WorldWideScience

Sample records for radon remedial methods

  1. Long term performance of different radon remedial methods in Sweden

    CERN Document Server

    Clavensjoe, B

    2002-01-01

    The object of this project was to investigate the long time effectiveness of different radon remedial methods. The ten years project started 1991. From start the investigation comprised of 105 dwellings (91 single-family houses and 14 flats in multi-family buildings). In all of the dwellings remedial measures were carried out in the eighties. Before and immediately after the reduction the local measured the radon concentrations. New measurements of the radon concentrations have been made every third year; in 1991, 1994, 1997 and in 2000. Twelve different radon remedial methods and method combinations were used. The radon sources were building materials as well as sub-soils. In all of the dwellings the radon concentrations were measured by nuclear track films during 3 months (January-March) measurements and in half of them the air change rates by passive tracer gas methods. The results of the 2000 and the 1991 (within brackets) studies showed that the radon concentration was up to 200 Bq/m sup 3 in 54 (54) sin...

  2. Methods of radon remediation in Finnish dwellings; Asuntojen radonkorjauksen menetelmaet

    Energy Technology Data Exchange (ETDEWEB)

    Arvela, H.

    1995-12-01

    A study was made of remedial measures taken in dwellings with high indoor radon concentrations and the results obtained. The data regarding the remedial measures taken in 400 dwellings was obtained from a questionnaire study. The mean annual average indoor radon concentration before the remedies was 1.500 Bq/m{sup 3}, the concentration exceeding in nearly every house the action level of 400 Bq/m{sup 3}. After the measures were taken the mean indoor radon concentration was 500 Bq/m{sup 3}. The resulting indoor radon concentration was less than 400 Bq/m{sup 3} in 60 percent of the dwellings. The best results were achieved using sub-slab-suction and radon well. These methods effectively decrease both the flow of radon bearing air from soil into dwellings and the radon concentration of leakage air. Typical reduction rates in radon concentration were 70-95 percent. The action level was achieved in more than 70 percent of the houses. Sealing the entry routes and improvement of the ventilation resulted typically in reduction rates of 10-50 percent. The goal of the report is to give useful information for the house owners, the do-it-yourself-mitigators, the mitigation firms and the local authorities. The report includes practical guidance, price information and examples of remedial measures. (13 refs., 10 figs., 2 tabs.).

  3. Long term performance of different radon remedial methods in Sweden

    International Nuclear Information System (INIS)

    Clavensjoe, Bertil

    2002-06-01

    The object of this project was to investigate the long time effectiveness of different radon remedial methods. The ten years project started 1991. From start the investigation comprised of 105 dwellings (91 single-family houses and 14 flats in multi-family buildings). In all of the dwellings remedial measures were carried out in the eighties. Before and immediately after the reduction the local authorities measured the radon concentrations. New measurements of the radon concentrations have been made every third year; in 1991, 1994, 1997 and in 2000. Twelve different radon remedial methods and method combinations were used. The radon sources were building materials as well as sub-soils. In all of the dwellings the radon concentrations were measured by nuclear track films during 3 months (January-March) measurements and in half of them the air change rates by passive tracer gas methods. The results of the 2000 and the 1991 (within brackets) studies showed that the radon concentration was up to 200 Bq/m 3 in 54 (54) single-family houses and 7 (7) flats, between 210 Bq/m 3 and 400 Bq/m 3 in 23 (18) single-family houses and 5 (6) flats, and higher than 400 Bq/m 3 in 12 (18) single-family houses and 2 (1) flats. The study 1991 showed also that in about 40 % of the cases the radon concentration had increased by more than 30 % only a few years after reduction actions had been taken. In 19 dwellings the radon concentration was at least doubled. In no fewer than 38 dwellings the radon level has been over 400 Bq/m 3 in at least one of the four measuring occasions. The change in radon concentrations was not specific to any given method but seemed to be evenly distributed over all of them. The investigation results showed the necessity for repeated measuring where counter measures have been taken. The causes for increasing radon levels have been made clear in all except 2-3 cases

  4. Radon in indoor air. Health risk, measurement methods and remedial measures

    International Nuclear Information System (INIS)

    Strand, T.

    1996-02-01

    Radon in indoor air is the main source of ionizing radiation in Norway. The booklet contains a presentation of radon sources, measurement methods, indoor radon concentrations, action levels, health risk and remedial measures

  5. Radon remediation in irish schools

    International Nuclear Information System (INIS)

    Synnott, H.

    2006-01-01

    Full text: Commencing in 1998, the Radiological Protection Institute of Ireland carried out radon measurements in 3826 schools in the Republic of I reland on behalf of the Irish Department of Education and Science (D.E.S.). This represents approximately 97% of all schools in the country. Approximately 25% (984) schools had radon concentrations above the Irish national schools Reference Level for radon of 200 Bq/m 3 and required remedial work. The number of individual rooms with radon concentrations above 200 Bq/m 3 was 3020. Remedial work in schools commenced in early 2000. In general schools with maximum radon concentrations in the range 200 -400 Bq/m 3 in one or more rooms were remediated through the installation of passive systems such as an increase in permanent background ventilation mainly wall vents and trickle vents in windows. Schools with maximum radon concentrations greater than 400 Bq/m 3 were usually remediated through the provision of active systems mainly fan assisted sub -slab de pressurization or where this was not possible fan assisted under floor ventilation. The cost of the remedial programme was funded by central Government. Active systems were installed by specialized remedial contractors working to the specifications of a radon remedial expert appointed by the D.E.S. to design remedial systems for affected schools. Schools requiring increased ventilation were granted aided 190 pounds per affected room and had to organize the work themselves. In most schools radon remediation was successful in reducing existing radon concentrations to below the Reference Level. Average radon concentration reduction factors for sub-slab de pressurization systems and fan assisted fan assisted under floor ventilation ranged from 5 to 40 with greater reduction rates found at higher original radon concentrations. Increasing ventilation in locations with moderately elevated radon concentrations (200 - 400 Bq/m 3 ) while not as effective as active systems produced on

  6. Reasons for increasing radon concentrations in radon remediated houses

    International Nuclear Information System (INIS)

    Clavensjoe, B.

    1997-01-01

    The study comprises 31 single-dwelling houses where remedial actions were carried out in the 1980s. In all of them the radon concentrations have increased more than 30% according to recent control measurements. Radon sources are building material as well as the soil. The remedial actions dealt with ventilation systems, leakage through the basement floor, air cushions, sub-slab suction or radon wells according to the original problems. Causes for the increase varied: In many houses with soil radon problems, the installation of a normal mechanical ventilation system is not a good remedial action. In some houses on a ground with high permeability and high radon content in the soil air, the radon concentration may increase by the lowering of the indoor air pressure. In other houses the increase was a measurement effect, where sites/rooms were confused. Living related causes were identified in a number of cases, where fan speeds were reduced for energy conservation/noise reduction purposes or different use of windows airing had occurred. Extension of the dwelling space without changing the ventilation system caused the increase in one house. 23 refs

  7. The principles of radon remediation and protection in UK dwellings

    International Nuclear Information System (INIS)

    Woolliscroft, M.

    1992-01-01

    This paper describes the principles of radon remediation and protection in UK dwellings. It states briefly why and how radon gets into dwellings and the main methods of remediation and protection; sealing, pressurisation, sub-floor ventilation, sub-floor depressurisation and, more problematically, ventilation of the dwelling. It goes on to discuss the effectiveness of the methods and why some methods are more or less effective than others. Data is presented on the effectiveness of protection in new dwellings. Solutions for existing dwellings are discussed and the remaining issues which are the subject of ongoing research are described. It is concluded that in general radon protection and remediation in new and the great majority of existing dwellings can be achieved simply and cheaply. (Author)

  8. Systematic effects in radon mitigation by sump/pump remediation

    International Nuclear Information System (INIS)

    Groves-Kirkby, C.J.; Denman, A.R.; Groves-Kirkby, C.J.; Woolridge, A.C.; Woolridge, A.C.; Phillips, P.S.; Crockett, R.G.M.; Tornberg, R.

    2006-01-01

    Sump/Pump remediation is widely used in the United Kingdom to mitigate indoor radon gas levels in residential properties. To quantify the effectiveness of this technology, a study was made of radon concentration data from a set of 173 homes situated in radon Affected Areas in and around Northamptonshire, U.K., re-mediated using conventional sump/pump technology. This approach is characterised by a high incidence of satisfactory mitigation outcomes, with more than 75% of the sample exhibiting mitigation factors (defined as the ratio of radon concentrations following and prior to remediation) of 0.2 or better. There is evidence of a systematic trend, where houses with higher initial radon concentrations have higher mitigation factors, suggesting that the total indoor radon concentration within a dwelling can be represented by two components, one susceptible to mitigation by sump/pump remediation, the other remaining essentially unaffected by these remediation strategies. The first component can be identified with ground-radon emanating from the subsoil and bedrock geologies, percolating through the foundations of the dwelling as a component of the soil-gas, potentially capable of being attenuated by sump/pump or radon-barrier remediation. The second contribution is attributed to radon emanating from materials used in the construction of the dwelling, principally concrete and gypsum plaster-board, with a further small contribution from the natural background level, and is essentially unaffected by ground-level remediation strategies. Modelling of such a two-component radon dependency using realistic ground-radon attenuation factors in conjunction with typical structural-radon levels yields behaviour in good agreement with the observed inverse-power dependence of mitigation factor on initial radon concentration. (authors)

  9. Remedial measures in Swedish and Norwegian houses - application of radon and radon decay product measurements

    International Nuclear Information System (INIS)

    Just, G.; Philipsborn, H. von; Matolin, M.; Molzahn, D.

    1998-01-01

    Houses and apartments in Sweden and Norway with excessive indoor radon concentrations were studied in detail with a variety of methods, standard and novel ones recently developed. For suitable remediation it is necessary to distinguish soil radon and exhalation from blue (porous) concrete. Our CARBOTEST-S is a simple, sensitive, in-situ method to quantify radon exhalation from existing walls, as well as radon permeability of different protective foils and final quality control of foils applied to existing walls. (orig.) [de

  10. Cost-effectiveness analysis of radon remediation in schools

    International Nuclear Information System (INIS)

    Kennedy, C.A.; Gray, A.M.

    2000-01-01

    Indoor radon is an important source of radiation dosage in the general population and has been recognised as a world-wide environmental and public health challenge. Governments in many Western and Eastern European and North American countries are undertaking active radon-risk reduction policies, including the remediation of existing residential and work place building stocks (1). These endeavours include a priority of remediating school buildings. Epidemiological and technical radon research has produced information which has enabled attention to be turned to specific effectiveness and optimisation questions regarding radon identification and remediation programmes in buildings, including schools. Decision making about policy implementation has been an integral part of these programmes and questions have been raised about the economic implications of the regulations and optimisation strategies for workplace action level policy (2,3). (the action level applied to schools is 400 Bq m -3 ). No previous study has estimated the cost-effectiveness of a radon remediation programme for schools using the methodological framework now considered appropriate in the economic evaluation of health interventions. It is imperative that this should be done, in order that the resources required to obtain health gain from radon remediation in schools can be systematically compared with equivalent data for other health interventions and radon remediation programmes. In this study a cost-effectiveness analysis of radon remediation in schools was undertaken, using the best available national data and information from Northamptonshire on the costs and effectiveness of radon identification and remediation in schools, and the costs and health impact of lung cancer cases. A model based on data from Northamptonshire is presented (where 6.3% of residential stock is over 200 Bq m -3 ). The resultant cost-effectiveness ratio was pound 7,550 per life year gained in pound 1997. Results from the

  11. Radon remediation of a two-storey UK dwelling by active sub-slab depressurization: observations on hourly Radon concentration variations

    International Nuclear Information System (INIS)

    Denman, A.R.

    2008-01-01

    Radon concentration levels in a two-storey detached single-family dwelling in Northamptonshire, UK, were monitored at hourly intervals throughout a 5-week period during which sub-slab depressurization remediation measures, including an active sump system, were installed. Remediation of the property was accomplished successfully, with the mean radon levels upstairs and downstairs greatly reduced and the prominent diurnal variability in radon levels present prior to remediation almost completely removed. Following remediation, upstairs and downstairs radon concentrations were 32% and 16% of their pre-remediation values respectively. The mean downstairs radon concentration was lower than that upstairs, with pre-and post-remediation values of the upstairs/downstairs concentration ratio, R U/D , of 0.93 and 1.76 respectively. Cross-correlation between upstairs and downstairs radon concentration time-series indicates a time-lag of the order of 1 hour or less, suggesting that diffusion of soil-derived radon from downstairs to upstairs either occurs within that time frame or forms a relatively insignificant contribution to the upstairs radon level. Cross-correlation between radon concentration time-series and the corresponding time-series for local atmospheric parameters demonstrated correlation between radon concentrations and internal/external pressure-difference prior to remediation. This correlation disappears following remediation, confirming the effectiveness of the remediation procedure in mitigating radon ingress from the ground via the stack-effect. Overall, these observations provide further evidence that radon emanation from building materials makes a not insignificant contribution to radon concentration levels within the building. Furthermore, since this component remains essentially unaffected by sub-slab depressurization, its proportional contribution to the total radon levels in the home increases following remediation, leading to the conclusion that where

  12. Radon impact at a remediated uranium mine site in Japan

    International Nuclear Information System (INIS)

    Ishimori, Yuu

    2011-01-01

    This paper mainly illustrates the radon impact of the closed uranium mine site remediated in 2007. The site remediated is the waste rock site located on the steep slope of a hill about 1.5 km upstream from a residential area along a main ravine. Major remedial action was to cover these waste rock yards with weathering granite soil. The radon flux density after remediation was intended to be 0.1 Bqm -2 s -1 in consideration with the natural background level around Ningyo-toge because there is no value of radon flux density regulated in Japan. Our action decreased the radon concentration in the site to natural background level, approximately from 10 to 40 Bqm -3 , although relatively high concentration in excess of 100 Bqm -3 was observed before remediation. On the other hand, our action did not decrease the radon concentrations around the site in general. This fact proved that the limited source such as waste rocks affected the radon concentrations at neighboring area only. The similar tendencies were also observed in other environmental data such as radon progeny concentrations. In conclusion, these findings proved that our remedial action was successful against radon. This fact will lead to more reasonable action plans for other closed mine sites. (author)

  13. Radon remedial measures in cold climate

    International Nuclear Information System (INIS)

    Birovljev, A.

    2004-01-01

    A view is taken that mitigation of an indoor radon problem is often more complex than usually assumed, and that additional factors should be considered to avoid situations in which after mitigation the radon problem may be solved, but other problems have been created. Emphasis is put on how the choice and design of radon remedial measures are influenced not only by effectiveness in reducing radon levels indoors, but also by climatic factors, energy-saving aspects, as well as economic and psycho-social factors. Climatic conditions give rise to several concerns when attempting to mitigate a radon problem in areas with large seasonal temperature variations. Problems with humidity, energy consumption and durability of sealing materials are probably the most prominent issues. Commonly used radon remedial measures and their effectiveness in Norway is reviewed. Discussion is focused on principles and technical solutions which produce good results, and those which don't perform so well in cold Norwegian climate. Innovative technical solutions which successfully resolve some of the main conflicting issues are discussed. Results of some preliminary tests showing performance of such solutions in reduction of radon levels are presented. Other aspects of mitigation systems, such as need and cost of maintenance, longevity, noise levels, 'additional benefits', etc., are briefly mentioned. Homeowners' perceptions and willingness to implement various mitigation solutions are briefly reviewed. Based on discussion, several guiding principles which may be adopted in search for optimal solutions are suggested. (author)

  14. Procedure manual for the estimation of average indoor radon-daughter concentrations using the radon grab-sampling method

    International Nuclear Information System (INIS)

    George, J.L.

    1986-04-01

    The US Department of Energy (DOE) Office of Remedial Action and Waste Technology established the Technical Measurements Center to provide standardization, calibration, comparability, verification of data, quality assurance, and cost-effectiveness for the measurement requirements of DOE remedial action programs. One of the remedial-action measurement needs is the estimation of average indoor radon-daughter concentration. One method for accomplishing such estimations in support of DOE remedial action programs is the radon grab-sampling method. This manual describes procedures for radon grab sampling, with the application specifically directed to the estimation of average indoor radon-daughter concentration (RDC) in highly ventilated structures. This particular application of the measurement method is for cases where RDC estimates derived from long-term integrated measurements under occupied conditions are below the standard and where the structure being evaluated is considered to be highly ventilated. The radon grab-sampling method requires that sampling be conducted under standard maximized conditions. Briefly, the procedure for radon grab sampling involves the following steps: selection of sampling and counting equipment; sample acquisition and processing, including data reduction; calibration of equipment, including provisions to correct for pressure effects when sampling at various elevations; and incorporation of quality-control and assurance measures. This manual describes each of the above steps in detail and presents an example of a step-by-step radon grab-sampling procedure using a scintillation cell

  15. Radon in the workplace: Implications of studies of post-remediation monitoring

    International Nuclear Information System (INIS)

    Denman, A. R.; Parkinson, S.; Johnstone, M.; Crockett, R. G. M.; Phillips, P. S.

    2004-01-01

    Radon gas has been shown to cause an increased incidence of lung cancer. In affected areas, levels in the overground workplace can be sufficiently high to be a health risk and remediation is required. In the UK, the workplace Action Level is 400 Bq m -3 . The variation of radon levels in the workplace was studied both before and after remediation. In most rooms, remediation resulted in a greater reduction at night than during the working day. The dose reduction, and therefore the health benefit, to workers is less than that predicted by the drop in radon averaged over 24 h. In order to obtain a health benefit to 75% of workers in our series, the 24 h average radon level in each room must be reduced to -3 . It is recommended that UK Regulatory Agencies adopt a post-remediation workplace Action Level of 225 Bq m -3 . (authors)

  16. The efficacy and durability of radon remedial measures

    International Nuclear Information System (INIS)

    Cliff, K.D.; Naismith, S.P.; Scivyer, C.; Stephen, R.

    1994-01-01

    In the UK, over 16,000 homes, from an estimated 100,000, with annual average radon concentrations exceeding the UK Action Level of 200 Bq.m -3 have been discovered. Some 600 householders who have taken action have sought confirmatory measurements from NRPB. Results for 345 such homes are discussed. A number of remedied homes are being remeasured annually to determine the durability of the remedies: results for the first year follow-up measurements are given. In a separate exercise, homes having the highest radon levels known in the UK have been enrolled in a research programme of the Building Research Establishment. The results for 53 homes in which BRE surveyed, designed and supervised remedial work are presented. (author)

  17. Radon remedial actions in schools of Friuli Venezia Giulia region (NE Italy)

    International Nuclear Information System (INIS)

    Giovani, C.; Cappelletto, C.; Garavaglia, M.; Pividore, S.; Villalta, R.

    2004-01-01

    In the last four years the Regional Agency of Environmental Protection (ARPA) of Friuli Venezia Giulia carried out a survey to determine the radon concentration in the schools of the area. During the survey all the 1320 schools and kindergartens of the region were investigated with more than 5000 measurements. In about 2% of cases, radon concentrations exceeded the reference levels of Italian law and remedial actions were performed. In collaboration with the Building Engineering Department of Udine University, ARPA FVG edited a manual concerning indications and proposals for building protection against radon. The environmental physics section of ARPA FVG, was heavily involved in the remedial action, both in the design of the action and in the investigation of effectiveness. In more than 20 schools the owners following ARPA indications solved the problem of high radon concentrations. In this paper the authors report the main type of applied remedial actions grouped taking into account the different remedial methodology. In Friuli Venezia Giulia region the main radon source is represented by soil. The contribution of building materials to high radon concentrations is negligible. The most common remedial actions consisted in natural or artificial depressurization of the soil or the crawlspace with respect to indoor building. Sometimes air was pumped into the building or air exchange number was increased. The authors show in detail the design of the performed investigations: these involved different measurement sets with passive electrets and active instruments for continuous data collection. Measurements usually last 3 contiguous weeks and are followed by long period measurements with solid track detectors. Optimization of remedial action performance was investigated when remedial action consisted in active air extraction from the soil under the buildings and fan time regulation was possible. Very often simple and cheap actions allowed a reduction of 90% in radon

  18. Analysis of the individual health benefits accruing from a domestic radon remediation programme

    International Nuclear Information System (INIS)

    Denman, A.R.; Phillips, P.S.; Tornberg, R.; Groves-Kirkby, C.J.

    2005-01-01

    Although radon can be present within buildings at sufficient levels to pose a health risk, levels can be reduced relatively easily. Recent studies on a group of radon-remediated homes, based on assessment of collective population-average risk coefficients, have estimated the benefits and cost effectiveness accruing from remediation and have confirmed that domestic remediation in UK radon Affected Areas would result in significantly reduced cancer risks to the population in those areas. Although the population-average approach used hitherto has applied occupancy and lung-cancer risk factors, these are potentially misleading in assessing discrete populations. The study reported here uses the recently developed European Community Radon Software (ECRS) to quantify individual risks in a sample of householders who remediated their homes following indications that radon levels exceeded the action level. The study proceeds from population-averaged to 'individual risk' evaluation, successfully comparing individual and collective risk assessments, and demonstrates that those who remediate are not representative of the general population. Health benefits accruing from remediation are three times lower than expected, largely because remediators are older, live in smaller households, and smoke less than the population average, leading to the conclusion that the current strategy employed in the UK is failing to target those most at risk

  19. The effectiveness of radon preventive and remedial measures in Irish homes

    International Nuclear Information System (INIS)

    Long, S; Fenton, D; Cremin, M; Morgan, A

    2013-01-01

    It is estimated that approximately 100 000 Irish homes have radon concentrations above the reference level of 200 Bq m −3 . To minimise the number of new homes with this problem, building regulations require that all new homes built since July 1998 in high radon areas are installed with radon barriers during construction. Measurements on local authority homes in a number of high radon areas have allowed the impact of these new regulations to be assessed. In County Cork a reduction of up to 70% in the mean radon concentration was observed in homes built since 1998 relative to those built before this date. A reduction in both the number of homes exceeding the reference level and the maximum concentration measured in homes was also measured. Homes exceeding the reference level were remediated with the use of an active sump. The results of this remedial work are also presented and show that the mean reduction in radon concentration achieved was 92%. (paper)

  20. Limited applicability of cost-effectiveness and cost-benefit analyses for the optimization of radon remedial measures

    International Nuclear Information System (INIS)

    Jiránek, Martin; Rovenská, Kateřina

    2010-01-01

    Ways of using different decision-aiding techniques for optimizing and evaluating radon remedial measures have been studied on a large set of data obtained from the remediation of 32 houses that had an original indoor radon concentration level above 1,000 Bq/m 3 (around 0.2 % of all dwellings in the Czech Republic have a radon concentration higher than 1,000 Bq/ m 3 ). Detailed information about radon concentrations before and after remediation, type and extent of remedial measures and installation and operation costs were used as the input parameters for a comparison of costs and for determining the efficiencies, for a cost-benefit analysis and a cost-effectiveness analysis, in order to find out whether these criteria and techniques provide sufficient and relevant information for the improvement and optimization of remediation. The study has delivered quite new results. It is confirmed that the installation costs of remedial measures do not depend on the original level of indoor radon concentration, but on the technical state of the building. In addition, the study reveals that the efficiency of remediation does not depend on the installation costs. Each of the studied remedial measures will on an average save 0.3 lives and gain 4.3 years of life. On one hand, the general decision-aiding techniques - cost-benefit analysis and cost-effectiveness analysis - lead to the conclusion that the remedial measures reducing the indoor radon concentration from values above 1,000 Bq/m 3 to values below the action level of 400 Bq/m 3 are always acceptable and reasonable. On the other hand, these analytical techniques can neither help the designer to choose the proper remedial measure nor provide information resulting in improved remediation. (author)

  1. Surveying dwellings with high indoor radon levels: a BRE guide to radon remedial measures in existing dwellings

    International Nuclear Information System (INIS)

    Scivyer, C.R.

    1993-01-01

    This report is one of a series giving practical advice on methods of reducing radom levels in existing dwellings. It is aimed specifically at builders, surveyors and building specialists surveying for and prescribing remedial measures for dwellings. It supplements guidance available in 'The householders' guide to radon, obtainable from local environmental health officers or from the Department of the Environment. (Author)

  2. An assessment of individual health benefits from a domestic Radon remediation programme

    International Nuclear Information System (INIS)

    Denman, A.R.; Phillips, P.S.; McClatchey, J.

    2002-01-01

    Radon gas occurs naturally in the environment and has been shown to cause increased numbers of lung cancers in miners when present at high levels in underground workings. Reviews of the miners' studies suggest that levels found in some homes can give rise to increased lung cancer incidence, and this has been confirmed by recent case control studies in South West England, and Germany. The current scientific consensus, expressed in the BEIR 6. report is that the risk of lung cancer has a linear relation with increasing radon exposure, and that there is no threshold of risk. The distribution of such excessive levels is geographically varied, and many countries have established programmes to identify the homes at risk, and encourage homeowners to remediate to reduce levels. Northamptonshire, in the centre of England, has been declared a radon Affected Area by the National Radiological Protection Board (NRPB), and has an average of 6.3 % of homes above the UK domestic Action Level of 200 Bq m -3 . Several studies have suggested that theoretically such programmes can be justified on the basis of health benefits and cost effectiveness. Our group was the first to study actual radon remediation programmes - in Northamptonshire, studying first National Health Service properties, schools, and homes. These studies demonstrated that remediation programmes in Northamptonshire could be justified. The domestic radon remediation programme in Northamptonshire, once complete, could be favourably compared to other health initiatives such as the UK mammography screening programme for women aged 50 to 65

  3. Dwellings with cellars and basements. A BRE guide to radon remedial measures in existing dwellings

    International Nuclear Information System (INIS)

    Scivyer, C.R.; Jaggs, M.P.R.

    1998-01-01

    This guide is one of a series giving practical advice on methods of reducing radon levels in existing dwellings. It is intended to help surveyors, builders and householders who are trying to reduce indoor radon levels in houses with cellars or basements. The guide is based on a large body of remedial work carried out to advice given by BRE, and on discussions with others working in the field. The measures it describes are applicable, in principle, to all dwellings and other buildings of a similar scale and construction which have cellars or basements. Contact details of other organisations referred to are listed at the back of this guide. Basements and cellars are relatively uncommon in the United Kingdom, but where they do occur they are likely to be major contributors to the radon problem within a building. Experience shows that most houses with high indoor radon levels can be remedied through the use of straightforward building works. These can be carried out by a builder or householder competent in DIY. The cost should not be excessive. Before reading this guide, for background information on radon, consult Radon: a householder's guide and Radon: a guide to reducing levels M your home, obtainable from local Environmental Health Officers or from the Department of the Environment, Transport and the Regions. The Government recommends that, if the average radon concentration in a dwelling exceeds 200 Bq/m 3 (the 'action' level), measures should be taken to reduce it. This guide assumes that radon measurements have been made in the building and that the annual average indoor radon level was shown to exceed the action level

  4. A comparative review of the effectiveness of radon remediation programmes in hospitals, schools and homes in Northamptonshire, UK

    International Nuclear Information System (INIS)

    Denman, A.R.; Phillips, P.S.; Tornberg, R.

    2000-01-01

    In the UK, the National Radiological Protection Board (NRPB) has designated a number of Affected Areas where 1% or more of the homes are above the Action Level of 200 Bqm -3 , including Northamptonshire, with 6.3% of houses above the Action Level. Since 1993, a radon remediation programme in National Health Service properties in Northamptonshire has been undertaken (1). Radon levels both before and after remediation were studied, together with the number of occupants of affected rooms, and their pattern of occupation. The total costs were recorded, including the initial survey to find the affected rooms, and the work done to reduce radon levels, to estimate the total cost per annual dose saved. This method has been extended to domestic properties (2), and schools (3) in Northamptonshire. The results showed that the programmes could be justified when compared to the NRPB initiative to reduce patient dose from dental X-Rays. This paper reviews this work, and provides an updated comparison of the three studies. The domestic series now extends to 65 remediated homes with 156 occupants, and the analysis of the programme now includes the cost of UK Value Added Tax (VAT) at 17.5%, which is payable by the householder on the remediation work. Further, a local survey concluded that the public in county town of Northampton spent on average 72% of their time in their own home, rather than the 50% assumed previously. The remediation costs in all series were reviewed, and individual corrections made for inflation. While the NHS properties and Schools programmes were comprehensive, only 10% householders who discovered raised radon levels have so far proceeded to remediation, despite much local publicity. The collective dose saved annually in Northamptonshire was estimated to be 0.533 man-sieverts in NHS Properties, 4.0 man-sieverts in Schools, and has reached 18 man-sieverts in domestic properties. The domestic programme has the potential to save 690 man-sieverts if all houses

  5. A review of the factors affecting the cost effectiveness and health benefits of domestic radon remediation programmes

    International Nuclear Information System (INIS)

    Denman, A.R.; Phillips, P.S.; Crockett, R.G.M.

    2008-01-01

    Radon levels in domestic properties can be sufficiently high to pose a health hazard, significantly increasing the risk of lung cancer. The distribution of high levels varies geographically. As a result, radon remediation programmes in the United Kingdom (UK) have been developed, firstly to find the houses with high levels, and then remediate these. Our group has extensively studied domestic remediation programmes in the U.K., principally in Northamptonshire, where 6.3% of existing houses exhibit radon levels greater than the UK Action Level of 200 Bq.m -3 , but also in other parts of the country. This analysis has addressed the influences of a number of different factors. Firstly, programmes in areas where more houses are over the Action level are necessarily more cost-effective. Secondly, cost-effectiveness is reduced if people do not take action to test, and then remediate, their houses, which is the case in practice. Therefore, radon awareness programmes in areas with a modest number of houses over the Action level can be more expensive, and therefore inappropriate, compared with other health interventions. Our studies have also demonstrated that the occupancy of the home, together with the ratio of radon levels upstairs and downstairs, has only a modest effect on the value of remediation. More significantly, remediation with an active pump eliminates diurnal variation, and night-time exposure is thus reduced while day-time exposure is not. The most significant impact on the value of remediation programmes, however, is whether the occupants smoke, as radon and smoking combine to produce a greater health risk. Unfortunately, surveys have shown that fewer smokers take action to test and remediate their homes, and many of those most at risk are consequently not reached by the current programmes. This paper presents a review of these issues, and considers the impact of the results on the design of future remediation programmes. (author)

  6. Indoor radon in selected homes in Aburi Municipality: measurement uncertainty, decision analysis and remediation strategy

    International Nuclear Information System (INIS)

    Yeboah, M. S.

    2014-07-01

    The main source of natural internal irradiation of man is radon and its decay products. In this study, the radon concentration levels in selected homes in Aburi of the Akuapim North Municipal Assembly in Eastern Region, Ghana were estimated using time-intergrated passive radon detector; LR-115 Type II solid state nuclear track detector (SSNTD) technique. The primary objective of the study was to measure radon levels in 30 selected homes in the Aburi municipality and determine the uncertainties associated with the measured radon concentrations in order to take a decision on remedial actions to be adopted in case of any abnormality using simple qualitative decision analysis method. Measurements were carried out from December, 2013 to March, 2014. After each month of exposure for a period of three months, the detectors were subjected to chemical etching in a 2.5M analytical grade of sodium hydroxide solution at (60 ± I )OC, for 90mins in a constant temperature water bath to enlarge the latent tracks produced by alpha particles from the decay of radon. The etched tracks were magnified using the microfiche reader and counted with a tally counter. The results obtained from the study revealed that concentration of radon in most of the selected homes in the Aburi municipality is low and it is within the internationally accepted action level of 100Bqm-3 set by WHO (2009). The analysis of the results established that the average radon concentrations vary in the range 23.72- 92.24Bqm -3 , 19.07-124.36 Bqm -3 and 31.63-123.87 Bqm -3 for month I, month 2 and month 3 respectively. The corresponding mean values are 46.77, 45.92 and 56.66 Bqm -3 respectively with standard deviations of ±2.18. ±2.38 and ±2.76. These gave a mean of 49.78 ± 12.50 for the three months. Two (2) of the rooms investigated had values above 20 % of the remedial action level of 100Bqm -3 in two of the months but with their average values slightly lower than the remedial action level. From the

  7. Radon remediation of dwellings with suspended timber floors -case studies from the Building Research Establishment (UK)

    International Nuclear Information System (INIS)

    Welsh, P.; Stephen, R.

    1994-01-01

    Dwellings with suspended floors and high radon levels are proving difficult to remediate. This paper reports on the experience of the Building Research Establishment in dealing with such dwellings. Brief details of the remediation of 14 houses are given, and comparisons are made between the effectiveness of the different techniques adopted. Natural ventilation, mechanical supply ventilation and mechanical extract ventilation are three techniques that have been used successfully as radon remedial measures. Preliminary results suggest that supply ventilation is more effective than extract ventilation. (author)

  8. Surveying dwellings with high indoor radon levels: a BRE guide to remedial measures in existing dwellings

    International Nuclear Information System (INIS)

    Scivyer, C.R.

    1993-01-01

    This report is one of a series giving practical advice on methods of reducing radon levels in existing dwellings. It is aimed specifically at builders, surveyors and building specialists surveying for and prescribing remedial measures for dwellings. It supplements guidance available in The householders' guide to radon obtainable from local environmental health officers or from the Department of the Environment. The report has been prepared on the basis of experience gained in remedial work on more than 100 dwellings following advice given by BRE, and of discussions with others in the field, notably the National Radiological Protection Board (NRPB) and Cornwall County Council. Work is continuing, particularly dealing with suspended timber floors, basements and ventilation systems. Results will be incorporated into revisions of this report as they become available. (Author)

  9. Prevention of lung cancer by remediation of residential exposure to radon daughters

    International Nuclear Information System (INIS)

    Mahaffey, J.A.; Cross, F.T.; Johnson, J.R.; Baechler, M.C.

    1991-01-01

    The United States Bonneville Power Administration (BPA), as part of an energy conservation programme in the states of Washington, Oregon, Idaho, Wyoming, and Montana, has collected over 36,000 residential radon concentration measurements. Data were collected between 1983 and 1989 with ambient α etched track dosemeters. Based on the linear risk coefficient from the BEIR IV report for lifetime lung cancer in smokers and non-smokers, numbers of lung cancer cases attributable to radon exposure were predicted. Numbers of baseline lung cancer cases and numbers of these that were preventable by remediation were also estimated. Remediation to 10 pCi.1 -1 , to 4 pCi.1 -1 , and to outdoor levels were considered. With vital statistics data, results were extrapolated to populations in the states represented by the BPA data. Costs of remediation were estimated. Results were evaluated in terms of cost per cancer saved and per cent reduction in fatal lung cancer cases from the baseline estimate. (author)

  10. An evaluation of passive methods for measurement of radon in dwellings

    International Nuclear Information System (INIS)

    Strand, T.; Lind, B.; Kolstad, A.K.

    1989-01-01

    During the last ten years, different methods have been developed for the measurement of radon in indoor air. In this report the different methods in use by private firms in Norway have been compared. The results of the study show that the methods are quite different in regard to integration time, detection limit and reliability in measurements of radon in indoor air. In 1988 the National Institute of Radiation Hygiene gave directives on the performance of such measurements. In these directives, minimum limits have been set for integration time (7 days) for methods to be used in evaluations of remedial actions. In this report the results from a simple, anonymeous reliability test are reported. The test covered the private firms offering radon meassurement services in Norway. The frequently reported weaknesses by the charcoal method were confirmed in the study. The directives on radon measurements in dwellings are presented. 73 refs.; 11 figs.; 5 tabs

  11. A detailed evaluation of the individual health benefits arising in a domestic property following radon remediation - a case-study in Northamptonshire, U.K

    International Nuclear Information System (INIS)

    Denman, A.R.; Briggs, D.J.; Allison, C.C.; Groves-Kirkby, C.J.; Phillips, P.S.; Crockett, R.G.M.

    2008-01-01

    Radon gas occurs naturally in the environment with variable distribution, concentrating sufficiently in the built environment in some areas to pose a public health risk. Radon levels can be successfully reduced in affected buildings, and large-scale remediation programmes have been justified in terms of accrued costs and benefits. We present results from a house where radon levels in the main living-room and master bedroom were monitored on an hourly basis over extended periods before and after radon remediation by sub-slab depressurisation. These results were combined with results from a recent occupancy survey to estimate the health impact on occupants spending varying times in the home. Prior to remediation, mean hourly radon exposure is moderately linearly correlated (R 2 = 0.66-0.78) with time spent in the house. Following remediation, correlation is significantly enhanced (R 2 = 0.91-0.95), but the exposure reduction of an occupant following remediation is less than that predicted using the NRPB protocol

  12. A detailed evaluation of the individual health benefits arising in a domestic property following radon remediation - a case-study in Northamptonshire, U.K

    Energy Technology Data Exchange (ETDEWEB)

    Denman, A.R. [Medical Physics Department, Northampton General Hospital NHS Trust, Cliftonville, Northampton NN1 5BD (United Kingdom); School of Health, University of Northampton, Boughton Green Road, Northampton NN2 7AL (United Kingdom)], E-mail: tony.denman@northampton.ac.uk; Briggs, D.J. [Department of Epidemiology and Public Health, Imperial College of Science, Technology and Medicine, London W1 2PG (United Kingdom)], E-mail: d.briggs@imperial.ac.uk; Allison, C.C. [Medical Physics Department, Northampton General Hospital NHS Trust, Cliftonville, Northampton NN1 5BD (United Kingdom)], E-mail: claire.allison@ngh.nhs.uk; Groves-Kirkby, C.J. [Medical Physics Department, Northampton General Hospital NHS Trust, Cliftonville, Northampton NN1 5BD (United Kingdom)], E-mail: chris.groves-kirkby@ngh.nhs.uk; Phillips, P.S. [School of Applied Sciences, The University of Northampton, Boughton Green Road, Northampton NN2 7AL (United Kingdom)], E-mail: paul.phillips@northampton.ac.uk; Crockett, R.G.M. [School of Applied Sciences, University of Northampton, Boughton Green Road, Northampton NN2 7AL (United Kingdom)], E-mail: robin.crockett@northampton.ac.uk

    2008-07-15

    Radon gas occurs naturally in the environment with variable distribution, concentrating sufficiently in the built environment in some areas to pose a public health risk. Radon levels can be successfully reduced in affected buildings, and large-scale remediation programmes have been justified in terms of accrued costs and benefits. We present results from a house where radon levels in the main living-room and master bedroom were monitored on an hourly basis over extended periods before and after radon remediation by sub-slab depressurisation. These results were combined with results from a recent occupancy survey to estimate the health impact on occupants spending varying times in the home. Prior to remediation, mean hourly radon exposure is moderately linearly correlated (R{sup 2} = 0.66-0.78) with time spent in the house. Following remediation, correlation is significantly enhanced (R{sup 2} = 0.91-0.95), but the exposure reduction of an occupant following remediation is less than that predicted using the NRPB protocol.

  13. Temporal patterns of lung cancer risk from radon and smoking - consequences to remediation measures

    International Nuclear Information System (INIS)

    Tomasek, L.

    2004-01-01

    Studies of uranium miners conducted since the late 1960s demonstrated that the risk depends on cumulated exposure in terms of working level months (WLM) integrating both duration of exposure and concentration of radon. It has been also demonstrated that the risk from radon decreases with time since exposure. The present analysis of temporal changes of relative risk is based on a model where the total individual exposure is partitioned into components in dependence on time. Exposure to radon is studied in a cohort of 9411 Czech uranium miners with 766 cases of lung cancer and in a residential study of 11 803 inhabitants exposed to radon in houses with 218 cases. In addition, temporal patterns of the risk from smoking are analyzed in a case-control study of patients from a major Prague hospital including 566 cases. For both carcinogens, the relative risk decreases with time since exposure. The risk from exposures before 20-34 years is 36% and 34% in comparison to period 5-19 for smoking and radon, respectively. The effect of exposures from more distant periods 35-49 is only 5% for smoking and 14% for radon in comparison to 5-19 years. This substantial decrease of relative risk with time may contribute to a better evaluation of remediation measures taken in houses and in the cost effectiveness of remediation. Combined effect of smoking and radon is studied by a nested case-control approach including 434 cases and 962 controls. Analyses of the joint effects of smoking and radon, conducted in the occupational and the residential studies, suggest a sub-multiplicative interaction. The relative risk from radon among non-smokers is higher by a factor of 2-3 in comparison to smokers, suggesting different patterns of lung deposition and clearance among smokers and non-smokers. (author)

  14. Validation of the abbreviated Radon Progeny Integrating Sampling Unit (RPISU) method for Mesa County, Colorado

    International Nuclear Information System (INIS)

    Langner, G.H. Jr.

    1987-06-01

    The US Department of Energy (DOE) Office of Remedial Action and Waste Technology established the Technical Measurements Center at the DOE Grand Junction, Colorado, Projects Office to standardize, calibrate, and compare measurements made in support of DOE remedial action programs. Indoor radon-daughter concentration measurements are made to determine whether a structure is in need of remedial action. The Technical Measurements Center conducted this study to validate an abbreviated Radon Progeny Integrated Sampling Unit (RPISU) method of making indoor radon-daughter measurements to determine whether a structure has a radon-daughter concentration (RDC) below the levels specified in various program standards. The Technical Measurements Center established a criterion against which RDC measurements made using the RPISU sampling method are evaluated to determine if sampling can be terminated or whether further measurements are required. This abbreviated RPISU criterion was tested against 317 actual sets of RPISU data from measurements made over an eight-year period in Mesa County, Colorado. The data from each location were tested against a standard that was assumed to be the same as the actual annual average RDC from that location. At only two locations was the criterion found to fail. Using the abbreviated RPISU method, only 0.6% of locations sampled can be expected to be falsely indicated as having annual average RDC levels below a given standard

  15. Second workshop on radon and radon daughters in urban communities associated with uranium mining and processing

    International Nuclear Information System (INIS)

    1979-01-01

    A second meeting of Atomic Energy Control Board staff, federal and provincial government representatives, and consultants was held to discuss progress in reducing the concentrations of radon and its daughter products in houses in communities like Bancroft, Elliot Lake, Port Hope, and Uranium City. Participants discussed successful and unsuccessful remedial techniques, possible sources of radon, and methods of measuring radon and radon daughters in buildings

  16. New Jersey's residential radon remediation program - methods and experience

    International Nuclear Information System (INIS)

    Pluta, T.A.; Cosolita, F.J.; Rothfuss, E.

    1986-01-01

    As part of a remedial action program to decontaminate over 200 residential properties, 12 typical properties were selected and a demonstration program was initiated in the spring of 1985. The residences selected represented a range of contamination levels and configurations and differing architectural styles representative of the age of construction. The physical limitations of the sites and the overall nature of a decontamination project in active residential communities imposed a number of severe restrictions on work methods and equipment. Regulations governing transportation and disposal set virtually zero defect standards for the condition of containers. The intrusive nature of the work in residential neighborhoods required continual interaction with local residents, public officials and citizen task forces. Media coverage was very high. Numerous briefings were held to allay fears and promote public understanding. Numerous issues ranging in content from public health and safety to engineering and construction methods arose during the remedial action program. These issues were resolved by a multi-disciplined management team which was knowledgeable in public administration, radiation physics, and engineering design and construction. This paper discusses the nature of the problem, the methods applied to resolve the problem and the experience gained as a result of a remedial action program

  17. Third workshop on radon and radon daughters in urban communities associated with uranium mining and processing. Pt. 1

    International Nuclear Information System (INIS)

    1980-01-01

    This third meeting of Atomic Energy Control Board staff, contractors, federal and provincial government representatives, and delegates from outside Canada was held to discuss progress in reducing concentrations of radon and radon daughters in houses. Speakers talked about successful and unsuccessful remedial measures, methods of measuring and monitoring thoron and radon in houses, and indoor radon concentrations in Canada, Britain and Sweden

  18. Workshop on radon and radon daughters in urban communities associated with uranium mining and processing

    International Nuclear Information System (INIS)

    1978-01-01

    This meeting of Atomic Energy Control Board staff, representatives of other government departments, and consultants was called to exchange information on steps taken to lower radiation levels in houses in communities such as Elliot Lake, Uranium City, and Port Hope. Discussions covered the sources of radon and radon daughters in these houses, radon measurement techniques, and remedial methods that worked or were not successful

  19. Radon-technical design methods based on radon classification of the soil

    International Nuclear Information System (INIS)

    Kettunen, A.V.

    1993-01-01

    Radon-technical classification of the foundation soil divides the foundation soil into four classes: negligible, normal, high and very high. Separate radon-technical designing methods and radon-technical solutions have been developed for each class. On regions of negligible class, no specific radon-technical designing methods are needed. On regions of normal radon class, there is no need for actual radon-technical designing based on calculations, whereas existing radon-technical solutions can be used. On regions of high and very high radon class, a separate radon-technical designing should be performed in each case, where radon-technical solutions are designed so that expected value for indoor radon content is lower than the maximum allowable radon content. (orig.). (3 refs., 2 figs., 2 tabs.)

  20. Radon

    International Nuclear Information System (INIS)

    1990-01-01

    This leaflet in the At-a-Glance Series, describes what radon is, where it is found, why it presents a risk to health, the official advice, and the remedies that are available to reduce radon levels. (author)

  1. An assessment of the health benefits of radon mitigation of buildings in radon affected areas

    International Nuclear Information System (INIS)

    Denman, A.R.

    1999-06-01

    Excessive concentrations of radon are known to cause lung cancers in miners, but it is only recently that evidence has accumulated that raised radon levels in the built environment may also be a risk. It is possible to reduce such levels, and so efforts have continued to locate affected areas both in the United Kingdom, and elsewhere. Northamptonshire was declared a Radon Affected Area in 1992. As Radiation Protection Adviser, 1 initiated routine radon surveys of all National Health Services (NHS) premises in Northamptonshire. It was clear from the literature that no major workplace study had been published. This started a programme of published research, which forms the basis of this Ph.D. submission. The research remains the only body of published results of actual remediation programmes. The research programme first estimated doses to occupants in affected rooms, and showed that individual doses were higher, and the number of staff affected greater, than staff exposure during the clinical use of X-Rays in the same hospitals. The costs of remediation of each affected room, together with measurements of radon levels afterwards, were recorded, permitting the first analysis of the costs and benefits of an actual remediation programme. Only predicted costs of proposed domestic remediation programmes had been published, and it was shown that remediation in the NHS workplace was more costly than these predictions, but still comparable with the National Radiological Protection Board (NRPB) initiative to reduce patient dose from dental X-Rays. The work was then extended to remediation programmes in schools and houses in Northamptonshire, permitting the first published comparison of such programmes. It proved most cost effective to remediate schools, and almost as cost-effective to remediate houses, but only if all house-holders could be encouraged to remediate their houses, once raised radon levels were found. To date only 10 % had done so. The research has made a major

  2. A new methodology for cost-effectiveness studies of domestic radon remediation programmes: Quality-adjusted life-years gained within Primary Care Trusts in Central England

    International Nuclear Information System (INIS)

    Coskeran, Thomas; Denman, Antony; Phillips, Paul; Gillmore, Gavin; Tornberg, Roger

    2006-01-01

    Radon is a naturally occurring radioactive gas, high levels of which are associated with geological formations such as those found in Northamptonshire and North Oxfordshire in the UK. The UK's National Radiological Protection Board have designated both districts as radon Affected Areas. Radiation levels due to radon, therefore, exceed 200 Bq m -3 , the UK's domestic Action Level, in over one percent of domestic properties. Because of radon's radioactivity, exposure to the gas can potentially cause lung cancer, and has been linked to some 2000 deaths a year in the UK. Consequently, when radiation levels exceed the Action Level, remediation against radon's effects is recommended to householders. This study examines the cost-effectiveness of remediation measures in Northamptonshire and North Oxfordshire by estimating cost per quality-adjusted life-year gained in four Primary Care Trusts, organisations that play a key public health policy role in the UK's National Health Service. The study is the first to apply this approach to estimating the cost-effectiveness of radon remediation programmes. Central estimates of cost per quality-adjusted life-year in the four Primary Care Trusts range from Pounds 6143 to Pounds 10 323. These values, when assessed against generally accepted criteria, suggest the remediation programmes in the trusts were cost-effective. Policy suggestions based on the estimates, and designed to improve cost-effectiveness further, are proposed for the four Primary Care Trusts and the UK's National Health Service

  3. Radon/radon-daughter measurement methods and instrumentation

    International Nuclear Information System (INIS)

    Rock, R.L.

    1977-01-01

    Radon-daughter measurement equipment and techniques have been continuously improved over the last 25 years. Improvements have been in the areas of accuracy, time and convenience. We now have miniaturized scalers and detectors available for measuring the alpha particle count rates from aerosol samples collected on filter papers. We also have small lightweight efficient pumps for conveniently collecting samples and we have various counting methods which allow us to choose between making very precise measurements or nominal measurements. Radon-daughter measurement methods used in uranium mines and mills are discussed including a personal radon-daughter-exposure integrating device which can be worn by miners

  4. Radon campaigns. Status report 2008

    International Nuclear Information System (INIS)

    Arvela, H.; Valmari, T.; Reisbacka, H.; Niemelae, H.; Oinas, T.; Maekelaeinen, I.; Laitinen-Sorvari, R.

    2008-12-01

    Radon campaigns aim at activating citizens to make indoor radon measurements and remediation as well as increasing the common awareness of indoor radon questions. Indoor radon increases the risk of lung cancer. Through radon campaigns Radiation and Nuclear Safety Authority (STUK) also promotes the attainment of those goals that the Ministry of Social Affairs and Health has set for municipal authorities in Finland for prevention of the harmful effects of radon. The Ministry of Social Affairs and Health supports this campaign. Radon campaigns were started in autumn 2003. By autumn 2008 the campaigns have been organised already in 64 regions altogether in 160 municipalities. In some municipalities they have already arranged two campaigns. Altogether 14 100 houses have been measured and in 2 100 of these the action limit of radon remediation 400 Bq / m 3 has been exceeded. When participating in radon campaigns the house owners receive a special offer on radon detectors with a reduced price. In 2008 a new practice was introduced where the campaign advertisements were distributed by mail to low-rise residential houses in a certain region. The advertisement includes an order / deposit slip with postage paid that the house owner can send directly to STUK to easily make an order for radon measurement. In the previous radon campaigns in 2003 - 2007 the municipal authorities collected the orders from house owners and distributed later the radon detectors. The radon concentrations measured in the campaign regions have exceeded the action limit of 400 Bq / m 3 in 0 - 39% of houses, depending on the region. The total of 15% of all measurements made exceeded this limit. The remediation activities have been followed by sending a special questionnaire on remedies performed to the house owners. In 2006 - 2007 a questionnaire was sent to those households where the radon concentration of 400 Bq / m 3 was exceeded during the two first campaign seasons. Among the households that replied

  5. Radon remedial techniques in buildings - analysis of French actual cases

    International Nuclear Information System (INIS)

    Dupuis, M.

    2004-01-01

    The IRSN has compiled a collection of solutions from data provided by the various decentralised government services in 31 French departments. Contributors were asked to provide a description of the building, as well as details of measured radon levels, the type of reduction technique adopted and the cost. Illustrative layouts, technical drawings and photographs were also requested, when available. Of the cases recorded, 85% are establishments open to the public (schools (70%), city halls (4%) and combined city halls and school houses (26%)), 11% are houses and 4% industrial buildings. IRSN obtained 27 real cases of remedial techniques used. The data were presented in the form of fact sheets. The primary aim of this exercise was to illustrate each of the radon reduction techniques that can be used in the different building types (with basement, ground bearing slab, crawl space). This investigation not only enabled us to show that combining passive and active techniques reduces the operating cost of the installation, but above all that it considerably improves the efficiency. The passive technique reduces the amount of radon in the building and thus reduces the necessary ventilation rate, which directly affects the cost of operating the installation. For the 27 cases recorded, we noted:(a) the application of 7 passive techniques: sealing of floors and semi-buried walls, together with improved aeration by installing ventilation openings or ventilation strips in the windows. Radon concentrations were reduced on average by a factor of 4.7. No measurement in excess of 400 Bq.m -3 (the limit recommended by the French public authorities) was obtained following completion of the works; (b) the application of 15 active techniques: depressurization of the underlying ground, crawl space or basement and/or pressurization of the building. Radon concentrations were reduced on average by a factor of 13.8. Radon concentrations of over 400 Bq.m -3 were measured in only 4 cases

  6. Radon programme in Czech Republic. Results, experience and future

    International Nuclear Information System (INIS)

    Hulka, J.; Thomas, J.; Fojtikova, I.; Vlcek, J.; Moucka, L.; Fronka, A.; Jilek, K.; Heribanova, A.; Slovak, J.; Barnet, I.; Burian, I.; Jiranek, M.; Cechak, T.

    2004-01-01

    The beginning of the radon programme in the Czech republic dates back to the early 1980s. Incorporated in national legislation (Atomic Act, Radiation Protection Decree), the programme includes now both preventive measures and interventions. Preventive measures are based on the control of major potential radon sources (soil gas, building material and supplied water) to prevent construction of new houses where the recommended indoor radon level of 200 Bq/m 3 would be exceeded. Radon risk (index) assessment of the individual building site bedrock in the case of new house siting and building protection as stipulated by the technical building code are obligatory. The estimation of the radon-related index of building sites is based on a standard method involving a set of radon soil and soil permeability measurements. In addition, producers of building materials are obligated to monitor natural radioactivity in their products. The activity index (including 40 K, 226 Ra and 232 Th) is used as a screening level for regulation of the potential indoor gamma dose rate, and the 226R a mass activity is used as a limiting value for radon exhalation. A similar regulatory system is in place for public water supplies based on obligatory radon, total alpha and total beta measurements. A survey of effectiveness of the preventive measures was carried out during the past years. It appeared, however, that the indoor radon level of 200 Bq/m 3 is exceeded in some 20 % of new houses. An unexpectedly low air exchange rate in modern energy-saving houses seems to be among the reasons. Remedial actions are aimed at promoting targeted indoor radon survey in existing buildings and helping owners to put reasonable remedial measures into effect. Governmental activities include representative and targeted indoor radon survey, subsidies for remediation measures and test measurements, and improving the level of public awareness of the radon issue. Indoor radon survey is targeted on radon-prone areas

  7. The Norwegian information campaign on radon

    International Nuclear Information System (INIS)

    Thommesen, G.; Strand, T.

    1999-01-01

    The responsibility for providing an overview of 'all factors in the environment which are or may be having a direct or indirect influence on the health - -' rests with the municipal health authorities. In order to enable the municipal staff throughout Norway to accomplish local radon surveys, an information campaign on radon, including printed information material and training courses, was carried out in 1998-99, primarily directed towards municipal civil servants. The two-day training courses comprised of lectures and a compendium covering basic knowledge on ionizing radiation, sources of radon, measurement techniques, health risk, prophylactic and remedial measures, design and accomplishment of survey projects, and information strategy. The printed information material includes booklets providing general information on radon (health risks, measurements, and mitigation), methods for measuring radon in indoor air and construction sites, action levels, and design of municipal radon surveys. Two posters have been issued, one mainly intended for public offices and waiting rooms to motivate the public for radon measurements, the other one intended for municipal personnel and governmental offices, the latter also issued as a collection of fact sheets intended for schools etc. the booklets are displayed on the Internet (www.nrpa.no). The site also contains links to further information on mitigation techniques and economic support to remedial measures. (au)

  8. Uncertainties of estimating average radon and radon decay product concentrations in occupied houses

    International Nuclear Information System (INIS)

    Ronca-Battista, M.; Magno, P.; Windham, S.

    1986-01-01

    Radon and radon decay product measurements made in up to 68 Butte, Montana homes over a period of 18 months were used to estimate the uncertainty in estimating long-term average radon and radon decay product concentrations from a short-term measurement. This analysis was performed in support of the development of radon and radon decay product measurement protocols by the Environmental Protection Agency (EPA). The results of six measurement methods were analyzed: continuous radon and working level monitors, radon progeny integrating sampling units, alpha-track detectors, and grab radon and radon decay product techniques. Uncertainties were found to decrease with increasing sampling time and to be smaller when measurements were conducted during the winter months. In general, radon measurements had a smaller uncertainty than radon decay product measurements. As a result of this analysis, the EPA measurements protocols specify that all measurements be made under closed-house (winter) conditions, and that sampling times of at least a 24 hour period be used when the measurement will be the basis for a decision about remedial action or long-term health risks. 13 references, 3 tables

  9. Reduction of radon concentration in a basement workplace: study of the problem and characterization of the main parameters affecting the radon concentration

    International Nuclear Information System (INIS)

    Chiaberto, E.M.; Magnoni, M.; Righino, F.; Costa Laia, R.

    2002-01-01

    In this work is described the method used for the mitigation of high radon concentrations found in a basement workplace, the ARPA laboratory used for the metrology of EMF. In this lab was in fact measured a radon concentration up to 1900 Bq/m 3 , a value largely exceeding the Italian limit for workplaces (500 Bq/m 3 ). The basement workplace affected by radon is a room of around 500 m 3 with no windows and only one door, during work usually close, and therefore with a very low ventilation rate. In this workplace, usually two persons spent about 6 hour per day. Therefore their exposure to the radon and its decay products can attain a considerable value. For this people, accordingly to the accepted dosimetric models, an effective dose of several mSv per year could be estimated (ICRP Publication n. 65, 1993). It is thus important to reduce the radon concentration to acceptable levels, i.e. at least lower than 500 Bq/m 3 . This paper deals not only with the simple method used for the remedial action, but also to the investigation of the relevant parameters affecting the radon concentration. In particular, the monitoring of the radon concentration before and after the remedial action, allowed the calculation of the radon entry rates (Bq/s) and the ventilation rates (s-1) in the different experimental condition

  10. Radon barrier: Method of testing airtightness

    DEFF Research Database (Denmark)

    Rasmussen, Torben Valdbjørn; Buch-Hansen, Thomas Cornelius

    2017-01-01

    The test method NBI 167/02 Radon membrane: Test of airtightness can be used for determining the airtightness of a radon barrier as a system solution. The test determines the air infiltration through the radon barrier for a number of levels of air pressure differences. The airflow through versus...... of the barrier with the low air pressure, through a well-defined opening, as a modification of the test method in general. Results, obtained using the improved test method, are shown for a number of radon barriers tested....

  11. Evaluation of experiences in long-term radon and radon-daughter measurements

    International Nuclear Information System (INIS)

    Young, J.A.; Jackson, P.O.; Thomas, V.W.

    1982-12-01

    Pacific Northwest Laboratory (PNL) is performing side-by-side measurements of radon and radon daughter concentrations using several instruments and techniques, and is comparing these measurements with side-by-side measurements made by other investigators at other locations. The standard deviation of the differences between the (natural) logarithms of the Terradex Track Etch radon concentrations and the logarithms of the Radon Progency Integrating Sampling Units (RPISU) radon daughter concentrations (S.D.-ln) measured in 50 buildings in Edgemont, South Dakota, was 0.37. Using this S.D.-ln, it can be calculated that if the Track Etch radon daughter concentration is 0.010 WL there should be only a 14% probability that the RPISU average would be greater than 0.015 WL, and only a 3% probability tht the RPISU average would be greater than 0.020 WL. If buildings had been cleared from remedial action when the Track Etch averages were less than 0.10 WL, then about 61% of the buildings would have been cleared from remedial action, and only a few percent of these buildings would have actually had average RPISU concentrations greater than 0.015 WL. The S.D.-ln between the Track Etch radon measurements and the RPISU radon daughter measurements made by ALARA at Grand Junction, the PERM radon measurements and the MOD-225 radon daughter measurements made by Mound Facility at Canonsburg and Middlesex, and the PERM and Track Etch radon measurements made by Mound Facility at Salt Lake City were similar to the S.D.-ln between the Track Etch radon measurements and the RPISU radon daughter measurements at Edgemont

  12. Control of radon in Finnish workplaces

    International Nuclear Information System (INIS)

    Markkanen, M.

    2002-01-01

    Natural radiation in Finland is regulated in the Finnish Radiation Act from 1992. Occupational exposure to natural radiation is regulated by an amendment of the Radiation Decree in 1998. The most important issues in Finland are radon in workplaces, radioactivity in drinking water and in building materials, and mining and industrial processes. Radon levels in mines have been measured regularly since 1972. Finland has an action level for radon in workplaces of 400 Bq/m 3 . Radon prone areas have been identified primarily from measurements of radon in dwellings. Radon measurements are compulsory in workplaces in radon prone areas unless it can be shown by other means that radon levels are low. A programme focusing on radon in workplaces was initiated in 1992. To date, radon measurements have been carried out in 10,000 workplaces and remedial actions have been taken in 200 of these. The average reduction in radon concentration in remediated buildings is about 1,500 Bq/m 3 . Identification of NORM industries is based on the radionuclide content of the materials used (>1.4 Bq/g U and >0.4 Bq/g Th). The occupational exposure should not exceed 1 mSv/y (excluding radon)

  13. Radon programme: presence and future

    International Nuclear Information System (INIS)

    Hulka, J.

    2009-01-01

    In this presentation an overview of radon programme experiences is presented. The paper summarises national radon policy, national programmes, legislation, the role of preventive measures and interventions with respect to existing and future exposure and knowledge of radon risk, problems of remediation strategies, practical protection in dwellings, radon measurements strategies, progress in radon measurement of an individual house (radon diagnosis), radon mapping process and sense of delineation of radon prone areas, natural radioactivity of building materials and radioactivity in public water and their role in the radon programme, public awareness on radon issue and publicity campaign. Some research activities are proposed aiming at effective solutions of radon issues in future

  14. Indoor Radon Concentration Related to Different Radon Areas and Indoor Radon Prediction

    Science.gov (United States)

    Juhásová Šenitková, Ingrid; Šál, Jiří

    2017-12-01

    Indoor radon has been observed in the buildings at areas with different radon risk potential. Preventive measures are based on control of main potential radon sources (soil gas, building material and supplied water) to avoid building of new houses above recommended indoor radon level 200 Bq/m3. Radon risk (index) estimation of individual building site bedrock in case of new house siting and building protection according technical building code are obligatory. Remedial actions in buildings built at high radon risk areas were carried out principally by unforced ventilation and anti-radon insulation. Significant differences were found in the level of radon concentration between rooms where radon reduction techniques were designed and those where it was not designed. The mathematical model based on radon exhalation from soil has been developed to describe the physical processes determining indoor radon concentration. The model is focused on combined radon diffusion through the slab and advection through the gap from sub-slab soil. In this model, radon emanated from building materials is considered not having a significant contribution to indoor radon concentration. Dimensional analysis and Gauss-Newton nonlinear least squares parametric regression were used to simplify the problem, identify essential input variables and find parameter values. The presented verification case study is introduced for real buildings with respect to various underground construction types. Presented paper gives picture of possible mathematical approach to indoor radon concentration prediction.

  15. Uranium mill tailings and radon

    International Nuclear Information System (INIS)

    Hanchey, L.A.

    1981-01-01

    The major health hazard from uranium mill tailings is presumed to be respiratory cancer resulting from the inhalation of radon daughter products. A review of studies on inhalation of radon and its daughters indicates that the hazard from the tailings is extremely small. If the assumptions used in the studies are correct, one or two people per year in the US may develop cancer as a result of radon exhaled from all the Uranium Mill Tailings Remedial Action Program sites. The remedial action should reduce the hazard from the tailings by a factor of about 100

  16. Uranium mill tailings and radon

    Energy Technology Data Exchange (ETDEWEB)

    Hanchey, L A

    1981-04-01

    The major health hazard from uranium mill tailings is presumed to be respiratory cancer resulting from the inhalation of radon daughter products. A review of studies on inhalation of radon and its daughters indicates that the hazard from the tailings is extremely small. If the assumptions used in the studies are correct, one or two people per year in the United States may develop cancer as a result of radon exhaled from all the Uranium Mill Tailings Remedial Action program sites. The remedial action should reduce the hazard from the tailings by a factor of about 100.

  17. Uranium mill tailings and radon

    Energy Technology Data Exchange (ETDEWEB)

    Hanchey, L A

    1981-01-01

    The major health hazard from uranium mill tailings is presumed to be respiratory cancer resulting from the inhalation of radon daughter products. A review of studies on inhalation of radon and its daughters indicates that the hazard from the tailings is extremely small. If the assumptions used in the studies are correct, one or two people per year in the US may develop cancer as a result of radon exhaled from all the Uranium Mill Tailings Remedial Action Program sites. The remedial action should reduce the hazard from the tailings by a factor of about 100.

  18. Measurement of exhalation rate of radon and radon concentration in air using open vial method

    International Nuclear Information System (INIS)

    Horiuchi, Kimiko; Ishii, Tadashi.

    1991-01-01

    It was recognized that more than half of total exposure dose on human subject is caused by radon and its decay products which originate from naturally occurring radioactive substances (1988 UNSCEAR). Since then the exhalation of radon from the ground surface has received increasing attention. The authors have developed a new method for the determination of radon in natural water using toluene extraction of radon and applying a liquid scintillation counter of an integral counting technique which is able to get the absolute counting of radon. During these studies, the authors found out that when a counting vial containing of Liquid scintillator (LS)-toluene solution, without a lid, is exposed to the atmosphere for a while, dissolution of radon clearly occurs due to high solubility of radon into toluene layer. To extend this finding for the determination of radon in the atmosphere, the authors devised a new method to actively collect the atmosphere containing radon in a glass bottle by discharging a definite amount of water in it, which is named as open-vial dynamic method. The radon concentration can be easily calculated after the necessary corrections such as the partition coefficient and others. Applying proposed method to measure the radon exhalation rate from the ground surface and radon concentration in air of the dwelling environment, radioactive mineral spring zone and various geological formation such as granitic or sedimentary rocks. (author)

  19. Protocol for the estimation of average indoor radon-daughter concentrations: Second edition

    International Nuclear Information System (INIS)

    Langner, G.H. Jr.; Pacer, J.C.

    1988-05-01

    The Technical Measurements Center has developed a protocol which specifies the procedures to be used for determining indoor radon-daughter concentrations in support of Department of Energy remedial action programs. This document is the central part of the protocol and is to be used in conjunction with the individual procedure manuals. The manuals contain the information and procedures required to implement the proven methods for estimating average indoor radon-daughter concentration. Proven in this case means that these methods have been determined to provide reasonable assurance that the average radon-daughter concentration within a structure is either above, at, or below the standards established for remedial action programs. This document contains descriptions of the generic aspects of methods used for estimating radon-daughter concentration and provides guidance with respect to method selection for a given situation. It is expected that the latter section of this document will be revised whenever another estimation method is proven to be capable of satisfying the criteria of reasonable assurance and cost minimization. 22 refs., 6 figs., 3 tabs

  20. Radon campaigns. Status report 2008; Radontalkoot. Tilannekatsaus 2008

    Energy Technology Data Exchange (ETDEWEB)

    Arvela, H.; Valmari, T.; Reisbacka, H.; Niemelae, H.; Oinas, T.; Maekelaeinen, I.; Laitinen-Sorvari, R.

    2008-12-15

    Radon campaigns aim at activating citizens to make indoor radon measurements and remediation as well as increasing the common awareness of indoor radon questions. Indoor radon increases the risk of lung cancer. Through radon campaigns Radiation and Nuclear Safety Authority (STUK) also promotes the attainment of those goals that the Ministry of Social Affairs and Health has set for municipal authorities in Finland for prevention of the harmful effects of radon. The Ministry of Social Affairs and Health supports this campaign. Radon campaigns were started in autumn 2003. By autumn 2008 the campaigns have been organised already in 64 regions altogether in 160 municipalities. In some municipalities they have already arranged two campaigns. Altogether 14 100 houses have been measured and in 2 100 of these the action limit of radon remediation 400 Bq / m3 has been exceeded. When participating in radon campaigns the house owners receive a special offer on radon detectors with a reduced price. In 2008 a new practice was introduced where the campaign advertisements were distributed by mail to low-rise residential houses in a certain region. The advertisement includes an order / deposit slip with postage paid that the house owner can send directly to STUK to easily make an order for radon measurement. In the previous radon campaigns in 2003 - 2007 the municipal authorities collected the orders from house owners and distributed later the radon detectors. The radon concentrations measured in the campaign regions have exceeded the action limit of 400 Bq / m3 in 0 - 39% of houses, depending on the region. The total of 15% of all measurements made exceeded this limit. The remediation activities have been followed by sending a special questionnaire on remedies performed to the house owners. In 2006 - 2007 a questionnaire was sent to those households where the radon concentration of 400 Bq / m3 was exceeded during the two first campaign seasons. Among the households that replied

  1. Human perception of radon risk and radon mitigation: Some remarks

    International Nuclear Information System (INIS)

    Neznal, M.; Neznal, M.

    2008-01-01

    The Radon program in the Czech Republic has a relatively long and rich history. Procedures, which enable to evaluate the risk of radon penetration from the ground, to protect new buildings, to find existing buildings with elevated indoor radon levels and to realise remedial measures in such buildings, have been developed, published and tested. In some cases, the whole system may fail due to psychological or sociological reasons. Three types of problems (conflicts) will be presented: human behaviour affecting measurement results, conflict between individual and 'all-society' points of view, interpretation of radon risk itself. (authors)

  2. Radon in Irish primary and post-primary schools. The results of a national survey

    International Nuclear Information System (INIS)

    Synnott, H.; Fennell, S.; Pollard, D.; Colgan, P.A.; Hanley, O.; O'Colmain, M.; Maloney, L.

    2004-05-01

    This report presents the results of a survey of radon concentrations in schools in the Republic of Ireland. The survey was carried out by the Radiological Protection Institute of Ireland (RPII) on behalf of the Department of Education and Science. A workplace Reference Level of 400 Bq/m3 is set down in national legislation. However, in the case of schools the RPII has recommended that, wherever possible, radon concentrations should be reduced to below 200 Bq/m3. The objective of the survey was to assess the distribution of radon in Irish schools and to identify those requiring remedial work to reduce radon exposure to children and staff. The survey was carried out on a phased basis from 1998 to 2002. All schools in the Free Education System were invited to participate. Indoor radon concentrations were measured using passive alpha track-etch detectors with a measurement period of one academic year from September to the following June. Measurements were completed in the ground floor classrooms and offices of 3444 schools, representing over 85% of the approximate 4000 primary and post-primary schools in Ireland. Of these, 898 had radon concentrations greater than 200 Bq/m3 and 307 had radon concentrations in excess of the national Reference Level for workplaces of 400 Bq/m3 in one or more ground floor rooms. The average radon concentration in the schools surveyed was 93 Bq/m3. Different remediation strategies have been adopted for schools with maximum radon concentrations between 200 and 400 Bq/m3 and for schools with radon concentrations in excess of 400 Bq/m3. In schools with radon concentrations below 400 Bq/m3, passive remediation through increased background ventilation is, where practicable, being used to reduce the radon concentrations. Where the initial radon concentration exceeded 400 Bq/m3, a remediation consultant assessed the school and remedial measures specific to each school have been designed. In the majority of these cases active remediation in the

  3. Radon diagnostics and tracer gas measurements

    International Nuclear Information System (INIS)

    Jilek, K.; Brabec, M.

    2004-01-01

    An outline is presented of the tracer gas technique, which is used for continuous measurements of air ventilation rate (generally time-varying) and for simultaneous estimation of air ventilation rate and radon entry rate, and some of its limitations are discussed. The performance of this technique in the calculation of the air ventilation rate is demonstrated on real data from routine measurements. The potential for air ventilation rate estimation based on radon measurements only is discussed. A practical application is described of the tracer gas technique to a simultaneous estimation of the air ventilation rate and radon entry rate in a real house where the effectiveness of radon remedy was tested. The following main advantages of the CO tracer gas techniques are stressed: (i) The averaging method continuous determination of the ventilation rate with good accuracy (≤ 20 %). (ii) The newly presented and verified method based on simultaneous measurements of radon concentration and CO gas concentration enables separate continuous measurements of the radon entry rate and ventilation rate. The results of comparative measurements performed with the aim to estimate the inaccuracy in determination of radon entry rate showed acceptable and good agreement up to approximately 10 %. The results of comparative measurements performed with the aim to estimate the mutual commensuration of the method to the determination of the ventilation rate confirmed the expected unreliability the two parametric non-linear regression method, which is the most frequently used method in radon diagnostic in the Czech Republic

  4. Radon and radon daughters in public, private and commercial buildings in communities associated with uranium mining and processing in Canada

    International Nuclear Information System (INIS)

    Eaton, R.S.

    1982-01-01

    The elevated indoor radon levels in certain communities in Canada have been studied. An overview of the investigational and remedial action programs are presented in this paper. It is suggested that radon daughter concentrations can be controlled by: (a) removing source; (b) placing a barrier between the source and the living space; (c) diverting the radon before it enters a building: (d) increasing the ventilation rate. All methods have been proven but no one technique is the most cost effective because of widely varying conditions found in older housing

  5. Methods of radon measurement and devices

    International Nuclear Information System (INIS)

    Miles, J.

    2004-01-01

    The following topics and instrumentation are discussed: The quantity to be measured; Active measurement methods (scintillation cells, ionisation chambers, electrostatic collection of decay products); Passive measurement methods (charcoal detectors; electret ion chambers; etched track detectors); and Detector considerations for large-scale surveys ('always on' or 'switchable' detectors?; response to radon-220; avoidance of electrostatic effects; quality assurance for passive radon detectors; quality control within the laboratory; external quality assurance; detectors need to be easily deliverable). It is concluded that the ideal detector for large scale surveys of radon in houses is a small, closed detector in a conducting holder which excludes radon-220, supported by rigorous quality assurance procedures. (P.A.)

  6. Assessment of current techniques for reduction of indoor radon concentration in existing and new houses in European countries

    International Nuclear Information System (INIS)

    Holmgren, O.; Arvela, H.

    2012-03-01

    Radon control technologies aim at the reduction of indoor radon concentrations in existing buildings and in new construction through remedial and preventive measures. In recent years, rising ecological awareness and rising energy costs have stimulated the development of low energy and passive houses to save energy. This report contains the analysis and assessment of current techniques and technologies used to achieve the reduction of indoor radon concentrations in existing and new houses with regard to the reduction efficiency and potential impact on energy consumption (qualitative analysis). A questionnaire was prepared and sent to all RADPAR partners in 14 different countries in order to gather national information about the current remediation and prevention techniques. Responses with variable amounts of information were obtained. Based on the questionnaire responses, the status of radon remediation and prevention in each country was assessed, in addition to the reduction efficiency and potential impact on energy consumption of the current remediation and prevention techniques. The number of dwellings with an elevated indoor radon concentration typically ranges from tens of thousands to a million. The percentage of these houses already remediated varies from zero to 15%. Preventive measures in new construction have been taken from a small number of houses to over half a million houses. The research data on the current situation, the number of houses with preventive measures and the efficiency of these measures is currently still quite inadequate. Assessment of the techniques and also the surveys aiming at exploring the impact of remedial and preventive measures is greatly needed in order to promote the work at the national level. The most efficient remediation method is the active sub-slab depressurization (SSD) and the radon well, for which the reduction in the radon concentration is typically 70 - 95%. Other methods, such as sealing entry routes and improving

  7. Radon Remediation and Protective Measures in UK Buildings: The Work of the Building Research Establishment Ltd. (invited paper)

    International Nuclear Information System (INIS)

    Scivyer, C.; Woolliscroft, M.

    1998-01-01

    The scope is described of work carried out by the Building Research Establishment Ltd (BRE) in the UK. BRE, funded by the UK Department of the Environment and the Regions (DETR), have been carrying out research into radon in UK buildings for over 10 years. Research has resulted in the successful development of a range of reliable, practical and cost effective radon remedial measures. The measures, which are described in a series of practical guides, are applicable to almost all building types found in the UK, and would be appropriate for use in many buildings found in other countries. The principal aims of this work have been to develop practical, cost effective and appropriate methods for reducing radon levels in existing buildings and to develop protective measures for new buildings. It is considered particularly important to ensure that measures recommended not only reduce radon levels, but that they do not cause adverse effects to the structure or indoor environment, whilst also being cost effective. A comprehensive series of field trials has been undertaken to test a variety of different solutions in more than 300 existing buildings and protective measures in more than 500 new buildings. To support the field trials BRE have a test house located in the South West of England which allows researchers access to a real house without causing considerable disruption to householders in conducting experiments. BRE have also carried out computer modelling work to try to understand the processes which cause radon entry, and how measures taken might affect these processes. A comprehensive database of work carried out in some 300 UK houses is also maintained. (author)

  8. Training and Accreditation for Radon Professionals in Sweden

    International Nuclear Information System (INIS)

    Soderman, A. L.

    2003-01-01

    Radon training courses and seminars of different kinds have been arranged in Sweden since the early 1980s. A commercial educational company initiated the first regular training courses in 1987. Up to 1990 about 400 persons had attended courses in radon measurement and radon mitigation methods. In 1991 the first in a series of courses focussed on radon from the ground and production of radon risk maps organised. From 1991 it has been possible to obtain accreditation for measurements of indoor radon in Sweden and from 1997 also for measurements of radon in water. Even if accreditation s is voluntary, in Sweden accredited laboratories perform most measurements, both for indoor air and water. A condition for accreditation in to have passed the examination following the training courses at SSI, SO far, three major companies have obtained accreditation for measurement of indoor radon and four have been accredited for measurements of radon in water. Education on radon is also given at universities and institutes of technology. A two-day course is included in the education for environmental health officers. A number of training courses aimed at real state agents have been organised by SSI through the years. During the autumn of 2001 altogether 400 authorised real estate agents attended a series of regional half-day courses. In 1995 SSI arranged an international training course, Radon Indoor Risk and Remedial Actions, in Stockholm for the European commission. About 40 scientists from all over Europe attended the course, which much appreciated by the participants. Today SSI's Radon Training Programme comprises five different courses, a Basic radon Course and four continuation courses: Radon measurements, Radon remedial measures, Radon in water and Radon investigation and risk map production. The courses are arranged twice a year, in spring and autumn, except the Radon risk map production course, which is arranged about every second year. Altogether, between 1991 and 2003

  9. Geological Structure and Radon Hazards in Lublin Region

    Directory of Open Access Journals (Sweden)

    Lucjan Gazda

    2018-03-01

    Full Text Available The purpose of the study was to show the relationship between the geological structure of the Lublin region (eastern Poland and radon concentrations in the ground air, and therefore, in the indoor environment of buildings located in that area. The study was based on the information pertaining to the geological structure of Lublin region available in the literature. The radon concentrations in buildings, caves, wells, as well as coal, phosphate and chalk mines were measured with both passive and active methods. Elemental analyses and uranium and lead isotope analyses of ground rocks were also performed. The conducted studies indicated that the sources of radon in Lublin region constitute Paleogene and Mesozoic sedimentary rocks rich in radionuclides. Application of radon remediation methods is recommended in the existing buildings located in the vicinity of these rocks, which are characterized by relatively high radon exhalations. On the other hand, the designed buildings should employ the measures protecting against harmful effects of radon presence.

  10. The Pennsylvania radon story

    International Nuclear Information System (INIS)

    Gerusky, T.M.

    1987-01-01

    In December 1984, the Pennsylvania Bureau of Radiation Protection found itself confronted with the discovery of a home in eastern Pennsylvania having the highest level of radon daughters ever reported. The Bureau responded with a massive radon monitoring, educational, and remediation effort. As of November, 1986, over 18,000 homes had been screen for radon daughters, of which approximately 59% were found to have levels in excess of the 0.020 Working Level guideline. Pennsylvania's response to the indoor radon problem is detailed in this article

  11. Workshop on dosimetry for radon and radon daughters

    International Nuclear Information System (INIS)

    Turner, J.E.; Holoway, C.F.; Loebl, A.S.

    1978-05-01

    Emphasis is placed on the dosimetry for radon and daughters, rather than on monitoring and instrumentation. The objectives of the meeting were to exchange scientific information, to identify problem areas in radon-daughter dosimetry, and to make any observations or recommendations by the participants through issuance of this report. The discussion topics included the history of dosimetry for radon and daughters, human data, aerosols, deposition and movement in the respiratory tract, dose calculations, dose-to-working-level-month (WLM) conversion factors, animal experiments, and the development of regulations and remedial criteria for reducing population exposures to radon daughters. This report contains a summary of Workshop discussions plus individual statements contributed by several of the participants. The outstanding problem areas from the standpoint of dosimetry appear to involve the appropriate lung organ mass to be used (average lung-tissue dose vs. high-level local dose); recognition of the discrete, rather than continuous, structure of the mucus; lack of knowledge about lung clearance; the variability of dose with the degree of disequilibrium and the unattached fraction of radon daughters for a given WLM; and questions about the character of uranium mine atmospheres actually breathed in the older mines from which much of the epidemiological information originates. The development of criteria for taking remedial action to reduce exposures involves additional concerns of basing long-term risk assessment on short-term sampling and applying WLM data for miners to general populations

  12. Radon programme in the Czech Republic

    International Nuclear Information System (INIS)

    Hulka, J.; Thomas, J.

    2003-01-01

    The framework of the Radon programme in the Czech republic includes both precautionary measures and interventions. The programme informally started in early eighties has been now incorporated in national legislation (Atomic Act, Radiation Protection Decree, etc.). Aim of precautionary measures is to avert construction of building above natural radiation guidance levels (200 Bq/m 3 for indoor radon concentration and 0.5 Sv/h for gamma dose rate) by protection of new buildings against soil radon ingress, by regulation of natural radioactivity in building materials and supplied water. Aim of interventions is to identify buildings affected by enhanced natural radioactivity and help owners to put into effect reasonable remedial measures. Two sets of intervention levels for indoor natural exposure were established: guidance intervention levels 400 Bq/m 3 (indoor radon), 1.0 Sv/h (indoor gamma dose rate) and limit values 4000 Bq/m 3 and 10 Sv/h. The radon programme is based both on governmental and private activities. The governmental activities include representative and targeted indoor radon survey, subsidy for radon mitigation, mitigation test measurements and public information on radon issue. The private activities include radon measurement (radon index of building site, indoor measurements, radon diagnosis) and remedial measures. More than 100 commercial companies were authorised by Radiation Protection Authority (SUJB) to provide these measurements

  13. Smoking cessation programmes in radon affected areas: can they make a significant contribution to reducing radon-induced lung cancers?

    International Nuclear Information System (INIS)

    Denman, A.R.; Groves-Kirkby, C.J.; Timson, K.; Shield, G.; Rogers, S.; Phillips, P.S.

    2008-01-01

    Domestic radon levels in parts of the UK are sufficiently high to increase the risk of lung cancer in the occupants. Public health campaigns in Northamptonshire, a designated radon affected area with 6.3% of homes having average radon levels over the UK action level of 200 Bq m -3 , have encouraged householders to test for radon and then to carry out remediation in their homes, but have been only partially successful. Only 40% of Northamptonshire houses have been tested, and only 15% of householders finding raised levels proceed to remediate. Of those who did remediate, only 9% smoked, compared to a countywide average of 28.8%. This is unfortunate, since radon and smoking combine to place the individual at higher risk by a factor of around 4, and suggests that current strategies to reduce domestic radon exposure are not reaching those most at risk. During 2004-5, the NHS Stop Smoking Services in Northamptonshire assisted 2,808 smokers to quit to the 4-week stage, with some 30% of 4-week quitters remaining quitters at 1 year. We consider whether smoking cessation campaigns make significant contributions to radon risk reduction on their own, by assessing individual occupants' risk of developing lung cancer from knowledge of their age, gender, and smoking habits, together with he radon level in their house. The results demonstrate that smoking cessation programmes have significant added value in radon affected areas, and contribute a greater health benefit than reducing radon levels in the smokers' homes, whilst they remain smokers. Additionally, results are presented from a questionnaire-based survey of quitters, addressing their reasons for seeking help in quitting smoking, and whether knowledge of radon risks influenced this decision. The impact of these findings on future public health campaigns to reduce the impact of radon and smoking are discussed. (author)

  14. Inverse method for determining radon diffusion coefficient and free radon production rate of fragmented uranium ore

    International Nuclear Information System (INIS)

    Ye, Yong-jun; Wang, Li-heng; Ding, De-xin; Zhao, Ya-li; Fan, Nan-bin

    2014-01-01

    The radon diffusion coefficient and the free radon production rate are important parameters for describing radon migration in the fragmented uranium ore. In order to determine the two parameters, the pure diffusion migration equation for radon was firstly established and its analytic solution with the two parameters to be determined was derived. Then, a self manufactured experimental column was used to simulate the pure diffusion of the radon, the improved scintillation cell method was used to measure the pore radon concentrations at different depths of the column loaded with the fragmented uranium ore, and the nonlinear least square algorithm was used to inversely determine the radon diffusion coefficient and the free radon production rate. Finally, the solution with the two inversely determined parameters was used to predict the pore radon concentrations at some depths of the column, and the predicted results were compared with the measured results. The results show that the predicted results are in good agreement with the measured results and the numerical inverse method is applicable to the determination of the radon diffusion coefficient and the free radon production rate for the fragmented uranium ore. - Highlights: • Inverse method for determining two transport parameters of radon is proposed. • A self-made experimental apparatus is used to simulate radon diffusion process. • Sampling volume and position for measuring radon concentration are optimized. • The inverse results of an experimental sample are verified

  15. Radon and its measurement

    International Nuclear Information System (INIS)

    Penzo, Silvia

    2006-03-01

    The work reviews the topics concerning the problem of the indoor radon and its measurement. The initial stage deals with the general features of radon, from the historical remarks about its discovery to the formation mechanisms in the soil, then passing to describe the transport processes that lead the radon to enter into the buildings. The mean radon concentration distribution among the Italian regions is reported and compared with the situation in the other countries of the world. A particular importance is given to present the national law concerning the radioprotection from the natural sources of ionizing radiations; a paragraph is completely devoted to this argument and to discuss the differences between the Italian approach and the regulations applied in the Test of Europe for both workplaces and dwellings. Chapter 3 describes the different detectors and methods to measure the radon and its short mean live decay products concentrations, together with the operative procedures and guides provided by the Italian law and by the international bodies. As an example of typical radon passive measurement device. the new ENEA detector developed at the Institute of Radioprotection is presented and discussed. Appendix 1 is entirely devoted to discuss the main remedial actions for decreasing the radon indoor concentration both for old and new buildings; appendix 2 reports the main quantities related to radon and radioprotection [it

  16. Radon reduction in homes constructed on saprolite in the Central Appalachians

    International Nuclear Information System (INIS)

    Mose, D.G.; Mushsrush, G.W.; Slone, J.E.

    1997-01-01

    A 3-year study of indoor radon in more than 1000 homes in northern Virginia and southern Maryland was conducted using 3-month exposure alpha-track monitors. In a study set of 200 homes, first-floor indoor radon concentrations, which most closely approximates home exposure levels, averaged slightly more than 3 pCi/l. In a study set of 100 homes, sub-slab ventilation was used to reduce indoor radon concentrations. Interest in remediation was related to public perception of the hazardous nature of radon; people living in homes with indoor radon measurements of more than 4 pCi/l were more likely to participate in the remediation phase of the project. Sub-slab ventilation was successful in more than 90% of the homes in reducing indoor radon from concentrations as high as 30 pCi/ to less than 4 pCi/l, at least for the entire year of post-remediation radon measurements. (orig.)

  17. Modified technology in new constructions, and cost effective remedial action in existing structures, to prevent infiltration of soil gas carrying radon

    International Nuclear Information System (INIS)

    Ericson, S.O.; Schmid, H.; Clavensjo, B.

    1984-01-01

    The general principles and mechanisms of how soil gas carrying radon infiltrates from the foundation bed and subsoil into buildings are discussed. The Swedish Building Research Council has funded experiments and evaluations of cost effective remedial actions. The work has concerned existing dwellings with high concentration of radon where this is a result of infiltrating soil gas and/or exhalation from building materials. A review is given of experience and results acquired up to the summer of 1983. 100 dwellings have been erected with consideration of possible infiltration of soil gas. Modification of design, added costs (investment and operation) and resulting concentration of radon in indoor air is discussed. In general minor modifications are sufficient. (author)

  18. Absolute measurement method of environment radon content

    International Nuclear Information System (INIS)

    Ji Changsong

    1989-11-01

    A portable environment radon content device with a 40 liter decay chamber based on the method of Thomas double filter radon content absolute measurement has been developed. The correctness of the method of Thomas double filter absolute measurement has been verified by the experiments to measure the sampling gas density of radon that the theoretical density has been known. In addition, the intrinsic uncertainty of this method is also determined in the experiments. The confidence of this device is about 95%, the sensitivity is better than 0.37 Bqm -3 and the intrinsic uncertainty is less than 10%. The results show that the selected measuring and structure parameters are reasonable and the experimental methods are acceptable. In this method, the influence on the measured values from the radioactive equilibrium of radon and its daughters, the ratio of combination daughters to the total daughters and the fraction of charged particles has been excluded in the theory and experimental methods. The formula of Thomas double filter absolute measuring radon is applicable to the cylinder decay chamber, and the applicability is also verified when the diameter of exit filter is much smaller than the diameter of inlet filter

  19. Radon concentrations in contaminated and uncontaminated premises in two Ontario towns

    International Nuclear Information System (INIS)

    Aitken, J.H.; Baker, E.G.; Chatterjee, R.M.; Kusiak, R.; Tai-Pow, J.

    1977-01-01

    Radon-222 concentrations in air were measured by grab sampling in a large number of private homes and other buildings in the town of Port Hope, Ontario. The purpose of the measurements is to identify places where a health hazard might exist due to improper disposal of radium-contaminated materials. Contaminated fill, rubble, lumber, and other building materials have been found in a number of premises in the town. Radon concentrations up to 750 pCi/l have been found in some homes. The thrust of the program is to identify quickly places where concentrations might be high enough to justify some prompt interim remedial action such as installation of special ventilation systems, pending final remedial work by removal of the contamination. The methods and instrumentation immediately available are those formerly used for radon-in-breath analysis in radium workers. Grab sampling for radon and gamma surveying in every building in town are used together in a screening program. Experience showed that both radon sampling and gamma surveying are required to identify contaminated locations

  20. The risks from radon in homes

    International Nuclear Information System (INIS)

    Duggan, M.J.

    1990-01-01

    A report has been proposed by a Working group of the Institute of Radiation Protection on the risks from radon in homes. The report includes a historical perspective, properties and behavior of radon and its daughters, measurement of radon exposure in UK homes, remedial action, quantification of the risk and lifetime risks from other causes. (UK)

  1. Wind direction correlated measurements of radon and radon progeny in atmosphere: a method for radon source identification

    International Nuclear Information System (INIS)

    Akber, R.A.; Pfitzner, J.; Johnston, A.

    1994-01-01

    This paper describes the basic principles and methodology of a wind direction correlated measurement technique which is used to distinguish the mine-related and background components of radon and radon progeny concentrations in the vicinity of the ERA Ranger Uranium Mine. Simultaneous measurements of atmospheric radon and radon progeny concentrations and wind speed and direction were conducted using automatic sampling stations. The data were recorded as a time series of half hourly averages and grouped into sixteen 22.5 degrees wind sectors. The sampling interval and the wind sector width were chosen considering wind direction variability (σ θ ) over the sampling time interval. The data were then analysed for radon and radon progeny concentrations in each wind sector. Information about the wind frequency wind speed seasonal and diurnal variations in wind direction and radon concentrations was required for proper data analysis and interpretation of results. A comparison with model-based estimates for an identical time period shows agreement within about a factor of two between the two methods. 15 refs., 1 tab., 5 figs

  2. Radon in Syrian houses

    International Nuclear Information System (INIS)

    Othman, I.; Hushari, M.; Raja, G.; Alsawaf, A.

    1996-01-01

    A nationwide investigation of radon levels in Syrian houses was carried out during the period 1991-1993. Passive radon diffusion dosemeters using polycarbonate detectors were distributed in houses all over Syria. Detectors were subjected to electrochemical etching to reveal latent tracks of alpha particles. The mean radon concentration in Syrian houses was found to be 45 Bq m -3 with some values several times higher. This investigation indicated that there were a few houses in Syria that require remedial action. Most houses that have high levels of radon were found in the southern area, especially in the Damascus governorate. The study also indicated that radon concentrations were higher in old houses built from mud with no tiling. (author)

  3. Radiation and Radon Survey of Akchatau (Khazakstan) and Experience with Radon Remedial Measures

    International Nuclear Information System (INIS)

    Soroka, Y.; Molchanov, A.

    1998-01-01

    A radiation survey of the territory of Akchatau settlement has been carried out. The main factors affecting the high content of radon in dwelling houses were revealed. The experiment on isolation of under floor spaces was carried out to prevent the entry of radon-containing soil gas into living rooms. The repair works efficiency for decreasing of the radon content in hazardous houses was analysed. The survey showed a need for regulation of the value of 222 Rn exhalation on the territories planned for construction works. (author)

  4. Outdoor radon monitoring plan for the UMTRA Project sites

    International Nuclear Information System (INIS)

    1986-02-01

    This document describes the monitoring schedules and methods used to measure ambient radon concentrations around Uranium Mill Tailings Remedial Action (UMTRA) Project sites. Radon monitoring at both processing sites and disposal sites is performed primarily for two reasons. The first, and foremost, of these is to provide a means to keep the off-site radon concentrations during the construction activities As Low As Reasonably Achievable (ALARA). The second purpose is to provide a basis for comparison with the EPA standards developed for the UMTRA Project. Radon monitoring data are also used to demonstrate compliance with ambient concentration standards and for public information due to concern about potential radiation releases during construction. 1 fig., 1 tab

  5. Recommended action levels for radon in dwellings

    International Nuclear Information System (INIS)

    1988-01-01

    The recommendation made by a group appointed by the Directorate of Public Health, arrives at the conclusion that radon in Norwegian dwellings implies a substantial health problem for the country. For this reason it is recommended that actions should be taken to reduce the radiation exposure from radon in Norway. Upper levels for such actions are set to 200 Bq/m 3 (radon in air of dwellings) for new contructions. For existing dwellings having concentrations of 200 - 800 Bq/m 3 , simple and unexpensive remedial actions to reduce levels are sufficient. When levels exceed 800 Bq/m 3 , more elaborate and costly actions are necessary. An evaluation of the extent of the radon problem in Norway is included, together with a survey of the cost and benefit involved in choosing various levels for remedial actions

  6. A survey on radon reduction efficiency of zeolite and bentonite in a chamber with artificially elevated radon concentration

    International Nuclear Information System (INIS)

    Mortazavi, S.M.J.

    2007-01-01

    Complete text of publication follows. Objective: Zeolite which is made of a special crystalline structure is a naturally occurring mineral group and can be used in radioactive waste management for site remediation /decontamination. There are a wide variety of naturally occurring and synthetic zeolites, each with a unique structure. The cations in zeolite are highly mobile and can be exchanged for other cationic species. On the other hand, bentonite forms from weathering of volcanic ash. This material may be used as an engineering barrier to enclose nuclear waste. In this study, radon reducing properties of zeolite and bentonite have been investigated. Methods: Using radioactive lantern mantle, a radon prone area with radon levels reaching the EPA's action level (200 Bq/m 3 ) was designed. Two sets of identical chambers (cylindrical chambers, diameter 10 cm, height 16 cm) were used in this study. No zeolite/bentonite was used in the 1 st set of the chambers. A thin layer of either zeolite or bentonite powder was applied to the base of the first set of chambers. An unburned radioactive lantern mantle (activity 800 Bq) was placed in all chambers (both sets) to artificially increase the radon level inside the chamber and simulate the condition of a radon prone area. Radon level monitoring was performed by using a PRASSI portable radon gas survey meter. Results: After placing the cap on its place, the radon levels inside the 1 st set of the chambers were 871.9, 770.3, 769.2 and 635.7 Bq/m 3 after 15, 30, 45 and 60 minutes respectively. Zeolite significantly decreased the radon concentration inside the chambers and radon levels were 367.9, 435.4, 399.0 and 435.4 Bq/m 3 after 15, 30, 45 and 60 minutes. The observed reduction in the radon level was statistically significant. As the radon concentrations in identical chambers with Bentonite were 550.7, 526.5, 536.2 and 479.8 Bq/m 3 after 15, 30, 45 and 60 minutes respectively, it is evident that zeolite is more efficient in

  7. Contribution of radon and radon daughters to respiratory cancer

    International Nuclear Information System (INIS)

    Harley, N.; Samet, J.M.; Cross, F.T.; Hess, T.; Muller, J.; Thomas, D.

    1986-01-01

    This article reviews studies on the contribution of radon and radon daughters to respiratory cancer and proposes recommendations for further research, particularly a national radon survey. The steady-state outdoor radon concentration averages 200 pCi/m3, and indoor levels are about 4 times higher. The primary source of radon in homes is the underlying soil; entry depends on multiple variables and reduced ventilation for energy conservation increases indoor radon levels. Occupational exposures are expressed in units of radon daughter potential energy concentration or working level (WL). Cumulative exposure is the product of the working level and the time exposed. The unit for cumulative exposure is the working level month (WLM). The occupational standard for radon exposure is 4 WLM/year, and 2 WLM/year has been suggested as a guideline for remedial action in homes. Epidemiologic studies show that miners with cumulative radon daughter exposures somewhat below 100 WLM have excess lung cancer mortality. Some 3% to 8% of miners studied have developed lung cancer attributable to radon daughters. All of the underground mining studies show an increased risk of lung cancer with radon daughter exposure. All cell types of lung cancer increased with radon exposure. If radon and smoking act in a multiplicative manner, then the risk for smokers could be 10 times that for nonsmokers. The potential risk of lung cancer appears to be between 1 and 2 per 10,000/WLM, which yields a significant number of lung cancers as some 220 million persons in the United States are exposed on average to 10 to 20 WLM/lifetime

  8. GAC as a method for radon abatement

    International Nuclear Information System (INIS)

    Martin, R.D.; Smith, K.A.

    1990-01-01

    Perhaps one of the most mysterious abatement procedures is that of the remediation of waterborne radon contamination in residential structures. Many mitigators have been led to believe that the use of GAC as an abatement technique is in appropriate due to the potential creation of a hazardous waste disposal problem. This paper sheds light on the use of GAC as a true alternative to costly aeration mitigation techniques, and can be used as a resource tool for mitigators who need to understand the limits of activity surrounding GAC, and what, if any, shielding may be needed for the protection of residential occupants

  9. Comparison of radon and radon-daughter grab samples obtained during the winter and summer

    International Nuclear Information System (INIS)

    Karp, K.E.

    1987-08-01

    The Technical Measurements Center (TMC), under the auspices of the US Department of Energy (DOE) Uranium Mill Tailings Remedial Action (UMTRA) program, is investigating short-term methods for estimating annual average indoor radon-daughter concentrations (RDC). A field study at 40 sample locations in 26 residential structures in Grand Junction, Colorado, was conducted once in the winter and once in the summer. The short-term methods investigated as part of this study include ten-minute radon and radon-daughter grab sampling and hourly RDC measurements. The results of the field study indicate that ten-minute radon grab samples from basement locations are reproducible over different seasons during controlled sampling conditions. Nonbasement radon and RDC grab samples are highly variable even when the use of the location by the occupant is controlled and the ventilation rate is restricted. The grab sampling was performed under controlled occupied conditions. These results confirm that a short-term radon or RDC measurement in a nonbasement location in a house is not a standardized measurement that can be used to infer an annual average concentration. The hourly RDC measurements were performed under three sets of conditions over a 72-hour period. The three sets of conditions were uncontrolled occupied, controlled occupied, and controlled unoccupied. These results indicate that it is not necessary to relocate the occupants during the time of grab sampling. 8 refs., 8 figs., 10 tabs

  10. Radon risk communication research: Practical lessons

    International Nuclear Information System (INIS)

    Fisher, A.; Johnson, F.R.

    1990-01-01

    Those responsible for state and local radon programs often express frustration about the small share of homes that have been tested for radon, and the small share of those with high readings that have been mitigated. There are now a number of completed studies that have examined how well alternative ways of communicating about radon risk have accomplished the goals of motivating appropriate testing and mitigation. This paper summarizes the research results that are most crucial for planning and implementing effective radon risk communication programs. We identify six reasons why people do not respond to radon as a serious threat and provide some remedies suggested by radon studies

  11. The impact of occupancy patterns on the assessment of the value of domestic radon remediation programmes in the UK

    International Nuclear Information System (INIS)

    Denman, A.R.; Gulliver, J.; Kennedy, C.A.; Briggs, D.; Phillips, P.S.

    2000-01-01

    Northamptonshire is one of the areas in the UK affected by radon with 6.3% of houses are above the Action Level of 200 Bq m -3 . The costs and benefits of remediation of domestic properties in Northamptonshire has been studied (1), and found to be similar to theoretical predictions, and justifiable compared to other radiation dose reduction programmes. One key assumption is the time spent by each occupant within the home. Denman and Phillips (1) assumed 50% occupancy to eliminate any exposure at the workplace, or whilst out of the home. However, the NRPB, using 1984 data, had previously assessed that be average occupancy in the UK was around 80%. This paper presents new occupancy data for Northampton, and assesses its impact on the assessment of remediation programmes. The occupancy of a sample of the population in suburban Northamptonshire was assessed using a telephone questionnaire in the early evening, when previous studies had shown it to be at its greatest. The respondent was asked about their activity over the last 24 hours, noting the time spent indoors, travelling, and in any other building. Only one person in each household was questioned. Data from 286 respondents was obtained in total. Occupancy in the home had a bimodal distribution, with a peak at around 50% (12 hour) occupancy, and another peak close to total occupancy. The average occupancy for the whole sample was 17.28 hours (72%). Data will also be presented for sub-groups of the population, including similar surveys of school children and students, where the average occupancy is much less. These groups have different occupancy patterns. The retired, invalids, and young mothers spend most time in the home, and children, students, and working people spent most time our of the home. 65 remediated homes have now been studied in Northamptonshire, and at 5% occupancy the collective dose reduction was estimated to be 2.22 man-sieverts. Using NRPB data of 80% occupancy, this would be 3.55 man

  12. Procedure manual for the estimation of average indoor radon-daughter concentrations using the filtered alpha-track method

    International Nuclear Information System (INIS)

    George, J.L.

    1988-04-01

    One of the measurement needs of US Department of Energy (DOE) remedial action programs is the estimation of the annual-average indoor radon-daughter concentration (RDC) in structures. The filtered alpha-track method, using a 1-year exposure period, can be used to accomplish RDC estimations for the DOE remedial action programs. This manual describes the procedure used to obtain filtered alpha-track measurements to derive average RDC estimates from the measurrements. Appropriate quality-assurance and quality-control programs are also presented. The ''prompt'' alpha-track method of exposing monitors for 2 to 6 months during specific periods of the year is also briefly discussed in this manual. However, the prompt alpha-track method has been validated only for use in the Mesa County, Colorado, area. 3 refs., 3 figs

  13. Discussion on the source of radon in uranium exploration method using radon-released thermal effect in minerals

    International Nuclear Information System (INIS)

    Su Shoutian.

    1985-01-01

    This paper considers the problem of the source of radon in uranium exploration method using radon-released thermal effect. In minerals by means of scintillation emanometry, we have carried out the measurement on radon content in minerals at various temperature in barren and ore-bearing granites of the granite-type uranium deposit No. 752, and inclusion decrepitation method has also been used to determine the temperature of decrepitation and its relative frequency. It was found from experiments that heated samples may release most of radon prior to inclusion decrepitation, radon released from thermal effect was, on the contrary, very little at temperature intervals of inclusion decrepitation on a large scale basis. When inclusions were ground after radon releasing, it would still release from inclusions after reheating. The radon content calculated from uranium content in inclusions is lower than the sensitivity of the determination method, so it is too difficult to be determined, indicating that the radon content released is not related to inclusions. Samples were determined by uranium chemical analysis and radium radiochemical analysis and it is obvious to note that the radon content released from thermal effect in minerals is positively correlated to the uranium and radium content. Various kinds of experiments suggest that radon is not derived from inclusions but from the whole mineral

  14. Modified technology in new constructions, and cost effective remedial action in existing structures, to prevent infiltration of soil gas carrying radon

    International Nuclear Information System (INIS)

    Ericson, S.O.; Schmied, H.; Clavensjoe, B.

    1984-01-01

    The general principles and mechanism of how soil gas infiltrates and carries radon from the foundation bed and subsoil into buildings are discussed. The Swedish Building Research Council has funded experiments and evaluation of cost effective remedial actions. The work has concerned existing dwellings with high concentration of radon, resulting from infiltrating soil gas and/or exhalation from building materials. A review and evaluation is given of experience and results acquired up to the summer of 1984. 100 dwellings have been constructed with consideration of possible infiltration of soil gas. In general minor modifications are sufficient to prevent infiltration. (Author)

  15. The cost-effectiveness of remedial and preventative measures against radon in Norwegian dwellings

    International Nuclear Information System (INIS)

    Strand, T.; Aanestad, K.

    2006-01-01

    Full text of publication follows: The indoor radon concentrations in Norway are among the highest in Europe. This is partly explained by the geology due to the large occurrences of radium rich soil and bedrock (e.g. alum shale and uranium rich granites), large occurrences of highly permeable unconsolidated sediments (e.g. moraines and eskers), and the construction of buildings due to the cold climate. An additional factor is the extensive use of highly permeable light expanded clay aggregates in the foundation construction. Entry of radon from the building ground is the dominant source of indoor radon in Norway. Based on the results of nation-wide surveys it has been concluded that most homes with high levels of radon are located on highly permeable sediments, and some of the homes on are sometimes very difficult and expensive to mitigate. In order to limit the mitigation costs it is therefore important the cost -effectiveness of measures is optimised. In this paper, the results of a Norwegian analysis of the cost -effectiveness of remedial measures in existing dwellings and preventative measures in new buildings will be presented. The analysis on measures in existing dwellings is based on data from approximately 1100 buildings which were mitigated by grants from the Government during the National Action Plan against Cancer between 1999 and 2003. The results show that the mitigation costs are significantly higher than earlier estimates based on controlled experiments in research projects, and it seem as though the mitigation costs have been significantly underestimated in earlier cost-effect analysis. There are several factor that have contributed to an increase of the mitigation costs and some of these factors will be discusses in more detail in this paper. The upper level for new dwellings is 200 Bq/m 3 and it is generally recommended by the Norwegian authorities that preventative measures are implemented in all new dwellings. By this strategy the costs of

  16. Evaluation method of radon preventing effect in underground construction

    International Nuclear Information System (INIS)

    Luo Shaodong; Deng Yuequan; Dong Faqin; Qu Ruixue; Xie Zhonglei

    2014-01-01

    Background: It's difficult to evaluate the radon prevention effect because of the short operating time of measuring instrument under the circumstances of high humidity in underground construction. Purpose: A new rapid method to evaluate the radon prevention efficiency of underground construction was introduced. Methods: The radon concentrations before and after shielding operation were determined, and according to the regularity of radon decay, the shielding rate can be calculated. Results: The results showed that radon shielding rate in underground construction remains generally stable with variation of time, and the actual relatively standard deviation was 3.95%. So the rapid determination and evaluation of radon preventing effect under special conditions in underground construction can be realized by taking shielding rate in a short time for the final shielding rate. Compared with those by the local static method in ground lab, the results were similar. Conclusion: This paper provided a prompt, accurate and practicable way for the evaluation of radon prevention in underground construction, having a certain reference value. (authors)

  17. Radon in the human life

    International Nuclear Information System (INIS)

    Thomas, J.

    1995-01-01

    Radon causes the utmost but controllable radiation exposure of the population. This is now clear, nearly hundred years after the discovery of radioactivity. Remediate and preventive activities have been stated with a complex approach using building engineering, geological sciences, physics and medicine. Despite of long experience in radon problems all these approaches need further development. (J.K.)

  18. Radon in the human life

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, J [State Office for Nuclear Safety, Prague (Czech Republic)

    1996-12-31

    Radon causes the utmost but controllable radiation exposure of the population. This is now clear, nearly hundred years after the discovery of radioactivity. Remediate and preventive activities have been stated with a complex approach using building engineering, geological sciences, physics and medicine. Despite of long experience in radon problems all these approaches need further development. (J.K.).

  19. Blower door method in radon diagnostics

    International Nuclear Information System (INIS)

    Fronka, A.; Moucka, L.

    2004-01-01

    The idea of the radon transfer factor is commonly presented as the ratio of the building indoor radon concentration to the subsoil radon concentration. Ventilation and the pressure field over the whole building envelope, which varies in a time over a very wide range even in the same building, poses a major problem. Therefore a new approach based on the controlled conditions determining the soil air infiltration was developed. Radon in soil gas infiltrates into the building indoor environment particularly through cracks and other leakages in the structure providing the building contact with its subsoil. The infiltration is driven by the air pressure difference on the two sides of the structure. The pressure difference is caused by the stack effect and its value ranges from 1-2 Pa in family houses to some tens of Pa in higher buildings. Unfortunately, the pressure difference is very unstable under normal conditions, being affected by a host of parameters such as the height of the building, distribution and geometry of leakages, outdoor-indoor temperature difference, etc. Wind direction and velocity of the wind plays a major role. In our research the blower door method was applied in combination with a monitoring of the indoor radon concentration. The indoor-outdoor pressure difference and the pressure difference at the two sides of the screen shutter of the blower door fan are also measured. The blower door ensures a constant, evaluable air exchange rate. The fan power is regulated to provide a stable pressure difference within the range of roughly 5-100 Pa. This approach provides very well defined conditions allowing us to apply a constant ventilation-constant radon supply model. In such circumstances the dynamical changes of radon concentrations are very fast, and therefore a unique continual radon monitor was applied. The radon supply rate is evaluated from the radon steady state of the time course of radon concentration. The dependence of the radon supply rate on

  20. Express method and radon gas measurement detector

    International Nuclear Information System (INIS)

    Khajdarov, R.A.; Khajdarov, R.R.

    2004-01-01

    The purpose of this work was to improve the activated charcoal adsorption method. The detector consisted of an electronic unit (200 mm x 180 mm x 80 mm) and a scintillation cell (a tube 200 mm long, 60 mm diam.). The electronic unit contained a power supply, amplifier, discriminator, timer, counter and indicator. The scintillation cell contained a zinc sulfide scintillator, photomultiplier, preamplifier, high voltage power supply and a 200 ml chamber above the scintillator. This chamber was intended to situate activated carbon fibrous absorber and air compressor. In this method, air is drawn through a filter to remove radon decay products and then through the activated carbon cloth by using a compressor. Sampling takes between 5 and 15 minutes. After the sampling, the cloth is heated for 5-10 sec up to 200-250 deg C by electric current passing through the fiber. Radon gas evaporates from the cloth and the device detects scintillation pulses. Owing to a high radon preconcentration factor (by adsorption of radon on the activated carbon cloth from 50-150 L of air of and evaporation into the small volume of the chamber), the detection limit of the method is 2-4 Bq/m 3 . Since the distance between the filter, cloth and scintillator is over 80 mm, the detector only measures radiation from radon without interference from the radon decay products, remaining in the filter and cloth

  1. Evaluation of the performance characteristics of radon and radon-daughter concentration measurement devices under controlled environmental conditions

    International Nuclear Information System (INIS)

    Pearson, M.D.

    1989-04-01

    The Technical Measurements Center (TMC) conducted a study to expose 10 radon and 7 radon-daughter concentration measurement devices in the DOE/GJPO Radon/Radon-Daughter Environmental Chamber for a series of 24 controlled-environment tests. The tests evaluated the devices' response to temperature, relative humidity, dew point, condensation-nuclei concentration, radon-daughter/radon equilibrium ratio, and non-uniform radon and radon-daughter concentration. Devices were evaluated for linear response as a function of concentration. In addition to response to environmental parameters, the evaluation included determining the utility of the devices in providing reasonable assurance of compliance with the radon and radon-daughter concentration standards for DOE remedial action programs. This reasonable assurance criterion is based on a coefficient of variation of 25 percent for devices deployed for year-long measurements and a coefficient of variation of 18 percent for devices deployed for intermittent sampling. 39 refs., 65 figs., 33 tabs

  2. Radon as a remedy - radiobiological and medical aspects, risk; Radon als Heilmittel - strahlenbiologische und medizinische Aspekte, Risiko

    Energy Technology Data Exchange (ETDEWEB)

    Schwarz, E.R.; Nuernberger, E.; Martignoni, K. [Inst. fuer Strahlenhygiene des Bundesamtes fuer Strahlenschutz, Oberschleissheim/Neuherberg (Germany)

    1995-09-01

    For years there have been controversial discussions about the benefit and risk of radon-balneo-therapy. This is particularly true where the inhalation of radon and its daughter products in curative galleries is concerned. Animal experiments and studies on uranium miners have clearly shown that the exposure with radon and its daughter products is connected with an additional risk for lung cancer. Findings on balneo-therapeutic mechanisms are, at best, incomplete and the topic of controversial discussions in radiobiology. This applies specifically to `hormesis` or `adaptive response`, as indicated in this context. Given the numerous reports of therapeutic results, there appear to be curative effects from radon-balneotherapy for special indications. (orig.) [Deutsch] Nutzen und Risiko der Radon-Balneotherapie werden seit Jahren widerspruechlich diskutiert. Dies gilt insbesondere fuer die Inhalation des Radons und seiner Folgeprodukte in Heilstollen. Tierversuche und Untersuchungen bei Uranbergleuten haben eindeutig gezeigt, dass mit der Exposition durch Radon und seinen Folgeprodukten ein zusaetzliches Lungenkrebsrisiko verbunden ist. Erkenntnisse zum Wirkungsmechanismus der Radon-Balneotherapie liegen allenfalls in Ansaetzen vor und werden in der Strahlenbiologie kontrovers diskutiert. Dies gilt insbesondere fuer die in diesem Zusammenhang angefuehrte `Hormesis` bzw. `Adaptive Response`. Geht man von den zahlreich berichteten therapeutischen Erfahrungen aus, so scheint es Hinweise auf Heileffekte der Radon-Balneotherapie fuer spezielle Indikationen zu geben. (orig.)

  3. Radon as a remedy - radiobiological and medical aspects, risk

    International Nuclear Information System (INIS)

    Schwarz, E.R.; Nuernberger, E.; Martignoni, K.

    1995-01-01

    For years there have been controversial discussions about the benefit and risk of radon-balneo-therapy. This is particularly true where the inhalation of radon and its daughter products in curative galleries is concerned. Animal experiments and studies on uranium miners have clearly shown that the exposure with radon and its daughter products is connected with an additional risk for lung cancer. Findings on balneo-therapeutic mechanisms are, at best, incomplete and the topic of controversial discussions in radiobiology. This applies specifically to 'hormesis' or 'adaptive response', as indicated in this context. Given the numerous reports of therapeutic results, there appear to be curative effects from radon-balneotherapy for special indications. (orig.) [de

  4. ERRICCA radon model intercomparison exercise

    International Nuclear Information System (INIS)

    Andersen, C.E.; Albarracin, D.; Csige, I.; Graaf, E.R. van der; Jiranek, M.; Rehs, B.; Svoboda, Z.; Toro, L.

    1999-04-01

    Numerical models based on finite-difference or finite-element methods are used by various research groups in studies of radon-222 transport through soil and building materials. Applications range from design of radon remediation systems to more fundamental studies of radon transport. To ascertain that results obtained with these models are of good quality, it is necessary that such models are tested. This document reports on a benchmark test organized by the EU project ERRICCA: European Research into Radon in Construction Concerted Action. The test comprises the following cases: 1) Steady-state diffusive radon profiles in dry and wet soils, 2) steady-state entry of soil gas and radon into a house, 3) time-dependent radon exhalation from a building-material sample. These cases cover features such as: soil heterogeneity, anisotropy, 3D-effects, time dependency, combined advective and diffusive transport of radon, flux calculations, and partitioning of radon between air and water in soil pores. Seven groups participated in the intercomparison. All groups submitted results without knowing the results of others. For these results, relatively large group-to-group discrepancies were observed. Because of this, all groups scrutinized their computations (once more) and engaged in follow-up discussions with others. During this debugging process, problems were indeed identified (and eliminated). The accordingly revised results were in better agreement than those reported initially. Some discrepancies, however, still remain. All in all, it seems that the exercise has served its purpose and stimulated improvements relating to the quality of numerical modelling of radon transport. To maintain a high quality of modelling, it is recommended that additional exercises are carried out. (au)

  5. Radon movement simulation in overburden by the 'Scattered Packet Method'

    International Nuclear Information System (INIS)

    Marah, H.; Sabir, A.; Hlou, L.; Tayebi, M.

    1998-01-01

    The analysis of Radon ( 222 Rn) movement in overburden needs the resolution of the General Equation of Transport in porous medium, involving diffusion and convection. Generally this equation was derived and solved analytically. The 'Scattered Packed Method' is a recent mathematical method of resolution, initially developed for the electrons movements in the semiconductors studies. In this paper, we have adapted this method to simulate radon emanation in porous medium. The keys parameters are the radon concentration at the source, the diffusion coefficient, and the geometry. To show the efficiency of this method, several cases of increasing complexity are considered. This model allows to follow the migration, in the time and space, of radon produced as a function of the characteristics of the studied site. Forty soil radon measurements were taken from a North Moroccan fault. Forward modeling of the radon anomalies produces satisfactory fits of the observed data and allows the overburden thickness determination. (author)

  6. Ventilation techniques and radon in small houses

    International Nuclear Information System (INIS)

    Keskinen, J.; Graeffe, G.; Janka, K.

    1988-01-01

    Indoor radon is the main cause of radiation exposure in Finland. The National Board of Health set the recommended concentration limits in 1986: an action level of 800 Bq/m 3 and a planning value of 200 Bq/m 3 for new buildings. The 800 Bq/m 3 concentration is estimated to be exceeded in 1.4% of the housing. This rather high number has motivated a number of studies concerning countermeasures against radon in existing houses. The purpose of this study was to find out possible remedial actions against radon using standard ventilation techniques. The ventilation rates were not increased over 0.71/h in order to have a realistic view about the possibilities of the state-of-the-art techniques. Special attention was given to methods which would be generally applicable to a large number of dwellings already existing. Results are reported of a pilot study with six small houses with established high radon concentrations

  7. Validity of various epidemiological approaches to assessing radon health risk

    International Nuclear Information System (INIS)

    Conrath, S.M.

    1990-01-01

    In this paper various epidemiologic study designs are defined and evaluated for their utility in assessing radon health risk. The strengths and limitations of these approaches are addressed. Common pitfalls and errors of epidemiologic method are delineated with examples of causes and remedies

  8. Predicting radon flux from uranium mill tailings

    International Nuclear Information System (INIS)

    Freeman, H.D.; Hartley, J.N.

    1983-11-01

    Pacific Northwest Laboratory (PNL), under contract to the US Department of Energy (DOE) Uranium Mill Tailings Remedial Action Project (UMTRAP) office, is developing technology for the design of radon barriers for uranium mill tailings piles. To properly design a radon cover for a particular tailings pile, the radon flux emanating from the bare tailings must be known. The tailings characteristics required to calculate the radon flux include radium-226 content, emanating power, bulk density, and radon diffusivity. This paper presents theoretical and practical aspects of estimating the radon flux from an uranium tailings pile. Results of field measurements to verify the calculation methodology are also discussed. 24 references, 4 figures, 4 tables

  9. Slovenian approach in managing exposure to radon at workplaces

    International Nuclear Information System (INIS)

    Vaupotic, J.

    2010-01-01

    Radon was surveyed in all the kindergartens and schools, major hospitals, water plants, wineries, spas, in a number of other public buildings, and karst caves with emphasis on the Postojna Cave (Slovenia). In addition to radon, also the concentration of radon short-lived decay products, equilibrium factor between radon and decay products, and unattached fraction of decay products have been monitored. Effective doses were calculated and used as a criterion to require remediation. (author)

  10. Another bogus radiation scare - radon in homes. Letter to the editor

    International Nuclear Information System (INIS)

    Cuttler, J.

    2012-01-01

    This article discusses Health Canada's research that radon in homes is causing unnecessary lung cancer deaths. Health Canada has carried out a cross-Canada survey of radon-concentrations in homes (Health Canada 2012). The aims of their study were to obtain an estimate of the proportion of the Canadian population living in homes, with radon gas levels above the guideline of 200 Bq/m to identify new areas of this health risk. Their results indicate that 6.9% of Canadians are in 3 such homes (similar to their 1970 results). The authors state that their results can be used by governments and health professionals to help prioritize radon outreach and education efforts, and testing and remediation. Their next step is to correlate radon level and home characteristics, and also develop radon mapping methods. Several sentences in the introduction link radon with lung cancer, based on early studies of uranium miners and later studies in homes. It is estimated that about 10% of all lung cancers worldwide are related to radon exposure.

  11. Protection of workers from radon

    International Nuclear Information System (INIS)

    Jacques, P.

    1992-01-01

    The TUC regards exposure to radon as one of a range of health hazards in industry which need to be controlled. In the case of radon the costs of control measures are very much lower than the costs of averting similar doses in the nuclear industry. All employers in the areas affected should be able to demonstrate that they have taken appropriate steps to determine the risks from radon and have introduced remedial measures where appropriate. The TUC considers it essential that trade union safety representatives should be fully involved and consulted about the problem. (Author)

  12. Radon decay product in-door behaviour - parameter, measurement method, and model review

    International Nuclear Information System (INIS)

    Scofield, P.

    1988-01-01

    This report reviews parameters used to characterize indoor radon daughter behavior and concentrations. Certain parameters that affect indoor radon daughter concentrations are described and the values obtained experimentally or theoretically are summarized. Radon daughter measurement methods are reviewed, such as, PAEC, unattached daughters, particle size distributions, and plateout measurement methods. In addition, certain radon pressure driven/diffusion models and indoor radon daughter models are briefly described. (orig.)

  13. [The methods of assessment of health risk from exposure to radon and radon daughters].

    Science.gov (United States)

    Demin, V F; Zhukovskiy, M V; Kiselev, S M

    2014-01-01

    The critical analysis of existing models of the relationship dose-effect (RDE) for radon exposure on human health has been performed. Conclusion about the necessity and possibility of improving these models has been made. A new improved version ofthe RDE has been developed. A technique for assessing the human health risk of exposure to radon, including the method for estimating of exposure doses of radon, an improved model of RDE, proper methodology risk assessment has been described. Methodology is proposed for the use in the territory of Russia.

  14. Lowering the UK domestic radon Action Level to prevent more lung cancers-is it cost-effective?

    International Nuclear Information System (INIS)

    Denman, A R; Groves-Kirkby, C J; Coskeran, T; Phillips, P S; Crockett, R G M; Tornberg, R

    2008-01-01

    Case studies have shown that radon gas can accumulate within domestic properties at sufficiently high levels that it can cause lung cancer, and recent studies have suggested that this risk remains significant below the UK domestic Action Level of 200 Bq m -3 . Raised radon levels can be reduced by engineering measures, and it has been shown that domestic radon remediation programmes in UK Affected Areas can result in reduced risks to the population and can be cost-effective. We consider here the benefits and costs of the domestic radon remediation programme in Northamptonshire, UK, and consider the implications for that programme of reducing the UK Action Level below its present value. A radon remediation programme based on an Action Level above 200 Bq m -3 will cost less and will target those most at risk, but will be less cost-effective and will lead to higher residual dose and greater risk of cancer in the remaining population. Reducing the Action Level below 200 Bq m -3 will prevent more cancers, but at significantly higher cost. It will also be less cost-effective, because remediation of a significant number of houses with moderate radon levels will provide only a modest health benefit to occupants. Overall, a completed radon remediation programme of the type implemented in Northamptonshire is most cost-effective for an Action Level between 200 and 300 Bq m -3 . The implications for future health policy are discussed

  15. Evaluation of the open vial method in the radon measurement

    International Nuclear Information System (INIS)

    Lopez del Rio, H.; Davila R, J. I.; Mireles G, F.

    2014-10-01

    The open vial method is a simple technique, under-utilized but that take advantage of the great radon solubility in organic solvents, therefore applies in the measurement of the radon concentration exhaled in soil. The method consists on the exposition to the gas radon of an open vial with scintillating solution. An integral mathematical model for indoors that describes the emanation processes and gas radon exhalation was developed, as well as the radon dissolution in the scintillation liquid, besides obtaining the characteristic parameters of the experimental system proposed for the radon concentration calculation exhaled by soils. Two experimental arrangements were designed with exposition cameras of 12 and 6 L and quantity of different soil. The open vial was prepared with a mixture of 8 ml of deionized water and 12 ml of scintillation liquid OptiPhase Hi Safe 3 in polyethylene vials; the measurements of the dissolved radon were carried out in scintillation liquid equipment. As a result, on average 2.0% of the exhaled radon is dissolved in the open vial and the dissolved fraction is independent of the experimental arrangement. Also was observed that the exposition time does not affect the radon dissolution significantly, in correspondence with the reported in the literature. (Author)

  16. Radon Measurement Proficiency (RMP) Program methods and devices

    International Nuclear Information System (INIS)

    Harrison, J.; Hoornbeek, J.; Jalbert, P.; Sensintaffar, E.; Hopper, R.

    1991-01-01

    The US EPA developed the voluntary Radon Measurement Proficiency Program in 1986 in response to a Federal and State need for measurement services firms to demonstrate their proficiency with radon measurement methods and devices. Since that time, the program has set basic standards for the radon measurement industry. The program has grown dramatically since its inception. In 1986, fewer than 50 companies participated in the program. By 1989, more than 5,000 companies were participating. Participants represent firms with an analytical capability as well as firms that rely upon another firm for analysis service. Since the beginning of the RMP Program, the Agency has learned a great deal about radon measurement methods and devices. This paper reviews the measurement devices used in the program and what the EPA has learned about them since the program's inception. Performance data from the RMP Program are used to highlight relevant findings

  17. Utilisation of an Air-conditioning System to Control the Levels of Radon and Radon Progeny in a Workplace Environment

    International Nuclear Information System (INIS)

    Marley, F.

    2000-01-01

    From long-term real-time radon and radon progeny measurements taken in a relatively large retail store, cyclical patterns were evident, which were found to relate to the overriding influence of the timed air-conditioning system. Concentration of radon, radon progeny and the variability of F factor were found to depend significantly on the intermittent operation of this ventilation-air-conditioning system. After pressure equalisation remedial measures proved ineffective, the air-movement system was utilised to reduce the levels of radon and radon progeny to well within established norms applicable during working hours. It is demonstrated that the average levels for radon and radon progeny are reduced in absolute terms. This amounted to less than 12% of the general level, during designated work periods. Where air movement systems are already installed, as well as other circumstances, their regulation provides an economical solution to meeting legal and other standards for radon in the workplace. (author)

  18. Radon in the workplace

    International Nuclear Information System (INIS)

    Scivyer, C.R.; Gregory, T.J.

    1995-01-01

    This Guide has been prepared for the Health and Safety Executive (HSE) by the Building Research Establishment (BRE). Following the guidance is not compulsory and you are free to take other action. However if you do follow the guidance you will normally be doing enough to comply with the law. Health and Safety Inspectors seek to secure compliance with the law and may refer to this guidance as illustrating good practice. In the past, concern about exposure of employees to radon has largely centred on the mining environment. In recent times, with increased knowledge and mapping of radon levels in homes, attention has increasingly turned to radon exposure in buildings used for work purposes. Now there is a considerable fund of information to show that employees in some buildings can receive very significant radiation doses from radon. Surveys show that levels of radon tend to be higher in buildings with small rooms, such as offices rather than larger factory and warehouse constructions. The particular problem is that the nature of the work process gives no clue as to the radon hazard that may exist, and the employer may be unaware of its presence and how to deal with it. This Guide is aimed principally at employers and those who control buildings used for work purposes, or their representatives. It offers guidance on practical measures for reducing radon levels in workplaces. The guidance should also be of interest and assistance to those, such as surveyors and builders, concerned with specifying and carrying out the necessary remedial measures. Advice is provided for the majority of building types and construction situations likely to be encountered in larger non-domestic buildings. For buildings where construction is similar to that found in dwellings the guidance published by BRE on remedial measures for dwellings should be used. BRE prepared this Guide with assistance from the National Radiological Protection Board (NRPB) and Cornwall County Council under contract

  19. A study of radon indoor concentration; Un estudio de concentracion de radon intramuros

    Energy Technology Data Exchange (ETDEWEB)

    Pena, P.; Ruiz, W.; Segovia, N.; Ponciano, G. [ININ, Gerencia de Ciencias Ambientales, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    2000-07-01

    It was realized a study of radon concentration in houses of Mexico City and in a laboratory of the Nuclear Centre of Salazar, State of Mexico. The radon determination in air was realized with solid nuclear track detectors and with Honeywell and Alpha guard automatic equipment. The results show that the majority of houses have values under 148 Bq/m{sup 3} obtaining some housings with upper values located in the Lomas zone. A study in smokers houses and another of controls showed very similar distributions. It was studied the day time fluctuations finding that radon increases considerably during the dawn. Some upper values obtained in a laboratory of the Nuclear Centre were remedied with ventilation. (Author)

  20. Training and accreditation for radon professionals in Sweden

    International Nuclear Information System (INIS)

    Mjoenes, L.; Soederman, A.-L.

    2004-01-01

    Radon training courses and seminars on radon have been arranged in Sweden since the early 1980s. A commercial educational company initiated the first regular training courses in 1987. Up to 1990 about 400 persons had attended courses in radon measurement and radon mitigation methods. In 1991 the training programme was taken over by the Swedish Radiation Protection Authority, SSI. Today SSI's Radon Training Programme comprises three different two-day courses, a Basic Radon Course and two continuation courses: Radon Measurements and Radon in Water. Until 2003 SSI also arranged courses about Radon Remedial Measures and Radon Investigation and Risk Map Production. The courses are arranged twice a year. Altogether, about 750 municipal environmental health officers and technicians from private companies have been educated in the SSI training programme between 1991 and 2003. The continuation courses are completed with an examination, consisting of a theoretical test. The names of the persons who pass are being published in a list that is found on the SSI web site. Since no certification system is currently in place for radon professionals in Sweden, this list helps people who need to get in contact with radon counsellors to find one in their area and is used by authorities as well as private house-owners. Since 1991 it has been possible to obtain accreditation for measurements of indoor radon in Sweden and since 1997, also for measurements of radon in water. Although accreditation is voluntary in Sweden, accredited laboratories perform most measurements, both for indoor air and water. Passing the examination in the SSI training courses is a condition for accreditation. The Swedish Board for Accreditation and Conformity Assessment, SWEDAC, is in charge of the accreditation. So far, three major companies have obtained accreditation for measurement of indoor radon and four have been accredited for measurements of radon in water

  1. Removing efficiency of radon from water by different methods

    International Nuclear Information System (INIS)

    Muellerova, M.; Holy, K.; Gulasova, Z.; Polaskova, A.

    2008-01-01

    In this contribution problem of radon removing from water samples by different methods was tested. Lowest efficiency of deemanation was achieved at tossing of water from one vessel into the other. For increasing of efficiency deemanation of radon use of needle-bath principle was also used. Low efficiency deemanation was found at trapping of radon from sample of water by toluene (83 ± 5) %, too. Reversal highest efficiency deemanation of radon from water was reached at aerating by argon (95 ± 6)%. It is shown, that reduction of volume activity of radon in water under 0.1 Bq/dm l - 3 is big problem. Suppression of this limit will claim use of more completion and sophistic approaches. (author)

  2. An overview of Ireland's National Radon Policy

    International Nuclear Information System (INIS)

    Long, S.; Fenton, D.

    2011-01-01

    In Ireland radon is a significant public health issue and is linked to 150-200 lung cancer deaths each year. Irish National Radon Policy aims to reduce individual risk by identifying and remediating buildings with high radon concentrations and also to reduce collective dose through radon prevention as required by revised building regulations. Achievements to date are significant and include the completion of the National Radon Survey, the testing of every school in Ireland, the on-going testing of social housing, collaboration between the public health and radiation protection authorities and the inclusion of radon in inspections of workplaces. However, this work now needs to be drawn together centrally to comprehensively address the radon problem. The RPII and the relevant central governing department, the Dept. of Environment, Heritage and Local Government are currently working to constitute a group of key experts from relevant public authorities to drive the development of a National Radon Control Strategy. (authors)

  3. Radon in Irish schools: the results of a national survey

    International Nuclear Information System (INIS)

    Synnott, H; Hanley, O; Fenton, D; Colgan, P A

    2006-01-01

    This paper presents the results of a survey of radon concentrations in Irish primary and post-primary schools. The objective of this survey was to assess the distribution of radon in Irish schools and to identify those requiring remedial work to reduce radon exposure to children and staff. All primary and post-primary schools were invited to participate in the survey. Indoor radon concentrations were measured during the academic year using integrating passive alpha track-etch detectors with a measurement period from three to nine months. The survey was carried out on a phased basis from 1998 to 2004 and is one of the most comprehensive of its kind undertaken in Europe. Measurements were completed in 38 531 ground floor classrooms and offices in 3826 schools, representing over 95% of the approximate 4000 primary and post-primary schools in Ireland. Of these, 984 schools had radon concentrations greater than 200 Bq m -3 in 3028 rooms and 329 schools had radon concentrations in excess of 400 Bq m -3 in 800 rooms. The average radon concentration in schools was 93 Bq m -3 . This results in an annual average effective dose to an Irish child from exposure to radon of 0.3 mSv per year, assuming that the long-term radon concentration is equal to the radon concentration present during the working hours and that the annual average occupancy is 1000 h per year. A programme of remediation of schools with radon concentrations above 200 Bq m -3 has been put in place

  4. Control methods of radon and its progeny concentration in indoor atmosphere

    International Nuclear Information System (INIS)

    Ramachandran, T.V.; Subba Ramu, M.C.

    1990-01-01

    Exposure to radon-222 and its progeny in indoor atmosphere can result in significant inhalation risk to the population particularly to those living in houses with much higher levels of Rn. There are three methods generally used for the control of Rn and its progeny concentration in the indoor environment: (1) restricting the radon entry, (2) reduction of indoor radon concentration by ventilation or by aircleaning and (3) removal of airborne radon progeny by aerosol reduction. Prominent process of radon entry in most of the residence appears to be the pressure driven flow of soil gas through cracks or through other openings in the basements slab or subfloor. Sealing off these openings or ventilation of the slab or subfloor spaces are the methods of reducing the radon entry rate. Indoor radon progeny levels can also be reduced by decreasing the aerosol load in the dwellings. The results of a few experiments carried out to study the reduction in the working level concentration of radon, by decreasing the aerosol load are discussed in this paper. (author). 9 tabs., 8 figs., 37 refs

  5. Remedial Action Plan and site design for stabilization of the inactive uranium mill tailings site at Gunnison, Colorado

    International Nuclear Information System (INIS)

    1992-10-01

    Diffusion coefficients for radon gas in earthen materials are required to design suitable radon-barrier covers for uranium tailings impoundments and other materials that emit radon gas. Many early measurements of radon diffusion coefficients relied on the differences in steady-state radon fluxes measured from radon source before and after installation of a cover layer of the material being tested. More recent measurements have utilized the small-sample transient (SST) technique for greater control on moistures and densities of the test soils, greater measurement precision, and reduced testing time and costs. Several of the project sites for the US Department of Energy's Uranium Mill Tailings Remedial Action (UMTRA) Program contain radiologically contaminated subsurface material composed predominantly of cobbles, gravels andsands. Since remedial action designs require radon diffusion coefficients for the source materials as well as the cover materials, these cobbly and gravelly materials also must be tested. This report contains the following information: a description of the test materials used and the methods developed to conduct the SST radon diffusion measurements on cobbly soils; the protocol for conducting radon diffusion tests oncobbly soils; the results of measurements on the test samples; and modifications to the FITS computer code for analyzing the time-dependent radon diffusion data

  6. Calculation of radon concentration in water by toluene extraction method

    Energy Technology Data Exchange (ETDEWEB)

    Saito, Masaaki [Tokyo Metropolitan Isotope Research Center (Japan)

    1997-02-01

    Noguchi method and Horiuchi method have been used as the calculation method of radon concentration in water. Both methods have two problems in the original, that is, the concentration calculated is changed by the extraction temperature depend on the incorrect solubility data and the concentration calculated are smaller than the correct values, because the radon calculation equation does not true to the gas-liquid equilibrium theory. However, the two problems are solved by improving the radon equation. I presented the Noguchi-Saito equation and the constant B of Horiuchi-Saito equation. The calculating results by the improved method showed about 10% of error. (S.Y.)

  7. Development of Radon-222 as Natural Tracer for Monitoring the Remediation of NAPL in the Subsurface

    International Nuclear Information System (INIS)

    Davis, Brian M.; Semprini, Lewis; Istok, Jonathan

    2003-01-01

    Naturally occurring 222-radon in ground water can potentially be used as an in situ partitioning tracer to characterize dense nonaqueous phase liquid (DNAPL) saturations. The static method involves comparing radon concentrations in water samples from DNAPL-contaminated and non-contaminated portions of an aquifer. During a push-pull test, a known volume of test solution (radon-free water containing a conservation tracer) is first injected (''pushed'') into a well; flow is then reversed and the test solution/groundwater mixture is extracted (''pulled'') from the same well. In the presence of NAPL radon transport is retarded relative to the conservative tracer. Assuming linear equilibrium partitioning, retardation factors for radon can be used to estimate NAPL saturations.The utility of this methodology was evaluated in laboratory and field settings

  8. Decommissioning/closeout of Malargue site: measurement of radon daughter

    International Nuclear Information System (INIS)

    Avila Cadena, Guadalberto

    2000-01-01

    In Malargue complex there are about 700,000 mt of uranium tailings disposed off during 32 years of operation of the Malargue facility. The objective of the Malargue Site is to undertake the necessary actions to execute remediation programs. A summary of measurements of concentrations of radon daughter taken in different buildings of the city and in the field shows the influence of radon source. The results obtain for concentrations of radon daughter indicate that they do not differ significantly between each others. The environmental remediation of uranium mill tailings at Malargue Site is a requirement of Nuclear Regulatory Authority (NRA) and of the Mendoza province and a commitment to reduce the doses as low as reasonably achievable, social and economic factors being taken into account (ALARA concept). (author)

  9. The health benefits and cost effectiveness of the radon mitigation programme in NHS properties in Northamptonshire

    International Nuclear Information System (INIS)

    Denman, A.R.; Parkinson, S.; Barker, S.P.; Phillips, P.

    1997-01-01

    A comprehensive radon remediation programme in Nahs properties in Northamptonshire, where 11 100 staff are employed working on 83 separate sites, has been in progress since 1992, and has resulted in many locations with raised radon levels being identified and re mediated. This paper considers the dose saving achieved and costs of the remediation to derive a value for the cost-effectiveness of the programme. A value of 84 000 per Man-Sievert of annual dose reduction was obtained, which is around half the figure calculated by the NRPB in its recent initiative to reduce patient doses from dental x-rays in the UK, based on cost-benefit analysis. Thus similar comprehensive radon remediation programmes in any workplace in Radon Affected Areas can be justified. The cost of this workplace programme is, however, a factor of about 4 times more expensive than the theoretical estimates for domestic radon mitigation programmes found in the literature, and the reasons for this difference are considered. (author)

  10. Research on radon flux reduction from uranium mill tailings

    International Nuclear Information System (INIS)

    Overmyer, R.F.; Thamer, B.J.; Nielson, K.K.; Rogers, V.C.

    1980-01-01

    Radon flux reduction from tailings may be accomplished by the use of an impermeable cover to contain the radon until it decays (half life is 2.8 days). The use of a thick, relatively impermeable cover can attenuate radon flux because a large fraction of the radon would decay before it diffuses through the cover into the atmosphere. This method of reducing radon flux may require soil cover thicknesses on the order of 10 feet. In some locations, obtaining 10 feet of soil to cover 200 acres of tailings may be difficult or may lead to other significant environmental impacts. The Department of Energy is sponsoring research to identify alternatives to thick soil covers for reducing radon flux from uranium tailings to meet the forthcoming standards. The two most effective and practical materials tested thus far are Calcilox and asphalt emulsion. Currently, asphalt emulsions are being tested at the Grand Junction tailings pile in Grand Junction, Colorado, by Battelle Pacific Northwest Laboratory. Other asphalt formulations, such as foamed asphalt that requires less water than asphalt emulsions, may be practical and will be tested this year. Some sulfur-based materials and sulfur-extended asphalt also appear promising and will be tested for effectiveness in reducing radon flux. It is also important to investigate methods of applying various stabilizers to inactive tailings piles in various physical conditions of moisture content, and physical stability. Finally, since the EPA standards for remedial action at tailings piles are stated in terms of radon flux, it is important that radon flux measurements be standardized so that reliable flux measurements can be obtained and directly compared among various laboratories

  11. Swiss radon programme 'RAPROS'

    International Nuclear Information System (INIS)

    Zeller, W.

    1992-03-01

    The results of the five-year radon research program RAPROS presented in this report, allow for scientifically valid statements on the origin of elevated levels of indoor radon in Switzerland. These results form a basis for recommendations and for actions to be taken. Indoor radon concentrations have been measured in more than 4000 living-rooms and 2000 basements; a sampling density of about 0.2% of the Swiss housing stock. According to these measurements radon leads to an estimated average annual effective dose of 2 milli-Sievert, although in some regions the annual dose may be much higher. Extrapolation of the existing data shows that in about 10'000 Swiss houses radon may exceed 1000 Bq/m 3 . For these houses remedial actions are recommended. There seems to be no radon problem in the large cities in the Swiss Plateau. High indoor radon concentrations in Switzerland are due to the soil beneath the buildings. Data from the study indicated that the most important soil characteristic influencing indoor radon concentrations was its gas permeability. Because natural ventilation in a heated house creates a slight underpressure in the lower levels with respect to surrounding soils, radon is driven from the soil into the building. Weatherization of the houses to reduce energy consumption had in most cases no effect on the indoor radon concentrations. Radon from tap water or from building materials does not contribute significantly to indoor radon levels in Switzerland. The high levels in the Jura Mountains are thought to be associated with karstic limestone bedrock. Several houses within Switzerland have now been modified to reduce radon levels. The most successful mitigation technique combined forced-air ventilation with tightening of the basement to decrease or prevent air infiltration from the soil. (author) figs., tabs., refs

  12. Year-long comparison of two techniques to monitor outdoor radon concentrations at Shiprock, New Mexico

    International Nuclear Information System (INIS)

    Novak, E.F.

    1988-08-01

    The US Department of Energy (DOE) Office of Remedial Action and Waste Technology established the Technical Measurements Center (TMC) at the DOE Grand Junction Projects Office (GJPO) in Grand Junction, Colorado, to standardize, calibrate, and compare measurements made in support of DOE remedial action programs. Outdoor radon concentration measurements were made by the TMC in Shiprock, New Mexico, to compare two different methods of measuring radon in an attempt to determine the feasibility of using passive alpha-track detectors to assess the adequacy of remedial action undertaken at the Shiprock uranium mill tailings pile. The results of the first three quarters of monitoring have been detailed in previous reports. An analysis of the data from the fourth quarter of monitoring at Shiprock reveals a somewhat poorer correlation between the two sets of measurements than was seen in the third quarter of this study, but a better correlation than was found for the first and second quarters. The results of a nearly year-long exposure of alpha-track detectors were in much better agreement with the annual-average results of the second measurement method than were any of the quarterly results. The results of a calibration exposure of several alpha-track detectors in an environmentally controlled radon chamber differed significantly from the detector manufacturer's calibrations. The most significant conclusion is that alpha-track detectors require a year-long exposure to provide a reliable estimate of the annual-average outdoor radon concentration. Annual averages calculated from quarterly exposures are more prone to errors occurring during the track-counting process. 7 refs., 5 figs., 5 tabs

  13. Management of the radon-related risk. Guide for local authorities. Guide for employers

    International Nuclear Information System (INIS)

    Struillou, Yves; Gupta, Olivier

    2017-01-01

    A first guide aims at being an aid to decision by specifying obligations of local authorities as owners of buildings open to public or as employers, but also at being a support for their health and social actions in terms of information on radon risk in housing. After a presentation of the risk related to radon (health risks, radon propagation, regulatory areas concerned by radon risk management in France), the report indicates the various obligations and mandatory actions for local authorities as building owner and as employer, and actions to be undertaken for existing and new buildings. Technical sheets are provided regarding radon detection, certifications, simple actions, technical diagnosis, remediation works, efficiency control of technical solutions, expert in radiation protection. The second guide aims at being an aid to decision by specifying obligations for employers in terms of management of radon-related risk to which some workers might be exposed, and at providing some good practice recommendations. After a presentation of the risk related to radon (health risks, radon propagation, regulatory areas concerned by radon risk management in France), the report addresses how to organise the radon-related risk management, how to measure radon in work places, how to interpret results and which actions to undertake. Technical sheets are provided regarding radon detection, certifications, simple actions, technical diagnosis, remediation works, efficiency control of technical solutions, expert in radiation protection

  14. Cost effectiveness of reducing radon exposure in Spanish dwellings

    International Nuclear Information System (INIS)

    Colgan, P.A.; Gutierrez, J.

    1996-01-01

    Published information on the distribution of radon levels in Spanish single family dwellings is used to evaluate the cost-effectiveness of three different intervention scenarios: remediation of existing dwellings, radon proofing of all future dwellings and the targetting of areas with higher than average indoor radon concentrations. Analysis is carried out on the basis of a Reference Level of 400 Bq m -3 for the existing housing stock and 200 Bq m -3 for new dwellings. Certain assumptions are made about the effectiveness and durability of the measures applied and annualised costs are used to calculate the costs per lung cancer death averted. The results reveal that targetting future housing is a more cost-effective option than remediation of existing dwellings with radon concentrations above the Reference Level -the costs per lung cancer death averted are typically $145000. In high-risk areas, these costs can be considerably less, depending on the percentage of dwellings expected to exceed the Reference Level and the average savings in exposure as a result of the intervention. The costs of intervention to reduce lung cancer deaths following exposure to radon compare favourably with those of other health programmes in other countries. (Author)

  15. A cost-effectiveness analysis of radon protection methods in domestic properties: a comparative case study in Brixworth, Northamptonshire, UK

    International Nuclear Information System (INIS)

    Coskeran, Thomas; Denman, Antony; Phillips, Paul; Tornberg, Roger

    2006-01-01

    Building regulations in the UK have since 1992 required that radon-proof membranes be installed in new domestic properties to protect residents against the adverse effects of radon. This study compares the cost-effectiveness of the current regulatory regime with an alternative that would entail new properties being tested for radon after construction, and being remediated if necessary. The alternative regime is found to be more cost-effective for a sample of properties in Brixworth, Northamptonshire, UK. For this regime, the central estimate of cost per quality-adjusted life-year gained, the measure of cost-effectiveness used, is Pounds 2869 compared to Pounds 6182 for installing membranes, results suggesting a case for re-examining the current regulations on radon protection in new properties. Pilot studies will, however, be needed to consider how different means of protecting residents of new properties against radon might operate in practice and to provide improved evidence on their relative cost-effectiveness

  16. A Radon Micro Study of Salthill, Galway

    International Nuclear Information System (INIS)

    Boyle-Tobin Ann

    2006-01-01

    This project presents a study of radon gas, when it enters from the ground into the built environment. In order to further inform the present body of knowledge on this potentially dangerous gas, a radon micro study is carried out in the area of Salthill, Galway. A total of 51 households are measured for radon. The results indicate a high variation in the levels recorded, with over a third of the houses measuring above the national safe standard of 200 becquerels per cubic meter, with a small percentage of houses exhibiting very high levels. The results are spatially analysed against the local geology, as radon is a by-product of the breakdown of uranium in rocks. Householders' knowledge and awareness of radon is explored to inform the reasons why more people are not testing their homes for radon, and not installing remedial measures when high levels are detected. The findings indicate significant gaps in householders' knowledge of radon. A certain complacency is noted, which may indicate that people still do not recognise a need to know about this invisible threat. As ways to encourage further testing and remediation levels are equally explored, the government is viewed to play a central role in these processes through partial state funding. Further evidence supports continued and more effective and widespread advertising of radon issues, through all types of media, with emphasis at local level. Incidents of lung cancer and lung disease of long term residents are recorded in an attempt to find out if there is a correlation between them. The results indicate no correlation; however, not all households could participate in this part of the survey as it was limited to long-term residents only

  17. Study on the measurement method of diffusion coefficient for radon in the soil. 2

    International Nuclear Information System (INIS)

    Iida, Takao

    2000-03-01

    To investigate radon behavior in the soil at Ningyo Pass, the radon concentrations in the soil and the radon exhalation rate from soil surface were measured by four continuous soil radon monitoring systems, soil gas sampling method, and accumulation method. The radon concentrations in the soil measured with continuous soil radon monitoring systems varied form 5000 Bq·m -3 to 15000 Bq·m -3 at 10 cm to 40 cm depth. On the other hand, the radon concentrations measured by soil gas sampling method was 15000 Bq·m -3 at 15 cm depth. The accumulation method gives the vales of 0. 36∼0.68 Bq·m -2 ·s -1 for radon exhalation rate from soil surface. To simulate the radon transport in soil, the following parameters of the soil are important: radon diffusion coefficients, dry density, wet density, soil particle density, true density, water content and radium concentration. The measured radon diffusion coefficients in the soil were (1.61±0.09)x10 -6 m 2 s -1 , (8.68±0.23)x10 -7 m 2 s -1 ∼ (1.53±0.12)x10 -6 m 2 s -1 and (2.99±0.32)x10 -6 m 2 s -1 ∼ (4.39±0.43)x10 -6 m 2 s -1 for sandy soils of the campus of Nagoya University, Tsuruga peninsula, and Ningyo Pass, respectively. By using these parameters, the radon transport phenomena in the soil of two layers were calculated by analytical and numerical methods. The radon profile calculated by numerical method agrees fairly well with measured values. By covering of 2 m soil, the radon exhalation rate decreases to 1/4 by analytical method, and 3/5 by numerical method. The covering of normal soil is not so effective for reducing the radon exhalation rate. (author)

  18. Environmental Radon Gas and Degenerative Conditions An Overview

    International Nuclear Information System (INIS)

    Groves-Kirkby, C.J.; Denman, A.R.; Woolridge, A.C.; Phillips, P.S.; Phillips, C.

    2006-01-01

    Radon, a naturally occurring radioactive gas, has variable distribution in the environment as a decay product of uranium occurring in a wide range of rocks, soils and building materials. Although radon dissipates rapidly in outdoor air, it concentrates in the built environment, and inhalation of 222 Rn and its progeny 218 Po and 214 Po is believed to provide the majority of the radioactive dose to the respiratory system. While the connection between radon and lung cancer has long been recognised and investigated, recent studies have highlighted potential links between radon and other conditions, among them Multiple Sclerosis, Alzheimer and Parkinson Diseases, and Paget Disease of Bone. A strong case exists for clarifying the relationship between radon and these other conditions, not least since radon remediation to reduce lung cancer may conceivably have additional benefits hitherto unrecognized. The present status of the postulated links between environmental radon gas and degenerative conditions is reviewed, and recommendations for further research into levering current anti-radon campaigns are made. (authors)

  19. Method for radon measurement in the subsoil in geothermal prospectus

    International Nuclear Information System (INIS)

    Balcazar G, M.

    1991-02-01

    The present formless describe the technique for radon measurement in the underground, being able to be used as an additional study in the geothermal prospecting. This methodology has been developed in the National Institute of Nuclear Research of Mexico using a film of cellulose nitrate to detect those emanated alpha particles, by the Rn (222). By means of the trace account in this films its settle down the present radon levels in the underground. The present method thinks about as an alternating one to overcome in it leaves the limitations found in the development of the methodology using a radon emanometer ETR-1, of the trade mark SCINTREX. The radon detected by plastics is also an integral method of measuring in a geothermal field that avoids the problems of variations of radon to pluvial precipitations and barometric variations. These variations affect the results strongly when it is used the punctual sampler as it is the ETR-1. (Author)

  20. Radon legislation and national guidelines

    Energy Technology Data Exchange (ETDEWEB)

    Aakerblom, G

    1999-07-01

    50-500 Bq/l for public waters and 200-1000 Bq/l for private water supplies. 4 EU member states and 11 non-EU European countries have reference levels for the concentration of radioactive elements in building materials. 8 European countries have guidelines regarding radon at city planning and 13 have mapped the radon risk in their countries. It is essential to the work against radon and to future reduction of radon concentrations in dwellings and workplaces that the national states issue recommendations, regulations, directives or laws on radon limits and building practices. In order to have a significant effect on the radon situation, the questionnaire responses show that radon reference levels and regulations must be enforced or very little progress is achieved. Extensive measurement and research programs have been carried out in many in countries. Heretofore, only those countries with enforced regulations have had successful programs, resulting in remedial actions in more than 10,000 buildings. The only exception is USA, which concentrated on extensive information media campaigns on radon and the training of large numbers of contractors to perform measurements and remedial measures.

  1. Radon legislation and national guidelines

    International Nuclear Information System (INIS)

    Aakerblom, G.

    1999-07-01

    -500 Bq/l for public waters and 200-1000 Bq/l for private water supplies. 4 EU member states and 11 non-EU European countries have reference levels for the concentration of radioactive elements in building materials. 8 European countries have guidelines regarding radon at city planning and 13 have mapped the radon risk in their countries. It is essential to the work against radon and to future reduction of radon concentrations in dwellings and workplaces that the national states issue recommendations, regulations, directives or laws on radon limits and building practices. In order to have a significant effect on the radon situation, the questionnaire responses show that radon reference levels and regulations must be enforced or very little progress is achieved. Extensive measurement and research programs have been carried out in many in countries. Heretofore, only those countries with enforced regulations have had successful programs, resulting in remedial actions in more than 10,000 buildings. The only exception is USA, which concentrated on extensive information media campaigns on radon and the training of large numbers of contractors to perform measurements and remedial measures

  2. Remedial action of radium contaminated residential properties

    International Nuclear Information System (INIS)

    White, D.; Eng, J.

    1986-01-01

    Since November 1983, the New Jersey Department of Environmental Protection (NJDEP) and the US Environmental Protection Agency (USEPA) have been in the process of identifying properties in Montclair, Glen Ridge and West Orange, New Jersey, which were built over radium contaminated soil landfilled areas. Elevated indoor radon concentrations prompted the Centers for Disease Control (CDC) to issue a health advisory which included permanent remediation of radon progeny levels in excess of 0.02 Working Levels within two years of discovery. In order to expedite remedial action, NJDEP undertook a ten million dollar cleanup program. Remedial Action at the 12 residential properties encountered some unanticipated problems despite the efforts of numerous government agencies and their contractors to characterize the contamination as much as possible prior to remediation. Some of the unanticipated issues include contamination from other radionuclides, underestimation of removal volumes, and controversy over the transportation and disposal of the radium contaminated soil at a commercial facility in Nevada. This paper will review the approach taken by NJDEP to the remedial action for radium contaminated soil, discuss some of the issues encountered during the remedial action, and provide post remedial action data

  3. Evaluation of the open vial method in the radon measurement; Evaluacion del metodo del vial abierto en la medicion de radon

    Energy Technology Data Exchange (ETDEWEB)

    Lopez del Rio, H.; Davila R, J. I.; Mireles G, F., E-mail: hlopezdelrio@hotmail.com [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico)

    2014-10-15

    The open vial method is a simple technique, under-utilized but that take advantage of the great radon solubility in organic solvents, therefore applies in the measurement of the radon concentration exhaled in soil. The method consists on the exposition to the gas radon of an open vial with scintillating solution. An integral mathematical model for indoors that describes the emanation processes and gas radon exhalation was developed, as well as the radon dissolution in the scintillation liquid, besides obtaining the characteristic parameters of the experimental system proposed for the radon concentration calculation exhaled by soils. Two experimental arrangements were designed with exposition cameras of 12 and 6 L and quantity of different soil. The open vial was prepared with a mixture of 8 ml of deionized water and 12 ml of scintillation liquid OptiPhase Hi Safe 3 in polyethylene vials; the measurements of the dissolved radon were carried out in scintillation liquid equipment. As a result, on average 2.0% of the exhaled radon is dissolved in the open vial and the dissolved fraction is independent of the experimental arrangement. Also was observed that the exposition time does not affect the radon dissolution significantly, in correspondence with the reported in the literature. (Author)

  4. Seismic and radon monitoring of Algocen site at Elliot Lake

    International Nuclear Information System (INIS)

    1981-03-01

    Remedial works to reduce radon/radon daughters to acceptable levels in houses in Elliot Lake have been going on for the last three years under the Atomic Energy Control Board (AECB) remedial action program. In December 1978, a routine inspection of treated houses showed extensions to cracks already filled, and the opening up of filled cracks. The homeowners attributed this to the blasting operations for building construction which were going on in town at that time. This prompted the need to monitor any subsequent major scale blasting in the town and to record the damages in nearby houses. This report presents the results of monitoring one such major blasting operation which was carried out between March 1979 and June 1979 for the building of the Algocen Shopping Mall east of Hutchison Avenue. The AECB were concerned about the possible damage to the houses along Hutchison Avenue which had already received remedial treatment to prevent the entry of radon gas, and authorized DSMA/Acres to record the level of vibrations and damages in these houses during the blasting period. (author)

  5. New method of reducing radon levels in homes

    International Nuclear Information System (INIS)

    Khaydarov, R.A.; Gapurova, O.U.; Khaydarov, R.R.

    2006-01-01

    Full text: Radon is a naturally occurring gas seeping into homes and underground structures (buildings, tunnels, hangars, garages, etc.) from the surrounding soil through walls, floor, etc. and emanating from construction materials such as concrete, granite, etc. The level of radon is especially great in regions with the heightened content of uranium in soil and water and with geological breaks of the earth's crust. Concentrations of uranium higher than 10 g per ton of soil have been found in 14 percent of territory of Uzbekistan. As a result, for instance, concentration of radon 10-100 times exceeds the regulation level in 14 percent of premises in Tashkent, 41 percent of premises in Almalik town and 44 percent in Yangiabad town. The purpose of this work was creating a method to reduce concentration of radon gas in buildings and underground structures. We suppose that the most effective technique is a treatment of walls, floors, etc. of basement and underground structures by special chemicals which seal micropores inside the construction materials. Sealing the pores stops radon diffusion and in addition, it blocks another radon pathway - water migration and emanation from concrete, gypsum or other construction materials. In the paper polymeric silico organic compounds are investigated and selected as the chemicals to prevent radon seeping indoors. Gas (air, Ar, Rn 222, H 2 O) permeability of concrete and gypsum after treatment by chemicals has been examined. Influence of types of cement and sand, preliminary treatment by different chemicals, different types of polymeric silico organic compounds, time between treatments, moisture of concrete, time between preparation of chemicals and treatment of concrete (aging of chemicals), time between treatment of concrete and testing (aging of treated concrete) have been examined. Surfaces of the samples were treated by spray. Experiments have shown that chosen method of treatment of the construction materials allows reducing

  6. IN-SITU MEASURING METHOD OF RADON AND THORON DIFFUSION COEFFICIENT IN SOIL

    Directory of Open Access Journals (Sweden)

    V.S. Yakovleva

    2014-06-01

    Full Text Available A simple and valid in-situ measurement method of effective diffusion coefficient of radon and thoron in soil and other porous materials was designed. The analysis of numerical investigation of radon and thoron transport in upper layers of soil revealed that thoron flux density from the earth surface does not depend on soil gas advective velocity and varies only with diffusion coefficient changes. This result showed the advantages of thoron using versus radon using in the suggested method. The comparison of the new method with existing ones previously developed. The method could be helpful for solving of problems of radon mass-transport in porous media and gaseous exchange between soil and atmosphere.

  7. Uranium mill tailings remedial action technology

    International Nuclear Information System (INIS)

    Hartley, J.N.; Gee, G.W.

    1984-01-01

    The uranium milling process involves the hydrometallurgical extraction of uranium from ores and the resultant generation of large quantities of waste referred to as tailings. Uranium mill tailings have been identified as requiring remediation because they contain residual radioactive material that is not removed in the milling process. Potential radiation exposure can result from direct contact with the tailings, from radon gas emitted by the tailings, and from radioactive contamination of groundwater. As a result, the technology developed under the US Department of Energy (DOE) Uranium Mill Tailings Remedial Action Project (UMTRAP) and the US Nuclear Regulatory Commission (NRC) Uranium Recovery Program have focused on radon control, groundwater contamination and the long-term protection of the containment system. This paper briefly summarizes the UMTRAP and NRC remedial action technology development. 33 references, 9 figures, 5 tables

  8. Radon and remedial action in Spokane River Valley residences: an interim report

    International Nuclear Information System (INIS)

    Turk, B.H.; Prill, R.J.; Fisk, W.J.; Grimsrud, D.T.; Moed, B.A.; Sextro, R.G.

    1986-03-01

    Fifty-six percent of 46 residences monitored in the Spokane River Valley in eastern Washington/northern Idaho have indoor radon concentrations above the National Council for Radiation Protection (NCRP) guidelines of 8 pCi/1. Indoor levels were over 20 pCi/1 in eight homes, and ranged up to 132 pCi/1 in one house. Radon concentrations declined by factors of 4 to 38 during summer months. Measurements of soil emanation rates, domestic water supply concentrations, and building material flux rates indicate that diffusion of radon does not significantly contribute to the high concentrations observed. Rather, radon entry is dominated by pressure-driven bulk soil gas transport, aggravated by the local subsurface soil composition and structure. A variety of radon control strategies are being evaluated in 14 of these homes. Sub-surface ventilation by depressurization and overpressurization, basement overpressurization, and crawlspace ventilation are capable of successfully reducing radon levels below 5 pCi/1 in these homes. House ventilation is appropriate in buildings with low-moderate concentrations, while sealing of cracks has been relatively ineffective

  9. Radon in houses - identification of sources and pathways of transfer

    International Nuclear Information System (INIS)

    Robe, M.C.; Rannou, A.; Le Bronec, J.

    1992-01-01

    The Institut de Protection et de Surete Nucleaire (IPSN) is studying the remedial actions to reduce high concentration of radon in houses. The first step to know how to modify houses is to identify radon sources and pathways of transfer to upper floors. A pilot study in Brittany was designed to develop a simple method of diagnosis. This investigation was based on indoor and outdoor measurements of 222 Rn activity concentration in the air and 222 Rn area exhalation rate from the soils and walls, measurements of the potential alpha energy concentration of 222 Rn daughters and the ventilation rate. The structural characteristics of houses and the influence of the life style of the inhabitants were examined. Analysis of the results showed that a limited number of parameters can be selected for use in a rapid radon diagnosis. (author)

  10. A study of radon indoor concentration

    International Nuclear Information System (INIS)

    Pena, P.; Ruiz, W.; Segovia, N.; Ponciano, G.

    2000-01-01

    It was realized a study of radon concentration in houses of Mexico City and in a laboratory of the Nuclear Centre of Salazar, State of Mexico. The radon determination in air was realized with solid nuclear track detectors and with Honeywell and Alpha guard automatic equipment. The results show that the majority of houses have values under 148 Bq/m 3 obtaining some housings with upper values located in the Lomas zone. A study in smokers houses and another of controls showed very similar distributions. It was studied the day time fluctuations finding that radon increases considerably during the dawn. Some upper values obtained in a laboratory of the Nuclear Centre were remedied with ventilation. (Author)

  11. Method of reducing radon levels in buildings

    International Nuclear Information System (INIS)

    Khajdarov, R.A.; Gapurova, O.U.; Khajdarov, R.R.

    2004-01-01

    Radon concentration can be reduced by using polymeric compositions which fill pores inside building materials and decrease the coefficient of permeation of radon atoms and water molecules in building materials (concrete, gypsum, etc.). Polymeric silico-organic compounds were investigated and selected as the chemicals to prevent radon seeping indoors. Gas (air, Ar, 222 Rn, H 2 O) permeability of concrete and gypsum after treatment with chemicals was examined. The effect of the cement and sand types, preliminary treatment with various chemicals, type of the polymeric silico-organic compounds, time between treatments, moisture of concrete, time between the preparation of chemicals and the treatment of concrete (ageing of chemicals), time between the treatment of concrete and testing (ageing of treated concrete) were examined. Surfaces of the samples were treated by spraying. The experiments gave evidence that the chosen method of treatment of the construction materials allows reducing the coefficient of gas permeability in 200 - 400 times. Treatment of the floor, walls and ceiling of the basement of 5 buildings reduced the radon concentration in the premises of the first floor from 400-600 Bq/m 3 to the background value of 17-20 Bq/m 3

  12. Environmental Radon Gas and Degenerative Conditions An Overview

    Energy Technology Data Exchange (ETDEWEB)

    Groves-Kirkby, C.J. [Medical Physics Department, Northampton General Hospital, Northampton NN1 5BD (United Kingdom)]|[School of Health, University of Northampton, Northampton NN2 7AL (United Kingdom); Denman, A.R. [Medical Physics Department, Northampton General Hospital, Northampton NN1 5BD (United Kingdom); Woolridge, A.C. [School of Health, University of Northampton, Northampton NN2 7AL (United Kingdom)]|[School of Applied Sciences, University of Northampton, Northampton NN2 7AL (United Kingdom); Phillips, P.S. [School of Applied Sciences, University of Northampton, Northampton NN2 7AL (United Kingdom); Phillips, C. [School of Health, University of Northampton, Northampton NN2 7AL (United Kingdom)

    2006-07-01

    Radon, a naturally occurring radioactive gas, has variable distribution in the environment as a decay product of uranium occurring in a wide range of rocks, soils and building materials. Although radon dissipates rapidly in outdoor air, it concentrates in the built environment, and inhalation of {sup 222}Rn and its progeny {sup 218}Po and {sup 214}Po is believed to provide the majority of the radioactive dose to the respiratory system. While the connection between radon and lung cancer has long been recognised and investigated, recent studies have highlighted potential links between radon and other conditions, among them Multiple Sclerosis, Alzheimer and Parkinson Diseases, and Paget Disease of Bone. A strong case exists for clarifying the relationship between radon and these other conditions, not least since radon remediation to reduce lung cancer may conceivably have additional benefits hitherto unrecognized. The present status of the postulated links between environmental radon gas and degenerative conditions is reviewed, and recommendations for further research into levering current anti-radon campaigns are made. (authors)

  13. Safety at work: radon in the workplace

    International Nuclear Information System (INIS)

    Rimington, J.D.

    1992-01-01

    Under the Health and Safety at Work etc. Act, employers have a duty, so far as reasonably practicable, to maintain a safe working environment. To ensure that this occurs, the Health and Safety Commission defines standards and applies stimuli to make sure the standards are observed. The risk from radon ranks as one of the most severe industrial risks to be encountered in a hazardous industry. The Ionising Radiations Regulations specify a radon concentration above which the regulations apply, and various duties fall on the employer. Where an inspector finds radon concentrations above this level, he has the power to require remedial measures to be undertaken. (Author)

  14. Current status of programmes to measure and reduce radon exposure in Irish workplaces

    International Nuclear Information System (INIS)

    Colgan, P A; Madden, J S; Synnott, H; Fennell, S; Pollard, D; Fenton, D

    2004-01-01

    National legislation, which implements European Council Directive 96/29/EURATOM in Ireland, sets a reference level of 400 Bq m -3 averaged over any 3 month period for radon exposure in the workplace and also empowers the Radiological Protection Institute of Ireland to direct employers to have radon measurements carried out. This legislation came into effect in May 2000. Radon measurements have already been completed in show caves and other underground workplaces. Between 1998 and 2001, over 33 800 individual radon measurements were carried out in all ground floor offices and classrooms in 3444 schools nationwide as part of a programme undertaken jointly with the Department of Education and Science. Where the average indoor radon concentration in one or more rooms exceeded 200 Bq m -3 , remedial measures were implemented. For concentrations up to 400 Bq m -3 this involved increased ventilation while for higher concentrations an active sump was normally installed. The results of the survey, as well as the effectiveness of the different remedial strategies, are discussed. In the case of other above ground workplaces, different approaches have been adopted. As a first step, workplaces in two known high radon areas were directed to have radon measurements carried out. This programme had limited success because of problems in obtaining accurate workplace databases and a general lack of awareness on the part of employers of the issues involved. From a sample of 2610 employers directed to measure radon, only 408 actually completed measurements and 37 workplaces were identified as having average 3 month average radon concentrations above 400 Bq m -3 . A total of 1356 employers ignored all correspondence, some of which was sent by registered post and signed for on receipt. Current initiatives are focused on the provision of information and include newspaper advertising as well as publications aimed specifically at both employer and employee representative groups. The ability

  15. Current status of programmes to measure and reduce radon exposure in Irish workplaces

    Energy Technology Data Exchange (ETDEWEB)

    Colgan, P A; Madden, J S; Synnott, H; Fennell, S; Pollard, D; Fenton, D [Radiological Protection Institute of Ireland, 3 Clonskeagh Square, Dublin 14(Ireland)

    2004-06-01

    National legislation, which implements European Council Directive 96/29/EURATOM in Ireland, sets a reference level of 400 Bq m{sup -3} averaged over any 3 month period for radon exposure in the workplace and also empowers the Radiological Protection Institute of Ireland to direct employers to have radon measurements carried out. This legislation came into effect in May 2000. Radon measurements have already been completed in show caves and other underground workplaces. Between 1998 and 2001, over 33 800 individual radon measurements were carried out in all ground floor offices and classrooms in 3444 schools nationwide as part of a programme undertaken jointly with the Department of Education and Science. Where the average indoor radon concentration in one or more rooms exceeded 200 Bq m{sup -3}, remedial measures were implemented. For concentrations up to 400 Bq m{sup -3} this involved increased ventilation while for higher concentrations an active sump was normally installed. The results of the survey, as well as the effectiveness of the different remedial strategies, are discussed. In the case of other above ground workplaces, different approaches have been adopted. As a first step, workplaces in two known high radon areas were directed to have radon measurements carried out. This programme had limited success because of problems in obtaining accurate workplace databases and a general lack of awareness on the part of employers of the issues involved. From a sample of 2610 employers directed to measure radon, only 408 actually completed measurements and 37 workplaces were identified as having average 3 month average radon concentrations above 400 Bq m{sup -3}. A total of 1356 employers ignored all correspondence, some of which was sent by registered post and signed for on receipt. Current initiatives are focused on the provision of information and include newspaper advertising as well as publications aimed specifically at both employer and employee representative

  16. Radon mitigation in private dwellings. Summary of measures under the National Action Plan against Cancer in Norway 1999-2003

    International Nuclear Information System (INIS)

    Aanestad, K.; Strand, T.; Hoegmo, T.; Skjennem, M.; Jensen, C. L.; Hoelsbrekken, S.

    2006-01-01

    The report summarizes the remedial measurements carried out under the National Action Plan against Cancer in Norway in the period 1999-2003.The cost effectiveness of the state subsidized remedial measures against radon is evaluated. Other measurements under the National Action Plan against Cancer have also been evaluated, such as measurements of radon in 38.000 dwellings in 158 municipalities, information measures, and actions to increase radon mitigation competence in the building construction industry and in the municipalities. (Author)

  17. Methods of investigation and analysis on groundwater using radon as an indicator

    International Nuclear Information System (INIS)

    Hamada, Hiromasa; Imaizumi, Masayuki; Komae, Takami

    1997-01-01

    As for groundwater, the quality is good, and the temperature is constant throughout year, further, it can be easily utilized only by digging wells. The quantity of its utilization in one year is about 20% of total water utilization, and about 17 billion m 3 . Recently in Japan, the frequency of occurrence of water shortage is high, and the supply of river water is unstable, therefore, the importance of groundwater increased. It is indispensable to grasp in detail the state of groundwater flow as groundwater pollution is actualized, and the water quality has become problem. As the principle that radon becomes the index for groundwater analysis, the physical characteristic of radon and the features of the radon in groundwater are explained. The method of measuring radon concentration in groundwater and surface water is described. The investigation and analysis methods, to which the processes of radon formation and radon decay are applied, in which the equilibrium radon concentration in groundwater is used as the index, to which the relation of the degree of saturation in aquifer to the radon concentration in liquid phase is applied, and to which the difference of the concentrations in surface water and groundwater is applied, are reported. (K.I.)

  18. Radon and buildings: Pt. 1

    International Nuclear Information System (INIS)

    1994-02-01

    An effective way of reducing the level of radon in dwellings is to extract air from beneath the ground floor. This is usually achieved by mechanical ventilation or by use of a radon sump. However, in some circumstances, these remedial measures may lower the air pressure inside the dwelling. In a small number of cases, this causes combustion gases from open-flued combustion appliances, such as open fires, to spill into the living spaces. Spillage of this type is potentially hazardous. This leaflet recommends ways to reduce the likelihood of spillage, and suggests solutions if spillage does occur. (author)

  19. Nuclear tracks in solids and gas radon measurements

    International Nuclear Information System (INIS)

    Espinosa, G.

    2007-01-01

    Full text: The Department of Energy (DOE), the Environmental Protection Agency (EPA) in USA, and the European Community, have dedicated significant budget to the Radon study, its health effects and remedial actions for controlling and achieving lower levels, in these cases, nationwide research programs have been organized. With the aim to contribute on the radon levels knowledge in our country, the Applied Dosimetry Project at the Physics Institute of the University of Mexico has developed an indoor and outdoor radon measurement methodology. In this paper a passive radon detector device based on CR-39 polycarbonate for use in radon research and routine measurements is presented. As well the methodology for the track formation, automatic reading system, calibration procedure and measurements in a different location, are shown in this work. The results had been compared with dynamic detection systems, and another methodologies and research groups in order to have a high confidence in the radon levels reported. (Author)

  20. The National Radon Archive as a useful tool for developing and updating the National Radon Action Plan

    International Nuclear Information System (INIS)

    Bochicchio, F.; Antignani, S.; Carpentieri, C.; Ampollini, M.; Caccia, B.; Pozzi, S.; Venoso, G.

    2017-01-01

    International recommendations and regulations require developing of National Radon Action Plans (NRAPs) to effectively manage the protection of workers and population from radon exposure. In Italy, a NRAP was published in 2002 and several activities have been carried out in this framework. Information and data regarding these and previous activities have been collected in a National Radon Archive (NRA). Activities carried out by institutionally involved institutes and agencies include several national and regional surveys, involving more than 50 000 indoor environments (dwellings, schools and workplaces), and remedial actions performed in ∼350 buildings, largely in schools. Data collected in the NRA allowed also to estimate that lung cancer deaths attributable to radon exposure in Italy are ∼3400 per year. On-going developments of the Italian NRA finalized to effectively use it as tool for developing, monitoring and updating the NRAP are also described. (authors)

  1. Open charcoal chamber method for mass measurements of radon exhalation rate from soil surface

    International Nuclear Information System (INIS)

    Tsapalov, Andrey; Kovler, Konstantin; Miklyaev, Peter

    2016-01-01

    Radon exhalation rate from the soil surface can serve as an important criterion in the evaluation of radon hazard of the land. Recently published international standard ISO 11665-7 (2012) is based on the accumulation of radon gas in a closed container. At the same time since 1998 in Russia, as a part of engineering and environmental studies for the construction, radon flux measurements are made using an open charcoal chamber for a sampling duration of 3–5 h. This method has a well-defined metrological justification and was tested in both favorable and unfavorable conditions. The article describes the characteristics of the method, as well as the means of sampling and measurement of the activity of radon absorbed. The results of the metrological study suggest that regardless of the sampling conditions (weather, the mechanism and rate of radon transport in the soil, soil properties and conditions), uncertainty of method does not exceed 20%, while the combined standard uncertainty of radon exhalation rate measured from the soil surface does not exceed 30%. The results of the daily measurements of radon exhalation rate from the soil surface at the experimental site during one year are reported. - Highlights: • Radon exhalation rate from the soil surface area of 32 cm"2 can be measured at level of 10 mBq/(m"2s) at the uncertainty ≤30%. • The method has a metrological justification. • No need to consider climate conditions, soil properties and conditions, mechanism and rate of radon transport in the soil.

  2. Method for radon measurement in the subsoil in geothermal prospectus; Metodos de medicion de radon en el subsuelo en prospeccion geotermica

    Energy Technology Data Exchange (ETDEWEB)

    Balcazar G, M

    1991-02-15

    The present formless describe the technique for radon measurement in the underground, being able to be used as an additional study in the geothermal prospecting. This methodology has been developed in the National Institute of Nuclear Research of Mexico using a film of cellulose nitrate to detect those emanated alpha particles, by the Rn (222). By means of the trace account in this films its settle down the present radon levels in the underground. The present method thinks about as an alternating one to overcome in it leaves the limitations found in the development of the methodology using a radon emanometer ETR-1, of the trade mark SCINTREX. The radon detected by plastics is also an integral method of measuring in a geothermal field that avoids the problems of variations of radon to pluvial precipitations and barometric variations. These variations affect the results strongly when it is used the punctual sampler as it is the ETR-1. (Author)

  3. Proceedings of the 4th European conference on protection against radon at home and at work. Conference programme and session presentations

    International Nuclear Information System (INIS)

    2004-01-01

    The conference was divided into 6 sections as follows (the numbers of PDF files included in the CD-ROM are given in parentheses): 1. Radon measurement in dwellings (7); 2. Radon measurement at workplaces (14); 3. Methods of measurement and devices (16); 4. Remedial measures and techniques (5); 5. Preventive measures and techniques (10); and 6. National radon programmes (6). In addition, the CD-ROM contains 3, 11, 9, 5, 6, and 6 PowerPoint presentations shown in the six sections, respectively, plus a total of 93 abstracts, mostly of posters. (P.A.)

  4. Control of indoor radon and radon progeny concentrations

    International Nuclear Information System (INIS)

    Sextro, R.G.

    1985-05-01

    There are three general categories of techniques for the control of radon and radon progeny concentrations in indoor air - restriction of radon entry, reduction of indoor radon concentrations by ventilation or air cleaning, and removal of airborne radon progeny. The predominant radon entry process in most residences appears to be pressure driven flow of soil gas through cracks or other openings in the basement, slab, or subfloor. Sealing these openings or ventilation of the subslab or subfloor space are methods of reducing radon entry rates. Indoor radon concentrations may be reduced by increased ventilation. The use of charcoal filters for removal of radon gas in the indoor air by adsorption has also been proposed. Concentrations of radon progeny, which are responsible for most of the health risks associated with radon exposures, can be controlled by use of electrostatic or mechanical filtration. Air circulation can also reduce radon progeny concentrations in certain cases. This paper reviews the application and limitations of each of these control measures and discusses recent experimental results

  5. Continuous measurement of the radon concentration in water using electret ion chamber method

    International Nuclear Information System (INIS)

    Dua, S.K.; Hopke, P.K.

    1992-10-01

    A radon concentration of 300 pCi/L has been proposed by the US Environmental Protection Agency as a limit for radon dissolved in municipal drinking water supplies. There is therefore a need for a continuous monitor to insure that the daily average concentration does not exceed this limit. In order to calibrate the system, varying concentrations of radon in water have been generated by bubbling radon laden air through a dynamic flowthrough water system. The value of steady state concentration of radon in water from this system depends on the concentration of radon in air, the air bubbling rate, and the water flow rate. The measurement system has been designed and tested using a 1 L volume electret ion chamber to determine the radon in water. In this dynamic method, water flows directly through the electret ion chamber. Radon is released to the air and measured with the electret. A flow of air is maintained through the chamber to prevent the build-up of high radon concentrations and too rapid discharge of the electret. It was found that the system worked well when the air flow was induced by the application of suction. The concentration in the water was calculated from the measured concentration in air and water and air flow rates. Preliminary results suggest that the method has sufficient sensitivity to measure concentrations of radon in water with acceptable accuracy and precision

  6. Efficiency of radon reduction techniques and strategies

    International Nuclear Information System (INIS)

    Hubert, Ph.; Monchecourt, D.

    2000-01-01

    Radon is a lung carcinogen recognized by the World Health Organisation and it is present in dwellings. In France, the first actions to measure the exposition of the population were made in 1982, and the first national recommendation was published in 1999. In parallel, information booklets on radon and possible actions to lower its concentration in house were made available to the public. The aim of this study was to test the economic feasibility of different methods to reduce radon level in housing. The first step was to identify the cost and the radon reduction rate of different methods, all based on insulation or ventilation of the buildings. Using the data of the Environmental Protection Agency (EPA), we selected six measures and combined them to obtain a total of twenty potential solutions. We also used the 'duration' model of the Biological Effects of Ionising Radiation committee (BEIR VI) to determine the probability of dying from a cancer associated to a fixed exposure to radon. Knowing this information, it was possible to make cost-efficiency analysis on our data and thus keep six interesting methods. Combining these results with the value of human life of the human capital approach we could find what was the most interesting method to apply for a known level of radon and a specific duration of exposure in a house. In given house, for each level of initial exposure, a cost benefit approach allowed to determine if one, or several techniques, or none, is worthwhile to apply. In favorable cases (i.e : easily remediable houses), and with a figure for the price of human life of about 0,9 MEuro, actions should be undertaken at levels as low as 80 Bq.m -3 . As we know the radon distribution in France, the second step was to see what would be the effects on this distribution if all inhabitants used the optimal approach against their radon exposure defined by our function. Thus, overall costs and overall risks could be computed. However, in public health issues, the

  7. Preliminary research on finite difference method to solve radon field distribution over sandstone-type uranium ore body

    International Nuclear Information System (INIS)

    Li Bihong; Shuang Na; Liu Qingcheng

    2006-01-01

    The principle of finite difference method is introduced, and the radon field distribution over sandstone-type uranium deposit is narrated. The radon field distribution theory equation is established. To solve radon field distribution equation using finite difference algorithm is to provide the value computational method for forward calculation about radon field over sandstone-type uranium mine. Study on 2-D finite difference method on the center of either high anomaly radon fields in view of the character of radon field over sandstone-type uranium provide an algorithm for further research. (authors)

  8. Radon in Austria

    International Nuclear Information System (INIS)

    Friedmann, H.

    2000-01-01

    Several projects in Austria deal with the problem of enhanced radon exposure to the public. The Austrian Radon Project is the largest project within this task, with the aim of investigating the radon concentrations in Austrian homes. Another project concerns mitigation methods. According to the EU directive EURATOM 96/29 it is also necessary to check working places for possibly enhanced radon concentrations. These projects are and will be funded by the government. The federal government of Upper Austria sponsored a project to test the indoor air quality in kindergartens including radon measurements. Within an EU research project, the radon concentrations in Austrian springs and groundwater were systematically listed and analyzed. Additional investigations will focus on methods to improve the radon potential maps from the Austrian Radon Project by including geological and other information. (author)

  9. Comparison of active and passive methods for radon exhalation from a high-exposure building material

    International Nuclear Information System (INIS)

    Abbasi, A.; Mirekhtiary, F.

    2013-01-01

    The radon exhalation rates and radon concentrations in granite stones used in Iran were measured by means of a high-resolution high purity Germanium gamma-spectroscopy system (passive method) and an AlphaGUARD model PQ 2000 (active method). For standard rooms (4.0 x 35.0 m area x 32.8 height) where ground and walls have been covered by granite stones, the radon concentration and the radon exhalation rate by two methods were calculated. The activity concentrations of 226 Ra in the selected granite samples ranged from 3.8 to 94.2 Bq kg -1 . The radon exhalation rate from the calculation of the 226 Ra activity concentration was obtained. The radon exhalation rates were 1.31-7.86 Bq m -2 h -1 . The direction measurements using an AlphaGUARD were from 218 to 1306 Bq m -3 with a mean of 625 Bq m -3 . Also, the exhalation rates measured by the passive and active methods were compared and the results of this study were the same, with the active method being 22% higher than the passive method. (authors)

  10. Project Radon

    International Nuclear Information System (INIS)

    Ekholm, S.

    1988-01-01

    The project started in March 1987. The objective is to perform radon monitoring in 2000 dwellings occupied by people employed by State Power Board and to continue to contribute to the development of radon filters. The project participates in developing methods for radon measurement and decontamination and in adapting the methods to large scale application. About 400 so called radon trace measurements (coarse measurement) and about 10 action measurements (decontamination measurement) have been made so far. Experience shows that methods are fully applicable and that the decontamination measures recommended give perfectly satisfactory results. It is also established that most of the houses with high radon levels have poor ventilation Many of them suffer from moisture and mould problems. The work planned for 1988 and 1989 will in addition to measurements be directed towards improvement of the measuring methods. An activity catalogue will be prepared in cooperation with ventilation enterprises. (O.S.)

  11. The unintentional and unconscious exposure to radon (and other natural radionuclides)

    International Nuclear Information System (INIS)

    Thomas, J.

    1998-01-01

    The radon programmes for dwellings (remediation of the risk and prevention of the risk) as well as radon programmes for workplaces in the Czech Republic are described. To implementation radiation protection against natural radiation sources on workplaces with unintentional and unconscious exposure to these sources of radiation is a new, but interesting and important task which need new approaches, time staff and effort

  12. Preventing excessive radon exposure in U.K. housing

    International Nuclear Information System (INIS)

    Miles, J.C.H.; Cliff, K.D.; Green, B.M.R.; Dixon, D.W.

    1992-01-01

    In the United Kingdom (UK) it has been recognized for some years that some members of the population received excessive radiation exposure in their homes from radon and its decay products. To prevent such exposures, an Action Level of 400 Bq m -3 was adopted in 1987. In January, 1990, the National Radiological Protection Board (NRPB) advised that the Action Level should be reduced to 200 Bq m -3 , and this advice was accepted by the Government. It is estimated that exposures in up to 100,000 UK homes exceed this Action Level; this amounts to about 0.5% of the available housing. The UK authorities have developed a strategy for preventing such exposures: (1) Areas in which it is estimated that >1% of homes exceed the Action Level for radon are being designated as Affected Areas, and a program to map such areas is under way. Households in these areas are advised to have radon measurements made by NRPB under a open-quotes freeclose quotes (Government-funded) scheme. (2) Householders found to have whole-house, whole-year average radon concentrations >200 Bq m -3 are advised to take remedial action and are provided with information on how this can be done. Partial grants toward remedial work are available in cases of financial need. So far, around 3000 such households have been identified. (3) Within Affected Areas, localities are being defined where new homes must incorporate precautions against radon exposure. In addition to this strategy, a joint case-control study of the risks of radon in homes is being undertaken by the Imperial Cancer Research Fund and NRPB, supported by the UK Government and the Commission of the European Communities

  13. Report on investigation of remedial measures for the radiation reduction and radioactive decontamination of Elliot Lake, Ontario

    International Nuclear Information System (INIS)

    1981-02-01

    This is the fourth annual report on a program to monitor and reduce radon daughter exposures in the town of Elliot Lake, Ontario. Twelve month's WL survey measurements were completed in 1980 and showed that 22 houses exceeded the remedial action criterion of 0.02 WL. In a few cases gamma radiation levels were high enough to require remedial action in driveways and public areas, but not inside houses. During 1980 remedial work was carried out on 85 buildings; work was completed on 58. The most frequent routes of entry for radon and radon daughters were untrapped weeping tile connected to a floor drain or sump, and the wall to floor joint

  14. A universal laboratory method for determining physical parameters of radon migration in dry granulated porous media.

    Science.gov (United States)

    Ye, Yong-Jun; Zhang, Yun-Feng; Dai, Xin-Tao; Ding, De-Xin

    2017-10-01

    The particle size and heaped methods of exhalation media have important effects on physical parameters, such as the free radon production rate, porosity, permeability, and radon diffusion coefficient. However, existing methods for determining those parameters are too complex, and time-consuming. In this study, a novel, systematic determining method was proposed based on nuclide decay, radon diffusion migration theory, and the mass conservation law, and an associated experimental device was designed and manufactured. The parameters of uranium ore heap and sandy soil of radon diffusion coefficient (D), free radon production rate (α), media permeability (k), and porosity (ε) were obtained. At the same time, the practicality of the novel determining method was improved over other methods, with the results showing that accuracy was within the acceptable range of experimental error. This novel method will be of significance for the study of radon migration and exhalation in granulated porous media. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Inter-comparison of different direct and indirect methods to determine radon flux from soil

    International Nuclear Information System (INIS)

    Grossi, C.; Vargas, A.; Camacho, A.; Lopez-Coto, I.; Bolivar, J.P.; Xia Yu; Conen, F.

    2011-01-01

    The physical and chemical characteristics of radon gas make it a good tracer for use in the application of atmospheric transport models. For this purpose the radon source needs to be known on a global scale and this is difficult to achieve by only direct experimental methods. However, indirect methods can provide radon flux maps on larger scales, but their reliability has to be carefully checked. It is the aim of this work to compare radon flux values obtained by direct and indirect methods in a measurement campaign performed in the summer of 2008. Different systems to directly measure radon flux from the soil surface and to measure the related parameters terrestrial γ dose and 226 Ra activity in soil, for indirect estimation of radon flux, were tested. Four eastern Spanish sites with different geological and soil characteristics were selected: Teruel, Los Pedrones, Quintanar de la Orden and Madrid. The study shows the usefulness of both direct and indirect methods for obtaining radon flux data. Direct radon flux measurements by continuous and integrated monitors showed a coefficient of variation between 10% and 23%. At the same time, indirect methods based on correlations between 222 Rn and terrestrial γ dose rate, or 226 Ra activity in soil, provided results similar to the direct measurements, when these proxies were directly measured at the site. Larger discrepancies were found when proxy values were extracted from existing data bases. The participating members involved in the campaign study were the Institute of Energy Technology (INTE) of the Technical University of Catalonia (UPC), Huelva University (UHU), and Basel University (BASEL).

  16. Dealing with radon in dwellings

    International Nuclear Information System (INIS)

    Castren, O.

    1987-01-01

    A review is made of the measurements, regulatory initiatives and remedial action taken in Finland since the discovery in 1981 of the first indoor radon concentrations higher than 10,000 Bq/m 3 . The emphasis is on the results of measurements, explanations of them and their use for the rational solution of the radon problems. Localizing the high-concentration areas and dwellings has been one of the main objectives. The latest radon map is based on measurements in 8,150 dwellings in 235 localities. The geographical distribution cannot be explained only by the uranium concentration of the bedrock. The main reason for deviations is the ground permeability. The local fine structure is most notably influenced by the glacifluvial sand and grvel formations (eskers and ice-marginal formations). The highest concentrations are often caused by synergism between an elevated uranium concentration, situation on an esker and a great temperature difference between indoor and outdoor air. They are usually connected with a large seasonal variation, the concentration being at maximum during the coldest time in winter. Indoor radon distribution is compared with newly published maps on the incidence of lung cancer in Finland

  17. Let us take action against radon

    International Nuclear Information System (INIS)

    Vignaud, Pierre; Mercat, Francois

    2015-01-01

    The Limousin region, because of its geological characteristics, is one of the most concerned by the presence of radon. A first article evokes actions undertaken in two local communities of this region to detect radon presence in dwellings with notably a free distribution of thousand measurement kits. A second article presents this radioactive gas, explains why it is such a matter of concern, and what risks for health are. The third article describes how the measurement kit is used to perform a complete diagnosis: it comprises three dose measurement devices, an information document, and a questionnaire. The presidents of the both involved local communities explain their commitment. A map indicates places where people can get the measurement kits. The next article presents what will be done after the measurement programme. An article briefly evokes the radon issue and actions undertaken in Canada. In an interview two experts indicate how they will support inhabitants in their remediation actions. An article briefly describes what to do in case of a strong presence of radon in a house

  18. The effect of desiccation on UMTRA Project radon barrier materials

    International Nuclear Information System (INIS)

    1990-11-01

    The proposed US Environmental Protection Agency (EPA) groundwater standards (40 CFR 192) require that Uranium Mill Tailings Remedial Action (UMTRA) Project remedial action designs meet low numerical limits for contaminants contained in water or vapors exiting the disposal cell embankments. To meet the standards, a cover of compacted, fine-grained soil is placed over UMTRA Project embankments. One of the functions of this cover is to limit infiltration into the disposal cell . The hydraulic conductivity of this infiltration barrier must be low in order to reduce the resultant seepage from the base of the cell to the extent necessary to comply with the proposed EPA groundwater standards. Another function of this cover is to limit the emission of radon gas. The air permeability of the cover must be low in order to reduce radon emissions to comply with EPA standards. Fine-grained soils exposed to evaporation will dry. Continued exposure will cause shrinking that, if allowed to continue, will eventually result in the development of cracks. The results of the cracking could be an increase in the hydraulic conductivity and an increase in the air permeability. This could then allow additional infiltration and increased radon emissions. Cracking of the radon barrier has been noted at one UMTRA Project location. The potential for cracking of the radon barrier during construction has been addressed by requiring moistening of previously compacted surfaces prior to placing additional lifts. The efficacy of these treatments has not been verified. The potential for cracking after construction of the cover is completed has also not been examined. The purpose of this study is to evaluate the potential for cracking of the radon barrier both during construction and after completion of the cover. The effect of shrinkage cracking on the performance of the radon barrier will also be examined

  19. Radon and radon progeny in 70 houses in the Tennessee Valley area: study design and measurement methods

    International Nuclear Information System (INIS)

    Dudney, C.S.; Hawthorne, A.R.; Monar, K.P.; Quillen, J.L.; Clark, C. Jr.; Doane, R.W.; Wallace, R.G.; Reed, R.P.

    1986-01-01

    Levels of radon and its short-lived airborne progeny are being measured in a year-long study of 70 houses in four states in the Tennessee Valley. Various methods were used to solicit volunteers with differing degrees of success. Criteria for selection of houses in the study included presence of a lower level with cement floor and one or more block walls in contact with the soil, absence of obvious indications of technologically enhanced sources of radium, and proximity to one of four cities, (Knoxville, Chattanooga, Birmingham, or Florence). By design, most houses in the study are in the same neighborhood as at least one other house in the study. Houses range in age from newly constructed to about 40 years old. Most of the houses have more than 2000 square feet of finished floor space. The lower level encompasses a garage in most cases. More complete information pertaining to house characteristics will be gathered in the course of the study. Measurements are being made to obtain information on both location- and season-dependent variation of radon and radon progeny. Simultaneous measurements are made quarterly on both upper and lower levels of each house. Grab samples of air are collected and analyzed for radon using a modified Lucas cell technique. Short-term (10-minute) samples of airborne particulate material are collected and analyzed for radon progeny. One-week integrated measurements of working levels are made once each quarter using modified thermoluminescent dosimeters. Both three- and twelve-month integrated measurements of radon using track-etch monitors are being made. 19 references, 1 figures

  20. Radon testing in schools in New York State: a 20-year summary

    International Nuclear Information System (INIS)

    Kitto, Michael

    2014-01-01

    For nearly 20 years the Department of Health has conducted programs to assist in the measurement and reduction of indoor radon concentrations in 186 schools located primarily in Zone 1 areas of New York State. Although many schools had few or no rooms containing radon above 148 Bq/m 3 , some rooms had >740 Bq/m 3 and remediation techniques were utilized to reduce exposure. Short-term radon measurements in the schools showed little correlation to basement and first-floor radon results from single-family homes in the towns. - Highlights: • Relatively few schools in New York State have been tested for indoor radon. • We provide a summary of radon-testing results for measured schools. • The radon potential in schools is often less than in local houses. • Short-term measurement results exceeded their long-term counterparts in nearly every case

  1. Radon reduction in waterworks

    International Nuclear Information System (INIS)

    Raff, O.; Haberer, K.; Wilken, R.D.; Funk, H.; Stueber, J.; Wanitschek, J.; Akkermann-Kubillus, A.; Stauder, S.

    2000-01-01

    The removal of radon from water using water aeration is one of the most effective methods for reducing radon in waterworks. Therefore, this report describes investigations on packed tower columns and shallow aeration devices and a method for mathematical modelling of gas exchange processes for dimensioning packed tower columns for radon removal. Moreover, possibilities for removing radon using active carbon filtration under waterworks typical conditions and for reducing indoor radon levels in waterworks are discussed. Finally, conclusions on the necessity of radon removal in German waterworks are drawn. (orig.) [de

  2. Risk assessment in the DOE Assurance Program for Remedial Action

    International Nuclear Information System (INIS)

    Marks, S.; Cross, F.T.; Denham, D.H.; Kennedy, W.E.; Stenner, R.D.

    1985-08-01

    This document provides information obtained during the performance of risk assessment tasks in support of the Assurance Program for Remedial Action (APRA) sponsored by the Office of Operational Safety of the Department of Energy. We have presented a method for the estimation of projected health effects at properties in the vicinity of uranium mill tailing piles due to transported tailings or emissions from the piles. Because radon and radon daughter exposure is identified as the principal factor contributing to health effects at such properties, the basis for estimating lung cancer risk as a result of such exposure is discussed in detail. Modeling of health risk due to a secondary pathway, ingestion of contaminated, home-grown food products, is also discussed since it is a potentially important additional source of exposure in certain geographic locations. Risk assessment methods used in various mill tailings reports are reviewed. The protocols for radiological surveys conducted in DOE-sponsored remedial action programs are critically reviewed with respect to their relevance to the needs of health risk estimation. The relevance of risk assessment to the APRA program is discussed briefly

  3. Radon and radon daughter monitoring (including thoron daughter monitoring)

    International Nuclear Information System (INIS)

    Leach, V.A.; Grealy, G.; Gan, W.

    1982-01-01

    Radon/radon daughter and thoron daughter measurement techniques are outlined. The necessary precautions and critical assessments of each method are also presented with a view to providing a better understanding of the various measurement methods

  4. Radon

    Energy Technology Data Exchange (ETDEWEB)

    Weigel, F [Muenchen Univ. (Germany, F.R.). Inst. fuer Anorganische Chemie

    1978-09-01

    The noble gas radon, formerly called emanation, was discovered a few years after radium. /sup 222/Rn, the longest-lived isotope, has a half-life of 3,82 days. This half life is so short that the experimental techniques available at present (1978) are not sufficient for a characterization of defined radon compounds, even though there are definite indications for the existence of such compounds, and one may expect such radon compounds to be even more stable than the numerous known xenon compounds. - The radon isotopes /sup 219/Rn (Actinon), /sup 220/Rn (Thoron), and /sup 222/Rn (Radon) occur in nature despite their rather short half-lives, because they are continously generated from their mothers /sup 223/Ra, /sup 224/Ra, and /sup 226/Ra, which are in secular equilibrium with long-lived isotopes /sup 235/U, /sup 238/U, and /sup 232/Th, and are in turn continously formed from these long-lived isotopes. Since the radon isotopes are gases, they enter the atmosphere and are carried for long distances with air currents. - Because radon is so short-lived, its practical applications are rather limited. For medical applications, small sealed glass tubes filled with radon are used as radiation sources after the radon has decayed, because the whole series of Po-, Bi-, and Pb-isotopes of the radium decay chain are formed, whose penetrating radiation is useful for therapy. When solids are spiked with Ra isotopes, radon is evolved at a constant rate. On heating such solids, phase transitions show up by sudden increased radon evolution (Hahn's emanation method). - On the basis of nuclear theoretical calculations, there is hardly a chance for the discovery of a long-lived radon species. Therefore, major progress in radon chemistry is hardly to be expected in the near future.

  5. Study of radon 222 permeation through plastic membranes. Application to a measurement method of radon in water

    International Nuclear Information System (INIS)

    Labed, V.; Rannou, A.; Robe, M.C.

    1990-01-01

    Gaseous permeation is a complex phenomenon of gas transfer through some polymers. Original in respect of conventional studies where permeation occurs between two gaseous phases, the present study concerns radon 222 transfer between water and air through a membrane. Polypropylene membranes are tested with an experimental device following time evolution of the phenomenon by measurement of volume activity in water and in air. An application of this study to a method for determination of radon concentration in water by measurement of concentration in air is discussed [fr

  6. Measurement of unattached radon progeny based in electrostatic deposition method

    International Nuclear Information System (INIS)

    Canoba, A.C.; Lopez, F.O.

    1999-01-01

    A method for the measurement of unattached radon progeny based on its electrostatic deposition onto wire screens, using only one pump, has been implemented and calibrated. The importance of being able of making use of this method is related with the special radiological significance that has the unattached fraction of the short-lived radon progeny. Because of this, the assessment of exposure could be directly related to dose with far greater accuracy than before. The advantages of this method are its simplicity, even with the tools needed for the sample collection, as well as the measurement instruments used. Also, the suitability of this method is enhanced by the fact that it can effectively be used with a simple measuring procedure such as the Kusnetz method. (author)

  7. Radon: the building industry view

    International Nuclear Information System (INIS)

    Farnham, K.G.R.

    1992-01-01

    Guidance on radon preventive measures in new dwellings is covered by the Building Regulations, and adequate guidance has been published by the Building Research Establishment. This is a satisfactory state of affairs which, unfortunately, is not the case for remedial work in existing buildings. Work in existing buildings should be incorporated in Regulations and adequate funding should be provided by government for the training of builders. (Author)

  8. Comparison of passive and active radon measurement methods for personal occupational dose assessment

    Directory of Open Access Journals (Sweden)

    Hasanzadeh Elham

    2016-01-01

    Full Text Available To compare the performance of the active short-term and passive long-term radon measurement methods, a study was carried out in several closed spaces, including a uranium mine in Iran. For the passive method, solid-state nuclear track detectors based on Lexan polycarbonate were utilized, for the active method, AlphaGUARD. The study focused on the correlation between the results obtained for estimating the average indoor radon concentrations and consequent personal occupational doses in various working places. The repeatability of each method was investigated, too. In addition, it was shown that the radon concentrations in different stations of the continually ventilated uranium mine were comparable to the ground floor laboratories or storage rooms (without continual ventilation and lower than underground laboratories.

  9. Radon-Instrumentation; Radon-Instrumentacion

    Energy Technology Data Exchange (ETDEWEB)

    Moreno y Moreno, A. [Departamento de Apoyo en Ciencias Aplicadas, Benemerita Universidad Autonoma de Puebla, 4 Sur 104, Centro Historico 72000 Puebla (Mexico)

    2003-07-01

    The presentation of the active and passive methods for radon, their identification and measure, instrumentation and characteristics are the objectives of this work. Active detectors: Active Alpha Cam Continuous Air Monitor, Model 758 of Victoreen, Model CMR-510 Continuous Radon Monitor of the Signature Femto-Tech. Passive detectors: SSNTD track detectors in solids Measurement Using Charcoal Canisters, disk of activated coal deposited in a metallic box Electrets Methodology. (Author)

  10. A study of radon levels in NHS premises in affected areas around the UK

    International Nuclear Information System (INIS)

    Denman, A.R.; Lewis, G.T.R.; Brennen, S.E.

    2002-01-01

    Radon gas contributes a significant fraction of the natural background radiation dose, and in some areas raised levels are found in buildings, both homes and the workplace. Different UK Action Levels apply to homes and the workplace, because of the diurnal variation of radon. This study reviews the results for a number of hospitals throughout England and Wales, and suggests that the likelihood of finding raised radon levels is similar in the workplace and homes in the same area. Radon measurements and consequent remediation of any raised levels are appropriate in all workplaces in radon Affected Areas with over 5% of houses above the UK domestic Action Level of 200 Bq m -3

  11. Spectral-ratio radon background correction method in airborne γ-ray spectrometry based on compton scattering deduction

    International Nuclear Information System (INIS)

    Gu Yi; Xiong Shengqing; Zhou Jianxin; Fan Zhengguo; Ge Liangquan

    2014-01-01

    γ-ray released by the radon daughter has severe impact on airborne γ-ray spectrometry. The spectral-ratio method is one of the best mathematical methods for radon background deduction in airborne γ-ray spectrometry. In this paper, an advanced spectral-ratio method was proposed which deducts Compton scattering ray by the fast Fourier transform rather than tripping ratios, the relationship between survey height and correction coefficient of the advanced spectral-ratio radon background correction method was studied, the advanced spectral-ratio radon background correction mathematic model was established, and the ground saturation model calibrating technology for correction coefficient was proposed. As for the advanced spectral-ratio radon background correction method, its applicability and correction efficiency are improved, and the application cost is saved. Furthermore, it can prevent the physical meaning lost and avoid the possible errors caused by matrix computation and mathematical fitting based on spectrum shape which is applied in traditional correction coefficient. (authors)

  12. An evaluation of the effectiveness of the UK programme to protect new buildings in radon affected areas

    International Nuclear Information System (INIS)

    Denman, A.R.; Fraser, J.; Phillips, P.S.

    2000-01-01

    The discovery of areas in the UK with significant indoor radon levels prompted the Building Research Establishment in 1992 to publish guidance (1) specifying protection measures, enforced by law, when building new houses in radon Affected Areas. In high risk areas, with over 10% of existing houses above the 200 Bq m -3 Action Level, primary protection in the form of a radon-proof membrane is required, as well as secondary protection in the form of a sump capable of being fitted with a low cost pump. In lower risk areas with 3 to 10% of houses above the Action Level only secondary protection is specified. This latter requirement reduces the cost of providing radon remediation to around pound 150 for the fan, rather than an average of pound 750 for providing a sump and fitting a fan, but requires measurement of the radon level to judge whether remediation is required. Northamptonshire, with 6.3% of houses above the Action Level, has areas of both high and lower risk. There has been considerable influx of population in recent years, with 12,200 new houses built since 1993. In high risk areas in Northamptonshire, the collective dose reduction of primary protection has been calculated and has now reached 23 man-sieverts per year has been avoided in the total of 7,900 houses built since 1993. Using current NRPB risk estimates this is equivalent to 0.8 lung cancers avoided each year. This is similar to that achieved by the remediation programme in existing housing, although the potential saving in existing housing is much greater if more householders can be encouraged to carry out remediation (2). In addition, two new housing estates in the lower risk area have been assessed by issuing 6-day etched track detectors to householders, and using a questionnaire to assess their knowledge of radon. Two detectors were used, one in the living area and bedroom, and results were combined using the NRPB protocol to give a weighted seasonally corrected average radon level. In one

  13. Toward a standard method for determination of waterborne radon

    International Nuclear Information System (INIS)

    Vitz, E.

    1990-01-01

    When the USEPA specifies the maximum contaminant level (MCL) for any contaminant, a standard method for analysis must be simultaneously stipulated. Promulgation of the proposed MCL and standard method for radon in drinking water is expected by early next year, but a six-month comment period and revision will precede final enactment. The standard method for radon in drinking water will probably specify that either the Lucas cell technique or liquid scintillation spectrometry be used. This paper reports results which support a standard method with the following features: samples should be collected by an explicitly stated technique to control degassing, in glass vials with or without scintillation cocktail, and possibly in duplicate; samples should be measured by liquid scintillation spectroscopy in a specified energy window', in a glass vial with particular types of cocktails; radium standards should be prepared with controlled quench levels and specified levels of carriers, but radium-free controls prepared by a specified method should be used in interlaboratory comparison studies

  14. Professional liability of the radon technologist

    International Nuclear Information System (INIS)

    Kornreich, M.R.

    1987-01-01

    The radon technologist will want to protect himself from lawsuits by plaintiffs who believe they have suffered consequences of a false measurement or erroneous recommendation. The author may be sued for negligence or on the contract. A plaintiff is more likely to be successful in a suit for monetary losses associated with real estate transactions or remediation than in a suit for personal injury. To avoid liability, the radon technologist will want to keep aware of the state of the art; use standard protocols; carefully supervise employees; take all technical precaution; and get legal advice in contracting. The author should also adhere to applicable federal, state, or local regulations. Disclosing the limits of measurement procedures and emphasizing the importance of maintaining standardized environmental conditions in the building are important. Since it is extremely difficult for an individual to get adequate professional liability insurance at a reasonable price, radon technologists should cooperate, perhaps through their professional societies, to negotiate the best possible insurance policies

  15. Effective diffusion coefficient of radon in concrete, theory and method for field measurements

    International Nuclear Information System (INIS)

    Culot, M.V.J.; Olson, H.G.; Schiager, K.J.

    1976-01-01

    A linear diffusion model serves as the basis for determination of an effective radon diffusion coefficient in concrete. The coefficient was needed to later allow quantitative prediction of radon accumulation within and behind concrete walls after application of an impervious radon barrier. A resolution of certain discrepancies noted in the literature in the use of an effective diffusion coefficient to model diffusion of a radioactive gas through a porous medium is suggested. An outline of factors expected to affect the concrete physical structure and the effective diffusion coefficient of radon through it is also presented. Finally, a field method for evaluating effective radon diffusion coefficients in concrete is proposed and results of measurements performed on a concrete foundation wall are compared with similar published values of gas diffusion coefficients in concrete. (author)

  16. Development of a model for radon concentration in indoor air

    International Nuclear Information System (INIS)

    Jelle, Bjørn Petter

    2012-01-01

    A model is developed for calculation of the radon concentration in indoor air. The model takes into account various important parameters, e.g. radon concentration in ground, radon diffusion resistance of radon barrier, air permeance of ground, air pressure difference between outdoor ground and indoor at ground level, ventilation of the building ground and number of air changes per hour due to ventilation. Characteristic case studies are depicted in selected 2D and 3D graphical plots for easy visualization and interpretation. The radon transport into buildings might be dominated by diffusion, pressure driven flow or a mixture of both depending on the actual values of the various parameters. The results of our work indicate that with realistic or typical values of the parameters, most of the transport of radon from the building ground to the indoor air is due to air leakage driven by pressure differences through the construction. By incorporation of various and realistic values in the radon model, valuable information about the miscellaneous parameters influencing the indoor radon level is gained. Hence, the presented radon model may be utilized as a simple yet versatile and powerful tool for examining which preventive or remedial measures should be carried out to achieve an indoor radon level below the reference level as set by the authorities. - Highlights: ► Model development for calculation of radon concentration in indoor air. ► Radon model accounting for various important parameters. ► Characteristic case studies depicted in 2D and 3D graphical plots. ► May be utilized for examining radon preventive measures.

  17. Map showing radon potential of rocks and soils in Montgomery County, Maryland

    Science.gov (United States)

    Gundersen, L.C.; Reimer, G.M.; Wiggs, C.R.; Rice, C.A.

    1988-01-01

    This report summarizes the radon potential of Montgomery County in the context of its geology. Radon is a naturally occurring gas produced by the radioactive decay of uranium. Radon produced by uraniferous rocks and soils may enter a house through porous building materials and through openings in walls and floors. Radon gases has a tendency to move from the higher pressure commonly existing in the soil to the lower pressure commonly existing in the house. The U.S. Environmental Protection Agency (U.S. EPA, 1986a) estimates that elevated levels of indoor radon may be associated with 5,000 to 20,000 of the 130,000 lung cancer deaths per year. They also estimate that 8 to 12 percent of the homes in the United States will have annual average indoor radon levels exceeding 4 picoCuries per liter of air (pCi/L). Above this level, the U.S. EPA recommends homeowners take remedial action. May factors control the amount of radon which may enter a home from the geologic environment. Soil drainage, permeability, and moisture content effect the amount of radon that can be released from rocks and soils (known as the emmanation) and may limit or increase how far it can migrate. Well drained, highly permeable soils facilitate the movement of radon. Soils with water content in the 8 to 15 percent range enhance the emmanation of radon (Lindmark, 1985). Daily and seasonal variations in soil and indoor radon can be caused by meteorologic factors such as barometric pressure, temperature, and wind (Clements and Wilkening, 1974; Schery and other, 1984). Construction practices also inhibit or promote entry of radon into the home (U.S. EPA, 1986b). In general, however, geology controls the source and distribution of radon (Akerblom and Wilson, 1982; Gundersen and others, 1987, 1988; Sextro and others, 1987; U.S. EPA, 1983; Peake, 1988; Peake and Hess, 1988). The following sections describe: 1) the methods used to measure radon and equivalent uranium (eU) in soil; 2) the radon potential

  18. Technique and equipment for measuring volume activity of radon in the air of radon laboratories and clinics

    International Nuclear Information System (INIS)

    Vorob'ev, I.B.; Krivokhatskij, A.S.; Nekrasov, E.V.; Nikolaev, V.A.; Potapov, V.G.; Terent'ev, M.V.

    1990-01-01

    Usability of a new equipment-technique combination for measuring radon activity in the air of radon laboratories and balneological clinics is studied. The complex includes nitrate-cellulose detector, radon chamber, Aist, Istra type spark counters and technique of spark counting. The method sensitivity is 50 Bqxm 3 , the error is 30%. Usability and advisability of track method in radon laboratories and balneological clinics for simultaneous measurement in several points of integral volumetric radon activities are confirmred. The method permits to carry out rapid and accurate bulk investigations. The results of determining mean volumetric radon activity in the air in different points of radon laboratory and radon clinics are presented

  19. The rationale and experiences in implementing New Jersey's radon program

    International Nuclear Information System (INIS)

    Bynum, J.; Klotz, J.; Cahill, M.; Nicholls, G.

    1988-01-01

    The authors discuss how radon data from domestic modeling, mining studies, and animal studies provided a strong basis for New Jersey Department of Health (NJDOH) to support MJDEP's recommendation to establish a state radon program. The program, described in this report, focuses on promoting intensive testing by state residents followed by prompt remediation for residences with radon levels greater than or equal to four pico curies per liter. NJDOH believes a threshold for radiation carcinogens does not exist. Even at low levels, exposure to radiation is associated with some health risk. Hence, with consideration given to the length of exposure in the home prompt action is warranted until more definitive data suggest otherwise

  20. Indoor radon pollution: Control and mitigation. June 1978-December 1989 (Citations from the NTIS data base). Report for June 1978-December 1989

    International Nuclear Information System (INIS)

    1990-01-01

    This bibliography contains citations concerning the control and mitigation of radon pollution in homes and commercial buildings. Citations cover radon transport studies in buildings and soils, remedial action proposals on contaminated buildings, soil venting, building ventilation, sealants, filtration systems, water degassing, reduction of radon sources in building materials, and evaluation of existing radon mitigation programs including their cost effectiveness. Analysis and detection of radon and radon toxicity are covered in separate published bibliographies. (Contains 129 citations fully indexed and including a title list.)

  1. Effectiveness of interim remedial actions at a radioactive waste facility

    International Nuclear Information System (INIS)

    Devgun, J.S.; Beskid, N.J.; Peterson, J.M.; Seay, W.M.; McNamee, E.

    1989-01-01

    Over the past eight years, several interim remedial actions have been taken at the Niagara Falls Storage Site (NFSS), primarily to reduce radon and gamma radiation exposures and to consolidate radioactive waste into a waste containment facility. Interim remedial actions have included capping of vents, sealing of pipes, relocation of the perimeter fence (to limit radon risk), transfer and consolidation of waste, upgrading of storage buildings, construction of a clay cutoff wall (to limit the potential groundwater transport of contaminants), treatment and release of contaminated water, interim use of a synthetic liner, and emplacement of an interim clay cap. An interim waste containment facility was completed in 1986. 6 refs., 3 figs

  2. Comparison of five-minute radon-daughter measurements with long-term radon and radon-daughter concentrations

    International Nuclear Information System (INIS)

    Young, J.A.; Jackson, P.O.; Thomas, V.W.

    1983-01-01

    Five-minute air filter radon daughter measurements were made in 84 buildings in Edgemont, South Dakota, in which annual average radon daughter concentrations have been determined from six 100-hour Radon Progeny Integrating Sampling Unit (RPISU) measurements. Averaging radon concentrations were also determined in 50 of these buildings using Terradex Track Etch detectors. The standard deviation of the difference between the (natural) logarithms of the RPISU annual averages and the logarithms of the air filter measurements (SD-ln) was found to be 0.52. This SD-ln is considerably smaller than the SD-ln of 0.71 between the RPISU annual averages and the air filter measurements reported by ALARA at Grand Junction, Colorado; presumably because a considerable number of air filter measurements in Edgemont were disregarded because of short turnover times or high wind speeds. Using the SD-ln of 0.52 it can be calculated that there would only be a 5% probability in Edgemont that the RPISU annual average would be greater than 0.015 WL if the five-minute measurement were equal to 0.010 WL. This indicates that the procedure used in Edgemont of clearing buildings from remedial action if the five-minute measurement were less than 0.010 WL was reasonable. There was about a 28% probability that the RPISU annual average would be less than 0.015 WL if the five-minute measurement were 0.033 WL, indicating that the procedure of performing an engineering assessment if the average of two five-minute measurements was greater than 0.033 WL was also reasonable. Comparison indicates that the average of two RPISU measurements taken six months apart would provide a dependable estimate of the annual average

  3. A condensed water method for measuring the atmospheric radon

    CERN Document Server

    Wu Xin; Pan Xiao Qing; Yu Yi Ling

    1998-01-01

    The author summarizes the present situation of atmospheric Radon measurement, and introduces the working principle, working method and advantage and disadvantage of condensed water method in detail. The structure and function of the instrument used for this method, and the measuring result are discussed. The direction of further work is pointed out from now on

  4. A Laboratory for studying radon mitigation methods in high-rise office buildings in Hong Kong

    International Nuclear Information System (INIS)

    Leung, J.K.C.; Hung, L.C.; Tso, M.Y.W.

    1996-01-01

    A territory-wide survey of indoor radon level in 1993 showed that 17% of offices Hong Kong have radon concentrations above 200 Bq m -3 compared with 4% for dwellings. Consequently, the Radioisotope Unit Radon Analysis Laboratory (RURAL) is being built for studying radon mitigation methods applicable to high-rise office buildings. The laboratory consists of three rooms; the main exposure room is built of concrete and is surrounded by the buffer room; and all controls and operations are done inside the control room. The exposure room can, with the aid of the buffer room, simulate any environmental conditions that can be faced by a real building. The pressure, temperature and humidity can be adjusted to any meteorological conditions that can be found in Hong Kong. Pressure differential and temperature differential can be adjusted to simulate the arrival of fronts, troughs or typhoons. Aerosol concentration and distribution inside the exposure room are controllable as well as the ventilation conditions. Various mitigation methods will be tested under different conditions. Passive methods include application of radon barriers to building structures and active methods include the use of air cleaners; techniques to increase radon daughters plateout or reduce their attachment to aerosols; and various modifications to the ventilation systems. Mitigation techniques involving modifications to the building strictures and building services will also be developed with the help of the RURAL. (author)

  5. Development of measure methods of radon in indoor air

    International Nuclear Information System (INIS)

    Yaginuma, L.T.; Pela, C.A.; Navas, E.A.; Ghilardi, A.J.P.

    1992-01-01

    The development of some conventional measuring methods, aiming obtain an estimation of radon concentration in air, mainly in indoor air is described, including the charcoal absorption collector, Lucas cell and thermoluminescent dosemeters. (C.G.C)

  6. Study of Behavior and detection of radon in environmental samples by scintillation method. Application for radium

    International Nuclear Information System (INIS)

    ZAFIMANJATO, J.L.R.

    2007-01-01

    Radon is considered as the major source of radiological exposure of natural radiations to the population. On an international scale, it represents about the half of exposures of natural radiation sources (UNSCEAR, 1993) Radon gets into human body with inhaled air and sometimes with drinking water. Then, the objective of this work is to know the radon concentrations in water and in indoor atmosphere, and the risk in order to set up a method of monitoring and to identify high radon level areas. A specific method of detection using liquid scintillation with special emphasis on α/β discrimination, the use of solvent extractive and enrichment of radionuclides have been developed for the determination of both 222 Rn and 226 Ra in water. The method is simple, rapid and sensitive. In a pilot project for a monitoring of drinking water in Madagascar, it was shown that the proposed method was suitable for a large scale monitoring and routine analysis. Considerable concentrations of radon were found in water and air samples from Vinaninkarena. Radon concentrations obtained by in situ and in laboratory measurements have been compared to the results of an international intercomparison campaigns organised by the German Society for Liquid Scintillation Spectrometry in 2011. A theoretical study of the behavior of radon is porous material containing radium is detailed in order to describe its exhalation phenomena. An assessment model of the dose due to ingestion and liberation of radon from water is presented and compared with other models especially to the Crawford Brown's model. [fr

  7. Monitoring of the radon exposure in workplaces: Regulatory approaches

    International Nuclear Information System (INIS)

    Ettenhuber, E.

    2002-01-01

    Germany has a reference level of 2 10 6 Bqh/m 3 for radon in workplaces, corresponding to an annual dose of 6 mSv and a limit of 6 10 6 Bqh/m 3 , corresponding to 10 mSv/y. If the reference level is exceeded remedial action has to be taken and a new radon measurement should be carried out. If it is not possible to reduce the radon concentration below the reference level the competent authority has to be notified and monitoring of the radon concentrations performed. Germany has performed a study to investigate the exposure by natural radionuclides in workplaces in a large number of industrial activities, with a dose assessment of the workers under normal circumstances. They made a categorization of NORM activities in dose ranges of 20 mSv/y. Most of the NORM activities fall in the category <1 mSv/y when normal occupational hygiene measures are taken

  8. Standardization of radon measurements

    International Nuclear Information System (INIS)

    Matuszek, J.M.; Hutchinson, J.A.; Lance, B.H.; Virgil, M.G.; Mahoney, R.J.

    1988-01-01

    Radon escaping from soil into homes appears to present the single greatest source of radiation exposure that most people will ever face. Measurement protocols for the relatively inert gas inextricably link the method of collection with the counting of the specimen. The most commonly used methods depend on the measurement of dislocation sites on plastic α-track detectors or on the adsorption of radon onto activated charcoal for subsequent counting of the γ-rays produced by decay of the radon progeny. The uncertainties inherent to the radon-measurement methods used commercially in the United States are far greater than those for measurements of other environmental radionuclides. The results of this preliminary study raise doubts as to whether existing proficiency-testing programs can provide assurance that radon-measurement methods are representative of actual conditions in any dwelling. 17 refs., 1 figs., 4 tabs

  9. New method and installation for rapid determination of radon diffusion coefficient in various materials

    International Nuclear Information System (INIS)

    Tsapalov, Andrey; Gulabyants, Loren; Livshits, Mihail; Kovler, Konstantin

    2014-01-01

    The mathematical apparatus and the experimental installation for the rapid determination of radon diffusion coefficient in various materials are developed. The single test lasts not longer than 18 h and allows testing numerous materials, such as gaseous and liquid media, as well as soil, concrete and radon-proof membranes, in which diffusion coefficient of radon may vary in an extremely wide range, from 1·10 −12 to 5·10 −5 m 2 /s. The uncertainty of radon diffusion coefficient estimation depends on the permeability of the sample and varies from about 5% (for the most permeable materials) to 40% (for less permeable materials, such as radon-proof membranes). - Highlights: • The new method and installation for determination of radon diffusion coefficient D are developed. • The measured D-values vary in an extremely wide range, from 5×10 -5 to 1×10 -12 m 2 /s. • The materials include water, air, soil, building materials and radon-proof membranes. • The duration of the single test does not exceed 18 hours. • The measurement uncertainty varies from 5% (in permeable materials) to 40% (in radon gas barriers)

  10. Measurement of radon concentration in water using the portable radon survey meter.

    Science.gov (United States)

    Yokoyama, S; Mori, N; Shimo, M; Fukushi, M; Ohnuma, S

    2011-07-01

    A measurement method for measuring radon in water using the portable radon survey meter (RnSM) was developed. The container with propeller was used to stir the water samples and release radon from the water into the air in a sample box of the RnSM. In this method, the measurement of error would be water was >20 Bq l(-1).

  11. Progress report on the Grand Junction uranium mill tailings remedial action program

    International Nuclear Information System (INIS)

    1979-02-01

    The report provides a history of the program, an analysis of the current status of the program, problems encountered and measures being taken to solve them, and a forecast of future effort required. From the start of remedial efforts in 1973 through September 30, 1978, remedial action has been done on 325 individual structures, including 289 private residences, 14 schools, and 22 commercial business/church locations. As recently as one year ago, the total number of structures requiring remedial action was estimated to be about 600. However, continuing measurements of radon daughter concentrations in structures which previously showed only slightly elevated gamma radiation have resulted in identificaion of additional structures exceeding the Surgeon General's guidelines for radon daughters. Because radon daughter concentrations in structures are highly variable depending on the season of the year and the level of activity, annual averages are used for determining eligibility under the guidelines. Based on this recent experience the estimate of the total number of structures which will eventually qualify for remedial action has been increased from 600 to 800, and the estimated total program cost has been increased from $12,670,000 to $16,960,000. It must be emphasized that these estimates are based only on experience ratios of past measurements and are highly uncertain. It is not expected that further funding, if necessary, will be required before fiscal year 1982

  12. Measurement of the radon exhalation rate from the medium surface by tracing the radon concentration

    International Nuclear Information System (INIS)

    Yanliang Tan; Detao Xiao

    2013-01-01

    The paper will present a method based on the accumulation chamber technique for measuring of radon exhalation from the medium surface. A radon monitor traces the change of radon concentration in the accumulation chamber, and then the radon exhalation can be obtained accurately through linear fit. Based on our recent experiments, the radon exhalation rate from the medium surface obtained from this method is in good agreement with the actual exhalation rate of our simulation facility. This method is superior to the competition method which obtains the radon exhalation through the exponential fit by an external PC-system. The calculation for the exponential fit is very easy by computer and related software. However, for portable instruments, the single chip microcomputer can't calculate the exponential fit rapidly. Thus, this method is usable for developing the new portable instrument to classify building materials, etc. (author)

  13. Radon reduction and radon-resistant construction demonstrations in New York state. Final report

    International Nuclear Information System (INIS)

    1991-02-01

    A survey of radon levels in New York State homes indicates that approximately 4.4 percent of the homes have long-term living area radon concentrations above the U.S. EPA guideline of four pCi/l. The project addressed the effectiveness of techniques to reduce the radon level in existing homes and to prevent the occurrence of high radon concentrations in new homes. The goal of the project was to demonstrate the effectiveness of radon reduction techniques in homes containing indoor radon concentrations of more than the current EPA guidelines of four pCi/l. At the same time, radon-resistant construction techniques were demonstrated in homes under construction to provide guidelines for houses being built in areas with a danger of high radon levels. The project demonstrated new radon mitigation techniques in homes containing indoor radon concentrations exceeding four pCi/l; assessed the value of previously installed radon reduction procedures, and demonstrated new radon-resistant construction methods

  14. Dose assessment of remedial action for uranium tailing impoundment of a nuclear factory

    International Nuclear Information System (INIS)

    Li Xutong; Ma Ruwei; Guo Zede

    2000-01-01

    A large uranium tailing impoundment in China will be closure and remedial action have been planned. The remedial action will include shaping and covering the dam and beach in order to prevent the impoundment from damage and restrict spread of tailing sands and emission of radon. The author presents the analysis and estimation of the exposure to workers for remedial action and to public after the remedial action. To estimate the exposure to workers, the pathway of inhalation of radon, tailing sands in suspension and external γ exposure were taken into consideration. The exposure scenario is considered as probably maximum exposure to the workers who work on the tailing pile without any protection measures, the dose is 6.0 mSv/a. Two situation for the exposure to public after remedial action were considered: normal and abnormal condition. For the normal condition, inhalation of radon emitted from impoundment is only the pathway to public for the exposure, and individual dose for critical group of public is 0.053 mSv/a, collective dose for population within 80 km is 1.0 man·Sv/a. For the abnormal conditions, four scenarios were considered, i.e. dwelling on tailing pile, farming on tailing pile, living in a house built by contaminated materials and some temporal activities on the pile. The scenarios of dwellings is living in a house on the pile and drinking contaminated water. The maximum individual dose is 27 mSv/a

  15. Conveyancing implications of radon in homes in England and Wales

    International Nuclear Information System (INIS)

    Adams, J.

    1992-01-01

    In general the principle of caveat emptor (buyer beware) applies to house purchase. There are exceptions to this rule, but it seems unlikely that they will apply to radon unless the seller has been made a statement about radon, either voluntarily or in answer to questions. If the seller makes a false statement, the buyer has remedies in law. In future it may be that solicitors will be held to be negligent if they do not ask questions about radon in high-risk areas, but we have not reached that situation yet. A change of policy by mortgage lenders could change matters. Once lenders are seen to be alert to the problems, buyers' solicitors will not be able to afford to keep quiet about them either. (Author)

  16. Radon therapy; Radon in der Therapie

    Energy Technology Data Exchange (ETDEWEB)

    Spruck, Kaija [Technische Hochschule Mittelhessen, Giessen (Germany). Inst. fuer Medizinische Physik und Strahlenschutz

    2017-04-01

    Radon therapies are used since more than 100 years in human medicine. Today this method is controversially discussed due to the possible increase of ionizing radiation induced tumor risk. Although the exact mode of biological radiation effect on the cell level is still not known new studies show the efficiency of the radon therapy without side effect for instance for rheumatic/inflammatory or respiratory disorders.

  17. Characterization of radon penetration of different structural domains of concrete. Final project report

    International Nuclear Information System (INIS)

    Nielson, K.K.; Rogers, V.C.

    1996-05-01

    This report documents the research activities by Rogers and Associates Engineering Corporation on grant DE-FG03-93ER61600 during the funded project period from August 1993 to April 1996. The objective of this research was to characterize the mechanisms and rates of radon gas penetration of the different structural domains of the concrete components of residential floor slabs, walls, and associated joints and penetrations. The research was also to characterize the physical properties of the concretes in these domains to relate their radon resistance to their physical properties. These objectives support the broader goal of characterizing which, if any, concrete domains and associated properties constitute robust barriers to radon and which permit radon entry, either inherently or in ways that could be remediated or avoided

  18. Radon and its hazards

    International Nuclear Information System (INIS)

    Chang Guilan

    2002-01-01

    The author describes basic physical and chemical properties of radon and the emanation, introduces methods of radon measurement, expounds the hazards of non-mine radon accumulation to the health of human being and the protection, as well as the history how the human being recognizes the hazards of radon through the specific data and examples, and finally proposes protecting measures to avoid the hazards of radon to the health of human being, and to do ecologic evaluation of environments

  19. Psychosocial aspects of Czech Radon Programme

    International Nuclear Information System (INIS)

    Fojtikova, I.; Neznal, M.; Hrdy, L.

    2004-01-01

    In November 1999 a radon awareness survey was conducted among Czech republic residents to evaluate their general awareness and the factual knowledge about radon, radon measurements and radon mitigation. This survey, however, did not provide any detailed information on whether the respondents' knowledge is deep and structured or it is just a chaotic mixture of impressions. Therefore, a new survey was conducted from May to November 2001. About 20 respondents, in whose houses the long term testing for radon levels had just been finished, were interviewed. The in-depth interviews had several main aims: a) to obtain a more detailed understanding of their general awareness and factual knowledge about radon; b) to learn more about the sources of their knowledge and of their perception of the radon risk; c) to get information as to whether householders accept radon remediation, and to identify any personal, attitudinal or other variables that can influence the householder's decision; and d) to experience the direct risk communication and conceive its effectiveness. The interviews confirmed some results of the former quantitative study, e.g. increasing knowledge correlating with increasing education level. They showed that the public, overloaded with information, is not disposed to search actively for other information sources (e.g. on the Internet). People perceive their knowledge as adequate and sufficient. Their approach to gathering information is very passive. Therefore, to enhance public understanding of radiation phenomena it is necessary to make efforts, including the use of public media, otherwise radioactivity will remain shrouded in myths. These myths often lead to underestimation of the radon risk. A typical example of such underestimation is a contention that there exist long-aged healthy people who live in extreme radon concentrations. Together with the interviews, a questionnaire describing 11 presumably risky situations or practices was used. Among other

  20. A method for purifying air containing radioactive substances resulting from the disintegration of radon

    International Nuclear Information System (INIS)

    Stringer, C.W.

    1974-01-01

    The invention relates to the extraction of radioactive isotopes from air. It refers to a method for withdrawing the radioactive substances resulting from the disintegration of radon from air, said method of the type comprising filtrating the air contaminated by the radon daughter products in a filter wetted with water in order to trap said substances in water. It is characterized in that it comprises the steps of causing the water contaminated by the radon daughter products to flow through a filtrating substance containing a non hydrosoluble granular substrate, the outer surface of which has been dried then wetted by a normally-liquid hydrocarbon, and of returning then wetted by a normally-liquid hydrocarbon, and of returning the thus filtrated water so that it wets again the air filter and entraps further radon daughter products. This can be applied to the purification of the air in uranium mines [fr

  1. Comparison of retrospective and contemporary indoor radon measurements in a high-radon area of Serbia

    International Nuclear Information System (INIS)

    Zunic, Z.S.; Yarmoshenko, I.V.; Kelleher, K.; Paridaens, J.; Mc Laughlin, J.P.; Celikovic, I.; Ujic, P.; Onischenko, A.D.; Jovanovic, S.; Demajo, A.; Birovljev, A.; Bochicchio, F.

    2007-01-01

    In Niska Banja, Serbia, which is a high-radon area, a comparison was made between two retrospective radon measuring methods and contemporary radon measurements. The two retrospective methods derive the radon concentrations that occurred in dwellings over longer periods in the past, based on the amount of trapped 210 Po on the surface of glass objects (surface traps, ST) or in the bulk of porous materials (volume traps, VT). Both surface implanted 210 Po in glass objects and contemporary radon in air were measured in 46 rooms, distributed in 32 houses of this radon spa-town, using a dual alpha track detector configuration (CR-39 and LR115) and CR-39 track etched detectors, respectively. In addition to the use of surface trap measurements, in 18 rooms (distributed in 15 houses) VT samples of suitable material were also collected, allowing to compare ST and VT retrospective radon concentration estimates. For each room, contemporary annual radon concentrations (CONT) were measured or estimated using seasonal correction factors. The distribution of the radon concentration in all data sets was found to be close to lognormal (Chi-square test > 0.05). Geometric means (GM) are similar, ranging from 1040 to 1380 Bq m -3 , whereas geometric standard deviations (GSD) for both the retrospective methods are greater than for the CONT method, showing reasonable agreement between VT, ST and CONT measurements. A regression analysis, with respect to the lognormal distribution of each data set, shows that for VT-ST the correlation coefficient r is 0.85, for VT-CONT r is 0.82 and for ST-CONT r is 0.73. Comparison of retrospective and contemporary radon concentrations with regard to supposed long-term indoor radon changes further supports the principal agreement between the retrospective and conventional methods

  2. A remedial alternative prioritization method

    International Nuclear Information System (INIS)

    Richter, S.A.; Travis, C.C.

    1987-01-01

    This study develops and tests a technique for evaluating and prioritizing alternative remedial actions for hazardous waste sites. The method is based on criteria involving risk, benefit and cost, and identifies the most cost-effective solution to a given remedial problem. Four sites on the Department of Energy's Oak Ridge National Laboratory (ORNL) property in Oak Ridge, Tennessee, were used in a case study to develop and test the method. Results of the case study indicate that even if the cap providing in situ containment must be replaced every 10 years, it is a superior alternative to total excavation of the waste sites

  3. 1981 radon barrier field test at Grand Junction uranium mill tailings pile

    International Nuclear Information System (INIS)

    Hartley, J.N.; Gee, G.W.; Baker, E.G.; Freeman, H.D.

    1983-04-01

    Technologies to reduce radon released from uranium mill tailings are being investigated by Pacific Northwest Laboratory as part of the Department of Energy's Uranium Mill Tailings Remedial Action Project (UMTRAP) Technology development program. These technologies include: (1) earthen cover systems, (2) multilayer cover systems, and (3) asphalt emulsion radon barrier systems. During the summer of 1981, a field test was initiated at the Grand Junction, Colorado, uranium tailings pile to evaluate and compare the effectiveness of each radon barrier system. Test plots cover about 1.2 ha (3 acres). The field test has demonstrated the effectiveness of all three cover systems in reducing radon release to near background levels ( 2 s - 1 ). In conjunction with the field tests, column tests (1.8 m diameter) were initiated with cover systems similar to those in the larger field test plots. The column tests allow a direct comparison of the two test procedures and also provide detailed information on radon transport

  4. Radon mitigation in schools

    International Nuclear Information System (INIS)

    Leovic, K.W.; Craig, A.B.; Saum, D.W.

    1990-01-01

    This article reports on radon mitigation in school buildings. Subslab depressurization (SSD) has been the most successful and widely used radon reduction method in houses. Thus far, it has also substantially reduced radon levels in a number of schools. Schools often have interior footings or thickened slabs that may create barriers for subslab air flow if a SSD system is the mitigation option. Review of foundation plans and subslab air flow testing will help to determine the presence and effect of such barriers. HVAC systems in schools vary considerable and tend to have a greater influence on pressure differentials (and consequently radon levels) than do heating and air-conditioning systems encountered in the radon mitigation of houses. As part of any radon mitigation method, ASHRAE Standard 62-1989 should be consulted to determine if the installed HVAC system is designed and operated to achieve minimum ventilation standards for indoor air quality

  5. S. 1697: A Bill to require local educational agencies to conduct testing for radon contamination in schools, and for other purposes. Introduced in the Senate of the United States, One Hundredth First Congress, Second Session, October 22, 1990

    International Nuclear Information System (INIS)

    Anon.

    1990-01-01

    This bill was introduced into the U.S. Senate on September 28, 1989 to require local educational agencies to conduct testing for radon contamination in schools. Studies indicate that 54% of schools tested have at least one room with elevated levels of radon and that over 20% of all school rooms tested had elevated levels of radon. There is a need for improved information on proper methods and procedures for testing and remediation of radon in school buildings. In addition, there is a need for the federal government to provide financial assistance to states and local educational agencies for implementation of measures to reduce elevated levels of radon

  6. Multiple attenuation to reflection seismic data using Radon filter and Wave Equation Multiple Rejection (WEMR) method

    Energy Technology Data Exchange (ETDEWEB)

    Erlangga, Mokhammad Puput [Geophysical Engineering, Institut Teknologi Bandung, Ganesha Street no.10 Basic Science B Buliding fl.2-3 Bandung, 40132, West Java Indonesia puput.erlangga@gmail.com (Indonesia)

    2015-04-16

    Separation between signal and noise, incoherent or coherent, is important in seismic data processing. Although we have processed the seismic data, the coherent noise is still mixing with the primary signal. Multiple reflections are a kind of coherent noise. In this research, we processed seismic data to attenuate multiple reflections in the both synthetic and real seismic data of Mentawai. There are several methods to attenuate multiple reflection, one of them is Radon filter method that discriminates between primary reflection and multiple reflection in the τ-p domain based on move out difference between primary reflection and multiple reflection. However, in case where the move out difference is too small, the Radon filter method is not enough to attenuate the multiple reflections. The Radon filter also produces the artifacts on the gathers data. Except the Radon filter method, we also use the Wave Equation Multiple Elimination (WEMR) method to attenuate the long period multiple reflection. The WEMR method can attenuate the long period multiple reflection based on wave equation inversion. Refer to the inversion of wave equation and the magnitude of the seismic wave amplitude that observed on the free surface, we get the water bottom reflectivity which is used to eliminate the multiple reflections. The WEMR method does not depend on the move out difference to attenuate the long period multiple reflection. Therefore, the WEMR method can be applied to the seismic data which has small move out difference as the Mentawai seismic data. The small move out difference on the Mentawai seismic data is caused by the restrictiveness of far offset, which is only 705 meter. We compared the real free multiple stacking data after processing with Radon filter and WEMR process. The conclusion is the WEMR method can more attenuate the long period multiple reflection than the Radon filter method on the real (Mentawai) seismic data.

  7. Radon monitoring technique with electret collecting

    International Nuclear Information System (INIS)

    Tian Zhiheng; Zuo Fuqi; Xiao Detao; Zhao Xkiuliang

    1991-12-01

    The integrating radon monitoring technique with electret collecting is a method which collects the 218 Po + positive ions by electrostatic field produced by electret. It has greatly improved the sensitivity of radon measurement. The response factor of this method reaches to 4.7 cm -2 Bq -1 m 3 h -1 , 1000 times larger than that of common passive sampling method. The monitoring device and its principle are introduced. The measuring results of radon concentration and radon flux rate and quality assurance system by using this method in the Qinshan Nuclear Power Plant, Human Environmental Monitoring Central Station and some uranium mines are also presented. The analytical results show that the radon concentration in the Qinshan Nuclear Power Plant is affected by wind direction. When wind directs toward sea, the radon concentration is high. If the wind is to the contrary, it is low. The radon concentration ratio of both is about 2

  8. Tracing and quantifying groundwater inflow into lakes using a simple method for radon-222 analysis

    Directory of Open Access Journals (Sweden)

    T. Kluge

    2007-09-01

    Full Text Available Due to its high activities in groundwater, the radionuclide 222Rn is a sensitive natural tracer to detect and quantify groundwater inflow into lakes, provided the comparatively low activities in the lakes can be measured accurately. Here we present a simple method for radon measurements in the low-level range down to 3 Bq m−3, appropriate for groundwater-influenced lakes, together with a concept to derive inflow rates from the radon budget in lakes. The analytical method is based on a commercially available radon detector and combines the advantages of established procedures with regard to efficient sampling and sensitive analysis. Large volume (12 l water samples are taken in the field and analyzed in the laboratory by equilibration with a closed air loop and alpha spectrometry of radon in the gas phase. After successful laboratory tests, the method has been applied to a small dredging lake without surface in- or outflow in order to estimate the groundwater contribution to the hydrological budget. The inflow rate calculated from a 222Rn balance for the lake is around 530 m³ per day, which is comparable to the results of previous studies. In addition to the inflow rate, the vertical and horizontal radon distribution in the lake provides information on the spatial distribution of groundwater inflow to the lake. The simple measurement and sampling technique encourages further use of radon to examine groundwater-lake water interaction.

  9. Mineral dusts and radon in uranium mines

    International Nuclear Information System (INIS)

    Abelson, P.H.

    1991-01-01

    The Environmental Protection Agency (EPA) continues to assert that radon is a major cause of lung cancer in this country. EPA is fostering a radon program that could entail huge financial and emotional costs while yielding negligible benefits to public health. Justification for the program was the occurrence of lung cancer in men exposed to huge amounts of radon, mineral dusts, and other lung irritants in uranium mines on the Colorado Plateau. Lung cancer has been reported in about 356 cigarette smokers and in about 25 nonsmokers. During the era of high radon levels, monitoring was sporadic. Conditions in only a small fraction of the mines were measured, and that on a few separate occasions. Later, cumulative exposure to radon was calculated on the basis of measurements involving only a tiny fraction of the miners. Some were exposed to more than 15,000 pCi/liter of radon and its products. The level in the average home is about 1.5 pCi/liter. In making extrapolations from mine to home, the assumption is made that residents are in their dwellings most of the time and that miners spend only 170 hours a month in the mine. Two major questionable assumptions are involved in extrapolations from high doses of radon in the mines to low doses in homes. One is that no threshold is involved; that is, that humans have no remediation mechanism for α particle damages. There is evidence to the contrary. The most unrealistic assumption is that heavy exposure to silica has no effect on inducing lung cancer. Many studies have shown that silica dust causes lung cancer in animals. Exposure of human culture cells to silica has resulted in formation of neoplastic tissue. EPA has no solid evidence that exposures to 4 pCi/liter of radon causes lung cancer in either smokers or nonsmokers. Indeed, there is abundant evidence to the contrary in the fact that in states with high levels of radon, inhabitants have less lung cancer than those in states with low levels

  10. Experience based on practice to improve the radon-situation in Saxony. A personal retrospect and outlook for young radiation protection engineers; Erfahrungen aus praktischer Taetigkeit zur Verbesserung der Radon-Situation in Sachsen. Ein persoenlicher Rueckblick und Perspektiven fuer junge Strahlenschuetzer

    Energy Technology Data Exchange (ETDEWEB)

    Loebner, Walfried

    2015-07-01

    Based on the state of knowledge and international developments concerning the radon situation in dwellings the experiences regarding the improvement of the radon situation in Saxony were described as a personal retrospect of more than 20 years practice. The taken path to control the radon situation in German dwellings has been reflected as a personally point of view. Open questions and controversial issues were named. The practical experiences in handling of radon in dwellings in connection with the remediation activities at uranium mining legacies were described. As conclusions drawn on own activities and insights the future challenges to improve the radon situation in Saxony were outlined. An outlook was directed to the young radiation protection engineers and civil engineers.

  11. How dangerous is radon in buildings? - Some reflections from Europe

    International Nuclear Information System (INIS)

    Becker, K.

    1994-01-01

    ICRP published recommendations on indoor radon in 1987. Based on the suggested action levels for new and existing houses of 200 and 400 Bq/m 3 , various countries established levels of their own which vary between 150 Bq/m 3 in the United States, and 200-250 in most European countries. In 1989, the ICRP Task Group responsible for radon proposed another increase of the risk factors by about a factor of three. This would imply more radon-induced lung cancers in certain nonsmoking population groups than are totally observed. On the other hand, there is an increasing number of scientists who seriously question the validity of the ICRP assumptions, and all the more or less official governmental actions based on them -- including the substantial socioeconomic impact of remedial measures which would be required in high-radon areas. In this editorial the author discusses some cases in which people have exposed themselves to radon for its supposedly therapeutic effects and have not apparently suffered an increase in health problems as would have been expected based on data of lung cancer in uranium miners. The author discusses the complexity of determining the health hazards of radon gas and the associated problems of establishing safe exposure limits. 11 refs

  12. A computer method for simulating the decay of radon daughters

    International Nuclear Information System (INIS)

    Hartley, B.M.

    1988-01-01

    The analytical equations representing the decay of a series of radioactive atoms through a number of daughter products are well known. These equations are for an idealized case in which the expectation value of the number of atoms which decay in a certain time can be represented by a smooth curve. The real curve of the total number of disintegrations from a radioactive species consists of a series of Heaviside step functions, with the steps occurring at the time of the disintegration. The disintegration of radioactive atoms is said to be random but this random behaviour is such that a single species forms an ensemble of which the times of disintegration give a geometric distribution. Numbers which have a geometric distribution can be generated by computer and can be used to simulate the decay of one or more radioactive species. A computer method is described for simulating such decay of radioactive atoms and this method is applied specifically to the decay of the short half life daughters of radon 222 and the emission of alpha particles from polonium 218 and polonium 214. Repeating the simulation of the decay a number of times provides a method for investigating the statistical uncertainty inherent in methods for measurement of exposure to radon daughters. This statistical uncertainty is difficult to investigate analytically since the time of decay of an atom of polonium 218 is not independent of the time of decay of subsequent polonium 214. The method is currently being used to investigate the statistical uncertainties of a number of commonly used methods for the counting of alpha particles from radon daughters and the calculations of exposure

  13. Radon barrier field-test monitoring at Grand Junction tailings pile

    International Nuclear Information System (INIS)

    Freeman, H.D.; Hartley, J.N.; Gee, G.W.

    1983-11-01

    Pacific Northwest Laboratory (PNL), as part of the Department of Energy (DOE) Uranium Mill Tailings Remedial Action Project (UMTRAP) technology development program, has conducted three large-scale field tests of radon covers at the uranium mill tailings pile in Grand Junction, Colorado. The barrier systems, monitored for radon flux for over two years, include earthen, multilayer, and asphalt emulsion covers. Results of the monitoring have shown that a variety of cover systems can meet the Environmental Protection Agency (EPA) standard. The most effective covers tested were asphalt emulsion and earthen (mancos shale). 10 references, 7 figures, 1 table

  14. Determination of air-loop volume and radon partition coefficient for measuring radon in water sample.

    Science.gov (United States)

    Lee, Kil Yong; Burnett, William C

    A simple method for the direct determination of the air-loop volume in a RAD7 system as well as the radon partition coefficient was developed allowing for an accurate measurement of the radon activity in any type of water. The air-loop volume may be measured directly using an external radon source and an empty bottle with a precisely measured volume. The partition coefficient and activity of radon in the water sample may then be determined via the RAD7 using the determined air-loop volume. Activity ratios instead of absolute activities were used to measure the air-loop volume and the radon partition coefficient. In order to verify this approach, we measured the radon partition coefficient in deionized water in the temperature range of 10-30 °C and compared the values to those calculated from the well-known Weigel equation. The results were within 5 % variance throughout the temperature range. We also applied the approach for measurement of the radon partition coefficient in synthetic saline water (0-75 ppt salinity) as well as tap water. The radon activity of the tap water sample was determined by this method as well as the standard RAD-H 2 O and BigBottle RAD-H 2 O. The results have shown good agreement between this method and the standard methods.

  15. Determination of air-loop volume and radon partition coefficient for measuring radon in water sample

    International Nuclear Information System (INIS)

    Kil Yong Lee; Burnett, W.C.

    2013-01-01

    A simple method for the direct determination of the air-loop volume in a RAD7 system as well as the radon partition coefficient was developed allowing for an accurate measurement of the radon activity in any type of water. The air-loop volume may be measured directly using an external radon source and an empty bottle with a precisely measured volume. The partition coefficient and activity of radon in the water sample may then be determined via the RAD7 using the determined air-loop volume. Activity ratios instead of absolute activities were used to measure the air-loop volume and the radon partition coefficient. In order to verify this approach, we measured the radon partition coefficient in deionized water in the temperature range of 10-30 deg C and compared the values to those calculated from the well-known Weigel equation. The results were within 5 % variance throughout the temperature range. We also applied the approach for measurement of the radon partition coefficient in synthetic saline water (0-75 ppt salinity) as well as tap water. The radon activity of the tap water sample was determined by this method as well as the standard RAD-H 2 O and BigBottle RAD-H 2 O. The results have shown good agreement between this method and the standard methods. (author)

  16. Radon levels after restoration of the U-mine disposal site

    International Nuclear Information System (INIS)

    Krizman, M.J.; Rojc, J.; Jovanovic, P.

    2010-01-01

    After cessation of the underground mining of uranium ore and production of uranium concentrate at Zirovski Vrh (Slovenia) in the period 1985-1990, two permanent surface disposal sites remained, namely, tailings pile and mine waste rock pile. Both disposal sites were of equal size of 4 hectares and were significant sources of radon. Their final restoration was designed in compliance with the condition of dose constraint for the public and authorized limits for radon exhalation from the remediated piles. In the late summer of 2008, a restoration of the mine waste pile was finished. Radon releases were reduced significantly by constructing an effective radon barrier of well compacted clay material and a thick complex protective cover layer constructed over it. Radon exhalation rate from the mine waste area was lowered from primary level of 0.7 Bq/m 2 ·s to natural levels (0.01 Bq/m 2 ·s), and consequently, ambient radon levels also decreased on the site and nearby environment. The average radon contribution from the remaining U-mine sources was estimated on the basis of the environmental measurements of radon concentrations; they dropped from initial 7-9 Bq/m 3 to approximately 3 Bq/m 3 . Further reduction of outdoor radon concentrations is expected after 2010, since the restoration of another disposal site will have been completed by the end of this year. Public exposure due to industrial radon after the first phase of restoration satisfactorily meets the dose constraint level of 0.3 mSv/y, since it decreased to less than 0.1 mSv/y. (authors)

  17. protection against radon at home and at work; recommendations of the Israel national advisory committee on radiation protection and their practical implementation

    International Nuclear Information System (INIS)

    Schlesinger, T.; Margaliot, M.

    1997-01-01

    Existing legislation in Israel related to protection of the worker and the public from ionizing radiation excludes certain natural radiation sources from control by national authorities. Among these sources are radon and radon daughters. Employers are not required, by law to intervene in order to reduce radon levels in the working place, even when these levels exceed the action levels recommended by the ICRP or by the International Basic Safety Standards for protection Against Ionizing radiation. The Israel National Advisory Committee for radiation protection - INACRP (appointed by the Minister of the Environment and the Minister of Health) recommended, in 1993, to rectify this lack and proposed that the above two ministers issue guidelines for protecting the public and the worker from hazards of radon and radon daughters. The proposed guidelines are based on recent 1993 recommendations of the ICRP related to Radon at Home and at Work.The guidelines establish activity concentration levels, in homes and at work premises, above which remedial actions are recommended, and specify a time-table for these actions, depending on the extent to which the activity concentrations in the building exceed the remedial action levels specified. (authors)

  18. Lowering the UK domestic radon action level to reduce radiation-induced lung cancer in general population: when and where is it cost effective?

    International Nuclear Information System (INIS)

    Denman, A.R.; Phillips, P.S.

    2008-01-01

    Case studies have shown that radon gas can be present within domestic properties at sufficiently high levels that it can significantly increase the risk of lung cancer in occupants. Recently, Darby et al. (2006) have shown that this risk exists at radon concentrations as low as 100 Bq·m -3 , which is below the UK domestic Action Level of 200 Bq·m -3 . As a result, there have been suggestions that national domestic Action Levels should be reduced. This paper considers the benefits and costs of the domestic radon remediation programmes in the UK, when a range of Action Levels from 125 Bq·m -3 to 600 Bq·m -3 are applied. The variations of total cost, cost-effectiveness, dose reduction and lung cancers saved for each proposed action level, and the proportion of houses over the proposed action level, were estimated. The study shows that, for an Action Level above 200 Bq·m -3 , a completed domestic radon remediation programme in Northamptonshire, where 6.3% of existing houses have initial radon levels over 200 Bq·m -3 , will cost less and will target those most at risk, but will be less cost effective. In addition, a higher Action Level leaves a higher residual dose and greater risk of cancer in the population living in unremediated homes. Reducing the Action Level below 200 Bq·m -3 will prevent more cancers, but at significantly higher cost. It will be less cost-effective, because a significant number of houses with moderate radon levels will be remediated with modest health benefit to occupants. The study suggests that a completed radon remediation programme is most cost-effective with an action level of around 250 to 300 Bq·m -3 . The finding appears to be independent of the percentage of houses over the Action Level. This has clear implications for future health policy. (author)

  19. Interim radon-resistant construction guidelines for use in Florida-1989. Final report, August 1987-June 1988

    International Nuclear Information System (INIS)

    Pugh, T.D.

    1990-08-01

    The report gives results of a project to investigate, analyze, and develop radon-resistant construction guidelines that are consistent with other building codes and that could be applied to Florida. A literature search resulted in information on radon remediation techniques, new construction methods, and existing radon-resistant building codes such as those in Sweden and Canada. The identified techniques were amended, modified, or supplemented for incorporation into draft model guidelines for new construction in format consistent with the Southern Building Code Congress International, Inc.'s Standard Building Code. A technical review advisory committee formed during development of the guidelines, provided input and recommended changes to the draft guidelines. Although the project has resulted in guidelines for recommended construction practices, they should be coupled with a carefully planned and implemented program of experimentation. Eventually, this approach will lead to building code provisions that are scientifically defensible, cost effective, reliable, and easily incorporated into standard construction practice

  20. Method for the determination of the radon entry rate inside buildings; Methodik zur Bestimmung der Radonquellstaerke in Gebaeuden

    Energy Technology Data Exchange (ETDEWEB)

    Neugebauer, T.; Hingmann, H.; Buermeyer, J.; Grimm, V.; Spruck, K.; Breckow, J. [Technische Hochschule Mittelhessen (THM), Giessen (Germany). Inst. fuer Medizinische Physik und Strahlenschutz (IMPS)

    2016-07-01

    The radon entry rate describes the radon characteristics of a building, which are defined by its constructional condition (tightness of building envelope) and the geological realities (radon soil gas concentration). All possible radon sources of a building are considered. The determination of the radon entry rate is based on the measurement of the radon concentration inside a building and the determination of the air change rate. The air change rate can be calculated via several approaches, VDI 4300-7 provides the most common methods. The main approaches are based on the use of a tracer gas, which concentration is measured over the time. In a first attempt, a one-time and punctual injection of a tracer gas was used. A disadvantage was that the air change rate could be determined only for short periods. In the follow-up, the constant injection of a tracer gas at multiple spots was executed. With this method, it is possible to calculate the air change rate over several weeks on a continuous base; the data can be used to determine the radon entry rate. Based on those series of measurements a first analysis of possible dependencies of the radon entry rate was performed.

  1. An assessment of ecological and case-control methods for estimating lung cancer risk due to indoor radon

    International Nuclear Information System (INIS)

    Stidley, C.A.; Samet, J.M.

    1992-01-01

    Studies of underground miners indicate that indoor radon is an important cause of lung cancer. This finding has raised concern that exposure to radon also causes lung cancer in the general population. Epidemiological studies, including both case-control and ecological approaches, have directly addressed the risks of indoor residential radon; many more case-control studies are in progress. Ecological studies that associate lung-cancer rates with typical indoor radon levels in various geographic areas have not consistently shown positive associations. The results of purportedly negative ecological studies have been used as a basis for questioning the hazards of indoor radon exposure. Because of potentially serious methodologic flaws for testing hypotheses, we examined the ecological method as a tool for assessing lung-cancer risk from indoor radon exposure. We developed a simulation approach that utilizes the Environmental Protection Agency (EPA) radon survey data to assign exposures to individuals within counties. Using the computer-generated data, we compared risk estimates obtained by ecological regression methods with those obtained from other regression methods and with the open-quotes trueclose quotes risks used to generate the data. For many of these simulations, the ecological models, while fitting the summary data well, gave risk estimates that differed considerably from the true risks. For some models, the risk estimates were negatively correlated with exposure, although the assumed relationship was positive. Attempts to improve the ecological models by adding smoking variables, including interaction terms, did not always improve the estimates of risk, which are easily affected by model misspecification. Because exposure situations used in the simulations are realistic, our results show that ecological methods may not accurately estimate the lung-cancer risk associated with indoor radon exposure

  2. Development and testing of the detector for monitoring radon double-filter method

    International Nuclear Information System (INIS)

    Sevcik, P.

    2008-01-01

    Applications of physics in the study of radon transport processes in the atmosphere and of testing of atmospheric transport models require sensitive detection devices with low maintenance requirements. The most precise devices involved in the worldwide monitoring program of the atmosphere (GAW) determine volume activity of radon from a variety of daughter products of 222 Rn, resulting in a working volume of the detector (double-filter method). The purpose of this work was to explore theoretically and experimentally the possibilities and limits of a particular simple implementation of this procedure. Tested apparatus consists of a 200 dm 3 chamber (metal drum), where are developed transformation products of radon and semiconductor detector with surface barrier, which registers α particles from the conversion of daughter products 222 Rn collected on a filter at the outlet of the chamber. Testing of the apparatus takes place in the atmosphere with higher concentrations of radon. The measured variations of volume activities 222 Rn have the same character as the variations of radon concentration in the air in laboratory. Minimum detectable activity at 95% significance level is 16.0 Bq.m -3 at a pumping speed of the air 20 dm 3 .min - 1 and 13.0 Bq.m -3 at a pumping rate 24 dm 3 .min -1 . These values are still too high for using the apparatus for measuring in external atmosphere. The main limit of the apparatus is a capture of transformation products arising on the inner walls of the chamber (plate-out effect). The effectiveness of collecting 218 Po from the chamber on the filter in our measurements was only 2.8%. But we managed to increase it to about 20% by adding aerosol delivery systems into production chamber of transformation products of radon. It turns out that based on this principle can be made sensitive and continuously working monitor of radon. (author)

  3. Radon exhalation rates corrected for leakage and back diffusion – Evaluation of radon chambers and radon sources with application to ceramic tile

    Directory of Open Access Journals (Sweden)

    M. Abo-Elmagd

    2014-10-01

    Full Text Available The natural radon decay, leakage and back diffusion are the main removal processes of radon from its container. Ignoring these processes leads to underestimate the measured value of radon related parameters like exhalation rate and radium content. This work is aimed to evaluate two different radon chambers through determining their leakage rate λv and evaluation of radon source by determine its back diffusion rate λb inside the evaluated radon chambers as well as a small sealed cup. Two different methods are adapted for measuring both the leakage rate and the back diffusion rate. The leakage rate can be determined from the initial slope of the radon decay curve or from the exponential fitting of the whole decay curve. This can be achieved if a continuous monitoring of radon concentration inside the chamber is available. Also, the back diffusion rate is measured by sealing the radon source in the chamber and used the initial slope of the buildup curve to determine λb and therefore the exhalation rate of the source. This method was compared with simple equation for λb based on the ratio of the source to the chamber volume. The obtained results are applied to ceramic tile as an important radon source in homes. The measurement is targeted the ceramic glaze before and after firing as well as the obtained tile after adhere the glaze on the tile main body. Also, six different tile brands from Egyptian market are subjected to the study for comparison.

  4. Result of the intercomparison exercise on radon measuring instruments and radon detectors 'bev- radon ring 2005'

    International Nuclear Information System (INIS)

    Baumgartner, A.; Maringer, F.J.; Michai, P.; Kreuziger, M.

    2006-01-01

    In spring 2005 the Federal Office of Metrology and Surveying (B.E.V.) invited all in Austria working radon measuring institutes to an intercomparison exercise at the radon calibration laboratory in the Arsenal. The aim of this intercomparison was on the one hand an objective inquiry and documentation of the current metrological potential on the section of radon measurement in Austria - both quantitative and qualitative- and on the other hand an initiative for the participating laboratories to optimize and improve their applied calibration-, measurement and analyse technique. Ten contacted Austrian radon laboratories were prepared to participate on the radon intercomparison exercise. The intercomparison exercise was carried out from 14. till 29. June at the radon calibration laboratory in the Arsenal of the B.E.V.. As radon emanation source a five stepped arranged, at the Arsenal built radon source was used. The source ( A.D.O.T.T.O. 1 is filled with a certified Ra- 226-standard solution of the Czech Metrological Institute (C.M.I.), Prag. A simple statistic based model was used for the evaluation and assessment of the results from the participants, which consider the statistic nature of the radioactive decay combined uncertainty. Altogether 183 measuring instruments participated the intercomparison exercise. Two reference measuring instruments, 22 active and 159 passive measuring instruments. The active measuring instruments formed 6 types of instruments and as passive radon detectors were 7 different types used from the participants. The positioning of the radon measuring instruments and detectors in the radon calibration laboratory was executed in regard to statistic points of view. From the active measuring instruments 17 could qualify and from the passive methods six from eight participants were in compliance to the given criteria. Radon measurements, which could have financial and economics relating implications (e.g. architectural redevelopment or

  5. Do the UK workplace Radon Action Levels reflect the radiation dose received by the occupants?

    International Nuclear Information System (INIS)

    Denman, A.R.; Parkinson, S.; Barker, S.P.; Marley, F.; Phillips, P.S.

    1999-01-01

    In the UK, Action Levels for radon have been established at 400 Bq m -3 for the workplace and 200 Bq m -3 for the home. We have estimated the dose received by occupants of rooms with radon levels near or above the Action Level, using hourly radon readings, and a questionnaire to record occupancy. In the workplace, results for 73 staff suggest that doses are lower than expected, partly due to part-time working and partly due to the mobility of staff. The 75% quantile for the series, corrected to a 37 hour week, is 5.2 mSv at 400 Bq m -3 . Compared to the current annual limit for radiation workers, the Action Level could be increased, but the current Action Level is compatible with the recent EEC Directive requiring a lower dose limit. However, when raised radon levels in the workplace were reduced by remediation in the series we studied, the dose reduction to staff was consistently around half of the radon level reduction. Although it would be appropriate to study more locations, this suggests an Action Level for remediated workplaces of 200 Bq m -3 . Finally, in a limited series of dose assessments in domestic properties, we found that doses could considerably exceed 5 mSv at the 200 Bq m -3 Action Level, primarily because the sample included an example of high occupancy, in our case several Asian wives in purdah, whose occupancy was almost total. (author)

  6. Radon depth migration

    International Nuclear Information System (INIS)

    Hildebrand, S.T.; Carroll, R.J.

    1993-01-01

    A depth migration method is presented that used Radon-transformed common-source seismograms as input. It is shown that the Radon depth migration method can be extended to spatially varying velocity depth models by using asymptotic ray theory (ART) to construct wavefield continuation operators. These operators downward continue an incident receiver-array plane wave and an assumed point-source wavefield into the subsurface. The migration velocity model is constrain to have longer characteristic wavelengths than the dominant source wavelength such that the ART approximations for the continuation operators are valid. This method is used successfully to migrate two synthetic data examples: (1) a point diffractor, and (2) a dipping layer and syncline interface model. It is shown that the Radon migration method has a computational advantage over the standard Kirchhoff migration method in that fewer rays are computed in a main memory implementation

  7. EML indoor radon workshop, 1982

    International Nuclear Information System (INIS)

    George, A.C.; Lowder, W.; Fisenne, I.; Knutson, E.O.; Hinchliffe, L.

    1983-07-01

    A workshop on indoor radon, held at the Environmental Measurements Laboratory (EML) on November 30 and December 1, 1982, covered recent developments in radon daughter research and development. Thirty papers were presented dealing with standardization and quality assurance measurement methods, surveys, measurements strategy, physical mechanisms of radon and radon daughter transport and development of guidance standards for indoor exposures. The workshop concluded with a planning session that identified the following needs: (1) national and international intercomparisons of techniques for measuring radon and radon daughter concentrations, working level and radon exhalation flux density; (2) development and refinement of practical measurement techniques for thoron and its daughter products; (3) quantitative definition of the sources of indoor radon and the mechanisms of transport into structures; (4) better knowledge of the physical properties of radon daughters; (5) more complete and accurate data on the population exposure to radon, which can only be met by broadly based surveys; and (6) more international cooperation and information exchange among countries with major research programs

  8. Evaluation of strategies for promoting effective radon mitigation. Risk communication and economic research series. Final report

    International Nuclear Information System (INIS)

    Doyle, J.K.; McClelland, G.H.; Schulze, W.D.; Locke, P.A.; Elliott, S.R.

    1990-03-01

    The Environmental Protection Agency has estimated that as many as 20,000 lung cancer deaths per year in the United States can be attributed to exposure to radon gas. The report evaluates alternative strategies for motivating people to test for radon gas in their homes and to mitigate if necessary. Specifically, two separate radon information and awareness programs were evaluated, one targeted to the general population in the Washington, D.C. area and the other to home buyers in the Boulder, Colorado area. The results suggest that a home buyer program is likely to be far more effective in terms of effective remediation to reduce home radon levels than a program aimed at the general population. The report discusses the empirical findings and develops a recommendation for increasing the effectiveness of radon awareness and mitigation programs

  9. Method for determination of radon-222 in water by liquid scintillation counting

    International Nuclear Information System (INIS)

    Suomela, J.

    1993-06-01

    The procedure for the determination of radon-222 by liquid scintillation counting is quite specific for this radionuclide. Radon-222 is extracted readily from the water sample by an organic scintillant. The decay products of radon-222 will remain in the water phase whilst radon-222 will be extracted into the organic phase. Before measurement the sample is stored for three hours until equilibrium is reached between radon-222 and its alpha emitting decay products. The alpha activity from radon-222 and its decay products is measured in a liquid scintillation counter

  10. Mitigation of houses with extremely high indoor radon concentrations

    International Nuclear Information System (INIS)

    Jiranek, M.; Neznal, M.

    2006-01-01

    Full text of publication follows: The paper reports on the experience of the Czech Technical University in dealing with mitigation of houses in which unusually high indoor radon concentrations were found. The whole process of remediation is illustrated by example of an old single-family house that was built in the area formed by highly permeable soils with high radon content in the soil air. T he house has a small cellar located under 1/5 of the ground floor area. Two types of floors, i.e. timber floors and cracked concrete slabs were found in the house. As a result of extremely high radon concentration in the sub-floor region (up to 600 kBq/m 3 ) and leaky structures in contact with soil, radon concentrations around 100 kBq/m 3 in the cellar and up to 60 kBq/m 3 in the living rooms on the ground floor were measured prior to mitigation. Mitigation measures that were carried out in the house consist of reconstruction of timber floors and installation of active soil depressurization. Timber floors were replaced with concrete slab fitted with damp proof membrane, thermal insulation and floor covering. The soil depressurization system was made up of two sections. The first section is composed of the network of perforated pipes inserted in the drainage layer placed under the new floors and four perforated tubes drilled under the existing floors. The soil air from this section is extracted by means of a roof fan installed at the top of the vertical exhaust pipe running inside the living space and terminating above the roof. The second section was designed to withdraw by means of a small fan radon-laden air from the filling in the floor above the cellar and from perforated tubes drilled into the sub-floor region under the rooms adjacent to the cellar. It serves also for the active ventilation of the cellar. Pressure, temperature and radon concentration sensors were installed into the drainage layer during the reconstruction of floors to record variations in these

  11. Intercomparison of active and passive instruments for radon and radon progeny in North America

    International Nuclear Information System (INIS)

    George, A.C.; Tu, Keng-Wu; Knutson, E.O.

    1995-02-01

    An intercomparison exercise for radon and radon progeny instruments and methods was held at the Environmental Measurements Laboratory (EML) from April 22--May 2, 1994. The exercise was conducted in the new EML radon test and calibration facility in which conditions of exposure are very well controlled. The detection systems of the intercompared instruments consisted of. (1) pulse ionization chambers, (2) electret ionization chambers, (3) scintillation detectors, (4) alpha particle spectrometers with silicon diodes, surface barrier or diffused junction detectors, (5) registration of nuclear tracks in solid-state materials, and (6) activated carbon collectors counted by gamma-ray spectrometry or by alpha- and beta-liquid scintillation counting. 23 private firms, government laboratories and universities participated with a 165 passive integrating devices consisting of: Activated carbon collectors, nuclear alpha track detectors and electret ionization chambers, and 11 active and passive continuous radon monitors. Five portable integrating and continuous instruments were intercompared for radon progeny. Forty grab samples for radon progeny were taken by five groups that participated in person to test and evaluate their primary instruments and methods that measure individual radon progeny and the potential alpha energy concentration (PAEC) in indoor air. Results indicate that more than 80% of the measurements for radon performed with a variety of instruments, are within ±10% of actual value. The majority of the instruments that measure individual radon progeny and the PAEC gave results that are in good agreement with the EML reference value. Radon progeny measurements made with continuous and integrating instruments are satisfactory with room for improvement

  12. Programmatic Environmental Report for remedial actions at UMTRA [Uranium Mill Tailings Remedial Action] Project vicinity properties

    International Nuclear Information System (INIS)

    1985-03-01

    This Environmental Report (ER) examines the environmental consequences of implementing a remedial action that would remove radioactive uranium mill tailings and associated contaminated materials from 394 vicinity properties near 14 inactive uranium processing sites included in the Uranium Mill Tailings Remedial Action (UMTRA) Project pursuant to Public Law 95--604, the Uranium Mill Tailings Radiation Control Act (UMTRCA) of 1978. Vicinity properties are those properties in the vicinity of the UMTRA Project inactive mill sites, either public or private, that are believed to be contaminated by residual radioactive material originating from one of the 14 inactive uranium processing sites, and which have been designated under Section 102(a)(1) of UMTRCA. The principal hazard associated with the contaminated properties results from the production of radon, a radioactive decay product of the radium contained in the tailings. Radon, a radioactive gas, can diffuse through the contaminated material and be released into the atmosphere where it and its radioactive decay products may be inhaled by humans. A second radiation exposure pathway results from the emission of gamma radiation from uranium decay products contained in the tailings. Gamma radiation emitted from contaminated material delivers an external exposure to the whole body. If the concentration of radon and its decay products is high enough and the exposure time long enough, or if the exposure to direct gamma radiation is long enough, cancers (i.e., excess health effects) may develop in persons living and working at the vicinity properties. 3 refs., 7 tabs

  13. Modeling the potential impacts of different radon policies for the U.S. housing stock

    International Nuclear Information System (INIS)

    Peterson, M.D.; Ritchie, I.M.

    1995-01-01

    According to the Environmental Protection Agency (EPA) and other public health agencies in the United States, radon may be the leading cause (along with passive smoking) of lung cancer deaths among nonsmokers. Radon is estimated to be the second leading cause of lung cancer death in smokers behind smoking-related lung cancer. EPA estimates that 7,000 to 30,000 lung cancer deaths each year are due to radon exposure. (It is implied that radon-related lung cancer deaths can be prevented by reducing radon levels below EPA's guideline levels). Current EPA radon policy is based on a strategy of education, the transfer of testing and remediation technologies to the public and private sectors, and recently proposed radon-resistant construction standards for new homes. This paper models the effectiveness of current proposed, and alternative policies for reducing radon risks in U.S. residential construction. The results of our analysis suggest that EPS's projections of 2,200 'lives saved annually' as a result of its current action level of 4 pCi/l will not be achieved with its current policy in the near future. Overall, the response of radon-related mortality to most policy options is delayed and flat due in part to the large number of houses with low radon levels and the long latency period between radon exposure and the development of cancer. The modeling results suggest that more aggressive smoking reduction programs may yield greater benefits in overall lung cancer mortality (but not reduced radon exposure) than most radon-related policies. (au)

  14. Commercial mitigation techniques used in remediating a 2200 pCi/L public building

    International Nuclear Information System (INIS)

    Davidson, J.G.

    1990-01-01

    This paper reports on commercial mitigation techniques used in remediating a 2200 pCi/L public building. In March of 1989 EPA and Pa. DER officials were amazed to discover a school in Pennsylvania with levels in its library of 2200 pCi/L. The library was a 30 year old, three story slab-on-grade structure more like a commercial building than a typical school structure. It had three separate and complex HVAC systems. Initial diagnostics indicated radon levels under the slab at over 80,000 pCi/L. Further investigations revealed major entry routes and a HVAC system terribly out of balance. Remediation consisted of installing a complex sub-slab depressurization system with an exterior commercial fan unit, major entry route sealing, and working closely with a mechanical contractor to bring the HVAC systems back into balance. Initial post remediation testing showed a 99% drop in radon levels. Refinements to the system are still in progress

  15. Application of CR-39 to radon measurement

    International Nuclear Information System (INIS)

    Miyake, Hiroshi

    1988-01-01

    CR-39, an ally diglycol carbonate, has recently come into wider use as material for solid-state track detector. Etching with NaOH or KOH solution allow CR-39 to develop extremely clear etch pits attributed to alpha rays. The most widely used method for measuring radon concentration employs a plastic cup with a solid-state track detector mounted at its bottom to detect alpha rays resulting from radon or its daughters that disintegrate within or on the wall of the cup. Simple in mechanism and low in cost, this method is suitable for such a case where the radon concentration distribution over a wide area has to be measured by using a large number of devices. The concentration of radon alone can be measured with the aid of a filter attached to the mouth of the cup to remove the daughters of radon and thoron. The simplest and most effective way of improving the sensitivity of a solid-state track detector for radon concentration measurement is to electrostatically collect daughters resulting from decay of radon onto the surface of the detector. Another method widely used to determine the radon concentration is to measure the concentration of the radon daughters instead of direct measurement of the concentration of radon itself. (Nogami, K.)

  16. Asphalt emulsion radon barrier systems for uranium mill tailings: an overview of the technology

    International Nuclear Information System (INIS)

    Baker, E.G.; Hartley, J.N.; Freeman, H.D.; Gates, T.E.; Nelson, D.A.; Dunning, R.L.

    1984-03-01

    Pacific Northwest Laboratory (PNL), under contract to the US Department of Energy (DOE) Uranium Mill Tailings Remedial Action Project (UMTRAP) office, has developed an asphalt emulsion cover system to reduce the release of radon from uranium mill tailings. The system has been field tested at Grand Junction, Colorado. Results from laboratory and field tests indicate that this system is effective in reducing radon release to near-background levels ( -2 s -1 ) and has the properties required for long-term effectiveness and stability. Engineering specifications have been developed, and analysis indicates that asphalt emulsion covers are cost-competitive with other cover systems. This report summarizes the technology for asphalt emulsion radon barrier systems. 59 references, 45 figures, 36 tables

  17. Geographical distribution of the annual mean radon concentrations in primary schools of Southern Serbia – application of geostatistical methods

    International Nuclear Information System (INIS)

    Bossew, P.; Žunić, Z.S.; Stojanovska, Z.; Tollefsen, T.; Carpentieri, C.; Veselinović, N.; Komatina, S.; Vaupotič, J.; Simović, R.D.; Antignani, S.; Bochicchio, F.

    2014-01-01

    Between 2008 and 2011 a survey of radon ( 222 Rn) was performed in schools of several districts of Southern Serbia. Some results have been published previously (Žunić et al., 2010; Carpentieri et al., 2011; Žunić et al., 2013). This article concentrates on the geographical distribution of the measured Rn concentrations. Applying geostatistical methods we generate “school radon maps” of expected concentrations and of estimated probabilities that a concentration threshold is exceeded. The resulting maps show a clearly structured spatial pattern which appears related to the geological background. In particular in areas with vulcanite and granitoid rocks, elevated radon (Rn) concentrations can be expected. The “school radon map” can therefore be considered as proxy to a map of the geogenic radon potential, and allows identification of radon-prone areas, i.e. areas in which higher Rn radon concentrations can be expected for natural reasons. It must be stressed that the “radon hazard”, or potential risk, estimated this way, has to be distinguished from the actual radon risk, which is a function of exposure. This in turn may require (depending on the target variable which is supposed to measure risk) considering demographic and sociological reality, i.e. population density, distribution of building styles and living habits. -- Highlights: • A map of Rn concentrations in primary schools of Southern Serbia. • Application of geostatistical methods. • Correlation with geology found. • Can serve as proxy to identify radon prone areas

  18. Radon in dwellings in selected areas of Ireland

    International Nuclear Information System (INIS)

    Madden, J.S.; Duffy, J.T.; Mackin, G.A.; Colgan, P.A.; McGarry, A.T.

    1994-10-01

    This report presents and interprets the results of surveys of domestic radon concentrations carried out by the Radiological Protection Institute of Ireland between 1989 and 1992. Data from low-density monitoring surveys in counties Mayo, Galway (including the Aran Island of Inis Mor) and Clare and in north Kerry, in addition to more detailed surveys in Moycullen and Salthill in Co. Galway and south Cork city are presented. The highest seasonally-corrected radon level found in any of the 1755 dwellings surveyed was 2399 Bq/m 3 . This is twelve times the national Reference Level of 200 Bq/m 3 , and corresponds to an annual radiation dose to occupants of the house of 60 mSv, three times the maximum dose which radiation workers are allowed to receive under internationally-accepted standards. Statistical evaluation of the data has allowed classification of 10 km grid square areas on the basis of the predicted proportion of houses in each grid square with radon levels in excess of the national Reference Level, 200 Bq/m 3 . The most affected areas occur in counties Mayo and Galway, and to a lesser extent in south-east Cork city. In county Galway six grid squares are predicted to have more than 20% of houses with radon concentrations in excess of 200 Bq/m 3 . In the most affected grid square 30% of houses are predicted to have radon concentrations in excess of this level. It is important that householders in these areas be strongly encouraged to have the radon levels in their houses measured in order to identify the individual houses in which remedial measures are required. The risk associated with longterm exposure to radon has been calculated using the latest risk factor recommended by the International Commission on Radiological Protection. For average residents exposed to indoor radon concentrations of 200 Bq/m 3 the estimated lifetime risk of premature death from lung cancer, due to radon, is about 2%. This risk is a significant addition to the prevailing lifetime

  19. Quantitative evaluation of the lung cancer deaths attributable to residential radon: A simple method and results for all the 21 Italian Regions

    International Nuclear Information System (INIS)

    Bochicchio, F.; Antignani, S.; Venoso, G.; Forastiere, F.

    2013-01-01

    Pooled analyses of epidemiological case-control studies on lung cancer and residential radon have shown that radon exposure in dwellings increases lung cancer risk, and that the increase is statistically significant also for prolonged exposures to low-medium level of radon concentration, i.e. levels commonly found in many dwellings. In this paper, a simple method to evaluate the health burden due to the presence of radon in homes (i.e. the number of lung cancer deaths attributable to radon exposure in dwellings) was presented. This method is based on the following parameters: i) the excess relative risk per unit of exposure evaluated in case-control studies; ii) the average radon concentration that can be considered representative of population exposure in dwellings; iii) the total number of lung cancer deaths occurring each year. Moreover, the interaction between radon and cigarette smoking is needed to be taken into account: in fact, although most of the persons are non-smokers, most of the lung cancer deaths attributed to radon are actually due to the multiplicative effect of radon and cigarette smoking. To show this effect, the number of radon related lung cancer deaths estimated to occur among current, former and never smokers was calculated separately for males and females, taking into account the relative risk of lung cancer for the different smoking categories and the prevalence of smoking habits. The methodology described in this work was applied to all the 21 Italian Regions in order to illustrate it. The overall fraction of lung cancer deaths attributable to radon in Italy is about 10%, with values in individual Regions ranging from 4% to 16%. The greater part of the lung cancers attributable to radon is estimated to occur among current smokers for both males and females (72% and 60%, respectively, at national level). This is due to the synergistic effects of radon and cigarette smoking, which should therefore be taken into account in policies aimed to

  20. Result of the intercomparison exercise on radon measuring instruments and radon detectors 'bev- radon ring 2005'

    Energy Technology Data Exchange (ETDEWEB)

    Baumgartner, A. [Vienna Univ. of Technology, Atominstitut, Wien (Austria); Maringer, F.J.; Michai, P.; Kreuziger, M. [BEV-Federal Office of Metrology and Surveying, Wien (Austria)

    2006-07-01

    In spring 2005 the Federal Office of Metrology and Surveying (B.E.V.) invited all in Austria working radon measuring institutes to an intercomparison exercise at the radon calibration laboratory in the Arsenal. The aim of this intercomparison was on the one hand an objective inquiry and documentation of the current metrological potential on the section of radon measurement in Austria - both quantitative and qualitative- and on the other hand an initiative for the participating laboratories to optimize and improve their applied calibration-, measurement and analyse technique. Ten contacted Austrian radon laboratories were prepared to participate on the radon intercomparison exercise. The intercomparison exercise was carried out from 14. till 29. June at the radon calibration laboratory in the Arsenal of the B.E.V.. As radon emanation source a five stepped arranged, at the Arsenal built radon source was used. The source ( A.D.O.T.T.O. 1 is filled with a certified Ra- 226-standard solution of the Czech Metrological Institute (C.M.I.), Prag. A simple statistic based model was used for the evaluation and assessment of the results from the participants, which consider the statistic nature of the radioactive decay combined uncertainty. Altogether 183 measuring instruments participated the intercomparison exercise. Two reference measuring instruments, 22 active and 159 passive measuring instruments. The active measuring instruments formed 6 types of instruments and as passive radon detectors were 7 different types used from the participants. The positioning of the radon measuring instruments and detectors in the radon calibration laboratory was executed in regard to statistic points of view. From the active measuring instruments 17 could qualify and from the passive methods six from eight participants were in compliance to the given criteria. Radon measurements, which could have financial and economics relating implications (e.g. architectural redevelopment or

  1. Comparative Measurements of Radon Concentration in Soil Using Passive and Active Methods in High Level Natural Radiation Area (HLNRA of Ramsar

    Directory of Open Access Journals (Sweden)

    Amanat B

    2013-12-01

    Full Text Available Background: Radon and its daughters are amongst the most important sources of natural exposure in the world. Soil is one of the signifcant sources of radon/thoron due to both radium and thorium so that the emanated thoron from it may cause in creased uncertainties in radon measurements. Recently, a diffusion chamber has been designed and optimized for passive discriminative measurements of radon/thoron concentrations in soil. Objective: In order to evaluate the capability of the passive method, some com parative measurements (with active methods have been performed. Method: The method is based upon measurements by a diffusion chamber, includ ing two Lexan polycarbonate SSNTDs, which can discriminate the emanated radon/ thorn from the soil by delay method. The comparative measurements have been done in ten selected points of HLNRA of Ramsar in Iran. The linear regression and cor relation between the results of two methods have been studied. Results: The results show that the radon concentrations are within the range of 12.1 to 165 kBq/m3 values. The correlation between the results of active and passive methods was measured by 0.99 value. As well, the thoron concentrations have been measured between 1.9 to 29.5 kBq/m3 values at the points. Conclusion: The sensitivity as well as the strong correlation with active mea surements shows that the new low-cost passive method is appropriate for accurate seasonal measurements of radon and thoron concentration in soil.

  2. Environmental remediation activities at the Ningyo-toge Uranium Mine, Japan

    International Nuclear Information System (INIS)

    Saito, Hiroshi; Taki, Tomohiro

    2011-01-01

    Ningyo-toge Uranium Mine is subject to the environmental remediation. The main purposes are to take measures to ensure the radiation protection from the exposure pathways to humans in future, and to prevent the occurrence of mining pollution. The Mill Tailings Pond in the Ningyo-toge Uranium Mine has deposited mining waste and impounded water as a buffer reservoir before it is transferred to the Water Treatment Facility. It is located at the upstream of the water-source river, and therefore, for the environmental remediation, the highest priority has been put to it among many facilities in the Mine. So far, basic concept has been examined and planning has been carried out for the remediation. Also, a great number of data has been acquired, and using the data, some remediation activities have already begun, including designing for the upstream part of the Mill Tailings Pond. According to the current plan, the Mill Tailings Pond will be covered by capping following dewatering and compressing of mill tailings. The capping is composed of 'radon barrier' for lowering radon-gas dissipation and dose rate, and its protection layer. Natural materials are planned to be used for the capping to alleviate the future maintenance. After capping, data will be accumulated to verify the effectiveness of the capping, and if proved effective, it will be utilized for the capping of the downstream part. (author)

  3. Radon as a hydrological indicator

    Energy Technology Data Exchange (ETDEWEB)

    Komae, Takami [National Research Inst. of Agricultural Engineering, Tsukuba, Ibaraki (Japan)

    1997-02-01

    The radon concentration in water is measured by a liquid scintillation method. After the radioactive equilibrium between radon and the daughter nuclides was attained, the radon concentration was determined by the liquid scintillation analyzer. {alpha}-ray from radon, then two {beta}- and two {alpha}-ray from the daughter nuclei group were released, so that 500% of the apparent counting efficiency was obtained. The detector limit is about 0.03 Bq/l, the low value, which corresponds to about 5.4x10{sup -15} ppm. By determining the radon concentration in groundwater, behavior of radon in hydrological process, the groundwater exchange caused by pumping and exchange between river water and groundwater were investigated. The water circulation analysis by means of radon indicator in the environment was shown. By using the large difference of radon concentration between in river water and in groundwater, arrival of injected water to the sampling point of groundwater was detected. (S.Y.)

  4. A study of radon variation in dwelling during 1988

    International Nuclear Information System (INIS)

    Shaikh, A.N.; Ramachandran, T.V.; Muraleedharan, T.S.; Subbaramu, M.C.

    1989-01-01

    Natural radioactivity due to radon and its progeny levels indoors contributes significantly to the total radiation to man. The main source of radon and its progeny in a dwelling is the emanation of radon gas from soil. The temperature and ventilation vary in a dwelling during the year. These parameters influence the indoor radon levels. The seasonal variation of radon was studied in a dwelling as well as in the outside air. The filter paper method and alpha counting, and the solid state track detector technique and track counting were used to study the radon levels. The geometric mean of radon daughters concentrations were 0.5 mWL and 0.8 mWL measured by filter-paper method and SSNTD method respectively. The geometric mean of radon concentrations were 6.2 Bqm -3 and 10.0 Bqm -3 by filter-paper method and SSNTD method respectively. (author). 3 figs., 3 tabs., 13 refs

  5. Removing method for radon gas exhausted from nuclear fuel material

    International Nuclear Information System (INIS)

    Kato, Kenji.

    1993-01-01

    A centrifugal separator is disposed in the midway of an exhaustion pipe of a nuclear fuel handling facility, and exhausted gases are sent into a rotational cylinder of the separator. Radon gases in the midway of exhaustion are separated from the exhaustion gases by the centrifugal force of the separator and caused to stagnate at the periphery of the circumferential wall of the rotational cylinder. At the same time, the exhaustion gases having the radon gases separated therefrom are exhausted from the periphery of a rotational shaft of the rotational cylinder. Then, the radon gases stagnated in the rotational cylinder are decayed depending on the half-decay time. With such procedures, the radon gases can be removed continuously without discharging them to the outside. Further, it is preferred that an exhaustion blower or the like for putting the inside of the nuclear fuel handing facility to a negative pressure is disposed as in a conventional case. Further, a plurality of centrifugal separators may be disposed to exhaustion pipes, to remove radon gases in the exhaust gases by a multi stage way. Radon gases can be removed in a saved space with no requirement for exchange of adsorbents or temperature control. (T.M.)

  6. Radon-Instrumentation

    International Nuclear Information System (INIS)

    Moreno y Moreno, A.

    2003-01-01

    The presentation of the active and passive methods for radon, their identification and measure, instrumentation and characteristics are the objectives of this work. Active detectors: Active Alpha Cam Continuous Air Monitor, Model 758 of Victoreen, Model CMR-510 Continuous Radon Monitor of the Signature Femto-Tech. Passive detectors: SSNTD track detectors in solids Measurement Using Charcoal Canisters, disk of activated coal deposited in a metallic box Electrets Methodology. (Author)

  7. Remedial design process for Montclair/West Orange and Glen Ridge radium sites

    International Nuclear Information System (INIS)

    MacIndoe, M.; Johnson, R.; Paez-Restrepo, A.; Wilkinson, S.; Hyman, M.

    1994-01-01

    The Montclair/West Orange and Glen Ridge Superfund Sites, located in Essex County, New Jersey, are contaminated to varying degrees with radioactive materials. The waste materials originated from radium processing facilities prevalent in the area during the early 1900's. The two sites consist of 769 residential and commercial properties having a combined land area of approximately 210 acres. Historically, radioactive waste materials were disposed as landfill material in what were once rural areas. As development flourished, homes and streets were constructed over the landfilled waste. In 1981 the EPA conducted an aerial gamma radiation survey of the area to determine the presence of radioactive materials. It was from this survey that subsequent ground studies where initiated, and elevated gamma radiation and radon levels were discovered. The paper will discuss the methods used to obtain data through field investigations; the relationship between the interpretation of data to define the vertical and lateral limits of contamination and the selection of remedial design methods used to develop excavation plans; the evolution of remediation methods and technologies relative to the remediation of structures by underpinning basements, on-grade structures, and chimneys; removal of contaminated material beneath footings without cribbing; and demolition of basement foundation walls (where contaminated) without use of traditional support methods. Finally, the paper will discuss remedial action execution of the work

  8. A calibration facility for radon fluxmeter

    International Nuclear Information System (INIS)

    Li Xianjie; Qiu Shoukang; Zhou Jianliang; Liu Chunkui; Pan Jialin; Yang Mingli

    1998-01-01

    Calibration facilities for radon fluxmeter with three kinds of different emanation medium have been developed. The stability of radon flux is 5%, 9% (RSD) respectively. The uniformity of radon flux is 4.5%, 8.5% (RSD) respectively. These specifications fulfill the calibration requirement for radon fluxmeter. The determination of radon flux of facility takes full account of eliminating the main error source-attenuation effect (including leakage and back diffusion etc.): not only prevent attenuation and make a relevant correction. Therefore the accuracy of determination is assured. The calibration, intercomparison of radon flux meter and the quantitatively evaluation on the measurement method of radon flux are made to be possible by the successful establishment of this facility. (author)

  9. Improved thomas formula for radon measurement

    International Nuclear Information System (INIS)

    Ji Changsong

    1991-06-01

    The FT 648 type portable absolute radon meter has been developed and the designing principle of this instrument is introduced. The absolute radon meter differs from relative radon meter. By using structure parameters, operating parameters and readout of this instrument, the radon content of measured gas is obtained directly without calibration in advance. Normally, the calibration is done by a standard radioactive gaseous source of which the radon concentration is known. The systematic error is removed by adding filter-efficiency Σ, α self-absorption correction β, energy spectrum correction S, geometric factor Ω of probe and gravity dropping correction factor G to the Thomas formula for radon measurement of two-filter method. The atmosphere radon content, which is given in hour-average, in Beijing area was measured by FT 648 type absolute radon meter. The measurement lasted continuously for several days and nights and a 'saddle shape' of radon content-time curve was observed. The day's average radon content was 8.5 Bq·m -3

  10. Measurements of radon and chemical elements: Popocatepetl volcano; Mediciones de radon y elementos quimicos: Volcan Popocatepetl

    Energy Technology Data Exchange (ETDEWEB)

    Pena, P.; Segovia, N.; Lopez, B.; Reyes, A.V. [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico); Armienta, M.A.; Valdes, C.; Mena, M. [IGFUNAM, Ciudad Universitaria, 04510 Mexico D.F. (Mexico); Seidel, J.L.; Monnin, M. [UMR 5569 CNRS Hydrosciences, Montpellier (France)

    2002-07-01

    The Popocatepetl volcano is a higher risk volcano located at 60 Km from Mexico City. Radon measurements on soil in two fixed seasons located in the north slope of volcano were carried out. Moreover the radon content, major chemical elements and tracks in water samples of three springs was studied. The radon of soil was determined with solid detectors of nuclear tracks (DSTN). The radon in subterranean water was evaluated through the liquid scintillation method and it was corroborated with an Alpha Guard equipment. The major chemical elements were determined with conventional chemical methods and the track elements were measured using an Icp-Ms equipment. The radon on soil levels were lower, indicating a moderate diffusion of the gas across the slope of the volcano. The radon in subterranean water shown few changes in relation with the active scene of the volcano. The major chemical elements and tracks showed a stable behavior during the sampling period. (Author)

  11. Risk management strategies for the radon paradox in radiation protection

    International Nuclear Information System (INIS)

    Poffijn, A.; Eggermont, G.X.; Van Deynse, A.

    1996-01-01

    Indoor radon is recognised as being the most important radiation burden for the general public. In Belgium, as in many other countries, exposure levels giving rise to yearly risks of more than 10 -2 have been found. This latter value is normally considered unacceptable for the public. Moreover, an important fraction of the population lives in houses with radon levels of more than 400 Bq.m -3 , representing a risk level of 10 -3 per year or more. A level of this order is the limit for authorised and regulated activities at work. Prevention and intervention opportunities exist for these situations. The dose reduction opportunities are limited, but higher than the total collective dose in all nuclear activities. The analysis of radiation protection approaches, communication and decision-making for radon, compared to nuclear industrial activities shows incoherence at different levels. As a first attempt to develop a rational and coherent approach, cost-benefit analysis was applied to radon. Four optimisation scenarios were developed: three remediation and one about prevention. Referring to the α values applied by radiation protection authorities in France, Sweden and the Netherlands, the different scenarios are found to be highly justified. (author)

  12. Intercomparison and intercalibration of passive/active radon and active radon progeny instruments and methods in North America

    International Nuclear Information System (INIS)

    George, A.C.; Tu, Keng W.

    1993-06-01

    An intercomparison and intercalibration exercise for radon and radon progeny measurements made with active and passive instruments was held at EML from October 22--30,1992. Twenty-five participants submitted 96 passive integrating devices, eight active devices for radon, and seven integrating devices for potential alpha energy concentration (PAEC). In addition, 40 grab samples for radon progeny analysis were taken by five groups that participated in person during the intercomparison. The results reported to EML indicate that the majority of the participants (70%) obtained mean results within 10% of the EML reference value. Although the instruments used in this exercise are based on different principles of collection and detection, they all appear reliable. However, in some instances there seemed to be some minor problems with quality control and calibration bias. Also, the large counting errors for the PAEC experienced by some of the participants can be minimized by using higher sampling air flow rates without sacrificing instrument portability

  13. Exhalation of radon and thoron from ground surface

    International Nuclear Information System (INIS)

    Megumi, Kazuko

    1978-01-01

    When radon and thoron in the environment are considered, the exhalations of radon and thoron from the ground surface are important. The following matters are described: a method of measuring directly the quantities of radon and thoron exhaled from the ground surface, the respective quantities measured by the method in summer and winter, and the dependence of the exhalations upon soil particle sizes. In this direct method, to obtain the exhalation quantities, radon and thoron from the ground surface are adsorbed in granular active carbon, and the γ-ray spectra are measured. The method is capable of measuring radon and thoron simultaneously in direct and inexpensive manner. For continuous measurement, however, it needs further improvement. The measurements by the method revealed the difference between summer and winter, the effect of rainfall, the dependence on soil particle size and on soil moisture of radon and thoron exhalations. (J.P.N.)

  14. Asphalt emulsion radon barrier systems for uranium mill tailings: an overview of the technology

    Energy Technology Data Exchange (ETDEWEB)

    Baker, E.G.; Hartley, J.N.; Freeman, H.D.; Gates, T.E.; Nelson, D.A.; Dunning, R.L.

    1984-03-01

    Pacific Northwest Laboratory (PNL), under contract to the US Department of Energy (DOE) Uranium Mill Tailings Remedial Action Project (UMTRAP) office, has developed an asphalt emulsion cover system to reduce the release of radon from uranium mill tailings. The system has been field tested at Grand Junction, Colorado. Results from laboratory and field tests indicate that this system is effective in reducing radon release to near-background levels (<2.5 pCi m/sup -2/s/sup -1/) and has the properties required for long-term effectiveness and stability. Engineering specifications have been developed, and analysis indicates that asphalt emulsion covers are cost-competitive with other cover systems. This report summarizes the technology for asphalt emulsion radon barrier systems. 59 references, 45 figures, 36 tables.

  15. Radon thematic days - Conference proceedings

    International Nuclear Information System (INIS)

    2011-03-01

    This document brings together the available presentations given at the Radon thematic days organized by the French society of radiation protection (SFRP). Twenty five presentations (slides) are compiled in the document and deal with: 1 - General introduction about radon (Sebastien Baechler, IRA); 2 - Survey of epidemiological studies (Dominique Laurier, IRSN); 3 - Dosimetric model (Eric Blanchardon, Estelle Davesne, IRSN); 4 - Radon issue in Franche-Comte: measurement of the domestic exposure and evaluation of the associated health impact (Francois Clinard, InVS); 5 - WHO's (World Health Organization) viewpoint in limiting radon exposure in homes (Ferid Shannoun, OMS); 6 - Radon measurement techniques (Roselyne Ameon, IRSN); 7 - Quality of radon measurements (Francois Bochud, IRA); 8 - International recommendations (Jean-Francois Lecomte, IRSN); 9 - Radon management strategy in Switzerland - 1994-2014 (Christophe Murith, OFSP); 10 - 2011-2015 action plan for radon risk management (Jean-Luc Godet, Eric Dechaux, ASN); 11 - Radon at work place in Switzerland (Lisa Pedrazzi, SUVA); 12 - Strategies of radiation protection optimization in radon exposure situations (Cynthia Reaud, CEPN); 13 - Mapping of the radon potential of geologic formations in France (Geraldine Ielsch, IRSN); 14 - Radon database in Switzerland (Martha Gruson, OFSP); 15 - Radon 222 in taps water (Jeanne Loyen, IRSN); 16 - Buildings protection methods (Bernard Collignan, CSTB, Roselyne Ameon, IRSN); 17 - Preventive and sanitation measures in Switzerland (Claudio Valsangiacomo, SUPSI); 18 - Training and support approach for building specialists (Joelle Goyette-Pernot, Fribourg engineers and architects' school); 19 - Status of radon bulk activity measurements performed between 2005-2010 in public areas (Cyril Pineau, ASN); 20 - Neuchatel Canton experiments (Didier Racine, SENE); 21 - Montbeliard region experience in the radon risk management (Isabelle Netillard, Pays de Montbeliard Agglomeration); 22

  16. Rice Husk Ash (RHA): radon remediations and other applications

    International Nuclear Information System (INIS)

    Sethi, Beena; Sharma, Jyoti; Kant, Krishan

    2013-01-01

    Rice Husk Ash has been used to obstruct the diffusion of radon through building materials and it has been reported that the substitution of 20-30% rice husk ash with cement leads to lower radon diffusion and exhalation rates with higher compressive strength as compared to control concrete. It can also be used to treat dyes. The waste water containing dyes is very difficult to treat, since the dyes are recalcitrant organic molecules, resistant to aerobic digestion, and are stable to light, heat and oxidising agents. Light is one of the components which aquatic organisms require for their development and any deficit caused by coloured effluent leads to an imbalance of the ecosystem. Because of increasingly stringent restrictions on the organic content of industrial effluents, it is necessary and important to eliminate dyes from wastewater before it is discharged. In the present work, thermodynamic study of adsorption of Amaranth dye on to steam activated pigmented carbon prepared from rice husk (Oryza sativa) was investigated. The adsorbent was investigated under variable system parameters, such as initial concentration of dye, adsorbent dose and temperature. The adsorption equilibrium studied both by Langmuir and Freundlich isotherms. Linearity of the Langmuir isotherm plots indicate the chemical nature of the interactions while the linear Freundlich isotherms point to non specific and energetically non - uniform nature of the adsorption sites. The values of Langmuir monolayer capacity (q m ) are between 0.9 and 1.0 mg/g. The results obtained indicate a potential use of SAPRHC for removing dyes like Amaranth dye from water. (author)

  17. Analysis of infiltration through a clay radon barrier at an UMTRA disposal cell

    International Nuclear Information System (INIS)

    1991-01-01

    An infiltration study was initiated in January 1988 to assess the percent saturation in, and infiltration through, clay radon barriers of typical Uranium Mill Tailings Remedial Action (UMTRA) Project disposal cells. Predicting infiltration through the radon barrier is necessary to evaluate whether the disposal cell will comply with the proposed US Environmental Protection Agency (EPA) groundwater protection standards (40 CFR 192). The groundwater standards require demonstrating that tailings seepage will not cause background concentrations or maximum concentration limits (MCLs) to be exceeded at the downgradient edge of the disposal facility (the point of compliance, or POC). This demonstration generally consists of incorporating the predicted seepage flux and the concentration of the specific hazardous constituents into a contaminant transport model, and predicting the resultant concentrations at the POC. The infiltration study consisted of a field investigation to evaluate moisture conditions in the radon barrier of the completed Shiprock, New Mexico, UMTRA Project disposal cell and previously completed UMTRA Project disposal cells at Clive, Utah, and Burrell, Pennsylvania. Coring was conducted to measure percent saturation profiles in the radon barriers at these disposal cells. In addition, a detailed investigation of the Shiprock radon barrier was conducted to establish the effects of meteorological stresses on moisture conditions in the filter layer and radon barrier. The Shiprock infiltration study was also intended to characterize hydraulic gradients and operational unsaturated hydraulic conductivities in the radon barrier

  18. Radon exposure and lung cancer

    International Nuclear Information System (INIS)

    Planinic, J.; Vukovic, B.; Faj, Z.; Radolic, V.; Suveljak, B.

    2003-01-01

    Although studies of radon exposure have established that Rn decay products are a cause of lung cancer among miners, the lung cancer risk to the general population from indoor radon remains unclear and controversial. Our epidemiological investigation of indoor radon influence on lung cancer incidence was carried out for 201 patients from the Osijek town. Ecological method was applied by using the town map with square fields of 1 km 2 and the town was divided into 24 fields. Multiple regression study for the lung cancer rate on field, average indoor radon exposure and smoking showed a positive linear double regression for the mentioned variables. Case-control study showed that patients, diseased of lung cancer, dwelt in homes with significantly higher radon concentrations, by comparison to the average indoor radon level of control sample. (author)

  19. An investigation of radon mitigation in Pennsylvania

    International Nuclear Information System (INIS)

    Belanger, W.E.

    1990-01-01

    This paper reports that Radon mitigation contractors were contacted to obtain information on the progress of radon mitigation in Pennsylvania. Information was obtained on the beginning and ending radon concentrations, the cost of the job, the mitigation method used, and the location by zip code. Most radon mitigations achieved reductions below 90 percent, and most achieved 4 pCi/1. 65 percent achieved 2 pCi/1. There was little relationship between the cost of the job and either the percent reduction or the beginning radon. Percent reduction was strongly related to beginning radon, with lower percent reductions associated with low starting radon

  20. Uranium City radiation reduction program: further studies on remedial measures and radon infiltration routes for houses with block walls

    International Nuclear Information System (INIS)

    Leung, M.K.

    1980-01-01

    This report describes the results of tests of partial sealing of concrete block walls to prevent radon infiltration into houses in Uranium City, and gives the results of studies of radon migration through concrete block walls. Results of some laboratory tests on the effectiveness of concrete blocks as a radon barrier are included

  1. Seasonal variation measurements of radon levels in caves using SSNTD method

    International Nuclear Information System (INIS)

    Espinosa, G.; Golzarri, J.I.; Gammage, R.B.; Sajo-Bohus, L.; Viccon-Pale, J.; Signoret-Poillon, M.

    2008-01-01

    The results of radon concentration measurements inside of the Gabriel caves of Mexico, during three consecutive two-month periods covering almost three seasons, are reported in the present work. The radio-ecological importance of this site is related to the radon and its concentration-dynamic behavior in the cave. Further interest in radiation safety motivated this initiative since routine biological field work is done, with people spending long periods of time there. CR-39 passive nuclear track detector was chosen for this survey. Radon concentration levels decrease during the rainy season and show different values depending on the ventilation and geometeorological structure. Measured values range between 956 and 4931Bqm -3 , an indication that radon doses may exceed the allowed values for workers. This project is part of a larger study of indoor radon alpha emitters in Mexican caves

  2. Seasonal variation measurements of radon levels in caves using SSNTD method

    Energy Technology Data Exchange (ETDEWEB)

    Espinosa, G. [Instituto de Fisica, Universidad Nacional Autonoma de Mexico, Apartado Postal 20-364, 01000 Mexico, D.F. (Mexico)], E-mail: espinosa@fisica.unam.mx; Golzarri, J.I. [Instituto de Fisica, Universidad Nacional Autonoma de Mexico, Apartado Postal 20-364, 01000 Mexico, D.F. (Mexico); Gammage, R.B. [Oak Ridge National Laboratory, PO Box 2008, Oak Ridge, TN 37831-6480 (United States); Sajo-Bohus, L. [Departamento de Fisica, Universidad Simon Bolivar (Venezuela); Viccon-Pale, J.; Signoret-Poillon, M. [El Hombre y su Ambiente, UAM-Xochimilco, Mexico D.F. (Mexico)

    2008-08-15

    The results of radon concentration measurements inside of the Gabriel caves of Mexico, during three consecutive two-month periods covering almost three seasons, are reported in the present work. The radio-ecological importance of this site is related to the radon and its concentration-dynamic behavior in the cave. Further interest in radiation safety motivated this initiative since routine biological field work is done, with people spending long periods of time there. CR-39 passive nuclear track detector was chosen for this survey. Radon concentration levels decrease during the rainy season and show different values depending on the ventilation and geometeorological structure. Measured values range between 956 and 4931Bqm{sup -3}, an indication that radon doses may exceed the allowed values for workers. This project is part of a larger study of indoor radon alpha emitters in Mexican caves.

  3. Radon reference levels and priority areas considering optimisation and avertable lung cancers

    International Nuclear Information System (INIS)

    Bochicchio, F.; Venoso, G.; Antignani, S.; Carpentieri, C.

    2017-01-01

    Protection from radon exposure in workplaces and dwellings, as included in the latest relevant international regulations and recommendations, is based on the new concept of 'reference level' whose meaning is significantly different from that of previous 'action level' concept. In fact, whereas remedial actions had to be considered only for radon concentrations above the action level, actions to optimise radon exposure are requested with priority above reference level but optimisation should be applied also for radon concentrations below reference level. Similar considerations can be applied to the usually called 'Rn-prone' areas, which are here proposed to be regulated as 'priority' areas. The main implication of these new challenging concepts is a substantial increase of avertable lung cancer deaths, as it will be shown using Italian data. Some practical examples of possible policy actions fitting an approach based on these new concepts will also be given, which could be useful for the implementation of the Council Directive 2013/59/Euratom. (authors)

  4. Comparison of two methods for investigating indoor radon daughters

    International Nuclear Information System (INIS)

    Vanmarcke, H.; Raes, F.

    1988-01-01

    The dynamics of radon daughters in realistic indoor environments has been investigated experimentally at the Universities of Gottingen and Gent. Both studies yielded the important result that the fraction of unattached radon daughters is higher than is assumed in earlier studies. Reineking-Porstendorfer and Vanmarcke-Raes adopted quite different methodologies to determine the unattached fraction. In this paper the methodologies are compared by means of joint measurements performed in a house with elevated radon concentrations. The results for the attachment rate, the deposition rate of the unattached daughters and the unattached fraction differ significantly, while the results for the deposition rate of the attached daughters and the equilibrium factor broadly agree. (author)

  5. Review of official measuring methods and official interpretations of measuring results used in the radon programme of the Czech Republic

    International Nuclear Information System (INIS)

    Thomas, J.; Hulka, J.; Fojtikova, I.

    2004-01-01

    Attention is centered on the following topics: 1. Preventive measures (Monitoring the radioactivity in building materials; Monitoring the radioactivity in drinking water; Monitoring the evaluating building sites; Evaluating finished unoccupied new buildings; Survey of occupied new buildings); 2. Measuring methods in the intervention programme (Identification of houses with elevated radon risk; Testing the effectiveness of mitigation; Searching for radon sources - radon diagnosis); 3. Metrological assurance of the Czech Radon Programme. (P.A.)

  6. Environmental analysis of radiation exposure by radon in Saxon buildings and impact of the EnEV. An old problem in a new dimension; Umweltanalyse zur Strahlenbelastung durch Radon in saechsischen Gebaeuden und Auswirkungen der EnEV. Ein altes Problem mit neuen Dimensionen

    Energy Technology Data Exchange (ETDEWEB)

    Gottwald, Jan; Schneider, Lutz [Stoller Ingenieurtechnik GmbH, Dresden (Germany); Koeter, Nico [TU Bergakademie Freiberg (Germany)

    2015-07-01

    Radon in buildings is being widely studied since the 1990s. These studies have revealed some cases of very high radiation exposure for the inhabitants of residential buildings in Saxony in particular. Even a proposed raising of the radon reference values from 100 Bq/m{sup 3} to 300 Bq/m{sup 3} (in the case of an eventually 1:1 implementation of the EU recommendations into German law), would not even slightly aid the situation in the designated areas with high radon availability, as the standards of the Energieeinsparverordnung (Energy Saving Ordinance, EnEV) can result in significant radiation exposure, if no comprehensive radon protection is implemented. Based on long-term radon measurements in Saxony from the nineties, before the introduction of the EnEV, this report will show potential outcomes and estimate the extend of suitable remediation measures.

  7. Remedial activities effectiveness verification in tailing areas

    International Nuclear Information System (INIS)

    Kluson, J.; Thinova, L.; Svoboda, T.; Neznal, M.

    2015-01-01

    The complex radiological study of the basin of sludge from the uranium ore mining and preprocessing was done. Air kerma rates (including its spectral analysis) at the reference height of 1 m above ground over the whole area were measured and radiation fields mapped during two measuring campaigns (years 2009 and 2014). K, U and Th concentrations in sludge and concentrations in depth profiles (including radon concentration and radon exhalation rates) in selected points were determined using gamma spectrometry for in situ as well as laboratory samples measurement. Results were used for the analysis, design evaluation and verification of the efficiency of the remediation measures. Efficiency of the sludge basin covering by the inert material was modelled using MicroShield code. (authors)

  8. Radiohygienic aspects of the remediation works of the former uranium mine in Hungary

    International Nuclear Information System (INIS)

    Kerekes, A.; Juhasz, L.; Fueloep, N.; Koeteles, G.J.; Csoevari, M.

    2002-01-01

    A national project was initiated to remediate the site of the Hungarian uranium mine closed in 1997. The radiation levels on the mining and milling area were in the range between the background level and up to 10 to 100 times the background level. The most important phases of the remediation work investigated to assess the radiation burden of the workers and of the population living around the area to be recultivated are: transportation of mill tailings, covering of piles of refuse ores and mill tailings by soil, dismounting of the ore processing unit. The environmental radiation protection levels for the remediation processes are the following: radon flux from the surface of the restored tailings ponds 0.7 Bq.m -2 s -1 , radon concentration increment in the open air 20 Bq.m -3 , external dose rate increment above the restored site 200 nGy.h -1 . Based on the model assessments the exposure route of external dose was identified as the main source of the radiation dose for the workers and the population as well. The main conclusions concerning the occupational and environmental radiation protection are: the remediation work should be considered as a radiation practice, the use of the restored area by the population needs limited restrictions only. (author)

  9. Radon

    Science.gov (United States)

    ... radon-resistant features. These features include gravel and plastic sheeting below the foundation, along with proper sealing ... lower the radon level. Detailed information about radon reduction in your home or building can be found ...

  10. The practical use of electrets in a public health radon remediation campaign

    International Nuclear Information System (INIS)

    Denman, A.R.; Groves-Kirkby, C.J.; Phillips, P.S.; Crockett, R.G.M.; Woolridge, A.; Gillmore, G.K.

    2005-01-01

    As part of a long-term assessment of domestic radon in Northamptonshire, England, a batch of 50 commercially available electrets was deployed for nearly 1000 exposures, individual exposure periods ranging from one to eight weeks. Responsivity was comparable with that of recently-calibrated Durridge RAD-7 continuously-monitoring equipment. Voltage history analysis indicated mean voltage decay during manufacturers' QA assessment of 0.059 ± 0.026 V day -1 , increasing to 0.114 ± 0.073 V day -1 during storage to first use and to 0.204 ± 0.49 V day -1 during inter-deployment storage. At a representative elevated radon concentration of 500 Bq m -3 , the resulting perturbation is 3% over a 7-day deployment; at the typical mean Northamptonshire level of 80 Bq m -3 it approaches 22%. Each electret can be used for up to 25 measurements, which makes the technology attractive for organisational use. It is not suited for deployment by individual householders

  11. Radon chamber for soil gas detectors

    International Nuclear Information System (INIS)

    Andersson, P.

    1987-01-01

    Swedish Geological Co (SGAB) has designed and constructed a chamber for the calibration of detectors and instruments intended for the measurement of radon-222 in soil gas. In the chamber radon detectors may be exposed in a model environment which simulates ground conditions with respect to radon concentration, temperature and humidity. Also included in the research project is the development of methods for calibration procedures, together with test measurements. In general, these measurements indicate that the radon detectors tested are sufficiently accurate and reliable for radon measurements in Swedish soils if they are calibrated in an environment which simulates ground conditions. (orig./HP)

  12. A contemporary method for monitoring indoor radon and environmental conditions at a remote test site

    International Nuclear Information System (INIS)

    Renken, K.J.; Coursin, S.

    1996-01-01

    A state-of-the-art method for automatically monitoring indoor radon and environmental conditions at a remote test site is described. A Wisconsin home that exhibited elevated radon levels has been installed with automated PC-data acquisition system (PC-DAS) that includes: a laptop PC, a data acquisition cardcage, a commercial data acquisition software program plus sensors to measure radon gas concentrations, differential pressures, indoor air quality and meteorological conditions. The isolated PC-DAS is connected to a PC in a university laboratory via a modem and a communications software package. Experimental data is monitored and saved by the remote PC in real time and then automatically downloaded to the lab computer at selected intervals. An example of the formatted field results is presented and analysed. This documentation of the set-up, the off-the-shelf computer hardware and software, and the procedures should assist investigations requiring flexible remote long-term radon and environmental monitoring. (Author)

  13. Radon as an indicator of environmental contamination by hydrocarbons in free-phase

    International Nuclear Information System (INIS)

    Mateus, Crislene

    2016-01-01

    Contaminated sites by NAPL (Non-Aqueous Phase-Liquids) may lead to safety risks to human health and to ecosystems, restrictions to urban development and decrease of real estate value. This work used the radon gas as an indicator for the analysis of subsurface soil gas, once this noble gas presents good solubility in a wide range of NAPL, being partially retained in the NAPL contamination. Therefore, a decrease of the activity of radon in the contaminated soil gas can be expected, due to the high capacity of partitioning of radon in NAPL, which allows that the NAPL retain part of the radon previously available in the soil pores. The survey was carried out at a disused industry, contaminated by low volatile NAPL, located at southeast of Sao Paulo city, from June/14 to May/15. Radon was evaluated by passive detection methodology with CR-39 solid state nuclear track detectors (SSNTD) in ten monitoring stations installed in the contaminated area investigated and named 'A' to 'J'. Radon concentrations average for the eight monitoring stations at non-contaminated locations varied from (22 ± 4) kBq.m -3 to (39 ± 4) kBq.m -3 . For the two monitoring stations assumed as contaminated locations, radon concentrations average were (1.4 ± 0.4) kBq.m -3 and (13 ± 9) kBq.m -3 . The results have shown good agreement between the used method and the conventional environmental investigation techniques, for the majority of the monitoring stations in different seasons. Results obtained with CR-39 detectors varied over the exposure time due to the different seasons. No relation was observed between radon activity concentrations and rain volume accumulated over the different CR-39 exposure times. The lowest 222 Rn activity concentrations occurred in 'G' and 'H' monitoring stations, also verifying by gamma-ray spectrometry, that the low activities are not related to the activity concentration of its father 226 Ra from the 238 U decay chain

  14. Radon and radon daughters indoors, problems in the determination of the annual average

    International Nuclear Information System (INIS)

    Swedjemark, G.A.

    1984-01-01

    The annual average of the concentration of radon and radon daughters in indoor air is required both in studies such as determining the collective dose to a population and at comparing with limits. Measurements are often carried out during a time period shorter than a year for practical reasons. Methods for estimating the uncertainties due to temporal variations in an annual average calculated from measurements carried out during various lengths of the sampling periods. These methods have been applied to the results from long-term measurements of radon-222 in a few houses. The possibilities to use correction factors in order to get a more adequate annual average have also been studied and some examples have been given. (orig.)

  15. Project radon final report

    International Nuclear Information System (INIS)

    Ekholm, S.; Rossby, U.

    1990-01-01

    The main radiation problem in Sweden is due to radon in dwellings. At the Swedish State Power Board, R, D and D about radon has been going on since 1980. The work has concentrated on the important questions: How to find building with enhanced radon levels?; How to accurately decide on measures that will give adequate cleaning-up results, using appropriate measurement procedures; What cleaning-up effect is possible to achieve with an electro-filter?; and What cleaning-up effects are possible to achieve with different types of ventilation systems? The R, D and D-work, has been pursued in cooperation with universities of technology in Denmark and Finland, equipment manufacturers, consultants and authorities concerned. It was decided in December 1986 to give an offer to some SSPB-employees to investigate the radon situation of their dwellings, in order to test methods of measurement and cleaning-up under realistic conditions and to develop the methods to commercial maturity. The investigation was named 'Project Radon' and was carried out in three years with costs amounting to 1 M dollars. During the project less comprehensive radon measurements, named 'trace-measurements' were undertaken in about 1300 dwellings and more elaborate measurements, leading to suggestions of actions to be taken, in about 400 dwellings. Out of the suggestions, about 50 are carried out including control measurement after actions taken. The control measurement have shown that the ability to suggest appropriate actions is very successful - in just one case was a minor additional action necessary. The high reliability is achieved by always doing elaborate measurements before suggested mitigation method is decided on. (authors)

  16. The radon

    International Nuclear Information System (INIS)

    1998-01-01

    This booklet is intended to answer briefly the most important questions about the nature and sources of radon, its pathways from environment to organism, as well as the ways to minimize its concentration in the habitat's atmosphere. The radon is a naturally appearing radioactive gas, produced through the decay of uranium and radium present in the terrestrial crust. It can be found everywhere on the planet's surface and it is emitted particularly from the granite and volcanic underground rocks as well as from certain construction materials. It is one of the agents producing pulmonary cancer, although not so dangerous as the tobacco is. The following items are elaborated in this booklet: - the place of radon in the average exposure to ionizing radiations of the French population; - the risk; - the radon in the environment (the meteorological conditions, the nature of the rocks); - radon in dwellings (radon measurements in the French dwellings, the entrance pathways of radon, the dependence of radon concentration on the profession and way of life of the inhabitants); - radon measurements; - how to reduce the radon concentration in dwellings

  17. Radon removal from gaseous xenon with activated charcoal

    Energy Technology Data Exchange (ETDEWEB)

    Abe, K.; Hieda, K.; Hiraide, K.; Hirano, S.; Kishimoto, Y.; Kobayashi, K.; Koshio, Y. [Kamioka Observatory, Institute for Cosmic Ray Research, University of Tokyo, Kamioka, Hida, Gifu 506-1205 (Japan); Liu, J.; Martens, K. [Institute for the Physics and Mathematics of the Universe, University of Tokyo, Kashiwa, Chiba 277-8582 (Japan); Moriyama, S. [Kamioka Observatory, Institute for Cosmic Ray Research, University of Tokyo, Kamioka, Hida, Gifu 506-1205 (Japan); Nakahata, M. [Kamioka Observatory, Institute for Cosmic Ray Research, University of Tokyo, Kamioka, Hida, Gifu 506-1205 (Japan); Institute for the Physics and Mathematics of the Universe, University of Tokyo, Kashiwa, Chiba 277-8582 (Japan); Nishiie, H.; Ogawa, H.; Sekiya, H.; Shinozaki, A. [Kamioka Observatory, Institute for Cosmic Ray Research, University of Tokyo, Kamioka, Hida, Gifu 506-1205 (Japan); Suzuki, Y. [Kamioka Observatory, Institute for Cosmic Ray Research, University of Tokyo, Kamioka, Hida, Gifu 506-1205 (Japan); Institute for the Physics and Mathematics of the Universe, University of Tokyo, Kashiwa, Chiba 277-8582 (Japan); Takachio, O.; Takeda, A.; Ueshima, K.; Umemoto, D. [Kamioka Observatory, Institute for Cosmic Ray Research, University of Tokyo, Kamioka, Hida, Gifu 506-1205 (Japan); and others

    2012-01-01

    Many low background experiments using xenon need to remove radioactive radon to improve their sensitivities. However, no method of continually removing radon from xenon has been described in the literature. We studied a method to remove radon from xenon gas through an activated charcoal trap. From our measurements we infer a linear relationship between the mean propagation velocity v{sub Rn} of radon and v{sub Xe} of xenon in the trap with v{sub Rn}/v{sub Xe}=(0.96{+-}0.10) Multiplication-Sign 10{sup -3} at -85 Degree-Sign C. As the mechanism for radon removal in this charcoal trap is its decay, knowledge of this parameter allows us to design an efficient radon removal system for the XMASS experiment. The verification of this system found that it reduces radon by a factor of 0.07, which is in line with its expected average retention time of 14.8 days for radon.

  18. Radon dynamics in underwater thermal radon therapy

    International Nuclear Information System (INIS)

    Lettner, H.; Hofmann, W.; Winkler, R.; Rolle, R.; Foisner, W.

    1998-01-01

    At a facility for underwater thermal radon therapy in Bad Hofgastein, experiments were carried out with the aim of establishing radon in the air exhaled by the treated patients and of radon decay products on the skin of the patients. The time course of radon concentration in the exhaled air shows a maximum a few minutes after entering the bath, then the Rn concentration remains constant over the remaining time spent in the bath. Taking into account several simplifying assumptions, the average dose to the epidermis from radon daughters is about 50 μGy. (A.K.)

  19. Radon in Schools

    Science.gov (United States)

    ... Search Search Radon Contact Us Share Radon in Schools Related Information Managing Radon in Schools Radon Measurement ... Radon Could Be a Serious Threat to Your School Chances are you've already heard of radon - ...

  20. Radon emanometric technique for 226Ra estimation

    International Nuclear Information System (INIS)

    Mandakini Maharana; Sengupta, D.; Eappen, K.P.

    2010-01-01

    Studies on natural background radiation show that the major contribution of radiation dose received by population is through inhalation pathway vis-a-vis contribution from radon ( 222 Rn) gas. The immediate parent of radon being radium ( 226 Ra), it is imperative that radium content is measured in the various matrices that are present in the environment. Among the various methods available for the measurement of radium, gamma spectrometry and radiochemical method are the two extensively used measurement methods. In comparison with these two methods, the radon emanometric technique, described here, is a simple and convenient method. The paper gives details of sample processing, radon bubbler, Lucas cell and the methodology used in the emanometric method. Comparison of emanometric method with gamma spectrometry has also undertaken and the results for a few soil samples are given. The results show a fairly good agreement among the two methods. (author)

  1. Development of a quality assured calibration method for the PSI radon chamber reference atmosphere

    International Nuclear Information System (INIS)

    Schuler, C.; Butterweck-Dempewolf, G.; Vezzu, G.

    1997-01-01

    Radon detectors and measuring instruments are calibrated at the PSI Reference Laboratory for Radon Gas Concentration Measurements by exposing them to a calibrated radon reference atmosphere in the PSI radon chamber. A sophisticated and quality assured calibration technique was developed which guarantees the traceability of this radon chamber reference atmosphere to standards of internationally acknowledged primary laboratories. (author) 2 figs., 2 refs

  2. Radon in houses due to radon in potable water

    International Nuclear Information System (INIS)

    Hess, C.T.; Korsah, J.K.; Einloth, C.J.

    1987-01-01

    Radon concentration in the air of 10 houses has been measured as a function of water use and meterological parameters such as barometric pressure, wind velocity and direction, indoor and outdoor temperature, and rainfall. Results of calibrations and data collected in winter, spring, fall, and summer are given for selected houses. Average values of radon concentration in air are from 0.80 to 77 rhoCi/1. Water use average ranges from 70 to 240 gal/day. Average potential alpha energy concentrations in these houses range from 0.02 to 1.6 working levels. The radon level due to water use ranges from 0 to 36% of the house radon from soil and water combined. The radon level change due to use of a filter on the water supply shows a 60% reduction in radon in the house. Conclusions are that water radon can be a major fraction of the radon in houses. The ratio of airborne radon concentration due to water use to the radon concentration in water is 4.5 x 10/sup -5/ - 13 x 10/sup -5/

  3. The discussion on a new measure method of radon chamber leak rate

    International Nuclear Information System (INIS)

    Zhang Junkui; Tang Bing

    2010-01-01

    Radon chamber is the third standard radon source. The leak rate is the key parameter for the radon chamber to naturally and safely operate. One way, that measure the leak rate is introduced. The experience result is that the way is simple and veracious to measure the leak rate. (authors)

  4. Measurement of radon permeability through polyethylene membrane using scintillation detector

    Energy Technology Data Exchange (ETDEWEB)

    Ashry, A.H.; Abou-Leila, M. [Department of Physics, Faculty of Education, Ain Shams University, Cairo (Egypt); Abdalla, A.M., E-mail: aymanabdalla62@hotmail.co [Department of Physics, Faculty of Education, Ain Shams University, Cairo (Egypt); Department of Physics, Faculty of Sciences and Arts, Najran University, Najran, P.O. Box. 11001 (Saudi Arabia); Advanced Materials and Nano-Engineering Laboratory (AMNEL), Centre for Advanced Materials and Nano-Engineering (CAMNE), Najran University, Najran, P.O. Box. 11001 (Saudi Arabia)

    2011-01-15

    The permeability of Radon 222 through polyethylene membranes has been studied using activated charcoal technique. The permeability constant of Radon 222 through low-density polyethylene, linear low-density Polyethylene and high density polyethylene samples has been measured. There is a considerable agreement between the values obtained by our method and the method suggested by W. Arafa [2002. Permeability of radon 222 through some materials. Radiat. Meas. 35, 207-211], and SSNTD technique suggested by A. Hafez and G. Somogyi [1986. Determination of radon and thoron permeability through some plastics by track technique. Int. J. Radiat. Appl. Instrum. Nucl. Track Radiat. Meas. 12 (1-6), 697-700]. In this work Radon permeability through different polyethylene membranes has been measured using three different methods, i.e. solid state nuclear track technique, W. Arafa [2002. Permeability of radon 222 through some materials. Radiat. Meas. 35, 207-211]method and our proposed method. In addition to this, in this study, the diffusion coefficient of radon in charcoal as well as solubility of Radon in polyethylene membrane has been taken into consideration.

  5. Measurement of radon permeability through polyethylene membrane using scintillation detector

    International Nuclear Information System (INIS)

    Ashry, A.H.; Abou-Leila, M.; Abdalla, A.M.

    2011-01-01

    The permeability of Radon 222 through polyethylene membranes has been studied using activated charcoal technique. The permeability constant of Radon 222 through low-density polyethylene, linear low-density Polyethylene and high density polyethylene samples has been measured. There is a considerable agreement between the values obtained by our method and the method suggested by W. Arafa [2002. Permeability of radon 222 through some materials. Radiat. Meas. 35, 207-211], and SSNTD technique suggested by A. Hafez and G. Somogyi [1986. Determination of radon and thoron permeability through some plastics by track technique. Int. J. Radiat. Appl. Instrum. Nucl. Track Radiat. Meas. 12 (1-6), 697-700]. In this work Radon permeability through different polyethylene membranes has been measured using three different methods, i.e. solid state nuclear track technique, W. Arafa [2002. Permeability of radon 222 through some materials. Radiat. Meas. 35, 207-211] method and our proposed method. In addition to this, in this study, the diffusion coefficient of radon in charcoal as well as solubility of Radon in polyethylene membrane has been taken into consideration.

  6. Radon in Danish dwellings. Mapping of stall, county and municipality values

    International Nuclear Information System (INIS)

    Andersen, C.E.; Damkjaer, A.; Ulbak, K.; Gravesen, P.

    2001-01-01

    A survey of radon in Danish dwellings has been carried out. The concentration of radon-222 has been measured in 3019 single-family houses and 101 multi-family houses (apartment complexes) with the so-called alpha-track technique (CR-39). On this basis, a map has been established. This map shows the percentage of single-family houses in each of the 275 municipalities with levels above 200 Bq/m 3 (i.e.) the action level recommended by the Danish building authorities for simple radon remedi-action). For Denmark as a whole, 4.6 % of the single-family houses are above 200 Bq/m 3 . That corresponds to 65 000 houses. In certain parts of the country (e.g. northern Jutland) less than 1 % are above 200 Bq/m 3 . In other places (e.g. certain parts of Funen and Bornholm) the value is above 10 %. In the survey, 15 houses had levels above 400 Bq/m 3 . The relationship between radon and various factors has been investigated with regression analysis. The three most important factors are type of basement, province, and soil type. The analysis confirms that the soil below the houses is the most important source of radon in Danish single-family houses. The study also provides a more detailed picture of the relation between geology and indoor radon. For example, it is shown that clayey till generates different indoor radon levels in the different parts of the country. The study does not indicate that a substantial part of newer Danish houses have an airtight house-soil interface. The report includes a summary in English. (au)

  7. Radon

    International Nuclear Information System (INIS)

    Holmen, R.W.

    1987-01-01

    The discovery that radon enters into residential and commercial structures and produces adverse health consequences to occupants thereof has raised issues for the real estate profession in connection with transactions involving affected structures. The legal responsibilities of real estate professionals in relation to such structures have not yet been clearly defined. Moreover, consistent and reliable testing methods and results, clear identification of circumstances where testing is necessary, and consensus as to health risks suggested by various radon levels have yet to be achieved. When these legal and technical questions are clarified, real estate buyer and sellers as well as agents and brokers will be greatly benefited

  8. Environmental radon and cancer risk

    Energy Technology Data Exchange (ETDEWEB)

    Haque, A K.M.M.; Kirk, A E [South Bank Polytechnic, London (United Kingdom)

    1992-01-01

    Data collected from the office of Population Censuses and Surveys (OPCS) statistics and those published by the Leukaemia Research Fund (LRF) have been analysed with a view to examining whether radon is a possible causative agent in the induction of leukaemias. Radon concentration values have been taken from a NRPB survey. Positive correlation has been observed between radon concentration and incidence of acute myeloid leukaemia (AML), chronic myeloid leukaemia (CML), acute lymphoblastic leukaemia (ALL) and chronic lymphoid leukaemia (CLL). Employing the method of BEIR IV, the lifetime probability of leukaemia incidence, R[sub o], of a non-exposed person (zero radon concentration) has been calculated for AML, CML, ALL and CLL, which agree well with those values obtained from extrapolation of linear graphs of leukaemia deaths versus radon concentration. (author).

  9. Indoor Air '93. Particles, microbes, radon

    International Nuclear Information System (INIS)

    Kalliokoski, P.; Jantunen, M.; Seppaenen, O.

    1993-01-01

    The conference was held in Helsinki, Finland, July 4-8, 1993. The proceedings of the conference were published in 6 volumes. The main topics of the volume 5 are: (1) particles, fibers and dust - their concentrations and sources in buildings, (2) Health effects of particles, (3) Need of asbestos replacement and encapsulation, (4) Seasonal and temporal variation of fungal and bacterial concentration, (5) The evaluation of microbial contamination of buildings, (6) New methods and comparison of different methods for microbial sampling and evaluation, (7) Microbes in building materials and HVAC-systems, (8) Prevention of microbial contamination in buildings, (9) Dealing with house dust mites, (10) Radon measurements and surveys in different countries, (11) The identification of homes with high radon levels, (12) The measurement methods and prediction of radon levels in buildings, and (13) Prevention of radon penetration from the soil

  10. Portable monitors for measuring radon and its progenies air by intergrated sampling method

    International Nuclear Information System (INIS)

    Zhang Huaiqin; Su Jingling; Yao Wanyuan; Liu Jinhua

    1989-01-01

    Two kinds of portable monitors have been developed, which can be used to measure the concentration of radon or potential energy concentration of radon or potential energy concentration of radon progenies in air. The thermoluminescent material CaSO 4 (Tm) is used as a detecting element for both of them. The lowest detectable limit of the passive radon monitor is about 1.5 Bq/m 3 for radon in air, as the exposure time being one week. Its main advantages are high reliability and convenient manipulation. The working level monitor for radon progenies in air consists of a mini membrane pump and an integrating probe. The lowest detectable limit is about 6.2 x 10 -9 J/m 3 , as the sampling time being 6 hours. It weights only about 0.35 kg

  11. Ground-truthing predicted indoor radon concentrations by using soil-gas radon measurements

    International Nuclear Information System (INIS)

    Reimer, G.M.

    2001-01-01

    Predicting indoor radon potential has gained in importance even as the national radon programs began to wane. A cooperative study to produce radon potential maps was conducted by the Environmental Protection Agency (EPA), U.S. Geological Survey (USGS), Department of Energy (DOE), and Lawrence Berkeley Laboratory (LBL) with the latter taking the lead role. A county-wide predictive model based dominantly on the National Uranium Resource Evaluation (NURE) aerorad data and secondly on geology, both small-scale data bases was developed. However, that model breaks down in counties of complex geology and does not provide a means to evaluate the potential of an individual home or building site. Soil-gas radon measurements on a large scale are currently shown to provide information for estimating radon potential at individual sites sort out the complex geology so that the small-scale prediction index can be validated. An example from Frederick County, Maryland indicates a positive correlation between indoor measurements and soil-gas data. The method does not rely on a single measurement, but a series that incorporate seasonal and meteorological considerations. (author)

  12. Robustness study in SSNTD method validation: indoor radon quality

    Energy Technology Data Exchange (ETDEWEB)

    Dias, D.C.S.; Silva, N.C.; Bonifácio, R.L., E-mail: danilacdias@gmail.com [Comissao Nacional de Energia Nuclear (LAPOC/CNEN), Pocos de Caldas, MG (Brazil). Laboratorio de Pocos de Caldas

    2017-07-01

    Quality control practices are indispensable to organizations aiming to reach analytical excellence. Method validation is an essential component to quality systems in laboratories, serving as a powerful tool for standardization and reliability of outcomes. This paper presents a study of robustness conducted over a SSNTD technique validation process, with the goal of developing indoor radon measurements at the highest level of quality. This quality parameter indicates how well a technique is able to provide reliable results in face of unexpected variations along the measurement. In this robustness study, based on the Youden method, 7 analytical conditions pertaining to different phases of the SSNTD technique (with focus on detector etching) were selected. Based on the ideal values for each condition as reference, extreme levels regarded as high and low were prescribed to each condition. A partial factorial design of 8 unique etching procedures was defined, where each presented their own set of high and low condition values. The Youden test provided 8 indoor radon concentration results, which allowed percentage estimations that indicate the potential influence of each analytical condition on the SSNTD technique. As expected, detector etching factors such as etching solution concentration, temperature and immersion time were identified as the most critical parameters to the technique. Detector etching is a critical step in the SSNTD method – one that must be carefully designed during validation and meticulously controlled throughout the entire process. (author)

  13. Robustness study in SSNTD method validation: indoor radon quality

    International Nuclear Information System (INIS)

    Dias, D.C.S.; Silva, N.C.; Bonifácio, R.L.

    2017-01-01

    Quality control practices are indispensable to organizations aiming to reach analytical excellence. Method validation is an essential component to quality systems in laboratories, serving as a powerful tool for standardization and reliability of outcomes. This paper presents a study of robustness conducted over a SSNTD technique validation process, with the goal of developing indoor radon measurements at the highest level of quality. This quality parameter indicates how well a technique is able to provide reliable results in face of unexpected variations along the measurement. In this robustness study, based on the Youden method, 7 analytical conditions pertaining to different phases of the SSNTD technique (with focus on detector etching) were selected. Based on the ideal values for each condition as reference, extreme levels regarded as high and low were prescribed to each condition. A partial factorial design of 8 unique etching procedures was defined, where each presented their own set of high and low condition values. The Youden test provided 8 indoor radon concentration results, which allowed percentage estimations that indicate the potential influence of each analytical condition on the SSNTD technique. As expected, detector etching factors such as etching solution concentration, temperature and immersion time were identified as the most critical parameters to the technique. Detector etching is a critical step in the SSNTD method – one that must be carefully designed during validation and meticulously controlled throughout the entire process. (author)

  14. Method for measurement of radon diffusion and solubility in solid materials

    Science.gov (United States)

    Maier, Andreas; Weber, Uli; Dickmann, Jannis; Breckow, Joachim; van Beek, Patrick; Schardt, Dieter; Kraft, Gerhard; Fournier, Claudia

    2018-02-01

    In order to study the permeation i.e. the diffusion and solubility of radon gas in biological material, a new setup was constructed and a novel analysis was applied to obtain diffusion and solubility coefficients. Thin slabs of solid materials were installed between detector housing and the surrounding radon exposure chamber of 50 Ls volume. In this setup radon can diffuse through thin test samples into a cylindrical volume of 5 mm height and 20 mm diameter and reach an α-particle detector. There the 5.49 MeV α-decay of the penetrating radon atoms is measured by a silicon surface barrier detector. The time dependent activities inside the small detector volume are recorded after injection of a known radon activity concentration into the outer chamber. Analyzing the time behavior of the integral α-activity from radon in the small vessel, both, the diffusion coefficient and solubility of the test material can be determined, based on a new mathematical model of the diffusion process concerning the special boundary conditions given by the experimental setup. These first measurements were intended as proof of concept for the detection system and the data analysis. Thin polyethylene foils (LDPE) were selected as material for the diffusion measurements and the results were in agreement with data from literature. In further measurements, we will concentrate on biological material like bone, fat and other tissues.

  15. Ethanol as radon storage: applications for measurement

    International Nuclear Information System (INIS)

    Winter, I.; Philipsborn, H. von

    1997-01-01

    Ethanol as Radon Storage: Applications for Measurement Ethanol has a solubility for radon of 6 Bq/l per kBq/m 3 air, 24 times higher than water. On filtration of ethanol, radon decay products are completely adsorbed on glass fiber filters, as previously reported for water. Hence: 1. A new simple method for measuring radon in soil air, without expensive equipment. 2. The production of mailable radon calibration sources ('radonol') with 50-100 kBq/l in PET-bottles with 3.8 days half-life, using uraniferous rocks as primary source. (orig.) [de

  16. Assessing the risks from exposure to radon in dwellings

    International Nuclear Information System (INIS)

    Walsh, P.J.; Lowder, W.M.

    1983-07-01

    The factors used to assess the radiation dose and health risks from human exposure to radon in dwellings are critically reviewed in this summary. Sources of indoor radon and determinants of air concentrations and exposure levels are given as well as the uncertainties that exist in their formulation. Methods of assessing health effects from inhalation of radon and its progeny are discussed with emphasis on dosimetry of radon daughters and formulation of risk per dose values. Finally, methods of assessing risks for general population exposures to indoor radon concentrations are treated

  17. Radon: a case for public persuasion

    International Nuclear Information System (INIS)

    Green, B.M.R.; Lomas, P.R.

    1996-01-01

    The importance of reducing individual to elevated levels of radon is well understood by radiation protection specialists, and successful methods of locating the areas most at risk have been developed. However, less attention has been paid to informing the general public about the health rifles and encouraging those in radon-prone areas to take action. In the United Kingdom, techniques have been developed to persuade householders in high radon areas to take advantage of a government scheme that provides free long-term measurements of radon in the home. Improvements in the methods of contacting householders in the target areas and in the presentation of the facts has resulted in a twofold increase in the rate of take-up of measurements since the first large-scale surveys. (author)

  18. Radon and health

    International Nuclear Information System (INIS)

    Chobanova, Nina

    2016-01-01

    Radon is radioactive noble gas that can be found in soil, water, outdoor and indoor air. Since environmental radon on average accounts for about half of all human exposure to radiation from natural sources, increasing attention has been paid to exposure to radon and its associated health risks. Many countries have introduced regulations to protect their population from radon in dwellings and workplaces. In this article are discussed main characteristics of radon, including sources of exposure, variation in radon exposure, how managing risks from radon exposure, how to measure the concentration of radon. There are results of measurements conducted under the 'National radon programme' in Bulgaria also. Key words: radon, sources of exposure, risk, cancer, measure to decrease the concentration [bg

  19. Realization of radioactive equilibrium in the KRISS radon chamber

    International Nuclear Information System (INIS)

    Lee, Mo Sung; Park, Tae Soon; Lee, Jong Man

    2013-01-01

    The maintenance of radioactive equilibrium between radon and its decay products in a radon chamber is necessary to calibrate radon decay product monitors. In this study, the activity concentrations of radon decay products have been measured, and mosquito-repellent incense has been used to produce aerosol particles in the chamber. Filter papers with 8 μm pore size were used to collect aerosol in the chamber. The activity concentrations of radon decay products have been evaluated by the Modified Tsivoglou Method. The correction factors due to the differences in counting time requirements of the Modified Tsivoglou Method and the time delay between consecutive measurements have been determined. Finally, the radioactive equilibrium has been confirmed by applying the Bateman equation. - Highlights: • The activity concentrations of radon decay products are evaluated by the Modified Tsivoglou Method. • Mosquito-repellent incense is used to produce aerosol particles in the radon chamber. • The radioactive equilibrium in the chamber was achieved within 2 days and confirmed by the Bateman equation

  20. Relationship between indoor radon concentrations and air exchange rate

    International Nuclear Information System (INIS)

    Wang Jingshu; Liu Yuyu; Yao Xiaohua; Meng Jianfeng; Zhang Yongyi; Wang Xiaohe; Yu Xiufen.

    1995-01-01

    The indoor concentration of radon and the air exchange rate were simultaneously measured in four empty rooms, made of brick and cement, which were located in different floors of dwelling houses in Taiyuan, Shanxi, China. SF 6 tracer gas decay method was used to measure the air exchange rate. Indoor radon was collected with the dimembrane method. When the ventilation rate increased, the concentration of radon dropped rapidly. Regression analysis indicated that the indoor concentration of radon was equal to the outdoor level of radon when the air exchange rate was greater than 3-4. SF 6 decay method was an effective and convenient method for measuring the air exchange rate. There was no marked difference in measurements obtained in different locations of a room. (N.K.)

  1. Volume traps - a new retrospective radon monitor

    International Nuclear Information System (INIS)

    Oberstedt, S.; Vanmarcke, H.

    1994-11-01

    A new method to trace back average radon concentrations in dwellings over several decades in time has been developed. This retrospective radon monitor is based on the measurement of the alpha activity of 210 Po deposited in volume traps, for example spongy materials used for mattresses and cushions. Polyester samples with different densities have been exposed to radon-laden air. The exposures correspond to characteristic radon concentrations between 390 Bq/m 3 and 3.9 Bq/m 3 over a 20 years period. The precision in converting the 210 Po signal to the radon exposure has been improved by more than one order of magnitude compared to other common techniques. It is shown that this very sensitive method may be applied to almost all types of volume traps used in households

  2. Locating and limiting radon in dwellings

    International Nuclear Information System (INIS)

    Hildingson, O.; Gustafsson, J.; Nilsson, I.

    1984-01-01

    More than 3,300 Swedish dwellings have an indoor radon daughter concentration above 400 Bq.m -3 (or 0.108 WL). It is considered to be unsafe to live in any of these dwellings and the radon daughter concentration has to be reduced. Before deciding what measures to take, it is important to determine the radon sources. Possible sources are exhalation from building materials and/or radon transport from the ground into the building through cracks and joints in the slab. Different methods of locating the sources have been developed. To locate cracks and joints in slabs the ventilation rate and the air pressure difference relative to the ground are changed while monitoring radon/radon daughter concentration. The effect of five different measures to reduce the indoor radon daughter concentration have also been evaluated: increased ventilation rate by mechanical ventilation, ventilation of the small spaces between the floor and the slab, sealing the surface of radon exhaling walls, sealing joints and cracks in the slab, and ventilation of the drainage under the slab. (author)

  3. Modelling of radon transport in porous media

    NARCIS (Netherlands)

    van der Graaf, E.R.; de Meijer, R.J.; Katase, A; Shimo, M

    1998-01-01

    This paper aims to describe the state of the art of modelling radon transport in soil on basis of multiphase radon transport equations. Emphasis is given to methods to obtain a consistent set of input parameters needed For such models. Model-measurement comparisons with the KVI radon transport

  4. Predicting radon/radon daughter concentrations in underground mines

    International Nuclear Information System (INIS)

    Leach, V.A.

    1984-01-01

    A detailed description of a computer programme is outlined for the calculation of radon/radon daughter concentrations in air. This computer model is used to predict the radon/radon daughter concentrations in Working Level (WL) at the workplace and at the various junctions at either end of the branches in a typical ventilation network proposed for the Jabiluka mine in the Northern Territory

  5. Radon flux measurement methodologies

    International Nuclear Information System (INIS)

    Nielson, K.K.; Rogers, V.C.

    1984-01-01

    Five methods for measuring radon fluxes are evaluated: the accumulator can, a small charcoal sampler, a large-area charcoal sampler, the ''Big Louie'' charcoal sampler, and the charcoal tent sampler. An experimental comparison of the five flux measurement techniques was also conducted. Excellent agreement was obtained between the measured radon fluxes and fluxes predicted from radium and emanation measurements

  6. Intercomparison of different instruments for measuring radon concentration in air

    International Nuclear Information System (INIS)

    Shimo, Michikuni; Iida, Takao

    1990-01-01

    An intercomparison of different instruments for measurement of radon concentration was carried out. The instruments include an ionization chamber, the charcoal-trap method, a flow-type ionization chamber (pulse-counting method), a two-filter method, an electrostatic collection method and a passive integration radon monitor. All instruments except for the passive radon monitor have been calibrated independently. Measurements were performed over a concentration range from about 3.5 Bq·m -3 (in outdoor air) to 110 Bq·m -3 (in indoor air). The results obtained by these techniques, except the two-filter technique, are comparable. Radon daughter concentration measured using a filter-sampling method was about 52% of radon concentration. (author)

  7. Comparison of radon diffusion coefficients measured by transient-diffusion and steady-state laboratory methods

    International Nuclear Information System (INIS)

    Kalwarf, D.R.; Nielson, K.K.; Rich, D.C.; Rogers, V.C.

    1982-11-01

    A method was developed and used to determine radon diffusion coefficients in compacted soils by transient-diffusion measurements. A relative standard deviation of 12% was observed in repeated measurements with a dry soil by the transient-diffusion method, and a 40% uncertainty was determined for moistures exceeding 50% of saturation. Excellent agreement was also obtained between values of the diffusion coefficient for radon in air, as measured by the transient-diffusion method, and those in the published literature. Good agreement was also obtained with diffusion coefficients measured by a steady-state method on the same soils. The agreement was best at low moistures, averaging less than ten percent difference, but differences of up to a factor of two were observed at high moistures. The comparison of the transient-diffusion and steady-state methods at low moistures provides an excellent verification of the theoretical validity and technical accuracy of these approaches, which are based on completely independent experimental conditions, measurement methods and mathematical interpretations

  8. Radon in homes of the Portland, Oregon Area: Radon data from local radon testing companies collected by CRM (Continuous Radon Measurement) machines

    Science.gov (United States)

    Whitney, H.; Lindsey, K.; Linde, T.; Burns, S. F.

    2013-12-01

    Students from the Department of Geology at Portland State University paired up with the Oregon Health Authority to better understand radon gas values in homes of the Portland metropolitan area. This study focuses on radon values collected by continuous radon measurement (CRM) machines, taken by local radon testing companies. The local companies participating in this study include Alpha Environmental Services, Inc., Cascade Radon, Environmental Works, The House Detectives, LLC, and Soil Solutions Environmental Services, Inc. In total, 2491 radon readings spanning across 77 zip codes were collected from local companies in the Portland metropolitan area. The maximum value, average value, percentage of homes greater than 4 pCi/L and total rank sum was calculated and used to determine the overall radon potential for each zip code (Burns et al., 1998). A list and four maps were produced showing the results from each category. Out of the total records, 24 zip codes resulted in high radon potential and the average reading for the entire Portland Metropolitan area was 3.7 pCi/L. High potential zip codes are thought to be a result of sand and gravel (Missoula Flood deposits) and faults present in the subsurface. The CRM data was compared with both long-term and short-term data provided by the Oregon Health Authority to validate radon potentials in each zip code. If a home is located in a zip code with high or moderate radon potential across two types of data sets, it is recommended that those homes be tested for radon gas.

  9. Standardised Radon Index (SRI: a normalisation of radon data-sets in terms of standard normal variables

    Directory of Open Access Journals (Sweden)

    R. G. M. Crockett

    2011-07-01

    Full Text Available During the second half of 2002, from late June to mid December, the University of Northampton Radon Research Group operated two continuous hourly-sampling radon detectors 2.25 km apart in the English East Midlands. This period included the Dudley earthquake (ML = 5, 22 September 2002 and also a smaller earthquake in the English Channel (ML = 3, 26 August 2002. Rolling/sliding windowed cross-correlation of the paired radon time-series revealed periods of simultaneous similar radon anomalies which occurred at the time of these earthquakes but at no other times during the overall radon monitoring period. Standardising the radon data in terms of probability of magnitude, analogous to the Standardised Precipitation Indices (SPIs used in drought modelling, which effectively equalises different non-linear responses, reveals that the dissimilar relative magnitudes of the anomalies are in fact closely equiprobabilistic. Such methods could help in identifying anomalous signals in radon – and other – time-series and in evaluating their statistical significance in terms of earthquake precursory behaviour.

  10. Nonlinear Radon Transform Using Zernike Moment for Shape Analysis

    Directory of Open Access Journals (Sweden)

    Ziping Ma

    2013-01-01

    Full Text Available We extend the linear Radon transform to a nonlinear space and propose a method by applying the nonlinear Radon transform to Zernike moments to extract shape descriptors. These descriptors are obtained by computing Zernike moment on the radial and angular coordinates of the pattern image's nonlinear Radon matrix. Theoretical and experimental results validate the effectiveness and the robustness of the method. The experimental results show the performance of the proposed method in the case of nonlinear space equals or outperforms that in the case of linear Radon.

  11. Personal radon daughter dosimetry

    International Nuclear Information System (INIS)

    Stocker, H.

    1979-12-01

    The conventional means of radon daughter exposure estimatikn for uranium miners in Canada is by grab sampling and time weighting. Personal dosimetry is a possible alternative method with its own advantages and limitations. The author poses basic questions with regard to two methods of radon daughter detection, thermoluminescent chips and track-etch film. An historical review of previous and current research and development programs in Canada and in other countries is presented, as are brief results and conclusions of each dosimeter evaluation

  12. Measurements of radon concentrations in dwelling houses

    International Nuclear Information System (INIS)

    Birkholz, W.; Klink, T.

    1993-01-01

    Radon and its daughter products gain in importance in health protection and radiation safety. Especially in the southern region of Saxony radon concentrations in dwellings may be high by former silver and uranium mines. We found radon contents of about 20.000 Bq/m 3 in dwellings. To redevelop such houses it is necessary to know intrude path of radon. In present work we studied different measuring systems, active and passive detectors, short and long term integrating devices. By means of investigation of radon sources several redeveloping methods are rates as well from radiological as from civil engineering point of view. (author)

  13. Development of a radiochemical method for analyzing radon gas in uranium mine atmospheres: covering the period February 3, 1975--March 31, 1976

    Energy Technology Data Exchange (ETDEWEB)

    Stein, L.; Shearer, J.A.; Hohorst, F.A.; Markun, F.

    1977-01-14

    A simplified radiochemical method has been developed for quantitatively analyzing radon gas in underground uranium mines. In this method, a measured volume of air is drawn by a pump through a drying tube and a cartridge containing dioxygenyl hexafluoroantimonate reagent. Radon is captured as a nonvolatile product. After radioactive equilibrium has been established between radon and its short-lived daughters (approximately 4 hours), the gamma-emission of the cartridge is measured with a scintillation counter. The amount of radon is then calculated from the gamma-emission rate. The effect of cartridge geometry, reagent load, and air flow rate upon collection efficiency and counting efficiency is reported.

  14. Development of a radiochemical method for analyzing radon gas in uranium mine atmospheres: covering the period February 3, 1975--March 31, 1976

    International Nuclear Information System (INIS)

    Stein, L.; Shearer, J.A.; Hohorst, F.A.; Markun, F.

    1977-01-01

    A simplified radiochemical method has been developed for quantitatively analyzing radon gas in underground uranium mines. In this method, a measured volume of air is drawn by a pump through a drying tube and a cartridge containing dioxygenyl hexafluoroantimonate reagent. Radon is captured as a nonvolatile product. After radioactive equilibrium has been established between radon and its short-lived daughters (approximately 4 hours), the gamma-emission of the cartridge is measured with a scintillation counter. The amount of radon is then calculated from the gamma-emission rate. The effect of cartridge geometry, reagent load, and air flow rate upon collection efficiency and counting efficiency is reported

  15. Overview of current radon and radon daughter research at LBL

    International Nuclear Information System (INIS)

    1983-01-01

    This report provides a brief summary of radon and radon daughter research at Lawrence Berkeley Laboratory. The radon and radon daughter research program has two broad goals: (1) the study of sources of radon and its subsequent transport into houses, and (2) research on the behavior of radon daughters in indoor environments. Additional research effort is directed to several auxiliary areas, including development of instrumentation and monitoring techniques, studies of indoor air movement, and measurement and control of indoor particulate concentrations

  16. Radon in drinking water in Co. Wicklow. A pilot study

    International Nuclear Information System (INIS)

    Ryan, T.P.; Sequeira, S.; McKittrick, L.; Colgan, P.A.

    2003-02-01

    Attention has been focused on the issue of radon in drinking water by a European Commission recommendation proposing that surveys should be undertaken in Member States to determine the scale and nature of exposures caused by radon in domestic drinking water supplies. The Commission recommends 1000 Bq/l as the radon activity concentration in private drinking water supplies above which remedial action to reduce the concentration should be taken. The logic behind the proposed action level is that it would broadly correspond to the risk posed to an individual from exposure to radon in the home at the current Reference Level of 200 Bq/m3 in air. A pilot study to assess the distribution and concentrations of radon in private ground water supplies was recently completed in Co. Wicklow. County Wicklow was selected for the study primarily on the basis that the underlying geology is predominantly granite with elevated uranium content. Furthermore, there is an estimated 1200 to 5000 private ground water supplies in use in the county and high radon activity concentrations in air in a significant number of dwellings have previously been predicted. As part of the pilot study, a number of scientific issues were addressed in order to underpin the results obtained and these are also discussed in the report. Radon activity concentrations were measured in the private ground water supplies of 166 houses in Co. Wicklow. In all cases the ground water was the principal source of drinking water for the house occupants. Four supplies had activity concentrations in excess of the Recommended EC action level of 1000 Bq/l, fifteen had activity concentrations between 500 and 1000 Bq/l, 51 were between 100 and 500 Bq/l and 96 had activity concentrations below 100 Bq/l. The doses estimated for the ingestion of radon bearing water vary significantly with the quantity of drinking water consumed and the degree to which the water has been processed prior to consumption. However dose estimates based

  17. Radon in drinking water in Co. Wicklow. A pilot study

    International Nuclear Information System (INIS)

    Ryan, T.P.; Sequeira, S.; McKittrick, L.; Colgan, P.A.

    2003-01-01

    Attention has been focused on the issue of radon in drinking water by a European Commission recommendation proposing that surveys should be undertaken in Member States to determine the scale and nature of exposures caused by radon in domestic drinking water supplies. The Commission recommends 1000 Bq/l as the radon activity concentration in private drinking water supplies above which remedial action to reduce the concentration should be taken. The logic behind the proposed action level is that it would broadly correspond to the risk posed to an individual from exposure to radon in the home at the current Reference Level of 200 Bq/m 3 in air. A pilot study to assess the distribution and concentrations of radon in private ground water supplies was recently completed in Co. Wicklow. County Wicklow was selected for the study primarily on the basis that the underlying geology is predominantly granite with elevated uranium content. Furthermore, there is an estimated 1200 to 5000 private ground water supplies in use in the county and high radon activity concentrations in air in a significant number of dwellings have previously been predicted. As part of the pilot study, a number of scientific issues were addressed in order to underpin the results obtained and these are also discussed in the report. Radon activity concentrations were measured in the private ground water supplies of 166 houses in Co. Wicklow. In all cases the ground water was the principal source of drinking water for the house occupants. Four supplies had activity concentrations in excess of the Recommended EC action level of 1000 Bq/l, fifteen had activity concentrations between 500 and 1000 Bq/l, 51 were between 100 and 500 Bq/l and 96 had activity concentrations below 100 Bq/l. The doses estimated for the ingestion of radon bearing water varies significantly with the quantity of drinking water consumed and the degree to which the water has been processed prior to consumption. However dose estimates

  18. Radon analyser

    International Nuclear Information System (INIS)

    1981-01-01

    The process claimed includes the steps of transferring radon gas produced by a sample to a charcoal trap, cooled to a temperature whereby the radon is absorbed by the charcoal, heating the charcoal trap to a sufficient temperature to release the radon, and transferring the radon to a counting device where the gas particles are counted

  19. A summary of EPA radon chamber tests and results for rounds 3 and 4 of the National Radon Measurement Proficiency Program

    International Nuclear Information System (INIS)

    Smith, J.M.; Sensintaffar, E.L.

    1993-02-01

    The US Environmental Protection Agency's Office of Radiation and Indoor Air (ORIA) established the National Radon Measurement Proficiency (RMP) Program in 1986. Through this voluntary program, participants can demonstrate their ability to measure radon and/or radon decay products by submitting their detection devices to a blind test in a designated radon chamber. In this report, two EPA radon and radon decay products test chambers (chambers A and C) located at the National Air and Radiation Environmental Laboratory in Montgomery, Alabama are described. These chambers were used to expose detectors submitted for testing in Round 4 of the National Radon Measurement Proficiency Program and are used routinely for calibration purposes. Also described are the measurement and calibration procedures which were used to establish the official target values for radon and radon decay products concentrations during RMP Round 4 testing. The results for RMP Round 3 (conducted at the US DOE Environmental Measurements Laboratory radon chamber in New York) and RMP Round 4 (conducted in the two NAREL chambers) are discussed and compared. Following Round 4, the NAREL staff analyzed the collective performance for each measurement method tested in these rounds and found that all methods agreed with the target values within expected limits except for RPISU's and charcoal adsorbers. After analyzing the RMP4 results, NAREL staff spent several months evaluating the difference in charcoal adsorber response between Round 3 and 4 by performing radon chamber tests using EPA 4-inch, open-faced charcoal adsorbers

  20. Measurement of radon concentration in water by means of {alpha}, {gamma} spectrometry. Radon concentration in ground and spring water in Hiroshima Prefecture

    Energy Technology Data Exchange (ETDEWEB)

    Shizuma, Kiyoshi [Hiroshima Univ. (Japan)

    1997-02-01

    Radon ({sup 222}Rn, T{sub 1/2}=3.8235{+-}0.0003d) is {alpha}-ray releasing nuclide, so that it can not be detected by {gamma}-ray measurement. But, the daughter nuclides {sup 214}Pb (T{sub 1/2}=26.8 min) and {sup 214}Bi (T{sub 1/2}=19.9 min) release {gamma}-ray, accordingly they are measured by Ge detector. Their radioactive equilibrium is kept in the closed vessel, because their half-lives are shorter than that of radon. We developed a measurement method of radon concentration by means of {gamma}-spectrometry. We applied this method to catch radon in the atmosphere by active carbon. The same principle can be applied to radon in water. Radon concentrations in the ground water were measured in 22 points in the Higashi-Hiroshima city and 82 points in the Hiroshima prefecture. The efficiencies of {gamma}-ray were determined. The radon concentration showed between 11 and 459 Bq/l and the average was 123 Bq/l. The high concentration of radon was distributed in the spring of granitic layer and higher concentration of radon were observed in the ground water of fault. (S.Y.)

  1. Estimation of the Radon-induced Dose for Russia's Population: Methods and Results

    International Nuclear Information System (INIS)

    Marenny, A.M.; Savkin, M.N.; Shinkarev, S.M.

    2000-01-01

    A model is proposed for inferring the radon-induced annual average collective and personal doses, as well as the dose distribution of the population, all over Russia from selective radon monitoring in some regions of Russia. The model assumptions and the selective radon monitoring results that underlie the numerical estimates obtained for different population groups are presented. The current estimate of the collective radon-induced dose received by the population of Russia (148,100,000 as of 1996) is about 130,000 man Sv, of which 55,000 man Sv is for the rural population (27% of the total population) and 75,000 man Sv for the urban population (73% of the total). The average radon-induced personal dose in Russia is estimated to be about 0.87 mSv. About 1,000,000 people receive annual doses above 10 mSv, including some 200,000 people who receive doses above 20 mSv annually. The ways of making the current estimates more accurate are outlined. (author)

  2. Navy radon assessment and mitigation program: Final report

    International Nuclear Information System (INIS)

    1994-10-01

    This final report encompasses the events from the beginning of the Navy Radon Assessment and Mitigation Program to the closure of the program on October 31, 1994. Included in the report are discussions of the phases of the program including screening, assessment, mitigation, and post-mitigation. The primary discussion involves screening and assessment. The report addresses recommendations made to the Naval Facilities Engineering Command by the Hazardous Waste Remedial Actions Program of Martin Marietta Energy Systems, Inc., and the final decisions that were made. Special emphasis is placed on quality assurance/quality control (QA/QC), since QA/QC was given top priority during the implementation of this program. Included in the discussion on QA/QC are ana overview of the measurement process, positive and negative controls, replicated measurements, and application of chamber exposures to data calibration. The report concludes with a discussion of testing considerations for naval facilities and radon mitigation considerations for the Department of the Navy

  3. A study on the risk from indoor radon 220 and radon 222 exposures

    International Nuclear Information System (INIS)

    Rannou, A.

    1986-12-01

    The hazards from radon (radon 220 and 222) in dwelling atmospheres have been studied. In the first part devoted to the present state of the problem, an analysis is made of the formation mechanisms and the evolution of radon and its daughters indoors. The main physical and dosimetric quantities required for the risk evaluation are defined. The theoretical and experimental analysis of the methods of measurements of radon and its daughters used in the measurement campaign are considered in the second part. The progress and the result of the national survey are developed in the third part. The effects of several factors on indoor levels are discussed. The conclusions of a particular study in the Finistere ''department'' are presented. The data collected make it possible to assess the mean exposure of man to natural radiation [fr

  4. Remedial activities effectiveness verification in tailing areas.

    Science.gov (United States)

    Kluson, J; Thinova, L; Neznal, M; Svoboda, T

    2015-06-01

    The complex radiological study of the basin of sludge from the uranium ore mining and preprocessing was done. Air kerma rates (including its spectral analysis) at the reference height of 1 m above ground over the whole area were measured and radiation fields mapped during two measuring campaigns (years 2009 and 2014). K, U and Th concentrations in sludge and concentrations in depth profiles (including radon concentration and radon exhalation rates) in selected points were determined using gamma spectrometry for in situ as well as laboratory samples measurement. Results were used for the analysis, design evaluation and verification of the efficiency of the remediation measures. Efficiency of the sludge basin covering by the inert material was modelled using MicroShield code. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  5. Optimized collection, storage and measurement of radon and radon decay products - school experiments

    International Nuclear Information System (INIS)

    Philipsborn, H. von; Geipel, R.; Just, G.

    1998-01-01

    Schools are expected more than ever to teach in physics and chemistry an understanding of radioactivity in its many aspects. Simple experiments on the occurrence, the measurement and the properties of radionuclides are necessary for true understanding. Such experiments are now possible with novel methods of collection and storage of ubiquitous radon and radon decay products from air, water and solids. (orig.) [de

  6. Investigations of radon and radon daughters in surficial aquifers of florida

    International Nuclear Information System (INIS)

    1991-05-01

    The principal purpose of the investigation was to test the hypothesis that radon soil flux, considered the principal source of indoor radon contamination, has an underlying relationship to the radon content of associated shallow groundwaters. The working hypothesis was that radon build-up in both soil and shallow groundwater is basically a consequence of the same factor, radon emanation from soil grains and the solid surfaces of the aquifers. Groundwater may be advantageous as an indicator of radon potential. Another object of the project was to investigate temporal and spatial trends of radon daughter products in shallow aquifers. After analyzing all of the radon soil, flux, and groundwater measurements made over the two-year study period, it is clear that while there is no direct relationship between either radon soil concentration or flux and groundwater radon. Measurements in wells where polonium is present at very high concentrations have shown that 210Po is largely unsupported by its radioactive predecessor, and that polonium is considerably more variable, in both space and time than other parameters measured in the same wells, including radon

  7. Experience from using plastic film in radon measurement

    International Nuclear Information System (INIS)

    Joensson, G.

    1999-01-01

    Plastic film is a useful detector of radon gas. The method of detection of the gas is used for several decades to measure radon concentrations both indoors and in soil. Experiences from radon measurements in Sweden indoors, in soil and in water using the plastic film Kodak LR 115-II are discussed in this report. Some examples are given from various projects. One example is taken from a large scale mapping of indoor radon levels in houses, where the building material is the main source of radon. In another example the measurements from a large scale soil radon mapping are discussed. The use of the plastic film for measurements of radon levels in water is also discussed. All the investigations are made in order to give the authorities concerned information of the radon situation and to study the connection between high indoor radon levels and various types of cancers

  8. Radon dosimetry: a review of radon and radon daughter exposure conditions in dwellings and other structures

    International Nuclear Information System (INIS)

    Ryan, M.T.; Goldsmith, W.A.; Poston, J.W.; Haywood, F.F.; Witherspoon, J.P.

    1983-07-01

    Within the past few years several situations have been brought to light which indicate an increased radiation exposure of certain segments of the general population caused by human activities. The most widely publicized activities are those associated with the mining and milling of uranium in the western United States, the phosphate industry in Florida, and those potential problems represented by former Manhattan Engineer District sites. One of the primary problems involves exposure to radon and radon daughters which are released from large waste piles or, in some cases, evolve from backfill and construction materials used in homes, schools, and other buildings. This report presents a review of the available data on radon and radon daughter concentrations in dwellings and other structures. The primary objectives were to compile and tabulate pertinent radon exposure data and to prepare a statistical summary of the data which will be useful in the prediction of normal levels of radon and radon daughter concentrations in these structures. In addition, other parameters associated with radon exposure conditions are presented and discussed

  9. THE REPUBLIC OF BELARUS RADON DANGER MAP

    Directory of Open Access Journals (Sweden)

    L. A. Chunikhin

    2016-01-01

    Full Text Available Radon is the major contributor to the background exposure of the population. In the world practice, the radon risk or radon potential mapping are used for the radon dose assessment.The aim of this work was a radon danger mapping of the Republic of Belarus to assess the radiation situation and determine the radon hazard critical areas.Materials and methods: The mapping is based on measured values of radon volume activity in the living rooms of different buildings on the territory of the six regions of the Republic of Belarus. We have performed more than 4000 measurements. Integral track radon radiometers based on the polymer Kodak LR-115 film were used to evaluate radon volume activity. Exposure time ranged from 90 to 120 days. The cartogram was built with using the MAPINFO software package.Results: The low levels of radon concentrations were determined in the Brest and Gomel regions, as well as in the southern districts of Minsk and south-western districts of the Mogilev region. The high levels radon concentrations were determined in some districts of the Vitebsk and Grodno regions, as well as in the north-eastern districts of the Mogilev region. About 2–5 times nonuniformity of radon distribution in settlements of the Republic was observed. The radon hazard critical areas with radon concentrations in the range of 200–400 Bq/m3 were found in some districts of the Vitebsk, Grodno and Mogilev regions.Conclusions: The radon risk map of the Republic of Belarus gives the possibility to estimate the existing radiation risk. Taking into account the low efficiency of countermeasures long after the Chernobyl accident, it is necessary to increase the level of radiation protection through the radon mitigation activities or to change the radon normative documents.

  10. Determination of radon in soil and water in parts of Accra, and generation of preliminary radon map for Ghana

    International Nuclear Information System (INIS)

    Osei, Peter

    2016-07-01

    The research was focused on determining the radon levels in soil and water in parts of Accra, generate a preliminary radon map for Ghana and estimate a pilot reference level for the country, using the data obtained from this research and collated data from other researchers. The radon gas measurement was done with the passive method, using the SSNTDs which are sensitive to alpha particles emitted by radon. Cellulose nitrate LR – 115 type II alpha particle detectors were used. The detectors were chemically etched in a 2.5 M NaOH solution at a temperature of 60 °C for 90 minutes, after two weeks and two months of exposure to soil and water respectively. The images of the etched detectors were acquired by means of a scanner and then tracks counted with ImageJ software. Inverse Distance Weighing (IDW) method of ArcGIS 10.2 was used to spatially distribute the radon concentration on a map. The average soil radon concentration in the study area ranges from 0.191 kBqm"-"3 to 3.416 kBqm"-"3 with a mean of 1.193 kBqm"-"3. The radon concentration in water from the study area ranges from 0.00346 BqL"-"1 to 0.00538 BqL"-"1 with an average of 0.00456 BqL"-"1. A strong negative correlation has been established between radon in soil and water in the study area. The preliminary national average indoor, water and soil radon concentrations are 137 Bqm"-"3, 361.93 Bqm"-"3 and 3716.74 Bqm"-"3 respectively. The average levels of water and indoor radon exceeded WHO’s reference level of 100 Bqm"-"3. Accordingly, the pilot national indoor radon reference level for Ghana is set as 200 Bqm"-"3. (au)

  11. Background concentrations of radon and radon daughters in Canadian homes

    International Nuclear Information System (INIS)

    McGregor, R.G.; Vasudev, P.; Letourneau, E.G.; McCullough, R.S.; Prantl, F.A.; Taniguchi, H.

    1980-01-01

    Measurements of radon and radon daughters were carried out in 14 Canadian cities on a total of 9999 homes selected in a statistically random manner. The geometric means of the different cities varied from 0.14 to 0.88 pCi/l. for radon and 0.0009 to 0.0036 Working Levels for radon daughters. The radon originates from natural radioactivity in the soil surrounding the homes. (author)

  12. The radon influence of SAGE results

    International Nuclear Information System (INIS)

    Gavrin, V.N.; Gorbachev, V.V.; Mirmov, I.N.

    2002-01-01

    The method for evaluating systematic errors, connected with radon, is described in the experiment on determining the SAGE solar neutrino flux. The systematic error by the measured neutrino capture rate in the gallium 75 SNU target does not exceed 0.3 SNU. The obtained value (0.3 SNU) is the upper limit of the radon systematic error. Its low value means, that radon does not contribute significantly to the SAGE result [ru

  13. Study of underground radon transport

    International Nuclear Information System (INIS)

    Csige, I.; Hakl, J.; Lenart, L.

    1990-01-01

    The soil gas radon content measurements with solid state nuclear track detectors (SSNTDs) are widely used in geoscience, for instance in uranium exploration and earthquake prediction. In these applications the radon frequently is used as a natural tracer of underground fluid transport processes. Obviously, to get the soil radon measuring method more and more effective the study of these transport processes in deeper part of the Earth is fundamental. The Track Detector Group in the Institute of Nuclear Research of the Hungarian Academy of Sciences in Debrecen has been performing environmental radon activity concentration measurements since 1977 with alpha sensitive SSNTDs. These types of measurements were initiated and widely used by the late head of the group Dr. G. Somogyi, who devoted his life to better understanding of the nature. The measurements in caves, springs and drilled wells proved to be effective to study these underground radon transport processes. We are glad to present some results of our investigations. 7 refs, 7 figs

  14. Radon in public buildings; Radon in oeffentlichen Gebaeuden

    Energy Technology Data Exchange (ETDEWEB)

    Schulz, H.; Flesch, K. [IAF - Radiooekologie GmbH, Dresden (Germany); Hermann, E. [B.P.S. Engineering GmbH, Zwickau (Germany); Loebner, W. [Wismut GmbH, Chemnitz (Germany); Leissring, B. [Bergtechnisches Ingenieurbuero GEOPRAX, Chemnitz (Germany)

    2009-07-01

    From the Free State of Saxony, a study was commissioned to survey how reliable measurements to characterize the radon situation in public buildings at a reasonable financial and human effort can be carried out to reduce radiation exposure in public buildings. The study approach was for 6 objects. To characterize the radon situation the time evolution measurement of radon concentrations of more than 1 to 2 weeks turned out to be sufficient. A novel data analysis enables the identification of a ''typical daily alteration of the radon concentration'' depending on the ventilation conditions and the daily use of the offices or class rooms. The identification of typical diurnal radon variations for the working time and weekends or holidays is of fundamental importance for assessing the exposure situation in public buildings. It was shown that the radon concentration during working time are in general much lower than in the times when the buildings (offices) are unused. It turned out that the long-term radon measurements with nuclear track detectors within distinct time regimes (day / night, working hours / leisure time) by utilizing switch modules are very efficient to estimate the actual exposure. (orig.)

  15. Measurements of radon and chemical elements: Popocatepetl volcano

    International Nuclear Information System (INIS)

    Pena, P.; Segovia, N.; Lopez, B.; Reyes, A.V.; Armienta, M.A.; Valdes, C.; Mena, M.; Seidel, J.L.; Monnin, M.

    2002-01-01

    The Popocatepetl volcano is a higher risk volcano located at 60 Km from Mexico City. Radon measurements on soil in two fixed seasons located in the north slope of volcano were carried out. Moreover the radon content, major chemical elements and tracks in water samples of three springs was studied. The radon of soil was determined with solid detectors of nuclear tracks (DSTN). The radon in subterranean water was evaluated through the liquid scintillation method and it was corroborated with an Alpha Guard equipment. The major chemical elements were determined with conventional chemical methods and the track elements were measured using an Icp-Ms equipment. The radon on soil levels were lower, indicating a moderate diffusion of the gas across the slope of the volcano. The radon in subterranean water shown few changes in relation with the active scene of the volcano. The major chemical elements and tracks showed a stable behavior during the sampling period. (Author)

  16. Behaviors of radon in indoor environment

    International Nuclear Information System (INIS)

    Mochizuki, Sadamu; Shimo, Michikuni.

    1987-01-01

    The source of radon ( 222 Rn) in the atmosphere is radioactive nuclide, uranium ( 238 U), which exists fairly common throughout the earth's crust. Radium ( 226 Ra) descended from uranium produce radon ( 222 Rn) of noble gas by decay. After formation in the ground, radon diffuses into the atmosphere. Without exception radon decay products are heavy metals which soon become attached to natural aerosols. Therefore, radon and its daughters (decay products) appear also in indoor environment, and generally, their concentration levels become higher than that of outdoor air due to build-up effects in the closed indoor environments. With the progress of the study on the influence of radon and its daughers on human health, it has become clear that they act effectively as an exciting cause of lung cancer. So, the study on the risk evaluation of them in room air has become to be very important. Concequently, the behaviors of radon and its daughters in indoor environment, first of all, should be studied in detail for the accurate estimation of the risk caused by them. In this special edition, fundamental characteristics of radon and its daughters, some measuring methods, theoretical considerations and some observational evidences obtained from various circumstances of indoor environment are described inorder to grasp and understand the behaviors of radon and its daughters in the indoor environment. (author)

  17. Two significant experiences related to radon in a high risk area in Spain

    International Nuclear Information System (INIS)

    Sainz, C.; Gutierrez-Villanueva, J.-L.; Fuente, I.; Quindos, L.; Soto, J.; Quindos-Poncela, L.S.; Arteche, J.-L.

    2010-01-01

    Radon is a natural radioactive gas and it is currently accepted as being responsible for lung cancer in some cases. One of the most important sources of indoor radon is from the soil. The RADON content of soil is also a very important factor to be taken into account. The natural radiation map of Spain (MARNA) classifies the country into three regions with different levels of natural gamma radiation. There are some areas in Spain with high levels of natural radiation one of those is the province of Salamanca. Western part of this province presents a population of 20 000 inhabitants and 7% of the houses have an indoor radon concentration above 400 Bq·m -3 . In this high risk area, the village of Villar de la Yegua is of special interest: 11% of the houses in this village have an indoor radon level below 400 Bq·m -3 , 89% have above 400 Bq·m -3 and 71% of the houses have a radon concentration above 1000 Bq·m -3 . An old uranium mine site close to this village has been selected for the construction of an experimental pilot house. It is a two story house located in the place with a very high 226 Ra concentration in soil. Radon in soil at 1 m depth has an average level of 250 kBq·m -3 . We present in this work the characteristics of the experimental unit located in this high risk area and we describe the zone where one of the Spanish villages with the highest radon concentration is located. This is a very interesting place for further research on indoor radon concentration and it is a unique opportunity of testing radon monitors, radon passive detectors and remedial actions for the mitigation of radon in real conditions. It is common to carry out intercomparison exercises under laboratory conditions. Nonetheless, it is not so common to develop these exercises in real conditions as we have in the experimental unit we present here. We offer in this work the possibility for other research groups of testing their equipment in this unit and we also show the evolution of

  18. Development of subsurface characterization method for decommissioning site remediation

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Sang Bum; Nam, Jong Soo; Choi, Yong Suk; Seo, Bum Kyoung; Moon, Jei Kwon; Choi, Jong Won [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    In situ measurement of peak to valley method based on the ratio of counting rate between the full energy peak and Compton region was applied to identify the depth distribution of 137Cs. The In situ measurement and sampling results were applied to evaluate a residual radioactivity before and after remediation in decommissioning KRR site. Spatial analysis based on the Geostatistics method provides a reliable estimating the volume of contaminated soil with a graphical analysis, which was applied to the site characterization in the decommissioning KRR site. The in situ measurement and spatial analysis results for characterization of subsurface contamination are presented. The objective of a remedial action is to reduce risks to human health to acceptable levels by removing the source of contamination. Site characterization of the subsurface contamination is an important factor for planning and implementation of site remediation. Radiological survey and evaluation technology are required to ensure the reliability of the results, and the process must be easily applied during field measurements. In situ gamma-ray spectrometry is a powerful method for site characterization that can be used to identify the depth distribution and quantify radionuclides directly at the measurement site. The in situ measurement and Geostatistics method was applied to the site characterization for remediation and final status survey in decommissioning KRR site.

  19. Radon in indoor air of primary schools: determinant factors, their variability and effective dose.

    Science.gov (United States)

    Madureira, Joana; Paciência, Inês; Rufo, João; Moreira, André; de Oliveira Fernandes, Eduardo; Pereira, Alcides

    2016-04-01

    Radon is a radioactive gas, abundant in granitic areas, such as in the city of Porto at the north-east of Portugal. This gas is a recognized carcinogenic agent, being appointed by the World Health Organization as the leading cause of lung cancer after smoking. The aim of this preliminary survey was to determine indoor radon concentrations in public primary schools, to analyse the main factors influencing their indoor concentration levels and to estimate the effective dose in students and teachers in primary schools. Radon concentrations were measured in 45 classrooms from 13 public primary schools located in Porto, using CR-39 passive radon detectors for about 2-month period. In all schools, radon concentrations ranged from 56 to 889 Bq/m(3) (mean = 197 Bq/m(3)). The results showed that the limit of 100 Bq/m(3) established by WHO IAQ guidelines was exceeded in 92 % of the measurements, as well as 8 % of the measurements exceeded the limit of 400 Bq/m(3) established by the national legislation. Moreover, the mean annual effective dose was calculated as 1.25 mSv/y (ranging between 0.58 and 3.07 mSv/y), which is below the action level (3-10 mSv). The considerable variability of radon concentration observed between and within floors indicates a need to monitor concentrations in several rooms for each floor. A single radon detector for each room can be used, provided that the measurement error is considerably lower than variability of radon concentration between rooms. The results of the present survey will provide useful baseline data for adopting safety measures and dealing effectively with radiation emergencies. In particular, radon remediation techniques should be used in buildings located in the highest radon risk areas of Portugal. The results obtained in the current study concerning radon levels and their variations will be useful to optimize the design of future research surveys.

  20. Measurements of indoor radon and radon progeny in Mexico City

    International Nuclear Information System (INIS)

    Cheng, Y.S.; Rodriguez, G.P.

    1996-01-01

    Indoor radon has been a public concern associated with increased lung cancer risks. Radon decay products interact with indoor aerosols to form progeny with different size distributions, which may influence the lung dosimetry when the progeny are inhaled. Air pollution in Mexico City is a serious problems with high particulate concentrations, but there are few reports of indoor radon measurement. The purposes of this study were to measure the aerosol concentration, radon concentration, and radon activity size distribution in the living area of three houses in Mexico City. The radon concentration was monitored by a RGM-3 radon gas monitor (Eberline, Inc., Santa Fe, NM). A graded diffusion battery was used to determine the progeny concentration and activity size distribution. The concentration and size distribution of the indoor aerosols were monitored by a quartz, crystal microbalance cascade impactor. Our measurements showed high concentrations of indoor aerosols (20-180 gg m -3 ). However, the radon concentrations-were low ( -1 ), but showed a clear diurnal pattern with peak concentrations from 2-10 AM. The activity size distributions of radon progeny were trimodal, with peaks of 0.6 nm, 4-5 nm, and 100 rim. Most activities were associated with large particle sizes. Our results indicated that indoor radon concentration was not high, due in part to a relatively high air exchange with outdoor air. The high aerosol concentration may also play an important part in the activity size distribution of radon progeny

  1. Indoor radon measurements and methodologies in Latin American countries

    International Nuclear Information System (INIS)

    Canoba, A.; Lopez, F.O.; Arnaud, M.I.; Oliveira, A.A.; Neman, R.S.; Hadler, J.C.; Iunes, P.J.; Paulo, S.R.; Osorio, A.M.; Aparecido, R.; Rodriguez, C.; Moreno, V.; Vasquez, R.; Espinosa, G.; Golzarri, J.I.; Martinez, T.; Navarrete, M.; Cabrera, I.; Segovia, N.; Pena, P.; Tamez, E.; Pereyra, P.; Lopez-Herrera, M.E.; Sajo-Bohus, L.

    2001-01-01

    According to the current international guidelines concerning environmental problems, it is necessary to evaluate and to know the indoor radon levels, specially since most of the natural radiation dose to man comes from radon gas and its progeny. Several countries have established National Institutions and National Programs for the study of radon and its connection with lung cancer risk and public health. The aim of this work is to present the indoor radon measurements and the detection methods used for different regions of Latin America (LA) in countries such as Argentina, Brazil, Ecuador, Mexico, Peru and Venezuela. This study shows that the passive radon devices based on alpha particle nuclear track methodology (NTM) is one of the more generalized methods in LA for long term indoor radon measurements, CR-39, LR-115 and Makrofol being the more commonly used detector materials. The participating institutions and the radon level measurements in the different countries are presented in this contribution

  2. Radon and radon daughters in South African underground mines

    International Nuclear Information System (INIS)

    Rolle, R.

    1980-01-01

    Radon and the radon daughters are the radionuclides which primarily determine the level of the radiation hazard in underground uranium mines and to a smaller extent in non-uranium mines. Radon is a gas, and its daughters adsorb on aerosol particles which are of respirable size. The hazard thus arises from the alpha decay of radon and its daughters in contact with lung tissue. Radon is itself part of the uranium decay chain. The major radionuclide, 238 U, decays successively through thirteen shorter-lived radionuclides to 206 Pb. Radon is the only gaseous decay product at room temperature; the other twelve are solids. The main hazard presented by the uranium decay chain is normally determined by the radon concentration because gaseous transport can bring alpha emitters close to sensitive tissue. There is no such transport route for the other alpha emitters, and the level of beta and gamma radiation caused by the uranium decay chain generally presents a far lower external radiation hazard. Radon itself is the heaviest of the noble gases, which are He, Ne, Ar, Kr, Xe and Rn. Its chemical reactions are of no concern in regard to its potential hazard in mines as it may be considered inert. It does, however, have a solubility ten times higher than oxygen in water, and this can play a significant part in assisting the movement of the gas from the rock into airways. Radon continuously emanates into mine workings from uranium ores and from the uranium present at low concentrations in practically any rock. It has been found that the control of the exposure level is most effectively achieved by sound ventilation practices. In South African mines the standard of ventilation is generally high and exposure to radon and radon daughters is at acceptably low levels

  3. Study on indoor radon exposure and its effect on human health

    International Nuclear Information System (INIS)

    Lu Xinwei

    2005-01-01

    Radon and its daughters relate to people health. Radon widely exists in the nature. The paper discusses the source, exposure and activity level of indoor radon, systematically analyzes the hazards and dose-response of residential radon exposure, and at last indicates the concrete method of controlling residential radon concentration. By interdicting radon pollution source and ventilation might effectively reduce indoor radon concentration and improve environmental air quality. (authors)

  4. A study of radon 222 permeation through plastic membranes. Application to a method of radon measurement in water and saturated soils

    International Nuclear Information System (INIS)

    Labed, V.

    1991-04-01

    In order to improve the BARASOL R device and to use it in water-saturated soils and in pressure constraint conditions, we have studied radon 222 permeation through plastic membranes. While the permeation process usually takes place between two media being in the same state, most often gaseous, the present study describes the transfer of radon 222 from the water to the air via a membrane. Polypropylene membranes have been tested with an experimental set-up by monitoring the evolution of radon concentrations in water and in air. The permeation coefficient and the activation energy were calculated in various conditions. With a second experimental set-up, we have tested the polyethylene membrane which has been adapted on the BARASOL. In these conditions, we have shown that it is possible to measure radon in water at concentrations around 10 3 Bq.m -3 [fr

  5. The control of radon levels in houses

    International Nuclear Information System (INIS)

    Al-Jarallah, M. B. I.

    2007-01-01

    The article speaks about radon entry ways to houses, the technologies of controlling the level of radon in indoors and four possible ways to solve the problem of high concentration of radon gas in housing and protection from being gathered to a certain extent that is harmful to health. These methods are: removal of the radon source, modifying the radon source, ventilation and air filtration. The article also addresses the impact of reducing the consumption of heating energy in homes and buildings using thermal insulators in floors, walls, ceilings and doors and making double glazed windows that confine the air. It has been proven that there is a steady relationship between energy conservation measures in housing and the increase of radon concentration by two to three times. In a lot of buildings, where conservation measures have been taken, materials to conserve heat are used, which themselves launch radon and this may lead to increased levels of the gas in the housing.

  6. Radon in the Hotels in Montenegro

    International Nuclear Information System (INIS)

    Vukotic, P.; Antovic, N.; Dapcevic, S.; Uvarov, V.V.; Mrdak, R.

    1997-01-01

    Indoor radon concentrations in the 16 hotels in Montenegro, well known by tourists, were measured in winter period by an integral method, with etch-track detectors. Radon concentrations obtained at the 30 measuring sites are in a range (22 - 90) Bq/m 3 , with an arithmetic mean of 43 Bq/m 3 . This means that the radon levels in the all surveyed hotels in Montenegro are much bellow the most stringent reference level internationally recommended. (author)

  7. Intercomparison of active, passive and continuous instruments for radon and radon progeny measurements in the EML chamber and test facility

    International Nuclear Information System (INIS)

    George, A.C.; Knutson, E.O.; Tu, K.W.; Fisenne, I.M.

    1995-12-01

    The results from the May 1995 Intercomparison of Active, Passive and Continuous Instruments for Radon and Radon Progeny Measurement conducted in the EML radon exposure and test facility are presented. Represented were 13 participants that measure radon with open faced and diffusion barrier activated carbon collectors, 10 with nuclear alpha track detectors, 9 with short-term and long-term electret/ionization chambers, and 13 with active and passive commercial electronic continuous monitors. For radon progeny, there were four participants that came in person to take part in the grab sampling methodology for measuring individual radon progeny and the potential alpha energy concentration (PAEC). There were 11 participants with continuous and integrating commercial electronic instruments that are used for measuring the PAEC. The results indicate that all the tested instruments that measure radon fulfill their intended purpose. All instruments and methods used for grab sampling for radon progeny did very well. However, most of the continuous and integrating electronic instruments used for measuring the PAEC or working level appear to underestimate the potential risk from radon progeny when the concentration of particles onto which the radon progeny are attached is -3

  8. Development of a standard for indoor radon measurements in Australia

    International Nuclear Information System (INIS)

    O'Brien, R.S.; Solomon, S.B.

    1994-01-01

    A standard covering methodologies for the measurement of indoor radon and radon progeny concentrations in air in Australian buildings is currently under preparation as part of a set of standards covering total indoor air quality. This paper outlines the suggested methodology for radon and discusses some of the problems associated with the development of the standard. The draft standard recommends measurement of the radon concentration in air using scintillation cells, charcoal cups and solid state nuclear track detectors, and measurement of radon progeny concentration in air using the Rolle method or the Nazaroff method. 14 refs., 1 tab

  9. Control of radon and its progeny concentration in indoor atmosphere

    International Nuclear Information System (INIS)

    Ramachandran, T.V.; Subbaramu, M.C.

    1986-01-01

    Exposure to radon daughter concentration in indoor atmosphere can result in a significant risk to the general public. There are two generally used methods for the control of radon and progeny concentration in the indoor atmosphere, namely restriction of radon entry and reduction of indoor radon and its progeny concentration by ventilation or by air cleaning. Predominant radon entry process in most of the dwellings appears to be by pressure driven flow of soil gas through cracks or other openings in the basement slab or subfloors. Sealing these openings or ventilation of the subslab or subfloor space are the methods for reducing the radon entry rates. Indoor radon concentration can also be reduced by increasing the ventilation and by using charcoal filters for the removal of radon gas in indoor air by absorption. Concentration of radon progeny, which are responsible for most of the health risks associatd with radon exposure can also be controlled by the use of electrostatic or mechanical filters. This study describes briefly the above control strategies used for reducing the inhalation doses to persons in dwellings. (author). 9 refs., 2 tables

  10. Determination of radon levels in Mexico City; Determinacion de niveles de radon en la Ciudad de Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Pena G, P

    1992-01-15

    The study of the determination of radon levels in the houses room in Mexico City is part of the project Emanometry of the radon. To carry out this study, the passive method was used, which consists of: thin film dosemeter of cellulose nitrate, container of the same one and spark accountant. The method is based on the mensurations of exhibition of the number of marks of alpha track is of the open type and it allows to average the radon activity along several weeks and it presents low concentrations. This study was carried out in 4 periods of exhibition of 3 months each one. (Author)

  11. Indoor Radon Exposure in Italian Schools

    Directory of Open Access Journals (Sweden)

    Antonio Azara

    2018-04-01

    Full Text Available Background: The aim of the study was to assess radon concentration in schoolrooms in a city located in the midwest of Italy. Methods: A two-phase environmental study was carried out in 19 school buildings of 16 primary, secondary, and tertiary schools. Results: Median (interquartile range—IQR indoor radon concentration in schoolrooms was 91.6 (45.0–140.3 Bq/m3. The highest (median 952.8 Bq/m3 radon concentration was found in one (3.6% classroom, located in a building of a primary school whose median concentration was 185 Bq/m3. Radon concentration was significantly correlated with the number of students and teachers, foundation wall construction material, and with the absence of underground floors. A geopedological survey was performed close to the building with highest radon level, showing the presence of granite and tonalithic granodiorite in the soil. Conclusions: Radon levels should be routinely assessed where individuals live or work. Schools are susceptible targets, because of childhood stay and the long daily stay of occupants. Low-cost interventions, such as implementation of natural air ventilation and school maintenance, can reduce radon levels, limiting individual exposure.

  12. Deterministic Chaos in Radon Time Variation

    International Nuclear Information System (INIS)

    Planinic, J.; Vukovic, B.; Radolic, V.; Faj, Z.; Stanic, D.

    2003-01-01

    Radon concentrations were continuously measured outdoors, in living room and basement in 10-minute intervals for a month. The radon time series were analyzed by comparing algorithms to extract phase-space dynamical information. The application of fractal methods enabled to explore the chaotic nature of radon in the atmosphere. The computed fractal dimensions, such as Hurst exponent (H) from the rescaled range analysis, Lyapunov exponent (λ ) and attractor dimension, provided estimates of the degree of chaotic behavior. The obtained low values of the Hurst exponent (0< H<0.5) indicated anti-persistent behavior (non random changes) of the time series, but the positive values of the λ pointed out the grate sensitivity on initial conditions and appearing deterministic chaos by radon time variations. The calculated fractal dimensions of attractors indicated more influencing (meteorological) parameters on radon in the atmosphere. (author)

  13. Radon time variations and deterministic chaos

    Energy Technology Data Exchange (ETDEWEB)

    Planinic, J. E-mail: planinic@pedos.hr; Vukovic, B.; Radolic, V

    2004-07-01

    Radon concentrations were continuously measured outdoors, in the living room and in the basement at 10 min intervals for a month. Radon time series were analyzed by comparing algorithms to extract phase space dynamical information. The application of fractal methods enabled exploration of the chaotic nature of radon in atmosphere. The computed fractal dimensions, such as the Hurst exponent (H) from the rescaled range analysis, Lyapunov exponent ({lambda}) and attractor dimension, provided estimates of the degree of chaotic behavior. The obtained low values of the Hurst exponent (0radon time variations. The calculated fractal dimensions of attractors indicated more influencing (meteorological) parameters on radon in the atmosphere.

  14. Radon time variations and deterministic chaos

    International Nuclear Information System (INIS)

    Planinic, J.; Vukovic, B.; Radolic, V.

    2004-01-01

    Radon concentrations were continuously measured outdoors, in the living room and in the basement at 10 min intervals for a month. Radon time series were analyzed by comparing algorithms to extract phase space dynamical information. The application of fractal methods enabled exploration of the chaotic nature of radon in atmosphere. The computed fractal dimensions, such as the Hurst exponent (H) from the rescaled range analysis, Lyapunov exponent (λ) and attractor dimension, provided estimates of the degree of chaotic behavior. The obtained low values of the Hurst exponent (0< H<0.5) indicated anti-persistent behavior (non-random changes) of the time series, but the positive values of λ pointed out the grate sensitivity on initial conditions and the deterministic chaos that appeared due to radon time variations. The calculated fractal dimensions of attractors indicated more influencing (meteorological) parameters on radon in the atmosphere

  15. Distribution of indoor radon concentrations and elements of a strategy for control

    International Nuclear Information System (INIS)

    Nero, A.V. Jr.

    1986-05-01

    Indoor radon concentrations vary widely in the US housing stock, with normal concentrations estimated to cause a significant risk of lung cancer by comparison with environmental exposures normally considered, and high concentrations causing risks that exceed even those from cigarette smoking. The probability distribution, i.e., the number of houses at various concentrations, can be estimated from an analysis of the US indoor radon data accumulated to date. Such an analysis suggests that in about a million houses, occupants are receiving exposures greater than those experienced by uranium miners. The form of the frequency distribution, including not only the average concentration, but also the number of houses with high levels, has substantial influence on strategies for control of indoor radon. Such strategies require three major elements: formulation of control objectives in terms of guidelines for remedial action and for new houses; selection of means for identifying homes with high concentrations; and a framework for deciding what types of control measures are appropriate to particular circumstances and how rapidly they should be employed

  16. New method and installation for rapid determination of radon diffusion coefficient in various materials.

    Science.gov (United States)

    Tsapalov, Andrey; Gulabyants, Loren; Livshits, Mihail; Kovler, Konstantin

    2014-04-01

    The mathematical apparatus and the experimental installation for the rapid determination of radon diffusion coefficient in various materials are developed. The single test lasts not longer than 18 h and allows testing numerous materials, such as gaseous and liquid media, as well as soil, concrete and radon-proof membranes, in which diffusion coefficient of radon may vary in an extremely wide range, from 1·10(-12) to 5·10(-5) m(2)/s. The uncertainty of radon diffusion coefficient estimation depends on the permeability of the sample and varies from about 5% (for the most permeable materials) to 40% (for less permeable materials, such as radon-proof membranes). Copyright © 2014. Published by Elsevier Ltd.

  17. Indoor radon

    International Nuclear Information System (INIS)

    1997-12-01

    The radon, a natural radioactive gas, is present almost everywhere on the earth's surface. It can be accumulated at high concentration in confined spaces (buildings, mines, etc). In the last decades many studies conducted in several countries showed that inhaling important amounts of radon rises the risk of lung cancer. Although, the radon is a naturally appearing radioactive source, it may be the subject of a human 'enhancement' of concentration. The increasing radon concentration in professional housing constitutes an example of enhanced natural radioactivity which can induce health risks on workers and public. Besides, the radon is present in the dwelling houses (the domestic radon). On 13 May 1996, the European Union Council issued the new EURATOM Instruction that establishes the basic standards of health protection of population and workers against the ionizing radiation hazards (Instruction 96/29/EURATOM, JOCE L-159 of 29 June 1996). This instruction does not apply to domestic radon but it is taken into consideration by another EURATOM document: the recommendation of the Commission 90/143/EURATOM of 21 February 1990 (JOCE L-80 of 27 March 1990). The present paper aims at establishing in accordance to European Union provisions the guidelines for radon risk management in working places, as well as in dwelling houses, where the implied risk is taken into account. This document does not deal with cases of high radon concentration on sites where fabrication, handling or storage of radium sources take place. These situations must be treated by special studies

  18. Indoor radon II

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    Because of the growing interest in and public concern about indoor radon, APCA, in April 1987, sponsored the Second International Specialty Conference on Indoor Radon. This book is the proceedings of this conference and includes discussions on: A current assessment of the nature of the problem; Issues related to health effects and risk assessment; The development of public and private sector initiatives; Research into methods of control and prevention; International perspectives; and Measurement methods and programs. The material is intended for the technically oriented and for those responsible for developing programs and initiatives to address this important public health issue. Contributors include federal, state, and provincial program officials and members of the academic and private sectors

  19. Mechanisms of radon injury

    International Nuclear Information System (INIS)

    Cross, F.T.

    1988-01-01

    In this new project, they conduct molecular, cellular and whole-animal research relevant to understanding the inhalation toxicology of radon and radon-daughter exposures. The work specifically addresses the exposure-rate effect in radon-daughter carcinogenesis; the induction-promotion relationships associated with exposure to radon and cigarette-smoke mixtures; the role of oncogenes in radon-induced cancers; the effects of radon on DNA as well as on DNA repair processes; and the involvement of growth factors and their receptors in radon-induced carcinogenesis. Preliminary experiments showed that oncogenes are activated in radon-induced lung tumors. They have therefore begun further exposures pertinent to the oncogene and growth-factor studies. An in vitro radon cellular-exposure system was designed, and cell exposures were initiated. Initiation-promotion-initiation studies with radon and cigarette-smoke mixtures have also begun; and they are compiling a radon health-effects bibliography

  20. Developing a method for the retrospective estimation of radon exposure from in vivo measurements of 210Pb activity in bone

    International Nuclear Information System (INIS)

    McKenzie, R.J.; Johnston, P.N.

    1999-01-01

    Radon is a naturally occurring radioactive gas which has been linked to lung cancer in occupationally exposed uranium mine workers. Where monitoring of an individual's exposure to radon and radon progeny has not occurred or is incomplete, it may be possible to determine this exposure retrospectively by the measurement of the long lived decay product 210 Pb which accumulates in the bones of exposed individuals. This paper describes a method being developed at the whole body monitor (WBM) facility of the Australian Radiation Protection and Nuclear Safety Agency (ARPANSA) to estimate the time integrated exposure to radon over a period of up to several decades from the in vivo measurements of 210 Pb activity in the knee of human subjects. Initial work has concentrated on characterising the WBM facility for this work using artificial bone phantoms. This project will serve as a test of the feasibility of the method before undertaking further studies on human subjects

  1. Design Criteria for Achieving Low Radon Concentration Indoors

    DEFF Research Database (Denmark)

    Rasmussen, Torben Valdbjørn

    2016-01-01

    Design criteria for achieving low radon concentration indoors are presented in this paper. The paper suggests three design criteria. These criteria have to be considered at the early stage of the building design phase to meet the latest recommendations from the World Health Organization in most...... countries. The three design criteria are; first, establishing a radon barrier facing the ground; second, lowering the air pressure in the lower zone of the slab on ground facing downwards; third, diluting the indoor air with outdoor air. Three criteria when used can prevent radon infiltration and lower...... the radon concentration in the indoor air. In addition, a cheap and reliable method for measuring the radon concentration in the air indoors is described. The provision on radon in the Danish Building Regulations complies with the latest recommendations from the World Health Organization. Radon can cause...

  2. Radon in air calibration procedure: A primary method

    International Nuclear Information System (INIS)

    Lucas, H.F.; Markun, F.

    1988-01-01

    A procedure has been developed for preparing 3- to 9-iota volumes of air under natural conditions with a known concentration of /sup 222/Rn to be used for calibrating radon systems. Air is passed into a plastic bag through a standard /sup 226/Ra solution (prepared by the U.S. National Bureau of Standards) contained in an emanation flask. This plastic bag retains /sup 222/Rn with little loss into or through the bag walls. The mean ratios of the /sup 222/Rn in the air at 2 and 7 days after filling to that immediately after filling were -.992 +- 0.006 and 0.969 +- 0.008, which suggests a rate of radon loss into the bag of 0.4 +- 0.1%/day

  3. Analysis of soil radon data in earthquake precursory studies

    Directory of Open Access Journals (Sweden)

    Hari Prasad Jaishi

    2014-10-01

    Full Text Available Soil radon data were recorded at two selected sites along Mat fault in Mizoram (India, which lies in the highest seismic zone in India. The study was carried out during July 2011 to May 2013 using LR-115 Type II films. Precursory changes in radon concentration were observed prior to some earthquakes that occurred around the measuring sites. Positive correlation was found between the measured radon data and the seismic activity in the region. Statistical analysis of the radon data together with the meteorological parameters was done using Multiple Regression Method. Results obtained show that the method employed was useful for removing the effect of meteorological parameters and to identify radon maxima possibly caused by seismic activity.

  4. Statistical aspects of autoregressive-moving average models in the assessment of radon mitigation

    International Nuclear Information System (INIS)

    Dunn, J.E.; Henschel, D.B.

    1989-01-01

    Radon values, as reflected by hourly scintillation counts, seem dominated by major, pseudo-periodic, random fluctuations. This methodological paper reports a moderate degree of success in modeling these data using relatively simple autoregressive-moving average models to assess the effectiveness of radon mitigation techniques in existing housing. While accounting for the natural correlation of successive observations, familiar summary statistics such as steady state estimates, standard errors, confidence limits, and tests of hypothesis are produced. The Box-Jenkins approach is used throughout. In particular, intervention analysis provides an objective means of assessing the effectiveness of an active mitigation measure, such as a fan off/on cycle. Occasionally, failure to declare a significant intervention has suggested a means of remedial action in the data collection procedure

  5. Construction of radon/radon daughter calibraton chamber

    International Nuclear Information System (INIS)

    Fry, J.; Gan, T.H.; Leach, V.A.; Saddlier, J.; Solomon, S.B.; Tam, K.K.; Travis, E.; Wykes, P.

    1983-01-01

    The radon/radon daughter test chamber is a copper lined room 1.65x1.75x2.75m with an effective volume of 8000 litres. The air residence time is controlled by circulating the air in the chamber through absolute filters which remove 99.9% of particulates. Radon is drawn into the chamber from a 17 μCi 226 RaCl source using the pressure differential across the blowers (<3 psi)

  6. Application of single-chip microcomputer to portable radon and radon daughters monitor

    International Nuclear Information System (INIS)

    Meng Yecheng; Huang Zhanyun; She Chengye

    1992-01-01

    Application of single-chip microcomputer to portable radon and radon daughters monitor is introduced in this paper. With the single-chip microcomputer automation comes into effect in the process from sampling to measuring of radon and radon daughters. The concentrations of radon and radon daughters can be easily shown when the conversion coefficients are pre-settled before the measurement. Moreover, the principle and design are briefly discussed according to the characteristics of the monitor

  7. Compact detector for radon and radon daughter products

    International Nuclear Information System (INIS)

    Alter, H.W.; Oswald, R.A.

    1986-01-01

    This invention provides an improved compact track registration detector for radon gas. The detector comprises a housing having an open mouth, a bottom, and side walls; track registration means, supported inside the housing, which forms damage tracks along paths traversed by alpha particles; a microporous filter positioned across the mouth of the housing to prevent entry of radon daughters and particulate matter; and a cap that may be placed on the mouth of the housing to retain the filter. The housing has internal wall surfaces dimensioned to optimize the registration of alpha particles from radon and radon daughters present in the housing

  8. The use of soil gas as radon source in radon chambers

    International Nuclear Information System (INIS)

    Al-Azmi, Darwish

    2009-01-01

    A procedure is described in which soil gas is utilized as an alternative to the 226 Ra source for the supply of the radon gas required to fill a radon chamber where radon-measuring devices are calibrated. The procedure offers opportunities to vary the radon concentration within the chamber around an average value of about 500 Bq/m 3 , which is considered to be sufficient for calibrating indoor radon detectors. The procedure is simple and the radon source does not require radiation protection certification (for import and/or use), unlike the commercially produced standard radioactive ( 226 Ra) sources.

  9. Radon pollution in tunnel and protection from the radiation

    International Nuclear Information System (INIS)

    Wang Yanzhao; Shang Aiguo; Guo Huiping

    2004-01-01

    Objective: Study on radon pollution in tunnel and its protection from the radiation. Methods: Analysis the source of radon was analysed and some measures were have been taken to reduce the radon and limit the work hour in the tunnel. Results: The calculating formula of ventilation time and upper limit of working hour in a year are given. Conclusion: By adopting some measures to reduce radon and limiting the upper working hour in a year, the harm of radon to human can be avoid completely. (authors)

  10. Radon in Antarctica

    International Nuclear Information System (INIS)

    Ilic, R.; Rusov, V.D.; Pavlovych, V.N.; Vaschenko, V.M.; Hanzic, L.; Bondarchuk, Y.A.

    2005-01-01

    The paper reviews results of radon measurements obtained in Antarctic research stations in the last 40 years by both active and passive radon monitors. A brief description of the radon laboratory set-up in the Ukrainian Academician Vernadsky station on the Antarctic Peninsula (W 64 o 16 ' , S 65 o 15 ' ), where radon is measured by two types of etched track Rn dosimeter and 4 types of continuous radon monitoring devices is presented. Some selected results of research work are described related to: (i) analysis of radon storms, defined as an abrupt increase of 222 Rn during the occurrence of a cyclone, and its applicability for the study of the transport of air masses of continental origin to Antarctica; (ii) a study of the correlation of changes of radon concentration and geomagnetic field induced by tectonic activity and its application to predicting tectonomagnetic anomalies, and (iii) verification of a newly developed theoretical model based on noise analysis of the measured radon signal for earthquake prediction. Suggestions for future utilization of radon for basic research in Antarctica (and not only in Antarctica) conclude the contribution. conclude the contribution

  11. Air radon equilibrium factor measurement in a Waste Water Pre-Treatment Plant

    International Nuclear Information System (INIS)

    Martinez, J.E.; Juste, B.; Ortiz, J.; Martorell, S.; Verdu, G.

    2017-01-01

    We analyze in this paper a Waste Water Pre-Treatment Plant (WWTP) located at the Mediterranean coast with air radon concentration above Spanish action level (600 Bq per cubic meter). This paper presents a method for radon equilibrium determination by gamma spectrometry measuring of the radon progeny concentrations in the air, in order to estimate WWTP workers effective dose more exactly. The method is based on simultaneous sampling of air through a filter paper and alpha spectrometry measurement of radon activity concentration in the air. According to the measured radon activity concentration in the air of 368±45 Bq/m 3 the equilibrium factor between radon and progenies is estimated to be F=0.27, which is in good agreement with expected values. - Highlights: • High levels of Radon in a workplace can increase health risks in the employees. • Using the typical equilibrium factor 0.4 could lead to an error in the estimation of radon doses. • We present a method for radon equilibrium determination. • Equilibrium factor is calculated by gamma spectrometry measuring of radon progeny concentrations in the air.

  12. Reduction of radon from household water supplies

    International Nuclear Information System (INIS)

    Shapiro, P.S.; Sorg, T.J.

    1988-01-01

    Groundwater can be a major source of indoor radon in homes that use individual wells or are served by very small community water supply systems. In the United States, several wells have been found to contain more than 37,000,000 Bq.m -3 of radon dissolved in the water. This radon can be released in the indoor air in the course of using water for normal household activities. A measurement of the radon in the drinking water can be made when an indoor radon problem is suspected. While ventilation may reduce indoor radon levels that result from household water usage, the most common control technique presently applied is removing the radon from the water using a granular activated carbon (GAC) treatment system. Aeration methods are also effective and have been proven to be economical for small community water supplies. Some of the issues faced in using GAC are sizing and maintaining the unit and shielding and disposing of the GAC to prevent exposure from gamma radiation. (author)

  13. Superfund Record of Decision (EPA Region 2): Glen Ridge Radium, NJ. (First Remedial Action), June 1989

    International Nuclear Information System (INIS)

    1989-01-01

    The Glen Ridge Radium site is in the Borough of Glen Ridge and the town of East Orange in Essex County, New Jersey. The soil at the site is contaminated to varying degrees with radioactive waste materials suspected to have originated from radium processing or utilization facilities located nearby during the early 1900s. Temporary radon ventilation systems and gamma-radiation shielding have been installed and maintained by EPA and the State to reduce indoor exposures. The primary contaminant of concern affecting the soil and structures in radium 226 which delays to radon gas. The selected remedial action includes excavation of approximately 41,000 cu yd of highly contaminated soil and an unspecified amount of debris followed by offsite disposal; installation and maintenance of indoor engineering controls at less contaminated properties; environmental monitoring to ensure remedy effectiveness; and continuation of a treatment technology study for future actions

  14. Radon Survey in Kalamata (Greece)

    International Nuclear Information System (INIS)

    Geranios, A.; Kakoulidou, M.; Mavroidi, Ph.; Moschou, M.; Fisher, S.; Burian, I.; Holecek, J.

    2001-01-01

    A national radon survey is still lacking for Greece. Some groups have carried out several more or less local or extended radon surveys and valuable experience has been gained. After the first preliminary survey carried out by our group, where 500 Kodak LR-115 etched track detectors were placed in Greek schools and dwellings for one year, indoor radon measurements were continued by placing the same number of detectors in a restricted area, covering the city of Kalamata (a medium size city with 60,000 inhabitants), situated in the south of Peloponnese. Although Kalamata was not of special radon interest, the local authorities insisted on knowing for their citizens' sake the level of this natural radiation. At first, the intention was to use a different method of organisation and distribution of the etched-track detectors from the previous one, attempting mainly to acquire more reliable results and to collect as many detectors as possible. Secondly, it was of great importance to test the statistics of the indoor radon concentrations for a rather small area, and thirdly, to estimate independently the annual absorbed dose by children, taking into account radon concentrations measured both in their home and at school. The set of detectors' readings (about 370), revealed, in general, lower values for Kalamata, compared to the ones found in the preliminary radon survey in Greece and almost all concentrations were found to be below the NRPB action level (200 Bq.m -3 ) (author)

  15. Study of radon transport through concrete modified with silica fume

    International Nuclear Information System (INIS)

    Chauhan, R.P.; Kumar, Amit

    2013-01-01

    The concentration of radon in soil usually varies between a few kBq/m 3 and tens or hundreds of kBq/m 3 depending upon the geographical region. This causes the transport of radon from the soil to indoor environments by diffusion and advection through the pore space of concrete. To reduce indoor radon levels, the use of concrete with low porosity and a low radon diffusion coefficient is recommended. A method of reducing the radon diffusion coefficient through concrete and hence the indoor radon concentration by using silica fume to replace an optimum level of cement was studied. The diffusion coefficient of the concrete was reduced from (1.63 ± 0.3) × 10 −7 to (0.65 ± 0.01) × 10 −8 m 2 /s using 30% substitution of cement with silica fume. The compressive strength of the concrete increased as the silica-fume content increased, while radon exhalation rate and porosity of the concrete decreased. This study suggests a cost-effective method of reducing indoor radon levels. -- Highlights: • Radon diffusion study through silica fume modified concrete was carried out. • Radon diffusion coefficient of concrete decreased with increase of silica fume contents. • Compressive strength increased with increase of silica fume. • Radon exhalation rates and porosity of samples decreased with addition of silica fume. • Radon diffusion coefficient decreased to 2.6% by 30% silica fume substitution

  16. Monitoring a chemical plume remediation via the radio imaging method

    International Nuclear Information System (INIS)

    McCorkle, R.W.; Spence, T.; Linder, K.E.; Betsill, J.D.

    1996-01-01

    In this paper, the authors present the results of a site characterization, monitoring, and remediation effort at Sandia National Laboratories (SNL). The primary objective of the study is to determine the feasibility of using the Radio Imaging Method (RIM) to solve a near-surface waste site characterization problem. The goals are to demonstrate the method during the site characterization phase, then continue with an in-situ monitoring and analysis of the remediation process

  17. Radon concentration as an indicator of the indoor air quality: development of an efficient measurement method

    International Nuclear Information System (INIS)

    Roessler, F.A.

    2015-01-01

    Document available in abstract form only. Full text of publication follows: Energy conservation regulation could lead to a reduction of the air exchange rate and also a degradation of the indoor air quality. Present methods for the estimating the indoor air quality can only be implemented with limitations. This paper presents a method that allows the estimation of the indoor air quality under normal conditions by using natural radon as an indicator. With mathematical models, the progression of the air exchange rate is estimated by using the radon concentration. Furthermore, the progression of individual air pollutants is estimated. Through series of experiments in a measurement chamber, the modelling could be verified. (author)

  18. Measured radon inside housings the Republic Argentina

    International Nuclear Information System (INIS)

    Canoba, A.; Arnaud, M.; Lopez, F.; Oliveira, A.A.

    1998-01-01

    They have been measured the radon concentration in houses in different city's in Argentina Republic. For they were used it as method mensuration detectors appearances nuclear detecting electrets and detectors based on the adsorption radon in activated carbon

  19. Distribution of indoor radon levels in Mexico

    CERN Document Server

    Espinosa, G; Rickards, J; Gammage, R B

    1999-01-01

    Our laboratory has carried out a systematic monitoring and evaluation of indoor radon concentration levels in Mexico for ten years. The results of the distribution of indoor radon levels for practically the entire country are presented, together with information on geological characteristics, population density, socioeconomic levels of the population, and architectural styles of housing. The measurements of the radon levels were made using the passive method of nuclear tracks in solids with the end-cup system. CR-39 was used as the detector material in combination with a one-step chemical etching procedure and an automatic digital- image counting system. Wherever a high level was measured, a confirming measurement was made using a dynamic method. The results are important for future health studies, including the eventual establishment of patterns for indoor radon concentration, as it has been done in the USA and Europe.

  20. Meeting new challenges in radon measurements service with solid state alpha track analysis

    International Nuclear Information System (INIS)

    Calamosca, M.; Penzo, S.; Mustapha, A.O.

    2005-01-01

    Full text: The national and international legislation on the control of exposures to radiation now covers exposures to the naturally occurring radioactive materials (NORM), with particular emphasis on radon in workplaces. Consequently, many more working environments have now been brought to the realm of radiation monitoring. This is mirrored by a corresponding increase in the demands for radon monitoring service. The new challenges occasioned by the increase in demands are illustrated in this paper. The paper also describes the new integrated radon measurement system at the ENEA ION-IRP radon-in-air testing laboratory, designed to meet the new challenges. In this presentation emphasis is laid only on the special features, hardware and software, of the measurement system that directly result in enhancement of the overall throughput and the quality of the radon service. In addition the use of a new technique based on a numerical filtering of the main physical parameters of the alpha track analysis used to determine the radon exposure with a CR-39 detector is presented, with particular emphasis to the quality improvements of the measurement. The readout procedure adopted by the Enea radon Service is based on track analysis by light microscopy. Since the dimensions of the tracks are significantly affected by the light intensity, the illumination of the field of view (FOV) has to be as homogeneous as possible, in order to avoid sensitivity dependence on track position in the FOV. The lighting variation could be severe, especially at the borders or when a rectangular FOV is used. The coefficient of variation of the FOV light uniformity has to be periodically checked to maintain the variation below an acceptable limit, whereas if the results exceed this value a remedial action is mandatory. The numerical correction procedure here presented results effective. (author)

  1. Instruments to measure radon activity concentration or exposure to radon. Interlaboratory comparison 2011

    International Nuclear Information System (INIS)

    Foerster, Elisabeth; Beck, Thomas; Buchroeder, Helmut; Doering, Joachim; Schmidt, Volkmar

    2011-10-01

    According to the Directive 96/29/EURATOM the monitoring of occupational radiation exposures shall base on individual measurements carried out by an approved dosimetric service. Pursuant to the European Directive an approved dosimetric service is a body responsible for the calibration, reading or interpretation of individual monitoring devices.., whose capacity to act in this respect is recognized by the competent authorities. This concept will also be applied to radon services issuing passive radon measurement devices. Passive radon measurement devices 1 using solid state nuclear track detectors or electrets are recommended for individual monitoring of exposures to radon. German regulations lay down that radon measuring devices are appropriate for purposes of occupational radiation monitoring if the devices are issued by recognized radon measurement services, and the measurement service submits devices of the same type issued for radon monitoring to regular intercomparisons conducted by BfS. A radon measuring service is recognized by the competent authority if it proves its organizational and technical competence, e. g. by accreditation. These regulations have been introduced in the area of occupational radiation exposures. Nevertheless, it is recommended that radon measuring services which carry out radon measurements in other areas (e.g. dwellings) should subject themselves to these measures voluntarily. The interlaboratory comparisons comprise the organization, exposure, and evaluation of measurements of radon activity concentration or exposure to radon. The comparisons only concern radon-222; radon-220 is not in the scope. Radon services being interested can get further information from the website www.bfs.de/de/ion/radon/fachinfomessung/vergleichspruefungen.html and from the European Information System on Proficiency Testing Schemes (eptis) available in the internet. (orig.)

  2. Attempt to determine radon entry rate and air exchange rate variable in time from the time course of indoor radon concentration

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, J [State Office for Nuclear Protection, Prague (Czech Republic)

    1996-12-31

    For radon diagnosis in houses the `ventilation experiment` was used as a standard method. After removal of indoor radon by draught the build-up of radon concentration a(t) [Bq/m{sup 3}] was measured continuously and from the time course the constant radon entry rate A [Bq/h] and the exchange rate k [h{sup -1}] was calculated by regression analysis using model relation a(t) A(1-e{sup -kt})/kV with V [m{sup 3}] for volume of the room. The conditions have to be stable for several hours so that the assumption of constant A and k was justified. During the day both quantities were independently (?) changing, therefore a method to determine variable entry rate A(t) and exchange rate k(t) is needed for a better understanding of the variability of the indoor radon concentration. Two approaches are given for the determination of variable in time radon entry rates and air exchange rates from continuously measured indoor radon concentration - numerical solution of the equivalent difference equations in deterministic or statistic form. The approaches are not always successful. Failures giving a right ration for the searched rates but not of the rates them self could not be explained.

  3. The Radon from environment to man

    International Nuclear Information System (INIS)

    Metivier, H.; Robe, M.Ch.

    1998-01-01

    The radon inhalation is the principal source of populations irradiation. At the dawn of a new regulation, the best specialists of the radon in France, give the different properties of this gas in order to allow to the non advertised populations to appreciate the risks. This work explains the origin, the formation of this radioactive gas, how is it detected, its behaviour in atmosphere and habitations. A cartography of the radon concentration is given where it is possible to see the differences between the regions. The question of risks is also approached even if it difficult to estimate because it comes from extrapolation. Finally, the reader will find simple methods to reduce irradiation by radon in our habitations. (N.C.)

  4. Factors affecting passive monitoring of radon

    International Nuclear Information System (INIS)

    Asano, Tomohiro; Kahn, B.

    1989-09-01

    In recent years, increasing cancer has been expressed as a possible health hazards associated with long-term exposures to a large population at a low level of radon in the environment. Because radon is ubiquitous nuclide, nation-wide monitoring is necessary to determine lung cancer risk. For such purpose, passive sampling methods with track etch detector or charcoal adsorption collector may have the advantage in lower cost and convenience. The charcoal adsorption collector is considered in this study. Various factors may significantly affect the charcoal adsorption mechanism on its practical application. Moisture effects are discussed here as having major impact on radon collection by charcoal. Set of equations are presented in this report to describe adsorption of radon including moisture effects. (author) 61 refs

  5. Uranium and radon surveys in western Himalaya

    International Nuclear Information System (INIS)

    Virk, H.S.

    1997-01-01

    The water samples from mountain springs, streams and river systems in the western Himalaya were collected and analysed in the laboratory for uranium and radon contents. It is observed that the Himalayan river system is conspicuous by its high dissolved uranium and radium concentration. The water samples contain from 0.89 ppb to 63.4 ppb of uranium and from 34 Bq/I to 364 Bq/I of radon. The radon emanation in soil is measured by the track-etch method, emanometry and alpha-logger technique. The daily and long-term variation of radon was monitored in some mineralized zones of Himachal Pradesh (HP) state with high uranium content in the soil. The maximum values of radon are recorded in Chhinjra, Rameda, Samurkala and Kasol areas of HP. (author)

  6. Radon in buildings: instrumentation of an experimental house

    International Nuclear Information System (INIS)

    Ameon, R.; Diez, O.; Dupuis, M.; Merle-Szeremeta, A.

    2004-01-01

    IRSN decided to develop a code called RADON 2 for conducting simple and methodical studies of indoor radon concentrations. Since a validity check must be performed of the phenomenological model on which the code is based, an experimental program was initiated in 2002, within which a house in Brittany, located on a well-characterized uranium-bearing geological formation, was fitted with special instruments. After characterizing the soil underlying the house, the instrumentation implemented on site continuously monitors a number of parameters to characterize: the radon source term in the building (exhalation rate of 222 Rn at the ground/building interface and at soil surface, radon concentration in the soil and in outdoor air); radon penetration by advection (differential pressure in the house basement); the driving mechanisms for natural ventilation in the house (weather conditions, indoor temperature and relative humidity); radon distribution throughout the house by air flow and radon diffusion (indoor radon concentration at each floor of the house). Using the experimental data acquired over the past two years, the phenomena governing radon penetration inside the house (wind and stack effect) and radon extraction (fresh air supply rate) have been characterized to lay down the bases for validating the newly developed code

  7. Intercomparison of different instruments that measure radon concentration in air

    International Nuclear Information System (INIS)

    Shimo, M.; Iida, T.; Ikebe, Y.

    1987-01-01

    An intercomparison of different instruments for measurement of radon concentration was carried out. The instruments include an ionization chamber, the charcoal-trap technique, a flow-type ionization chamber (pulse-counting technique), a two-filter method, an electrostatic collection method and a passive integrating radon monitor. All instruments except for the passive radon monitor have been calibrated independently. Measurements were performed over a concentration range from about 3.5 Bq/m/sup 3/ (in outdoor air) to 110 Bq/m/sup 3/ (in indoor air). The results obtained from these techniques, except the two-filter technique, are comparable. Radon daughter concentration measured using a filter-sampling technique was about 52% of radon concentrations

  8. Health hazards due to radon and its daughters

    International Nuclear Information System (INIS)

    Khan, H.A.; Qureshi, I.E.; Tufail, M.

    1993-01-01

    The health hazards liked to radon and its daughters have become a matter of great public concern. When inhaled, a fraction of radon is dissolved into the lung fluid, from where it is transported to other parts of the body. The radiation damage is caused to the lungs due to alpha decay of radon during its transit time within the respiratory tract. Radon daughters are found to be even more dangerous than radon itself. These daughters attach themselves to dust particles present in the air. Some of the aerosols so produced enter the lungs and enter the blood stream. It has now been confirmed that radon and its daughters contribute about 70% of the internal dose received by an individual from natural radiation sources. The danger of indoor radon and its daughters is even higher for energy-saving houses and those having poor ventilation systems. This paper briefly describes the health hazards due to radon and its daughters. Different methods employed for the measurement of concentrations of radon and their daughters are described. The experience gained from the nation-wide surveys carried out in different countries is also given. (author). 18 refs, 3 figs, 1 tab

  9. Glass implanted 210Po as a method of determination of long term exposure to radon: First experiments in Israel

    International Nuclear Information System (INIS)

    Haquin, G.; Lang, B.; Even, O.; Asael, Y.; Shamai, Y.; Margaliot, M.; Shirav, M.

    2002-01-01

    Radon gas ( 222 Rn) is known to be the major contributor of the total exposure of the population to ionizing radiation. Retrospective assessment techniques have been developed to estimate long term exposures to ( 222 Rn and its progeny in epidemiological studies. Measurements of implanted 210 Po on glass panes surfaces characterize room radon concentration or habitant characterization.Various methods for retrospective radon measurement are described in the literature. The surface trap method is based on the 210 Po implanted on glass or other vitreous objects, measured using solid-state nuclear track detectors (SSNTD). The volume trap method is based on measurements of 210 Po in spongy, porous materials ( 210 Po volume traps). Other approach is in-vivo measurements of 210 Pb in the human skeleton. The present study uses the surface trap retrospective technique for the first time in Israel, coupled with an approach to estimate the 210 Po concentration in glasses exposed to 222 Rn using alpha spectrometry

  10. Radon emanation from soils

    International Nuclear Information System (INIS)

    Markkanen, M.; Arvela, H.

    1992-01-01

    The results of gamma spectrometric sample measurements of radon ( 222 Rn) emanation coefficients and radium concentrations ( 226 Ra) from about 800 Finnish soil samples are presented. The radon emanation rate was measured in about 400 soil samples, using radon-tight cans and Lucas cells. The effects of water content and temperature on radon emanation were investigated, using various samples of different soil types. Radon emanation and the effect of water content on radon emanation were investigated separately for different grain sizes (samples of till). The results provide some information on radon emanation in different soil types and relate emanation in laboratory conditions to conditions in ground soil. In routine measurements of radon emanation from soil samples, use of a 5% water content was considered advisable. The correction coefficients of radon emanation varied between 0.3 and 1.5, depending on the water content and soil type. At 5% water content, hardly any difference was found between radon emanation at temperatures of 20 and 1 o C. Radon emanation was found to be an inverse function of grain sizes larger than 0.5 mm in diameter. (author)

  11. Radon exhalation rates of some granites used in Serbia

    Directory of Open Access Journals (Sweden)

    Nikolić Mladen D.

    2015-01-01

    Full Text Available In order to address concern about radon exhalation in building material, radon exhalation rate was determined for different granites available on Serbian market. Radon exhalation rate, along with mass exhalation rate and effective radium content were determined by closed chamber method and active continuous radon measurement technique. For this research, special chambers were made and tested for back diffusion and leakage, and the radon concentrations measured were included in the calculation of radon exhalation. The radon exhalation rate ranged from 0.161 Bq/m2h to 0.576 Bq/m2h, the mass exhalation rate from 0.167 Bq/kgh to 0.678 Bq/kgh, while the effective radium content was found to be from 12.37 Bq/kg to 50.23 Bq/kg. The results indicate that the granites used in Serbia have a low level of radon exhalation.

  12. Radon anomalies along faults in North of Jordan

    International Nuclear Information System (INIS)

    Al-Tamimi, M.H.; Abumurad, K.M.

    2001-01-01

    Radon emanation was sampled in five locations in a limestone quarry area using SSNTDs CR-39. Radon levels in the soil air at four different well-known traceable fault planes were measured along a traverse line perpendicular to each of these faults. Radon levels at the fault were higher by a factor of 3-10 than away from the faults. However, some sites have broader shoulders than the others. The method was applied along a fifth inferred fault zone. The results show anomalous radon level in the sampled station near the fault zone, which gave a radon value higher by three times than background. This study draws its importance from the fact that in Jordan many cities and villages have been established over an intensive faulted land. Also, our study has considerable implications for the future radon mapping. Moreover, radon gas is proved to be a good tool for fault zones detection

  13. Radon in geological medium

    Energy Technology Data Exchange (ETDEWEB)

    Hricko, J [GEOCOMPLEX, a.s., Bratislava (Slovakia)

    1996-12-31

    The paper presented deals with behavior of the radon in geological medium and with some results of the radon survey in Bratislava and Kosice regions. 1) The a{sub v} has been detected in the holes 0.80 m deep. The density of observations - 3 reference areas (one represents 20 stations) per 1 km{sup 2}. The radon risk maps in 1:25000 and 1:50000 scales have been compiled. The 56.8% of the project area lies in low radon risk, 37.6% in medium radon risk and 5.6% in high radon risk. Follow-up monitoring of the equivalent volume radon activity (EVRA) at the flats, located in the areas with high radon risk of the surface layer, has showed values several times higher than Slovak limits (Marianka, Raca, Vajnory). The evidence that neotectonic is excellent medium for rising up emanation to the subsurface layer, is shown on the map. The tectonic zone of Liscie udolie in Bratislava-Karlova Ves area has been clearly detected by profile radon survey (a{sub v} > 50 kBq/m{sup 3}). 2) At present, northern half of the area of Kosice in question was covered by radon survey. The low and medium radon risks have been observed here, while localities with high radon risk are small in extent. The part of radon risk and soil permeability map from northern Kosice area is shown. (J.K.) 3 figs., 2 refs.

  14. Radon in geological medium

    International Nuclear Information System (INIS)

    Hricko, J.

    1995-01-01

    The paper presented deals with behavior of the radon in geological medium and with some results of the radon survey in Bratislava and Kosice regions. 1) The a v has been detected in the holes 0.80 m deep. The density of observations - 3 reference areas (one represents 20 stations) per 1 km 2 . The radon risk maps in 1:25000 and 1:50000 scales have been compiled. The 56.8% of the project area lies in low radon risk, 37.6% in medium radon risk and 5.6% in high radon risk. Follow-up monitoring of the equivalent volume radon activity (EVRA) at the flats, located in the areas with high radon risk of the surface layer, has showed values several times higher than Slovak limits (Marianka, Raca, Vajnory). The evidence that neotectonic is excellent medium for rising up emanation to the subsurface layer, is shown on the map. The tectonic zone of Liscie udolie in Bratislava-Karlova Ves area has been clearly detected by profile radon survey (a v > 50 kBq/m 3 ). 2) At present, northern half of the area of Kosice in question was covered by radon survey. The low and medium radon risks have been observed here, while localities with high radon risk are small in extent. The part of radon risk and soil permeability map from northern Kosice area is shown. (J.K.) 3 figs., 2 refs

  15. Airborne radon-222 measurement by active sampling with charcoal adsorption and gamma-ray spectrometry

    International Nuclear Information System (INIS)

    Shizuma, Kiyoshi; Wen, Xiao-qiong; Fukami, Kenji; Iwatani, Kazuo; Hamanaka, Shun-ichi

    1998-01-01

    A simple method for measuring radon concentration in air is presented. Airborne radon is adsorbed in a charcoal bed by an active air sampling. In time, the adsorbed radon comes to attain radioactive equilibrium with its short-lived progeny 214 Pb. Utilizing this fact, radon concentration is derived from γ-ray measurement of 214 Pb. This method is estimated to be capable of detecting radon concentration in air down to 0.79 Bq·m -3 . The adsorption coefficient obtained with the method is compared with what is obtainable with passive sampling. Applications of this method to indoor and outdoor radon measurements are described. (author)

  16. Alpha scintillation radon counting

    International Nuclear Information System (INIS)

    Lucas, H.F. Jr.

    1977-01-01

    Radon counting chambers which utilize the alpha-scintillation properties of silver activated zinc sulfide are simple to construct, have a high efficiency, and, with proper design, may be relatively insensitive to variations in the pressure or purity of the counter filling. Chambers which were constructed from glass, metal, or plastic in a wide variety of shapes and sizes were evaluated for the accuracy and the precision of the radon counting. The principles affecting the alpha-scintillation radon counting chamber design and an analytic system suitable for a large scale study of the 222 Rn and 226 Ra content of either air or other environmental samples are described. Particular note is taken of those factors which affect the accuracy and the precision of the method for monitoring radioactivity around uranium mines

  17. Determination of radon levels in Mexico City

    International Nuclear Information System (INIS)

    Pena G, P.

    1992-01-01

    The study of the determination of radon levels in the houses room in Mexico City is part of the project Emanometry of the radon. To carry out this study, the passive method was used, which consists of: thin film dosemeter of cellulose nitrate, container of the same one and spark accountant. The method is based on the mensurations of exhibition of the number of marks of alpha track is of the open type and it allows to average the radon activity along several weeks and it presents low concentrations. This study was carried out in 4 periods of exhibition of 3 months each one. (Author)

  18. Radiation exposure due to radon and radon daughters

    International Nuclear Information System (INIS)

    Ullmann, W.

    1976-01-01

    Underground miners working over long periods of time in mines with a high content of radon and radon daughters belong to that group of occupationally exposed persons who are subject to the greatest somatic risk, with values especially high if the permissible dose limits are exceeded. Follwing an overview of the permissible limits currently in use for radon and radon daughters as well as the results of examinations performed in nationally-owned underground mining of the G.D.R., considerations are presented on the measuring quantities requisite for statistical, control and safety measurements in this field. Finally, conclusions are drawn concerning the measuring procedures and instruments to be employed for practical work. (author)

  19. Comparative study of short- and long-term indoor radon measurements

    Energy Technology Data Exchange (ETDEWEB)

    Al-Jarallah, M.I. [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia)], E-mail: mibrahim@kfupm.edu.sa; Fazal-ur-Rehman,; Abdalla, Khalid [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia)

    2008-08-15

    Short-term indoor radon measurements are used widely. Therefore, it is interesting to find out a correlation between these measurements and long-term measurements which reflect a better average radon concentration of individual measurement. To find the correlation between the two measurements of indoor radon concentrations at low radon levels, a study was carried out at 34 locations of King Fahd University of Petroleum and Minerals (KFUPM), Dhahran, Saudi Arabia using active and passive methods. In the short-term active method, a radon gas analyzer (AlphaGUARD) was used for a duration of 24 h in each measurement. In the long-term passive method, CR-39 based radon dosimeters were utilized for a period of 6 months, from January 2006 to June 2006. The short-term active measurements showed that the average, minimum and maximum radon concentrations were 19, 8 and 58Bqm{sup -3}, respectively, with a standard deviation of 8.6Bqm{sup -3}. The long-term passive measurements showed that the average, minimum and maximum radon concentrations were 25, 10 and 67Bqm{sup -3}, respectively, with a standard deviation of 12Bqm{sup -3}. The two measurements showed a poor correlation (R{sup 2}=0.38). The long-term measurements showed on the average higher concentrations by a factor of 1.3.

  20. BGS Radon Protective Measures GIS

    International Nuclear Information System (INIS)

    Appleton, D.; Adlam, K.

    2000-01-01

    The British Geological Survey Radon Protective Measures Geographical Information System is described. The following issues are highlighted: Identification of development sites where radon protection is required in new dwellings; Mapping radon potential on the basis of house radon and geology; Radon Protective Measures GIS; Radon site reports; and Follow-up radon protective measures sire reports

  1. Procedure for the characterization of radon potential in existing dwellings and to assess the annual average indoor radon concentration

    International Nuclear Information System (INIS)

    Collignan, Bernard; Powaga, Emilie

    2014-01-01

    estate transaction. • Able to define a method to classify building with regard to radon exposure

  2. Radon and its daughters in various British mines

    International Nuclear Information System (INIS)

    Strong, J.C.; Laidlaw, A.J.; O'Riordan, M.C.

    1975-11-01

    The results of surveys of radon and radon daughter concentrations in a large number of mines, other than coal mines, in Great Britain are presented. Measurement methods are described, and estimates of the average radon daughter concentrations are given. A comparison is made between the results of radon and radon daughter determination. The radon daughter exposure of about 40% of the non-coal miners covered by a survey in 1973 was estimated to be above the recommended limit of 4 WLM in a year. Recommendations were made for reducing this exposure and for radiological surveillance. A follow-up survey shows some improvement partly due to the implementation of these recommendations, and by October 1975, the number of miners estimated to have an annual exposure above the recommended limit had fallen to about 30% of those included in the survey. (author)

  3. Analysis of the main factors affecting the evaluation of the radon dose in workplaces: The case of tourist caves

    International Nuclear Information System (INIS)

    Sainz, Carlos; Quindos, Luis Santiago; Fuente, Ismael; Nicolas, Jorge; Quindos, Luis

    2007-01-01

    High concentrations of radon exist in several workplaces like tourist caves mainly because of the low ventilation rates existing at these enclosures. In this sense, in its 1990 publication, the ICRP recommended that high exposures of radon in workplaces should be considered as occupational exposure. In developed caves in which guides provide tours for the general public great care is needed for taking remedial actions concerning radon, because in some circumstances forced ventilation may alter the humidity inside the cave affecting some of the formations or paintings that attract tourists. Tourist guides can work about 1900 h per year, so the only option to protect them and other cave workers from radon exposure is to apply an appropriate system of radiation protection mainly based on limitation of exposure by restricting the amount of time spent in the cave. Because of the typical environmental conditions inside the caves, the application of these protecting actions requires to know some indoor air characteristics like particle concentration, as well as radon progeny behaviour in order to get more realistic effective dose values In this work the results of the first two set of radon measurements program carried out in 10 caves located in the region of Cantabria (Spain) are presented

  4. Airflow measurement techniques applied to radon mitigation problems

    International Nuclear Information System (INIS)

    Harrje, D.T.; Gadsby, K.J.

    1989-01-01

    During the past decade a multitude of diagnostic procedures associated with the evaluation of air infiltration and air leakage sites have been developed. The spirit of international cooperation and exchange of ideas within the AIC-AIVC conferences has greatly facilitated the adoption and use of these measurement techniques in the countries participating in Annex V. But wide application of such diagnostic methods are not limited to air infiltration alone. The subject of this paper concerns the ways to evaluate and improve radon reduction in buildings using diagnostic methods directly related to developments familiar to the AIVC. Radon problems are certainly not unique to the United States, and the methods described here have to a degree been applied by researchers of other countries faced with similar problems. The radon problem involves more than a harmful pollutant of the living spaces of our buildings -- it also involves energy to operate radon removal equipment and the loss of interior conditioned air as a direct result. The techniques used for air infiltration evaluation will be shown to be very useful in dealing with the radon mitigation challenge. 10 refs., 7 figs., 1 tab

  5. Radon Measurements in Vojvodina

    International Nuclear Information System (INIS)

    Bikit, I.; Bikit, K.; Forkapic, S.; Mrda, D.; Nikolov, J.; Todorovic, N.; Veskovic, M.

    2013-01-01

    Recent analyses of epidemiological studies of lung cancer risk from residential exposures demonstrate a statistically significant increase per unit of exposure below average annual concentrations of about 200 Bq/m 3 . Indoor radon measurements performed in Novi Sad in about 400 houses and flats are presented and discussed in this paper. By measuring gamma-activity of radon daughters, radon activity concentration was determined to be 50 Bq/m 3 . In Vojvodina region indoor radon levels were measured by alpha track detectors CR-39 on about 3000 locations during the winter seasons in the period of three years (2003-2005). The main aim of the present study was to explore the critical group of population for radon exposure and to estimate maximal annual doses. Existing radon maps which identify regions with elevated radon levels will improve data collection and analysis for the future radon campaigns. Collaboration on the JRC program of European indoor radon map and implementation of grid system are also discussed.(author)

  6. Radon and cancer

    International Nuclear Information System (INIS)

    2011-01-01

    This publication proposes an overview on what is known about the carcinogenic effect of radon. It recalls the origin of radon, its presence in the environment, and its radioactivity. It comments data on the relationship between exposure to radon and lung cancer, and with other forms of cancer. It discusses the role of the exposure level, and the cases of professional and domestic exposure with respect to these risks. It indicates the hazardous areas in France which are well identified, outlines that smokers are more likely victims of risks related to radon, that this risk is still underrated and underestimated (notably by the public). It gives an overview of existing regulations regarding exposure to radon, of public health policies and national plans concerning radon, and recalls some WHO recommendations

  7. Radon concentration distribution mapping in a small detached house

    International Nuclear Information System (INIS)

    Muellerova, Monika; Moravcsik, Attila; Holy, Karol; Hutka, Miroslav; Hola, Olga

    2013-01-01

    Radon activity concentration was investigated in an older, single storey detached house. The rooms of the house are in contact with the bedrock. The house is fitted with plastic windows and populated mostly during the summer. Integral (Raduet) and continuous (AlphaGUARD) methods were used to measure the radon activity concentration. Average radon and thoron activity concentrations in the house were 150 Bq/m 3 and 40 Bq/m 3 , respectively. The impact of the house occupancy on radon activity concentration was significant only during the summer months when a decrease of radon activity concentration was recorded due to an increased ventilation rate. In the autumn and winter months, the impact of the house occupancy on radon activity concentration was relatively small - up to 20 %. The increases in radon activity concentration after the room had been thoroughly ventilated were analysed in order to estimate the ventilation rate and the rate of radon supply into the house. (orig.)

  8. How to Ensure Low Radon Concentrations in Indoor Environments

    DEFF Research Database (Denmark)

    Rasmussen, Torben Valdbjørn; Wraber, Ida Kristina

    2011-01-01

    This paper focuses on methods for measuring radon levels in the indoor air in buildings as well as on concrete solutions that can be carried out in the building to prevent radon leakage and to lower the radon concentration in the indoor air of new buildings. The radon provision in the new Danish...... Building Regulations from 2010 has been tightened as a result of new recommendations from the World Health Organization. Radon can cause lung cancer and it is not known whether there is a lower limit for its harmfulness. It is therefore important to reduce the radon concentration as much as possible in new...... buildings. The airtightness is a major factor when dealing with radon in buildings. Above the ground it is important to build airtight in compliance with energy requirements and against the ground it is important to prevent radon from seeping into the building. There is a direct connection between...

  9. Radon in Public Waterworks at the Cities of Pozega-Slavonia County

    International Nuclear Information System (INIS)

    Radolic, V.; Saric, I.; Miklavcic, I.

    2008-01-01

    At the end of year 2005, there was a sampling campaign of water samples from the public waterworks at the cities and municipalities of Pozega-Slavonia County. Number of measuring locations was defined by the number of inhabitants in each city or municipality with criterion of 1 location per 3000 inhabitants. Samples were taken from private wells as well, at those municipalities without public waterworks infrastructure. Radon measurements in water samples were performed by Alpha GUARD measuring system using standard procedure for quick measurements. The obtained values were in range of 3.5 to 35.9 Bq l -1 with arithmetic mean of 15.0 Bq l -1 and standard deviation of 8.2 Bq l -1 . These values are significantly lower than reference level of 100 Bq l -1 recommended by the European Commission; a concentration above this level warrants consideration of possible remedial action. Statistical t-test pointed out there is significant difference between average radon concentrations in water sampled from public supply and those from private wells. The estimation of annual effective dose received by an inhabitant of Pozega-Slavonia County from ingestion of water from public supply containing averaged 15.0 Bq l -1 of radon is 38 μSv/year. In addition, the annual effective dose due to inhalation of radon and its short lived daughters for the population of Pozega-Slavonia County is around 50 times greater (1.9 mSv/year) so as the risk for public health.(author)

  10. Radon awareness in Ireland: a assessment of the effectiveness of radon road shows

    International Nuclear Information System (INIS)

    Synnott, H.

    2006-01-01

    Full text: In late 2004 the Radiological Protection Institute of Ireland (R.P.I.I.) initiated a series of radon road shows in areas designated as High Radon Areas 1 in the R.P.I.I. s national radon survey of homes. The main objective of these road shows was to provide information to a local audience on the risks of exposure to radon. These road shows target both employers and householders. Each road show has the same general format. A presentation and/or meeting with a major employer representative group within the area. The purpose is to make employers aware of the risks associated with exposure to radon in the workplace and to highlight their obligations under current Irish health and safety legislation regarding radon in the workplace. An information stand on radon manned by R.P.I.I. staff members in a local shopping centre or other similar area. This provides those concerned about radon with accessible information on radon exposure risks, how to measure radon and the steps a home owner could take to reduce radon concentrations where necessary. Where possible R.P.I.I. staff members visit one or more schools in the general area. A short presentation on radon was given to students and students were given an opportunity to asks questions Maximizing media exposure to publicize our visits is vital to the success of these visits. Each visit is preceded by a Press Release whose main aim is to brief local and national media on the radon issue so as to achieve maximum publicity mainly through radio and television coverage. In general the media are very interested in the whole radon area and R.P.I.I. staff members have given 57 radio and 10 television interviews to date since the commencement of this initiative. The four road shows carried out to date have been successful in encouraging householders to carry out radon measurements. Since the start of the road shows to the present, the R.P.I.I. has seen a 44% increase in the number of householders requesting radon

  11. Radon and its decay products in housing

    International Nuclear Information System (INIS)

    Swedjemark, G.A.

    1985-01-01

    Methods have been worked out for evaluation of the uncertainties due to temporal variations in the annual averages for the concentrations of radon-222 (radon) and radon daughters (RnD) indoors. These methods have been applied to the results from long-term measurements of radon in a few houses. The possible use of correction factors in order to get a more adequate annual average have also been studied and some examples have been given. On the basis of country-wide investigations carried out during 1955-56 and during 1972-75 averages of the radon concentrations in housing existing in 1950 and 1975 were calculated six years ago to be 29 and 71 Bq m -3 respectively. A new country-wide investigation with the aim of obtaining values representative for the country was carried out during 1980-82. On the basis of these results a new calculation was made of the concentrations in dwelllings existing in 1975 to 101 Bq m -3 and also for the 1980 housing stock to 98 Bq m -3 . These results are discussed and the collective dose equivalents in the Swedish population have been calculated. (author)

  12. High indoor radon concentrations in some Swedish waterworks

    International Nuclear Information System (INIS)

    Aakerblom, G.; Hagberg, N.; Mjoenes, L.; Heiberg, A.

    2002-01-01

    High indoor radon concentrations in buildings used for water treatment are not uncommon. When raw water is processed in an open system radon escapes from the water to the indoor air of the premises. It is not unusual that the staff of the waterworks have their offices in the building where the water is processed. If large volumes of water are processed and the evaporated radon can reach the workplaces the indoor radon concentration can be very high even if the radon concentration of the raw water is moderate. Groundwaters from aquifers in bedrock and soil and surface water that has been infiltrated through deposits of sand or gravel have the potential to cause high indoor radon levels. In surface water emanating directly from a lake or a river the radon concentrations are normally too low to cause problems. Three waterworks in central Sweden have been studied, Ludvika, Fredriksberg and Kolbaeck. The radon concentrations in the raw water of these waterworks are from 85 Bq/l to 300 Bq/l. Average indoor radon concentrations exceeding 17,000 Bq/m 3 have been measured in Ludvika with peaks of almost 37,000 Bq/m 3 . In Kolbaeck radon concentrations up to 56,000 Bq/m 3 have been measured. It is quite possible that employees of waterworks can receive doses exceeding 20 mSv per year (calculated according to ICRP:s dose conversion convention). Measurements of radon and gamma radiation from the waterworks are reported and methods to lower the indoor radon concentrations are discussed. (author)

  13. The measure and control system of mini-type radon room based on PC104

    International Nuclear Information System (INIS)

    Zhou Shumin; East China Inst. of Technology, Fuzhou; Tang Bin; Sun Yamin

    2005-01-01

    Radon room is one of the standard equipment which demarcates radon measure instrument. The paper discusses the dynamic method and mathematic model which keeps the radon consistence stability in radon room. The system is developed on PC104. The system can monitor the radon consistence and replenishment radon according the radon control parameter. (authors)

  14. Small area mapping of domestic radon, smoking prevalence and lung cancer incidence – A case study in Northamptonshire, UK

    International Nuclear Information System (INIS)

    Denman, Antony R.; Rogers, Stephen; Ali, Akeem; Sinclair, John; Phillips, Paul S.; Crockett, Robin G.M.; Groves-Kirkby, Christopher J.

    2015-01-01

    Smoking and radon both cause lung cancer, and together the risk is significantly higher. UK public health campaigns continue to reduce smoking prevalence, and other initiatives identify houses with raised radon (radon-222) levels and encourage remedial action. Smoking prevalence and radon levels in the UK have been mapped at Primary Care Trust level. This paper extends that work, using a commercial socio-demographic database to estimate smoking prevalence at the postcode sector level, and to predict the population characteristics at postcode sector level for 87 postcode sectors in Northamptonshire. Likely smoking prevalence in each postcode sector is then modelled from estimates of the smoking prevalence in the different socio-economic groups used by the database. Mapping estimated smoking prevalence, radon potential and average lung cancer incidence for each postcode sector suggested that there was little correlation between smoking prevalence and radon levels, as radon potential was generally lower in urban areas in Northamptonshire, where the estimates of smoking prevalence were highest. However, the analysis demonstrated some sectors where both radon potential and smoking prevalence were moderately raised. This study showed the potential of this methodology to map estimated smoking prevalence and radon levels to inform locally targeted public health campaigns to reduce lung cancer incidence. - Highlights: • We use a commercial socio-demographic database to estimate smoking prevalence in small areas in Northamptonshire, UK. • We map the estimated smoking prevalence and average domestic radon levels in these small areas. • We estimate annual average lung cancer incidence in these small areas. • The methodology is useful to evaluate and plan localised public health campaigns to reduce lung cancer incidence.

  15. Indoor radon and decay products: Concentrations, causes, and control strategies

    Energy Technology Data Exchange (ETDEWEB)

    Nero, A.V.; Gadgil, A.J.; Nazaroff, W.W.; Revzan, K.L.

    1990-11-01

    This report is another in the on going technical report series that addresses various aspects of the DOE Radon Research Program. It provides an overview of what is known about the behavior of radon and its decay products in the indoor environment and examines the manner in which several important classes of factors -- structural, geological, and meteorological -- affect indoor radon concentrations. Information on US indoor radon concentrations, currently available monitoring methods and novel radon control strategies are also explored. 238 refs., 22 figs., 9 tabs.

  16. Report on game species of concern associated with the Gunnison Remedial Action Project, Gunnison, Colorado

    International Nuclear Information System (INIS)

    1991-09-01

    This report provides background information and data used in the analysis of potential impacts to game species reported in the Environmental Assessment of the Proposed Remedial Action at the Gunnison Uranium Mill Tailings Site, Gunnison, Colorado. That environmental assessment provides details regarding proposed remedial action at the Gunnison site along with a description of existing conditions and projected environmental impacts. A summary of the proposed action is provided. The uranium mill tailings and other contaminated materials at the Gunnison processing site would be transported to the Landfill disposal site via the Tenderfoot Mountain (TM) haul route. The remedial action would take place over a three-year period with two six-month winter shutdowns. The first year would consist of site preparation and haul road construction. The second year would consist of moving the tailings. Movement of the radon/infiltration barrier cover material and erosion protection material would take place during the third construction year. The material used to cover the pile is fine-grained material for the radon/infiltration barrier (Sixmile Lane borrow site) and rock for erosion protection from the Chance Gulch borrow site. The location of the borrow sites used to obtain these materials and the associated haul roads is shown

  17. In-field radon measurement in water: a novel approach

    International Nuclear Information System (INIS)

    Talha, S.A.; Meijer, R.J. de; Lindsay, R.; Newman, R.T.; Maleka, P.P.; Hlatshwayo, I.N.

    2010-01-01

    This paper presents a novel approach of measuring radon in-water in the field by inserting a MEDUSA gamma-ray detector into a 210 L or 1000 L container. The experimental measurements include investigating the effect of ambient background gamma-rays on in-field radon measurement, calibrating the detector efficiency using several amounts of KCl salt dissolved in tap water, and measuring radon in borehole water. The results showed that there is fairly good agreement between the field and laboratory measurements of radon in water, based on measurements with Marinelli beakers on a HPGe detector. The MDA of the method is 0.5 Bq L -1 radon in-water. -- Research highlights: →Radon-in-water, large volume container, in-field measurements, MEDUSA gamma-ray detection system.

  18. Formulation of the fundamental basis for the evaluation of the comparability of different measuring method for the determination of ground air radon concentration. Vol. 2. Report on ground air radon measurements - influence factors, measuring methods, evaluation; Erarbeitung fachlicher Grundlagen zur Beurteilung der Vergleichbarkeit unterschiedlicher Messmethoden zur Bestimmung der Radonbodenluftkonzentration. Bd. 2. Sachstandsbericht ''Radonmessungen in der Bodenluft - Einflussfaktoren, Messverfahren, Bewertung''

    Energy Technology Data Exchange (ETDEWEB)

    Kemski, J.; Klingel, R.; Siehl, A.; Neznal, M.; Matolin, M.

    2012-03-15

    The report on ground air radon measurements covers the following issues: Introduction; Radon in the geogenic underground: emanation, migration, exhalation; Influencing factors: geochemical parameters, structural situation, geomorphology, exogenic effects; Ground air measurements: site exploration, tectonics, earth quake prognosis, radon in ground air and buildings; Radon measurement: sampling and measuring methods, error consideration, comparative measurements, practical examples; measuring regulations and recommendations; Variability of the radon concentration: temporal variation, sampling depth, spatial variations; Evaluation and conclusions.

  19. Absolute measurement of environmental radon content

    International Nuclear Information System (INIS)

    Ji Changsong

    1987-01-01

    A transportable meter for environmental radon measurement with a 40 liter decay chamber is designed on the principle of Thomas two-filter radon content absolute measurement. The sensitivity is 0.37 Bq·m -3 with 95% confidence level. This paper describes the experimental method of measuremment and it's intrinsic uncertainty. The typical intrinsic uncertainty (for n x 3.7 Bq·m -3 radon concentration) is <10%. The parameter of exit filter effeciency is introduced into the formula, and the verification is done for the case when the diameter of the exit filter is much less than the inlet one

  20. A Radon Chamber without Radium Source for Detector Calibration and Radon Measurements

    International Nuclear Information System (INIS)

    Al-Azmi, D.; Karunakara, N.

    2008-01-01

    A radon chamber of volume 216 liters was designed and constructed for calibration of radon detectors and radon test measurements. The main feature of this chamber is that the active 226 Ra source, to generate the 222 Rn inside the chamber volume, is not required. Instead, 222 Rn from soil gas is utilized for this purpose. The supply of radon comes from the soil gas. Soil gas is drawn from the soil to fill the chamber with high radon concentration levels (∼ 80 kBq/m3). Desired radon concentration levels can be obtained by drawing the soil gas for different time durations and/or flow rate (author)

  1. RADON AND CARCINOGENIC RISK IN MOSCOW

    Directory of Open Access Journals (Sweden)

    S. M. Golovanev

    2015-01-01

    Full Text Available Objective: comparative evaluation of carcinogenic risk inMoscowfrom radon in indoor and atmospheric pollutants.Materials and methods: the lung cancer incidence in Moscow; radiation-hygienic passport of the territory; .U.S. EPA estimated average age at all and radon induced deaths, years of life lost; Report of UNSCEAR 2006 and WHO handbook on indoor radon, 2009. Trend analysis of incidence; evaluation of the excess relative risk; assessment of ratio radon-induced population risk and published values оf total population carcinogenic risk from chemical carcinogens.Results: it is shown that the 304 cases of lung cancer per year (1. 85 10-3 on average from 2006 to 2011 (21280diseases for 70 years in addition to background level induced by radon; the differences in average trends of all lungcancer incidence in the districts can exceed 25%.Conclusion. The potential of risk reduction by measures of mitigation radon concentration exceeds 5 times the cost efficiency to reduce emissions from vehicles and can reduce cancer incidence, on average 236 cases per year; population risk 16520 cases over 70 years or save not less than 2832 person-years of life per year. The annual effect of reducing losses from not-survival of 12 years as a result of radon-induced lung cancer deaths exceeds 14160000 dollars. The evaluating of the carcinogenic risk from radon in accordance with the definition of population risk increases the predictive evaluation of the effectiveness of preventive measures more than twice.

  2. Regressionanalysis of radon measurements; Regressionsanalysen von Radonmessungen

    Energy Technology Data Exchange (ETDEWEB)

    Buermeyer, J.; Neugebauer, T.; Hingmann, H.; Grimm, V.; Breckow, J. [Technische Hochschule Mittelhessen (THM), Giessen (Germany). Inst. fuer Medizinische Physik und Strahlenschutz (IMPS); Gundlach, M. [Technische Hochschule Mittelhessen (THM), Giessen (Germany). Fachbereich fuer Mathematik, Naturwissenschaften und Informatik

    2016-07-01

    In the course of the renewal of the Radiation Protection Guidelines for Germany, radon becomes a more prominent concern. Thus, it is important to gain more information on the temporal behaviour of radon and its measureable parameters. This work focuses on the determination on possible influencing factors using regression-analysis methods. So far the radon concentration has been analysed and it was revealed, that the most important impact comes from the gradient of the temperature and pressure as the difference of the values in and outside the building. The carbon dioxide, which was logged as an indicator for the influences of the inhabitant does not show the high influence on the Radon levels as expected.

  3. Radon house doctor

    International Nuclear Information System (INIS)

    Nitschke, I.A.; Brennan, T.; Wadach, J.B.; O'Neil, R.

    1986-01-01

    The term house doctor may be generalized to include persons skilled in the use of instruments and procedures necessary to identify, diagnose, and correct indoor air quality problems as well as energy, infiltration, and structural problems in houses. A radon house doctor would then be a specialist in radon house problems. Valuable experience in the skills necessary to be developed by radon house doctors has recently been gained in an extensive radon monitoring and mitigation program in upstate New York sponsored by Niagara Mohawk Power Corporation and the New York State Energy Research and Development Authority. These skills, to be described in detail in this paper, include: (i) the use of appropriate instruments, (ii) the evaluation of the symptoms of a radon-sick house, (iii) the diagnostic procedures required to characterize radon sources in houses, (iv) the prescription procedures needed to specify treatment of the problem, (v) the supervision of the implementation of the treatment program, (vi) the check-up procedures required to insure the house cured of radon problems. 31 references, 3 tables

  4. Analysis of the cost effectiveness of protecting indoor air from radon from the underlying structures

    International Nuclear Information System (INIS)

    Skrabalek, P.

    2017-01-01

    Exposure to radon in buildings is the largest and yet underestimated source of ionizing radiation doses of the Slovak population. The most affected are the people currently living in family houses, where the radon from the building's constructions is also exposed to radon from building background. At work the authors have shown that protecting the air of family houses and other buildings from radon pollution from underlying structures is not an economic but a political issue. They have shown that preventive protective measures must be taken in the construction of each house, whether it is a family house or another building. The cost of preventive measures for the construction of family houses, while maintaining the current trend, will amount to around 3 million Eur each year, because during that time, approximately 10,300 new buildings were built. These costs are entirely at the expense of builders, because radon protection must be part of the construction project and at present prices range from 225 to 405 Eur per building. Benefits will begin to show at the earliest 25-30 years after construction, and will reach around 12 million Eur (calculated at today's medical care prices and the current minimum wage). The projected costs of identifying occupied homes that urgently need to make remedial measures will reach about 1 million Eur / yr and cover 20,000 homes. It will be necessary to build a laboratory of alpha tremor dosimetry within Slovak legal metrology, with a capacity to process about 50,000 dosimetric kits annually. Examination of the occupied houses by this procedure will last for at least 40 years, because apart from geological and geophysical criteria, there is nothing to exclude any group of houses from the survey. According to estimates from previous surveys, about 16,700 objects need to be identified annually, which need to optimize radon concentration by technical or construction means. The remedial measures will need to be around 24.6 million Eur, of

  5. Radon generator and the method of radium carrier fabrication

    International Nuclear Information System (INIS)

    Czerski, B.

    1992-01-01

    The radon generator construction and the method of radium carrier fabrication has been the subject of the patent. The generator is a cylindrical vessel with gas valves system and two filters inside. Between them the radium carrier has been located. As a carrier polyurethane foam has been used. The carrier is obtained in a generator vessel from polyester resin in the presence of activated mixture of engine oil, zinc-organic catalyst and toluene. To the obtained mixture the radium chloride in the solution of hydrochloric acid is added. The carrier foam is produced by mechanical stirring of substrates inside the vessel and drying in 50 C in a heater. 1 fig

  6. Radon health hazards of some rocks of Iranian origin, frequently used as building stones

    International Nuclear Information System (INIS)

    Noori, H.; Ranjbar, A.H.

    2011-01-01

    Radon exhalation rate from various types of stones, used inside the living buildings, is a major factor for evaluation of the environmental radon level. To verify the significance and lethal impacts of this unknown and obscure source of radiation upon the people around the world, the exhaled radon gas concentrations from the rocks, granodiorite, granite, limestone and aragonite, and the effect of their block sizes on the exhalation rate, have been studied. The block samples, collected from their ores, were transferred to plastic containers in which the CR-39 detectors could properly be placed and air tightened, for concentration measurements. The results show the radon concentration of 7.4 ± 0.8, 6.6 ± 0.6, 0.08 ± 0.02 and 0.09 ± 0.02 kBq m -3 for granodiorite, granite, limestone and aragonite, respectively. The corresponding annual dose values in a closed environment are: 186 ± 20, 166 ± 15, 2.5 ± 1 and 2 ± 1 mSv y -1 . These absorbed dose values indicate that granodiorite and granite when used inside the buildings could increase the risk of various cancers while aragonite and limestone have much lower risks and are recommended for use inside the buildings. The former ones when used in the closure areas remedial action should be implemented. The results do not show obvious dependence between the rock size of the samples and their radon exhalation rate. (author)

  7. Radon in Dwellings in the Republic of Kalmykia. Results from the National Radon Survey 2006-2007

    International Nuclear Information System (INIS)

    Aakerblom, Gustav; German, Olga; Soederman, Ann-Louise; Stamat, Ivan; Venkov, Vladimir

    2009-02-01

    The National Radon Survey in the Republic of Kalmykia, Russian Federation during 2006-2007 was carried out in a cooperation project between the Swedish Radiation Protection Authority (SSI) and the Russian Institute of Radiation Hygiene (RIRH). In August 2006 SSI, RIRH, federal and local authorities carried out a field study in Kalmykia when radon daughter measurements (equilibrium equivalent radon concentrations in the air) and gamma radiation measurements were made in 103 buildings. Gamma spectrometry measurements were made at several sites. During the visit the cooperating parties devoted some time to the education of local authorities on radon related issues. During three months in the winter season 2006-2007, long term radon trace measurements were made in 525 randomly chosen dwellings in the Republic of Kalmykia. The radon gas activity varied between 3 and 973 Bq/m 3 , with a mean value of 122 Bq/m 3 . In 19 of a total of 835 measurement points, the radon activity exceeded the maximum permitted value in Russia of 200 Bq/m 3 of EERC. The year-round radon trace measurement were made in 20 houses in Elista, the capital of the Republic of Kalmykia, for comparison with the three-month measurements. The year-round measurements showed some higher values for the radon activity, and a correction factor of 0.85 was applied. Using data on the number of people living in detached houses and apartments, and applying the radon activities measured, the number of new lung cancer cases caused by radon was calculated to be 20 to 40 of the 100 new cases reported annually. The methods of construction of the dwellings in Kalmykia is greatly influenced by the history and culture. Most of them were built after World War II and there are only a few that are newly built because of the poor economic situation and the low population growth rate in the Republic. Most people live in detached houses, one-storied with 3-5 rooms, built directly on the ground or on coquina blocks or on a cast

  8. Occurrence of radon in the Polish underground tourist routes

    Directory of Open Access Journals (Sweden)

    Jerzy Olszewski

    2015-08-01

    Full Text Available Background: There are about 200 underground tourist routes in Poland. There are caves, mines or underground structures. This paper presents the results of the research intended to identify the extent of the occurrence of radon concentrations in underground areas of tourist routes. Material and Methods: We conducted the measurement of periodic concentrations of radon (1–2 months in the summer using type Tastrak trace detectors. We determined the average concentrations of radon in air in 66 underground tourist routes in Poland. Results: The research results comprise 259 determinations of average radon concentrations in 66 routes. The arithmetic average of the results was 1610 Bqm–3, and the maximum measured concentration was over 20 000 Bqm–3. The minimum concentration was 100 Bqm–3 (threshold method considering the arithmetic average of the measurements. It was found that in 67% of the routes, the average concentration of radon has exceeded 300 Bqm–3 and in 22 underground routes it exceeded 1000 Bqm–3. Conclusions: Radon which occurs in many Polish underground tourist routes may be an organizational, legal and health problem. It is necessary to develop a program of measures to reduce radon concentrations in underground routes, especially routes located in the former mines. Med Pr 2015;66(4:557–563

  9. Indoor radon measurements and radon prognosis for the province of Kymi, southeastern Finland

    International Nuclear Information System (INIS)

    Pennanen, M.; Maekelaeinen, I.; Voutilainen, A.

    1996-12-01

    The purpose of the regional radon prognosis is to classify areas with different levels of radon risk. The radon prognosis gives the percentages of future homes expected to have indoor radon concentrations exceeding the levels of 200 and 400 Bq/m 3 . It is assumed that no protection against the entry of radon is used in construction. In this study about 5900 indoor radon measurements made in single family houses, semi-detached houses and row houses were used. Data on the location, geology and construction of buildings were determined from maps and questionnaires. An empirical statistical model, the adjusted indoor radon measurements and geological data were used to assess the radon risk from soil and bedrock in different areas. The building sites of the province of Kymi were divided into thirteen sub-areas. The radon prognosis are calculated for the most radon-prone foundation types including 1) houses with a slab-on-grade and 2) houses with a basement or hillside houses with open stairwells between basement and first floor. The radon levels are generally greater in the western part of the area. The radon risk is highest in gravel-dominated esker areas in southwestern, western (in Pyhtaa, Kotka, Anjalankoski, litti, Valkeala) and central (Taipalsaari) parts of the area. The radon risk is also high in some bedrock and till areas, also in southwestern and western parts of the area. In these areas the level of 200 Bq/m 3 will be exceeded in 80 % of new houses. About half of the future houses in these areas will have indoor radon concentrations exceeding 400 Bq/m 3 . The radon risk is lowest in the eastern part of the province of Kymi in every soil type. In this area the level of 200 Bq/m 3 will be exceeded in 30 % of new houses. Below 10 % will exceed 400 Bq/m 3 . (orig.) (14 refs.)

  10. Characteristics of radon concentration distributions measurement with two-filter method in the storage rooms of Ra-Be neutron source and the adjacent laboratories

    International Nuclear Information System (INIS)

    Liu Shuhuan; Chu Jun; Zhao Yaolin; Bao Lihong; Chen Wei; Wu Yuelei

    2012-01-01

    The basic principle of radon measurement with two-filter method is introduced in this paper. The levels of radon concentration in the storage rooms and the adjacent laboratories are measured and compared with the type of FT-648 radon measurement instrument. The measurement results showed that the levels of radon concentration in Ra-Be neutron source storage rooms are not higher than those in the adjacent laboratories, then it can be deduced that no radon gas was leaked out form the shielded and sealed Ra-Be neutron sources. The radon concentrations measured in the laboratories were near to the average level compared to the statistical results of the indoor dwellings' radon concentrations in Xi'an. The values didn't exceed the national standard limits(200 Bq·m -3 ). Furthermore, it is found that the radon concentration value measured at rainy or cloudy day is lesser than that at sunny day, and good ventilation conditions can effectively decrease the indoor radon concentration level. Meanwhile, the mechanisms of the radon concentration distributions in the laboratories influenced by the factors including various weather conditions (rainy, sunny and cloudy), ventilation and different measurement time periods in a day, etc. are primarily analyzed. The measurement results in this work provide some relative reference data for prediction the situations of Ra-Be neutron sources safety storage and experimenters' radiation protection in the laboratories. (authors)

  11. Track-etch detection of radon in soils

    International Nuclear Information System (INIS)

    Cervantes Gonzales, P.; Gonzalez, D.

    1990-01-01

    In this work it is described the methodology to apply the track-etch technique, using detectors of nitrocellulose LR-115, for the detection of radon in soil. It is supported the use of the new detector carries and determined the parameters for revealing and counting of tracks in our conditions. It is shown in a preliminary way that this method gives better possibilities for analysis than another traditional technique to radon detection. The existence of radon was determined in the test zone. 15 refs

  12. Soil radium, soil gas radon and indoor radon empirical relationships to assist in post-closure impact assessment related to near-surface radioactive waste disposal.

    Science.gov (United States)

    Appleton, J D; Cave, M R; Miles, J C H; Sumerling, T J

    2011-03-01

    Least squares (LS), Theil's (TS) and weighted total least squares (WTLS) regression analysis methods are used to develop empirical relationships between radium in the ground, radon in soil and radon in dwellings to assist in the post-closure assessment of indoor radon related to near-surface radioactive waste disposal at the Low Level Waste Repository in England. The data sets used are (i) estimated ²²⁶Ra in the < 2 mm fraction of topsoils (eRa226) derived from equivalent uranium (eU) from airborne gamma spectrometry data, (ii) eRa226 derived from measurements of uranium in soil geochemical samples, (iii) soil gas radon and (iv) indoor radon data. For models comparing indoor radon and (i) eRa226 derived from airborne eU data and (ii) soil gas radon data, some of the geological groupings have significant slopes. For these groupings there is reasonable agreement in slope and intercept between the three regression analysis methods (LS, TS and WTLS). Relationships between radon in dwellings and radium in the ground or radon in soil differ depending on the characteristics of the underlying geological units, with more permeable units having steeper slopes and higher indoor radon concentrations for a given radium or soil gas radon concentration in the ground. The regression models comparing indoor radon with soil gas radon have intercepts close to 5 Bq m⁻³ whilst the intercepts for those comparing indoor radon with eRa226 from airborne eU vary from about 20 Bq m⁻³ for a moderately permeable geological unit to about 40 Bq m⁻³ for highly permeable limestone, implying unrealistically high contributions to indoor radon from sources other than the ground. An intercept value of 5 Bq m⁻³ is assumed as an appropriate mean value for the UK for sources of indoor radon other than radon from the ground, based on examination of UK data. Comparison with published data used to derive an average indoor radon: soil ²²⁶Ra ratio shows that whereas the published data are

  13. Instruments to measure radon-222 activity concentration or exposure to radon-222. Intercomparison 2014

    International Nuclear Information System (INIS)

    Foerster, Elisabeth; Beck, Thomas; Buchroeder, Helmut; Doering, Joachim; Schmidt, Volkmar

    2014-10-01

    According to the Directive 96/29/EURATOM the monitoring of occupational radiation exposures shall base on individual measurements carried out by an approved dosimetric service. Pursuant to the European Directive an approved dosimetric service is a body responsible for the calibration, reading or interpretation of individual monitoring devices.., whose capacity to act in this respect is recognized by the competent authorities. This concept will also be applied to radon services issuing passive radon measurement devices. Passive radon measurement devices 1 using solid state nuclear track detectors or electrets are recommended for individual monitoring of exposures to radon. German regulations lay down that radon measuring devices are appropriate for purposes of occupational radiation monitoring if the devices are issued by recognized radon measurement services, and the measurement service submits devices of the same type issued for radon monitoring to regular intercomparisons conducted by the Bundesamt fuer Strahlenschutz (BfS). A radon measuring service is recognized by the competent authority if it proves its organisational and technical competence, e. g. by accreditation. These regulations have been introduced in the area of occupational radiation exposures. Nevertheless, it is recommended that radon measuring services which carry out radon measurements in other areas (e.g. dwellings) should subject themselves to these measures voluntarily. The interlaboratory comparisons comprise the organization, exposure, and evaluation of measurements of radon activity concentration or exposure to radon. The comparisons only concern radon-222; radon-220 is not in the scope. Radon services being interested can get further information from the European Information System on Proficiency Testing Schemes (EPTIS) and from the BfS websites.

  14. Measurement of Radon concentration in groundwater by technique of nuclear track detector

    International Nuclear Information System (INIS)

    Trinh Van Giap; Nguyen Manh Hung; Dang Duc Nhan

    2000-01-01

    A method for measuring radon concentration in groundwater using nuclear track detector LR-115 stripping is reported. The radon-monitoring device in groundwater is a small box with two pieces of nuclear track detector and all these materials is placed in a plastic bag made by polyethylene. It is very suitable to measure radon concentration in groundwater well in long term. Alpha tracks produced by radon and it daughter on nuclear track detector is counted automatically by spark counting method. The paper also presents some results of radon concentration in some groundwater well and mineral water sources. (author)

  15. Radon in workplaces

    International Nuclear Information System (INIS)

    Reichelt, A.; Lehmann, K.-H.; Reineking, A.; Porstendoerfer, J.; Schwedt, J.; Streil, T.

    2000-01-01

    The radiological assessment of the results of radon measurements in dwellings is not automatically applicable to workplaces due to different forms of utilization, constructional conditions, time of exposure, heating and ventilation conditions, additional aerosol sources, aerosol parameters, chemical substances, etc. In order to investigate the peculiarities of the radon situation in workplaces located inside buildings compared with that in dwellings, long-time recordings of radon, attached radon progeny and unattached radon progeny concentrations ( 218 Po, 214 Pb, 214 Bi) are carried out at several categories of workplaces (e.g. offices, social establishments, schools, production rooms, workshops, kitchens, agricultural facilities). 36 workplaces have been investigated. There have been carried out at least 2-3 long-time recordings for each workplace during different seasons. At the same time the gamma dose rate, meteorological conditions, aerosol particle concentrations have been registered. Many special dates from the workplaces and the buildings have been recorded. Activity size distribution of the aerosol-attached and unattached fraction of short-lived radon decay products have been determinated in 20 workplaces. Mainly the following measurement systems were used: Radon- and Radon Progeny Monitor EQF 3020, SARAD GmbH, Germany. Alpha-Track Radon Detectors, BfS Berlin, Germany. Screen Diffusion Batteries with Different Screens, University of Goettingen, Germany. Low-Pressure Cascade Impactor, Type BERNER. Condensation Nuclei Counter, General Electric, USA. PAEC-f p -Rn-Monitor, University of Goettingen, Germany. Through the measurements, many peculiarities in the course of the radon-concentration, the equilibrium factor F, the unattached fraction f p and the activity size distribution have been determined. These amounts are influenced mainly by the working conditions and the working intervals. The influence of these peculiarities in workplaces on the dose have

  16. Real estate transaction radon test tampering

    International Nuclear Information System (INIS)

    Ritter, D.L.

    1990-01-01

    A thousand-house study, over the past two years showed 35% of the houses were tampered with. This paper offers statistical charts representing the different methods of tampering; A slide presentation showing houses and the non-tamper controls used to monitor EPA closed-house conditions, movement of detectors and covering of detectors. A strong message must be conveyed now, that tampering will not be tolerated by radon technicians, when performing radon tests in the field. A message that incorporates non-tamper controls that are cost effective and provide for reasonably priced testing; A message that will lend credibility to our Radon industry by means of separating the professional test from a do-it-yourself homeowner test. This paper will address that message and offer a program for the prevention of tampering in a house during a PROFESSIONALLY done Radon test

  17. Public perceptions of radon risk

    International Nuclear Information System (INIS)

    Mainous, A.G. III; Hagen, M.D.

    1993-01-01

    Since 1984, a significant amount of media attention has focused on health threats from radon gas exposure. Using a probability telephone survey of adults (n = 685), we studied public perceptions of risk from radon exposure versus other environmental health risks. The results indicated that 92% of those individuals who had heard of radon believe radon to be a health risk, although only 4% believe they are currently exposed to high levels of radon gas. Perception of risk from radon was positively related to other perceptions of environmental risks. Younger and less educated individuals were more likely to perceive radon as a health risk. Women were three-and-one-half times as likely as men to perceive risk from radon. However, there was no significant relationship between perceived risk from radon and cigarette smoking. Media attention has apparently led to public awareness of radon hazards, but further attention is needed to improve smokers' awareness of their special risks from radon

  18. Radon Research Program, FY 1991

    International Nuclear Information System (INIS)

    1992-03-01

    The scientific information being sought in this program encompasses research designed to determine radon availability and transport outdoors, modeling transport into and within buildings, physics and chemistry of radon and radon progeny, dose response relationships, lung cancer risk, and mechanisms of radon carcinogenesis. The main goal of the DOE/OHER Radon Research Program is to develop information to reduce these uncertainties and thereby provide an improved health risk estimate of exposure to radon and its progeny as well as to provide information useful in radon control strategies. Results generated under the Program were highlighted in a National Research Council report on radon dosimetry. The study concluded that the risk of radon exposure is 30% less in homes than in mines. This program summary of book describes the OHER FY-1991 Radon Research Program. It is the fifth in an annual series of program books designed to provide scientific and research information to the public and to other government agencies on the DOE Radon Research Program

  19. Environmental radon

    International Nuclear Information System (INIS)

    Majumdar, S.K.; Schmalz, R.F.; Miller, E.W.

    1990-01-01

    This book covers many aspects of environmental radon, including: historical perspectives; occurrence and properties; detection, measurement, and mitigation, radon and health; and political, economic, and legislative impacts

  20. Working towards residential Radon survey in South America

    International Nuclear Information System (INIS)

    Zielinski, Jan M.; University of Ottawa, ON; Canoba, Analia C.; Shilnikova, Natalia S.; Veiga, Lene H. S.

    2008-01-01

    Information about residential radon levels in low and middle income countries is very sparse. In response to the World Health Organization initiative in the International Radon Project, we propose a research project that will address this knowledge gap in South America by conducting a residential radon survey. Following initial in vitro and in vivo studies of radon and studies of uranium miners exposed to radon, over twenty large case-control studies of lung cancer risk from exposure to residential radon have been completed worldwide by year 2004. Recently pooled data from these individual studies have been analyzed. These collaborative analyses of the indoor studies in Europe, North America, and China provide strong direct evidence that radon is causing a substantial number of lung cancers in the general population. To reduce radon lung cancer risk, national authorities must have methods and tools based on solid scientific evidence to develop sound public health policies. We propose to conduct a survey in ten South American countries using the distribution and analysis of passive alpha tracking detectors in houses selected at random in pre-selected cities in each participating country. We also present an approach to estimate the cost of carrying out such a survey and the radon laboratory infrastructure needed. The results of the proposed survey will allow to conduct assessment of the exposure to residential radon in the populations of South American countries and to assess the health impact of this exposure. The results of the project will also help national health authorities in developing national residential radon action levels and regulations, as well as provide public health guidance for radon awareness and mitigation. (author)

  1. New school radon abatement systems

    International Nuclear Information System (INIS)

    Simon, R.F.; Maniscalco, P.J.

    1990-01-01

    This paper describes the methods used to develop a state-of-the-art Radon Abatement system: all aspects of design and implementation from proper sizing radon ventilation ductwork (RVD) in relationship to the amount of free air available in sub-slab aggregate, review of electrical systems with their monitoring devices from the very basic to the more sophisticated type of installation, review abatement designs for their durability and application as well as methods and techniques. Building codes will also be reviewed for commercial construction applications, spot-lighting the usage of specific materials and techniques and their impact on the industry

  2. Utilization of rice husk ash to enhance radon resistant potential of concrete

    International Nuclear Information System (INIS)

    Jain, Ravinder; Kant, Krishan; Yadav, Mani Kant; Chauhan, R.P.

    2013-01-01

    The radiological and health implication posed by radon and their decay products are well known. The soil containing varying amount of radionuclides is the primary source of indoor radon. The indoor radon level depends upon its entrance through the pores of the ground and floor. Thus it is necessary to restrict the radon from soil to enter indoors by application of materials with low radon diffusion coefficient. The method used for radon shielding purpose in present study utilizes the rice husk ash for substitution with cement to achieve low diffusion coefficient. The study describes the method to optimize the condition of preparation of rice husk ash using X-ray diffraction and fluorescence spectroscopy techniques. The rice husk substitution with cement was optimized by compressive and porosity test of concrete cubes. The diffusion coefficient through concrete modified by rice husk ash was carried out by scintillation radon monitor and specially design radon diffusion chamber. The radon exhalation rates from concrete carried out using active technique decreasing radon emanation from concrete with increase of rice husk ash. The result of present study suggest substitution of 20-30% rice husk ash with cement to achieve lower radon diffusion and exhalation rates with higher compressive strength as compared to control concrete. (author)

  3. UK standards for exposure to radon daughters in dwellings

    International Nuclear Information System (INIS)

    Webb, G.A.M.; O'Riordan, M.C.

    1988-01-01

    The National Radiological Protection Board has issued formal advice on the standards to be adopted in the UK for control of exposures to radon daughters in existing dwellings and for changes in building procedures for future dwellings. The standards are based on those recommended by the International Commission on Radiological Protection but adapted to circumstances in the United Kingdom. The matters taken into account by the Board when formulating its advice include the conversion from measured concentrations of radon to effective dose equivalent and the implied levels of risk, the comparison of these levels with risks from other causes, the numbers of dwellings in which various annual doses are likely to be exceeded, the geographical distribution of these dwellings, the likely costs and effectiveness of various remedial measures and the degree of domestic disruption. The action level for existing dwellings selected by the Board was the same, 20 mSv per annum, as that recommended by the ICRP, but the upper bound for new dwellings of 5 mSv per annum was lower than that suggested by the ICRP

  4. Analysis of noise properties of a class of exact methods of inverting the 2-D exponential radon transform

    International Nuclear Information System (INIS)

    Pan, X.; Metz, C.E.

    1995-01-01

    A general approach that the authors proposed elsewhere reveals the intrinsic relationship among methods for inversion of the 2-D exponential Radon transform described by Bellini et al., by Tretiak and Metz, by Hawkins et al., and by Inouye et al. Moreover, the approach provides an infinite class of linear methods for inverting the 2-D exponential Radon transform. In the work reported here, they systematically investigated the noise characteristics of the methods in this class, obtaining analytical forms for the autocovariance and the variance of the images reconstructed by use of various methods. The noise properties of a new quasi-optimal method were then compared theoretically to those of other methods of the class. The analysis demonstrates that the quasi-optimal method achieves smaller global variance in the reconstructed images than do the other methods of the class. Extensive numerical simulation studies confirm this prediction

  5. The radon transform. Theory and implementation

    International Nuclear Information System (INIS)

    Toft, P.

    1996-01-01

    The subject of this Ph.D. thesis is the mathematical Radon transform, which is well suited for curve detection in digital images, and for reconstruction of tomography images. The thesis is divided into two main parts. Part I describes the Radon- and the Hough-transform and especially their discrete approximations with respect to curve parameter detection in digital images. The sampling relationships of the Radon transform is reviewed from a digital signal processing point of view. The discrete Radon transform is investigated for detection of curves, and aspects regarding the performance of the Radon transform assuming various types of noise is covered. Furthermore, a new fast scheme for estimating curve parameters is presented. Part II of the thesis describes the inverse Radon transform in 2D and 3D with focus on reconstruction of tomography images. Some of the direct reconstruction schemes are analyzed, including their discrete implementation. Furthermore, several iterative reconstruction schemes based on linear algebra are reviewed and applied for reconstruction of Positron Emission Tomography (PET) images. A new and very fast implementation of 2D iterative reconstruction methods is devised. In a more practical oriented chapter, the noise in PET images is modelled from a very large number of measurements. Several packagers for Radon- and Hough-transform based curve detection and direct/iterative 2D and 3D reconstruction have been developed and provided for free. (au) 140 refs

  6. A self-calibrating radon monitor with statistical discrimination

    International Nuclear Information System (INIS)

    Valcov, N.; Purghel, L.

    2002-01-01

    A radon monitor, able to perform the measurement of the radon and its progeny volumic activity, in a gamma-ray or natural radiation background field, was developed. The instrument consists of a 10 l ionization chamber, a high voltage source, an integrating preamplifier, a data acquisition system and a personal computer. A new method for self-calibration of Radon volumic activity measurements, based on the alpha counting with an ionization chamber is also presented

  7. Remedial measures in Czech houses with high radium content in building material

    International Nuclear Information System (INIS)

    Hulka, J.; Thomas, J.

    1999-01-01

    Three groups of houses built from materials having elevated natural radioactivity content were found in the Czech republic. These are: 1) about hundred old houses in Jachymov (Joachimstal) in Northern Bohemia, where residues from factory producing uranium paints were used as plaster and mortar before the World War II (radium concentration up to 1 MBq/kg, indoor gamma dose rate up to 10-100 μGy/h); 2) some 20 000 family houses built from highly emanating aerated concrete with radium content 500-1000 Bq/kg (produced from flying ash) in the period 1963-1980; 3) more than 2000 family houses from slag concrete of radium content about 3 kBq/kg in average (indoor gamma dose rate up to 2 μGy/h) made in the period 1972-83. Remedy measures were undertaken with state financial support. Intervention levels were laid down 200 Bq/m 3 for EEC (equivalent equilibrium radon concentration - it is equivalent to radon gas concentration 500 Bq/m 3 ), 2 μGy/h for indoor gamma dose rate. Weighted sum of indoor radon and indoor gamma dose rate was used if the latter was above 0,5 μGy/h. The central heat recovery ventilation units were used largely as the remedy measures. Some houses were demolished, in some houses local contamination of plasters was removed. Other tested measures (removal of the contaminated building material in great amount, gamma shielding, wall coating, etc.) proved to be not effective or not acceptable in practice. (author)

  8. Radon in Estonian dwellings - Results from a National Radon Survey

    Energy Technology Data Exchange (ETDEWEB)

    Pahapill, Lia; Rulkov, Anne; Rajamaee, Raivo [Estonian Radiation Protection Centre (Kiirguskeskus), Tallinn (Spain); Aakerblom, Gustav [Swedish Radiation Protection Authority, Stockholm (Sweden)

    2003-10-01

    A countrywide survey of radon concentrations in Estonian dwellings was carried out during the period 1998-2001. The survey formed a part of the cooperation program on radiation protection between the Estonian Radiation Protection (Kiirguskeskus) Centre and the Swedish Radiation Protection Authority (SSI). The survey included measurements in a number of dwellings representative for Estonia in detached houses and multifamily buildings (only dwellings on the bottom floor were included in the survey). Altogether, radon concentrations were measured in 515 dwellings, a number large enough to be statistically significant. All measurements were made with alphatrack film detectors of the same type that SSI uses in Sweden. The measurements were made during a 2-3 month period during the winter half-year. Two detectors were used in each dwelling. In Estonia there are 0.17 million dwellings in detached houses and 0.45 million in multi apartment buildings. Of the 1.26 million inhabitants in Estonia. 0.36 million live in detached houses and 0.90 million in multi apartment buildings. Most of the latter were built during the Soviet occupation. Of the dwellings in multifamily buildings 30 % are assumed to be situated on the first floor. The mean radon concentration in dwellings in detached hoses, according to the survey results, is 103 Bq/m{sup 3}, in dwellings on the bottom floor in multi apartment buildings it is 78 Bq/m{sup 3}. In 1% of the dwellings the radon concentration exceeded 400 Bq/m{sup 3}. The highest radon concentration found in the study was 1040 Bq/m{sup 3}. Based on the assumption that the average radon concentration in the dwellings in multi-apartment buildings that are not situated on the bottom floor is 30 Bq/m{sup 3}, and that these dwellings constitute 70% of all dwellings in multi apartment buildings, the mean radon concentration in dwellings in multi apartment buildings is calculated to be 44 Bq/m{sup 3}. The mean value for all Estonia dwellings is calculated

  9. Radon in Estonian dwellings - Results from a National Radon Survey

    International Nuclear Information System (INIS)

    Pahapill, Lia; Rulkov, Anne; Rajamaee, Raivo; Aakerblom, Gustav

    2003-10-01

    A countrywide survey of radon concentrations in Estonian dwellings was carried out during the period 1998-2001. The survey formed a part of the cooperation program on radiation protection between the Estonian Radiation Protection (Kiirguskeskus) Centre and the Swedish Radiation Protection Authority (SSI). The survey included measurements in a number of dwellings representative for Estonia in detached houses and multifamily buildings (only dwellings on the bottom floor were included in the survey). Altogether, radon concentrations were measured in 515 dwellings, a number large enough to be statistically significant. All measurements were made with alphatrack film detectors of the same type that SSI uses in Sweden. The measurements were made during a 2-3 month period during the winter half-year. Two detectors were used in each dwelling. In Estonia there are 0.17 million dwellings in detached houses and 0.45 million in multi apartment buildings. Of the 1.26 million inhabitants in Estonia. 0.36 million live in detached houses and 0.90 million in multi apartment buildings. Most of the latter were built during the Soviet occupation. Of the dwellings in multifamily buildings 30 % are assumed to be situated on the first floor. The mean radon concentration in dwellings in detached hoses, according to the survey results, is 103 Bq/m 3 , in dwellings on the bottom floor in multi apartment buildings it is 78 Bq/m 3 . In 1% of the dwellings the radon concentration exceeded 400 Bq/m 3 . The highest radon concentration found in the study was 1040 Bq/m 3 . Based on the assumption that the average radon concentration in the dwellings in multi-apartment buildings that are not situated on the bottom floor is 30 Bq/m 3 , and that these dwellings constitute 70% of all dwellings in multi apartment buildings, the mean radon concentration in dwellings in multi apartment buildings is calculated to be 44 Bq/m 3 . The mean value for all Estonia dwellings is calculated to be 60 Bq/m 3 . Using

  10. Radon-film-badges by solid radiators to complement track detector-based radon monitors

    International Nuclear Information System (INIS)

    Tommasino, L.; Tommasino, M.C.; Viola, P.

    2009-01-01

    Existing passive radon monitors, based on track detectors, present many shortcomings, such as a limited response sensitivity for one-week-indoor measurements and a limited response linearity for the assessment of large radon exposures indoors, in thermal spa, in caves, and in soil. Moreover, for in-soil measurements these monitors are too bulky and are often conducive to wrong results. For what concerns the radon-in-water measurements, they are just not suitable. A new generation of passive radon monitors is introduced in this paper, which are very similar to the compact badges used in neutron- and gamma-dosimetry and will be referred to as radon-film-badges. These film-badges are formed by thin-film radiators with suitable radon-sorption characteristics, facing track detectors. The key strategy adopted for these radiators is to exploit an equilibrium type of radon sorption in solids. Even though this new generation of passive monitors is at its infancy, it appears already clear that said monitors make it finally possible to overcome most of the shortcomings of existing passive radon monitors. These devices are uniquely simple and can be easily acquired by any existing radon service to complement their presently used passive radon monitors with little or no effort.

  11. Radon in dwellings in Northern Ireland. 1993 review

    International Nuclear Information System (INIS)

    Green, B.; Lomas, P.; O'Riordan, M.

    1993-01-01

    Measurements of radon made in some 1500 dwellings throughout Northern Ireland by the autumn of 1993 show that the average concentration is 19 Bq m -3 with some values up to fifty times higher. Around 30 of these dwellings are above the Action Level of 200 Bq m -3 adopted by the Government. Data are presented in considerable detail and various forms. Several hundred dwellings in Northern Ireland are estimated to exceed the Action Level, most of which are in a separately designated Affected Area in the southeast. Recommendations are made to promote the discovery and remedy of dwellings above the Action Level throughout Northern Ireland. (author)

  12. Radon in buildings

    International Nuclear Information System (INIS)

    Connell, J.J.

    1991-01-01

    This guide is intended to inform designers, householders and other building owners about the radon problem and to help in deciding if there is need to take any action to reduce radon levels in their homes or other buildings.It explains what radon is, how it enters buildings and what effect it may have on health. Reference is made to some of the usual ways of reducing the level of radon and guidance is given on some sources of assistance

  13. Superfund Record of Decision (EPA Region 2): Montclair/West Orange, Radium, NJ. (First Remedial Action), June 1989

    International Nuclear Information System (INIS)

    1989-01-01

    The Montclair/West Orange Radium site is in the towns of Montclair and West Orange in Essex County, New Jersey. The soil at the site is contaminated with radioactive-waste materials suspected to have originated from radium processing or utilization facilities located nearby during the early 1900s. Temporary radon ventilation systems and gamma-radiation shielding have been installed and maintained by EPA and the State to reduce indoor exposures. The primary contaminant of concern affecting the soil and structures is radium 226 which decays to radon gas. The selected remedial action for the site includes excavation of approximately 41,000 cu yd of highly contaminated soil and an unspecified amount of debris followed by offsite disposal; installation and maintenance of indoor engineering controls at less contaminated properties; environmental monitoring to ensure remedy effectiveness; and continuation of a treatment technology study for future actions. EPA deferred a final continuation of a treatment-technology study for future action

  14. Measurement of radon in air by α track method enhancement detection sensitivity using a lamp

    International Nuclear Information System (INIS)

    Maki, Y.; Tanaka, F.

    1983-01-01

    A new α track method is proposed for the measurement of 222 Rn concentration in environmental levels. This involves collecting radon daughters on the surface of pilot lamp and detecting α-particles emitted from the nuclides ( 218 Po and 214 Po) by a detector (LR 115). The detection sensitivity of this method is 6 times greater than that of the conventional α track method. (author)

  15. Mapping variation in radon potential both between and within geological units

    International Nuclear Information System (INIS)

    Miles, J C H; Appleton, J D

    2005-01-01

    Previously, the potential for high radon levels in UK houses has been mapped either on the basis of grouping the results of radon measurements in houses by grid squares or by geological units. In both cases, lognormal modelling of the distribution of radon concentrations was applied to allow the estimated proportion of houses above the UK radon Action Level (AL, 200 Bq m -3 ) to be mapped. This paper describes a method of combining the grid square and geological mapping methods to give more accurate maps than either method can provide separately. The land area is first divided up using a combination of bedrock and superficial geological characteristics derived from digital geological map data. Each different combination of geological characteristics may appear at the land surface in many discontinuous locations across the country. HPA has a database of over 430 000 houses in which long-term measurements of radon concentration have been made, and whose locations are accurately known. Each of these measurements is allocated to the appropriate bedrock-superficial geological combination underlying it. Taking each geological combination in turn, the spatial variation of radon potential is mapped, treating the combination as if it were continuous over the land area. All of the maps of radon potential within different geological combinations are then combined to produce a map of variation in radon potential over the whole land surface

  16. Uranium City radiation reduction program: further efforts at remedial measures for houses with block walls, concrete porosity test results, and intercomparison of Kuznetz method and Tsivoglau method

    International Nuclear Information System (INIS)

    Haubrich, E.; Leung, M.K.; Mackie, R.

    1980-01-01

    An attempt was made to reduce the levels of radon in a house in Uranium City by mechanically venting the plenums in the concrete block basement walls, with little success. A table compares the results obtained by measuring the radon WL using the Tsivoglau and the Kuznetz methods

  17. Study of the radon released from open drill holes

    International Nuclear Information System (INIS)

    Pacer, J.C.

    1981-06-01

    The radon emanating from three open drill holes was measured at a site of known uranium mineralization in the Red Desert of south central Wyoming. The radon flux from the soil and drill holes was measured by the accumulator method with activated charcoal cartridges. The surface soil was found to release radon at an average rate of 0.41 atoms/cm 2 /sec; the radon emanating from the holes was more variable than that from the soil. The three holes studied released an average of 47 atoms/cm 2 /sec of radon. This average is equivalent to the radon released to the atmosphere by 14.5 ft 2 of soil. The data indicate that the radon emanated from an open drill hole is not as significant as other possible activities at a drill site (i.e. digging a trench or drilling a hole) or from household activities involving the usage of water

  18. Rapid determination of radon daughter concentrations

    International Nuclear Information System (INIS)

    Bigu, J.

    1990-08-01

    A technical evaluation of four radon 222 progeny measuring instruments has been conducted. The evaluation has been carried out under laboratory controlled conditions and at several locations in an underground uranium mine. The laboratory evaluation consisted of a thorough study of the behaviour and performance of the instruments under a wide variety of environmental conditions such as radon 222 gas concentration, radon 222 progeny concentration, temperature, relative humidity, aerosol concentration, and gamma-field exposure. The four instruments tested were: the Pylon WL-1000C, the MDA IWLM-811, the MIMIL IIM, and the EDA WLM-30. The readings of the instruments were compared with a widely accepted radon 222 progeny concentration measuring method, namely, the Thomas-Tsivoglou method. Two variables affected two instruments significantly, namely, under high aerosol concentration conditions, one of the instruments (EDA WLM-30) ceased to operate because of filter loading. The other variable was gamma-field exposure which affected another instrument (MDA-811) adversely. The instruments were rated according to several criteria. The overall best performer was the MIMIL IIM, although other instruments also fared quite well under a variety of experimental conditions

  19. Geotechnical engineering considerations in the NRC's review of uranium mill tailings remedial action plans

    International Nuclear Information System (INIS)

    Gillen, D.M.

    1985-01-01

    To reduce potential health hazards associated with inactive uranium mill tailings sites, the Department of Energy (DOE) is presently investigating and implementing remedial actions at 24 sites in the Uranium Mill Tailings Remedial Action Program (UMTRAP). All remedial actions must be selected and performed with the concurrence of the Nuclear Regulatory Commission (NRC). This paper provides a discussion of geotechnical engineering considerations during the NRC's preconcurrence review of proposed remedial action plans. In order for the NRC staff to perform an adequate geotechnical engineering review, DOE documents must contain a presentation of the properties and stability of all in-situ and engineered soil and rock which may affect the ability of the remedial action plans to meet EPA standards for long-term stability and control. Site investigations, laboratory testing, and remedial action designs must be adequate in scope and technique to provide sufficient data for the NRC staff to independently evaluate static and dynamic stability, settlement, radon attenuation through the soil cover, durability of rock for erosion protection, and other geotechnical engineering factors

  20. Radon reduction

    International Nuclear Information System (INIS)

    Hamilton, M.A.

    1990-01-01

    During a radon gas screening program, elevated levels of radon gas were detected in homes on Mackinac Island, Mich. Six homes on foundations with crawl spaces were selected for a research project aimed at reducing radon gas concentrations, which ranged from 12.9 to 82.3 pCi/l. Using isolation and ventilation techniques, and variations thereof, radon concentrations were reduced to less than 1 pCi/l. This paper reports that these reductions were achieved using 3.5 mil cross laminated or 10 mil high density polyethylene plastic as a barrier without sealing to the foundation or support piers, solid and/or perforated plastic pipe and mechanical fans. Wind turbines were found to be ineffective at reducing concentrations to acceptable levels. Homeowners themselves installed all materials

  1. Radon generation and transport. A journey though matter

    Energy Technology Data Exchange (ETDEWEB)

    Cozmuta, I. [Beckman Institute 139-74 Caltech, Pasadena, CA 91125 (United States)

    2001-12-07

    The transport of radon in concrete takes place through the complicated network of interconnected pores that is, at any time, the result of the process of hydration of cement and of moisture distribution and transport. Initially the microstructure of concrete depends on the mix proportions and curing conditions, its time-evolution being conditioned by its surrounding environment. Radon transport will be consequently a function of time, as it is influenced by the changing microstructure (total porosity and its distribution) and by the amount and distribution of the moisture contained in the pore system. A selection of information from the large amount of literature available on concrete is presented in chapter 2. A model that describes the process of hydration, of microstructure development and of moisture transport is presented in chapter 3. The physics of radon diffusion in homogeneous porous materials is outlined in chapter 4. The coupling of the numerical implementation of the hydration and radon transport (chapter 6) offers the possibility to achieve calculated values for porosity and moisture content thus, reducing the number of material parameters in the radon-transport equation that have to be determined experimentally. Chapter 7 covers the experimental methods and techniques. Chapter 5 presents a survey of the information available in literature on radon release from concrete and on radon barriers. This chapter also summarises results of several experimental studies investigating the radon reduction efficiency and also the permeability of various covers. On basis of this information, a selection was made for the covering materials to be assessed in this thesis. Radon-release rates of uncovered and completely covered concrete samples were measured. From these measurements the reduction efficiencies of various sealants (epoxy glue, double-sided aluminised polyethylene foil, soluble glass) were calculated (chapter 12). Also, as a result of the collaboration

  2. Radon generation and transport. A journey though matter

    International Nuclear Information System (INIS)

    Cozmuta, I.

    2001-01-01

    The transport of radon in concrete takes place through the complicated network of interconnected pores that is, at any time, the result of the process of hydration of cement and of moisture distribution and transport. Initially the microstructure of concrete depends on the mix proportions and curing conditions, its time-evolution being conditioned by its surrounding environment. Radon transport will be consequently a function of time, as it is influenced by the changing microstructure (total porosity and its distribution) and by the amount and distribution of the moisture contained in the pore system. A selection of information from the large amount of literature available on concrete is presented in chapter 2. A model that describes the process of hydration, of microstructure development and of moisture transport is presented in chapter 3. The physics of radon diffusion in homogeneous porous materials is outlined in chapter 4. The coupling of the numerical implementation of the hydration and radon transport (chapter 6) offers the possibility to achieve calculated values for porosity and moisture content thus, reducing the number of material parameters in the radon-transport equation that have to be determined experimentally. Chapter 7 covers the experimental methods and techniques. Chapter 5 presents a survey of the information available in literature on radon release from concrete and on radon barriers. This chapter also summarises results of several experimental studies investigating the radon reduction efficiency and also the permeability of various covers. On basis of this information, a selection was made for the covering materials to be assessed in this thesis. Radon-release rates of uncovered and completely covered concrete samples were measured. From these measurements the reduction efficiencies of various sealants (epoxy glue, double-sided aluminised polyethylene foil, soluble glass) were calculated (chapter 12). Also, as a result of the collaboration

  3. Radon measurement studies in Kazakhstan

    International Nuclear Information System (INIS)

    Sevost'yanov, V.N.

    2003-01-01

    Today, one has to admit that despite the important role and certain achievements in providing the radiation control in Kazakhstan, radon measurements still present some problems related to clear definition of physical quantities applied, correct use of methods, and application of adequate measuring devices to meet requirements of regulatory documents currently in effect, such as NRB-99. The paper provides some data on radon measurements, describes the problem status in Kazakhstan and proposes ways to solve it. (author)

  4. Radon in workplaces and schools in Hungary and Japan

    International Nuclear Information System (INIS)

    Nemeth, Csaba; Tokonami, Shinji; Ishikawa, Tetsuo

    2005-01-01

    Reacting upon the increasing concern of possible harmful effects due to radon, more and more countries established, or intend to establish in the near future, legislation for the radon level both for homes and workplaces. The dose due to radon seems to be more complicated to assess for workplaces than for homes, although the basic principles of dose estimation are the same. The doses at workplaces need to be estimated by individual approaches, but such requirement is usually not reflected in the legislations. The present study deals with characteristic situations and refers to findings and considerations in the cases of offices, schools, underground workplaces, and open air working situations with relatively high radon level. It discusses the possible inaccuracies caused by the improper selection of time periods and methods in the measurements of the average radon concentration. The purpose of this paper is to provide some examples (mainly based on the authors' experiences) to show difficulties that might emerge in the determination of average radon concentrations in various workplaces. This will help choose the proper measurement methods for each case and contribute to the regulator's work in the precise and unambiguous legislation phrasing. (author)

  5. Radon level and radon effective dose rate determination in Moroccan dwellings using SSNTDs

    International Nuclear Information System (INIS)

    Oufni, L.; Misdaq, M.A.; Amrane, M.

    2005-01-01

    Inhalation of radon ( 222 Rn) and its daughter product are a major source of natural radiation exposure. The measurement of radon activity in dwelling is assuming ever increasing importance. It is known from recent surveys in many countries that radon and its progeny contribute significantly to total inhalation dose and it is fairly established that radon when inhaled in large quantity causes lung disorder. Keeping this in view, the indoor radon activity level and radon effective dose rate were carried out in the dwellings of Beni-Mellal, Khouribgra and Ben Guerir cities, Morocco, using the solid state nuclear track detectors (SSNTD) technique. Assuming an indoor occupancy factor of 0.8 and 0.4 for the equilibrium factor of radon indoors, we found that the 222 Rn effective dose rate in the studied dwellings ranges from 1.01 to 7.90mSvy -1 . The radon activity in the corresponding dwellings was found to vary from 40 to 532Bqm -3 . The radon activity has not only been found to vary with seasonal changes, but also with the age, the construction mode of houses, the ventilation conditions and with specific sites and geological materials

  6. Indoor radon and childhood leukaemia

    International Nuclear Information System (INIS)

    Raaschou-Nielsen, O.

    2008-01-01

    This paper summarises the epidemiological literature on domestic exposure to radon and risk for childhood leukaemia. The results of 12 ecological studies show a consistent pattern of higher incidence and mortality rates for childhood leukaemia in areas with higher average indoor radon concentrations. Although the results of such studies are useful to generate hypotheses, they must be interpreted with caution, as the data were aggregated and analysed for geographical areas and not for individuals. The seven available case - control studies of childhood leukaemia with measurement of radon concentrations in the residences of cases and controls gave mixed results, however, with some indication of a weak (relative risk < 2) association with acute lymphoblastic leukaemia. The epidemiological evidence to date suggests that an association between indoor exposure to radon and childhood leukaemia might exist, but is weak. More case - control studies are needed, with sufficient statistical power to detect weak associations and based on designs and methods that minimise misclassification of exposure and provide a high participation rate and low potential selection bias. (authors)

  7. Radon atlas of Finland

    International Nuclear Information System (INIS)

    Voutilainen, A.; Maekelaeinen, I.; Pennanen, M.; Reisbacka, H.; Castren, O.

    1997-11-01

    The most efficient means of reducing indoor radon exposure is to locate and mitigate dwellings with radon concentration exceeding the action level of 400 Bq/m 3 and to build new houses so that radon concentrations do not exceed 200 Bq/m 3 . The maps and tables in this report are useful tools for those who plan and decide what kind of radon mitigation measures are needed in municipalities. STUK (The Radiation and Nuclear Safety Authority) has an indoor radon database of 52 000 dwellings, for which the indoor radon concentration and construction details are known. The building site soil type of about 38 000 dwellings is known. This atlas is a summary of all indoor radon measurements made by STUK in lowrise dwellings and in first-floor flats. The results are shown as arithmetic means of 5- or 10-km squares on maps of the provinces. Three radon maps have been made for each province. On one map the data consist of all measurements the position coordinates of which are known. On the two other maps the building sites of houses are classified into permeable and low-permeable soil types. The tables show statistics for all indoor radon measurements by municipality and building site soil type. (orig.)

  8. Scopingreport radon

    International Nuclear Information System (INIS)

    Blaauboer, R.O.; Vaas, L.H.; Hesse, J.M.; Slooff, W.

    1989-09-01

    This report contains general information on radon concerning the existing standards, sources and emissions, the exposure levels and effect levels. lt serves as a basis for the discussion during the exploratory melting to be held in November/December 1989, aimed at determining the contents of the Integrated Criteria Document Radon. Attention is focussd on Rn-222 (radon) and Rn-220 (thoron), presently of public interest because of radon gas pollution in private homes. In the Netherlands air quality standards nor product standards for the exhalation rate of building materials have been recommended. The major source of radon in the Netherlands is the soil gas (> 97%), minor sources are phosphate residues and building materials (> 2% in total). Hence, the major concern is the transfer through the inhalation of air, the lung being the most critical organ at risk to develop cancer. Compared to risks for humans, the risks of radon and its daughters for aquatic and terrestric organisms, as well as for agricultural crops and livestock, are assumed to be limited. In the Netherlands the average dose for man due to radon and thoron progeny is appr. 1.2 mSv per year, the estimated dose range being 0.1-3.5 mSv per year. This dose contributes for about 50% to rhe total exposure due to all sources of ionizing radiation. Of this dose respectively 80% is caused by radon and about 90% is received indoor. The estimated dose for the general population corresponds to a risk for inducing fatal cancers of about 15 x 10-6 per year, ranging from 1.2 x 10-6 to 44 x 10-6 which exceeds the risk limit of 1 x 10-6 per year -as defined in the standardization policy in the Netherlands for a single source of ionizing radiation-with a factor 15 (1- 44). Reduction of exposure is only possible in the indoor environment. Several techniques have been described to reduce the indoor dose, resulting from exhalation of the soil and building materials. )aut- hor). 37 refs.; 3 figs.; 8 tabs

  9. Measurement of indoor radon concentration by CR-39 track detector

    International Nuclear Information System (INIS)

    Yamamoto, Masayoshi; Yoneda, Shigeru; Nakanishi, Takashi.

    1990-01-01

    A convenient and cheap method for measuring indoor radon ( 222 Rn) concentration with a CR-39 track detector is described. The detector consisted of two sheets of CR-39 enclosed separately in two plastic pots : one covered by a filter (cup method) and another no covering (bare method). The bare method was used here to supplement the cup method. To compare with the result of the CR-39 detector, alpha-ray spectrometry was carried out with a Si(Au) detector in a controlled radon exposure chamber. Indoor radon concentration measured in 133 houses in several districts of Ishikawa Prefecture have been found to range from 6 Bq/m 3 to as high as 113 Bq/m 3 with a median value of 24 Bq/m 3 . The problems to measure indoor radon concentration using the CR-39 detector are also discussed with emphasis on the position of setting the detector in the room and the possible thoron contribution to the detector. (author)

  10. Monitoring employee exposure to radon and its daughters in uranium mines

    International Nuclear Information System (INIS)

    Leach, V.A.; Lokan, K.H.

    1979-06-01

    Practical methods for measuring the concentration in air of radon and radon daughter are reviewed, and straightforward procedures are described for reliable field measurements. Typical field data, and sample calculations are provided, together with suitable procedures for calculating and reporting cumulative radon daughter exposures

  11. The Correlation between Radon Emission Concentration and Subsurface Geological Condition

    Science.gov (United States)

    Kuntoro, Yudi; Setiawan, Herru L.; Wijayanti, Teni; Haerudin, Nandi

    2018-03-01

    Exploration activities with standard methods have already encountered many obstacles in the field. Geological survey is often difficult to find outcrop because they are covered by vegetation, alluvial layer or as a result of urban development and housing. Seismic method requires a large expense and licensing in the use of dynamite is complicated. Method of gravity requires the operator to go back (looping) to the starting point. Given some of these constraints, therefore it needs a solution in the form of new method that can work more efficiently with less cost. Several studies in various countries have shown a correlation between the presence of hydrocarbons and Radon gas concentration in the earth surface. By utilizing the properties of Radon that can migrate to the surface, the value of Radon concentration in the surface is suggested to provide information about the subsurface structure condition. Radon is the only radioactive substance that gas-phased at atmospheric temperature. It is very abundant in the earth mantle. The vast differences of temperatures and pressures between the mantle and the earth crust cause the convection flow toward earth surface. Radon in gas phase will be carried by convection flow to the surface. The quantity of convection currents depend on the porosity and permeability of rocks where Radon travels within, so that Radon concentration in the earth surface delineates the porosity and permeability of subsurface rock layers. Some measurements were carried out at several locations with various subsurface geological conditions, including proven oil fields, proven geothermal field, and frontier area as a comparison. These measurements show that the average and the background concentration threshold in the proven oil field (11,200 Bq/m3) and proven geothermal field (7,820 Bq/m3) is much higher than the quantity in frontier area (329 and 1,620 Bq/m3). Radon concentration in the earth surface is correlated with the presence of geological

  12. Radon-222 exhalation and its variation in soil air

    International Nuclear Information System (INIS)

    Mochizuki, S.; Sekikawa, T.

    1980-01-01

    A new method has been designed and developed for measuring the concentration of radon in soil air without disturbing the natural condition of the soil. By this method, radon concentrations in the soil air at various points down to a depth of 1 m below the ground are obtained from the concentrations of radium A ( 218 Po) measured in the same air. The radium A concentration is measured by spectrometry of alpha particles from radioactive ions in the soil air. The basic experiments and preliminary observations made in the soil air below the ground confirmed the usefulness of the newly constructed apparatus for measuring the radon concentration in the soil air. Our preliminary observations showed that the radon concentration in the soil air near the surface of the earth varied remarkably before heavy thunderstorms

  13. Design Criteria for Achieving Acceptable Indoor Radon Concentration

    DEFF Research Database (Denmark)

    Rasmussen, Torben Valdbjørn

    2016-01-01

    Design criteria for achieving an acceptable indoor radon concentration are presented in this paper. The paper suggests three design criteria. These criteria have to be considered at the early stage of the building design phase to meet the latest recommendations from the World Health Organization...... in most countries. The three design criteria are; first, establishing a radon barrier facing the ground; second, lowering the air pressure in the lower zone of the slab on ground facing downwards; third, diluting the indoor air with outdoor air. The first two criteria can prevent radon from infiltrating...... from the ground, and the third criteria can dilute the indoor air. By combining these three criteria, the indoor radon concentration can be lowered achieving an acceptable level. In addition, a cheap and reliable method for measuring the radon concentration in the indoor air is described. The provision...

  14. U.S. Postal Service radon assessment and mitigation program. Progress report, September 1993--November 1994

    Energy Technology Data Exchange (ETDEWEB)

    Velazquez, L.E.; Petty, J.L. Jr.

    1994-12-31

    In 1992, the US Postal Service (USPS) entered into an Interagency Agreement with the Department of Energy (DOE) whereby DOE would provide technical assistance in support of the USPS Radon Assessment and Mitigation Program. To aid in this effort, DOE tasked the Hazardous Waste Remedial Actions Program (HAZWRAP), which is managed by Martin Marietta Energy Systems, Inc., for DOE under contract AC05-84OR21400. Since that time, HAZWRAP has developed and finalized the sampling protocol, mitigation diagnostic protocol, and the quality assurance and quality control procedures. These procedures were validated during the Protocol Validation (1992-1993) and Pilot Study (1993-1994) phases of the program. To date, HAZWRAP has performed approximately 16,000 radon measurements in 250 USPS buildings. Mitigation diagnostics have been performed in 27 buildings. Thus far, 13% of the measurements have been above the Environmental Protection Agency action level of 4 pCi/L. This report summarizes the pilot program radon testing data and mitigation diagnostic data for 22 sites and contains recommendations for mitigation diagnostics.

  15. U.S. Postal Service radon assessment and mitigation program. Progress report, September 1993--November 1994

    International Nuclear Information System (INIS)

    Velazquez, L.E.; Petty, J.L. Jr.

    1994-01-01

    In 1992, the US Postal Service (USPS) entered into an Interagency Agreement with the Department of Energy (DOE) whereby DOE would provide technical assistance in support of the USPS Radon Assessment and Mitigation Program. To aid in this effort, DOE tasked the Hazardous Waste Remedial Actions Program (HAZWRAP), which is managed by Martin Marietta Energy Systems, Inc., for DOE under contract AC05-84OR21400. Since that time, HAZWRAP has developed and finalized the sampling protocol, mitigation diagnostic protocol, and the quality assurance and quality control procedures. These procedures were validated during the Protocol Validation (1992-1993) and Pilot Study (1993-1994) phases of the program. To date, HAZWRAP has performed approximately 16,000 radon measurements in 250 USPS buildings. Mitigation diagnostics have been performed in 27 buildings. Thus far, 13% of the measurements have been above the Environmental Protection Agency action level of 4 pCi/L. This report summarizes the pilot program radon testing data and mitigation diagnostic data for 22 sites and contains recommendations for mitigation diagnostics

  16. Calibration of SSNDT detectors for radon measurements

    International Nuclear Information System (INIS)

    Takahashi, Laura C.; Santos, Talita O.; Pinheiro, Rose Mary M.; Rocha, Zildete

    2017-01-01

    The methods and instrumentation used to measure the concentration of radon need to be calibrated to obtain accurate results. The Nuclear Track Detector is considered the main method of analysis of radon research. Thus, the Natural Radioactivity Laboratory of the Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG, Brazil) uses the detector CR-39 (Landauer) to measure the concentration of radon in homes, workplaces, underground mines, soils and in environment. Epidemiological studies reveal the strong relationship between lung cancer and radon exposure. Therefore, it is important to monitor this gas and its progeny in order to assess the radiological risk. The alpha particles emitted by radon and its progeny leave traces on CR-39 due to Coulombian interactions with the atoms of the material. The liquid density of traces is converted to radon concentration by means of a calibration factor obtained in calibrated systems. This work aims to determine the LRN / CDTN calibration factor. To do so, the CR-39 detectors were placed inside the calibration chambers, along with two AlphaGUARD (Saphymo GmbH) detectors and Ra-266 sources with activities of 3,379 kBq or 0.483 kBq, referenced by NIST. From this, six levels of exposure were obtained, which were: 44 kBq.d.m 3 , 4 kBq.d.m 3 , 3 kBq.d.m 3 , 15 kBq.d.m 3 , 30 kBq.d.m 3 , 26 kBq.d.m 3 . The conversion factor between the liquid density of traces and the total exposure time obtained was K = 52.028 ± 0.752 [(trace density.cm -2 ) / (kBq.d.m -3 )]. After the determination of the conversion factor, it was used to measure the concentration of radon in underground mines, obtaining concentration results between 122 ± 24 and 7384 ± 517 kBq.m -3

  17. The effect of natural ventilation on radon and radon progeny levels in houses

    International Nuclear Information System (INIS)

    Cavallo, A.; Gadsby, K.; Reddy, T.A.; Socolow, R.

    1992-01-01

    In contradiction to the widely held assumption that ventilation is ineffective as a means of reducing indoor radon concentrations, experiments in a research house have shown that the basement radon level can be reduced by a factor of 5-10 using only natural ventilation. Measurements of the outdoor-basement pressure differential and the radon entry rate show that this unexpectedly large reduction in indoor radon levels is caused by two complementary physical processes. The first mechanism is the obvious one: dilution. Radon concentrations are lowered by the addition of uncontaminated outdoor air. The second mechanism is less evident: an open basement window reduces basement depressurisation. This decreases the rate at which radon-laden soil gas is drawn into the house. It was also found that the radon entry rate is a linear function of basement depressurisation up to a differential pressure of about 4 Pa, as would be expected for laminar soil gas flow; opening two basement windows approximately doubles the building air exchange rate and reduces the radon entry rate by up to a factor of 5. (author)

  18. Definition of correcting factors for absolute radon content measurement formula

    International Nuclear Information System (INIS)

    Ji Changsong; Xiao Ziyun; Yang Jianfeng

    1992-01-01

    The absolute method of radio content measurement is based on thomas radon measurement formula. It was found in experiment that the systematic error existed in radon content measurement by means of thomas formula. By the analysis on the behaviour of radon daughter five factors including filter efficiency, detector construction factor, self-absorbance, energy spectrum factor, and gravity factor were introduced into the thomas formula, so that the systematic error was eliminated. The measuring methods of the five factors are given

  19. Environmental remediation for the upstream of Yotsugi Mill Tailings Pond, Ningyo-toge Uranium Mine

    International Nuclear Information System (INIS)

    Saito, Hiroshi; Torikai, Kazuyoshi; Fukushima, Shigeru; Sakao, Ryota; Taki, Tomihiro; Sato, Yasushi; Sakamoto, Atsushi

    2016-03-01

    Ningyo-toge Environmental Engineering Center has been conducting environmental remediation of the Ningyo-toge Uranium Mine, after decades of mine-related activities including uranium exploration, mining and test milling were terminated. The main purposes of the remediation are to take measures to ensure safety and radiation protection from the exposure pathways to humans in future, and to prevent the occurrence of mining pollution. As part of the remediation, upstream part of the Yotsugi Mill Tailings Pond, the highest prioritized facility among all of the mine-related facilities, has been remediated to fiscal year 2012. In the remediation, multi-layered capping has been constructed using natural material on ground surface, after specifications and whole remediation procedure being examined in terms of long-term stability, radiation protection, economics, and other aspects. Monitoring has been carried out to confirm the effectiveness of the capping, in terms of settlement, underground temperature, dose-rate and radon exhalation rate. Monitoring of drainage volume of penetrated rainwater is planned to begin in future. Accumulated data will be examined and its result will be used for remediation of downstream part of the Pond. (author)

  20. Orphan radon daughters at Denver Radium site

    International Nuclear Information System (INIS)

    Holub, R.F.; Droullard, R.F.; Davis, T.H.

    1992-01-01

    During 18 mo of sampling airborne radioactively at a National Priority List (open-quotes Superfundclose quotes) site in metroPOlitan Denver, Bureau of mines personnel discovered radon daughters that are not supported by the parent radon gas. We refer to them as open-quotes orphanclose quotes daughters because the parent, radon, is not present in sufficient concentration to support the measured daughter products. Measurements of the open-quotes orphanclose quotes daughters were made continuously, using the Bureau-developed radon and working-level (radon-daughter) monitors. The data showed high equilibrium ratios, ranging from 0.7 to 3.5, for long periods of time. Repeated, high-volume, 15-min grab samples were made, using the modified Tsivoglou method, to measure radon daughters, to which thoron daughters contributed 26 ± 12%. On average 28 ± 6% of the particulate activity was contributed by thoron daughters. Most samples were mixtures in which the 218 Po concentration was lower than that of 214 Pb and 214 Bi, in agreement with the high-equilibrium factors obtained from the continuous sampling data. In view of the short half-life of radon progeny, we conclude that the source of the orphan daughters is not far from the Superfund sites. The mechanism of this phenomenon is not understood at this time, but we will discuss its possible significance in evaluating population doses