Schneegans, Olivier; Mencaraglia, Denis; Houzé, Frédéric, E-mail: frederic.houze@geeps.centralesupelec.fr [Laboratoire de Génie électrique et électronique de Paris (GeePs), UMR 8507 CNRS-CentraleSupélec, Paris-Sud and UPMC Universities, 11 rue Joliot-Curie, Plateau de Moulon, 91192 Gif-sur-Yvette (France); Delprat, Sophie [Unité Mixte de Physique CNRS-Thales UMR 137, 1 avenue Augustin Fresnel, 91767 Palaiseau (France); UPMC, Université Paris 06, 4 place Jussieu, 75005 Paris (France); Bouzehouane, Karim; Seneor, Pierre; Mattana, Richard [Unité Mixte de Physique CNRS-Thales UMR 137, 1 avenue Augustin Fresnel, 91767 Palaiseau (France); Tatay, Sergio [Molecular Science Institute, University of Valencia, 46980 Paterna (Spain); Geffroy, Bernard [Lab. Physique des Interfaces et Couches minces (PICM), UMR 7647 CNRS-École polytechnique, 91128 Palaiseau (France); Lab. d' Innovation en Chimie des Surfaces et Nanosciences (LICSEN), NIMBE UMR 3685 CNRS-CEA Saclay, 91191 Gif-sur-Yvette (France); and others

    2016-06-13

    An imaging technique associating a slowly intermittent contact mode of atomic force microscopy (AFM) with a home-made multi-purpose resistance sensing device is presented. It aims at extending the widespread resistance measurements classically operated in contact mode AFM to broaden their application fields to soft materials (molecular electronics, biology) and fragile or weakly anchored nano-objects, for which nanoscale electrical characterization is highly demanded and often proves to be a challenging task in contact mode. Compared with the state of the art concerning less aggressive solutions for AFM electrical imaging, our technique brings a significantly wider range of resistance measurement (over 10 decades) without any manual switching, which is a major advantage for the characterization of materials with large on-sample resistance variations. After describing the basics of the set-up, we report on preliminary investigations focused on academic samples of self-assembled monolayers with various thicknesses as a demonstrator of the imaging capabilities of our instrument, from qualitative and semi-quantitative viewpoints. Then two application examples are presented, regarding an organic photovoltaic thin film and an array of individual vertical carbon nanotubes. Both attest the relevance of the technique for the control and optimization of technological processes.

  18. Implant strategies for endocervical and interstitial ultrasound hyperthermia adjunct to HDR brachytherapy for the treatment of cervical cancer

    Energy Technology Data Exchange (ETDEWEB)

    Wootton, Jeffery H; Prakash, Punit; Hsu, I-Chow Joe; Diederich, Chris J, E-mail: CDiederich@radonc.ucsf.edu [Department of Radiation Oncology, University of California, San Francisco, CA 94115 (United States)

    2011-07-07

    Catheter-based ultrasound devices provide a method to deliver 3D conformable heating integrated with HDR brachytherapy delivery. Theoretical characterization of heating patterns was performed to identify implant strategies for these devices which can best be used to apply hyperthermia to cervical cancer. A constrained optimization-based hyperthermia treatment planning platform was used for the analysis. The proportion of tissue {>=}41 deg. C in a hyperthermia treatment volume was maximized with constraints T{sub max} {<=} 47 deg. C, T{sub rectum} {<=} 41.5 deg. C, and T{sub bladder} {<=} 42.5 deg. C. Hyperthermia treatment was modeled for generalized implant configurations and complex configurations from a database of patients (n = 14) treated with HDR brachytherapy. Various combinations of endocervical (360{sup 0} or 2 x 180{sup 0} output; 6 mm OD) and interstitial (180{sup 0}, 270{sup 0}, or 360{sup 0} output; 2.4 mm OD) applicators within catheter locations from brachytherapy implants were modeled, with perfusion constant (1 or 3 kg m{sup -3} s{sup -1}) or varying with location or temperature. Device positioning, sectoring, active length and aiming were empirically optimized to maximize thermal coverage. Conformable heating of appreciable volumes (>200 cm{sup 3}) is possible using multiple sectored interstitial and endocervical ultrasound devices. The endocervical device can heat >41 deg. C to 4.6 cm diameter compared to 3.6 cm for the interstitial. Sectored applicators afford tight control of heating that is robust to perfusion changes in most regularly spaced configurations. T{sub 90} in example patient cases was 40.5-42.7 deg. C (1.9-39.6 EM{sub 43deg.C}) at 1 kg m{sup -3} s{sup -1} with 10/14 patients {>=}41 deg. C. Guidelines are presented for positioning of implant catheters during the initial surgery, selection of ultrasound applicator configurations, and tailored power schemes for achieving T{sub 90} {>=} 41 deg. C in clinically practical implant

  19. SU-E-T-433: Pear-Shaped Based Dose Optimization for HDR Intracavitary Brachytherapy for Cervical Cancer Patients with Small Uterus.

    Science.gov (United States)

    Shen, S; Kim, R; Duan, J; Wu, X; Popple, R; Cardan, R; Brezovich, I

    2012-06-01

    Currently, CT has been widely used for HDR planning as MRI is not widely available for tumor imaging. Conventional pear-shaped isodose distribution may not be discarded completely because of possible microscopic diseases into parametrium/uterus. For patients with small uterus, organs at risk (OARs) can fall inside 100% conventional pear-shaped isodose-line. This study compares two pear-shaped based dose optimization methods for OARs sparing. Seven cervical cancer patients with small uterus were evaluated using 2 methods. For Method A, with conventional dwell-time loading, point A lateral distance was reduced until all OARs' D2cc were within the dose limits. For Method B, a reference target volume was generated using conventional pear-shaped 100% isodose- surface. While isodose-line near the point A was adjusted for OARs sparing, isodose-line surrounding ovoids were optimized to match the reference target volume. For equivalent OAR sparing, 100% isodose-line width (lateral dimension) at 1 cm inferior to point A (-1 cm) and at across centers of ovoids (ovoid) were compared between the 2 methods. OARs fall inside conventional 100% isodose-line in all cases. Median position of hot spots was 0.2 cm (range -;1.2 to 2.9 cm) superior to point A. Using Method A, point A lateral distance was adjusted to 1.4-1.7 cm for OARs sparing. Median width of 100% isodose-line was 5.82 cm at ovoid level, and 4.50 cm at -1 cm level. At ovoid level, median width of 100% isodose-line was reduced by 9(8-13)% for Method A, and was unchanged for Method B. At -1 cm level, median width of 100% isodose-line was reduced by 19(2- 33)% for Method A, and 11(0-15)% for Method B. for patients with small uterus, OARs are often fall inside 100% pear-s haped isodose-line near point A level. OARs can be spared without dramatically compromise treatment volume coverage around cervix using Method B. © 2012 American Association of Physicists in Medicine.

  20. IMPLEMENTATION AND EVALUATION OF A MOBILE MAPPING SYSTEM BASED ON INTEGRATED RANGE AND INTENSITY IMAGES FOR TRAFFIC SIGNS LOCALIZATION

    Directory of Open Access Journals (Sweden)

    M. Shahbazi

    2012-07-01

    Full Text Available Recent advances in positioning techniques have made it possible to develop Mobile Mapping Systems (MMS for detection and 3D localization of various objects from a moving platform. On the other hand, automatic traffic sign recognition from an equipped mobile platform has recently been a challenging issue for both intelligent transportation and municipal database collection. However, there are several inevitable problems coherent to all the recognition methods completely relying on passive chromatic or grayscale images. This paper presents the implementation and evaluation of an operational MMS. Being distinct from the others, the developed MMS comprises one range camera based on Photonic Mixer Device (PMD technology and one standard 2D digital camera. The system benefits from certain algorithms to detect, recognize and localize the traffic signs by fusing the shape, color and object information from both range and intensity images. As the calibrating stage, a self-calibration method based on integrated bundle adjustment via joint setup with the digital camera is applied in this study for PMD camera calibration. As the result, an improvement of 83 % in RMS of range error and 72 % in RMS of coordinates residuals for PMD camera, over that achieved with basic calibration is realized in independent accuracy assessments. Furthermore, conventional photogrammetric techniques based on controlled network adjustment are utilized for platform calibration. Likewise, the well-known Extended Kalman Filtering (EKF is applied to integrate the navigation sensors, namely GPS and INS. The overall acquisition system along with the proposed techniques leads to 90 % true positive recognition and the average of 12 centimetres 3D positioning accuracy.

  1. IMPLEMENTATION AND EVALUATION OF A MOBILE MAPPING SYSTEM BASED ON INTEGRATED RANGE AND INTENSITY IMAGES FOR TRAFFIC SIGNS LOCALIZATION

    Directory of Open Access Journals (Sweden)

    M. Shahbazi

    2012-07-01

    Full Text Available Recent advances in positioning techniques have made it possible to develop Mobile Mapping Systems (MMS for detection and 3D localization of various objects from a moving platform. On the other hand, automatic traffic sign recognition from an equipped mobile platform has recently been a challenging issue for both intelligent transportation and municipal database collection. However, there are several inevitable problems coherent to all the recognition methods completely relying on passive chromatic or grayscale images. This paper presents the implementation and evaluation of an operational MMS. Being distinct from the others, the developed MMS comprises one range camera based on Photonic Mixer Device (PMD technology and one standard 2D digital camera. The system benefits from certain algorithms to detect, recognize and localize the traffic signs by fusing the shape, color and object information from both range and intensity images. As the calibrating stage, a self-calibration method based on integrated bundle adjustment via joint setup with the digital camera is applied in this study for PMD camera calibration. As the result, an improvement of 83% in RMS of range error and 72% in RMS of coordinates residuals for PMD camera, over that achieved with basic calibration is realized in independent accuracy assessments. Furthermore, conventional photogrammetric techniques based on controlled network adjustment are utilized for platform calibration. Likewise, the well-known Extended Kalman Filtering (EKF is applied to integrate the navigation sensors, namely GPS and INS. The overall acquisition system along with the proposed techniques leads to 90% true positive recognition and the average of 12 centimetres 3D positioning accuracy.

  2. Investigation of Range Profiles from a Simplified Ship on Rough Sea Surface and Its Multipath Imaging Mechanisms

    Directory of Open Access Journals (Sweden)

    Siyuan He

    2012-01-01

    Full Text Available The range profiles of a two-dimension (2 D perfect electric conductor (PEC ship on a wind-driven rough sea surface are derived by performing an inverse discrete Fourier transform (IDFT on the wide band backscattered field. The rough sea surface is assuming to be a PEC surface. The back scattered field is computed based on EM numerical simulation when the frequencies are sampled between 100 MHz and 700 MHz. Considering the strong coupling interactions between the ship and sea, the complicated multipath effect to the range profile characteristics is fully analyzed based on the multipath imaging mechanisms. The coupling mechanisms could be explained by means of ray theory prediction and numerical extraction of the coupling currents. The comparison of the range profile locations between ray theory prediction and surface current simulation is implemented and analyzed in this paper. Finally, the influence of different sea states on the radar target signatures has been examined and discussed.

  3. Enhanced Vitreous Imaging in Healthy Eyes Using Swept Source Optical Coherence Tomography

    Science.gov (United States)

    Liu, Jonathan J.; Witkin, Andre J.; Adhi, Mehreen; Grulkowski, Ireneusz; Kraus, Martin F.; Dhalla, Al-Hafeez; Lu, Chen D.; Hornegger, Joachim; Duker, Jay S.; Fujimoto, James G.

    2014-01-01

    Purpose To describe enhanced vitreous imaging for visualization of anatomic features and microstructures within the posterior vitreous and vitreoretinal interface in healthy eyes using swept-source optical coherence tomography (SS-OCT). The study hypothesis was that long-wavelength, high-speed, volumetric SS-OCT with software registration motion correction and vitreous window display or high-dynamic-range (HDR) display improves detection sensitivity of posterior vitreous and vitreoretinal features compared to standard OCT logarithmic scale display. Design Observational prospective cross-sectional study. Methods Multiple wide-field three-dimensional SS-OCT scans (500×500A-scans over 12×12 mm2) were obtained using a prototype instrument in 22 eyes of 22 healthy volunteers. A registration motion-correction algorithm was applied to compensate motion and generate a single volumetric dataset. Each volumetric dataset was displayed in three forms: (1) standard logarithmic scale display, enhanced vitreous imaging using (2) vitreous window display and (3) HDR display. Each dataset was reviewed independently by three readers to identify features of the posterior vitreous and vitreoretinal interface. Detection sensitivities for these features were measured for each display method. Results Features observed included the bursa premacularis (BPM), area of Martegiani, Cloquet's/BPM septum, Bergmeister papilla, posterior cortical vitreous (hyaloid) detachment, papillomacular hyaloid detachment, hyaloid attachment to retinal vessel(s), and granular opacities within vitreous cortex, Cloquet's canal, and BPM. The detection sensitivity for these features was 75.0% (95%CI: 67.8%–81.1%) using standard logarithmic scale display, 80.6% (95%CI: 73.8%–86.0%) using HDR display, and 91.9% (95%CI: 86.6%–95.2%) using vitreous window display. Conclusions SS-OCT provides non-invasive, volumetric and measurable in vivo visualization of the anatomic microstructural features of the posterior

  4. Enhanced vitreous imaging in healthy eyes using swept source optical coherence tomography.

    Directory of Open Access Journals (Sweden)

    Jonathan J Liu

    Full Text Available To describe enhanced vitreous imaging for visualization of anatomic features and microstructures within the posterior vitreous and vitreoretinal interface in healthy eyes using swept-source optical coherence tomography (SS-OCT. The study hypothesis was that long-wavelength, high-speed, volumetric SS-OCT with software registration motion correction and vitreous window display or high-dynamic-range (HDR display improves detection sensitivity of posterior vitreous and vitreoretinal features compared to standard OCT logarithmic scale display.Observational prospective cross-sectional study.Multiple wide-field three-dimensional SS-OCT scans (500×500A-scans over 12×12 mm2 were obtained using a prototype instrument in 22 eyes of 22 healthy volunteers. A registration motion-correction algorithm was applied to compensate motion and generate a single volumetric dataset. Each volumetric dataset was displayed in three forms: (1 standard logarithmic scale display, enhanced vitreous imaging using (2 vitreous window display and (3 HDR display. Each dataset was reviewed independently by three readers to identify features of the posterior vitreous and vitreoretinal interface. Detection sensitivities for these features were measured for each display method.Features observed included the bursa premacularis (BPM, area of Martegiani, Cloquet's/BPM septum, Bergmeister papilla, posterior cortical vitreous (hyaloid detachment, papillomacular hyaloid detachment, hyaloid attachment to retinal vessel(s, and granular opacities within vitreous cortex, Cloquet's canal, and BPM. The detection sensitivity for these features was 75.0% (95%CI: 67.8%-81.1% using standard logarithmic scale display, 80.6% (95%CI: 73.8%-86.0% using HDR display, and 91.9% (95%CI: 86.6%-95.2% using vitreous window display.SS-OCT provides non-invasive, volumetric and measurable in vivo visualization of the anatomic microstructural features of the posterior vitreous and vitreoretinal interface. The

  5. TU-FG-BRB-09: Thermoacoustic Range Verification with Perfect Co-Registered Overlay of Bragg Peak onto Ultrasound Image

    Energy Technology Data Exchange (ETDEWEB)

    Patch, S; Kireeff Covo, M; Jackson, A; Qadadha, Y; Campbell, K; Albright, R; Bloemhard, P; Donoghue, A; Siero, C; Gimpel, T; Small, S; Ninemire, B; Johnson, M; Phair, L [Lawrence Berkeley National Lab, Berkeley, CA (United States)

    2016-06-15

    Purpose: The potential of particle therapy has not yet been fully realized due to inaccuracies in range verification. The purpose of this work was to correlate the Bragg peak location with target structure, by overlaying thermoacoustic localization of the Bragg peak onto an ultrasound image. Methods: Pulsed delivery of 50 MeV protons was accomplished by a fast chopper installed between the ion source and the inflector of the 88″ cyclotron at Lawrence Berkeley National Lab. 2 Gy were delivered in 2 µs by a beam with peak current of 2 µA. Thermoacoustic emissions were detected by a cardiac array and Verasonics V1 ultrasound system, which also generated a grayscale ultrasound image. 1024 thermoacoustic pulses were averaged before filtering and one-way beamforming focused signal onto the Bragg peak location with perfect co-registration to the ultrasound images. Data was collected in a room temperature water bath and gelatin phantom with a cavity designed to mimic the intestine, in which gas pockets can displace the Bragg peak. Experiments were performed with the cavity both empty and filled with olive oil. Results: In the waterbath overlays of the Bragg peak agreed with Monte Carlo simulations to within 800±170 µm. Agreement within 1.3 ± 0.2 mm was achieved in the gelatin phantom, although relative stopping powers were estimated only to first order from CT scans. Protoacoustic signals were detected after travel from the Bragg peak through 29 mm and 65 mm of phantom material when the cavity was empty and full of olive oil, respectively. Conclusion: Protoacoustic range verification is feasible with a commercial clinical ultrasound array, but at doses exceeding the clinical realm. Further optimization of both transducer array and injection line chopper is required to enable range verification within a 2 Gy dose limit, which would enable online adaptive treatment. This work was supported in part by a UWM Intramural Instrumentation Grant and by the Director, Office

  6. Prostate Specific Antigen (PSA as Predicting Marker for Clinical Outcome and Evaluation of Early Toxicity Rate after High-Dose Rate Brachytherapy (HDR-BT in Combination with Additional External Beam Radiation Therapy (EBRT for High Risk Prostate Cancer

    Directory of Open Access Journals (Sweden)

    Thorsten H. Ecke

    2016-11-01

    Full Text Available High-dose-rate brachytherapy (HDR-BT with external beam radiation therapy (EBRT is a common treatment option for locally advanced prostate cancer (PCa. Seventy-nine male patients (median age 71 years, range 50 to 79 with high-risk PCa underwent HDR-BT following EBRT between December 2009 and January 2016 with a median follow-up of 21 months. HDR-BT was administered in two treatment sessions (one week interval with 9 Gy per fraction using a planning system and the Ir192 treatment unit GammaMed Plus iX. EBRT was performed with CT-based 3D-conformal treatment planning with a total dose administration of 50.4 Gy with 1.8 Gy per fraction and five fractions per week. Follow-up for all patients was organized one, three, and five years after radiation therapy to evaluate early and late toxicity side effects, metastases, local recurrence, and prostate-specific antigen (PSA value measured in ng/mL. The evaluated data included age, PSA at time of diagnosis, PSA density, BMI (body mass index, Gleason score, D’Amico risk classification for PCa, digital rectal examination (DRE, PSA value after one/three/five year(s follow-up (FU, time of follow-up, TNM classification, prostate volume, and early toxicity rates. Early toxicity rates were 8.86% for gastrointestinal, and 6.33% for genitourinary side effects. Of all treated patients, 84.81% had no side effects. All reported complications in early toxicity were grade 1. PSA density at time of diagnosis (p = 0.009, PSA on date of first HDR-BT (p = 0.033, and PSA on date of first follow-up after one year (p = 0.025 have statistical significance on a higher risk to get a local recurrence during follow-up. HDR-BT in combination with additional EBRT in the presented design for high-risk PCa results in high biochemical control rates with minimal side-effects. PSA is a negative predictive biomarker for local recurrence during follow-up. A longer follow-up is needed to assess long-term outcome and toxicities.

  7. Prostate Specific Antigen (PSA) as Predicting Marker for Clinical Outcome and Evaluation of Early Toxicity Rate after High-Dose Rate Brachytherapy (HDR-BT) in Combination with Additional External Beam Radiation Therapy (EBRT) for High Risk Prostate Cancer.

    Science.gov (United States)

    Ecke, Thorsten H; Huang-Tiel, Hui-Juan; Golka, Klaus; Selinski, Silvia; Geis, Berit Christine; Koswig, Stephan; Bathe, Katrin; Hallmann, Steffen; Gerullis, Holger

    2016-11-10

    High-dose-rate brachytherapy (HDR-BT) with external beam radiation therapy (EBRT) is a common treatment option for locally advanced prostate cancer (PCa). Seventy-nine male patients (median age 71 years, range 50 to 79) with high-risk PCa underwent HDR-BT following EBRT between December 2009 and January 2016 with a median follow-up of 21 months. HDR-BT was administered in two treatment sessions (one week interval) with 9 Gy per fraction using a planning system and the Ir192 treatment unit GammaMed Plus iX. EBRT was performed with CT-based 3D-conformal treatment planning with a total dose administration of 50.4 Gy with 1.8 Gy per fraction and five fractions per week. Follow-up for all patients was organized one, three, and five years after radiation therapy to evaluate early and late toxicity side effects, metastases, local recurrence, and prostate-specific antigen (PSA) value measured in ng/mL. The evaluated data included age, PSA at time of diagnosis, PSA density, BMI (body mass index), Gleason score, D'Amico risk classification for PCa, digital rectal examination (DRE), PSA value after one/three/five year(s) follow-up (FU), time of follow-up, TNM classification, prostate volume, and early toxicity rates. Early toxicity rates were 8.86% for gastrointestinal, and 6.33% for genitourinary side effects. Of all treated patients, 84.81% had no side effects. All reported complications in early toxicity were grade 1. PSA density at time of diagnosis (p = 0.009), PSA on date of first HDR-BT (p = 0.033), and PSA on date of first follow-up after one year (p = 0.025) have statistical significance on a higher risk to get a local recurrence during follow-up. HDR-BT in combination with additional EBRT in the presented design for high-risk PCa results in high biochemical control rates with minimal side-effects. PSA is a negative predictive biomarker for local recurrence during follow-up. A longer follow-up is needed to assess long-term outcome and toxicities.

  8. First-order convex feasibility algorithms for iterative image reconstruction in limited angular-range X-ray CT

    CERN Document Server

    Sidky, Emil Y; Pan, Xiaochuan

    2012-01-01

    Iterative image reconstruction (IIR) algorithms in Computed Tomography (CT) are based on algorithms for solving a particular optimization problem. Design of the IIR algorithm, therefore, is aided by knowledge of the solution to the optimization problem on which it is based. Often times, however, it is impractical to achieve accurate solution to the optimization of interest, which complicates design of IIR algorithms. This issue is particularly acute for CT with a limited angular-range scan, which leads to poorly conditioned system matrices and difficult to solve optimization problems. In this article, we develop IIR algorithms which solve a certain type of optimization called convex feasibility. The convex feasibility approach can provide alternatives to unconstrained optimization approaches and at the same time allow for efficient algorithms for their solution -- thereby facilitating the IIR algorithm design process. An accelerated version of the Chambolle-Pock (CP) algorithm is adapted to various convex fea...

  9. Image quality, meteorological optical range, and fog particulate number evaluation using the Sandia National Laboratories fog chamber

    Science.gov (United States)

    Birch, Gabriel C.; Woo, Bryana L.; Sanchez, Andres L.; Knapp, Haley

    2017-08-01

    The evaluation of optical system performance in fog conditions typically requires field testing. This can be challenging due to the unpredictable nature of fog generation and the temporal and spatial nonuniformity of the phenomenon itself. We describe the Sandia National Laboratories fog chamber, a new test facility that enables the repeatable generation of fog within a 55 m×3 m×3 m (L×W×H) environment, and demonstrate the fog chamber through a series of optical tests. These tests are performed to evaluate system image quality, determine meteorological optical range (MOR), and measure the number of particles in the atmosphere. Relationships between typical optical quality metrics, MOR values, and total number of fog particles are described using the data obtained from the fog chamber and repeated over a series of three tests.

  10. Wide range instantaneous temperature measurements of convective fluid flows by using a schlieren system based in color images

    Science.gov (United States)

    Martínez-González, A.; Moreno-Hernández, D.; Monzón-Hernández, D.; León-Rodríguez, M.

    2017-06-01

    In the schlieren method, the deflection of light by the presence of an inhomogeneous medium is proportional to the gradient of its refractive index. Such deflection, in a schlieren system, is represented by light intensity variations on the observation plane. Then, for a digital camera, the intensity level registered by each pixel depends mainly on the variation of the medium refractive index and the status of the digital camera settings. Therefore, in this study, we regulate the intensity value of each pixel by controlling the camera settings such as exposure time, gamma and gain values in order to calibrate the image obtained to the actual temperature values of a particular medium. In our approach, we use a color digital camera. The images obtained with a color digital camera can be separated on three different color-channels. Each channel corresponds to red, green, and blue color, moreover, each one has its own sensitivity. The differences in sensitivity allow us to obtain a range of temperature values for each color channel. Thus, high, medium and low sensitivity correspond to green, blue, and red color channel respectively. Therefore, by adding up the temperature contribution of each color channel we obtain a wide range of temperature values. Hence, the basic idea in our approach to measure temperature, using a schlieren system, is to relate the intensity level of each pixel in a schlieren image to the corresponding knife-edge position measured at the exit focal plane of the system. Our approach was applied to the measurement of instantaneous temperature fields of the air convection caused by a heated rectangular metal plate and a candle flame. We found that for the metal plate temperature measurements only the green and blue color-channels were required to sense the entire phenomena. On the other hand, for the candle case, the three color-channels were needed to obtain a complete measurement of temperature. In our study, the candle temperature was took as

  11. Modeling LCD Displays with Local Backlight Dimming for Image Quality Assessment

    DEFF Research Database (Denmark)

    Korhonen, Jari; Burini, Nino; Forchhammer, Søren

    2011-01-01

    for evaluating the signal quality distortion related directly to digital signal processing, such as compression. However, the physical characteristics of the display device also pose a significant impact on the overall perception. In order to facilitate image quality assessment on modern liquid crystaldisplays......Traditionally, algorithm-based (objective) image and video quality assessment methods operate with the numerical presentation of the signal, and they do not take the characteristics of the actual output device into account. This is a reasonable approach, when quality assessment is needed...... (LCD) using light emitting diode (LED) backlight with local dimming, we present the essential considerations and guidelines for modeling the characteristics of displays with high dynamic range (HDR) and locally adjustable backlight segments. The representation of the image generated by the model can...

  12. SU-E-T-509: Inter-Observer and Inter-Modality Contouring Analysis for Organs at Risk for HDR Gynecological Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Sadeghi, P; Smith, W [University of Calgary, Calgary, AB (Canada); Tom Baker Cancer Centre, Calgary, AB (Canada); Banerjee, R; Alghamdi, M; Phan, T; Taggar, A [University of Calgary, Calgary, AB (Canada)

    2015-06-15

    Purpose This study quantifies errors associated with MR-guided High Dose Rate (HDR) gynecological brachytherapy. Uncertainties in this treatment results from contouring, organ motion between imaging and treatment delivery, dose calculation, and dose delivery. We focus on interobserver and inter-modality variability in contouring and the motion of organs at risk (OARs) in the time span between the MR and CT scans (∼1 hour). We report the change in organ volume and position of center of mass (CM) between the two imaging modalities. Methods A total of 8 patients treated with MR-guided HDR brachytherapy were included in this study. Two observers contoured the bladder and rectum on both MR and CT scans. The change in OAR volume and CM position between the MR and CT imaging sessions on both image sets were calculated. Results The absolute mean bladder volume change between the two imaging modalities is 67.1cc. The absolute mean inter-observer difference in bladder volume is much lower at 15.5cc (MR) and 11.0cc (CT). This higher inter-modality volume difference suggests a real change in the bladder filling between the two imaging sessions. Change in Rectum volume inter-observer standard error of means (SEM) is 3.18cc (MR) and 3.09cc (CT), while the inter-modality SEM is 3.65cc (observer 1), and 2.75cc (observer 2). The SEM for rectum CM position in the superior-inferior direction was approximately three times higher than in other directions for both the inter—observer (0.77 cm, 0.92 cm for observers 1 and 2, respectively) and inter-modality (0.91 cm, 0.95 cm for MR and CT, respectively) variability. Conclusion Bladder contours display good consistency between different observers on both CT and MR images. For rectum contouring the highest inconsistency stems from the observers’ choice of the superior-inferior borders. A complete analysis of a larger patient cohort will enable us to separate the true organ motion from the inter-observer variability.

  13. Calibration of imaging plate detectors to mono-energetic protons in the range 1-200 MeV

    Science.gov (United States)

    Rabhi, N.; Batani, D.; Boutoux, G.; Ducret, J.-E.; Jakubowska, K.; Lantuejoul-Thfoin, I.; Nauraye, C.; Patriarca, A.; Saïd, A.; Semsoum, A.; Serani, L.; Thomas, B.; Vauzour, B.

    2017-11-01

    Responses of Fuji Imaging Plates (IPs) to proton have been measured in the range 1-200 MeV. Mono-energetic protons were produced with the 15 MV ALTO-Tandem accelerator of the Institute of Nuclear Physics (Orsay, France) and, at higher energies, with the 200-MeV isochronous cyclotron of the Institut Curie—Centre de Protonthérapie d'Orsay (Orsay, France). The experimental setups are described and the measured photo-stimulated luminescence responses for MS, SR, and TR IPs are presented and compared to existing data. For the interpretation of the results, a sensitivity model based on the Monte Carlo GEANT4 code has been developed. It enables the calculation of the response functions in a large energy range, from 0.1 to 200 MeV. Finally, we show that our model reproduces accurately the response of more complex detectors, i.e., stack of high-Z filters and IPs, which could be of great interest for diagnostics of Petawatt laser accelerated particles.

  14. Comprehensive analysis of proton range uncertainties related to stopping-power-ratio estimation using dual-energy CT imaging

    Science.gov (United States)

    Li, B.; Lee, H. C.; Duan, X.; Shen, C.; Zhou, L.; Jia, X.; Yang, M.

    2017-09-01

    The dual-energy CT-based (DECT) approach holds promise in reducing the overall uncertainty in proton stopping-power-ratio (SPR) estimation as compared to the conventional stoichiometric calibration approach. The objective of this study was to analyze the factors contributing to uncertainty in SPR estimation using the DECT-based approach and to derive a comprehensive estimate of the range uncertainty associated with SPR estimation in treatment planning. Two state-of-the-art DECT-based methods were selected and implemented on a Siemens SOMATOM Force DECT scanner. The uncertainties were first divided into five independent categories. The uncertainty associated with each category was estimated for lung, soft and bone tissues separately. A single composite uncertainty estimate was eventually determined for three tumor sites (lung, prostate and head-and-neck) by weighting the relative proportion of each tissue group for that specific site. The uncertainties associated with the two selected DECT methods were found to be similar, therefore the following results applied to both methods. The overall uncertainty (1σ) in SPR estimation with the DECT-based approach was estimated to be 3.8%, 1.2% and 2.0% for lung, soft and bone tissues, respectively. The dominant factor contributing to uncertainty in the DECT approach was the imaging uncertainties, followed by the DECT modeling uncertainties. Our study showed that the DECT approach can reduce the overall range uncertainty to approximately 2.2% (2σ) in clinical scenarios, in contrast to the previously reported 1%.

  15. Preliminary study of a new gamma imager for on-line proton range monitoring during proton radiotherapy

    Science.gov (United States)

    Bennati, P.; Dasu, A.; Colarieti-Tosti, M.; Lönn, G.; Larsson, D.; Fabbri, A.; Galasso, M.; Cinti, M. N.; Pellegrini, R.; Pani, R.

    2017-05-01

    We designed and tested new concept imaging devices, based on a thin scintillating crystal, aimed at the online monitoring of the range of protons in tissue during proton radiotherapy. The proposed crystal can guarantee better spatial resolution and lower sensitivity with respect to a thicker one, at the cost of a coarser energy resolution. Two different samples of thin crystals were coupled to a position sensitive photo multiplier tube read out by 64 independent channels electronics. The detector was equipped with a knife-edge Lead collimator that defined a reasonable field of view of about 10 cm in the target. Geant4 Monte Carlo simulations were used to optimize the design of the experimental setup and assess the accuracy of the results. Experimental measurements were carried out at the Skandion Clinic, the recently opened proton beam facility in Uppsala, Sweden. PMMA and water phantoms studies were performed with a first prototype based on a round 6.0 mm thick Cry019 crystal and with a second detector based on a thinner 5 × 5 cm2, 2.0 mm thick LFS crystal. Phantoms were irradiated with mono-energetic proton beams whose energy was in the range between 110 and 160 MeV. According with the simulations and the experimental data, the detector based on LFS crystal seems able to identify the peak of prompt-gamma radiation and its results are in fair agreement with the expected shift of the proton range as a function of energy. The count rate remains one of the most critical limitations of our system, which was able to cope with only about 20% of the clinical dose rate. Nevertheless, we are confident that our study might provide the basis for developing a new full-functional system.

  16. SU-F-T-63: Dosimetric Relevance of the Valencia and Leipzig HDR Applicators Plastic Cap

    Energy Technology Data Exchange (ETDEWEB)

    Granero, D [ERESA-Hospital General Universitario, Valencia (Spain); Candela-Juan, C [National Dosimetry Centre (CND), Valencia (Spain); Vijande, J; Ballester, F [University of Valencia, Burjassot (Spain); Perez-Calatayud, J [Hospital La Fe, Valencia (Spain); Jacob, D; Mourtada, F [Helen F. Graham Cancer Center, Christiana Care Health System, Newark, DE (United States)

    2016-06-15

    Purpose: Utilization of HDR brachytherapy treatment of skin lesions using collimated applicators, such as the Valencia or Leipzig is increasing. These applicators are made of cup-shaped tungsten material in order to focalize the radiation into the lesion and to protect nearby tissues. These applicators have an attachable plastic cap that removes secondary electrons generated in the applicator and flattens the treatment surface. The purpose of this study is to examine the dosimetric impact of this cap, and the effect if the cap is not placed during the HDR fraction delivery. Methods: Monte Carlo simulations have been done using the code Geant4 for the Valencia and Leipzig applicators. Dose rate distributions have been obtained for the applicators with and without the plastic cap. An experimental study using EBT3 radiochromic film has been realized in order to verify the Monte Carlo results. Results: The Monte Carlo simulations show that absorbed dose in the first millimeter of skin can increase up to 180% for the Valencia applicator if the plastic cap is absent and up to 1500% for the Leipzig applicators. At deeper distances the increase of dose is smaller being about 10–15%. Conclusion: Important differences have been found if the plastic cap of the applicators is absent in the treatment producing an overdosage in the skin. The user should have a checklist to remind him check always before HDR fraction delivery to insure the plastic cap is placed on the applicator. This work was supported in part by Generalitat Valenciana under Project PROMETEOII/2013/010, by the Spanish Government under Project No. FIS2013-42156, and by a research agreement with Elekta Brachytherapy, Veenendaal, The Netherlands.

  17. SU-F-T-14: Dosimetric Impacts of Various Uncertainties in Cervical Cancer HDR Brachytherapy: Are Conventional Point Doses Good Surrogates for 3D Dosimetry?

    Energy Technology Data Exchange (ETDEWEB)

    Liang, X; Li, Z [University of Florida Health Proton Therapy Institute, Jacksonville, FL (United States); Zheng, D [University of Nebraska Medical Center, Omaha, NE (United States); Zhang, X; Narayanasamy, G; Morrill, S; Penagaricano, J; Paudel, N [University of Arkansas for Medical Sciences, Little Rock, AR (United States)

    2016-06-15

    Purpose: In the context of evaluating dosimetric impacts of a variety of uncertainties involved in HDR Tandem-and-Ovoid treatment, to study the correlations between conventional point doses and 3D volumetric doses. Methods: For 5 cervical cancer patients treated with HDR T&O, 150 plans were retrospectively created to study dosimetric impacts of the following uncertainties: (1) inter-fractional applicator displacement between two treatment fractions within a single insertion by applying Fraction#1 plan to Fraction#2 CT; (2) positional dwell error simulated from −5mm to 5mm in 1mm steps; (3) simulated temporal dwell error of 0.05s, 0.1s, 0.5s, and 1s. The original plans were based on point dose prescription, from which the volume covered by the prescription dose was generated as the pseudo target volume to study the 3D target dose effect. OARs were contoured. The point and volumetric dose errors were calculated by taking the differences between original and simulated plans. The correlations between the point and volumetric dose errors were analyzed. Results: For the most clinically relevant positional dwell uncertainty of 1mm, temporal uncertainty of 0.05s, and inter-fractional applicator displacement within the same insertion, the mean target D90 and V100 deviation were within 1%. Among these uncertainties, the applicator displacement showed the largest potential target coverage impact (2.6% on D90) as well as the OAR dose impact (2.5% and 3.4% on bladder D2cc and rectum D2cc). The Spearman correlation analysis shows a correlation coefficient of 0.43 with a p-value of 0.11 between target D90 coverage and H point dose. Conclusion: With the most clinically relevant positional and temporal dwell uncertainties and patient interfractional applicator displacement within the same insertion, the dose error is within clinical acceptable range. The lack of correlation between H point and 3D volumetric dose errors is a motivator for the use of 3D treatment planning in

  18. Robust Estimation of HDR in fMRI using H-infinity Filters

    DEFF Research Database (Denmark)

    Puthusserypady, Sadasivan; Jue, R.; Ratnarajah, T.

    2010-01-01

    . The H8 approach is used because it safeguards against the worst case disturbances and makes no assumptions on the (statistical) nature of the signals [B. Hassibi and T. Kailath, in Proc. ICASSP, 1995, vol. 2, pp. 949-952; T. Ratnarajah and S. Puthusserypady, in Proc. 8th IEEEWorkshopDSP, 1998, pp. 1483......-1487]. Performances of the proposed techniques are compared to the conventional t-test method as well as the well-known LMSs and recursive least squares algorithms. Extensive numerical simulations show that the proposed methods result in better HDR estimations and activation detections....

  19. Imaging X-ray detector front-end with high dynamic range: IDeF-X HD

    Science.gov (United States)

    Gevin, O.; Lemaire, O.; Lugiez, F.; Michalowska, A.; Baron, P.; Limousin, O.; Delagnes, E.

    2012-12-01

    Presented circuit, IDeF-X HD (Imaging Detector Front-end) is a member of the IDeF-X ASICs family for space applications. It has been optimized for a half millimeter pitch CdTe or CdZnTe pixelated detector arranged in 16×16 array. It is aimed to operate in the hard X-ray range from few keV up to 250 keV or more. The ASIC has been realized in AMS 0.35 μm CMOS process. The IDeF-X HD is a 32 channel analog front-end with self-triggering capability. The architecture of the analog channel includes a chain of charge sensitive amplifier with continuous reset system and non-stationary noise suppressor, adjustable gain stage, pole-zero cancellation stage, adjustable shaping time low pass filter, baseline holder and peak detector with discriminator. The power consumption of the IDeF-X HD is 800 μW per channel. With the in-channel variable gain stage the nominal 250 keV dynamic range of the ASIC can be extended up to 1 MeV anticipating future applications using thick sensors. Measuring the noise performance without a detector at the input with minimized leakage current (programmable) at the input, we achieved ENC of 33 electrons rms at 10.7 μs peak time. Measurements with CdTe detector show good energy resolution FWHM of 1.1 keV at 60 keV and 4.3 keV at 662 keV with detection threshold below 4 keV. In addition, an absolute temperature sensor has been integrated with resolution of 1.5 °C.

  20. A semi-automatic image-based close range 3D modeling pipeline using a multi-camera configuration

    National Research Council Canada - National Science Library

    Rau, Jiann-Yeou; Yeh, Po-Chia

    2012-01-01

    .... This study proposes an image-based 3D modeling pipeline which takes advantage of a multi-camera configuration and multi-image matching technique that does not require any markers on or around the object...

  1. Time-resolved imaging of prompt-gamma rays for proton range verification using a knife-edge slit camera based on digital photon counters

    NARCIS (Netherlands)

    Cambraia Lopes, P.; Clementel, E.; Crespo, P.; Henrotin, S.; Huizenga, J.; Janssens, G.; Parodi, K.; Prieels, D.; Roellinghoff, F.; Smeets, J.; Stichelbaut, F.; Schaart, D.R.

    2015-01-01

    Proton range monitoring may facilitate online adaptive proton therapy and improve treatment outcomes. Imaging of proton-induced prompt gamma (PG) rays using a knife-edge slit collimator is currently under investigation as a potential tool for real-time proton range monitoring. A major challenge in

  2. Fusion of range-based data and image-based datasets for efficient documentation of cultural heritage objects and sites

    Science.gov (United States)

    Lerma, J. L.; Cabrelles, M.; Navarro, S.

    2015-08-01

    Nowadays it is possible to measure accurately dense point clouds either with aerial/terrestrial laser scanning systems or with imagebased solutions (namely based on photogrammetric computer vision algorithms such as structure-from-motion (SfM)), from which highly detailed 3D models can be achieved. Besides, direct tools in the form of simple devices such as rulers, compass and plumblines are usually required in simple metric surveys, as well as high-end surveying and geodetic instruments such as robotized imagebased total stations and GNSS (probably to a lesser degree but still required) to set the archaeological/architectural recording project in a global reference frame. With all this gamut of image-based and range-based sensors and datasets (in the form of coordinates, point clouds or 3D models), in different coordinate systems (most of the times local for each device), lack of uniform scale, orientation and levelling, the fusion of data tends to be cumbersome. This paper presents an efficient way to fuse and merge different datasets in the form of point clouds/3D models and geodetic/UTM coordinates. The new developed 3DVEM - Register GEO software is able to handle datasets coming from both direct and indirect methods in order to provide unified and precise deliverables.

  3. Ultrahigh polarimetric image contrast enhancement for skin cancer diagnosis using InN plasmonic nanoparticles in the terahertz range.

    Science.gov (United States)

    Ney, Michael; Abdulhalim, Ibrahim

    2015-01-01

    Mueller matrix imaging sensitivity, to delicate water content changes in tissue associated with early stages of skin cancer, is demonstrated by numerical modeling to be enhanced by localized surface plasmon resonance (LSPR) effects at the terahertz (THz) range when InN nanoparticles (NPs) coated with Parylene-C are introduced into the skin. A skin tissue model tailored for THz wavelengths is established for a Monte Carlo simulation of polarized light propagation and scattering, and a comparative study based on simulated Mueller matrices is presented considering different NPs’ parameters and insertion into the skin methods. The insertion of NPs presenting LSPR in the THz is demonstrated to enable the application of polarization-based sample characterization techniques adopted from the scattering dominated visible wavelengths domain for the, otherwise, relatively low scattering THz domain, where such approach is irrelevant without the NPs. Through these Mueller polarimetry techniques, the detection of water content variations in the tissue is made possible and with high sensitivity. This study yields a limit of detection down to 0.0018% for relative changes in the water content based on linear degree of polarization--an improvement of an order of magnitude relative to the limit of detection without NPs calculated in a previous ellipsometric study.

  4. Organic Analysis in the Miller Range 090657 CR2 Chondrite: Part 3 C and N Isotopic Imaging

    Science.gov (United States)

    Messenger, S.; Nakamura-Messenger, K.; Elsila, J. E.; Berger, E. L.; Burton, A. S.; Clemett, S. J.; Cao, T.

    2016-01-01

    Primitive carbonaceous chondrites contain a wide variety of organic material, ranging from soluble discrete molecules to insoluble nanoglobules of macro-molecular carbon. The relationship between the soluble organic molecules, macromolecular organic material, and host minerals are poorly understood. Large H, C and N isotopic anomalies suggest some organic components formed in low-T interstellar or outer Solar System environments. The highest isotope anomalies occur in m-scale inclusions in the most primitive materials, such as cometary dust and the least altered carbonaceous chondrites. Often, the hosts of these isotopically anomalous 'hotspots' are discrete organic nanoglobules that probably formed in the outermost reaches of the protosolar disk or cold molecular cloud. Molecular and isotopic studies of meteoritic organic matter are aimed at identifying the chemical properties and formation processes of interstellar organic materials and the subsequent chemical evolutionary pathways in various Solar System environments. The combination of soluble and insoluble analyses with in situ and bulk studies provides powerful constraints on the origin and evolution of organic matter in the Solar System. Using macroscale extraction and analysis techniques as well as microscale in situ observations we have been studying both insoluble and soluble organic material in primitive astromaterial samples. Here, we present results of bulk C and N isotopic measurements and coordinated in situ C and N isotopic imaging and mineralogical and textural studies of carbonaceous materials in a Cr2 carbonaceous chondrite. In accompanying abstracts we discuss the morphology and distribution of carbonaceous components and soluble organic species of this meteorite.

  5. Three-dimensional anterior segment imaging in patients with type 1 Boston Keratoprosthesis with switchable full depth range swept source optical coherence tomography

    Science.gov (United States)

    Poddar, Raju; Cortés, Dennis E.; Werner, John S.; Mannis, Mark J.; Zawadzki, Robert J.

    2013-08-01

    A high-speed (100 kHz A-scans/s) complex conjugate resolved 1 μm swept source optical coherence tomography (SS-OCT) system using coherence revival of the light source is suitable for dense three-dimensional (3-D) imaging of the anterior segment. The short acquisition time helps to minimize the influence of motion artifacts. The extended depth range of the SS-OCT system allows topographic analysis of clinically relevant images of the entire depth of the anterior segment of the eye. Patients with the type 1 Boston Keratoprosthesis (KPro) require evaluation of the full anterior segment depth. Current commercially available OCT systems are not suitable for this application due to limited acquisition speed, resolution, and axial imaging range. Moreover, most commonly used research grade and some clinical OCT systems implement a commercially available SS (Axsun) that offers only 3.7 mm imaging range (in air) in its standard configuration. We describe implementation of a common swept laser with built-in k-clock to allow phase stable imaging in both low range and high range, 3.7 and 11.5 mm in air, respectively, without the need to build an external MZI k-clock. As a result, 3-D morphology of the KPro position with respect to the surrounding tissue could be investigated in vivo both at high resolution and with large depth range to achieve noninvasive and precise evaluation of success of the surgical procedure.

  6. Spherical Panoramas, and non Metric Images for Long Range Survey, the San Barnaba Spire, Sagrada Familia, Barcelona, Spain

    Directory of Open Access Journals (Sweden)

    Elisa Cingolani

    2011-12-01

    consist basically in the difficulty given by its height above the street level, about 100 meters. Long focal lenses have to be used to get a suitable resolution and accuracy. We wanted to repeat now the survey using a different photogrammetric technique from the old one, that was DLT algorithm for non-metric images. The new technique is the Spherical Photogrammetry. Multi-image Spherical Photogrammetry makes use as sensor of a pseudo-image that is the spherical panorama, composed by the images taken from the same station point. For details of Spherical Photogrammetry see (Fangi, 2,3,4,9. A particular procedure appropriate for the orientation of very narrow field of view lenses panorama has been already set up and used for the orientation and plotting of the three minarets of the Great Mosque of Omayyad’s in Damascus, Syria. Their heights range from 60 to 80 meters above the courtyard pavement of the mosque. The technique consists in taking different focal lengths panorama from the same station point (Fangi, New Castle, 2010, one with WA wide angle and another one with NA Narrow Angle, adding to the stability of WA panorama the resolution of NA panorama. The same approach has been used in the Sagrada Familia, for the survey of San Barnaba’s spire. In 1990 the A. made a survey of the same spire. But in comparison to the years 90, there is one difficulty more: now the rear of the spire is not visible because of the construction of the roof of the church, while it was visible in 1990. The solution has been then to use the original images taken in the years 90 for the rear of the spire and the spherical panoramas for the rest, i.e. the part toward the façade, using the original control points. Then we had to make a combined adjustment of non metric images using DLT approach and spherical photogrammetry algorithms. The restitution has been indeed carried out using both type of imagery, spherical panorama and non metric images. The results are satisfactory in the sense that

  7. Monte Carlo and experimental dosimetric study of the mHDR-v2 brachytherapy source

    Directory of Open Access Journals (Sweden)

    Chandola Rakesh

    2010-01-01

    Full Text Available The conventional treatment planning system (TPS gives analytical calculations with ± 15 to 20% dose, which may lead to over exposure of critical organs or under dose of target. It is to obtain dose distribution parameters of nucletron high dose rate (HDR microselectron v2 (mHDR-v2 192 Ir brachytherapy source by experiment and by calculated study using Monte Carlo (MC EGSnrc code, and to find the similarity between them, and with any past study. To validate data, another MC GEANT4 study done in this work on the same source is also presented. Different software of the computer e.g. paint, excel, etc are employed for preparation of figures and graphs. The measured study of the source was done using an in-air ionization chamber, water phantom, and measurement set-up, while the calculated study was done by modeling the set up of the measured study by using the MC EGSnrc and GEANT4. Mean and probability are used in calculation of average values, and calculation of the uncertainties in result and discussion. The measured and calculated values of dose rate constant, radial dose function, and 2D anisotropy function were found to be in agreement with each other as well as with published data. The results of this study can be used as input to TPS.

  8. Quality control of the breast cancer treatments on Hdr brachytherapy with TLD-100

    Energy Technology Data Exchange (ETDEWEB)

    Torres H, F. [Universidad de Cordoba, Materials and Applied Physics Group, 230002 Monteria, Cordoba (Colombia); De la Espriella V, N. [Universidad de Cordoba, Grupo Avanzado de Materiales y Sistemas Complejos, 230002 Monteria, Cordoba (Colombia); Sanchez C, A., E-mail: franciscotorreshoyos@yahoo.com [Universidad de Cordoba, Departamento de Enfermeria, 230002 Monteria, Cordoba (Colombia)

    2014-07-01

    An anthropomorphic Phantom, a female trunk, was built with a natural bone structure and experimental material coated, glycerin and water-based material called JJT to build soft tissue equivalent to the muscle of human tissue, and a polymer (styrofoam) to build the lung as critical organ to simulate the treatment of breast cancer, with high dose rate brachytherapy (Hdr) and sources of Ir-192. The treatments were planned and calculated for the critical organ: Lung, and injury of 2 cm in diameter in breast with Micro Selectron Hdr system and the software Plato Brachytherapy V 14.1 of the Nucletron (Netherlands) which uses the standard protocol of radiotherapy for brachytherapy treatments. The dose experimentally measured with dosimeters TLD-100 LiF: Mg; Ti, which were previously calibrated, were placed in the same positions and bodies mentioned above, with less than 5% uncertainty. The reading dosimeters was carried out in a Harshaw TLD 4500. The results obtained for calculated treatments, using the standard simulator, and the experimental with TLD-100, show a high concordance, as they are on average a ± 1.1% making process becomes in a quality control of this type of treatments. (Author)

  9. Artist's colour rendering of HDR scenes in 3D Mondrian colour-constancy experiments

    Science.gov (United States)

    Parraman, Carinna E.; McCann, John J.; Rizzi, Alessandro

    2010-01-01

    The presentation provides an update on ongoing research using three-dimensional Colour Mondrians. Two still life arrangements comprising hand-painted coloured blocks of 11 different colours were subjected to two different lighting conditions of a nearly uniform light and directed spotlights. The three-dimensional nature of these test targets adds shadows and multiple reflections, not found in flat Mondrian targets. Working from exactly the same pair of scenes, an author painted them using watercolour inks and paints to recreate both LDR and HDR Mondrians on paper. This provided us with a second set of appearance measurements of both scenes. Here we measured appearances by measuring reflectances of the artist's rendering. Land's Colour Mondrian extended colour constancy from a pixel to a complex scene. Since it used a planar array in uniform illumination, it did not measure the appearances of real life 3-D scenes in non-uniform illumination. The experiments in this paper, by simultaneously studying LDR and HDR renditions of the same array of reflectances, extend Land's Mondrian towards real scenes in non-uniform illumination. The results show that the appearances of many areas in complex scenes do not correlate with reflectance.

  10. Implementation of the technique of partial irradiation accelerated the breast with high doses (HDR) brachytherapy; Puesta en marcha de la tecnica de irradiacion parcial acelerada de la mama con braquterapia de alta tasa de dosis (HDR)

    Energy Technology Data Exchange (ETDEWEB)

    Molina Lopez, M. Y.; Pardo Perez, E.; Castro Novais, J.; Martinez Ortega, J.; Ruiz Maqueda, S.; Cerro Penalver, E. del

    2013-07-01

    The objective of this work is presents procedure carried out in our Centre for the implementation of the accelerated partial breast irradiation (APBI, accelerated partial-breast irradiation) with high-rate brachytherapy (HDR), using plastic tubes as applicators. Carried out measures, the evaluation of the dosimetric parameters analyzing and presenting the results. (Author)

  11. A study of optimization techniques in HDR brachytherapy for the prostate

    Science.gov (United States)

    Pokharel, Ghana Shyam

    Several studies carried out thus far are in favor of dose escalation to the prostate gland to have better local control of the disease. But optimal way of delivery of higher doses of radiation therapy to the prostate without hurting neighboring critical structures is still debatable. In this study, we proposed that real time high dose rate (HDR) brachytherapy with highly efficient and effective optimization could be an alternative means of precise delivery of such higher doses. This approach of delivery eliminates the critical issues such as treatment setup uncertainties and target localization as in external beam radiation therapy. Likewise, dosimetry in HDR brachytherapy is not influenced by organ edema and potential source migration as in permanent interstitial implants. Moreover, the recent report of radiobiological parameters further strengthen the argument of using hypofractionated HDR brachytherapy for the management of prostate cancer. Firstly, we studied the essential features and requirements of real time HDR brachytherapy treatment planning system. Automating catheter reconstruction with fast editing tools, fast yet accurate dose engine, robust and fast optimization and evaluation engine are some of the essential requirements for such procedures. Moreover, in most of the cases we performed, treatment plan optimization took significant amount of time of overall procedure. So, making treatment plan optimization automatic or semi-automatic with sufficient speed and accuracy was the goal of the remaining part of the project. Secondly, we studied the role of optimization function and constraints in overall quality of optimized plan. We have studied the gradient based deterministic algorithm with dose volume histogram (DVH) and more conventional variance based objective functions for optimization. In this optimization strategy, the relative weight of particular objective in aggregate objective function signifies its importance with respect to other objectives

  12. Dosimetric equivalence of nonstandard HDR brachytherapy catheter patterns

    Energy Technology Data Exchange (ETDEWEB)

    Cunha, J. A. M.; Hsu, I-C.; Pouliot, J. [University of California, San Francisco, California 94115 (United States)

    2009-01-15

    Purpose: To determine whether alternative high dose rate prostate brachytherapy catheter patterns can result in similar or improved dose distributions while providing better access and reducing trauma. Materials and Methods: Standard prostate cancer high dose rate brachytherapy uses a regular grid of parallel needle positions to guide the catheter insertion. This geometry does not easily allow the physician to avoid piercing the critical structures near the penile bulb nor does it provide position flexibility in the case of pubic arch interference. This study used CT datasets with 3 mm slice spacing from ten previously treated patients and digitized new catheters following three hypothetical catheter patterns: conical, bi-conical, and fireworks. The conical patterns were used to accommodate a robotic delivery using a single entry point. The bi-conical and fireworks patterns were specifically designed to avoid the critical structures near the penile bulb. For each catheter distribution, a plan was optimized with the inverse planning algorithm, IPSA, and compared with the plan used for treatment. Irrelevant of catheter geometry, a plan must fulfill the RTOG-0321 dose criteria for target dose coverage (V{sub 100}{sup Prostate}>90%) and organ-at-risk dose sparing (V{sub 75}{sup Bladder}<1 cc, V{sub 75}{sup Rectum}<1 cc, V{sub 125}{sup Urethra}<<1 cc). Results: The three nonstandard catheter patterns used 16 nonparallel, straight divergent catheters, with entry points in the perineum. Thirty plans from ten patients with prostate sizes ranging from 26 to 89 cc were optimized. All nonstandard patterns fulfilled the RTOG criteria when the clinical plan did. In some cases, the dose distribution was improved by better sparing the organs-at-risk. Conclusion: Alternative catheter patterns can provide the physician with additional ways to treat patients previously considered unsuited for brachytherapy treatment (pubic arch interference) and facilitate robotic guidance of

  13. Linear-array-based photoacoustic imaging of human microcirculation with a range of high frequency transducer probes.

    Science.gov (United States)

    Zafar, Haroon; Breathnach, Aedán; Subhash, Hrebesh M; Leahy, Martin J

    2015-05-01

    Photoacoustic imaging (PAI) with a linear-array-based probe can provide a convenient means of imaging the human microcirculation within its native structural context and adds functional information. PAI using a multielement linear transducer array combined with multichannel collecting system was used for in vivo volumetric imaging of the blood microcirculation, the total concentration of hemoglobin (HbT), and the hemoglobin oxygen saturation (sO₂) within human tissue. Three-dimensional (3-D) PA and ultrasound (US) volumetric scans were acquired from the forearm skin by linearly translating the transducer with a stepper motor over a region of interest, while capturing two-dimensional images using 15, 21, and 40 MHz frequency transducer probes. For the microvasculature imaging, PA images were acquired at 800- and 1064-nm wavelengths. For the HbT and sO₂ estimates, PA images were collected at 750- and 850-nm wavelengths. 3-D microcirculation, HbT, and sO₂ maps of the forearm skin were obtained from normal subjects. The linear-array-based PAI has been found promising in terms of resolution, imaging depth, and imaging speed for in vivo microcirculation imaging within human skin. We believe that a reflection type probe, similar to existing clinical US probes, is most likely to succeed in real clinical applications. Its advantages include ease of use, speed, and familiarity for radiographers and clinicians.

  14. Validation of a novel robot-assisted 3DUS system for real-time planning and guidance of breast interstitial HDR brachytherapy.

    Science.gov (United States)

    Poulin, Eric; Gardi, Lori; Barker, Kevin; Montreuil, Jacques; Fenster, Aaron; Beaulieu, Luc

    2015-12-01

    In current clinical practice, there is no integrated 3D ultrasound (3DUS) guidance system clinically available for breast brachytherapy. In this study, the authors present a novel robot-assisted 3DUS system for real-time planning and guidance of breast interstitial high dose rate (HDR) brachytherapy treatment. For this work, a new computer controlled robotic 3DUS system was built to perform a hybrid motion scan, which is a combination of a 6 cm linear translation with a 30° rotation at both ends. The new 3DUS scanner was designed to fit on a modified Kuske assembly, keeping the current template grid configuration but modifying the frame to allow the mounting of the 3DUS system at several positions. A finer grid was also tested. A user interface was developed to perform image reconstruction, semiautomatic segmentation of the surgical bed as well as catheter reconstruction and tracking. A 3D string phantom was used to validate the geometric accuracy of the reconstruction. The volumetric accuracy of the system was validated with phantoms using magnetic resonance imaging (MRI) and computed tomography (CT) images. In order to accurately determine whether 3DUS can effectively replace CT for treatment planning, the authors have compared the 3DUS catheter reconstruction to the one obtained from CT images. In addition, in agarose-based phantoms, an end-to-end procedure was performed by executing six independent complete procedures with both 14 and 16 catheters, and for both standard and finer Kuske grids. Finally, in phantoms, five end-to-end procedures were performed with the final CT planning for the validation of 3DUS preplanning. The 3DUS acquisition time is approximately 10 s. A paired Student t-test showed that there was no statistical significant difference between known and measured values of string separations in each direction. Both MRI and CT volume measurements were not statistically different from 3DUS volume (Student t-test: p > 0.05) and they were

  15. Implant strategies for endocervical and interstitial ultrasound hyperthermia adjunct to HDR brachytherapy for the treatment of cervical cancer

    Science.gov (United States)

    Wootton, Jeffery H.; Prakash, Punit; Hsu, I.-Chow Joe; Diederich, Chris J.

    2011-07-01

    Catheter-based ultrasound devices provide a method to deliver 3D conformable heating integrated with HDR brachytherapy delivery. Theoretical characterization of heating patterns was performed to identify implant strategies for these devices which can best be used to apply hyperthermia to cervical cancer. A constrained optimization-based hyperthermia treatment planning platform was used for the analysis. The proportion of tissue >=41 °C in a hyperthermia treatment volume was maximized with constraints Tmax 200 cm3) is possible using multiple sectored interstitial and endocervical ultrasound devices. The endocervical device can heat >41 °C to 4.6 cm diameter compared to 3.6 cm for the interstitial. Sectored applicators afford tight control of heating that is robust to perfusion changes in most regularly spaced configurations. T90 in example patient cases was 40.5-42.7 °C (1.9-39.6 EM43 °C) at 1 kg m-3 s-1 with 10/14 patients >=41 °C. Guidelines are presented for positioning of implant catheters during the initial surgery, selection of ultrasound applicator configurations, and tailored power schemes for achieving T90 >= 41 °C in clinically practical implant configurations. Catheter-based ultrasound devices, when adhering to the guidelines, show potential to generate conformal therapeutic heating ranging from a single endocervical device targeting small volumes local to the cervix (directional interstitial applicators in the lateral periphery to target much larger volumes (6 cm radial), while preferentially limiting heating of the bladder and rectum.

  16. Exploration of joint systems and major horizontal stress direction in HDR drillholes of the Soultz site (Alsace, France)

    Energy Technology Data Exchange (ETDEWEB)

    Genter, A. [BRGM/GIG, Orleans (France); Tenzer, H. [Stadtwerke Bad Urach (Germany)

    1997-12-01

    Borehole imaging logs enable continuous recording of natural and artificial planar discontinuities on the drillhole wall and data of the drillhole geometry to be made. Efforts were made to resolve the orientation and characterization of the natural joint system, the active fault pattern, the alteration zones, the orientation of microcracks and the direction of maximum horizontal stress. Intense logging operations and measurements were carried out in the HDR drillholes GPK1 and EPS1 between 1000 and 3600 m depth in the Muschelkalk, Bunter and Granite at Soultz sous Forets. With the help of investigations on subvertical fractures the orientation of the maximum horizontal stress direction was determined as N175 E{+-}17 . These results are consistent with previous investigations performed in the horeholes GPK-1 and EPS-1. (orig./AKF) [Deutsch] Bohrlochmessungen mit dem akustschen Borehole Televiewer und elektrischen Formation MicroScanner (Imager) sowie dem Azimuthal Resistivity Imager und verschiedenen Sonic-Sonden ermoeglichen eine kontinuierliche Aufnahme sowohl von natuerlichen und kuenstlich erzeugten planaren Diskontinuitaeten an der Bohrlochwand als auch der Bohrlochgeometrie. Es wurden die Orientierung und Charakterisierung des natuerlichen Kluftsystems, das aktive Stoerungsmuster, die Alterationszonen, die Orientierung von Mikrorissen und die Orientierung der maximalen horizontalen Hauptspannungsrichtung ermittelt. Die Verfuegbarkeit von Strukturdaten aus Bohrloechern durch Bohrlochmessungen und hydraulischen Testen ermoeglicht die Bestimmung von hydraulisch aktiven Klueften und deren Beziehung zum regionalen Spannungsfeld. Mit Hilfe spezieller Bohrloch-Logs wurden die Orientierung und Haeufigkeit planarer Diskontinuitaeten und ihre scheinbare Oeffnungsweite sowie die Vorzugsrichtung der verschiedenen scheinbaren Weiten bestimmt. Innerhalb des gemeinsamen europaeischen Hot-Dry-Rock-Geothermal-Forschungsprogramms wurden vielfaeltige Bohrlochmessungen in den

  17. Signal restoration method for restraining the range walk error of Geiger-mode avalanche photodiode lidar in acquiring a merged three-dimensional image.

    Science.gov (United States)

    Xu, Lu; Zhang, Yu; Zhang, Yong; Wu, Long; Yang, Chenghua; Yang, Xu; Zhang, Zijing; Zhao, Yuan

    2017-04-10

    The fluctuation in the number of signal photoelectrons will cause a range walk error in a Geiger-mode avalanche photodiode (Gm-APD) lidar, which significantly depends on the target intensity. For a nanosecond-pulsed laser, the range walk error of traditional time-of-flight will cause deterioration. A new signal restoration method, based on the Poisson probability response model and the center-of-mass algorithm, is proposed to restrain the range walk error. We obtain a high-precision depth and intensity merged 3D image using this method. The range accuracy is 0.6 cm, and the intensity error is less than 3%.

  18. Correction factors for source strength determination in HDR brachytherapy using the in-phantom method.

    Science.gov (United States)

    Ubrich, Frank; Wulff, Jörg; Engenhart-Cabillic, Rita; Zink, Klemens

    2014-05-01

    For the purpose of clinical source strength determination for HDR brachytherapy sources, the German society for Medical Physics (DGMP) recommends in their report 13 the usage of a solid state phantom (Krieger-phantom) with a thimble ionization chamber. In this work, the calibration chain for the determination of the reference air-kerma rate Ka,100 and reference dose rate to waterDw,1 by ionization chamber measurement in the Krieger-phantom was modeled via Monte Carlo simulations. These calculations were used to determine global correction factors k(tot), which allows a user to directly convert the reading of an ionization chamber calibrated in terms of absorbed dose to water, into the desired quantity Ka,100 or Dw,1. The factor k(tot) was determined for four available (192)Ir sources and one (60)Co source with three different thimble ionization chambers. Finally, ionization chamber measurements on three μSelectron V2 HDR sources within the Krieger-phantom were performed and Ka,100 was determined according to three different methods: 1) using a calibration factor in terms of absorbed dose to water with the global correction factor [Formula: see text] according DGMP 13 2) using a global correction factor calculated via Monte Carlo 3) using a direct reference air-kerma rate calibration factor determined by the national metrology institute PTB. The comparison of Monte Carlo based [Formula: see text] with those from DGMP 13 showed that the DGMP data were systematically smaller by about 2-2.5%. The experimentally determined [Formula: see text] , based on the direct Ka,100 calibration were also systematically smaller by about 1.5%. Despite of these systematical deviations, the agreement of the different methods was in almost all cases within the 1σ level of confidence of the interval of their respective uncertainties in a Gaussian distribution. The application of Monte Carlo based [Formula: see text] for the determination of Ka,100 for three μSelectron V2 sources

  19. SU-F-T-13: Transit Dose Comparisons for Co-60 and Ir-192 HDR Sources

    Energy Technology Data Exchange (ETDEWEB)

    Gimenez-Alventosa, V; Ballester, F [University of Valencia, Burjassot (Spain); Vijande, J [University of Valencia and IFIC(CSIC-UV), Burjassot (Spain); Perez-Calatayud, J [Hospital Clinica Benidorm, Benidorm, and Hospital Universitari i Politecnic La Fe, Valencia (Spain)

    2016-06-15

    Purpose: The purpose of this study is to compare the transit dose due to the movement of high dose rate (HDR) Ir-192 and Co-60 sources along the transfer tube. This is performed by evaluating air-kerma differences in the vicinity of the transfer tube when both sources are moved with the same velocity from a HDR brachytherapy afterloader into a patient. Methods: Monte Carlo simulations have been performed using PENELOPE2014. mHDR-v2 and Flexisource sources have been considered. Collisional kerma has been scored. The sources were simulated within a plastic catheter located in an infinite air phantom. The movement of the seed was included by displacing their positions along the connecting catheter from z=−75 cm to z=+75 cm and combining them. Backscatter from the afterloader and the patient was not considered. Since modern afterloaders like Flexitron (Elekta) or Saginova (Bebig) are able to use equally Ir-192 and Co-60 sources it was assumed that both sources are displaced with equal speed. Typical content activity values were provided by the manufacturer (460 GBq for Ir-192 and 75 GBq for Co-60). Results: 2D distributions were obtained with type-A uncertainties (k=2) less than 0.01%. From those, the air kerma ratio Co-60/Ir-192 was evaluated weighted by their corresponding activities. It was found that it varies slowly with distance (less than 10% variation) but strongly in time due to the shorter half-life of the Ir-192 (73.83 days). The maximum ratio is located close to the catheter with a value of 0.57 when both sources are installed by the manufacturer, while increasing up to 1.25 at the end of the recommended working life (90 days) of the Ir-192 source. Conclusion: Air-kerma ratios are almost constant (0.51–0.57) in the vicinity of the source. Nevertheless, air-kerma ratios increase rapidly whenever the Ir-192 is approaching the end of its life.

  20. Determination of mean ionization potential using magnetic resonance imaging for the reduction of proton beam range uncertainties: theory and application

    Science.gov (United States)

    Sudhyadhom, Atchar

    2017-11-01

    The accurate determination of mean ionization potential (I m) has the potential to reduce range uncertainty based margins and therefore allow for more focal treatments in proton radiotherapy. Many methods have been proposed to reduce uncertainty in I m and stopping power ratios (SPR), each with varying degrees of accuracy and issues. In this work, we present a simple parameterized model to determine I m in human biological tissue, allowing for the computation of patient-specific I m at the voxel level using magnetic resonance imaging (MRI). The model requires the measurement of three parameters by MRI, with only two parameters, mass percent water content and mass percent hydrogen content in organic molecules, required for the special case of soft tissues. The accuracy of this I m determination method was evaluated in available ‘standard’ (ICRU Report #44, (ICRU 1989 Tissue Substitutes in Radiation Dosimetry and Measurement (Bethesda, MD: International Commission on Radiation Units and Measurements))) human tissues. The sensitivity of this I m determination method to in vivo perturbations was also tested by calculating the effect of 10% variations in the experimentally measurable parameters on I m and SPR. For the human tissues modeled in this work, a high level of accuracy with low susceptibility to perturbations in measurement error was achieved in the prediction of I m. Root-mean-square errors in I m were within 0.77% and 1.8% for both soft and bony tissues, and were 0.09% and 0.2% for the SPR of soft and bony tissues, respectively, assuming knowledge of electron density. Proof of principle MR measurements and model-based computations of I m and SPR were taken in phantom for a series of hydrogenous solutions and compared against expected I m and SPR calculations from known elemental composition. MR determined I m and SPR values in a known composition solution were determined to within 5% and 0.52%, respectively. We present a novel model to accurately

  1. Photometric and Colorimeric Comparison of HDR and Spctrally Resolved Rendering Images

    DEFF Research Database (Denmark)

    Amdemeskel, Mekbib Wubishet; Soreze, Thierry Silvio Claude; Thorseth, Anders

    2017-01-01

    . The spectral irradiances of the light source were measured for two lighting scenarios: low and high correlated colour temperature (CCT) white lighting conditions for the modelling of the light source. Based on these measurements, we have conducted spectrally resolved renderings with a spectral renderer, Ocean...

  2. Three-Dimensional ISAR Imaging Method for High-Speed Targets in Short-Range Using Impulse Radar Based on SIMO Array

    OpenAIRE

    Zhou, Xinpeng; Wei, Guohua; Wu, Siliang; Wang, Dawei

    2016-01-01

    This paper proposes a three-dimensional inverse synthetic aperture radar (ISAR) imaging method for high-speed targets in short-range using an impulse radar. According to the requirements for high-speed target measurement in short-range, this paper establishes the single-input multiple-output (SIMO) antenna array, and further proposes a missile motion parameter estimation method based on impulse radar. By analyzing the motion geometry relationship of the warhead scattering center after transla...

  3. HDR Brachytherapy in the Management of High-Risk Prostate Cancer

    Science.gov (United States)

    Masson, Susan; Persad, Raj; Bahl, Amit

    2012-01-01

    High-dose-rate (HDR) brachytherapy is used with increasing frequency for the treatment of prostate cancer. It is a technique which allows delivery of large individual fractions to the prostate without exposing adjacent normal tissues to unacceptable toxicity. This approach is particularly favourable in prostate cancer where tumours are highly sensitive to dose escalation and to increases in radiotherapy fraction size, due to the unique radiobiological behaviour of prostate cancers in contrast with other malignancies. In this paper we discuss the rationale and the increasing body of clinical evidence for the use of this technique in patients with high-risk prostate cancer, where it is combined with external beam radiotherapy. We highlight practical aspects of delivering treatment and discuss toxicity and limitations, with particular reference to current practice in the United Kingdom. PMID:22461791

  4. HDR Brachytherapy in the Management of High-Risk Prostate Cancer

    Directory of Open Access Journals (Sweden)

    Susan Masson

    2012-01-01

    Full Text Available High-dose-rate (HDR brachytherapy is used with increasing frequency for the treatment of prostate cancer. It is a technique which allows delivery of large individual fractions to the prostate without exposing adjacent normal tissues to unacceptable toxicity. This approach is particularly favourable in prostate cancer where tumours are highly sensitive to dose escalation and to increases in radiotherapy fraction size, due to the unique radiobiological behaviour of prostate cancers in contrast with other malignancies. In this paper we discuss the rationale and the increasing body of clinical evidence for the use of this technique in patients with high-risk prostate cancer, where it is combined with external beam radiotherapy. We highlight practical aspects of delivering treatment and discuss toxicity and limitations, with particular reference to current practice in the United Kingdom.

  5. Mixed integer programming improves comprehensibility and plan quality in inverse optimization of prostate HDR-brachytherapy

    CERN Document Server

    Gorissen, Bram L; Hoffmann, Aswin L

    2014-01-01

    Current inverse treatment planning methods that optimize both catheter positions and dwell times in prostate HDR brachytherapy use surrogate linear or quadratic objective functions that have no direct interpretation in terms of dose-volume histogram (DVH) criteria, do not result in an optimum or have long solution times. We decrease the solution time of existing linear and quadratic dose-based programming models (LP and QP, respectively) to allow optimizing over potential catheter positions using mixed integer programming. An additional average speed-up of 75% can be obtained by stopping the solver at an early stage, without deterioration of the plan quality. For a fixed catheter configuration, the dwell time optimization model LP solves to optimality in less than 15 seconds, which confirms earlier results. We propose an iterative procedure for QP that allows to prescribe the target dose as an interval, while retaining independence between the solution time and the number of dose calculation points. This iter...

  6. Long-range and depth-selective imaging of macroscopic targets using low-coherence and wide-field interferometry (Conference Presentation)

    Science.gov (United States)

    Woo, Sungsoo; Kang, Sungsam; Yoon, Changhyeong; Choi, Wonshik

    2016-03-01

    With the advancement of 3D display technology, 3D imaging of macroscopic objects has drawn much attention as they provide the contents to display. The most widely used imaging methods include a depth camera, which measures time of flight for the depth discrimination, and various structured illumination techniques. However, these existing methods have poor depth resolution, which makes imaging complicated structures a difficult task. In order to resolve this issue, we propose an imaging system based upon low-coherence interferometry and off-axis digital holographic imaging. By using light source with coherence length of 200 micro, we achieved the depth resolution of 100 micro. In order to map the macroscopic objects with this high axial resolution, we installed a pair of prisms in the reference beam path for the long-range scanning of the optical path length. Specifically, one prism was fixed in position, and the other prism was mounted on a translation stage and translated in parallel to the first prism. Due to the multiple internal reflections between the two prisms, the overall path length was elongated by a factor of 50. In this way, we could cover a depth range more than 1 meter. In addition, we employed multiple speckle illuminations and incoherent averaging of the acquired holographic images for reducing the specular reflections from the target surface. Using this newly developed system, we performed imaging targets with multiple different layers and demonstrated imaging targets hidden behind the scattering layers. The method was also applied to imaging targets located around the corner.

  7. On the use of HDR 60Co source with the MammoSite radiation therapy system.

    Science.gov (United States)

    Baltas, D; Lymperopoulou, G; Zamboglou, N

    2008-12-01

    This work summarizes Monte Carlo results in order to evaluate the potential of using HDR 60Co sources in accelerated partial breast irradiation (APBI) with the MammoSite applicator. Simulations have been performed using the MCNP5 Monte Carlo Code, in simple geometries comprised of two concentric spheres; the internal consisting of selected concentrations, C, of a radiographic contrast solution in water (Omnipaque 300) to simulate the MammoSite balloon and the external consisting of water to simulate surrounding tissue. The magnitude of the perturbation of delivered dose due to the radiographic contrast medium used in the MammoSite applicator is calculated. At the very close vicinity of the balloon surface, a dose build-up region is observed, which leads to a dose overestimation by the treatment planning system (TPS) which depends on Omnipaque 300 solution concentration (and is in order of 2.3%, 3.0%, and 4.5%, respectively, at 1 mm away from the balloon - water interface, for C=10%, 15%, and 20%). However, dose overestimation by the TPS is minimal for points lying at the prescription distance (d=1 cm) or beyond, for all simulated concentrations and radii of MammoSite balloon. An analytical estimation of the integral dose outside the CTV in the simple geometries simulated shows that dose to the breast for MammoSite applications is expected to be comparable using HDR 60Co and 192Ir sources, and higher than that for 169Yb. The higher enegies of 60Co sources result to approximately twice radiation protection requirements as compared to 169Ir sources. However, they allow for more accurate dosimetry calculation with currently used treatment planning algorithms for 60Co sources, compared to 169Ir.

  8. Ir-192 HDR transit dose and radial dose function determination using alanine/EPR dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Calcina, Carmen S Guzman [Departamento de FIsica e Matematica, FFCLRP, Universidade de Sao Paulo, Av Bandeirantes 3900, 14040-901, Ribeirao Preto, SP (Brazil); Almeida, Adelaide de [Departamento de FIsica e Matematica, FFCLRP, Universidade de Sao Paulo, Av Bandeirantes 3900, 14040-901, Ribeirao Preto, SP (Brazil); Rocha, Jose R Oliveira [Setor de FIsica Medica-CEB-UNICAMP e Setor de Radioterapia-CAISM-UNICAMP (Brazil); Abrego, Felipe Chen [Departamento de FIsica e Matematica, FFCLRP, Universidade de Sao Paulo, Av Bandeirantes 3900, 14040-901, Ribeirao Preto, SP (Brazil); Baffa, Oswaldo [Departamento de FIsica e Matematica, FFCLRP, Universidade de Sao Paulo, Av Bandeirantes 3900, 14040-901, Ribeirao Preto, SP (Brazil)

    2005-03-21

    Source positioning close to the tumour in high dose rate (HDR) brachytherapy is not instantaneous. An increment of dose will be delivered during the movement of the source in the trajectory to its static position. This increment is the transit dose, often not taken into account in brachytherapeutic treatment planning. The transit dose depends on the prescribed dose, number of treatment fractions, velocity and activity of the source. Combining all these factors, the transit dose can be 5% higher than the prescribed absorbed dose value (Sang-Hyun and Muller-Runkel, 1994 Phys. Med. Biol. 39 1181-8, Nath et al 1995 Med. Phys. 22 209-34). However, it cannot exceed this percentage (Nath et al 1995). In this work, we use the alanine-EPR (electron paramagnetic resonance) dosimetric system using analysis of the first derivative of the signal. The transit dose was evaluated for an HDR system and is consistent with that already presented for TLD dosimeters (Bastin et al 1993 Int. J. Radiat. Oncol. Biol. Phys. 26 695-702). Also using the same dosimetric system, the radial dose function, used to evaluate the geometric dose degradation around the source, was determined and its behaviour agrees better with those obtained by Monte Carlo simulations (Nath et al 1995, Williamson and Nath 1991 Med. Phys. 18 434-48, Ballester et al 1997 Med. Phys. 24 1221-8, Ballester et al 2001 Phys. Med. Biol. 46 N79-90) than with TLD measurements (Nath et al 1990 Med. Phys. 17 1032-40)

  9. Virtual HDR CyberKnife SBRT for Localized Prostatic Carcinoma: 5-year Disease-free Survival and Toxicity Observations

    Directory of Open Access Journals (Sweden)

    Donald Blake Fuller

    2014-11-01

    Full Text Available PURPOSEProstate stereotactic body radiotherapy (SBRT may substantially recapitulate the dose distribution of high-dose-rate (HDR brachytherapy, representing an externally delivered Virtual HDR treatment method. Herein we present 5-year outcomes from a cohort of consecutively treated Virtual HDR SBRT prostate cancer patients.METHODSSeventy-nine patients were treated from 2006 - 2009, 40 low-risk and 39 intermediate-risk, under IRB-approved clinical trial, to 38 Gy in 4 fractions. The planning target volume (PTV included prostate plus a 2-mm volume expansion in all directions, with selective use of a 5-mm prostate-to-PTV expansion and proximal seminal vesicle coverage in intermediate-risk patients, to better cover potential extraprostatic disease; rectal PTV margin reduced to zero in all cases. The prescription dose covered > 95% of the PTV (V100 >= 95%, with a minimum 150% PTV dose escalation to create HDR-like PTV dose distribution.RESULTSMedian pre-SBRT PSA level of 5.6 ng/mL decreased to 0.05 ng/mL 5 years out and 0.02 ng/mL 6 years out. At least one PSA bounce was seen in 55 patients (70% but only 3 of them subsequently relapsed, Biochemical-relapse-free survival was 100% and 92% for low-risk and intermediate-risk patients, respectively, by ASTRO definition (98% and 92% by Phoenix definition. Local relapse did not occur, distant metastasis-free survival was 100% and 95% by risk-group, and disease-specific survival was 100%. Acute and late grade 2 GU toxicity incidence was 10% and 9%, respectively; with 6% late grade 3 GU toxicity. Acute urinary retention did not occur. Acute and late grade 2 GI toxicity was 0% and 1%, respectively, with no grade 3 or higher toxicity. Of patients potent pre-SBRT, 65% remained so at 5 years.CONCLUSIONSVirtual HDR prostate SBRT creates a very low PSA nadir, a high rate of 5-year disease-free survival and an acceptable toxicity incidence, with results closely resembling those reported post-HDR brachytherapy.

  10. [HDR 192Ir brachytherapy in treatment of basal cell carcinoma of the lower eyelid and inner angle - our experience].

    Science.gov (United States)

    Furdová, A; Lukačko, P; Lederleitner, D

    2013-06-01

    First experience and evaluation of relapses in group of patients after surgery with applied adjuvant HDR brachytherapy for recurrent tumor after incomplete excision of basal cell carcinoma of the lower eyelid and inner angle. Patients with recurrent basal cell carcinoma of the lower eyelid in year 2010. In 3 male patients with recurrent finding of basal cell after surgery we applied adjuvant HDR 192Ir brachytherapy. The isodose curve chosen to prescribe the dose was 5 mm away from the skin surface. In the year 2010 we applied adjuvant HDR 192Ir brachytherapy in 3 male patients with recurrent basal cell carcinoma. The average age was 58 years (52 to 75 years). From group of 41 patients with non melanotic malignant tumors of the eyelids in 3 patients (7.3 %) with relapse after incomplete excision of the basal cell carcinoma of the lower eyelid we applied after removal of stitches after surgery adjuvant HDR 192Ir brachytherapy. For each patient was made individual orfit mask that bore plastic applicators. Tungsten eye shield applicator was applied to protect the eye globe. Treatment of 10 fractions of 4.5 Gy single dose (5 times weekly) were scheduled within 2 weeks. Patients received outpatient treatment. Acute toxicity postradiation erythema of eyelid and skin around relieved by standard symptomatic treatment within a few days after completion of radiation therapy. In 2 year interval after HDR 192Ir brachytherapy we did not record the occurrence of late complications such as corneal ulcers. Our preliminary experience shows excellent early skin tolerance. After 2 years of follow-up at 6 month interval we did not recognize relapse in our group of patients. The proposed technique of HDR 192Ir brachytherapy after surgery should be considered a new clinical treatment in patients with recurrent non melanotic eyelid cancer. Its main advantage lies in the usefulness in all types of basal cell and squamous cell carcinoma and sebaceous carcinoma of the eyelids, without

  11. Visual Comfort Analysis of Innovative Interior and Exterior Shading Systems for Commercial Buildings using High Resolution Luminance Images

    Energy Technology Data Exchange (ETDEWEB)

    Konis, Kyle; Lee, Eleanor; Clear, Robert

    2011-01-11

    The objective of this study was to explore how calibrated high dynamic range (HDR) images (luminance maps) acquired in real world daylit environments can be used to characterize, evaluate, and compare visual comfort conditions of innovative facade shading and light-redirecting systems. Detailed (1536 x 1536 pixel) luminance maps were time-lapse acquired from two view positions in an unoccupied full scale testbed facility. These maps were analyzed using existing visual comfort metrics to quantify how innovative interior and exterior shading systems compare to conventional systems under real sun and sky conditions over a solstice-to-solstice test interval. The results provide a case study in the challenges and potential of methods of visualizing, evaluating and summarizing daily and seasonal variation of visual comfort conditions computed from large sets of image data.

  12. Development of a low-energy x-ray camera for the imaging of secondary electron bremsstrahlung x-ray emitted during proton irradiation for range estimation

    Science.gov (United States)

    Ando, Koki; Yamaguchi, Mitsutaka; Yamamoto, Seiichi; Toshito, Toshiyuki; Kawachi, Naoki

    2017-06-01

    Imaging of secondary electron bremsstrahlung x-ray emitted during proton irradiation is a possible method for measurement of the proton beam distribution in phantom. However, it is not clear that the method is used for range estimation of protons. For this purpose, we developed a low-energy x-ray camera and conducted imaging of the bremsstrahlung x-ray produced during irradiation of proton beams. We used a 20 mm  ×  20 mm  ×  1 mm finely grooved GAGG scintillator that was optically coupled to a one-inch square high quantum efficiency (HQE)-type position-sensitive photomultiplier tube to form an imaging detector. The imaging detector was encased in a 2 cm-thick tungsten container, and a pinhole collimator was attached to its camera head. After performance of the camera was evaluated, secondary electron bremsstrahlung x-ray imaging was conducted during irradiation of the proton beams for three different proton energies, and the results were compared with Monte Carlo simulation as well as calculated value. The system spatial resolution and sensitivity of the developed x-ray camera with 1.5 mm-diameter pinhole collimator were estimated to be 32 mm FWHM and 5.2  ×  10-7 for ~35 keV x-ray photons at 100 cm from the collimator surface, respectively. We could image the proton beam tracks by measuring the secondary electron bremsstrahlung x-ray during irradiation of the proton beams, and the ranges for different proton energies could be estimated from the images. The measured ranges from the images were well matched with the Monte Carlo simulation, and slightly smaller than the calculated values. We confirmed that the imaging of the secondary electron bremsstrahlung x-ray emitted during proton irradiation with the developed x-ray camera has the potential to be a new tool for proton range estimations.

  13. Quality assessment of images displayed on LCD screen with local backlight dimming

    DEFF Research Database (Denmark)

    Mantel, Claire; Burini, Nino; Korhonen, Jari

    2013-01-01

    This paper presents a subjective experiment collecting quality assessment of images displayed on a LCD with local backlight dimming using two methodologies: absolute category ratings and paired-comparison. Some well-known objective quality metrics are then applied to the stimuli...... and their respective performance are analyzed. The HDR-VDP metric seems to achieve good performance on every source image....

  14. NOAA TIFF Image - 4m Bathymetric Depth Range of Red Snapper Research Areas in the South Atlantic Bight, 2010

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This dataset contains unified Bathymetric Depth Range GeoTiffs with 4x4 meter cell resolution describing the topography of 15 areas along the shelf edge off the...

  15. SU-D-BRA-04: Computerized Framework for Marker-Less Localization of Anatomical Feature Points in Range Images Based On Differential Geometry Features for Image-Guided Radiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Soufi, M; Arimura, H; Toyofuku, F [Kyushu University, Fukuoka, Fukuoka (Japan); Nakamura, K [Hamamatsu University School of Medicine, Hamamatsu, Shizuoka (Japan); Hirose, T; Umezu, Y [Kyushu University Hospital, Fukuoka, Fukuoka (Japan); Shioyama, Y [Saga Heavy Ion Medical Accelerator in Tosu, Tosu, Saga (Japan)

    2016-06-15

    Purpose: To propose a computerized framework for localization of anatomical feature points on the patient surface in infrared-ray based range images by using differential geometry (curvature) features. Methods: The general concept was to reconstruct the patient surface by using a mathematical modeling technique for the computation of differential geometry features that characterize the local shapes of the patient surfaces. A region of interest (ROI) was firstly extracted based on a template matching technique applied on amplitude (grayscale) images. The extracted ROI was preprocessed for reducing temporal and spatial noises by using Kalman and bilateral filters, respectively. Next, a smooth patient surface was reconstructed by using a non-uniform rational basis spline (NURBS) model. Finally, differential geometry features, i.e. the shape index and curvedness features were computed for localizing the anatomical feature points. The proposed framework was trained for optimizing shape index and curvedness thresholds and tested on range images of an anthropomorphic head phantom. The range images were acquired by an infrared ray-based time-of-flight (TOF) camera. The localization accuracy was evaluated by measuring the mean of minimum Euclidean distances (MMED) between reference (ground truth) points and the feature points localized by the proposed framework. The evaluation was performed for points localized on convex regions (e.g. apex of nose) and concave regions (e.g. nasofacial sulcus). Results: The proposed framework has localized anatomical feature points on convex and concave anatomical landmarks with MMEDs of 1.91±0.50 mm and 3.70±0.92 mm, respectively. A statistically significant difference was obtained between the feature points on the convex and concave regions (P<0.001). Conclusion: Our study has shown the feasibility of differential geometry features for localization of anatomical feature points on the patient surface in range images. The proposed

  16. W-Band Polarimetric Scattering Features of a Tactical Ground Target Using a 1.56THz 3D Imaging Compact Range

    Science.gov (United States)

    2001-01-01

    differences in the amplitudes of scatterers (due primarily to elevation related phasing and aperture dependent pixel division) the PSMs of the TSAR images...on a T8OB with the TSAR data is shown in Figure 2. Figure 2a is an image made by projecting the 3D data onto a top view of the target. Figure 2b is...an TSAR data set taken at thesame angle. The TSAR measurements were made in a separate 1.56THz compact range where the model target is fully

  17. Imaging of prompt gamma rays emitted during delivery of clinical proton beams with a Compton camera: feasibility studies for range verification.

    Science.gov (United States)

    Polf, Jerimy C; Avery, Stephen; Mackin, Dennis S; Beddar, Sam

    2015-09-21

    The purpose of this paper is to evaluate the ability of a prototype Compton camera (CC) to measure prompt gamma rays (PG) emitted during delivery of clinical proton pencil beams for prompt gamma imaging (PGI) as a means of providing in vivo verification of the delivered proton radiotherapy beams. A water phantom was irradiated with clinical 114 MeV and 150 MeV proton pencil beams. Up to 500 cGy of dose was delivered per irradiation using clinical beam currents. The prototype CC was placed 15 cm from the beam central axis and PGs from 0.2 MeV up to 6.5 MeV were measured during irradiation. From the measured data (2D) images of the PG emission were reconstructed. (1D) profiles were extracted from the PG images and compared to measured depth dose curves of the delivered proton pencil beams. The CC was able to measure PG emission during delivery of both 114 MeV and 150 MeV proton beams at clinical beam currents. 2D images of the PG emission were reconstructed for single 150 MeV proton pencil beams as well as for a 5   ×   5 cm mono-energetic layer of 114 MeV pencil beams. Shifts in the Bragg peak (BP) range were detectable on the 2D images. 1D profiles extracted from the PG images show that the distal falloff of the PG emission profile lined up well with the distal BP falloff. Shifts as small as 3 mm in the beam range could be detected from the 1D PG profiles with an accuracy of 1.5 mm or better. However, with the current CC prototype, a dose of 400 cGy was required to acquire adequate PG signal for 2D PG image reconstruction. It was possible to measure PG interactions with our prototype CC during delivery of proton pencil beams at clinical dose rates. Images of the PG emission could be reconstructed and shifts in the BP range were detectable. Therefore PGI with a CC for in vivo range verification during proton treatment delivery is feasible. However, improvements in the prototype CC detection efficiency and reconstruction algorithms are necessary

  18. Thermal dosimetry analysis combined with patient-specific thermal modeling of clinical interstitial ultrasound hyperthermia integrated within HDR brachytherapy for treatment of locally advanced prostate cancer

    Science.gov (United States)

    Salgaonkar, Vasant A.; Wootton, Jeff; Prakash, Punit; Scott, Serena; Hsu, I. C.; Diederich, Chris J.

    2017-03-01

    This study presents thermal dosimetry analysis from clinical treatments where ultrasound hyperthermia (HT) was administered following high-dose rate (HDR) brachytherapy treatment for locally advanced prostate cancer as part of a clinical pilot study. HT was administered using ultrasound applicators from within multiple 13-g brachytherapy catheters implanted along the posterior periphery of the prostate. The heating applicators were linear arrays of sectored tubular transducers (˜7 MHz), with independently powered array elements enabling energy deposition with 3D spatial control. Typical heat treatments employed time-averaged peak acoustic intensities of 1 - 3 W/cm2 and lasted for 60 - 70 minutes. Throughout the treatments, temperatures at multiple points were monitored using multi-junction thermocouples, placed within available brachytherapy catheters throughout mid-gland prostate and identified as the hyperthermia target volume (HTV). Clinical constraints allowed placement of 8 - 12 thermocouple sensors in the HTV and patient-specific 3D thermal modeling based on finite element methods (FEM) was used to supplement limited thermometry. Patient anatomy, heating device positions, orientations, and thermometry junction locations were obtained from patient CT scans and HDR and hyperthermia planning software. The numerical models utilized the applied power levels recorded during the treatments. Tissue properties such as perfusion and acoustic absorption were varied within physiological ranges such that squared-errors between measured and simulated temperatures were minimized. This data-fitting was utilized for 6 HT treatments to estimate volumetric temperature distributions achieved in the HTV and surrounding anatomy devoid of thermocouples. For these treatments, the measured and simulated T50 values in the hyperthermia target volume (HTV) were between 40.1 - 43.9 °C and 40.3 - 44.9 °C, respectively. Maximum temperatures between 46.8 - 49.8 °C were measured during

  19. Clinical implementation and failure mode and effects analysis of HDR skin brachytherapy using Valencia and Leipzig surface applicators.

    Science.gov (United States)

    Sayler, Elaine; Eldredge-Hindy, Harriet; Dinome, Jessie; Lockamy, Virginia; Harrison, Amy S

    2015-01-01

    The planning procedure for Valencia and Leipzig surface applicators (VLSAs) (Nucletron, Veenendaal, The Netherlands) differs substantially from CT-based planning; the unfamiliarity could lead to significant errors. This study applies failure modes and effects analysis (FMEA) to high-dose-rate (HDR) skin brachytherapy using VLSAs to ensure safety and quality. A multidisciplinary team created a protocol for HDR VLSA skin treatments and applied FMEA. Failure modes were identified and scored by severity, occurrence, and detectability. The clinical procedure was then revised to address high-scoring process nodes. Several key components were added to the protocol to minimize risk probability numbers. (1) Diagnosis, prescription, applicator selection, and setup are reviewed at weekly quality assurance rounds. Peer review reduces the likelihood of an inappropriate treatment regime. (2) A template for HDR skin treatments was established in the clinic's electronic medical record system to standardize treatment instructions. This reduces the chances of miscommunication between the physician and planner as well as increases the detectability of an error. (3) A screen check was implemented during the second check to increase detectability of an error. (4) To reduce error probability, the treatment plan worksheet was designed to display plan parameters in a format visually similar to the treatment console display, facilitating data entry and verification. (5) VLSAs are color coded and labeled to match the electronic medical record prescriptions, simplifying in-room selection and verification. Multidisciplinary planning and FMEA increased detectability and reduced error probability during VLSA HDR brachytherapy. This clinical model may be useful to institutions implementing similar procedures. Copyright © 2015 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.

  20. SU-G-TeP1-01: A Simulation Study to Investigate Maximum Allowable Deformations of Implant Geometry Before Plan Objectives Are Violated in Prostate HDR Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Babier, A [Department of Physics, Engineering Physics and Astronomy, Queens University, Kingston, Ontario (Canada); Joshi, C [Department of Physics, Engineering Physics and Astronomy, Queens University, Kingston, Ontario (Canada); Cancer Center of Southeastern Ontario, Kingston General Hospital, Kingston, Ontario (Canada)

    2016-06-15

    Purpose: In prostate HDR brachytherapy dose distributions are highly sensitive to changes in prostate volume and catheter displacements. We investigate the maximum deformations in implant geometry before planning objectives are violated. Methods: A typical prostate Ir-192 HDR brachytherapy reference plan was calculated on the Oncentra planning system, which used CT images from a tissue equivalent prostate phantom (CIRS Model 053S) embedded inside a pelvis wax phantom. The prostate was deformed and catheters were displaced in simulations using a code written in MATLAB. For each deformation dose distributions were calculated, based on TG43 methods, using the MATLAB code. The calculations were validated through comparison with Oncentra calculations for the reference plan, and agreed within 0.12%SD and 0.3%SD for dose and volume, respectively. Isotropic prostate volume deformations of up to +34% to −27% relative to its original volume, and longitudinal catheter displacements of 7.5 mm in superior and inferior directions were simulated. Planning objectives were based on American Brachytherapy Society guidelines for prostate and urethra volumes. A plan violated the planning objectives when less than 90% of the prostate volume received the prescribed dose or higher (V{sub 100}), or the urethral volume receiving 125% of prescribed dose or higher was more than 1 cc (U{sub 125}). Lastly, the dose homogeneity index (DHI=1-V{sub 150}/V{sub 100}) was evaluated; a plan was considered sub-optimal when the DHI fell below 0.62. Results and Conclusion: Planning objectives were violated when the prostate expanded by 10.7±0.5% or contracted by 11.0±0.2%; objectives were also violated when catheters were displaced by 4.15±0.15 mm and 3.70±0.15 mm in the superior and inferior directions, respectively. The DHI changes did not affect the plan optimality, except in the case of prostate compression. In general, catheter displacements have a significantly larger impact on plan

  1. A Feasibility Study of Fricke Dosimetry as an Absorbed Dose to Water Standard for 192Ir HDR Sources

    Science.gov (United States)

    deAlmeida, Carlos Eduardo; Ochoa, Ricardo; de Lima, Marilene Coelho; David, Mariano Gazineu; Pires, Evandro Jesus; Peixoto, José Guilherme; Salata, Camila; Bernal, Mario Antônio

    2014-01-01

    High dose rate brachytherapy (HDR) using 192Ir sources is well accepted as an important treatment option and thus requires an accurate dosimetry standard. However, a dosimetry standard for the direct measurement of the absolute dose to water for this particular source type is currently not available. An improved standard for the absorbed dose to water based on Fricke dosimetry of HDR 192Ir brachytherapy sources is presented in this study. The main goal of this paper is to demonstrate the potential usefulness of the Fricke dosimetry technique for the standardization of the quantity absorbed dose to water for 192Ir sources. A molded, double-walled, spherical vessel for water containing the Fricke solution was constructed based on the Fricke system. The authors measured the absorbed dose to water and compared it with the doses calculated using the AAPM TG-43 report. The overall combined uncertainty associated with the measurements using Fricke dosimetry was 1.4% for k = 1, which is better than the uncertainties reported in previous studies. These results are promising; hence, the use of Fricke dosimetry to measure the absorbed dose to water as a standard for HDR 192Ir may be possible in the future. PMID:25521914

  2. 2D and 3D flash laser imaging for long-range surveillance in maritime border security: detection and identification for counter UAS applications

    Science.gov (United States)

    Hespel, L.; Riviere, N.; Fraces, M.; Dupouy, P. E.; Coyac, A.; Barillot, P.; Fauquex, S.; Plyer, A.; Tauvy, M.; Jacquart, M.; Vin, I.; Nascimben, E.; Perez, C.; Velayguet, J. P.; Gorce, D.

    2017-05-01

    To address the issues of maritime border surveillance or long range UAV identification, we develop two laser imagers (a 2D and a 3D system) with long range (LR) capacities to improve significantly the performances in terms of scope of monitoring and persistence of functions (e.g. H24, degraded visibility...). These systems are based on a new generation of focal plane arrays (FPA) with Avalanche PhotoDiode (APD) and are combined with high-performance image processing ("real-time") devoted to superresolution or tracking. In this paper, we first present the results of several maritime surveillance or Counter- Unmanned Aircraft System (C-UAS) demonstrations respectively conducted on a coastal site and a sensitive area. Comparisons between passive and active sensors are shown. The measurements obtained on various maritime targets are completed by end to end modelling in order to assess the systems performances in various atmospheric environments.

  3. WE-EF-303-03: A New Aperture-Based Imaging System for Prompt-Gamma Range Verification of Proton Beam Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Ready, J; Pak, R [UC Berkeley, Berkeley, CA (United States); Mihailescu, L [Lawrence Berkeley National Laboratory, Berkeley, CA (United States); Vetter, K [UC Berkeley, Berkeley, CA (United States); Lawrence Berkeley National Laboratory, Berkeley, CA (United States)

    2015-06-15

    Purpose: To develop and characterize a novel aperture-based imaging system for high-energy gamma-rays. This collimated system will provide 2-dimensional imaging capability for verification of proton beam range and Bragg peak dose via prompt-gamma detection. Methods: A multi-knife-edge slit collimator has been designed, constructed, and characterized via simulations and experimental measurements. The 20×20×7.5 cm{sup 3} tungsten collimator and accompanying LSO scintillation detector were simulated using the TOPAS Geant4 -based Monte Carlo package. Iterative reconstruction methods were combined with point response functions to characterize the imaging performance of the system. The response of the system has begun to be characterized experimentally as well, using 2.6 MeV gamma-rays from Th-228. Results: Both simulation and experimental results indicate that this collimated system provides 2-D imaging capability in the energy range of interest for prompt-gamma dose verification. In the current configuration, with collimator to source distance of 13 cm, image reconstruction of point sources resulted in spatial resolution (FWHM) of approximately 4 mm in both x-and y-directions in the imaging plane. The accuracy of positioning the point sources is less than 1 mm. Conclusion: This work has characterized, via simulation and measurements, a novel multi-knife-edge slit collimator in front of a more conventional position-sensitive LSO scintillator detector. The multi-slit pattern is designed to increase detection efficiency and provide spatial information in 2-dimensions -- an improvement over a single-slit collimator design. The thickness and density of the collimator will allow this detection system to perform well in an environment with high gamma flux, while ultimately providing peak determination accuracy on the order of 1 mm. This material is based upon work supported by the Department of Energy National Nuclear Security Administration under Award Number: DE-NA0000979

  4. Imaging and autocorrelation of ultrafast infrared laser pulses in the 3-11-mum range with silicon CCD cameras and photodiodes.

    Science.gov (United States)

    Briggman, K A; Richter, L J; Stephenson, J C

    2001-02-15

    Standard silicon photodiodes and CCD cameras are convenient and inexpensive alternatives to cryogenically cooled diodes or arrays for autocorrelation and imaging of ultrafast IR laser pulses in the wavelength range 3-11 mum . The response of these Si devices to IR pulses of duration ~100 fs is proportional to E(n) , where E is the pulse energy and n is approximately the Si electronic bandgap divided by the photon energy.

  5. Influence of temporal noise on the skin blood flow measurements performed by cooled thermal imaging camera: limit possibilities within each physiological frequency range

    Science.gov (United States)

    Sagaidachnyi, A. A.; Volkov, I. U.; Fomin, A. V.

    2016-04-01

    This paper describes limit possibilities of modern cooled thermal imaging cameras as a tool for estimation of blood flow oscillations at the surface of living body. Skin temperature oscillations, as we assumed, are a consequence of the blood flow oscillations. We considered the temperature sensitivity 0.01-0.02 °C as a typical for the most of modern cooled long wave thermal imaging cameras. Fourier filter used to investigate the temperature signal separately within endothelial, neurogenic, myogenic, respiratory and cardiac frequency ranges. The level of temporal noise has been estimated during measurements of no living body with stabilized temperature ~ 24°C. The level of temperature oscillations has been calculated for the group of healthy subjects within each frequency range. Thus, we were able to determine signal-to-noise ratio within frequency band [0.001, 1] Hz. As a result, we determine that skin temperature oscillations measured by thermal imaging camera with sensitivity 0.02°C have the upper frequency limit ~ 0.2 Hz. In other words, within the respiratory and cardiac frequency ranges of blood flow oscillations the noise level exceeds signal one, and temperature measurements at the skin surface are practically useless. The endothelial, neurogenic and myogenic components of the temperature oscillations contain ~98% of the total spectral power of the signal. We have plot the empirical extrapolated curve of sensitivity of thermal imaging camera vs. frequency of the temperature oscillations. The data analysis shows that measurements of skin temperature oscillations within respiratory and cardiac ranges require the temperature sensitivity at least ~ 0.01°C and 0.001°C, respectively.

  6. Fast, automatic, and accurate catheter reconstruction in HDR brachytherapy using an electromagnetic 3D tracking system

    Energy Technology Data Exchange (ETDEWEB)

    Poulin, Eric; Racine, Emmanuel; Beaulieu, Luc, E-mail: Luc.Beaulieu@phy.ulaval.ca [Département de physique, de génie physique et d’optique et Centre de recherche sur le cancer de l’Université Laval, Université Laval, Québec, Québec G1V 0A6, Canada and Département de radio-oncologie et Axe Oncologie du Centre de recherche du CHU de Québec, CHU de Québec, 11 Côte du Palais, Québec, Québec G1R 2J6 (Canada); Binnekamp, Dirk [Integrated Clinical Solutions and Marketing, Philips Healthcare, Veenpluis 4-6, Best 5680 DA (Netherlands)

    2015-03-15

    Purpose: In high dose rate brachytherapy (HDR-B), current catheter reconstruction protocols are relatively slow and error prone. The purpose of this technical note is to evaluate the accuracy and the robustness of an electromagnetic (EM) tracking system for automated and real-time catheter reconstruction. Methods: For this preclinical study, a total of ten catheters were inserted in gelatin phantoms with different trajectories. Catheters were reconstructed using a 18G biopsy needle, used as an EM stylet and equipped with a miniaturized sensor, and the second generation Aurora{sup ®} Planar Field Generator from Northern Digital Inc. The Aurora EM system provides position and orientation value with precisions of 0.7 mm and 0.2°, respectively. Phantoms were also scanned using a μCT (GE Healthcare) and Philips Big Bore clinical computed tomography (CT) system with a spatial resolution of 89 μm and 2 mm, respectively. Reconstructions using the EM stylet were compared to μCT and CT. To assess the robustness of the EM reconstruction, five catheters were reconstructed twice and compared. Results: Reconstruction time for one catheter was 10 s, leading to a total reconstruction time inferior to 3 min for a typical 17-catheter implant. When compared to the μCT, the mean EM tip identification error was 0.69 ± 0.29 mm while the CT error was 1.08 ± 0.67 mm. The mean 3D distance error was found to be 0.66 ± 0.33 mm and 1.08 ± 0.72 mm for the EM and CT, respectively. EM 3D catheter trajectories were found to be more accurate. A maximum difference of less than 0.6 mm was found between successive EM reconstructions. Conclusions: The EM reconstruction was found to be more accurate and precise than the conventional methods used for catheter reconstruction in HDR-B. This approach can be applied to any type of catheters and applicators.

  7. A multicenter study to quantify systematic variations and associated uncertainties in source positioning with commonly used HDR afterloaders and ring applicators for the treatment of cervical carcinomas

    Energy Technology Data Exchange (ETDEWEB)

    Awunor, O., E-mail: onuora.awunor@stees.nhs.uk [The Medical Physics Department, The James Cook University Hospital, Marton Road, Middlesbrough TS4 3BW, England (United Kingdom); Berger, D. [Department of Radiotherapy, General Hospital of Vienna, Vienna A-1090 (Austria); Kirisits, C. [Department of Radiotherapy, Comprehensive Cancer Center, Medical University of Vienna, Vienna A-1090 (Austria)

    2015-08-15

    Purpose: The reconstruction of radiation source position in the treatment planning system is a key part of the applicator reconstruction process in high dose rate (HDR) brachytherapy treatment of cervical carcinomas. The steep dose gradients, of as much as 12%/mm, associated with typical cervix treatments emphasize the importance of accurate and precise determination of source positions. However, a variety of methodologies with a range in associated measurement uncertainties, of up to ±2.5 mm, are currently employed by various centers to do this. In addition, a recent pilot study by Awunor et al. [“Direct reconstruction and associated uncertainties of {sup 192}Ir source dwell positions in ring applicators using gafchromic film in the treatment planning of HDR brachytherapy cervix patients,” Phys. Med. Biol. 58, 3207–3225 (2013)] reported source positional differences of up to 2.6 mm between ring sets of the same type and geometry. This suggests a need for a comprehensive study to assess and quantify systematic source position variations between commonly used ring applicators and HDR afterloaders across multiple centers. Methods: Eighty-six rings from 20 European brachytherapy centers were audited in the form of a postal audit with each center collecting the data independently. The data were collected by setting up the rings using a bespoke jig and irradiating gafchromic films at predetermined dwell positions using four afterloader types, MicroSelectron, Flexitron, GammaMed, and MultiSource, from three manufacturers, Nucletron, Varian, and Eckert & Ziegler BEBIG. Five different ring types in six sizes (Ø25–Ø35 mm) and two angles (45° and 60°) were used. Coordinates of irradiated positions relative to the ring center were determined and collated, and source position differences quantified by ring type, size, and angle. Results: The mean expanded measurement uncertainty (k = 2) along the direction of source travel was ±1.4 mm. The standard deviation

  8. A compact wide-range spectrometer with image intensifier: unexpected advantages, new functions, and a variety of applications.

    Science.gov (United States)

    Protopopov, Vladimir

    2012-05-01

    Gated intensified spectrometers are very efficient instruments not only in time-resolved applications but also in all other fields were traditional non-gated and non-intensified devices are so popular today. This paper describes the design and performance of a simple, reliable, and relatively inexpensive wide-range gated intensified spectrometer that was conceived as a prototype for volume production. With 200-900 nm spectral range, 3 ns temporal resolution, variable optical gain up to 4000, repetition rate up to 200 kHz, spectral resolution 2 nm (0.9 nm with deconvolution), and affordable price, such a device may be useful for budget research laboratories working in the fields of cell biology, laser-induced breakdown spectroscopy, molecular kinetics, plasma diagnostics, materials characterization, combustion analysis, and forensic analysis.

  9. A multicentre audit of HDR/PDR brachytherapy absolute dosimetry in association with the INTERLACE trial (NCT015662405)

    Science.gov (United States)

    Díez, P.; Aird, E. G. A.; Sander, T.; Gouldstone, C. A.; Sharpe, P. H. G.; Lee, C. D.; Lowe, G.; Thomas, R. A. S.; Simnor, T.; Bownes, P.; Bidmead, M.; Gandon, L.; Eaton, D.; Palmer, A. L.

    2017-12-01

    A UK multicentre audit to evaluate HDR and PDR brachytherapy has been performed using alanine absolute dosimetry. This is the first national UK audit performing an absolute dose measurement at a clinically relevant distance (20 mm) from the source. It was performed in both INTERLACE (a phase III multicentre trial in cervical cancer) and non-INTERLACE brachytherapy centres treating gynaecological tumours. Forty-seven UK centres (including the National Physical Laboratory) were visited. A simulated line source was generated within each centre’s treatment planning system and dwell times calculated to deliver 10 Gy at 20 mm from the midpoint of the central dwell (representative of Point A of the Manchester system). The line source was delivered in a water-equivalent plastic phantom (Barts Solid Water) encased in blocks of PMMA (polymethyl methacrylate) and charge measured with an ion chamber at 3 positions (120° apart, 20 mm from the source). Absorbed dose was then measured with alanine at the same positions and averaged to reduce source positional uncertainties. Charge was also measured at 50 mm from the source (representative of Point B of the Manchester system). Source types included 46 HDR and PDR 192Ir sources, (7 Flexisource, 24 mHDR-v2, 12 GammaMed HDR Plus, 2 GammaMed PDR Plus, 1 VS2000) and 1 HDR 60Co source, (Co0.A86). Alanine measurements when compared to the centres’ calculated dose showed a mean difference (±SD) of  +1.1% (±1.4%) at 20 mm. Differences were also observed between source types and dose calculation algorithm. Ion chamber measurements demonstrated significant discrepancies between the three holes mainly due to positional variation of the source within the catheter (0.4%–4.9% maximum difference between two holes). This comprehensive audit of absolute dose to water from a simulated line source showed all centres could deliver the prescribed dose to within 5% maximum difference between measurement and calculation.

  10. Catheter-based ultrasound hyperthermia with HDR brachytherapy for treatment of locally advanced cancer of the prostate and cervix

    Science.gov (United States)

    Diederich, Chris J.; Wootton, Jeff; Prakash, Punit; Salgaonkar, Vasant; Juang, Titania; Scott, Serena; Chen, Xin; Cunha, Adam; Pouliot, Jean; Hsu, I. C.

    2011-03-01

    A clinical treatment delivery platform has been developed and is being evaluated in a clinical pilot study for providing 3D controlled hyperthermia with catheter-based ultrasound applicators in conjunction with high dose rate (HDR) brachytherapy. Catheter-based ultrasound applicators are capable of 3D spatial control of heating in both angle and length of the devices, with enhanced radial penetration of heating compared to other hyperthermia technologies. Interstitial and endocavity ultrasound devices have been developed specifically for applying hyperthermia within HDR brachytherapy implants during radiation therapy in the treatment of cervix and prostate. A pilot study of the combination of catheter based ultrasound with HDR brachytherapy for locally advanced prostate and cervical cancer has been initiated, and preliminary results of the performance and heating distributions are reported herein. The treatment delivery platform consists of a 32 channel RF amplifier and a 48 channel thermocouple monitoring system. Controlling software can monitor and regulate frequency and power to each transducer section as required during the procedure. Interstitial applicators consist of multiple transducer sections of 2-4 cm length × 180 deg and 3-4 cm × 360 deg. heating patterns to be inserted in specific placed 13g implant catheters. The endocavity device, designed to be inserted within a 6 mm OD plastic tandem catheter within the cervix, consists of 2-3 transducers × dual 180 or 360 deg sectors. 3D temperature based treatment planning and optimization is dovetailed to the HDR optimization based planning to best configure and position the applicators within the catheters, and to determine optimal base power levels to each transducer section. To date we have treated eight cervix implants and six prostate implants. 100 % of treatments achieved a goal of >60 min duration, with therapeutic temperatures achieved in all cases. Thermal dosimetry within the hyperthermia target

  11. MO-FG-CAMPUS-JeP1-01: Prompt Gamma Imaging with a Multi-Knife-Edge Slit Collimator: Evaluation for Use in Proton Beam Range Verification

    Energy Technology Data Exchange (ETDEWEB)

    Ready, J [UC Berkeley, Berkeley, CA (United States); Negut, V; Mihailescu, L [Lawrence Berkeley National Laboratory, Berkeley, CA (United States); Vetter, K [UC Berkeley, Berkeley, CA (United States); Lawrence Berkeley National Laboratory, Berkeley, CA (United States)

    2016-06-15

    Purpose: To evaluate and characterize a multi-slit collimated imaging system for use in prompt gamma range verification of proton therapy. Methods: Acrylic (PMMA) targets were irradiated with a 50 MeV proton beam. With the collimator placed 13 cm from the beam axis, photons of energy from 2–7 MeV were measured. Image reconstruction provided 2-dimensional distribution of gamma rays. Estimated Bragg peak location was compared with 1-dimensional profiles of photon images. Shifts in Bragg peak were simulated by physically moving the targets in 1 mm increments. Results: The imaging system measured prompt gamma emissions resulting from a 50 MeV proton beam, at currents up to 2 nA, incident on a PMMA target. Overall system detection efficiency was approximately 2.6×10{sup −5} gamma/proton. With delivery of 1×10{sup 11} protons, shifts of 1 mm in the target location were detected in 2D prompt gamma images and 1D profiles. With delivery of 1×10{sup 8} protons, shifts of approximately 3 mm were detectable. Conclusion: This work has characterized the performance of a prototype multi-slit collimated imaging system. The system can produce 2D images of prompt gamma distributions and detect shifts in Bragg peak location down to 1 mm. These results encourage further development and optimization of the system for clinical proton beam applications. This material is based upon work supported by the Department of Energy National Nuclear Security Administration under Award Number: DENA0000979 through the Nuclear Science and Security Consortium.

  12. Varying-energy CT imaging method based on EM-TV

    Science.gov (United States)

    Chen, Ping; Han, Yan

    2016-11-01

    For complicated structural components with wide x-ray attenuation ranges, conventional fixed-energy computed tomography (CT) imaging cannot obtain all the structural information. This limitation results in a shortage of CT information because the effective thickness of the components along the direction of x-ray penetration exceeds the limit of the dynamic range of the x-ray imaging system. To address this problem, a varying-energy x-ray CT imaging method is proposed. In this new method, the tube voltage is adjusted several times with the fixed lesser interval. Next, the fusion of grey consistency and logarithm demodulation are applied to obtain full and lower noise projection with a high dynamic range (HDR). In addition, for the noise suppression problem of the analytical method, EM-TV (expectation maximization-total Jvariation) iteration reconstruction is used. In the process of iteration, the reconstruction result obtained at one x-ray energy is used as the initial condition of the next iteration. An accompanying experiment demonstrates that this EM-TV reconstruction can also extend the dynamic range of x-ray imaging systems and provide a higher reconstruction quality relative to the fusion reconstruction method.

  13. Analog Encoding Voltage—A Key to Ultra-Wide Dynamic Range and Low Power CMOS Image Sensor

    Directory of Open Access Journals (Sweden)

    Orly Yadid-Pecht

    2013-03-01

    Full Text Available Usually Wide Dynamic Range (WDR sensors that autonomously adjust their integration time to fit intra-scene illumination levels use a separate digital memory unit. This memory contains the data needed for the dynamic range. Motivated by the demands for low power and chip area reduction, we propose a different implementation of the aforementioned WDR algorithm by replacing the external digital memory with an analog in-pixel memory. This memory holds the effective integration time represented by analog encoding voltage (AEV. In addition, we present a “ranging” scheme of configuring the pixel integration time in which the effective integration time is configured at the first half of the frame. This enables a substantial simplification of the pixel control during the rest of the frame and thus allows for a significantly more remarkable DR extension. Furthermore, we present the implementation of “ranging” and AEV concepts on two different designs, which are targeted to reach five and eight decades of DR, respectively. We describe in detail the operation of both systems and provide the post-layout simulation results for the second solution. The simulations show that the second design reaches DR up to 170 dBs. We also provide a comparative analysis in terms of the number of operations per pixel required by our solution and by other widespread WDR algorithms. Based on the calculated results, we conclude that the proposed two designs, using “ranging” and AEV concepts, are attractive, since they obtain a wide dynamic range at high operation speed and low power consumption.

  14. Image-guided high-dose-rate interstitial brachytherapy – a valuable salvage treatment approach for loco-regional recurrence of papillary thyroid cancer

    Directory of Open Access Journals (Sweden)

    Ning Wu

    2016-04-01

    Full Text Available Purpose : To report the treatment effect of image-guided high-dose-rate (HDR interstitial brachytherapy for refractory recurrence of papillary thyroid cancer (PTC. Case report: This 66-year-old female presented with recurrence 5 years after thyroidectomy for PTC. Despite external irradiation and radioactive 131I, the lesion expanded as 3.7 × 3.0 × 2.3 cm3 and 2.0 × 1.5 × 1.5 cm3. The locoregional recurrent tumor was treated with image-guided HDR interstitial brachytherapy. The total dose of 30 Gy in 6 fractions were delivered on the whole recurrent tumor. Results: Removal of the recurrent tumor was securely achieved by HDR interstitial brachytherapy guided with ultrasound, computed tomography (CT, and magnetic resonance imaging (MRI scanning. The refractory tumor in the patients healed uneventfully after HDR interstitial brachytherapy without recurrence during the 14 months of follow-up. Conclusions : The image-guided HDR interstitial brachytherapy may be a valuable salvage treatment approach for refractory recurrence of PTC.

  15. Monte Carlo characterization of the Gamma-Med Hdr plus Ir-192 brachytherapy source

    Energy Technology Data Exchange (ETDEWEB)

    Reyes, E.; Sosa, M. A.; Gil V, A. [Universidad de Guanajuato, Division de Ciencias e Ingenierias, Av. Insurgentes 2354, 37150 Leon, Guanajuato (Mexico); Monzon, E., E-mail: eric_1985@fisica.ugto.mx [IMSS, Unidad Medica de Alta Especialidad No. 1, Av. Adolfo Lopez Mateos 1813, 37340 Leon, Guanajuato (Mexico)

    2015-10-15

    Full text: The MCNP4C Monte Carlo code was used to simulate the dosimetry around the Gamma-Med Hdr Plus iridium-192 brachytherapy source in both air/vacuum and water environments. Dosimetry data in water was calculated and are presented into an away-along table. All dosimetric quantities recommended by the AAPM Task Group 43 report have been also calculated. These quantities are air kerma strength, dose rate constant, radial dose function and anisotropy function. The obtained data are compared to this source reference data, finding results in good agreement with them. In this study, recommendations of the AAPM TG-43U1 report have been followed and comply with the most recent AAPM and ESTRO physics committee recommendations about Monte Carlo techniques. The data in the present study complement published data and can be used as input in the Tps or as benchmark data to verify the results of the treatment planning systems as well as a means of comparison with other datasets from this source. (Author)

  16. Observing and characterizing avalanche activity in the Khumbu Himal, Nepal, using Pleiades and airborne HDR imagery

    Science.gov (United States)

    Thompson, Sarah; Nicholson, Lindsey; Klug, Christoph; Rieg, Lorenzo; Sailer, Rudolf; Bucher, Tilman; Brauchle, Jörg

    2017-04-01

    In the high, steep terrain of the Khumbu Himal, Nepal, snow avalanches play an important role in glacier mass balance, and rockfall supplies much of the rock material that forms the extensive debris covers on glaciers in the region. Information on the frequency and size of gravitational mass movements is helpful for understanding current and future glacier behaviour but currently lacking. In this study we use a combination of high resolution Pleiades optical satellite imagery in conjunction with airborne HDR imagery of slopes in deep shadow or overexposed snow slopes, provided by the German Aerospace Center (DLR) MACS system (see Brauchle et al., MM3.2/GI2.12/GMPV6.4/HS11.13/NH8.9/SSS12.24), to undertake a qualitative observational study of the gravitational processes evident in these sets of imagery. We classify the features found and discuss their likely frequency in the context of previously published research findings. Terrain analysis based upon digital terrain models derived from the same Pleiades imagery is used to investigate the slope angle, degree of confinement, curvature and aspect of observed avalanche and rock fall tracks. This work presents a first overview of the types of gravitational slides affecting glaciers of the Khumbu Himal. Subsequent research efforts will focus on attempting to quantify volumes of mass movement using repeat satellite imagery.

  17. Real-time verification of HDR brachytherapy source location: implementation of detector redundancy

    Science.gov (United States)

    Nakano, T.; Suchowerska, N.; McKenzie, D. R.; Bilek, M. M.

    2005-01-01

    Independent treatment verification for high dose rate (HDR) brachytherapy is needed to ensure that the treatment proceeds as prescribed. In this paper, we investigate the feasibility of a proposed real-time source position verification process. This process provides immediate confirmation of the source position during the treatment, so that the treatment can be aborted and modified if necessary. We show that an array of dosimeters placed on the patient's skin can independently verify the position in three dimensions. This verification was demonstrated by using a diamond detector placed in several locations on the surface of an anthropomorphic phantom. A mathematical algorithm was constructed to estimate the location of the source given a measured data set in the presence of tissue heterogeneity. The accuracy of the source localization was found to increase with the number of detectors used to compute the estimation of the source position. The resolution to which the 12 detectors can identify the location of the source was within 3 mm.

  18. Commissioning and quality assurance procedures for the HDR Valencia skin applicators

    Directory of Open Access Journals (Sweden)

    Domingo Granero

    2016-11-01

    Full Text Available The Valencia applicators (Nucletron, an Elekta company, Elekta AB, Stockholm, Sweden are cup-shaped tungsten applicators with a flattening filter used to collimate the radiation produced by a high-dose-rate (HDR 192 Ir source, and provide a homogeneous absorbed dose at a given depth. This beam quality provides a good option for the treatment of skin lesions at shallow depth (3-4 mm. The user must perform commissioning and periodic testing of these applicators to guarantee the proper and safe delivery of the intended absorbed dose, as recommended in the standards in radiation oncology. In this study, based on AAPM and GEC-ESTRO guidelines for brachytherapy units and our experience, a set of tests for the commissioning and periodic testing of the Valencia applicators is proposed. These include general considerations, verification of the manufacturer documentation and physical integrity, evaluation of the source-to-indexer distance and reproducibility, setting the library plan in the treatment planning system, evaluation of flatness and symmetry, absolute output and percentage depth dose verification, independent calculation of the treatment time, and visual inspection of the applicator before each treatment. For each test, the proposed methodology, equipment, frequency, expected results, and tolerance levels (when applicable are provided.

  19. DOCUMENTING A COMPLEX MODERN HERITAGE BUILDING USING MULTI IMAGE CLOSE RANGE PHOTOGRAMMETRY AND 3D LASER SCANNED POINT CLOUDS

    Directory of Open Access Journals (Sweden)

    M. L. Vianna Baptista

    2013-07-01

    Full Text Available Integrating different technologies and expertises help fill gaps when optimizing documentation of complex buildings. Described below is the process used in the first part of a restoration project, the architectural survey of Theatre Guaira Cultural Centre in Curitiba, Brazil. To diminish time on fieldwork, the two-person-field-survey team had to juggle, during three days, the continuous artistic activities and performers’ intense schedule. Both technologies (high definition laser scanning and close-range photogrammetry were used to record all details in the least amount of time without disturbing the artists' rehearsals and performances. Laser Scanning was ideal to record the monumental stage structure with all of its existing platforms, light fixtures, scenery walls and curtains. Although scanned with high-definition, parts of the exterior façades were also recorded using Close Range Photogrammetry. Tiny cracks on the marble plaques and mosaic tiles, not visible in the point clouds, were then able to be precisely documented in order to create the exterior façades textures and damages mapping drawings. The combination of technologies and the expertise of service providers, knowing how and what to document, and what to deliver to the client, enabled maximum benefits to the following restoration project.

  20. Documenting a Complex Modern Heritage Building Using Multi Image Close Range Photogrammetry and 3d Laser Scanned Point Clouds

    Science.gov (United States)

    Vianna Baptista, M. L.

    2013-07-01

    Integrating different technologies and expertises help fill gaps when optimizing documentation of complex buildings. Described below is the process used in the first part of a restoration project, the architectural survey of Theatre Guaira Cultural Centre in Curitiba, Brazil. To diminish time on fieldwork, the two-person-field-survey team had to juggle, during three days, the continuous artistic activities and performers' intense schedule. Both technologies (high definition laser scanning and close-range photogrammetry) were used to record all details in the least amount of time without disturbing the artists' rehearsals and performances. Laser Scanning was ideal to record the monumental stage structure with all of its existing platforms, light fixtures, scenery walls and curtains. Although scanned with high-definition, parts of the exterior façades were also recorded using Close Range Photogrammetry. Tiny cracks on the marble plaques and mosaic tiles, not visible in the point clouds, were then able to be precisely documented in order to create the exterior façades textures and damages mapping drawings. The combination of technologies and the expertise of service providers, knowing how and what to document, and what to deliver to the client, enabled maximum benefits to the following restoration project.

  1. Short-range test of the universality of gravitational constant G at the millimeter scale using a digital image sensor

    Science.gov (United States)

    Ninomiya, K.; Akiyama, T.; Hata, M.; Hatori, M.; Iguri, T.; Ikeda, Y.; Inaba, S.; Kawamura, H.; Kishi, R.; Murakami, H.; Nakaya, Y.; Nishio, H.; Ogawa, N.; Onishi, J.; Saiba, S.; Sakuta, T.; Tanaka, S.; Tanuma, R.; Totsuka, Y.; Tsutsui, R.; Watanabe, K.; Murata, J.

    2017-09-01

    The composition dependence of gravitational constant G is measured at the millimeter scale to test the weak equivalence principle, which may be violated at short range through new Yukawa interactions such as the dilaton exchange force. A torsion balance on a turning table with two identical tungsten targets surrounded by two different attractor materials (copper and aluminum) is used to measure gravitational torque by means of digital measurements of a position sensor. Values of the ratios \\tilde{G}_Al-W/\\tilde{G}_Cu-W -1 and \\tilde{G}_Cu-W/GN -1 were (0.9 +/- 1.1sta +/- 4.8sys) × 10-2 and (0.2 +/- 0.9sta +/- 2.1sys) × 10-2 , respectively; these were obtained at a center to center separation of 1.7 cm and surface to surface separation of 4.5 mm between target and attractor, which is consistent with the universality of G. A weak equivalence principle (WEP) violation parameter of η_Al-Cu(r∼ 1 cm)=(0.9 +/- 1.1sta +/- 4.9sys) × 10-2 at the shortest range of around 1 cm was also obtained.

  2. Validation of a novel robot-assisted 3DUS system for real-time planning and guidance of breast interstitial HDR brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Poulin, Eric; Beaulieu, Luc, E-mail: Luc.Beaulieu@phy.ulaval.ca [Département de Physique, de Génie Physique et d’optique et Centre de Recherche sur le Cancer de l’Université Laval, Université Laval, Québec, Québec G1V 0A6, Canada and Département de Radio-oncologie et Axe Oncologie du Centre de Recherche du CHU de Québec, CHU de Québec, 11 Côte du Palais, Québec, Québec G1R 2J6 (Canada); Gardi, Lori; Barker, Kevin; Montreuil, Jacques; Fenster, Aaron [Imaging Research Laboratories, Robarts Research Institute, 100 Perth Drive, London, Ontario N6A 5K8 (Canada)

    2015-12-15

    Purpose: In current clinical practice, there is no integrated 3D ultrasound (3DUS) guidance system clinically available for breast brachytherapy. In this study, the authors present a novel robot-assisted 3DUS system for real-time planning and guidance of breast interstitial high dose rate (HDR) brachytherapy treatment. Methods: For this work, a new computer controlled robotic 3DUS system was built to perform a hybrid motion scan, which is a combination of a 6 cm linear translation with a 30° rotation at both ends. The new 3DUS scanner was designed to fit on a modified Kuske assembly, keeping the current template grid configuration but modifying the frame to allow the mounting of the 3DUS system at several positions. A finer grid was also tested. A user interface was developed to perform image reconstruction, semiautomatic segmentation of the surgical bed as well as catheter reconstruction and tracking. A 3D string phantom was used to validate the geometric accuracy of the reconstruction. The volumetric accuracy of the system was validated with phantoms using magnetic resonance imaging (MRI) and computed tomography (CT) images. In order to accurately determine whether 3DUS can effectively replace CT for treatment planning, the authors have compared the 3DUS catheter reconstruction to the one obtained from CT images. In addition, in agarose-based phantoms, an end-to-end procedure was performed by executing six independent complete procedures with both 14 and 16 catheters, and for both standard and finer Kuske grids. Finally, in phantoms, five end-to-end procedures were performed with the final CT planning for the validation of 3DUS preplanning. Results: The 3DUS acquisition time is approximately 10 s. A paired Student t-test showed that there was no statistical significant difference between known and measured values of string separations in each direction. Both MRI and CT volume measurements were not statistically different from 3DUS volume (Student t-test: p > 0

  3. Long-range compaction and flexibility of interphase chromatin in budding yeast analyzed by high-resolution imaging techniques

    Science.gov (United States)

    Bystricky, Kerstin; Heun, Patrick; Gehlen, Lutz; Langowski, Jörg; Gasser, Susan M.

    2004-11-01

    Little is known about how chromatin folds in its native state. Using optimized in situ hybridization and live imaging techniques have determined compaction ratios and fiber flexibility for interphase chromatin in budding yeast. Unlike previous studies, ours examines nonrepetitive chromatin at intervals short enough to be meaningful for yeast chromosomes and functional domains in higher eukaryotes. We reconcile high-resolution fluorescence in situ hybridization data from intervals of 14-100 kb along single chromatids with measurements of whole chromosome arms (122-623 kb in length), monitored in intact cells through the targeted binding of bacterial repressors fused to GFP derivatives. The results are interpreted with a flexible polymer model and suggest that interphase chromatin exists in a compact higher-order conformation with a persistence length of 170-220 nm and a mass density of 110-150 bp/nm. These values are equivalent to 7-10 nucleosomes per 11-nm turn within a 30-nm-like fiber structure. Comparison of long and short chromatid arm measurements demonstrates that chromatin fiber extension is also influenced by nuclear geometry. The observation of this surprisingly compact chromatin structure for transcriptionally competent chromatin in living yeast cells suggests that the passage of RNA polymerase II requires a very transient unfolding of higher-order chromatin structure. higher-order structure | 30-nm fiber | nucleosomes

  4. Imaging the nanomolar range of nitric oxide with an amplifier-coupled fluorescent indicator in living cells

    Science.gov (United States)

    Sato, Moritoshi; Hida, Naoki; Umezawa, Yoshio

    2005-10-01

    Nitric oxide (NO) is a small uncharged free radical that is involved in diverse physiological and pathophysiological mechanisms. NO is generated by three isoforms of NO synthase, endothelial, neuronal, and inducible ones. When generated in vascular endothelial cells, NO plays a key role in vascular tone regulation, in particular. Here, we describe an amplifier-coupled fluorescent indicator for NO to visualize physiological nanomolar dynamics of NO in living cells (detection limit of 0.1 nM). This genetically encoded high-sensitive indicator revealed that 1 nM of NO, which is enough to relax blood vessels, is generated in vascular endothelial cells even in the absence of shear stress. The nanomolar range of basal endothelial NO thus revealed appears to be fundamental to vascular homeostasis. fluorescence resonance energy transfer | genetic encoding

  5. Storm Identification, Tracking and Forecasting Using High-Resolution Images of Short-Range X-Band Radar

    Directory of Open Access Journals (Sweden)

    Sajid Shah

    2015-05-01

    Full Text Available Rain nowcasting is an essential part of weather monitoring. It plays a vital role in human life, ranging from advanced warning systems to scheduling open air events and tourism. A nowcasting system can be divided into three fundamental steps, i.e., storm identification, tracking and nowcasting. The main contribution of this work is to propose procedures for each step of the rain nowcasting tool and to objectively evaluate the performances of every step, focusing on two-dimension data collected from short-range X-band radars installed in different parts of Italy. This work presents the solution of previously unsolved problems in storm identification: first, the selection of suitable thresholds for storm identification; second, the isolation of false merger (loosely-connected storms; and third, the identification of a high reflectivity sub-storm within a large storm. The storm tracking step of the existing tools, such as TITANand SCIT, use only up to two storm attributes, i.e., center of mass and area. It is possible to use more attributes for tracking. Furthermore, the contribution of each attribute in storm tracking is yet to be investigated. This paper presents a novel procedure called SALdEdA (structure, amplitude, location, eccentricity difference and areal difference for storm tracking. This work also presents the contribution of each component of SALdEdA in storm tracking. The second order exponential smoothing strategy is used for storm nowcasting, where the growth and decay of each variable of interest is considered to be linear. We evaluated the major steps of our method. The adopted techniques for automatic threshold calculation are assessed with a 97% goodness. False merger and sub-storms within a cluster of storms are successfully handled. Furthermore, the storm tracking procedure produced good results with an accuracy of 99.34% for convective events and 100% for stratiform events.

  6. Pixel multiplexing technique for real-time three-dimensional-imaging laser detection and ranging system using four linear-mode avalanche photodiodes

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Fan; Wang, Yuanqing, E-mail: yqwang@nju.edu.cn; Li, Fenfang [School of Electronic Science and Engineering, Nanjing University, Nanjing 210046 (China)

    2016-03-15

    The avalanche-photodiode-array (APD-array) laser detection and ranging (LADAR) system has been continually developed owing to its superiority of nonscanning, large field of view, high sensitivity, and high precision. However, how to achieve higher-efficient detection and better integration of the LADAR system for real-time three-dimensional (3D) imaging continues to be a problem. In this study, a novel LADAR system using four linear mode APDs (LmAPDs) is developed for high-efficient detection by adopting a modulation and multiplexing technique. Furthermore, an automatic control system for the array LADAR system is proposed and designed by applying the virtual instrumentation technique. The control system aims to achieve four functions: synchronization of laser emission and rotating platform, multi-channel synchronous data acquisition, real-time Ethernet upper monitoring, and real-time signal processing and 3D visualization. The structure and principle of the complete system are described in the paper. The experimental results demonstrate that the LADAR system is capable of achieving real-time 3D imaging on an omnidirectional rotating platform under the control of the virtual instrumentation system. The automatic imaging LADAR system utilized only 4 LmAPDs to achieve 256-pixel-per-frame detection with by employing 64-bit demodulator. Moreover, the lateral resolution is ∼15 cm and range accuracy is ∼4 cm root-mean-square error at a distance of ∼40 m.

  7. Image-Guided Ultrasound Characterization of Volatile Sub-Micron Phase-Shift Droplets in the 20-40 MHz Frequency Range.

    Science.gov (United States)

    Sheeran, Paul S; Daghighi, Yasaman; Yoo, Kimoon; Williams, Ross; Cherin, Emmanuel; Foster, F Stuart; Burns, Peter N

    2016-03-01

    Phase-shift perfluorocarbon droplets are designed to convert from the liquid to the gas state by the external application of acoustic or optical energy. Although droplet vaporization has been investigated extensively at ultrasonic frequencies between 1 and 10 MHz, few studies have characterized performance at the higher frequencies commonly used in small animal imaging. In this study, we use standard B-mode imaging sequences on a pre-clinical ultrasound platform to both image and activate sub-micron decafluorobutane droplet populations in vitro and in vivo at center frequencies in the range of 20-40 MHz. Results show that droplets remain stable against vaporization at low imaging pressures but are vaporized at peak negative pressures near 3.5 MPa at the three frequencies tested. This study also found that a small number of size outliers present in the distribution can greatly influence droplet performance. Removal of these outliers results in a more accurate assessment of the vaporization threshold and produces free-flowing microbubbles upon vaporization in the mouse kidney. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  8. INFLUENCE OF RAW IMAGE PREPROCESSING AND OTHER SELECTED PROCESSES ON ACCURACY OF CLOSE-RANGE PHOTOGRAMMETRIC SYSTEMS ACCORDING TO VDI 2634

    Directory of Open Access Journals (Sweden)

    J. Reznicek

    2016-06-01

    Full Text Available This paper examines the influence of raw image preprocessing and other selected processes on the accuracy of close-range photogrammetric measurement. The examined processes and features includes: raw image preprocessing, sensor unflatness, distance-dependent lens distortion, extending the input observations (image measurements by incorporating all RGB colour channels, ellipse centre eccentricity and target detecting. The examination of each effect is carried out experimentally by performing the validation procedure proposed in the German VDI guideline 2634/1. The validation procedure is based on performing standard photogrammetric measurements of high-accurate calibrated measuring lines (multi-scale bars with known lengths (typical uncertainty = 5 μm at 2 sigma. The comparison of the measured lengths with the known values gives the maximum length measurement error LME, which characterize the accuracy of the validated photogrammetric system. For higher reliability the VDI test field was photographed ten times independently with the same configuration and camera settings. The images were acquired with the metric ALPA 12WA camera. The tests are performed on all ten measurements which gives the possibility to measure the repeatability of the estimated parameters as well. The influences are examined by comparing the quality characteristics of the reference and tested settings.

  9. Application of supervised range-constrained thresholding to extract lung pleura for automated detection of pleural thickenings from thoracic CT images

    Science.gov (United States)

    Chaisaowong, K.; Knepper, A.; Kraus, T.; Aach, T.

    2007-03-01

    We develop an image analysis system to automatically detect pleural thickenings and assess their characteristic values from patients' thoracic spiral CT images. Algorithms are described to carry out the segmentation of pleural contours and to find the pleural thickenings. The method of thresholding was selected as the technique to separate lung's tissue from other. Instead thresholding based only on empirical considerations, the so-called "supervised range-constrained thresholding" is applied. The automatic detection of pleural thickenings is carried out based on the examination of its concavity and on the characteristic Hounsfield unit of tumorous tissue. After detection of pleural thickenings, in order to assess their growth rate, a spline-based interpolation technique is used to create a model of healthy pleura. Based on this healthy model, the size of the pleural thickenings is calculated. In conjunction with the spatio-temporal matching of CT images acquired at different times, the oncopathological assessment of morbidity can be documented. A graphical user interface is provided which is also equipped with 3D visualization of the pleura. Our overall aim is to develop an image analysis system for an efficient and reliable diagnosis of early stage pleural mesothelioma in order to ease the consequences of the expected peak of malignant pleural mesothelioma caused by asbestos exposure.

  10. Testing and Comparison of Imaging Detectors for Electrons in the Energy Range 10–20 keV

    Science.gov (United States)

    Matheson, J.; Moldovan, G.; Kirkland, A.; Allinson, N.; Abrahams, J. P.

    2017-11-01

    Interest in direct detectors for low-energy electrons has increased markedly in recent years. Detection of electrons in the energy range up to low tens of keV is important in techniques such as photoelectron emission microscopy (PEEM) and electron backscatter diffraction (EBSD) on scanning electron microscopes (SEMs). The PEEM technique is used both in the laboratory and on synchrotron light sources worldwide. The ubiquity of SEMs means that there is a very large market for EBSD detectors for materials studies. Currently, the most widely used detectors in these applications are based on indirect detection of incident electrons. Examples include scintillators or microchannel plates (MCPs), coupled to CCD cameras. Such approaches result in blurring in scintillators/phosphors, distortions in optical systems, and inefficiencies due the limited active area of MCPs. In principle, these difficulties can be overcome using direct detection in a semiconductor device. Growing out of a feasibility study into the use of a direct detector for use on an XPEEM, we have built at Rutherford Appleton Laboratory a system to illuminate detectors with an electron beam of energy up to 20 keV . We describe this system in detail. It has been used to measure the performance of a custom back-thinned monolithic active pixel sensor (MAPS), a detector based on the Medipix2 chip, and a commercial detector based on MCPs. We present a selection of the results from these measurements and compare and contrast different detector types.

  11. An Approach to 3d Digital Modeling of Surfaces with Poor Texture by Range Imaging Techniques. `SHAPE from Stereo' VS. `SHAPE from Silhouette' in Digitizing Jorge Oteiza's Sculptures

    Science.gov (United States)

    García Fernández, J.; Álvaro Tordesillas, A.; Barba, S.

    2015-02-01

    Despite eminent development of digital range imaging techniques, difficulties persist in the virtualization of objects with poor radiometric information, in other words, objects consisting of homogeneous colours (totally white, black, etc.), repetitive patterns, translucence, or materials with specular reflection. This is the case for much of the Jorge Oteiza's works, particularly in the sculpture collection of the Museo Fundación Jorge Oteiza (Navarra, Spain). The present study intend to analyse and asses the performance of two digital 3D-modeling methods based on imaging techniques, facing cultural heritage in singular cases, determined by radiometric characteristics as mentioned: Shape from Silhouette and Shape from Stereo. On the other hand, the text proposes the definition of a documentation workflow and presents the results of its application in the collection of sculptures created by Oteiza.

  12. A quantitative analysis of two-dimensional manually segmented transrectal ultrasound axial images in planning high dose rate brachytherapy for prostate cancer

    Directory of Open Access Journals (Sweden)

    Dabić-Stanković Kata

    2017-01-01

    Full Text Available Background/Aim. Prostate delineation, pre-planning and catheter implantation procedures, in high-dose rate brachytherapy (HDR-BT, are commonly based on the prostate manually segmented transrectal ultrasound (TRUS images. The aim of this study was to quantitatively analyze the consistency of prostate capsule delineation, done by a single therapist, prior to each HDR-BT fraction and the changes in the shape of the prostate capsule during HDR-BT, using two dimensional (2D TRUS axial image. Methods. A group of 16 patients were treated at the Medical System Belgrade Brachytherapy Department with definitive HDRBT. The total applied median dose of 52 Gy was divided into four individual fractions, each fraction being delivered 2– 3 weeks apart. Real time prostate axial visualization and the manual segmentation prior to each fraction were performed using B-K Medical ultrasound. Quantitative analyses, analysis of an area and shape were applied on 2D-TRUS axial images of the prostate. Area analyses were used to calculate the average value of the cross-sectional area of the prostate image. The parameters of the prostate shape, the fractal dimension and the circularity ratio of the prostate capsule contour were estimated at the maximum axial cross section of the prostate image. Results. The sample group consisted of four phases, each phase being performed prior to the first, second, third and fourth HDR-BT fraction, respectively. Statistical analysis showed that during HDR-BT fractions there were no significant differences in the average value of area, as well as in the maximum shape of prostate capsule. Conclusions. Quantitative analysis of TRUS axial prostate segmented images shows a successful capsule delineation in the series of manually segmented TRUS images, and the prostate maximum shape remaining unchanged during HDR-BT fractions.

  13. High-resolution observation of field-aligned irregularities in the ionosphere using multi-frequency range imaging of VHF atmospheric radar

    Science.gov (United States)

    Chen, Jenn-Shyong; Furumoto, Jun-ichi; Su, Ching-Lun; Chu, Yen-Hsyang

    Field-aligned irregularity (FAI) in the ionosphere is a topic of interest to atmospheric radar community. In addition to the field-aligned characteristic, quasi-periodic (QP) appearance of FAI echoes has been observed frequently by very-high-frequency (VHF) atmospheric radar. The occurrence range of QP FAI echoes changes with time, and the slope of range versus time can be positive or negative, depending on occurrence time of the echoes. Several mechanisms responsible for the QP FAI echoes have been proposed, e.g., modulation in altitude by a passing atmospheric gravity wave, semidiurnal neutral-wind variation, and so on. Owing to the finite pulse length of radar in observation, the range resolution of measurement is limited within hundreds of meters. In view of this, the range imaging (RIM) using multiple frequencies has been employed to improve the range resolution of measurement. The multi-frequency technique transmits a set of slightly different frequencies sequentially during each radar pulse, and the radar returns at different transmitting frequencies are received, respectively. With adaptive retrieval algorithms for these radar returns, it is capable of resolving the echo structures at meter scale in the range direction. RIM has been employed in the lower atmosphere successfully. In this study, the performance of RIM for FAI was first carried out with the Middle and Upper atmosphere Radar (46 MHz; 34.85(°) N, 136.10(°) N; Japan) and the Chung-Li VHF radar (52 MHz; 24.9(°) N, 121.1(°) E; Taiwan). Some initial results of high-resolution FAI echoes within the range gate will be shown.

  14. Soft x-ray free-electron laser imaging by LiF crystal and film detectors over a wide range of fluences.

    Science.gov (United States)

    Pikuz, Tatiana A; Faenov, Anatoly Ya; Fukuda, Yuji; Kando, Masaki; Bolton, Paul; Mitrofanov, Alexander; Vinogradov, Alexander V; Nagasono, Mitsuru; Ohashi, Haruhiko; Yabashi, Makina; Tono, Kensuke; Senba, Yasunori; Togashi, Tadashi; Ishikawa, Tetsuya

    2013-01-20

    LiF crystal and film detectors were used to measure the far-field fluence profile of a self-amplified spontaneous-emission free-electron laser beam and diffraction imaging with high spatial resolution. In these measurements the photoluminescence (PL) response of LiF crystal and film was compared over a wide range of soft x-ray fluences. It was found that the soft x-ray fluence dependences of LiF crystal and film differ. At low fluence, the LiF crystal shows higher PL response compared to LiF film, while this comparison is the opposite at higher fluence. Accurate measurement of LiF crystal and film PL response is important for precise characterization of the spatial, spectral, and coherence features of x-ray beams across the full profile and in localized areas. For such measurements, crucial LiF detector attributes are high spatial resolution and high dynamic range.

  15. Three-Dimensional ISAR Imaging Method for High-Speed Targets in Short-Range Using Impulse Radar Based on SIMO Array

    Directory of Open Access Journals (Sweden)

    Xinpeng Zhou

    2016-03-01

    Full Text Available This paper proposes a three-dimensional inverse synthetic aperture radar (ISAR imaging method for high-speed targets in short-range using an impulse radar. According to the requirements for high-speed target measurement in short-range, this paper establishes the single-input multiple-output (SIMO antenna array, and further proposes a missile motion parameter estimation method based on impulse radar. By analyzing the motion geometry relationship of the warhead scattering center after translational compensation, this paper derives the receiving antenna position and the time delay after translational compensation, and thus overcomes the shortcomings of conventional translational compensation methods. By analyzing the motion characteristics of the missile, this paper estimates the missile’s rotation angle and the rotation matrix by establishing a new coordinate system. Simulation results validate the performance of the proposed algorithm.

  16. Three-Dimensional ISAR Imaging Method for High-Speed Targets in Short-Range Using Impulse Radar Based on SIMO Array.

    Science.gov (United States)

    Zhou, Xinpeng; Wei, Guohua; Wu, Siliang; Wang, Dawei

    2016-03-11

    This paper proposes a three-dimensional inverse synthetic aperture radar (ISAR) imaging method for high-speed targets in short-range using an impulse radar. According to the requirements for high-speed target measurement in short-range, this paper establishes the single-input multiple-output (SIMO) antenna array, and further proposes a missile motion parameter estimation method based on impulse radar. By analyzing the motion geometry relationship of the warhead scattering center after translational compensation, this paper derives the receiving antenna position and the time delay after translational compensation, and thus overcomes the shortcomings of conventional translational compensation methods. By analyzing the motion characteristics of the missile, this paper estimates the missile's rotation angle and the rotation matrix by establishing a new coordinate system. Simulation results validate the performance of the proposed algorithm.

  17. HDR {sup 192}Ir source speed measurements using a high speed video camera

    Energy Technology Data Exchange (ETDEWEB)

    Fonseca, Gabriel P. [Instituto de Pesquisas Energéticas e Nucleares—IPEN-CNEN/SP, São Paulo 05508-000, Brazil and Department of Radiation Oncology (MAASTRO), GROW School for Oncology and Developmental Biology, Maastricht University Medical Center, Maastricht 6201 BN (Netherlands); Viana, Rodrigo S. S.; Yoriyaz, Hélio [Instituto de Pesquisas Energéticas e Nucleares—IPEN-CNEN/SP, São Paulo 05508-000 (Brazil); Podesta, Mark [Department of Radiation Oncology (MAASTRO), GROW School for Oncology and Developmental Biology, Maastricht University Medical Center, Maastricht 6201 BN (Netherlands); Rubo, Rodrigo A.; Sales, Camila P. de [Hospital das Clínicas da Universidade de São Paulo—HC/FMUSP, São Paulo 05508-000 (Brazil); Reniers, Brigitte [Department of Radiation Oncology - MAASTRO, GROW School for Oncology and Developmental Biology, Maastricht University Medical Center, Maastricht 6201 BN (Netherlands); Research Group NuTeC, CMK, Hasselt University, Agoralaan Gebouw H, Diepenbeek B-3590 (Belgium); Verhaegen, Frank, E-mail: frank.verhaegen@maastro.nl [Department of Radiation Oncology - MAASTRO, GROW School for Oncology and Developmental Biology, Maastricht University Medical Center, Maastricht 6201 BN (Netherlands); Medical Physics Unit, Department of Oncology, McGill University, Montréal, Québec H3G 1A4 (Canada)

    2015-01-15

    Purpose: The dose delivered with a HDR {sup 192}Ir afterloader can be separated into a dwell component, and a transit component resulting from the source movement. The transit component is directly dependent on the source speed profile and it is the goal of this study to measure accurate source speed profiles. Methods: A high speed video camera was used to record the movement of a {sup 192}Ir source (Nucletron, an Elekta company, Stockholm, Sweden) for interdwell distances of 0.25–5 cm with dwell times of 0.1, 1, and 2 s. Transit dose distributions were calculated using a Monte Carlo code simulating the source movement. Results: The source stops at each dwell position oscillating around the desired position for a duration up to (0.026 ± 0.005) s. The source speed profile shows variations between 0 and 81 cm/s with average speed of ∼33 cm/s for most of the interdwell distances. The source stops for up to (0.005 ± 0.001) s at nonprogrammed positions in between two programmed dwell positions. The dwell time correction applied by the manufacturer compensates the transit dose between the dwell positions leading to a maximum overdose of 41 mGy for the considered cases and assuming an air-kerma strength of 48 000 U. The transit dose component is not uniformly distributed leading to over and underdoses, which is within 1.4% for commonly prescribed doses (3–10 Gy). Conclusions: The source maintains its speed even for the short interdwell distances. Dose variations due to the transit dose component are much lower than the prescribed treatment doses for brachytherapy, although transit dose component should be evaluated individually for clinical cases.

  18. Evaluation of PC-ISO for customized, 3D Printed, gynecologic 192-Ir HDR brachytherapy applicators.

    Science.gov (United States)

    Cunha, J Adam M; Mellis, Katherine; Sethi, Rajni; Siauw, Timmy; Sudhyadhom, Atchar; Garg, Animesh; Goldberg, Ken; Hsu, I-Chow; Pouliot, Jean

    2015-01-08

    The purpose of this study was to evaluate the radiation attenuation properties of PC-ISO, a commercially available, biocompatible, sterilizable 3D printing material, and its suitability for customized, single-use gynecologic (GYN) brachytherapy applicators that have the potential for accurate guiding of seeds through linear and curved internal channels. A custom radiochromic film dosimetry apparatus was 3D-printed in PC-ISO with a single catheter channel and a slit to hold a film segment. The apparatus was designed specifically to test geometry pertinent for use of this material in a clinical setting. A brachytherapy dose plan was computed to deliver a cylindrical dose distribution to the film. The dose plan used an 192Ir source and was normalized to 1500 cGy at 1 cm from the channel. The material was evaluated by comparing the film exposure to an identical test done in water. The Hounsfield unit (HU) distributions were computed from a CT scan of the apparatus and compared to the HU distribution of water and the HU distribution of a commercial GYN cylinder applicator. The dose depth curve of PC-ISO as measured by the radiochromic film was within 1% of water between 1 cm and 6 cm from the channel. The mean HU was -10 for PC-ISO and -1 for water. As expected, the honeycombed structure of the PC-ISO 3D printing process created a moderate spread of HU values, but the mean was comparable to water. PC-ISO is sufficiently water-equivalent to be compatible with our HDR brachytherapy planning system and clinical workflow and, therefore, it is suitable for creating custom GYN brachytherapy applicators. Our current clinical practice includes the use of custom GYN applicators made of commercially available PC-ISO when doing so can improve the patient's treatment. 

  19. The influence of the dwell time deviation constraint (DTDC) parameter on dosimetry with IPSA optimisation for HDR prostate brachytherapy.

    Science.gov (United States)

    Smith, Ryan L; Panettieri, Vanessa; Lancaster, Craig; Mason, Natasha; Franich, Rick D; Millar, Jeremy L

    2015-03-01

    To investigate how the dwell time deviation constraint (DTDC) parameter, applied to inverse planning by simulated annealing (IPSA) optimisation limits large dwell times from occurring in each catheter and to characterise the effect on the resulting dosimetry for prostate high dose rate (HDR) brachytherapy treatment plans. An unconstrained IPSA optimised treatment plan, using the Oncentra Brachytherapy treatment planning system (version 4.3, Nucletron an Elekta company, Elekta AB, Stockholm, Sweden), was generated for 20 consecutive HDR prostate brachytherapy patients, with the DTDC set to zero. Successive constrained optimisation plans were also created for each patient by increasing the DTDC parameter by 0.2, up to a maximum value of 1.0. We defined a "plan modulation index", to characterise the change of dwell time modulation as the DTDC parameter was increased. We calculated the dose volume histogram indices for the PTV (D90, V100, V150, V200%) and urethra (D10%) to characterise the effect on the resulting dosimetry. The average PTV D90% decreases as the DTDC is applied, on average by only 1.5 %, for a DTDC = 0.4. The measures of high dose regions in the PTV, V150 and V200%, increase on average by less than 5 and 2 % respectively. The net effect of DTDC on the modulation of dwell times has been characterised by the introduction of the plan modulation index. DTDC applied during IPSA optimisation of HDR prostate brachytherapy plans reduce the occurrence of large isolated dwell times within individual catheters. The mechanism by which DTDC works has been described and its effect on the modulation of dwell times has been characterised. The authors recommend using a DTDC parameter no greater than 0.4 to obtain a plan with dwell time modulation comparable to a geometric optimised plan. This yielded on average a 1.5 % decrease in PTV coverage and an acceptable increase in V150%, without compromising the urethral dose.

  20. SU-C-16A-05: OAR Dose Tolerance Recommendations for Prostate and Cervical HDR Brachytherapy: Dose Versus Volume Metrics

    Energy Technology Data Exchange (ETDEWEB)

    Geneser, S; Cunha, J; Pouliot, J; Hsu, I [UC San Francisco, San Francisco, CA (United States)

    2014-06-15

    Purpose: HDR brachytherapy consensus dose tolerance recommendations for organs at risk (OARs) remain widely debated. Prospective trials reporting metrics must be sufficiently data-dense to assess adverse affects and identify optimally predictive tolerances. We explore the tradeoffs between reporting dose-metrics versus volume-metrics and the potential impact on trial outcome analysis and tolerance recommendations. Methods: We analyzed 26 prostate patients receiving 15 Gy HDR single-fraction brachytherapy boost to 45 Gy external beam radiation therapy and 28 cervical patients receiving 28 Gy HDR brachytherapy monotherapy in 4 fractions using 2 implants. For each OAR structure, a robust linear regression fit was performed for the dose-metrics as a function of the volume-metrics. The plan quality information provided by recommended dose-metric and volume-metric values were compared. Results: For prostate rectal dose, D2cc and V75 lie close to the regression line, indicating they are similarly informative. Two outliers for prostate urethral dose are substantially different from the remaining cohort in terms of D0.1cc and V75, but not D1cc, suggesting the choice of reporting dose metric is essential. For prostate bladder and cervical bladder, rectum, and bowel, dose outliers are more apparent via V75 than recommended dose-metrics. This suggests that for prostate bladder dose and all cervical OAR doses, the recommended volume-metrics may be better predictors of clinical outcome than dose-metrics. Conclusion: For plan acceptance criteria, dose and volume-metrics are reciprocally equivalent. However, reporting dosemetrics or volume-metrics alone provides substantially different information. Our results suggest that volume-metrics may be more sensitive to differences in planned dose, and if one metric must be chosen, volumemetrics are preferable. However, reporting discrete DVH points severely limits the ability to identify planning tolerances most predictive of adverse

  1. Images

    Data.gov (United States)

    National Aeronautics and Space Administration — Images for the website main pages and all configurations. The upload and access points for the other images are: Website Template RSW images BSCW Images HIRENASD...

  2. STUDY ON THE FEASIBILITY OF RGB SUBSTITUTE CIR FOR AUTOMATIC REMOVAL VEGETATION OCCLUSION BASED ON GROUND CLOSE-RANGE BUILDING IMAGES

    Directory of Open Access Journals (Sweden)

    C. Li

    2012-07-01

    Full Text Available Building 3D reconstruction based on ground remote sensing data (image, video and lidar inevitably faces the problem that buildings are always occluded by vegetation, so how to automatically remove and repair vegetation occlusion is a very important preprocessing work for image understanding, compute vision and digital photogrammetry. In the traditional multispectral remote sensing which is achieved by aeronautics and space platforms, the Red and Near-infrared (NIR bands, such as NDVI (Normalized Difference Vegetation Index, are useful to distinguish vegetation and clouds, amongst other targets. However, especially in the ground platform, CIR (Color Infra Red is little utilized by compute vision and digital photogrammetry which usually only take true color RBG into account. Therefore whether CIR is necessary for vegetation segmentation or not has significance in that most of close-range cameras don’t contain such NIR band. Moreover, the CIE L*a*b color space, which transform from RGB, seems not of much interest by photogrammetrists despite its powerfulness in image classification and analysis. So, CIE (L, a, b feature and support vector machine (SVM is suggested for vegetation segmentation to substitute for CIR. Finally, experimental results of visual effect and automation are given. The conclusion is that it's feasible to remove and segment vegetation occlusion without NIR band. This work should pave the way for texture reconstruction and repair for future 3D reconstruction.

  3. Quantification of normative ranges and baseline predictors of aortoventricular interface dimensions using multi-detector computed tomographic imaging in patients without aortic valve disease

    Energy Technology Data Exchange (ETDEWEB)

    Gooley, Robert P., E-mail: robert.gooley@monashhealth.org [MonashHeart, Monash Health, Melbourne 3168 (Australia); Monash Cardiovascular Research Centre, Department of Medicine (MMC), Monash University, Melbourne 3168 (Australia); Cameron, James D., E-mail: james.cameron@monash.edu [MonashHeart, Monash Health, Melbourne 3168 (Australia); Monash Cardiovascular Research Centre, Department of Medicine (MMC), Monash University, Melbourne 3168 (Australia); Soon, Jennifer, E-mail: jenn.sa@gmail.com [MonashHeart, Monash Health, Melbourne 3168 (Australia); Monash Cardiovascular Research Centre, Department of Medicine (MMC), Monash University, Melbourne 3168 (Australia); Loi, Duncan, E-mail: dloi2@student.monash.edu [Monash Cardiovascular Research Centre, Department of Medicine (MMC), Monash University, Melbourne 3168 (Australia); Chitale, Gauri, E-mail: gchi21@student.monash.edu [Monash Cardiovascular Research Centre, Department of Medicine (MMC), Monash University, Melbourne 3168 (Australia); Syeda, Rifath, E-mail: rssye1@student.monash.edu [Monash Cardiovascular Research Centre, Department of Medicine (MMC), Monash University, Melbourne 3168 (Australia); Meredith, Ian T., E-mail: ian.meredith@myheart.id.au [MonashHeart, Monash Health, Melbourne 3168 (Australia); Monash Cardiovascular Research Centre, Department of Medicine (MMC), Monash University, Melbourne 3168 (Australia)

    2015-09-15

    Highlights: • MDCT imaging of the aortoventricular interface is increasingly common. • We present normative ranges for aortoventricular interface dimensions. • Such techniques and ranges should be used to standardise reporting and research. - Abstract: Background: Multidetector computed tomographic (MDCT) assessment of the aortoventricular interface has gained increased importance with the advent of minimally invasive treatment modalities for aortic and mitral valve disease. This has included a standardised technique of identifying a plane through the nadir of each coronary cusp, the basal plane, and taking further measurements in relation to this plane. Despite this there is no published data defining normal ranges for these aortoventricular metrics in a healthy cohort. This study seeks to quantify normative ranges for MDCT derived aortoventricular dimensions and evaluate baseline demographic and anthropomorphic associates of these measurements in a normal cohort. Methods: 250 consecutive patients undergoing MDCT coronary angiography were included. Aortoventricular dimensions at multiple levels of the aortoventricular interface were assessed and normative ranges quantified. Multivariate linear regression was performed to identify baseline predictors of each metric. Results: The mean age was 59 ± 12 years. The basal plane was eccentric (EI = 0.22 ± 0.06) while the left ventricular outflow tract was more eccentric (EI = 0.32 ±0.06), with no correlation to gender, age or hypertension. Male gender, height and body mass index were consistent independent predictors of larger aortoventricular dimensions at all anatomical levels, while age was predictive of supra-annular measurements. Conclusions: Male gender, height and BMI are independent predictors of all aortoventricular dimensions while age predicts only supra-annular dimensions. Use of defined metrics such as the basal plane and formation of normative ranges for these metrics allows reference for clinical

  4. Segmentation of brain magnetic resonance images based on multi-atlas likelihood fusion: testing using data with a broad range of anatomical and photometric profiles.

    Science.gov (United States)

    Tang, Xiaoying; Crocetti, Deana; Kutten, Kwame; Ceritoglu, Can; Albert, Marilyn S; Mori, Susumu; Mostofsky, Stewart H; Miller, Michael I

    2015-01-01

    We propose a hierarchical pipeline for skull-stripping and segmentation of anatomical structures of interest from T1-weighted images of the human brain. The pipeline is constructed based on a two-level Bayesian parameter estimation algorithm called multi-atlas likelihood fusion (MALF). In MALF, estimation of the parameter of interest is performed via maximum a posteriori estimation using the expectation-maximization (EM) algorithm. The likelihoods of multiple atlases are fused in the E-step while the optimal estimator, a single maximizer of the fused likelihoods, is then obtained in the M-step. There are two stages in the proposed pipeline; first the input T1-weighted image is automatically skull-stripped via a fast MALF, then internal brain structures of interest are automatically extracted using a regular MALF. We assess the performance of each of the two modules in the pipeline based on two sets of images with markedly different anatomical and photometric contrasts; 3T MPRAGE scans of pediatric subjects with developmental disorders vs. 1.5T SPGR scans of elderly subjects with dementia. Evaluation is performed quantitatively using the Dice overlap as well as qualitatively via visual inspections. As a result, we demonstrate subject-level differences in the performance of the proposed pipeline, which may be accounted for by age, diagnosis, or the imaging parameters (particularly the field strength). For the subcortical and ventricular structures of the two datasets, the hierarchical pipeline is capable of producing automated segmentations with Dice overlaps ranging from 0.8 to 0.964 when compared with the gold standard. Comparisons with other representative segmentation algorithms are presented, relative to which the proposed hierarchical pipeline demonstrates comparative or superior accuracy.

  5. Segmentation of brain magnetic resonance images based on multi-atlas likelihood fusion: testing using data with a broad range of anatomical and photometric profiles

    Directory of Open Access Journals (Sweden)

    Xiaoying eTang

    2015-03-01

    Full Text Available We propose a hierarchical pipeline for skull-stripping and segmentation of anatomical structures of interest from T1-weighted images of the human brain. The pipeline is constructed based on a two-level Bayesian parameter estimation algorithm called multi-atlas likelihood fusion (MALF. In MALF, estimation of the parameter of interest is performed via maximum a posteriori estimation using the expectation-maximization (EM algorithm. The likelihoods of multiple atlases are fused in the E-step while the optimal estimator, a single maximizer of the fused likelihoods, is then obtained in the M-step. There are two stages in the proposed pipeline; first the input T1-weighted image is automatically skull-stripped via a fast MALF, then internal brain structures of interest are automatically extracted using a regular MALF. We assess the performance of each of the two modules in the pipeline based on two sets of images with markedly different anatomical and photometric contrasts; 3T MPRAGE scans of pediatric subjects with developmental disorders versus 1.5T SPGR scans of elderly subjects with dementia. Evaluation is performed quantitatively using the Dice overlap as well as qualitatively via visual inspections. As a result, we demonstrate subject-level differences in the performance of the proposed pipeline, which may be accounted for by age, diagnosis, or the imaging parameters (particularly the field strength. For the subcortical and ventricular structures of the two datasets, the hierarchical pipeline is capable of producing automated segmentations with Dice overlaps ranging from 0.8 to 0.964 when compared with the gold standard. Comparisons with other representative segmentation algorithms are presented, relative to which the proposed hierarchical pipeline demonstrates comparative or superior accuracy.

  6. Mercury: The Image of the Planet in the 210°-285° W Longitude Range Obtained by the Short-Exposure Method

    Science.gov (United States)

    Ksanfomality, L. V.

    2003-11-01

    For the purpose of obtaining images of the unknown portion of Mercury, we continued the previously started series of observations of this planet by the short exposure method. Several thousand electronic images of Mercury have been acquired on 1-2 May 2002 under good meteorological conditions at the high-altitude Skinakas Astrophysical Observatory of Iraklion University (Crete, Greece, 35°13' E, 24°54' N) during the evening elongation. The phase angle of Mercury was 95°-99° and the observed range of longitudes was 210°-285° W. Observations were carried out using Ritchy-Chrétien telescope (D = 1.29 m, F = 9.857 m) with the KS 19 filter cutting wavelengths shorter than about 700 nm. The planet's disk was seen, on average, at an angle of 7.75'' arcsec. The image scale was equal to 47.8 μm/arcsec. We used a CCD with a pixel size of 7.4 × 7.4 μm in the regime of short exposures. By processing a great number of electronic images, we succeeded in obtaining a sufficiently distinct synthesized image of the unknown portion of Mercury's surface. The most prominent formation in this region is a giant basin (or cratered ``mare'') centered at about 8° N, 280° W, which was given a working name ``Skinakas basin'' (after the name of the observatory where observations were made). By its size, the interior part of this basin exceeds the largest lunar Mare Imbrium. As opposed to Mare Imbrium, the Skinakas basin is presumably of impact origin. Its relief resembles that of Caloris Planitia but the size is much larger. A series of smaller formations are also seen on synthesized images. The resolution obtained on the surface of Mercury is about 100 km, which is close to the telescope diffraction limit. Also considered are the published theoretical estimations of the possible advantages offered by the short exposure method. Some results obtained by other research groups are discussed.

  7. Comparison of 3D dose distributions for HDR 192Ir brachytherapy sources with normoxic polymer gel dosimetry and treatment planning system.

    Science.gov (United States)

    Senkesen, Oznur; Tezcanli, Evrim; Buyuksarac, Bora; Ozbay, Ismail

    2014-01-01

    Radiation fluence changes caused by the dosimeter itself and poor spatial resolution may lead to lack of 3-dimensional (3D) information depending on the features of the dosimeter and quality assurance of dose distributions for high-dose rate (HDR) iridium-192 ((192)Ir) brachytherapy sources is challenging and experimental dosimetry methods used for brachytherapy sources are limited. In this study, we investigated 3D dose distributions of (192)Ir brachytherapy sources for irradiation with single and multiple dwell positions using a normoxic gel dosimeter and compared them with treatment planning system (TPS) calculations. For dose calibration purposes, 100-mL gel-containing vials were irradiated at predefined doses and then scanned in an magnetic resonance (MR) imaging unit. Gel phantoms prepared in 2 spherical glasses were irradiated with (192)Ir for the calculated dwell positions, and MR scans of the phantoms were obtained. The images were analyzed with MATLAB software. Dose distributions and profiles derived with 1-mm resolution were compared with TPS calculations. Linearity was observed between the delivered dose and the reciprocal of the T2 relaxation time constant of the gel. The x-, y-, and z-axes were defined as the sagittal, coronal, and axial planes, respectively, the sagittal and axial planes were defined parallel to the long axis of the source while the coronal plane was defined horizontally to the long axis of the source. The differences between measured and calculated profile widths of 3-cm source length and point source for 70%, 50%, and 30% isodose lines were evaluated at 3 dose levels using 18 profiles of comparison. The calculations for 3-cm source length revealed a difference of > 3mm in 1 coordinate at 50% profile width on the sagittal plane and 3 coordinates at 70% profile width and 2 coordinates at 50% and 30% profile widths on the axial plane. Calculations on the coronal plane for 3-cm source length showed > 3-mm difference in 1 coordinate at

  8. Quantitative in vivo 23Na MR imaging of the healthy human kidney: determination of physiological ranges at 3.0T with comparison to DWI and BOLD.

    Science.gov (United States)

    Haneder, Stefan; Kettnaker, Paul; Konstandin, Simon; Morelli, John N; Schad, Lothar R; Schoenberg, Stefan O; Michaely, Henrik J

    2013-12-01

    The purpose of this prospective study was to assess the normal physiologic ranges of the renal corticomedullary 23Na-concentration ([23Na]) gradient at 3.0T in healthy volunteers. The corticomedullary [23Na] gradient was correlated with other functional MR imaging parameters--blood oxygenation level dependent (BOLD) and diffusion-weighted imaging (DWI)--and to individual and physiologic parameters--age, gender, estimated glomerular filtration rate (eGFR), body mass index (BMI), and blood serum sodium concentration ([23Na]serum). 50 healthy volunteers (30 m, 20 w; mean age: 29.2 years) were included in this IRB-approved study, without a specific a priori preparation in regard to water or food intake. For 23Na-imaging a 3D density adapted, radial gradient echo (GRE)-sequence (spatial resolution=5×5×5 mm3) was used in combination with a dedicated 23Na-coil and 23Na-reference phantoms. [23Na] values of the corticomedullary [23Na] gradient were measured by placement of a linear region of interest (20×1 mm2) from the renal cortex in the direction of the renal medulla. By using external standard reference phantoms, [23Na] was calculated in mmol/L of wet tissue volume (mmol/l WTV). Axial diffusion-weighted images (spatial resolution=1.7×1.7×5.0 mm3) and 2D GRE BOLD images (spatial resolution=1.2×1.2×4.0 mm3) were acquired. Mean values±standard deviations for [23Na], apparent diffusion coefficient (ADC) values, and R2* values were computed for each volunteer. The corticomedullary 23Na-concentration gradient (in mmol/l/mm) was calculated along the area of linear concentration increase from the cortex in the direction of the medulla. Correlations between the [23Na] and DWI, BOLD, and the physiologic parameters were assessed with Pearson correlation coefficients. The mean corticomedullary [23Na] for all healthy volunteers increased from the renal cortex (58±17 mmol/l WTV) in the direction of the medulla (99±18 mmol/l WTV). The inter-individual differences ranged from

  9. Investigation of Dosimetric Parameters of $^{192}$Ir MicroSelectron v2 HDR Brachytherapy Source Using EGSnrc Monte Carlo Code

    CERN Document Server

    Naeem, Hamza; Zheng, Huaqing; Cao, Ruifen; Pei, Xi; Hu, Liqin; Wu, Yican

    2016-01-01

    The $^{192}$Ir sources are widely used for high dose rate (HDR) brachytherapy treatments. The aim of this study is to simulate $^{192}$Ir MicroSelectron v2 HDR brachytherapy source and calculate the air kerma strength, dose rate constant, radial dose function and anisotropy function established in the updated AAPM Task Group 43 protocol. The EGSnrc Monte Carlo (MC) code package is used to calculate these dosimetric parameters, including dose contribution from secondary electron source and also contribution of bremsstrahlung photons to air kerma strength. The Air kerma strength, dose rate constant and radial dose function while anisotropy functions for the distance greater than 0.5 cm away from the source center are in good agreement with previous published studies. Obtained value from MC simulation for air kerma strength is $9.762\\times 10^{-8} \\textrm{UBq}^{-1}$and dose rate constant is $1.108\\pm 0.13\\%\\textrm{cGyh}^{-1} \\textrm{U}^{-1}$.

  10. Temperature- and frequency-dependent dielectric properties of biological tissues within the temperature and frequency ranges typically used for magnetic resonance imaging-guided focused ultrasound surgery.

    Science.gov (United States)

    Fu, Fanrui; Xin, Sherman Xuegang; Chen, Wufan

    2014-02-01

    This study aimed to obtain the temperature- and frequency-dependent dielectric properties of tissues subjected to magnetic resonance (MR) scanning for MR imaging-guided focused ultrasound surgery (MRgFUS). These variables are necessary to calculate radio frequency electromagnetic fields distribution and specific radio frequency energy absorption rate (SAR) in the healthy tissues surrounding the target tumours, and their variation may affect the efficacy of advanced RF pulses. The dielectric properties of porcine uterus, liver, kidney, urinary bladder, skeletal muscle, and fat were determined using an open-ended coaxial probe method. The temperature range was set from 36 °C to 60 °C; and the frequencies were set at 42.58 (1 T), 64 (1.5 T), 128 (3 T), 170 (4 T), 298 (7 T), 400 (9 T), and 468 MHz (11 T). Within the temperature and frequency ranges, the dielectric constants were listed as follows: uterus 49.6-121.64, liver 44.81-127.68, kidney 37.3-169.26, bladder 42.43-125.95, muscle 58.62-171.7, and fat 9.2327-20.2295. The following conductivities were obtained at the same temperature and frequency ranges: uterus 0.5506-1.4419, liver 0.5174-0.9709, kidney 0.8061-1.3625, bladder 0.6766-1.1817, muscle 0.8983-1.3083, and fat 0.1552-0.2316. The obtained data are consistent with the temperature and frequency ranges typically used in MRgFUS and thus can be used as reference to calculate radio frequency electromagnetic fields and SAR distribution inside the healthy tissues subjected to MR scanning for MRgFUS.

  11. Smart-pixel for 3D ranging imagers based on single-photon avalanche diode and time-to-digital converter

    Science.gov (United States)

    Markovic, Bojan; Tisa, Simone; Tosi, Alberto; Zappa, Franco

    2011-05-01

    We present a "smart-pixel" suitable for implementation of monolithic single-photon imaging arrays aimed at 3D ranging applications by means of the direct time-of-flight detection (like LIDAR systems), but also for photon timing applications (like FLIM, FCS, FRET). The pixel includes a Single-Photon Avalanche Diode (SPAD) and a Time-to-Digital Converter (TDC) monolithically designed and manufactured in the same chip, and it is able to detect single photons and to measure in-pixel the time delay between a START signal (e.g. laser excitation, LIDAR flash) and a photon detection (e.g. back reflection from a target object). In order to provide both wide dynamic range, high time resolution and very high linearity, we devised a TDC architecture based on an interpolation technique. A "coarse" counter counts the number of reference-clock rising-edges between START and STOP, while high resolution is achieved by means of two interpolators, which measure the time elapsed between START (and STOP) signal and a successive clock edge. In an array with many pixels, multiple STOP channels are needed while just one START channel is necessary if the START event is common to all channels. We report on the design and characterization of prototype circuits, fabricated in a 0.35 μm standard CMOS technology containing complete conversion channels (i.e. 20-μm active-area diameter SPAD, quenching circuitry, and TDC). With a 100 MHz reference clock, the TDC provides a time resolution of 10 ps, a dynamic range of 160 ns and DNL < 1% LSB rms.

  12. Increasing Fractional Doses Increases the Probability of Benign PSA Bounce in Patients Undergoing Definitive HDR Brachytherapy for Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Hauck, Carlin R.; Ye, Hong; Chen, Peter Y.; Gustafson, Gary S.; Limbacher, Amy; Krauss, Daniel J., E-mail: Daniel.krauss@beaumont.edu

    2017-05-01

    Purpose: Prostate-specific antigen (PSA) bounce is a temporary elevation of the PSA level above a prior nadir. The purpose of this study was to determine whether the frequency of a PSA bounce following high-dose-rate (HDR) interstitial brachytherapy for the treatment of prostate cancer is associated with individual treatment fraction size. Methods and Materials: Between 1999 and 2014, 554 patients underwent treatment of low- or intermediate-risk prostate cancer with definitive HDR brachytherapy as monotherapy and had ≥3 subsequent PSA measurements. Four different fraction sizes were used: 950 cGy × 4 fractions, 1200 cGy × 2 fractions, 1350 cGy × 2 fractions, 1900 cGy × 1 fraction. Four definitions of PSA bounce were applied: ≥0.2, ≥0.5, ≥1.0, and ≥2.0 ng/mL above the prior nadir with a subsequent return to the nadir. Results: The median follow-up period was 3.7 years. The actuarial 3-year rate of PSA bounce for the entire cohort was 41.3%, 28.4%, 17.4%, and 6.8% for nadir +0.2, +0.5, +1.0, and +2.0 ng/mL, respectively. The 3-year rate of PSA bounce >0.2 ng/mL was 42.2%, 32.1%, 41.0%, and 59.1% for the 950-, 1200-, 1350-, and 1900-cGy/fraction levels, respectively (P=.002). The hazard ratio for bounce >0.2 ng/mL for patients receiving a single fraction of 1900 cGy compared with those receiving treatment in multiple fractions was 1.786 (P=.024). For patients treated with a single 1900-cGy fraction, the 1-, 2-, and 3-year rates of PSA bounce exceeding the Phoenix biochemical failure definition (nadir +2 ng/mL) were 4.5%, 18.7%, and 18.7%, respectively, higher than the rates for all other administered dose levels (P=.025). Conclusions: The incidence of PSA bounce increases with single-fraction HDR treatment. Knowledge of posttreatment PSA kinetics may aid in decision making regarding management of potential biochemical failures.

  13. Radiobiological evaluation of the influence of dwell time modulation restriction in HIPO optimized HDR prostate brachytherapy implants.

    Science.gov (United States)

    Mavroidis, Panayiotis; Katsilieri, Zaira; Kefala, Vasiliki; Milickovic, Natasa; Papanikolaou, Nikos; Karabis, Andreas; Zamboglou, Nikolaos; Baltas, Dimos

    2010-09-01

    One of the issues that a planner is often facing in HDR brachytherapy is the selective existence of high dose volumes around some few dominating dwell positions. If there is no information available about its necessity (e.g. location of a GTV), then it is reasonable to investigate whether this can be avoided. This effect can be eliminated by limiting the free modulation of the dwell times. HIPO, an inverse treatment plan optimization algorithm, offers this option. In treatment plan optimization there are various methods that try to regularize the variation of dose non-uniformity using purely dosimetric measures. However, although these methods can help in finding a good dose distribution they do not provide any information regarding the expected treatment outcome as described by radiobiology based indices. The quality of 12 clinical HDR brachytherapy implants for prostate utilizing HIPO and modulation restriction (MR) has been compared to alternative plans with HIPO and free modulation (without MR). All common dose-volume indices for the prostate and the organs at risk have been considered together with radiobiological measures. The clinical effectiveness of the different dose distributions was investigated by calculating the response probabilities of the tumors and organs-at-risk (OARs) involved in these prostate cancer cases. The radiobiological models used are the Poisson and the relative seriality models. Furthermore, the complication-free tumor control probability, P+ and the biologically effective uniform dose ([Formula: see text]) were used for treatment plan evaluation and comparison. Our results demonstrate that HIPO with a modulation restriction value of 0.1-0.2 delivers high quality plans which are practically equivalent to those achieved with free modulation regarding the clinically used dosimetric indices. In the comparison, many of the dosimetric and radiobiological indices showed significantly different results. The modulation restricted clinical

  14. Radiobiological evaluation of the influence of dwell time modulation restriction in HIPO optimized HDR prostate brachytherapy implants

    Directory of Open Access Journals (Sweden)

    Dimos Baltas

    2010-10-01

    Full Text Available Purpose: One of the issues that a planner is often facing in HDR brachytherapy is the selective existence of high dose volumes around some few dominating dwell positions. If there is no information available about its necessity (e.g. location of a GTV, then it is reasonable to investigate whether this can be avoided. This effect can be eliminated by limiting the free modulation of the dwell times. HIPO, an inverse treatment plan optimization algorithm, offers this option.In treatment plan optimization there are various methods that try to regularize the variation of dose non-uniformity using purely dosimetric measures. However, although these methods can help in finding a good dose distribution they do not provide any information regarding the expected treatment outcome as described by radiobiology based indices.Material and methods: The quality of 12 clinical HDR brachytherapy implants for prostate utilizing HIPO and modulation restriction (MR has been compared to alternative plans with HIPO and free modulation (without MR.All common dose-volume indices for the prostate and the organs at risk have been considered together with radiobiological measures. The clinical effectiveness of the different dose distributions was investigated by calculating the response probabilities of the tumors and organs-at-risk (OARs involved in these prostate cancer cases. The radiobiological models used are the Poisson and the relative seriality models. Furthermore, the complication-free tumor control probability, P+ and the biologically effective uniform dose (D = were used for treatment plan evaluation and comparison.Results: Our results demonstrate that HIPO with a modulation restriction value of 0.1-0.2 delivers high quality plans which are practically equivalent to those achieved with free modulation regarding the clinically used dosimetric indices.In the comparison, many of the dosimetric and radiobiological indices showed significantly different results. The

  15. SU-E-T-459: Impact of Source Position and Traveling Time On HDR Skin Surface Applicator Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, J; Barker, C; Zaider, M; Cohen, G [Memorial Sloan Kettering Cancer Center, New York, NY (United States)

    2015-06-15

    Purpose: Observed dosimetric discrepancy between measured and treatment planning system (TPS) predicted values, during applicator commissioning, were traced to source position uncertainty in the applicator. We quantify the dosimetric impact of this geometric uncertainty, and of the source traveling time inside the applicator, and propose corrections for clinical use. Methods: We measured the dose profiles from the Varian Leipzig-style (horizontal) HDR skin applicator, using EBT3 film, photon diode, and optically stimulated luminescence dosimeter (OSLD) and three different GammaMed HDR afterloders. The dose profiles and depth dose of each aperture were measured at several depths (up to about 10 mm, depending on the dosimeter). The measured dose profiles were compared with Acuros calculated profiles in BrachyVision TPS. For the impact of the source position, EBT3 film measurements were performed with applicator, facing-down and facing-up orientations. The dose with and without source traveling was measured with diode detector using HDR timer and electrometer timer, respectively. Results: Depth doses measured using the three dosimeters were in good agreement, but were consistently higher than the Acuros dose calculations. Measurements with the applicator facing-up were significantly lower than those in the facing-down position with maximum difference of about 18% at the surface, due to source sag inside the applicator. Based on the inverse-square law, the effective source sag was evaluated to be about 0.5 mm from the planned position. The additional dose from the source traveling was about 2.8% for 30 seconds with 10 Ci source, decreasing with increased dwelling time and decreased source activity. Conclusion: Due to the short source-to-surface distance of the applicator, the small source sag inside the applicator has significant dosimetric impact, which should be considered before the clinical use of the applicator. Investigation of the effect for other applicators

  16. Spectral Unmixing of Forest Crown Components at Close Range, Airborne and Simulated Sentinel-2 and EnMAP Spectral Imaging Scale

    Directory of Open Access Journals (Sweden)

    Anne Clasen

    2015-11-01

    Full Text Available Forest biochemical and biophysical variables and their spatial and temporal distribution are essential inputs to process-orientated ecosystem models. To provide this information, imaging spectroscopy appears to be a promising tool. In this context, the present study investigates the potential of spectral unmixing to derive sub-pixel crown component fractions in a temperate deciduous forest ecosystem. However, the high proportion of foliage in this complex vegetation structure leads to the problem of saturation effects, when applying broadband vegetation indices. This study illustrates that multiple endmember spectral mixture analysis (MESMA can contribute to overcoming this challenge. Reference fractional abundances, as well as spectral measurements of the canopy components, could be precisely determined from a crane measurement platform situated in a deciduous forest in North-East Germany. In contrast to most other studies, which only use leaf and soil endmembers, this experimental setup allowed for the inclusion of a bark endmember for the unmixing of components within the canopy. This study demonstrates that the inclusion of additional endmembers markedly improves the accuracy. A mean absolute error of 7.9% could be achieved for the fractional occurrence of the leaf endmember and 5.9% for the bark endmember. In order to evaluate the results of this field-based study for airborne and satellite-based remote sensing applications, a transfer to Airborne Imaging Spectrometer for Applications (AISA and simulated Environmental Mapping and Analysis Program (EnMAP and Sentinel-2 imagery was carried out. All sensors were capable of unmixing crown components with a mean absolute error ranging between 3% and 21%.

  17. Image-Based and Range-Based 3d Modelling of Archaeological Cultural Heritage: the Telamon of the Temple of Olympian ZEUS in Agrigento (italy)

    Science.gov (United States)

    Lo Brutto, M.; Spera, M. G.

    2011-09-01

    The Temple of Olympian Zeus in Agrigento (Italy) was one of the largest temple and at the same time one of the most original of all the Greek architecture. We don't know exactly how it was because the temple is now almost completely destroyed but it is very well-known for the presence of the Telamons. The Telamons were giant statues (about 8 meters high) probably located outside the temple to fill the interval between the columns. In accordance with the theory most accredited by archaeologists the Telamons were a decorative element and also a support for the structure. However, this hypothesis has never been scientifically proven. One Telamon has been reassembled and is shown at the Archaeological Museum of Agrigento. In 2009 a group of researchers at the University of Palermo has begun a study to test the hypothesis that the Telamons support the weight of the upper part of the temple. The study consists of a 3D survey of the Telamon, to reconstruct a detailed 3D digital model, and of a structural analysis with the Finite Element Method (FEM) to test the possibility that the Telamon could to support the weight of the upper portion of the temple. In this work the authors describe the 3D survey of Telamon carry out with Range-Based Modelling (RBM) and Image-Based Modeling (IBM). The RBM was performed with a TOF laser scanner while the IBM with the ZScan system of Menci Software and Image Master of Topcon. Several tests were conducted to analyze the accuracy of the different 3D models and to evaluate the difference between laser scanning and photogrammetric data. Moreover, an appropriate data reduction to generate a 3D model suitable for FEM analysis was tested.

  18. IMAGE-BASED AND RANGE-BASED 3D MODELLING OF ARCHAEOLOGICAL CULTURAL HERITAGE: THE TELAMON OF THE TEMPLE OF OLYMPIAN ZEUS IN AGRIGENTO (ITALY

    Directory of Open Access Journals (Sweden)

    M. Lo Brutto

    2012-09-01

    Full Text Available The Temple of Olympian Zeus in Agrigento (Italy was one of the largest temple and at the same time one of the most original of all the Greek architecture. We don’t know exactly how it was because the temple is now almost completely destroyed but it is very well-known for the presence of the Telamons. The Telamons were giant statues (about 8 meters high probably located outside the temple to fill the interval between the columns. In accordance with the theory most accredited by archaeologists the Telamons were a decorative element and also a support for the structure. However, this hypothesis has never been scientifically proven. One Telamon has been reassembled and is shown at the Archaeological Museum of Agrigento. In 2009 a group of researchers at the University of Palermo has begun a study to test the hypothesis that the Telamons support the weight of the upper part of the temple. The study consists of a 3D survey of the Telamon, to reconstruct a detailed 3D digital model, and of a structural analysis with the Finite Element Method (FEM to test the possibility that the Telamon could to support the weight of the upper portion of the temple. In this work the authors describe the 3D survey of Telamon carry out with Range-Based Modelling (RBM and Image-Based Modeling (IBM. The RBM was performed with a TOF laser scanner while the IBM with the ZScan system of Menci Software and Image Master of Topcon. Several tests were conducted to analyze the accuracy of the different 3D models and to evaluate the difference between laser scanning and photogrammetric data. Moreover, an appropriate data reduction to generate a 3D model suitable for FEM analysis was tested.

  19. Modeling LCD displays with local backlight dimming for image quality assessment

    Science.gov (United States)

    Korhonen, Jari; Burini, Nino; Forchhammer, Søren; Pedersen, Jesper M.

    2011-01-01

    Traditionally, algorithm-based (objective) image and video quality assessment methods operate with the numerical presentation of the signal, and they do not take the characteristics of the actual output device into account. This is a reasonable approach, when quality assessment is needed for evaluating the signal quality distortion related directly to digital signal processing, such as compression. However, the physical characteristics of the display device also pose a significant impact on the overall perception. In order to facilitate image quality assessment on modern liquid crystaldisplays (LCD) using light emitting diode (LED) backlight with local dimming, we present the essential considerations and guidelines for modeling the characteristics of displays with high dynamic range (HDR) and locally adjustable backlight segments. The representation of the image generated by the model can be assessed using the traditional objective metrics, and therefore the proposed approach is useful for assessing the performance of different backlight dimming algorithms in terms of resulting quality and power consumption in a simulated environment. We have implemented the proposed model in C++ and compared the visual results produced by the model against respective images displayed on a real display with locally controlled backlight units.

  20. Adaptive error detection for HDR/PDR brachytherapy: Guidance for decision making during real-time in vivo point dosimetry

    DEFF Research Database (Denmark)

    Kertzscher Schwencke, Gustavo Adolfo Vladimir; Andersen, Claus E.; Tanderup, Kari

    2014-01-01

    Purpose:This study presents an adaptive error detection algorithm (AEDA) for real-timein vivo point dosimetry during high dose rate (HDR) or pulsed dose rate (PDR) brachytherapy (BT) where the error identification, in contrast to existing approaches, does not depend on an a priori reconstruction...... of the dosimeter position. Instead, the treatment is judged based on dose rate comparisons between measurements and calculations of the most viable dosimeter position provided by the AEDA in a data driven approach. As a result, the AEDA compensates for false error cases related to systematic effects...... of the dosimeter position reconstruction. Given its nearly exclusive dependence on stable dosimeter positioning, the AEDA allows for a substantially simplified and time efficient real-time in vivo BT dosimetry implementation. Methods:In the event of a measured potential treatment error, the AEDA proposes the most...

  1. Multilayer optics for monochromatic high-resolution X-ray imaging diagnostic in a broad photon energy range from 2 keV to 22 keV

    Energy Technology Data Exchange (ETDEWEB)

    Troussel, Ph., E-mail: philippe.troussel@cea.fr [CEA, DAM, DIF, F-91297 Arpajon (France); Dennetiere, D. [Synchrotron Soleil, L’orme des Merisiers, 91190 Saint-Aubin (France); Maroni, R. [CEA, DAM, DIF, F-91297 Arpajon (France); Høghøj, P.; Hedacq, S. [Xenocs SA, 19, rue François Blumet, F-38360 Sassenage (France); Cibik, L.; Krumrey, M. [Physikalisch-Technische Bundesanstalt (PTB), Abbestr. 2-12, 10587 Berlin (Germany)

    2014-12-11

    The “Commissariat à l’énergie atomique et aux énergies alternatives” (CEA) studies and designs advanced X-ray diagnostics to probe dense plasmas produced at the future Laser MegaJoule (LMJ) facility. Mainly for X-ray imaging with high spatial resolution, different types of multilayer mirrors were developed to provide broadband X-ray reflectance at grazing incidence. These coatings are deposited on two toroidal mirror substrates that are then mounted into a Wolter-type geometry (working at a grazing angle of 0.45°) to realize an X-ray microscope. Non-periodic (depth graded) W/Si multilayer can be used in the broad photon energy range from 2 keV to 22 keV. A third flat mirror can be added for the spectral selection of the microscope. This mirror is coated with a Mo/Si multilayer for which the d-spacing varies in the longitudinal direction to satisfy the Bragg condition within the angular acceptance of the microscope and also to compensate the angular dispersion due to the field of the microscope. We present a study of such a so-called Göbel mirror which was optimized for photon energy of 10.35 keV. The three mirrors were coated using magnetron sputtering technology by Xenocs SA. The reflectance in the entire photon energy range was determined in the laboratory of the Physikalisch-Technische Bundesanstalt (PTB) at the synchrotron radiation facility BESSY II in Berlin.

  2. On the use of HDR Co60 source with the MammoSite(®) Radiation Therapy System.

    Science.gov (United States)

    Baltas, D; Lymperopoulou, G; Zamboglou, N

    2008-12-01

    This work summarizes Monte Carlo results in order to evaluate the potential of using HDR Co60 sources in accelerated partial breast irradiation (APBI) with the MammoSite(®) applicator. Simulations have been performed using the MCNP5 Monte Carlo Code, in simple geometries comprised of two concentric spheres; the internal consisting of selected concentrations, C, of a radiographic contrast solution in water (Omnipaque 300(™) ) to simulate the MammoSite balloon and the external consisting of water to simulate surrounding tissue. The magnitude of the perturbation of delivered dose due to the radiographic contrast medium used in the MammoSite(®) applicator is calculated. At the very close vicinity of the balloon surface, a dose build-up region is observed, which leads to a dose overestimation by the treatment planning system (TPS) which depends on Omnipaque(™) 300 solution concentration (and is in order of 2.3%, 3.0%, and 4.5%, respectively, at 1 mm away from the balloon - water interface, for C=10%, 15%, and 20%). However, dose overestimation by the TPS is minimal for points lying at the prescription distance (d=1 cm) or beyond, for all simulated concentrations and radii of MammoSite(®) balloon. An analytical estimation of the integral dose outside the CTV in the simple geometries simulated shows that dose to the breast for MammoSite(®) applications is expected to be comparable using HDR Co60 and Ir192 sources, and higher than that for Yb169. The higher enegies of Co60 sources result to approximately twice radiation protection requirements as compared to Ir169 sources. However, they allow for more accurate dosimetry calculation with currently used treatment planning algorithms for Co60 sources, compared to Ir169. © 2008 American Association of Physicists in Medicine.

  3. TU-AB-201-04: Optimizing the Number of Catheter Implants and Their Tracks for Prostate HDR Brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Riofrio, D; Luan, S [University of New Mexico, Albuquerque, New Mexico (United States); Zhou, J [William Beaumont Hospital, Royal Oak, MI (United States); Ma, L [UCSF Comprehensive Cancer Center, San Francisco, CA (United States)

    2015-06-15

    Purpose: In prostate HDR brachytherapy, interstitial implants are placed manually on the fly. The aim for this research is to develop a computer algorithm to find optimal and reliable implant trajectories using minimal number of implants. Methods: Our new algorithm mainly uses these key ideas: (1) positive charged static particles are uniformly placed on the surface of prostate and critical structures such as urethra, bladder, and rectum. (2) Positive charged kinetic particles are placed at a cross-section of the prostate with an initial velocity parallel to the principal implant direction. (3) The kinetic particles move through the prostate, interacting with each other, spreading out, while staying away from the prostate surface and critical structures. The initial velocity ensures that the trajectories observe the curvature constraints of typical implant procedures. (4) The finial trajectories of kinetic particles are smoothed using a third-degree polynomial regression, which become the implant trajectories. (5) The dwelling times and final dose distribution are calculated using least-distance programming. Results: (1) We experimented with previously treated cases. Our plan achieves all prescription goals while reducing the number of implants by 41%! Our plan also has less uniform target dose, which implies a higher dose is delivered to the prostate. (2) We expect future implant procedures will be performed under the guidance of such pre-calculated trajectories. To assess the applicability, we randomly perturb the tracks to mimic the manual implant errors. Our studies showed the impact of these perturbations are negligible, which is compensated by the least distance programming. Conclusions: We developed a new inverse planning system for prostate HDR therapy that can find optimal implant trajectories while minimizing the number of implants. For future work, we plan to integrate our new inverse planning system with an existing needle tracking system.

  4. Precipitable water and surface humidity over global oceans from special sensor microwave imager and European Center for Medium Range Weather Forecasts

    Science.gov (United States)

    Liu, W. T.; Tang, Wenqing; Wentz, Frank J.

    1992-01-01

    Global fields of precipitable water W from the special sensor microwave imager were compared with those from the European Center for Medium Range Weather Forecasts (ECMWF) model. They agree over most ocean areas; both data sets capture the two annual cycles examined and the interannual anomalies during an ENSO episode. They show significant differences in the dry air masses over the eastern tropical-subtropical oceans, particularly in the Southern Hemisphere. In these regions, comparisons with radiosonde data indicate that overestimation by the ECMWF model accounts for a large part of the differences. As a check on the W differences, surface-level specific humidity Q derived from W, using a statistical relation, was compared with Q from the ECMWF model. The differences in Q were found to be consistent with the differences in W, indirectly validating the Q-W relation. In both W and Q, SSMI was able to discern clearly the equatorial extension of the tongues of dry air in the eastern tropical ocean, while both ECMWF and climatological fields have reduced spatial gradients and weaker intensity.

  5. Response